Sample records for conventional continuous prolene

  1. [The use of a prolene double mesh for orbital wall reconstruction].

    PubMed

    Junceda-Moreno, J; Suárez-Suárez, E; Dos-Santos-Bernardo, V

    2005-08-01

    Patient with a recurrent carcinoma of the nasal fossae affecting the internal orbital wall. The intraorbital content was not affected. The orbital wall was reconstructed with a prolene double mesh anchored to the periosteum. Prolene mesh as a substitute of the orbital wall. Good stability and isolation of the intraorbital structures were observed. Ocular motility was completely normal after surgery without prolene mesh displacements. The prolene double mesh is a good surgical option to replace missing bone in the reconstruction of the internal orbital wall.

  2. Endoscopic dacryocystorhinostomy with silicone, polypropylene, and T-tube stents; randomized controlled trial of efficacy and safety.

    PubMed

    Okuyucu, Semsettin; Gorur, Hatice; Oksuz, Huseyin; Akoglu, Ertap

    2015-01-01

    To compare the efficacy and safety of endoscopic dacryocystorhinostomy (En-DCR) with different stent materials for lacrimal sac intubation in primary nasolacrimal ductal obstructions. Randomized controlled study with three parallel groups. Level of evidence is 1b. A total of 91 patients (five bilateral) with primary nasolacrimal duct obstruction (NLDO) at a tertiary referral center scheduled for En-DCR were to allocated into three stent groups with a sealed envelope and were randomized into three treatments: silicone, Prolene (polypropylene), and otologic T-tube. Ophthalmology and otolaryngology clinics evaluated the patients preoperatively and postoperatively with endoscopes, lacrimal system syringing, and dacryocystography. The success of the stents was evaluated 12 months after surgery with symptom relief and ostial patency. Complications were also noted. The overall success rate of the En-DCR in the stent groups was 78.1% (75/96); specifically, 87.5% (28/32) with silicone, 84.4% (27/32) with Prolene, and 62.5% (20/32) with T-tube. The efficacy of the procedures with the T-tube was significantly lower than that of the Prolene and silicone (p = .031, χ(2) test). There were no significant differences between the silicone and Prolene (p = .718, χ(2) test). Prolene was found to be related with orbital complications. Spontaneous loss is a particular complication of otologic T-tube and highly portends to failure. The results of our study suggest that efficacy, defined as anatomic and functional success, is equally high for silicone and Prolene stents and lower for otologic T-tube in En-DCR.

  3. Donor-site morbidity after pedicled TRAM breast reconstruction: a comparison of two different types of mesh.

    PubMed

    Sværdborg, Mille; Damsgaard, Tine Engberg

    2013-11-01

    Many different approaches have been used to minimize the risk of bulge or hernia formation when using autologous abdominal tissue for breast reconstruction. Studies have shown that further reinforcement of the abdominal wall using a mesh may decrease the complication rate.The current study included 40 consecutive patients having unilateral breast reconstruction with the pedicled transverse rectus abdominus musculocutaneous flap. The defect in the abdominal fascia was closed primarily and further reinforced using a Prolene mesh (Ethicon), n = 20, or using a self-fixating Parietex ProGrip mesh (Covidien), n = 20. The patients were examined at an outpatient consultation, with a minimum follow-up of 1 year and questioned about donor-site symptoms using a standardized questionnaire.Of the 20 patients in the Prolene group, 2 (10%) developed abdominal wall bulging, and of the 20 patients in the ProGrip group, 11 (55%) developed abdominal wall bulging (P = 0.006). In both the Prolene and the ProGrip group, most patients reported having continued donor-site symptoms at the time of the follow-up (70% and 80%, respectively); 15% and 30%, respectively, reported having symptoms that influenced their daily or physical activities (not a significant difference). All but 1 patient in our study reported being very happy with the reconstruction and would have done it again, had they known what they did at the time of the follow-up.We conclude that the self-gripping properties of the Parietex ProGrip mesh are not sufficient in withstanding the abdominal wall tension at the donor site after transverse rectus abdominus musculocutaneous-flap harvest and do not recommend using the Parietex ProGrip mesh without fixating sutures for this procedure.

  4. Reconstruction of chest wall using a two-layer prolene mesh and bone cement sandwich.

    PubMed

    Aghajanzadeh, Manouchehr; Alavi, Ali; Aghajanzadeh, Gilda; Ebrahimi, Hannan; Jahromi, Sina Khajeh; Massahnia, Sara

    2015-02-01

    Wide surgical resection is the most effective treatment for the vast majority of chest wall tumors. This study evaluated the clinical success of chest wall reconstruction using a Prolene mesh and bone cement prosthetic sandwich. The records of all patients undergoing chest wall resection and reconstruction were reviewed. Surgical indications, the location and size of the chest wall defect, diaphragm resection, pulmonary performance, postoperative complications, and survival of each patient were recorded. From 1998 to 2008, 43 patients (27 male, 16 female; mean age of 48 years) underwent surgery in our department to treat malignant chest wall tumors: chondrosarcoma (23), osteosarcoma (8), spindle cell sarcoma (6), Ewing's sarcoma (2), and others (4). Nine sternectomies and 34 antero-lateral and postero-lateral chest wall resections were performed. Postoperatively, nine patients experienced respiratory complications, and one patient died because of respiratory failure. The overall 4-year survival rate was 60 %. Chest wall reconstruction using a Prolene mesh and bone cement prosthetic sandwich is a safe and effective surgical procedure for major chest wall defects.

  5. Stress-relaxation and fatigue behaviour of synthetic brow-suspension materials.

    PubMed

    Kwon, Kyung-Ah; Shipley, Rebecca J; Edirisinghe, Mohan; Rayment, Andrew W; Best, Serena M; Cameron, Ruth E; Salam, Tahrina; Rose, Geoffrey E; Ezra, Daniel G

    2015-02-01

    Ptosis describes a low position of the upper eyelid. When this condition is due to poor function of the levator palpebrae superioris muscle, responsible for raising the lid, "brow-suspension" ptosis correction is usually performed, which involves internally attaching the malpositioned eyelid to the forehead musculature using brow-suspension materials. In service, such materials are exposed to both rapid tensile loading and unloading sequences during blinking, and a more sustained tensile strain during extended periods of closure. In this study, various mechanical tests were conducted to characterise and compare some of commonly-used synthetic brow-suspension materials (Prolene(®), Supramid Extra(®) II, Silicone rods (Visitec(®) Seiff frontalis suspension set) and Mersilene(®) mesh) for their time-dependent response. At a given constant tensile strain or load, all of the brow-suspension materials exhibited stress-relaxation or creep, with Prolene(®) having a statistically different relaxation or creep ratio as compared with those of others. Uniaxial tensile cyclic tests through preconditioning and fatigue tests demonstrated drastically different time-dependent response amongst the various materials. Although the tests generated hysteresis force-strain loops for all materials, the mechanical properties such as the number of cycles required to reach the steady-state, the reduction in the peak force, and the cyclic energy dissipation varied considerably. To reach the steady-state, Prolene(®) and the silicone rod required the greatest and the least number of cycles, respectively. Furthermore, the fatigue tests at physiologically relevant conditions (15% strain controlled at 6.5 Hz) demonstrated that the reduction in the peak force during 100,000 cycles ranged from 15% to 58%, with Prolene(®) and the silicone rod exhibiting the greatest and the least value, respectively. Many factors need to be considered to select the most suitable brow-suspension material for ptosis correction. These novel data on the mechanical time-dependent performance could therefore help to guide clinicians in their decision-making process for optimal surgical outcome. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Laparoscopic mesh fixation using laser-assisted tissue soldering in a porcine model.

    PubMed

    Lanzafame, Raymond J; Soltz, Barbara A; Stadler, Istvan; Soltz, Robert

    2009-01-01

    Animal studies using open surgical models indicate that collagen solder is capable of fixation of surgical meshes without interfering with tissue integration, increasing adhesions, or increasing inflammation intraperitoneally. This study describes development of instrumentation and techniques for laparoscopic herniorrhaphy using laser-assisted soldering technology. Anesthetized 20 kg to 25 kg female Yorkshire pigs underwent laparoscopy with a 3-trocar technique. Parietex TET, Parietex TEC, and Prolene mesh segments (5 x 5 cm) were embedded in 55% collagen solder. Segments were inserted by using a specially designed introducer and affixed to the peritoneum by using prototype laser devices (1.45 micro, 4.5 W continuous wave, 5-mm spot, 55 degrees C set temperature) and a custom laparoscopic handpiece (IPOM). Parietex PCO mesh was inserted and affixed using the Endo-hernia stapler (Control). Animals were recovered and underwent second-look laparoscopy at 6 weeks. Mesh sites were harvested after animals were euthanized. The mesh-solder constructs were easily inserted and affixed in an IPOM approach. Prolene mesh tended to curl at its edges as the solder was melted. Postoperative healing was similar to that in Control segments in all cases. Collagen-based tissue soldering permits normal wound healing and may mitigate or reduce the use of staples or other foreign bodies for laparoscopic mesh fixation, prevent tissue ischemia and possibly nerve entrapment, which result in severe postoperative pain and morbidity. Laser-assisted mesh fixation is a promising alternative for laparoscopic herniorrhaphy. Further development of this strategy is warranted.

  7. Meta-analysis of Prolene Hernia System mesh versus Lichtenstein mesh in open inguinal hernia repair.

    PubMed

    Sanjay, Pandanaboyana; Watt, David G; Ogston, Simon A; Alijani, Afshin; Windsor, John A

    2012-10-01

    This study was designed to systematically analyse all published randomized clinical trials comparing the Prolene Hernia System (PHS) mesh and Lichtenstein mesh for open inguinal hernia repair. A literature search was performed using the Cochrane Colorectal Cancer Group Controlled Trials Register, the Cochrane Central Register of Controlled Trials in the Cochrane Library, MEDLINE, Embase and Science Citation Index Expanded. Randomized trials comparing the Lichtenstein Mesh repair (LMR) with the Prolene Hernia System were included. Statistical analysis was performed using Review Manager Version 5.1 software. The primary outcome measures were hernia recurrence and chronic pain after operation. Secondary outcome measures included surgical time, peri-operative complications, time to return to work, early and long-term postoperative complications. Six randomized clinical trials were identified as suitable, containing 1313 patients. There was no statistical difference between the two types of repair in operation time, time to return to work, incidence of chronic groin pain, hernia recurrence or long-term complications. The PHS group had a higher rate of peri-operative complications, compared to Lichtenstein mesh repair (risk ratio (RR) 0.71, 95% confidence interval 0.55-0.93, P=0.01). The use of PHS mesh was associated with an increased risk of peri-operative complications compared to LMR. Both mesh repair techniques have comparable short- and long-term outcomes. Copyright © 2012 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  8. Ontogeny of a surgical technique: Robotic kidney transplantation with regional hypothermia.

    PubMed

    Sood, Akshay; McCulloch, Peter; Dahm, Philipp; Ahlawat, Rajesh; Jeong, Wooju; Bhandari, Mahendra; Menon, Mani

    2016-01-01

    Innovation is a hallmark of surgical practice. It is generally accepted that a new procedure will undergo technical changes during its evolution; however, quantitative accounts of the process are limited. Multiple groups, including our own, have recently described a minimally-invasive approach to conventional kidney transplantation (KT) operation. Unique to our experience is a structured development of the technique within the confines of a safe surgical innovation framework - the IDEAL framework (idea, development, exploration, assessment, long-term monitoring; stages 0-4). We here provide a first-hand narrative of the progress of robotic KT operation from preclinical trial to clinical application. Overall, 54 patients underwent robotic KT with regional hypothermia successfully. Major technical changes including selection of optimal patient position (flank vs. lithotomy), robotic instrumentation, vascular occlusion method (bulldog vs. tourniquet) and suture material (prolene vs. GoreTex) occurred early during the procedure development (IDEAL stage 0, preclinical). Minor technical changes such as utilization of the aortic punch for arteriotomy (case 3), use of barbed suture during ureteroneocystostomy (case 6) and extraperitonealization of the graft kidney (case 6) that increased the efficiency and safety of the procedure continued throughout procedure development (IDEAL stages 1-2, clinical stages). We demonstrate that a surgical technique evolves continually; although, the majority of technical alterations occur early in the life-cycle of the procedure. Development of a new technique within the confines a structured surgical innovation framework allows for evidence based progression of the technique and may minimize the risk of harm to the patient. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  9. [Development of better tolerated prosthetic materials: applications in gynecological surgery].

    PubMed

    Debodinance, P; Delporte, P; Engrand, J B; Boulogne, M

    2002-10-01

    Meshes have come to be widely used for surgical repair of the dysfunctional pelvic floor. The problem to date has been mesh intolerance. History. The first meshes were made with silver filigrees or stainless steel. Non-metallic and non-absorbable synthetic prostheses include nylon, silastic, polytetrafluoroethylene as well as expansive polyester and polypropylene forms. Most of the absorbable prostheses are made of polyglycolic acid and polyglactine 910. Classification. Four groups of biomaterials can be described according to pore size. Mechanical and biological properties. The mechanical properties of meshes have been tested industrially for resistance, pliability, elasticity and ductile qualities. These properties depend on type of tissue structure (woven or knitted) and the type of fiber used (mono and multi-filaments). The goal is to obtain a "silent" material, i.e. a material which does not trigger a host tissue reaction. Introducing the foreign body induces a "scarring" response. This fibroblastic reaction replaces the inflammatory reaction, leading to progressive colonization of the prosthesis. The major risk is infection caused by a disturbance of the inflammatory phase and bacterial development. Bacteria can be trapped in fibrotic tissue, with the risk of delayed infection. Immunological reactions may have an additive effect. These problems are not encountered with absorbable meshes. An ideal implant material must: not undergo physical modification by tissue fluids, be chemically inert, not trigger inflammatory or foreign body cell response in body tissues, be noncarcinogenic and nonallergenic, be capable of resisting mechanical stress and sterilization, and be able to be manufactured in the necessary shape. Polyester, polypropylene and expansive polytetrafluoroethylene fulfill these criteria. The ideal mesh. Eleven criteria are proposed. Complications for hernia repair. Infection and seroma are the most frequent complications with micro-porous meshes. Macro-porous meshes can cause erosive phenomena and adhesions. Retraction of synthetic tissues is observed in 20 to 30% of cases. Meshes in gynecology. In gynecology surgery, meshes made their first appearance in trans-abdominal sacrocolpopexy and slings. A detailed review of complications found in 32 articles studying slings and 22 studying sacrocolpopexy with approximately 10 types of meshes shows that intolerance of slings has oscillated between 1% with Prolene and 31% with Gore-Tex; for abdominal sacrocolpopexy the rate was between 1.7% with Prolene and 20% with Teflon. Rejection phenomena appear during the first year and are proportional to the surface area of the synthetic tissue and the proximity of the vaginal scar. New materials have been proposed over the last ten years for prolapse surgery, notably for cystocele, which accounts for 70% of all repair procedures. Nearly fifteen studies have reported a level of intolerance reaching 6%, the large majority of the meshes used being Prolene meshes. Our personal experience with 87 repair procedures has led us to the conclusion that Prolene is the most adapted mesh, allowing free tension between the bladder and the anterior vaginal wall. Continuous evaluation is needed to study these replacement materials which should in theory, improve the rate of recurrence, which is at present 20% with classic procedures not using a mesh.

  10. Laparoscopic Mesh Fixation Using Laser-Assisted Tissue Soldering in a Porcine Model

    PubMed Central

    Soltz, Barbara A.; Stadler, Istvan; Soltz, Robert

    2009-01-01

    Background and Objective: Animal studies using open surgical models indicate that collagen solder is capable of fixation of surgical meshes without interfering with tissue integration, increasing adhesions, or increasing inflammation intraperitoneally. This study describes development of instrumentation and techniques for laparoscopic herniorrhaphy using laser-assisted soldering technology. Study Design and Methods: Anesthetized 20 kg to 25 kg female Yorkshire pigs underwent laparoscopy with a 3-trocar technique. Parietex TET, Parietex TEC, and Prolene mesh segments (5 × 5 cm) were embedded in 55% collagen solder. Segments were inserted by using a specially designed introducer and affixed to the peritoneum by using prototype laser devices (1.45 µ, 4.5 W continuous wave, 5-mm spot, 55° C set temperature) and a custom laparoscopic handpiece (IPOM). Parietex PCO mesh was inserted and affixed using the Endo-hernia stapler (Control). Animals were recovered and underwent second-look laparoscopy at 6 weeks. Mesh sites were harvested after animals were euthanized. Results: The mesh-solder constructs were easily inserted and affixed in an IPOM approach. Prolene mesh tended to curl at its edges as the solder was melted. Postoperative healing was similar to that in Control segments in all cases. Discussion and Conclusion: Collagen-based tissue soldering permits normal wound healing and may mitigate or reduce the use of staples or other foreign bodies for laparoscopic mesh fixation, prevent tissue ischemia and possibly nerve entrapment, which result in severe postoperative pain and morbidity. Laser-assisted mesh fixation is a promising alternative for laparoscopic herniorrhaphy. Further development of this strategy is warranted. PMID:19793465

  11. Resistance to infection of five different materials in a rat body wall model.

    PubMed

    Medberry, Christopher J; Tottey, Stephen; Jiang, Hongbin; Johnson, Scott A; Badylak, Stephen F

    2012-03-01

    Infection occurs after approximately 1% of hernia repair procedures. The resistance to infection of the repair materials is therefore an important consideration. We evaluated the infection resistance of five different materials in a rat model of body wall repair, two of which, urinary bladder matrix (UBM-ECM) and Revive, were not previously evaluated in a controlled model of infection. An inoculum of 1 × 10(8) colony forming units of Staphylococcus aureus was delivered to the wound site following implantation of an autograft, UBM-ECM, Proceed, Prolene, or Revive. Infection was monitored by white blood cell counts, body temperature, bacterial culture, and histomorphologic analysis of the implant site. Infection was shown in all groups through increased white blood cell count and body temperature. Animals with UBM-ECM returned to pre-surgery body temperature before all other groups. Substantial bacterial clearance was found in the autograft, UBM-ECM, and Prolene. Histomorphologic analysis showed evidence for persistent bacterial infection in Prolene, Proceed, and Revive 28 d after implantation, whereas the autograft and UBM-ECM appeared free of infection. The autograft showed a pyogranulomatous inflammatory reaction at 28 d while UBM-ECM was similar to uninfected controls. Superior infection resistance was shown by UBM-ECM compared with the other materials, which were substantially equivalent. Histomorphologic analysis clearly showed an increased ability to resist persistent bacterial infection for UBM-ECM. Our results suggest UBM-ECM may be useful as a repair material in areas of high risk for infection. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. External tracheal stabilization technique for acquired tracheomalacia using a tailored silicone tube.

    PubMed

    Cho, Jong Ho; Kim, HoJoong; Kim, Jhingook

    2012-10-01

    Here, we describe an external tracheal stabilization technique used in a patient with tracheomalacia. A 56-year-old man presented with tracheomalacia due to prolonged mechanical ventilation. The malacic tracheal segment was approximately 2 cm in length. The malacic segment was covered with a silicone tube sutured in place using Prolene sutures (Ethicon, Somerville, NJ). Several anchoring sutures were placed between the tracheal mucosa and the silicone tube without violating the mucosal continuity. The patient was discharged on postoperative day 5 without complication. This method of external tracheal stabilization is a less invasive alternative for the management of this particular patient. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. High Throughput Assay for Bacterial Adhesion on Acellular Dermal Matrices and Synthetic Surgical Materials

    PubMed Central

    Nyame, Theodore T.; Lemon, Katherine P.; Kolter, Roberto; Liao, Eric C.

    2013-01-01

    Background There has been increasing use of various synthetic and biologically derived materials in surgery. Biologic surgical materials are used in many plastic surgery procedures, ranging from breast reconstruction to hernia repairs. In particular, acellular dermal matrix (ADM) material has gained popularity in these applications. There is a paucity of data on how ADM compares to other surgical materials as a substrate for bacterial adhesion, the first step in formation biofilm, which occurs in prosthetic wound infections. We have designed a high throughput assay to evaluate Staphylococcus aureus adherence on various synthetic and biologically derived materials. Methods Clinical isolates of Staphylococcus aureus (strains SC-1 and UAMS-1) were cultured with different materials and bacterial adherence was measured using a resazurin cell vitality reporter microtiter assay. Four materials that are commonly utilized in reconstructive procedures were evaluated: prolene mesh, vicryl mesh, and two different ADM preparations (AlloDerm®, FlexHD®). We were able to develop a high throughput and reliable assay for quantifying bacterial adhesion on synthetic and biologically derived materials. Results The resazurin vitality assay can be reliably used to quantify bacterial adherence to acellular dermal matrix material, as well as synthetic material. S. aureus strains SC-1 and UAMS-1 both adhered better to ADM materials (AlloDerm® vs. FlexHD®) than to the synthetic material prolene. S. aureus also adhered better to vicryl than to prolene. Strain UAMS-1 adhered better to vicryl and ADM materials than did strain SC-1. Conclusion Our results suggest that S. aureus adheres more readily to ADM material than to synthetic material. We have developed an assay to rapidly test bacterial formation on surgical materials, using two S. aureus bacterial strains. This provides a standard method to evaluate existing and new materials with regard to bacterial adherence and potential propensity for infection. This assay is particularly important in the clinical context of the severe sequelae of post-operative infection. PMID:22030489

  14. Delayed Tension Pneumothorax - Identification and Treatment in Traumatic Bronchial Injury: An Interesting Presentation.

    PubMed

    Gupta, Amit; Rattan, Amulya; Kumar, Sunil; Rathi, Vinita

    2017-09-01

    A 13-year-old girl, who did not receive any treatment for few hours following Road Traffic Injury (RTI), reported to the Casualty Department and found to have patent airway with clinically normal C spine, air-hunger (RR 42/minute), trachea deviated to left, distended neck veins and absent breath sounds on the right side. The chest X-ray she carried, done immediately after the injury, showed right sided tension pneumothorax. She was put on oxygen at 11 L/minute and an Intercostal chest tube drainage (ICD) was inserted on right side. Her oxygen saturation (40%) failed to improve. ICD bag showed continuous bubbling and air entry remained absent on the right side. An urgent right thoracotomy was done which revealed right main bronchus tear; the tear was repaired using interrupted Prolene ® sutures. Patient recovered well and was discharged 10 days later in a stable condition.

  15. Evaluation of four suture materials for surgical incision closure in Siberian sturgeon

    USGS Publications Warehouse

    Boone, S. Shaun; Hernandez, Sonia M.; Camus, Alvin C.; Peterson, Douglas C.; Jennings, Cecil A.; Shelton, James L.; Divers, Stephen J.

    2015-01-01

    The visual and microscopic tissue reactions to the absorbable monofilament Monocryl, absorbable monofilament triclosan-coated Monocryl-Plus, absorbable multifilament Vicryl, and nonabsorbable monofilament Prolene were evaluated for their use of surgical closure in Siberian Sturgeon Acipenser baerii. Postoperative assessments were conducted at 1, 2, 8, 12, and 26 and 55 weeks to visually evaluate the surgical incision for suture retention, incision healing, erythema, and swelling. Incisions were also assessed microscopically at 1, 2, and 8 weeks for necrosis, inflammation, hemorrhage, and fibroplasia. The results indicated that incisions closed with either Vicryl or Prolene suture materials were more likely to exhibit more erythema or incomplete healing compared with those closed with Monocryl or Monocryl-Plus. The surgical implantation of a transmitter in the coelomic cavity did not significantly affect the response variables among the four suture materials. Monocryl or Monocryl-Plus were equally effective and superior to other suture materials used for closing surgical incisions in Siberian Sturgeon or closely related species of sturgeon. Furthermore, Monocryl or Monocryl-Plus may decrease the risk of transmitter expulsion through the incision, as surgical wounds appear to heal faster and exhibit less erythema compared with those closed with Vicryl.

  16. A new improved technique for placement of a pursestring suture on the edge of the distal part of the rectal stump using a skin stapler for low anterior resection.

    PubMed

    Kumashiro, R; Sano, C; Ugaeri, H; Madokoro, S; Maekawa, T; Kumamoto, M; Hideshima, T; Inutsuka, S

    1994-04-01

    Instead of a linear stapler or manual pursestring suture onto the lower part of the rectum, we placed a No. 2-0 Prolene suture on the edge of the rectal stump, using 12 to 16 clips and a disposable skin stapler. This technique is satisfactory for very low anterior resection.

  17. Duct-to-duct biliary reconstruction after radical resection of Bismuth IIIa hilar cholangiocarcinoma.

    PubMed

    Wu, Wen-Guang; Gu, Jun; Dong, Ping; Lu, Jian-Hua; Li, Mao-Lan; Wu, Xiang-Song; Yang, Jia-Hua; Zhang, Lin; Ding, Qi-Chen; Weng, Hao; Ding, Qian; Liu, Ying-Bin

    2013-04-21

    At present, radical resection remains the only effective treatment for patients with hilar cholangiocarcinoma. The surgical approach for R0 resection of hilar cholangiocarcinoma is complex and diverse, but for the biliary reconstruction after resection, almost all surgeons use Roux-en-Y hepaticojejunostomy. A viable alternative to Roux-en-Y reconstruction after radical resection of hilar cholangiocarcinoma has not yet been proposed. We report a case of performing duct-to-duct biliary reconstruction after radical resection of Bismuth IIIa hilar cholangiocarcinoma. End-to-end anastomosis between the left hepatic duct and the distal common bile duct was used for the biliary reconstruction, and a single-layer continuous suture was performed along the bile duct using 5-0 prolene. The patient was discharged favorably without biliary fistula 2 wk later. Evidence for tumor recurrence was not found after an 18 mo follow-up. Performing bile duct end-to-end anastomosis in hilar cholangiocarcinoma can simplify the complex digestive tract reconstruction process.

  18. Gluteo-vaginal sinus formation complicating posterior intravaginal slingplasty followed by successful IVS removal. A case report and review of the literature.

    PubMed

    Mikos, Themistoklis; Tsalikis, Tryfon; Papanikolaou, Alexios; Pournaropoulos, Fotios; Bontis, John N

    2008-03-01

    Posterior intravaginal slingplasty (IVS) is a technique used for the treatment of apical prolapse. Type III meshes have been mostly used with this technique. In this article, a case of bilateral gluteo-vaginal sinus tract formation that complicated a posterior vaginal slingplasty with a type III mesh is presented. At 3 months follow-up, the patient complained for bulking through the vagina, continuous offensive vaginal discharge, and constant pain at the buttocks. She had prolapse recurrence, and there was defective healing at the gluteal entry points of the posterior IVS. Ten months after the initial surgery, she underwent a laparotomic subtotal hysterectomy and sacrocervicopexy with prolene type I mesh. At the same time, the posterior mesh was removed allowing the surgeon to discover communication of the canal of the mesh extending from gluteal incisions to the vagina epithelium. The sinus tract was managed surgically with excision of the surrounding tissues. There was no recurrence or other complications at 2 months follow-up.

  19. Ventral incisional hernia recurrence.

    PubMed

    Clark, J L

    2001-07-01

    During the period October 1993 to December 1996, 31 patients were operated on by the author for primary or recurrent ventral incisional hernia (VIH). Three patients were excluded from analysis because their records were unavailable for review. The median age of the 28 remaining patients at their initial procedure was 57.5 years (range, 37-78 years). The repair was performed with interrupted O-Ethibond sutures in all but 3 cases where Prolene suture was used secondary to noniatrogenic contamination or recurrent hernia. There were no unplanned enterotomies in the entire series and prophylactic intravenous antibiotics were used in all cases. The only significant complications were skin hyperemia after five repairs in 3 patients who were treated empirically with intravenous antibiotics, and 1 patient who had an antibiotic-associated rash. There were no 30-day mortalities. Prolene mesh was used exclusively in all repairs performed with mesh. Seven of these repairs (25%) were for recurrent VIH. Three of these seven patients had previous mesh repairs. Six of these seven patients who presented with recurrent VIH had a mesh repair and four developed a recurrence. Five of seven were active smokers, with one having severe obstructive lung disease. Four of seven related significant occupational lifting. Of the 21 patients having initial repair of VIH, mesh was used in 8 (38%). After a median follow-up of 13 months, there were 2 recurrent hernias (25%). The remaining 13 patients had primary closure of their hernias. After median follow-up of 25 months, there were 5 recurrences (38%). A total of 34 VIH repairs were performed on these 28 patients, of which 13 were for recurrent hernias. Five of thirteen (38%) of the mesh repairs for recurrent VIH failed. The median body mass index (BMI) for the 13 patients having primary repair was 26.4, and that for all 21 cases having mesh repair was 28.8. Patients with recurrent VIH frequently recur despite use of mesh, avoidance of contamination, and consistent technique. No difference in BMI was apparent in those who recurred. Continued smoking and occupational lifting may be important risk factors for recurrent VIH. Copyright 2001 Academic Press.

  20. Mechanical Loading for Peripheral Nerve Stabilization and Regeneration

    DTIC Science & Technology

    2013-04-01

    apple delivered within a New Skin liquid bandage will also be applied topically, as a deterrent. This constituted a minor amendment within our IACUC...Vicryl suture and the incision to the skin with 3-0 Prolene monofilament suture. The rat was kept for up to 3 weeks with full access to food and...Spagnoli, D., Gaini, S.M., Tanzi, M.C., Bresolin, N., Gri- moldi, N., and Torrente, Y. Skin -derived stem cells trans- planted into resorbable guides

  1. Novel laser tissue-soldering technique for dural reconstruction.

    PubMed

    Gil, Ziv; Shaham, Amit; Vasilyev, Tamar; Brosh, Tamar; Forer, Boaz; Katzir, Abraham; Fliss, Dan M

    2005-07-01

    The goal of this study was to use a modified version of the CO2 laser-soldering system to develop a simple and reliable technique for the repair of dural defects after excision of brain tumors. The authors used a CO2 fiber optic laser system that they had developed for heating, monitoring, and controlling tissue temperature in situ and in real time, thereby reducing damage to the brain parenchyma. They adapted the system for dural closure by using free fascial grafts in a porcine model. Measures for estimation of reconstruction quality included visual assessment under magnification and direct measurements of adhesive strength and cerebrospinal fluid leak (CSF) pressure. Reliable soldering was achieved in 54 of 57 experiments, providing a 95% success rate. The average peak adhesive strength was 82 +/- 3 mN/cm2. The measured leak pressure of the fascia-dura mater bond was 66 +/- 5 mm Hg. Conventional suturing performed using Prolene stitches resulted in immediate CSF leakage from areas between the stitches and from the area of the needle hole itself. Fascia-dura mater soldering using the CO2 laser is feasible and may support CSF pressure up to six times higher than normal intracranial pressure. Findings of this study may provide a basis for the development of new tools for dural reconstruction.

  2. Retrospective, Demographic, and Clinical Investigation of the Causes of Postoperative Infection in Patients With Lumbar Spinal Stenosis Who Underwent Posterior Stabilization.

    PubMed

    Yaldiz, Can; Yaldiz, Mahizer; Ceylan, Nehir; Kacira, Ozlem Kitiki; Ceylan, Davut; Kacira, Tibet; Kizilcay, Gokhan; Tanriverdi, Taner

    2015-07-01

    Owing to the increasing population of elderly patients, a large number of patients with degenerative spondylosis are currently being surgically treated. Although basic measures for decreasing postoperative surgical infections (PSIs) are considered, it still remains among the leading causes of morbidity and mortality. The aim of this retrospective analysis is to present possible causes leading to PSI in patients who underwent surgery for lumbar degenerative spondylosis and highlight how it can be avoided to decrease morbidity and mortality. The study included 540 patients who underwent posterior stabilization due to degenerative lumbar stenosis between January 2013 and January 2014. The data before and after surgery was retrieved from the hospital charts. Patients with degenerative lumbar stenosis who were operated upon in this study had >2 levels of laminectomy and facetectomy. For this reason, posterior stabilization was performed for all the patients included in this study. Determining the causes of postoperative infection (PI) following spinal surgeries performed with instrumentation is a struggle. Seventeen different parameters that may be related to PI were evaluated in this study. The presence of systemic diseases, unknown glove perforations, and perioperative blood transfusions were among the parameters that increased the prevalence of PI. Alternatively, prolene sutures, double-layered gloves, and the use of rifampicin Sv (RIS) decreased the incidence of PI. Although the presence of systemic diseases, unnoticed glove perforations, and perioperative blood transfusions increased PIs, prolene suture material, double-layered gloves, and the use of RIS decreased PIs.

  3. Plastic efficiency of different implants used for repair of soft and bone tissue defects.

    PubMed

    Iriyanov, Yu M; Chernov, V F; Radchenko, S A; Chernov, A V

    2013-08-01

    The results of clinical and experimental morphological studies of regenerates forming after replacement of large defects of the abdominal wall and tibia with implants from different materials (polytetrafluoroethylene, reperene, prolene, titanium, and titanium nickelide) are analyzed. Study of the regenerate histology and fibroarchitectonics has shown good prospects of mesh constructions from titanium nickelide for effective surgical repair of these defects. The use of this implant seems to be theoretically well-based and promising, particularly under conditions of suppurative infection and low individual reparative regenerative potential.

  4. Foreign body giant cells selectively covering haptics of intraocular lens implants: indicators of poor toleration?

    PubMed

    Wolter, J R

    1983-10-01

    A Sputnik lens implant removed after five years because of bullous keratopathy exhibits a dense covering of its Supramid anterior staves with large foreign body giant cells, while its Prolene loops and Polymethylmethacrylate optics have attracted only few of these cell units. The glass-membrane-like component of the reactive membrane also shows significant differences on the different parts of this implant. The use of observation of the components of reactive membranes on lens implants as indicators of toleration in the eye is suggested.

  5. Retrospective, Demographic, and Clinical Investigation of the Causes of Postoperative Infection in Patients With Lumbar Spinal Stenosis Who Underwent Posterior Stabilization

    PubMed Central

    Yaldiz, Can; Yaldiz, Mahizer; Ceylan, Nehir; Kacira, Ozlem Kitiki; Ceylan, Davut; Kacira, Tibet; Kizilcay, Gokhan; Tanriverdi, Taner

    2015-01-01

    Abstract Owing to the increasing population of elderly patients, a large number of patients with degenerative spondylosis are currently being surgically treated. Although basic measures for decreasing postoperative surgical infections (PSIs) are considered, it still remains among the leading causes of morbidity and mortality. The aim of this retrospective analysis is to present possible causes leading to PSI in patients who underwent surgery for lumbar degenerative spondylosis and highlight how it can be avoided to decrease morbidity and mortality. The study included 540 patients who underwent posterior stabilization due to degenerative lumbar stenosis between January 2013 and January 2014. The data before and after surgery was retrieved from the hospital charts. Patients with degenerative lumbar stenosis who were operated upon in this study had >2 levels of laminectomy and facetectomy. For this reason, posterior stabilization was performed for all the patients included in this study. Determining the causes of postoperative infection (PI) following spinal surgeries performed with instrumentation is a struggle. Seventeen different parameters that may be related to PI were evaluated in this study. The presence of systemic diseases, unknown glove perforations, and perioperative blood transfusions were among the parameters that increased the prevalence of PI. Alternatively, prolene sutures, double-layered gloves, and the use of rifampicin Sv (RIS) decreased the incidence of PI. Although the presence of systemic diseases, unnoticed glove perforations, and perioperative blood transfusions increased PIs, prolene suture material, double-layered gloves, and the use of RIS decreased PIs. PMID:26200620

  6. External aortic wrap for repair of type 1 endoleak☆

    PubMed Central

    Dean, Anastasia; Yap, Swee Leong; Bhamidipaty, Venu; Pond, Franklin

    2014-01-01

    INTRODUCTION Type 1 endoleak is a rare complication after endovascular abdominal aortic aneurysm repair (EVAR) with a reported frequency up to 2.88%. It is a major risk factor for aneurysmal enlargement and rupture. PRESENTATION OF CASE We present a case of a 68 year old gentleman who was found to have a proximal type 1 endoleak with loss of graft wall apposition on routine surveillance imaging post-EVAR. An initial attempt at endovascular repair was unsuccessful. Given the patient's multiple medical co-morbidities, which precluded the possibility of conventional graft explantation and open repair, we performed a novel surgical technique which did not require aortic cross-clamping. A double-layered Dacron wrap was secured around the infra-renal aorta with Prolene sutures, effectively hoisting the posterior bulge to allow wall to graft apposition and excluding the endoleak. Post-operative CT angiogram showed resolution of the endoleak and a stable sac size. DISCUSSION Several anatomical factors need to be considered when this technique is proposed including aortic neck angulation, position of lumbar arteries and peri-aortic venous anatomy. While an external wrap technique has been investigated sporadically for vascular aneurysms, to our knowledge there is only one similar case in the literature. CONCLUSION Provided certain anatomical features are present, an external aortic wrap is a useful and successful option to manage type 1 endoleak in high-risk patients who are unsuitable for aortic clamping. PMID:25217878

  7. Prolene hernia system compared with mesh plug technique: a prospective study of short- to mid-term outcomes in primary groin hernia repair.

    PubMed

    Huang, C S; Huang, C C; Lien, H H

    2005-05-01

    Two types of anterior tension-free hernioplasty, prolene hernia system (PHS) repair and mesh plug technique (MPT), were introduced to Taiwan in 2001. This study compared the short- to mid-term outcomes following primary groin hernia repair with PHS and MPT. From January 2001 to December 2003, 393 patients with 426 primary groin hernias were operated on by a single surgeon using MPT (n=192) and PHS (n=234). Baseline perioperative details and follow-up information were compared. Demographic characteristics of both groups were similar. The laterality, types of anesthesia, postoperative stay, postoperative wound pain scores, wound complications and days to return to activities of daily life were equally distributed between the two groups. However, the distribution of Gilbert types in the PHS group was shifted a little to the right compared with that of the MPT group. PHS repair had longer operative time (34+/-17 vs 25+/-9 minutes, p<0.01). No recurrence was noted in both groups during the follow-up from 5 to 41 months. Chronic non-disabling groin pains were noted in 2.8% (6/218) of patients in the PHS group and 8.9% (14/175) in the MPT group (p=0.01). Our results show that both PHS and MPT repairs can be performed with short operation time, minor wound pain and quick return to activities of daily life without short- to mid-term recurrences, but postoperatively the MPT group had higher incidence of chronic non-disabling groin pain. Although the MPT is less invasive, the additional protective patch in the preperitoneal space of the PHS may provide a further safeguard against recurrences, especially for those patients with attenuated inguinal floor. Long-term follow-up is needed.

  8. Randomized controlled trial comparing prolene hernia system and lichtenstein method for inguinal hernia repair.

    PubMed

    Sanjay, Pandanaboyana; Harris, Dean; Jones, Philippa; Woodward, Alan

    2006-07-01

    There are no data regarding the long-term outcomes of prolene hernia system (PHS) mesh in the published reports. The aim of the study was to compare the short-term and long-term outcomes of the PHS mesh with the Lichtenstein mesh technique. Sixty-four patients with inguinal hernia were randomized to undergo either a PHS or a Lichtenstein repair under local anaesthesia as a day case. Early outcome measures were duration of surgery, pain scores, analgesic requirements, time to return to work, driving and full activity. Long-term outcome measures were chronic groin pain and recurrence. Mean duration of surgery in the PHS group was 36 min (SD +/- 11) versus 34 min in the Lichtenstein group (SD +/- 8; P = 0.3). There was no significant difference in analgesic requirements (P = 0.65). Overall mean pain score was 3.5/10 versus 2.5/10 (P = 0.1). Mean time to return to work was 42 versus 30 days (P = 0.3), returning to driving was 20 versus 14 days (P = 0.2) and full activity was 21 versus 22 days (P = 0.8). Chronic groin pain developed in four patients in the PHS group (12.9%) and in five patients in the Lichtenstein group (15.1%; P > 0.05). One patient developed recurrent herniation in the PHS group. The median follow up was 4.2 years (range, 4-4.6 years). Patient satisfaction was very high with both the techniques. There is no significant difference in the early and long-term outcomes between PHS and Lichtenstein hernia repairs. The PHS technique involving preperitoneal dissection is well tolerated and easy to carry out under local anaesthesia.

  9. The telescoping suture--Part II: A novel method to improve the mechanical behavior of a new biomaterial: ostrich pericardium.

    PubMed

    García Páez, J M; Jorge Herrero, E; Rocha, A; Martín-Maestro, M; Castillo-Olivares, J L; Millán, I; Carrera Sanmartín, A; Cordón, A

    2002-10-01

    Ostrich pericardium, sutured using a telescoping or overlapping technique, was studied to determine its mechanical behavior. From each of 12 pericardial sacs, four contiguous strips were cut longitudinally, from root to apex, and another four contiguous strips were cut in transverse direction. One of the strips in each set of four was used as an unsutured control and the remaining three were sutured by overlapping 0.5 cm of the tissue and sewing with Gore-tex, Prolene or Pronova. These 96 samples were then subjected to tensile testing along their major axes until rupture. The tensile stresses recorded in the suture materials at the moment tears appeared in the pericardium ranged between 55.99 MPa and 70.23 MPa for Gore-tex in samples cut in the two directions. Shear stress became ostensible at 56 MPa, with clearly evident tears. However, microfracture of the collagen fibers must be produced at much lower stress levels. The comparison of the resistance in kilograms (machine-imposed), without taking into account the sections in which the load was applied, demonstrated only a slight loss of load when the telescoping suture was employed in ostrich pericardium samples. Ostrich pericardium may continue to be an alternative biological material for the construction of heart valve leaflets.

  10. Ptosis, extraocular motility disorder, and myopia as features of pompe disease.

    PubMed

    Slingerland, Niki W R; Polling, Jan Roelof; van Gelder, Catharina M; van der Ploeg, Ans T; Bleyen, Isabel

    2011-03-01

    The assets of this report are a thorough description of new clinical findings, namely the combination of ptosis, extraocular motility disorder and myopia, in consequence of prolonged survival in classic infantile-onset Pompe disease through enzyme therapy. Single case description. This manuscript describes a combination of ptosis, extraocular motility disorder and myopia in a 4.5-year-old patient with classic infantile-onset Pompe disease, who survived through enzyme therapy. This patient was treated with a bilateral frontalis suspension (modified Crawford technique) using prolene 3-0 sutures. The combination of ptosis, extraocular motility disorder and myopia, is a new clinical finding in children with classic infantile-onset Pompe disease.

  11. Biomechanical evaluation of potential damage to hernia repair materials due to fixation with helical titanium tacks.

    PubMed

    Lerdsirisopon, Sopon; Frisella, Margaret M; Matthews, Brent D; Deeken, Corey R

    2011-12-01

    This study aimed to determine whether the strength and extensibility of hernia repair materials are negatively influenced by the application of helical titanium tacks. This study evaluated 14 meshes including bare polypropylene, macroporous polytetrafluoroethylene, absorbable barrier, partially absorbable mesh, and expanded polytetrafluoroethylene materials. Each mesh provided 15 specimens, which were prepared in 7.5 × 7.5-cm squares. Of these, 5 "undamaged" specimens were subjected to ball-burst testing to determine their biomechanical properties before application of helical titanium tacks (ProTack). To 10 "damaged" specimens 7 tacks were applied 1 cm apart in a 3.5-cm-diameter circle using a tacking force of 25 to 28 N. The tacks were removed from five of the specimens before ball-burst testing and left intact in the remaining five specimens. The application of tacks had no effect on the tensile strength of Dualmesh, ProLite Ultra, Infinit, Ultrapro, C-QUR Lite (<6 in.), Prolene Soft, or Physiomesh, but the tensile strengths were reduced for Bard Mesh, C-QUR, ProLite, and C-QUR Lite (>6 in.). Most of the meshes did not exhibit significantly different tensile strengths between removal of tacks and tacks left intact. Exceptions included C-QUR, Prolene, Ultrapro, and Bard Soft Mesh, which were weaker with removal of tacks than with tacks left intact during the test. Damage due to the application of helical titanium tacks also caused increased strain at a stress of 16 N/cm for all the meshes except C-QUR Lite (>6 in.) and Physiomesh. Many of the meshes evaluated in this study exhibited damage in the form of reduced tensile strength and increased extensibility after the application of tacks compared with the corresponding "undamaged" meshes. Meshes with smaller interstices and larger filaments were influenced negatively by the application of helical titanium tacks, whereas mesh designs with larger interstices and smaller filaments tended to maintain their baseline mechanical properties.

  12. Esophagogastric fistula secondary to teflon pledget: a rare complication following laparoscopic fundoplication.

    PubMed

    Baladas, H G; Smith, G S; Richardson, M A; Dempsey, M B; Falk, G L

    2000-01-01

    Laparoscopic fundoplication has become the standard operation for gastroesophageal reflux disease. In our service, a laparoscopic fundoplication is performed as a 2-cm floppy 360 degrees wrap with division of the short gastric vessels and the fundoplication is sutured using a prolene 2/0 mattress suture (Ethicon, USA) and buttressed laterally with two teflon pledgets (PTFE 1.85 mm; low porosity, Bard, USA). We report a patient with post-operative dysphagia due to an esophagogastric fistula caused by erosion of a teflon pledget. This is the first such case in 734 laparoscopic fundoplications performed between January 1991 and December 1998. Reoperation was required, resulting in a prolonged convalescence. A review of current literature has not revealed any similar cases. Causes for this rare complication are postulated.

  13. A Ureteral Inguinoscrotal Hernia from a Pelvic Kidney

    PubMed Central

    Dikmen, Ayse V.; Guneri, Cagri; Yalcin, Serdar; Acikgoz, Onur; Ak, Esat; Cetiner, Sadettin

    2017-01-01

    A 74-year-old male patient with prostate cancer under remission was admitted with left inguinoscrotal swelling. He underwent scrotal ultrasound demonstrating a giant in-guinoscrotal hernia. Contrast-enhanced computerized tomography of the abdomen and pelvis demonstrated a left pelvic kidney associated with severe hydroureteronephrosis secondary to a ureteral inguinoscrotal hernia. Upon exploration with left inguinal incision, a paraperitoneal ureteral in-guinoscrotal hernia and a hypertrophic left spermatic cord were observed. The elongated and tortuous left ureter, being pulled down to the scrotum by the hernia, was released from the herniating tissues fullfilling left hemiscrotum. The ureter was tapered followed by ureteroureterostomy. The accompanying left spermatic cord was excessively elongated and curled, necessitating cordectomy. The hernia was repaired with prolene mesh after removal of herniating peritoneal tissue. This is a rare case of a paraperitoneal ureteral inguinoscrotal hernia of the left pelvic kidney. PMID:29463977

  14. 26 CFR 1.513-3 - Qualified convention and trade show activity.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 7 2014-04-01 2013-04-01 true Qualified convention and trade show activity. 1.513-3 Section 1.513-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Taxation of Business Income of Certain Exempt Organizations § 1.513-3 Qualified convention and...

  15. Investigation of the continuous flow of the sample solution on the performance of electromembrane extraction: Comparison with conventional procedure.

    PubMed

    Nojavan, Saeed; Sirani, Mahsa; Asadi, Sakine

    2017-10-01

    In this study, electromembrane extraction from a flowing sample solution, termed as continuous-flow electromembrane extraction, was developed and compared with conventional procedures for the determination of four basic drugs in real samples. Experimental parameters affecting the extraction efficiency were further studied and optimized. Under optimum conditions, linearity of continuous-flow procedure was within 8.0-500 ng/mL, while it was wider for conventional procedures (2.0-500 ng/mL). Moreover, repeatability (percentage relative standard deviation) was found to range between 5.6 and 10.4% (n = 3) for the continuous-flow procedure, with a better repeatability than that of conventional procedures (2.3-5.5% (n = 3)). Also, for the continuous-flow procedure, the estimated detection limit (signal-to-noise ratio = 3) was less than 2.4 ng/mL and extraction recoveries were within 8-10%, while the corresponding figures for conventional procedures were less than 0.6 ng/mL and 42-60%, respectively. Thus, the results showed that both continuous flow and conventional procedures were applicable for the extraction of model compounds. However, the conventional procedure was more convenient to use, and thus it was applied to determine sample drugs in real urine and wastewater samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Geology and oil and gas assessment of the Mancos-Menefee Composite Total Petroleum System: Chapter 4 in Total petroleum systems and geologic assessment of undiscovered oil and gas resources in the San Juan Basin Province, exclusive of Paleozoic rocks, New Mexico and Colorado

    USGS Publications Warehouse

    Ridgley, J.L.; Condon, S.M.; Hatch, J.R.

    2013-01-01

    Eight assessment units were defined in the Mancos-Menefee Composite TPS. Of the eight assessment units, four were assessed as conventional oil or gas accumulations and four as continuous-type accumulations. The conventional assessment units are Dakota-Greenhorn Conventional Oil and Gas Assessment Unit (AU), Gallup Sandstone Conventional Oil and Gas AU, Mancos Sandstones Conventional Oil AU, and the Mesaverde Updip Conventional Oil AU. Continuous-type assessments are Dakota-Greenhorn Continuous Gas AU, Mancos Sandstones Continuous Gas AU, Mesaverde Central-Basin Continuous Gas AU, and Menefee Coalbed Gas AU. The Mesaverde Updip Conventional AU was not quantitatively assessed for undiscovered oil and gas resources, because the producing oil fields were smaller than the 0.5 million barrel cutoff, and the potential of finding fields above this cutoff was considered to be low. Total oil resources that have the potential for additions to reserves in the next 30 years are estimated at a mean of 16.78 million barrels. Most of this resource will come from reservoirs in the Mancos Sandstones Oil AU. Gas resources that have the potential for additions to reserves in the next 30 years are estimated at a mean of 11.11 trillion cubic feet of gas (TCFG). Of this amount, 11.03 TCFG will come from continuous gas accumulations; the remainder will be gas associated with oil in conventional accumulations.Total natural gas liquids (NGL) that have the potential for additions to reserves in the next 30 years are estimated at a mean of 99.86 million barrels. Of this amount, 96.95 million barrels will come from the continuous gas assessment units, and 78.3 percent of this potential resource will come from the Mancos Sandstones Continuous Gas AU.

  17. 26 CFR 1.513-3 - Qualified convention and trade show activity.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 7 2010-04-01 2010-04-01 true Qualified convention and trade show activity. 1.513-3 Section 1.513-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Taxation of Business Income of Certain Exempt...

  18. Assessment of undiscovered conventional and continuous oil and gas resources of the Baltic Depression Province, 2014

    USGS Publications Warehouse

    Brownfield, Michael E.; Schenk, Christopher J.; Charpentier, Ronald R.; Klett, Timothy R.; Pitman, Janet K.; Tennyson, Marilyn E.; Gaswirth, Stephanie B.; Mercier, Tracey J.; Le, Phuong A.; Leathers, Heidi M.

    2015-01-01

    The U.S. Geological Survey estimated mean volumes of undiscovered, technically recoverable resources of 282 million barrels of conventional oil, 576 billion cubic feet of conventional gas, 1.3 billion barrels of continuous oil, and 4.6 trillion cubic feet of shale gas in the Baltic Depression Province.

  19. Endoscopic control of enterocutaneous fistula by dual intussuscepting stent technique.

    PubMed

    Melich, George; Pai, Ajit; Balachandran, Banujan; Marecik, Slawomir J; Prasad, Leela M; Park, John J

    2016-09-01

    Large high-output enterocutaneous fistulas pose great difficulties, especially in the setting of recent surgery and compromised skin integrity. This video demonstrates a new technique of endoscopic control of enterocutaneous fistula by using two covered overlapping stents. In brief, the two stents are each inserted endoscopically, one proximal, and the other distal to the fistula with 2 cm of each stent protruding cutaneously. Following this, the proximal stent is crimped and intussuscepted into the distal stent with an adequate overlap. A prolene suture is passed through the anterior wall of both stents to prevent migration. The two stents used were evolution esophageal stents-10 cm long, fully covered, double-flared with non-flared and flared diameters being 20 and 25 mm, respectively (product number EVO-FC-20-25-10-E, Cook Medical, Bloomington, IN, USA). The patient featured in this video developed a high-output enterocutaneous fistula proximal to a loop ileostomy, which was created following a small bowel leak after a curative surgery for bladder cancer. Using the technique featured in this video (schematic depicted in Fig. 1), the patient was nutritionally optimized with oral feeds from albumin of 0.9-3.4 g/dl within 2 months despite prior failure to achieve nutrition optimization and adequate skin protection with combination of oral and/or parenteral nutrition. Three months after stenting, following nutritional optimization and improvement of skin coverage, definitive procedure consisted of uncomplicated fistula resection with primary stapled side-to-side functional end-to-end anastomosis. The stents were not completely incorporated into the mucosa and were rather easily pulled through the residual fistula opening just prior to the surgery. Only minimal fibrosis was noted and less than 20 cm of involved small bowel needed to be resected. Had the fistula have closed completely, the options would have included (1) proceeding to bowel resection with removal of the stents regardless of closure, or (2) cutting the securing prolene stitch and observation. Considering the placement of the stents in mid-small bowel, their endoscopic retrieval would have been difficult unless they were to migrate into the colon. Although a prior attempt at managing an enterocutaneous fistula with a stent deployed through a colostomy site was previously reported [1], there is no published account of bridging an enterocutaneous fistula with overlapping endoscopic stents through the fistula itself. This video serves as a proof of concept for temporizing enterocutaneous fistulas with endoscopic stenting.

  20. Continuous Glucose Monitoring vs Conventional Therapy for Glycemic Control in Adults With Type 1 Diabetes Treated With Multiple Daily Insulin Injections: The GOLD Randomized Clinical Trial.

    PubMed

    Lind, Marcus; Polonsky, William; Hirsch, Irl B; Heise, Tim; Bolinder, Jan; Dahlqvist, Sofia; Schwarz, Erik; Ólafsdóttir, Arndís Finna; Frid, Anders; Wedel, Hans; Ahlén, Elsa; Nyström, Thomas; Hellman, Jarl

    2017-01-24

    The majority of individuals with type 1 diabetes do not meet recommended glycemic targets. To evaluate the effects of continuous glucose monitoring in adults with type 1 diabetes treated with multiple daily insulin injections. Open-label crossover randomized clinical trial conducted in 15 diabetes outpatient clinics in Sweden between February 24, 2014, and June 1, 2016 that included 161 individuals with type 1 diabetes and hemoglobin A1c (HbA1c) of at least 7.5% (58 mmol/mol) treated with multiple daily insulin injections. Participants were randomized to receive treatment using a continuous glucose monitoring system or conventional treatment for 26 weeks, separated by a washout period of 17 weeks. Difference in HbA1c between weeks 26 and 69 for the 2 treatments. Adverse events including severe hypoglycemia were also studied. Among 161 randomized participants, mean age was 43.7 years, 45.3% were women, and mean HbA1c was 8.6% (70 mmol/mol). A total of 142 participants had follow-up data in both treatment periods. Mean HbA1c was 7.92% (63 mmol/mol) during continuous glucose monitoring use and 8.35% (68 mmol/mol) during conventional treatment (mean difference, -0.43% [95% CI, -0.57% to -0.29%] or -4.7 [-6.3 to -3.1 mmol/mol]; P < .001). Of 19 secondary end points comprising psychosocial and various glycemic measures, 6 met the hierarchical testing criteria of statistical significance, favoring continuous glucose monitoring compared with conventional treatment. Five patients in the conventional treatment group and 1 patient in the continuous glucose monitoring group had severe hypoglycemia. During washout when patients used conventional therapy, 7 patients had severe hypoglycemia. Among patients with inadequately controlled type 1 diabetes treated with multiple daily insulin injections, the use of continuous glucose monitoring compared with conventional treatment for 26 weeks resulted in lower HbA1c. Further research is needed to assess clinical outcomes and longer-term adverse effects. clinicaltrials.gov Identifier: NCT02092051.

  1. Ear-lobe keloids: treatment by a protocol of surgical excision and immediate postoperative adjuvant radiotherapy.

    PubMed

    Ragoowansi, R; Cornes, P G; Glees, J P; Powell, B W; Moss, A L

    2001-09-01

    There is no universally agreed policy for treating keloid scars of the ear lobe following piercing. We treated 35 patients (34 women) for high-risk ear-lobe keloids; the average age was 24 years (range: 16-44 years). All had failed to respond to prior treatment with massage and silicone, and corticosteroid injection. The keloids were excised extralesionally and the defects were closed with interrupted prolene sutures. The operative scar was covered with topical 2% lignocaine-0.25% chlorhexidine sterile lubricant gel under a transparent adhesive dressing. Adjuvant postoperative radiotherapy of 10 Gy, applied as 100 kV photons (4 mm high-voltage therapy (HVT) Al), was given within 24 h of surgery. All keloid scars were controlled at 4 weeks' follow-up. At 1 year, three out of 34 cases followed up had relapsed (probability of control: 91.2%). At 5 years, a further four out of the remaining 31 patients had relapsed (cumulative probability of control at 5 years: 79.4%). There were no cases of serious toxicity. Copyright 2001 The British Association of Plastic Surgeons.

  2. Laser-assisted skin closure at 1.32 microns: the use of a software-driven medical laser system

    NASA Astrophysics Data System (ADS)

    Dew, Douglas K.; Hsu, Tung M.; Hsu, Long S.; Halpern, Steven J.; Michaels, Charles E.

    1991-06-01

    This study investigated the use of a computerized 1 .3 micron Nd:YAG laser to seal approximated wound edges in pig skin. The medical laser system used was the DLS Type 1 , 1 .32 micron Nd:YAG laser (Laser Surgery Software, Inc.). The purpose of this study was to evaluate the effectiveness of laser assisted skin closure using the DLS YAG laser in a large animal model. Effectiveness was judged on the basis of wound dehiscence, infection, unusual healing result and consistency of results. Comparative cosmetic result was also evaluated. In this study, the DLS YAG laser was used to close scalpel-induced, full-thickness wounds. The pig model was chosen for its many integumentary similarities to man. Controls included scalpel-induced wounds closed using suture, staple and some with norepair. After adequate anesthesia was achieved, the dorsum of Yucutan pigs (approximately 75- 100 pounds) each was clipped with animal hair clippers from the shoulder area to the hind legs. The area was then shaved with a razor blade, avoiding any inadvertent cuts or abrasions of the skin. The dorsum was divided into four rows of four parallel incisions made by a #15 scalpel blade. Full-thickness incisions, 9 cm long, were placed over the dorsum of the pigs and then closed either with one loosely approximating Prolene" suture (the "no repair' group), multiple interrupted 6-0 nylon sutures, staples or laser. The experimental tissue sealing group consisted of 1 69 laser assisted closures on 1 3 pigs. Sutured control wounds were closed with 6-0 nylon, full thickness, simple, interrupted sutures. Eight sutures were placed 1 cm apart along the 9 cm incision. Stapled control wounds were approximated using two evenly spaced 3-0 VicryP' sub-dermal sutures and the dermis closed using Proximate' skin staples. Eight staples were placed 1 cm apart along the 9 cm incision. The no-repair incisions were grossly approximated using a single 2-0 Prolene full thickness, simple, interrupted suture located at the center of the 9 cm incision. Experimental wounds were approximated using two evenly spaced subdermal 3.0 Vicryl' sutures and the dermis closed by laser sealing using the DLS YAG laser. Wounds were examined daily for the first seven days and followed for up to 20 months postoperatively. To facilitate wound edge approximation, surgical tape that is relatively transparent to 1.3 micron irradiation was used to hold the wound edges approximated while laser application occurred. Surgical tape was also applied to the "no-repair" suture and staple closures at the end of each procedure.

  3. Orthotopic neo- bladder in women.

    PubMed

    Schettini, Manlio

    2010-12-01

    Radical cystectomy is the most effective treatment madality for high grade urinary bladder carcinoma and orthotopic reconstruction is the better urinary diversion modality also in women. From 2002 to 2007 we performed 14 radical cystectomies followed by orthotopic reconstruction in women aged between 47 and 68 years (mean age 56) affected by urinary bladder carcinoma. Our reconstructive technique requires the preparation of two strips of the recti muscles fascia, the sectioning of the bladder neck and, when the uterus is present, hysteroannessiectomy and cystectomy en block leaving intact the lateral and inferior vaginal walls. The pelvic floor is stabilized by a colposacropexis with a prosthesis and placing an omental flap over the prosthesis. The orthotopic reconstruction is achieved via a neobladder according to the Padovana technique. The ureters are anastomized to the neobladder and splinted with single J stents. The pathological examination demonstrated in all patients the presence of a high grade carcinoma (G3): more specifically 4 patients had a full thickness intramural infiltration (T2), 2 patients had involvment of the perivescical fat (T3) ad 8 patients were in T1 stage. Lymphnodes were negative for tumour (NO). In 8 patients blood transfusions were necessary to treat post surgical anemia. No significant intra-, peri- or post operative complications were noted. The mean follow-up was 45 months: a patient died for diffuse metastatic disease after 11 months. The remaining patients are still alive and report normal lifestyle: 10 with normal micturition and 4 with urinary retention treated with intermittent self-catetherization. Two patients report nocturnal incontinence treated with hourly micturition and one pad. The five patients who had normal preoperative sexual intercourse resumed a normal sexual activity. The possibility to orthotopically recontruct the female urinary bladder has been established long time after the introduction of orthotopic neobladder in males, when became obvious that bladder reconstruction had to be done in conjunction with the reconstruction of the pelvic floor, in order to assure a satisfactory function at the new bladder. To avoid a posterior slippage of the vaginal stump we inserted the vaginal stump into a prolene tube which was then anchored posteriorly to the sacral periostium. We covered the prolene net with a flap of omentum pedicled down from the transverse colon and brought into the pelvis through the right colic space. This solid, stable and well protected support was able to accept the new bladder. We use the Padovana technique to facilitate the anastomosis of the bladder neck to the urethra. In the patients affected by urethral ipermotility we shaped a sub urethral sling using the recti muscles fascia pedicled by the pyramidal muscles. With this modality of reconstruction female pelvic anatomy is preserved as demonstrated by recovery of sexual activity.

  4. High-power and short-duration ablation for pulmonary vein isolation: Safety, efficacy, and long-term durability.

    PubMed

    Barkagan, Michael; Contreras-Valdes, Fernando M; Leshem, Eran; Buxton, Alfred E; Nakagawa, Hiroshi; Anter, Elad

    2018-05-30

    PV reconnection is often the result of catheter instability and tissue edema. High-power short-duration (HP-SD) ablation strategies have been shown to improve atrial linear continuity in acute pre-clinical models. This study compares the safety, efficacy and long-term durability of HP-SD ablation with conventional ablation. In 6 swine, 2 ablation lines were performed anterior and posterior to the crista terminalis, in the smooth and trabeculated right atrium, respectively; and the right superior PV was isolated. In 3 swine, ablation was performed using conventional parameters (THERMOCOOL-SMARTTOUCH ® SF; 30W/30 sec) and in 3 other swine using HP-SD parameters (QDOT-MICRO™, 90W/4 sec). After 30 days, linear integrity was examined by voltage mapping and pacing, and the heart and surrounding tissues were examined by histopathology. Acute line integrity was achieved with both ablation strategies; however, HP-SD ablation required 80% less RF time compared with conventional ablation (P≤0.01 for all lines). Chronic line integrity was higher with HP-SD ablation: all 3 posterior lines were continuous and transmural compared to only 1 line created by conventional ablation. In the trabeculated tissue, HP-SD ablation lesions were wider and of similar depth with 1 of 3 lines being continuous compared to 0 of 3 using conventional ablation. Chronic PVI without stenosis was evident in both groups. There were no steam-pops. Pleural markings were present in both strategies, but parenchymal lung injury was only evident with conventional ablation. HP-SD ablation strategy results in improved linear continuity, shorter ablation time, and a safety profile comparable to conventional ablation. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  5. 40 CFR 401.16 - Conventional pollutants.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Conventional pollutants. 401.16 Section 401.16 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GENERAL PROVISIONS § 401.16 Conventional pollutants. The following comprise the list of...

  6. 7 CFR 58.316 - Conventional churns.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Conventional churns. 58.316 Section 58.316 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....316 Conventional churns. Churns shall be constructed of aluminum, stainless steel or equally corrosion...

  7. 7 CFR 58.316 - Conventional churns.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Conventional churns. 58.316 Section 58.316 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards....316 Conventional churns. Churns shall be constructed of aluminum, stainless steel or equally corrosion...

  8. Segmented AC-coupled readout from continuous collection electrodes in semiconductor sensors

    DOEpatents

    Sadrozinski, Hartmut F. W.; Seiden, Abraham; Cartiglia, Nicolo

    2017-04-04

    Position sensitive radiation detection is provided using a continuous electrode in a semiconductor radiation detector, as opposed to the conventional use of a segmented electrode. Time constants relating to AC coupling between the continuous electrode and segmented contacts to the electrode are selected to provide position resolution from the resulting configurations. The resulting detectors advantageously have a more uniform electric field than conventional detectors having segmented electrodes, and are expected to have much lower cost of production and of integration with readout electronics.

  9. Continuous prophylaxis with recombinant factor IX Fc fusion protein and conventional recombinant factor IX products: comparisons of efficacy and weekly factor consumption.

    PubMed

    Iorio, Alfonso; Krishnan, Sangeeta; Myrén, Karl-Johan; Lethagen, Stefan; McCormick, Nora; Yermakov, Sander; Karner, Paul

    2017-04-01

    Continuous prophylaxis for patients with hemophilia B requires frequent injections that are burdensome and that may lead to suboptimal adherence and outcomes. Hence, therapies requiring less-frequent injections are needed. In the absence of head-to-head comparisons, this study compared the first extended-half-life-recombinant factor IX (rFIX) product-recombinant factor IX Fc fusion protein (rFIXFc)-with conventional rFIX products based on annualized bleed rates (ABRs) and factor consumption reported in studies of continuous prophylaxis. This study compared ABRs and weekly factor consumption rates in clinical studies of continuous prophylaxis treatment with rFIXFc and conventional rFIX products (identified by systematic literature review) in previously-treated adolescents and adults with moderate-to-severe hemophilia B. Meta-analysis was used to pool ABRs reported for conventional rFIX products for comparison. Comparisons of weekly factor consumption were based on the mean, reported or estimated from the mean dose per injection. Five conventional rFIX studies (injections 1 to >3 times/week) met the criteria for comparison with once-weekly rFIXFc reported by the B-LONG study. The pooled mean ABR for conventional rFIX was slightly higher than but comparable to rFIXFc (difference=0.71; p = 0.210). Weekly factor consumption was significantly lower with rFIXFc than in conventional rFIX studies (difference in means = 42.8-74.5 IU/kg/week [93-161%], p < 0.001). Comparisons of clinical study results suggest weekly injections with rFIXFc result in similar bleeding rates and significantly lower weekly factor consumption compared with more-frequently-injected conventional rFIX products. The real-world effectiveness of rFIXFc may be higher based on results from a model of the impact of simulated differences in adherence.

  10. 47 CFR 32.20 - Numbering convention.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 2 2011-10-01 2011-10-01 false Numbering convention. 32.20 Section 32.20 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES UNIFORM SYSTEM OF ACCOUNTS FOR TELECOMMUNICATIONS COMPANIES General Instructions § 32.20 Numbering convention. (a) The number “32...

  11. 47 CFR 32.20 - Numbering convention.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 2 2013-10-01 2013-10-01 false Numbering convention. 32.20 Section 32.20 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES UNIFORM SYSTEM OF ACCOUNTS FOR TELECOMMUNICATIONS COMPANIES General Instructions § 32.20 Numbering convention. (a) The number “32...

  12. 47 CFR 32.20 - Numbering convention.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 2 2014-10-01 2014-10-01 false Numbering convention. 32.20 Section 32.20 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES UNIFORM SYSTEM OF ACCOUNTS FOR TELECOMMUNICATIONS COMPANIES General Instructions § 32.20 Numbering convention. (a) The number “32...

  13. Long-term results of silicone expander for moderate and severe Brown syndrome (Brown syndrome "plus").

    PubMed

    Stager, D R; Parks, M M; Stager, D R; Pesheva, M

    1999-12-01

    The treatment of Brown syndrome has been undergoing an evolution toward more effective procedures with fewer operative interventions. Dr Kenneth Wright has introduced a procedure of superior oblique muscle tenotomy with a silicone expander to reduce the incidence of overcorrection. There was a retrospective study of 20 eyes of 19 consecutive patients with moderate or severe Brown syndrome (Brown syndrome "plus"). Follow-up ranged from 12 to 72 months. The expander, which varies 6 to 10 mm in length, was placed in all patients in the tenotomized superior oblique muscle tendon 5 mm nasal to the nasal border of the superior rectus muscle using 7-0 or 8-0 Prolene suture without violating the inner layer of the intermuscular septum. The intermuscular septum was closed over the silicone expander. One hundred percent of patients had resolution of the down shoot in adduction and some or full ability to elevate the eye in adduction. Twenty percent of patients required reoperation (12.5% using 5-8 mm expanders) for overcorrection. Restriction of downgaze was not seen postoperatively. Patients often show an undercorrection 1 to 6 months postoperatively and improve or occasionally overcorrect at 1 to 2 years postoperatively. One patient with a 10-mm expander extruded the implant. Placement of a 5- to 8-mm silicone expander in the tenotomized superior oblique muscle tendon is an effective means of correcting Brown syndrome with a low rate of reoperation. Initial undercorrection should not discourage the surgeon because improvement may continue for up to 3 years. The goal of treatment should be to convert a moderate or severe Brown syndrome (Brown syndrome plus) to a mild Brown syndrome ("true" Brown syndrome). This technique reduces the need for either simultaneous or subsequent inferior oblique muscle weakening and represents an advance in the treatment of Brown syndrome.

  14. 15 CFR 710.3 - Purposes of the Convention and CWCR.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS GENERAL INFORMATION AND OVERVIEW OF THE CHEMICAL WEAPONS CONVENTION REGULATIONS (CWCR) § 710.3 Purposes of..., produce, otherwise acquire, stockpile, or retain chemical weapons, or transfer, directly or indirectly...

  15. 15 CFR 710.3 - Purposes of the Convention and CWCR.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS GENERAL INFORMATION AND OVERVIEW OF THE CHEMICAL WEAPONS CONVENTION REGULATIONS (CWCR) § 710.3 Purposes of..., produce, otherwise acquire, stockpile, or retain chemical weapons, or transfer, directly or indirectly...

  16. 15 CFR 710.3 - Purposes of the Convention and CWCR.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS GENERAL INFORMATION AND OVERVIEW OF THE CHEMICAL WEAPONS CONVENTION REGULATIONS (CWCR) § 710.3 Purposes of..., produce, otherwise acquire, stockpile, or retain chemical weapons, or transfer, directly or indirectly...

  17. 15 CFR 710.3 - Purposes of the Convention and CWCR.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS GENERAL INFORMATION AND OVERVIEW OF THE CHEMICAL WEAPONS CONVENTION REGULATIONS (CWCR) § 710.3 Purposes of..., produce, otherwise acquire, stockpile, or retain chemical weapons, or transfer, directly or indirectly...

  18. Large spot transpupillary thermotherapy: a quicker laser for treatment of high risk prethreshold retinopathy of prematurity - a randomized study.

    PubMed

    Shah, Parag K; Narendran, V; Kalpana, N

    2011-01-01

    To compare structural and functional outcome and time efficiency between standard spot sized conventional pulsed mode diode laser and continuous mode large spot transpupillary thermotherapy (LS TTT) for treatment of high risk prethreshold retinopathy of prematurity (ROP). Ten eyes of five preterm babies having bilateral symmetrical high risk prethreshold ROP were included in this study. One eye of each baby was randomized to get either standard spot sized conventional pulsed mode diode laser or continuous mode LS TTT. There was no significant difference between structural or functional outcome in either group. The mean time taken for conventional diode laser was 20.07 minutes, while that for LS TTT was 12.3 minutes. LS TTT was 40% more time efficient than the conventional laser. It may be better suited for the very small fragile premature infants as it is quicker than the conventional laser.

  19. AECT Convention, Orlando, Florida 2008 Report

    ERIC Educational Resources Information Center

    Vega, Eddie

    2009-01-01

    This article presents several reports that highlight the events at the 2008 Association for Educational Communications and Technology (AECT) International Convention in Orlando, Florida. At the annual convention this year, the Multimedia Production Division goal was to continue to share information about the latest tools in multimedia production,…

  20. Use of clay to remediate cadmium contaminated soil under different water management regimes.

    PubMed

    Li, Jianrui; Xu, Yingming

    2017-07-01

    We examined in situ remediation of sepiolite on cadmium-polluted soils with diverse water regimes, and several variables including brown rice Cd, exchangeable Cd, pH, and available Fe/P. pH, available Fe/P in soils increased gradually during continuous flooding, which contributed to Cd absorption on colloids. In control group (untreated soils), compared to conventional irrigation, brown rice Cd in continuous flooding reduced by 37.9%, and that in wetting irrigation increased by 31.0% (p<0.05). In contrast to corresponding controls, brown rice Cd in sepiolite treated soils reduced by 44.4%, 34.5% and 36.8% under continuous flooding, conventional irrigation and wetting irrigation (p<0.05), and exchangeable Cd in amended soils reduced by 27.5-49.0%, 14.3-40.5%, and 24.9-32.8% under three water management regimes (p<0.05). Compared to corresponding controls, decreasing amplitudes of exchangeable Cd and brown rice Cd in sepiolite treated soils were higher in continuous flooding than in conventional irrigation and wetting irrigation. Continuous flooding management promoted soil Cd immobilization by sepiolite. Copyright © 2017. Published by Elsevier Inc.

  1. Treatment of severe cancer pain by low-dose continuous subcutaneous morphine.

    PubMed

    Drexel, H; Dzien, A; Spiegel, R W; Lang, A H; Breier, C; Abbrederis, K; Patsch, J R; Braunsteiner, H

    1989-02-01

    In a prospective and intraindividually controlled trial, we have compared the efficacy and safety of a continuous subcutaneous morphine infusion with conventional intermittent oral or subcutaneous morphine application. Twenty-eight in-patients with cancer pain received a short-term infusion lasting 2-42 days, and 8 out-patients underwent long-term infusion from 49 to 197 days during the terminal stage of their disease. Continuous subcutaneous morphine infusion significantly (P less than 0.001) improved both pain and quality of life when compared to conventional morphine application. With continuous infusion, 5-48 mg (median 19 mg) of morphine was required daily, significantly (P less than 0.001) less than the 10-90 mg (median 50 mg) necessary with conventional use. As a result of lower dosage, side effects under continuous infusion were infrequent and mild. Constipation occurred in 3 of the 36 patients and was always controlled by the addition of laxatives; no nausea, sedation or respiratory depression were observed. Signs of tolerance developed in 2 patients on long-term infusion, but the use of continuous subcutaneous methadone for 2 weeks reversed the tolerance. The study presented indicates that low-dose continuous subcutaneous morphine provides a valuable treatment modality for severe terminal cancer pain exhibiting a high degree of both efficacy and safety.

  2. 40 CFR 434.74 - Effluent limitations attainable by application of the best conventional pollutant control...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... application of the best conventional pollutant control technology (BCT). 434.74 Section 434.74 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS COAL MINING POINT... Effluent limitations attainable by application of the best conventional pollutant control technology (BCT...

  3. Intraparotid Neurofibroma of the Facial Nerve: A Case Report.

    PubMed

    Nofal, Ahmed-Abdel-Fattah; El-Anwar, Mohammad-Waheed

    2016-07-01

    Intraparotid neurofibromas of the facial nerve are extremely rare and mostly associated with neurofibromatosis type 1 (NF1). This is a case of a healthy 40-year-old man, which underwent surgery for a preoperatively diagnosed benign parotid gland lesion. After identification of the facial nerve main trunk, a single large mass (6 x 3 cm) incorporating the upper nerve division was observed. The nerve portion involved in the mass could not be dissected and was inevitably sacrificed with immediate neuroraphy of the upper division of the facial nerve with 6/0 prolene. The final histopathology revealed the presence of a neurofibroma. Complete left side facial nerve paralysis was observed immediately postoperatively but the function of the lower half was returned within 4 months and the upper half was returned after 1 year. Currently, after 3 years of follow up, there are no signs of recurrence and normal facial nerve function is observed. Neurofibroma should be considered as the diagnosis in a patient demonstrating a parotid mass. In cases where it is diagnosed intraoperatively, excision of part of the nerve with the mass will be inevitable though it can be successfully repaired by end to end anastomosis.

  4. Giant fibrosarcoma prostuberans of abodominal wall: management problems in resources-constrained country.

    PubMed

    Chukwuanukwu, T O G; Anyanwu, S N C

    2009-09-01

    Abdominal wall sarcomas represent less than 1% of adult malignancies. Dermatofibrosarcoma protuberans can grow to very large sizes and the recommended resection 2-3 cm from the macroscopic tumour margin can produce very large full thickness defects of the abdominal wall. Reconstruction of such defects can be quite challenging in resource constrained areas where patients present late with giant lesions. To highlight the presentation and management challenges faced by the surgical oncologist and reconstructive surgeon in a resource constrained country when faced with giant Dermatofibrosarcoma protuberans of the abdominal wall. Prospective study of patients with abdominal wall soft tissue sarcoma presenting to the authors. Cases of giant dermatofibrosarcoma protuberns who underwent surgery were analysed. Seven cases managed over an eight year period (January 2000 to December 2007). Age ranged from 27-70 yrs with slight female preponderance 1.5:1 F:M. Three presented with recurrent fungating masses. Only one could be reconstructed with prolene mesh. One recurrence was noted during the period under study. Poverty, ignorance and lack of necessary working tools are major challenges faced by the surgical oncologist and reconstructive surgeon in resource constrained areas and pose a major obstacle to the control of cancer in these areas.

  5. Orbital reconstruction in the dog, cat, and horse.

    PubMed

    Wallin-Håkansson, Nils; Berggren, Karin

    2017-07-01

    To describe an adaptable method for reconstruction of the orbit following partial orbitectomy. One horse, one cat, and four dogs. Following partial orbitectomy for removal of bone and soft tissue affected by pathologic processes, reconstruction was achieved. Cerclage wires were used to reconstitute the orbital rim and other salient facial contours involved in excisions. These wires were then covered with a prolene mesh, first inside the orbit and then outwards over the affected extraorbital areas. Thereafter, a collagen sheet was placed over the mesh. Finally, subcutis and skin were closed over the construct. All operated eyes remained visual with normal position, direction, and mobility. Eyelid function, tear production, and nasolacrimal function were preserved. Side effects were mild and temporary, but animals requiring a lateral-posterior surgical approach experienced concavity to the side of the head posterior to the orbital ligament region. One bone tumor out of three recurred. The reconstruction method presented offers excellent results tectonically, cosmetically, and functionally, even following extensive orbitectomy. By adapted application of three reconstruction steps using readily available materials, large defects may be surgically repaired. Once orbitectomy is mastered, reconstruction requires no additional specialized techniques or equipment. © 2016 American College of Veterinary Ophthalmologists.

  6. A Russian View on Landpower

    DTIC Science & Technology

    2015-04-01

    may also be obtained free of charge while supplies last by placing an order on the SSI website. SSI publications may be quoted or reprinted in part...areas of importance to a Western readership. Moscow continues to place primary importance on conventional military force, with the direct inten- tion of...2 almost a decade,2 as Moscow continues to place pri- mary importance on conventional military force, with the direct intention of growing

  7. Continuous microwave pasteurization of a vegetable smoothie improves its physical quality and hinders detrimental enzyme activity.

    PubMed

    Arjmandi, Mitra; Otón, Mariano; Artés, Francisco; Artés-Hernández, Francisco; Gómez, Perla A; Aguayo, Encarna

    2017-01-01

    The effect of a pasteurization treatment at 90 ± 2 ℃ for 35 s provided by continuous microwave under different doses (low power/long time and high power/short time) or conventional pasteurization on the quality of orange-colored smoothies and their changes throughout 45 days of storage at 5 ℃ was investigated. A better color retention of the microwave pasteurization- treated smoothie using high power/short time than in conventionally processed sample was evidenced by the stability of the hue angle. The continuous microwave heating increased the viscosity of the smoothie more than the conventional pasteurization in comparison with non-treated samples. Lower residual enzyme activities from peroxidase, pectin methylesterase and polygalacturonase were obtained under microwave heating, specifically due to the use of higher power/shorter time. For this kind of smoothie, polygalacturonase was the more thermo-resistant enzyme and could be used as an indicator of pasteurization efficiency. The use of a continuous semi-industrial microwave using higher power and shorter time, such as 1600 W/206 s and 3600 W/93 s, resulted in better quality smoothies and greater enzyme reduction than conventional thermal treatment. © The Author(s) 2016.

  8. Nanoporous films: From conventional to the conformal

    DOE PAGES

    Allendorf, Mark D.; Stavila, Vitalie

    2015-12-14

    Here, thin and continuous films of porous metal-organic frameworks can now be conformally deposited on various substrates using a vapor-phase synthesis approach that departs from conventional solution-based routes.

  9. 47 CFR 90.625 - Other criteria to be applied in assigning channels for use in conventional systems of communication.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... channels for use in conventional systems of communication. 90.625 Section 90.625 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES... applied in assigning channels for use in conventional systems of communication. (a) Where an applicant...

  10. 15 CFR Supplement No. 2 to Part 710 - Definitions of Production

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS GENERAL INFORMATION AND OVERVIEW OF THE CHEMICAL WEAPONS CONVENTION REGULATIONS (CWCR) Pt. 710, Supp. 2...

  11. 15 CFR Supplement No. 2 to Part 710 - Definitions of Production

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS GENERAL INFORMATION AND OVERVIEW OF THE CHEMICAL WEAPONS CONVENTION REGULATIONS (CWCR) Pt. 710, Supp. 2...

  12. 40 CFR 63.801 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... devices used to reduce emissions to the atmosphere. Conventional air spray means a spray coating method in... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission...

  13. 40 CFR 63.801 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... devices used to reduce emissions to the atmosphere. Conventional air spray means a spray coating method in... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission...

  14. 40 CFR 63.801 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... devices used to reduce emissions to the atmosphere. Conventional air spray means a spray coating method in... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission...

  15. 40 CFR 63.801 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... devices used to reduce emissions to the atmosphere. Conventional air spray means a spray coating method in... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission...

  16. EVALUATION OF DIOXIN EMISSIONS MONITORING SYSTEMS

    EPA Science Inventory

    Continuous samplers and real or semi-real-time continuous monitors for polychlorinated dibenzodioxins and furans provide significant advantages relative to conventional methods of extractive sampling. Continuous samplers collect long term samples over a time period of days to wee...

  17. Effects of Item Exposure for Conventional Examinations in a Continuous Testing Environment.

    ERIC Educational Resources Information Center

    Hertz, Norman R.; Chinn, Roberta N.

    This study explored the effect of item exposure on two conventional examinations administered as computer-based tests. A principal hypothesis was that item exposure would have little or no effect on average difficulty of the items over the course of an administrative cycle. This hypothesis was tested by exploring conventional item statistics and…

  18. The synthesis of cadmium sulfide nanoplatelets using a novel continuous flow sonochemical reactor

    DOE PAGES

    Palanisamy, Barath; Paul, Brian; Chang, Chih -hung

    2015-01-21

    A continuous flow sonochemical reactor was developed capable of producing metastable cadmium sulfide (CdS) nanoplatelets with thicknesses at or below 10 nm. The continuous flow sonochemical reactor included the passive in-line micromixing of reagents prior to sonochemical reaction. Synthesis results were compared with those from reactors involving batch conventional heating and batch ultrasound-induced heating. The continuous sonochemical synthesis was found to result in high aspect ratio hexagonal platelets of CdS possessing cubic crystal structures with thicknesses well below 10 nm. The unique shape and crystal structure of the nanoplatelets are suggestive of high localized temperatures within the sonochemical process. Asmore » a result, the particle size uniformity and product throughput are much higher for the continuous sonochemical process in comparison to the batch sonochemical process and conventional synthesis processes.« less

  19. Design of intelligent proximity detection zones to prevent striking and pinning fatalities around continuous mining machines.

    PubMed

    Bissert, P T; Carr, J L; DuCarme, J P; Smith, A K

    2016-01-01

    The continuous mining machine is a key piece of equipment used in underground coal mining operations. Over the past several decades these machines have been involved in a number of mine worker fatalities. Proximity detection systems have been developed to avert hazards associated with operating continuous mining machines. Incorporating intelligent design into proximity detection systems allows workers greater freedom to position themselves to see visual cues or avoid other hazards such as haulage equipment or unsupported roof or ribs. However, intelligent systems must be as safe as conventional proximity detection systems. An evaluation of the 39 fatal accidents for which the Mine Safety and Health Administration has published fatality investigation reports was conducted to determine whether the accident may have been prevented by conventional or intelligent proximity. Multiple zone configurations for the intelligent systems were studied to determine how system performance might be affected by the zone configuration. Researchers found that 32 of the 39 fatalities, or 82 percent, may have been prevented by both conventional and intelligent proximity systems. These results indicate that, by properly configuring the zones of an intelligent proximity detection system, equivalent protection to a conventional system is possible.

  20. Guiding principles of USGS methodology for assessment of undiscovered conventional oil and gas resources

    USGS Publications Warehouse

    Charpentier, R.R.; Klett, T.R.

    2005-01-01

    During the last 30 years, the methodology for assessment of undiscovered conventional oil and gas resources used by the Geological Survey has undergone considerable change. This evolution has been based on five major principles. First, the U.S. Geological Survey has responsibility for a wide range of U.S. and world assessments and requires a robust methodology suitable for immaturely explored as well as maturely explored areas. Second, the assessments should be based on as comprehensive a set of geological and exploration history data as possible. Third, the perils of methods that solely use statistical methods without geological analysis are recognized. Fourth, the methodology and course of the assessment should be documented as transparently as possible, within the limits imposed by the inevitable use of subjective judgement. Fifth, the multiple uses of the assessments require a continuing effort to provide the documentation in such ways as to increase utility to the many types of users. Undiscovered conventional oil and gas resources are those recoverable volumes in undiscovered, discrete, conventional structural or stratigraphic traps. The USGS 2000 methodology for these resources is based on a framework of assessing numbers and sizes of undiscovered oil and gas accumulations and the associated risks. The input is standardized on a form termed the Seventh Approximation Data Form for Conventional Assessment Units. Volumes of resource are then calculated using a Monte Carlo program named Emc2, but an alternative analytic (non-Monte Carlo) program named ASSESS also can be used. The resource assessment methodology continues to change. Accumulation-size distributions are being examined to determine how sensitive the results are to size-distribution assumptions. The resource assessment output is changing to provide better applicability for economic analysis. The separate methodology for assessing continuous (unconventional) resources also has been evolving. Further studies of the relationship between geologic models of conventional and continuous resources will likely impact the respective resource assessment methodologies. ?? 2005 International Association for Mathematical Geology.

  1. Comparative Effectiveness of New Mechanical Irrigant Agitating Devices for Debris Removal from the Canal and Isthmus of Mesial Roots of Mandibular Molars.

    PubMed

    Duque, Jussaro Alves; Duarte, Marco Antonio Hungaro; Canali, Lyz Cristina Furquim; Zancan, Rafaela Fernandes; Vivan, Rodrigo Ricci; Bernardes, Ricardo Affonso; Bramante, Clovis Monteiro

    2017-02-01

    The aim of this study was to compare the effectiveness of Easy Clean (Easy Dental Equipment, Belo Horizonte, MG, Brazil) in continuous and reciprocating motion, passive ultrasonic irrigation (PUI), Endoactivator systems (Dentsply Maillefer, Ballaigues, Switzerland), and conventional irrigation for debris removal from root canals and isthmus. Fifty mesial roots of mandibular molars were embedded in epoxy resin using a metal muffle; afterward, the blocks containing the roots were sectioned at 2, 4, and 6 mm from the apex. After instrumentation, the roots were divided into 5 groups (n = 10) for application of the final irrigation protocol using Easy Clean in continuous rotation, Easy Clean in reciprocating motion, PUI, Endoactivator, and conventional irrigation. Scanning electron microscopic images were taken after instrumentation and after the first, second, and third activation of irrigating solution to evaluate the area of remaining debris with image J software (National Institutes of Health, Bethesda, MD). The protocol of 3 irrigating solution activations for 20 seconds provided better cleaning of the canal and isthmus. On conclusion of all procedures, analysis of the canals showed a statistical difference only at 2 mm; the Easy Clean in continuous rotation was more efficient than conventional irrigation (P < .05). On conclusion of all steps, the largest difference was observed in the isthmus in which the Easy Clean in continuous rotation was more effective than conventional irrigation at the 3 levels analyzed and the Endoactivator at 4 mm (P < .05). The PUI promoted greater cleaning than conventional irrigation at 6 mm (P < .05). There was no statistical difference between Easy Clean in continuous rotation, Easy Clean in reciprocating motion, and PUI (P > .05). Irrigating solution activation methods provided better cleaning of the canal and isthmus, especially the Easy Clean used in continuous rotation. The protocol of 3 irrigating solution activations for 20 seconds favored better cleaning. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. A Longitudinal Analysis of Site of Death: The Effects of Continuous Enrollment in Medicare Advantage Versus Conventional Medicare.

    PubMed

    Chen, Elizabeth Edmiston; Miller, Edward Alan

    2017-09-01

    This study assessed the odds of dying in hospital associated with enrollment in Medicare Advantage (M-A) versus conventional Medicare Fee-for-Service (M-FFS). Data were derived from the 2008 and 2010 waves of the Health and Retirement Study ( n = 1,030). The sample consisted of elderly Medicare beneficiaries who died in 2008-2010 (34% died in hospital, and 66% died at home, in long-term senior care, a hospice facility, or other setting). Logistic regression estimated the odds of dying in hospital for those continuously enrolled in M-A from 2008 until death compared to those continuously enrolled in M-FFS and those switching between the two plans. Results indicate that decedents continuously enrolled in M-A had 43% lower odds of dying in hospital compared to those continuously enrolled in M-FFS. Financial incentives in M-A contracts may reduce the odds of dying in hospital.

  3. 49 CFR 572.181 - General description.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... reference in § 572.180, (5) Sign convention for signal outputs reference document SAE J1733 Information Report, titled “Sign Convention for Vehicle Crash Testing” dated December 1994, incorporated by reference...

  4. Mathematical modeling of continuous ethanol fermentation in a membrane bioreactor by pervaporation compared to conventional system: Genetic algorithm.

    PubMed

    Esfahanian, Mehri; Shokuhi Rad, Ali; Khoshhal, Saeed; Najafpour, Ghasem; Asghari, Behnam

    2016-07-01

    In this paper, genetic algorithm was used to investigate mathematical modeling of ethanol fermentation in a continuous conventional bioreactor (CCBR) and a continuous membrane bioreactor (CMBR) by ethanol permselective polydimethylsiloxane (PDMS) membrane. A lab scale CMBR with medium glucose concentration of 100gL(-1) and Saccharomyces cerevisiae microorganism was designed and fabricated. At dilution rate of 0.14h(-1), maximum specific cell growth rate and productivity of 0.27h(-1) and 6.49gL(-1)h(-1) were respectively found in CMBR. However, at very high dilution rate, the performance of CMBR was quite similar to conventional fermentation on account of insufficient incubation time. In both systems, genetic algorithm modeling of cell growth, ethanol production and glucose concentration were conducted based on Monod and Moser kinetic models during each retention time at unsteady condition. The results showed that Moser kinetic model was more satisfactory and desirable than Monod model. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Continuous Optimization on Constraint Manifolds

    NASA Technical Reports Server (NTRS)

    Dean, Edwin B.

    1988-01-01

    This paper demonstrates continuous optimization on the differentiable manifold formed by continuous constraint functions. The first order tensor geodesic differential equation is solved on the manifold in both numerical and closed analytic form for simple nonlinear programs. Advantages and disadvantages with respect to conventional optimization techniques are discussed.

  6. Assessment of undiscovered oil and gas resources in conventional and continuous petroleum systems in the Upper Cretaceous Eagle Ford Group, U.S. Gulf Coast region, 2011

    USGS Publications Warehouse

    Dubiel, Russell F.; Pitman, Janet K.; Pearson, Ofori N.; Pearson, Krystal; Kinney, Scott A.; Lewan, Michael D.; Burke, Lauri; Biewick, Laura; Charpentier, Ronald R.; Cook, Troy A.; Klett, Timothy R.; Pollastro, Richard M.; Schenk, Christopher J.

    2012-01-01

    Using a geology-based assessment methodology, the U.S. Geological Survey assessed means of (1) 141 million barrels of oil (MMBO), 502 billion cubic feet of natural gas (BCFG), and 16 million barrels of natural gas liquids (MMBNGL) in the conventional Eagle Ford Updip Sandstone Oil and Gas Assessment Unit (AU); (2) 853 MMBO, 1,707 BCFG, and 34 MMBNGL in the continuous Eagle Ford Shale Oil AU; and (3) 50,219 BCFG and 2,009 MMBNGL in the continuous Eagle Ford Shale Gas AU in onshore lands and State waters of the Gulf Coast.

  7. Closed anterior scoring for prominent-ear correction revisited.

    PubMed

    Thomas, S S; Fatah, F

    2001-10-01

    The closed-anterior-scoring technique has been used over the past 3 years to correct 56 prominent ears in 32 patients at the West Midlands Regional Plastic Surgery Unit at Wordsley Hospital. A review was carried out to assess the result of this surgical procedure. We briefly discuss the historical development of other surgical techniques for prominent-ear correction, and describe in detail the operative technique for this procedure, which includes closed scoring and suturing of the cartilage. We used this technique to treat 24 patients with bilateral prominent ears and eight patients with unilateral prominent ears. The series comprised 20 females and 12 males, 26 children and six adults. The age range was from 4 to 24 years old. There were two complications (an upper-pole recurrence and protrusion of a buried prolene suture). Patients were followed up for between 6 months and 3 years (mean: 1.5 years). This procedure is quick and technically easy to learn, with no anterior scars or posterior cartilage overlap. Minimal dissection is involved, leading to a low rate of complications. The learning curve is rapid; this paper represents the experience of a specialist trainee (SST) after he was taught the technique by the senior author. Copyright 2001 The British Association of Plastic Surgeons.

  8. Advanced Ultrasonic Diagnosis of Extremity Trauma: The Faster Exam

    NASA Technical Reports Server (NTRS)

    Dulchavsky, S. A.; Henry, S. E.; Moed, B. R.; Diebel, L. N.; Marshburn, T.; Hamilton, D. R.; Logan, J.; Kirkpatrick, A. W.; Williams, D. R.

    2002-01-01

    Ultrasound is of prO)len accuracy in abdominal and thoracic trauma and may be useful to diagnose extremity injury in situations where radiography is not available such as military and space applications. We prospectively evaluated the utility of extremity , ultrasound performed by trained, non-physician personnel in patients with extremity trauma, to simulate remote aerospace or military applications . Methods: Patients with extremity trauma were identified by history, physical examination, and radiographic studies. Ultrasound examination was performed bilaterally by nonphysician personnel with a portable ultrasound device using a 10-5 MHz linear probe, Images were video-recorded for later analysis against radiography by Fisher's exact test. The average time of examination was 4 minutes. Ultrasound accurately diagnosed extremity, injury in 94% of patients with no false positive exams; accuracy was greater in mid-shaft locations and least in the metacarpa/metatarsals. Soft tissue/tendon injury was readily visualized . Extremity ultrasound can be performed quickly and accurately by nonphysician personnel with excellent accuracy. Blinded verification of the utility of ultrasound in patients with extremity injury should be done to determine if Extremity and Respiratory evaluation should be added to the FAST examination (the FASTER exam) and verify the technique in remote locations such as military and aerospace applications.

  9. The 'Whip-Stow' procedure: an innovative modification to the whipple procedure in the management of premalignant and malignant pancreatic head disease.

    PubMed

    Jeyarajah, D Rohan; Khithani, Amit; Curtis, David; Galanopoulos, Christos A

    2010-01-01

    Pancreaticoduodenectomy (PD) is the standard of care in the treatment of premalignant and malignant diseases of the head of the pancreas. Variability exists in anastomosis with the pancreatic remnant. This work describes a safe and easy modification for the pancreatic anastomosis after PD. Ten patients underwent the "Whip-Stow" procedure for the management of the pancreatic remnant. PD combined with a Puestow (lateral pancreaticojejunostomy [LPJ]) was completed using a running single-layer, 4-0 Prolene obeying a duct-to-mucosa technique. LPJ and pancreaticogastrostomy (PG) historical leak rates are reported to be 13.9 and 15.8 per cent, respectively. Mortality, leak, and postoperative bleeding rates were 0 per cent in all patients. The Whip-Stow was completed without loops or microscope with a 4-0 single-layer suture decreasing the time and complexity of the anastomosis. Average time was 12 minutes as compared with the 50 minutes of a 5 or 6-0 interrupted, multilayered duct-mucosa anastomosis. Benefits included a long-segment LPJ. In this study, the Whip-Stow procedure has proven to be a safe and simple approach to pancreatic anastomosis in selected patients. This new technique provides the benefit of technical ease while obeying the age old principles of obtaining a wide duct to mucosa anastomosis.

  10. A continuous silicon-coating facility

    NASA Technical Reports Server (NTRS)

    Butter, C.; Heaps, J. D.

    1979-01-01

    Automatic continuous silicon-coating facility is used to process 100 by 10 cm graphite-coated ceramic substrates for silicon solar cells. Process reduces contamination associated with conventional dip-coating processes, improving material service life.

  11. 40 CFR 82.24 - Recordkeeping and reporting requirements for class II controlled substances.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... contrary to provisions of the Vienna Convention on Substances that Deplete the Ozone Layer, the Montreal... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Production and...

  12. 40 CFR 82.24 - Recordkeeping and reporting requirements for class II controlled substances.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... contrary to provisions of the Vienna Convention on Substances that Deplete the Ozone Layer, the Montreal... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PROTECTION OF STRATOSPHERIC OZONE Production and...

  13. 15 CFR Supplement No. 2 to Part 710 - Definitions of Production

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... reaction Produced by synthesis* Formation through chemical synthesis.Processing to extract and isolate... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS GENERAL INFORMATION AND OVERVIEW OF THE CHEMICAL WEAPONS CONVENTION REGULATIONS (CWCR) Pt. 710, Supp. 2...

  14. 7 CFR 1210.401 - District conventions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false District conventions. 1210.401 Section 1210.401 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... multi-State districts, no one State shall have nominees for more than three of the four district...

  15. 47 CFR 87.1 - Basis and purpose.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES AVIATION SERVICES... purpose for which this part is issued. (a) Basis. The rules for the aviation services in this part are... Regulations). (3) The Convention on International Civil Aviation—(ICAO Convention). (b) Purpose. This part...

  16. Purification of photon subtraction from continuous squeezed light by filtering

    NASA Astrophysics Data System (ADS)

    Yoshikawa, Jun-ichi; Asavanant, Warit; Furusawa, Akira

    2017-11-01

    Photon subtraction from squeezed states is a powerful scheme to create good approximation of so-called Schrödinger cat states. However, conventional continuous-wave-based methods actually involve some impurity in squeezing of localized wave packets, even in the ideal case of no optical losses. Here, we theoretically discuss this impurity by introducing mode match of squeezing. Furthermore, here we propose a method to remove this impurity by filtering the photon-subtraction field. Our method in principle enables creation of pure photon-subtracted squeezed states, which was not possible with conventional methods.

  17. 26 CFR 1.514(a)-1 - Unrelated debt-financed income and deductions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Taxation of Business Income of Certain Exempt..., applicable for taxable years beginning before January 1, 1972, and for special rules applicable to churches or conventions or associations of churches. (ii) Unrelated debt-financed income. The unrelated debt...

  18. 49 CFR 572.191 - General description.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY... the SID-IIsD Side Impact Crash Test Dummy, July 1, 2008,” and, (5) Sign convention for signal outputs reference document SAE J1733 Information Report, titled “Sign Convention for Vehicle Crash Testing,” dated...

  19. 15 CFR 716.5 - Notification, duration and frequency of inspections.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS... and purpose of the Convention posed by the quantities of chemicals produced, the characteristics of... Convention posed by the quantities of chemicals produced, the characteristics of the facility and the nature...

  20. Continuous Blood Pressure Monitoring in Daily Life

    NASA Astrophysics Data System (ADS)

    Lopez, Guillaume; Shuzo, Masaki; Ushida, Hiroyuki; Hidaka, Keita; Yanagimoto, Shintaro; Imai, Yasushi; Kosaka, Akio; Delaunay, Jean-Jacques; Yamada, Ichiro

    Continuous monitoring of blood pressure in daily life could improve early detection of cardiovascular disorders, as well as promoting healthcare. Conventional ambulatory blood pressure monitoring (ABPM) equipment can measure blood pressure at regular intervals for 24 hours, but is limited by long measuring time, low sampling rate, and constrained measuring posture. In this paper, we demonstrate a new method for continuous real-time measurement of blood pressure during daily activities. Our method is based on blood pressure estimation from pulse wave velocity (PWV) calculation, which formula we improved to take into account changes in the inner diameter of blood vessels. Blood pressure estimation results using our new method showed a greater precision of measured data during exercise, and a better accuracy than the conventional PWV method.

  1. A Non-Conventional Interdiction Strategy for the Global War on Terror

    DTIC Science & Technology

    2007-06-01

    thesis is to explore an alternative strategic focus for the Department of Defense to implement in the conduct of the Global War on Terrorism. Our...thesis is as follows: A non-conventional approach to strategic policy, led by an enhanced Foreign Internal Defense concept, and judicious execution of...been and continues to be limited by its conventional tactical successes, when what is required is strategic application of FID, UW, and limited

  2. Report of the Proceedings of the Forty-Sixth Meeting of the Convention of American Instructors of the Deaf; Indiana School for the Deaf, Indianapolis, Indiana. Convention Theme: "Educational Crossroads for Deaf Children". June 24-29, 1973.

    ERIC Educational Resources Information Center

    Davis, Ferne E., Ed.

    Presented are proceedings of the 46th (1973) meeting of the Convention of American Instructors of the Deaf. Included are numerous papers and discussions on auditory training, career development, continuing education, reading and language, counseling, curriculum, deaf-blind children, diagnostic assessment, early education, total communication,…

  3. Geology and sequence stratigraphy of undiscovered oil and gas resources in conventional and continuous petroleum systems in the Upper Cretaceous Eagle Ford Group and related strata, U.S. Gulf Coast Region

    USGS Publications Warehouse

    Dubiel, Russell F.; Pearson, Ofori N.; Pitman, Janet K.; Pearson, Krystal M.; Kinney, Scott A.

    2012-01-01

    The U.S. Geological Survey (USGS) recently assessed the technically recoverable undiscovered oil and gas onshore and in State waters of the Gulf Coast region of the United States. The USGS defined three assessment units (AUs) with potential undiscovered conventional and continuous oil and gas resources in Upper Cretaceous (Cenomanian to Turonian) strata of the Eagle Ford Group and correlative rocks. The assessment is based on geologic elements of a total petroleum system, including hydrocarbon source rocks (source rock maturation, hydrocarbon generation and migration), reservoir rocks (sequence stratigraphy and petrophysical properties), and traps (formation, timing, and seals). Conventional oil and gas undiscovered resources are in updip sandstone reservoirs in the Upper Cretaceous Tuscaloosa and Woodbine Formations (or Groups) in Louisiana and Texas, respectively, whereas continuous oil and continuous gas undiscovered resources reside in the middip and downdip Upper Cretaceous Eagle Ford Shale in Texas and the Tuscaloosa marine shale in Louisiana. Conventional resources in the Tuscaloosa and Woodbine are included in the Eagle Ford Updip Sandstone Oil and Gas AU, in an area where the Eagle Ford Shale and Tuscaloosa marine shale display vitrinite reflectance (Ro) values less than 0.6%. The continuous Eagle Ford Shale Oil AU lies generally south of the conventional AU, is primarily updip of the Lower Cretaceous shelf edge, and is defined by thermal maturity values within shales of the Eagle Ford and Tuscaloosa that range from 0.6 to 1.2% Ro. Similarly, the Eagle Ford Shale Gas AU is defined downdip of the shelf edge where source rocks have Ro values greater than 1.2%. For undiscovered oil and gas resources, the USGS assessed means of: 1) 141 million barrels of oil (MMBO), 502 billion cubic feet of natural gas (BCFG), and 4 million barrels of natural gas liquids (MMBNGL) in the Eagle Ford Updip Sandstone Oil and Gas AU; 2) 853 MMBO, 1707 BCFG, and 34 MMBNGL in the Eagle Ford Shale Oil AU; and 3) 50,219 BCFG and 2009 MMBNGL in the Eagle Ford Shale Gas AU.

  4. Incidence of Tardive Dyskinesia with Atypical and Conventional Antipsychotic Medications: Prospective Cohort Study

    PubMed Central

    Woods, Scott W.; Morgenstern, Hal; Saksa, John R.; Walsh, Barbara C.; Sullivan, Michelle C.; Money, Roy; Hawkins, Keith A.; Gueorguieva, Ralitza V.; Glazer, William M.

    2011-01-01

    Objective Most previous studies of the incidence of tardive dyskinesia with atypical compared to conventional antipsychotics have not had tardive dyskinesia as their primary focus. The current study aimed to compare the incidence of tardive dyskinesia with atypical vs. conventional antipsychotics using methods similar to those from a previous prospective cohort study at our site in the 1980s. Method 352 initially tardive dyskinesia-free psychiatric outpatients were examined for a new diagnosis of tardive dyskinesia every 6 months for up to 4 years at a community mental health center. At baseline, subjects were receiving conventional antipsychotics only (23%), atypicals only (64%), or both (14%). Only 26 subjects had never received conventional antipsychotics. Results Compared with subjects treated with conventional antipsychotics alone since the previous visit, the adjusted tardive dyskinesia incidence rate-ratio for subjects treated with atypical antipsychotics alone was 0.68 (95% confidence interval 0.29 to 1.64). The incidence and prevalence of tardive dyskinesia was similar to previous findings at this site in the 1980s. Conclusion The incidence of tardive dyskinesia with recent exposure to atypical antipsychotics alone was more similar to that for conventional antipsychotics than in most previous studies. Despite high penetration of atypical antipsychotics into clinical practice, the incidence and prevalence of tardive dyskinesia appeared relatively unchanged since the 1980s. Clinicians should continue to monitor for tardive dyskinesia, and researchers should continue to pursue efforts to treat or prevent it. PMID:20156410

  5. 40 CFR 141.174 - Filtration sampling requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....174 Section 141.174 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection... water system subject to the requirements of this subpart that provides conventional filtration treatment...

  6. 40 CFR 141.174 - Filtration sampling requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ....174 Section 141.174 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection... water system subject to the requirements of this subpart that provides conventional filtration treatment...

  7. 40 CFR 141.174 - Filtration sampling requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....174 Section 141.174 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Filtration and Disinfection... water system subject to the requirements of this subpart that provides conventional filtration treatment...

  8. 15 CFR 710.4 - Overview of scheduled chemicals and examples of affected industries.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS GENERAL INFORMATION AND OVERVIEW OF THE CHEMICAL WEAPONS CONVENTION... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Overview of scheduled chemicals and...

  9. REMOVAL OF CRYPTOSPORIDIUM AND GIARDIA THROUGH CONVENTIONAL WATER TREATMENT AND DIRECT FILTRATION

    EPA Science Inventory

    Pilot- and full-scale evaluations of Giardia and Cryptosporidium cyst removal through direction filtration and conventional water treatment were conducted by the Utah Department of Environmental Quality. Cysts were seeded continuously in a step dose at a 0.5 gpm pilot plant and i...

  10. 40 CFR 439.33 - Effluent limitations attainable by the application of the best conventional pollutant control...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Effluent limitations attainable by the application of the best conventional pollutant control technology (BCT). 439.33 Section 439.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PHARMACEUTICAL...

  11. 40 CFR 439.23 - Effluent limitations attainable by the application of the best conventional pollutant control...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Effluent limitations attainable by the application of the best conventional pollutant control technology (BCT). 439.23 Section 439.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PHARMACEUTICAL...

  12. 40 CFR 439.13 - Effluent limitations attainable by the application of the best conventional pollutant control...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Effluent limitations attainable by the application of the best conventional pollutant control technology (BCT). 439.13 Section 439.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PHARMACEUTICAL...

  13. 40 CFR 439.43 - Effluent limitations attainable by the application of the best conventional pollutant control...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Effluent limitations attainable by the application of the best conventional pollutant control technology (BCT). 439.43 Section 439.43 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PHARMACEUTICAL...

  14. Re-Picturing Photography: A Language in the Making

    ERIC Educational Resources Information Center

    Navab, Aphrodite Desiree

    2001-01-01

    For over one hundred and fifty years practitioners, critics, and historians have continuously challenged and added dimensions to the meaning and uses of photography. Yet there has been little challenge to its highly disturbing linguistic conventions. By uncritically accepting and using these conventions, those involved in the culture of…

  15. The American High School

    ERIC Educational Resources Information Center

    Ediger, Marlow

    2008-01-01

    Of all levels of schooling, the high school receives by far the most criticism. There are continuous innovations recommended in journal articles, textbooks, and speeches at state/national conventions on ways to improve the secondary level of schooling. At one teacher education convention, the speaker was criticizing the American high school and…

  16. Stratification of soil chemical and microbial properties under no-till management after lime amendment

    USDA-ARS?s Scientific Manuscript database

    Adoption of no-till (NT) technology in the dryland cropping region of the inland Pacific Northwest (iPNW) has dramatically reduced soil erosion compared to conventional tillage. Soils under continuous NT, however, often produce stratified soil acidification compared with conventional tillage due to ...

  17. 40 CFR 463.17 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... representing the degree of effluent reduction attainable by the application of the best conventional pollutant... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PLASTICS MOLDING AND FORMING POINT SOURCE CATEGORY Contact... effluent reduction attainable by the application of the best conventional pollutant control technology...

  18. Continuous noninvasive ventilation delivered by a novel total face mask: a case series report.

    PubMed

    Belchior, Inês; Gonçalves, Miguel R; Winck, João Carlos

    2012-03-01

    Noninvasive ventilation (NIV) has been widely used to decrease the complications associated with tracheal intubation in mechanically ventilated patients. However, nasal ulcerations may occur when conventional masks are used for continuous ventilation. A total face mask, which has no contact with the more sensitive areas of the face, is a possible option. We describe 3 patients with acute respiratory failure due to amyotrophic lateral sclerosis, who developed nasal bridge skin necrosis during continuous NIV, and one patient with post-extubation respiratory failure due to a high spinal cord injury, who had facial trauma with contraindication for conventional mask use. The total face mask was very well tolerated by all the patients, and permitted safe and efficient continuous NIV for several days until the acute respiratory failure episode resolved. None of the patients required endotracheal intubation during the acute episode.

  19. Two-Year Safety and Efficacy Experience in Patients with Methotrexate-Resistant Active Rheumatoid Arthritis Treated with Etanercept and Conventional Disease-Modifying Anti-rheumatic Drugs in the Latin American Region.

    PubMed

    Machado, Daniel A; Guzman, Renato; Xavier, Ricardo M; Simon, Jesus A; Mele, Linda; Shen, Qi; Pedersen, Ronald; Kotak, Sameer; Vlahos, Bonnie

    2016-01-01

    Although long-term data are available from biologic studies in North American/European populations with rheumatoid arthritis (RA), long-term findings in Latin American RA populations are limited. To examine long-term safety/efficacy of etanercept, methotrexate, and/or other disease-modifying anti-rheumatic drugs (DMARDs) in Latin American patients with moderate-to-severe active RA. In the first phase of this open-label study, patients were randomized to etanercept 50 mg weekly plus methotrexate or conventional DMARD (hydroxychloroquine or sulfasalazine) plus methotrexate for 24 weeks. At the start of the second phase (week 24), investigators selected a treatment regimen that included any combination/dosage of etanercept, methotrexate, hydroxychloroquine, or sulfasalazine based on previous treatment response, preference, and local product labeling, and was continued for the 104-week extension. In the extension, in the group previously randomized to etanercept-plus-methotrexate therapy, etanercept was continued in 259/260 patients; methotrexate continued in 260/260; and hydroxychloroquine and sulfasalazine added in 8/260 and 3/260, respectively. In the group previously randomized to conventional DMARD-plus-methotrexate therapy, conventional DMARD was discontinued in 86/126 and etanercept added in 105/126. Among etanercept-exposed patients (total exposure, 798.1 patient-year [PY]), rates of adverse events, serious adverse events, and serious infections per PY were 1.7, 0.07, and 0.02 events per PY. In both groups, after treatment modification was permitted, clinical response rates and improvements in clinical/patient-reported outcomes from baseline were sustained to week 128. After investigators were permitted to modify treatment, etanercept was part of the treatment regimen in 95% of patients. Continuation or addition of etanercept in the 2-year extension resulted in a consistently good risk:benefit profile. Open-Label Study Comparing Etanercept to Conventional Disease Modifying Antirheumatic Drug (DMARD) Therapy; ClinicalTrials.gov, number NCT00848354; https://clinicaltrials.gov/ct2/show/NCT00848354.

  20. Continuing Education in a Lifelong Learning Society: The Hong Kong Model

    ERIC Educational Resources Information Center

    Young, Enoch C. M.

    2008-01-01

    This paper examines the role and position of continuing education in the lifelong learning society of Hong Kong. The first section describes the basic components of Hong Kong's lifelong learning system, which is composed of two interconnected sub-systems--namely, conventional education and continuing education--integrated under a common…

  1. N-Consecutive-Phase Encoder

    NASA Technical Reports Server (NTRS)

    Divsalar, Dariush; Lee, Ho-Kyoung; Weber, Charles

    1995-01-01

    N-consecutive-phase encoder (NCPE) is conceptual encoder for generating alphabet of N consecutive full-response continuous-phase-modulation (CPM) signals. Enables use of binary preencoder of higher rate than used with simple continuous-phase encoder (CPE). NCPE makes possible to achieve power efficiencies and bandwidth efficiencies greater than conventional trellis coders with continuous-phase frequency-shift keying (CPFSK).

  2. U.S. Geological Survey 2013 assessment of undiscovered resources in the Bakken and Three Forks Formations of the U.S. Williston Basin Province

    USGS Publications Warehouse

    Gaswirth, Stephanie B.; Marra, Kristen R.

    2014-01-01

    The Upper Devonian Three Forks and Upper Devonian to Lower Mississippian Bakken Formations comprise a major United States continuous oil resource. Current exploitation of oil is from horizontal drilling and hydraulic fracturing of the Middle Member of the Bakken and upper Three Forks, with ongoing exploration of the lower Three Forks, and the Upper, Lower, and Pronghorn Members of the Bakken Formation. In 2008, the U.S. Geological Survey (USGS) estimated a mean of 3.65 billion bbl of undiscovered, technically recoverable oil resource within the Bakken Formation. The USGS recently reassessed the Bakken Formation, which included an assessment of the underlying Three Forks Formation. The Pronghorn Member of the Bakken Formation, where present, was included as part of the Three Forks assessment due to probable fluid communication between reservoirs. For the Bakken Formation, five continuous and one conventional assessment units (AUs) were defined. These AUs are modified from the 2008 AU boundaries to incorporate expanded geologic and production information. The Three Forks Formation was defined with one continuous and one conventional AU. Within the continuous AUs, optimal regions of hydrocarbon recovery, or “sweet spots,” were delineated and estimated ultimate recoveries were calculated for each continuous AU. Resulting undiscovered, technically recoverable resource estimates were 3.65 billion bbl for the five Bakken continuous oil AUs and 3.73 billion bbl for the Three Forks Continuous Oil AU, generating a total mean resource estimate of 7.38 billion bbl. The two conventional AUs are hypothetical and represent a negligible component of the total estimated resource (8 million barrels of oil).

  3. Bugs and gas: Agreements banning chemical and biological weapons

    NASA Astrophysics Data System (ADS)

    Mikulak, Robert P.

    2017-11-01

    The use of chemical or biological weapons, whether by a State or terrorists, continues to be a serious security concern. Both types of weapons are prohibited by multilateral treaties that have very broad membership, but both the Biological Weapons Convention and the Chemical Weapons Convention are facing major challenges. In particular, the continued use of chemical weapons in the Syrian civil war by government forces risks eroding the norm against the use of such weapons. This paper briefly explore the recent history of efforts to constrain chemical and biological weapons and outlines challenges for the future.

  4. 26 CFR 1.883-0T - Outline of major topics (temporary).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... TAX (CONTINUED) INCOME TAXES Foreign Corporations § 1.883-0T Outline of major topics (temporary). This... income from the international operation of ships or aircraft (temporary). (a) through (c)(3)(i) [Reserved...) Special rules with respect to income tax conventions. (i) Countries with only an income tax convention...

  5. 47 CFR 64.803 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) MISCELLANEOUS... Communications Services to Candidates for Federal Office § 64.803 Definitions. For the purposes of this subpart... means (1) a general, special, primary, or runoff election, (2) a convention or caucus of a political...

  6. Propulsion and Power Rapid Response Research and Development (R&D) Support. Task Order 0011: JP-8+100 Development History and Maintenance Benefits

    DTIC Science & Technology

    2010-06-01

    toxicological problems associated with conventional JP-8. Due to the decreased volatility of JP-8, diligent and continued use of personal protective... conventional aircraft engines. However, designers also realized that as fuel operating temperatures were increased, the formation of coke in fuel...beyond that which would typically be experienced by conventional JP-8 at 325 °F. Increasing the thermal stability margin by 100 °F would provide an

  7. Geology and oil and gas assessment of the Fruitland Total Petroleum System, San Juan Basin, New Mexico and Colorado: Chapter 6 in Geology and Oil and Gas Assessment of the Fruitland Total Petroleum System, San Juan Basin, New Mexico and Colorado

    USGS Publications Warehouse

    Ridgley, J.L.; Condon, S.M.; Hatch, J.R.

    2013-01-01

    Four assessment units (AU) were defined in the Fruitland TPS. Of the four AUs, one consists of conventional gas accumulations and the other three are continuous-type gas accumulations: Tertiary Conventional Gas AU, Pictured Cliffs Continuous Gas AU, Basin Fruitland Coalbed Gas (CBG) AU, and Fruitland Fairway CBG AU. No oil resources that have the potential for additions to reserves in the next 30 years were estimated for this TPS. Gas resources that have the potential for additions to reserves in the next 30 years are estimated at a mean of 29.3 trillion cubic feet of gas (TCFG). Of this amount, 23.58 TCFG will come from coal-bed gas accumulations and 83.1 percent of this total is estimated to come from the Basin Fruitland CBG AU. The remaining 5.72 TCFG is allocated to continuous-type gas accumulations (5.64 TCFG) and conventional gas accumulations (0.08 TCFG). Although the Fruitland Fairway CBG AU has produced the most significant amount of coal-bed gas to date, the area of the AU is limited. New potentially productive wells will come from infill drilling, and the number of these wells will be limited by effective drainage area. Total natural gas liquids (NGL) that have the potential for additions to reserves in the next 30 years are estimated at a mean of 17.76 million barrels. Of this amount, 16.92 million barrels will come from the Pictured Cliffs Continuous Gas AU and the remainder from the Tertiary Conventional Gas AU.

  8. 46 CFR 109.103 - Requirements of the International Convention for Safety of Life at Sea, 1974.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Requirements of the International Convention for Safety of Life at Sea, 1974. 109.103 Section 109.103 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS General § 109.103 Requirements of the International...

  9. 46 CFR 109.103 - Requirements of the International Convention for Safety of Life at Sea, 1974.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Requirements of the International Convention for Safety of Life at Sea, 1974. 109.103 Section 109.103 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS General § 109.103 Requirements of the International...

  10. 46 CFR 109.103 - Requirements of the International Convention for Safety of Life at Sea, 1974.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Requirements of the International Convention for Safety of Life at Sea, 1974. 109.103 Section 109.103 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS General § 109.103 Requirements of the International...

  11. 46 CFR 109.103 - Requirements of the International Convention for Safety of Life at Sea, 1974.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Requirements of the International Convention for Safety of Life at Sea, 1974. 109.103 Section 109.103 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS General § 109.103 Requirements of the International...

  12. 46 CFR 109.103 - Requirements of the International Convention for Safety of Life at Sea, 1974.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Requirements of the International Convention for Safety of Life at Sea, 1974. 109.103 Section 109.103 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS OPERATIONS General § 109.103 Requirements of the International...

  13. Exploring the Relationships between the Use of Text Message Language and the Literacy Skills of Dyslexic and Normal Students

    ERIC Educational Resources Information Center

    Hsu, Jung-Lung

    2013-01-01

    It is apparent that individuals using text abbreviations as a written convention is a continuingly growing phenomenon. This special writing convention has been referred to as textism usage. However, there is surprisingly little research investigating the impacts of textism use on dyslexic children's cognitive abilities associated with literacy…

  14. Input-form data for the U.S. Geological Survey assessment of the Devonian and Mississippian Bakken and Devonian Three Forks Formations of the U.S. Williston Basin Province, 2013

    USGS Publications Warehouse

    ,; Gaswirth, Stephanie B.; Marra, Kristen R.; Cook, Troy A.; Charpentier, Ronald R.; Gautier, Donald L.; Higley, Debra K.; Klett, Timothy R.; Lewan, Michael D.; Lillis, Paul G.; Schenk, Christopher J.; Tennyson, Marilyn E.; Whidden, Katherine J.

    2013-01-01

    In 2013, the U.S. Geological Survey assessed the technically recoverable oil and gas resources of the Bakken and Three Forks Formations of the U.S. portion of the Williston Basin. The Bakken and Three Forks Formations were assessed as continuous and hypothetical conventional oil accumulations using a methodology similar to that used in the assessment of other continuous- and conventional-type assessment units throughout the United States. The purpose of this report is to provide supplemental documentation and information used in the Bakken-Three Forks assessment.

  15. Assessment of undiscovered oil and gas resources of the Anadarko Basin Province of Oklahoma, Kansas, Texas, and Colorado, 2010

    USGS Publications Warehouse

    Higley, D.K.; Gaswirth, S.B.; Abbott, M.M.; Charpentier, R.R.; Cook, T.A.; Ellis, G.S.; Gianoutsos, N.J.; Hatch, J.R.; Klett, T.R.; Nelson, Philip H.; Pawlewicz, M.J.; Pearson, O.N.; Pollastro, R.M.; Schenk, C.J.

    2011-01-01

    The U.S. Geological Survey, using a geoscience-based assessment methodology, estimated mean technically-recoverable undiscovered continuous and conventional resources that total 495 million barrels of oil, 27.5 trillion cubic feet of natural gas, and 410 million barrels of natural gas liquids in the Anadarko Basin Province; this assessment includes the Las Animas arch area of southeastern Colorado. The province is at a mature stage of exploration and development for conventional resources. Mean undiscovered continuous resources are estimated at 79 percent of oil, 90 percent of natural gas, and 81 percent of natural gas liquids in the province.

  16. Continuously-Variable Positive-Mesh Power Transmission

    NASA Technical Reports Server (NTRS)

    Johnson, J. L.

    1982-01-01

    Proposed transmission with continuously-variable speed ratio couples two mechanical trigonometric-function generators. Transmission is expected to handle higher loads than conventional variable-pulley drives; and, unlike variable pulley, positive traction through entire drive train with no reliance on friction to transmit power. Able to vary speed continuously through zero and into reverse. Possible applications in instrumentation where drive-train slippage cannot be tolerated.

  17. Assessment of undiscovered oil and gas resources in the Ventura Basin Province, California, 2016

    USGS Publications Warehouse

    Tennyson, Marilyn E.; Schenk, Christopher J.; Pitman, Janet K.; Lillis, Paul G.; Klett, Timothy R.; Brownfield, Michael E.; Finn, Thomas M.; Gaswirth, Stephanie B.; Hawkins, Sarah J.; Marra, Kristen R.; Mercier, Tracey J.; Le, Phuong A.; Leathers-Miller, Heidi M.

    2017-10-02

    The U.S. Geological Survey (USGS) completed a geology-based assessment of undiscovered, technically recoverable conventional and continuous oil and gas resources in the part of the Ventura Basin Province that lies onshore or within State waters (within 3 miles of the shoreline) of California (fig. 1). Conventional oil and gas resources are those that have migrated upward into structural or stratigraphic traps from deep zones where the oil and gas is generated; water is present below the oil or gas. Continuous accumulations, in contrast, are those in which oil or gas is pervasively present in essentially all wells that penetrate them, that may not be structurally or stratigraphically trapped, and that typically lack oil-water or gas-water contacts. They are commonly produced with well-stimulation technology, such as hydraulic fracturing, referred to as “unconventional.” The same stimulation technology, however, is also used in many conventionally trapped accumulations. We estimated both the likely range of oil and gas volumes remaining to be discovered in accumulations similar to existing conventional oil and gas fields in the Ventura Basin Province (previously assessed by Keller [1995] as 1,060 million barrels of oil [MMBO], 1,900 billion cubic feet of gas [BCFG], and 60 million barrels of natural gas liquids [MMBNGL]), and the potential for oil and gas that might be present in a continuous accumulation at extreme depth in the floor of the basin.

  18. Two-Year Safety and Efficacy Experience in Patients with Methotrexate-Resistant Active Rheumatoid Arthritis Treated with Etanercept and Conventional Disease-Modifying Anti-rheumatic Drugs in the Latin American Region

    PubMed Central

    Machado, Daniel A.; Guzman, Renato; Xavier, Ricardo M.; Simon, Jesus A.; Mele, Linda; Shen, Qi; Pedersen, Ronald; Kotak, Sameer; Vlahos, Bonnie

    2016-01-01

    Background: Although long-term data are available from biologic studies in North American/European populations with rheumatoid arthritis (RA), long-term findings in Latin American RA populations are limited. Objective: To examine long-term safety/efficacy of etanercept, methotrexate, and/or other disease-modifying anti-rheumatic drugs (DMARDs) in Latin American patients with moderate-to-severe active RA. Methods: In the first phase of this open-label study, patients were randomized to etanercept 50 mg weekly plus methotrexate or conventional DMARD (hydroxychloroquine or sulfasalazine) plus methotrexate for 24 weeks. At the start of the second phase (week 24), investigators selected a treatment regimen that included any combination/dosage of etanercept, methotrexate, hydroxychloroquine, or sulfasalazine based on previous treatment response, preference, and local product labeling, and was continued for the 104-week extension. Results: In the extension, in the group previously randomized to etanercept-plus-methotrexate therapy, etanercept was continued in 259/260 patients; methotrexate continued in 260/260; and hydroxychloroquine and sulfasalazine added in 8/260 and 3/260, respectively. In the group previously randomized to conventional DMARD-plus-methotrexate therapy, conventional DMARD was discontinued in 86/126 and etanercept added in 105/126. Among etanercept-exposed patients (total exposure, 798.1 patient-year [PY]), rates of adverse events, serious adverse events, and serious infections per PY were 1.7, 0.07, and 0.02 events per PY. In both groups, after treatment modification was permitted, clinical response rates and improvements in clinical/patient-reported outcomes from baseline were sustained to week 128. Conclusion: After investigators were permitted to modify treatment, etanercept was part of the treatment regimen in 95% of patients. Continuation or addition of etanercept in the 2-year extension resulted in a consistently good risk:benefit profile. Trial Registration: Open-Label Study Comparing Etanercept to Conventional Disease Modifying Antirheumatic Drug (DMARD) Therapy; ClinicalTrials.gov, number NCT00848354; https://clinicaltrials.gov/ct2/show/NCT00848354 PMID:27006728

  19. Embracing the quantum limit in silicon computing.

    PubMed

    Morton, John J L; McCamey, Dane R; Eriksson, Mark A; Lyon, Stephen A

    2011-11-16

    Quantum computers hold the promise of massive performance enhancements across a range of applications, from cryptography and databases to revolutionary scientific simulation tools. Such computers would make use of the same quantum mechanical phenomena that pose limitations on the continued shrinking of conventional information processing devices. Many of the key requirements for quantum computing differ markedly from those of conventional computers. However, silicon, which plays a central part in conventional information processing, has many properties that make it a superb platform around which to build a quantum computer. © 2011 Macmillan Publishers Limited. All rights reserved

  20. Incidence of tardive dyskinesia with atypical versus conventional antipsychotic medications: a prospective cohort study.

    PubMed

    Woods, Scott W; Morgenstern, Hal; Saksa, John R; Walsh, Barbara C; Sullivan, Michelle C; Money, Roy; Hawkins, Keith A; Gueorguieva, Ralitza V; Glazer, William M

    2010-04-01

    Most previous studies of the incidence of tardive dyskinesia with atypical antipsychotics compared with conventional antipsychotics have not had tardive dyskinesia as their primary focus. The current study aimed to compare the incidence of tardive dyskinesia with atypical vs conventional antipsychotics using methods similar to those from a previous prospective cohort study at our site in the 1980s. Three hundred fifty-two initially tardive dyskinesia-free psychiatric outpatients (diagnosed at baseline using the Structured Clinical Interview for DSM-IV) were examined for a new diagnosis of tardive dyskinesia (using the Abnormal Involuntary Movement Scale and Glazer-Morgenstern criteria) every 6 months for up to 4 years at a community mental health center. At baseline, subjects were receiving conventional antipsychotics only (23%), atypicals only (64%), or both (14%). Only 26 subjects had never received conventional antipsychotics. Baseline evaluations were conducted from November 2000 through May 2003. Follow-ups were conducted through February 2005. Compared with subjects treated with conventional antipsychotics alone since the previous visit, the adjusted tardive dyskinesia incidence rate-ratio for subjects treated with atypical antipsychotics alone was 0.68 (95% CI, 0.29-1.64). The incidence and prevalence of tardive dyskinesia was similar to previous findings at this site in the 1980s. The incidence of tardive dyskinesia with recent exposure to atypical antipsychotics alone was more similar to that for conventional antipsychotics than in most previous studies. Despite high penetration of atypical antipsychotics into clinical practice, the incidence and prevalence of tardive dyskinesia appeared relatively unchanged since the 1980s. Clinicians should continue to monitor for tardive dyskinesia, and researchers should continue to pursue efforts to treat or prevent it. Copyright 2010 Physicians Postgraduate Press, Inc.

  1. Reference Resources for Research and Continuing Education in Nursing.

    ERIC Educational Resources Information Center

    American Nurses' Association, Kansas City, MO.

    This booklet on reference resources for research and continuing education in nursing contains three papers that were presented at a program sponsored by the Interagency Council on Library Resources for Nursing held at the 1976 Convention of the American Nurses' Association. In "Awareness of Library Resources: A Characteristic of Professional…

  2. 40 CFR 469.19 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... technology (BCT). 469.19 Section 469.19 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ELECTRICAL AND ELECTRONIC COMPONENTS POINT SOURCE CATEGORY... by the application of the best conventional pollution control technology (BCT). Except as provided in...

  3. 40 CFR 469.29 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... technology (BCT). 469.29 Section 469.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ELECTRICAL AND ELECTRONIC COMPONENTS POINT SOURCE CATEGORY... attainable by the application of the best conventional pollution control technology (BCT). Except as provided...

  4. 40 CFR 469.19 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... technology (BCT). 469.19 Section 469.19 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ELECTRICAL AND ELECTRONIC COMPONENTS POINT SOURCE CATEGORY... by the application of the best conventional pollution control technology (BCT). Except as provided in...

  5. 40 CFR 469.19 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... technology (BCT). 469.19 Section 469.19 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ELECTRICAL AND ELECTRONIC COMPONENTS POINT SOURCE CATEGORY... by the application of the best conventional pollution control technology (BCT). Except as provided in...

  6. 40 CFR 469.29 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... technology (BCT). 469.29 Section 469.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ELECTRICAL AND ELECTRONIC COMPONENTS POINT SOURCE CATEGORY... attainable by the application of the best conventional pollution control technology (BCT). Except as provided...

  7. 40 CFR 469.29 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... technology (BCT). 469.29 Section 469.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) ELECTRICAL AND ELECTRONIC COMPONENTS POINT SOURCE CATEGORY... attainable by the application of the best conventional pollution control technology (BCT). Except as provided...

  8. Preliminary acclimation strategies for successful startup in conventional biofilters.

    PubMed

    Elías, Ana; Barona, Astrid; Gallastegi, Gorka; Rojo, Naiara; Gurtubay, Luis; Ibarra-Berastegi, Gabriel

    2010-08-01

    The question of how to obtain the best inocula for conventional biofilters arises when an acclimation/adaptation procedure is to be applied. Bearing in mind that no standardized procedure for acclimating inocula exists, certain preliminary strategies for obtaining an active inoculum from wastewater treatment sludge are proposed in this work. Toluene was the contaminant to be degraded. Concerning the prior separation of sludge phases, no obvious advantage was found in separating the supernatant phase of the sludge before acclimation. As far as a continuous or discontinuous acclimation mode is concerned, the latter is recommended for rapidly obtaining acclimated sludge samples by operating the system for no longer than 1 month. The continuous mode rendered similar degradation rates, although it required longer operating time. Nevertheless, the great advantage of the continuous system lay in the absence of daily maintenance and the ready availability of the activated sample.

  9. U.S. Geological Survey input-data forms for the assessment of the Spraberry Formation of the Midland Basin, Permian Basin Province, Texas, 2017

    USGS Publications Warehouse

    Marra, Kristen R.

    2017-10-24

    In 2017, the U.S. Geological Survey (USGS) completed an updated assessment of undiscovered, technically recoverable oil and gas resources in the Spraberry Formation of the Midland Basin (Permian Basin Province) in southwestern Texas (Marra and others, 2017). The Spraberry Formation was assessed using both the standard continuous (unconventional) and conventional methodologies established by the USGS for three assessment units (AUs): (1) Lower Spraberry Continuous Oil Trend AU, (2) Middle Spraberry Continuous Oil Trend AU, and (3) Northern Spraberry Conventional Oil AU. The revised assessment resulted in total estimated mean resources of 4,245 million barrels of oil, 3,112 billion cubic feet of gas, and 311 million barrels of natural gas liquids. The purpose of this report is to provide supplemental documentation of the input parameters used in the USGS 2017 Spraberry Formation assessment.

  10. Electronically commutated motors for vehicle applications

    NASA Astrophysics Data System (ADS)

    Echolds, E. F.

    1980-02-01

    Two permanent magnet electronically commutated motors for electric vehicle traction are discussed. One, based on existing technology, produces 23 kW (peak) at 26,000 rpm, and 11 kW continuous at 18,000 rpm. The motor has a conventional design: a four-pole permanent magnet rotor and a three-phase stator similar to those used on ordinary induction motors. The other, advanced technology motor, is rated at 27 kW (peak) at 14,000 rpm, and 11 kW continuous at 10,500 rpm. The machine employs a permanent magnet rotor and a novel ironless stator design in an axial air gap, homopolar configuration. Comparison of the new motors with conventional brush type machines indicates potential for substantial cost savings.

  11. Continuous flow microfluidic separation and processing of rare cells and bioparticles found in blood - A review.

    PubMed

    Antfolk, Maria; Laurell, Thomas

    2017-05-01

    Rare cells in blood, such as circulating tumor cells or fetal cells in the maternal circulation, posses a great prognostic or diagnostic value, or for the development of personalized medicine, where the study of rare cells could provide information to more specifically targeted treatments. When conventional cell separation methods, such as flow cytometry or magnetic activated cell sorting, have fallen short other methods are desperately sought for. Microfluidics have been extensively used towards isolating and processing rare cells as it offers possibilities not present in the conventional systems. Furthermore, microfluidic methods offer new possibilities for cell separation as they often rely on non-traditional biomarkers and intrinsic cell properties. This offers the possibility to isolate cell populations that would otherwise not be targeted using conventional methods. Here, we provide an extensive review of the latest advances in continuous flow microfluidic rare cell separation and processing with each cell's specific characteristics and separation challenges as a point of view. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Zoom microscope objective using electrowetting lenses.

    PubMed

    Li, Lei; Wang, Di; Liu, Chao; Wang, Qiong-Hua

    2016-02-08

    We report a zoom microscope objective which can achieve continuous zoom change and correct the aberrations dynamically. The objective consists of three electrowetting liquid lenses and two glass lenses. The magnification is changed by applying voltages on the three electrowetting lenses. Besides, the three electrowetting liquid lenses can play a role to correct the aberrations. A digital microscope based on the proposed objective is demonstrated. We analyzed the properties of the proposed objective. In contrast to the conventional objectives, the proposed objective can be tuned from ~7.8 × to ~13.2 × continuously. For our objective, the working distance is fixed, which means no movement parts are needed to refocus or change its magnification. Moreover, the zoom objective can be dynamically optimized for a wide range of wavelength. Using such an objective, the fabrication tolerance of the optical system is larger than that of a conventional system, which can decrease the fabrication cost. The proposed zoom microscope objective cannot only take place of the conventional objective, but also has potential application in the 3D microscopy.

  13. Comparison of performance of shell-and-tube heat exchangers with conventional segmental baffles and continuous helical baffle

    NASA Astrophysics Data System (ADS)

    Ahmed, Asif; Ferdous, Imam Ul.; Saha, Sumon

    2017-06-01

    In the present study, three-dimensional numerical simulation of two shell-and-tube heat exchangers (STHXs) with conventional segmental baffles (STHXsSB) and continuous helical baffle (STHXsHB) is carried out and a comparative study is performed based on the simulation results. Both of the STHXs contain 37 tubes inside a 500 mm long and 200 mm diameter shell and mass flow rate of shell-side fluid is varied from 0.5 kg/s to 2 kg/s. At first, physical and mathematical models are developed and numerically simulated using finite element method (FEM). For the validation of the computational model, shell-side average nusselt number (Nus) is calculated from the simulation results and compared with the available experimental results. The comparative study shows that STHXsHB has 72-127% higher heat transfer coefficient per unit pressure drop compared to the conventional STHXsSB for the same shell-side mass flow rate. Moreover, STHXsHB has 59-63% lower shell-side pressure drop than STHXsSB.

  14. Impacts of long-term no-tillage and conventional tillage management of spring wheat-lentil cropping systems in dryland Eastern Montana, USA, on fungi associated to soil aggregation

    USDA-ARS?s Scientific Manuscript database

    Lentil (Lens culinaris Medikus CV. Indianhead) used to replace fallow in spring-wheat (Triticum aestivum) rotation in the semi-arid Eastern Montana USA, may improve soil quality. We evaluate the 14 years influence of continuous wheat under no-tillage (WNT), fallow-wheat under conventional tillage (F...

  15. Circadian hormone profiles and insulin sensitivity in patients with Addison's disease: a comparison of continuous subcutaneous hydrocortisone infusion with conventional glucocorticoid replacement therapy.

    PubMed

    Björnsdottir, Sigridur; Øksnes, Marianne; Isaksson, Magnus; Methlie, Paal; Nilsen, Roy M; Hustad, Steinar; Kämpe, Olle; Hulting, Anna-Lena; Husebye, Eystein S; Løvås, Kristian; Nyström, Thomas; Bensing, Sophie

    2015-07-01

    Conventional glucocorticoid replacement therapy in patients with Addison's disease (AD) is unphysiological with possible adverse effects on mortality, morbidity and quality of life. The diurnal cortisol profile can likely be restored by continuous subcutaneous hydrocortisone infusion (CSHI). The aim of this study was to compare circadian hormone rhythms and insulin sensitivity in conventional thrice-daily regimen of glucocorticoid replacement therapy with CSHI treatment in patients with AD. An open, randomized, two-period, 12-week crossover multicentre trial in Norway and Sweden. Ten Norwegian patients were admitted for 24-h sampling of hormone profiles. Fifteen Swedish patients underwent euglycaemic-hyperinsulinaemic clamp. Thrice-daily regimen of oral hydrocortisone (OHC) and CSHI treatment. We measured the circadian rhythm of cortisol, adrenocorticotropic hormone (ACTH), growth hormone (GH), insulin-like growth factor-1, (IGF-1), IGF-binding protein-3 (IGFBP-3), glucose, insulin and triglycerides during OHC and CSHI treatment. Euglycaemic-hyperinsulinaemic clamp was used to assess insulin sensitivity. Continuous subcutaneous hydrocortisone infusion provided a more physiological circadian cortisol curve including a late-night cortisol surge. ACTH levels showed a near normal circadian variation for CSHI. CSHI prevented a continuous decrease in glucose during the night. No difference in insulin sensitivity was observed between the two treatment arms. Continuous subcutaneous hydrocortisone infusion replacement re-established a circadian cortisol rhythm and normalized the ACTH levels. Patients with CSHI replacement had a more stable night-time glucose level compared with OHC without compromising insulin sensitivity. Thus, restoring night-time cortisol levels might be advantageous for patients with AD. © 2015 John Wiley & Sons Ltd.

  16. Quality comparison of continuous steam sterilization segmented-flow aseptic processing versus conventional canning of whole and sliced mushrooms.

    PubMed

    Anderson, N M; Walker, P N

    2011-08-01

    This study was carried out to investigate segmented-flow aseptic processing of particle foods. A pilot-scale continuous steam sterilization unit capable of producing shelf stable aseptically processed whole and sliced mushrooms was developed. The system utilized pressurized steam as the heating medium to achieve high temperature-short time processing conditions with high and uniform heat transfer that will enable static temperature penetration studies for process development. Segmented-flow technology produced a narrower residence time distribution than pipe-flow aseptic processing; thus, whole and sliced mushrooms were processed only as long as needed to achieve the target F₀  = 7.0 min and were not overcooked. Continuous steam sterilization segmented-flow aseptic processing produced shelf stable aseptically processed mushrooms of superior quality to conventionally canned mushrooms. When compared to conventionally canned mushrooms, aseptically processed yield (weight basis) increased 6.1% (SD = 2.9%) and 6.6% (SD = 2.2%), whiteness (L) improved 3.1% (SD = 1.9%) and 4.7% (SD = 0.7%), color difference (ΔE) improved 6.0% (SD = 1.3%) and 8.5% (SD = 1.5%), and texture improved 3.9% (SD = 1.7%) and 4.6% (SD = 4.2%), for whole and sliced mushrooms, respectively. Segmented-flow aseptic processing eliminated a separate blanching step, eliminated the unnecessary packaging of water and promoted the use of bag-in-box and other versatile aseptic packaging methods. Segmented-flow aseptic processing is capable of producing shelf stable aseptically processed particle foods of superior quality to a conventionally canned product. This unique continuous steam sterilization process eliminates the need for a separate blanching step, reduces or eliminates the need for a liquid carrier, and promotes the use of bag-in-box and other versatile aseptic packaging methods. © 2011 Institute of Food Technologists®

  17. Accuracy of delta 18O isotope ratio measurements on the same sample by continuous-flow isotope-ratio mass spectrometry

    USDA-ARS?s Scientific Manuscript database

    The doubly labeled water method is considered the reference method to measure energy expenditure. Conventional mass spectrometry requires a separate aliquot of the same sample to be prepared and analyzed separately. With continuous-flow isotope-ratio mass spectrometry, the same sample could be analy...

  18. No major differences found between the effects of microwave-based and conventional heat treatment methods on two different liquid foods.

    PubMed

    Géczi, Gábor; Horváth, Márk; Kaszab, Tímea; Alemany, Gonzalo Garnacho

    2013-01-01

    Extension of shelf life and preservation of products are both very important for the food industry. However, just as with other processes, speed and higher manufacturing performance are also beneficial. Although microwave heating is utilized in a number of industrial processes, there are many unanswered questions about its effects on foods. Here we analyze whether the effects of microwave heating with continuous flow are equivalent to those of traditional heat transfer methods. In our study, the effects of heating of liquid foods by conventional and continuous flow microwave heating were studied. Among other properties, we compared the stability of the liquid foods between the two heat treatments. Our goal was to determine whether the continuous flow microwave heating and the conventional heating methods have the same effects on the liquid foods, and, therefore, whether microwave heat treatment can effectively replace conventional heat treatments. We have compared the colour, separation phenomena of the samples treated by different methods. For milk, we also monitored the total viable cell count, for orange juice, vitamin C contents in addition to the taste of the product by sensory analysis. The majority of the results indicate that the circulating coil microwave method used here is equivalent to the conventional heating method based on thermal conduction and convection. However, some results in the analysis of the milk samples show clear differences between heat transfer methods. According to our results, the colour parameters (lightness, red-green and blue-yellow values) of the microwave treated samples differed not only from the untreated control, but also from the traditional heat treated samples. The differences are visually undetectable, however, they become evident through analytical measurement with spectrophotometer. This finding suggests that besides thermal effects, microwave-based food treatment can alter product properties in other ways as well.

  19. No Major Differences Found between the Effects of Microwave-Based and Conventional Heat Treatment Methods on Two Different Liquid Foods

    PubMed Central

    Géczi, Gábor; Horváth, Márk; Kaszab, Tímea; Alemany, Gonzalo Garnacho

    2013-01-01

    Extension of shelf life and preservation of products are both very important for the food industry. However, just as with other processes, speed and higher manufacturing performance are also beneficial. Although microwave heating is utilized in a number of industrial processes, there are many unanswered questions about its effects on foods. Here we analyze whether the effects of microwave heating with continuous flow are equivalent to those of traditional heat transfer methods. In our study, the effects of heating of liquid foods by conventional and continuous flow microwave heating were studied. Among other properties, we compared the stability of the liquid foods between the two heat treatments. Our goal was to determine whether the continuous flow microwave heating and the conventional heating methods have the same effects on the liquid foods, and, therefore, whether microwave heat treatment can effectively replace conventional heat treatments. We have compared the colour, separation phenomena of the samples treated by different methods. For milk, we also monitored the total viable cell count, for orange juice, vitamin C contents in addition to the taste of the product by sensory analysis. The majority of the results indicate that the circulating coil microwave method used here is equivalent to the conventional heating method based on thermal conduction and convection. However, some results in the analysis of the milk samples show clear differences between heat transfer methods. According to our results, the colour parameters (lightness, red-green and blue-yellow values) of the microwave treated samples differed not only from the untreated control, but also from the traditional heat treated samples. The differences are visually undetectable, however, they become evident through analytical measurement with spectrophotometer. This finding suggests that besides thermal effects, microwave-based food treatment can alter product properties in other ways as well. PMID:23341982

  20. Financial competitiveness of organic agriculture on a global scale.

    PubMed

    Crowder, David W; Reganold, John P

    2015-06-16

    To promote global food and ecosystem security, several innovative farming systems have been identified that better balance multiple sustainability goals. The most rapidly growing and contentious of these systems is organic agriculture. Whether organic agriculture can continue to expand will likely be determined by whether it is economically competitive with conventional agriculture. Here, we examined the financial performance of organic and conventional agriculture by conducting a meta-analysis of a global dataset spanning 55 crops grown on five continents. When organic premiums were not applied, benefit/cost ratios (-8 to -7%) and net present values (-27 to -23%) of organic agriculture were significantly lower than conventional agriculture. However, when actual premiums were applied, organic agriculture was significantly more profitable (22-35%) and had higher benefit/cost ratios (20-24%) than conventional agriculture. Although premiums were 29-32%, breakeven premiums necessary for organic profits to match conventional profits were only 5-7%, even with organic yields being 10-18% lower. Total costs were not significantly different, but labor costs were significantly higher (7-13%) with organic farming practices. Studies in our meta-analysis accounted for neither environmental costs (negative externalities) nor ecosystem services from good farming practices, which likely favor organic agriculture. With only 1% of the global agricultural land in organic production, our findings suggest that organic agriculture can continue to expand even if premiums decline. Furthermore, with their multiple sustainability benefits, organic farming systems can contribute a larger share in feeding the world.

  1. Design of a Tunable, Room Temperature, Continuous-Wave Terahertz Source and Detector using Silicon Waveguides

    DTIC Science & Technology

    2008-01-30

    that will use conventional diode- or hotomultiplier-tube-based optical detectors , which are xtremely sensitive . . HEATING AND FREE-CARRIER IMITATIONS...CONTRACT NUMBER IN-HOUSE Design of a tunable, room temperature, continuous-wave terahertz source and detector using silicon waveguides 5b. GRANT...B 261Design of a tunable, room temperature, continuous-wave terahertz source and detector using silicon waveguides T. Baehr-Jones,1,* M. Hochberg,1,3

  2. The Next Generation: Access and Opportunity in Continuing Higher Education. Proceedings of the Annual Meeting of the Association for Continuing Higher Education (70th, Nashville, Tennessee, November 8-11, 2008)

    ERIC Educational Resources Information Center

    Barrineau, Irene T., Ed.

    2008-01-01

    These proceedings record the 70th Annual Conference and Meeting of ACHE (Association for Continuing Higher Education) held at the Gaylord Opryland Resort and Convention Center in Nashville, Tennessee. The conference theme, "The Next Generation: Access and Opportunity in CHE" challenged attendees to think about the coming new age and its…

  3. Further trials of roll-feed, high-temperature dryers for 8/4 southern pine

    Treesearch

    P. Koch

    1975-01-01

    Studs cut from veneer cores and dried by four configurations of roll-feeding mechaniams (for a continuous kiln like a roll-feed veneer dryer) were compared to conventionally stickered studs. Roll-dried studs averaged leas crook (0.14 in.), bow (0.17), and twist (0.16) than those conventionally suckered (0.22, 0.26, and 0.34 inch, respectively). The data seemed to favor...

  4. Microfluidic Synthesis and Biological Evaluation of Photothermal Biodegradable Copper Sulfide Nanoparticles.

    PubMed

    Ortiz de Solorzano, Isabel; Prieto, Martín; Mendoza, Gracia; Alejo, Teresa; Irusta, Silvia; Sebastian, Victor; Arruebo, Manuel

    2016-08-24

    The continuous synthesis of biodegradable photothermal copper sulfide nanoparticles has been carried out with the aid of a microfluidic platform. A comparative physicochemical characterization of the resulting products from the microreactor and from a conventional batch reactor has been performed. The microreactor is able to operate in a continuous manner and with a 4-fold reduction in the synthesis times compared to that of the conventional batch reactor producing nanoparticles with the same physicochemical requirements. Biodegradation subproducts obtained under simulated physiological conditions have been identified, and a complete cytotoxicological analysis on different cell lines was performed. The photothermal effect of those nanomaterials has been demonstrated in vitro as well as their ability to generate reactive oxygen species.

  5. EEG Monitoring Technique Influences the Management of Hypoxic-Ischemic Seizures in Neonates Undergoing Therapeutic Hypothermia.

    PubMed

    Jan, Saber; Northington, Frances J; Parkinson, Charlamaine M; Stafstrom, Carl E

    2017-01-01

    Electroencephalogram (EEG) monitoring techniques for neonatal hypoxia-ischemia (HI) are evolving over time, and the specific type of EEG utilized could influence seizure diagnosis and management. We examined whether the type of EEG performed affected seizure treatment decisions (e.g., the choice and number of antiseizure drugs [ASDs]) in therapeutic hypothermia-treated neonates with HI from 2007 to 2015 in the Johns Hopkins Hospital Neonatal Intensive Care Unit. During this period, 3 different EEG monitoring protocols were utilized: Period 1 (2007-2009), single, brief conventional EEG (1 h duration) at a variable time during therapeutic hypothermia treatment, i.e., ordered when a seizure was suspected; Period 2 (2009-2013), single, brief conventional EEG followed by amplitude-integrated EEG for the duration of therapeutic hypothermia treatment and another brief conventional EEG after rewarming; and Period 3 (2014-2015), continuous video-EEG (cEEG) for the duration of therapeutic hypothermia treatment (72 h) plus for an additional 12 h during and after rewarming. One hundred and sixty-two newborns were included in this retrospective cohort study. As a function of the type and duration of EEG monitoring, we assessed the risk (likelihood) of receiving no ASD, at least 1 ASD, or ≥2 ASDs. We found that the risk of a neonate being prescribed an ASD was 46% less during Period 3 (cEEG) than during Period 1 (brief conventional EEG only) (95% CI 6-69%, p = 0.03). After adjusting for initial EEG and MRI results, compared with Period 1, there was a 38% lower risk of receiving an ASD during Period 2 (95% CI: 9-58%, p = 0.02) and a 67% lower risk during Period 3 (95% CI: 23-86%, p = 0.01). The risk ratio of receiving ≥2 ASDs was not significantly different across the 3 periods. In conclusion, in addition to the higher sensitivity and specificity of continuous video-EEG monitoring, fewer infants are prescribed an ASD when undergoing continuous forms of EEG monitoring (aEEG or cEEG) than those receiving conventional EEG. We recommend that use of continuous video-EEG be considered whenever possible, both to treat seizures more specifically and to avoid overtreatment. © 2017 S. Karger AG, Basel.

  6. Distributed acoustic sensing system based on continuous wide-band ultra-weak fiber Bragg grating array

    NASA Astrophysics Data System (ADS)

    Tang, Jianguan; Li, Liang; Guo, Huiyong; Yu, Haihu; Wen, Hongqiao; Yang, Minghong

    2017-04-01

    A distributed acoustic sensing system (DAS) with low-coherence ASE and Michelson interferometer based on continuous width-band ultra-weak fiber Bragg grating (UW-FBG) array is proposed and experimentally demonstrated. The experimental result shows that the proposed system has better performance in detecting acoustic waves than the conventional hydrophone.

  7. Organ culture in 3-dimensional matrix: in vitro model for evaluating biological compliance of synthetic meshes for abdominal wall repair.

    PubMed

    Dasdia, T; Bazzaco, S; Bottero, L; Buffa, R; Ferrero, S; Campanelli, G; Dolfini, E

    1998-01-01

    A new in vitro method to evaluate the early critical interactions between synthetic prosthetic materials and growing tissues is reported. The correct spatial organization and proper cell to cell interaction required to mimic the in vivo environment was obtained in a 3-dimensional (3-D) embryo organ culture. The clot formed by plasma and chick-embryo extract provided a natural 3-D extracellular matrix that was able to support the growth and differentiation of intestinal tissue dissected from 12-day-old chick embryos. Different materials used for the repair of abdominal wall defects were taken as standards; all the prosthetic materials were devoid of any evident cytotoxic potential over a 10-day culture period, so they did not interfere with the organogenesis process. A polyglactin mesh (Vicryl) was fully incorporated into the growing tissue, but early signs of its degradation were detectable. The biologically inert materials polyethylene terephthalate (Mersilene) and polypropylene (Marlex, Prolene, and Herniamesh) retained their structural integrity when incubated with cultured tissue at 37 degrees C, and they did not hinder cellular proliferation or fibroblast migration. However, the outgrowth behavior was very different while the connective tissue invaded the interstices of the polyethylene terephthalate mesh; the explants and the migrating cells were repelled by hydrophobic polypropylene meshes. These findings are in agreement with other reported results in in vivo studies. Therefore, this method can be considered as reliable and predictable for the evaluation of biopolymers.

  8. Retzus-sparing robotic-assisted laparoscopic radical prostatectomy: a step-by-step technique description of this first brazilian experience.

    PubMed

    Tobias-Machado, Marcos; Nunes-Silva, Igor; Hidaka, Alexandre Kiyoshi; Sato, Leticia Lumy Kanawa; Almeida, Roberto; Colombo, Jose Roberto; Zampolli, Hamilton de Campos; Pompeo, Antonio Carlos Lima

    2016-01-01

    Retzus-sparing robotic-assisted radical prostatectomy(RARP) is a newly approach that preserve the Retzus structures and provide better recovery of continence and erectile function. In Brazil, this approach has not yet been pre¬viously reported. Our goal is to describe Step-by-Step the Retzus-sparing RARP surgical technique and report our first Brazilian experience. We present a case of a 60-year-old white man with low risk prostate cancer. Surgical materials were four arms Da Vinci robotic platform system, six transperitoneal portals, two prolene wires and Polymer Clips. This surgical tech¬nique was step-by-step described according to Galfano et al. One additional step was added as a modification of Galfano et al. Primary technique description: The closure of the Denovellier fascia. We have operated one patient with this technique. The operative time was 180minutes, console time was135 min, the blood loss was 150ml, none perioperative or postoperative complications was found, hospital stay of 01 day. The anatomopathological classification revealed a pT2aN0M0 specimen with free surgical margins. The patient achieved continence immediately after bladder stent retrieval. Full erection reported after 30 days of surgery. Retzus-sparing RARP approach is feasible and reproducible. However, further comparative studies are neces¬sary to demonstrate potential benefits in continence and sexual outcomes over the standard approaches. Copyright® by the International Brazilian Journal of Urology.

  9. Air Pollution: Current and Future Challenges

    EPA Pesticide Factsheets

    Despite the dramatic progress to date, air pollution continues to threaten Americans’ health and welfare. The main obstacles are climate change, conventional air pollution, and ozone layer depletion.

  10. Antibiotic Dosing in Continuous Renal Replacement Therapy.

    PubMed

    Shaw, Alexander R; Mueller, Bruce A

    2017-07-01

    Appropriate antibiotic dosing is critical to improve outcomes in critically ill patients with sepsis. The addition of continuous renal replacement therapy makes achieving appropriate antibiotic dosing more difficult. The lack of continuous renal replacement therapy standardization results in treatment variability between patients and may influence whether appropriate antibiotic exposure is achieved. The aim of this study was to determine if continuous renal replacement therapy effluent flow rate impacts attaining appropriate antibiotic concentrations when conventional continuous renal replacement therapy antibiotic doses were used. This study used Monte Carlo simulations to evaluate the effect of effluent flow rate variance on pharmacodynamic target attainment for cefepime, ceftazidime, levofloxacin, meropenem, piperacillin, and tazobactam. Published demographic and pharmacokinetic parameters for each antibiotic were used to develop a pharmacokinetic model. Monte Carlo simulations of 5000 patients were evaluated for each antibiotic dosing regimen at the extremes of Kidney Disease: Improving Global Outcomes guidelines recommended effluent flow rates (20 and 35 mL/kg/h). The probability of target attainment was calculated using antibiotic-specific pharmacodynamic targets assessed over the first 72 hours of therapy. Most conventional published antibiotic dosing recommendations, except for levofloxacin, reach acceptable probability of target attainment rates when effluent rates of 20 or 35 mL/kg/h are used. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  11. Continuous glucose monitoring in acute coronary syndrome.

    PubMed

    Rodríguez-Quintanilla, Karina Alejandra; Lavalle-González, Fernando Javier; Mancillas-Adame, Leonardo Guadalupe; Zapata-Garrido, Alfonso Javier; Villarreal-Pérez, Jesús Zacarías; Tamez-Pérez, Héctor Eloy

    2013-01-01

    Diabetes mellitus is an independent risk factor for cardiovascular disease. To compare the efficacy of devices for continuous glucose monitoring and capillary glucose monitoring in hospitalized patients with acute coronary syndrome using the following parameters: time to achieve normoglycemia, period of time in normoglycemia, and episodes of hypoglycemia. We performed a pilot, non-randomized, unblinded clinical trial that included 16 patients with acute coronary artery syndrome, a capillary or venous blood glucose ≥ 140 mg/dl, and treatment with a continuous infusion of fast acting human insulin. These patients were randomized into 2 groups: a conventional group, in which capillary measurement and recording as well as insulin adjustment were made every 4h, and an intervention group, in which measurement and recording as well as insulin adjustment were made every hour with a subcutaneous continuous monitoring system. Student's t-test was applied for mean differences and the X(2) test for qualitative variables. We observed a statistically significant difference in the mean time for achieving normoglycemia, favoring the conventional group with a P = 0.02. Continuous monitoring systems are as useful as capillary monitoring for achieving normoglycemia. Copyright © 2012 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  12. First experimental feasibility study of VIPIC: a custom-made detector for X-ray speckle measurements

    PubMed Central

    Rumaiz, Abdul K.; Siddons, D. Peter; Deptuch, Grzegorz; Maj, Piotr; Kuczewski, Anthony J.; Carini, Gabriella A.; Narayanan, Suresh; Dufresne, Eric M.; Sandy, Alec; Bradford, Robert; Fluerasu, Andrei; Sutton, Mark

    2016-01-01

    The Vertically Integrated Photon Imaging Chip (VIPIC) was custom-designed for X-ray photon correlation spectroscopy, an application in which occupancy per pixel is low but high time resolution is needed. VIPIC operates in a sparsified streaming mode in which each detected photon is immediately read out as a time- and position-stamped event. This event stream can be fed directly to an autocorrelation engine or accumulated to form a conventional image. The detector only delivers non-zero data (sparsified readout), greatly reducing the communications overhead typical of conventional frame-oriented detectors such as charge-coupled devices or conventional hybrid pixel detectors. This feature allows continuous acquisition of data with timescales from microseconds to hours. In this work VIPIC has been used to measure X-ray photon correlation spectroscopy data on polystyrene latex nano-colliodal suspensions in glycerol and on colloidal suspensions of silica spheres in water. Relaxation times of the nano-colloids have been measured for different temperatures. These results demonstrate that VIPIC can operate continuously in the microsecond time frame, while at the same time probing longer timescales. PMID:26917126

  13. Non-Contact Smartphone-Based Monitoring of Thermally Stressed Structures

    PubMed Central

    Ozturk, Turgut; Mas, David; Rizzo, Piervincenzo

    2018-01-01

    The in-situ measurement of thermal stress in beams or continuous welded rails may prevent structural anomalies such as buckling. This study proposed a non-contact monitoring/inspection approach based on the use of a smartphone and a computer vision algorithm to estimate the vibrating characteristics of beams subjected to thermal stress. It is hypothesized that the vibration of a beam can be captured using a smartphone operating at frame rates higher than conventional 30 Hz, and the first few natural frequencies of the beam can be extracted using a computer vision algorithm. In this study, the first mode of vibration was considered and compared to the information obtained with a conventional accelerometer attached to the two structures investigated, namely a thin beam and a thick beam. The results show excellent agreement between the conventional contact method and the non-contact sensing approach proposed here. In the future, these findings may be used to develop a monitoring/inspection smartphone application to assess the axial stress of slender structures, to predict the neutral temperature of continuous welded rails, or to prevent thermal buckling. PMID:29670034

  14. Non-Contact Smartphone-Based Monitoring of Thermally Stressed Structures.

    PubMed

    Sefa Orak, Mehmet; Nasrollahi, Amir; Ozturk, Turgut; Mas, David; Ferrer, Belen; Rizzo, Piervincenzo

    2018-04-18

    The in-situ measurement of thermal stress in beams or continuous welded rails may prevent structural anomalies such as buckling. This study proposed a non-contact monitoring/inspection approach based on the use of a smartphone and a computer vision algorithm to estimate the vibrating characteristics of beams subjected to thermal stress. It is hypothesized that the vibration of a beam can be captured using a smartphone operating at frame rates higher than conventional 30 Hz, and the first few natural frequencies of the beam can be extracted using a computer vision algorithm. In this study, the first mode of vibration was considered and compared to the information obtained with a conventional accelerometer attached to the two structures investigated, namely a thin beam and a thick beam. The results show excellent agreement between the conventional contact method and the non-contact sensing approach proposed here. In the future, these findings may be used to develop a monitoring/inspection smartphone application to assess the axial stress of slender structures, to predict the neutral temperature of continuous welded rails, or to prevent thermal buckling.

  15. 15 CFR 715.3 - Declarations returned without action by BIS.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING UNSCHEDULED DISCRETE ORGANIC CHEMICALS (UDOCs) § 715.3 Declarations returned...

  16. 15 CFR 715.3 - Declarations returned without action by BIS.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING UNSCHEDULED DISCRETE ORGANIC CHEMICALS (UDOCs) § 715.3 Declarations returned...

  17. 15 CFR 715.3 - Declarations returned without action by BIS.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING UNSCHEDULED DISCRETE ORGANIC CHEMICALS (UDOCs) § 715.3 Declarations returned...

  18. 15 CFR 715.3 - Declarations returned without action by BIS.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING UNSCHEDULED DISCRETE ORGANIC CHEMICALS (UDOCs) § 715.3 Declarations returned...

  19. 15 CFR 716.9 - Report of inspection-related costs.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS... records, and costs associated with shutting down chemical production or processing during inspections, if...

  20. 15 CFR 717.4 - Report of inspection-related costs.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...), costs of producing records, and costs associated with shutting down chemical production or processing...

  1. 15 CFR 716.9 - Report of inspection-related costs.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS... records, and costs associated with shutting down chemical production or processing during inspections, if...

  2. Disappearance of T Cell-Mediated Rejection Despite Continued Antibody-Mediated Rejection in Late Kidney Transplant Recipients

    PubMed Central

    Chang, Jessica; Famulski, Konrad; Hidalgo, Luis G.; Salazar, Israel D.R.; Merino Lopez, Maribel; Matas, Arthur; Picton, Michael; de Freitas, Declan; Bromberg, Jonathan; Serón, Daniel; Sellarés, Joana; Einecke, Gunilla; Reeve, Jeff

    2015-01-01

    The prevalent renal transplant population presents an opportunity to observe the adaptive changes in the alloimmune response over time, but such studies have been limited by uncertainties in the conventional biopsy diagnosis of T cell-mediated rejection (TCMR) and antibody-mediated rejection (ABMR). To circumvent these limitations, we used microarrays and conventional methods to investigate rejection in 703 unselected biopsies taken 3 days to 35 years post-transplant from North American and European centers. Using conventional methods, we diagnosed rejection in 205 biopsy specimens (28%): 67 pure TCMR, 110 pure ABMR, and 28 mixed (89 designated borderline). Using microarrays, we diagnosed rejection in 228 biopsy specimens (32%): 76 pure TCMR, 124 pure ABMR, and 28 mixed (no borderline). Molecular assessment confirmed most conventional diagnoses (agreement was 90% for TCMR and 83% for ABMR) but revealed some errors, particularly in mixed rejection, and improved prediction of failure. ABMR was strongly associated with increased graft loss, but TCMR was not. ABMR became common in biopsy specimens obtained >1 year post-transplant and continued to appear in all subsequent intervals. TCMR was common early but progressively disappeared over time. In 108 biopsy specimens obtained 10.2–35 years post-transplant, TCMR defined by molecular and conventional features was never observed. We conclude that the main cause of kidney transplant failure is ABMR, which can present even decades after transplantation. In contrast, TCMR disappears by 10 years post-transplant, implying that a state of partial adaptive tolerance emerges over time in the kidney transplant population. PMID:25377077

  3. Financial competitiveness of organic agriculture on a global scale

    PubMed Central

    Crowder, David W.; Reganold, John P.

    2015-01-01

    To promote global food and ecosystem security, several innovative farming systems have been identified that better balance multiple sustainability goals. The most rapidly growing and contentious of these systems is organic agriculture. Whether organic agriculture can continue to expand will likely be determined by whether it is economically competitive with conventional agriculture. Here, we examined the financial performance of organic and conventional agriculture by conducting a meta-analysis of a global dataset spanning 55 crops grown on five continents. When organic premiums were not applied, benefit/cost ratios (−8 to −7%) and net present values (−27 to −23%) of organic agriculture were significantly lower than conventional agriculture. However, when actual premiums were applied, organic agriculture was significantly more profitable (22–35%) and had higher benefit/cost ratios (20–24%) than conventional agriculture. Although premiums were 29–32%, breakeven premiums necessary for organic profits to match conventional profits were only 5–7%, even with organic yields being 10–18% lower. Total costs were not significantly different, but labor costs were significantly higher (7–13%) with organic farming practices. Studies in our meta-analysis accounted for neither environmental costs (negative externalities) nor ecosystem services from good farming practices, which likely favor organic agriculture. With only 1% of the global agricultural land in organic production, our findings suggest that organic agriculture can continue to expand even if premiums decline. Furthermore, with their multiple sustainability benefits, organic farming systems can contribute a larger share in feeding the world. PMID:26034271

  4. Annular-Cross-Section CFE Chamber

    NASA Technical Reports Server (NTRS)

    Sharnez, Rizwan; Sammons, David W.

    1994-01-01

    Proposed continuous-flow-electrophoresis (CFE) chamber of annular cross section offers advantages over conventional CFE chamber, and wedge-cross-section chamber described in "Increasing Sensitivity in Continuous-Flow Electrophoresis" (MFS-26176). In comparison with wedge-shaped chamber, chamber of annular cross section virtually eliminates such wall effects as electro-osmosis and transverse gradients of velocity. Sensitivity enhanced by incorporating gradient maker and radial (collateral) flow.

  5. Reflexive convention: civil partnership, marriage and family.

    PubMed

    Heaphy, Brian

    2017-09-14

    Drawing on an analysis of qualitative interview data from a study of formalized same-sex relationships (civil partnerships) this paper examines the enduring significance of marriage and family as social institutions. In doing so, it intervenes in current debates in the sociology of family and personal life about how such institutions are undermined by reflexivity or bolstered by convention. Against the backdrop of dominating sociological frames for understanding the links between the changing nature of marriage and family and same-sex relationship recognition, the paper analyses the diverse and overlapping ways (including the simple, relational, strategic, ambivalent and critical ways) in which same-sex partners reflexively constructed and engaged with marriage and family conventions. My analysis suggests that instead of viewing reflexivity and convention as mutually undermining, as some sociologists of family and personal life do, it is insightful to explore how diverse forms of reflexivity and convention interact in everyday life to reconfigure the social institutions of marriage and family, but do not undermine them as such. I argue the case for recognizing the ways in which 'reflexive convention', or reflexive investment in convention, contributes to the continuing significance of marriage and family as social institutions. © London School of Economics and Political Science 2017.

  6. Conventionalism, structuralism and neo-Kantianism in Poincaré's philosophy of science

    NASA Astrophysics Data System (ADS)

    Ivanova, Milena

    2015-11-01

    Poincaré is well known for his conventionalism and structuralism. However, the relationship between these two theses and their place in Poincaré's epistemology of science remain puzzling. In this paper I show the scope of Poincaré's conventionalism and its position in Poincaré's hierarchical approach to scientific theories. I argue that for Poincaré scientific knowledge is relational and made possible by synthetic a priori, empirical and conventional elements, which, however, are not chosen arbitrarily. By examining his geometric conventionalism, his hierarchical account of science and defence of continuity in theory change, I argue that Poincaré defends a complex structuralist position based on synthetic a priori and conventional elements, the mind-dependence of which precludes epistemic access to mind-independent structures. The object of mathematical theories is not to reveal to us the real nature of things; that would be an unreasonable claim. Their only object is to coordinate the physical laws with which physical experiments make us acquainted, the enunciation of which, without the aid of mathematics, would be unable to effect. (Poincaré, 2001, 117)

  7. En Bloc Hilar Dissection of the Right Hepatic Artery in Continuity with the Bile Duct: a Technique to Reduce Biliary Complications After Adult Living-Donor Liver Transplantation.

    PubMed

    Abu-Gazala, Samir; Olthoff, Kim M; Goldberg, David S; Shaked, Abraham; Abt, Peter L

    2016-04-01

    Techniques that preserve the right hepatic artery and the common bile duct in continuity during the dissection may be associated with lower rates of biliary complications in living-donor liver transplants. This study sought to determine whether en bloc hilar dissections were associated with fewer biliary complications in living-donor liver transplants. This was a retrospective review of 41 adult LDLTs performed in a single, liver transplant center between February 2007 and September 2014. The primary outcome of interest was the occurrence of at least one of the following biliary complications: anastomotic leak, stricture, or biloma. The primary predictor of interest was the hilar dissection technique: conventional hilar dissection vs. en bloc hilar dissection. A total of 41 LDLTs were identified, 24 had a conventional, and 17 an en bloc hilar biliary dissection. The occurrence of any biliary complication was significantly more common in the conventional hilar dissection group compared to the en bloc hilar dissection group (66.7 vs. 35.3%, respectively, p = 0.047). In particularly, anastomotic strictures were significantly more common in the conventional hilar dissection group compared to the en bloc hilar dissection group (54.2 vs. 23.5%., respectively, p = 0.049). En bloc hilar dissection technique may decrease biliary complication rates in living donor liver transplants.

  8. Wavelet transforms with discrete-time continuous-dilation wavelets

    NASA Astrophysics Data System (ADS)

    Zhao, Wei; Rao, Raghuveer M.

    1999-03-01

    Wavelet constructions and transforms have been confined principally to the continuous-time domain. Even the discrete wavelet transform implemented through multirate filter banks is based on continuous-time wavelet functions that provide orthogonal or biorthogonal decompositions. This paper provides a novel wavelet transform construction based on the definition of discrete-time wavelets that can undergo continuous parameter dilations. The result is a transformation that has the advantage of discrete-time or digital implementation while circumventing the problem of inadequate scaling resolution seen with conventional dyadic or M-channel constructions. Examples of constructing such wavelets are presented.

  9. Effects of conventional welding and laser welding on the tensile strength, ultimate tensile strength and surface characteristics of two cobalt-chromium alloys: a comparative study.

    PubMed

    Madhan Kumar, Seenivasan; Sethumadhava, Jayesh Raghavendra; Anand Kumar, Vaidyanathan; Manita, Grover

    2012-06-01

    The purpose of this study was to evaluate the efficacy of laser welding and conventional welding on the tensile strength and ultimate tensile strength of the cobalt-chromium alloy. Samples were prepared with two commercially available cobalt-chromium alloys (Wironium plus and Diadur alloy). The samples were sectioned and the broken fragments were joined using Conventional and Laser welding techniques. The welded joints were subjected to tensile and ultimate tensile strength testing; and scanning electron microscope to evaluate the surface characteristics at the welded site. Both on laser welding as well as on conventional welding technique, Diadur alloy samples showed lesser values when tested for tensile and ultimate tensile strength when compared to Wironium alloy samples. Under the scanning electron microscope, the laser welded joints show uniform welding and continuous molt pool all over the surface with less porosity than the conventionally welded joints. Laser welding is an advantageous method of connecting or repairing cast metal prosthetic frameworks.

  10. Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems.

    PubMed

    An, Jiwoo; Trujillo-Rodríguez, María J; Pino, Verónica; Anderson, Jared L

    2017-06-02

    The development of rapid, convenient, and high throughput sample preparation approaches such as liquid phase microextraction techniques have been continuously developed over the last decade. More recently, significant attention has been given to the replacement of conventional organic solvents used in liquid phase microextraction techniques in order to reduce toxic waste and to improve selectivity and/or extraction efficiency. With these objectives, non-conventional solvents have been explored in liquid phase microextraction and aqueous biphasic systems. The utilized non-conventional solvents include ionic liquids, magnetic ionic liquids, and deep eutectic solvents. They have been widely used as extraction solvents or additives in various liquid phase microextraction modes including dispersive liquid-liquid microextraction, single-drop microextraction, hollow fiber-liquid phase microextraction, as well as in aqueous biphasic systems. This review provides an overview into the use of non-conventional solvents in these microextraction techniques in the past 5 years (2012-2016). Analytical applications of the techniques are also discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. How to approach ballast water management in European seas

    NASA Astrophysics Data System (ADS)

    David, Matej; Gollasch, Stephan

    2018-02-01

    The latest research continues to show that the ballast water issue is very complex, which makes it very challenging to manage. In 2004, the International Convention for the Control and Management of Ships' Ballast Water and Sediments (BWM Convention) was adopted to globally harmonize action against the transfer of harmful aquatic organisms and pathogens via ships' ballast water and related sediments. Analyses of the BWM Convention requirements, conducted through different research projects mainly aiming to provide support for the implementation of the BWM Convention, have shown that there are different steps countries need to take and that there are still some open issues which need to be solved. This paper presents some of the main issues identified and the core theoretical and applied measures required to solve these issues, with the aim to support more efficient and coordinated implementation of the BWM Convention requirements in EU seas. The approaches recommended here for the EU may be universally interesting for similar application in other areas of the world.

  12. 15 CFR 712.8 - Declarations and reports returned without action by BIS.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING SCHEDULE 1 CHEMICALS § 712.8 Declarations and reports returned...

  13. 15 CFR 714.5 - Declarations and reports returned without action by BIS.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING SCHEDULE 3 CHEMICALS § 714.5 Declarations and reports returned...

  14. 15 CFR 713.6 - Declarations and reports returned without action by BIS.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING SCHEDULE 2 CHEMICALS § 713.6 Declarations and reports returned...

  15. 26 CFR 521.110 - Government wages, salaries, pensions and similar remuneration.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS DENMARK General Income Tax Taxation of Nonresident... residents therein. As to the taxation generally of compensation of alien employees of foreign governments...

  16. 15 CFR 712.8 - Declarations and reports returned without action by BIS.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING SCHEDULE 1 CHEMICALS § 712.8 Declarations and reports returned...

  17. 15 CFR 713.6 - Declarations and reports returned without action by BIS.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING SCHEDULE 2 CHEMICALS § 713.6 Declarations and reports returned...

  18. 15 CFR 714.5 - Declarations and reports returned without action by BIS.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING SCHEDULE 3 CHEMICALS § 714.5 Declarations and reports returned...

  19. 50 CFR 35.13 - Access to State and private lands.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM WILDERNESS PRESERVATION AND MANAGEMENT General Rules § 35.13... accepted, conventional, contemporary modes of travel in said vicinity. Use will be consistent with...

  20. 49 CFR 572.111 - General description.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Side Impact Hybrid Dummy... before being used in vehicle tests specified in Standard 201. (c) Disassembly, inspection and assembly..., “Sign Convention for Vehicle Crash Testing.” ...

  1. 15 CFR 720.3 - Final decision on administrative action denying export privileges.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS DENIAL OF EXPORT PRIVILEGES § 720.3 Final decision on administrative action...

  2. 15 CFR 720.3 - Final decision on administrative action denying export privileges.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS DENIAL OF EXPORT PRIVILEGES § 720.3 Final decision on administrative action...

  3. 26 CFR 521.110 - Government wages, salaries, pensions and similar remuneration.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS DENMARK General Income Tax Taxation of Nonresident Aliens Who... residents therein. As to the taxation generally of compensation of alien employees of foreign governments...

  4. Crew Procedures for Continuous Descent Arrivals Using Conventional Guidance

    NASA Technical Reports Server (NTRS)

    Oseguera-Lohr, Rosa M.; Williams, David H.; Lewis, Elliot T,

    2007-01-01

    This paper presents results from a simulation study which investigated the use of Continuous Descent Arrival (CDA) procedures for conducting a descent through a busy terminal area, using conventional transport-category automation. This research was part of the Low Noise Flight Procedures (LNFP) element within the Quiet Aircraft Technology (QAT) Project, that addressed development of flight guidance, and supporting pilot and Air Traffic Control (ATC) procedures for low noise operations. The procedures and chart were designed to be easy to understand, and to make it easy for the crew to make changes via the Flight Management Computer Control-Display Unit (FMC-CDU) to accommodate changes from ATC. The test runs were intended to represent situations typical of what exists in many of today's terminal areas, including interruptions to the descent in the form of clearances issued by ATC.

  5. Interorganizational Training Opportunities for Conventional US Army Forces

    DTIC Science & Technology

    2013-03-26

    INTERORGAHIZATIOIW. TRAINING ~IllES FOR CONVENTIONAL US ARM’f FORCES (:1111~1 $1<Jit> ""’- CDf1’ S C ’ummond and Stoff Coli~’< Murin.: CtXpS t’JII...the contemporary operating environment are of great value to units in training. The partnered lessons learned in conjunction with a continued...requirements outlined in the National Security Strategy and the intent of the Commander in Chief.1 The President of the United States in conjunction with the

  6. Microbial Community Structure and Enzyme Activities in Semiarid Agricultural Soils

    NASA Astrophysics Data System (ADS)

    Acosta-Martinez, V. A.; Zobeck, T. M.; Gill, T. E.; Kennedy, A. C.

    2002-12-01

    The effect of agricultural management practices on the microbial community structure and enzyme activities of semiarid soils of different textures in the Southern High Plains of Texas were investigated. The soils (sandy clay loam, fine sandy loam and loam) were under continuous cotton (Gossypium hirsutum L.) or in rotations with peanut (Arachis hypogaea L.), sorghum (Sorghum bicolor L.) or wheat (Triticum aestivum L.), and had different water management (irrigated or dryland) and tillage (conservation or conventional). Microbial community structure was investigated using fatty acid methyl ester (FAME) analysis by gas chromatography and enzyme activities, involved in C, N, P and S cycling of soils, were measured (mg product released per kg soil per h). The activities of b-glucosidase, b-glucosaminidase, alkaline phosphatase, and arylsulfatase were significantly (P<0.05) increased in soils under cotton rotated with sorghum or wheat, and due to conservation tillage in comparison to continuous cotton under conventional tillage. Principal component analysis showed FAME profiles of these soils separated distinctly along PC1 (20 %) and PC2 (13 %) due to their differences in soil texture and management. No significant differences were detected in FAME profiles due to management practices for the same soils in this sampling period. Enzyme activities provide early indications of the benefits in microbial populations and activities and soil organic matter under crop rotations and conservation tillage in comparison to the typical practices in semiarid regions of continuous cotton and conventional tillage.

  7. Adaptive deep brain stimulation in advanced Parkinson disease.

    PubMed

    Little, Simon; Pogosyan, Alex; Neal, Spencer; Zavala, Baltazar; Zrinzo, Ludvic; Hariz, Marwan; Foltynie, Thomas; Limousin, Patricia; Ashkan, Keyoumars; FitzGerald, James; Green, Alexander L; Aziz, Tipu Z; Brown, Peter

    2013-09-01

    Brain-computer interfaces (BCIs) could potentially be used to interact with pathological brain signals to intervene and ameliorate their effects in disease states. Here, we provide proof-of-principle of this approach by using a BCI to interpret pathological brain activity in patients with advanced Parkinson disease (PD) and to use this feedback to control when therapeutic deep brain stimulation (DBS) is delivered. Our goal was to demonstrate that by personalizing and optimizing stimulation in real time, we could improve on both the efficacy and efficiency of conventional continuous DBS. We tested BCI-controlled adaptive DBS (aDBS) of the subthalamic nucleus in 8 PD patients. Feedback was provided by processing of the local field potentials recorded directly from the stimulation electrodes. The results were compared to no stimulation, conventional continuous stimulation (cDBS), and random intermittent stimulation. Both unblinded and blinded clinical assessments of motor effect were performed using the Unified Parkinson's Disease Rating Scale. Motor scores improved by 66% (unblinded) and 50% (blinded) during aDBS, which were 29% (p = 0.03) and 27% (p = 0.005) better than cDBS, respectively. These improvements were achieved with a 56% reduction in stimulation time compared to cDBS, and a corresponding reduction in energy requirements (p < 0.001). aDBS was also more effective than no stimulation and random intermittent stimulation. BCI-controlled DBS is tractable and can be more efficient and efficacious than conventional continuous neuromodulation for PD. Copyright © 2013 American Neurological Association.

  8. Chapter 4: The Cretaceous-Lower Tertiary Composite Total Petroleum System, Wind River Basin, Wyoming

    USGS Publications Warehouse

    Johnson, R.C.; Finn, Thomas M.; Kirschbaum, Mark A.; Roberts, Stephen B.; Roberts, Laura N.R.; Cook, Troy; Taylor, David J.

    2007-01-01

    The Cretaceous-Lower Tertiary Composite Total Petroleum System (TPS) of the Wind River Basin Province includes all strata from the base of the Lower Cretaceous Cloverly Formation to the base of the Waltman Shale Member of the Paleocene age Fort Union Formation and, where the Waltman is absent, includes strata as young as the Eocene Wind River Formation. Locally, Cretaceous-sourced gas migrated into strata as old as the Mississippian Madison Limestone, and in these areas the TPS extends stratigraphically downward to include these reservoirs. The extensive vertical migration of gases in highly fractured areas of the Wind River Basin led to the commingling of gases from several Upper Cretaceous and lower Tertiary sources, thus only two petroleum systems are recognized in these rocks, the Cretaceous-Lower Tertiary Composite TPS, the subject of this report, and the Waltman Shale TPS described by Roberts and others (Chapter 5, this CD-ROM). The Cretaceous-lower Tertiary Composite TPS was subdivided into (1) seven continuous gas assessment units (AU): (a) Frontier-Muddy Continuous Gas AU, (b) Cody Sandstone Continuous Gas AU, (c) Mesaverde--Meeteetse Sandstone Gas AU, (d) Lance-Fort Union Sandstone Gas AU, (e) Mesaverde Coalbed Gas AU, (f) Meeteetse Coalbed Gas AU, and (g) Fort Union Coalbed Gas AU; (2) one continuous oil assessement unit--- Cody Fractured Shale Continuous Oil AU; and (3) one conventional assessment Unit--- Cretaceous-Tertiary Conventional Oil and Gas AU. Estimates of undiscovered resources having the potential for additions to reserves were made for all but the Cody Fractured Shale Continuous Oil AU, which is considered hypothetical and was not quantitively assessed. The mean estimate of the total oil is 41.99 million barrels, mean estimate of gas is 2.39 trillion cubic feet, and mean estimate of natural gas liquids is 20.55 million barrels. For gas, 480.66 billion cubic feet (BCFG) is estimated for the Frontier-Muddy Continuous Gas AU, 115.34 BCFG for the Cody Sandstone Continuous Gas AU, 383.16 BCFG for the Mesaverde-Meeteetse Sandstone Continuous Gas AU, 711.30 BCFG for the Lance-Fort Union Sandstone Gas AU, 107.18 BCFG for the Mesaverde Coalbed Gas AU, 21.29 BCFG for the Meeteetse Coalbed Gas AU, and 118.08 BCFG for the Fort Union Coalbed Gas AU. All the undiscovered oil and 98.94 BCFG of undiscovered gas is in the Cretaceous-Tertiary Conventional Oil and Gas AU.

  9. Chapter 2. Assessment of undiscovered conventional oil and gas resources--Upper Jurassic-Lower Cretaceous Cotton Valley group, Jurassic Smackover interior salt basins total petroleum system, in the East Texas basin and Louisiana-Mississippi salt basins provinces.

    USGS Publications Warehouse

    Dyman, T.S.; Condon, S.M.

    2006-01-01

    The Jurassic Smackover Interior Salt Basins Total Petroleum System is defined for this assessment to include (1) Upper Jurassic Smackover Formation carbonates and calcareous shales and (2) Upper Jurassic and Lower Cretaceous Cotton Valley Group organic-rich shales. The Jurassic Smackover Interior Salt Basins Total Petroleum System includes four conventional Cotton Valley assessment units: Cotton Valley Blanket Sandstone Gas (AU 50490201), Cotton Valley Massive Sandstone Gas (AU 50490202), Cotton Valley Updip Oil and Gas (AU 50490203), and Cotton Valley Hypothetical Updip Oil (AU 50490204). Together, these four assessment units are estimated to contain a mean undiscovered conventional resource of 29.81 million barrels of oil, 605.03 billion cubic feet of gas, and 19.00 million barrels of natural gas liquids. The Cotton Valley Group represents the first major influx of clastic sediment into the ancestral Gulf of Mexico. Major depocenters were located in south-central Mississippi, along the Louisiana-Mississippi border, and in northeast Texas. Reservoir properties and production characteristics were used to identify two Cotton Valley Group sandstone trends across northern Louisiana and east Texas: a high-permeability blanket-sandstone trend and a downdip, low-permeability massive-sandstone trend. Pressure gradients throughout most of both trends are normal, which is characteristic of conventional rather than continuous basin-center gas accumulations. Indications that accumulations in this trend are conventional rather than continuous include (1) gas-water contacts in at least seven fields across the blanket-sandstone trend, (2) relatively high reservoir permeabilities, and (3) high gas-production rates without fracture stimulation. Permeability is sufficiently low in the massive-sandstone trend that gas-water transition zones are vertically extensive and gas-water contacts are poorly defined. The interpreted presence of gas-water contacts within the Cotton Valley massive-sandstone trend, however, suggests that accumulations in this trend are also conventional.

  10. Bubble vs conventional continuous positive airway pressure for prevention of extubation failure in preterm very low birth weight infants: a pilot study.

    PubMed

    Yadav, Sucheta; Thukral, Anu; Sankar, M Jeeva; Sreenivas, V; Deorari, Ashok K; Paul, Vinod K; Agarwal, Ramesh

    2012-09-01

    To compare the efficacy of bubble and conventional nasal continuous positive airway pressure (CPAP) in preventing extubation failure (EF) in preterm infants. Infants of gestation ≤32 wk and birth weight <1500 g, ready for initial extubation within first wk of life were randomly allocated to either bubble (n = 16) or conventional (n = 16) CPAP. A standardized protocol was used for extubation. Bubble CPAP was delivered by Fischer and Paykel equipment using short binasal prongs and conventional CPAP was delivered by a ventilator using Argyle short binasal prongs. CPAP was initiated at a pressure of 4-6 cm of H(2)O and FiO(2) of 0.4-0.5 and adjusted to maintain normal saturation (90-93%) and comfortable breathing. Primary outcome was EF, defined as need for mechanical ventilation within 72 h of extubation. Baseline characteristics including birth weight (g; 1027 ± 243 vs. 1018 ± 227; p = 0.83), gestation (wk; 28.7 ± 1.8 vs. 28.4 ± 1.6; p = 0.30), infants <28 wk gestation (6 vs. 7, p = 0.72) were comparable between the two groups. Respiratory distress syndrome was the indication for ventilation in 13 (81%) and 14 (87%) infants on bubble CPAP and conventional CPAP groups respectively. (p = 0.99). There was no difference in the EF rates between the bubble (n = 4) and conventional CPAP (n = 9) groups. (RR 0.49; 95% CI 0.20-1.2; p = 0.14). Median time to extubation failure was also comparable between the two groups (h; median [range]: 29 [14-49] vs. 17 [7-28]; p = 0.35). The possibility that bubble CPAP may be associated with reduced EF as suggested in this pilot study requires further investigation in an adequately powered multicentric study.

  11. Using Field Measurements to Assess Aging of Self-Cleaning High-Reflectance Paint

    NASA Astrophysics Data System (ADS)

    Takebayashi, Hideki; Tanabe, Junichiro; Aoyama, Taizo; Sonoda, Takeshi; Nakanishi, Yasushi

    2017-08-01

    Continuous field measurements were used to evaluate the aging of solar reflectance on self-cleaning coatings for roofs in comparison with conventional coatings that have no self-cleaning function. Solar reflectance on self-cleaning coatings decreases by about 6 % per year with annual variations, due to the adhesion of dirt. On the other hand, solar reflectance on conventional coatings greatly decreases, by approximately 18 % within four months of the coating's application, due to the adhesion of dirt. Then, it gradually recovers at a rate of about 4 % per year, with annual variations, due to degradation of the coating. It is due to degradation of the conventional coating that the difference of solar reflectance between the self-cleaning coating and the conventional coating becomes almost zero in two years. Both the adhesion of dirt and coating degradation by chalking affect the temporal change of solar reflectance with annual variation.

  12. Conventional armed forces in Europe: Technology scenario development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Houser, G.M.

    1990-07-01

    In January 1986, the Soviet Union's Mikhail Gorbachev proposed elimination of all nuclear weapons by the year 2000. In April of that year, Mr. Gorbachev proposed substantial reductions of conventional weapons in Europe, from the Atlantic Ocean to the Ural Mountains, including reductions in operational-tactical nuclear weapons. In May 1986, the North Atlantic Treaty Organization (NATO) responded with the Brussels Declaration on Conventional Arms Control,'' which indicated readiness to open East/West discussions on establishing a mandate for negotiating conventional arms control throughout Europe. The Group of 23,'' which met in Vienna beginning in February 1987, concluded the meeting in Januarymore » 1989 with a mandate for the Conventional Armed Forced in Europe (CFE) negotiations. On 6 March 1989, CFE talks began, and these talks have continued through six rounds (as of April 1990). Although US President George Bush, on 30 May 1989, called for agreement within six months to a year, and the Malta meeting of December 1989 called for completion of a CFE agreement by the end of 1990, much remains to be negotiated. This report provides three types of information. First, treaty provisions brought to the table by both sides are compared. Second, on the basis of these provisions, problem areas for each of the provision elements are postulated and possible scenarios for resolving these problem areas are developed. Third, the scenarios are used as requirements for tasks assigned program elements for possible US implementation of a CFE treaty. As progress is achieved during the negotiations, this report could be updated, as necessary, in each of the areas to provide a continuing systematic basis for program implementation and technology development. 8 refs.« less

  13. Geographic information system (GIS)-based maps of Appalachian basin oil and gas fields: Chapter C.2 in Coal and petroleum resources in the Appalachian basin: distribution, geologic framework, and geochemical character

    USGS Publications Warehouse

    Ryder, Robert T.; Kinney, Scott A.; Suitt, Stephen E.; Merrill, Matthew D.; Trippi, Michael H.; Ruppert, Leslie F.; Ryder, Robert T.

    2014-01-01

    In 2006 and 2007, the greenline Appalachian basin field maps were digitized under the supervision of Scott Kinney and converted to geographic information system (GIS) files for chapter I.1 (this volume). By converting these oil and gas field maps to a digital format and maintaining the field names where noted, they are now available for a variety of oil and gas and possibly carbon-dioxide sequestration projects. Having historical names assigned to known digitized conventional fields provides a convenient classification scheme into which cumulative production and ultimate field-size databases can be organized. Moreover, as exploratory and development drilling expands across the basin, many previously named fields that were originally treated as conventional fields have evolved into large, commonly unnamed continuous-type accumulations. These new digital maps will facilitate a comparison between EUR values from recently drilled, unnamed parts of continuous accumulations and EUR values from named fields discovered early during the exploration cycle of continuous accumulations.

  14. 40 CFR 445.12 - Effluent limitations attainable by the application of the best conventional pollutant control...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LANDFILLS POINT SOURCE CATEGORY RCRA Subtitle C Hazardous Waste Landfill § 445.12 Effluent limitations attainable by the...

  15. 40 CFR 445.22 - Effluent limitations attainable by the application of the best conventional pollutant control...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LANDFILLS POINT SOURCE CATEGORY RCRA Subtitle D Non-Hazardous Waste Landfill § 445.22 Effluent limitations attainable by...

  16. Investigation of negative moment reinforcing in bridge decks.

    DOT National Transportation Integrated Search

    2015-09-01

    Multi-span pre-tensioned pre-stressed concrete beam (PPCB) bridges made continuous usually experience a negative live load : moment region over the intermediate supports. Conventional thinking dictates that sufficient reinforcement must be provided i...

  17. 26 CFR 521.102 - Applicable provisions of the Internal Revenue Code.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS DENMARK General Income Tax Taxation of Nonresident Aliens Who... income and shall be exempt from taxation under this chapter: (7) Income exempt under treaty. Income of...

  18. 26 CFR 521.102 - Applicable provisions of the Internal Revenue Code.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS DENMARK General Income Tax Taxation of Nonresident Aliens Who... income and shall be exempt from taxation under this chapter: (7) Income exempt under treaty. Income of...

  19. A continuous mixing model for pdf simulations and its applications to combusting shear flows

    NASA Technical Reports Server (NTRS)

    Hsu, A. T.; Chen, J.-Y.

    1991-01-01

    The problem of time discontinuity (or jump condition) in the coalescence/dispersion (C/D) mixing model is addressed in this work. A C/D mixing model continuous in time is introduced. With the continuous mixing model, the process of chemical reaction can be fully coupled with mixing. In the case of homogeneous turbulence decay, the new model predicts a pdf very close to a Gaussian distribution, with finite higher moments also close to that of a Gaussian distribution. Results from the continuous mixing model are compared with both experimental data and numerical results from conventional C/D models.

  20. Novel method to sample very high power CO2 lasers: II Continuing Studies

    NASA Astrophysics Data System (ADS)

    Eric, John; Seibert, Daniel B., II; Green, Lawrence I.

    2005-04-01

    For the past 28 years, the Laser Hardened Materials Evaluation Laboratory (LHMEL) at the Wright-Patterson Air Force Base, OH, has worked with CO2 lasers capable of producing continuous energy up to 150 kW. These lasers are used in a number of advanced materials processing applications that require accurate spatial energy measurements of the laser. Conventional non-electronic methods are not satisfactory for determining the spatial energy profile. This paper describes continuing efforts in qualifying the new method in which a continuous, real-time electronic spatial energy profile can be obtained for very high power, (VHP) CO2 lasers.

  1. Gas absorption/desorption temperature-differential engine

    NASA Technical Reports Server (NTRS)

    Miller, C. G.

    1981-01-01

    Continuously operating compressor system converts 90 percent of gas-turbine plant energy to electricity. Conventional plants work in batch mode, operating at 40 percent efficiency. Compressor uses metal hydride matrix on outside of rotating drum to generate working gas, hydrogen. Rolling valve seals allow continuous work. During operation, gas is absorbed, releasing heat, and desorbed with heat gain. System conserves nuclear and fossil fuels, reducing powerplant capital and operating costs.

  2. Indirect comparisons of efficacy and weekly factor consumption during continuous prophylaxis with recombinant factor VIII Fc fusion protein and conventional recombinant factor VIII products.

    PubMed

    Iorio, A; Krishnan, S; Myrén, K J; Lethagen, S; McCormick, N; Yermakov, S; Karner, P

    2017-05-01

    Recombinant factor VIII (rFVIII) products with extended half-lives have the potential to improve adherence and outcomes in haemophilia beyond the results obtained with conventional rFVIII products. In the absence of head-to-head comparisons, annualized bleed rates (ABRs) and weekly factor consumption with rFVIII Fc fusion protein (rFVIIIFc) and conventional rFVIII products were indirectly compared using studies of continuous prophylaxis. A systematic literature review was conducted to identify studies of rFVIII products for comparison with rFVIIIFc in the continuous prophylactic treatment of previously treated adolescents and adults with moderate and severe haemophilia A. Mean ABRs were compared between rFVIIIFc and individual rFVIII studies and between rFVIIIFc and a pooled measure for rFVIII estimated by meta-analysis. Comparisons of factor consumption were based on mean or median weekly factor consumption. Results from seven studies of conventional rFVIII products (injections 2-4 times week -1 ) were compared with rFVIIIFc (injections 1.4-2.4 times week -1 ). The pooled mean ABR for rFVIII products was significantly higher compared with rFVIIIFc (difference = 2.0; P = 0.007). Compared with most rFVIII studies, the reported weekly factor consumption was lower with rFVIIIFc [mean differences = 15.5-21.8 IU kg -1 week -1 (17-26%); median differences = 12.7-29.8 IU kg -1 week -1 (16-37%)]. In one comparison, mean weekly factor consumption with rFVIII was significantly lower but mean ABR was significantly higher than rFVIIIFc. Prophylaxis with rFVIIIFc may be associated with improved bleeding rates and lower weekly factor consumption than more frequently injected rFVIII products. Relative to rFVIII products with similar bleeding rates, results indicate that rFVIIIFc is associated with reduced weekly factor consumption while requiring fewer prescribed injections. © 2017 John Wiley & Sons Ltd.

  3. Real life cost and quality of life associated with continuous intraduodenal levodopa infusion compared with oral treatment in Parkinson patients.

    PubMed

    Lundqvist, Christofer; Beiske, Antonie Giæver; Reiertsen, Ola; Kristiansen, Ivar Sønbø

    2014-12-01

    Advanced-stage Parkinson's disease (PD) strongly affects quality of life (QoL). Continuous intraduodenal administration of levodopa (IDL) is efficacious, but entails high costs. This study aims to estimate these costs in routine care. 10 patients with advanced-PD who switched from oral medication to IDL were assessed at baseline, and subsequently at 3, 6, 9 and 12 months follow-up. We used the Unified PD Rating Scale (UPDRS) for function and 15D for Quality of Life (QoL). Costs were assessed using quarterly structured patient questionnaires and hospital registries. Costs per quality adjusted life year (QALY) were estimated for conventional treatment prior to switch and for 1-year treatment with IDL. Probabilistic sensitivity analysis was based on bootstrapping. IDL significantly improved functional scores and was safe to use. One-year conventional oral treatment entailed 0.63 QALY while IDL entailed 0.68 (p > 0.05). The estimated total 1-year treatment cost was NOK419,160 on conventional treatment and NOK890,920 on IDL, representing a cost of NOK9.2 million (€1.18 mill) per additional QALY. The incremental cost per unit UPDRS improvement was NOK25,000 (€3,250). Medication was the dominant cost during IDL (45% of total costs), it represented only 6.4% of the total for conventional treatment. IDL improves function but is not cost effective using recommended thresholds for cost/QALY in Norway.

  4. Type IIB thyroplasty for phonic tics in a pediatric patient with autism spectrum disorder: a case report.

    PubMed

    Ahmed, Mostafa M; Heckman, W Wesley; Dailey, Seth H

    2013-03-01

    Autism spectrum disorders (ASDs) are commonly associated with Tourette syndrome (TS). TS is classically associated with tic production. A tic is defined as sudden, brief, involuntary production of movement (motor tics) or sound (phonic tics). Case report. We present a case report of a 14-year-old boy with ASD and vocal tics. Vocal tic frequency was nearly 2000 per day and 90 dB in volume. He presented to our laryngology clinic after multiple failed attempts of pharmacologic management of vocal fold botulinum toxin injection. After evaluation in our clinic, we recommended a lateralization (type IIB) thyroplasty. An autologous cartilage graft from the superior thyroid ala was used and held in place with a bioresorbable mesh. Using 4-0 prolene sutures, the mesh was secured in place. The operation was well tolerated with minimal signs of aspiration, and he was discharged to his home within 48 hours. Six months postoperatively, there was 90% reduction in tic frequency and 50% reduction in intensity. Additionally, he has shown improved ability to converse with his peers, participate in school activities, and even has improved nutritional status. Alteration of laryngeal geometry could serve as an effective site of intervention for intractable phonic tics. Reduction of phonic tic frequency and intensity may also stimulate language development in patients ASD. We also demonstrate additional use of bioresorbable plates in pediatric laryngeal framework surgery. Additional neurophysiologic studies are needed to explore the mechanism by which midline lateralization thyroplasty influences phonic tic generation. Copyright © 2013 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  5. Accuracy of continuous noninvasive hemoglobin monitoring for the prediction of blood transfusions in trauma patients.

    PubMed

    Galvagno, Samuel M; Hu, Peter; Yang, Shiming; Gao, Cheng; Hanna, David; Shackelford, Stacy; Mackenzie, Colin

    2015-12-01

    Early detection of hemorrhagic shock is required to facilitate prompt coordination of blood component therapy delivery to the bedside and to expedite performance of lifesaving interventions. Standard physical findings and vital signs are difficult to measure during the acute resuscitation stage, and these measures are often inaccurate until patients deteriorate to a state of decompensated shock. The aim of this study is to examine a severely injured trauma patient population to determine whether a noninvasive SpHb monitor can predict the need for urgent blood transfusion (universal donor or additional urgent blood transfusion) during the first 12 h of trauma patient resuscitation. We hypothesize that trends in continuous SpHb, combined with easily derived patient-specific factors, can identify the immediate need for transfusion in trauma patients. Subjects were enrolled if directly admitted to the trauma center, >17 years of age, and with a shock index (heart rate/systolic blood pressure) >0.62. Upon admission, a Masimo Radical-7 co-oximeter sensor (Masimo Corporation, Irvine, CA) was applied, providing measurement of continuous non-invasive hemoglobin (SpHb) levels. Blood was drawn and hemoglobin concentration analyzed and conventional pulse oximetry photopletysmograph signals were continuously recorded. Demographic information and both prehospital and admission vital signs were collected. The primary outcome was transfusion of at least one unit of packed red blood cells within 24 h of admission. Eight regression models (C1-C8) were evaluated for the prediction of blood use by comparing area under receiver operating curve (AUROC) at different time intervals after admission. 711 subjects had continuous vital signs waveforms available, to include heart rate (HR), SpHb and SpO2 trends. When SpHb was monitored for 15 min, SpHb did not increase AUROC for prediction of transfusion. The highest ROC was recorded for model C8 (age, sex, prehospital shock index, admission HR, SpHb and SpO2) for the prediction of blood products within the first 3 h of admission. When data from 15 min of continuous monitoring were analyzed, significant improvement in AUROC occurred as more variables were added to the model; however, the addition of SpHb to any of the models did not improve AUROC significantly for prediction of blood use within the first 3 h of admission in comparison to analysis of conventional oximetry features. The results demonstrate that SpHb monitoring, accompanied by continuous vital signs data and adjusted for age and sex, has good accuracy for the prediction of need for transfusion; however, as an independent variable, SpHb did not enhance predictive models in comparison to use of features extracted from conventional pulse oximetry. Nor was shock index better than conventional oximetry at discriminating hemorrhaging and prediction of casualties receiving blood. In this population of trauma patients, noninvasive SpHb monitoring, including both trends and absolute values, did not enhance the ability to predict the need for blood transfusion.

  6. A Mobile Device App to Reduce Time to Drug Delivery and Medication Errors During Simulated Pediatric Cardiopulmonary Resuscitation: A Randomized Controlled Trial.

    PubMed

    Siebert, Johan N; Ehrler, Frederic; Combescure, Christophe; Lacroix, Laurence; Haddad, Kevin; Sanchez, Oliver; Gervaix, Alain; Lovis, Christian; Manzano, Sergio

    2017-02-01

    During pediatric cardiopulmonary resuscitation (CPR), vasoactive drug preparation for continuous infusion is both complex and time-consuming, placing children at higher risk than adults for medication errors. Following an evidence-based ergonomic-driven approach, we developed a mobile device app called Pediatric Accurate Medication in Emergency Situations (PedAMINES), intended to guide caregivers step-by-step from preparation to delivery of drugs requiring continuous infusion. The aim of our study was to determine whether the use of PedAMINES reduces drug preparation time (TDP) and time to delivery (TDD; primary outcome), as well as medication errors (secondary outcomes) when compared with conventional preparation methods. The study was a randomized controlled crossover trial with 2 parallel groups comparing PedAMINES with a conventional and internationally used drugs infusion rate table in the preparation of continuous drug infusion. We used a simulation-based pediatric CPR cardiac arrest scenario with a high-fidelity manikin in the shock room of a tertiary care pediatric emergency department. After epinephrine-induced return of spontaneous circulation, pediatric emergency nurses were first asked to prepare a continuous infusion of dopamine, using either PedAMINES (intervention group) or the infusion table (control group), and second, a continuous infusion of norepinephrine by crossing the procedure. The primary outcome was the elapsed time in seconds, in each allocation group, from the oral prescription by the physician to TDD by the nurse. TDD included TDP. The secondary outcome was the medication dosage error rate during the sequence from drug preparation to drug injection. A total of 20 nurses were randomized into 2 groups. During the first study period, mean TDP while using PedAMINES and conventional preparation methods was 128.1 s (95% CI 102-154) and 308.1 s (95% CI 216-400), respectively (180 s reduction, P=.002). Mean TDD was 214 s (95% CI 171-256) and 391 s (95% CI 298-483), respectively (177.3 s reduction, P=.002). Medication errors were reduced from 70% to 0% (P<.001) by using PedAMINES when compared with conventional methods. In this simulation-based study, PedAMINES dramatically reduced TDP, to delivery and the rate of medication errors. ©Johan N Siebert, Frederic Ehrler, Christophe Combescure, Laurence Lacroix, Kevin Haddad, Oliver Sanchez, Alain Gervaix, Christian Lovis, Sergio Manzano. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 01.02.2017.

  7. Schedule-Dependent Antiangiogenic and Cytotoxic Effects of Chemotherapy on Vascular Endothelial and Retinoblastoma Cells.

    PubMed

    Winter, Ursula; Mena, Hebe A; Negrotto, Soledad; Arana, Eloisa; Pascual-Pasto, Guillem; Laurent, Viviana; Suñol, Mariona; Chantada, Guillermo L; Carcaboso, Angel M; Schaiquevich, Paula

    2016-01-01

    Current treatment of retinoblastoma involves using the maximum dose of chemotherapy that induces tumor control and is tolerated by patients. The impact of dose and schedule on the cytotoxicity of chemotherapy has not been studied. Our aim was to gain insight into the cytotoxic and antiangiogenic effect of the treatment scheme of chemotherapy used in retinoblastoma by means of different in vitro models and to evaluate potential effects on multi-drug resistance proteins. Two commercial and two patient-derived retinoblastoma cell types and two human vascular endothelial cell types were exposed to increasing concentrations of melphalan or topotecan in a conventional (single exposure) or metronomic (7-day continuous exposure) treatment scheme. The concentration of chemotherapy causing a 50% decrease in cell proliferation (IC50) was determined by MTT and induction of apoptosis was evaluated by flow cytometry. Expression of ABCB1, ABCG2 and ABCC1 after conventional or metronomic treatments was assessed by RT-qPCR. We also evaluated the in vivo response to conventional (0.6 mg/kg once a week for 2 weeks) and metronomic (5 days a week for 2 weeks) topotecan in a retinoblastoma xenograft model. Melphalan and topotecan were cytotoxic to both retinoblastoma and endothelial cells after conventional and metronomic treatments. A significant decrease in the IC50 (median, 13-fold; range: 3-23) was observed following metronomic chemotherapy treatment in retinoblastoma and endothelial cell types compared to conventional treatment (p<0.05). Metronomic topotecan or melphalan significantly inhibited in vitro tube formation in HUVEC and EPC compared to vehicle-treated cells (p<0.05). Both treatment schemes induced apoptosis and/or necrosis in all cell models. No significant difference was observed in the expression of ABCB1, ABCC1 or ABCG2 when comparing cells treated with melphalan or topotecan between treatment schedules at the IC50 or with control cells (p>0.05). In mice, continuous topotecan lead to significantly lower tumor volumes compared to conventional treatment after 14 days of treatment (p<0.05). Continuous exposure to melphalan or topotecan increased the chemosensitivity of retinoblastoma and endothelial cells to both chemotherapy agents with lower IC50 values compared to short-term treatment. These findings were validated in an in vivo model. None of the dosing modalities induced multidrug resistance mechanisms while apoptosis was the mechanism of cell death after both treatment schedules. Metronomic chemotherapy may be a valid option for retinoblastoma treatment allowing reductions of the daily dose.

  8. 50 CFR 23.32 - How do I apply for a U.S. CITES document?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD... species is also regulated under another part of this subchapter (such as endangered or threatened species...

  9. 50 CFR 23.32 - How do I apply for a U.S. CITES document?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD... species is also regulated under another part of this subchapter (such as endangered or threatened species...

  10. 50 CFR 23.32 - How do I apply for a U.S. CITES document?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD... species is also regulated under another part of this subchapter (such as endangered or threatened species...

  11. 26 CFR 521.115 - Credit against United States tax liability for Danish tax.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS DENMARK General Income Tax Taxation of Nonresident Aliens Who... liability for Danish tax. For the purpose of avoidance of double taxation, Article XV provides that, on the...

  12. 33 CFR 155.380 - Oily water separating equipment and bilge alarm approval standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION OIL OR HAZARDOUS MATERIAL POLLUTION... § 155.380(b): A copy of Annex I to the International Convention for the Prevention of Pollution from...

  13. 26 CFR 521.115 - Credit against United States tax liability for Danish tax.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS DENMARK General Income Tax Taxation of Nonresident Aliens Who... liability for Danish tax. For the purpose of avoidance of double taxation, Article XV provides that, on the...

  14. Avoiding Focus Shifts in Surgical Telementoring Using an Augmented Reality Transparent Display.

    PubMed

    Andersen, Daniel; Popescu, Voicu; Cabrera, Maria Eugenia; Shanghavi, Aditya; Gomez, Gerardo; Marley, Sherri; Mullis, Brian; Wachs, Juan

    2016-01-01

    Conventional surgical telementoring systems require the trainee to shift focus away from the operating field to a nearby monitor to receive mentor guidance. This paper presents the next generation of telementoring systems. Our system, STAR (System for Telementoring with Augmented Reality) avoids focus shifts by placing mentor annotations directly into the trainee's field of view using augmented reality transparent display technology. This prototype was tested with pre-medical and medical students. Experiments were conducted where participants were asked to identify precise operating field locations communicated to them using either STAR or a conventional telementoring system. STAR was shown to improve accuracy and to reduce focus shifts. The initial STAR prototype only provides an approximate transparent display effect, without visual continuity between the display and the surrounding area. The current version of our transparent display provides visual continuity by showing the geometry and color of the operating field from the trainee's viewpoint.

  15. Preliminary Design and Evaluation of an Airfoil with Continuous Trailing-Edge Flap

    NASA Technical Reports Server (NTRS)

    Shen, Jinwei; Thornburgh, Robert P.; Kreshock, Andrew R.; Wilbur, Matthew L.; Liu, Yi

    2012-01-01

    This paper presents the preliminary design and evaluation of an airfoil with active continuous trailing-edge flap (CTEF) as a potential rotorcraft active control device. The development of structural cross-section models of a continuous trailing-edge flap airfoil is described. The CTEF deformations with MFC actuation are predicted by NASTRAN and UM/VABS analyses. Good agreement is shown between the predictions from the two analyses. Approximately two degrees of CTEF deflection, defined as the rotation angle of the trailing edge, is achieved with the baseline MFC-PZT bender. The 2D aerodynamic characteristics of the continuous trailing-edge flap are evaluated using a CFD analysis. The aerodynamic efficiency of a continuous trailing-edge flap is compared to that of a conventional discrete trailing-edge flap (DTEF). It is found that the aerodynamic characteristics of a CTEF are equivalent to those of a conventional DTEF with the same deflection angle but with a smaller flap chord. A fluid structure interaction procedure is implemented to predict the deflection of the continuous trailingedge flap under aerodynamic pressure. The reductions in CTEF deflection are overall small when aerodynamic pressure is applied: 2.7% reduction is shown with a CTEF deflection angle of two degrees and at angle of attack of six degrees. In addition, newly developed MFC-PMN actuator is found to be a good supplement to MFC-PZT when applied as the bender outside layers. A mixed MFC-PZT and MFC-PMN bender generates 3% more CTEF deformation than an MFC-PZT only bender and 5% more than an MFC-PMN only bender under aerodynamic loads.

  16. Comparison of the financial performance of Islamic and conventional bank in Malaysia during and after economic crisis

    NASA Astrophysics Data System (ADS)

    Kadir, Norhidayah A.; Jaffar, Aidatullaini; Abdullah, Nur Lina; Harun, Nurzalina

    2013-09-01

    This paper is a continuation of our former work. In this paper, we compare the financial performance of the two banking systems that exist in Malaysia over two periods of time, during economic crisis (1997-1999) and after economic crisis (2001-2003). In order to see the conventional as well as Islamic bank's performance over these two periods of time, the study uses 10 financial ratios which are broadly categorized into 4 groups: (a) profitability ratios; (b) liquidity ratios; (c) risk and solvency ratios; and (d) efficiency ratios. Next, the study used T-test in determining the significance of the differential performance of the two banks over two periods of time. By using inter-bank comparison, the study found that, conventional bank has better performance, efficient, more profitable and has greater risk as compared to Islamic bank. However, in terms of utilizing asset, Islamic bank is better than conventional bank. As an overall, conventional bank is better in much aspect due to the longer history and experience in the industry than Islamic bank that start their operation in 1983.

  17. Continuous Manufacturing of Recombinant Therapeutic Proteins: Upstream and Downstream Technologies.

    PubMed

    Patil, Rohan; Walther, Jason

    2017-03-07

    Continuous biomanufacturing of recombinant therapeutic proteins offers several potential advantages over conventional batch processing, including reduced cost of goods, more flexible and responsive manufacturing facilities, and improved and consistent product quality. Although continuous approaches to various upstream and downstream unit operations have been considered and studied for decades, in recent years interest and application have accelerated. Researchers have achieved increasingly higher levels of process intensification, and have also begun to integrate different continuous unit operations into larger, holistically continuous processes. This review first discusses approaches for continuous cell culture, with a focus on perfusion-enabling cell separation technologies including gravitational, centrifugal, and acoustic settling, as well as filtration-based techniques. We follow with a review of various continuous downstream unit operations, covering categories such as clarification, chromatography, formulation, and viral inactivation and filtration. The review ends by summarizing case studies of integrated and continuous processing as reported in the literature.

  18. Wind Tunnel Wall Interference Assessment and Correction, 1983

    NASA Technical Reports Server (NTRS)

    Newman, P. A. (Editor); Barnwell, R. W. (Editor)

    1984-01-01

    Technical information focused upon emerging wall interference assessment/correction (WIAC) techniques applicable to transonic wind tunnels with conventional and passively or partially adapted walls is given. The possibility of improving the assessment and correction of data taken in conventional transonic wind tunnels by utilizing simultaneously obtained flow field data (generally taken near the walls) appears to offer a larger, nearer-term payoff than the fully adaptive wall concept. Development of WIAC procedures continues, and aspects related to validating the concept need to be addressed. Thus, the scope of wall interference topics discussed was somewhat limited.

  19. Modeling commodity salam contract between two parties for discrete and continuous time series

    NASA Astrophysics Data System (ADS)

    Hisham, Azie Farhani Badrol; Jaffar, Maheran Mohd

    2017-08-01

    In order for Islamic finance to remain competitive as the conventional, there needs a new development of Islamic compliance product such as Islamic derivative that can be used to manage the risk. However, under syariah principles and regulations, all financial instruments must not be conflicting with five syariah elements which are riba (interest paid), rishwah (corruption), gharar (uncertainty or unnecessary risk), maysir (speculation or gambling) and jahl (taking advantage of the counterparty's ignorance). This study has proposed a traditional Islamic contract namely salam that can be built as an Islamic derivative product. Although a lot of studies has been done on discussing and proposing the implementation of salam contract as the Islamic product however they are more into qualitative and law issues. Since there is lack of quantitative study of salam contract being developed, this study introduces mathematical models that can value the appropriate salam price for a commodity salam contract between two parties. In modeling the commodity salam contract, this study has modified the existing conventional derivative model and come out with some adjustments to comply with syariah rules and regulations. The cost of carry model has been chosen as the foundation to develop the commodity salam model between two parties for discrete and continuous time series. However, the conventional time value of money results from the concept of interest that is prohibited in Islam. Therefore, this study has adopted the idea of Islamic time value of money which is known as the positive time preference, in modeling the commodity salam contract between two parties for discrete and continuous time series.

  20. Update on new technologies in digital mammography

    PubMed Central

    Patterson, Stephanie K; Roubidoux, Marilyn A

    2014-01-01

    Despite controversy regarding mammography’s efficacy, it continues to be the most commonly used breast cancer-screening modality. With the development of digital mammography, some improved benefit has been shown in women with dense breast tissue. However, the density of breast tissue continues to limit the sensitivity of conventional mammography. We discuss the development of some derivative digital technologies, primarily digital breast tomosynthesis, and their strengths, weaknesses, and potential patient impact. PMID:25152634

  1. A Realistic Framework for Delay-Tolerant Network Routing in Open Terrains with Continuous Churn

    NASA Astrophysics Data System (ADS)

    Mahendran, Veeramani; Anirudh, Sivaraman K.; Murthy, C. Siva Ram

    The conventional analysis of Delay-Tolerant Network (DTN) routing assumes that the terrain over which nodes move is closed implying that when the nodes hit a boundary, they either wrap around or get reflected. In this work, we study the effect of relaxing this closed terrain assumption on the routing performance, where a continuous stream of nodes enter the terrain and get absorbed upon hitting the boundary.

  2. NEW TECHNIQUE FOR OBESITY SURGERY: INTERNAL GASTRIC PLICATION TECHNIQUE USING INTRAGASTRIC SINGLE-PORT (IGS-IGP) IN EXPERIMENTAL MODEL.

    PubMed

    Müller, Verena; Fikatas, Panagiotis; Gül, Safak; Noesser, Maximilian; Fuehrer, Kirs Ten; Sauer, Igor; Pratschke, Johann; Zorron, Ricardo

    2017-01-01

    Bariatric surgery is currently the most effective method to ameliorate co-morbidities as consequence of morbidly obese patients with BMI over 35 kg/m2. Endoscopic techniques have been developed to treat patients with mild obesity and ameliorate comorbidities, but endoscopic skills are needed, beside the costs of the devices. To report a new technique for internal gastric plication using an intragastric single port device in an experimental swine model. Twenty experiments using fresh pig cadaver stomachs in a laparoscopic trainer were performed. The procedure was performed as follow in ten pigs: 1) volume measure; 2) insufflation of the stomach with CO2; 3) extroversion of the stomach through the simulator and installation of the single port device (Gelpoint Applied Mini) through a gastrotomy close to the pylorus; 4) performance of four intragastric handsewn 4-point sutures with Prolene 2-0, from the gastric fundus to the antrum; 5) after the performance, the residual volume was measured. Sleeve gastrectomy was also performed in further ten pigs and pre- and post-procedure gastric volume were measured. The internal gastric plication technique was performed successfully in the ten swine experiments. The mean procedure time was 27±4 min. It produced a reduction of gastric volume of a mean of 51%, and sleeve gastrectomy, a mean of 90% in this swine model. The internal gastric plication technique using an intragastric single port device required few skills to perform, had low operative time and achieved good reduction (51%) of gastric volume in an in vitro experimental model. A cirurgia bariátrica é atualmente o método mais efetivo para melhorar as co-morbidades decorrentes da obesidade mórbida com IMC acima de 35 kg/m2. Técnicas endoscópicas foram desenvolvidas para tratar pacientes com obesidade leve e melhorar as comorbidades, mas habilidades endoscópicas são necessárias, além dos custos. Relatar uma nova técnica para a plicatura gástrica interna utilizando um dispositivo intragástrico de portal único em modelo experimental de suínos. Foram realizados 20 experimentos utilizando estômagos de cadáver de porco fresco em um instrutor laparoscópico. O procedimento foi realizado da seguinte forma em dez porcos: 1) medida de volume; 2) insuflação do estômago com CO2; 3) extroversão do estômago através do simulador e instalação do dispositivo de uma única via (Gelpoint Applied Mini) através de uma gastrotomia próxima ao piloro; 4) realização de quatro suturas de quatro pontos intra-gástricas com Prolene 2-0, desde o fundo gástrico até o antro; 5) medição do volume residual. A gastrectomia vertical foi também realizada em mais dez suínos e o volume gástrico pré e pós-procedimento foi medido. A técnica de plicatura gástrica interna foi realizada com sucesso nos dez experimentos com suínos. O tempo médio do procedimento foi de 27±4 min. Produziu redução do volume gástrico em média de 51%, e a gastrectomia vertical em média de 90% neste modelo suíno. A técnica de plicatura gástrica interna, utilizando um dispositivo intragástrico de uma única via, exigiu poucas habilidades para ser realizada, teve baixo tempo operatório e obteve boa redução (51%) do volume gástrico em um modelo experimental in vitro.

  3. A comparative parametric study of a catalytic plate methane reformer coated with segmented and continuous layers of combustion catalyst for hydrogen production

    NASA Astrophysics Data System (ADS)

    Mundhwa, Mayur; Parmar, Rajesh D.; Thurgood, Christopher P.

    2017-03-01

    A parametric comparison study is carried out between segmented and conventional continuous layer configurations of the coated combustion-catalyst to investigate their influence on the performance of methane steam reforming (MSR) for hydrogen production in a catalytic plate reactor (CPR). MSR is simulated on one side of a thin plate over a continuous layer of nickel-alumina catalyst by implementing an experimentally validated surface microkinetic model. Required thermal energy for the MSR reaction is supplied by simulating catalytic methane combustion (CMC) on the opposite side of the plate over segmented and continuous layer of a platinum-alumina catalyst by implementing power law rate model. The simulation results of both coating configurations of the combustion-catalyst are compared using the following parameters: (1) co-flow and counter-flow modes between CMC and MSR, (2) gas hourly space velocity and (3) reforming-catalyst thickness. The study explains why CPR designed with the segmented combustion-catalyst and co-flow mode shows superior performance not only in terms of high hydrogen production but also in terms of minimizing the maximum reactor plate temperature and thermal hot-spots. The study shows that the segmented coating requires 7% to 8% less combustion-side feed flow and 70% less combustion-catalyst to produce the required flow of hydrogen (29.80 mol/h) on the reforming-side to feed a 1 kW fuel-cell compared to the conventional continuous coating of the combustion-catalyst.

  4. 40 CFR 408.23 - [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 30 2013-07-01 2012-07-01 true [Reserved] 408.23 Section 408.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY Conventional Blue Crab Processing...

  5. 40 CFR 408.21 - Specialized definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Specialized definitions. 408.21 Section 408.21 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY Conventional Blue Crab...

  6. 40 CFR 408.23 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 29 2011-07-01 2009-07-01 true [Reserved] 408.23 Section 408.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY Conventional Blue Crab Processing...

  7. 40 CFR 408.23 - [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 30 2012-07-01 2012-07-01 false [Reserved] 408.23 Section 408.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY Conventional Blue Crab Processing...

  8. 40 CFR 408.23 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true [Reserved] 408.23 Section 408.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY Conventional Blue Crab Processing...

  9. 40 CFR 408.23 - [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 29 2014-07-01 2012-07-01 true [Reserved] 408.23 Section 408.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY Conventional Blue Crab Processing...

  10. Hydraulic Fatigue-Testing Machine

    NASA Technical Reports Server (NTRS)

    Hodo, James D.; Moore, Dennis R.; Morris, Thomas F.; Tiller, Newton G.

    1987-01-01

    Fatigue-testing machine applies fluctuating tension to number of specimens at same time. When sample breaks, machine continues to test remaining specimens. Series of tensile tests needed to determine fatigue properties of materials performed more rapidly than in conventional fatigue-testing machine.

  11. 26 CFR 509.117 - Dividends and interest paid by a foreign corporation.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS SWITZERLAND General Income Tax § 509.117 Dividends and interest... Switzerland, or by a Swiss corporation, shall not be included in gross income and shall be exempt from United...

  12. Radiosurgical fistulotomy; an alternative to conventional procedure in fistula in ano.

    PubMed

    Gupta, Pravin J

    2003-01-01

    Most surgeons continue to prefer the classic lay open technique [fistulotomy] as the gold standard of treatment in anal fistula. In this randomized study, a comparison is made between conventional fistulotomy and fistulotomy performed by a radio frequency device. One hundred patients of low anal fistula posted for fistulotomy were randomized prospectively to either a conventional or radio frequency technique. Parameters measured included time taken for the procedure, amount of blood loss, postoperative pain, return to work, and recurrence rate. The patient demographic was comparable in 2 groups. The radio frequency fistulotomy was quicker as compared to a conventional one [22 versus 37 minutes, p = 0.001], amount of bleeding was significantly less [47 ml versus 134 ml, p = 0.002], and hospital stay was less when patient was operated by radio frequency method [37 hours versus 56 hours in conventional method, p = 0.001]. The postoperative pain in the first 24 hours was more in conventional group [2 to 5 versus 0 to 3 on visual analogue scale]. The patients from radio frequency group resumed their duties early with a reduced healing period of the wounds [47 versus 64 days, p = 0.01]. The recurrence or failure rates were comparable in the radio frequency and conventional groups [2% versus 6%]. Fistulotomy procedure using a radio frequency technique has significant advantages over a conventional procedure with regard to operation time, blood loss, return to normal activity, and healing time of the wound.

  13. A survey of Canadian regulated complementary and alternative medicine schools about research, evidence-based health care and interprofessional training, as well as continuing education

    PubMed Central

    2013-01-01

    Background While some effort has been made to integrate complementary and alternative medicine (CAM) information in conventional biomedical training, it is unclear whether regulated Canadian CAM schools’ students are exposed to research activities and continuing education, or whether topics such as evidence-based health care and interprofessional collaboration (IPC) are covered during their training. Since these areas are valued by the biomedical training field, this may help to bridge the attitudinal and communication gaps between these different practices. The aim of this study was to describe the training offered in these areas and gather the perceptions of curriculum/program directors in regulated Canadian CAM schools. Methods A two-phase study consisting of an electronic survey and subsequent semi-structured telephone interviews was conducted with curriculum/program (C/P) directors in regulated Canadian CAM schools. Questions assessed the extent of the research, evidence-based health care, IPC training and continuing education, as well as the C/P directors’ perceptions about the training. Descriptive statistics were used to describe the schools’, curriculum’s and the C/P directors’ characteristics. Content analysis was conducted on the interview material. Results Twenty-eight C/P directors replied to the electronic survey and 11 participated in the interviews, representing chiropractic, naturopathy, acupuncture and massage therapy schools. Canadian regulated CAM schools offered research and evidence-based health care training as well as opportunities for collaboration with biomedical peers and continuing education to a various extent (58% to 91%). Although directors were generally satisfied with the training offered at their school, they expressed a desire for improvements. They felt future CAM providers should understand research findings and be able to rely on high quality research and to communicate with conventional care providers as well as to engage in continuing education. Limited length of the curriculum was one of the barriers to such improvements. Conclusions These findings seem to reinforce the directors’ interest and the importance of integrating these topics in order to ensure best CAM practices and improve communication between CAM and conventional providers. PMID:24373181

  14. Continuous flow nitration in miniaturized devices

    PubMed Central

    2014-01-01

    Summary This review highlights the state of the art in the field of continuous flow nitration with miniaturized devices. Although nitration has been one of the oldest and most important unit reactions, the advent of miniaturized devices has paved the way for new opportunities to reconsider the conventional approach for exothermic and selectivity sensitive nitration reactions. Four different approaches to flow nitration with microreactors are presented herein and discussed in view of their advantages, limitations and applicability of the information towards scale-up. Selected recent patents that disclose scale-up methodologies for continuous flow nitration are also briefly reviewed. PMID:24605161

  15. Decreased oscillation threshold of a continuous-wave OPO using a semiconductor gain mirror.

    PubMed

    Siltanen, Mikael; Leinonen, Tomi; Halonen, Lauri

    2011-09-26

    We have constructed a singly resonant, continuous-wave optical parametric oscillator, where the signal beam resonates and is amplified by a semiconductor gain mirror. The gain mirror can significantly decrease the oscillation threshold compared to an identical system with conventional mirrors. The largest idler beam tuning range reached by changing the pump laser wavelength alone is from 3.6 to 4.7 µm. The single mode output power is limited but can be continuously scanned for at least 220 GHz by adding optical components in the oscillator cavity for increased stability. © 2011 Optical Society of America

  16. Aortic perforation sustained at laparoscopy.

    PubMed

    Lynn, S C; Katz, A R; Ross, P J

    1982-04-01

    A major type of complication associated with laparoscopic sterilization has been overcome by changing from electrocautery to either the Hulka clip or silicone rubber band technique, but major puncture and laceration injuries continue at the rate of 0.5% to 2%. The only case of major vascular injury incurred in over 4000 laparoscopic sterilization procedures performed from 1974 through 1980 at the Hermann Hospital in Houston, Texas is reported. A 40-year-old white female, para 3-0-1-3, was admitted for a laparoscopic sterilization procedure. The physical examination was within normal limits. The procedure was carried out by insufflating the peritoneal cavity with 2 liters of CO2 through a 12-cm Verres needle placed subumbilically while testing the abdomen with towel clips. Insufflating pressure never rose above 15 mm of mercury, and an adequate pneumoperitoneum was obtained. With the patient in the Trendelenburg position the trocar was inserted and the laparoscope placed with no apparent difficulty. The Falope Ring applicator sleeve was inserted suprapublically under direct vision. After placing the rings bilaterally, the cul-de-sac was noted to contain approximately 300 cc of blood. This was aspirated, but blood slowly reaccumulated in the cul-de-sac. Laparoscopic examination provided inadequate visualization of the posterior surface of the mesosalpinges, and it was decided to perform laparotomy. Upon opening the abdomen, the pulse rose from 85 to 110 per minute and the blood pressure fell from 90/60 to 50/0 mm HG. Rapid infusion of isotonic crystalloid and 3 units of packed red blood cells restored the patient's vital signs to normal. Examination of the abdominal wall and pelvic organs was normal, but a retroperitoneal hematoma was discovered in the area of the sacral promontroy. The posterior peritoneum was opened, and a 13 x 15-cm hematoma was evacuated. A 3-mm puncture wound was noted in the anterior wall of the aorta 3 cm cephalad to the bifurcation. The square defect was isolated with vascular clamps and repaired with a single layer of simple interrupted Prolene sutures. Abdominal exploration revealed a 3-mm defect in the small bowel mesentery that was repaired with interrupted chromic sutures, and the abdomen was closed. This report illustrates the perpetual caution that must be exercised in the performance of a routine gynecologic procedure. The blind puncture of the abdominal wall with the Verres needle and the laparoscope trocar must be performed with great care.

  17. Modeling terrestrial gamma ray flashes produced by relativistic feedback discharges

    NASA Astrophysics Data System (ADS)

    Liu, Ningyu; Dwyer, Joseph R.

    2013-05-01

    This paper reports a modeling study of terrestrial gamma ray flashes (TGFs) produced by relativistic feedback discharges. Terrestrial gamma ray flashes are intense energetic radiation originating from the Earth's atmosphere that has been observed by spacecraft. They are produced by bremsstrahlung interactions of energetic electrons, known as runaway electrons, with air atoms. An efficient physical mechanism for producing large fluxes of the runaway electrons to make the TGFs is the relativistic feedback discharge, where seed runaway electrons are generated by positrons and X-rays, products of the discharge itself. Once the relativistic feedback discharge becomes self-sustaining, an exponentially increasing number of relativistic electron avalanches propagate through the same high-field region inside the thundercloud until the electric field is partially discharged by the ionization created by the discharge. The modeling results indicate that the durations of the TGF pulses produced by the relativistic feedback discharge vary from tens of microseconds to several milliseconds, encompassing all durations of the TGFs observed so far. In addition, when a sufficiently large potential difference is available in thunderclouds, a self-propagating discharge known as the relativistic feedback streamer can be formed, which propagates like a conventional positive streamer. For the relativistic feedback streamer, the positive feedback mechanism of runaway electron production by the positrons and X-rays plays a similar role as the photoionization for the conventional positive streamer. The simulation results of the relativistic feedback streamer show that a sequence of TGF pulses with varying durations can be produced by the streamer. The relativistic streamer may initially propagate with a pulsed manner and turn into a continuous propagation mode at a later stage. Milliseconds long TGF pulses can be produced by the feedback streamer during its continuous propagation. However, the continuous propagation of the streamer tends to be unstable, because it does not expand like the conventional positive streamer. Its head electric field continues to increase and can reach half of the conventional breakdown threshold field, which results in an ion density of 3- 10×1014m-3 in the channel immediately following the head. The spatial width of the high field region in the streamer head is about 100 m and the streamer speed is about 5×105 m/s. As a result, conventional positive streamers can be initiated from thundercloud hydrometeors or inhomogeneities of enhanced conductivities of millimeter sizes in the relativistic feedback streamer head and the positive streamers may further result in the formation of leaders. In addition, a relativistic feedback streamer can result in a charge moment change of several tens of coulomb-kilometers in a few tens of milliseconds, indicating that the relativistic feedback discharge process could be an important component for thundercloud charge dynamics.

  18. An approach for the regularization of a power flow solution around the maximum loading point

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kataoka, Y.

    1992-08-01

    In the conventional power flow solution, the boundary conditions are directly specified by active power and reactive power at each node, so that the singular point coincided with the maximum loading point. For this reason, the computations are often disturbed by ill-condition. This paper proposes a new method for getting the wide-range regularity by giving some modifications to the conventional power flow solution method, thereby eliminating the singular point or shifting it to the region with the voltage lower than that of the maximum loading point. Then, the continuous execution of V-P curves including maximum loading point is realized. Themore » efficiency and effectiveness of the method are tested in practical 598-nodes system in comparison with the conventional method.« less

  19. Continuous DC-CIK infusions restore CD8+ cellular immunity, physical activity and improve clinical efficacy in advanced cancer patients unresponsive to conventional treatments.

    PubMed

    Zhao, Yan-Jie; Jiang, Ni; Song, Qing-Kun; Wu, Jiang-Ping; Song, Yu-Guang; Zhang, Hong-Mei; Chen, Feng; Zhou, Lei; Wang, Xiao-Li; Zhou, Xin-Na; Yang, Hua-Bing; Ren, Jun; Lyerly, Herbert Kim

    2015-01-01

    There are few choices for treatment of advanced cancer patients who do not respond to or tolerate conventional anti-cancer treatments. Therefore this study aimed to deploy the benefits and clinical efficacy of continuous dendritic cell-cytokine induced killer cell infusions in such patients. A total of 381 infusions (from 67 advanced cases recruited) were included in this study. All patients underwent peripheral blood mononuclear cell apheresis for the following cellular therapy and dendritic cells-cytokine induced killer cells were expanded in vitro. Peripheral blood T lymphocyte subsets were quantified through flow cytometry to address the cellular immunity status. Clinical efficacy and physical activities were evaluated by RECIST criteria and Eastern Cooperative Oncology Group scores respectively. Logistic regression model was used to estimate the association between cellular infusions and clinical benefits. An average of 5.7±2.94x10(9) induced cells were infused each time and patients were exposed to 6 infusions. Cellular immunity was improved in that cytotoxic CD8+CD28+T lymphocytes were increased by 74% and suppressive CD8+CD28-T lymphocytes were elevated by 16% (p<0.05). Continuous infusion of dendritic cells-cytokine induced killer cells was associated with improvement of both patient status and cellular immunity. A median of six infusions were capable of reducing risk of progression by 70% (95%CI 0.10-0.91). Every elevation of one ECOG score corresponded to a 3.90-fold higher progression risk (p<0.05) and 1% increase of CD8+CD28- T cell proportion reflecting a 5% higher risk of progression (p<0.05). In advanced cancer patients, continuous dendritic cell-cytokine induced killer cell infusions are capable of recovering cellular immunity, improving patient status and quality of life in those who are unresponsive to conventional cancer treatment.

  20. Inter-Slice Blood Flow and Magnetization Transfer Effects as A New Simultaneous Imaging Strategy.

    PubMed

    Han, Paul Kyu; Barker, Jeffrey W; Kim, Ki Hwan; Choi, Seung Hong; Bae, Kyongtae Ty; Park, Sung-Hong

    2015-01-01

    The recent blood flow and magnetization transfer (MT) technique termed alternate ascending/descending directional navigation (ALADDIN) achieves the contrast using interslice blood flow and MT effects with no separate preparation RF pulse, thereby potentially overcoming limitations of conventional methods. In this study, we examined the signal characteristics of ALADDIN as a simultaneous blood flow and MT imaging strategy, by comparing it with pseudo-continuous ASL (pCASL) and conventional MT asymmetry (MTA) methods, all of which had the same bSSFP readout. Bloch-equation simulations and experiments showed ALADDIN perfusion signals increased with flip angle, whereas MTA signals peaked at flip angle around 45°-60°. ALADDIN provided signals comparable to those of pCASL and conventional MTA methods emulating the first, second, and third prior slices of ALADDIN under the same scan conditions, suggesting ALADDIN signals to be superposition of signals from multiple labeling planes. The quantitative cerebral blood flow signals from a modified continuous ASL model overestimated the perfusion signals compared to those measured with a pulsed ASL method. Simultaneous mapping of blood flow, MTA, and MT ratio in the whole brain is feasible with ALADDIN within a clinically reasonable time, which can potentially help diagnosis of various diseases.

  1. "Biocompatible" Neutral pH Low-GDP Peritoneal Dialysis Solutions: Much Ado About Nothing?

    PubMed

    Misra, Paraish S; Nessim, Sharon J; Perl, Jeffrey

    2017-03-01

    Adverse outcomes in peritoneal dialysis (PD), including PD related infections, the loss of residual kidney function (RKF), and longitudinal, deleterious changes in peritoneal membrane function continue to limit the long-term success of PD therapy. The observation that these deleterious changes occur upon exposure to conventional glucose-based PD solutions fuels the search for a more biocompatible PD solution. The development of a novel PD solution with a neutral pH, and lower in glucose degradation products (GDPs) compared to its conventional predecessors has been labeled a "biocompatible" solution. While considerable evidence in support of these novel solutions' biocompatibility has emerged from cell culture and animal studies, the clinical benefits as compared to conventional PD solutions are less clear. Neutral pH low GDP (NpHLGDP) PD solutions appear to be effective in reducing infusion pain, but their effects on other clinical endpoints including peritoneal membrane function, preservation of RKF, PD-related infections, and technique and patient survival are less clear. The literature is limited by studies characterized by relatively few patients, short follow-up time, heterogeneity with regards to the novel PD solution type under study, and the different patient populations under study. Nonetheless, the search for a more biocompatible PD solution continues with emerging data on promising non glucose-based solutions. © 2017 Wiley Periodicals, Inc.

  2. Modulated and continuous-wave operations of low-power thulium (Tm:YAP) laser in tissue welding

    NASA Astrophysics Data System (ADS)

    Bilici, Temel; Tabakoğlu, Haşim Özgür; Topaloğlu, Nermin; Kalaycıoğlu, Hamit; Kurt, Adnan; Sennaroglu, Alphan; Gülsoy, Murat

    2010-05-01

    Our aim is to explore the welding capabilities of a thulium (Tm:YAP) laser in modulated and continuous-wave (CW) modes of operation. The Tm:YAP laser system developed for this study includes a Tm:YAP laser resonator, diode laser driver, water chiller, modulation controller unit, and acquisition/control software. Full-thickness incisions on Wistar rat skin were welded by the Tm:YAP laser system at 100 mW and 5 s in both modulated and CW modes of operation (34.66 W/cm2). The skin samples were examined during a 21-day healing period by histology and tensile tests. The results were compared with the samples closed by conventional suture technique. For the laser groups, immediate closure at the surface layers of the incisions was observed. Full closures were observed for both modulated and CW modes of operation at day 4. The tensile forces for both modulated and CW modes of operation were found to be significantly higher than the values found by conventional suture technique. The 1980-nm Tm:YAP laser system operating in both modulated and CW modes maximizes the therapeutic effect while minimizing undesired side effects of laser tissue welding. Hence, it is a potentially important alternative tool to the conventional suturing technique.

  3. Development of Mackintosh Probe Extractor

    NASA Astrophysics Data System (ADS)

    Rahman, Noor Khazanah A.; Kaamin, Masiri; Suwandi, Amir Khan; Sahat, Suhaila; Jahaya Kesot, Mohd

    2016-11-01

    Dynamic probing is a continuous soil investigation technique, which is one of the simplest soil penetration test. It basically consist of repeatedly driving a metal tipped probe into the ground using a drop weight of fixed mass and travel. Testing was carried out continuously from ground level to the final penetration depth. Once the soil investigation work done, it is difficult to pull out the probe rod from the ground, due to strong soil structure grip against probe cone and prevent the probe rod out from the ground. Thus, in this case, a tool named Extracting Probe was created to assist in the process of retracting the probe rod from the ground. In addition, Extracting Probe also can reduce the time to extract the probe rod from the ground compare with the conventional method. At the same time, it also can reduce manpower cost because only one worker involve to handle this tool compare with conventional method used two or more workers. From experiment that have been done we found that the time difference between conventional tools and extracting probe is significant, average time difference is 155 minutes. In addition the extracting probe can reduce manpower usage, and also labour cost for operating the tool. With all these advantages makes this tool has the potential to be marketed.

  4. Ultrasonic-generated fluid velocity with Sovereign WhiteStar micropulse and continuous phacoemulsification.

    PubMed

    Steinert, Roger F; Schafer, Mark E

    2006-02-01

    To evaluate and compare ultrasonic turbulence created by conventional and micropulse ultrasound technology. Sonora Medical Systems, Longmont, Colorado, USA. A high-resolution digital ultrasound probe imaged the zone around a phacoemulsification tip. Doppler analysis allowed determination of flow. The fluid velocity was measured at 4 levels of ultrasound power at a constant flow, comparing the ultrasonic conditions of continuous energy to WhiteStar micropulses. In addition to the normal baseline irrigation and aspiration, fluid movement was detected directly below the phaco tip, produced by a nonlinear effect known as acoustic streaming. Acoustic streaming increased with increased phacoemulsification power for both conditions. At each of the 4 levels of power, fluid velocity away from the tip was less with micropulse technology than with continuous phacoemulsification. The demonstrated decrease in acoustic streaming flow away from the phaco tip with Sovereign WhiteStar micropulse technology compared to conventional ultrasound provides an objective explanation for clinical observations of increased stability of nuclear fragments at the tip and less turbulence in the anterior chamber during phacoemulsification. This methodology can be used to examine and compare fluid flow and turbulence under a variety of clinically relevant conditions.

  5. 40 CFR 408.21 - Specialized definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Specialized definitions. 408.21 Section 408.21 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY Conventional Blue Crab Processing...

  6. 40 CFR 408.21 - Specialized definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Specialized definitions. 408.21 Section 408.21 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY Conventional Blue Crab Processing...

  7. 40 CFR 408.21 - Specialized definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Specialized definitions. 408.21 Section 408.21 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY Conventional Blue Crab Processing...

  8. 40 CFR 408.21 - Specialized definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Specialized definitions. 408.21 Section 408.21 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY Conventional Blue Crab Processing...

  9. 7 CFR 1221.117 - Exemptions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... qualify for exemption. Reasons for conventional sales include lack of demand for organic products... Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... assessments. (g) A producer or importer who operates under an approved National Organic Program (NOP) (7 CFR...

  10. 40 CFR 141.718 - Treatment performance toolbox components.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Treatment for.... (a) Combined filter performance. Systems using conventional filtration treatment or direct filtration... the criteria in this paragraph. Combined filter effluent (CFE) turbidity must be less than or equal to...

  11. 40 CFR 141.718 - Treatment performance toolbox components.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Treatment for.... (a) Combined filter performance. Systems using conventional filtration treatment or direct filtration... the criteria in this paragraph. Combined filter effluent (CFE) turbidity must be less than or equal to...

  12. 40 CFR 141.718 - Treatment performance toolbox components.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Enhanced Treatment for.... (a) Combined filter performance. Systems using conventional filtration treatment or direct filtration... the criteria in this paragraph. Combined filter effluent (CFE) turbidity must be less than or equal to...

  13. Pauson-Khand reactions in a photochemical flow microreactor.

    PubMed

    Asano, Keisuke; Uesugi, Yuki; Yoshida, Jun-ichi

    2013-05-17

    Pauson-Khand reactions were achieved at ambient temperature without any additive using a photochemical flow microreactor. The efficiency of the reaction was better than that in a conventional batch reactor, and the reaction could be operated continuously for 1 h.

  14. 47 CFR 22.731 - Emission limitations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Emission limitations. 22.731 Section 22.731 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES PUBLIC MOBILE SERVICES Rural Radiotelephone Service Conventional Rural Radiotelephone Stations § 22.731 Emission limitations. Upon application...

  15. 15 CFR 718.2 - Identification of confidential business information.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... business information. 718.2 Section 718.2 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS CONFIDENTIAL BUSINESS INFORMATION 718.2 Identification of confidential business...

  16. Antireflux Versus Conventional Plastic Stent in Malignant Biliary Obstruction: A Prospective Randomized Study.

    PubMed

    Vihervaara, Hanna; Grönroos, Juha M; Hurme, Saija; Gullichsen, Risto; Salminen, Paulina

    2017-01-01

    Endoscopic stents are used to relieve obstructive jaundice. The purpose of this prospective randomized study was to compare the patency of antireflux and conventional plastic biliary stent in relieving distal malignant biliary obstruction. All jaundiced patients admitted to hospital with suspected unresectable malignant distal biliary stricture between October 2009 and September 2010 were evaluated for the study. Eligible patients were randomized either to antireflux or conventional plastic stent arms. The primary endpoint was stent patency and the follow-up was continued either until the stent was occluded or until 6 months after the stent placement. At an interim analysis, antireflux stents (ARSs; n = 6) had a significantly shorter median patency of 34 (8-49) days compared with the conventional stent (n = 7) patency of 167 (38-214) days (P = .0003). Based on these results, the study was terminated due to ethical concerns. According to these results, the use of this ARS is not recommended.

  17. An alternative local anaesthesia technique to reduce pain in paediatric patients during needle insertion.

    PubMed

    Lee, S H; Lee, N Y

    2013-06-01

    Pain control, which is necessary during most dental procedures, is administered by injecting a local anaesthetic. Because the injection itself can be painful, the procedure via which pain is reduced warrants continued investigation. Only a few studies regarding the reaction of children to dental needle insertion without the use of topical anaesthetics have been reported. This study was conducted to evaluate the efficacy of the local anaesthetic procedure without topical application as compared to the conventional insertion technique for alleviating pain in children receiving local anaesthesia injections. For the alternative injection procedure, the dentist quickly and gently pulled or pushed the clean and dried loose tissue at the injection site over the tip of the needle to a depth of 1 to 1.5 mm. When the end of the bevel of the needle tip entered the tissue, a few drops of solution were released, after which the needle was advanced to its proper and intended depth to continue anaesthetic release. There was a significant difference regarding the pain response between the alternative insertion technique (less painful) and the conventional one according to Sound, Eye, and Motor (SEM) scale ratings (P < 0.000). No significant difference was observed in the response between the maxilla and mandible, nor between boys and girls, between the conventional and alternative techniques. This alternative technique can reduce discomfort in paediatric dental patients and allow the clinician to administer a superficial local anaesthesia injection before the needle is advanced into deeper tissue. This technique is simple, quick, devoid of additional costs, and potentially more effective than the conventional needle insertion method.

  18. Continuous-flow retro-Diels-Alder reaction: an efficient method for the preparation of pyrimidinone derivatives.

    PubMed

    Nekkaa, Imane; Palkó, Márta; Mándity, István M; Fülöp, Ferenc

    2018-01-01

    The syntheses of various pyrimidinones as potentially bioactive products by means of the highly controlled continuous-flow retro-Diels-Alder reaction of condensed pyrimidinone derivatives are presented. Noteworthy, the use of this approach allowed us to rapidly screen a selection of conditions and quickly confirm the viability of preparing the desired pyrimidinones in short reaction times. Yields typically higher than those published earlier using conventional batch or microwave processes were achieved.

  19. Student views on continuous assessment at Birmingham University Medical School.

    PubMed Central

    Cruickshank, J K; Barritt, P W; Mcbesag, F; Waterhouse, N; Goldman, L H

    1975-01-01

    Student opinion on the system of continuous assessment used at Birmingham Medical School was sampled by distributing questionnaires to 621 students in the first four years of the course; 482 questionnaires (78%) were returned. Many comments and criticisms of the system were received but the vast majority of students (92%) said they preferred the present style of assessment to conventional final examinations. These criticisms are discussed and recommendations are made to improve the existing scheme. PMID:1192017

  20. Assessment of Appalachian basin oil and gas resources: Utica-Lower Paleozoic Total Petroleum System: Chapter G.10 in Coal and petroleum resources in the Appalachian basin: distribution, geologic framework, and geochemical character

    USGS Publications Warehouse

    Ryder, Robert T.; Ruppert, Leslie F.; Ryder, Robert T.

    2014-01-01

    Both conventional oil and gas resources and continuous (unconventional) gas resources are present in the UticaLower Paleozoic TPS. Conventional oil and gas resources in the Utica-Lower Paleozoic TPS were assessed by the U.S. Geological Survey (USGS) in 2002 in the following assessment units (AU): (1) the Lower Paleozoic Carbonates in Thrust Belt AU, (2) the Knox Unconformity AU, (3) the Black River-Trenton Hydrothermal Dolomite AU, and (4) the Lockport Dolomite AU. The total estimated undiscovered oil and gas resources for these four AUs, at a mean value, was about 46 million barrels of oil (MMBO) and about 3 trillion cubic feet of gas (TCFG), respectively. In contrast, continuous (unconventional) gas resources in the TPS were assessed by the USGS in 2002 in four AUs associated with the “Clinton” sandstone, Medina sandstone, Medina Group sandstones, Tuscarora Sandstone, and sandstones in the Queenston Shale. The total estimated undiscovered gas for these four AUs, at a mean value, was about 26.8 TCFG. A hypothetical Utica Shale AU for oil(?) and continuous gas is identified in this report. In 2012, the Utica Shale was recognized by the USGS as a continuous AU and was assessed by Kirschbaum and others (2012).

  1. Interfacing Lab-on-a-Chip Embryo Technology with High-Definition Imaging Cytometry.

    PubMed

    Zhu, Feng; Hall, Christopher J; Crosier, Philip S; Wlodkowic, Donald

    2015-08-01

    To spearhead deployment of zebrafish embryo biotests in large-scale drug discovery studies, automated platforms are needed to integrate embryo in-test positioning and immobilization (suitable for high-content imaging) with fluidic modules for continuous drug and medium delivery under microperfusion to developing embryos. In this work, we present an innovative design of a high-throughput three-dimensional (3D) microfluidic chip-based device for automated immobilization and culture and time-lapse imaging of developing zebrafish embryos under continuous microperfusion. The 3D Lab-on-a-Chip array was fabricated in poly(methyl methacrylate) (PMMA) transparent thermoplastic using infrared laser micromachining, while the off-chip interfaces were fabricated using additive manufacturing processes (fused deposition modelling and stereolithography). The system's design facilitated rapid loading and immobilization of a large number of embryos in predefined clusters of traps during continuous microperfusion of drugs/toxins. It was conceptually designed to seamlessly interface with both upright and inverted fluorescent imaging systems and also to directly interface with conventional microtiter plate readers that accept 96-well plates. Compared with the conventional Petri dish assays, the chip-based bioassay was much more convenient and efficient as only small amounts of drug solutions were required for the whole perfusion system running continuously over 72 h. Embryos were spatially separated in the traps that assisted tracing single embryos, preventing interembryo contamination and improving imaging accessibility.

  2. 46 CFR 50.01-10 - Purpose of regulations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL PROVISIONS... in this subchapter is to set forth minimum requirements for marine engineering details for various... thereof or supplemental thereto as well as to implement various international conventions for safety of...

  3. 46 CFR 50.01-10 - Purpose of regulations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL PROVISIONS... in this subchapter is to set forth minimum requirements for marine engineering details for various... thereof or supplemental thereto as well as to implement various international conventions for safety of...

  4. 46 CFR 50.01-10 - Purpose of regulations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL PROVISIONS... in this subchapter is to set forth minimum requirements for marine engineering details for various... thereof or supplemental thereto as well as to implement various international conventions for safety of...

  5. 46 CFR 50.01-10 - Purpose of regulations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL PROVISIONS... in this subchapter is to set forth minimum requirements for marine engineering details for various... thereof or supplemental thereto as well as to implement various international conventions for safety of...

  6. 46 CFR 50.01-10 - Purpose of regulations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING GENERAL PROVISIONS... in this subchapter is to set forth minimum requirements for marine engineering details for various... thereof or supplemental thereto as well as to implement various international conventions for safety of...

  7. PROCESS INTENSIFICATION: OXIDATION OF BENZYL ALCOHOL USING A CONTINUOUS ISOTHERMAL REACTOR UNDER MICROWAVE IRRADIATION

    EPA Science Inventory

    In the past two decades, several investigations have been carried out using microwave radiation for performing chemical transformations. These transformations have been largely performed in conventional batch reactors with limited mixing and heat transfer capabilities. The reacti...

  8. 7 CFR 1150.157 - Assessment exemption.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... plan; produces only products that are eligible to be labeled as 100 percent organic under the NOP.... Reasons for conventional sales include lack of demand for organic products, isolated use of antibiotics... Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing...

  9. 47 CFR 80.305 - Watch requirements of the Communications Act and the Safety Convention.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... having a loudspeaker and a radiotelephone auto alarm must be used to keep the continuous watch on 2182 k... navigation of the ship, the watch may be maintained by use of the radiotelephone auto alarm facility alone...

  10. 26 CFR 514.4 - Interest.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS FRANCE... nonresident alien individual, fiduciary, and partnership) who is a resident of France, or by a French... bond interest, the nonresident alien who is a resident of France, or the French corporation or other...

  11. 15 CFR 719.15 - Procedural stipulations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Procedural stipulations. 719.15 Section 719.15 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  12. 15 CFR 719.13 - Prehearing conference.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Prehearing conference. 719.13 Section 719.13 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  13. 15 CFR 719.13 - Prehearing conference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Prehearing conference. 719.13 Section 719.13 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  14. 15 CFR 719.15 - Procedural stipulations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Procedural stipulations. 719.15 Section 719.15 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  15. 15 CFR 717.2 - Challenge inspections.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Challenge inspections. 717.2 Section 717.2 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS CWC...

  16. System Study for Axial Vane Engine Technology

    NASA Technical Reports Server (NTRS)

    Badley, Patrick R.; Smith, Michael R.; Gould, Cedric O.

    2008-01-01

    The purpose of this engine feasibility study was to determine the benefits that can be achieved by incorporating positive displacement axial vane compression and expansion stages into high bypass turbofan engines. These positive-displacement stages would replace some or all of the conventional compressor and turbine stages in the turbine engine, but not the fan. The study considered combustion occurring internal to an axial vane component (i.e., Diesel engine replacing the standard turbine engine combustor, burner, and turbine); and external continuous flow combustion with an axial vane compressor and an axial vane turbine replacing conventional compressor and turbine systems.

  17. Assessment of undiscovered oil and gas resources in sandstone reservoirs of the Cotton Valley Group, U.S. Gulf Coast, 2015

    USGS Publications Warehouse

    Eoff, Jennifer D.; Biewick, Laura R.H.; Brownfield, Michael E.; Burke, Lauri; Charpentier, Ronald R.; Dubiel, Russell F.; Gaswirth, Stephanie B.; Gianoutsos, Nicholas J.; Kinney, Scott A.; Klett, Timothy R.; Leathers, Heidi M.; Mercier, Tracey J.; Paxton, Stanley T.; Pearson, Ofori N.; Pitman, Janet K.; Schenk, Christopher J.; Tennyson, Marilyn E.; Whidden, Katherine J.

    2015-08-11

    Using a geology-based assessment methodology, the U.S. Geological Survey estimated undiscovered mean volumes of 14 million barrels of conventional oil, 430 billion cubic feet of conventional gas, 34,028 billion cubic feet of continuous gas, and a mean total of 391 million barrels of natural gas liquids in sandstone reservoirs of the Upper Jurassic–Lower Cretaceous Cotton Valley Group in onshore lands and State waters of the U.S. Gulf Coast region.

  18. Generation conditions of CW Diode Laser Sustained Plasma

    NASA Astrophysics Data System (ADS)

    Nishimoto, Koji; Matsui, Makoto; Ono, Takahiro

    2016-09-01

    Laser sustained plasma was generated using 1 kW class continuous wave diode laser. The laser beam was focused on the seed plasma generated by arc discharge in 1 MPa xenon lamp. The diode laser has advantages of high energy conversion efficiency of 80%, ease of maintenance, compact size and availability of conventional quartz based optics. Therefore, it has a prospect of further development compared with conventional CO2 laser. In this study, variation of the plasma shape caused by laser power is observed and also temperature distribution in the direction of plasma radius is measured by optical emission spectroscopy.

  19. Identification of Technological Parameters of Ni-Alloys When Machining by Monolithic Ceramic Milling Tool

    NASA Astrophysics Data System (ADS)

    Czán, Andrej; Kubala, Ondrej; Danis, Igor; Czánová, Tatiana; Holubják, Jozef; Mikloš, Matej

    2017-12-01

    The ever-increasing production and the usage of hard-to-machine progressive materials are the main cause of continual finding of new ways and methods of machining. One of these ways is the ceramic milling tool, which combines the pros of conventional ceramic cutting materials and pros of conventional coating steel-based insert. These properties allow to improve cutting conditions and so increase the productivity with preserved quality known from conventional tools usage. In this paper, there is made the identification of properties and possibilities of this tool when machining of hard-to-machine materials such as nickel alloys using in airplanes engines. This article is focused on the analysis and evaluation ordinary technological parameters and surface quality, mainly roughness of surface and quality of machined surface and tool wearing.

  20. Solar energy system economic evaluation for Wormser Columbia, South Carolina

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The Solar Energy System is not economically beneficial under the assumed economic conditions at the sites considered. Economic benefits from this system depend on decreasing the initial investment and the continued increase in the cost of conventional energy. Decreasing the cost depends on favorable tax treatment and continuing development of solar energy technology. Fuel cost would have to increase drastically while the cost of the system would have to remain constant or decrease for the system to become economically feasible.

  1. Global energy consumption and production in 2000

    NASA Astrophysics Data System (ADS)

    Allen, E. L.; Davison, C.; Dougher, R.; Edmonds, J. A.; Reilly, J.

    1981-02-01

    This study anticipates that global energy demand will continue to expand through 2000, although at a slower pace than in 1965 to 1978. Growth of supply is expected to be largely in conventional, nonrenewable fuels - coal, oil, uranium, and natural gas. Energy growth is also expected to slow down in terms of energy consumption per unit of output as a consequence of continuing efficiency improvements, which, in turn, result from higher energy prices. Slower rates of economic growth are expected in all groups of countries, developed and underdeveloped.

  2. Fourier Deconvolution Methods for Resolution Enhancement in Continuous-Wave EPR Spectroscopy.

    PubMed

    Reed, George H; Poyner, Russell R

    2015-01-01

    An overview of resolution enhancement of conventional, field-swept, continuous-wave electron paramagnetic resonance spectra using Fourier transform-based deconvolution methods is presented. Basic steps that are involved in resolution enhancement of calculated spectra using an implementation based on complex discrete Fourier transform algorithms are illustrated. Advantages and limitations of the method are discussed. An application to an experimentally obtained spectrum is provided to illustrate the power of the method for resolving overlapped transitions. © 2015 Elsevier Inc. All rights reserved.

  3. Imaging Through Random Discrete-Scatterer Dispersive Media

    DTIC Science & Technology

    2015-08-27

    to that of a conventional, continuous, linear - frequency-modulated chirped signal [3]. Chirped train signals are a particular realization of a class of...continuous chirp signals, characterized by linear frequency modulation [3], we assume the time instances tn to be given by 1 tn = τg ( 1− βg n 2Ng ) n...kernel Dn(z) [9] by sincN (z) = (N + 1)−1DN/2(2πz/N). DISTRIBUTION A: Distribution approved for public release. 4 We use the elementary identity5 π sin

  4. Continuous-flow retro-Diels–Alder reaction: an efficient method for the preparation of pyrimidinone derivatives

    PubMed Central

    Nekkaa, Imane; Palkó, Márta; Mándity, István M

    2018-01-01

    The syntheses of various pyrimidinones as potentially bioactive products by means of the highly controlled continuous-flow retro-Diels–Alder reaction of condensed pyrimidinone derivatives are presented. Noteworthy, the use of this approach allowed us to rapidly screen a selection of conditions and quickly confirm the viability of preparing the desired pyrimidinones in short reaction times. Yields typically higher than those published earlier using conventional batch or microwave processes were achieved. PMID:29507637

  5. Diels–Alder reactions of myrcene using intensified continuous-flow reactors

    PubMed Central

    Álvarez-Diéguez, Miguel Á; Kohl, Thomas M; Tsanaktsidis, John

    2017-01-01

    This work describes the Diels–Alder reaction of the naturally occurring substituted butadiene, myrcene, with a range of different naturally occurring and synthetic dienophiles. The synthesis of the Diels–Alder adduct from myrcene and acrylic acid, containing surfactant properties, was scaled-up in a plate-type continuous-flow reactor with a volume of 105 mL to a throughput of 2.79 kg of the final product per day. This continuous-flow approach provides a facile alternative scale-up route to conventional batch processing, and it helps to intensify the synthesis protocol by applying higher reaction temperatures and shorter reaction times. PMID:28228853

  6. 40 CFR 408.26 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Pretreatment standards for new sources. 408.26 Section 408.26 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY Conventional Blue Crab...

  7. 40 CFR 408.26 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Pretreatment standards for new sources. 408.26 Section 408.26 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY Conventional Blue Crab...

  8. 40 CFR 408.26 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Pretreatment standards for new sources. 408.26 Section 408.26 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY Conventional Blue Crab...

  9. 40 CFR 408.26 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Pretreatment standards for new sources. 408.26 Section 408.26 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY Conventional Blue Crab...

  10. 40 CFR 408.26 - Pretreatment standards for new sources.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Pretreatment standards for new sources. 408.26 Section 408.26 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY Conventional Blue Crab...

  11. 7 CFR 1737.90 - Loan approval requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF... accounting records are adequate. If the records are not adequate, as determined by RUS based on Generally Accepted Accounting Principles or other accounting conventions as deemed necessary by RUS, a provision will...

  12. 7 CFR 1280.406 - Exemption.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... percent organic under the NOP; or an exporter who exports only products that are eligible to be labeled as... conventional sales include lack of demand for organic products, isolated use of antibiotics for humane purposes... Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS...

  13. 7 CFR 1250.530 - Certification of exempt producers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... produces products that are eligible to be labeled as 100 percent organic under the NOP, except as provided... qualify for exemption. Reasons for conventional sales include lack of demand for organic products... 1250.530 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING...

  14. 15 CFR 718.3 - Disclosure of confidential business information.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Disclosure of confidential business... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS CONFIDENTIAL BUSINESS INFORMATION § 718.3 Disclosure of confidential business information. (a) General...

  15. 49 CFR 572.31 - General description.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., titled “Sign Convention for Vehicle Crash Testing”, dated 1994-12. (6) Exterior dimensions of the Hybrid... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES Hybrid III Test Dummy § 572.31 General description. (a) The Hybrid III 50th percentile size dummy consists of components and...

  16. 26 CFR 514.2 - Dividends.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS FRANCE... resident of France when such dividend is so paid, or by a French corporation, shall not exceed 15 percent...) Thus, if a nonresident alien individual who is a resident of France performs personal services within...

  17. 26 CFR 521.113 - Students and apprentices; remittances.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 19 2010-04-01 2010-04-01 false Students and apprentices; remittances. 521.113 Section 521.113 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS DENMARK General Income Tax Taxation of Nonresident Aliens Who Are Residents...

  18. 26 CFR 521.104 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 19 2010-04-01 2010-04-01 false Definitions. 521.104 Section 521.104 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS DENMARK General Income Tax Taxation of Nonresident Aliens Who Are Residents of Denmark and of Danish...

  19. 26 CFR 521.114 - Visiting professors or teachers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 19 2010-04-01 2010-04-01 false Visiting professors or teachers. 521.114 Section 521.114 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS DENMARK General Income Tax Taxation of Nonresident Aliens Who Are Residents...

  20. 46 CFR 174.360 - Calculations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SUBDIVISION AND STABILITY SPECIAL RULES PERTAINING TO SPECIFIC VESSEL TYPES Special Rules Pertaining to Dry Cargo Ships § 174.360 Calculations. Each ship to... for that ship by the International Convention for the Safety of Life at Sea, 1974, as amended, chapter...

  1. Characterization of a combined batch-continuous procedure for the culture of anammox biomass

    USDA-ARS?s Scientific Manuscript database

    Interest in autotrophic nitrogen (N) removal through anaerobic ammonium oxidation (anammox) is increasing in the field of wastewater treatment as a more economic and sustainable alternative than conventional nitrification-denitrification. However, anammox biomass is difficult to enrich, and this can...

  2. 15 CFR 719.19 - Settlement.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Settlement. 719.19 Section 719.19 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ENFORCEMENT § 719.19...

  3. 15 CFR 719.7 - Representation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Representation. 719.7 Section 719.7 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ENFORCEMENT § 719.7...

  4. 15 CFR 719.11 - Subpoenas.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Subpoenas. 719.11 Section 719.11 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ENFORCEMENT § 719.11...

  5. 15 CFR 717.5 - Post-inspection activities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Post-inspection activities. 717.5 Section 717.5 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS CWC...

  6. 15 CFR 719.11 - Subpoenas.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Subpoenas. 719.11 Section 719.11 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ENFORCEMENT § 719.11...

  7. 15 CFR 719.19 - Settlement.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Settlement. 719.19 Section 719.19 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ENFORCEMENT § 719.19...

  8. 15 CFR 719.22 - Reporting a violation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Reporting a violation. 719.22 Section 719.22 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  9. 15 CFR 716.10 - Post-inspection activities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Post-inspection activities. 716.10 Section 716.10 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS INITIAL...

  10. 15 CFR 719.14 - Hearings.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Hearings. 719.14 Section 719.14 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ENFORCEMENT § 719.14...

  11. 15 CFR 719.22 - Reporting a violation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Reporting a violation. 719.22 Section 719.22 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  12. 15 CFR 719.16 - Extension of time.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Extension of time. 719.16 Section 719.16 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ENFORCEMENT...

  13. 15 CFR 719.20 - Record for decision.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Record for decision. 719.20 Section 719.20 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  14. 15 CFR 719.7 - Representation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Representation. 719.7 Section 719.7 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ENFORCEMENT § 719.7...

  15. 15 CFR 719.18 - Decisions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Decisions. 719.18 Section 719.18 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ENFORCEMENT § 719.18...

  16. 15 CFR 721.1 - Inspection of records.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Inspection of records. 721.1 Section 721.1 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS INSPECTION...

  17. 15 CFR 719.17 - Post-hearing submissions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Post-hearing submissions. 719.17 Section 719.17 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  18. 15 CFR 719.16 - Extension of time.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Extension of time. 719.16 Section 719.16 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ENFORCEMENT...

  19. 15 CFR 719.17 - Post-hearing submissions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Post-hearing submissions. 719.17 Section 719.17 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  20. 15 CFR 721.1 - Inspection of records.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Inspection of records. 721.1 Section 721.1 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS INSPECTION...

  1. 15 CFR 719.18 - Decisions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Decisions. 719.18 Section 719.18 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ENFORCEMENT § 719.18...

  2. 15 CFR 719.20 - Record for decision.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Record for decision. 719.20 Section 719.20 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  3. 15 CFR 719.10 - Discovery.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Discovery. 719.10 Section 719.10 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ENFORCEMENT § 719.10...

  4. 15 CFR 716.10 - Post-inspection activities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Post-inspection activities. 716.10 Section 716.10 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS INITIAL...

  5. Classrooms Are Killing Learning.

    ERIC Educational Resources Information Center

    Hart, Leslie A.

    1981-01-01

    From his knowledge of the brain and learning, the author argues that Horace Mann's classroom system is the core cause for the outdated state of public education and attendant problems. He asserts that the conventional classroom is brain-antagonistic and the continued use of graded classrooms, ruinous. (Author/WD)

  6. 26 CFR 521.104 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 19 2011-04-01 2010-04-01 true Definitions. 521.104 Section 521.104 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS DENMARK General Income Tax Taxation of Nonresident Aliens Who Are Residents of Denmark and of Danish...

  7. 26 CFR 521.113 - Students and apprentices; remittances.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 19 2011-04-01 2010-04-01 true Students and apprentices; remittances. 521.113 Section 521.113 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS DENMARK General Income Tax Taxation of Nonresident Aliens Who Are Residents...

  8. Mathematical modeling of methyl ester concentration distribution in a continuous membrane tubular reactor and comparison with conventional tubular reactor

    NASA Astrophysics Data System (ADS)

    Talaghat, M. R.; Jokar, S. M.; Modarres, E.

    2017-10-01

    The reduction of fossil fuel resources and environmental issues made researchers find alternative fuels include biodiesels. One of the most widely used methods for production of biodiesel on a commercial scale is transesterification method. In this work, the biodiesel production by a transesterification method was modeled. Sodium hydroxide was considered as a catalyst to produce biodiesel from canola oil and methanol in a continuous tubular ceramic membranes reactor. As the Biodiesel production reaction from triglycerides is an equilibrium reaction, the reaction rate constants depend on temperature and related linearly to catalyst concentration. By using the mass balance for a membrane tubular reactor and considering the variation of raw materials and products concentration with time, the set of governing equations were solved by numerical methods. The results clearly show the superiority of membrane reactor than conventional tubular reactors. Afterward, the influences of molar ratio of alcohol to oil, weight percentage of the catalyst, and residence time on the performance of biodiesel production reactor were investigated.

  9. A Novel AMARS Technique for Baseline Wander Removal Applied to Photoplethysmogram.

    PubMed

    Timimi, Ammar A K; Ali, M A Mohd; Chellappan, K

    2017-06-01

    A new digital filter, AMARS (aligning minima of alternating random signal) has been derived using trigonometry to regulate signal pulsations inline. The pulses are randomly presented in continuous signals comprising frequency band lower than the signal's mean rate. Frequency selective filters are conventionally employed to reject frequencies undesired by specific applications. However, these conventional filters only reduce the effects of the rejected range producing a signal superimposed by some baseline wander (BW). In this work, filters of different ranges and techniques were independently configured to preprocess a photoplethysmogram, an optical biosignal of blood volume dynamics, producing wave shapes with several BWs. The AMARS application effectively removed the encountered BWs to assemble similarly aligned trends. The removal implementation was found repeatable in both ear and finger photoplethysmograms, emphasizing the importance of BW removal in biosignal processing in retaining its structural, functional and physiological properties. We also believe that AMARS may be relevant to other biological and continuous signals modulated by similar types of baseline volatility.

  10. The muscle engram: the reflex that limits conventional occlusal treatment.

    PubMed

    Lerman, Martin D

    2011-10-01

    The engram (the masticatory "muscle memory") is shown to be a conditionable reflex whose muscle conditioning lasts less than two minutes, far shorter than previously thought. This reflex, reinforced and stored in the masticatory muscles at every swallow, adjusts masticatory muscle activity to guide the lower arch unerringly into its ICP. These muscle adjustments compensate for the continually changing intemal and external factors that affect the mandible's entry into the ICP. A simple quick experiment described in this article isolates the engram, enabling the reader to see its action clearly for the first time. It is urged that every reader perform this experiment. This experiment shows how the engram, by hiding the masticatory muscles' reaction (the hit-and-slide), limits the success of the therapist in achieving occlusion-muscle compatibility. This finding has major clinical implications. It means that, as regards the muscle aspect of treating occlusion, the dentist treating occlusion conventionally is working blind, a situation the neuromuscular school of occlusal thought seeks to correct. The controversy over occlusion continues.

  11. The single-staged approach to the surgical management of abdominal wall hernias in contaminated fields.

    PubMed

    Alaedeen, D I; Lipman, J; Medalie, D; Rosen, M J

    2007-02-01

    The surgical treatment of large ventral hernias with accompanying contamination is challenging. We have reviewed our institution's experience with single-staged repair of complex ventral hernias in the setting of contamination. We retrospectively reviewed the medical records of all patients who underwent ventral hernia repairs in the setting of a contaminated field. Pertinent details included baseline demographics, reason for contamination, operative technique and details, postoperative morbidity, mortality and recurrence rates. Between December 1999 and January 2006, 19 patients were identified with ventral hernia repairs performed in contaminated fields. There were 6 males and 13 females with a mean age of 61 years (40-82), ASA 3.2 (2-4), and BMI of 34 kg/m(2) (20-65). Fourteen patients had prior mesh: prolene (9), composix (3), goretex (1), and alloderm (1). Reasons for contamination included: mesh infection (14), enterocutaneous fistula (7), concomitant bowel resection (8), chronic non-healing wound (2), and necrotizing fasciitis (1). Operative approaches included primary repair (3), component separation without reinforcement (2), and with prosthetic reinforcement (9). In five patients the fascia could not be reapproximated in the midline and the defect was bridged with surgisis (1), Marlex (1), lightweight polypropylene (1) placed in the retrorectus space, and alloderm (2). Mean operative time was 260 min (90-600). Twelve postoperative complications occurred in nine (47%) patients and included wound infection (6), respiratory failure (1), ileus (2), postoperative hemorrhage (1), renal failure (1), and atrial fibrillation (1). One patient died in this series. During routine follow-up two recurrences were identified by physical exam. This study shows that single-stage treatment of ventral hernias in contaminated fields can be accomplished with a low recurrence rate and acceptable morbidity in these extremely challenging patients.

  12. Octreotide inhibits hepatic fibrosis, bile duct proliferation and bacterial translocation in obstructive jaundice.

    PubMed

    Türkçapar, Nuran; Bayar, Sancar; Koyuncu, Ayhan; Ceyhan, Koray

    2003-01-01

    The protective effect of octreotide on bacterial translocation, bile duct epithelial proliferation and hepatic fibrosis was studied in an experimental obstructive jaundice model. Forty-five healthy Wistar albino rats were randomly divided into three groups. Group I (n = 15): Median laparotomy and common bile duct manipulation performed (Sham group). Group II (n = 15): Laparotomy and common bile duct ligation performed. Group III (n = 15): After laparotomy and common bile duct ligation octreotide (Sandostatin, sandoz) was given. Simultaneously group I and II received 3 cc 0.9% NaCl and group III received 20 micrograms/kg/daily octreotide subcutaneously every 8 hours during 9 days. Two days after the procedure all rats were opened under ether anesthesia and sterile conditions. Group I had simple laparotomy but group II and III also had common bile duct ligation by 5/0 prolene. Seven days after the surgery (9th day after treatment) all rats underwent laparotomy and tests for bacterial translocation, liver biochemical tests and histopathologic analysis of liver and small bowel were carried out. In group II cecal population levels of bacteria were significantly higher than group I and group III (p < 0.05). In group II there was also statistically significant bacterial translocation to the mesenteric lymph nodes. Pathological changes were found in terminal ileum samples in group II which seemed to improve in group III. Hepatocyte function was preserved with octreotide treatment which also significantly decreased bile duct proliferation and periportal fibrosis in response to biliary obstruction. This experimental study showed that octreotide is effective in preventing bacterial translocation, bile duct proliferation and hepatic fibrosis in obstructive jaundice.

  13. Securing the appendiceal stump with the Gea extracorporeal sliding knot during laparoscopic appendectomy is safe and economical.

    PubMed

    Arcovedo, R; Barrera, H; Reyes, H S

    2007-10-01

    Laparoscopic appendectomy (LA) has become very popular. One criticism of this approach is the high cost of the disposable equipment such as the linear stapler. An alternative would be suture ligation of the appendiceal base. To prove the safety of the Gea extracorporeal sliding knot (GESK) for closure of the stump after LA, a retrospective study was conducted. For this study, 63 LA procedures performed by one surgeon using the Gea knot (group A) were reviewed and compared with 63 LA procedures performed by two other surgeons (group B) using the linear stapler. The GESK is created with 0-prolene in the manner already described. The main variable was the presence or absence of blowout, leak, or fistula from the appendiceal stump. The secondary variables were abdominal abscess, wound infection, and need for readmission or reoperation. The results were analyzed using the appropriate statistical methods. Both groups were similar in terms of age, gender, and pathologic diagnosis. No patient in group A or B experienced a colonic fistula, stump blowout, or leak. In group A, one patient experienced interloop abscesses. There were two wound infections. In group B, one patient experienced a wound infection, and another patient had a wound dehiscence of the umbilical port, which required reoperation. No statistical differences were noted between the two groups. There are surgeons who routinely use sutures to secure the stump of the appendectomy. This study aimed to demonstrate that the GESK is as secure as the stapler for closure of the appendiceal stump. The GESK could be passed through a 5-mm trocar, potentially avoiding complications of a larger trocar site. The GESK seems to be an economic and safe alternative to the stapler.

  14. Challenges in the repair of large abdominal wall hernias in Nigeria: review of available options in resource limited environments.

    PubMed

    Ezeome, E R; Nwajiobi, C E

    2010-06-01

    To evaluate the challenges and outcome of management of large abdominal wall hernias in a resource limited environment and highlight the options available to surgeons in similar conditions. A review of prospectively collected data on large abdominal wall hernias managed between 2003 and 2009. University of Nigeria Teaching Hospital, Enugu, Nigeria and surrounding hospitals. Patients with hernias more than 4 cm in their largest diameter, patients with closely sited multiple hernias or failed previous repairs and in whom the surgeon considers direct repair inappropriate. Demographics of patients with large hernias, methods of hernia repair, recurrences, early and late complications following the repair. There were 41 patients, comprising 28 females and 13 males with ages 14 - 73 years. Most (53.7%) were incisional hernias. Gynecological surgeries (66.7%) were the most common initiating surgeries. Fifteen of the patients (36.6%) have had failed previous repairs, 41.5% were obese, five patients presented with intestinal obstruction. Thirty nine of the hernias were repaired with prolene mesh, one with composite mesh and one by danning technique. Most of the patients had extra peritoneal mesh placement. Three patients needed ventilator support. After a mean follow up of 18.6 months, there was a single failed repair. Two post op deaths were related to respiratory distress. There were 12 wound infection and 8 superficial wound dehiscence, all of which except one resolved with dressing. One reoperation was done following mesh infection and extrusion. Large abdominal wall hernia repair in resource limited environments present several challenges with wound infection and respiratory distress being the most notable. Surgeons who embark on it in these environments must be prepared t o secure the proper tissue replacement materials and have adequate ventilation support.

  15. Pain and quality of life after inguinal hernia surgery: a multicenter randomized controlled trial comparing lightweight vs heavyweight mesh (Supermesh Study).

    PubMed

    Bona, Stefano; Rosati, Riccardo; Opocher, Enrico; Fiore, Barbara; Montorsi, Marco

    2018-03-01

    Mesh repair has significantly reduced recurrence rate after groin hernia surgery. Recently, attention has shifted to issues such as chronic pain and discomfort, leading to development of lightweight and partially re-absorbable meshes. The aim of the study was to evaluate the effect of lightweight mesh vs heavyweight mesh on post-operative pain, discomfort and quality of life in short and medium term after inguinal hernia surgery. Eight hundred and eight patients with primary inguinal hernia were allocated to anterior repair (Lichtenstein technique) using a lightweight mesh (Ultrapro ® ) or a heavyweight mesh (Prolene ® ). Primary outcomes were incidence of chronic pain and discomfort at 6-month follow-up. Secondary endpoints were quality of life (QoL), pain and complication at 1 week, 1 and 6 months. At 6 months, 25% of patients reported pain of some intensity; severe pain was reported by 1% of patients in both groups. A statistically significant difference in favour of lightweight mesh was found at multivariable analysis for pain (1 week and 6 months after surgery: p = 0.02 and p = 0.04, respectively) and QoL at 1 month and 6 months (p = 0.05 and p = 0.02, respectively). There was no difference in complication rate and no hernia recurrences were detected. The use of lightweight mesh in anterior Lichtenstein inguinal hernia repair significantly reduced the incidence of pain and favourably affected the perceived quality of life at 6 months after surgery compared to heavyweight mesh.

  16. Results of a new “mirror tuck technique” for fixation of lacrimal bypass tube in conjunctivodacryocystorhinostomy

    PubMed Central

    Goel, Ruchi; Kishore, Divya; Nagpal, Smriti; Kumar, Sushil; Rathie, Neha

    2017-01-01

    Context: Conjunctivodacryocystorhinostomy (CDCR) is the procedure of choice for proximal canalicular blocks. However, the complications of tube migration and extrusion limit its widespread practice. Aim: The aim of this study is to evaluate the efficacy and complications of the new “mirror tuck technique” for fixation of lacrimal bypass glass tube without holes in proximal canalicular blocks in laser CDCR. Materials and Methods: A prospective interventional study was conducted in forty consecutive eyes of adult patients, undergoing 980 nm diode laser CDCR for proximal canalicular blocks. After creating the tract under endoscopic guidance, the collar of the glass tube was fixed to the conjunctiva with 6-0 prolene suture by “mirror tuck technique.” Success was defined as the absence of extrusion of tube with patent tract and relief in epiphora at 1 year of follow-up. Results: Both anatomical and functional success was achieved in 39 (97.5%) cases. Tube displacement occurred in one patient suffering from allergic conjunctivitis in which the tube had to be removed. A temporary heaviness was reported by 5 (12.5%) patients till about 2 weeks. Conjunctival overgrowth over the tube occurred in 1 (2.5%) eye at 5 months which was excised and treated with application of 0.02% mitomycin C with no subsequent recurrence. There were no cases of suture abscess or suture intolerance warranting tube removal. Conclusion: “Mirror tuck technique” is an effective method for tube fixation (for tube without holes) in CDCR. However, it is important to position the conjunctival opening so as to leave sufficient space for passage of sutures for anchorage medially. PMID:28513491

  17. Physiological and subjective measures of workload when shovelling with a conventional and two-handled ('levered') shovel.

    PubMed

    Bridger, R S; Cabion, N; Goedecke, J; Rickard, S; Schabort, E; Westgarth-Taylor, C; Lambert, M I

    1997-11-01

    Previous studies have suggested that the two-handled (levered) shovel is advantageous over the conventional spade from a biomechanical point of view. The aim of this experiment was to determine whether less energy was consumed while shovelling a load of sand with this shovel compared to a conventional tool. Accordingly, an experiment was designed in which subjects (n = 10) shovelled 1815 kg sand under laboratory conditions using either a conventional or a levered shovel. Heart rate and oxygen consumption were measured continuously during the trial and subjective data on perceived exertion, general fatigue and body discomfort were recorded after the trial. Although total energy expenditure was similar under both conditions (120 +/- 20 and 125 +/- 25 kcal; conventional versus two-handled spade), average heart rate was 4% higher when the two-handled shovel was used (p < 0.05). In addition, the mass of sand per scoop was 4% less with the two-handled shovel (p < 0.05). In conclusion, subjects used similar energy expenditure to shovel 1815 kg sand with the conventional shovel and the two-handled tool despite lower mass of sand per scoop with the latter. This can be explained by the fact that the increased mass of the additional handle compensated for the lower mass of sand per scoop. The higher average heart rate while shovelling with the two-handled shovel can be explained by the more erect posture.

  18. Exploitation of "Excess" Data Now Routinely Collected by Large N, Continuously Recorded Oil Exploration Surveys: From Microseismicity to Deep Crustal Imaging

    NASA Astrophysics Data System (ADS)

    Brown, L. D.

    2014-12-01

    The rapidly expanding use by the oil and gas industry of "nodal", large channel capacity areal arrays that record continuously for extended periods of time is generating large volumes of data in excess of that needed for the conventional CMP reflection imaging that is the primary goal of such surveys. These excess data, once considered as simply "noise", have recently been recognized to have utility not only for the exploration seismologist but also for addressing a diverse range of phenomena. The most widely recognized use for these "noise" records is surface wave tomographic imaging of near surface velocity structure via seismic interferometry of ambient natural noise. Such results are proving to be of great value in enhancing conventional 3D exploration imagery, but they should be appreciated in their own right for the information they provide on the shallow subsurface to the hydrologist, engineer and tectonicist. Another relatively dramatic application is the delineation of local structure by tracing the propagation of body and surface waves from local and teleseismic events across these dense arrays. Here I would like draw attention to three other promising uses for such data: a) detection and mapping of microseismicity below the detection thresholds of conventional earthquake monitoring networks, especially in areas of low conventional seismicity; b) reflection and refraction imaging of structure using cultural, as opposed to natural, energy sources, and c) systematic mapping of the basement in 3D using the existing exploration sources recorded at travel times longer than that typically harvested for resource purposes. We conclude by emphasizing that these potentially invaluable "extras" are now being recorded routinely around the world, but there is as yet no mechanism in place to ensure they are exploited rather than simply deleted.

  19. Renoprotective effects of febuxostat in hyperuricemic patients with chronic kidney disease: a parallel-group, randomized, controlled trial.

    PubMed

    Tanaka, Kenichi; Nakayama, Masaaki; Kanno, Makoto; Kimura, Hiroshi; Watanabe, Kimio; Tani, Yoshihiro; Hayashi, Yoshimitsu; Asahi, Koichi; Terawaki, Hiroyuki; Watanabe, Tsuyoshi

    2015-12-01

    Hyperuricemia is associated with the onset of chronic kidney disease (CKD) and renal disease progression. Febuxostat, a novel, non-purine, selective xanthine oxidase inhibitor, has been reported to have a stronger effect on hyperuricemia than conventional therapy with allopurinol. However, few data are available regarding the clinical effect of febuxostat in patients with CKD. A prospective, randomized, open-label, parallel-group trial was conducted in hyperuricemic patients with stage 3 CKD. Patients were randomly assigned to treatment with febuxostat (n = 21) or to continue conventional therapy (n = 19). Treatment was continued for 12 weeks. The efficacy of febuxostat was determined by monitoring serum uric acid (UA) levels, blood pressures, renal function, and urinary protein levels. In addition, urinary liver-type fatty acid-binding protein (L-FABP), urinary albumin, urinary beta 2 microglobulin (β2MG), and serum high sensitivity C-reactive protein were measured before and 12 weeks after febuxostat was added to the treatment. Febuxostat resulted in a significantly greater reduction in serum UA (-2.2 mg/dL) than conventional therapy (-0.3 mg/dL, P < 0.001). Serum creatinine and estimated glomerular filtration rate changed little during the study period in each group. However, treatment with febuxostat for 12 weeks reduced the urinary levels of L-FABP, albumin, and β2MG, whereas the levels of these markers did not change in the control group. Febuxostat reduced serum UA levels more effectively than conventional therapy and might have a renoprotective effect in hyperuricemic patients with CKD. Further studies should clarify whether febuxostat prevents the progression of renal disease and improves the prognosis of CKD.

  20. Evaluation of lymph node perfusion using continuous mode harmonic ultrasonography with a second-generation contrast agent.

    PubMed

    Rubaltelli, Leopoldo; Khadivi, Yeganeh; Tregnaghi, Alberto; Stramare, Roberto; Ferro, Federica; Borsato, Simonetta; Fiocco, Ugo; Adami, Fausto; Rossi, Carlo Riccardo

    2004-06-01

    To evaluate the contribution of continuous mode contrast-enhanced harmonic ultrasonography (CE-HUS) with a second-generation contrast agent to the characterization of superficial lymphadenopathies with respect to conventional ultrasonographic techniques (B-mode and power Doppler). Fifty-six lymph nodes from 45 patients were studied both by conventional techniques and by CE-HUS. The dimensions, intranodal architecture, margins, and location of vessels were evaluated. Subsequently, all the lymph nodes were examined by CE-HUS, and enhancement of echogenicity was evaluated. The diagnoses obtained by means of fine-needle aspiration cytologic examination, surgical biopsy, or both were compared with those obtained by ultrasonography. Of the lymph nodes examined, 30 were benign and 26 were malignant (18 metastases and 8 non-Hodgkin lymphomas). The study using CE-HUS showed intense homogeneous enhancement in 28 of 30 reactive lymph nodes; perfusion defects in 17, of which 15 were neoplastic and 2 were inflammatory; intense but inhomogeneous speckled enhancement in the early arterial phase in 5 cases of lymphoma; and, last, scarce or absent intranodal enhancement in 4 metastases. The specificity, sensitivity, and accuracy of conventional techniques in differentiation between benign and malignant lymph nodes were 76%, 80%, and 78% versus 93%, 92%, and 92.8% for CE-HUS. The increase in correct diagnoses was significant (P = .05) when conventional ultrasonography was tested against CE-HUS. Superficial lymph nodes can be characterized as being neoplastic or benign with a high degree of diagnostic accuracy on the basis of the perfusion characteristics evaluated by CE-HUS. This technique has been shown to afford a higher degree of accuracy than currently obtainable by any other ultrasonographic technique.

  1. Cardiorespiratory dynamics measured from continuous ECG monitoring improves detection of deterioration in acute care patients: A retrospective cohort study

    PubMed Central

    Clark, Matthew T.; Calland, James Forrest; Enfield, Kyle B.; Voss, John D.; Lake, Douglas E.; Moorman, J. Randall

    2017-01-01

    Background Charted vital signs and laboratory results represent intermittent samples of a patient’s dynamic physiologic state and have been used to calculate early warning scores to identify patients at risk of clinical deterioration. We hypothesized that the addition of cardiorespiratory dynamics measured from continuous electrocardiography (ECG) monitoring to intermittently sampled data improves the predictive validity of models trained to detect clinical deterioration prior to intensive care unit (ICU) transfer or unanticipated death. Methods and findings We analyzed 63 patient-years of ECG data from 8,105 acute care patient admissions at a tertiary care academic medical center. We developed models to predict deterioration resulting in ICU transfer or unanticipated death within the next 24 hours using either vital signs, laboratory results, or cardiorespiratory dynamics from continuous ECG monitoring and also evaluated models using all available data sources. We calculated the predictive validity (C-statistic), the net reclassification improvement, and the probability of achieving the difference in likelihood ratio χ2 for the additional degrees of freedom. The primary outcome occurred 755 times in 586 admissions (7%). We analyzed 395 clinical deteriorations with continuous ECG data in the 24 hours prior to an event. Using only continuous ECG measures resulted in a C-statistic of 0.65, similar to models using only laboratory results and vital signs (0.63 and 0.69 respectively). Addition of continuous ECG measures to models using conventional measurements improved the C-statistic by 0.01 and 0.07; a model integrating all data sources had a C-statistic of 0.73 with categorical net reclassification improvement of 0.09 for a change of 1 decile in risk. The difference in likelihood ratio χ2 between integrated models with and without cardiorespiratory dynamics was 2158 (p value: <0.001). Conclusions Cardiorespiratory dynamics from continuous ECG monitoring detect clinical deterioration in acute care patients and improve performance of conventional models that use only laboratory results and vital signs. PMID:28771487

  2. Cardiorespiratory dynamics measured from continuous ECG monitoring improves detection of deterioration in acute care patients: A retrospective cohort study.

    PubMed

    Moss, Travis J; Clark, Matthew T; Calland, James Forrest; Enfield, Kyle B; Voss, John D; Lake, Douglas E; Moorman, J Randall

    2017-01-01

    Charted vital signs and laboratory results represent intermittent samples of a patient's dynamic physiologic state and have been used to calculate early warning scores to identify patients at risk of clinical deterioration. We hypothesized that the addition of cardiorespiratory dynamics measured from continuous electrocardiography (ECG) monitoring to intermittently sampled data improves the predictive validity of models trained to detect clinical deterioration prior to intensive care unit (ICU) transfer or unanticipated death. We analyzed 63 patient-years of ECG data from 8,105 acute care patient admissions at a tertiary care academic medical center. We developed models to predict deterioration resulting in ICU transfer or unanticipated death within the next 24 hours using either vital signs, laboratory results, or cardiorespiratory dynamics from continuous ECG monitoring and also evaluated models using all available data sources. We calculated the predictive validity (C-statistic), the net reclassification improvement, and the probability of achieving the difference in likelihood ratio χ2 for the additional degrees of freedom. The primary outcome occurred 755 times in 586 admissions (7%). We analyzed 395 clinical deteriorations with continuous ECG data in the 24 hours prior to an event. Using only continuous ECG measures resulted in a C-statistic of 0.65, similar to models using only laboratory results and vital signs (0.63 and 0.69 respectively). Addition of continuous ECG measures to models using conventional measurements improved the C-statistic by 0.01 and 0.07; a model integrating all data sources had a C-statistic of 0.73 with categorical net reclassification improvement of 0.09 for a change of 1 decile in risk. The difference in likelihood ratio χ2 between integrated models with and without cardiorespiratory dynamics was 2158 (p value: <0.001). Cardiorespiratory dynamics from continuous ECG monitoring detect clinical deterioration in acute care patients and improve performance of conventional models that use only laboratory results and vital signs.

  3. Fuzzy classifier based support vector regression framework for Poisson ratio determination

    NASA Astrophysics Data System (ADS)

    Asoodeh, Mojtaba; Bagheripour, Parisa

    2013-09-01

    Poisson ratio is considered as one of the most important rock mechanical properties of hydrocarbon reservoirs. Determination of this parameter through laboratory measurement is time, cost, and labor intensive. Furthermore, laboratory measurements do not provide continuous data along the reservoir intervals. Hence, a fast, accurate, and inexpensive way of determining Poisson ratio which produces continuous data over the whole reservoir interval is desirable. For this purpose, support vector regression (SVR) method based on statistical learning theory (SLT) was employed as a supervised learning algorithm to estimate Poisson ratio from conventional well log data. SVR is capable of accurately extracting the implicit knowledge contained in conventional well logs and converting the gained knowledge into Poisson ratio data. Structural risk minimization (SRM) principle which is embedded in the SVR structure in addition to empirical risk minimization (EMR) principle provides a robust model for finding quantitative formulation between conventional well log data and Poisson ratio. Although satisfying results were obtained from an individual SVR model, it had flaws of overestimation in low Poisson ratios and underestimation in high Poisson ratios. These errors were eliminated through implementation of fuzzy classifier based SVR (FCBSVR). The FCBSVR significantly improved accuracy of the final prediction. This strategy was successfully applied to data from carbonate reservoir rocks of an Iranian Oil Field. Results indicated that SVR predicted Poisson ratio values are in good agreement with measured values.

  4. Efficacy and safety of a 14-day administration of tolvaptan in the treatment of patients with ascites in hepatic oedema.

    PubMed

    Sakaida, Isao; Yamashita, Satoyoshi; Kobayashi, Tomoo; Komatsu, Masafumi; Sakai, Terufumi; Komorizono, Yasuji; Okada, Mitsuru; Okita, Kiwamu

    2013-06-01

    To investigate the efficacy and safety of 14 days' orally administered tolvaptan as adjunctive treatment for hepatic oedema in Japanese liver cirrhosis patients with insufficient response to conventional diuretics, with the option to increase dose in those who did not respond initially. This multicentre, single-arm, phase 3 study allocated patients with liver cirrhosis and persistent ascites to 7-day treatment with 7.5 mg/day tolvaptan followed by an additional 7 days' treatment. Responders at day 7 (achieving ≥ 1 kg body-weight reduction) continued on 7.5 mg/day tolvaptan; nonresponders (<1 kg body-weight reduction) received 15 mg/day tolvaptan. Conventional diuretic treatment continued throughout. The primary endpoint was change in body weight from baseline, as a marker of ascites volume. A total of 51 patients received 7.5 mg/day tolvaptan for 7 days, which caused a significant reduction in mean body weight (55% response rate). During the second 7-day treatment period, 30 patients received 7.5 mg/day tolvaptan and 13 patients received tolvaptan 15 mg/day: response rates were 43% and 23%, respectively. Two serious adverse events were observed. Serum sodium was within normal range. Tolvaptan therapy for 14 days (with possible dose increase as necessary), in combination with conventional diuretics, effectively reduced body weight in patients with hepatic oedema.

  5. Does vascular stapling improve compliance of vascular anastomoses?

    PubMed

    Stansby, G; Knez, P; Berwanger, C S; Nelson, K; Reichert, V; Schmitz-Rixen, T

    2001-01-01

    Elastic properties of vessel walls are altered by vascular anastomoses. Such alterations may lead to neointimal hyperplasia, which is a common cause of reocclusion following vascular surgery. The severity of paraanastomotic hypercompliant zones and anastomotic compliance drop depend on suturing material and on elastic properties of the anastomotic vessel segments. This study compares paraanastomotic hypercompliance and anastomotic compliance drop when using a new vascular closure system (VCS) and a conventional, continuous suture line in the preparation of end-to-end anastomoses. Compliance of artery-artery, vein-artery, and polytetrafluoroethylene-artery anastomoses was measured in an artificial circulation system at mean pressures of 60, 90, and 120 mm Hg, comparing conventional suturing and the VCS. When using the VCS for vein-artery anastomoses, significantly less postanastomotic hypercompliance was achieved at mean pressures of 60 mm Hg (14.2 +/-3.8% above remote postanastomotic area), compared to suture (55.1 +/-14.8%, p<0.05). At 90 mm Hg, respective values were 11.0 +/-2.3% for VCS and 54.7 +/-10.1% for suture, p<0.01. At 120 mm Hg, in polytetrafluoroethylene-artery anastomoses, the anastomotic compliance drop was significantly less when using the continuous suture line (93.9 +/-1.1% below remote postanastomotic compliance), compared to VCS (97.2 +/-0.2%, p<0.05). Compared to conventional suturing, use of the VCS reduced postanastomotic hypercompliance in vein-artery anastomoses.

  6. The evolution of ambulatory ECG monitoring.

    PubMed

    Kennedy, Harold L

    2013-01-01

    Ambulatory Holter electrocardiographic (ECG) monitoring has undergone continuous technological evolution since its invention and development in the 1950s era. With commercial introduction in 1963, there has been an evolution of Holter recorders from 1 channel to 12 channel recorders with increasingly smaller storage media, and there has evolved Holter analysis systems employing increasingly technologically advanced electronics providing a myriad of data displays. This evolution of smaller physical instruments with increasing technological capacity has characterized the development of electronics over the past 50 years. Currently the technology has been focused upon the conventional continuous 24 to 48 hour ambulatory ECG examination, and conventional extended ambulatory monitoring strategies for infrequent to rare arrhythmic events. However, the emergence of the Internet, Wi-Fi, cellular networks, and broad-band transmission has positioned these modalities at the doorway of the digital world. This has led to an adoption of more cost-effective strategies to these conventional methods of performing the examination. As a result, the emergence of the mobile smartphone coupled with this digital capacity is leading to the recent development of Holter smartphone applications. The potential of point-of-care applications utilizing the Holter smartphone and a vast array of new non-invasive sensors is evident in the not too distant future. The Holter smartphone is anticipated to contribute significantly in the future to the field of global health. © 2013.

  7. 40 CFR 423.14 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... control technology (BCT). [Reserved] 423.14 Section 423.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS STEAM ELECTRIC POWER GENERATING POINT SOURCE... by the application of the best conventional pollutant control technology (BCT). [Reserved] ...

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amano, Yasuo; Gemma, Kazuhito; Kawamata, Hiroshi

    Fat-suppressed, three-dimensional magnetic resonance angiography (3D MRA) was performed on nine patients with 11 iliac artery stenoses following atherectomy or stent placement. The MRA accurately depicted continued patency, restenosis, or aneurysm formation when compared with immediate posttreatment conventional arteriography. Therefore MRA is accurate and can be used independently for clinical decision making.

  9. An economical method for the continuous production of iodine-123

    NASA Technical Reports Server (NTRS)

    Blue, J. W.; Smith, W. R.; Sodd, V. J.

    1968-01-01

    Simple and inexpensive method produces iodine 123, in a conventional cyclotron. Tellurium 122, a stable isotope available in enrichments exceeding 95 percent, is held on a porous metal plate by a flowing stream of helium and bombarded with either alpha particles or helium 3.

  10. 15 CFR 712.2 - Restrictions on activities involving Schedule 1 chemicals.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Schedule 1 chemicals. 712.2 Section 712.2 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING SCHEDULE 1 CHEMICALS § 712.2 Restrictions on activities involving...

  11. The potential contribution of biodiesel with improved properties to an alternative energy mix

    USDA-ARS?s Scientific Manuscript database

    Continuing and increasing world-wide concerns regarding the availability of petroleum and other "conventional" sources of energy have sparked the search for sustainable sources of energy. Fuels derived from renewable biological sources (biomass) play a prominent role among the sustainable energy so...

  12. 40 CFR 429.52 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology (BCT). [Reserved] 429.52 Section 429.52 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Dry Process... by the application of the best conventional pollutant control technology (BCT). [Reserved] ...

  13. Understanding the role of ORF-C gene in the pathogenicity of infectious laryngotracheitis virus

    USDA-ARS?s Scientific Manuscript database

    Infectious laryngotracheitis (ILT) is a very serious and widespread respiratory disease of chickens caused by infectious laryngotracheitis virus (ILTV). Conventional attenuated ILT vaccines, obtained by continuous passages in chicken embryos and tissue culture, had been the main tools utilized by th...

  14. 15 CFR 712.2 - Restrictions on activities involving Schedule 1 chemicals.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Schedule 1 chemicals. 712.2 Section 712.2 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING SCHEDULE 1 CHEMICALS § 712.2 Restrictions on activities involving...

  15. 40 CFR 424.67 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... control technology. 424.67 Section 424.67 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERROALLOY MANUFACTURING POINT SOURCE CATEGORY Electrolytic... reduction attainable by the application of the best conventional pollutant control technology. Except as...

  16. 40 CFR 424.77 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... control technology. 424.77 Section 424.77 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERROALLOY MANUFACTURING POINT SOURCE CATEGORY Electrolytic... attainable by the application of the best conventional pollutant control technology. Except as provided in...

  17. 40 CFR 424.37 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... control technology. 424.37 Section 424.37 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERROALLOY MANUFACTURING POINT SOURCE CATEGORY Slag Processing... by the application of the best conventional pollutant control technology. Except as provided in...

  18. 50 CFR 23.56 - What U.S. CITES document conditions do I need to follow?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... wildlife and plants, transport conditions must comply with the International Air Transport Association Live Animals Regulations (for animals) or the International Air Transport Association Perishable Cargo..., EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN...

  19. 15 CFR 712.2 - Restrictions on activities involving Schedule 1 chemicals.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Schedule 1 chemicals. 712.2 Section 712.2 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING SCHEDULE 1 CHEMICALS § 712.2 Restrictions on activities involving...

  20. 50 CFR 23.51 - What are the requirements for issuing a partially completed CITES document?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... captivity or artificially propagated. (D) Appendix-I specimens from registered commercial breeding operations. (E) Appendix-I plants artificially propagated for commercial purposes. (F) Other specimens that..., BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE...

  1. 50 CFR 23.51 - What are the requirements for issuing a partially completed CITES document?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... captivity or artificially propagated. (D) Appendix-I specimens from registered commercial breeding operations. (E) Appendix-I plants artificially propagated for commercial purposes. (F) Other specimens that..., BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE...

  2. 50 CFR 23.51 - What are the requirements for issuing a partially completed CITES document?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... captivity or artificially propagated. (D) Appendix-I specimens from registered commercial breeding operations. (E) Appendix-I plants artificially propagated for commercial purposes. (F) Other specimens that..., BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE...

  3. 50 CFR 23.51 - What are the requirements for issuing a partially completed CITES document?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... captivity or artificially propagated. (D) Appendix-I specimens from registered commercial breeding operations. (E) Appendix-I plants artificially propagated for commercial purposes. (F) Other specimens that..., BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE...

  4. 50 CFR 23.51 - What are the requirements for issuing a partially completed CITES document?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... captivity or artificially propagated. (D) Appendix-I specimens from registered commercial breeding operations. (E) Appendix-I plants artificially propagated for commercial purposes. (F) Other specimens that..., BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE...

  5. Bridging conventional and molecular genetics of sorghum insect resistance

    USDA-ARS?s Scientific Manuscript database

    Sustainable production of sorghum, Sorghum bicolor (L.) Moench, depends on effective control of insect pests as they continue to compete with humans for the sorghum crop. Insect pests are major constraint in sorghum production, and nearly 150 insect species are serious pests of this crop worldwide,...

  6. 40 CFR 455.63 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... control technology (BCT). 455.63 Section 455.63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS PESTICIDE CHEMICALS Repackaging of Agricultural Pesticides... effluent reduction attainable by the application of the best conventional pollutant control technology (BCT...

  7. Conversion of agricultural residues to carboxymethylcellulose and carboxymethylcellulose acetate

    USDA-ARS?s Scientific Manuscript database

    In view of continuing interest in the use of agricultural by-products, we have converted cellulose, wheat straw, barley straw, and rice hull into carboxymethylcellulose (CMC). Microwave-assisted synthesis was found to be a partly effective alternative to the conventional heating process. The CMC thu...

  8. 21 CFR 186.1673 - Pulp.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... food packaging containers. (c) The ingredient is used in paper and paperboard made by conventional... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Pulp. 186.1673 Section 186.1673 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) INDIRECT FOOD...

  9. The role of integrative, whole organism testing in monitoring applications: Back to the future

    EPA Science Inventory

    The biological effects of chemicals released to surface waters continue to be an area of uncertainty in risk assessment and risk management. Based on conventional risk assessment considerations, adequate exposure and effects information are required to reach a scientifically soun...

  10. 26 CFR 521.112 - Compensation for labor or personal services.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 19 2010-04-01 2010-04-01 false Compensation for labor or personal services. 521.112 Section 521.112 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS DENMARK General Income Tax Taxation of Nonresident Aliens Who...

  11. 26 CFR 521.109 - Real property income, natural resource royalties.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 19 2010-04-01 2010-04-01 false Real property income, natural resource royalties. 521.109 Section 521.109 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS DENMARK General Income Tax Taxation of Nonresident Aliens Who...

  12. Mendel’s legacy lives through management of sugarcane pests

    USDA-ARS?s Scientific Manuscript database

    Entomology and classical Mendelian genetics have had a long association and Mendel’s legacy continues to live through sugarcane pests. In this paper, we discuss examples of that legacy as applied to conventional and molecular approaches to breeding for insect resistance. We also discuss the applicat...

  13. 40 CFR 423.14 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... control technology (BCT). [Reserved] 423.14 Section 423.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS STEAM ELECTRIC POWER GENERATING POINT SOURCE... by the application of the best conventional pollutant control technology (BCT). [Reserved] ...

  14. 40 CFR 423.14 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... control technology (BCT). [Reserved] 423.14 Section 423.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS STEAM ELECTRIC POWER GENERATING POINT SOURCE... by the application of the best conventional pollutant control technology (BCT). [Reserved] ...

  15. 40 CFR 423.14 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... control technology (BCT). [Reserved] 423.14 Section 423.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS STEAM ELECTRIC POWER GENERATING POINT SOURCE... by the application of the best conventional pollutant control technology (BCT). [Reserved] ...

  16. 40 CFR 423.14 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... control technology (BCT). [Reserved] 423.14 Section 423.14 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS STEAM ELECTRIC POWER GENERATING POINT SOURCE... by the application of the best conventional pollutant control technology (BCT). [Reserved] ...

  17. The World According to Women.

    ERIC Educational Resources Information Center

    Eddy, David, Ed.; Garb, Gill, Ed.

    1987-01-01

    This issue of Reports Magazine focuses on the challenges that women face and their efforts to continue the struggle for a wider recognition in development and all other spheres of life. "Feminist Issues in Development" (Peggy Antrobus) discusses how feminist analyses offer critiques of conventional approaches to development that…

  18. 15 CFR 720.4 - Effect of denial.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Effect of denial. 720.4 Section 720.4 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS DENIAL OF EXPORT...

  19. 15 CFR 719.3 - Violations of the IEEPA subject to judicial enforcement proceedings.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ENFORCEMENT § 719.3 Violations of the IEEPA subject to judicial enforcement proceedings. (a) Violations—(1) Import restrictions involving Schedule 1 chemicals. Except as otherwise...

  20. 15 CFR 719.5 - Initiation of administrative proceedings.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Initiation of administrative proceedings. 719.5 Section 719.5 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  1. 15 CFR 719.9 - Summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Summary decision. 719.9 Section 719.9 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ENFORCEMENT § 719.9...

  2. 15 CFR 719.21 - Payment of final assessment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Payment of final assessment. 719.21 Section 719.21 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  3. 15 CFR 719.9 - Summary decision.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Summary decision. 719.9 Section 719.9 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ENFORCEMENT § 719.9...

  4. 15 CFR 720.4 - Effect of denial.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Effect of denial. 720.4 Section 720.4 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS DENIAL OF EXPORT...

  5. 15 CFR 719.5 - Initiation of administrative proceedings.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Initiation of administrative proceedings. 719.5 Section 719.5 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  6. 15 CFR 719.3 - Violations of the IEEPA subject to judicial enforcement proceedings.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ENFORCEMENT § 719.3 Violations of the IEEPA subject to judicial enforcement proceedings. (a) Violations—(1) Import restrictions involving Schedule 1 chemicals. Except as otherwise...

  7. 15 CFR 719.21 - Payment of final assessment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Payment of final assessment. 719.21 Section 719.21 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  8. 46 CFR 189.60-1 - Application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Application. 189.60-1 Section 189.60-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS INSPECTION AND CERTIFICATION Certificates Under International Convention for Safety of Life at Sea, 1974 § 189.60-1 Application...

  9. Force characteristics in continuous path controlled crankpin grinding

    NASA Astrophysics Data System (ADS)

    Zhang, Manchao; Yao, Zhenqiang

    2015-03-01

    Recent research on the grinding force involved in cylindrical plunge grinding has focused mainly on steady-state conditions. Unlike in conventional external cylindrical plunge grinding, the conditions between the grinding wheel and the crankpin change periodically in path controlled grinding because of the eccentricity of the crankpin and the constant rotational speed of the crankshaft. The objective of this study is to investigate the effects of various grinding conditions on the characteristics of the grinding force during continuous path controlled grinding. Path controlled plunge grinding is conducted at a constant rotational speed using a cubic boron nitride (CBN) wheel. The grinding force is determined by measuring the torque. The experimental results show that the force and torque vary sinusoidally during dry grinding and load grinding. The variations in the results reveal that the resultant grinding force and torque decrease with higher grinding speeds and increase with higher peripheral speeds of the pin and higher grinding depths. In path controlled grinding, unlike in conventional external cylindrical plunge grinding, the axial grinding force cannot be disregarded. The speeds and speed ratios of the workpiece and wheel are also analyzed, and the analysis results show that up-grinding and down-grinding occur during the grinding process. This paper proposes a method for describing the force behavior under varied process conditions during continuous path controlled grinding, which provides a beneficial reference for describing the material removal mechanism and for optimizing continuous controlled crankpin grinding.

  10. Geopotential Field Anomaly Continuation with Multi-Altitude Observations

    NASA Technical Reports Server (NTRS)

    Kim, Jeong Woo; Kim, Hyung Rae; von Frese, Ralph; Taylor, Patrick; Rangelova, Elena

    2012-01-01

    Conventional gravity and magnetic anomaly continuation invokes the standard Poisson boundary condition of a zero anomaly at an infinite vertical distance from the observation surface. This simple continuation is limited, however, where multiple altitude slices of the anomaly field have been observed. Increasingly, areas are becoming available constrained by multiple boundary conditions from surface, airborne, and satellite surveys. This paper describes the implementation of continuation with multi-altitude boundary conditions in Cartesian and spherical coordinates and investigates the advantages and limitations of these applications. Continuations by EPS (Equivalent Point Source) inversion and the FT (Fourier Transform), as well as by SCHA (Spherical Cap Harmonic Analysis) are considered. These methods were selected because they are especially well suited for analyzing multi-altitude data over finite patches of the earth such as covered by the ADMAP database. In general, continuations constrained by multi-altitude data surfaces are invariably superior to those constrained by a single altitude data surface due to anomaly measurement errors and the non-uniqueness of continuation.

  11. Geopotential Field Anomaly Continuation with Multi-Altitude Observations

    NASA Technical Reports Server (NTRS)

    Kim, Jeong Woo; Kim, Hyung Rae; vonFrese, Ralph; Taylor, Patrick; Rangelova, Elena

    2011-01-01

    Conventional gravity and magnetic anomaly continuation invokes the standard Poisson boundary condition of a zero anomaly at an infinite vertical distance from the observation surface. This simple continuation is limited, however, where multiple altitude slices of the anomaly field have been observed. Increasingly, areas are becoming available constrained by multiple boundary conditions from surface, airborne, and satellite surveys. This paper describes the implementation of continuation with multi-altitude boundary conditions in Cartesian and spherical coordinates and investigates the advantages and limitations of these applications. Continuations by EPS (Equivalent Point Source) inversion and the FT (Fourier Transform), as well as by SCHA (Spherical Cap Harmonic Analysis) are considered. These methods were selected because they are especially well suited for analyzing multi-altitude data over finite patches of the earth such as covered by the ADMAP database. In general, continuations constrained by multi-altitude data surfaces are invariably superior to those constrained by a single altitude data surface due to anomaly measurement errors and the non-uniqueness of continuation.

  12. Prevalence, Treatment, and Control Rates of Conventional and Ambulatory Hypertension Across 10 Populations in 3 Continents.

    PubMed

    Melgarejo, Jesus D; Maestre, Gladys E; Thijs, Lutgarde; Asayama, Kei; Boggia, José; Casiglia, Edoardo; Hansen, Tine W; Imai, Yutaka; Jacobs, Lotte; Jeppesen, Jørgen; Kawecka-Jaszcz, Kalina; Kuznetsova, Tatiana; Li, Yan; Malyutina, Sofia; Nikitin, Yuri; Ohkubo, Takayoshi; Stolarz-Skrzypek, Katarzyna; Wang, Ji-Guang; Staessen, Jan A

    2017-07-01

    Hypertension is a major global health problem, but prevalence rates vary widely among regions. To determine prevalence, treatment, and control rates of hypertension, we measured conventional blood pressure (BP) and 24-hour ambulatory BP in 6546 subjects, aged 40 to 79 years, recruited from 10 community-dwelling cohorts on 3 continents. We determined how between-cohort differences in risk factors and socioeconomic factors influence hypertension rates. The overall prevalence was 49.3% (range between cohorts, 40.0%-86.8%) for conventional hypertension (conventional BP ≥140/90 mm Hg) and 48.7% (35.2%-66.5%) for ambulatory hypertension (ambulatory BP ≥130/80 mm Hg). Treatment and control rates for conventional hypertension were 48.0% (33.5%-74.1%) and 38.6% (10.1%-55.3%) respectively. The corresponding rates for ambulatory hypertension were 48.6% (30.5%-71.9%) and 45.6% (18.6%-64.2%). Among 1677 untreated subjects with conventional hypertension, 35.7% had white coat hypertension (23.5%-56.2%). Masked hypertension (conventional BP <140/90 mm Hg and ambulatory BP ≥130/80 mm Hg) occurred in 16.9% (8.8%-30.5%) of 3320 untreated subjects who were normotensive on conventional measurement. Exclusion of participants with diabetes mellitus, obesity, hypercholesterolemia, or history of cardiovascular complications resulted in a <9% reduction in the conventional and 24-hour ambulatory hypertension rates. Higher social and economic development, measured by the Human Development Index, was associated with lower rates of conventional and ambulatory hypertension. In conclusion, high rates of hypertension in all cohorts examined demonstrate the need for improvements in prevention, treatment, and control. Strategies for the management of hypertension should continue to not only focus on preventable and modifiable risk factors but also consider societal issues. © 2017 American Heart Association, Inc.

  13. Removal of endocrine-disrupting chemicals and conventional pollutants in a continuous-operating activated sludge process integrated with ozonation for excess sludge reduction.

    PubMed

    Nie, Yafeng; Qiang, Zhimin; Ben, Weiwei; Liu, Junxin

    2014-06-01

    Sludge ozonation is considered as a promising technology to achieve a complete reduction of excess sludge, but as yet its effects on the removal of endocrine-disrupting chemicals (EDCs) and conventional pollutants (i.e., COD, N and P) in the activated sludge process are still unclear. In this study, two lab-scale continuous-operating activated sludge treatment systems were established: one was operated in conjunction with ozonation for excess sludge reduction, and the other was operated under normal conditions as control. The results indicate that an ozone dose of 100 mg O₃ g(-1)SS led to a zero yield of excess sludge in the sludge-reduction system during a continuous-operating period of 45d. Although ozonation gave a relatively lower specific oxygen uptake rate of activated sludge, it had little effect on the system's removal performance of COD and nitrogen substances. As a plus, sludge ozonation contributed a little more removal of target EDCs (estrone, 17β-estrodiol, estriol, 17α-ethinylestradiol, bisphenol A, and 4-nonylphenol). However, the total phosphorus removal declined notably due to its accumulation in the sludge-reduction system, which necessitates phosphorus recovery for the activated sludge process. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Improving the performance of immobilized β-glucosidase using a microreactor.

    PubMed

    Wei, Ce; Zhou, Yan; Zhuang, Wei; Li, Ganlu; Jiang, Min; Zhang, Hongman

    2018-04-01

    Here, we have presented a technically simple and efficient method for preparing a continuous flow microreactor by employing immobilized β-glucosidase in a silica quartz capillary tube. Developing an immobilized enzyme layer on the inner wall of the capillary tube involved the modification of the inner wall using bifunctional crosslinking agents 3-aminopropyltriethoxysilane and glutaraldehyde before attaching β-glucosidase. The microreactor afforded unique reaction capacities compared with conventional batch operational configurations. These included enhanced pH and thermal stability during storage tests, increased conversion rates of cellobiose, and reduced product inhibition. The maximum conversion rate of soluble substrate cellobiose digestion in the microreactor was 76% at 50°C and pH 4.8 when the microreactor was operated continually over 10 h at a flow rate of 7 μL/min. This was markedly contrasting to the observed conversion rate of 56% when cellobiose was digested in a conventional batch mode under the same pH and temperature conditions. Reaction inhibition by glucose was significantly reduced in the microreactor. We postulate that the increased capacity of glucose to diffuse into the continual flowing media above the immobilized enzyme layer prevents glucose from reaching inhibitory concentrations at the substrate-enzyme interface. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  15. Energy efficient fluorescent ballasts. Phase I, final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stevens Luminoptics Corporation

    1978-06-21

    The development of a high-frequency electronic (Stevens) ballast for fluorescent lamps is described. It is claimed that use of this ballast could reduce use energy consumption by 1.2 to 2.5 percent. The Stevens ballast has a basic efficiency of 29 percent when used with conventional lamps. With the more efficient lamps, the efficiency increases drastically. The conventional ballast and lamp has an efficiacy of approximately 60 to 63 lumens per watt (LPW). With the Stevens ballast the efficiacy raises to between 75 and 80 lumens per watt. When the Stevens ballast is utilized with the newer high efficiency lamps themore » efficiacy increases to 90 to 95 lumens per watt or a full 51 percent improvement over conventional coil and core ballasts and 25 percent over the best high efficiency premium coil and core ballasts. In addition to its energy savings capabilities, this high frequency fluorescent lamp ballast has the advantages that it is a true retrofit device that is directly interchangeable with the conventional coil core ballast, and it is dimmable over a wide and continuous range. (LCLC)« less

  16. Comparison of surgically induced astigmatism in patients with horizontal rectus muscle recession

    PubMed Central

    Çakmak, Harun; Kocatürk, Tolga; Dündar, Sema Oruç

    2014-01-01

    AIM To compare surgically induced astigmatism (SIA) following horizontal rectus muscle recession surgery between suspension recession with both the “hang-back” technique and conventional recession technique. METHODS Totally, 48 eyes of 24 patients who had undergone horizontal rectus muscle recession surgery were reviewed retrospectively. The patients were divided into two groups. Twelve patients were operated on by the hang-back technique (Group 1), and 12 by the conventional recession technique (Group 2). SIA was calculated on the 1st wk, 1st and in the 3rd mo after surgery using the SIA calculator. RESULTS SIA was statistically higher in the Group 1 all postoperative follow-up. SIA was the highest in the 1st wk, and decreased gradually in both groups. CONCLUSION The suspension recession technique induced much more SIA than the conventional recession technique. This difference also continued in the following visits. Therefore, the refractive power should be checked postoperatively in order to avoid refractive amblyopia. Conventional recession surgery should be the preferred method so as to minimize the postoperative refractive changes in patients with amblyopia. PMID:25161948

  17. Global prediction of continuous hydrocarbon accumulations in self-sourced reservoirs

    USGS Publications Warehouse

    Eoff, Jennifer D.

    2012-01-01

    This report was first presented as an abstract in poster format at the American Association of Petroleum Geologists (AAPG) 2012 Annual Convention and Exhibition, April 22-25, Long Beach, Calif., as Search and Discovery Article no. 90142. Shale resource plays occur in predictable tectonic settings within similar orders of magnitude of eustatic events. A conceptual model for predicting the presence of resource-quality shales is essential for evaluating components of continuous petroleum systems. Basin geometry often distinguishes self-sourced resource plays from conventional plays. Intracratonic or intrashelf foreland basins at active margins are the predominant depositional settings among those explored for the development of self-sourced continuous accumulations, whereas source rocks associated with conventional accumulations typically were deposited in rifted passive margin settings (or other cratonic environments). Generally, the former are associated with the assembly of supercontinents, and the latter often resulted during or subsequent to the breakup of landmasses. Spreading rates, climate, and eustasy are influenced by these global tectonic events, such that deposition of self-sourced reservoirs occurred during periods characterized by rapid plate reconfiguration, predominantly greenhouse climate conditions, and in areas adjacent to extensive carbonate sedimentation. Combined tectonic histories, eustatic curves, and paleogeographic reconstructions may be useful in global predictions of organic-rich shale accumulations suitable for continuous resource development. Accumulation of marine organic material is attributed to upwellings that enhance productivity and oxygen-minimum bottom waters that prevent destruction of organic matter. The accumulation of potential self-sourced resources can be attributed to slow sedimentation rates in rapidly subsiding (incipient, flexural) foreland basins, while flooding of adjacent carbonate platforms and other cratonic highs occurred. In contrast, deposition of this resource type on rifted passive margins was likely the result of reactivation of long-lived cratonic features or salt tectonic regimes that created semi-confined basins. Commonly, loading by thick sections of clastic material, following thermal relaxation after plate collision or rift phases, advances kerogen maturation. With few exceptions, North American self-sourced reservoirs appear to be associated with calcitic seas and predominantly greenhouse or transitional ("warm" to "cool") global climatic conditions. Significant changes to the global carbon budget may also be a contributing factor in the stratigraphic distribution of continuous resource plays, requiring additional evaluation.

  18. Thin film DNA-complex-based dye lasers fabricated by immersion and conventional processes

    NASA Astrophysics Data System (ADS)

    Kawabe, Yutaka; Suzuki, Yuki

    2017-08-01

    DNA based thin film dye laser is one of promising optical devices for future technology. Laser oscillation and amplified spontaneous emission (ASE) were demonstrated by hemicyanine-doped DNA complex films prepared with `immersion method' as well as those made by a conventional way. In the immersion process, DNA-surfactant complex films were stained by immersion into an acetone solution including the dyes. In this study, three types of hemicyanines were incorporated with both methods, and laser oscillation was achieved with optically induced population grating formed in all of the complex films. The laser threshold values for six cases ranged in 0.07 - 0.18 mJ/cm2 , which was close to the best values made in DNA complex matrices. Continual pumping showed that laser oscillation persisted for 4 - 10 minutes. Immersion process gave superior laser capability especially for output efficiency over the conventional counterparts.

  19. Comparison of thin-film resistance heat-transfer gages with thin-skin transient calorimeter gages in conventional hypersonic wind tunnels

    NASA Technical Reports Server (NTRS)

    Miller, C. G., III

    1981-01-01

    Thin film gages deposited at the stagnation region of small (8.1-mm-diameter) hemispheres and gages mounted flush with the surface of a sharp-leading-edge flat plate were tested in the Langley continuous-flow hypersonic tunnel and in the Langley hypersonic CF4 tunnel. Two substrate materials were tested, quartz and a machinable glass-ceramic. Small hemispheres were also tested utilizing the thin-skin transient calorimeter technique usually employed in conventional tunnels. One transient calorimeter model was a thin shell of stainless steel, and the other was a thin-skin insert of stainless steel mounted into a hemisphere fabricated from a machinable-glass-ceramic. Measured heat-transfer rates from the various hemispheres were compared with one another and with predicted rates. The results demonstrate the feasibility and advantages of using-film resistance heat-transfer gages in conventional hypersonic wind tunnels over a wide range of conditions.

  20. Design, construction, testing and evaluation of a residential ice storage air conditioning system

    NASA Astrophysics Data System (ADS)

    Santos, J. J.; Ritz, T. A.

    1982-12-01

    The experimental system was used to supply cooling to a single wide trailer and performance data were compared to a conventional air conditioning system of the some capacity. Utility rate information was collected from over one hundred major utility companies and used to evaluate economic comparison of the two systems. The ice storage system utilized reduced rate time periods to accommodate ice while providing continuous cooling to the trailer. The economic evaluation resulted in finding that the ice storage system required over 50% more energy than the conventional system. Although a few of the utility companies offered rate structures which would result in savings of up to $200 per year, this would not be enough to offset higher initial costs over the life of the storage system. Recommendations include items that would have to be met in order for an ice storage system to be an economically viable alternative to the conventional system.

  1. Nutritive and health-promoting value of organic vegetables.

    PubMed

    Sobieralski, Krzysztof; Siwulski, Marek; Sas-Golak, Iwona

    2013-01-01

    In recent years in Poland we may observe a considerable development of organic vegetable production. Increased interest in organic products results from an opinion of the consumers on their high quality and health safety. However, results of research comparing nutritive value and contents of biologically active compounds in vegetables from organic and conventional farms are ambiguous. Most studies confirm higher contents of certain vitamins and antioxidants in organic vegetables, as well as their lower contents of nitrates and pesticide residue in comparison to vegetables grown in the conventional manner. There are also reports which did not confirm such differences or showed opposite trends. Research results at present do not make it possible to formulate a general conclusion on a higher health-promoting value of organic vegetables in comparison to those grown by conventional farming methods. It is necessary to continue research in order to explain the effect of organic raw materials on human health in a more comprehensive manner.

  2. Utility of Functional Hemodynamics and Echocardiography to Aid Diagnosis and Management of Shock.

    PubMed

    McGee, William T; Raghunathan, Karthik; Adler, Adam C

    2015-12-01

    The utility of functional hemodynamics and bedside ultrasonography is increasingly recognized as advantageous for both improved diagnosis and management of shock states. In contrast to conventional "static" measures, "dynamic" hemodynamic measures and bedside imaging modalities enhance pathophysiology-based comprehensive understanding of shock states and the response to therapy. The current editions of major textbooks in the primary specialties--in which clinicians routinely encounter patients in shock--including surgery, anesthesia, emergency medicine, and internal medicine continue to incorporate traditional (conventional) descriptions of shock that use well-described (but potentially misleading) intravascular pressures to classify shock states. Reliance on such intravascular pressure measurements is not as helpful as newer "dynamic" functional measures including ultrasonography to both better assess volume responsiveness and biventricular cardiac function. This review thus emphasizes the application of current functional hemodynamics and ultrasonography to the diagnosis and management of shock as a contrast to conventional "static" pressure-based measures.

  3. H2S and polysulfide metabolism: Conventional and unconventional pathways.

    PubMed

    Olson, Kenneth R

    2018-03-01

    It is now well established that hydrogen sulfide (H 2 S) is an effector of a wide variety of physiological processes. It is also clear that many of the effects of H 2 S are mediated through reactions with cysteine sulfur on regulatory proteins and most of these are not mediated directly by H 2 S but require prior oxidation of H 2 S and the formation of per- and polysulfides (H 2 S n , n = 2-8). Attendant with understanding the regulatory functions of H 2 S and H 2 S n is an appreciation of the mechanisms that control, i.e., both increase and decrease, their production and catabolism. Although a number of standard "conventional" pathways have been described and well characterized, novel "unconventional" pathways are continuously being identified. This review summarizes our current knowledge of both the conventional and unconventional. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. 40 CFR 424.27 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... control technology. 424.27 Section 424.27 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS FERROALLOY MANUFACTURING POINT SOURCE CATEGORY Covered Electric... conventional pollutant control technology. Except as provided in §§ 125.30 through 125.32, any existing point...

  5. 40 CFR 469.19 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology (BCT). 469.19 Section 469.19 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ELECTRICAL AND ELECTRONIC COMPONENTS POINT SOURCE CATEGORY Semiconductor... application of the best conventional pollution control technology (BCT). Except as provided in 40 CFR 125.30...

  6. 40 CFR 469.29 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... technology (BCT). 469.29 Section 469.29 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ELECTRICAL AND ELECTRONIC COMPONENTS POINT SOURCE CATEGORY Electronic... by the application of the best conventional pollution control technology (BCT). Except as provided in...

  7. 26 CFR 1.894-1 - Income affected by treaty.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX... States $60,000 in service fees through the operation of business A and $10,000 in dividends through the... corporation. The service fees are considered to be industrial or commercial profits under the tax convention...

  8. 26 CFR 1.894-1 - Income affected by treaty.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX... States $60,000 in service fees through the operation of business A and $10,000 in dividends through the... corporation. The service fees are considered to be industrial or commercial profits under the tax convention...

  9. Continuous sawmill studies: protocols, practices, and profits

    Treesearch

    Robert Mayer; Jan Wiedenbeck

    2005-01-01

    In today's global economy, the "opportunity cost" associated with suboptimal utilization of raw material and mill resources is significant. As a result, understanding the profit potential associated with different types of logs is critically important for sawmill survival. The conventional sawmill study typically has been conducted on a substantially...

  10. 50 CFR 23.49 - What are the requirements for an exhibition traveling internationally?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE.... Article VII(7) of the Treaty grants an exemption for specimens that qualify as bred in captivity... wildlife and plants, or their parts, products, or derivatives in an exhibition that travels internationally...

  11. 50 CFR 23.49 - What are the requirements for an exhibition traveling internationally?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE.... Article VII(7) of the Treaty grants an exemption for specimens that qualify as bred in captivity... wildlife and plants, or their parts, products, or derivatives in an exhibition that travels internationally...

  12. Can Pesticide Delivery Methods Play a Role in Sustainable Pest Management?

    USDA-ARS?s Scientific Manuscript database

    Conventional insecticides continue to play an important role in greenhouse pest management programs. Penetrating a dense plant canopy can be difficult with a handgun, and there is some evidence that boom sprayers or broadcast applications result in a more uniform deposition than handguns. A large-...

  13. 36 CFR 73.13 - Protection of U.S. World Heritage properties.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... source of funding and appropriate management framework, in the event of any proposed sale, succession...) Requirements. (1) Article 5 of the Convention mandates that each participating nation shall take, insofar as... management plans, that would ensure continued satisfactory maintenance of the property and its environment...

  14. Recent Trends in Multiple Authorship in Psychology.

    ERIC Educational Resources Information Center

    Mendenhall, Mark; Higbee, Kenneth L.

    Research in the late 1950's showed a trend towards increased multiple authorship, as opposed to single authorship, of research papers in psychology. To investigate whether the trend has continued into the 1980's, convention papers presented at the meetings of seven psychological associations and articles published in nine American Psychological…

  15. 15 CFR 713.7 - Deadlines for submission of Schedule 2 declarations, reports, and amendments.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING SCHEDULE 2 CHEMICALS § 713.7 Deadlines for submission... (production, processing, or consumption of Schedule 2 chemicals during the previous calendar year); (b) Annual...

  16. 15 CFR 714.6 - Deadlines for submission of Schedule 3 declarations, reports, and amendments.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING SCHEDULE 3 CHEMICALS § 714.6 Deadlines for submission... past activities (production of Schedule 3 chemicals during the previous calendar year); (b) Annual...

  17. 15 CFR 712.4 - New Schedule 1 production facility.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING SCHEDULE 1 CHEMICALS § 712.4 New Schedule 1 production facility. (a) Establishment of a...) of the CWCR, and you intend to begin production of Schedule 1 chemicals at your facility in...

  18. 15 CFR 712.9 - Deadlines for submission of Schedule 1 declarations, reports, advance notifications, and amendments.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS ACTIVITIES INVOLVING SCHEDULE 1 CHEMICALS § 712.9... notifications, and amendments include: (a) Annual declaration on past activities (Schedule 1 chemical production...

  19. Mind Your p's and Alphas.

    ERIC Educational Resources Information Center

    Stallings, William M.

    1985-01-01

    In the educational research literature, alpha and p are often conflated. Paradoxically, alpha retains a prominent place in textbook discussions, but it is often supplanted by p in the results sections of journal articles. Because alpha and p have unique uses, researchers should continue to employ both conventions in summarizing the outcomes of…

  20. 15 CFR Supplement No. 2 to Part 710 - Definitions of Production

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Supplement No. 2 to Part 710—Definitions of Production Schedule 1 chemicals Schedule 2 and Schedule 3... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Definitions of Production No... (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...

  1. Inclusive Leadership's Evolving Context: Organizational Climate and Culture Connect

    ERIC Educational Resources Information Center

    Dezenberg, Maria E.

    2017-01-01

    Conventional forms of leadership that are prominent in organizational life today are seemingly antithetical to the landscape of our dynamic, global society. The continued focus on traditional hierarchies with leadership that functions in a "chain of command" manner begs the question of how organizations can reshape routines and…

  2. 40 CFR 426.17 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... control technology (BCT). 426.17 Section 426.17 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GLASS MANUFACTURING POINT SOURCE CATEGORY Insulation Fiberglass... by the application of the best conventional pollutant control technology (BCT). Except as provided in...

  3. 40 CFR 411.27 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... control technology (BCT). 411.27 Section 411.27 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CEMENT MANUFACTURING POINT SOURCE CATEGORY Leaching Subcategory... application of the conventional pollutant control technology (BCT). Except as provided in §§ 125.30 through...

  4. 40 CFR 420.137 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... representing the degree of effluent reduction attainable by the application of the best control technology for... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS IRON AND STEEL MANUFACTURING POINT SOURCE CATEGORY... effluent reduction attainable by the application of the best control technology for conventional pollutants...

  5. 40 CFR 415.177 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... control technology (BCT). 415.177 Section 415.177 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS INORGANIC CHEMICALS MANUFACTURING POINT SOURCE... conventional pollutant control technology (BCT). Except as provided in 40 CFR 125.30 through 125.32, any...

  6. 40 CFR 426.67 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... control technology. 426.67 Section 426.67 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GLASS MANUFACTURING POINT SOURCE CATEGORY Automotive Glass... attainable by the application of the best conventional pollutant control technology. Except as provided in...

  7. 40 CFR 426.77 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... control technology. 426.77 Section 426.77 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GLASS MANUFACTURING POINT SOURCE CATEGORY Automotive Glass... attainable by the application of the best conventional pollutant control technology. Except as provided in...

  8. 50 CFR 23.56 - What U.S. CITES document conditions do I need to follow?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... International Air Transport Association Live Animals Regulations. (3) You must return the original CITES..., EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN..., Federal, tribal, and foreign wildlife or plant conservation laws. (2) For export and re-export of live...

  9. 50 CFR 23.56 - What U.S. CITES document conditions do I need to follow?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... International Air Transport Association Live Animals Regulations. (3) You must return the original CITES..., EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN..., Federal, tribal, and foreign wildlife or plant conservation laws. (2) For export and re-export of live...

  10. 26 CFR 513.5 - Natural resource royalties and real property rentals.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 19 2013-04-01 2010-04-01 true Natural resource royalties and real property rentals. 513.5 Section 513.5 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS IRELAND Withholding of Tax § 513.5 Natural resource royalties...

  11. 26 CFR 513.5 - Natural resource royalties and real property rentals.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 19 2012-04-01 2010-04-01 true Natural resource royalties and real property rentals. 513.5 Section 513.5 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS IRELAND Withholding of Tax § 513.5 Natural resource royalties...

  12. 26 CFR 513.5 - Natural resource royalties and real property rentals.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 19 2014-04-01 2010-04-01 true Natural resource royalties and real property rentals. 513.5 Section 513.5 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS IRELAND Withholding of Tax § 513.5 Natural resource royalties...

  13. Confidence-Based Learning CME: Overcoming Barriers in Irritable Bowel Syndrome with Constipation

    ERIC Educational Resources Information Center

    Cash, Brooks; Mitchner, Natasha A.; Ravyn, Dana

    2011-01-01

    Introduction: Performance of health care professionals depends on both medical knowledge and the certainty with which they possess it. Conventional continuing medical education interventions assess the correctness of learners' responses but do not determine the degree of confidence with which they hold incorrect information. This study describes…

  14. 50 CFR 23.3 - What other wildlife and plant regulations may apply?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 9 2012-10-01 2012-10-01 false What other wildlife and plant regulations may apply? 23.3 Section 23.3 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE..., EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN...

  15. 50 CFR 23.3 - What other wildlife and plant regulations may apply?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 8 2011-10-01 2011-10-01 false What other wildlife and plant regulations may apply? 23.3 Section 23.3 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE..., EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN...

  16. 50 CFR 23.3 - What other wildlife and plant regulations may apply?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 9 2014-10-01 2014-10-01 false What other wildlife and plant regulations may apply? 23.3 Section 23.3 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE..., EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN...

  17. 50 CFR 23.3 - What other wildlife and plant regulations may apply?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 9 2013-10-01 2013-10-01 false What other wildlife and plant regulations may apply? 23.3 Section 23.3 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE..., EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN...

  18. 50 CFR 23.3 - What other wildlife and plant regulations may apply?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false What other wildlife and plant regulations may apply? 23.3 Section 23.3 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE..., EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN...

  19. Collegiality and Performativity in a Competitive Academic Culture

    ERIC Educational Resources Information Center

    Macfarlane, Bruce

    2016-01-01

    Collegiality is one of the most symbolically significant concepts of higher education and continues to be widely espoused as a core value by members of the academic profession. However, the highly competitive and performative nature of modern higher education means that the conventional values and behaviours associated with collegiality, such as…

  20. 50 CFR 23.7 - What office do I contact for CITES information?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... registered scientific institutions and operations breeding Appendix-I wildlife for commercial purposes; and... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD...://www.fws.gov/permits (b) Scientific issues: (1) Animals and Plants Committees documents and issues (2...

  1. 50 CFR 23.26 - When is a U.S. or foreign CITES document valid?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) Registered commercial breeding operation for Appendix-I wildlife (i) The operation is included in the... document. (16) Registered commercial nursery for Appendix-I plants The operation is included in the... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD...

  2. 50 CFR 23.36 - What are the requirements for an export permit?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Ginseng Appendix-I Plants Artificially Propagated for Commercial Purposes Biological Specimens Captive... noncommercial purposes. (See § 23.46 for the export of specimens that originated at a commercial breeding... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD...

  3. 50 CFR 17.41 - Special rules-birds.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...” (bred in captivity), or “D” (bred in captivity for commercial purposes)(see 50 CFR 23.24); or (ii... PLANTS (CONTINUED) ENDANGERED AND THREATENED WILDLIFE AND PLANTS Threatened Wildlife § 17.41 Special...: (i) Captive-bred specimens: The source code on the Convention on International Trade in Endangered...

  4. 50 CFR 23.36 - What are the requirements for an export permit?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Ginseng Appendix-I Plants Artificially Propagated for Commercial Purposes Biological Specimens Captive... noncommercial purposes. (See § 23.46 for the export of specimens that originated at a commercial breeding... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD...

  5. 50 CFR 23.7 - What office do I contact for CITES information?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... registered scientific institutions and operations breeding Appendix-I wildlife for commercial purposes; and... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD... and http://www.fws.gov/permits. (b) Scientific issues: (1) Animals and Plants Committees documents and...

  6. 50 CFR 17.41 - Special rules-birds.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...” (bred in captivity), or “D” (bred in captivity for commercial purposes)(see 50 CFR 23.24); or (ii... PLANTS (CONTINUED) ENDANGERED AND THREATENED WILDLIFE AND PLANTS Threatened Wildlife § 17.41 Special...: (i) Captive-bred specimens: The source code on the Convention on International Trade in Endangered...

  7. 50 CFR 23.7 - What office do I contact for CITES information?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... registered scientific institutions and operations breeding Appendix-I wildlife for commercial purposes; and... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD...://www.fws.gov/permits (b) Scientific issues: (1) Animals and Plants Committees documents and issues (2...

  8. 50 CFR 23.26 - When is a U.S. or foreign CITES document valid?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Registered commercial breeding operation for Appendix-I wildlife (i) The operation is included in the... document. (16) Registered commercial nursery for Appendix-I plants The operation is included in the... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD...

  9. 50 CFR 23.7 - What office do I contact for CITES information?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... registered scientific institutions and operations breeding Appendix-I wildlife for commercial purposes; and... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD...://www.fws.gov/permits (b) Scientific issues: (1) Animals and Plants Committees documents and issues (2...

  10. 50 CFR 23.23 - What information is required on U.S. and foreign CITES documents?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... artificially propagated plants, certificate for wildlife bred in captivity, certificate of origin, certificate..., EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN... CITES certificate for artificially propagated plants in paragraph (f) of this section, or a customs...

  11. 50 CFR 23.26 - When is a U.S. or foreign CITES document valid?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Registered commercial breeding operation for Appendix-I wildlife (i) The operation is included in the... document. (16) Registered commercial nursery for Appendix-I plants The operation is included in the... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD...

  12. 50 CFR 23.7 - What office do I contact for CITES information?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... registered scientific institutions and operations breeding Appendix-I wildlife for commercial purposes; and... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD...://www.fws.gov/permits (b) Scientific issues: (1) Animals and Plants Committees documents and issues (2...

  13. 50 CFR 23.23 - What information is required on U.S. and foreign CITES documents?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... artificially propagated plants, certificate for wildlife bred in captivity, certificate of origin, certificate..., EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN... CITES certificate for artificially propagated plants in paragraph (f) of this section, or a customs...

  14. 50 CFR 23.23 - What information is required on U.S. and foreign CITES documents?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... artificially propagated plants, certificate for wildlife bred in captivity, certificate of origin, certificate..., EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN... CITES certificate for artificially propagated plants in paragraph (f) of this section, or a customs...

  15. 50 CFR 17.72 - Permits-general.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... prior to the date the Convention applied to it, or (ii) the wildlife or plant was bred in captivity, or... PLANTS (CONTINUED) ENDANGERED AND THREATENED WILDLIFE AND PLANTS Threatened Plants § 17.72 Permits... otherwise prohibited with regard to threatened plants. The permit shall be governed by the provisions of...

  16. 50 CFR 23.36 - What are the requirements for an export permit?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Ginseng Appendix-I Plants Artificially Propagated for Commercial Purposes Biological Specimens Captive... noncommercial purposes. (See § 23.46 for the export of specimens that originated at a commercial breeding... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD...

  17. 50 CFR 23.27 - What CITES documents do I present at the port?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Appendix-I commercial breeding operation, export permit Required Required Required Registered Appendix-I... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD... presented. In the United States, for imports of CITES-listed plant specimens, CITES inspecting officials...

  18. 50 CFR 17.72 - Permits-general.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... prior to the date the Convention applied to it, or (ii) the wildlife or plant was bred in captivity, or... PLANTS (CONTINUED) ENDANGERED AND THREATENED WILDLIFE AND PLANTS Threatened Plants § 17.72 Permits... otherwise prohibited with regard to threatened plants. The permit shall be governed by the provisions of...

  19. 50 CFR 23.23 - What information is required on U.S. and foreign CITES documents?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... certificate for artificially propagated plants, certificate for wildlife bred in captivity, certificate of... for a registered commercial breeding operation or nursery for Appendix-I specimens (see § 23.46) The..., EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN...

  20. 50 CFR 17.72 - Permits-general.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... prior to the date the Convention applied to it, or (ii) the wildlife or plant was bred in captivity, or... PLANTS (CONTINUED) ENDANGERED AND THREATENED WILDLIFE AND PLANTS Threatened Plants § 17.72 Permits... otherwise prohibited with regard to threatened plants. The permit shall be governed by the provisions of...

  1. 50 CFR 23.23 - What information is required on U.S. and foreign CITES documents?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... artificially propagated plants, certificate for wildlife bred in captivity, certificate of origin, certificate..., EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN... CITES certificate for artificially propagated plants in paragraph (f) of this section, or a customs...

  2. 50 CFR 23.26 - When is a U.S. or foreign CITES document valid?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Registered commercial breeding operation for Appendix-I wildlife (i) The operation is included in the... document. (16) Registered commercial nursery for Appendix-I plants The operation is included in the... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD...

  3. 50 CFR 17.72 - Permits-general.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... prior to the date the Convention applied to it, or (ii) the wildlife or plant was bred in captivity, or... PLANTS (CONTINUED) ENDANGERED AND THREATENED WILDLIFE AND PLANTS Threatened Plants § 17.72 Permits... otherwise prohibited with regard to threatened plants. The permit shall be governed by the provisions of...

  4. 50 CFR 23.36 - What are the requirements for an export permit?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Ginseng Appendix-I Plants Artificially Propagated for Commercial Purposes Biological Specimens Captive... noncommercial purposes. (See § 23.46 for the export of specimens that originated at a commercial breeding... IMPORTATION OF WILDLIFE AND PLANTS (CONTINUED) CONVENTION ON INTERNATIONAL TRADE IN ENDANGERED SPECIES OF WILD...

  5. Writing for Change: Engaging Juveniles through Alternative Literacy Education

    ERIC Educational Resources Information Center

    Jacobi, Tobi

    2008-01-01

    Research on incarceration and educational access continues to reveal the stark reality for many adjudicated youth: without access to educational opportunities recidivism is probable. Yet conventional methods of teaching critical reading, writing, and thinking skills are not always successful for juveniles who have found little success (or hope) in…

  6. 46 CFR 69.67 - Marking of cargo spaces.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Marking of cargo spaces. 69.67 Section 69.67 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DOCUMENTATION AND MEASUREMENT OF VESSELS MEASUREMENT OF VESSELS Convention Measurement System § 69.67 Marking of cargo spaces. Cargo spaces used in...

  7. 46 CFR 69.67 - Marking of cargo spaces.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Marking of cargo spaces. 69.67 Section 69.67 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DOCUMENTATION AND MEASUREMENT OF VESSELS MEASUREMENT OF VESSELS Convention Measurement System § 69.67 Marking of cargo spaces. Cargo spaces used in...

  8. 46 CFR 69.67 - Marking of cargo spaces.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Marking of cargo spaces. 69.67 Section 69.67 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DOCUMENTATION AND MEASUREMENT OF VESSELS MEASUREMENT OF VESSELS Convention Measurement System § 69.67 Marking of cargo spaces. Cargo spaces used in...

  9. 46 CFR 69.67 - Marking of cargo spaces.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Marking of cargo spaces. 69.67 Section 69.67 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DOCUMENTATION AND MEASUREMENT OF VESSELS MEASUREMENT OF VESSELS Convention Measurement System § 69.67 Marking of cargo spaces. Cargo spaces used in...

  10. 46 CFR 69.67 - Marking of cargo spaces.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Marking of cargo spaces. 69.67 Section 69.67 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DOCUMENTATION AND MEASUREMENT OF VESSELS MEASUREMENT OF VESSELS Convention Measurement System § 69.67 Marking of cargo spaces. Cargo spaces used in...

  11. Contextual Learning and Tech Prep Curriculum Integration.

    ERIC Educational Resources Information Center

    Edling, Walter

    Because tech prep has the twin goals of preparing students for entry into postsecondary/continuing education or the work force after high school, tech prep programs require significant modification of conventional curricula and teaching methodologies. Both research and experience have demonstrated that the ability to transfer learning from one…

  12. 26 CFR 514.10 - Effective date.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 19 2011-04-01 2010-04-01 true Effective date. 514.10 Section 514.10 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS FRANCE Withholding of Tax § 514.10 Effective date. The provisions of §§ 514.1 through 517.9 shall be...

  13. Secondary Mathematics Course Trajectories: Understanding Accumulated Disadvantages in Mathematics in Grades 9-12

    ERIC Educational Resources Information Center

    Schiller, Kathryn S.; Hunt, Donald J.

    2011-01-01

    Schools are institutions in which students' course taking creates series of linked learning opportunities continually shaped by not only curricular structures but demographic and academic backgrounds. In contrast to a seven-step normative course sequence reflecting the conventional hierarchical structure of mathematics, analysis of more than…

  14. 15 CFR 716.2 - Purposes and types of inspections of declared facilities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... purpose of the Convention posed by the relevant chemicals, the characteristics of the plant site and the..., if applicable. (d) Unscheduled discrete organic chemical plant sites—(1) Purposes of inspections. The... Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS...

  15. 15 CFR 716.2 - Purposes and types of inspections of declared facilities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... purpose of the Convention posed by the relevant chemicals, the characteristics of the plant site and the..., if applicable. (d) Unscheduled discrete organic chemical plant sites—(1) Purposes of inspections. The... Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS...

  16. 15 CFR 716.2 - Purposes and types of inspections of declared facilities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... purpose of the Convention posed by the relevant chemicals, the characteristics of the plant site and the..., if applicable. (d) Unscheduled discrete organic chemical plant sites—(1) Purposes of inspections. The... Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS...

  17. 26 CFR 514.10 - Effective date.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 19 2010-04-01 2010-04-01 false Effective date. 514.10 Section 514.10 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS FRANCE Withholding of Tax § 514.10 Effective date. The provisions of §§ 514.1 through 517.9 shall be...

  18. Student Equity: Discouraging Cheating in Online Courses

    ERIC Educational Resources Information Center

    Michael, Timothy B.; Williams, Melissa A.

    2013-01-01

    As online programs at conventional universities continue to expand, administrators and faculty face new challenges. Academic dishonesty is nothing new, but an online testing environment requires different strategies and tactics from what we have had to consider in the past. Our university has recently adapted successful face-to-face programs in…

  19. An Evaluation Framework for Sustaining the Impact of Educational Development

    ERIC Educational Resources Information Center

    Hashimoto, Kazuaki; Pillay, Hitendra; Hudson, Peter

    2010-01-01

    Notwithstanding significant efforts by international aid agencies, aid ineffectiveness became apparent in 1990s as the impact of continued development intervention did not endure the expected outcomes. Conventional monitoring and evaluation by those agencies is critiqued for focusing on measuring project outcomes and giving little attention to…

  20. 26 CFR 521.107 - Income from operation of ships or aircraft.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 19 2010-04-01 2010-04-01 false Income from operation of ships or aircraft. 521.107 Section 521.107 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) REGULATIONS UNDER TAX CONVENTIONS DENMARK General Income Tax Taxation of Nonresident Aliens Who Are Residents...

Top