Sample records for conventional evaluation methods

  1. Evaluation of volatile organic emissions from hazardous waste incinerators.

    PubMed Central

    Sedman, R M; Esparza, J R

    1991-01-01

    Conventional methods of risk assessment typically employed to evaluate the impact of hazardous waste incinerators on public health must rely on somewhat speculative emissions estimates or on complicated and expensive sampling and analytical methods. The limited amount of toxicological information concerning many of the compounds detected in stack emissions also complicates the evaluation of the public health impacts of these facilities. An alternative approach aimed at evaluating the public health impacts associated with volatile organic stack emissions is presented that relies on a screening criterion to evaluate total stack hydrocarbon emissions. If the concentration of hydrocarbons in ambient air is below the screening criterion, volatile emissions from the incinerator are judged not to pose a significant threat to public health. Both the screening criterion and a conventional method of risk assessment were employed to evaluate the emissions from 20 incinerators. Use of the screening criterion always yielded a substantially greater estimate of risk than that derived by the conventional method. Since the use of the screening criterion always yielded estimates of risk that were greater than that determined by conventional methods and measuring total hydrocarbon emissions is a relatively simple analytical procedure, the use of the screening criterion would appear to facilitate the evaluation of operating hazardous waste incinerators. PMID:1954928

  2. Small-Scale System for Evaluation of Stretch-Flangeability with Excellent Reliability

    NASA Astrophysics Data System (ADS)

    Yoon, Jae Ik; Jung, Jaimyun; Lee, Hak Hyeon; Kim, Hyoung Seop

    2018-02-01

    We propose a system for evaluating the stretch-flangeability of small-scale specimens based on the hole-expansion ratio (HER). The system has no size effect and shows excellent reproducibility, reliability, and economic efficiency. To verify the reliability and reproducibility of the proposed hole-expansion testing (HET) method, the deformation behavior of the conventional standard stretch-flangeability evaluation method was compared with the proposed method using finite-element method simulations. The distribution of shearing defects in the hole-edge region of the specimen, which has a significant influence on the HER, was investigated using scanning electron microscopy. The stretch-flangeability of several kinds of advanced high-strength steel determined using the conventional standard method was compared with that using the proposed small-scale HET method. It was verified that the deformation behavior, morphology and distribution of shearing defects, and stretch-flangeability results for the specimens were the same for the conventional standard method and the proposed small-scale stretch-flangeability evaluation system.

  3. Small-Scale System for Evaluation of Stretch-Flangeability with Excellent Reliability

    NASA Astrophysics Data System (ADS)

    Yoon, Jae Ik; Jung, Jaimyun; Lee, Hak Hyeon; Kim, Hyoung Seop

    2018-06-01

    We propose a system for evaluating the stretch-flangeability of small-scale specimens based on the hole-expansion ratio (HER). The system has no size effect and shows excellent reproducibility, reliability, and economic efficiency. To verify the reliability and reproducibility of the proposed hole-expansion testing (HET) method, the deformation behavior of the conventional standard stretch-flangeability evaluation method was compared with the proposed method using finite-element method simulations. The distribution of shearing defects in the hole-edge region of the specimen, which has a significant influence on the HER, was investigated using scanning electron microscopy. The stretch-flangeability of several kinds of advanced high-strength steel determined using the conventional standard method was compared with that using the proposed small-scale HET method. It was verified that the deformation behavior, morphology and distribution of shearing defects, and stretch-flangeability results for the specimens were the same for the conventional standard method and the proposed small-scale stretch-flangeability evaluation system.

  4. Ictal SPECT using an attachable automated injector: clinical usefulness in the prediction of ictal onset zone.

    PubMed

    Lee, Jung-Ju; Lee, Sang Kun; Choi, Jang Wuk; Kim, Dong-Wook; Park, Kyung Il; Kim, Bom Sahn; Kang, Hyejin; Lee, Dong Soo; Lee, Seo-Young; Kim, Sung Hun; Chung, Chun Kee; Nam, Hyeon Woo; Kim, Kwang Ki

    2009-12-01

    Ictal single-photon emission computed tomography (SPECT) is a valuable method for localizing the ictal onset zone in the presurgical evaluation of patients with intractable epilepsy. Conventional methods used to localize the ictal onset zone have problems with time lag from seizure onset to injection. To evaluate the clinical usefulness of a method that we developed, which involves an attachable automated injector (AAI), in reducing time lag and improving the ability to localize the zone of seizure onset. Patients admitted to the epilepsy monitoring unit (EMU) between January 1, 2003, and June 30, 2008, were included. The definition of ictal onset zone was made by comprehensive review of medical records, magnetic resonance imaging (MRI), data from video electroencephalography (EEG) monitoring, and invasive EEG monitoring if available. We comprehensively evaluated the time lag to injection and the image patterns of ictal SPECT using traditional visual analysis, statistical parametric mapping-assisted, and subtraction ictal SPECT coregistered to an MRI-assisted means of analysis. Image patterns were classified as localizing, lateralizing, and nonlateralizing. The whole number of patients was 99: 48 in the conventional group and 51 in the AAI group. The mean (SD) delay time to injection from seizure onset was 12.4+/-12.0 s in the group injected by our AAI method and 40.4+/-26.3 s in the group injected by the conventional method (P=0.000). The mean delay time to injection from seizure detection was 3.2+/-2.5 s in the group injected by the AAI method and 21.4+/-9.7 s in the group injected by the conventional method (P=0.000). The AAI method was superior to the conventional method in localizing the area of seizure onset (36 out of 51 with AAI method vs. 21 out of 48 with conventional method, P=0.009), especially in non-temporal lobe epilepsy (non-TLE) patients (17 out of 27 with AAI method vs. 3 out of 13 with conventional method, P=0.041), and in lateralizing the seizure onset hemisphere (47 out of 51 with AAI method vs. 33 out of 48 with conventional method, P=0.004). The AAI method was superior to the conventional method in reducing the time lag of tracer injection and in localizing and lateralizing the ictal onset zone, especially in patients with non-TLE.

  5. [Studies on the dynamic durability of dental restorative materials. Part 4. Materials evaluation of initial and fatigue specimen for composite resins by acoustic emission method].

    PubMed

    Kondo, S; Okawa, S; Hanawa, T; Sugawara, T; Ota, M

    1981-10-01

    Present study is directed towards development for a method of materials evaluation of the static and dynamic properties for dental restorative materials and nondestructive inspection of the dental restorations in oral cavity by acoustic emission (AE) method. AE characteristics and deformation-fracture behavior of hour commercial composite resins under three points bending test are examined in order to evaluate initial and fatigue specimen for conventional and microfilled composite resins. Experimental results obtained are as follows: (1) Deformation-fracture behavior of conventional and microfilled composite resins exhibits different mode, corresponding to relatively brittle and ductile fracture behavior, respectively. Therefore, the primary sources of AE for conventional and microfilled composite resins under bending test are related mainly to the nucleation and propagation of cracks and plastic deformation, respectively. (2) In conventional composite resins under bending test, the burst type AE signal of higher amplitude and shorter decay time and more many AE total counts tend to be observed. In microfilled composite resins under bending test, the burst type AE signal of lower amplitude and longer decay time and more a few total counts tend to be observed. (3) Composite resins, particularly conventional composite resins under unload and repeated bending load are indicative of different AE characteristics. Accordingly, application of AE method for composite resins offers a method to evaluate the static and dynamic strength of composite resins. (4) In conventional composite resins under bending test, as characteristic AE are observed in a few stress regions before fracture, it may be possible to monitor nondestructively the restorations in oral cavity by using AE method.

  6. Approximating genomic reliabilities for national genomic evaluation

    USDA-ARS?s Scientific Manuscript database

    With the introduction of standard methods for approximating effective daughter/data contribution by Interbull in 2001, conventional EDC or reliabilities contributed by daughter phenotypes are directly comparable across countries and used in routine conventional evaluations. In order to make publishe...

  7. Developing new automated alternation flicker using optic disc photography for the detection of glaucoma progression

    PubMed Central

    Ahn, J; Yun, I S; Yoo, H G; Choi, J-J; Lee, M

    2017-01-01

    Purpose To evaluate a progression-detecting algorithm for a new automated matched alternation flicker (AMAF) in glaucoma patients. Methods Open-angle glaucoma patients with a baseline mean deviation of visual field (VF) test>−6 dB were included in this longitudinal and retrospective study. Functional progression was detected by two VF progression criteria and structural progression by both AMAF and conventional comparison methods using optic disc and retinal nerve fiber layer (RNFL) photography. Progression-detecting performances of AMAF and the conventional method were evaluated by an agreement between functional and structural progression criteria. RNFL thickness changes measured by optical coherence tomography (OCT) were compared between progressing and stable eyes determined by each method. Results Among 103 eyes, 47 (45.6%), 21 (20.4%), and 32 (31.1%) eyes were evaluated as glaucoma progression using AMAF, the conventional method, and guided progression analysis (GPA) of the VF test, respectively. The AMAF showed better agreement than the conventional method, using GPA of the VF test (κ=0.337; P<0.001 and κ=0.124; P=0.191, respectively). The rates of RNFL thickness decay using OCT were significantly different between the progressing and stable eyes when progression was determined by AMAF (−3.49±2.86 μm per year vs −1.83±3.22 μm per year; P=0.007) but not by the conventional method (−3.24±2.42 μm per year vs −2.42±3.33 μm per year; P=0.290). Conclusions The AMAF was better than the conventional comparison method in discriminating structural changes during glaucoma progression, and showed a moderate agreement with functional progression criteria. PMID:27662466

  8. Novel Method for Superposing 3D Digital Models for Monitoring Orthodontic Tooth Movement.

    PubMed

    Schmidt, Falko; Kilic, Fatih; Piro, Neltje Emma; Geiger, Martin Eberhard; Lapatki, Bernd Georg

    2018-04-18

    Quantitative three-dimensional analysis of orthodontic tooth movement (OTM) is possible by superposition of digital jaw models made at different times during treatment. Conventional methods rely on surface alignment at palatal soft-tissue areas, which is applicable to the maxilla only. We introduce two novel numerical methods applicable to both maxilla and mandible. The OTM from the initial phase of multi-bracket appliance treatment of ten pairs of maxillary models were evaluated and compared with four conventional methods. The median range of deviation of OTM for three users was 13-72% smaller for the novel methods than for the conventional methods, indicating greater inter-observer agreement. Total tooth translation and rotation were significantly different (ANOVA, p < 0.01) for OTM determined by use of the two numerical and four conventional methods. Directional decomposition of OTM from the novel methods showed clinically acceptable agreement with reference results except for vertical translations (deviations of medians greater than 0.6 mm). The difference in vertical translational OTM can be explained by maxillary vertical growth during the observation period, which is additionally recorded by conventional methods. The novel approaches are, thus, particularly suitable for evaluation of pure treatment effects, because growth-related changes are ignored.

  9. [Study of CT Automatic Exposure Control System (CT-AEC) Optimization in CT Angiography of Lower Extremity Artery by Considering Contrast-to-Noise Ratio].

    PubMed

    Inada, Satoshi; Masuda, Takanori; Maruyama, Naoya; Yamashita, Yukari; Sato, Tomoyasu; Imada, Naoyuki

    2016-01-01

    To evaluate the image quality and effect of radiation dose reduction by setting for computed tomography automatic exposure control system (CT-AEC) in computed tomographic angiography (CTA) of lower extremity artery. Two methods of setting were compared for CT-AEC [conventional and contrast-to-noise ratio (CNR) methods]. Conventional method was set noise index (NI): 14and tube current threshold: 10-750 mA. CNR method was set NI: 18, minimum tube current: (X+Y)/2 mA (X, Y: maximum X (Y)-axis tube current value of leg in NI: 14), and maximum tube current: 750 mA. The image quality was evaluated by CNR, and radiation dose reduction was evaluated by dose-length-product (DLP). In conventional method, mean CNRs for pelvis, femur, and leg were 19.9±4.8, 20.4±5.4, and 16.2±4.3, respectively. There was a significant difference between the CNRs of pelvis and leg (P<0.001), and between femur and leg (P<0.001). In CNR method, mean CNRs for pelvis, femur, and leg were 15.2±3.3, 15.3±3.2, and 15.3±3.1, respectively; no significant difference between pelvis, femur, and leg (P=0.973) in CNR method was observed. Mean DLPs were 1457±434 mGy⋅cm in conventional method, and 1049±434 mGy·cm in CNR method. There was a significant difference in the DLPs of conventional method and CNR method (P<0.001). CNR method gave equal CNRs for pelvis, femur, and leg, and was beneficial for radiation dose reduction in CTA of lower extremity artery.

  10. Comparison of performance due to guided hyperlearning, unguided hyperlearning, and conventional learning in mathematics: an empirical study

    NASA Astrophysics Data System (ADS)

    Fathurrohman, Maman; Porter, Anne; Worthy, Annette L.

    2014-07-01

    In this paper, the use of guided hyperlearning, unguided hyperlearning, and conventional learning methods in mathematics are compared. The design of the research involved a quasi-experiment with a modified single-factor multiple treatment design comparing the three learning methods, guided hyperlearning, unguided hyperlearning, and conventional learning. The participants were from three first-year university classes, numbering 115 students in total. Each group received guided, unguided, or conventional learning methods in one of the three different topics, namely number systems, functions, and graphing. The students' academic performance differed according to the type of learning. Evaluation of the three methods revealed that only guided hyperlearning and conventional learning were appropriate methods for the psychomotor aspects of drawing in the graphing topic. There was no significant difference between the methods when learning the cognitive aspects involved in the number systems topic and the functions topic.

  11. Digital evaluation of absolute marginal discrepancy: A comparison of ceramic crowns fabricated with conventional and digital techniques.

    PubMed

    Liang, Shanshan; Yuan, Fusong; Luo, Xu; Yu, Zhuoren; Tang, Zhihui

    2018-04-05

    Marginal discrepancy is key to evaluating the accuracy of fixed dental prostheses. An improved method of evaluating marginal discrepancy is needed. The purpose of this in vitro study was to evaluate the absolute marginal discrepancy of ceramic crowns fabricated using conventional and digital methods with a digital method for the quantitative evaluation of absolute marginal discrepancy. The novel method was based on 3-dimensional scanning, iterative closest point registration techniques, and reverse engineering theory. Six standard tooth preparations for the right maxillary central incisor, right maxillary second premolar, right maxillary second molar, left mandibular lateral incisor, left mandibular first premolar, and left mandibular first molar were selected. Ten conventional ceramic crowns and 10 CEREC crowns were fabricated for each tooth preparation. A dental cast scanner was used to obtain 3-dimensional data of the preparations and ceramic crowns, and the data were compared with the "virtual seating" iterative closest point technique. Reverse engineering software used edge sharpening and other functional modules to extract the margins of the preparations and crowns. Finally, quantitative evaluation of the absolute marginal discrepancy of the ceramic crowns was obtained from the 2-dimensional cross-sectional straight-line distance between points on the margin of the ceramic crowns and the standard preparations based on the circumferential function module along the long axis. The absolute marginal discrepancy of the ceramic crowns fabricated using conventional methods was 115 ±15.2 μm, and 110 ±14.3 μm for those fabricated using the digital technique was. ANOVA showed no statistical difference between the 2 methods or among ceramic crowns for different teeth (P>.05). The digital quantitative evaluation method for the absolute marginal discrepancy of ceramic crowns was established. The evaluations determined that the absolute marginal discrepancies were within a clinically acceptable range. This method is acceptable for the digital evaluation of the accuracy of complete crowns. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Accuracy assessment methods of tissue marker clip placement after 11-gauge vacuum-assisted stereotactic breast biopsy: comparison of measurements using direct and conventional methods.

    PubMed

    Yatake, Hidetoshi; Sawai, Yuka; Nishi, Toshio; Nakano, Yoshiaki; Nishimae, Ayaka; Katsuda, Toshizo; Yabunaka, Koichi; Takeda, Yoshihiro; Inaji, Hideo

    2017-07-01

    The objective of the study was to compare direct measurement with a conventional method for evaluation of clip placement in stereotactic vacuum-assisted breast biopsy (ST-VAB) and to evaluate the accuracy of clip placement using the direct method. Accuracy of clip placement was assessed by measuring the distance from a residual calcification of a targeted calcification clustered to a clip on a mammogram after ST-VAB. Distances in the craniocaudal (CC) and mediolateral oblique (MLO) views were measured in 28 subjects with mammograms recorded twice or more after ST-VAB. The difference in the distance between the first and second measurements was defined as the reproducibility and was compared with that from a conventional method using a mask system with overlap of transparent film on the mammogram. The 3D clip-to-calcification distance was measured using the direct method in 71 subjects. The reproducibility of the direct method was higher than that of the conventional method in CC and MLO views (P = 0.002, P < 0.001). The median 3D clip-to-calcification distance was 2.8 mm, with an interquartile range of 2.0-4.8 mm and a range of 1.1-36.3 mm. The direct method used in this study was more accurate than the conventional method, and gave a median 3D distance of 2.8 mm between the calcification and clip.

  13. Performance of two alternative methods for Listeria detection throughout Serro Minas cheese ripening.

    PubMed

    Mata, Gardênia Márcia Silva Campos; Martins, Evandro; Machado, Solimar Gonçalves; Pinto, Maximiliano Soares; de Carvalho, Antônio Fernandes; Vanetti, Maria Cristina Dantas

    2016-01-01

    The ability of pathogens to survive cheese ripening is a food-security concern. Therefore, this study aimed to evaluate the performance of two alternative methods of analysis of Listeria during the ripening of artisanal Minas cheese. These methods were tested and compared with the conventional method: Lateral Flow System™, in cheeses produced on laboratory scale using raw milk collected from different farms and inoculated with Listeria innocua; and VIDAS(®)-LMO, in cheese samples collected from different manufacturers in Serro, Minas Gerais, Brazil. These samples were also characterized in terms of lactic acid bacteria, coliforms and physical-chemical analysis. In the inoculated samples, L. innocua was detected by Lateral Flow System™ method with 33% false-negative and 68% accuracy results. L. innocua was only detected in the inoculated samples by the conventional method at 60-days of cheese ripening. L. monocytogenes was not detected by the conventional and the VIDAS(®)-LMO methods in cheese samples collected from different manufacturers, which impairs evaluating the performance of this alternative method. We concluded that the conventional method provided a better recovery of L. innocua throughout cheese ripening, being able to detect L. innocua at 60-day, aging period which is required by the current legislation. Copyright © 2016 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.

  14. Using a second‐order differential model to fit data without baselines in protein isothermal chemical denaturation

    PubMed Central

    Tang, Chuanning; Lew, Scott

    2016-01-01

    Abstract In vitro protein stability studies are commonly conducted via thermal or chemical denaturation/renaturation of protein. Conventional data analyses on the protein unfolding/(re)folding require well‐defined pre‐ and post‐transition baselines to evaluate Gibbs free‐energy change associated with the protein unfolding/(re)folding. This evaluation becomes problematic when there is insufficient data for determining the pre‐ or post‐transition baselines. In this study, fitting on such partial data obtained in protein chemical denaturation is established by introducing second‐order differential (SOD) analysis to overcome the limitations that the conventional fitting method has. By reducing numbers of the baseline‐related fitting parameters, the SOD analysis can successfully fit incomplete chemical denaturation data sets with high agreement to the conventional evaluation on the equivalent completed data, where the conventional fitting fails in analyzing them. This SOD fitting for the abbreviated isothermal chemical denaturation further fulfills data analysis methods on the insufficient data sets conducted in the two prevalent protein stability studies. PMID:26757366

  15. Proceedings of Workshop on Methodology for Evaluating the Effectiveness of Transit Crime Reduction Measures in Automated Guideway Transit Systems

    DOT National Transportation Integrated Search

    1977-07-01

    The workshop focused on current methods of assessing the effectiveness of crime and vandalism reduction methods that are used in conventional urban mass transit systems, and on how they might be applied to new AGT systems. Conventional as well as nov...

  16. Complementary and alternative medicine: attitudes, knowledge and use among surgeons and anaesthesiologists in Hungary.

    PubMed

    Soós, Sándor Árpád; Jeszenői, Norbert; Darvas, Katalin; Harsányi, László

    2016-11-08

    Despite their worldwide popularity the question of using non-conventional treatments is a source of controversy among medical professionals. Although these methods may have potential benefits it presents a problem when patients use non-conventional treatments in the perioperative period without informing their attending physician about it and this may cause adverse events and complications. To prevent this, physicians need to have a profound knowledge about non-conventional treatments. An anonymous questionnaire was distributed among surgeons and anaesthesiologists working in Hungarian university clinics and in selected city or county hospitals. Questionnaires were distributed by post, online or in person. Altogether 258 questionnaires were received from 22 clinical and hospital departments. Anaesthesiologists and surgeons use reflexology, Traditional Chinese Medicine, herbal medicine and manual therapy most frequently in their clinical practice. Traditional Chinese Medicine was considered to be the most scientifically sound method, while homeopathy was perceived as the least well-grounded method. Neural therapy was the least well-known method among our subjects. Among the subjects of our survey only 3.1 % of perioperative care physicians had some qualifications in non-conventional medicine, 12.4 % considered themselves to be well-informed in this topic and 48.4 % would like to study some complementary method. Women were significantly more interested in alternative treatments than men, p = 0.001427; OR: 2.2765. Anaesthesiologists would be significantly more willing to learn non-conventional methods than surgeons. 86.4 % of the participants thought that non-conventional treatments should be evaluated from the point of view of evidence. Both surgeons and anaesthesiologists accept the application of integrative medicine and they also approve of the idea of teaching these methods at universities. According to perioperative care physicians, non-conventional methods should be evaluated based on evidence. They also expressed a willingness to learn about those treatments that meet the criteria of evidence and apply these in their clinical practice.

  17. A risk assessment methodology using intuitionistic fuzzy set in FMEA

    NASA Astrophysics Data System (ADS)

    Chang, Kuei-Hu; Cheng, Ching-Hsue

    2010-12-01

    Most current risk assessment methods use the risk priority number (RPN) value to evaluate the risk of failure. However, conventional RPN methodology has been criticised as having five main shortcomings as follows: (1) the assumption that the RPN elements are equally weighted leads to over simplification; (2) the RPN scale itself has some non-intuitive statistical properties; (3) the RPN elements have many duplicate numbers; (4) the RPN is derived from only three factors mainly in terms of safety; and (5) the conventional RPN method has not considered indirect relations between components. To address the above issues, an efficient and comprehensive algorithm to evaluate the risk of failure is needed. This article proposes an innovative approach, which integrates the intuitionistic fuzzy set (IFS) and the decision-making trial and evaluation laboratory (DEMATEL) approach on risk assessment. The proposed approach resolves some of the shortcomings of the conventional RPN method. A case study, which assesses the risk of 0.15 µm DRAM etching process, is used to demonstrate the effectiveness of the proposed approach. Finally, the result of the proposed method is compared with the listing approaches of risk assessment methods.

  18. Test Methodology to Evaluate the Safety of Materials Using Spark Incendivity

    NASA Technical Reports Server (NTRS)

    Buhler, Charles; Calle, Carlos; Clements, Sid; Ritz, Mindy; Starnes, Jeff

    2007-01-01

    For many years scientists and engineers have been searching for the proper test method to evaluate an electrostatic risk for materials used in hazardous environments. A new test standard created by the International Electrotechnical Commission is a promising addition to conventional test methods used throughout industry. The purpose of this paper is to incorporate this test into a proposed new methodology for the evaluation of materials exposed to flammable environments. However, initial testing using this new standard has uncovered some unconventional behavior in materials that conventional test methods were thought to have reconciled. For example some materials tested at higher humidities were more susceptible to incendive discharges than at lower humidity even though the surface resistivity was lower.

  19. Slump sitting X-ray of the lumbar spine is superior to the conventional flexion view in assessing lumbar spine instability.

    PubMed

    Hey, Hwee Weng Dennis; Lau, Eugene Tze-Chun; Lim, Joel-Louis; Choong, Denise Ai-Wen; Tan, Chuen-Seng; Liu, Gabriel Ka-Po; Wong, Hee-Kit

    2017-03-01

    Flexion radiographs have been used to identify cases of spinal instability. However, current methods are not standardized and are not sufficiently sensitive or specific to identify instability. This study aimed to introduce a new slump sitting method for performing lumbar spine flexion radiographs and comparison of the angular range of motions (ROMs) and displacements between the conventional method and this new method. This study used is a prospective study on radiological evaluation of the lumbar spine flexion ROMs and displacements using dynamic radiographs. Sixty patients were recruited from a single spine tertiary center. Angular and displacement measurements of lumbar spine flexion were carried out. Participants were randomly allocated into two groups: those who did the new method first, followed by the conventional method versus those who did the conventional method first, followed by the new method. A comparison of the angular and displacement measurements of lumbar spine flexion between the conventional method and the new method was performed and tested for superiority and non-inferiority. The measurements of global lumbar angular ROM were, on average, 17.3° larger (p<.0001) using the new slump sitting method compared with the conventional method. They were most significant at the levels of L3-L4, L4-L5, and L5-S1 (p<.0001, p<.0001 and p=.001, respectively). There was no significant difference between both methods when measuring lumbar displacements (p=.814). The new method of slump sitting dynamic radiograph was shown to be superior to the conventional method in measuring the angular ROM and non-inferior to the conventional method in the measurement of displacement. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Real-time performance assessment and adaptive control for a water chiller unit in an HVAC system

    NASA Astrophysics Data System (ADS)

    Bai, Jianbo; Li, Yang; Chen, Jianhao

    2018-02-01

    The paper proposes an adaptive control method for a water chiller unit in a HVAC system. Based on the minimum variance evaluation, the adaptive control method was used to realize better control of the water chiller unit. To verify the performance of the adaptive control method, the proposed method was compared with an a conventional PID controller, the simulation results showed that adaptive control method had superior control performance to that of the conventional PID controller.

  1. A pilot study comparing the effectiveness of conventional training and virtual reality simulation in the skills acquisition of junior dental students.

    PubMed

    Quinn, Frank; Keogh, Paul; McDonald, Ailbhe; Hussey, David

    2003-02-01

    The use of virtual reality (VR) in the training of operative dentistry is a recent innovation and little research has been published on its efficacy compared to conventional training methods. To evaluate possible benefits, junior undergraduate dental students were randomly assigned to one of three groups: group 1 as taught by conventional means only; group 2 as trained by conventional means combined with VR repetition and reinforcement (with access to a human instructor for operative advice); and group 3 as trained by conventional means combined with VR repetition and reinforcement, but without instructor evaluation/advice, which was only supplied via the VR-associated software. At the end of the research period, all groups executed two class 1 preparations that were evaluated blindly by 'expert' trainers, under traditional criteria (outline, retention, smoothness, depth, wall angulation and cavity margin index). Analyses of resulting scores indicated a lack of significant differences between the three groups except for scores for the category of 'outline form', for group 2, which produced significantly lower (i.e. better) scores than the conventionally trained group. A statistical comparison between scores from two 'expert' examiners indicated lack of agreement, despite identical written and visual criteria being used for evaluation by both. Both examiners, however, generally showed similar trends in evaluation. An anonymous questionnaire suggested that students recognized the benefits of VR training (e.g. ready access to assessment, error identification and how they can be corrected), but the majority felt that it would not replace conventional training methods (95%), although participants recognized the potential for development of VR systems in dentistry. The most common reasons cited for the preference of conventional training were excessive critical feedback (55%), lack of personal contact (50%) and technical hardware difficulties (20%) associated with VR-based training.

  2. Evaluation of radiation loading on finite cylindrical shells using the fast Fourier transform: A comparison with direct numerical integration.

    PubMed

    Liu, S X; Zou, M S

    2018-03-01

    The radiation loading on a vibratory finite cylindrical shell is conventionally evaluated through the direct numerical integration (DNI) method. An alternative strategy via the fast Fourier transform algorithm is put forward in this work based on the general expression of radiation impedance. To check the feasibility and efficiency of the proposed method, a comparison with DNI is presented through numerical cases. The results obtained using the present method agree well with those calculated by DNI. More importantly, the proposed calculating strategy can significantly save the time cost compared with the conventional approach of straightforward numerical integration.

  3. WOODSTOVE EMISSION SAMPLING METHODS COMPARABILITY ANALYSIS AND IN-SITU EVALUATION OF NEW TECHNOLOGY WOODSTOVES

    EPA Science Inventory

    This report compares simultaneous results from three woodstove sampling methods and evaluates particulate emission rates of conventional and Oregon-certified catalytic and noncatalytic woodstoves in six Portland, OR, houses. EPA Methods 5G and 5H and the field emission sampler (A...

  4. Comparing conventional Descriptive Analysis and Napping®-UFP against physiochemical measurements: a case study using apples.

    PubMed

    Pickup, William; Bremer, Phil; Peng, Mei

    2018-03-01

    The extensive time and cost associated with conventional sensory profiling methods has spurred sensory researchers to develop rapid method alternatives, such as Napping® with Ultra-Flash Profiling (UFP). Napping®-UFP generates sensory maps by requiring untrained panellists to separate samples based on perceived sensory similarities. Evaluations of this method have been restrained to manufactured/formulated food models, and predominantly structured on comparisons against the conventional descriptive method. The present study aims to extend the validation of Napping®-UFP (N = 72) to natural biological products; and to evaluate this method against Descriptive Analysis (DA; N = 8) with physiochemical measurements as an additional evaluative criterion. The results revealed that sample configurations generated by DA and Napping®-UFP were not significantly correlated (RV = 0.425, P = 0.077); however, they were both correlated with the product map generated based on the instrumental measures (P < 0.05). The finding also noted that sample characterisations from DA and Napping®-UFP were driven by different sensory attributes, indicating potential structural differences between these two methods in configuring samples. Overall, these findings lent support for the extended use of Napping®-UFP for evaluations of natural biological products. Although DA was shown to be a better method for establishing sensory-instrumental relationships, Napping®-UFP exhibited strengths in generating informative sample configurations based on holistic perception of products. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  5. Quantitative T1 and T2* carotid atherosclerotic plaque imaging using a three-dimensional multi-echo phase-sensitive inversion recovery sequence: a feasibility study.

    PubMed

    Fujiwara, Yasuhiro; Maruyama, Hirotoshi; Toyomaru, Kanako; Nishizaka, Yuri; Fukamatsu, Masahiro

    2018-06-01

    Magnetic resonance imaging (MRI) is widely used to detect carotid atherosclerotic plaques. Although it is important to evaluate vulnerable carotid plaques containing lipids and intra-plaque hemorrhages (IPHs) using T 1 -weighted images, the image contrast changes depending on the imaging settings. Moreover, to distinguish between a thrombus and a hemorrhage, it is useful to evaluate the iron content of the plaque using both T 1 -weighted and T 2 *-weighted images. Therefore, a quantitative evaluation of carotid atherosclerotic plaques using T 1 and T 2 * values may be necessary for the accurate evaluation of plaque components. The purpose of this study was to determine whether the multi-echo phase-sensitive inversion recovery (mPSIR) sequence can improve T 1 contrast while simultaneously providing accurate T 1 and T 2 * values of an IPH. T 1 and T 2 * values measured using mPSIR were compared to values from conventional methods in phantom and in vivo studies. In the phantom study, the T 1 and T 2 * values estimated using mPSIR were linearly correlated with those of conventional methods. In the in vivo study, mPSIR demonstrated higher T 1 contrast between the IPH phantom and sternocleidomastoid muscle than the conventional method. Moreover, the T 1 and T 2 * values of the blood vessel wall and sternocleidomastoid muscle estimated using mPSIR were correlated with values measured by conventional methods and with values reported previously. The mPSIR sequence improved T 1 contrast while simultaneously providing accurate T 1 and T 2 * values of the neck region. Although further study is required to evaluate the clinical utility, mPSIR may improve carotid atherosclerotic plaque detection and provide detailed information about plaque components.

  6. Superiority of automatic remote monitoring compared with in-person evaluation for scheduled ICD follow-up in the TRUST trial - testing execution of the recommendations

    PubMed Central

    Varma, Niraj; Michalski, Justin; Stambler, Bruce; Pavri, Behzad B.

    2014-01-01

    Aims To test recommended implantable cardioverter defibrillator (ICD) follow-up methods by ‘in-person evaluations’ (IPE) vs. ‘remote Home Monitoring’ (HM). Methods and results ICD patients were randomized 2:1 to automatic HM or to Conventional monitoring, with follow-up checks scheduled at 3, 6, 9, 12, and 15 months post-implant. Conventional patients were evaluated with IPE only. Home Monitoring patients were assessed remotely only for 1 year between 3 and 15 month evaluations. Adherence to follow-up was measured. HM and Conventional patients were similar (age 63 years, 72% male, left ventricular ejection fraction 29%, primary prevention 73%, DDD 57%). Conventional management suffered greater patient attrition during the trial (20.1 vs. 14.2% in HM, P = 0.007). Three month follow-up occurred in 84% in both groups. There was 100% adherence (5 of 5 checks) in 47.3% Conventional vs. 59.7% HM (P < 0.001). Between 3 and 15 months, HM exhibited superior (2.2×) adherence to scheduled follow-up [incidence of failed follow up was 146 of 2421 (6.0%) in HM vs. 145 of 1098 (13.2%) in Conventional, P < 0.001] and punctuality. In HM (daily transmission success rate median 91%), transmission loss caused only 22 of 2275 (0.97%) failed HM evaluations between 3 and 15 months; others resulted from clinic oversight. Overall IPE failure rate in Conventional [193 of 1841 (10.5%) exceeded that in HM [97 of 1484 (6.5%), P < 0.001] by 62%, i.e. HM patients remained more loyal to IPE when this was mandated. Conclusion Automatic remote monitoring better preserves patient retention and adherence to scheduled follow-up compared with IPE. Clinical trial registration NCT00336284. PMID:24595864

  7. [Evaluation of Wits appraisal with superimposition method].

    PubMed

    Xu, T; Ahn, J; Baumrind, S

    1999-07-01

    To compare the conventional Wits appraisal with superimposed Wits appraisal in evaluation of sagittal jaw relationship change between pre and post orthodontic treatment. The sample consists of 48-case pre and post treatment lateral head films. Computerized digitizing is used to get the cephalometric landmarks and measure conventional Wits value, superimposed Wits value and ANB angle. The correlation analysis among these three measures was done by SAS statistical package. The change of ANB angle has higher correlation with the change of superimposed Wits than that of the conventional Wits. The r-value is as high as 0.849 (P < 0.001). The superimposed Wits appraisal reflects the change of sagittal jaw relationship more objectively than the conventional one.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hohimer, J.P.

    The use of laser-based analytical methods in nuclear-fuel processing plants is considered. The species and locations for accountability, process control, and effluent control measurements in the Coprocessing, Thorex, and reference Purex fuel processing operations are identified and the conventional analytical methods used for these measurements are summarized. The laser analytical methods based upon Raman, absorption, fluorescence, and nonlinear spectroscopy are reviewed and evaluated for their use in fuel processing plants. After a comparison of the capabilities of the laser-based and conventional analytical methods, the promising areas of application of the laser-based methods in fuel processing plants are identified.

  9. SPACE PROPULSION SYSTEM PHASED-MISSION PROBABILITY ANALYSIS USING CONVENTIONAL PRA METHODS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Curtis Smith; James Knudsen

    As part of a series of papers on the topic of advance probabilistic methods, a benchmark phased-mission problem has been suggested. This problem consists of modeling a space mission using an ion propulsion system, where the mission consists of seven mission phases. The mission requires that the propulsion operate for several phases, where the configuration changes as a function of phase. The ion propulsion system itself consists of five thruster assemblies and a single propellant supply, where each thruster assembly has one propulsion power unit and two ion engines. In this paper, we evaluate the probability of mission failure usingmore » the conventional methodology of event tree/fault tree analysis. The event tree and fault trees are developed and analyzed using Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE). While the benchmark problem is nominally a "dynamic" problem, in our analysis the mission phases are modeled in a single event tree to show the progression from one phase to the next. The propulsion system is modeled in fault trees to account for the operation; or in this case, the failure of the system. Specifically, the propulsion system is decomposed into each of the five thruster assemblies and fed into the appropriate N-out-of-M gate to evaluate mission failure. A separate fault tree for the propulsion system is developed to account for the different success criteria of each mission phase. Common-cause failure modeling is treated using traditional (i.e., parametrically) methods. As part of this paper, we discuss the overall results in addition to the positive and negative aspects of modeling dynamic situations with non-dynamic modeling techniques. One insight from the use of this conventional method for analyzing the benchmark problem is that it requires significant manual manipulation to the fault trees and how they are linked into the event tree. The conventional method also requires editing the resultant cut sets to obtain the correct results. While conventional methods may be used to evaluate a dynamic system like that in the benchmark, the level of effort required may preclude its use on real-world problems.« less

  10. Evaluation of the White Test for the Intraoperative Detection of Bile Leakage

    PubMed Central

    Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-ad

    2012-01-01

    We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was compared between the conventional method and the White test. A bile leak was demonstrated in 8 patients (26.7%) by the conventional method and in 19 patients (63.3%) by the White test. In addition, the White test detected a significantly higher number of bile leakage sites compared with the conventional method (Wilcoxon signed-rank test; P < 0.001). The White test is better than the conventional test for the intraoperative detection of bile leakage. Based on our study, we recommend that surgeons investigating bile leakage sites during liver resections should use the White test instead of the conventional bile leakage test. PMID:22547901

  11. Evaluation of the white test for the intraoperative detection of bile leakage.

    PubMed

    Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-Ad

    2012-01-01

    We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was compared between the conventional method and the White test. A bile leak was demonstrated in 8 patients (26.7%) by the conventional method and in 19 patients (63.3%) by the White test. In addition, the White test detected a significantly higher number of bile leakage sites compared with the conventional method (Wilcoxon signed-rank test; P < 0.001). The White test is better than the conventional test for the intraoperative detection of bile leakage. Based on our study, we recommend that surgeons investigating bile leakage sites during liver resections should use the White test instead of the conventional bile leakage test.

  12. Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review.

    PubMed

    Ahlholm, Pekka; Sipilä, Kirsi; Vallittu, Pekka; Jakonen, Minna; Kotiranta, Ulla

    2018-01-01

    To conduct a systematic review to evaluate the evidence of possible benefits and accuracy of digital impression techniques vs. conventional impression techniques. Reports of digital impression techniques versus conventional impression techniques were systematically searched for in the following databases: Cochrane Central Register of Controlled Trials, PubMed, and Web of Science. A combination of controlled vocabulary, free-text words, and well-defined inclusion and exclusion criteria guided the search. Digital impression accuracy is at the same level as conventional impression methods in fabrication of crowns and short fixed dental prostheses (FDPs). For fabrication of implant-supported crowns and FDPs, digital impression accuracy is clinically acceptable. In full-arch impressions, conventional impression methods resulted in better accuracy compared to digital impressions. Digital impression techniques are a clinically acceptable alternative to conventional impression methods in fabrication of crowns and short FDPs. For fabrication of implant-supported crowns and FDPs, digital impression systems also result in clinically acceptable fit. Digital impression techniques are faster and can shorten the operation time. Based on this study, the conventional impression technique is still recommended for full-arch impressions. © 2016 by the American College of Prosthodontists.

  13. Why conventional detection methods fail in identifying the existence of contamination events.

    PubMed

    Liu, Shuming; Li, Ruonan; Smith, Kate; Che, Han

    2016-04-15

    Early warning systems are widely used to safeguard water security, but their effectiveness has raised many questions. To understand why conventional detection methods fail to identify contamination events, this study evaluates the performance of three contamination detection methods using data from a real contamination accident and two artificial datasets constructed using a widely applied contamination data construction approach. Results show that the Pearson correlation Euclidean distance (PE) based detection method performs better for real contamination incidents, while the Euclidean distance method (MED) and linear prediction filter (LPF) method are more suitable for detecting sudden spike-like variation. This analysis revealed why the conventional MED and LPF methods failed to identify existence of contamination events. The analysis also revealed that the widely used contamination data construction approach is misleading. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Comparative evaluation of surface porosities in conventional heat polymerized acrylic resin cured by water bath and microwave energy with microwavable acrylic resin cured by microwave energy

    PubMed Central

    Singh, Sunint; Palaskar, Jayant N.; Mittal, Sanjeev

    2013-01-01

    Background: Conventional heat cure poly methyl methacrylate (PMMA) is the most commonly used denture base resin despite having some short comings. Lengthy polymerization time being one of them and in order to overcome this fact microwave curing method was recommended. Unavailability of specially designed microwavable acrylic resin made it unpopular. Therefore, in this study, conventional heat cure PMMA was polymerized by microwave energy. Aim and Objectives: This study was designed to evaluate the surface porosities in PMMA cured by conventional water bath and microwave energy and compare it with microwavable acrylic resin cured by microwave energy. Materials and Methods: Wax samples were obtained by pouring molten wax into a metal mold of 25 mm × 12 mm × 3 mm dimensions. These samples were divided into three groups namely C, CM, and M. Group C denotes conventional heat cure PMMA cured by water bath method, CM denotes conventional heat cure PMMA cured by microwave energy, M denotes specially designed microwavable acrylic denture base resin cured by microwave energy. After polymerization, each sample was scanned in three pre-marked areas for surface porosities using the optical microscope. As per the literature available, this instrument is being used for the first time to measure the porosity in acrylic resin. It is a reliable method of measuring area of surface pores. Portion of the sample being scanned is displayed on the computer and with the help of software area of each pore was measured and data were analyzed. Results: Conventional heat cure PMMA samples cured by microwave energy showed maximum porosities than the samples cured by conventional water bath method and microwavable acrylic resin cured by microwave energy. Higher percentage of porosities was statistically significant, but well within the range to be clinically acceptable. Conclusion: Within the limitations of this in-vitro study, conventional heat cure PMMA can be cured by microwave energy without compromising on its property such as surface porosity. PMID:24015000

  15. [Evaluation of a Computer-Aided Microscope System and Its Anti-Nuclear Antibody Test Kit for Indirect Immunofluorescence Assay].

    PubMed

    Hayashi, Nobuhide; Saegusa, Jun; Uto, Kenichi; Oyabu, Chinami; Saito, Toshiharu; Sato, Itsuko; Kawano, Seiji; Kumagai, Shunichi

    2016-02-01

    Antinuclear antibody (ANA) testing is indispensable for diagnosing and understanding clinical conditions of autoimmune diseases. The indirect immunofluorescence assay (IFA) is the gold standard for ANA screening, and it can detect more than 100 different antibodies, such as anti-PCNA as well as anti-cytoplasmic antibodies. However, complicated procedures of conventional IFA and visual interpretation require highly skilled laboratory staff. This study evaluates the capability, characteristics, and applicability of the recently developed ANA detection system (EUROPattern Cosmic IFA System, EPA) using HEp20-10 cells and the automated pattern recognition microscope. Findings using EPA and conventional methods were compared in 282 sera obtained from connective tissue disease patients and 250 sera from healthy individuals. The concordance of the positivity rate, antibody titer (within +/- 1 tube difference), and the accurate recognition rate of ANA patterns between the automated EPA method and the microscopic judgement of the EPA image by eye was 98.9, 97.4, and 55.3%, respectively. The EPA method showed concordance of the positivity rate as high as 93.3% and concordance of the antibody titer as high as 94.0% (within +/- 1 titer) compared with the conventional method. Regarding the four typical patterns of ANA (homogeneous, speckled, nucleolar, and centromere), large differences between the EPA and conventional methods were not observed, and the rate of concordance between the final EPA result and the conventional method was from 94.1 to 100%. The positivity rate of ANA using the EPA and conventional methods showed marked agreement among the six connective tissue diseases (SLE, MCTD, SSc, PM/DM, and SS) and healthy individuals. Although the EPA system is not considered a complete system and laboratory staff should verify the results, it is a useful system for routine ANA analysis because it contributes to ANA standardization and an efficient workflow.

  16. Interim reliability evaluation program, Browns Ferry fault trees

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stewart, M.E.

    1981-01-01

    An abbreviated fault tree method is used to evaluate and model Browns Ferry systems in the Interim Reliability Evaluation programs, simplifying the recording and displaying of events, yet maintaining the system of identifying faults. The level of investigation is not changed. The analytical thought process inherent in the conventional method is not compromised. But the abbreviated method takes less time, and the fault modes are much more visible.

  17. [An improved medical image fusion algorithm and quality evaluation].

    PubMed

    Chen, Meiling; Tao, Ling; Qian, Zhiyu

    2009-08-01

    Medical image fusion is of very important value for application in medical image analysis and diagnosis. In this paper, the conventional method of wavelet fusion is improved,so a new algorithm of medical image fusion is presented and the high frequency and low frequency coefficients are studied respectively. When high frequency coefficients are chosen, the regional edge intensities of each sub-image are calculated to realize adaptive fusion. The choice of low frequency coefficient is based on the edges of images, so that the fused image preserves all useful information and appears more distinctly. We apply the conventional and the improved fusion algorithms based on wavelet transform to fuse two images of human body and also evaluate the fusion results through a quality evaluation method. Experimental results show that this algorithm can effectively retain the details of information on original images and enhance their edge and texture features. This new algorithm is better than the conventional fusion algorithm based on wavelet transform.

  18. A probability-based multi-cycle sorting method for 4D-MRI: A simulation study.

    PubMed

    Liang, Xiao; Yin, Fang-Fang; Liu, Yilin; Cai, Jing

    2016-12-01

    To develop a novel probability-based sorting method capable of generating multiple breathing cycles of 4D-MRI images and to evaluate performance of this new method by comparing with conventional phase-based methods in terms of image quality and tumor motion measurement. Based on previous findings that breathing motion probability density function (PDF) of a single breathing cycle is dramatically different from true stabilized PDF that resulted from many breathing cycles, it is expected that a probability-based sorting method capable of generating multiple breathing cycles of 4D images may capture breathing variation information missing from conventional single-cycle sorting methods. The overall idea is to identify a few main breathing cycles (and their corresponding weightings) that can best represent the main breathing patterns of the patient and then reconstruct a set of 4D images for each of the identified main breathing cycles. This method is implemented in three steps: (1) The breathing signal is decomposed into individual breathing cycles, characterized by amplitude, and period; (2) individual breathing cycles are grouped based on amplitude and period to determine the main breathing cycles. If a group contains more than 10% of all breathing cycles in a breathing signal, it is determined as a main breathing pattern group and is represented by the average of individual breathing cycles in the group; (3) for each main breathing cycle, a set of 4D images is reconstructed using a result-driven sorting method adapted from our previous study. The probability-based sorting method was first tested on 26 patients' breathing signals to evaluate its feasibility of improving target motion PDF. The new method was subsequently tested for a sequential image acquisition scheme on the 4D digital extended cardiac torso (XCAT) phantom. Performance of the probability-based and conventional sorting methods was evaluated in terms of target volume precision and accuracy as measured by the 4D images, and also the accuracy of average intensity projection (AIP) of 4D images. Probability-based sorting showed improved similarity of breathing motion PDF from 4D images to reference PDF compared to single cycle sorting, indicated by the significant increase in Dice similarity coefficient (DSC) (probability-based sorting, DSC = 0.89 ± 0.03, and single cycle sorting, DSC = 0.83 ± 0.05, p-value <0.001). Based on the simulation study on XCAT, the probability-based method outperforms the conventional phase-based methods in qualitative evaluation on motion artifacts and quantitative evaluation on tumor volume precision and accuracy and accuracy of AIP of the 4D images. In this paper the authors demonstrated the feasibility of a novel probability-based multicycle 4D image sorting method. The authors' preliminary results showed that the new method can improve the accuracy of tumor motion PDF and the AIP of 4D images, presenting potential advantages over the conventional phase-based sorting method for radiation therapy motion management.

  19. Method for thermal and structural evaluation of shallow intense-beam deposition in matter

    NASA Astrophysics Data System (ADS)

    Pilan Zanoni, André

    2018-05-01

    The projected range of high-intensity proton and heavy-ion beams at energies below a few tens of MeV/A in matter can be as short as a few micrometers. For the evaluation of temperature and stresses from a shallow beam energy deposition in matter conventional numerical 3D models require minuscule element sizes for acceptable element aspect ratio as well as extremely short time steps for numerical convergence. In order to simulate energy deposition using a manageable number of elements this article presents a method using layered elements. This method is applied to beam stoppers and accidental intense-beam impact onto UHV sector valves. In those cases the thermal results from the new method are congruent to those from conventional solid-element and adiabatic models.

  20. The application of intraoperative transit time flow measurement to accurately assess anastomotic quality in sequential vein grafting

    PubMed Central

    Yu, Yang; Zhang, Fan; Gao, Ming-Xin; Li, Hai-Tao; Li, Jing-Xing; Song, Wei; Huang, Xin-Sheng; Gu, Cheng-Xiong

    2013-01-01

    OBJECTIVES Intraoperative transit time flow measurement (TTFM) is widely used to assess anastomotic quality in coronary artery bypass grafting (CABG). However, in sequential vein grafting, the flow characteristics collected by the conventional TTFM method are usually associated with total graft flow and might not accurately indicate the quality of every distal anastomosis in a sequential graft. The purpose of our study was to examine a new TTFM method that could assess the quality of each distal anastomosis in a sequential graft more reliably than the conventional TTFM approach. METHODS Two TTFM methods were tested in 84 patients who underwent sequential saphenous off-pump CABG in Beijing An Zhen Hospital between April and August 2012. In the conventional TTFM method, normal blood flow in the sequential graft was maintained during the measurement, and the flow probe was placed a few centimetres above the anastomosis to be evaluated. In the new method, blood flow in the sequential graft was temporarily reduced during the measurement by placing an atraumatic bulldog clamp at the graft a few centimetres distal to the anastomosis to be evaluated, while the position of the flow probe remained the same as in the conventional method. This new TTFM method was named the flow reduction TTFM. Graft flow parameters measured by both methods were compared. RESULTS Compared with the conventional TTFM, the flow reduction TTFM resulted in significantly lower mean graft blood flow (P < 0.05); in contrast, yielded significantly higher pulsatility index (P < 0.05). Diastolic filling was not significantly different between the two methods and was >50% in both cases. Interestingly, the flow reduction TTFM identified two defective middle distal anastomoses that the conventional TTFM failed to detect. Graft flows near the defective distal anastomoses were improved substantially after revision. CONCLUSIONS In this study, we found that temporary reduction of graft flow during TTFM seemed to enhance the sensitivity of TTFM to less-than-critical anastomotic defects in a sequential graft and to improve the overall accuracy of the intraoperative assessment of anastomotic quality in sequential vein grafting. PMID:24000314

  1. Assessment of cerebral venous sinus thrombosis using T2*-weighted gradient echo magnetic resonance imaging sequences

    PubMed Central

    Bidar, Fatemeh; Faeghi, Fariborz; Ghorbani, Askar

    2016-01-01

    Background: The purpose of this study is to demonstrate the advantages of gradient echo (GRE) sequences in the detection and characterization of cerebral venous sinus thrombosis compared to conventional magnetic resonance sequences. Methods: A total of 17 patients with cerebral venous thrombosis (CVT) were evaluated using different magnetic resonance imaging (MRI) sequences. The MRI sequences included T1-weighted spin echo (SE) imaging, T*2-weighted turbo SE (TSE), fluid attenuated inversion recovery (FLAIR), T*2-weighted conventional GRE, and diffusion weighted imaging (DWI). MR venography (MRV) images were obtained as the golden standard. Results: Venous sinus thrombosis was best detectable in T*2-weighted conventional GRE sequences in all patients except in one case. Venous thrombosis was undetectable in DWI. T*2-weighted GRE sequences were superior to T*2-weighted TSE, T1-weighted SE, and FLAIR. Enhanced MRV was successful in displaying the location of thrombosis. Conclusion: T*2-weighted conventional GRE sequences are probably the best method for the assessment of cerebral venous sinus thrombosis. The mentioned method is non-invasive; therefore, it can be employed in the clinical evaluation of cerebral venous sinus thrombosis. PMID:27326365

  2. A review of MRI evaluation of demyelination in cuprizone murine model

    NASA Astrophysics Data System (ADS)

    Krutenkova, E.; Pan, E.; Khodanovich, M.

    2015-11-01

    The cuprizone mouse model of non-autoimmune demyelination reproduces some phenomena of multiple sclerosis and is appropriate for validation and specification of a new method of non-invasive diagnostics. In the review new data which are collected using the new MRI method are compared with one or more conventional MRI tools. Also the paper reviewed the validation of MRI approaches using histological or immunohistochemical methods. Luxol fast blue histological staining and myelin basic protein immunostaining is widespread. To improve the accuracy of non-invasive conventional MRI, multimodal scanning could be applied. The new quantitative MRI method of fast mapping of the macromolecular proton fraction is a reliable biomarker of myelin in the brain and can be used for research of demyelination in animals. To date, a validation of MPF method on the CPZ mouse model of demyelination is not performed, although this method is probably the best way to evaluate demyelination using MRI.

  3. Evaluation of the marginal fit of single-unit, complete-coverage ceramic restorations fabricated after digital and conventional impressions: A systematic review and meta-analysis.

    PubMed

    Tsirogiannis, Panagiotis; Reissmann, Daniel R; Heydecke, Guido

    2016-09-01

    In existing published reports, some studies indicate the superiority of digital impression systems in terms of the marginal accuracy of ceramic restorations, whereas others show that the conventional method provides restorations with better marginal fit than fully digital fabrication. Which impression method provides the lowest mean values for marginal adaptation is inconclusive. The findings from those studies cannot be easily generalized, and in vivo studies that could provide valid and meaningful information are limited in the existing publications. The purpose of this study was to systematically review existing reports and evaluate the marginal fit of ceramic single-tooth restorations after either digital or conventional impression methods by combining the available evidence in a meta-analysis. The search strategy for this systematic review of the publications was based on a Population, Intervention, Comparison, and Outcome (PICO) framework. For the statistical analysis, the mean marginal fit values of each study were extracted and categorized according to the impression method to calculate the mean value, together with the 95% confidence intervals (CI) of each category, and to evaluate the impact of each impression method on the marginal adaptation by comparing digital and conventional techniques separately for in vitro and in vivo studies. Twelve studies were included in the meta-analysis from the 63 identified records after database searching. For the in vitro studies, where ceramic restorations were fabricated after conventional impressions, the mean value of the marginal fit was 58.9 μm (95% CI: 41.1-76.7 μm), whereas after digital impressions, it was 63.3 μm (95% CI: 50.5-76.0 μm). In the in vivo studies, the mean marginal discrepancy of the restorations after digital impressions was 56.1 μm (95% CI: 46.3-65.8 μm), whereas after conventional impressions, it was 79.2 μm (95% CI: 59.6-98.9 μm) No significant difference was observed regarding the marginal discrepancy of single-unit ceramic restorations fabricated after digital or conventional impressions. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. Aquifer water abundance evaluation using a fuzzy- comprehensive weighting method

    NASA Astrophysics Data System (ADS)

    Wei, Z.

    2016-08-01

    Aquifer water abundance evaluation is a highly relevant issue that has been researched for many years. Despite prior research, problems with the conventional evaluation method remain. This paper establishes an aquifer water abundance evaluation method that combines fuzzy evaluation with a comprehensive weighting method to overcome both the subjectivity and lack of conformity in determining weight by pure data analysis alone. First, this paper introduces the principle of a fuzzy-comprehensive weighting method. Second, the example of well field no. 3 (of a coalfield) is used to illustrate the method's process. The evaluation results show that this method is can more suitably meet the real requirements of aquifer water abundance assessment, leading to more precise and accurate evaluations. Ultimately, this paper provides a new method for aquifer water abundance evaluation.

  5. Clinical evaluation of a chemomechanical method for caries removal in children and adolescents.

    PubMed

    Peric, Tamara; Markovic, Dejan; Petrovic, Bojan

    2009-01-01

    The purpose of this study was to make a clinical comparison of the chemomechanical method for caries removal and the conventional rotary instruments technique when used in children and adolescents. The study comprised 120 patients aged 3-17 years randomized into two groups: caries were removed chemomechanically in 60 patients and 60 patients received conventional treatment with rotary instruments. The outcome variables were: clinically complete caries removal, pain during caries removal, need for local anesthesia, treatment time, preferences of patients, and clinical success of the restorations during the 12-month evaluation period. Complete caries removal was achieved in 92% of chemomechanically treated teeth and in all teeth treated with rotary instruments (p>0.05). The chemomechanical method significantly reduced the need for local anesthesia (p<0.001). Eighty-five percent of patients treated with Carisolv and 47% treated with rotary instruments were satisfied with the treatment (p<0.05). The mean time for chemomechanical caries removal was 11.2 ± 3.3 min and 5.2 ± 2.8 min for caries removal with rotary instruments (p<0.001). At the end of the 12-month evaluation period, there was no observed influence of the caries removal method on the survival of the restorations. The chemomechanical caries removal technique is an adequate alternative to the conventional rotary instruments method and is advantageous in pediatric dentistry.

  6. Role of conventional radiology and MRi defecography of pelvic floor hernias

    PubMed Central

    2013-01-01

    Background Purpose of the study is to define the role of conventional radiology and MRI in the evaluation of pelvic floor hernias in female pelvic floor disorders. Methods A MEDLINE and PubMed search was performed for journals before March 2013 with MeSH major terms 'MR Defecography' and 'pelvic floor hernias'. Results The prevalence of pelvic floor hernias at conventional radiology was higher if compared with that at MRI. Concerning the hernia content, there were significantly more enteroceles and sigmoidoceles on conventional radiology than on MRI, whereas, in relation to the hernia development modalities, the prevalence of elytroceles, edroceles, and Douglas' hernias at conventional radiology was significantly higher than that at MRI. Conclusions MRI shows lower sensitivity than conventional radiology in the detection of pelvic floor hernias development. The less-invasive MRI may have a role in a better evaluation of the entire pelvic anatomy and pelvic organ interaction especially in patients with multicompartmental defects, planned for surgery. PMID:24267789

  7. Effectiveness of Video Demonstration over Conventional Methods in Teaching Osteology in Anatomy.

    PubMed

    Viswasom, Angela A; Jobby, Abraham

    2017-02-01

    Technology and its applications are the most happening things in the world. So, is it in the field of medical education. This study was an evaluation of whether the conventional methods can compete with the test of technology. A comparative study of traditional method of teaching osteology in human anatomy with an innovative visual aided method. The study was conducted on 94 students admitted to MBBS 2014 to 2015 batch of Travancore Medical College. The students were divided into two academically validated groups. They were taught using conventional and video demonstrational techniques in a systematic manner. Post evaluation tests were conducted. Analysis of the mark pattern revealed that the group taught using traditional method scored better when compared to the visual aided method. Feedback analysis showed that, the students were able to identify bony features better with clear visualisation and three dimensional view when taught using the video demonstration method. The students identified visual aided method as the more interesting one for learning which helped them in applying the knowledge gained. In most of the questions asked, the two methods of teaching were found to be comparable on the same scale. As the study ends, we discover that, no new technique can be substituted for time tested techniques of teaching and learning. The ideal method would be incorporating newer multimedia techniques into traditional classes.

  8. Nondestructive Evaluation of the Friction Weld Process on 2195/2219 Grade Aluminum

    NASA Technical Reports Server (NTRS)

    Suits, Michael W.; Clark, Linda S.; Cox, Dwight E.

    1999-01-01

    In 1996, NASA's Marshall Space Flight Center began an ambitious program designed to find alternative methods of repairing conventional TIG (Tungsten Inert Gas) welds and VPPA (Variable Polarity Plasma Arc) welds on the Space Shuttle External Tank without producing additional heat-related anomalies or conditions. Therefore, a relatively new method, invented by The Welding Institute (TWI) in Cambridge, England, called Friction Stir Welding (FSW), was investigated for use in this application, as well as being used potentially as an initial weld process. As with the conventional repair welding processes, nondestructive evaluation (NDE) plays a crucial role in the verification of these repairs. Since it was feared that conventional NDE might have trouble with this type of weld structure (due to shape of nugget, grain structure, etc.) it was imperative that a complete study be performed to address the adequacy of the NDE process. This paper summarizes that process.

  9. Comparison of Conventional Versus Spiral Computed Tomography with Three Dimensional Reconstruction in Chronic Otitis Media with Ossicular Chain Destruction.

    PubMed

    Naghibi, Saeed; Seifirad, Sirous; Adami Dehkordi, Mahboobeh; Einolghozati, Sasan; Ghaffarian Eidgahi Moghadam, Nafiseh; Akhavan Rezayat, Amir; Seifirad, Soroush

    2016-01-01

    Chronic otitis media (COM) can be treated with tympanoplasty with or without mastoidectomy. In patients who have undergone middle ear surgery, three-dimensional spiral computed tomography (CT) scan plays an important role in optimizing surgical planning. This study was performed to compare the findings of three-dimensional reconstructed spiral and conventional CT scan of ossicular chain study in patients with COM. Fifty patients enrolled in the study underwent plane and three dimensional CT scan (PHILIPS-MX 8000). Ossicles changes, mastoid cavity, tympanic cavity, and presence of cholesteatoma were evaluated. Results of the two methods were then compared and interpreted by a radiologist, recorded in questionnaires, and analyzed. Logistic regression test and Kappa coefficient of agreement were used for statistical analyses. Sixty two ears with COM were found in physical examination. A significant difference was observed between the findings of the two methods in ossicle erosion (11.3% in conventional CT vs. 37.1% in spiral CT, P = 0.0001), decrease of mastoid air cells (82.3% in conventional CT vs. 93.5% in spiral CT, P = 0.001), and tympanic cavity opacity (12.9% in conventional CT vs. 40.3% in spiral CT, P=0.0001). No significant difference was observed between the findings of the two methods in ossicle destruction (6.5% conventional CT vs. 56.4% in spiral CT, P = 0.125), and presence of cholesteatoma (3.2% in conventional CT vs. 42% in spiral CT, P = 0.172). In this study, spiral CT scan demonstrated ossicle dislocation in 9.6%, decrease of mastoid air cells in 4.8%, and decrease of volume in the tympanic cavity in 1.6%; whereas, none of these findings were reported in the patients' conventional CT scans. Spiral-CT scan is superior to conventional CT in the diagnosis of lesions in COM before operation. It can be used for detailed evaluation of ossicular chain in such patients.

  10. Multi-laboratory evaluations of the performance of Catellicoccus marimammalium PCR assays developed to target gull fecal sources

    EPA Science Inventory

    Here we report results from a multi-laboratory (n=11) evaluation of four different PCR methods targeting the 16S rRNA gene of Catellicoccus marimammalium used to detect fecal contamination from birds in coastal environments. The methods included conventional end-point PCR, a SYBR...

  11. An adaptive quantum mechanics/molecular mechanics method for the infrared spectrum of water: incorporation of the quantum effect between solute and solvent.

    PubMed

    Watanabe, Hiroshi C; Banno, Misa; Sakurai, Minoru

    2016-03-14

    Quantum effects in solute-solvent interactions, such as the many-body effect and the dipole-induced dipole, are known to be critical factors influencing the infrared spectra of species in the liquid phase. For accurate spectrum evaluation, the surrounding solvent molecules, in addition to the solute of interest, should be treated using a quantum mechanical method. However, conventional quantum mechanics/molecular mechanics (QM/MM) methods cannot handle free QM solvent molecules during molecular dynamics (MD) simulation because of the diffusion problem. To deal with this problem, we have previously proposed an adaptive QM/MM "size-consistent multipartitioning (SCMP) method". In the present study, as the first application of the SCMP method, we demonstrate the reproduction of the infrared spectrum of liquid-phase water, and evaluate the quantum effect in comparison with conventional QM/MM simulations.

  12. Factors influencing the results of faculty evaluation in Isfahan University of Medical Sciences.

    PubMed

    Kamali, Farahnaz; Yamani, Nikoo; Changiz, Tahereh; Zoubin, Fatemeh

    2018-01-01

    This study aimed to explore factors influencing the results of faculty member evaluation from the viewpoints of faculty members affiliated with Isfahan University of Medical Sciences, Isfahan, Iran. This qualitative study was done using a conventional content analysis method. Participants were faculty members of Isfahan University of Medical Sciences who, considering maximum variation in sampling, were chosen with a purposive sampling method. Semi-structured interviews were held with 11 faculty members until data saturation was reached. The interviews were transcribed verbatim and analyzed with conventional content analysis method for theme development. Further, the MAXQDA software was used for data management. The data analysis led to the development of two main themes, namely, "characteristics of the educational system" and "characteristics of the faculty member evaluation system." The first main theme consists of three categories, i.e. "characteristics of influential people in evaluation," "features of the courses," and "background characteristics." The other theme has the following as its categories: "evaluation methods," "evaluation tools," "evaluation process," and "application of evaluation results." Each category will have its subcategories. Many factors affect the evaluation of faculty members that should be taken into account by educational policymakers for improving the quality of the educational process. In addition to the factors that directly influence the educational system, methodological problems in the evaluation system need special attention.

  13. A Holistic Approach to Evaluating Vocational Education: Traditional Chinese Physicians (TCP) Model.

    ERIC Educational Resources Information Center

    Lee, Lung-Sheng; Chang, Liang-Te

    Conventional approaches to evaluating vocational education have often been criticized for failing to deal holistically with the institution or program being evaluated. Integrated quantitative and qualitative evaluation methods have documented benefits; therefore, it would be useful to consider possibility of developing a model for evaluating…

  14. Factors influencing the results of faculty evaluation in Isfahan University of Medical Sciences

    PubMed Central

    Kamali, Farahnaz; Yamani, Nikoo; Changiz, Tahereh; Zoubin, Fatemeh

    2018-01-01

    OBJECTIVE: This study aimed to explore factors influencing the results of faculty member evaluation from the viewpoints of faculty members affiliated with Isfahan University of Medical Sciences, Isfahan, Iran. MATERIALS AND METHODS: This qualitative study was done using a conventional content analysis method. Participants were faculty members of Isfahan University of Medical Sciences who, considering maximum variation in sampling, were chosen with a purposive sampling method. Semi-structured interviews were held with 11 faculty members until data saturation was reached. The interviews were transcribed verbatim and analyzed with conventional content analysis method for theme development. Further, the MAXQDA software was used for data management. RESULTS: The data analysis led to the development of two main themes, namely, “characteristics of the educational system” and “characteristics of the faculty member evaluation system.” The first main theme consists of three categories, i.e. “characteristics of influential people in evaluation,” “features of the courses,” and “background characteristics.” The other theme has the following as its categories: “evaluation methods,” “evaluation tools,” “evaluation process,” and “application of evaluation results.” Each category will have its subcategories. CONCLUSIONS: Many factors affect the evaluation of faculty members that should be taken into account by educational policymakers for improving the quality of the educational process. In addition to the factors that directly influence the educational system, methodological problems in the evaluation system need special attention. PMID:29417073

  15. Patch-based generation of a pseudo CT from conventional MRI sequences for MRI-only radiotherapy of the brain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andreasen, Daniel, E-mail: dana@dtu.dk; Van Leemput, Koen; Hansen, Rasmus H.

    Purpose: In radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, the information on electron density must be derived from the MRI scan by creating a so-called pseudo computed tomography (pCT). This is a nontrivial task, since the voxel-intensities in an MRI scan are not uniquely related to electron density. To solve the task, voxel-based or atlas-based models have typically been used. The voxel-based models require a specialized dual ultrashort echo time MRI sequence for bone visualization and the atlas-based models require deformable registrations of conventional MRI scans. In this study, we investigate the potential of amore » patch-based method for creating a pCT based on conventional T{sub 1}-weighted MRI scans without using deformable registrations. We compare this method against two state-of-the-art methods within the voxel-based and atlas-based categories. Methods: The data consisted of CT and MRI scans of five cranial RT patients. To compare the performance of the different methods, a nested cross validation was done to find optimal model parameters for all the methods. Voxel-wise and geometric evaluations of the pCTs were done. Furthermore, a radiologic evaluation based on water equivalent path lengths was carried out, comparing the upper hemisphere of the head in the pCT and the real CT. Finally, the dosimetric accuracy was tested and compared for a photon treatment plan. Results: The pCTs produced with the patch-based method had the best voxel-wise, geometric, and radiologic agreement with the real CT, closely followed by the atlas-based method. In terms of the dosimetric accuracy, the patch-based method had average deviations of less than 0.5% in measures related to target coverage. Conclusions: We showed that a patch-based method could generate an accurate pCT based on conventional T{sub 1}-weighted MRI sequences and without deformable registrations. In our evaluations, the method performed better than existing voxel-based and atlas-based methods and showed a promising potential for RT of the brain based only on MRI.« less

  16. A probability-based multi-cycle sorting method for 4D-MRI: A simulation study

    PubMed Central

    Liang, Xiao; Yin, Fang-Fang; Liu, Yilin; Cai, Jing

    2016-01-01

    Purpose: To develop a novel probability-based sorting method capable of generating multiple breathing cycles of 4D-MRI images and to evaluate performance of this new method by comparing with conventional phase-based methods in terms of image quality and tumor motion measurement. Methods: Based on previous findings that breathing motion probability density function (PDF) of a single breathing cycle is dramatically different from true stabilized PDF that resulted from many breathing cycles, it is expected that a probability-based sorting method capable of generating multiple breathing cycles of 4D images may capture breathing variation information missing from conventional single-cycle sorting methods. The overall idea is to identify a few main breathing cycles (and their corresponding weightings) that can best represent the main breathing patterns of the patient and then reconstruct a set of 4D images for each of the identified main breathing cycles. This method is implemented in three steps: (1) The breathing signal is decomposed into individual breathing cycles, characterized by amplitude, and period; (2) individual breathing cycles are grouped based on amplitude and period to determine the main breathing cycles. If a group contains more than 10% of all breathing cycles in a breathing signal, it is determined as a main breathing pattern group and is represented by the average of individual breathing cycles in the group; (3) for each main breathing cycle, a set of 4D images is reconstructed using a result-driven sorting method adapted from our previous study. The probability-based sorting method was first tested on 26 patients’ breathing signals to evaluate its feasibility of improving target motion PDF. The new method was subsequently tested for a sequential image acquisition scheme on the 4D digital extended cardiac torso (XCAT) phantom. Performance of the probability-based and conventional sorting methods was evaluated in terms of target volume precision and accuracy as measured by the 4D images, and also the accuracy of average intensity projection (AIP) of 4D images. Results: Probability-based sorting showed improved similarity of breathing motion PDF from 4D images to reference PDF compared to single cycle sorting, indicated by the significant increase in Dice similarity coefficient (DSC) (probability-based sorting, DSC = 0.89 ± 0.03, and single cycle sorting, DSC = 0.83 ± 0.05, p-value <0.001). Based on the simulation study on XCAT, the probability-based method outperforms the conventional phase-based methods in qualitative evaluation on motion artifacts and quantitative evaluation on tumor volume precision and accuracy and accuracy of AIP of the 4D images. Conclusions: In this paper the authors demonstrated the feasibility of a novel probability-based multicycle 4D image sorting method. The authors’ preliminary results showed that the new method can improve the accuracy of tumor motion PDF and the AIP of 4D images, presenting potential advantages over the conventional phase-based sorting method for radiation therapy motion management. PMID:27908178

  17. Glycoalkaloid, phenolic, and flavonoid content and antioxidative activities of conventional (nonorganic) and organic potato peel powders from commercial Gold, Red, and Russet Potatoes

    USDA-ARS?s Scientific Manuscript database

    The content of glycoalkaloids a-chaconine and a-solanine, individual and total phenolics compounds, and total flavonoids for three peels prepared from conventional and three from organic commercial potatoes as well antioxidant activities using three different methods were evaluated. Glycoalkaloids ...

  18. Conventional forceps or hot biopsy: comparative study of two methods in diagnosis of endobronchial lesions.

    PubMed

    Jabbari, Hamidreza; Fakhri, Mohammad; Lotfaliani, Mojtaba; Kiani, Arda

    2013-01-01

    It is suggested that hot electrocoagulation-enabled forceps (hot biopsy) may reduce hemorrhage risk after the biopsy in endobronchial tumors. The main concern in this method is possible reduction of the specimen's quality. To compare the procedure related hemorrhage with hot biopsy and conventional forceps biopsy and the diagnostic quality of the obtained specimens with either technique. In this prospective study, assessment of the biopsy samples and quantity of hemorrhage were done in a blind fashion. At first, for each patient a definite clinical diagnosis was made based on pathologic examination of all available samples, clinical data, and imaging findings. Then, second pathologist reviewed all samples to evaluate the quality of the samples. A total of 36 patients with endobronchial lesions were included in this study. Definite diagnosis was made in 83% of the patients. Diagnostic yield of the two methods were not statistically different, while the mean hemorrhage grades of all hot biopsy protocols were significantly lower as compared to that of conventional biopsy (p=0.003, p<0.001 and p<0.001 for 10,20and40 voltages respectively). No significant difference was detected between the qualities of specimens obtained by hot biopsy methods in comparison with conventional biopsy (p>0.05 for all three voltages). Hot biopsy can be a valuable alternative to forceps biopsy in evaluating endobronchial lesions.

  19. Ultrasonic and radiographic evaluation of advanced aerospace materials: Ceramic composites

    NASA Technical Reports Server (NTRS)

    Generazio, Edward R.

    1990-01-01

    Two conventional nondestructive evaluation techniques were used to evaluate advanced ceramic composite materials. It was shown that neither ultrasonic C-scan nor radiographic imaging can individually provide sufficient data for an accurate nondestructive evaluation. Both ultrasonic C-scan and conventional radiographic imaging are required for preliminary evaluation of these complex systems. The material variations that were identified by these two techniques are porosity, delaminations, bond quality between laminae, fiber alignment, fiber registration, fiber parallelism, and processing density flaws. The degree of bonding between fiber and matrix cannot be determined by either of these methods. An alternative ultrasonic technique, angular power spectrum scanning (APSS) is recommended for quantification of this interfacial bond.

  20. Evaluation of direct and indirect additive manufacture of maxillofacial prostheses.

    PubMed

    Eggbeer, Dominic; Bibb, Richard; Evans, Peter; Ji, Lu

    2012-09-01

    The efficacy of computer-aided technologies in the design and manufacture of maxillofacial prostheses has not been fully proven. This paper presents research into the evaluation of direct and indirect additive manufacture of a maxillofacial prosthesis against conventional laboratory-based techniques. An implant/magnet-retained nasal prosthesis case from a UK maxillofacial unit was selected as a case study. A benchmark prosthesis was fabricated using conventional laboratory-based techniques for comparison against additive manufactured prostheses. For the computer-aided workflow, photogrammetry, computer-aided design and additive manufacture (AM) methods were evaluated in direct prosthesis body fabrication and indirect production using an additively manufactured mould. Qualitative analysis of position, shape, colour and edge quality was undertaken. Mechanical testing to ISO standards was also used to compare the silicone rubber used in the conventional prosthesis with the AM material. Critical evaluation has shown that utilising a computer-aided work-flow can produce a prosthesis body that is comparable to that produced using existing best practice. Technical limitations currently prevent the direct fabrication method demonstrated in this paper from being clinically viable. This research helps prosthesis providers understand the application of a computer-aided approach and guides technology developers and researchers to address the limitations identified.

  1. Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis.

    PubMed

    Lima, Ana Paula Barbosa; Vitti, Rafael Pino; Amaral, Marina; Neves, Ana Christina Claro; da Silva Concilio, Lais Regiane

    2018-04-01

    This study evaluated the dimensional stability of a complete-arch prosthesis processed by conventional method in water bath or microwave energy and polymerized by two different curing cycles. Forty maxillary complete-arch prostheses were randomly divided into four groups (n = 10): MW1 - acrylic resin cured by one microwave cycle; MW2 - acrylic resin cured by two microwave cycles: WB1 - conventional acrylic resin polymerized using one curing cycle in a water bath; WB2 - conventional acrylic resin polymerized using two curing cycles in a water bath. For evaluation of dimensional stability, occlusal vertical dimension (OVD) and area of contact points were measured in two different measurement times: before and after the polymerization method. A digital caliper was used for OVD measurement. Occlusal contact registration strips were used between maxillary and mandibular dentures to measure the contact points. The images were measured using the software IpWin32, and the differences before and after the polymerization methods were calculated. The data were statistically analyzed using the one-way ANOVA and Tukey test (α = .05). he results demonstrated significant statistical differences for OVD between different measurement times for all groups. MW1 presented the highest OVD values, while WB2 had the lowest OVD values ( P <.05). No statistical differences were found for area of contact points among the groups ( P =.7150). The conventional acrylic resin polymerized using two curing cycles in a water bath led to less difference in OVD of complete-arch prosthesis.

  2. Evaluation of the marginal fit of metal copings fabricated on three different marginal designs using conventional and accelerated casting techniques: an in vitro study.

    PubMed

    Vaidya, Sharad; Parkash, Hari; Bhargava, Akshay; Gupta, Sharad

    2014-01-01

    Abundant resources and techniques have been used for complete coverage crown fabrication. Conventional investing and casting procedures for phosphate-bonded investments require a 2- to 4-h procedure before completion. Accelerated casting techniques have been used, but may not result in castings with matching marginal accuracy. The study measured the marginal gap and determined the clinical acceptability of single cast copings invested in a phosphate-bonded investment with the use of conventional and accelerated methods. One hundred and twenty cast coping samples were fabricated using conventional and accelerated methods, with three finish lines: Chamfer, shoulder and shoulder with bevel. Sixty copings were prepared with each technique. Each coping was examined with a stereomicroscope at four predetermined sites and measurements of marginal gaps were documented for each. A master chart was prepared for all the data and was analyzed using Statistical Package for the Social Sciences version. Evidence of marginal gap was then evaluated by t-test. Analysis of variance and Post-hoc analysis were used to compare two groups as well as to make comparisons between three subgroups . Measurements recorded showed no statistically significant difference between conventional and accelerated groups. Among the three marginal designs studied, shoulder with bevel showed the best marginal fit with conventional as well as accelerated casting techniques. Accelerated casting technique could be a vital alternative to the time-consuming conventional casting technique. The marginal fit between the two casting techniques showed no statistical difference.

  3. Generalized Reich-Moore R-matrix approximation

    NASA Astrophysics Data System (ADS)

    Arbanas, Goran; Sobes, Vladimir; Holcomb, Andrew; Ducru, Pablo; Pigni, Marco; Wiarda, Dorothea

    2017-09-01

    A conventional Reich-Moore approximation (RMA) of R-matrix is generalized into a manifestly unitary form by introducing a set of resonant capture channels treated explicitly in a generalized, reduced R-matrix. A dramatic reduction of channel space witnessed in conventional RMA, from Nc × Nc full R-matrix to Np × Np reduced R-matrix, where Nc = Np + Nγ, Np and Nγ denoting the number of particle and γ-ray channels, respectively, is due to Np < Nγ. A corresponding reduction of channel space in generalized RMA (GRMA) is from Nc × Nc full R-matrix to N × N, where N = Np + N, and where N is the number of capture channels defined in GRMA. We show that N = Nλ where Nλ is the number of R-matrix levels. This reduction in channel space, although not as dramatic as in the conventional RMA, could be significant for medium and heavy nuclides where N < Nγ. The resonant capture channels defined by GRMA accommodate level-level interference (via capture channels) neglected in conventional RMA. The expression for total capture cross section in GRMA is formally equal to that of the full Nc × NcR-matrix. This suggests that GRMA could yield improved nuclear data evaluations in the resolved resonance range at a cost of introducing N(N - 1)/2 resonant capture width parameters relative to conventional RMA. Manifest unitarity of GRMA justifies a method advocated by Fröhner and implemented in the SAMMY nuclear data evaluation code for enforcing unitarity of conventional RMA. Capture widths of GRMA are exactly convertible into alternative R-matrix parameters via Brune tranform. Application of idealized statistical methods to GRMA shows that variance among conventional RMA capture widths in extant RMA evaluations could be used to estimate variance among off-diagonal elements neglected by conventional RMA. Significant departure of capture widths from an idealized distribution may indicate the presence of underlying doorway states.

  4. Evaluation of spray application methods for navel orangeworm control in almonds.

    PubMed

    Markle, James C; Niederholzer, Franz Ja; Zalom, Frank G

    2016-12-01

    Gear Up/Throttle Down (GUTD) and Inward Only strategies represent potential alternatives to conventional airblast applications to reduce spray drift. This study evaluates Inward Only and a modified version of GUTD in almonds, the largest US tree crop, at the recommended hull split treatment timing for control of navel orangeworm (NOW), the key almond insect pest. Conventional treatment produced the most drift (15.6% of total bifenthrin load), while the GUTD and Inward Only treatments produced only 7.6 and 9.7% respectively. For all methods, 92-94% of the drift was found in the first 15.2 m downwind of the orchard. NOW control was lower for the Inward Only treatment compared with the GUTD and conventional treatments. NOW control was consistently lower at 4.88 m height relative to 2.44 m in all treatments, reflecting the reduced deposition higher in the tree canopy recorded in deposition samples. While Inward Only treatments reduced spray drift relative to the conventional application method, poorer control of NOW, the key insect pest of almonds, in the Inward Only treatment would likely limit its voluntary use by growers. However, GUTD holds promise for use at the hull split treatment timing to address spray drift. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  5. METHOD FOR THE SUPERCRITICAL FLUID EXTRACTION OF SOILS/SEDIMENTS

    EPA Science Inventory

    Supercritical fluid extraction has been publicized as an extraction method which has several advantages over conventional methods, and it is expected to result in substantial cost and labor savings. This study was designed to evaluate the feasibility of using supercritical fluid ...

  6. Evaluation of bearing capacity of piles from cone penetration test data.

    DOT National Transportation Integrated Search

    2007-12-01

    A statistical analysis and ranking criteria were used to compare the CPT methods and the conventional alpha design method. Based on the results, the de Ruiter/Beringen and LCPC methods showed the best capability in predicting the measured load carryi...

  7. Quantitative Evaluation of Heavy Duty Machine Tools Remanufacturing Based on Modified Catastrophe Progression Method

    NASA Astrophysics Data System (ADS)

    shunhe, Li; jianhua, Rao; lin, Gui; weimin, Zhang; degang, Liu

    2017-11-01

    The result of remanufacturing evaluation is the basis for judging whether the heavy duty machine tool can remanufacture in the EOL stage of the machine tool lifecycle management.The objectivity and accuracy of evaluation is the key to the evaluation method.In this paper, the catastrophe progression method is introduced into the quantitative evaluation of heavy duty machine tools’ remanufacturing,and the results are modified by the comprehensive adjustment method,which makes the evaluation results accord with the standard of human conventional thinking.Using the catastrophe progression method to establish the heavy duty machine tools’ quantitative evaluation model,to evaluate the retired TK6916 type CNC floor milling-boring machine’s remanufacturing.The evaluation process is simple,high quantification,the result is objective.

  8. A review of the application of propensity score methods yielded increasing use, advantages in specific settings, but not substantially different estimates compared with conventional multivariable methods

    PubMed Central

    Stürmer, Til; Joshi, Manisha; Glynn, Robert J.; Avorn, Jerry; Rothman, Kenneth J.; Schneeweiss, Sebastian

    2006-01-01

    Objective Propensity score analyses attempt to control for confounding in non-experimental studies by adjusting for the likelihood that a given patient is exposed. Such analyses have been proposed to address confounding by indication, but there is little empirical evidence that they achieve better control than conventional multivariate outcome modeling. Study design and methods Using PubMed and Science Citation Index, we assessed the use of propensity scores over time and critically evaluated studies published through 2003. Results Use of propensity scores increased from a total of 8 papers before 1998 to 71 in 2003. Most of the 177 published studies abstracted assessed medications (N=60) or surgical interventions (N=51), mainly in cardiology and cardiac surgery (N=90). Whether PS methods or conventional outcome models were used to control for confounding had little effect on results in those studies in which such comparison was possible. Only 9 out of 69 studies (13%) had an effect estimate that differed by more than 20% from that obtained with a conventional outcome model in all PS analyses presented. Conclusions Publication of results based on propensity score methods has increased dramatically, but there is little evidence that these methods yield substantially different estimates compared with conventional multivariable methods. PMID:16632131

  9. Comparison between Bactec Peds Plus F Broth and Conventional Medium for Vitreous Culture.

    PubMed

    Tabatabaei, Seyed Ali; Tabatabaei, Seyed Mehdi; Soleimani, Mohammad; Hejrati, Bahman; Mirshahi, Ahmad; Khadabandeh, Alireza; Ahmadraji, Aliasghar; Valipour, Niloofar

    2018-05-10

    To evaluate the yield of Bactec Peds Plus F broth for vitreous sample culture in cases with infectious endophthalmitis in comparison to conventional medium. Consecutive cases of clinically suspected endophthalmitis were prospectively enrolled in this study. Cultures of the vitreous sample were performed in both Bactec Peds Plus F broth and conventional mediums. Forty eyes of 40 patients who were clinically suspected of infectious endophthalmitis with different etiologies were enrolled in this study. The positive culture yield was 50% and 35% in Bactec Peds Plus F broth and conventional mediums, respectively (p = 0.07). The result of Bactec group was not significantly different among patients who had a history of intravitreal antibiotic injection (p > 0.05) (Table 2). However, results of the conventional method were significantly negative in the previous intravitreal antibiotic injection group (p = 0.02). There was no correlation between the methods of vitreous sampling in both culture methods. Although the difference between two culture methods was not statistically significant in this study, Bactec Peds Plus F broth showed higher positive culture yield in patients with a history of intravitreal antibiotic injection.

  10. Comparison of specimen adequacy and smear quality in oral smears prepared by manual liquid-based cytology and conventional methods

    PubMed Central

    Shukla, Surabhi; Einstein, A; Shukla, Abhilasha; Mishra, Deepika

    2015-01-01

    Background: Liquid-based cytology (LBC), recommended in the mass screening of potentially malignant cervical and oral lesions, suffers from high cost owing to the use of expensive automated devices and materials. Considering the need for cost-effective LBC techniques, we evaluated the efficacy of an inexpensive manual LBC (MLBC) technique against conventional cytological technique in terms of specimen adequacy and smear quality of oral smears. Materials and Methods: Cytological samples were collected from 21 patients using a cytobrush device. After preparation of a conventional smear, the brush containing the remaining sample was immersed in the preservative vial. The preserved material was processed by an MLBC technique and subsequently, direct smears were made from the prepared cell button. Both conventional and MLBC smears were stained by routine Papanicolaou technique and evaluated by an independent observer for the thickness of the smear, cellular distribution, resolution/clarity of cells, cellular staining characteristics and the presence of unsatisfactory background/artifacts. Each parameter was graded as satisfactory; or satisfactory, but limited; or unsatisfactory. Chi-square test was used to compare the values obtained (significance set at P ≤ 0.05). Results: MLBC technique produced a significant number of satisfactory smears with regard to cell distribution, clarity/resolution, staining characteristics and background/artifacts compared to conventional methods. Conclusions: MLBC is a cost-effective cytological technique that may produce oral smears with excellent cytomorphology and longer storage life. PMID:26980958

  11. New patient-controlled abdominal compression method in radiography: radiation dose and image quality.

    PubMed

    Piippo-Huotari, Oili; Norrman, Eva; Anderzén-Carlsson, Agneta; Geijer, Håkan

    2018-05-01

    The radiation dose for patients can be reduced with many methods and one way is to use abdominal compression. In this study, the radiation dose and image quality for a new patient-controlled compression device were compared with conventional compression and compression in the prone position . To compare radiation dose and image quality of patient-controlled compression compared with conventional and prone compression in general radiography. An experimental design with quantitative approach. After obtaining the approval of the ethics committee, a consecutive sample of 48 patients was examined with the standard clinical urography protocol. The radiation doses were measured as dose-area product and analyzed with a paired t-test. The image quality was evaluated by visual grading analysis. Four radiologists evaluated each image individually by scoring nine criteria modified from the European quality criteria for diagnostic radiographic images. There was no significant difference in radiation dose or image quality between conventional and patient-controlled compression. Prone position resulted in both higher dose and inferior image quality. Patient-controlled compression gave similar dose levels as conventional compression and lower than prone compression. Image quality was similar with both patient-controlled and conventional compression and was judged to be better than in the prone position.

  12. The Role of Conventional Ultrasound in the Assessment of Thyroid Nodule in Erbil City

    ERIC Educational Resources Information Center

    Musa, Sarbast Ismail; Hanary, Salah Mohammad

    2016-01-01

    Background: Nodular thyroid disease is relatively common although thyroid cancer is rare. The aim of this study is to evaluate the advantage and reliability of conventional ultrasound in correlating sonographic characteristics of thyroid nodule with US-FNAC guided result as a diagnostic aid in thyroid nodule. Method: 111 patients were examined by…

  13. A method of determining bending properties of poultry long bones using beam analysis and micro-CT data.

    PubMed

    Vaughan, Patrick E; Orth, Michael W; Haut, Roger C; Karcher, Darrin M

    2016-01-01

    While conventional mechanical testing has been regarded as a gold standard for the evaluation of bone heath in numerous studies, with recent advances in medical imaging, virtual methods of biomechanics are rapidly evolving in the human literature. The objective of the current study was to evaluate the feasibility of determining the elastic and failure properties of poultry long bones using established methods of analysis from the human literature. In order to incorporate a large range of bone sizes and densities, a small number of specimens were utilized from an ongoing study of Regmi et al. (2016) that involved humeri and tibiae from 3 groups of animals (10 from each) including aviary, enriched, and conventional housing systems. Half the animals from each group were used for 'training' that involved the development of a regression equation relating bone density and geometry to bending properties from conventional mechanical tests. The remaining specimens from each group were used for 'testing' in which the mechanical properties from conventional tests were compared to those predicted by the regression equations. Based on the regression equations, the coefficients of determination for the 'test' set of data were 0.798 for bending bone stiffness and 0.901 for the yield (or failure) moment of the bones. All regression slopes and intercepts values for the tests versus predicted plots were not significantly different from 1 and 0, respectively. The study showed the feasibility of developing future methods of virtual biomechanics for the evaluation of poultry long bones. With further development, virtual biomechanics may have utility in future in vivo studies to assess laying hen bone health over time without the need to sacrifice large groups of animals at each time point. © 2016 Poultry Science Association Inc.

  14. Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study

    PubMed Central

    MENDES, Bernardo de Azevedo Bahia; FERREIRA, Ricardo Alberto Neto; PITHON, Matheus Melo; HORTA, Martinho Campolina Rebello; OLIVEIRA, Dauro Douglas

    2014-01-01

    Objective The aim of this article was to assess how intraoral biodegradation influenced the surface characteristics and friction levels of metallic brackets used during 12 and 24 months of orthodontic treatment and also to compare the static friction generated in these brackets with four different methods of the ligation of orthodontic wires. Material and Methods Seventy premolar brackets as received from the manufacturer and 224 brackets that were used in previous orthodontic treatments were evaluated in this experiment. The surface morphology and the composition of the deposits found in the brackets were evaluated with rugosimetry, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Friction was analyzed by applying tensile tests simulating sliding mechanics with a 0.019x0.025" steel wire. The static friction levels produced by the following ligation methods were evaluated: loosely attached steel ligature around all four bracket wings, steel ligature attached to only two wings, conventional elastomeric ligation around all 4 bracket wings, and non-conventional Slide® elastomeric ligature. Results The results demonstrated the presence of biodegradation effects such as corrosion pits, plastic deformation, cracks, and material deposits. The main chemical elements found on these deposits were Carbon and Oxygen. The maximum friction produced by each ligation method changed according to the time of intraoral use. The steel ligature loosely attached to all four bracket wings produced the lowest friction levels in the new brackets. The conventional elastic ligatures generated the highest friction levels. The metallic brackets underwent significant degradation during orthodontic treatment, showing an increase in surface roughness and the deposit of chemical elements on the surface. Conclusion The levels of static friction decreased with use. The non-conventional elastic ligatures were the best alternative to reduce friction. PMID:25025560

  15. A review of MRI evaluation of demyelination in cuprizone murine model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krutenkova, E., E-mail: len--k@yandex.ru; Pan, E.; Khodanovich, M., E-mail: khodanovich@mail.tsu.ru

    The cuprizone mouse model of non-autoimmune demyelination reproduces some phenomena of multiple sclerosis and is appropriate for validation and specification of a new method of non-invasive diagnostics. In the review new data which are collected using the new MRI method are compared with one or more conventional MRI tools. Also the paper reviewed the validation of MRI approaches using histological or immunohistochemical methods. Luxol fast blue histological staining and myelin basic protein immunostaining is widespread. To improve the accuracy of non-invasive conventional MRI, multimodal scanning could be applied. The new quantitative MRI method of fast mapping of the macromolecular protonmore » fraction is a reliable biomarker of myelin in the brain and can be used for research of demyelination in animals. To date, a validation of MPF method on the CPZ mouse model of demyelination is not performed, although this method is probably the best way to evaluate demyelination using MRI.« less

  16. Leaching of indium from obsolete liquid crystal displays: Comparing grinding with electrical disintegration in context of LCA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dodbiba, Gjergj, E-mail: dodbiba@sys.t.u-tokyo.ac.jp; Nagai, Hiroki; Wang Lipang

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer Two pre-treatment methods, prior to leaching of indium from obsolete LCD modules, were described. Black-Right-Pointing-Pointer Conventional grinding and electrical disintegration have been evaluated and compared in the context of LCA. Black-Right-Pointing-Pointer Experimental data on the leaching capacity for indium and the electricity consumption of equipment were inputted into the LCA model in order to compare the environmental performance of each method. Black-Right-Pointing-Pointer An estimate for the environmental performance was calculated as the sum of six impact categories. Black-Right-Pointing-Pointer Electrical disintegration method outperforms conventional grinding in all impact categories. - Abstract: In order to develop an effective recycling systemmore » for obsolete Liquid Crystal Displays (LCDs), which would enable both the leaching of indium (In) and the recovery of a pure glass fraction for recycling, an effective liberation or size-reduction method would be an important pre-treatment step. Therefore, in this study, two different types of liberation methods: (1) conventional grinding, and (2) electrical disintegration have been tested and evaluated in the context of Life Cycle Assessment (LCA). In other words, the above-mentioned methods were compared in order to find out the one that ensures the highest leaching capacity for indium, as well as the lowest environmental burden. One of the main findings of this study was that the electrical disintegration was the most effective liberation method, since it fully liberated the indium containing-layer, ensuring a leaching capacity of 968.5 mg-In/kg-LCD. In turn, the estimate for the environmental burden was approximately five times smaller when compared with the conventional grinding.« less

  17. A new method and device of aligning patient setup lasers in radiation therapy.

    PubMed

    Hwang, Ui-Jung; Jo, Kwanghyun; Lim, Young Kyung; Kwak, Jung Won; Choi, Sang Hyuon; Jeong, Chiyoung; Kim, Mi Young; Jeong, Jong Hwi; Shin, Dongho; Lee, Se Byeong; Park, Jeong-Hoon; Park, Sung Yong; Kim, Siyong

    2016-01-08

    The aim of this study is to develop a new method to align the patient setup lasers in a radiation therapy treatment room and examine its validity and efficiency. The new laser alignment method is realized by a device composed of both a metallic base plate and a few acrylic transparent plates. Except one, every plate has either a crosshair line (CHL) or a single vertical line that is used for alignment. Two holders for radiochromic film insertion are prepared in the device to find a radiation isocenter. The right laser positions can be found optically by matching the shadows of all the CHLs in the gantry head and the device. The reproducibility, accuracy, and efficiency of laser alignment and the dependency on the position error of the light source were evaluated by comparing the means and the standard deviations of the measured laser positions. After the optical alignment of the lasers, the radiation isocenter was found by the gantry and collimator star shots, and then the lasers were translated parallel to the isocenter. In the laser position reproducibility test, the mean and standard deviation on the wall of treatment room were 32.3 ± 0.93 mm for the new method whereas they were 33.4 ± 1.49 mm for the conventional method. The mean alignment accuracy was 1.4 mm for the new method, and 2.1 mm for the conventional method on the walls. In the test of the dependency on the light source position error, the mean laser position was shifted just by a similar amount of the shift of the light source in the new method, but it was greatly magnified in the conventional method. In this study, a new laser alignment method was devised and evaluated successfully. The new method provided more accurate, more reproducible, and faster alignment of the lasers than the conventional method.

  18. Effects of conventional welding and laser welding on the tensile strength, ultimate tensile strength and surface characteristics of two cobalt-chromium alloys: a comparative study.

    PubMed

    Madhan Kumar, Seenivasan; Sethumadhava, Jayesh Raghavendra; Anand Kumar, Vaidyanathan; Manita, Grover

    2012-06-01

    The purpose of this study was to evaluate the efficacy of laser welding and conventional welding on the tensile strength and ultimate tensile strength of the cobalt-chromium alloy. Samples were prepared with two commercially available cobalt-chromium alloys (Wironium plus and Diadur alloy). The samples were sectioned and the broken fragments were joined using Conventional and Laser welding techniques. The welded joints were subjected to tensile and ultimate tensile strength testing; and scanning electron microscope to evaluate the surface characteristics at the welded site. Both on laser welding as well as on conventional welding technique, Diadur alloy samples showed lesser values when tested for tensile and ultimate tensile strength when compared to Wironium alloy samples. Under the scanning electron microscope, the laser welded joints show uniform welding and continuous molt pool all over the surface with less porosity than the conventionally welded joints. Laser welding is an advantageous method of connecting or repairing cast metal prosthetic frameworks.

  19. Public participation in environmental impact assessment-implementing the Aarhus Convention

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartley, Nicola; Wood, Christopher

    This article explores the nature of public participation in the environmental impact assessment (EIA) process in the context of the potential integration of the Aarhus Convention principles into the UK EIA system. Although the Convention advocates 'early' and 'effective' participation, these terms remain undefined and questions persist about exactly how to implement the Aarhus principles. Ten practice evaluation criteria derived from the Aarhus Convention are used to analyse the public participation procedures used in four UK waste disposal EIA case studies. The paper reports the extent to which the practice evaluation criteria were fulfilled, explores the types and effectiveness ofmore » the participation methods used in the EIAs, and highlights some of the key barriers that appear to impede the execution of 'early' and 'effective' participation programmes. It concludes that the Aarhus Convention will undoubtedly lead to a strengthening of participation procedures but that the level of improvement secured will depend upon how its ideals are interpreted and incorporated into legislation and practice.« less

  20. A Shot Number Based Approach to Performance Analysis in Table Tennis

    PubMed Central

    Yoshida, Kazuto; Yamada, Koshi

    2017-01-01

    Abstract The current study proposes a novel approach that improves the conventional performance analysis in table tennis by introducing the concept of frequency, or the number of shots, of each shot number. The improvements over the conventional method are as follows: better accuracy of the evaluation of skills and tactics of players, additional insights into scoring and returning skills and ease of understanding the results with a single criterion. The performance analysis of matches played at the 2012 Summer Olympics in London was conducted using the proposed method. The results showed some effects of the shot number and gender differences in table tennis. Furthermore, comparisons were made between Chinese players and players from other countries, what threw light on the skills and tactics of the Chinese players. The present findings demonstrate that the proposed method provides useful information and has some advantages over the conventional method. PMID:28210334

  1. Comparison of Para-Selles Bailenger/Kop-Color Fumouze, Para-Selles-Iodésine/Kop-Color II Fumouze diagnostic kits with conventional microscopic methods in identifying intestinal parasitic diseases in Senegal.

    PubMed

    Sow, Doudou; Dieng, Yémou; Haouchine, Djamal; Niang, Khadim; Niang, Thiane; Sylla, Khadime; Tine, Roger Clément; Ndiaye, Magatte; Ndiaye, Jean Louis; Faye, Babacar; Faye, Omar; Gaye, Oumar; Dieng, Thérèse; Izri, Arezki

    2017-09-01

    In the context of controlling intestinal parasites, accurate diagnosis is essential. Our objective was to evaluate the performance of new diagnostic kits compared to conventional microscopic methods in identifying intestinal parasites. Faeces collected in rural area in Senegal were subjected to several detection techniques. Thus, the sensitivity, specificity, positive and negative predictive values of new diagnostic techniques were compared to conventional merthiolate-iodine-formalin, conventional Bailenger and modified Ritchie. Furthermore, the kappa coefficient was calculated to evaluate the correlation between the new kit and those of modified Ritchie. Out of the 117 patients examined, 102 presented with a parasite, or prevalence of 87.1%. The Fumouze techniques proved to be as effective as the conventional methods in detecting flagellates and helminths with sensitivities ranging from 97 to 100%. However, conventional techniques were slightly more sensitive in identifying Endolimax nana and Blastocystis hominis . The correlation was nearly perfect (k = 0.83 and 1), respectively between Bailenger Fumouze, Iodesine Fumouze and modified Ritchie in identifying helminths while it was just acceptable (k = 0.27 and 0.28) in identifying B. hominis . The modified Ritchie technique routinely used in our laboratory remains a good diagnostic tool. However, the use of kit techniques was interesting when reading the pellet after concentration and the Colour KOP staining was a considerable contribution to the diagnosis of the vegetative forms. Therefore, it would be interesting to determine the cost of a stool test using Fumouze kit techniques to provide the most cost effective way.

  2. Comparative phenotypic and genotypic analysis of Edwardsiella spp. isolates from different hosts and geographic origins, with an emphasis on isolates formerly classified as E. tarda and an evaluation of diagnostic methods

    USDA-ARS?s Scientific Manuscript database

    Aims: Conventional phenotypic and genotypic analyses for the differentiation of phenotypically ambiguous Edwardsiella congeners was evaluated and historical E. tarda designations were linked to current taxonomic nomenclature. Methods and Results: Forty-seven Edwardsiella spp. isolates recovered over...

  3. [Role of BoBs technology in early missed abortion chorionic villi].

    PubMed

    Li, Z Y; Liu, X Y; Peng, P; Chen, N; Ou, J; Hao, N; Zhou, J; Bian, X M

    2018-05-25

    Objective: To investigate the value of bacterial artificial chromosome-on-beads (BoBs) technology in the genetic analysis of early missed abortion chorionic villi. Methods: Early missed abortion chorionic villi were detected with both conventional karyotyping method and BoBs technology in Peking Union Medical Hospital from July 2014 to March 2015. Compared the results of BoBs with conventional karyotyping analysis to evaluate the sensitivity, specificity and accuracy of this new method. Results: (1) A total of 161 samples were tested successfully in the technology of BoBs, 131 samples were tested successfully in the method of conventional karyotyping. (2) All of the cases obtained from BoBs results in (2.7±0.6) days and obtained from conventional karyotyping results in (22.5±1.9) days. There was significant statistical difference between the two groups ( t= 123.315, P< 0.01) . (3) Out of 161 cases tested in BoBs, 85 (52.8%, 85/161) cases had the abnormal chromosomes, including 79 cases chromosome number abnormality, 4 cases were chromosome segment deletion, 2 cases mosaic. Out of 131 cases tested successfully in conventional karyotyping, 79 (60.3%, 79/131) cases had the abnormal chromosomes including 62 cases chromosome number abnormality, 17 cases other chromosome number abnormality, and the rate of chromosome abnormality between two methods was no significant differences ( P =0.198) . (4) Conventional karyotyping results were served as the gold standard, the accuracy of BoBs for abnormal chromosomes was 82.4% (108/131) , analysed the normal chromosomes (52 cases) and chromosome number abnormality (62 cases) tested in conventional karyotyping, the accuracy of BoBs for chromosome number abnormality was 94.7% (108/114) . Conclusion: BoBs is a rapid reliable and easily operated method to test early missed abortion chorionic villi chromosomal abnormalities.

  4. The possibility of application of spiral brain computed tomography to traumatic brain injury.

    PubMed

    Lim, Daesung; Lee, Soo Hoon; Kim, Dong Hoon; Choi, Dae Seub; Hong, Hoon Pyo; Kang, Changwoo; Jeong, Jin Hee; Kim, Seong Chun; Kang, Tae-Sin

    2014-09-01

    The spiral computed tomography (CT) with the advantage of low radiation dose, shorter test time required, and its multidimensional reconstruction is accepted as an essential diagnostic method for evaluating the degree of injury in severe trauma patients and establishment of therapeutic plans. However, conventional sequential CT is preferred for the evaluation of traumatic brain injury (TBI) over spiral CT due to image noise and artifact. We aimed to compare the diagnostic power of spiral facial CT for TBI to that of conventional sequential brain CT. We evaluated retrospectively the images of 315 traumatized patients who underwent both brain CT and facial CT simultaneously. The hemorrhagic traumatic brain injuries such as epidural hemorrhage, subdural hemorrhage, subarachnoid hemorrhage, and contusional hemorrhage were evaluated in both images. Statistics were performed using Cohen's κ to compare the agreement between 2 imaging modalities and sensitivity, specificity, positive predictive value, and negative predictive value of spiral facial CT to conventional sequential brain CT. Almost perfect agreement was noted regarding hemorrhagic traumatic brain injuries between spiral facial CT and conventional sequential brain CT (Cohen's κ coefficient, 0.912). To conventional sequential brain CT, sensitivity, specificity, positive predictive value, and negative predictive value of spiral facial CT were 92.2%, 98.1%, 95.9%, and 96.3%, respectively. In TBI, the diagnostic power of spiral facial CT was equal to that of conventional sequential brain CT. Therefore, expanded spiral facial CT covering whole frontal lobe can be applied to evaluate TBI in the future. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Teaching Dental Students to Understand the Temporomandibular Joint Using MRI: Comparison of Conventional and Digital Learning Methods.

    PubMed

    Arús, Nádia A; da Silva, Átila M; Duarte, Rogério; da Silveira, Priscila F; Vizzotto, Mariana B; da Silveira, Heraldo L D; da Silveira, Heloisa E D

    2017-06-01

    The aims of this study were to evaluate and compare the performance of dental students in interpreting the temporomandibular joint (TMJ) with magnetic resonance imaging (MRI) scans using two learning methods (conventional and digital interactive learning) and to examine the usability of the digital learning object (DLO). The DLO consisted of tutorials about MRI and anatomic and functional aspects of the TMJ. In 2014, dental students in their final year of study who were enrolled in the elective "MRI Interpretation of the TMJ" course comprised the study sample. After exclusions for nonattendance and other reasons, 29 of the initial 37 students participated in the study, for a participation rate of 78%. The participants were divided into two groups: a digital interactive learning group (n=14) and a conventional learning group (n=15). Both methods were assessed by an objective test applied before and after training and classes. Aspects such as support and training requirements, complexity, and consistency of the DLO were also evaluated using the System Usability Scale (SUS). A significant between-group difference in the posttest results was found, with the conventional learning group scoring better than the DLO group, indicated by mean scores of 9.20 and 8.11, respectively, out of 10. However, when the pretest and posttest results were compared, both groups showed significantly improved performance. The SUS score was 89, which represented a high acceptance of the DLO by the users. The students who used the conventional method of learning showed superior performance in interpreting the TMJ using MRI compared to the group that used digital interactive learning.

  6. Evaluation of two matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) systems for the identification of Candida species.

    PubMed

    Lacroix, C; Gicquel, A; Sendid, B; Meyer, J; Accoceberry, I; François, N; Morio, F; Desoubeaux, G; Chandenier, J; Kauffmann-Lacroix, C; Hennequin, C; Guitard, J; Nassif, X; Bougnoux, M-E

    2014-02-01

    Candida spp. are responsible for severe infections in immunocompromised patients and those undergoing invasive procedures. The accurate identification of Candida species is important because emerging species can be associated with various antifungal susceptibility spectra. Conventional methods have been developed to identify the most common pathogens, but have often failed to identify uncommon species. Several studies have reported the efficiency of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) for the identification of clinically relevant Candida species. In this study, we evaluated two commercially available MALDI-TOF systems, Andromas™ and Bruker Biotyper™, for Candida identification in routine diagnosis. For this purpose, we investigated 1383 Candida isolates prospectively collected in eight hospital laboratories during routine practice. MALDI-TOF MS results were compared with those obtained using conventional phenotypic methods. Analysis of rDNA gene sequences with internal transcribed regions or D1-D2 regions is considered the reference standard for identification. Both MALDI-TOF MS systems could accurately identify 98.3% of the isolates at the species level (1359/1383 for Andromas™; 1360/1383 for Bruker Biotyper™) vs. 96.5% for conventional techniques. Furthermore, whereas conventional methods failed to identify rare or emerging species, these were correctly identified by MALDI-TOF MS. Both MALDI-TOF MS systems are accurate and cost-effective alternatives to conventional methods for mycological identification of clinically relevant Candida species and should improve the diagnosis of fungal infections as well as patient management. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.

  7. SU-G-IeP2-06: Evaluation of Registration Accuracy for Cone-Beam CT Reconstruction Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, J; Wang, P; Zhang, H

    2016-06-15

    Purpose: Cone-beam (CB) computed tomography (CT) is used for image guidance during radiotherapy treatment delivery. Conventional Feldkamp and compressed sensing (CS) based CBCT recon-struction techniques are compared for image registration. This study is to evaluate the image registration accuracy of conventional and CS CBCT for head-and-neck (HN) patients. Methods: Ten HN patients with oropharyngeal tumors were retrospectively selected. Each HN patient had one planning CT (CTP) and three CBCTs were acquired during an adaptive radiotherapy proto-col. Each CBCT was reconstructed by both the conventional (CBCTCON) and compressed sens-ing (CBCTCS) methods. Two oncologists manually labeled 23 landmarks of normal tissue andmore » implanted gold markers on both the CTP and CBCTCON. Subsequently, landmarks on CTp were propagated to CBCTs, using a b-spline-based deformable image registration (DIR) and rigid registration (RR). The errors of these registration methods between two CBCT methods were calcu-lated. Results: For DIR, the mean distance between the propagated and the labeled landmarks was 2.8 mm ± 0.52 for CBCTCS, and 3.5 mm ± 0.75 for CBCTCON. For RR, the mean distance between the propagated and the labeled landmarks was 6.8 mm ± 0.92 for CBCTCS, and 8.7 mm ± 0.95 CBCTCON. Conclusion: This study has demonstrated that CS CBCT is more accurate than conventional CBCT in image registration by both rigid and non-rigid methods. It is potentially suggested that CS CBCT is an improved image modality for image guided adaptive applications.« less

  8. Evaluation of physicochemical properties of root-end filling materials using conventional and Micro-CT tests

    PubMed Central

    TORRES, Fernanda Ferrari Esteves; BOSSO-MARTELO, Roberta; ESPIR, Camila Galletti; CIRELLI, Joni Augusto; GUERREIRO-TANOMARU, Juliane Maria; TANOMARU-FILHO, Mario

    2017-01-01

    Abstract Objective To evaluate solubility, dimensional stability, filling ability and volumetric change of root-end filling materials using conventional tests and new Micro-CT-based methods. Material and Methods 7 Results The results suggested correlated or complementary data between the proposed tests. At 7 days, BIO showed higher solubility and at 30 days, showed higher volumetric change in comparison with MTA (p<0.05). With regard to volumetric change, the tested materials were similar (p>0.05) at 7 days. At 30 days, they presented similar solubility. BIO and MTA showed higher dimensional stability than ZOE (p<0.05). ZOE and BIO showed higher filling ability (p<0.05). Conclusions ZOE presented a higher dimensional change, and BIO had greater solubility after 7 days. BIO presented filling ability and dimensional stability, but greater volumetric change than MTA after 30 days. Micro-CT can provide important data on the physicochemical properties of materials complementing conventional tests. PMID:28877275

  9. Single-incision Laparoscopic Surgery (SILS) in general surgery: a review of current practice.

    PubMed

    Froghi, Farid; Sodergren, Mikael Hans; Darzi, Ara; Paraskeva, Paraskevas

    2010-08-01

    Single-incision laparoscopic surgery (SILS) aims to eliminate multiple port incisions. Although general operative principles of SILS are similar to conventional laparoscopic surgery, operative techniques are not standardized. This review aims to evaluate the current use of SILS published in the literature by examining the types of operations performed, techniques employed, and relevant complications and morbidity. This review considered a total of 94 studies reporting 1889 patients evaluating 17 different general surgical operations. There were 8 different access techniques reported using conventional laparoscopic instruments and specifically designed SILS ports. There is extensive heterogeneity associated with operating methods and in particular ways of overcoming problems with retraction and instrumentation. Published complications, morbidity, and hospital length of stay are comparable to conventional laparoscopy. Although SILS provides excellent cosmetic results and morbidity seems similar to conventional laparoscopy, larger randomized controlled trials are needed to assess the safety and efficacy of this novel technique.

  10. A new concept and a comprehensive evaluation of SYSMEX UF-1000i  flow cytometer to identify culture-negative urine specimens in patients with UTI.

    PubMed

    Monsen, T; Ryden, P

    2017-09-01

    Urinary tract infections (UTIs) are among the most common bacterial infections in men and urine culture is gold standard for diagnosis. Considering the high prevalence of culture-negative specimens, any method that identifies such specimens is of interest. The aim was to evaluate a new screening concept for flow cytometry analysis (FCA). The outcomes were evaluated against urine culture, uropathogen species and three conventional screening methods. A prospective, consecutive study examined 1,312 urine specimens, collected during January and February 2012. The specimens were analyzed using the Sysmex UF1000i FCA. Based on the FCA data culture negative specimens were identified in a new model by use of linear discriminant analysis (FCA-LDA). In total 1,312 patients were included. In- and outpatients represented 19.6% and 79.4%, respectively; 68.3% of the specimens originated from women. Of the 610 culture-positive specimens, Escherichia coli represented 64%, enterococci 8% and Klebsiella spp. 7%. Screening with FCA-LDA at 95% sensitivity identified 42% (552/1312) as culture negative specimens when UTI was defined according to European guidelines. The proposed screening method was either superior or similar in comparison to the three conventional screening methods. In conclusion, the proposed/suggested and new FCA-LDA screening method was superior or similar to three conventional screening methods. We recommend the proposed screening method to be used in clinic to exclude culture negative specimens, to reduce workload, costs and the turnaround time. In addition, the FCA data may add information that enhance handling and support diagnosis of patients with suspected UTI pending urine culture [corrected].

  11. Cervical motion assessment using virtual reality.

    PubMed

    Sarig-Bahat, Hilla; Weiss, Patrice L; Laufer, Yocheved

    2009-05-01

    Repeated measures of cervical motion in asymptomatic subjects. To introduce a virtual reality (VR)-based assessment of cervical range of motion (ROM); to establish inter and intratester reliability of the VR-based assessment in comparison with conventional assessment in asymptomatic individuals; and to evaluate the effect of a single VR session on cervical ROM. Cervical ROM and clinical issues related to neck pain is frequently studied. A wide variety of methods is available for evaluation of cervical motion. To date, most methods rely on voluntary responses to an assessor's instructions. However, in day-to-day life, head movement is generally an involuntary response to multiple stimuli. Therefore, there is a need for a more functional assessment method, using sensory stimuli to elicit spontaneous neck motion. VR attributes may provide a methodology for achieving this goal. A novel method was developed for cervical motion assessment utilizing an electromagnetic tracking system and a VR game scenario displayed via a head mounted device. Thirty asymptomatic participants were assessed by both conventional and VR-based methods. Inter and intratester repeatability analyses were performed. The effect of a single VR session on ROM was evaluated. Both assessments showed non-biased results between tests and between testers (P > 0.1). Full-cycle repeatability coefficients ranged between 15.0 degrees and 29.2 degrees with smaller values for rotation and for the VR assessment. A single VR session significantly increased ROM, with largest effect found in the rotation direction. Inter and intratester reliability was supported for both the VR-based and the conventional methods. Results suggest better repeatability for the VR method, with rotation being more precise than flexion/extension. A single VR session was found to be effective in increasing cervical motion, possibly due to its motivating effect.

  12. Conserving biodiversity and ecosystem function through limited development: an empirical evaluation.

    PubMed

    Milder, Jeffrey C; Lassoie, James P; Bedford, Barbara L

    2008-02-01

    Suburban, exurban, and rural development in the United States consumes nearly 1 million hectares of land per year and is a leading threat to biodiversity. In response to this threat, conservation development has been advanced as a way to combine land development and land conservation while providing functional protection for natural resources. Yet, although conservation development techniques have been in use for decades, there have been few critical evaluations of their conservation effectiveness. We addressed this deficiency by assessing the conservation outcomes of one type of conservation development project: conservation and limited development projects (CLDPs). Conducted by land trusts, landowners, and developers, CLDPs use revenue from limited development to finance the protection of land and natural resources. We compared a sample of 10 CLDPs from the eastern United States with their respective baseline scenarios (conventional development) and with a sample of conservation subdivisions--a different conservation development technique characterized by higher-density development. To measure conservation success, we created an evaluation method containing eight indicators that quantify project impacts to terrestrial and aquatic ecosystems at the site and in the surrounding landscape. The CLDPs protected and managed threatened natural resources including rare species and ecological communities. In terms of conservation benefits, the CLDPs significantly outperformed their respective baseline scenarios and the conservation subdivisions. These results imply that CLDPs can offer a low-impact alternative to conventional development and a low-cost method for protecting land when conventional conservation techniques are too expensive. In addition, our evaluation method demonstrates how planners and developers can incorporate appropriate ecological considerations when designing, reviewing, and evaluating conservation development projects.

  13. New method: calculation of magnification factor from an intracardiac marker.

    PubMed

    Cha, S D; Incarvito, J; Maranhao, V

    1983-01-01

    In order to calculate a magnification factor (MF), an intracardiac marker (pigtail catheter with markers) was evaluated using a new formula and correlated with the conventional grid method. By applying the Pythagorean theorem and trigonometry, a new formula was developed, which is (formula; see text) In an experimental study, MF by the intracardiac markers was 0.71 +/- 0.15 (M +/- SD) and one by the grid method was 0.72 +/- 0.15, with a correlation coefficient of 0.96. In patients study, MF by the intracardiac markers was 0.77 +/- 0.06 and one by the grid method was 0.77 +/- 0.05. We conclude that this new method is simple and the results were comparable to the conventional grid method at mid-chest level.

  14. Validation of rapid descriptive sensory methods against conventional descriptive analyses: A systematic review.

    PubMed

    Aguiar, Lorena Andrade de; Melo, Lauro; de Lacerda de Oliveira, Lívia

    2018-04-03

    A major drawback of conventional descriptive profile (CDP) in sensory evaluation is the long time spent in panel training. Rapid descriptive methods (RDM) have increased significantly. Some of them have been compared with CDP for validation. In Health Sciences, systematic reviews (SR) are performed to evaluate validation of diagnostic tests in relation to a gold standard method. SR present a well-defined protocol to summarize research evidence and to evaluate the quality of the studies with determined criteria. We adapted SR protocol to evaluate the validation of RDM against CDP as satisfactory procedures to obtain food characterization. We used "Population Intervention Comparison Outcome Study - PICOS" framework to design the research in which "Population" was food/ beverages; "intervention" were RDM, "Comparison" was CDP as gold standard, "Outcome" was the ability of RDM to generate similar descriptive profiles in comparison with CDP and "Studies" was sensory descriptive analyses. The proportion of studies concluding for similarity of the RDM with CDP ranged from 0% to 100%. Low and moderate risk of bias were reached by 87% and 13% of the studies, respectively, supporting the conclusions of SR. RDM with semi-trained assessors and evaluation of individual attributes presented higher percentages of concordance with CDP.

  15. Microsurgical Versus Conventional Skin Closure in the Laboratory Rat (Rattus norvegicus)

    DTIC Science & Technology

    microscope using 6/0 monocryl. Wound strength was measured using a published method. A harvested incision was suspended with forceps and water was slowly...evaluated histologically using published methods to examine vascularization, fibroblast proliferation, inflammation and epithelialization. Results

  16. Software-assisted post-interventional assessment of radiofrequency ablation

    NASA Astrophysics Data System (ADS)

    Rieder, Christian; Geisler, Benjamin; Bruners, Philipp; Isfort, Peter; Na, Hong-Sik; Mahnken, Andreas H.; Hahn, Horst K.

    2014-03-01

    Radiofrequency ablation (RFA) is becoming a standard procedure for minimally invasive tumor treatment in clinical practice. Due to its common technical procedure, low complication rate, and low cost, RFA has become an alternative to surgical resection in the liver. To evaluate the therapy success of RFA, thorough follow-up imaging is essential. Conventionally, shape, size, and position of tumor and coagulation are visually compared in a side-by-side manner using pre- and post-interventional images. To objectify the verification of the treatment success, a novel software assistant allowing for fast and accurate comparison of tumor and coagulation is proposed. In this work, the clinical value of the proposed assessment software is evaluated. In a retrospective clinical study, 39 cases of hepatic tumor ablation are evaluated using the prototype software and conventional image comparison by four radiologists with different levels of experience. The cases are randomized and evaluated in two sessions to avoid any recall-bias. Self-confidence of correct diagnosis (local recurrence vs. no local recurrence) on a six-point scale is given for each case by the radiologists. Sensitivity, specificity, positive and negative predictive values as well as receiver operating curves are calculated for both methods. It is shown that the software-assisted method allows physicians to correctly identify local tumor recurrence with a higher percentage than the conventional method (sensitivity: 0.6 vs. 0.35), whereas the percentage of correctly identified successful ablations is slightly reduced (specificity: 0.83 vs. 0.89).

  17. Comparison of total oxidant/antioxidant status in unconjugated hyperbilirubinemia of newborn before and after conventional and LED phototherapy: A prospective randomized controlled trial.

    PubMed

    Demirel, Gamze; Uras, Nurdan; Celik, Istemi H; Aksoy, Hatice T; Oguz, Serife S; Erdeve, Omer; Erel, Ozcan; Dilmen, Ugur

    2010-10-01

    We evaluated and compared the oxidant and antioxidant status of hyperbilirubinemic infants before and after the two forms of phototherapy: conventional and LED phototherapy, in order to identify the optimal treatment method. Thirty newborns exposed to conventional (Group I) phototherapy and 30 infants exposed to LED phototherapy (Group II) were studied. The serum total antioxidant capacity (TAC) and the total oxidant status (TOS) were assessed by EREL's method. There were no statistically significant differences in TAC or TOS levels between Group I and Group II prior to phototherapy, and no statistically significant difference in TAC levels between the two groups after phototherapy; however, TOS levels were significantly lower in Group II compared to Group I after phototherapy. Oxidative stress index (OSI) increased after conventional phototherapy (p < 0.05) The increase in TOS following conventional phototherapy was not not observed following LED phototherapy. This difference should be considered when using phototherapy.

  18. Cervical cancer patterns with automation-assisted and conventional cytological screening: a randomized study.

    PubMed

    Anttila, Ahti; Pokhrel, Arun; Kotaniemi-Talonen, Laura; Hakama, Matti; Malila, Nea; Nieminen, Pekka

    2011-03-01

    The purpose was to evaluate alternative cytological screening methods in population-based screening for cervical cancer up to cancer incidence and mortality outcome. Automation-assisted screening was compared to conventional cytological screening in a randomized design. The study was based on follow-up of 503,391 women invited in the Finnish cervical cancer screening program during 1999-2003. The endpoints were incident cervical cancer, severe intraepithelial neoplasia and deaths from cervical cancer. One third of the women had been randomly allocated to automation-assisted screening and two thirds to conventional cytology. Information on cervical cancer and severe neoplasia were obtained through 1999-2007 from a linkage between screening and cancer registry files. There were altogether 3.2 million woman-years at risk, and the average follow-up time was 6.3 years. There was no difference in the risk of cervical cancer between the automation-assisted and conventional screening methods; the relative risk (RR) of cervical cancer between the study and control arm was 1.00 (95% confidence interval [CI] = 0.76-1.29) among all invited and 1.08 (95% CI = 0.76-1.51) among women who were test negative at entry. Comparing women who were test negative with nonscreened, RR of cervical cancer incidence was 0.26, 95% CI = 0.19-0.36 and of mortality 0.24 (0.13-0.43). Both methods were valid for screening. Because cervical cancer is rare in our country, we cannot rule out small differences between methods. Evidence on alternative methods for cervical cancer screening is increasing and it is thus feasible to evaluate new methods in large-scale population-based screening programs up to cancer outcome. Copyright © 2010 UICC.

  19. Effect of corn residue harvest method with ruminally undegradable protein supplementation on performance of growing calves and fiber digestibility.

    PubMed

    King, T M; Bondurant, R G; Jolly-Breithaupt, M L; Gramkow, J L; Klopfenstein, T J; MacDonald, J C

    2017-12-01

    Two experiments evaluated the effects of corn residue harvest method on animal performance and diet digestibility. Experiment 1 was designed as a 2 × 2 + 1 factorial arrangement of treatments using 60 individually fed crossbred steers (280 kg [SD 32] initial BW; = 12). Factors were the corn residue harvest method (high-stem and conventional) and supplemental RUP at 2 concentrations (0 and 3.3% diet DM). A third harvest method (low-stem) was also evaluated, but only in diets containing supplemental RUP at 3.3% diet DM because of limitations in the amount of available low-stem residue. Therefore, the 3 harvest methods were compared only in diets containing supplemental RUP. In Exp. 2, 9 crossbred wethers were blocked by BW (42.4 kg [SD 7] initial BW) and randomly assigned to diets containing corn residue harvested 1 of 3 ways (low-stem, high-stem, and conventional). In Exp. 1, steers fed the low-stem residue diet had greater ADG compared with the steers fed conventionally harvested corn residue ( = 0.03; 0.78 vs. 0.63 kg), whereas steers fed high-stem residue were intermediate ( > 0.17; 0.69 kg), not differing from either conventional or low-stem residues. Results from in vitro OM digestibility suggest that low-stem residue had the greatest ( < 0.01) amount of digestible OM compared with the other 2 residue harvest methods, which did not differ ( = 0.32; 55.0, 47.8, and 47.1% for low-stem, high-stem, and conventional residues, respectively). There were no differences in RUP content (40% of CP) and RUP digestibility (60%) among the 3 residues ( ≥ 0.35). No interactions were observed between harvest method and the addition of RUP ( ≥ 0.12). The addition of RUP tended to result in improved ADG (0.66 ± 0.07 vs. 0.58 ± 0.07 for supplemental RUP and no RUP, respectively; = 0.08) and G:F (0.116 ± 0.006 vs. 0.095 ± 0.020 for supplemental RUP and no RUP, respectively; = 0.02) compared with similar diets without the additional RUP. In Exp. 2, low-stem residue had greater DM and OM digestibility and DE ( < 0.01) than high-stem and conventional residues, which did not differ ( ≥ 0.63). Low-stem residue also had the greatest NDF digestibility (NDFD; < 0.01), whereas high-stem residue had greater NDFD than conventional residue ( < 0.01). Digestible energy was greatest for low-stem residue ( < 0.05) and did not differ between high-stem and conventional residues ( = 0.50). Reducing the proportion of stem in the bale through changes in the harvest method increased the nutritive quality of corn residue.

  20. Ergonomic evaluation of conventional and improved methods of aonla pricking with women workers.

    PubMed

    Rai, Arpana; Gandhi, Sudesh; Sharma, D K

    2012-01-01

    Conventional and improved methods of aonla pricking were evaluated ergonomically on an experiment conducted for 20 minute with women workers. The working heart rate, energy expenditure rate, total cardiac cost of work and physiological cost of work with conventional tools varied from 93-102 beats.min-1, 6-7.5 kJ.min-1, 285-470 beats, 14 -23 beats.min-1 while with machine varied from 96-105 beats.min-1, 6.5-8 kJ.min-1 , 336-540 beats, 16-27 beats.min-1 respectively. OWAS score for conventional method was 2 indicating corrective measures in near future while with machine was 1 indicating no corrective measures. Result of Nordic Musculoskeletal Questionnaire revealed that subjects complaint of pain in back, neck, right shoulder and right hand due to unnatural body posture and repetitive movement with hand tool. Moreover pricking was carried out in improper lighting conditions (200-300 lux) resulting into finger injuries from sharp edges of hand tool, whereas with machine no such problems were observed. Output with machine increased thrice than hand pricking in a given time. Machine was found useful in terms of saving time, increased productivity, enhanced safety and comfort as involved improved posture, was easy to handle and operate, thus increasing efficiency of the worker leading to better quality of life.

  1. "Evaluation as Illumination: A New Approach to the Study of Innovatory Programs". Occasional Paper.

    ERIC Educational Resources Information Center

    Parlett, Malcolm; Hamilton, David

    Conventional approaches to program evaluation have followed the experimental and psychometric traditions dominant in educational research. Their aim (unfulfilled) of achieving fully objective methods had led to studies that are artificial and restricted in scope. Illuminative evaluation is introduced as a total re-appraisal of the rationale and…

  2. Selection of biological indicator for validating microwave heating sterilization.

    PubMed

    Sasaki, K; Mori, Y; Honda, W; Miyake, Y

    1998-01-01

    For the purpose of selecting an appropriate biological indicator for evaluation of the effects of microwave heating sterilization, we examined aerobic bacterial spores to determine whether microwaves have non-thermal sterilization effects. After microwave irradiation on dry bacterial spores (three species), none of the bacterial spores were killed. The survival rate of the spores after microwave irradiation of spore suspensions (twelve species) was compared with that after heating by a conventional method. The order of heat resistance in the bacterial species was similar between the two heating methods. Bacillus stearothermophilus spores were the most heat-resistant. These results suggest that microwaves have no non-thermal sterilization effects on bacterial spores, the specific resistant spores to microwave heating, and microwave heating sterilization can be evaluated in the same way as for conventional heating sterilization. As a biological indicator for evaluation of overkill sterilization, B. stearothermophilus spores may be appropriate for microwave heating sterilization as well as steam sterilization.

  3. Sensor assembly method using silicon interposer with trenches for three-dimensional binocular range sensors

    NASA Astrophysics Data System (ADS)

    Nakajima, Kazuhiro; Yamamoto, Yuji; Arima, Yutaka

    2018-04-01

    To easily assemble a three-dimensional binocular range sensor, we devised an alignment method for two image sensors using a silicon interposer with trenches. The trenches were formed using deep reactive ion etching (RIE) equipment. We produced a three-dimensional (3D) range sensor using the method and experimentally confirmed that sufficient alignment accuracy was realized. It was confirmed that the alignment accuracy of the two image sensors when using the proposed method is more than twice that of the alignment assembly method on a conventional board. In addition, as a result of evaluating the deterioration of the detection performance caused by the alignment accuracy, it was confirmed that the vertical deviation between the corresponding pixels in the two image sensors is substantially proportional to the decrease in detection performance. Therefore, we confirmed that the proposed method can realize more than twice the detection performance of the conventional method. Through these evaluations, the effectiveness of the 3D binocular range sensor aligned by the silicon interposer with the trenches was confirmed.

  4. Quantitative evaluation of the disintegration of orally rapid disintegrating tablets by X-ray computed tomography.

    PubMed

    Otsuka, Makoto; Yamanaka, Azusa; Uchino, Tomohiro; Otsuka, Kuniko; Sadamoto, Kiyomi; Ohshima, Hiroyuki

    2012-01-01

    To measure the rapid disintegration of Oral Disintegrating Tablets (ODT), a new test (XCT) was developed using X-ray computing tomography (X-ray CT). Placebo ODT, rapid disintegration candy (RDC) and Gaster®-D-Tablets (GAS) were used as model samples. All these ODTs were used to measure oral disintegration time (DT) in distilled water at 37±2°C by XCT. DTs were affected by the width of mesh screens, and degree to which the tablet holder vibrated from air bubbles. An in-vivo tablet disintegration test was performed for RDC using 11 volunteers. DT by the in-vivo method was significantly longer than that using the conventional tester. The experimental conditions for XCT such as the width of the mesh screen and degree of vibration were adjusted to be consistent with human DT values. Since DTs by the XCT method were almost the same as the human data, this method was able to quantitatively evaluate the rapid disintegration of ODT under the same conditions as inside the oral cavity. The DTs of four commercially available ODTs were comparatively evaluated by the XCT method, conventional tablet disintegration test and in-vivo method.

  5. Intraoperative panoramic image using alignment grid, is it accurate?

    PubMed

    Apivatthakakul, T; Duanghakrung, M; Luevitoonvechkit, S; Patumasutra, S

    2013-07-01

    Minimally invasive orthopedic trauma surgery relies heavily on intraoperative fluoroscopic images to evaluate the quality of fracture reduction and fixation. However, fluoroscopic images have a narrow field of view and often cannot visualize the entire long bone axis. To compare the coronal femoral alignment between conventional X-rays to that achieved with a new method of acquiring a panoramic intraoperative image. Twenty-four cadaveric femurs with simple diaphyseal fractures were fixed with an angulated broad DCP to create coronal plane malalignment. An intraoperative alignment grid was used to help stitch different fluoroscopic images together to produce a panoramic image. A conventional X-ray of the entire femur was then performed. The coronal plane angulation in the panoramic images was then compared to the conventional X-rays using a Wilcoxon signed rank test. The mean angle measured from the panoramic view was 173.9° (range 169.3°-178.0°) with median of 173.2°. The mean angle measured from the conventional X-ray was 173.4° (range 167.7°-178.7°) with a median angle of 173.5°. There was no significant difference between both methods of measurement (P = 0.48). Panoramic images produced by stitching fluoroscopic images together with help of an alignment grid demonstrated the same accuracy at evaluating the coronal plane alignment of femur fractures as conventional X-rays.

  6. Evaluation of airborne lidar data to predict vegetation Presence/Absence

    USGS Publications Warehouse

    Palaseanu-Lovejoy, M.; Nayegandhi, A.; Brock, J.; Woodman, R.; Wright, C.W.

    2009-01-01

    This study evaluates the capabilities of the Experimental Advanced Airborne Research Lidar (EAARL) in delineating vegetation assemblages in Jean Lafitte National Park, Louisiana. Five-meter-resolution grids of bare earth, canopy height, canopy-reflection ratio, and height of median energy were derived from EAARL data acquired in September 2006. Ground-truth data were collected along transects to assess species composition, canopy cover, and ground cover. To decide which model is more accurate, comparisons of general linear models and generalized additive models were conducted using conventional evaluation methods (i.e., sensitivity, specificity, Kappa statistics, and area under the curve) and two new indexes, net reclassification improvement and integrated discrimination improvement. Generalized additive models were superior to general linear models in modeling presence/absence in training vegetation categories, but no statistically significant differences between the two models were achieved in determining the classification accuracy at validation locations using conventional evaluation methods, although statistically significant improvements in net reclassifications were observed. ?? 2009 Coastal Education and Research Foundation.

  7. Quantitative evaluation of DNA damage and mutation rate by atmospheric and room-temperature plasma (ARTP) and conventional mutagenesis.

    PubMed

    Zhang, Xue; Zhang, Chong; Zhou, Qian-Qian; Zhang, Xiao-Fei; Wang, Li-Yan; Chang, Hai-Bo; Li, He-Ping; Oda, Yoshimitsu; Xing, Xin-Hui

    2015-07-01

    DNA damage is the dominant source of mutation, which is the driving force of evolution. Therefore, it is important to quantitatively analyze the DNA damage caused by different mutagenesis methods, the subsequent mutation rates, and their relationship. Atmospheric and room temperature plasma (ARTP) mutagenesis has been used for the mutation breeding of more than 40 microorganisms. However, ARTP mutagenesis has not been quantitatively compared with conventional mutation methods. In this study, the umu test using a flow-cytometric analysis was developed to quantify the DNA damage in individual viable cells using Salmonella typhimurium NM2009 as the model strain and to determine the mutation rate. The newly developed method was used to evaluate four different mutagenesis systems: a new ARTP tool, ultraviolet radiation, 4-nitroquinoline-1-oxide (4-NQO), and N-methyl-N'-nitro-N-nitrosoguanidine (MNNG) mutagenesis. The mutation rate was proportional to the corresponding SOS response induced by DNA damage. ARTP caused greater DNA damage to individual living cells than the other conventional mutagenesis methods, and the mutation rate was also higher. By quantitatively comparing the DNA damage and consequent mutation rate after different types of mutagenesis, we have shown that ARTP is a potentially powerful mutagenesis tool with which to improve the characteristics of microbial cell factories.

  8. A Cubic Radial Basis Function in the MLPG Method for Beam Problems

    NASA Technical Reports Server (NTRS)

    Raju, I. S.; Phillips, D. R.

    2002-01-01

    A non-compactly supported cubic radial basis function implementation of the MLPG method for beam problems is presented. The evaluation of the derivatives of the shape functions obtained from the radial basis function interpolation is much simpler than the evaluation of the moving least squares shape function derivatives. The radial basis MLPG yields results as accurate or better than those obtained by the conventional MLPG method for problems with discontinuous and other complex loading conditions.

  9. Revisiting the susceptibility testing of Mycobacterium tuberculosis to ethionamide in solid culture medium.

    PubMed

    Lakshmi, Rajagopalan; Ramachandran, Ranjani; Kumar, D Ravi; Sundar, A Syam; Radhika, G; Rahman, Fathima; Selvakumar, N; Kumar, Vanaja

    2015-11-01

    Increase in the isolation of drug resistant phenotypes of Mycobacterium tuberculosis necessitates accuracy in the testing methodology. Critical concentration defining resistance for ethionamide (ETO), needs re-evaluation in accordance with the current scenario. Thus, re-evaluation of conventional minimum inhibitory concentration (MIC) and proportion sensitivity testing (PST) methods for ETO was done to identify the ideal breakpoint concentration defining resistance. Isolates of M. tuberculosis (n=235) from new and treated patients were subjected to conventional MIC and PST methods for ETO following standard operating procedures. With breakpoint concentration set at 114 and 156 µg/ml, an increase in specificity was observed whereas sensitivity was high with 80 µg/ml as breakpoint concentration. Errors due to false resistant and susceptible isolates were least at 80 µg/ml concentration. Performance parameters at 80 µg/ml breakpoint concentration indicated significant association between PST and MIC methods.

  10. A broad range assay for rapid detection and etiologic characterization of bacterial meningitis: performance testing in samples from sub-Sahara.

    PubMed

    Won, Helen; Yang, Samuel; Gaydos, Charlotte; Hardick, Justin; Ramachandran, Padmini; Hsieh, Yu-Hsiang; Kecojevic, Alexander; Njanpop-Lafourcade, Berthe-Marie; Mueller, Judith E; Tameklo, Tsidi Agbeko; Badziklou, Kossi; Gessner, Bradford D; Rothman, Richard E

    2012-09-01

    This study aimed to conduct a pilot evaluation of broad-based multiprobe polymerase chain reaction (PCR) in clinical cerebrospinal fluid (CSF) samples compared to local conventional PCR/culture methods used for bacterial meningitis surveillance. A previously described PCR consisting of initial broad-based detection of Eubacteriales by a universal probe, followed by Gram typing, and pathogen-specific probes was designed targeting variable regions of the 16S rRNA gene. The diagnostic performance of the 16S rRNA assay in "127 CSF samples was evaluated in samples from patients from Togo, Africa, by comparison to conventional PCR/culture methods. Our probes detected Neisseria meningitidis, Streptococcus pneumoniae, and Haemophilus influenzae. Uniprobe sensitivity and specificity versus conventional PCR were 100% and 54.6%, respectively. Sensitivity and specificity of uniprobe versus culture methods were 96.5% and 52.5%, respectively. Gram-typing probes correctly typed 98.8% (82/83) and pathogen-specific probes identified 96.4% (80/83) of the positives. This broad-based PCR algorithm successfully detected and provided species level information for multiple bacterial meningitis agents in clinical samples. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. A broad range assay for rapid detection and etiologic characterization of bacterial meningitis: performance testing in samples from sub-Sahara☆, ☆☆,★

    PubMed Central

    Won, Helen; Yang, Samuel; Gaydos, Charlotte; Hardick, Justin; Ramachandran, Padmini; Hsieh, Yu-Hsiang; Kecojevic, Alexander; Njanpop-Lafourcade, Berthe-Marie; Mueller, Judith E.; Tameklo, Tsidi Agbeko; Badziklou, Kossi; Gessner, Bradford D.; Rothman, Richard E.

    2012-01-01

    This study aimed to conduct a pilot evaluation of broad-based multiprobe polymerase chain reaction (PCR) in clinical cerebrospinal fluid (CSF) samples compared to local conventional PCR/culture methods used for bacterial meningitis surveillance. A previously described PCR consisting of initial broad-based detection of Eubacteriales by a universal probe, followed by Gram typing, and pathogen-specific probes was designed targeting variable regions of the 16S rRNA gene. The diagnostic performance of the 16S rRNA assay in “”127 CSF samples was evaluated in samples from patients from Togo, Africa, by comparison to conventional PCR/culture methods. Our probes detected Neisseria meningitidis, Streptococcus pneumoniae, and Haemophilus influenzae. Uniprobe sensitivity and specificity versus conventional PCR were 100% and 54.6%, respectively. Sensitivity and specificity of uniprobe versus culture methods were 96.5% and 52.5%, respectively. Gram-typing probes correctly typed 98.8% (82/83) and pathogen-specific probes identified 96.4% (80/83) of the positives. This broad-based PCR algorithm successfully detected and provided species level information for multiple bacterial meningitis agents in clinical samples. PMID:22809694

  12. Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes

    PubMed Central

    2014-01-01

    Background The purpose of this study was to compare two impression techniques from the perspective of patient preferences and treatment comfort. Methods Twenty-four (12 male, 12 female) subjects who had no previous experience with either conventional or digital impression participated in this study. Conventional impressions of maxillary and mandibular dental arches were taken with a polyether impression material (Impregum, 3 M ESPE), and bite registrations were made with polysiloxane bite registration material (Futar D, Kettenbach). Two weeks later, digital impressions and bite scans were performed using an intra-oral scanner (CEREC Omnicam, Sirona). Immediately after the impressions were made, the subjects’ attitudes, preferences and perceptions towards impression techniques were evaluated using a standardized questionnaire. The perceived source of stress was evaluated using the State-Trait Anxiety Scale. Processing steps of the impression techniques (tray selection, working time etc.) were recorded in seconds. Statistical analyses were performed with the Wilcoxon Rank test, and p < 0.05 was considered significant. Results There were significant differences among the groups (p < 0.05) in terms of total working time and processing steps. Patients stated that digital impressions were more comfortable than conventional techniques. Conclusions Digital impressions resulted in a more time-efficient technique than conventional impressions. Patients preferred the digital impression technique rather than conventional techniques. PMID:24479892

  13. Permeability evaluation after decay removal in primary teeth with current caries-excavation techniques.

    PubMed

    Shabzendedar, Mahbobeh; Moosavi, Horieh; Talbi, Maryam; Sharifi, Marjan

    2011-11-01

    The goal of the study was to evaluate the effect of caries removal by three various methods on the permeability of class II composite resin restorations in primary molar teeth. Forty-five recently extracted primary molars were randomly assigned to three groups for three different methods of caries removal; group 1-mechanical, group 2-caries detector dye, and group 3-Carisolv (n = 15). After that, class II cavities in all groups were restored with the adhesive (Opti Bond Solo Plus) that was applied according to the manufacturer's instruction and a posterior composite (Herculite XRV), which was used incrementally. After 24 hours the samples were thermocycled in water for 500 cycles between 5 and 55°C with a dwell time of 30 sec. Permeability was assessed by the fluid filtration method. The data were analyzed using the ANOVA test while study groups were compared with Tukey test for statistically significant differences at a 5% significance level. The evaluation of tested groups indicated that the highest (0.80) and least (0.37) mean of permeability was observed in group 2 and 3 respectively. Significant difference was revealed among the tested groups (p = 0.045). The comparison of Carisolv and caries detector dye groups indicated a statistically significant difference (p = 0.037). There was not any significant difference between Carisolv or caries dye in the conventional group. Using the chemomechanical and staining methods for caries removal had no more detrimental effect on permeability than the conventional technique. However, caries detection dye for caries removal could be more harmful than chemomechanical method. None of the current caries-excavation techniques could eliminate permeability in class II composite resin restorations. Furthermore, staining methods do not have an adverse effect on sealing ability in comparison to the conventional technique.

  14. Rapid Diagnosis of Bloodstream Infections with PCR Followed by Mass Spectrometry

    PubMed Central

    Jordana-Lluch, Elena; Carolan, Heather E.; Giménez, Montserrat; Sampath, Rangarajan; Ecker, David J.; Quesada, M. Dolores; Mòdol, Josep M.; Arméstar, Fernando; Blyn, Lawrence B.; Cummins, Lendell L.; Ausina, Vicente; Martró, Elisa

    2013-01-01

    Achieving a rapid microbiological diagnosis is crucial for decreasing morbidity and mortality of patients with a bloodstream infection, as it leads to the administration of an appropriate empiric antimicrobial therapy. Molecular methods may offer a rapid alternative to conventional microbiological diagnosis involving blood culture. In this study, the performance of a new technology that uses broad-spectrum PCR coupled with mass spectrometry (PCR/ESI-MS) was evaluated for the detection of microorganisms directly from whole blood. A total of 247 whole blood samples and paired blood cultures were prospectively obtained from 175 patients with a suspicion of sepsis. Both sample types were analyzed using the PCR/ESI-MS technology, and the results were compared with those obtained by conventional identification methods. The overall agreement between conventional methods and PCR/ESI-MS performed in blood culture aliquots was 94.2% with 96.8% sensitivity and 98.5% specificity for the molecular method. When comparing conventional methods with PCR/ESI-MS performed in whole blood specimens, the overall agreement was 77.1% with 50% sensitivity and 93.8% specificity for the molecular method. Interestingly, the PCR/ESI-MS technology led to the additional identification of 13 pathogens that were not found by conventional methods. Using the PCR/ESI-MS technology the microbiological diagnosis of bloodstream infections could be anticipated in about half of the patients in our setting, including a small but significant proportion of patients newly diagnosed. Thus, this promising technology could be very useful for the rapid diagnosis of sepsis in combination with traditional methods. PMID:23626775

  15. An ex vivo approach to botanical-drug interactions: A proof of concept study

    PubMed Central

    Wang, Xinwen; Zhu, Hao-Jie; Munoz, Juliana; Gurley, Bill J.; Markowitz, John S.

    2015-01-01

    Ethnopharmacological relevance Botanical medicines are frequently used in combination with therapeutic drugs, imposing a risk for harmful botanical-drug interactions (BDIs). Among the existing BDI evaluation methods, clinical studies are the most desirable, but due to their expense and protracted time-line for completion, conventional in vitro methodologies remain the most frequently used BDI assessment tools. However, many predictions generated from in vitro studies are inconsistent with clinical findings. Accordingly, the present study aimed to develop a novel ex vivo approach for BDI assessment and expand the safety evaluation methodoloy in applied ethnopharmacological research. Materials and Methods This approach differs from conventional in vitro methods in that rather than botanical extracts or individual phytochemicals being prepared in artificial buffers, human plasma/serum collected from a limited number of subjects administered botanical supplements was utilized to assess BDIs. To validate the methodology, human plasma/serum samples collected from healthy subjects administered either milk thistle or goldenseal extracts were utilized in incubation studies to determine their potential inhibitory effects on CYP2C9 and CYP3A4/5, respectively. Silybin A and B, two principal milk thistle phytochemicals, and hydrastine and berberine, the purported active constituents in goldenseal, were evaluated in both phosphate buffer and human plasma based in vitro incubation systems. Results Ex vivo study results were consistent with formal clinical study findings for the effect of milk thistle on the disposition of tolbutamide, a CYP2C9 substrate, and for goldenseal’s influence on the pharmacokinetics of midazolam, a widely accepted CYP3A4/5 substrate. Compared to conventional in vitro BDI methodologies of assessment, the introduction of human plasma into the in vitro study model changed the observed inhibitory effect of silybinA, silybin B and hydrastine and berberine on CYP2C9 and CYP3A4/5, respectively, results which more closely mirrored those generated in clinical study. Conclusions Data from conventional buffer-based in vitro studies were less predictive than the ex vivo assessments. Thus, this novel ex vivo approach may be more effective at predicting clinically relevant BDIs than conventional in vitro methods. PMID:25623616

  16. Integration of Biomass Harvesting and Site Preparation

    Treesearch

    Bryce J. Stokes; William F. Watson

    1986-01-01

    This study was conducted to assess the costs of various site preparation methods with various levels of harvesting Site impacts, soil compaction and disturbance were examined. Three hawesting methods rare evaluated in pine pulpwood plantation and pine sawtimber stands. The harvesting methods tested were (1) conventional - harvesting all roundwood. (2) two-pass - first...

  17. Fuzzy rule-based image segmentation in dynamic MR images of the liver

    NASA Astrophysics Data System (ADS)

    Kobashi, Syoji; Hata, Yutaka; Tokimoto, Yasuhiro; Ishikawa, Makato

    2000-06-01

    This paper presents a fuzzy rule-based region growing method for segmenting two-dimensional (2-D) and three-dimensional (3- D) magnetic resonance (MR) images. The method is an extension of the conventional region growing method. The proposed method evaluates the growing criteria by using fuzzy inference techniques. The use of the fuzzy if-then rules is appropriate for describing the knowledge of the legions on the MR images. To evaluate the performance of the proposed method, it was applied to artificially generated images. In comparison with the conventional method, the proposed method shows high robustness for noisy images. The method then applied for segmenting the dynamic MR images of the liver. The dynamic MR imaging has been used for diagnosis of hepatocellular carcinoma (HCC), portal hypertension, and so on. Segmenting the liver, portal vein (PV), and inferior vena cava (IVC) can give useful description for the diagnosis, and is a basis work of a pres-surgery planning system and a virtual endoscope. To apply the proposed method, fuzzy if-then rules are derived from the time-density curve of ROIs. In the experimental results, the 2-D reconstructed and 3-D rendered images of the segmented liver, PV, and IVC are shown. The evaluation by a physician shows that the generated images are comparable to the hepatic anatomy, and they would be useful to understanding, diagnosis, and pre-surgery planning.

  18. An Evaluation of Computer-Aided Instruction in an Introductory Biostatistics Course.

    ERIC Educational Resources Information Center

    Forsythe, Alan B.; Freed, James R.

    1979-01-01

    Evaluates the effectiveness of computer assisted instruction for teaching biostatistics to first year students at the UCLA School of Dentistry. Results do not demonstrate the superiority of CAI but do suggest that CAI compares favorably to conventional lecture and programed instruction methods. (RAO)

  19. Obstacles to Using Prior Research and Evaluations.

    ERIC Educational Resources Information Center

    Orwin, Robert G.

    1985-01-01

    The manner in which results and methods are reported influences the ability of the synthesis of prior studies for planning new evaluations. Confidence ratings, coding conventions, and supplemental evidence can partially overcome the difficulties. Planners must acknowledge the influence of their own judgement in using prior research. (Author)

  20. Pre-Then-Post Testing: A Tool To Improve the Accuracy of Management Training Program Evaluation.

    ERIC Educational Resources Information Center

    Mezoff, Bob

    1981-01-01

    Explains a procedure to avoid the detrimental biases of conventional self-reports of training outcomes. The evaluation format provided is a method for using statistical procedures to increase the accuracy of self-reports by overcoming response-shift-bias. (Author/MER)

  1. Influence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study

    PubMed Central

    Pereira, Graziane Olímpio; Gimenez, Carla Maria Melleiro; Prieto, Lucas; Prieto, Marcos Gabriel do Lago; Basting, Roberta Tarkany

    2016-01-01

    ABSTRACT Objective: To evaluate stainless steel archwire static friction in active and passive self-ligating lingual and conventional brackets with second-order angulations. Methods: Two conventional lingual brackets for canines (STb light/Ormco; PSWb/Tecnident), and two self-ligating brackets, one active (In-Ovation L/GAC) and the other passive (3D/ Forestadent), were evaluated. A stainless steel archwire was used at 0°, 3° and 5° angulations. Metal ligatures, conventional elastic ligatures, and low friction elastic ligatures were also tested. A universal testing machine applied friction between brackets and wires, simulating sliding mechanics, to produce 2-mm sliding at 3 mm/minute speed. Results: Two-way analysis of variance demonstrated a significant effect of the interaction between brackets and angulations (p < 0.001). Tukey test indicated that the highest frictional resistance values were observed at 5° angulation for In-Ovation L, PSWb bracket with non conventional ligature, and STb bracket with metal ligature. As for 3D, PSWb with conventional or metal ligatures, and STb brackets with non conventional ligature, showed significantly lower static frictional resistance with 0° angulation. At 0° angulation, STb brackets with metal ties, In-Ovation L brackets and 3D brackets had the lowest frictional resistance. Conclusions: As the angulation increased from 0° to 3°, static friction resistance increased. When angulation increased from 3° to 5°, static friction resistance increased or remained the same. Self-ligating 3D and In-Ovation L brackets, as well as conventional STb brackets, seem to be the best option when sliding mechanics is used to perform lingual orthodontic treatment. PMID:27653262

  2. Conventional plate fixation method versus pre-operative virtual simulation and three-dimensional printing-assisted contoured plate fixation method in the treatment of anterior pelvic ring fracture.

    PubMed

    Hung, Chun-Chi; Li, Yuan-Ta; Chou, Yu-Ching; Chen, Jia-En; Wu, Chia-Chun; Shen, Hsain-Chung; Yeh, Tsu-Te

    2018-05-03

    Treating pelvic fractures remains a challenging task for orthopaedic surgeons. We aimed to evaluate the feasibility, accuracy, and effectiveness of three-dimensional (3D) printing technology and computer-assisted virtual surgery for pre-operative planning in anterior ring fractures of the pelvis. We hypothesized that using 3D printing models would reduce operation time and significantly improve the surgical outcomes of pelvic fracture repair. We retrospectively reviewed the records of 30 patients with pelvic fractures treated by anterior pelvic fixation with locking plates (14 patients, conventional locking plate fixation; 16 patients, pre-operative virtual simulation with 3D, printing-assisted, pre-contoured, locking plate fixation). We compared operative time, instrumentation time, blood loss, and post-surgical residual displacements, as evaluated on X-ray films, among groups. Statistical analyses evaluated significant differences between the groups for each of these variables. The patients treated with the virtual simulation and 3D printing-assisted technique had significantly shorter internal fixation times, shorter surgery duration, and less blood loss (- 57 minutes, - 70 minutes, and - 274 ml, respectively; P < 0.05) than patients in the conventional surgery group. However, the post-operative radiological result was similar between groups (P > 0.05). The complication rate was less in the 3D printing group (1/16 patients) than in the conventional surgery group (3/14 patients). The 3D simulation and printing technique is an effective and reliable method for treating anterior pelvic ring fractures. With precise pre-operative planning and accurate execution of the procedures, this time-saving approach can provide a more personalized treatment plan, allowing for a safer orthopaedic surgery.

  3. Physical and chemical properties of orthodontic brackets after 12 and 24 months: in situ study.

    PubMed

    Mendes, Bernardo de Azevedo Bahia; Neto Ferreira, Ricardo Alberto; Pithon, Matheus Melo; Horta, Martinho Campolina Rebello; Oliveira, Dauro Douglas

    2014-06-01

    The aim of this article was to assess how intraoral biodegradation influenced the surface characteristics and friction levels of metallic brackets used during 12 and 24 months of orthodontic treatment and also to compare the static friction generated in these brackets with four different methods of the ligation of orthodontic wires. Seventy premolar brackets as received from the manufacturer and 224 brackets that were used in previous orthodontic treatments were evaluated in this experiment. The surface morphology and the composition of the deposits found in the brackets were evaluated with rugosimetry, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Friction was analyzed by applying tensile tests simulating sliding mechanics with a 0.019x0.025" steel wire. The static friction levels produced by the following ligation methods were evaluated: loosely attached steel ligature around all four bracket wings, steel ligature attached to only two wings, conventional elastomeric ligation around all 4 bracket wings, and non-conventional Slide® elastomeric ligature. The results demonstrated the presence of biodegradation effects such as corrosion pits, plastic deformation, cracks, and material deposits. The main chemical elements found on these deposits were Carbon and Oxygen. The maximum friction produced by each ligation method changed according to the time of intraoral use. The steel ligature loosely attached to all four bracket wings produced the lowest friction levels in the new brackets. The conventional elastic ligatures generated the highest friction levels. The metallic brackets underwent significant degradation during orthodontic treatment, showing an increase in surface roughness and the deposit of chemical elements on the surface. The levels of static friction decreased with use. The non-conventional elastic ligatures were the best alternative to reduce friction.

  4. Biological Activity of Conventional and Organic Pomegranate Juices: Antioxidant and Antimutagenic Potential.

    PubMed

    Cano-Lamadrid, M; Marhuenda-Egea, F C; Hernández, F; Rosas-Burgos, E C; Burgos-Hernández, A; Carbonell-Barrachina, A A

    2016-12-01

    None of the health claims about pomegranate juices has been approved yet by European Food Safety Authority (EFSA). There is a general perception among consumers that organic foods are healthier, tastier, and more nutritive than the conventional products. The aim of this research was to study the differences in the biological activity between ready-for-consumption juices obtained from pomegranates fruits grown under conventional and organic agricultural practices. Antioxidant activity has been evaluated by three methods (DPPH • , ABTS + , and FRAP), together with the total contents of phenolics and punicalagin (HPLC-DAD); besides, the Ames test was used to evaluate the antimutagenic potential of the juices. Pomegranate juice, either from conventionally or organically grown fruits, was antimutagenic (mean of 51 and 90 % for Salmonella typhimurium TA100 and TA98, respectively) and it was capable of protecting DNA from both, base-pair or frame-shift type of mutations. In fact, the antimutagenicity of conventional pomegranate juice was higher than that achieved by the organic sample; this finding was linked to a higher punicalagin content (201 and 104 mg L -1 for conventional and organic juices, respectively).

  5. In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions.

    PubMed

    Ender, Andreas; Mehl, Albert

    2015-01-01

    To investigate the accuracy of conventional and digital impression methods used to obtain full-arch impressions by using an in-vitro reference model. Eight different conventional (polyether, POE; vinylsiloxanether, VSE; direct scannable vinylsiloxanether, VSES; and irreversible hydrocolloid, ALG) and digital (CEREC Bluecam, CER; CEREC Omnicam, OC; Cadent iTero, ITE; and Lava COS, LAV) full-arch impressions were obtained from a reference model with a known morphology, using a highly accurate reference scanner. The impressions obtained were then compared with the original geometry of the reference model and within each test group. A point-to-point measurement of the surface of the model using the signed nearest neighbour method resulted in a mean (10%-90%)/2 percentile value for the difference between the impression and original model (trueness) as well as the difference between impressions within a test group (precision). Trueness values ranged from 11.5 μm (VSE) to 60.2 μm (POE), and precision ranged from 12.3 μm (VSE) to 66.7 μm (POE). Among the test groups, VSE, VSES, and CER showed the highest trueness and precision. The deviation pattern varied with the impression method. Conventional impressions showed high accuracy across the full dental arch in all groups, except POE and ALG. Conventional and digital impression methods show differences regarding full-arch accuracy. Digital impression systems reveal higher local deviations of the full-arch model. Digital intraoral impression systems do not show superior accuracy compared to highly accurate conventional impression techniques. However, they provide excellent clinical results within their indications applying the correct scanning technique.

  6. Rapid detection of rifampicin and isoniazid resistance in Mycobacterium tuberculosis by the direct thin-layer agar method.

    PubMed

    Robledo, J; Mejia, G I; Paniagua, L; Martin, A; Guzmán, A

    2008-12-01

    We evaluated thin-layer agar (TLA) for the detection of resistance of Mycobacterium tuberculosis to rifampicin (RMP) and isoniazid (INH) as a direct method in patients at risk of multidrug-resistant tuberculosis (MDR-TB). Quadrant TLA plates contain 7H10 Middlebrook growth control, para-nitrobenzoic acid, INH and RMP. Detection of RMP and INH resistance by TLA was compared to that in indirect conventional drug susceptibility testing (DST) and conventional culture media. Median time for growth was respectively 22, 10 and 7.6 days for Löwenstein-Jensen, TLA and the Mycobacterial Growth Indicator Tube. TLA sensitivity, specificity and predictive values for RMP and INH resistance were 100%. Time to resistance detection was respectively 11 and 11.5 days for RMP and INH. TLA showed a rapid turnaround time and performance comparable to conventional DST methods.

  7. Comparison of Tooth Color Change After Bleaching With Conventional and Different Light-Activated Methods.

    PubMed

    Shahabi, Sima; Assadian, Hadi; Mahmoudi Nahavandi, Alireza; Nokhbatolfoghahaei, Hanieh

    2018-01-01

    Introduction: The demand for esthetic dental treatments is increasing in recent years mainly due to improved oral hygiene and better maintenance of oral health and teeth in older individuals. Bleaching of discolored anterior teeth is the most popular among esthetic dental treatments. Even individuals with sound teeth and adequate esthetics seek to have whiter teeth in the anterior region. The aim of this study was to evaluate tooth color changes following conventional in-office bleaching techniques compared to light-activated methods using different light sources. Methods: Seventy sound anterior teeth (devoided of caries and/or fracture), extracted for periodontal and orthodontic reasons were selected and allocated to 7 groups: (A) control, (B) conventional bleaching (C) LED-activated bleaching, (D) KTP laser-activated bleaching, (E) diode laser-activated bleaching, (F) Nd:YAG laser-activated bleaching and (G) CO2 laser-activated bleaching. Colorimetric evaluation was carried out before and after treatment using a spectrophotoradiometer. Data were analyzed by one- and two-way analysis of variance (ANOVA) as well as multiple comparison methods. Results: The results showed that all bleaching procedures were effective in reducing the yellowness index. However, the KTP laser-activated bleaching was significantly more effective than the other techniques in 95% confidence level. It was also seen that CO2 laser activated method has outperformed groups E, F and G and the conventional bleaching without light activation was not effective at all and represented similar results with the control group. Furthermore, the groups E and G had almost the same results in decreasing the yellowness index. Conclusion: The results showed that all bleaching techniques were effective however, the KTP laser-activated bleaching was significantly more efficient, closely followed by the CO2 laser-activated bleaching technique.

  8. Comparison of shear test methods for evaluating the bond strength of resin cement to zirconia ceramic.

    PubMed

    Kim, Jae-Hoon; Chae, Soyeon; Lee, Yunhee; Han, Geum-Jun; Cho, Byeong-Hoon

    2014-11-01

    This study compared the sensitivity of three shear test methods for measuring the shear bond strength (SBS) of resin cement to zirconia ceramic and evaluated the effects of surface treatment methods on the bonding. Polished zirconia ceramic (Cercon base, DeguDent) discs were randomly divided into four surface treatment groups: no treatment (C), airborne-particle abrasion (A), conditioning with Alloy primer (Kuraray Medical Co.) (P) and conditioning with Alloy primer after airborne-particle abrasion (AP). The bond strengths of the resin cement (Multilink N, Ivoclar Vivadent) to the zirconia specimens of each surface treatment group were determined by three SBS test methods: the conventional SBS test with direct filling of the mold (Ø 4 mm × 3 mm) with resin cement (Method 1), the conventional SBS test with cementation of composite cylinders (Ø 4 mm × 3 mm) using resin cement (Method 2) and the microshear bond strength (μSBS) test with cementation of composite cylinders (Ø 0.8 mm × 1 mm) using resin cement (Method 3). Both the test method and the surface treatment significantly influenced the SBS values. In Method 3, as the SBS values increased, the coefficients of variation decreased and the Weibull parameters increased. The AP groups showed the highest SBS in all of the test methods. Only in Method 3 did the P group show a higher SBS than the A group. The μSBS test was more sensitive to differentiating the effects of surface treatment methods than the conventional SBS tests. Primer conditioning was a stronger contributing factor for the resin bond to zirconia ceramic than was airborne-particle abrasion.

  9. Web-Based Versus Conventional Training for Medical Students on Infant Gross Motor Screening.

    PubMed

    Pusponegoro, Hardiono D; Soebadi, Amanda; Surya, Raymond

    2015-12-01

    Early detection of developmental abnormalities is important for early intervention. A simple screening method is needed for use by general practitioners, as is an effective and efficient training method. This study aims to evaluate the effectiveness, acceptability, and usability of Web-based training for medical students on a simple gross motor screening method in infants. Fifth-year medical students at University of Indonesia in Jakarta were randomized into two groups. A Web-based training group received online video modules, discussions, and assessments (at www.schoology.com ). A conventional training group received a 1-day live training using the same module. Both groups completed identical pre- and posttests and the User Satisfaction Questionnaire (USQ). The Web-based group also completed the System Usability Scale (SUS). The module was based on a gross motor screening method used in the World Health Organization Multicentre Growth Reference Study. There were 39 and 32 subjects in the Web-based and conventional groups, respectively. Mean pretest versus posttest scores (correct answers out of 20) were 9.05 versus 16.95 (p=0.0001) in the Web-based group and 9.31 versus 16.88 (p=0.0001) in the conventional group. Mean difference between pre- and posttest scores did not differ significantly between the Web-based and conventional groups (mean [standard deviation], 7.56 [3.252] versus 7.90 [5.170]; p=0.741]. Both training methods were acceptable based on USQ scores. Based on SUS scores, the Web-based training had good usability. Web-based training is an effective, efficient, and acceptable training method for medical students on simple infant gross motor screening and is as effective as conventional training.

  10. Improving Arterial Spin Labeling by Using Deep Learning.

    PubMed

    Kim, Ki Hwan; Choi, Seung Hong; Park, Sung-Hong

    2018-05-01

    Purpose To develop a deep learning algorithm that generates arterial spin labeling (ASL) perfusion images with higher accuracy and robustness by using a smaller number of subtraction images. Materials and Methods For ASL image generation from pair-wise subtraction, we used a convolutional neural network (CNN) as a deep learning algorithm. The ground truth perfusion images were generated by averaging six or seven pairwise subtraction images acquired with (a) conventional pseudocontinuous arterial spin labeling from seven healthy subjects or (b) Hadamard-encoded pseudocontinuous ASL from 114 patients with various diseases. CNNs were trained to generate perfusion images from a smaller number (two or three) of subtraction images and evaluated by means of cross-validation. CNNs from the patient data sets were also tested on 26 separate stroke data sets. CNNs were compared with the conventional averaging method in terms of mean square error and radiologic score by using a paired t test and/or Wilcoxon signed-rank test. Results Mean square errors were approximately 40% lower than those of the conventional averaging method for the cross-validation with the healthy subjects and patients and the separate test with the patients who had experienced a stroke (P < .001). Region-of-interest analysis in stroke regions showed that cerebral blood flow maps from CNN (mean ± standard deviation, 19.7 mL per 100 g/min ± 9.7) had smaller mean square errors than those determined with the conventional averaging method (43.2 ± 29.8) (P < .001). Radiologic scoring demonstrated that CNNs suppressed noise and motion and/or segmentation artifacts better than the conventional averaging method did (P < .001). Conclusion CNNs provided superior perfusion image quality and more accurate perfusion measurement compared with those of the conventional averaging method for generation of ASL images from pair-wise subtraction images. © RSNA, 2017.

  11. Evaluating Sustainability of Cropland Use in Yuanzhou County of the Loess Plateau, China Using an Emergy-Based Ecological Footprint

    PubMed Central

    Bai, Xiaomei; Wen, Zhongming; An, Shaoshan; Li, Bicheng

    2015-01-01

    Evaluating the sustainability of cropland use is essential for guaranteeing a secure food supply and accomplishing agriculture sustainable development. This study was conducted in the ecologically vulnerable Loess Plateau region of China to evaluate the sustainability of cropland use based on an ecological footprint model that integrates emergy analysis. One modified method proposed in 2005 is known as the emergetic ecological footprint (EEF). We enhanced the method by accounting for both the surface soil energy in the carrying capacity calculation and the net topsoil loss for human consumption in the EF calculation. This paper evaluates whether the cropland of the study area was overloaded or sustainably managed during the period from 1981 to 2009. Toward this end, the final results obtained from EEF were compared to conventional EF and previous methods. The results showed that the cropland of Yuanzhou County has not been used sustainably since 1983, and the conventional EF analysis provided similar results. In contrast, a deficit did not appear during this time period when previous calculation methods of others were used. Additionally, the ecological sustainable index (ESI) from three models indicated that the recently used cropland system is unlikely to be unsustainable. PMID:25738289

  12. Modified short-term guinea pig sensitization tests for detecting contact allergens as an alternative to the conventional test.

    PubMed

    Yanagi, M; Hoya, M; Mori, M; Katsumura, Y

    2001-03-01

    The conventional adjuvant and patch test (APT) method of guinea pig sensitization testing was modified in 2 ways, s-APT and s-APT(2), in order to shorten the test period. These short-term test methods consist of 72-h closed application of test material with intradermal injection of emulsified Freund's complete adjuvant (E-FCA) for 1st induction, 48-h closed application of test material with (s-APT) or without (s-APT(2)) intradermal injection of E-FCA on the 7th day for 2nd induction, and open application on the 14th day for challenge. They were compared with conventional APT by using 8 allergenic chemicals (formaldehyde, nickel sulfate, cobalt sulfate, ethyl-p-aminobenzoate (benzocaine), isoeugenol, 2-mercaptobenzothiazole, 2,4-dinitrochlorobenzene (DNCB) and 1-phenylazo-2-naphthol (Sudan I)). The short-term methods gave similar results to those of conventional APT in terms of mean response, sensitization rate and sensitization potency (challenge concentration that induces a mean response equal to 1.0). Thus, our short-term methods, which are capable of evaluating skin sensitization within 17 days, are sufficiently sensitive to detect potentially hazardous contact allergens.

  13. In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques

    PubMed Central

    Kamimura, Emi; Tanaka, Shinpei; Takaba, Masayuki; Tachi, Keita; Baba, Kazuyoshi

    2017-01-01

    Purpose The aim of this study was to evaluate and compare the inter-operator reproducibility of three-dimensional (3D) images of teeth captured by a digital impression technique to a conventional impression technique in vivo. Materials and methods Twelve participants with complete natural dentition were included in this study. A digital impression of the mandibular molars of these participants was made by two operators with different levels of clinical experience, 3 or 16 years, using an intra-oral scanner (Lava COS, 3M ESPE). A silicone impression also was made by the same operators using the double mix impression technique (Imprint3, 3M ESPE). Stereolithography (STL) data were directly exported from the Lava COS system, while STL data of a plaster model made from silicone impression were captured by a three-dimensional (3D) laboratory scanner (D810, 3shape). The STL datasets recorded by two different operators were compared using 3D evaluation software and superimposed using the best-fit-algorithm method (least-squares method, PolyWorks, InnovMetric Software) for each impression technique. Inter-operator reproducibility as evaluated by average discrepancies of corresponding 3D data was compared between the two techniques (Wilcoxon signed-rank test). Results The visual inspection of superimposed datasets revealed that discrepancies between repeated digital impression were smaller than observed with silicone impression. Confirmation was forthcoming from statistical analysis revealing significantly smaller average inter-operator reproducibility using a digital impression technique (0.014± 0.02 mm) than when using a conventional impression technique (0.023 ± 0.01 mm). Conclusion The results of this in vivo study suggest that inter-operator reproducibility with a digital impression technique may be better than that of a conventional impression technique and is independent of the clinical experience of the operator. PMID:28636642

  14. Superiority of automatic remote monitoring compared with in-person evaluation for scheduled ICD follow-up in the TRUST trial - testing execution of the recommendations.

    PubMed

    Varma, Niraj; Michalski, Justin; Stambler, Bruce; Pavri, Behzad B

    2014-05-21

    To test recommended implantable cardioverter defibrillator (ICD) follow-up methods by 'in-person evaluations' (IPE) vs. 'remote Home Monitoring' (HM). ICD patients were randomized 2:1 to automatic HM or to Conventional monitoring, with follow-up checks scheduled at 3, 6, 9, 12, and 15 months post-implant. Conventional patients were evaluated with IPE only. Home Monitoring patients were assessed remotely only for 1 year between 3 and 15 month evaluations. Adherence to follow-up was measured. HM and Conventional patients were similar (age 63 years, 72% male, left ventricular ejection fraction 29%, primary prevention 73%, DDD 57%). Conventional management suffered greater patient attrition during the trial (20.1 vs. 14.2% in HM, P = 0.007). Three month follow-up occurred in 84% in both groups. There was 100% adherence (5 of 5 checks) in 47.3% Conventional vs. 59.7% HM (P < 0.001). Between 3 and 15 months, HM exhibited superior (2.2×) adherence to scheduled follow-up [incidence of failed follow up was 146 of 2421 (6.0%) in HM vs. 145 of 1098 (13.2%) in Conventional, P < 0.001] and punctuality. In HM (daily transmission success rate median 91%), transmission loss caused only 22 of 2275 (0.97%) failed HM evaluations between 3 and 15 months; others resulted from clinic oversight. Overall IPE failure rate in Conventional [193 of 1841 (10.5%) exceeded that in HM [97 of 1484 (6.5%), P < 0.001] by 62%, i.e. HM patients remained more loyal to IPE when this was mandated. Automatic remote monitoring better preserves patient retention and adherence to scheduled follow-up compared with IPE. NCT00336284. © The Author 2014. Published by Oxford University Press on behalf of the European Society of Cardiology.

  15. Reliability Evaluation Method with Weibull Distribution for Temporary Overvoltages of Substation Equipment

    NASA Astrophysics Data System (ADS)

    Okabe, Shigemitsu; Tsuboi, Toshihiro; Takami, Jun

    The power-frequency withstand voltage tests are regulated on electric power equipment in JEC by evaluating the lifetime reliability with a Weibull distribution function. The evaluation method is still controversial in terms of consideration of a plural number of faults and some alternative methods were proposed on this subject. The present paper first discusses the physical meanings of the various kinds of evaluating methods and secondly examines their effects on the power-frequency withstand voltage tests. Further, an appropriate method is investigated for an oil-filled transformer and a gas insulated switchgear with taking notice of dielectric breakdown or partial discharge mechanism under various insulating material and structure conditions and the tentative conclusion gives that the conventional method would be most pertinent under the present conditions.

  16. Comparative study on conventional, ultrasonication and microwave assisted extraction of γ-oryzanol from rice bran.

    PubMed

    Kumar, Pramod; Yadav, Devbrat; Kumar, Pradyuman; Panesar, Paramjeet Singh; Bunkar, Durga Shankar; Mishra, Diwaker; Chopra, H K

    2016-04-01

    In present study, conventional, ultrasonic and microwave assisted extraction methods were compared with the aim of optimizing best fitting solvent and method, solvent concentration and digestion time for high yield of γ-oryzanol from rice bran. Petroleum ether, hexane and methanol were used to prepare extracts. Extraction yield were evaluated for giving high crude oil yield, total phenolic content (TPC) and γ-oryzanol content. Gas chromatography-mass spectrophotometry was used for the determination of γ-oryzanol concentration. The highest concentration of γ-oryzanol was detected in methanolic extracts of microwave treatment (85.0 ppm) followed by ultrasonication (82.0 ppm) and conventional extraction method (73.5 ppm). Concentration of γ-oryzanol present in the extracts was found to be directly proportional to the total phenolic content. A combination of 80 % methanolic concentration and 55 minutes digestion time of microwave treatment yielded the best extraction method for TPC and thus γ-oryzanol (105 ppm).

  17. Impact Assessment and Environmental Evaluation of Various Ammonia Production Processes

    NASA Astrophysics Data System (ADS)

    Bicer, Yusuf; Dincer, Ibrahim; Vezina, Greg; Raso, Frank

    2017-05-01

    In the current study, conventional resources-based ammonia generation routes are comparatively studied through a comprehensive life cycle assessment. The selected ammonia generation options range from mostly used steam methane reforming to partial oxidation of heavy oil. The chosen ammonia synthesis process is the most common commercially available Haber-Bosch process. The essential energy input for the methods are used from various conventional resources such as coal, nuclear, natural gas and heavy oil. Using the life cycle assessment methodology, the environmental impacts of selected methods are identified and quantified from cradle to gate. The life cycle assessment outcomes of the conventional resources based ammonia production routes show that nuclear electrolysis-based ammonia generation method yields the lowest global warming and climate change impacts while the coal-based electrolysis options bring higher environmental problems. The calculated greenhouse gas emission from nuclear-based electrolysis is 0.48 kg CO2 equivalent while it is 13.6 kg CO2 per kg of ammonia for coal-based electrolysis method.

  18. Impact Assessment and Environmental Evaluation of Various Ammonia Production Processes.

    PubMed

    Bicer, Yusuf; Dincer, Ibrahim; Vezina, Greg; Raso, Frank

    2017-05-01

    In the current study, conventional resources-based ammonia generation routes are comparatively studied through a comprehensive life cycle assessment. The selected ammonia generation options range from mostly used steam methane reforming to partial oxidation of heavy oil. The chosen ammonia synthesis process is the most common commercially available Haber-Bosch process. The essential energy input for the methods are used from various conventional resources such as coal, nuclear, natural gas and heavy oil. Using the life cycle assessment methodology, the environmental impacts of selected methods are identified and quantified from cradle to gate. The life cycle assessment outcomes of the conventional resources based ammonia production routes show that nuclear electrolysis-based ammonia generation method yields the lowest global warming and climate change impacts while the coal-based electrolysis options bring higher environmental problems. The calculated greenhouse gas emission from nuclear-based electrolysis is 0.48 kg CO 2 equivalent while it is 13.6 kg CO 2 per kg of ammonia for coal-based electrolysis method.

  19. The Ultimate Pile Bearing Capacity from Conventional and Spectral Analysis of Surface Wave (SASW) Measurements

    NASA Astrophysics Data System (ADS)

    Faizah Bawadi, Nor; Anuar, Shamilah; Rahim, Mustaqqim A.; Mansor, A. Faizal

    2018-03-01

    A conventional and seismic method for determining the ultimate pile bearing capacity was proposed and compared. The Spectral Analysis of Surface Wave (SASW) method is one of the non-destructive seismic techniques that do not require drilling and sampling of soils, was used in the determination of shear wave velocity (Vs) and damping (D) profile of soil. The soil strength was found to be directly proportional to the Vs and its value has been successfully applied to obtain shallow bearing capacity empirically. A method is proposed in this study to determine the pile bearing capacity using Vs and D measurements for the design of pile and also as an alternative method to verify the bearing capacity from the other conventional methods of evaluation. The objectives of this study are to determine Vs and D profile through frequency response data from SASW measurements and to compare pile bearing capacities obtained from the method carried out and conventional methods. All SASW test arrays were conducted near the borehole and location of conventional pile load tests. In obtaining skin and end bearing pile resistance, the Hardin and Drnevich equation has been used with reference strains obtained from the method proposed by Abbiss. Back analysis results of pile bearing capacities from SASW were found to be 18981 kN and 4947 kN compared to 18014 kN and 4633 kN of IPLT with differences of 5% and 6% for Damansara and Kuala Lumpur test sites, respectively. The results of this study indicate that the seismic method proposed in this study has the potential to be used in estimating the pile bearing capacity.

  20. AN EVALUATION OF THREE CONVENTIONAL HISTOLOGICAL TECHNIQUES FOR STAINING THE CERATA OF CRATENA PILATA

    EPA Science Inventory

    Fixation and staining methods for different types of tissue in the marine nudibranch Cratena pilata were evaluated. Cratena pilata, a marine snail in the Phylum Mollusca, has the ability to take stinging cells, called nematocysts, from ingested animals belonging to another phylum...

  1. How to Study Chronic Diseases-Implications of the Convention on the Rights of Persons with Disabilities for Research Designs.

    PubMed

    von Peter, Sebastian; Bieler, Patrick

    2017-01-01

    The Convention on the Rights of Persons with Disabilities (CRPD) has been received considerable attention internationally. The Convention's main arguments are conceptually analyzed. Implications for the development of research designs are elaborated upon. The Convention entails both a human rights and a sociopolitical dimension. Advancing a relational notion of disability, it enters a rather foreign terrain to medical sciences. Research designs have to be changed accordingly. Research designs in accordance with the CRPD should employ and further develop context-sensitive research strategies and interdisciplinary collaboration. Complex designs that allow for a relational analysis of personalized effects have to be established and evaluated, thereby systematically integrating qualitative methods.

  2. Epidemiologic research using probabilistic outcome definitions.

    PubMed

    Cai, Bing; Hennessy, Sean; Lo Re, Vincent; Small, Dylan S

    2015-01-01

    Epidemiologic studies using electronic healthcare data often define the presence or absence of binary clinical outcomes by using algorithms with imperfect specificity, sensitivity, and positive predictive value. This results in misclassification and bias in study results. We describe and evaluate a new method called probabilistic outcome definition (POD) that uses logistic regression to estimate the probability of a clinical outcome using multiple potential algorithms and then uses multiple imputation to make valid inferences about the risk ratio or other epidemiologic parameters of interest. We conducted a simulation to evaluate the performance of the POD method with two variables that can predict the true outcome and compared the POD method with the conventional method. The simulation results showed that when the true risk ratio is equal to 1.0 (null), the conventional method based on a binary outcome provides unbiased estimates. However, when the risk ratio is not equal to 1.0, the traditional method, either using one predictive variable or both predictive variables to define the outcome, is biased when the positive predictive value is <100%, and the bias is very severe when the sensitivity or positive predictive value is poor (less than 0.75 in our simulation). In contrast, the POD method provides unbiased estimates of the risk ratio both when this measure of effect is equal to 1.0 and not equal to 1.0. Even when the sensitivity and positive predictive value are low, the POD method continues to provide unbiased estimates of the risk ratio. The POD method provides an improved way to define outcomes in database research. This method has a major advantage over the conventional method in that it provided unbiased estimates of risk ratios and it is easy to use. Copyright © 2014 John Wiley & Sons, Ltd.

  3. Calculations, and comparison with an ideal minimum, of trimmed drag for conventional and canard configurations having various levels of static stability

    NASA Technical Reports Server (NTRS)

    Mclaughlin, M. D.

    1977-01-01

    Classical drag equations were used to calculate total and induced drag and ratios of stabilizer lift to wing lift for a variety of conventional and canard configurations. The Flight efficiencies of such configurations that are trimmed in pitch and have various values of static margin are evaluated. Classical calculation methods are compared with more modern lifting surface theory.

  4. A smart rotary technique versus conventional pulpectomy for primary teeth: A randomized controlled clinical study

    PubMed Central

    Mokhtari, Negar; Shirazi, Alireza-Sarraf

    2017-01-01

    Background Techniques with adequate accuracy of working length determination along with shorter duration of treatment in pulpectomy procedure seems to be essential in pediatric dentistry. The aim of the present study was to evaluate the accuracy of root canal length measurement with Root ZX II apex locator and rotary system in pulpectomy of primary teeth. Material and Methods In this randomized control clinical trial complete pulpectomy was performed on 80 mandibular primary molars in 80, 4-6-year-old children. The study population was randomly divided into case and control groups. In control group conventional pulpectomy was performed and in the case group working length was determined by electronic apex locator Root ZXII and instrumented with Mtwo rotary files. Statistical evaluation was performed using Mann-Whitney and Chi-Square tests (P<0.05). Results There were no significant differences between electronic apex locator Root ZXII and conventional method in accuracy of root canal length determination. However significantly less time was needed for instrumenting with rotary files (P=0.000). Conclusions Considering the comparable results in accuracy of root canal length determination and the considerably shorter instrumentation time in Root ZXII apex locator and rotary system, it may be suggested for pulpectomy in primary molar teeth. Key words:Rotary technique, conventional technique, pulpectomy, primary teeth. PMID:29302280

  5. A Field Evaluation of the Hardy TB MODS Kit™ for the Rapid Phenotypic Diagnosis of Tuberculosis and Multi-Drug Resistant Tuberculosis

    PubMed Central

    Martin, Laura; Coronel, Jorge; Faulx, Dunia; Valdez, Melissa; Metzler, Mutsumi; Crudder, Chris; Castillo, Edith; Caviedes, Luz; Grandjean, Louis; Rodriguez, Mitzi; Friedland, Jon S.; Gilman, Robert H.; Moore, David A. J.

    2014-01-01

    Background Even though the WHO-endorsed, non-commercial MODS assay offers rapid, reliable TB liquid culture and phenotypic drug susceptibility testing (DST) at lower cost than any other diagnostic, uptake has been patchy. In part this reflects misperceptions about in-house assay quality assurance, but user convenience of one-stop procurement is also important. A commercial MODS kit was developed by Hardy Diagnostics (Santa Maria, CA, USA) with PATH (Seattle, WA, USA) to facilitate procurement, simplify procedures through readymade media, and enhance safety with a sealing silicone plate lid. Here we report the results from a large-scale field evaluation of the MODS kit in a government service laboratory. Methods & Findings 2446 sputum samples were cultured in parallel in Lowenstein-Jensen (LJ), conventional MODS and in the MODS kit. MODS kit DST was compared with conventional MODS (direct) DST and proportion method (indirect) DST. 778 samples (31.8%) were Mycobacterium tuberculosis culture-positive. Compared to conventional MODS the sensitivity, specificity, positive, and negative predictive values (95% confidence intervals) of the MODS Kit were 99.3% (98.3–99.8%), 98.3% (97.5–98.8%), 95.8% (94.0–97.1%), and 99.7% (99.3–99.9%). Median (interquartile ranges) time to culture-positivity (and rifampicin and isoniazid DST) was 10 (9–13) days for conventional MODS and 8.5 (7–11) for MODS Kit (p<0.01). Direct rifampicin and isoniazid DST in MODS kit was almost universally concordant with conventional MODS (97.9% agreement, 665/679 evaluable samples) and reference indirect DST (97.9% agreement, 687/702 evaluable samples). Conclusions MODS kit delivers performance indistinguishable from conventional MODS and offers a convenient, affordable alternative with enhanced safety from the sealing silicone lid. The availability in the marketplace of this platform, which conforms to European standards (CE-marked), readily repurposed for second-line DST in the near future, provides a fresh opportunity for improving equity of access to TB diagnosis and first and second-line DST in settings where the need is greatest. PMID:25225802

  6. Simultaneous HPLC determination of flavonoids and phenolic acids profile in Pêra-Rio orange juice.

    PubMed

    Mesquita, E; Monteiro, M

    2018-04-01

    The aim of this study was to develop and validate an HPLC-DAD method to evaluate the phenolic compounds profile of organic and conventional Pêra-Rio orange juice. The proposed method was validated for 10 flavonoids and 6 phenolic acids. A wide linear range (0.01-223.4μg·g -1 ), good accuracy (79.5-129.2%) and precision (CV≤3.8%), low limits of detection (1-22ng·g -1 ) and quantification (0.7-7.4μg), and overall ruggedness were attained. Good recovery was achieved for all phenolic compounds after extraction and cleanup. The method was applied to organic and conventional Pêra-Rio orange juices from beginning, middle and end of the 2016 harvest. Flavones rutin, nobiletin and tangeretin, and flavanones hesperidin, narirutin and eriocitrin were identified and quantified in all organic and conventional juices. Identity was confirmed by mass spectrometry. Nineteen non-identified phenolic compounds were quantified based on DAD spectra characteristic of the chemical class: 7 cinnamic acid derivatives, 6 flavanones and 6 flavones. The phenolic compounds profile of Pêra-Rio orange juices changed during the harvest; levels increased in organic orange juices, and decreased or were about the same in conventional orange juices. Phenolic compounds levels were higher in organic (0.5-1143.7mg·100g -1 ) than in conventional orange juices (0.5-689.7mg·100g -1 ). PCA differentiated organic from conventional FS and NFC juices, and conventional FCOJ from conventional FS and NFC juices, thus differentiating cultivation and processing. Copyright © 2017. Published by Elsevier Ltd.

  7. Oxygen utilization of the human left ventricle - An indirect method for its evaluation and clinical considerations

    NASA Technical Reports Server (NTRS)

    Ghista, D. N.; Sandler, H.

    1974-01-01

    An analytical method is presented for determining the oxygen consumption rate of the intact heart working (as opposed to empty but beating) human left ventricle. Use is made of experimental recordings obtained for the chamber pressure and the associated dimensions of the LV. LV dimensions are determined by cineangiocardiography, and the chamber pressure is obtained by means of fluid-filled catheters during retrograde or transeptal catheterization. An analytical method incorporating these data is then employed for the evaluation of the LV coronary oxygen consumption in five subjects. Oxygen consumption for these subjects was also obtained by the conventional clinical method in order to evaluate the reliability of the proposed method.

  8. A new method and device of aligning patient setup lasers in radiation therapy

    PubMed Central

    Hwang, Ui‐Jung; Jo, Kwanghyun; Kwak, Jung Won; Choi, Sang Hyoun; Jeong, Chiyoung; Kim, Mi Young; Jeong, Jong Hwi; Shin, Dongho; Lee, Se Byeong; Park, Jeong‐Hoon; Park, Sung Yong; Kim, Siyong

    2016-01-01

    The aim of this study is to develop a new method to align the patient setup lasers in a radiation therapy treatment room and examine its validity and efficiency. The new laser alignment method is realized by a device composed of both a metallic base plate and a few acrylic transparent plates. Except one, every plate has either a crosshair line (CHL) or a single vertical line that is used for alignment. Two holders for radiochromic film insertion are prepared in the device to find a radiation isocenter. The right laser positions can be found optically by matching the shadows of all the CHLs in the gantry head and the device. The reproducibility, accuracy, and efficiency of laser alignment and the dependency on the position error of the light source were evaluated by comparing the means and the standard deviations of the measured laser positions. After the optical alignment of the lasers, the radiation isocenter was found by the gantry and collimator star shots, and then the lasers were translated parallel to the isocenter. In the laser position reproducibility test, the mean and standard deviation on the wall of treatment room were 32.3±0.93 mm for the new method whereas they were 33.4±1.49 mm for the conventional method. The mean alignment accuracy was 1.4 mm for the new method, and 2.1 mm for the conventional method on the walls. In the test of the dependency on the light source position error, the mean laser position was shifted just by a similar amount of the shift of the light source in the new method, but it was greatly magnified in the conventional method. In this study, a new laser alignment method was devised and evaluated successfully. The new method provided more accurate, more reproducible, and faster alignment of the lasers than the conventional method. PACS numbers: 87.56.Fc, 87.53.Bn, 87.53.Kn, 87.53.Ly, 87.55.Gh PMID:26894331

  9. Evaluation of interactive teaching for undergraduate medical students using a classroom interactive response system in India.

    PubMed

    Datta, Rakesh; Datta, Karuna; Venkatesh, M D

    2015-07-01

    The classical didactic lecture has been the cornerstone of the theoretical undergraduate medical education. Their efficacy however reduces due to reduced interaction and short attention span of the students. It is hypothesized that the interactive response pad obviates some of these drawbacks. The aim of this study was to evaluate the effectiveness of an interactive response system by comparing it with conventional classroom teaching. A prospective comparative longitudinal study was conducted on 192 students who were exposed to either conventional or interactive teaching over 20 classes. Pre-test, Post-test and retentions test (post 8-12 weeks) scores were collated and statistically analysed. An independent observer measured number of student interactions in each class. Pre-test scores from both groups were similar (p = 0.71). There was significant improvement in both post test scores when compared to pre-test scores in either method (p < 0.001). The interactive post-test score was better than conventional post test score (p < 0.001) by 8-10% (95% CI-difference of means - 8.2%-9.24%-10.3%). The interactive retention test score was better than conventional retention test score (p < 0.001) by 15-18% (95% CI-difference of means - 15.0%-16.64%-18.2%). There were 51 participative events in the interactive group vs 25 in the conventional group. The Interactive Response Pad method was efficacious in teaching. Students taught with the interactive method were likely to score 8-10% higher (statistically significant) in the immediate post class time and 15-18% higher (statistically significant) after 8-12 weeks. The number of student-teacher interactions increases when using the interactive response pads.

  10. Research on Novel Algorithms for Smart Grid Reliability Assessment and Economic Dispatch

    NASA Astrophysics Data System (ADS)

    Luo, Wenjin

    In this dissertation, several studies of electric power system reliability and economy assessment methods are presented. To be more precise, several algorithms in evaluating power system reliability and economy are studied. Furthermore, two novel algorithms are applied to this field and their simulation results are compared with conventional results. As the electrical power system develops towards extra high voltage, remote distance, large capacity and regional networking, the application of a number of new technique equipments and the electric market system have be gradually established, and the results caused by power cut has become more and more serious. The electrical power system needs the highest possible reliability due to its complication and security. In this dissertation the Boolean logic Driven Markov Process (BDMP) method is studied and applied to evaluate power system reliability. This approach has several benefits. It allows complex dynamic models to be defined, while maintaining its easy readability as conventional methods. This method has been applied to evaluate IEEE reliability test system. The simulation results obtained are close to IEEE experimental data which means that it could be used for future study of the system reliability. Besides reliability, modern power system is expected to be more economic. This dissertation presents a novel evolutionary algorithm named as quantum evolutionary membrane algorithm (QEPS), which combines the concept and theory of quantum-inspired evolutionary algorithm and membrane computation, to solve the economic dispatch problem in renewable power system with on land and offshore wind farms. The case derived from real data is used for simulation tests. Another conventional evolutionary algorithm is also used to solve the same problem for comparison. The experimental results show that the proposed method is quick and accurate to obtain the optimal solution which is the minimum cost for electricity supplied by wind farm system.

  11. Super-resolution convolutional neural network for the improvement of the image quality of magnified images in chest radiographs

    NASA Astrophysics Data System (ADS)

    Umehara, Kensuke; Ota, Junko; Ishimaru, Naoki; Ohno, Shunsuke; Okamoto, Kentaro; Suzuki, Takanori; Shirai, Naoki; Ishida, Takayuki

    2017-02-01

    Single image super-resolution (SR) method can generate a high-resolution (HR) image from a low-resolution (LR) image by enhancing image resolution. In medical imaging, HR images are expected to have a potential to provide a more accurate diagnosis with the practical application of HR displays. In recent years, the super-resolution convolutional neural network (SRCNN), which is one of the state-of-the-art deep learning based SR methods, has proposed in computer vision. In this study, we applied and evaluated the SRCNN scheme to improve the image quality of magnified images in chest radiographs. For evaluation, a total of 247 chest X-rays were sampled from the JSRT database. The 247 chest X-rays were divided into 93 training cases with non-nodules and 152 test cases with lung nodules. The SRCNN was trained using the training dataset. With the trained SRCNN, the HR image was reconstructed from the LR one. We compared the image quality of the SRCNN and conventional image interpolation methods, nearest neighbor, bilinear and bicubic interpolations. For quantitative evaluation, we measured two image quality metrics, peak signal-to-noise ratio (PSNR) and structural similarity (SSIM). In the SRCNN scheme, PSNR and SSIM were significantly higher than those of three interpolation methods (p<0.001). Visual assessment confirmed that the SRCNN produced much sharper edge than conventional interpolation methods without any obvious artifacts. These preliminary results indicate that the SRCNN scheme significantly outperforms conventional interpolation algorithms for enhancing image resolution and that the use of the SRCNN can yield substantial improvement of the image quality of magnified images in chest radiographs.

  12. MRI Volume Fusion Based on 3D Shearlet Decompositions.

    PubMed

    Duan, Chang; Wang, Shuai; Wang, Xue Gang; Huang, Qi Hong

    2014-01-01

    Nowadays many MRI scans can give 3D volume data with different contrasts, but the observers may want to view various contrasts in the same 3D volume. The conventional 2D medical fusion methods can only fuse the 3D volume data layer by layer, which may lead to the loss of interframe correlative information. In this paper, a novel 3D medical volume fusion method based on 3D band limited shearlet transform (3D BLST) is proposed. And this method is evaluated upon MRI T2* and quantitative susceptibility mapping data of 4 human brains. Both the perspective impression and the quality indices indicate that the proposed method has a better performance than conventional 2D wavelet, DT CWT, and 3D wavelet, DT CWT based fusion methods.

  13. Rapid identification of pathogens directly from blood culture bottles by Bruker matrix-assisted laser desorption laser ionization-time of flight mass spectrometry versus routine methods.

    PubMed

    Jamal, Wafaa; Saleem, Rola; Rotimi, Vincent O

    2013-08-01

    The use of matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) for identification of microorganisms directly from blood culture is an exciting dimension to the microbiologists. We evaluated the performance of Bruker SepsiTyper kit™ (STK) for direct identification of bacteria from positive blood culture. This was done in parallel with conventional methods. Nonrepetitive positive blood cultures from 160 consecutive patients were prospectively evaluated by both methods. Of 160 positive blood cultures, the STK identified 114 (75.6%) isolates and routine conventional method 150 (93%). Thirty-six isolates were misidentified or not identified by the kit. Of these, 5 had score of >2.000 and 31 had an unreliable low score of <1.7. Four of 8 yeasts were identified correctly. The average turnaround time using the STK was 35 min, including extraction steps and 30:12 to 36:12 h with routine method. The STK holds promise for timely management of bacteremic patients. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. A Multi-level Fuzzy Evaluation Method for Smart Distribution Network Based on Entropy Weight

    NASA Astrophysics Data System (ADS)

    Li, Jianfang; Song, Xiaohui; Gao, Fei; Zhang, Yu

    2017-05-01

    Smart distribution network is considered as the future trend of distribution network. In order to comprehensive evaluate smart distribution construction level and give guidance to the practice of smart distribution construction, a multi-level fuzzy evaluation method based on entropy weight is proposed. Firstly, focus on both the conventional characteristics of distribution network and new characteristics of smart distribution network such as self-healing and interaction, a multi-level evaluation index system which contains power supply capability, power quality, economy, reliability and interaction is established. Then, a combination weighting method based on Delphi method and entropy weight method is put forward, which take into account not only the importance of the evaluation index in the experts’ subjective view, but also the objective and different information from the index values. Thirdly, a multi-level evaluation method based on fuzzy theory is put forward. Lastly, an example is conducted based on the statistical data of some cites’ distribution network and the evaluation method is proved effective and rational.

  15. Comparative performance of conventional OPC concrete and HPC designed by densified mixture design algorithm

    NASA Astrophysics Data System (ADS)

    Huynh, Trong-Phuoc; Hwang, Chao-Lung; Yang, Shu-Ti

    2017-12-01

    This experimental study evaluated the performance of normal ordinary Portland cement (OPC) concrete and high-performance concrete (HPC) that were designed by the conventional method (ACI) and densified mixture design algorithm (DMDA) method, respectively. Engineering properties and durability performance of both the OPC and HPC samples were studied using the tests of workability, compressive strength, water absorption, ultrasonic pulse velocity, and electrical surface resistivity. Test results show that the HPC performed good fresh property and further showed better performance in terms of strength and durability as compared to the OPC.

  16. Comparing the Effectiveness of Self-Learning Java Workshops with Traditional Classrooms

    ERIC Educational Resources Information Center

    Eranki, Kiran L. N.; Moudgalya, Kannan M.

    2016-01-01

    In this work, we study the effectiveness of a method called Spoken Tutorial, which is a candidate technique for self-learning. The performance of college students who self-learned Java through the Spoken Tutorial method is found to be better than that of conventional learners. Although the method evaluated in this work helps both genders, females…

  17. In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques.

    PubMed

    Kamimura, Emi; Tanaka, Shinpei; Takaba, Masayuki; Tachi, Keita; Baba, Kazuyoshi

    2017-01-01

    The aim of this study was to evaluate and compare the inter-operator reproducibility of three-dimensional (3D) images of teeth captured by a digital impression technique to a conventional impression technique in vivo. Twelve participants with complete natural dentition were included in this study. A digital impression of the mandibular molars of these participants was made by two operators with different levels of clinical experience, 3 or 16 years, using an intra-oral scanner (Lava COS, 3M ESPE). A silicone impression also was made by the same operators using the double mix impression technique (Imprint3, 3M ESPE). Stereolithography (STL) data were directly exported from the Lava COS system, while STL data of a plaster model made from silicone impression were captured by a three-dimensional (3D) laboratory scanner (D810, 3shape). The STL datasets recorded by two different operators were compared using 3D evaluation software and superimposed using the best-fit-algorithm method (least-squares method, PolyWorks, InnovMetric Software) for each impression technique. Inter-operator reproducibility as evaluated by average discrepancies of corresponding 3D data was compared between the two techniques (Wilcoxon signed-rank test). The visual inspection of superimposed datasets revealed that discrepancies between repeated digital impression were smaller than observed with silicone impression. Confirmation was forthcoming from statistical analysis revealing significantly smaller average inter-operator reproducibility using a digital impression technique (0.014± 0.02 mm) than when using a conventional impression technique (0.023 ± 0.01 mm). The results of this in vivo study suggest that inter-operator reproducibility with a digital impression technique may be better than that of a conventional impression technique and is independent of the clinical experience of the operator.

  18. Antioxidant potential of mulberry and non-mulberry silk sericin and its implications in biomedicine.

    PubMed

    Kumar, Jadi Praveen; Mandal, Biman B

    2017-07-01

    Sericin, a principal constituent of silk, is widely used in various biomedical applications. In addition, conferring protection against free radicals and oxidative damage add more value to its therapeutic potential. However, the antioxidant (AO) properties of silk sericin (SS) remains contingent on extraction procedures. In the present study, we have evaluated the effect of different extraction methods (conventional, autoclaving, urea, alkali and acid-degradation) on AO properties of SS from three Indian silk varieties [Antheraea assamensis (AA), Philosamia ricini (PR) and Bombyx mori (BM)]. The physico-chemical characterization studies revealed that the molecular weight of SS isolates of each method ranged from 10 to 220kDa along with varied protein structural biochemistry. SS extracts using urea-degradation (BM, PR and AA), conventional method and alkali-degradation (BM) displayed high percentage of β-sheets, random coils and turns. Acid-degraded SS (PR, followed by AA and BM) showed the highest total flavonoid content while conventional method (PR), autoclaving (AA) and alkali-degradation (BM) displayed lowest flavonoid levels. Interestingly, SS extracted by autoclaving (BM and AA), acid-degradation (PR), conventional and alkali-degradation (BM, AA and PR) methods exhibited 50% reduction of 2, 2-diphenyl-1-picrylhydrazyl (DPPH) radical. Moreover, the efficacy of antioxidant potential of SS extracted by different methods was found to be in the order of "alkali>autoclaving>conventional" as demonstrated in L929 cells. Correspondingly, the anti-lipid peroxidation activity of SS extracted by alkali method (AA, BM and PR) further confirmed better AO properties amid others. Thus, the present study demonstrates that the extraction methods may significantly affect AO activity of SS which might be of importance for potential cosmetic applications. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Cat-eye effect target recognition with single-pixel detectors

    NASA Astrophysics Data System (ADS)

    Jian, Weijian; Li, Li; Zhang, Xiaoyue

    2015-12-01

    A prototype of cat-eye effect target recognition with single-pixel detectors is proposed. Based on the framework of compressive sensing, it is possible to recognize cat-eye effect targets by projecting a series of known random patterns and measuring the backscattered light with three single-pixel detectors in different locations. The prototype only requires simpler, less expensive detectors and extends well beyond the visible spectrum. The simulations are accomplished to evaluate the feasibility of the proposed prototype. We compared our results to that obtained from conventional cat-eye effect target recognition methods using area array sensor. The experimental results show that this method is feasible and superior to the conventional method in dynamic and complicated backgrounds.

  20. Piezosurgery prevents brain tissue damage: an experimental study on a new rat model.

    PubMed

    Pavlíková, G; Foltán, R; Burian, M; Horká, E; Adámek, S; Hejčl, A; Hanzelka, T; Sedý, J

    2011-08-01

    Piezosurgery is a promising meticulous system for bone cutting, based on ultrasound microvibrations. It is thought that the impact of piezosurgery on the integrity of soft tissue is generally low, but it has not been examined critically. The authors undertook an experimental study to evaluate the brain tissue response to skull bone removal using piezosurgery compared with a conventional drilling method. In Wistar male rats, a circular bone window was drilled to the parietal bone using piezosurgery on one side and a conventional bone drill on the other side. The behavioural performance of animals was evaluated using the motor BBB test and sensory plantar test. The brains of animals were evaluated by magnetic resonance imaging (MRI) and histology. The results of MRI showed significantly increased depth and width of the brain lesion in the region of conventional drilling compared with the region where piezosurgery was used. Cresylviolet and NF 160 staining confirmed these findings. There was no significant difference in any of the behavioural tests between the two groups. In conclusion, piezosurgery is a safe method for the performance of osteotomy in close relation to soft tissue, including an extremely injury-sensitive tissue such as brain. Copyright © 2011 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Using Marine and Freshwater Fish Environmental Intelligence Networks Under Different Climate Change Scenarios to Evaluate the Effectiveness of the Minamata Convention on Mercury

    NASA Astrophysics Data System (ADS)

    Bank, M. S.

    2017-12-01

    The Minamata Convention on Mercury was recently ratified and will go into effect on August 16, 2017. As noted in the convention text, fish are an important source of nutrition to consumers worldwide and several marine and freshwater species represent important links in the global source-receptor dynamics of methylmercury. However, despite its importance, a coordinated global program for marine and freshwater fish species using accredited laboratories, reproducible data and reliable models is still lacking. In recent years fish mercury science has evolved significantly with its use of advanced technologies and computational models to address this complex and ubiquitous environmental and public health issue. These advances in the field have made it essential that transparency be enhanced to ensure that fish mercury studies used in support of the convention are truly reproducible and scientifically sound. One primary goal of this presentation is to evaluate fish bioinformatics and methods, results and inferential reproducibility as it relates to aggregated uncertainty in mercury fish research models, science, and biomonitoring. I use models, environmental intelligence networks and simulations of the effects of a changing climate on methylmercury in marine and freshwater fish to examine how climate change and the convention itself may create further uncertainties for policymakers to consider. Lastly, I will also present an environmental intelligence framework for fish mercury bioaccumulation models and biomonitoring in support of the evaluation of the effectiveness of the Minamata Convention on Mercury.

  2. Evaluation of a Method Using Three Genomic Guided Escherichia coli Markers for Phylogenetic Typing of E. coli Isolates of Various Genetic Backgrounds

    PubMed Central

    Hamamoto, Kouta; Ueda, Shuhei; Yamamoto, Yoshimasa

    2015-01-01

    Genotyping and characterization of bacterial isolates are essential steps in the identification and control of antibiotic-resistant bacterial infections. Recently, one novel genotyping method using three genomic guided Escherichia coli markers (GIG-EM), dinG, tonB, and dipeptide permease (DPP), was reported. Because GIG-EM has not been fully evaluated using clinical isolates, we assessed this typing method with 72 E. coli collection of reference (ECOR) environmental E. coli reference strains and 63 E. coli isolates of various genetic backgrounds. In this study, we designated 768 bp of dinG, 745 bp of tonB, and 655 bp of DPP target sequences for use in the typing method. Concatenations of the processed marker sequences were used to draw GIG-EM phylogenetic trees. E. coli isolates with identical sequence types as identified by the conventional multilocus sequence typing (MLST) method were localized to the same branch of the GIG-EM phylogenetic tree. Sixteen clinical E. coli isolates were utilized as test isolates without prior characterization by conventional MLST and phylogenetic grouping before GIG-EM typing. Of these, 14 clinical isolates were assigned to a branch including only isolates of a pandemic clone, E. coli B2-ST131-O25b, and these results were confirmed by conventional typing methods. Our results suggested that the GIG-EM typing method and its application to phylogenetic trees might be useful tools for the molecular characterization and determination of the genetic relationships among E. coli isolates. PMID:25809972

  3. Evaluation of a Method Using Three Genomic Guided Escherichia coli Markers for Phylogenetic Typing of E. coli Isolates of Various Genetic Backgrounds.

    PubMed

    Hamamoto, Kouta; Ueda, Shuhei; Yamamoto, Yoshimasa; Hirai, Itaru

    2015-06-01

    Genotyping and characterization of bacterial isolates are essential steps in the identification and control of antibiotic-resistant bacterial infections. Recently, one novel genotyping method using three genomic guided Escherichia coli markers (GIG-EM), dinG, tonB, and dipeptide permease (DPP), was reported. Because GIG-EM has not been fully evaluated using clinical isolates, we assessed this typing method with 72 E. coli collection of reference (ECOR) environmental E. coli reference strains and 63 E. coli isolates of various genetic backgrounds. In this study, we designated 768 bp of dinG, 745 bp of tonB, and 655 bp of DPP target sequences for use in the typing method. Concatenations of the processed marker sequences were used to draw GIG-EM phylogenetic trees. E. coli isolates with identical sequence types as identified by the conventional multilocus sequence typing (MLST) method were localized to the same branch of the GIG-EM phylogenetic tree. Sixteen clinical E. coli isolates were utilized as test isolates without prior characterization by conventional MLST and phylogenetic grouping before GIG-EM typing. Of these, 14 clinical isolates were assigned to a branch including only isolates of a pandemic clone, E. coli B2-ST131-O25b, and these results were confirmed by conventional typing methods. Our results suggested that the GIG-EM typing method and its application to phylogenetic trees might be useful tools for the molecular characterization and determination of the genetic relationships among E. coli isolates. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  4. Energy-efficient ovens for unpolluted balady bread

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gadalla, M.A.; Mansour, M.S.; Mahdy, E.

    A new bread oven has been developed, tested and presented in this work for local balady bread. The design has the advantage of being efficient and producing unpolluted bread. An extensive study of the conventional and available designs has been carried out in order to help developing the new design. Evaluation of the conventional design is based on numerous tests and measurements. A computer code utilizing the indirect method has been developed to evaluate the thermal performance of the tested ovens. The present design achieves higher thermal efficiency of about 50% than the conventional ones. In addition, its capital costmore » is much cheaper than other imported designs. Thus, the present design achieves higher efficiency, pollutant free products and less cost. Moreover, it may be modified for different types of bread baking systems.« less

  5. Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique.

    PubMed

    Kim, Jae-Hong; Kim, Ki-Baek; Kim, Woong-Chul; Kim, Ji-Hwan; Kim, Hae-Young

    2014-03-01

    This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP technique with an oral scanner. Six linear measurements were evaluated in terms of x, y, and z-axes using a non-contact white light scanner. Accuracy was assessed using mean differences between two measurements, and precision was examined using four quantitative methods and the Bland-Altman graphical method. Repeatability was evaluated in terms of intra-examiner variability, and reproducibility was assessed in terms of inter-examiner and inter-method variability. The mean difference between plaster models and PUT models ranged from 0.07 mm to 0.33 mm. Relative measurement errors ranged from 2.2% to 7.6% and intraclass correlation coefficients ranged from 0.93 to 0.96, when comparing plaster models and PUT models. The Bland-Altman plot showed good agreement. The accuracy and precision of PUT dental models for evaluating the performance of oral scanner and subtractive RP technology was acceptable. Because of the recent improvements in block material and computerized numeric control milling machines, the subtractive RP method may be a good choice for dental arch models.

  6. High-Accuracy Ultrasound Contrast Agent Detection Method for Diagnostic Ultrasound Imaging Systems.

    PubMed

    Ito, Koichi; Noro, Kazumasa; Yanagisawa, Yukari; Sakamoto, Maya; Mori, Shiro; Shiga, Kiyoto; Kodama, Tetsuya; Aoki, Takafumi

    2015-12-01

    An accurate method for detecting contrast agents using diagnostic ultrasound imaging systems is proposed. Contrast agents, such as microbubbles, passing through a blood vessel during ultrasound imaging are detected as blinking signals in the temporal axis, because their intensity value is constantly in motion. Ultrasound contrast agents are detected by evaluating the intensity variation of a pixel in the temporal axis. Conventional methods are based on simple subtraction of ultrasound images to detect ultrasound contrast agents. Even if the subject moves only slightly, a conventional detection method will introduce significant error. In contrast, the proposed technique employs spatiotemporal analysis of the pixel intensity variation over several frames. Experiments visualizing blood vessels in the mouse tail illustrated that the proposed method performs efficiently compared with conventional approaches. We also report that the new technique is useful for observing temporal changes in microvessel density in subiliac lymph nodes containing tumors. The results are compared with those of contrast-enhanced computed tomography. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  7. A methylene blue-assisted technique for harvesting lymph nodes after radical surgery for gastric cancer: a prospective, randomized, controlled study.

    PubMed

    Aoyama, Toru; Fujikawa, Hirohito; Cho, Haruhiko; Ogata, Takashi; Shirai, Junya; Hayashi, Tsutomu; Rino, Yasushi; Masuda, Munetaka; Oba, Mari S; Morita, Satoshi; Yoshikawa, Takaki

    2015-02-01

    Harvesting lymph nodes (LNs) after gastrectomy is essential for accurate staging. This trial evaluated the efficiency and quality of a conventional method and a methylene blue-assisted method in a randomized manner. The key eligibility criteria were as follows: (i) histologically proven adenocarcinoma of the stomach; (ii) clinical stage I-III; (iii) R0 resection planned by gastrectomy with D1+ or D2 lymphadenectomy. The primary endpoint was the ratio of the pathologic number of harvested LNs per time (minutes) as an efficacy measure. The secondary endpoint was the number of harvested LNs, as a quality measure. Between August 2012 and December 2012, 60 patients were assigned to undergo treatment using the conventional method (n=29) and the methylene blue dye method (n=31). The baseline demographics were mostly well balanced between the 2 groups. The number of harvested LNs (mean±SD) was 33.6±11.9 in the conventional arm and 43.4±13.9 in the methylene blue arm (P=0.005). The ratio of the number of the harvested LNs per time was 1.12±0.46 LNs/min in the conventional arm and 1.49±0.59 LNs/min in the methylene blue arm (P=0.010). In the subgroup analyses, the quality and efficacy were both superior for the methylene blue dye method compared with the conventional method. The methylene blue technique is recommended for harvesting LNs during gastric cancer surgery on the basis of both the quality and efficacy.

  8. A Methylene Blue–assisted Technique for Harvesting Lymph Nodes After Radical Surgery for Gastric Cancer

    PubMed Central

    Aoyama, Toru; Fujikawa, Hirohito; Cho, Haruhiko; Ogata, Takashi; Shirai, Junya; Hayashi, Tsutomu; Rino, Yasushi; Masuda, Munetaka; Oba, Mari S.; Morita, Satoshi

    2015-01-01

    Harvesting lymph nodes (LNs) after gastrectomy is essential for accurate staging. This trial evaluated the efficiency and quality of a conventional method and a methylene blue–assisted method in a randomized manner. The key eligibility criteria were as follows: (i) histologically proven adenocarcinoma of the stomach; (ii) clinical stage I-III; (iii) R0 resection planned by gastrectomy with D1+ or D2 lymphadenectomy. The primary endpoint was the ratio of the pathologic number of harvested LNs per time (minutes) as an efficacy measure. The secondary endpoint was the number of harvested LNs, as a quality measure. Between August 2012 and December 2012, 60 patients were assigned to undergo treatment using the conventional method (n=29) and the methylene blue dye method (n=31). The baseline demographics were mostly well balanced between the 2 groups. The number of harvested LNs (mean±SD) was 33.6±11.9 in the conventional arm and 43.4±13.9 in the methylene blue arm (P=0.005). The ratio of the number of the harvested LNs per time was 1.12±0.46 LNs/min in the conventional arm and 1.49±0.59 LNs/min in the methylene blue arm (P=0.010). In the subgroup analyses, the quality and efficacy were both superior for the methylene blue dye method compared with the conventional method. The methylene blue technique is recommended for harvesting LNs during gastric cancer surgery on the basis of both the quality and efficacy. PMID:25356528

  9. Nuclear moisture-density evaluation.

    DOT National Transportation Integrated Search

    1964-11-01

    This report constitutes the results of a series of calibration curves prepared by comparing the Troxler Nuclear Density - Moisture Gauge count ratios with conventional densities as obtained by the Soiltest Volumeter and the sand displacement methods....

  10. Proximal Gamma-Ray Spectroscopy to Predict Soil Properties Using Windows and Full-Spectrum Analysis Methods

    PubMed Central

    Mahmood, Hafiz Sultan; Hoogmoed, Willem B.; van Henten, Eldert J.

    2013-01-01

    Fine-scale spatial information on soil properties is needed to successfully implement precision agriculture. Proximal gamma-ray spectroscopy has recently emerged as a promising tool to collect fine-scale soil information. The objective of this study was to evaluate a proximal gamma-ray spectrometer to predict several soil properties using energy-windows and full-spectrum analysis methods in two differently managed sandy loam fields: conventional and organic. In the conventional field, both methods predicted clay, pH and total nitrogen with a good accuracy (R2 ≥ 0.56) in the top 0–15 cm soil depth, whereas in the organic field, only clay content was predicted with such accuracy. The highest prediction accuracy was found for total nitrogen (R2 = 0.75) in the conventional field in the energy-windows method. Predictions were better in the top 0–15 cm soil depths than in the 15–30 cm soil depths for individual and combined fields. This implies that gamma-ray spectroscopy can generally benefit soil characterisation for annual crops where the condition of the seedbed is important. Small differences in soil structure (conventional vs. organic) cannot be determined. As for the methodology, we conclude that the energy-windows method can establish relations between radionuclide data and soil properties as accurate as the full-spectrum analysis method. PMID:24287541

  11. Evaluation of bending rigidity behaviour of ultrasonic seaming on woven fabrics

    NASA Astrophysics Data System (ADS)

    Şevkan Macit, Ayşe; Tiber, Bahar

    2017-10-01

    In recent years ultrasonic seaming that is shown as an alternative method to conventional seaming has been investigated by many researchers. In our study, bending behaviour of this alternative method is examined by changing various parameters such as fabric type, seam type, roller type and seaming velocity. For this purpose fifteen types of sewn fabrics were tested according to bending rigidity test standard before and after washing processes and results were evaluated through SPSS statistical analyze programme. Consequently, bending length values of the ultrasonically sewn fabrics are found to be higher than the bending length values of conventionally sewn fabrics and the effects of seam type on bending length are seen statistically significant. Also it is observed that bending length values are in relationship with the rest of the parameters excluding roller type.

  12. Next Generation Flow for highly sensitive and standardized detection of minimal residual disease in multiple myeloma.

    PubMed

    Flores-Montero, J; Sanoja-Flores, L; Paiva, B; Puig, N; García-Sánchez, O; Böttcher, S; van der Velden, V H J; Pérez-Morán, J-J; Vidriales, M-B; García-Sanz, R; Jimenez, C; González, M; Martínez-López, J; Corral-Mateos, A; Grigore, G-E; Fluxá, R; Pontes, R; Caetano, J; Sedek, L; Del Cañizo, M-C; Bladé, J; Lahuerta, J-J; Aguilar, C; Bárez, A; García-Mateo, A; Labrador, J; Leoz, P; Aguilera-Sanz, C; San-Miguel, J; Mateos, M-V; Durie, B; van Dongen, J J M; Orfao, A

    2017-10-01

    Flow cytometry has become a highly valuable method to monitor minimal residual disease (MRD) and evaluate the depth of complete response (CR) in bone marrow (BM) of multiple myeloma (MM) after therapy. However, current flow-MRD has lower sensitivity than molecular methods and lacks standardization. Here we report on a novel next generation flow (NGF) approach for highly sensitive and standardized MRD detection in MM. An optimized 2-tube 8-color antibody panel was constructed in five cycles of design-evaluation-redesign. In addition, a bulk-lysis procedure was established for acquisition of ⩾10 7 cells/sample, and novel software tools were constructed for automatic plasma cell gating. Multicenter evaluation of 110 follow-up BM from MM patients in very good partial response (VGPR) or CR showed a higher sensitivity for NGF-MRD vs conventional 8-color flow-MRD -MRD-positive rate of 47 vs 34% (P=0.003)-. Thus, 25% of patients classified as MRD-negative by conventional 8-color flow were MRD-positive by NGF, translating into a significantly longer progression-free survival for MRD-negative vs MRD-positive CR patients by NGF (75% progression-free survival not reached vs 7 months; P=0.02). This study establishes EuroFlow-based NGF as a highly sensitive, fully standardized approach for MRD detection in MM which overcomes the major limitations of conventional flow-MRD methods and is ready for implementation in routine diagnostics.

  13. Nonuniform fast Fourier transform method for numerical diffraction simulation on tilted planes.

    PubMed

    Xiao, Yu; Tang, Xiahui; Qin, Yingxiong; Peng, Hao; Wang, Wei; Zhong, Lijing

    2016-10-01

    The method, based on the rotation of the angular spectrum in the frequency domain, is generally used for the diffraction simulation between the tilted planes. Due to the rotation of the angular spectrum, the interval between the sampling points in the Fourier domain is not even. For the conventional fast Fourier transform (FFT)-based methods, a spectrum interpolation is needed to get the approximate sampling value on the equidistant sampling points. However, due to the numerical error caused by the spectrum interpolation, the calculation accuracy degrades very quickly as the rotation angle increases. Here, the diffraction propagation between the tilted planes is transformed into a problem about the discrete Fourier transform on the uneven sampling points, which can be evaluated effectively and precisely through the nonuniform fast Fourier transform method (NUFFT). The most important advantage of this method is that the conventional spectrum interpolation is avoided and the high calculation accuracy can be guaranteed for different rotation angles, even when the rotation angle is close to π/2. Also, its calculation efficiency is comparable with that of the conventional FFT-based methods. Numerical examples as well as a discussion about the calculation accuracy and the sampling method are presented.

  14. Pain score of patients undergoing single spot, short pulse laser versus conventional laser for diabetic retinopathy.

    PubMed

    Mirshahi, Ahmad; Lashay, Alireza; Roozbahani, Mehdi; Fard, Masoud Aghsaei; Molaie, Saber; Mireshghi, Meysam; Zaferani, Mohamad Mehdi

    2013-04-01

    To compare pain score of single spot short duration time (20 milliseconds) panretinal photocoagulation (PRP) with conventional (100 milliseconds) PRP in diabetic retinopathy. Sixty-six eyes from 33 patients with symmetrical severe non-proliferative diabetic retinopathy (non-PDR) or proliferative diabetic retinopathy (PDR) were enrolled in this prospective randomized controlled trial. One eye of each patient was randomized to undergo conventional and the other eye to undergo short time PRP. Spot size of 200 μm was used in both laser types, and energy was adjusted to achieve moderate burn on the retina. Patients were asked to mark the level of pain felt during the PRP session for each eye on the visual analog scale (VAS) and were examined at 1 week, and at 1, 2, 4 and 6 months. Sixteen women and 17 men with mean age 58.9 ± 7.8 years were evaluated. The conventional method required a mean power of 273 ± 107 mW, whereas the short duration method needed 721 ± 406 mW (P = 0.001). An average of 1,218 ± 441 spots were delivered with the conventional method and an average of 2,125 ± 503 spots were required with the short duration method (P = 0.001). Average pain score was 7.5 ± 1.14 in conventional group and 1.75 ± 0.87 in the short duration group (P = 0.001). At 1 week, 1 month, and 4 months following PRP, the mean changes of central macular thickness (CMT) from baseline in the conventional group remained 29.2 μm (P = 0.008), 40.0 μm (P = 0.001), and 40.2 μm (P = 0.007) greater than the changes in CMT for short time group. Patient acceptance of short time single spot PRP was high, and well-tolerated in a single session by all patients. Moreover, this method is significantly less painful than but just as effective as conventional laser during 6 months of follow-up. The CMT change was more following conventional laser than short time laser.

  15. Bayesian dose-response analysis for epidemiological studies with complex uncertainty in dose estimation.

    PubMed

    Kwon, Deukwoo; Hoffman, F Owen; Moroz, Brian E; Simon, Steven L

    2016-02-10

    Most conventional risk analysis methods rely on a single best estimate of exposure per person, which does not allow for adjustment for exposure-related uncertainty. Here, we propose a Bayesian model averaging method to properly quantify the relationship between radiation dose and disease outcomes by accounting for shared and unshared uncertainty in estimated dose. Our Bayesian risk analysis method utilizes multiple realizations of sets (vectors) of doses generated by a two-dimensional Monte Carlo simulation method that properly separates shared and unshared errors in dose estimation. The exposure model used in this work is taken from a study of the risk of thyroid nodules among a cohort of 2376 subjects who were exposed to fallout from nuclear testing in Kazakhstan. We assessed the performance of our method through an extensive series of simulations and comparisons against conventional regression risk analysis methods. When the estimated doses contain relatively small amounts of uncertainty, the Bayesian method using multiple a priori plausible draws of dose vectors gave similar results to the conventional regression-based methods of dose-response analysis. However, when large and complex mixtures of shared and unshared uncertainties are present, the Bayesian method using multiple dose vectors had significantly lower relative bias than conventional regression-based risk analysis methods and better coverage, that is, a markedly increased capability to include the true risk coefficient within the 95% credible interval of the Bayesian-based risk estimate. An evaluation of the dose-response using our method is presented for an epidemiological study of thyroid disease following radiation exposure. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Diagnostic Tools for Performance Evaluation of Innovative In-Situ Remediation Technologies at Chlorinated Solvent-Contaminated Sites

    DTIC Science & Technology

    2011-07-01

    to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT...these innovative methods with conventional diagnostic tools that are currently used for assessing bioremediation performance. 132 Rula Deeb (510) 596...conventional diagnostic tools that are currently used for assessing bioremediation performance. DEMONSTRATION RESULTS 3-D multi-level systems

  17. The Use of an Intra-Articular Depth Guide in the Measurement of Partial Thickness Rotator Cuff Tears

    PubMed Central

    Carroll, Michael J.; More, Kristie D.; Sohmer, Stephen; Nelson, Atiba A.; Sciore, Paul; Boorman, Richard; Hollinshead, Robert; Lo, Ian K. Y.

    2013-01-01

    Purpose. The purpose of this study was to compare the accuracy of the conventional method for determining the percentage of partial thickness rotator cuff tears to a method using an intra-articular depth guide. The clinical utility of the intra-articular depth guide was also examined. Methods. Partial rotator cuff tears were created in cadaveric shoulders. Exposed footprint, total tendon thickness, and percentage of tendon thickness torn were determined using both techniques. The results from the conventional and intra-articular depth guide methods were correlated with the true anatomic measurements. Thirty-two patients were evaluated in the clinical study. Results. Estimates of total tendon thickness (r = 0.41, P = 0.31) or percentage of thickness tears (r = 0.67, P = 0.07) using the conventional method did not correlate well with true tendon thickness. Using the intra-articular depth guide, estimates of exposed footprint (r = 0.92, P = 0.001), total tendon thickness (r = 0.96, P = 0.0001), and percentage of tendon thickness torn (r = 0.88, P = 0.004) correlated with true anatomic measurements. Seven of 32 patients had their treatment plan altered based on the measurements made by the intra-articular depth guide. Conclusions. The intra-articular depth guide appeared to better correlate with true anatomic measurements. It may be useful during the evaluation and development of treatment plans for partial thickness articular surface rotator cuff tears. PMID:23533789

  18. Imaging technique for the complete edentulous patient treated conventionally or with mini implant overdenture

    PubMed Central

    Meleşcanu Imre, M; Preoteasa, E; Țâncu, AM; Preoteasa, CT

    2013-01-01

    Rationale. The imaging methods are more and more used in the clinical process of modern dentistry. Once the implant based treatment alternatives are nowadays seen as being the standard of care in edentulous patients, these techniques must be integrated in the complete denture treatment. Aim. The study presents some evaluation techniques for the edentulous patient treated by conventional dentures or mini dental implants (mini SKY Bredent) overdentures, using the profile teleradiography. These offer data useful for an optimal positioning of the artificial teeth and the mini dental implants, favoring to obtain an esthetic and functional treatment outcome. We proposed also a method to conceive a simple surgical guide that allows the prosthetically driven implants placement. Material and method. Clinical case reports were made, highlighting the importance of cephalometric evaluation on lateral teleradiographs in complete edentulous patients. A clinical case that gradually reports the surgical guide preparation (Bredent silicon radio opaque), in order to place the mini dental implants in the best prosthetic and anatomic conditions, was presented. Conclusions. The profile teleradiograph is a useful tool for the practitioner. It allows establishing the optimal site for implant placement, in a good relation with the overdenture. The conventional denture can be easily and relatively costless transformed in a surgical guide used during implant placement. PMID:23599828

  19. Clinical effect of individualized parenteral nutrition vs conventional method in patients undergoing autologous hematopoietic SCT.

    PubMed

    Tavakoli-Ardakani, M; Neman, B; Mehdizadeh, M; Hajifathali, A; Salamzadeh, J; Tabarraee, M

    2013-07-01

    Malnutrition in patients undergoing hematopoietic SCT is known as a risk factor for adverse effects and is directly or indirectly responsible for excess mortality and morbidity. We designed the present study to evaluate the effects of individualized parenteral nutrition (PN) and compare the present method to the conventional PN. Individualized PN based on the Harris-Benedict equation was administered to 30 patients after hematopoietic SCT and was compared with an age, gender and disease matched group of patients who underwent hematopoietic SCT with conventional PN. These two groups were compared on clinical, hematological, nutritional outcomes. Comparing duration of hospital stay (P value<0.0001), infection (P value = 0.01), time to platelet engraftment (P value = 0.02), units of packed cell transfusion (P value = 0.006) and decrease in body weight (P value = 0.004) showed significant differences between the two groups. In conclusion, the use of individualized PN seems more beneficial than conventional PN.

  20. Comparison of conventional and digital radiography for radiometric differentiation of dental cements.

    PubMed

    Baksi, B Güniz; Ermis, R Banu

    2007-10-01

    To test the efficacy of conventional radiometry with indirect digital image analysis in the assessment of the relative radiopacity of dental cements used as liners or bases compared to human enamel and dentin. Disks of 15 different dental cements, 5 mm in diameter and 2 mm thick, were exposed to radiation together with 2-mm-thick disks of enamel and dentin and an aluminum step wedge. Density was evaluated by digital transmission densitometry and with the histogram function of an image analysis program following digitization of the radiographs with a flatbed scanner. A higher number of dental cements were discriminated from both dentin and enamel with conventional radiographic densitometer. All the cements examined, except Ionoseal (Voco) and Ionobond (Voco), were more radiopaque than dentin. With both methods, Chelon-Silver (3M ESPE) had the highest radiopacity and glass-ionomer cements the lowest. Radiodensity of dental cements can be differentiated with a high probability with the conventional radiometric method.

  1. Comparison of embryo development between intracytoplasmic and Piezo-assisted sperm injection after treating mouse sperms by Ca2+ ionophore.

    PubMed

    Shahverdi, Abdolhossein; Movahedin, Mansoureh; Rezazadeh Valojerdi, Mojtaba; Kazemi Ashtiani, Saeid

    2007-10-01

    The purpose of this study was to evaluate the efficiency of intracytoplasmic sperm injection (ICSI) and Piezo-assisted sperm injection after pretreatment with calcium ionophore (CaI) on the mouse embryo development. In this study, the conventional ICSI and Piezo-ICSI procedures were used. The efficacy of the methods was examined after mouse matured oocytes were fertilized with or without CaI-treated sperms. Piezo-ICSI demonstrated significantly more favorable results, with a fertilization rate of 64% (conventional ICSI: 42%, P<0.001) and a cleavage rate of 73% (conventional ICSI: 58%, P<0.05). When the Piezo-ICSI procedure was performed with CaI-pretreated sperms, the cleavage rate significantly increased (92% vs. 73%, P<0.05). However, the fertilization rate did not change significantly (64% vs. 56%). The Piezo-ICSI accompanies with CaI-treated sperms is more efficient than the conventional ICSI method for fertilizing and thus obtaining more mouse embryos.

  2. Evaluating different planting stocks for oak regeneration on Hurricane Katrina disturbed lands

    Treesearch

    Damon B. Hollis; Andrew W. Ezell; Emily B. Schultz; John D. Hodges; Andrew B. Self; Derek K. Alkire

    2012-01-01

    Three oak planting stocks were evaluated to determine their influence on survival and initial growth. Planting stocks utilized included conventional containerized seedlings in 240 centimeter3 (cm3) containers, 1-0, bareroot seedlings, and Root Production Method (RPM™) seedlings in 11.4 liter (L) containers. Initial height, groundline diameter (...

  3. Using Oral Exams to Assess Communication Skills in Business Courses

    ERIC Educational Resources Information Center

    Burke-Smalley, Lisa A.

    2014-01-01

    Business, like many other fields in higher education, continues to rely largely on conventional testing methods for assessing student learning. In the current article, another evaluation approach--the oral exam--is examined as a means for building and evaluating the professional communication and oral dialogue skills needed and utilized by…

  4. Using Radar Charts with Qualitative Evaluation: Techniques to Assess Change in Blended Learning

    ERIC Educational Resources Information Center

    Kaczynski, Dan; Wood, Leigh; Harding, Ansie

    2008-01-01

    When university academics implement changes in learning, such as introducing blended learning, it is conventional practice to examine and evaluate the impact of the resulting curriculum reform. Judging the worth and impact of an educational development is a complex task involving subtle differences in learning. Qualitative methods to explore these…

  5. Molar cusp deformation evaluated by micro-CT and enamel crack formation to compare incremental and bulk-filling techniques.

    PubMed

    Oliveira, Laís Rani Sales; Braga, Stella Sueli Lourenço; Bicalho, Aline Arêdes; Ribeiro, Maria Tereza Hordones; Price, Richard Bengt; Soares, Carlos José

    2018-07-01

    To describe a method of measuring the molar cusp deformation using micro-computed tomography (micro-CT), the propagation of enamel cracks using transillumination, and the effects of hygroscopic expansion after incremental and bulk-filling resin composite restorations. Twenty human molars received standardized Class II mesio-occlusal-distal cavity preparations. They were restored with either a bulk-fill resin composite, X-tra fil (XTRA), or a conventional resin composite, Filtek Z100 (Z100). The resin composites were tested for post-gel shrinkage using a strain gauge method. Cusp deformation (CD) was evaluated using the images obtained using a micro-CT protocol and using a strain-gauge method. Enamel cracks were detected using transillumination. The post-gel shrinkage of Z100 was higher than XTRA (P < 0.001). The amount of cusp deformation produced using Z100 was higher compared to XTRA, irrespective of the measurement method used (P < 0.001). The thinner lingual cusp always had a higher CD than the buccal cusp, irrespective of the measurement method (P < 0.001). A positive correlation (r = 0.78) was found between cusp deformation measured by micro-CT or by the strain-gauge method. After hygroscopic expansion of the resin composite, the cusp displacement recovered around 85% (P < 0.001). After restoration, Z100 produced more cracks than XTRA (P = 0.012). Micro-CT was an effective method for evaluating the cusp deformation. Transillumination was effective for detecting enamel cracks. There were fewer negative effects of polymerization shrinkage in bulk-fill resin restorations using XTRA than for the conventional incremental filling technique using conventional composite resin Z100. Shrinkage and cusp deformation are directly related to the formation of enamel cracks. Cusp deformation and crack propagation may increase the risk of tooth fracture. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Preparation and evaluation of cyclosporin A-containing proliposomes: a comparison of the supercritical antisolvent process with the conventional film method

    PubMed Central

    Karn, Pankaj Ranjan; Jin, Su-Eon; Lee, Benjamin Joon; Sun, Bo Kyung; Kim, Min-Soo; Sung, Jong-Hyuk; Hwang, Sung-Joo

    2014-01-01

    Objectives The objectives of this study were to prepare cyclosporin A (CsA)-containing proliposomes using the supercritical antisolvent (SAS) process and the conventional thin film method for the comparative study of proliposomal formulations and to evaluate the physicochemical properties of these proliposomes. Methods CsA-containing proliposomes were prepared by the SAS process and the conventional film method, composed of natural and synthetic phospholipids. We investigated particle size, polydispersity index, and zeta potential of CsA-containing proliposomes. In addition, both production yield and entrapment efficiency of CsA in different proliposomes were analyzed. Physicochemical properties of CsA-containing proliposomes were also evaluated, using differential scanning calorimetry and X-ray diffraction. The morphology and size of CsA-containing proliposomes were confirmed, using scanning electron microscopy. We checked the in vitro release of CsA from CsA-containing proliposomes prepared by different preparation methods, comparing them with Restasis® as a positive control and the stability of SAS-mediated proliposomes was also studied. Results CsA-containing proliposomes formed by the SAS process had a relatively smaller particle size, with a narrow size distribution and spherical particles compared with those of conventionally prepared proliposomes. The yield and entrapment efficiency of CsA in all proliposomes varied from 85% to 92% and from 86% to 89%, respectively. Differential scanning calorimetry and X-ray diffraction studies revealed that the anhydrous lactose powder used in this formulation retained its crystalline form and that CsA was present in an amorphous form. Proliposome powders were rapidly converted to liposomes on contact with water. The in vitro release study of proliposomal formulations demonstrated a similar pattern to Restasis®. The SAS-mediated CsA-containing proliposomes were stable on storage, with no significant changes in particle size, polydispersity index, and entrapment efficiency. Conclusion These results show promising features of CsA-containing proliposomal formulations, using the SAS process for the large-scale industrial application. PMID:25395846

  7. Agreement between gastrointestinal panel testing and standard microbiology methods for detecting pathogens in suspected infectious gastroenteritis: Test evaluation and meta-analysis in the absence of a reference standard.

    PubMed

    Freeman, Karoline; Tsertsvadze, Alexander; Taylor-Phillips, Sian; McCarthy, Noel; Mistry, Hema; Manuel, Rohini; Mason, James

    2017-01-01

    Multiplex gastrointestinal pathogen panel (GPP) tests simultaneously identify bacterial, viral and parasitic pathogens from the stool samples of patients with suspected infectious gastroenteritis presenting in hospital or the community. We undertook a systematic review to compare the accuracy of GPP tests with standard microbiology techniques. Searches in Medline, Embase, Web of Science and the Cochrane library were undertaken from inception to January 2016. Eligible studies compared GPP tests with standard microbiology techniques in patients with suspected gastroenteritis. Quality assessment of included studies used tailored QUADAS-2. In the absence of a reference standard we analysed test performance taking GPP tests and standard microbiology techniques in turn as the benchmark test, using random effects meta-analysis of proportions. No study provided an adequate reference standard with which to compare the test accuracy of GPP and conventional tests. Ten studies informed a meta-analysis of positive and negative agreement. Positive agreement across all pathogens was 0.93 (95% CI 0.90 to 0.96) when conventional methods were the benchmark and 0.68 (95% CI: 0.58 to 0.77) when GPP provided the benchmark. Negative agreement was high in both instances due to the high proportion of negative cases. GPP testing produced a greater number of pathogen-positive findings than conventional testing. It is unclear whether these additional 'positives' are clinically important. GPP testing has the potential to simplify testing and accelerate reporting when compared to conventional microbiology methods. However the impact of GPP testing upon the management, treatment and outcome of patients is poorly understood and further studies are needed to evaluate the health economic impact of GPP testing compared with standard methods. The review protocol is registered with PROSPERO as CRD42016033320.

  8. Usefulness of diffusion-weighted MR imaging for differentiating between benign and malignant superficial soft tissue tumours and tumour-like lesions

    PubMed Central

    Jeon, Ji Young; Lee, Min Hee; Lee, Sang Hoon; Shin, Myung Jin

    2016-01-01

    Objective: To evaluate the usefulness of adding diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) mapping to conventional 3.0-T MRI to differentiate between benign and malignant superficial soft-tissue masses (SSTMs). Methods: The institutional review board approved this study and informed consent was waived. The authors retrospectively analyzed conventional MR images including diffusion-weighted images (b-values: 0, 400, 800 s mm−2) in 60 histologically proven SSTMs (35 benign and 25 malignant) excluding lipomas. Two radiologists independently evaluated the conventional MRI alone and again with the additional DWI for the evaluation of malignant masses. The mean ADC values measured within an entire mass and the contrast-enhancing solid portion were used for quantitative analysis. Diagnostic performances were compared using receiver-operating characteristic analysis. Results: For an inexperienced reader, using only conventional MRI, the sensitivity, specificity and accuracy were 84%, 80% and 81.6%, respectively. When combining conventional MRI and DWI, the sensitivity, specificity and accuracy were 96%, 85.7% and 90%, respectively. Additional DWI influenced the improvement of the rate of correct diagnosis by 8.3% (5/60). For an experienced reader, additional DWI revealed the same accuracy of 86.7% without added value on the correct diagnosis. The group mean ADCs of malignant SSTMs were significantly lower than that of benign SSTMs (p < 0.001). The best diagnostic performance with respect to differentiation of SSTMs could be obtained when conventional MRI was assessed in combination with DWI. Conclusion: Adding qualitative and quantitative DWI to conventional MRI can improve the diagnostic performance for the differentiation between benign and malignant SSTMs. Advances in knowledge: Because the imaging characteristics of many malignant superficial soft-tissue lesions overlap with those of benign ones, inadequate surgical resection due to misinterpretation of MRI often occurs. Adding DWI to conventional MRI yields greater diagnostic performances [area under the receiver-operating characteristic curve (AUC), 0.83–0.99] than does the use of conventional MRI alone (AUC, 0.71–0.93) in the evaluation of malignant superficial masses by inexperienced readers. PMID:26892266

  9. Gram staining apparatus for space station applications

    NASA Technical Reports Server (NTRS)

    Molina, T. C.; Brown, H. D.; Irbe, R. M.; Pierson, D. L.

    1990-01-01

    A self-contained, portable Gram staining apparatus (GSA) has been developed for use in the microgravity environment on board the Space Station Freedom. Accuracy and reproducibility of this apparatus compared with the conventional Gram staining method were evaluated by using gram-negative and gram-positive controls and different species of bacteria grown in pure cultures. A subsequent study was designed to assess the performance of the GSA with actual specimens. A set of 60 human and environmental specimens was evaluated with the GSA and the conventional Gram staining procedure. Data obtained from these studies indicated that the GSA will provide the Gram staining capability needed for the microgravity environment of space.

  10. Effect of mirror therapy on upper extremity motor function in stroke patients: a randomized controlled trial.

    PubMed

    Gurbuz, Nigar; Afsar, Sevgi Ikbali; Ayaş, Sehri; Cosar, Sacide Nur Saracgil

    2016-09-01

    [Purpose] This study aimed to evaluate the effectiveness of mirror therapy combined with a conventional rehabilitation program on upper extremity motor and functional recovery in stroke patients. [Subjects and Methods] Thirty-one hemiplegic patients were included. The patients were randomly assigned to a mirror (n=16) or conventional group (n=15). The patients in both groups underwent conventional therapy for 4 weeks (60-120 minutes/day, 5 days/week). The mirror group received mirror therapy, consisting of periodic flexion and extension movements of the wrist and fingers on the non-paralyzed side. The patients in the conventional group performed the same exercises against the non-reflecting face of the mirror. The patients were evaluated at the beginning and end of the treatment by a blinded assessor using the Brunnstrom stage, Fugl-Meyer Assessment (FMA) upper extremity score, and the Functional Independence Measure (FIM) self-care score. [Results] There was an improvement in Brunnstrom stage and the FIM self-care score in both groups, but the post-treatment FMA score was significantly higher in the mirror therapy group than in the conventional treatment group. [Conclusion] Mirror therapy in addition to a conventional rehabilitation program was found to provide additional benefit in motor recovery of the upper extremity in stroke patients.

  11. Effect of mirror therapy on upper extremity motor function in stroke patients: a randomized controlled trial

    PubMed Central

    Gurbuz, Nigar; Afsar, Sevgi Ikbali; Ayaş, Sehri; Cosar, Sacide Nur Saracgil

    2016-01-01

    [Purpose] This study aimed to evaluate the effectiveness of mirror therapy combined with a conventional rehabilitation program on upper extremity motor and functional recovery in stroke patients. [Subjects and Methods] Thirty-one hemiplegic patients were included. The patients were randomly assigned to a mirror (n=16) or conventional group (n=15). The patients in both groups underwent conventional therapy for 4 weeks (60–120 minutes/day, 5 days/week). The mirror group received mirror therapy, consisting of periodic flexion and extension movements of the wrist and fingers on the non-paralyzed side. The patients in the conventional group performed the same exercises against the non-reflecting face of the mirror. The patients were evaluated at the beginning and end of the treatment by a blinded assessor using the Brunnstrom stage, Fugl-Meyer Assessment (FMA) upper extremity score, and the Functional Independence Measure (FIM) self-care score. [Results] There was an improvement in Brunnstrom stage and the FIM self-care score in both groups, but the post-treatment FMA score was significantly higher in the mirror therapy group than in the conventional treatment group. [Conclusion] Mirror therapy in addition to a conventional rehabilitation program was found to provide additional benefit in motor recovery of the upper extremity in stroke patients. PMID:27799679

  12. Comparison of conventional and synchrotron-radiation-based microtomography of bone around dental implants

    NASA Astrophysics Data System (ADS)

    Cattaneo, Paolo M.; Dalstra, Michel; Beckmann, Felix; Donath, Tilman; Melsen, Birte

    2004-10-01

    This study explores the application of conventional micro tomography (μCT) and synchrotron radiation (SR) based μCT to evaluate the bone around titanium dental implants. The SR experiment was performed at beamline W2 of HASYLAB at DESY using a monochromatic X-ray beam of 50 keV. The testing material consisted of undecalcified bone segments harvested from the upper jaw of a macaca fascicularis monkey each containing a titanium dental implant. The results from the two different techniques were qualitatively compared with conventional histological sections examined under light microscopy. The SR-based μCT produced images that, especially at the bone-implant interface, are less noisy and sharper than the ones obtained with conventional μCT. For the proper evaluation of the implant-bone interface, only the SR-based μCT technique is able to display the areas of bony contact and visualize the true 3D structure of bone around dental implants correctly. This investigation shows that both conventional and SR-based μCT scanning techniques are non-destructive methods, which provide detailed images of bone. However with SR-based μCT it is possible to obtain an improved image quality of the bone surrounding dental implants, which display a level of detail comparable to histological sections. Therefore, SR-based μCT scanning could represent a valid, unbiased three-dimensional alternative to evaluate osseointegration of dental implants

  13. Impact of virtual microscopy with conventional microscopy on student learning in dental histology.

    PubMed

    Hande, Alka Harish; Lohe, Vidya K; Chaudhary, Minal S; Gawande, Madhuri N; Patil, Swati K; Zade, Prajakta R

    2017-01-01

    In dental histology, the assimilation of histological features of different dental hard and soft tissues is done by conventional microscopy. This traditional method of learning prevents the students from screening the entire slide and change of magnification. To address these drawbacks, modification in conventional microscopy has evolved and become motivation for changing the learning tool. Virtual microscopy is the technique in which there is complete digitization of the microscopic glass slide, which can be analyzed on a computer. This research is designed to evaluate the effectiveness of virtual microscopy with conventional microscopy on student learning in dental histology. A cohort of 105 students were included and randomized into three groups: A, B, and C. Group A students studied the microscopic features of oral histologic lesions by conventional microscopy, Group B by virtual microscopy, and Group C by both conventional and virtual microscopy. The students' understanding of the subject was evaluated by a prepared questionnaire. The effectiveness of the study designs on knowledge gains and satisfaction levels was assessed by statistical assessment of differences in mean test scores. The difference in score between Groups A, B, and C at pre- and post-test was highly significant. This enhanced understanding of the subject may be due to benefits of using virtual microscopy in teaching histology. The augmentation of conventional microscopy with virtual microscopy shows enhancement of the understanding of the subject as compared to the use of conventional microscopy and virtual microscopy alone.

  14. Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique

    PubMed Central

    Kim, Jae-Hong; Kim, Ki-Baek; Kim, Woong-Chul; Kim, Ji-Hwan

    2014-01-01

    Objective This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Methods Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP technique with an oral scanner. Six linear measurements were evaluated in terms of x, y, and z-axes using a non-contact white light scanner. Accuracy was assessed using mean differences between two measurements, and precision was examined using four quantitative methods and the Bland-Altman graphical method. Repeatability was evaluated in terms of intra-examiner variability, and reproducibility was assessed in terms of inter-examiner and inter-method variability. Results The mean difference between plaster models and PUT models ranged from 0.07 mm to 0.33 mm. Relative measurement errors ranged from 2.2% to 7.6% and intraclass correlation coefficients ranged from 0.93 to 0.96, when comparing plaster models and PUT models. The Bland-Altman plot showed good agreement. Conclusions The accuracy and precision of PUT dental models for evaluating the performance of oral scanner and subtractive RP technology was acceptable. Because of the recent improvements in block material and computerized numeric control milling machines, the subtractive RP method may be a good choice for dental arch models. PMID:24696823

  15. Use of two conventional staining methods to assess the acrosomal status of stallion spermatozoa.

    PubMed

    Runcan, E E; Pozor, M A; Zambrano, G L; Benson, S; Macpherson, M L

    2014-07-01

    The acrosome is a highly specialised region of the spermatozoon that is essential for fertilisation. Defects or dysfunction of this structure have been associated with fertility problems in man and various domestic species including stallions. Current methods of evaluating the acrosome of stallion spermatozoa are time consuming and require specialised equipment, which is cost prohibitive to the average practitioner. To evaluate 2 conventional stains (Dip Quick and Spermac) and determine their usefulness in assessing acrosome integrity in stallions as compared with specific acrosomal labelling with a fluorescein-conjugated lectin - a method that has been validated for acrosome status evaluation in stallions. In vivo experimental design. Semen from 6 mature Miniature horse stallions of known fertility was collected on 5 separate occasions. To increase the number of reacted acrosomes, portions of each ejaculate were incubated with the calcium ionophore, A23187. Ejaculates were divided and semen samples were processed according to recommendations for fluorescein-conjugated peanut lectin, Pisum sativum agglutin, Dip Quick, and Spermac staining methods. Slides were evaluated independently by 2 separate investigators. Spermatozoa were classified as having intact, reacting, reacted or defective acrosomes. All parameters obtained by both investigators, using all 3 staining methods were highly correlated (P<0.001). There was no statistical difference (P>0.05) between investigators or staining method for the percentages of intact or reacted acrosomes. However, there was a significant difference between investigators and staining methods for determining reacting acrosome percentages (P<0.05). Dip Quick and Spermac stains are useful for determining intact vs. reacted acrosomes for stallion spermatozoa. © 2013 EVJ Ltd.

  16. System Vaccinology for the Evaluation of Influenza Vaccine Safety by Multiplex Gene Detection of Novel Biomarkers in a Preclinical Study and Batch Release Test

    PubMed Central

    Mizukami, Takuo; Momose, Haruka; Kuramitsu, Madoka; Takizawa, Kazuya; Araki, Kumiko; Furuhata, Keiko; Ishii, Ken J.; Hamaguchi, Isao; Yamaguchi, Kazunari

    2014-01-01

    Vaccines are beneficial and universal tools to prevent infectious disease. Thus, safety of vaccines is strictly evaluated in the preclinical phase of trials and every vaccine batch must be tested by the National Control Laboratories according to the guidelines published by each country. Despite many vaccine production platforms and methods, animal testing for safety evaluation is unchanged thus far. We recently developed a systems biological approach to vaccine safety evaluation where identification of specific biomarkers in a rat pre-clinical study evaluated the safety of vaccines for pandemic H5N1 influenza including Irf7, Lgals9, Lgalsbp3, Cxcl11, Timp1, Tap2, Psmb9, Psme1, Tapbp, C2, Csf1, Mx2, Zbp1, Ifrd1, Trafd1, Cxcl9, β2m, Npc1, Ngfr and Ifi47. The current study evaluated whether these 20 biomarkers could evaluate the safety, batch-to-batch and manufacturer-to-manufacturer consistency of seasonal trivalent influenza vaccine using a multiplex gene detection system. When we evaluated the influenza HA vaccine (HAv) from four different manufactures, the biomarker analysis correlated to findings from conventional animal use tests, such as abnormal toxicity test. In addition, sensitivity of toxicity detection and differences in HAvs were higher and more accurate than with conventional methods. Despite a slight decrease in body weight caused by HAv from manufacturer B that was not statistically significant, our results suggest that HAv from manufacturer B is significantly different than the other HAvs tested with regard to Lgals3bp, Tapbp, Lgals9, Irf7 and C2 gene expression in rat lungs. Using the biomarkers confirmed in this study, we predicted batch-to-batch consistency and safety of influenza vaccines within 2 days compared with the conventional safety test, which takes longer. These biomarkers will facilitate the future development of new influenza vaccines and provide an opportunity to develop in vitro methods of evaluating batch-to-batch consistency and vaccine safety as an alternative to animal testing. PMID:25010690

  17. Retrieval of phase-derivative discontinuities in digital speckle pattern interferometry fringes using the Wigner-Ville distribution

    NASA Astrophysics Data System (ADS)

    Federico, Alejandro; Kaufmann, Guillermo H.

    2004-08-01

    We evaluate the application of the Wigner-Ville distribution (WVD) to measure phase gradient maps in digital speckle pattern interferometry (DSPI), when the generated correlation fringes present phase discontinuities. The performance of the WVD method is evaluated using computer-simulated fringes. The influence of the filtering process to smooth DSPI fringes and additional drawbacks that emerge when this method is applied are discussed. A comparison with the conventional method based on the continuous wavelet transform in the stationary phase approximation is also presented.

  18. An investigation of density measurement method for yarn-dyed woven fabrics based on dual-side fusion technique

    NASA Astrophysics Data System (ADS)

    Zhang, Rui; Xin, Binjie

    2016-08-01

    Yarn density is always considered as the fundamental structural parameter used for the quality evaluation of woven fabrics. The conventional yarn density measurement method is based on one-side analysis. In this paper, a novel density measurement method is developed for yarn-dyed woven fabrics based on a dual-side fusion technique. Firstly, a lab-used dual-side imaging system is established to acquire both face-side and back-side images of woven fabric and the affine transform is used for the alignment and fusion of the dual-side images. Then, the color images of the woven fabrics are transferred from the RGB to the CIE-Lab color space, and the intensity information of the image extracted from the L component is used for texture fusion and analysis. Subsequently, three image fusion methods are developed and utilized to merge the dual-side images: the weighted average method, wavelet transform method and Laplacian pyramid blending method. The fusion efficacy of each method is evaluated by three evaluation indicators and the best of them is selected to do the reconstruction of the complete fabric texture. Finally, the yarn density of the fused image is measured based on the fast Fourier transform, and the yarn alignment image could be reconstructed using the inverse fast Fourier transform. Our experimental results show that the accuracy of density measurement by using the proposed method is close to 99.44% compared with the traditional method and the robustness of this new proposed method is better than that of conventional analysis methods.

  19. Comparison the Marginal and Internal Fit of Metal Copings Cast from Wax Patterns Fabricated by CAD/CAM and Conventional Wax up Techniques

    PubMed Central

    Vojdani, M; Torabi, K; Farjood, E; Khaledi, AAR

    2013-01-01

    Statement of Problem: Metal-ceramic crowns are most commonly used as the complete coverage restorations in clinical daily use. Disadvantages of conventional hand-made wax-patterns introduce some alternative ways by means of CAD/CAM technologies. Purpose: This study compares the marginal and internal fit of copings cast from CAD/CAM and conventional fabricated wax-patterns. Materials and Method: Twenty-four standardized brass dies were prepared and randomly divided into 2 groups according to the wax-patterns fabrication method (CAD/CAM technique and conventional method) (n=12). All the wax-patterns were fabricated in a standard fashion by means of contour, thickness and internal relief (M1-M12: representative of CAD/CAM group, C1-C12: representative of conventional group). CAD/CAM milling machine (Cori TEC 340i; imes-icore GmbH, Eiterfeld, Germany) was used to fabricate the CAD/CAM group wax-patterns. The copings cast from 24 wax-patterns were cemented to the corresponding dies. For all the coping-die assemblies cross-sectional technique was used to evaluate the marginal and internal fit at 15 points. The Student’s t- test was used for statistical analysis (α=0.05). Results: The overall mean (SD) for absolute marginal discrepancy (AMD) was 254.46 (25.10) um for CAD/CAM group and 88.08(10.67) um for conventional group (control). The overall mean of internal gap total (IGT) was 110.77(5.92) um for CAD/CAM group and 76.90 (10.17) um for conventional group. The Student’s t-test revealed significant differences between 2 groups. Marginal and internal gaps were found to be significantly higher at all measured areas in CAD/CAM group than conventional group (p< 0.001). Conclusion: Within limitations of this study, conventional method of wax-pattern fabrication produced copings with significantly better marginal and internal fit than CAD/CAM (machine-milled) technique. All the factors for 2 groups were standardized except wax pattern fabrication technique, therefore, only the conventional group results in copings with clinically acceptable margins of less than 120um. PMID:24724133

  20. Characterisation of flattening filter free (FFF) beam properties for initial beam set-up and routine QA, independent of flattened beams

    NASA Astrophysics Data System (ADS)

    Paynter, D.; Weston, S. J.; Cosgrove, V. P.; Thwaites, D. I.

    2018-01-01

    Flattening filter free (FFF) beams have reached widespread use for clinical treatment deliveries. The usual methods for FFF beam characterisation for their quality assurance (QA) require the use of associated conventional flattened beams (cFF). Methods for QA of FFF without the need to use associated cFF beams are presented and evaluated against current methods for both FFF and cFF beams. Inflection point normalisation is evaluated against conventional methods for the determination of field size and penumbra for field sizes from 3 cm  ×  3 cm to 40 cm  ×  40cm at depths from dmax to 20 cm in water for matched and unmatched FFF beams and for cFF beams. A method for measuring symmetry in the cross plane direction is suggested and evaluated as FFF beams are insensitive to symmetry changes in this direction. Methods for characterising beam energy are evaluated and the impact of beam energy on profile shape compared to that of cFF beams. In-plane symmetry can be measured, as can cFF beams, using observed changes in profile, whereas cross-plane symmetry can be measured by acquiring profiles at collimator angles 0 and 180. Beam energy and ‘unflatness’ can be measured as with cFF beams from observed shifts in profile with changing beam energy. Normalising the inflection points of FFF beams to 55% results in an equivalent penumbra and field size measurement within 0.5 mm of conventional methods with the exception of 40 cm  ×  40 cm fields at a depth of 20 cm. New proposed methods are presented that make it possible to independently carry out set up and QA measurements on beam energy, flatness, symmetry and field size of an FFF beam without the need to reference to an equivalent flattened beam of the same energy. The methods proposed can also be used to carry out this QA for flattened beams, resulting in universal definitions and methods for MV beams. This is presented for beams produced by an Elekta linear accelerator, but is anticipated to also apply to other manufacturers’ beams.

  1. Transformation From a Conventional Clinical Microbiology Laboratory to Full Automation.

    PubMed

    Moreno-Camacho, José L; Calva-Espinosa, Diana Y; Leal-Leyva, Yoseli Y; Elizalde-Olivas, Dolores C; Campos-Romero, Abraham; Alcántar-Fernández, Jonathan

    2017-12-22

    To validate the performance, reproducibility, and reliability of BD automated instruments in order to establish a fully automated clinical microbiology laboratory. We used control strains and clinical samples to assess the accuracy, reproducibility, and reliability of the BD Kiestra WCA, the BD Phoenix, and BD Bruker MALDI-Biotyper instruments and compared them to previously established conventional methods. The following processes were evaluated: sample inoculation and spreading, colony counts, sorting of cultures, antibiotic susceptibility test, and microbial identification. The BD Kiestra recovered single colonies in less time than conventional methods (e.g. E. coli, 7h vs 10h, respectively) and agreement between both methodologies was excellent for colony counts (κ=0.824) and sorting cultures (κ=0.821). Antibiotic susceptibility tests performed with BD Phoenix and disk diffusion demonstrated 96.3% agreement with both methods. Finally, we compared microbial identification in BD Phoenix and Bruker MALDI-Biotyper and observed perfect agreement (κ=1) and identification at a species level for control strains. Together these instruments allow us to process clinical urine samples in 36h (effective time). The BD automated technologies have improved performance compared with conventional methods, and are suitable for its implementation in very busy microbiology laboratories. © American Society for Clinical Pathology 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  2. Comparative evaluation of matrix-assisted laser desorption ionisation-time of flight mass spectrometry and conventional phenotypic-based methods for identification of clinically important yeasts in a UK-based medical microbiology laboratory.

    PubMed

    Fatania, Nita; Fraser, Mark; Savage, Mike; Hart, Jason; Abdolrasouli, Alireza

    2015-12-01

    Performance of matrix-assisted laser desorption ionisation-time of flight mass spectrometry (MALDI-TOF MS) was compared in a side-by side-analysis with conventional phenotypic methods currently in use in our laboratory for identification of yeasts in a routine diagnostic setting. A diverse collection of 200 clinically important yeasts (19 species, five genera) were identified by both methods using standard protocols. Discordant or unreliable identifications were resolved by sequencing of the internal transcribed spacer region of the rRNA gene. MALDI-TOF and conventional methods were in agreement for 182 isolates (91%) with correct identification to species level. Eighteen discordant results (9%) were due to rarely encountered species, hence the difficulty in their identification using traditional phenotypic methods. MALDI-TOF MS enabled rapid, reliable and accurate identification of clinically important yeasts in a routine diagnostic microbiology laboratory. Isolates with rare, unusual or low probability identifications should be confirmed using robust molecular methods. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. Surface-region context in optimal multi-object graph-based segmentation: robust delineation of pulmonary tumors.

    PubMed

    Song, Qi; Chen, Mingqing; Bai, Junjie; Sonka, Milan; Wu, Xiaodong

    2011-01-01

    Multi-object segmentation with mutual interaction is a challenging task in medical image analysis. We report a novel solution to a segmentation problem, in which target objects of arbitrary shape mutually interact with terrain-like surfaces, which widely exists in the medical imaging field. The approach incorporates context information used during simultaneous segmentation of multiple objects. The object-surface interaction information is encoded by adding weighted inter-graph arcs to our graph model. A globally optimal solution is achieved by solving a single maximum flow problem in a low-order polynomial time. The performance of the method was evaluated in robust delineation of lung tumors in megavoltage cone-beam CT images in comparison with an expert-defined independent standard. The evaluation showed that our method generated highly accurate tumor segmentations. Compared with the conventional graph-cut method, our new approach provided significantly better results (p < 0.001). The Dice coefficient obtained by the conventional graph-cut approach (0.76 +/- 0.10) was improved to 0.84 +/- 0.05 when employing our new method for pulmonary tumor segmentation.

  4. Radiological reporting that combine continuous speech recognition with error correction by transcriptionists.

    PubMed

    Ichikawa, Tamaki; Kitanosono, Takashi; Koizumi, Jun; Ogushi, Yoichi; Tanaka, Osamu; Endo, Jun; Hashimoto, Takeshi; Kawada, Shuichi; Saito, Midori; Kobayashi, Makiko; Imai, Yutaka

    2007-12-20

    We evaluated the usefulness of radiological reporting that combines continuous speech recognition (CSR) and error correction by transcriptionists. Four transcriptionists (two with more than 10 years' and two with less than 3 months' transcription experience) listened to the same 100 dictation files and created radiological reports using conventional transcription and a method that combined CSR with manual error correction by the transcriptionists. We compared the 2 groups using the 2 methods for accuracy and report creation time and evaluated the transcriptionists' inter-personal dependence on accuracy rate and report creation time. We used a CSR system that did not require the training of the system to recognize the user's voice. We observed no significant difference in accuracy between the 2 groups and 2 methods that we tested, though transcriptionists with greater experience transcribed faster than those with less experience using conventional transcription. Using the combined method, error correction speed was not significantly different between two groups of transcriptionists with different levels of experience. Combining CSR and manual error correction by transcriptionists enabled convenient and accurate radiological reporting.

  5. An ex vivo approach to botanical-drug interactions: a proof of concept study.

    PubMed

    Wang, Xinwen; Zhu, Hao-Jie; Munoz, Juliana; Gurley, Bill J; Markowitz, John S

    2015-04-02

    Botanical medicines are frequently used in combination with therapeutic drugs, imposing a risk for harmful botanical-drug interactions (BDIs). Among the existing BDI evaluation methods, clinical studies are the most desirable, but due to their expense and protracted time-line for completion, conventional in vitro methodologies remain the most frequently used BDI assessment tools. However, many predictions generated from in vitro studies are inconsistent with clinical findings. Accordingly, the present study aimed to develop a novel ex vivo approach for BDI assessment and expand the safety evaluation methodology in applied ethnopharmacological research. This approach differs from conventional in vitro methods in that rather than botanical extracts or individual phytochemicals being prepared in artificial buffers, human plasma/serum collected from a limited number of subjects administered botanical supplements was utilized to assess BDIs. To validate the methodology, human plasma/serum samples collected from healthy subjects administered either milk thistle or goldenseal extracts were utilized in incubation studies to determine their potential inhibitory effects on CYP2C9 and CYP3A4/5, respectively. Silybin A and B, two principal milk thistle phytochemicals, and hydrastine and berberine, the purported active constituents in goldenseal, were evaluated in both phosphate buffer and human plasma based in vitro incubation systems. Ex vivo study results were consistent with formal clinical study findings for the effect of milk thistle on the disposition of tolbutamide, a CYP2C9 substrate, and for goldenseal׳s influence on the pharmacokinetics of midazolam, a widely accepted CYP3A4/5 substrate. Compared to conventional in vitro BDI methodologies of assessment, the introduction of human plasma into the in vitro study model changed the observed inhibitory effect of silybin A, silybin B and hydrastine and berberine on CYP2C9 and CYP3A4/5, respectively, results which more closely mirrored those generated in clinical study. Data from conventional buffer-based in vitro studies were less predictive than the ex vivo assessments. Thus, this novel ex vivo approach may be more effective at predicting clinically relevant BDIs than conventional in vitro methods. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. MO-FG-CAMPUS-TeP3-04: Deliverable Robust Optimization in IMPT Using Quadratic Objective Function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shan, J; Liu, W; Bues, M

    Purpose: To find and evaluate the way of applying deliverable MU constraints into robust spot intensity optimization in Intensity-Modulated- Proton-Therapy (IMPT) to prevent plan quality and robustness from degrading due to machine deliverable MU-constraints. Methods: Currently, the influence of the deliverable MU-constraints is retrospectively evaluated by post-processing immediately following optimization. In this study, we propose a new method based on the quasi-Newton-like L-BFGS-B algorithm with which we turn deliverable MU-constraints on and off alternatively during optimization. Seven patients with two different machine settings (small and large spot size) were planned with both conventional and new methods. For each patient, threemore » kinds of plans were generated — conventional non-deliverable plan (plan A), conventional deliverable plan with post-processing (plan B), and new deliverable plan (plan C). We performed this study with both realistic (small) and artificial (large) deliverable MU-constraints. Results: With small minimum MU-constraints considered, new method achieved a slightly better plan quality than conventional method (D95% CTV normalized to the prescription dose: 0.994[0.992∼0.996] (Plan C) vs 0.992[0.986∼0.996] (Plan B)). With large minimum MU constraints considered, results show that the new method maintains plan quality while plan quality from the conventional method is degraded greatly (D95% CTV normalized to the prescription dose: 0.987[0.978∼0.994] (Plan C) vs 0.797[0.641∼1.000] (Plan B)). Meanwhile, plan robustness of these two method’s results is comparable. (For all 7 patients, CTV DVH band gap at D95% normalized to the prescription dose: 0.015[0.005∼0.043] (Plan C) vs 0.012[0.006∼0.038] (Plan B) with small MU-constraints and 0.019[0.009∼0.039] (Plan C) vs 0.030[0.015∼0.041] (Plan B) with large MU-constraints) Conclusion: Positive correlation has been found between plan quality degeneration and magnitude of deliverable minimal MU. Compared to conventional post-processing method, our new method of incorporating deliverable minimal MU-constraints directly into plan optimization, can produce machine-deliverable plans with better plan qualities and non-compromised plan robustness. This research was supported by the National Cancer Institute Career Developmental Award K25CA168984, by the Fraternal Order of Eagles Cancer Research Fund Career Development Award, by The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, by Mayo Arizona State University Seed Grant and by The Kemper Marley Foundation.« less

  7. Evaluation of an improved technique for lumen path definition and lumen segmentation of atherosclerotic vessels in CT angiography.

    PubMed

    van Velsen, Evert F S; Niessen, Wiro J; de Weert, Thomas T; de Monyé, Cécile; van der Lugt, Aad; Meijering, Erik; Stokking, Rik

    2007-07-01

    Vessel image analysis is crucial when considering therapeutical options for (cardio-) vascular diseases. Our method, VAMPIRE (Vascular Analysis using Multiscale Paths Inferred from Ridges and Edges), involves two parts: a user defines a start- and endpoint upon which a lumen path is automatically defined, and which is used for initialization; the automatic segmentation of the vessel lumen on computed tomographic angiography (CTA) images. Both parts are based on the detection of vessel-like structures by analyzing intensity, edge, and ridge information. A multi-observer evaluation study was performed to compare VAMPIRE with a conventional method on the CTA data of 15 patients with carotid artery stenosis. In addition to the start- and endpoint, the two radiologists required on average 2.5 (SD: 1.9) additional points to define a lumen path when using the conventional method, and 0.1 (SD: 0.3) when using VAMPIRE. The segmentation results were quantitatively evaluated using Similarity Indices, which were slightly lower between VAMPIRE and the two radiologists (respectively 0.90 and 0.88) compared with the Similarity Index between the radiologists (0.92). The evaluation shows that the improved definition of a lumen path requires minimal user interaction, and that using this path as initialization leads to good automatic lumen segmentation results.

  8. Comparison of Silent and Conventional MR Imaging for the Evaluation of Myelination in Children

    PubMed Central

    Matsuo-Hagiyama, Chisato; Watanabe, Yoshiyuki; Tanaka, Hisashi; Takahashi, Hiroto; Arisawa, Atsuko; Yoshioka, Eri; Nabatame, Shin; Nakano, Sayaka; Tomiyama, Noriyuki

    2017-01-01

    Purpose: Silent magnetic resonance imaging (MRI) scans produce reduced acoustic noise and are considered more gentle for sedated children. The aim of this study was to compare the validity of T1- (T1W) and T2-weighted (T2W) silent sequences for myelination assessment in children with conventional spin-echo sequences. Materials and Methods: A total of 30 children (21 boys, 9 girls; age range: 1–83 months, mean age: 35.5 months, median age: 28.5 months) were examined using both silent and spin-echo sequences. Acoustic noise levels were analyzed and compared. The degree of myelination was qualitatively assessed via consensus, and T1W and T2W signal intensities were quantitatively measured by percent contrast. Results: Acoustic noise levels were significantly lower during silent sequences than during conventional sequences (P < 0.0001 for both T1W and T2W). Inter-method comparison indicated overall good to excellent agreement (T1W and T2W images, κ = 0.76 and 0.80, respectively); however, agreement was poor for cerebellar myelination on T1W images (κ = 0.14). The percent contrast of silent and conventional MRI sequences had a strong correlation (T1W, correlation coefficient [CC] = 0.76; T1W excluding the middle cerebellar peduncle, CC = 0.82; T2W, CC = 0.91). Conclusions: For brain MRI, silent sequences significantly reduced acoustic noise and provided diagnostic image quality for myelination evaluations; however, the two methods differed with respect to cerebellar delineation on T1W sequences. PMID:27795484

  9. Familiarity Vs Trust: A Comparative Study of Domain Scientists' Trust in Visual Analytics and Conventional Analysis Methods.

    PubMed

    Dasgupta, Aritra; Lee, Joon-Yong; Wilson, Ryan; Lafrance, Robert A; Cramer, Nick; Cook, Kristin; Payne, Samuel

    2017-01-01

    Combining interactive visualization with automated analytical methods like statistics and data mining facilitates data-driven discovery. These visual analytic methods are beginning to be instantiated within mixed-initiative systems, where humans and machines collaboratively influence evidence-gathering and decision-making. But an open research question is that, when domain experts analyze their data, can they completely trust the outputs and operations on the machine-side? Visualization potentially leads to a transparent analysis process, but do domain experts always trust what they see? To address these questions, we present results from the design and evaluation of a mixed-initiative, visual analytics system for biologists, focusing on analyzing the relationships between familiarity of an analysis medium and domain experts' trust. We propose a trust-augmented design of the visual analytics system, that explicitly takes into account domain-specific tasks, conventions, and preferences. For evaluating the system, we present the results of a controlled user study with 34 biologists where we compare the variation of the level of trust across conventional and visual analytic mediums and explore the influence of familiarity and task complexity on trust. We find that despite being unfamiliar with a visual analytic medium, scientists seem to have an average level of trust that is comparable with the same in conventional analysis medium. In fact, for complex sense-making tasks, we find that the visual analytic system is able to inspire greater trust than other mediums. We summarize the implications of our findings with directions for future research on trustworthiness of visual analytic systems.

  10. Combination of two-dimensional shear wave elastography with ultrasound breast imaging reporting and data system in the diagnosis of breast lesions: a new method to increase the diagnostic performance.

    PubMed

    Li, Dan-Dan; Xu, Hui-Xiong; Guo, Le-Hang; Bo, Xiao-Wan; Li, Xiao-Long; Wu, Rong; Xu, Jun-Mei; Zhang, Yi-Feng; Zhang, Kun

    2016-09-01

    To evaluate the diagnostic performance of a new method of combined two-dimensional shear wave elastography (i.e. virtual touch imaging quantification, VTIQ) and ultrasound (US) Breast Imaging Reporting and Data System (BI-RADS) in the differential diagnosis of breast lesions. From September 2014 to December 2014, 276 patients with 296 pathologically proven breast lesions were enrolled in this study. The conventional US images were interpreted by two independent readers. The diagnosis performances of BI-RADS and combined BI-RADS and VTIQ were evaluated, including the area under the receiver operating characteristic curve (AUROC), sensitivity and specificity. Observer consistency was also evaluated. Pathologically, 212 breast lesions were benign and 84 were malignant. Compared with BI-RADS alone, the AUROCs and specificities of the combined method for both readers increased significantly (AUROC: 0.862 vs. 0.693 in reader 1, 0.861 vs. 0.730 in reader 2; specificity: 91.5 % vs. 38.7 % in reader 1, 94.8 % vs. 47.2 % in reader 2; all P < .05). The Kappa value between the two readers for BI-RADS assessment was 0.614, and 0.796 for the combined method. The combined VTIQ and BI-RADS had a better diagnostic performance in the diagnosis of breast lesions in comparison with BI-RADS alone. • Combination of conventional ultrasound and elastography distinguishes breast cancers more effectively. • Combination of conventional ultrasound and elastography increases observer consistency. • BI-RADS weights more than the 2D-SWE with an increase in malignancy probability.

  11. Evaluation of physicochemical properties of root-end filling materials using conventional and Micro-CT tests.

    PubMed

    Torres, Fernanda Ferrari Esteves; Bosso-Martelo, Roberta; Espir, Camila Galletti; Cirelli, Joni Augusto; Guerreiro-Tanomaru, Juliane Maria; Tanomaru-Filho, Mario

    2017-01-01

    To evaluate solubility, dimensional stability, filling ability and volumetric change of root-end filling materials using conventional tests and new Micro-CT-based methods. 7. The results suggested correlated or complementary data between the proposed tests. At 7 days, BIO showed higher solubility and at 30 days, showed higher volumetric change in comparison with MTA (p<0.05). With regard to volumetric change, the tested materials were similar (p>0.05) at 7 days. At 30 days, they presented similar solubility. BIO and MTA showed higher dimensional stability than ZOE (p<0.05). ZOE and BIO showed higher filling ability (p<0.05). ZOE presented a higher dimensional change, and BIO had greater solubility after 7 days. BIO presented filling ability and dimensional stability, but greater volumetric change than MTA after 30 days. Micro-CT can provide important data on the physicochemical properties of materials complementing conventional tests.

  12. Comparison of conventional therapies for dentin hypersensitivity versus medical hypnosis.

    PubMed

    Eitner, Stephan; Bittner, Christian; Wichmann, Manfred; Nickenig, Hans-Joachim; Sokol, Biljana

    2010-10-01

    This study compared the efficacy of conventional treatments for dentin hypersensitivity (DHS) and hypnotherapy. During a 1-month period at an urban practice in a service area of approximately 22,000 inhabitants, all patients were examined. A total of 102 individuals were included in the evaluation. Values of 186 teeth were analyzed. The comparison of the different treatment methods (desensitizer, fluoridation, and hypnotherapy) did not show significant differences in success rates. However, a noticeable difference was observed in terms of onset and duration of effect. For both desensitizer and hypnotherapy treatments, onset of effect was very rapid. Compared to the other methods studied, hypnotherapy effects had the longest duration. In conclusion, hypnotherapy was as effective as other methods in the treatment of DHS.

  13. Three-year comparison of the polyphenol contents and antioxidant capacities in organically and conventionally produced apples ( Malus domestica Bork. Cultivar 'Golden Delicious').

    PubMed

    Stracke, Berenike A; Rüfer, Corinna E; Weibel, Franco P; Bub, Achim; Watzl, Bernhard

    2009-06-10

    The present study was performed to evaluate the polyphenol content and antioxidant capacity of apples (cv. ;Golden Delicious') grown under defined organic and conventional conditions. Apples were harvested at five comparable commercial farms over the course of three years (2004-2006). In 2005 and 2006 the antioxidant capacity was 15% higher (p < 0.05) in organically produced apples than in conventionally produced fruits. In 2005 significantly higher polyphenol concentrations were found in the organically grown apples. In 2004 and 2006 no significant differences were observed (2004, 304 +/- 68 microg/g organic vs 284 +/- 69 microg/g conventional, p = 0.18; 2005, 302 +/- 58 micro/g organic vs 253 +/- 41 microg/g conventional, p = 0.002; 2006, 402 +/- 100 microg/g organic vs 365 +/- 58 microg/g conventional, p = 0.17). Year-to-year variations in the antioxidant capacity and the polyphenol content of up to 20% were more significant than the production method found within one year. Finally, flavanols and flavonols were major determinants of the antioxidant capacities in these apples. Overall, the production method had a smaller impact on the variation in the polyphenol content and antioxidant capacity of apples than the yearly climate.

  14. Optimization of white matter tractography for pre-surgical planning and image-guided surgery.

    PubMed

    Arfanakis, Konstantinos; Gui, Minzhi; Lazar, Mariana

    2006-01-01

    Accurate localization of white matter fiber tracts in relation to brain tumors is a goal of critical importance to the neurosurgical community. White matter fiber tractography by means of diffusion tensor magnetic resonance imaging (DTI) is the only non-invasive method that can provide estimates of brain connectivity. However, conventional tractography methods are based on data acquisition techniques that suffer from image distortions and artifacts. Thus, a large percentage of white matter fiber bundles are distorted, and/or terminated early, while others are completely undetected. This severely limits the potential of fiber tractography in pre-surgical planning and image-guided surgery. In contrast, Turboprop-DTI is a technique that provides images with significantly fewer distortions and artifacts than conventional DTI data acquisition methods. The purpose of this study was to evaluate fiber tracking results obtained from Turboprop-DTI data. It was demonstrated that Turboprop may be a more appropriate DTI data acquisition technique for tracing white matter fibers than conventional DTI methods, especially in applications such as pre-surgical planning and image-guided surgery.

  15. Study of Burn Scar Extraction Automatically Based on Level Set Method using Remote Sensing Data

    PubMed Central

    Liu, Yang; Dai, Qin; Liu, JianBo; Liu, ShiBin; Yang, Jin

    2014-01-01

    Burn scar extraction using remote sensing data is an efficient way to precisely evaluate burn area and measure vegetation recovery. Traditional burn scar extraction methodologies have no well effect on burn scar image with blurred and irregular edges. To address these issues, this paper proposes an automatic method to extract burn scar based on Level Set Method (LSM). This method utilizes the advantages of the different features in remote sensing images, as well as considers the practical needs of extracting the burn scar rapidly and automatically. This approach integrates Change Vector Analysis (CVA), Normalized Difference Vegetation Index (NDVI) and the Normalized Burn Ratio (NBR) to obtain difference image and modifies conventional Level Set Method Chan-Vese (C-V) model with a new initial curve which results from a binary image applying K-means method on fitting errors of two near-infrared band images. Landsat 5 TM and Landsat 8 OLI data sets are used to validate the proposed method. Comparison with conventional C-V model, OSTU algorithm, Fuzzy C-mean (FCM) algorithm are made to show that the proposed approach can extract the outline curve of fire burn scar effectively and exactly. The method has higher extraction accuracy and less algorithm complexity than that of the conventional C-V model. PMID:24503563

  16. Standardizing lightweight deflectometer modulus measurements for compaction quality assurance

    DOT National Transportation Integrated Search

    2017-09-01

    To evaluate the compaction of unbound geomaterials under unsaturated conditions and replace the conventional methods with a practical modulus-based specification using LWD, this study examined three different LWDs, the Zorn ZFG 3000 LWD, Dynatest 303...

  17. EVALUATION OF DIOXIN EMISSIONS MONITORING SYSTEMS

    EPA Science Inventory

    Continuous samplers and real or semi-real-time continuous monitors for polychlorinated dibenzodioxins and furans provide significant advantages relative to conventional methods of extractive sampling. Continuous samplers collect long term samples over a time period of days to wee...

  18. The Westport Connecticut Integrated Transit System : service and methods demonstration program

    DOT National Transportation Integrated Search

    1979-07-01

    Report evaluates the implementation, operations and impacts of the Westport Transit District's demonstration grant to examine the feasibility of combining shared ride taxi service and other paratransit services with conventional bus services. Report ...

  19. Quantitative assessment of the T2 relaxation time of the gluteus muscles in children with Duchenne muscular dystrophy: a comparative study before and after steroid treatment.

    PubMed

    Kim, Hee Kyung; Laor, Tal; Horn, Paul S; Wong, Brenda

    2010-01-01

    To determine the feasibility of using T2 mapping as a quantitative method to longitudinally follow the disease activity in children with Duchenne muscular dystrophy (DMD) who are treated with steroids. ELEVEN BOYS WITH DMD (AGE RANGE: 5-14 years) underwent evaluation with the clinical functional score (CFS), and conventional pelvic MRI and T2 mapping before and during steroid therapy. The gluteus muscle inflammation and fatty infiltration were evaluated on conventional MRI. The histograms and mean T2 relaxation times were obtained from the T2 maps. The CFS, the conventional MRI findings and the T2 values were compared before and during steroid therapy. None of the patients showed interval change of their CFSs. On conventional MRI, none of the images showed muscle inflammation. During steroid treatment, two boys showed increased fatty infiltration on conventional MRI, and both had an increase of the mean T2 relaxation time (p < 0.05). The remaining nine boys had no increase in fatty infiltration. Of these, three showed an increased mean T2 relaxation time (p < 0.05), two showed no change and four showed a decreased mean T2 relaxation time (p < 0.05). T2 mapping is a feasible technique to evaluate the longitudinal muscle changes in those children who receive steroid therapy for DMD. The differences of the mean T2 relaxation time may reflect alterations in disease activity, and even when the conventional MRI and CFS remain stable.

  20. Comparing real-time and conventional PCR to culture-based methods for detecting and quantifying Escherichia coli O157 in cattle feces.

    PubMed

    Jacob, M E; Bai, J; Renter, D G; Rogers, A T; Shi, X; Nagaraja, T G

    2014-02-01

    Detection of Escherichia coli O157 in cattle feces has traditionally used culture-based methods; PCR-based methods have been suggested as an alternative. We aimed to determine if multiplex real-time (mq) or conventional PCR methods could reliably detect cattle naturally shedding high (≥10(4) CFU/g of feces) and low (∼10(2) CFU/g of feces) concentrations of E. coli O157. Feces were collected from pens of feedlot cattle and evaluated for E. coli O157 by culture methods. Samples were categorized as (i) high shedders, (ii) immunomagnetic separation (IMS) positive after enrichment, or (iii) culture negative. DNA was extracted pre- and postenrichment from 100 fecal samples from each category (high shedder, IMS positive, culture negative) and subjected to mqPCR and conventional PCR assays based on detecting three genes, rfbE, stx1, and stx2. In feces from cattle determined to be E. coli O157 high shedders by culture, 37% were positive by mqPCR prior to enrichment; 85% of samples were positive after enrichment. In IMS-positive samples, 4% were positive by mqPCR prior to enrichment, while 43% were positive after enrichment. In culture-negative feces, 7% were positive by mqPCR prior to enrichment, and 40% were positive after enrichment. The proportion of high shedder-positive and culture-positive (high shedder and IMS) samples were significantly different from mqPCR-positive samples before and after enrichment (P < 0.01). Similar results were observed for conventional PCR. Our data suggest that mqPCR and conventional PCR are most useful in identifying high shedder animals and may not be an appropriate substitute to culture-based methods for detection of E. coli O157 in cattle feces.

  1. [Study on friction and wear properties of dental zirconia ceramics processed by microwave and conventional sintering methods].

    PubMed

    Guoxin, Hu; Ying, Yang; Yuemei, Jiang; Wenjing, Xia

    2017-04-01

    This study evaluated the wear of an antagonist and friction and wear properties of dental zirconia ceramic that was subjected to microwave and conventional sintering methods. Ten specimens were fabricated from Lava brand zirconia and randomly assigned to microwave and conventional sintering groups. A profile tester for surface roughness was used to measure roughness of the specimens. Wear test was performed, and steatite ceramic was used as antagonist. Friction coefficient curves were recorded, and wear volume were calculated. Finally, optical microscope was used to observe the surface morphology of zirconia and steatite ceramics. Field emission scanning electron microscopy was used to observe the microstructure of zirconia. Wear volumes of microwave and conventionally sintered zirconia were (6.940±1.382)×10⁻², (7.952±1.815) ×10⁻² mm³, respectively. Moreover, wear volumes of antagonist after sintering by the considered methods were (14.189±4.745)×10⁻², (15.813±3.481)×10⁻² mm³, correspondingly. Statistically significant difference was not observed in the wear resistance of zirconia and wear volume of steatite ceramic upon exposure to two kinds of sintering methods. Optical microscopy showed that ploughed surfaces were apparent in zirconia. The wear surface of steatite ceramic against had craze, accompanied by plough. Scanning electron microscopy showed that zirconia was sintered compactly when subjected to both conventional sintering and microwave methods, whereas grains of zirconia sintered by microwave alone were smaller and more uniform. Two kinds of sintering methods are successfully used to produce dental zirconia ceramics with similar friction and wear properties.
.

  2. Retention of cardiopulmonary resuscitation skills after hands-only training versus conventional training in novices: a randomized controlled trial

    PubMed Central

    Kim, Young Joon; Cho, Youngsuk; Cho, Gyu Chong; Ji, Hyun Kyung; Han, Song Yi; Lee, Jin Hyuck

    2017-01-01

    Objective Cardiopulmonary resuscitation (CPR) training can improve performance during simulated cardiac arrest; however, retention of skills after training remains uncertain. Recently, hands-only CPR has been shown to be as effective as conventional CPR. The purpose of this study is to compare the retention rate of CPR skills in laypersons after hands-only or conventional CPR training. Methods Participants were randomly assigned to 1 of 2 CPR training methods: 80 minutes of hands-only CPR training or 180 minutes of conventional CPR training. Each participant’s CPR skills were evaluated at the end of training and 3 months thereafter using the Resusci Anne manikin with a skill-reporting software. Results In total, 252 participants completed training; there were 125 in the hands-only CPR group and 127 in the conventional CPR group. After 3 months, 118 participants were randomly selected to complete a post-training test. The hands-only CPR group showed a significant decrease in average compression rate (P=0.015), average compression depth (P=0.031), and proportion of adequate compression depth (P=0.011). In contrast, there was no difference in the skills of the conventional CPR group after 3 months. Conclusion Conventional CPR training appears to be more effective for the retention of chest compression skills than hands-only CPR training; however, the retention of artificial ventilation skills after conventional CPR training is poor. PMID:28717778

  3. Interferometry as a tool for evaluating effects of antimicrobial doses on Mycobacterium bovis growth.

    PubMed

    Machado, Rachel R P; Dutra, Rafael C; Raposo, Nádia R B; Lesche, Bernhard; Gomes, Marlei S; Duarte, Rafael S; Soares, Geraldo Luiz G; Kaplan, Maria Auxiliadora C

    2015-12-01

    Interferometry was used together with the conventional microplate resazurin assay to evaluate the antimycobacterial properties of essential oil (EO) from fruits of Pterodon emarginatus and also of rifampicin against Mycobacterium bovis. The aim of this work is not only to investigate the potential antimycobacterial activity of this EO, but also to test the interferometric method in comparison with the conventional one. The Minimum Inhibitory Concentration (MIC) values of EO (625 μg/mL) and rifampicin (4 ng/mL) were firstly identified with the microplate method. These values were used as parameters in Drug Susceptibility Tests (DST) with interferometry. The interferometry confirmed the MIC value of EO identified with microplate and revealed a bacteriostatic behavior for this concentration. At 2500 μg/mL interferometry revealed bactericidal activity of the EO. Mycobacterial growth was detected with interferometry at 4 ng/mL of rifampicin and even at higher concentrations. One important difference is that the interferometric method preserves the sample, so that after weeks of quantitative observation, the sample can be used to evaluate the bactericidal activity of the tested drug. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Evaluation of maternal serum alpha-foetoprotein assay using dry blood spot samples.

    PubMed

    González, C; Guerrero, J M; Elorza, F L; Molinero, P; Goberna, R

    1988-02-01

    The quantification of alpha-foetoprotein in dry blood spots from pregnant women was evaluated, using a conventional radioimmunoassay (RIA) with a monospecific antibody. The stability of alpha-foetoprotein in dry blood spots on filter paper was evaluated with respect to mailing, distances travelled, and the existence of high summer temperatures in our region. The results obtained show that the blood alpha-foetoprotein is stable on dry filter spots sent by mail and is stable for up to four weeks at 4, 25 and 37 degrees C. The analytical method used has a minimal detectable concentration of 10 +/- 1.9 international kilo-units/l. Both inter- and intra-assay variabilities are smaller than 10% and this method can provide results comparable with those of conventional serum assays. Results from dry blood spots and serum samples (the latter analysed by both RIA and two-site enzyme immunoassay) exhibited a good correlation (r = 0.98 and r = 0.97, p less than 0.001). The design of the assay and the nature of the samples make this method suitable for a screening programmes for the antenatal detection of open neural tube defects.

  5. The comparison of assessment of pigeon semen motility and sperm concentration by conventional methods and the CASA system (HTM IVOS).

    PubMed

    Klimowicz, M D; Nizanski, W; Batkowski, F; Savic, M A

    2008-07-01

    The aim of these experiments was to compare conventional, microscopic methods of evaluating pigeon sperm motility and concentration to those measured by computer-assisted sperm analysis (CASA system). Semen was collected twice a week from two groups of pigeons, each of 40 males (group I: meat-type breed; group II: fancy pigeon) using the lumbo-sacral and cloacal region massage method. Ejaculates collected in each group were diluted 1:100 in BPSE solution and divided into two equal samples. One sample was examined subjectively by microscope and the second one was analysed using CASA system. The sperm concentration was measured by CASA using the anti-collision (AC) system and fluorescent staining (IDENT). There were not any significant differences between the methods of evaluation of sperm concentration. High positive correlations in both groups were observed between the sperm concentration estimated by Thom counting chamber and AC (r=0.87 and r=0.91, respectively), and between the sperm concentration evaluated by Thom counting chamber and IDENT (r=0.85 and r=0.90, respectively). The mean values for CASA measurement of proportion of motile spermatozoa (MOT) and progressive movement (PMOT) were significantly lower than the values estimated subjectively in both groups of pigeons (p< or =0.05 and p< or =0.01, respectively). Positive correlations in MOT and PMOT were noted between both methods of evaluation. The CASA system is very rapid, objective and sensitive method in detecting subtle motility characteristics as well as sperm concentration and is recommended for future research into pigeon semen.

  6. Feasibility of ballistic strengthening exercises in neurologic rehabilitation.

    PubMed

    Williams, Gavin; Clark, Ross A; Hansson, Jessica; Paterson, Kade

    2014-09-01

    Conventional methods for strength training in neurologic rehabilitation are not task specific for walking. Ballistic strength training was developed to improve the functional transfer of strength training; however, no research has investigated this in neurologic populations. The aim of this pilot study was to evaluate the feasibility of applying ballistic principles to conventional leg strengthening exercises in individuals with mobility limitations as a result of neurologic injuries. Eleven individuals with neurologic injuries completed seated and reclined leg press using conventional and ballistic techniques. A 2 × 2 repeated-measures analysis of variance was used to compare power measures (peak movement height and peak velocity) between exercises and conditions. Peak jump velocity and peak jump height were greater when using the ballistic jump technique rather than the conventional concentric technique (P < 0.01). These findings suggest that when compared with conventional strengthening exercises, the incorporation of ballistic principles was associated with increased peak height and peak velocities.

  7. The effect of a whole-body vibration therapy on the sitting balance of subacute stroke patients: a randomized controlled trial.

    PubMed

    Lee, Jong Hwa; Kim, Sang Beom; Lee, Kyeong Woo; Lee, Sook Joung; Park, Hyuntae; Kim, Dong Won

    2017-09-01

    The use of a whole-body vibration (WBV) therapy has recently been applied and investigated as a rehabilitation method for subacute stroke patients. To evaluate the effects of a WBV therapy on recovery of balance in subacute stroke patients who were unable to gain sitting balance. The conventional rehabilitation group (CG) received conventional physical therapy, including sitting balance training by a physical therapist, for 30 min a one session, for twice a day for five days a week for two weeks. The whole-body vibration group (VG) received one session of conventional physical therapy, and received WBV therapy instead of conventional physical therapy for 30 min a day for five days a week for two weeks. There were 15 patients in the CG and 15 patients in the VG who completed the two-week therapy. After the two-week therapy, both groups showed functional improvement. Patients in the VG improved functional ambulation categories, Berg balance scale, trunk impairment scale scores. But, no statistically significant correlations between the therapeutic methods and outcomes were observed in either group. Our results suggest that WBV therapy led to improvement of the recovery in balance recovery for subacute stroke patients. Because the WBV therapy was as effective as conventional physical therapy, we can consider a WBV therapy as a clinical method to improve the sitting balance of subacute stoke patients.

  8. Construction and evaluation of ion selective electrodes for nitrate with a summing operational amplifier. Application to tobacco analysis.

    PubMed

    Pérez-Olmos, R; Rios, A; Fernández, J R; Lapa, R A; Lima, J L

    2001-01-05

    In this paper, the construction and evaluation of an electrode selective to nitrate with improved sensitivity, constructed like a conventional electrode (ISE) but using an operational amplifier to sum the potentials supplied by four membranes (ESOA) is described. The two types of electrodes, without an inner reference solution, were constructed using tetraoctylammonium bromide as sensor, dibutylphthalate as solvent mediator and PVC as plastic matrix, the membranes obtained directly applied onto a conductive epoxy resin support. After the comparative evaluation of their working characteristics they were used in the determination of nitrate in different types of tobacco. The limit of detection of the direct potentiometric method developed was found to be 0.18 g kg(-1) and the precision and accuracy of the method, when applied to eight different samples of tobacco, expressed in terms of mean R.S.D. and average percentage of spike recovery was 0.6 and 100.3%, respectively. The comparison of variances showed, on all ocassions, that the results obtained by the ESOA were similar to those obtained by the conventional ISE, but with higher precision. Linear regression analysis showed good agreement (r=0.9994) between the results obtained by the developed potentiometric method and those of a spectrophotometric method based on brucine, adopted as reference method, when applied simultaneously to 32 samples of different types of tobacco.

  9. Cross-correlation analysis of pulse wave propagation in arteries: in vitro validation and in vivo feasibility.

    PubMed

    Nauleau, Pierre; Apostolakis, Iason; McGarry, Matthew; Konofagou, Elisa

    2018-05-29

    The stiffness of the arteries is known to be an indicator of the progression of various cardiovascular diseases. Clinically, the pulse wave velocity (PWV) is used as a surrogate for arterial stiffness. Pulse wave imaging (PWI) is a non-invasive, ultrasound-based imaging technique capable of mapping the motion of the vessel walls, allowing the local assessment of arterial properties. Conventionally, a distinctive feature of the displacement wave (e.g. the 50% upstroke) is tracked across the map to estimate the PWV. However, the presence of reflections, such as those generated at the carotid bifurcation, can bias the PWV estimation. In this paper, we propose a two-step cross-correlation based method to characterize arteries using the information available in the PWI spatio-temporal map. First, the area under the cross-correlation curve is proposed as an index for locating the regions of different properties. Second, a local peak of the cross-correlation function is tracked to obtain a less biased estimate of the PWV. Three series of experiments were conducted in phantoms to evaluate the capabilities of the proposed method compared with the conventional method. In the ideal case of a homogeneous phantom, the two methods performed similarly and correctly estimated the PWV. In the presence of reflections, the proposed method provided a more accurate estimate than conventional processing: e.g. for the soft phantom, biases of  -0.27 and -0.71 m · s -1 were observed. In a third series of experiments, the correlation-based method was able to locate two regions of different properties with an error smaller than 1 mm. It also provided more accurate PWV estimates than conventional processing (biases:  -0.12 versus -0.26 m · s -1 ). Finally, the in vivo feasibility of the proposed method was demonstrated in eleven healthy subjects. The results indicate that the correlation-based method might be less precise in vivo but more accurate than the conventional method.

  10. Evaluation of new automated syphilis test reagents 'IMMUNOTICLES AUTO3' series: performance, biochemical reactivity, and clinical significance.

    PubMed

    Yukimasa, Nobuyasu; Miura, Keisuke; Miyagawa, Yukiko; Fukuchi, Kunihiko

    2015-01-01

    Automated nontreponemal and treponemal test reagents based on the latex agglutination method (immunoticles auto3 RPR: ITA3RPR and immunoticles auto3 TP: ITA3TP) have been developed to improve the issues of conventional manual methods such as their subjectivity, a massive amount of assays, and so on. We evaluated these reagents in regards to their performance, reactivity to antibody isotype, and their clinical significance. ITA3RPR and ITA3TP were measured using a clinical chemistry analyzer. Reactivity to antibody isotype was examined by gel filtration analysis. ITA3RPR and ITA3TP showed reactivity to both IgM- and IgG-class antibodies and detected early infections. ITA3RPR was verified to show a higher reactivity to IgM-class antibodies than the conventional methods. ITA3RPR correlated with VDRL in the high titer range, and measurement values decreased with treatment. ITA3RPR showed a negative result earlier after treatment than conventional methods. ITA3TP showed high specificity and did not give any false-negative reaction. Significant differences in the measurement values of ITA3RPR between the infective and previous group were verified. The double test of ITA3RPR and ITA3TP enables efficient and objective judgment for syphilis diagnosis and treatments, achieving clinical availability. Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  11. A multiplex PCR assay for the rapid and sensitive detection of methicillin-resistant Staphylococcus aureus and simultaneous discrimination of Staphylococcus aureus from coagulase-negative staphylococci.

    PubMed

    Xu, Benjin; Liu, Ling; Liu, Li; Li, Xinping; Li, Xiaofang; Wang, Xin

    2012-11-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a global health concern, which had been detected in food and food production animals. Conventional testing for detection of MRSA takes 3 to 5 d to yield complete information of the organism and its antibiotic sensitivity pattern. So, a rapid method is needed to diagnose and treat the MRSA infections. The present study focused on the development of a multiplex PCR assay for the rapid and sensitive detection of MRSA. The assay simultaneously detected 4 genes, namely, 16S rRNA of the Staphylococcus genus, femA of S. aureus, mecA that encodes methicillin resistance, and one internal control. It was rapid and yielded results within 4 h. The analytical sensitivity and specificity of the multiplex PCR assay was evaluated by comparing it with the conventional method. The analytical sensitivity of the multiplex PCR assay at the DNA level was 10 ng DNA. The analytical specificity was evaluated with 10 reference staphylococci strains and was 100%. The diagnostic evaluation of MRSA was carried out using 360 foodborne staphylococci isolates, and showed 99.1% of specificity, 96.4% of sensitivity, 97.5% of positive predictive value, and 97.3% of negative predictive value compared to the conventional method. The inclusion of an internal control in the multiplex PCR assay is important to exclude false-negative cases. This test can be used as an effective diagnostic and surveillance tool to investigate the spread and emergence of MRSA. © 2012 Institute of Food Technologists®

  12. Colon Capsule Endoscopy: Where Are We and Where Are We Going

    PubMed Central

    Han, Yoo Min; Im, Jong Pil

    2016-01-01

    Colon capsule endoscopy (CCE) is a noninvasive technique for diagnostic imaging of the colon. It does not require air inflation or sedation and allows minimally invasive and painless colonic evaluation. The role of CCE is rapidly evolving; for example, for colorectal screening (colorectal cancer [CRC]) in average-risk patients, in patients with an incomplete colonoscopy, in patients refusing a conventional colonoscopy, and in patients with contraindications for conventional colonoscopy. In this paper, we comprehensively review the technical characteristics and procedure of CCE and compare CCE with conventional methods such as conventional colonoscopy or computed tomographic colonography. Future expansion of CCE in the area of CRC screening for the surveillance of polyps and adenomatous lesions and for assessment of inflammatory bowel disease is also discussed. PMID:27653441

  13. Retention of denture bases fabricated by three different processing techniques – An in vivo study

    PubMed Central

    Chalapathi Kumar, V. H.; Surapaneni, Hemchand; Ravikiran, V.; Chandra, B. Sarat; Balusu, Srilatha; Reddy, V. Naveen

    2016-01-01

    Aim: Distortion due to Polymerization shrinkage compromises the retention. To evaluate the amount of retention of denture bases fabricated by conventional, anchorized, and injection molding polymerization techniques. Materials and Methods: Ten completely edentulous patients were selected, impressions were made, and master cast obtained was duplicated to fabricate denture bases by three polymerization techniques. Loop was attached to the finished denture bases to estimate the force required to dislodge them by retention apparatus. Readings were subjected to nonparametric Friedman two-way analysis of variance followed by Bonferroni correction methods and Wilcoxon matched-pairs signed-ranks test. Results: Denture bases fabricated by injection molding (3740 g), anchorized techniques (2913 g) recorded greater retention values than conventional technique (2468 g). Significant difference was seen between these techniques. Conclusions: Denture bases obtained by injection molding polymerization technique exhibited maximum retention, followed by anchorized technique, and least retention was seen in conventional molding technique. PMID:27382542

  14. Change in Elasticity Caused by Flow-Mediated Dilation Measured Only for Intima-Media Region of Brachial Artery

    NASA Astrophysics Data System (ADS)

    Sugimoto, Masataka; Hasegawa, Hideyuki; Kanai, Hiroshi

    2005-08-01

    Endothelial dysfunction is considered to be an initial step of arteriosclerosis [R. Ross: N. Engl. J. Med. 340 (2004) 115]. For the assessment of the endothelium function, brachial artery flow-mediated dilation (FMD) caused by increased blood flow has been evaluated with ultrasonic diagnostic equipment. In the case of conventional methods, the change in artery diameter caused by FMD is measured [M. Hashimoto et al.: Circulation 92 (1995) 3431]. Although the arterial wall has a layered structure (intima, media, and adventitia), such a structure is not taken into account in conventional methods because the change in diameter depends on the characteristic of the entire wall. However, smooth muscle present only in the media contributes to FMD, whereas the collagen-rich hard adventitia does not contribute. In this study, we measure the change in elasticity of only the intima-media region including smooth muscle using the phased tracking method [H. Kanai et al.: IEEE Trans. Ultrason. Ferroelectr. Freq. Control 43 (1996) 791]. From the change in elasticity, FMD measured only for the intima-media region by our proposed method was found to be more sensitive than that measured for the entire wall by the conventional method.

  15. Evaluation of permeable fractures in rock aquifers

    NASA Astrophysics Data System (ADS)

    Bok Lee, Hang

    2015-04-01

    In this study, the practical usefulness and fundamental applicability of a self-potential (SP) method for identifying the permeable fractures were evaluated by a comparison of SP methods with other geophysical logging methods and hydraulic tests. At a 10 m-shallow borehole in the study site, the candidates of permeable fractures crossing the borehole were first determined by conventional geophysical methods such as an acoustic borehole televiwer, temperature, electrical conductivity and gamma-gamma loggings, which was compared to the analysis by the SP method. Constant pressure injection and recovery tests were conducted for verification of the hydraulic properties of the fractures identified by various logging methods. The acoustic borehole televiwer and gamma-gamma loggings detected the open space or weathering zone within the borehole, but they cannot prove the possibility of a groundwater flow through the detected fractures. The temperature and electrical conductivity loggings had limitations to detect the fractured zones where groundwater in the borehole flows out to the surrounding rock aquifers. Comparison of results from different methods showed that there is a best correlation between the distribution of hydraulic conductivity and the variation of the SP signals, and the SP logging can estimate accurately the hydraulic activity as well as the location of permeable fractures. Based on the results, the SP method is recommended for determining the hydraulically-active fractures rather than other conventional geophysical loggings. This self-potential method can be effectively applied in the initial stage of a site investigation which selects the optimal location and evaluates the hydrogeological property of fractures in target sites for the underground structure including the geothermal reservoir and radioactive waste disposal.

  16. Gram staining apparatus for space station applications.

    PubMed Central

    Molina, T C; Brown, H D; Irbe, R M; Pierson, D L

    1990-01-01

    A self-contained, portable Gram staining apparatus (GSA) has been developed for use in the microgravity environment on board the Space Station Freedom. Accuracy and reproducibility of this apparatus compared with the conventional Gram staining method were evaluated by using gram-negative and gram-positive controls and different species of bacteria grown in pure cultures. A subsequent study was designed to assess the performance of the GSA with actual specimens. A set of 60 human and environmental specimens was evaluated with the GSA and the conventional Gram staining procedure. Data obtained from these studies indicated that the GSA will provide the Gram staining capability needed for the microgravity environment of space. Images PMID:1690529

  17. Water quality assessment of the Li Canal using a functional fuzzy synthetic evaluation model.

    PubMed

    Feng, Yan; Ling, Liu

    2014-07-01

    Through introducing functional data analysis (FDA) theory into the conventional fuzzy synthetic evaluation (FSE) method, the functional fuzzy synthetic evaluation (FFSE) model is established. FFSE keeps the property of the conventional FSE that the fuzziness in the water quality condition can be suitably measured. Furthermore, compared with FSE, FFSE has the following advantages: (1) FFSE requires fewer conditions for observation, for example, pollutants can be monitored at different times, and missing data is accepted; (2) the dynamic variation of the water quality condition can be represented more comprehensively and intuitively. The procedure of FFSE is discussed and the water quality of the Li Canal in 2012 is evaluated as an illustration. The synthetic classification of the Li Canal is "II" in January, February and July, and "I" in other months, which can satisfy the requirement of the Chinese South-to-North Water Diversion Project.

  18. Visualizing Similarity of Appearance by Arrangement of Cards

    PubMed Central

    Nakatsuji, Nao; Ihara, Hisayasu; Seno, Takeharu; Ito, Hiroshi

    2016-01-01

    This study proposes a novel method to extract the configuration of the psychological space by directly measuring subjects' similarity rating without computational work. Although multidimensional scaling (MDS) is well-known as a conventional method for extracting the psychological space, the method requires many pairwise evaluations. The times taken for evaluations increase in proportion to the square of the number of objects in MDS. The proposed method asks subjects to arrange cards on a poster sheet according to the degree of similarity of the objects. To compare the performance of the proposed method with the conventional one, we developed similarity maps of typefaces through the proposed method and through non-metric MDS. We calculated the trace correlation coefficient among all combinations of the configuration for both methods to evaluate the degree of similarity in the obtained configurations. The threshold value of trace correlation coefficient for statistically discriminating similar configuration was decided based on random data. The ratio of the trace correlation coefficient exceeding the threshold value was 62.0% so that the configurations of the typefaces obtained by the proposed method closely resembled those obtained by non-metric MDS. The required duration for the proposed method was approximately one third of the non-metric MDS's duration. In addition, all distances between objects in all the data for both methods were calculated. The frequency for the short distance in the proposed method was lower than that of the non-metric MDS so that a relatively small difference was likely to be emphasized among objects in the configuration by the proposed method. The card arrangement method we here propose, thus serves as a easier and time-saving tool to obtain psychological structures in the fields related to similarity of appearance. PMID:27242611

  19. Evaluation of TECRA® broth, Bolton broth and direct plating for recovery of Campylobacter spp, from broiler carcass rinsates from several commercial processing plants

    USDA-ARS?s Scientific Manuscript database

    The purpose of this study was to compare a conventional culture broth method (Bolton enrichment broth containing lysed horse blood), a newly developed proprietary broth method (TECRA® Campylobacter enrichment) and direct plating for Campylobacter spp. recovery from chicken carcass rinses. Whole car...

  20. [Factors Affecting Long-Term Cosmetic Results after Minimally Invasive Video-Assisted Thyroidectomy and Conventional Thyroid Surgery].

    PubMed

    Sahm, Maik; Otto, Ronny; Pross, Matthias; Mantke, Rene

    2018-06-25

    Approximately 90,000 thyroid operations are performed in Germany each year. Minimally invasive video-assisted thyroidectomy (MIVAT) accounts for 5 - 10% of these operations. There are few data that compare long-term cosmetic results after MIVAT to those after conventional surgery. Current systematic reviews show no advantage for MIVAT. The goal of this study was to analyse the long-term postoperative results in both procedures and the evaluation of relevant factors. The analysis of the long-term results is based on follow-up examinations using a validated method for scar appraisal (POSAS). Cohort analysis was performed on MIVAT operations in our hospital between 2004 and 2011 and conventional thyroid operations in 2011. Follow-up examination data were analysed from 117 patients from the MIVAT group and 102 patients from the conventional group. The follow-up examination was performed with a mean of 23.1 vs. 23.6 months postoperatively (MIVAT vs. conventional). The Friedman Test showed that scar pigmentation (mean rank 4.79) and scar surface structure (mean rank 3.62) were the deciding factors influencing the long-term cosmetic results. Both MIVAT and conventional surgery gave very good long-term cosmetic results. From the patient's perspective, there is no significant advantage with conventional surgery. The evaluation of the long-term results largely depends on factors such as scar pigmentation and surface structure that can only be influenced to a limited extent by the surgical procedure. Georg Thieme Verlag KG Stuttgart · New York.

  1. A comparison of piezosurgery with conventional techniques for internal osteotomy.

    PubMed

    Koçak, I; Doğan, R; Gökler, O

    2017-06-01

    To compare conventional osteotomy with the piezosurgery medical device, in terms of postoperative edema, ecchymosis, pain, operation time, and mucosal integrity, in rhinoplasty patients. In this prospective study, 49 rhinoplasty patients were randomly divided into two groups according to osteotomy technique used, either conventional osteotomy or piezosurgery. For all patients, the total duration of the operation was recorded, and photographs were taken and scored for ecchymosis and edema on postoperative days 2, 4, and 7. In addition, pain level was evaluated on postoperative day 2, and mucosal integrity was assessed on day 4. All scoring and evaluation was conducted by a physician who was blinded to the osteotomy procedure. In the piezosurgery group, edema scores on postoperative day 2 and ecchymosis scores on postoperative days 2, 4, and 7 were significantly lower than in the conventional osteotomy group (p < 0.05). On postoperative day 2, the pain level was lower in the piezosurgery group than in the conventional osteotomy group (p < 0.05). In an endoscopic examination on postoperative day 4, while 24% of the patients in the conventional osteotomy group had mucosal damage, no such damage was observed in the piezosurgery group. When total operation duration was compared, there was no significant difference between the groups (p > 0.05). Piezosurgery is a safe osteotomy method, with less edema (in the early postoperative period) and ecchymosis compared with conventional osteotomy, as well as less pain, a similar operation duration, and no mucosal damage.

  2. Diagnostic utility of the cell block method versus the conventional smear study in pleural fluid cytology.

    PubMed

    Shivakumarswamy, Udasimath; Arakeri, Surekha U; Karigowdar, Mahesh H; Yelikar, Br

    2012-01-01

    The cytological examinations of serous effusions have been well-accepted, and a positive diagnosis is often considered as a definitive diagnosis. It helps in staging, prognosis and management of the patients in malignancies and also gives information about various inflammatory and non-inflammatory lesions. Diagnostic problems arise in everyday practice to differentiate reactive atypical mesothelial cells and malignant cells by the routine conventional smear (CS) method. To compare the morphological features of the CS method with those of the cell block (CB) method and also to assess the utility and sensitivity of the CB method in the cytodiagnosis of pleural effusions. The study was conducted in the cytology section of the Department of Pathology. Sixty pleural fluid samples were subjected to diagnostic evaluation for over a period of 20 months. Along with the conventional smears, cell blocks were prepared by using 10% alcohol-formalin as a fixative agent. Statistical analysis with the 'z test' was performed to identify the cellularity, using the CS and CB methods. Mc. Naemer's χ(2)test was used to identify the additional yield for malignancy by the CB method. Cellularity and additional yield for malignancy was 15% more by the CB method. The CB method provides high cellularity, better architectural patterns, morphological features and an additional yield of malignant cells, and thereby, increases the sensitivity of the cytodiagnosis when compared with the CS method.

  3. Strain elastography of abnormal axillary nodes in breast cancer patients does not improve diagnostic accuracy compared with conventional ultrasound alone.

    PubMed

    Park, Young Mi; Fornage, Bruno D; Benveniste, Ana Paula; Fox, Patricia S; Bassett, Roland L; Yang, Wei Tse

    2014-12-01

    The purpose of this study was to determine the diagnostic value of strain elastography (SE) alone and in combination with gray-scale ultrasound in the diagnosis of benign versus metastatic disease for abnormal axillary lymph nodes in breast cancer patients. Patients with breast cancer and axillary lymph nodes suspicious for metastatic disease on conventional ultrasound who underwent SE of the suspicious node before ultrasound-guided fine-needle aspiration biopsy (FNAB) were included in this study. On conventional ultrasound, the long- and short-axis diameters, long-axis-to-short-axis ratio, cortical echogenicity, thickness, and evenness were documented. The nodal vascularity was assessed on power Doppler imaging. Elastograms were evaluated for the percentage of black (hard) areas in the lymph node, and the SE-ultrasound size ratio was calculated. Two readers assessed the images independently and then in consensus in cases of disagreement. ROC AUCs were calculated for conventional ultrasound, SE, and both methods combined. Interreader reliability was assessed using kappa statistics. A total of 101 patients with 104 nodes were examined; 35 nodes were benign, and 69 had metastases. SE alone showed a significantly lower AUC (62%) than did conventional ultrasound (92%) (p<0.001). There was no difference between the AUC of conventional ultrasound and the AUC of the combination of conventional ultrasound and SE (93%) (p=0.16). Interreader reliability was moderate for all variables (κ≥0.60) except the SE-ultrasound size ratio (κ=0.35). Added SE does not improve the diagnostic ability of conventional ultrasound when evaluating abnormal axillary lymph nodes.

  4. Evaluation of the force generated by gradual deflection of orthodontic wires in conventional metallic, esthetic, and self-ligating brackets

    PubMed Central

    Francisconi, Manoela Fávaro; Janson, Guilherme; Henriques, José Fernando Castanha; de Freitas, Karina Maria Salvatore

    2016-01-01

    ABSTRACT Objective: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual increase in wire diameter and deflection and comparing different combinations in the different deflections. Material and Methods: Specimens were set in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using the ISO 15841 protocol. Data were subjected to One-way ANOVA, followed by Tukey tests (p<0.05). Results: Self-ligating brackets presented the most similar behavior to each other. For conventional brackets there was no consistent behavior for any of the deflections studied. Conclusions: Self-ligating brackets presented the most consistent and predictable results while conventional brackets, as esthetic brackets, showed very different patterns of forces. Self-ligating brackets showed higher strength in all deflections when compared with the others, in 0.020-inch wires. PMID:27812620

  5. Method for automatic localization of MR-visible markers using morphological image processing and conventional pulse sequences: feasibility for image-guided procedures.

    PubMed

    Busse, Harald; Trampel, Robert; Gründer, Wilfried; Moche, Michael; Kahn, Thomas

    2007-10-01

    To evaluate the feasibility and accuracy of an automated method to determine the 3D position of MR-visible markers. Inductively coupled RF coils were imaged in a whole-body 1.5T scanner using the body coil and two conventional gradient echo sequences (FLASH and TrueFISP) and large imaging volumes up to (300 mm(3)). To minimize background signals, a flip angle of approximately 1 degrees was used. Morphological 2D image processing in orthogonal scan planes was used to determine the 3D positions of a configuration of three fiducial markers (FMC). The accuracies of the marker positions and of the orientation of the plane defined by the FMC were evaluated at various distances r(M) from the isocenter. Fiducial marker detection with conventional equipment (pulse sequences, imaging coils) was very reliable and highly reproducible over a wide range of experimental conditions. For r(M)

  6. Evaluation of the Amount of Debris extruded apically by using Conv-entional Syringe, Endovac and Ultrasonic Irrigation Technique: An In Vitro Study

    PubMed Central

    Tambe, Varsha H; Nagmode, Pradnya S; Vishwas, Jayshree R; P, Saujanya K; Angadi, Prabakar; Ali, Fareedi Mukram

    2013-01-01

    Background: To compare the amount of debris extruded apically by using conventional syringe, Endovac & Ultrasonic irrigation. Materials & Methods: Thirty freshly extracted mandibular premolars were selected, working length was determined and mounted in a debris and collection apparatus. The canals were prepared. After each instrument change, 1 ml. of 3% sodium hypochlorite was used as irrigation. Debris extruded apically by using conventional syringe, endovac& ultrasonic irrigation tech, was measured using the electronic balance to determine its weight and statistical analysis was performed. The mean difference between the groups was determined using statistical analysis within the groups &between the groups for equal variances. Results: Among all the groups, significantly less debris were found apically in the Endovac group (0.96) compared to conventional and ultrasonic group (1.23) syringe. Conclusion: The present study showed that endovac system extrudes less amount of debris apically as compared to ultrasonic followed by conventional so incidence of flare up can be reduce by using endovac irrigation system. How to cite this article: Tambe V H, Nagmode P S, Vishwas J R, Saujanya K P, Angadi P, Ali F M. Evaluation of the Amount of Debris extruded apically by using Conventional Syringe, Endovac and Ultrasonic Irrigation Technique: An In Vitro Study. J Int Oral Health 2013; 5(3):63-66. PMID:24155604

  7. Alterations in plaque accumulation and gingival inflammation promoted by treatment with self-ligating and conventional orthodontic brackets

    PubMed Central

    Cardoso, Mauricio de Almeida; Saraiva, Patrícia Pinto; Maltagliati, Liliana Ávila; Rhoden, Fernando Kleinübing; Costa, Carla Cristina Alvarenga; Normando, David; Capelozza, Leopoldino

    2015-01-01

    OBJECTIVE: The aim of the present study was to evaluate, comparatively, the periodontal response during orthodontic treatment performed with self-ligating and conventional brackets. METHODS: Sixteen Caucasian individuals of both sexes, aged between 12 and 16 years old and in permanent dentition were selected. Eight individuals were treated with conventional brackets installed on the lower dental arch and self-ligating brackets on the upper arch. Another eight individuals received self-ligating brackets in the lower arch and conventional brackets in the upper arch. The subjects received material and instructions for oral hygiene. Visible plaque index (VPI), gingival bleeding index (GBI) and clinical attachment level (CAL) were evaluated just after installation of orthodontic appliances, and 30, 60 and 180 days later. Mann-Whitney test was used to compare differences between groups (self-ligating and conventional), two-way ANOVA followed by Tukey's test was used to assess CAL at each site of each tooth. Significance level was set at 5%. RESULTS: No significant changes were found with regard to the assessed parameters (VPI, GBI and CAL) in either one of the systems. CONCLUSION: No significant changes were found with regard to the periodontal response to orthodontic treatment for the variables assessed and between subjects receiving passive self-ligating and conventional brackets. All individuals had received oral hygiene instructions and had their periodontal conditions monitored. PMID:25992985

  8. Accuracy improvement in measurement of arterial wall elasticity by applying pulse inversion to phased-tracking method

    NASA Astrophysics Data System (ADS)

    Miyachi, Yukiya; Arakawa, Mototaka; Kanai, Hiroshi

    2018-07-01

    In our studies on ultrasonic elasticity assessment, minute change in the thickness of the arterial wall was measured by the phased-tracking method. However, most images in carotid artery examinations contain multiple-reflection noise, making it difficult to evaluate arterial wall elasticity precisely. In the present study, a modified phased-tracking method using the pulse inversion method was examined to reduce the influence of the multiple-reflection noise. Moreover, aliasing in the harmonic components was corrected by the fundamental components. The conventional and proposed methods were applied to a pulsated tube phantom mimicking the arterial wall. For the conventional method, the elasticity was 298 kPa without multiple-reflection noise and 353 kPa with multiple-reflection noise on the posterior wall. That of the proposed method was 302 kPa without multiple-reflection noise and 297 kPa with multiple-reflection noise on the posterior wall. Therefore, the proposed method was very robust against multiple-reflection noise.

  9. Comparison of conventional culture method and fluorescent in situ hybridization technique for detection of Listeria spp. in ground beef, turkey, and chicken breast fillets in İzmir, Turkey.

    PubMed

    Baysal, Ayse Handan

    2014-12-01

    The occurrence of Listeria species in refrigerated fresh chicken breast fillet, turkey breast fillet, and ground beef was evaluated, comparing the conventional culture method and fluorescent in situ hybridization (FISH). FISH uses hybridization of a nucleic acid sequence target of a microorganism with a specific DNA probe labeled with a fluorochrome and imaging by a fluorescence microscope. First, Listeria was inoculated in chicken breast fillet, turkey breast fillet, or ground beef, and the applicability of the FISH method was evaluated. Second, Listeria was detected in fresh chicken breast fillet, turkey breast fillet, and ground beef by culture and FISH methods. Listeria was isolated from 27 (37.4%) of 216 samples by the standard culture method, whereas FISH detected 25 (24.7%) preenriched samples. Of these isolates, 17 (63%) were L. innocua, 6 (22%) L. welshimeri, and 4 (14.8%) L. seeligeri. Overall, the prevalences of Listeria spp. found with the conventional culture method in chicken breast fillet, turkey breast fillet, and ground beef were 9.7, 6.9, and 20.8%, whereas with the FISH technique these values were 11.1, 6.9, and 16.7%, respectively. The molecular FISH technique appears to be a cheap, sensitive, and time-efficient procedure that could be used for routine detection of Listeria spp. in meat. This study showed that retail raw meats are potentially contaminated with Listeria spp. and are, thus, vehicles for transmitting diseases caused by foodborne pathogens, underlining the need for increased precautions, such as implementation of hazard analysis and critical control points and consumer food safety education.

  10. THE PRODUCTION AND EVALUATION OF THREE COMPUTER-BASED ECONOMICS GAMES FOR THE SIXTH GRADE. FINAL REPORT.

    ERIC Educational Resources Information Center

    WING, RICHARD L.; AND OTHERS

    THE PURPOSE OF THE EXPERIMENT WAS TO PRODUCE AND EVALUATE 3 COMPUTER-BASED ECONOMICS GAMES AS A METHOD OF INDIVIDUALIZING INSTRUCTION FOR GRADE 6 STUDENTS. 26 EXPERIMENTAL SUBJECTS PLAYED 2 ECONOMICS GAMES, WHILE A CONTROL GROUP RECEIVED CONVENTIONAL INSTRUCTION ON SIMILAR MATERIAL. IN THE SUMERIAN GAME, STUDENTS SEATED AT THE TYPEWRITER TERMINALS…

  11. DOE/DOT Crude Oil Characterization Research Study, Task 2 Test Report on Evaluating Crude Oil Sampling and Analysis Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lord, David; Allen, Ray; Rudeen, David

    The Crude Oil Characterization Research Study is designed to evaluate whether crude oils currently transported in North America, including those produced from "tight" formations, exhibit physical or chemical properties that are distinct from conventional crudes, and how these properties associate with combustion hazards with may be realized during transportation and handling.

  12. [Clinical and radiographic outcomes of navigation-assisted versus conventional total knee arthroplasty].

    PubMed

    Li, Xiaohui; Yu, Jianhua; Gong, Yuekun; Ren, Kaijing; Liu, Jun

    2015-04-21

    To assess the early postoperative clinical and radiographic outcomes after navigation-assisted or standard instrumentation total knee arthroplasty (TKA). From August 2007 to May 2008, 60 KSS-A type patients underwent 67 primary TKA operations by the same surgical team. Twenty-two operations were performed with the Image-free navigation system with an average age of 64.5 years while the remaining 45 underwent conventional manual procedures with an average age of 66 years. Their preoperative demographic and functional data had no statistical differences (P>0.05). The operative duration, blood loss volume and hospitalization days were compared for two groups. And radiographic data included coronal femoral component angle, coronal tibial component angle, sagittal femoral component angle, sagittal tibial component angle and coronal tibiofemoral angle after one month. And functional assessment scores were evaluated at 1, 3 and 6 months postoperatively. Operative duration was significantly longer for computer navigation (P<0.05). The average blood loss volume was 555.26 ml in computer navigation group and 647.56 ml in conventional manual method group (P<0.05). And hospitalization stay was shorter in computer navigation group than that in conventional method group (7.74 vs 8.68 days) (P=0.04). The alignment deviation was better in computer-assisted group than that in conventional manual method group (P<0.05). The percentage of patients with a coronal tibiofemoral angle within ±3 of ideal value was 95.45% for computer-assisted mini-invasive TKA group and 80% for conventional TKA group (P=0.003). The Knee Society Clinical Rating Score was higher in computer-assisted group than that in conventional manual method group at 1 and 3 montha post-operation. However, no statistical inter-group difference existed at 6 months post-operation. Navigation allows a surgeon to precisely implant the components for TKA. And it offers faster functional recovery and shorter hospitalization stay. At 6 months post-operation, there is no statistical inter-group difference in KSS scores.

  13. Review and evaluation of recent developments in melic inlet dynamic flow distortion prediction and computer program documentation and user's manual estimating maximum instantaneous inlet flow distortion from steady-state total pressure measurements with full, limited, or no dynamic data

    NASA Technical Reports Server (NTRS)

    Schweikhard, W. G.; Dennon, S. R.

    1986-01-01

    A review of the Melick method of inlet flow dynamic distortion prediction by statistical means is provided. These developments include the general Melick approach with full dynamic measurements, a limited dynamic measurement approach, and a turbulence modelling approach which requires no dynamic rms pressure fluctuation measurements. These modifications are evaluated by comparing predicted and measured peak instantaneous distortion levels from provisional inlet data sets. A nonlinear mean-line following vortex model is proposed and evaluated as a potential criterion for improving the peak instantaneous distortion map generated from the conventional linear vortex of the Melick method. The model is simplified to a series of linear vortex segments which lay along the mean line. Maps generated with this new approach are compared with conventionally generated maps, as well as measured peak instantaneous maps. Inlet data sets include subsonic, transonic, and supersonic inlets under various flight conditions.

  14. An analytical fuzzy-based approach to ?-gain optimal control of input-affine nonlinear systems using Newton-type algorithm

    NASA Astrophysics Data System (ADS)

    Milic, Vladimir; Kasac, Josip; Novakovic, Branko

    2015-10-01

    This paper is concerned with ?-gain optimisation of input-affine nonlinear systems controlled by analytic fuzzy logic system. Unlike the conventional fuzzy-based strategies, the non-conventional analytic fuzzy control method does not require an explicit fuzzy rule base. As the first contribution of this paper, we prove, by using the Stone-Weierstrass theorem, that the proposed fuzzy system without rule base is universal approximator. The second contribution of this paper is an algorithm for solving a finite-horizon minimax problem for ?-gain optimisation. The proposed algorithm consists of recursive chain rule for first- and second-order derivatives, Newton's method, multi-step Adams method and automatic differentiation. Finally, the results of this paper are evaluated on a second-order nonlinear system.

  15. [Selection of risk and diagnosis in diabetic polyneuropathy. Validation of method of new systems].

    PubMed

    Jurado, Jerónimo; Caula, Jacinto; Pou i Torelló, Josep Maria

    2006-06-30

    In a previous study we developed a specific algorithm, the polyneuropathy selection method (PSM) with 4 parameters (age, HDL-C, HbA1c, and retinopathy), to select patients at risk of diabetic polyneuropathy (DPN). We also developed a simplified method for DPN diagnosis: outpatient polyneuropathy diagnosis (OPD), with 4 variables (symptoms and 3 objective tests). To confirm the validity of conventional tests for DPN diagnosis; to validate the discriminatory power of the PSM and the diagnostic value of OPD by evaluating their relationship to electrodiagnosis studies and objective clinical neurological assessment; and to evaluate the correlation of DPN and pro-inflammatory status. Cross-sectional, crossed association for PSM validation. Paired samples for OPD validation. Primary care in 3 counties. Random sample of 75 subjects from the type-2 diabetes census for PSM evaluation. Thirty DPN patients and 30 non-DPN patients (from 2 DM2 sub-groups in our earlier study) for OPD evaluation. The gold standard for DPN diagnosis will be studied by means of a clinical neurological study (symptoms, physical examination, and sensitivity tests) and electrodiagnosis studies (sensitivity and motor EMG). Risks of neuropathy, macroangiopathy and pro-inflammatory status (PCR, TNF soluble fraction and total TGF-beta1) will be studied in every subject. Electrodiagnosis studies should confirm the validity of conventional tests for DPN diagnosis. PSM and OPD will be valid methods for selecting patients at risk and diagnosing DPN. There will be a significant relationship between DPN and pro-inflammatory tests.

  16. Evaluation of Cone Penetrometer Testing (CPT) for Use with Transportation Projects Phase 1

    DOT National Transportation Integrated Search

    2008-07-01

    The ODOT Office of Geotechnical Engineering (OGE) currently uses conventional drilling methods (e.g., hollow stem auger, solid stem auger) to perform subsurface investigations in unconsolidated materials. These techniques have been used for decades a...

  17. Development and In Vitro Bioactivity Profiling of Alternative Sustainable Nanomaterials

    EPA Science Inventory

    Sustainable, environmentally benign nanomaterials (NMs) are being designed as alternatives based on functionality to conventional metal-based nanomaterials (NMs) in order to minimize potential risk to human health and the environment. Development of rapid methods to evaluate the ...

  18. Evaluation of cone penetration testing (CPT) for use with transportation projects : executive summary report.

    DOT National Transportation Integrated Search

    2011-04-01

    The ODOT Office of Geotechnical : Engineering (OGE) currently uses : conventional drilling methods (e.g., hollow : stem auger, solid stem auger) to perform : subsurface investigations in soil. These : techniques have been used for decades and : have ...

  19. Comparison of conventional in vitro fertilisation and intracytoplasmic sperm injection outcomes in patients with moderate oligoasthenozoospermia.

    PubMed

    Shuai, H-L; Ye, Q; Huang, Y-H; Xie, B-G

    2015-06-01

    The method of choice for assisted reproductive technology treatment in vitro fertilisation (IVF) or intracytoplasmic sperm injection (ICSI) is usually based on the evaluation of male infertility factors. Decisions for couples with moderate oligoasthenozoospermia (OA) are often empirical because uniform treatment criteria are lacking. This study aimed to evaluate the effect of patients with moderate OA treated with conventional IVF and ICSI. A total of 199 couples with moderate OA undergoing their first IVF/ICSI cycle were included in the study. The patients were divided into two groups according to the type of insemination: conventional IVF group (n = 97) and ICSI group (n = 102). All patients were randomised to be inseminated either by conventional IVF or ICSI. The fertilisation rate, embryo quality, implantation rate and clinical pregnancy rate were examined. No differences in the fertilisation, implantation and pregnancy rates were observed between conventional IVF and ICSI groups (P > 0.05). However, the number of good-quality embryos was significantly higher in the ICSI group than in the IVF group (P < 0.05). Couples with moderate OA did not influence on the overall clinical outcomes between IVF and ICSI treatments, and a negative influence by ICSI on blastocyst development was not confirmed. © 2014 Blackwell Verlag GmbH.

  20. Complementary and Alternative Approaches to Pain Relief During Labor

    PubMed Central

    Theau-Yonneau, Anne

    2007-01-01

    This review evaluated the effect of complementary and alternative medicine on pain during labor with conventional scientific methods using electronic data bases through 2006 were used. Only randomized controlled trials with outcome measures for labor pain were kept for the conclusions. Many studies did not meet the scientific inclusion criteria. According to the randomized control trials, we conclude that for the decrease of labor pain and/or reduction of the need for conventional analgesic methods: (i) There is an efficacy found for acupressure and sterile water blocks. (ii) Most results favored some efficacy for acupuncture and hydrotherapy. (iii) Studies for other complementary or alternative therapies for labor pain control have not shown their effectiveness. PMID:18227907

  1. Influence of local anaesthesia on the quality of class II glass ionomer restorations.

    PubMed

    Van de Hoef, Nanda; Van Amerongen, Evert

    2007-07-01

    To investigate the influence of local anaesthesia on the quality of class II glass ionomer restorations with discomfort as cofactor. The study population consisted of 6- to 7-year-old schoolchildren in Paramaribo and its environs. To be included, each child needed to have a proximally situated cavity in a primary molar that was accessible to hand instruments and where no pulp exposure was expected. They were randomly divided into four treatment groups: conventional method with and without local anaesthesia and atraumatic restorative treatment method (ART) with and without local anaesthesia. The restoration quality was scored using the evaluation criteria for ART restorations (successful if restoration is correct or has a minor defect and fails if defects are larger than 0.5 mm, if secondary caries is observed, if the restoration is fractured, partly or totally lost or if the pulp is involved) at 6 and 30 months after treatment. The extent of discomfort was registered by assessing the behaviour (modified Venham score) and observing the heart rate during treatment. For this study 153 children were treated with hand instruments (ART) and 146 children with rotary instruments (conventional method). A total of 198 restorations were evaluated during follow-up periods. There were no significant differences in patient discomfort between the ART and the conventional group and between the anaesthesia and the non-anaesthesia group. The conventional restorations demonstrated significantly higher success rates than ART restorations after 6 (P = 0.001) and 30 months (P = 0.032). There were no significant differences in success rate between the anaesthesia and the non-anaesthesia group. Local anaesthesia has no influence on discomfort during treatment. Furthermore, discomfort during treatment does not affect the success rate of restorations.

  2. Intrapartum ultrasound: A useful method for evaluating labor progress and predicting operative vaginal delivery

    PubMed Central

    Ahn, Ki Hoon

    2014-01-01

    The last step of a successful pregnancy is the safe delivery of the fetus. An important question is if the delivery should vaginal or operative. In addition to the use of conventional antenatal ultrasound, the use of intrapartum ultrasound to evaluate fetal head station, position, cervical ripening, and placental separation is promising. This review evaluates and summarizes the usefulness of intrapartum ultrasound for the evaluation of labor progress and predicting successful operative vaginal delivery. PMID:25469329

  3. Usefulness of warm water and oil assistance in colonoscopy by trainees.

    PubMed

    Park, Sung Chul; Keum, Bora; Kim, Eun Sun; Jung, Eun Suk; Lee, Sehe Dong; Park, Sanghoon; Seo, Yeon Seok; Kim, Yong Sik; Jeen, Yoon Tae; Chun, Hoon Jai; Um, Soon Ho; Kim, Chang Duck; Ryu, Ho Sang

    2010-10-01

    Success rate of cecal intubation, endoscopist's difficulty, and procedure-related patient pain are still problems for beginners performing colonoscopy. New methods to aid colonoscopic insertion such as warm water instillation and oil lubrication have been proposed. The aim of this study is to evaluate the feasibility of using warm water or oil in colonoscopy. Colonoscopy was performed in 117 unsedated patients by three endoscopists-in-training. Patients were randomly allocated to three groups, using a conventional method with administration of antispasmodics, warm water instillation, and oil lubrication, respectively. Success rate of total intubation within time limit (15 min), cecal intubation time, degree of endoscopist's difficulty, and level of patient discomfort were compared among the three groups. Cecal intubation time was shorter in the warm water group than in the conventional and oil groups. Degree of procedural difficulty was lower in the warm water group, and patient pain score was higher in the oil lubrication group, compared with the other groups. However, there was no significant difference in success rate of intubation within time limit among the three groups. The warm water method is a simple, safe, and feasible method for beginners. Oil lubrication may not be a useful method compared with conventional and warm water method.

  4. Regression trees for predicting mortality in patients with cardiovascular disease: What improvement is achieved by using ensemble-based methods?

    PubMed Central

    Austin, Peter C; Lee, Douglas S; Steyerberg, Ewout W; Tu, Jack V

    2012-01-01

    In biomedical research, the logistic regression model is the most commonly used method for predicting the probability of a binary outcome. While many clinical researchers have expressed an enthusiasm for regression trees, this method may have limited accuracy for predicting health outcomes. We aimed to evaluate the improvement that is achieved by using ensemble-based methods, including bootstrap aggregation (bagging) of regression trees, random forests, and boosted regression trees. We analyzed 30-day mortality in two large cohorts of patients hospitalized with either acute myocardial infarction (N = 16,230) or congestive heart failure (N = 15,848) in two distinct eras (1999–2001 and 2004–2005). We found that both the in-sample and out-of-sample prediction of ensemble methods offered substantial improvement in predicting cardiovascular mortality compared to conventional regression trees. However, conventional logistic regression models that incorporated restricted cubic smoothing splines had even better performance. We conclude that ensemble methods from the data mining and machine learning literature increase the predictive performance of regression trees, but may not lead to clear advantages over conventional logistic regression models for predicting short-term mortality in population-based samples of subjects with cardiovascular disease. PMID:22777999

  5. Use of microresistivity from the dipmeter to improve formation evaluation in thin sands, Northeast Kalimantan, Indonesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sallee, J.E.; Wood, B.R.

    1984-09-01

    Estimation of reserves in lenticular reservoirs consisting of many thin-bedded sand/shale sequences is complicated by an overly pessimistic evaluation of sand count and hydrocarbon in place when conventional log interpretation techniques are used. It is probable that thin clean sand lenses have connected permeability. Their contribution to production should be considered in the estimation of reserves. An approach has been devised to improve the evaluation of thin clean sands by introducing accurate bed boundaries between sand and shale laminae as identified clearly on the dipmeter microresistivity curve processing presentation (GEODIP). Dipmeter data are integrated into conventional computer log analyses tomore » yield more realistic estimates of porosity and hydrocarbon saturation throughout the reservoir. The method and the results attained to date are described.« less

  6. Natural air leak test without submergence for spontaneous pneumothorax.

    PubMed

    Uramoto, Hidetaka; Tanaka, Fumihiro

    2011-12-24

    Postoperative air leaks are frequent complications after surgery for a spontaneous pneumothorax (SP). We herein describe a new method to test for air leaks by using a transparent film and thoracic tube in a closed system. Between 2005 and 2010, 35 patients underwent a novel method for evaluating air leaks without submergence, and their clinical records were retrospectively reviewed. The data on patient characteristics, surgical details, and perioperative outcomes were analyzed. The differences in the clinical background and intraoperative factors did not reach a statistically significant level between the new and classical methods. The incidence of recurrence was also equivalent to the standard method. However, the length of the operation and drainage periods were significantly shorter in patients evaluated using the new method than the conventional method. Further, no postoperative complications were observed in patients evaluated using the new method. This simple technique is satisfactorily effective and does not result in any complications.

  7. Methods for evaluating changes in skin condition due to the effects of antimicrobial hand cleansers: two studies comparing a new waterless chlorhexidine gluconate/ethanol-emollient antiseptic preparation with a conventional water-applied product.

    PubMed

    Grove, G L; Zerweck, C R; Heilman, J M; Pyrek, J D

    2001-12-01

    Hand-cleansing products that are milder to the skin of health care personnel are being developed, but the available methodologies to appropriately evaluate these products and quantify differences are not generally being applied in well-controlled studies. Two randomized, blinded, bilateral comparison studies evaluated skin condition during use of 2 antiseptic hand preparation products: a new 1% chlorhexidine gluconate (CHG)/61% wt/wt ethanol antiseptic hand preparation in a unique emollient system for waterless/brushless application and a conventional 4% CHG antimicrobial product that is applied with water and a scrub brush. Trained technicians applied treatments 6 times (for a surgical scrub study) or 24 times (for a personnel handwash study) daily to the hands of healthy volunteers during 5 days of controlled washing. An expert grader evaluated skin for dryness, erythema, and roughness. Subjects completed a self-assessment questionnaire on skin condition. Transepidermal water loss was measured by an evaporimeter, and the skin surface hydration level was measured by an electrical conductance meter. Fifty-eight subjects were enrolled in the 2 studies and received both treatments. In general, skin treated with the waterless CHG/ethanol product scored significantly (P <.004) better on evaluations of visual dryness and erythema and showed greater improvement in the level of hydration (P <.003). In the health care personnel handwash study, transepidermal water loss was less than that for skin treated with the conventional CHG product (P <.002). Subject assessments showed similar results (total score, P <.007). All 3 approaches of expert grader evaluation, subject assessment, and instrumentation were in concordance, demonstrating that the waterless CHG/ethanol product was gentler to skin than the conventional CHG product.

  8. Comparison of Arterial Spin-labeling Perfusion Images at Different Spatial Normalization Methods Based on Voxel-based Statistical Analysis.

    PubMed

    Tani, Kazuki; Mio, Motohira; Toyofuku, Tatsuo; Kato, Shinichi; Masumoto, Tomoya; Ijichi, Tetsuya; Matsushima, Masatoshi; Morimoto, Shoichi; Hirata, Takumi

    2017-01-01

    Spatial normalization is a significant image pre-processing operation in statistical parametric mapping (SPM) analysis. The purpose of this study was to clarify the optimal method of spatial normalization for improving diagnostic accuracy in SPM analysis of arterial spin-labeling (ASL) perfusion images. We evaluated the SPM results of five spatial normalization methods obtained by comparing patients with Alzheimer's disease or normal pressure hydrocephalus complicated with dementia and cognitively healthy subjects. We used the following methods: 3DT1-conventional based on spatial normalization using anatomical images; 3DT1-DARTEL based on spatial normalization with DARTEL using anatomical images; 3DT1-conventional template and 3DT1-DARTEL template, created by averaging cognitively healthy subjects spatially normalized using the above methods; and ASL-DARTEL template created by averaging cognitively healthy subjects spatially normalized with DARTEL using ASL images only. Our results showed that ASL-DARTEL template was small compared with the other two templates. Our SPM results obtained with ASL-DARTEL template method were inaccurate. Also, there were no significant differences between 3DT1-conventional and 3DT1-DARTEL template methods. In contrast, the 3DT1-DARTEL method showed higher detection sensitivity, and precise anatomical location. Our SPM results suggest that we should perform spatial normalization with DARTEL using anatomical images.

  9. A fast and sensitive method for evaluating nuclides migration characteristics in rock medium by using micro-channel reactor concept

    NASA Astrophysics Data System (ADS)

    Okuyama, Keita; Sasahira, Akira; Noshita, Kenji; Yoshida, Takuma; Kato, Kazuyuki; Nagasaki, Shinya; Ohe, Toshiaki

    Experimental effort to evaluate the barrier performance of geologic disposal requires relatively long testing periods and chemically stable conditions. We have developed a new technique, the micro mock-up method, to present a fast and sensitive method to measure both nuclide diffusivity and sorption coefficient within a day to overcome such disadvantage of the conventional method. In this method, a Teflon plate having a micro channel (10-200 μm depth, 2, 4 mm width) is placed just beneath the rock sample plate, radionuclide solution is injected into the channel with constant rate. The breakthrough curve is being measured until a steady state. The outlet flux in the steady state however does not meet the inlet flux because of the matrix diffusion into the rock body. This inlet-outlet difference is simply related to the effective diffusion coefficient ( De) and the distribution coefficient ( Kd) of rock sample. Then, we adopt a fitting procedure to speculate Kd and De values by comparing the observation to the theoretical curve of the two-dimensional diffusion-advection equation. In the present study, we measured De of 3H by using both the micro mock-up method and the conventional through-diffusion method for comparison. The obtained values of De by two different ways for granite sample (Inada area of Japan) were identical: 1.0 × 10 -11 and 9.0 × 10 -12 m 2/s but the testing period was much different: 10 h and 3 days, respectively. We also measured the breakthrough curve of 85Sr and the resulting Kd and De agreed well to the previous study obtained by the batch sorption experiments with crushed samples. The experimental evidence and the above advantages reveal that the micro mock-up method based on the microreactor concept is powerful and much advantageous when compared to the conventional method.

  10. Credit Risk Evaluation of Power Market Players with Random Forest

    NASA Astrophysics Data System (ADS)

    Umezawa, Yasushi; Mori, Hiroyuki

    A new method is proposed for credit risk evaluation in a power market. The credit risk evaluation is to measure the bankruptcy risk of the company. The power system liberalization results in new environment that puts emphasis on the profit maximization and the risk minimization. There is a high probability that the electricity transaction causes a risk between companies. So, power market players are concerned with the risk minimization. As a management strategy, a risk index is requested to evaluate the worth of the business partner. This paper proposes a new method for evaluating the credit risk with Random Forest (RF) that makes ensemble learning for the decision tree. RF is one of efficient data mining technique in clustering data and extracting relationship between input and output data. In addition, the method of generating pseudo-measurements is proposed to improve the performance of RF. The proposed method is successfully applied to real financial data of energy utilities in the power market. A comparison is made between the proposed and the conventional methods.

  11. Evaluation of Oregon's first hot mix asphalt recycling project : Woodburn, Oregon, 1977.

    DOT National Transportation Integrated Search

    1979-03-01

    Pavement recycling has been suggested as a viable alternative to more conventional methods of pavement rehabilitation as a means of offsetting some of the problems resulting from spiraling energy costs and shortages of raw materials. This paper prese...

  12. Erosion prevention during highway construction by the use of sprayed on chemicals.

    DOT National Transportation Integrated Search

    1972-01-01

    The purpose of this study was to evaluate the erosion inhibiting potential of nine commercial spray on plastic chemicals. All chemicals were also compared with the conventional method of straw tacked with an asphalt emulsion, and with untreated soil....

  13. A pump monitoring approach to irrigation pumping plant testing

    USDA-ARS?s Scientific Manuscript database

    The conventional approach for evaluating irrigation pumping plant performance has been an instantaneous spot measurement approach. Using this method, the tester measures the necessary work and energy use parameters to determine overall pumping plant performance. The primary limitation of this appr...

  14. Line-width roughness of advanced semiconductor features by using FIB and planar-TEM as reference metrology

    NASA Astrophysics Data System (ADS)

    Takamasu, Kiyoshi; Takahashi, Satoru; Kawada, Hiroki; Ikota, Masami

    2018-03-01

    LER (Line Edge Roughness) and LWR (Line Width Roughness) of the semiconductor device are an important evaluation scale of the performance of the device. Conventionally, LER and LWR is evaluated from CD-SEM (Critical Dimension Scanning Electron Microscope) images. However, CD-SEM measurement has a problem that high frequency random noise is large, and resolution is not sufficiently high. For random noise of CD-SEM measurement, some techniques are proposed. In these methods, it is necessary to set parameters for model and processing, and it is necessary to verify the correctness of these parameters using reference metrology. We have already proposed a novel reference metrology using FIB (Focused Ion Beam) process and planar-TEM (Transmission Electron Microscope) method. In this study, we applied the proposed method to three new samples such as SAQP (Self-Aligned Quadruple Patterning) FinFET device, EUV (Extreme Ultraviolet Lithography) conventional resist, and EUV new material resist. LWR and PSD (Power Spectral Density) of LWR are calculated from the edge positions on planar-TEM images. We confirmed that LWR and PSD of LWR can be measured with high accuracy and evaluated the difference by the proposed method. Furthermore, from comparisons with PSD of the same sample by CD-SEM, the validity of measurement of PSD and LWR by CD-SEM can be verified.

  15. Predicting gaseous reaction rates of short chain chlorinated paraffins with ·OH: overcoming the difficulty in experimental determination.

    PubMed

    Li, Chao; Xie, Hong-Bin; Chen, Jingwen; Yang, Xianhai; Zhang, Yifei; Qiao, Xianliang

    2014-12-02

    Short chain chlorinated paraffins (SCCPs) are under evaluation for inclusion in the Stockholm Convention on persistent organic pollutants. However, information on their reaction rate constants with gaseous ·OH (kOH) is unavailable, limiting the evaluation of their persistence in the atmosphere. Experimental determination of kOH is confined by the unavailability of authentic chemical standards for some SCCP congeners. In this study, we evaluated and selected density functional theory (DFT) methods to predict kOH of SCCPs, by comparing the experimental kOH values of six polychlorinated alkanes (PCAs) with those calculated by the different theoretical methods. We found that the M06-2X/6-311+G(3df,2pd)//B3LYP/6-311 +G(d,p) method is time-effective and can be used to predict kOH of PCAs. Moreover, based on the calculated kOH of nine SCCPs and available experimental kOH values of 22 PCAs with low carbon chain, a quantitative structure-activity relationship (QSAR) model was developed. The molecular structural characteristics determining the ·OH reaction rate were discussed. logkOH was found to negatively correlate with the percentage of chlorine substitutions (Cl%). The DFT calculation method and the QSAR model are important alternatives to the conventional experimental determination of kOH for SCCPs, and are prospective in predicting their persistence in the atmosphere.

  16. Comparison the Marginal and Internal Fit of Metal Copings Cast from Wax Patterns Fabricated by CAD/CAM and Conventional Wax up Techniques.

    PubMed

    Vojdani, M; Torabi, K; Farjood, E; Khaledi, Aar

    2013-09-01

    Metal-ceramic crowns are most commonly used as the complete coverage restorations in clinical daily use. Disadvantages of conventional hand-made wax-patterns introduce some alternative ways by means of CAD/CAM technologies. This study compares the marginal and internal fit of copings cast from CAD/CAM and conventional fabricated wax-patterns. Twenty-four standardized brass dies were prepared and randomly divided into 2 groups according to the wax-patterns fabrication method (CAD/CAM technique and conventional method) (n=12). All the wax-patterns were fabricated in a standard fashion by means of contour, thickness and internal relief (M1-M12: representative of CAD/CAM group, C1-C12: representative of conventional group). CAD/CAM milling machine (Cori TEC 340i; imes-icore GmbH, Eiterfeld, Germany) was used to fabricate the CAD/CAM group wax-patterns. The copings cast from 24 wax-patterns were cemented to the corresponding dies. For all the coping-die assemblies cross-sectional technique was used to evaluate the marginal and internal fit at 15 points. The Student's t- test was used for statistical analysis (α=0.05). The overall mean (SD) for absolute marginal discrepancy (AMD) was 254.46 (25.10) um for CAD/CAM group and 88.08(10.67) um for conventional group (control). The overall mean of internal gap total (IGT) was 110.77(5.92) um for CAD/CAM group and 76.90 (10.17) um for conventional group. The Student's t-test revealed significant differences between 2 groups. Marginal and internal gaps were found to be significantly higher at all measured areas in CAD/CAM group than conventional group (p< 0.001). Within limitations of this study, conventional method of wax-pattern fabrication produced copings with significantly better marginal and internal fit than CAD/CAM (machine-milled) technique. All the factors for 2 groups were standardized except wax pattern fabrication technique, therefore, only the conventional group results in copings with clinically acceptable margins of less than 120um.

  17. A Unified Fisher's Ratio Learning Method for Spatial Filter Optimization.

    PubMed

    Li, Xinyang; Guan, Cuntai; Zhang, Haihong; Ang, Kai Keng

    To detect the mental task of interest, spatial filtering has been widely used to enhance the spatial resolution of electroencephalography (EEG). However, the effectiveness of spatial filtering is undermined due to the significant nonstationarity of EEG. Based on regularization, most of the conventional stationary spatial filter design methods address the nonstationarity at the cost of the interclass discrimination. Moreover, spatial filter optimization is inconsistent with feature extraction when EEG covariance matrices could not be jointly diagonalized due to the regularization. In this paper, we propose a novel framework for a spatial filter design. With Fisher's ratio in feature space directly used as the objective function, the spatial filter optimization is unified with feature extraction. Given its ratio form, the selection of the regularization parameter could be avoided. We evaluate the proposed method on a binary motor imagery data set of 16 subjects, who performed the calibration and test sessions on different days. The experimental results show that the proposed method yields improvement in classification performance for both single broadband and filter bank settings compared with conventional nonunified methods. We also provide a systematic attempt to compare different objective functions in modeling data nonstationarity with simulation studies.To detect the mental task of interest, spatial filtering has been widely used to enhance the spatial resolution of electroencephalography (EEG). However, the effectiveness of spatial filtering is undermined due to the significant nonstationarity of EEG. Based on regularization, most of the conventional stationary spatial filter design methods address the nonstationarity at the cost of the interclass discrimination. Moreover, spatial filter optimization is inconsistent with feature extraction when EEG covariance matrices could not be jointly diagonalized due to the regularization. In this paper, we propose a novel framework for a spatial filter design. With Fisher's ratio in feature space directly used as the objective function, the spatial filter optimization is unified with feature extraction. Given its ratio form, the selection of the regularization parameter could be avoided. We evaluate the proposed method on a binary motor imagery data set of 16 subjects, who performed the calibration and test sessions on different days. The experimental results show that the proposed method yields improvement in classification performance for both single broadband and filter bank settings compared with conventional nonunified methods. We also provide a systematic attempt to compare different objective functions in modeling data nonstationarity with simulation studies.

  18. Video-based teleradiology for intraosseous lesions. A receiver operating characteristic analysis.

    PubMed

    Tyndall, D A; Boyd, K S; Matteson, S R; Dove, S B

    1995-11-01

    Immediate access to off-site expert diagnostic consultants regarding unusual radiographic findings or radiographic quality assurance issues could be a current problem for private dental practitioners. Teleradiology, a system for transmitting radiographic images, offers a potential solution to this problem. Although much research has been done to evaluate feasibility and utilization of teleradiology systems in medical imaging, little research on dental applications has been performed. In this investigation 47 panoramic films with an equal distribution of images with intraosseous jaw lesions and no disease were viewed by a panel of observers with teleradiology and conventional viewing methods. The teleradiology system consisted of an analog video-based system simulating remote radiographic consultation between a general dentist and a dental imaging specialist. Conventional viewing consisted of traditional viewbox methods. Observers were asked to identify the presence or absence of 24 intraosseous lesions and to determine their locations. No statistically significant differences in modalities or observers were identified between methods at the 0.05 level. The results indicate that viewing intraosseous lesions of video-based panoramic images is equal to conventional light box viewing.

  19. High throughput screening of active pharmaceutical ingredients by UPLC.

    PubMed

    Al-Sayah, Mohammad A; Rizos, Panagiota; Antonucci, Vincent; Wu, Naijun

    2008-07-01

    Ultra performance LC (UPLC) was evaluated as an efficient screening approach to facilitate method development for drug candidates. Three stationary phases were screened: C-18, phenyl, and Shield RP 18 with column dimensions of 150 mm x 2.1 mm, 1.7 microm, which should theoretically generate 35,000 plates or 175% of the typical column plate count of a conventional 250 mm x 4.6 mm, 5 microm particle column. Thirteen different active pharmaceutical ingredients (APIs) were screened using this column set with a standardized mobile-phase gradient. The UPLC method selectivity results were compared to those obtained for these compounds via methods developed through laborious trial and error screening experiments using numerous conventional HPLC mobile and stationary phases. Peak capacity was compared for columns packed with 5 microm particles and columns packed with 1.7 microm particles. The impurities screened by UPLC were confirmed by LC/MS. The results demonstrate that simple, high efficiency UPLC gradients are a feasible and productive alternative to more conventional multiparametric chromatographic screening approaches for many compounds in the early stages of drug development.

  20. Simplicity, safety, and acceptability of insulin pen use versus the conventional vial/syringe device in patients with type 1 and type 2 diabetes mellitus in Lebanon

    PubMed Central

    Ramadan, Wijdan H; Khreis, Noura A; Kabbara, Wissam K

    2015-01-01

    Background The aim of the study was to evaluate the simplicity, safety, patients’ preference, and convenience of the administration of insulin using the pen device versus the conventional vial/syringe in patients with diabetes. Methods This observational study was conducted in multiple community pharmacies in Lebanon. The investigators interviewed patients with diabetes using an insulin pen or conventional vial/syringe. A total of 74 questionnaires were filled over a period of 6 months. Answers were entered into the Statistical Package for Social Sciences (SPSS) software and Excel spreadsheet. t-test, logistic regression analysis, and correlation analysis were used in order to analyze the results. Results A higher percentage of patients from the insulin pen users group (95.2%) found the method easy to use as compared to only 46.7% of the insulin conventional users group (P 0.001, relative risk [RR]: 2.041, 95% confidence interval [CI]: 1.178–3.535). Moreover, 61.9% and 26.7% of pen users and conventional users, respectively, could read the scale easily (P 0.037, RR 2.321, 95% CI: 0.940–5.731), while 85.7% of pen users found it more convenient shifting to pen and 86.7% of the conventional users would want to shift to pen if it had the same cost. Pain perception was statistically different between the groups. A much higher percentage (76.2%) of pen users showed no pain during injection compared to only 26.7% of conventional users (P 0.003, RR 2.857, 95% CI: 1.194–6.838). Conclusion The insulin pen was significantly much easier to use and less painful than the conventional vial/syringe. Proper education on the methods of administration/storage and disposal of needles/syringes is needed in both groups. PMID:25848231

  1. Comparison of the Microbiological Quality and Safety between Conventional and Organic Vegetables Sold in Malaysia

    PubMed Central

    Kuan, Chee-Hao; Rukayadi, Yaya; Ahmad, Siti H.; Wan Mohamed Radzi, Che W. J.; Thung, Tze-Young; Premarathne, Jayasekara M. K. J. K.; Chang, Wei-San; Loo, Yuet-Ying; Tan, Chia-Wanq; Ramzi, Othman B.; Mohd Fadzil, Siti N.; Kuan, Chee-Sian; Yeo, Siok-Koon; Nishibuchi, Mitsuaki; Radu, Son

    2017-01-01

    Given the remarkable increase of public interest in organic food products, it is indeed critical to evaluate the microbiological risk associated with consumption of fresh organic produce. Organic farming practices including the use of animal manures may increase the risk of microbiological contamination as manure can act as a vehicle for transmission of foodborne pathogens. This study aimed to determine and compare the microbiological status between organic and conventional fresh produce at the retail level in Malaysia. A total of 152 organic and conventional vegetables were purchased at retail markets in Malaysia. Samples were analyzed for mesophilic aerobic bacteria, yeasts and molds, and total coliforms using conventional microbiological methods. Combination methods of most probable number-multiplex polymerase chain reaction (MPN-mPCR) were used to detect and quantify foodborne pathogens, including Escherichia coli O157:H7, Shiga toxin-producing E. coli (STEC), Listeria monocytogenes, Salmonella Typhimurium, and Salmonella Enteritidis. Results indicated that most types of organic and conventional vegetables possessed similar microbial count (P > 0.05) of mesophilic aerobic bacteria, yeasts and molds, and total coliforms. E. coli O157:H7 and S. Typhimurium were not detected in any sample analyzed in this study. Among the 152 samples tested, only the conventional lettuce and organic carrot were tested positive for STEC and S. Enteritidis, respectively. L. monocytogenes were more frequently detected in both organic (9.1%) and conventional vegetables (2.7%) as compared to E. coli O157:H7, S. Typhimurium, and S. Enteritidis. Overall, no trend was shown that either organically or conventionally grown vegetables have posed greater microbiological risks. These findings indicated that one particular type of farming practices would not affect the microbiological profiles of fresh produce. Therefore, regardless of farming methods, all vegetables should be subjected to appropriate post-harvest handling practices from farm to fork to ensure the quality and safety of the fresh produce. PMID:28824567

  2. Comparison of the Microbiological Quality and Safety between Conventional and Organic Vegetables Sold in Malaysia.

    PubMed

    Kuan, Chee-Hao; Rukayadi, Yaya; Ahmad, Siti H; Wan Mohamed Radzi, Che W J; Thung, Tze-Young; Premarathne, Jayasekara M K J K; Chang, Wei-San; Loo, Yuet-Ying; Tan, Chia-Wanq; Ramzi, Othman B; Mohd Fadzil, Siti N; Kuan, Chee-Sian; Yeo, Siok-Koon; Nishibuchi, Mitsuaki; Radu, Son

    2017-01-01

    Given the remarkable increase of public interest in organic food products, it is indeed critical to evaluate the microbiological risk associated with consumption of fresh organic produce. Organic farming practices including the use of animal manures may increase the risk of microbiological contamination as manure can act as a vehicle for transmission of foodborne pathogens. This study aimed to determine and compare the microbiological status between organic and conventional fresh produce at the retail level in Malaysia. A total of 152 organic and conventional vegetables were purchased at retail markets in Malaysia. Samples were analyzed for mesophilic aerobic bacteria, yeasts and molds, and total coliforms using conventional microbiological methods. Combination methods of most probable number-multiplex polymerase chain reaction (MPN-mPCR) were used to detect and quantify foodborne pathogens, including Escherichia coli O157:H7, Shiga toxin-producing E. coli (STEC), Listeria monocytogenes, Salmonella Typhimurium, and Salmonella Enteritidis. Results indicated that most types of organic and conventional vegetables possessed similar microbial count ( P > 0.05) of mesophilic aerobic bacteria, yeasts and molds, and total coliforms. E. coli O157:H7 and S . Typhimurium were not detected in any sample analyzed in this study. Among the 152 samples tested, only the conventional lettuce and organic carrot were tested positive for STEC and S . Enteritidis, respectively. L. monocytogenes were more frequently detected in both organic (9.1%) and conventional vegetables (2.7%) as compared to E. coli O157:H7, S . Typhimurium, and S . Enteritidis. Overall, no trend was shown that either organically or conventionally grown vegetables have posed greater microbiological risks. These findings indicated that one particular type of farming practices would not affect the microbiological profiles of fresh produce. Therefore, regardless of farming methods, all vegetables should be subjected to appropriate post-harvest handling practices from farm to fork to ensure the quality and safety of the fresh produce.

  3. Diagnostic utility of the cell block method versus the conventional smear study in pleural fluid cytology

    PubMed Central

    Shivakumarswamy, Udasimath; Arakeri, Surekha U; Karigowdar, Mahesh H; Yelikar, BR

    2012-01-01

    Background: The cytological examinations of serous effusions have been well-accepted, and a positive diagnosis is often considered as a definitive diagnosis. It helps in staging, prognosis and management of the patients in malignancies and also gives information about various inflammatory and non-inflammatory lesions. Diagnostic problems arise in everyday practice to differentiate reactive atypical mesothelial cells and malignant cells by the routine conventional smear (CS) method. Aims: To compare the morphological features of the CS method with those of the cell block (CB) method and also to assess the utility and sensitivity of the CB method in the cytodiagnosis of pleural effusions. Materials and Methods: The study was conducted in the cytology section of the Department of Pathology. Sixty pleural fluid samples were subjected to diagnostic evaluation for over a period of 20 months. Along with the conventional smears, cell blocks were prepared by using 10% alcohol–formalin as a fixative agent. Statistical analysis with the ‘z test’ was performed to identify the cellularity, using the CS and CB methods. Mc. Naemer's χ2test was used to identify the additional yield for malignancy by the CB method. Results: Cellularity and additional yield for malignancy was 15% more by the CB method. Conclusions: The CB method provides high cellularity, better architectural patterns, morphological features and an additional yield of malignant cells, and thereby, increases the sensitivity of the cytodiagnosis when compared with the CS method. PMID:22438610

  4. A GPU-based calculation using the three-dimensional FDTD method for electromagnetic field analysis.

    PubMed

    Nagaoka, Tomoaki; Watanabe, Soichi

    2010-01-01

    Numerical simulations with the numerical human model using the finite-difference time domain (FDTD) method have recently been performed frequently in a number of fields in biomedical engineering. However, the FDTD calculation runs too slowly. We focus, therefore, on general purpose programming on the graphics processing unit (GPGPU). The three-dimensional FDTD method was implemented on the GPU using Compute Unified Device Architecture (CUDA). In this study, we used the NVIDIA Tesla C1060 as a GPGPU board. The performance of the GPU is evaluated in comparison with the performance of a conventional CPU and a vector supercomputer. The results indicate that three-dimensional FDTD calculations using a GPU can significantly reduce run time in comparison with that using a conventional CPU, even a native GPU implementation of the three-dimensional FDTD method, while the GPU/CPU speed ratio varies with the calculation domain and thread block size.

  5. Tune Evaluation From Phased BPM Turn-By-Turn Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alexahin, Y.; Gianfelice-Wendt, E.; Marsh, W.

    2010-05-18

    In fast ramping synchrotrons like the Fermilab Booster the conventional methods of betatron tune evaluation from the turn-by-turn data may not work due to rapid changes of the tunes (sometimes in a course of a few dozens of turns) and a high level of noise. We propose a technique based on phasing of signals from a large number of BPMs which significantly increases the signal to noise ratio. Implementation of the method in the Fermilab Booster control system is described and some measurement results are presented.

  6. Evaluation of purity with its uncertainty value in high purity lead stick by conventional and electro-gravimetric methods

    PubMed Central

    2013-01-01

    Background A conventional gravimetry and electro-gravimetry study has been carried out for the precise and accurate purity determination of lead (Pb) in high purity lead stick and for preparation of reference standard. Reference materials are standards containing a known amount of an analyte and provide a reference value to determine unknown concentrations or to calibrate analytical instruments. A stock solution of approximate 2 kg has been prepared after dissolving approximate 2 g of Pb stick in 5% ultra pure nitric acid. From the stock solution five replicates of approximate 50 g have been taken for determination of purity by each method. The Pb has been determined as PbSO4 by conventional gravimetry, as PbO2 by electro gravimetry. The percentage purity of the metallic Pb was calculated accordingly from PbSO4 and PbO2. Results On the basis of experimental observations it has been concluded that by conventional gravimetry and electro-gravimetry the purity of Pb was found to be 99.98 ± 0.24 and 99.97 ± 0.27 g/100 g and on the basis of Pb purity the concentration of reference standard solutions were found to be 1000.88 ± 2.44 and 1000.81 ± 2.68 mg kg-1 respectively with 95% confidence level (k = 2). The uncertainty evaluation has also been carried out in Pb determination following EURACHEM/GUM guidelines. The final analytical results quantifying uncertainty fulfills this requirement and gives a measure of the confidence level of the concerned laboratory. Conclusions Gravimetry is the most reliable technique in comparison to titremetry and instrumental method and the results of gravimetry are directly traceable to SI unit. Gravimetric analysis, if methods are followed carefully, provides for exceedingly precise analysis. In classical gravimetry the major uncertainties are due to repeatability but in electro-gravimetry several other factors also affect the final results. PMID:23800080

  7. Evaluation of purity with its uncertainty value in high purity lead stick by conventional and electro-gravimetric methods.

    PubMed

    Singh, Nahar; Singh, Niranjan; Tripathy, S Swarupa; Soni, Daya; Singh, Khem; Gupta, Prabhat K

    2013-06-26

    A conventional gravimetry and electro-gravimetry study has been carried out for the precise and accurate purity determination of lead (Pb) in high purity lead stick and for preparation of reference standard. Reference materials are standards containing a known amount of an analyte and provide a reference value to determine unknown concentrations or to calibrate analytical instruments. A stock solution of approximate 2 kg has been prepared after dissolving approximate 2 g of Pb stick in 5% ultra pure nitric acid. From the stock solution five replicates of approximate 50 g have been taken for determination of purity by each method. The Pb has been determined as PbSO4 by conventional gravimetry, as PbO2 by electro gravimetry. The percentage purity of the metallic Pb was calculated accordingly from PbSO4 and PbO2. On the basis of experimental observations it has been concluded that by conventional gravimetry and electro-gravimetry the purity of Pb was found to be 99.98 ± 0.24 and 99.97 ± 0.27 g/100 g and on the basis of Pb purity the concentration of reference standard solutions were found to be 1000.88 ± 2.44 and 1000.81 ± 2.68 mg kg-1 respectively with 95% confidence level (k = 2). The uncertainty evaluation has also been carried out in Pb determination following EURACHEM/GUM guidelines. The final analytical results quantifying uncertainty fulfills this requirement and gives a measure of the confidence level of the concerned laboratory. Gravimetry is the most reliable technique in comparison to titremetry and instrumental method and the results of gravimetry are directly traceable to SI unit. Gravimetric analysis, if methods are followed carefully, provides for exceedingly precise analysis. In classical gravimetry the major uncertainties are due to repeatability but in electro-gravimetry several other factors also affect the final results.

  8. Pain Elimination during Injection with Newer Electronic Devices: A Comparative Evaluation in Children

    PubMed Central

    Saha, Sonali; Jaiswal, JN; Samadi, Firoza

    2014-01-01

    ABSTRACT Aim: The present study was taken up to clinically evaluate and compare effectiveness of transcutaneous electrical nerve stimulator (TENS) and comfort control syringe (CCS) in various pediatric dental procedures as an alternative to the conventional method of local anesthesia (LA) administration. Materials and methods: Ninety healthy children having at least one deciduous molar tooth indicated for extraction in either maxillary right or left quadrant in age group of 6 to 10 years were randomly divided into three equal groups having 30 subjects each. Group I: LA administration using conventional syringe, group II: LA administration using TENS along with the conventional syringe, group III: LA administration using CCS. After LA by the three techniques, pain, anxiety and heart rate were measured. Statistical analysis: The observations, thus, obtained were subjected to statistical analysis using analysis of variance (ANOVA), student t-test and paired t-test. Results: The mean pain score was maximum in group I followed by group II, while group III revealed the minimum pain, where LA was administered using CCS. Mean anxiety score was maximum in group I followed by group II, while group III revealed the minimum score. Mean heart rate was maximum in group I followed in descending order by groups II and III. Conclusion: The study supports the belief that CCS could be a viable alternative in comparison to the other two methods of LA delivery in children. How to cite this article: Bansal N, Saha S, Jaiswal JN, Samadi F. Pain Elimination during Injection with Newer Electronic Devices: A Comparative Evaluation in Children. Int J Clin Pediatr Dent 2014;7(2):71-76. PMID:25356003

  9. Two modified symplectic partitioned Runge-Kutta methods for solving the elastic wave equation

    NASA Astrophysics Data System (ADS)

    Su, Bo; Tuo, Xianguo; Xu, Ling

    2017-08-01

    Based on a modified strategy, two modified symplectic partitioned Runge-Kutta (PRK) methods are proposed for the temporal discretization of the elastic wave equation. The two symplectic schemes are similar in form but are different in nature. After the spatial discretization of the elastic wave equation, the ordinary Hamiltonian formulation for the elastic wave equation is presented. The PRK scheme is then applied for time integration. An additional term associated with spatial discretization is inserted into the different stages of the PRK scheme. Theoretical analyses are conducted to evaluate the numerical dispersion and stability of the two novel PRK methods. A finite difference method is used to approximate the spatial derivatives since the two schemes are independent of the spatial discretization technique used. The numerical solutions computed by the two new schemes are compared with those computed by a conventional symplectic PRK. The numerical results, which verify the new method, are superior to those generated by traditional conventional methods in seismic wave modeling.

  10. Design of a practical model-observer-based image quality assessment method for CT imaging systems

    NASA Astrophysics Data System (ADS)

    Tseng, Hsin-Wu; Fan, Jiahua; Cao, Guangzhi; Kupinski, Matthew A.; Sainath, Paavana

    2014-03-01

    The channelized Hotelling observer (CHO) is a powerful method for quantitative image quality evaluations of CT systems and their image reconstruction algorithms. It has recently been used to validate the dose reduction capability of iterative image-reconstruction algorithms implemented on CT imaging systems. The use of the CHO for routine and frequent system evaluations is desirable both for quality assurance evaluations as well as further system optimizations. The use of channels substantially reduces the amount of data required to achieve accurate estimates of observer performance. However, the number of scans required is still large even with the use of channels. This work explores different data reduction schemes and designs a new approach that requires only a few CT scans of a phantom. For this work, the leave-one-out likelihood (LOOL) method developed by Hoffbeck and Landgrebe is studied as an efficient method of estimating the covariance matrices needed to compute CHO performance. Three different kinds of approaches are included in the study: a conventional CHO estimation technique with a large sample size, a conventional technique with fewer samples, and the new LOOL-based approach with fewer samples. The mean value and standard deviation of area under ROC curve (AUC) is estimated by shuffle method. Both simulation and real data results indicate that an 80% data reduction can be achieved without loss of accuracy. This data reduction makes the proposed approach a practical tool for routine CT system assessment.

  11. A review on recent contribution of meshfree methods to structure and fracture mechanics applications.

    PubMed

    Daxini, S D; Prajapati, J M

    2014-01-01

    Meshfree methods are viewed as next generation computational techniques. With evident limitations of conventional grid based methods, like FEM, in dealing with problems of fracture mechanics, large deformation, and simulation of manufacturing processes, meshfree methods have gained much attention by researchers. A number of meshfree methods have been proposed till now for analyzing complex problems in various fields of engineering. Present work attempts to review recent developments and some earlier applications of well-known meshfree methods like EFG and MLPG to various types of structure mechanics and fracture mechanics applications like bending, buckling, free vibration analysis, sensitivity analysis and topology optimization, single and mixed mode crack problems, fatigue crack growth, and dynamic crack analysis and some typical applications like vibration of cracked structures, thermoelastic crack problems, and failure transition in impact problems. Due to complex nature of meshfree shape functions and evaluation of integrals in domain, meshless methods are computationally expensive as compared to conventional mesh based methods. Some improved versions of original meshfree methods and other techniques suggested by researchers to improve computational efficiency of meshfree methods are also reviewed here.

  12. Crypto-Giardia antigen rapid test versus conventional modified Ziehl-Neelsen acid fast staining method for diagnosis of cryptosporidiosis.

    PubMed

    Zaglool, Dina Abdulla Muhammad; Mohamed, Amr; Khodari, Yousif Abdul Wahid; Farooq, Mian Usman

    2013-03-01

    To evaluate the validity of Crypto-Giardia antigen rapid test (CA-RT) in comparison with the conventional modified Ziehl-Neelsen acid fast (MZN-AF) staining method for the diagnosis of cryptosporidiosis. Fifteen preserved stool samples from previously confirmed infections were used as positive controls and 40 stool samples from healthy people were used as negative control. A total of 85 stool samples were collected from suspected patients with cryptosporidiosis over 6 months during the period from January till June, 2011. The study was conducted in the department of parasitology, central laboratory, Alnoor Specialist Hospital, Makkah, Saudi Arabia. All samples were subjected to CA-RT and conventional MZN-AF staining method. Validation parameters including sensitivity (SN), specificity (SP), accuracy index (AI), positive predictive value (PPV), and negative predictive value (NPV) were evaluated for both tests. Out of 15 positive controls, CA-RT detected 13 (86.7%) while MZN-AF detected 11(73.3%) positive cases. However, CA-RT detected no positive case in 40 normal controls but MZN-AF detected 2(5%) as positive cases. Based on the results, the SN, SP, AI, PPV and NPV were high in CA-RT than MZN-AF staining method, ie., 86.7%vs. 73.3%, 100%vs. 95%, 96.4%vs. 89.1%, 100%vs. 84.6% and 95.2%vs. 90.5%, respectively. Out of a total of 85 suspected specimens, CA-RT detected 7(8.2%) but MZN-AF detected 6(7.1%) cases as positive. CA-RT immunoassay is more valid and reliable than MZN-AF staining method. Copyright © 2013 Hainan Medical College. Published by Elsevier B.V. All rights reserved.

  13. Developing a new case based computer-aided detection scheme and an adaptive cueing method to improve performance in detecting mammographic lesions

    PubMed Central

    Tan, Maxine; Aghaei, Faranak; Wang, Yunzhi; Zheng, Bin

    2017-01-01

    The purpose of this study is to evaluate a new method to improve performance of computer-aided detection (CAD) schemes of screening mammograms with two approaches. In the first approach, we developed a new case based CAD scheme using a set of optimally selected global mammographic density, texture, spiculation, and structural similarity features computed from all four full-field digital mammography (FFDM) images of the craniocaudal (CC) and mediolateral oblique (MLO) views by using a modified fast and accurate sequential floating forward selection feature selection algorithm. Selected features were then applied to a “scoring fusion” artificial neural network (ANN) classification scheme to produce a final case based risk score. In the second approach, we combined the case based risk score with the conventional lesion based scores of a conventional lesion based CAD scheme using a new adaptive cueing method that is integrated with the case based risk scores. We evaluated our methods using a ten-fold cross-validation scheme on 924 cases (476 cancer and 448 recalled or negative), whereby each case had all four images from the CC and MLO views. The area under the receiver operating characteristic curve was AUC = 0.793±0.015 and the odds ratio monotonically increased from 1 to 37.21 as CAD-generated case based detection scores increased. Using the new adaptive cueing method, the region based and case based sensitivities of the conventional CAD scheme at a false positive rate of 0.71 per image increased by 2.4% and 0.8%, respectively. The study demonstrated that supplementary information can be derived by computing global mammographic density image features to improve CAD-cueing performance on the suspicious mammographic lesions. PMID:27997380

  14. A novel evaluation strategy for fatigue reliability of flexible nanoscale films

    NASA Astrophysics Data System (ADS)

    Zheng, Si-Xue; Luo, Xue-Mei; Wang, Dong; Zhang, Guang-Ping

    2018-03-01

    In order to evaluate fatigue reliability of nanoscale metal films on flexible substrates, here we proposed an effective evaluation way to obtain critical fatigue cracking strain based on the direct observation of fatigue damage sites through conventional dynamic bending testing technique. By this method, fatigue properties and damage behaviors of 930 nm-thick Au films and 600 nm-thick Mo-W multilayers with individual layer thickness 100 nm on flexible polyimide substrates were investigated. Coffin-Manson relationship between the fatigue life and the applied strain range was obtained for the Au films and Mo-W multilayers. The characterization of fatigue damage behaviors verifies the feasibility of this method, which seems easier and more effective comparing with the other testing methods.

  15. In vitro evaluation of an alternative method to bond molar tubes

    PubMed Central

    PINZAN-VERCELINO, Célia Regina Maio; PINZAN, Arnaldo; GURGEL, Júlio de Araújo; BRAMANTE, Fausto Silva; PINZAN, Luciana Maio

    2011-01-01

    Despite the advances in bonding materials, many clinicians today still prefer to place bands on molar teeth. Molar bonding procedures need improvement to be widely accepted clinically. Objective The purpose of this study was to evaluate the shear bond strength when an additional adhesive layer was applied on the occlusal tooth/tube interface to provide reinforcement to molar tubes. Material and methods Sixty third molars were selected and allocated to the 3 groups: group 1 received a conventional direct bond followed by the application of an additional layer of adhesive on the occlusal tooth/tube interface, group 2 received a conventional direct bond, and group 3 received a conventional direct bond and an additional cure time of 10 s. The specimens were debonded in a universal testing machine. The results were analyzed statistically by ANOVA and Tukey’s test (α=0.05). Results Group 1 had a significantly higher (p<0.05) shear bond strength compared to groups 2 and 3. No difference was detected between groups 2 and 3 (p>0.05). Conclusions The present in vitro findings indicate that the application of an additional layer of adhesive on the tooth/tube interface increased the shear bond strength of the bonded molar tubes. PMID:21437468

  16. [Methicillin resistance detection in Staphylococcus aureus: comparison between conventional methods and MRSA-Screen latex agglutination technique].

    PubMed

    Soloaga, R; Corso, A; Gagetti, P; Faccone, D; Galas, M

    2004-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a significant pathogen that has emerged over the last four decades, causing both nosocomial and community-acquired infections. Rapid and accurate detection of methicillin resistance in S. aureus is important for the use of appropriate antimicrobial therapy and for the control of nosocomial spread of MRSA strains. We evaluated the efficiency of conventional methods for detection of methicillin resistance such as the disk diffusion, agar dilution, oxacillin agar screen test, and the latex agglutination test MRSA-Screen latex, in 100 isolates of S. aureus, 79 mecA positive and 21 mecA negative. The MRSA-Screen latex (Denka Seiken, Niigata, Japón), is a latex agglutination method that detects the presence of PLP-2a, product of mecA gene in S. aureus. The PCR of the mecA gene was used as the "gold standard" for the evaluation of the different methods tested. The percentages of sensitivity and specificity were as follows: disk difusión 97 and 100%, agar dilution 97 and 95%, oxacillin agar screen test 100 and 100%, and MRSA-Screen latex, 100 and 100 %. All methods presented high sensitivity and specificity, but MRSA-Screen latex had the advantage of giving a reliable result, equivalent to PCR, in only 15 minutes.

  17. Gate frequency sweep: An effective method to evaluate the dynamic performance of AlGaN/GaN power heterojunction field effect transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Santi, C. de; Meneghini, M., E-mail: matteo.meneghini@dei.unipd.it; Meneghesso, G.

    2014-08-18

    With this paper we propose a test method for evaluating the dynamic performance of GaN-based transistors, namely, gate-frequency sweep measurements: the effectiveness of the method is verified by characterizing the dynamic performance of Gate Injection Transistors. We demonstrate that this method can provide an effective description of the impact of traps on the transient performance of Heterojunction Field Effect Transistors, and information on the properties (activation energy and cross section) of the related defects. Moreover, we discuss the relation between the results obtained by gate-frequency sweep measurements and those collected by conventional drain current transients and double pulse characterization.

  18. Color-coded visualization of magnetic resonance imaging multiparametric maps

    NASA Astrophysics Data System (ADS)

    Kather, Jakob Nikolas; Weidner, Anja; Attenberger, Ulrike; Bukschat, Yannick; Weis, Cleo-Aron; Weis, Meike; Schad, Lothar R.; Zöllner, Frank Gerrit

    2017-01-01

    Multiparametric magnetic resonance imaging (mpMRI) data are emergingly used in the clinic e.g. for the diagnosis of prostate cancer. In contrast to conventional MR imaging data, multiparametric data typically include functional measurements such as diffusion and perfusion imaging sequences. Conventionally, these measurements are visualized with a one-dimensional color scale, allowing only for one-dimensional information to be encoded. Yet, human perception places visual information in a three-dimensional color space. In theory, each dimension of this space can be utilized to encode visual information. We addressed this issue and developed a new method for tri-variate color-coded visualization of mpMRI data sets. We showed the usefulness of our method in a preclinical and in a clinical setting: In imaging data of a rat model of acute kidney injury, the method yielded characteristic visual patterns. In a clinical data set of N = 13 prostate cancer mpMRI data, we assessed diagnostic performance in a blinded study with N = 5 observers. Compared to conventional radiological evaluation, color-coded visualization was comparable in terms of positive and negative predictive values. Thus, we showed that human observers can successfully make use of the novel method. This method can be broadly applied to visualize different types of multivariate MRI data.

  19. Chemical-free inactivated whole influenza virus vaccine prepared by ultrashort pulsed laser treatment

    NASA Astrophysics Data System (ADS)

    Tsen, Shaw-Wei David; Donthi, Nisha; La, Victor; Hsieh, Wen-Han; Li, Yen-Der; Knoff, Jayne; Chen, Alexander; Wu, Tzyy-Choou; Hung, Chien-Fu; Achilefu, Samuel; Tsen, Kong-Thon

    2015-05-01

    There is an urgent need for rapid methods to develop vaccines in response to emerging viral pathogens. Whole inactivated virus (WIV) vaccines represent an ideal strategy for this purpose; however, a universal method for producing safe and immunogenic inactivated vaccines is lacking. Conventional pathogen inactivation methods such as formalin, heat, ultraviolet light, and gamma rays cause structural alterations in vaccines that lead to reduced neutralizing antibody specificity, and in some cases, disastrous T helper type 2-mediated immune pathology. We have evaluated the potential of a visible ultrashort pulsed (USP) laser method to generate safe and immunogenic WIV vaccines without adjuvants. Specifically, we demonstrate that vaccination of mice with laser-inactivated H1N1 influenza virus at about a 10-fold lower dose than that required using conventional formalin-inactivated influenza vaccines results in protection against lethal H1N1 challenge in mice. The virus, inactivated by the USP laser irradiation, has been shown to retain its surface protein structure through hemagglutination assay. Unlike conventional inactivation methods, laser treatment did not generate carbonyl groups in protein, thereby reducing the risk of adverse vaccine-elicited T helper type 2 responses. Therefore, USP laser treatment is an attractive potential strategy to generate WIV vaccines with greater potency and safety than vaccines produced by current inactivation techniques.

  20. Impact of Cultivation Conditions, Ethylene Treatment, and Postharvest Storage on Selected Quality and Bioactivity Parameters of Kiwifruit "Hayward" Evaluated by Analytical and Chemometric Methods.

    PubMed

    Park, Yong Seo; Polovka, Martin; Ham, Kyung-Sik Ham; Park, Yang-Kyun; Vearasilp, Suchada; Namieśnik, Jacek; Toledo, Fernando; Arancibia-Avila, Patricia; Gorinstein, Shela

    2016-09-01

    Organic, semiorganic, and conventional "Hayward" kiwifruits, treated with ethylene for 24 h and stored during 10 days, were assessed by UV spectrometry, fluorometry, and chemometrical analysis for changes in selected characteristics of quality (firmness, dry matter and soluble solid contents, pH, and acidity) and bioactivity (concentration of polyphenols via Folin-Ciocalteu and p-hydroxybenzoic acid assays). All of the monitored qualitative parameters and characteristics related to bioactivity were affected either by cultivation practices or by ethylene treatment and storage. Results obtained, supported by statistical evaluation (Friedman two-way ANOVA) and chemometric analysis, clearly proved that the most significant impact on the majority of the evaluated parameters of quality and bioactivity of "Hayward" kiwifruit had the ethylene treatment followed by the cultivation practices and the postharvest storage. Total concentration of polyphenols expressed via p-hydroxybenzoic acid assay exhibited the most significant sensitivity to all three evaluated parameters, reaching a 16.5% increase for fresh organic compared to a conventional control sample. As a result of postharvest storage coupled with ethylene treatment, the difference increased to 26.3%. Three-dimensional fluorescence showed differences in the position of the main peaks and their fluorescence intensity for conventional, semiorganic, and organic kiwifruits in comparison with ethylene nontreated samples.

  1. Review and evaluation of models that produce trip tables from ground counts : interim report.

    DOT National Transportation Integrated Search

    1996-01-01

    This research effort was motivated by the desires of planning agencies to seek alternative methods of deriving current or base year Origin-Destination (O-D) trip tables without adopting conventional O-D surveys that are expensive, time consuming and ...

  2. Persistent Ratee Contaminants in Performance Appraisal.

    ERIC Educational Resources Information Center

    Van Fleet, David D.; Chamberlain, Howard

    The hypothesis that conventional approaches to evaluating contaminants in performance appraisal overlook important individual ratee effects was examined. A rating form was developed that consisted of the following dimensions and behaviors: warmth; guided discourse or indirect teaching methods; control of subject matter; enthusiasm and reinforcing;…

  3. A multivariate variational objective analysis-assimilation method. Part 2: Case study results with and without satellite data

    NASA Technical Reports Server (NTRS)

    Achtemeier, Gary L.; Kidder, Stanley Q.; Scott, Robert W.

    1988-01-01

    The variational multivariate assimilation method described in a companion paper by Achtemeier and Ochs is applied to conventional and conventional plus satellite data. Ground-based and space-based meteorological data are weighted according to the respective measurement errors and blended into a data set that is a solution of numerical forms of the two nonlinear horizontal momentum equations, the hydrostatic equation, and an integrated continuity equation for a dry atmosphere. The analyses serve first, to evaluate the accuracy of the model, and second to contrast the analyses with and without satellite data. Evaluation criteria measure the extent to which: (1) the assimilated fields satisfy the dynamical constraints, (2) the assimilated fields depart from the observations, and (3) the assimilated fields are judged to be realistic through pattern analysis. The last criterion requires that the signs, magnitudes, and patterns of the hypersensitive vertical velocity and local tendencies of the horizontal velocity components be physically consistent with respect to the larger scale weather systems.

  4. Investigation into photostability of soybean oils by thermal lens spectroscopy

    NASA Astrophysics Data System (ADS)

    Savi, E. L.; Malacarne, L. C.; Baesso, M. L.; Pintro, P. T. M.; Croge, C.; Shen, J.; Astrath, N. G. C.

    2015-06-01

    Assessment of photochemical stability is essential for evaluating quality and the shelf life of vegetable oils, which are very important aspects of marketing and human health. Most of conventional methods used to investigate oxidative stability requires long time experimental procedures with high consumption of chemical inputs for the preparation or extraction of sample compounds. In this work we propose a time-resolved thermal lens method to analyze photostability of edible oils by quantitative measurement of photoreaction cross-section. An all-numerical routine is employed to solve a complex theoretical problem involving photochemical reaction, thermal lens effect, and mass diffusion during local laser excitation. The photostability of pure oil and oils with natural and synthetic antioxidants is investigated. The thermal lens results are compared with those obtained by conventional methods, and a complete set of physical properties of the samples is presented.

  5. Remote sensing change detection methods to track deforestation and growth in threatened rainforests in Madre de Dios, Peru

    USGS Publications Warehouse

    Shermeyer, Jacob S.; Haack, Barry N.

    2015-01-01

    Two forestry-change detection methods are described, compared, and contrasted for estimating deforestation and growth in threatened forests in southern Peru from 2000 to 2010. The methods used in this study rely on freely available data, including atmospherically corrected Landsat 5 Thematic Mapper and Moderate Resolution Imaging Spectroradiometer (MODIS) vegetation continuous fields (VCF). The two methods include a conventional supervised signature extraction method and a unique self-calibrating method called MODIS VCF guided forest/nonforest (FNF) masking. The process chain for each of these methods includes a threshold classification of MODIS VCF, training data or signature extraction, signature evaluation, k-nearest neighbor classification, analyst-guided reclassification, and postclassification image differencing to generate forest change maps. Comparisons of all methods were based on an accuracy assessment using 500 validation pixels. Results of this accuracy assessment indicate that FNF masking had a 5% higher overall accuracy and was superior to conventional supervised classification when estimating forest change. Both methods succeeded in classifying persistently forested and nonforested areas, and both had limitations when classifying forest change.

  6. Evaluation of a global algorithm for wavefront reconstruction for Shack-Hartmann wave-front sensors and thick fundus reflectors.

    PubMed

    Liu, Tao; Thibos, Larry; Marin, Gildas; Hernandez, Martha

    2014-01-01

    Conventional aberration analysis by a Shack-Hartmann aberrometer is based on the implicit assumption that an injected probe beam reflects from a single fundus layer. In fact, the biological fundus is a thick reflector and therefore conventional analysis may produce errors of unknown magnitude. We developed a novel computational method to investigate this potential failure of conventional analysis. The Shack-Hartmann wavefront sensor was simulated by computer software and used to recover by two methods the known wavefront aberrations expected from a population of normally-aberrated human eyes and bi-layer fundus reflection. The conventional method determines the centroid of each spot in the SH data image, from which wavefront slopes are computed for least-squares fitting with derivatives of Zernike polynomials. The novel 'global' method iteratively adjusted the aberration coefficients derived from conventional centroid analysis until the SH image, when treated as a unitary picture, optimally matched the original data image. Both methods recovered higher order aberrations accurately and precisely, but only the global algorithm correctly recovered the defocus coefficients associated with each layer of fundus reflection. The global algorithm accurately recovered Zernike coefficients for mean defocus and bi-layer separation with maximum error <0.1%. The global algorithm was robust for bi-layer separation up to 2 dioptres for a typical SH wavefront sensor design. For 100 randomly generated test wavefronts with 0.7 D axial separation, the retrieved mean axial separation was 0.70 D with standard deviations (S.D.) of 0.002 D. Sufficient information is contained in SH data images to measure the dioptric thickness of dual-layer fundus reflection. The global algorithm is superior since it successfully recovered the focus value associated with both fundus layers even when their separation was too small to produce clearly separated spots, while the conventional analysis misrepresents the defocus component of the wavefront aberration as the mean defocus for the two reflectors. Our novel global algorithm is a promising method for SH data image analysis in clinical and visual optics research for human and animal eyes. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  7. Comparison of the Debonding Characteristics of Conventional and New Debonding Instrument used for Ceramic, Composite and Metallic Brackets – An Invitro Study

    PubMed Central

    Gill, Vikas; Reddy, Y. N. N.; Sanadhya, Sudhanshu; Aapaliya, Pankaj; Sharma, Nidhi

    2014-01-01

    Background: Debonding procedure is time consuming and damaging to the enamel if performed with improper technique. Various debonding methods include: the conventional methods that use pliers or wrenches, an ultrasonic method, electrothermal devices, air pressure impulse devices, diamond burs to grind the brackets off the tooth surface and lasers. Among all these methods, using debonding pliers is most convenient and effective method but has been reported to cause damage to the teeth. Recently, a New Debonding Instrument designed specifically for ceramic and composite brackets has been introduced. As this is a new instrument, little information is available on efficacy of this instrument. The purpose of this study was to evaluate the debonding characteristics of both “the conventional debonding Pliers” and “the New debonding instrument” when removing ceramic, composite and metallic brackets. Materials and Methods: One Hundred Thirty eight extracted maxillary premolar teeth were collected and divided into two Groups: Group A and Group B (n = 69) respectively. They were further divided into 3 subGroups (n = 23) each according to the types of brackets to be bonded. In subGroups A1 and B1{stainless steel};A2 and B2{ceramic};A3 and B3{composite}adhesive precoated maxillary premolar brackets were used. Among them {ceramic and composite} adhesive pre-coated maxillary premolar brackets were bonded. All the teeth were etched using 37% phosphoric acid for 15 seconds and the brackets were bonded using Transbond XT primer. Brackets were debonded using Conventional Debonding Plier and New Debonding Instrument (Group B). After debonding, the enamel surface of each tooth was examined under stereo microscope (10X magnifications). Amodifiedadhesive remnant index (ARI) was used to quantify the amount of remaining adhesive on each tooth. Results: The observations demonstrate that the results of New Debonding Instrument for debonding of metal, ceramic and composite brackets were statistically significantly different (p = 0.04) and superior from the results of conventional debonding Pliers. Conclusion: The debonding efficiency of New Debonding Instrument is better than the debonding efficiency of Conventional Debonding Pliers for use of metal, ceramic and composite brackets respectively. PMID:25177639

  8. Inspection of timber bridges using stress wave timing nondestructive evaluation tools : a guide for use and interpretation

    Treesearch

    Robert J. Ross; Roy F. Pellerin; Norbert Volny; William W. Salsig; Robert H. Falk

    1999-01-01

    This guide was prepared to assist inspectors in the use of stress wave timing instruments and the various methods of locating and defining areas of decay in timber bridge members. The first two sections provide (a) background information regarding conventional methods to locate and measure decay in timber bridges and (b) the principles of stress wave nondestructive...

  9. Stress wave timing nondestructive evaluation tools for inspecting historic structures : a guide for use and interpretation.

    Treesearch

    Robert Ross; Roy F. Pellerin; Norbert Volny; William W. Salsig; Robert H. Falk

    2000-01-01

    This guide was prepared to assist inspectors in the use of stress wave timing instruments and various methods of locating and defining areas of decay in timber members in historic structures. The first two sections provide (a) background information regarding conventional methods to locate and measure decay in historic structures and (b) the principles of stress wave...

  10. Hot Corrosion Resistance and Mechanical Behavior of Atmospheric Plasma Sprayed Conventional and Nanostructured Zirconia Coatings

    NASA Astrophysics Data System (ADS)

    Saremi, Mohsen; Keyvani, Ahmad; Heydarzadeh Sohi, Mahmoud

    Conventional and nanostructured zirconia coatings were deposited on In-738 Ni super alloy by atmospheric plasma spray technique. The hot corrosion resistance of the coatings was measured at 1050°C using an atmospheric electrical furnace and a fused mixture of vanadium pent oxide and sodium sulfate respectively. According to the experimental results nanostructured coatings showed a better hot corrosion resistance than conventional ones. The improved hot corrosion resistance could be explained by the change of structure to a dense and more packed structure in the nanocoating. The evaluation of mechanical properties by nano indentation method showed the hardness (H) and elastic modulus (E) of the YSZ coating increased substantially after hot corrosion.

  11. A comparison study on microwave-assisted extraction of Artemisia sphaerocephala polysaccharides with conventional method: Molecule structure and antioxidant activities evaluation.

    PubMed

    Wang, Junlong; Zhang, Ji; Wang, Xiaofang; Zhao, Baotang; Wu, Yiqian; Yao, Jian

    2009-12-01

    The conventional extraction methods for polysaccharides were time-consuming, laborious and energy-consuming. Microwave-assisted extraction (MAE) technique was employed for the extraction of Artemisia sphaerocephala polysaccharides (ASP), which is a traditional Chinese food. The extracting parameters were optimized by Box-Behnken design. In microwave heating process, a decrease in molecular weight (M(w)) was detected in SEC-LLS measurement. A d(f) value of 2.85 indicated ASP using MAE exhibited as a sphere conformation of branched clusters in aqueous solution. Furthermore, it showed stronger antioxidant activities compared with hot water extraction. The data obtained showed that the molecular weights played a more important role in antioxidant activities.

  12. Development and evaluation of the impulse transfer function technique

    NASA Technical Reports Server (NTRS)

    Mantus, M.

    1972-01-01

    The development of the test/analysis technique known as the impulse transfer function (ITF) method is discussed. This technique, when implemented with proper data processing systems, should become a valuable supplement to conventional dynamic testing and analysis procedures that will be used in the space shuttle development program. The method can relieve many of the problems associated with extensive and costly testing of the shuttle for transient loading conditions. In addition, the time history information derived from impulse testing has the potential for being used to determine modal data for the structure under investigation. The technique could be very useful in determining the time-varying modal characteristics of structures subjected to thermal transients, where conventional mode surveys are difficult to perform.

  13. Cross-correlation analysis of pulse wave propagation in arteries: in vitro validation and in vivo feasibility

    NASA Astrophysics Data System (ADS)

    Nauleau, Pierre; Apostolakis, Iason; McGarry, Matthew; Konofagou, Elisa

    2018-06-01

    The stiffness of the arteries is known to be an indicator of the progression of various cardiovascular diseases. Clinically, the pulse wave velocity (PWV) is used as a surrogate for arterial stiffness. Pulse wave imaging (PWI) is a non-invasive, ultrasound-based imaging technique capable of mapping the motion of the vessel walls, allowing the local assessment of arterial properties. Conventionally, a distinctive feature of the displacement wave (e.g. the 50% upstroke) is tracked across the map to estimate the PWV. However, the presence of reflections, such as those generated at the carotid bifurcation, can bias the PWV estimation. In this paper, we propose a two-step cross-correlation based method to characterize arteries using the information available in the PWI spatio-temporal map. First, the area under the cross-correlation curve is proposed as an index for locating the regions of different properties. Second, a local peak of the cross-correlation function is tracked to obtain a less biased estimate of the PWV. Three series of experiments were conducted in phantoms to evaluate the capabilities of the proposed method compared with the conventional method. In the ideal case of a homogeneous phantom, the two methods performed similarly and correctly estimated the PWV. In the presence of reflections, the proposed method provided a more accurate estimate than conventional processing: e.g. for the soft phantom, biases of  ‑0.27 and ‑0.71 m · s–1 were observed. In a third series of experiments, the correlation-based method was able to locate two regions of different properties with an error smaller than 1 mm. It also provided more accurate PWV estimates than conventional processing (biases:  ‑0.12 versus ‑0.26 m · s–1). Finally, the in vivo feasibility of the proposed method was demonstrated in eleven healthy subjects. The results indicate that the correlation-based method might be less precise in vivo but more accurate than the conventional method.

  14. Relationship between Testicular Volume and Conventional or Nonconventional Sperm Parameters

    PubMed Central

    Condorelli, Rosita; Calogero, Aldo E.; La Vignera, Sandro

    2013-01-01

    Background. Reduced testicular volume (TV) (<12 cm3) is associated with lower testicular function. Several studies explored the conventional sperm parameters (concentration, motility, and morphology) and the endocrine function (gonadotropins and testosterone serum concentrations) in the patients with reduction of TV. No other parameters have been examined. Aim. This study aims at evaluating some biofunctional sperm parameters by flow cytometry in the semen of men with reduced TV compared with that of subjects with normal TV. Methods. 78 patients without primary scrotal disease were submitted to ultrasound evaluation of the testis. They were divided into two groups according to testicular volume: A Group, including 40 patients with normal testicular volume (TV > 15 cm3) and B Group, including 38 patients with reduced testicular volume (TV ≤ 12 cm3). All patients underwent serum hormone concentration, conventional and biofunctional (flow cytometry) sperm parameters evaluation. Results. With regard to biofunctional sperm parameters, all values (mitochondrial membrane potential, phosphatidylserine externalization, chromatin compactness, and DNA fragmentation) were strongly negatively correlated with testicular volume (P < 0.0001). Conclusions. This study for the first time in the literature states that the biofunctional sperm parameters worsen and with near linear correlation, with decreasing testicular volume. PMID:24089610

  15. Effect of organic and conventional rearing system on the mineral content of pork.

    PubMed

    Zhao, Yan; Wang, Donghua; Yang, Shuming

    2016-08-01

    Dietary composition and rearing regime largely determine the trace elemental composition of pigs, and consequently their concentration in animal products. The present study evaluates thirteen macro- and trace element concentrations in pork from organic and conventional farms. Conventional pigs were given a commercial feed with added minerals; organic pigs were given a feed based on organic feedstuffs. The content of macro-elements (Na, K, Mg and Ca) and some trace elements (Ni, Fe, Zn and Sr) in organic and conventional meat samples showed no significant differences (P>0.05). Several trace element concentrations in organic pork were significantly higher (P<0.05) compared to conventional pork: Cr (808 and 500μg/kg in organic and conventional pork, respectively), Mn (695 and 473μg/kg) and Cu (1.80 and 1.49mg/kg). The results showed considerable differences in mineral content between samples from pigs reared in organic and conventional systems. Our results also indicate that authentication of organic pork can be realized by applying multivariate chemometric methods such as discriminant analysis to this multi-element data. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Comparison between a Direct-Flow SPR Immunosensor for Ampicillin and a Competitive Conventional Amperometric Device: Analytical Features and Possible Applications to Real Samples

    PubMed Central

    Tomassetti, Mauro; Merola, Giovanni; Martini, Elisabetta; Campanella, Luigi; Sanzò, Gabriella; Favero, Gabriele; Mazzei, Franco

    2017-01-01

    In this research, we developed a direct-flow surface plasmon resonance (SPR) immunosensor for ampicillin to perform direct, simple, and fast measurements of this important antibiotic. In order to better evaluate the performance, it was compared with a conventional amperometric immunosensor, working with a competitive format with the aim of finding out experimental real advantages and disadvantages of two respective methods. Results showed that certain analytical features of the new SPR immunodevice, such as the lower limit of detection (LOD) value and the width of the linear range, are poorer than those of a conventional amperometric immunosensor, which adversely affects the application to samples such as natural waters. On the other hand, the SPR immunosensor was more selective to ampicillin, and measurements were more easily and quickly attained compared to those performed with the conventional competitive immunosensor. PMID:28394296

  17. [Cytocompatibility of nanophase hydroxyapatite ceramics].

    PubMed

    Wen, Bo; Chen, Zhi-qing; Jiang, Yin-shan; Yang, Zheng-wen; Xu, Yong-zhong

    2004-12-01

    To evaluate the cytocompatibility of nanophase hydroxyapatite ceramics in vitro. Hydroxyapatite (HA) was prepared via wet method. The grain size of the hydroxyapatite in the study was determined by scanning electron microscope and atomic force microscope with image analysis software. Primary osteoblast culture was established from rat calvaria. Cell adherence and proliferation on nanophase hydroxyapatite ceramics and conventional hydroxyapatite ceramics were examined at 1, 3, 5, 7 days. Morphology of the cells was observed by microscope. The average grain size of the nanophase and conventional HA was 55 nm and 780 nm, respectively. Throughout 7 days period, osteoblast proliferation on the HA was similar to that on tissue culture borosilicate glass controls, osteoblasts could attach, spread and proliferate on HA. However, compared to conventional ceramics, osteoblast proliferation on nanophase HA was significantly better after 1, 3, 5 and 7 days. Cytocompatibility of nanophase HA was significantly better than conventional ceramics.

  18. Using a fuzzy comprehensive evaluation method to determine product usability: A test case

    PubMed Central

    Zhou, Ronggang; Chan, Alan H. S.

    2016-01-01

    BACKGROUND: In order to take into account the inherent uncertainties during product usability evaluation, Zhou and Chan [1] proposed a comprehensive method of usability evaluation for products by combining the analytic hierarchy process (AHP) and fuzzy evaluation methods for synthesizing performance data and subjective response data. This method was designed to provide an integrated framework combining the inevitable vague judgments from the multiple stages of the product evaluation process. OBJECTIVE AND METHODS: In order to illustrate the effectiveness of the model, this study used a summative usability test case to assess the application and strength of the general fuzzy usability framework. To test the proposed fuzzy usability evaluation framework [1], a standard summative usability test was conducted to benchmark the overall usability of a specific network management software. Based on the test data, the fuzzy method was applied to incorporate both the usability scores and uncertainties involved in the multiple components of the evaluation. Then, with Monte Carlo simulation procedures, confidence intervals were used to compare the reliabilities among the fuzzy approach and two typical conventional methods combining metrics based on percentages. RESULTS AND CONCLUSIONS: This case study showed that the fuzzy evaluation technique can be applied successfully for combining summative usability testing data to achieve an overall usability quality for the network software evaluated. Greater differences of confidence interval widths between the method of averaging equally percentage and weighted evaluation method, including the method of weighted percentage averages, verified the strength of the fuzzy method. PMID:28035942

  19. ERTS: A multispectral image analysis contribution for the geomorphological evaluation of southern Maracaibo Lake Basin. [geological survey and drainage patterns

    NASA Technical Reports Server (NTRS)

    Salas, F.; Cabello, O.; Alarcon, F.; Ferrer, C.

    1974-01-01

    Multispectral analysis of ERTS-A images at scales of 1:1,000,000 and 1:500,000 has been conducted with conventional photointerpretation methods. Specific methods have been developed for the geomorphological analysis of southern Maracaibo Lake Basin which comprises part of the Venezuelan Andean Range, Perija Range, the Tachira gap and the Southern part of the Maracaibo Lake depression. A steplike analysis was conducted to separate macroforms, landscapes and relief units as well as drainage patterns and tectonic features, which permitted the delineation of tectonic provinces, stratigraphic units, geomorphologic units and geomorphologic positions. The geomorphologic synthesis obtained compares favorably with conventional analysis made on this area for accuracy of 1:100,000 scale, and in some features with details obtained through conventional analysis for accuracy of 1:15,000 and field work. Geomorphological units in the mountains were identified according to changes in tone, texture, forms orientation of interfluves and tectonic characteristics which control interfluvial disimetrics.

  20. Conventional and Accelerated-Solvent Extractions of Green Tea (Camellia sinensis) for Metabolomics-based Chemometrics

    PubMed Central

    Kellogg, Joshua J.; Wallace, Emily D.; Graf, Tyler N.; Oberlies, Nicholas H.; Cech, Nadja B.

    2018-01-01

    Metabolomics has emerged as an important analytical technique for multiple applications. The value of information obtained from metabolomics analysis depends on the degree to which the entire metabolome is present and the reliability of sample treatment to ensure reproducibility across the study. The purpose of this study was to compare methods of preparing complex botanical extract samples prior to metabolomics profiling. Two extraction methodologies, accelerated solvent extraction and a conventional solvent maceration, were compared using commercial green tea [Camellia sinensis (L.) Kuntze (Theaceae)] products as a test case. The accelerated solvent protocol was first evaluated to ascertain critical factors influencing extraction using a D-optimal experimental design study. The accelerated solvent and conventional extraction methods yielded similar metabolite profiles for the green tea samples studied. The accelerated solvent extraction yielded higher total amounts of extracted catechins, was more reproducible, and required less active bench time to prepare the samples. This study demonstrates the effectiveness of accelerated solvent as an efficient methodology for metabolomics studies. PMID:28787673

  1. Holographic Refraction and the Measurement of Spherical Ametropia.

    PubMed

    Nguyen, Nicholas Hoai Nam

    2016-10-01

    To evaluate the performance of a holographic logMAR chart for the subjective spherical refraction of the human eye. Bland-Altman analysis was used to assess the level of agreement between subjective spherical refraction using the holographic logMAR chart and conventional autorefraction and subjective spherical refraction. The 95% limits of agreement (LoA) were calculated between holographic refraction and the two standard methods (subjective and autorefraction). Holographic refraction has a lower mean spherical refraction when compared to conventional refraction (LoA 0.11 ± 0.65 D) and when compared to autorefraction (LoA 0.36 ± 0.77 D). After correcting for systemic bias, this is comparable between autorefraction and conventional subjective refraction (LoA 0.45 ± 0.79 D). After correcting for differences in vergence distance and chromatic aberration between holographic and conventional refraction, approximately 65% (group 1) of measurements between holography and conventional subjective refraction were similar (MD = 0.13 D, SD = 0.00 D). The remaining 35% (group 2) had a mean difference of 0.45 D (SD = 0.12 D) between the two subjective methods. Descriptive statistics showed group 2's mean age (21 years, SD = 13 years) was considerably lower than group 1's mean age (41 years, SD = 17), suggesting accommodation may have a role in the greater mean difference of group 2. Overall, holographic refraction has good agreement with conventional refraction and is a viable alternative for spherical subjective refraction. A larger bias between holographic and conventional refraction was found in younger subjects than older subjects, suggesting an association between accommodation and myopic over-correction during holographic refraction.

  2. Extraction of organic contaminants from marine sediments and tissues using microwave energy.

    PubMed

    Jayaraman, S; Pruell, R J; McKinney, R

    2001-07-01

    In this study, we compared microwave solvent extraction (MSE) to conventional methods for extracting organic contaminants from marine sediments and tissues with high and varying moisture content. The organic contaminants measured were polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, and polycyclic aromatic hydrocarbons (PAHs). Initial experiments were conducted on dry standard reference materials (SRMs) and field collected marine sediments. Moisture content in samples greatly influenced the recovery of the analytes of interest. When wet sediments were included in a sample batch, low recoveries were often encountered in other samples in the batch, including the dry SRM. Experiments were conducted to test the effect of standardizing the moisture content in all samples in a batch prior to extraction. SRM1941a (marine sediment). SRM1974a (mussel tissue), as well as QA96SED6 (marine sediment), and QA96TIS7 (marine tissue), both from 1996 NIST Intercalibration Exercise were extracted using microwave and conventional methods. Moisture levels were adjusted in SRMs to match those of marine sediment and tissue samples before microwave extraction. The results demonstrated that it is crucial to standardize the moisture content in all samples, including dry reference material to ensure good recovery of organic contaminants. MSE yielded equivalent or superior recoveries compared to conventional methods for the majority of the compounds evaluated. The advantages of MSE over conventional methods are reduced solvent usage, higher sample throughput and the elimination of halogenated solvent usage.

  3. Evaluating the dimensionality of first grade written composition

    PubMed Central

    Kim, Young-Suk; Al Otaiba, Stephanie; Folsom, Jessica S.; Greulich, Luana; Puranik, Cynthia

    2013-01-01

    Purpose We examined dimensions of written composition using multiple evaluative approaches such as an adapted 6+1 trait scoring, syntactic complexity measures, and productivity measures. We further examined unique relations of oral language and literacy skills to the identified dimensions of written composition. Method A large sample of first grade students (N = 527) was assessed on their language, reading, spelling, letter writing automaticity, and writing in the spring. Data were analyzed using a latent variable approach including confirmatory factor analysis and structural equation modeling. Results The seven traits in the 6+1 trait system were best described as two constructs: substantive quality, and spelling and writing conventions. When the other evaluation procedures such as productivity and syntactic complexity indicators were included, four dimensions emerged: substantive quality, productivity, syntactic complexity, and spelling and writing conventions. Language and literacy predictors were differentially related to each dimension in written composition. Conclusions These four dimensions may be a useful guideline for evaluating developing beginning writer’s compositions. PMID:24687472

  4. Bootstrap-based methods for estimating standard errors in Cox's regression analyses of clustered event times.

    PubMed

    Xiao, Yongling; Abrahamowicz, Michal

    2010-03-30

    We propose two bootstrap-based methods to correct the standard errors (SEs) from Cox's model for within-cluster correlation of right-censored event times. The cluster-bootstrap method resamples, with replacement, only the clusters, whereas the two-step bootstrap method resamples (i) the clusters, and (ii) individuals within each selected cluster, with replacement. In simulations, we evaluate both methods and compare them with the existing robust variance estimator and the shared gamma frailty model, which are available in statistical software packages. We simulate clustered event time data, with latent cluster-level random effects, which are ignored in the conventional Cox's model. For cluster-level covariates, both proposed bootstrap methods yield accurate SEs, and type I error rates, and acceptable coverage rates, regardless of the true random effects distribution, and avoid serious variance under-estimation by conventional Cox-based standard errors. However, the two-step bootstrap method over-estimates the variance for individual-level covariates. We also apply the proposed bootstrap methods to obtain confidence bands around flexible estimates of time-dependent effects in a real-life analysis of cluster event times.

  5. Development, verification, and application of a simplified method to estimate total-streambed scour at bridge sites in Illinois

    USGS Publications Warehouse

    Holmes, Robert R.; Dunn, Chad J.

    1996-01-01

    A simplified method to estimate total-streambed scour was developed for application to bridges in the State of Illinois. Scour envelope curves, developed as empirical relations between calculated total scour and bridge-site chracteristics for 213 State highway bridges in Illinois, are used in the method to estimate the 500-year flood scour. These 213 bridges, geographically distributed throughout Illinois, had been previously evaluated for streambed scour with the application of conventional hydraulic and scour-analysis methods recommended by the Federal Highway Administration. The bridge characteristics necessary for application of the simplified bridge scour-analysis method can be obtained from an office review of bridge plans, examination of topographic maps, and reconnaissance-level site inspection. The estimates computed with the simplified method generally resulted in a larger value of 500-year flood total-streambed scour than with the more detailed conventional method. The simplified method was successfully verified with a separate data set of 106 State highway bridges, which are geographically distributed throughout Illinois, and 15 county highway bridges.

  6. Multi-Institutional Evaluation of Digital Tomosynthesis, Dual-Energy Radiography, and Conventional Chest Radiography for the Detection and Management of Pulmonary Nodules.

    PubMed

    Dobbins, James T; McAdams, H Page; Sabol, John M; Chakraborty, Dev P; Kazerooni, Ella A; Reddy, Gautham P; Vikgren, Jenny; Båth, Magnus

    2017-01-01

    Purpose To conduct a multi-institutional, multireader study to compare the performance of digital tomosynthesis, dual-energy (DE) imaging, and conventional chest radiography for pulmonary nodule detection and management. Materials and Methods In this binational, institutional review board-approved, HIPAA-compliant prospective study, 158 subjects (43 subjects with normal findings) were enrolled at four institutions. Informed consent was obtained prior to enrollment. Subjects underwent chest computed tomography (CT) and imaging with conventional chest radiography (posteroanterior and lateral), DE imaging, and tomosynthesis with a flat-panel imaging device. Three experienced thoracic radiologists identified true locations of nodules (n = 516, 3-20-mm diameters) with CT and recommended case management by using Fleischner Society guidelines. Five other radiologists marked nodules and indicated case management by using images from conventional chest radiography, conventional chest radiography plus DE imaging, tomosynthesis, and tomosynthesis plus DE imaging. Sensitivity, specificity, and overall accuracy were measured by using the free-response receiver operating characteristic method and the receiver operating characteristic method for nodule detection and case management, respectively. Results were further analyzed according to nodule diameter categories (3-4 mm, >4 mm to 6 mm, >6 mm to 8 mm, and >8 mm to 20 mm). Results Maximum lesion localization fraction was higher for tomosynthesis than for conventional chest radiography in all nodule size categories (3.55-fold for all nodules, P < .001; 95% confidence interval [CI]: 2.96, 4.15). Case-level sensitivity was higher with tomosynthesis than with conventional chest radiography for all nodules (1.49-fold, P < .001; 95% CI: 1.25, 1.73). Case management decisions showed better overall accuracy with tomosynthesis than with conventional chest radiography, as given by the area under the receiver operating characteristic curve (1.23-fold, P < .001; 95% CI: 1.15, 1.32). There were no differences in any specificity measures. DE imaging did not significantly affect nodule detection when paired with either conventional chest radiography or tomosynthesis. Conclusion Tomosynthesis outperformed conventional chest radiography for lung nodule detection and determination of case management; DE imaging did not show significant differences over conventional chest radiography or tomosynthesis alone. These findings indicate performance likely achievable with a range of reader expertise. © RSNA, 2016 Online supplemental material is available for this article.

  7. Multi-Institutional Evaluation of Digital Tomosynthesis, Dual-Energy Radiography, and Conventional Chest Radiography for the Detection and Management of Pulmonary Nodules

    PubMed Central

    McAdams, H. Page; Sabol, John M.; Chakraborty, Dev P.; Kazerooni, Ella A.; Reddy, Gautham P.; Vikgren, Jenny; Båth, Magnus

    2017-01-01

    Purpose To conduct a multi-institutional, multireader study to compare the performance of digital tomosynthesis, dual-energy (DE) imaging, and conventional chest radiography for pulmonary nodule detection and management. Materials and Methods In this binational, institutional review board–approved, HIPAA-compliant prospective study, 158 subjects (43 subjects with normal findings) were enrolled at four institutions. Informed consent was obtained prior to enrollment. Subjects underwent chest computed tomography (CT) and imaging with conventional chest radiography (posteroanterior and lateral), DE imaging, and tomosynthesis with a flat-panel imaging device. Three experienced thoracic radiologists identified true locations of nodules (n = 516, 3–20-mm diameters) with CT and recommended case management by using Fleischner Society guidelines. Five other radiologists marked nodules and indicated case management by using images from conventional chest radiography, conventional chest radiography plus DE imaging, tomosynthesis, and tomosynthesis plus DE imaging. Sensitivity, specificity, and overall accuracy were measured by using the free-response receiver operating characteristic method and the receiver operating characteristic method for nodule detection and case management, respectively. Results were further analyzed according to nodule diameter categories (3–4 mm, >4 mm to 6 mm, >6 mm to 8 mm, and >8 mm to 20 mm). Results Maximum lesion localization fraction was higher for tomosynthesis than for conventional chest radiography in all nodule size categories (3.55-fold for all nodules, P < .001; 95% confidence interval [CI]: 2.96, 4.15). Case-level sensitivity was higher with tomosynthesis than with conventional chest radiography for all nodules (1.49-fold, P < .001; 95% CI: 1.25, 1.73). Case management decisions showed better overall accuracy with tomosynthesis than with conventional chest radiography, as given by the area under the receiver operating characteristic curve (1.23-fold, P < .001; 95% CI: 1.15, 1.32). There were no differences in any specificity measures. DE imaging did not significantly affect nodule detection when paired with either conventional chest radiography or tomosynthesis. Conclusion Tomosynthesis outperformed conventional chest radiography for lung nodule detection and determination of case management; DE imaging did not show significant differences over conventional chest radiography or tomosynthesis alone. These findings indicate performance likely achievable with a range of reader expertise. © RSNA, 2016 Online supplemental material is available for this article. PMID:27439324

  8. A Variational Assimilation Method for Satellite and Conventional Data: a Revised Basic Model 2B

    NASA Technical Reports Server (NTRS)

    Achtemeier, Gary L.; Scott, Robert W.; Chen, J.

    1991-01-01

    A variational objective analysis technique that modifies observations of temperature, height, and wind on the cyclone scale to satisfy the five 'primitive' model forecast equations is presented. This analysis method overcomes all of the problems that hindered previous versions, such as over-determination, time consistency, solution method, and constraint decoupling. A preliminary evaluation of the method shows that it converges rapidly, the divergent part of the wind is strongly coupled in the solution, fields of height and temperature are well-preserved, and derivative quantities such as vorticity and divergence are improved. Problem areas are systematic increases in the horizontal velocity components, and large magnitudes of the local tendencies of the horizontal velocity components. The preliminary evaluation makes note of these problems but detailed evaluations required to determine the origin of these problems await future research.

  9. Explicit optimization of plan quality measures in intensity-modulated radiation therapy treatment planning.

    PubMed

    Engberg, Lovisa; Forsgren, Anders; Eriksson, Kjell; Hårdemark, Björn

    2017-06-01

    To formulate convex planning objectives of treatment plan multicriteria optimization with explicit relationships to the dose-volume histogram (DVH) statistics used in plan quality evaluation. Conventional planning objectives are designed to minimize the violation of DVH statistics thresholds using penalty functions. Although successful in guiding the DVH curve towards these thresholds, conventional planning objectives offer limited control of the individual points on the DVH curve (doses-at-volume) used to evaluate plan quality. In this study, we abandon the usual penalty-function framework and propose planning objectives that more closely relate to DVH statistics. The proposed planning objectives are based on mean-tail-dose, resulting in convex optimization. We also demonstrate how to adapt a standard optimization method to the proposed formulation in order to obtain a substantial reduction in computational cost. We investigated the potential of the proposed planning objectives as tools for optimizing DVH statistics through juxtaposition with the conventional planning objectives on two patient cases. Sets of treatment plans with differently balanced planning objectives were generated using either the proposed or the conventional approach. Dominance in the sense of better distributed doses-at-volume was observed in plans optimized within the proposed framework. The initial computational study indicates that the DVH statistics are better optimized and more efficiently balanced using the proposed planning objectives than using the conventional approach. © 2017 American Association of Physicists in Medicine.

  10. An evaluation of the economics and logistics of animal mortality composting for the Virginia Department of Transportation.

    DOT National Transportation Integrated Search

    2015-04-01

    Many maintenance facilities of the Virginia Department of Transportation (VDOT) face a decreasing availability of the : conventional methods of animal mortality disposal (i.e., landfills and burial of individual mortalities) and have a need for a via...

  11. Development and evaluation of a simplified superpave IDT testing system for implementation in mix design and control : final report, March 2008.

    DOT National Transportation Integrated Search

    2009-08-01

    Asphalt mixtures designed using modern conventional methods, whether Marshall or Superpave methodologies, fail to address the cracking performance of these mixtures. Research previously conducted at the University of Florida for the Florida Departmen...

  12. Single Wall Carbon Nanotube Alignment Mechanisms for Non-Destructive Evaluation

    NASA Technical Reports Server (NTRS)

    Hong, Seunghun

    2002-01-01

    As proposed in our original proposal, we developed a new innovative method to assemble millions of single wall carbon nanotube (SWCNT)-based circuit components as fast as conventional microfabrication processes. This method is based on surface template assembly strategy. The new method solves one of the major bottlenecks in carbon nanotube based electrical applications and, potentially, may allow us to mass produce a large number of SWCNT-based integrated devices of critical interests to NASA.

  13. Rapid Prototyping: A Survey and Evaluation of Methodologies and Models

    DTIC Science & Technology

    1990-03-01

    possibility of program coding errors or design differences from the actual prototype the user validated. The method - ology should result in a production...behavior within the problem domain to be defned. "Each method has a different approach towards developing the set of symbols with which to define the...investigate prototyping as a viable alternative to the conventional method of software development. By the mid 1980’s, it was evi- dent that the traditional

  14. Improved magnetic resonance fingerprinting reconstruction with low-rank and subspace modeling.

    PubMed

    Zhao, Bo; Setsompop, Kawin; Adalsteinsson, Elfar; Gagoski, Borjan; Ye, Huihui; Ma, Dan; Jiang, Yun; Ellen Grant, P; Griswold, Mark A; Wald, Lawrence L

    2018-02-01

    This article introduces a constrained imaging method based on low-rank and subspace modeling to improve the accuracy and speed of MR fingerprinting (MRF). A new model-based imaging method is developed for MRF to reconstruct high-quality time-series images and accurate tissue parameter maps (e.g., T 1 , T 2 , and spin density maps). Specifically, the proposed method exploits low-rank approximations of MRF time-series images, and further enforces temporal subspace constraints to capture magnetization dynamics. This allows the time-series image reconstruction problem to be formulated as a simple linear least-squares problem, which enables efficient computation. After image reconstruction, tissue parameter maps are estimated via dictionary-based pattern matching, as in the conventional approach. The effectiveness of the proposed method was evaluated with in vivo experiments. Compared with the conventional MRF reconstruction, the proposed method reconstructs time-series images with significantly reduced aliasing artifacts and noise contamination. Although the conventional approach exhibits some robustness to these corruptions, the improved time-series image reconstruction in turn provides more accurate tissue parameter maps. The improvement is pronounced especially when the acquisition time becomes short. The proposed method significantly improves the accuracy of MRF, and also reduces data acquisition time. Magn Reson Med 79:933-942, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  15. Using a fuzzy comprehensive evaluation method to determine product usability: A test case.

    PubMed

    Zhou, Ronggang; Chan, Alan H S

    2017-01-01

    In order to take into account the inherent uncertainties during product usability evaluation, Zhou and Chan [1] proposed a comprehensive method of usability evaluation for products by combining the analytic hierarchy process (AHP) and fuzzy evaluation methods for synthesizing performance data and subjective response data. This method was designed to provide an integrated framework combining the inevitable vague judgments from the multiple stages of the product evaluation process. In order to illustrate the effectiveness of the model, this study used a summative usability test case to assess the application and strength of the general fuzzy usability framework. To test the proposed fuzzy usability evaluation framework [1], a standard summative usability test was conducted to benchmark the overall usability of a specific network management software. Based on the test data, the fuzzy method was applied to incorporate both the usability scores and uncertainties involved in the multiple components of the evaluation. Then, with Monte Carlo simulation procedures, confidence intervals were used to compare the reliabilities among the fuzzy approach and two typical conventional methods combining metrics based on percentages. This case study showed that the fuzzy evaluation technique can be applied successfully for combining summative usability testing data to achieve an overall usability quality for the network software evaluated. Greater differences of confidence interval widths between the method of averaging equally percentage and weighted evaluation method, including the method of weighted percentage averages, verified the strength of the fuzzy method.

  16. Accuracy of limited four-slice CT-scan in diagnosis of chronic rhinosinusitis.

    PubMed

    Zojaji, R; Nekooei, S; Naghibi, S; Mazloum Farsi Baf, M; Jalilian, R; Masoomi, M

    2015-12-01

    Chronic rhinosinusitis (CRS) is a common chronic health condition worldwide. Standard CT-scan is the method of choice for diagnosis of CRS but its high price and considerable radiation exposure have limited its application. The main goal of this study was to evaluate the accuracy of limited four-slice coronal CT-scan in the diagnosis of CRS. This cross-sectional study was conducted on 46 patients with CRS, for one year, based on American Society of Head and Neck Surgery criteria. All patients received the preoperative standard and four-slice CT-scans, after which endoscopic sinus surgery was performed. Findings of four-slice CT-scans were compared with those of conventional CT-scan and the sensitivity and specificity of four-slice CT-scan and its agreement with conventional CT-scan was calculated. In this study, 46 patients including 32 males (69.6%) and 14 females (30.46%) with a mean age of 33 and standard deviation of 9 years, were evaluated. Sensitivity and specificity of four-slice CT-scan were 97.5% and 100%, respectively. Also, positive predictive value (PPV) and negative predictive value (NPV) of four-slice CT was 100% and 85.71%, respectively. There was a strong agreement between four-slice CT and conventional CT findings. Considering the high sensitivity and specificity of four-slice CT-scan and strong agreement with conventional CT-scan in the diagnosis of CRS and the lower radiation exposure and cost, application of this method is suggested for both diagnosis and treatment follow-up in CRS. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. Improved automated lumen contour detection by novel multifrequency processing algorithm with current intravascular ultrasound system.

    PubMed

    Kume, Teruyoshi; Kim, Byeong-Keuk; Waseda, Katsuhisa; Sathyanarayana, Shashidhar; Li, Wenguang; Teo, Tat-Jin; Yock, Paul G; Fitzgerald, Peter J; Honda, Yasuhiro

    2013-02-01

    The aim of this study was to evaluate a new fully automated lumen border tracing system based on a novel multifrequency processing algorithm. We developed the multifrequency processing method to enhance arterial lumen detection by exploiting the differential scattering characteristics of blood and arterial tissue. The implementation of the method can be integrated into current intravascular ultrasound (IVUS) hardware. This study was performed in vivo with conventional 40-MHz IVUS catheters (Atlantis SR Pro™, Boston Scientific Corp, Natick, MA) in 43 clinical patients with coronary artery disease. A total of 522 frames were randomly selected, and lumen areas were measured after automatically tracing lumen borders with the new tracing system and a commercially available tracing system (TraceAssist™) referred to as the "conventional tracing system." The data assessed by the two automated systems were compared with the results of manual tracings by experienced IVUS analysts. New automated lumen measurements showed better agreement with manual lumen area tracings compared with those of the conventional tracing system (correlation coefficient: 0.819 vs. 0.509). When compared against manual tracings, the new algorithm also demonstrated improved systematic error (mean difference: 0.13 vs. -1.02 mm(2) ) and random variability (standard deviation of difference: 2.21 vs. 4.02 mm(2) ) compared with the conventional tracing system. This preliminary study showed that the novel fully automated tracing system based on the multifrequency processing algorithm can provide more accurate lumen border detection than current automated tracing systems and thus, offer a more reliable quantitative evaluation of lumen geometry. Copyright © 2011 Wiley Periodicals, Inc.

  18. Reversing the conventional leather processing sequence for cleaner leather production.

    PubMed

    Saravanabhavan, Subramani; Thanikaivelan, Palanisamy; Rao, Jonnalagadda Raghava; Nair, Balachandran Unni; Ramasami, Thirumalachari

    2006-02-01

    Conventional leather processing generally involves a combination of single and multistep processes that employs as well as expels various biological, inorganic, and organic materials. It involves nearly 14-15 steps and discharges a huge amount of pollutants. This is primarily due to the fact that conventional leather processing employs a "do-undo" process logic. In this study, the conventional leather processing steps have been reversed to overcome the problems associated with the conventional method. The charges of the skin matrix and of the chemicals and pH profiles of the process have been judiciously used for reversing the process steps. This reversed process eventually avoids several acidification and basification/neutralization steps used in conventional leather processing. The developed process has been validated through various analyses such as chromium content, shrinkage temperature, softness measurements, scanning electron microscopy, and physical testing of the leathers. Further, the performance of the leathers is shown to be on par with conventionally processed leathers through bulk property evaluation. The process enjoys a significant reduction in COD and TS by 53 and 79%, respectively. Water consumption and discharge is reduced by 65 and 64%, respectively. Also, the process benefits from significant reduction in chemicals, time, power, and cost compared to the conventional process.

  19. a New Multi-Spectral Threshold Normalized Difference Water Index Mst-Ndwi Water Extraction Method - a Case Study in Yanhe Watershed

    NASA Astrophysics Data System (ADS)

    Zhou, Y.; Zhao, H.; Hao, H.; Wang, C.

    2018-05-01

    Accurate remote sensing water extraction is one of the primary tasks of watershed ecological environment study. Since the Yanhe water system has typical characteristics of a small water volume and narrow river channel, which leads to the difficulty for conventional water extraction methods such as Normalized Difference Water Index (NDWI). A new Multi-Spectral Threshold segmentation of the NDWI (MST-NDWI) water extraction method is proposed to achieve the accurate water extraction in Yanhe watershed. In the MST-NDWI method, the spectral characteristics of water bodies and typical backgrounds on the Landsat/TM images have been evaluated in Yanhe watershed. The multi-spectral thresholds (TM1, TM4, TM5) based on maximum-likelihood have been utilized before NDWI water extraction to realize segmentation for a division of built-up lands and small linear rivers. With the proposed method, a water map is extracted from the Landsat/TM images in 2010 in China. An accuracy assessment is conducted to compare the proposed method with the conventional water indexes such as NDWI, Modified NDWI (MNDWI), Enhanced Water Index (EWI), and Automated Water Extraction Index (AWEI). The result shows that the MST-NDWI method generates better water extraction accuracy in Yanhe watershed and can effectively diminish the confusing background objects compared to the conventional water indexes. The MST-NDWI method integrates NDWI and Multi-Spectral Threshold segmentation algorithms, with richer valuable information and remarkable results in accurate water extraction in Yanhe watershed.

  20. Feasibility of two-dimensional speckle tracking in evaluation of arterial stiffness: Comparison with pulse wave velocity and conventional sonographic markers of atherosclerosis.

    PubMed

    Podgórski, Michał; Grzelak, Piotr; Kaczmarska, Magdalena; Polguj, Michał; Łukaszewski, Maciej; Stefańczyk, Ludomir

    2018-02-01

    Objective Arterial stiffening is an early marker of atherosclerosis that has a prognostic value for cardiovascular morbidity and mortality. Although many markers of arterial hardening have been proposed, the search is on for newer, more user-friendly and reliable surrogates. One such potential candidate has emerged from cardiology, the speckle-tracking technique. The aim of this study was to evaluate the feasibility of the two-dimensional speckle tracking for the evaluation of arterial wall stiffness in comparison with standard stiffness parameters. Methods Carotid ultrasound and applanation tonometry were performed in 188 patients with no cardiovascular risk factors. The following parameters were then evaluated: the intima-media complex thickness, distensibility coefficient, β-stiffness index, circumferential strain/strain rate, and pulse wave velocity and augmentation index. These variables were compared with each other and with patient age, and their reliability was assessed with Bland-Altman plots. Results Strain parameters derived from two-dimensional speckle tracking and intima-media complex thickness correlated better with age and pulse wave velocity than standard makers of arterial stiffness. Moreover, the reliability of these measurements was significantly higher than conventional surrogates. Conclusions Two-dimensional speckle tracing is a reliable method for the evaluation of arterial stiffness. Therefore, together with intima-media complex thickness measurement, it offers great potential in clinical practice as an early marker of atherosclerosis.

  1. A Stereological Method for the Quantitative Evaluation of Cartilage Repair Tissue

    PubMed Central

    Nyengaard, Jens Randel; Lind, Martin; Spector, Myron

    2015-01-01

    Objective To implement stereological principles to develop an easy applicable algorithm for unbiased and quantitative evaluation of cartilage repair. Design Design-unbiased sampling was performed by systematically sectioning the defect perpendicular to the joint surface in parallel planes providing 7 to 10 hematoxylin–eosin stained histological sections. Counting windows were systematically selected and converted into image files (40-50 per defect). The quantification was performed by two-step point counting: (1) calculation of defect volume and (2) quantitative analysis of tissue composition. Step 2 was performed by assigning each point to one of the following categories based on validated and easy distinguishable morphological characteristics: (1) hyaline cartilage (rounded cells in lacunae in hyaline matrix), (2) fibrocartilage (rounded cells in lacunae in fibrous matrix), (3) fibrous tissue (elongated cells in fibrous tissue), (4) bone, (5) scaffold material, and (6) others. The ability to discriminate between the tissue types was determined using conventional or polarized light microscopy, and the interobserver variability was evaluated. Results We describe the application of the stereological method. In the example, we assessed the defect repair tissue volume to be 4.4 mm3 (CE = 0.01). The tissue fractions were subsequently evaluated. Polarized light illumination of the slides improved discrimination between hyaline cartilage and fibrocartilage and increased the interobserver agreement compared with conventional transmitted light. Conclusion We have applied a design-unbiased method for quantitative evaluation of cartilage repair, and we propose this algorithm as a natural supplement to existing descriptive semiquantitative scoring systems. We also propose that polarized light is effective for discrimination between hyaline cartilage and fibrocartilage. PMID:26069715

  2. A Stereological Method for the Quantitative Evaluation of Cartilage Repair Tissue.

    PubMed

    Foldager, Casper Bindzus; Nyengaard, Jens Randel; Lind, Martin; Spector, Myron

    2015-04-01

    To implement stereological principles to develop an easy applicable algorithm for unbiased and quantitative evaluation of cartilage repair. Design-unbiased sampling was performed by systematically sectioning the defect perpendicular to the joint surface in parallel planes providing 7 to 10 hematoxylin-eosin stained histological sections. Counting windows were systematically selected and converted into image files (40-50 per defect). The quantification was performed by two-step point counting: (1) calculation of defect volume and (2) quantitative analysis of tissue composition. Step 2 was performed by assigning each point to one of the following categories based on validated and easy distinguishable morphological characteristics: (1) hyaline cartilage (rounded cells in lacunae in hyaline matrix), (2) fibrocartilage (rounded cells in lacunae in fibrous matrix), (3) fibrous tissue (elongated cells in fibrous tissue), (4) bone, (5) scaffold material, and (6) others. The ability to discriminate between the tissue types was determined using conventional or polarized light microscopy, and the interobserver variability was evaluated. We describe the application of the stereological method. In the example, we assessed the defect repair tissue volume to be 4.4 mm(3) (CE = 0.01). The tissue fractions were subsequently evaluated. Polarized light illumination of the slides improved discrimination between hyaline cartilage and fibrocartilage and increased the interobserver agreement compared with conventional transmitted light. We have applied a design-unbiased method for quantitative evaluation of cartilage repair, and we propose this algorithm as a natural supplement to existing descriptive semiquantitative scoring systems. We also propose that polarized light is effective for discrimination between hyaline cartilage and fibrocartilage.

  3. [Surface characteristics of the acrylic resins according to the polishing methods].

    PubMed

    Vitalariu, Anca Mihaela; Lazăr, Lenuţa; Buruiană, Tinca; Diaconu, Diana; Tatarciuc, Monica Silvia

    2011-01-01

    The objective of this study was to evaluate the effect of the polishing technique and glazing on the porosity of the dental resins. The studied resins were: Castapress/Vertex, Prothyl Hot/Zermack, Rapid Simplified/Vertex, Duracryl Plus/Spofa Dental, Vertex-Soft/Vertex, Superacryl Plus/Spofa Dental. Thirty specimens, five for every resin, of 50/25/2 cm in size were done. One surface of each sample was polished with extrahard tungsten carbide burs, the other surface being polished with extrahard extrafine and diamond burs. The final polishing was done using a conventional method: pumice, water and lathe bristle brush for 90 seconds, 1500 rpm and soft leather polishing wheel for 90 seconds, 3000 rpm. Twenty surfaces were glazed after polishing with Glaze/Bosworth. Vertex Soft specimens were not polished because this is a resilient material. Surface porosity of the acrylic resin specimens was measured by optical microscopy. The lowest porosity was obtained by conventional polishing combined with glazing techniques. No differences between glazed and non/glazed self-curing resin specimens were noticed, but there were differences between self-curing and heat-curing resins. Conventional lathe polishing method is an effective and reliable technique for polishing dental resins. Specimens of self-curing resin had a higher porosity than heat curing resin following the same surface treatment. Higher surface smoothness was obtained by conventional lathe polishing completed by glazing.

  4. Natural leathers from natural materials: progressing toward a new arena in leather processing.

    PubMed

    Saravanabhavan, Subramani; Thanikaivelan, Palanisamy; Rao, Jonnalagadda Raghava; Nair, Balachandran Unni; Ramasami, Thirumalachari

    2004-02-01

    Globally, the leather industry is currently undergoing radical transformation due to pollution and discharge legislations. Thus, the leather industry is pressurized to look for cleaner options for processing the raw hides and skins. Conventional methods of pre-tanning, tanning and post-tanning processes are known to contribute more than 98% of the total pollution load from the leather processing. The conventional method of the tanning process involves the "do-undo" principle. Furthermore, the conventional methods employed in leather processing subject the skin/ hide to a wide variation in pH (2.8-13.0). This results in the emission of huge amounts of pollution loads such as BOD, COD, TDS, TS, sulfates, chlorides and chromium. In the approach illustrated here, the hair and flesh removal as well as fiber opening have been achieved using biocatalysts at pH 8.0, pickle-free natural tanning employing vegetable tannins, and post-tanning using environmentally friendly chemicals. Hence, this process involves dehairing, fiber opening, and pickle-free natural tanning followed by ecofriendly post-tanning. It has been found that the extent of hair removal and opening up of fiber bundles is comparable to that of conventionally processed leathers. This has been substantiated through scanning electron microscopic analysis and softness measurements. Performance of the leathers is shown to be on par with conventionally chrome-tanned leathers through physical and hand evaluation. The process also exhibits zero metal (chromium) discharge and significant reduction in BOD, COD, TDS, and TS loads by 83, 69, 96, and 96%, respectively. Furthermore, the developed process seems to be economically viable.

  5. A novel test cage with an air ventilation system as an alternative to conventional cages for the efficacy testing of mosquito repellents.

    PubMed

    Obermayr, U; Rose, A; Geier, M

    2010-11-01

    We have developed a novel test cage and improved method for the evaluation of mosquito repellents. The method is compatible with the United States Environmental Protection Agency, 2000 draft OPPTS 810.3700 Product Performance Test Guidelines for Testing of Insect Repellents. The Biogents cages (BG-cages) require fewer test mosquitoes than conventional cages and are more comfortable for the human volunteers. The novel cage allows a section of treated forearm from a volunteer to be exposed to mosquito probing through a window. This design minimizes residual contamination of cage surfaces with repellent. In addition, an air ventilation system supplies conditioned air to the cages after each single test, to flush out and prevent any accumulation of test substances. During biting activity tests, the untreated skin surface does not receive bites because of a screen placed 150 mm above the skin. Compared with the OPPTS 810.3700 method, the BG-cage is smaller (27 liters, compared with 56 liters) and contains 30 rather than hundreds of blood-hungry female mosquitoes. We compared the performance of a proprietary repellent formulation containing 20% KBR3023 with four volunteers on Aedes aegypti (L.) (Diptera: Culicidae) in BG- and conventional cages. Repellent protection time was shorter in tests conducted with conventional cages. The average 95% protection time was 4.5 +/- 0.4 h in conventional cages and 7.5 +/- 0.6 h in the novel BG-cages. The protection times measured in BG-cages were more similar to the protection times determined with these repellents in field tests.

  6. Improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography

    PubMed Central

    Liu, Mei-Juan; Men, Yan-Ming; Zhang, Yong-Lin; Zhang, Yu-Xi; Liu, Hao

    2017-01-01

    We aimed to evaluate the diagnostic values of conventional ultrasound (US), ultrasound contrast (UC) and ultrasound elastography (UE) in distinguishing the benign and malignant thyroid nodules. A total of 100 patients with thyroid nodules receiving operative treatment were selected; they underwent the conventional US, UE and UC examinations before operation, respectively. The nodules received pathological examination after operation to distinguish benign from malignant lesions. The sensitivity, specificity and diagnostic accordance rate of each diagnostic method was evaluated by receiver operating characteristic (ROC) curve, and the area under the curve (AUC) of ROC was calculated. The manifestations of malignant thyroid nodules in conventional US examination were mostly the hypoecho, heterogeneous echo, irregular shape, unclear boundary, aspect ratio <1, microcalcification and irregular peripheral echo halo, and there were statistically significant differences compared with the benign nodules (P<0.05). UE showed that the differences between benign and malignant nodules in 2, 3 and 4 points were statistically significant (P<0.05). The manifestations of malignant nodules in UC were mostly the irregular shape, obscure boundary, no obvious enhancement, heterogeneous enhancement and visible perfusion defects, and there were statistically significant differences compared with the benign nodules (P<0.05). ROC curve showed that both sensitivity and specificity of UE and UC were superior to those of conventional US. AUC was the largest (AUC = 0.908) and the diagnostic value was the highest in the conventional US combined with UE and UC. Conventional US combined with elastography and UC can significantly improve the sensitivity, specificity and accuracy of diagnosis of benign and malignant thyroid nodules. PMID:28693244

  7. Improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography.

    PubMed

    Liu, Mei-Juan; Men, Yan-Ming; Zhang, Yong-Lin; Zhang, Yu-Xi; Liu, Hao

    2017-07-01

    We aimed to evaluate the diagnostic values of conventional ultrasound (US), ultrasound contrast (UC) and ultrasound elastography (UE) in distinguishing the benign and malignant thyroid nodules. A total of 100 patients with thyroid nodules receiving operative treatment were selected; they underwent the conventional US, UE and UC examinations before operation, respectively. The nodules received pathological examination after operation to distinguish benign from malignant lesions. The sensitivity, specificity and diagnostic accordance rate of each diagnostic method was evaluated by receiver operating characteristic (ROC) curve, and the area under the curve (AUC) of ROC was calculated. The manifestations of malignant thyroid nodules in conventional US examination were mostly the hypoecho, heterogeneous echo, irregular shape, unclear boundary, aspect ratio <1, microcalcification and irregular peripheral echo halo, and there were statistically significant differences compared with the benign nodules (P<0.05). UE showed that the differences between benign and malignant nodules in 2, 3 and 4 points were statistically significant (P<0.05). The manifestations of malignant nodules in UC were mostly the irregular shape, obscure boundary, no obvious enhancement, heterogeneous enhancement and visible perfusion defects, and there were statistically significant differences compared with the benign nodules (P<0.05). ROC curve showed that both sensitivity and specificity of UE and UC were superior to those of conventional US. AUC was the largest (AUC = 0.908) and the diagnostic value was the highest in the conventional US combined with UE and UC. Conventional US combined with elastography and UC can significantly improve the sensitivity, specificity and accuracy of diagnosis of benign and malignant thyroid nodules.

  8. Influence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study.

    PubMed

    Pereira, Graziane Olímpio; Gimenez, Carla Maria Melleiro; Prieto, Lucas; Prieto, Marcos Gabriel do Lago; Basting, Roberta Tarkany

    2016-01-01

    To evaluate stainless steel archwire static friction in active and passive self-ligating lingual and conventional brackets with second-order angulations. Two conventional lingual brackets for canines (STb light/Ormco; PSWb/Tecnident), and two self-ligating brackets, one active (In-Ovation L/GAC) and the other passive (3D/ Forestadent), were evaluated. A stainless steel archwire was used at 0°, 3° and 5° angulations. Metal ligatures, conventional elastic ligatures, and low friction elastic ligatures were also tested. A universal testing machine applied friction between brackets and wires, simulating sliding mechanics, to produce 2-mm sliding at 3 mm/minute speed. Two-way analysis of variance demonstrated a significant effect of the interaction between brackets and angulations (p < 0.001). Tukey test indicated that the highest frictional resistance values were observed at 5° angulation for In-Ovation L, PSWb bracket with non conventional ligature, and STb bracket with metal ligature. As for 3D, PSWb with conventional or metal ligatures, and STb brackets with non conventional ligature, showed significantly lower static frictional resistance with 0° angulation. At 0° angulation, STb brackets with metal ties, In-Ovation L brackets and 3D brackets had the lowest frictional resistance. As the angulation increased from 0° to 3°, static friction resistance increased. When angulation increased from 3° to 5°, static friction resistance increased or remained the same. Self-ligating 3D and In-Ovation L brackets, as well as conventional STb brackets, seem to be the best option when sliding mechanics is used to perform lingual orthodontic treatment.

  9. Evaluating Quality of Aged Archival Formalin-Fixed Paraffin-Embedded Samples for RNA-Sequencing

    EPA Science Inventory

    Archival formalin-fixed paraffin-embedded (FFPE) samples offer a vast, untapped source of genomic data for biomarker discovery. However, the quality of FFPE samples is often highly variable, and conventional methods to assess RNA quality for RNA-sequencing (RNA-seq) are not infor...

  10. Comparison of Pictorial Techniques for Guiding Performance During Training.

    ERIC Educational Resources Information Center

    Miller, Elmo E.

    An experimental program was conducted to develop effective methods for producing and utilizing filmed demonstrations and instructional manuals. Four variations on conventional filmed demonstrations were evaluated: 1) revising an Army film through repeated tryouts with novices, 2) stopping the projector after each step is demonstrated to allow…

  11. Passive Sampling in Regulatory Chemical Monitoring of Nonpolar Organic Compounds in the Aquatic Environment

    EPA Science Inventory

    We reviewed compliance monitoring requirements in the European Union (EU), the United States(USA), and the Oslo-Paris Convention for the protection of the marine environment of the North-East Atlantic (OSPAR), and evaluated if these are met by passive sampling methods for nonpola...

  12. Critical Evaluation of Air-Liquid Interface Cell Exposure Systems for In Vitro Assessment of Atmospheric Pollutants##

    EPA Science Inventory

    Conventional in vitro exposure studies of airborne pollutants involve, for example, the addition of particulate matter (PM) or PM extracts to the cell culture medium, or the bubbling of gases into the culture medium; these methods alter the pollutant’s physical and chemical...

  13. A Comparative Study to Evaluate the Functional Effect of Unilateral Uvuloplasty after Primary Palatoplasty

    PubMed Central

    Olivencia-Flores, Claudia; Gavino-Gutierrez, Arquímedes M.; Caceres-Nano, Evelyn; Cotrina-Rabanal, Omar

    2015-01-01

    Background: The conventional method for uvular repair suturing the 2 hemi-uvulas of the palatal cleft together in the midline does not allow us to obtain a proper anatomical repair. In our hands, the midline straight closure frequently causes retraction of the uvular tissues with the consequent abnormal appearance of the uvula. We described before a method for uvular repair in patients with cleft palate. The technique consists in preserving one of the hemi-uvulas, which is moved to the midline to form the definitive uvula. The purpose of this study was to evaluate the functional effects of the unilateral uvuloplasty for uvular repair in a group of patients with bilateral cleft palate. Methods: This is a retrospective, single-blinded cohort study between 2 groups of 90 patients with bilateral cleft palate who were operated on using the conventional and unilateral uvuloplasty methods of uvular repair from 2000 to 2009. Data collection was accomplished by physical examination to evaluate the presence of postoperative fistulas and hypernasal speech determined at 6 months to 5 years after surgery. In addition, postoperative dimensions of the velopharynx were measured by a single-blind examiner using a computed tomography scan. Results: Our comparative study found statistically significant differences between the 2 groups in favor of the unilateral uvuloplasty group. Conclusions: We observed that the use of unilateral uvuloplasty for uvular reconstruction reduces the velopharyngeal space and the frequency of hypernasality in patients with bilateral cleft palate. PMID:26180716

  14. Accurate evaluation of exchange fields in finite element micromagnetic solvers

    NASA Astrophysics Data System (ADS)

    Chang, R.; Escobar, M. A.; Li, S.; Lubarda, M. V.; Lomakin, V.

    2012-04-01

    Quadratic basis functions (QBFs) are implemented for solving the Landau-Lifshitz-Gilbert equation via the finite element method. This involves the introduction of a set of special testing functions compatible with the QBFs for evaluating the Laplacian operator. The results by using QBFs are significantly more accurate than those via linear basis functions. QBF approach leads to significantly more accurate results than conventionally used approaches based on linear basis functions. Importantly QBFs allow reducing the error of computing the exchange field by increasing the mesh density for structured and unstructured meshes. Numerical examples demonstrate the feasibility of the method.

  15. Assessing the Potential Use of Eye-Tracking Triangulation for Evaluating the Usability of an Online Diabetes Exercise System.

    PubMed

    Schaarup, Clara; Hartvigsen, Gunnar; Larsen, Lars Bo; Tan, Zheng-Hua; Årsand, Eirik; Hejlesen, Ole Kristian

    2015-01-01

    The Online Diabetes Exercise System was developed to motivate people with Type 2 diabetes to do a 25 minutes low-volume high-intensity interval training program. In a previous multi-method evaluation of the system, several usability issues were identified and corrected. Despite the thorough testing, it was unclear whether all usability problems had been identified using the multi-method evaluation. Our hypothesis was that adding the eye-tracking triangulation to the multi-method evaluation would increase the accuracy and completeness when testing the usability of the system. The study design was an Eye-tracking Triangulation; conventional eye-tracking with predefined tasks followed by The Post-Experience Eye-Tracked Protocol (PEEP). Six Areas of Interests were the basis for the PEEP-session. The eye-tracking triangulation gave objective and subjective results, which are believed to be highly relevant for designing, implementing, evaluating and optimizing systems in the field of health informatics. Future work should include testing the method on a larger and more representative group of users and apply the method on different system types.

  16. 3D Ultrasonic Non-destructive Evaluation of Spot Welds Using an Enhanced Total Focusing Method

    NASA Astrophysics Data System (ADS)

    Jasiuniene, Elena; Samaitis, Vykintas; Mazeika, Liudas; Sanderson, Ruth

    2015-02-01

    Spot welds are used to join sheets of metals in the automotive industry. When spot weld quality is evaluated using conventional ultrasonic manual pulse-echo method, the reliability of the inspection is affected by selection of the probe diameter and the positioning of the probe in the weld center. The application of a 2D matrix array is a potential solution to the aforementioned problems. The objective of this work was to develop a signal processing algorithm to reconstruct the 3D spot weld volume showing the size of the nugget and the defects in it. In order to achieve this, the conventional total focusing method was enhanced by taking into account the directivities of the single elements of the array and the divergence of the ultrasonic beam due to the propagation distance. Enhancements enabled a reduction in the background noise and uniform sensitivity at different depths to be obtained. The proposed algorithm was verified using a finite element model of ultrasonic wave propagation simulating three common spot weld conditions: a good weld, an undersized weld, and a weld containing a pore. The investigations have demonstrated that proposed method enables the determination of the size of the nugget and detection of discontinuities.

  17. Assessment of flood susceptible areas using spatially explicit, probabilistic multi-criteria decision analysis

    NASA Astrophysics Data System (ADS)

    Tang, Zhongqian; Zhang, Hua; Yi, Shanzhen; Xiao, Yangfan

    2018-03-01

    GIS-based multi-criteria decision analysis (MCDA) is increasingly used to support flood risk assessment. However, conventional GIS-MCDA methods fail to adequately represent spatial variability and are accompanied with considerable uncertainty. It is, thus, important to incorporate spatial variability and uncertainty into GIS-based decision analysis procedures. This research develops a spatially explicit, probabilistic GIS-MCDA approach for the delineation of potentially flood susceptible areas. The approach integrates the probabilistic and the local ordered weighted averaging (OWA) methods via Monte Carlo simulation, to take into account the uncertainty related to criteria weights, spatial heterogeneity of preferences and the risk attitude of the analyst. The approach is applied to a pilot study for the Gucheng County, central China, heavily affected by the hazardous 2012 flood. A GIS database of six geomorphological and hydrometeorological factors for the evaluation of susceptibility was created. Moreover, uncertainty and sensitivity analysis were performed to investigate the robustness of the model. The results indicate that the ensemble method improves the robustness of the model outcomes with respect to variation in criteria weights and identifies which criteria weights are most responsible for the variability of model outcomes. Therefore, the proposed approach is an improvement over the conventional deterministic method and can provides a more rational, objective and unbiased tool for flood susceptibility evaluation.

  18. Applications of copolymer for rapid identification of bacteria in blood culture broths using matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

    PubMed

    Ashizawa, Kazuho; Murata, Syota; Terada, Takashi; Ito, Daisuke; Bunya, Masaru; Watanabe, Koji; Teruuchi, Yoko; Tsuchida, Sachio; Satoh, Mamoru; Nishimura, Motoi; Matsushita, Kazuyuki; Sugama, Yuji; Nomura, Fumio

    2017-08-01

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) can be used to identify pathogens in blood culture samples. However, sample pretreatment is needed for direct identification of microbes in blood culture bottles. Conventional protocols are complex and time-consuming. Therefore, in this study, we developed a method for collecting bacteria using polyallylamine-polystyrene copolymer for application in wastewater treatment technology. Using representative bacterial species Escherichia coli and Staphylococcus capitis, we found that polyallylamine-polystyrene can form visible aggregates with bacteria, which can be identified using MALDI-TOF MS. The processing time of our protocol was as short as 15min. Hemoglobin interference in MALDI spectra analysis was significantly decreased in our method compared with the conventional method. In a preliminary experiment, we evaluated the use of our protocol to identify clinical isolates from blood culture bottles. MALDI-TOF MS-based identification of 17 strains from five bacterial species (E. coli, Klebsiella pneumoniae, Enterococcus faecalis, S. aureus, and S. capitis) collected by our protocol was satisfactory. Prospective large-scale studies are needed to further evaluate the clinical application of this novel and simple method of collecting bacteria in blood culture bottles. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Clinical evaluation of β-tubulin real-time PCR for rapid diagnosis of dermatophytosis, a comparison with mycological methods.

    PubMed

    Motamedi, Marjan; Mirhendi, Hossein; Zomorodian, Kamiar; Khodadadi, Hossein; Kharazi, Mahboobeh; Ghasemi, Zeinab; Shidfar, Mohammad Reza; Makimura, Koichi

    2017-10-01

    Following our previous report on evaluation of the beta tubulin real-time PCR for detection of dermatophytosis, this study aimed to compare the real-time PCR assay with conventional methods for the clinical assessment of its diagnostic performance. Samples from a total of 853 patients with suspected dermatophyte lesions were subjected to direct examination (all samples), culture (499 samples) and real-time PCR (all samples). Fungal DNA was extracted directly from clinical samples using a conical steel bullet, followed by purification with a commercial kit and subjected to the Taq-Man probe-based real-time PCR. The study showed that among the 499 specimens for which all three methods were used, 156 (31.2%), 128 (25.6%) and 205 (41.0%) were found to be positive by direct microscopy, culture and real-time PCR respectively. Real-time PCR significantly increased the detection rate of dermatophytes compared with microscopy (288 vs 229) with 87% concordance between the two methods. The sensitivity, specificity, positive predictive value, and negative predictive value of the real-time PCR was 87.5%, 85%, 66.5% and 95.2% respectively. Although real-time PCR performed better on skin than on nail samples, it should not yet fully replace conventional diagnosis. © 2017 Blackwell Verlag GmbH.

  20. Supervised exercises for adults with acute lateral ankle sprain: a randomised controlled trial

    PubMed Central

    van Rijn, Rogier M; van Os, Anton G; Kleinrensink, Gert-Jan; Bernsen, Roos MD; Verhaar, Jan AN; Koes, Bart W; Bierma-Zeinstra, Sita MA

    2007-01-01

    Background During the recovery period after acute ankle sprain, it is unclear whether conventional treatment should be supported by supervised exercise. Aim To evaluate the short- and long-term effectiveness of conventional treatment combined with supervised exercises compared with conventional treatment alone in patients with an acute ankle sprain. Design Randomised controlled clinical trial. Setting A total of 32 Dutch general practices and the hospital emergency department. Method Adults with an acute lateral ankle sprain consulting general practices or the hospital emergency department were allocated to either conventional treatment combined with supervised exercises or conventional treatment alone. Primary outcomes were subjective recovery (0–10 point scale) and the occurrence of a re-sprain. Measurements were carried out at intake, 4 weeks, 8 weeks, 3 months, and 1 year after injury. Data were analysed using intention-to-treat analyses. Results A total of 102 patients were enrolled and randomised to either conventional treatment alone or conventional treatment combined with supervised exercise. There was no significant difference between treatment groups concerning subjective recovery or occurrence of re-sprains after 3 months and 1-year of follow-up. Conclusion Conventional treatment combined with supervised exercises compared to conventional treatment alone during the first year after an acute lateral ankle sprain does not lead to differences in the occurrence of re-sprains or in subjective recovery. PMID:17925136

  1. Cation solvation with quantum chemical effects modeled by a size-consistent multi-partitioning quantum mechanics/molecular mechanics method.

    PubMed

    Watanabe, Hiroshi C; Kubillus, Maximilian; Kubař, Tomáš; Stach, Robert; Mizaikoff, Boris; Ishikita, Hiroshi

    2017-07-21

    In the condensed phase, quantum chemical properties such as many-body effects and intermolecular charge fluctuations are critical determinants of the solvation structure and dynamics. Thus, a quantum mechanical (QM) molecular description is required for both solute and solvent to incorporate these properties. However, it is challenging to conduct molecular dynamics (MD) simulations for condensed systems of sufficient scale when adapting QM potentials. To overcome this problem, we recently developed the size-consistent multi-partitioning (SCMP) quantum mechanics/molecular mechanics (QM/MM) method and realized stable and accurate MD simulations, using the QM potential to a benchmark system. In the present study, as the first application of the SCMP method, we have investigated the structures and dynamics of Na + , K + , and Ca 2+ solutions based on nanosecond-scale sampling, a sampling 100-times longer than that of conventional QM-based samplings. Furthermore, we have evaluated two dynamic properties, the diffusion coefficient and difference spectra, with high statistical certainty. Furthermore the calculation of these properties has not previously been possible within the conventional QM/MM framework. Based on our analysis, we have quantitatively evaluated the quantum chemical solvation effects, which show distinct differences between the cations.

  2. Radionuclide evaluation of left ventricular function with nonimaging probes.

    PubMed

    Wexler, J P; Blaufox, M D

    1979-10-01

    Portable nonimaging probes have been developed that can evaluate left ventricular function using radionuclide techniques. Two modes of data acquisition are possible with these probe systems, first-pass and gated. Precordial radiocardiograms obtained after a bolus injection can be used to determine cardiac output, pulmonary transit time, pulmonary blood volume, left ventricle ejection fraction, and left-to-right shunts. Gated techniques can be used to determine left ventricular ejection fraction and sytolic time intervals. Probe-determined indices of left ventricular function agree excellently with comparable measurements determined by conventional camera-computer methods as well as by invasive techniques. These have begun to be used in a preliminary manner in a variety of clinical problems associated with left ventricular dysfunction. This review discusses the types of probe systems available, the methods used in positioning them, and details the specifics of their data acquisition and processing capacity. The major criticisms of probe methods are that they are nonimaging and that they measure global rather than regional left ventricular function. In spite of these criticisms, probe systems, because of their portability, high sensitivity, and relatively low cost are useful supplements to conventional camera-computer systems for the measurement of parameters of left ventricular performance using radionuclide techniques.

  3. Diagnostic performance of blood culture bottles for vitreous culture compared to conventional microbiological cultures in patients with suspected endophthalmitis.

    PubMed

    Kehrmann, Jan; Chapot, Valerie; Buer, Jan; Rating, Philipp; Bornfeld, Norbert; Steinmann, Joerg

    2018-05-01

    The purpose of this investigation was to evaluate the performance of blood culture bottles in comparison to conventional microbiological culture techniques in detecting causative microorganisms of endophthalmitis and to determine their anti-infective susceptibility profiles. All consecutive cases with clinically suspected endophthalmitis in a university-based ophthalmology department between January 2009 and December 2016 were analysed in this retrospective comparative case series. Samples from 247 patients with suspected endophthalmitis underwent microbiological diagnostic work-up. All three culture methods were performed from 140 vitreous specimens. Vitreous fluid specimens were inoculated in blood culture bottles, aerobic and anaerobic broth solutions, and on solid media. Anti-infective susceptibility profiles were evaluated by semi-automated methods and/or gradient diffusion methods. Microorganisms were grown in 82 of 140 specimens for which all methods were performed (59%). Microorganisms were more frequently grown from blood culture bottles (55%) compared to broth solution (45%, p = 0.007) and solid media (33%, p < 0.0001). Considerable differences in the performance among culture media were detected for fungal pathogens. All grown fungi were detected by blood culture bottles (11 of 11, 100%). Broth solution recovered 64% and solid media 46% of grown fungi. No Gram-positive bacterium was resistant to vancomycin and all Gram-negative pathogens except for one isolate were susceptible to third-generation cephalosporins. In suspected endophthalmitis patients, blood culture bottles have a higher overall pathogen detection rate from vitreous fluid compared to conventional microbiological media, especially for fungi. The initial intravitreal antibiotic therapy with vancomycin plus third-generation cephalosporins appears to be an appropriate treatment approach for bacterial endophthalmitis.

  4. The challenges and promises of genetic approaches for ballast water management

    NASA Astrophysics Data System (ADS)

    Rey, Anaïs; Basurko, Oihane C.; Rodríguez-Ezpeleta, Naiara

    2018-03-01

    Ballast water is a main vector of introduction of Harmful Aquatic Organisms and Pathogens, which includes Non-Indigenous Species. Numerous and diversified organisms are transferred daily from a donor to a recipient port. Developed to prevent these introduction events, the International Convention for the Control and Management of Ships' Ballast Water and Sediments will enter into force in 2017. This international convention is asking for the monitoring of Harmful Aquatic Organisms and Pathogens. In this review, we highlight the urgent need to develop cost-effective methods to: (1) perform the biological analyses required by the convention; and (2) assess the effectiveness of two main ballast water management strategies, i.e. the ballast water exchange and the use of ballast water treatment systems. We have compiled the biological analyses required by the convention, and performed a comprehensive evaluation of the potential and challenges of the use of genetic tools in this context. Following an overview of the studies applying genetic tools to ballast water related research, we present metabarcoding as a relevant approach for early detection of Harmful Aquatic Organisms and Pathogens in general and for ballast water monitoring and port risk assessment in particular. Nonetheless, before implementation of genetic tools in the context of the ballast water management convention, benchmarked tests against traditional methods should be performed, and standard, reproducible and easy to apply protocols should be developed.

  5. ASPECTS: an automation-assisted SPE method development system.

    PubMed

    Li, Ming; Chou, Judy; King, Kristopher W; Yang, Liyu

    2013-07-01

    A typical conventional SPE method development (MD) process usually involves deciding the chemistry of the sorbent and eluent based on information about the analyte; experimentally preparing and trying out various combinations of adsorption chemistry and elution conditions; quantitatively evaluating the various conditions; and comparing quantitative results from all combination of conditions to select the best condition for method qualification. The second and fourth steps have mostly been performed manually until now. We developed an automation-assisted system that expedites the conventional SPE MD process by automating 99% of the second step, and expedites the fourth step by automatically processing the results data and presenting it to the analyst in a user-friendly format. The automation-assisted SPE MD system greatly saves the manual labor in SPE MD work, prevents analyst errors from causing misinterpretation of quantitative results, and shortens data analysis and interpretation time.

  6. CNN based approach for activity recognition using a wrist-worn accelerometer.

    PubMed

    Panwar, Madhuri; Dyuthi, S Ram; Chandra Prakash, K; Biswas, Dwaipayan; Acharyya, Amit; Maharatna, Koushik; Gautam, Arvind; Naik, Ganesh R

    2017-07-01

    In recent years, significant advancements have taken place in human activity recognition using various machine learning approaches. However, feature engineering have dominated conventional methods involving the difficult process of optimal feature selection. This problem has been mitigated by using a novel methodology based on deep learning framework which automatically extracts the useful features and reduces the computational cost. As a proof of concept, we have attempted to design a generalized model for recognition of three fundamental movements of the human forearm performed in daily life where data is collected from four different subjects using a single wrist worn accelerometer sensor. The validation of the proposed model is done with different pre-processing and noisy data condition which is evaluated using three possible methods. The results show that our proposed methodology achieves an average recognition rate of 99.8% as opposed to conventional methods based on K-means clustering, linear discriminant analysis and support vector machine.

  7. Denoising time-domain induced polarisation data using wavelet techniques

    NASA Astrophysics Data System (ADS)

    Deo, Ravin N.; Cull, James P.

    2016-05-01

    Time-domain induced polarisation (TDIP) methods are routinely used for near-surface evaluations in quasi-urban environments harbouring networks of buried civil infrastructure. A conventional technique for improving signal to noise ratio in such environments is by using analogue or digital low-pass filtering followed by stacking and rectification. However, this induces large distortions in the processed data. In this study, we have conducted the first application of wavelet based denoising techniques for processing raw TDIP data. Our investigation included laboratory and field measurements to better understand the advantages and limitations of this technique. It was found that distortions arising from conventional filtering can be significantly avoided with the use of wavelet based denoising techniques. With recent advances in full-waveform acquisition and analysis, incorporation of wavelet denoising techniques can further enhance surveying capabilities. In this work, we present the rationale for utilising wavelet denoising methods and discuss some important implications, which can positively influence TDIP methods.

  8. Assessing nest-building behavior of mice using a 3D depth camera.

    PubMed

    Okayama, Tsuyoshi; Goto, Tatsuhiko; Toyoda, Atsushi

    2015-08-15

    We developed a novel method to evaluate the nest-building behavior of mice using an inexpensive depth camera. The depth camera clearly captured nest-building behavior. Using three-dimensional information from the depth camera, we obtained objective features for assessing nest-building behavior, including "volume," "radius," and "mean height". The "volume" represents the change in volume of the nesting material, a pressed cotton square that a mouse shreds and untangles in order to build its nest. During the nest-building process, the total volume of cotton fragments is increased. The "radius" refers to the radius of the circle enclosing the fragments of cotton. It describes the extent of nesting material dispersion. The "radius" averaged approximately 60mm when a nest was built. The "mean height" represents the change in the mean height of objects. If the nest walls were high, the "mean height" was also high. These features provided us with useful information for assessment of nest-building behavior, similar to conventional methods for the assessment of nest building. However, using the novel method, we found that JF1 mice built nests with higher walls than B6 mice, and B6 mice built nests faster than JF1 mice. Thus, our novel method can evaluate the differences in nest-building behavior that cannot be detected or quantified by conventional methods. In future studies, we will evaluate nest-building behaviors of genetically modified, as well as several inbred, strains of mice, with several nesting materials. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Evaluation of magnetic nanoparticle samples made from biocompatible ferucarbotran by time-correlation magnetic particle imaging reconstruction method

    PubMed Central

    2013-01-01

    Background Molecular imaging using magnetic nanoparticles (MNPs)—magnetic particle imaging (MPI)—has attracted interest for the early diagnosis of cancer and cardiovascular disease. However, because a steep local magnetic field distribution is required to obtain a defined image, sophisticated hardware is required. Therefore, it is desirable to realize excellent image quality even with low-performance hardware. In this study, the spatial resolution of MPI was evaluated using an image reconstruction method based on the correlation information of the magnetization signal in a time domain and by applying MNP samples made from biocompatible ferucarbotran that have adjusted particle diameters. Methods The magnetization characteristics and particle diameters of four types of MNP samples made from ferucarbotran were evaluated. A numerical analysis based on our proposed method that calculates the image intensity from correlation information between the magnetization signal generated from MNPs and the system function was attempted, and the obtained image quality was compared with that using the prototype in terms of image resolution and image artifacts. Results MNP samples obtained by adjusting ferucarbotran showed superior properties to conventional ferucarbotran samples, and numerical analysis showed that the same image quality could be obtained using a gradient magnetic field generator with 0.6 times the performance. However, because image blurring was included theoretically by the proposed method, an algorithm will be required to improve performance. Conclusions MNP samples obtained by adjusting ferucarbotran showed magnetizing properties superior to conventional ferucarbotran samples, and by using such samples, comparable image quality (spatial resolution) could be obtained with a lower gradient magnetic field intensity. PMID:23734917

  10. Comparison of the Debonding Characteristics of Conventional and New Debonding Instrument used for Ceramic, Composite and Metallic Brackets - An Invitro Study.

    PubMed

    Choudhary, Garima; Gill, Vikas; Reddy, Y N N; Sanadhya, Sudhanshu; Aapaliya, Pankaj; Sharma, Nidhi

    2014-07-01

    Debonding procedure is time consuming and damaging to the enamel if performed with improper technique. Various debonding methods include: the conventional methods that use pliers or wrenches, an ultrasonic method, electrothermal devices, air pressure impulse devices, diamond burs to grind the brackets off the tooth surface and lasers. Among all these methods, using debonding pliers is most convenient and effective method but has been reported to cause damage to the teeth. Recently, a New Debonding Instrument designed specifically for ceramic and composite brackets has been introduced. As this is a new instrument, little information is available on efficacy of this instrument. The purpose of this study was to evaluate the debonding characteristics of both "the conventional debonding Pliers" and "the New debonding instrument" when removing ceramic, composite and metallic brackets. One Hundred Thirty eight extracted maxillary premolar teeth were collected and divided into two Groups: Group A and Group B (n = 69) respectively. They were further divided into 3 subGroups (n = 23) each according to the types of brackets to be bonded. In subGroups A1 and B1{stainless steel};A2 and B2{ceramic};A3 and B3{composite}adhesive precoated maxillary premolar brackets were used. Among them {ceramic and composite} adhesive pre-coated maxillary premolar brackets were bonded. All the teeth were etched using 37% phosphoric acid for 15 seconds and the brackets were bonded using Transbond XT primer. Brackets were debonded using Conventional Debonding Plier and New Debonding Instrument (Group B). After debonding, the enamel surface of each tooth was examined under stereo microscope (10X magnifications). Amodifiedadhesive remnant index (ARI) was used to quantify the amount of remaining adhesive on each tooth. The observations demonstrate that the results of New Debonding Instrument for debonding of metal, ceramic and composite brackets were statistically significantly different (p = 0.04) and superior from the results of conventional debonding Pliers. The debonding efficiency of New Debonding Instrument is better than the debonding efficiency of Conventional Debonding Pliers for use of metal, ceramic and composite brackets respectively.

  11. Development and comparison of a real-time PCR assay for detection of Dichelobacter nodosus with culturing and conventional PCR: harmonisation between three laboratories

    PubMed Central

    2012-01-01

    Background Ovine footrot is a contagious disease with worldwide occurrence in sheep. The main causative agent is the fastidious bacterium Dichelobacter nodosus. In Scandinavia, footrot was first diagnosed in Sweden in 2004 and later also in Norway and Denmark. Clinical examination of sheep feet is fundamental to diagnosis of footrot, but D. nodosus should also be detected to confirm the diagnosis. PCR-based detection using conventional PCR has been used at our institutes, but the method was laborious and there was a need for a faster, easier-to-interpret method. The aim of this study was to develop a TaqMan-based real-time PCR assay for detection of D. nodosus and to compare its performance with culturing and conventional PCR. Methods A D. nodosus-specific TaqMan based real-time PCR assay targeting the 16S rRNA gene was designed. The inclusivity and exclusivity (specificity) of the assay was tested using 55 bacterial and two fungal strains. To evaluate the sensitivity and harmonisation of results between different laboratories, aliquots of a single DNA preparation were analysed at three Scandinavian laboratories. The developed real-time PCR assay was compared to culturing by analysing 126 samples, and to a conventional PCR method by analysing 224 samples. A selection of PCR-products was cloned and sequenced in order to verify that they had been identified correctly. Results The developed assay had a detection limit of 3.9 fg of D. nodosus genomic DNA. This result was obtained at all three laboratories and corresponds to approximately three copies of the D. nodosus genome per reaction. The assay showed 100% inclusivity and 100% exclusivity for the strains tested. The real-time PCR assay found 54.8% more positive samples than by culturing and 8% more than conventional PCR. Conclusions The developed real-time PCR assay has good specificity and sensitivity for detection of D. nodosus, and the results are easy to interpret. The method is less time-consuming than either culturing or conventional PCR. PMID:22293440

  12. A randomized control trial evaluating fluorescent ink versus dark ink tattoos for breast radiotherapy

    PubMed Central

    Kirby, Anna M; Lee, Steven F; Bartlett, Freddie; Titmarsh, Kumud; Donovan, Ellen; Griffin, Clare L; Gothard, Lone; Locke, Imogen; McNair, Helen A

    2016-01-01

    Objective: The purpose of this UK study was to evaluate interfraction reproducibility and body image score when using ultraviolet (UV) tattoos (not visible in ambient lighting) for external references during breast/chest wall radiotherapy and compare with conventional dark ink. Methods: In this non-blinded, single-centre, parallel group, randomized control trial, patients were allocated to receive either conventional dark ink or UV ink tattoos using computer-generated random blocks. Participant assignment was not masked. Systematic (∑) and random (σ) setup errors were determined using electronic portal images. Body image questionnaires were completed at pre-treatment, 1 month and 6 months to determine the impact of tattoo type on body image. The primary end point was to determine that UV tattoo random error (σsetup) was no less accurate than with conventional dark ink tattoos, i.e. <2.8 mm. Results: 46 patients were randomized to receive conventional dark or UV ink tattoos. 45 patients completed treatment (UV: n = 23, dark: n = 22). σsetup for the UV tattoo group was <2.8 mm in the u and v directions (p = 0.001 and p = 0.009, respectively). A larger proportion of patients reported improvement in body image score in the UV tattoo group compared with the dark ink group at 1 month [56% (13/23) vs 14% (3/22), respectively] and 6 months [52% (11/21) vs 38% (8/21), respectively]. Conclusion: UV tattoos were associated with interfraction setup reproducibility comparable with conventional dark ink. Patients reported a more favourable change in body image score up to 6 months following treatment. Advances in knowledge: This study is the first to evaluate UV tattoo external references in a randomized control trial. PMID:27710100

  13. Woodstove Emission Sampling Methods Comparability Analysis and In-situ Evaluation of New Technology Woodstoves.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simons, Carl A.

    1988-06-01

    One major objective of this study was to compare several woodstove particulate emission sampling methods under laboratory and in-situ conditions. The laboratory work compared the EPA Method 5H, EPA Method 5G, and OMNI Automated Woodstove Emission Sampler (AWES)/Data LOG'r particulate emission sampling systems. A second major objective of the study was to evaluate the performance of two integral catalytic, two low emission non-catalytic, and two conventional technology woodstoves under in-situ conditions with AWES/Data LOG'r system. The AWES/Data LOG'r and EPA Method 5G sampling systems were also compared in an in-situ test on one of the integral catalytic woodstove models. 7more » figs., 12 tabs.« less

  14. Pain Elimination during Injection with Newer Electronic Devices: A Comparative Evaluation in Children.

    PubMed

    Bansal, Neha; Saha, Sonali; Jaiswal, Jn; Samadi, Firoza

    2014-05-01

    The present study was taken up to clinically evaluate and compare effectiveness of transcutaneous electrical nerve stimulator (TENS) and comfort control syringe (CCS) in various pediatric dental procedures as an alternative to the conventional method of local anesthesia (LA) administration. Ninety healthy children having at least one deciduous molar tooth indicated for extraction in either maxillary right or left quadrant in age group of 6 to 10 years were randomly divided into three equal groups having 30 subjects each. Group I: LA administration using conventional syringe, group II: LA administration using TENS along with the conventional syringe, group III: LA administration using CCS. After LA by the three techniques, pain, anxiety and heart rate were measured. The observations, thus, obtained were subjected to statistical analysis using analysis of variance (ANOVA), student t-test and paired t-test. The mean pain score was maximum in group I followed by group II, while group III revealed the minimum pain, where LA was administered using CCS. Mean anxiety score was maximum in group I followed by group II, while group III revealed the minimum score. Mean heart rate was maximum in group I followed in descending order by groups II and III. The study supports the belief that CCS could be a viable alternative in comparison to the other two methods of LA delivery in children. How to cite this article: Bansal N, Saha S, Jaiswal JN, Samadi F. Pain Elimination during Injection with Newer Electronic Devices: A Comparative Evaluation in Children. Int J Clin Pediatr Dent 2014;7(2):71-76.

  15. Evaluation of marginal and internal gaps of metal ceramic crowns obtained from conventional impressions and casting techniques with those obtained from digital techniques.

    PubMed

    Rai, Rathika; Kumar, S Arun; Prabhu, R; Govindan, Ranjani Thillai; Tanveer, Faiz Mohamed

    2017-01-01

    Accuracy in fit of cast metal restoration has always remained as one of the primary factors in determining the success of the restoration. A well-fitting restoration needs to be accurate both along its margin and with regard to its internal surface. The aim of the study is to evaluate the marginal fit of metal ceramic crowns obtained by conventional inlay casting wax pattern using conventional impression with the metal ceramic crowns obtained by computer-aided design and computer-aided manufacturing (CAD/CAM) technique using direct and indirect optical scanning. This in vitro study on preformed custom-made stainless steel models with former assembly that resembles prepared tooth surfaces of standardized dimensions comprised three groups: the first group included ten samples of metal ceramic crowns fabricated with conventional technique, the second group included CAD/CAM-milled direct metal laser sintering (DMLS) crowns using indirect scanning, and the third group included DMLS crowns fabricated by direct scanning of the stainless steel model. The vertical marginal gap and the internal gap were evaluated with the stereomicroscope (Zoomstar 4); post hoc Turkey's test was used for statistical analysis. One-way analysis of variance method was used to compare the mean values. Metal ceramic crowns obtained from direct optical scanning showed the least marginal and internal gap when compared to the castings obtained from inlay casting wax and indirect optical scanning. Indirect and direct optical scanning had yielded results within clinically acceptable range.

  16. Development Of Methodologies Using PhabrOmeter For Fabric Drape Evaluation

    NASA Astrophysics Data System (ADS)

    Lin, Chengwei

    Evaluation of fabric drape is important for textile industry as it reveals the aesthetic and functionality of the cloth and apparel. Although many fabric drape measuring methods have been developed for several decades, they are falling behind the need for fast product development by the industry. To meet the requirement of industries, it is necessary to develop an effective and reliable method to evaluate fabric drape. The purpose of the present study is to determine if PhabrOmeter can be applied to fabric drape evaluation. PhabrOmeter is a fabric sensory performance evaluating instrument which is developed to provide fast and reliable quality testing results. This study was sought to determine the relationship between fabric drape and other fabric attributes. In addition, a series of conventional methods including AATCC standards, ASTM standards and ISO standards were used to characterize the fabric samples. All the data were compared and analyzed with linear correlation method. The results indicate that PhabrOmeter is reliable and effective instrument for fabric drape evaluation. Besides, some effects including fabric structure, testing directions were considered to examine their impact on fabric drape.

  17. Transparency-enhancing technology allows three-dimensional assessment of gastrointestinal mucosa: A porcine model.

    PubMed

    Mizutani, Hiroya; Ono, Satoshi; Ushiku, Tetsuo; Kudo, Yotaro; Ikemura, Masako; Kageyama, Natsuko; Yamamichi, Nobutake; Fujishiro, Mitsuhiro; Someya, Takao; Fukayama, Masashi; Koike, Kazuhiko; Onodera, Hiroshi

    2018-02-01

    Although high-resolution three-dimensional imaging of endoscopically resected gastrointestinal specimens can help elucidating morphological features of gastrointestinal mucosa or tumor, there are no established methods to achieve this without breaking specimens apart. We evaluated the utility of transparency-enhancing technology for three-dimensional assessment of gastrointestinal mucosa in porcine models. Esophagus, stomach, and colon mucosa samples obtained from a sacrificed swine were formalin-fixed and paraffin-embedded, and subsequently deparaffinized for analysis. The samples were fluorescently stained, optically cleared using transparency-enhancing technology: ilLUmination of Cleared organs to IDentify target molecules method (LUCID), and visualized using laser scanning microscopy. After observation, all specimens were paraffin-embedded again and evaluated by conventional histopathological assessment to measure the impact of transparency-enhancing procedures. As a result, microscopic observation revealed horizontal section views of mucosa at deeper levels and enabled the three-dimensional image reconstruction of glandular and vascular structures. Besides, paraffin-embedded specimens after transparency-enhancing procedures were all assessed appropriately by conventional histopathological staining. These results suggest that transparency-enhancing technology may be feasible for clinical application and enable the three-dimensional structural analysis of endoscopic resected specimen non-destructively. Although there remain many limitations or problems to be solved, this promising technology might represent a novel histopathological method for evaluating gastrointestinal cancers. © 2018 Japanese Society of Pathology and John Wiley & Sons Australia, Ltd.

  18. The use of light-emitting diode fluorescence to diagnose mycobacterial lymphadenitis in fine-needle aspirates from children

    PubMed Central

    van Wyk, A. C.; Marais, B. J.; Warren, R. M.; van Wyk, S. S.; Wright, C. A.

    2011-01-01

    SUMMARY BACKGROUND Fine-needle aspiration biopsy (FNAB) is a simple, safe and effective method for investigating suspected mycobacterial lymphadenitis in children. Fluorescence microscopy can provide rapid mycobacterial confirmation. Light-emitting diodes (LEDs) provide a cheap and robust excitation light source, making fluorescence microscopy feasible in resource-limited settings. OBJECTIVE To compare the diagnostic performance of LED fluorescence microscopy on Papanicolaou (PAP) stained smears with the conventional mercury vapour lamp (MVL). METHODS FNAB smears routinely collected from palpable lymph nodes in children with suspected mycobacterial disease were PAP-stained and evaluated by two independent microscopists using different excitatory light sources (MVL and LED). Mycobacterial culture results provided the reference standard. A manually rechargeable battery-powered LED power source was evaluated in a random subset. RESULTS We evaluated 182 FNAB smears from 121 children (median age 31 months, interquartile range 10–67). Mycobacterial cultures were positive in 84 of 121 (69%) children. The mean sensitivity with LED (mains-powered), LED (rechargeable battery-powered) and MVL was respectively 48.2%, 50.0% and 51.8% (specificity 78.4%, 86.7% and 78.4%). Inter-observer variation was similar for LED and MVL (κ = 0.5). CONCLUSION LED fluorescence microscopy provides a reliable alternative to conventional methods and has many favourable attributes that would facilitate improved, decentralised diagnostic services. PMID:21276297

  19. Evaluation of nutrient agar for the culture of Mycobacterium tuberculosis using the microcolony detection method.

    PubMed

    Satti, L; Abbasi, S; Faiz, U

    2012-07-01

    We evaluated nutrient agar using the microcolony detection method for the recovery of Mycobacterium tuberculosis on 37 acid-fast bacilli (AFB) positive sputum specimens, and compared it with conventional Löwenstein-Jensen (LJ) medium. Nutrient agar detected 35 isolates compared to 34 on LJ medium. The mean time to detection of mycobacteria on nutrient agar and LJ medium was respectively 9.6 and 21.4 days. The contamination rate on nutrient agar and LJ medium was respectively 5.4% and 2.7%. Nutrient agar detects M. tuberculosis more rapidly than LJ medium, and could be an economical, rapid culture method in resource-poor settings, provided our findings are confirmed by further studies.

  20. Applications guide for waste heat recovery

    NASA Technical Reports Server (NTRS)

    Moynihan, P. I.

    1983-01-01

    The state-of-the-art of commercially available organic Rankine cycle (ORC) hardware from a literature search and industry survey is assessed. Engineering criteria for applying ORC technology are established, and a set of nomograms to enable the rapid sizing of the equipment is presented. A comparison of an ORC system with conventional heat recovery techniques can be made with a nomogram developed for a recuperative heat exchanger. A graphical technique for evaluating the economic aspects of an ORC system and conventional heat recovery method is discussed: also included is a description of anticipated future trends in organic Rankine cycle R&D.

  1. Comparison of Kato-Katz, ethyl-acetate sedimentation, and Midi Parasep® in the diagnosis of hookworm, Ascaris and Trichuris infections in the context of an evaluation of rural sanitation in India.

    PubMed

    Funk, Anna L; Boisson, Sophie; Clasen, Thomas; Ensink, Jeroen H J

    2013-06-01

    The Kato-Katz, conventional ethyl-acetate sedimentation, and Midi Parasep(®) methods for diagnosing infection with soil-transmitted helminths were compared. The Kato-Katz technique gave the best overall diagnostic performance with the highest results in all measures (prevalence, faecal egg count, sensitivity) followed by the conventional ethyl-acetate and then the Midi Parasep(®) technique. The Kato-Katz technique showed a significantly higher faecal egg count and sensitivity for both hookworm and Trichuris as compared to the Midi Parasep(®) technique. The conventional ethyl-acetate technique produced smaller pellets and showed lower pellet mobility as compared to the Midi Parasep(®). Copyright © 2013 Elsevier B.V. All rights reserved.

  2. A field evaluation of the Hardy TB MODS Kit™ for the rapid phenotypic diagnosis of tuberculosis and multi-drug resistant tuberculosis.

    PubMed

    Martin, Laura; Coronel, Jorge; Faulx, Dunia; Valdez, Melissa; Metzler, Mutsumi; Crudder, Chris; Castillo, Edith; Caviedes, Luz; Grandjean, Louis; Rodriguez, Mitzi; Friedland, Jon S; Gilman, Robert H; Moore, David A J

    2014-01-01

    Even though the WHO-endorsed, non-commercial MODS assay offers rapid, reliable TB liquid culture and phenotypic drug susceptibility testing (DST) at lower cost than any other diagnostic, uptake has been patchy. In part this reflects misperceptions about in-house assay quality assurance, but user convenience of one-stop procurement is also important. A commercial MODS kit was developed by Hardy Diagnostics (Santa Maria, CA, USA) with PATH (Seattle, WA, USA) to facilitate procurement, simplify procedures through readymade media, and enhance safety with a sealing silicone plate lid. Here we report the results from a large-scale field evaluation of the MODS kit in a government service laboratory. 2446 sputum samples were cultured in parallel in Lowenstein-Jensen (LJ), conventional MODS and in the MODS kit. MODS kit DST was compared with conventional MODS (direct) DST and proportion method (indirect) DST. 778 samples (31.8%) were Mycobacterium tuberculosis culture-positive. Compared to conventional MODS the sensitivity, specificity, positive, and negative predictive values (95% confidence intervals) of the MODS Kit were 99.3% (98.3-99.8%), 98.3% (97.5-98.8%), 95.8% (94.0-97.1%), and 99.7% (99.3-99.9%). Median (interquartile ranges) time to culture-positivity (and rifampicin and isoniazid DST) was 10 (9-13) days for conventional MODS and 8.5 (7-11) for MODS Kit (p<0.01). Direct rifampicin and isoniazid DST in MODS kit was almost universally concordant with conventional MODS (97.9% agreement, 665/679 evaluable samples) and reference indirect DST (97.9% agreement, 687/702 evaluable samples). MODS kit delivers performance indistinguishable from conventional MODS and offers a convenient, affordable alternative with enhanced safety from the sealing silicone lid. The availability in the marketplace of this platform, which conforms to European standards (CE-marked), readily repurposed for second-line DST in the near future, provides a fresh opportunity for improving equity of access to TB diagnosis and first and second-line DST in settings where the need is greatest.

  3. Development of Al2O3 electrospun fibers prepared by conventional sintering method or plasma assisted surface calcination

    NASA Astrophysics Data System (ADS)

    Mudra, E.; Streckova, M.; Pavlinak, D.; Medvecka, V.; Kovacik, D.; Kovalcikova, A.; Zubko, P.; Girman, V.; Dankova, Z.; Koval, V.; Duzsa, J.

    2017-09-01

    In this paper, the electrospinning method was used for preparation of α-Al2O3 microfibers from PAN/Al(NO3)3 precursor solution. The precursor fibers were thermally treated by conventional method in furnace or low-temperature plasma induced surface sintering method in ambient air. The four different temperatures of PAN/Al(NO3)3 precursors were chosen for formation of α-Al2O3 phase by conventional sintering way according to the transition features observed in the TG/DSC analysis. In comparison, the low-temperature plasma treatment at atmospheric pressure was used as an alternative sintering method at the exposure times of 5, 10 and 30 min. FTIR analysis was used for evaluation of residual polymer after plasma induced calcination and for studying the mechanism of polymer degradation. The polycrystalline alumina fibers arranged with the nanoparticles was created continuously throughout the whole volume of the sample. On the other side the low temperature approach, high density of reactive species and high power density of plasma generated at atmospheric pressure by used plasma source allowed rapid removal of polymer in preference from the surface of fibers leading to the formation of composite ceramic/polymer fibers. This plasma induced sintering of PAN/Al(NO3)3 can have obvious importance in industrial applications where the ceramic character of surface with higher toughness of the fibers are required.

  4. Development and Evaluation of a Combined Cultivator and Band Sprayer with a Row-Centering RTK-GPS Guidance System

    PubMed Central

    Perez-Ruiz, Manuel; Carballido, Jacob; Agüera, Juan; Rodríguez-Lizana, Antonio

    2013-01-01

    Typically, low-pressure sprayers are used to uniformly apply pre- and post-emergent herbicides to control weeds in crop rows. An innovative machine for weed control in inter-row and intra-row areas, with a unique combination of inter-row cultivation tooling and intra-row band spraying for six rows and an electro-hydraulic side-shift frame controlled by a GPS system, was developed and evaluated. Two weed management strategies were tested in the field trials: broadcast spraying (the conventional method) and band spraying with mechanical weed control using RTK-GPS (the experimental method). This approach enabled the comparison between treatments from the perspective of cost savings and efficacy in weed control for a sugar beet crop. During the 2010–2011 season, the herbicide application rate (112 L ha−1) of the experimental method was approximately 50% of the conventional method, and thus a significant reduction in the operating costs of weed management was achieved. A comparison of the 0.2-trimmed means of weed population post-treatment showed that the treatments achieved similar weed control rates at each weed survey date. Sugar beet yields were similar with both methods (p = 0.92). The use of the experimental equipment is cost-effective on ≥20 ha of crops. These initial results show good potential for reducing herbicide application in the Spanish beet industry. PMID:23478600

  5. Development and evaluation of a combined cultivator and band sprayer with a row-centering RTK-GPS guidance system.

    PubMed

    Perez-Ruiz, Manuel; Carballido, Jacob; Agüera, Juan; Rodríguez-Lizana, Antonio

    2013-03-11

    Typically, low-pressure sprayers are used to uniformly apply pre- and post-emergent herbicides to control weeds in crop rows. An innovative machine for weed control in inter-row and intra-row areas, with a unique combination of inter-row cultivation tooling and intra-row band spraying for six rows and an electro-hydraulic side-shift frame controlled by a GPS system, was developed and evaluated. Two weed management strategies were tested in the field trials: broadcast spraying (the conventional method) and band spraying with mechanical weed control using RTK-GPS (the experimental method). This approach enabled the comparison between treatments from the perspective of cost savings and efficacy in weed control for a sugar beet crop. During the 2010-2011 season, the herbicide application rate (112 L ha(-1)) of the experimental method was approximately 50% of the conventional method, and thus a significant reduction in the operating costs of weed management was achieved. A comparison of the 0.2-trimmed means of weed population post-treatment showed that the treatments achieved similar weed control rates at each weed survey date. Sugar beet yields were similar with both methods (p = 0.92). The use of the experimental equipment is cost-effective on ≥20 ha of crops. These initial results show good potential for reducing herbicide application in the Spanish beet industry.

  6. Development of a panel of seven duplex real-time PCR assays for detecting 13 streptococcal superantigens.

    PubMed

    Yang, Peng; Peng, Xiaomin; Cui, Shujuan; Shao, Junbin; Zhu, Xuping; Zhang, Daitao; Liang, Huijie; Wang, Quanyi

    2013-07-30

    Streptococcal superantigens (SAgs) are the major virulence factors of infection in humans for group A Streptococcus (GAS) bacteria. A panel consisting of seven duplex real-time PCR assays was developed to simultaneously detect 13 streptococcal SAgs and one internal control which may be important in the control of GAS-mediated diseases. Primer and probe sequences were selected based on the highly conserved region from an alignment of nucleotide sequences of the 13 streptococcal SAgs. The reaction conditions of the duplex real-time PCR were optimized and the specificity of the duplex assays was evaluated using SAg positive strains. The limit of detection of the duplex assays was determined by using 10-fold serial dilutions of the DNA of 13 streptococcal SAgs and compared to a conventional polymerase chain reaction (PCR) method for evaluating the duplex assays sensitivity. Using the duplex assays, we were able to differentiate between 13 SAgs from Streptococcus strains and other non-Streptococcus bacteria without cross-reaction. On the other hand, the limit of detection of the duplex assays was at least one or two log dilutions lower than that of the conventional PCR. The panel was highly specific (100%) and the limit of detection of these duplex groups was at least ten times lower than that obtained by using a conventional PCR method.

  7. Characterization of benign thyroid nodules with HyperSPACE (Hyper Spectral Analysis for Characterization in Echography) before and after percutaneous laser ablation: a pilot study.

    PubMed

    Granchi, Simona; Vannacci, Enrico; Biagi, Elena

    2017-04-22

    To evaluate the capability of the HyperSPACE (Hyper SPectral Analysis for Characterization in Echography) method in tissue characterization, in order to provide information for the laser treatment of benign thyroid nodules in respect of conventional B-mode images and elastography. The method, based on the spectral analysis of the raw radiofrequency ultrasonic signal, was applied to characterize the nodule before and after laser treatment. Thirty patients (25 females and 5 males, age between 37 and 81 years) with thyroid benign nodule at cytology (Thyr 2) were evaluated by conventional ultrasonography, elastography, and HyperSPACE, before and after laser ablation. The images processed by HyperSPACE exhibit different color distributions that are referred to different tissue features. By calculating the percentages of the color coverages, the analysed nodules were subdivided into 3 groups. Each nodule belonging to the same group experienced, on average, similar necrosis extension. The nodules exhibit different Configurations (colors) distributions that could be indicative of the response of nodular tissue to the laser treatmentConclusions: HyperSPACEcan characterize benign nodules by providing additional information in respect of conventional ultrasound and elastography which is useful for support in the laser treatment of nodules in order to increase the probability of success.

  8. Comparative study of torque expression among active and passive self-ligating and conventional brackets

    PubMed Central

    Franco, Érika Mendonça Fernandes; Valarelli, Fabrício Pinelli; Fernandes, João Batista; Cançado, Rodrigo Hermont; de Freitas, Karina Maria Salvatore

    2015-01-01

    Abstract Objective: The aim of this study was to compare torque expression in active and passive self-ligating and conventional brackets. Methods: A total of 300 segments of stainless steel wire 0.019 x 0.025-in and six different brands of brackets (Damon 3MX, Portia, In-Ovation R, Bioquick, Roth SLI and Roth Max) were used. Torque moments were measured at 12°, 24°, 36° and 48°, using a wire torsion device associated with a universal testing machine. The data obtained were compared by analysis of variance followed by Tukey test for multiple comparisons. Regression analysis was performed by the least-squares method to generate the mathematical equation of the optimal curve for each brand of bracket. Results: Statistically significant differences were observed in the expression of torque among all evaluated bracket brands in all evaluated torsions (p < 0.05). It was found that Bioquick presented the lowest torque expression in all tested torsions; in contrast, Damon 3MX bracket presented the highest torque expression up to 36° torsion. Conclusions: The connection system between wire/bracket (active, passive self-ligating or conventional with elastic ligature) seems not to interfere in the final torque expression, the latter being probably dependent on the interaction between the wire and the bracket chosen for orthodontic mechanics. PMID:26691972

  9. Rapid identification of clinical mycobacterial isolates by protein profiling using matrix assisted laser desorption ionization-time of flight mass spectrometry.

    PubMed

    Panda, A; Kurapati, S; Samantaray, J C; Myneedu, V P; Verma, A; Srinivasan, A; Ahmad, H; Behera, D; Singh, U B

    2013-01-01

    The purpose of this study was to evaluate the identification of Mycobacterium tuberculosis which is often plagued with ambiguity. It is a time consuming process requiring 4-8 weeks after culture positivity, thereby delaying therapeutic intervention. For a successful treatment and disease management, timely diagnosis is imperative. We evaluated a rapid, proteomic based technique for identification of clinical mycobacterial isolates by protein profiling using matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). Freshly grown mycobacterial isolates were used. Acetonitrile/trifluoroacetic acid extraction procedure was carried out, following which cinnamic acid charged plates were subjected to identification by MALDI-TOF MS. A comparative analysis of 42 clinical mycobacterial isolates using the MALDI-TOF MS and conventional techniques was carried out. Among these, 97.61% were found to corroborate with the standard methods at genus level and 85.36% were accurate till the species level. One out of 42 was not in accord with the conventional assays because MALDI-TOF MS established it as Mycobacterium tuberculosis (log (score)>2.0) and conventional methods established it to be non-tuberculous Mycobacterium. MALDI-TOF MS was found to be an accurate, rapid, cost effective and robust system for identification of mycobacterial species. This innovative approach holds promise for early therapeutic intervention leading to better patient care.

  10. Validity and reliability of intraoral scanners compared to conventional gypsum models measurements: a systematic review.

    PubMed

    Aragón, Mônica L C; Pontes, Luana F; Bichara, Lívia M; Flores-Mir, Carlos; Normando, David

    2016-08-01

    The development of 3D technology and the trend of increasing the use of intraoral scanners in dental office routine lead to the need for comparisons with conventional techniques. To determine if intra- and inter-arch measurements from digital dental models acquired by an intraoral scanner are as reliable and valid as the similar measurements achieved from dental models obtained through conventional intraoral impressions. An unrestricted electronic search of seven databases until February 2015. Studies that focused on the accuracy and reliability of images obtained from intraoral scanners compared to images obtained from conventional impressions. After study selection the QUADAS risk of bias assessment tool for diagnostic studies was used to assess the risk of bias (RoB) among the included studies. Four articles were included in the qualitative synthesis. The scanners evaluated were OrthoProof, Lava, iOC intraoral, Lava COS, iTero and D250. These studies evaluated the reliability of tooth widths, Bolton ratio measurements, and image superimposition. Two studies were classified as having low RoB; one had moderate RoB and the remaining one had high RoB. Only one study evaluated the time required to complete clinical procedures and patient's opinion about the procedure. Patients reported feeling more comfortable with the conventional dental impression method. Associated costs were not considered in any of the included study. Inter- and intra-arch measurements from digital models produced from intraoral scans appeared to be reliable and accurate in comparison to those from conventional impressions. This assessment only applies to the intraoral scanners models considered in the finally included studies. Digital models produced by intraoral scan eliminate the need of impressions materials; however, currently, longer time is needed to take the digital images. PROSPERO (CRD42014009702). None. © The Author 2016. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  11. SU-F-J-210: A Preliminary Study On the Dosimetric Impact of Detector Based Spectral Ct On Proton Therapy Treatment Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, C; Lee, S; Wessels, B

    2016-06-15

    Purpose: To compare the difference in Hounsfield unit-relative stopping power and evaluate the dosimetric impact of spectral vs. conventional CT on proton therapy treatment plans. Method: The Philips prototype (IQon), a detector-based, spectral CT system (spectral) was used to scan calibration and Rando phantoms. Data were reconstructed with and without energy decomposition to produce monoenergetic 70 keV, 140 keV, and the Zeff images. Relative stopping power (RSP) in the head and lung regions were evaluated as a function of HU in order to compare spectral and conventional CT. Treatment plans for the Rando phantom were also generated and used tomore » produce DVHs of fictitious target volume and organ-at-risk contoured on the head and lung. Results: Agreement of the Zeff of the tissue-substitute materials determined using spectral CT agrees to within 1 to 5% of the Zeff of the known phantom composition. The discrepancy is primarily attributed to non-uniformity in the phantom. Differences between the HU-RSP curves obtained using spectral and conventional CT were small except for in the lung curve at HU>1000. The large difference in planned doses using Spectral vs. conventional CT occurred in a low-dose brain region (1.7mm between the locations of the 100 cGy lines and 3 mm for 50 cGy lines). Conclusion: Conventionally, a single HU-RSP from CT scanner is used in proton treatment planning. Spectral CT allows site-specific HU-RSP for each patient. Spectral and conventional HU-RSP may result in different distributions as shown here. Additional study is required to evaluate the impact of Spectral CT in proton treatment planning. This study is part of a research agreement between Philips and University Hospitals/Case Medical Center.« less

  12. Helical CT scan with 2D and 3D reconstructions and virtual endoscopy versus conventional endoscopy in the assessment of airway disease in neonates, infants and children.

    PubMed

    Yunus, Mahira

    2012-11-01

    To study the use of helical computed tomography 2-D and 3-D images, and virtual endoscopy in the evaluation of airway disease in neonates, infants and children and its value in lesion detection, characterisation and extension. Conducted at Al-Noor Hospital, Makkah, Saudi Arabia, from January 1 to June 30, 2006, the study comprised of 40 patients with strider, having various causes of airway obstruction. They were examined by helical CT scan with 2-D and 3-D reconstructions and virtual endoscopy. The level and characterisation of lesions were carried out and results were compared with actual endoscopic findings. Conventional endoscopy was chosen as the gold standard, and the evaluation of endoscopy was done in terms of sensitivity and specificity of the procedure. For statistical purposes, SPSS version 10 was used. All CT methods detected airway stenosis or obstruction. Accuracy was 98% (n=40) for virtual endoscopy, 96% (n=48) for 3-D external rendering, 90% (n=45) for multiplanar reconstructions and 86% (n=43) for axial images. Comparing the results of 3-D internal and external volume rendering images with conventional endoscopy for detection and grading of stenosis were closer than with 2-D minimum intensity multiplanar reconstruction and axial CT slices. Even high-grade stenosis could be evaluated with virtual endoscope through which conventional endoscope cannot be passed. A case of 4-year-old patient with tracheomalacia could not be diagnosed by helical CT scan and virtual bronchoscopy which was diagriosed on conventional endoscopy and needed CT scan in inspiration and expiration. Virtual endoscopy [VE] enabled better assessment of stenosis compared to the reading of 3-D external rendering, 2-D multiplanar reconstruction [MPR] or axial slices. It can replace conventional endoscopy in the assessment of airway disease without any additional risk.

  13. Unsedated transnasal small-caliber esophagogastroduodenoscopy in elderly and bedridden patients

    PubMed Central

    Yuki, Mika; Amano, Yuji; Komazawa, Yoshinori; Fukuhara, Hiroyuki; Shizuku, Toshihiro; Yamamoto, Shun; Kinoshita, Yoshikazu

    2009-01-01

    AIM: To evaluate the safety of unsedated transnasal small-caliber esophagogastroduodenoscopy (EGD) for elderly and critically ill bedridden patients. METHODS: One prospective randomized comparative study and one crossover comparative study between transnasal small-caliber EGD and transoral conventional EGD was done (Study 1). For the comparative study, we enrolled 240 elderly patients aged > 65 years old. For the crossover analysis, we enrolled 30 bedridden patients with percutaneous endoscopic gastrostomy (PEG) (Study 2). We evaluated cardiopulmonary effects by measuring arterial oxygen saturation (SpO2) and calculating the rate-pressure product (RPP) (pulse rate × systolic blood pressure/100) at baseline, 2 and 5 min after endoscopic intubation in Study 1. To assess the risk for endoscopy-related aspiration pneumonia during EGD, we also measured blood leukocyte counts and serum C-reactive protein (CRP) levels before and 3 d after EGD in Study 2. RESULTS: In Study 1, we observed significant decreases in SpO2 during conventional transoral EGD, but not during transnasal small-caliber EGD (0.24% vs -0.24% after 2 min, and 0.18% vs -0.29% after 5 min, P = 0.034, P = 0.044). Significant differences of the RPP were not found between conventional transoral and transnasal small-caliber EGD. In Study 2, crossover analysis showed statistically significant increases of the RPP at 2 min after intubation and the end of endoscopy (26.8 and 34.6 vs 3.1 and 15.2, P = 0.044, P = 0.046), and decreases of SpO2 (-0.8% vs -0.1%, P = 0.042) during EGD with transoral conventional in comparison with transnasal small-caliber endoscopy. Thus, for bedridden patients with PEG feeding, who were examined in the supine position, transoral conventional EGD more severely suppressed cardiopulmonary function than transnasal small-caliber EGD. There were also significant increases in the markers of inflammation, blood leukocyte counts and serum CRP values, in bedridden patients after transoral conventional EGD, but not after transnasal small-caliber EGD performed with the patient in the supine position. Leukocyte count increased from 6053 ± 1975/L to 6900 ± 3392/L (P = 0.0008) and CRP values increased from 0.93 ± 0.24 to 2.49 ± 0.91 mg/dL (P = 0.0005) at 3 d after transoral conventional EGD. Aspiration pneumonia, possibly caused by the endoscopic examination, was found subsequently in two of 30 patients after transoral conventional EGD. CONCLUSION: Transnasal small-caliber EGD is a safer method than transoral conventional EGD in critically ill, bedridden patients who are undergoing PEG feeding. PMID:19938199

  14. A smart rotary technique versus conventional pulpectomy for primary teeth: A randomized controlled clinical study.

    PubMed

    Mokhtari, Negar; Shirazi, Alireza-Sarraf; Ebrahimi, Masoumeh

    2017-11-01

    Techniques with adequate accuracy of working length determination along with shorter duration of treatment in pulpectomy procedure seems to be essential in pediatric dentistry. The aim of the present study was to evaluate the accuracy of root canal length measurement with Root ZX II apex locator and rotary system in pulpectomy of primary teeth. In this randomized control clinical trial complete pulpectomy was performed on 80 mandibular primary molars in 80, 4-6-year-old children. The study population was randomly divided into case and control groups. In control group conventional pulpectomy was performed and in the case group working length was determined by electronic apex locator Root ZXII and instrumented with Mtwo rotary files. Statistical evaluation was performed using Mann-Whitney and Chi-Square tests ( P <0.05). There were no significant differences between electronic apex locator Root ZXII and conventional method in accuracy of root canal length determination. However significantly less time was needed for instrumenting with rotary files ( P =0.000). Considering the comparable results in accuracy of root canal length determination and the considerably shorter instrumentation time in Root ZXII apex locator and rotary system, it may be suggested for pulpectomy in primary molar teeth. Key words: Rotary technique, conventional technique, pulpectomy, primary teeth.

  15. Effect of virtual reality versus conventional physiotherapy on upper extremity function in children with obstetric brachial plexus injury

    PubMed Central

    El-Shamy, Shamekh; Alsharif, Rabab

    2017-01-01

    Objectives: The objective was to evaluate the effects of virtual reality versus conventional physiotherapy on upper extremity function in children with obstetric brachial plexus injury. Methods: Forty children with Erb’s palsy were selected for this randomized controlled study. They were assigned randomly to either group A (conventional physiotherapy program) or group B (virtual reality program using Armeo® spring for 45 min three times/week for 12 successive weeks). Mallet system scores for shoulder function and shoulder abduction, and external rotation range of motion (ROM) were obtained; shoulder abductor, and external rotators isometric strength were evaluated pre-and post-treatment using Mallet scoring system, standard universal goniometer, and handheld dynamometer. Results: The results of this study indicate that the children in both groups showed improvement in shoulder functions post-treatment with greater improvements in group B. The abduction muscle strength after treatment was 8.53 and 11.3 Nm for group A and group B, respectively. The external rotation muscle strength after treatment was 5.88 and 7.45 Nm for group A and group B, respectively. Conclusions: The virtual reality program is a significantly more effective than conventional physiotherapy program in improving the upper extremity functions in children with obstetric brachial plexus injury. PMID:29199193

  16. Can electromagnetic fields influence the structure and enzymatic digest of proteins? A critical evaluation of microwave-assisted proteomics protocols

    PubMed Central

    Damm, Markus; Nusshold, Christoph; Cantillo, David; Rechberger, Gerald N.; Gruber, Karl; Sattler, Wolfgang; Kappe, C. Oliver

    2012-01-01

    This study reevaluates the putative advantages of microwave-assisted tryptic digests compared to conventionally heated protocols performed at the same temperature. An initial investigation of enzyme stability in a temperature range of 37–80 °C demonstrated that trypsin activity declines sharply at temperatures above 60 °C, regardless if microwave dielectric heating or conventional heating is employed. Tryptic digests of three proteins of different size (bovine serum albumin, cytochrome c and β-casein) were thus performed at 37 °C and 50 °C using both microwave and conventional heating applying accurate internal fiber-optic probe reaction temperature measurements. The impact of the heating method on protein degradation and peptide fragment generation was analyzed by SDS-PAGE and MALDI-TOF-MS. Time-dependent tryptic digestion of the three proteins and subsequent analysis of the corresponding cleavage products by MALDI-TOF provided virtually identical results for both microwave and conventional heating. In addition, the impact of electromagnetic field strength on the tertiary structure of trypsin and BSA was evaluated by molecular mechanics calculations. These simulations revealed that the applied field in a typical laboratory microwave reactor is 3–4 orders of magnitude too low to induce conformational changes in proteins or enzymes. PMID:22889711

  17. Exploring a potential energy surface by machine learning for characterizing atomic transport

    NASA Astrophysics Data System (ADS)

    Kanamori, Kenta; Toyoura, Kazuaki; Honda, Junya; Hattori, Kazuki; Seko, Atsuto; Karasuyama, Masayuki; Shitara, Kazuki; Shiga, Motoki; Kuwabara, Akihide; Takeuchi, Ichiro

    2018-03-01

    We propose a machine-learning method for evaluating the potential barrier governing atomic transport based on the preferential selection of dominant points for atomic transport. The proposed method generates numerous random samples of the entire potential energy surface (PES) from a probabilistic Gaussian process model of the PES, which enables defining the likelihood of the dominant points. The robustness and efficiency of the method are demonstrated on a dozen model cases for proton diffusion in oxides, in comparison with a conventional nudge elastic band method.

  18. A conversation-based process tracing method for use with naturalistic decisions: an evaluation study.

    PubMed

    Williamson, J; Ranyard, R; Cuthbert, L

    2000-05-01

    This study is an evaluation of a process tracing method developed for naturalistic decisions, in this case a consumer choice task. The method is based on Huber et al.'s (1997) Active Information Search (AIS) technique, but develops it by providing spoken rather than written answers to respondents' questions, and by including think aloud instructions. The technique is used within a conversation-based situation, rather than the respondent thinking aloud 'into an empty space', as is conventionally the case in think aloud techniques. The method results in a concurrent verbal protocol as respondents make their decisions, and a retrospective report in the form of a post-decision summary. The method was found to be virtually non-reactive in relation to think aloud, although the variable of Preliminary Attribute Elicitation showed some evidence of reactivity. This was a methodological evaluation, and as such the data reported are essentially descriptive. Nevertheless, the data obtained indicate that the method is capable of producing information about decision processes which could have theoretical importance in terms of evaluating models of decision-making.

  19. Motion-compensated speckle tracking via particle filtering

    NASA Astrophysics Data System (ADS)

    Liu, Lixin; Yagi, Shin-ichi; Bian, Hongyu

    2015-07-01

    Recently, an improved motion compensation method that uses the sum of absolute differences (SAD) has been applied to frame persistence utilized in conventional ultrasonic imaging because of its high accuracy and relative simplicity in implementation. However, high time consumption is still a significant drawback of this space-domain method. To seek for a more accelerated motion compensation method and verify if it is possible to eliminate conventional traversal correlation, motion-compensated speckle tracking between two temporally adjacent B-mode frames based on particle filtering is discussed. The optimal initial density of particles, the least number of iterations, and the optimal transition radius of the second iteration are analyzed from simulation results for the sake of evaluating the proposed method quantitatively. The speckle tracking results obtained using the optimized parameters indicate that the proposed method is capable of tracking the micromotion of speckle throughout the region of interest (ROI) that is superposed with global motion. The computational cost of the proposed method is reduced by 25% compared with that of the previous algorithm and further improvement is necessary.

  20. Significance of parametric spectral ratio methods in detection and recognition of whispered speech

    NASA Astrophysics Data System (ADS)

    Mathur, Arpit; Reddy, Shankar M.; Hegde, Rajesh M.

    2012-12-01

    In this article the significance of a new parametric spectral ratio method that can be used to detect whispered speech segments within normally phonated speech is described. Adaptation methods based on the maximum likelihood linear regression (MLLR) are then used to realize a mismatched train-test style speech recognition system. This proposed parametric spectral ratio method computes a ratio spectrum of the linear prediction (LP) and the minimum variance distortion-less response (MVDR) methods. The smoothed ratio spectrum is then used to detect whispered segments of speech within neutral speech segments effectively. The proposed LP-MVDR ratio method exhibits robustness at different SNRs as indicated by the whisper diarization experiments conducted on the CHAINS and the cell phone whispered speech corpus. The proposed method also performs reasonably better than the conventional methods for whisper detection. In order to integrate the proposed whisper detection method into a conventional speech recognition engine with minimal changes, adaptation methods based on the MLLR are used herein. The hidden Markov models corresponding to neutral mode speech are adapted to the whispered mode speech data in the whispered regions as detected by the proposed ratio method. The performance of this method is first evaluated on whispered speech data from the CHAINS corpus. The second set of experiments are conducted on the cell phone corpus of whispered speech. This corpus is collected using a set up that is used commercially for handling public transactions. The proposed whisper speech recognition system exhibits reasonably better performance when compared to several conventional methods. The results shown indicate the possibility of a whispered speech recognition system for cell phone based transactions.

  1. Comparison of scoliosis measurements based on three-dimensional vertebra vectors and conventional two-dimensional measurements: advantages in evaluation of prognosis and surgical results.

    PubMed

    Illés, Tamás; Somoskeöy, Szabolcs

    2013-06-01

    A new concept of vertebra vectors based on spinal three-dimensional (3D) reconstructions of images from the EOS system, a new low-dose X-ray imaging device, was recently proposed to facilitate interpretation of EOS 3D data, especially with regard to horizontal plane images. This retrospective study was aimed at the evaluation of the spinal layout visualized by EOS 3D and vertebra vectors before and after surgical correction, the comparison of scoliotic spine measurement values based on 3D vertebra vectors with measurements using conventional two-dimensional (2D) methods, and an evaluation of horizontal plane vector parameters for their relationship with the magnitude of scoliotic deformity. 95 patients with adolescent idiopathic scoliosis operated according to the Cotrel-Dubousset principle were subjected to EOS X-ray examinations pre- and postoperatively, followed by 3D reconstructions and generation of vertebra vectors in a calibrated coordinate system to calculate vector coordinates and parameters, as published earlier. Differences in values of conventional 2D Cobb methods and methods based on vertebra vectors were evaluated by means comparison T test and relationship of corresponding parameters was analysed by bivariate correlation. Relationship of horizontal plane vector parameters with the magnitude of scoliotic deformities and results of surgical correction were analysed by Pearson correlation and linear regression. In comparison to manual 2D methods, a very close relationship was detectable in vertebra vector-based curvature data for coronal curves (preop r 0.950, postop r 0.935) and thoracic kyphosis (preop r 0.893, postop r 0.896), while the found small difference in L1-L5 lordosis values (preop r 0.763, postop r 0.809) was shown to be strongly related to the magnitude of corresponding L5 wedge. The correlation analysis results revealed strong correlation between the magnitude of scoliosis and the lateral translation of apical vertebra in horizontal plane. The horizontal plane coordinates of the terminal and initial points of apical vertebra vectors represent this (r 0.701; r 0.667). Less strong correlation was detected in the axial rotation of apical vertebras and the magnitudes of the frontal curves (r 0.459). Vertebra vectors provide a key opportunity to visualize spinal deformities in all three planes simultaneously. Measurement methods based on vertebral vectors proved to be just as accurate and reliable as conventional measurement methods for coronal and sagittal plane parameters. In addition, the horizontal plane display of the curves can be studied using the same vertebra vectors. Based on the vertebra vectors data, during the surgical treatment of spinal deformities, the diminution of the lateral translation of the vertebras seems to be more important in the results of the surgical correction than the correction of the axial rotation.

  2. Fluence-based and microdosimetric event-based methods for radiation protection in space

    NASA Technical Reports Server (NTRS)

    Curtis, Stanley B.; Meinhold, C. B. (Principal Investigator)

    2002-01-01

    The National Council on Radiation Protection and Measurements (NCRP) has recently published a report (Report #137) that discusses various aspects of the concepts used in radiation protection and the difficulties in measuring the radiation environment in spacecraft for the estimation of radiation risk to space travelers. Two novel dosimetric methodologies, fluence-based and microdosimetric event-based methods, are discussed and evaluated, along with the more conventional quality factor/LET method. It was concluded that for the present, any reason to switch to a new methodology is not compelling. It is suggested that because of certain drawbacks in the presently-used conventional method, these alternative methodologies should be kept in mind. As new data become available and dosimetric techniques become more refined, the question should be revisited and that in the future, significant improvement might be realized. In addition, such concepts as equivalent dose and organ dose equivalent are discussed and various problems regarding the measurement/estimation of these quantities are presented.

  3. Manufacture and evaluation of Nb/sub 3/Sn conductors fabricated by the MJR method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDonald, W.K.; Curtis, C.W.; Scanlan, R.M.

    1982-11-23

    The bronze matrix/niobium filament process has become established as a commercially viable method for producing multifilamentary Nb/sub 3/Sn superconductors. This paper describes a new method, the Modified Jelly-Roll (MJR) approach, which can produce a structure similar to that in a conventionally fabricated multifilamentary Nb/sub 3/Sn conductor. This approach utilizes alternate sheets of niobium expanded metal and bronze, which are rolled into a jelly-roll configuration and then extruded. During extrusion and subsequent drawing, the junctures in the niobium are elongated and the material develops a filamentary structure. This method may offer significant advantages in terms of reduced fabrication time and costmore » over the conventional approach. Results of a manufacturing development program will be presented in which two lengths of conductor were made to High-Field Test Facility conductor specifications. In addition, critical current and transition temperature measurements of the sub-elements used to construct the HFTF-type lengths will be reported.« less

  4. [Value of combined conventional and contrast enhanced sonography in the evaluation of hepatic disorders].

    PubMed

    Tranquart, F; Bleuzen, A; Kissel, A

    2004-06-01

    To assess the value of combined conventional and contrast-material enhanced sonography for the characterization of focal liver lesions. Simultaneous imaging with grey scale and contrast enhanced US was performed in 90 patients following Levovist injection (Schering, Berlin, Germany) using the "Agent Detection Imaging" method (ADI, Siemens-Acuson, Mountain View, USA). US scanning was performed at least 4 minutes after contrast injection with review of both grayscale and contrast enhanced modes. Results for detection and characterization of lesions were compared to the selected gold standard imaging modality (CT or MRI). Final diagnoses included: 20 normal examinations, 41 patients with metastases, 6 patients with hepatocellular carcinoma, 13 patients with hemangioma, 6 patients with other benign lesions, 4 patients with cysts and 6 patients with two types of lesions. Delayed phase contrast enhanced US allowed diagnosis of all lesions except for one metastasis and all hepatocellular carcinomas. While the diagnosis of hepatoma could not be confirmed, the features suggested a malignant etiology. For 7 patients with metastases, more lesions were detected at ADI (4.9 lesions) than at conventional US (1.1 lesion). For 3 patients, CT showed more lesions than ADI US (3.3 versus 1.6 lesions). The accuracy of ADI US for differentiating between benign and malignant lesions was 98.7% compared to 49.6% for conventional US (p<0.001). The total number of lesions detected at ADI US was higher (p<0.01) than at conventional US and not significantly different from that obtained by the gold standard reference methods. Complete characterization was achieved in 92.2% of cases with ADI US compared to 59.2% with conventional US (p<0.001). Contrast-material enhanced US combined with conventional US markedly improves the diagnostic accuracy of US in terms of lesion detection and characterization.

  5. Liquid-based cytology for primary cervical cancer screening: a multi-centre study

    PubMed Central

    Monsonego, J; Autillo-Touati, A; Bergeron, C; Dachez, R; Liaras, J; Saurel, J; Zerat, L; Chatelain, P; Mottot, C

    2001-01-01

    The aim of this six-centre, split-sample study was to compare ThinPrep fluid-based cytology to the conventional Papanicolaou smear. Six cytopathology laboratories and 35 gynaecologists participated. 5428 patients met the inclusion criteria (age > 18 years old, intact cervix, informed consent). Each cervical sample was used first to prepare a conventional Pap smear, then the sampling device was rinsed into a PreservCyt vial, and a ThinPrep slide was made. Screening of slide pairs was blinded (n = 5428). All non-negative concordant cases (n = 101), all non-concordant cases (n = 206), and a 5% random sample of concordant negative cases (n = 272) underwent review by one independent pathologist then by the panel of 6 investigators. Initial (blinded) screening results for ThinPrep and conventional smears were correlated. Initial diagnoses were correlated with consensus cytological diagnoses. Differences in disease detection were evaluated using McNemar's test. On initial screening, 29% more ASCUS cases and 39% more low-grade squamous intraepithelial lesions (LSIL) and more severe lesions (LSIL+) were detected on the ThinPrep slides than on the conventional smears (P = 0.001), including 50% more LSIL and 18% more high-grade SIL (HSIL). The ASCUS:SIL ratio was lower for the ThinPrep method (115:132 = 0.87:1) than for the conventional smear method (89:94 = 0.95:1). The same trend was observed for the ASCUS/AGUS:LSIL ratio. Independent and consensus review confirmed 145 LSIL+ diagnoses; of these, 18% more had been detected initially on the ThinPrep slides than on the conventional smears (P = 0.041). The ThinPrep Pap Test is more accurate than the conventional Pap test and has the potential to optimize the effectiveness of primary cervical cancer screening. © 2001 Cancer Research Campaign http://www.bjcancer.com PMID:11161401

  6. Feasibility of Acoustic Doppler Velocity Meters for the Production of Discharge Records from U.S. Geological Survey Streamflow-Gaging Stations

    USGS Publications Warehouse

    Morlock, Scott E.; Nguyen, Hieu T.; Ross, Jerry H.

    2002-01-01

    It is feasible to use acoustic Doppler velocity meters (ADVM's) installed at U.S. Geological Survey (USGS) streamflow-gaging stations to compute records of river discharge. ADVM's are small acoustic current meters that use the Doppler principle to measure water velocities in a two-dimensional plane. Records of river discharge can be computed from stage and ADVM velocity data using the 'index velocity' method. The ADVM-measured velocities are used as an estimator or 'index' of the mean velocity in the channel. In evaluations of ADVM's for the computation of records of river discharge, the USGS installed ADVM's at three streamflow-gaging stations in Indiana: Kankakee River at Davis, Fall Creek at Millersville, and Iroquois River near Foresman. The ADVM evaluation study period was from June 1999 to February 2001. Discharge records were computed, using ADVM data from each station. Discharge records also were computed using conventional stage-discharge methods of the USGS. The records produced from ADVM and conventional methods were compared with discharge record hydrographs and statistics. Overall, the records compared closely from the Kankakee River and Fall Creek stations. For the Iroquois River station, variable backwater was present and affected the comparison; because the ADVM record compensates for backwater, the ADVM record may be superior to the conventional record. For the three stations, the ADVM records were judged to be of a quality acceptable to USGS standards for publications and near realtime ADVM-computed discharges are served on USGS real-time data World Wide Web pages.

  7. MALDI-TOF mass spectrometry-based identification of group A Streptococcus isolated from areas of the 2011 scarlet fever outbreak in china.

    PubMed

    Xiao, Di; You, Yuanhai; Bi, Zhenwang; Wang, Haibin; Zhang, Yongchan; Hu, Bin; Song, Yanyan; Zhang, Huifang; Kou, Zengqiang; Yan, Xiaomei; Zhang, Menghan; Jin, Lianmei; Jiang, Xihong; Su, Peng; Bi, Zhenqiang; Luo, Fengji; Zhang, Jianzhong

    2013-03-01

    There was a dramatic increase in scarlet fever cases in China from March to July 2011. Group A Streptococcus (GAS) is the only pathogen known to cause scarlet fever. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) coupled to Biotyper system was used for GAS identification in 2011. A local reference database (LRD) was constructed, evaluated and used to identify GAS isolates. The 75 GAS strains used to evaluate the LRD were all identified correctly. Of the 157 suspected β-hemolytic strains isolated from 298 throat swab samples, 127 (100%) and 120 (94.5%) of the isolates were identified as GAS by the MALDI-TOF MS system and the conventional bacitracin sensitivity test method, respectively. All 202 (100%) isolates were identified at the species level by searching the LRD, while 182 (90.1%) were identified by searching the original reference database (ORD). There were statistically significant differences with a high degree of credibility at species level (χ(2)=6.052, P<0.05 between the LRD and ORD). The test turnaround time was shortened 36-48h, and the cost of each sample is one-tenth of the cost of conventional methods. Establishing a domestic database is the most effective way to improve the identification efficiency using a MALDI-TOF MS system. MALDI-TOF MS is a viable alternative to conventional methods and may aid in the diagnosis and surveillance of GAS. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Evaluation of Three MALDI-TOF Mass Spectrometry Libraries for the Identification of Filamentous Fungi in Three Clinical Microbiology Laboratories in Manitoba, Canada.

    PubMed

    Stein, Markus; Tran, Vanessa; Nichol, Kimberly A; Lagacé-Wiens, Philippe; Pieroni, Peter; Adam, Heather J; Turenne, Christine; Walkty, Andrew J; Normand, Anne-Cécile; Hendrickx, Marijke; Piarroux, Renaud; Karlowsky, James A

    2018-06-12

    Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is commonly used by clinical microbiology laboratories to identify bacterial pathogens and yeasts, but not for the identification of moulds. Recent progress in extraction protocols and the composition of comparative libraries support potential application of MALDI-TOF MS for mould identification in clinical microbiology laboratories. We evaluated the performance of the Bruker Microflex ™ MALDI-TOF MS instrument (Billerica, MA, USA) to identify clinical isolates and reference strains of moulds using three libraries, the Bruker mould library, the National Institutes of Health (NIH) library, and the Mass Spectrometry Identification (MSI) online library, and compared those results to conventional (morphological) and molecular (18S/ITS; gold standard) identification methods. All three libraries demonstrated greater accuracy in genus identification (≥94.9%) than conventional methods (86.4%). MALDI-TOF MS identified 73.3% of isolates to species-level compared to only 31.7% by conventional methods. The MSI library demonstrated the highest rate of species-level identification (72.0%) compared to NIH (19.5%) and Bruker (13.6%) libraries. Greater than 20% of moulds remained unidentified to species-level by all three MALDI-TOF MS libraries primarily because of library limitations or imperfect spectra. The overall identification rate of each MALDI-TOF MS library depended on the number of species and the number of spectra representing each species in the library. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. One device, one equation: the simplest way to objectively evaluate psoriasis severity.

    PubMed

    Choi, Jae Woo; Kim, Bo Ri; Choi, Chong Won; Youn, Sang Woong

    2015-02-01

    The erythema, scale and thickness of psoriasis lesions could be converted to bioengineering parameters. An objective psoriasis severity assessment is advantageous in terms of accuracy and reproducibility over conventional severity assessment. We aimed to formulate an objective psoriasis severity index with a single bioengineering device that can possibly substitute the conventional subjective Psoriasis Severity Index. A linear regression analysis was performed to derive the formula with the subjective Psoriasis Severity Index as the dependent variable and various bioengineering parameters determined from 157 psoriasis lesions as independent variables. The construct validity of the objective Psoriasis Severity Index was evaluated with an additional 30 psoriasis lesions through a Pearson correlation analysis. The formula is composed of hue and brightness, which are sufficiently obtainable with a Colorimeter alone. A very strong positive correlation was found between the objective and subjective psoriasis severity indexes. The objective Psoriasis Severity Index is a novel, practical and valid assessment method that can substitute the conventional one. Combined with subjective area assessment, it could further replace the Psoriasis Area and Severity Index which is currently most popular. © 2014 Japanese Dermatological Association.

  10. Comparison of Radial Shockwaves and Conventional Physiotherapy for Treating Plantar Fasciitis

    PubMed Central

    Greve, Júlia Maria D’Andréa; Grecco, Marcus Vinicius; Santos-Silva, Paulo Roberto

    2009-01-01

    OBJECTIVE: To compare radial shockwave treatment and conventional physiotherapy for plantar fasciitis. MATERIALS AND METHODS: Thirty-two patients with plantar fasciitis were included in this study. They were randomly divided into two groups. Group 1 was composed of 16 patients who underwent 10 physiotherapy sessions each, consisting of ultrasound, kinesiotherapy and instruction for stretching exercises at home. Group 2 was composed of 16 patients who underwent three applications of radial shockwaves (once a week) and received instruction for stretching exercises at home. Pain and ability to function were evaluated before treatment, immediately afterwards, and three months later. The mean age of the patients was 47.3 ± 10.3 years (range 25–68); 81% were female, 87% were overweight, 56% had bilateral impairment, and 75% used analgesics regularly. RESULTS: Both treatments were effective for pain reduction and for improving the functional abilities of patients with plantar fasciitis. The effect of the shockwaves was apparent sooner than physiotherapy after the onset of treatment. CONCLUSION: Shockwave treatment was no more effective than conventional physiotherapy treatment when evaluated three months after the end of treatment. PMID:19219314

  11. Comparative study of receiver-side ghost wavefield attenuation on different marine acquisition configurations

    NASA Astrophysics Data System (ADS)

    Zhang, Hao; Liu, Qiancheng; Li, Hongyuan; Zhang, Yi

    2018-04-01

    In marine seismic exploration, the ghost energies (down-going waves), which arise from the reflection at the surface, are often treated as unwanted signals for data processing. The ghost wave fields interfere with the desired primary signals, leads to frequency notches and attenuation of low frequencies, which in turn downgrade the resolution of the recorded seismic data. There are two main categories of methods to solve the ghost or the so-called notch problem: the non-conventional acquisition configuration-based technique and a deghosting algorithm-based solution. The variable-depth streamer (VDS) acquisition solution is one of the most representative methods in the first category, which has become a popular solution for marine seismic acquisition to obtain broad data bandwidth. However, this approach is not as economic as the conventional constant depth streamer (CDS) acquisition, due to the precise control of the towing streamer. In addition, there are large quantities of conventionally-towed legacy data stored in the data library. Applying receiver deghosting to the CDS data thus becomes a more economical method. In theory, both types of data after deghosting should have the same bandwidth and S/N ratio, but in reality they are different. In this paper, we conduct a comparative study and evaluation to apply receiver deghosting to a set of real 2D marine data including both types of acquisition (CDS and VDS) corresponding to the same geology. The deghosting algorithm we employed is a self-sustained, inversion-based approach operated in the τ-p domain. This evaluation can help us to understand two questions: whether the VDS acquisition has more broadband characteristics compared to conventional CDS acquisition after deghosting, and whether we can achieve the identical or similar data quality (e.g., S/N ratio) through the proper deghosting algorithm for both types of data. The comparative results are illustrated and discussed.

  12. Utility of Vibratory Stimulation for Reducing Intraoral Injection Pain.

    PubMed

    Erdogan, Ozgur; Sinsawat, Anatachai; Pawa, Sudeep; Rintanalert, Duangtawan; Vuddhakanok, Suchada

    2018-01-01

    Intraoral local anesthesia injection is often perceived as a painful and anxiety-causing dental procedure. Vibration stimulus is one of the nonpharmacologic methods used to reduce unwanted sensations of local anesthesia injection. This clinical study evaluated the effectiveness of a recently introduced vibratory stimulation device in intraoral local anesthesia administration. Thirty-two subjects underwent 2 maxillary local anesthesia injections in 2 different sessions: 1 with conventional techniques and 1 with the aid of a vibratory stimulation device (DentalVibe). The pain levels were evaluated with a visual analog scale and the Wong-Baker FACES Pain Rating Scale. The subjects were asked to choose the preferred method for future injections. The data were evaluated statistically. There were no significant differences between the 2 injection methods with regard to either pain evaluation method. The preference of the subjects regarding future injection technique was evenly distributed between the groups. The vibratory stimulation device used in this study did not provide any reduction in pain level associated with maxillary infiltration local anesthesia administration.

  13. Comparative evaluation of anchorage loss between self-ligating appliance and Conventional pre-adjusted edgewise appliance using sliding mechanics – A retrospective study

    PubMed Central

    Juneja, Pankaj; Shivaprakash, G.; Chopra, S.S.; Kambalyal, P.B.

    2015-01-01

    Background Although a number of studies have been undertaken to evaluate the friction characteristics of self-ligating brackets, there have been only few studies which have actually evaluated the clinical efficiency of these self-ligating brackets. This study was done to evaluate the clinical efficiency of Passive SLB (Smart Clip) in terms of anchorage loss and total treatment duration by comparing it with a Conventional pre-adjusted edgewise (M.B.T.) bracket system. Methods This was a retrospective study in which the study sample comprised of ten patients treated with Passive SLB (Smart Clip, 0.022″) and ten patients treated with Conventional pre-adjusted edgewise (M.B.T.) bracket system (0.022″) who required therapeutic extraction of U/L first premolars as a part of their orthodontic treatment plan. Pretreatment and post treatment lateral cephalograms were taken to evaluate the amount of anchorage loss. The total time required to complete the treatment was also recorded. Results Anchorage loss observed with Passive SLB (Smart Clip) sagittally was 1.90 ± 0.68 mm in the maxilla and 1.90 ± 0.43 mm in the mandible and vertically was 0.52 ± 0.53 mm in the maxilla and 0.70 ± 0.69 mm in the mandible. Anchorage loss observed with Conventional pre-adjusted edgewise (M.B.T.) bracket system sagittally was 2.08 ± 0.43 mm in the maxilla and 1.95 ± 0.44 mm in the mandible and vertically was 0.50 ± 0.49 mm in the maxilla and 0.68 ± 0.53 mm in the mandible. The average time taken for the completion of treatment in Passive SLB (Smart Clip) and Conventional pre-adjusted edgewise (M.B.T.) bracket system was 14.0 ± 2.4 and 17.2 ± 2.6 months respectively. Conclusion There was no statistically significant difference in the quantum of anchor loss between Smart Clip self-ligating bracket system and Conventional pre-adjusted edgewise (M.B.T.) bracket system although Smart Clip self-ligating bracket system is efficient in reducing the overall treatment time. PMID:26843751

  14. Traditional use of indigenous mosquito-repellents to protect humans against mosquitoes and other insect bites in a rural community of Cameroon.

    PubMed

    Ntonifor, N N; Ngufor, C A; Kimbi, H K; Oben, B O

    2006-10-01

    To document and test the efficacy of indigenous traditional personal protection methods against mosquito bites and general nuisance. A prospective study based on a survey and field evaluation of selected plant-based personal protection methods against mosquito bites. Bolifamba, a rural setting of the Mount Cameroon region. A structured questionnaire was administered to 179 respondents and two anti-mosquito measures were tested under field conditions. Identified traditional anti-mosquito methods used by indigenes of Bolifamba. Two plants tested under field conditions were found to be effective. Of the 179 respondents, 88 (49.16%) used traditional anti-mosquito methods; 57 (64.77%) used plant-based methods while 31 (35.2%) used various petroleum oils. The rest of the respondents, 91 (50.8%) used conventional personal protection methods. Reasons for using traditional methods were because they were available, affordable and lack of known more effective alternatives. The demerits of these methods were: labourious to implement, stain dresses, produce a lot of smoke/ repulsive odours when used; those of conventional methods were lack of adequate information about them, high cost and non-availability. When the two most frequently used plants, Saccharum officinarium and Ocimum basilicum were evaluated under field conditions, each gave a better protection than the control. Most plants used against mosquitoes in the area are known potent mosquito repellents but others identified in the study warrant further research. The two tested under field conditions were effective though less than the commonly used commercial diethyltoluamide.

  15. Quantitative assessment of tumour extraction from dermoscopy images and evaluation of computer-based extraction methods for an automatic melanoma diagnostic system.

    PubMed

    Iyatomi, Hitoshi; Oka, Hiroshi; Saito, Masataka; Miyake, Ayako; Kimoto, Masayuki; Yamagami, Jun; Kobayashi, Seiichiro; Tanikawa, Akiko; Hagiwara, Masafumi; Ogawa, Koichi; Argenziano, Giuseppe; Soyer, H Peter; Tanaka, Masaru

    2006-04-01

    The aims of this study were to provide a quantitative assessment of the tumour area extracted by dermatologists and to evaluate computer-based methods from dermoscopy images for refining a computer-based melanoma diagnostic system. Dermoscopic images of 188 Clark naevi, 56 Reed naevi and 75 melanomas were examined. Five dermatologists manually drew the border of each lesion with a tablet computer. The inter-observer variability was evaluated and the standard tumour area (STA) for each dermoscopy image was defined. Manual extractions by 10 non-medical individuals and by two computer-based methods were evaluated with STA-based assessment criteria: precision and recall. Our new computer-based method introduced the region-growing approach in order to yield results close to those obtained by dermatologists. The effectiveness of our extraction method with regard to diagnostic accuracy was evaluated. Two linear classifiers were built using the results of conventional and new computer-based tumour area extraction methods. The final diagnostic accuracy was evaluated by drawing the receiver operating curve (ROC) of each classifier, and the area under each ROC was evaluated. The standard deviations of the tumour area extracted by five dermatologists and 10 non-medical individuals were 8.9% and 10.7%, respectively. After assessment of the extraction results by dermatologists, the STA was defined as the area that was selected by more than two dermatologists. Dermatologists selected the melanoma area with statistically smaller divergence than that of Clark naevus or Reed naevus (P = 0.05). By contrast, non-medical individuals did not show this difference. Our new computer-based extraction algorithm showed superior performance (precision, 94.1%; recall, 95.3%) to the conventional thresholding method (precision, 99.5%; recall, 87.6%). These results indicate that our new algorithm extracted a tumour area close to that obtained by dermatologists and, in particular, the border part of the tumour was adequately extracted. With this refinement, the area under the ROC increased from 0.795 to 0.875 and the diagnostic accuracy showed an increase of approximately 20% in specificity when the sensitivity was 80%. It can be concluded that our computer-based tumour extraction algorithm extracted almost the same area as that obtained by dermatologists and provided improved computer-based diagnostic accuracy.

  16. In vitro starch digestibility and expected glycemic index of pound cakes baked in two-cycle microwave-toaster and conventional oven.

    PubMed

    García-zaragoza, Francisco J; Sánchez-Pardo, María E; Ortiz-Moreno, Alicia; Bello-Pérez, Luis A

    2010-11-01

    Bread baking technology has an important effect on starch digestibility measured as its predicted glycemic index tested in vitro. The aim of this work was to evaluate the changes in predicted glycemic index of pound cake baked in a two-cycle microwave toaster and a conventional oven. The glycemic index was calculated from hydrolysis index values by the Granfeldt method. Non-significant differences (P > 0.05) were found in hydrolysis index (60.67 ± 3.96 for the product baked in microwave oven and 65.94 ± 4.09 for the product baked in conventional oven) and predicted glycemic index content (60.5 for product baked in microwave oven and 65 for the product baked in conventional oven) in freshly-baked samples. Results clearly demonstrate that the baking pound cake conventional process could be replicated using a two-cycle multifunction microwave oven, reducing the traditional baking time. Further research is required in order to achieve pound cake crumb uniformity.

  17. Evaluating gull diets: A comparison of conventional methods and stable isotope analysis

    USGS Publications Warehouse

    Weiser, Emily L.; Powell, Abby N.

    2011-01-01

    Samples such as regurgitated pellets and food remains have traditionally been used in studies of bird diets, but these can produce biased estimates depending on the digestibility of different foods. Stable isotope analysis has been developed as a method for assessing bird diets that is not biased by digestibility. These two methods may provide complementary or conflicting information on diets of birds, but are rarely compared directly. We analyzed carbon and nitrogen stable isotope ratios of feathers of Glaucous Gull (Larus hyperboreus) chicks from eight breeding colonies in northern Alaska, and used a Bayesian mixing model to generate a probability distribution for the contribution of each food group to diets. We compared these model results with probability distributions from conventional diet samples (pellets and food remains) from the same colonies and time periods. Relative to the stable isotope estimates, conventional analysis often overestimated the contributions of birds and small mammals to gull diets and often underestimated the contributions of fish and zooplankton. Both methods gave similar estimates for the contributions of scavenged caribou, miscellaneous marine foods, and garbage to diets. Pellets and food remains therefore may be useful for assessing the importance of garbage relative to certain other foods in diets of gulls and similar birds, but are clearly inappropriate for estimating the potential impact of gulls on birds, small mammals, or fish. However, conventional samples provide more species-level information than stable isotope analysis, so a combined approach would be most useful for diet analysis and assessing a predator's impact on particular prey groups.

  18. Three-dimensional sampling perfection with application-optimised contrasts using a different flip angle evolutions sequence for routine imaging of the spine: preliminary experience

    PubMed Central

    Tins, B; Cassar-Pullicino, V; Haddaway, M; Nachtrab, U

    2012-01-01

    Objectives The bulk of spinal imaging is still performed with conventional two-dimensional sequences. This study assesses the suitability of three-dimensional sampling perfection with application-optimised contrasts using a different flip angle evolutions (SPACE) sequence for routine spinal imaging. Methods 62 MRI examinations of the spine were evaluated by 2 examiners in consensus for the depiction of anatomy and presence of artefact. We noted pathologies that might be missed using the SPACE sequence only or the SPACE and a sagittal T1 weighted sequence. The reference standards were sagittal and axial T1 weighted and T2 weighted sequences. At a later date the evaluation was repeated by one of the original examiners and an additional examiner. Results There was good agreement of the single evaluations and consensus evaluation for the conventional sequences: κ>0.8, confidence interval (CI)>0.6–1.0. For the SPACE sequence, depiction of anatomy was very good for 84% of cases, with high interobserver agreement, but there was poor interobserver agreement for other cases. For artefact assessment of SPACE, κ=0.92, CI=0.92–1.0. The SPACE sequence was superior to conventional sequences for depiction of anatomy and artefact resistance. The SPACE sequence occasionally missed bone marrow oedema. In conjunction with sagittal T1 weighted sequences, no abnormality was missed. The isotropic SPACE sequence was superior to conventional sequences in imaging difficult anatomy such as in scoliosis and spondylolysis. Conclusion The SPACE sequence allows excellent assessment of anatomy owing to high spatial resolution and resistance to artefact. The sensitivity for bone marrow abnormalities is limited. PMID:22374284

  19. Clinical utility of indigenously formulated single-vial lyophilized HYNIC-TOC kit in evaluating Gastro-entero Pancreatic neuro endocrine tumours

    PubMed Central

    Shinto, Ajit S; Kamaleshwaran, K; Vyshak, K; Sudhakar, Natarajan; Banerjee, Sharmila; Korde, Aruna; Samuel, Grace; Mallia, Madhav

    2014-01-01

    Objective(s): The objective of this study was to evaluate the performance and utility of 99mTc HYNIC-TOC planar scintigraphy and SPECT/CT in the diagnosis, staging and management of gastroenteropancreatic neuroendocrine tumors (GPNETs). Methods: 22 patients (median age, 46 years) with histologically proven gastro- entero- pancreatic NETs underwent 99mTc HYNIC-TOC whole body scintigraphy and regional SPECT/CT as indicated. Scanning was performed after injection of 370-550 MBq (10-15 mCi) of 99mTc HYNIC-TOC intravenously. Images were evaluated by two experienced nuclear medicine physicians both qualitatively as well as semi quantitatively (tumor to background and tumor to normal liver ratios on SPECT -CT images). Results of SPECT/CT were compared with the results of conventional imaging. Histopathology results and follow-up somatostatin receptor scintigraphy with 99mTc HYNIC TOC or conventional imaging with biochemical markers were considered to be the reference standards. Results: 99mTc HYNIC TOC showed sensitivity and specificity of 87.5% and 85.7%, respectively, for primary tumor and 100% and 86% for metastases. It was better than conventional imaging modalities for the detection of both primary tumor (P<0.001) and metastases (P<0.0001). It changed the management strategy in 6 patients (31.8%) and supported management decisions in 8 patients (36.3%). Conclusion: 99mTc HYNIC TOC SPECT/CT appears to be a highly sensitive and specific modality for the detection and staging of GPNETs. It is better than conventional imaging for the evaluation of GPNETs and can have a significant impact on patient management and planning further therapeutic options. PMID:27408857

  20. Lost in processing? Perceived healthfulness, taste and caloric content of whole and processed organic food.

    PubMed

    Prada, Marília; Garrido, Margarida V; Rodrigues, David

    2017-07-01

    The "organic" claim explicitly informs consumers about the food production method. Yet, based on this claim, people often infer unrelated food attributes. The current research examined whether the perceived advantage of organic over conventional food generalizes across different organic food types. Compared to whole organic foods, processed organic foods are less available, familiar and prototypical of the organic food category. In two studies (combined N = 258) we investigated how both organic foods types were perceived in healthfulness, taste and caloric content when compared to their conventional alternatives. Participants evaluated images of both whole (e.g., lettuce) and processed organic food exemplars (e.g., pizza), and reported general evaluations of these food types. The association of these evaluations with individual difference variables - self-reported knowledge and consumption of organic food, and environmental concerns - was also examined. Results showed that organically produced whole foods were perceived as more healthful, tastier and less caloric than those produced conventionally, thus replicating the well-established halo effect of the organic claim in food evaluation. The organic advantage was more pronounced among individuals who reported being more knowledgeable about organic food, consumed it more frequently, and were more environmentally concerned. The advantage of the organic claim for processed foods was less clear. Overall, processed organic (vs. conventional) foods were perceived as tastier, more healthful (Study 1) or equally healthful (Study 2), but also as more caloric. We argue that the features of processed food may modulate the impact of the organic claim, and outline possible research directions to test this assumption. Uncovering the specific conditions in which food claims bias consumer's perceptions and behavior may have important implications for marketing, health and public-policy related fields. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. High pitch third generation dual-source CT: Coronary and Cardiac Visualization on Routine Chest CT

    PubMed Central

    Sandfort, Veit; Ahlman, Mark; Jones, Elizabeth; Selwaness, Mariana; Chen, Marcus; Folio, Les; Bluemke, David A.

    2016-01-01

    Background Chest CT scans are frequently performed in radiology departments but have not previously contained detailed depiction of cardiac structures. Objectives To evaluate myocardial and coronary visualization on high-pitch non-gated CT of the chest using 3rd generation dual-source computed tomography (CT). Methods Cardiac anatomy of patients who had 3rd generation, non-gated high pitch contrast enhanced chest CT and who also had prior conventional (low pitch) chest CT as part of a chest abdomen pelvis exam was evaluated. Cardiac image features were scored by reviewers blinded to diagnosis and pitch. Paired analysis was performed. Results 3862 coronary segments and 2220 cardiac structures were evaluated by two readers in 222 CT scans. Most patients (97.2%) had chest CT for oncologic evaluation. The median pitch was 2.34 (IQR 2.05, 2.65) in high pitch and 0.8 (IQR 0.8, 0.8) in low pitch scans (p<0.001). High pitch CT showed higher image visualization scores for all cardiovascular structures compared with conventional pitch scans (p<0.0001). Coronary arteries were visualized in 9 coronary segments per exam in high pitch scans versus 2 segments for conventional pitch (p<0.0001). Radiation exposure was lower in the high pitch group compared with the conventional pitch group (median CTDIvol 10.83 vs. 12.36 mGy and DLP 790 vs. 827 mGycm respectively, p <0.01 for both) with comparable image noise (p=0.43). Conclusion Myocardial structure and coronary arteries are frequently visualized on non-gated 3rd generation chest CT. These results raise the question of whether the heart and coronary arteries should be routinely interpreted on routine chest CT that is otherwise obtained for non-cardiac indications. PMID:27133589

  2. Performance of the Fecal Immunochemical Test for Colorectal Cancer Screening Using Different Stool-Collection Devices: Preliminary Results from a Randomized Controlled Trial.

    PubMed

    Shin, Hye Young; Suh, Mina; Baik, Hyung Won; Choi, Kui Son; Park, Boyoung; Jun, Jae Kwan; Hwang, Sang-Hyun; Kim, Byung Chang; Lee, Chan Wha; Oh, Jae Hwan; Lee, You Kyoung; Han, Dong Soo; Lee, Do-Hoon

    2016-11-15

    We are in the process of conducting a randomized trial to determine whether compliance with the fecal immunochemical test (FIT) for colorectal cancer screening differs according to the stool-collection method. This study was an interim analysis of the performance of two stool-collection devices (sampling bottle vs conventional container). In total, 1,701 individuals (age range, 50 to 74 years) were randomized into the sampling bottle group (intervention arm) or the conventional container group (control arm). In both groups, we evaluated the FIT positivity rate, the positive predictive value for advanced neoplasia, and the detection rate for advanced neoplasia. The FIT positivity rates were 4.1% for the sampling bottles and 2.0% for the conventional containers; these values were significantly different. The positive predictive values for advanced neoplasia in the sampling bottles and conventional containers were 11.1% (95% confidence interval [CI], -3.4 to 25.6) and 12.0% (95% CI, -0.7 to 24.7), respectively. The detection rates for advanced neoplasia in the sampling bottles and conventional containers were 4.5 per 1,000 persons (95% CI, 2.0 to 11.0) and 2.4 per 1,000 persons (95% CI, 0.0 to 5.0), respectively. The impact of these findings on FIT screening performance was unclear in this interim analysis. This impact should therefore be evaluated in the final analysis following the final enrollment period.

  3. Comparative Evaluation of Conventional and Accelerated Castings on Marginal Fit and Surface Roughness

    PubMed Central

    Jadhav, Vivek Dattatray; Motwani, Bhagwan K.; Shinde, Jitendra; Adhapure, Prasad

    2017-01-01

    Aims: The aim of this study was to evaluate the marginal fit and surface roughness of complete cast crowns made by a conventional and an accelerated casting technique. Settings and Design: This study was divided into three parts. In Part I, the marginal fit of full metal crowns made by both casting techniques in the vertical direction was checked, in Part II, the fit of sectional metal crowns in the horizontal direction made by both casting techniques was checked, and in Part III, the surface roughness of disc-shaped metal plate specimens made by both casting techniques was checked. Materials and Methods: A conventional technique was compared with an accelerated technique. In Part I of the study, the marginal fit of the full metal crowns as well as in Part II, the horizontal fit of sectional metal crowns made by both casting techniques was determined, and in Part III, the surface roughness of castings made with the same techniques was compared. Statistical Analysis Used: The results of the t-test and independent sample test do not indicate statistically significant differences in the marginal discrepancy detected between the two casting techniques. Results: For the marginal discrepancy and surface roughness, crowns fabricated with the accelerated technique were significantly different from those fabricated with the conventional technique. Conclusions: Accelerated casting technique showed quite satisfactory results, but the conventional technique was superior in terms of marginal fit and surface roughness. PMID:29042726

  4. Fluorometric Method for Determining the Efficiency of Spun-Glass Air Filtration Media

    PubMed Central

    Sullivan, James F.; Songer, Joseph R.; Mathis, Raymond G.

    1967-01-01

    The procedures and equipment needed to measure filtration efficiency by means of fluorescent aerosols are described. The filtration efficiency of individual lots of spun-glass air filtration medium or of entire air filtration systems employing such media was determined. Data relating to the comparative evaluation of spun-glass filter media by means of the fluorometric method described, as well as by conventional biological procedures, are presented. PMID:6031433

  5. Evaluation of the clinical efficacy of the PeTrack motion tracking system for respiratory gating in cardiac PET imaging

    NASA Astrophysics Data System (ADS)

    Manwell, Spencer; Chamberland, Marc J. P.; Klein, Ran; Xu, Tong; deKemp, Robert

    2017-03-01

    Respiratory gating is a common technique used to compensate for patient breathing motion and decrease the prevalence of image artifacts that can impact diagnoses. In this study a new data-driven respiratory gating method (PeTrack) was compared with a conventional optical tracking system. The performance of respiratory gating of the two systems was evaluated by comparing the number of respiratory triggers, patient breathing intervals and gross heart motion as measured in the respiratory-gated image reconstructions of rubidium-82 cardiac PET scans in test and control groups consisting of 15 and 8 scans, respectively. We found evidence suggesting that PeTrack is a robust patient motion tracking system that can be used to retrospectively assess patient motion in the event of failure of the conventional optical tracking system.

  6. Performance evaluation of a two detector camera for real-time video.

    PubMed

    Lochocki, Benjamin; Gambín-Regadera, Adrián; Artal, Pablo

    2016-12-20

    Single pixel imaging can be the preferred method over traditional 2D-array imaging in spectral ranges where conventional cameras are not available. However, when it comes to real-time video imaging, single pixel imaging cannot compete with the framerates of conventional cameras, especially when high-resolution images are desired. Here we evaluate the performance of an imaging approach using two detectors simultaneously. First, we present theoretical results on how low SNR affects final image quality followed by experimentally determined results. Obtained video framerates were doubled compared to state of the art systems, resulting in a framerate from 22 Hz for a 32×32 resolution to 0.75 Hz for a 128×128 resolution image. Additionally, the two detector imaging technique enables the acquisition of images with a resolution of 256×256 in less than 3 s.

  7. Application of LANDSAT and Skylab data for land use mapping in Italy. [emphasizing the Alps Mountains

    NASA Technical Reports Server (NTRS)

    Bodechtel, J.; Nithack, J.; Dibernardo, G.; Hiller, K.; Jaskolla, F.; Smolka, A.

    1975-01-01

    Utilizing LANDSAT and Skylab multispectral imagery of 1972 and 1973, a land use map of the mountainous regions of Italy was evaluated at a scale of 1:250,000. Seven level I categories were identified by conventional methods of photointerpretation. Images of multispectral scanner (MSS) bands 5 and 7, or equivalents were mainly used. Areas of less than 200 by 200 m were classified and standard procedures were established for interpretation of multispectral satellite imagery. Land use maps were produced for central and southern Europe indicating that the existing land use maps could be updated and optimized. The complexity of European land use patterns, the intensive morphology of young mountain ranges, and time-cost calculations are the reasons that the applied conventional techniques are superior to automatic evaluation.

  8. SAFT-assisted sound beam focusing using phased arrays (PA-SAFT) for non-destructive evaluation

    NASA Astrophysics Data System (ADS)

    Nanekar, Paritosh; Kumar, Anish; Jayakumar, T.

    2015-04-01

    Focusing of sound has always been a subject of interest in ultrasonic non-destructive evaluation. An integrated approach to sound beam focusing using phased array and synthetic aperture focusing technique (PA-SAFT) has been developed in the authors' laboratory. The approach involves SAFT processing on ultrasonic B-scan image collected by a linear array transducer using a divergent sound beam. The objective is to achieve sound beam focusing using fewer elements than the ones required using conventional phased array. The effectiveness of the approach is demonstrated on aluminium blocks with artificial flaws and steel plate samples with embedded volumetric weld flaws, such as slag and clustered porosities. The results obtained by the PA-SAFT approach are found to be comparable to those obtained by conventional phased array and full matrix capture - total focusing method approaches.

  9. Continuum of risk analysis methods to assess tillage system sustainability at the experimental plot level

    USDA-ARS?s Scientific Manuscript database

    The primary goal of this study was to evaluate the efficacy of stochastic dominance and stochastic efficiency with respect to a function (SERF) methodology for ranking conventional and conservation tillage systems using 14 years (1990-2003) of economic budget data collected from 36 plots at the Iowa...

  10. Conventional and digital radiographic assessment of tooth enamel de-/remineralization processes: an experimental study.

    PubMed

    Leite-Ribeiro, Patrícia; de Oliveira, Thais Feitosa Leitão; Mathias, Paula; Campo, Elisângela de Jesus; Sarmento, Viviane Almeida

    2014-01-01

    This study aimed to compare digital techniques for evaluating dental enamel de-/remineralization. Sixty extracted molars were subjected to a process of de- and remineralization. Radiographs were taken before and after each stage. These radiographs were evaluated by the conventional method and were then scanned and analyzed either with or without the use of image enhancement. Moreover, the gray levels (GLs) of the affected areas were measured. All methods exhibited low sensitivity and identical levels of specificity (99.4%). Analysis of the grayscale levels found statistically significant differences between the initial radiographs (P < 0.05). The mean GL of the carious group was significantly lower than that of the remineralized group. The GL did not differ significantly between the initial and final radiographs of the remineralized group, although the mean of the first group was lower than that of the second, which demonstrated that the remineralization process restored the normal density of the dental enamel. Measurement of the mean GL was sufficiently sensitive to detect small alterations in the surface of the enamel.

  11. Development of mass measurement equipment using an electronic mass-comparator for gravimetric preparation of reference gas mixtures

    NASA Astrophysics Data System (ADS)

    Matsumoto, Nobuhiro; Watanabe, Takuro; Maruyama, Masaaki; Horimoto, Yoshiyuki; Maeda, Tsuneaki; Kato, Kenji

    2004-06-01

    The gravimetric method is the most popular method for preparing reference gas mixtures with high accuracy. We have designed and manufactured novel mass measurement equipment for gravimetric preparation of reference gas mixtures. This equipment consists of an electronic mass-comparator with a maximum capacity of 15 kg and readability of 1 mg and an automatic cylinder exchanger. The structure of this equipment is simpler and the cost is much lower than a conventional mechanical knife-edge type large balance used for gravimetric preparation of primary gas mixtures in Japan. This cylinder exchanger can mount two cylinders alternatively on the weighing pan of the comparator. In this study, the performance of the equipment has been evaluated. At first, the linearity and repeatability of the mass measurement were evaluated using standard mass pieces. Then, binary gas mixtures of propane and nitrogen were prepared and compared with those prepared with the conventional knife-edge type balance. The comparison resulted in good consistency at the compatibility criterion described in ISO6143:2001.

  12. Retention of cardiopulmonary resuscitation skills after hands-only training versus conventional training in novices: a randomized controlled trial.

    PubMed

    Kim, Young Joon; Cho, Youngsuk; Cho, Gyu Chong; Ji, Hyun Kyung; Han, Song Yi; Lee, Jin Hyuck

    2017-06-01

    Cardiopulmonary resuscitation (CPR) training can improve performance during simulated cardiac arrest; however, retention of skills after training remains uncertain. Recently, hands-only CPR has been shown to be as effective as conventional CPR. The purpose of this study is to compare the retention rate of CPR skills in laypersons after hands-only or conventional CPR training. Participants were randomly assigned to 1 of 2 CPR training methods: 80 minutes of hands-only CPR training or 180 minutes of conventional CPR training. Each participant's CPR skills were evaluated at the end of training and 3 months thereafter using the Resusci Anne manikin with a skill-reporting software. In total, 252 participants completed training; there were 125 in the hands-only CPR group and 127 in the conventional CPR group. After 3 months, 118 participants were randomly selected to complete a post-training test. The hands-only CPR group showed a significant decrease in average compression rate (P=0.015), average compression depth (P=0.031), and proportion of adequate compression depth (P=0.011). In contrast, there was no difference in the skills of the conventional CPR group after 3 months. Conventional CPR training appears to be more effective for the retention of chest compression skills than hands-only CPR training; however, the retention of artificial ventilation skills after conventional CPR training is poor.

  13. Application effect of sterile normal saline ice for post-partum hemorrhage at the time of cesarean delivery: A retrospective review.

    PubMed

    Cheng, Wenjing; Wang, Qiushi; Zhang, Zhenyu

    2016-10-01

    Post-partum hemorrhage (PPH) is a common complication of cesarean sections (CS) and affects maternal and newborn health. We used a new method to control bleeding and compared its efficacy with conventional methods. Eighty-six women who experienced PPH with volume of bleeding over 1000 mL in CS between January 2008 and January 2012 were chosen as samples. Thirty-three underwent the new method in which normal saline ice blocks are placed in the uterus, and 53 underwent the conventional method. We evaluated blood loss, volume of transfusion and complications. Patients who were treated with ice blocks had better hemostatic efficacy than those who underwent the conventional method (1450 ± 251.9 mL vs 1800 ± 278.9 mL; P < 0.001); they also had less blood transfusion (806.1 ± 242.3 mL vs 1222.6 ± 308.0 mL; P < 0.001), lower rate of hysterectomy and infection (3.03% vs 5.66%; P = 0.971; 0% vs 7.55%; P = 0.276), and shorter duration of hospital stay (5.3 ± 0.5 days vs 7.6 ± 3.0 days; P < 0.001). PPH in CS can be treated with peeled sterile normal saline ice blocks, a simple and reliable method for stopping bleeding. Nonetheless, there needs to be a large randomized control trial for confirmation. © 2016 Japan Society of Obstetrics and Gynecology.

  14. Methods of data collection and analysis for the economic evaluation alongside a national, multi-centre trial in the UK: Conventional ventilation or ECMO for Severe Adult Respiratory Failure (CESAR)

    PubMed Central

    Thalanany, Mariamma M; Mugford, Miranda; Hibbert, Clare; Cooper, Nicola J; Truesdale, Ann; Robinson, Steven; Tiruvoipati, Ravindranath; Elbourne, Diana R; Peek, Giles J; Clemens, Felicity; Hardy, Polly; Wilson, Andrew

    2008-01-01

    Background Extracorporeal Membrane Oxygenation (ECMO) is a technology used in treatment of patients with severe but potentially reversible respiratory failure. A multi-centre randomised controlled trial (CESAR) was funded in the UK to compare care including ECMO with conventional intensive care management. The protocol and funding for the CESAR trial included plans for economic data collection and analysis. Given the high cost of treatment, ECMO is considered an expensive technology for many funding systems. However, conventional treatment for severe respiratory failure is also one of the more costly forms of care in any health system. Methods/Design The objectives of the economic evaluation are to compare the costs of a policy of referral for ECMO with those of conventional treatment; to assess cost-effectiveness and the cost-utility at 6 months follow-up; and to assess the cost-utility over a predicted lifetime. Resources used by patients in the trial are identified. Resource use data are collected from clinical report forms and through follow up interviews with patients. Unit costs of hospital intensive care resources are based on parallel research on cost functions in UK NHS intensive care units. Other unit costs are based on published NHS tariffs. Cost effectiveness analysis uses the outcome: survival without severe disability. Cost utility analysis is based on quality adjusted life years gained based on the Euroqol EQ-5D at 6 months. Sensitivity analysis is planned to vary assumptions about transport costs and method of costing intensive care. Uncertainty will also be expressed in analysis of individual patient data. Probabilities of cost effectiveness given different funding thresholds will be estimated. Discussion In our view it is important to record our methods in detail and present them before publication of the results of the trial so that a record of detail not normally found in the final trial reports can be made available in the public domain. Trial Registrations The CESAR trial registration number is ISRCTN47279827. PMID:18447931

  15. Comparing 3D foot scanning with conventional measurement methods.

    PubMed

    Lee, Yu-Chi; Lin, Gloria; Wang, Mao-Jiun J

    2014-01-01

    Foot dimension information on different user groups is important for footwear design and clinical applications. Foot dimension data collected using different measurement methods presents accuracy problems. This study compared the precision and accuracy of the 3D foot scanning method with conventional foot dimension measurement methods including the digital caliper, ink footprint and digital footprint. Six commonly used foot dimensions, i.e. foot length, ball of foot length, outside ball of foot length, foot breadth diagonal, foot breadth horizontal and heel breadth were measured from 130 males and females using four foot measurement methods. Two-way ANOVA was performed to evaluate the sex and method effect on the measured foot dimensions. In addition, the mean absolute difference values and intra-class correlation coefficients (ICCs) were used for precision and accuracy evaluation. The results were also compared with the ISO 20685 criteria. The participant's sex and the measurement method were found (p < 0.05) to exert significant effects on the measured six foot dimensions. The precision of the 3D scanning measurement method with mean absolute difference values between 0.73 to 1.50 mm showed the best performance among the four measurement methods. The 3D scanning measurements showed better measurement accuracy performance than the other methods (mean absolute difference was 0.6 to 4.3 mm), except for measuring outside ball of foot length and foot breadth horizontal. The ICCs for all six foot dimension measurements among the four measurement methods were within the 0.61 to 0.98 range. Overall, the 3D foot scanner is recommended for collecting foot anthropometric data because it has relatively higher precision, accuracy and robustness. This finding suggests that when comparing foot anthropometric data among different references, it is important to consider the differences caused by the different measurement methods.

  16. Identification of the traditional methods of newborn mothers regarding jaundice in Turkey.

    PubMed

    Aydin, Diler; Karaca Ciftci, Esra; Karatas, Hulya

    2014-02-01

    To detect traditional methods applied for the treatment of newborn jaundice by mothers in Turkey. Traditional methods are generally used in our society. Instead of using medical services, people often use already-known traditional methods to treat the disease. In such cases, the prognosis of the disease generally becomes worse, the treatment period longer and healthcare costs higher, and more medicine is used. A cross-sectional descriptive study. The participants of this study were 229 mothers with newborn babies aged 0-28 days in one university hospital and one public children's hospital in Sanliurfa. The study was conducted between March and May 2012. In this research, the Beliefs and Traditional Methods of Mothers for Jaundice Questionnaire, which was formed by searching the relevant literature, is used as a data collection tool. The data are evaluated by percentage distributions. Mothers apply conventional practices in cases of health problems such as jaundice, and application of these methods is important to mothers. Moreover, mothers reported applying hazardous conventional methods in cases of neonatal jaundice, such as cutting the area between the baby's eyebrows with a blade, cutting the back of the ear and the body and burning the body, which are not applied in different cultures. Education regarding the effects of conventional methods being applied in families should be provided, and the results of this study should serve to guide further studies in assessing the effects of such education. This approach can support beneficial practices involving individual care and prevent the negative health effects of hazardous practices. © 2013 John Wiley & Sons Ltd.

  17. Shack-Hartmann wavefront sensor with large dynamic range by adaptive spot search method.

    PubMed

    Shinto, Hironobu; Saita, Yusuke; Nomura, Takanori

    2016-07-10

    A Shack-Hartmann wavefront sensor (SHWFS) that consists of a microlens array and an image sensor has been used to measure the wavefront aberrations of human eyes. However, a conventional SHWFS has finite dynamic range depending on the diameter of the each microlens. The dynamic range cannot be easily expanded without a decrease of the spatial resolution. In this study, an adaptive spot search method to expand the dynamic range of an SHWFS is proposed. In the proposed method, spots are searched with the help of their approximate displacements measured with low spatial resolution and large dynamic range. By the proposed method, a wavefront can be correctly measured even if the spot is beyond the detection area. The adaptive spot search method is realized by using the special microlens array that generates both spots and discriminable patterns. The proposed method enables expanding the dynamic range of an SHWFS with a single shot and short processing time. The performance of the proposed method is compared with that of a conventional SHWFS by optical experiments. Furthermore, the dynamic range of the proposed method is quantitatively evaluated by numerical simulations.

  18. Is introducing rapid culture into the diagnostic algorithm of smear-negative tuberculosis cost-effective?

    PubMed

    Yakhelef, N; Audibert, M; Varaine, F; Chakaya, J; Sitienei, J; Huerga, H; Bonnet, M

    2014-05-01

    In 2007, the World Health Organization recommended introducing rapid Mycobacterium tuberculosis culture into the diagnostic algorithm of smear-negative pulmonary tuberculosis (TB). To assess the cost-effectiveness of introducing a rapid non-commercial culture method (thin-layer agar), together with Löwenstein-Jensen culture to diagnose smear-negative TB at a district hospital in Kenya. Outcomes (number of true TB cases treated) were obtained from a prospective study evaluating the effectiveness of a clinical and radiological algorithm (conventional) against the alternative algorithm (conventional plus M. tuberculosis culture) in 380 smear-negative TB suspects. The costs of implementing each algorithm were calculated using a 'micro-costing' or 'ingredient-based' method. We then compared the cost and effectiveness of conventional vs. culture-based algorithms and estimated the incremental cost-effectiveness ratio. The costs of conventional and culture-based algorithms per smear-negative TB suspect were respectively €39.5 and €144. The costs per confirmed and treated TB case were respectively €452 and €913. The culture-based algorithm led to diagnosis and treatment of 27 more cases for an additional cost of €1477 per case. Despite the increase in patients started on treatment thanks to culture, the relatively high cost of a culture-based algorithm will make it difficult for resource-limited countries to afford.

  19. Use of multispectral Ikonos imagery for discriminating between conventional and conservation agricultural tillage practices

    USGS Publications Warehouse

    Vina, Andres; Peters, Albert J.; Ji, Lei

    2003-01-01

    There is a global concern about the increase in atmospheric concentrations of greenhouse gases. One method being discussed to encourage greenhouse gas mitigation efforts is based on a trading system whereby carbon emitters can buy effective mitigation efforts from farmers implementing conservation tillage practices. These practices sequester carbon from the atmosphere, and such a trading system would require a low-cost and accurate method of verification. Remote sensing technology can offer such a verification technique. This paper is focused on the use of standard image processing procedures applied to a multispectral Ikonos image, to determine whether it is possible to validate that farmers have complied with agreements to implement conservation tillage practices. A principal component analysis (PCA) was performed in order to isolate image variance in cropped fields. Analyses of variance (ANOVA) statistical procedures were used to evaluate the capability of each Ikonos band and each principal component to discriminate between conventional and conservation tillage practices. A logistic regression model was implemented on the principal component most effective in discriminating between conventional and conservation tillage, in order to produce a map of the probability of conventional tillage. The Ikonos imagery, in combination with ground-reference information, proved to be a useful tool for verification of conservation tillage practices.

  20. Analysis of an arched outer-race ball bearing considering centrifugal forces.

    NASA Technical Reports Server (NTRS)

    Hamrock, B. J.; Anderson, W. J.

    1972-01-01

    Thrust-load analysis of a 150-mm angular contact ball bearing, taking into account centrifugal forces but omitting gyroscopics, elastohydrodynamics, and thermal effects. A Newton-Raphson method of iteration is used to evaluate the radial and axial projection of the distance between the ball center and the outer raceway groove curvature center. Fatigue life of the bearing is evaluated. Results for life, contact loads, and angles are given for a conventional bearing and two arched bearings.

  1. A Balanced Scorecard-Based Model for Evaluating E-Learning and Conventional Pedagogical Activities in Nursing

    ERIC Educational Resources Information Center

    Hovelja, Tomaž; Vavpotic, Damjan; Žvanut, Boštjan

    2016-01-01

    The evaluation of e-learning and conventional pedagogical activities in nursing programmes has focused either on a single pedagogical activity or the entire curriculum, and only on students' or teachers' perspective. The goal of this study was to design and test a novel approach for evaluation of e-learning and conventional pedagogical activities…

  2. On-Demand Calibration and Evaluation for Electromagnetically Tracked Laparoscope in Augmented Reality Visualization

    PubMed Central

    Liu, Xinyang; Plishker, William; Zaki, George; Kang, Sukryool; Kane, Timothy D.; Shekhar, Raj

    2017-01-01

    Purpose Common camera calibration methods employed in current laparoscopic augmented reality systems require the acquisition of multiple images of an entire checkerboard pattern from various poses. This lengthy procedure prevents performing laparoscope calibration in the operating room (OR). The purpose of this work was to develop a fast calibration method for electromagnetically (EM) tracked laparoscopes, such that calibration can be performed in the OR on demand. Methods We designed a mechanical tracking mount to uniquely and snugly position an EM sensor to an appropriate location on a conventional laparoscope. A tool named fCalib was developed to calibrate intrinsic camera parameters, distortion coefficients, and extrinsic parameters (transformation between the scope lens coordinate system and the EM sensor coordinate system) using a single image that shows an arbitrary portion of a special target pattern. For quick evaluation of calibration result in the OR, we integrated a tube phantom with fCalib and overlaid a virtual representation of the tube on the live video scene. Results We compared spatial target registration error between the common OpenCV method and the fCalib method in a laboratory setting. In addition, we compared the calibration re-projection error between the EM tracking-based fCalib and the optical tracking-based fCalib in a clinical setting. Our results suggested that the proposed method is comparable to the OpenCV method. However, changing the environment, e.g., inserting or removing surgical tools, would affect re-projection accuracy for the EM tracking-based approach. Computational time of the fCalib method averaged 14.0 s (range 3.5 s – 22.7 s). Conclusions We developed and validated a prototype for fast calibration and evaluation of EM tracked conventional (forward viewing) laparoscopes. The calibration method achieved acceptable accuracy and was relatively fast and easy to be performed in the OR on demand. PMID:27250853

  3. Biointervention makes leather processing greener: an integrated cleansing and tanning system.

    PubMed

    Thanikaivelan, Palanisamy; Rao, Jonnalagadda Raghava; Nair, Balachandran Unni; Ramasami, Thirumalachari

    2003-06-01

    The do-undo methods adopted in conventional leather processing generate huge amounts of pollutants. In other words, conventional methods employed in leather processing subject the skin/hide to wide variations in pH. Pretanning and tanning processes alone contribute more than 90% of the total pollution from leather processing. Included in this is a great deal of solid wastes such as lime and chrome sludge. In the approach described here, the hair and flesh removal as well as fiber opening have been achieved using biocatalysts at pH 8.0 for cow hides. This was followed by a pickle-free chrome tanning, which does not require a basification step. Hence, this tanning technique involves primarily three steps, namely, dehairing, fiber opening, and tanning. It has been found that the extent of hair removal, opening up of fiber bundles, and penetration and distribution of chromium are comparable to that produced by traditional methods. This has been substantiated through scanning electron microscopic, stratigraphic chrome distribution analysis, and softness measurements. Performance of the leathers is shown to be on par with conventionally processed leathers through physical and hand evaluation. Importantly, softness of the leathers is numerically proven to be comparable with that of control. The process also demonstrates reduction in chemical oxygen demand load by 80%, total solids load by 85%, and chromium load by 80% as compared to the conventional process, thereby leading toward zero discharge. The input-output audit shows that the biocatalytic three-step tanning process employs a very low amount of chemicals, thereby reducing the discharge by 90% as compared to the conventional multistep processing. Furthermore, it is also demonstrated that the process is technoeconomically viable.

  4. Comparison of the CoaguChek XS handheld coagulation analyzer and conventional laboratory methods measuring international normalised ratio (INR) values during the time to therapeutic range after mechanical valve surgery.

    PubMed

    Bardakci, Hasmet; Altıntaş, Garip; Çiçek, Omer Faruk; Kervan, Umit; Yilmaz, Sevinc; Kaplan, Sadi; Birincioglu, Cemal Levent

    2013-05-01

    To compare the international normalised ratio (INR) value of patients evaluated using the CoaguChek XS versus conventional laboratory methods, in the period after open-heart surgery for mechanical valve replacement until a therapeutic range is achieved using vitamin K antagonists (VKA) together with low molecular weight heparin (LMWH). One hundred and five patients undergoing open-heart surgery for mechanical valve replacement were enrolled. Blood samples were collected from patients before surgery, and on the second and fifth postoperative days, simultaneously for both the point of care device and conventional laboratory techniques. Patients were administered VKA together with LMWH at therapeutic doses (enoxaparin 100 IU/kg twice daily) subcutaneously, until an effective range was achieved on approximately the fifth day after surgery. The mean INR values using the CoaguChek XS preoperatively and on the second and fifth days postoperatively were 1.20 (SD ± 0.09), 1.82 (SD ± 0.45), and 2.55 (SD ± 0.55), respectively. Corresponding results obtained using conventional laboratory techniques were 1.18 (SD ± 0.1), 1.81 (SD ± 0.43), and 2.51 (SD ± 0.58). The correlation coefficient was r = 0.77 preoperatively, r = 0.981 on postoperative day 2, and r = 0.983 on postoperative day 5. Results using the CoaguChek XS Handheld Coagulation Analyzer correlated strongly with conventional laboratory methods, in the bridging period between open-heart surgery for mechanical valve replacement and the achievement of a therapeutic range on warfarin and LMWH. © 2013 Wiley Periodicals, Inc.

  5. An efficient impedance method for induced field evaluation based on a stabilized Bi-conjugate gradient algorithm.

    PubMed

    Wang, Hua; Liu, Feng; Xia, Ling; Crozier, Stuart

    2008-11-21

    This paper presents a stabilized Bi-conjugate gradient algorithm (BiCGstab) that can significantly improve the performance of the impedance method, which has been widely applied to model low-frequency field induction phenomena in voxel phantoms. The improved impedance method offers remarkable computational advantages in terms of convergence performance and memory consumption over the conventional, successive over-relaxation (SOR)-based algorithm. The scheme has been validated against other numerical/analytical solutions on a lossy, multilayered sphere phantom excited by an ideal coil loop. To demonstrate the computational performance and application capability of the developed algorithm, the induced fields inside a human phantom due to a low-frequency hyperthermia device is evaluated. The simulation results show the numerical accuracy and superior performance of the method.

  6. A NEW LOG EVALUATION METHOD TO APPRAISE MESAVERDE RE-COMPLETION OPPORTUNITIES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Albert Greer

    2003-09-11

    Artificial intelligence tools, fuzzy logic and neural networks were used to evaluate the potential of the behind pipe Mesaverde formation in BMG's Mancos formation wells. A fractal geostatistical mapping algorithm was also used to predict Mesaverde production. Additionally, a conventional geological study was conducted. To date one Mesaverde completion has been performed. The Janet No.3 Mesaverde completion was non-economic. Both the AI method and the geostatistical methods predicted the failure of the Janet No.3. The Gavilan No.1 in the Mesaverde was completed during the course of the study and was an extremely good well. This well was not included inmore » the statistical dataset. The AI method predicted very good production while the fractal map predicted a poor producer.« less

  7. Evaluation of a HDR image sensor with logarithmic response for mobile video-based applications

    NASA Astrophysics Data System (ADS)

    Tektonidis, Marco; Pietrzak, Mateusz; Monnin, David

    2017-10-01

    The performance of mobile video-based applications using conventional LDR (Low Dynamic Range) image sensors highly depends on the illumination conditions. As an alternative, HDR (High Dynamic Range) image sensors with logarithmic response are capable to acquire illumination-invariant HDR images in a single shot. We have implemented a complete image processing framework for a HDR sensor, including preprocessing methods (nonuniformity correction (NUC), cross-talk correction (CTC), and demosaicing) as well as tone mapping (TM). We have evaluated the HDR sensor for video-based applications w.r.t. the display of images and w.r.t. image analysis techniques. Regarding the display we have investigated the image intensity statistics over time, and regarding image analysis we assessed the number of feature correspondences between consecutive frames of temporal image sequences. For the evaluation we used HDR image data recorded from a vehicle on outdoor or combined outdoor/indoor itineraries, and we performed a comparison with corresponding conventional LDR image data.

  8. The Application of Stress-Relaxation Test to Life Assessment of T911/T22 Weld Metal

    NASA Astrophysics Data System (ADS)

    Cao, Tieshan; Zhao, Jie; Cheng, Congqian; Li, Huifang

    2016-03-01

    A dissimilar weld metal was obtained through submerged arc welding of a T911 steel to a T22 steel, and its creep property was explored by stress-relaxation test assisted by some conventional creep tests. The creep rate information of the stress-relaxation test was compared to the minimum and the average creep rates of the conventional creep test. Log-log graph showed that the creep rate of the stress-relaxation test was in a linear relationship with the minimum creep rate of the conventional creep test. Thus, the creep rate of stress-relaxation test could be used in the Monkman-Grant relation to calculate the rupture life. The creep rate of the stress-relaxation test was similar to the average creep rate, and thereby the rupture life could be evaluated by a method of "time to rupture strain." The results also showed that rupture life which was assessed by the Monkman-Grant relation was more accurate than that obtained through the method of "time to rupture strain."

  9. Conventional and accelerated-solvent extractions of green tea (camellia sinensis) for metabolomics-based chemometrics.

    PubMed

    Kellogg, Joshua J; Wallace, Emily D; Graf, Tyler N; Oberlies, Nicholas H; Cech, Nadja B

    2017-10-25

    Metabolomics has emerged as an important analytical technique for multiple applications. The value of information obtained from metabolomics analysis depends on the degree to which the entire metabolome is present and the reliability of sample treatment to ensure reproducibility across the study. The purpose of this study was to compare methods of preparing complex botanical extract samples prior to metabolomics profiling. Two extraction methodologies, accelerated solvent extraction and a conventional solvent maceration, were compared using commercial green tea [Camellia sinensis (L.) Kuntze (Theaceae)] products as a test case. The accelerated solvent protocol was first evaluated to ascertain critical factors influencing extraction using a D-optimal experimental design study. The accelerated solvent and conventional extraction methods yielded similar metabolite profiles for the green tea samples studied. The accelerated solvent extraction yielded higher total amounts of extracted catechins, was more reproducible, and required less active bench time to prepare the samples. This study demonstrates the effectiveness of accelerated solvent as an efficient methodology for metabolomics studies. Copyright © 2017. Published by Elsevier B.V.

  10. Somatostatin receptor immunohistochemistry in neuroendocrine tumors: comparison between manual and automated evaluation

    PubMed Central

    Daniel, Kaemmerer; Maria, Athelogou; Amelie, Lupp; Isabell, Lenhardt; Stefan, Schulz; Luisa, Peter; Merten, Hommann; Vikas, Prasad; Gerd, Binnig; Paul, Baum Richard

    2014-01-01

    Background: Manual evaluation of somatostatin receptor (SSTR) immunohistochemistry (IHC) is a time-consuming and cost-intensive procedure. Aim of the study was to compare manual evaluation of SSTR subtype IHC to an automated software-based analysis, and to in-vivo imaging by SSTR-based PET/CT. Methods: We examined 25 gastroenteropancreatic neuroendocrine tumor (GEP-NET) patients and correlated their in-vivo SSTR-PET/CT data (determined by the standardized uptake values SUVmax,-mean) with the corresponding ex-vivo IHC data of SSTR subtype (1, 2A, 4, 5) expression. Exactly the same lesions were imaged by PET/CT, resected and analyzed by IHC in each patient. After manual evaluation, the IHC slides were digitized and automatically evaluated for SSTR expression by Definiens XD software. A virtual IHC score “BB1” was created for comparing the manual and automated analysis of SSTR expression. Results: BB1 showed a significant correlation with the corresponding conventionally determined Her2/neu score of the SSTR-subtypes 2A (rs: 0.57), 4 (rs: 0.44) and 5 (rs: 0.43). BB1 of SSTR2A also significantly correlated with the SUVmax (rs: 0.41) and the SUVmean (rs: 0.50). Likewise, a significant correlation was seen between the conventionally evaluated SSTR2A status and the SUVmax (rs: 0.42) and SUVmean (rs: 0.62).Conclusion: Our data demonstrate that the evaluation of the SSTR status by automated analysis (BB1 score), using digitized histopathology slides (“virtual microscopy”), corresponds well with the SSTR2A, 4 and 5 expression as determined by conventional manual histopathology. The BB1 score also exhibited a significant association to the SSTR-PET/CT data in accordance with the high affinity profile of the SSTR analogues used for imaging. PMID:25197368

  11. Usability evaluation of intradermal adapters (IDA).

    PubMed

    Tsals, Izrail

    2017-03-27

    Intradermal adapter device technology minimizes the complexity of the Mantoux technique, thereby providing predictable, reproducible intradermal (ID) injections and removing the concerns regarding the ease and reliability of Mantoux technique when using conventional needle and syringe. The technology employs a simple device with geometry designed to gently deform the skin surface and the subcutaneous tissue, providing the ideal angle and depth of needle insertion for consistently successful intradermal injections. The results of this development were presented at the First, Second and Third Skin Vaccination Summits in 2011, 2013 and 2015 respectively [1,2,3]. The current publication addresses the performance of intradermal adapters (IDA) evaluated in three preclinical studies. The evaluations were based on the assessment of bleb formation in a skin model, an accepted indicator of ID injection success. All evaluated devices share the same proprietary dermal interface technology. Devices instituting this design are easy to use, require minimal training, and employ conventionally molded parts and cannula. These studies evaluated IDAs of initial design integral with luer lock needles, IDAs for use with conventional syringes, and intradermal adapters for use with auto disable syringes (ADID adapters). The evaluated ID adapters were intended to consistently place the lancet of the needle at a depth of 0.75mm from the skin's surface. This placement depth addresses the variation in the skin thickness at immunization sites for the majority of patients independent of many other variables. Most participants preferred the intradermal adapter method over the traditional Mantoux and identified a need for the adapter at their workplace. Evaluation of IDAs by registered nurses indicated these devices increase success of bleb formation. The use of IDA increased the success of forming blebs by about 30%. Nurses felt the injections were much easier to perform, in particular by novices. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Comparison of the lysis centrifugation method with the conventional blood culture method in cases of sepsis in a tertiary care hospital.

    PubMed

    Parikh, Harshal R; De, Anuradha S; Baveja, Sujata M

    2012-07-01

    Physicians and microbiologists have long recognized that the presence of living microorganisms in the blood of a patient carries with it considerable morbidity and mortality. Hence, blood cultures have become critically important and frequently performed test in clinical microbiology laboratories for diagnosis of sepsis. To compare the conventional blood culture method with the lysis centrifugation method in cases of sepsis. Two hundred nonduplicate blood cultures from cases of sepsis were analyzed using two blood culture methods concurrently for recovery of bacteria from patients diagnosed clinically with sepsis - the conventional blood culture method using trypticase soy broth and the lysis centrifugation method using saponin by centrifuging at 3000 g for 30 minutes. Overall bacteria recovered from 200 blood cultures were 17.5%. The conventional blood culture method had a higher yield of organisms, especially Gram positive cocci. The lysis centrifugation method was comparable with the former method with respect to Gram negative bacilli. The sensitivity of lysis centrifugation method in comparison to conventional blood culture method was 49.75% in this study, specificity was 98.21% and diagnostic accuracy was 89.5%. In almost every instance, the time required for detection of the growth was earlier by lysis centrifugation method, which was statistically significant. Contamination by lysis centrifugation was minimal, while that by conventional method was high. Time to growth by the lysis centrifugation method was highly significant (P value 0.000) as compared to time to growth by the conventional blood culture method. For the diagnosis of sepsis, combination of the lysis centrifugation method and the conventional blood culture method with trypticase soy broth or biphasic media is advocable, in order to achieve faster recovery and a better yield of microorganisms.

  13. Evaluation of partial 16S ribosomal DNA sequencing for identification of nocardia species by using the MicroSeq 500 system with an expanded database.

    PubMed

    Cloud, Joann L; Conville, Patricia S; Croft, Ann; Harmsen, Dag; Witebsky, Frank G; Carroll, Karen C

    2004-02-01

    Identification of clinically significant nocardiae to the species level is important in patient diagnosis and treatment. A study was performed to evaluate Nocardia species identification obtained by partial 16S ribosomal DNA (rDNA) sequencing by the MicroSeq 500 system with an expanded database. The expanded portion of the database was developed from partial 5' 16S rDNA sequences derived from 28 reference strains (from the American Type Culture Collection and the Japanese Collection of Microorganisms). The expanded MicroSeq 500 system was compared to (i). conventional identification obtained from a combination of growth characteristics with biochemical and drug susceptibility tests; (ii). molecular techniques involving restriction enzyme analysis (REA) of portions of the 16S rRNA and 65-kDa heat shock protein genes; and (iii). when necessary, sequencing of a 999-bp fragment of the 16S rRNA gene. An unknown isolate was identified as a particular species if the sequence obtained by partial 16S rDNA sequencing by the expanded MicroSeq 500 system was 99.0% similar to that of the reference strain. Ninety-four nocardiae representing 10 separate species were isolated from patient specimens and examined by using the three different methods. Sequencing of partial 16S rDNA by the expanded MicroSeq 500 system resulted in only 72% agreement with conventional methods for species identification and 90% agreement with the alternative molecular methods. Molecular methods for identification of Nocardia species provide more accurate and rapid results than the conventional methods using biochemical and susceptibility testing. With an expanded database, the MicroSeq 500 system for partial 16S rDNA was able to correctly identify the human pathogens N. brasiliensis, N. cyriacigeorgica, N. farcinica, N. nova, N. otitidiscaviarum, and N. veterana.

  14. "Tie over ring" sutureless compression based gastrointestinal anastomotic method: experimental rat model.

    PubMed

    Hiradfar, Mehran; Shojaeian, Reza; Zabolinejad, Nona; Gharavifard, Mohammad; Sabzevari, Alireza; Joodi, Marjan; Yal, Nazila; Saeedi Sharifabad, Parisa; Hajian, Sara; Nazarzadeh, Reza; Lotfinejad, Nasim

    2014-03-01

    Giving the ever-rising trend of pediatric minimally invasive surgery besides early neonatal surgical interventions, intestinal anastomosis turns out to be a time consuming stage due to several anatomical as well as technical difficulties. A perfect bowel anastomosis method should be easy, rapid, safe and reliable in creation of bowel continuity with minimal tissue damage. In this light, sutureless anastomotic methods have been introduced, using compression based anastomosis with biofragmentable rings or powerful magnets. Accordingly, this experimental animal model study has evaluated the result of an easy, rapid intestinal sutureless anastomotic technique via simple tying over an intraluminal ring, in comparison with conventional handsewn bowel anastomosis. Thirty Wistar-Albino male rats were enrolled and small bowel was transected via a midline laparotomy. A grooved plastic ring was inserted into the ileal lumen and both intestinal cutting ends were fixed over the ring with a simple tie in the first group. On the other hand, enteroenterostomy was performed by the conventional method of handsewn anastomosis in the second group. After 14 days, rats were sacrificed to evaluate for intraperitoneal adhesion and abscess formation in addition to other evidences of anastomotic leakage. Furthermore, the anastomotic site integrity, tensile strength and healing stage were assessed microscopically. The mean operative time and intraoperative bleeding in the tie over ring group were significantly less than those in the handsewn anastomosis group. Anastomotic stricture was more common in the conventional anastomosis group while the anastomotic tensile strength was significantly higher in the tie over ring group. Histopathological healing parameters and final healing score were almost similar in both groups but mean inflammatory cell infiltration in handsewn anastomosis was significantly higher. "Tie over ring" is a simple method of anastomosis that is feasible, fast, safe and functionally effective for bowel reconstruction in animal models that could be reconsidered in human bowel anastomosis. © 2014.

  15. SU-E-T-293: Simplifying Assumption for Determining Sc and Sp

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    King, R; Cheung, A; Anderson, R

    Purpose: Scp(mlc,jaw) is a two-dimensional function of collimator field size and effective field size. Conventionally, Scp(mlc,jaw) is treated as separable into components Sc(jaw) and Sp(mlc). Scp(mlc=jaw) is measured in phantom and Sc(jaw) is measured in air with Sp=Scp/Sc. Ideally, Sc and Sp would be able to predict measured values of Scp(mlc,jaw) for all combinations of mlc and jaw. However, ideal Sc and Sp functions do not exist and a measured two-dimensional Scp dataset cannot be decomposed into a unique pair of one-dimensional functions.If the output functions Sc(jaw) and Sp(mlc) were equal to each other and thus each equal to Scp(mlc=jaw){supmore » 0.5}, this condition would lead to a simpler measurement process by eliminating the need for in-air measurements. Without the distorting effect of the buildup-cap, small-field measurement would be limited only by the dimensions of the detector and would thus be improved by this simplification of the output functions. The goal of the present study is to evaluate an assumption that Sc=Sp. Methods: For a 6 MV x-ray beam, Sc and Sp were determined both by the conventional method and as Scp(mlc=jaw){sup 0.5}. Square field benchmark values of Scp(mlc,jaw) were then measured across the range from 2×2 to 29×29. Both Sc and Sp functions were then evaluated as to their ability to predict these measurements. Results: Both methods produced qualitatively similar results with <4% error for all cases and >3% error in 1 case. The conventional method produced 2 cases with >2% error, while the squareroot method produced only 1 such case. Conclusion: Though it would need to be validated for any specific beam to which it might be applied, under the conditions studied, the simplifying assumption that Sc = Sp is justified.« less

  16. Fuzzy-C-Means Clustering Based Segmentation and CNN-Classification for Accurate Segmentation of Lung Nodules

    PubMed

    K, Jalal Deen; R, Ganesan; A, Merline

    2017-07-27

    Objective: Accurate segmentation of abnormal and healthy lungs is very crucial for a steadfast computer-aided disease diagnostics. Methods: For this purpose a stack of chest CT scans are processed. In this paper, novel methods are proposed for segmentation of the multimodal grayscale lung CT scan. In the conventional methods using Markov–Gibbs Random Field (MGRF) model the required regions of interest (ROI) are identified. Result: The results of proposed FCM and CNN based process are compared with the results obtained from the conventional method using MGRF model. The results illustrate that the proposed method can able to segment the various kinds of complex multimodal medical images precisely. Conclusion: However, in this paper, to obtain an exact boundary of the regions, every empirical dispersion of the image is computed by Fuzzy C-Means Clustering segmentation. A classification process based on the Convolutional Neural Network (CNN) classifier is accomplished to distinguish the normal tissue and the abnormal tissue. The experimental evaluation is done using the Interstitial Lung Disease (ILD) database. Creative Commons Attribution License

  17. A new axial smoothing method based on elastic mapping

    NASA Astrophysics Data System (ADS)

    Yang, J.; Huang, S. C.; Lin, K. P.; Czernin, J.; Wolfenden, P.; Dahlbom, M.; Hoh, C. K.; Phelps, M. E.

    1996-12-01

    New positron emission tomography (PET) scanners have higher axial and in-plane spatial resolutions but at the expense of reduced per plane sensitivity, which prevents the higher resolution from being fully realized. Normally, Gaussian-weighted interplane axial smoothing is used to reduce noise. In this study, the authors developed a new algorithm that first elastically maps adjacent planes, and then the mapped images are smoothed axially to reduce the image noise level. Compared to those obtained by the conventional axial-directional smoothing method, the images by the new method have improved signal-to-noise ratio. To quantify the signal-to-noise improvement, both simulated and real cardiac PET images were studied. Various Hanning reconstruction filters with cutoff frequency=0.5, 0.7, 1.0/spl times/Nyquist frequency and Ramp filter were tested on simulated images. Effective in-plane resolution was measured by the effective global Gaussian resolution (EGGR) and noise reduction was evaluated by the cross-correlation coefficient. Results showed that the new method was robust to various noise levels and indicated larger noise reduction or better image feature preservation (i.e., smaller EGGR) than by the conventional method.

  18. Fuzzy-C-Means Clustering Based Segmentation and CNN-Classification for Accurate Segmentation of Lung Nodules

    PubMed Central

    K, Jalal Deen; R, Ganesan; A, Merline

    2017-01-01

    Objective: Accurate segmentation of abnormal and healthy lungs is very crucial for a steadfast computer-aided disease diagnostics. Methods: For this purpose a stack of chest CT scans are processed. In this paper, novel methods are proposed for segmentation of the multimodal grayscale lung CT scan. In the conventional methods using Markov–Gibbs Random Field (MGRF) model the required regions of interest (ROI) are identified. Result: The results of proposed FCM and CNN based process are compared with the results obtained from the conventional method using MGRF model. The results illustrate that the proposed method can able to segment the various kinds of complex multimodal medical images precisely. Conclusion: However, in this paper, to obtain an exact boundary of the regions, every empirical dispersion of the image is computed by Fuzzy C-Means Clustering segmentation. A classification process based on the Convolutional Neural Network (CNN) classifier is accomplished to distinguish the normal tissue and the abnormal tissue. The experimental evaluation is done using the Interstitial Lung Disease (ILD) database. PMID:28749127

  19. Simple adaptive sparse representation based classification schemes for EEG based brain-computer interface applications.

    PubMed

    Shin, Younghak; Lee, Seungchan; Ahn, Minkyu; Cho, Hohyun; Jun, Sung Chan; Lee, Heung-No

    2015-11-01

    One of the main problems related to electroencephalogram (EEG) based brain-computer interface (BCI) systems is the non-stationarity of the underlying EEG signals. This results in the deterioration of the classification performance during experimental sessions. Therefore, adaptive classification techniques are required for EEG based BCI applications. In this paper, we propose simple adaptive sparse representation based classification (SRC) schemes. Supervised and unsupervised dictionary update techniques for new test data and a dictionary modification method by using the incoherence measure of the training data are investigated. The proposed methods are very simple and additional computation for the re-training of the classifier is not needed. The proposed adaptive SRC schemes are evaluated using two BCI experimental datasets. The proposed methods are assessed by comparing classification results with the conventional SRC and other adaptive classification methods. On the basis of the results, we find that the proposed adaptive schemes show relatively improved classification accuracy as compared to conventional methods without requiring additional computation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. FDTD and transfer matrix methods for evaluating the performance of photonic crystal based microcavities for exciton-polaritons

    NASA Astrophysics Data System (ADS)

    Liu, Yi-Cheng; Byrnes, Tim

    2016-11-01

    We investigate alternative microcavity structures for exciton-polaritons consisting of photonic crystals instead of distributed Bragg reflectors. Finite-difference time-domain simulations and scattering transfer matrix methods are used to evaluate the cavity performance. The results are compared with conventional distributed Bragg reflectors. We find that in terms of the photon lifetime, the photonic crystal based microcavities are competitive, with typical lifetimes in the region of ∼20 ps being achieved. The photonic crystal microcavities have the advantage that they are compact and are frequency adjustable, showing that they are viable to investigate exciton-polariton condensation physics.

  1. Improvement of core drill methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gatz, J.L.

    1975-07-01

    This report documents results of a program to evaluate effectiveness of more or less conventional subsurface samplers in obtaining representative and undisturbed samples of noncohesive alluvial materials containing large quantities of gravels and cobbles. This is the first phase of a research program to improve core drill methods. Samplers evaluated consisted of the Lawrence Livermore Laboratory membrane sampler, 4-in. Denison sampler, 6-in. Dension sampler, 5-in. Modified Denison sampler, and 3-in. thinwall drive tube. Small representative samples were obtained with the Dension samplers; no undisturbed samples were obtained. The field work was accomplished in the Rhodes Canyon area, White Sands Misslemore » Range, New Mexico.« less

  2. A work study of the CAD/CAM method and conventional manual method in the fabrication of spinal orthoses for patients with adolescent idiopathic scoliosis.

    PubMed

    Wong, M S; Cheng, J C Y; Wong, M W; So, S F

    2005-04-01

    A study was conducted to compare the CAD/CAM method with the conventional manual method in fabrication of spinal orthoses for patients with adolescent idiopathic scoliosis. Ten subjects were recruited for this study. Efficiency analyses of the two methods were performed from cast filling/ digitization process to completion of cast/image rectification. The dimensional changes of the casts/ models rectified by the two cast rectification methods were also investigated. The results demonstrated that the CAD/CAM method was faster than the conventional manual method in the studied processes. The mean rectification time of the CAD/CAM method was shorter than that of the conventional manual method by 108.3 min (63.5%). This indicated that the CAD/CAM method took about 1/3 of the time of the conventional manual to finish cast rectification. In the comparison of cast/image dimensional differences between the conventional manual method and the CAD/CAM method, five major dimensions in each of the five rectified regions namely the axilla, thoracic, lumbar, abdominal and pelvic regions were involved. There were no significant dimensional differences (p < 0.05) in 19 out of the 25 studied dimensions. This study demonstrated that the CAD/CAM system could save the time in the rectification process and offer a relatively high resemblance in cast rectification as compared with the conventional manual method.

  3. Identification of Technological Parameters of Ni-Alloys When Machining by Monolithic Ceramic Milling Tool

    NASA Astrophysics Data System (ADS)

    Czán, Andrej; Kubala, Ondrej; Danis, Igor; Czánová, Tatiana; Holubják, Jozef; Mikloš, Matej

    2017-12-01

    The ever-increasing production and the usage of hard-to-machine progressive materials are the main cause of continual finding of new ways and methods of machining. One of these ways is the ceramic milling tool, which combines the pros of conventional ceramic cutting materials and pros of conventional coating steel-based insert. These properties allow to improve cutting conditions and so increase the productivity with preserved quality known from conventional tools usage. In this paper, there is made the identification of properties and possibilities of this tool when machining of hard-to-machine materials such as nickel alloys using in airplanes engines. This article is focused on the analysis and evaluation ordinary technological parameters and surface quality, mainly roughness of surface and quality of machined surface and tool wearing.

  4. Design of piezoelectric probe for measurement of longitudinal and shear components of elastic wave

    NASA Astrophysics Data System (ADS)

    Aoyanagi, Masafumi; Wakatsuki, Naoto; Mizutani, Koichi; Ebihara, Tadashi

    2017-07-01

    We focus on ultrasonic probes for nondestructive tests and evaluation. Transient characteristics of probes are important for nondestructive tests such as the pulse echo method. We previously reported the principle of measurement using a piezoelectric probe with triaxial sensitivities. In the results, it was calculated that the probe could transmit and receive particle displacement which contains normal and tangential components. It was confirmed that the probe had sensitivities in triaxial directions. However, its performance in terms of frequency and transient characteristics has not been evaluated. The purpose of this study is to design a probe by changing its shape to obtain better performance. The transient characteristics of probes in longitudinal and shear driving were evaluated by the inverse Fourier transformation of frequency responses of longitudinal and shear components, using the two-dimensional finite element method. As a result, the sensitivities at the dips of frequency characteristics increased when using our probe compared with those measured using conventional probes in longitudinal and shear driving. Hence, the performance in terms of the frequency response was improved by more than 3 dB under the conditions in this simulation. Also, the pulse width of impulse response was decreased by half compared with that of probes with conventional shapes.

  5. Improving Communication of Diagnostic Radiology Findings through Structured Reporting

    PubMed Central

    Panicek, David M.; Berk, Alexandra R.; Li, Yuelin; Hricak, Hedvig

    2011-01-01

    Purpose: To compare the content, clarity, and clinical usefulness of conventional (ie, free-form) and structured radiology reports of body computed tomographic (CT) scans, as evaluated by referring physicians, attending radiologists, and radiology fellows at a tertiary care cancer center. Materials and Methods: The institutional review board approved the study as a quality improvement initiative; no written consent was required. Three radiologists, three radiology fellows, three surgeons, and two medical oncologists evaluated 330 randomly selected conventional and structured radiology reports of body CT scans. For nonradiologists, reports were randomly selected from patients with diagnoses relevant to the physician’s area of specialization. Each physician read 15 reports in each format and rated both the content and clarity of each report from 1 (very dissatisfied or very confusing) to 10 (very satisfied or very clear). By using a previously published radiology report grading scale, physicians graded each report’s effectiveness in advancing the patient’s position on the clinical spectrum. Mixed-effects models were used to test differences between report types. Results: Mean content satisfaction ratings were 7.61 (95% confidence interval [CI]: 7.12, 8.16) for conventional reports and 8.33 (95% CI: 7.82, 8.86) for structured reports, and the difference was significant (P < .0001). Mean clarity satisfaction ratings were 7.45 (95% CI: 6.89, 8.02) for conventional reports and 8.25 (95% CI: 7.68, 8.82) for structured reports, and the difference was significant (P < .0001). Grade ratings did not differ significantly between conventional and structured reports. Conclusion: Referring clinicians and radiologists found that structured reports had better content and greater clarity than conventional reports. © RSNA, 2011 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101913/-/DC1 PMID:21518775

  6. Cost-utility analysis of the EVOLVO study on remote monitoring for heart failure patients with implantable defibrillators: randomized controlled trial.

    PubMed

    Zanaboni, Paolo; Landolina, Maurizio; Marzegalli, Maurizio; Lunati, Maurizio; Perego, Giovanni B; Guenzati, Giuseppe; Curnis, Antonio; Valsecchi, Sergio; Borghetti, Francesca; Borghi, Gabriella; Masella, Cristina

    2013-05-30

    Heart failure patients with implantable defibrillators place a significant burden on health care systems. Remote monitoring allows assessment of device function and heart failure parameters, and may represent a safe, effective, and cost-saving method compared to conventional in-office follow-up. We hypothesized that remote device monitoring represents a cost-effective approach. This paper summarizes the economic evaluation of the Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study, a multicenter clinical trial aimed at measuring the benefits of remote monitoring for heart failure patients with implantable defibrillators. Two hundred patients implanted with a wireless transmission-enabled implantable defibrillator were randomized to receive either remote monitoring or the conventional method of in-person evaluations. Patients were followed for 16 months with a protocol of scheduled in-office and remote follow-ups. The economic evaluation of the intervention was conducted from the perspectives of the health care system and the patient. A cost-utility analysis was performed to measure whether the intervention was cost-effective in terms of cost per quality-adjusted life year (QALY) gained. Overall, remote monitoring did not show significant annual cost savings for the health care system (€1962.78 versus €2130.01; P=.80). There was a significant reduction of the annual cost for the patients in the remote arm in comparison to the standard arm (€291.36 versus €381.34; P=.01). Cost-utility analysis was performed for 180 patients for whom QALYs were available. The patients in the remote arm gained 0.065 QALYs more than those in the standard arm over 16 months, with a cost savings of €888.10 per patient. Results from the cost-utility analysis of the EVOLVO study show that remote monitoring is a cost-effective and dominant solution. Remote management of heart failure patients with implantable defibrillators appears to be cost-effective compared to the conventional method of in-person evaluations. ClinicalTrials.gov NCT00873899; http://clinicaltrials.gov/show/NCT00873899 (Archived by WebCite at http://www.webcitation.org/6H0BOA29f).

  7. An Assessment of Nondestructive Evaluation Capability for Complex Additive Manufacturing Aerospace Components

    NASA Technical Reports Server (NTRS)

    Walker, James; Beshears, Ron; Lambert, Dennis; Tilson, William

    2016-01-01

    The primary focus of this work is to investigate some of the fundamental relationships between processing, mechanical testing, materials characterization, and NDE for additively manufactured (AM) components using the powder bed fusion direct melt laser sintered process. The goal is to understand the criticality of defects unique to the AM process and then how conventional nondestructive evaluation methods as well as some of the more non-traditional methods such as computed tomography, are effected by the AM material. Specific defects including cracking, porosity and partially/unfused powder will be addressed. Besides line-of-site NDE, as appropriate these inspection capabilities will be put into the context of complex AM geometries where hidden features obscure, or inhibit traditional NDE methods.

  8. Evaluation of the Effect of Different Laser Activated Bleaching Methods on Enamel Susceptibility to Caries; An In Vitro Mode.

    PubMed

    Ashnagar, Sajjad; Monzavi, Abbas; Abbasi, Mehdi; Aghajani, Mahdi; Chiniforush, Nasim

    2017-01-01

    Introduction: Today, bleaching is a routine noninvasive alternative for treatment of discolored teeth. The aim of this study was to determine whether conventional or laser activated bleaching predispose teeth to develop caries or not. Methods: Sixty human molars were mounted on acrylic cylinders and their Knoop microhardness (KHN) as well as DIAGNOdent (DD) values were recorded. They were divided into 4 experimental groups; G1) conventional bleaching with 40% hydrogen peroxide gel, G2) Diode laser assisted bleaching with same gel, G3) Nd:YAG laser assisted bleaching with the same gel, G4) control group. After bleaching, all samples were subjected to a three day pH cycling regimen and then, KHN and DD values were measured. Results: All groups had significant reduction in KHN values. It seems that there is no statistically meaningful difference between changes in enamel microhardness of the sample groups and all groups have changed in a similar amount. Reduction of DD scores were significant in Diode laser and conventional groups, however changes in Nd:YAG laser and control groups were not significant. Changes in DD values have followed a similar pattern among groups, except in G1- G4 and G2-G4 couples. Conventional and diode laser groups had a meaningful difference in reduction of DD values in comparison with the control group. Conclusion: It can be concluded that bleaching whether conventional or laser activated, does not make teeth vulnerable to develop carious lesions.

  9. Ictal and interictal electric source imaging in presurgical evaluation: a prospective study.

    PubMed

    Sharma, Praveen; Scherg, Michael; Pinborg, Lars H; Fabricius, Martin; Rubboli, Guido; Pedersen, Birthe; Leffers, Anne-Mette; Uldall, Peter; Jespersen, Bo; Brennum, Jannick; Mølby Henriksen, Otto; Beniczky, Sándor

    2018-05-11

    Accurate localization of the epileptic focus is essential for surgical treatment of patients with drug- resistant epilepsy. EEG source imaging (ESI) is increasingly used in presurgical evaluation. However, most previous studies analysed interictal discharges. Prospective studies comparing feasibility and accuracy of interictal (II) and ictal (IC) ESI are lacking. We prospectively analysed long-term video EEG recordings (LTM) of patients admitted for presurgical evaluation. We performed ESI of II and IC signals, using two methods: equivalent current dipole (ECD) and distributed source model (DSM). LTM recordings employed the standard 25-electrode array (including inferior temporal electrodes). An age-matched template head-model was used for source analysis. Results were compared with intracranial recordings (ICR), conventional neuroimaging methods (MRI, PET, SPECT) and outcome one year after surgery. Eighty-seven consecutive patients were analysed. ECD gave a significantly higher proportion of patients with localised focal abnormalities (94%) compared to MRI (70%), PET (66%) and SPECT (64%). Agreement between the ESI methods and ICR was moderate to substantial (k=0.56-0.79). Fifty-four patients were operated (47 for more than one year ago) and 62% of them became seizure-free. Localization accuracy of II-ESI was 51% for DSM and 57% for ECD; for IC-ESI this was 51% (DSM) and 62% (ECD). The differences between the ESI methods were not significant. Differences in localization accuracy between ESI and MRI (55%), PET (33%) and SPECT (40%) were not significant. II and IC ESI of LTM-data have high feasibility and their localisation accuracy is similar to the conventional neuroimaging methods. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  10. Investigation of nano lipid vesicles of methotrexate for anti-rheumatoid activity

    PubMed Central

    Prabhu, Prabhakara; Shetty, Rakshith; Koland, Marina; Vijayanarayana, K; Vijayalakshmi, KK; Nairy, M Harish; Nisha, GS

    2012-01-01

    Background The purpose of this study was to formulate and evaluate nano lipid vesicles of methotrexate (MTX) for its anti-rheumatoid activity. Methods In this study the principle of both active as well as passive targeting using MTX-loaded stealth liposomes as per the magic gun approach was followed. Stealth liposomes of MTX were prepared by thin-film hydration method using a PEGylated phospholipid-like DSPE-MPEG 2000. Similarly, conventional liposomes were prepared using phospholipids like DPPC and DSPC. Conventional liposomes were coated with a hydrophilic biocompatible polymer like chitosan. They were investigated for their physical properties and in vitro release profile. Further, in vivo screening of the formulations for their anti-rheumatoid efficacy was carried out in rats. Rheumatoid arthritis was induced in male Wistar-Lewis rats using complete Freund’s adjuvant (1 mg/mL Mycobacterium tuberculosis, heat killed in mineral oil). Results It was found that chitosan coating of the conventional liposomes increased the physical stability of the liposomal suspension as well as its entrapment efficiency. The size of the unsonicated lipid vesicles was found to be in the range of 8–10 μm, and the sonicated lipid vesicles in the range of 210–260 nm, with good polydispersity index. Further, chitosan-coated conventional liposomes and the PEGylated liposomes released the drug for a prolonged period of time, compared to the uncoated conventional liposomes. It was found that there was a significant reduction in edema volume in the rat group administered with the test stealth liposomal formulations and chitosan-coated conventional liposomes (PEGylated and chitosan-coated conventional) compared to that of the control and standard (administered with free MTX) group of rats. PEGylated liposomes showed almost equal efficacy as that of the chitosan-coated conventional liposomes. Conclusion Lipid nano vesicles of MTX can be administered by intravenous route, whereby the drug selectively reaches the target site with reduced toxicity to other organs. PMID:22275833

  11. Levonorgestrel-Releasing Intrauterine System versus Medical Therapy for Menorrhagia: A Systematic Review and Meta-Analysis

    PubMed Central

    Qiu, Jin; Cheng, Jiajing; Wang, Qingying; Hua, Jie

    2014-01-01

    Background The aim of this study was to compare the effects of the levonorgestrel-releasing intrauterine system (LNG-IUS) with conventional medical treatment in reducing heavy menstrual bleeding. Material/Methods Relevant studies were identified by a search of MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, and clinical trials registries (from inception to April 2014). Randomized controlled trials comparing the LNG-IUS with conventional medical treatment (mefenamic acid, tranexamic acid, norethindrone, medroxyprogesterone acetate injection, or combined oral contraceptive pills) in patients with menorrhagia were included. Results Eight randomized controlled trials that included 1170 women (LNG-IUS, n=562; conventional medical treatment, n=608) met inclusion criteria. The LNG-IUS was superior to conventional medical treatment in reducing menstrual blood loss (as measured by the alkaline hematin method or estimated by pictorial bleeding assessment chart scores). More women were satisfied with the LNG-IUS than with the use of conventional medical treatment (odds ratio [OR] 5.19, 95% confidence interval [CI] 2.73–9.86). Compared with conventional medical treatment, the LNG-IUS was associated with a lower rate of discontinuation (14.6% vs. 28.9%, OR 0.39, 95% CI 0.20–0.74) and fewer treatment failures (9.2% vs. 31.0%, OR 0.18, 95% CI 0.10–0.34). Furthermore, quality of life assessment favored LNG-IUS over conventional medical treatment, although use of various measurements limited our ability to pool the data for more powerful evidence. Serious adverse events were statistically comparable between treatments. Conclusions The LNG-IUS was the more effective first choice for management of menorrhagia compared with conventional medical treatment. Long-term, randomized trials are required to further investigate patient-based outcomes and evaluate the cost-effectiveness of the LNG-IUS and other medical treatments. PMID:25245843

  12. Evaluation of thermal cooling mechanisms for laser application to teeth.

    PubMed

    Miserendino, L J; Abt, E; Wigdor, H; Miserendino, C A

    1993-01-01

    Experimental cooling methods for the prevention of thermal damage to dental pulp during laser application to teeth were compared to conventional treatment in vitro. Pulp temperature measurements were made via electrical thermistors implanted within the pulp chambers of extracted human third molar teeth. Experimental treatments consisted of lasing without cooling, lasing with cooling, laser pulsing, and high-speed dental rotary drilling. Comparisons of pulp temperature elevation measurements for each group demonstrated that cooling by an air and water spray during lasing significantly reduced heat transfer to dental pulp. Laser exposures followed by an air and water spray resulted in pulp temperature changes comparable to conventional treatment by drilling. Cooling by an air water spray with evacuation appears to be an effective method for the prevention of thermal damage to vital teeth following laser exposure.

  13. Direct PCR - A rapid method for multiplexed detection of different serotypes of Salmonella in enriched pork meat samples.

    PubMed

    Chin, Wai Hoe; Sun, Yi; Høgberg, Jonas; Quyen, Than Linh; Engelsmann, Pia; Wolff, Anders; Bang, Dang Duong

    2017-04-01

    Salmonellosis, an infectious disease caused by Salmonella spp., is one of the most common foodborne diseases. Isolation and identification of Salmonella by conventional bacterial culture method is time consuming. In response to the demand for rapid on line or at site detection of pathogens, in this study, we developed a multiplex Direct PCR method for rapid detection of different Salmonella serotypes directly from pork meat samples without any DNA purification steps. An inhibitor-resistant Phusion Pfu DNA polymerase was used to overcome PCR inhibition. Four pairs of primers including a pair of newly designed primers targeting Salmonella spp. at subtype level were incorporated in the multiplex Direct PCR. To maximize the efficiency of the Direct PCR, the ratio between sample and dilution buffer was optimized. The sensitivity and specificity of the multiplex Direct PCR were tested using naturally contaminated pork meat samples for detecting and subtyping of Salmonella spp. Conventional bacterial culture methods were used as reference to evaluate the performance of the multiplex Direct PCR. Relative accuracy, sensitivity and specificity of 98.8%; 97.6% and 100%, respectively, were achieved by the method. Application of the multiplex Direct PCR to detect Salmonella in pork meat at slaughter reduces the time of detection from 5 to 6 days by conventional bacterial culture and serotyping methods to 14 h (including 12 h enrichment time). Furthermore, the method poses a possibility of miniaturization and integration into a point-of-need Lab-on-a-chip system for rapid online pathogen detection. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Comparison of Radiofrequency and Electrocautery With Conventional Scalpel Incisions.

    PubMed

    Hasar, Zafer Burak; Ozmeric, Nurdan; Ozdemir, Burcu; Gökmenoğlu, Ceren; Baris, Emre; Altan, Gökçen; Kahraman, Sevil

    2016-11-01

    The disadvantages of conventional scalpels, including insufficient control of bleeding, prompted us to search for new alternative methods such as electrosurgery and radiosurgery. In this study, the conventional scalpel was compared with radiosurgery and electrosurgery for wound healing with assessment of lateral heat production, inflammation, and instrument performance. Incisions were made in the palatal mucosa of 42 Wistar rats using a scalpel, electrocautery instrument, or radiofrequency instrument. Postoperative hemostasis, tissue coagulation, and tissue sticking were measured, and pain evaluation through weight loss was recorded. Gingival biopsy specimens from the surgical area were obtained at the time of surgery and 2, 4, 7, and 14 days postoperatively and were evaluated immunohistochemically for inducible nitric oxide synthase and heat shock protein 70. Kruskal-Wallis, 1-way analysis of variance, and Mann-Whitney U tests were used for statistical evaluation. The rats in the electrosurgery and radiosurgery groups had aggressively greater weight loss when compared with the scalpel group in the first 7 days. Hemostasis was better in the electrocautery group, tissue coagulation was greater in the radiofrequency group (P < .001), and tissue sticking was lesser in the scalpel group (P < .001) compared with the other groups. Inducible nitric oxide synthase expression and heat shock protein 70 expression were similar in all 3 groups. Electrosurgery performed better regarding hemostasis, whereas a scalpel was superior in terms of tissue sticking and tissue coagulation. Radiosurgery was superior regarding hemostasis when compared with a conventional scalpel, but it was not as successful as electrosurgery. Copyright © 2016. Published by Elsevier Inc.

  15. Impact of rearing conditions on the microbiological quality of raw retail poultry meat.

    PubMed

    Hardy, Bridgshe; Crilly, Nate; Pendleton, Sean; Andino, Ana; Wallis, Audra; Zhang, Nan; Hanning, Irene

    2013-08-01

    There is a gap in knowledge of microbiological quality in raw chicken products produced by nonconventional methods and no studies have reported the microbiological quality of turkeys produced under different rearing environments. Thus, the aim of this study was to compare the microbiological quality of conventionally and organically reared whole chicken and turkey carcasses purchased from 3 retail outlets in Knoxville, Tenn., U.S.A. A total of 100 raw broiler chickens organically (n = 50) and 50 raw turkey carcasses consisting of 3 brands reared either conventionally (n = 25) or organically (n = 25) were evaluated. The FDA BAM protocol for rinsing poultry carcasses was used to enumerate of aerobic bacteria, Campylobacter, and Staphylococcus spp., and for qualitative analysis of Salmonella. Organic chickens from one brand had the highest average counts of aerobic bacteria, Staphylococcus spp. and Campylobacter (4.8, 4.8, and 4.7 Log10 CFU/mL rinsate, respectively) while the other organic brand had the lowest average counts (3.4, 3.3, and 3.1, respectively) of all 4 brands evaluated. The organic turkeys had the highest average counts of these same bacteria (4, 3.9, and 3.8, respectively) compared to the 2 brands of conventional turkeys evaluated. Salmonella (5% prevalence) was isolated only from organic chickens and turkeys. From these data, it appears that the microbiological quality of the raw product was not dependent on rearing conditions and, thus, it cannot be assumed that organic raw poultry is safer than conventionally raised poultry in terms of microbiological quality. © 2013 Institute of Food Technologists®

  16. Knowledge-based reconstruction for measurement of right ventricular volumes on cardiovascular magnetic resonance images in a mixed population.

    PubMed

    Pieterman, Elise D; Budde, Ricardo P J; Robbers-Visser, Daniëlle; van Domburg, Ron T; Helbing, Willem A

    2017-09-01

    Follow-up of right ventricular performance is important for patients with congenital heart disease. Cardiac magnetic resonance imaging is optimal for this purpose. However, observer-dependency of manual analysis of right ventricular volumes limit its use. Knowledge-based reconstruction is a new semiautomatic analysis tool that uses a database including knowledge of right ventricular shape in various congenital heart diseases. We evaluated whether knowledge-based reconstruction is a good alternative for conventional analysis. To assess the inter- and intra-observer variability and agreement of knowledge-based versus conventional analysis of magnetic resonance right ventricular volumes, analysis was done by two observers in a mixed group of 22 patients with congenital heart disease affecting right ventricular loading conditions (dextro-transposition of the great arteries and right ventricle to pulmonary artery conduit) and a group of 17 healthy children. We used Bland-Altman analysis and coefficient of variation. Comparison between the conventional method and the knowledge-based method showed a systematically higher volume for the latter group. We found an overestimation for end-diastolic volume (bias -40 ± 24 mL, r = .956), end-systolic volume (bias -34 ± 24 mL, r = .943), stroke volume (bias -6 ± 17 mL, r = .735) and an underestimation of ejection fraction (bias 7 ± 7%, r = .671) by knowledge-based reconstruction. The intra-observer variability of knowledge-based reconstruction varied with a coefficient of variation of 9% for end-diastolic volume and 22% for stroke volume. The same trend was noted for inter-observer variability. A systematic difference (overestimation) was noted for right ventricular size as assessed with knowledge-based reconstruction compared with conventional methods for analysis. Observer variability for the new method was comparable to what has been reported for the right ventricle in children and congenital heart disease with conventional analysis. © 2017 Wiley Periodicals, Inc.

  17. Performance of statistical process control methods for regional surgical site infection surveillance: a 10-year multicentre pilot study.

    PubMed

    Baker, Arthur W; Haridy, Salah; Salem, Joseph; Ilieş, Iulian; Ergai, Awatef O; Samareh, Aven; Andrianas, Nicholas; Benneyan, James C; Sexton, Daniel J; Anderson, Deverick J

    2017-11-24

    Traditional strategies for surveillance of surgical site infections (SSI) have multiple limitations, including delayed and incomplete outbreak detection. Statistical process control (SPC) methods address these deficiencies by combining longitudinal analysis with graphical presentation of data. We performed a pilot study within a large network of community hospitals to evaluate performance of SPC methods for detecting SSI outbreaks. We applied conventional Shewhart and exponentially weighted moving average (EWMA) SPC charts to 10 previously investigated SSI outbreaks that occurred from 2003 to 2013. We compared the results of SPC surveillance to the results of traditional SSI surveillance methods. Then, we analysed the performance of modified SPC charts constructed with different outbreak detection rules, EWMA smoothing factors and baseline SSI rate calculations. Conventional Shewhart and EWMA SPC charts both detected 8 of the 10 SSI outbreaks analysed, in each case prior to the date of traditional detection. Among detected outbreaks, conventional Shewhart chart detection occurred a median of 12 months prior to outbreak onset and 22 months prior to traditional detection. Conventional EWMA chart detection occurred a median of 7 months prior to outbreak onset and 14 months prior to traditional detection. Modified Shewhart and EWMA charts additionally detected several outbreaks earlier than conventional SPC charts. Shewhart and SPC charts had low false-positive rates when used to analyse separate control hospital SSI data. Our findings illustrate the potential usefulness and feasibility of real-time SPC surveillance of SSI to rapidly identify outbreaks and improve patient safety. Further study is needed to optimise SPC chart selection and calculation, statistical outbreak detection rules and the process for reacting to signals of potential outbreaks. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Is it possible to reduce intra-hospital transport time for computed tomography evaluation in critically ill cases using the Easy Tube Arrange Device?

    PubMed

    Song, Kyung Hyeok; Cho, Sung Uk; Lee, Jin Woong; Cho, Yong Chul; Jeong, Won Joon; You, Yeon Ho; Ryu, Seung; Kim, Seung Whan; Yoo, In Sool; Joo, Ki Hyuk

    2018-03-01

    Patients are often transported within the hospital, especially in cases of critical illness for which computed tomography (CT) is performed. Since increased transport time increases the risks of complications, reducing transport time is important for patient safety. This study aimed to evaluate the ability of our newly invented device, the Easy Tube Arrange Device (ETAD), to reduce transport time for CT evaluation in cases of critical illness. This prospective randomized control study included 60 volunteers. Each participant arranged five or six intravenous fluid lines, monitoring lines (noninvasive blood pressure, electrocardiography, central venous pressure, arterial catheter), and therapeutic equipment (O2 supply device, Foley catheter) on a Resusci Anne mannequin. We measured transport time for the CT evaluation by using conventional and ETAD method. The median transport time for CT evaluation was 488.50 seconds (95% confidence interval [CI], 462.75 to 514.75) and, 503.50 seconds (95% CI, 489.50 to 526.75) with 5 and 6 fluid lines using the conventional method and 364.50 seconds (95% CI, 335.00 to 388.75), and 363.50 seconds (95% CI, 331.75 to 377.75) with ETAD (all P<0.001). The time differences were 131.50 (95% CI, 89.25 to 174.50) and 148.00 (95% CI, 116.00 to 177.75) (all P<0.001). The transport time for CT evaluation was reduced using the ETAD, which would be expected to reduce the complications that may occur during transport in cases of critical illness.

  19. Evaluation of 99mTc-MIBI in thyroid gland imaging for the diagnosis of amiodarone-induced thyrotoxicosis

    PubMed Central

    Zhang, Ruiguo

    2017-01-01

    Objective: Amiodarone-induced thyrotoxicosis (AIT) is caused by amiodarone as a side effect of cardiovascular disease treatment. Based on the differences in their pathological and physiological mechanisms, many methods have been developed so far to differentiate AIT subtypes such as colour flow Doppler sonography (CFDS) and 24-h radioiodine uptake (RAIU). However, these methods suffer from inadequate accuracy in distinguishing different types of AITs and sometimes lead to misdiagnosis and delayed treatments. Therefore, there is an unmet demand for an efficient method for accurate classification of AIT. Methods: Technetium-99 methoxyisobutylisonitrile (99mTc-MIBI) thyroid imaging was performed on 15 patients for AIT classification, and the results were compared with other conventional methods such as CFDS, RAIU and 99mTcO4 imaging. Results: High uptake and retention of MIBI in thyroid tissue is characteristic in Type I AIT, while in sharp contrast, low uptake of MIBI in the thyroid tissue was observed in Type II AIT. Mixed-type AIT shows uptake value between Types I and II. MIBI imaging outperforms other methods with a lower misdiagnosis rate. Conclusion: Among the methods evaluated, MIBI imaging enables an accurate identification of Type I, II and mixed-type AITs by showing distinct images for different types of AITs. The results obtained from our selected subjects revealed that MIBI imaging is a reliable method for diagnosis and classification of AITs and MIBI imaging has potential in the treatment of thyroid diseases. Advances in knowledge: 99mTc-MIBI imaging is a useful method for the diagnosis of AIT. It can distinguish different types of AITs especially for mixed-type AIT, which is usually difficult to treat. 99mTc-MIBI has potential advantages over conventional methods in the efficient treatment of AIT. PMID:28106465

  20. Manufacturing Methods and Technology Application of High Energy Laser Welding Process.

    DTIC Science & Technology

    1980-08-01

    surface appearance and the lowest porosity of the three beam shapes evaluated. Welds made with the pure annular beam resembled a TIG weld in both surface...improper starts and stops when welding with a conventional MIG or TIG process. Figure 16 left and center illustrates cracking due to fast freezing conditions...REPORT RL-82-2 0 MANUFACTURING METHODS AND TECHNOLOGY APPLICATION _OF HIGH ENERGY LASER WELDING PROCESS 0John V. Melonas Structures Directorate, U S

  1. Accuracy of Conventional PCR Targeting the 16S rRNA Gene with the Ot-16sRF1 and Ot-16sRR1 Primers for Diagnosis of Scrub Typhus: a Case-Control Study

    PubMed Central

    Kim, Choon-Mee; Cho, Min Keun; Yun, Na-Ra; Kim, Seok Won; Jang, Sook Jin; Ahn, Young-Joon; Lim, Donghoon

    2015-01-01

    We retrospectively evaluated the accuracy of conventional PCR targeting the 16S rRNA gene (16S C-PCR) using the Ot-16sRF1/Ot-16sRR1 primers for diagnosing scrub typhus. The diagnosis of Orientia tsutsugamushi infection by 16S C-PCR presented an increased sensitivity of 87.0% and specificity of 100% compared with those obtained with other targets and is thus a simple and clinically useful method with good diagnostic accuracy. PMID:26491185

  2. On-demand calibration and evaluation for electromagnetically tracked laparoscope in augmented reality visualization.

    PubMed

    Liu, Xinyang; Plishker, William; Zaki, George; Kang, Sukryool; Kane, Timothy D; Shekhar, Raj

    2016-06-01

    Common camera calibration methods employed in current laparoscopic augmented reality systems require the acquisition of multiple images of an entire checkerboard pattern from various poses. This lengthy procedure prevents performing laparoscope calibration in the operating room (OR). The purpose of this work was to develop a fast calibration method for electromagnetically (EM) tracked laparoscopes, such that the calibration can be performed in the OR on demand. We designed a mechanical tracking mount to uniquely and snugly position an EM sensor to an appropriate location on a conventional laparoscope. A tool named fCalib was developed to calibrate intrinsic camera parameters, distortion coefficients, and extrinsic parameters (transformation between the scope lens coordinate system and the EM sensor coordinate system) using a single image that shows an arbitrary portion of a special target pattern. For quick evaluation of calibration results in the OR, we integrated a tube phantom with fCalib prototype and overlaid a virtual representation of the tube on the live video scene. We compared spatial target registration error between the common OpenCV method and the fCalib method in a laboratory setting. In addition, we compared the calibration re-projection error between the EM tracking-based fCalib and the optical tracking-based fCalib in a clinical setting. Our results suggest that the proposed method is comparable to the OpenCV method. However, changing the environment, e.g., inserting or removing surgical tools, might affect re-projection accuracy for the EM tracking-based approach. Computational time of the fCalib method averaged 14.0 s (range 3.5 s-22.7 s). We developed and validated a prototype for fast calibration and evaluation of EM tracked conventional (forward viewing) laparoscopes. The calibration method achieved acceptable accuracy and was relatively fast and easy to be performed in the OR on demand.

  3. Effects of competitive computer-assisted learning versus conventional teaching methods on the acquisition and retention of knowledge in medical surgical nursing students.

    PubMed

    Fernández Alemán, José Luis; Carrillo de Gea, Juan Manuel; Rodríguez Mondéjar, Juan José

    2011-11-01

    This paper presents a novel approach of computer-assisted learning for nursing education in university undergraduate courses. The most innovative aspect of the proposal is the design of nursing assignments as on-line competitions. The effects of competitive e-learning versus conventional teaching methods on the acquisition and retention of knowledge were compared in a course on medical-surgical nursing. A total of 116 students of mixed gender, age, computer experience and educational background in a second-year course on medical-surgical nursing participated in the study. Data were collected from nursing students at four time points. The on-line activities were carried out using a web-based automatic evaluation system. The study revealed that the competitive e-learning method produced significant cognitive gains for the experimental group students in the immediate follow-up test. Nevertheless, both teaching methods resulted in similar knowledge retention in the 10-week follow-up test. Significant benefits were found following our approach. The work of the students could be evaluated along the course, the workload of instructors was reduced and students received immediate feedback by the on-line judge, which promoted both independent learning and reflective thinking. The approach is applicable to any other nursing educational institution. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Quality evaluation of Semen Cassiae (Cassia obtusifolia L.) by using ultra-high performance liquid chromatography coupled with mass spectrometry.

    PubMed

    Zhang, Wei-Dong; Wang, Ying; Wang, Qing; Yang, Wan-Jun; Gu, Yi; Wang, Rong; Song, Xiao-Mei; Wang, Xiao-Juan

    2012-08-01

    A sensitive and reliable ultra-high performance liquid chromatography-electrospray ionization-tandem mass spectrometry has been developed and partially validated to evaluate the quality of Semen Cassiae (Cassia obtusifolia L.) through simultaneous determination of 11 anthraquinones and two naphtha-γ-pyrone compounds. The analysis was achieved on a Poroshell 120 EC-C(18) column (100 mm × 2.1 mm, 2.7 μm; Agilent, Palo Alto, CA, USA) with gradient elution using a mobile phase that consisted of acetonitrile-water (30 mM ammonium acetate) at a flow rate of 0.4 mL/min. For quantitative analysis, all calibration curves showed perfect linear regression (r(2) > 0.99) within the testing range. This method was also validated with respect to precision and accuracy, and was successfully applied to quantify the 13 components in nine batches of Semen Cassiae samples from different areas. The performance of developed method was compared with that of conventional high-performance liquid chromatography method. The significant advantages of the former include high-speed chromatographic separation, four times faster than high-performance liquid chromatography with conventional columns, and great enhancement in sensitivity. This developed method provided a new basis for overall assessment on quality of Semen Cassiae. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Techniques for control of long-term reliability of complex integrated circuits. I - Reliability assurance by test vehicle qualification.

    NASA Technical Reports Server (NTRS)

    Van Vonno, N. W.

    1972-01-01

    Development of an alternate approach to the conventional methods of reliability assurance for large-scale integrated circuits. The product treated is a large-scale T squared L array designed for space applications. The concept used is that of qualification of product by evaluation of the basic processing used in fabricating the product, providing an insight into its potential reliability. Test vehicles are described which enable evaluation of device characteristics, surface condition, and various parameters of the two-level metallization system used. Evaluation of these test vehicles is performed on a lot qualification basis, with the lot consisting of one wafer. Assembled test vehicles are evaluated by high temperature stress at 300 C for short time durations. Stressing at these temperatures provides a rapid method of evaluation and permits a go/no go decision to be made on the wafer lot in a timely fashion.

  6. Cost-Utility Analysis of the EVOLVO Study on Remote Monitoring for Heart Failure Patients With Implantable Defibrillators: Randomized Controlled Trial

    PubMed Central

    Landolina, Maurizio; Marzegalli, Maurizio; Lunati, Maurizio; Perego, Giovanni B; Guenzati, Giuseppe; Curnis, Antonio; Valsecchi, Sergio; Borghetti, Francesca; Borghi, Gabriella; Masella, Cristina

    2013-01-01

    Background Heart failure patients with implantable defibrillators place a significant burden on health care systems. Remote monitoring allows assessment of device function and heart failure parameters, and may represent a safe, effective, and cost-saving method compared to conventional in-office follow-up. Objective We hypothesized that remote device monitoring represents a cost-effective approach. This paper summarizes the economic evaluation of the Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study, a multicenter clinical trial aimed at measuring the benefits of remote monitoring for heart failure patients with implantable defibrillators. Methods Two hundred patients implanted with a wireless transmission–enabled implantable defibrillator were randomized to receive either remote monitoring or the conventional method of in-person evaluations. Patients were followed for 16 months with a protocol of scheduled in-office and remote follow-ups. The economic evaluation of the intervention was conducted from the perspectives of the health care system and the patient. A cost-utility analysis was performed to measure whether the intervention was cost-effective in terms of cost per quality-adjusted life year (QALY) gained. Results Overall, remote monitoring did not show significant annual cost savings for the health care system (€1962.78 versus €2130.01; P=.80). There was a significant reduction of the annual cost for the patients in the remote arm in comparison to the standard arm (€291.36 versus €381.34; P=.01). Cost-utility analysis was performed for 180 patients for whom QALYs were available. The patients in the remote arm gained 0.065 QALYs more than those in the standard arm over 16 months, with a cost savings of €888.10 per patient. Results from the cost-utility analysis of the EVOLVO study show that remote monitoring is a cost-effective and dominant solution. Conclusions Remote management of heart failure patients with implantable defibrillators appears to be cost-effective compared to the conventional method of in-person evaluations. Trial Registration ClinicalTrials.gov NCT00873899; http://clinicaltrials.gov/show/NCT00873899 (Archived by WebCite at http://www.webcitation.org/6H0BOA29f). PMID:23722666

  7. Reliability of clinical guideline development using mail-only versus in-person expert panels.

    PubMed

    Washington, Donna L; Bernstein, Steven J; Kahan, James P; Leape, Lucian L; Kamberg, Caren J; Shekelle, Paul G

    2003-12-01

    Clinical practice guidelines quickly become outdated. One reason they might not be updated as often as needed is the expense of collecting expert judgment regarding the evidence. The RAND-UCLA Appropriateness Method is one commonly used method for collecting expert opinion. We tested whether a less expensive, mail-only process could substitute for the standard in-person process normally used. We performed a 4-way replication of the appropriateness panel process for coronary revascularization and hysterectomy, conducting 3 panels using the conventional in-person method and 1 panel entirely by mail. All indications were classified as inappropriate or not (to evaluate overuse), and coronary revascularization indications were classified as necessary or not (to evaluate underuse). Kappa statistics were calculated for the comparison in ratings from the 2 methods. Agreement beyond chance between the 2 panel methods ranged from moderate to substantial. The kappa statistic to detect overuse was 0.57 for coronary revascularization and 0.70 for hysterectomy. The kappa statistic to detect coronary revascularization underuse was 0.76. There were no cases in which coronary revascularization was considered inappropriate by 1 method, but necessary or appropriate by the other. Three of 636 (0.5%) hysterectomy cases were categorized as inappropriate by 1 method but appropriate by the other. The reproducibility of the overuse and underuse assessments from the mail-only compared with the conventional in-person conduct of expert panels in this application was similar to the underlying reproducibility of the process. This suggests a potential role for updating guidelines using an expert judgment process conducted entirely through the mail.

  8. Same-Day Identification and Antimicrobial Susceptibility Testing of Bacteria in Positive Blood Culture Broths Using Short-Term Incubation on Solid Medium with the MicroFlex LT, Vitek-MS, and Vitek2 Systems

    PubMed Central

    Ha, Jihye; Han, Geum Hee; Kim, Myungsook; Lee, Kyungwon

    2018-01-01

    Background Early and appropriate antibiotic treatment improves the clinical outcome of patients with septicemia; therefore, reducing the turn-around time for identification (ID) and antimicrobial susceptibility test (AST) results is essential. We established a method for rapid ID and AST using short-term incubation of positive blood culture broth samples on solid media, and evaluated its performance relative to that of the conventional method using two rapid ID systems and a rapid AST method. Methods A total of 254 mono-microbial samples were included. Positive blood culture samples were incubated on blood agar plates for six hours and identified by the MicroFlex LT (Bruker Daltonics) and Vitek-MS (bioMeriéux) systems, followed by AST using the Vitek2 System (bioMeriéux). Results The correct species-level ID rates were 82.3% (209/254) and 78.3% (199/254) for the MicroFlex LT and Vitek-MS platforms, respectively. For the 1,174 microorganism/antimicrobial agent combinations tested, the rapid AST method showed total concordance of 97.8% (1,148/1,174) with the conventional method, with a very major error rate of 0.5%, major error rate of 0.7%, and minor error rate of 1.0%. Conclusions Routine implementation of this short-term incubation method could provide ID results on the day of blood culture-positivity detection and one day earlier than the conventional AST method. This simple method will be very useful for rapid ID and AST of bacteria from positive blood culture bottles in routine clinical practice. PMID:29401558

  9. The new analysis method of PWQ in the DRAM pattern

    NASA Astrophysics Data System (ADS)

    Han, Daehan; Chang, Jinman; Kim, Taeheon; Lee, Kyusun; Kim, Yonghyeon; Kang, Jinyoung; Hong, Aeran; Choi, Bumjin; Lee, Joosung; Kim, Hyoung Jun; Lee, Kweonjae; Hong, Hyoungsun; Jin, Gyoyoung

    2016-03-01

    In a sub 2Xnm node process, the feedback of pattern weak points is more and more significant. Therefore, it is very important to extract the systemic defect in Double Patterning Technology(DPT), however, it is impossible to predict exact systemic defect at the recent photo simulation tool.[1] Therefore, the method of Process Window Qualification (PWQ) is very serious and essential these days. Conventional PWQ methods are die to die image comparison by using an e-beam or bright field machine. Results are evaluated by the person, who reviews the images, in some cases. However, conventional die to die comparison method has critical problem. If reference die and comparison die have same problem, such as both of dies have pattern problems, the issue patterns are not detected by current defect detecting approach. Aside from the inspection accuracy, reviewing the wafer requires much effort and time to justify the genuine issue patterns. Therefore, our company adopts die to data based matching PWQ method that is using NGR machine. The main features of the NGR are as follows. First, die to data based matching, second High speed, finally massive data were used for evaluation of pattern inspection.[2] Even though our die to data based matching PWQ method measures the mass data, our margin decision process is based on image shape. Therefore, it has some significant problems. First, because of the long analysis time, the developing period of new device is increased. Moreover, because of the limitation of resources, it may not examine the full chip area. Consequently, the result of PWQ weak points cannot represent the all the possible defects. Finally, since the PWQ margin is not decided by the mathematical value, to make the solid definition of killing defect is impossible. To overcome these problems, we introduce a statistical values base process window qualification method that increases the accuracy of process margin and reduces the review time. Therefore, it is possible to see the genuine margin of the critical pattern issue which we cannot see on our conventional PWQ inspection; hence we can enhance the accuracy of PWQ margin.

  10. A Quantitative and Standardized Method for the Evaluation of Choroidal Neovascularization Using MICRON III Fluorescein Angiograms in Rats

    PubMed Central

    Wigg, Jonathan P.; Zhang, Hong; Yang, Dong

    2015-01-01

    Introduction In-vivo imaging of choroidal neovascularization (CNV) has been increasingly recognized as a valuable tool in the investigation of age-related macular degeneration (AMD) in both clinical and basic research applications. Arguably the most widely utilised model replicating AMD is laser generated CNV by rupture of Bruch’s membrane in rodents. Heretofore CNV evaluation via in-vivo imaging techniques has been hamstrung by a lack of appropriate rodent fundus camera and a non-standardised analysis method. The aim of this study was to establish a simple, quantifiable method of fluorescein fundus angiogram (FFA) image analysis for CNV lesions. Methods Laser was applied to 32 Brown Norway Rats; FFA images were taken using a rodent specific fundus camera (Micron III, Phoenix Laboratories) over 3 weeks and compared to conventional ex-vivo CNV assessment. FFA images acquired with fluorescein administered by intraperitoneal injection and intravenous injection were compared and shown to greatly influence lesion properties. Utilising commonly used software packages, FFA images were assessed for CNV and chorioretinal burns lesion area by manually outlining the maximum border of each lesion and normalising against the optic nerve head. Net fluorescence above background and derived value of area corrected lesion intensity were calculated. Results CNV lesions of rats treated with anti-VEGF antibody were significantly smaller in normalised lesion area (p<0.001) and fluorescent intensity (p<0.001) than the PBS treated control two weeks post laser. The calculated area corrected lesion intensity was significantly smaller (p<0.001) in anti-VEGF treated animals at 2 and 3 weeks post laser. The results obtained using FFA correlated with, and were confirmed by conventional lesion area measurements from isolectin stained choroidal flatmounts, where lesions of anti-VEGF treated rats were significantly smaller at 2 weeks (p = 0.049) and 3 weeks (p<0.001) post laser. Conclusion The presented method of in-vivo FFA quantification of CNV, including acquisition variable corrections, using the Micron III system and common use software establishes a reliable method for detecting and quantifying CNV enabling longitudinal studies and represents an important alternative to conventional CNV quantification methods. PMID:26024231

  11. A comment on "Novel scavenger removal trials increase wind turbine-caused avian fatality estimates"

    USGS Publications Warehouse

    Huso, Manuela M.P.; Erickson, Wallace P.

    2013-01-01

    In a recent paper, Smallwood et al. (2010) conducted a study to compare their “novel” approach to conducting carcass removal trials with what they term the “conventional” approach and to evaluate the effects of the different methods on estimated avian fatality at a wind power facility in California. A quick glance at Table 3 that succinctly summarizes their results and provides estimated fatality rates and 80% confidence intervals calculated using the 2 methods reveals a surprising result. The confidence intervals of all of their estimates and most of the conventional estimates extend below 0. These results imply that wind turbines may have the capacity to create live birds. But a more likely interpretation is that a serious error occurred in the calculation of either the average fatality rate or its standard error or both. Further evaluation of their methods reveals that the scientific basis for concluding that “many estimates of scavenger removal rates prior to [their] study were likely biased low due to scavenger swamping” and “previously reported estimates of avian fatality rates … should be adjusted upwards” was not evident in their analysis and results. Their comparison to conventional approaches was not applicable, their statistical models were questionable, and the conclusions they drew were unsupported.

  12. Comparative evaluation of endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe in obturation of primary teeth: An in vitro study.

    PubMed

    Hiremath, Mallayya C; Srivastava, Pooja

    2016-01-01

    The purpose of this in vitro study was to compare four methods of root canal obturation in primary teeth using conventional radiography. A total of 96 root canals of primary molars were prepared and obturated with zinc oxide eugenol. Obturation methods compared were endodontic pressure syringe, insulin syringe, jiffy tube, and local anesthetic syringe. The root canal obturations were evaluated by conventional radiography for the length of obturation and presence of voids. The obtained data were analyzed using Chi-square test. The results showed significant differences between the four groups for the length of obturation (P < 0.05). The endodontic pressure syringe showed the best results (98.5% optimal fillings) and jiffy tube showed the poor results (37.5% optimal fillings) for the length of obturation. The insulin syringe (79.2% optimal fillings) and local anesthetic syringe (66.7% optimal fillings) showed acceptable results for the length of root canal obturation. However, minor voids were present in all the four techniques used. Endodontic pressure syringe produced the best results in terms of length of obturation and controlling paste extrusion from the apical foramen. However, insulin syringe and local anesthetic syringe can be used as effective alternative methods.

  13. Application of dynamic programming to evaluate the slope stability of a vertical extension to a balefill.

    PubMed

    Kremen, Arie; Tsompanakis, Yiannis

    2010-04-01

    The slope-stability of a proposed vertical extension of a balefill was investigated in the present study, in an attempt to determine a geotechnically conservative design, compliant with New Jersey Department of Environmental Protection regulations, to maximize the utilization of unclaimed disposal capacity. Conventional geotechnical analytical methods are generally limited to well-defined failure modes, which may not occur in landfills or balefills due to the presence of preferential slip surfaces. In addition, these models assume an a priori stress distribution to solve essentially indeterminate problems. In this work, a different approach has been applied, which avoids several of the drawbacks of conventional methods. Specifically, the analysis was performed in a two-stage process: (a) calculation of stress distribution, and (b) application of an optimization technique to identify the most probable failure surface. The stress analysis was performed using a finite element formulation and the location of the failure surface was located by dynamic programming optimization method. A sensitivity analysis was performed to evaluate the effect of the various waste strength parameters of the underlying mathematical model on the results, namely the factor of safety of the landfill. Although this study focuses on the stability investigation of an expanded balefill, the methodology presented can easily be applied to general geotechnical investigations.

  14. Identification of bacteria isolated from veterinary clinical specimens using MALDI-TOF MS.

    PubMed

    Pavlovic, Melanie; Wudy, Corinna; Zeller-Peronnet, Veronique; Maggipinto, Marzena; Zimmermann, Pia; Straubinger, Alix; Iwobi, Azuka; Märtlbauer, Erwin; Busch, Ulrich; Huber, Ingrid

    2015-01-01

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has recently emerged as a rapid and accurate identification method for bacterial species. Although it has been successfully applied for the identification of human pathogens, it has so far not been well evaluated for routine identification of veterinary bacterial isolates. This study was performed to compare and evaluate the performance of MALDI-TOF MS based identification of veterinary bacterial isolates with commercially available conventional test systems. Discrepancies of both methods were resolved by sequencing 16S rDNA and, if necessary, the infB gene for Actinobacillus isolates. A total of 375 consecutively isolated veterinary samples were collected. Among the 357 isolates (95.2%) correctly identified at the genus level by MALDI-TOF MS, 338 of them (90.1% of the total isolates) were also correctly identified at the species level. Conventional methods offered correct species identification for 319 isolates (85.1%). MALDI-TOF identification therefore offered more accurate identification of veterinary bacterial isolates. An update of the in-house mass spectra database with additional reference spectra clearly improved the identification results. In conclusion, the presented data suggest that MALDI-TOF MS is an appropriate platform for classification and identification of veterinary bacterial isolates.

  15. [Evaluation method with radiographic image quality indicator for internal defects of dental casting metallic restoration].

    PubMed

    Li, Y; Zheng, G; Lin, H

    2014-12-18

    To develop a new kind of dental radiographic image quality indicator (IQI) for internal quality of casting metallic restoration to influence on its usage life. Radiographic image quality indicator method was used to evaluate the depth of the defects region and internal quality of 127 casting metallic restoration and the accuracy was compared with that of conventional callipers method. In the 127 cases of casting metallic restoration, 9 were found the thickness less than 0.7 mm and the thinnest thickness only 0.2 mm in 26 casting metallic crowns or bridges' occlusal defects region. The data measured by image quality indicator were consistent with those measured by conventional gauging. Two metal inner crowns were found the thickness less than 0.3 mm in 56 porcelain crowns or bridges. The thickness of casting removable partial denture was more than 1.0 mm, but thinner regions were not found. It was found that in a titanium partial denture, the X-ray image of clasp was not uniform and there were internal porosity defects in the clasp. Special dental image quality indicator can solve the visual error problems caused by different observing backgrounds and estimate the depth of the defects region in the casting.

  16. Measuring the effectiveness of protected area networks in reducing deforestation.

    PubMed

    Andam, Kwaw S; Ferraro, Paul J; Pfaff, Alexander; Sanchez-Azofeifa, G Arturo; Robalino, Juan A

    2008-10-21

    Global efforts to reduce tropical deforestation rely heavily on the establishment of protected areas. Measuring the effectiveness of these areas is difficult because the amount of deforestation that would have occurred in the absence of legal protection cannot be directly observed. Conventional methods of evaluating the effectiveness of protected areas can be biased because protection is not randomly assigned and because protection can induce deforestation spillovers (displacement) to neighboring forests. We demonstrate that estimates of effectiveness can be substantially improved by controlling for biases along dimensions that are observable, measuring spatial spillovers, and testing the sensitivity of estimates to potential hidden biases. We apply matching methods to evaluate the impact on deforestation of Costa Rica's renowned protected-area system between 1960 and 1997. We find that protection reduced deforestation: approximately 10% of the protected forests would have been deforested had they not been protected. Conventional approaches to evaluating conservation impact, which fail to control for observable covariates correlated with both protection and deforestation, substantially overestimate avoided deforestation (by over 65%, based on our estimates). We also find that deforestation spillovers from protected to unprotected forests are negligible. Our conclusions are robust to potential hidden bias, as well as to changes in modeling assumptions. Our results show that, with appropriate empirical methods, conservation scientists and policy makers can better understand the relationships between human and natural systems and can use this to guide their attempts to protect critical ecosystem services.

  17. A noninvasive method of examination of the hemostasis system.

    PubMed

    Kuznik, B I; Fine, I W; Kaminsky, A V

    2011-09-01

    We propose a noninvasive method of in vivo examination the hemostasis system based on speckle pattern analysis of coherent light scattering from the skin. We compared the results of measuring basic blood coagulation parameters by conventional invasive and noninvasive methods. A strict correlation was found between the results of measurement of soluble fibrin monomer complexes, international normalized ratio (INR), prothrombin index, and protein C content. The noninvasive method of examination of the hemostatic system enable rough evaluation of the intensity of the intravascular coagulation and correction of the dose of indirect anticoagulants maintaining desired values of INR or prothrombin index.

  18. Dental enamel defect diagnosis through different technology-based devices.

    PubMed

    Kobayashi, Tatiana Yuriko; Vitor, Luciana Lourenço Ribeiro; Carrara, Cleide Felício Carvalho; Silva, Thiago Cruvinel; Rios, Daniela; Machado, Maria Aparecida Andrade Moreira; Oliveira, Thais Marchini

    2018-06-01

    Dental enamel defects (DEDs) are faulty or deficient enamel formations of primary and permanent teeth. Changes during tooth development result in hypoplasia (a quantitative defect) and/or hypomineralisation (a qualitative defect). To compare technology-based diagnostic methods for detecting DEDs. Two-hundred and nine dental surfaces of anterior permanent teeth were selected in patients, 6-11 years of age, with cleft lip with/without cleft palate. First, a conventional clinical examination was conducted according to the modified Developmental Defects of Enamel Index (DDE Index). Dental surfaces were evaluated using an operating microscope and a fluorescence-based device. Interexaminer reproducibility was determined using the kappa test. To compare groups, McNemar's test was used. Cramer's V test was used for comparing the distribution of index codes obtained after classification of all dental surfaces. Cramer's V test revealed statistically significant differences (P < .0001) in the distribution of index codes obtained using the different methods; the coefficients were 0.365 for conventional clinical examination versus fluorescence, 0.961 for conventional clinical examination versus operating microscope and 0.358 for operating microscope versus fluorescence. The sensitivity of the operating microscope and fluorescence method was statistically significant (P = .008 and P < .0001, respectively). Otherwise, the results did not show statistically significant differences in accuracy and specificity for either the operating microscope or the fluorescence methods. This study suggests that the operating microscope performed better than the fluorescence-based device and could be an auxiliary method for the detection of DEDs. © 2017 FDI World Dental Federation.

  19. Applications of rapid prototyping technology in maxillofacial prosthetics.

    PubMed

    Sykes, Leanne M; Parrott, Andrew M; Owen, C Peter; Snaddon, Donald R

    2004-01-01

    The purpose of this study was to compare the accuracy, required time, and potential advantages of rapid prototyping technology with traditional methods in the manufacture of wax patterns for two facial prostheses. Two clinical situations were investigated: the production of an auricular prosthesis and the duplication of an existing maxillary prosthesis, using a conventional and a rapid prototyping method for each. Conventional wax patterns were created from impressions taken of a patient's remaining ear and an oral prosthesis. For the rapid prototyping method, a cast of the ear and the original maxillary prosthesis were scanned, and rapid prototyping was used to construct the wax patterns. For the auricular prosthesis, both patterns were refined clinically and then flasked and processed in silicone using routine procedures. Twenty-six independent observers evaluated these patterns by comparing them to the cast of the patient's remaining ear. For the duplication procedure, both wax patterns were scanned and compared to scans of the original prosthesis by generating color error maps to highlight volumetric changes. There was a significant difference in opinions for the two auricular prostheses with regard to shape and esthetic appeal, where the hand-carved prosthesis was found to be of poorer quality. The color error maps showed higher errors with the conventional duplication process compared with the rapid prototyping method. The main advantage of rapid prototyping is the ability to produce physical models using digital methods instead of traditional impression techniques. The disadvantage of equipment costs could be overcome by establishing a centralized service.

  20. Preparation, composition and functional properties of pennycress (Thlaspi arvense L.) seed protein isolates

    USDA-ARS?s Scientific Manuscript database

    This study evaluated two methods, saline extraction (SE) and conventional acid precipitation (AP), to recover proteins from pennycress (Thlaspi arvense L.) seed meal. SE was done using 0.1 M NaCl at 50ºC while AP involved alkaline extraction (pH 10) first followed by protein precipitation at pH 4. C...

Top