Sample records for conventional hplc method

  1. Conventional high-performance liquid chromatography versus derivative spectrophotometry for the determination of 1,3,6-pyrenetrisulfonic acid trisodium salt and 1,3,6,8-pyrenetetrasulfonic acid tetrasodium salt in the color additive D&C Green No. 8 (Pyranine).

    PubMed

    Jitian, Simion; White, Samuel R; Yang, H-H Wendy; Weisz, Adrian

    2014-01-10

    Specifications in the U.S. Code of Federal Regulations for the color additive D&C Green No. 8 (Colour Index No. 59040) limit the levels of the subsidiary colors 1,3,6-pyrenetrisulfonic acid trisodium salt (P3S) and 1,3,6,8-pyrenetetrasulfonic acid tetrasodium salt (P4S). The present paper describes a comparative study of two possible methods to replace the currently used multi-step TLC/spectrophotometry method of separating and quantifying the minor components P3S and P4S in G8. One of the new approaches uses conventional high-performance liquid chromatography (HPLC) and the other, derivative spectrophotometry. While the derivative spectrophotometric method was shown to be inadequate for the analysis of minor components overwhelmed by components of much higher concentration, the HPLC method was proven highly effective. The closely related, very polar compounds P3S and P4S were separated by the new HPLC method in less than 4 min using a conventional HPLC instrument. P3S and P4S were quantified by using five-point calibration curves with data points that ranged from 0.45 to 7.63% and from 0.13 to 1.82%, by weight, for P3S and P4S, respectively. The HPLC method was applied to the analysis of test portions from 20 batches of D&C Green No. 8 submitted to the U.S. Food and Drug Administration for certification. Published by Elsevier B.V.

  2. Modified HPLC-ESI-MS Method for Glycated Hemoglobin Quantification Based on the IFCC Reference Measurement Procedure and Its Application for Quantitative Analyses in Clinical Laboratories of China.

    PubMed

    Song, Zhixin; Xie, Baoyuan; Ma, Huaian; Zhang, Rui; Li, Pengfei; Liu, Lihong; Yue, Yuhong; Zhang, Jianping; Tong, Qing; Wang, Qingtao

    2016-09-01

    The level of glycated hemoglobin (HbA1c ) has been recognized as an important indicator of long-term glycemic control. However, the HbA1c measurement is not currently included as a diagnostic determinant in China. Current study aims to assess a candidate modified International Federation of Clinical Chemistry reference method for the forthcoming standardization of HbA1c measurements in China. The HbA1c concentration was measured using a modified high-performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) method. The modified method replaces the propylcyanide column with a C18 reversed-phase column, which has a lower cost and is more commonly used in China, and uses 0.1% (26.5 mmol/l) formic acid instead of trifluoroacetic acid. Moreover, in order to minimize matrix interference and reduce the running time, a solid-phase extraction was employed. The discrepancies between HbA1c measurements using conventional methods and the HPLC-ESI-MS method were clarified in clinical samples from healthy people and diabetic patients. Corresponding samples were distributed to 89 hospitals in Beijing for external quality assessment. The linearity, reliability, and accuracy of the modified HPLC-ESI-MS method with a shortened running time of 6 min were successfully validated. Out of 89 hospitals evaluated, the relative biases of HbA1c concentrations were < 8% for 74 hospitals and < 5% for 60 hospitals. Compared with other conventional methods, HbA1c concentrations determined by HPLC methods were similar to the values obtained from the current HPLC-ESI-MS method. The HPLC-ESI-MS method represents an improvement over existing methods and provides a simple, stable, and rapid HbA1c measurement with strong signal intensities and reduced ion suppression. © 2015 Wiley Periodicals, Inc.

  3. Characterization of organic and conventional sweet basil leaves using chromatographic and flow-injection mass spectrometric (FIMS) fingerprints combined with principal component analysis

    PubMed Central

    Lu, Yingjian; Gao, Boyan; Chen, Pei; Charles, Denys; Yu, Liangli (Lucy)

    2014-01-01

    Sweet basil, Ocimum basilicum., is one of the most important and wildly used spices and has been shown to have antioxidant, antibacterial, and anti-diarrheal activities. In this study, high performance liquid chromatographic (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were used to differentiate organic and conventional sweet basil leaf samples. Principal component analysis (PCA) of the fingerprints indicated that both HPLC and FIMS fingerprints could effectively detect the chemical differences in the organic and conventional sweet basil leaf samples. This study suggested that the organic basil sample contained greater concentrations of almost all the major compounds than its conventional counterpart on a per same botanical weight basis. The FIMS method was able to rapidly differentiate the organic and conventional sweet basil leaf samples (1 min analysis time), whereas the HPLC fingerprints provided more information about the chemical composition of the basil samples with a longer analytical time. PMID:24518341

  4. Characterisation of organic and conventional sweet basil leaves using chromatographic and flow-injection mass spectrometric (FIMS) fingerprints combined with principal component analysis.

    PubMed

    Lu, Yingjian; Gao, Boyan; Chen, Pei; Charles, Denys; Yu, Liangli Lucy

    2014-07-01

    Sweet basil, Ocimum basilicum, is one of the most important and wildly used spices and has been shown to have antioxidant, antibacterial, and anti-diarrheal activities. In this study, high performance liquid chromatographic (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were used to differentiate organic and conventional sweet basil leaf samples. Principal component analysis (PCA) of the fingerprints indicated that both HPLC and FIMS fingerprints could effectively detect the chemical differences in the organic and conventional sweet basil leaf samples. This study suggested that the organic basil sample contained greater concentrations of almost all the major compounds than its conventional counterpart on a per same botanical weight basis. The FIMS method was able to rapidly differentiate the organic and conventional sweet basil leaf samples (1min analysis time), whereas the HPLC fingerprints provided more information about the chemical composition of the basil samples with a longer analytical time. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Comparison on extraction yield of sennoside A and sennoside B from senna (Cassia angustifolia) using conventional and non conventional extraction techniques and their quantification using a validated HPLC-PDA detection method.

    PubMed

    Dhanani, Tushar; Singh, Raghuraj; Reddy, Nagaraja; Trivedi, A; Kumar, Satyanshu

    2017-05-01

    Senna is an important medicinal plant and is used in many Ayurvedic formulations. Dianthraquinone glucosides are the main bioactive phytochemicals present in leaves and pods of senna. The extraction efficiency in terms of yield and composition of the extract of senna prepared using both conventional (cold percolation at room temperature and refluxing) and non conventional (ultrasound and microwave assisted solvent extraction as well as supercritical fluid extraction) techniques were compared in the present study. Also a rapid reverse phase HPLC-PDA detection method was developed and validated for the simultaneous determination of sennoside A and sennoside B in the different extracts of senna leaves. Ultrasound and microwave assisted solvent extraction techniques were more effective in terms of yield and composition of the extracts compared to cold percolation at room temperature and refluxing methods of extraction.

  6. Determination of sulfonamides and trimethoprim using high temperature HPLC with simultaneous temperature and solvent gradient.

    PubMed

    Giegold, Sascha; Teutenberg, Thorsten; Tuerk, Jochen; Kiffmeyer, Thekla; Wenclawiak, Bernd

    2008-10-01

    A fast HPLC method for the analysis of eight selected sulfonamides (SA) and trimethoprim has been developed with the use of high temperature HPLC. The separation could be achieved in less than 1.5 min on a 50 mm sub 2 microm column with simultaneous solvent and temperature gradient programming. Due to the lower viscosity of the mobile phase and the increased mass transfer at higher temperatures, the separation could be performed on a conventional HPLC system obtaining peak widths at half height between 0.6 and 1.3 s.

  7. Steroids

    NASA Astrophysics Data System (ADS)

    Frey, Felix J.; Frey, Brigitte M.; Benet, Leslie Z.

    If a radioimmunoassay, a protein binding method, or a colorimetric assay for the assessment of a steroid level is replaced by high performance liquid chromatography (HPLC), the cost for the determination of a steroid level increases at least initially because one must acquire the new HPLC equipment. Therefore, if an older method provides the same results as the new, "advanced" HPLC method, the only advantage resulting from the introduction of a high performance chromatographic assay is that gained by the manufacturer in terms of greater sales. Thus, justification for the assessment of steroids by HPLC is only obtained if the quality and/or quantity of information gained is significantly increased as compared to that provided by the conventional methods. But this evidential relation, that more and better information justifies a higher price in any case, is no longer true in health care, with the birth some years ago of the categoric imperative for the reduction of costs in the medical sector. That is, each new technology introduced for health maintenance should demonstrate at least a stabilizing impact on total medical expenditures. Therefore, after reviewing the presently available HPLC methods for the clinically important steroids, we will consider whether HPLC analyses for these steroids can be recommended without violating this vox populi.

  8. Differentiating organic from conventional peppermints using chromatographic and flow-injection mass spectrometric (FIMS) fingerprints

    USDA-ARS?s Scientific Manuscript database

    High performance liquid chromatography (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were tested for their potential in differentiating organic and conventional peppermint samples. Ten organic and ten conventional peppermint samples were examined using HPLC-UV and FI...

  9. Monitoring the chemical production of citrus-derived bioactive 5-demethylnobiletin using surface enhanced Raman spectroscopy

    PubMed Central

    Zheng, Jinkai; Fang, Xiang; Cao, Yong; Xiao, Hang; He, Lili

    2013-01-01

    To develop an accurate and convenient method for monitoring the production of citrus-derived bioactive 5-demethylnobiletin from demethylation reaction of nobiletin, we compared surface enhanced Raman spectroscopy (SERS) methods with a conventional HPLC method. Our results show that both the substrate-based and solution-based SERS methods correlated with HPLC method very well. The solution method produced lower root mean square error of calibration and higher correlation coefficient than the substrate method. The solution method utilized an ‘affinity chromatography’-like procedure to separate the reactant nobiletin from the product 5-demthylnobiletin based on their different binding affinity to the silver dendrites. The substrate method was found simpler and faster to collect the SERS ‘fingerprint’ spectra of the samples as no incubation between samples and silver was needed and only trace amount of samples were required. Our results demonstrated that the SERS methods were superior to HPLC method in conveniently and rapidly characterizing and quantifying 5-demethylnobiletin production. PMID:23885986

  10. Development of sandwich dot-ELISA for specific detection of Ochratoxin A and its application on to contaminated cereal grains originating from India

    PubMed Central

    Venkataramana, M.; Rashmi, R.; Uppalapati, Siva R.; Chandranayaka, S.; Balakrishna, K.; Radhika, M.; Gupta, Vijai K.; Batra, H. V.

    2015-01-01

    In the present study, generation and characterization of a highly specific monoclonal antibody (mAb) against Ochratoxin A (OTA) was undertaken. The generated mAb was further used to develop a simple, fast, and sensitive sandwich dot-ELISA (s-dot ELISA) method for detection of OTA from contaminated food grain samples. The limit of detection (LOD) of the developed enzyme-linked immunosorbent assay (ELISA) method was determined as 5.0 ng/mL of OTA. Developed method was more specific toward OTA and no cross reactivity was observed with the other tested mycotoxins such as deoxynivalenol, fumonisin B1, or aflatoxin B1. To assess the utility and reliability of the developed method, several field samples of maize, wheat and rice (n = 195) collected from different geographical regions of southern Karnataka region of India were evaluated for the OTA occurrence. Seventy two out of 195 samples (19 maize, 38 wheat, and 15 rice) were found to be contaminated by OTA by s-dot ELISA. The assay results were further co-evaluated with conventional analytical high-performance liquid chromatography (HPLC) method. Results of the s-dot ELISA are in concordance with HPLC except for three samples that were negative for OTA presence by s-dot ELISA but found positive by HPLC. Although positive by HPLC, the amount of OTA in the three samples was found to be lesser than the accepted levels (>5 μg/kg) of OTA presence in cereals. Therefore, in conclusion, the developed s-dot ELISA is a better alternative for routine cereal based food and feed analysis in diagnostic labs to check the presence of OTA over existing conventional culture based, tedious analytical methods. PMID:26074899

  11. Simultaneous HPLC determination of flavonoids and phenolic acids profile in Pêra-Rio orange juice.

    PubMed

    Mesquita, E; Monteiro, M

    2018-04-01

    The aim of this study was to develop and validate an HPLC-DAD method to evaluate the phenolic compounds profile of organic and conventional Pêra-Rio orange juice. The proposed method was validated for 10 flavonoids and 6 phenolic acids. A wide linear range (0.01-223.4μg·g -1 ), good accuracy (79.5-129.2%) and precision (CV≤3.8%), low limits of detection (1-22ng·g -1 ) and quantification (0.7-7.4μg), and overall ruggedness were attained. Good recovery was achieved for all phenolic compounds after extraction and cleanup. The method was applied to organic and conventional Pêra-Rio orange juices from beginning, middle and end of the 2016 harvest. Flavones rutin, nobiletin and tangeretin, and flavanones hesperidin, narirutin and eriocitrin were identified and quantified in all organic and conventional juices. Identity was confirmed by mass spectrometry. Nineteen non-identified phenolic compounds were quantified based on DAD spectra characteristic of the chemical class: 7 cinnamic acid derivatives, 6 flavanones and 6 flavones. The phenolic compounds profile of Pêra-Rio orange juices changed during the harvest; levels increased in organic orange juices, and decreased or were about the same in conventional orange juices. Phenolic compounds levels were higher in organic (0.5-1143.7mg·100g -1 ) than in conventional orange juices (0.5-689.7mg·100g -1 ). PCA differentiated organic from conventional FS and NFC juices, and conventional FCOJ from conventional FS and NFC juices, thus differentiating cultivation and processing. Copyright © 2017. Published by Elsevier Ltd.

  12. Microwave-assisted extraction with water for fast extraction and simultaneous RP-HPLC determination of phenolic acids in radix Salviae Miltiorrhizae.

    PubMed

    Fang, Xinsheng; Wang, Jianhua; Zhou, Hongying; Jiang, Xingkai; Zhu, Lixiang; Gao, Xin

    2009-07-01

    An optimized microwave-assisted extraction method using water (MAE-W) as the extractant and an efficient HPLC analysis method were first developed for the fast extraction and simultaneous determination of D(+)-(3,4-dihydroxyphenyl) lactic acid (Dla), salvianolic acid B (SaB), and lithospermic acid (La) in radix Salviae Miltiorrhizae. The key parameters of MAE-W were optimized. It was found that the degradation of SaB was inhibited when using the optimized MAE-W and the stable content of Dla, La, and SaB in danshen was obtained. Furthermore, compared to the conventional extraction methods, the proposed MAE-W is a more rapid method with higher yield and lower solvent consumption with a reproducibility (RSD <6%). In addition, using water as extractant is safe and helpful for environment protection, which could be referred to as green extraction. The separation and quantitative determination of the three compounds was carried out by a developed reverse-phase high-performance liquid chromatographic (RP-HPLC) method with UV detection. Highly efficient separation was obtained using gradient solvent system. The optimized HPLC analysis method was validated to have specificity, linearity, precision, and accuracy. The results indicated that MAE-W followed by HPLC-UV determination is an appropriate alternative to previously proposed method for quality control of radix Salviae Miltiorrhizae.

  13. Comprehensive characterizations of nanoparticle biodistribution following systemic injection in mice

    NASA Astrophysics Data System (ADS)

    Liao, Wei-Yin; Li, Hui-Jing; Chang, Ming-Yao; Tang, Alan C. L.; Hoffman, Allan S.; Hsieh, Patrick C. H.

    2013-10-01

    Various nanoparticle (NP) properties such as shape and surface charge have been studied in an attempt to enhance the efficacy of NPs in biomedical applications. When trying to undermine the precise biodistribution of NPs within the target organs, the analytical method becomes the determining factor in measuring the precise quantity of distributed NPs. High performance liquid chromatography (HPLC) represents a more powerful tool in quantifying NP biodistribution compared to conventional analytical methods such as an in vivo imaging system (IVIS). This, in part, is due to better curve linearity offered by HPLC than IVIS. Furthermore, HPLC enables us to fully analyze each gram of NPs present in the organs without compromising the signals and the depth-related sensitivity as is the case in IVIS measurements. In addition, we found that changing physiological conditions improved large NP (200-500 nm) distribution in brain tissue. These results reveal the importance of selecting analytic tools and physiological environment when characterizing NP biodistribution for future nanoscale toxicology, therapeutics and diagnostics.Various nanoparticle (NP) properties such as shape and surface charge have been studied in an attempt to enhance the efficacy of NPs in biomedical applications. When trying to undermine the precise biodistribution of NPs within the target organs, the analytical method becomes the determining factor in measuring the precise quantity of distributed NPs. High performance liquid chromatography (HPLC) represents a more powerful tool in quantifying NP biodistribution compared to conventional analytical methods such as an in vivo imaging system (IVIS). This, in part, is due to better curve linearity offered by HPLC than IVIS. Furthermore, HPLC enables us to fully analyze each gram of NPs present in the organs without compromising the signals and the depth-related sensitivity as is the case in IVIS measurements. In addition, we found that changing physiological conditions improved large NP (200-500 nm) distribution in brain tissue. These results reveal the importance of selecting analytic tools and physiological environment when characterizing NP biodistribution for future nanoscale toxicology, therapeutics and diagnostics. Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr03954d

  14. Chip-based nanoflow high performance liquid chromatography coupled to mass spectrometry for profiling of soybean flavonoids.

    PubMed

    Chang, Yuwei; Zhao, Chunxia; Wu, Zeming; Zhou, Jia; Zhao, Sumin; Lu, Xin; Xu, Guowang

    2012-08-01

    In this work a chip-based nano HPLC coupled MS (HPLC-chip/MS) method with a simple sample preparation procedure was developed for the flavonoid profiling of soybean. The analytical properties of the method including the linearity (R(2) , 0.992-0.995), reproducibility (RSD, 1.50-7.66%), intraday precision (RSD, 1.41-5.14%) and interday precision (RSD, 2.76-16.90%) were satisfactory. Compared with the conventional HPLC/MS method, a fast extraction and analysis procedure was applied and more flavonoids were detected in a single run. Additionally, 13 flavonoids in soybean seed were identified for the first time. The method was then applied to the profiling of six varieties of soybean sowed at the same place. A clear discrimination was observed among different cultivars, three isoflavones, accounting for nearly 80% of total flavonoid contents, were found increased in the spring soybeans compared with the summer cultivars. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Characterization of nutraceuticals and functional foods by innovative HPLC methods.

    PubMed

    Corradini, Claudio; Galanti, Roberta; Nicoletti, Isabella

    2002-04-01

    In recent years there is a growing interest in food and food ingredient which may provide health benefits. Food as well as food ingredients containing health-preserving components, are not considered conventional food, but can be defined as functional food. To characterise such foods, as well as nutraceuticals specific, high sensitive and reproducible analytical methodologies are needed. In light of this importance we set out to develop innovative HPLC methods employing reversed phase narrow bore column and high-performance anion-exchange chromatographic methods coupled with pulsed amperometric detection (HPAEC-PAD), which are specific for carbohydrate analysis. The developed methods were applied for the separation and quantification of citrus flavonoids and to characterize fructooligosaccharide (FOS) and fructans added to functional foods and nutraceuticals.

  16. Off-line real-time FTIR analysis of a process step in imipenem production

    NASA Astrophysics Data System (ADS)

    Boaz, Jhansi R.; Thomas, Scott M.; Meyerhoffer, Steven M.; Staskiewicz, Steven J.; Lynch, Joseph E.; Egan, Richard S.; Ellison, Dean K.

    1992-08-01

    We have developed an FT-IR method, using a Spectra-Tech Monit-IR 400 systems, to monitor off-line the completion of a reaction in real-time. The reaction is moisture-sensitive and analysis by more conventional methods (normal-phase HPLC) is difficult to reproduce. The FT-IR method is based on the shift of a diazo band when a conjugated beta-diketone is transformed into a silyl enol ether during the reaction. The reaction mixture is examined directly by IR and does not require sample workup. Data acquisition time is less than one minute. The method has been validated for specificity, precision and accuracy. The results obtained by the FT-IR method for known mixtures and in-process samples compare favorably with those from a normal-phase HPLC method.

  17. Fractionation of secondary metabolites of orange (Citrus sinensis L.) leaves by fast centrifugal partition chromatography

    USDA-ARS?s Scientific Manuscript database

    Conventional HPLC provides ready detection of the major phenolic compounds in methanol extracts of orange leaves, yet conventional HPLC also shows the presence of many more compounds, to an extent where extensive peak overlap prevents distinct peak detection and reliable quantitation. A more complet...

  18. Novel HPLC Analysis of Hydrocortisone in Conventional and Controlled-Release Pharmaceutical Preparations.

    PubMed

    Adi-Dako, Ofosua; Oppong Bekoe, Samuel; Ofori-Kwakye, Kwabena; Appiah, Enoch; Peprah, Paul

    2017-01-01

    An isocratic sensitive and precise reverse phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the determination and quantification of hydrocortisone in controlled-release and conventional (tablets and injections) pharmaceutical preparations. Chromatographic separation was achieved on an ODS (C18), 5  μ m, 4.6 × 150 mm, with an isocratic elution using a freshly prepared mobile phase of composition methanol : water : acetic acid (60 : 30 : 10, v/v/v) at a flow rate of 1.0 ml/min. The detection of the drug was successfully achieved at a wavelength of 254 nm. The retention time obtained for the drug was 2.26 min. The proposed method produced linear detectable responses in the concentration range of 0.02 to 0.4 mg/ml of hydrocortisone. High recoveries of 98-101% were attained at concentration levels of 80%, 100%, and 120%. The intraday and interday precision (RSD) were 0.19-0.55% and 0.33-0.71%, respectively. A comparison of hydrocortisone analyses data from the developed method and the official USP method showed no significant difference ( p > 0.05) at a 95% confidence interval. The method was successfully applied to the determination and quantification of hydrocortisone in six controlled-release and fifteen conventional release pharmaceutical preparations.

  19. Novel HPLC Analysis of Hydrocortisone in Conventional and Controlled-Release Pharmaceutical Preparations

    PubMed Central

    Oppong Bekoe, Samuel; Appiah, Enoch; Peprah, Paul

    2017-01-01

    An isocratic sensitive and precise reverse phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the determination and quantification of hydrocortisone in controlled-release and conventional (tablets and injections) pharmaceutical preparations. Chromatographic separation was achieved on an ODS (C18), 5 μm, 4.6 × 150 mm, with an isocratic elution using a freshly prepared mobile phase of composition methanol : water : acetic acid (60 : 30 : 10, v/v/v) at a flow rate of 1.0 ml/min. The detection of the drug was successfully achieved at a wavelength of 254 nm. The retention time obtained for the drug was 2.26 min. The proposed method produced linear detectable responses in the concentration range of 0.02 to 0.4 mg/ml of hydrocortisone. High recoveries of 98–101% were attained at concentration levels of 80%, 100%, and 120%. The intraday and interday precision (RSD) were 0.19–0.55% and 0.33–0.71%, respectively. A comparison of hydrocortisone analyses data from the developed method and the official USP method showed no significant difference (p > 0.05) at a 95% confidence interval. The method was successfully applied to the determination and quantification of hydrocortisone in six controlled-release and fifteen conventional release pharmaceutical preparations. PMID:28660092

  20. Analysis and quality control of carbohydrates in therapeutic proteins with fluorescence HPLC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Kun; Huang, Jian; Center for Informational Biology, University of Electronic Science and Technology of China, Chengdu 610054

    Conbercept is an Fc fusion protein with very complicated carbohydrate profiles which must be carefully monitored through manufacturing process. Here, we introduce an optimized fluorescence derivatization high-performance liquid chromatographic method for glycan mapping in conbercept. Compared with conventional glycan analysis method, this method has much better resolution and higher reproducibility making it excellent for product quality control.

  1. Ultratraces of carotenes in tomato purées: HPLC-TLS study

    NASA Astrophysics Data System (ADS)

    Luterotti, S.; Marković, K.; Franko, M.; Bicanic, D.; Vahčić, N.; Doka, O.

    2003-01-01

    The present study was designed to provide information about (i) the profile of carotene pigments and (ii) trace quantities of lycopene and β-carotene left in tomato purées. The ultrasensitive method comprising HPLC and thermal lens spectrometric (TLS) detection enabled us to detect as low as 0.3 and 1.1 ng ml-1 lycopene and β-carotene in purée extracts, respectively. Total concentration of β-carotene and lycopene (varying from 3 to 170 ng g-1) in the examined tomato purées may serve as an indicator of the carotene-specific antioxidative capacity of these products. Although conventional spectrophotometry can be used to rapidly assess the quality of products derived from tomatoes, a highly sensitive and selective method such as HPLC-TLS is needed for reliable analyses of samples such as, for example, those subjected to inappropriate storage and/or handling.

  2. Differentiating Organic and Conventional Sage by Chromatographic and Mass Spectrometry Flow-Injection Fingerprints Combined with Principal Component Analysis

    PubMed Central

    Gao, Boyan; Lu, Yingjian; Sheng, Yi; Chen, Pei; Yu, Liangli (Lucy)

    2013-01-01

    High performance liquid chromatography (HPLC) and flow injection electrospray ionization with ion trap mass spectrometry (FIMS) fingerprints combined with the principal component analysis (PCA) were examined for their potential in differentiating commercial organic and conventional sage samples. The individual components in the sage samples were also characterized with an ultra-performance liquid chromatography with a quadrupole-time of flight mass spectrometer (UPLC Q-TOF MS). The results suggested that both HPLC and FIMS fingerprints combined with PCA could differentiate organic and conventional sage samples effectively. FIMS may serve as a quick test capable of distinguishing organic and conventional sages in 1 min, and could potentially be developed for high-throughput applications; whereas HPLC fingerprints could provide more chemical composition information with a longer analytical time. PMID:23464755

  3. Optimization of microwave-assisted extraction for the characterization of olive leaf phenolic compounds by using HPLC-ESI-TOF-MS/IT-MS(2).

    PubMed

    Taamalli, Amani; Arráez-Román, David; Ibañez, Elena; Zarrouk, Mokhtar; Segura-Carretero, Antonio; Fernández-Gutiérrez, Alberto

    2012-01-25

    In the present work, a simple and rapid method for the extraction of phenolic compounds from olive leaves, using microwave-assisted extraction (MAE) technique, has been developed. The experimental variables that affect the MAE process, such as the solvent type and composition, microwave temperature, and extraction time, were optimized using a univariate method. The obtained extracts were analyzed by using high-performance liquid chromatography (HPLC) coupled to electrospray time-of-flight mass spectrometry (ESI-TOF-MS) and electrospray ion trap tandem mass spectrometry (ESI-IT-MS(2)) to prove the MAE extraction efficiency. The optimal MAE conditions were methanol:water (80:20, v/v) as extracting solvent, at a temperature equal to 80 °C for 6 min. Under these conditions, several phenolic compounds could be characterized by HPLC-ESI-MS/MS(2). As compared to the conventional method, MAE can be used as an alternative extraction method for the characterization of phenolic compounds from olive leaves due to its efficiency and speed.

  4. Microwave-assisted Derivatization of Fatty Acids for Its Measurement in Milk Using High-Performance Liquid Chromatography.

    PubMed

    Shrestha, Rojeet; Miura, Yusuke; Hirano, Ken-Ichi; Chen, Zhen; Okabe, Hiroaki; Chiba, Hitoshi; Hui, Shu-Ping

    2018-01-01

    Fatty acid (FA) profiling of milk has important applications in human health and nutrition. Conventional methods for the saponification and derivatization of FA are time-consuming and laborious. We aimed to develop a simple, rapid, and economical method for the determination of FA in milk. We applied a beneficial approach of microwave-assisted saponification (MAS) of milk fats and microwave-assisted derivatization (MAD) of FA to its hydrazides, integrated with HPLC-based analysis. The optimal conditions for MAS and MAD were determined. Microwave irradiation significantly reduced the sample preparation time from 80 min in the conventional method to less than 3 min. We used three internal standards for the measurement of short-, medium- and long-chain FA. The proposed method showed satisfactory analytical sensitivity, recovery and reproducibility. There was a significant correlation in the milk FA concentrations between the proposed and conventional methods. Being quick, economic, and convenient, the proposed method for the milk FA measurement can be substitute for the convention method.

  5. Analytical Eco-Scale for Assessing the Greenness of a Developed RP-HPLC Method Used for Simultaneous Analysis of Combined Antihypertensive Medications.

    PubMed

    Mohamed, Heba M; Lamie, Nesrine T

    2016-09-01

    In the past few decades the analytical community has been focused on eliminating or reducing the usage of hazardous chemicals and solvents, in different analytical methodologies, that have been ascertained to be extremely dangerous to human health and environment. In this context, environmentally friendly, green, or clean practices have been implemented in different research areas. This study presents a greener alternative of conventional RP-HPLC methods for the simultaneous determination and quantitative analysis of a pharmaceutical ternary mixture composed of telmisartan, hydrochlorothiazide, and amlodipine besylate, using an ecofriendly mobile phase and short run time with the least amount of waste production. This solvent-replacement approach was feasible without compromising method performance criteria, such as separation efficiency, peak symmetry, and chromatographic retention. The greenness profile of the proposed method was assessed and compared with reported conventional methods using the analytical Eco-Scale as an assessment tool. The proposed method was found to be greener in terms of usage of hazardous chemicals and solvents, energy consumption, and production of waste. The proposed method can be safely used for the routine analysis of the studied pharmaceutical ternary mixture with a minimal detrimental impact on human health and the environment.

  6. A modified HPLC method improves the simultaneous determination of plasma kynurenine and tryptophan concentrations in patients following maintenance hemodialysis

    PubMed Central

    XIAO, CHENGGEN; CHEN, YUANHAN; LIANG, XINLING; XIE, ZHEN; ZHANG, MIN; LI, RUIZHAO; LI, ZHILIAN; FU, XIA; YU, XIYONG; SHI, WEI

    2014-01-01

    The ratio between plasma kynurenine (Kyn) and tryptophan (Trp) serves as a marker of indoleamine 2,3-dioxygenase, a critical immunomodulatory molecule. Simultaneous detection of the two markers may be performed using high-pressure liquid chromatography (HPLC). However, for uremic patients, the conventional detection method may be affected by a range of accumulated toxins. The current study aimed to establish a method for the simultaneous measurement of Kyn and Trp in patients following maintenance hemodialysis via HPLC-ultraviolet detection. The procedure involved the use of a SinoChrom ODS-BP C18 column (4.6×150 mm; inner diameter, 4.5 μm) and a mobile phase of 15 mmol/l sodium acetate acetic acid solution (containing 5% acetonitrile, pH 4.8). The modified method was verified using plasma samples from 10 healthy controls and 91 maintenance hemodialysis patients. The results demonstrated that the modified method was successful in simultaneously detecting the concentrations of Trp and Kyn in the healthy controls and maintenance hemodialysis patients. The method is simple, fast, accurate and suitable for clinical and research purposes in maintenance hemodialysis patients. PMID:24669249

  7. Ultra high performance liquid chromatography with ion-trap TOF-MS for the fast characterization of flavonoids in Citrus bergamia juice.

    PubMed

    Sommella, Eduardo; Pepe, Giacomo; Pagano, Francesco; Tenore, Gian Carlo; Dugo, Paola; Manfra, Michele; Campiglia, Pietro

    2013-10-01

    We have developed a fast ultra HPLC with ion-trap TOF-MS method for the analysis of flavonoids in Citrus bergamia juice. With respect to the typical methods for the analysis of these matrices based on conventional HPLC techniques, a tenfold faster separation was attained. The use of a core-shell particle column ensured high resolution within the fast analysis time of only 5 min. Unambiguous determination of flavonoid identity was obtained by the employment of a hybrid ion-trap TOF mass spectrometer with high mass accuracy (average error 1.69 ppm). The system showed good retention time and peak area repeatability, with maximum RSD% values of 0.36 and 3.86, respectively, as well as good linearity (R(2) ≥ 0.99). Our results show that ultra HPLC can be a useful tool for ultra fast qualitative/quantitative analysis of flavonoid compounds in citrus fruit juices. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Simultaneous extraction, identification and quantification of phenolic compounds in Eclipta prostrata using microwave-assisted extraction combined with HPLC-DAD-ESI-MS/MS.

    PubMed

    Fang, Xinsheng; Wang, Jianhua; Hao, Jifu; Li, Xueke; Guo, Ning

    2015-12-01

    A simple and rapid method was developed using microwave-assisted extraction (MAE) combined with HPLC-DAD-ESI-MS/MS for the simultaneous extraction, identification, and quantification of phenolic compounds in Eclipta prostrata, a common herb and vegetable in China. The optimized parameters of MAE were: employing 50% ethanol as solvent, microwave power 400 W, temperature 70 °C, ratio of liquid/solid 30 mL/g and extraction time 2 min. Compared to conventional extraction methods, the optimized MAE can avoid the degradation of the phenolic compounds and simultaneously obtained the highest yields of all components faster with less consumption of solvent and energy. Six phenolic acids, six flavonoid glycosides and one coumarin were firstly identified. The phenolic compounds were quantified by HPLC-DAD with good linearity, precision, and accuracy. The extract obtained by MAE showed significant antioxidant activity. The proposed method provides a valuable and green analytical methodology for the investigation of phenolic components in natural plants. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Unambiguous detection of astaxanthin and astaxanthin fatty acid esters in krill (Euphausia superba Dana).

    PubMed

    Grynbaum, Marc David; Hentschel, Petra; Putzbach, Karsten; Rehbein, Jens; Krucker, Manfred; Nicholson, Graeme; Albert, Klaus

    2005-09-01

    HPLC atmospheric pressure chemical ionization (APCI)/MS, GC MS, HPLC diode array detection (DAD), and NMR were used for the identification of astaxanthin and astaxanthin fatty acid esters in krill (Euphausia superba Dana). Matrix solid phase dispersion was applied for the extraction of the carotenoids. This gentle and expeditious extraction technique for solid and viscous samples leads to distinct higher enrichment rates than the conventional liquid-liquid extraction. The chromatographic separation was achieved employing a C30 RP column that allows the separation of shape-constrained geometrical isomers. A methanol/tert-butylmethyl ether/water gradient was applied. (all-E) Astaxanthin and the geometrical isomers were identified by HPLC APCI/MS, by coelution with isomerized authentical standard, by UV spectroscopy (DAD), and three isomers were unambiguously assigned by microcoil NMR spectroscopy. In this method, microcoils are transversally aligned to the magnetic field and have an increased sensitivity compared to the conventional double-saddle Helmholtz coils, thus enabling the measurement on small samples. The carotenol fatty acid esters were saponified enzymatically with Lipase type VII from Candida rugosa. The fatty acids were detected by GC MS after transesterification, but also without previous derivatization by HPLC APCI/MS. C14:0, C16:0, C16:1, C18:1, C20:0, C20:5, and C22:6 were found in astaxanthin monoesters and in astaxanthin diesters. (all-E) Astaxanthin was identified as the main isomer in six fatty acid ester fractions by NMR. Quantitation was carried out by the method of internal standard. (13-cis) Astaxanthin (70 microg/g), 542 microg/g (all-E) astaxanthin, 36 microg/g unidentified astaxanthin isomer, 62 microg/g (9-cis) astaxanthin, and 7842 microg/g astaxanthin fatty acid esters were found.

  10. Reversed-phase HPLC analysis of levetiracetam in tablets using monolithic and conventional C18 silica columns.

    PubMed

    Can, Nafiz O; Arli, Goksel

    2010-01-01

    Development and validation of an RP-HPLC method for determination of levetiracetam in pharmaceutical tablets is described. The separation and quantification of levetiracetam and caffeine (internal standard) were performed using a single analytical procedure with two different types of stationary phases, conventional Phenomenex Gemini C18 (100 x 4.6 mm, 5 microm) and Merck Chromolith Performance RP18e (100 x 4.6 mm, macropore size 2 mm, micropore size 13 nm) monolithic silica. Five-microliter aliquots of samples were injected into the system and eluted using water-acetonitrile (90 + 10, v/v) mobile phase pumped at the rate of 1 mL/min. The analyte peaks were detected at 200 nm using a diode array detector with adequate resolution. Validation studies were performed using the method recommended by the International Conference on Harmonization, the U.S. Pharmacopeia, and AOAC INTERNATIONAL, which includes accuracy, precision, range, limits, robustness, and system suitability parameters. Levetiracetam and caffeine were detected in about 7 min using the conventional column, whereas less than 5 min was required when the monolithic column was used. Calibration plots had r values close to unity in the range of 0.8-8.0 microg/mL. Assay of levetiracetam in a tablet formulation was demonstrated as an application to real samples.

  11. Development of an Analytic Method for Sulfur Compounds in Aged Garlic Extract with the Use of a Postcolumn High Performance Liquid Chromatography Method with Sulfur-Specific Detection.

    PubMed

    Matsutomo, Toshiaki; Kodera, Yukihiro

    2016-02-01

    Garlic and its processed preparations contain numerous sulfur compounds that are difficult to analyze in a single run using HPLC. The aim of this study was to develop a rapid and convenient sulfur-specific HPLC method to analyze sulfur compounds in aged garlic extract (AGE). We modified a conventional postcolumn HPLC method by employing a hexaiodoplatinate reagent. Identification and structural analysis of sulfur compounds were conducted by LC-mass spectrometry (LC-MS) and nuclear magnetic resonance. The production mechanisms of cis-S-1-propenylcysteine (cis-S1PC) and S-allylmercaptocysteine (SAMC) were examined by model reactions. Our method has the following advantages: less interference from nonsulfur compounds, high sensitivity, good correlation coefficients (r > 0.98), and high resolution that can separate >20 sulfur compounds, including several isomers, in garlic preparations in a single run. This method was adapted for LC-MS analysis. We identified cis-S1PC and γ-glutamyl-S-allyl-mercaptocysteine in AGE. The results of model reactions suggest that cis-S1PC is produced from trans-S1PC through an isomerization reaction and that SAMC is produced by a reaction involving S-allylcysteine/S1PC and diallyldisulfide during the aging period. We developed a rapid postcolumn HPLC method for both qualitative and quantitative analyses of sulfur compounds, and this method helped elucidate a potential mechanism of cis-S1PC and SAMC action in AGE. © 2016 American Society for Nutrition.

  12. Cloud point extraction of Δ9-tetrahydrocannabinol from cannabis resin.

    PubMed

    Ameur, S; Haddou, B; Derriche, Z; Canselier, J P; Gourdon, C

    2013-04-01

    A cloud point extraction coupled with high performance liquid chromatography (HPLC/UV) method was developed for the determination of Δ(9)-tetrahydrocannabinol (THC) in micellar phase. The nonionic surfactant "Dowfax 20B102" was used to extract and pre-concentrate THC from cannabis resin, prior to its determination with a HPLC-UV system (diode array detector) with isocratic elution. The parameters and variables affecting the extraction were investigated. Under optimum conditions (1 wt.% Dowfax 20B102, 1 wt.% Na2SO4, T = 318 K, t = 30 min), this method yielded a quite satisfactory recovery rate (~81 %). The limit of detection was 0.04 μg mL(-1), and the relative standard deviation was less than 2 %. Compared with conventional solid-liquid extraction, this new method avoids the use of volatile organic solvents, therefore is environmentally safer.

  13. Development and validation of RP HPLC method to determine nandrolone phenylpropionate in different pharmaceutical formulations.

    PubMed

    Mukherjee, Jayanti; Das, Ayan; Chakrabarty, Uday Sankar; Sahoo, Bijay Kumar; Dey, Goutam; Choudhury, Hira; Pal, Tapan Kumar

    2011-01-01

    This study describes development and subsequent validation of a reversed phase high performance liquid chromatographic (RP-HPLC) method for the estimation of nandrolone phenylpropionate, an anabolic steroid, in bulk drug, in conventional parenteral dosage formulation and in prepared nanoparticle dosage form. The chromatographic system consisted of a Luna Phenomenex, CN (250 mm x 4.6 mm, 5 microm) column, an isocratic mobile phase comprising 10 mM phosphate buffer and acetonitrile (50:50, v/v) and UV detection at 240 nm. Nandrolone phenylpropionate was eluted about 6.3 min with no interfering peaks of excipients used for the preparation of dosage forms. The method was linear over the range from 0.050 to 25 microg/mL in raw drug (r2 = 0.9994). The intra-day and inter-day precision values were in the range of 0.219-0.609% and 0.441-0.875%, respectively. Limits of detection and quantitation were 0.010 microg/mL and 0.050 microg/mL, respectively. The results were validated according to International Conference on Harmonization (ICH) guidelines in parenteral and prepared nanoparticle formulation. The validated HPLC method is simple, sensitive, precise, accurate and reproducible.

  14. Chiral ligand exchange high-speed countercurrent chromatography: mechanism, application and comparison with conventional liquid chromatography in enantioseparation of aromatic α-hydroxyl acids

    PubMed Central

    Tong, Shengqiang; Shen, Mangmang; Cheng, Dongping; Ito, Yoichiro; Yan, Jizhong

    2014-01-01

    This work concentrates on the separation mechanism and application of chiral ligand exchange high-speed countercurrent chromatography (HSCCC) in enantioseparations, and comparison with traditional chiral ligand exchange high performance liquid chromatography (HPLC). The enantioseparation of ten aromatic α-hydroxyl acids were performed by these two chromatographic methods. Results showed that five of the racemates were successfully enantioseparated by HSCCC while only three of the racemates could be enantioseparated by HPLC using a suitable chiral ligand mobile phase additive. For HSCCC, the two-phase solvent system was composed of butanol-water (1:1, v/v), to which N-n-dodecyl-L-proline was added in the organic phase as chiral ligand and cupric acetate was added in the aqueous phase as a transition metal ion. Various operation parameters in HSCCC were optimized by enantioselective liquid-liquid extraction. Based on the results of the present studies the separation mechanism for HSCCC was proposed. For HPLC, the optimized mobile phase composed of aqueous solution containing 6 mmol L−1 L-phenylalanine and 3 mmol L−1 cupric sulfate and methanol was used for enantioseparation. Among three ligands tested on a conventional reverse stationary phase column, only one was found to be effective. In the present studies HSCCC presented unique advantages due to its high versatility of two-phase solvent systems and it could be used as an alternative method for enantioseparations. PMID:25087742

  15. Analysis of anthocyanins in commercial fruit juices by using nano-liquid chromatography-electrospray-mass spectrometry and high-performance liquid chromatography with UV-vis detector.

    PubMed

    Fanali, Chiara; Dugo, Laura; D'Orazio, Giovanni; Lirangi, Melania; Dachà, Marina; Dugo, Paola; Mondello, Luigi

    2011-01-01

    Nano-LC and conventional HPLC techniques were applied for the analysis of anthocyanins present in commercial fruit juices using a capillary column of 100 μm id and a 2.1 mm id narrow-bore C(18) column. Analytes were detected by UV-Vis at 518 nm and ESI-ion trap MS with HPLC and nano-LC, respectively. Commercial blueberry juice (14 anthocyanins detected) was used to optimize chromatographic separation of analytes and other analysis parameters. Qualitative identification of anthocyanins was performed by comparing the recorded mass spectral data with those of published papers. The use of the same mobile phase composition in both techniques revealed that the miniaturized method exhibited shorter analysis time and higher sensitivity than narrow-bore chromatography. Good intra-day and day-to-day precision of retention time was obtained in both methods with values of RSD less than 3.4 and 0.8% for nano-LC and HPLC, respectively. Quantitative analysis was performed by external standard curve calibration of cyanidin-3-O-glucoside standard. Calibration curves were linear in the concentration ranges studied, 0.1-50 and 6-50 μg/mL for HPLC-UV/Vis and nano-LC-MS, respectively. LOD and LOQ values were good for both methods. In addition to commercial blueberry juice, qualitative and quantitative analysis of other juices (e.g. raspberry, sweet cherry and pomegranate) was performed. The optimized nano-LC-MS method allowed an easy and selective identification and quantification of anthocyanins in commercial fruit juices; it offered good results, shorter analysis time and reduced mobile phase volume with respect to narrow-bore HPLC. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Microfluidic chip based nano liquid chromatography coupled to tandem mass spectrometry for the determination of abused drugs and metabolites in human hair.

    PubMed

    Zhu, Kevin Y; Leung, K Wing; Ting, Annie K L; Wong, Zack C F; Ng, Winki Y Y; Choi, Roy C Y; Dong, Tina T X; Wang, Tiejie; Lau, David T W; Tsim, Karl W K

    2012-03-01

    A microfluidic chip based nano-HPLC coupled to tandem mass spectrometry (nano-HPLC-Chip-MS/MS) has been developed for simultaneous measurement of abused drugs and metabolites: cocaine, benzoylecgonine, cocaethylene, norcocaine, morphine, codeine, 6-acetylmorphine, phencyclidine, amphetamine, methamphetamine, MDMA, MDA, MDEA, and methadone in the hair of drug abusers. The microfluidic chip was fabricated by laminating polyimide films and it integrated an enrichment column, an analytical column and a nanospray tip. Drugs were extracted from hairs by sonication, and the chromatographic separation was achieved in 15 min. The drug identification and quantification criteria were fulfilled by the triple quardropule tandem mass spectrometry. The linear regression analysis was calibrated by deuterated internal standards with all of the R(2) at least over 0.993. The limit of detection (LOD) and the limit of quantification (LOQ) were from 0.1 to 0.75 and 0.2 to 1.25 pg/mg, respectively. The validation parameters including selectivity, accuracy, precision, stability, and matrix effect were also evaluated here. In conclusion, the developed sample preparation method coupled with the nano-HPLC-Chip-MS/MS method was able to reveal the presence of drugs in hairs from the drug abusers, with the enhanced sensitivity, compared with the conventional HPLC-MS/MS.

  17. Identification of ionic chloroacetanilide-herbicide metabolites in surface water and groundwater by HPLC/MS using negative ion spray

    USGS Publications Warehouse

    Ferrer, I.; Thurman, E.M.; Barcelo, D.

    1997-01-01

    Solid-phase extraction (SPE) was combined with high-performance liquid chromatography/high-flow pneumatically assisted electrospray mass spectrometry (HPLC/ESP/MS) for the trace analysis of oxanilic and sulfonic acids of acetochlor, alachlor, and metolachlor. The isolation procedure separated the chloroacetanilide metabolites from the parent herbicides during the elution from C18 cartridges using ethyl acetate for parent compounds, followed by methanol for the anionic metabolites. The metabolites were separated chromatographically using reversed-phase HPLC and analyzed by negative-ion MS using electrospray ionization in selected ion mode. Quantitation limits were 0.01 ??g/L for both the oxanilic and sulfonic acids based on a 100-mL water sample. This combination of methods represents an important advance in environmental analysis of chloroacetanilide-herbicide metabolites in surface water and groundwater for two reasons. First, anionic chloroacetanilide metabolites are a major class of degradation products that are readily leached to groundwater in agricultural areas. Second, anionic metabolites, which are not able to be analyzed by conventional methods such as liquid extraction and gas chromatography/mass spectrometry, are effectively analyzed by SPE and high-flow pneumatically assisted electrospray mass spectrometry. This paper reports the first HPLC/MS identification of these metabolites in surface water and groundwater.

  18. Bioanalytical Applications of Fluorescence Line-Narrowing and Non-Line-Narrowing Spectroscopy Interfaced with Capillary Electrophoresis and High-Performance Liquid Chromatography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roberts, Kenneth Paul

    Capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC) are widely used analytical separation techniques with many applications in chemical, biochemical, and biomedical sciences. Conventional analyte identification in these techniques is based on retention/migration times of standards; requiring a high degree of reproducibility, availability of reliable standards, and absence of coelution. From this, several new information-rich detection methods (also known as hyphenated techniques) are being explored that would be capable of providing unambiguous on-line identification of separating analytes in CE and HPLC. As further discussed, a number of such on-line detection methods have shown considerable success, including Raman, nuclear magnetic resonancemore » (NMR), mass spectrometry (MS), and fluorescence line-narrowing spectroscopy (FLNS). In this thesis, the feasibility and potential of combining the highly sensitive and selective laser-based detection method of FLNS with analytical separation techniques are discussed and presented. A summary of previously demonstrated FLNS detection interfaced with chromatography and electrophoresis is given, and recent results from on-line FLNS detection in CE (CE-FLNS), and the new combination of HPLC-FLNS, are shown.« less

  19. Determination of the major constituents in fruit of Arctium lappa L. by matrix solid-phase dispersion extraction coupled with HPLC separation and fluorescence detection.

    PubMed

    Liu, He; Zhang, Yupu; Sun, Yantao; Wang, Xue; Zhai, Yujuan; Sun, Ye; Sun, Shuo; Yu, Aimin; Zhang, Hanqi; Wang, Yinghua

    2010-10-15

    The arctiin and arctigenin in the fruit of Arctium lappa L. were extracted by matrix solid-phase dispersion (MSPD) and determined by high-performance liquid chromatography (HPLC) with fluorescence detection. The experimental conditions for the MSPD were optimized. Silica gel was selected as dispersion adsorbent and methanol as elution solvent. The calibration curve showed good relationship (r>0.9998) in the concentration range of 0.010-5.0μgmL(-1) for arctiin and 0.025-7.5μgmL(-1) for arctigenin. The recoveries were between 74.4% and 100%. The proposed method consumed less sample, time and solvent compared with conventional methods, including ultrasonic and Soxhlet extraction. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Determination of thiopurine S-methyltransferase activity by hydrophilic interaction liquid chromatography hyphenated with mass spectrometry.

    PubMed

    Pecher, Daniel; Dokupilová, Svetlana; Zelinková, Zuzana; Peppelenbosch, Maikel; Mikušová, Veronika; Mikuš, Peter

    2017-08-05

    Thiopurine S-methyltransferase (TPMT) plays an important role in the metabolism of thiopurines used in the therapy of inflammatory bowel diseases (IBD). In this work a new progressive method for the determination of TPMT activity in red blood cells lysates was developed. Analysis was carried out by means of hydrophilic interaction liquid chromatography (HILIC) hyphenated with mass spectrometry (MS). In comparison with reversed-phase high-performance liquid chromatography (RP-HPLC), that has been typically applied in determination of TPMT activity, the HILIC significantly improved the analytical signal provided by MS, shortened analysis time, and improved chromatographic resolution. The HILIC-HPLC-MS method was optimized and validated, providing favorable parameters of detection and quantitation limits (5.5 and 16.5pmol/mL, respectively), linearity (coefficient of determination 0.9999 in the range of 0.01-1.0nmol/mL), recovery and precision (93.25-100.37% with RSD 1.06-1.32% in the whole concentration range of QC samples). Moreover, in contrast to the conventional RP-HPLC-UV approach, the complex phenotype TPMT profiles can be reliably and without interferences monitored using the HILIC-HPLC-MS method. Such advanced monitoring can provide valuable detail information on the thiopurines (e.g. evaluating ratio of methylated and non-methylated 6-mercaptopurine) and, by that, TPMT action in biological systems before and during the therapy of IBD. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Microwave- and ultrasound-assisted extraction of vanillin and its quantification by high-performance liquid chromatography in Vanilla planifolia.

    PubMed

    Sharma, Anuj; Verma, Subash Chandra; Saxena, Nisha; Chadda, Neetu; Singh, Narendra Pratap; Sinha, Arun Kumar

    2006-03-01

    Microwave-assisted extraction (MAE), ultrasound-assisted extraction (UAE) and conventional extraction of vanillin and its quantification by HPLC in pods of Vanilla planifolia is described. A range of nonpolar to polar solvents were used for the extraction of vanillin employing MAE, UAE and conventional methods. Various extraction parameters such as nature of the solvent, solvent volume, time of irradiation, microwave and ultrasound energy inputs were optimized. HPLC was performed on RP ODS column (4.6 mm ID x 250 mm, 5 microm, Waters), a photodiode array detector (Waters 2996) using gradient solvent system of ACN and ortho-phosphoric acid in water (0.001:99.999 v/v) at 25 degrees C. Regression equation revealed a linear relationship (r2 > 0.9998) between the mass of vanillin injected and the peak areas. The detection limit (S/N = 3) and limit of quantification (S/N = 10) were 0.65 and 1.2 microg/g, respectively. Recovery was achieved in the range 98.5-99.6% for vanillin. Maximum yield of vanilla extract (29.81, 29.068 and 14.31% by conventional extraction, MAE and UAE, respectively) was found in a mixture of ethanol/water (40:60 v/v). Dehydrated ethanolic extract showed the highest amount of vanillin (1.8, 1.25 and 0.99% by MAE, conventional extraction and UAE, respectively).

  2. Development of a sensitive high-performance liquid chromatographic method with simple extraction for simultaneous determination of huperzine A and huperzine B in the species containing lycopodium alkaloids.

    PubMed

    Zhang, Yanqing; Xie, Junbo; Chen, Wen-Qian; Zhou, Tian-Yan; Lu, Wei

    2009-01-01

    A sensitive HPLC method with simple extraction was developed for simultaneous determination of huperzine A (HupA) and huperzine B (HupB) in Huperzia serrata, H. crispata, H. miyoshiana, and Lycopodiastrum casuarinoides. In order to avoid conventional multiple-step and time-consuming sample preparation methods, direct reflux extraction with alkaline chloroform was adopted. The quantitative determination was conducted by reversed-phase HPLC with a photodiode array detector set at 308 nm. Separation was performed on a Luna C18 column (250 x 4.6 mm id, 5 microm) with methanol-0.2% aqueous acetic acid (18 + 82, v/v) mobile phase. The method was validated for accuracy, reproducibility, precision, and limits of detection and quantification. Quantification of the two active compounds in the samples was performed by this newly developed method, and the content of HupA and HupB varied substantially among four different species. The satisfactory results indicated that the developed method can readily be utilized for quality control of the species of Huperziaceae and Lycopodiaceae containing the two compounds.

  3. Guanidinium ionic liquid-based surfactants as low cytotoxic extractants: Analytical performance in an in-situ dispersive liquid-liquid microextraction method for determining personal care products.

    PubMed

    Pacheco-Fernández, Idaira; Pino, Verónica; Ayala, Juan H; Afonso, Ana M

    2018-07-20

    The IL-based surfactant octylguanidinium chloride (C 8 Gu-Cl) was designed and synthetized with the purpose of obtaining a less harmful surfactant: containing guanidinium as core cation and a relatively short alkyl chain. Its interfacial and aggregation behavior was evaluated through conductivity and fluorescence measurements, presenting a critical micelle concentration value of 42.5 and 44.6mmolL -1 , respectively. Cytotoxicity studies were carried out with C 8 Gu-Cl and other IL-based and conventional surfactants, specifically the analogue 1-octyl-3-methylimidazolium chloride (C 8 MIm-Cl), and other imidazolium- (C 16 MIm-Br) and pyridinium- (C 16 Py-Cl) based surfactants, together with the conventional cationic CTAB and the conventional anionic SDS. From these studies, C 8 Gu-Cl was the only one to achieve the classification of low cytotoxicity. An in situ dispersive liquid-liquid microextraction (DLLME) method based on transforming the water-soluble C 8 Gu-Cl IL-based surfactant into a water-insoluble IL microdroplet via a simple metathesis reaction was then selected as the extraction/preconcentration method for a group of 6 personal care products (PCPs) present in cosmetic samples. The method was carried out in combination with high-performance liquid chromatography (HPLC) and diode array detection (DAD). The method was properly optimized, requiring the use of only 30μL of C 8 Gu-Cl for 10mL of aqueous sample with a NaCl content of 8% (w/v) to adjust the ionic strength and pH value of 5. The metathesis reaction required the addition of the anion exchange reagent (bis[(trifluoromethyl)sulfonyl]imide - 1:1 molar ratio), followed by vortex and centrifugation, and dilution of the final microdroplet up to 60μL with acetonitrile before the injection in the HPLC-DAD system. The optimum in situ DLLME-HPLC-DAD method takes ∼10min for the extraction step and ∼22min for the chromatographic separation, with analytical features of low detection limits: down to 0.4μgL -1 ; high reproducibility: with RSD values lower than 10% (intra-day) and 16% (inter-day) for a spiked level of 15μgL -1 ; and an average enrichment factor of 89. The requirement of low volumes (30μL) of a low cytotoxic IL-based surfactant allows the method to be considered less harmful than other common analytical microextraction approaches. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Simultaneous quantitation of chloroquine and primaquine by UPLC-DAD and comparison with a HPLC-DAD method.

    PubMed

    Miranda, Tiago A; Silva, Pedro H R; Pianetti, Gerson A; César, Isabela C

    2015-01-28

    Chloroquine and primaquine are the first-line treatment recommended by World Health Organization for malaria caused by Plasmodium vivax. Since the problem of counterfeit or substandard anti-malarials is well established all over the world, the development of rapid and reliable methods for quality control analysis of these drugs is essential. Thus, the aim of this study was to develop and validate a novel UPLC-DAD method for simultaneously quantifying chloroquine and primaquine in tablet formulations. The UPLC separation was carried out using a Hypersil C18 column (50 × 2.1 mm id; 1.9 μm particle size) and a mobile phase composed of acetonitrile (A) and 0.1% aqueous triethylamine, pH 3.0 adjusted with phosphoric acid (B), at a flow rate 0.6 mL/min. Gradient elution was employed. UV detection was performed at 260 nm. UPLC method was fully validated and the results were compared to a conventional HPLC-DAD method for the analysis of chloroquine and primaquine in tablet formulations. UPLC method was shown to be linear (r2 > 0.99), precise (CV < 2.0%), accurate (recovery rates from 98.11 to 99.83%), specific, and robust. No significant differences were observed between the chloroquine and primaquine contents obtained by UPLC and HPLC methods. However, UPLC method promoted faster analyses, better chromatographic performance and lower solvent consumption. The developed UPLC method was shown to be a rapid and suitable technique to quantify chloroquine and primaquine in pharmaceutical preparations and may be successfully employed for quality control analysis.

  5. Determination of synthetic by-products and an intermediate in the colour additives D&C Red Nos 27 and 28 (phloxine B) and their lakes using conventional HPLC.

    PubMed

    Weisz, Adrian; Krantz, Zoe B

    2014-01-01

    Specifications in the US Code of Federal Regulations (CFR) for the colour additives D&C Red No. 27 (R27) and D&C Red No. 28 (R28) limit the levels of the synthetic by-products 2,3,4,5-tetrachloro-6-(3´,5´-dibromo-2´,4´-dihydroxybenzoyl)benzoic acid (SBBA) and "brominated resorcinol" and of the intermediate 3,4,5,6-tetrachlorophthalic acid (TCPA). The present study reports the development and application of a conventional HPLC method for the quantitative determination of these impurities in R27, R28 and their lakes. Because the CFR-listed "brominated resorcinol" refers to a group of synthetic by-products, six variously brominated resorcinols were examined as possible impurities. Due to their rapid decomposition in the presence of the dye, the existence of any brominated resorcinols in R27 and R28 is highly unlikely, and this supposition is supported by the results obtained in this study. SBBA, 2,4,6-tribromoresorcinol (Br3R, the brominated resorcinol most likely to be found as an impurity) and TCPA were quantified by using five-point calibration curves with data points (w/w) that ranged from 0.066% to 0.820% for SBBA, from 0.050% to 0.499% for Br3R, and from 0.061% to 1.410% for TCPA. The HPLC method was applied to the analysis of test portions from batches of R27, R28 and their lakes submitted to the USFDA for certification by domestic and foreign manufacturers.

  6. Detection of basal acetylcholine release in the microdialysis of rat frontal cortex by high-performance liquid chromatography using a horseradish peroxidase-osmium redox polymer electrode with pre-enzyme reactor.

    PubMed

    Kato, T; Liu, J K; Yamamoto, K; Osborne, P G; Niwa, O

    1996-06-28

    To determine the basal acetylcholine level in the dialysate of rat frontal cortex, a horseradish peroxidase-osmium redox polymer-modified glassy carbon electrode (HRP-GCE) was employed instead of the conventional platinum electrode used in high-performance liquid chromatography-electrochemical detection (HPLC-ED). In initial experiments, an oxidizable unknown compound interfered with the detection of basal acetylcholine release on HPLC-HRP-GCE. An immobilized peroxidase-choline oxidase precolumn (pre-reactor) was included in the HPLC system, to eliminate the interference from the unknown compound. This combination could detect less than 10 fmol of standard acetylcholine and basal acetylcholine levels in the dialysate from a conventional concentric design microdialysis probe, without the use of cholinesterase inhibitor, and may facilitate physiological investigation of cholinergic neuronal activity in the central nervous system.

  7. Electrochemistry coupled online to liquid chromatography-mass spectrometry for fast simulation of biotransformation reactions of the insecticide chlorpyrifos.

    PubMed

    Mekonnen, Tessema F; Panne, Ulrich; Koch, Matthias

    2017-05-01

    An automated method is presented for fast simulation of (bio)transformation products (TPs) of the organophosphate insecticide chlorpyrifos (CPF) based on electrochemistry coupled online to liquid chromatography-mass spectrometry (EC-LC-MS). Oxidative TPs were produced by a boron doped diamond (BDD) electrode, separated by reversed phase HPLC and online detected by electrospray ionization-mass spectrometry (ESI-MS). Furthermore, EC oxidative TPs were investigated by HPLC-tandem mass spectrometry (LC-MS/MS) and FT-ICR high resolution mass spectrometry (HRMS) and compared to in vitro assay metabolites (rat and human liver microsomes). Main phase I metabolites of CPF: chlorpyrifos oxon (CPF oxon), trichloropyridinol (TCP), diethylthiophosphate (DETP), diethylphosphate (DEP), desethyl chlorpyrifos (De-CPF), and desethyl chlorpyrifos oxon (De-CPF oxon), were successfully identified by the developed EC-LC-MS method. The EC-LC-MS method showed similar metabolites compared to the in vitro assay with possibilities of determining reactive species. Our results reveal that online EC-(LC)-MS brings an advantage on time of analysis by eliminating sample preparation steps and matrix complexity compared to conventional in vivo or in vitro methods.

  8. Simultaneous determination of eight major steroids from Polyporus umbellatus by high-performance liquid chromatography coupled with mass spectrometry detections.

    PubMed

    Zhao, Ying-yong; Cheng, Xian-long; Zhang, Yongmin; Zhao, Ye; Lin, Rui-chao; Sun, Wen-ji

    2010-02-01

    Polyporus umbellatus is a widely used diuretic herbal medicine. In this study, a high-performance liquid chromatography coupled with atmospheric pressure chemical ionization-mass spectrometric detection (HPLC-APCI-MS) method was developed for qualitative and quantitative analysis of steroids, as well as for the quality control of Polyporus umbellatus. The selectivity, reproducibility and sensitivity were compared with HPLC with photodiode array detection and evaporative light scattering detection (ELSD). Selective ion monitoring in positive mode was used for qualitative and quantitative analysis of eight major components and beta-ecdysterone was used as the internal standard. Limits of detection and quantification fell in the ranges 7-21 and 18-63 ng/mL for the eight analytes with an injection of 10 microL samples, and all calibration curves showed good linear regression (r(2) > 0.9919) within the test range. The quantitative results demonstrated that samples from different localities showed different qualities. Advantages, in comparison with conventional HPLC-diode array detection and HPLC-ELSD, are that reliable identification of target compounds could be achieved by accurate mass measurements along with characteristic retention time, and the great enhancement in selectivity and sensitivity allows identification and quantification of low levels of constituents in complex Polyporus umbellatus matrixes. (c) 2009 John Wiley & Sons, Ltd.

  9. Rapid high performance liquid chromatography method development with high prediction accuracy, using 5cm long narrow bore columns packed with sub-2microm particles and Design Space computer modeling.

    PubMed

    Fekete, Szabolcs; Fekete, Jeno; Molnár, Imre; Ganzler, Katalin

    2009-11-06

    Many different strategies of reversed phase high performance liquid chromatographic (RP-HPLC) method development are used today. This paper describes a strategy for the systematic development of ultrahigh-pressure liquid chromatographic (UHPLC or UPLC) methods using 5cmx2.1mm columns packed with sub-2microm particles and computer simulation (DryLab((R)) package). Data for the accuracy of computer modeling in the Design Space under ultrahigh-pressure conditions are reported. An acceptable accuracy for these predictions of the computer models is presented. This work illustrates a method development strategy, focusing on time reduction up to a factor 3-5, compared to the conventional HPLC method development and exhibits parts of the Design Space elaboration as requested by the FDA and ICH Q8R1. Furthermore this paper demonstrates the accuracy of retention time prediction at elevated pressure (enhanced flow-rate) and shows that the computer-assisted simulation can be applied with sufficient precision for UHPLC applications (p>400bar). Examples of fast and effective method development in pharmaceutical analysis, both for gradient and isocratic separations are presented.

  10. Analysis of lipoprotein profiles of healthy cats by gel-permeation high-performance liquid chromatography

    PubMed Central

    MIZUTANI, Hisashi; SAKO, Toshinori; OKUDA, Hiroko; ARAI, Nobuaki; KURIYAMA, Koji; MORI, Akihiro; YOSHIMURA, Itaru; KOYAMA, Hidekazu

    2016-01-01

    Density gradient ultracentrifugation (DGUC) and gel electrophoresis are conventionally used to obtain lipoprotein profiles of animals. We recently applied high-performance liquid chromatography with a gel permeation column (GP-HPLC) and an on-line dual enzymatic system to dogs for lipoprotein profile analysis. We compared the GP-HPLC with DGUC as a method to obtain a feline lipoprotein profile. The lipoprotein profiles showed large and small peaks, which corresponded to high-density lipoprotein (HDL) and low-density lipoprotein (LDL), respectively, whereas very low-density lipoprotein (VLDL) and chylomicron (CM) were only marginally detected. This profile was very similar to that of dogs reported previously. Healthy cats also had a small amount of cholesterol-rich particles distinct from the normal LDL or HDL profile. There was no difference in lipoprotein profiles between the sexes, but males had a significantly larger LDL particle size (P=0.015). This study shows the feasibility of GP-HPLC for obtaining accurate lipoprotein profiles with small sample volumes and provides valuable reference data for healthy cats that should facilitate diagnoses. PMID:27170431

  11. Use of solid phase extraction (SPE) to evaluate in vitro skin permeation of aescin.

    PubMed

    Montenegro, L; Carbone, C; Giannone, I; Puglisi, G

    2007-05-01

    The aim of this work was to evaluate the feasibility of assessing aescin in vitro permeation through human skin by determining the amount of aescin permeated using conventional HPLC procedures after extraction of skin permeation samples by means of solid phase extraction (SPE). Aescin in vitro skin permeation was assessed from aqueous solutions and gels using both Franz-type diffusion cells and flow-through diffusion cells. The SPE method used was highly accurate (mean accuracy 99.66%), highly reproducible (intra-day and inter-day variations lower than 2.3% and 2.2%, respectively) and aescin recovery from normal saline was greater than 99%. The use of Franz-type diffusion cells did not allow us to determine aescin flux values through excised human skin, therefore aescin skin permeation parameters could be calculated only using flow-through diffusion cells. Plotting the cumulative amount of aescin permeated as a function of time, linear relationships were obtained from both aqueous solution and gel using flow-through diffusion cells. Aescin flux values through excised human skin from aqueous gel were significantly lower than those observed from aqueous solution (p < 0.05). Calculating aescin percutaneous absorption parameters we evidenced that aescin partition coefficient was lower from the aqueous gel with respect to the aqueous solution. Therefore, the SPE method used in this study was suitable to determine aescin in vitro skin permeation parameters from aqueous solutions and gels using a conventional HPLC method for the analysis of the skin permeation samples.

  12. N1, N14-diferuloylspermine as an antioxidative phytochemical contained in leaves of Cardamine fauriei.

    PubMed

    Abe, Keima; Matsuura, Hideyuki; Ukai, Mitsuko; Shimura, Hanako; Koshino, Hiroyuki; Suzuki, Takashi

    2017-10-01

    Most Brassicaceae vegetables are ideal dietary sources of antioxidants beneficial for human health. Cardamine fauriei (Ezo-wasabi in Japanese) is a wild, edible Brassicaceae herb native to Hokkaido, Japan. To clarify the main antioxidative phytochemical, an 80% methanol extraction from the leaves was fractionated with Diaion® HP-20, Sephadex® LH-20, and Sep-Pak® C18 cartridges, and the fraction with strong antioxidant activity depending on DPPH method was purified by HPLC. Based on the analyses using HRESIMS and MS/MS, the compound might be N 1 , N 14 -diferuloylspermine. This rare phenol compound was chemically synthesized, whose data on HPLC, MS and 1 H NMR were compared with those of naturally derived compound from C. fauriei. All results indicated they were the same compound. The radical-scavenging properties of diferuloylspermine were evaluated by ORAC and ESR spin trapping methods, with the diferuloylspermine showing high scavenging activities of the ROO · , O 2 ·- , and HO · radicals as was those of conventional antioxidants.

  13. Comparison of micellar extraction combined with ionic liquid based vortex-assisted liquid-liquid microextraction and modified quick, easy, cheap, effective, rugged, and safe method for the determination of difenoconazole in cowpea.

    PubMed

    Chen, Xiaochu; Bian, Yanli; Liu, Fengmao; Teng, Peipei; Sun, Pan

    2017-10-06

    Two simple sample pretreatment for the determination of difenoconazole in cowpea was developed including micellar extraction combined with ionic liquid based vortex-assisted liquid-liquid microextraction (ME-IL-VALLME) prior to high performance liquid chromatography (HPLC), and modified quick, easy, cheap, effective, rugged, and safe method (QuEChERS) coupled with HPLC-MS/MS. In ME-IL-VALLME method, the target analyte was extracted by surfactant Tween 20 micellar solution, then the supernatant was diluted with 3mL water to decrease the solubility of micellar solution. Subsequently, the vortex-assisted liquid-liquid microextraction (VALLME) procedure was performed in the diluted extraction solution by using the ionic liquid of 1-hexyl-3-methylimidazolium hexafluorophosphate ([HMIM]PF 6 ) as the extraction solvent and Tween 20 as an emulsifier to enhance the dispersion of the water-immiscible ionic liquid into the aqueous phase. Parameters that affect the extraction have been investigated in both methods Under the optimum conditions, the limits of quantitation were 0.10 and 0.05mgkg -1 , respectively. And good linearity was achieved with the correlation coefficient higher than 0.9941. The relative recoveries ranged from 78.6 to 94.8% and 92.0 to 118.0% with the relative standard deviations (RSD) of 7.9-9.6% and 1.2-3.2%, respectively. Both methods were quick, simple and inexpensive. However, the ME-IL-VALLME method provides higher enrichment factor compared with conventional QuEChERS method. The ME-IL-VALLME method has a strong potential for the determination of difenoconazole in complex vegetable matrices with HPLC. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Simultaneous determination of nucleotide sugars with ion-pair reversed-phase HPLC.

    PubMed

    Nakajima, Kazuki; Kitazume, Shinobu; Angata, Takashi; Fujinawa, Reiko; Ohtsubo, Kazuaki; Miyoshi, Eiji; Taniguchi, Naoyuki

    2010-07-01

    Nucleotide sugars are important in determining cell surface glycoprotein glycosylation, which can modulate cellular properties such as growth and arrest. We have developed a conventional HPLC method for simultaneous determination of nucleotide sugars. A mixture of nucleotide sugars (CMP-NeuAc, UDP-Gal, UDP-Glc, UDP-GalNAc, UDP-GlcNAc, GDP-Man, GDP-Fuc and UDP-GlcUA) and relevant nucleotides were perfectly separated in an optimized ion-pair reversed-phase mode using Inertsil ODS-4 and ODS-3 columns. The newly developed method enabled us to determine the nucleotide sugars in cellular extracts from 1 x 10(6) cells in a single run. We applied this method to characterize nucleotide sugar levels in breast and pancreatic cancer cell lines and revealed that the abundance of UDP-GlcNAc, UDP-GalNAc, UDP-GlcUA and GDP-Fuc were a cell-type-specific feature. To determine the physiological significance of changes in nucleotide sugar levels, we analyzed their changes by glucose deprivation and found that the determination of nucleotide sugar levels provided us with valuable information with respect to studying the overview of cellular glycosylation status.

  15. A novel strategy with standardized reference extract qualification and single compound quantitative evaluation for quality control of Panax notoginseng used as a functional food.

    PubMed

    Li, S P; Qiao, C F; Chen, Y W; Zhao, J; Cui, X M; Zhang, Q W; Liu, X M; Hu, D J

    2013-10-25

    Root of Panax notoginseng (Burk.) F.H. Chen (Sanqi in Chinese) is one of traditional Chinese medicines (TCMs) based functional food. Saponins are the major bioactive components. The shortage of reference compounds or chemical standards is one of the main bottlenecks for quality control of TCMs. A novel strategy, i.e. standardized reference extract based qualification and single calibrated components directly quantitative estimation of multiple analytes, was proposed to easily and effectively control the quality of natural functional foods such as Sanqi. The feasibility and credibility of this methodology were also assessed with a developed fast HPLC method. Five saponins, including ginsenoside Rg1, Re, Rb1, Rd and notoginsenoside R1 were rapidly separated using a conventional HPLC in 20 min. The quantification method was also compared with individual calibration curve method. The strategy is feasible and credible, which is easily and effectively adapted for improving the quality control of natural functional foods such as Sanqi. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. High throughput screening of active pharmaceutical ingredients by UPLC.

    PubMed

    Al-Sayah, Mohammad A; Rizos, Panagiota; Antonucci, Vincent; Wu, Naijun

    2008-07-01

    Ultra performance LC (UPLC) was evaluated as an efficient screening approach to facilitate method development for drug candidates. Three stationary phases were screened: C-18, phenyl, and Shield RP 18 with column dimensions of 150 mm x 2.1 mm, 1.7 microm, which should theoretically generate 35,000 plates or 175% of the typical column plate count of a conventional 250 mm x 4.6 mm, 5 microm particle column. Thirteen different active pharmaceutical ingredients (APIs) were screened using this column set with a standardized mobile-phase gradient. The UPLC method selectivity results were compared to those obtained for these compounds via methods developed through laborious trial and error screening experiments using numerous conventional HPLC mobile and stationary phases. Peak capacity was compared for columns packed with 5 microm particles and columns packed with 1.7 microm particles. The impurities screened by UPLC were confirmed by LC/MS. The results demonstrate that simple, high efficiency UPLC gradients are a feasible and productive alternative to more conventional multiparametric chromatographic screening approaches for many compounds in the early stages of drug development.

  17. Comparison of gamma-oryzanol contents in crude rice bran oils from different sources by various determination methods.

    PubMed

    Yoshie, Ayano; Kanda, Ayato; Nakamura, Takahiro; Igusa, Hisao; Hara, Setsuko

    2009-01-01

    Although there are various determination methods for gamma -oryzanol contained in rice bran oil by absorptiometry, normal-phase HPLC, and reversed-phase HPLC, their accuracies and the correlations among them have not been revealed yet. Chloroform-containing mixed solvents are widely used as mobile phases in some HPLC methods, but researchers have been apprehensive about its use in terms of safety for the human body and the environment.In the present study, a simple and accurate determination method was developed by improving the reversed-phase HPLC method. This novel HPLC method uses methanol/acetonitrile/acetic acid (52/45/3 v/v/v), a non-chlorinated solvent, as the mobile phase, and shows an excellent linearity (y = 0.9527x + 0.1241, R(2) = 0.9974) with absorptiometry. The mean relative errors among the existing 3 methods and the novel method, determined by adding fixed amounts of gamma-oryzanol into refined rice salad oil, were -4.7% for the absorptiometry, -6.8% for the existing normal-phase HPLC, +4.6% for the existing reversed-phase HPLC, and -1.6% for the novel reversed-phase HPLC method. gamma -Oryzanol content in 12 kinds of crude rice bran oils obtained from different sources were determined by the four methods. The mean content of those oils were 1.75+/-0.18% for the absorptiometry, 1.29+/-0.11% for the existing normal-phase HPLC, 1.51+/-0.10% for the existing reversed-phase HPLC, and 1.54+/-0.19% for the novel reversed-phase HPLC method.

  18. Preparation and characterization of progesterone dispersions using supercritical carbon dioxide.

    PubMed

    Falconer, James R; Wen, Jingyuan; Zargar-Shoshtari, Sara; Chen, John J; Farid, Mohammed; Tallon, Stephen J; Alany, Raid G

    2014-04-01

    Supercritical fluid methods offer an alternative to conventional mixing methods, particularly for heat sensitive drugs and where an organic solvent is undesirable. To design, develop and construct a unit for the particles from a gas-saturated suspension/solution (PGSS) method and form endogenous progesterone (PGN) dispersion systems using SC-CO2. The PGN dispersions were manufactured using three selected excipients: polyethylene glycol (PEG) 400/4000 (50:50), Gelucire 44/14 and D-α-tocopheryl PEG 1000 succinate (TPGS). Semisolid dispersions of PGN prepared by PGSS method were compared to the conventional methods; comelting (CM), cosolvent (CS) and physical mixing (PM). The dispersion systems made were characterized by Raman and Fourier transform infrared (FTIR) spectroscopies, X-ray powder diffraction (XRPD), scanning electron microscopy (SEM), PGN recovery, uniformity and in vitro dissolution, analyzed by high-performance liquid chromatography (HPLC). Raman spectra revealed no changes in the crystalline structure of PGN treated with SC-CO2 compared to that of untreated PGN. XRPD and FTIR showed the presence of peaks and bands for PGN confirming that PGN has been incorporated well with each individual excipient. All PGN dispersions prepared by the PGSS method resulted in the improvement of PGN dissolution rates compared to that prepared by the conventional methods and untreated PGN after 60 min (p value < 0.05). The novel PGN dispersions prepared by the PGSS method offer the great potential to enhance PGN dissolution rate, reduce preparation time and form stable crystalline dispersion systems over those prepared by conventional methods.

  19. 77 FR 67282 - Dinotefuran; Pesticide Tolerances for Emergency Exemptions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-09

    ... performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) method is available. For the determination of residues of dinotefuran only, an HPLC/ultraviolet (UV) detection method is available. For the determination of only the metabolites (DN and UF), HPLC/MS and HPLC/MS/MS methods are available. These methods...

  20. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.

    PubMed

    Robitaille, Line; Hoffer, L John

    2016-04-21

    In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.

  1. Application of multibounce attenuated total reflectance fourier transform infrared spectroscopy and chemometrics for determination of aspartame in soft drinks.

    PubMed

    Khurana, Harpreet Kaur; Cho, Il Kyu; Shim, Jae Yong; Li, Qing X; Jun, Soojin

    2008-02-13

    Aspartame is a low-calorie sweetener commonly used in soft drinks; however, the maximum usage dose is limited by the U.S. Food and Drug Administration. Fourier transform infrared (FTIR) spectroscopy with attenuated total reflectance sampling accessory and partial least-squares regression (PLS) was used for rapid determination of aspartame in soft drinks. On the basis of spectral characterization, the highest R2 value, and lowest PRESS value, the spectral region between 1600 and 1900 cm(-1) was selected for quantitative estimation of aspartame. The potential of FTIR spectroscopy for aspartame quantification was examined and validated by the conventional HPLC method. Using the FTIR method, aspartame contents in four selected carbonated diet soft drinks were found to average from 0.43 to 0.50 mg/mL with prediction errors ranging from 2.4 to 5.7% when compared with HPLC measurements. The developed method also showed a high degree of accuracy because real samples were used for calibration, thus minimizing potential interference errors. The FTIR method developed can be suitably used for routine quality control analysis of aspartame in the beverage-manufacturing sector.

  2. Quantitation of fumonisin B1 and B2 in feed using FMOC pre-column derivatization with HPLC and fluorescence detection.

    PubMed

    Smith, Lori L; Francis, Kyle A; Johnson, Joseph T; Gaskill, Cynthia L

    2017-11-01

    Pre-column derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) was determined to be effective for quantitation of fumonisins B 1 and B 2 in feed. Liquid-solid extraction, clean-up using immunoaffinity solid phase extraction chromatography, and FMOC-derivatization preceded analysis by reverse phase HPLC with fluorescence. Instrument response was unchanged in the presence of matrix, indicating no need to use matrix-matched calibrants. Furthermore, high method recoveries indicated calibrants do not need to undergo clean-up to account for analyte loss. Established method features include linear instrument response from 0.04-2.5µg/mL and stable derivatized calibrants over 7days. Fortified cornmeal method recoveries from 0.1-30.0μg/g were determined for FB 1 (75.1%-109%) and FB 2 (96.0%-115.2%). Inter-assay precision ranged from 1.0%-16.7%. Method accuracy was further confirmed using certified reference material. Inter-laboratory comparison with naturally-contaminated field corn demonstrated equivalent results with conventional derivatization. These results indicate FMOC derivatization is a suitable alternative for fumonisins B 1 and B 2 quantitation in corn-based feeds. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Application of fermentation for isoflavone extraction from soy molasses

    NASA Astrophysics Data System (ADS)

    Duru, K. C.; Kovaleva, E. G.; Glukhareva, T. V.

    2017-09-01

    Extraction of isoflavones from soy products remains a major challenge for researchers. Different extraction techniques have been employed but the need to use a cheap green extraction technique remains the main focus. This study applied fermentation of soy molasses using Saccharomyces cerevisiae for extraction of isoflavones and compared this technique to the conventional extraction method. The aluminum chloride colorimetric method was used for the determination of total flavonoid content of extracts. The highest yield was observed from extraction using ethyl acetate after fermentation of soy molasses and the lowest one was given by the extract from conventional extraction method. The DPPH radical scavenging activities of the extracts were also compared. The extract obtained using ethyl acetate after fermentation showed the highest antioxidant activity (0.0269 meq), while extract from conventional extraction had the lowest antioxidant activity (0.0055 meq). The effect of time on daidzein yield was studied using HPLC standard addition method. Daidzein concentration was higher in extract obtained at t = 80 min (3.82 ± 0.11 mg of daidzein /g of extract) as compared to that obtained at t = 60 min (2.89 ± 0.10 mg of daidzein /g of extract).

  4. The carotenoid pigments of a marine Bacillus firmus strain.

    PubMed

    Pane, L; Radin, L; Franconi, G; Carli, A

    1996-01-01

    As carotenoids have important biological functions, it is important to discover new natural sources of these pigments. The bacterial strains isolated from a sea water rock pool were cultivated on marine agar containing yeast extract and identified by conventional methods. The bacterial pigments were extracted with methanol and analyzed by reversed-phase HPLC with diode array detection. The major pigment of a Bacillus firmus strain was identified as astaxanthin; the results obtained suggest potential use of this bacterium in aquaculture and in pharmaceutical field.

  5. Aqueous Peroxyoxalate Chemiluminescence.

    DTIC Science & Technology

    1982-01-01

    fluorescence. It should be noted that the chloromethylstyrene, 45, was actually a mixture of the meta and para isomers as received from the supplier...the pentaetWyleneoxy acetylenic derivative, 65. By the conventional scheme, bis-pentaethyleneoxy-BPEA, 66, was obtained as an oil, even after HPLC ...phenylacetylide or lithium amide. The attempted hydrolysis of 56 using NaOH/DMF at reflux gave a semi-solid product, which was not totally pure even after HPLC

  6. Development of a micropulverized extraction method for rapid toxicological analysis of methamphetamine in hair.

    PubMed

    Miyaguchi, Hajime; Kakuta, Masaya; Iwata, Yuko T; Matsuda, Hideaki; Tazawa, Hidekatsu; Kimura, Hiroko; Inoue, Hiroyuki

    2007-09-07

    We developed a rapid sample preparation method for the toxicological analysis of methamphetamine and amphetamine (the major metabolite of methamphetamine) in human hair by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS), to facilitate fast screening and quantitation. Two milligrams of hair were mechanically micropulverized for 5 min in a 2-ml plastic tube together with 100 microl of an aqueous solvent containing 10% acetonitrile, 100 mM trifluoroacetic acid and the corresponding deuterium analogues as internal standards. The pulverizing highly disintegrated the hair components, simultaneously allowing the extraction of any drugs present in the hair. After filtering the suspension with a membrane-filter unit, the clear filtrate was directly analyzed by HPLC-MS/MS. No evaporation processes were required for sample preparation. Method optimization and validation study were carried out using real-case specimens and fortified samples in which the drugs had been artificially absorbed, respectively. Concentration ranges for quantitation were 0.040-125 and 0.040-25 ng/mg for methamphetamine and amphetamine, respectively. Real-case specimens were analyzed by the method presented here and by conventional ones to verify the applicability of our method to real-world analysis. Our method took less than 30 min for a set of chromatograms to be obtained from a washed hair sample.

  7. Characterization and identification of multiple constituents in Yinhuang granules by high-performance liquid chromatography with diode-array and time-of-flight mass spectrometry detection.

    PubMed

    Liu, E-Hu; Liu, Qun; Chu, Chu; Li, Ping

    2011-10-01

    A fast high-performance liquid chromatography (HPLC) method with diode-array detection (DAD) and time-of-flight mass spectrometry (TOF/MS) has been developed for the analysis of multi-constituent in Yinhuang granules, a well-known combined herbal remedy prepared from the extract mixtures of Flos Lonicerae and Radix Scutellariae. The fast HPLC analysis was performed on an Agilent ZorBax SB-C(18) column (4.6×50 mm, 1.8 μm) and 0.2% aqueous formic acid and acetonitrile was the optimum mobile phase for gradient elution in 17 min, which is five times faster than the performance of conventional columns packed with 5.0 μm particles. With various fragmentor voltages in TOF/MS, accurate mass measurements (<5 ppm error) for molecular ions and characteristic fragment ions represented reliable identification criteria for different constituents. A total of 28 compounds, including nine phenolic acids, three iridoid glycosides and nine saponins from Flos Lonicerae and seven flavonoids from Radix Scutellariae, were identified or tentatively characterized in the extract of Yinhuang granules. The established fast HPLC-DAD-TOF/MS method turns out to be useful and efficient for quality control of this commonly used Chinese herbal preparation. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. High-efficiency high performance liquid chromatographic analysis of red wine anthocyanins.

    PubMed

    de Villiers, André; Cabooter, Deirdre; Lynen, Frédéric; Desmet, Gert; Sandra, Pat

    2011-07-22

    The analysis of anthocyanins in natural products is of significant relevance in recent times due to the recognised health benefits associated with their consumption. In red grapes and wines in particular, anthocyanins are known to contribute important properties to the sensory (colour and taste), anti-oxidant- and ageing characteristics. However, the detailed investigation of the alteration of these compounds during wine ageing is hampered by the challenges associated with the separation of grape-derived anthocyanins and their derived products. High performance liquid chromatography (HPLC) is primarily used for this purpose, often in combination with mass spectrometric (MS) detection, although conventional HPLC methods provide incomplete resolution. We have previously demonstrated how on-column inter-conversion reactions are responsible for poor chromatographic efficiency in the HPLC analysis of anthocyanins, and how an increase in temperature and decrease in particle size may improve the chromatographic performance. In the current contribution an experimental configuration for the high efficiency analysis of anthocyanins is derived using the kinetic plot method (KPM). Further, it is shown how analysis under optimal conditions, in combination with MS detection, delivers much improved separation and identification of red wine anthocyanins and their derived products. This improved analytical performance holds promise for the in-depth investigation of these influential compounds in wine during ageing. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Qualitative and quantitative analysis of the diuretic component ergone in Polyporus umbellatus by HPLC with fluorescence detection and HPLC-APCI-MS/MS.

    PubMed

    Zhao, Ying-Yong; Zhao, Ye; Zhang, Yong-Min; Lin, Rui-Chao; Sun, Wen-Ji

    2009-06-01

    Polyporus umbellatus is a widely used anti-aldosteronic diuretic in Traditional Chinese medicine (TCM). A new, sensitive and selective high-performance liquid chromatography-fluorescence detector (HPLC-FLD) and high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (HPLC-APCI-MS/MS) method for quantitative and qualitative determination of ergosta-4,6,8(14),22-tetraen-3-one(ergone), which is the main diuretic component, was provided for quality control of P. umbellatus crude drug. The ergone in the ethanolic extract of P. umbellatus was unambiguously characterized by HPLC-APCI, and further confirmed by comparing with a standard compound. The trace ergone was detected by the sensitive and selective HPLC-FLD. Linearity (r2 > 0.9998) and recoveries of low, medium and high concentration (100.5%, 100.2% and 100.4%) were consistent with the experimental criteria. The limit of detection (LOD) of ergone was around 0.2 microg/mL. Our results indicated that the content of ergone in P. umbellatus varied significantly from habitat to habitat with contents ranging from 2.13 +/- 0.02 to 59.17 +/- 0.05 microg/g. Comparison among HPLC-FLD and HPLC-UV or HPLC-APCI-MS/MS demonstrated that the HPLC-FLD and HPLC-APCI-MS/MS methods gave similar quantitative results for the selected herb samples, the HPLC-UV methods gave lower quantitative results than HPLC-FLD and HPLC-APCI-MS/MS methods. The established new HPLC-FLD method has the advantages of being rapid, simple, selective and sensitive, and could be used for the routine analysis of P. umbellatus crude drug.

  10. Improved GMP-compliant multi-dose production and quality control of 6-[18F]fluoro-L-DOPA.

    PubMed

    Luurtsema, G; Boersma, H H; Schepers, M; de Vries, A M T; Maas, B; Zijlma, R; de Vries, E F J; Elsinga, P H

    2017-01-01

    6-[ 18 F]Fluoro-L-3,4-dihydroxyphenylalanine (FDOPA) is a frequently used radiopharmaceutical for detecting neuroendocrine and brain tumors and for the differential diagnosis of Parkinson's disease. To meet the demand for FDOPA, a high-yield GMP-compliant production method is required. Therefore, this study aimed to improve the FDOPA production and quality control procedures to enable distribution of the radiopharmaceutical over distances.FDOPA was prepared by electrophilic fluorination of the trimethylstannyl precursor with [ 18 F]F 2 , produced from [ 18 O] 2 via the double-shoot approach, leading to FDOPA with higher specific activity as compared to FDOPA which was synthesized, using [ 18 F]F 2 produced from 20 Ne, leading to FDOPA with a lower specific activity. The quality control of the product was performed using a validated UPLC system and compared with quality control with a conventional HPLC system. Impurities were identified using UPLC-MS. The [ 18 O] 2 double-shoot radionuclide production method yielded significantly more [ 18 F]F 2 with less carrier F 2 than the conventional method starting from 20 Ne. After adjustment of radiolabeling parameters substantially higher amounts of FDOPA with higher specific activity could be obtained. Quality control by UPLC was much faster and detected more side-products than HPLC. UPLC-MS showed that the most important side-product was FDOPA-quinone, rather than 6-hydroxydopa as suggested by the European Pharmacopoeia. The production and quality control of FDOPA were significantly improved by introducing the [ 18 O] 2 double-shoot radionuclide production method, and product analysis by UPLC, respectively. As a result, FDOPA is now routinely available for clinical practice and for distribution over distances.

  11. Comparison of systemic absorption between ofloxacin ophthalmic in situ gels and ofloxacin conventional ophthalmic solutions administration to rabbit eyes by HPLC-MS/MS.

    PubMed

    Li, Jiawei; Zhao, Hainan; Okeke, Chukwunweike Ikechukwu; Li, Lin; Liu, Zhidong; Yin, Zhongpeng; Zhuang, Pengwei; Sun, Jingtong; Wu, Tao; Wang, Meng; Li, Nan; Pi, Jiaxin; Zhang, Qian; Zhang, Rui; Ma, Li; Pang, Xiaochen; Liu, Zhanbiao; Zhang, Li; Fan, Lili

    2013-06-25

    In recent years, many pharmaceutical scientists have focused on developing the in situ gel-forming systems to overcome the poor bioavailability and therapeutic response exhibited by conventional ophthalmic solutions due to rapid pre-corneal elimination of the drug. The present work was to compare the systemic absorptions of ophthalmic ofloxacin in situ gel with the conventional ofloxacin eye drop after topical instillation to rabbit eyes by HPLC-MS/MS method and also determine the relative contribution of the nasal and the conjunctival mucosae to systemic ofloxacin absorption following topical instillation. The systemic AUC, Cmax, Tmax and Ke for ophthalmic in situ gel and ophthalmic solution after ocular instillation were 202.63±118.85 and 202.25±57.74 ng mL(-1) h, 54.22±28.31 and 48.4±25.97 ng mL(-1), 1.08±0.20 and 1.25±0.88 h, 0.0576±0.0207 and 0.0388±0.0248, respectively. And the values for the ratios of the AUC of anterior chamber of rabbit eye to blood plasma, AUCac/AUCpl, for ofloxacin conventional eye drop and in situ gel were 0.25 and 0.52, respectively. Statistic results showed that there was no significant difference in systemic absorption between the test groups and the reference groups (P>0.05) as both formulations have an AUCsa/AUCpl of 0.35. Therefore, the ophthalmic in situ gel may not decrease the drugs systemic absorption when administered in an equivalent dose as ophthalmic solutions into the rabbit eyes. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Effects of Gymnema sylvestre extract on the pharmacokinetics and pharmacodynamics of glimepiride in streptozotocin induced diabetic rats.

    PubMed

    Kamble, Bhagyashree; Gupta, Ankur; Moothedath, Ismail; Khatal, Laxman; Janrao, Shirish; Jadhav, Amol; Duraiswamy, B

    2016-02-05

    Gymnema sylvestre, important Indian traditional herbal medicine has been used for diabetes from several years and marketed as single or multi-herb formulations globally. People are consuming G. sylvestre along with conventional hypoglycemic drugs. Therefore, there is need of evidence based assessment of risk versus benefits when G. sylvestre co-administered with conventional oral hypoglycemic drugs. In present investigation, pharmacodynamics and pharmacokinetic interactions with oral hypoglycemic drug, glimepiride (GLM) was studied in streptozotocin (STZ) induced diabetic rats. A specific and rapid HPLC-ESI-MS/MS method was established for simultaneous quantification of GLM and gymnemagenin (GMG) in rat plasma. Pharmacokinetic and pharmacodynamic interaction studies were carried out in STZ induced diabetic rats after concomitant administration of 400 mg/kg of G. sylvestre extract and 0.8 mg/kg of GLM for 28 days. The developed HPLC-ESI-MS/MS method was rapid, specific, and precise. Con-comitant oral administration of G. sylvestre extract (400 mg/kg) and GLM (0.8 mg/kg) in diabetic rats for 28 days showed beneficial pharmacodynamic interactions whereas no major alterations in the pharmacokinetics parameters of GLM and GMG were observed. This interaction demonstrated in animal model implies that significant clinical outcome might occur during concomitant administration of G. sylvestre extract and GLM especially in diabetic patients and warrants further studies in the same set up. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. Mobility and persistence of the herbicide fomesafen in soils cultivated with bean plants using SLE/LTP and HPLC/DAD.

    PubMed

    Costa, Anna I G; Queiroz, Maria Eliana L R; Neves, Antônio A; de Assis, Roberta C; dos Soares, Carlos E S; da Silva, Antônio A; D'Antonino, Leonardo; de Oliveira, André F; Bellato, Carlos R

    2015-03-01

    A method has been optimized and validated for the determination of fomesafen in soils using solid-liquid extraction with low-temperature partitioning (SLE/LTP) and analysis by liquid chromatography with a high-efficiency diode array detector (HPLC/DAD). The method was used to evaluate the persistence and mobility of this herbicide in different soils cultivated with bean plants. Recovery values were ≥98.9 %, with variations in the repeatability coefficients of ≤15 %, and a detection limit of 7.3 μg kg(-1). Half-life values of fomesafen were between 60 and 71 days in soil cultivated using a no-till system and 99 and 114 days in soil cultivated using a conventional tillage system. The mobility of fomesafen was moderate and mainly influenced by the organic matter content, pH, and soil type. In Red-Yellow Argisol, which has a higher content of organic matter, the leaching of fomesafen was less pronounced. In Red-Yellow Latosol, which has smaller amounts of organic matter and high pH, the leaching of fomesafen was more pronounced.

  14. G-index: A new metric to describe dynamic refractive index effects in HPLC absorbance detection.

    PubMed

    Kraiczek, Karsten G; Rozing, Gerard P; Zengerle, Roland

    2018-09-01

    High performance liquid chromatography (HPLC) with a solvent gradient and absorbance detection is one of the most widely used methods in analytical chemistry. The observed absorbance baseline is affected by the changes in the refractive index (RI) of the mobile phase. Near the limited of detection, this complicates peak quantitation. The general aspects of these RI-induced apparent absorbance effects are discussed. Two different detectors with fundamentally different optics and flow cell concepts, a variable-wavelength detector equipped with a conventional flow cell and a diode-array detector equipped with a liquid core waveguide flow cell, are compared with respect to their RI behavior. A simple method to separate static - partly unavoidable - RI effects from dynamic RI effects is presented. It is shown that the dynamic RI behavior of an absorbance detector can be well described using a single, relatively easy-to-determine metric called the G-index. The G-index is typically in the order of a few seconds and its sign depends on the optical flow cell concept. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Rapid Quantitative Analysis of Naringenin in the Fruit Bodies of Inonotus vaninii by Two-phase Acid Hydrolysis Followed by Reversed Phase-high Performance Liquid Chromatography-ultra Violet.

    PubMed

    Guohua, Xia; Pan, Ruirong; Bao, Rui; Ge, Yanru; Zhou, Cunshan; Shen, Yuping

    2017-01-01

    Sanghuang is one of mystical traditional Chinese medicines recorded earliest 2000 years ago, that included various fungi of Inonotus genus and was well-known for antitumor effect in modern medicine. Inonotus vaninii is grown in natural forest of Northeastern China merely and used as Sanghuang commercially, but it has no quality control specification until now. This study was to establish a rapid method of two-phase acid hydrolysis followed by reversed phase-high performance liquid chromatography-ultra violet (RP-HPLC-UV) to quantify naringenin in the fruit body of I. vaninii . Sample solution was prepared by pretreatment of raw material in two-phase acid hydrolysis and the hydrolysis technology was optimized. After reconstitution, analysis was performed using RP-HPLC-UV. The method validation was investigated and the naringenin content of sample and comparison were determined. The naringenin was obtained by two-phase acid hydrolysis method, namely, 10.0 g of raw material was hydrolyzed in 200 mL of 1% sulfuric acid aqueous solution (v/v) and 400 mL of chloroform in oil bath at 110°C for 2 h. Good linearity ( r = 0.9992) was achieved between concentration of analyte and peak area. The relative standard deviation (RSD) of precision was 2.47% and the RSD of naringenin contents for repeatability was 3.13%. The accuracy was supported with recoveries at 96.37%, 97.30%, and 99.31%. The sample solution prepared using the proposed method contained higher content of naringenin than conventional method and was stable for 8 h. Due to the high efficiency of sample preparation and high reliability of the HPLC method, it is feasible to use this method for routine analysis of naringenin in the fungus. A convenient two-phase acid hydrolysis was employed to produce naringenin from raw material, and then an efficient and reliable reversed phase-high performance liquid chromatography-ultra violet method was established to monitor naringenin in the fruit bodies of Inonotus vaninii . The newly established method could be used to control the quality of the herb. Abbreviations used: RP-HPLC-UV: Reversed Phase-High Performance Liquid Chromatography-Ultra Violet, RSD: Relative Standard Deviation, EtOAc: Ethyl acetate, ACN: Acetonitrile, MeOH: Methanol, RH: Relative Humility.

  16. Comparison of HPLC & spectrophotometric methods for estimation of antiretroviral drug content in pharmaceutical products.

    PubMed

    Hemanth Kumar, A K; Sudha, V; Swaminathan, Soumya; Ramachandran, Geetha

    2010-10-01

    Simple and reliable methods to estimate drugs in pharmaceutical products are needed. In most cases, antiretroviral drug estimations are performed using a HPLC method, requiring expensive equipment and trained technicians. A relatively simple and accurate method to estimate antiretroviral drugs in pharmaceutical preparations is by spectrophotometric method, which is cheap and simple to use as compared to HPLC. We undertook this study to standardise methods for estimation of nevirapine (NVP), lamivudine (3TC) and stavudine (d4T) in single tablets/capsules by HPLC and spectrophotometry and to compare the content of these drugs determined by both these methods. Twenty tablets/capsules of NVP, 3TC and d4T each were analysed for their drug content by HPLC and spectrophotometric methods. Suitably diluted drug solutions were run on HPLC fitted with a C18 column using UV detection at ambient temperature. The absorbance of the diluted drug solutions were read in a spectrophotometer at 300, 285 and 270 nm for NVP, 3TC and d4T respectively. Pure powders of the drugs were used to prepare calibration standards of known drug concentrations, which was set up with each assay. The inter-day variation (%) of standards for NVP, 3TC and d4T ranged from 2.5 to 6.7, 2.1 to 7.7 and 6.2 to 7.7, respectively by HPLC. The corresponding values by spectrophotometric method were 2.7 to 4.7, 4.2 to 7.2 and 3.8 to 6.0. The per cent variation between the HPLC and spectrophotometric methods ranged from 0.45 to 4.49 per cent, 0 to 4.98 per cent and 0.35 to 8.73 per cent for NVP, 3TC and d4T,respectively. The contents of NVP, 3TC and d4T in the tablets estimated by HPLC and spectrophotometric methods were similar, and the variation in the amount of these drugs estimated by HPLC and spectrophotometric methods was below 10 per cent. This suggests that the spectrophotometric method is as accurate as the HPLC method for estimation of NVP, 3TC and d4T in tablet/capsule. Hence laboratories that do not have HPLC equipment can also undertake these drug estimations using spectrophotometer.

  17. Biological Activity of Conventional and Organic Pomegranate Juices: Antioxidant and Antimutagenic Potential.

    PubMed

    Cano-Lamadrid, M; Marhuenda-Egea, F C; Hernández, F; Rosas-Burgos, E C; Burgos-Hernández, A; Carbonell-Barrachina, A A

    2016-12-01

    None of the health claims about pomegranate juices has been approved yet by European Food Safety Authority (EFSA). There is a general perception among consumers that organic foods are healthier, tastier, and more nutritive than the conventional products. The aim of this research was to study the differences in the biological activity between ready-for-consumption juices obtained from pomegranates fruits grown under conventional and organic agricultural practices. Antioxidant activity has been evaluated by three methods (DPPH • , ABTS + , and FRAP), together with the total contents of phenolics and punicalagin (HPLC-DAD); besides, the Ames test was used to evaluate the antimutagenic potential of the juices. Pomegranate juice, either from conventionally or organically grown fruits, was antimutagenic (mean of 51 and 90 % for Salmonella typhimurium TA100 and TA98, respectively) and it was capable of protecting DNA from both, base-pair or frame-shift type of mutations. In fact, the antimutagenicity of conventional pomegranate juice was higher than that achieved by the organic sample; this finding was linked to a higher punicalagin content (201 and 104 mg L -1 for conventional and organic juices, respectively).

  18. Analytical Characterization of an Oil-in-Water Adjuvant Emulsion.

    PubMed

    Sun, Jenny; Remmele, Richard L; Sanyal, Gautam

    2017-07-01

    Adjuvants are typically used in subunit vaccine formulations to enhance immune responses elicited by individual antigens. Physical chemical characterization of novel adjuvants is an important step in ensuring their effective use in vaccine formulations. This paper reports application of a panel of quantitative assays developed to analyze and characterize an oil-in-water adjuvant emulsion, which contains glucopyranosyl lipid A (GLA) and is a squalene-based emulsion. GLA is a fully synthetic analogue of monophosphoryl lipid A, which is a Toll-like receptor type 4 agonist and an FDA-approved adjuvant. The GLA-stable emulsion (GLA-SE) is currently being used for a respiratory syncytial virus vaccine in a phase 2 clinical trial. GLA was quantitated using reverse-phased high-performance liquid chromatography (RP-HPLC) coupled to a mass spectrometric detector, achieving higher assay sensitivity than the charged aerosol detection routinely used. Quantitation of the excipients of GLA-SE, including squalene, egg phosphatidyl choline, and Poloxamer 188, was achieved using a simple and rapid RP-HPLC method with evaporative light scattering detection, eliminating chemical derivatization typically required for these chromophore-lacking compounds. DL-α-tocopherol, the antioxidant of the GLA-SE, was quantitated using a RP-HPLC method with conventional UV detection. The experimental results compared well with values expected for these compounds based on targeted composition of the adjuvant. The assays were applied to identify degradation of individual components in a GLA-SE sample that degraded into distinct aqueous and oil phases. The methods developed and reported here are effective tools in monitoring physicochemical integrity of the adjuvant, as well as in formulation studies.

  19. Home-made online hyphenation of pressurized liquid extraction, turbulent flow chromatography, and high performance liquid chromatography, Cistanche deserticola as a case study.

    PubMed

    Song, Qingqing; Li, Jun; Liu, Xiao; Zhang, Yuan; Guo, Liping; Jiang, Yong; Song, Yuelin; Tu, Pengfei

    2016-03-18

    Incompatibility between the conventional pressurized liquid extraction (PLE) devices and high performance liquid chromatography (HPLC) extensively hinders direct and green chemical analysis of herbal materials. Herein, a facile PLE module was configured, and then it was online hyphenated with HPLC via a turbulent flow chromatography (TFC) column. Regarding PLE module, a long PEEK tube (0.13 × 1000 mm) was employed to generate desired pressure (approximately 13.0 MPa) when warm acidic water (70 °C) was delivered as extraction solvent at a high flow rate (2.5 mL/min), and a hollow guard column (3.0 × 4.0 mm) was implemented to hold crude materials. Effluent was collected from the outlet of PEEK tube, concentrated, and subjected onto HPLC coupled with hybrid ion trap-time of flight mass spectrometer to assess the extraction efficiency and also to profile the chemical composition of Cistanche deserticola (CD) that is honored as "Ginseng of the desert". Afterwards, a TFC column was introduced to accomplish online transmission of low molecule weight components from PLE module to HPLC coupled with diode array detection, and two electronic 6-port/2-channel valves were in charge of alternating the whole system between extraction (0-3.0 min) and elution (3.0-35.0 min) phases. Quantitative method was developed and validated for simultaneous determination of eight primary phenylethanoid glycosides in CD using online PLE-TFC-HPLC. All findings demonstrated that the home-made platform is advantageous at direct chemical analysis, as well as time-, solvent-, and material-savings, suggesting a robust tool for chemical fingerprinting of herbs. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Chemical fingerprint and simultaneous determination of alkaloids and flavonoids in aerial parts of genus Peganum indigenous to China based on HPLC-UV: application of analysis on secondary metabolites accumulation.

    PubMed

    Wen, Fangfang; Cheng, Xuemei; Liu, Wei; Xuan, Min; Zhang, Lei; Zhao, Xin; Shan, Meng; Li, Yan; Teng, Liang; Wang, Zhengtao; Wang, Changhong

    2014-12-01

    The aerial parts of genus Peganum are officially used in traditional Chinese medicine. The paper aims to establish a high-performance liquid chromatography (HPLC) method for fingerprint analysis and simultaneous determination of three alkaloids and two flavonoids in aerial parts of genus Peganum, and to analyze accumulative difference of secondary metabolites in inter-species, individuals of plants, inter-/intra-population and from different growing seasons. HPLC analysis was performed on a C18 column with gradient elution using 0.1% trifloroacetic acid and acetonitrile as mobile phase and detected at 265 nm, by conventional methodology validation. For fingerprint analysis, the RSDs of relative retention time and relative peak area of the characteristic peaks were within 0.07-0.78 and 0.94-9.09%, respectively. For simultaneous determination of vasicine, harmaline, harmine, deacetylpeganetin and peganetin, all calibration curves showed good linearity (r > 0.9990) within the test range. The relative standard deviations of precision, repeatability and stability test did not exceed 2.37, 2.68 and 2.67%, respectively. The average recoveries for the five analytes were between 96.47 and 101.20%. HPLC fingerprints play a minor role in authenticating and differentiating the herbs of different species of genus Peganum. However, the secondary metabolites levels of alkaloids and flavonoids in aerial parts of genus Peganum rely on species-, habitat-, and growth season-dependent accumulation. Copyright © 2014 John Wiley & Sons, Ltd.

  1. Comparative evaluation of an ISO 3632 method and an HPLC-DAD method for safranal quantity determination in saffron.

    PubMed

    García-Rodríguez, M Valle; López-Córcoles, Horacio; Alonso, Gonzalo L; Pappas, Christos S; Polissiou, Moschos G; Tarantilis, Petros A

    2017-04-15

    The aim of this work was a comparison of the ISO 3632 (2011) method and an HPLC-DAD method for safranal quantity determination in saffron. Samples from different origins were analysed by UV-vis according to ISO 3632 (2011) and by HPLC-DAD. Both methods were compared, and there was no correlation between the safranal content obtained by UV-vis and HPLC-DAD. An over-estimation in the UV-vis experiment was observed, which was related to the cis-crocetin esters content, as well as other compounds. The results demonstrated that there was no relationship between ISO quality categories and safranal content using HPLC-DAD. Therefore, HPLC-DAD might be preferable to UV-vis for determining the safranal content and the classification of saffron for commercial purposes. In addition, HPLC-DAD was adequate for determining the three foremost parameters that define the quality of saffron (crocetin esters, picrocrocin and safranal); therefore, this approach could be included in the ISO 3632 method (2011). Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Chemical composition, potential toxicity, and quality control procedures of the crude drug of Cyrtopodium macrobulbon.

    PubMed

    Morales-Sánchez, Viridiana; Rivero-Cruz, Isabel; Laguna-Hernández, Guillermo; Salazar-Chávez, Gerardo; Mata, Rachel

    2014-07-03

    Cyrtopodium macrobulbon ("cañaveral") has been long used in Mexican traditional medicine for the treatment of painful urinary ailments ("mal de orin") in men. This study was conducted (i) to establish the potential acute toxicity and the antinociceptive activity of some preparations of Cyrtopodium macrobulbon, in order to demonstrate its preclinical efficacy for treating symptoms of "mal de orin"; and (ii) to determine the chemical composition and quality control parameters of this medicinal orchid. The antinociceptive effect was assessed using the acetic acid-induced writhing and the hot-plate tests. Investigation of the acute toxicity was accomplished by the Lorke method. The organic extract (OE) was subjected to conventional phytochemical study using chromatographic conventional procedures. The volatile components profile of the species was accomplished via GC-MS analysis of HS-SPME-adsorbed compounds. Furthermore, an HPLC method to quantify ephemeranthol B (10) was developed and validated according to the International Conference on Harmonization Guidelines. Microscopic anatomy studies were performed using light and scanning electron microscopies. Finally, a potential distribution map was generated using the MaxEnt modeling method. AE and OE were not toxic to mice since the LD50 was higher than 5000 mg/kg. OE was only active in the acetic acid-induced writhing assay at the doses of 100 and 316 mg/kg. Conventional phytochemical analysis of OE led to the isolation and characterization of n-hexacosyl-trans-p-coumarate (1), n-octacosyl-trans-p-coumarate (2), n-triacontyl-trans-p-coumarate (3), 4-methoxy-benzyl alcohol (4), 4-hydroxybenzaldehyde (5), 1,5,7-trimethoxy-9,10-dihydrophenanthrene-2,6-diol (6), confusarin (7), gigantol (8), batatasin III (9), and ephemeranthol B (10). The major volatile components identified by HS-SPME analysis were 6,10,14-trimethyl-2-pentadecanone, eucalyptol (11), and isobornyl formate. An HPLC analytical method for the quantification of compound 10 in the plant was developed and fully validated for selectivity, accuracy, and precision. The microscopic studies revealed that the epidermal tissue displayed a layer of enlarged, crenate and cell thin-walled cells with a thickened cuticle; these cells are described for first time for this species. The potential distribution map generated revealed that this species is widespread in Mexico from Sinaloa to Merida states. The results of the pharmacological studies tend to support the traditional use of Cyrtopodium macrobulbon for "mal de orin"; the presence of compounds 8, 9, and 11 with known antinociceptive activity might be related with the pharmacological effect demonstrated. The HPLC and microscopic analyses developed in this work will be valuable tools for quality control purposes for this plant. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Nontargeted quantitation of lipid classes using hydrophilic interaction liquid chromatography-electrospray ionization mass spectrometry with single internal standard and response factor approach.

    PubMed

    Cífková, Eva; Holčapek, Michal; Lísa, Miroslav; Ovčačíková, Magdaléna; Lyčka, Antonín; Lynen, Frédéric; Sandra, Pat

    2012-11-20

    The identification and quantitation of a wide range of lipids in complex biological samples is an essential requirement for the lipidomic studies. High-performance liquid chromatography-mass spectrometry (HPLC/MS) has the highest potential to obtain detailed information on the whole lipidome, but the reliable quantitation of multiple lipid classes is still a challenging task. In this work, we describe a new method for the nontargeted quantitation of polar lipid classes separated by hydrophilic interaction liquid chromatography (HILIC) followed by positive-ion electrospray ionization mass spectrometry (ESI-MS) using a single internal lipid standard to which all class specific response factors (RFs) are related to. The developed method enables the nontargeted quantitation of lipid classes and molecules inside these classes in contrast to the conventional targeted quantitation, which is based on predefined selected reaction monitoring (SRM) transitions for selected lipids only. In the nontargeted quantitation method described here, concentrations of lipid classes are obtained by the peak integration in HILIC chromatograms multiplied by their RFs related to the single internal standard (i.e., sphingosyl PE, d17:1/12:0) used as common reference for all polar lipid classes. The accuracy, reproducibility and robustness of the method have been checked by various means: (1) the comparison with conventional lipidomic quantitation using SRM scans on a triple quadrupole (QqQ) mass analyzer, (2) (31)P nuclear magnetic resonance (NMR) quantitation of the total lipid extract, (3) method robustness test using subsequent measurements by three different persons, (4) method transfer to different HPLC/MS systems using different chromatographic conditions, and (5) comparison with previously published results for identical samples, especially human reference plasma from the National Institute of Standards and Technology (NIST human plasma). Results on human plasma, egg yolk and porcine liver extracts are presented and discussed.

  4. The use of capillary electrophoresis as part of a specificity testing strategy for mitoguazone dihydrochloride HPLC methods.

    PubMed

    Thomson, C E; Gray, M R; Baxter, M P

    1997-05-01

    Capillary electrophoresis (CE) has been used as part of a validation experiment designed to prove the specificity of high performance liquid chromatography (HPLC) methods used for analysis of mitoguazone dihydrochloride drug substance. Data regarding accuracy, precision and sensitivity of the CE methods are presented as well as a comparison of results obtained from CE, HPLC and thin-layer chromatography (TLC) analysis of samples stressed under a variety of conditions. It was concluded that, not only were the HPLC methods being investigated specific, but that CE could potentially be used to replace HPLC for the routine assay of mitoguazone dihydrochloride.

  5. Optimization of sample preparation variables for wedelolactone from Eclipta alba using Box-Behnken experimental design followed by HPLC identification.

    PubMed

    Patil, A A; Sachin, B S; Shinde, D B; Wakte, P S

    2013-07-01

    Coumestan wedelolactone is an important phytocomponent from Eclipta alba (L.) Hassk. It possesses diverse pharmacological activities, which have prompted the development of various extraction techniques and strategies for its better utilization. The aim of the present study is to develop and optimize supercritical carbon dioxide assisted sample preparation and HPLC identification of wedelolactone from E. alba (L.) Hassk. The response surface methodology was employed to study the optimization of sample preparation using supercritical carbon dioxide for wedelolactone from E. alba (L.) Hassk. The optimized sample preparation involves the investigation of quantitative effects of sample preparation parameters viz. operating pressure, temperature, modifier concentration and time on yield of wedelolactone using Box-Behnken design. The wedelolactone content was determined using validated HPLC methodology. The experimental data were fitted to second-order polynomial equation using multiple regression analysis and analyzed using the appropriate statistical method. By solving the regression equation and analyzing 3D plots, the optimum extraction conditions were found to be: extraction pressure, 25 MPa; temperature, 56 °C; modifier concentration, 9.44% and extraction time, 60 min. Optimum extraction conditions demonstrated wedelolactone yield of 15.37 ± 0.63 mg/100 g E. alba (L.) Hassk, which was in good agreement with the predicted values. Temperature and modifier concentration showed significant effect on the wedelolactone yield. The supercritical carbon dioxide extraction showed higher selectivity than the conventional Soxhlet assisted extraction method. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  6. High-pressure liquid chromatography analysis of antibiotic susceptibility disks.

    PubMed Central

    Hagel, R B; Waysek, E H; Cort, W M

    1979-01-01

    The analysis of antibiotic susceptibility disks by high-pressure liquid chromatography (HPLC) was investigated. Methods are presented for the potency determination of mecillinam, ampicillin, carbenicillin, and cephalothin alone and in various combinations. Good agreement between HPLC and microbiological data is observed for potency determinations with recoveries of greater than 95%. Relative standard deviations of lower than 2% are recorded for each HPLC method. HPLC methods offer improved accuracy and greater precision when compared to the standard microbiological methods of analysis for susceptibility disks. PMID:507793

  7. Liquid Microjunction Surface Sampling Coupled with High-Pressure Liquid Chromatography-Electrospray Ionization-Mass Spectrometry for Analysis of Drugs and Metabolites in Whole-Body Thin Tissue Sections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kertesz, Vilmos; Van Berkel, Gary J

    2010-01-01

    In this work, a commercially available autosampler was adapted to perform direct liquid microjunction (LMJ) surface sampling followed by a high-pressure liquid chromatography (HPLC) separation of the extract components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the utility of coupling a separation with this direct liquid extraction based surface sampling approach, four different organs (brain, lung, kidney, and liver) from whole-body thin tissue sections of propranolol dosed and control mice were examined. The parent drug was observed in the chromatograms of the surface sampling extracts from all the organs of the dosed mouse examined. In addition, twomore » isomeric phase II metabolites of propranolol (an aliphatic and an aromatic hydroxypropranolol glucuronide) were observed in the chromatograms of the extracts from lung, kidney, and liver. Confirming the presence of one or the other or both of these glucuronides in the extract from the various organs was not possible without the separation. These drug and metabolite data obtained using the LMJ surface sampling/HPLC-MS method and the results achieved by analyzing similar samples by conventional extraction of the tissues and subsequent HPLC-MS analysis were consistent.« less

  8. Development of a new extraction technique and HPLC method for the analysis of non-psychoactive cannabinoids in fibre-type Cannabis sativa L. (hemp).

    PubMed

    Brighenti, Virginia; Pellati, Federica; Steinbach, Marleen; Maran, Davide; Benvenuti, Stefania

    2017-09-05

    The present work was aimed at the development and validation of a new, efficient and reliable technique for the analysis of the main non-psychoactive cannabinoids in fibre-type Cannabis sativa L. (hemp) inflorescences belonging to different varieties. This study was designed to identify samples with a high content of bioactive compounds, with a view to underscoring the importance of quality control in derived products as well. Different extraction methods, including dynamic maceration (DM), ultrasound-assisted extraction (UAE), microwave-assisted extraction (MAE) and supercritical-fluid extraction (SFE) were applied and compared in order to obtain a high yield of the target analytes from hemp. Dynamic maceration for 45min with ethanol (EtOH) at room temperature proved to be the most suitable technique for the extraction of cannabinoids in hemp samples. The analysis of the target analytes in hemp extracts was carried out by developing a new reversed-phase high-performance liquid chromatography (HPLC) method coupled with diode array (UV/DAD) and electrospray ionization-mass spectrometry (ESI-MS) detection, by using an ion trap mass analyser. An Ascentis Express C 18 column (150mm×3.0mm I.D., 2.7μm) was selected for the HPLC analysis, with a mobile phase composed of 0.1% formic acid in both water and acetonitrile, under gradient elution. The application of the fused-core technology allowed us to obtain a significant improvement of the HPLC performance compared with that of conventional particulate stationary phases, with a shorter analysis time and a remarkable reduction of solvent usage. The analytical method optimized in this study was fully validated to show compliance with international requirements. Furthermore, it was applied to the characterization of nine hemp samples and six hemp-based pharmaceutical products. As such, it was demonstrated to be a very useful tool for the analysis of cannabinoids in both the plant material and its derivatives for pharmaceutical and nutraceutical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. An analysis method for flavan-3-ols using high performance liquid chromatography coupled with a fluorescence detector.

    PubMed

    Wang, Liuqing; Yamashita, Yoko; Saito, Akiko; Ashida, Hitoshi

    2017-07-01

    Procyanidins belong to a family of flavan-3-ols, which consist of monomers, (+)-catechin and (-)-epicatechin, and their oligomers and polymers, and are distributed in many plant-derived foods. Procyanidins are reported to have many beneficial physiological activities, such as antihypertensive and anticancer effects. However, the bioavailability of procyanidins is not well understood owing to a lack of convenient and high-sensitive analysis methods. The aim of this study was to develop an improved method for determining procyanidin content in both food materials and biological samples. High performance liquid chromatography (HPLC) coupled with a fluorescence detector was used in this study. The limits of detection (LODs) of (+)-catechin, (-)-epicatechin, procyanidin B2, procyanidin C1, and cinnamtannin A2 were 3.0×10 -3  ng, 4.0×10 -3  ng, 14.0×10 -3  ng, 18.5×10 -3  ng, and 23.0×10 -3  ng, respectively; the limits of quantification (LOQs) were 10.0×10 -3  ng, 29.0×10 -3  ng, 28.5×10 -3  ng, 54.1×10 -3  ng, and 115.0×10 -3  ng, respectively. The LOD and LOQ values indicated that the sensitivity of the fluorescence detector method was around 1000 times higher than that of conventional HPLC coupled with a UV-detector. We applied the developed method to measure procyanidins in black soybean seed coat extract (BE) prepared from soybeans grown under three different fertilization conditions, namely, conventional farming, basal manure application, and intertillage. The amount of flavan-3-ols in these BEs decreased in the order intertillage > basal manure application > conventional farming. Commercially available BE was orally administered to mice at a dose of 250 mg/kg body weight, and we measured the blood flavan-3-ol content. Data from plasma analysis indicated that up to the tetramer oligomerization, procyanidins were detectable and flavan-3-ols mainly existed in conjugated forms in the plasma. In conclusion, we developed a highly sensitive and convenient analytical method for the analysis of flavan-3-ols, and applied this technique to investigate the bioavailability of flavan-3-ols in biological samples and to measure flavan-3-ol content in food material and plants. Copyright © 2017. Published by Elsevier B.V.

  10. Multidimensional Separation of Natural Products Using Liquid Chromatography Coupled to Hadamard Transform Ion Mobility Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Liu, Wenjie; Zhang, Xing; Knochenmuss, Richard; Siems, William F.; Hill, Herbert H.

    2016-05-01

    A high performance liquid chromatograph (HPLC)was interfaced to an atmospheric drift tube ion mobility time of flight mass spectrometry. The power of multidimensional separation was demonstrated using chili pepper extracts. The ambient pressure drift tube ion mobility provided high resolving powers up to 166 for the HPLC eluent. With implementation of Hadamard transform (HT), the duty cycle for the ion mobility drift tube was increased from less than 1% to 50%, and the ion transmission efficiency was improved by over 200 times compared with pulsed mode, improving signal to noise ratio 10 times. HT ion mobility and TOF mass spectrometry provide an additional dimension of separation for complex samples without increasing the analysis time compared with conventional HPLC.

  11. Microwave-assisted extraction and a new determination method for total steroid saponins from Dioscorea zingiberensis C.H. Wright.

    PubMed

    Ren, Yao; Chen, Yu; Hu, Bohan; Wu, Hui; Lai, Furao; Li, Xiaofeng

    2015-12-01

    An efficient microwave-assisted extraction (MAE) technique was applied to isolate total steroid saponins from Dioscorea zingiberensis C.H. Wright (DZW). The optimal extracting conditions were established as 75% ethanol as solvent, ratio of solid/liquid 1:20 (g/ml), temperature 75 °C, irradiation power 600 W and three extraction cycles of 6 min each. Scanning electron microscopy (SEM) images of DZW processed by four different extractions provided visual evidence of the disruption effect on DZW. Diosgenin was quantified by HPLC and examined further by LC-ESI/MS after acid hydrolysis. Total steroid saponins were calculated using diosgenin from total steroid saponins. The MAE procedure was optimized, validated and compared with other conventional extraction processes. This report provides a convenient technology for the extraction and quantification of total saponins of DZW combining MAE with HPLC and LC-ESI/MS for the first time. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Supercritical fluid chromatography for GMP analysis in support of pharmaceutical development and manufacturing activities.

    PubMed

    Hicks, Michael B; Regalado, Erik L; Tan, Feng; Gong, Xiaoyi; Welch, Christopher J

    2016-01-05

    Supercritical fluid chromatography (SFC) has long been a preferred method for enantiopurity analysis in support of pharmaceutical discovery and development, but implementation of the technique in regulated GMP laboratories has been somewhat slow, owing to limitations in instrument sensitivity, reproducibility, accuracy and robustness. In recent years, commercialization of next generation analytical SFC instrumentation has addressed previous shortcomings, making the technique better suited for GMP analysis. In this study we investigate the use of modern SFC for enantiopurity analysis of several pharmaceutical intermediates and compare the results with the conventional HPLC approaches historically used for analysis in a GMP setting. The findings clearly illustrate that modern SFC now exhibits improved precision, reproducibility, accuracy and robustness; also providing superior resolution and peak capacity compared to HPLC. Based on these findings, the use of modern chiral SFC is recommended for GMP studies of stereochemistry in pharmaceutical development and manufacturing. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Physiologically Relevant Changes in Serotonin Resolved by Fast Microdialysis

    PubMed Central

    2013-01-01

    Online microdialysis is a sampling and detection method that enables continuous interrogation of extracellular molecules in freely moving subjects under behaviorally relevant conditions. A majority of recent publications using brain microdialysis in rodents report sample collection times of 20–30 min. These long sampling times are due, in part, to limitations in the detection sensitivity of high performance liquid chromatography (HPLC). By optimizing separation and detection conditions, we decreased the retention time of serotonin to 2.5 min and the detection threshold to 0.8 fmol. Sampling times were consequently reduced from 20 to 3 min per sample for online detection of serotonin (and dopamine) in brain dialysates using a commercial HPLC system. We developed a strategy to collect and to analyze dialysate samples continuously from two animals in tandem using the same instrument. Improvements in temporal resolution enabled elucidation of rapid changes in extracellular serotonin levels associated with mild stress and circadian rhythms. These dynamics would be difficult or impossible to differentiate using conventional microdialysis sampling rates. PMID:23614776

  14. Bearberry identification by a multidisciplinary study on commercial raw materials.

    PubMed

    Gallo, Francesca Romana; Multari, Giuseppina; Pagliuca, Giordana; Panusa, Alessia; Palazzino, Giovanna; Giambenedetti, Massimo; Petitto, Valentina; Nicoletti, Marcello

    2013-04-01

    Herbal species different from the official bearberry, Arctostaphylos uva-ursi, are sold through conventional markets and also through non-controlled Internet websites, putting consumer safety at risk owing to the lack of quality control. Recently, Arctostaphylos pungens has become one of the most used species as a raw material for herbal medicines and dietary supplements in the place of official bearberry, a plant used for the treatment of various urinary disorders. A fingerprint identification based on an integrated application of different analytical techniques (HPTLC, NMR, HPLC-DAD and LC-ESI-MS) is here described to distinguish A. uva-ursi from A. pungens. The HPTLC and HPLC-DAD fingerprints resulted the simplest methods to differentiate the two species, whereas LC-ESI-MS was more useful to quantify arbutin, the main component of bearberry, and to evaluate its different content in the two species. This multidisciplinary study showed for the first time a specific phytochemical fingerprint of the new species A. pungens.

  15. Development and validation of micellar liquid chromatographic methods for the determination of antibiotics in different matrixes.

    PubMed

    Rambla-Alegre, Maria; Esteve-Romero, Josep; Carda-Broch, Samuel

    2011-01-01

    Antibiotics are the most important bioactive and chemotherapeutic compounds to be produced by microbiological synthesis, and they have proved their worth in a variety of fields, such as medicinal chemistry, agriculture, and the food industry. Interest in antibiotics has grown in parallel with an increasingly high degree of productivity in the field of analytical applications. Therefore, it is necessary to develop chromatographic procedures capable of determining various drugs simultaneously in the shortest possible time. Micellar liquid chromatography (MLC) is an RP-HPLC technique that offers advantages over conventional HPLC as far as sample preparation, selectivity, and versatility are concerned. Its main advantage is that samples can be injected directly into the chromatographic system with no previous preparation step. This paper mainly focuses on the results of the authors' own recent research and reports the chromatographic conditions for determination of various antibiotics (penicillins, quinolones, and sulfonamides) in different matrixes (pharmaceuticals, biological fluids, and food). The work of other authors on MLC-based antibiotic determination has been included.

  16. Methods of analysis by the U.S. Geological Survey Organic Geochemistry Research Group; determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry

    USGS Publications Warehouse

    Zimmerman, L.R.; Hostetler, K.A.; Thurman, E.M.

    2000-01-01

    Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: acetochlor ethanesulfonic acid (ESA), acetochlor oxanilic acid (OXA), alachlor ESA, alachlor OXA, metolachlor ESA, and metolachlor OXA. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The mean HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.50, and 2.0 mg/L (micrograms per liter) ranged from 84 to 112 percent, with relative standard deviations of 18 percent or less. The mean HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.20, and 2.0 mg/L ranged from 81 to 125 percent, with relative standard deviations of 20 percent or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 mg/L, whereas the LOQ using the HPLC/MS method was 0.05 mg/L. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water.

  17. A novel approach for quantitation of nonderivatized sialic acid in protein therapeutics using hydrophilic interaction chromatographic separation and nano quantity analyte detection.

    PubMed

    Chemmalil, Letha; Suravajjala, Sreekanth; See, Kate; Jordan, Eric; Furtado, Marsha; Sun, Chong; Hosselet, Stephen

    2015-01-01

    This paper describes a novel approach for the quantitation of nonderivatized sialic acid in glycoproteins, separated by hydrophilic interaction chromatography, and detection by Nano Quantity Analyte Detector (NQAD). The detection technique of NQAD is based on measuring change in the size of dry aerosol and converting the particle count rate into chromatographic output signal. NQAD detector is suitable for the detection of sialic acid, which lacks sufficiently active chromophore or fluorophore. The water condensation particle counting technology allows the analyte to be enlarged using water vapor to provide highest sensitivity. Derivatization-free analysis of glycoproteins using HPLC/NQAD method with PolyGLYCOPLEX™ amide column is well correlated with HPLC method with precolumn derivatization using 1, 2-diamino-4, 5-methylenedioxybenzene (DMB) as well as the Dionex-based high-pH anion-exchange chromatography (or ion chromatography) with pulsed amperometric detection (HPAEC-PAD). With the elimination of derivatization step, HPLC/NQAD method is more efficient than HPLC/DMB method. HPLC/NQAD method is more reproducible than HPAEC-PAD method as HPAEC-PAD method suffers high variability because of electrode fouling during analysis. Overall, HPLC/NQAD method offers broad linear dynamic range as well as excellent precision, accuracy, repeatability, reliability, and ease of use, with acceptable comparability to the commonly used HPAEC-PAD and HPLC/DMB methods. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  18. Chiral ligand-exchange high-performance liquid chromatography with copper (II)-L-phenylalanine complexes for separation of 3,4-dimethoxy-α-methylphenylalanine racemes.

    PubMed

    Jia, Dong-Xu; Ai, Zheng-Gui; Xue, Ya-Ping; Zheng, Yu-Guo

    2014-11-01

    L-3, 4-dimethoxy-α-methylphenylalanine (L-DMMD) is an important intermediate for the synthesis of 3-hydroxy-α-methyl-L-tyrosine (L-methyldopa). This paper describes an efficient, accurate, and low-priced method of high-performance liquid chromatography (HPLC) using chiral mobile phase and conventional C18 column to separate L-DMMD from its enantiomers. The effects of ligands, copper salts, organic modifiers, pHs of mobile phase, and temperatures on the retention factors (k') and selectivity (α) were evaluated to achieve optimal separation performance. Then, thermal analysis of the optimal separation conditions was investigated as well. It was confirmed that the optimal mobile phase was composed of 20 % (v/v) methanol, 8 mM L-phenylalanine (L-Phe), and 4 mM cupric sulfate in water of pH 3.2, and the column temperature was set at 20 °C. Baseline separation of two enantiomers could be obtained through the conventional C18 column with a resolution (R) of 3.18 in less than 18 min. Thermodynamic data (∆∆H and ∆∆S) obtained by Van't Hoff plots revealed the chiral separation was an enthalpy-controlled process. To the best of our knowledge, this is the first report regarding the enantioseparation of DMMD by chiral ligand-exchange HPLC.

  19. Selective Detection of Peptide-Oligonucleotide Heteroconjugates Utilizing Capillary HPLC-ICPMS

    NASA Astrophysics Data System (ADS)

    Catron, Brittany; Caruso, Joseph A.; Limbach, Patrick A.

    2012-06-01

    A method for the selective detection and quantification of peptide:oligonucleotide heteroconjugates, such as those generated by protein:nucleic acid cross-links, using capillary reversed-phase high performance liquid chromatography (cap-RPHPLC) coupled with inductively coupled plasma mass spectrometry detection (ICPMS) is described. The selective detection of phosphorus as 31P+, the only natural isotope, in peptide-oligonucleotide heteroconjugates is enabled by the elemental detection capabilities of the ICPMS. Mobile phase conditions that allow separation of heteroconjugates while maintaining ICPMS compatibility were investigated. We found that trifluoroacetic acid (TFA) mobile phases, used in conventional peptide separations, and hexafluoroisopropanol/triethylamine (HFIP/TEA) mobile phases, used in conventional oligonucleotide separations, both are compatible with ICPMS and enable heteroconjugate separation. The TFA-based separations yielded limits of detection (LOD) of ~40 ppb phosphorus, which is nearly seven times lower than the LOD for HFIP/TEA-based separations. Using the TFA mobile phase, 1-2 pmol of a model heteroconjugate were routinely separated and detected by this optimized capLC-ICPMS method.

  20. Rapid determination of polycyclic aromatic hydrocarbons in rainwater by liquid-liquid microextraction and LC with core-shell particles column and fluorescence detection.

    PubMed

    Vinci, Giuliana; Antonelli, Marta L; Preti, Raffaella

    2013-02-01

    Liquid-liquid microextraction coupled to LC with fluorescence detection for the determination of Environmental Protection Agency's 16 priority pollutant polycyclic aromatic hydrocarbons in rainwater has been developed. The optimization of the extraction method has involved several parameters, including the comparison between an ultrasonic bath and a magnetic stirrer as extractant apparatus, the choice of the extractant solvent, and the optimization of the extraction time. Liquid-liquid microextraction gave good results in terms of recoveries (from 73.6 to 102.8% in rainwater) and repeatability, with a very simple procedure and low solvent consumption. The reported chromatographic method uses a Core-Shell technology column, with particle size <3 μm instead of classical 5-μm particles column. The resulting backpressure was below 300 bar, allowing the use of a conventional HPLC system rather than the more expensive ultrahigh performance LC (UHPLC). An average decrease of 59% in run time and 75% in eluent consumption has been obtained, compared to classical HPLC methods, keeping good separation, sensitivity, and repeatability. The proposed conditions were successfully applied to the determinations of polycyclic aromatic hydrocarbons in genuine rainwater samples. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Use of biological fluids for the rapid diagnosis of potentially lethal inherited disorders of human purine and pyrimidine metabolism.

    PubMed

    Morris, G S; Simmonds, H A; Davies, P M

    1986-06-01

    Inherited purine and pyrimidine disorders may be associated with serious, sometimes life-threatening consequences. Early and accurate diagnosis is essential. Difficulties encountered when using existing high pressure liquid chromatographic (HPLC) methods led to the development of an improved method based on prior fractionation of urine. The advantages are as follows. 1. Production of fingerprints demonstrating altered urinary excretion patterns characteristic of any one of ten different disorders, in 30 minutes. 2. Positive identification and quantification by comparison with established methods (using conventional chromatography, electrophoresis and UV spectrophotometry) in addition to specific retention times and characteristic UV absorbance ratios at two separate wavelengths (245 and 280 nm) by HPLC. 3. Direct analysis of all the purines and pyrimidines normally found in human body fluids as well as identification of abnormal compounds. 4. Short time between successive analyses while maintaining excellent resolution between compounds of interest and column longevity. 5. Improved separation of the different adenine-based compounds encountered in some disorders, plus demonstration of potential interference by dietary or drug metabolites. 6. Applicability to the monitoring of therapy involving a variety of different purine and pyrimidine analogues. Particular attention should be paid to sample preparation. Plasma profiles will confirm the diagnosis in some, but not all, of these disorders.

  2. Comparison of UPLC and HPLC methods for determination of vitamin C.

    PubMed

    Klimczak, Inga; Gliszczyńska-Świgło, Anna

    2015-05-15

    Ultra performance liquid chromatography (UPLC) and high-performance liquid chromatography (HPLC) methods for determination of ascorbic acid (AA) and total AA (TAA) contents (as the sum of AA and dehydroascorbic acid (DHAA) after its reduction to AA) in fruit beverages and in pharmaceutical preparations were compared. Both methods are rapid: total time of analysis was 15 and 6 min for HPLC and UPLC methods, respectively. The methods were validated in terms of linearity, instrument precision, limits of detection (LOD) and quantification (LOQ), accuracy and recovery. Intra- and inter-day instrument precisions for fruit juices, expressed as RSD, were 2.2% and 2.4% for HPLC, respectively, and 1.7% and 1.9% for UPLC, respectively. For vitamin C tablets, inter- and intra-day precisions were 0.4% and 0.5%, respectively (HPLC), and 0.5% and 0.3%, respectively (UPLC). Both methods were sensitive: LOD was 0.049 μg/mL for HPLC and 0.024 μg/mL for UPLC while LOQs were 0.149 and 0.073 μg/mL for HPLC and UPLC, respectively. These methods could be useful in the routine qualitative and quantitative analysis of AA or TAA in pharmaceutical preparations or fruit beverages. However, UPLC method is more sensitive, faster and consumes less eluent. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Cluster analysis of commercial samples of Bauhinia spp. using HPLC-UV/PDA and MCR-ALS/PCA without peak alignment procedure.

    PubMed

    Ardila, Jorge Armando; Funari, Cristiano Soleo; Andrade, André Marques; Cavalheiro, Alberto José; Carneiro, Renato Lajarim

    2015-01-01

    Bauhinia forficata Link. is recognised by the Brazilian Health Ministry as a treatment of hypoglycemia and diabetes. Analytical methods are useful to assess the plant identity due the similarities found in plants from Bauhinia spp. HPLC-UV/PDA in combination with chemometric tools is an alternative widely used and suitable for authentication of plant material, however, the shifts of retention times for similar compounds in different samples is a problem. To perform comparisons between the authentic medicinal plant (Bauhinia forficata Link.) and samples commercially available in drugstores claiming to be "Bauhinia spp. to treat diabetes" and to evaluate the performance of multivariate curve resolution - alternating least squares (MCR-ALS) associated to principal component analysis (PCA) when compared to pure PCA. HPLC-UV/PDA data obtained from extracts of leaves were evaluated employing a combination of MCR-ALS and PCA, which allowed the use of the full chromatographic and spectrometric information without the need of peak alignment procedures. The use of MCR-ALS/PCA showed better results than the conventional PCA using only one wavelength. Only two of nine commercial samples presented characteristics similar to the authentic Bauhinia forficata spp., considering the full HPLC-UV/PDA data. The combination of MCR-ALS and PCA is very useful when applied to a group of samples where a general alignment procedure could not be applied due to the different chromatographic profiles. This work also demonstrates the need of more strict control from the health authorities regarding herbal products available on the market. Copyright © 2015 John Wiley & Sons, Ltd.

  4. Development and validation of high-performance liquid chromatography and high-performance thin-layer chromatography methods for the quantification of khellin in Ammi visnaga seed

    PubMed Central

    Kamal, Abid; Khan, Washim; Ahmad, Sayeed; Ahmad, F. J.; Saleem, Kishwar

    2015-01-01

    Objective: The present study was used to design simple, accurate and sensitive reversed phase-high-performance liquid chromatography RP-HPLC and high-performance thin-layer chromatography (HPTLC) methods for the development of quantification of khellin present in the seeds of Ammi visnaga. Materials and Methods: RP-HPLC analysis was performed on a C18 column with methanol: Water (75: 25, v/v) as a mobile phase. The HPTLC method involved densitometric evaluation of khellin after resolving it on silica gel plate using ethyl acetate: Toluene: Formic acid (5.5:4.0:0.5, v/v/v) as a mobile phase. Results: The developed HPLC and HPTLC methods were validated for precision (interday, intraday and intersystem), robustness and accuracy, limit of detection and limit of quantification. The relationship between the concentration of standard solutions and the peak response was linear in both HPLC and HPTLC methods with the concentration range of 10–80 μg/mL in HPLC and 25–1,000 ng/spot in HPTLC for khellin. The % relative standard deviation values for method precision was found to be 0.63–1.97%, 0.62–2.05% in HPLC and HPTLC for khellin respectively. Accuracy of the method was checked by recovery studies conducted at three different concentration levels and the average percentage recovery was found to be 100.53% in HPLC and 100.08% in HPTLC for khellin. Conclusions: The developed HPLC and HPTLC methods for the quantification of khellin were found simple, precise, specific, sensitive and accurate which can be used for routine analysis and quality control of A. visnaga and several formulations containing it as an ingredient. PMID:26681890

  5. Determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry

    USGS Publications Warehouse

    Hostetler, K.A.; Thurman, E.M.

    2000-01-01

    Analytical methods using high-performance liquid chromatography-diode array detection (HPLC-DAD) and high-performance liquid chromatography/mass spectrometry (HPLC/MS) were developed for the analysis of the following chloroacetanilide herbicide metabolites in water: alachlor ethanesulfonic acid (ESA); alachlor oxanilic acid; acetochlor ESA; acetochlor oxanilic acid; metolachlor ESA; and metolachlor oxanilic acid. Good precision and accuracy were demonstrated for both the HPLC-DAD and HPLC/MS methods in reagent water, surface water, and ground water. The average HPLC-DAD recoveries of the chloroacetanilide herbicide metabolites from water samples spiked at 0.25, 0.5 and 2.0 ??g/l ranged from 84 to 112%, with relative standard deviations of 18% or less. The average HPLC/MS recoveries of the metabolites from water samples spiked at 0.05, 0.2 and 2.0 ??g/l ranged from 81 to 118%, with relative standard deviations of 20% or less. The limit of quantitation (LOQ) for all metabolites using the HPLC-DAD method was 0.20 ??g/l, whereas the LOQ using the HPLC/MS method was at 0.05 ??g/l. These metabolite-determination methods are valuable for acquiring information about water quality and the fate and transport of the parent chloroacetanilide herbicides in water. Copyright (C) 2000 Elsevier Science B.V.

  6. Development and validation of a single robust HPLC method for the characterization of a pharmaceutical starting material and impurities from three suppliers using three separate synthetic routes.

    PubMed

    Sheldon, E M; Downar, J B

    2000-08-15

    Novel approaches to the development of analytical procedures for monitoring incoming starting material in support of chemical/pharmaceutical processes are described. High technology solutions were utilized for timely process development and preparation of high quality clinical supplies. A single robust HPLC method was developed and characterized for the analysis of the key starting material from three suppliers. Each supplier used a different process for the preparation of this material and, therefore, each suppliers' material exhibited a unique impurity profile. The HPLC method utilized standard techniques acceptable for release testing in a QC/manufacturing environment. An automated experimental design protocol was used to characterize the robustness of the HPLC method. The method was evaluated for linearity, limit of quantitation, solution stability, and precision of replicate injections. An LC-MS method that emulated the release HPLC method was developed and the identities of impurities were mapped between the two methods.

  7. HPLC-DAD-MS identification of bioactive secondary metabolites from Ferula communis roots.

    PubMed

    Arnoldi, Lolita; Ballero, Mauro; Fuzzati, Nicola; Maxia, Andrea; Mercalli, Enrico; Pagni, Luca

    2004-06-01

    A simple HPLC method was developed to distinguish between 'poisonous' and 'non-poisonous' chemotypes of Ferula communis. The method was performed on a C8 reverse phase analytical column using a binary eluent (aqueous TFA 0.01%-TFA 0.01% in acetonitrile) under gradient condition. The two chemotypes showed different fingerprints. The identification of five coumarins and eleven daucane derivatives by HPLC-diode array detection (HPLC-DAD) and HPLC-MS is described. A coumarin, not yet described, was detected. Copyright 2004 Elsevier B.V.

  8. Spectroscopic characterization and quantitative determination of atorvastatin calcium impurities by novel HPLC method

    NASA Astrophysics Data System (ADS)

    Gupta, Lokesh Kumar

    2012-11-01

    Seven process related impurities were identified by LC-MS in the atorvastatin calcium drug substance. These impurities were identified by LC-MS. The structure of impurities was confirmed by modern spectroscopic techniques like 1H NMR and IR and physicochemical studies conducted by using synthesized authentic reference compounds. The synthesized reference samples of the impurity compounds were used for the quantitative HPLC determination. These impurities were detected by newly developed gradient, reverse phase high performance liquid chromatographic (HPLC) method. The system suitability of HPLC analysis established the validity of the separation. The analytical method was validated according to International Conference of Harmonization (ICH) with respect to specificity, precision, accuracy, linearity, robustness and stability of analytical solutions to demonstrate the power of newly developed HPLC method.

  9. Environmentally evaluated HPLC-ELSD method to monitor enzymatic synthesis of a non-ionic surfactant.

    PubMed

    Gaber, Yasser; Akerman, Cecilia Orellana; Hatti-Kaul, Rajni

    2014-01-01

    N-Lauroyl-N-methylglucamide is a biodegradable surfactant derived from renewable resources. In an earlier study, we presented an enzymatic solvent-free method for synthesis of this compound. In the present report, the HPLC method developed to follow the reaction between lauric acid/methyl laurate and N-methyl glucamine (MEG) and its environmental assessment are described. Use of ultraviolet (UV) absorption or refractive index (RI) detectors did not allow the detection of N-methyl glucamine (MEG). With Evaporative light scattering detector ELSD, it was possible to apply a gradient elution, and detect MEG with a limit of detection, LOD = 0.12 μg. A good separation of the peaks: MEG, lauric acid, product (amide) and by-product (amide-ester) was achieved with the gradient program with a run time of 40 min. The setting of ELSD detector was optimized using methyl laurate as the analyte. LC-MS/MS was used to confirm the amide and amide-ester peaks. We evaluated the greenness of the developed method using the freely available software HPLC-Environmental Assessment Tool (HPLC-EAT) and the method got a scoring of 73 HPLC-EAT units, implying that the analytical procedure was more environmentally benign compared to some other methods reported in literature whose HPLC-EAT values scored up to 182. Use of ELSD detector allowed the detection and quantification of the substrates and the reaction products of enzymatic synthesis of the surfactant, N-lauroyl-N-methylglucamide. The developed HPLC method has acceptable environmental profile based on HPLC-EAT evaluation.

  10. Environmentally evaluated HPLC-ELSD method to monitor enzymatic synthesis of a non-ionic surfactant

    PubMed Central

    2014-01-01

    Background N-Lauroyl-N-methylglucamide is a biodegradable surfactant derived from renewable resources. In an earlier study, we presented an enzymatic solvent-free method for synthesis of this compound. In the present report, the HPLC method developed to follow the reaction between lauric acid/methyl laurate and N-methyl glucamine (MEG) and its environmental assessment are described. Results Use of ultraviolet (UV) absorption or refractive index (RI) detectors did not allow the detection of N-methyl glucamine (MEG). With Evaporative light scattering detector ELSD, it was possible to apply a gradient elution, and detect MEG with a limit of detection, LOD = 0.12 μg. A good separation of the peaks: MEG, lauric acid, product (amide) and by-product (amide-ester) was achieved with the gradient program with a run time of 40 min. The setting of ELSD detector was optimized using methyl laurate as the analyte. LC-MS/MS was used to confirm the amide and amide-ester peaks. We evaluated the greenness of the developed method using the freely available software HPLC-Environmental Assessment Tool (HPLC-EAT) and the method got a scoring of 73 HPLC-EAT units, implying that the analytical procedure was more environmentally benign compared to some other methods reported in literature whose HPLC-EAT values scored up to 182. Conclusion Use of ELSD detector allowed the detection and quantification of the substrates and the reaction products of enzymatic synthesis of the surfactant, N-lauroyl-N-methylglucamide. The developed HPLC method has acceptable environmental profile based on HPLC-EAT evaluation. PMID:24914404

  11. Simultaneous determination of chromones and coumarins in Radix Saposhnikoviae by high performance liquid chromatography with diode array and tandem mass detectors.

    PubMed

    Kim, Min Kyung; Yang, Dong-Hyug; Jung, Mihye; Jung, Eun Ha; Eom, Han Young; Suh, Joon Hyuk; Min, Jung Won; Kim, Unyong; Min, Hyeyoung; Kim, Jinwoong; Han, Sang Beom

    2011-09-16

    Methods using high performance liquid chromatography with diode array detection (HPLC-DAD) and tandem mass spectrometry (HPLC-MS/MS) were developed and validated for the simultaneous determination of 5 chromones and 6 coumarins: prim-O-glucosylcimifugin (1), cimifugin (2), nodakenin (3), 4'-O-β-d-glucosyl-5-O-methylvisamminol (4), sec-O-glucosylhamaudol (5), psoralen (6), bergapten (7), imperatorin (8), phellopterin (9), 3'-O-angeloylhamaudol (10) and anomalin (11), in Radix Saposhnikoviae. The separation conditions for HPLC-DAD were optimized using an Ascentis Express C18 (4.6 mm×100 mm, 2.7 μm particle size) fused-core column. The mobile phase was composed of 10% aqueous acetonitrile (A) and 90% acetonitrile (B) and the elution was performed under a gradient mode at a flow rate of 1.0 mL/min. The detection wavelength was set at 300 nm. The HPLC-DAD method yielded a base line separation of the 11 components in 50% methanol extract of Radix Saposhnikoviae with no interfering peaks detected. The HPLC-DAD method was validated in terms of linearity, accuracy and precision (intra- and inter-day), limit of quantification (LOQ), recovery, and robustness. Specific determination of the 11 components was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization (ESI) source. This HPLC-MS/MS method was also validated by determining the linearity, limit of quantification, accuracy, and precision. Quantification of the 11 components in 51 commercial Radix Saposhnikoviae samples was successfully performed using the developed HPLC-DAD method. The identity, batch-to-batch consistency, and authenticity of Radix Saposhnikoviae were successfully monitored by the proposed HPLC-DAD and HPLC-MS/MS methods. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. 76 FR 55329 - Receipt of Several Pesticide Petitions Filed for Residues of Pesticide Chemicals in or on Various...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-07

    ... (HPLC) method was validated for determination of dinotefuran, DN and UF in or on tomatoes and peppers... quantified after HPLC separation by tandem mass spectrometry (MS/MS) detection. Contact: Sidney Jackson, (703..., group 9 at 0.03 ppm. Adequate analytical methods (HPLC-fluorescence methods) are available for...

  13. Application of microscopy technique and high-performance liquid chromatography for quality assessment of the flower bud of Tussilago farfara L. (Kuandonghua)

    PubMed Central

    Li, Da; Liang, Li; Zhang, Jing; Kang, Tingguo

    2015-01-01

    Background: Quality control is one of the bottleneck problems limiting the application and development of traditional Chinese medicine (TCM). In recent years, microscopy and high-performance liquid chromatography (HPLC) techniques have been frequently applied in the quality control of TCM. However, studies combining conventional microscopy and HPLC techniques for the quality control of the flower bud of Tussilago farfara L. (Kuandonghua) have not been reported. Objective: This study was undertaken to evaluate the quality of the flower bud of T. farfara L. and to establish the relationships between the quantity of pollen grains and four main bioactive constituents: tussilagone, chlorogenic acid, rutin and isoquercitrin. Materials and Methods: In this study, microscopic examination was used to quantify microscopic characteristics of the flower bud of T. farfara L., and the chemical components were determined by HPLC. The data were analyzed by Statistical Package for the Social Sciences statistics software. Results: The results of the analysis showed that tussilagone, chlorogenic acid, rutin and isoquercitrin were significantly correlated with the quantity of pollen grains in the flower bud of T. farfara L. There is a positive correlation between them. From these results, it can be deduced that the flower bud of T. farfara L. with a greater quantity of pollen grains should be of better quality. Conclusion: The study showed that the established method can be helpful for evaluating the quality of the flower bud of T. farfara L. based on microscopic characteristic constants and chemical quantitation. PMID:26246737

  14. Electrodialytic in-line preconcentration for ionic solute analysis.

    PubMed

    Ohira, Shin-Ichi; Yamasaki, Takayuki; Koda, Takumi; Kodama, Yuko; Toda, Kei

    2018-04-01

    Preconcentration is an effective way to improve analytical sensitivity. Many types of methods are used for enrichment of ionic solute analytes. However, current methods are batchwise and include procedures such as trapping and elution. In this manuscript, we propose in-line electrodialytic enrichment of ionic solutes. The method can enrich ionic solutes within seconds by quantitative transfer of analytes from the sample solution to the acceptor solution under an electric field. Because of quantitative ion transfer, the enrichment factor (the ratio of the concentration in the sample and to that in the obtained acceptor solution) only depends on the flow rate ratio of the sample solution to the acceptor solution. The ratios of the concentrations and flow rates are equal for ratios up to 70, 20, and 70 for the tested ionic solutes of inorganic cations, inorganic anions, and heavy metal ions, respectively. The sensitivity of ionic solute determinations is also improved based on the enrichment factor. The method can also simultaneously achieve matrix isolation and enrichment. The method was successively applied to determine the concentrations of trace amounts of chloroacetic acids in tap water. The regulated concentration levels cannot be determined by conventional high-performance liquid chromatography with ultraviolet detection (HPLC-UV) without enrichment. However, enrichment with the present method is effective for determination of tap water quality by improving the limits of detection of HPLC-UV. The standard addition test with real tap water samples shows good recoveries (94.9-109.6%). Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Quality Analysis of Chlorogenic Acid and Hyperoside in Crataegi fructus

    PubMed Central

    Weon, Jin Bae; Jung, Youn Sik; Ma, Choong Je

    2016-01-01

    Background: Crataegi fructus is a herbal medicine for strong stomach, sterilization, and alcohol detoxification. Chlorogenic acid and hyperoside are the major compounds in Crataegi fructus. Objective: In this study, we established novel high-performance liquid chromatography (HPLC)-diode array detection analysis method of chlorogenic acid and hyperoside for quality control of Crataegi fructus. Materials and Methods: HPLC analysis was achieved on a reverse-phase C18 column (5 μm, 4.6 mm × 250 mm) using water and acetonitrile as mobile phase with gradient system. The method was validated for linearity, precision, and accuracy. About 31 batches of Crataegi fructus samples collected from Korea and China were analyzed by using HPLC fingerprint of developed HPLC method. Then, the contents of chlorogenic acid and hyperoside were compared for quality evaluation of Crataegi fructus. Results: The results have shown that the average contents (w/w %) of chlorogenic acid and hyperoside in Crataegi fructus collected from Korea were 0.0438% and 0.0416%, respectively, and the average contents (w/w %) of 0.0399% and 0.0325%, respectively. Conclusion: In conclusion, established HPLC analysis method was stable and could provide efficient quality evaluation for monitoring of commercial Crataegi fructus. SUMMARY Quantitative analysis method of chlorogenic acid and hyperoside in Crataegi fructus is developed by high.performance liquid chromatography.(HPLC).diode array detectionEstablished HPLC analysis method is validated with linearity, precision, and accuracyThe developed method was successfully applied for quantitative analysis of Crataegi fructus sample collected from Korea and China. Abbreviations used: HPLC: High-performance liquid chromatography, GC: Gas chromatography, MS: Mass spectrometer, LOD: Limits of detection, LOQ: Limits of quantification, RSD: Relative standard deviation, RRT: Relative retention time, RPA: Relation peak area. PMID:27076744

  16. A simple high performance liquid chromatography method for analyzing paraquat in soil solution samples.

    PubMed

    Ouyang, Ying; Mansell, Robert S; Nkedi-Kizza, Peter

    2004-01-01

    A high performance liquid chromatography (HPLC) method with UV detection was developed to analyze paraquat (1,1'-dimethyl-4,4'-dipyridinium dichloride) herbicide content in soil solution samples. The analytical method was compared with the liquid scintillation counting (LSC) method using 14C-paraquat. Agreement obtained between the two methods was reasonable. However, the detection limit for paraquat analysis was 0.5 mg L(-1) by the HPLC method and 0.05 mg L(-1) by the LSC method. The LSC method was, therefore, 10 times more precise than the HPLC method for solution concentrations less than 1 mg L(-1). In spite of the high detection limit, the UC (nonradioactive) HPLC method provides an inexpensive and environmentally safe means for determining paraquat concentration in soil solution compared with the 14C-LSC method.

  17. Total chemical synthesis of proteins without HPLC purification† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c6sc01883a Click here for additional data file.

    PubMed Central

    Loibl, S. F.; Harpaz, Z.; Zitterbart, R.

    2016-01-01

    The total chemical synthesis of proteins is a tedious and time-consuming endeavour. The typical steps involve solid phase synthesis of peptide thioesters and cysteinyl peptides, native chemical ligation (NCL) in solution, desulfurization or removal of ligation auxiliaries in the case of extended NCL as well as many intermediary and final HPLC purification steps. With an aim to facilitate and improve the throughput of protein synthesis we developed the first method for the rapid chemical total on-resin synthesis of proteins that proceeds without a single HPLC-purification step. The method relies on the combination of three orthogonal protein tags that allow sequential immobilization (via the N-terminal and C-terminal ends), extended native chemical ligation and release reactions. The peptide fragments to be ligated are prepared by conventional solid phase synthesis and used as crude materials in the subsequent steps. An N-terminal His6 unit permits selective immobilization of the full length peptide thioester onto Ni-NTA agarose beads. The C-terminal peptide fragment carries a C-terminal peptide hydrazide and an N-terminal 2-mercapto-2-phenyl-ethyl ligation auxiliary, which serves as a reactivity tag for the full length peptide. As a result, only full length peptides, not truncation products, react in the subsequent on-bead extended NCL. After auxiliary removal the ligation product is liberated into solution upon treatment with mild acid, and is concomitantly captured by an aldehyde-modified resin. This step allows the removal of the most frequently observed by-product in NCL chemistry, i.e. the hydrolysed peptide thioester (which does not contain a C-terminal peptide hydrazide). Finally, the target protein is released with diluted hydrazine or acid. We applied the method in the synthesis of 46 to 126 amino acid long MUC1 proteins comprising 2–6 copies of a 20mer tandem repeat sequence. Only three days were required for the parallel synthesis of 9 MUC1 proteins which were obtained in 8–33% overall yield with 90–98% purity despite the omission of HPLC purification. PMID:28451120

  18. Regio- and stereospecific analysis of glycerolipids.

    PubMed

    Kuksis, Arnis; Itabashi, Yutaka

    2005-06-01

    In recent years researchers have recognized the potential value of comprehensive lipid profiling (lipidomics), which was invented and promoted by lipidologists who recognized the many valuable applications that grew out of the fields of DNA profiling (genomics) and protein profiling (proteonomics). Through lipid class-selective intrasource ionization and subsequent analysis of two-dimensional cross-peak intensities, the chemical identity and mass composition of individual molecular species of most lipid classes can now be determined in a chloroform extract. There remains, however, the necessity to distinguish the enantiomers and isobaric regioisomers resulting from enzymatic and chemical reactions, which conventional high performance liquid chromatography/mass spectrometry (HPLC/MS) has been slow to accommodate, and tandem MS unable to provide. While reversed-phase HPLC can separate regioisomers, normal-phase HPLC can resolve diastereomers, and chiral-phase HPLC can effect dramatic resolution of enantiomers, the full potential of the combined systems has seldom been exploited. The present chapter calls attention to both recent and earlier combinations of these methodologies with mass spectrometry, which allows the HPLC/ESI (electrospray ionization)-MS/MS separation and identification of enantiomeric diacylglycerols, triacylglycerols, and glycerophospholipids as well as their isobaric regioisomers. These developments permit further expansion of lipid profiling (lipidomics) and better understanding of lipid metabolism.

  19. Simultaneous determination of potassium guaiacolsulfonate, guaifenesin, diphenhydramine HCl and carbetapentane citrate in syrups by using HPLC-DAD coupled with partial least squares multivariate calibration.

    PubMed

    Dönmez, Ozlem Aksu; Aşçi, Bürge; Bozdoğan, Abdürrezzak; Sungur, Sidika

    2011-02-15

    A simple and rapid analytical procedure was proposed for the determination of chromatographic peaks by means of partial least squares multivariate calibration (PLS) of high-performance liquid chromatography with diode array detection (HPLC-DAD). The method is exemplified with analysis of quaternary mixtures of potassium guaiacolsulfonate (PG), guaifenesin (GU), diphenhydramine HCI (DP) and carbetapentane citrate (CP) in syrup preparations. In this method, the area does not need to be directly measured and predictions are more accurate. Though the chromatographic and spectral peaks of the analytes were heavily overlapped and interferents coeluted with the compounds studied, good recoveries of analytes could be obtained with HPLC-DAD coupled with PLS calibration. This method was tested by analyzing the synthetic mixture of PG, GU, DP and CP. As a comparison method, a classsical HPLC method was used. The proposed methods were applied to syrups samples containing four drugs and the obtained results were statistically compared with each other. Finally, the main advantage of HPLC-PLS method over the classical HPLC method tried to emphasized as the using of simple mobile phase, shorter analysis time and no use of internal standard and gradient elution. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Optimization of Robust HPLC Method for Quantitation of Ambroxol Hydrochloride and Roxithromycin Using a DoE Approach.

    PubMed

    Patel, Rashmin B; Patel, Nilay M; Patel, Mrunali R; Solanki, Ajay B

    2017-03-01

    The aim of this work was to develop and optimize a robust HPLC method for the separation and quantitation of ambroxol hydrochloride and roxithromycin utilizing Design of Experiment (DoE) approach. The Plackett-Burman design was used to assess the impact of independent variables (concentration of organic phase, mobile phase pH, flow rate and column temperature) on peak resolution, USP tailing and number of plates. A central composite design was utilized to evaluate the main, interaction, and quadratic effects of independent variables on the selected dependent variables. The optimized HPLC method was validated based on ICH Q2R1 guideline and was used to separate and quantify ambroxol hydrochloride and roxithromycin in tablet formulations. The findings showed that DoE approach could be effectively applied to optimize a robust HPLC method for quantification of ambroxol hydrochloride and roxithromycin in tablet formulations. Statistical comparison between results of proposed and reported HPLC method revealed no significant difference; indicating the ability of proposed HPLC method for analysis of ambroxol hydrochloride and roxithromycin in pharmaceutical formulations. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. A novel approach for the quantitation of carbohydrates in mash, wort, and beer with RP-HPLC using 1-naphthylamine for precolumn derivatization.

    PubMed

    Rakete, Stefan; Glomb, Marcus A

    2013-04-24

    A novel universal method for the determination of reducing mono-, di-, and oligosaccharides in complex matrices on RP-HPLC using 1-naphthylamine for precolumn derivatization with sodium cyanoborhydride was established to study changes in the carbohydrate profile during beer brewing. Fluorescence and mass spectrometric detection enabled very sensitive analyses of beer-relevant carbohydrates. Mass spectrometry additionally allowed the identification of the molecular weight and thereby the degree of polymerization of unknown carbohydrates. Thus, carbohydrates with up to 16 glucose units were detected. Comparison demonstrated that the novel method was superior to fluorophore-assisted carbohydrate electrophoresis (FACE). The results proved the HPLC method clearly to be more powerful in regard to sensitivity and resolution. Analogous to FACE, this method was designated fluorophore-assisted carbohydrate HPLC (FAC-HPLC).

  2. SFC-MS/MS as an orthogonal technique for improved screening of polar analytes in anti-doping control.

    PubMed

    Parr, Maria Kristina; Wuest, Bernhard; Naegele, Edgar; Joseph, Jan F; Wenzel, Maxi; Schmidt, Alexander H; Stanic, Mijo; de la Torre, Xavier; Botrè, Francesco

    2016-09-01

    HPLC is considered the method of choice for the separation of various classes of drugs. However, some analytes are still challenging as HPLC shows limited resolution capabilities for highly polar analytes as they interact insufficiently on conventional reversed-phase (RP) columns. Especially in combination with mass spectrometric detection, limitations apply for alterations of stationary phases. Some highly polar sympathomimetic drugs and their metabolites showed almost no retention on different RP columns. Their retention remains poor even on phenylhexyl phases that show different selectivity due to π-π interactions. Supercritical fluid chromatography (SFC) as an orthogonal separation technique to HPLC may help to overcome these issues. Selected polar drugs and metabolites were analyzed utilizing SFC separation. All compounds showed sharp peaks and good retention even for the very polar analytes, such as sulfoconjugates. Retention times and elution orders in SFC are different to both RP and HILIC separations as a result of the orthogonality. Short cycle times could be realized. As temperature and pressure strongly influence the polarity of supercritical fluids, precise regulation of temperature and backpressure is required for the stability of the retention times. As CO2 is the main constituent of the mobile phase in SFC, solvent consumption and solvent waste are considerably reduced. Graphical Abstract SFC-MS/MS vs. LC-MS/MS.

  3. Effect of /sup 60/Co-irradiation on penicillin G procaine in veterinary mastitis products

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsuji, K.; Goetz, J.F.; Vanmeter, W.

    The effect of /sup 60/Co-irradation on penicillin G procaine in a peanut oil-based veterinary mastitis product was examined by reversed-phase high-performance liquid chromatography (HPLC). The HPLC method is capable of separating and quantifiying procaine, penicillin G, and various degradation compounds. Values obtained by the HPLC method on the product irradiated and stored at various temperatures correlated well with those of the microbiological assay. No significant decrease in the procaine was detected even after 4.0-Mrad irradiation. The HPLC method is applicable for analysis of other beta-lactam antibiotics.

  4. High-performance liquid chromatography method for the determination of hydrogen peroxide present or released in teeth bleaching kits and hair cosmetic products.

    PubMed

    Gimeno, Pascal; Bousquet, Claudine; Lassu, Nelly; Maggio, Annie-Françoise; Civade, Corinne; Brenier, Charlotte; Lempereur, Laurent

    2015-03-25

    This manuscript presents an HPLC/UV method for the determination of hydrogen peroxide present or released in teeth bleaching products and hair products. The method is based on an oxidation of triphenylphosphine into triphenylphosphine oxide by hydrogen peroxide. Triphenylphosphine oxide formed is quantified by HPLC/UV. Validation data were obtained using the ISO 12787 standard approach, particularly adapted when it is not possible to make reconstituted sample matrices. For comparative purpose, hydrogen peroxide was also determined using ceric sulfate titrimetry for both types of products. For hair products, a cross validation of both ceric titrimetric method and HPLC/UV method using the cosmetic 82/434/EEC directive (official iodometric titration method) was performed. Results obtained for 6 commercialized teeth whitening products and 5 hair products point out similar hydrogen peroxide contain using either the HPLC/UV method or ceric sulfate titrimetric method. For hair products, results were similar to the hydrogen peroxide content using the cosmetic 82/434/EEC directive method and for the HPLC/UV method, mean recoveries obtained on spiked samples, using the ISO 12787 standard, ranges from 100% to 110% with a RSD<3.0%. To assess the analytical method proposed, the HPLC method was used to control 35 teeth bleaching products during a market survey and highlight for 5 products, hydrogen peroxide contents higher than the regulated limit. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Effects of low sulfur dioxide concentrations on bioactive compounds and antioxidant properties of Aglianico red wine.

    PubMed

    Gabriele, Morena; Gerardi, Chiara; Lucejko, Jeannette J; Longo, Vincenzo; Pucci, Laura; Domenici, Valentina

    2018-04-15

    This study analyzed the effect of low sulfur dioxide concentrations on the chromatic properties, phytochemical composition and antioxidant activity of Aglianico red wines with respect to wines produced from conventional winemaking. We determined the phytochemical composition by spectrophotometric methods and HPLC-DAD analysis and the in vitro antioxidant activity of different wine samples by the ORAC assay. The main important classes of fluorophore molecules in red wine were identified by Front-Face fluorescence spectroscopy, and the emission intensity trend was investigated at various sulfur dioxide concentrations. Lastly, we tested the effects of both conventional and low sulfite wines on ex vivo human erythrocytes under oxidative stimulus by the cellular antioxidant activity (CAA) assay and the hemolysis test. The addition of sulfur dioxide, which has well-known side effects, increased the content of certain bioactive components but did not raise the erythrocyte antioxidant capacity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Methods of Analysis by the U.S. Geological Survey Organic Geochemistry Research Group-Update and Additions to the Determination of Chloroacetanilide Herbicide Degradation Compounds in Water Using High-Performance Liquid Chromatography/Mass Spectrometry

    USGS Publications Warehouse

    Lee, E.A.; Kish, J.L.; Zimmerman, L.R.; Thurman, E.

    2001-01-01

    An analytical method using high-performance liquid chromatography/mass spectrometry (HPLC/MS) was developed by the U.S. Geological Survey in 1999 for the analysis of selected chloroacetanilide herbicide degradation compounds in water. These compounds were acetochlor ethane sulfonic acid (ESA), acetochlor oxanilic acid (OXA), alachlor ESA, alachlor OXA, metolachlor ESA, and metolachlor OXA. The HPLC/MS method was updated in 2000, and the method detection limits were modified accordingly. Four other degradation compounds also were added to the list of compounds that can be analyzed using HPLC/MS; these compounds were dimethenamid ESA, dimethenamid OXA, flufenacet ESA, and flufenacet OXA. Except for flufenacet OXA, good precision and accuracy were demonstrated for the updated HPLC/MS method in buffered reagent water, surface water, and ground water. The mean HPLC/MS recoveries of the degradation compounds from water samples spiked at 0.20 and 1.0 ?g/L (microgram per liter) ranged from 75 to 114 percent, with relative standard deviations of 15.8 percent or less for all compounds except flufenacet OXA, which had relative standard deviations ranging from 11.3 to 48.9 percent. Method detection levels (MDL's) using the updated HPLC/MS method varied from 0.009 to 0.045 ?g/L, with the flufenacet OXA MDL at 0.072 ?g/L. The updated HPLC/MS method is valuable for acquiring information about the fate and transport of the parent chloroacetanilide herbicides in water.

  7. Comparative evaluation of ibuprofen/beta-cyclodextrin complexes obtained by supercritical carbon dioxide and other conventional methods.

    PubMed

    Hussein, Khaled; Türk, Michael; Wahl, Martin A

    2007-03-01

    The preparation of drug/cyclodextrin complexes is a suitable method to improve the dissolution of poor soluble drugs. The efficacy of the Controlled Particle Deposition (CPD) as a new developed method to prepare these complexes in a single stage process using supercritical carbon dioxide is therefore compared with other conventional methods. Ibuprofen/beta-cyclodextrin complexes were prepared with different techniques and characterized using FTIR-ATR spectroscopy, powder X-ray diffractometry (PXRD), differential scanning calorimetry (DSC) and scanning electron microscopy (SEM). In addition, the influences of the processing technique on the drug content (HPLC) and the dissolution behavior were studied. Employing the CPD-process resulted in a drug content of 2.8+/-0.22 wt.% in the carrier. The material obtained by CPD showed an improved dissolution rate of ibuprofen at pH 5 compared with the pure drug and its physical mixture with beta-cyclodextrin. In addition CPD material displays the highest dissolution (93.5+/- 2.89% after 75 min) compared to material obtained by co-precipitation (61.3 +/-0.52%) or freeze-drying (90.6 +/-2.54%). This study presents the CPD-technique as a well suitable method to prepare a drug/beta-cyclodextrin complex with improved drug dissolution compared to the pure drug and materials obtained by other methods.

  8. Analysis of D3-,4-,5-phosphorylated phosphoinositides using HPLC.

    PubMed

    Munnik, Teun

    2013-01-01

    Detection of polyphosphoinositides (PPIs) is difficult due to their low chemical abundancy. This problem is further complicated by the fact that PPIs are present as various, distinct isomers, which are difficult, if not impossible, to separate by conventional thin layer chromatography (TLC) systems. PPIs in plants include PtdIns3P, PtdIns4P, PtdIns5P, PtdIns(3,5)P 2, and PtdIns(4,5)P 2. Here, a protocol is described analyzing plant PPIs using (32)P-orthophosphorus pre-labeled material. After extraction, lipids are deacylated and the resulting glycerophosphoinositol polyphosphates (GroPInsPs) separated by HPLC using a strong anion-exchange column and a shallow salt gradient. Alternatively, PPIs are first separated by TLC, the lipids reisolated, deacylated, and the GroPInsPs then separated by HPLC.

  9. Analysis of formononetin from black cohosh (Actaea racemosa).

    PubMed

    Jiang, B; Kronenberg, F; Balick, M J; Kennelly, E J

    2006-07-01

    Black cohosh has been widely used as an herbal medicine for the treatment of symptoms related to menopause in America and Europe during the past several decades, but the bioactive constituents are still unknown. Formononetin is an isoflavone with known estrogen-like activity. This compound was first reported to be isolated from black cohosh in 1985, but subsequent research in 2002 using HPLC-PDA and LC-MS revealed no evidence to show the presence of formononetin in 13 populations of American black cohosh. A more recent report published in 2004 claimed to detect formononetin in an extract of black cohosh rhizomes using a TLC-fluorescent densitometry method. To further resolve these conflicting reports, we analyzed black cohosh roots and rhizomes for the presence of formononetin, using a combined TLC, HPLC-PDA and LC-MS method. We examined both methanolic and aqueous methanolic black cohosh extracts by HPLC-PDA and LC-MS methods, and did not detect formononetin in any extracts. We further determined the limits of detection of formononetin by HPLC-PDA and LC-MS. Our experimental results indicated that the sensitivity and accuracy of the HPLC-PDA and LC-MS methods for the analysis of formononetin were slightly higher than those of the reported fluorescent method, suggesting that the HPLC-PDA and LC-MS methods were reliable for the analysis of formononetin from black cohosh. We also repeated the reported TLC method to concentrate two fractions from a modern black cohosh sample and an 86-year-old black cohosh sample, respectively, and then analyzed these two fractions for formononetin using the HPLC-PDA and LC-MS method instead of the fluorescent method. Formononetin was not detected by HPLC-PDA or LC-MS. From the results of the present study it is not reasonable to attribute the estrogen-like activity of black cohosh extracts to formononetin.

  10. COBALT-60 Gamma Irradiation of Shrimp.

    NASA Astrophysics Data System (ADS)

    Sullivan, Nancy L. B.

    Meta- and ortho-tyrosine were measured using high performance liquid chromatography (HPLC) in conjunction with electrochemical detection in shrimp irradiated using cobalt-60 gamma radiation in the absorbed dose range 0.8 to 6.0 kGy, in nonirradiated shrimp, and in bovine serum albumin (BSA) irradiated in dilute aqueous solution at 25.0 kGy. Ortho-tyrosine was measured in nonirradiated BSA. Para-, meta-, and ortho-tyrosine were measured using HPLC in conjunction with uv-absorption detection in dilute aqueous solutions of phenylalanine irradiated in the absorbed dose range 16.0 to 195.0 kGy. The measured yields of tyrosine isomers were approximately linear as a function of absorbed dose in shrimp, and in irradiated solutions of phenylalanine up to 37.0 kGy. The occurrence of meta- and ortho-tyrosine, which had formerly been considered unique radiolytic products, has not previously been reported in nonirradiated shrimp or BSA. The conventional hydrolyzation and analytical techniques used in the present study to measure meta- and ortho-tyrosine may provide the basis for a method to detect and determine the dose used in food irradiation.

  11. Optimization of supercritical fluid extraction and HPLC identification of wedelolactone from Wedelia calendulacea by orthogonal array design.

    PubMed

    Patil, Ajit A; Sachin, Bhusari S; Wakte, Pravin S; Shinde, Devanand B

    2014-11-01

    The purpose of this work is to provide a complete study of the influence of operational parameters of the supercritical carbon dioxide assisted extraction (SC CO2E) on yield of wedelolactone from Wedelia calendulacea Less., and to find an optimal combination of factors that maximize the wedelolactone yield. In order to determine the optimal combination of the four factors viz. operating pressure, temperature, modifier concentration and extraction time, a Taguchi experimental design approach was used: four variables (three levels) in L9 orthogonal array. Wedelolactone content was determined using validated HPLC methodology. Optimum extraction conditions were found to be as follows: extraction pressure, 25 MPa; temperature, 40 °C; modifier concentration, 10% and extraction time, 90 min. Optimum extraction conditions demonstrated wedelolactone yield of 8.01 ± 0.34 mg/100 g W. calendulacea Less. Pressure, temperature and time showed significant (p < 0.05) effect on the wedelolactone yield. The supercritical carbon dioxide extraction showed higher selectivity than the conventional Soxhlet assisted extraction method.

  12. Optimization of supercritical fluid extraction and HPLC identification of wedelolactone from Wedelia calendulacea by orthogonal array design

    PubMed Central

    Patil, Ajit A.; Sachin, Bhusari S.; Wakte, Pravin S.; Shinde, Devanand B.

    2013-01-01

    The purpose of this work is to provide a complete study of the influence of operational parameters of the supercritical carbon dioxide assisted extraction (SC CO2E) on yield of wedelolactone from Wedelia calendulacea Less., and to find an optimal combination of factors that maximize the wedelolactone yield. In order to determine the optimal combination of the four factors viz. operating pressure, temperature, modifier concentration and extraction time, a Taguchi experimental design approach was used: four variables (three levels) in L9 orthogonal array. Wedelolactone content was determined using validated HPLC methodology. Optimum extraction conditions were found to be as follows: extraction pressure, 25 MPa; temperature, 40 °C; modifier concentration, 10% and extraction time, 90 min. Optimum extraction conditions demonstrated wedelolactone yield of 8.01 ± 0.34 mg/100 g W. calendulacea Less. Pressure, temperature and time showed significant (p < 0.05) effect on the wedelolactone yield. The supercritical carbon dioxide extraction showed higher selectivity than the conventional Soxhlet assisted extraction method. PMID:25687584

  13. Quantification of quercetin glycosides in 6 onion cultivars and comparisons of hydrolysis-HPLC and spectrophotometric methods in measuring total quercetin concentrations.

    PubMed

    Yoo, Kil Sun; Lee, Eun Jin; Patil, Bhimanagouda S

    2010-03-01

    This study was performed to purify and quantify quercetin glycosides (QG) and aglycone (free) quercetin (Q) in 6 selected onion cultivars and to compare analytical approaches based on high-performance liquid chromatography (HPLC) and spectrophotometry for the quantification of total quercetin (TQ) concentrations. Individual mono- and di-glycoside Q compounds were purified using a semipreparative HPLC and identified by comparing spectral data and by confirming corresponding peaks of QG and Q after incomplete enzyme-hydrolysis. Purified QG were quantified as Q by enzyme-hydrolysis/HPLC. TQ concentrations obtained from 20 onion bulbs with enzyme-hydrolysis/HPLC, no-hydrolysis/HPLC, and a spectrophotometric method without prior hydrolysis were significantly correlated (r(2)= 0.99) and were about 15% higher, identical, or 10% less than those concentrations by a standard acid-hydrolysis/HPLC method, respectively. During enzyme-hydrolysis of onion extracts, progressive reduction of the QG and formation of the corresponding mono-glycosides and Q were monitored using an analytical HPLC. TQ ranged from 83 to 330 microg/g F.W. in 6 selected cultivars of long-day or short-day onions. Q3,4'G and Q4'G were the 2 major compounds and comprised approximately between 94% and 97% of TQ in onions.

  14. Carotenoids and Retinoids: Nomenclature, Chemistry, and Analysis.

    PubMed

    Harrison, Earl H; Curley, Robert W

    Carotenoids are polyenes synthesized in plants and certain microorganisms and are pigments used by plants and animals in various physiological processes. Some of the over 600 known carotenoids are capable of metabolic conversion to the essential nutrient vitamin A (retinol) in higher animals. Vitamin A also gives rise to a number of other metabolites which, along with their analogs, are known as retinoids. To facilitate discussion about these important molecules, a nomenclature is required to identify specific substances. The generally accepted rules for naming these important molecules have been agreed to by various Commissions of the International Union of Pure and Applied Chemistry and International Union of Biochemistry. These naming conventions are explained along with comparisons to more systematic naming rules that apply for these organic chemicals. Identification of the carotenoids and retinoids has been advanced by their chemical syntheses, and here, both classical and modern methods for synthesis of these molecules, as well as their analogs, are described. Because of their importance in biological systems, sensitive methods for the detection and quantification of these compounds from various sources have been essential. Early analyses that relied on liquid adsorption and partition chromatography have given way to high-performance liquid chromatography (HPLC) coupled with various detection methods. The development of HPLC coupled to mass spectrometry, particularly LC/MS-MS with Multiple Reaction Monitoring, has resulted in the greatest sensitivity and specificity in these analyses.

  15. 76 FR 38033 - Cloquintocet-mexyl; Pesticide Tolerances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-29

    ... enforcement methods are the High Performance Liquid Chromatography with Ultraviolet Detection (HPLC/UV) method REM 138.01 for determination of cloquintocet-mexyl (parent) and the HPLC/UV Method REM 138.10 for...

  16. Immunoaffinity column as clean-up tool for determination of trace amounts of microcystins in tap water.

    PubMed

    Tsutsumi, T; Nagata, S; Hasegawa, A; Ueno, Y

    2000-07-01

    Trace amounts of microcystins (MCs) in drinking water should be monitored because of their potential hazard for human health as an environmental tumor promoter. We describe here a new clean-up tool with immunoaffinity column (IAC) for determination of trace amounts of MCs (from pg to microg/litre) in tap water. The water samples were concentrated with IAC clean-up and MCs levels were determined by HPLC with UV detection or enzyme-linked immunosorbent assay (ELISA). In the combination with HPLC analysis, mean recovery of microcystin-LR (MCLR),-RR and-YR spiked to tap water were 91.8%, 77.3% and 86.4%, respectively, in the range 2.5-100 microg/litre. The chromatogram of MCs-spiked tap water sample cleaned up with IAC showed effective elimination of the impurities compared to that with octadecyl silanized cartridge, which had been cleaned up with a conventional method. Also, in the combination with highly sensitive ELISA, mean recovery of MCLR spiked to tap water was 80% in the range 0.1-1000 ng/litre. The combined methods developed here can detect pg to microg/litre of MCs in tap water. The overall results indicated that IAC will be suitable as a clean-up tool for trace amounts of MCs in tap water.

  17. Fast Gradient Elution Reversed-Phase HPLC with Diode-Array Detection as a High Throughput Screening Method for Drugs of Abuse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peter W. Carr; K.M. Fuller; D.R. Stoll

    A new approach has been developed by modifying a conventional gradient elution liquid chromatograph for the high throughput screening of biological samples to detect the presence of regulated intoxicants. The goal of this work was to improve the speed of a gradient elution screening method over current approaches by optimizing the operational parameters of both the column and the instrument without compromising the reproducibility of the retention times, which are the basis for the identification. Most importantly, the novel instrument configuration substantially reduces the time needed to re-equilibrate the column between gradient runs, thereby reducing the total time for eachmore » analysis. The total analysis time for each gradient elution run is only 2.8 minutes, including 0.3 minutes for column reequilibration between analyses. Retention times standard calibration solutes are reproducible to better than 0.002 minutes in consecutive runs. A corrected retention index was adopted to account for day-to-day and column-to-column variations in retention time. The discriminating power and mean list length were calculated for a library of 47 intoxicants and compared with previous work from other laboratories to evaluate fast gradient elution HPLC as a screening tool.« less

  18. Application of microscopy technique and high performance liquid chromatography for quality assessment of Polygonum multiflorum Thunb. (Heshouwu)

    PubMed Central

    Liang, Li; Zhao, Zhongzhen; Kang, Tingguo

    2014-01-01

    Background: The technique of microscopy has been applied for identification of Chinese materia medica (CMM) since decades. However, very few scientific publications report the combination of conventional microscopy and high performance liquid chromatography (HPLC) techniques for further application to quality assessment of CMM. Objective: The objective of this study is to analyze the quality of the dried root tuber of Polygonum multiflorum Thunb. (Heshouwu) and to establish the relationships between 2,3,5,4’-tetrahydroxystilbene-2-O-β-glucoside, combined anthraquinone (CAQ) and quantity of clusters of calcium oxalate. Materials and Methods: In this study, microscopy and HPLC techniques were applied to assess the quality of P. multiflorum Thunb., and SPSS software was used to establish the relationship between microscopic characteristics and chemical components. Results: The results showed close and direct correlations between the quantity of clusters of calcium oxalate in P. multiflorum Thunb. and the contents of 2,3,5,4’-tetrahydroxystilbene-2-O-β-glucoside and CAQ. From these results, it can be deduced that Polygoni Multiflori Radix with a higher quantity of clusters of calcium oxalate should be of better quality. Conclusion: The established method can be helpful for evaluating the quality of CMM based upon the identification and quantitation of chemical and ergastic substance of cells. PMID:25422540

  19. Microwave-assisted extraction of herbacetin diglucoside from flax (Linum usitatissimum L.) seed cakes and its quantification using an RP-HPLC-UV system.

    PubMed

    Fliniaux, Ophélie; Corbin, Cyrielle; Ramsay, Aina; Renouard, Sullivan; Beejmohun, Vickram; Doussot, Joël; Falguières, Annie; Ferroud, Clotilde; Lamblin, Frédéric; Lainé, Eric; Roscher, Albrecht; Grand, Eric; Mesnard, François; Hano, Christophe

    2014-03-10

    Flax (Linum usitatissimum L.) seeds are widely used for oil extraction and the cold-pressed flaxseed (or linseed) cakes obtained during this process constitute a valuable by-product. The flavonol herbacetin diglucoside (HDG) has been previously reported as a constituent of the flaxseed lignan macromolecule linked through ester bonds to the linker molecule hydroxymethylglutaric acid. In this context, the development and validation of a new approach using microwave-assisted extraction (MAE) of HDG from flaxseed cakes followed by quantification with a reverse-phase HPLC system with UV detection was purposed. The experimental parameters affecting the HDG extraction yield, such as microwave power, extraction time and sodium hydroxide concentration, from the lignan macromolecule were optimized. A maximum HDG concentration of 5.76 mg/g DW in flaxseed cakes was measured following an irradiation time of 6 min, for a microwave power of 150 W using a direct extraction in 0.1 M NaOH in 70% (v/v) aqueous methanol. The optimized method was proven to be rapid and reliable in terms of precision, repeatability, stability and accuracy for the extraction of HDG. Comparison with a conventional extraction method demonstrated that MAE is more effective and less time-consuming.

  20. A receptor binding assay for paralytic shellfish poisoning toxins: recent advances and applications.

    PubMed

    Powell, C L; Doucette, G J

    1999-01-01

    We recently described a high throughput receptor binding assay for paralytic shellfish poisoning (PSP) toxins, the use of the assay for detecting toxic activity in shellfish and algal extracts, and the validation of 11-[3H]-tetrodotoxin as an alternative radioligand to the [3H]-saxitoxin conventionally employed in the assay. Here, we report a dramatic increase in assay efficiency through application of microplate scintillation technology, resulting in an assay turn around time of 4 h. Efforts are now focused on demonstrating the range of applications for which this receptor assay can provide data comparable to the more time consuming, technically demanding HPLC analysis of PSP toxins, currently the method of choice for researchers. To date, we have compared the results of both methods for a variety of sample types, including different genera of PSP toxin producing dinoflagellates (e.g. Alexandrium lusitanicum, r2 = 0.9834, n = 12), size-fractioned field samples of Alexandrium spp. (20-64 microm; r2 = 0.9997, n = 10) as well as its associated zooplankton grazer community (200-500 microm: r2 = 0.6169, n = 10; >500 microm: r2 = 0.5063, n = 10), and contaminated human fluids (r2 = 0.9661, n = 7) from a PSP outbreak. Receptor-based STX equivalent values for all but the zooplankton samples were highly correlated and exhibited close quantitative agreement with those produced by HPLC. While the PSP receptor binding assay does not provide information on toxin composition obtainable by HPLC, it does represent a robust and reliable means of rapidly assessing PSP-like toxicity in laboratory and field samples. Moreover, this assay should be effective as a screening tool for use by public health officials in responding to suspected cases of PSP intoxication.

  1. Implementation of AICAR analysis by GC-C-IRMS for anti-doping purposes.

    PubMed

    Buisson, C; Frelat, C; Mongongu, C; Martinat, N; Audran, M

    2017-11-01

    AICAR (5-aminoimidazole-4-carboxamide-1-β-D-ribofuranoside), is a naturally occurring substance which is part to the World Anti-Doping Agency (WADA) Prohibited List. It is claimed to improve physical performance when administered as a supplement. As for other endogenous compounds such as steroids, the gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) analysis remains an efficient tool to differentiate endogenous substances from exogenous ones. A protocol was described in the literature for the analysis of AICAR by GC-C-IRMS. The aim of the present study was to implement this protocol in our laboratory and to propose solutions to avoid the difficulties encountered. The first point discussed in this study is the derivatization step. Due to the structure of the AICAR molecule, conventional derivatization for GC-C-IRMS such as acetylation could not be applied and silylation was preferred. The improvement of the derivatives stability was achieved thanks to several derivatization conditions tested. This adjustment led to a reproducible derivatization pattern with the 3-TMS form as major derivative product. The second point discussed in this study is the diminution of extracts' background noise. Indeed, the implementation of the published protocol was not easy due to high performance liquid chromatography (HPLC) problems encountered when concentrated urine was injected into our system. Also, too many interferences in the endogenous reference compound fractions were observed. The addition of both a wash step before the HPLC purification and a HPLC purification step for the endogenous reference compound (ERC) fraction allowed us to increase the robustness of the method. This study presents the modified protocol compared to the original protocol as well as the evaluation of the whole method performances. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  2. Rapid and green analytical method for the determination of quinoline alkaloids from Cinchona succirubra based on Microwave-Integrated Extraction and Leaching (MIEL) prior to high performance liquid chromatography.

    PubMed

    Fabiano-Tixier, Anne-Sylvie; Elomri, Abdelhakim; Blanckaert, Axelle; Seguin, Elisabeth; Petitcolas, Emmanuel; Chemat, Farid

    2011-01-01

    Quinas contains several compounds, such as quinoline alkaloids, principally quinine, quinidine, cinchonine and cichonidine. Identified from barks of Cinchona, quinine is still commonly used to treat human malaria. Microwave-Integrated Extraction and Leaching (MIEL) is proposed for the extraction of quinoline alkaloids from bark of Cinchona succirubra. The process is performed in four steps, which ensures complete, rapid and accurate extraction of the samples. Optimal conditions for extraction were obtained using a response surface methodology reached from a central composite design. The MIEL extraction has been compared with a conventional technique soxhlet extraction. The extracts of quinoline alkaloids from C. succirubra obtained by these two different methods were compared by HPLC. The extracts obtained by MIEL in 32 min were quantitatively (yield) and qualitatively (quinine, quinidine, cinchonine, cinchonidine) similar to those obtained by conventional Soxhlet extraction in 3 hours. MIEL is a green technology that serves as a good alternative for the extraction of Cinchona alkaloids.

  3. Rapid and Green Analytical Method for the Determination of Quinoline Alkaloids from Cinchona succirubra Based on Microwave-Integrated Extraction and Leaching (MIEL) Prior to High Performance Liquid Chromatography

    PubMed Central

    Fabiano-Tixier, Anne-Sylvie; Elomri, Abdelhakim; Blanckaert, Axelle; Seguin, Elisabeth; Petitcolas, Emmanuel; Chemat, Farid

    2011-01-01

    Quinas contains several compounds, such as quinoline alkaloids, principally quinine, quinidine, cinchonine and cichonidine. Identified from barks of Cinchona, quinine is still commonly used to treat human malaria. Microwave-Integrated Extraction and Leaching (MIEL) is proposed for the extraction of quinoline alkaloids from bark of Cinchona succirubra. The process is performed in four steps, which ensures complete, rapid and accurate extraction of the samples. Optimal conditions for extraction were obtained using a response surface methodology reached from a central composite design. The MIEL extraction has been compared with a conventional technique soxhlet extraction. The extracts of quinoline alkaloids from C. succirubra obtained by these two different methods were compared by HPLC. The extracts obtained by MIEL in 32 min were quantitatively (yield) and qualitatively (quinine, quinidine, cinchonine, cinchonidine) similar to those obtained by conventional Soxhlet extraction in 3 hours. MIEL is a green technology that serves as a good alternative for the extraction of Cinchona alkaloids. PMID:22174637

  4. Determination of mutagenic amines in water and food samples by high pressure liquid chromatography with amperometric detection using a multiwall carbon nanotubes-glassy carbon electrode.

    PubMed

    Bueno, Ana María; Marín, Miguel Ángel; Contento, Ana María; Ríos, Ángel

    2016-02-01

    A chromatographic method, using amperometric detection, for the sensitive determination of six representative mutagenic amines was developed. A glassy carbon electrode (GCE), modified with multiwall carbon nanotubes (GCE-CNTs), was prepared and its response compared to a conventional glassy carbon electrode. The chromatographic method (HPLC-GCE-CNTs) allowed the separation and the determination of heterocyclic aromatic amines (HAAs) classified as mutagenic amines by the International Agency for Research of Cancer. The new electrode was systematically studied in terms of stability, sensitivity, and reproducibility. Statistical analysis of the obtained data demonstrated that the modified electrode provided better sensitivity than the conventional unmodified ones. Detection limits were in the 3.0 and 7.5 ng/mL range, whereas quantification limits ranged between 9.5 and 25.0 ng/mL were obtained. The applicability of the method was demonstrated by the determination of the amines in several types of samples (water and food samples). Recoveries indicate very good agreement between amounts added and those found for all HAAs (recoveries in the 92% and 105% range). Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Determination of very low levels of 5-(hydroxymethyl)-2-furaldehyde (HMF) in natural honey: comparison between the HPLC technique and the spectrophotometric white method.

    PubMed

    Truzzi, Cristina; Annibaldi, Anna; Illuminati, Silvia; Finale, Carolina; Rossetti, Monica; Scarponi, Giuseppe

    2012-07-01

    In this work we compared 2 official methods for the determination of HMF in honey, the spectrophotometric White method and the HPLC method (International Honey Commission) for the determination of HMF in unifloral honey and honeydew samples with a very low HMF content (<4 mg/kg), which is the most critical determination in terms of accuracy and precision of methods. In honey solutions, the limits of quantification for HPLC and White methods are 0.83 mg/L and 0.67 mg/L, respectively, and the linearity range is confirmed up to 20 mg/L for the HPLC method and up to 5 mg/L for the White method. In honeys with HMF >5 mg/kg, the molar extinction coefficient is 15369, lower than the literature value of 16830, and should be used for HMF determination. For samples with HMF content in the range 1-4 mg/kg the accuracy of the 2 methods is comparable both for unifloral and honeydew samples, whereas as regards precision, the HPLC method gives better results (3.5% compared with 6.4% for the White method). So, in general, the HPLC method seems to be more appropriate for the determination of HMF in honey in the range 1-4 mg/kg thanks to its greater precision, but for samples with a HMF content of less than 1 mg/kg the analyses are inaccurate for both methods. This work can help governmental and private laboratories that perform food analyses to choose the best method for the determination of HMF at very low levels in unifloral honey and honeydew samples. © 2012 Institute of Food Technologists®

  6. A simple analytical procedure to replace HPLC for monitoring treatment concentrations of chloramine-T on fish culture facilities

    USGS Publications Warehouse

    Dawson, Verdel K.; Meinertz, Jeffery R.; Schmidt, Larry J.; Gingerich, William H.

    2003-01-01

    Concentrations of chloramine-T must be monitored during experimental treatments of fish when studying the effectiveness of the drug for controlling bacterial gill disease. A surrogate analytical method for analysis of chloramine-T to replace the existing high-performance liquid chromatography (HPLC) method is described. A surrogate method was needed because the existing HPLC method is expensive, requires a specialist to use, and is not generally available at fish hatcheries. Criteria for selection of a replacement method included ease of use, analysis time, cost, safety, sensitivity, accuracy, and precision. The most promising approach was to use the determination of chlorine concentrations as an indicator of chloramine-T. Of the currently available methods for analysis of chlorine, the DPD (N,N-diethyl-p-phenylenediamine) colorimetric method best fit the established criteria. The surrogate method was evaluated under a variety of water quality conditions. Regression analysis of all DPD colorimetric analyses with the HPLC values produced a linear model (Y=0.9602 X+0.1259) with an r2 value of 0.9960. The average accuracy (percent recovery) of the DPD method relative to the HPLC method for the combined set of water quality data was 101.5%. The surrogate method was also evaluated with chloramine-T solutions that contained various concentrations of fish feed or selected densities of rainbow trout. When samples were analyzed within 2 h, the results of the surrogate method were consistent with those of the HPLC method. When samples with high concentrations of organic material were allowed to age more than 2 h before being analyzed, the DPD method seemed to be susceptible to interference, possibly from the development of other chloramine compounds. However, even after aging samples 6 h, the accuracy of the surrogate DPD method relative to the HPLC method was within the range of 80–120%. Based on the data comparing the two methods, the U.S. Food and Drug Administration has concluded that the DPD colorimetric method is appropriate to use to measure chloramine-T in water during pivotal efficacy trials designed to support the approval of chloramine-T for use in fish culture.

  7. Comparison of the BioRad Variant and Primus Ultra2 high-pressure liquid chromatography (HPLC) instruments for the detection of variant hemoglobins.

    PubMed

    Gosselin, R C; Carlin, A C; Dwyre, D M

    2011-04-01

    Hemoglobin variants are a result of genetic changes resulting in abnormal or dys-synchronous hemoglobin chain production (thalassemia) or the generation of hemoglobin chain variants such as hemoglobin S. Automated high-pressure liquid chromatography (HPLC) systems have become the method of choice for the evaluation of patients suspected with hemoglobinopathies. In this study, we evaluated the performance of two HPLC methods used in the detection of common hemoglobin variants: Variant and Ultra2. There were 377 samples tested, 26% (99/377) with HbS, 8.5% (32/377) with HbC, 20.7% (78/377) with other hemoglobin variant or thalassemia, and 2.9% with increased hemoglobin A(1) c. The interpretations of each chromatograph were compared. There were no differences noted for hemoglobins A(0), S, or C. There were significant differences between HPLC methods for hemoglobins F, A(2), and A(1) c. However, there was good concordance between normal and abnormal interpretations (97.9% and 96.2%, respectively). Both Variant and Ultra2 HPLC methods were able to detect most common hemoglobin variants. There was better discrimination for fast hemoglobins, between hemoglobins E and A(2), and between hemoglobins S and F using the Ultra2 HPLC method. © 2010 Blackwell Publishing Ltd.

  8. Online identification of chlorogenic acids, sesquiterpene lactones, and flavonoids in the Brazilian arnica Lychnophora ericoides Mart. (Asteraceae) leaves by HPLC-DAD-MS and HPLC-DAD-MS/MS and a validated HPLC-DAD method for their simultaneous analysis.

    PubMed

    Gobbo-Neto, Leonardo; Lopes, Norberto P

    2008-02-27

    Lychnophora ericoides Mart. (Asteraceae, Vernonieae) is a plant, endemic to Brazil, with occurrence restricted to the "cerrado" biome. Traditional medicine employs alcoholic and aqueous-alcoholic preparations of leaves from this species for the treatment of wounds, inflammation, and pain. Furthermore, leaves of L. ericoides are also widely used as flavorings for the Brazilian traditional spirit "cachaça". A method has been developed for the extraction and HPLC-DAD analysis of the secondary metabolites of L. ericoides leaves. This analytical method was validated with 11 secondary metabolites chosen to represent the different classes and polarities of secondary metabolites occurring in L. ericoides leaves, and good responses were obtained for each validation parameter analyzed. The same HPLC analytical method was also employed for online secondary metabolite identification by HPLC-DAD-MS and HPLC-DAD-MS/MS, leading to the identification of di- C-glucosylflavones, coumaroylglucosylflavonols, flavone, flavanones, flavonols, chalcones, goyazensolide, and eremantholide-type sesquiterpene lactones and positional isomeric series of chlorogenic acids possessing caffeic and/or ferulic moieties. Among the 52 chromatographic peaks observed, 36 were fully identified and 8 were attributed to compounds belonging to series of caffeoylferuloylquinic and diferuloylquinic acids that could not be individualized from each other.

  9. Improved method for HPLC analysis of polyamines, agmatine and aromatic monoamines in plant tissue

    NASA Technical Reports Server (NTRS)

    Slocum, R. D.; Flores, H. E.; Galston, A. W.; Weinstein, L. H.

    1989-01-01

    The high performance liquid chromatographic (HPLC) method of Flores and Galston (1982 Plant Physiol 69: 701) for the separation and quantitation of benzoylated polyamines in plant tissues has been widely adopted by other workers. However, due to previously unrecognized problems associated with the derivatization of agmatine, this important intermediate in plant polyamine metabolism cannot be quantitated using this method. Also, two polyamines, putrescine and diaminopropane, also are not well resolved using this method. A simple modification of the original HPLC procedure greatly improves the separation and quantitation of these amines, and further allows the simulation analysis of phenethylamine and tyramine, which are major monoamine constituents of tobacco and other plant tissues. We have used this modified HPLC method to characterize amine titers in suspension cultured carrot (Daucas carota L.) cells and tobacco (Nicotiana tabacum L.) leaf tissues.

  10. A high-performance liquid chromatography method for the serotonin release assay is equivalent to the radioactive method.

    PubMed

    Sono-Koree, N K; Crist, R A; Frank, E L; Rodgers, G M; Smock, K J

    2016-02-01

    The serotonin release assay (SRA) is considered the gold standard laboratory test for heparin-induced thrombocytopenia (HIT). The historic SRA method uses platelets loaded with radiolabeled serotonin to evaluate platelet activation by HIT immune complexes. However, a nonradioactive method is desirable. We report the performance characteristics of a high-performance liquid chromatography (HPLC) SRA method. We validated the performance characteristics of an HPLC-SRA method, including correlation with a reference laboratory using the radioactive method. Serotonin released from reagent platelets was quantified by HPLC using fluorescent detection. Results were expressed as % release and classified as positive, negative, or indeterminate based on previously published cutoffs. Serum samples from 250 subjects with suspected HIT were tested in the HPLC-SRA and with the radioactive method. Concordant classifications were observed in 230 samples (92%). Sera from 41 healthy individuals tested negative. Between-run imprecision studies showed standard deviation of <6 (% release) for positive, weak positive, and negative serum pools. Stability studies demonstrated stability after two freeze-thaw cycles or up to a week of refrigeration. The HPLC-SRA has robust performance characteristics, equivalent to the historic radioactive method, but avoids the complexities of working with radioactivity. © 2015 John Wiley & Sons Ltd.

  11. A simple method for HPLC retention time prediction: linear calibration using two reference substances.

    PubMed

    Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng

    2017-01-01

    Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.

  12. HPLC and UPLC methods for the determination of zearalenone in noodles, cereal snacks and infant formula.

    PubMed

    Ok, Hyun Ee; Choi, Sung-Wook; Kim, Meehye; Chun, Hyang Sook

    2014-11-15

    High-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) were compared to validate a method for determination of zearalenone (ZON) in noodles, cereal snacks, and infant formulas. The limits of detection and quantification in HPLC and UPLC were found to be 4.0 and 13.0 μg kg(-1) and 2.5 and 8.3 μg kg(-1), respectively. The average recoveries of ZON by HPLC and UPLC ranged from 79.1% to 105.3% and from 85.1% to 114.5%, respectively. The measurement uncertainties of the two methods for ZON determination were within the maximum standard uncertainty. The two methods showed that the levels of ZON in 163 naturally contaminated samples ranged from 4.3 to 8.3 μg kg(-1) by HPLC and 3.1 to 17.6 μg kg(-1) by UPLC. These findings indicate that either method is suitable for the determination of ZON in noodles, cereal snacks, and infant formulas, but UPLC gives faster results with better sensitivity. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Speciation of inorganic selenium and selenoamino acids by an HPLC-UV-HG-AFS system.

    PubMed

    Ipolyi, I; Corns, W; Stockwell, P; Fodor, P

    2001-01-01

    For the on-line speciation of selenocystine (SeCys), selenomethionine (SeMet), selenoethionine (SeEt), selenite (Se(IV)) and selenate (Se(VI)), a high-performance liquid chromatography-UV irradiation-hydride generation-atomic fluorescence spectro- metric method is described. Separation was carried out on a conventional reversed-phase C18 column modified with didodecyl- dimethylammonium bromide with gradient elution applying two concentrations of ammonium acetate as the mobile phase. UV irradiation and hydride generation parameters were optimized. The obtained detection limits for SeCys, SeMet, SeEt, Se(IV) and Se(VI) were 0.31, 0.43, 0.7, 0.44 and 0.32 ng ml(-1), respectively, using a 100-microl loop. The method was tested with spiked mineral water and two volunteers' urine samples.

  14. Speciation of inorganic selenium and selenoamino acids by an HPLC-UV-HG-AFS system

    PubMed Central

    Ipolyi, I.; Corns, W.; Stockwell, P.; Fodor, P.

    2001-01-01

    For the on-line speciation of selenocystine (SeCys), selenomethionine (SeMet), selenoethionine (SeEt), selenite (Se(IV)) and selenate (Se(VI)), a high-performance liquid chromatography-UV irradiation-hydride generation-atomic fluorescence spectro- metric method is described. Separation was carried out on a conventional reversed-phase C18 column modified with didodecyl- dimethylammonium bromide with gradient elution applying two concentrations of ammonium acetate as the mobile phase. UV irradiation and hydride generation parameters were optimized. The obtained detection limits for SeCys, SeMet, SeEt, Se(IV) and Se(VI) were 0.31, 0.43, 0.7, 0.44 and 0.32 ng ml−1, respectively, using a 100-wl loop. The method was tested with spiked mineral water and two volunteers' urine samples. PMID:18924707

  15. Rapid screening of illicit additives in weight loss dietary supplements with desorption corona beam ionisation (DCBI) mass spectrometry.

    PubMed

    Wang, H; Wu, Y; Zhao, Y; Sun, W; Ding, L; Guo, B; Chen, B

    2012-08-01

    Desorption corona beam ionisation (DCBI), the relatively novel ambient mass spectrometry (MS) technique, was utilised to screen for illicit additives in weight-loss food. The five usually abused chemicals - fenfluramine, N-di-desmethyl sibutramine, N-mono-desmethyl sibutramine, sibutramine and phenolphthalein - were detected with the proposed DCBI-MS method. Fast single-sample and high-throughput analysis was demonstrated. Semi-quantification was accomplished based on peak areas in the ion chromatograms. Four illicit additives were identified and semi-quantified in commercial samples. As there was no tedious sample pre-treatment compared with conventional HPLC methods, high-throughput analysis was achieved with DCBI. The results proved that DCBI-MS is a powerful tool for the rapid screening of illicit additives in weight-loss dietary supplements.

  16. Study of phenformin metabolism in rat liver microsomes by HPLC, CE and on-line HPLC-electrospray ionization mass spectrometry.

    PubMed

    Llambias, E B; Luo, J

    1996-01-01

    Methods for the analysis of phenformin and its metabolite by high-performance liquid chromatography (HPLC), capillary electrophoresis (CE) and high-performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESIMS) are developed. The effects of pH, buffer concentration and proportion of organic modifier on the retention of the compounds in HPLC have been studied. The optimum condition was used for the separation and identification of phenformin and its metabolite in microsomal metabolism by HPLC-ESIMS. A simple CE method is also described for the separation of these compounds. Optimum incubation conditions and cofactor requirements for the formation of 4-hydroxyphenformin by microsomal preparations of rat liver were determined. A linear response in the formation of product was found with increasing concentrations of protein and up to 15 min incubation. High concentrations of phenformin inhibited its metabolite formation, and K(m) was 4 microM.

  17. Fingerprint of Hedyotis diffusa Willd. by HPLC-MS.

    PubMed

    Yang, Ting; Yang, Yi-Hua; Yang, Ju-Yun; Chen, Ben-Mei; Duan, Ju-Ping; Yu, Shu-Yi; Ouyang, Hong-Tao; Cheng, Jun-Ping; Chen, Yu-Xiang

    2008-01-01

    A HPLC-MS fingerprint method has been developed based on the consistent chromatographic features of the major chemical constituents among 10 batches of Hedyotis diffusa Willd. Chromatographic separation was conducted on a Hypersil-Keystone Hypurity C(18) column using methanol:water:acetic acid as the mobile phase. Major compounds, including oleanolic acid, ursolic acid and ferulic acid, were analysed by HPLC-MS. Their analysis was ascertained by comparison with data derived from the standard compounds. The HPLC-MS fingerprint was successfully applied to analyse and differentiate samples from different geographical origins, or processing methods. H. diffusa was well distinguished from Hedyotis chrysotricha by HPLC-MS. Therefore the establishment of fingerprint of H. diffusa is critical in assessing and controlling its overall quality.

  18. Suitability of DPPH spiking for antioxidant screening in natural products: the example of galloyl derivatives from red maple bark extract.

    PubMed

    Geoffroy, Thibaud R; Meda, Naamwin R; Stevanovic, Tatjana

    2017-09-01

    To investigate the antioxidant potential in natural products, radical scavenging tests (ABTS, DPPH, ORAC, etc.) are usually considered as the first approach. In addition to the standard colorimetric assays, methods using separation techniques (on-line and pre-column assays) have been developed in the past decades. Based on the peak area (PA) reductions of compounds monitored by HPLC, the pre-column spiking method allows rapid characterisation of natural matrices avoiding laborious isolation steps. However, available information about the significance of the results produced remains scarce. Here, we report, for the first time, a discussion of the potential of the pre-column DPPH spiking method to pinpoint antioxidant compounds using red maple bark extract (RMBE). First, DPPH spiking was conventionally applied to the galloyl compounds in the extract showing the inadequacy of assessing results by PA reductions. The method was then applied to pure galloyl derivatives, evaluating their molar amount reacted (MAR) for more significance. The comparison with the standard DPPH-HPLC/AE method directly monitoring DPPH • inhibition highlighted the inability to retrieve the respective antioxidant efficiencies (AE) of each compound by using DPPH spiking. Despite its limitations, the DPPH spiking method brought to light an autoxidation phenomenon and a matrix/mixture effect investigated through tertiary mixtures of galloyl compounds. Although restricted to the compounds from one natural matrix, this study questions the validity of the spiking method as usually performed and could serve as a basis for further investigations (explorations of other natural products, kinetics considerations). Graphical abstract Investigation of the pre-column DPPH spiking method through the case of galloyl derivatives.

  19. Liquid microjunction surface sampling coupled with high-pressure liquid chromatography-electrospray ionization-mass spectrometry for analysis of drugs and metabolites in whole-body thin tissue sections.

    PubMed

    Kertesz, Vilmos; Van Berkel, Gary J

    2010-07-15

    In this work, a commercially available autosampler was adapted to perform direct liquid microjunction (LMJ) surface sampling followed by a high-pressure liquid chromatography (HPLC) separation of the extract components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the utility of coupling a separation with this direct liquid extraction based surface sampling approach, four different organs (brain, lung, kidney, and liver) from whole-body thin tissue sections of propranolol dosed and control mice were examined. The parent drug was observed in the chromatograms of the surface sampling extracts from all the organs of the dosed mouse examined. In addition, two isomeric phase II metabolites of propranolol (an aliphatic and an aromatic hydroxypropranolol glucuronide) were observed in the chromatograms of the extracts from lung, kidney, and liver. Confirming the presence of one or the other or both of these glucuronides in the extract from the various organs was not possible without the separation. These drug and metabolite data obtained using the LMJ surface sampling/HPLC-MS method and the results achieved by analyzing similar samples by conventional extraction of the tissues and subsequent HPLC-MS analysis were consistent. The ability to directly and efficiently sample from thin tissue sections via a liquid extraction and then perform a subsequent liquid phase separation increases the utility of this liquid extraction surface sampling approach.

  20. Design and Prototype of an Automated Column-Switching HPLC System for Radiometabolite Analysis.

    PubMed

    Vasdev, Neil; Collier, Thomas Lee

    2016-08-17

    Column-switching high performance liquid chromatography (HPLC) is extensively used for the critical analysis of radiolabeled ligands and their metabolites in plasma. However, the lack of streamlined apparatus and consequently varying protocols remain as a challenge among positron emission tomography laboratories. We report here the prototype apparatus and implementation of a fully automated and simplified column-switching procedure to allow for the easy and automated determination of radioligands and their metabolites in up to 5 mL of plasma. The system has been used with conventional UV and coincidence radiation detectors, as well as with a single quadrupole mass spectrometer.

  1. Rapid, cost-effective and accurate quantification of Yucca schidigera Roezl. steroidal saponins using HPLC-ELSD method.

    PubMed

    Tenon, Mathieu; Feuillère, Nicolas; Roller, Marc; Birtić, Simona

    2017-04-15

    Yucca GRAS-labelled saponins have been and are increasingly used in food/feed, pharmaceutical or cosmetic industries. Existing techniques presently used for Yucca steroidal saponin quantification remain either inaccurate and misleading or accurate but time consuming and cost prohibitive. The method reported here addresses all of the above challenges. HPLC/ELSD technique is an accurate and reliable method that yields results of appropriate repeatability and reproducibility. This method does not over- or under-estimate levels of steroidal saponins. HPLC/ELSD method does not require each and every pure standard of saponins, to quantify the group of steroidal saponins. The method is a time- and cost-effective technique that is suitable for routine industrial analyses. HPLC/ELSD methods yield a saponin fingerprints specific to the plant species. As the method is capable of distinguishing saponin profiles from taxonomically distant species, it can unravel plant adulteration issues. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  2. Detection of malondialdehyde in processed meat products without interference from the ingredients.

    PubMed

    Jung, Samooel; Nam, Ki Chang; Jo, Cheorun

    2016-10-15

    Our aim was to develop a method for accurate quantification of malondialdehyde (MDA) in meat products. MDA content of uncured ground pork (Control); ground pork cured with sodium nitrite (Nitrite); and ground pork cured with sodium nitrite, sodium chloride, sodium pyrophosphate, maltodextrin, and a sausage seasoning (Mix) was measured by the 2-thiobarbituric acid (TBA) assay with MDA extraction by trichloroacetic acid (method A) and two high-performance liquid chromatography (HPLC) methods: i) HPLC separation of the MDA-dinitrophenyl hydrazine adduct (method B) and ii) HPLC separation of MDA (method C) after MDA extraction with acetonitrile. Methods A and B could not quantify MDA accurately in groups Nitrite and Mix. Nevertheless, MDA in groups Control, Nitrite, and Mix was accurately quantified by method C with good recovery. Therefore, direct MDA quantification by HPLC after MDA extraction with acetonitrile (method C) is useful for accurate measurement of MDA content in processed meat products. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Dissolution testing of isoniazid, rifampicin, pyrazinamide and ethambutol tablets using near-infrared spectroscopy (NIRS) and multivariate calibration.

    PubMed

    de Oliveira Neves, Ana Carolina; Soares, Gustavo Mesquita; de Morais, Stéphanie Cavalcante; da Costa, Fernanda Saadna Lopes; Porto, Dayanne Lopes; de Lima, Kássio Michell Gomes

    2012-01-05

    This work utilized the near-infrared spectroscopy (NIRS) and multivariate calibration to measure the percentage drug dissolution of four active pharmaceutical ingredients (APIs) (isoniazid, rifampicin, pyrazinamide and ethambutol) in finished pharmaceutical products produced in the Federal University of Rio Grande do Norte (Brazil). The conventional analytical method employed in quality control tests of the dissolution by the pharmaceutical industry is high-performance liquid chromatography (HPLC). The NIRS is a reliable method that offers important advantages for the large-scale production of tablets and for non-destructive analysis. NIR spectra of 38 samples (in triplicate) were measured using a Bomen FT-NIR 160 MB in the range 1100-2500nm. Each spectrum was the average of 50 scans obtained in the diffuse reflectance mode. The dissolution test, which was initially carried out in 900mL of 0.1N hydrochloric acid at 37±0.5°C, was used to determine the percentage a drug that dissolved from each tablet measured at the same time interval (45min) at pH 6.8. The measurement of the four API was performed by HPLC (Shimadzu, Japan) in the gradiente mode. The influence of various spectral pretreatments (Savitzky-Golay smoothing, Multiplicative Scatter Correction (MSC), and Savitzky-Golay derivatives) and multivariate analysis using the partial least squares (PLS) regression algorithm was calculated by the Unscrambler 9.8 (Camo) software. The correlation coefficient (R(2)) for the HPLC determination versus predicted values (NIRS) ranged from 0.88 to 0.98. The root-mean-square error of prediction (RMSEP) obtained from PLS models were 9.99%, 8.63%, 8.57% and 9.97% for isoniazid, rifampicin, ethambutol and pyrazinamide, respectively, indicating that the NIR method is an effective and non-destructive tool for measurement of drug dissolution from tablets. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  4. Development and validation of chromatographic methods (HPLC and GC) for the determination of the active components (benzocaine, tyrothricin and menthol) of a pharmaceutical preparation.

    PubMed

    Ortiz-Boyer, F; Tena, M T; Luque de Castro, M D; Valcárcel, M

    1995-10-01

    Methods are reported for the determination of tyrothricin and benzocaine by HPLC and menthol by GC in the analysis of throat lozenges (tablets) containing all three compounds. After optimization of the variables involved in both HPLC and GC the methods have been characterized and validated according to the guidelines of the Spanish Pharmacopoeia, and applied to both the monitoring of the manufacturing process and the quality control of the final product.

  5. Use of HPLC/UPLC-spectrophotometry for detection of formazan in in vitro Reconstructed human Tissue (RhT)-based test methods employing the MTT-reduction assay to expand their applicability to strongly coloured test chemicals.

    PubMed

    Alépée, N; Barroso, J; De Smedt, A; De Wever, B; Hibatallah, J; Klaric, M; Mewes, K R; Millet, M; Pfannenbecker, U; Tailhardat, M; Templier, M; McNamee, P

    2015-06-01

    A number of in vitro test methods using Reconstructed human Tissues (RhT) are regulatory accepted for evaluation of skin corrosion/irritation. In such methods, test chemical corrosion/irritation potential is determined by measuring tissue viability using the photometric MTT-reduction assay. A known limitation of this assay is possible interference of strongly coloured test chemicals with measurement of formazan by absorbance (OD). To address this, Cosmetics Europe evaluated use of HPLC/UPLC-spectrophotometry as an alternative formazan measurement system. Using the approach recommended by the FDA guidance for validation of bio-analytical methods, three independent laboratories established and qualified their HPLC/UPLC-spectrophotometry systems to reproducibly measure formazan from tissue extracts. Up to 26 chemicals were then tested in RhT test systems for eye/skin irritation and skin corrosion. Results support that: (1) HPLC/UPLC-spectrophotometry formazan measurement is highly reproducible; (2) formazan measurement by HPLC/UPLC-spectrophotometry and OD gave almost identical tissue viabilities for test chemicals not exhibiting colour interference nor direct MTT reduction; (3) independent of the test system used, HPLC/UPLC-spectrophotometry can measure formazan for strongly coloured test chemicals when this is not possible by absorbance only. It is therefore recommended that HPLC/UPLC-spectrophotometry to measure formazan be included in the procedures of in vitro RhT-based test methods, irrespective of the test system used and the toxicity endpoint evaluated to extend the applicability of these test methods to strongly coloured chemicals. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. An HPLC method to determine sennoside A and sennoside B in Sennae fructus and Sennae folium.

    PubMed

    Rosenthal, Immanuel; Wolfram, Evelyn; Meier, Beat

    2014-01-01

    The current Ph. Eur. monographs for senna pods, senna leaf and senna leaf dry extract standardised describe a photometric assay based on the Bornträger reaction to determine hydroxyanthracene glycosides, calculated as sennoside B. The method is timeconsuming, unspecific for sennosides and the precision is not adequate for a modern assay. The photometric method shall therefore be replaced by a modern HPLC method. About 70 % of the total anthrachinone content in herbal drugs of senna species is due to sennoside A and sennoside B. These substances are therefore suitable for the standardisation of Senna products. The Japanese Pharmacopoeia (JP) already describes an HPLC method to determine sennoside A and sennoside B in the monograph for senna leaf. It uses ion-pair chromatography with tetraheptylammoniumbromide. The procedure described in the monograph has a runtime of 70 min. The adapted and validated method described here uses solid-phase extraction (SPE) which allows a selective sample preparation by using an anion exchange phase. A conventional RP C18 column Tosh TSKgel ODS-80TS (4.6 mm × 150 mm), 5 μm, was used as stationary phase and acetonitrile for chromatography R, water R, phosphoric acid R (200:800:1 V/V/V) as mobile phase. The flow rate was 1.2 mL/min, the column temperature 40 °C, the detection wavelength 380 nm, and the injection volume 20 μL. The runtime is 10 min, the chromatogram shows 2 peaks due to sennoside A/B and 2 additional smaller compounds. One of them is rhein-8-O-glucoside. The procedure has been successfully validated according to ICH guidelines. We analysed 6 batches of Senna. The pods (Senna angustifolia) showed a total content of sennoside A and B of 1.74-2.76 % m/m and the content of senna leaves was clearly lower with 1.07-1.19 % m/m, respectively. The suggested method is considered to be suitable to determine sennoside A and sennoside B in senna leaves and senna pods. The consideration is based on the performed validation and on the results for the analysed samples. A short run time and better resolution are clear advantages of the suggested method, compared to other methods.

  7. Simultaneous determination of five coumarins in Angelicae dahuricae Radix by HPLC/UV and LC-ESI-MS/MS.

    PubMed

    Park, Ah Yeon; Park, So-Young; Lee, Jaehyun; Jung, Mihye; Kim, Jinwoong; Kang, Sam Sik; Youm, Jeong-Rok; Han, Sang Beom

    2009-10-01

    Rapid, simple and reliable HPLC/UV and LC-ESI-MS/MS methods for the simultaneous determination of five active coumarins of Angelicae dahuricae Radix, byakangelicol (1), oxypeucedanin (2), imperatorin (3), phellopterin (4) and isoimperatorin (5) were developed and validated. The separation condition for HPLC/UV was optimized using a Develosil RPAQUEOUS C(30) column using 70% acetonitrile in water as the mobile phase. This HPLC/UV method was successful for providing the baseline separation of the five coumarins with no interfering peaks detected in the 70% ethanol extract of Angelicae dahuricae Radix. The specific determination of the five coumarins was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source (LC-ESI-MS/MS). Multiple reaction monitoring (MRM) in the positive mode was used to enhance the selectivity of detection. The LC-ESI-MS/MS methods were successfully applied for the determination of the five major coumarins in Angelicae dahuricae Radix. These HPLC/UV and LC-ESI-MS/MS methods were validated in terms of recovery, linearity, accuracy and precision (intra- and inter-day validation). Taken together, the shorter analysis time involved makes these HPLC/UV and LC-ESI-MS/MS methods valuable for the commercial quality control of Angelicae dahuricae Radix extracts and its pharmaceutical preparations. Copyright (c) 2009 John Wiley & Sons, Ltd.

  8. Comparison of high-pressure liquid chromatography (HPLC) and Griess reagent-spectroscopic methods for the measurement of nitrate in serum from healthy individuals in the Nordic countries.

    PubMed

    Larsen, Tine Lise; Nilsen, Valentina; Andersen, Dag Olav; Francis, George; Rustad, Pål; Mansoor, Mohammad Azam

    2008-12-01

    Bioavailability of NO can be estimated by measuring the concentration of nitrate (NO(3)) in serum. However, the methods used for the measurement NO(3) in plasma or serum show a great degree of variation. Therefore, we compared two analytical methods for the measurement of NO(3) in serum. The concentration of NO(3) in 600 serum samples collected from healthy individuals was determined by the HPLC and by the Griess reagent-spectroscopic method. The concentration of NO(3) in the samples was 29.4+/-16.1 micromol/L and 26.2+/-14.0 micromol/L (mean+/-SD) measured by HPLC and Griess reagent-spectroscopic method respectively (p<0.0001). We detected a significant correlation between the two methods (R=0.81, p<0.0001). A significant correlation between the two methods may suggest that either method can be used for the measurement of NO(3) in serum, however the Griess reagent-spectroscopic method measures lower concentrations of NO(3) than the HPLC method.

  9. Carbon nanotubes and graphene modified screen-printed carbon electrodes as sensitive sensors for the determination of phytochelatins in plants using liquid chromatography with amperometric detection.

    PubMed

    Dago, Àngela; Navarro, Javier; Ariño, Cristina; Díaz-Cruz, José Manuel; Esteban, Miquel

    2015-08-28

    Nanomaterials are of great interest for the development of electrochemical sensors. Multi-walled carbon nanotubes and graphene were used to modify the working electrode surface of different screen-printed carbon electrodes (SPCE) with the aim of improving the sensitivity of the SPCE and comparing it with the conventional glassy carbon electrode. To assay the usability of these sensors, a HPLC methodology with amperometric detection was developed to analyze several phytochelatins in plants of Hordeum vulgare and Glycine max treated with Hg(II) or Cd(II) giving detection limits in the low μmolL(-1) range. Phytochelatins are low molecular weight peptides with the general structure γ-(Glu-Cys)n-Gly (n=2-5) which are synthesized in plants in the presence of heavy metal ions. These compounds can chelate heavy metal ions by the formation of complexes which, are transported to the vacuoles, where the toxicity is not threatening. For this reason phytochelatins are essential in the detoxification of heavy metal ions in plants. The developed HPLC method uses a mobile phase of 1% of formic acid in water with KNO3 or NaCl (pH=2.00) and 1% of formic acid in acetonitrile. Electrochemical detection at different carbon-based electrodes was used. Among the sensors tested, the conventional glassy carbon electrode offers the best sensitivity although modification improves the sensitivity of the SPCE. Glutathione and several isoforms of phytochelatin two were found in plant extracts of both studied species. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Comparison of spectrofluorometric and HPLC methods for the characterization of fecal porphyrins in river otters.

    PubMed

    Taylor, C; Duffy, L K; Plumley, F G; Bowyer, R T

    2000-09-01

    A spectrofluorometric method (B. Grandchamp et al., 1980, Biochem. Biophys. Acta 629, 577-586) developed for the determination of amounts of uroporphyrin I (Uro I), coproporphyrin III (Copro III), and protoporphyrin IX (Proto IX) in skin fibroblasts was compared with a high-performance liquid chromatography (HPLC) method for the analysis of porphyrins in fecal samples of river otters (Lutra canadensis). Heptacarboxylate porphyrin I and coproporphyrin I, two porphyrins determined to be critical in defining the porphyrin profile in fecal samples of river otters with the HPLC method, contributed substantially to the calculation of the concentrations of Uro I and Copro III, respectively, in standard solutions of porphyrins with the spectrofluorometric method. Fluorescent components of the fecal matrix complicated the determination of the concentrations of Uro I, Copro III, and Proto IX with the spectrofluorometric method and resulted in erroneous values for the concentrations of these porphyrins compared with values determined with the HPLC method. These results indicate that the complexity of the sample, particularly with regard to the potential presence of interfering fluorescent compounds, as well as porphyrins additional to Uro I, Copro III, and Proto IX, should be considered prior to the application of the spectrofluorometric method. An alternative HPLC method developed for the rapid characterization of porphyrin profiles in fecal samples of river otters is described. Copyright 2000 Academic Press.

  11. Screening natural antioxidants in peanut shell using DPPH-HPLC-DAD-TOF/MS methods.

    PubMed

    Qiu, Jiying; Chen, Leilei; Zhu, Qingjun; Wang, Daijie; Wang, Wenliang; Sun, Xin; Liu, Xiaoyong; Du, Fangling

    2012-12-15

    Peanut shell, a byproduct in oil production, is rich in natural antioxidants. Here, a rapid and efficient method using DPPH-HPLC-DAD-TOF/MS was used for the first time to screen antioxidants in peanut shell. The method is based on the hypothesis that upon reaction with 1, 1-diphenyl-2-picrylhydrazyl (DPPH), the peak areas of compounds with potential antioxidant activities in the HPLC chromatogram will be significantly reduced or disappeared, and the identity confirmation could be achieved by HPLC-DAD-TOF/MS technique. With this method, three compounds possessing potential antioxidant activities were found abundantly in the methanolic extract of peanut shell. They were identified as 5,7-dihydroxychromone, eriodictyol, and luteolin. The contents of these compounds were 0.59, 0.92, and 2.36 mg/g, respectively, and luteolin possessed the strongest radical scavenging capacity. DPPH-HPLC-DAD-TOF/MS assay facilitated rapid identification and determination of natural antioxidants in peanut shell, which may be helpful for value-added utilization of peanut processing byproducts. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Repeatability Assessment by ISO 11843-7 in Quantitative HPLC for Herbal Medicines.

    PubMed

    Chen, Liangmian; Kotani, Akira; Hakamata, Hideki; Tsutsumi, Risa; Hayashi, Yuzuru; Wang, Zhimin; Kusu, Fumiyo

    2015-01-01

    We have proposed an assessment methods to estimate the measurement relative standard deviation (RSD) of chromatographic peaks in quantitative HPLC for herbal medicines by the methodology of ISO 11843 Part 7 (ISO 11843-7:2012), which provides detection limits stochastically. In quantitative HPLC with UV detection (HPLC-UV) of Scutellaria Radix for the determination of baicalin, the measurement RSD of baicalin by ISO 11843-7:2012 stochastically was within a 95% confidence interval of the statistically obtained RSD by repetitive measurements (n = 6). Thus, our findings show that it is applicable for estimating of the repeatability of HPLC-UV for determining baicalin without repeated measurements. In addition, the allowable limit of the "System repeatability" in "Liquid Chromatography" regulated in a pharmacopoeia can be obtained by the present assessment method. Moreover, the present assessment method was also successfully applied to estimate the measurement RSDs of quantitative three-channel liquid chromatography with electrochemical detection (LC-3ECD) of Chrysanthemi Flos for determining caffeoylquinic acids and flavonoids. By the present repeatability assessment method, reliable measurement RSD was obtained stochastically, and the experimental time was remarkably reduced.

  13. Direct measurement of the glucuronide conjugate of 1-hydroxypyrene in human urine by using liquid chromatography with tandem mass spectrometry.

    PubMed

    Kakimoto, Kensaku; Toriba, Akira; Ohno, Takanori; Ueno, Mariko; Kameda, Takayuki; Tang, Ning; Hayakawa, Kazuichi

    2008-05-15

    To evaluate human exposure to polycyclic aromatic hydrocarbons (PAHs), we developed a rapid, simple and sensitive method for determining 1-hydroxypyrene-glucuronide (1-OHP-G) in human urine. To improve precision, a deuterated glucuronide was used as an internal standard. The method requires only 1 mL of urine. The urine was treated with a mixed-mode anion-exchange and reversed-phase solid-phase extraction cartridge (Oasis MAX). The analytes were analyzed with a C(18) reversed-phase column with a gradient elution, followed by tandem mass spectrometry with electrospray ionization in negative ion mode. The detection limit of 1-OHP-G (corresponding to a signal-to-noise ratio of 3) was 0.13 fmol/injection. Urinary concentrations of 1-OHP-G determined by this method were strongly correlated (r(2)=0.961) with concentrations of 1-hydroxypyrene by conventional HPLC with fluorescence detection.

  14. Quantitative evaluation of refolding conditions for a disulfide-bond-containing protein using a concise 18O-labeling technique

    PubMed Central

    Uchimura, Hiromasa; Kim, Yusam; Mizuguchi, Takaaki; Kiso, Yoshiaki; Saito, Kazuki

    2011-01-01

    A concise method was developed for quantifying native disulfide-bond formation in proteins using isotopically labeled internal standards, which were easily prepared with proteolytic 18O-labeling. As the method has much higher throughput to estimate the amounts of fragments possessing native disulfide arrangements by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) than the conventional high performance liquid chromatography (HPLC) analyses, it allows many different experimental conditions to be assessed in a short time. The method was applied to refolding experiments of a recombinant neuregulin 1-β1 EGF-like motif (NRG1-β1), and the optimum conditions for preparing native NRG1-β1 were obtained by quantitative comparisons. Protein disulfide isomerase (PDI) was most effective at the reduced/oxidized glutathione ratio of 2:1 for refolding the denatured sample NRG1-β1 with the native disulfide bonds. PMID:21500299

  15. Examining the extraction of artemisinin from artemisia annua using ultrasound

    NASA Astrophysics Data System (ADS)

    Briars, Rhianna; Paniwnyk, Larysa

    2012-05-01

    Artemisinin suppresses the life-cycle of the plasmodium parasite which causes malaria. It is found naturally occurring within the trichome glands of the Artemisia annua plant. Traditional methods for extracting artemisinin are time-consuming and have high environmental impact due to the temperatures and organic solvents which must be employed. Ultrasound decreases these through acoustic streaming and micro-jets. But to fully utilise this technology parameters, such as frequency, temperature and the properties of leaf and solvent, must be explored. As with the extraction process there is also no set analysis method for identification of artemisinin. Therefore several methods of analysing these extracts are employed. Initial results indicate that sonication is able to enhance levels of artemisinin extracted when compared to the conventional/traditional extraction process. In addition Thin Layer Chromatography (TLC) and High Performance Liquid Chromatography (HPLC) have been shown to have a high level of reproducible calibration.

  16. A simple analytical procedure to replace HPLC for monitoring treatment concentrations of chloramine-T on fish culture facilities

    USGS Publications Warehouse

    Dawson, V.K.; Meinertz, J.R.; Schmidt, L.J.; Gingerich, W.H.

    2003-01-01

    Concentrations of chloramine-T must be monitored during experimental treatments of fish when studying the effectiveness of the drug for controlling bacterial gill disease. A surrogate analytical method for analysis of chloramine-T to replace the existing high-performance liquid chromatography (HPLC) method is described. A surrogate method was needed because the existing HPLC method is expensive, requires a specialist to use, and is not generally available at fish hatcheries. Criteria for selection of a replacement method included ease of use, analysis time, cost, safety, sensitivity, accuracy, and precision. The most promising approach was to use the determination of chlorine concentrations as an indicator of chloramine-T. Of the currently available methods for analysis of chlorine, the DPD (N,N-diethyl-p-phenylenediamine) colorimetric method best fit the established criteria. The surrogate method was evaluated under a variety of water quality conditions. Regression analysis of all DPD colorimetric analyses with the HPLC values produced a linear model (Y=0.9602 X+0.1259) with an r2 value of 0.9960. The average accuracy (percent recovery) of the DPD method relative to the HPLC method for the combined set of water quality data was 101.5%. The surrogate method was also evaluated with chloramine-T solutions that contained various concentrations of fish feed or selected densities of rainbow trout. When samples were analyzed within 2 h, the results of the surrogate method were consistent with those of the HPLC method. When samples with high concentrations of organic material were allowed to age more than 2 h before being analyzed, the DPD method seemed to be susceptible to interference, possibly from the development of other chloramine compounds. However, even after aging samples 6 h, the accuracy of the surrogate DPD method relative to the HPLC method was within the range of 80-120%. Based on the data comparing the two methods, the U.S. Food and Drug Administration has concluded that the DPD colorimetric method is appropriate to use to measure chloramine-T in water during pivotal efficacy trials designed to support the approval of chloramine-T for use in fish culture. ?? 2003 Elsevier Science B.V. All rights reserved.

  17. Comparison of a specific HPLC determination of toxic aconite alkaloids in processed Radix aconiti with a titration method of total alkaloids.

    PubMed

    Csupor, Dezso; Borcsa, Botond; Heydel, Barbara; Hohmann, Judit; Zupkó, István; Ma, Yan; Widowitz, Ute; Bauer, Rudolf

    2011-10-01

    In traditional Chinese medicine, Aconitum (Ranunculaceae) roots are only applied after processing. Nevertheless, several cases of poisoning by improperly processed aconite roots have been reported. The aim of this study was to develop a reliable analytical method to assess the amount of toxic aconite alkaloids in commercial aconite roots, and to compare this method with the commonly used total alkaloid content determination by titration. The content of mesaconitine, aconitine, and hypaconitine in 16 commercial samples of processed aconite roots was determined by an HPLC method and the total alkaloid content by indirect titration. Five samples were selected for in vivo toxicological investigation. In most of the commercial samples, toxic alkaloids were not detectable, or only traces were found. In four samples, we could detect >0.04% toxic aconite alkaloids, the highest with a content of 0.16%. The results of HPLC analysis were compared with the results obtained by titration, and no correlation was found between the two methods. The in vivo results reassured the validity of the HPLC determination. Samples with mesaconitine, aconitine, and hypaconitine content below the HPLC detection limit still contained up to 0.2% alkaloids determined by titration. Since titration of alkaloids gives no information selectively on the aconitine-type alkaloid content and toxicity of aconite roots this method is not appropriate for safety assessment. The HPLC method developed by us provides a quick and reliable assessment of toxicity and should be considered as a purity test in pharmacopoeia monographs.

  18. Analysis of munitions constituents in IMX formulations by HPLC and HPLC-MS.

    PubMed

    Russell, A L; Seiter, J M; Coleman, J G; Winstead, B; Bednar, A J

    2014-10-01

    The use of Insensitive Munitions eXplosives (IMX) is increasing as the Army seeks to replace certain conventional munitions constituents, such as 2,4,6-trinitrotolene (TNT), for improved safety. The IMX formulations are more stable and therefore less prone to accidental detonation while designed to match the performance of legacy materials. Two formulations, IMX 101 and 104 are being investigated as a replacement for TNT in artillery rounds and composition B Army mortars, respectively. The chemical formulations of IMX-101 and 104 are comprised of four constituents;2,4-dinitroanisole (DNAN), 3-nitro-1,2,4-triazol-5-one (NTO), 1-nitroguanidine (NQ), and Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) which are mixed in various ratios to achieve the desired performance. The current work details the analysis of the IMX constituents by single column HPLC-UV-ESI-MS. Detection limits determined are in agreement with similar HPLC analysis of compounds, ranging from 7 to 9μg/L. Gradient mobile phases are used to allow separation of the 4 target compounds in more complex mixture of other concomitant compounds. Mass spectra are used to confirm analyte identity with chromatographic retention time. Published by Elsevier B.V.

  19. Chromatographic and Spectrophotometric Analysis of Phenolic Compounds from Fruits of Libidibia ferrea Martius

    PubMed Central

    Ferreira, Magda R. A.; Fernandes, Mônica T. M.; da Silva, Wliana A. V.; Bezerra, Isabelle C. F.; de Souza, Tatiane P.; Pimentel, Maria F.; Soares, Luiz A. L.

    2016-01-01

    Background: Libidibia ferrea (Mart. ex Tul.) L.P. Queiroz (Fabaceae) is a tree which is native to Brazil, widely known as “Jucá,” where its herbal derivatives are used in folk medicine with several therapeutic properties. The constituents, which have already been described in the fruit, are mainly hydrolysable tannins (gallic acid [GA] and ellagic acid [EA]). Objective: The aim of this study was to investigate the phenolic variability in the fruit of L. ferrea by ultraviolet/visible (UV/VIS) and chromatographic methods (high-performance liquid chromatography [HPLC]/high-performance thin layer chromatography [HPTLC]). Materials and Methods: Several samples were collected from different regions of Brazil and the qualitative (fingerprints by HPTLC and HPLC) and quantitative analysis (UV/VIS and HPLC) of polyphenols were performed. Results: The HPTLC and HPLC profiles allowed separation and identification of both major analytical markers: EA and GA. The chemical profiles were similar in a number of spots or peaks for the samples, but some differences could be observed in the intensity or area of the analytical markers for HPTLC or HPLC, respectively. Regarding the quantitative analysis, the polyphenolic content by UV/VIS ranged from 13.99 to 37.86 g% expressed as GA or from 10.75 to 29.09 g% expressed as EA. The contents of EA and GA by liquid chromatography-reversed phase (LC-RP) method ranged from 0.57 to 2.68 g% and from 0.54 to 3.23 g%, respectively. Conclusion: The chemical profiles obtained by HPTLC or HPLC, as well as the quantitative analysis by spectrophotometry or LC-RP method, were suitable for discrimination of each herbal sample and can be used as tools for the comparative analysis of the fruits from L. ferrea. SUMMARY The polyphenols of fruits of Libidibia ferrea can be quantified by UV/VIS and HPLCThe HPLC method was able to detect the gallic and ellagic acids in several samples of fruits of Libidibia ferreaThe phenolic profiles of fruits from Libidibia ferrea by HPTLC and HPLC were reproductible. Abbreviations used: HPTLC: high performance thin layer chromatography, HPLC: high performance liquid chromatography, UV-Vis: spectrophotometry PMID:27279721

  20. Stir bar sorptive extraction approaches with a home-made portable electric stirrer for the analysis of polycyclic aromatic hydrocarbon compounds in environmental water.

    PubMed

    Mao, Xiangju; Hu, Bin; He, Man; Fan, Wenying

    2012-10-19

    In this study, novel off/on-site stir bar sorptive extraction (SBSE) approaches with a home-made portable electric stirrer have been developed for the analysis of polycyclic aromatic hydrocarbon compounds (PAHs). In these approaches, a miniature battery-operated electric stirrer was employed to provide agitation of sample solutions instead of the commonly used large size magnetic stirrer powered by alternating current in conventional SBSE process, which could extend the SBSE technique from the conventional off-site analysis to the on-site sampling. The applicability of the designed off/on-site SBSE sampling approaches was evaluated by polydimethylsiloxane (PDMS) coating SBSE-high performance liquid chromatography-fluorescence detection (HPLC-FLD) analysis of six target PAHs in environmental water. The home-made portable electric stirrer is simple, easy-to-operate, user friendly, low cost, easy-to-be-commercialized, and can be processed in direct immersion SBSE, headspace sorptive extraction (HSSE) and continuous flow (CF)-SBSE modes. Since the stir bar was fixed onto the portable device by magnetic force, it is very convenient to install, remove and replace the stir bar, and the coating friction loss which occurred frequently in conventional SBSE process could be avoided. The parameters affecting the extraction of six target PAHs by the home-made portable SBSE sampling device with different sampling modes were studied. Under the optimum extraction conditions, good linearity was obtained by all of three SBSE extraction modes with correlation coefficient (R) higher than 0.9971. The limits of detection (LODs, S/N=3) were 0.05-3.41 ng L(-1) for direct immersion SBSE, 0.03-2.23 ng L(-1) for HSSE and 0.09-3.75 ng L(-1) for CF-SBSE, respectively. The proposed portable PDMS-SBSE-HPLC-FLD method was applied for the analysis of six target PAHs in East Lake water, and the analytical results obtained by on-site SBSE sampling were in good agreement with that obtained by off-site SBSE sampling. The accuracy of the developed method was evaluated by recovery test and the recoveries for the spiked sample were found to be in the range of 87.1-122.8% for off-site CF-SBSE, 88.8-114.3% for on-site sampling, and 87.7-123.6% for off-site SBSE, respectively. The developed method is one of the most sensitive methods for PAHs determination and the home-designed SBSE system is feasible for the field sampling. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Three-year comparative study of polyphenol contents and antioxidant capacities in fruits of tomato (Lycopersicon esculentum Mill.) cultivars grown under organic and conventional conditions.

    PubMed

    Anton, Dea; Matt, Darja; Pedastsaar, Priit; Bender, Ingrid; Kazimierczak, Renata; Roasto, Mati; Kaart, Tanel; Luik, Anne; Püssa, Tõnu

    2014-06-04

    In the present study, four tomato cultivars were grown under organic and conventional conditions in separate unheated greenhouses in three consecutive years. The objective was to assess the influence of the cultivation system on the content of individual polyphenols, total phenolics, and antioxidant capacity of tomatoes. The fruits were analyzed for total phenolic content by the Folin-Ciocalteau method and antioxidant capacity by the DPPH free radical scavenging assay. Individual phenolic compounds were analyzed using HPLC-DAD-MS/MS. Among 30 identified and quantified polyphenols, significantly higher contents of apigenin acetylhexoside, caffeic acid hexoside I, and phloretin dihexoside were found in all organic samples. The content of polyphenols was more dependent on year and cultivar than on cultivation conditions. Generally, the cultivation system had minor impact on polyphenols content, and only a few compounds were influenced by the mode of cultivation in all tested cultivars during all three years.

  2. Optimization of microwave-assisted extraction of flavonoids from young barley leaves

    NASA Astrophysics Data System (ADS)

    Gao, Tian; Zhang, Min; Fang, Zhongxiang; Zhong, Qifeng

    2017-01-01

    A central composite design combined with response surface methodology was utilized to optimise microwave-assisted extraction of flavonoids from young barley leaves. The results showed that using water as solvent, the optimum conditions of microwave-assisted extraction were extracted twice at 1.27 W g-1 microwave power and liquid-solid ratio 34.02 ml g-1 for 11.12 min. The maximum extraction yield of flavonoids (rutin equivalents) was 80.78±0.52%. Compared with conventional extraction method, the microwave-assisted extraction was more efficient as the extraction time was only 6.18% of conventional extraction, but the extraction yield of flavonoids was increased by 5.47%. The main flavonoid components from the young barley leaf extract were probably 33.36% of isoorientin-7-O-glueoside and 54.17% of isovitexin-7-O-glucoside, based on the HPLC-MS analysis. The barley leaf extract exhibited strong reducing power as well as the DPPH radical scavenging capacity.

  3. Cold column trapping-cloud point extraction coupled to high performance liquid chromatography for preconcentration and determination of curcumin in human urine.

    PubMed

    Rahimi, Marzieh; Hashemi, Payman; Nazari, Fariba

    2014-05-15

    A cold column trapping-cloud point extraction (CCT-CPE) method coupled to high performance liquid chromatography (HPLC) was developed for preconcentration and determination of curcumin in human urine. A nonionic surfactant, Triton X-100, was used as the extraction medium. In the proposed method, a low surfactant concentration of 0.4% v/v and a short heating time of only 2min at 70°C were sufficient for quantitative extraction of the analyte. For the separation of the extraction phase, the resulted cloudy solution was passed through a packed trapping column that was cooled to 0 °C. The temperature of the CCT column was then increased to 25°C and the surfactant rich phase was desorbed with 400μL ethanol to be directly injected into HPLC for the analysis. The effects of different variables such as pH, surfactant concentration, cloud point temperature and time were investigated and optimum conditions were established by a central composite design (response surface) method. A limit of detection of 0.066mgL(-1) curcumin and a linear range of 0.22-100mgL(-1) with a determination coefficient of 0.9998 were obtained for the method. The average recovery and relative standard deviation for six replicated analysis were 101.0% and 2.77%, respectively. The CCT-CPE technique was faster than a conventional CPE method requiring a lower concentration of the surfactant and lower temperatures with no need for the centrifugation. The proposed method was successfully applied to the analysis of curcumin in human urine samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Development and optimisation of an HPLC-DAD-ESI-Q-ToF method for the determination of phenolic acids and derivatives.

    PubMed

    Restivo, Annalaura; Degano, Ilaria; Ribechini, Erika; Colombini, Maria Perla

    2014-01-01

    A method for the HPLC-MS/MS analysis of phenols, including phenolic acids and naphtoquinones, using an amide-embedded phase column was developed and compared to the literature methods based on classical C18 stationary phase columns. RP-Amide is a recently developed polar embedded stationary phase, whose wetting properties mean that up to 100% water can be used as an eluent. The increased retention and selectivity for polar compounds and the possibility of working in 100% water conditions make this column particularly interesting for the HPLC analysis of phenolic acids and derivatives. In this study, the chromatographic separation was optimised on an HPLC-DAD, and was used to separate 13 standard phenolic acids and derivatives. The method was validated on an HPLC-ESI-Q-ToF. The acquisition was performed in negative polarity and MS/MS target mode. Ionisation conditions and acquisition parameters for the Q-ToF detector were investigated by working on collision energies and fragmentor potentials. The performance of the method was fully evaluated on standards. Moreover, several raw materials containing phenols were analysed: walnut, gall, wine, malbec grape, French oak, red henna and propolis. Our method allowed us to characterize the phenolic composition in a wide range of matrices and to highlight possible matrix effects.

  5. Determination of CMPO using HPLC -UV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gracy Elias; Gary S. Groenewold; Bruce J. Mincher

    Octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) is an extractant proposed for selective separation of radionuclide metals from used nuclear fuel solutions using solvent extraction. Radiolysis reactions can degrade CMPO and reduce separation performance and hence methods for measuring concentration of CMPO and identifying degradation products are needed. A novel high performance liquid chromatography (HPLC) method employing ultraviolet detection (UV) was developed to detect and quantitate CMPO in dodecane. Some radiolysis products in gamma and alpha irradiated CMPO solutions were identified using HPLC/electrospray ionization-mass spectrometry (ESI-MS). Validation data indicated that the HPLC-UV method for CMPO determination provided good linearity, sensitivity, procedure accuracy and systemmore » precision. CMPO-nitric acid complexes were also identified, that account for the apparent loss of CMPO in acidic environment, independent of irradiation.« less

  6. Evaluation of hemoglobin A1c measurement from filter paper using high-performance liquid chromatography and immunoturbidimetric assay.

    PubMed

    Wu, Yonghua; Yang, Xu; Wang, Haining; Li, Zhenrong; Wang, Tiancheng

    2017-04-01

    Glycated hemoglobin (HbA 1c ) measurement from whole blood (WB) samples is inconvenient for epidemic surveillance and self-monitoring of glycemic level. We evaluated HbA 1c measurement from WB blotted on filter paper (FP), which can be easily transported to central laboratories, with high-performance liquid chromatography (HPLC) and immunoturbidimetric assay (ITA). WB was applied to Whatman filter paper. By using HPLC and WB samples as reference methods, these FP samples were evaluated on HPLC and ITA. Inter- and intra-assay variation, WB vs. FP agreement and sample stability at 20-25 °C and -70 °C were assessed by statistical analysis. Results showed that the coefficient of variation (CV, %) of FP samples for HPLC and ITA were 0.44-1.02% and 1.47-2.72%, respectively (intra-assay); 2.13-3.56% and 3.21-4.82%, respectively (inter-assay). The correlation of WB HPLC with FP analyzed using HPLC and ITA are both significant (p < 0.001). Sample stability showed that FP method up to 5 days at 20-25 °C and 5 weeks at -70 °C is accurate and reproducible. In conclusion, FP samples analyzed by HPLC and ITA can both provide an alternative to WB for HbA 1c measurement, supporting the use of FP method in epidemic surveillance and healthcare units.

  7. Development of high performance liquid chromatography method for miconazole analysis in powder sample

    NASA Astrophysics Data System (ADS)

    Hermawan, D.; Suwandri; Sulaeman, U.; Istiqomah, A.; Aboul-Enein, H. Y.

    2017-02-01

    A simple high performance liquid chromatography (HPLC) method has been developed in this study for the analysis of miconazole, an antifungal drug, in powder sample. The optimized HPLC system using C8 column was achieved using mobile phase composition containing methanol:water (85:15, v/v), a flow rate of 0.8 mL/min, and UV detection at 220 nm. The calibration graph was linear in the range from 10 to 50 mg/L with r 2 of 0.9983. The limit of detection (LOD) and limit of quantitation (LOQ) obtained were 2.24 mg/L and 7.47 mg/L, respectively. The present HPLC method is applicable for the determination of miconazole in the powder sample with a recovery of 101.28 % (RSD = 0.96%, n = 3). The developed HPLC method provides short analysis time, high reproducibility and high sensitivity.

  8. Comparison of HPLC, UV spectrophotometry and potentiometric titration methods for the determination of lumefantrine in pharmaceutical products.

    PubMed

    da Costa César, Isabela; Nogueira, Fernando Henrique Andrade; Pianetti, Gérson Antônio

    2008-09-10

    This paper describes the development and evaluation of a HPLC, UV spectrophotometry and potentiometric titration methods to quantify lumefantrine in raw materials and tablets. HPLC analyses were carried out using a Symmetry C(18) column and a mobile phase composed of methanol and 0.05% trifluoroacetic acid (80:20), with a flow rate of 1.0ml/min and UV detection at 335nm. For the spectrophotometric analyses, methanol was used as solvent and the wavelength of 335nm was selected for the detection. Non-aqueous titration of lumefantrine was carried out using perchloric acid as titrant and glacial acetic acid/acetic anhydride as solvent. The end point was potentiometrically determined. The three evaluated methods showed to be adequate to quantify lumefantrine in raw materials, while HPLC and UV methods presented the most reliable results for the analyses of tablets.

  9. New validated high-performance liquid chromatographic method for simultaneous analysis of ten flavonoid aglycones in plant extracts using a C18 fused-core column and acetonitrile-tetrahydrofuran gradient.

    PubMed

    Olszewska, Monika A

    2012-09-01

    An HPLC method of high resolution has been developed and validated for the simultaneous determination of ten prominent flavonoid aglycones in plant materials using a fused-core C18-silica column (Ascentis® Express, 4.6 mm × 150 mm, 2.7 μm). The separation was accomplished with an acetonitrile-tetrahydrofuran gradient elution at a flow rate of 1 mL/min and temperature of 30°C. UV spectrophotometric detection was employed at 370 nm for flavonols (quercetin [QU], myricetin [MY], isorhamnetin [IS], kaempferol [KA], sexangularetin [SX], and limocitrin [LM]) and 340 nm for flavones (apigenin [AP], acacetin [AC], chrysoeriol [CH], and luteolin [LU]). The high resolution of critical pairs QU/LU (10.50), QU/CH (3.40), AP/CH (2.51), SX/LM (2.30), and IS/KA (2.70) was achieved within 30.3 min. The observed column back pressure was less than 4300 psi, thus acceptable for conventional HPLC equipment. The method was sensitive enough having LODs of 0.115-0.525 ng and good linearity (r > 0.9999) over the test range. The precision values, expressed as RSD values, were <7.5%, and the accuracy was in the range of 95.3-100.2% for all analytes except MY (73.8%). The method was successfully employed for the determination of flavonoids in several medicinal plants, such as Ginkgo biloba, Betula pendula, and a variety of Sorbus species. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Analysis of clonazepam in a tablet dosage form using smallbore HPLC.

    PubMed

    Spell, J C; Stewart, J T

    1998-11-01

    A stability indicating, reversed phase high-performance liquid chromatographic method utilizing a smallbore HPLC column has been developed for the determination of clonazepam in a commercial tablet dosage form. The use of a small bore column results in a substantial solvent savings, as well as a greater mass sensitivity, especially in the identification of degradation peaks in a chromatogram. The method involves ultraviolet detection at 254 nm and utilized a 150 x 3.0 mm i.d. column packed with 3 microm octyldecylsilane particles with a mobile phase of water methanol acetonitrile (40:30:30, v/v/v) at a flow rate of 400 microl min(-1) at ambient temperature, with and without the use of 1,2-dichlorobenzene as the internal standard. The current USP method for the analysis of clonazepam using a 300 x 3.9 mm i.d. conventional octyldecylsilane column was utilized as a comparison to the smallbore method. The retention times for clonazepam and the internal standard on the 3.0 mm i.d. column were 4.0 and 12.5 min, respectively. The intra- and interday RSDs on the 3.0 mm i.d. column were < 0.55% (n =4) using the internal standard, and < 0.19% (n = 4) without the internal standard at the lower limit of the standard curve, 50 microg ml(-1) and had a limit of detection of 24 ng ml(-1). The assay using the 3.0 mm i.d. column was shown to be suitable for measuring clonazepam in a tablet dosage form.

  11. Two-dimensional preparative liquid chromatography system for preparative separation of minor amount components from complicated natural products.

    PubMed

    Qiu, Ying-Kun; Chen, Fang-Fang; Zhang, Ling-Ling; Yan, Xia; Chen, Lin; Fang, Mei-Juan; Wu, Zhen

    2014-04-11

    An on-line comprehensive two-dimensional preparative liquid chromatography system was developed for preparative separation of minor amount components from complicated natural products. Medium-pressure liquid chromatograph (MPLC) was applied as the first dimension and preparative HPLC as the second one, in conjunction with trapping column and makeup pump. The performance of the trapping column was evaluated, in terms of column size, dilution ratio and diameter-height ratio, as well as system pressure from the view of medium pressure liquid chromatograph. Satisfactory trapping efficiency can be achieved using a commercially available 15 mm × 30 mm i.d. ODS pre-column. The instrument operation and the performance of this MPLC×preparative HPLC system were illustrated by gram-scale isolation of crude macro-porous resin enriched water extract of Rheum hotaoense. Automated multi-step preparative separation of 25 compounds, whose structures were identified by MS, (1)H NMR and even by less-sensitive (13)C NMR, could be achieved in a short period of time using this system, exhibiting great advantages in analytical efficiency and sample treatment capacity compared with conventional methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Simultaneous determination of quinolones in fish by liquid chromatography coupled with fluorescence detection: comparison of sub-2 microm particles and conventional C18 columns.

    PubMed

    Zhang, Hong; Chen, Si; Lu, Yanbin; Dai, Zhiyuan

    2010-07-01

    A simple and effective multi-residue analysis method is presented for the extraction and determination of eleven quinolones (pipemidic acid, enoxacin, norfloxacin, ciprofloxacin, lomefloxacin, enrofloxacin, gatifloxacin, difloxacin, oxolinic acid, nalidixic acid and flumequine) in fish tissues. In this study, multi-residue separations on four columns packed with 5 microm or sub-2 microm particles were simultaneously developed for the purpose of comparison. Various gradients were optimized and best resolutions were achieved on each column. A short and sub-2 microm particle-sized HPLC column was chosen for its advantages in analysis time and column performance. Additionally, considering the matrix effect of the complex crude fish tissue, an effective extraction protocol was also established for sample pre-treatment procedure. Good recoveries (71-98%) were obtained from samples fortified with a mix of eleven quinolones at three levels, with satisfactory relative standard deviations and limits of detection. As a result, the sub-2 microm HPLC column and proposed analytical procedures have been evaluated and applied to the analysis of different fish tissues. Detectable residues were observed in 8 of 30 samples, at concentrations ranging from 4.74 to 23.27 microg/kg.

  13. [HPLC fingerprint analysis of flavonoids of phyllanthi fructus from different habitats].

    PubMed

    Wang, Fei; Wang, Shuai; Meng, Xian-sheng; Bao, Yong-rui; Zhu, Ying-huan

    2014-11-01

    To establish the HPLC fingerprint of flavonoids of Phyllanthi Fructus from different habitats. HPLC method was adopted. The flavonoids composition of Phyllanthi Fructus from 10 different habitats was determined on an Agilent C, chromatographic column with 0. 5% formic acid water (A)-acetonitrile (B) as the mobile phase in gradient elution under the wavelength of 254 nm. The HPLC fingerprints of flavonoids composition of Phyllanthi Fructus were established to evaluate the qualitiy of them. The HPLC fingerprints of flavonoids composition of Phyllanthi Fructus from 10 different habitats were established. 18 common peaks were found and the similarities of them were more than 0. 90 except the ones from Guangxi and Guangdong. The method is simple, accurate and repeatable. It can be used for research and quality control of the effective components in Phyllanthi Fructus.

  14. Dodecyl Maltopyranoside Enabled Purification of Active Human GABA Type A Receptors for Deep and Direct Proteomic Sequencing*

    PubMed Central

    Zhang, Xi; Miller, Keith W.

    2015-01-01

    The challenge in high-quality membrane proteomics is all about sample preparation prior to HPLC, and the cell-to-protein step poses a long-standing bottleneck. Traditional protein extraction methods apply ionic or poly-disperse detergents, harsh denaturation, and repeated protein/peptide precipitation/resolubilization afterward, but suffer low yield, low reproducibility, and low sequence coverage. Contrary to attempts to subdue, we resolved this challenge by providing proteins nature-and-activity-promoting conditions throughout preparation. Using 285-kDa hetero-pentameric human GABA type A receptor overexpressed in HEK293 as a model, we describe a n-dodecyl-β-d-maltopyranoside/cholesteryl hemisuccinate (DDM/CHS)-based affinity purification method, that produced active receptors, supported protease activity, and allowed high performance with both in-gel and direct gel-free proteomic analyses—without detergent removal. Unlike conventional belief that detergents must be removed before HPLC MS, the high-purity low-dose nonionic detergent DDM did not interfere with peptides, and obviated removal or desalting. Sonication or dropwise addition of detergent robustly solubilized over 90% of membrane pellets. The purification conditions were comparable to those applied in successful crystallizations of most membrane proteins. These results enabled streamlined proteomics of human synaptic membrane proteins, and more importantly, allowed directly coupling proteomics with crystallography to characterize both static and dynamic structures of membrane proteins in crystallization pipelines. PMID:25473089

  15. Hydrogen sulfide measurement using sulfide dibimane: critical evaluation with electrospray ion trap mass spectrometry

    PubMed Central

    Shen, Xinggui; Chakraborty, Sourav; Dugas, Tammy R; Kevil, Christopher G

    2015-01-01

    Accurate measurement of hydrogen sulfide bioavailability remains a technical challenge due to numerous issues involving sample processing, detection methods used, and actual biochemical products measured. Our group and others have reported that reverse phase HPLC detection of sulfide dibimane (SDB) product from the reaction of H2S/HS− with monobromobimane allows for analytical detection of hydrogen sulfide bioavailability in free and other biochemical forms. However, it remains unclear whether possible interfering contaminants may contribute to HPLC SDB peak readings that may result in inaccurate measurements of bioavailable sulfide. In this study, we critically compared hydrogen sulfide dependent SDB detection using reverse phase HPLC (RP-HPLC) versus quantitative SRM electrospray ionization mass spectrometry (ESI/MS) to obtain greater clarity into the validity of the reverse phase HPLC method for analytical measurement of hydrogen sulfide. Using an LCQ-deca ion-trap mass spectrometer, SDB was identified by ESI/MS positive ion mode, and quantified by selected reaction monitoring (SRM) using hydrocortisone as an internal standard. Collision induced dissociation (CID) parameters were optimized at MS2 level for SDB and hydrocortisone. ESI/MS detection of SDB standard was found to be a log order more sensitive than RP-HPLC with a lower limit of 0.25 nM. Direct comparison of tissue and plasma SDB levels using RP-HPLC and ESI/MS methods revealed comparable sulfide levels in plasma, aorta, heart, lung and brain. Together, these data confirm the use of SDB as valid indicator of H2S bioavailability and highlights differences between analytical detection methods. PMID:24932544

  16. Effect of eluent pH on the HPLC-UV analysis of hyperforin from St. John's Wort (Hypericum perforatum L.).

    PubMed

    Fourneron, Jean-Dominique; Naït-Si, Youssef

    2006-01-01

    The effect of the pH of the mobile phase in HPLC analysis of hyperforin was investigated. Working with an extract of St. John's Wort (Hypericum perforatum L.) that is rich in hyperforin, significant differences were observed in conventional chromatograms depending on whether the mobile phase was acidic or alkaline. Chromatogram changes were paralleled by changes in the UV spectrum of the hyperforin peak. The structural changes in hyperforin occur in the chromatographic column itself, as has been confirmed by UV spectroscopy performed on a sample of purified hyperforin, which showed that the UV spectrum is indeed dependent on the pH of its environment.

  17. Analyses of procyanidins in foods using Diol phase HPLC

    USDA-ARS?s Scientific Manuscript database

    Separation of procyanidins using silica-based HPLC suffered from poor resolution for higher oligomers and low sensitivity due to the fluorescence quenching effects of methylene chloride in the mobile phase. Optimization of a published Diol-phase HPLC method resulted in near baseline separation for p...

  18. Method transfer from high-pressure liquid chromatography to ultra-high-pressure liquid chromatography. I. A thermodynamic perspective.

    PubMed

    Åsberg, Dennis; Leśko, Marek; Samuelsson, Jörgen; Kaczmarski, Krzysztof; Fornstedt, Torgny

    2014-10-03

    This is the first investigation in a series that aims to enhance the scientific knowledge needed for reliable analytical method transfer between HPLC and UHPLC using the quality by design (QbD) framework. Here, we investigated the differences and similarities from a thermodynamic point of view between RP-LC separations conducted with 3.5μm (HPLC) and 1.7μm (UHPLC) C18 particles. Three different model solutes and one pharmaceutical compound were used: the uncharged cycloheptanone, the cationic benzyltriethylammonium chloride, the anionic sodium 2-naphatlene sulfonate and the pharmaceutical compound omeprazole, which was anionic at the studied pH. Adsorption data were determined for the four solutes at varying fractions of organic modifier and in gradient elution in both the HPLC and UHPLC system, respectively. From the adsorption data, the adsorption energy distribution of each compound was calculated and the adsorption isotherm model was estimated. We found that the adsorption energy distribution was similar, with only minor differences in degree of homogeneity, for HPLC and UHPLC stationary phases. The adsorption isotherm model did not change between HPLC and UHPLC, but the parameter values changed considerably especially for the ionic compounds. The dependence of the organic modifier followed the same trend in HPLC as in UHPLC. These results indicates that the adsorption mechanism of a solute is the same on HPLC and UHPLC stationary phases which simplifies design of a single analytical method applicable to both HPLC and UHPLC conditions within the QbD framework. Copyright © 2014. Published by Elsevier B.V.

  19. Simultaneous Determination of First-Line 4-FDC Antituberculosis Drugs by UHPLC-UV and HPLC-UV: A Comparative Study.

    PubMed

    Franco, Pedro H C; Chellini, Paula R; Oliveira, Marcone A L; Pianetti, Gerson A

    2017-07-01

    Tuberculosis is the second most deadly infectious disease, surpassed only by HIV/AIDS, and has resulted in over 1 billion deaths in the last 200 years. The World Health Organization estimates that in 2014, 9.6 million people were infected by this disease and 1.5 million had died. First-choice treatment consists of fixed-dose combination tablets containing rifampicin, isoniazid, pyrazinamide, and ethambutol hydrochloride (4-FDC). There are pharmacopeial protocols available to test 4-FDC, but they are prolonged, two-step methods. One single-step method in the literature performs the simultaneous determination by HPLC, but requires a long acquisition time. In this context, an ultra-HPLC (UHPLC) method was developed based on the HPLC method with the objective of reducing analysis time. A C18 column (1.9 µm particle size) was used with UV-diode-array detection at 238 and 282 nm. The method was found to be selective, linear, exact, precise, and robust. Samples from two batches were analyzed and the results compared with those obtained by the HPLC method, with no statistically significant differences observed (P > 0.05). This UHPLC method reduced the analysis time from 17 to 4 min, with a more than 90% reduction in sample and reagent consumption and a financial economy of almost 50-fold.

  20. Development and validation of polar RP-HPLC method for screening for ectoine high-yield strains in marine bacteria with green chemistry.

    PubMed

    Chen, Jun; Chen, Jianwei; Wang, Sijia; Zhou, Guangmin; Chen, Danqing; Zhang, Huawei; Wang, Hong

    2018-04-02

    A novel, green, rapid, and precise polar RP-HPLC method has been successfully developed and screened for ectoine high-yield strain in marine bacteria. Ectoine is a polar and extremely useful solute which allows microorganisms to survive in extreme environmental salinity. This paper describes a polar-HPLC method employed polar RP-C18 (5 μm, 250 × 4.6 mm) using pure water as the mobile phase and a column temperature of 30 °C, coupled with a flow rate at 1.0 mL/min and detected under a UV detector at wavelength of 210 nm. Our method validation demonstrates excellent linearity (R 2  = 0.9993), accuracy (100.55%), and a limit of detection LOQ and LOD of 0.372 and 0.123 μgmL -1 , respectively. These results clearly indicate that the developed polar RP-HPLC method for the separation and determination of ectoine is superior to earlier protocols.

  1. Development and Validation of an HPLC Method for Karanjin in Pongamia pinnata linn. Leaves.

    PubMed

    Katekhaye, S; Kale, M S; Laddha, K S

    2012-01-01

    A rapid, simple and specific reversed-phase HPLC method has been developed for analysis of karanjin in Pongamia pinnata Linn. leaves. HPLC analysis was performed on a C(18) column using an 85:13.5:1.5 (v/v) mixtures of methanol, water and acetic acid as isocratic mobile phase at a flow rate of 1 ml/min. UV detection was at 300 nm. The method was validated for accuracy, precision, linearity, specificity. Validation revealed the method is specific, accurate, precise, reliable and reproducible. Good linear correlation coefficients (r(2)>0.997) were obtained for calibration plots in the ranges tested. Limit of detection was 4.35 μg and limit of quantification was 16.56 μg. Intra and inter-day RSD of retention times and peak areas was less than 1.24% and recovery was between 95.05 and 101.05%. The established HPLC method is appropriate enabling efficient quantitative analysis of karanjin in Pongamia pinnata leaves.

  2. Development and Validation of an HPLC Method for Karanjin in Pongamia pinnata linn. Leaves

    PubMed Central

    Katekhaye, S; Kale, M. S.; Laddha, K. S.

    2012-01-01

    A rapid, simple and specific reversed-phase HPLC method has been developed for analysis of karanjin in Pongamia pinnata Linn. leaves. HPLC analysis was performed on a C18 column using an 85:13.5:1.5 (v/v) mixtures of methanol, water and acetic acid as isocratic mobile phase at a flow rate of 1 ml/min. UV detection was at 300 nm. The method was validated for accuracy, precision, linearity, specificity. Validation revealed the method is specific, accurate, precise, reliable and reproducible. Good linear correlation coefficients (r2>0.997) were obtained for calibration plots in the ranges tested. Limit of detection was 4.35 μg and limit of quantification was 16.56 μg. Intra and inter-day RSD of retention times and peak areas was less than 1.24% and recovery was between 95.05 and 101.05%. The established HPLC method is appropriate enabling efficient quantitative analysis of karanjin in Pongamia pinnata leaves. PMID:23204626

  3. Comparison of analytical methods for the determination of histamine in reference canned fish samples

    NASA Astrophysics Data System (ADS)

    Jakšić, S.; Baloš, M. Ž.; Mihaljev, Ž.; Prodanov Radulović, J.; Nešić, K.

    2017-09-01

    Two screening methods for histamine in canned fish, an enzymatic test and a competitive direct enzyme-linked immunosorbent assay (CD-ELISA), were compared with the reversed-phase liquid chromatography (RP-HPLC) standard method. For enzymatic and CD-ELISA methods, determination was conducted according to producers’ manuals. For RP-HPLC, histamine was derivatized with dansyl-chloride, followed by RP-HPLC and diode array detection. Results of analysis of canned fish, supplied as reference samples for proficiency testing, showed good agreement when histamine was present at higher concentrations (above 100 mg kg-1). At a lower level (16.95 mg kg-1), the enzymatic test produced some higher results. Generally, analysis of four reference samples according to CD-ELISA and RP-HPLC showed good agreement for histamine determination (r=0.977 in concentration range 16.95-216 mg kg-1) The results show that the applied enzymatic test and CD-ELISA appeared to be suitable screening methods for the determination of histamine in canned fish.

  4. Determination of vitamins D2 and D3 in selected food matrices by online high-performance liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS).

    PubMed

    Nestola, Marco; Thellmann, Andrea

    2015-01-01

    An online normal-phase liquid chromatography-gas chromatography-mass spectrometry (HPLC-GC-MS) method was developed for the determination of vitamins D2 and D3 in selected food matrices. Transfer of the sample from HPLC to GC was realized by large volume on-column injection; detection was performed with a time-of-flight mass spectrometer (TOF-MS). Typical GC problems in the determination of vitamin D such as sample degradation or sensitivity issues, previously reported in the literature, were not observed. Determination of total vitamin D content was done by quantitation of its pyro isomer based on an isotopically labelled internal standard (ISTD). Extracted ion traces of analyte and ISTD showed cross-contribution, but non-linearity of the calibration curve was not determined inside the chosen calibration range by selection of appropriate quantifier ions. Absolute limits of detection (LOD) and quantitation (LOQ) for vitamins D2 and D3 were calculated as approximately 50 and 150 pg, respectively. Repeatability with internal standard correction was below 2 %. Good agreement between quantitative results of an established high-performance liquid chromatography with UV detection (HPLC-UV) method and HPLC-GC-MS was found. Sterol-enriched margarine was subjected to HPLC-GC-MS and HPLC-MS/MS for comparison, because HPLC-UV showed strong matrix interferences. HPLC-GC-MS produced comparable results with less manual sample cleanup. In summary, online hyphenation of HPLC and GC allowed a minimization in manual sample preparation with an increase of sample throughput.

  5. Analysis of sesquiterpene lactones, lignans, and flavonoids in wormwood (Artemisia absinthium L.) using high-performance liquid chromatography (HPLC)-mass spectrometry, reversed phase HPLC, and HPLC-solid phase extraction-nuclear magnetic resonance.

    PubMed

    Aberham, Anita; Cicek, Serhat Sezai; Schneider, Peter; Stuppner, Hermann

    2010-10-27

    Today, the medicinal use of wormwood (Artemisia absinthium) is enjoying a resurgence of popularity. This study presents a specific and validated high-performance liquid chromatography (HPLC)-diode array detection method for the simultaneous determination and quantification of bioactive compounds in wormwood and commercial preparations thereof. Five sesquiterpene lactones, two lignans, and a polymethoxylated flavonoid were baseline separated on RP-18 material, using a solvent gradient consisting of 0.085% (v/v) o-phosphoric acid and acetonitrile. The flow rate was 1.0 mL/min, and chromatograms were recorded at 205 nm. The stability of absinthin was tested exposing samples to light, moisture, and different temperatures. Methanolic and aqueous solutions of absinthin were found to be stable for up to 6 months. This was also the case when the solid compound was kept in the refrigerator at -35 °C. In contrast, the colorless needles, when stored at room temperature, turned yellow. Three degradation compounds (anabsin, anabsinthin, and the new dimer 3'-hydroxyanabsinthin) were identified by HPLC-mass spectrometry and HPLC-solid-phase extraction-nuclear magnetic resonance and quantified by the established HPLC method.

  6. Quantitative determination of ambroxol in tablets by derivative UV spectrophotometric method and HPLC.

    PubMed

    Dinçer, Zafer; Basan, Hasan; Göger, Nilgün Günden

    2003-04-01

    A derivative UV spectrophotometric method for the determination of ambroxol in tablets was developed. Determination of ambroxol in tablets was conducted by using first-order derivative UV spectrophotometric method at 255 nm (n = 5). Standards for the calibration graph ranging from 5.0 to 35.0 microg/ml were prepared from stock solution. The proposed method was accurate with 98.6+/-0.4% recovery value and precise with coefficient of variation (CV) of 1.22. These results were compared with those obtained by reference methods, zero-order UV spectrophotometric method and reversed-phase high-performance liquid chromatography (HPLC) method. A reversed-phase C(18) column with aqueous phosphate (0.01 M)-acetonitrile-glacial acetic acid (59:40:1, v/v/v) (pH 3.12) mobile phase was used and UV detector was set to 252 nm. Calibration solutions used in HPLC were ranging from 5.0 to 20.0 microg/ml. Results obtained by derivative UV spectrophotometric method was comparable to those obtained by reference methods, zero-order UV spectrophotometric method and HPLC, as far as ANOVA test, F(calculated) = 0.762 and F(theoretical) = 3.89, was concerned. Copyright 2003 Elsevier Science B.V.

  7. Determination of tocopherol and tocotrienol content of Greek barley varieties under conventional and organic cultivation techniques using validated reverse phase high-performance liquid chromatography method.

    PubMed

    Tsochatzis, Emmanouil D; Bladenopoulos, Konstantinos; Papageorgiou, Maria

    2012-06-01

    Tocotrienols and tocopherols (tocols) are important phytochemical compounds with antioxidant activity and potential benefits for human health. Among cereals, barley is a good source of tocols. In the present study the effect of two cultivation methods, organic and conventional, on the tocol content in 12 Greek barley varieties was investigated. A validated reverse phase high-performance liquid chromatography method (RP-HPLC) with fluorescence detection (excitation at 292 nm, emission at 335 nm) was applied along with direct solvent extraction with acetonitrile at a 1:30 (w/v) sample/solvent ratio for tocol quantification. The results showed statistically significant differences (P < 0.05) between the two cultivation methods (except for δ-tocopherol) as well as among varieties. In the case of organic cultivation the four homologues of tocotrienol (α-, β + γ- and δ-) increased, by 3.05-37.14% for α-tocotrienol, 15.51-41.09% for (β + γ)-tocotrienol and 30.45-196.61% for δ-tocotrienol, while those of tocopherol (α- and β + γ- but not δ-) decreased, by 5.90-36.34% for α-tocopherol and 2.84-46.49% for (β + γ)-tocopherol. A simple correlation analysis between tocols revealed a good correlation between (β + γ)-tocotrienol and δ-tocotrienol. Although there was a significant decrease in the important α-tocopherol in the varieties studied under organic cultivation, there was an overall increase in tocotrienol content. The cultivation method (organic or conventional) had an important effect on tocotrienol and tocopherol concentrations in barley. An overall increase in total tocol content and a clear increment in the tocotrienol/tocopherol ratio were observed. Copyright © 2012 Society of Chemical Industry.

  8. Selenium speciation analysis of Misgurnus anguillicaudatus selenoprotein by HPLC-ICP-MS and HPLC-ESI-MS/MS

    USDA-ARS?s Scientific Manuscript database

    Analytical methods for selenium (Se) speciation were developed using high performance liquid chromatography (HPLC) coupled to either inductively coupled plasma mass spectrometry (ICP-MS) or electrospray ionization tandem mass spectrometry (ESI-MS/MS). Separations of selenomethionine (Se-Met) and sel...

  9. Competitive Nitration of Benzene-Fluorobenzene and Benzene-Toluene Mixtures: Orientation and Reactivity Studies Using HPLC

    ERIC Educational Resources Information Center

    Blankespoor, Ronald L.; Hogendoorn, Stephanie; Pearson, Andrea

    2007-01-01

    The reactivity and orientation effects of a substituent are analyzed by using HPLC to determine the competitive nitration of the benzene-toluene and benzene-fluorobenzene mixtures. The results have shown that HPLC is an excellent instrumental method to use in analyzing these mixtures.

  10. Conventional sample enrichment strategies combined with high-performance liquid chromatography-solid phase extraction-nuclear magnetic resonance analysis allows analyte identification from a single minuscule Corydalis solida plant tuber.

    PubMed

    Sturm, Sonja; Seger, Christoph; Godejohann, Markus; Spraul, Manfred; Stuppner, Hermann

    2007-09-07

    Identification of putative biomarker molecules within the genus Corydalis (Papaveraceae) was pursued by combining conventional off-line sample enrichment with high-performance liquid chromatography-solid phase extraction-nuclear magnetic resonance (HPLC-SPE-NMR) based structure elucidation. Off-line reversed phase solid phase extraction (SPE) was used to enrich the desired analytes from a methanolic extract (93 mg dry weight) of a miniscule single tuber (233 mg dry weight) of C. solida. An aliquot of the SPE fraction (2.1 mg) was subjected to separation in the HPLC-SPE-NMR hyphenation. Chromatographic peaks bearing the metabolites under investigation were trapped in the SPE device in a single experiment and transferred to a 600 MHz NMR spectrometer equipped with a 30 microl cryofit insert fed into a 3 mm cryoprobe. Recorded homo- and heteronuclear 1D and 2D NMR data allowed the identification of the three analytes under investigation as protopine, allocryptopine, and N-methyl-laudanidinium acetate. The latter is a rare alkaloid, which has been isolated only once before.

  11. Cyanobacteria and Cyanotoxins Occurrence and Removal from Five High-Risk Conventional Treatment Drinking Water Plants.

    PubMed

    Szlag, David C; Sinclair, James L; Southwell, Benjamin; Westrick, Judy A

    2015-06-12

    An environmental protection agency EPA expert workshop prioritized three cyanotoxins, microcystins, anatoxin-a, and cylindrospermopsin (MAC), as being important in freshwaters of the United States. This study evaluated the prevalence of potentially toxin producing cyanobacteria cell numbers relative to the presence and quantity of the MAC toxins in the context of this framework. Total and potential toxin producing cyanobacteria cell counts were conducted on weekly raw and finished water samples from utilities located in five US states. An Enzyme-Linked Immunosorbant Assay (ELISA) was used to screen the raw and finished water samples for microcystins. High-pressure liquid chromatography with a photodiode array detector (HPLC/PDA) verified microcystin concentrations and quantified anatoxin-a and cylindrospermopsin concentrations. Four of the five utilities experienced cyanobacterial blooms in their raw water. Raw water samples from three utilities showed detectable levels of microcystins and a fourth utility had detectable levels of both microcystin and cylindrospermopsin. No utilities had detectable concentrations of anatoxin-a. These conventional plants effectively removed the cyanobacterial cells and all finished water samples showed MAC levels below the detection limit by ELISA and HPLC/PDA.

  12. Characterization of Compounds in Psoralea corylifolia Using High-Performance Liquid Chromatography Diode Array Detection, Time-of-Flight Mass Spectrometry and Quadrupole Ion Trap Mass Spectrometry.

    PubMed

    Tan, Guangguo; Yang, Tiehong; Miao, Huayan; Chen, Hao; Chai, Yifeng; Wu, Hong

    2015-10-01

    High-performance liquid chromatography with diode array detection (HPLC-DAD), time-of-flight mass spectrometry (HPLC-TOFMS) and quadrupole ion trap mass spectrometry (HPLC-QITMS) were used for separation and identification of multi-components in Psoralea corylifolia. Benefiting from combining the accurate mass measurement of HPLC-TOFMS to generate elemental compositions, the complementary multilevel structural information provided by HPLC-QITMS and the characteristic UV spectra obtained from HPLC-DAD, 24 components in P. corylifolia were identified. The five groups of isomers were differentiated based on the fragmentation behaviors in QITMS and UV spectra. It can be concluded that an effective method based on the combination of HPLC-DAD, HPLC-TOFMS and HPLC-QITMS for identification of chemical components in P. corylifolia was established. The results provide essential data for further pharmacological and clinical studies of P. corylifolia and facilitate the rapid quality control of the crude drug. © Crown copyright 2015.

  13. A simple and accurate HPLC method for fecal bile acid profile in healthy and cirrhotic subjects: validation by GC-MS and LC-MS[S

    PubMed Central

    Kakiyama, Genta; Muto, Akina; Takei, Hajime; Nittono, Hiroshi; Murai, Tsuyoshi; Kurosawa, Takao; Hofmann, Alan F.; Pandak, William M.; Bajaj, Jasmohan S.

    2014-01-01

    We have developed a simple and accurate HPLC method for measurement of fecal bile acids using phenacyl derivatives of unconjugated bile acids, and applied it to the measurement of fecal bile acids in cirrhotic patients. The HPLC method has the following steps: 1) lyophilization of the stool sample; 2) reconstitution in buffer and enzymatic deconjugation using cholylglycine hydrolase/sulfatase; 3) incubation with 0.1 N NaOH in 50% isopropanol at 60°C to hydrolyze esterified bile acids; 4) extraction of bile acids from particulate material using 0.1 N NaOH; 5) isolation of deconjugated bile acids by solid phase extraction; 6) formation of phenacyl esters by derivatization using phenacyl bromide; and 7) HPLC separation measuring eluted peaks at 254 nm. The method was validated by showing that results obtained by HPLC agreed with those obtained by LC-MS/MS and GC-MS. We then applied the method to measuring total fecal bile acid (concentration) and bile acid profile in samples from 38 patients with cirrhosis (17 early, 21 advanced) and 10 healthy subjects. Bile acid concentrations were significantly lower in patients with advanced cirrhosis, suggesting impaired bile acid synthesis. PMID:24627129

  14. Current HPLC Methods for Assay of Nano Drug Delivery Systems.

    PubMed

    Tekkeli, Serife Evrim Kepekci; Kiziltas, Mustafa Volkan

    2017-01-01

    In nano drug formulations the mechanism of release is a critical process to recognize controlled and targeted drug delivery systems. In order to gain high bioavailability and specificity from the drug to reach its therapeutic goal, the active substance must be loaded into the nanoparticles efficiently. Therefore, the amount in biological fluids or tissues and the remaining amount in nano carriers are very important parameters to understand the potential of the nano drug delivery systems. For this aim, suitable and validated quantitation methods are required to determine released drug concentrations from nano pharmaceutical formulations. HPLC (High Performance Liquid Chromatography) is one of the most common techniques used for determination of released drug content out of nano drug formulations, in different physical conditions, over different periods of time. Since there are many types of HPLC methods depending on detector and column types, it is a challenge for the researchers to choose a suitable method that is simple, fast and validated HPLC techniques for their nano drug delivery systems. This review's goal is to compare HPLC methods that are currently used in different nano drug delivery systems in order to provide detailed and useful information for researchers. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  15. Assay of fluoxetine hydrochloride by titrimetric and HPLC methods.

    PubMed

    Bueno, F; Bergold, A M; Fröehlich, P E

    2000-01-01

    Two alternative methods were proposed to assay Fluoxetine Hydrochloride: a titrimetric method and another by HPLC using as mobile phase water pH 3.5: acetonitrile (65:35). These methods were applied to the determination of Fluoxetine as such or in formulations (capsules). The titrimetric method is an alternative for pharmacies and small industries. Both methods showed accuracy and precision and are an alternative to the official methods.

  16. Development and Validation of HPLC-DAD and UHPLC-DAD Methods for the Simultaneous Determination of Guanylhydrazone Derivatives Employing a Factorial Design.

    PubMed

    Azevedo de Brito, Wanessa; Gomes Dantas, Monique; Andrade Nogueira, Fernando Henrique; Ferreira da Silva-Júnior, Edeildo; Xavier de Araújo-Júnior, João; Aquino, Thiago Mendonça de; Adélia Nogueira Ribeiro, Êurica; da Silva Solon, Lilian Grace; Soares Aragão, Cícero Flávio; Barreto Gomes, Ana Paula

    2017-08-30

    Guanylhydrazones are molecules with great pharmacological potential in various therapeutic areas, including antitumoral activity. Factorial design is an excellent tool in the optimization of a chromatographic method, because it is possible quickly change factors such as temperature, mobile phase composition, mobile phase pH, column length, among others to establish the optimal conditions of analysis. The aim of the present work was to develop and validate a HPLC and UHPLC methods for the simultaneous determination of guanylhydrazones with anticancer activity employing experimental design. Precise, exact, linear and robust HPLC and UHPLC methods were developed and validated for the simultaneous quantification of the guanylhydrazones LQM10, LQM14, and LQM17. The UHPLC method was more economic, with a four times less solvent consumption, and 20 times less injection volume, what allowed better column performance. Comparing the empirical approach employed in the HPLC method development to the DoE approach employed in the UHPLC method development, we can conclude that the factorial design made the method development faster, more practical and rational. This resulted in methods that can be employed in the analysis, evaluation and quality control of these new synthetic guanylhydrazones.

  17. Isolation and identification of arctiin and arctigenin in leaves of burdock (Arctium lappa L.) by polyamide column chromatography in combination with HPLC-ESI/MS.

    PubMed

    Liu, Shiming; Chen, Kaoshan; Schliemann, Willibald; Strack, Dieter

    2005-01-01

    A simple method involving polyamide column chromatography in combination with HPLC-PAD and HPLC-ESI/MS for isolating and identifying two kinds of lignans, arctiin and arctigenin, in the leaves of burdock (Arctium lappa L.) has been established. After extraction of burdock leaves with 80% methanol, the aqueous phase of crude extracts was partitioned between water and chloroform and the aqueous phase was fractionated on a polyamide glass column. The fraction, eluting with 100% methanol, was concentrated and gave a white precipitate at 4 degrees C from which two main compounds were purified by semi-preparative HPLC. In comparison with the UV and ESI-MS spectra and the HPLC retention time of authentic standards, the compounds were determined to be arctiin and arctigenin. The extraction/separation technique was validated using an internal standard method.

  18. Prenatal diagnosis of hemoglobinopathies: evaluation of techniques for analysing globin-chain synthesis in blood samples obtained by fetoscopy.

    PubMed Central

    Congote, L. F.; Hamilton, E. F.; Chow, J. C.; Perry, T. B.

    1982-01-01

    Three techniques for analysing hemoglobin synthesis in blood samples obtained by fetoscopy were evaluated. Of the fetuses studied, 12 were not at risk of genetic disorders, 10 were at risk of beta-thalassemia, 2 were at risk of sickle cell anemia and 1 was at risk of both diseases. The conventional method of prenatal diagnosis of hemoglobinopathies, involving the separation of globin chains labelled with a radioactive isotope on carboxymethyl cellulose (CMC) columns, was compared with a method involving globin-chain separation by high-pressure liquid chromatography (HPLC) and with direct analysis of labelled hemoglobin tetramers obtained from cell lysates by chromatography on ion-exchange columns. The last method is technically the simplest and can be used for diagnosing beta-thalassemia and sickle cell anemia. However, it gives spuriously high levels of adult hemoglobin in samples containing nonlabelled adult hemoglobin. HPLC is the fastest method for prenatal diagnosis of beta-thalassemia and may prove as reliable as the CMC method. Of the 13 fetuses at risk for hemoglobinopathies, 1 was predicted to be affected, and the diagnosis was confirmed in the abortus. Of 12 predicted to be unaffected, 1 was aborted spontaneously and was unavailable for confirmatory studies, as were 3 of the infants; however, the diagnosis was confirmed in seven cases and is awaiting confirmation when the infant in 6 months old in one case. Couples at risk of bearing a child with a hemoglobinopathy should be referred for genetic counselling before pregnancy or, at the latest, by the 12th week of gestation so that prenatal diagnosis can be attempted by amniocentesis, safer procedure, with restriction endonuclease analysis of the amniotic fluid cells. PMID:7139502

  19. Stability-Indicating TLC-Densitometric and HPLC Methods for the Simultaneous Determination of Piracetam and Vincamine in the Presence of Their Degradation Products.

    PubMed

    Ahmed, Amal B; Abdelrahman, Maha M; Abdelwahab, Nada S; Salama, Fathy M

    2016-11-01

    Newly established TLC-densitometric and RP-HPLC methods were developed and validated for the simultaneous determination of Piracetam (PIR) and Vincamine (VINC) in their pharmaceutical formulation and in the presence of PIR and VINC degradation products, PD and VD, respectively. The proposed TLC-densitometric method is based on the separation and quantitation of the studied components using a developing system that consists of chloroform-methanol-glacial acetic acid-triethylamine (8 + 2 + 0.1 + 0.1, v/v/v/v) on TLC silica gel 60 F254 plates, followed by densitometric scanning at 230 nm. On the other hand, the developed RP-HPLC method is based on the separation of the studied components using an isocratic elution of 0.05 M KH2PO4 (containing 0.1% triethylamine adjusted to pH 3 with orthophosphoric acid)-methanol (95 + 5, v/v) on a C8 column at a flow rate of 1 mL/min with diode-array detection at 230 nm. The developed methods were validated according to International Conference on Harmonization guidelines and demonstrated good accuracy and precision. Moreover, the developed TLC-densitometric and RP-HPLC methods are suitable as stability-indicating assay methods for the simultaneous determination of PD and VD either in bulk powder or pharmaceutical formulation. The results were statistically compared with those obtained by the reported RP-HPLC method using t- and F-tests.

  20. A novel HPLC fluorescence method for the quantification of methylphenidate in human plasma

    PubMed Central

    Zhu, Hao-Jie; Wang, Jun-Sheng; Patrick, Kennerly S.; Donovan, Jennifer L.; DeVane, C. Lindsay; Markowitz, John S.

    2007-01-01

    A number of analytical methods have been established to quantify methylphenidate (MPH). However, to date no HPLC methods are applicable to human pharmacokinetic studies without the use of mass spectrometry (MS) detection. We developed a sensitive and reliable HPLC-fluorescence method for the determination of MPH in human plasma using 4-(4,5-diphenyl-1H-imidazol-2-yl) benzoyl chloride (DIB-Cl) as the derivatizing agent. An established GC-MS method was adopted in this study as a comparator assay. MPH was derivatized DIB-Cl, and separated isocratically on a C18 column using a HPLC system with fluorescence detection (λex: 330 nm, λem: 460 nm). The lower limit of determination was found to be 1 ng/mL. A linear calibration curve was obtained over the concentrations ranging from 1 to 80 ng/mL (r=0.998). The relative standard deviations of intra-day and inter-day variations were ≤ 9.10 % and ≤ 7.58 %, respectively. The accuracy ranged between 92.59 % and 103.06 %. The method was successfully applied to the pharmacokinetic study of a subject who received a single oral dose (0.3 mg/kg) of immediate-release MPH and yielded consistent results with that of the GC-MS method. This method is the first HPLC assay with non-MS detection providing sufficient reliability and sensitivity for both pre-clinical and clinical studies of MPH. PMID:17804308

  1. Comparison of transferrin isoform analysis by capillary electrophoresis and HPLC for screening congenital disorders of glycosylation.

    PubMed

    Dave, Mihika B; Dherai, Alpa J; Udani, Vrajesh P; Hegde, Anaita U; Desai, Neelu A; Ashavaid, Tester F

    2018-01-01

    Transferrin, a major glycoprotein has different isoforms depending on the number of sialic acid residues present on its oligosaccharide chain. Genetic variants of transferrin as well as the primary (CDG) & secondary glycosylation defects lead to an altered transferrin pattern. Isoform analysis methods are based on charge/mass variations. We aimed to compare the performance of commercially available capillary electrophoresis CDT kit for diagnosing congenital disorders of glycosylation with our in-house optimized HPLC method for transferrin isoform analysis. The isoform pattern of 30 healthy controls & 50 CDG-suspected patients was determined by CE using a Carbohydrate-Deficient Transferrin kit. The results were compared with in-house HPLC-based assay for transferrin isoforms. Transferrin isoform pattern for healthy individuals showed a predominant tetrasialo transferrin fraction followed by pentasialo, trisialo, and disialotransferrin. Two of 50 CDG-suspected patients showed the presence of asialylated isoforms. The results were comparable with isoform pattern obtained by HPLC. The commercial controls showed a <20% CV for each isoform. Bland Altman plot showed the difference plot to be within +1.96 with no systemic bias in the test results by HPLC & CE. The CE method is rapid, reproducible and comparable with HPLC and can be used for screening Glycosylation defects. © 2017 Wiley Periodicals, Inc.

  2. HPLC & NMR-based forced degradation studies of ifosfamide: The potential of NMR in stability studies.

    PubMed

    Salman, D; Peron, J-M R; Goronga, T; Barton, S; Swinden, J; Nabhani-Gebara, S

    2016-03-01

    The aim of this study is to conduct a forced degradation study on ifosfamide under several stress conditions to investigate the robustness of the developed HPLC method. It also aims to provide further insight into the stability of ifosfamide and its degradation profile using both HPLC and NMR. Ifosfamide solutions (20mg/mL; n=15, 20mL) were stressed in triplicate by heating (70°C), under acidic (pH 1 & 4) and alkaline (pH 10 & 12) conditions. Samples were analysed periodically using HPLC and FT-NMR. Ifosfamide was most stable under weakly acidic conditions (pH 4). NMR results suggested that the mechanism of ifosfamide degradation involves the cleavage of the PN bond. For all stress conditions, HPLC was not able to detect ifosfamide degradation products that were detected by NMR. These results suggest that the developed HPLC method for ifosfamide did not detect the degradation products shown by NMR. It is possible that degradation products co-elute with ifosfamide, do not elute altogether or are not amenable to the detection method employed. Therefore, investigation of ifosfamide stability requires additional techniques that do not suffer from the aforementioned shortcomings. Copyright © 2015 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  3. A NEW HPLC METHOD FOR SEPARATION OF PHYTOPLANKTON PIGMENTS IN NATURAL SAMPLES

    EPA Science Inventory

    A new high-performance liquid chromatographic (HPLC) method was developed to analyze, in a single run, most polar and non-polar chlorophylls and carotenoids from marine phytoplankton. The method is based on a reverse-phase amide C16 (RP-amide C16) column and an elution gradient o...

  4. Determination of Urine Albumin by New Simple High-Performance Liquid Chromatography Method.

    PubMed

    Klapkova, Eva; Fortova, Magdalena; Prusa, Richard; Moravcova, Libuse; Kotaska, Karel

    2016-11-01

    A simple high-performance liquid chromatography (HPLC) method was developed for the determination of albumin in patients' urine samples without coeluting proteins and was compared with the immunoturbidimetric determination of albumin. Urine albumin is important biomarker in diabetic patients, but part of it is immuno-nonreactive. Albumin was determined by high-performance liquid chromatography (HPLC), UV detection at 280 nm, Zorbax 300SB-C3 column. Immunoturbidimetric analysis was performed using commercial kit on automatic biochemistry analyzer COBAS INTEGRA ® 400, Roche Diagnostics GmbH, Manheim, Germany. The HLPC method was fully validated. No significant interference with other proteins (transferrin, α-1-acid glycoprotein, α-1-antichymotrypsin, antitrypsin, hemopexin) was found. The results from 301 urine samples were compared with immunochemical determination. We found a statistically significant difference between these methods (P = 0.0001, Mann-Whitney test). New simple HPLC method was developed for the determination of urine albumin without coeluting proteins. Our data indicate that the HPLC method is highly specific and more sensitive than immunoturbidimetry. © 2016 Wiley Periodicals, Inc.

  5. Development and Optimisation of an HPLC-DAD-ESI-Q-ToF Method for the Determination of Phenolic Acids and Derivatives

    PubMed Central

    Restivo, Annalaura; Degano, Ilaria; Ribechini, Erika; Colombini, Maria Perla

    2014-01-01

    A method for the HPLC-MS/MS analysis of phenols, including phenolic acids and naphtoquinones, using an amide-embedded phase column was developed and compared to the literature methods based on classical C18 stationary phase columns. RP-Amide is a recently developed polar embedded stationary phase, whose wetting properties mean that up to 100% water can be used as an eluent. The increased retention and selectivity for polar compounds and the possibility of working in 100% water conditions make this column particularly interesting for the HPLC analysis of phenolic acids and derivatives. In this study, the chromatographic separation was optimised on an HPLC-DAD, and was used to separate 13 standard phenolic acids and derivatives. The method was validated on an HPLC-ESI-Q-ToF. The acquisition was performed in negative polarity and MS/MS target mode. Ionisation conditions and acquisition parameters for the Q-ToF detector were investigated by working on collision energies and fragmentor potentials. The performance of the method was fully evaluated on standards. Moreover, several raw materials containing phenols were analysed: walnut, gall, wine, malbec grape, French oak, red henna and propolis. Our method allowed us to characterize the phenolic composition in a wide range of matrices and to highlight possible matrix effects. PMID:24551158

  6. Development and Validation of a Simultaneous RP-HPLCUV/DAD Method for Determination of Polyphenols in Gels Containing S. terebinthifolius Raddi (Anacardiaceae)

    PubMed Central

    Carvalho, Melina G.; Aragão, Cícero F. S; Raffin, Fernanda N.; de L. Moura, Túlio F. A.

    2017-01-01

    Topical gels containing extracts of Schinus terebinthifolius have been used to treat bacterial vaginosis. It has been reported that this species has antimicrobial, anti-inflammatory and anti-ulcerogenic properties, which can be attributed to the presence of phenolic compounds. In this work, a sensitive and selective reversed-phase HPLC-UV/DAD method for the simultaneous assay of six polyphenols that could be present in S. terebinthifolius was developed. The method was shown to be accurate and precise. Peak purity and similarity index both exceeded 0.99. Calibration curves were linear over the concentration range studied, with correlation coefficients between 0.9931 and 0.9974. This method was used to determine the polyphenol content of a hydroalcoholic extract and pharmacy-compounded vaginal gel. Although the method is useful to assess the 6 phenolic compounds, some compounds could not be detected in the products. SUMMARY A sensitive, selective, accurate and precise reversed-phase HPLC-UV/DAD method for the simultaneous assay of six polyphenols in S. terebinthifolius Raddi Abbreviations used: RP-HPLC-UV/DAD: Reverse Phase High Performance Liquid Chromatograph with Ultraviolet and Diode Array Detector, HPLC: High Performance Liquid Chromatograph, HPLC-UV: High Performance Liquid Chromatograph with Ultraviolet Detector, ANVISA: Brazilian National Health Surveillance Agency, LOD: Limit of detection, LOQ: Limit of quantitation PMID:28539726

  7. Development of an Advanced HPLC-MS/MS Method for the Determination of Carotenoids and Fat-Soluble Vitamins in Human Plasma.

    PubMed

    Hrvolová, Barbora; Martínez-Huélamo, Miriam; Colmán-Martínez, Mariel; Hurtado-Barroso, Sara; Lamuela-Raventós, Rosa Maria; Kalina, Jiří

    2016-10-14

    The concentration of carotenoids and fat-soluble vitamins in human plasma may play a significant role in numerous chronic diseases such as age-related macular degeneration and some types of cancer. Although these compounds are of utmost interest for human health, methods for their simultaneous determination are scarce. A new high pressure liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) method for the quantification of selected carotenoids and fat-soluble vitamins in human plasma was developed, validated, and then applied in a pilot dietary intervention study with healthy volunteers. In 50 min, 16 analytes were separated with an excellent resolution and suitable MS signal intensity. The proposed HPLC-MS/MS method led to improvements in the limits of detection (LOD) and quantification (LOQ) for all analyzed compounds compared to the most often used HPLC-DAD methods, in some cases being more than 100-fold lower. LOD values were between 0.001 and 0.422 µg/mL and LOQ values ranged from 0.003 to 1.406 µg/mL, according to the analyte. The accuracy, precision, and stability met with the acceptance criteria of the AOAC (Association of Official Analytical Chemists) International. According to these results, the described HPLC-MS/MS method is adequately sensitive, repeatable and suitable for the large-scale analysis of compounds in biological fluids.

  8. Automated measurement of carbohydrate-deficient transferrin using the Bio-Rad %CDT by the HPLC test on a Variant HPLC system: evaluation and comparison with other routine procedures.

    PubMed

    Schellenberg, François; Mennetrey, Louise; Girre, Catherine; Nalpas, Bertrand; Pagès, Jean Christophe

    2008-01-01

    In this study, we evaluated the new %CDT by the HPLC method (Bio-Rad, Germany) on a Varianttrade mark HPLC system (Bio-Rad), checked the correlation with well-known methods and calculated the diagnostic value of the test. Intra-run and day-to-day precision values were calculated for samples with extreme serum transferrin concentrations, high trisialotransferrin and interfering conditions (haemolysed, lactescent and icteric samples). The method was compared with two routine procedures, the %CDT TIA (Bio-Rad, Hercules, CA, USA) and the Capillarystrade mark CDT (Sebia, France). A total of 350 clinical sera samples were used for a case-control study. Precision values were better in high CDT and medium CDT pools than in low CDT pools. The serum transferrin concentration had no effect on CDT measurement, except in samples with serum transferrin <1 g/L. Haemolysis was the only interfering situation. The method showed high correlation (r(2) > 0.95) with the two other methods (%CDT TIA and CZE %CDT). The global predictive value of the test was >0.90 at 1.9% cut-off. These results demonstrate that the %CDT by the HPLC test is suitable for CDT routine measurement; the results from the high-throughput Varianttrade mark system are well correlated with other methods and are of high diagnostic value.

  9. Comparative evaluation of three different ELISA assays and HPLC-ESI-ITMS/MS for the analysis of Nε-carboxymethyl lysine in food samples.

    PubMed

    Gómez-Ojeda, Armando; Jaramillo-Ortíz, Sarahi; Wrobel, Katarzyna; Wrobel, Kazimierz; Barbosa-Sabanero, Gloria; Luevano-Contreras, Claudia; de la Maza, Maria Pia; Uribarri, Jaime; Del Castillo, Ma Dolores; Garay-Sevilla, Ma Eugenia

    2018-03-15

    N ε -carboxymethyl-lysine (CML) is measured in food, but there is a controversy concerning the most convenient yet reliable method(s) for this task. This work compares three different ELISA assays and HPLC-ESI-ITMS/MS for the analysis of CML in several food items. The four methods showed the same decreasing order of CML concentration: beef, bacon>chicken > fish>dairy products>grain products>fruits/vegetables. HPLC-ESI-ITMS/MS results highly correlated with those obtained by ELISA performed with monoclonal CML-antibody (β=0.98, p<0.0001) whereas My Bio Source® kit results were not correlated with those provided by Lamider®. Small differences of CML concentrations in food items prepared by different culinary treatment were clearly distinguished by HPLC-ESI-ITMS/MS, but could not always be detected by ELISA. This work demonstrates a reasonable relationship between CM determined by ELISA and HPLC-ESI-ITMS/MS and therefore supports the implementation of ELISA in food CML/AGEs screening. Copyright © 2017. Published by Elsevier Ltd.

  10. Capillary electrophoresis with laser-induced fluorescence detection: a sensitive method for monitoring extracellular concentrations of amino acids in the periaqueductal grey matter.

    PubMed

    Bergquist, J; Vona, M J; Stiller, C O; O'Connor, W T; Falkenberg, T; Ekman, R

    1996-03-01

    The use of capillary electrophoresis with laser-induced fluorescence detection (CE-LIF) for the analysis of microdialysate samples from the periaqueductal grey matter (PAG) of freely moving rats is described. By employing 3-(4-carboxybenzoyl)-2-quinoline-carboxaldehyde (CBQCA) as a derivatization agent, we simultaneously monitored the concentrations of 8 amino acids (arginine, glutamine, valine, gamma-amino-n-butyric acid (GABA), alanine, glycine, glutamate, and aspartate), with nanomolar and subnanomolar detection limits. Two of the amino acids (GABA and glutamate) were analysed in parallel by conventional high-performance liquid chromatography (HPLC) in order to directly compare the two analytical methods. Other CE methods for analysis of microdialysate have been previously described, and this improved method offers greater sensitivity, ease of use, and the possibility to monitor several amino acids simultaneously. By using this technique together with an optimised form of microdialysis technique, the tiny sample consumption and the improved detection limits permit the detection of fast and transient transmitter changes.

  11. Measurement of menadione in urine by HPLC

    USDA-ARS?s Scientific Manuscript database

    Mammals convert phylloquinone to MK-4, with menadione as a possible intermediate. We developed and validated a method measuring urinary menadione. A high performance liquid chromatography (HPLC) method with a C30 column, fluorescence detection and post-column zinc reduction was developed. The mobile...

  12. HPLC: Early and Recent Perspectives.

    ERIC Educational Resources Information Center

    Karger, Barry L.

    1997-01-01

    Provides a perspective on what it was like in the early days of high-performance liquid chromatography (HPLC) and several of the key developments. Focuses on the advances in HPLC generally, and more specifically for the biological sciences, that were necessary for the method to reach the preeminent stage of today. Contains 20 references. (JRH)

  13. Major and Modified Nucleosides, RNA, and DNA

    NASA Astrophysics Data System (ADS)

    Gehrke, Charles W.; Kuo, Kenneth C.

    Most analytical chemists are well aware of the rapid rate of development of high-performance liquid chromatography (HPLC) over the past 5 years. A number of articles have been published in Analytical Chemistry on different topics in HPLC and many papers appear in the chromatographic journals. Some books also have been published covering this subject. HPLC has proved to be a very effective, broadly applicable chromatographic method for the separation and analysis of complex molecules in fields as diverse as biochemistry and environmental, pharmaceutical, medical, and polymer chemistry. HPLC is now having a major impact on the clinical and research aspects of medical biochemistry. Although the contributions of HPLC to other disciplines generally complements gas-liquid chromatography, this method is destined to play a much greater role in medical and biochemical research. This is because many of the biomolecules, owing to their molecular complexity and size, are thermally unstable or nonvolatile, preventing or complicating an analysis by GC. A major factor contributing to the powerful advances in biomedical liquid chromatography is the development of reversed-phase high-performance liquid chromatography (RP-HPLC) using n-alkyl and phenyl chemically bonded substrates.

  14. Infrared-Assisted Extraction and HPLC-Analysis of Prunus armeniaca L. Pomace and Detoxified-Kernel and their Antidiabetic Effects.

    PubMed

    Raafat, Karim; El-Darra, Nada; Saleh, Fatima A; Rajha, Hiba N; Maroun, Richard G; Louka, Nicolas

    2018-03-01

    Prunus armeniaca L. (P. armeniaca) is one of the medicinal plants with a high safety-profile. The aim of this work was to make an infrared-assisted extraction (IR-AE) of P. armeniaca fruit (pomace) and kernel, and analyse them using reverse phase high-performance liquid chromatography (RP-HPLC) aided method. IR-AE is a novel-technique aimed at increasing the extraction-efficiency. The antidiabetic-potentials of the P. armeniaca pomace (AP) and the detoxified P. armeniaca kernel extract (DKAP) were monitored exploring their possible hypoglycemic-mechanisms. Acute (6 h), subchronic (8 days) and long-term (8 weeks) assessment of Diabetes mellitus (DM) using glucometers and glycated hemoglobin (HbA1c) methods were applied. Serum-insulin levels, the inhibitory effects on alpha-glucosidase, serum-catalase (CAT) and lipid peroxidation (LPO) levels were also monitored. AP was shown to be rich in polyphenolics like trans-lutein (14.1%), trans-zeaxanthin (10.5%), trans-ß-cryptoxanthin (11.6%), 13, cis-ß-carotene (6.5%), trans 9, cis-ß-carotene (18.4%), and ß-carotene (21.5%). Prunus armeniaca kernel extract before detoxification (KAP) was found to be rich in amygdaline (16.1%), which caused a high mortality rate (50.1%), while after detoxification (amygdaline, 1.4%) a lower mortality rate (9.1%) was found. AP showed significant (p ≤ 0.05, n = 7/group) antidiabetic-activity more prominent than DKAP acutely, subchronically and on longer-terms. IR-AEs displayed more efficient acute and subchronic blood glucose level (BGL) reduction than a conventional extraction method, which might be attributed to IR-AE superiority in extraction of active ingredients. AP showed more-significant and dose-dependent increase in serum-insulin, CAT-levels and body-weights more prominent than those of DKAP. Alpha-glucosidase and LPO levels were inhibited with AP-groups more-significantly. In comparison to conventional-methods, IR-AE appeared to be an efficient and time-conserving novel extraction method. The antidiabetic-potentials of pomace and detoxified-kernels of P. armeniaca were probably mediated via the attenuation of glucose-provoked oxidative-stress, the inhibition of alpha-glucosidase and the marked insulin-secretagogue effect. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  15. The effect of different conventional methods of extraction on Marantodes pumila var. pumila leaves in relation to free radical scavenging activity

    NASA Astrophysics Data System (ADS)

    Hamid, Noor Huda Abd; Latip, Jalifah; Markom, Masturah

    2018-04-01

    Marantodes pumila is one of the important herbs used in traditional medicine. However, there is no report on the optimum method for the preparation of M. pumila extract enriched with bioactive compounds. Therefore, this study aim to establish the suitable method in the preparation of M. pumila extracts enriched with antioxidative compounds. Different conventional extraction methods such as maceration, reflux and Soxhlet in solvents of different polarities i.e. ethanol, 50 % aqueous ethanol and water were employed to prepare extracts. Constituents of each extract were profiled using RP-HPLC followed by the free radical scavenging assay using 2,2 diphenyl-1-picrylhydrazyl (DPPH) to determine the antioxidant activity. Among all extraction methods, maceration in 50 % aqueous ethanol gave the highest total percentage yield (22.41 %) while all extraction methods were able to extract the marker compounds, gallic acid (GA) and methyl gallate (MGA). The free radical scavenging activity of extracts varied from IC50 11.93 µg/mL (50 % aqueous ethanol via reflux) to 64.15 µg/mL (water via maceration). All extracts showed better scavenging activity as compared to synthetic antioxidant, BHT. The variation in the IC50 values is expected due to the presence of different types and/or concentration of bioactive compounds in each extract. This study may provide a preliminary insight for the preparation of standardized extracts of M. pumila enriched with bioactive compounds.

  16. Enhanced separation and analysis procedure reveals production of tri-acylated mannosylerythritol lipids by Pseudozyma aphidis.

    PubMed

    Goossens, Eliane; Wijnants, Marc; Packet, Dirk; Lemière, Filip

    2016-11-01

    Mannosylerythritol lipids (MELs) are one of the most promising biosurfactants because of their high fermentation yields (>100 g l -1 ) and during the last two decades they have gained a lot of attention due to their interesting self-assembling properties and biological activities. In this study, MELs were produced by fed-batch bioreactor fermentation of rapeseed oil with Pseudozyma aphidis MUCL 27852. This high-level MEL-producing yeast secretes four conventional MEL structures, -A, -B, -C and -D, which differ in their degree of acetylation. During our research, unknown compounds synthesized by P. aphidis were detected by thin-layer chromatography. The unknown compounds were separated by flash chromatography and identified as tri-acylated MELs by high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS). The third fatty acid chain on the tri-acylated MELs was positioned on the primary alcohol of the erythritol moiety and comprised long-chain acids, mainly oleic and linoleic acid, which are not found in conventional di-acylated MELs. Furthermore, the LC-MS analysis time of conventional MELs was reduced to almost one-third by switching from HPLC-MS/MS to ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). Provided optimization of the fermentation yield, P. aphidis could be an interesting novel producer of tri-acylated MELs and, thereby expand the supply and applicability of biosurfactants.

  17. Monitoring of monosaccharides, oligosaccharides, ethanol and glycerol during wort fermentation by biosensors, HPLC and spectrophotometry.

    PubMed

    Monošík, Rastislav; Magdolen, Peter; Stredanský, Miroslav; Šturdík, Ernest

    2013-05-01

    The aim of the present study was to analyze sugar levels (namely maltose, maltotriose, glucose and fructose) and alcohols (ethanol and glycerol) during the fermentation process in wort samples by amperometric enzymatic biosensors developed by our research group for industrial application, HPLC and spectrophotometry, and to compare the suitability of the presented methods for determination of individual analytes. We can conclude that for the specific monitoring of maltose or maltotriose only the HPLC method was suitable. On the other hand, biosensors and spectrophotometry reflected a decrease in total sugar concentration better and were able to detect both glucose and fructose in the later stages of fermentation, while HPLC was not. This can be attributed to the low detection limits and good sensitivity of the proposed methods. For the ethanol and glycerol analysis all methods proved to be suitable. However, concerning the cost expenses and time analysis, biosensors represented the best option. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Rapid NMR method for the quantification of organic compounds in thin stillage.

    PubMed

    Ratanapariyanuch, Kornsulee; Shen, Jianheng; Jia, Yunhua; Tyler, Robert T; Shim, Youn Young; Reaney, Martin J T

    2011-10-12

    Thin stillage contains organic and inorganic compounds, some of which may be valuable fermentation coproducts. This study describes a thorough analysis of the major solutes present in thin stillage as revealed by NMR and HPLC. The concentration of charged and neutral organic compounds in thin stillage was determined by excitation sculpting NMR methods (double pulse field gradient spin echo). Compounds identified by NMR included isopropanol, ethanol, lactic acid, 1,3-propanediol, acetic acid, succinic acid, glycerophosphorylcholine, betaine, glycerol, and 2-phenylethanol. The concentrations of lactic and acetic acid determined with NMR were comparable to those determined using HPLC. HPLC and NMR were complementary, as more compounds were identified using both methods. NMR analysis revealed that stillage contained the nitrogenous organic compounds betaine and glycerophosphorylcholine, which contributed as much as 24% of the nitrogen present in the stillage. These compounds were not observed by HPLC analysis.

  19. The analysis of carbohydrates in milk powder by a new "heart-cutting" two-dimensional liquid chromatography method.

    PubMed

    Ma, Jing; Hou, Xiaofang; Zhang, Bing; Wang, Yunan; He, Langchong

    2014-03-01

    In this study, a new"heart-cutting" two-dimensional liquid chromatography method for the simultaneous determination of carbohydrate contents in milk powder was presented. In this two dimensional liquid chromatography system, a Venusil XBP-C4 analysis column was used in the first dimension ((1)D) as a pre-separation column, a ZORBAX carbohydrates analysis column was used in the second dimension ((2)D) as a final-analysis column. The whole process was completed in less than 35min without a particular sample preparation procedure. The capability of the new two dimensional HPLC method was demonstrated in the determination of carbohydrates in various brands of milk powder samples. A conventional one dimensional chromatography method was also proposed. The two proposed methods were both validated in terms of linearity, limits of detection, accuracy and precision. The comparison between the results obtained with the two methods showed that the new and completely automated two dimensional liquid chromatography method is more suitable for milk powder sample because of its online cleanup effect involved. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  20. Detection of honey adulteration with starch syrup by high performance liquid chromatography.

    PubMed

    Wang, Shaoqing; Guo, Qilei; Wang, Linlin; Lin, Li; Shi, Hailiang; Cao, Hong; Cao, Baosen

    2015-04-01

    According to saccharide profile comparison between starch syrups and pure honeys analysed through high performance liquid chromatography (HPLC), a characteristic peak was found at 15.25 min retention time in HPLC chromatogram of syrup, but no peak was observed at the same retention time in chromatogram of pure honeys. This characteristic peak for syrup was identified as an overlapping peak of oligosaccharides with more than 5 degree of polymerisation (DP) based on HPLC chromatogram comparison between starch syrup and a series of standard mono-, di- and oligosaccharides of 3-7 DP. Additionally syrup content correlated linearly with the height of the characteristic peak of syrup under different slope in two ranges 2.5-7.5% and 10-100%, respectively. Therefore, the characteristic peak at 15.25 min retention time can serve as a syrup indicator in HPLC analysis of the adulterated honeys. This new HPLC method for honey adulteration detection was further applied in an authenticity inspection on more than 100 commercial honeys. In addition to the improved accuracy of honey adulteration detection, the proposed HPLC method was simple, low cost and easy practice for honey product quality control by government department considering the popularity of HPLC device and technology. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Determination of Trace Elements in Uranium by HPLC-ID-ICP-MS: NTNFC Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manard, Benjamin Thomas; Wylie, Ernest Miller II; Xu, Ning

    This report covers the FY 16 effort for the HPLC-ID-ICP-MS methodology 1) sub-method validation for the group I&II elements, 2) sub-method stood-up and validation for REE, 3) sub-method development for the transition element, and 4) completion of a comprehensive SOP for three families of elements.

  2. Identification and anti-oxidant capacity determination of phenolics and their glycosides in elderflower by on-line HPLC-CUPRAC method.

    PubMed

    Çelik, S Esin; Özyürek, Mustafa; Güçlü, Kubilay; Çapanoğlu, Esra; Apak, Reşat

    2014-01-01

    Development and application of an on-line cupric reducing anti-oxidant capacity (CUPRAC) assay coupled with HPLC for separation and on-line determination of phenolic anti-oxidants in elderflower (Sambucus nigra L.) extracts for their anti-oxidant capacity are significant for evaluating health-beneficial effects. Moreover, this work aimed to assay certain flavonoid glycosides of elderflower that could not be identified/quantified by other similar on-line HPLC methods (i.e. 2,2-diphenyl-1-picrylhdrazyl and 2, 2'-azino-bis-3-ethylbenzothiazoline-6-sulphonic acid). To identify anti-oxidant constituents in elderflower by HPLC and to evaluate their individual anti-oxidant capacities by on-line HPLC-CUPRAC assay with a post-column derivatisation system. The separation and UV detection of polyphenols were performed on a C18 -column using gradient elution with two different mobile phase solutions, that is acetonitrile and 1% glacial acetic acid, with detection at 340 nm. The HPLC-separated anti-oxidant polyphenols in column effluent react with copper(II)-neocuproine in a reaction-coil to reduce the latter to copper(I)-neocuproine (Cu(I)-Nc) chelate having maximum absorption at 450 nm. The detection limits of tested compounds at 450 nm after post-column derivatisation were compared with those of at 340 nm UV-detection without derivatisation. LOD values (µg/mL) of quercetin and its glycosides at 450 nm were lower than those of UV detection at 340 nm. This method was applied successfully to elderflower extract. The flavonol glycosides of quercetin and kaempferol bound to several sugar components (glucose, rhamnose, galactose and rutinose) were identified in the sample. The on-line HPLC-CUPRAC method was advantageous over on-line ABTS and DPPH methods for measuring the flavonoid glycosides of elderflower. Copyright © 2014 John Wiley & Sons, Ltd.

  3. Comparison of Peak-area Ratios and Percentage Peak Area Derived from HPLC-evaporative Light Scattering and Refractive Index Detectors for Palm Oil and its Fractions.

    PubMed

    Ping, Bonnie Tay Yen; Aziz, Haliza Abdul; Idris, Zainab

    2018-01-01

    High-Performance Liquid Chromatography (HPLC) methods via evaporative light scattering (ELS) and refractive index (RI) detectors are used by the local palm oil industry to monitor the TAG profiles of palm oil and its fractions. The quantitation method used is based on area normalization of the TAG components and expressed as percentage area. Although not frequently used, peak-area ratios based on TAG profiles are a possible qualitative method for characterizing the TAG of palm oil and its fractions. This paper aims to compare these two detectors in terms of peak-area ratio, percentage peak area composition, and TAG elution profiles. The triacylglycerol (TAG) composition for palm oil and its fractions were analysed under similar HPLC conditions i.e. mobile phase and column. However, different sample concentrations were used for the detectors while remaining within the linearity limits of the detectors. These concentrations also gave a good baseline resolved separation for all the TAGs components. The results of the ELSD method's percentage area composition for the TAGs of palm oil and its fractions differed from those of RID. This indicates an unequal response of TAGs for palm oil and its fractions using the ELSD, also affecting the peak area ratios. They were found not to be equivalent to those obtained using the HPLC-RID. The ELSD method showed a better baseline separation for the TAGs components, with a more stable baseline as compared with the corresponding HPLC-RID. In conclusion, the percentage area compositions and peak-area ratios for palm oil and its fractions as derived from HPLC-ELSD and RID were not equivalent due to different responses of TAG components to the ELSD detector. The HPLC-RID has a better accuracy for percentage area composition and peak-area ratio because the TAG components response equally to the detector.

  4. Determination of rivaroxaban in patient's plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS).

    PubMed

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo Dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels.

  5. A novel reversed-phase HPLC method for the determination of urinary creatinine by pre-column derivatization with ethyl chloroformate: comparative studies with the standard Jaffé and isotope-dilution mass spectrometric assays.

    PubMed

    Leung, Elvis M K; Chan, Wan

    2014-02-01

    Creatinine is an important biomarker for renal function diagnosis and normalizing variations in urinary drug/metabolites concentration. Quantification of creatinine in biological fluids such as urine and plasma is important for clinical diagnosis as well as in biomonitoring programs and urinary metabolomics/metabonomics research. Current methods for creatinine determination either are nonselective or involve the use of expensive mass spectrometers. In this paper, a novel reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of creatinine of high hydrophilicity by pre-column derivatization with ethyl chloroformate is presented. N-Ethyloxycarbonylation of creatinine significantly enhanced the hydrophobicity of creatinine, facilitating its chromatographic retention as well as quantification by HPLC. Factors governing the derivatization reaction were studied and optimized. The developed method was validated and applied for the determination of creatinine in rat urine samples. Comparative studies with isotope-dilution mass spectrometric method revealed that the two methods do not yield systematic differences in creatinine concentrations, indicating the HPLC method is suitable for the determination of creatinine in urine samples.

  6. A thin film degradation study of a fluorinated polyether liquid lubricant using an HPLC method

    NASA Technical Reports Server (NTRS)

    Morales, W.

    1986-01-01

    A High Pressure Liquid Chromatography (HPLC) separation method was developed to study and analyze a fluorinated polyether fluid which is promising liquid lubricant for future applications. This HPLC separation method was used in a preliminary study investigating the catalytic effect of various metal, metal alloy, and ceramic engineering materials on the degradation of this fluid in a dry air atmosphere at 345 C. Using a 440 C stainless steel as a reference catalytic material it was found that a titanium alloy and a chromium plated material degraded the fluorinated polyether fluid substantially more than the reference material.

  7. Determination of Bortezomib in API Samples Using HPLC: Assessment of Enantiomeric and Diastereomeric Impurities.

    PubMed

    Kamalzadeh, Zahra; Babanezhad, Esmaeil; Ghaffari, Solmaz; Mohseni Ezhiyeh, Alireza; Mohammadnejad, Mahdieh; Naghibfar, Mehdi; Bararjanian, Morteza; Attar, Hossein

    2017-08-01

    A new, normal phase high performance liquid chromatography (NP-HPLC) method was developed for separation of Bortezomib (BZB) enantiomers and quantitative determination of (1S,2R)-enantiomer of BZB in active pharmaceutical ingredient (API) samples. The developed method was validated based on International Conference on Harmonisation (ICH) guidelines and it was proved to be accurate, precise and robust. The obtained resolution (RS) between the enantiomers was more than 2. The calibration curve for (1S,2R)-enantiomer was found to be linear in the concentration range of 0.24-5.36 mg/L with regression coefficient (R2) of 0.9998. Additionally, the limit of detection (LOD) and limit of quantification (LOQ) were 0.052 and 0.16 mg/L, respectively. Also, in this study, a precise, sensitive and robust gradient reversed-phase HPLC (RP-HPLC) method was developed and validated for determination of BZB in API samples. The detector response was linear over the concentration range of 0.26-1110.5 mg/L. The values of R2, LOD and LOQ were 0.9999, 0.084 and 0.25 mg/L, respectively. For both NP-HPLC and RP-HPLC methods, all of the RSD (%) values obtained in the precision study were <1.0%. System suitability parameters in terms of tailing factor (TF), number of theoretical plates (N) and RS were TF < 2.0, N > 2,000 and RS > 2.0. The performance of two common integration methods of valley to valley and drop perpendicular for drawing the baseline between two adjacent peaks were investigated for the determination of diastereomeric impurity (Imp-D) in the BZB-API samples. The results showed that the valley to valley method outperform the drop perpendicular method for calculation of Imp-D peak areas. Therefore, valley to valley method was chosen for peak integration. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Antioxidant components of Viburnum opulus L. determined by on-line HPLC-UV-ABTS radical scavenging and LC-UV-ESI-MS methods.

    PubMed

    Karaçelik, Ayça Aktaş; Küçük, Murat; İskefiyeli, Zeynep; Aydemir, Sezgin; De Smet, Seppe; Miserez, Bram; Sandra, Patrick

    2015-05-15

    Antioxidant activity of the juice and seed and skin extracts prepared with methanol, acetonitrile, and water of Viburnum opulus L. grown in Eastern Black Sea Region were studied with an on-line HPLC-ABTS method and off-line antioxidant methods, among which a linear positive correlation was observed. The fruit extracts were analysed with the HPLC-UV method optimised with 14 standard phenolics. Identification of the phenolic components in the juice was made using an HPLC-UV-ESI-MS method. Nineteen phenolic compounds in juice were identified by comparing the retention times and mass spectra with those of the standards and the phenolics reported in the literature. The major peaks in the juice belonged to coumaroyl-quinic acid, chlorogenic acid, procyanidin B2, and procyanidin trimer. Quite different antioxidant composition profiles were obtained from the extracts with the solvents of different polarities. The antioxidant activities of the seed extracts were higher than those of the skin extracts in general. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Determination and removal of antibiotics in secondary effluent using a horizontal subsurface flow constructed wetland.

    PubMed

    Zhang, Chunhui; Ning, Ke; Zhang, Wenwen; Guo, Yuanjie; Chen, Jun; Liang, Chen

    2013-04-01

    Increased attention is currently being directed towards the potential negative effects of antibiotics and other PPCPs discharged into the aquatic environment via municipal WWTP secondary effluents. A number of analytical methods, such as high performance liquid chromatography technologies, including a high performance liquid chromatography-fluorescence method (HPLC-FLD), high performance liquid chromatography-UV detection method (HPLC-UV) and high performance liquid chromatography-mass spectrometry method (HPLC-MS), have been suggested as determination technologies for antibiotic residues in water. In this study, we implement a HPLC-MS/MS combined method to detect and analyze antibiotics in WWTP secondary effluent and apply a horizontal subsurface flow constructed wetland (CW) as an advanced wastewater treatment for removing antibiotics in the WWTP secondary effluent. The results show that there were 2 macrolides, 2 quinolones and 5 sulfas in WWTP secondary effluent among all the 22 antibiotics considered. After the CW advanced treatment, the concentration removal efficiencies and removal loads of 9 antibiotics were 53-100% and 0.004-0.7307 μg m(-2) per day, respectively.

  10. A PLS-based extractive spectrophotometric method for simultaneous determination of carbamazepine and carbamazepine-10,11-epoxide in plasma and comparison with HPLC

    NASA Astrophysics Data System (ADS)

    Hemmateenejad, Bahram; Rezaei, Zahra; Khabnadideh, Soghra; Saffari, Maryam

    2007-11-01

    Carbamazepine (CBZ) undergoes enzyme biotransformation through epoxidation with the formation of its metabolite, carbamazepine-10,11-epoxide (CBZE). A simple chemometrics-assisted spectrophotometric method has been proposed for simultaneous determination of CBZ and CBZE in plasma. A liquid extraction procedure was operated to separate the analytes from plasma, and the UV absorbance spectra of the resultant solutions were subjected to partial least squares (PLS) regression. The optimum number of PLS latent variables was selected according to the PRESS values of leave-one-out cross-validation. A HPLC method was also employed for comparison. The respective mean recoveries for analysis of CBZ and CBZE in synthetic mixtures were 102.57 (±0.25)% and 103.00 (±0.09)% for PLS and 99.40 (±0.15)% and 102.20 (±0.02)%. The concentrations of CBZ and CBZE were also determined in five patients using the PLS and HPLC methods. The results showed that the data obtained by PLS were comparable with those obtained by HPLC method.

  11. ANALYSIS OF SELECTED PYRETHROID PESTICIDES USING REVERSE PHASE HIGH PRESSURE LIQUID CHROMATOGRAPHY/UV

    EPA Science Inventory

    This research was conducted in cooperation with EPA Region 4 in Athens, GA to develop a method to analyze selected pyrethroid pesticides using Reverse Phase-High Pressure Liquid Chromatography (HPLC). This HPLC method will aid researchers in separating and identifying these py...

  12. Simultaneous determination of domperidone and Itopride in pharmaceuticals and human plasma using RP-HPLC/UV detection: Method development, validation and application of the method in in-vivo evaluation of fast dispersible tablets.

    PubMed

    Khan, Amjad; Iqbal, Zafar; Khadra, Ibrahim; Ahmad, Lateef; Khan, Abad; Khan, Muhammad Imran; Ullah, Zia; Ismail

    2016-03-20

    Domperidone and Itopride are pro-kinetic agents, regulating the gastric motility and are commonly prescribed as anti emetic drugs. In the present study a simple, rapid and sensitive RP-HPLC/UV method was developed for simultaneous determination of Domperidone and Itopride in pharmaceutical samples and human plasma, using Tenofavir as internal standard. Experimental conditions were optimized and method was validated according to the standard guidelines. Combination of water (pH 3.0) and acetonitrile (65:35 v/v) was used as mobile phase, pumped at the flow rate of 1.5 ml/min. Detector wavelength was set at 210 nm and column oven temperature was 40oC. Unlike conventional liquid-liquid extraction, simple precipitation technique was applied for drug extraction from human plasma using acetonitrile for deprotienation. The method showed adequate separation of both the analytes and best resolution was achieved using Hypersil BDS C8 column (150 mm × 4.6 mm, 5 μm). The method was quite linear in the range of 20-600 ng/ml. Recovery of the method was 92.31% and 89.82% for Domperidone and Itopride, respectively. Retention time of both the analytes and internal standard was below 15 min. The lower limit of detection (LLOD) and lower limit of quantification (LLOQ) for Domperidone were 5 and 10 ng/ml while for Itopride was 12 and 15 ng/ml, respectively. The developed method was successfully applied for in-vivo analysis of fast dispersible tablets of Domperidone in healthy human volunteer. The proposed method was a part of formulation development study and was efficiently applied for determination of the two drugs in various pharmaceutical products and human plasma. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. 40 CFR Appendix A to Subpart C of... - Alternative Testing Methods Approved for Analyses Under the Safe Drinking Water Act

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Chromatography/Mass Spectrometry (GC/MS) 525.3 24 Carbofuran High-performance liquid chromatography (HPLC) with... (HPLC) with Post-Column Derivatization and Fluorescence Detection 6651 B 6651 B 6651 B-00. Heptachlor... Spectrometry (GC/MS) 525.3 24 Oxamyl High-performance liquid chromatography (HPLC) with post-column...

  14. Quantitative analysis of major dibenzocyclooctane lignans in Schisandrae fructus by online TLC-DART-MS.

    PubMed

    Kim, Hye Jin; Oh, Myung Sook; Hong, Jongki; Jang, Young Pyo

    2011-01-01

    Direct analysis in real time (DART) ion source is a powerful ionising technique for the quick and easy detection of various organic molecules without any sample preparation steps, but the lack of quantitation capacity limits its extensive use in the field of phytochemical analysis. To improvise a new system which utilize DART-MS as a hyphenated detector for quantitation. A total extract of Schisandra chinensis fruit was analyzed on a TLC plate and three major lignan compounds were quantitated by three different methods of UV densitometry, TLC-DART-MS and HPLC-UV to compare the efficiency of each method. To introduce the TLC plate into the DART ion source at a constant velocity, a syringe pump was employed. The DART-MS total ion current chromatogram was recorded for the entire TLC plate. The concentration of each lignan compound was calculated from the calibration curve established with standard compound. Gomisin A, gomisin N and schisandrin were well separated on a silica-coated TLC plate and the specific ion current chromatograms were successfully acquired from the TLC-DART-MS system. The TLC-DART-MS system for the quantitation of natural products showed better linearity and specificity than TLC densitometry, and consumed less time and solvent than conventional HPLC method. A hyphenated system for the quantitation of phytochemicals from crude herbal drugs was successfully established. This system was shown to have a powerful analytical capacity for the prompt and efficient quantitation of natural products from crude drugs. Copyright © 2010 John Wiley & Sons, Ltd.

  15. Preparative isolation and purification of indigo and indirubin from Folium isatidis by high-speed counter-current chromatography.

    PubMed

    Lü, Hai-tao; Liu, Jing; Deng, Rui; Song, Ji-ying

    2012-01-01

    Indigo and indirubin are the main active ingredients found in traditional Chinese herbal medicine Folium isatidis. An effective method for the isolation and purification of indigo and indirubin from Folium isatidis is needed. Compared with the conventional column chromatographic techniques, high-speed counter-current chromatography (HSCCC) is a suitable alternative for the enrichment and purification of these target compounds, and eliminates the complications resulting from a solid support matrix. To develop a reliable HSCCC method for isolation and identification of indigo and indirubin in a one-step separation from Folium isatidis. The optimum extracting conditions of indigo and indirubin from Folium isatidis were investigated by orthogonal test L(16) (4(5)). The target compounds were isolated and purified with a solvent system of n-hexane:ethyl acetate:ethanol:water (1:1:1:1, v/v) and the lower phase was used as the mobile phase in the head-to-tail elution mode. The purities of target compounds were tested by HPLC and their structures were identified by UV, IR, electrospray ion source (ESI)-MS, (1) H-NMR and (13) C-NMR analyses. From 165 mg of the crude extract, 5.65 mg of indigo and 1.00 mg of indirubin were obtained by HPLC analysis with purities of 98.4% and 99.0% respectively, and their mean recoveries were 91.0% and 90.7%, respectively. The HSCCC method is effective for the preparative separation and purification of indigo and indirubin in a one-step separation from Folium isatidis. Copyright © 2012 John Wiley & Sons, Ltd.

  16. Determination of Three Corticosteroids in the Biologic Matrix of Vitreous Humor by HPLC-tandem Mass Spectrometry: Method Development and Validation.

    PubMed

    Prieto, Esther; Vispe, Eugenio; Otín-Mallada, Sofía; Garcia-Martin, Elena; Polo-Llorens, Vicente; Fraile, José M; Pablo, Luis E; Mayoral, José A

    2017-02-01

    To develop a simple, specific, and rapid method to determine corticosteroid concentrations in vitreous humor. An analytical method based on high-pressure liquid chromatography-tandem mass spectrometry (HPLC-MS) with a simple extraction procedure was developed. New Zealand albino rabbits (n = 54) received a single (0.1 mL) intravitreal injection of dexamethasone (DXM, 0.1 mg), methylprednisolone (MP, 2 mg), or triamcinolone acetonide (TA, 10 mg). Eyes were enucleated and mean vitreous steroid levels were quantified at 12 h and 1, 2, 3, 7, and 14 days. Corticosteroids were extracted from the vitreous with acetonitrile, and TA was extracted with ethyl acetate, yielding high protein precipitation and clean solution samples. Vitreous samples were analyzed by isocratic HPLC-MS with mobile phase comprising acetonitrile and 2 mM ammonium formate buffer in water, pH 3.5. The linear range was 50-100,000 ng/g with a lower quantification limit of 45 ng/g for DXM and MP, and 50 ng/g for TA. Vitreous levels of DXM and MP were not detectable 14 days post-administration. Vitreous levels of TA were positive and stable throughout the study in both injected and control eyes. The HPLC-MS analytical method is an alternative to HPLC-MS/MS methods, sensitive enough for identifying and quantifying steroids in vitreous humor at a therapeutic dosage scale.

  17. Chemical Differentiation of Dendrobium officinale and Dendrobium devonianum by Using HPLC Fingerprints, HPLC-ESI-MS, and HPTLC Analyses

    PubMed Central

    Ye, Zi; Dai, Jia-Rong; Zhang, Cheng-Gang; Lu, Ye; Wu, Lei-Lei; Gong, Amy G. W.; Wang, Zheng-Tao

    2017-01-01

    The stems of Dendrobium officinale Kimura et Migo (Dendrobii Officinalis Caulis) have a high medicinal value as a traditional Chinese medicine (TCM). Because of the limited supply, D. officinale is a high priced TCM, and therefore adulterants are commonly found in the herbal market. The dried stems of a closely related Dendrobium species, Dendrobium devonianum Paxt., are commonly used as the substitute; however, there is no effective method to distinguish the two Dendrobium species. Here, a high performance liquid chromatography (HPLC) method was successfully developed and applied to differentiate D. officinale and D. devonianum by comparing the chromatograms according to the characteristic peaks. A HPLC coupled with electrospray ionization multistage mass spectrometry (HPLC-ESI-MS) method was further applied for structural elucidation of 15 flavonoids, 5 phenolic acids, and 1 lignan in D. officinale. Among these flavonoids, 4 flavonoid C-glycosides were firstly reported in D. officinale, and violanthin and isoviolanthin were identified to be specific for D. officinale compared with D. devonianum. Then, two representative components were used as chemical markers. A rapid and reliable high performance thin layer chromatography (HPTLC) method was applied in distinguishing D. officinale from D. devonianum. The results of this work have demonstrated that these developed analytical methods can be used to discriminate D. officinale and D. devonianum effectively and conveniently. PMID:28769988

  18. HPLC-based quantification of bacterial housekeeping nucleotides and alarmone messengers ppGpp and pppGpp.

    PubMed

    Varik, Vallo; Oliveira, Sofia Raquel Alves; Hauryliuk, Vasili; Tenson, Tanel

    2017-09-08

    Here we describe an HPLC-based method to quantify bacterial housekeeping nucleotides and the signaling messengers ppGpp and pppGpp. We have replicated and tested several previously reported HPLC-based approaches and assembled a method that can process 50 samples in three days, thus making kinetically resolved experiments feasible. The method combines cell harvesting by rapid filtration, followed by acid extraction, freeze-drying with chromatographic separation. We use a combination of C18 IPRP-HPLC (GMP unresolved and co-migrating with IMP; GDP and GTP; AMP, ADP and ATP; CTP; UTP) and SAX-HPLC in isocratic mode (ppGpp and pppGpp) with UV detection. The approach is applicable to bacteria without the requirement of metabolic labelling with 32P-labelled radioactive precursors. We applied our method to quantify nucleotide pools in Escherichia coli BW25113 K12-strain both throughout the growth curve and during acute stringent response induced by mupirocin. While ppGpp and pppGpp levels vary drastically (40- and ≥8-fold, respectively) these changes are decoupled from the quotients of the housekeeping pool and guanosine and adenosine housekeeping nucleotides: NTP/NDP/NMP ratio remains stable at 6/1/0.3 during both normal batch culture growth and upon acute amino acid starvation.

  19. Quantitative Determination of Fluorinated Caffeic Acid Phenethyl Ester Derivative From Rat Blood Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry

    DTIC Science & Technology

    2008-03-06

    Caffeic acid phenethyl ester (CAPE), a plant-derived polyphenolic compound (Fig. 1), is a component of bee propolis . Propolis has been used as a folk...analytical methods have been documented. These include an HPLC-UV determination of CAPE from a propolis -containing gel [13], HPLC-ESI-MS measurement...of CAPE from crude propolis [14], and HPLC- ESI-MS/MS analysis of CAPE in biological samples [15]. In this paper, we developed a method using ultra

  20. Quantification of maltol in Korean ginseng (Panax ginseng) products by high-performance liquid chromatography-diode array detector

    PubMed Central

    Jeong, Hyun Cheol; Hong, Hee-Do; Kim, Young-Chan; Rhee, Young Kyoung; Choi, Sang Yoon; Kim, Kyung-Tack; Kim, Sung Soo; Lee, Young-Chul; Cho, Chang-Won

    2015-01-01

    Background: Maltol, as a type of phenolic compounds, is produced by the browning reaction during the high-temperature treatment of ginseng. Thus, maltol can be used as a marker for the quality control of various ginseng products manufactured by high-temperature treatment including red ginseng. For the quantification of maltol in Korean ginseng products, an effective high-performance liquid chromatography-diode array detector (HPLC-DAD) method was developed. Materials and Methods: The HPLC-DAD method for maltol quantification coupled with a liquid-liquid extraction (LLE) method was developed and validated in terms of linearity, precision, and accuracy. An HPLC separation was performed on a C18 column. Results: The LLE methods and HPLC running conditions for maltol quantification were optimized. The calibration curve of the maltol exhibited good linearity (R2 = 1.00). The limit of detection value of maltol was 0.26 μg/mL, and the limit of quantification value was 0.79 μg/mL. The relative standard deviations (RSDs) of the data of the intra- and inter-day experiments were <1.27% and 0.61%, respectively. The results of the recovery test were 101.35–101.75% with an RSD value of 0.21–1.65%. The developed method was applied successfully to quantify the maltol in three ginseng products manufactured by different methods. Conclusion: The results of validation demonstrated that the proposed HPLC-DAD method was useful for the quantification of maltol in various ginseng products. PMID:26246746

  1. Fast microwave-assisted extraction of rotenone for its quantification in seeds of yam bean (Pachyrhizus sp.).

    PubMed

    Lautié, Emmanuelle; Rasse, Catherine; Rozet, Eric; Mourgues, Claire; Vanhelleputte, Jean-Paul; Quetin-Leclercq, Joëlle

    2013-02-01

    The aim of this study was to find if fast microwave-assisted extraction could be an alternative to the conventional Soxhlet extraction for the quantification of rotenone in yam bean seeds by SPE and HPLC-UV. For this purpose, an experimental design was used to determine the optimal conditions of the microwave extraction. Then the values of the quantification on three accessions from two different species of yam bean seeds were compared using the two different kinds of extraction. A microwave extraction of 11 min at 55°C using methanol/dichloromethane (50:50) allowed rotenone extraction either equivalently or more efficiently than the 8-h-Soxhlet extraction method and was less sensitive to moisture content. The selectivity, precision, trueness, accuracy, and limit of quantification of the method with microwave extraction were also demonstrated. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. 75 FR 22240 - Cyprodinil; Pesticide Tolerances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-28

    ... chromatography with ultraviolet detector (HPLC/UV)) is available to enforce the tolerance expression on plant commodities. In addition, a high performance liquid chromatography with mass spectrometry (HPLC/MS) method...

  3. Determination of the antileukemic drug mitoguazone and seven other closely related bis(amidinohydrazones) in human blood serum by high-performance liquid chromatography.

    PubMed

    Koskinen, M; Elo, H; Lukkari, P; Riekkola, M L

    1996-10-11

    A reversed-phase (C18) HPLC method with diode-array detection was developed for the separation and determination of methylglyoxal bis(amidinohydrazone) (mitoguazone) and seven closely related aliphatic analogs thereof, namely the bis(amidinohydrazones) of glyoxal, dimethylglyoxal, ethylmethylglyoxal, methylpropylglyoxal, butylmethylglyoxal, diethylglyoxal and dipropylglyoxal. The mobile phase consisted of a non-linear binary gradient of methanol and 0.03 M aqueous sodium acetate buffer (pH 4.3). Good separation of the eight congeners was achieved. On increasing the methanol content of the eluent, the bis(amidinohydrazones) eluted in the order of increasing number of carbon atoms in the side-chains. The method was also applied to the quantitative analysis of the compounds in aqueous solution and, combined with ultrafiltration, for the separation of the eight congeners in spiked human blood serum. A separate simplified method for the quantitative determination of each of the compounds in spiked human blood serum samples was also developed. The methods developed made for the first time possible the simultaneous HPLC analysis of more than one bis(amidinohydrazones). The results obtained indicate that the bis(amidinohydrazones) studied obviously have a distinct tendency to form ion associates with acetate ions and probably also other carboxylate ions in aqueous solution. This aspect may be of biochemical significance, especially concerning the intracellular binding of the compounds. Each one of the compounds studied invariably gave rise to one peak only, this result supporting the theory that the conventional synthesis of each of the compounds gives rise to one geometrical isomer only. This result is completely in agreement with the results of previous proton and carbon NMR spectroscopic as well as X-ray diffraction studies.

  4. DETERMINATION OF CHLOROPHEONIS, NITROPHENOIS AND METHYLPHENOIS IN GROUND-WATER SAMPLES USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    EPA Science Inventory

    A high performance liquid chromatography (HPLC) method was developed to quantitatively determine phenolic compounds and their isomers in aqueous samples. The HPLC method can analyze a mixture of 15 contaminants in the same analytical run with an analysis time of 25 minutes. The...

  5. (PRESENT AT NCCU) ANALYSIS OF SELECTED PYRETHROID PESTICIDES USING REVERSE PHASE HIGH LIQUID CHROMATOGRAPHY

    EPA Science Inventory

    This research was conducted in cooperation with EPA Region 4 in Athens, GA to develop a method to analyze selected pyrethroid pesticides using Reverse Phase-High Pressure Liquid Chromatography (HPLC). This HPLC method will aid researchers in separating and identifying these pyre...

  6. A SIMPLE HPLC METHOD FOR DETECTING CARBARYL AND 1-NAPHTHOL IN BIOLOGICAL TISSUES.

    EPA Science Inventory

    Carbamates are a class of pesticide used in both agricultural and residential applications. A simple HPLC method for detecting Carb and its metabolite 1-naphthol (Naph) in tissues was developed to try to correlate tissue levels of carbaryl (Carb) (a prototypical carbamate) with c...

  7. DETERMINATION OF CHLOROPHENOLS, NITROPHENOLS, AND METHYLPHENOLS IN GROUND-WATER SAMPLES USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

    EPA Science Inventory

    A high performance liquid chromatography (HPLC) method was developed to quantitatively determine phenolic compounds and their isomers in aqueous samples. The HPLC method can analyze a mixture of 15 contaminants in the same analytical run with an analysis time of 25 minutes. The...

  8. Comparative study of fourteen alkaloids from Uncaria rhynchophylla hooks and leaves using HPLC-diode array detection-atmospheric pressure chemical ionization/MS method.

    PubMed

    Qu, Jialin; Gong, Tianxing; Ma, Bin; Zhang, Lin; Kano, Yoshihiro; Yuan, Dan

    2012-01-01

    The purpose of the study is to compare alkaloid profile of Uncaria rhynchophylla hooks and leaves. Ten oxindole alkaloids and four glycosidic indole alkaloids were identified using HPLC-diode array detection (DAD) or LC-atmospheric pressure chemical ionization (APCI)-MS method, and a HPLC-UV method for simultaneous quantification of major alkaloids was validated. The hooks are characterized by high levels of four oxindole alkaloids rhynchophylline (R), isorhynchophylline (IR), corynoxeine (C) and isocorynoxeine (IC), while the leaves contained high level of two glycosidic indole alkaloids vincoside lactam (VL) and strictosidine (S). The presented methods have proven its usefulness in chemical characterization of U. rhynchophylla hooks and leaves.

  9. Development and comparison of HPLC-MS/MS and UPLC-MS/MS methods for determining eight coccidiostats in beef.

    PubMed

    Zhao, Xia; Wang, Bo; Xie, Kaizhou; Liu, Jianyu; Zhang, Yangyang; Wang, Yajuan; Guo, Yawen; Zhang, Genxi; Dai, Guojun; Wang, Jinyu

    2018-06-15

    A high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method and an ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for determining eight coccidiostat (halofuginone, lasalocid, maduramicin, monensin, narasin, nigericin, robenidine and salinomycin) residues in beef were developed and compared. Samples were extracted with a mixture of acetic acid, acetonitrile and ethyl acetate and were then purified on a C 18 solid-phase extraction (SPE) column. The purified samples were analyzed by HPLC-MS/MS and UPLC-MS/MS, using 0.1% formic acid-water solution (A) and pure methanol (B) as the mobile phase. The samples were fractionated on a C 18 column using different gradient elution procedures, followed by qualitative analysis using a mass spectrometer operated in multiple reaction monitoring (MRM) mode with positive electrospray ionization; the external standard method was used for quantitation. At spiked levels that ranged from the limit of quantification (LOQ) to 100 μg/kg, the average recoveries were 71.96%-100.32% and 71.24%-89.24%, with relative standard deviations (RSDs) of 2.65%-12.38% and 2.98%-14.86% for UPLC-MS/MS and HPLC-MS/MS, respectively. The limits of detection (LODs) and LOQs of the eight coccidiostats were 0.14-0.32 μg/kg and 0.43-1.21 μg/kg, respectively, for UPLC-MS/MS analysis and 0.16-0.58 μg/kg and 0.53-1.92 μg/kg, respectively, for HPLC-MS/MS analysis. Both methods had good accuracy and precision, but UPLC-MS/MS had higher sensitivity than HPLC-MS/MS. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Analysis of Biomass Sugars Using a Novel HPLC Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agblevor, F. A.; Hames, B. R.; Schell, D.

    The precise quantitative analysis of biomass sugars is a very important step in the conversion of biomass feedstocks to fuels and chemicals. However, the most accurate method of biomass sugar analysis is based on the gas chromatography analysis of derivatized sugars either as alditol acetates or trimethylsilanes. The derivatization method is time consuming but the alternative high-performance liquid chromatography (HPLC) method cannot resolve most sugars found in biomass hydrolysates. We have demonstrated for the first time that by careful manipulation of the HPLC mobile phase, biomass monomeric sugars (arabinose, xylose, fructose, glucose, mannose, and galactose) can be analyzed quantitatively andmore » there is excellent baseline resolution of all the sugars. This method was demonstrated for standard sugars, pretreated corn stover liquid and solid fractions. Our method can also be used to analyze dimeric sugars (cellobiose and sucrose).« less

  11. Efficient IDUA Gene Mutation Detection with Combined Use of dHPLC and Dried Blood Samples

    PubMed Central

    Duarte, Ana Joana; Vieira, Luis

    2013-01-01

    Objectives. Development of a simple mutation directed method in order to allow lowering the cost of mutation testing using an easily obtainable biological material. Assessment of the feasibility of such method was tested using a GC-rich amplicon. Design and Methods. A method of denaturing high-performance liquid chromatography (dHPLC) was improved and implemented as a technique for the detection of variants in exon 9 of the IDUA gene. The optimized method was tested in 500 genomic DNA samples obtained from dried blood spots (DBS). Results. With this dHPLC approach it was possible to detect different variants, including the common p.Trp402Ter mutation in the IDUA gene. The high GC content did not interfere with the resolution and reliability of this technique, and discrimination of G-C transversions was also achieved. Conclusion. This PCR-based dHPLC method is proved to be a rapid, a sensitive, and an excellent option for screening numerous samples obtained from DBS. Furthermore, it resulted in the consistent detection of clearly distinguishable profiles of the common p.Trp402Ter IDUA mutation with an advantageous balance of cost and technical requirements. PMID:27335677

  12. Metabolite fingerprinting of Camptotheca acuminata and the HPLC-ESI-MS/MS analysis of camptothecin and related alkaloids.

    PubMed

    Montoro, Paola; Maldini, Mariateresa; Piacente, Sonia; Macchia, Mario; Pizza, Cosimo

    2010-01-20

    The major phytochemical constituents, namely, alkaloids, flavonoids and ellagic acid derivatives, of leaves of Camptotheca acuminata were identified using high performance liquid chromatography (HPLC) coupled with electrospray mass spectrometry (ESI-MS) in extracts of plants cultivated in Italy and collected at different growth stages. Alkaloids related to camptothecin were identified and quantified by HPLC coupled with ESI-tandem mass spectrometry (MS/MS) employing, respectively, an ion trap and a triple quadrupole mass analyser. The fragmentation patterns of alkaloids related to camptothecin were analysed and a specific Multiple Reaction Monitoring HPLC-MS/MS method was developed for the quantitative determination of these constituents. The described method provides high sensitivity and specificity for the characterisation and quantitative determination of the alkaloids in C. acuminata.

  13. 40 CFR Appendix A to Subpart C of... - Alternative Testing Methods Approved for Analyses Under the Safe Drinking Water Act

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Spectrometry (GC/MS) 525.3 24 Carbofuran High-performance liquid chromatography (HPLC) with post-column... (HPLC) with Post-Column Derivatization and Fluorescence Detection 6651 B 6651 B 6651 B-00, B-05... Chromatography/Mass Spectrometry (GC/MS) 525.3 24 Oxamyl High-performance liquid chromatography (HPLC) with post...

  14. 46 CFR Appendix D to Subpart C of... - Sampling and Analytical Methods for Benzene Monitoring-Measurement Procedures

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... samples are analyzed directly by high performance liquid chromatography (HPLC). Detection limits: 0.01% by... proper selection of HPLC parameters. 2.4. Samples must be free of any particulates that may clog the... clarification kit. 3. Apparatus 3.1. Liquid chromatograph equipped with a UV detector. 3.2. HPLC Column that...

  15. 46 CFR Appendix D to Subpart C of... - Sampling and Analytical Methods for Benzene Monitoring-Measurement Procedures

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... samples are analyzed directly by high performance liquid chromatography (HPLC). Detection limits: 0.01% by... proper selection of HPLC parameters. 2.4. Samples must be free of any particulates that may clog the... clarification kit. 3. Apparatus 3.1. Liquid chromatograph equipped with a UV detector. 3.2. HPLC Column that...

  16. 46 CFR Appendix D to Subpart C of... - Sampling and Analytical Methods for Benzene Monitoring-Measurement Procedures

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... samples are analyzed directly by high performance liquid chromatography (HPLC). Detection limits: 0.01% by... proper selection of HPLC parameters. 2.4. Samples must be free of any particulates that may clog the... clarification kit. 3. Apparatus 3.1. Liquid chromatograph equipped with a UV detector. 3.2. HPLC Column that...

  17. Stability-Indicating Related Substances HPLC Method for Droxidopa and Characterization of Related Substances Using LC-MS and NMR.

    PubMed

    Kumar, Thangarathinam; Ramya, Mohandass; Arockiasamy Xavier, S J

    2016-11-01

    Stress degradation studies using high-performance liquid chromatography (HPLC) was performed and validated for Droxidopa (L-DOPS). Droxidopa was susceptible to acid hydrolysis (0.1 N HCl), alkaline hydrolysis (0.15 N NaOH) and thermal degradation (105°C). It was found to be resistant to white light, oxidation and UV light exposure (72 h). The thermal, acid and alkali degradation impurities were detected with the retention time (RT) of 12.7, 19.25 and 22.95 min. Our HPLC method detected process impurities (2R,3R)-2-amino-3-(3,4-dihydroxyphenyl)-3-hydroxypropionic acid (Impurity H), N-Hydroxypthalimide (Impurity N), (2R,3S)-2-amino-3-(benzo[d][1,3]dioxol-5-yl)-3-hydroxypropionic acid (Impurity L) and L-threo n-phthaloyl-3-(3, 4-dihydroxyphenyl)-serine (Intermediate) with RTs of 3.48, 15.5, 25.76 and 28.0 min. The related substances were further characterized and confirmed by liquid chromatography-mass spectroscopy (LC-MS), and nuclear magnetic resonance spectroscopy analysis. Our HPLC method detected up to 0.05 µg/mL of Droxidopa with S/N > 3.0 and quantified up to 0.10 µg /mL of Droxidopa with S/N ratio > 10.0. Droxidopa was highly stable for 12 h after its preparation for HPLC analysis. Our newly developed HPLC method was highly precise, specific, reliable and accurate for the analysis of Droxidopa and its related substances. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Ion chromatography for the precise analysis of chloride and sodium in sweat for the diagnosis of cystic fibrosis.

    PubMed

    Doorn, J; Storteboom, T T R; Mulder, A M; de Jong, W H A; Rottier, B L; Kema, I P

    2015-07-01

    Measurement of chloride in sweat is an essential part of the diagnostic algorithm for cystic fibrosis. The lack in sensitivity and reproducibility of current methods led us to develop an ion chromatography/high-performance liquid chromatography (IC/HPLC) method, suitable for the analysis of both chloride and sodium in small volumes of sweat. Precision, linearity and limit of detection of an in-house developed IC/HPLC method were established. Method comparison between the newly developed IC/HPLC method and the traditional Chlorocounter was performed, and trueness was determined using Passing Bablok method comparison with external quality assurance material (Royal College of Pathologists of Australasia). Precision and linearity fulfill criteria as established by UK guidelines are comparable with inductively coupled plasma-mass spectrometry methods. Passing Bablok analysis demonstrated excellent correlation between IC/HPLC measurements and external quality assessment target values, for both chloride and sodium. With a limit of quantitation of 0.95 mmol/L, our method is suitable for the analysis of small amounts of sweat and can thus be used in combination with the Macroduct collection system. Although a chromatographic application results in a somewhat more expensive test compared to a Chlorocounter test, more accurate measurements are achieved. In addition, simultaneous measurements of sodium concentrations will result in better detection of false positives, less test repeating and thus faster and more accurate and effective diagnosis. The described IC/HPLC method, therefore, provides a precise, relatively cheap and easy-to-handle application for the analysis of both chloride and sodium in sweat. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  19. High-speed separation and characterization of major constituents in Radix Paeoniae Rubra by fast high-performance liquid chromatography coupled with diode-array detection and time-of-flight mass spectrometry.

    PubMed

    Liu, E-Hu; Qi, Lian-Wen; Li, Bin; Peng, Yong-Bo; Li, Ping; Li, Chang-Yin; Cao, Jun

    2009-01-01

    A fast high-performance liquid chromatography (HPLC) method coupled with diode-array detection (DAD) and electrospray ionization time-of-flight mass spectrometry (ESI-TOFMS) has been developed for rapid separation and sensitive identification of major constituents in Radix Paeoniae Rubra (RPR). The total analysis time on a short column packed with 1.8-microm porous particles was about 20 min without a loss in resolution, six times faster than the performance of a conventional column analysis (115 min). The MS fragmentation behavior and structural characterization of major compounds in RPR were investigated here for the first time. The targets were rapidly screened from RPR matrix using a narrow mass window of 0.01 Da to restructure extracted ion chromatograms. Accurate mass measurements (less than 5 ppm error) for both the deprotonated molecule and characteristic fragment ions represent reliable identification criteria for these compounds in complex matrices with similar if not even better performance compared with tandem mass spectrometry. A total of 26 components were screened and identified in RPR including 11 monoterpene glycosides, 11 galloyl glucoses and 4 other phenolic compounds. From the point of time savings, resolving power, accurate mass measurement capability and full spectral sensitivity, the established fast HPLC/DAD/TOFMS method turns out to be a highly useful technique to identify constituents in complex herbal medicines. (c) 2008 John Wiley & Sons, Ltd.

  20. On-line comprehensive two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography for preparative isolation of Peucedanum praeruptorum.

    PubMed

    Wang, Xin-Yuan; Li, Jia-Fu; Jian, Ya-Mei; Wu, Zhen; Fang, Mei-Juan; Qiu, Ying-Kun

    2015-03-27

    A new on-line comprehensive preparative two-dimensional normal-phase liquid chromatography × reversed-phase liquid chromatography (2D NPLC × RPLC) system was developed for the separation of complicated natural products. It was based on the use of a silica gel packed medium-pressure column as the first dimension and an ODS preparative HPLC column as the second dimension. The two dimensions were connected with normal-phase (NP) and reversed-phase (RP) enrichment units, involving a newly developed airflow assisted adsorption (AAA) technique. The instrument operation and the performance of this NPLC × RPLC separation method were illustrated by gram-scale isolation of ethanol extract from the roots of Peucedanum praeruptorum. In total, 19 compounds with high purity were obtained via automated multi-step preparative separation in a short period of time using this system, and their structures were comprehensively characterized by ESI-MS, (1)H NMR, and (13)C NMR. Including two new compounds, five isomers in two groups with identical HPLC and TLC retention values were also obtained and identified by 1D NMR and 2D NMR. This is the first report of an NPLC × RPLC system successfully applied in an on-line preparative process. This system not only solved the interfacing problem of mobile-phase immiscibility caused by NP and RP separation, it also exhibited apparent advantages in separation efficiency and sample treatment capacity compared with conventional methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Rapid Analysis of Bisphenol A and Its Analogues in Food Packaging Products by Paper Spray Ionization Mass Spectrometry.

    PubMed

    Chen, Shuo; Chang, Quanying; Yin, Kai; He, Qunying; Deng, Yongxiu; Chen, Bo; Liu, Chengbin; Wang, Ying; Wang, Liping

    2017-06-14

    In this study, a paper spray ionization mass spectrometric (PS-MS) method was developed for the rapid in situ screening and simultaneous quantitative analysis of bisphenol A and its analogues, i.e., bisphenol S, bisphenol F, and bisphenol AF, in food packaging products. At the optimal PS-MS conditions, the calibration curves of bisphenols in the range of 1-100 μg/mL were linear. The correlation coefficients were higher than 0.998, and the LODs of the target compounds were 0.1-0.3 μg/mL. After a simple treatment by dichloromethane on the surface, the samples were analyzed by PS-MS in situ for rapid screening without a traditional sample pretreatment procedure, such as powdering, extraction, and enrichment steps. The analytical time of the PS-MS method was less than 1 min. In comparison with conventional HPLC-MS/MS, it was demonstrated that PS-MS was a more effective high-throughput screening and quantitative analysis method.

  2. Secondary metabolites isolation in natural products chemistry: comparison of two semipreparative chromatographic techniques (high pressure liquid chromatography and high performance thin-layer chromatography).

    PubMed

    Do, Thi Kieu Tiên; Hadji-Minaglou, Francis; Antoniotti, Sylvain; Fernandez, Xavier

    2014-01-17

    Chemical investigations on secondary metabolites in natural products chemistry require efficient isolation techniques for characterization purpose as well as for the evaluation of their biological properties. In the case of phytochemical studies, the performance of the techniques is critical (resolution and yield) since the products generally present a narrow range of polarity and physicochemical properties. Several techniques are currently available, but HPLC (preparative and semipreparative) is the most widely used. To compare the performance of semipreparative HPLC and HPTLC for the isolation of secondary metabolites in different types of extracts, we have chosen carvone from spearmint essential oil (Mentha spicata L.), resveratrol from Fallopia multiflora (Thunb.) Haraldson, and rosmarinic acid from rosemary (Rosmarinus officinalis L.) extracts. The comparison was based on the chromatographic separation, the purity and quantity of isolated compounds, the solvent consumption, the duration and the cost of the isolation operations. The results showed that semipreparative HPTLC can in some case offer some advantages over conventional semipreparative HPLC. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Site-specific accumulation and dynamic change of flavonoids in Apocyni Veneti Folium.

    PubMed

    Chen, Cui-Hua; Xu, Hu; Liu, Xun-Hong; Zou, Li-Si; Wang, Mei; Liu, Zi-Xiu; Fu, Xing-Sheng; Zhao, Hui; Yan, Ying

    2017-12-01

    Site-specific accumulation of flavonoids in Apocyni Veneti Folium was determined by laser scanning confocal microscope (LSCM) and the localization of catechins also was observed via vanillin-HCl staining under the conventional optical microscope. The contents of five flavonoids in Apocyni Veneti Folium from different harvest times and growth parts were measured using HPLC method. LSCM observation showed that flavonoids are accumulated in cuticle of epidermal cells and vessel walls, especially in protoplasts and nucleolus of the collenchyma cells and the epidermal cells. Catechins are localized in the palisade parenchyma cells and vessel walls, particularly in the laticifers found in the phloem. On the basis of the difference of the maximal emission wavelength between quercetin and kaempferol derivatives which have fluorescence behavior by appropriate treatment, kaempferol and its derivatives are localized exclusively in the cuticle. Results showed that the content of astragalin in Apocyni Veneti Folium from different parts revealed the decreasing trend, while hyperin and isoquercitrin were higher in June and July analyzed by HPLC. In summary, the site-specific accumulation of flavonoids in Apocyni Veneti Folium can be determined by LSCM and vanillin-HCl staining. The contents of flavonoids in Apocyni Veneti Folium are correlated with harvest times and growth parts. © 2017 Wiley Periodicals, Inc.

  4. Reduction of non-specific adsorption of drugs to plastic containers used in bioassays or analyses.

    PubMed

    Fukazawa, Tominaga; Yamazaki, Yuri; Miyamoto, Yohei

    2010-01-01

    Non-specific adsorption (NSA) of drugs to plastic or glass containers used in clinical use is well known, but methods for reducing NSA have been rarely reported. We assessed the NSA to various containers and then investigated methods to reduce NSA. Probe drugs (methotrexate, warfarin, chloroquine, propranolol, verapamil, digoxin and paclitaxel) dissolved in water were incubated in conventional or low-adsorption containers for 4h at 4 degrees C and the NSA was determined by HPLC. They were also dissolved in aqueous methanol or acetonitrile and the NSA to a conventional polypropylene microplate was determined. Finally, tissue culture microplates were coated with silane coupling agents and the effects of the coatings were evaluated. Hydrophobic drugs (paclitaxel, verapamil and digoxin) were highly adsorbed to conventional plastic microplates, but in addition to hydrophobic drugs, positively charged drugs were well adsorbed to the tissue culture microplate. Low-adsorption microplates could reduce NSA below 15%, but positively charged or neutral hydrophobic drugs showed relatively higher adsorption. Acetonitrile showed stronger NSA inhibition than that of methanol, but the peak shapes of methotrexate and chloroquine were broadened and split. Among the silane coupling agents, GPTMS suppressed the NSA below 10%. Also, AATMS resembled the NSA pattern of GPTMS, but it increased the adsorption of methotrexate to 29%. On conventional plastic microplates, NSA is mainly driven by hydrophobic interactions, but on tissue culture microplates and low-adsorption microplates, in addition to hydrophobic interactions, ionic interactions play a role in the NSA. Therefore, to reduce the NSA to plastic containers, both hydrophobic and ionic interactions should be reduced using amphiphilic organic solvents or neutral and hydrophilic coatings. 2010 Elsevier Inc. All rights reserved.

  5. Determination of biogenic amine profiles in conventional and organic cocoa-based products.

    PubMed

    Restuccia, Donatella; Spizzirri, U Gianfranco; Puoci, Francesco; Picci, Nevio

    2015-01-01

    Cocoa contains many compounds such as biogenic amines (BAs), known to influence consumer health. Spermidine, spermidine, putrescine, histamine, tyramine, β-phenylethylamine, cadaverine and serotonine have been found in several cocoa-based products using HPLC with UV detection after derivatisation with dansyl-chloride. Once optimised in terms of linearity, percentage recovery, LOD, LOQ and repeatability, this method was applied to real samples. Total concentrations of BAs ranged from 5.7 to 79.0 µg g(-)(1) with wide variations depending on the type of sample. BAs present in all samples were in decreasing order: histamine (1.9-38.1 µg g(-)(1)) and tyramine (1.7-31.7 µg g(-)(1)), while putrescine (0.9-32.7 µg g(-)(1)), spermidine (1.0-9.7 µg g(-)(1)) and spermidine (0.6-9.3 µg g(-)(1)) were present in most of the samples. Cadaverine, serotonine and β-phenylethylamine were present in a few samples at much lower concentrations. Organic samples always contained much lower levels of BAs than their conventional counterparts and, generally speaking, the highest amounts of BAs were found in the most processed products.

  6. High-Throughput Screening for a Moderately Halophilic Phenol-Degrading Strain and Its Salt Tolerance Response

    PubMed Central

    Lu, Zhi-Yan; Guo, Xiao-Jue; Li, Hui; Huang, Zhong-Zi; Lin, Kuang-Fei; Liu, Yong-Di

    2015-01-01

    A high-throughput screening system for moderately halophilic phenol-degrading bacteria from various habitats was developed to replace the conventional strain screening owing to its high efficiency. Bacterial enrichments were cultivated in 48 deep well microplates instead of shake flasks or tubes. Measurement of phenol concentrations was performed in 96-well microplates instead of using the conventional spectrophotometric method or high-performance liquid chromatography (HPLC). The high-throughput screening system was used to cultivate forty-three bacterial enrichments and gained a halophilic bacterial community E3 with the best phenol-degrading capability. Halomonas sp. strain 4-5 was isolated from the E3 community. Strain 4-5 was able to degrade more than 94% of the phenol (500 mg·L−1 starting concentration) over a range of 3%–10% NaCl. Additionally, the strain accumulated the compatible solute, ectoine, with increasing salt concentrations. PCR detection of the functional genes suggested that the largest subunit of multicomponent phenol hydroxylase (LmPH) and catechol 1,2-dioxygenase (C12O) were active in the phenol degradation process. PMID:26020478

  7. A simple HPLC method for the comprehensive analysis of cis/trans (Z/E) geometrical isomers of carotenoids for nutritional studies

    USDA-ARS?s Scientific Manuscript database

    Geometrical isomers of carotenoids behave differently in aspects like stability towards oxidants, bioavailability, vitamin A activity and specificity for enzymes. The availability of HPLC methods for their detailed profiling is therefore advisable to expand our knowledge on their metabolism and biol...

  8. Improved method for reliable HMW-GS identification by RP-HPLC and SDS-PAGE in common wheat cultivars

    USDA-ARS?s Scientific Manuscript database

    The accurate identification of alleles for high-molecular weight glutenins (HMW-GS) is critical for wheat breeding programs targeting end-use quality. RP-HPLC methods were optimized for separation of HMW-GS, resulting in enhanced resolution of 1By and 1Dx subunits. Statistically significant differe...

  9. Quality evaluation of Yin Chen Hao Tang extract based on fingerprint chromatogram and simultaneous determination of five bioactive constituents.

    PubMed

    Wang, Xijun; Lv, Haitao; Sun, Hui; Jiang, Xingang; Wu, Zeming; Sun, Wenjun; Wang, Ping; Liu, Lian; Bi, Kaishun

    2008-01-01

    A completely validated method based on HPLC coupled with photodiode array detector (HPLC-UV) was described for evaluating and controlling quality of Yin Chen Hao Tang extract (YCHTE). First, HPLC-UV fingerprint chromatogram of YCHTE was established for preliminarily elucidating amount and chromatographic trajectory of chemical constituents in YCHTE. Second, for the first time, five mainly bioactive constituents in YCHTE were simultaneously determined based on fingerprint chromatogram for furthermore controlling the quality of YCHTE quantitatively. The developed method was applied to analyze 12 batches of YCHTE samples which consisted of herbal drugs from different places of production, showed acceptable linearity, intraday (RSD <5%), interday precision (RSD <4.80%), and accuracy (RSD <2.80%). As a result, fingerprint chromatogram determined 15 representative general fingerprint peaks, and the fingerprint chromatogram resemblances are all better than 0.9996. The contents of five analytes in different batches of YCHTE samples do not indicate significant difference. So, it is concluded that the developed HPLC-UV method is a more fully validated and complete method for evaluating and controlling the quality of YCHTE.

  10. On-line HPLC-DPPH screening method for evaluation of radical scavenging phenols extracted from apples (Malus domestica L.).

    PubMed

    Bandoniene, Donata; Murkovic, Michael

    2002-04-24

    An on-line HPLC-DPPH screening method for phenolic antioxidants in apple methanol/water (80:20, v/v) extracts was applied. The determination of antioxidants was based on a decrease in absorbance at 515 nm after postcolumn reaction of HPLC-separated antioxidants with the 2,2'-diphenyl-1-picrylhydrazyl radicals (DPPH*). Each of the antioxidants separated by the HPLC column was observed as a negative peak corresponding to its antioxidative activity. The on-line method was applied for quantitative analysis of the antioxidants. A linear dependence of negative peak area on concentration of the reference antioxidants was observed. For validation of the on-line method the limit of detection, LOD (microg/mL), and the limit of quantification, LOQ (microg/mL), of the phenolic compounds were determined. Comparison of the UV and DPPH radical quenching chromatograms with authentic compounds identified catechin, chlorogenic acid, caffeic acid, epicatechin, and phloridzin in the apple cultivars (Lobo, Golden Delicious, and Boskoop), and the distribution of total antioxidant activity was calculated.

  11. Cyanobacteria and Cyanotoxins Occurrence and Removal from Five High-Risk Conventional Treatment Drinking Water Plants

    PubMed Central

    Szlag, David C.; Sinclair, James L.; Southwell, Benjamin; Westrick, Judy A.

    2015-01-01

    An environmental protection agency EPA expert workshop prioritized three cyanotoxins, microcystins, anatoxin-a, and cylindrospermopsin (MAC), as being important in freshwaters of the United States. This study evaluated the prevalence of potentially toxin producing cyanobacteria cell numbers relative to the presence and quantity of the MAC toxins in the context of this framework. Total and potential toxin producing cyanobacteria cell counts were conducted on weekly raw and finished water samples from utilities located in five US states. An Enzyme-Linked Immunosorbant Assay (ELISA) was used to screen the raw and finished water samples for microcystins. High-pressure liquid chromatography with a photodiode array detector (HPLC/PDA) verified microcystin concentrations and quantified anatoxin-a and cylindrospermopsin concentrations. Four of the five utilities experienced cyanobacterial blooms in their raw water. Raw water samples from three utilities showed detectable levels of microcystins and a fourth utility had detectable levels of both microcystin and cylindrospermopsin. No utilities had detectable concentrations of anatoxin-a. These conventional plants effectively removed the cyanobacterial cells and all finished water samples showed MAC levels below the detection limit by ELISA and HPLC/PDA. PMID:26075379

  12. Comparative HPLC/ESI-MS and HPLC/DAD study of different populations of cultivated, wild and commercial Gentiana lutea L.

    PubMed

    Mustafa, Ahmed M; Caprioli, Giovanni; Ricciutelli, Massimo; Maggi, Filippo; Marín, Rosa; Vittori, Sauro; Sagratini, Gianni

    2015-05-01

    The root of Gentiana lutea L., famous for its bitter properties, is often used in alcoholic bitter beverages, food products and traditional medicine to stimulate the appetite and improve digestion. This study presents a new, fast, and accurate HPLC method using HPLC/ESI-MS and HPLC/DAD for simultaneous analysis of iridoids (loganic acid), secoiridoids (gentiopicroside, sweroside, swertiamarin, amarogentin) and xanthones (isogentisin) in different populations of G.lutea L., cultivated in the Monti Sibillini National Park, obtained wild there, or purchased commercially. Comparison of HPLC/ESI-MS and HPLC/DAD indicated that HPLC/ESI-MS is more sensitive, reliable and selective. Analysis of twenty samples showed that gentiopicroside is the most dominant compound (1.85-3.97%), followed by loganic acid (0.11-1.30%), isogentisin (0.03-0.48%), sweroside (0.05-0.35%), swertiamarin (0.08-0.30%), and amarogentin (0.01-0.07%). The results confirmed the high quality of the G.lutea cultivated in the Monti Sibillini National Park. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Monitoring and evaluating the quality consistency of Compound Bismuth Aluminate tablets by a simple quantified ratio fingerprint method combined with simultaneous determination of five compounds and correlated with antioxidant activities.

    PubMed

    Liu, Yingchun; Liu, Zhongbo; Sun, Guoxiang; Wang, Yan; Ling, Junhong; Gao, Jiayue; Huang, Jiahao

    2015-01-01

    A combination method of multi-wavelength fingerprinting and multi-component quantification by high performance liquid chromatography (HPLC) coupled with diode array detector (DAD) was developed and validated to monitor and evaluate the quality consistency of herbal medicines (HM) in the classical preparation Compound Bismuth Aluminate tablets (CBAT). The validation results demonstrated that our method met the requirements of fingerprint analysis and quantification analysis with suitable linearity, precision, accuracy, limits of detection (LOD) and limits of quantification (LOQ). In the fingerprint assessments, rather than using conventional qualitative "Similarity" as a criterion, the simple quantified ratio fingerprint method (SQRFM) was recommended, which has an important quantified fingerprint advantage over the "Similarity" approach. SQRFM qualitatively and quantitatively offers the scientific criteria for traditional Chinese medicines (TCM)/HM quality pyramid and warning gate in terms of three parameters. In order to combine the comprehensive characterization of multi-wavelength fingerprints, an integrated fingerprint assessment strategy based on information entropy was set up involving a super-information characteristic digitized parameter of fingerprints, which reveals the total entropy value and absolute information amount about the fingerprints and, thus, offers an excellent method for fingerprint integration. The correlation results between quantified fingerprints and quantitative determination of 5 marker compounds, including glycyrrhizic acid (GLY), liquiritin (LQ), isoliquiritigenin (ILG), isoliquiritin (ILQ) and isoliquiritin apioside (ILA), indicated that multi-component quantification could be replaced by quantified fingerprints. The Fenton reaction was employed to determine the antioxidant activities of CBAT samples in vitro, and they were correlated with HPLC fingerprint components using the partial least squares regression (PLSR) method. In summary, the method of multi-wavelength fingerprints combined with antioxidant activities has been proved to be a feasible and scientific procedure for monitoring and evaluating the quality consistency of CBAT.

  14. Performance characteristics of two bioassays and high-performance liquid chromatography for determination of flucytosine in serum.

    PubMed Central

    St-Germain, G; Lapierre, S; Tessier, D

    1989-01-01

    We compared the accuracy and precision of two microbiological methods and one high-pressure liquid chromatography (HPLC) procedure used to measure the concentrations of flucytosine in serum. On the basis of an analysis of six standards, all methods were judged reliable within acceptable limits for clinical use. With the biological methods, a slight loss of linearity was observed in the 75- to 100-micrograms/ml range. Compared with the bioassays, the HPLC method did not present linearity problems and was more precise and accurate in the critical zone of 100 micrograms/ml. On average, results obtained with patient sera containing 50 to 100 micrograms of flucytosine per ml were 10.6% higher with the HPLC method than with the bioassays. Standards for the biological assays may be prepared in serum or water. PMID:2802566

  15. Development and validation of a new method to simultaneously quantify triazoles in plasma spotted on dry sample spot devices and analysed by HPLC-MS.

    PubMed

    Baietto, Lorena; D'Avolio, Antonio; Marra, Cristina; Simiele, Marco; Cusato, Jessica; Pace, Simone; Ariaudo, Alessandra; De Rosa, Francesco Giuseppe; Di Perri, Giovanni

    2012-11-01

    Therapeutic drug monitoring (TDM) of triazoles is widely used in clinical practice to optimize therapy. TDM is limited by technical problems and cost considerations, such as sample storage and dry-ice shipping. We aimed to develop and validate a new method to analyse itraconazole, posaconazole and voriconazole in plasma spotted on dry sample spot devices (DSSDs) and to quantify them by an HPLC system. Extraction from DSSDs was done using n-hexane/ethyl acetate and ammonia solution. Samples were analysed using HPLC with mass spectrometry (HPLC-MS). Accuracy and precision were assayed by inter- and intra-day validation. The stability of triazoles in plasma spotted on DSSDs was investigated at room temperature for 1 month. The method was compared with a validated standard HPLC method for quantification of triazoles in human plasma. Mean inter- and intra-day accuracy and precision were <15% for all compounds. Triazoles were stable for 2 weeks at room temperature. The method was linear (r(2) > 0.999) in the range 0.031-8 mg/L for itraconazole and posaconazole, and 0.058-15 mg/L for voriconazole. High sensitivity was observed; limits of detection were 0.008, 0.004 and 0.007 mg/L for itraconazole, posaconazole and voriconazole, respectively. A high degree of correlation (r(2) > 0.94) was obtained between the DSSD method and the standard method of analysis. The method that we developed and validated to quantify triazoles in human plasma spotted on DSSDs is accurate and precise. It overcomes problems related to plasma sample storage and shipment, allowing TDM to be performed in a cheaper and safer manner.

  16. Determination of rivaroxaban in patient’s plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS)

    PubMed Central

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels. PMID:28170419

  17. [Spectrophotometric and HPLC evaluation of ceftazidime stability].

    PubMed

    Palade, B; Cioroiu, B; Lazăr, Doina; Corciovă, Andreia; Lazăr, M I

    2010-01-01

    In this paper we followed up the stability of ceftazidime, raw material used in drug industry. Matherials and methods: We used three spectrophotometric methods based on ceftazidime property to form complexes with p-chloranilic acid (ac. p-CA), 3-methylbenzothiazolin-2-on hydrazone (MBTH) and N-(1-naphtil) etilendiamine (NEDA) and a chromatographic method (HPLC). Our results revealed that the substances analyzed maintained minimum content allowable.

  18. [Isolation and purification of seven catechin compounds from fresh tea leaves by semi-preparative liquid chromatography].

    PubMed

    Gong, Zhihong; Chen, Si; Gao, Jiangtao; Li, Meihong; Wang, Xiaxia; Lin, Jun; Yu, Xiaomin

    2017-11-08

    An effective and simple method was established to simultaneously purify seven tea catechins (gallocatechin (GC), epigallocatechin (EGC), catechin (C), epigallocatechin-3- O -gallate (EGCG), epicatechin (EC), epigallocatechin-3- O -(3- O -methyl)-gallate (EGCG3"Me) and epicatechin-3- O -gallate (ECG)) from fresh tea leaves by semi-preparative high performance liquid chromatography (HPLC). Fresh leaves of Tieguanyin tea were successively extracted with methanol and chloroform. Then crude catechins were precipitated from the aqueous fraction of chloroform extraction by adding lead subacetate. Crude catechins were used for the isolation of the seven target catechin compounds by semi-preparative HPLC. Methanol-water and acetonitrile-water were sequentially used as mobile phases. After two rounds of semi-preparative HPLC, all target compounds were achieved with high purities (>90%). The proposed method was tested on two additional tea cultivars and showed similar results. This method demonstrated a simple and efficient strategy based on solvent extraction, ion precipitation and semi-preparative HPLC for the preparation of multiple catechins from tea leaves.

  19. Analysis of the extracts of Isatis tinctoria by new analytical approaches of HPLC, MS and NMR.

    PubMed

    Zhou, Jue; Qu, Fan

    2011-01-01

    The methods of extraction, separation and analysis of alkaloids and indole glucosinolates (GLs) ofIsatis tinctoria were reviewed. Different analytical approaches such as High-pressure Liquid Chromatography (HPLC), Liquid Chromatography with Electrospray Ionization Mass Spectrometry (LC/ESI/MS), Electrospray Ionization Time-Of-Flight Mass Spectrometry (ESI-TOF-MS), and Nuclear Magnetic Resonance (NMR) were used to validate and identity of these constituents. These methods provide rapid separation, identification and quantitative measurements of alkaloids and GLs of Isatis tinctoria. By connection with different detectors to HPLC such as PDA, ELSD, ESI- and APCI-MS in positive and negative ion modes, complicated compounds could be detected with at least two independent detection modes. The molecular formula can be derived in a second step of ESI-TOF-MS data. But for some constituents, UV and MS cannot provide sufficient structure identification. After peak purification, NMR by semi-preparative HPLC can be used as a complementary method.

  20. Direct injection analysis of fatty and resin acids in papermaking process waters by HPLC/MS.

    PubMed

    Valto, Piia; Knuutinen, Juha; Alén, Raimo

    2011-04-01

    A novel HPLC-atmospheric pressure chemical ionization/MS (HPLC-APCI/MS) method was developed for the rapid analysis of selected fatty and resin acids typically present in papermaking process waters. A mixture of palmitic, stearic, oleic, linolenic, and dehydroabietic acids was separated by a commercial HPLC column (a modified stationary C(18) phase) using gradient elution with methanol/0.15% formic acid (pH 2.5) as a mobile phase. The internal standard (myristic acid) method was used to calculate the correlation coefficients and in the quantitation of the results. In the thorough quality parameters measurement, a mixture of these model acids in aqueous media as well as in six different paper machine process waters was quantitatively determined. The measured quality parameters, such as selectivity, linearity, precision, and accuracy, clearly indicated that, compared with traditional gas chromatographic techniques, the simple method developed provided a faster chromatographic analysis with almost real-time monitoring of these acids. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Quantitative determination of flavonoids by column high-performance liquid chromatography with mass spectrometry and ultraviolet absorption detection in Artemisia afra and comparative studies with various species of Artemisia plants.

    PubMed

    Avula, Bharathi; Wang, Yan-Hong; Smillie, Troy J; Mabusela, Wilfred; Vincent, Leszek; Weitz, Frans; Khan, Ikhlas A

    2009-01-01

    A simple and specific analytical method for the quantitative determination of flavonoids from the aerial parts of the Artemisia afra plant samples was developed. By column high-performance liquid chromatography (HPLC) with UV absorption and mass spectrometry (MS) detection, separation was achieved on a reversed-phase octadecylsilyl (C18) column with water, methanol, and acetonitrile, all containing 0.1% acetic acid, as the mobile phase. These methods were used to analyze various species of Artemisia plant samples. The wavelength used for quantification of flavonoids with the diode array detector was 335 nm. The limits of detection (LOD) by HPLC/MS were found to be 7.5, 7.5, 10, 2.0, and 2.0 ng/mL; and by LC-UV the LODs were 500, 500, 500, 300, and 300 ng/mL for apigenin, chrysoeriol, tamarixetin, acacetin, and genkwanin, respectively. The HPLC/MS method was found to be 50-150 times more sensitive than the HPLC-UV method. HPLC/MS coupled with an electrospray ionization interface is described for the identification and quantification of flavonoids in various plant samples. This method involved the use of the [M+H]+ ions of the compounds at mass-to-charge ratio of 1.0606, 301.0712, 317.0661, 285.0763, and 285.0763 (calculated mass), respectively, in the positive ion mode with extractive ion monitoring.

  2. Quantitative and pattern recognition analyses of magnoflorine, spinosin, 6'''-feruloyl spinosin and jujuboside A by HPLC in Zizyphi Semen.

    PubMed

    Kim, Won Il; Zhao, Bing Tian; Zhang, Hai Yan; Lee, Je Hyun; Son, Jong Keun; Woo, Mi Hee

    2014-01-01

    Two rapid and simple HPLC methods with UV detector to determine three main compounds (magnoflorine, spinosin and 6'''-feruloyl spinosin) and evaporative light scattering detector (ELSD) to determine jujuboside A were developed for the chemical analyses of Zizyphi Semen. Magnoflorine, spinosin, and 6'''-feruloyl spinosin were separated with an YMC J'sphere ODS-H80 column (250 mm × 4.6 mm, 4 μm) by the gradient elution followed by the isocratic elution using methanol with 0.1 % formic acid and water with 0.1 % formic acid as the mobile phase. The flow rate was 1.0 mL/min. Jujuboside A was separated by HPLC-ELSD with YoungJinBioChrom Aegispak C18-L column (250 mm × 4.6 mm, 5 μm) column in a gradient elution using methanol with 0.1 % formic acid (A) and water with 0.1 % formic acid as the mobile phase. These two methods were fully validated with respect to linearity, precision, accuracy, stability, and robustness. These HPLC methods were applied successfully to quantify four compounds in a Zizyphi Semen extract. The HPLC analytical methods were validated for pattern recognition analysis by repeated analysis of 91 seed samples corresponding to 48 Zizyphus jujuba var. spinosa (J01-J48) and 43 Zizyphus mauritiana (M01-M43). The results indicate that these methods are suitable for a quality evaluation of Zizyphi Semen.

  3. Quantitative determination of cucurbitane-type triterpenes and triterpene glycosides in dietary supplements containing bitter melon (Momordica charantia) by HPLC-MS/MS.

    PubMed

    Ma, Jun; Krynitsky, Alexander J; Grundel, Erich; Rader, Jeanne I

    2012-01-01

    Momordica charantia L. (Cucurbitaceae), commonly known as bitter melon, is widely cultivated in many tropical and subtropical areas of the world. It is a common food staple; its fruits, leaves, seeds, stems, and roots also have a long history of use in traditional medicine. In the United States, dietary supplements labeled as containing bitter melon can be purchased over-the-counter and from Internet suppliers. Currently, no quantitative analytical method is available for monitoring the content of cucurbitane-type triterpenes and triterpene glycosides, the major constituents of bitter melon, in such supplements. We investigated the use of HPLC-electrospray ionization (ESI)-MS/MS for the quantitative determination of such compounds in dietary supplements containing bitter melon. Values for each compound obtained from external calibration were compared with those obtained from the method of standard additions to address matrix effects associated with ESI. In addition, the cucurbitane-type triterpene and triterpene glycoside contents of two dietary supplements determined by the HPLC-ESI-MS/MS method with standard additions were compared with those measured by an HPLC method with evaporative light scattering detection, which was recently developed for quantification of such compounds in dried fruits of M. charantia. The contents of five cucurbitane-type triterpenes and triterpene glycosides in 10 dietary supplements were measured using the HPLC-ESI-MS/MS method with standard additions. The total contents of the five compounds ranged from 17 to 3464 microg/serving.

  4. Determination of salicylic acid by HPLC in plasma and saliva from children with juvenile chronic arthritis.

    PubMed

    Legaz, M E; Acitores, E; Valverde, F

    1992-12-01

    A high performance liquid chromatography (HPLC) method has been developed for measuring salicylic acid in the plasma and saliva of children with juvenile chronic arthritis (JCA). Samples were extracted with diethyl ether and, after drying, redissolved in methanol to be chromatographed. Quantitation of salicylic acid was performed by reverse phase HPLC on a spherisorb ODS-2 column, using methanol: water: acetic acid as mobile phase. Phenolic was monitored by absorbance at 237 nm. Linearity between the amount of mass injected and the response in the detector was determined. This method was applied to compare concentrations of salivary and plasma salicylic acid. The method also permitted the quantitation of salivary salicylate as a non-invasive, indirect method for monitoring the concentration of plasma salicylate in patients with JCA.

  5. Comparison of high-performance liquid chromatography/tandem mass spectrometry and high-performance liquid chromatography/photo-diode array detection for the quantitation of carotenoids, retinyl esters, α-tocopherol and phylloquinone in chylomicron-rich fractions of human plasma

    PubMed Central

    Kopec, Rachel E.; Schweiggert, Ralf M.; Riedl, Ken M.; Carle, Reinhold; Schwartz, Steven J.

    2013-01-01

    Rationale Bioavailability of essential lipophilic micronutrients and carotenoids is of utmost interest for human health, as the consumption of these compounds may help alleviate major nutritional deficiencies, cardiovascular disease, and cancer. High-performance liquid chromatography/photo-diode array detection (HPLC-PDA) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) were compared for the quantitative analysis of α- and β-carotene, β-cryptoxanthin, lutein, lycopene, α-tocopherol, phylloquinone, and several retinyl esters from chylomicron-containing triglyceride rich lipoprotein (TRL) fractions of human plasma obtained from two clinical trials. Methods After selecting an efficient extraction method for the analytes, both the HPLC/PDA and the HPLC/MS/MS methods were developed and several parameters validated using an HP 1200 series HPLC system interfaced with a HP 1200 series diode-array detector (Agilent Technologies, Santa Clara, CA, USA) and a QTRAP 5500 (AB Sciex, Foster City, CA, USA) via an atmospheric pressure chemical ionization (APCI) probe operated in positive ion mode. Results For lycopene, α- and β-carotene, HPLC/MS/MS was up to 37 times more sensitive than HPLC-PDA. PDA detection was shown to be up to 8 times more sensitive for lutein. MS/MS signals were enhanced by matrix components for lutein and β-cryptoxanthin, as determined by referencing to the matrix-independent PDA signal. In contrast, matrix suppression was observed for retinyl palmitate, α-carotene, and β-carotene. Both detectors showed similar suitability for α-tocopherol, lycopene and retinyl palmitate (representing ~73% of total retinyl esters). MS/MS exclusively allowed the quantitation of minor retinyl esters, phylloquinone, and (Z)-lycopene isomers. Conclusions HPLC/MS/MS was more sensitive than HPLC-PDA for six of the eight analytes and represents a powerful tool for the analysis of chylomicron samples and potentially other biological samples of limited sample size. When internal standards are available for the target carotenoid, employing MS/MS detection may reduce the necessary blood sample volume, which is particularly advantageous for minimizing risk and discomfort to human subjects during clinical studies. PMID:23681818

  6. Determination of isoxaflutole (balance) and its metabolites in water using solid phase extraction followed by high-performance liquid chromatography with ultraviolet or mass spectrometry

    USGS Publications Warehouse

    Lin, Chung-Ho; Lerch, Robert N.; Thurman, E. Michael; Garrett , Harold E.; George, Milon F.

    2002-01-01

    Balance (isoxaflutole, IXF) belongs to a new family of herbicides referred to as isoxazoles. IXF has a very short soil half-life (<24 h), degrading to a biologically active diketonitrile (DKN) metabolite that is more polar and considerably more stable. Further degradation of the DKN metabolite produces a nonbiologically active benzoic acid (BA) metabolite. Analytical methods using solid phase extraction followed by high-performance liquid chromatography−UV (HPLC-UV) or high-performance liquid chromatography−mass spectrometry (HPLC-MS) were developed for the analysis of IXF and its metabolites in distilled deionized water and ground water samples. To successfully detect and quantify the BA metabolite by HPLC-UV from ground water samples, a sequential elution scheme was necessary. Using HPLC-UV, the mean recoveries from sequential elution of the parent and its two metabolites from fortified ground water samples ranged from 68.6 to 101.4%. For HPLC-MS, solid phase extraction of ground water samples was performed using a polystyrene divinylbenzene polymer resin. The mean HPLC-MS recoveries of the three compounds from ground water samples spiked at 0.05−2 μg/L ranged from 100.9 to 110.3%. The limits of quantitation for HPLC-UV are approximately 150 ng/L for IXF, 100 ng/L for DKN, and 250 ng/L for BA. The limit of quantitation by HPLC-MS is 50 ng/L for each compound. The methods developed in this work can be applied to determine the transport and fate of Balance in the environment.

  7. Determination of isoxaflutole (balance) and its metabolites in water using solid phase extraction followed by high-performance liquid chromatography with ultraviolet or mass spectrometry.

    PubMed

    Lin, Chung-Ho; Lerch, Robert N; Thurman, E Michael; Garrett, Harold E; George, Milon F

    2002-10-09

    Balance (isoxaflutole, IXF) belongs to a new family of herbicides referred to as isoxazoles. IXF has a very short soil half-life (<24 h), degrading to a biologically active diketonitrile (DKN) metabolite that is more polar and considerably more stable. Further degradation of the DKN metabolite produces a nonbiologically active benzoic acid (BA) metabolite. Analytical methods using solid phase extraction followed by high-performance liquid chromatography-UV (HPLC-UV) or high-performance liquid chromatography-mass spectrometry (HPLC-MS) were developed for the analysis of IXF and its metabolites in distilled deionized water and ground water samples. To successfully detect and quantify the BA metabolite by HPLC-UV from ground water samples, a sequential elution scheme was necessary. Using HPLC-UV, the mean recoveries from sequential elution of the parent and its two metabolites from fortified ground water samples ranged from 68.6 to 101.4%. For HPLC-MS, solid phase extraction of ground water samples was performed using a polystyrene divinylbenzene polymer resin. The mean HPLC-MS recoveries of the three compounds from ground water samples spiked at 0.05-2 microg/L ranged from 100.9 to 110.3%. The limits of quantitation for HPLC-UV are approximately 150 ng/L for IXF, 100 ng/L for DKN, and 250 ng/L for BA. The limit of quantitation by HPLC-MS is 50 ng/L for each compound. The methods developed in this work can be applied to determine the transport and fate of Balance in the environment.

  8. Simultaneous analysis of 17 diuretics in dietary supplements by HPLC and LC-MS/MS.

    PubMed

    Woo, H; Kim, J W; Han, K M; Lee, J H; Hwang, I S; Lee, J H; Kim, J; Kweon, S J; Cho, S; Chae, K R; Han, S Y; Kim, J

    2013-01-01

    In order to test health foods for illegally added diuretics for weight loss, we developed simple, rapid, selective, and sensitive methods using HPLC and LC-MS/MS for the simultaneous analysis of 17 diuretics in dietary supplements. HPLC conditions were set with a Capcell-pak C18, using a mobile phase consisting of gradient conditions, UV detection at 254 nm and validated for linearity (r(2)> 0.999), precision (CV ≤ 3%), recoveries (90.4-102.8%) and reproducibility. Identification and quantification of 17 diuretics were accomplished by ion-spray LC-MS/MS using multiple reaction monitoring (MRM). The chromatographic separation was carried out under the reversed-phase mechanism on an HSS-T3 column. The LC-MS/MS method was validated for linearity (r(2)> 0.99) and precision (CV < 13%). Sixteen dietary supplements were tested with the developed methods. Diuretics were not detected in all samples. Extraction recovery was also investigated and the extraction recoveries in different formulations were from 88% to 110% and from 81% to 116% using HPLC and LC-MS/MS, respectively. There was no significant difference in recoveries in the type of dietary supplements. Based on this result, the developed methods to monitor illegal drug adulterations in dietary supplements using HPLC and LC-MS/MS are simple, fast and reliable. Therefore, it is applicable to routine drug-adulteration screening.

  9. Detection of β-Lactams and Chloramphenicol Residues in Raw Milk-Development and Application of an HPLC-DAD Method in Comparison with Microbial Inhibition Assays.

    PubMed

    Karageorgou, Eftychia; Christoforidou, Sofia; Ioannidou, Maria; Psomas, Evdoxios; Samouris, Georgios

    2018-06-01

    The present study was carried out to assess the detection sensitivity of four microbial inhibition assays (MIAs) in comparison with the results obtained by the High Performance Liquid Chromatography with Diode-Array Detection (HPLC-DAD) method for antibiotics of the β-lactam group and chloramphenicol in fortified raw milk samples. MIAs presented fairly good results when detecting β-lactams, whereas none were able to detect chloramphenicol at or above the permissible limits. HPLC analysis revealed high recoveries of examined compounds, whereas all detection limits observed were lower than their respective maximum residue limits (MRL) values. The extraction and clean-up procedure of antibiotics was performed by a modified matrix solid phase dispersion procedure using a mixture of Plexa by Agilent and QuEChERS as a sorbent. The HPLC method developed was validated, determining the accuracy, precision, linearity, decision limit, and detection capability. Both methods were used to monitor raw milk samples of several cows and sheep, obtained from producers in different regions of Greece, for the presence of examined antibiotic residues. Results obtained showed that MIAs could be used effectively and routinely to detect antibiotic residues in several milk types. However, in some cases, spoilage of milk samples revealed that the kits' sensitivity could be strongly affected, whereas this fact does not affect the effectiveness of HPLC-DAD analysis.

  10. HPLC and LC-MS/MS methods for determination of sodium benzoate and potassium sorbate in food and beverages: performances of local accredited laboratories via proficiency tests in Turkey.

    PubMed

    Gören, Ahmet C; Bilsel, Gökhan; Şimşek, Adnan; Bilsel, Mine; Akçadağ, Fatma; Topal, Kevser; Ozgen, Hasan

    2015-05-15

    High Performance Liquid Chromatography LC-UV and LC-MS/MS methods were developed and validated for quantitative analyses of sodium benzoate and potassium sorbate in foods and beverages. HPLC-UV and LC-MS/MS methods were compared for quantitative analyses of sodium benzoate and potassium sorbate in a representative ketchup sample. Optimisation of the methods enabled the chromatographic separation of the analytes in less than 4 min. A correlation coefficient of 0.999 was achieved over the measured calibration range for both compounds and methods (HPLC and LC-MS/MS). The uncertainty values of sodium benzoate and potassium sorbate were found as 0.199 and 0.150 mg/L by HPLC and 0.072 and 0.044 mg/L by LC-MS/MS, respectively. Proficiency testing performance of Turkish accredited laboratories between the years 2005 and 2013 was evaluated and reported herein. The aim of the proficiency testing scheme was to evaluate the performance of the laboratories, analysing benzoate and sorbate in tomato ketchup. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Quantification of appetite suppressing steroid glycosides from Hoodia gordonii in dried plant material, purified extracts and food products using HPLC-UV and HPLC-MS methods.

    PubMed

    Janssen, Hans-Gerd; Swindells, Chris; Gunning, Philip; Wang, Weijun; Grün, Christian; Mahabir, Krishna; Maharaj, Vinesh J; Apps, Peter J

    2008-06-09

    High-performance liquid chromatography (HPLC)-UV and HPLC-Mass Spectrometry (MS) methods were developed for the quantitative analysis of the family of Hoodia gordonii steroid glycosides with appetite suppressing properties in dried plant material, in purified and enriched extracts and in various prototype food-products fortified with H. gordonii extracts. For solid materials, e.g. dried plants or for non-fatty foods, extraction of the steroid glycosides is performed using methanol. For products where the steroid glycosides are present in an oil matrix, direct injection of the oil after dilution in tetrahydrofuran is applied. The HPLC separation is performed on an octyl-modified reversed-phase column in the gradient mode with UV detection at lambda = 220 nm. Quantification is performed against an external calibration line prepared using either one of the pure steroid glycosides or geranyl-tiglate. Short- and long-term repeatabilities of the methods are better than 3 and 6%, respectively. Recoveries are better than 85%, even in the analysis of the least abundant steroid glycosides in a complex yoghurt drink. Linearity is better than 3-4 orders of magnitude and the detection limits are below approximately 2 microg g(-1) for the individual steroid glycosides in dried plant material and food products. HPLC-MS is used to confirm that the steroid glycosides contain the characteristic steroid core, the carbohydrate chain and the tigloyl group.

  12. Dispersion of C(60) in natural water and removal by conventional drinking water treatment processes.

    PubMed

    Hyung, Hoon; Kim, Jae-Hong

    2009-05-01

    The first objective of this study is to examine the fate of C(60) under two disposal scenarios through which pristine C(60) is introduced to water containing natural organic matter (NOM). A method based on liquid-liquid extraction and HPLC to quantify nC(60) in water containing NOM was also developed. When pristine C(60) was added to water either in the form of dry C(60) or in organic solvent, it formed water stable aggregates with characteristics similar to nC(60) prepared by other methods reported in the literature. The second objective of this study is to examine the fate of the nC(60) in water treatment processes, which are the first line of defense against ingestion from potable water -- a potential route for direct human consumption. Results obtained from jar tests suggested that these colloidal aggregates of C(60) were efficiently removed by a series of alum coagulation, flocculation, sedimentation and filtration processes, while the efficiency of removal dependent on various parameters such as pH, alkalinity, NOM contents and coagulant dosage. Colloidal aggregates of functionalized C(60) could be well removed by the conventional water treatment processes but with lesser efficiency compared to those made of pristine C(60).

  13. Evaluation of spectrophotometric and HPLC methods for shikimic acid determination in plants: models in glyphosate-resistant and -susceptible crops.

    PubMed

    Zelaya, Ian A; Anderson, Jennifer A H; Owen, Micheal D K; Landes, Reid D

    2011-03-23

    Endogenous shikimic acid determinations are routinely used to assess the efficacy of glyphosate in plants. Numerous analytical methods exist in the public domain for the detection of shikimic acid, yet the most commonly cited comprise spectrophotometric and high-pressure liquid chromatography (HPLC) methods. This paper compares an HPLC and two spectrophotometric methods (Spec 1 and Spec 2) and assesses the effectiveness in the detection of shikimic acid in the tissues of glyphosate-treated plants. Furthermore, the study evaluates the versatility of two acid-based shikimic acid extraction methods and assesses the longevity of plant extract samples under different storage conditions. Finally, Spec 1 and Spec 2 are further characterized with respect to (1) the capacity to discern between shikimic acid and chemically related alicyclic hydroxy acids, (2) the stability of the chromophore (t1/2), (3) the detection limits, and (4) the cost and simplicity of undertaking the analytical procedure. Overall, spectrophotometric methods were more cost-effective and simpler to execute yet provided a narrower detection limit compared to HPLC. All three methods were specific to shikimic acid and detected the compound in the tissues of glyphosate-susceptible crops, increasing exponentially in concentration within 24 h of glyphosate application and plateauing at approximately 72 h. Spec 1 estimated more shikimic acid in identical plant extract samples compared to Spec 2 and, likewise, HPLC detection was more effective than spectrophotometric determinations. Given the unprecedented global adoption of glyphosate-resistant crops and concomitant use of glyphosate, an effective and accurate assessment of glyphosate efficacy is important. Endogenous shikimic acid determinations are instrumental in corroborating the efficacy of glyphosate and therefore have numerous applications in herbicide research and related areas of science as well as resolving many commercial issues as a consequence of glyphosate utilization.

  14. Analytical methods for determination of alkaloids and saponins from roots of Caulophyllum thalictroids (L) Michx using UPLC HPLC and HPTLC

    USDA-ARS?s Scientific Manuscript database

    A comparison study of analytical methods including HPLC, UPLC and HPTLC are presented in this paper for the determination of major alkaloid and triterpene saponins from the roots of Caulophyllum thalictroides (L.) Michx. (blue cohosh) and dietary supplements claiming to contain blue cohosh. The meth...

  15. An industry consensus study on an HPLC fluorescence method for the determination of (±)-catechin and (±)-epicatechin in cocoa and chocolate products.

    PubMed

    Shumow, Laura; Bodor, Alison

    2011-07-05

    This manuscript describes the results of an HPLC study for the determination of the flavan-3-ol monomers, (±)-catechin and (±)-epicatechin, in cocoa and plain dark and milk chocolate products. The study was performed under the auspices of the National Confectioners Association (NCA) and involved the analysis of a series of samples by laboratories of five member companies using a common method. The method reported in this paper uses reversed phase HPLC with fluorescence detection to analyze (±)-epicatechin and (±)-catechin extracted with an acidic solvent from defatted cocoa and chocolate. In addition to a variety of cocoa and chocolate products, the sample set included a blind duplicate used to assess method reproducibility. All data were subjected to statistical analysis with outliers eliminated from the data set. The percent coefficient of variation (%CV) of the sample set ranged from approximately 7 to 15%. Further experimental details are described in the body of the manuscript and the results indicate the method is suitable for the determination of (±)-catechin and (±)-epicatechin in cocoa and chocolate products and represents the first collaborative study of this HPLC method for these compounds in these matrices.

  16. Comparison of high-performance liquid chromatography and supercritical fluid chromatography using evaporative light scattering detection for the determination of plasticizers in medical devices.

    PubMed

    Lecoeur, Marie; Decaudin, Bertrand; Guillotin, Yoann; Sautou, Valérie; Vaccher, Claude

    2015-10-23

    Recently, interest in supercritical fluid chromatography (SFC) has increased due to its high throughput and the development of new system improving chromatographic performances. However, most papers dealt with fundamental studies and chiral applications and only few works described validation process of SFC method. Likewise, evaporative light scattering detection (ELSD) has been widely employed in liquid chromatography but only a few recent works presented its quantitative performances hyphenated with SFC apparatus. The present paper discusses about the quantitative performances of SFC-ELSD compared to HPLC-ELSD, for the determination of plasticizers (ATBC, DEHA, DEHT and TOTM) in PVC tubing used as medical devices. After the development of HPLC-ELSD, both methods were evaluated based on the total error approach using accuracy profile. The results show that HPLC-ELSD was more precise than SFC-ELSD but lower limits of quantitation were obtained by SFC. Hence, HPLC was validated in the ± 10% acceptance limits whereas SFC lacks of accuracy to quantify plasticizers. Finally, both methods were used to determine the composition of plasticized-PVC medical devices. Results demonstrated that SFC and HPLC both hyphenated with ELSD provided similar results. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Fingerprint chromatogram analysis of Pseudostellaria heterophylla (Miq.) Pax root by high performance liquid chromatography.

    PubMed

    Han, Chao; Chen, Junhui; Chen, Bo; Lee, Frank Sen-Chun; Wang, Xiaoru

    2006-09-01

    A simple and reliable high performance liquid chromatographic (HPLC) method has been developed and validated for the fingerprinting of extracts from the root of Pseudostellaria heterophylla (Miq.) Pax. HPLC with gradient elution was performed on an authentic reference standard of powdered P. heterophylla (Miq.) Pax root and 11 plant samples of the root were collected from different geographic locations. The HPLC chromatograms have been standardized through the selection and identification of reference peaks and the normalization of retention times and peak intensities of all the common peaks. The standardized HPLC fingerprints show high stability and reproducibility, and thus can be used effectively for the screening analysis or quality assessment of the root or its derived products. Similarity index calculations based on cosine angle values or correlation methods have been performed on the HPLC fingerprints. As a group, the fingerprints of the P. heterophylla (Miq.) Pax samples studied are highly correlated with closely similar fingerprints. Within the group, the samples can be further divided into subgroups based on hierarchical clustering analysis (HCA). Sample grouping based on HCA coincides nicely with those based on the geographical origins of the samples. The HPLC fingerprinting techniques thus have high potential in authentication or source-tracing types of applications.

  18. Determination of trace amounts of rare-earth elements in highly pure neodymium oxide by sector field inductively coupled plasma mass spectrometry (ICP-SFMS) and high-performance liquid chromatography (HPLC) techniques

    NASA Astrophysics Data System (ADS)

    Pedreira, W. R.; Sarkis, J. E. S.; da Silva Queiroz, C. A.; Rodrigues, C.; Tomiyoshi, I. A.; Abrão, A.

    2003-02-01

    Recently rare-earth elements (REE) have received much attention in fields of geochemistry and industry. Rapid and accurate determinations of them are increasingly required as industrial demands expand. Sector field inductively coupled plasma mass spectrometry (ICP-SFMS) with high-performance liquid chromatography (HPLC) has been applied to the determination of REE. HR ICP-MS was used as an element-selective detector for HPLC in highly pure materials. The separation of REE with HPLC helped to avoid erroneous analytical results due to spectral interferences. Sixteen elements (Sc, Y and 14 lanthanides) were determined selectively with the HPLC/ICP-SFMS system using a concentration gradient methods. The detection limits with the HPLC/ICP-SFMS system were about 0.5-10 pg mL-1. The percentage recovery ranged from 90% to 100% for different REE. The %RSD of the methods varying between 2.5% and 4.5% for a set of five (n=5) replicates was found for the IPEN's material and for the certificate reference sample. Determination of trace REEs in two highly pure neodymium oxides samples (IPEN and Johnson Matthey Company) were performed. In short, the IPEN's materials which are highly pure (>99.9%) were successfully analyzed without spectral interferences.

  19. Characterization and quantification of flavonoids and saponins in adzuki bean (Vigna angularis L.) by HPLC-DAD-ESI-MSn analysis.

    PubMed

    Liu, Rui; Cai, Zongwei; Xu, Baojun

    2017-09-22

    Bioactive activities of adzuki bean have been widely reported, however, the phytochemical information of adzuki bean is incomplete. The aim of this study was to characterize and quantify flavonoids and saponins in adzuki bean. High performance liquid chromatography with diode array detection and electro spray ionization-tandem multi-stage mass spectrometry (HPLC-DAD-ESI-MS n ) were applied to do qualitative and quantitative analyses. A total of 15 compounds from adzuki bean were identified by HPLC-DAD-ESI-MS n . Among 15 compounds identified, four flavonoids (catechin, vitexin-4″-O-glucoside, quercetin-3-O-glucoside, and quercetin-3-O-rutinoside) and six saponins (azukisaponin I, II, III, IV, V, and VI) in adzuki bean were further quantified by external calibration method using HPLC-MS with the program of time segment and extract ion chromatogram (EIC) analysis. Current qualitative and quantitative method based on HPLC and MS technique provides a scientific basis for in vitro and in vivo pharmacological study in the future. Graphical abstract Isolation and characterization of flavonoids and saponins from adzuki bean.

  20. A simplified guide for charged aerosol detection of non-chromophoric compounds-Analytical method development and validation for the HPLC assay of aerosol particle size distribution for amikacin.

    PubMed

    Soliven, Arianne; Haidar Ahmad, Imad A; Tam, James; Kadrichu, Nani; Challoner, Pete; Markovich, Robert; Blasko, Andrei

    2017-09-05

    Amikacin, an aminoglycoside antibiotic lacking a UV chromophore, was developed into a drug product for delivery by inhalation. A robust method for amikacin assay analysis and aerosol particle size distribution (aPSD) determination, with comparable performance to the conventional UV detector was developed using a charged aerosol detector (CAD). The CAD approach involved more parameters for optimization than UV detection due to its sensitivity to trace impurities, non-linear response and narrow dynamic range of signal versus concentration. Through careful selection of the power transformation function value and evaporation temperature, a wider linear dynamic range, improved signal-to-noise ratio and high repeatability were obtained. The influences of mobile phase grade and glassware binding of amikacin during sample preparation were addressed. A weighed (1/X 2 ) least square regression was used for the calibration curve. The limit of quantitation (LOQ) and limit of detection (LOD) for this method were determined to be 5μg/mL and 2μg/mL, respectively. The method was validated over a concentration range of 0.05-2mg/mL. The correlation coefficient for the peak area versus concentration was 1.00 and the y-intercept was 0.2%. The recovery accuracies of triplicate preparations at 0.05, 1.0, and 2.0mg/mL were in the range of 100-101%. The relative standard deviation (S rel ) of six replicates at 1.0mg/mL was 1%, and S rel of five injections at the limit of quantitation was 4%. A robust HPLC-CAD method was developed and validated for the determination of the aPSD for amikacin. The CAD method development produced a simplified procedure with minimal variability in results during: routine operation, transfer from one instrument to another, and between different analysts. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Removal of diclofenac by conventional drinking water treatment processes and granular activated carbon filtration.

    PubMed

    Rigobello, Eliane Sloboda; Dantas, Angela Di Bernardo; Di Bernardo, Luiz; Vieira, Eny Maria

    2013-06-01

    This study was carried out to evaluate the efficiency of conventional drinking water treatment processes with and without pre-oxidation with chlorine and chlorine dioxide and the use of granular activated carbon (GAC) filtration for the removal of diclofenac (DCF). Water treatment was performed using the Jar test with filters on a lab scale, employing nonchlorinated artesian well water prepared with aquatic humic substances to yield 20HU true color, kaolin turbidity of 70 NTU and 1mgL(-1) DCF. For the quantification of DCF in water samples, solid phase extraction and HPLC-DAD methods were developed and validated. There was no removal of DCF in coagulation with aluminum sulfate (3.47mgAlL(-1) and pH=6.5), flocculation, sedimentation and sand filtration. In the treatment with pre-oxidation and disinfection, DCF was partially removed, but the concentration of dissolved organic carbon (DOC) was unchanged and byproducts of DCF were observed. Chlorine dioxide was more effective than chorine in oxidizing DCF. In conclusion, the identification of DCF and DOC in finished water indicated the incomplete elimination of DCF through conventional treatments. Nevertheless, conventional drinking water treatment followed by GAC filtration was effective in removing DCF (⩾99.7%). In the oxidation with chlorine, three byproducts were tentatively identified, corresponding to a hydroxylation, aromatic substitution of one hydrogen by chlorine and a decarboxylation/hydroxylation. Oxidation with chlorine dioxide resulted in only one byproduct (hydroxylation). Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Preparation and analysis of standardized waste samples for Controlled Ecological Life Support Systems (CELSS)

    NASA Technical Reports Server (NTRS)

    Carden, J. L.; Browner, R.

    1982-01-01

    The preparation and analysis of standardized waste samples for controlled ecological life support systems (CELSS) are considered. Analysis of samples from wet oxidation experiments, the development of ion chromatographic techniques utilizing conventional high pressure liquid chromatography (HPLC) equipment, and an investigation of techniques for interfacing an ion chromatograph (IC) with an inductively coupled plasma optical emission spectrometer (ICPOES) are discussed.

  3. Determination of intracellular glutathione and cysteine using HPLC with a monolithic column after derivatization with monobromobimane.

    PubMed

    Conlan, Xavier A; Stupka, Nicole; McDermott, Geoffrey P; Francis, Paul S; Barnett, Neil W

    2010-05-01

    An optimized high-performance liquid chromatography (HPLC) method is used to show that, as myoblasts differentiate into multinucleated muscle fibers, there is a shift to a more oxidized cell redox state. The HPLC method incorporated derivatization with monobromobimane for the determination of the reduced (GSH) and oxidized (GSSG) forms of glutathione and the reduced (Cys) and oxidized (CysSS) forms of cysteine. The derivatization was optimized to improve the sensitivity of the approach; the limits of detection for glutathione and cysteine were 3 x 10(-8) and 5 x 10(-8) M, respectively. 2009 John Wiley & Sons, Ltd.

  4. Quantification of astaxanthin in shrimp waste hydrolysate by HPLC.

    PubMed

    López-Cervantes, J; Sánchez-Machado, D I; Gutiérrez-Coronado, M A; Ríos-Vázquez, N J

    2006-10-01

    In the present study, a simple and rapid reversed-phase HPLC method for the determination of astaxanthin in shrimp waste hydrolysate has been developed and validated. The analytical procedure involves the direct extraction of astaxanthin from the lipid fraction with methanol. The analytical column, SS Exil ODS, was operated at 25C. The mobile phase consisted of a mixture of water:methanol:dichloromethane:acetonitrile (4.5:28:22:45.5 v/v/v/v) at a flow rate of 1.0 mL/min. Detection and identification were performed using a photodiode array detector (lambda(detection) = 476 nm). The proposed HPLC method showed adequate linearity, repeatability and accuracy.

  5. Pharmacokinetic study of arctigenin in rat plasma and organ tissue by RP-HPLC method.

    PubMed

    He, Fan; Dou, De-Qiang; Hou, Qiang; Sun, Yu; Kang, Ting-Guo

    2013-01-01

    A high-performance liquid chromatography (HPLC) technique was developed for the determination of arctigenin in plasma and various organs of rats after the oral administration of 30, 50 and 70 mgkg(-1) of arctigenin to the Sprague-Dawley rats. Results showed that the validated HPLC method was simple, fast, reproducible and suitable to the determination of arctigenin in rat plasma and organ tissue and one-compartmental model with zero-order absorption process can well describe the changes of arctigenin concentration in the plasma. The concentration of compound was highest in the spleen, less in the liver and the least in the lung.

  6. Short communication: separation and quantification of caseins and casein macropeptide using ion-exchange chromatography.

    PubMed

    Holland, B; Rahimi Yazdi, S; Ion Titapiccolo, G; Corredig, M

    2010-03-01

    The aim of this work was to improve an existing method to separate and quantify the 4 major caseins from milk samples (i.e., containing whey proteins) using ion-exchange chromatography. The separation process was carried out using a mini-preparative cation exchange column (1 or 5mL of column volume), using urea acetate as elution buffer at pH 3.5 with a NaCl gradient. All 4 major caseins were separated, and the purity of each peak was assessed using sodium dodecyl sulfate-PAGE. Purified casein fractions were also added to raw milk to confirm their elution volumes. The quantification was carried out using purified caseins in buffer as well as added directly to fresh skim milk. This method can also be employed to determine the decrease in kappa-casein and the release of the casein-macropeptide during enzymatic hydrolysis using rennet. In this case, the main advantage of using this method is the lack of organic solvents compared with the conventional method for separation of macropeptide (using reversed phase HPLC).

  7. Analysis of microdialysate monoamines, including noradrenaline, dopamine and serotonin, using capillary ultra-high performance liquid chromatography and electrochemical detection.

    PubMed

    Ferry, Barbara; Gifu, Elena-Patricia; Sandu, Ioana; Denoroy, Luc; Parrot, Sandrine

    2014-03-01

    Electrochemical methods are very often used to detect catecholamine and indolamine neurotransmitters separated by conventional reverse-phase high performance liquid chromatography (HPLC). The present paper presents the development of a chromatographic method to detect monoamines present in low-volume brain dialysis samples using a capillary column filled with sub-2μm particles. Several parameters (repeatability, linearity, accuracy, limit of detection) for this new ultrahigh performance liquid chromatography (UHPLC) method with electrochemical detection were examined after optimization of the analytical conditions. Noradrenaline, adrenaline, serotonin, dopamine and its metabolite 3-methoxytyramine were separated in 1μL of injected sample volume; they were detected above concentrations of 0.5-1nmol/L, with 2.1-9.5% accuracy and intra-assay repeatability equal to or less than 6%. The final method was applied to very low volume dialysates from rat brain containing monoamine traces. The study demonstrates that capillary UHPLC with electrochemical detection is suitable for monitoring dialysate monoamines collected at high sampling rate. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Matrix-assisted laser-desorption/ionization mass spectrometric imaging of olanzapine in a single hair using esculetin as a matrix.

    PubMed

    Wang, Hang; Wang, Ying; Wang, Ge; Hong, Lizhi

    2017-07-15

    Matrix-assisted laser desorption/ionization-mass spectrometric imaging (MALDI-MSI) for the analysis of intact hair is a powerful tool for monitoring changes in drug consumption. The embedding of a low drug concentration in the hydrophobic hair matrix makes it difficult to extract and detect, and requires an improved method to increase detection sensitivity. In this study, an MSI method using MALDI-Fourier transform ion cyclotron resonance was developed for direct identification and imaging of olanzapine in hair samples using the positive ion mode. Following decontamination, scalp hair samples from an olanzapine user were scraped from the proximal to the distal end three times, and 5mm hair sections were fixed onto an Indium-Tin-Oxide (ITO)-coated microscopic glass slide. Esculetin (6,7-dihydroxy-2H-chromen-2-one) was used as a new hydrophobic matrix to increase the affinity, extraction and ionization efficiency of olanzapine in the hair samples. The spatial distribution of olanzapine was observed using five single hairs from the same drug user. This matrix improves the affinity of olanzapine in hair for molecular imaging with mass spectrometry. This method may provide a detection power for olanzapine to the nanogram level per 5mm hair. Time course changes in the MSI results were also compared with quantitative HPLC-MS/MS for each 5mm segment of single hair shafts selected from the MALDI target. MALDI imaging intensities in single hairs showed good semi-quantitative correlation with the results from conventional HPLC-MS/MS. MALDI-MSI is suitable for monitoring drug intake with a high time resolution. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Greek PDO saffron authentication studies using species specific molecular markers.

    PubMed

    Bosmali, I; Ordoudi, S A; Tsimidou, M Z; Madesis, P

    2017-10-01

    Saffron, the spice produced from the red stigmas of the flower of Crocus sativus L. is a frequent target of fraud and mislabeling practices that cannot be fully traced using the ISO 3632 trade standard specifications and test methods. A molecular approach is proposed herein as a promising branding strategy for the authentication of highly esteemed saffron brands such as the Greek Protected Designation of Origin (PDO) "Krokos Kozanis". Specific ISSR (inter-simple sequence repeat) markers were used to assess for the first time, the within species variability of several populations of C. sativus L. from the cultivation area of "Krokos Kozanis" as well as the potential differences with the band pattern produced by other Crocus species. Then, species-specific markers were developed taking advantage of an advanced molecular technique such as the HRM analysis coupled with universal DNA barcoding regions (trnL) (Bar-HRM) and applied to saffron admixtures with some of the most common plant adulterants (Calendula officinalis, Carthamus tinctorius, Gardenia jasminoides, Zea mays and Curcuma longa). The sensitivity of the procedure was tested for turmeric as a case study whereas HPLC-fluorescence determination of secondary metabolites was also employed for comparison. The overall results indicated that the Bar-HRM approach is quite effective in terms of specificity and sensitivity. Its effectiveness regarding the detection of turmeric was comparable to that of a conventional HPLC method (0.5% vs 1.0%, w/w). Yet, the proposed DNA-based method is much faster, cost-effective and can be used even by non-geneticists, in any laboratory having access to an HRM-capable real-time PCR instrumentation. It can be, thus, regarded as a strong analytical tool in saffron authentication studies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Adulteration and cultivation region identification of American ginseng using HPLC coupled with multivariate analysis

    PubMed Central

    Yu, Chunhao; Wang, Chong-Zhi; Zhou, Chun-Jie; Wang, Bin; Han, Lide; Zhang, Chun-Feng; Wu, Xiao-Hui; Yuan, Chun-Su

    2014-01-01

    American ginseng (Panax quinquefolius) is originally grown in North America. Due to price difference and supply shortage, American ginseng recently has been cultivated in northern China. Further, in the market, some Asian ginsengs are labeled as American ginseng. In this study, forty-three American ginseng samples cultivated in the USA, Canada or China were collected and 14 ginseng saponins were determined using HPLC. HPLC coupled with hierarchical cluster analysis and principal component analysis was developed to identify the species. Subsequently, an HPLC-linear discriminant analysis was established to discriminate cultivation regions of American ginseng. This method was successfully applied to identify the sources of 6 commercial American ginseng samples. Two of them were identified as Asian ginseng, while 4 others were identified as American ginseng, which were cultivated in the USA (3) and China (1). Our newly developed method can be used to identify American ginseng with different cultivation regions. PMID:25044150

  11. Combined HPLC-CUPRAC (cupric ion reducing antioxidant capacity) assay of parsley, celery leaves, and nettle.

    PubMed

    Yildiz, Leyla; Başkan, Kevser Sözgen; Tütem, Esma; Apak, Reşat

    2008-10-19

    This study aims to identify the essential antioxidant compounds present in parsley (Petroselinum sativum) and celery (Apium graveolens) leaves belonging to the Umbelliferae (Apiaceae) family, and in stinging nettle (Urtica dioica) belonging to Urticaceae family, to measure the total antioxidant capacity (TAC) of these compounds with CUPRAC (cupric ion reducing antioxidant capacity) and ABTS spectrophotometric methods, and to correlate the TAC with high performance liquid chromatography (HPLC) findings. The CUPRAC spectrophotometric method of TAC assay using copper(II)-neocuproine (2,9-dimethyl-1,10-phenanthroline) as the chromogenic oxidant was developed in our laboratories. The individual antioxidant constituents of plant extracts were identified and quantified by HPLC on a C18 column using a modified mobile phase of gradient elution comprised of MeOH-0.2% o-phosphoric acid and UV detection for polyphenols at 280 nm. The TAC values of HPLC-quantified antioxidant constituents were found, and compared for the first time with those found by CUPRAC. The TAC of HPLC-quantified compounds accounted for a relatively high percentage of the observed CUPRAC capacities of plant extracts, namely 81% of nettle, 60-77% of parsley (in different hydrolyzates of extract and solid sample), and 41-57% of celery leaves (in different hydrolyzates). The CUPRAC total capacities of the 70% MeOH extracts of studied plants (in the units of mmol trolox g(-1)plant) were in the order: celery leaves>nettle>parsley. The TAC calculated with the aid of HPLC-spectrophotometry did not compensate for 100% of the CUPRAC total capacities, because all flavonoid glycosides subjected to hydrolysis were either not detectable with HPLC, or not converted to the corresponding aglycons (i.e., easily detectable and quantifiable with HPLC) during the hydrolysis step.

  12. Rapid, Standardized Method for Determination of Mycobacterium tuberculosis Drug Susceptibility by Use of Mycolic Acid Analysis▿

    PubMed Central

    Parrish, Nicole; Osterhout, Gerard; Dionne, Kim; Sweeney, Amy; Kwiatkowski, Nicole; Carroll, Karen; Jost, Kenneth C.; Dick, James

    2007-01-01

    Multidrug-resistant (MDR) Mycobacterium tuberculosis and extrensively drug-resistant (XDR) M. tuberculosis are emerging public health threats whose threats are compounded by the fact that current techniques for testing the susceptibility of M. tuberculosis require several days to weeks to complete. We investigated the use of high-performance liquid chromatography (HPLC)-based quantitation of mycolic acids as a means of rapidly determining drug resistance and susceptibility in M. tuberculosis. Standard susceptibility testing and determination of the MICs of drug-susceptible (n = 26) and drug-resistant M. tuberculosis strains, including MDR M. tuberculosis strains (n = 34), were performed by using the Bactec radiometric growth system as the reference method. The HPLC-based susceptibilities of the current first-line drugs, isoniazid (INH), rifampin (RIF), ethambutol (EMB), and pyrazinamide (PZA), were determined. The vials were incubated for 72 h, and aliquots were removed for HPLC analysis by using the Sherlock mycobacterial identification system. HPLC quantitation of total mycolic acid peaks (TMAPs) was performed with treated and untreated cultures. At 72 h, the levels of agreement of the HPLC method with the reference method were 99.5% for INH, EMB, and PZA and 98.7% for RIF. The inter- and intra-assay reproducibilities varied by drug, with an average precision of 13.4%. In summary, quantitation of TMAPs is a rapid, sensitive, and accurate method for antibiotic susceptibility testing of all first-line drugs currently used against M. tuberculosis and offers the potential of providing susceptibility testing results within hours, rather than days or weeks, for clinical M. tuberculosis isolates. PMID:17913928

  13. HPLC-MS/MS methods for the determination of 52 perfluoroalkyl and polyfluoroalkyl substances in aqueous samples.

    PubMed

    Gremmel, Christoph; Frömel, Tobias; Knepper, Thomas P

    2017-02-01

    Two quantitative methods using high-performance liquid chromatography (HPLC) combined with triple quadrupole tandem mass spectrometry (MS/MS) were developed to determine perfluoroalkyl and polyfluoroalkyl substances (PFASs) in aqueous samples. The first HPLC-MS/MS method was applied to 47 PFASs of 12 different substance classes with acidic characteristics such as perfluoroalkyl carboxylic acids (PFCAs) and perfluoroalkane sulfonic acids (PFSAs), as well as precursor substances and biotransformation intermediates (e.g., unsaturated fluorotelomer carboxylic acids). In addition, 25 13 C-, 18 O-, and 2 H-labeled PFASs were used as internal standards in this method. The second HPLC-MS/MS method was applied to fluorotelomer alcohols (FTOHs) and perfluorooctane sulfonamidoethanols as these compounds have physicochemical properties different from those of the previous ones. Accuracy between 82% and 110% and a standard deviation in the range from 2% to 22% depending on the substances were determined during the evaluation of repeatability and precision. The method quantification limit after solid-phase extraction ranged from 0.3 to 199 ng/L depending on the analyte and matrix. The HPLC-MS/MS methods developed were suitable for the determination of PFASs in aqueous samples (e.g., wastewater treatment plant effluents or influents after solid-phase extraction). These methods will be helpful in monitoring campaigns to evaluate the relevance of precursor substances as indirect sources of perfluorinated substances in the environment. In one exemplary application in an industrial wastewater treatment plant, FTOHs were found to be the major substance class in the influent; in particular, 6:2-FTOH was the predominant compound in the industrial samples and accounted for 74% of the total PFAS concentration. The increase in the concentration of the transformation products of FTOHs in the corresponding effluent, such as fluorotelomer carboxylic acids, unsaturated fluorotelomer carboxylic acids, n:3 polyfluorinated saturated carboxylic acids (n indicates the number of nonfluorinated carbon atoms), and PFCAs, indicated biotransformation of FTOHs or their derivatives during wastewater treatment. However, only 33 mol% of the total amount of PFASs present in the influent was quantified in the corresponding effluent. Graphical abstract Method development of an HPLC-MS/MS multi-method for the determination of PFASs in aqueos samples.

  14. Conventional steaming retains tocols and γ-oryzanol better than boiling and frying in the jasmine rice variety Khao dok mali 105.

    PubMed

    Srichamnong, Warangkana; Thiyajai, Parunya; Charoenkiatkul, Somsri

    2016-01-15

    The aim of this study was to determine the effect of various cooking methods on the white rice (WR), brown rice (BR) and parboiled geminated brown rice (PGBR) of the same variety, focusing on γ-oryzanol and tocols. The methods used for analysis of γ-oryzanol and tocols included solvent extraction and HPLC. The results indicated that PGBR had a higher content of γ-oryzanol and tocols compared to BR and WR, when different cooking methods (raw, steamed, boiled and fried) were used. Steaming method retained the higher γ-oryzanol content (53.6-62.2mg/100g) in both PGBR and BR, in comparison with boiling (53.0-60.6mg/100g) and frying (23.4-31.5mg/100g) methods. Frying reduced the γ-oryzanol content significantly regardless of the rice type. Regarding tocols, a similar trend was noticed in all the methods studied. Tocotrienol was the most abundant tocol found in PGBR and BR. Therefore, steaming is the best cooking method to preserved most of the bioactive compounds; however, a slight increase in total tocols was observed after frying. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. LC-NMR Technique in the Analysis of Phytosterols in Natural Extracts

    PubMed Central

    Horník, Štěpán; Sajfrtová, Marie; Sýkora, Jan; Březinová, Anna; Wimmer, Zdeněk

    2013-01-01

    The ability of LC-NMR to detect simultaneously free and conjugated phytosterols in natural extracts was tested. The advantages and disadvantages of a gradient HPLC-NMR method were compared to the fast composition screening using SEC-NMR method. Fractions of free and conjugated phytosterols were isolated and analyzed by isocratic HPLC-NMR methods. The results of qualitative and quantitative analyses were in a good agreement with the literature data. PMID:24455424

  16. Simultaneous separation and quantitation of amino acids and polyamines of forest tree tissues and cell cultures within a single high-performance liquid chromatography run using dansyl derivatization

    Treesearch

    Rakesh Minocha; Stephanie Long

    2004-01-01

    The objective of the present study was to develop a rapid HPLC method for simultaneous separation and quantitation of dansylated amino acids and common polyamines in the same matrix for analyzing forest tree tissues and cell cultures. The major modifications incorporated into this method as compared to previously published HPLC methods for separation of only dansyl...

  17. Combined Application of UHPLC-QTOF/MS, HPLC-ELSD and 1 H-NMR Spectroscopy for Quality Assessment of DA-9801, A Standardised Dioscorea Extract.

    PubMed

    Kang, Kyo Bin; Ryu, Jayoung; Cho, Youngwoong; Choi, Sang-Zin; Son, Miwon; Sung, Sang Hyun

    2017-05-01

    DA-9801, a standardised 50% aqueous ethanolic extract of a mixture of Dioscorea japonica and D. nipponica, is a botanical drug candidate for the treatment of diabetic neuropathy, which finished its US phase II clinical trials recently. An advanced quality control method is needed for further development of DA-9801, considering its high contents of both primary and secondary metabolites. Development of a quality assessment strategy for DA-9801, based on the combination of UHPLC-QTOF/MS, HPLC-ELSD, and 1 H-NMR spectroscopy. The method was developed and tested with 15 batch products of DA-9801. The steroidal saponins of DA-9801 were tentatively identified by UHPLC-QTOF/MS and were quantified with the validated HPLC-ELSD method. Primary metabolites of DA-9801 were identified and profiled using 1 H-NMR spectrometry. The batch-to-batch equivalence of DA-9801 was tested with the 1 H-NMR spectra using spectral binning, correlation analysis, and principal component analysis. Six major saponins of DA-9801 were tentatively identified by UHPLC-QTOF/MS. Among them, protodioscin and dioscin were quantified by the validated HPLC-ELSD method. Twenty-six metabolites were identified in 1 H-NMR spectra. The similarity between DA-9801 batches could be evaluated with the NMR spectra of DA-9801. The 1 H-NMR method also revealed that two Dioscorea species contributed distinct amino acids to the contents of DA-9801. This study validates the effectiveness of UHPLC-QTOF/MS, HPLC-ELSD, and 1 H NMR-combined method for quality control of DA-9801 and its crude materials. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Quantitative HPLC Analysis of Rosmarinic Acid in Extracts of "Melissa officinalis" and Spectrophotometric Measurement of Their Antioxidant Activities

    ERIC Educational Resources Information Center

    Canelas, Vera; da Costa, Cristina Teixeira

    2007-01-01

    The students prepare tea samples using different quantities of lemon balm leaves ("Melissa officinalis") and measure the rosmarinic acid contents by an HPLC-DAD method. The antioxidant properties of the tea samples are evaluated by a spectrophotometric method using a radical-scavenging assay with DPPH. (2,2-diphenyl-1-picrylhydrazyl). Finally the…

  19. Quantitative determination of a-Arbutin, ß-Arbutin, Kojic acid, nicotinamide, hydroquinone, resorcinol, 4-methoxyphenol, 4-ethoxyphenol and ascorbic acid from skin whitening Products by HPLC-UV

    USDA-ARS?s Scientific Manuscript database

    Development of an analytical method for the simultaneous determination of multifarious skin whitening agents will provide an efficient tool to analyze skin whitening cosmetics. An HPLC-UV method was developed for quantitative analysis of six commonly used whitening agents, a-arbutin, ß-arbutin, koji...

  20. Demonstration and Evaluation of Solid Phase Microextraction for the Assessment of Bioavailability and Contaminant Mobility

    DTIC Science & Technology

    2012-05-01

    methods demonstrated that desorption into solvents suitable for subsequent chemical analysis (into acetonitrile for HPLC analysis or hexane for GC...SPME. Analysis by HPLC with EPA 8310 with fluorescent detection. a) surface water quality criteria (NRWQC) are given for comparison to detection... analysis ) or hexane (for PCB analysis ) was added to the inserts. The vials were then analyzed directly by HPLC (PAHs) or GC-ECD (PCBs). Fiber achieved

  1. Automated solid-phase extraction coupled online with HPLC-FLD for the quantification of zearalenone in edible oil.

    PubMed

    Drzymala, Sarah S; Weiz, Stefan; Heinze, Julia; Marten, Silvia; Prinz, Carsten; Zimathies, Annett; Garbe, Leif-Alexander; Koch, Matthias

    2015-05-01

    Established maximum levels for the mycotoxin zearalenone (ZEN) in edible oil require monitoring by reliable analytical methods. Therefore, an automated SPE-HPLC online system based on dynamic covalent hydrazine chemistry has been developed. The SPE step comprises a reversible hydrazone formation by ZEN and a hydrazine moiety covalently attached to a solid phase. Seven hydrazine materials with different properties regarding the resin backbone, pore size, particle size, specific surface area, and loading have been evaluated. As a result, a hydrazine-functionalized silica gel was chosen. The final automated online method was validated and applied to the analysis of three maize germ oil samples including a provisionally certified reference material. Important performance criteria for the recovery (70-120 %) and precision (RSDr <25 %) as set by the Commission Regulation EC 401/2006 were fulfilled: The mean recovery was 78 % and RSDr did not exceed 8 %. The results of the SPE-HPLC online method were further compared to results obtained by liquid-liquid extraction with stable isotope dilution analysis LC-MS/MS and found to be in good agreement. The developed SPE-HPLC online system with fluorescence detection allows a reliable, accurate, and sensitive quantification (limit of quantification, 30 μg/kg) of ZEN in edible oils while significantly reducing the workload. To our knowledge, this is the first report on an automated SPE-HPLC method based on a covalent SPE approach.

  2. Two-dimensional multi-heart cutting centrifugal partition chromatography-liquid chromatography for the preparative isolation of antioxidants from Edelweiss plant.

    PubMed

    Marlot, Léa; Batteau, Magali; Escofet, Marie-Claire; Nuccio, Sylvie; Coquoin, Véronique; De Vaumas, René; Faure, Karine

    2017-06-30

    The Edelweiss plant has been recognized as a very valuable source of anti-aging principles due to its composition of antioxidants compounds: leontopodic acid A and 3,5-dicaffeoylquinic acid. In this work, off-line multi-heart cutting CPC-LC separation was set up at industrial scale in order to isolate and produce new high quality reference material of these two antioxidants from Edelweiss. For this purpose, CPC and HPLC methods were developed and optimized at laboratory scale and a comprehensive CPCxHPLC analysis of the crude extract was established. Thereby, the CPC method led to a first separation of the target compounds according to their partition coefficient in the solvent system and the HPLC method was performed on the recovered fractions to lead to a second separation. A 2D CPCxHPLC plot was established in order to know the fractions to select at the industrial scale. Then, the CPC and HPLC methods were transferred at industrial scale and the multi-heart cutting CPC-LC was performed in off-line mode. Using CPC with methyl ter-butyl ether-water 1:1 (v/v) solvent system and LC with Denali C18 column, 2g of crude extract sample were injected and leontopodic acid A and 3,5-dicaffeoylquinic acid were recovered with purity over 97%. The compounds were identified by MS and NMR. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Assessment of cosmetic ingredients in the in vitro reconstructed human epidermis test method EpiSkin™ using HPLC/UPLC-spectrophotometry in the MTT-reduction assay.

    PubMed

    Alépée, N; Hibatallah, J; Klaric, M; Mewes, K R; Pfannenbecker, U; McNamee, P

    2016-06-01

    Cosmetics Europe recently established HPLC/UPLC-spectrophotometry as a suitable alternative endpoint detection system for measurement of formazan in the MTT-reduction assay of reconstructed human tissue test methods irrespective of the test system involved. This addressed a known limitation for such test methods that use optical density for measurement of formazan and may be incompatible for evaluation of strong MTT reducer and/or coloured chemicals. To build on the original project, Cosmetics Europe has undertaken a second study that focuses on evaluation of chemicals with functionalities relevant to cosmetic products. Such chemicals were primarily identified from the Scientific Committee on Consumer Safety (SCCS) 2010 memorandum (addendum) on the in vitro test EpiSkin™ for skin irritation testing. Fifty test items were evaluated in which both standard photometry and HPLC/UPLC-spectrophotometry were used for endpoint detection. The results obtained in this study: 1) provide further support for Within Laboratory Reproducibility of HPLC-UPLC-spectrophotometry for measurement of formazan; 2) demonstrate, through use a case study with Basazol C Blue pr. 8056, that HPLC/UPLC-spectrophotometry enables determination of an in vitro classification even when this is not possible using standard photometry and 3) addresses the question raised by SCCS in their 2010 memorandum (addendum) to consider an endpoint detection system not involving optical density quantification in in vitro reconstructed human epidermis skin irritation test methods. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Identification of new impurities of enalapril maleate on oxidation in the presence of magnesium monoperoxyphthalate.

    PubMed

    Toporisic, Rebeka; Mlakar, Anita; Hvala, Jernej; Prislan, Iztok; Zupancic-Kralj, Lucija

    2010-06-05

    Stress stability testing and forced degradation were used to determine the stability of enalapril maleate (EM) and to find a degradation pathway for the drug. The degradation impurities, formed under different stressed conditions, were investigated by HPLC and UPLC-MS methods. HPLC analysis showed several degradation impurities of which several were already determined, but on oxidation in the presence of magnesium monoperoxyphthalate (MMPP) several impurities of EM were observed which were not yet characterized. The HPLC methods for determination of EM were validated. The linearity of HPLC method was established in the concentration range between 0.5 and 10 microg/mL with correlation coefficient greater than 0.99. The LOD of EM was 0.2 microg/mL and LOQ was 0.5 microg/mL. The validated HPLC method was used to determine the degradation impurities in samples after stress stability testing and forced degradation of EM. In order to identify new degradation impurities of EM after forced degradation UPLC-MS/MS(n), Orbitrap has been used. It was found that new impurities are oxidation products: (S)-1-((S)-2-((S)-1-ethoxy-4-(o,m,p-hydroxyphenyl)-1-oxobutan-2-ylamino)propanoyl)pyrrolidine-2-carboxylic acid, (2S)-1-((2S)-2-((2S)-1-ethoxy-4-hydroxy-1-oxo-4-phenylbutan-2-ylamino)propanoyl)pyrrolidine-2-carboxylic acid. (S)-2-(3-phenylpropylamino)-1-(pyrrolidin-1-yl)propan-1-one was identified as a new degradation impurity. Copyright (c) 2010. Published by Elsevier B.V.

  5. HPLC analysis and standardization of Brahmi vati - An Ayurvedic poly-herbal formulation.

    PubMed

    Mishra, Amrita; Mishra, Arun K; Tiwari, Om Prakash; Jha, Shivesh

    2013-09-01

    The aim of the present study was to standardize Brahmi vati (BV) by simultaneous quantitative estimation of Bacoside A3 and Piperine adopting HPLC-UV method. BV very important Ayurvedic polyherbo formulation used to treat epilepsy and mental disorders containing thirty eight ingredients including Bacopa monnieri L. and Piper longum L. An HPLC-UV method was developed for the standardization of BV in light of simultaneous quantitative estimation of Bacoside A3 and Piperine, the major constituents of B. monnieri L. and P. longum L. respectively. The developed method was validated on parameters including linearity, precision, accuracy and robustness. The HPLC analysis showed significant increase in amount of Bacoside A3 and Piperine in the in-house sample of BV when compared with all three different marketed samples of the same. Results showed variations in the amount of Bacoside A3 and Piperine in different samples which indicate non-uniformity in their quality which will lead to difference in their therapeutic effects. The outcome of the present investigation underlines the importance of standardization of Ayurvedic formulations. The developed method may be further used to standardize other samples of BV or other formulations containing Bacoside A3 and Piperine.

  6. Simultaneous determination of three polyphenols in rat plasma after orally administering hawthorn leaves extract by the HPLC method.

    PubMed

    Ying, Xixiang; Meng, Xiansheng; Wang, Siyuan; Wang, Dong; Li, Haibo; Wang, Bing; Du, Yang; Liu, Xun; Zhang, Wenjie; Kang, Tingguo

    2012-01-01

    A simple and sensitive HPLC method was developed to simultaneously determine three active compounds, vitexin-4″-O-glucoside (VG), vitexin-2″-O-rhamnoside (VR) and hyperoside (HP), in rat plasma after administering the hawthorn leaves extract (HLE). An HPLC assay with baicalin as the internal standard was carried out using a Phenomsil C₁₈ analytical column with UV detection at 332 nm. The mobile phase consisted of methanol-acetonitrile-tetrahydrofuran-1% glacial acetic acid (6 : 1.5 : 18.5 : 74, v/v/v/v). The calibration curves were linear over the range of 2.5-500, 0.2-25 and 0.25-12.5 µg mL⁻¹ for VG, VR and HP, respectively. The method was reproducible and reliable, with relative standard deviations of the intra- and inter-day precision between 1.2% and 13.2% for the analysis of the three analytes. The validated HPLC method herein described was successfully applied to the pharmacokinetic study of VG, VR and HP after oral administration of HLE to rats over the dose range of 2.5-10  mL kg⁻¹.

  7. On-line MSPD-SPE-HPLC/FLD analysis of polycyclic aromatic hydrocarbons in bovine tissues.

    PubMed

    Gutiérrez-Valencia, Tania M; García de Llasera, Martha P

    2017-05-15

    A fast method was optimized and validated for simultaneous trace determination of four polycyclic aromatic hydrocarbons: benzo[a]anthracene, benzo[b]fluoranthene, benzo[k]fluoranthene and benzo[a]pyrene in bovine tissues. The determination was performed by matrix solid-phase dispersion (MSPD) coupled on-line to solid phase extraction (SPE) and high performance liquid chromatography (HPLC) with fluorescence detection (FLD). The sample was dispersed on C 18 silica sorbent and then the on-line MSPD-SPE-HPLC/FLD method was applied. Several parameters were optimized: cleaning and elution sequences applied to the MSPD cartridge, the flow rate and dilution of extract used for SPE loading. The on-line method was validated over a concentration range of 0.1-0.6ngg -1 obtaining good linearity (r⩾0.998) and precision (RSD)⩽10%. Recovery ranged from 96 to 99% and the limits of detection were 0.012ngg -1 . This methodology was applied to liver samples from unhealthy animals. The results demonstrate that MSDP-SPE-HPLC/FLD method provides reliable, sensitive, accurate and fast data to the food control. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Ultrafast UPLC-ESI-MS and HPLC with monolithic column for determination of principal flavor compounds in vanilla pods.

    PubMed

    Sharma, Upendra K; Sharma, Nandini; Sinha, Arun K; Kumar, Neeraj; Gupta, Ajai P

    2009-10-01

    In this study, two novel chromatographic methods based on monolithic column high-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) were developed for the ultrafast determination of principal flavor compounds namely vanillin, vanillic acid, p-hydroxybenzoic acid, and p-hydroxybenzaldehyde in ethanolic extracts of Vanilla planifolia pods. Good separation was achieved within 2.5 min using Chromolith RP18e column (100 mm x 4.6 mm) for HPLC and Acquity BEH C-18 (100 mm x 2.1 mm, 1.7 microm) column for UPLC. Both methods were compared in terms of total analysis time, mobile phase consumption, sensitivity, and validation parameters like precision, accuracy, LOD, and LOQ. Further, system suitability test data including resolution, capacity factor, theoretical plates, and tailing factor was determined for both the methods by ten replicate injections. Monolithic column based HPLC gave better results for most of the selected parameters while UPLC was found to be more eco-friendly with low mobile phase consumption and better sensitivity. Both methods may be used conveniently for the high throughput analysis of large number of samples in comparison to traditional particulate column.

  9. Evaluation of tamoxifen and metabolites by LC-MS/MS and HPLC methods.

    PubMed

    Heath, D D; Flat, S W; Wu, A H B; Pruitt, M A; Rock, C L

    2014-01-01

    Epidemiological and laboratory evidence suggests that quantification of serum or plasma levels of tamoxifen and its metabolites, 4-hydroxy-N-desmethyl-tamoxifen (endoxifen), Z-4-hydroxytamoxifen (4HT), N-desmethyl-tamoxifen (ND-tam), is a clinically useful tool in the assessment and monitoring of breast cancer status in patients taking adjuvant tamoxifen. A liquid chromatographic mass spectrometric method (LC-MS/MS) was used to measure the blood levels of tamoxifen and its metabolites. This fully automated analytical method is specific, accurate and sensitive. The LC-MS/MS automated technique has now become a widely accepted reference method. This study analysed a randomly selected batch of blood samples from participants enrolled in a breast cancer study to compare results from this reference method in 40 samples with those obtained from a recently developed high-performance liquid chromatography (HPLC) method with fluorescence detection. The mean (SD) concentrations for the LC-MS/MS method (endoxifen 12.6 [7.5] ng/mL, tamoxifen 105 [44] ng/mL, 4-HT 1.9 [1.0] ng/mL, ND-tam 181 [69] ng/mL) and the HPLC method (endoxifen 13.1 [7.8] ng/mL, tamoxifen 108 [55] ng/mL, 4-HT 1.8 [0.8] ng/mL, ND-tam 184 [81] ng/mL) did not show any significant differences. The results confirm that the HPLC method offers an accurate and comparable alternative for the quantification of tamoxifen and tamoxifen metabolites.

  10. Competitive Protein-binding assay-based Enzyme-immunoassay Method, Compared to High-pressure Liquid Chromatography, Has a Very Lower Diagnostic Value to Detect Vitamin D Deficiency in 9-12 Years Children.

    PubMed

    Zahedi Rad, Maliheh; Neyestani, Tirang Reza; Nikooyeh, Bahareh; Shariatzadeh, Nastaran; Kalayi, Ali; Khalaji, Niloufar; Gharavi, Azam

    2015-01-01

    The most reliable indicator of Vitamin D status is circulating concentration of 25-hydroxycalciferol (25(OH) D) routinely determined by enzyme-immunoassays (EIA) methods. This study was performed to compare commonly used competitive protein-binding assays (CPBA)-based EIA with the gold standard, high-pressure liquid chromatography (HPLC). Concentrations of 25(OH) D in sera from 257 randomly selected school children aged 9-11 years were determined by two methods of CPBA and HPLC. Mean 25(OH) D concentration was 22 ± 18.8 and 21.9 ± 15.6 nmol/L by CPBA and HPLC, respectively. However, mean 25(OH) D concentrations of the two methods became different after excluding undetectable samples (25.1 ± 18.9 vs. 29 ± 14.5 nmol/L, respectively; P = 0.04). Based on predefined Vitamin D deficiency as 25(OH) D < 12.5 nmol/L, CPBA sensitivity and specificity were 44.2% and 60.6%, respectively, compared to HPLC. In receiver operating characteristic curve analysis, the best cut-offs for CPBA was 5.8 nmol/L, which gave 82% sensitivity, but specificity was 17%. Though CPBA may be used as a screening tool, more reliable methods are needed for diagnostic purposes.

  11. Chiral separation of the β2-sympathomimetic fenoterol by HPLC and capillary zone electrophoresis for pharmacokinetic studies.

    PubMed

    Ullrich, Thomas; Wesenberg, Dirk; Bleuel, Corinna; Krauss, Gerd-Joachim; Schmid, Martin G; Weiss, Michael; Gübitz, Gerald

    2010-10-01

    The development of methods for the separation of the enantiomers of fenoterol by chiral HPLC and capillary zone electrophoresis (CZE) is described. For the HPLC separation precolumn fluorescence derivatization with naphthyl isocyanate was applied. The resulting urea derivatives were resolved on a cellulose tris(3,5-dimethylphenylcarbamate)-coated silica gel column employing a column switching procedure. Detection was carried out fluorimetrically with a detection limit in the low ng/mL range. The method was adapted to the determination of fenoterol enantiomers in rat heart perfusates using liquid-liquid extraction. As an alternative a CE method was used for the direct separation of fenoterol enantiomers comparing different cyclodextrin derivatives as chiral selectors. Copyright © 2010 John Wiley & Sons, Ltd.

  12. Cholesterol concentrations in lipoprotein fractions separated by anion-exchange-high-performance liquid chromatography in healthy dogs and dogs with hypercholesterolemia.

    PubMed

    Oda, Hitomi; Mori, Akihiro; Hirowatari, Yuji; Takoura, Toshie; Manita, Daisuke; Takahashi, Tomoya; Shono, Saori; Onozawa, Eri; Mizutani, Hisashi; Miki, Yohei; Itabashi, Yukiko; Sako, Toshinori

    2017-10-01

    Anion-exchange (AEX)-high-performance liquid chromatography (HPLC) for measurement of cholesterol can be used to separate serum lipoproteins (high-density lipoprotein (HDL); low-density lipoprotein (LDL); intermediate-density lipoprotein (IDL); very-low-density lipoprotein (VLDL)) in humans. However, AEX-HPLC has not been applied in veterinary practice. We had three objectives: (i) the validation of AEX-HPLC methods including the correlation of serum cholesterol concentration in lipoprotein fraction measured by AEX-HPLC and gel permeation-HPLC (GP-HPLC) in healthy dogs and those with hypercholesterolemia was investigated; (ii) the reference intervals of lipoprotein fractions measured by AEX-HPLC from healthy dogs (n=40) was established; (iii) lipoprotein fractions from the serum of healthy dogs (n=12) and dogs with hypercholesterolemia (n=23) were compared. Analytic reproducibility and precision of AEX-HPLC were acceptable. Positive correlation between serum concentrations of total cholesterol (Total-Chol), HDL cholesterol (HDL-Chol), LDL cholesterol (LDL-Chol)+IDL cholesterol (IDL-Chol), and VLDL cholesterol (VLDL-Chol) was noted for AEX-HPLC and GP-HPLC in healthy dogs and dogs with hypercholesterolemia. Reference intervals measured by AEX-HPLC for serum concentrations of Total-Chol, HDL-Chol, and LDL-Chol were determined to be 2.97-9.32, 2.79-6.57, 0.16-3.28mmol/L (2.5-97.5% interval), respectively. Furthermore, there was significant difference in lipoprotein profiles between healthy and dogs with hypercholesterolemia. These results suggest that AEX-HPLC can be used to evaluate lipoprotein profiles in dogs and could be a new useful indicator of hyperlipidemia in dogs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Identification, characterization, synthesis and HPLC quantification of new process-related impurities and degradation products in retigabine.

    PubMed

    Douša, Michal; Srbek, Jan; Rádl, Stanislav; Cerný, Josef; Klecán, Ondřej; Havlíček, Jaroslav; Tkadlecová, Marcela; Pekárek, Tomáš; Gibala, Petr; Nováková, Lucie

    2014-06-01

    Two new impurities were described and determined using gradient HPLC method with UV detection in retigabine (RET). Using LC-HRMS, NMR and IR analysis the impurities were identified as RET-dimer I: diethyl {4,4'-diamino-6,6'-bis[(4-fluorobenzyl)amino]biphenyl-3,3'-diyl}biscarbamate and RET-dimer II: ethyl {2-amino-5-[{2-amino-4-[(4-fluorobenzyl) amino] phenyl} (ethoxycarbonyl) amino]-4-[(4-fluorobenzyl)amino] phenyl}carbamate. Reference standards of these impurities were synthesized followed by semipreparative HPLC purification. The mechanism of the formation of these impurities is also discussed. An HPLC method was optimized in order to separate, selectively detect and quantify all process-related impurities and degradation products of RET. The presented method, which was validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ) and selectivity is very quick (less than 11min including re-equilibration time) and therefore highly suitable for routine analysis of RET related substances as well as stability studies. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Analysis of Poly-β-Hydroxybutyrate in Rhizobium japonicum Bacteroids by Ion-Exclusion High-Pressure Liquid Chromatography and UV Detection †

    PubMed Central

    Karr, Dale B.; Waters, James K.; Emerich, David W.

    1983-01-01

    Ion-exclusion high-pressure liquid chromatography (HPLC) was used to measure poly-β-hydroxybutyrate (PHB) in Rhizobium japonicum bacteroids. The products in the acid digest of PHB-containing material were fractionated by HPLC on Aminex HPX-87H ion-exclusion resin for organic acid analysis. Crotonic acid formed from PHB during acid digestion was detected by its intense absorbance at 210 nm. The Aminex-HPLC method provides a rapid and simple chromatographic technique for routine analysis of organic acids. Results of PHB analysis by Aminex-HPLC were confirmed by gas chromatography and spectrophotometric analysis. PMID:16346443

  15. Quantitative determination of limonin in citrus juices by HPLC using computerized solvent optimization.

    PubMed

    Shaw, P E; Wilson, C W

    1988-09-01

    The commercially available computer program, Drylab, for optimization of separations by high-performance liquid chromatography (HPLC) using binary solvent mixtures is used to improve an HPLC method for separation of the bitter principle, limonin, in grapefruit and navel orange juices. Best conditions for separation of limonin in a reasonable time are 30 to 32% acetonitrile in water at 0.9 mL/min using a 5-micron C18 column 10 cm long. These conditions are used to analyze grapefruit and navel orange juice samples, and these HPLC results are compared with values determined by enzyme immunoassay or thin-layer chromatography (TLC) on the same samples.

  16. Degradation of components in drug formulations: a comparison between HPLC and DSC methods.

    PubMed

    Ceschel, G C; Badiello, R; Ronchi, C; Maffei, P

    2003-08-08

    Information about the stability of drug components and drug formulations is needed to predict the shelf-life of the final products. The studies on the interaction between the drug and the excipients may be carried out by means of accelerated stability tests followed by analytical determination of the active principle (HPLC and other methods) and by means of the differential scanning calorimetry (DSC). This research has been focused to the acetyl salicylic acid (ASA) physical-chemical characterisation by using DSC method in order to evaluate its compatibility with some of the most used excipients. It was possible to show, with the DSC method, the incompatibility of magnesium stearate with ASA; the HPLC data confirm the reduction of ASA concentration in the presence of magnesium stearate. With the other excipients the characteristic endotherms of the drug were always present and no or little degradation was observed with the accelerated stability tests. Therefore, the results with the DSC method are comparable and in good agreement with the results obtained with other methods.

  17. Comparison of cyclosporine determinations in whole blood by three different methods. HPLC, /sup 125/I RIA and /sup 3/H RIA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, W.Y.; Lipsey, A.I.; Cheng, M.H.

    1987-04-01

    The authors have analyzed and compared the cyclosporine concentrations in whole blood specimens from pediatric renal transplant patients using three different methods: high-performance liquid chromatography (HPLC) (5u C18 reverse-phase column), /sup 3/H radioimmunoassay (RIA), and /sup 125/I RIA (substituted /sup 3/H-tracer in Sandoz Kit with /sup 125/I tracer. Results obtained by the /sup 125/I RIA correlated well with results obtained by the /sup 3/H RIA. Both RIA methods had similar correlation with the HPLC method. The /sup 125/I RIA method showed higher sensitivity and greater precision than the /sup 3/H RIA method. The authors conclude that the /sup 125/I RIAmore » method can be used for cyclosporine determination in whole blood specimens. The use of the /sup 125/I RIA provides a simple and rapid method with higher counting efficiency and less background quenching than the /sup 3/H RIA method, which requires cumbersome liquid scintillation counting procedures.« less

  18. Spectrophotometric and HPLC determinations of anti-diabetic drugs, rosiglitazone maleate and metformin hydrochloride, in pure form and in pharmaceutical preparations.

    PubMed

    Onal, Armağan

    2009-12-01

    In this study, three spectrophotometric methods and one HPLC method were developed for analysis of anti-diabetic drugs in tablets. The two spectrophotometric methods were based on the reaction of rosiglitazone (RSG) with 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) and bromocresol green (BCG). Linear relationship between the absorbance at lambda(max) and the drug concentration was found to be in the ranges 6.0-50.0 and 1.5-12 microg ml(-1) for DDQ and BCG methods, respectively. The third spectrophotometric method consists of a zero-crossing first-derivative spectrophotometric method for simultaneous analysis of RSG and metformin (MTF) in tablets. The calibration curves were linear within the concentration ranges of 5.0-50 microg ml(-1) for RSG and 1.0-10.0 microg ml(-1) for MTF. The fourth method is a rapid stability-indicating HPLC method developed for the determination of RSG. A linear response was observed within the concentration range of 0.25-2.5 microg ml(-1). The proposed methods have been successfully applied to the tablet analysis.

  19. Ionic liquid-based microwave-assisted extraction for the determination of flavonoid glycosides in pigeon pea leaves by high-performance liquid chromatography-diode array detector with pentafluorophenyl column.

    PubMed

    Wei, Wei; Fu, Yu-jie; Zu, Yuan-gang; Wang, Wei; Luo, Meng; Zhao, Chun-jian; Li, Chun-ying; Zhang, Lin; Wei, Zuo-fu

    2012-11-01

    In this study, an ionic liquid-based microwave-assisted extraction (ILMAE) followed by high-performance liquid chromatography-diode array detector with a pentafluorophenyl column for the extraction and quantification of eight flavonoid glycosides in pigeon pea leaves is described. Compared with conventional extraction methods, ILMAE is a more effective and environment friendly method for the extraction of nature compounds from herbal plants. Nine different types of ionic liquids with different cations and anions were investigated. The results suggested that varying the anion and cation had significant effects on the extraction of flavonoid glycosides, and 1.0 M 1-butyl-3-methylimidazolium bromide ([C4MIM]Br) solution was selected as solvent. In addition, the extraction procedures were also optimized using a series of single-factor experiments. The optimum parameters were obtained as follows: extraction temperature 60°C, liquid-solid ratio 20:1 mL/g and extraction time 13 min. Moreover, an HPLC method using pentafluorophenyl column was established and validated. Good linearity was observed with the regression coefficients (r(2)) more than 0.999. The limit of detection (LODs) (S/N = 3) and limit of quantification (LOQs) (S/N = 10) for the components were less than 0.41 and 1.47 μg/mL, respectively. The inter- and intraday precisions that were used to evaluate the reproducibility and relative standard deviation (RSD) values were less than 4.57%. The recoveries were between 97.26 and 102.69%. The method was successfully used for the analysis of samples of pigeon pea leaves. In conclusion, the developed ILMAE-HPLC-diode array detector using pentafluorophenyl column method can be applied for quality control of pigeon pea leaves and related medicinal products. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Matrix-assisted laser desorption/ionization mass spectrometric imaging for the rapid segmental analysis of methamphetamine in a single hair using umbelliferone as a matrix.

    PubMed

    Wang, Hang; Wang, Ying

    2017-07-04

    Segmental hair analysis offers a longer period for retrospective drug detection than blood or urine. Hair is a keratinous fiber and is strongly hydrophobic. The embedding of drugs in hydrophobic hair at low concentrations makes it difficult for extraction and detection with matrix-assisted laser desorption/ionization (MALDI) coupled with mass spectrometric imaging (MSI). In this study, a single scalp hair was longitudinally cut with a cryostat section to a length of 4 mm and fixed onto a stainless steel MALDI plate. Umbelliferone was used as a new hydrophobic matrix to enrich and assist the ionization efficiency of methamphetamine in the hair sample. MALDI-Fourier transform ion cyclotron resonance (FTICR)-MS profiling and imaging were performed for direct detection and mapping of methamphetamine on the longitudinal sections of the single hair sample in positive ion mode. Using MALDI-MSI, the distribution of methamphetamine was observed throughout five longitudinally sectioned hair samples from a drug abuser. The changes of methamphetamine were also semi-quantified by comparing the ratios of methamphetamine/internal standard (I.S). This method improves the detection sensitivity of target drugs embedded in a hair matrix for imaging with mass spectrometry. The method could provide a detection level of methamphetamine down to a nanogram per milligram incorporated into hair. The results were also compared with the conventional high performance liquid chromatography -tandem mass spectrometry (HPLC-MS/MS) method. Changes in the imaging results over time by the MSI method showed good semi-quantitative correlation to the results from the HPLC-MS/MS method. This study provides a powerful tool for drug abuse control and forensic medicine analysis in a narrow time frame, and a reduction in the sample amount required. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Validation of a method for the quantitation of ghrelin and unacylated ghrelin by HPLC.

    PubMed

    Staes, Edith; Rozet, Eric; Ucakar, Bernard; Hubert, Philippe; Préat, Véronique

    2010-02-05

    An HPLC/UV method was first optimized for the separation and quantitation of human acylated and unacylated (or des-acyl) ghrelin from aqueous solutions. This method was validated by an original approach using accuracy profiles based on tolerance intervals for the total error measurement. The concentration range that achieved adequate accuracy extended from 1.85 to 59.30microM and 1.93 to 61.60microM for acylated and unacylated ghrelin, respectively. Then, optimal temperature, pH and buffer for sample storage were determined. Unacylated ghrelin was found to be stable in all conditions tested. At 37 degrees C acylated ghrelin was stable at pH 4 but unstable at pH 7.4, the main degradation product was unacylated ghrelin. Finally, this validated HPLC/UV method was used to evaluate the binding of acylated and unacylated ghrelin to liposomes.

  2. Measurement of H2S in vivo and in vitro by the monobromobimane method

    PubMed Central

    Shen, Xinggui; Kolluru, Gopi K.; Yuan, Shuai; Kevil, Christopher

    2015-01-01

    The gasotransmitter hydrogen sulfide (H2S) is known as an important regulator in several physiological and pathological responses. Among the challenges facing the field is the accurate and reliable measurement of hydrogen sulfide bioavailability. We have reported an approach to discretely measure sulfide and sulfide pools using the monobromobimane (MBB) method coupled with RP-HPLC. The method involves the derivatization of sulfide with excess MBB under precise reaction conditions at room temperature to form sulfide-dibimane. The resultant fluorescent sulfide-dibimane (SDB) is analyzed by RP-HPLC using fluorescence detection with the limit of detection for SDB (2 nM). Care must be taken to avoid conditions that may confound H2S measurement with this method. Overall, RP-HPLC with fluorescence detection of SDB is a useful and powerful tool to measure biological sulfide levels. PMID:25725514

  3. Measurement of H2S in vivo and in vitro by the monobromobimane method.

    PubMed

    Shen, Xinggui; Kolluru, Gopi K; Yuan, Shuai; Kevil, Christopher G

    2015-01-01

    The gasotransmitter hydrogen sulfide (H2S) is known as an important regulator in several physiological and pathological responses. Among the challenges facing the field is the accurate and reliable measurement of hydrogen sulfide bioavailability. We have reported an approach to discretely measure sulfide and sulfide pools using the monobromobimane (MBB) method coupled with reversed phase high-performance liquid chromatography (RP-HPLC). The method involves the derivatization of sulfide with excess MBB under precise reaction conditions at room temperature to form sulfide dibimane (SDB). The resultant fluorescent SDB is analyzed by RP-HPLC using fluorescence detection with the limit of detection for SDB (2 nM). Care must be taken to avoid conditions that may confound H2S measurement with this method. Overall, RP-HPLC with fluorescence detection of SDB is a useful and powerful tool to measure biological sulfide levels. © 2015 Elsevier Inc. All rights reserved.

  4. Improved method for the on-line metal chelate affinity chromatography-high-performance liquid chromatographic determination of tetracycline antibiotics in animal products.

    PubMed

    Cooper, A D; Stubbings, G W; Kelly, M; Tarbin, J A; Farrington, W H; Shearer, G

    1998-07-03

    An improved on-line metal chelate affinity chromatography-high-performance liquid chromatography (MCAC-HPLC) method for the determination of tetracycline antibiotics in animal tissues and egg has been developed. Extraction was carried out with ethyl acetate. The extract was then evaporated to dryness and reconstituted in methanol prior to on-line MCAC clean-up and HPLC-UV determination. Recoveries of tetracycline, oxytetracycline, demeclocycline and chlortetracycline in the range 42% to 101% were obtained from egg, poultry, fish and venison tissues spiked at 25 micrograms kg-1. Limits of detection less than 10 microgram kg-1 were estimated for all four analytes. This method has higher throughput, higher recovery and lower limits of detection than a previously reported on-line MCAC-HPLC method which involved aqueous extraction and solid-phase extraction clean-up.

  5. Novel HPLC-UV Method for Simultaneous Determination of Fat-soluble Vitamins and Coenzyme Q10 in Medicines and Supplements.

    PubMed

    Temova-Rakuša, Žane; Srečnik, Eva; Roškar, Robert

    2017-09-01

    A precise, accurate and rapid HPLC-UV method for simultaneous determination of fat-soluble vitamins (vitamin D3, E-acetate, K1, β-carotene, A-palmitate) and coenzyme Q10 was developed and validated according to ICH guidelines. Optimal chromatographic separation of the analytes in minimal analysis time (8 min) was achieved on a Luna C18 150 × 4.6 mm column using a mixture of acetonitrile, tetrahydrofuran and water (50:45:5, v/v/v). The described reversed phase HPLC method is the first published for quantification of these five fat-soluble vitamins and coenzyme Q10 within a single chromatographic run. The method was further applied for quantification of the analytes in selected liquid and solid dosage forms, registered as nutritional supplements and prescription medicines, which confirmed its suitability for routine analysis.

  6. Characterization of nonstarch polysaccharides content from different edible organs of some vegetables, determined by GC and HPLC: comparative study.

    PubMed

    Villanueva-Suárez, M J; Redondo-Cuenca, A; Rodríguez-Sevilla, M D; de las Heras Martínez, M

    2003-09-24

    Content and composition of dietary fiber as nonstarch polysaccharides (NSP) was determined in vegetables belonging to different types of edible organs, using GC and HPLC. Samples analyzed were subterranean organs (radish and leek), leaves (celery, swiss chard, and lettuce), stalks (celery, swiss chard, and asparagus), inflorescence (broccoli), and fruits (tomato, green pepper, and marrow). The results indicate that though the monomeric profile is similar in all these samples quantitative differences were found for neutral sugars and uronic acids among samples of the same type of vegetal organ. The NSP values determined using CG method were in good agreement with HPLC method (R(2) = 0.9005). However, arabinose, mannose, and galactose plus rhamnose are more influenced by the analytical method used than the rest of the monomers in nearly all the samples analyzed. Final values of NSP depend on the method used in celery stalks, broccoli, and green pepper.

  7. Rapid determination of fumonisins in corn-based products by liquid chromatography/tandem mass spectrometry.

    PubMed

    Li, Wei; Herrman, Timothy J; Dai, Susie Y

    2010-01-01

    A simple, fast, and robust method was developed for the determination of fumonisin B1 (FB1), fumonisin B2 (FB2), and fumonisin B3 (FB3) in corn-based human food and animal feed (cornmeal). The method involves a single extraction step followed by centrifugation and filtration before analysis by ultra-performance liquid chromatographylelectrospray ionization (UPLC/ESI)-MS/MS. The LC/MS/MS method developed here represents the fastest and simplest procedure (<30 min) among both conventional HPLC methods and other LC/MS methods using SPE cleanup. The potential for high throughput analysis makes the method particularly beneficial for regulatory agencies and analytical laboratories with a high sample volume. A single-laboratory validation was conducted by testing three different spiking levels (200, 500, and 1000 ng/g for FB1 and FB2; 100, 250, and 500 ng/g for FB3) for accuracy and precision. Recoveries of FB1 ranged from 93 to 98% with RSD values of 3-8%. Recoveries of FB2 ranged from 104 to 108%, with RSD values of 2-6%. Recoveries of FB3 ranged from 94 to 108%, with RSD values of 2-5%.

  8. Evaluation of Tamoxifen and metabolites by LC-MS/MS and HPLC Methods

    PubMed Central

    Heath, D.D.; Flatt, S.W.; Wu, A.H.B.; Pruitt, M.A.; Rock, C.L.

    2015-01-01

    Epidemiological and laboratory evidence suggests that quantification of serum or plasma levels of tamoxifen and the metabolites of tamoxifen, 4-hydroxy-N-desmethyl-tamoxifen (endoxifen), Z-4-hydroxy-tamoxifen (4HT), N-desmethyl-tamoxifen (ND-tam) is a clinically useful tool in the assessment and monitoring of breast cancer status in patients taking adjuvant tamoxifen. A liquid chromatographic mass spectrometric method (LC-MS/MS) was used to measure the blood levels of tamoxifen and the metabolites of tamoxifen. This fully automated analytical method is specific, accurate and sensitive. The LC-MS/MS automated technique has now become a widely accepted reference method. We analyzed a randomly selected batch of blood samples from participants enrolled in a breast cancer study to compare results from this reference method in 40 samples with those obtained from a recently developed high performance liquid chromatography (HPLC) method with fluorescence detection. The mean (SD) concentration for the LC-MS/MS (endoxifen 12.6 [7.5] ng/mL, tamoxifen 105 [44] ng/mL, 4-HT 1.9 [1.0] ng/mL, ND-tam 181 [69] ng/mL) and the HPLC (endoxifen 13.1 [7.8] ng/mL, tamoxifen 108[55]ng/mL, 4-HT 1.8 [0.8] ng/mL, ND-tam 184 [81] ng/mL), the methods did not show any significant differences. Our results confirm that the HPLC method offers an accurate and comparable alternative for the quantification of tamoxifen and tamoxifen metabolites. PMID:24693573

  9. Development of Modern Methods for Determination of Stabilizers in Propellants

    DTIC Science & Technology

    1996-04-01

    powder will! . gtve information Jbout the history of this powder and an indication of its future: usefulness. In othdrs words, the determination of...been excluded in Tables I and II. According to Table I, in order to develop an HPLC method for DPA-stabilized powders , the products that should be... powders were determined by each country using its own HPLC method . The results are given in Table XVI. As indicated, the agreement between the two

  10. Competitive Protein-binding assay-based Enzyme-immunoassay Method, Compared to High-pressure Liquid Chromatography, Has a Very Lower Diagnostic Value to Detect Vitamin D Deficiency in 9–12 Years Children

    PubMed Central

    Zahedi Rad, Maliheh; Neyestani, Tirang Reza; Nikooyeh, Bahareh; Shariatzadeh, Nastaran; Kalayi, Ali; Khalaji, Niloufar; Gharavi, Azam

    2015-01-01

    Background: The most reliable indicator of Vitamin D status is circulating concentration of 25-hydroxycalciferol (25(OH) D) routinely determined by enzyme-immunoassays (EIA) methods. This study was performed to compare commonly used competitive protein-binding assays (CPBA)-based EIA with the gold standard, high-pressure liquid chromatography (HPLC). Methods: Concentrations of 25(OH) D in sera from 257 randomly selected school children aged 9–11 years were determined by two methods of CPBA and HPLC. Results: Mean 25(OH) D concentration was 22 ± 18.8 and 21.9 ± 15.6 nmol/L by CPBA and HPLC, respectively. However, mean 25(OH) D concentrations of the two methods became different after excluding undetectable samples (25.1 ± 18.9 vs. 29 ± 14.5 nmol/L, respectively; P = 0.04). Based on predefined Vitamin D deficiency as 25(OH) D < 12.5 nmol/L, CPBA sensitivity and specificity were 44.2% and 60.6%, respectively, compared to HPLC. In receiver operating characteristic curve analysis, the best cut-offs for CPBA was 5.8 nmol/L, which gave 82% sensitivity, but specificity was 17%. Conclusions: Though CPBA may be used as a screening tool, more reliable methods are needed for diagnostic purposes. PMID:26330983

  11. Demonstration and Evaluation of Solid Phase Microextraction for the Assessment of Bioavailability and Contaminant Mobility. ESTCP Cost and Performance Report

    DTIC Science & Technology

    2012-08-01

    subsequent chemical analysis (into acetonitrile for high-performance liquid chromatography [ HPLC ] analysis or hexane for gas chromatography [GC... analysis ) is rapid and complete. In this work, PAHs were analyzed by Waters 2795 HPLC with fluorescent detection (USEPA Method 8310) and PCBs were...detection limits by direct water injection versus SPME with PDMS and coefficient of variation and correlation coefficient for SPME. Analysis by HPLC

  12. Erroneous HbA1c results in a patient with elevated HbC and HbF.

    PubMed

    Adekanmbi, Joy; Higgins, Trefor; Rodriguez-Capote, Karina; Thomas, Dylan; Winterstein, Jeffrey; Dixon, Tara; Gifford, Jessica L; Krause, Richard; Venner, Allison A; Clarke, Gwen; Estey, Mathew P

    2016-11-01

    HbA1c is used in the diagnosis and monitoring of diabetes mellitus (DM). Interference from hemoglobin variants is a well-described phenomenon, particularly with HPLC-based methods. While immunoassays may generate more reliable HbA1c results in the presence of some variants, these methods are susceptible to negative interference from high concentrations of HbF. We report a case where an accurate HbA1c result could not be obtained by any available method due to the presence of a compound hemoglobinopathy. HbA1c was measured by HPLC, immunoassay, and capillary electrophoresis. Hemoglobinopathy investigation consisted of a CBC, hemoglobin fractionation by HPLC and electrophoresis, and molecular analysis. HbA1c analysis by HPLC and capillary electrophoresis gave no result. Analysis by immunoassay yielded HbA1c results of 5.9% (Siemens DCA 2000+) and 5.1% (Roche Integra), which were inconsistent with other markers of glycemic control. Hemoglobinopathy investigation showed HbC with the hereditary persistence of fetal hemoglobin-2 Ghana deletion. Reliable HbA1c results may be unobtainable in the presence of some hemoglobinopathies. HPLC and capillary electrophoresis alerted the laboratory to the presence of an unusual hemoglobinopathy. Immunoassays generated falsely low results without warning, which could lead to missed diagnoses and under treatment of patients with DM. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. [Determination of rhynchophylline and isorhynchophylline in Uncaria rhynchophylla by HPLC].

    PubMed

    Yang, Xiu-Juan; Hong, Yan-Long; Wu, Fei; Ruan, Ke-Feng; Feng, Yi

    2013-03-01

    To explore an HPLC method for determination of rhnchophylline and isorhnchophylline in Uncaria rhnchophylla. An HPLC method has been developed for determination of rhnchophylline and isorhnchophylline. The transformation of rhnchophylline and isorhnchophylline after heating was also studied by HPLC-ESI-MS. Good linearities of rhynchophylline and isorhynchophylline were 0.064-5.100, 0.064-5.110 mg, respectively. The average recoveries were from 87.51% to 88.83% for rhynchophylline and from 107.9% to 113.9% for isorhynchophylline. The recoveries of rhynchophylline and isorhnchophylline reference solutions after extraction were 12.60% and 40.00% in the reflux extraction procedure, respectively. While in the ultrasonic extraction procedure, the average recoveries of rhynchophylline and isorhynchophylline was from 99.48% to 103.2% and from 97.00% to 99.59%, resepectively. The recoveries of rhynchophylline and isorhnchophylline reference solutions after extraction were 47.08% and 51.03%, respectively. The unqualified recovery could be elucidated by HPLC-ESI-MS analysis, indicating that trhynchophylline could be transformed mostly into isorhynchophylline and a little amount of unkown composition, while isorhynchophylline could be transformed into rhynchophylline isocorynoxeine, corynoxeine and 22-O-beta-D-glucopyranosyl isocorynoxeinic acid during the extraction procedure. Ultrasonic extraction procedure was more sutble for HPLC determination of the content of rhynchophylline and isorhynchophylline in U. rhnchophylla, however, the recovery problems should be paid attention to when it comes to the determination.

  14. Liquid chromatography/Fourier transform IR spectrometry interface flow cell

    DOEpatents

    Johnson, Charles C.; Taylor, Larry T.

    1986-01-01

    A zero dead volume (ZDV) microbore high performance liquid chromatography (.mu.HPLC)/Fourier transform infrared (FTIR) interface flow cell includes an IR transparent crystal having a small diameter bore therein through which a sample liquid is passed. The interface flow cell further includes a metal holder in combination with a pair of inner, compressible seals for directly coupling the thus configured spectrometric flow cell to the outlet of a .mu.HPLC column end fitting to minimize the transfer volume of the effluents exiting the .mu.HPLC column which exhibit excellent flow characteristics due to the essentially unencumbered, open-flow design. The IR beam passes transverse to the sample flow through the circular bore within the IR transparent crystal, which is preferably comprised of potassium bromide (KBr) or calcium fluoride (CaF.sub.2), so as to minimize interference patterns and vignetting encountered in conventional parallel-plate IR cells. The long IR beam pathlength and lensing effect of the circular cross-section of the sample volume in combination with the refractive index differences between the solvent and the transparent crystal serve to focus the IR beam in enhancing sample detection sensitivity by an order of magnitude.

  15. Quantity and quality of secoiridoids and lignans in extra virgin olive oils: the effect of two- and three-way decanters on Leccino and Raggiola olive cultivars.

    PubMed

    Antonini, Elena; Farina, Alfonso; Scarpa, Emanuele Salvatore; Frati, Alessandra; Ninfali, Paolino

    2016-01-01

    In this investigation, 14 extra virgin olive oils (EVOOs), produced with Leccino and Raggiola olive cultivars, by a new two-way (2W) decanter were compared with 14 EVOOs produced by means of a conventional three-way (3W) decanter. The 2W EVOOs had higher phenol concentrations, as shown by high-performance liquid chromatography/diode array detection (HPLC-DAD) analysis and yielded a higher extraction of the 3,4-DHPEA-EDA (oleacein), 3,4-DHPEA-EA (oleuropein aglycone) and p-HPEA-EDA (oleocanthal). The concentrations of lignans, (+)-pinoresinol and (+)-1-acetoxypinoresinol, detected by HPLC-FLD equipment, were higher in the 2W EVOOs than they were in EVOOs produced using the 3W system. Total phenols, detected by the Folin-Ciocalteu assay, were lower than those obtained by HPLC, but they significantly correlated (p < 0.05). The antioxidant capacity (ORAC) values of 2W EVOOs were higher than those of 3W EVOOs. In conclusion, the 2W system provided high-quality phenol EVOOs and became an indispensable tool when adverse climatic conditions reduced the olive secoiridoid concentration.

  16. Liquid chromatography/Fourier transform IR spectrometry interface flow cell

    DOEpatents

    Johnson, C.C.; Taylor, L.T.

    1985-01-04

    A zero dead volume (ZDV) microbore high performance liquid chromatography (..mu.. HPLC)/Fourier transform infrared (FTIR) interface flow cell includes an IR transparent crystal having a small diameter bore therein through which a sample liquid is passed. The interface flow cell further includes a metal holder in combination with a pair of inner, compressible seals for directly coupling the thus configured spectrometric flow cell to the outlet of a ..mu.. HPLC column end fitting to minimize the transfer volume of the effluents exiting the ..mu.. HPLC column which exhibit excellent flow characteristics due to the essentially unencumbered, open-flow design. The IR beam passes transverse to the sample flow through the circular bore within the IR transparent crystal, which is preferably comprised of potassium bromide (KBr) or calcium fluoride (CaF/sub 2/), so as to minimize interference patterns and vignetting encountered in conventional parallel-plate IR cells. The long IR beam pathlength and lensing effect of the circular cross-section of the sample volume in combination with the refractive index differences between the solvent and the transparent crystal serve to focus the IR beam in enhancing sample detection sensitivity by an order of magnitude.

  17. Identification of phenanthrene derivatives in Aerides rosea (Orchidaceae) using the combined systems HPLC-ESI-HRMS/MS and HPLC-DAD-MS-SPE-UV-NMR.

    PubMed

    Cakova, Veronika; Urbain, Aurélie; Antheaume, Cyril; Rimlinger, Nicole; Wehrung, Patrick; Bonté, Frédéric; Lobstein, Annelise

    2015-01-01

    In our continued efforts to contribute to the general knowledge on the chemical diversity of orchids, we have decided to focus our investigations on the Aeridinae subtribe. Following our previous phytochemical study of Vanda coerulea, which has led to the identification of phenanthrene derivatives, a closely related species, Aerides rosea Lodd. ex Lindl. & Paxton, was chosen for investigation. To identify new secondary metabolites, and to avoid isolation of those already known, by means of the combined systems HPLC-DAD(diode-array detector) with high-resolution tandem mass spectrometry (HRMS/MS) and HPLC-DAD-MS-SPE(solid-phase extraction)-UV-NMR. A dereplication strategy was developed using a HPLC-DAD-HRMS/MS targeted method and applied to fractions from A. rosea stem extract. Characterisation of unknown minor compounds was then performed using the combined HPLC-DAD-MS-SPE-UV-NMR system. The dereplication method allowed the characterisation of four compounds (gigantol, imbricatin, methoxycoelonin and coelonin), previously isolated from Vanda coerulea stem extract. The analyses of two fractions permitted the identification of five additional minor constituents including one phenanthropyran, two phenanthrene and two dihydrophenanthrene derivatives. The full set of NMR data of each compound was obtained from microgram quantities. Nine secondary metabolites were characterised in A. rosea stems, utilising HPLC systems combined with high-resolution analytical systems. Two of them are newly described phenanthrene derivatives: aerosanthrene (5-methoxyphenanthrene-2,3,7-triol) and aerosin (3-methoxy-9,10-dihydro-2,5,7-phenanthrenetriol). Copyright © 2014 John Wiley & Sons, Ltd.

  18. Fluorescent adduct formation with terbium: a novel strategy for transferrin glycoform identification in human body fluids and carbohydrate-deficient transferrin HPLC method validation.

    PubMed

    Sorio, Daniela; De Palo, Elio Franco; Bertaso, Anna; Bortolotti, Federica; Tagliaro, Franco

    2017-02-01

    This paper puts forward a new method for the transferrin (Tf) glycoform analysis in body fluids that involves the formation of a transferrin-terbium fluorescent adduct (TfFluo). The key idea is to validate the analytical procedure for carbohydrate-deficient transferrin (CDT), a traditional biochemical serum marker to identify chronic alcohol abuse. Terbium added to a human body-fluid sample produced TfFluo. Anion exchange HPLC technique, with fluorescence detection (λ exc 298 nm and λ em 550 nm), permitted clear separation and identification of Tf glycoform peaks without any interfering signals, allowing selective Tf sialoforms analysis in human serum and body fluids (cadaveric blood, cerebrospinal fluid, and dried blood spots) hampered for routine test. Serum samples (n = 78) were analyzed by both traditional absorbance (Abs) and fluorescence (Fl) HPLC methods and CDT% levels demonstrated a significant correlation (p < 0.001 Pearson). Intra- and inter-runs CV% was 3.1 and 4.6%, respectively. The cut-off of 1.9 CDT%, related to the HPLC Abs proposed as the reference method, by interpolation in the correlation curve with the present method demonstrated a 1.3 CDT% cut-off. Method comparison by Passing-Bablok and Bland-Altman tests demonstrated Fl versus Abs agreement. In conclusion, the novel method is a reliable test for CDT% analysis and provides a substantial analytical improvement offering important advantages in terms of types of body fluid analysis. Its sensitivity and absence of interferences extend clinical applications being reliable for CDT assay on body fluids usually not suitable for routine test. Graphical Abstract The formation of a transferrin-terbium fluorescent adduct can be used to analyze the transferrin glycoforms. The HPLC method for carbohydrate-deficient transferrin (CDT%) measurement was validated and employed to determine the levels in different body fluids.

  19. Methacrylate-bonded covalent-organic framework monolithic columns for high performance liquid chromatography.

    PubMed

    Liu, Li-Hua; Yang, Cheng-Xiong; Yan, Xiu-Ping

    2017-01-06

    Covalent-organic frameworks (COFs) are a newfangled class of intriguing microporous materials. Considering their unique properties, COFs should be promising as packing materials for high performance liquid chromatography (HPLC). However, the irregular shape and sub-micrometer size of COFs synthesized via the traditional methods render the main obstacles for the application of COFs in HPLC. Herein, we report the preparation of methacrylate-bonded COF monolithic columns for HPLC to overcome the above obstacles. The prepared COF bonded monolithic columns not only show good homogeneity and permeability, but also give high column efficiency, good resolution and precision for HPLC separation of small molecules including polycyclic aromatic hydrocarbons, phenols, anilines, nonsteroidal anti-inflammatory drugs and benzothiophenes. Compared with the bare polymer monolithic column, the COF bonded monolithic columns show enhanced hydrophobic, π-π and hydrogen bond interactions in reverse phase HPLC. The results reveal the great potential of COF bonded monoliths for HPLC and COFs in separation sciences. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Updated folate data in the Dutch Food Composition Database and implications for intake estimates

    PubMed Central

    Westenbrink, Susanne; Jansen-van der Vliet, Martine; van Rossum, Caroline

    2012-01-01

    Background and objective Nutrient values are influenced by the analytical method used. Food folate measured by high performance liquid chromatography (HPLC) or by microbiological assay (MA) yield different results, with in general higher results from MA than from HPLC. This leads to the question of how to deal with different analytical methods in compiling standardised and internationally comparable food composition databases? A recent inventory on folate in European food composition databases indicated that currently MA is more widely used than HPCL. Since older Dutch values are produced by HPLC and newer values by MA, analytical methods and procedures for compiling folate data in the Dutch Food Composition Database (NEVO) were reconsidered and folate values were updated. This article describes the impact of this revision of folate values in the NEVO database as well as the expected impact on the folate intake assessment in the Dutch National Food Consumption Survey (DNFCS). Design The folate values were revised by replacing HPLC with MA values from recent Dutch analyses. Previously MA folate values taken from foreign food composition tables had been recalculated to the HPLC level, assuming a 27% lower value from HPLC analyses. These recalculated values were replaced by the original MA values. Dutch HPLC and MA values were compared to each other. Folate intake was assessed for a subgroup within the DNFCS to estimate the impact of the update. Results In the updated NEVO database nearly all folate values were produced by MA or derived from MA values which resulted in an average increase of 24%. The median habitual folate intake in young children was increased by 11–15% using the updated folate values. Conclusion The current approach for folate in NEVO resulted in more transparency in data production and documentation and higher comparability among European databases. Results of food consumption surveys are expected to show higher folate intakes when using the updated values. PMID:22481900

  1. Detection, characterization and identification of phenolic acids in Danshen using high-performance liquid chromatography with diode array detection and electrospray ionization mass spectrometry.

    PubMed

    Liu, Ai-Hua; Guo, Hui; Ye, Min; Lin, Yan-Hua; Sun, Jiang-Hao; Xu, Man; Guo, De-An

    2007-08-17

    By using HPLC-diode array detection-electrospray ion trap tandem mass spectrometry (HPLC-DAD-ESI-MS(n)) in negative ion mode, we have analyzed the fragmentation pathways of 11 phenolic acids which were isolated from Danshen. Then the extract of Danshen was analyzed, and a total of 42 phenolic acids, including sixteen new minor constituents, were identified or tentatively identified for the first time. A new solid-phase extraction (SPE) method, new HPLC separation method, new liquid chromatography (LC)-MS and LC-MS(n) (n=3-5) data and proposed fragmentation pathways, LC retention time for phenolic acids are reported.

  2. Analysis and identification of astaxanthin and its carotenoid precursors from Xanthophyllomyces dendrorhous by high-performance liquid chromatography.

    PubMed

    Lu, Mingbo; Zhang, Yang'e; Zhao, Chunfang; Zhou, Pengpeng; Yu, Longjiang

    2010-01-01

    This study presents an HPLC method for simultaneous analysis of astaxanthin and its carotenoid precursors from Xanthophyllomyces dendrorhous. The HPLC method is accomplished by employing a C18 column and the mobile phase methanol/water/acetonitrile/ dichloromethane (70:4:13:13, v/v/v/v). Astaxanthin is quantified by detection at 480 nm. The carotenoid precursors are identified by LC-APCI-MS and UV-vis absorption spectra. Peaks showed in the HPLC chromatogram are identified as carotenoids in the monocyclic biosynthetic pathway or their derivatives. In the monocyclic carotenoid pathway, 3,3'-dihydroxy-beta,psi-carotene-4,4'-dione (DCD) is produced through gamma-carotene and torulene.

  3. [Sensitive and selective HPLC methods with prechromatographic derivatization for the determination of cyclamate in foods].

    PubMed

    Rüter, J; Raczek, D I

    1992-06-01

    A sensitive and selective high pressure liquid chromatography (HPLC) procedure for the determination of sodium cyclamate in juices and preserves is presented. The method depends on the oxidation of cyclamate to cyclohexylamine, which then is converted prechromatographically into a fluorescent derivative. It is analyzed by HPLC on a C18:reversed-phase column and determined with fluorescence detection (excitation at 350 nm, emission at 440-650 nm). The detection limit of sodium cyclamate was 0.5-5 mg/kg, depending on the nature and dilution of the samples. The relative standard deviations thus obtained were +/- 1.0 to +/- 2.6%. The average recovery was 90%.

  4. Dipeptide Sequence Determination: Analyzing Phenylthiohydantoin Amino Acids by HPLC

    NASA Astrophysics Data System (ADS)

    Barton, Janice S.; Tang, Chung-Fei; Reed, Steven S.

    2000-02-01

    Amino acid composition and sequence determination, important techniques for characterizing peptides and proteins, are essential for predicting conformation and studying sequence alignment. This experiment presents improved, fundamental methods of sequence analysis for an upper-division biochemistry laboratory. Working in pairs, students use the Edman reagent to prepare phenylthiohydantoin derivatives of amino acids for determination of the sequence of an unknown dipeptide. With a single HPLC technique, students identify both the N-terminal amino acid and the composition of the dipeptide. This method yields good precision of retention times and allows use of a broad range of amino acids as components of the dipeptide. Students learn fundamental principles and techniques of sequence analysis and HPLC.

  5. Parallel microscope-based fluorescence, absorbance and time-of-flight mass spectrometry detection for high performance liquid chromatography and determination of glucosamine in urine.

    PubMed

    Xiong, Bo; Wang, Ling-Ling; Li, Qiong; Nie, Yu-Ting; Cheng, Shuang-Shuang; Zhang, Hui; Sun, Ren-Qiang; Wang, Yu-Jiao; Zhou, Hong-Bin

    2015-11-01

    A parallel microscope-based laser-induced fluorescence (LIF), ultraviolet-visible absorbance (UV) and time-of-flight mass spectrometry (TOF-MS) detection for high performance liquid chromatography (HPLC) was achieved and used to determine glucosamine in urines. First, a reliable and convenient LIF detection was developed based on an inverted microscope and corresponding modulations. Parallel HPLC-LIF/UV/TOF-MS detection was developed by the combination of preceding Microscope-based LIF detection and HPLC coupled with UV and TOF-MS. The proposed setup, due to its parallel scheme, was free of the influence from photo bleaching in LIF detection. Rhodamine B, glutamic acid and glucosamine have been determined to evaluate its performance. Moreover, the proposed strategy was used to determine the glucosamine in urines, and subsequent results suggested that glucosamine, which was widely used in the prevention of the bone arthritis, was metabolized to urines within 4h. Furthermore, its concentration in urines decreased to 5.4mM at 12h. Efficient glucosamine detection was achieved based on a sensitive quantification (LIF), a universal detection (UV) and structural characterizations (TOF-MS). This application indicated that the proposed strategy was sensitive, universal and versatile, and it was capable of improved analysis, especially for analytes with low concentrations in complex samples, compared with conventional HPLC-UV/TOF-MS. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Comparison of UV spectrophotometry and high performance liquid chromatography methods for the determination of repaglinide in tablets

    PubMed Central

    Dhole, Seema M.; Khedekar, Pramod B.; Amnerkar, Nikhil D.

    2012-01-01

    Background: Repaglinide is a miglitinide class of antidiabetic drug used for the treatment of type 2 diabetes mellitus. A fast and reliable method for the determination of repaglinide was highly desirable to support formulation screening and quality control. Objective: UV spectrophotometric and reversed-phase high performance liquid chromatography (RP-HPLC) methods were developed for determination of repaglinide in the tablet dosage form. Materials and Methods: The UV spectrum recorded between 200 400 nm using methanol as solvent and the wavelength 241 nm was selected for the determination of repaglinide. RP-HPLC analysis was carried out using Agilent TC-C18 (2) column and mobile phase composed of methanol and water (80:20 v/v, pH adjusted to 3.5 with orthophosphoric acid) at a flow rate of 1.0 ml/min. Parameters such as linearity, precision, accuracy, recovery, specificity and ruggedness are studied as reported in the International Conference on Harmonization (ICH) guidelines. Results: The developed methods illustrated excellent linearity (r2 > 0.999) in the concentration range of 5-30 μg/ml and 5-50 μg/ml for UV spectrophotometric and HPLC methods, respectively. Precision (%R.S.D < 1.50) and mean recoveries were found in the range of 99.63-100.45% for UV spectrophotometric method and 99.71-100.25% for HPLC method which shows accuracy of the methods. Conclusion: The developed methods were found to be reliable, simple, fast, accurate and successfully used for the quality control of repaglinide as a bulk drug and in pharmaceutical formulations. PMID:23781481

  7. Preparation of a zeolite-modified polymer monolith for identification of synthetic colorants in lipsticks

    NASA Astrophysics Data System (ADS)

    Wang, Huiqi; Li, Zheng; Niu, Qian; Ma, Jiutong; Jia, Qiong

    2015-10-01

    A novel zeolite-modified poly(methacrylic acid-ethylenedimethacrylate) (zeolite@poly(MAA-EDMA)) monolithic column was prepared with the in situ polymerization method and employed in polymer monolith microextraction for the separation and preconcentration of synthetic colorants combined with high performance liquid chromatography. The polymer was characterized by scanning electronmicroscopy, Fourier-transform infrared spectroscopy, X-ray photoelectron spectroscopy, and thermo-gravimetric analysis. Various parameters affecting the extraction efficiency were investigated and optimized. Under the optimum experimental conditions, we obtained acceptable linearities, low limits of detection, and good intra-day/inter-day relative standard deviations. The method was applied to the determination of synthetic colorants in lipsticks with recoveries ranged from 70.7% to 109.7%. Compared with conventional methacrylic acid-based monoliths, the developed monolith exhibited high enrichment capacity because of the introduction of zeolites into the preparation process. The extraction efficiency followed the order: zeolite@poly(MAA-EDMA) > poly(MAA-EDMA) > direct HPLC analysis.

  8. Microbial degradation of microcystin in Florida’s freshwaters

    PubMed Central

    Ramani, A.; Rein, K.; Shetty, K. G.

    2012-01-01

    Presence of microcystin (MC), a predominant freshwater algal toxin and a suspected liver carcinogen, in Florida’s freshwaters poses serious health threat to humans and aquatic species. Being recalcitrant to conventional physical and chemical water treatment methods, biological methods of MC removal is widely researched. Water samples collected from five sites of Lake Okeechobee (LO) frequently exposed to toxic Microcystis blooms were used as inoculum for enrichment with microcystin LR (MC-LR) supplied as sole C and N source. After 20 days incubation, MC levels were analyzed using high performance liquid chromatography (HPLC). A bacterial consortium consisting of two isolates DC7 and DC8 from the Indian Prairie Canal sample showed over 74% toxin degradation at the end of day 20. Optimal temperature requirement for biodegradation was identified and phosphorus levels did not affect the MC biodegradation. Based on 16S rRNA sequence similarity the isolate DC8 was found to have a match with Microbacterium sp. and the DC7 isolate with Rhizobium gallicum (AY972457). PMID:21611743

  9. Determination of blood sirolimus concentrations in liver and kidney transplant recipients using the Innofluor® fluorescence polarization immunoassay: Comparison with the microparticle enzyme immunoassay and high-performance liquid chromatography-ultraviolet method

    PubMed Central

    Bouzas, Lorena; Hermida, Jesús

    2009-01-01

    Background Although high-performance liquid chromatography (HPLC) is the method of choice for blood sirolimus determination, the microparticle enzyme immunoassay (MEIA) run on the IMx® analyser is widely used in therapeutic monitoring of this immunosuppressant agent. The aim of our study was to evaluate the possible determination of sirolimus using the fluorescence polarization immunoassay (FPIA) commercialized for everolimus quantification. Methods Sirolimus concentrations were determined in whole-blood samples from liver and kidney transplant recipients using the Innofluor® Certican® FPIA (Seradyn Inc.) run on a TDx® analyser (Abbott Laboratories), Sirolimus MEIA run on an IMx® analyser (Abbott Laboratories), and HPLC (UV detection) methods. Results The Innofluor® FPIA has a similar cross-reactivity with everolimus and sirolimus, and the within- and between-run coefficients of variation obtained for sirolimus determination were 2.7%–13.3%. In analysing different blood samples from liver and kidney transplant patients the linear regressions obtained were: FPIA = 1.12 HPLC + 0.43 (n=104, r=0.874), MEIA = 1.14 HPLC (n=146, r=0.892), and FPIA = 1.00 MEIA + 0.29 (n=106, r=0.941). Better correlation coefficients were obtained between the methods in the liver transplant samples (r≥0.900) than in the kidney transplant samples (r≥0.849). No significant effect was found for sirolimus clearance or the blood hematocrit on the relationship between the results produced by both immunoassays and HPLC. Conclusion The Innofluor® FPIA is a valid alternative with an analogous performance to the MEIA for the therapeutic monitoring of sirolimus. PMID:19242874

  10. HPLC determination of cefprozil in tablets using monolithic and C18 silica columns.

    PubMed

    Can, Nafiz O

    2011-08-01

    Cefprozil (CPZ) is a second-generation semi-synthetic cephalosporin antibiotic that commonly exists as the mixture of Z and E diastereoisomers, at the ratio of approximately 9:1. A novel reversed-phase HPLC method for the determination of CPZ in tablets was described. The separation of CPZ diastereoisomers and caffeine (internal standard) was carried out by applying the same analytical and instrumental conditions on two stationary phases, which have different surface chemistries. The columns used in the study were monolithic silica Merck Chromolith Performance RP-18e and conventional C18 silica Phenomenex Synergi Hydro RP columns. In total, 10 μL aliquots of samples were injected into the system and eluted using water-acetonitrile (90:10, v/v) solution, which was pumped through the column at a flow rate of 1.0 mL/min. The analyte peaks were detected at 200 nm using diode array detector with high specificity. CPZ diastereoisomers and caffeine were measured within 13 min using the C18 column, whereas <5 min was required for the monolithic one. Validation studies were performed according to official recommendations. Value of a monolithic column for the assay of diastereoisomers in pharmaceutical tablets was evaluated for the first time and found as a powerful alternative to highly efficient C18 columns. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Structural characterization of constituents with molecular diversity in fractions from Lysidice brevicalyx by liquid chromatography/diode-array detection/electrospray ionization tandem mass spectrometry and liquid chromatography/nuclear magnetic resonance.

    PubMed

    Qu, Jing; Hu, You-cai; Li, Jian-bei; Wang, Ying-hong; Zhang, Jin-lan; Abliz, Zeper; Yu, Shi-shan; Liu, Yun-bao

    2008-01-01

    A combination of electrospray ionization tandem mass spectrometry with high-performance liquid chromatography (HPLC/ESI-MSn), and hyphenation of liquid chromatography to nuclear magnetic resonance spectroscopy (HPLC/NMR), have been extensively utilized for on-line analysis of natural products, analyzing metabolite and drug impurity. In our last paper, we reported an on-line analytical method for structural identification of trace alkaloids in the same class. However, the structural types of the constituents in plants were various, such as flavanoids, terpenoids and steroids. It is important to establish an effective analytical method for on-line structural identification of constituents with molecular diversity in extracts of plants. So, in the present study, the fragmentation patterns of some isolated stilbenes, phloroglucinols and flavanoids from Lysidice rhodostegia were investigated by ESI-MSn. Their fragmentation rules and UV characteristics are summarized, and the relationship between the spectral characteristics, rules and the structures is described. According to the fragmentation rules, NMR and UV spectral characteristics, 24 constituents of different types in the fractions from L. brevicalyx of the same genus were structurally characterized on the basis of HPLC/HRMS, HPLC-UV/ESI-MSn, HPLC/1H NMR and HPLC/1H-1H COSY rapidly. Of these, six (10, 13, 14, 16, 17 and 23) are new compounds and all of them are reported from L. brevicalyx for the first time. The aim is to develop an effective analytical method for on-line structural identification of natural products with molecular diversity in plants, and to guide the rapid and direct isolation of novel compounds by chemical screening.

  12. Direct determination of neonicotinoid insecticides in an analytically challenging crop such as Chinese chives using selective ELISAs.

    PubMed

    Watanabe, Eiki; Miyake, Shiro

    2018-06-05

    Easy-to-use commercial kit-based enzyme-linked immunosorbent assays (ELISAs) have been used to detect neonicotinoid dinotefuran, clothianidin and imidacloprid in Chinese chives, which are considered a troublesome matrix for chromatographic techniques. Based on their high water solubility, water was used as an extractant. Matrix interference could be avoided substantially just diluting sample extracts. Average recoveries of insecticides from spiked samples were 85-113%, with relative standard deviation of <15%. The concentrations of insecticides detected from the spiked samples with the proposed ELISA methods correlated well with those by the reference high-performance liquid chromatography (HPLC) method. The residues analyzed by the ELISA methods were consistently 1.24 times that found by the HPLC method, attributable to loss of analyte during sample clean-up for HPLC analyses. It was revealed that the ELISA methods can be applied easily to pesticide residue analysis in troublesome matrix such as Chinese chives.

  13. Development of a Thiolysis HPLC Method for the Analysis of Procyanidins in Cranberry Products.

    PubMed

    Gao, Chi; Cunningham, David G; Liu, Haiyan; Khoo, Christina; Gu, Liwei

    2018-03-07

    The objective of this study was to develop a thiolysis HPLC method to quantify total procyanidins, the ratio of A-type linkages, and A-type procyanidin equivalents in cranberry products. Cysteamine was utilized as a low-odor substitute of toluene-α-thiol for thiolysis depolymerization. A reaction temperature of 70 °C and reaction time of 20 min, in 0.3 M of HCl, were determined to be optimum depolymerization conditions. Thiolytic products of cranberry procyanidins were separated by RP-HPLC and identified using high-resolution mass spectrometry. Standards curves of good linearity were obtained on thiolyzed procyanidin dimer A2 and B2 external standards. The detection and quantification limits, recovery, and precision of this method were validated. The new method was applied to quantitate total procyanidins, average degree of polymerization, ratio of A-type linkages, and A-type procyanidin equivalents in cranberry products. Results showed that the method was suitable for quantitative and qualitative analysis of procyanidins in cranberry products.

  14. Separation of aromatic carboxylic acids using quaternary ammonium salts on reversed-phase HPLC. 2. Application for the analysis of Loy Yang coal oxidation products

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawamura, K.; Okuwaki, A.; Verheyen, T.V.

    In order to develop separation processes and analytical methods for aromatic carboxylic acids for the coal oxidation products, the separation behavior of aromatic carboxylic acids on a reversed-phase HPLC using eluent containing quaternary ammonium salt was optimized using the solvent gradient method. This method was applied for the analysis of Loy Yang coal oxidation products. It was confirmed that the analytical data using this method were consistent with those determined using gas chromatography.

  15. Stir bar sorptive extraction combined with high performance liquid chromatography-ultraviolet/inductively coupled plasma mass spectrometry for analysis of thyroxine in urine samples.

    PubMed

    Fan, Wenying; Mao, Xiangju; He, Man; Chen, Beibei; Hu, Bin

    2013-11-29

    tIn this work, polyethyleneglycol (PEG)/hydroxyl polydimethylsiloxane (OH-PDMS)/γ -mercaptopropyltrimethoxysilane (γ -MPTS) coated stir bar was prepared by sol–gel process and its extraction performance for the extraction of amphoteric thyroxines (3,3',5,5'-tetraiodothyronin, T(4); 3,3',5-triiodothyronine, T(3); reversed-3,3',5-triiodothyronine, rT(3)) and their metabolite (3,5-diiodothyronine,T2) was studied. The preparation reproducibility of PEG/OH-PDMS/γ -MPTS coated stir bar was investigated, and the relative standard deviations (RSDs) in the same batch and among different batches were 3.3–14.3% (n = 5) and 7.7–16.6% (n = 3), respectively. The prepared PEG/OH-PDMS/γ -MPTS coated stir bar could be reused for more than 20 times. Based on this fact, a novel method of stir bar sorptive extraction (SBSE) combined with high performance liquid chromatography (HPLC)-ultraviolet (UV)and HPLC-inductively coupled plasma mass spectrometry (ICP-MS) for the analysis of target thyroxinesin human urine samples was developed. The influencing factors of SBSE, such as sample pH, extraction time, stirring rate, salt effect, desorption solution and desorption time, were studied in detail, and the analytical performance of the proposed method was evaluated under the optimized conditions. The enrichment factors (EFs) of the developed method for four target thyroxines were in the range of 14.9–70.4(theoretical enrichment factor was 100). The RSDs were ranging from 4.0% to 13.8% for SBSE-HPLC-UV (c = 25 μg/L, n = 6) and from 3.7% to 6.1% for SBSE-HPLC-ICP-MS (c = 0.5 μg/L, n = 5). The linear range obtained by SBSE-HPLC-UV was 2–500 μg/L for T(2)and 5–500 μg/L for rT3, T(3)and T(4), with correlation coefficients (r) ranging from 0.9957 to 0.9998, respectively, while the linear range obtained by SBSE-HPLC-ICP-MS was 0.05–500 μg/L for T(2) and rT(3), 0.10–200 μg/L for T(3) and 0.05–200 μg/L for T(4)with r ranging from 0.9979 to 0.9998, respectively. The limits of detection (LODs) for the target thyroxines were 0.60–2.20 μg/L for SBSE-HPLC-UV and 0.0071–0.0355 μg/L SBSE-HPLC-ICP-MS, respectively. The developed method was applied for the determination of target thyroxines in urine samples, and the recovery for the spiking samples obtained by SBSE-HPLC-UV was in the range of 81.6–137.6% for human urine,while the recovery for the spiking urine samples obtained by SBSE-HPLC-ICP-MS were in the range of 72.0–121.5%.

  16. Qualitative and quantitative determination of yohimbine in authentic yohimbe bark and in commercial aphrodisiacs by HPLC-UV-API/ MS methods.

    PubMed

    Zanolari, Boris; Ndjoko, Karine; Ioset, Jean-Robert; Marston, Andrew; Hostettmann, Kurt

    2003-01-01

    The development and validation of a rapid qualitative and quantitative method based on an HPLC-UV-MS technique with atmospheric pressure chemical ionisation and electrospray ionisation for the analysis of yohimbine in a number of commercial aphrodisiac products is reported. HPLC with multiple-stage mass spectrometry experiments allowed the identification of the target compound and increased the selectivity of complex analyses such as those involved with multi-botanical preparations. The precision and the robustness of the method were improved by the use of two internal standards: codeine for UV detection and deuterium-labelled yohimbine for MS detection. Twenty commercial aphrodisiac preparations were analysed and the amount of yohimbine measured and expressed as the maximal dose per day suggested on product labels ranged from 1.32 to 23.16 mg.

  17. Comparison of UV spectrophotometry and high performance liquid chromatography methods for the determination of repaglinide in tablets.

    PubMed

    Dhole, Seema M; Khedekar, Pramod B; Amnerkar, Nikhil D

    2012-07-01

    Repaglinide is a miglitinide class of antidiabetic drug used for the treatment of type 2 diabetes mellitus. A fast and reliable method for the determination of repaglinide was highly desirable to support formulation screening and quality control. UV spectrophotometric and reversed-phase high performance liquid chromatography (RP-HPLC) methods were developed for determination of repaglinide in the tablet dosage form. The UV spectrum recorded between 200 400 nm using methanol as solvent and the wavelength 241 nm was selected for the determination of repaglinide. RP-HPLC analysis was carried out using Agilent TC-C18 (2) column and mobile phase composed of methanol and water (80:20 v/v, pH adjusted to 3.5 with orthophosphoric acid) at a flow rate of 1.0 ml/min. Parameters such as linearity, precision, accuracy, recovery, specificity and ruggedness are studied as reported in the International Conference on Harmonization (ICH) guidelines. The developed methods illustrated excellent linearity (r(2) > 0.999) in the concentration range of 5-30 μg/ml and 5-50 μg/ml for UV spectrophotometric and HPLC methods, respectively. Precision (%R.S.D < 1.50) and mean recoveries were found in the range of 99.63-100.45% for UV spectrophotometric method and 99.71-100.25% for HPLC method which shows accuracy of the methods. The developed methods were found to be reliable, simple, fast, accurate and successfully used for the quality control of repaglinide as a bulk drug and in pharmaceutical formulations.

  18. MOF-5(Zn)-Fe2O4 nanocomposite based magnetic solid-phase microextraction followed by HPLC-UV for efficient enrichment of colchicine in root of colchicium extracts and plasma samples.

    PubMed

    Bahrani, Sonia; Ghaedi, Mehrorang; Dashtian, Kheibar; Ostovan, Abbas; Mansoorkhani, Mohammad Javad Khoshnood; Salehi, Amin

    2017-11-01

    In present work, facile method is developed for determination of colchicine in human plasma sample, autumn and spring root of colchicium extracts by ultrasound assisted dispersive magnetic solid phase microextraction followed by HPLC-UV method (UAD-MSPME-HPLC-UV). Magnetic (Fe 2 O 4 -nanoparticles) metal organic framework-5, (MOF-5(Zn)-Fe 2 O 4 NPs) was synthesized by dispersing MOF-5 and Fe(NO 3 ) 3 .9H 2 O in ethylene glycol (as capping agent) and NaOH (pH adjustment agent) by hydrothermal method. The prepared sorbent was characterized via XRD and SEM analysis and applied as magnetic solid phase in UAD-MSPME-HPLC-UV method. In this method, colchicine molecules were sorbed on MOF-5(Zn)-Fe 2 O 4 NPs sorbent by various mechanisms like ion exchange, hydrogen bonding and electrostatic, ᴨ-ᴨ, hard-hard and dipole-ion interaction followed by exposing sonication waves as incremental mass transfer agent and then the sorbent was separated from the sample matrix by an external magnetic fields. Subsequently, accumulated colchicine were eluted by small volume of desorption organic solvent. Influence of operational variables such as MOF-5(Zn)-Fe 2 O 4 NPs mass, volume of extracting solvent and sonication time on response property (recovery) were studied and optimized by central composite design (CCD) combined with desirability function (DF) approach. Under optimum condition, the method has wide linear calibration rang (0.5-1700ngmL -1 ) with reasonable detection limit (0.13ngmL -1 ) and R 2 =0.9971. Finally, the UAD-MSPME-HPLC-UV method was successfully applied for determination of colchicine autumn and spring root of colchicium extracts and plasma samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. First derivative ratio spectrophotometric, HPTLC-densitometric, and HPLC determination of nicergoline in presence of its hydrolysis-induced degradation product.

    PubMed

    Ahmad, Abdel Kader S; Kawy, M Abdel; Nebsen, M

    2002-10-15

    Three methods are presented for the determination of Nicergoline in presence of its hydrolysis-induced degradation product. The first method was based on measurement of the first derivative of ratio spectra amplitude of Nicergoline at 291 nm. The second method was based on separation of Nicergoline from its degradation product followed by densitometric measurement of the spots at 287 nm. The separation was carried out on HPTLC silica gel F(254) plates, using methanol-ethyl acetate-glacial acetic acid (5:7:3, v/v/v) as mobile phase. The third method was based on high performance liquid chromatographic (HPLC) separation and determination of Nicergoline from its degradation product on a reversed phase, nucloesil C(18) column using a mobile phase of methanol-water-glacial acetic acid (80:20:0.1, v/v/v) with UV detection at 280 nm. Chlorpromazine hydrochloride was used as internal standard. Laboratory prepared mixtures containing different percentages of the degradation product were analysed by the proposed methods and satisfactory results were obtained. These methods have been successfully applied to the analysis of Nicergoline in Sermion tablets. The validities of these methods were ascertained by applying standard addition technique, the mean percentage recovery +/- R.S.D.% was found to be 99.47 +/- 0.752, 100.01 +/- 0.940, 99.75 +/- 0.740 for the first derivative of ratio spectra method, the HPTLC method and the HPLC method, respectively. The proposed methods were statistically compared with the manufacturer's HPLC method of analysis of Nicergoline and no significant difference was found with respect to both precision and accuracy. They have the advantage of being stability indicating. Therefore, they can be used for routine analysis of the drug in quality control laboratories. Copyright 2002 Elsevier Science B.V.

  20. The integrated quality assessment of Chinese commercial dry red wine based on a method of online HPLC-DAD-CL combined with HPLC-ESI-MS.

    PubMed

    Yu, Hai-Xiang; Sun, Li-Qiong; Qi, Jin

    2014-07-01

    To apply an integrated quality assessment strategy to investigate the quality of multiple Chinese commercial dry red wine samples. A comprehensive method was developed by combining a high performance liquid chromatography-diode array detector-chemiluminescence (HPLC-DAD-CL) online hyphenated system with an HPLC-ESI-MS technique. Chromatographic and H2O2-scavenging active fingerprints of thirteen batches of different, commercially available Chinese dry red wine samples were obtained and analyzed. Twenty-five compounds, including eighteen antioxidants were identified and evaluated. The dominant and characteristic antioxidants in the samples were identified. The relationships between antioxidant potency and the cultivated variety of grape, producing area, cellaring period, and trade mark are also discussed. The results provide the feasibility for an integrated quality assessment strategy to be efficiently and objectively used in quality (especially antioxidant activity) assessment and identification of dry red wine. Copyright © 2014 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  1. Simultaneous determination of bioactive constituents in Danggui Buxue Tang for quality control by HPLC coupled with a diode array detector, an evaporative light scattering detector and mass spectrometry.

    PubMed

    Yi, Ling; Qi, Lian-Wen; Li, Ping; Ma, Yi-Han; Luo, Yong-Jing; Li, Hai-Yun

    2007-09-01

    Danggui Buxue Tang (DBT), a classical traditional Chinese formula comprising Radix Angelicae Sinensis (RAS) and Radix Astragali (RA), has been widely used to treat menopausal irregularity in Chinese women for nearly 800 years. In this study, a comprehensive analytical method of simultaneously determining the main types of bioactive constituents, eighteen in all from the formula, involving flavonoids, saponins, organic acid and some volatile compounds, was developed. This method was based on HPLC coupled to a diode array and evaporative light scattering detectors (HPLC-DAD-ELSD) on a common reverse-phase C(18) column. Liquid chromatography coupled with on-line electrospray ionization mass spectrometry (LC-ESI-MS) was also used to further validate and analyze the constituents. It was found that 0.3% aqueous formic acid and acetonitrile was the optimum mobile phase for gradient elution. This method, which showed good precision and accuracy, was successfully used to quantify the bioactive constituents in six products. As a result, the validated HPLC method, together with the LC-ESI-MS analysis, provided a new basis for assessing the quality of traditional Chinese medicinal compound preparations (TCMCPs) consisting of many bioactive components.

  2. [Research on chemical fingerprint chromatograms of Sinopodophyllum hexandrum].

    PubMed

    Wang, Ai-Hua; Liu, Guang-Xue; Xu, Feng; Shang, Ming-Ying; Cai, Shao-Qing

    2013-10-01

    To study the HPLC fingerprint of Sinopodophylli Fructus, compare the major chemical differences in fruit of Sinopodophyllum hexandrum as well as the roots and rhizomas of S. hexandrum, and provide scientific evidence for clinical application and quality control. HPLC fingerprint method was used to analyze 12 fruits of S. hexandrum. A total of 20 common peaks were confirmed, and 12 peaks in the HPLC fingerprint were identified. Furthermore, similarity evaluation method and clustering analysis method were introduced to compare HPLC chromatograms, between fruits and underground parts. In this paper, quercetin-3-O-beta-D-glucopyranosid, kaempferol-3-O-beta-D-glucopyranoside, 8-prenylquercetin and 8-prenylquercetin 3-methyl ether were firstly reported in Sinopodophylli Fructus. Among the existing fingerprint research, a total of 11 peaks were identified for the first time, containing 9 flavonoids and 2 lignans. The chemical constituents differed significantly in different medicinal parts of S. hexandrum. Prenylflavonoid compounds were the main constituents of Sinopodophylli Fructus. However, podophyllotoxin, flavonoids with simple substituent groups and flavonoid glycosides were the major ingredients in the roots and rhizomas of S. hexandrum. This method can be used for the quality control of Sinopodophylli Fructus and the roots and rhizomas of S. hexandrum. It has provided a reference for the pharmacodynamic differences of the two different parts.

  3. [HPLC method to determine DEHP released into blood from a disposable extracorporeal circulation tube].

    PubMed

    Liu, Xi; Yu, Jingjing; Li, Shen; Wang, Hong; Liu, Jiaxin

    2013-08-01

    We used blood as leaching medium, simulating clinical operation under maximum condition, to develop Liquid-phase extraction- High Performance Liquid Chromatography (HPLC) method for determination of plasticizer Di-(2-ethylhexyl)phthalate (DEHP) released from Disposable Extracorporeal Circulation Tube in order to lay the foundation of risk analysis of this product. The characteristic wavelength of DEHP in methanol was detected. Acetonitrile was added to the leaching blood in proportion and extracted DEHP from blood. The methodology for HPLC to quantify DEHP was established and the DEHP amount released from this disposable extracorporeal circulation tube was measured. The experiments showed good results as follows. The characteristic wavelength of DEHP was 272nm. The concentration of DEHP (5-250 microg/mL) kept good linear relationship with peak area (r=0.9999). Method sensitivity was 1 microg/mL. Precisions showed RSD<5%. The adding standard extraction Recovery Rates of 25, 100 and 250 microg DEHP standard were 61.91 +/- 3.32)%, (69.38 +/- 0.55)% and (68.47 +/- 1.15)%. The DEHP maximum amounts released from 3 sets of this disposable extracorporeal circulation tube were 204.14, 106.30 and 165.34 mg/set. Our Liquid-phase Extraction-HPLC method showed high accuracy and precision, and relatively stable recovery rate. Its operation was also convenient.

  4. Evaluation of phosphorus characterization in broiler ileal digesta, manure, and litter samples: (31)P-NMR vs. HPLC.

    PubMed

    Leytem, A B; Kwanyuen, P; Plumstead, P W; Maguire, R O; Brake, J

    2008-01-01

    Using 31-phosphorus nuclear magnetic resonance spectroscopy ((31)P-NMR) to characterize phosphorus (P) in animal manures and litter has become a popular technique in the area of nutrient management. To date, there has been no published work evaluating P quantification in manure/litter samples with (31)P-NMR compared to other accepted methods such as high performance liquid chromatography (HPLC). To evaluate the use of (31)P-NMR to quantify myo-inositol hexakisphosphate (phytate) in ileal digesta, manure, and litter from broilers, we compared results obtained from both (31)P-NMR and a more traditional HPLC method. The quantification of phytate in all samples was very consistent between the two methods, with linear regressions having slopes ranging from 0.94 to 1.07 and r(2) values of 0.84 to 0.98. We compared the concentration of total monoester P determined with (31)P-NMR with the total inositol P content determined with HPLC and found a strong linear relationship between the two measurements having slopes ranging from 0.91 to 1.08 and r(2) values of 0.73 to 0.95. This suggests that (31)P-NMR is a very reliable method for quantifying P compounds in manure/litter samples.

  5. Monitoring of multiple bacteriocins through a developed dual extraction protocol and comparison of HPLC-DAD with turbidometry as their quantification system.

    PubMed

    Katharopoulos, Efstathios; Touloupi, Katerina; Touraki, Maria

    2016-08-01

    The present study describes the development of a simple and efficient screening system that allows identification and quantification of nine bacteriocins produced by Lactococcus lactis. Cell-free L. lactis extracts presented a broad spectrum of antibacterial activity, including Gram-negative bacteria, Gram-positive bacteria, and fungi. The characterization of their sensitivity to pH, and heat, showed that the extracts retained their antibacterial activity at extreme pH values and in a wide temperature range. The loss of antibacterial activity following treatment of the extracts with lipase or protease suggests a lipoproteinaceous nature of the produced antimicrobials. The extracts were subjected to a purification protocol that employs a two phase extraction using ammonium sulfate precipitation and organic solvent precipitation, followed by ion exchange chromatography, solid phase extraction and HPLC. In the nine fractions that presented antimicrobial activity, bacteriocins were quantified by the turbidometric method using a standard curve of nisin and by the HPLC method with nisin as the external standard, with both methods producing comparable results. Turbidometry appears to be unique in the qualitative determination of bacteriocins but the only method suitable to both separate and quantify the bacteriocins providing increased sensitivity, accuracy, and precision is HPLC. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Study of an Acid-Free Technique for the Preparation of Glycyrrhetinic Acid from Ammonium Glycyrrhizinate in Subcritical Water.

    PubMed

    Lekar, Anna V; Borisenko, Sergey N; Vetrova, Elena V; Filonova, Olga V; Maksimenko, Elena V; Borisenko, Nikolai I; Minkin, Vladimir I

    2015-11-01

    The aim of this work was to study an application of a previously developed expedient acid-free technique for the preparation of glycyrrhetinic acid from ammonium glycyrrhizinate that requires no use of acids and toxic organic solvents. Subcritical water that serves as a reactant and a solvent was used in order to obtain glycyrrhetinic acid in good yields starting from ammonium glycyrrhizinate. It has been shown that variation of only one parameter of the process (temperature) allows alteration to thecomposition of the hydrolysis products. A new method was used for the synthesis of glycyrrhetinic acid (glycyrrhizic acid aglycone) and its monoglycoside. HPLC combined with mass spectrometry and NMR spectroscopy were used to determine the quantitative and qualitative compositions of the obtained products. The method developed for the production of glycyrrhetinic acid in subcritical water is environmentally friendly and faster than conventional hydrolysis methods that use acids and-expensive and toxic organic solvents. The proposed technique has a potential for the future development of inexpensive and environmentally friendly technologies for production of new pharmaceutical plant-based substances.

  7. Quantitative determination of major active components in Ginkgo biloba dietary supplements by liquid chromatography/mass spectrometry.

    PubMed

    Ding, Shujing; Dudley, Ed; Plummer, Sue; Tang, Jiandong; Newton, Russell P; Brenton, A Gareth

    2006-01-01

    A reversed-phase high-performance liquid chromatography/electrospray ionisation mass spectrometry (RP-HPLC/ESI-MS) method was developed and validated for the simultaneous determination of ten major active components in Ginkgo biloba extract (bilobalide, ginkgolides A, B, C, quercetin, kaempferol, isorhamnetin, rutin hydrate, quercetin-3-beta-D-glucoside and quercitrin hydrate) which have not been previously reported to be quantified in a single analysis. The ten components exhibit baseline separation in 50 min by C18 chromatography using a water/1:1 (v/v) methanol/acetonitrile gradient. Quantitation was performed using negative ESI-MS in selected ion monitoring (SIM) mode. Good reproducibility and recovery were obtained by this method. The sensitivity of both UV and different mass spectrometry modes (full scan, selected ion monitoring (SIM), and selected reaction monitoring (SRM)) were compared and both quantitation with and without internal standard were evaluated. The analysis of Ginkgo biloba commercial products showed remarkable variations in the rutin and quercetin content as well as the terpene lactone contents although all the products satisfy the conventional quality control method. Copyright 2006 John Wiley & Sons, Ltd.

  8. Quality assessment of internet pharmaceutical products using traditional and non-traditional analytical techniques.

    PubMed

    Westenberger, Benjamin J; Ellison, Christopher D; Fussner, Andrew S; Jenney, Susan; Kolinski, Richard E; Lipe, Terra G; Lyon, Robbe C; Moore, Terry W; Revelle, Larry K; Smith, Anjanette P; Spencer, John A; Story, Kimberly D; Toler, Duckhee Y; Wokovich, Anna M; Buhse, Lucinda F

    2005-12-08

    This work investigated the use of non-traditional analytical methods to evaluate the quality of a variety of pharmaceutical products purchased via internet sites from foreign sources and compared the results with those obtained from conventional quality assurance methods. Traditional analytical techniques employing HPLC for potency, content uniformity, chromatographic purity and drug release profiles were used to evaluate the quality of five selected drug products (fluoxetine hydrochloride, levothyroxine sodium, metformin hydrochloride, phenytoin sodium, and warfarin sodium). Non-traditional techniques, such as near infrared spectroscopy (NIR), NIR imaging and thermogravimetric analysis (TGA), were employed to verify the results and investigate their potential as alternative testing methods. Two of 20 samples failed USP monographs for quality attributes. The additional analytical methods found 11 of 20 samples had different formulations when compared to the U.S. product. Seven of the 20 samples arrived in questionable containers, and 19 of 20 had incomplete labeling. Only 1 of the 20 samples had final packaging similar to the U.S. products. The non-traditional techniques complemented the traditional techniques used and highlighted additional quality issues for the products tested. For example, these methods detected suspect manufacturing issues (such as blending), which were not evident from traditional testing alone.

  9. Simultaneous Estimation of Withaferin A and Z-Guggulsterone in Marketed Formulation by RP-HPLC.

    PubMed

    Agrawal, Poonam; Vegda, Rashmi; Laddha, Kirti

    2015-07-01

    A simple, rapid, precise and accurate high-performance liquid chromatography (HPLC) method was developed for simultaneous estimation of withaferin A and Z-guggulsterone in a polyherbal formulation containing Withania somnifera and Commiphora wightii. The chromatographic separation was achieved on a Purosphere RP-18 column (particle size 5 µm) with a mobile phase consisting of Solvent A (acetonitrile) and Solvent B (water) with the following gradients: 0-7 min, 50% A in B; 7-9 min, 50-80% A in B; 9-20 min, 80% A in B at a flow rate of 1 mL/min and detection at 235 nm. The marker compounds were well separated on the chromatogram within 20 min. The results obtained indicate accuracy and reliability of the developed simultaneous HPLC method for the quantification of withaferin A and Z-guggulsterone. The proposed method was found to be reproducible, specific, precise and accurate for simultaneous estimation of these marker compounds in a combined dosage form. The HPLC method was appropriate and the two markers are well resolved, enabling efficient quantitative analysis of withaferin A and Z-guggulsterone. The method can be successively used for quantitative analysis of these two marker constituents in combination of marketed polyherbal formulation. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Simultaneous determination of seven lignans in Justicia procumbens by high performance liquid chromatography-photodiode array detection using relative response factors.

    PubMed

    Luo, Zuliang; Kong, Weijun; Qiu, Feng; Yang, Meihua; Li, Qian; Wei, Riwei; Yang, Xiaoli; Qin, Jieping

    2013-02-01

    A simple and sensitive HPLC coupled with photodiode array (HPLC-PDA) method was developed for simultaneous determination of seven lignans in Justicia procumbens using relative response factors (RRFs). The chromatographic separation was performed on a Shiseido Capcell Pak C(18) column (250 × 4.6 mm id, 5 μm), a gradient elution of acetonitrile/water, and a photodiode array detector. The column temperature was maintained at 35°C and the detection wavelength was set at 256 nm. Chinensinaphthol methyl ether was selected as the reference compound for calculating the relative response factors of the lignans. It has shown that the RRFs for lignans are quite similar at 256 nm of detection under different analytical conditions (different columns and HPLC instruments). Using RRFs, not every lignan is needed as a reference standard, making the method ideal for rapid, routine analysis, especially for those laboratories where lignans standards are not readily available. An economic and practicable HPLC method using RRFs was established for the determination of seven lignans in J. procumbens. This method not only can determine multiple indexes in traditional Chinese medicines (TCMs) simultaneously, but also resolve the problem of lacking of chemical standards. It will be a good quality evaluation method and pattern for TCMs. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Simultaneous Speciation of Arsenic, Selenium, and Chromium by HPLC-ICP-MS

    USGS Publications Warehouse

    Wolf, Ruth E.; Morman, Suzette A.; Morrison, Jean M.; Lamothe, Paul J.

    2008-01-01

    An adaptation of an analytical method developed for chromium speciation has been utilized for the simultaneous determination of As(III), As(V), Se(IV), Se(VI), Cr(III), and Cr(VI) species using high performance liquid chromatography (HPLC) separation with ICP-MS detection. Reduction of interferences for the determination of As, Se, and Cr by ICP-MS is a major consideration for this method. Toward this end, a Dynamic Reaction Cell (DRC) ICP-MS system was used to detect the species eluted from the chromatographic column. A variety of reaction cell gases and conditions may be utilized, and the advantages and limitations of the gases tested to date will be presented and discussed. The separation and detection of the As, Se, and Cr species of interest can be achieved using the same chromatographic conditions in less than 2 minutes by complexing the Cr(III) with EDTA prior to injection on the HPLC column. Practical aspects of simultaneous speciation analysis will be presented and discussed, including issues with HPLC sample vial contamination, standard and sample contamination, species stability, and considerations regarding sample collection and preservation methods. The results of testing to determine the method's robustness to common concomitant element and anion effects will also be discussed. Finally, results will be presented using the method for the analysis of a variety of environmental and geological samples including waters, soil leachates and simulated bio-fluid leachates.

  12. Optimizing pressurized liquid extraction of microbial lipids using the response surface method.

    PubMed

    Cescut, J; Severac, E; Molina-Jouve, C; Uribelarrea, J-L

    2011-01-21

    Response surface methodology (RSM) was used for the determination of optimum extraction parameters to reach maximum lipid extraction yield with yeast. Total lipids were extracted from oleaginous yeast (Rhodotorula glutinis) using pressurized liquid extraction (PLE). The effects of extraction parameters on lipid extraction yield were studied by employing a second-order central composite design. The optimal condition was obtained as three cycles of 15 min at 100°C with a ratio of 144 g of hydromatrix per 100 g of dry cell weight. Different analysis methods were used to compare the optimized PLE method with two conventional methods (Soxhlet and modification of Bligh and Dyer methods) under efficiency, selectivity and reproducibility criteria thanks to gravimetric analysis, GC with flame ionization detector, High Performance Liquid Chromatography linked to Evaporative Light Scattering Detector (HPLC-ELSD) and thin-layer chromatographic analysis. For each sample, the lipid extraction yield with optimized PLE was higher than those obtained with referenced methods (Soxhlet and Bligh and Dyer methods with, respectively, a recovery of 78% and 85% compared to PLE method). Moreover, the use of PLE led to major advantages such as an analysis time reduction by a factor of 10 and solvent quantity reduction by 70%, compared with traditional extraction methods. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Rapid Development and Validation of Improved Reversed-Phase High-performance Liquid Chromatography Method for the Quantification of Mangiferin, a Polyphenol Xanthone Glycoside in Mangifera indica

    PubMed Central

    Naveen, P.; Lingaraju, H. B.; Prasad, K. Shyam

    2017-01-01

    Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica, is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica. RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed < 1% of relative standard deviation of peak area indicated high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value < 1% shows high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography–mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica. SUMMARY The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica. The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed assay by HPLC method is a simple, rapid and reliable for the quantification of the mangiferin from M. indica. Abbreviations Used: M. indica: Mangifera indica, RP-HPLC: Reversed-phase high-performance liquid chromatography, M/Z: Mass to charge ratio, ICH: International conference on harmonization, % RSD: Percentage of relative standard deviation, ppm: Parts per million, LOD: Limit of detection, LOQ: Limit of quantification. PMID:28539748

  14. Rapid Development and Validation of Improved Reversed-Phase High-performance Liquid Chromatography Method for the Quantification of Mangiferin, a Polyphenol Xanthone Glycoside in Mangifera indica.

    PubMed

    Naveen, P; Lingaraju, H B; Prasad, K Shyam

    2017-01-01

    Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica , is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica . RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed < 1% of relative standard deviation of peak area indicated high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value < 1% shows high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography-mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica . The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica . The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed assay by HPLC method is a simple, rapid and reliable for the quantification of the mangiferin from M. indica . Abbreviations Used: M. indica : Mangifera indica , RP-HPLC: Reversed-phase high-performance liquid chromatography, M/Z: Mass to charge ratio, ICH: International conference on harmonization, % RSD: Percentage of relative standard deviation, ppm: Parts per million, LOD: Limit of detection, LOQ: Limit of quantification.

  15. Evaluation of multiple reaction monitoring cubed for the analysis of tachykinin related peptides in rat spinal cord using a hybrid triple quadrupole-linear ion trap mass spectrometer.

    PubMed

    Pailleux, Floriane; Beaudry, Francis

    2014-02-01

    Targeted peptide methods generally use HPLC-MS/MRM approaches. Although dependent on the instrumental resolution, interferences may occur while performing analysis of complex biological matrices. HPLC-MS/MRM(3) is a technique, which provides a significantly better selectivity, compared with HPLC-MS/MRM assay. HPLC-MS/MRM(3) allows the detection and quantitation by enriching standard MRM with secondary product ions that are generated within the linear ion trap. Substance P (SP) and neurokinin A (NKA) are tachykinin peptides playing a central role in pain transmission. The objective of this study was to verify whether HPLC-MS/MRM(3) could provide significant advantages over a more traditional HPLC-MS/MRM assay for the quantification of SP and NKA in rat spinal cord. The results suggest that reconstructed MRM(3) chromatograms display significant improvements with the nearly complete elimination of interfering peaks but the sensitivity (i.e. signal-to-noise ratio) was severely reduced. The precision (%CV) observed was between 3.5% and 24.1% using HPLC-MS/MRM and in the range of 4.3-13.1% with HPLC-MS/MRM(3), for SP and NKA. The observed accuracy was within 10% of the theoretical concentrations tested. HPLC-MS/MRM(3) may improve the assay sensitivity to detect difference between samples by reducing significantly the potential of interferences and therefore reduce instrumental errors. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. HPLC and TLC methods for analysis of [18F]FDG and its metabolites from biological samples.

    PubMed

    Rokka, Johanna; Grönroos, Tove J; Viljanen, Tapio; Solin, Olof; Haaparanta-Solin, Merja

    2017-03-24

    The most used positron emission tomography (PET) tracer, 2-[ 18 F]fluoro-2-deoxy-d-glucose ([ 18 F]FDG), is a glucose analogue that is used to measure tissue glucose consumption. Traditionally, the Sokoloff model is the basis for [ 18 F]FDG modeling. According to this model, [ 18 F]FDG is expected to be trapped in a cell in the form of [ 18 F]FDG-6-phosphate ([ 18 F]FDG-6-P). However, several studies have shown that in tissues, [ 18 F]FDG metabolism goes beyond [ 18 F]FDG-6-P. Our aim was to develop radioHPLC and radioTLC methods for analysis of [ 18 F]FDG metabolites from tissue samples. The radioHPLC method uses a sensitive on-line scintillation detector to detect radioactivity, and the radioTLC method employs digital autoradiography to detect the radioactivity distribution on a TLC plate. The HPLC and TLC methods were developed using enzymatically in vitro-produced metabolites of [ 18 F]FDG as reference standards. For this purpose, three [ 18 F]FDG metabolites were synthesized: [ 18 F]FDG-6-P, [ 18 F]FD-PGL, and [ 18 F]FDG-1,6-P2. The two methods were evaluated by analyzing the [ 18 F]FDG metabolic profile from rodent ex vivo tissue homogenates. The HPLC method with an on-line scintillation detector had a wide linearity in a range of 5Bq-5kBq (LOD 46Bq, LOQ 139Bq) and a good resolution (Rs ≥1.9), and separated [ 18 F]FDG and its metabolites clearly. The TLC method combined with digital autoradiography had a high sensitivity in a wide range of radioactivity (0.1Bq-2kBq, LOD 0.24Bq, LOQ 0.31Bq), and multiple samples could be analyzed simultaneously. As our test and the method validation with ex vivo samples showed, both methods are useful, and at best they complement each other in analysis of [ 18 F]FDG and its radioactive metabolites from biological samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. [Study on HPLC fingerprint of flavonoids from Houttuynia cordata by comparing with fingerprint reference].

    PubMed

    Zhang, Ting-Ting; Wu, Yi; Hang, Tai-Jun

    2009-05-01

    To establish a stable and repeatable HPLC fingerprint standard and evaluate the flavonoids from Houttuynia cordata qualitatively and quantitatively. HPLC separation was performed on a C18 column with methanol-0.1% phosphoric acid mixed solution as mobile phase in gradient elution mode. The fingerprint reference was determined as one of the most typical chromatograms and used to be compared with other samples through Cosine and Relative Euclid Distance methods, thus the chromatographic fingerprints of flavonoids from Houttuynia cordata were evaluated by constitutes and contents, respectively. Fourteen mutual peaks were fixed in the HPLC fingerprint of flavonoids from Houttaynia cordata. It showed good results in validation tests in which the quercitrin's peak was set as the reference peak to calculate relative retention time and area of other peaks in the chromatograms, and the RSD were less than 0.2% and 5.0%, respectively. The linear ranges for quercitrin was 1.07-83.4 microg/mL (r=0.9999) and the average recovery was 100.3%. The method shows good repeatability, ruggedness and reliability. Comparing with the established reference fingerprint, the evaluation system including Cosine and Relative Euclid Distance methods lays dependable foundation for controlling the quality of Houttuynia cordata.

  18. Determination of pKa values of some antipsychotic drugs by HPLC--correlations with the Kamlet and taft solvatochromic parameters and HPLC analysis in dosage forms.

    PubMed

    Sanli, Senem; Akmese, Bediha; Altun, Yuksel

    2013-01-01

    In this study, ionization constant (pKa) values were determined by using the dependence of the retention factor on the pH of the mobile phase for four ionizable drugs, namely, risperidone (RI), clozapine (CL), olanzapine (OL), and sertindole (SE). The effect of the mobile phase composition on the pKa was studied by measuring the pKa at different acetonitrile-water mixtures in an HPLC-UV method. To explain the variation of the pKa values obtained over the whole composition range studied, the quasi-lattice quasi-chemical theory of preferential solvation was applied. The pKa values of drugs were correlated with the Kamlet and Taft solvatochromic parameters. Kamlet and Taft's general equation was reduced to two terms by using combined factor analysis and target factor analysis in these mixtures: the independent term and the hydrogen-bond donating ability a. The HPLC-UV method was successfully applied for the determination of RI, OL, and SE in pharmaceutical dosage forms. CL was chosen as an internal standard. Additionally, the repeatability, reproducibility, selectivity, precision, and accuracy of the method in all media were investigated and calculated.

  19. [HPLC-ESI-MS(n) analysis of the water soluble extracts of Fructus Choerospondiatis].

    PubMed

    Shi, Run-ju; Dai, Yun; Fang, Min-feng; Zhao, Xin; Zheng, Jian-bin; Zheng, Xiao-hui

    2007-03-01

    To establish an HPLC-ESI-MS(n) method for analyzing the chemical ingredients in the water soluble extracts of Fructus Choerospondiatis. Water-solvable extracts of Fructus Choerospondiatis are obtained by heating recirculation. Multi-stage reaction mode (MRM) of the HPLC-ESI-MS(n) was used to determine the content of Gallic acid, the MS(n) technology was used to obtain the information of characteristic multistage fragment ions so as to identify the chemical structure of peaks in the total current spectrum. Eleven compounds were identified, and one of them is a new unknown ingredient. The method, which has high recovery and specificity, can offer the experimental evidences for the further research of the chemical ingredients extracted from the Fructus Choerospondiatis.

  20. Measurement of Menadione in urine by HPLC

    USDA-ARS?s Scientific Manuscript database

    Menadione may be an important metabolite of vitamin K that is excreted in urine. A high performance liquid chromatography (HPLC) method with a C30 column, fluorescence detection and post-column zinc reduction was developed to measure menadione in urine. The mobile phase was composed of 95% methanol...

  1. HPLC-ELSD Quantification and Centrifugal Partition Chromatography Isolation of 8-O-Acetylharpagide from Oxera coronata (Lamiaceae).

    PubMed

    Remeur, Camille; Le Borgne, Erell; Gauthier, Léa; Grougnet, Raphaël; Deguin, Brigitte; Poullain, Cyril; Litaudon, Marc

    2017-05-01

    Iridoid glycosides possess highly functionalised monoterpenoid aglycon with several contiguous stereocentres. For the most common, they are often present in quantities reaching several percentage of the fresh plant weight, and thus they may be regarded as starting material for the synthesis of a number of new chiral and bioactive molecules. To quantify and to isolate 8-O-acetylharpagide (AH) from several extracts of Oxera coronata R.P.J. de Kok, a Lamiaceae species endemic to New Caledonia, using HPLC-ELSD (evaporative light scattering detector) and centrifugal partition chromatography (CPC). Oxera coronata produces high amounts of AH in leaves, twigs and fruits. Water and methanol extracts of these plant parts were prepared. The content of AH in each extract was quantified by HPLC-ELSD, using acetonitrile-water (+0.1% formic acid) gradient elution. The HPLC method was validated for precision, linearity, limit of detection (LOD), limit of quantification (LOQ) and accuracy. A ternary solvent system ethyl acetate/n-propanol/water (3:2:5, v/v/v) was selected and applied to recover the target compound using Spot CPC from the leaves aqueous extract. HPLC-ELSD analysis followed by CPC purification led to the efficient isolation of AH from O. coronata leaves aqueous extract. HPLC-ELSD has proven to be a well-adapted detection and quantification method for iridoid glycosides, while CPC confirmed to be an efficient technique for the isolation of polar compounds. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Profiling indomethacin impurities using high-performance liquid chromatography and nuclear magnetic resonance.

    PubMed

    Hess, S; Teubert, U; Ortwein, J; Eger, K

    2001-12-01

    The anti-inflammatory drug indomethacin was investigated regarding new related impurities. Therefore, related substances 2-9 were prepared by independent synthesis and physicochemically characterized. To determine indomethacin and its related substances, a new HPLC-UV method was developed and validated. Indomethacin and its impurities were eluted on a C(18) column with a mobile phase consisting of methanol and an aqueous solution of 0.2% phosphoric acid at a flow rate of 1.5 ml/min and were quantified by UV detection at 320 nm. Overall, the HPLC-UV method was simple and reliable for the detection of eight impurities in indomethacin. In addition to the HPLC-UV method, 1H nuclear magnetic resonance (NMR) was used to investigate indomethacin regarding impurities. For that purpose, related substances 2-9 were systematically added to indomethacin and investigated. The NMR method was found to be very useful for the identification of impurities in bulk substance without prior separation. Both HPLC-UV and NMR were used to analyze 38 batches of indomethacin available on the European market. The outcome was that 42% of the batches did not meet the compendial requirements although they met the specifications of current compendial methods. Some batches contained the previously undescribed impurity 8, while other batches contained by-products from two distinct synthetic routes. The methods presented herein are important contributions to the ongoing efforts to reduce impurities and therefore the risk of adverse side-effects in drugs that are no longer under patent protection.

  3. Comparison of high-performance liquid chromatography/tandem mass spectrometry and high-performance liquid chromatography/photo-diode array detection for the quantitation of carotenoids, retinyl esters, α-tocopherol and phylloquinone in chylomicron-rich fractions of human plasma.

    PubMed

    Kopec, Rachel E; Schweiggert, Ralf M; Riedl, Ken M; Carle, Reinhold; Schwartz, Steven J

    2013-06-30

    Bioavailability of essential lipophilic micronutrients and carotenoids is of utmost interest for human health, as the consumption of these compounds may help alleviate major nutritional deficiencies, cardiovascular disease, and cancer. High-performance liquid chromatography/photo-diode array detection (HPLC-PDA) and high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) were compared for the quantitative analysis of α- and β-carotene, β-cryptoxanthin, lutein, lycopene, α-tocopherol, phylloquinone, and several retinyl esters from chylomicron-containing triglyceride rich lipoprotein (TRL) fractions of human plasma obtained from two clinical trials. After selecting an efficient extraction method for the analytes, both the HPLC/PDA and the HPLC/MS/MS methods were developed and several parameters validated using an HP 1200 series HPLC system interfaced with a HP 1200 series diode-array detector (Agilent Technologies, Santa Clara, CA, USA) and a QTRAP 5500 (AB Sciex, Foster City, CA, USA) via an atmospheric pressure chemical ionization (APCI) probe operated in positive ion mode. For lycopene, α- and β-carotene, HPLC/MS/MS was up to 37 times more sensitive than HPLC-PDA. PDA detection was shown to be up to 8 times more sensitive for lutein. MS/MS signals were enhanced by matrix components for lutein and β-cryptoxanthin, as determined by referencing to the matrix-independent PDA signal. In contrast, matrix suppression was observed for retinyl palmitate, α-carotene, and β-carotene. Both detectors showed similar suitability for α-tocopherol, lycopene and retinyl palmitate (representing ~73% of total retinyl esters). MS/MS exclusively allowed the quantitation of minor retinyl esters, phylloquinone, and (Z)-lycopene isomers. HPLC/MS/MS was more sensitive than HPLC-PDA for six of the eight analytes and represents a powerful tool for the analysis of chylomicron samples and potentially other biological samples of limited sample size. When internal standards are available for the target carotenoid, employing MS/MS detection may reduce the necessary blood sample volume, which is particularly advantageous for minimizing risk and discomfort to human subjects during clinical studies. Copyright © 2013 John Wiley & Sons, Ltd.

  4. Simultaneous Determination of Ursodeoxycholic Acid and Chenodeoxycholic Acid in Pharmaceutical Dosage Form by HPLC-UV Detection.

    PubMed

    Khairy, Mostafa A; Mansour, Fotouh R

    2017-01-01

    A reversed-phase HPLC method was developed for the simultaneous determination of ursodeoxycholic acid (UDCA) and the epimeric isomer, chenodeoxycholic acid (CDCA), in their synthetic mixtures and in tablet dosage form. The proposed HPLC method uses a C18 column and mobile phase consisting of an acetonitrile-phosphate buffer mixture (pH 2.3, 100 mM; 50 + 50, v/v) at a flow rate of 2.0 mL/min with UV detection at 210 nm. The method was validated according to the International Conference on Harmonization guidelines; and linearity, range, accuracy, precision, robustness, and system suitability were studied. The LOD and LOQ were also calculated and found to be 1.23 and 3.73 μg/mL for UDCA and 0.83 and 2.52 μg/mL for CDCA, respectively. The method was adapted for UHPLC, in which baseline separation was achieved in <2.5 min. The assay results of Ursomix tablets by the developed method were statistically compared with those obtained by the reference method using t- and F-tests, and no significant differences were observed.

  5. Rifaximin Stability: A Look at UV, IR, HPLC, and Turbidimetry Methods.

    PubMed

    Kogawa, Ana Carolina; Salgado, Hérida Regina Nunes

    2018-03-01

    The study of the stability of medicines is mandated by the International Conference on Harmonization and the World Health Organization. Rifaximin, an antimicrobial marketed in the form of tablets, has no record of stability studies. Thus, the objective of the present work was to investigate the behavior and stability of rifaximin tablets for 6 months under simultaneous conditions of temperature and humidity by UV, IR, HPLC, and turbidimetry techniques. After 6 months of stability study, rifaximin tablets were shown to obey zero-order kinetics when analyzed by physicochemical methods and second-order kinetics when analyzed by a microbiological method. However, the UV method was not suitable for the evaluation of rifaximin. IR, HPLC, and turbidimetry methods can already be used to evaluate the stability of rifaximin tablets. It is important to analyze products with more than one type of method before releasing results mainly in the case of antimicrobial products in which the association of physicochemical and microbiological techniques must be a rule. Rifaximin tablets can be considered stable after 6 months under conditions of 40 ± 2°C and 75 ± 5% relative humidity.

  6. Rapid, Potentially Automatable, Method Extract Biomarkers for HPLC/ESI/MS/MS to Detect and Identify BW Agents

    DTIC Science & Technology

    1997-11-01

    status can sometimes be reflected in the infectious potential or drug resistance of those pathogens. For example, in Mycobacterium tuberculosis ... Mycobacterium tuberculosis , its antibiotic resistance and prediction of pathogenicity amongst Mycobacterium spp. based on signature lipid biomarkers ...TITLE AND SUBTITLE Rapid, Potentially Automatable, Method Extract Biomarkers for HPLC/ESI/MS/MS to Detect and Identify BW Agents 5a. CONTRACT NUMBER 5b

  7. Development and validation of a reversed-phase fluorescence HPLC method for determination of bucillamine in human plasma using pre-column derivatization with monobromobimane.

    PubMed

    Lee, Kang Choon; Chun, Young Goo; Kim, Insoo; Shin, Beom Soo; Park, Eun-Seok; Yoo, Sun Dong; Youn, Yu Seok

    2009-07-15

    A simple, specific and sensitive derivatization with monobromobimane (mBrB) and the corresponding HPLC-fluorescence quantitation method for the analysis of bucillamine in human plasma was developed and validated. The analytical procedure involves a simple protein precipitation, pre-column fluorescence derivatization, and separation by reversed-phase high performance liquid chromatography (RP-HPLC). The calibration curve showed good linearity over a wide concentration range (50 ng/mL to 10 microg/mL) in human plasma (r(2)=0.9998). The lower limit of quantitation (LLOQ) was 50 ng/mL. The average precision and accuracy at LLOQ were within 6.3% and 107.6%, respectively. This method was successfully applied to a pharmacokinetic study after oral administration of a dose (300 mg) of bucillamine to 20 healthy Korean volunteers.

  8. Measurement of Menadione in Urine by HPLC

    PubMed Central

    Rajabi, Ala Al; Peterson, James; Choi, Sang Woon; Suttie, John; Barakat, Susan; Booth, Sarah L

    2010-01-01

    Menadione is a metabolite of vitamin K that is excreted in urine. A high performance liquid chromatography (HPLC) method using a C30 column, post-column zinc reduction and fluorescence detection was developed to measure urinary menadione. The mobile phase was composed of 95% methanol with 0.55% aqueous solution and 5% DI H2O. Menaquinone-2 (MK-2) was used as an internal standard. The standard calibration curve was linear with a correlation coefficient (R2) of 0.999 for both menadione and MK-2. The lower limit of quantification (LLOQ) was 0.3 pmole menadione/mL urine. Sample preparation involved hydrolysis of menadiol conjugates and oxidizing the released menadiol to menadione. Using this method, urinary menadione was shown to increase in response to 3 years of phylloquinone supplementation. This HPLC method is a sensitive and reproducible way to detect menadione in urine. Research support: USDA ARS Cooperative Agreement 58-1950-7-707. PMID:20719580

  9. Measurement of menadione in urine by HPLC.

    PubMed

    Al Rajabi, Ala; Peterson, James; Choi, Sang-Woon; Suttie, John; Barakat, Susan; Booth, Sarah L

    2010-09-15

    Menadione is a metabolite of vitamin K that is excreted in urine. A high performance liquid chromatography (HPLC) method using a C(30) column, post-column zinc reduction and fluorescence detection was developed to measure urinary menadione. The mobile phase was composed of 95% methanol with 0.55% aqueous solution and 5% DI H(2)O. Menaquinone-2 (MK-2) was used as an internal standard. The standard calibration curve was linear with a correlation coefficient (R(2)) of 0.999 for both menadione and MK-2. The lower limit of quantification (LLOQ) was 0.3pmole menadione/mL urine. Sample preparation involved hydrolysis of menadiol conjugates and oxidizing the released menadiol to menadione. Using this method, urinary menadione was shown to increase in response to 3 years of phylloquinone supplementation. This HPLC method is a sensitive and reproducible way to detect menadione in urine. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  10. Selective identification and quantification of saccharin by liquid chromatography and fluorescence detection.

    PubMed

    Bruno, Sergio N F; Cardoso, Carlos R; Maciel, Márcia Mosca A; Vokac, Lidmila; da Silva Junior, Ademário I

    2014-09-15

    High-pressure liquid chromatography with ultra-violet detection (HPLC-UV) is one of the most commonly used methods to identify and quantify saccharin in non-alcoholic beverages. However, due to the wide variety of interfering UV spectra in saccharin-containing beverage matrices, the same method cannot be used to measure this analyte accurately. We have developed a new, highly effective method to identify and quantify saccharin using HPLC with fluorescence detection (HPLC-FLD). The excitation wavelength (250 nm) and emission wavelength (440 nm) chosen increased selectivity for all matrices and ensured few changes were required in the mobile phase or other parameters. The presence of saccharin in non-diet beverages - a fraud commonly used to replace more expensive sucrose - was confirmed by comparing coincident peaks as well as the emission spectra of standards and samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Analysis Study of Stevioside and Rebaudioside A from Stevia rebaudiana Bertoni by Normal Phase SPE and RP-HPLC

    NASA Astrophysics Data System (ADS)

    Martono, Y.; Rohman, A.; Riyanto, S.; Martono, S.

    2018-04-01

    Solid Phase Extraction (SPE) method using silica as sorbent for stevioside and rebaudiosida A analysis in Stevia rebaudiana Bertoni leaf have not been performed. The aim of this study is to develop SPE method using silica as sorbent for Reverse Phase-High Performance Liquid Chromatography (RP-HPLC) analysis of stevioside and rebaudiosida A in S. rebaudiana leaf. The results of this study indicate that the optimal conditions for normal phase SPE (silica) are conditioned with 3.0 mL of hexane. The sample loading volume is 0.1 mL. Cartridge is eluted with 1.0 mL acetonitrile: water (80: 20, v/v) to separate both analytes. The cartridge is washed with chloroform and water of 0.3 mL respectively. The developed SPE sample preparation method meets the accuracy and precision test and can be used for the analysis of stevioside and rebaudioside A by RP-HPLC.

  12. Comparison of capillary electrophoresis and high performance liquid chromatography for detection and quantification of hemoglobin New York.

    PubMed

    You-Qiong, Li; Hui-Ping, Huang; Zhi-Zhong, Chen; Lin, Zhao; Liang, Liang; Gui-Fang, Qin; Yun, Mo

    2016-01-01

    Hemoglobin (Hb) New York [β113 (G15) Val→Glu, GTG→GAG], also known as Hb Kaohsiung, is one of the most common Hb variants in South China. Currently, most used screening methods for hemoglobinopathies in South China are high performance liquid chromatography (HPLC) and capillary electrophoresis (CE). However, there is no study comparing the performance of CE and HPLC in the detection of Hb New York. In total 15 samples (including 13 adult blood samples and 2 cord blood samples) with heterozygous Hb New York were analyzed by CE and HPLC. Levels of Hb New York, HbA2, Hb, mean corpuscular volume (MCV) and mean corpuscular hemoglobin (MCH) were compared within the two groups. All 15 cases (100%) were detected by CE, whereas none was detected by HPLC. Mean values of Hb New York and HbA2 in adult heterozygous group were (43.82±2.47)% and (2.85±0.31)%, respectively; mean values for cord blood group were (7.95±0.78)% and (0.30±0.14)%. CE allows the detection of Hb New York, while this variant is not separated from Hb A on HPLC. CE may be the preferred method for hemoglobinopathy screening in areas with high prevalence of Hb New York.

  13. Metabolite profiling with HPLC-ICP-MS as a tool for in vivo characterization of imaging probes.

    PubMed

    Boros, Eszter; Pinkhasov, Omar R; Caravan, Peter

    2018-01-01

    Current analytical methods for characterizing pharmacokinetic and metabolic properties of positron emission tomography (PET) and single photon emission computed tomography (SPECT) probes are limited. Alternative methods to study tracer metabolism are needed. The study objective was to assess the potential of high performance liquid chromatography - inductively coupled plasma - mass spectrometry (HPLC-ICP-MS) for quantification of molecular probe metabolism and pharmacokinetics using stable isotopes. Two known peptide-DOTA conjugates were chelated with nat Ga and nat In. Limit of detection of HPLC-ICP-MS for 69 Ga and 115 In was determined. Rats were administered 50-150 nmol of Ga- and/or In-labeled probes, blood was serially sampled, and plasma analyzed by HPLC-ICP-MS using both reverse phase and size exclusion chromatography. The limits of detection were 0.16 pmol for 115 In and 0.53 pmol for 69 Ga. Metabolites as low as 0.001 %ID/g could be detected and transchelation products identified. Simultaneous administration of Ga- and In-labeled probes allowed the determination of pharmacokinetics and metabolism of both probes in a single animal. HPLC-ICP-MS is a robust, sensitive and radiation-free technique to characterize the pharmacokinetics and metabolism of imaging probes.

  14. Methods and applications of HPLC-AMS (WBio 5)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bucholz, B A; Clifford, A J; Duecker, S R

    Pharmacokinetics of physiologic doses of nutrients, pesticides, and herbicides can easily be traced in humans using a {sup 14}C-labelled compound. Basic kinetics can be monitored in blood or urine by measuring the elevation in the {sup 14}C content above the control predose tissue and converting to equivalents of the parent compound. High Performance Liquid Chromatography (HPLC) is an excellent method for the chemical separation of complex mixtures whose profiles afford estimation of biochemical pathways of metabolism. Compounds elute from the HPLC systems with characteristic retention times and can be collected in fractions that can then be graphitized for AMS measurement.more » Unknowns are identified by coelution with known standards and chemical tests that reveal functional groupings. Metabolites are quantified with the {sup 14}C signal. Thoroughly accounting for the carbon inventory in the LC solvents, ion-pairing agents, samples, and carriers adds some complexity to the analysis. In most cases the total carbon inventory is dominated by carrier. Baseline background and stability need to be carefully monitored. Limits of quantitation near 10 amol of {sup 14}C per HPLC fraction are typically achieved. Baselines are maintained by limiting injected {sup 14}C activity <0.17 Bq (4.5 pCi) on the HPLC column.« less

  15. Analysis of the constituents of aqueous preparations of Stachys recta by HPLC-DAD and HPLC-ESI-MS.

    PubMed

    Karioti, Anastasia; Bolognesi, Letizia; Vincieri, Franco Francesco; Bilia, Anna Rita

    2010-09-21

    In the present study a method based on liquid chromatography with diode array detection (HPLC/DAD) coupled to an electrospray ionization (ESI) interface for the simultaneous determination of phenolic constituents in three aqueous preparations of the herbal medicinal drug Stachys recta. The developed assay was simple and effective and permitted the quality control of S. recta decoctions and infusion. Overall, 30 constituents were detected and identified, belonging mainly to three classes of compounds: caffeoylquinic acids, phenylethanol glycosides and flavonoids. 15 of them were quantified having a lower limit not less than 0.02% of the lyophilized extracts. Only seven of them were previously reported in this species, while 23 were identified for the first time as constituents of S. recta. HPLC-DAD-ESI-MS analysis provided evidence for the certain identification of the main constituents and in some cases of their isomers. Eight constituents were isolated and their structure elucidated by HPLC-ESI-MS and 1D- and 2D-NMR spectroscopy. Among the investigated preparations, the infusion seems to be the best method to extract the native constituents of the plant, while decoction is a more aggressive treatment and causes partial degradation of some acylated flavonoids. Copyright 2010 Elsevier B.V. All rights reserved.

  16. Two-dimensional fingerprinting approach for comparison of complex substances analysed by HPLC-UV and fluorescence detection.

    PubMed

    Ni, Yongnian; Liu, Ying; Kokot, Serge

    2011-02-07

    This work is concerned with the research and development of methodology for analysis of complex mixtures such as pharmaceutical or food samples, which contain many analytes. Variously treated samples (swill washed, fried and scorched) of the Rhizoma atractylodis macrocephalae (RAM) traditional Chinese medicine (TCM) as well as the common substitute, Rhizoma atractylodis (RA) TCM were chosen as examples for analysis. A combined data matrix of chromatographic 2-D HPLC-DAD-FLD (two-dimensional high performance liquid chromatography with diode array and fluorescence detectors) fingerprint profiles was constructed with the use of the HPLC-DAD and HPLC-FLD individual data matrices; the purpose was to collect maximum information and to interpret this complex data with the use of various chemometrics methods e.g. the rank-ordering multi-criteria decision making (MCDM) PROMETHEE and GAIA, K-nearest neighbours (KNN), partial least squares (PLS), back propagation-artificial neural networks (BP-ANN) methods. The chemometrics analysis demonstrated that the combined 2-D HPLC-DAD-FLD data matrix does indeed provide more information and facilitates better performing classification/prediction models for the analysis of such complex samples as the RAM and RA ones noted above. It is suggested that this fingerprint approach is suitable for analysis of other complex, multi-analyte substances.

  17. Determination of Trace Level Triclosan in Water by Online Preconcentration and HPLC-UV Diode Array

    EPA Science Inventory

    An online high performance liquid chromatography (HPLC) method for the detection and quantification of trace levels of triclosan in water is discussed. Triclosan, an anti-bacterial agent, and related compounds have been shown to reach municipal waste waters through the disposal ...

  18. [Study on HPLC fingerprint of Alpinia officinarum].

    PubMed

    Deng, Yi-Feng; Feng, Li-Na; Luo, Hui

    2011-09-01

    To establish the chromatography fingerprint of Alpinia officinarum by HPLC. An optimum HPLC conditions which were obtained under the assessment of LC-MS were as follows: Shim-pack VP-ODS column (2.0 mm x 250 mm, 5 microm), 0.1% HAc aqueous solution as phase A, 15% Acetonitrile: 40% Methanol: 45% Tetrafuran as phase B, the flow rate was 0.20 mL/min, column temperature was 35 degrees C and UV detector was set at 280 nm. The HPLC fingerprint of Alpinia officinarum was established, the consensus 10 peaks and their relative retention times along with the ranges of relative area were determined. The method is reliable and stable and can be used for the quality control and identification of Alpinia officinarum.

  19. [The qualitative analysis and quantitative analysis of purification of salvianolic acids by macroreticular resin].

    PubMed

    Fang, Xin-sheng; Tan, Xiao-mei

    2005-09-01

    To purify salvianolic acids by macroreticular resin,then mensurate the contents of salvianolic acids and analyse the chromatogram with HPLC. Make salvianolic acids with macroreticular resin; mensurate the content of Salvianolic acids with UV spestrophotometry: the control compound is protocaechuic aldehyde, and the wavelength is 281 nm. Analysis the chromatogram with HPLC, and compare the chromatogram in different technics: zorbax ODS column (4.6 mm x 250 mm, 5 microm), mobilephase: 1% aceticacid-water and methanol in different proportions, the wavelength is 281 nm. The contents of salvianolic acids is 53.8%; HPLC chromatogram indicate that the method is reasonable to make salvianolic acids. Determination of contents and HPLC chromatogram can control the quality of Salvianolic acids more accurately.

  20. [A semimicroquality evaluation method on Panax notoginseng and its application in analysis of continuous cropping obstacles research samples].

    PubMed

    Cao, Yi; Wang, Chao-Qun; Xu, Feng; Jia, Xiu-Hong; Liu, Guang-Xue; Yang, Sheng-Chao; Long, Guang-Qiang; Chen, Zhong-Jian; Wei, Fu-Zhou; Yang, Shao-Zhou; Fukuda, Kozo; Wang, Xuan; Cai, Shao-Qing

    2016-10-01

    Panax notoginseng is a commonly used traditional Chinese medicine with blood activating effect while has continuous cropping obstacle problem in planting process. In present study, a semimicroextraction method with water-saturated n-butanol on 0.1 g notoginseng sample was established with good repeatability (RSD<2.5%) and 9.6%-20.6% higher extraction efficiency of seven saponins than the conventional method. A total of 16 characteristic peaks were identified by LC-MS-IT-TOF, including eight 20(S)-protopanaxatriol (PPT) type saponins and eight 20(S)-protopanaxadiol (PPD) type saponins. The established method was utilized to evaluate the quality of notoginseng samples cultivated by manual intervened methods to overcome continuous cropping obstacles.As a result, HPLC fingerprint similarity, content of Fa and ratio of notoginsenoside K and notoginsenoside Fa (N-K/Fa) were found out to be as valuatable markers of the quality of samples in continuous cropping obstacle research, of which N-K/Fa could also be applied to the analysis of notoginseng samples with different growth years.Notoginseng samples with continuous cropping obstacle had HPLC fingerprint similarity lower than 0.87, in consistent with normal sample, and had significant lower content of notoginsenoside Fa and significant higher N-K/Fa (2.35-4.74) than normal group (0.45-1.33). All samples in the first group with manual intervention showed high similarity with normal group (>0.87), similar content of common peaks and N-K/Fa (0.42-2.06). The content of notoginsenoside K in the second group with manual intervention was higher than normal group. All samples except two displayed similarity higher than 0.87 and possessed content of 16 saponins close to normal group. The result showed that notoginseng samples with continuous cropping obstacle had lower quality than normal sample. And manual intervened methods could improve their quality in different levels.The method established in this study was simple, fast and accurate, and the markers may provide new guides for quality control in continuous cropping obstacle research of notoginseng. Copyright© by the Chinese Pharmaceutical Association.

  1. Simultaneous quantitative analysis of main components in linderae reflexae radix with one single marker.

    PubMed

    Wang, Li-Li; Zhang, Yun-Bin; Sun, Xiao-Ya; Chen, Sui-Qing

    2016-05-08

    Establish a quantitative analysis of multi-components by the single marker (QAMS) method for quality evaluation and validate its feasibilities by the simultaneous quantitative assay of four main components in Linderae Reflexae Radix. Four main components of pinostrobin, pinosylvin, pinocembrin, and 3,5-dihydroxy-2-(1- p -mentheneyl)- trans -stilbene were selected as analytes to evaluate the quality by RP-HPLC coupled with a UV-detector. The method was evaluated by a comparison of the quantitative results between the external standard method and QAMS with a different HPLC system. The results showed that no significant differences were found in the quantitative results of the four contents of Linderae Reflexae Radix determined by the external standard method and QAMS (RSD <3%). The contents of four analytes (pinosylvin, pinocembrin, pinostrobin, and Reflexanbene I) in Linderae Reflexae Radix were determined by the single marker of pinosylvin. This fingerprint was the spectra determined by Shimadzu LC-20AT and Waters e2695 HPLC that were equipped with three different columns.

  2. Reversed phase HPLC for strontium ranelate: Method development and validation applying experimental design.

    PubMed

    Kovács, Béla; Kántor, Lajos Kristóf; Croitoru, Mircea Dumitru; Kelemen, Éva Katalin; Obreja, Mona; Nagy, Előd Ernő; Székely-Szentmiklósi, Blanka; Gyéresi, Árpád

    2018-06-01

    A reverse-phase HPLC (RP-HPLC) method was developed for strontium ranelate using a full factorial, screening experimental design. The analytical procedure was validated according to international guidelines for linearity, selectivity, sensitivity, accuracy and precision. A separate experimental design was used to demonstrate the robustness of the method. Strontium ranelate was eluted at 4.4 minutes and showed no interference with the excipients used in the formulation, at 321 nm. The method is linear in the range of 20-320 μg mL-1 (R2 = 0.99998). Recovery, tested in the range of 40-120 μg mL-1, was found to be 96.1-102.1 %. Intra-day and intermediate precision RSDs ranged from 1.0-1.4 and 1.2-1.4 %, resp. The limit of detection and limit of quantitation were 0.06 and 0.20 μg mL-1, resp. The proposed technique is fast, cost-effective, reliable and reproducible, and is proposed for the routine analysis of strontium ranelate.

  3. An HPLC method for determination of azadirachtin residues in bovine muscle.

    PubMed

    Gai, María Nella; Álvarez, Christian; Venegas, Raúl; Morales, Javier

    2011-04-01

    A high-performance liquid chromatography (HPLC) method for the determination of azadirachtin (A and B) residues in bovine muscle has been developed. Azadirachtin is a neutral triterpene and chemotherapeutic agent effective in controlling some pest flies in horses, stables, horns and fruit. The actual HPLC method uses an isocratic elution and UV detection. Liquid-liquid extraction and solid-phase purification was used for the clean-up of the biological matrix. The chromatographic determination of these components is achieved using a C18 analytical column with water-acetonitrile mixture (27.5:72.5, v/v) as mobile phase, 1 mL/min as flow rate, 45 °C column temperature and UV detector at 215 nm. The azadirachtin peaks are well resolved and free of interference from matrix components. The extraction and analytical method developed in this work allows the quantitation of azadirachtin with precision and accuracy, establishing a lower limit of quantitation of azadirachtin, extracted from the biological matrix.

  4. HPLC-Based Method to Evaluate Kinetics of Glucosinolate Hydrolysis by Sinapis alba Myrosinase1

    PubMed Central

    Vastenhout, Kayla J.; Tornberg, Ruthellen H.; Johnson, Amanda L.; Amolins, Michael W.; Mays, Jared R.

    2014-01-01

    Isothiocyanates (ITCs) are one of several hydrolysis products of glucosinolates, plant secondary metabolites which are substrates for the thioglucohydrolase myrosinase. Recent pursuits toward the development of synthetic, non-natural ITCs have consequently led to an exploration of generating these compounds from non-natural glucosinolate precursors. Evaluation of the myrosinase-dependent conversion of select non-natural glucosinolates to non-natural ITCs cannot be accomplished using established UV-Vis spectroscopic methods. To overcome this limitation, an alternative HPLC-based analytical approach was developed where initial reaction velocities were generated from non-linear reaction progress curves. Validation of this HPLC method was accomplished through parallel evaluation of three glucosinolates with UV-Vis methodology. The results of this study demonstrate that kinetic data is consistent between both analytical methods and that the tested glucosinolates respond similarly to both Michaelis–Menten and specific activity analyses. Consequently, this work resulted in the complete kinetic characterization of three glucosinolates with Sinapis alba myrosinase, with results that were consistent with previous reports. PMID:25068719

  5. An automatic on-line 2,2-diphenyl-1-picrylhydrazyl-high performance liquid chromatography method for high-throughput screening of antioxidants from natural products.

    PubMed

    Lu, Yanzhen; Wu, Nan; Fang, Yingtong; Shaheen, Nusrat; Wei, Yun

    2017-10-27

    Many natural products are rich in antioxidants which play an important role in preventing or postponing a variety of diseases, such as cardiovascular and inflammatory disease, diabetes as well as breast cancer. In this paper, an automatic on-line 2,2-diphenyl-1-picrylhydrazyl-high performance liquid chromatography (DPPH-HPLC) method was established for antioxidants screening with nine standards including organic acids (4-hydroxyphenylacetic acid, p-coumaric acid, ferulic acid, and benzoic acid), alkaloids (coptisine and berberine), and flavonoids (quercitrin, astragalin, and quercetin). The optimal concentration of DPPH was determined, and six potential antioxidants including 4-hydroxyphenylacetic acid, p-coumaric acid, ferulic acid, quercitrin, astragalin, and quercetin, and three non-antioxidants including benzoic acid, coptisine, and berberine, were successfully screened out and validated by conventional DPPH radical scavenging activity assay. The established method has been applied to the crude samples of Saccharum officinarum rinds, Coptis chinensis powders, and Malus pumila leaves, consecutively. Two potential antioxidant compounds from Saccharum officinarum rinds and five potential antioxidant compounds from Malus pumila eaves were rapidly screened out. Then these seven potential antioxidants were purified and identified as p-coumaric acid, ferulic acid, phloridzin, isoquercitrin, quercetin-3-xyloside, quercetin-3-arabinoside, and quercetin-3-rhamnoside using countercurrent chromatography combined with mass spectrometry and their antioxidant activities were further evaluated by conventional DPPH radical scavenging assay. The activity result was in accordance with that of the established method. This established method is cheap and automatic, and could be used as an efficient tool for high-throughput antioxidant screening from various complex natural products. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Solubilization and Stability of Mitomycin C Solutions Prepared for Intravesical Administration.

    PubMed

    Myers, Alan L; Zhang, Yan-Ping; Kawedia, Jitesh D; Zhou, Ximin; Sobocinski, Stacey M; Metcalfe, Michael J; Kramer, Mark A; Dinney, Colin P N; Kamat, Ashish M

    2017-06-01

    Mitomycin C (MMC) is an antitumor agent that is often administered intravesically to treat bladder cancer. Pharmacologically optimized studies have suggested varying methods to optimize delivery, with drug concentration and solution volume being the main drivers. However, these MMC concentrations (e.g. 2.0 mg/mL) supersede its solubility threshold, raising major concerns of inferior drug delivery. In this study, we seek to confirm that the pharmacologically optimized MMC concentrations are achievable in clinical practice through careful modifications of the solution preparation methods. MMC admixtures (1.0 and 2.0 mg/mL) were prepared in normal saline using conventional and alternative compounding methods. Conventional methodology resulted in poorly soluble solutions, with many visible particulates and crystallates. However, special compounding methods, which included incubation of solutions at 50 °C for 50 min followed by storage at 37 °C, were sufficient to solubilize drug. Chemical degradation of MMC solutions was determined over 6 h using high-performance liquid chromatography (HPLC) analytics, while physical stability was tested in parallel. Immediately following the 50 min incubation, both MMC solutions exhibited approximately 5-7% drug degradation. Based on the measured concentrations and linear regression of degradation plots, additional storage of these solutions at 37 °C for 5 h retained chemical stability criterion (< 10% overall drug loss). No physical changes were observed in any solutions at any test time points. We recommend that the described alternative preparation methods may improve intravesicular delivery of MMC in this urological setting, and advise that clinicians employing these changes should closely monitor patients for MMC toxicities and pharmacodynamics (change in clinical outcomes) that result from the potential enhancement of MMC exposure in the bladder.

  7. A New Method for Xenogeneic Bone Graft Deproteinization: Comparative Study of Radius Defects in a Rabbit Model

    PubMed Central

    Lei, Pengfei; Sun, Rongxin; Wang, Long; Zhou, Jialin; Wan, Lifei; Zhou, Tianjian; Hu, Yihe

    2015-01-01

    Background and Objectives Deproteinization is an indispensable process for the elimination of antigenicity in xenograft bones. However, the hydrogen peroxide (H2O2) deproteinized xenograft, which is commonly used to repair bone defect, exhibits limited osteoinduction activity. The present study was designed to develop a new method for deproteinization and compare the osteogenic capacities of new pepsin deproteinized xenograft bones with those of conventional H2O2 deproteinized ones. Methods Bones were deproteinized in H2O2 or pepsin for 8 hours. The morphologies were compared by HE staining. The content of protein and collagen I were measured by the Kjeldahl method and HPLC-MS, respectively. The physical properties were evaluated by SEM and mechanical tests. For in vivo study, X-ray, micro-CT and HE staining were employed to monitor the healing processes of radius defects in rabbit models transplanted with different graft materials. Results Compared with H2O2 deproteinized bones, no distinct morphological and physical changes were observed. However, pepsin deproteinized bones showed a lower protein content, and a higher collagen content were preserved. In vivo studies showed that pepsin deproteinized bones exhibited better osteogenic performance than H2O2 deproteinized bones, moreover, the quantity and quality of the newly formed bones were improved as indicated by micro-CT analysis. From the results of histological examination, the newly formed bones in the pepsin group were mature bones. Conclusions Pepsin deproteinized xenograft bones show advantages over conventional H2O2 deproteinized bones with respect to osteogenic capacity; this new method may hold potential clinical value in the development of new biomaterials for bone grafting. PMID:26719896

  8. Determining Vitamin D Status: A Comparison between Commercially Available Assays

    PubMed Central

    Snellman, Greta; Melhus, Håkan; Gedeborg, Rolf; Byberg, Liisa; Berglund, Lars; Wernroth, Lisa; Michaëlsson, Karl

    2010-01-01

    Background Vitamin D is not only important for bone health but can also affect the development of several non-bone diseases. The definition of vitamin D insufficiency by serum levels of 25-hydroxyvitamin D depends on the clinical outcome but might also be a consequence of analytical methods used for the definition. Although numerous 25-hydroxyvitamin D assays are available, their comparability is uncertain. We therefore aim to investigate the precision, accuracy and clinical consequences of differences in performance between three common commercially available assays. Methodology/Principal Findings Serum 25-hydroxyvitamin D levels from 204 twins from the Swedish Twin Registry were determined with high-pressure liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (HPLC-APCI-MS), a radioimmunoassay (RIA) and a chemiluminescent immunoassay (CLIA). High inter-assay disagreement was found. Mean 25-hydroxyvitamin D levels were highest for the HPLC-APCI-MS technique (85 nmol/L, 95% CI 81–89), intermediate for RIA (70 nmol/L, 95% CI 66–74) and lowest with CLIA (60 nmol/L, 95% CI 56–64). Using a 50-nmol/L cut-off, 8% of the subjects were insufficient using HPLC-APCI-MS, 22% with RIA and 43% by CLIA. Because of the heritable component of 25-hydroxyvitamin D status, the accuracy of each method could indirectly be assessed by comparison of within-twin pair correlations. The strongest correlation was found for HPLC-APCI-MS (r = 0.7), intermediate for RIA (r = 0.5) and lowest for CLIA (r = 0.4). Regression analyses between the methods revealed a non-uniform variance (p<0.0001) depending on level of 25-hydroxyvitamin D. Conclusions/Significance There are substantial inter-assay differences in performance. The most valid method was HPLC-APCI-MS. Calibration between 25-hydroxyvitamin D assays is intricate. PMID:20644628

  9. Detection of Free Polyamines in Plants Subjected to Abiotic Stresses by High-Performance Liquid Chromatography (HPLC).

    PubMed

    Gong, Xiaoqing; Liu, Ji-Hong

    2017-01-01

    High-performance liquid chromatography (HPLC) is a sensitive, rapid, and accurate technique to detect and characterize various metabolites from plants. The metabolites are extracted with different solvents and eluted with appropriate mobile phases in a designed HPLC program. Polyamines are known to accumulate under abiotic stress conditions in various plant species and thought to provide protection against oxidative stress by scavenging reactive oxygen species. Here, we describe a common method to detect the free polyamines in plant tissues both qualitatively and quantitatively.

  10. Phenolic acids in the flowers of Althaea rosea var. nigra.

    PubMed

    Dudek, Marlena; Matławska, Irena; Szkudlarek, Maurycy

    2006-01-01

    Distribution of phenolic acids in the flowers of Althaea rosea var. nigra has been studied by 2D-TLC and HPLC methods. The phenolic acids occurring in these fractions have been identified as ferulic, vanillic, syringic, p-coumaric, p-hydroxybenzoic, p-hydroxyphenylacetic and caffeic acids. By means of the HPLC methods the contents of major phenolic acids were estimated. From among the phenolic acids analyzed the syringic, p-hydroxybenzoic and p-coumaric acids are dominant. Total content of phenolic acids was determined by the Arnov's method.

  11. Easy and Fast Method for the Determination of Biogenic Amines in Fish and Fish Products with Liquid Chromatography Coupled to Orbitrap Tandem Mass Spectrometry.

    PubMed

    Kaufmann, Anton; Maden, Kathryn

    2018-03-01

    A quantitative method for the determination of biogenic amines was developed. The method is characterized by the virtual absence of sample cleanup and does not require a derivatization reaction. Diluted extracts are centrifuged, filtrated, and directly injected into an ultra-HPLC column, which is coupled to a single-stage high-resolution mass spectrometer (Orbitrap). The chromatography is based on a reversed-phase column and an eluent containing an ion-pairing agent (heptafluorobutyric acid). The high sensitivity of the instrument permits the injection of very diluted extracts, which ensures stable retention times and the virtual absence of signal suppression effects. In addition, the quantification of histamine (a regulated compound) is further aided by the use of an isotopically labeled internal standard. The method was validated for three fish-based matrixes. Both the sample processing and the analytical measurement are very fast; hence, the methodology is ideal for high-throughput work. In addition, the method is significantly more selective than conventional methods (i.e., derivatization followed by LC with UV/fluorescence (FL) detection) for biogenic amines. A comparison showed that LC-UV/FL methods can produce false-positive findings due to coeluting matrix compounds.

  12. Determination of α-tocopherol by reversed-phase HPLC in feed and animal-derived foods without saponification.

    PubMed

    Claeys, Erik; Vossen, Els; De Smet, Stefaan

    2016-01-30

    The analysis of α-tocopherol in feed and animal-derived foods usually involves a saponification step. However, since saponification often leads to losses of α-tocopherol, a method for the determination of α-tocopherol in feed and in animal-derived foods was developed without a saponification step. In this method, α-tocopherol is extracted with hot ethanol and the co-extracted fat is removed by centrifugation. Removal of the fat fraction is made possible by the addition of water, to achieve an ethanol:water ratio of 40:7, followed by cooling on ice before centrifugation. This procedure allows removal of the fat fraction, while α-tocopherol is retained. Matrices differing in gross composition and α-tocopherol content were analyzed: fresh pork, cooked ham, subcutaneous fat, liver, egg yolk, milk and a compound pig feed. Higher α-tocopherol concentrations were found for this novel method compared to a conventional method with saponification, particularly for subcutaneous fat (P < 0.05). Recoveries were higher (P < 0.05) for the novel method (82-103%), compared to the saponification method (66-90%; for subcutaneous fat < 25%). Determining α-tocopherol in feed and animal-derived foods using pure ethanol without saponification results in higher extraction yields and recoveries compared to the saponification method. © 2015 Society of Chemical Industry.

  13. Automated on-line renewable solid-phase extraction-liquid chromatography exploiting multisyringe flow injection-bead injection lab-on-valve analysis.

    PubMed

    Quintana, José Benito; Miró, Manuel; Estela, José Manuel; Cerdà, Víctor

    2006-04-15

    In this paper, the third generation of flow injection analysis, also named the lab-on-valve (LOV) approach, is proposed for the first time as a front end to high-performance liquid chromatography (HPLC) for on-line solid-phase extraction (SPE) sample processing by exploiting the bead injection (BI) concept. The proposed microanalytical system based on discontinuous programmable flow features automated packing (and withdrawal after single use) of a small amount of sorbent (<5 mg) into the microconduits of the flow network and quantitative elution of sorbed species into a narrow band (150 microL of 95% MeOH). The hyphenation of multisyringe flow injection analysis (MSFIA) with BI-LOV prior to HPLC analysis is utilized for on-line postextraction treatment to ensure chemical compatibility between the eluate medium and the initial HPLC gradient conditions. This circumvents the band-broadening effect commonly observed in conventional on-line SPE-based sample processors due to the low eluting strength of the mobile phase. The potential of the novel MSFI-BI-LOV hyphenation for on-line handling of complex environmental and biological samples prior to reversed-phase chromatographic separations was assessed for the expeditious determination of five acidic pharmaceutical residues (viz., ketoprofen, naproxen, bezafibrate, diclofenac, and ibuprofen) and one metabolite (viz., salicylic acid) in surface water, urban wastewater, and urine. To this end, the copolymeric divinylbenzene-co-n-vinylpyrrolidone beads (Oasis HLB) were utilized as renewable sorptive entities in the micromachined unit. The automated analytical method features relative recovery percentages of >88%, limits of detection within the range 0.02-0.67 ng mL(-1), and coefficients of variation <11% for the column renewable mode and gives rise to a drastic reduction in operation costs ( approximately 25-fold) as compared to on-line column switching systems.

  14. Determination of N-glycans by high performance liquid chromatography using 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate as the glycosylamine labeling reagent.

    PubMed

    Wu, Yike; Sha, Qiuyue; Du, Juan; Wang, Chang; Zhang, Liang; Liu, Bi-Feng; Lin, Yawei; Liu, Xin

    2018-02-02

    Robust, efficient identification and accurate quantification of N-glycans are of great significance in N-glycomics analysis. Here, a simple and rapid derivatization method, based on the combination of microwave-assisted deglycosylation and 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) labeling, was developed for the analysis of N-glycan by high performance liquid chromatography with fluorescence detection (HPLC-FLD). After optimizing various parameters affecting deglycosylation and derivatization by RNase B, the time for N-glycan labeling was shortened to 50 min with ∼10-fold enhancement in detection sensitivity comparing to conventional 2-aminobenzoic acid (2-AA) labeling method. Additionally, the method showed good linearity (correlation coefficients > 0.991) and reproducibility (RSD < 8.7%). These advantages of the proposed method were further validated by the analysis of complex samples, including fetuin and human serum. Investigation of serum N-glycome for preliminary diagnosis of human lung cancer was conducted, where significant changes of several N-glycans corresponding to core-fucosylated, mono- and disialylated glycans have been evidenced by a series of statistical analysis. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Chemical and botanical characterization of Chilean propolis and biological activity on cariogenic bacteria Streptococcus mutans and Streptococcus sobrinus.

    PubMed

    Barrientos, Leticia; Herrera, Christian L; Montenegro, Gloria; Ortega, Ximena; Veloz, Jorge; Alvear, Marysol; Cuevas, Alejandro; Saavedra, Nicolás; Salazar, Luis A

    2013-01-01

    Propolis is a non-toxic natural substance with multiple pharmacological properties including anti-cancer, antioxidant, fungicidal, antibacterial, antiviral, and anti-inflammatory among others. The aim of this study was to determine the chemical and botanical characterization of Chilean propolis samples and to evaluate their biological activity against the cariogenic bacteria Streptococcus mutans and Streptococcus sobrinus. Twenty propolis samples were obtained from beekeeping producers from the central and southern regions of Chile. The botanical profile was determined by palynological analysis. Total phenolic contents were determined using colorimetric assays. Reverse phase HPLC and HPLC-MS were used to determine the chemical composition. The minimum inhibitory concentration (MIC) was determined on S. mutans and S. sobrinus. All propolis samples were dominated by structures from native plant species. The characterization by HPLC/MS, evidenced the presence of quercetin, myricetin, kaempferol, rutine, pinocembrin, coumaric acid, caffeic acid and caffeic acid phenethyl ester, that have already been described in these propolis with conventional HPLC. Although all propolis samples inhibited the mutans streptococci growth, it was observed a wide spectrum of action (MIC 0.90 to 8.22 μg mL(-1)). Given that results it becomes increasingly evident the need of standardization procedures, where we combine both the determination of botanical and the chemical characterization of the extracts. Research conducted to date, describes a promising effectiveness of propolis in the prevention of caries and other diseases of the oral cavity, making it necessary to develop studies to identify and understand the therapeutic targets or mechanisms of molecular action of the various compounds present on them.

  16. Simultaneous determination of vasicine and vasicinone by High-performance liquid chromatography in roots of eight Sida species.

    PubMed

    Subramanya, M D; Pai, Sandeep R; Ankad, Gireesh M; Hegde, Harsha V; Roy, Subarna; Hoti, S L

    2016-01-01

    Sida L. is a medicinally important genus widely used in conventional systems of medicine in India. The present study aims toward simultaneous determination of two bioactive compounds vasicine and vasicinone in root extracts of eight Sida spp. from Western Ghats, India. Determination of vasicine and vasicinone was undertaken in methanolic root extracts (10% w/v) of Sida acuta , Sida cordata , Sida cordifolia , Sida rhombifolia , Sida spinosa , Sida indica , Sida retusa and Sida mysorensis by high performance liquid chromatography (HPLC) method. The standards were prepared with the concentration of mg/mL. Data were expressed as mean values of three reading and relative standard deviations. The separation was achieved on a Waters, Nova-Pack, C18 (250 mm × 4.6 mm, 5 μ) column, with acetonitrile - 0.1 M phosphate buffer-glacial acetic acid (15: 85: 1, v/v/v) as solvent system at a flow-rate of 1.0 mL/min. The effluent was monitored using ultraviolet detection at a wavelength of 300 nm. Both calibration curves of standard showed good linear regression ( R 2 > 0.994). The limit of detection and the limit of quantification for vasicine was 0.110 and 0.333 μg/mL and for vasicinone was 0.059 and 0.179 μg/mL respectively. The vasicine content was highest in S. cordifolia (9.891 ± 0.495 μg/100 mg) and vasicinone content was rich in S. cordata (33.013 ± 1.651 μg/100 mg.) The content of vasicinone was higher than vasicine. HPLC method provides simple, accurate, and reproducible quantitative analysis for simultaneous determination of vasicine and vasicinone. Among the selected Sida species, S. cordifolia and S. cordata were found to be rich in the vasicine and vasicinone contents, respectively.

  17. A solid-phase extraction procedure coupled to 1H NMR, with chemometric analysis, to seek reliable markers of the botanical origin of honey.

    PubMed

    Beretta, Giangiacomo; Caneva, Enrico; Regazzoni, Luca; Bakhtyari, Nazanin Golbamaki; Maffei Facino, Roberto

    2008-07-14

    The aim of this work was to establish an analytical method for identifying the botanical origin of honey, as an alternative to conventional melissopalynological, organoleptic and instrumental methods (gas-chromatography coupled to mass spectrometry (GC-MS), high-performance liquid chromatography HPLC). The procedure is based on the (1)H nuclear magnetic resonance (NMR) profile coupled, when necessary, with electrospray ionisation-mass spectrometry (ESI-MS) and two-dimensional NMR analyses of solid-phase extraction (SPE)-purified honey samples, followed by chemometric analyses. Extracts of 44 commercial Italian honeys from 20 different botanical sources were analyzed. Honeydew, chestnut and linden honeys showed constant, specific, well-resolved resonances, suitable for use as markers of origin. Honeydew honey contained the typical resonances of an aliphatic component, very likely deriving from the plant phloem sap or excreted into it by sap-sucking aphids. Chestnut honey contained the typical signals of kynurenic acid and some structurally related metabolite. In linden honey the (1)H NMR profile gave strong signals attributable to the mono-terpene derivative cyclohexa-1,3-diene-1-carboxylic acid (CDCA) and to its 1-O-beta-gentiobiosyl ester (CDCA-GBE). These markers were not detectable in the other honeys, except for the less common nectar honey from rosa mosqueta. We compared and analyzed the data by multivariate techniques. Principal component analysis found different clusters of honeys based on the presence of these specific markers. The results, although obviously only preliminary, suggest that the (1)H NMR profile (with HPLC-MS analysis when necessary) can be used as a reference framework for identifying the botanical origin of honey.

  18. Quantification of free formaldehyde in carrageenan and processed Eucheuma seaweed using high-performance liquid chromatography.

    PubMed

    Hornshøj, Bettina Høj; Kobbelgaard, Sara; Blakemore, William R; Stapelfeldt, Henrik; Bixler, Harris J; Klinger, Markus

    2015-01-01

    In 2010 the European Commission placed a limit on the amount of free formaldehyde in carrageenan and processed Eucheuma seaweed (PES) of 5 mg kg(-1). Formaldehyde is not used in carrageenan and PES processing and accordingly one would not expect free formaldehyde to be present in carrageenan and PES. However, surprisingly high levels up to 10 mg kg(-1) have been found using the generally accepted AOAC and Hach tests. These findings are, per proposed reaction pathways, likely due to the formation of formaldehyde when sulphated galactose, the backbone of carrageenan, is hydrolysed with the strong acid used in these conventional tests. In order to minimise the risk of false-positives, which may lead to regulatory non-compliance, a new high-performance liquid chromatography (HPLC) method has been developed. Initially, carrageenan or PES is extracted with 2-propanol and subsequently reacted with 2,4-dinitrophenylhydrazine (DNPH) to form the chromophore formaldehyde-DNPH, which is finally quantified by reversed-phase HPLC with ultraviolet light detection at 355 nm. This method has been found to have a limit of detection of 0.05 mg kg(-1) and a limit of quantification of 0.2 mg kg(-1). Recoveries from samples spiked with known quantities of formaldehyde were 95-107%. Using this more specific technique, 20 samples of carrageenan and PES were tested for formaldehyde. Only one sample had a detectable content of formaldehyde (0.40 mg kg(-1)), thus demonstrating that the formaldehyde content of commercial carrageenan and PES products are well below the European Commission maximum limit of 5 mg kg(-1).

  19. High performance liquid chromatographic determination of caffeine in decaffeinated coffee, tea, and beverage products.

    PubMed

    Ashoor, S H; Seperich, G J; Monte, W C; Welty, J

    1983-05-01

    A method was developed for determining caffeine in decaffeinated coffee, tea, and beverage products by high performance liquid chromatography (HPLC). The HPLC system consisted of a Bio-Sil ODS-5S C18 column, methanol-water (25 + 75) mobile phase at 1 mL/min, and a UV detector. The method is simple and specific. Caffeine recoveries were 93.8-98.3% and coefficients of variation were 0.90-2.25%.

  20. New Stability Indicating RP-HPLC Method for the Estimation of Cefpirome Sulphate in Bulk and Pharmaceutical Dosage Forms.

    PubMed

    Rao, Kareti Srinivasa; Kumar, Keshar Nargesh; Joydeep, Datta

    2011-01-01

    A simple stability indicating reversed-phase HPLC method was developed and subsequently validated for estimation of Cefpirome sulphate (CPS) present in pharmaceutical dosage forms. The proposed RP-HPLC method utilizes a LiChroCART-Lichrosphere100, C18 RP column (250 mm × 4mm × 5 μm) in an isocratic separation mode with mobile phase consisting of methanol and water in the proportion of 50:50 % (v/v), at a flow rate 1ml/min, and the effluent was monitored at 270 nm. The retention time of CPS was 2.733 min and its formulation was exposed to acidic, alkaline, photolytic, thermal and oxidative stress conditions, and the stressed samples were analyzed by the proposed method. The described method was linear over a range of 0.5-200μg/ml. The percentage recovery was 99.46. F-test and t-test at 95% confidence level were used to check the intermediate precision data obtained under different experimental setups; the calculated value was found to be less than the critical value.

  1. Semi-preparative HPLC preparation and HPTLC quantification of tetrahydroamentoflavone as marker in Semecarpus anacardium and its polyherbal formulations.

    PubMed

    Aravind, S G; Arimboor, Ranjith; Rangan, Meena; Madhavan, Soumya N; Arumughan, C

    2008-11-04

    Application of modern scientific knowledge coupled with sensitive analytical technique is important for the quality evaluation and standardization of polyherbal formulations. Semecarpus anacardium, an important medicinal plant with wide medicinal properties, is frequently used in a large number of traditional herbal preparations. Tetrahydroamentoflavone (THA), a major bioactive biflavonoid was selected as a chemical marker of S. anacardium and RP-semi-preparative HPLC conditions were optimized for the isolation of tetrahydroamentoflavone. HPTLC analytical method was developed for the fingerprinting of S. anacardium flavonoids and quantification of tetrahydroamentoflavone. The method was validated in terms of their linearity, LOD, LOQ, precision and accuracy and compared with RP-HPLC-DAD method. The methods were demonstrated for the chemical fingerprinting of S. anacardium plant parts and some commercial polyherbal formulations and the amount of tetrahydroamentoflavone was quantified. HPTLC analysis showed that S. anacardium seed contained approximately 10 g kg(-1) of tetrahydroamentoflavone. The methods were able to identify and quantify tetrahydroamentoflavone from complex mixtures of phytochemicals and could be extended to the marker-based standardization of polyherbal formulations, containing S. anacardium.

  2. A single extraction and HPLC procedure for simultaneous analysis of phytosterols, tocopherols and lutein in soybeans.

    PubMed

    Slavin, Margaret; Yu, Liangli Lucy

    2012-12-15

    A saponification/extraction procedure and high performance liquid chromatography (HPLC) analysis method were developed and validated for simultaneous analysis of phytosterols, tocopherols and lutein (a carotenoid) in soybeans. Separation was achieved on a phenyl column with a ternary, isocratic solvent system of acetonitrile, methanol and water (48:22.5:29.5, v/v/v). Evaporative light scattering detection (ELSD) was used to quantify β-sitosterol, stigmasterol, campesterol, and α-, δ- and γ-tocopherols, while lutein was quantified with visible light absorption at 450 nm. Peak identification was verified by retention times and spikes with external standards. Standard curves were constructed (R(2)>0.99) to allow for sample quantification. Recovery of the saponification and extraction was demonstrated via analysis of spiked samples. Also, the accuracy of results of four soybeans using the described saponification and HPLC analytical method was validated against existing methods. This method offers a more efficient alternative to individual methods for quantifying lutein, tocopherols and sterols in soybeans. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. A validated solid-liquid extraction method for the HPLC determination of polyphenols in apple tissues Comparison with pressurised liquid extraction.

    PubMed

    Alonso-Salces, Rosa M; Barranco, Alejandro; Corta, Edurne; Berrueta, Luis A; Gallo, Blanca; Vicente, Francisca

    2005-02-15

    A solid-liquid extraction procedure followed by reversed-phase high-performance liquid chromatography (RP-HPLC) coupled with a photodiode array detector (DAD) for the determination of polyphenols in freeze-dried apple peel and pulp is reported. The extraction step consists in sonicating 0.5g of freeze-dried apple tissue with 30mL of methanol-water-acetic acid (30:69:1, v/v/v) containing 2g of ascorbic acid/L, for 10min in an ultrasonic bath. The whole method was validated, concluding that it is a robust method that presents high extraction efficiencies (peel: >91%, pulp: >95%) and appropriate precisions (within day: R.S.D. (n = 5) <5%, and between days: R.S.D. (n = 5) <7%) at the different concentration levels of polyphenols that can be found in apple samples. The method was compared with one previously published, consisting in a pressurized liquid extraction (PLE) followed by RP-HPLC-DAD determination. The advantages and disadvantages of both methods are discussed.

  4. Pungency Quantitation of Hot Pepper Sauces Using HPLC

    NASA Astrophysics Data System (ADS)

    Betts, Thomas A.

    1999-02-01

    A class of compounds known as capsaicinoids are responsible for the "heat" of hot peppers. To determine the pungency of a particular pepper or pepper product, one may quantify the capsaicinoids and relate those concentrations to the perceived heat. The format of the laboratory described here allows students to collectively develop an HPLC method for the quantitation of the two predominant capsaicinoids (capsaicin and dihydrocapsaicin) in hot-pepper products. Each small group of students investigated one of the following aspects of the method: detector wavelength, mobile-phase composition, extraction of capsaicinoids, calibration, and quantitation. The format of the lab forced students to communicate and cooperate to develop this method. The resulting HPLC method involves extraction with acetonitrile followed by solid-phase extraction clean-up, an isocratic 80:20 methanol-water mobile phase, a 4.6 mm by 25 cm C-18 column, and UV absorbance detection at 284 nm. The method developed by the students was then applied to the quantitation of capsaicinoids in a variety of hot pepper sauces. Editor's Note on Hazards in our April 2000 issue addresses the above.

  5. Stability-indicating HPLC-DAD methods for determination of two binary mixtures: Rabeprazole sodium-mosapride citrate and rabeprazole sodium-itopride hydrochloride.

    PubMed

    El-Fatatry, Hamed M; Mabrouk, Mokhtar M; Hewala, Ismail I; Emam, Ehab H

    2014-08-01

    Two selective stability-indicating HPLC methods are described for determination of rabeprazole sodium (RZ)-mosapride citrate (MR) and RZ-itopride hydrochloride (IO) mixtures in the presence of their ICH-stress formed degradation products. Separations were achieved on X-Bridge C18 column using two mobile phases: the first for RZ-MR mixture consisted of acetonitrile: 0.025 M KH 2 PO 4 solution: TEA (30:69:1 v/v; pH 7.0); the second for RZ-IO mixture was at ratio of 25:74:1 (v/v; pH 9.25). The detection wavelength was 283 nm. The two methods were validated and validation acceptance criteria were met in all cases. Peak purity testing using contrast angle theory, relative absorbance and log  A versus the wavelengths plots were presented. The % recoveries of the intact drugs were between 99.1% and 102.2% with RSD% values less than 1.6%. Application of the proposed HPLC methods indicated that the methods could be adopted to follow the stability of their formulations.

  6. Inulin determination for food labeling.

    PubMed

    Zuleta, A; Sambucetti, M E

    2001-10-01

    Inulin and oligofructose exhibit valuable nutritional and functional attributes, so they are used as supplements as soluble fiber or as macronutrient substitutes. As classic analytical methods for dietary fiber measurement are not effective, several specific methods have been proposed. These methods measure total fructans and are based on one or more enzymatic sample treatments and determination of released sugars. To determine inulin for labeling purposes, we developed an easy and rapid anion-exchange high-performance liquid chromatography (HPLC) method following water extraction of inulin. HPLC conditions included an Aminex HPX- 87C column (Bio-Rad), deionized water at 85 degrees C as the mobile phase and a refractive index detector. The tested foods included tailor-made food products containing known amounts of inulin and commercial products (cookies, milk, ice creams, cheese, and cereal bars). The average recovery was 97%, and the coefficient of variation ranged from 1.1 to 5% in the food matrixes. The obtained results showed that this method provides an easier, faster and cheaper alternative than previous techniques for determining inulin with enough accuracy and precision for routine labeling purposes by direct determination of inulin by HPLC with refractive index detection.

  7. Extraction and Determination of Cyproheptadine in Human Urine by DLLME-HPLC Method.

    PubMed

    Maham, Mehdi; Kiarostami, Vahid; Waqif-Husain, Syed; Abroomand-Azar, Parviz; Tehrani, Mohammad Saber; Khoeini Sharifabadi, Malihe; Afrouzi, Hossein; Shapouri, Mahmoudreza; Karami-Osboo, Rouhollah

    2013-01-01

    Novel dispersive liquid-liquid microextraction (DLLME), coupled with high performance liquid chromatography with photodiode array detection (HPLC-DAD) has been applied for the extraction and determination of cyproheptadine (CPH), an antihistamine, in human urine samples. In this method, 0.6 mL of acetonitrile (disperser solvent) containing 30 μL of carbon tetrachloride (extraction solvent) was rapidly injected by a syringe into 5 mL urine sample. After centrifugation, the sedimented phase containing enriched analyte was dissolved in acetonitrile and an aliquot of this solution injected into the HPLC system for analysis. Development of DLLME procedure includes optimization of some important parameters such as kind and volume of extraction and disperser solvent, pH and salt addition. The proposed method has good linearity in the range of 0.02-4.5 μg mL(-1) and low detection limit (13.1 ng mL(-1)). The repeatability of the method, expressed as relative standard deviation was 4.9% (n = 3). This method has also been applied to the analysis of real urine samples with satisfactory relative recoveries in the range of 91.6-101.0%.

  8. [Study on ethnic medicine quantitative reference herb,Tibetan medicine fruits of Capsicum frutescens as a case].

    PubMed

    Zan, Ke; Cui, Gan; Guo, Li-Nong; Ma, Shuang-Cheng; Zheng, Jian

    2018-05-01

    High price and difficult to get of reference substance have become obstacles to HPLC assay of ethnic medicine. A new method based on quantitative reference herb (QRH) was proposed. Specific chromatograms in fruits of Capsicum frutescens were employed to determine peak positions, and HPLC quantitative reference herb was prepared from fruits of C. frutescens. The content of capsaicin and dihydrocapsaicin in the quantitative control herb was determined by HPLC. Eleven batches of fruits of C. frutescens were analyzed with quantitative reference herb and reference substance respectively. The results showed no difference. The present method is feasible for quality control of ethnic medicines and quantitative reference herb is suitable to replace reference substances in assay. Copyright© by the Chinese Pharmaceutical Association.

  9. A sensitive determination method for carbendazim and thiabendazole in apples by solid-phase microextraction-high performance liquid chromatography with fluorescence detection.

    PubMed

    Hu, Yanxue; Yang, Xiumin; Wang, Chun; Zhao, Jin; Li, Weining; Wang, Zhi

    2008-03-01

    A new analytical method for the determination of carbendazim (MBC) and thiabendazole (TBZ) in apples is reported, based on solid-phase microextraction (SPME) coupling HPLC with fluorescence detection. The main SPME and HPLC experimental conditions were optimized. The apples were first blended and centrifuged. Then, an aliquot of the resulting solution was subjected to SPME on a 60 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibre for 35 min at room temperature with the solution being stirred at 1100 rev min(-1). The extracted pesticides on the SPME fibre were desorbed in the mobile phase into the SPME/HPLC interface for HPLC analysis. The method was linear over the range 0.01-1 mg kg(-1) in apples for both MBC and TBZ, with detection limits of 0.005 and 0.003 mg kg(-1) and correlation coefficients of 0.9995 and 0.9998, respectively. The average recoveries for MBC and TBZ were 91.5 and 92.3% with the relative standard deviations (RSD) of 4.7 and 4.1% at the 0.1 mg kg(-1) level, and 94.6 and 96.1% with RSD of 3.3 and 3.8% at the 0.5 mg kg(-1) level, respectively. The method is simple, sensitive, organic solvent-free and is suitable for the determination of MBC and TBZ in apples.

  10. Topiramate: A Review of Analytical Approaches for the Drug Substance, Its Impurities and Pharmaceutical Formulations.

    PubMed

    Pinto, Eduardo Costa; Dolzan, Maressa Danielli; Cabral, Lucio Mendes; Armstrong, Daniel W; de Sousa, Valéria Pereira

    2016-02-01

    An important step during the development of high-performance liquid chromatography (HPLC) methods for quantitative analysis of drugs is choosing the appropriate detector. High sensitivity, reproducibility, stability, wide linear range, compatibility with gradient elution, non-destructive detection of the analyte and response unaffected by changes in the temperature/flow are some of the ideal characteristics of a universal HPLC detector. Topiramate is an anticonvulsant drug mainly used for the treatment of different types of seizures and prophylactic treatment of migraine. Different analytical approaches to quantify topiramate by HPLC have been described because of the lack of chromophoric moieties on its structure, such as derivatization with fluorescent moieties and UV-absorbing moieties, conductivity detection, evaporative light scattering detection, refractive index detection, chemiluminescent nitrogen detection and MS detection. Some methods for the determination of topiramate by capillary electrophoresis and gas chromatography have also been published. This systematic review provides a description of the main analytical methods presented in the literature to analyze topiramate in the drug substance and in pharmaceutical formulations. Each of these methods is briefly discussed, especially considering the detector used with HPLC. In addition, this article presents a review of the data available regarding topiramate stability, degradation products and impurities. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Hydrothermal pretreatment of palm oil empty fruit bunch

    NASA Astrophysics Data System (ADS)

    Simanungkalit, Sabar Pangihutan; Mansur, Dieni; Nurhakim, Boby; Agustin, Astrid; Rinaldi, Nino; Muryanto, Fitriady, Muhammad Ariffudin

    2017-01-01

    Hydrothermal pretreatment methods in 2nd generation bioethanol production more profitable to be developed, since the conventional pretreatment, by using acids or alkalis, is associated with the serious economic and environmental constraints. The current studies investigate hydrothermal pretreatment of palm oil empty fruit bunch (EFB) in a batch tube reactor system with temperature and time range from 160 to 240 C and 15 to 30 min, respectively. The EFB were grinded and separated into 3 different particles sizes i.e. 10 mesh, 18 mesh and 40 mesh, prior to hydrothermal pretreatment. Solid yield and pH of the treated EFB slurries changed over treatment severities. The chemical composition of EFB was greatly affected by the hydrothermal pretreatment especially hemicellulose which decreased at higher severity factor as determined by HPLC. Both partial removal of hemicellulose and migration of lignin during hydrothermal pretreatment caused negatively affect for enzymatic hydrolysis. This studies provided important factors for maximizing hydrothermal pretreatment of EFB.

  12. Removal of caffeine from industrial wastewater using Trichosporon asahii.

    PubMed

    Lakshmi, V; Das, Nilanjana

    2013-07-01

    Caffeine (1,3,7-trimethylxanthine), a natural alkaloid present mainly in tea and coffee products has been suggested as an environmental pollutant. Decaffeination is an important process for the removal of caffeine from coffee industrial wastes. In the present study, caffeine removal (through degradation) by yeast isolate, Trichosporon asahii immobilized on various conventional matrices (sodium alginate, carboxymethyl cellulose, chitosan, agar and agarose) was investigated using the method of entrapment. The biofilm forming ability of T. asahii was monitored by atomic force microscopy and scanning electron microscopy. Exopolysaccharide produced by T asahii biofilm was characterized by FT-IR spectroscopy and HPLC analysis. Caffeine removal from coffee processing industrial effluent was found to be 75 and 80 % by alginate immobilized yeast and yeast biofilm formed on gravels over a period of 48 hr in batch mode. Effectiveness of the process was also tested involving the continuous--flow column studies.

  13. Evaluation of a direct injection nebulizer interface for flow injection analysis and high performance liquid chromatography with inductively coupled plasma-atomic emission spectroscopic detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LaFreniere, K.E.

    A direct injection nebulizer (DIN) was designed, developed and evaluated to determine its potential utilization as an effective interface for flow injection analysis (FIA) and high performance liquid chromatography (HPLC) coupled with inductively coupled plasma-atomic emission spectroscopic detection. The analytical figures of merit for the DIN when used as an interface for FIA-ICP-AES were found to be comparable to or better than those obtained with conventional pneumatic nebulization in terms of limits of detection (LODs), reproducibility, linearity, and interelement effects. In the HPLC mode, the LODDs were found to be comparable to those obtained by continuous-flow sample introduction into themore » ICP, or inferior by up to only a factor of four. Stable plasma operation was maintained for the DIN sample introduction of a variety of pure organic solvents, including acetonitrile, methanol, methyl-isobutylketone, and pyridine. The HPLC-DIN-ICP-AES facility was specifically applied for the speciation of inorganic and organo-metallic species contained in synthetic mixtures, vanilla extracts and a variety of energy-related materials, such as shale oil process water, coal extracts, shale oil, crude oil, and an SRC II. Suggestions for future research are also considered.« less

  14. Method development in high-performance liquid chromatography for high-throughput profiling and metabonomic studies of biofluid samples.

    PubMed

    Pham-Tuan, Hai; Kaskavelis, Lefteris; Daykin, Clare A; Janssen, Hans-Gerd

    2003-06-15

    "Metabonomics" has in the past decade demonstrated enormous potential in furthering the understanding of, for example, disease processes, toxicological mechanisms, and biomarker discovery. The same principles can also provide a systematic and comprehensive approach to the study of food ingredient impact on consumer health. However, "metabonomic" methodology requires the development of rapid, advanced analytical tools to comprehensively profile biofluid metabolites within consumers. Until now, NMR spectroscopy has been used for this purpose almost exclusively. Chromatographic techniques and in particular HPLC, have not been exploited accordingly. The main drawbacks of chromatography are the long analysis time, instabilities in the sample fingerprint and the rigorous sample preparation required. This contribution addresses these problems in the quest to develop generic methods for high-throughput profiling using HPLC. After a careful optimization process, stable fingerprints of biofluid samples can be obtained using standard HPLC equipment. A method using a short monolithic column and a rapid gradient with a high flow-rate has been developed that allowed rapid and detailed profiling of larger numbers of urine samples. The method can be easily translated into a slow, shallow-gradient high-resolution method for identification of interesting peaks by LC-MS/NMR. A similar approach has been applied for cell culture media samples. Due to the much higher protein content of such samples non-porous polymer-based small particle columns yielded the best results. The study clearly shows that HPLC can be used in metabonomic fingerprinting studies.

  15. Chromatographic methods for determination of S-substituted cysteine derivatives--a comparative study.

    PubMed

    Kubec, Roman; Dadáková, Eva

    2009-10-09

    A novel HPLC method for determination of a wide variety of S-substituted cysteine derivatives in Allium species has been developed and validated. This method allows simultaneous separation and quantification of S-alk(en)ylcysteine S-oxides, gamma-glutamyl-S-alk(en)ylcysteines and gamma-glutamyl-S-alk(en)ylcysteine S-oxides in a single run. The procedure is based on extraction of these amino acids and dipeptides by methanol, their derivatization by dansyl chloride and subsequent separation by reversed phase HPLC. The main advantages of the new method are simplicity, excellent stability of derivatives, high sensitivity, specificity and the ability to simultaneously analyze the whole range of S-substituted cysteine derivatives. This method was critically compared with other chromatographic procedures used for quantification of S-substituted cysteine derivatives, namely with two other HPLC methods (derivatization by o-phthaldialdehyde/tert-butylthiol and fluorenylmethyl chloroformate), and with determination by gas chromatography or capillary electrophoresis. Major advantages and drawbacks of these analytical procedures are discussed. Employing these various chromatographic methods, the content and relative proportions of individual S-substituted cysteine derivatives were determined in four most frequently consumed alliaceous vegetables (garlic, onion, shallot, and leek).

  16. Olive oil polyphenols: A quantitative method by high-performance liquid-chromatography-diode-array detection for their determination and the assessment of the related health claim.

    PubMed

    Ricciutelli, Massimo; Marconi, Shara; Boarelli, Maria Chiara; Caprioli, Giovanni; Sagratini, Gianni; Ballini, Roberto; Fiorini, Dennis

    2017-01-20

    In order to assess if an extra virgin olive oil (EVOO) can be acknowledged with the health claim related to olive oil polyphenols (Reg. EU n.432/2012), a new method to quantify these species in EVOO, by means of liquid-liquid extraction followed by HPLC-DAD/MS/MS of the hydroalcoholic extract, has been developed and validated. Different extraction procedures, different types of reverse-phase analytical columns (Synergi Polar, Spherisorb ODS2 and Kinetex) and eluents have been tested. The chromatographic column Synergi Polar (250×4.6mm, 4μm), never used before in this kind of application, provided the best results, with water and methanol/isopropanol (9/1) as eluents. The method allows the quantification of the phenolic alcohols tyrosol and hydroxytyrosol, the phenolic acids vanillic, p-coumaric and ferulic acids, secoiridoids derivatives, the lignans, pinoresinol and acetoxypinoresinol and the flavonoids luteolin and apigenin. The new method has been applied to 20 commercial EVOOs belonging to two different price range categories (3.78-5.80 euros/L and 9.5-25.80 euros/L) and 5 olive oils. The obtained results highlight that acetoxypinoresinol, ferulic acid, vanillic acid and the total non secoiridoid phenolic substances resulted to be significantly higher in HEVOOs than in LEVOOs (P=0.0026, 0.0217, 0.0092, 0.0003 respectively). For most of the samples analysed there is excellent agreement between the results obtained by applying the HPLC method adopted by the International Olive Council and the results obtained by applying the presented HPLC method. Results obtained by HPLC methods have been also compared with the ones obtained by the colorimetric Folin-Ciocalteu method. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Development and validation of reverse phase high performance liquid chromatography for citral analysis from essential oils.

    PubMed

    Gaonkar, Roopa; Yallappa, S; Dhananjaya, B L; Hegde, Gurumurthy

    2016-11-15

    Citral is a widely used monoterpene aldehyde in aromatherapy, food and pesticide industries. A new validated reverse phase high performance liquid chromatography (RP - HPLC) procedure for the detection and quantification of cis-trans isomers of citral was developed. The RP-HPLC analysis was carried out using Enable C - 18G column (250×4.6mm, 5μ), with acetonitrile and water (70: 30) mobile phase in isocratic mode at 1mL/min flow. A photodiode array (PDA) detector was set at 233nm for the detection of citral. The method showed linearity, selectivity and accuracy for citral in the range of 3-100μg/mL. In order to compare the new RP-HPLC method with the available methods, one of the commercially available essential oil from Cymbopogon flexuosus was analyzed using new RP-HPLC method and the same was analyzed using GC-MS for the comparison of the method for the detection of citral. The GC-MS analysis was done using mass selective detector (MSD) showed citral content to be of 72.76%; wherein the new method showed to contain that same at 74.98%. To prove the application of the new method, essential oils were extracted from lemongrass, lemon leaves and mosambi peels by steam distillation. The citral content present in the essential and also in the condensate was analyzed. The method was found to be suitable for the analysis of citral in essential oils and water based citral formulations with a very good resolution of its components geranial and neral. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Aqueous Reversed-Phase HPLC/FT-IR Using Diffuse Reflectance Detections

    NASA Astrophysics Data System (ADS)

    Kalasinsky, Victor F.; Pai, T. H.; Kenton, R. C.; Kalasinsky, Kathryn S.

    1989-12-01

    Solvent-elimination HPLC/FT-IR has become a viable combination of two important techniques, and we have been developing a system which is adaptable to both normal and reversed-phase liquid chromatography. The interface involves the deposition of HPLC eluites onto a KCI-laden train with subsequent analysis via diffuse reflectance spectroscopy, and with minor modifications, the system can be used with microbore and analytical columns. With aqueous solvents, the water is converted to methanol and acetone in a post-column reaction with 2,2-dimethoxypropane before the eluites are deposited. A number of different samples have been used to demonstrate the interface and its flexibility. Steroids, analgesics, and other pharmaceutical preparations have been separated with reverse-phase solvents and identified by their infrared spectra. For some of the compounds studied, different infrared spectra of a given compound have been found to exhibit intensity variations, which arise from different crystalline states. The differences can be concentration dependent and may be useful in obtaining semi-quantitative information from the infrared spectra. Applications involving both gradient elution and isocratic separations have been successful. The former provides the same advantages for HPLC/FT-IR as one finds in conventional HPLC. More recent work has been applied to the use of buffers such as those frequently used in bioanalytical separations. In trying to simplify the post-column reaction with water, we have immobilized dehydration reagents onto silica particles and packed these materials into a column which is inserted in-line after the analytical column. Of the reagents utilized to date, 3,3-dimethoxypropyltrimethoxysilane has been found to perform most efficiently. It has advantages over the simpler reagents because it can be regenerated in the reaction column. Results and the efficiency of the dehydration process and its relation to the type of reagent and its coverage will be discussed.

  19. RP-HPLC Determination of Phenylalkanoids and Monoterpenoids in Rhodiola rosea and Identification by LC-ESI-TOF

    USDA-ARS?s Scientific Manuscript database

    An HPLC method permitting the simultaneous determination of fourteen compounds (phenylalkanoids and monoterpenoids) from the roots of Rhodiola rosea was developed. A separation was achieved within 35 minutes by using C-18 column material, a water/acetonitrile mobile phase, both containing 0.05% phos...

  20. 76 FR 21700 - Notice of Request for Extension and Revision of a Currently Approved Collection

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-18

    ... analyses has its own methodology and time necessary to perform the analyses. (3) Aflatoxin in Pistachios Program (A High Performance Liquid Chromatography (HPLC) method for exporting pistachios to European Union requested by the California Pistachio Committee) and the domestic program using HPLC or a test kit analysis...

  1. Reverse-phase HPLC analysis of human alpha crystallin.

    PubMed

    Swamy, M S; Abraham, E C

    1991-03-01

    A rapid and highly sensitive reverse-phase HPLC (RP-HPLC) method was used to separate crystallin subunits from human alpha crystallin. Three distinct peaks were separated; by electrophoretic and immunological analyses the first and second peaks were identified as alpha B and alpha A respectively. On the other hand, peak 3 appeared to be a modified form of alpha crystallin. The ratio of alpha A and alpha B proteins was 3:1 in 1 day old lenses which gradually changed to 2:1 in 17 year old lenses and to 1:1 in the 50 and 82 year old whole lenses and 82 year old lens cortex, with a concomitant increase in the modified alpha, suggesting that alpha A subunits are relatively more involved in aggregation. Analysis of the 82 year old lens nucleus also supported this conclusion. The RP-HPLC analysis of the HMW aggregate fraction showed substantial enrichment of the modified alpha. The alpha A and alpha B subunits independently reassociated to form polymeric alpha crystallin whereas the modified alpha reassociated to form HMW aggregates as shown by molecular sieve HPLC. Hence it appears that the HMW aggregate peak was constituted by modified alpha crystallin. Only in the peak 3 material the 280 nm absorbance was about 2-fold higher than what was expected from the actual protein content. The data suggest that the changes induced by post-translational modifications may have some role in the formation of modified alpha. The present RP-HPLC method is useful in separating these modified alpha from the unmodified alpha A and alpha B subunits.

  2. Root Cause Analysis of Quality Defects Using HPLC-MS Fingerprint Knowledgebase for Batch-to-batch Quality Control of Herbal Drugs.

    PubMed

    Yan, Binjun; Fang, Zhonghua; Shen, Lijuan; Qu, Haibin

    2015-01-01

    The batch-to-batch quality consistency of herbal drugs has always been an important issue. To propose a methodology for batch-to-batch quality control based on HPLC-MS fingerprints and process knowledgebase. The extraction process of Compound E-jiao Oral Liquid was taken as a case study. After establishing the HPLC-MS fingerprint analysis method, the fingerprints of the extract solutions produced under normal and abnormal operation conditions were obtained. Multivariate statistical models were built for fault detection and a discriminant analysis model was built using the probabilistic discriminant partial-least-squares method for fault diagnosis. Based on multivariate statistical analysis, process knowledge was acquired and the cause-effect relationship between process deviations and quality defects was revealed. The quality defects were detected successfully by multivariate statistical control charts and the type of process deviations were diagnosed correctly by discriminant analysis. This work has demonstrated the benefits of combining HPLC-MS fingerprints, process knowledge and multivariate analysis for the quality control of herbal drugs. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Combined microplate-ABTS and HPLC-ABTS analysis of tomato and pepper extracts reveals synergetic and antagonist effects of their lipophilic antioxidative components.

    PubMed

    Le Grandois, Julie; Guffond, Delphine; Hamon, Erwann; Marchioni, Eric; Werner, Dalal

    2017-05-15

    The antioxidant capacity of 9 pure lipophilic compounds was examined by microplate-ABTS and HPLC-ABTS, using similar experimental conditions. Results obtained showed that HPLC-ABTS method can be used for a rapid determination of individual antioxidant capacity of compounds in standard solutions or complex mixtures. The application of both methods to real lipophilic extracts from tomato (Solanum lycopersicum L.), green and red peppers (Capsicum annuum) reveals possible interactions between antioxidants. Thus, synthetic mixtures of two compounds identified in tomato and peppers were measured using microplate-ABTS and HPLC-ABTS. Synergistic effects were observed between (β-carotene-capsanthin) (1:9) and (1:1), (α-tocopherol-capsanthin) (1:9), (lutein-lycopene) (9:1) and (capsanthin-δ-tocopherol) (9:1). On the contrary, antagonistic effects were observed for (lutein-δ-tocopherol) and (α-tocopherol-δ-tocopherol). The interactions observed with two-compound mixtures are not systematically observed in the natural lipophilic extracts from tomato, green and red peppers, probably since extracts are more complex and are susceptible to cause interferences. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. HPLC purification and re-evaluation of chemical identity of two circular bacteriocins, gassericin A and reutericin 6.

    PubMed

    Arakawa, K; Kawai, Y; Ito, Y; Nakamura, K; Chujo, T; Nishimura, J; Kitazawa, H; Saito, T

    2010-04-01

    The study aimed for the complete purification and recharacterization of the highly hydrophobic circular bacteriocins, gassericin A and reutericin 6. Gassericin A and reutericin 6 were purified to homogeneity using previously described method and reverse-phase HPLC with an octyl column and eluents of aqueous acetonitrile and 2-propanol. Mass analysis, N-terminal sequencing and bacteriocin assay of the HPLC-purified bacteriocins showed the two bacteriocins had identical seamless circular structures with the same m/z value (5651) of [M + H](+) and both had the same specific activity. D/L-amino acid composition analysis using two distinct methods with the chiral fluorescent derivatization reagents (+)-1-(9-fluorenyl)ethyl chloroformate and O-phthalaldehyde/N-acetyl-L-cystein revealed neither gassericin A nor reutericin 6 contained D-alanine residues contrary to our previous results. Purified gassericin A and reutericin 6 are chemically identical circular molecules containing no D-alanine residues. The HPLC conditions developed in this study will facilitate advanced purification and correct characterization of other highly hydrophobic bacteriocins.

  5. Preparative separation of grape skin polyphenols by high-speed counter-current chromatography.

    PubMed

    Luo, Lanxin; Cui, Yan; Zhang, Shuting; Li, Lingxi; Li, Yuanyuan; Zhou, Peiyu; Sun, Baoshan

    2016-12-01

    To develop an efficient method for large preparation of various individual polyphenols from white grape skins (Fernão Pires; Vitis vinifera) by preparative high-speed counter-current chromatography (HSCCC) and preparative-HPLC, an optimized preparative HSCCC condition with two-phase solvent system composed of Hex-EtOAc-H2O (1:50:50, v/v) was used to separate grape skin polyphenols into various fractions. Both the tail-head and head-tail elution modes were used with a flow rate of 3.0ml/min and a rotary speed of 950rpm. Afterwards, a preparative-HPLC separation was applied to isolate individual polyphenols in each of the fractions from HSCCC. Total of 7 fractions (Fraction A to G) were obtained from grape skin extract by HSCCC. After preparative-HPLC isolation, fifteen individual compounds were obtained, most of which presented high yields and purity (all over 90%). The HSCCC method followed with preparative-HPLC appeared to be convenient and economical, constituting an efficient strategy for the isolation of grape skin polyphenols. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Industrial application of green chromatography--I. Separation and analysis of niacinamide in skincare creams using pure water as the mobile phase.

    PubMed

    Yang, Yu; Strickland, Zackary; Kapalavavi, Brahmam; Marple, Ronita; Gamsky, Chris

    2011-03-15

    In this work, chromatographic separation of niacin and niacinamide using pure water as the sole component in the mobile phase has been investigated. The separation and analysis of niacinamide have been optimized using three columns at different temperatures and various flow rates. Our results clearly demonstrate that separation and analysis of niacinamide from skincare products can be achieved using pure water as the eluent at 60°C on a Waters XTerra MS C18 column, a Waters XBridge C18 column, or at 80°C on a Hamilton PRP-1 column. The separation efficiency, quantification quality, and analysis time of this new method are at least comparable with those of the traditional HPLC methods. Compared with traditional HPLC, the major advantage of this newly developed green chromatography technique is the elimination of organic solvents required in the HPLC mobile phase. In addition, the pure water chromatography separations described in this work can be directly applied in industrial plant settings without further modification of the existing HPLC equipment. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Improved Quantitation of Gluten in Wheat Starch for Celiac Disease Patients by Gel-Permeation High-Performance Liquid Chromatography with Fluorescence Detection (GP-HPLC-FLD).

    PubMed

    Scherf, Katharina Anne; Wieser, Herbert; Koehler, Peter

    2016-10-12

    Purified wheat starch (WSt) is commonly used in gluten-free products for celiac disease (CD) patients. It is mostly well-tolerated, but doubts about its safety for CD patients persist. One reason may be that most ELISA kits primarily recognize the alcohol-soluble gliadin fraction of gluten, but insufficiently target the alcohol-insoluble glutenin fraction. To address this problem, a new sensitive method based on the sequential extraction of gliadins, glutenins, and gluten from WSt followed by gel-permeation high-performance liquid chromatography with fluorescence detection (GP-HPLC-FLD) was developed. It revealed that considerable amounts of glutenins were present in most WSt. The gluten contents quantitated by GP-HPLC-FLD as sum of gliadins and glutenins were higher than those by R5 ELISA (gluten as gliadin content multiplied by a factor of 2) in 19 out of 26 WSt. Despite its limited selectivity, GP-HPLC-FLD may be applied as confirmatory method to ELISA to quantitate gluten in WSt.

  8. Chemical fingerprint and metabolic profile analysis of Citrus reticulate 'Chachi' decoction by HPLC-PDA-IT-MS(n) and HPLC-Quadrupole-Orbitrap-MS method.

    PubMed

    Ye, Xiaolan; Cao, Di; Zhao, Xin; Song, Fenyun; Huang, Qinghua; Fan, Guorong; Wu, Fuhai

    2014-11-01

    A method incorporating HPLC-PDA-IT-MS(n) with HPLC-Quadrupole-Orbitrap-MS was developed for the investigation of chemical fingerprint of Citrus reticulate 'Chachi' decoction (CRCD) and metabolic profile of SD rat plasma sample after oral administration of CRCD (1.5 g herb/kg). A total of 27 chemical constituents of CRCD were identified from their MW, UV spectra, MS(n) data and retention behavior by comparing the results with those of the reference standards or literature. And 43 compounds were detected in dosed SD rat plasma samples, including 9 prototypes which were identified as hesperetin, isosinensetin, sinensetin, tetramethyl-O-isoscutellarein, nobiletin, tetramethyl-O-scutellarein, HMF (3,5,6,7,8,3',4'-heptamethoxyflavone), tangeretin and 5-demethylnobiletin and 34 metabolites underwent metabolic process of demethylation, glucuronide conjugation, sulfate conjugation or mixed modes. This is the first research for the metabolic profile of CRCD in SD rats, which could lay a foundation for the further studies of CRC or its formulation. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. A Simple and Rapid HPLC-PDA MS Method for the Profiling of Citrus Peels and Traditional Italian Liquors.

    PubMed

    Guccione, Clizia; Bergonzi, Maria Camilla; Piazzini, Vieri; Bilia, Anna Rita

    2016-07-01

    A chromatographic method for the qualitative and quantitative characterization of peels and preparations based on different species of Citrus was developed in order to obtain a complete profile of the constituents, including flavonoids and protoalkaloids. Commercial peels of sweet orange, lemon, mandarin, and grapefruit were analyzed. Seventeen constituents including flavanones, flavones, polymethoxyflavones, and protoalkaloids were identified by HPLC-PDA, HPLC-MS, and HPLC-MS/MS using a comparison of retention times and UV-Vis and MS spectra with reference standards and literature data. The total amount of flavanones [neoeriocitrin (5), naringin (8) and hesperidin (9)] and polymethoxflavones [sinensetin (12), nobiletin (14), 3,5,6,7,8,3',4'-heptamethoxyflavone (15), and tangeretin (16)] was determined and expressed as naringin (8) or hesperidin (9), and sinensetin (12), respectively. The protoalkaloid synephrine was detected in all samples, except in grapefruit, but its content was lower than the limit of quantification. Qualitative and quantitative chemical profiles of three different Italian aromatic liquors ("Limoncello", "Arancello", and "Mandarinetto"), prepared according to traditional recipes, were also analyzed. Georg Thieme Verlag KG Stuttgart · New York.

  10. Amino acid ionic liquids as chiral ligands in ligand-exchange chiral separations.

    PubMed

    Liu, Qian; Wu, Kangkang; Tang, Fei; Yao, Lihua; Yang, Fei; Nie, Zhou; Yao, Shouzhuo

    2009-09-28

    Recently, amino acid ionic liquids (AAILs) have attracted much research interest. In this paper, we present the first application of AAILs in chiral separation based on the chiral ligand exchange principle. By using 1-alkyl-3-methylimidazolium L-proline (L-Pro) as a chiral ligand coordinated with copper(II), four pairs of underivatized amino acid enantiomers-dl-phenylalanine (dl-Phe), dl-histidine (dl-His), dl-tryptophane (dl-Trp), and dl-tyrosine (dl-Tyr)-were successfully separated in two major chiral separation techniques, HPLC and capillary electrophoresis (CE), with higher enantioselectivity than conventionally used amino acid ligands (resolution (R(s))=3.26-10.81 for HPLC; R(s)=1.34-4.27 for CE). Interestingly, increasing the alkyl chain length of the AAIL cation remarkably enhanced the enantioselectivity. It was inferred that the alkylmethylimidazolium cations and L-Pro form ion pairs on the surface of the stationary phase or on the inner surface of the capillary. The ternary copper complexes with L-Pro are consequently attached to the support surface, thus inducing an ion-exchange type of retention for the dl-enantiomers. Therefore, the AAIL cation plays an essential role in the separation. This work demonstrates that AAILs are good alternatives to conventional amino acid ligands for ligand-exchange-based chiral separation. It also reveals the tremendous application potential of this new type of task-specific ILs.

  11. FIXED DOSE COMBINATIONS WITH SELECTIVE BETA-BLOCKERS: QUANTITATIVE DETERMINATION IN BIOLOGICAL FLUIDS.

    PubMed

    Mahu, Ştefania Corina; Hăncianu, Monica; Agoroaei, Luminiţa; Grigoriu, Ioana Cezara; Strugaru, Anca Monica; Butnaru, Elena

    2015-01-01

    Hypertension is one of the most common causes of death, a complex and incompletely controlled disease for millions of patients. Metoprolol, bisoprolol, nebivolol and atenolol are selective beta-blockers frequently used in the management of arterial hypertension, alone or in fixed combination with other substances. This study presents the most used analytical methods for simultaneous determination in biological fluids of fixed combinations containing selective beta-blockers. Articles in Pub-Med, Science Direct and Wiley Journals databases published between years 2004-2014 were reviewed. Methods such as liquid chromatography--mass spectrometry--mass spectrometry (LC-MS/MS), high performance liquid chromatography (HPLC) or high performance liquid chromatography--mass spectrometry (HPLC-MS) were used for determination of fixed combination with beta-blockers in human plasma, rat plasma and human breast milk. LC-MS/MS method was used for simultaneous determination of fixed combinations of metoprolol with simvastatin, hydrochlorothiazide or ramipril, combinations of nebivolol and valsartan, or atenolol and amlodipine. Biological samples were processed by protein precipitation techniques or by liquid-liquid extraction. For the determination of fixed dose combinations of felodipine and metoprolol in rat plasma liquid chromatography--electrospray ionization--mass spectrometry (LC-ESI-MS/MS) was applied, using phenacetin as internal standard. HPLC-MS method was applied for the determination of bisoprolol and hydrochlorothiazide in human plasma. For the determination of atenolol and chlorthalidone from human breast milk and human plasma the HPLC method was used. The analytical methods were validated according to the specialized guidelines, and were applied to biological samples, thing that confirms the permanent concern of researchers in this field.

  12. Simultaneous analysis of eight bioactive compounds in Danning tablet by HPLC-ESI-MS and HPLC-UV.

    PubMed

    Liu, Runhui; Zhang, Jiye; Liang, Mingjin; Zhang, Weidong; Yan, Shikai; Lin, Min

    2007-02-19

    A high performance liquid chromatography (HPLC) coupled with electrospray tandem mass spectrometry (ESI-MS) and ultraviolet detector (UV) has been developed for the simultaneous analysis of eight bioactive compounds in Danning tablet (including hyperin, hesperidin, resveratrol, nobiletin, curcumine, emodin, chrysophanol, and physcion), a widely used prescription of traditional Chinese medicine (TCM). The chromatographic separation was performed on a ZORBAX Extend C(18) analytical column by gradient elution with acetonitrile and formate buffer (containing 0.05% formic acid, adjusted with triethylamine to pH 5.0) at a flow rate of 0.8 ml/min. The eight compounds in Danning tablet were identified and their MS(n) fractions were elucidated by using HPLC-ESI-MS, and the contents of these compounds were determined by using HPLC-UV method. The standard calibration curves were linear between 5.0 and 100 microg/ml for hyperin, 10-200 microg/ml for hesperidin, 1.0-150 microg/ml for resveratrol, 2.0-120 microg/ml for nobiletin, 2.0-225 microg/ml for curcumine, 20-300 microg/ml for emodin, 2.0-200 microg/ml for chrysophanol, and 20-250 microg/ml for physcion with regression coefficient r(2)>0.9995. The intra-day and inter-day precisions of this method were evaluated with the R.S.D. values less than 0.7% and 1.3%, respectively. The recoveries of the eight investigated compounds were ranged from 99.3% to 100.2% with R.S.D. values less than 1.5%. This method was successfully used to determine the 8 target compounds in 10 batches of Danning tablet.

  13. Comparison of UHPLC and HPLC in benzodiazepines analysis of postmortem samples: a case-control study.

    PubMed

    Behnoush, Behnam; Sheikhazadi, Ardeshir; Bazmi, Elham; Fattahi, Akbar; Sheikhazadi, Elham; Saberi Anary, Seyed Hossein

    2015-04-01

    The aim of this study was to compare system efficiency and analysis duration regarding the solvent consumption and system maintenance in high-pressure liquid chromatography (HPLC) and ultra high-pressure liquid chromatography (UHPLC). In a case-control study, standard solutions of 7 benzodiazepines (BZs) and 73 biological samples such as urine, tissue, stomach content, and bile that screened positive for BZs were analyzed by HPLC and UHPLC in laboratory of forensic toxicology during 2012 to 2013. HPLC analysis was performed using a Knauer by 100-5 C-18 column (250 mm × 4.6 mm) and Knauer photodiode array detector (PAD). UHPLC analysis was performed using Knauer PAD detector with cooling autosampler and Eurospher II 100-3 C-18 column (100 mm × 3 mm) and also 2 pumps. The mean retention time, standard deviation, flow rate, and repeatability of analytical results were compared by using 2 methods. Routine runtimes in HPLC and UHPLC took 40 and 15 minutes, respectively. Changes in mobile phase composition of the 2 methods were not required. Flow rate and solvent consumption in UHPLC decreased. Diazepam and flurazepam were detected more frequently in biological samples. In UHPLC, small particle size and short length of column cause effective separation of BZs in a very short time. Reduced flow rate, solvent consumption, and injection volume cause more efficiency and less analysis costs. Thus, in the detection of BZs, UHPLC is an accurate, sensitive, and fast method with less cost of analysis.

  14. Comparison of UHPLC and HPLC in Benzodiazepines Analysis of Postmortem Samples

    PubMed Central

    Behnoush, Behnam; Sheikhazadi, Ardeshir; Bazmi, Elham; Fattahi, Akbar; Sheikhazadi, Elham; Saberi Anary, Seyed Hossein

    2015-01-01

    Abstract The aim of this study was to compare system efficiency and analysis duration regarding the solvent consumption and system maintenance in high-pressure liquid chromatography (HPLC) and ultra high-pressure liquid chromatography (UHPLC). In a case–control study, standard solutions of 7 benzodiazepines (BZs) and 73 biological samples such as urine, tissue, stomach content, and bile that screened positive for BZs were analyzed by HPLC and UHPLC in laboratory of forensic toxicology during 2012 to 2013. HPLC analysis was performed using a Knauer by 100-5 C-18 column (250 mm × 4.6 mm) and Knauer photodiode array detector (PAD). UHPLC analysis was performed using Knauer PAD detector with cooling autosampler and Eurospher II 100-3 C-18 column (100 mm × 3 mm) and also 2 pumps. The mean retention time, standard deviation, flow rate, and repeatability of analytical results were compared by using 2 methods. Routine runtimes in HPLC and UHPLC took 40 and 15 minutes, respectively. Changes in mobile phase composition of the 2 methods were not required. Flow rate and solvent consumption in UHPLC decreased. Diazepam and flurazepam were detected more frequently in biological samples. In UHPLC, small particle size and short length of column cause effective separation of BZs in a very short time. Reduced flow rate, solvent consumption, and injection volume cause more efficiency and less analysis costs. Thus, in the detection of BZs, UHPLC is an accurate, sensitive, and fast method with less cost of analysis. PMID:25860209

  15. High perfomance liquid chromatography fingerprint analysis for quality control of brotowali (Tinospora crispa)

    NASA Astrophysics Data System (ADS)

    Syarifah, V. B.; Rafi, M.; Wahyuni, W. T.

    2017-05-01

    Brotowali (Tinospora crispa) is widely used in Indonesia as ingredient of herbal medicine formulation. To ensure the quality, safety, and efficacy of herbal medicine products, its chemical constituents should be continuously evaluated. High performance liquid chromatography (HPLC) fingerprint is one of powerful technique for this quality control process. In this study, HPLC fingerprint analysis method was developed for quality control of brotowali. HPLC analysis was performed in C18 column and detection was performed using photodiode array detector. The optimum mobile phase for brotowali fingerprint was acetonitrile (ACN) and 0.1% formic acid in gradient elution mode at a flow rate of 1 mL/min. The number of peaks detected in HPLC fingerprint of brotowali was 32 peaks and 23 peaks for stems and leaves, respectively. Berberine as marker compound was detected at retention time of 20.525 minutes. Evaluation of analytical performance including precision, reproducibility, and stability prove that this HPLC fingerprint analysis was reliable and could be applied for quality control of brotowali.

  16. Comprehensive two-dimensional chromatography with coupling of reversed phase high performance liquid chromatography and supercritical fluid chromatography.

    PubMed

    Stevenson, Paul G; Tarafder, Abhijit; Guiochon, Georges

    2012-01-13

    A 2D comprehensive chromatographic separation of blackberry sage fragrant oil was performed by using HPLC in the first dimension and SFC in the second. A C(18)-bonded silica column eluted with an ACN gradient was used in the HPLC dimension and an amino-bonded silica column eluted with ACN as a modifier in the SFC dimension. This 2D separation was completed in the off-line mode, the fractions from the HPLC column being collected and injected in the SFC column. The retention factors on the two columns have a -0.757 correlation coefficient. The method provides a practical peak capacity of 2400 in 280 min. The first eluted peaks in HPLC are the last ones eluted in SFC and vice versa. The results demonstrate that the coupling of an HPLC and an SFC separation have a great potential for 2D chromatographic separations. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Quality evaluation and pattern recognition analyses of marker compounds from five medicinal drugs of Rutaceae family by HPLC/PDA.

    PubMed

    Zhao, Bing Tian; Kim, Eun Jung; Son, Kun Ho; Son, Jong Keun; Min, Byung Sun; Woo, Mi Hee

    2015-08-01

    To establish a standard of quality control and to identify different origins for the Rutaceae family [Citri Unshiu Peel (CU), Citri Unshiu Immature Peel (CI), Ponciri Immature Fructus (PI), Aurantii Immature Fructus (AI), and Aurantii Fructus (AU)], 13 standards including rutin (1), narirutin (2), naringin (3), hesperidin (4), neohesperidin (5), neoponcirin (6), poncirin (7), naringenin (8), isosinensetin (9), sinensetin (10), nobiletin (11), heptamethoxyflavone (12), and tangeretin (13) were determined by high performance liquid chromatography (HPLC)/photo-diode array (PDA) analysis. A YMC ODS C18 (250 × 4.6 mm, 5 µm) column was used and the ratio of mobile phases of water (A) and acetonitrile (B) delivered to the column for gradient elution was applied. This method was fully validated with respect to linearity, accuracy, precision, stability, and robustness. The HPLC/PDA method was applied successfully to quantify 13 major compounds in the extracts of CU, CI, PI, AI, and AU. The pattern recognition analysis combined with LC chromatographic data was performed by repeated analysis of 27 reference samples in the above five Rutaceae oriental medicinal drugs. The established HPLC method was rapid and reliable for quantitative analysis and quality control of multiple components in five Rutaceae species with different origins.

  18. Quality Evaluation and Chemical Markers Screening of Salvia miltiorrhiza Bge. (Danshen) Based on HPLC Fingerprints and HPLC-MSn Coupled with Chemometrics.

    PubMed

    Liang, Wenyi; Chen, Wenjing; Wu, Lingfang; Li, Shi; Qi, Qi; Cui, Yaping; Liang, Linjin; Ye, Ting; Zhang, Lanzhen

    2017-03-17

    Danshen, the dried root of Salvia miltiorrhiza Bge., is a widely used commercially available herbal drug, and unstable quality of different samples is a current issue. This study focused on a comprehensive and systematic method combining fingerprints and chemical identification with chemometrics for discrimination and quality assessment of Danshen samples. Twenty-five samples were analyzed by HPLC-PAD and HPLC-MS n . Forty-nine components were identified and characteristic fragmentation regularities were summarized for further interpretation of bioactive components. Chemometric analysis was employed to differentiate samples and clarify the quality differences of Danshen including hierarchical cluster analysis, principal component analysis, and partial least squares discriminant analysis. Consistent results were that the samples were divided into three categories which reflected the difference in quality of Danshen samples. By analyzing the reasons for sample classification, it was revealed that the processing method had a more obvious impact on sample classification than the geographical origin, it induced the different content of bioactive compounds and finally lead to different qualities. Cryptotanshinone, trijuganone B, and 15,16-dihydrotanshinone I were screened out as markers to distinguish samples by different processing methods. The developed strategy could provide a reference for evaluation and discrimination of other traditional herbal medicines.

  19. High performance liquid chromatography used for quality control of Achyranthis Radix.

    PubMed

    Zhao, Bing Tian; Jeong, Su Yang; Moon, Dong Cheul; Son, Kun Ho; Son, Jong Keun; Woo, Mi Hee

    2012-08-01

    To establish a standard of quality control and to identify reliable Achyranthis Radix, three phytoecdysones including ecdysterone (1), 25R-inokosterone (2) and 25S-inokosterone (3) were determined by quantitative HPLC/UV analysis. Three phytoecdysones were separated with an YMC J'sphere ODS C(18) column (250 mm × 4.6 mm, 4 μm) by isocratic elution using 0.1% formic acid in water and acetonitrile (85:15, v/v%) as the mobile phase. The flow rate was 1.0 mL/min and the UV detector wavelength was set at 245 nm. The standards were quantified by HPLC/UV from Achyranthes bidentata Blume and Achyranthes japonica Nakai, as well as Cyathula capitata Moq. and Cyathula officinalis Kuan, which are of a different genus but are comparative herbs. The method was successfully used in the analysis of Achyranthis Radix of different geographical origin or genera with relatively simple conditions and procedures, and the assay results were satisfactory for linearity, recovery, precision, accuracy, stability and robustness. The HPLC analytical method for pattern recognition analysis was validated by repeated analysis of eighteen A. bidentata Blume samples and ten A. japonica Nakai samples. The results indicate that the established HPLC/UV method is suitable for quantitation and pattern recognition analyses for quality evaluation of Achyranthis Radix.

  20. Development and validation of an HPLC method for simultaneous determination of trimethoprim and sulfamethoxazole in human plasma.

    PubMed

    Sayar, Esin; Sahin, Selma; Cevheroglu, Semsettin; Hincal, A Atilla

    2010-09-01

    The combination of trimethoprim (TMP) and sulfamethoxazole (SMX) is used in the treatment of many common infections such as urinary, respiratory and gastrointestinal tract infections. The aim of this study was to determine TMP and SMX simultaneously in human plasma samples by high performance liquid chromatography (HPLC) using antipyrine as the internal standard. Separation of the compounds was achieved on a reverse-phase C8 column packed with 5 microm dimethyl octadecylsilyl bonded amorphous silica (4.6 mm x 250 mm) column using a mobile phase consisted of potassium hydrogen phosphate, acetonitrile, methanol and water adjusted to pH 6.2. The mobile phase was delivered at a flow rate of 1 mL min- and the effluent was monitored using Max plot technique at 25 derees C. Retention times were 5 min for TMP, 7 min for antipyrine and 9 min for SMX. Quantitation limits were 10 ng mL(-1) for TMP and 50 ng mL(-1) for SMX. Our findings indicated that the developed HPLC method was precise, accurate, specific and sensitive for simultaneous determination of TMP and SMX. Proposed HPLC method was successfully applied for the analysis of TMP and SMX in human plasma after oral administration of a co-trimoxazole tablet to human volunteers.

Top