D0 Solenoid Upgrade Project: Vacuum Pumping Calculations for the D0 Solenoid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rucinski, R.; /Fermilab
1993-08-02
This engineering note documents the calculations done to determine the vacuum pumping speed for the D-Zero solenoid. The raw calculations are attached. A summary of the results are listed. The vacuum pumping speed of the solenoid is determined by the conductance of the pumping path. At higher pressure ranges during initial pumpdown, the conductances will be rather high. Calculations were not done for the transient pumpdown period, only the steady state type pumping situation. The pressure is assumed to be on the order of 10E-7 torr. This is the free molecular flow regime based on Knudsen number. This pressure regimemore » is also where the pumping speed would be least. The conductances were calculated based on pumping helium gas at a temperature of 300 Kelvin. The total conductance of the pumping path from the solenoid to the inlet of the turbomolecular pump is 11.8 L/s. The effective pumping speed of a 1000 L/s turbo pump attached to this pumping path is 11.7 L/s. The minimum required pumping speed for design purposes was set at 4.3 L/s. This value was arrived at by assuming a warm leak size (10E-8 atm-cc/sec) was not detected during fabrication of the solenoid. It is then assumed that the leak leaks cold liquid helium into the vacuum space. With this leak rate, a 4.3 L/s pumping speed would be able to maintain a 2 x 10E-7 torr pressure in the solenoid vacuum jacket. The solenoid would be able to be operated with this small leak with continuous pumping.« less
NASA Astrophysics Data System (ADS)
Chen, Jing; Qiu, Xiaojie; Yin, Cunyi; Jiang, Hao
2018-02-01
An efficient method to design the broadband gain-flattened Raman fiber amplifier with multiple pumps is proposed based on least squares support vector regression (LS-SVR). A multi-input multi-output LS-SVR model is introduced to replace the complicated solving process of the nonlinear coupled Raman amplification equation. The proposed approach contains two stages: offline training stage and online optimization stage. During the offline stage, the LS-SVR model is trained. Owing to the good generalization capability of LS-SVR, the net gain spectrum can be directly and accurately obtained when inputting any combination of the pump wavelength and power to the well-trained model. During the online stage, we incorporate the LS-SVR model into the particle swarm optimization algorithm to find the optimal pump configuration. The design results demonstrate that the proposed method greatly shortens the computation time and enhances the efficiency of the pump parameter optimization for Raman fiber amplifier design.
2006-03-17
perpendicularly. Each source chamber is pumped by a 2000 ls-1 and a 430 ls-1 maglev pump (Osaka Vacuum; TG2003 and TG430) to the low 10-8 torr region...the operation of pulsed and continuous sources increases the pressure to about 10-5 torr and 10-4 torr, respectively. All maglev pumps require no
EP of a Different Class: The Challenges of Testing for MW Missions
2012-07-20
that the pumping capacity of the Large Vacuum Test Facility (LVTF) at PEPL (Figure 3) at 520,000 l/s on air makes it most suitable for initial checkout...evaluation of the thruster. NASA Glenn Research Center’s Vacuum Facility 5 (VF5) (Figure 4), with its increased pumping speed of 3,500,000 l/s on air...reader to Dr. Dan Goebel’s IEPC 2011 paper.41 IV. Facility Selection and Preparation Facility Size and Pumping High T/P thruster testing
On NUFFT-based gridding for non-Cartesian MRI
NASA Astrophysics Data System (ADS)
Fessler, Jeffrey A.
2007-10-01
For MRI with non-Cartesian sampling, the conventional approach to reconstructing images is to use the gridding method with a Kaiser-Bessel (KB) interpolation kernel. Recently, Sha et al. [L. Sha, H. Guo, A.W. Song, An improved gridding method for spiral MRI using nonuniform fast Fourier transform, J. Magn. Reson. 162(2) (2003) 250-258] proposed an alternative method based on a nonuniform FFT (NUFFT) with least-squares (LS) design of the interpolation coefficients. They described this LS_NUFFT method as shift variant and reported that it yielded smaller reconstruction approximation errors than the conventional shift-invariant KB approach. This paper analyzes the LS_NUFFT approach in detail. We show that when one accounts for a certain linear phase factor, the core of the LS_NUFFT interpolator is in fact real and shift invariant. Furthermore, we find that the KB approach yields smaller errors than the original LS_NUFFT approach. We show that optimizing certain scaling factors can lead to a somewhat improved LS_NUFFT approach, but the high computation cost seems to outweigh the modest reduction in reconstruction error. We conclude that the standard KB approach, with appropriate parameters as described in the literature, remains the practical method of choice for gridding reconstruction in MRI.
Signal-Preserving Erratic Noise Attenuation via Iterative Robust Sparsity-Promoting Filter
Zhao, Qiang; Du, Qizhen; Gong, Xufei; ...
2018-04-06
Sparse domain thresholding filters operating in a sparse domain are highly effective in removing Gaussian random noise under Gaussian distribution assumption. Erratic noise, which designates non-Gaussian noise that consists of large isolated events with known or unknown distribution, also needs to be explicitly taken into account. However, conventional sparse domain thresholding filters based on the least-squares (LS) criterion are severely sensitive to data with high-amplitude and non-Gaussian noise, i.e., the erratic noise, which makes the suppression of this type of noise extremely challenging. Here, in this paper, we present a robust sparsity-promoting denoising model, in which the LS criterion ismore » replaced by the Huber criterion to weaken the effects of erratic noise. The random and erratic noise is distinguished by using a data-adaptive parameter in the presented method, where random noise is described by mean square, while the erratic noise is downweighted through a damped weight. Different from conventional sparse domain thresholding filters, definition of the misfit between noisy data and recovered signal via the Huber criterion results in a nonlinear optimization problem. With the help of theoretical pseudoseismic data, an iterative robust sparsity-promoting filter is proposed to transform the nonlinear optimization problem into a linear LS problem through an iterative procedure. The main advantage of this transformation is that the nonlinear denoising filter can be solved by conventional LS solvers. Lastly, tests with several data sets demonstrate that the proposed denoising filter can successfully attenuate the erratic noise without damaging useful signal when compared with conventional denoising approaches based on the LS criterion.« less
Signal-Preserving Erratic Noise Attenuation via Iterative Robust Sparsity-Promoting Filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Qiang; Du, Qizhen; Gong, Xufei
Sparse domain thresholding filters operating in a sparse domain are highly effective in removing Gaussian random noise under Gaussian distribution assumption. Erratic noise, which designates non-Gaussian noise that consists of large isolated events with known or unknown distribution, also needs to be explicitly taken into account. However, conventional sparse domain thresholding filters based on the least-squares (LS) criterion are severely sensitive to data with high-amplitude and non-Gaussian noise, i.e., the erratic noise, which makes the suppression of this type of noise extremely challenging. Here, in this paper, we present a robust sparsity-promoting denoising model, in which the LS criterion ismore » replaced by the Huber criterion to weaken the effects of erratic noise. The random and erratic noise is distinguished by using a data-adaptive parameter in the presented method, where random noise is described by mean square, while the erratic noise is downweighted through a damped weight. Different from conventional sparse domain thresholding filters, definition of the misfit between noisy data and recovered signal via the Huber criterion results in a nonlinear optimization problem. With the help of theoretical pseudoseismic data, an iterative robust sparsity-promoting filter is proposed to transform the nonlinear optimization problem into a linear LS problem through an iterative procedure. The main advantage of this transformation is that the nonlinear denoising filter can be solved by conventional LS solvers. Lastly, tests with several data sets demonstrate that the proposed denoising filter can successfully attenuate the erratic noise without damaging useful signal when compared with conventional denoising approaches based on the LS criterion.« less
Design of a large magnetic-bearing turbomolecular pump for NET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernhardt, K.H.; Conrad, A.; Dinner, P.J.
1988-09-01
The feasibility of development of large vacuum components for operation in fusion machines have been investigated in the framework of the European Fusion Technology Programme. The requirements and the results of the feasibility study for the large turbomolecular pump units (TMP) are presented. Design parameters for single flow 50.000 l/s TMP and a double flow 15.000 and a 50.000 l/s TMP have been compared.
High-Capacity, Portable Firefighting Pump
NASA Technical Reports Server (NTRS)
Burns, Ralph A.
1988-01-01
Report describes an evaluation of firefighting module that delivers water at 5,000 gal/min (320 L/s). Is compact, self-contained, portable water pump. Besides firefighting, module used for flood control, pumping water into large vessels, and pump water from sinking ships.
Channel estimation based on quantized MMP for FDD massive MIMO downlink
NASA Astrophysics Data System (ADS)
Guo, Yao-ting; Wang, Bing-he; Qu, Yi; Cai, Hua-jie
2016-10-01
In this paper, we consider channel estimation for Massive MIMO systems operating in frequency division duplexing mode. By exploiting the sparsity of propagation paths in Massive MIMO channel, we develop a compressed sensing(CS) based channel estimator which can reduce the pilot overhead. As compared with the conventional least squares (LS) and linear minimum mean square error(LMMSE) estimation, the proposed algorithm is based on the quantized multipath matching pursuit - MMP - reduced the pilot overhead and performs better than other CS algorithms. The simulation results demonstrate the advantage of the proposed algorithm over various existing methods including the LS, LMMSE, CoSaMP and conventional MMP estimators.
A modified JPEG-LS lossless compression method for remote sensing images
NASA Astrophysics Data System (ADS)
Deng, Lihua; Huang, Zhenghua
2015-12-01
As many variable length source coders, JPEG-LS is highly vulnerable to channel errors which occur in the transmission of remote sensing images. The error diffusion is one of the important factors which infect its robustness. The common method of improving the error resilience of JPEG-LS is dividing the image into many strips or blocks, and then coding each of them independently, but this method reduces the coding efficiency. In this paper, a block based JPEP-LS lossless compression method with an adaptive parameter is proposed. In the modified scheme, the threshold parameter RESET is adapted to an image and the compression efficiency is close to that of the conventional JPEG-LS.
NASA Astrophysics Data System (ADS)
Wu, Peilin; Zhang, Qunying; Fei, Chunjiao; Fang, Guangyou
2017-04-01
Aeromagnetic gradients are typically measured by optically pumped magnetometers mounted on an aircraft. Any aircraft, particularly helicopters, produces significant levels of magnetic interference. Therefore, aeromagnetic compensation is essential, and least square (LS) is the conventional method used for reducing interference levels. However, the LSs approach to solving the aeromagnetic interference model has a few difficulties, one of which is in handling multicollinearity. Therefore, we propose an aeromagnetic gradient compensation method, specifically targeted for helicopter use but applicable on any airborne platform, which is based on the ɛ-support vector regression algorithm. The structural risk minimization criterion intrinsic to the method avoids multicollinearity altogether. Local aeromagnetic anomalies can be retained, and platform-generated fields are suppressed simultaneously by constructing an appropriate loss function and kernel function. The method was tested using an unmanned helicopter and obtained improvement ratios of 12.7 and 3.5 in the vertical and horizontal gradient data, respectively. Both of these values are probably better than those that would have been obtained from the conventional method applied to the same data, had it been possible to do so in a suitable comparative context. The validity of the proposed method is demonstrated by the experimental result.
Shah, Parag K; Narendran, V; Kalpana, N
2011-01-01
To compare structural and functional outcome and time efficiency between standard spot sized conventional pulsed mode diode laser and continuous mode large spot transpupillary thermotherapy (LS TTT) for treatment of high risk prethreshold retinopathy of prematurity (ROP). Ten eyes of five preterm babies having bilateral symmetrical high risk prethreshold ROP were included in this study. One eye of each baby was randomized to get either standard spot sized conventional pulsed mode diode laser or continuous mode LS TTT. There was no significant difference between structural or functional outcome in either group. The mean time taken for conventional diode laser was 20.07 minutes, while that for LS TTT was 12.3 minutes. LS TTT was 40% more time efficient than the conventional laser. It may be better suited for the very small fragile premature infants as it is quicker than the conventional laser.
Environmental Effects on Fatigue Crack Growth in High Performance Aluminum Alloys
2009-03-13
tested for leaks to a rate of 2x 10 cm3/s with helium. All devices connected to the chamber, including pumps , gages and valves, are ultra-high- vacuum ...Pfeiffer TMU-262P), backed by a 5 L/s scroll pump (ULVAC DIS-250). This pump combination eliminates the possibility of contamination by pumping fluid used...both pumps are connected directly to the vacuum chamber to achieve optimum pump -down speeds. Pumping down the chamber is further facilitated by use of
Three Dimensional Imaging of Helicon Wave Fields Via Magnetic Induction Probes
2009-07-13
Elastomer Flange 50 The chamber is pumped by a Varian TV-300 HT turbomolecular vacuum pump with a pumping speed of 250 l/s backed by a dry scroll ... vacuum diffusion chamber with pump locations .................................................. 49 Figure 3.2. RF power delivery system...steel, 0.5 meter diameter by 1.0 meter long vacuum chamber. It has 24 access ports / flanges of varying diameter for diagnostic feed-throughs, pumping
Li, Yankun; Shao, Xueguang; Cai, Wensheng
2007-04-15
Consensus modeling of combining the results of multiple independent models to produce a single prediction avoids the instability of single model. Based on the principle of consensus modeling, a consensus least squares support vector regression (LS-SVR) method for calibrating the near-infrared (NIR) spectra was proposed. In the proposed approach, NIR spectra of plant samples were firstly preprocessed using discrete wavelet transform (DWT) for filtering the spectral background and noise, then, consensus LS-SVR technique was used for building the calibration model. With an optimization of the parameters involved in the modeling, a satisfied model was achieved for predicting the content of reducing sugar in plant samples. The predicted results show that consensus LS-SVR model is more robust and reliable than the conventional partial least squares (PLS) and LS-SVR methods.
A study of water pump efficiency for household water demand at Lubuklinggau
NASA Astrophysics Data System (ADS)
Emiliawati, Anna
2017-11-01
Water pump is a device to transport liquid from one place to another. This device is used in most of household in Indonesia. Small-scale water pump which is effective to lift more discharge is generally used. The ones that are most preferred are centrifugal types which having low absorbability. Pump performance is limited by pressure level in real electrical power whereas pump efficiency is influenced by head and discharge. The research aims to find out the efficiency of five distinct brands of home water pumps which are broadly distributed in market. Efficiency analysis take by laboratorium and financial analysis using NPV and BCR are done in order to obtained dicharge and pressure from each pump. At the end of the research, one out of 5 home water pump brands will be selected as the optimal working home water pump with low operational expense based on the utilizing age. The result of the research shows that the maximum efficiency value among various brands of water pump is diverse. Each value is arranged as follow from water pump A to E orderly: 12,9%, 13,5%, 12,8%, 14,8%, and 3,4%. From the calculation, water demand of South Lubuklinggau at stage 1 is 1117,7 l/s and stage 2 is 3495,2 l/s.. Moreover, the researcher conducts of investment, operation and maintenance cost with 25 years pump utilizing age towards 2 conditions (1) of maximum efficiency, i.e. pump A Rp16.563.971; pump B Rp12.163.798; pump C Rp11.809.513,2; pump D Rp11.473.928,3; pump E Rp12.648.708,3; (2) of max discharge, i.e. pump A Rp111.993.822,8; pump B Rp26.128.845,1; pump C Rp51.697.208,8; pump D Rp51.098.687,4; pump E Rp22.915.952,7;Financial analysis with interest rate 13% show a positive NPV(+) for all pump except pump A in max efficiency and a negative NPV (-) for all except pump B in max discharge. BCR value for max efficiency are pump A 0,8; pump B 1,6; pump C 1,7; pump D 1,7 and pump E 1,3. And for max discharge are pump A 0,2; pump B 1,1; pump C 0,7; pump D 0,7 and pump E 0,9. Result from that analysis obtained pump B are feasible with low cost and high benefit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Xiaobing; Zheng, O'Neill; Niu, Fuxin
Most commercial ground source heat pump systems (GSHP) in the United States are in a distributed configuration. These systems circulate water or an anti-freeze solution through multiple heat pump units via a central pumping system, which usually uses variable speed pump(s). Variable speed pumps have potential to significantly reduce pumping energy use; however, the energy savings in reality could be far away from its potential due to improper pumping system design and controls. In this paper, a simplified hydronic pumping system was simulated with the dynamic Modelica models to evaluate three different pumping control strategies. This includes two conventional controlmore » strategies, which are to maintain a constant differential pressure across either the supply and return mains, or at the most hydraulically remote heat pump; and an innovative control strategy, which adjusts system flow rate based on the demand of each heat pump. The simulation results indicate that a significant overflow occurs at part load conditions when the variable speed pump is controlled to main a constant differential pressure across the supply and return mains of the piping system. On the other hand, an underflow occurs at part load conditions when the variable speed pump is controlled to maintain a constant differential pressure across the furthest heat pump. The flow-demand-based control can provide needed flow rate to each heat pump at any given time, and with less pumping energy use than the two conventional controls. Finally, a typical distributed GSHP system was studied to evaluate the energy saving potential of applying the flow-demand-based pumping control strategy. This case study shows that the annual pumping energy consumption can be reduced by 62% using the flow-demand-based control compared with that using the conventional pressure-based control to maintain a constant differential pressure a cross the supply and return mains.« less
Liu, Xiaobing; Zheng, O'Neill; Niu, Fuxin
2016-01-01
Most commercial ground source heat pump systems (GSHP) in the United States are in a distributed configuration. These systems circulate water or an anti-freeze solution through multiple heat pump units via a central pumping system, which usually uses variable speed pump(s). Variable speed pumps have potential to significantly reduce pumping energy use; however, the energy savings in reality could be far away from its potential due to improper pumping system design and controls. In this paper, a simplified hydronic pumping system was simulated with the dynamic Modelica models to evaluate three different pumping control strategies. This includes two conventional controlmore » strategies, which are to maintain a constant differential pressure across either the supply and return mains, or at the most hydraulically remote heat pump; and an innovative control strategy, which adjusts system flow rate based on the demand of each heat pump. The simulation results indicate that a significant overflow occurs at part load conditions when the variable speed pump is controlled to main a constant differential pressure across the supply and return mains of the piping system. On the other hand, an underflow occurs at part load conditions when the variable speed pump is controlled to maintain a constant differential pressure across the furthest heat pump. The flow-demand-based control can provide needed flow rate to each heat pump at any given time, and with less pumping energy use than the two conventional controls. Finally, a typical distributed GSHP system was studied to evaluate the energy saving potential of applying the flow-demand-based pumping control strategy. This case study shows that the annual pumping energy consumption can be reduced by 62% using the flow-demand-based control compared with that using the conventional pressure-based control to maintain a constant differential pressure a cross the supply and return mains.« less
Optimal rotated staggered-grid finite-difference schemes for elastic wave modeling in TTI media
NASA Astrophysics Data System (ADS)
Yang, Lei; Yan, Hongyong; Liu, Hong
2015-11-01
The rotated staggered-grid finite-difference (RSFD) is an effective approach for numerical modeling to study the wavefield characteristics in tilted transversely isotropic (TTI) media. But it surfaces from serious numerical dispersion, which directly affects the modeling accuracy. In this paper, we propose two different optimal RSFD schemes based on the sampling approximation (SA) method and the least-squares (LS) method respectively to overcome this problem. We first briefly introduce the RSFD theory, based on which we respectively derive the SA-based RSFD scheme and the LS-based RSFD scheme. Then different forms of analysis are used to compare the SA-based RSFD scheme and the LS-based RSFD scheme with the conventional RSFD scheme, which is based on the Taylor-series expansion (TE) method. The contrast in numerical accuracy analysis verifies the greater accuracy of the two proposed optimal schemes, and indicates that these schemes can effectively widen the wavenumber range with great accuracy compared with the TE-based RSFD scheme. Further comparisons between these two optimal schemes show that at small wavenumbers, the SA-based RSFD scheme performs better, while at large wavenumbers, the LS-based RSFD scheme leads to a smaller error. Finally, the modeling results demonstrate that for the same operator length, the SA-based RSFD scheme and the LS-based RSFD scheme can achieve greater accuracy than the TE-based RSFD scheme, while for the same accuracy, the optimal schemes can adopt shorter difference operators to save computing time.
Laser scanning saturated structured illumination microscopy based on phase modulation
NASA Astrophysics Data System (ADS)
Huang, Yujia; Zhu, Dazhao; Jin, Luhong; Kuang, Cuifang; Xu, Yingke; Liu, Xu
2017-08-01
Wide-field saturated structured illumination microscopy has not been widely used due to the requirement of high laser power. We propose a novel method called laser scanning saturated structured illumination microscopy (LS-SSIM), which introduces high order of harmonics frequency and greatly reduces the required laser power for SSIM imaging. To accomplish that, an excitation PSF with two peaks is generated and scanned along different directions on the sample. Raw images are recorded cumulatively by a CCD detector and then reconstructed to form a high-resolution image with extended optical transfer function (OTF). Our theoretical analysis and simulation results show that LS-SSIM method reaches a resolution of 0.16 λ, equivalent to 2.7-fold resolution than conventional wide-field microscopy. In addition, LS-SSIM greatly improves the optical sectioning capability of conventional wide-field illumination system by diminishing our-of-focus light. Furthermore, this modality has the advantage of implementation in multi-photon microscopy with point scanning excitation to image samples in greater depths.
Liu, Chuanyuan; Liu, Jungang; Zhang, Sen
2011-11-01
To systematically evaluate the immune function in patients with colorectal cancer after laparoscopic surgery (LS) and conventional open surgery (OS). PUBMED, EMBASE, and the Cochrane library were searched and randomized controlled trials (RCTs) comparing the immunological difference between LS and OS were included. Two authors extracted data and assessed trial quality. Eleven studies including 695 patients were analysed. Immune-competent cells demonstrated no significant differences between LS and OS in six trials. Eight trials assessed various perioperative plasma cytokine concentrations with no significant differences in interleukin-6 (IL-6) and C-reactive protein (CRP) levels between LS and OS. However, meta-analysis showed higher T suppressor lymphocytes (CD8+) counts on postoperative days (POD) 1-3 and lower plasma levels of CRP on POD 0-1 in LS group compared with OS group. Although LS groups displayed higher T suppressor lymphocyte (CD8+) counts on postoperative days (POD) 1-3 and lower plasma levels of CRP on POD 0-1, there is no sufficient evidence to support superior preservation of global immune function with LS compared to OS.
NASA Astrophysics Data System (ADS)
Wu, Di; He, Yong
2007-11-01
The aim of this study is to investigate the potential of the visible and near infrared spectroscopy (Vis/NIRS) technique for non-destructive measurement of soluble solids contents (SSC) in grape juice beverage. 380 samples were studied in this paper. Smoothing way of Savitzky-Golay and standard normal variate were applied for the pre-processing of spectral data. Least-squares support vector machines (LS-SVM) with RBF kernel function was applied to developing the SSC prediction model based on the Vis/NIRS absorbance data. The determination coefficient for prediction (Rp2) of the results predicted by LS-SVM model was 0. 962 and root mean square error (RMSEP) was 0. 434137. It is concluded that Vis/NIRS technique can quantify the SSC of grape juice beverage fast and non-destructively.. At the same time, LS-SVM model was compared with PLS and back propagation neural network (BP-NN) methods. The results showed that LS-SVM was superior to the conventional linear and non-linear methods in predicting SSC of grape juice beverage. In this study, the generation ability of LS-SVM, PLS and BP-NN models were also investigated. It is concluded that LS-SVM regression method is a promising technique for chemometrics in quantitative prediction.
Self-regenerating Nanotips: Indestructable Field-emission Cathodes for Low-power Electric Propulsion
2010-09-27
Field Emission Scanning Electron Microscope. The chamber was evacuated using a series of three ion pumps and vacuum pressure of 10-7 Torr was...backed by a 110-L/min dry scroll pump . The chamber is also equipped with a 300-L/s combination ion/sublimation pump that can maintain pressure of...Torr for 2 to 24 hours and then the ion pump was turned off to let the vacuum pressure slowly increase while observing the electron emission
A review of the use of Al-alloy vacuum components for operation at 10-13 Torr
NASA Astrophysics Data System (ADS)
Ishimaru, Hajime
1990-02-01
An extremely high vacuum (XHV) chamber was fabricated and tested. The vacuum chamber was made of special surface finished (EX-process) aluminum alloy in oxygen and argon atmosphere. The chamber was assembled using TIG welding in an argon atmosphere and by electron beam welding. The system was evacuated with a turbo-backed 300 l/s turbomolecular pump separated from the main chamber using a right angle valve. The liquid nitrogen shroud is installed inside the main vacuum chamber. The XHV is maintained by two 300 l/s sputter ion pumps and a titanium sublimation pump with a liquid nitrogen shroud. These pumps are also made of aluminum alloys. An ultimate pressure of 3×10-13 Torr was measured with a point collector gauge with a spherical anode mounted on an Al-flange. Residual gas analysis in the order 10-13 Torr was performed by a newly developed Q-mass filter. To suppress outgassing from the quadrupole electrode, the ion source is mounted on an Al-flange separated from the quadrupole electrode.
Laparoscopic splenectomy using conventional instruments
Dalvi, A. N.; Thapar, P. M.; Deshpande, A. A.; Rege, S. A.; Prabhu, R. Y.; Supe, A. N.; Kamble, R. S.
2005-01-01
Introduction: Laparoscopic splenectomy (LS) is an accepted procedure for elective splenectomy. Advancement in technology has extended the possibility of LS in massive splenomegaly [Choy et al., J Laparoendosc Adv Surg Tech A 14(4), 197–200 (2004)], trauma [Ren et al., Surg Endosc 15(3), 324 (2001); Mostafa et al., Surg Laparosc Endosc Percutan Tech 12(4), 283–286 (2002)], and cirrhosis with portal hypertension [Hashizume et al., Hepatogastroenterology 49(45), 847–852 (2002)]. In a developing country, these advanced gadgets may not be always available. We performed LS using conventional and reusable instruments in a public teaching the hospital without the use of the advanced technology. The technique of LS and the outcome in these patients is reported. Materials and Methods: Patients undergoing LS for various hematological disorders from 1998 to 2004 were included. Electrocoagulation, clips, and intracorporeal knotting were the techniques used for tackling short-gastric vessels and splenic pedicle. Specimen was delivered through a Pfannensteil incision. Results: A total of 26 patients underwent LS. Twenty-two (85%) of patients had spleen size more than 500 g (average weight being 942.55 g). Mean operative time was 214 min (45–390 min). The conversion rate was 11.5% (n = 3). Average duration of stay was 5.65 days (3–30 days). Accessory spleen was detected and successfully removed in two patients. One patient developed subphrenic abscess. There was no mortality. There was no recurrence of hematological disease. Conclusion: Laparoscopic splenectomy using conventional equipment and instruments is safe and effective. Advanced technology has a definite advantage but is not a deterrent to the practice of LS. PMID:21206648
Making the Constitution Meaningful.
ERIC Educational Resources Information Center
Pelow, Randall A.
1989-01-01
Describes learning activities based on the U.S. Constitution that enhance higher level thinking skills in elementary students. One activity proposes a hypothetical constitutional amendment banning Saturday cartoons; a second taxes children's earnings; and other activities focus on dramatizing events surrounding the Constitutional Convention. (LS)
The effect of a source-contacted light shield on the electrical characteristics of an LTPS TFT
NASA Astrophysics Data System (ADS)
Kim, Miryeon; Sun, Wookyung; Kang, Jongseuk; Shin, Hyungsoon
2017-08-01
The electrical characteristics of a low-temperature polycrystalline silicon thin-film transistor (TFT) with a source-contacted light shield (SCLS) are observed and analyzed. Compared with that of a conventional TFT without a light shield (LS), the on-current of the TFT with an SCLS is lower because the SCLS blocks the fringing electric field from the drain to the active layer. Furthermore, the gate-to-source capacitance (C gs) of the TFT with an SCLS in the off and saturation regions is higher than that of a conventional TFT, which is due to the gate-to-LS capacitance (C g-LS). The electrical characteristics of the TFT with an SCLS are thoroughly investigated by two-dimensional device simulations, and a semi-empirical C g-LS model for SPICE simulation is proposed and verified.
Gastrostomy feeding tube - pump - child
... at home. In: O'Keefe SJD, ed. The Principles and Practice of Nutritional Support . New York, NY: Springer; 2015:chap 10. Schattner MA, Grossman EB. Nutritional management. In: Feldman M, Friedman LS, Brandt LJ, eds. ...
Paper pump for passive and programmable transport
Wang, Xiao; Hagen, Joshua A.; Papautsky, Ian
2013-01-01
In microfluidic systems, a pump for fluid-driving is often necessary. To keep the size of microfluidic systems small, a pump that is small in size, light-weight and needs no external power source is advantageous. In this work, we present a passive, simple, ultra-low-cost, and easily controlled pumping method based on capillary action of paper that pumps fluid through conventional polymer-based microfluidic channels with steady flow rate. By using inexpensive cutting tools, paper can be shaped and placed at the outlet port of a conventional microfluidic channel, providing a wide range of pumping rates. A theoretical model was developed to describe the pumping mechanism and aid in the design of paper pumps. As we show, paper pumps can provide steady flow rates from 0.3 μl/s to 1.7 μl/s and can be cascaded to achieve programmable flow-rate tuning during the pumping process. We also successfully demonstrate transport of the most common biofluids (urine, serum, and blood). With these capabilities, the paper pump has the potential to become a powerful fluid-driving approach that will benefit the fielding of microfluidic systems for point-of-care applications. PMID:24403999
Development of a Compact, Efficient Cooling Pump for Space Suit Life Support Systems
NASA Technical Reports Server (NTRS)
van Boeyen, Roger; Reeh, Jonathan; Trevino, Luis
2009-01-01
A compact, low-power electrochemically-driven fluid cooling pump is currently being developed by Lynntech, Inc. With no electric motor and minimal lightweight components, the pump is significantly lighter than conventional rotodynamic and displacement pumps. Reliability and robustness is achieved with the absence of rotating or moving components (apart from the bellows). By employing sulfonated polystyrene-based proton exchange membranes, rather than conventional Nafion membranes, a significant reduction in the actuator power consumption was demonstrated. Lynntech also demonstrated that these membranes possess the necessary mechanical strength, durability, and temperature range for long life space operation. The preliminary design for a Phase II prototype pump compares very favorably to the fluid cooling pumps currently used in space suit primary life support systems (PLSSs). Characteristics of the electrochemically-driven pump are described and the benefits of the technology as a replacement for electric motor pumps in mechanically pumped single-phase fluid loops is discussed.
Discrimination of transgenic soybean seeds by terahertz spectroscopy
NASA Astrophysics Data System (ADS)
Liu, Wei; Liu, Changhong; Chen, Feng; Yang, Jianbo; Zheng, Lei
2016-10-01
Discrimination of genetically modified organisms is increasingly demanded by legislation and consumers worldwide. The feasibility of a non-destructive discrimination of glyphosate-resistant and conventional soybean seeds and their hybrid descendants was examined by terahertz time-domain spectroscopy system combined with chemometrics. Principal component analysis (PCA), least squares-support vector machines (LS-SVM) and PCA-back propagation neural network (PCA-BPNN) models with the first and second derivative and standard normal variate (SNV) transformation pre-treatments were applied to classify soybean seeds based on genotype. Results demonstrated clear differences among glyphosate-resistant, hybrid descendants and conventional non-transformed soybean seeds could easily be visualized with an excellent classification (accuracy was 88.33% in validation set) using the LS-SVM and the spectra with SNV pre-treatment. The results indicated that THz spectroscopy techniques together with chemometrics would be a promising technique to distinguish transgenic soybean seeds from non-transformed seeds with high efficiency and without any major sample preparation.
Ultrafast High Harmonic, Soft X-Ray Probing of Molecular Dynamics
2013-04-30
590 L/s scroll pump and a titanium sublimation pump . A TOF-PES has been designed and constructed to analyze the energy of the photoelectrons...are studied using the quasi-continuous vacuum ultraviolet light of the Advanced Light Source at Lawrence Berkeley National Laboratory. The molecular...34), the method of high order harmonic generation of ultrashort vacuum ultraviolet pulses was used to investigate molecular photodissociation, ultrafast
New Large Diameter RF Complex Plasma Device
NASA Astrophysics Data System (ADS)
Meyer, John; Nosenko, Volodymyr; Thomas, Hubertus
2016-10-01
The Complex Plasma Research Group at the German Aerospace Center (DLR) in Oberpfaffenhofen has built a new large diameter rf plasma setup for dusty plasma experiments. The vacuum chamber is a stainless steel cylinder 0.90 m in diameter and 0.34 m in height with ports for viewing and measurement. A 0.85 m diameter plate in about the center serves as a powered electrode (13.56 MHz) with the chamber walls as the ground. It is pumped on by one of two Oerlikon turbo pumps with a pumping rate of 1100 l/s or 270 l/s. Argon gas is admitted into the chamber by an MKS mass flow meter and pumping is regulated by a butterfly valve to set pressure for experiments. A manual dropper is used to insert dust into the plasma. The dust is illuminated horizontally by a 660 nm 100 mW laser sheet and viewed from above by a Photron FASTCAM 1024 PCI camera. A vertical laser sheet of 635 nm will be used for side imaging. So far, single-layer plasma crystals of up to 15000 particles have been suspended. The particle velocity fluctuation spectra were measured and from these, the particle charge and screening length were calculated. Future experiments will explore the system-size dependence of the plasma crystal properties.
Lhermitte Sign After Chemo-IMRT of Head-and-Neck Cancer: Incidence, Doses, and Potential Mechanisms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pak, Daniel; Vineberg, Karen; Feng, Felix
2012-08-01
Purpose: We have observed a higher rate of Lhermitte sign (LS) after chemo-intensity-modulated radiotherapy (IMRT) of head-and-neck cancer than the published rates after conventional radiotherapy. We hypothesized that the inhomogeneous spinal cord dose distributions produced by IMRT caused a 'bath-and-shower' effect, characterized by low doses in the vicinity of high doses, reducing spinal cord tolerance. Methods and Materials: Seventy-three patients with squamous cell carcinoma of the oropharynx participated in a prospective study of IMRT concurrent with weekly carboplatin and paclitaxel. Of these, 15 (21%) reported LS during at least 2 consecutive follow-up visits. Mean dose, maximum dose, and partial volumemore » and absolute volume (in milliliters) of spinal cord receiving specified doses ({>=}10 Gy, {>=}20 Gy, {>=}30 Gy, and {>=}40 Gy), as well as the pattern of dose distributions at the 'anatomic' spinal cord (from the base of the skull to the aortic arch) and 'plan-related' spinal cord (from the top through the bottom of the planning target volumes), were compared between LS patients and 34 non-LS patients. Results: LS patients had significantly higher spinal cord mean doses, V{sub 30}, V{sub 40}, and absolute volumes receiving 30 Gy or more and 40 Gy or more compared with the non-LS patients (p < 0.05). The strongest predictors of LS were higher V{sub 40} and higher cord volumes receiving 40 Gy or more (p {<=} 0.007). There was no evidence of larger spinal cord volumes receiving low doses in the vicinity of higher doses (bath-and-shower effect) in LS compared with non-LS patients. Conclusions: Greater mean dose, V{sub 30}, V{sub 40}, and cord volumes receiving 30 Gy or more and 40 Gy or more characterized LS compared with non-LS patients. Bath-and-shower effects could not be validated in this study as a potential contributor to LS. The higher-than-expected rates of LS may be because of the specific concurrent chemotherapy agents or more accurate identification of LS in the setting of a prospective study.« less
NASA Astrophysics Data System (ADS)
Behrens, B.-A.; Bouguecha, A.; Vucetic, M.; Grbic, N.
2016-10-01
A structural concept in multi-material design is used in the automotive industry with the aim of achieving significant weight reductions of conventional car bodies. In this respect, the use of aluminum and short fiber reinforced plastics represents an interesting material combination. A wide acceptance of such a material combination requires a suitable joining technique. Among different joining techniques, clinching represents one of the most appealing alternative for automotive applications. This contribution deals with the FE simulation of the clinching process of two representative materials PA6GF30 and EN AW 5754 using the FE software LS-DYNA. With regard to the material modelling of the aluminum sheet, an isotropic material model based on the von Mises plasticity implemented in LS-DYNA was chosen. Analogous to aluminum, the same material model is used for modelling the short fiber reinforced thermoplastic. Additionally, a semi-analytical model for polymers (SAMP-1) also available in LS-DYNA was taken. Finally, the FEA of clinching process is carried out and the comparison of the simulation results is presented above.
Effect of liquid-to-solid ratio on semi-solid Fenton process in hazardous solid waste detoxication.
Hu, Li-Fang; Feng, Hua-Jun; Long, Yu-Yang; Zheng, Yuan-Ge; Fang, Cheng-Ran; Shen, Dong-Sheng
2011-01-01
The liquid-to-solid ratio (L/S) of semi-solid Fenton process (SSFP) designated for hazardous solid waste detoxication was investigated. The removal and minimization effects of o-nitroaniline (ONA) in simulate solid waste residue (SSWR) from organic arsenic industry was evaluated by total organic carbon (TOC) and ONA removal efficiency, respectively. Initially, Box-Behnken design (BBD) and response surface methodology (RSM) were used to optimize the key factors of SSFP. Results showed that the removal rates of TOC and ONA decreased as L/S increased. Subsequently, four target initial ONA concentrations including 100 mg kg(-1), 1 g kg(-1), 10 g kg(-1), and 100 gk g(-1) on a dry basis were evaluated for the effect of L/S. A significant cubic empirical model between the initial ONA concentration and L/S was successfully developed to predict the optimal L/S for given initial ONA concentration for SSFP. Moreover, an optimized operation strategy of multi-SSFP for different cases was determined based on the residual target pollutant concentration and the corresponding environmental conditions. It showed that the total L/S of multi-SSFP in all tested scenarios was no greater than 3.8, which is lower than the conventional slurry systems (L/S ≥ 5). The multi-SSFP is environment-friendly when it used for detoxication of hazardous solid waste contaminated by ONA and provides a potential method for the detoxication of hazardous solid waste contaminated by organics. Copyright © 2010 Elsevier Ltd. All rights reserved.
Lingohr, Philipp; Dohmen, Jonas; Matthaei, Hanno; Schwandt, Timo; Stein, Kathy; Hong, Gun-Soo; Steitz, Julia; Longerich, Thomas; Bölke, Edwin; Wehner, Sven; Kalff, Jörg C
2017-06-01
Laparoscopic surgery (LS) has proved superior compared to conventional surgery (CS) regarding morbidity, length of hospital stay, rate of wound infection and time until recovery. An improved preservation of the postoperative immune function is assumed to contribute to these benefits though the role of the local peritoneal immune response is still poorly understood. Our study investigates the peritoneal immune response subsequent to abdominal surgery and compares it between laparoscopic and conventional surgery to find an immunological explanation for the clinically proven benefits of LS. Wistar rats (N = 140) underwent laparoscopic cecum resection (LCR; N = 28), conventional cecum resection (CCR; N = 28), laparoscopic sham operation (LSO; N = 28), conventional sham operation (CSO; N = 28), or no surgical treatment (CTRL; N = 28). Postoperatively, peritoneal lavages were performed, leukocytes isolated and analyzed regarding immune function and phagocytosis activity. Immune function was inhibited postoperatively in animals undergoing LCR or CCR compared to CTRL reflected by a lower TNF-α (CTRL 3956.65 pg/ml, LCR 2018.48 pg/ml (p = 0.023), CCR 2793.78 pg/ml (n.s.)) and IL-6 secretion (CTRL 625.84 pg/ml, LCR 142.84 pg/ml (p = 0.009), CCR 169.53 pg/ml (p = 0.01)). Phagocytosis was not affected in rats undergoing any kind of surgery compared to CTRL. Neither cytokine secretion nor phagocytosis activity differed significantly between laparoscopic and conventional surgery. According to our findings the benefits associated with LS compared to CS cannot be explained by differences in the postoperative peritoneal innate immune response. Further studies are needed to elucidate the causes for a more favorable postoperative outcome in patients after LS compared to CS.
Cnossen, Fokie; Dieperink, Willem; Bult, Wouter; de Smet, Anne Marie; Touw, Daan J.; Nijsten, Maarten W.
2017-01-01
The objective of this study was to assess the usability benefits of adding a bedside central control interface that controls all intravenous (IV) infusion pumps compared to the conventional individual control of multiple infusion pumps. Eighteen dedicated ICU nurses volunteered in a between-subjects task-based usability test. A newly developed central control interface was compared to conventional control of multiple infusion pumps in a simulated ICU setting. Task execution time, clicks, errors and questionnaire responses were evaluated. Overall the central control interface outperformed the conventional control in terms of fewer user actions (40±3 vs. 73±20 clicks, p<0.001) and fewer user errors (1±1 vs. 3±2 errors, p<0.05), with no difference in task execution times (421±108 vs. 406±119 seconds, not significant). Questionnaires indicated a significant preference for the central control interface. Despite being novice users of the central control interface, ICU nurses displayed improved performance with the central control interface compared to the conventional interface they were familiar with. We conclude that the new user interface has an overall better usability than the conventional interface. PMID:28800617
Doesburg, Frank; Cnossen, Fokie; Dieperink, Willem; Bult, Wouter; de Smet, Anne Marie; Touw, Daan J; Nijsten, Maarten W
2017-01-01
The objective of this study was to assess the usability benefits of adding a bedside central control interface that controls all intravenous (IV) infusion pumps compared to the conventional individual control of multiple infusion pumps. Eighteen dedicated ICU nurses volunteered in a between-subjects task-based usability test. A newly developed central control interface was compared to conventional control of multiple infusion pumps in a simulated ICU setting. Task execution time, clicks, errors and questionnaire responses were evaluated. Overall the central control interface outperformed the conventional control in terms of fewer user actions (40±3 vs. 73±20 clicks, p<0.001) and fewer user errors (1±1 vs. 3±2 errors, p<0.05), with no difference in task execution times (421±108 vs. 406±119 seconds, not significant). Questionnaires indicated a significant preference for the central control interface. Despite being novice users of the central control interface, ICU nurses displayed improved performance with the central control interface compared to the conventional interface they were familiar with. We conclude that the new user interface has an overall better usability than the conventional interface.
NASA Astrophysics Data System (ADS)
Chen, Ching-Hsu; Lu, Ming-Lun; Tai, Po-Tse
2015-08-01
We determine the average path length ls of amplified spontaneous emission (ASE) by comparing the numerical slope of a straight line with the experimental slope in the graph of the square of relaxation oscillation frequency versus normalized pump ratio. The simple method is applied in an end-pumped Nd:YVO4 laser with the 1/3 mode-degeneracy cavity having the transverse mode spacing equal to 1/3 of the longitudinal mode spacing. We find that ls is larger at the degeneracy than that far from the degeneracy. This result indicates the existence of stronger ASE at the degeneracy, which is confirmed below the threshold. This is because many spontaneous emission photons can undergo amplification not only before escaping from the gain medium but also after leaving the gain medium, owing to cavity reflection. Our method can be applied in the situations where the Auger upconversion effect is absent, weak, or well-known.
Alternative Fuels Data Center: Blender Pump Dispensers
... Blender Pump Dispensers Updated April 2, 2012 Federal and local initiatives to increase the use of ethanol choose the blend of fuel they want to use based on price, their vehicle's fuel economy, and other factors blends of those two fuels. Many conventional stations today use blender pump dispensers to generate
Chen, Menghao; Parsons, Andrew J; Felfel, Reda M; Rudd, Christopher D; Irvine, Derek J; Ahmed, Ifty
2016-06-01
Fully bioresorbable composites have been investigated in order to replace metal implant plates used for hard tissue repair. Retention of the composite mechanical properties within a physiological environment has been shown to be significantly affected due to loss of the integrity of the fibre/matrix interface. This study investigated phosphate based glass fibre (PGF) reinforced polycaprolactone (PCL) composites with 20%, 35% and 50% fibre volume fractions (Vf) manufactured via an in-situ polymerisation (ISP) process and a conventional laminate stacking (LS) followed by compression moulding. Reinforcing efficiency between the LS and ISP manufacturing process was compared, and the ISP composites revealed significant improvements in mechanical properties when compared to LS composites. The degradation profiles and mechanical properties were monitored in phosphate buffered saline (PBS) at 37°C for 28 days. ISP composites revealed significantly less media uptake and mass loss (p<0.001) throughout the degradation period. The initial flexural properties of ISP composites were substantially higher (p<0.0001) than those of the LS composites, which showed that the ISP manufacturing process provided a significantly enhanced reinforcement effect than the LS process. During the degradation study, statistically higher flexural property retention profiles were also seen for the ISP composites compared to LS composites. SEM micrographs of fracture surfaces for the LS composites revealed dry fibre bundles and poor fibre dispersion with polymer rich zones, which indicated poor interfacial bonding, distribution and adhesion. In contrast, evenly distributed fibres without dry fibre bundles or polymer rich zones, were clearly observed for the ISP composite samples, which showed that a superior fibre/matrix interface was achieved with highly improved adhesion. Copyright © 2015 Elsevier Ltd. All rights reserved.
Qin, Yuxuan; Shang, Qingmao; Zhang, Ying; Li, Pinglan; Chai, Yunrong
2017-01-01
Vegetable plug seedling has become the most important way to produce vegetable seedlings in China. This seedling method can significantly improve the quality and yield of vegetables compared to conventional methods. In the process of plug seedling, chemical fertilizers or pesticides are often used to improve the yield of the seedlings albeit with increasing concerns. Meanwhile, little is known about the impact of beneficial bacteria on the rhizosphere microbiota and the growth conditions of vegetables during plug seedling. In this study, we applied a culture-independent next-generation sequencing-based approach and investigated the impact of a plant beneficial bacterium, Bacillus amyloliquefaciens L-S60, on the composition and dynamics of rhizosphere microbiota and the growth conditions of cucumbers during plug seedling. Our results showed that application of L-S60 significantly altered the structure of the bacterial community associated with the cucumber seedling; presence of beneficial rhizosphere species such as Bacillus, Rhodanobacter, Paenibacillus, Pseudomonas, Nonomuraea, and Agrobacterium was higher upon L-S60 treatment than in the control group. We also measured the impact of L-S60 application on the physiological properties of the cucumber seedlings as well as the availability of main mineral elements in the seedling at different time points during the plug seedling. Results from those measurements indicated that L-S60 application promoted growth conditions of cucumber seedlings and that more available mineral elements were detected in the cucumber seedlings from the L-S60 treated group than from the control group. The findings in this study provided evidence for the beneficial effects of plant growth-promoting rhizosphere bacteria on the bacterial community composition and growth conditions of the vegetables during plug seedling. PMID:29312278
Buckley, Thomas N; Roberts, David W
2006-02-01
Conventional wisdom holds that the ratio of leaf area to sapwood area (L/S) should decline during height (H) growth to maintain hydraulic homeostasis and prevent stomatal conductance (g(s)) from declining. We contend that L/S should increase with H based on a numerical simulation, a mathematical analysis and a conceptual argument: (1) numerical simulation--a tree growth model, DESPOT (Deducing Emergent Structure and Physiology Of Trees), in which carbon (C) allocation is regulated to maximize C gain, predicts L/S should increase during most of H growth; (2) mathematical analysis--the formal criterion for optimal C allocation, applied to a simplified analytical model of whole tree carbon-water balance, predicts L/S should increase with H if leaf-level gas exchange parameters including g(s) are conserved; and (3) conceptual argument--photosynthesis is limited by several substitutable resources (chiefly nitrogen (N), water and light) and H growth increases the C cost of water transport but not necessarily of N and light capture, so if the goal is to maximize C gain or growth, allocation should shift in favor of increasing photosynthetic capacity and irradiance, rather than sustaining g(s). Although many data are consistent with the prediction that L/S should decline with H, many others are not, and we discuss possible reasons for these discrepancies.
Shah, Amil M.; Claggett, Brian; Sweitzer, Nancy K.; Shah, Sanjiv J.; Anand, Inder S.; Liu, Li; Pitt, Bertram; Pfeffer, Marc A.; Solomon, Scott D.
2015-01-01
Background Impairment in left ventricular (LV) systolic function has been described in heart failure with preserved ejection fraction (HFpEF), but its prognostic relevance is not known. We determined whether LV longitudinal strain (LS) is predictive of cardiovascular (CV) outcomes in HFpEF beyond clinical and conventional echocardiographic measures. Methods and Results LS was assessed by 2D speckle-tracking echocardiography at baseline in 447 HFpEF patients enrolled in the Treatment Of Preserved Cardiac Function Heart Failure with an Aldosterone Antagonist (TOPCAT) trial. At a median follow-up of 2.6 (IQR 1.5–3.9) years, 115 patients experienced the primary composite outcome of CV death, HF hospitalization, or aborted cardiac arrest. Impaired LS, defined as an absolute LS<15.8%, was present in 52% of patients and was predictive of the composite outcome (adjusted HR 2.14, 95% CI 1.26–3.66; p=0.005), CV death alone (adjusted HR 3.20, 95% CI 1.44–7.12; p=0.004), and HF hospitalization alone (adjusted HR 2.23, 95% CI 1.16–4.28; p=0.016) after adjusting for clinical and conventional echocardiographic variables. LS was the strongest echocardiographic predictor of the composite outcome. Exploratory analysis in a subset of 131 patients with follow-up LS assessed after 12–18 months demonstrated a trend towards improvement in LS associated with spironolactone in patients enrolled in the Americas but not in Russia or Georgia. Conclusions Impaired LV systolic function is a powerful predictor of HF hospitalization, CV death, or aborted cardiac arrest in HFpEF, independent of clinical predictors. Impaired LS represents a novel imaging biomarker to identify HFpEF patients at particularly high risk for CV morbidity and mortality. Clinical Trial Registration Information Clinicaltrials.gov. Identifier NCT00094302. PMID:26130119
Design of a cross-connected charge pump for energy harvesting systems
NASA Astrophysics Data System (ADS)
Eguchi, K.; Fujisaki, H.; Asadi, F.; Oota, I.
2018-03-01
For energy harvesting systems, a novel charge pump with cross-connected structure is proposed in this paper. Owing to the cross-connected structure, the proposed charge pump can offer the output voltage to the output load at every phase. Furthermore, the proposed charge pump can reduce the number of circuit stages from the conventional charge pump. For above-mentioned reasons, the proposed charge pump can realize not only smaller internal resistance but also smaller output capacitance than the conventional charge pump. The theoretical analysis and simulation program with integrated circuit emphasis (SPICE) simulation demonstrate that the proposed charge pump outperforms the conventional charge pump in the point of power efficiency and circuit speed.
NASA Astrophysics Data System (ADS)
Dragoni, W.; Mottola, A.; Cambi, C.
2013-06-01
One of the techniques used to increase the water yield of springs during dry seasons and droughts is drilling wells close to them. Where there is a low-hydraulic conductivity boundary close to a spring (the case considered here), this technique implies low well efficiency, high drawdown, and high cost of withdrawals. In addition, a set of pumping wells close to a spring can cause both it and the stream originating from it to dry up - a situation which is not always acceptable from an environmental point of view. In order to study better management strategies, this paper presents a finite difference model of the Scirca spring (Umbria - Marche Apennines, Italy), which originates from a limestone massif in which some formations are karstified. The model, built with Modflow using the equivalent porous media (EPM) approach, simulated the effects of pumping wells at various distances from the spring. Hydraulic Conductivity and Storativity were calibrated and validated on discharge data during recession, when recharge is nil. "Inverse modeling" was then used to estimate the daily recharge of the hydro-geological system of the Scirca spring for a period of several years. Lastly, the efficiency of various management schemes was evaluated by simulating the reaction of the spring, in terms of discharge, to a series of pumping scenarios, all guaranteeing a certain imposed withdrawal during summer, much larger than the natural spring discharge, given by spring discharge and well drawdown. The wells were located between 2850 and 100 m from the spring, the pumping time-span was set at 90 days, and pumping rates of 60, 90 and 120 l/s were applied. Results show that the maximum discharge at which spring drainage is avoided and that minimum vital flow is guaranteed is 90 l/s. The higher water volumes extracted during summer (dry season) are balanced by a lowering of the maximum natural discharges in winter and spring (recharge seasons). Simulations indicate that, by drilling pumping wells far from the spring, the efficiency of the whole system can be optimized in terms of total withdrawal, drilling and management costs, with reduced environmental impact. The mathematical model also shows how long the system takes to regain its "undisturbed" state, with a tolerance of 0.5 l/s. The model highlights the possibility of forcing the system to supply a smaller amount of water in winter, in order to increase the summer yield. Such a management scheme, which can be applied to other springs, may be useful in better meeting the demand for water during dry seasons.
Zhou, Ping; Guo, Dongwei; Wang, Hong; Chai, Tianyou
2017-09-29
Optimal operation of an industrial blast furnace (BF) ironmaking process largely depends on a reliable measurement of molten iron quality (MIQ) indices, which are not feasible using the conventional sensors. This paper proposes a novel data-driven robust modeling method for the online estimation and control of MIQ indices. First, a nonlinear autoregressive exogenous (NARX) model is constructed for the MIQ indices to completely capture the nonlinear dynamics of the BF process. Then, considering that the standard least-squares support vector regression (LS-SVR) cannot directly cope with the multioutput problem, a multitask transfer learning is proposed to design a novel multioutput LS-SVR (M-LS-SVR) for the learning of the NARX model. Furthermore, a novel M-estimator is proposed to reduce the interference of outliers and improve the robustness of the M-LS-SVR model. Since the weights of different outlier data are properly given by the weight function, their corresponding contributions on modeling can properly be distinguished, thus a robust modeling result can be achieved. Finally, a novel multiobjective evaluation index on the modeling performance is developed by comprehensively considering the root-mean-square error of modeling and the correlation coefficient on trend fitting, based on which the nondominated sorting genetic algorithm II is used to globally optimize the model parameters. Both experiments using industrial data and industrial applications illustrate that the proposed method can eliminate the adverse effect caused by the fluctuation of data in BF process efficiently. This indicates its stronger robustness and higher accuracy. Moreover, control testing shows that the developed model can be well applied to realize data-driven control of the BF process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Ping; Guo, Dongwei; Wang, Hong
Optimal operation of an industrial blast furnace (BF) ironmaking process largely depends on a reliable measurement of molten iron quality (MIQ) indices, which are not feasible using the conventional sensors. This paper proposes a novel data-driven robust modeling method for the online estimation and control of MIQ indices. First, a nonlinear autoregressive exogenous (NARX) model is constructed for the MIQ indices to completely capture the nonlinear dynamics of the BF process. Then, considering that the standard least-squares support vector regression (LS-SVR) cannot directly cope with the multioutput problem, a multitask transfer learning is proposed to design a novel multioutput LS-SVRmore » (M-LS-SVR) for the learning of the NARX model. Furthermore, a novel M-estimator is proposed to reduce the interference of outliers and improve the robustness of the M-LS-SVR model. Since the weights of different outlier data are properly given by the weight function, their corresponding contributions on modeling can properly be distinguished, thus a robust modeling result can be achieved. Finally, a novel multiobjective evaluation index on the modeling performance is developed by comprehensively considering the root-mean-square error of modeling and the correlation coefficient on trend fitting, based on which the nondominated sorting genetic algorithm II is used to globally optimize the model parameters. Both experiments using industrial data and industrial applications illustrate that the proposed method can eliminate the adverse effect caused by the fluctuation of data in BF process efficiently. In conclusion, this indicates its stronger robustness and higher accuracy. Moreover, control testing shows that the developed model can be well applied to realize data-driven control of the BF process.« less
Zhou, Ping; Guo, Dongwei; Wang, Hong; ...
2017-09-29
Optimal operation of an industrial blast furnace (BF) ironmaking process largely depends on a reliable measurement of molten iron quality (MIQ) indices, which are not feasible using the conventional sensors. This paper proposes a novel data-driven robust modeling method for the online estimation and control of MIQ indices. First, a nonlinear autoregressive exogenous (NARX) model is constructed for the MIQ indices to completely capture the nonlinear dynamics of the BF process. Then, considering that the standard least-squares support vector regression (LS-SVR) cannot directly cope with the multioutput problem, a multitask transfer learning is proposed to design a novel multioutput LS-SVRmore » (M-LS-SVR) for the learning of the NARX model. Furthermore, a novel M-estimator is proposed to reduce the interference of outliers and improve the robustness of the M-LS-SVR model. Since the weights of different outlier data are properly given by the weight function, their corresponding contributions on modeling can properly be distinguished, thus a robust modeling result can be achieved. Finally, a novel multiobjective evaluation index on the modeling performance is developed by comprehensively considering the root-mean-square error of modeling and the correlation coefficient on trend fitting, based on which the nondominated sorting genetic algorithm II is used to globally optimize the model parameters. Both experiments using industrial data and industrial applications illustrate that the proposed method can eliminate the adverse effect caused by the fluctuation of data in BF process efficiently. In conclusion, this indicates its stronger robustness and higher accuracy. Moreover, control testing shows that the developed model can be well applied to realize data-driven control of the BF process.« less
Spatial emission distribution of InGaN/GaN light-emitting diodes depending on the pattern structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Kwanjae; Lee, Hyunjung; Lee, Cheul-Ro
2014-10-15
Highlights: • We study carrier lifetimes of InGaN/GaN LEDs fabricated on different PSS. • Spatial EL distribution was investigated depending on the pattern structure. • The carrier lifetime of the LEDs was compared with the spatial EL distribution. - Abstract: We investigated the emission characteristics of InGaN/GaN light-emitting diodes (LEDs) fabricated on lens-shaped (LS) patterned-sapphire substrates (PSS) by using time-resolved photoluminescence (TRPL) and confocal-scanning-electroluminescence microscopy (CSEM). The carrier lifetimes evaluated from the TRPL spectra for the LEDs on the LS-PSS (LS-LEDs) at 10 K were relatively shorter than those of the LEDs on a conventional planar substrate (C-LED). However, themore » carrier lifetimes for the LS-LEDs were relatively long compared to that of the C-LED at room temperature. In the CSEM images of the LS-LEDs, the emission beam around the center region of the LS pattern was relatively weaker than that of the edge region. In addition, the beam profile for the LS-LEDs showed different shapes according to the pattern structures. The emission beam around the boundary region of the LS pattern showed periodic fluctuation with the peak-to-peak distance of 814 nm.« less
Less Is More: Efficacy of Rapid 3D-T2 SPACE in ED Patients with Acute Atypical Low Back Pain.
Koontz, Nicholas A; Wiggins, Richard H; Mills, Megan K; McLaughlin, Michael S; Pigman, Elaine C; Anzai, Yoshimi; Shah, Lubdha M
2017-08-01
Emergency department (ED) patients with acute low back pain (LBP) may present with ambiguous clinical findings that pose diagnostic challenges to exclude cauda equina syndrome (CES). As a proof of concept, we aimed to determine the efficacy of a rapid lumbar spine (LS) magnetic resonance imaging (MRI) screening protocol consisting of a single 3D-T2 SPACE FS (3D-T2 Sampling Perfection with Application optimized Contrasts using different flip angle Evolution fat saturated) sequence relative to conventional LS MRI to exclude emergently treatable pathologies in this complex patient population. LS MRI protocol including a sagittal 3D-T2 SPACE FS pulse sequence was added to the routine for ED patients presenting with acute atypical LBP over a 12-month period. Imaging findings were categorically scored on the 3D-T2 SPACE FS sequence and separately on the reference standard conventional LS MRI sequences. Patients' symptoms were obtained from review of the electronic medical record. Descriptive test statistics were performed. Of the 206 ED patients who obtained MRI for acute atypical LBP, 118 (43.3 ± 13.5 years of age; 61 female) were included. Specific pathologies detected on reference standard conventional MRI included disc herniation (n = 30), acute fracture (n = 3), synovial cyst (n = 3), epidural hematoma (n = 2), cerebrospinal fluid leak (n = 1), and leptomeningeal metastases (n = 1), and on multiple occasions these pathologies resulted in nerve root impingement (n = 36), severe spinal canal stenosis (n = 13), cord/conus compression (n = 2), and cord signal abnormality (n = 2). The 3D-T2 SPACE FS sequence was an effective screen for fracture (sensitivity [sens] = 100%, specificity [spec] = 100%), cord signal abnormality (sens = 100%, spec = 99%), and severe spinal canal stenosis (sens = 100%, spec = 96%), and identified cord compression not seen on reference standard. Motion artifact was not seen on the 3D-T2 SPACE FS but noted on 8.5% of conventional LS MRI. The 3D-T2 SPACE FS sequence MRI is a rapid, effective screen for emergently actionable pathologies that might be a cause of CES in ED patients presenting with acute atypical LBP. As this abbreviated, highly sensitive sequence requires a fraction of the acquisition time of conventional LS MRI, it has the potential of contributing to increased efficiencies in the radiology department and improved ED throughput. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Development of cryosorption panels for cryopumps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perinic, D.; Haas, H.; Mack, A.
1994-12-31
Liquid-helium cooled cryosorption panels have been developed in Karlsruhe for plasma exhaust pumping in tokamaks. A variety of material combinations (sorbent/bonding/substrate) and various coating techniques have been compared in an extensive testing programme. A technology suitable for machine coating of large surfaces has been developed applying injector nozzles for spraying of bonding and sorbent materials. Inorganic cements have been selected for bonding activated carbon or molecular sieve particles, 10 {mu}m to 2 mm grain size, to metal substrates. The cryosorption panels prepared in this way are capable of pumping simulated tokamak exhaust gas mixtures including deuterium, helium and impurities atmore » pumping speeds of up to 8 L/(s cm{sup 2}) and pumping pressures < 10{sup {minus}2} mbar. In this paper the development of the coating technology and some results of panel testing are described.« less
NASA Astrophysics Data System (ADS)
Vanheyden, L.; Evertz, E.
1980-12-01
Compression type air/water heat pumps were developed for domestic heating systems rated at 20 to 150 kW. The heat pump is driven either by a reciprocating piston or rotary piston engine modified to operate on natural gas. Particular features of natural gas engines as prime movers, such as waste heat recovery and variable speed, are stressed. Two systems suitable for heat pump operation were selected from among five different mass produced car engines and were modified to incorporate reciprocating piston compressor pairs. The refrigerants used are R 12 and R 22. Test rig data transferred to field conditions show that the fuel consumption of conventional boilers can be reduced by 50% and more by the installation of engine driven heat pumps. Pilot heat pumps based on a 1,600 cc reciprocating piston engine were built for heating four two-family houses. Pilot pump operation confirms test rig findings. The service life of rotary piston and reciprocating piston engines was investigated. The tests reveal characteristic curves for reciprocating piston engines and include exhaust composition measurements.
Jiang, Cuiping; Zhao, Yi; Yang, Yun; He, Jianhua; Zhang, Wenli; Liu, Jianping
2018-03-05
Recombinant high-density lipoprotein (rHDL) displays a similar anti-atherosclerotic effect with native HDL and could also be served as a carrier of cardiovascular drug for atherosclerotic plaque targeting. In our previous studies, rHDL has shown a more potent anti-atherosclerotic efficacy as compared to the other conventional nanoparticles with a payload of lovastatin (LS). Therefore, we hypothesized that a synergistic anti-atherosclerotic effect of the rHDL carrier and the encapsulated LS might exist. In this study, the dose-effect relationships and the combined effect of the rHDL and LS were quantitatively evaluated in RAW 264.7 macrophage cells using the median-effect analysis, in which the rHDL carrier was regarded as a drug combined. Median-effect analysis suggested that rHDL and LS exerted a desirable synergistic inhibition on the oxLDL internalization at a ratio of 6:1 ( D m,LS : D m,rHDL ) in RAW 264.7 macrophage cells. About 50% of the reduction on the intracellular lipid contents was found when RAW264.7 cells were treated with LS-loaded rHDLs at their respective median-effect dose ( D m ) concentrations and a synergistic effect on the mediating cholesterol efflux was also observed, which verified the accuracy of the results obtained from the median-effect analysis. The mechanism underlying the synergistic effect of the rHDL carrier and the drug might be attributed to their potent inhibitory effects on SR-A expression. In conclusion, the median-effect analysis was proven to be a feasible method to quantitatively evaluate the synergistic effect of the biofunctional carrier and the drug encapsulated.
Performance of an Annular Linear Induction Pump with Applications to Space Nuclear Power Systems
NASA Technical Reports Server (NTRS)
Polzin, Kurt A.; Schoenfeld, Michael; Pearson, J. Boise; Webster, Kenneth; Godfroy, Thomas; Adkins, Harold E., Jr.; Werner, James E.
2010-01-01
Results of performance testing of an annular linear induction pump are presented. The pump electromagnetically pumps liquid metal through a circuit specially designed to allow for quantification of the performance. Testing was conducted over a range of conditions, including frequencies of 33, 36, 39, and 60 Hz, liquid metal temperatures from 125 to 525 C, and input voltages from 5 to 120 V. Pump performance spanned a range of flow rates from roughly 0.16 to 5.7 L/s (2.5 to 90 gpm), and pressure head less than 1 to 90 kPa (less than 0.145 to 13 psi). The maximum efficiency measured during testing was slightly greater than 6%. The efficiency was fairly insensitive to input frequency from 33 to 39 Hz, and was markedly lower at 60 Hz. In addition, the efficiency decreased as the NaK temperature was raised. The performance of the pump operating on a variable frequency drive providing 60 Hz power compared favorably with the same pump operating on 60 Hz power drawn directly from the electrical grid.
Kaul, Michael Gerhard; Mummert, Tobias; Jung, Caroline; Salamon, Johannes; Khandhar, Amit P; Ferguson, R Matthew; Kemp, Scott J; Ittrich, Harald; Krishnan, Kannan M; Adam, Gerhard; Knopp, Tobias
2017-05-07
Optimizing tracers for individual imaging techniques is an active field of research. The purpose of this study was to perform in vitro and in vivo magnetic particle imaging (MPI) measurements using a new monodisperse and size-optimized tracer, LS-008, and to compare it with the performance of Resovist, the standard MPI tracer. Magnetic particle spectroscopy (MPS) and in vitro MPI measurements were performed in concerns of concentration and amount of tracer in a phantom. In vivo studies were carried out in healthy FVB mice. The first group (n = 3) received 60 µl LS-008 (87 mM) and the second (n = 3) diluted Resovist of the same concentration and volume. Tracer injections were performed with a syringe pump during a dynamic MPI scan. For anatomic referencing MRI was applied beforehand of the MPI measurements. Summing up MPS examinations and in vitro MPI experiments, LS-008 showed better sensitivity and spatial resolution than Resovist. In vivo both tracers can visualize the propagation of the bolus through the inferior vena cava. MPI with LS-008 did show less temporal fluctuation artifacts and the pulsation of blood due to respiratory and cardiac cycle was detectable. With LS-008 the aorta was distinguishable from the caval vein while with Resovist this failed. A liver vessel and a vessel structure leading cranially could only be observed with LS-008 and not with Resovist. Beside these structural advantages both tracers showed very different blood half-life. For LS-008 we found 88 min. Resovist did show a fast liver accumulation and a half-life of 13 min. Only with LS-008 the perfusion fraction in liver and kidney was measureable. MPI for angiography can be significantly improved by applying more effective tracers. LS-008 shows a clear improvement concerning the delineation while resolving a larger number of vessels in comparison to Resovist. Therefore, in aspects of quality and quantity LS-008 is clearly favorable for angiographic and perfusion studies.
NASA Astrophysics Data System (ADS)
Kaul, Michael Gerhard; Mummert, Tobias; Jung, Caroline; Salamon, Johannes; Khandhar, Amit P.; Ferguson, R. Matthew; Kemp, Scott J.; Ittrich, Harald; Krishnan, Kannan M.; Adam, Gerhard; Knopp, Tobias
2017-05-01
Optimizing tracers for individual imaging techniques is an active field of research. The purpose of this study was to perform in vitro and in vivo magnetic particle imaging (MPI) measurements using a new monodisperse and size-optimized tracer, LS-008, and to compare it with the performance of Resovist, the standard MPI tracer. Magnetic particle spectroscopy (MPS) and in vitro MPI measurements were performed in concerns of concentration and amount of tracer in a phantom. In vivo studies were carried out in healthy FVB mice. The first group (n = 3) received 60 µl LS-008 (87 mM) and the second (n = 3) diluted Resovist of the same concentration and volume. Tracer injections were performed with a syringe pump during a dynamic MPI scan. For anatomic referencing MRI was applied beforehand of the MPI measurements. Summing up MPS examinations and in vitro MPI experiments, LS-008 showed better sensitivity and spatial resolution than Resovist. In vivo both tracers can visualize the propagation of the bolus through the inferior vena cava. MPI with LS-008 did show less temporal fluctuation artifacts and the pulsation of blood due to respiratory and cardiac cycle was detectable. With LS-008 the aorta was distinguishable from the caval vein while with Resovist this failed. A liver vessel and a vessel structure leading cranially could only be observed with LS-008 and not with Resovist. Beside these structural advantages both tracers showed very different blood half-life. For LS-008 we found 88 min. Resovist did show a fast liver accumulation and a half-life of 13 min. Only with LS-008 the perfusion fraction in liver and kidney was measureable. MPI for angiography can be significantly improved by applying more effective tracers. LS-008 shows a clear improvement concerning the delineation while resolving a larger number of vessels in comparison to Resovist. Therefore, in aspects of quality and quantity LS-008 is clearly favorable for angiographic and perfusion studies.
NASA Astrophysics Data System (ADS)
Butymova, L. N.; Modorskii, V. Ya.
2017-10-01
To ensure contactless sealing of the connection between the rotating rotor and the stationary body in aircraft engines [16], high pressure pumps [13, 14], etc., labyrinth seals (LS) are used. In labyrinth seals, the working medium is sealed by throttling it when moving through successive constrictions and expansions. The study of throttling is usually performed when investigating the gas flow in the direction parallel to the rotor axis. However, it was shown in [1] that the wave processes occurring in the circumferential direction of the labyrinth seals during the vibrations of the rotor contribute to the formation of gas dynamic oscillatory processes. It should be noted that sequencing of the constrictions and extensions affects the oscillation amplitude in the gas-dynamic cavity between the LS and the rotor and increases the flow unevenness. Consequently, if these elements are not taken into account in aeroelastic calculation [15, 21] it can give an additional margin of reducing oscillations in LS and, which is important, to solve related problems [18] of continuous media mechanics [19], reduce labor intensity and counting time. Thus, in accordance with the foregoing, the LS calculation is replaced with calculating the gap seal, equivalent (with margin) to the labyrinth seal, if we consider the processes occurring in the LS circumferential direction.
NASA Technical Reports Server (NTRS)
Polzin, K. A.; Pearson, J. B.; Webster, K.; Godfoy, T. J.; Bossard, J. A.
2013-01-01
Results of performance testing of an annular linear induction pump that has been designed for integration into a fission surface power technology demonstration unit are presented. The pump electromagnetically pushes liquid metal (NaK) through a specially-designed apparatus that permits quantification of pump performance over a range of operating conditions. Testing was conducted for frequencies of 40, 55, and 70 Hz, liquid metal temperatures of 125, 325, and 525 C, and input voltages from 30 to 120 V. Pump performance spanned a range of flow rates from roughly 0.3 to 3.1 L/s (4.8 to 49 gpm), and pressure heads of <1 to 104 kPa (<0.15 to 15 psi). The maximum efficiency measured during testing was 5.4%. At the technology demonstration unit operating temperature of 525 C the pump operated over a narrower envelope, with flow rates from 0.3 to 2.75 L/s (4.8 to 43.6 gpm), developed pressure heads from <1 to 55 kPa (<0.15 to 8 psi), and a maximum efficiency of 3.5%. The pump was supplied with three-phase power at 40 and 55 Hz using a variable-frequency motor drive, while power at 55 and 70 Hz was supplied using a variable-frequency power supply. Measured performance of the pump at 55 Hz using either supply exhibited good quantitative agreement. For a given temperature, the peak in efficiency occurred at different flow rates as the frequency was changed, but the maximum value of efficiency was relative insensitive within 0.3% over the frequency range tested, including a scan from 45 to 78 Hz. The objectives of the FSP technology project are as follows:5 • Develop FSP concepts that meet expected surface power requirements at reasonable cost with added benefits over other options. • Establish a nonnuclear hardware-based technical foundation for FSP design concepts to reduce overall development risk. • Reduce the cost uncertainties for FSP and establish greater credibility for flight system cost estimates. • Generate the key nonnuclear products to allow Agency decision makers to consider FSP as a viable option for potential future flight development. The pump must be compatible with the liquid NaK coolant and have adequate performance to enable a viable flight system. Idaho National Laboratory (INL) was tasked with the design and fabrication of an ALIP suitable for the FSP reference mission. Under the program, a quarter-scale FSP technology demonstration is under construction to test the end-to-end conversion of simulated nuclear thermal power to usable electrical power intended to raise the entire FSP system to Technology Readiness Level 6. An ALIP for this TDU was fabricated under the direction of the INL and shipped to NASA Marshall Space Flight Center (MSFC) for testing at representative operating conditions. This pump was designed to meet the requirements of the TDU experiment. The ALIP test circuit (ATC) at MSFC, previously used to conduct performance evaluation on another ALIP6 was used to test the present TDU pump for the FSP Technology Development program.
Kiuchi, Ryuta; Tomita, Shigeyuki; Yamaguchi, Shojiro; Nishida, Yuji; Ohtake, Hiroshi; Nakamura, Hiroyuki; Watanabe, Go
2014-07-01
It is important for coronary active perfusion systems to avoid myocardial ischemia during off-pump coronary artery bypass grafting. We have developed a new concept for a perfusion system to pump blood based on changes in helium gas volume. This system uses a conventional intra-aortic balloon pump to activate the perfusion pump. Our study used basic and animal experiments to investigate the most suitable system for coronary perfusion using this new concept. A conventional intra-aortic balloon pump was used to supply power. A device for perfusion was developed with a balloon placed inside a stiff syringe barrel. The device was connected to the helium gas line of the intra-aortic balloon pump. Changes in flow with changes in augmentation level were noted when volumes outside and within the balloon were changed. Six pigs with occlusion of the left anterior descending artery were used for system validation, with monitoring to identify changes in hemodynamics and cardiac enzyme levels. In the basic experiment, an 80-mL outside volume and 3.0-mL inner volume resulted in the greatest percentage change in flow rate with respect to changes in augmentation. In the animal experiment, the new coronary active perfusion system prevented myocardial ischemia during coronary occlusion. We clarified the most suitable method for our new coronary active perfusion system. Using this system, safe anastomosis was consistently performed in animal experiments. Clinically, off-pump coronary artery bypass may potentially be performed more safely and easily using this new system. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Outcome of Cardiac Rehabilitation Following Off-Pump Versus On-Pump Coronary Bypass Surgery.
Arefizadeh, Reza; Hariri, Seyed Yaser; Moghadam, Adel Johari
2017-06-15
A few studies have compared the cardiac rehabilitation (CR) outcome between those who undergo conventional on-pump bypass surgery and off-pump surgery. We compared this outcome among the patients differentiated by the On-pump and off-pump surgical procedures about cardiovascular variables and psychological status. This longitudinal study recruited 318 and 102 consecutive patients who had undergone CABG (on-pump surgery, n = 318 and off-pump surgery, n = 102) and been referred to the CR clinic. The off-pump surgery patients had more improvement in their metabolic equivalents (METs) value. The physical and mental components of health-related quality of life (QOL) (based on SF-36 questionnaire) as well as depression-anxiety (based on Costello-Comrey Depression and Anxiety Scale) were notably improved in the two study groups after the CR program, while changes in the QOL components scores and also depression-anxiety score were not different between the off-pump and on-pump techniques. Regarding QOL and psychological status, there were no differences in the CR outcome between those who underwent off-pump bypass surgery and those who underwent on-pump surgery; nevertheless, the off-pump technique was superior to the on-pump method on METs improvement following CR.
Mills, Anne M; Sloan, Emily A; Thomas, Martha; Modesitt, Susan C; Stoler, Mark H; Atkins, Kristen A; Moskaluk, Christopher A
2016-02-01
Expanded testing for Lynch syndrome (LS) is increasingly recommended for patients with endometrial carcinomas, and immunohistochemistry (IHC) for tumor loss of mismatch-repair (MMR) protein expression is the most common primary screen. This has led to the recognition of MMR-IHC-deficient cases without identifiable mutations on directed germline sequencing. The clinical implications of such "Lynch-like" (LL) cancers are unclear. We here report the clinicopathologic features of putative familial endometrial carcinoma identified on universal MMR-IHC screening with attention to cases with discordant IHC and germline results. The files of the University of Virginia Pathology Department were retrospectively searched for all MMR-deficient endometrial carcinomas identified on screening. Cases were categorized as likely sporadic (MLH1/PMS2 loss, evidence of MLH1 promoter hypermethylation) or putative LS (PLS) (loss of MSH2/MSH6, MSH6, or PMS2). PLS cases were further subdivided into LS and LL groups on the basis of the presence or absence of a confirmatory mutation by germline testing, and the clinicopathologic features of these cases were compared. A deficiency of ≥1 MMR protein was observed in 31.4% (66/210) of endometrial carcinomas, including 26 PLS cases, 15 of which had germline testing. Directed germline sequencing confirmed LS in 46.7% (7/15); the remaining cases were classified as LL. High-grade and/or biphasic morphology was seen in 42.9% (3/7) of LS and 62.5% (5/8) of LL cases; the remaining cases showed low-grade, conventional endometrioid morphology. High level microsatellite instability was observed in 71.4% (5/7) of LL cases. The majority of cases from both groups (LS: 85.7% [6/7]; LL: 87.5% [7/8]) were low-stage (T1a/T1b). Endometrial carcinoma was the presenting malignancy in 85.7% (6/7) of LS patients and 87.5% (7/8) of LL patients. Family history was suggestive of LS in 28.5% (2/7) of LS patients and 12.5% (1/8) of LL patients. Screening algorithms based on age and cancer history would have failed to identify LS patients in 57.1% (4/7) of cases. Although universal MMR-IHC identifies endometrial carcinoma patients with LS who would have been missed using targeted screening algorithms, it also identifies cancers with discordant IHC and germline results for which the somatic versus germline origin of the MMR defect is unclear. Further study of this LL group is required before drawing definitive conclusions about their familial cancer risk.
NASA Astrophysics Data System (ADS)
Gupta, Divya; Singh, Ajeet; Khan, Asad U.
2017-07-01
The universal problem of bacterial resistance to antibiotic reflects a serious threat for physicians to control infections. Evolution in bacteria results in the development of various complex resistance mechanisms to neutralize the bactericidal effect of antibiotics, like drug amelioration, target modification, membrane permeability reduction, and drug extrusion through efflux pumps. Efflux pumps acquire a wide range of substrate specificity and also the tremendous efficacy for drug molecule extrusion outside bacterial cells. Hindrance in the functioning of efflux pumps may rejuvenate the bactericidal effect of conventional antibiotics. Efflux pumps also play an important role in the exclusion or inclusion of quorum-sensing biomolecules responsible for biofilm formation in bacterial cells. This transit movement of quorum-sensing biomolecules inside or outside the bacterial cells may get interrupted by impeding the functioning of efflux pumps. Metallic nanoparticles represent a potential candidate to block efflux pumps of bacterial cells. The application of nanoparticles as efflux pump inhibitors will not only help to revive the bactericidal effect of conventional antibiotics but will also assist to reduce biofilm-forming capacity of microbes. This review focuses on a novel and fascinating application of metallic nanoparticles in synergy with conventional antibiotics for efflux pump inhibition.
The Women's Rights Convention at Seneca Falls: A Lesson Plan.
ERIC Educational Resources Information Center
OAH Magazine of History, 1988
1988-01-01
Uses the text of the Declaration of Sentiments, written at the 1848 women's rights convention in Seneca Falls, New York. Familiarizes students with key personalities and organizations in the women's movement and illustrates the significance of the history of women's rights. Provides discussion questions and related activities. (LS)
Breaking the diffraction limit of light-sheet fluorescence microscopy by RESOLFT
Hoyer, Patrick; de Medeiros, Gustavo; Balázs, Bálint; Norlin, Nils; Besir, Christina; Hanne, Janina; Kräusslich, Hans-Georg; Engelhardt, Johann; Sahl, Steffen J.; Hell, Stefan W.; Hufnagel, Lars
2016-01-01
We present a plane-scanning RESOLFT [reversible saturable/switchable optical (fluorescence) transitions] light-sheet (LS) nanoscope, which fundamentally overcomes the diffraction barrier in the axial direction via confinement of the fluorescent molecular state to a sheet of subdiffraction thickness around the focal plane. To this end, reversibly switchable fluorophores located right above and below the focal plane are transferred to a nonfluorescent state at each scanning step. LS-RESOLFT nanoscopy offers wide-field 3D imaging of living biological specimens with low light dose and axial resolution far beyond the diffraction barrier. We demonstrate optical sections that are thinner by 5–12-fold compared with their conventional diffraction-limited LS analogs. PMID:26984498
Outcome of Cardiac Rehabilitation Following Off-Pump Versus On-Pump Coronary Bypass Surgery
Arefizadeh, Reza; Hariri, Seyed Yaser; Moghadam, Adel Johari
2017-01-01
BACKGROUND: A few studies have compared the cardiac rehabilitation (CR) outcome between those who undergo conventional on-pump bypass surgery and off-pump surgery. We compared this outcome among the patients differentiated by the On-pump and off-pump surgical procedures about cardiovascular variables and psychological status. METHODS: This longitudinal study recruited 318 and 102 consecutive patients who had undergone CABG (on-pump surgery, n = 318 and off-pump surgery, n = 102) and been referred to the CR clinic. RESULTS: The off-pump surgery patients had more improvement in their metabolic equivalents (METs) value. The physical and mental components of health-related quality of life (QOL) (based on SF-36 questionnaire) as well as depression-anxiety (based on Costello-Comrey Depression and Anxiety Scale) were notably improved in the two study groups after the CR program, while changes in the QOL components scores and also depression-anxiety score were not different between the off-pump and on-pump techniques. CONCLUSIONS: Regarding QOL and psychological status, there were no differences in the CR outcome between those who underwent off-pump bypass surgery and those who underwent on-pump surgery; nevertheless, the off-pump technique was superior to the on-pump method on METs improvement following CR. PMID:28698744
NASA Astrophysics Data System (ADS)
Niedzielski, Tomasz; Kosek, Wiesław
2008-02-01
This article presents the application of a multivariate prediction technique for predicting universal time (UT1-UTC), length of day (LOD) and the axial component of atmospheric angular momentum (AAM χ 3). The multivariate predictions of LOD and UT1-UTC are generated by means of the combination of (1) least-squares (LS) extrapolation of models for annual, semiannual, 18.6-year, 9.3-year oscillations and for the linear trend, and (2) multivariate autoregressive (MAR) stochastic prediction of LS residuals (LS + MAR). The MAR technique enables the use of the AAM χ 3 time-series as the explanatory variable for the computation of LOD or UT1-UTC predictions. In order to evaluate the performance of this approach, two other prediction schemes are also applied: (1) LS extrapolation, (2) combination of LS extrapolation and univariate autoregressive (AR) prediction of LS residuals (LS + AR). The multivariate predictions of AAM χ 3 data, however, are computed as a combination of the extrapolation of the LS model for annual and semiannual oscillations and the LS + MAR. The AAM χ 3 predictions are also compared with LS extrapolation and LS + AR prediction. It is shown that the predictions of LOD and UT1-UTC based on LS + MAR taking into account the axial component of AAM are more accurate than the predictions of LOD and UT1-UTC based on LS extrapolation or on LS + AR. In particular, the UT1-UTC predictions based on LS + MAR during El Niño/La Niña events exhibit considerably smaller prediction errors than those calculated by means of LS or LS + AR. The AAM χ 3 time-series is predicted using LS + MAR with higher accuracy than applying LS extrapolation itself in the case of medium-term predictions (up to 100 days in the future). However, the predictions of AAM χ 3 reveal the best accuracy for LS + AR.
ATES/heat pump simulations performed with ATESSS code
NASA Astrophysics Data System (ADS)
Vail, L. W.
1989-01-01
Modifications to the Aquifer Thermal Energy Storage System Simulator (ATESSS) allow simulation of aquifer thermal energy storage (ATES)/heat pump systems. The heat pump algorithm requires a coefficient of performance (COP) relationship of the form: COP = COP sub base + alpha (T sub ref minus T sub base). Initial applications of the modified ATES code to synthetic building load data for two sizes of buildings in two U.S. cities showed insignificant performance advantage of a series ATES heat pump system over a conventional groundwater heat pump system. The addition of algorithms for a cooling tower and solar array improved performance slightly. Small values of alpha in the COP relationship are the principal reason for the limited improvement in system performance. Future studies at Pacific Northwest Laboratory (PNL) are planned to investigate methods to increase system performance using alternative system configurations and operations scenarios.
Revealing retroperitoneal liposarcoma morphology using optical coherence tomography
NASA Astrophysics Data System (ADS)
Carbajal, Esteban F.; Baranov, Stepan A.; Manne, Venu G. R.; Young, Eric D.; Lazar, Alexander J.; Lev, Dina C.; Pollock, Raphael E.; Larin, Kirill V.
2011-02-01
A new approach to distinguish normal fat, well-differentiated (WD), and dedifferentiated liposarcoma (LS) tumors is demonstrated, based on the use of optical coherence tomography (OCT). OCT images show the same structures seen with conventional histological methods. Our visual grading analysis is supported by numerical analysis of observed structures for normal fat and WDLS samples. Further development could apply the real-time and high resolution advantages of OCT for use in liposarcoma diagnosis and clinical procedures.
Performance Testing of a Prototypic Annular Linear Induction Pump for Fission Surface Power
NASA Technical Reports Server (NTRS)
Polzin, K. A.; Pearson, J. B.; Schoenfeld, M. P.; Webster, K.; Houts, M. G.; Godfroy, T. J.; Bossard, J. A.
2010-01-01
Results of performance testing of an annular linear induction pump are presented. The pump electromagnetically pumps liquid metal (NaK) through a circuit specially designed to allow for quantification of the performance. Testing was conducted over a range of conditions, including frequencies of 33, 36, 39, and 60 Hz, liquid metal temperatures from 25 to 525 C, and input voltages from 5 to 120 V. Pump performance spanned a range of flow rates from roughly 0.16 to 5.7 L/s (2.5 to 90 gpm), and pressure head <1 to 90 kPa (<0.145 to 13 psi). The maximum efficiency measured during testing was slightly greater than 6%. The efficiency was fairly insensitive to input frequency from 33 to 39 Hz, and was markedly lower at 60 Hz. In addition, the efficiency decreased as the NaK temperature was raised. While the pump was powered, the fluid responded immediately to changes in the input power level, but when power was removed altogether, there was a brief slow-down period before the fluid would come to rest. The performance of the pump operating on a variable frequency drive providing 60 Hz power compared favorably with the same pump operating on 60 Hz power drawn directly from the electrical grid.
Furukawa, Nobuyuki; Kuss, Oliver; Preindl, Konstantin; Renner, André; Aboud, Anas; Hakim-Meibodi, Kavous; Benzinger, Michael; Pühler, Thomas; Ensminger, Stephan; Fujita, Buntaro; Becker, Tobias; Gummert, Jan F; Börgermann, Jochen
2017-10-01
Meta-analyses from observational and randomized studies have demonstrated benefits of off-pump surgery for hard and surrogate endpoints. In some of them, increased re-revascularization was noted in the off-pump groups, which could impact their long-term survival. Therefore, we analyzed the course of all patients undergoing isolated coronary surgery regarding the major cardiac and cerebrovascular event (MACCE) criteria. A prospective register was taken from a high-volume off-pump center recording all anaortic off-pump (ANA), clampless off-pump (PAS-Port) and conventional (CONV) coronary artery bypass operations between July 2009 and June 2015. Propensity Score Matching was performed based on 28 preoperative risk variables. We identified 935 triplets (N = 2805). Compared with CONV, in-hospital mortality of both the ANA group (OR for ANA [95% CI] 0.25 [0.06; 0.83], P = 0.021), and the PAS-Port group was lower (OR for PAS-Port [95% CI] 0.50 [0.17; 1.32], P = 0.17). In the mid-term follow-up there were no significant differences between the groups regarding mortality (HR for ANA [95%-CI] 0.83 [0.55-1.26], P = 0.38; HR for PAS-Port [95%-CI] 1.06 [0.70-1.59], P = 0.79), incidence of stroke (HR for ANA 0.81 [0.43-1.53], P = 0.52; HR for PAS-Port 0.78 [0.41-1.50], P = 0.46), myocardial infarction (HR for ANA 0.53 [0.22-1.31], P = 0.17; HR for PAS-Port 0.78 [0.37-1.66], P = 0.52) or re-revascularization rate (HR for ANA 0.99 [0.67-1.44], P = 0.94; HR for PAS-Port 0.95 [0.65-1.38], P = 0.77). Both off-pump clampless techniques were associated with lower in-hospital mortality compared with conventional CABG. The mid-term course showed no difference with regard to the MACCE criteria between anaortic off-pump, clampless off-pump using PAS-Port and conventional CABG. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Cabanillas-Gonzalez, Juan; Grancini, Giulia; Lanzani, Guglielmo
2011-12-08
In this review we highlight the contribution of pump-probe spectroscopy to understand elementary processes taking place in organic based optoelectronic devices. The techniques described in this article span from conventional pump-probe spectroscopy to electromodulated pump-probe and the state-of-the-art confocal pump-probe microscopy. The article is structured according to three fundamental processes (optical gain, charge photogeneration and charge transport) and the contribution of these techniques on them. The combination of these tools opens up new perspectives for assessing the role of short-lived excited states on processes lying underneath organic device operation. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Exploring connectivity with large-scale Granger causality on resting-state functional MRI.
DSouza, Adora M; Abidin, Anas Z; Leistritz, Lutz; Wismüller, Axel
2017-08-01
Large-scale Granger causality (lsGC) is a recently developed, resting-state functional MRI (fMRI) connectivity analysis approach that estimates multivariate voxel-resolution connectivity. Unlike most commonly used multivariate approaches, which establish coarse-resolution connectivity by aggregating voxel time-series avoiding an underdetermined problem, lsGC estimates voxel-resolution, fine-grained connectivity by incorporating an embedded dimension reduction. We investigate application of lsGC on realistic fMRI simulations, modeling smoothing of neuronal activity by the hemodynamic response function and repetition time (TR), and empirical resting-state fMRI data. Subsequently, functional subnetworks are extracted from lsGC connectivity measures for both datasets and validated quantitatively. We also provide guidelines to select lsGC free parameters. Results indicate that lsGC reliably recovers underlying network structure with area under receiver operator characteristic curve (AUC) of 0.93 at TR=1.5s for a 10-min session of fMRI simulations. Furthermore, subnetworks of closely interacting modules are recovered from the aforementioned lsGC networks. Results on empirical resting-state fMRI data demonstrate recovery of visual and motor cortex in close agreement with spatial maps obtained from (i) visuo-motor fMRI stimulation task-sequence (Accuracy=0.76) and (ii) independent component analysis (ICA) of resting-state fMRI (Accuracy=0.86). Compared with conventional Granger causality approach (AUC=0.75), lsGC produces better network recovery on fMRI simulations. Furthermore, it cannot recover functional subnetworks from empirical fMRI data, since quantifying voxel-resolution connectivity is not possible as consequence of encountering an underdetermined problem. Functional network recovery from fMRI data suggests that lsGC gives useful insight into connectivity patterns from resting-state fMRI at a multivariate voxel-resolution. Copyright © 2017 Elsevier B.V. All rights reserved.
Extension of a GIS procedure for calculating the RUSLE equation LS factor
NASA Astrophysics Data System (ADS)
Zhang, Hongming; Yang, Qinke; Li, Rui; Liu, Qingrui; Moore, Demie; He, Peng; Ritsema, Coen J.; Geissen, Violette
2013-03-01
The Universal Soil Loss Equation (USLE) and revised USLE (RUSLE) are often used to estimate soil erosion at regional landscape scales, however a major limitation is the difficulty in extracting the LS factor. The geographic information system-based (GIS-based) methods which have been developed for estimating the LS factor for USLE and RUSLE also have limitations. The unit contributing area-based estimation method (UCA) converts slope length to unit contributing area for considering two-dimensional topography, however is not able to predict the different zones of soil erosion and deposition. The flowpath and cumulative cell length-based method (FCL) overcomes this disadvantage but does not consider channel networks and flow convergence in two-dimensional topography. The purpose of this research was to overcome these limitations and extend the FCL method through inclusion of channel networks and convergence flow. We developed LS-TOOL in Microsoft's.NET environment using C♯ with a user-friendly interface. Comparing the LS factor calculated with the three methodologies (UCA, FCL and LS-TOOL), LS-TOOL delivers encouraging results. In particular, LS-TOOL uses breaks in slope identified from the DEM to locate soil erosion and deposition zones, channel networks and convergence flow areas. Comparing slope length and LS factor values generated using LS-TOOL with manual methods, LS-TOOL corresponds more closely with the reality of the Xiannangou catchment than results using UCA or FCL. The LS-TOOL algorithm can automatically calculate slope length, slope steepness, L factor, S factor, and LS factors, providing the results as ASCII files which can be easily used in some GIS software. This study is an important step forward in conducting more accurate large area erosion evaluation.
Influence of kraft pulping on carboxylate content of softwood kraft pulps
Zheng Dang; Thomas Elder; Arthur J. Ragauskas
2006-01-01
This study characterizes changes in fiber charge, which is the carboxylate content of fibers, for two sets of kraft pulps: (1) conventional laboratory cooked loblolly pine kraft pulps and (2) conventional pulping (CK) versus low solids pulping (LS) pulps. Laboratory kraft pulping of loblolly pine was carried out to study the influence of pulping conditions, including...
NASA Astrophysics Data System (ADS)
Choi, M. K.; Morehouse, J. H.; Hughes, P. J.
1981-07-01
An analysis is performed of ground-coupled stand-alone and series configured solar-assisted liquid-to-air heat pump systems for residences. The year-round thermal performance of these systems for space heating, space cooling, and water heating is determined by simulation and compared against non-ground-coupled solar heat pump systems as well as conventional heating and cooling systems in three geographic locations: Washington, DC; Fort Worth, Texas; and Madison, Wisconsin. The results indicate that without tax credits a combined solar/ground-coupled heat pump system for space heating and cooling is not cost competitive with conventional systems. Its thermal performance is considerably better than non-ground-coupled solar heat pumps in Fort Worth. Though the ground-coupled stand-alone heat pump provides 51 percent of the heating and cooling load with non-purchased energy in Fort Worth, its thermal performance in Washington and Madison is poor.
Recent Advances in Source Localisation Using Range Measurements
2015-10-01
Range Weighted SR- LS ............................................................................................ 5 GEOLOCATION USING SEMIDEFINITE... LS ) and the squared range least squares (SR- LS ) [3]. The R- LS -based formulation is of great interest and has been known for its optimal performance...to efficiently compute an R- LS position estimate. A number of optimization tools may be applied to globally solve the R- LS problem and are usually
NASA Astrophysics Data System (ADS)
Rentian, Zhang; Honggeng, Zhu; Arnold, Jaap; Linbi, Yao
2010-06-01
Compared with vertical-installed pumps, the propeller (bulb tubular) pump systems can achieve higher hydraulic efficiencies, which are particularly suitable for low-head pumping stations. More than four propeller pumping stations are being, or will be built in the first stage of the S-to-N Water Diversion Project in China, diverting water from Yangtze River to the northern part of China to alleviate water-shortage problems and develop the economy. New structures of propeller pump have been developed for specified pumping stations in Jiangsu and Shandong Provinces respectively and Variable Frequency Drives (VFDs) are used in those pumping stations to regulate operating conditions. Based on the Navier-Stokes equations and the standard k-e turbulent model, numerical simulations of the flow field and performance prediction in the propeller pump system were conducted on the platform of commercial software CFX by using the SIMPLEC algorithm. Through optimal design of bulb dimensions and diffuser channel shape, the hydraulic system efficiency has improved evidently. Furthermore, the structures of propeller pumps have been optimized to for the introduction of conventional as well as permanent magnet motors. In order to improve the hydraulic efficiency of pumping systems, both the pump discharge and the motor diameter were optimized respectively. If a conventional motor is used, the diameter of the pump casing has to be increased to accommodate the motor installed inside. If using a permanent magnet motor, the diameter of motor casing can be decreased effectively without decreasing its output power, thus the cross-sectional area is enlarged and the velocity of flowing water decreased favorably to reduce hydraulic loss of discharge channel and thereby raising the pumping system efficiency. Witness model tests were conducted after numerical optimization on specific propeller pump systems, indicating that the model system hydraulic efficiencies can be improved by 0.5%˜3.7% in different specified operational conditions.
Synthesis and P-glycoprotein induction activity of colupulone analogs.
Bharate, Jaideep B; Batarseh, Yazan S; Wani, Abubakar; Sharma, Sadhana; Vishwakarma, Ram A; Kaddoumi, Amal; Kumar, Ajay; Bharate, Sandip B
2015-05-21
Brain amyloid-beta (Aβ) plaques are one of the primary hallmarks associated with Alzheimer's disease (AD) pathology. Efflux pump proteins located at the blood-brain barrier (BBB) have been reported to play an important role in the clearance of brain Aβ, among which the P-glycoprotein (P-gp) efflux transporter pump has been shown to play a crucial role. Thus, P-gp has been considered as a potential therapeutic target for treatment of AD. Colupulone, a prenylated phloroglucinol isolated from Humulus lupulus, is known to activate pregnane-X-receptor (PXR), which is a nuclear receptor controlling P-gp expression. In the present work, we aimed to synthesize and identify analogs of colupulone that are potent P-gp inducer(s) with an ability to enhance Aβ transport across the BBB. A series of colupulone analogs were synthesized by modifications at both prenyl as well as acyl domains. All compounds were screened for P-gp induction activity using a rhodamine 123 based efflux assay in the P-gp overexpressing human adenocarcinoma LS-180 cells, wherein all compounds showed significant P-gp induction activity at 5 μM. In the western blot studies in LS-180 cells, compounds 3k and 5f were able to induce P-gp as well as LRP1 at 1 μM. The effect of compounds on the Aβ uptake and transport was then evaluated. Among all tested compounds, diprenylated acyl phloroglucinol displayed a significant increase (29%) in Aβ transport across bEnd3 cells grown on inserts as a BBB model. The results presented here suggest the potential of this scaffold to enhance clearance of brain Aβ across the BBB and thus its promise for development as a potential anti-Alzheimer agent.
Topological photonic orbital-angular-momentum switch
NASA Astrophysics Data System (ADS)
Luo, Xi-Wang; Zhang, Chuanwei; Guo, Guang-Can; Zhou, Zheng-Wei
2018-04-01
The large number of available orbital-angular-momentum (OAM) states of photons provides a unique resource for many important applications in quantum information and optical communications. However, conventional OAM switching devices usually rely on precise parameter control and are limited by slow switching rate and low efficiency. Here we propose a robust, fast, and efficient photonic OAM switch device based on a topological process, where photons are adiabatically pumped to a target OAM state on demand. Such topological OAM pumping can be realized through manipulating photons in a few degenerate main cavities and involves only a limited number of optical elements. A large change of OAM at ˜10q can be realized with only q degenerate main cavities and at most 5 q pumping cycles. The topological photonic OAM switch may become a powerful device for broad applications in many different fields and motivate a topological design of conventional optical devices.
Squeezed light from conventionally pumped multi-level lasers
NASA Technical Reports Server (NTRS)
Ralph, T. C.; Savage, C. M.
1992-01-01
We have calculated the amplitude squeezing in the output of several conventionally pumped multi-level lasers. We present results which show that standard laser models can produce significantly squeezed outputs in certain parameter ranges.
Haidar, Ahmad; Legault, Laurent; Messier, Virginie; Mitre, Tina Maria; Leroux, Catherine; Rabasa-Lhoret, Rémi
2015-01-01
The artificial pancreas is an emerging technology for the treatment of type 1 diabetes and two configurations have been proposed: single-hormone (insulin alone) and dual-hormone (insulin and glucagon). We aimed to delineate the usefulness of glucagon in the artificial pancreas system. We did a randomised crossover trial of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy (continuous subcutaneous insulin infusion) in participants aged 12 years or older with type 1 diabetes. Participants were assigned in a 1:1:1:1:1:1 ratio with blocked randomisation to the three interventions and attended a research facility for three 24-h study visits. During visits when the patient used the single-hormone artificial pancreas, insulin was delivered based on glucose sensor readings and a predictive dosing algorithm. During dual-hormone artificial pancreas visits, glucagon was also delivered during low or falling glucose. During conventional insulin pump therapy visits, patients received continuous subcutaneous insulin infusion. The study was not masked. The primary outcome was the time for which plasma glucose concentrations were in the target range (4·0-10·0 mmol/L for 2 h postprandially and 4·0-8·0 mmol/L otherwise). Hypoglycaemic events were defined as plasma glucose concentration of less than 3·3 mmol/L with symptoms or less than 3·0 mmol/L irrespective of symptoms. Analysis was by modified intention to treat, in which we included data for all patients who completed at least two visits. A p value of less than 0·0167 (0·05/3) was regarded as significant. This trial is registered with ClinicalTrials.gov, number NCT01754337. The mean proportion of time spent in the plasma glucose target range over 24 h was 62% (SD 18), 63% (18), and 51% (19) with single-hormone artificial pancreas, dual-hormone artificial pancreas, and conventional insulin pump therapy, respectively. The mean difference in time spent in the target range between single-hormone artificial pancreas and conventional insulin pump therapy was 11% (17; p=0·002) and between dual-hormone artificial pancreas and conventional insulin pump therapy was 12% (21; p=0·00011). There was no difference (15; p=0·75) in the proportion of time spent in the target range between the single-hormone and dual-hormone artificial pancreas systems. There were 52 hypoglycaemic events with conventional insulin pump therapy (12 of which were symptomatic), 13 with the single-hormone artificial pancreas (five of which were symptomatic), and nine with the dual-hormone artificial pancreas (0 of which were symptomatic); the number of nocturnal hypoglycaemic events was 13 (0 symptomatic), 0, and 0, respectively. Single-hormone and dual-hormone artificial pancreas systems both provided better glycaemic control than did conventional insulin pump therapy. The single-hormone artificial pancreas might be sufficient for hypoglycaemia-free overnight glycaemic control. Canadian Diabetes Association; Fondation J A De Sève; Juvenile Diabetes Research Foundation; and Medtronic. Copyright © 2015 Elsevier Ltd. All rights reserved.
Newberry Volcano EGS Demonstration: Plans and Results
NASA Astrophysics Data System (ADS)
Cladouhos, T. T.; Petty, S.; Moore, M.; Nordin, Y.; De Rocher, T.; Callahan, O.; Perry, D.
2012-12-01
Engineered or Enhanced Geothermal Systems (EGS) have the potential to expand the availability of clean renewable, baseload energy beyond conventional geothermal areas. An EGS reservoir is created by injecting large volumes of cold water into hot, low-permeability rock to induce seismic slip and enhance the permeability of pre-existing fractures. To date, EGS demonstrations have been limited to a single stimulation per well and sub-economic production rates because a method to isolate the first fracture in a hot well has been lacking. In addition, some recent EGS demonstrations have been negatively impacted by induced seismicity felt by area residents. The Newberry Volcano Enhanced Geothermal System (EGS) Demonstration in central Oregon, funded in part by DOE Grant DE-EE0002777, is now in the field operations phase after two years of planning. The stimulation well, NWG 55-29 drilled in 2008, has very little natural permeability but is very hot, with a bottom hole temperature over 300°C. The Demonstration will test recent technological advances designed to reduce the cost of power generated by EGS and the risk of felt seismicity. First, the stimulation pumps used were designed to run for weeks with little downtime and deliver large volumes of water (1000 gpm, 63 l/s) at relatively low well-head pressure (max. 3000 psi, 20 MPa). This pump specification is based on the rock mechanics-based model of hydroshearing, reduction of effective normal stress and friction on existing fractures, which promotes shear slip and enhances permeability. In contrast, pumps used in hydrofracking, creation of permeability through tensile failure of the rock, operate for shorter periods at much lower volumes and higher pressures. Second, multiple zone stimulation in the open-hole sections of EGS wells would significantly reduce the cost of EGS power production by increasing the productivity of each well. To facilitate multiple zone stimulation, AltaRock Energy has developed a suite of thermo-degradable zonal isolation materials (TZIMs) to temporarily seal off fractures in a geothermal well, allowing for stimulation of secondary and tertiary fracture zones, thus optimizing the injection/production profile of the entire well. TZIMs with ranges of thermal degradation properties have been extensively tested in the lab and two conventional geothermal fields. At Newberry, TZIMs that are stable at 200°C and degrade quickly at 300°C will be used. Third, the project follows a project-specific Induced Seismicity Mitigation Plan (ISMP) to evaluate, monitor for, and mitigate felt induced seismicity. During stimulation, 16 seismic stations, installed within 4 km of the target stimulation zone, monitor microseismicity and growth of the EGS reservoir. Seismicity occurring in undesirable locations or with ground accelerations or magnitudes above agreed thresholds, would result in operational changes to prevent unwanted seismicity, such as the use of TZIMs or lower well head pressures. Results of the Demonstration, shared with the public, geothermal and scientific communities include the real-time microseismicity, injection pressures and flow rates, and final injectivity of the stimulated well.
Piezoelectric Properties of LiSbO3-Modified (K0.48Na0.52)NbO3 Lead-Free Ceramics
NASA Astrophysics Data System (ADS)
Wu, Jiagang; Wang, Yuanyu; Xiao, Dingquan; Zhu, Jianguo; Yu, Ping; Wu, Lang; Wu, Wenjuan
2007-11-01
Lead-free piezoelectric (1-x)(K0.48Na0.52)NbO3-xLiSbO3 [(1-x)KNN-xLS] ceramics were prepared by conventional sintering. A morphotropic phase boundary (MPB) between the orthorhombic and tetragonal phases was identified in the composition range of 0.04
Development of a Compact Efficient Cooling Pump for Space Suit Life Support Systems
NASA Technical Reports Server (NTRS)
vanBoeyen, Roger W.; Reeh, Jonathan A.; Trevino, Luis
2008-01-01
With the increasing demands placed on extravehicular activity (EVA) for the International Space Station (ISS) assembly and maintenance, along with planned lunar and Martian missions, the need for increased human productivity and capability becomes ever more critical. This is most readily achieved by reduction in space suit weight and volume, and increased hardware reliability, durability, and operating lifetime. Considerable progress has been made with each successive generation of space suit design; from the Apollo A7L suit, to the current Shuttle Extravehicular Mobile Unit (EMU) suit, and the next generation Constellation Space Suit Element (CSSE). However, one area of space suit design which has continued to lag is the fluid pump used to drive the water cooling loop of the Primary Life Support System (PLSS). The two main types of fluid pumps typically used in space applications are rotodynamic pumps (pumping is achieved through a rotary vaned impeller) and displacement pumps (which includes rotary and diaphragm pumps). The rotating and moving parts found in the pumps and electric motor add significantly to the susceptibility to wear and friction, thermal mismatch, and complexity of the pumps. Electric motor-driven pumps capable of achieving high operational reliability are necessarily large, heavy, and energy inefficient. This report describes a development effort conducted for NASA by Lynntech, Inc., who recently demonstrated the feasibility of an electrochemically-driven fluid cooling pump. With no electric motor and minimal lightweight components, an electrochemically-driven pump is expected to be significantly smaller, lighter and achieve a longer life time than conventional rotodynamic and displacement pumps. By employing sulfonated polystyrene-based proton exchange membranes, rather than conventional Nafion membranes, a significant reduction in the actuator power consumption was demonstrated. It was also demonstrated that these membranes possess the necessary mechanical strength, durability, and temperature range for long life space operation. The preliminary design for a Phase II prototype pump compares very favorably to the fluid cooling pumps currently used in space suit portable life support systems (PLSS). Characteristics of the electrochemically-driven pump are described and the benefits of the technology as a replacement for electric motor pumps in mechanically pumped single-phase fluid loops (MPFLs) is discussed.
NASA Astrophysics Data System (ADS)
Congdon, R. D.
2012-12-01
There is frequently a need in land management agencies for a quick and easy method for estimating hydrogeologic conditions in a watershed for which there is very little subsurface information. Setting up a finite difference or finite element model takes valuable time that often is not available when decisions need to be made quickly. An analytic element model (AEM), GFLOW in this case, may enable the investigator to produce a preliminary steady-state model for a watershed, and to easily evaluate variants of the conceptual model. Use of preexisting data, such as stream gage data or USGS reports makes the job much easier. Solutions to analytic element models are obtained within seconds. The Eagle Creek watershed in central New Mexico is a site of local water supply issues in an area of volcanic and plutonic rocks. Parameters estimated by groundwater consultants and the USGS, and discharge data from three USGS stream gages were used to set up the steady-state analytical model (GFLOW). Matching gage records with line-sink fluxes facilitated conceptualization of local groundwater flow and quick analysis of the effects of steady water supply pumping on Eagle Creek. Because of steep topgraphy and limited access, a water supply well is located within the stream channel within 20 meters of the creek, and it would be useful to evaluate the effects of the well on stream flow. A USGS report (SIR 2010-5205) revealed a section of Eagle Creek with a high vertical conductivity which results in flow loss of up to 34 l/s (including flow to the water table and flow into alluvium) when the well was pumped and the water table was lowered below the channel bottom. The water supply well was simulated with a steady-state well pumping at the average and maximum rates of 12 l/s and 31 l/s. The initial simulation shows that pumping at these rates results in stream flow loss of 19% and 51%, respectively. The simulation was conducted with average flow conditions, and this information will be important in planning for management during periods of drought, as well as times of more normal precipitation; as water uses must be balanced with the needs of the existing ecosystem. Alternatives, such as low conductivity blocks between stream channels and different volumetric and geographic pumping scenarios may also be readily explored in an AEM. Exporting these scenarios into MODFLOW simulations will enable us to evaluate transient and cyclical pumping effects on the surface waters for each AEM conceptualization, as well as being able to simulate seasonal recharge. However, in many cases the use of MODFLOW may not be necessary, if the AEM proves sufficient to answer the relevant questions. Symbiotic use of GFLOW and MODFLOW will be an invaluable aid in evaluating groundwater and its uses in National Forest watersheds, especially in cases when time is a critical factor in informed decision-making.
Navarro, Marta; Benito, Javier; Paseta, Lorena; Gascón, Ignacio; Coronas, Joaquín; Téllez, Carlos
2018-01-10
An innovative procedure for positioning a monolayer of hydrophilic metal organic framework (MOF) MIL-101(Cr) (MIL, Materials of Institute Lavoisier) nanoparticles (NPs) in thin-film nanocomposite (TFN) membranes has been implemented by transferring a Langmuir-Schaefer (LS) film of the MOF in between the polyamide thin layer at the top and the cross-linked asymmetric polyimide (P84) support at the bottom. The presence and layout of the LS-MIL-101(Cr) monolayer in the TFN membrane was confirmed by scanning transmission electron microscopy imaging with a high-angle annular dark-field detector images and X-ray photoelectron spectroscopy, energy-dispersive X-ray spectroscopy, electron energy loss spectroscopy, and atomic force microscopy analyses. This methodology requires the smallest amount of MOF reported to date, 3.8 μg cm -2 , and promotes the formation of a defect-free ultrathin MOF film. Although conventional TFN membranes tend to show MOF agglomerates that could contribute to the formation of unselective defects, LS-TFN membranes, characterized by a homogeneous and continuous MOF coating, exhibit an optimal membrane performance, without a significant decrease in selectivity. Outstanding methanol permeances, one of the best results reported to date, of 10.1 ± 0.5 L m -2 h -1 bar -1 when filtering sunset yellow and of 9.5 ± 2.1 L m -2 h -1 bar -1 when filtering rose bengal have been achieved in LS-TFN membranes with a rejection higher than 90% in all cases. Methanol permeates through the polyamide and the LS-MIL-101(Cr) monolayer, greatly enhanced by the MOF pore system, in comparison to thin-film composite and conventional TFN membranes (7.5 ± 0.7 and 7.7 ± 1.1 L m -2 h -1 bar -1 when filtering sunset yellow), respectively, in which polyamide areas free of MOF NPs are present.
Any link between sexual inactivity and treadle pump performance characteristics: The Malawi case
NASA Astrophysics Data System (ADS)
Joseph, Chidanti-Malunga; Yamikani, Malunga
In mitigating the effects of climate change in Malawi, government promotes the use of low cost irrigation technologies to small-scale farmers, especially in wetlands where water is available. The treadle pump is one such technology. The pump is a manual water lifting device operated by feet. Although the technology has been widely accepted by small-scale farmers, there are documented reports that some farmers abandon the technology, preferring other technologies such as river diversion. One theory for the abandonment is that female farmers claim that the technology makes their male counterparts sexually inactive. This research seeks to find an explanation to the misconception. The study analyzed the physical characteristics of the treadle pump and its users. The results show that the technology is male-dominated (30% were females out of a sample of 40). The results also show that the technology is labor-intensive with very small discharge rates (an average of 0.78 l/s) achieved regardless of the BMI of the operator. With such small discharge rates, in order to fulfill irrigation requirements of a crop, the operator has to pump for long hours. This exercise makes men naturally tired, perhaps making them sexually inactive as well.
Miniature Scroll Pumps Fabricated by LIGA
NASA Technical Reports Server (NTRS)
Wiberg, Dean; Shcheglov, Kirill; White, Victor; Bae, Sam
2009-01-01
Miniature scroll pumps have been proposed as roughing pumps (low - vacuum pumps) for miniature scientific instruments (e.g., portable mass spectrometers and gas analyzers) that depend on vacuum. The larger scroll pumps used as roughing pumps in some older vacuum systems are fabricated by conventional machining. Typically, such an older scroll pump includes (1) an electric motor with an eccentric shaft to generate orbital motion of a scroll and (2) conventional bearings to restrict the orbital motion to a circle. The proposed miniature scroll pumps would differ from the prior, larger ones in both design and fabrication. A miniature scroll pump would include two scrolls: one mounted on a stationary baseplate and one on a flexure stage (see figure). An electromagnetic actuator in the form of two pairs of voice coils in a push-pull configuration would make the flexure stage move in the desired circular orbit. The capacitance between the scrolls would be monitored to provide position (gap) feedback to a control system that would adjust the drive signals applied to the voice coils to maintain the circular orbit as needed for precise sealing of the scrolls. To minimize power consumption and maximize precision of control, the flexure stage would be driven at the frequency of its mechanical resonance. The miniaturization of these pumps would entail both operational and manufacturing tolerances of <1 m. Such tight tolerances cannot be achieved easily by conventional machining of high-aspect-ratio structures like those of scroll-pump components. In addition, the vibrations of conventional motors and ball bearings exceed these tight tolerances by an order of magnitude. Therefore, the proposed pumps would be fabricated by the microfabrication method known by the German acronym LIGA ( lithographie, galvanoformung, abformung, which means lithography, electroforming, molding) because LIGA has been shown to be capable of providing the required tolerances at large aspect ratios.
Rentfrow, G; Sauber, T E; Allee, G L; Berg, E P
2003-08-01
The objectives of this study were to evaluate diets possessing different fatty acid profiles (as influenced by corn type) with regard to fatty acid profile and firmness of pork bellies. Crossbred barrows (n=196) were fed one of four corn-based diets consisting of conventional corn (CONV), CONV with choice white grease (CWG), high oil corn (HOC), or high oleic, high oil corn (HOHOC). Following 98 days on test, two animals representing the average pen weight (118 kg) were selected for harvest (n=56). A 50-g fat sample was removed from each belly for fatty acid profile analysis. Lateral and vertical flex tests were performed to determine belly firmness. Bellies were pumped and cooked according to a commercial protocol. Total saturated fatty acids increased (P<0.001) and total unsaturated fatty acids decreased (P<0.05) when CWG was added to the CONV diet or when HOC or HOHOC were substituted for CONV corn. Pigs fed CONV corn had firmer bellies, while those fed HOC were softer. No differences were observed across treatment for percentage pump retention, smokehouse yield, or slicing yield (P>0.05). Based on the results of this study, corn type influences fatty acid profile, and belly firmness, but does not affect pump retention, or slicing yields.
Fracture resistance of a selection of full-contour all-ceramic crowns: an in vitro study.
Zesewitz, Tim F; Knauber, Andreas W; Nothdurft, Frank P
2014-01-01
This study aimed to evaluate the fracture resistance of monolithic single crowns made from zirconia (ZI), lithium disilicate (LS2), or feldspar ceramic (FC). Five groups of crowns representing a maxillary first molar were made with the appropriate dimensions according to the manufacturer's instructions. The ZI and LS2 crowns were luted adhesively or cemented conventionally on a metal abutment tooth analog. The feldspar ceramic crowns were luted adhesively. All specimens underwent axial loading until fracture. The crowns in the ZI groups possessed the highest fracture resistance independent of the mode of fixation.
Analysis of geothermal temperatures for heat pumps application in Paraná (Brasil)
NASA Astrophysics Data System (ADS)
Santos, Alexandre F.; de Souza, Heraldo J. L.; Cantao, Mauricio P.; Gaspar, Pedro D.
2016-11-01
Geothermal heat pumps are broadly used in developed countries but scarcely in Brazil, in part because there is a lack of Brazilian soil temperature data. The aims of this work are: to present soil temperature measurements and to compare geothermal heat pump system performances with conventional air conditioning systems. Geothermal temperature measurement results are shown for ten Paraná State cities, representing different soil and climate conditions. The measurements were made yearlong with calibrated equipment and digital data acquisition system in different measuring stations. Geothermal and ambient temperature data were used for simulations of the coeficient of performance (COP), by means of a working fluid pressure-enthalpy diagram based software for vapor-compression cycle. It was verified that geothermal temperature measured between January 13 to October 13, 2013, varied from 16 to 24 °C, while room temperature has varied between 2 and 35 °C. Average COP values for conventional system were 3.7 (cooling mode) and 5.0 kW/kW (heating mode), corresponding to 5.9 and 7.9 kW/kW for geothermal system. Hence it was verified an average eficiency gain of 59%with geothermal system utilization in comparison with conventional system.
Ultra-high speed vacuum pump system with first stage turbofan and second stage turbomolecular pump
Jostlein, Hans
2006-04-04
An ultra-high speed vacuum pump evacuation system includes a first stage ultra-high speed turbofan and a second stage conventional turbomolecular pump. The turbofan is either connected in series to a chamber to be evacuated, or is optionally disposed entirely within the chamber. The turbofan employs large diameter rotor blades operating at high linear blade velocity to impart an ultra-high pumping speed to a fluid. The second stage turbomolecular pump is fluidly connected downstream from the first stage turbofan. In operation, the first stage turbofan operates in a pre-existing vacuum, with the fluid asserting only small axial forces upon the rotor blades. The turbofan imparts a velocity to fluid particles towards an outlet at a high volume rate, but moderate compression ratio. The second stage conventional turbomolecular pump then compresses the fluid to pressures for evacuation by a roughing pump.
Geothermal Heat Pump Basics | NREL
a free source of hot water. Geothermal heat pumps use much less energy than conventional heating resources: Geothermal Heat Pumps U.S. Department of Energy's Office of Energy Efficiency and Renewable Heat Pump Basics Geothermal Heat Pump Basics Geothermal heat pumps take advantage of the nearly
Low-temperature thermal control for a lunar base
NASA Technical Reports Server (NTRS)
Swanson, Theodore D.; Radermacher, Reinhard; Costello, Frederick A.; Moore, James S., Jr.; Mengers, David R.
1990-01-01
The generic problem of rejecting low- to moderate-temperature heat from space facilities located in a hot thermal sink environment is studied, and the example of a lunar base located near the equator is described. The effective thermal sink temperature is often above or near nominal room temperature. A three heat pump assisted thermal bus concept appears to be the most viable as they are the least sensitive to environmental conditions. Weight estimates are also developed for each of the five thermal control concepts studied: (1) 149kg/kW for a central thermal loop with unitary heat pumps; (2) 133 kg/kW for a conventional bus connected to large, central heat pumps at the radiator; (3) 134 kg/kW for a central, dual loop heat pump concept; (4) 95 kg/kW for the selective field-of-view radiator; and (5) 126 kg/kW for the regolith concept.
An Alternating Current Electroosmotic Pump Based on Conical Nanopore Membranes.
Wu, Xiaojian; Ramiah Rajasekaran, Pradeep; Martin, Charles R
2016-04-26
Electroosmotic flow (EOF) is used to pump solutions through microfluidic devices and capillary electrophoresis columns. We describe here an EOF pump based on membrane EOF rectification, an electrokinetic phenomenon we recently described. EOF rectification requires membranes with asymmetrically shaped pores, and conical pores in a polymeric membrane were used here. We show here that solution flow through the membrane can be achieved by applying a symmetrical sinusoidal voltage waveform across the membrane. This is possible because the alternating current (AC) carried by ions through the pore is rectified, and we previously showed that rectified currents yield EOF rectification. We have investigated the effect of both the magnitude and frequency of the voltage waveform on flow rate through the membrane, and we have measured the maximum operating pressure. Finally, we show that operating in AC mode offers potential advantages relative to conventional DC-mode EOF pumps.
Off-pump coronary bypass surgery adversely affects alveolar gas exchange.
Gasparović, Hrvoje; Unić, Daniel; Sutlić, Zeljko; Husedzinović, Ino; Biocina, Bojan; Rudez, Igor; Nikić, Nada; Jelić, Ivan
2008-03-01
While the introduction of off-pump myocardial revascularization (OPCAB) has initially shown promise in reducing respiratory complications inherent to conventional coronary surgery, it has failed to eradicate them. Our study focused on quantifying the lactate release from the lungs and the dysfunction at the level of the alveolar-capillary membrane precipitated by OPCAB at different time points after the insult. Furthermore, we aimed to determine the impact of pulmonary lactate production on systemic lactic acid concentrations. The study was conducted in a prospective observational fashion. Forty consecutive patients undergoing OPCAB were analyzed. The mean patient age was 60 +/- 10 years. The mean EUROScore was 3.8 +/- 2.9. The alveolar-arterial O2 gradient increased from 19 [range 9 to 30] to 26 [range 20 to 34] kPa (P < 0.001) and remained elevated up to 6 hours after surgery. It rapidly declined again by 18 hours postoperatively. The observed increase in the pulmonary lactate release (PLR) from a baseline value of 0.022 [range -0.074 to 0.066] to 0.089 [range 0.016 to 0.209] mmol/min/m2 at six hours postoperatively did not reach statistical significance (P = 0.105). The systemic arterial lactate (Ls) concentration increased from 0.94 [range 0.78 to 1.06] to 1.39 [range 0.97 to 2.81] mmol/L (P < 0.001). The venoarterial pCO2 difference showed no significant change in comparison to baseline values. The mortality in the studied group was 2.5% (1/40). The pulmonary lactate production showed a statistically significant correlation with the systemic lactate concentration (R = 0.46; P = 0.003). Pulmonary injury following off pump myocardial revascularization was evidenced by a prompt increase in the alveolar-arterial oxygen gradient. The alveolar-arterial O2 gradient correlated with the duration of mechanical ventilation.
León-Vargas, Fabian; Calm, Remei; Bondia, Jorge; Vehí, Josep
2012-01-01
Objective Set-inversion-based prandial insulin delivery is a new model-based bolus advisor for postprandial glucose control in type 1 diabetes mellitus (T1DM). It automatically coordinates the values of basal–bolus insulin to be infused during the postprandial period so as to achieve some predefined control objectives. However, the method requires an excessive computation time to compute the solution set of feasible insulin profiles, which impedes its integration into an insulin pump. In this work, a new algorithm is presented, which reduces computation time significantly and enables the integration of this new bolus advisor into current processing features of smart insulin pumps. Methods A new strategy was implemented that focused on finding the combined basal–bolus solution of interest rather than an extensive search of the feasible set of solutions. Analysis of interval simulations, inclusion of physiological assumptions, and search domain contractions were used. Data from six real patients with T1DM were used to compare the performance between the optimized and the conventional computations. Results In all cases, the optimized version yielded the basal–bolus combination recommended by the conventional method and in only 0.032% of the computation time. Simulations show that the mean number of iterations for the optimized computation requires approximately 3.59 s at 20 MHz processing power, in line with current features of smart pumps. Conclusions A computationally efficient method for basal–bolus coordination in postprandial glucose control has been presented and tested. The results indicate that an embedded algorithm within smart insulin pumps is now feasible. Nonetheless, we acknowledge that a clinical trial will be needed in order to justify this claim. PMID:23294789
ERIC Educational Resources Information Center
Huang, Rongjin; Gong, Zikun; Han, Xue
2016-01-01
Lesson study (LS) has been practiced in China as an effective way to advance teachers' professional development for decades. This study explores how LS improves teaching that promotes students' understanding. A LS group including didacticians (practice-based teaching research specialist and University-based mathematics educators) and mathematics…
Blanco, Marco A.; Sahin, Erinc; Li, Yi; Roberts, Christopher J.
2011-01-01
The classic analysis of Rayleigh light scattering (LS) is re-examined for multi-component protein solutions, within the context of Kirkwood-Buff (KB) theory as well as a more generalized canonical treatment. Significant differences arise when traditional treatments that approximate constant pressure and neglect concentration fluctuations in one or more (co)solvent∕co-solute species are compared with more rigorous treatments at constant volume and with all species free to fluctuate. For dilute solutions, it is shown that LS can be used to rigorously and unambiguously obtain values for the osmotic second virial coefficient (B22), in contrast with recent arguments regarding protein interactions deduced from LS experiments. For more concentrated solutions, it is shown that conventional analysis over(under)-estimates the magnitude of B22 for significantly repulsive(attractive) conditions, and that protein-protein KB integrals (G22) are the more relevant quantity obtainable from LS. Published data for α–chymotrypsinogen A and a series of monoclonal antibodies at different pH and salt concentrations are re-analyzed using traditional and new treatments. The results illustrate that while traditional analysis may be sufficient if one is interested in only the sign of B22 or G22, the quantitative values can be significantly in error. A simple approach is illustrated for determining whether protein concentration (c2) is sufficiently dilute for B22 to apply, and for correcting B22 values from traditional LS regression at higher c2 values. The apparent molecular weight M2, app obtained from LS is shown to generally not be equal to the true molecular weight, with the differences arising from a combination of protein-solute and protein-cosolute interactions that may, in principle, also be determined from LS. PMID:21682538
Nakauchi, Masaya; Suda, Koichi; Nakamura, Kenichi; Shibasaki, Susumu; Kikuchi, Kenji; Nakamura, Tetsuya; Kadoya, Shinichi; Ishida, Yoshinori; Inaba, Kazuki; Taniguchi, Keizo; Uyama, Ichiro
2017-11-01
Higher morbidity in total gastrectomy than in distal gastrectomy has been reported, but laparoscopic subtotal gastrectomy (LsTG) has been reported to be safe and feasible in early gastric cancer (GC). We determined the surgical, nutritional and oncological outcomes of LsTG for advanced gastric cancer (AGC). Of the 816 consecutive patients with GC who underwent radical gastrectomy at our institution between 2008 and 2012, 253 who underwent curative laparoscopic gastrectomy (LG) for AGC were enrolled. LsTG was indicated for patients with upper stomach third tumors, who hoped to avoid total gastrectomy, <4 cm to the esophagogastric junction and a 2-cm proximal margin with cut end negative in frozen section, whereas laparoscopic conventional distal gastrectomy (LcDG) and laparoscopic total gastrectomy (LTG) were performed otherwise. Surgical outcomes and postoperative nutritional status were primarily assessed. Of 253 patients, the morbidity (Clavien-Dindo classification grade ≥ III) was 17.0% (43 patients). The 3-year overall survival and 3-year recurrence-free survival rates were 80.2 and 73.5%, respectively. LcDG, LsTG and LTG were performed in 121, 27 and 105 patients, individually. Morbidity was strongly associated with LTG (P = 0.001). Postoperative loss of body weight was significantly greater after LTG in comparison with LcDG or LsTG (P < 0.001). No difference in morbidity and postoperative loss of body weight were observed between LcDG and LsTG group. LG for AGC was feasible and safe surgically and oncologically. LsTG for AGC may be safer than LTG from surgical and postoperative nutritional point of view.
Characterization and Modeling of a Water-based Liquid Scintillator
L. J. Bignell; Beznosko, D.; Diwan, M. V.; ...
2015-12-15
We characterised Water-based Liquid Scintillator (WbLS) using low energy protons, UV-VIS absorbance, and fluorescence spectroscopy. We have also developed and validated a simulation model that describes the behaviour of WbLS in our detector configurations for proton beam energies of 210 MeV, 475 MeV, and 2 GeV and for two WbLS compositions. These results have enabled us to estimate the light yield and ionisation quenching of WbLS, as well as to understand the influence of the wavelength shifting of Cherenkov light on our measurements. These results are relevant to the suitability of WbLS materials for next generation intensity frontier experiments.
Shade, Brandon C; Schiavo, Kellie; Rosenthal, Tami; Connelly, James T; Melchior, Richard W
2016-06-05
Recent advances in blood pump technology have led to an increased use of centrifugal pumps for prolonged extracorporeal membrane oxygenation (ECMO). Data from the Extracorporeal Life Support Organization confirms that many institutions have converted to centrifugal pumps after prior experience with roller pump technology. Centrifugal pump technology is more compact and may generate less heat and hemolysis than a conventional roller pump. Based on the potential advantages of centrifugal pumps, a decision was made institution-wide to convert to centrifugal pump technology in pediatric implementation of ECMO. Based on limited prior experience with centrifugal pumps, a multidisciplinary approach was used to implement this new technology. The new centrifugal pump (Sorin Revolution, Arvada, CO) was intended for ECMO support in the cardiac intensive care unit (CICU), the pediatric intensive care unit (PICU) and the neonatal intensive care unit (NICU). The perfusion team used their knowledge and expertise with centrifugal pumps to create the necessary teaching tools and interactive training sessions for the technical specialists who consisted primarily of registered nurses and respiratory therapists. The first phase consisted of educating all personnel involved in the care of the ECMO patient, followed by patient implementation in the CICU, followed by the PICU and NICU. The institution-wide conversion took several months to complete and was well received among all disciplines in the CICU and PICU. The NICU personnel did use the centrifugal pump circuit, but decided to revert back to using the roller pump technology. A systematic transition from roller pump to centrifugal pump technology with a multidisciplinary team can ensure a safe and successful implementation. © The Author(s) 2016.
Seeking a valid gold standard for an innovative, dialect-neutral language test.
Pearson, Barbara Zurer; Jackson, Janice E; Wu, Haotian
2014-04-01
PURPOSE In this study, the authors explored alternative gold standards to validate an innovative, dialect-neutral language assessment. METHOD Participants were 78 African American children, ages 5;0 (years;months) to 6;11. Twenty participants had previously been identified as having language impairment. The Diagnostic Evaluation of Language Variation-Norm Referenced (DELV-NR; Seymour, Roeper, & J. de Villiers, 2005) was administered, and concurrent language samples (LSs) were collected. Using LS profiles as the gold standard, sensitivity, specificity, and other measures of diagnostic accuracy were compared for diagnoses made from the DELV-NR and participants' clinical status prior to recruitment. In a second analysis, the authors used results from the first analysis to make evidence-based adjustments in the estimates of DELV-NR diagnostic accuracy. RESULTS Accuracy of the DELV-NR relative to LS profiles was greater than that of prior diagnoses, indicating that the DELV-NR was an improvement over preexisting diagnoses for this group. Specificity met conventional standards, but sensitivity was somewhat low. Reanalysis using the positive and negative predictive power of the preexisting diagnosis in a discrepant-resolution procedure revealed that estimates for sensitivity and specificity for the DELV-NR were .85 and .93, respectively. CONCLUSION The authors found that, even after making allowances for the imperfection of available gold standards, clinical decisions made with the DELV-NR achieved high values on conventional measures of diagnostic accuracy.
DISK PUMP FEASIBILITY INVESTIGATION,
system as an inducer and/or mainstage pump for liquid rocket applications. This investigation consisted of the analysis, design, and test of a disk...pumping action is a function of the viscous properties of the pumped fluid. (2) The pump does not require the conventional pump lifting forces. ( 3 ...with no apparent head deterioration. The representative maximum suction specific speed at a 3 % head drop was never reached. The pump demonstrated
Record power, ultra-broadband supercontinuum source based on highly GeO2 doped silica fiber.
Jain, D; Sidharthan, R; Moselund, P M; Yoo, S; Ho, D; Bang, O
2016-11-14
We demonstrate highly germania doped fibers for mid-infrared supercontinuum generation. Experiments ensure a highest output power of 1.44 W for a broadest spectrum from 700 nm to 3200 nm and 6.4 W for 800 nm to 2700 nm from these fibers, while being pumped by a broadband Erbium-Ytterbium doped fiber based master oscillator power amplifier. The effect of repetition frequency of pump source and length of germania-doped fiber has also been investigated. Further, germania doped fiber has been pumped by conventional supercontinuum source based on silica photonic crystal fiber supercontinuum source. At low power, a considerable broadening of 200-300 nm was observed. Further broadening of spectrum was limited due to limited power of pump source. Our investigations reveal the unexploited potential of germania doped fiber for mid-infrared supercontinuum generation. These measurements ensure the potential of germania based photonic crystal fiber or a step-index fiber supercontinuum source for high power ultra-broad band emission being by pumped a 1060 nm or a 1550 nm laser source. To the best of our knowledge, this is the record power, ultra-broadband, and all-fiberized supercontinuum light source based on silica and germania fiber ever demonstrated to the date.
A pump monitoring approach to irrigation pumping plant testing
USDA-ARS?s Scientific Manuscript database
The conventional approach for evaluating irrigation pumping plant performance has been an instantaneous spot measurement approach. Using this method, the tester measures the necessary work and energy use parameters to determine overall pumping plant performance. The primary limitation of this appr...
RECOVERY OF VOCS FROM SURFACTANT SOLUTION BY PERVAPORATION
Surfactant-based processes are emerging as promising technologies to enhance conventional pump-and-treat methods for remediating soils contaminated with nonaqueous phase liquids (NAPLs), primarily due to the potential to significantly reduce the remediation time. In order to reus...
Hencken, Kenneth R.; Sartor, George B.
2004-08-03
An electrokinetic pump in which the porous dielectric medium of conventional electrokinetic pumps is replaced by a patterned microstructure. The patterned microstructure is fabricated by lithographic patterning and etching of a substrate and is formed by features arranged so as to create an array of microchannels. The microchannels have dimensions on the order of the pore spacing in a conventional porous dielectric medium. Embedded unitary electrodes are vapor deposited on either end of the channel structure to provide the electric field necessary for electroosmotic flow.
Zhang, Hong-Xi; Fu, Jun-Fen; Lai, Can; Tian, Feng-Yu; Su, Xiao-Li; Huang, Ke
2018-04-30
To determine the feasibility of balanced steady-state free precession (b-SSFP) imaging for measuring hepatic steatosis in obese children and adolescents, using proton magnetic resonance spectroscopy ( 1 H MRS) as reference standard. 182 obese Chinese paediatric patients underwent conventional T1-weighted dual echo MRI, 1 H MRS and b-SSFP imaging for non-invasive assessment of hepatic steatosis. There was a strong positive correlation between liver fat fraction (FF) on T1-weighted dual echo MRI and 1 H MRS-determined liver fat content (LFC) (r = 0.964, p < .001), and a strong negative correlation between the ratio of liver signal intensity (SI) to spleen SI (L/S) on b-SSFP and LFC (r = -0.896, p < .001). ROC curve analysis based on a diagnostic threshold of 1 H MRS-determined LFC >50 mg/g (>5 % by wet weight) showed areas under the curves for FF and L/S at 0.989 (0.976-1.000) and 0.926 (0.888-0.964), respectively. Optimal FF and L/S cut-off values identified patients with hepatic steatosis with 97.9 % and 86.5 % sensitivity and 93.4 % and 93.4 % specificity, respectively. Following further validation, b-SSFP at 1.5T has potential as a feasible technique for evaluation of hepatic steatosis in obese paediatric patients with limited breath-holding capacity. • L/S on b-SSFP images closely correlated with 1 H MRS-determined LFC. • b-SSFP has high diagnostic accuracy for hepatic steatosis in obese children. • 100% of obese paediatric subjects are imaged successfully using b-SSFP sequence. • b-SSFP has potential to evaluate hepatic steatosis in children with poor breath-hold.
A computerized system to evaluate volumetric infusion pumps.
Kobayashi, S; Ogata, T
1992-01-01
A computerized system was developed to examine the performance characteristics of infusion pumps. This system collects solution delivered by an infusion pump through an intravenous needle into a collection vessel. Using an inductor-type weight sensor and a semiconductor type of strain-gauge pressure sensor, the weight of the collection vessel and the pressure at the needle were monitored over a specific period (the sampling time), and changes in pressure, flow rate, and volume of fluid were calculated. This system was applied to five volumetric infusion pumps with different pumping mechanisms. Test conditions involved two different solutions, two sizes of needle gauge, and seven flow rates, for a total of 28 measurements per pump. Results showed considerable variation in the infusion pumps' performances based on differences in these indices. Use of an inductance weight sensor as a means to evaluate gravimetric performance appears to be an improvement over conventional methods, which use analytical balances for data generation. The results indicate that this system will be useful in evaluating the performances of commercially available infusion pumps as well as those in development.
Identifying Attributes of CO2 Leakage Zones in Shallow Aquifers Using a Parametric Level Set Method
NASA Astrophysics Data System (ADS)
Sun, A. Y.; Islam, A.; Wheeler, M.
2016-12-01
Leakage through abandoned wells and geologic faults poses the greatest risk to CO2 storage permanence. For shallow aquifers, secondary CO2 plumes emanating from the leak zones may go undetected for a sustained period of time and has the greatest potential to cause large-scale and long-term environmental impacts. Identification of the attributes of leak zones, including their shape, location, and strength, is required for proper environmental risk assessment. This study applies a parametric level set (PaLS) method to characterize the leakage zone. Level set methods are appealing for tracking topological changes and recovering unknown shapes of objects. However, level set evolution using the conventional level set methods is challenging. In PaLS, the level set function is approximated using a weighted sum of basis functions and the level set evolution problem is replaced by an optimization problem. The efficacy of PaLS is demonstrated through recovering the source zone created by CO2 leakage into a carbonate aquifer. Our results show that PaLS is a robust source identification method that can recover the approximate source locations in the presence of measurement errors, model parameter uncertainty, and inaccurate initial guesses of source flux strengths. The PaLS inversion framework introduced in this work is generic and can be adapted for any reactive transport model by switching the pre- and post-processing routines.
Kado, Yuichiro; Obokata, Masaru; Nagata, Yasufumi; Ishizu, Tomoko; Addetia, Karima; Aonuma, Kazutaka; Kurabayashi, Masahiko; Lang, Roberto M; Takeuchi, Masaaki; Otsuji, Yutaka
2016-11-01
The aim of this study was to test the hypothesis that prognosis in patients with cardiac amyloidosis is closely coupled with amyloid burden in all four cardiac chambers. The goal was to evaluate longitudinal strain (LS) in each cardiac chamber and to determine whether LS in specific cardiac chambers is preferentially associated with prognosis over conventional two-dimensional echocardiographic parameters in patients with cardiac amyloidosis. Patients with two phenotypes of left ventricular (LV) hypertrophy (cardiac amyloidosis in 55 patients and nonobstructive hypertrophic cardiomyopathy in 40 patients) and 55 healthy subjects were retrospectively enrolled for the simultaneous assessment of LS of all four cardiac chambers in the apical four-chamber view. Patients with cardiac amyloidosis were followed up to record major adverse cardiovascular events, including cardiac death, heart transplantation, nonfatal myocardial infarction, ventricular tachyarrhythmia, and exacerbation of heart failure requiring hospitalization. LS in each chamber was significantly depressed in patients with both LV hypertrophy phenotypes compared with healthy subjects. Right atrial LS was significantly lower in patients with cardiac amyloidosis than those with nonobstructive hypertrophic cardiomyopathy after adjusting for LV ejection fraction and LV mass index. During a median follow-up period of 10 months, major adverse cardiovascular events developed in 22 patients with cardiac amyloidosis. Four-chamber LS were significantly associated with major adverse cardiovascular events, with incremental value over traditional echocardiographic parameters. Cardiac amyloidosis involves all cardiac chambers, and thus, chamber-specific strain analysis may be useful to assess the total cumulative burden of cardiac dysfunction. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Berry, Christopher; Hashemi, Mohammad Reza; Unlu, Mehmet; Jarrahi, Mona
2013-07-08
In this video article we present a detailed demonstration of a highly efficient method for generating terahertz waves. Our technique is based on photoconduction, which has been one of the most commonly used techniques for terahertz generation (1-8). Terahertz generation in a photoconductive emitter is achieved by pumping an ultrafast photoconductor with a pulsed or heterodyned laser illumination. The induced photocurrent, which follows the envelope of the pump laser, is routed to a terahertz radiating antenna connected to the photoconductor contact electrodes to generate terahertz radiation. Although the quantum efficiency of a photoconductive emitter can theoretically reach 100%, the relatively long transport path lengths of photo-generated carriers to the contact electrodes of conventional photoconductors have severely limited their quantum efficiency. Additionally, the carrier screening effect and thermal breakdown strictly limit the maximum output power of conventional photoconductive terahertz sources. To address the quantum efficiency limitations of conventional photoconductive terahertz emitters, we have developed a new photoconductive emitter concept which incorporates a plasmonic contact electrode configuration to offer high quantum-efficiency and ultrafast operation simultaneously. By using nano-scale plasmonic contact electrodes, we significantly reduce the average photo-generated carrier transport path to photoconductor contact electrodes compared to conventional photoconductors (9). Our method also allows increasing photoconductor active area without a considerable increase in the capacitive loading to the antenna, boosting the maximum terahertz radiation power by preventing the carrier screening effect and thermal breakdown at high optical pump powers. By incorporating plasmonic contact electrodes, we demonstrate enhancing the optical-to-terahertz power conversion efficiency of a conventional photoconductive terahertz emitter by a factor of 50 (10).
Carlson, J A; Ambros, R; Malfetano, J; Ross, J; Grabowski, R; Lamb, P; Figge, H; Mihm, M C
1998-09-01
The histological changes of lichen sclerosus (LS) are frequently found in association with vulvar squamous cell carcinoma (SCC). The importance of chronic inflammation and scarring in oncogenesis is well recognized. Thirty-two patients with symptomatic vulvar LS and 60 with vulvar SCC were studied. Paraffin sections of vulvar LS, and three controls groups (acute scars, normal vulva, and vulvar lichen simplex chronicus [LSC]) were investigated with a panel of seven tissue markers and for DNA content in areas without vulvar intraepithelial neoplasia (VIN). All published cases to date of vulvar LS associated with SCC were reviewed. Of the cohort of symptomatic vulvar LS patients (mean/median age, 60 years), 9% developed VIN lesions and 21% invasive SCC; symptomatic LS preceded the carcinoma by a mean of 4 years (range, 1 to 23 years). Second and third primary tumors developed in three of these patients. Of the series of 60 patients presenting with vulvar SCCa, the clinical setting and histological features of SCCs associated with LS were significantly distinctive compared with SCCas without LS: SCCs associated with LS occurred in an older age-group (74 v 65 years; P = .01), were located on the clitoris (41% v 5%; P = .003), were of conventional SCCa type (85% v 57%; P = .02), were associated with a prominent fibromyxoid stromal response (46% v 10%; P = .004), were not associated with VIN 3 (SCC in situ) (5% v 67%; P = .02) and diffusely expressed tumor suppressor gene product p53 (43% v 19%; P = .01) and cytokine TGF-beta (33% v 9%; P = .05). The epidermis of vulvar LS was similar to that of acute scars and differed significantly compared with normal vulva with respect to keratinocytic expression of markers to keratin AE 1, involucrin and filaggrin, epidermal thickness (0.13 mm [LS] v 0.05 mm [normal]; P < .03), and proliferative index by PCNA and Mib-1 labeling (53/60 [LS] v 15/19 [normal] per 200 basal cells [bc]; P < .003). Vulvar LS showed significantly higher expression of p53 than all three control groups (80 [LS] v 3 [normal]/44 [acute scar]/28 [LSC] per 200 bc; P < .008), and aneuploidy (33% v diploid controls) in the absence of VIN. Comparing LS with and without associated SCCa found significant increases in age of patients (74 v 66 years; P = .001), and DNA aneuploidy (52% v 11%; P = .0001) and no differences in epidermal thickness, sclerotic thickness, proliferative index, or p53 expression. However, those cases of LS with an aneuploid DNA content showed significantly elevated p53 expression (88 v 60/200 bc; P = .01) and epidermal thickness (0.16 v 0.11 mm; P = .005) compared with LS with a diploid DNA content. Review of published cases supports an association between LS and vulvar SCC. The phenomenon of chronic inflammation and scarring giving rise to carcinoma has been well documented. Vulvar lichen sclerosus (LS) is an inflammatory dermatosis characterized by clinicopathologic persistence and hypocellular fibrosis (sclerosis). A subset of vulvar SCCs is significantly associated with the presence of LS and diffusely express the p53 gene product. Keratinocytes affected by LS show a proliferative phenotype and can exhibit markers of neoplastic progression such as increased p53 expression and DNA aneuploidy. As a chronic scarring inflammatory dermatosis, vulvar LS could act as both "initiator and promoter" of carcinogenesis, explaining the frequent coexistence of these diseases. Because keratinocytes of LS significantly express tumor suppressor gene p53 protein, the p53 gene may be involved early in this proposed pathway of carcinogenesis.
Well development by jetting using coiled tubing and simultaneous pumping.
Rosberg, Jan-Erik; Bjelm, Leif
2009-01-01
During flow testing of a deep, 1927-m, gravel packed screen completed well, it became apparent that well development was needed to increase productivity. A hydrojetting system using coiled tubing in combination with simultaneous pumping was developed and tested and found to be successful. To verify whether the jetting improved the well, the results of a pumping test conducted before and after the jetting operation are compared. In addition, flowmeter logging and hydraulic properties obtained from pumping tests conducted during the jetting operation were also used to verify the improvements. Hydrojetting in combination with simultaneous pumping proved to be an effective cleaning method. After 100 min of pumping, around 110 m less drawdown and 15 L/s higher average flow rate were obtained compared to the values before the jetting operation. The skin factor was positive before the jetting operation and negative thereafter, thus providing additional evidence of improvements of the well. The flowmeter data also confirmed the improvements and were valuable in optimizing the jetting operation. It was also found, from the short-term pumping tests conducted during the jetting operation, that the Hantush-Jacob method for leaky confined aquifers is a valuable indicator of the well development. The combination of methods used for the well development in this case can easily be applied on other deep well projects to obtain a controlled and time-efficient well development. Copyright © 2009 The Author(s). Journal Compilation © 2009 National Ground Water Association.
Efficient single-mode operation of a cladding-pumped ytterbium-doped helical-core fiber laser.
Wang, P; Cooper, L J; Sahu, J K; Clarkson, W A
2006-01-15
A novel approach to achieving robust single-spatial-mode operation of cladding-pumped fiber lasers with multimode cores is reported. The approach is based on the use of a fiber geometry in which the core has a helical trajectory within the inner cladding to suppress laser oscillation on higher-order modes. In a preliminary proof-of-principle study, efficient single-mode operation of a cladding-pumped ytterbium-doped helical-core fiber laser with a 30 microm diameter core and a numerical aperture of 0.087 has been demonstrated. The laser yielded 60.4 W of output at 1043 nm in a beam with M2 < 1.4 for 92.6 W launched pump power from a diode stack at 976 nm. The slope efficiency at pump powers well above threshold was approximately 84%, which compares favorably with the slope efficiencies achievable with conventional straight-core Yb-doped double-clad fiber lasers.
Performance Analysis of a Wind Turbine Driven Swash Plate Pump for Large Scale Offshore Applications
NASA Astrophysics Data System (ADS)
Buhagiar, D.; Sant, T.
2014-12-01
This paper deals with the performance modelling and analysis of offshore wind turbine-driven hydraulic pumps. The concept consists of an open loop hydraulic system with the rotor main shaft directly coupled to a swash plate pump to supply pressurised sea water. A mathematical model is derived to cater for the steady state behaviour of entire system. A simplified model for the pump is implemented together with different control scheme options for regulating the rotor shaft power. A new control scheme is investigated, based on the combined use of hydraulic pressure and pitch control. Using a steady-state analysis, the study shows how the adoption of alternative control schemes in a the wind turbine-hydraulic pump system may result in higher energy yields than those from a conventional system with an electrical generator and standard pitch control for power regulation. This is in particular the case with the new control scheme investigated in this study that is based on the combined use of pressure and rotor blade pitch control.
Commercialization of PV-powered pumping systems for use in utility PV service programs. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1997-03-01
The project described in this report was a commercialization effort focused on cost-effective remote water pumping systems for use in utility-based photovoltaic (PV) service programs. The project combined a commercialization strategy tailored specifically for electric utilities with the development of a PV-powered pumping system that operates conventional ac pumps rather than relying on the more expensive and less reliable PV pumps on the market. By combining these two attributes, a project goal was established of creating sustained utility purchases of 250 PV-powered water pumping systems per year. The results of each of these tasks are presented in two parts containedmore » in this Final Summary Report. The first part summarizes the results of the Photovoltaic Services Network (PSN) as a new business venture, while the second part summarizes the results of the Golden Photon system installations. Specifically, results and photographs from each of the system installations are presented in this latter part.« less
ERIC Educational Resources Information Center
Koutsouris, George; Norwich, Brahm; Fujita, Taro; Ralph, Thomas; Adlam, Anna; Milton, Fraser
2017-01-01
This article presents an evaluation of distance technology used in a novel Lesson Study (LS) approach involving a dispersed LS team for inter-professional purposes. A typical LS model with only school teachers as team members was modified by including university-based lecturers with the school-based teachers, using video-conferencing and online…
[Measurement of soil organic matter and available K based on SPA-LS-SVM].
Zhang, Hai-Liang; Liu, Xue-Mei; He, Yong
2014-05-01
Visible and short wave infrared spectroscopy (Vis/SW-NIRS) was investigated in the present study for measurement of soil organic matter (OM) and available potassium (K). Four types of pretreatments including smoothing, SNV, MSC and SG smoothing+first derivative were adopted to eliminate the system noises and external disturbances. Then partial least squares regression (PLSR) and least squares-support vector machine (LS-SVM) models were implemented for calibration models. The LS-SVM model was built by using characteristic wavelength based on successive projections algorithm (SPA). Simultaneously, the performance of LSSVM models was compared with PLSR models. The results indicated that LS-SVM models using characteristic wavelength as inputs based on SPA outperformed PLSR models. The optimal SPA-LS-SVM models were achieved, and the correlation coefficient (r), and RMSEP were 0. 860 2 and 2. 98 for OM and 0. 730 5 and 15. 78 for K, respectively. The results indicated that visible and short wave near infrared spectroscopy (Vis/SW-NIRS) (325 approximately 1 075 nm) combined with LS-SVM based on SPA could be utilized as a precision method for the determination of soil properties.
NASA Technical Reports Server (NTRS)
Kong, Jeffrey
1994-01-01
This thesis focuses on the subject of the accuracy of parameter estimation and system identification techniques. Motivated by a complicated load measurement from NASA Dryden Flight Research Center, advanced system identification techniques are needed. The objective of this problem is to accurately predict the load experienced by the aircraft wing structure during flight determined from a set of calibrated load and gage response relationship. We can then model the problem as a black box input-output system identification from which the system parameter has to be estimated. Traditional LS (Least Square) techniques and the issues of noisy data and model accuracy are addressed. A statistical bound reflecting the change in residual is derived in order to understand the effects of the perturbations on the data. Due to the intrinsic nature of the LS problem, LS solution faces the dilemma of the trade off between model accuracy and noise sensitivity. A method of conflicting performance indices is presented, thus allowing us to improve the noise sensitivity while at the same time configuring the degredation of the model accuracy. SVD techniques for data reduction are studied and the equivalence of the Correspondence Analysis (CA) and Total Least Squares Criteria are proved. We also looked at nonlinear LS problems with NASA F-111 data set as an example. Conventional methods are neither easily applicable nor suitable for the specific load problem since the exact model of the system is unknown. Neural Network (NN) does not require prior information on the model of the system. This robustness motivated us to apply the NN techniques on our load problem. Simulation results for the NN methods used in both the single load and the 'warning signal' problems are both useful and encouraging. The performance of the NN (for single load estimate) is better than the LS approach, whereas no conventional approach was tried for the 'warning signals' problems. The NN design methodology is also presented. The use of SVD, CA and Collinearity Index methods are used to reduce the number of neurons in a layer.
Osmotic Drug Delivery System as a Part of Modified Release Dosage Form
Keraliya, Rajesh A.; Patel, Chirag; Patel, Pranav; Keraliya, Vipul; Soni, Tejal G.; Patel, Rajnikant C.; Patel, M. M.
2012-01-01
Conventional drug delivery systems are known to provide an immediate release of drug, in which one can not control the release of the drug and can not maintain effective concentration at the target site for longer time. Controlled drug delivery systems offer spatial control over the drug release. Osmotic pumps are most promising systems for controlled drug delivery. These systems are used for both oral administration and implantation. Osmotic pumps consist of an inner core containing drug and osmogens, coated with a semipermeable membrane. As the core absorbs water, it expands in volume, which pushes the drug solution out through the delivery ports. Osmotic pumps release drug at a rate that is independent of the pH and hydrodynamics of the dissolution medium. The historical development of osmotic systems includes development of the Rose-Nelson pump, the Higuchi-Leeper pumps, the Alzet and Osmet systems, the elementary osmotic pump, and the push-pull system. Recent advances include development of the controlled porosity osmotic pump, and systems based on asymmetric membranes. This paper highlights the principle of osmosis, materials used for fabrication of pumps, types of pumps, advantages, disadvantages, and marketed products of this system. PMID:22852100
Reimer, C; Lødrup, A B; Smith, G; Wilkinson, J; Bytzer, P
2016-04-01
Many reflux patients remain symptomatic on a standard dose of proton pump inhibitor (PPI). Alginates decrease the number of reflux events by forming a raft on top of the stomach content and thus offer a supplemental mechanism of action to acid suppression. To assess the efficacy of an alginate (Gaviscon Advance, Reckitt Benckiser, Slough, UK) on reflux symptoms in patients with persistent symptoms despite once daily PPI. This was a multicentre, randomised, placebo-controlled, 7-day double-blind trial preceded by a 7-day run-in period. Reflux symptoms were assessed using the Heartburn Reflux Dyspepsia Questionnaire (HRDQ). Based on symptom score during run-in, eligible patients were randomised to Gaviscon Advance 10 mL four times a day or placebo in addition to a once daily PPI. The primary endpoint was change in HRDQ score post-treatment compared to baseline. One hundred and thirty-six patients were randomised. Change in HRDQ reflux score was significantly greater for Gaviscon Advance (mean: -5.0, s.d.: 4.7) than for placebo (mean: -3.5, s.d.: 5.5) with an LS mean difference of 1.6 [95% CI -3.1 to -0.1], P = 0.03. A decrease in the mean (s.d.) number of nights with symptoms was observed from 3.6 (2.8) to 3.0 (3.0) in the placebo group and from 3.9 (2.8) to 2.2 (2.7) for the Gaviscon Advance group. This reduction was significantly greater in the Gaviscon Advance group than in the placebo group [LS mean difference = -0.9, 95% CI (-1.6 to -0.2), P < 0.01]. In patients with residual reflux symptoms despite PPI treatment, adding an alginate offers additional decrease in the burden of reflux symptoms (EudraCT/IND Number: 2011-005486-21). © 2016 John Wiley & Sons Ltd.
Thermal and economic assessment of ground-coupled storage for residential solar heat pump systems
NASA Astrophysics Data System (ADS)
Choi, M. K.; Morehouse, J. H.
1980-11-01
This study performed an analysis of ground-coupled stand-alone and series configured solar-assisted liquid-to-air heat pump systems for residences. The year-round thermal performance of these systems for space heating, space cooling, and water heating were determined by simulation and compared against non-ground-coupled solar heat pump systems as well as conventional heating and cooling systems in three geographic locations: Washington, D.C., Fort Worth, Tex., and Madison, Wis. The results indicate that without tax credits a combined solar/ground-coupled heat pump system for space heating and cooling is not cost competitive with conventional systems. Its thermal performance is considerably better than non-ground-coupled solar heat pumps in Forth Worth. Though the ground-coupled stand-alone heat pump provides 51% of the heating and cooling load with non-purchased energy in Forth Worth, its thermal performance in Washington and Madison is poor.
NASA Technical Reports Server (NTRS)
Heyman, Joseph S.
1993-01-01
Pump uses acoustic-radiation forces. Momentum transferred from sound waves to sound-propagating material in way resulting in net pumping action on material. Acoustic pump is solid-state pump. Requires no moving parts, entirely miniaturized, and does not invade pumped environment. Silent, with no conventional vibration. Used as pump for liquid, suspension, gas, or any other medium interacting with radiation pressure. Also used where solid-state pump needed for reliability and controllability. In microgravity environment, device offers unusual control for low flow rates. For medical or other applications in which contamination cannot be allowed, offers noninvasive pumping force.
1990-09-01
by damage. SHPREP When not zero, all parts repaired at an operating base are shipped to the base that is selected with the SEND logic in the CONTRL ...nominal (at rest) skin temperature when each MOPP is worn, the pumping factor (y), the insulation factor (CLO), and the permeability factor (IM). The...temiperature is taken to be 35 0C, and 36"C for MOPP #5; the pumping factor (y) ranges from 0.200 to 0.270, the insulation factor (CLO) from 1.70 to
Song, Hu; Song, Jun; Liang, Yong; Fu, Wei; Xu, Yixin; Zheng, Junnian; Xu, Wei
2014-08-01
To compare the immune function after laparoscopic surgery (LS) and conventional open surgery(OS) for colorectal cancer (CRC). PubMed, EMBASE, the Cochrane Library, China National Knowledge Infrastructure (CNKI), and Wanfang Database were systematically searched for randomized controlled trials published before August 2013 concerning the immunological difference between LS and OS. Data extraction was performed independently by two reviewers and data analysis was performed using Review Manager ver. 4.3.1. Twelve studies including 638 patients (307 in LS group and 331 in OS group) were eligible for analysis. Overall analysis demonstrated that no significant differences were identified for blood C-reactive protein level on postoperative days (POD) 0-1 (P=0.40), plasma lymphocyte count on POD 1-3 (P=0.92) and POD 4-7 (P=0.64), plasma CD4⁺ T cell count on POD 1-7 (P=0.63), plasma CD8⁺ T cell count on POD 4-7 (P=0.09), and plasma NK cell count POD 1-3 (P=0.34) as well as POD 4-7 (P=0.46). Data analysis also showed that a significantly lower serum level of IL-6 on POD 0-1 after LS (WMD=-25.03, 95% CI:-34.06 to -15.99, P=0.000), and a significantly higher plasma level of CD8⁺ T cell count on POD 1-3 after LS(WMD=0.05, 95% CI:0.01 to 0.08, P=0.004). Although postoperatively short-term humoral immune function trends to be better after LS for CRC compared to OS, there is no sufficient evidence to support superior preservation of global immune function after acute reactive phase.
Zürch, M; Jung, R; Späth, C; Tümmler, J; Guggenmos, A; Attwood, D; Kleineberg, U; Stiel, H; Spielmann, C
2017-07-13
Coherent diffraction imaging (CDI) in the extreme ultraviolet has become an important tool for nanoscale investigations. Laser-driven high harmonic generation (HHG) sources allow for lab scale applications such as cancer cell classification and phase-resolved surface studies. HHG sources exhibit excellent coherence but limited photon flux due poor conversion efficiency. In contrast, table-top soft X-ray lasers (SXRL) feature excellent temporal coherence and extraordinary high flux at limited transverse coherence. Here, the performance of a SXRL pumped at moderate pump energies is evaluated for CDI and compared to a HHG source. For CDI, a lower bound for the required mutual coherence factor of |μ 12 | ≥ 0.75 is found by comparing a reconstruction with fixed support to a conventional characterization using double slits. A comparison of the captured diffraction signals suggests that SXRLs have the potential for imaging micron scale objects with sub-20 nm resolution in orders of magnitude shorter integration time compared to a conventional HHG source. Here, the low transverse coherence diameter limits the resolution to approximately 180 nm. The extraordinary high photon flux per laser shot, scalability towards higher repetition rate and capability of seeding with a high harmonic source opens a route for higher performance nanoscale imaging systems based on SXRLs.
Ground Source Heat Pumps vs. Conventional HVAC: A Comparison of Economic and Environmental Costs
2009-03-26
of systems are surface water heat pumps (SWHPs), ground water heat pumps (GWHPs), and ground coupled heat pumps ( GCHPs ) (Kavanaugh & Rafferty, 1997...Kavanaugh & Rafferty, 1997). Ground Coupled Heat Pumps (Closed-Loop Ground Source Heat Pumps) GCHPs , otherwise known as closed-loop GSHPs, are the...Significant confusion has arisen through the use of GCHP and closed-loop GSHP terminology. Closed-loop GSHP is the preferred nomenclature for this
Zinn, W.H.
1958-07-01
A fast nuclear reactor system ls described for producing power and radioactive isotopes. The reactor core is of the heterogeneous, fluid sealed type comprised of vertically arranged elongated tubular fuel elements having vertical coolant passages. The active portion is surrounded by a neutron reflector and a shield. The system includes pumps and heat exchangers for the primary and secondary coolant circuits. The core, primary coolant pump and primary heat exchanger are disposed within an irapenforate tank which is filled with the primary coolant, in this case a liquid metal such as Na or NaK, to completely submerge these elements. The tank is completely surrounded by a thick walled concrete shield. This reactor system utilizes enriched uranium or plutonium as the fissionable material, uranium or thorium as a diluent and thorium or uranium containing less than 0 7% of the U/sup 235/ isotope as a fertile material.
Thermal Lens Measurement in Diode-Pumped Nd:YAG Zig-Zag Slab
NASA Technical Reports Server (NTRS)
Smoak, M. C.; Kay, R. B.; Coyle, D. B.; Hopf, D.
1998-01-01
A major advantage that solid state zig-zag slab lasers have over conventional rod-based designs is that a much weaker thermal lens is produced in the slab when side-pumped with Quasi-CW laser diode arrays, particularly if the pump radiation is kept well away from the Brewster-cut ends. This paper reports on a rather strong thermal lens produced when diode pump radiation is collimated into a narrow portion of the zig-zag slab. The collimation of multi-bar pump packages to increase brightness and improve overlap is a direct consequence of designs which seek to maximize performance and efficiency. Our slab design employed a 8.1 cm x 2.5 mm x 5 mm slab with opposing Brewster end faces. It was pumped through the 2.5 mm direction by seven laser diode array packages, each housing four 6OW diode bars, 1 cm in width. The pump face, anti-reflection (AR) coated at 809 nm, was 6.8 cm in width and the 8.1 cm opposing side, high-reflection (HR) coated at 809 nm, reflected the unabsorbed pump beam for a second pass through the slab.
The Debye light scattering equation's scaling relation reveals the purity of synthetic dendrimers
NASA Astrophysics Data System (ADS)
Tseng, Hui-Yu; Chen, Hsiao-Ping; Tang, Yi-Hsuan; Chen, Hui-Ting; Kao, Chai-Lin; Wang, Shau-Chun
2016-03-01
Spherical dendrimer structures cannot be structurally modeled using conventional polymer models of random coil or rod-like configurations during the calibration of the static light scattering (LS) detectors used to determine the molecular weight (M.W.) of a dendrimer or directly assess the purity of a synthetic compound. In this paper, we used the Debye equation-based scaling relation, which predicts that the static LS intensity per unit concentration is linearly proportional to the M.W. of a synthetic dendrimer in a dilute solution, as a tool to examine the purity of high-generational compounds and to monitor the progress of dendrimer preparations. Without using expensive equipment, such as nuclear magnetic resonance or mass spectrometry, this method only required an affordable flow injection set-up with an LS detector. Solutions of the purified dendrimers, including the poly(amidoamine) (PAMAM) dendrimer and its fourth to seventh generation pyridine derivatives with size range of 5-9 nm, were used to establish the scaling relation with high linearity. The use of artificially impure mixtures of six or seven generations revealed significant deviations from linearity. The raw synthesized products of the pyridine-modified PAMAM dendrimer, which included incompletely reacted dendrimers, were also examined to gauge the reaction progress. As a reaction toward a particular generational derivative of the PAMAM dendrimers proceeded over time, deviations from the linear scaling relation decreased. The difference between the polydispersity index of the incompletely converted products and that of the pure compounds was only about 0.01. The use of the Debye equation-based scaling relation, therefore, is much more useful than the polydispersity index for monitoring conversion processes toward an indicated functionality number in a given preparation.
NASA Astrophysics Data System (ADS)
Chen, Ye; Yin, Chengbo; Wei, Linpeng; Glaser, Adam K.; Abeytunge, Sanjee; Peterson, Gary; Mandella, Michael J.; Sanai, Nader; Rajadhyaksha, Milind; Liu, Jonathan T.
2017-02-01
Considerable efforts have been recently undertaken to develop miniature optical-sectioning microscopes for in vivo microendoscopy and point-of-care pathology. These devices enable in vivo interrogation of disease as a real-time and noninvasive alternative to gold-standard histopathology, and therefore could have a transformative impact for the early detection of cancer as well as for guiding tumor-resection procedures. Regardless of the specific modality, various trade-offs in size, speed, field of view, resolution, contrast, and sensitivity are necessary to optimize a device for a particular application. Here, a miniature MEMS-based line-scanned dual-axis confocal (LS-DAC) microscope, with a 12-mm diameter distal tip, has been developed for point-of-care pathology. The dual-axis architecture has demonstrated superior rejection of out-of-focus and multiply scattered photons compared to a conventional single-axis confocal configuration. The use of line scanning enables fast frame rates (≥15 frames/sec), which mitigates motion artifacts of a handheld device during clinical use. We have developed a method to actively align the illumination and collection beams in this miniature LS-DAC microscope through the use of a pair of rotatable alignment mirrors. Incorporation of a custom objective lens, with a small form factor for in vivo application, enables the device to achieve an axial and lateral resolution of 2.0 and 1.1 microns, respectively. Validation measurements with reflective targets, as well as in vivo and ex vivo images of tissues, demonstrate that this high-speed LS-DAC microscope can achieve high-contrast imaging of fluorescently labeled tissues with sufficient sensitivity for applications such as oral cancer detection and guiding brain-tumor resections.
NASA Astrophysics Data System (ADS)
Boyer, Craig N.; Osterman, Steven N.; Thonnard, Stefan E.; McCoy, Robert P.; Williams, J. Z.; Parker, S. E.
1994-09-01
A facility for calibrating far ultraviolet and extreme ultraviolet instruments has recently been completed at the Naval Research Laboratory. Our vacuum calibration vessel is 2-m in length, 1.67-m in diameter, and can accommodate optical test benches up to 1.2-m wide by 1.5-m in length. A kinematically positioned frame with four axis precision pointing capability of 10 microns for linear translation and .01 degrees for rotation is presently used during vacuum optical calibration of SSULI. The chamber was fabricated from 304 stainless steel and polished internally to reduce surface outgassing. A dust-free environment is maintained at the rear of the vacuum chamber by enclosing the 2-m hinged vacuum access door in an 8 ft. by 8 ft. class 100 clean room. Every effort was made to obtain an oil-free environment within the vacuum vessel. Outgassing products are continually monitored with a 1 - 200 amu residual gas analyzer. An oil-free claw and vane pump evacuates the chamber to 10-2 torr through 4 in. diameter stainless steel roughing lines. High vacuum is achieved and maintained with a magnetically levitated 480 l/s turbo pump and a 3000 l/s He4 cryopump. Either of two vacuum monochrometers, a 1-m f/10.4 or a 0.2-m f/4.5 are coaxially aligned with the optical axis of the chamber and are used to select single UV atomic resonance lines from a windowless capillary or penning discharge UV light source. A calibrated channeltron detector is coaxially mounted with the SSULI detector during calibration. All vacuum valves, the cooling system for the cryopump compressor, and the roughing pump are controlled through optical fibers which are interfaced to a computer through a VME board. Optical fibers were chosen to ensure that complete electrical isolation is maintained between the computer and the vacuum system valves-solenoids and relays.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Minami, Yasuo; Horiuchi, Kohei; Masuda, Kaisei
We have demonstrated accurate observations of terahertz (THz) dielectric response due to photoexcited carriers in a Si plate via single-shot optical-pump and THz-probe spectroscopy. In contrast to conventional THz time-domain spectroscopy, this spectroscopic technique allows single-shot detection of the THz response of materials at a given delay time between the pump and THz pulses, thereby sufficiently extending the time interval between the pump pulses. As a result, we can accurately measure the dielectric properties of materials, while avoiding artifacts in the response caused by the accumulation of long-lived photoexcited carriers. Using our single-shot scheme, the transmittance of a Si platemore » was measured in the range of 0.5–2.5 THz with different pump fluences. Based on a Drude model analysis, the optically induced complex dielectric constant, plasma frequency, and damping rate in the THz region were quantitatively evaluated.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crisp, T.E.; Nairn, R.W.; Strevett, K.A.
1998-12-31
A column study was conducted to evaluate the feasibility of using of coal combustion by-products (CCB) as alkaline materials in a field scale downflow constructed wetlands for acid mine drainage treatment. Five columns (15.24 cm in diameter and 91.44 cm high) were constructed and filled with a combination of spent mushroom substrate (SMS) and one of three alkaline materials (limestone, hydrated fly ash, or fluidized bed ash). The five mixtures utilized were 10% fluidized bed ash/40% limestone (FBA/LS), 10% fluidized bed ash (FBA), 50% limestone (LS), 50% hydrated fly ash (HFA),m and 50% sieved (>1.5 cm) hydrated fly ash (S.more » HFA) with the remainder as SMS on a w/w basis. Column received synthetic acid mine drainage containing: 400 mg/L iron, 59 mg/L aluminum, 11 mg/L manganese, 50% mg/L magnesium, 40 mg/L calcium, and 1200 mg/L sulfate for 5 months. Anoxic conditions in the influent reservoirs were maintained by a positive nitrogen pressure head. Flow rates of 2.0 mL/minute to each column were maintained by a multichannel peristaltic pump. For all columns, effluent acidity concentrations were less than influent acidity concentration (877{sup {minus}}30, n = 75f). Mean effluent acidity concentrations were 241 mg/L (FBA/LS), 186 mg/L (FBA), 419 mg/L (LS), {minus}28.5 mg/L (HFA), and 351 mg/L (S. HFA), respectively. While all column produced measurable alkalinity, only the HFA column produced a net alkaline discharge. The results of these column studies are applicable to the design and sizing of innovative field scale systems using alkaline-rich CCB`s.« less
Affordable Hybrid Heat Pump Clothes Dryer
DOE Office of Scientific and Technical Information (OSTI.GOV)
TeGrotenhuis, Ward E.; Butterfield, Andrew; Caldwell, Dustin D.
This project was successful in demonstrating the feasibility of a step change in residential clothes dryer energy efficiency by demonstrating heat pump technology capable of 50% energy savings over conventional standard-size electric dryers with comparable drying times. A prototype system was designed from off-the-shelf components that can meet the project’s efficiency goals and are affordable. An experimental prototype system was built based on the design that reached 50% energy savings. Improvements have been identified that will reduce drying times of over 60 minutes to reach the goal of 40 minutes. Nevertheless, the prototype represents a step change in efficiency overmore » heat pump dryers recently introduced to the U.S. market, with 30% improvement in energy efficiency at comparable drying times.« less
PUMP-AND-TREAT GROUND-WATER REMEDIATION: A GUIDE FOR DECISION MAKERS AND PRACTITIONERS
This guide presents decision makers with a foundation for evaluating the appropriateness of conventional or innovative approaches. An introduction to pump-and-treat ground-water remediation, the guide addresses the following questions: When is pump-and-treat an appropriate remedi...
Department of the Air Force. FY 1995 Budget Estimates. Military Construction and Family Housing
1994-02-01
monorail lift systems and provide AFFF fire protection system, and elevators. Renovate engineering and work areas; provide new air make-up unit and...135,0U0 SY 1,200 880-212 AFFF FIRE SUPPRESSION SYSTEM LS 800 FOR FUEL CELL TOTAL: 10,450 9b. Future Projects: Typical Planned Next Three Years: 111...PROTECT 2 EA 3,600 PH II & AFFF PUMPS/RESERVOIR TOTAL: 27,900 9b. Future Projects: Typical Planned Next Three Years: 442-758 WAREHOUSE 107,000 SF
Siqueira, Flavia R; Furukawa, Luzia N S; Oliveira, Ivone B; Heimann, Joel C
2016-02-01
A low-salt (LS) diet during pregnancy has been linked to insulin resistance in adult offspring, at least in the experimental setting. However, it remains unclear if this effect is due to salt restriction during early or late pregnancy. To better understand this phenomenon, 12-week-old female Wistar rats were fed a LS or normal-salt (NS) diet during gestation or a LS diet during either the first (LS10) or second (LS20) half of gestation. Glucose tolerance test, HOMA-IR, gene expression analysis and DNA methylation measurements were conducted for the Insr, Igf1, Igf1r, Ins1 and Ins2 genes in the livers of neonates and in the liver, white adipose tissue and muscle of 20-week-old male offspring. Birth weight was lower in the LS20 and LS animals compared with the NS and LS10 rats. In the liver, the Igf1 levels in the LS10, LS20 and LS neonates were lower than those in the NS neonates. Methylation of the Insr, Igf1r, Ins1 and Ins2 genes was influenced in a variable manner by low salt intake during pregnancy. Increased liver Igf1 methylation was observed in the LS and LS20 neonates compared with their NS and LS10 counterparts. Glucose intolerance was observed in adult offspring as an effect of low salt intake over the duration of pregnancy. Compared to the NS animals, the HOMA-IR was higher in the 12-week-old LS and 20-week-old LS-10 rats. Based on these results, it appears that the reason a LS diet during pregnancy induces a low birth weight is its negative correlation with Igf1 DNA methylation in neonates. Copyright © 2015 Elsevier Inc. All rights reserved.
Single-frequency oscillation of thin-disk lasers due to phase-matched pumping.
Vorholt, Christian; Wittrock, Ulrich
2017-09-04
We present a novel pump concept that should lead to single-frequency operation of thin-disk lasers without the need for etalons or other spectral filters. The single-frequency operation is due to matching the standing wave pattern of partially coherent pump light to the standing wave pattern of the laser light inside the disk. The output power and the optical efficiency of our novel pump concept are compared with conventional pumping. The feasibility of our pump concept was shown in previous experiments.
Universal Quantum Noise in Adiabatic Pumping
NASA Astrophysics Data System (ADS)
Herasymenko, Yaroslav; Snizhko, Kyrylo; Gefen, Yuval
2018-06-01
We consider charge pumping in a system of parafermions, implemented at fractional quantum Hall edges. Our pumping protocol leads to a noisy behavior of the pumped current. As the adiabatic limit is approached, not only does the noisy behavior persist but the counting statistics of the pumped current becomes robust and universal. In particular, the resulting Fano factor is given in terms of the system's topological degeneracy and the pumped quasiparticle charge. Our results are also applicable to the more conventional Majorana fermions.
Semisupervised learning using Bayesian interpretation: application to LS-SVM.
Adankon, Mathias M; Cheriet, Mohamed; Biem, Alain
2011-04-01
Bayesian reasoning provides an ideal basis for representing and manipulating uncertain knowledge, with the result that many interesting algorithms in machine learning are based on Bayesian inference. In this paper, we use the Bayesian approach with one and two levels of inference to model the semisupervised learning problem and give its application to the successful kernel classifier support vector machine (SVM) and its variant least-squares SVM (LS-SVM). Taking advantage of Bayesian interpretation of LS-SVM, we develop a semisupervised learning algorithm for Bayesian LS-SVM using our approach based on two levels of inference. Experimental results on both artificial and real pattern recognition problems show the utility of our method.
ERIC Educational Resources Information Center
Hakulinen, Erkki
1974-01-01
A survey at the Karolinska Institutet Bibliotek in Sweden, and a comparison with an earlier survey at the National Lending Library, showed that conventional bibliographical information media are still responsible for the major part of information about biomedical literature. (Author/LS)
A Land System representation for global assessments and land-use modeling.
van Asselen, Sanneke; Verburg, Peter H
2012-10-01
Current global scale land-change models used for integrated assessments and climate modeling are based on classifications of land cover. However, land-use management intensity and livestock keeping are also important aspects of land use, and are an integrated part of land systems. This article aims to classify, map, and to characterize Land Systems (LS) at a global scale and analyze the spatial determinants of these systems. Besides proposing such a classification, the article tests if global assessments can be based on globally uniform allocation rules. Land cover, livestock, and agricultural intensity data are used to map LS using a hierarchical classification method. Logistic regressions are used to analyze variation in spatial determinants of LS. The analysis of the spatial determinants of LS indicates strong associations between LS and a range of socioeconomic and biophysical indicators of human-environment interactions. The set of identified spatial determinants of a LS differs among regions and scales, especially for (mosaic) cropland systems, grassland systems with livestock, and settlements. (Semi-)Natural LS have more similar spatial determinants across regions and scales. Using LS in global models is expected to result in a more accurate representation of land use capturing important aspects of land systems and land architecture: the variation in land cover and the link between land-use intensity and landscape composition. Because the set of most important spatial determinants of LS varies among regions and scales, land-change models that include the human drivers of land change are best parameterized at sub-global level, where similar biophysical, socioeconomic and cultural conditions prevail in the specific regions. © 2012 Blackwell Publishing Ltd.
Designing a Broadband Pump for High-Quality Micro-Lasers via Modified Net Radiation Method.
Nechayev, Sergey; Reusswig, Philip D; Baldo, Marc A; Rotschild, Carmel
2016-12-07
High-quality micro-lasers are key ingredients in non-linear optics, communication, sensing and low-threshold solar-pumped lasers. However, such micro-lasers exhibit negligible absorption of free-space broadband pump light. Recently, this limitation was lifted by cascade energy transfer, in which the absorption and quality factor are modulated with wavelength, enabling non-resonant pumping of high-quality micro-lasers and solar-pumped laser to operate at record low solar concentration. Here, we present a generic theoretical framework for modeling the absorption, emission and energy transfer of incoherent radiation between cascade sensitizer and laser gain media. Our model is based on linear equations of the modified net radiation method and is therefore robust, fast converging and has low complexity. We apply this formalism to compute the optimal parameters of low-threshold solar-pumped lasers. It is revealed that the interplay between the absorption and self-absorption of such lasers defines the optimal pump absorption below the maximal value, which is in contrast to conventional lasers for which full pump absorption is desired. Numerical results are compared to experimental data on a sensitized Nd 3+ :YAG cavity, and quantitative agreement with theoretical models is found. Our work modularizes the gain and sensitizing components and paves the way for the optimal design of broadband-pumped high-quality micro-lasers and efficient solar-pumped lasers.
Designing a Broadband Pump for High-Quality Micro-Lasers via Modified Net Radiation Method
Nechayev, Sergey; Reusswig, Philip D.; Baldo, Marc A.; Rotschild, Carmel
2016-01-01
High-quality micro-lasers are key ingredients in non-linear optics, communication, sensing and low-threshold solar-pumped lasers. However, such micro-lasers exhibit negligible absorption of free-space broadband pump light. Recently, this limitation was lifted by cascade energy transfer, in which the absorption and quality factor are modulated with wavelength, enabling non-resonant pumping of high-quality micro-lasers and solar-pumped laser to operate at record low solar concentration. Here, we present a generic theoretical framework for modeling the absorption, emission and energy transfer of incoherent radiation between cascade sensitizer and laser gain media. Our model is based on linear equations of the modified net radiation method and is therefore robust, fast converging and has low complexity. We apply this formalism to compute the optimal parameters of low-threshold solar-pumped lasers. It is revealed that the interplay between the absorption and self-absorption of such lasers defines the optimal pump absorption below the maximal value, which is in contrast to conventional lasers for which full pump absorption is desired. Numerical results are compared to experimental data on a sensitized Nd3+:YAG cavity, and quantitative agreement with theoretical models is found. Our work modularizes the gain and sensitizing components and paves the way for the optimal design of broadband-pumped high-quality micro-lasers and efficient solar-pumped lasers. PMID:27924844
[Identification of Pummelo Cultivars Based on Hyperspectral Imaging Technology].
Li, Xun-lan; Yi, Shi-lai; He, Shao-lan; Lü, Qiang; Xie, Rang-jin; Zheng, Yong-qiang; Deng, Lie
2015-09-01
Existing methods for the identification of pummelo cultivars are usually time-consuming and costly, and are therefore inconvenient to be used in cases that a rapid identification is needed. This research was aimed at identifying different pummelo cultivars by hyperspectral imaging technology which can achieve a rapid and highly sensitive measurement. A total of 240 leaf samples, 60 for each of the four cultivars were investigated. Samples were divided into two groups such as calibration set (48 samples of each cultivar) and validation set (12 samples of each cultivar) by a Kennard-Stone-based algorithm. Hyperspectral images of both adaxial and abaxial surfaces of each leaf were obtained, and were segmented into a region of interest (ROI) using a simple threshold. Spectra of leaf samples were extracted from ROI. To remove the absolute noises of the spectra, only the date of spectral range 400~1000 nm was used for analysis. Multiplicative scatter correction (MSC) and standard normal variable (SNV) were utilized for data preprocessing. Principal component analysis (PCA) was used to extract the best principal components, and successive projections algorithm (SPA) was used to extract the effective wavelengths. Least squares support vector machine (LS-SVM) was used to obtain the discrimination model of the four different pummelo cultivars. To find out the optimal values of σ2 and γ which were important parameters in LS-SVM modeling, Grid-search technique and Cross-Validation were applied. The first 10 and 11 principal components were extracted by PCA for the hyperspectral data of adaxial surface and abaxial surface, respectively. There were 31 and 21 effective wavelengths selected by SPA based on the hyperspectral data of adaxial surface and abaxial surface, respectively. The best principal components and the effective wavelengths were used as inputs of LS-SVM models, and then the PCA-LS-SVM model and the SPA-LS-SVM model were built. The results showed that 99.46% and 98.44% of identification accuracy was achieved in the calibration set for the PCA-LS-SVM model and the SPA-LS-SVM model, respectively, and a 95.83% of identification accuracy was achieved in the validation set for both the PCA-LS-SVM and the SPA- LS-SVM models, which were built based on the hyperspectral data of adaxial surface. Comparatively, the results of the PCA-LS-SVM and the SPA-LS-SVM models built based on the hyperspectral data of abaxial surface both achieved identification accuracies of 100% for both calibration set and validation set. The overall results demonstrated that use of hyperspectral data of adaxial and abaxial leaf surfaces coupled with the use of PCA-LS-SVM and the SPA-LS-SVM could achieve an accurate identification of pummelo cultivars. It was feasible to use hyperspectral imaging technology to identify different pummelo cultivars, and hyperspectral imaging technology provided an alternate way of rapid identification of pummelo cultivars. Moreover, the results in this paper demonstrated that the data from the abaxial surface of leaf was more sensitive in identifying pummelo cultivars. This study provided a new method for to the fast discrimination of pummelo cultivars.
Kaleli, Necati; Saraç, Duygu
2017-07-01
Most studies evaluating dental laser sintering systems have focused on the marginal accuracy of the restorations. However, the bond strength at the metal-ceramic interface is another important factor that affects the survival of restorations, and currently, few studies focus on this aspect. The purpose of this in vitro study was to compare the porcelain bond strength of cobalt-chromium (Co-Cr) metal frameworks prepared by using the conventional lost-wax technique, milling, direct metal laser sintering (DMLS), and laser cusing, a direct process powder-bed system. A total of 96 metal frameworks (n=24 in each group) were prepared by using conventional lost-wax (group C), milling (group M), DMLS (group LS), and direct process powder-bed (group LC) methods according to International Organization for Standardization standard ISO 9693-1. After porcelain application, a 3-point bend test was applied to each specimen by using a universal testing machine. Data were statistically analyzed using 1-way ANOVA and Tukey honest significant difference tests (α=.05). Failure types at the metal-ceramic interfaces were examined using stereomicroscopy. Additionally, 1 specimen from each group was prepared for scanning electron microscopy analysis to evaluate the surface topography of metal frameworks. The mean bond strength was 38.08 ±3.82 MPa for group C, 39.29 ±3.51 MPa for group M, 40.73 ±3.58 MPa for group LS, and 41.24 ±3.75 MPa for group LC. Statistically significant differences were observed among the 4 groups (P=.016). All groups, except for LS, exhibited adhesive and mixed type bond failure. Both of the laser sintering methods were found to be successful in terms of metal-ceramic bond strength. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
A threshold-based fixed predictor for JPEG-LS image compression
NASA Astrophysics Data System (ADS)
Deng, Lihua; Huang, Zhenghua; Yao, Shoukui
2018-03-01
In JPEG-LS, fixed predictor based on median edge detector (MED) only detect horizontal and vertical edges, and thus produces large prediction errors in the locality of diagonal edges. In this paper, we propose a threshold-based edge detection scheme for the fixed predictor. The proposed scheme can detect not only the horizontal and vertical edges, but also diagonal edges. For some certain thresholds, the proposed scheme can be simplified to other existing schemes. So, it can also be regarded as the integration of these existing schemes. For a suitable threshold, the accuracy of horizontal and vertical edges detection is higher than the existing median edge detection in JPEG-LS. Thus, the proposed fixed predictor outperforms the existing JPEG-LS predictors for all images tested, while the complexity of the overall algorithm is maintained at a similar level.
Leigh syndrome: neuropathology and pathogenesis.
Lake, Nicole J; Bird, Matthew J; Isohanni, Pirjo; Paetau, Anders
2015-06-01
Leigh syndrome (LS) is the most common pediatric presentation of a defined mitochondrial disease. This progressive encephalopathy is characterized pathologically by the development of bilateral symmetrical lesions in the brainstem and basal ganglia that show gliosis, vacuolation, capillary proliferation, relative neuronal preservation, and by hyperlacticacidemia in the blood and/or cerebrospinal fluid. Understanding the molecular mechanisms underlying this unique pathology has been challenging, particularly in view of the heterogeneous and not yet fully determined genetic basis of LS. Moreover, animal models that mimic features of LS have only been created relatively recently. Here, we review the pathology of LS and consider what might be the molecular mechanisms underlying its pathogenesis. Data from a wide range of sources, including patient samples, animal models, and studies of hypoxic-ischemic encephalopathy (a condition that shares features with LS), were used to provide insight into the pathogenic mechanisms that may drive lesion development. Based on current data, we suggest that severe ATP depletion, gliosis, hyperlacticacidemia, reactive oxygen species, and potentially excitotoxicity cumulatively contribute to the neuropathogenesis of LS. An intimate understanding of the molecular mechanisms causing LS is required to accelerate the development of LS treatments.
Nicholson, K M; Phillips, R M; Shnyder, S D; Bibby, M C
2002-01-01
LS 4477 and LS 4559, two of a series of N-acyl-aminoalkyl phenyl ethers, are rationally designed compounds based on the tubulin binder estramustine. This study investigated their mechanism of action and compared their effectiveness in relation to estramustine in vitro against a panel of human and murine cell lines and in vivo against two murine colon tumour models (MAC). At biologically relevant concentrations, LS 4477 and LS 4559 caused a 59.9 and 56% reduction in tubulin assembly, respectively, compared with a 28.4% reduction in tubulin assembly by estramustine. The analogues were approximately 100 times more potent in chemosensitivity tests in vitro than the parent compound. Both analogues were orally active against the MAC 15A murine tumour model, to a greater extent than estramustine, producing significant growth delays (P<0.01). Significant activity was also shown against the slower growing MAC 26 tumour for LS 4577 (the soluble pro-drug of LS 4559). The results presented in this study suggest these compounds warrant further development with a view to assessing their clinical activity.
NASA Astrophysics Data System (ADS)
Slovacek, A. E.; Fisher, A. T.; Kirkwood, W.; Wheat, C. G.; Maughan, T.; Gomes, K.
2011-12-01
We developed an autonomous electromagnetic flowmeter as part of a cross-hole hydrogeologic experiment using subseafloor borehole observatories (CORKs) that penetrate into the volcanic ocean crust. The cylindrical flowmeter is adapted from a conventional industrial tool and hardened for use at water depths up to 6000 m. In addition, the electronics were modified with a new power controller, and a data logger and communication board was added to enable data storage and long-term, autonomous use for up to eight years. The flowmeter generates a magnetic field and measures a voltage gradient that is created across the orifice as water moves through it. This kind of tool is ideally suited for use in the deep sea, particularly for measuring hydrothermal fluids emanating from the ocean crust, because it requires no moving parts, places no obstructions along the flow path, gives total flow volume as well as instantaneous flow rate, and is highly accurate across a large dynamic range, including bi-directional flow. This flowmeter was deployed on a CORK wellhead using an adapter and ring clamp system located above a 4-inch ball valve. The ball valve can be opened to permit flow (from an overpressured formation) out of the CORK and into the overlying ocean. A polyvinyl chloride "chimney" positioned vertically above the flowmeter is instrumented with autonomous temperature loggers to permit an additional estimate of fluid flow rates with time, based on heat loss during fluid ascent, and to facilitate fluid sampling. Calibration of the new flowmeter was completed in two stages: tank testing using a pump at flow rates of 0.5 to 1.2 L/s, and by lowering the flowmeter on a wireline at sea at rates equivalent to 0.5 to 5.2 L/s. A cross plot of apparent and reference flow rates obtained during calibration indicates a highly linear instrument response. Comparison of instantaneous (once per minute) and integrated (total flow) data collected during calibration indicates good agreement, although the instantaneous data tended to be noisy because of irregularity of flow (turbulence). The flowmeter was deployed in Summer 2011 on a CORK installed in IODP Hole 1362B, on the eastern flank of the Juan de Fuca ridge. Once the flowmeter was attached to the wellhead, the underlying ball valve was opened, which allowed overpressured fluids from the permeable ocean crust to flow upward and out of the seafloor at 5 to 10 L/s (estimated rate). Changes in formation fluid pressure resulting from this flow are being monitored in four additional CORKs located 310 to 2320 m away from Hole 1362B, which will allow large-scale, directional assessment of formation properties. The flowmeter is recording data for instantaneous flow rate and total flow once per hour, and will be recovered to permit collection and analysis of experimental data during a servicing visit in Summer 2012.
DOE Office of Scientific and Technical Information (OSTI.GOV)
May, E. K.; Forristall, R.
2005-11-01
Industrial Solar Technology has assembled a team of experts to develop a large-aperture parabolic trough for the electric power market that moves beyond cost and operating limitations of 1980's designs based on sagged glass reflectors. IST's structurally efficient space frame design will require nearly 50% less material per square meter than a Solel LS-2 concentrator and the new trough will rotate around the focal point. This feature eliminates flexhoses that increase pump power, installation and maintenance costs. IST aims to deliver a concentrator module costing less than $100 per square meter that can produce temperatures up to 400 C. Themore » IST concentrator is ideally suited for application of front surface film reflectors and ensures that US corporations will manufacture major components, except for the high temperature receivers.« less
a Highly-Integrated Supersonic-Jet Fourier Transform Microwave Spectrometer
NASA Astrophysics Data System (ADS)
Gou, Qian; Feng, Gang; Grabow, Jens-Uwe
2017-06-01
A highly integrated supersonic-jet Fourier-transform microwave spectrometer of coaxially oriented beam-resonator arrangement (COBRA) type, covering 2-20GHz, has been recently built at Chongqing University, China. Built up almost entirely in an NI PXIe chassis, we take the advantage of the NI PXIe-5451 Dual-channel arbitrary waveform generator and the PXIe-5654 RF signal generator to create a spectrometer with wobbling capacity for fast resonator tuning. Based on the I/Q modulation, associate with PXI control and sequence boards built at the Leibniz Universitat Hannover, the design of the spectrometer is much simpler and very compact. The Fabry-Pérot resonator is semi-confocal with a spherical reflector of 630 mm diameter and a radius of 900 mm curvature and one circulator plate reflector of 630 mm diameter. The vacuum is effectuated by a three-stage mechanical (two-stage rotary vane and roots booster) pump at the fore line of a DN630 ISO-F 20000 L/s oil-diffusion pump. The supersonic-jet expansion is pulsed by a general valve Series 9 solenoid valve which is controlled by a general valve IOTA one driver governed by the experiment-sequence generation. First molecular examples to illustrate the performance of the new setup will include OCS and CF_3CHFCl.
NASA Astrophysics Data System (ADS)
Cashen, M.; Yatsenko, L.; Metcalf, H.
2001-05-01
Sisyphus cooling arises when the conservative dipole force of a monochromatic optical standing wave (SW) is modified by optical pumping among multiple ground state sublevels at low intensity(J. Dalibard and C. Cohen-Tannoudji, J. Opt. Soc. B6), 2023 (1989)., or among dressed state manifolds at high intensity(A. Aspect et al., Phys. Rev. Lett. 57), 1688 (1986). As part of our ongoing exploration of optical forces in non-monochromatic light, we have discovered a new type of Sisyphus cooling in a two-level atom where the optical pumping is driven by a second SW produced as a sideband from weak frequency modulation. Each beam of the carrier's SW has a Rabi frequency Ωc ~ 20 γ and is tuned below atomic resonance by δc ~ -38 γ. Thus the light shift at the antinodes is ω_c^ls ~ 8.6 γ. For the sideband, Ωs ~ 1.4 γ and δs ~ +1 γ so ω_s^ls ~ 1 γ. The resulting forces satisfy Fc > 8 F_s. By contrast, the excitation rate γ_s^p > 2 γ_c^p. We choose the relative spatial phase of the SW's to be π, so moving atoms are most likely to be excited at the red-tuned carrier nodes, and thus they climb more hills than they descend. We observe transverse cooling of a beam of He metastables when δc < 0 and heating otherwise, in contrast to Ref. 3 because here the excitation is at the nodes of the high intensity carrier SW. We also observe channeling of the slow atoms in the carrier's SW.
Yellapu, Sravan Kumar; Kaur, Rajwinder; Tyagi, Rajeshwar D
2017-01-01
In situ transesterification of oleaginous yeast wet biomass for fatty acid methyl esters (FAMEs) production using acid catalyst, methanol with or without N-Lauroyl sarcosine (N-LS) treatment was performed. The maximum FAMEs yield obtained with or without N-LS treatment in 24h reaction time was 96.1±1.9 and 71±1.4% w/w, respectively. The N-LS treatment of biomass followed by with or without ultrasonication revealed maximum FAMEs yield of 94.3±1.9% and 82.9±1.8% w/w using methanol to lipid molar ratio 360:1 and catalyst concentration 360mM (64μL H 2 SO 4 /g lipid) within 5 and 25min reaction time, respectively. The FAMEs composition obtained in in situ transesterification was similar to that obtained with conventional two step lipid extraction and transesterification process. Biodiesel fuel properties (density, kinematic viscosity, cetane number and total glycerol) were in accordance with international standard (ASTM D6751), which suggests the suitability of biodiesel as a fuel. Copyright © 2016 Elsevier Ltd. All rights reserved.
Yellapu, Sravan Kumar; Bezawada, Jyothi; Kaur, Rajwinder; Kuttiraja, Mathiazhakan; Tyagi, Rajeshwar D
2016-10-01
The lipid extraction from the microbial biomass is a tedious and high cost dependent process. In the present study, detergent assisted lipids extraction from the culture of the yeast Yarrowia lipolytica SKY-7 was carried out. Response surface methodology (RSM) was used to investigate the effect of three principle parameters (N-LS concentration, time and temperature) on microbial lipid extraction efficiency % (w/w). The results obtained by statistical analysis showed that the quadratic model fits in all cases. Maximum lipid recovery of 95.3±0.3% w/w was obtained at the optimum level of process variables [N-LS concentration 24.42mg (equal to 48mgN-LS/g dry biomass), treatment time 8.8min and reaction temperature 30.2°C]. Whereas the conventional chloroform and methanol extraction to achieve total lipid recovery required 12h at 60°C. The study confirmed that oleaginous yeast biomass treatment with N-lauroyl sarcosine would be a promising approach for industrial scale microbial lipid recovery. Copyright © 2016 Elsevier Ltd. All rights reserved.
Evaluation and proposed study of potential ground-water supplies, Gallup area, New Mexico
Hiss, William L.
1975-01-01
The ground-water potential of 5 areas in central-western New Mexico within 85 miles (135 km) of Gallup, N. Mex. was evaluated by reviewing the published literature, inspecting aerial and space photographs, and interviewing ranchers and personnel employed by well-drilling and mineral-exploration companies by telephone. The San Andres Limestone and underlying Glorieta Sandstone of Permian age are the oldest aquifers capable of yielding water of a quality suitable for municipal use. Extreme local variations in hydraulic conductivity and water quality reflect a karstic topography developed on the San Andres Limestone prior to burial by Upper Triassic sediments. The San Andres Limestone and Glorieta Sandstone form an important aquifer in the Grants-Bluewater area where yields of as much as 2,200 gallons per minute (140 l/s) have been obtained. Yields from wells completed in the San Andres-Glorieta aquifer on the Chaco slope and in the Gallup sag-Mogollon slope on the northeast and southeast flanks, respectively, of the Zuni uplift will be much less than those prevailing in the Grants-Bluewater area. Water quality in the San Andres Limestone and Glorieta Sandstone deteriorates with distance away from the axis of the Zuni uplift. Sandstones of Triassic, Jurassic, and Cretaceous age are potential aquifers wherever they are present. Yields to wells tapping these aquifers are generally less than 200 gallons per minute (13 l/s) due to the relatively low hydraulic conductivity. Wells tapping alluvium of Late Cenozoic age along the Rio San Jose and Puerco River and interbedded volcanics and alluvium elsewhere in the area generally yield less than 100 gallons per minute (6 l/s) of water. Tributaries ,of the Rio San Jose that have eroded canyons into Paleozoic and Mesozoic rocks east of the Continental Divide and south of the eastern part of the Zuni uplift have been repeatedly displaced and (or) covered by Quaternary volcanic rocks. The exact location, extent, and depth of buried alluvium in the Late Tertiary valleys is unknown. Water enters the volcanic rocks as rainfall and snowmelt and probably passes quickly into and through, the underlying alluvium into Jurassic and Cretaceous strata. The Gallup Sandstone in the lower part of the Mesaverde Group and the San Andres Limestone and Glorieta Sandstone (combined) are potential sources of water in the North Plains-Malpais area. Sustained yields of 500 to 800 gallons per minute (30 to 50 l/s) can be expected from wells completed in the Gallup Sandstone of Cretaceous age in areas west and north of the Zuni uplift. Properly completed wells tapping the Dakota Sandstone of Cretaceous age and the Westwater Canyon Sandstone Member of the Morrison Formation of Jurassic age locally yield 100 to 250 gallons per minute (6 to 15 l/s) north and east of Gallup. Additional supplies of ground water could be developed from these aquifers. However, arrangements to purchase or lease the water would probably need to be made before these resources could be exploited. Approximately 3,000 gallons per minute (190 l/s) of ground water is being pumped from the Westwater Canyon Member of the Morrison Formation at two uranium mines located about 12 miles (20 km) northeast of Gallup in the Church Rock mining district. The water is pumped into settling ponds at the surface. Effluent from the ponds is allowed to flow into arroyos draining into the Puerco River. Some of the waste water will be used in an ore-processing mill that is expected to be constructed near the mines. However, additional waste water will probably be available from other mines that reportedly will be located in the same mining district. Water salvaged from the current mining operations and (or) pumped from abandoned uranium mines constitutes the most readily available and dependable source of new ground-water supplies for the city of Gallup. The water contains dissolved uranium but is otherwise of better quality than that now avai
NASA Astrophysics Data System (ADS)
DSouza, Adora M.; Abidin, Anas Z.; Leistritz, Lutz; Wismüller, Axel
2017-02-01
We investigate the applicability of large-scale Granger Causality (lsGC) for extracting a measure of multivariate information flow between pairs of regional brain activities from resting-state functional MRI (fMRI) and test the effectiveness of these measures for predicting a disease state. Such pairwise multivariate measures of interaction provide high-dimensional representations of connectivity profiles for each subject and are used in a machine learning task to distinguish between healthy controls and individuals presenting with symptoms of HIV Associated Neurocognitive Disorder (HAND). Cognitive impairment in several domains can occur as a result of HIV infection of the central nervous system. The current paradigm for assessing such impairment is through neuropsychological testing. With fMRI data analysis, we aim at non-invasively capturing differences in brain connectivity patterns between healthy subjects and subjects presenting with symptoms of HAND. To classify the extracted interaction patterns among brain regions, we use a prototype-based learning algorithm called Generalized Matrix Learning Vector Quantization (GMLVQ). Our approach to characterize connectivity using lsGC followed by GMLVQ for subsequent classification yields good prediction results with an accuracy of 87% and an area under the ROC curve (AUC) of up to 0.90. We obtain a statistically significant improvement (p<0.01) over a conventional Granger causality approach (accuracy = 0.76, AUC = 0.74). High accuracy and AUC values using our multivariate method to connectivity analysis suggests that our approach is able to better capture changes in interaction patterns between different brain regions when compared to conventional Granger causality analysis known from the literature.
Predictive Trip Detection for Nuclear Power Plants
NASA Astrophysics Data System (ADS)
Rankin, Drew J.; Jiang, Jin
2016-08-01
This paper investigates the use of a Kalman filter (KF) to predict, within the shutdown system (SDS) of a nuclear power plant (NPP), whether safety parameter measurements have reached a trip set-point. In addition, least squares (LS) estimation compensates for prediction error due to system-model mismatch. The motivation behind predictive shutdown is to reduce the amount of time between the occurrence of a fault or failure and the time of trip detection, referred to as time-to-trip. These reductions in time-to-trip can ultimately lead to increases in safety and productivity margins. The proposed predictive SDS differs from conventional SDSs in that it compares point-predictions of the measurements, rather than sensor measurements, against trip set-points. The predictive SDS is validated through simulation and experiments for the steam generator water level safety parameter. Performance of the proposed predictive SDS is compared against benchmark conventional SDS with respect to time-to-trip. In addition, this paper analyzes: prediction uncertainty, as well as; the conditions under which it is possible to achieve reduced time-to-trip. Simulation results demonstrate that on average the predictive SDS reduces time-to-trip by an amount of time equal to the length of the prediction horizon and that the distribution of times-to-trip is approximately Gaussian. Experimental results reveal that a reduced time-to-trip can be achieved in a real-world system with unknown system-model mismatch and that the predictive SDS can be implemented with a scan time of under 100ms. Thus, this paper is a proof of concept for KF/LS-based predictive trip detection.
Preparation of Gd Loaded Liquid Scintillator for Daya Bay Neutrino Experiment
NASA Astrophysics Data System (ADS)
Ya-yun, Ding; Zhi-yong, Zhang
2010-05-01
Gadolinium loaded liquid scintillator (Gd-LS) is an excellent target material for reactor antineutrino experiments. Ideal Gd-LS should have long attenuation length, high light yield, long term stability, low toxicity, and should be compatible with the material used to build the detector. We have developed a new Gd-LS recipe in which carboxylic acid 3,5,5-trimethylhexanoic acid is used as the complexing ligand to gadolinium, 2,5-diphenyloxazole (PPO) and 1,4-bis[2-methylstyryl]benzene (bis-MSB) are used as primary fluor and wavelength shifter, respectively. The scintillator base is linear alkyl benzene (LAB). Eight hundred liters of Gd-LS has been synthesized and tested in a prototype detector. Results show that the Gd-LS has high quality and is suitable for underground experiments in large quantity. Large scale production facility has been built. A full batch production of 4 t Gd-LS has been produced and monitored for several months. The production of 180 t Gd-LS will be carried out in the near future.
A Modified LS+AR Model to Improve the Accuracy of the Short-term Polar Motion Prediction
NASA Astrophysics Data System (ADS)
Wang, Z. W.; Wang, Q. X.; Ding, Y. Q.; Zhang, J. J.; Liu, S. S.
2017-03-01
There are two problems of the LS (Least Squares)+AR (AutoRegressive) model in polar motion forecast: the inner residual value of LS fitting is reasonable, but the residual value of LS extrapolation is poor; and the LS fitting residual sequence is non-linear. It is unsuitable to establish an AR model for the residual sequence to be forecasted, based on the residual sequence before forecast epoch. In this paper, we make solution to those two problems with two steps. First, restrictions are added to the two endpoints of LS fitting data to fix them on the LS fitting curve. Therefore, the fitting values next to the two endpoints are very close to the observation values. Secondly, we select the interpolation residual sequence of an inward LS fitting curve, which has a similar variation trend as the LS extrapolation residual sequence, as the modeling object of AR for the residual forecast. Calculation examples show that this solution can effectively improve the short-term polar motion prediction accuracy by the LS+AR model. In addition, the comparison results of the forecast models of RLS (Robustified Least Squares)+AR, RLS+ARIMA (AutoRegressive Integrated Moving Average), and LS+ANN (Artificial Neural Network) confirm the feasibility and effectiveness of the solution for the polar motion forecast. The results, especially for the polar motion forecast in the 1-10 days, show that the forecast accuracy of the proposed model can reach the world level.
Superficial photoluminescence and PV conversion of nanoscale Si-layered systems at 400 nm
NASA Astrophysics Data System (ADS)
Kuznicki, Zbigniew T.; Meyrueis, Patrick; Sarrabayrouse, Gérard; Rousset, Bernard
2006-04-01
A surprising photovoltaic (PV) conversion at 400 nm has been observed in nanoscale Si-layered systems (ns-Si-ls) during spectral response measurements. In conventional solar cells the UV and blue PV conversion may be poor because of the surface recombination within a thin superficial layer. In multi-interface novel devices (MIND) containing ns-Si-ls this conversion is always negligible within an even thicker surface dead zone from which practically no free-carriers can be collected. So the measured 400 nm band PV conversion in MIND cells is totally inconsistent with usually observed effects. Another CE paradox concerns its inversely proportional variation versus incident flux intensity, lower the intensity higher the CE, which value can even exceed unity. This new effect is also localized at the superficial nanostratum and originates from postimplantation defects and nanostructures formed during the implantation process. A similar low energy free-carrier generation has been observed recently in MIND cells with buried ns-Si-ls having a relatively very thin superficial stratum because of an excellent electronic passivation. No available publication mentions such an effect despite extensive investigations on the subject of structural and optical properties of Si nanoparticles, Si nanolayers, new Si-based materials such as semiconductor silicides and the luminescence-center doped Si materials. In this work, the carrier collection properties of the superficial Si nanostratum are reported and discussed in detail in relation to incident flux intensity. An additional low energy generation was observed experimentally. The effect could have capital importance for a breakthrough in the PV conversion efficiency in Si solar cells with nanotransformations.
Ng, Zi Jia; E Huebner, Scott; J Hills, Kimberly
2015-12-01
Student subjective well-being remains a relatively neglected topic despite its intimate link to positive school outcomes. As academic achievement is a widely used yardstick of student success and school accountability, school-based mental health research and practice have focused primarily on the assessment and treatment of learning and behavioral problems. This short-term longitudinal study sought to establish the role of student subjective well-being, specifically, global life satisfaction (LS), in academic achievement. Based on the engine model of well-being (Jayawickreme, Forgeard, & Seligman, 2012), the study focused on LS as a process variable and academic performance as an outcome variable and vice versa. Using two waves (five months apart) of data, the study examined the reciprocal relations between LS and academic achievement, and how the relations may be shaped by positive and negative affective experiences in school, in a sample of 821 middle school students. Results revealed positive reciprocal causal relations between students' LS and grades, even when demographic covariates, school-based positive and negative affect, and baseline values of the criterion variables were controlled. This study provides empirical support that LS does not undermine academic achievement (or vice versa), but rather it is synergistic with better school grades. Furthermore, the relations between students' LS and grades were not moderated by negative or positive affective experiences in school. These findings suggest that student LS should occupy a more prominent niche in the school agenda. Copyright © 2015 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.
Cheng, Shu-Xi; Xie, Chuan-Qi; Wang, Qiao-Nan; He, Yong; Shao, Yong-Ni
2014-05-01
Identification of early blight on tomato leaves by using hyperspectral imaging technique based on different effective wavelengths selection methods (successive projections algorithm, SPA; x-loading weights, x-LW; gram-schmidt orthogonaliza-tion, GSO) was studied in the present paper. Hyperspectral images of seventy healthy and seventy infected tomato leaves were obtained by hyperspectral imaging system across the wavelength range of 380-1023 nm. Reflectance of all pixels in region of interest (ROI) was extracted by ENVI 4. 7 software. Least squares-support vector machine (LS-SVM) model was established based on the full spectral wavelengths. It obtained an excellent result with the highest identification accuracy (100%) in both calibration and prediction sets. Then, EW-LS-SVM and EW-LDA models were established based on the selected wavelengths suggested by SPA, x-LW and GSO, respectively. The results showed that all of the EW-LS-SVM and EW-LDA models performed well with the identification accuracy of 100% in EW-LS-SVM model and 100%, 100% and 97. 83% in EW-LDA model, respectively. Moreover, the number of input wavelengths of SPA-LS-SVM, x-LW-LS-SVM and GSO-LS-SVM models were four (492, 550, 633 and 680 nm), three (631, 719 and 747 nm) and two (533 and 657 nm), respectively. Fewer input variables were beneficial for the development of identification instrument. It demonstrated that it is feasible to identify early blight on tomato leaves by using hyperspectral imaging, and SPA, x-LW and GSO were effective wavelengths selection methods.
Off-pump coronary artery bypass surgery in severe left ventricular dysfunction.
Azarfarin, Rasoul; Pourafkari, Leili; Parvizi, Rezayat; Alizadehasl, Azin; Mahmoodian, Roghaiyeh
2010-02-01
Our aim was to examine hospital outcomes of coronary artery bypass surgery in patients with and without left ventricular dysfunction, with regard to the surgical technique (off- or on-pump). Between March 2007 and March 2008, 689 consecutive patients underwent isolated first-time coronary artery bypass; 127 had ejection fractions < or = 30% (group 1) and 562 had ejection fractions >30% (group 2). Data of preoperative risk profiles and hospital outcomes were collected prospectively. Off-pump operations were performed in 49 (38.6%) patients in group 1 and 196 (34.9%) in group 2. The incidences of infectious, neurologic, and cardiac complications postoperatively were significantly higher in group 1. In multivariate analysis, preoperative ejection fraction < or = 30% was found to be an independent risk factor for postoperative complications and hospital mortality. The subgroup of patients undergoing off-pump surgery in both groups had a significantly lower rate of total complications than those undergoing conventional on-pump operations, but no significant difference in mortality was observed between those undergoing off-pump or conventional surgery in either group. Off-pump surgery helped to limit the increased morbidity rate after coronary bypass in patients with ventricular dysfunction.
Acid mine treatment with open limestone channels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ziemkiewicz, P.F.; Brant, D.L.; Skousen, J.G.
1996-12-31
Acid mine drainage (AMD) is often associated with mining of pyritic coal and metal deposits. Typical AMD associated with coal mines in the eastern US can have acidity and iron concentrations ranging from the teens to the thousands of mg/l. Aluminum and manganese can be present in concentrations ranging from zero to the low hundreds of mg/l. Much attention has been devoted to developing inexpensive, limestone (LS)-based systems for treating AMID with little or no maintenance. However, LS tends to coat with metal hydroxides when exposed to AMID in an oxidized state, a process known as {open_quotes}armoring{close_quotes}. It is generallymore » assumed that once armored, LS ceases to neutralize acid. Another problem is that the hydroxides tend to settle into plug the pore spaces in LS beds forcing water to move around rather than through the LS. While both are caused by the precipitation of metal hydroxides, armoring and plugging are two different problems. Plugging of LS pores can be avoided by maintaining a high flushing rate through the LS bed. Armoring, however, occurs regardless of water velocity. This study investigated the influence of armoring on LS solubility and the implications of armoring and plugging on the construction of open (oxidizing) LS channels for treating AMD. We evaluated the AMID treatment performance of armored and unarmored LS in oxidizing environments both in laboratory and field studies.« less
Reduced-rank technique for joint channel estimation in TD-SCDMA systems
NASA Astrophysics Data System (ADS)
Kamil Marzook, Ali; Ismail, Alyani; Mohd Ali, Borhanuddin; Sali, Adawati; Khatun, Sabira
2013-02-01
In time division-synchronous code division multiple access systems, increasing the system capacity by exploiting the inserting of the largest number of users in one time slot (TS) requires adding more estimation processes to estimate the joint channel matrix for the whole system. The increase in the number of channel parameters due the increase in the number of users in one TS directly affects the precision of the estimator's performance. This article presents a novel channel estimation with low complexity, which relies on reducing the rank order of the total channel matrix H. The proposed method exploits the rank deficiency of H to reduce the number of parameters that characterise this matrix. The adopted reduced-rank technique is based on truncated singular value decomposition algorithm. The algorithms for reduced-rank joint channel estimation (JCE) are derived and compared against traditional full-rank JCEs: least squares (LS) or Steiner and enhanced (LS or MMSE) algorithms. Simulation results of the normalised mean square error showed the superiority of reduced-rank estimators. In addition, the channel impulse responses founded by reduced-rank estimator for all active users offers considerable performance improvement over the conventional estimator along the channel window length.
Performance improvement of long-range surface plasmon structure for use in an all-optical switch
NASA Astrophysics Data System (ADS)
Jandaghian, Ali; Lotfalian, Ali; Kouhkan, Mohsen; Mohajerani, Ezeddin
2017-12-01
This paper presents important parameters in performance of long-range surface plasmon (LRSP) structure (SF4/PVA/silver/PMMA-DR1) that are improved. We select poly(vinyl alcohol) (PVA) as the first dielectric layer due to its water solubility and good optical properties. The thickness of PVA and silver layers is optimized by transfer matrix method based on Fresnel equations. Surface morphologies of PVA and silver surfaces are analyzed by AFM imaging due to their important role in the performance of an LRSP structure. Furthermore, the sensitivity of an all-optical switch based on plasmon is investigated. In order to compare the sensitivity of LRSP and conventional surface plasmon (SP) structures in switching mode, full wide of half maximum, resonance angles, and pump powers of both structures are measured by a custom-made optical setup based on angular interrogation with a precision of 0.01 deg. Finally, we conclude that for creating equal signal levels in both samples, the required pump power for LRSP structure was about three times less than that for conventional SP; thus, these results led to power savings in optical switches.
Random lasing actions in self-assembled perovskite nanoparticles
NASA Astrophysics Data System (ADS)
Liu, Shuai; Sun, Wenzhao; Li, Jiankai; Gu, Zhiyuan; Wang, Kaiyang; Xiao, Shumin; Song, Qinghai
2016-05-01
Solution-based perovskite nanoparticles have been intensively studied in the past few years due to their applications in both photovoltaic and optoelectronic devices. Here, based on the common ground between solution-based perovskite and random lasers, we have studied the mirrorless lasing actions in self-assembled perovskite nanoparticles. After synthesis from a solution, discrete lasing peaks have been observed from optically pumped perovskites without any well-defined cavity boundaries. We have demonstrated that the origin of the random lasing emissions is the scattering between the nanostructures in the perovskite microplates. The obtained quality (Q) factors and thresholds of random lasers are around 500 and 60 μJ/cm2, respectively. Both values are comparable to the conventional perovskite microdisk lasers with polygon-shaped cavity boundaries. From the corresponding studies on laser spectra and fluorescence microscope images, the lasing actions are considered random lasers that are generated by strong multiple scattering in random gain media. In additional to conventional single-photon excitation, due to the strong nonlinear effects of perovskites, two-photon pumped random lasers have also been demonstrated for the first time. We believe this research will find its potential applications in low-cost coherent light sources and biomedical detection.
Vapor compression heat pump system field tests at the TECH complex
NASA Astrophysics Data System (ADS)
Baxter, V. D.
1985-07-01
The Tennessee Energy Conservation In Housing (TECH) complex has been utilized since 1977 as a field test site for several novel and conventional heat pump systems for space conditioning and water heating. Systems tested include the Annual Cycle Energy System (ACES), solar assisted heat pumps (SAHP) both parallel and series, two conventional air-to-air heat pumps, an air-to-air heat pump with desuperheater water heater, and horizontal coil and multiple shallow vertical coil ground-coupled heat pumps (GCHP). A direct comparison of the measured annual performance of the test systems was not possible. However, a cursory examination revealed that the ACES had the best performance. However, its high cost makes it unlikely that it will achieve widespread use. Costs for the SAHP systems are similar to those of the ACES but their performance is not as good. Integration of water heating and space conditioning functions with a desuperheater yielded significant efficiency improvement at modest cost. The GCHP systems performed much better for heating than for cooling and may well be the most efficient alternative for residences in cold climates.
Vapor compression heat pump system field tests at the tech complex
NASA Astrophysics Data System (ADS)
Baxter, Van D.
1985-11-01
The Tennessee Energy Conservation In Housing (TECH) complex has been utilized since 1977 as a field test site for several novel and conventional heat pump systems for space conditioning and water heating. Systems tested include the Annual Cycle Energy System (ACES), solar assisted heat pumps (SAHP) both parallel and series, two conventional air-to-air heat pumps, an air-to-air heat pump with desuperheater water heater, and horizontal coil and multiple shallow vertical coil ground-coupled heat pumps (GCHP). A direct comparison of the measured annual performance of the test systems was not possible. However, a cursory examination revealed that the ACES had the best performance, however, its high cost makes it unlikely that it will achieve wide-spread use. Costs for the SAHP systems are similar to those of the ACES but their performance is not as good. Integration of water heating and space conditioning functions with a desuperheater yielded significant efficiency improvement at modest cost. The GCHP systems performed much better for heating than for cooling and may well be the most efficient alternative for residences in cold climates.
Liu, Xue-song; Sun, Fen-fang; Jin, Ye; Wu, Yong-jiang; Gu, Zhi-xin; Zhu, Li; Yan, Dong-lan
2015-12-01
A novel method was developed for the rapid determination of multi-indicators in corni fructus by means of near infrared (NIR) spectroscopy. Particle swarm optimization (PSO) based least squares support vector machine was investigated to increase the levels of quality control. The calibration models of moisture, extractum, morroniside and loganin were established using the PSO-LS-SVM algorithm. The performance of PSO-LS-SVM models was compared with partial least squares regression (PLSR) and back propagation artificial neural network (BP-ANN). The calibration and validation results of PSO-LS-SVM were superior to both PLS and BP-ANN. For PSO-LS-SVM models, the correlation coefficients (r) of calibrations were all above 0.942. The optimal prediction results were also achieved by PSO-LS-SVM models with the RMSEP (root mean square error of prediction) and RSEP (relative standard errors of prediction) less than 1.176 and 15.5% respectively. The results suggest that PSO-LS-SVM algorithm has a good model performance and high prediction accuracy. NIR has a potential value for rapid determination of multi-indicators in Corni Fructus.
Evaluation of a large capacity heat pump concept for active cooling of hypersonic aircraft structure
NASA Technical Reports Server (NTRS)
Pagel, L. L.; Herring, R. L.
1978-01-01
Results of engineering analyses assessing the conceptual feasibility of a large capacity heat pump for enhancing active cooling of hypersonic aircraft structure are presented. A unique heat pump arrangement which permits cooling the structure of a Mach 6 transport to aluminum temperatures without the aid of thermal shielding is described. The selected concept is compatible with the use of conventional refrigerants, with Freon R-11 selected as the preferred refrigerant. Condenser temperatures were limited to levels compatible with the use of conventional refrigerants by incorporating a unique multipass condenser design, which extracts mechanical energy from the hydrogen fuel, prior to each subsequent pass through the condenser. Results show that it is technically feasible to use a large capacity heat pump in lieu of external shielding. Additional analyses are required to optimally apply this concept.
Intelligent query by humming system based on score level fusion of multiple classifiers
NASA Astrophysics Data System (ADS)
Pyo Nam, Gi; Thu Trang Luong, Thi; Ha Nam, Hyun; Ryoung Park, Kang; Park, Sung-Joo
2011-12-01
Recently, the necessity for content-based music retrieval that can return results even if a user does not know information such as the title or singer has increased. Query-by-humming (QBH) systems have been introduced to address this need, as they allow the user to simply hum snatches of the tune to find the right song. Even though there have been many studies on QBH, few have combined multiple classifiers based on various fusion methods. Here we propose a new QBH system based on the score level fusion of multiple classifiers. This research is novel in the following three respects: three local classifiers [quantized binary (QB) code-based linear scaling (LS), pitch-based dynamic time warping (DTW), and LS] are employed; local maximum and minimum point-based LS and pitch distribution feature-based LS are used as global classifiers; and the combination of local and global classifiers based on the score level fusion by the PRODUCT rule is used to achieve enhanced matching accuracy. Experimental results with the 2006 MIREX QBSH and 2009 MIR-QBSH corpus databases show that the performance of the proposed method is better than that of single classifier and other fusion methods.
NASA Astrophysics Data System (ADS)
Kohjiro, Satoshi; Kikuchi, Kenichi; Maezawa, Masaaki; Furuta, Tomofumi; Wakatsuki, Atsushi; Ito, Hiroshi; Shimizu, Naofumi; Nagatsuma, Tadao; Kado, Yuichi
2008-09-01
We have demonstrated that a superconductor-insulator-superconductor (SIS) mixer pumped by a photonic local oscillator (LO) covers the whole frequency range of 0.2-0.5THz. In the bandwidth of 74% of the center frequency, this single-band receiver exhibits noise temperature of TRX⩽20hf/kB, where h is Planck's constant, f is the frequency, and kB is Boltzmann's constant. Resultant TRX is almost equal to TRX of the identical SIS mixer pumped by three conventional frequency-multiplier-based LOs which share the 0.2-0.5THz band. This technique will contribute to simple, wide-band, and low-noise heterodyne receivers in the terahertz region.
Thermal management of high power space based systems
NASA Technical Reports Server (NTRS)
Hwangbo, H.; Mcever, W. S.
1985-01-01
Conventional techniques of using a portion of the spacecraft skin for radiation of waste heat will be inadequate for high powered payloads (50 to 100 kWe) due to the lack of sufficient area. A Shuttle type system using a pumped single phase fluid loop could be scaled up to higher power but this type of system would require excessive pump power and weight. A pumped two-phase heat transfer loop has a much lower pumping requirement due to the higher latent heat of vaporization of the fluid in comparison to the sensible heat it can absorb through a temperature change. Concepts for an evaporator and a condenser for a pumped two-phase system are described. The condenser uses capillary grooves and a separate pumped condensate return line to achieve high heat transfer coefficients and stable operation due to the separation of the vapor and liquid flows. The cold plate evaporator uses wicks to contain the liquid and transport it to the heated surface. It can also function as a condenser for warming components. Control concepts for the cold plate are discussed. Concepts for deployment or erection of large space radiators are also considered.
NASA Astrophysics Data System (ADS)
Misnasanti; Dien, C. A.; Azizah, F.
2018-03-01
This study is aimed to describe Lesson Study (LS) activity and its roles in the development of mathematics learning instruments based on Learning Trajectory (LT). This study is a narrative study of teacher’s experiences in joining LS activity. Data collecting in this study will use three methods such as observation, documentations, and deep interview. The collected data will be analyzed with Milles and Huberman’s model that consists of reduction, display, and verification. The study result shows that through LS activity, teachers know more about how students think. Teachers also can revise their mathematics learning instrument in the form of lesson plan. It means that LS activity is important to make a better learning instruments and focus on how student learn not on how teacher teach.
NASA Astrophysics Data System (ADS)
Kornienko, Vladimir V.; Kitaeva, Galiya Kh.; Sedlmeir, Florian; Leuchs, Gerd; Schwefel, Harald G. L.
2018-05-01
We study a calibration scheme for terahertz wave nonlinear-optical detectors based on spontaneous parametric down-conversion. Contrary to the usual low wavelength pump in the green, we report here on the observation of spontaneous parametric down-conversion originating from an in-growth poled lithium niobate crystal pumped with a continuous wave 50 mW, 795 nm diode laser system, phase-matched to a terahertz frequency idler wave. Such a system is more compact and allows for longer poling periods as well as lower losses in the crystal. Filtering the pump radiation by a rubidium-87 vapor cell allowed the frequency-angular spectra to be obtained down to ˜0.5 THz or ˜1 nm shift from the pump radiation line. The presence of an amplified spontaneous emission "pedestal" in the diode laser radiation spectrum significantly hampers the observation of spontaneous parametric down-conversion spectra, in contrast to conventional narrowband gas lasers. Benefits of switching to longer pump wavelengths are pointed out, such as collinear optical-terahertz phase-matching in bulk crystals.
Quality of colonoscopy in Lynch syndrome
Niv, Yaron; Moeslein, Gabriela; Vasen, Hans F.A.; Karner-Hanusch, Judith; Lubinsky, Jan; Gasche, Christoph
2014-01-01
Lynch syndrome (LS) accounts for 2 – 4 % of all colorectal cancers. Affected family members have a germline mutation in one of the DNA mismatch repair genes MLH1, PMS2, MSH2, or MSH6, and a lifetime risk for development of colorectal cancer of 25 – 75 %. Current guidelines recommend annual to biannual surveillance colonoscopy in mutation carriers. Several factors may predict failure to prevent interval cancer in LS: more lesions in the right colon; more flat (“non polypoid”) and lateral growing polyps; small adenomas may already harbor high grade dysplasia or a high percentage of villous component and become advanced adenomas; there is a short duration of the adenoma – carcinoma sequence; synchronous lesions have high prevalence; patients are younger and less tolerant to colonoscopy (need more sedation); and repeated colonoscopies are needed for lifelong surveillance (patient experience is important for compliance). In order to prevent cancer in LS patients, surveillance colonoscopy should be performed in an endoscopic unit experienced with LS, every 1 – 2 years, starting at age 20 – 25 years, or 10 years younger than the age of first diagnosis in the family (whichever is first), and yearly after the age of 40 years. Colonoscopy in LS patients should be a very meticulous and precise procedure (i. e. taking sufficient withdrawal time, documentation of such warranted), with removal of all of the polyps, special attention to the right colon and alertness to flat lesions. Following quality indicators such as successful cleansing of the colon and removal of every polyp will probably improve prevention of interval cancers. At this moment, none of the new endoscopic techniques have shown convincing superiority over conventional high resolution white light colonoscopy. PMID:26135102
Tensor hypercontraction. II. Least-squares renormalization
NASA Astrophysics Data System (ADS)
Parrish, Robert M.; Hohenstein, Edward G.; Martínez, Todd J.; Sherrill, C. David
2012-12-01
The least-squares tensor hypercontraction (LS-THC) representation for the electron repulsion integral (ERI) tensor is presented. Recently, we developed the generic tensor hypercontraction (THC) ansatz, which represents the fourth-order ERI tensor as a product of five second-order tensors [E. G. Hohenstein, R. M. Parrish, and T. J. Martínez, J. Chem. Phys. 137, 044103 (2012)], 10.1063/1.4732310. Our initial algorithm for the generation of the THC factors involved a two-sided invocation of overlap-metric density fitting, followed by a PARAFAC decomposition, and is denoted PARAFAC tensor hypercontraction (PF-THC). LS-THC supersedes PF-THC by producing the THC factors through a least-squares renormalization of a spatial quadrature over the otherwise singular 1/r12 operator. Remarkably, an analytical and simple formula for the LS-THC factors exists. Using this formula, the factors may be generated with O(N^5) effort if exact integrals are decomposed, or O(N^4) effort if the decomposition is applied to density-fitted integrals, using any choice of density fitting metric. The accuracy of LS-THC is explored for a range of systems using both conventional and density-fitted integrals in the context of MP2. The grid fitting error is found to be negligible even for extremely sparse spatial quadrature grids. For the case of density-fitted integrals, the additional error incurred by the grid fitting step is generally markedly smaller than the underlying Coulomb-metric density fitting error. The present results, coupled with our previously published factorizations of MP2 and MP3, provide an efficient, robust O(N^4) approach to both methods. Moreover, LS-THC is generally applicable to many other methods in quantum chemistry.
NASA Astrophysics Data System (ADS)
Chockanathan, Udaysankar; DSouza, Adora M.; Abidin, Anas Z.; Schifitto, Giovanni; Wismüller, Axel
2018-02-01
Resting-state functional MRI (rs-fMRI), coupled with advanced multivariate time-series analysis methods such as Granger causality, is a promising tool for the development of novel functional connectivity biomarkers of neurologic and psychiatric disease. Recently large-scale Granger causality (lsGC) has been proposed as an alternative to conventional Granger causality (cGC) that extends the scope of robust Granger causal analyses to high-dimensional systems such as the human brain. In this study, lsGC and cGC were comparatively evaluated on their ability to capture neurologic damage associated with HIV-associated neurocognitive disorders (HAND). Functional brain network models were constructed from rs-fMRI data collected from a cohort of HIV+ and HIV- subjects. Graph theoretic properties of the resulting networks were then used to train a support vector machine (SVM) model to predict clinically relevant parameters, such as HIV status and neuropsychometric (NP) scores. For the HIV+/- classification task, lsGC, which yielded a peak area under the receiver operating characteristic curve (AUC) of 0.83, significantly outperformed cGC, which yielded a peak AUC of 0.61, at all parameter settings tested. For the NP score regression task, lsGC, with a minimum mean squared error (MSE) of 0.75, significantly outperformed cGC, with a minimum MSE of 0.84 (p < 0.001, one-tailed paired t-test). These results show that, at optimal parameter settings, lsGC is better able to capture functional brain connectivity correlates of HAND than cGC. However, given the substantial variation in the performance of the two methods at different parameter settings, particularly for the regression task, improved parameter selection criteria are necessary and constitute an area for future research.
Tensor hypercontraction. II. Least-squares renormalization.
Parrish, Robert M; Hohenstein, Edward G; Martínez, Todd J; Sherrill, C David
2012-12-14
The least-squares tensor hypercontraction (LS-THC) representation for the electron repulsion integral (ERI) tensor is presented. Recently, we developed the generic tensor hypercontraction (THC) ansatz, which represents the fourth-order ERI tensor as a product of five second-order tensors [E. G. Hohenstein, R. M. Parrish, and T. J. Martínez, J. Chem. Phys. 137, 044103 (2012)]. Our initial algorithm for the generation of the THC factors involved a two-sided invocation of overlap-metric density fitting, followed by a PARAFAC decomposition, and is denoted PARAFAC tensor hypercontraction (PF-THC). LS-THC supersedes PF-THC by producing the THC factors through a least-squares renormalization of a spatial quadrature over the otherwise singular 1∕r(12) operator. Remarkably, an analytical and simple formula for the LS-THC factors exists. Using this formula, the factors may be generated with O(N(5)) effort if exact integrals are decomposed, or O(N(4)) effort if the decomposition is applied to density-fitted integrals, using any choice of density fitting metric. The accuracy of LS-THC is explored for a range of systems using both conventional and density-fitted integrals in the context of MP2. The grid fitting error is found to be negligible even for extremely sparse spatial quadrature grids. For the case of density-fitted integrals, the additional error incurred by the grid fitting step is generally markedly smaller than the underlying Coulomb-metric density fitting error. The present results, coupled with our previously published factorizations of MP2 and MP3, provide an efficient, robust O(N(4)) approach to both methods. Moreover, LS-THC is generally applicable to many other methods in quantum chemistry.
... DD. Hydrocarbons. In: Nelson LS, Lewin NA, Howland MA, Hoffman RS, Goldfrank LR, Flomenbaum NE, eds. Goldfrank's ... Dermatologic principles. In: Nelson LS, Lewin NA, Howland MA, Hoffman RS, Goldfrank LR, Flomenbaum NE, eds. Goldfrank's ...
How Bacterial Population Soliton Waves Can Defeat a Funnel Ring
NASA Astrophysics Data System (ADS)
Austin, Robert; Morris, Ryan; Phan, Average; Black, Matthew; Lin, Ke-Chih; Bos, Julia
We have constructed using microfabrication a circular corral for bacteria made of rings of concentric funnels which channel motile bacteria outwards via non-hydrodynamic interactions with the funnel walls. Although initially bacteria do move rapidly outwards with the funnels, they are able with increasing cell density on the perimeter to defeat the physical constraints of the funnel by launching collective, soliton like waves of bacteria inwards against the funnel ring. We present the basic data and some non-linear modeling which can explain the basic way that bacterial population solitons propagate across a funnel landscape. There are three surprising aspects to the experiments: (1) The bifurcation of the population into motile bacteria which are pumped by the funnels and bacteria which are non-motile (i.e., not pumped); (2) The launching of a collective wave which rapidly circles the device and radiates inwards against the pumping action of the funnel; (3) the subsequent loss of motility by all the bacteria after this burst of very high motility. Engineering and Physical Sciences Research Council [EP/J007404/1], National Cancer Institute (Grant No U54CA143803), and NSF PoLS program NSF PHY1521553.
An ultra-high gain and efficient amplifier based on Raman amplification in plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vieux, G.; Cipiccia, S.; Grant, D. W.
Raman amplification arising from the excitation of a density echelon in plasma could lead to amplifiers that significantly exceed current power limits of conventional laser media. Here we show that 1–100 J pump pulses can amplify picojoule seed pulses to nearly joule level. The extremely high gain also leads to significant amplification of backscattered radiation from “noise”, arising from stochastic plasma fluctuations that competes with externally injected seed pulses, which are amplified to similar levels at the highest pump energies. The pump energy is scattered into the seed at an oblique angle with 14 J sr -1, and net gainsmore » of more than eight orders of magnitude. The maximum gain coefficient, of 180 cm -1, exceeds high-power solid-state amplifying media by orders of magnitude. The observation of a minimum of 640 J sr -1 directly backscattered from noise, corresponding to ≈10% of the pump energy in the observation solid angle, implies potential overall efficiencies greater than 10%.« less
An ultra-high gain and efficient amplifier based on Raman amplification in plasma
Vieux, G.; Cipiccia, S.; Grant, D. W.; ...
2017-05-25
Raman amplification arising from the excitation of a density echelon in plasma could lead to amplifiers that significantly exceed current power limits of conventional laser media. Here we show that 1–100 J pump pulses can amplify picojoule seed pulses to nearly joule level. The extremely high gain also leads to significant amplification of backscattered radiation from “noise”, arising from stochastic plasma fluctuations that competes with externally injected seed pulses, which are amplified to similar levels at the highest pump energies. The pump energy is scattered into the seed at an oblique angle with 14 J sr -1, and net gainsmore » of more than eight orders of magnitude. The maximum gain coefficient, of 180 cm -1, exceeds high-power solid-state amplifying media by orders of magnitude. The observation of a minimum of 640 J sr -1 directly backscattered from noise, corresponding to ≈10% of the pump energy in the observation solid angle, implies potential overall efficiencies greater than 10%.« less
Stecher, David; Bronkers, Glenn; Noest, Jappe O.T.; Tulleken, Cornelis A.F.; Hoefer, Imo E.; van Herwerden, Lex A.; Pasterkamp, Gerard; Buijsrogge, Marc P.
2014-01-01
To simplify and facilitate beating heart (i.e., off-pump), minimally invasive coronary artery bypass surgery, a new coronary anastomotic connector, the Trinity Clip, is developed based on the excimer laser-assisted nonocclusive anastomosis technique. The Trinity Clip connector enables simplified, sutureless, and nonocclusive connection of the graft to the coronary artery, and an excimer laser catheter laser-punches the opening of the anastomosis. Consequently, owing to the complete nonocclusive anastomosis construction, coronary conditioning (i.e., occluding or shunting) is not necessary, in contrast to the conventional anastomotic technique, hence simplifying the off-pump bypass procedure. Prior to clinical application in coronary artery bypass grafting, the safety and quality of this novel connector will be evaluated in a long-term experimental porcine off-pump coronary artery bypass (OPCAB) study. In this paper, we describe how to evaluate the coronary anastomosis in the porcine OPCAB model using various techniques to assess its quality. Representative results are summarized and visually demonstrated. PMID:25490000
Preparation of Gd Loaded Liquid Scintillator for Daya Bay Neutrino Experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding Yayun; Zhang Zhiyong
2010-05-12
Gadolinium loaded liquid scintillator (Gd-LS) is an excellent target material for reactor antineutrino experiments. Ideal Gd-LS should have long attenuation length, high light yield, long term stability, low toxicity, and should be compatible with the material used to build the detector. We have developed a new Gd-LS recipe in which carboxylic acid 3,5,5-trimethylhexanoic acid is used as the complexing ligand to gadolinium, 2,5-diphenyloxazole (PPO) and 1,4-bis[2-methylstyryl]benzene (bis-MSB) are used as primary fluor and wavelength shifter, respectively. The scintillator base is linear alkyl benzene (LAB). Eight hundred liters of Gd-LS has been synthesized and tested in a prototype detector. Results showmore » that the Gd-LS has high quality and is suitable for underground experiments in large quantity. Large scale production facility has been built. A full batch production of 4 t Gd-LS has been produced and monitored for several months. The production of 180 t Gd-LS will be carried out in the near future.« less
Elemental Water Impact Test: Phase 3 Plunge Depth of a 36-Inch Aluminum Tank Head
NASA Technical Reports Server (NTRS)
Vassilakos, Gregory J.
2014-01-01
Spacecraft are being designed based on LS-DYNA water landing simulations. The Elemental Water Impact Test (EWIT) series was undertaken to assess the accuracy of LS-DYNA water impact simulations. Phase 3 featured a composite tank head that was tested at a range of heights to verify the ability to predict structural failure of composites. To support planning for Phase 3, a test series was conducted with an aluminum tank head dropped from heights of 2, 6, 10, and 12 feet to verify that the test article would not impact the bottom of the test pool. This report focuses on the comparisons of the measured plunge depths to LS-DYNA predictions. The results for the tank head model demonstrated the following. 1. LS-DYNA provides accurate predictions for peak accelerations. 2. LS-DYNA consistently under-predicts plunge depth. An allowance of at least 20% should be added to the LS-DYNA predictions. 3. The LS-DYNA predictions for plunge depth are relatively insensitive to the fluid-structure coupling stiffness.
Chen, Xi; Shi, Yuechun; Lou, Fei; Chen, Yiting; Yan, Min; Wosinski, Lech; Qiu, Min
2014-10-20
An optically pumped thermo-optic (TO) silicon ring add-drop filter with fast thermal response is experimentally demonstrated. We propose that metal-insulator-metal (MIM) light absorber can be integrated into silicon TO devices, acting as a localized heat source which can be activated remotely by a pump beam. The MIM absorber design introduces less thermal capacity to the device, compared to conventional electrically-driven approaches. Experimentally, the absorber-integrated add-drop filter shows an optical response time of 13.7 μs following the 10%-90% rule (equivalent to a exponential time constant of 5 μs) and a wavelength shift over pump power of 60 pm/mW. The photothermally tunable add-drop filter may provide new perspectives for all-optical routing and switching in integrated Si photonic circuits.
Comfortable, high-efficiency heat pump with desiccant-coated, water-sorbing heat exchangers.
Tu, Y D; Wang, R Z; Ge, T S; Zheng, X
2017-01-12
Comfortable, efficient, and affordable heating, ventilation, and air conditioning systems in buildings are highly desirable due to the demands of energy efficiency and environmental friendliness. Traditional vapor-compression air conditioners exhibit a lower coefficient of performance (COP) (typically 2.8-3.8) owing to the cooling-based dehumidification methods that handle both sensible and latent loads together. Temperature- and humidity-independent control or desiccant systems have been proposed to overcome these challenges; however, the COP of current desiccant systems is quite small and additional heat sources are usually needed. Here, we report on a desiccant-enhanced, direct expansion heat pump based on a water-sorbing heat exchanger with a desiccant coating that exhibits an ultrahigh COP value of more than 7 without sacrificing any comfort or compactness. The pump's efficiency is doubled compared to that of pumps currently used in conventional room air conditioners, which is a revolutionary HVAC breakthrough. Our proposed water-sorbing heat exchanger can independently handle sensible and latent loads at the same time. The desiccants adsorb moisture almost isothermally and can be regenerated by condensation heat. This new approach opens up the possibility of achieving ultrahigh efficiency for a broad range of temperature- and humidity-control applications.
Ackerman, Stacey J; Daniel, Shoshana; Baik, Rebecca; Liu, Emelline; Mehendale, Shilpa; Tackett, Scott; Hellan, Minia
2018-03-01
To compare (1) complication and (2) conversion rates to open surgery (OS) from laparoscopic surgery (LS) and robotic-assisted surgery (RA) for rectal cancer patients who underwent rectal resection. (3) To identify patient, physician, and hospital predictors of conversion. A US-based database study was conducted utilizing the 2012-2014 Premier Healthcare Data, including rectal cancer patients ≥18 with rectal resection. ICD-9-CM diagnosis and procedural codes were utilized to identify surgical approaches, conversions to OS, and surgical complications. Propensity score matching on patient, surgeon, and hospital level characteristics was used to create comparable groups of RA\\LS patients (n = 533 per group). Predictors of conversion from LS and RA to OS were identified with stepwise logistic regression in the unmatched sample. Post-match results suggested comparable perioperative complication rates (RA 29% vs LS 29%; p = .7784); whereas conversion rates to OS were 12% for RA vs 29% for LS (p < .0001). Colorectal surgeons (RA 9% vs LS 23%), general surgeons (RA 13% vs LS 35%), and smaller bed-size hospitals (RA 14% vs LS 33%) have reduced conversion rates for RA vs LS (p < .0001). Statistically significant predictors of conversion included LS, non-colorectal surgeon, and smaller bed-size hospitals. Retrospective observational study limitations apply. Analysis of the hospital administrative database was subject to the data captured in the database and the accuracy of coding. Propensity score matching limitations apply. RA and LS groups were balanced with respect to measured patient, surgeon, and hospital characteristics. Compared to LS, RA offers a higher probability of completing a successful minimally invasive surgery for rectal cancer patients undergoing rectal resection without exacerbating complications. Male, obese, or moderately-to-severely ill patients had higher conversion rates. While colorectal surgeons had lower conversion rates from RA than LS, the reduction was magnified for general surgeons and smaller bed-size hospitals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Xiaobing; Malhotra, Mini; Xiong, Zeyu
High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects, a distributed GSHP system for providing all the space conditioning, outdoor air ventilation, and 100% domestic hot water tomore » the Wilders Grove Solid Waste Service Center of City of Raleigh, North Carolina. This case study is based on the analysis of measured performance data, construction costs, and simulations of the energy consumption of conventional central heating, ventilation, and air-conditioning (HVAC) systems providing the same level of space conditioning and outdoor air ventilation as the demonstrated GSHP system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GSHP system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the GSHP system compared with conventional HVAC systems. This case study also identified opportunities for reducing uncertainties in the performance evaluation and improving the operational efficiency of the demonstrated GSHP system.« less
Thermodynamic and economic analysis of heat pumps for energy recovery in industrial processes
NASA Astrophysics Data System (ADS)
Urdaneta-B, A. H.; Schmidt, P. S.
1980-09-01
A computer code has been developed for analyzing the thermodynamic performance, cost and economic return for heat pump applications in industrial heat recovery. Starting with basic defining characteristics of the waste heat stream and the desired heat sink, the algorithm first evaluates the potential for conventional heat recovery with heat exchangers, and if applicable, sizes the exchanger. A heat pump system is then designed to process the residual heating and cooling requirements of the streams. In configuring the heat pump, the program searches a number of parameters, including condenser temperature, evaporator temperature, and condenser and evaporator approaches. All system components are sized for each set of parameters, and economic return is estimated and compared with system economics for conventional processing of the heated and cooled streams (i.e., with process heaters and coolers). Two case studies are evaluated, one in a food processing application and the other in an oil refinery unit.
Interfacial Tension in the CaO-Al2O3-SiO2-(MgO) Liquid Slag-Solid Oxide Systems
NASA Astrophysics Data System (ADS)
Abdeyazdan, Hamed; Monaghan, Brian J.; Longbottom, Raymond J.; Rhamdhani, M. Akbar; Dogan, Neslihan; Chapman, Michael W.
2017-08-01
Interfacial phenomenon is critical in metal processing and refining. While it is known to be important, there are little data available for key oxide systems in the literature. In this study, the interfacial tension ( σ LS) of liquid slag on solid oxides (alumina, spinel, and calcium aluminate), for a range of slags in the CaO-Al2O3-SiO2-(MgO) system at 1773 K (1500 °C), has been evaluated. The results show that basic ladle-type slags exhibit lower σ LS with oxide phases examined compared to that of acid tundish-type slags. Also, within the slag types (acid and base), σ LS was observed to decrease with increasing slag basicity. A correlation between σ LS and slag structure was observed, i.e., σ LS was found to decrease linearly with increasing of slag optical basicity (Λ) and decrease logarithmically with decreasing of slag viscosity from acid to base slags. This indicated a higher σ LS as the ions in the slag become larger and more complex. Through a work of adhesion ( W) analysis, it was shown that basic ladle slags with lower σ LS result in a greater W, i.e., form a stronger bond with the solid oxide phases examined. This indicates that all other factors being equal, the efficiency of inclusion removal from steel of inclusions of similar phase to these solid oxides would be greater.
Botelho, M A; Rao, V S; Carvalho, C B M; Bezerra-Filho, J G; Fonseca, S G C; Vale, M L; Montenegro, D; Cunha, F; Ribeiro, R A; Brito, G A
2007-09-25
In Brazilian folk medicine, Lippia sidoides (Ls) and Myracrodruon urundeuva (Mu) have gained popularity and reputation as effective antimicrobial and anti-inflammatory agents. This work aimed to evaluate the effect of topical herbal gel from Ls 0.5% (v/w) and Mu 5% (w/w) in experimental periodontal disease (EPD) in rats. Wistar rats were subjected to ligature placement around the second upper left molars. Animals were treated topically with Ls and/or Mu-based gel, immediately after EPD induction and three times/day for 11 days until the rats were sacrificed (11th day). Saline-based gel was utilized as control for all experiments and doxycycline based gel 10% (w/w) was utilized as reference substance. Animals were weighed daily. Alveolar bone loss was measured as the difference (in millimeters) between the cusp tip and the alveolar bone. The periodontum and the surrounding gingivae were examined at histopathology, as well as the neutrophil influx into the gingivae was assayed using myeloperoxidase activity and cytokine production mainly tumor necrosis factor-alpha (TNF-alpha) and interleukin-1beta (IL-1beta) levels by ELISA method. The local bacterial flora was assessed through culture of the gingival tissue in standard aerobic and anaerobic media. Alveolar bone loss was significantly inhibited by Ls and Mu combined treatment compared to the saline control group. Ls and Mu combined treatment reduced tissue lesion at histopathology, with partial preservation of the periodontum, coupled to decreased myeloperoxidase activity as well as significantly inhibited TNF-alpha and IL-1beta production in gingival tissue compared to the saline control group. Ls and Mu combined treatment also prevented the growth of oral microorganisms and the weight loss. Ls and Mu combined based gel treatment preserved alveolar bone resorption and demonstrated anti-inflammatory and antibacterial activities in experimental periodontitis.
Cost-Effectiveness Analysis of Different Genetic Testing Strategies for Lynch Syndrome in Taiwan.
Chen, Ying-Erh; Kao, Sung-Shuo; Chung, Ren-Hua
2016-01-01
Patients with Lynch syndrome (LS) have a significantly increased risk of developing colorectal cancer (CRC) and other cancers. Genetic screening for LS among patients with newly diagnosed CRC aims to identify mutations in the disease-causing genes (i.e., the DNA mismatch repair genes) in the patients, to offer genetic testing for relatives of the patients with the mutations, and then to provide early prevention for the relatives with the mutations. Several genetic tests are available for LS, such as DNA sequencing for MMR genes and tumor testing using microsatellite instability and immunohistochemical analyses. Cost-effectiveness analyses of different genetic testing strategies for LS have been performed in several studies from different countries such as the US and Germany. However, a cost-effectiveness analysis for the testing has not yet been performed in Taiwan. In this study, we evaluated the cost-effectiveness of four genetic testing strategies for LS described in previous studies, while population-specific parameters, such as the mutation rates of the DNA mismatch repair genes and treatment costs for CRC in Taiwan, were used. The incremental cost-effectiveness ratios based on discounted life years gained due to genetic screening were calculated for the strategies relative to no screening and to the previous strategy. Using the World Health Organization standard, which was defined based on Taiwan's Gross Domestic Product per capita, the strategy based on immunohistochemistry as a genetic test followed by BRAF mutation testing was considered to be highly cost-effective relative to no screening. Our probabilistic sensitivity analysis results also suggest that the strategy has a probability of 0.939 of being cost-effective relative to no screening based on the commonly used threshold of $50,000 to determine cost-effectiveness. To the best of our knowledge, this is the first cost-effectiveness analysis for evaluating different genetic testing strategies for LS in Taiwan. The results will be informative for the government when considering offering screening for LS in patients newly diagnosed with CRC.
Shahlaei, M.; Saghaie, L.
2014-01-01
A quantitative structure–activity relationship (QSAR) study is suggested for the prediction of biological activity (pIC50) of 3, 4-dihydropyrido [3,2-d] pyrimidone derivatives as p38 inhibitors. Modeling of the biological activities of compounds of interest as a function of molecular structures was established by means of principal component analysis (PCA) and least square support vector machine (LS-SVM) methods. The results showed that the pIC50 values calculated by LS-SVM are in good agreement with the experimental data, and the performance of the LS-SVM regression model is superior to the PCA-based model. The developed LS-SVM model was applied for the prediction of the biological activities of pyrimidone derivatives, which were not in the modeling procedure. The resulted model showed high prediction ability with root mean square error of prediction of 0.460 for LS-SVM. The study provided a novel and effective approach for predicting biological activities of 3, 4-dihydropyrido [3,2-d] pyrimidone derivatives as p38 inhibitors and disclosed that LS-SVM can be used as a powerful chemometrics tool for QSAR studies. PMID:26339262
Hudson, Jessica L; Bell, Jennifer M; Crabtree, Traves D; Kreisel, Daniel; Patterson, G Alexander; Meyers, Bryan F; Puri, Varun
2018-01-01
Formal pulmonary function testing with laboratory spirometry (LS) is the standard of care for risk stratification before lung resection. LS and handheld office spirometry (OS) are clinically comparable for forced expiratory volume in 1 second and forced vital capacity. We investigated the safety of preoperative risk stratification based solely on OS. Patients at low-risk for cardiopulmonary complications were enrolled in a single-center prospective study and underwent preoperative OS. Formal LS was not performed when forced expiratory volume in 1 second was more than 60% by OS. Propensity score matching was used to compare patients in the OS group to low-risk institutional database patients (2008 to 2015) who underwent LS and lung resection. Standardized mean differences determined model covariate balance. The McNemar test and log-rank test were performed, respectively, for categorical and continuous paired outcome data. There were 66 prospectively enrolled patients who received OS and underwent pulmonary resection, and 1,290 patients received preoperative LS, resulting in 52 propensity score-matched pairs (83%). There were no deaths and two 30-day readmissions per group. The major morbidity risk was similar in each group (7.7%). All analyses of discordant pair morbidity had p exceeding 0.56. There was no association between length of stay and exposure to OS vs LS (p = 0.31). The estimated annual institutional cost savings from performing OS only and avoiding LS was $38,000. Low-risk patients undergoing lung resection can be adequately and safely assessed using OS without formal LS, with significant cost savings. With upcoming bundled care reimbursement paradigms, such safe and effective strategies are likely to be more widely used. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Kulshreshtha, Ambar; Vaccarino, Viola; Judd, Suzanne; Howard, Virginia J.; McClellan, William; Muntner, Paul; Hong, Yuling; Safford, Monika; Goyal, Abhinav; Cushman, Mary
2013-01-01
Background and Purpose The American Heart Association developed Life’s Simple 7 (LS7) as a metric defining cardiovascular health. We investigated the association between LS7 and incident stroke in black and white Americans. Methods REGARDS is a national population-based cohort of 30,239 blacks and whites, aged ≥45 years, sampled from the US population in 2003 – 2007. Data were collected by telephone, self-administered questionnaires and an in-home exam. Incident strokes were identified through bi-annual participant contact followed by adjudication of medical records. Levels of the LS7 components (blood pressure, cholesterol, glucose, body mass index, smoking, physical activity, and diet) were each coded as poor (0 point), intermediate (1 point) or ideal (2 points) health. An overall LS7 score was categorized as inadequate (0–4), average (5–9) or optimum (10–14) cardiovascular health. Results Among 22,914 subjects with LS7 data and no previous cardiovascular disease, there were 432 incident strokes over 4.9 years of follow-up. After adjusting for demographics, socioeconomic status, and region of residence, each better health category of the LS7 score was associated with a 25% lower risk of stroke (HR=0.75, 95% CI = 0.63, 0.90). The association was similar for blacks and whites (interaction p-value = 0.55). A one point higher LS7 score was associated with an 8% lower risk of stroke (HR=0.92, 95% CI=0.88, 0.95). Conclusion In both blacks and whites better cardiovascular health, based on the LS7 score, is associated with lower risk of stroke, and a small difference in scores was an important stroke determinant. PMID:23743971
NASA Technical Reports Server (NTRS)
Hoang, Triem T.; OConnell, Tamara; Ku, Jentung
2004-01-01
Loop Heat Pipes (LHPs) have proven themselves as reliable and robust heat transport devices for spacecraft thermal control systems. So far, the LHPs in earth-orbit satellites perform very well as expected. Conventional LHPs usually consist of a single capillary pump for heat acquisition and a single condenser for heat rejection. Multiple pump/multiple condenser LHPs have shown to function very well in ground testing. Nevertheless, the test results of a dual pump/condenser LHP also revealed that the dual LHP behaved in a complicated manner due to the interaction between the pumps and condensers. Thus it is redundant to say that more research is needed before they are ready for 0-g deployment. One research area that perhaps compels immediate attention is the analytical modeling of LHPs, particularly the transient phenomena. Modeling a single pump/single condenser LHP is difficult enough. Only a handful of computer codes are available for both steady state and transient simulations of conventional LHPs. No previous effort was made to develop an analytical model (or even a complete theory) to predict the operational behavior of the multiple pump/multiple condenser LHP systems. The current research project offered a basic theory of the multiple pump/multiple condenser LHP operation. From it, a computer code was developed to predict the LHP saturation temperature in accordance with the system operating and environmental conditions.
ARPA solid state laser and nonlinear materials program
NASA Astrophysics Data System (ADS)
Moulton, Peter F.
1994-06-01
The Research Division of Schwartz Electro-Optics, as part of the ARPA Solid State Laser and Nonlinear Materials Program, conducted a three-year study 'Erbium-Laser-Based Infrared Sources.' The aim of the study was to improve the understanding of semiconductor-laser-pumped, infrared (IR) solid state lasers based on the trivalent rare-earth ion erbium (Er) doped into a variety of host crystals. The initial program plan emphasized operation of erbium-doped materials on the 2.8-3.0 micrometers laser transition. Pulsed, Q-switched sources using that transition, when employed as a pump source for parametric oscillators, can provide tunable mid-IR energy. The dynamics of erbium lasers are more complex than conventional neodymium (Nd)-doped lasers and we intended to use pump-probe techniques to measure the level and temporal behavior of gain in various materials. To do so we constructed a number of different cw Er-doped lasers as probe sources and employed the Cr:LiSAF(LiSrAlF6) laser as a pulsed pump source that would simulate pulsed diode arrays. We identified the 970-nm wavelength pump band of Er as the most efficient and were able to make use of recently developed cw and pulsed InGaAs strained-quantum-well diode lasers in the effort. At the conclusion of the program we demonstrated the first pulsed diode bar pumping of the most promising materials for pulsed operation, the oxide garnets YSGG and GGG and the fluoride BaY2F8.
NASA Astrophysics Data System (ADS)
Sant, T.; Buhagiar, D.; Farrugia, R. N.
2014-06-01
A new concept utilising floating wind turbines to exploit the low temperatures of deep sea water for space cooling in buildings is presented. The approach is based on offshore hydraulic wind turbines pumping pressurised deep sea water to a centralised plant consisting of a hydro-electric power system coupled to a large-scale sea water-cooled air conditioning (AC) unit of an urban district cooling network. In order to investigate the potential advantages of this new concept over conventional technologies, a simplified model for performance simulation of a vapour compression AC unit was applied independently to three different systems, with the AC unit operating with (1) a constant flow of sea surface water, (2) a constant flow of sea water consisting of a mixture of surface sea water and deep sea water delivered by a single offshore hydraulic wind turbine and (3) an intermittent flow of deep sea water pumped by a single offshore hydraulic wind turbine. The analysis was based on one year of wind and ambient temperature data for the Central Mediterranean that is known for its deep waters, warm climate and relatively low wind speeds. The study confirmed that while the present concept is less efficient than conventional turbines utilising grid-connected electrical generators, a significant portion of the losses associated with the hydraulic transmission through the pipeline are offset by the extraction of cool deep sea water which reduces the electricity consumption of urban air-conditioning units.
Zonato, Valeria; Vanin, Stefano; Costa, Rodolfo; Tauber, Eran; Kyriacou, Charalambos P
2018-02-01
The spread of adaptive genetic variants in populations is a cornerstone of evolutionary theory but with relatively few biologically well-understood examples. Previous work on the ls-tim variant of timeless, which encodes the light-sensitive circadian regulator in Drosophila melanogaster, suggests that it may have originated in southeastern Italy. Flies characterized by the new allele show photoperiod-related phenotypes likely to be adaptive in seasonal environments. ls-tim may be spreading from its point of origin in Italy by directional selection, but there are alternative explanations for its observed clinal geographical distribution, including balancing selection and demography. From population analyses of ls-tim frequencies collected on the eastern side of the Iberian Peninsula, we show that ls-tim frequencies are inverted compared with those in Italy. This pattern is consistent with a scenario of directional selection rather than latitude-associated balancing selection. Neutrality tests further reveal the signature of directional selection at the ls-tim site, which is reduced a few kb pairs either side of ls-tim. A reanalysis of allele frequencies from a large number of microsatellite loci do not demonstrate any frequent ls-tim-like spatial patterns, so a general demographic effect or population expansion from southeastern Italy cannot readily explain current ls-tim frequencies. Finally, a revised estimate of the age of ls-tim allele using linkage disequilibrium and coalescent-based approaches reveals that it may be only 300 to 3000 years old, perhaps explaining why it has not yet gone to fixation. ls-tim thus provides a rare temporal snapshot of a new allele that has come under selection before it reaches equilibrium.
Biodegradation test of SPS-LS blends as polymer electrolyte membrane fuel cells
NASA Astrophysics Data System (ADS)
Putri, Zufira; Arcana, I. Made
2014-03-01
Sulfonated polystyrene (SPS) can be applied as a proton exchange membrane fuel cell due to its fairly good chemical stability. In order to be applied as polymer electrolyte membrane fuel cells (PEMFCs), membrane polymer should have a good ionic conductivity, high proton conductivity, and high mechanical strength. Lignosulfonate (LS) is a complex biopolymer which has crosslinks and sulfonate groups. SPS-LS blends with addition of SiO2 are used to increase the proton conductivity and to improve the mechanical properties and thermal stability. However, the biodegradation test of SPS-LS blends is required to determine whether the application of these membranes to be applied as an environmentally friendly membrane. In this study, had been done the synthesis of SPS, biodegradability test of SPS-LS blends with variations of LS and SiO2 compositions. The biodegradation test was carried out in solid medium of Luria Bertani (LB) with an activated sludge used as a source of microorganism at incubation temperature of 37°C. Based on the results obtained indicated that SPS-LS-SiO2 blends are more decomposed by microorganism than SPS-LS blends. This result is supported by analysis of weight reduction percentage, functional groups with Fourier Transform Infrared (FTIR) Spectroscopy, and morphological surface with Scanning Electron Microscopy (SEM).
Compact and highly efficient laser pump cavity
Chang, Jim J.; Bass, Isaac L.; Zapata, Luis E.
1999-01-01
A new, compact, side-pumped laser pump cavity design which uses non-conventional optics for injection of laser-diode light into a laser pump chamber includes a plurality of elongated light concentration channels. In one embodiment, the light concentration channels are compound parabolic concentrators (CPC) which have very small exit apertures so that light will not escape from the pumping chamber and will be multiply reflected through the laser rod. This new design effectively traps the pump radiation inside the pump chamber that encloses the laser rod. It enables more uniform laser pumping and highly effective recycle of pump radiation, leading to significantly improved laser performance. This new design also effectively widens the acceptable radiation wavelength of the diodes, resulting in a more reliable laser performance with lower cost.
Near-Infrared Laser Pumped Intersubband THz Laser Gain in InGaAs-AlAsSb-InP Quantum Wells
NASA Technical Reports Server (NTRS)
Liu, An-Sheng; Ning, Cun-Zheng
1999-01-01
We investigate the possibility of using InGaAs-AlAsSb-InP coupled quantum wells to generate THz radiation by means of intersubband optical pumping. We show that large conduction band offsets of these quantum wells make it possible to use conventional near-infrared diode lasers around 1.55 micron as pump sources. Taking into account the pump-probe coherent interaction and the optical nonlinearity for the pump field, we calculate the THz gain of the quantum well structure. We show that resonant Raman scattering enhances the THz gain at low and moderate optical pumping levels. When the pump intensity is strong, the THz gain is reduced by pump-induced population redistribution and pump-probe coherent interactions.
Borot, Sophie; Franc, Sylvia; Cristante, Justine; Penfornis, Alfred; Benhamou, Pierre-Yves; Guerci, Bruno; Hanaire, Hélène; Renard, Eric; Reznik, Yves; Simon, Chantal
2014-01-01
The JewelPUMP™ (JP) is a new patch pump based on a microelectromechanical system that operates without any plunger. The study aimed to evaluate the infusion accuracy of the JP in vitro and in vivo. For the in vitro studies, commercially available pumps meeting the ISO standard were compared to the JP: the MiniMed® Paradigm® 712 (MP), Accu-Chek® Combo (AC), OmniPod® (OP), Animas® Vibe™ (AN). Pump accuracy was measured over 24 hours using a continuous microweighing method, at 0.1 and 1 IU/h basal rates. The occlusion alarm threshold was measured after a catheter occlusion. The JP, filled with physiological serum, was then tested in 13 patients with type 1 diabetes simultaneously with their own pump for 2 days. The weight difference was used to calculate the infused insulin volume. The JP showed reduced absolute median error rate in vitro over a 15-minute observation window compared to other pumps (1 IU/h): ±1.02% (JP) vs ±1.60% (AN), ±1.66% (AC), ±2.22% (MP), and ±4.63% (OP), P < .0001. But there was no difference over 24 hours. At 0.5 IU/h, the JP was able to detect an occlusion earlier than other pumps: 21 (19; 25) minutes vs 90 (85; 95), 58 (42; 74), and 143 (132; 218) minutes (AN, AC, MP), P < .05 vs AN and MP. In patients, the 24-hour flow error was not significantly different between the JP and usual pumps (–2.2 ± 5.6% vs –0.37 ± 4.0%, P = .25). The JP was found to be easier to wear than conventional pumps. The JP is more precise over a short time period, more sensitive to catheter occlusion, well accepted by patients, and consequently, of potential interest for a closed-loop insulin delivery system. PMID:25079676
Eddy current characterization of small cracks using least square support vector machine
NASA Astrophysics Data System (ADS)
Chelabi, M.; Hacib, T.; Le Bihan, Y.; Ikhlef, N.; Boughedda, H.; Mekideche, M. R.
2016-04-01
Eddy current (EC) sensors are used for non-destructive testing since they are able to probe conductive materials. Despite being a conventional technique for defect detection and localization, the main weakness of this technique is that defect characterization, of the exact determination of the shape and dimension, is still a question to be answered. In this work, we demonstrate the capability of small crack sizing using signals acquired from an EC sensor. We report our effort to develop a systematic approach to estimate the size of rectangular and thin defects (length and depth) in a conductive plate. The achieved approach by the novel combination of a finite element method (FEM) with a statistical learning method is called least square support vector machines (LS-SVM). First, we use the FEM to design the forward problem. Next, an algorithm is used to find an adaptive database. Finally, the LS-SVM is used to solve the inverse problems, creating polynomial functions able to approximate the correlation between the crack dimension and the signal picked up from the EC sensor. Several methods are used to find the parameters of the LS-SVM. In this study, the particle swarm optimization (PSO) and genetic algorithm (GA) are proposed for tuning the LS-SVM. The results of the design and the inversions were compared to both simulated and experimental data, with accuracy experimentally verified. These suggested results prove the applicability of the presented approach.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Im, Piljae; Liu, Xiaobing
High initial costs and lack of public awareness of ground-source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy-saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights the findings of a case study of one of the ARRA-funded GSHP demonstration projects, a ground-source variable refrigerant flow (GS-VRF) system installed at the Human Health Building at Oakland University in Rochester, Michigan.more » This case study is based on the analysis of measured performance data, maintenance records, construction costs, and simulations of the energy consumption of conventional central heating, ventilation, and air-conditioning (HVAC) systems providing the same level of space conditioning as the demonstrated GS-VRF system. The evaluated performance metrics include the energy efficiency of the heat pump equipment and the overall GS-VRF system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of the GS-VRF system compared with conventional HVAC systems. This case study also identified opportunities for reducing uncertainties in the performance evaluation, improving the operational efficiency, and reducing the installed cost of similar GSHP systems in the future.« less
Ultra high vacuum pumping system and high sensitivity helium leak detector
Myneni, Ganapati Rao
1997-01-01
An improved helium leak detection method and apparatus are disclosed which increase the leak detection sensitivity to 10.sup.-13 atm cc s.sup.-1. The leak detection sensitivity is improved over conventional leak detectors by completely eliminating the use of o-rings, equipping the system with oil-free pumping systems, and by introducing measured flows of nitrogen at the entrances of both the turbo pump and backing pump to keep the system free of helium background. The addition of dry nitrogen flows to the system reduces backstreaming of atmospheric helium through the pumping system as a result of the limited compression ratios of the pumps for helium.
GaAs laser diode pumped Nd:YAG laser
NASA Technical Reports Server (NTRS)
Conant, L. C.; Reno, C. W.
1974-01-01
A 1.5-mm by 3-cm neodymium-ion doped YAG laser rod has been side pumped using a GaAs laser diode array tuned to the 8680-A absorption line, achieving a multimode average output power of 120 mW for a total input power of 20 W to the final-stage laser diode drivers. The pumped arrangement was designed to take advantage of the high brightness of a conventional GaAs array as a linear source by introducing the pump light through a slit into a close-wrapped gold coated pump cavity. This cavity forms an integrating chamber for the pump light.
Vapor deposition on doublet airfoil substrates: Control of coating thickness and microstructure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rodgers, Theron M.; Zhao, Hengbei; Wadley, Haydn N. G., E-mail: haydn@virginia.edu
Gas jet assisted vapor deposition processes for depositing coatings are conducted at higher pressures than conventional physical vapor deposition methods, and have shown promise for coating complex shaped substrates including those with non-line-of-sight (NLS) regions on their surface. These regions typically receive vapor atoms at a lower rate and with a wider incident angular distribution than substrate regions in line-of-sight (LS) of the vapor source. To investigate the coating of such substrates, the thickness and microstructure variation along the inner (curved) surfaces of a model doublet airfoil containing both LS and NLS regions has been investigated. Results from atomistic simulationsmore » and experiments confirm that the coating's thickness is thinner in flux-shadowed regions than in other regions for all the coating processes investigated. They also indicated that the coatings columnar microstructure and pore volume fraction vary with surface location through the LS to NLS transition zone. A substrate rotation strategy for optimizing the thickness over the entire doublet airfoil surface was investigated, and led to the identification of a process that resulted in only small variation of coating thickness, columnar growth angle, and pore volume fraction on all doublet airfoil surfaces.« less
Piñero, David P.; Camps, Vicente J.; Ramón, María L.; Mateo, Verónica; Pérez-Cambrodí, Rafael J.
2015-01-01
AIM To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). RESULTS PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors. PMID:26085998
Piñero, David P; Camps, Vicente J; Ramón, María L; Mateo, Verónica; Pérez-Cambrodí, Rafael J
2015-01-01
To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.
Neukam, K; Morano-Amado, L E; Rivero-Juárez, A; Macías, J; Granados, R; Romero-Palacios, A; Márquez, M; Merino, D; Ortega, E; Alados-Arboledas, J C; Cucurull, J; Omar, M; Ryan-Murua, P; Pineda, J A
2017-05-01
The purpose of this investigation was to evaluate the impact of liver stiffness (LS) on the response to direct-acting antiviral (DAA)-based therapy against hepatitis C virus (HCV) infection in cirrhotic patients. Those patients included in two Spanish prospective cohorts of patients receiving therapy based on at least one DAA, who showed a baseline LS ≥ 12.5 kPa and who had reached the scheduled time point for sustained virological response evaluation 12 weeks after completing therapy (SVR12) were analysed. Pegylated interferon/ribavirin-based therapy plus an HCV NS3/4A protease inhibitor (PR-PI group) was administered to 198 subjects, while 146 received interferon-free regimens (IFN-free group). The numbers of patients with SVR12 according to an LS < 21 kPa versus ≥21 kPa were 59/99 (59.6%) versus 46/99 (46.5%) in the PR-PI group (p = 0.064) and 41/43 (95.3%) versus 90/103 (87.4%) in the IFN-free group (p = 0.232). Corresponding figures for the relapse rates in those who presented end-of-treatment response (ETR) were 3/62 (4.8%) versus 10/56 (17.9%, p = 0.024) and 1/42 (2.4%) versus 8/98 (8.2%, p = 0.278), respectively. In a multivariate analysis adjusted for age, sex and use of interferon, a baseline LS ≥ 21 kPa was identified as an independent predictor of relapse [adjusted odds ratio, AOR (95% confidence interval, CI): 4.228 (1.344-13.306); p = 0.014] in those patients with ETR. LS above 21 kPa is associated with higher rates of relapse to DAA-based therapy in HCV-infected patients with cirrhosis in clinical practice. LS could help us to tailor the duration and composition of DAA-based combinations in cirrhotic subjects, in order to minimise the likelihood of relapse.
Hartman, Douglas J; Brand, Randall E; Hu, Huankai; Bahary, Nathan; Dudley, Beth; Chiosea, Simon I; Nikiforova, Marina N; Pai, Reetesh K
2013-11-01
The optimal strategy for screening patients with colorectal carcinoma for Lynch syndrome (LS) is a subject of continued debate in the literature with some advocating universal screening while others arguing for selective screening. We evaluated 1292 colorectal carcinomas for DNA mismatch repair protein abnormalities and identified 150 (11.6%) tumors demonstrating high-levels of microsatellite instability (MSI-H). MSI-H colorectal carcinomas were divided into sporadic (112/1292, 8.7%) and LS/probable LS-associated (38/1292, 2.9%) groups based on BRAF V600E mutation, MLH1 promoter hypermethylation, cancer history, and germline mismatch repair gene mutation. All MSI-H colorectal carcinomas were analyzed for grade, location, and tumor histology. The utility of the revised Bethesda guidelines and published predictive pathology models for MSI-H colorectal carcinomas (PREDICT and MSPath) were evaluated. Left-sided MSI-H colorectal carcinomas were more frequently associated with LS compared with right-sided MSI-H colorectal carcinomas (12/21, 57% versus 26/129, 20%, P = .0008). There was no significant difference in histology between sporadic MSI-H and LS/probable LS-associated colorectal carcinomas except for a slightly higher proportion of sporadic MSI-H tumors demonstrating tumor-infiltrating lymphocytes (81% versus 61%, P = .015). Neither pathology predictive model identified all LS-associated colorectal carcinomas (PREDICT: 33/38, 87%; MSPath: 35/38, 92%). 12/117 (10%) MSI-H colorectal carcinomas identified in patients >60 years were LS/probable LS-associated. Our results demonstrate that models of predicting MSI-H fail to identify LS-associated colorectal carcinoma given their reliance on right-sided location. A significant proportion (32%) of LS-associated colorectal carcinoma is identified in patients >60 years. Finally, our results demonstrate similar morphologic features between LS-associated and sporadic MSI-H colorectal carcinomas. © 2013.
NASA Astrophysics Data System (ADS)
Armitage, D. M.; Bacon, D. J.; Massey-Norton, J. T.; Miller, J. M.
1980-11-01
Groundwater is attractive as a potential low temperature energy source in residential space conditioning applications. When used in conjunction with a heat pump, ground water can serve as both a heat source and a heat sink. Major hydrogeologic aspects that affect system use include groundwater temperature and availability at shallow depths as these factors influence operational efficiency. Ground water quality is considered as it affects the performance and life expectancy of the water side heat exchanger. Environmental impacts related to groundwater heat pump system use are most influenced by water use and disposal methods. In general, recharge to the subsurface is recommended. Legal restrictions on system use are often stricter at the municipal and county levels than at state and federal levels. Computer simulations indicate that under a variety of climatologic conditions, groundwater heat pumps use less energy than conventional heating and cooling equipment. Life cycle cost comparisons with conventional equipment depend on alternative system choices and well cost options included in the groundwater heat pump system.
Piekutowska-Abramczuk, Dorota; Rutyna, Rafał; Czyżyk, Elżbieta; Jurkiewicz, Elżbieta; Iwanicka-Pronicka, Katarzyna; Rokicki, Dariusz; Stachowicz, Sylwia; Strzemecka, Joanna; Guz, Wiesław; Gawroński, Michał; Kosierb, Aneta; Ligas, Joanna; Puchala, Mateusz; Drelich-Zbroja, Anna; Bednarska-Makaruk, Małgorzata; Dąbrowski, Wojciech; Ciara, Elżbieta; Książyk, Janusz B; Pronicka, Ewa
2018-02-01
Leigh syndrome (LS), subacute necrotizing encephalomyelopathy is caused by various genetic defects, including m.9185T>C MTATP6 variant. Mechanism of LS development remains unknown. We report on the acid-base status of three patients with m.9185T>C related LS. At the onset, it showed respiratory alkalosis, reflecting excessive respiration effort (hyperventilation with low pCO 2 ). In patient 1, the deterioration occurred in temporal relation to passive oxygen therapy. To the contrary, on the recovery, she demonstrated a relatively low respiratory drive, suggesting that a "hypoventilation" might be beneficial for m.9185T>C carriers. As long as circumstances of the development of LS have not been fully explained, we recommend to counteract hyperventilation and carefully dose oxygen in patients with m.9185T>C related LS.
A block-based JPEG-LS compression technique with lossless region of interest
NASA Astrophysics Data System (ADS)
Deng, Lihua; Huang, Zhenghua; Yao, Shoukui
2018-03-01
JPEG-LS lossless compression algorithm is used in many specialized applications that emphasize on the attainment of high fidelity for its lower complexity and better compression ratios than the lossless JPEG standard. But it cannot prevent error diffusion because of the context dependence of the algorithm, and have low compression rate when compared to lossy compression. In this paper, we firstly divide the image into two parts: ROI regions and non-ROI regions. Then we adopt a block-based image compression technique to decrease the range of error diffusion. We provide JPEG-LS lossless compression for the image blocks which include the whole or part region of interest (ROI) and JPEG-LS near lossless compression for the image blocks which are included in the non-ROI (unimportant) regions. Finally, a set of experiments are designed to assess the effectiveness of the proposed compression method.
Impact of age cutoffs on a lynch syndrome screening program.
Gudgeon, James M; Belnap, Thomas W; Williams, Janet L; Williams, Marc S
2013-07-01
To determine the impact of applying an age cutoff to tumor-based Lynch syndrome (LS) screening, specifically focusing on changes in relative effectiveness, efficiency, and cost. The project was undertaken to answer questions about implementation of the LS screening program in an integrated health care delivery system. Clinical data extracted from an internal cancer registry, previous modeling efforts, published literature, and gray data were used to populate decision models designed to answer questions about the impact of age cutoffs in LS screening. Patients with colorectal cancer (CRC) were stratified at 10-year intervals from ages 50 to 80 years and compared with no age cutoff. Outcomes are reported for a cohort of 325 patients screened and includes total cost to screen, LS cases present in the cutoff category, number of LS cases expected to be identified by screening, cost per LS case detected, and total number and percentage of LS cases missed. Applying an age cutoff to an LS screening program has considerable potential for decreasing total screening costs and increasing efficiency, but at a loss of effectiveness. Imposing an age cutoff of 50 years reduces the cost of the screening program to 16% of a program with no age cutoff, but at the expense of missing more than half of the cases. Failure to identify LS cases is magnified by a cascade effect in family members. The results of this analysis influenced the final policy in our system.
Cavallo, Franco; Dalmasso, Paola; Ottová-Jordan, Veronika; Brooks, Fiona; Mazur, Joanna; Välimaa, Raili; Gobina, Inese; Gaspar de Matos, Margarida; Raven-Sieberer, Ulrike
2015-04-01
Life satisfaction (LS) is an indicator which is widely used for assessing the perception of a child's feeling about his life. LS is assessed in Health Behaviour in School-aged Children via the Cantril ladder with 10 steps indicating the worst and best possible life. This range of values (0-10) was dichotomized into 'low' (0-5) vs. 'high' (6-10). Countries, age groups and genders were compared based on the odds ratio (OR) of declaring a higher LS in 2010 with respect to 2002. Analyzing the difference between 2002 and 2010, six countries from Western Europe show decreasing LS: Austria, Canada, Switzerland, Denmark, Finland and Greenland. In contrast, a group of Eastern European Countries, that is, Estonia, Croatia, Lithuania, Latvia, Russia and Ukraine, show a significant increase in LS. Data on gender and age differences confirm the lower rating of LS in girls and a decreasing rating with age. The LS scale appears to be a tool capable of discriminating the level of wellbeing of adolescent population among countries. © The Author 2015. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.
Pancreatic non-functioning neuroendocrine tumor: a new entity genetically related to Lynch syndrome
Serracant Barrera, Anna; Serra Pla, Sheila; Blázquez Maña, Carmen María; Salas, Rubén Carrera; García Monforte, Neus; Bejarano González, Natalia; Romaguera Monzonis, Andreu; Andreu Navarro, Francisco Javier; Bella Cueto, Maria Rosa
2017-01-01
Some pancreatic neuroendocrine tumors (P-NETs) are associated with hereditary syndromes. An association between Lynch syndrome (LS) and P-NETs has been suggested, however it has not been confirmed to date. We describe the first case associating LS and P-NETs. Here we report a 65-year-old woman who in the past 20 years presented two colorectal carcinomas (CRC) endometrial carcinoma (EC), infiltrating ductal breast carcinoma, small intestine adenocarcinoma, two non-functioning P-NETs and sebomatricoma. With the exception of one P-NET, all these conditions were associated with LS, as confirmed by immunohistochemistry (IHC) and polymerase chain reaction (PCR). LS is caused by a mutation of a mismatch repair (MMR) gene which leads to a loss of expression of its protein. CRC is the most common tumor, followed by EC. Pancreatic tumors have also been associated with LS. Diagnosis of LS is based on clinical criteria (Amsterdam II and Bethesda) and genetic study (MMR gene mutation). The association between LS and our patient’s tumors was confirmed by IHC (loss of expression of proteins MLH1 and its dimer PMS2) and the detection of microsatellite instability (MSI) using PCR. PMID:29184699
Dual-Pump Coherent Anti-Stokes Raman Scattering Temperature and CO2 Concentration Measurements
NASA Technical Reports Server (NTRS)
Lucht, Robert P.; Velur-Natarajan, Viswanathan; Carter, Campbell D.; Grinstead, Keith D., Jr.; Gord, James R.; Danehy, Paul M.; Fiechtner, G. J.; Farrow, Roger L.
2003-01-01
Measurements of temperature and CO2 concentration using dual-pump coherent anti-Stokes Raman scattering, (CARS) are described. The measurements were performed in laboratory flames,in a room-temperature gas cell, and on an engine test stand at the U.S. Air Force Research Laboratory, Wright-Patterson Air Force Base. A modeless dye laser, a single-mode Nd:YAG laser, and an unintensified back-illuminated charge-coupled device digital camera were used for these measurements. The CARS measurements were performed on a single-laser-shot basis. The standard deviations of the temperatures and CO2 mole fractions determined from single-shot dual-pump CARS spectra in steady laminar propane/air flames were approximately 2 and 10% of the mean values of approximately 2000 K and 0.10, respectively. The precision and accuracy of single-shot temperature measurements obtained from the nitrogen part of the dual-pump CARS system were investigated in detail in near-adiabatic hydrogen/air/CO2 flames. The precision of the CARS temperature measurements was found to be comparable to the best results reported in the literature for conventional two-laser, single-pump CARS. The application of dual-pump CARS for single-shot measurements in a swirl-stabilized combustor fueled with JP-8 was also demonstrated.
Heshmat, Ramin; Qorbani, Mostafa; Safiri, Saeid; Eslami-Shahr Babaki, Amir; Matin, Nassim; Motamed-Gorji, Nazgol; Motlagh, Mohammad-Esmaeil; Djalalinia, Shirin; Ardalan, Gelayol; Mansourian, Morteza; Asayesh, Hamid; Kelishadi, Roya
2017-01-01
Objective To assess the joint association of passive and active smoking with self-rated health and life satisfaction among Iranian children and adolescents. Methods Using a multistage random cluster sampling method, a representative sample of 14 880 school students were selected from urban and rural areas of 30 provinces of Iran. Data were gathered using a questionnaire, a weight scale and metre. Participants were classified into four groups based on their smoking patterns: ‘non-smoker’, ‘only active smoker’, ‘only passive smoker’ and ‘active and passive smoker’. Life satisfaction (LS) and self-rated health (SRH) were assessed by self-administered validated questionnaires based on the WHO-Global School-based student Health Survey (WHO-GSHS). Data were analysed using a t-test, χ2 test and multiple logistic regression. Results A total of 13 486 individuals (6640 girls and 6846 boys) out of 14 880 invited participated in the study (response rate 90.6%). LS and good SRH showed linearly negative associations with smoking status in both sexes. The proportions of LS and SRH categories were significantly different among all subsets of smoking status. Those classified as ‘non-smokers’ had the highest proportions of LS and good SRH, followed by ‘only passive smokers’ and ‘only active smokers’, while those with ‘active and passive smoking’ had the lowest proportions of LS and good SRH. In a multivariate model, students in the ‘active and passive smoking’ group had lower odds of LS (OR 0.43; 95% CI 0.32 to 0.57) and good SRH (OR 0.51; 95% CI 0.38 to 0.68) than those in the ‘non-smoker’ group. Students in the ‘only passive smoker’ group also had lower odds of LS (OR 0.75; 95% CI 0.67 to 0.83) and good SRH (OR 0.72; 95% CI 0.66 to 0.80) compared with the ‘non-smoker’ group. Conclusions Adolescents with different smoking habits and exposure patterns have poorer SRH and LS than non-smokers. Both active and passive smoking status could affect LS and SRH in adolescents. Therefore, smoking prevention strategies should be considered as a health priority in school health services for promoting psychological well-being in children and adolescents. PMID:28196944
Snowsill, Tristan; Coelho, Helen; Huxley, Nicola; Jones-Hughes, Tracey; Briscoe, Simon; Frayling, Ian M; Hyde, Chris
2017-09-01
Inherited mutations in deoxyribonucleic acid (DNA) mismatch repair (MMR) genes lead to an increased risk of colorectal cancer (CRC), gynaecological cancers and other cancers, known as Lynch syndrome (LS). Risk-reducing interventions can be offered to individuals with known LS-causing mutations. The mutations can be identified by comprehensive testing of the MMR genes, but this would be prohibitively expensive in the general population. Tumour-based tests - microsatellite instability (MSI) and MMR immunohistochemistry (IHC) - are used in CRC patients to identify individuals at high risk of LS for genetic testing. MLH1 (MutL homologue 1) promoter methylation and BRAF V600E testing can be conducted on tumour material to rule out certain sporadic cancers. To investigate whether testing for LS in CRC patients using MSI or IHC (with or without MLH1 promoter methylation testing and BRAF V600E testing) is clinically effective (in terms of identifying Lynch syndrome and improving outcomes for patients) and represents a cost-effective use of NHS resources. Systematic reviews were conducted of the published literature on diagnostic test accuracy studies of MSI and/or IHC testing for LS, end-to-end studies of screening for LS in CRC patients and economic evaluations of screening for LS in CRC patients. A model-based economic evaluation was conducted to extrapolate long-term outcomes from the results of the diagnostic test accuracy review. The model was extended from a model previously developed by the authors. Ten studies were identified that evaluated the diagnostic test accuracy of MSI and/or IHC testing for identifying LS in CRC patients. For MSI testing, sensitivity ranged from 66.7% to 100.0% and specificity ranged from 61.1% to 92.5%. For IHC, sensitivity ranged from 80.8% to 100.0% and specificity ranged from 80.5% to 91.9%. When tumours showing low levels of MSI were treated as a positive result, the sensitivity of MSI testing increased but specificity fell. No end-to-end studies of screening for LS in CRC patients were identified. Nine economic evaluations of screening for LS in CRC were identified. None of the included studies fully matched the decision problem and hence a new economic evaluation was required. The base-case results in the economic evaluation suggest that screening for LS in CRC patients using IHC, BRAF V600E and MLH1 promoter methylation testing would be cost-effective at a threshold of £20,000 per quality-adjusted life-year (QALY). The incremental cost-effectiveness ratio for this strategy was £11,008 per QALY compared with no screening. Screening without tumour tests is not predicted to be cost-effective. Most of the diagnostic test accuracy studies identified were rated as having a risk of bias or were conducted in unrepresentative samples. There was no direct evidence that screening improves long-term outcomes. No probabilistic sensitivity analysis was conducted. Systematic review evidence suggests that MSI- and IHC-based testing can be used to identify LS in CRC patients, although there was heterogeneity in the methods used in the studies identified and the results of the studies. There was no high-quality empirical evidence that screening improves long-term outcomes and so an evidence linkage approach using modelling was necessary. Key determinants of whether or not screening is cost-effective are the accuracy of tumour-based tests, CRC risk without surveillance, the number of relatives identified for cascade testing, colonoscopic surveillance effectiveness and the acceptance of genetic testing. Future work should investigate screening for more causes of hereditary CRC and screening for LS in endometrial cancer patients. This study is registered as PROSPERO CRD42016033879. The National Institute for Health Research Health Technology Assessment programme.
Pulse-actuated fuel-injection spark plug
Murray, Ian; Tatro, Clement A.
1978-01-01
A replacement spark plug for reciprocating internal combustion engines that functions as a fuel injector and as a spark plug to provide a "stratified-charge" effect. The conventional carburetor is retained to supply the main fuel-air mixture which may be very lean because of the stratified charge. The replacement plug includes a cylindrical piezoelectric ceramic which contracts to act as a pump whenever an ignition pulse is applied to a central rod through the ceramic. The rod is hollow at its upper end for receiving fuel, it is tapered along its lower length to act as a pump, and it is flattened at its lower end to act as a valve for fuel injection from the pump into the cylinder. The rod also acts as the center electrode of the plug, with the spark jumping from the plug base to the lower end of the rod to thereby provide spark ignition that has inherent proper timing with the fuel injection.
Huebner, K L; Kunkel, A K; McConnel, C S; Callan, R J; Dinsmore, R P; Caixeta, L S
2017-05-01
Pain management during and following disbudding procedures has been studied extensively, though few studies have evaluated wound healing following cautery disbudding in dairy calves. The purpose of this study was to observe wound healing following cautery disbudding with or without treatment using a topical aluminum-based aerosol bandage (ALU) in preweaned dairy calves. Dairy calves were disbudded within the first 3 wk of life using a standard cautery disbudding protocol. The ALU treatment was randomly allocated to the right or left horn bud within each animal. The outcomes measured were lesion score (LS) and wound diameter (WD). The LS was evaluated on a scale of 1 to 3, with LS = 1 representing normal healing without a scab or exudate, LS = 2 having the presence of a scab, and LS = 3 showing the presence of wound exudate. Lesion score and WD were evaluated on a weekly basis following dehorning for 3 wk. A total of 209 animals completed the study. No difference was observed in LS between groups during the first 2 wk postdisbudding, but the proportion of LS = 3 on wk 3 postdisbudding was greater for the control group when compared with ALU (17 vs. 8%, respectively). During wk 1 and 2 postdisbudding, the odds of having delayed healing, or a LS ≥2, were similar for both groups. However, the odds tended to be different at wk 3 postdisbudding with control disbudding sites being 1.42 times more likely to have delayed healing than ALU. In wk 3, WD was 1 mm smaller in the treatment group compared with the control, and treatment decreased diameter over time compared with controls. Overall, once abnormal wound healing was observed, the likelihood of having abnormal wound healing the following week was increased. However, treatment with ALU diminished this effect on delayed healing during the follow-up period. Based on these results, the use of ALU improved wound healing following cautery disbudding of preweaned dairy calves. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Wu, Chunhung
2016-04-01
Few researches have discussed about the applicability of applying the statistical landslide susceptibility (LS) model for extreme rainfall-induced landslide events. The researches focuses on the comparison and applicability of LS models based on four methods, including landslide ratio-based logistic regression (LRBLR), frequency ratio (FR), weight of evidence (WOE), and instability index (II) methods, in an extreme rainfall-induced landslide cases. The landslide inventory in the Chishan river watershed, Southwestern Taiwan, after 2009 Typhoon Morakot is the main materials in this research. The Chishan river watershed is a tributary watershed of Kaoping river watershed, which is a landslide- and erosion-prone watershed with the annual average suspended load of 3.6×107 MT/yr (ranks 11th in the world). Typhoon Morakot struck Southern Taiwan from Aug. 6-10 in 2009 and dumped nearly 2,000 mm of rainfall in the Chishan river watershed. The 24-hour, 48-hour, and 72-hours accumulated rainfall in the Chishan river watershed exceeded the 200-year return period accumulated rainfall. 2,389 landslide polygons in the Chishan river watershed were extracted from SPOT 5 images after 2009 Typhoon Morakot. The total landslide area is around 33.5 km2, equals to the landslide ratio of 4.1%. The main landslide types based on Varnes' (1978) classification are rotational and translational slides. The two characteristics of extreme rainfall-induced landslide event are dense landslide distribution and large occupation of downslope landslide areas owing to headward erosion and bank erosion in the flooding processes. The area of downslope landslide in the Chishan river watershed after 2009 Typhoon Morakot is 3.2 times higher than that of upslope landslide areas. The prediction accuracy of LS models based on LRBLR, FR, WOE, and II methods have been proven over 70%. The model performance and applicability of four models in a landslide-prone watershed with dense distribution of rainfall-induced landslide are interesting and meaningful. Eight landslide-related factors, including elevation, slope, aspect, geology, accumulated rainfall during 2009 Typhoon Morakot, landuse, distance to the fault, and distance to the rivers, were considered in this research. The research builds and compares the difference of the LS maps based on four methods. The average LS value from each method is 0.27 for LRBLR, 0.368 for FR, 0.553 for WOE, and 0.498 for II. The correlation analysis was conducted to identify similarities between the four LS maps. The correlation coefficients are 0.913, 0.829, 0.930, 0.756, 0.729, and 0.652 for the LRBLR vs FR, LRBLR vs WOE, FR vs WOE, LRBLR vs II, FR vs II, and WOE vs II. The research compares the model performance of four LS maps by calculating the AUC value (area under the ROC curve) and ACR value (average correct-predicted ratio). The AUC values of LS maps based on LRBLR, FR, WOE, and II methods are 0.819, 0.819, 0.822 and 0.785. The ACR values of LS maps based on LRBLR, FR, WOE, and II methods are 75.1%, 73.7%, 68.4%, and 64.2%. The results indicate that the model performance based on LRBLR method in an extreme rainfall-landslide event is better than that based on the other three methods.
A cohort of children with type 1 diabetes in Greece: predictors of direct costs of care.
Karachaliou, Feneli; Athanasakis, Konstantinos; Tsentidis, Charalabos; Soldatou, Alexandra; Simatos, George; Kyriopoulos, John; Michalakos, Stefanos; Karavanaki, Kyriaki
2017-08-01
To examine the predictors of direct costs of pediatric type 1 diabetes (T1D) in a hospital-based outpatient clinic in Greece. The outpatient records of 89 children and adolescents (mean age: 12.05 ± 5.15 y) with T1D followed in the Second Department of Pediatrics, University of Athens Medical School, were analyzed. The mean ± SD diabetes duration was 4.9 ± 3.88 y (range: 0.25-17) and glycated hemoglobin (HbA1c) was 8.2 ± 1.09% (66 ± 11.9 mmol/mol). A total of 80% of patients were on multiple daily injections regimen, 10% on pump therapy, and 10% on conventional regimen. Total direct costs per patient-year (ppy) were estimated at €2.712 [95% confidence interval (CI): 2.468-2.956]. Supply costs accounted for 73.7% of total costs and were the highest for pump therapy (P < .001). Multivariate linear regression analysis showed that costs were significantly higher for children (1) on multiple daily injections or pump therapy (r = 0.364, P < .001), (2) of older age (r = 0.25, P < .001) and (3) higher daily insulin dose (r = 0.46, P < .001). Patients on pump therapy had significantly higher costs €5.538 (95%CI 4480-6597) compared with patients on multiple daily injections €2.447 (95% CI 2320-2574) and conventional regimen €1.978.5 (95%CI 1682-2275) (P = .0001). Patients on pump therapy had better glycemic control compared with all other patients [HbA1c (mean ± SD): 7.2% ± 1.0 vs 8.3% ±1.5, P = .039]. The total T1D cost in this cohort of Greek children was €2712 ppy. The main factor that predicted direct cost was the use of pump. However, pump therapy was associated with better glycaemic control, which may decrease the risk of total long-term diabetes care cost. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Synergies of solar energy use in the desalination of seawater: A case study in northern Chile
NASA Astrophysics Data System (ADS)
Servert, Jorge F.; Cerrajero, Eduardo; Fuentealba, Edward L.
2016-05-01
The mining industry is a great consumer of water for hydrometallurgical processes. Despite the efforts in minimizing the use of fresh water through reuse, recycling and process intensification, water demand for mining is expected to rise a 40% from 2013 to 2020. For seawater to be an alternative to groundwater, it must be pumped up to the mine (thousands of meters uphill) and desalinated. These processes require intensive energy and investment in desalination and piping/pumping facilities. A conventional solution for this process would be desalination by reverse osmosis at sea level, powered by electricity from the grid, and further pumping of the desalinated water uphill. This paper compares the feasibility of two solar technologies versus the "conventional" option. LCOW (Levelized Cost of Water) was used as a comparative indicator among the studied solutions, with values for a lifetime of 10, 15, 20 and 25 years, calculated using a real discount rate equal to 12%. The LCOW is lower in all cases for the RO + grid solution. The cost of desalination, ignoring the contribution of pumping, is similar for the three technologies from twenty years of operation. The use of solar energy to desalinate sea water for consumption in the mines of the Atacama region is technically feasible. However, due to the extra costs from pumping whole seawater, and not just the desalinated water, solar solutions are less competitive than the conventional process.
Zhong, Z W; Wu, R G; Wang, Z P; Tan, H L
2015-09-01
Conventional microfluidic devices are typically complex and expensive. The devices require the use of pneumatic control systems or highly precise pumps to control the flow in the devices. This work investigates an alternative method using paper based microfluidic devices to replace conventional microfluidic devices. Size based separation and extraction experiments conducted were able to separate free dye from a mixed protein and dye solution. Experimental results showed that pure fluorescein isothiocyanate could be separated from a solution of mixed fluorescein isothiocyanate and fluorescein isothiocyanate labeled bovine serum albumin. The analysis readings obtained from a spectrophotometer clearly show that the extracted tartrazine sample did not contain any amount of Blue-BSA, because its absorbance value was 0.000 measured at a wavelength of 590nm, which correlated to Blue-BSA. These demonstrate that paper based microfluidic devices, which are inexpensive and easy to implement, can potentially replace their conventional counterparts by the use of simple geometry designs and the capillary action. These findings will potentially help in future developments of paper based microfluidic devices. Copyright © 2015 Elsevier B.V. All rights reserved.
CHEMICAL ENHANCEMENTS TO PUMP-AND-TREAT REMEDIATION
Conventional pump-and-treat technologies are among the most widely used systems for the remediation of contaminated ground-water. ithin recent years it has become recognized that these systems can require protracted periods of time to make significant reductions in the quantity o...
A novel compact dual-wideband BPF with multiple transmission zeros and super wide upper stopband
NASA Astrophysics Data System (ADS)
Mirzaee, Milad; Nosrati, Mehdi
2013-05-01
In this article, a novel miniaturised dual-wideband bandpass filter (DWB-BPF) based on two different resonators including a quasi-spiral loaded multiple-mode resonator (QSL-MMR) and L-shaped transmission line (LS-TL) is presented. At the first step, in order to design a single wideband BPF filter with controllable transmission zeros near the centre frequency, the open circuit impedance parameter of quasi-spiral loaded resonator Z21 is determined in terms of ABCD matrix. Then an equivalent circuit model of the proposed structure is derived and the impedance characteristic and electrical length of LS-TLs to achieve a DWB-BPF with excellent selectivity are calculated through even- and odd-mode analysis. The proposed filter possesses both compact and simple structure as well as two wide passbands with fractional bandwidth (FBW) of 70% and 22.8% for its first and second passbands, respectively. The proposed technique creates two transmission zeros at the lower and upper stopbands of each passband resulting in a very sharp roll-off accompanied by a wide stopband. Notably, the circuit size is reduced and the bandwidth is enhanced in comparison with its conventional counterparts. The theoretical performance of the filter is verified by the experimental one where a good agreement is reported between them.
Evaluation of sewage sludge incineration ash as a potential land reclamation material.
Lin, Wenlin Yvonne; Ng, Wei Cheng; Wong, Belinda Shu Ee; Teo, Serena Lay-Ming; Sivananthan, Gayathiri D/O; Baeg, Gyeong Hun; Ok, Yong Sik; Wang, Chi-Hwa
2018-05-23
This study evaluated the potential of utilising sewage sludge incineration ash as a land reclamation material. Toxicity assessment of the leachate of the ash was carried out for both terrestrial and marine organisms. Both the fruit fly Drosophila melanogaster and barnacle Amphibalanus amphitrite showed that both bottom and fly ash leached at liquid-to-solid (L/S) ratio 5 did not substantially affect viabilities. The leachate carried out at L/S 10 was compared to the European Waste Acceptance Criteria and the sewage sludge ashes could be classified as non-hazardous waste. The geotechnical properties of the sewage sludge ash were studied and compared to sand, a conventional land reclamation material, for further evaluation of its potential as a land reclamation material. It was found from direct shear test that both bottom and fly ashes displayed similar and comparable shear strength to that of typical compacted sandy soil based on the range of internal friction angle obtained. However, the consolidation profile of bottom ash was significantly different from sand, while that of fly ash was more similar to sand. Our study showed that the sewage sludge ash has the potential to be used as a land reclamation material. Copyright © 2018 Elsevier B.V. All rights reserved.
Biodegradation test of SPS-LS blends as polymer electrolyte membrane fuel cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Putri, Zufira, E-mail: zufira.putri@gmail.com, E-mail: arcana@chem.itb.ac.id; Arcana, I Made, E-mail: zufira.putri@gmail.com, E-mail: arcana@chem.itb.ac.id
Sulfonated polystyrene (SPS) can be applied as a proton exchange membrane fuel cell due to its fairly good chemical stability. In order to be applied as polymer electrolyte membrane fuel cells (PEMFCs), membrane polymer should have a good ionic conductivity, high proton conductivity, and high mechanical strength. Lignosulfonate (LS) is a complex biopolymer which has crosslinks and sulfonate groups. SPS-LS blends with addition of SiO{sub 2} are used to increase the proton conductivity and to improve the mechanical properties and thermal stability. However, the biodegradation test of SPS-LS blends is required to determine whether the application of these membranes tomore » be applied as an environmentally friendly membrane. In this study, had been done the synthesis of SPS, biodegradability test of SPS-LS blends with variations of LS and SiO{sub 2} compositions. The biodegradation test was carried out in solid medium of Luria Bertani (LB) with an activated sludge used as a source of microorganism at incubation temperature of 37°C. Based on the results obtained indicated that SPS-LS-SiO{sub 2} blends are more decomposed by microorganism than SPS-LS blends. This result is supported by analysis of weight reduction percentage, functional groups with Fourier Transform Infrared (FTIR) Spectroscopy, and morphological surface with Scanning Electron Microscopy (SEM)« less
Thin film DNA-complex-based dye lasers fabricated by immersion and conventional processes
NASA Astrophysics Data System (ADS)
Kawabe, Yutaka; Suzuki, Yuki
2017-08-01
DNA based thin film dye laser is one of promising optical devices for future technology. Laser oscillation and amplified spontaneous emission (ASE) were demonstrated by hemicyanine-doped DNA complex films prepared with `immersion method' as well as those made by a conventional way. In the immersion process, DNA-surfactant complex films were stained by immersion into an acetone solution including the dyes. In this study, three types of hemicyanines were incorporated with both methods, and laser oscillation was achieved with optically induced population grating formed in all of the complex films. The laser threshold values for six cases ranged in 0.07 - 0.18 mJ/cm2 , which was close to the best values made in DNA complex matrices. Continual pumping showed that laser oscillation persisted for 4 - 10 minutes. Immersion process gave superior laser capability especially for output efficiency over the conventional counterparts.
THESEUS: maximum likelihood superpositioning and analysis of macromolecular structures
Theobald, Douglas L.; Wuttke, Deborah S.
2008-01-01
Summary THESEUS is a command line program for performing maximum likelihood (ML) superpositions and analysis of macromolecular structures. While conventional superpositioning methods use ordinary least-squares (LS) as the optimization criterion, ML superpositions provide substantially improved accuracy by down-weighting variable structural regions and by correcting for correlations among atoms. ML superpositioning is robust and insensitive to the specific atoms included in the analysis, and thus it does not require subjective pruning of selected variable atomic coordinates. Output includes both likelihood-based and frequentist statistics for accurate evaluation of the adequacy of a superposition and for reliable analysis of structural similarities and differences. THESEUS performs principal components analysis for analyzing the complex correlations found among atoms within a structural ensemble. PMID:16777907
Ultra high vacuum pumping system and high sensitivity helium leak detector
Myneni, G.R.
1997-12-30
An improved helium leak detection method and apparatus are disclosed which increase the leak detection sensitivity to 10{sup {minus}13} atm cc/s. The leak detection sensitivity is improved over conventional leak detectors by completely eliminating the use of o-rings, equipping the system with oil-free pumping systems, and by introducing measured flows of nitrogen at the entrances of both the turbo pump and backing pump to keep the system free of helium background. The addition of dry nitrogen flows to the system reduces back streaming of atmospheric helium through the pumping system as a result of the limited compression ratios of the pumps for helium. 2 figs.
Rybak, Christina; Hall, Michael J
2011-11-01
Colorectal cancer (CRC) risk assessment involves the evaluation of an individual's personal and family history for characteristics of an inherited susceptibility to develop CRC. Lynch syndrome (LS), or hereditary nonpolyposis colorectal cancer, is the most common cause of hereditary CRC, underlying 2% to 3% of patients with newly diagnosed (incident) CRC. Risk assessment for LS is complex, and the interpretation of the many available tests can be challenging even for the genetics specialist. A move toward universal (reflex) LS screening for mismatch repair in all patients with incident CRC supports the importance of improving the awareness and understanding of LS testing, teaching rational testing approaches, and honing interpretive skills among cancer care providers. This article reviews important clinical features of LS genetic evaluation using 3 pedigree-based case examples from the Fox Chase Cancer Center Gastrointestinal Risk Assessment Clinic.
Leigh Syndrome in Childhood: Neurologic Progression and Functional Outcome.
Lee, Jin Sook; Kim, Hunmin; Lim, Byung Chan; Hwang, Hee; Choi, Jieun; Kim, Ki Joong; Hwang, Yong Seung; Chae, Jong Hee
2016-04-01
Few studies have analyzed the clinical course and functional outcome in Leigh syndrome (LS). The aim of this study was to determine the clinical, radiological, biochemical, and genetic features of patients with LS, and identify prognostic indicators of the disease progression and neurological outcome. Thirty-nine patients who had been diagnosed with LS at the Seoul National University Children's Hospital were included. Their medical records, neuroimaging findings, and histological/biochemical findings of skeletal muscle specimens were reviewed. Targeted sequencing of mitochondrial DNA was performed based on mitochondrial respiratory chain (MRC) enzyme defects. Isolated complex I deficiency was the most frequently observed MRC defect (in 42% of 38 investigated patients). Mitochondrial DNA mutations were identified in 11 patients, of which 81.8% were MT-ND genes. The clinical outcome varied widely, from independent daily activity to severe disability. Poor functional outcomes and neurological deterioration were significantly associated with early onset (before an age of 1 year) and the presence of other lesions additional to basal ganglia involvement in the initial neuroimaging. The neurological severity and outcome of LS may vary widely and be better than those predicted based on previous studies. We suggest that age at onset and initial neuroimaging findings are prognostic indicators in LS.
Joelsson, Adam C; Terkhorn, Shawn P; Brown, Ashley S; Puri, Amrita; Pascal, Benjamin J; Gaudioso, Zara E; Siciliano, Nicholas A
2017-09-01
Veriflow® Listeria species (Veriflow LS) is a molecular-based assay for the presumptive detection of Listeria spp. from environmental surfaces (stainless steel, sealed concrete, plastic, and ceramic tile) and ready-to-eat (RTE) food matrixes (hot dogs and deli meat). The assay utilizes a PCR detection method coupled with a rapid, visual, flow-based assay that develops in 3 min post-PCR amplification and requires only a 24 h enrichment for maximum sensitivity. The Veriflow LS system eliminates the need for sample purification, gel electrophoresis, or fluorophore-based detection of target amplification and does not require complex data analysis. This Performance Tested MethodSM validation study demonstrated the ability of the Veriflow LS assay to detect low levels of artificially inoculated Listeria spp. in six distinct environmental and food matrixes. In each unpaired reference comparison study, probability of detection analysis indicated that there was no significant difference between the Veriflow LS method and the U.S. Department of Agriculture Food Safety and Inspection Service Microbiology Laboratory Guide Chapter 8.08 reference method. Fifty-one strains of various Listeria spp. were detected in the inclusivity study, and 35 nonspecific organisms went undetected in the exclusivity study. The study results show that the Veriflow LS is a sensitive, selective, and robust assay for the presumptive detection of Listeria spp. sampled from environmental surfaces (stainless steel, sealed concrete, plastic, and ceramic tile) and RTE food matrixes (hot dogs and deli meat).
Design and physical features of inductive coaxial copper vapor lasers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Batenin, V. M.; Kazaryan, M. A.; Karpukhin, V. T.
A physical model of a copper vapor laser pumped by a pulse-periodic inductive (electrodeless) discharge is considered. The feasibility of efficient laser pumping by an inductive discharge and reaching high output parameters comparable to those of conventional copper vapor lasers pumped by a longitudinal electrode discharge is demonstrated. The design and physical features of an inductive copper vapor laser with an annular working volume are discussed.
High-gain mid-infrared optical-parametric generation pumped by microchip laser.
Ishizuki, Hideki; Taira, Takunori
2016-01-25
High-gain mid-infrared optical-parametric generation was demonstrated by simple single-pass configuration using PPMgLN devices pumped by giant-pulse microchip laser. Effective mid-infrared wavelength conversion with 1 mJ output energy from 2.4 mJ pumping using conventional PPMgLN could be realized. Broadband optical-parametric generation from 1.7 to 2.6 µm could be also measured using chirped PPMgLN.
Wong, Wicger K H; Leung, Lucullus H T; Kwong, Dora L W
2016-01-01
To evaluate and optimize the parameters used in multiple-atlas-based segmentation of prostate cancers in radiation therapy. A retrospective study was conducted, and the accuracy of the multiple-atlas-based segmentation was tested on 30 patients. The effect of library size (LS), number of atlases used for contour averaging and the contour averaging strategy were also studied. The autogenerated contours were compared with the manually drawn contours. Dice similarity coefficient (DSC) and Hausdorff distance were used to evaluate the segmentation agreement. Mixed results were found between simultaneous truth and performance level estimation (STAPLE) and majority vote (MV) strategies. Multiple-atlas approaches were relatively insensitive to LS. A LS of ten was adequate, and further increase in the LS only showed insignificant gain. Multiple atlas performed better than single atlas for most of the time. Using more atlases did not guarantee better performance, with five atlases performing better than ten atlases. With our recommended setting, the median DSC for the bladder, rectum, prostate, seminal vesicle and femurs was 0.90, 0.77, 0.84, 0.56 and 0.95, respectively. Our study shows that multiple-atlas-based strategies have better accuracy than single-atlas approach. STAPLE is preferred, and a LS of ten is adequate for prostate cases. Using five atlases for contour averaging is recommended. The contouring accuracy of seminal vesicle still needs improvement, and manual editing is still required for the other structures. This article provides a better understanding of the influence of the parameters used in multiple-atlas-based segmentation of prostate cancers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turbak, S. C.; Reichle, D. R.; Shriner, C. R.
1981-01-01
This document presents a state-of-the-art review of literature concerning turbine-related fish mortality. The review discusses conventional and, to a lesser degree, pumped-storage (reversible) hydroelectric facilities. Much of the research on conventional facilities discussed in this report deals with studies performed in the Pacific Northwest and covers both prototype and model studies. Research conducted on Kaplan and Francis turbines during the 1950s and 1960s has been extensively reviewed and is discussed. Very little work on turbine-related fish mortality has been undertaken with newer turbine designs developed for more modern small-scale hydropower facilities; however, one study on a bulb unit (Kaplan runner)more » has recently been released. In discussing turbine-related fish mortality at pumped-storage facilities, much of the literature relates to the Ludington Pumped Storage Power Plant. As such, it is used as the principal facility in discussing research concerning pumped storage.« less
The Möbius domain wall fermion algorithm
NASA Astrophysics Data System (ADS)
Brower, Richard C.; Neff, Harmut; Orginos, Kostas
2017-11-01
We present a review of the properties of generalized domain wall Fermions, based on a (real) Möbius transformation on the Wilson overlap kernel, discussing their algorithmic efficiency, the degree of explicit chiral violations measured by the residual mass (mres) and the Ward-Takahashi identities. The Möbius class interpolates between Shamir's domain wall operator and Boriçi's domain wall implementation of Neuberger's overlap operator without increasing the number of Dirac applications per conjugate gradient iteration. A new scaling parameter (α) reduces chiral violations at finite fifth dimension (Ls) but yields exactly the same overlap action in the limit Ls → ∞. Through the use of 4d Red/Black preconditioning and optimal tuning for the scaling α(Ls) , we show that chiral symmetry violations are typically reduced by an order of magnitude at fixed Ls. We argue that the residual mass for a tuned Möbius algorithm with α = O(1 /Lsγ) for γ < 1 will eventually fall asymptotically as mres = O(1 /Ls1+γ) in the case of a 5D Hamiltonian with out a spectral gap.
Online Least Squares One-Class Support Vector Machines-Based Abnormal Visual Event Detection
Wang, Tian; Chen, Jie; Zhou, Yi; Snoussi, Hichem
2013-01-01
The abnormal event detection problem is an important subject in real-time video surveillance. In this paper, we propose a novel online one-class classification algorithm, online least squares one-class support vector machine (online LS-OC-SVM), combined with its sparsified version (sparse online LS-OC-SVM). LS-OC-SVM extracts a hyperplane as an optimal description of training objects in a regularized least squares sense. The online LS-OC-SVM learns a training set with a limited number of samples to provide a basic normal model, then updates the model through remaining data. In the sparse online scheme, the model complexity is controlled by the coherence criterion. The online LS-OC-SVM is adopted to handle the abnormal event detection problem. Each frame of the video is characterized by the covariance matrix descriptor encoding the moving information, then is classified into a normal or an abnormal frame. Experiments are conducted, on a two-dimensional synthetic distribution dataset and a benchmark video surveillance dataset, to demonstrate the promising results of the proposed online LS-OC-SVM method. PMID:24351629
Online least squares one-class support vector machines-based abnormal visual event detection.
Wang, Tian; Chen, Jie; Zhou, Yi; Snoussi, Hichem
2013-12-12
The abnormal event detection problem is an important subject in real-time video surveillance. In this paper, we propose a novel online one-class classification algorithm, online least squares one-class support vector machine (online LS-OC-SVM), combined with its sparsified version (sparse online LS-OC-SVM). LS-OC-SVM extracts a hyperplane as an optimal description of training objects in a regularized least squares sense. The online LS-OC-SVM learns a training set with a limited number of samples to provide a basic normal model, then updates the model through remaining data. In the sparse online scheme, the model complexity is controlled by the coherence criterion. The online LS-OC-SVM is adopted to handle the abnormal event detection problem. Each frame of the video is characterized by the covariance matrix descriptor encoding the moving information, then is classified into a normal or an abnormal frame. Experiments are conducted, on a two-dimensional synthetic distribution dataset and a benchmark video surveillance dataset, to demonstrate the promising results of the proposed online LS-OC-SVM method.
2016-08-04
BAllistic SImulation Method for Lithium Ion Batteries (BASIMLIB) using Thick Shell Composites (TSC) in LS-DYNA Venkatesh Babu, Dr. Matt Castanier, Dr...Objective • Objective and focus of this work is to develop a – Robust simulation methodology to model lithium - ion based batteries in its module and full...unlimited Lithium Ion Phosphate (LiFePO4) battery cell, module and pack was modeled in LS-DYNA using both Thin Shell Layer (TSL) and Thick Shell
Cong, Juan; Wang, Zhibin; Jin, Hong; Wang, Wugang; Gong, Kun; Meng, Yuanyuan; Lee, Yong
2016-11-10
The myocardial wall of the left ventricle is a complex, multilayered structure and is not homogenous. The aim of this study was to determine longitudinal strain (LS) in the three myocardial layers in normal pregnant women according to gestation proceedings. The advanced two-dimensional speckle tracking echocardiography (2D STE) was performed on 62 women during each pregnancy trimester and 6 to 9 weeks after delivery, while 30 age-matched, healthy, nonpregnant women served as controls. LS on endocardial, mid-myocardial and epicardial layers at 18 cardiac segments were measured. As gestation proceeded, all of layer-specific LS and global LS progressively decreased, which subsequently recovered postpartum (P < 0.05), and the LS gradient between inner and outer myocardium became greater, which reached its maximum in the late pregnancy. Peak systolic LS was the highest at endocardium and the lowest at epicardium, while the highest at the apical level and the lowest at the base (P < 0.05). In the early pregnancy and postpartum, LS at basal level was homogenous, meanwhile layer-specific LS showed significant differences at mid-ventricular and apical level throughout the progress of normal pregnancy (P < 0.05). Using 2D STE, three-layer assessment of LS can be performed in pregnant women and shall give us new insights into the quantitative analysis of global and regional LV function during pregnancy. Future studies on the detection of pregnancy related heart disease would require these parameters as reference values for each time point of a normal pregnancy.
Ghafouri, Hamidreza; Ranjbar, Mohsen; Sakhteman, Amirhossein
2017-08-01
A great challenge in medicinal chemistry is to develop different methods for structural design based on the pattern of the previously synthesized compounds. In this study two different QSAR methods were established and compared for a series of piperidine acetylcholinesterase inhibitors. In one novel approach, PC-LS-SVM and PLS-LS-SVM was used for modeling 3D interaction descriptors, and in the other method the same nonlinear techniques were used to build QSAR equations based on field descriptors. Different validation methods were used to evaluate the models and the results revealed the more applicability and predictive ability of the model generated by field descriptors (Q 2 LOO-CV =1, R 2 ext =0.97). External validation criteria revealed that both methods can be used in generating reasonable QSAR models. It was concluded that due to ability of interaction descriptors in prediction of binding mode, using this approach can be implemented in future 3D-QSAR softwares. Copyright © 2017 Elsevier Ltd. All rights reserved.
Lamb Wave Damage Quantification Using GA-Based LS-SVM.
Sun, Fuqiang; Wang, Ning; He, Jingjing; Guan, Xuefei; Yang, Jinsong
2017-06-12
Lamb waves have been reported to be an efficient tool for non-destructive evaluations (NDE) for various application scenarios. However, accurate and reliable damage quantification using the Lamb wave method is still a practical challenge, due to the complex underlying mechanism of Lamb wave propagation and damage detection. This paper presents a Lamb wave damage quantification method using a least square support vector machine (LS-SVM) and a genetic algorithm (GA). Three damage sensitive features, namely, normalized amplitude, phase change, and correlation coefficient, were proposed to describe changes of Lamb wave characteristics caused by damage. In view of commonly used data-driven methods, the GA-based LS-SVM model using the proposed three damage sensitive features was implemented to evaluate the crack size. The GA method was adopted to optimize the model parameters. The results of GA-based LS-SVM were validated using coupon test data and lap joint component test data with naturally developed fatigue cracks. Cases of different loading and manufacturer were also included to further verify the robustness of the proposed method for crack quantification.
Lamb Wave Damage Quantification Using GA-Based LS-SVM
Sun, Fuqiang; Wang, Ning; He, Jingjing; Guan, Xuefei; Yang, Jinsong
2017-01-01
Lamb waves have been reported to be an efficient tool for non-destructive evaluations (NDE) for various application scenarios. However, accurate and reliable damage quantification using the Lamb wave method is still a practical challenge, due to the complex underlying mechanism of Lamb wave propagation and damage detection. This paper presents a Lamb wave damage quantification method using a least square support vector machine (LS-SVM) and a genetic algorithm (GA). Three damage sensitive features, namely, normalized amplitude, phase change, and correlation coefficient, were proposed to describe changes of Lamb wave characteristics caused by damage. In view of commonly used data-driven methods, the GA-based LS-SVM model using the proposed three damage sensitive features was implemented to evaluate the crack size. The GA method was adopted to optimize the model parameters. The results of GA-based LS-SVM were validated using coupon test data and lap joint component test data with naturally developed fatigue cracks. Cases of different loading and manufacturer were also included to further verify the robustness of the proposed method for crack quantification. PMID:28773003
NASA Astrophysics Data System (ADS)
Thapa, Rajesh; Rhonehouse, Dan; Nguyen, Dan; Wiersma, Kort; Smith, Chris; Zong, Jie; Chavez-Pirson, Arturo
2013-10-01
Mid-infrared sources are a key enabling technology for various applications such as remote chemical sensing, defense communications and countermeasures, and bio-photonic diagnostics and therapeutics. Conventional mid-IR sources include optical parametric amplifiers, quantum cascade lasers, synchrotron and free electron lasers. An all-fiber approach to generate a high power, single mode beam with extremely wide (1μm-5μm) and simultaneous wavelength coverage has significant advantages in terms of reliability (no moving parts or alignment), room temperature operation, size, weight, and power efficiency. Here, we report single mode, high power extended wavelength coverage (1μm to 5μm) supercontinuum generation using a tellurite-based dispersion managed nonlinear fiber and an all-fiber based short pulse (20 ps), single mode pump source. We have developed this mid IR supercontinuum source based on highly purified solid-core tellurite glass fibers that are waveguide engineered for dispersion-zero matching with Tm-doped pulsed fiber laser pumps. The conversion efficiency from 1922nm pump to mid IR (2μm-5μm) supercontinuum is greater than 30%, and approaching 60% for the full spectrum. We have achieved > 1.2W covering from 1μm to 5μm with 2W of pump. In particular, the wavelength region above 4μm has been difficult to cover with supercontinuum sources based on ZBLAN or chalcogenide fibers. In contrast to that, our nonlinear tellurite fibers have a wider transparency window free of unwanted absorption, and are highly suited for extending the long wavelength emission above 4μm. We achieve spectral power density at 4.1μm already exceeding 0.2mW/nm and with potential for higher by scaling of pump power.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loveday, D.L.; Craggs, C.
Box-Jenkins-based multivariate stochastic modeling is carried out using data recorded from a domestic heating system. The system comprises an air-source heat pump sited in the roof space of a house, solar assistance being provided by the conventional tile roof acting as a radiation absorber. Multivariate models are presented which illustrate the time-dependent relationships between three air temperatures - at external ambient, at entry to, and at exit from, the heat pump evaporator. Using a deterministic modeling approach, physical interpretations are placed on the results of the multivariate technique. It is concluded that the multivariate Box-Jenkins approach is a suitable techniquemore » for building thermal analysis. Application to multivariate Box-Jenkins approach is a suitable technique for building thermal analysis. Application to multivariate model-based control is discussed, with particular reference to building energy management systems. It is further concluded that stochastic modeling of data drawn from a short monitoring period offers a means of retrofitting an advanced model-based control system in existing buildings, which could be used to optimize energy savings. An approach to system simulation is suggested.« less
Marson, D C; Earnst, K S; Jamil, F; Bartolucci, A; Harrell, L E
2000-08-01
To investigate the consistency of physician judgments of treatment consent capacity (competency) for patients with Alzheimer's disease (AD) when specific legal standards (LS) for competency are used, and to identify the LS most clinically relevant to experienced physicians. Control and AD patient participants were videotaped being administered a measure of capacity to consent to medical treatment. Study physicians viewed videotapes of these assessments individually and made competency judgments for each participant under different LS followed by their own personal judgment of competency. A university medical center. Participants were 10 older controls and 21 patients with AD (10 with mild and 11 with moderate AD). Five physicians with experience assessing the competency of AD patients were recruited from the geriatric psychiatry, geriatric medicine, and neurology services of a university medical center. The 31 participants were videotaped performing on a measure of treatment consent capacity (Capacity to Consent to Treatment Instrument) (CCTI). The CCTI consists of two clinical vignettes (A-neoplasm and B-cardiac) that test competency under five LS. Vignette A and B assessments were videotaped separately for each participant (total videotapes for sample = 62). Each study physician viewed each videotaped vignette individually, made judgments under each of the LS (competent or incompetent), and then made his/her own personal competency judgment. Physicians were blinded to participant diagnosis. Within participant group, consistency of physician judgments was evaluated across LS and personal judgments using percentage agreement and kappa. Agreement between personal and LS judgments for the AD group was evaluated for each physician using logistic regression. As expected, physicians as a group generally demonstrated very high percentage agreement in their LS and personal competency judgments for the control group. For the AD group, mean percentage judgment agreement among physicians ranged from a high of 84% (LS1) (evidencing a treatment choice) to a low of 67% (LS3) (appreciating consequences of treatment choice). Mean percentage agreement for personal competency judgments was 76%. For the AD sample, kappa analyses for physicians as a group demonstrated significant agreement not attributable to chance for LS5 (understanding treatment situation/choices) (k = 0.57, P = .001), LS4 (providing rational reasons for treatment choice) (k = 0.39, P = .04), and also for personal judgments (k = 0.48, P = .009). Analysis of LS judgment agreement within physician indicated that physicians applied the LS as discrete standards. Within-physician and for the AD sample, personal competency judgments were associated significantly with judgments on LS5 (P = .001), LS4 (P = .004), and LS3 (P < .04). Experienced physicians demonstrated significant agreement assessing competency in AD patients when judgments were based upon specific legal standards. Personal competency judgments of physicians showed a substantially higher level of agreement than found in a previous study, where specific LS were not used. These results suggest that consistency of physician competency judgments can be enhanced if they are guided by knowledge of specific LS. Physicians' personal competency judgments were most closely associated with comprehension and reasoning LS, the most conservative and clinically appropriate standards for deciding competency.
NASA Astrophysics Data System (ADS)
Urban, Joachim
The Stratosphere-Troposphere Exchange And climate Monitor (STEAM) radiometer is designed to provide vertically and horizontally well resolved profiles of key species in the climate relevant upper troposphere and lower stratosphere (UT/LS) altitude region such as H2O, O3, CO, HCN, CH3CN, CH3Cl, N2O, HNO3, and temperature. The instrument is a multi-beam limb sounder employing 12GHz wide sub-harmonically pumped double sideband mixers targeting the 324-336GHz (lower sideband) and 343.25-355.25GHz (upper sideband) spectral bands with a local oscillator set at 339.625GHz. Whilst the instrument configuration had been optimized during the recent years to fit the ESA Earth Explorer 7 candidate mission PREMIER, the instrument payload is now being studied in a smaller configuration for a different satellite mission in collaboration with international partners. The presentation provides an overview of the STEAM project and its science objectives and focuses on a description of the measurement capabilities of the newly configured STEAM radiometer, in comparison to related projects and existing sensors such as Odin/SMR and Aura/MLS.
Hamaekers, A E W; Götz, T; Borg, P A J; Enk, D
2010-03-01
Needle cricothyrotomy and subsequent transtracheal jet ventilation (TTJV) is one of the last options to restore oxygenation while managing an airway emergency. However, in cases of complete upper airway obstruction, conventional TTJV is ineffective and dangerous. We transformed a small, industrial ejector into a simple, manual ventilator providing expiratory ventilation assistance (EVA). An ejector pump was modified to allow both insufflation of oxygen and jet-assisted expiration through an attached 75 mm long transtracheal catheter (TTC) with an inner diameter (ID) of 2 mm by alternately occluding and releasing the gas outlet of the ejector pump. In a lung simulator, the modified ejector pump was tested at different compliances and resistances. Inspiration and expiration times were measured and achievable minute volumes (MVs) were calculated to determine the effect of EVA. The modified ejector pump shortened the expiration time and an MV up to 6.6 litre min(-1) could be achieved through a 2 mm ID TTC in a simulated obstructed airway. The principle of ejector-based EVA seems promising and deserves further evaluation.
F"orster-type mechanism of the redox-driven proton pump
NASA Astrophysics Data System (ADS)
Mourokh, Lev; Smirnov, Anatoly; Nori, Franco
2007-03-01
We propose a model to describe an electronically-driven proton pump in the cytochrome c oxidase (CcO). We examine the situation when the electron transport between the two sites embedded into the inner membrane of the mitochondrion occurs in parallel with the proton transfer from the protonable site that is close to the negative (inner) side of the membrane to the other protonable site located nearby the positive (outer) surface of the membrane. In addition to the conventional electron and proton tunnelings between the sites, the Coulomb interaction between electrons and protons localized on the corresponding sites leads to so-called F"orster transfer, i.e. to the process when the simultaneous electron and proton tunnelings are accompanied by the resonant energy transfer between the electrons and protons. Our calculations based on reasonable parameters have demonstrated that the F"orster process facilitates the proton pump at physiological temperatures. We have examined the effects of an electron voltage build-up, external temperature, and molecular electrostatics driving the electron and proton energies to the resonant conditions, and have shown that these parameters can control the proton pump operation.
Upconversion fiber-optic confocal microscopy under near-infrared pumping.
Kim, Do-Hyun; Kang, Jin U; Ilev, Ilko K
2008-03-01
We present a simple upconversion fiber-optic confocal microscope design using a near-infrared laser for pumping of a rare-earth-doped glass powder. The nonlinear optical frequency conversion process is highly efficient with more than 2% upconversion fluorescence efficiency at a near-infrared pumping wavelength of 1.55 microm. The upconversion confocal design allows the use of conventional Si detectors and 1.55 microm near-infrared pump light. The lateral and axial resolutions of the system were equal to or better than 1.10 and 13.11 microm, respectively.
Tang, Shi-Yang; Khoshmanesh, Khashayar; Sivan, Vijay; Petersen, Phred; O’Mullane, Anthony P.; Abbott, Derek; Mitchell, Arnan; Kalantar-zadeh, Kourosh
2014-01-01
Small-scale pumps will be the heartbeat of many future micro/nanoscale platforms. However, the integration of small-scale pumps is presently hampered by limited flow rate with respect to the input power, and their rather complicated fabrication processes. These issues arise as many conventional pumping effects require intricate moving elements. Here, we demonstrate a system that we call the liquid metal enabled pump, for driving a range of liquids without mechanical moving parts, upon the application of modest electric field. This pump incorporates a droplet of liquid metal, which induces liquid flow at high flow rates, yet with exceptionally low power consumption by electrowetting/deelectrowetting at the metal surface. We present theory explaining this pumping mechanism and show that the operation is fundamentally different from other existing pumps. The presented liquid metal enabled pump is both efficient and simple, and thus has the potential to fundamentally advance the field of microfluidics. PMID:24550485
Legionella saoudiensis sp. nov., isolated from a sewage water sample.
Bajrai, Leena Hussein; Azhar, Esam Ibraheem; Yasir, Muhammad; Jardot, Priscilla; Barrassi, Lina; Raoult, Didier; La Scola, Bernard; Pagnier, Isabelle
2016-11-01
A Gram-stain-negative, bacilli-shaped bacterial strain, LS-1T, was isolated from a sewage water sample collected in Jeddah, Saudi Arabia. The taxonomic position of strain LS-1T was investigated using a polyphasic taxonomic approach. Phylogenetic analysis based on 16S rRNA gene sequences and those of four other genes indicated that strain LS-1T belongs to the genus Legionella in the family Legionellaceae. Regarding the 16S rRNA gene, the most closely related species are Legionella rowbothamii LLAP-6T (98.6 %) and Legionella lytica L2T (98.5 %). The mip gene sequence of strain LS-1T showed 94 % sequence similarity with that of L. lytica L2T and 93 % similarity with that of L. rowbothamii LLAP-6T. Strain LS-1T grew optimally at a temperature of 32 °C on a buffered charcoal yeast extract (BCYE) agar plate in a 5 % CO2 atmosphere and had a flagellum. The combined phylogenetic, phenotypic and genomic sequence data suggest that strain LS-1T represents a novel species of the genus Legionella, for which the name Legionella saoudiensis sp. nov. is proposed. The type strain is LS-1T (=DSM 101682T=CSUR P2101T).
Mirmoghtadaee, Parisa; Heshmat, Ramin; Djalalinia, Shirin; Motamed-Gorji, Nazgol; Motlagh, Mohammad Esmaeil; Ardalan, Gelayol; Safiri, Saeid; Ahadi, Zeinab; Shafiee, Gita; Asayesh, Hamid; Qorbani, Mostafa; Yaghini, Omid; Kelishadi, Roya
2016-01-01
Background: Socioeconomic status (SES) is a major determinant of health inequality in children and adolescents. The aim of this study was to evaluate the association of SES of family and living region with self-rated health (SRH) and life satisfaction (LS) among children and adolescents. Methods: This study was a part of the fourth survey of a national surveillance program, which was conducted in 30 provinces of Iran in 2011-2012. LS and SRH were assessed by a questionnaire based on the World Health Organization-Global School-based student Health Survey (WHO-GSHS). Family SES was estimated using principal component analysis (PCA) and based on family assets, parental education and occupation, and type of school. Region SES was calculated using PCA and some variables including literacy rate, family assets and employment rate. Results: Out of 14,880 invited students, 13,486 (participation rate: 90.6%) completed the survey; of whom, 49.2% were girls, and 75.6% were from urban areas with the mean ± SD age of 12.47±3.36 years. In the multivariate model, SES of family and living region was associated with LS and good SRH. In the full models, in addition to all potential confounders, family and living region SES were included simultaneously. However, only the association of family SES with LS, and good SRH remained statistically significant. Conclusion: The effect of families' SES on SRH and LS is more important than regional SES. The presented patterns of SRH and LS may be useful in developing better health policies and conducting complementary studies in this field.
Shimansky, Yury P; Kang, Tao; He, Jiping
2004-02-01
A computational model of a learning system (LS) is described that acquires knowledge and skill necessary for optimal control of a multisegmental limb dynamics (controlled object or CO), starting from "knowing" only the dimensionality of the object's state space. It is based on an optimal control problem setup different from that of reinforcement learning. The LS solves the optimal control problem online while practicing the manipulation of CO. The system's functional architecture comprises several adaptive components, each of which incorporates a number of mapping functions approximated based on artificial neural nets. Besides the internal model of the CO's dynamics and adaptive controller that computes the control law, the LS includes a new type of internal model, the minimal cost (IM(mc)) of moving the controlled object between a pair of states. That internal model appears critical for the LS's capacity to develop an optimal movement trajectory. The IM(mc) interacts with the adaptive controller in a cooperative manner. The controller provides an initial approximation of an optimal control action, which is further optimized in real time based on the IM(mc). The IM(mc) in turn provides information for updating the controller. The LS's performance was tested on the task of center-out reaching to eight randomly selected targets with a 2DOF limb model. The LS reached an optimal level of performance in a few tens of trials. It also quickly adapted to movement perturbations produced by two different types of external force field. The results suggest that the proposed design of a self-optimized control system can serve as a basis for the modeling of motor learning that includes the formation and adaptive modification of the plan of a goal-directed movement.
Mirmoghtadaee, Parisa; Heshmat, Ramin; Djalalinia, Shirin; Motamed-Gorji, Nazgol; Motlagh, Mohammad Esmaeil; Ardalan, Gelayol; Safiri, Saeid; Ahadi, Zeinab; Shafiee, Gita; Asayesh, Hamid; Qorbani, Mostafa; Yaghini, Omid; Kelishadi, Roya
2016-01-01
Background: Socioeconomic status (SES) is a major determinant of health inequality in children and adolescents. The aim of this study was to evaluate the association of SES of family and living region with self-rated health (SRH) and life satisfaction (LS) among children and adolescents. Methods: This study was a part of the fourth survey of a national surveillance program, which was conducted in 30 provinces of Iran in 2011-2012. LS and SRH were assessed by a questionnaire based on the World Health Organization-Global School-based student Health Survey (WHO-GSHS). Family SES was estimated using principal component analysis (PCA) and based on family assets, parental education and occupation, and type of school. Region SES was calculated using PCA and some variables including literacy rate, family assets and employment rate. Results: Out of 14,880 invited students, 13,486 (participation rate: 90.6%) completed the survey; of whom, 49.2% were girls, and 75.6% were from urban areas with the mean ± SD age of 12.47±3.36 years. In the multivariate model, SES of family and living region was associated with LS and good SRH. In the full models, in addition to all potential confounders, family and living region SES were included simultaneously. However, only the association of family SES with LS, and good SRH remained statistically significant. Conclusion: The effect of families’ SES on SRH and LS is more important than regional SES. The presented patterns of SRH and LS may be useful in developing better health policies and conducting complementary studies in this field. PMID:28210588
Floreani, Annarosa; Cazzagon, Nora; Boemo, Deris Gianni; Baldovin, Tatjana; Baldo, Vincenzo; Egoue, Joel; Antoniazzi, Sara; Minola, Eliseo
2011-11-01
Patients with chronic hepatitis C and persistently normal alanine transaminase levels have recently been included in the guidelines for antiviral treatment. To evaluate the efficacy of PEG-interferon α-2a and weight-based ribavirin doses in patients with these characteristics in a single Italian centre. Patients with chronic hepatitis C and at least three normal alanine transaminase values over a 12-month period were offered a treatment with PEG-interferon α-2a 180 mg/week and ribavirin (800 mg/day for weight <60 kg; 1000 mg/day for weight >60 and <75 kg; 1200 mg/day for weight >75 kg) for 24 weeks (according to genotype 2 or 3) or for 48 weeks (according to genotype 1 or 4). Each patient at baseline underwent liver stiffness (LS) examination using Fibroscan. Data were analysed according to the intention-to-treat criteria. A total of 227 patients (55 men, 172 women) were enrolled into the study: 65 (28.6%) had genotype 1, 144 (63.4%) genotype 2, nine (4.0%) genotype 3 and nine (4.0%) genotype 4. Patients with genotype 2 or 3 (N=153 with easy genotypes) were allocated in group 1 and those with genotype 1 or 4 (N=74 with difficult genotypes) in group 2. According to the LS measurement, patients were classified as follows: 159 (70.0%) presented absent or mild fibrosis (LS=2.5-7.0 kPa), 61 (26.9%) patients had significant fibrosis (LS=7.1-9.5) and seven (3.1%) patients had severe fibrosis (LS >9.6). Twelve patients (5.3%) dropped out within 4 months because of side-effects, whereas 215 patients completed the study. Overall, 13 patients were considered nonresponders (5.7%) and six patients (2.6%) were relapsers to the therapy. The sustained virological response (SVR) rate was 85.4% and it was higher in 'easy' genotypes (2 or 3) compared with 'difficult' genotypes (1 or 4) (92.2 vs. 74.3%, P<0.001). No statistical difference was found in the SVR rate between patients presenting absent or mild fibrosis as against those with significant fibrosis. Multivariate analysis, including factors correlated with SVR, showed that easy genotype and female sex are significantly associated with a SVR. Patients with chronic hepatitis C and persistently normal transaminases have an 85.4% chance to clear the virus with conventional antiviral treatment. Female patients in fertile age with easy genotypes have a 100% chance to reach a SVR.
Yoshimura, Noriko
2014-05-01
To clarify the prevalence and estimate the number of people with osteoarthritis, and osteoporosis in Japan, we established a large-scale population-based cohort study entitled Research on Osteoarthritis/osteoporosis Against Disability (ROAD). The prevalence of lumbar spondylosis (LS) in men and women was 80.6% and 61.5%, respectively with utilizing the ROAD baseline data. The cumulative incidence of LS in men and women was 15.2%/y and 10.4%/y, respectively with using the follow-up data. The estimated number of prevalent cases and incident cases/y of LS in Japan was approximately 38 million and 9 million, respectively. Older age, male-sex, and greater BMI were associated with the occurrence of LS.
Chen, Sheng-Hung; Lai, Hsueh-Chou; Chiang, I-Ping; Su, Wen-Pang; Lin, Chia-Hsin; Kao, Jung-Ta; Chuang, Po-Heng; Hsu, Wei-Fan; Wang, Hung-Wei; Chen, Hung-Yao; Huang, Guan-Tarn; Peng, Cheng-Yuan
2018-01-01
To compare on-treatment and off-treatment parameters acquired using acoustic radiation force impulse elastography, the Fibrosis-4 (FIB-4) index, and aspartate aminotransferase-to-platelet ratio index (APRI) in patients with chronic hepatitis C (CHC). Patients received therapies based on pegylated interferon or direct-acting antiviral agents. The changes in paired patient parameters, including liver stiffness (LS) values, the FIB-4 index, and APRI, from baseline to sustained virologic response (SVR) visit (24 weeks after the end of treatment) were compared. Multiple regression models were used to identify significant factors that explained the correlations with LS, FIB-4, and APRI values and SVR. A total of 256 patients were included, of which 219 (85.5%) achieved SVR. The paired LS values declined significantly from baseline to SVR visit in all groups and subgroups except the nonresponder subgroup (n = 10). Body mass index (P = 0.0062) and baseline LS (P < 0.0001) were identified as independent factors that explained the LS declines. Likewise, the baseline FIB-4 (P < 0.0001) and APRI (P < 0.0001) values independently explained the declines in the FIB-4 index and APRI, respectively. Moreover, interleukin-28B polymorphisms, baseline LS, and rapid virologic response were identified as independent correlates with SVR. Paired LS measurements in patients treated for CHC exhibited significant declines comparable to those in FIB-4 and APRI values. These declines may have correlated with the resolution of necroinflammation. Baseline LS values predicted SVR.
A Proposed In Vitro Method to Assess Effects of Inhaled Particles on Lung Surfactant Function.
Sørli, Jorid B; Da Silva, Emilie; Bäckman, Per; Levin, Marcus; Thomsen, Birthe L; Koponen, Ismo K; Larsen, Søren T
2016-03-01
The lung surfactant (LS) lining is a thin liquid film covering the air-liquid interface of the respiratory tract. LS reduces surface tension, enabling lung surface expansion and contraction with minimal work during respiration. Disruption of surface tension is believed to play a key role in severe lung conditions. Inhalation of aerosols that interfere with the LS may induce a toxic response and, as a part of the safety assessment of chemicals and inhaled medicines, it may be relevant to study their impact on LS function. Here, we present a novel in vitro method, based on the constrained drop surfactometer, to study LS functionality after aerosol exposure. The applicability of the method was investigated using three inhaled asthma medicines, micronized lactose, a pharmaceutical excipient used in inhaled medication, and micronized albumin, a known inhibitor of surfactant function. The surfactometer was modified to allow particles mixed in air to flow through the chamber holding the surfactant drop. The deposited dose was measured with a custom-built quartz crystal microbalance. The alterations allowed the study of continuously increasing quantified doses of particles, allowing determination of the dose of particles that affects the LS function. The tested pharmaceuticals did not inhibit the function of a model LS even at extreme doses--neither did lactose. Micronized albumin, however, impaired surfactant function. The method can discriminate between safe inhaled aerosols--as exemplified by the approved inhaled medicines and the pharmaceutical excipient lactose--and albumin known to impair lung functionality by inhibiting LS function.
NASA Astrophysics Data System (ADS)
Shao, Yongni; Xie, Chuanqi; Jiang, Linjun; Shi, Jiahui; Zhu, Jiajin; He, Yong
2015-04-01
Visible/near infrared spectroscopy (Vis/NIR) based on sensitive wavelengths (SWs) and chemometrics was proposed to discriminate different tomatoes bred by spaceflight mutagenesis from their leafs or fruits (green or mature). The tomato breeds were mutant M1, M2 and their parent. Partial least squares (PLS) analysis and least squares-support vector machine (LS-SVM) were implemented for calibration models. PLS analysis was implemented for calibration models with different wavebands including the visible region (400-700 nm) and the near infrared region (700-1000 nm). The best PLS models were achieved in the visible region for the leaf and green fruit samples and in the near infrared region for the mature fruit samples. Furthermore, different latent variables (4-8 LVs for leafs, 5-9 LVs for green fruits, and 4-9 LVs for mature fruits) were used as inputs of LS-SVM to develop the LV-LS-SVM models with the grid search technique and radial basis function (RBF) kernel. The optimal LV-LS-SVM models were achieved with six LVs for the leaf samples, seven LVs for green fruits, and six LVs for mature fruits, respectively, and they outperformed the PLS models. Moreover, independent component analysis (ICA) was executed to select several SWs based on loading weights. The optimal LS-SVM model was achieved with SWs of 550-560 nm, 562-574 nm, 670-680 nm and 705-715 nm for the leaf samples; 548-556 nm, 559-564 nm, 678-685 nm and 962-974 nm for the green fruit samples; and 712-718 nm, 720-729 nm, 968-978 nm and 820-830 nm for the mature fruit samples. All of them had better performance than PLS and LV-LS-SVM, with the parameters of correlation coefficient (rp), root mean square error of prediction (RMSEP) and bias of 0.9792, 0.2632 and 0.0901 based on leaf discrimination, 0.9837, 0.2783 and 0.1758 based on green fruit discrimination, 0.9804, 0.2215 and -0.0035 based on mature fruit discrimination, respectively. The overall results indicated that ICA was an effective way for the selection of SWs, and the Vis/NIR combined with LS-SVM models had the capability to predict the different breeds (mutant M1, mutant M2 and their parent) of tomatoes from leafs and fruits.
Hovorka, Roman; Nodale, Marianna; Haidar, Ahmad; Wilinska, Malgorzata E
2013-01-01
We investigated whether continuous glucose monitoring (CGM) levels can accurately assess glycemic control while directing closed-loop insulin delivery. Data were analyzed retrospectively from 33 subjects with type 1 diabetes who underwent closed-loop and conventional pump therapy on two separate nights. Glycemic control was evaluated by reference plasma glucose and contrasted against three methods based on Navigator (Abbott Diabetes Care, Alameda, CA) CGM levels. Glucose mean and variability were estimated by unmodified CGM levels with acceptable clinical accuracy. Time when glucose was in target range was overestimated by CGM during closed-loop nights (CGM vs. plasma glucose median [interquartile range], 86% [65-97%] vs. 75% [59-91%]; P=0.04) but not during conventional pump therapy (57% [32-72%] vs. 51% [29-68%]; P=0.82) providing comparable treatment effect (mean [SD], 28% [29%] vs. 23% [21%]; P=0.11). Using the CGM measurement error of 15% derived from plasma glucose-CGM pairs (n=4,254), stochastic interpretation of CGM gave unbiased estimate of time in target during both closed-loop (79% [62-86%] vs. 75% [59-91%]; P=0.24) and conventional pump therapy (54% [33-66%] vs. 51% [29-68%]; P=0.44). Treatment effect (23% [24%] vs. 23% [21%]; P=0.96) and time below target were accurately estimated by stochastic CGM. Recalibrating CGM using reference plasma glucose values taken at the start and end of overnight closed-loop was not superior to stochastic CGM. CGM is acceptable to estimate glucose mean and variability, but without adjustment it may overestimate benefit of closed-loop. Stochastic CGM provided unbiased estimate of time when glucose is in target and below target and may be acceptable for assessment of closed-loop in the outpatient setting.
Design and Development of a Residential Gas-Fired Heat Pump
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vineyard, Edward Allan; Abu-Heiba, Ahmad; Mahderekal, Dr. Isaac
2017-01-01
Heating, ventilating, and air-conditioning equipment consumes 43% of the total primary energy consumption in U.S. households. Presently, conventional gas furnaces have maximum heating efficiencies of 98%. Electric air conditioners used in association with the furnace for cooling have a minimum seasonal energy efficiency ratio (SEER) of 14.0. A residential gas-fired heat pump (RGHP) was developed and tested under standard rating conditions, resulting in a significant increase in heating efficiency of over 40% versus conventional natural gas furnaces. The associated efficiency of the RGHP in cooling mode is comparable in efficiency to an electric air conditioner (14.0 SEER) when compared onmore » a primary energy basis. The RGHP is similar in nature to a conventional heat pump but with two main differences. First, the primary energy savings are higher, based on a site versus source comparison, as the result of using natural gas to supply shaft power to the compressor rather than an electric motor. Second, waste heat is recovered from the engine to supplement space heating and reduce the energy input. It can also be used to provide supplemental water heating. The system utilizes a programmable logic controller that allows variable-speed operation to achieve improved control to meet building loads. RGHPs significantly reduce peak electric use during periods of high demand, especially peak summer loads, as well as peak winter loads in regions with widespread use of electric heating. This contributes to leveling year-round gas loads, with the potential to increase annual gas demand in some regions. The widespread adoption of RGHPs will contribute to significant reductions in primary energy consumption and carbon emissions through improved efficiencies.« less
Zhan, Xiaobin; Jiang, Shulan; Yang, Yili; Liang, Jian; Shi, Tielin; Li, Xiwen
2015-09-18
This paper proposes an ultrasonic measurement system based on least squares support vector machines (LS-SVM) for inline measurement of particle concentrations in multicomponent suspensions. Firstly, the ultrasonic signals are analyzed and processed, and the optimal feature subset that contributes to the best model performance is selected based on the importance of features. Secondly, the LS-SVM model is tuned, trained and tested with different feature subsets to obtain the optimal model. In addition, a comparison is made between the partial least square (PLS) model and the LS-SVM model. Finally, the optimal LS-SVM model with the optimal feature subset is applied to inline measurement of particle concentrations in the mixing process. The results show that the proposed method is reliable and accurate for inline measuring the particle concentrations in multicomponent suspensions and the measurement accuracy is sufficiently high for industrial application. Furthermore, the proposed method is applicable to the modeling of the nonlinear system dynamically and provides a feasible way to monitor industrial processes.
Lima, Marcelo B; Barreto, Inakã S; Andrade, Stéfani Iury E; Almeida, Luciano F; Araújo, Mário C U
2012-10-15
In this study, a micro-flow-batch analyzer (μFBA) with solenoid micro-pumps for the photometric determination of iodate in table salt is described. The method is based on the reaction of iodate with iodide to form molecular iodine followed by the reaction with N,N-diethyl-p-phenylenediamine (DPD). The analytical signal was measured at 520 nm using a green LED integrated into the μFBA built in the urethane-acrylate resin. The analytical curve for iodate was linear in the range of 0.01-10.0 mg L(-1) with a correlation coefficient of 0.997. The limit of detection and relative standard deviation were estimated at 0.004 mg L(-1) and<1.5% (n=3), respectively. The accuracy was assessed through recovery test (97.6-103.5%) and independent analysis by a conventional titrimetric method. Comparing this technique with the conventional method, no statistically significant differences were observed when applying the paired t-test at a 95% confidence level. The proposed microsystem using solenoid micro-pumps presented satisfactory robustness and high sampling rate (170 h(-1)), with a low reagents consumption and a low cost to build the device. The proposed microsystem is a new alternative for automatic determination of iodate in table salt, comparing satisfactory to the recently flow system. Copyright © 2012 Elsevier B.V. All rights reserved.
Heshmat, Ramin; Qorbani, Mostafa; Safiri, Saeid; Eslami-Shahr Babaki, Amir; Matin, Nassim; Motamed-Gorji, Nazgol; Motlagh, Mohammad-Esmaeil; Djalalinia, Shirin; Ardalan, Gelayol; Mansourian, Morteza; Asayesh, Hamid; Kelishadi, Roya
2017-02-14
To assess the joint association of passive and active smoking with self-rated health and life satisfaction among Iranian children and adolescents. Using a multistage random cluster sampling method, a representative sample of 14 880 school students were selected from urban and rural areas of 30 provinces of Iran. Data were gathered using a questionnaire, a weight scale and metre. Participants were classified into four groups based on their smoking patterns: 'non-smoker', 'only active smoker', 'only passive smoker' and 'active and passive smoker'. Life satisfaction (LS) and self-rated health (SRH) were assessed by self-administered validated questionnaires based on the WHO-Global School-based student Health Survey (WHO-GSHS). Data were analysed using a t-test, χ 2 test and multiple logistic regression. A total of 13 486 individuals (6640 girls and 6846 boys) out of 14 880 invited participated in the study (response rate 90.6%). LS and good SRH showed linearly negative associations with smoking status in both sexes. The proportions of LS and SRH categories were significantly different among all subsets of smoking status. Those classified as 'non-smokers' had the highest proportions of LS and good SRH, followed by 'only passive smokers' and 'only active smokers', while those with 'active and passive smoking' had the lowest proportions of LS and good SRH. In a multivariate model, students in the 'active and passive smoking' group had lower odds of LS (OR 0.43; 95% CI 0.32 to 0.57) and good SRH (OR 0.51; 95% CI 0.38 to 0.68) than those in the 'non-smoker' group. Students in the 'only passive smoker' group also had lower odds of LS (OR 0.75; 95% CI 0.67 to 0.83) and good SRH (OR 0.72; 95% CI 0.66 to 0.80) compared with the 'non-smoker' group. Adolescents with different smoking habits and exposure patterns have poorer SRH and LS than non-smokers. Both active and passive smoking status could affect LS and SRH in adolescents. Therefore, smoking prevention strategies should be considered as a health priority in school health services for promoting psychological well-being in children and adolescents. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
A durable, non power consumptive, simple seal for rotary blood pumps.
Mitamura, Y; Sekine, K; Asakawa, M; Yozu, R; Kawada, S; Okamoto, E
2001-01-01
One of the key technologic requirements for rotary blood pumps is the sealing of the motor shaft. A mechanical seal, a journal bearing, magnetic coupling, and magnetic suspension have been developed, but they have drawbacks such as wear, thrombus formation, and power consumption. A magnetic fluid seal was developed for an axial flow pump. A magnetic fluid seal is durable, simple, and non power consumptive. Long-term experiments and finite element modeling (FEM) analyses confirmed these advantages. The seal body was composed of a Ned-Fe magnet and two pole pieces; the seal was formed by injecting ferrofluid into the gap (50 microm) between the pole pieces and the motor shaft. To contain the ferrofluid in the seal and to minimize the possibility of ferrofluid making contact with blood, a shield with a small cavity was attached to the pole piece. While submerged in blood, the sealing pressure of the seal was measured and found to be 188 mm Hg with ferrofluid LS-40 (saturated magnetization, 24.3 kA/m) at a motor speed of 10,000 rpm and 225 mm Hg under static conditions. The magnetic fluid seals performed perfectly at a pressure of 100 mm Hg for 594 + days in a static condition, and 51, 39+, and 34+ days at a motor speed of 8,000 rpm. FEM analyses indicated a theoretical sealing pressure of 260 mm Hg. The state of the magnetic fluid in the seal in water was observed with a microscope. Neither splashing of magnetic fluid nor mixing of the magnetic fluid and water was observed. The specially designed magnetic fluid seal for keeping liquids out is useful for axial flow blood pumps. The magnetic fluid seal was incorporated into an intracardiac axial flow pump.
Dwivedi, Gaurav Raj; Tiwari, Nimisha; Singh, Aastha; Kumar, Akhil; Roy, Sudeep; Negi, Arvind Singh; Pal, Anirban; Chanda, Debabrata; Sharma, Ashok; Darokar, Mahendra P
2016-03-01
The purpose of the present study was to study the synergy potential of gallic acid-based derivatives in combination with conventional antibiotics using multidrug resistant cultures of Escherichia coli. Gallic acid-based derivatives significantly reduced the MIC of tetracycline against multidrug resistant clinical isolate of E. coli. The best representative, 3-(3',4,'5'-trimethoxyphenyl)-4,5,6-trimethoxyindanone-1, an indanone derivative of gallic acid, was observed to inhibit ethidium bromide efflux and ATPase which was also supported by in silico docking. This derivative extended the post-antibiotic effect and decreased the mutation prevention concentration of tetracycline. This derivative in combination with TET was able to reduce the concentration of TNFα up to 18-fold in Swiss albino mice. This derivative was nontoxic and well tolerated up to 300 mg/kg dose in subacute oral toxicity study in mice. This is the first report of gallic acid-based indanone derivative as drug resistance reversal agent acting through ATP-dependent efflux pump inhibition.
Dhakar, Lokesh; Gudla, Sudeep; Shan, Xuechuan; Wang, Zhiping; Tay, Francis Eng Hock; Heng, Chun-Huat; Lee, Chengkuo
2016-01-01
Triboelectric nanogenerators (TENGs) have emerged as a potential solution for mechanical energy harvesting over conventional mechanisms such as piezoelectric and electromagnetic, due to easy fabrication, high efficiency and wider choice of materials. Traditional fabrication techniques used to realize TENGs involve plasma etching, soft lithography and nanoparticle deposition for higher performance. But lack of truly scalable fabrication processes still remains a critical challenge and bottleneck in the path of bringing TENGs to commercial production. In this paper, we demonstrate fabrication of large scale triboelectric nanogenerator (LS-TENG) using roll-to-roll ultraviolet embossing to pattern polyethylene terephthalate sheets. These LS-TENGs can be used to harvest energy from human motion and vehicle motion from embedded devices in floors and roads, respectively. LS-TENG generated a power density of 62.5 mW m−2. Using roll-to-roll processing technique, we also demonstrate a large scale triboelectric pressure sensor array with pressure detection sensitivity of 1.33 V kPa−1. The large scale pressure sensor array has applications in self-powered motion tracking, posture monitoring and electronic skin applications. This work demonstrates scalable fabrication of TENGs and self-powered pressure sensor arrays, which will lead to extremely low cost and bring them closer to commercial production. PMID:26905285
Rao, Yuan J; Hassanzadeh, Comron; Fischer-Valuck, Benjamin; Chicoine, Michael R; Kim, Albert H; Perkins, Stephanie M; Huang, Jiayi
2017-03-01
To investigate the patterns of care and outcomes in patients with craniopharyngioma in the National Cancer Data Base (NCDB). This study included 697 patients (166 pediatric and 531 adult cases) treated for craniopharyngioma between 2004 and 2012 in the NCDB. Adjuvant radiotherapy (RT) was defined if within 6 months of surgery. Limited surgery (LS) was defined as biopsy or subtotal resection. Proportional-hazards models were used to evaluate associations between covariates and overall survival (OS). A time-dependent analysis of RT was performed to account for early deaths after surgery. Median follow-up was 46 months. Overall, 21% of patients received adjuvant RT. Of patients with known surgical extent (n = 195), 71% had LS. Utilization of adjuvant RT increased from 18% in 2004-2007 to 24% in 2008-2012. Patterns of care regarding adjuvant RT or LS were not significantly different between adult and pediatric patients. Tumor size, low comorbidity, and LS were associated with increased utilization of adjuvant RT. The 5-year OS among patients treated with LS, LS+RT, and gross total resection were 75, 85, and 82% (p = 0.02). On multivariate analysis of the 195 patients with known surgical extent, LS+RT was associated with improved OS compared to LS (HR 0.22, 95% CI 0.05-0.99, p = 0.04), but was not significant when early deaths (<2 months from surgery) were removed to adjust for immortal-time bias. Medical practice regarding surgical approach and adjuvant RT are similar for pediatric and adult craniopharyngiomas. Immortal-time bias may confound assessment of OS for adjuvant RT. Prospective studies comparing adjuvant RT versus observation after LS are warranted.
Lee, Sung Yeon; Cho, Nam H; Jung, Young Ok; Seo, Young Il; Kim, Hyun Ah
2017-01-01
The purpose of this study was to investigate the prevalence of and the relevant risk factors for lumbar spondylosis (LS) among middle-aged and elderly rural Korean residents and to explore the association between radiographic LS and lower back pain (LBP) in relation to age and gender. This community-based, cross-sectional study evaluated 1512 subjects with available radiograph. The prevalence of LBP was obtained using a questionnaire and disability resulting from LBP was measured using a validated Korean version of the Oswestry disability index (ODI). In lumbar spine radiographs, vertebral levels from L1/2 to L4/5 were evaluated for the presence of osteophytes and joint-space narrowing (JSN), and Kellgren-Lawrence (KL) grading was applied. Of 4261 subjects aged 40-79 years, data from 1512 subjects were included. The prevalence of radiographic LS indicated by grade ≥2 osteophytes and JSN were 53.9 and 15.8%, respectively. Seventy-three percent of subjects had KL grade ≥2 spondylosis and LBP was present in 36.5% of subjects. Although LS was more common among males, the prevalence of LBP was higher among females. Age, male gender and history of hand or knee arthritis were risk factors for LS. LS was significantly associated with LBP mostly among females over 60 years old and correlated with the ODI after adjusting for age and gender. Our study among rural Korean residents revealed a high prevalence of LS and LBP. The association between LS and LBP was observed mostly among females and LS was significantly correlated with the severity of back pain.
Genomic and transcriptomic heterogeneity of colorectal tumours arising in Lynch syndrome.
Binder, Hans; Hopp, Lydia; Schweiger, Michal R; Hoffmann, Steve; Jühling, Frank; Kerick, Martin; Timmermann, Bernd; Siebert, Susann; Grimm, Christina; Nersisyan, Lilit; Arakelyan, Arsen; Herberg, Maria; Buske, Peter; Loeffler-Wirth, Henry; Rosolowski, Maciej; Engel, Christoph; Przybilla, Jens; Peifer, Martin; Friedrichs, Nicolaus; Moeslein, Gabriela; Odenthal, Margarete; Hussong, Michelle; Peters, Sophia; Holzapfel, Stefanie; Nattermann, Jacob; Hueneburg, Robert; Schmiegel, Wolff; Royer-Pokora, Brigitte; Aretz, Stefan; Kloth, Michael; Kloor, Matthias; Buettner, Reinhard; Galle, Jörg; Loeffler, Markus
2017-10-01
Colorectal cancer (CRC) arising in Lynch syndrome (LS) comprises tumours with constitutional mutations in DNA mismatch repair genes. There is still a lack of whole-genome and transcriptome studies of LS-CRC to address questions about similarities and differences in mutation and gene expression characteristics between LS-CRC and sporadic CRC, about the molecular heterogeneity of LS-CRC, and about specific mechanisms of LS-CRC genesis linked to dysfunctional mismatch repair in LS colonic mucosa and the possible role of immune editing. Here, we provide a first molecular characterization of LS tumours and of matched tumour-distant reference colonic mucosa based on whole-genome DNA-sequencing and RNA-sequencing analyses. Our data support two subgroups of LS-CRCs, G1 and G2, whereby G1 tumours show a higher number of somatic mutations, a higher amount of microsatellite slippage, and a different mutation spectrum. The gene expression phenotypes support this difference. Reference mucosa of G1 shows a strong immune response associated with the expression of HLA and immune checkpoint genes and the invasion of CD4+ T cells. Such an immune response is not observed in LS tumours, G2 reference and normal (non-Lynch) mucosa, and sporadic CRC. We hypothesize that G1 tumours are edited for escape from a highly immunogenic microenvironment via loss of HLA presentation and T-cell exhaustion. In contrast, G2 tumours seem to develop in a less immunogenic microenvironment where tumour-promoting inflammation parallels tumourigenesis. Larger studies on non-neoplastic mucosa tissue of mutation carriers are required to better understand the early phases of emerging tumours. Copyright © 2017 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd. Copyright © 2017 Pathological Society of Great Britain and Ireland. Published by John Wiley & Sons, Ltd.
Quality professional development for secondary science teachers
NASA Astrophysics Data System (ADS)
Mchazlett, Dwight Henry, Jr.
This record of study (ROS) explores the perceptions of three high school biology teachers who implemented a form of the Japanese originated Lesson Study Professional Development (LS PD) model. Additionally, this ROS reports on the perceptions of the internal stakeholders with regard to the model's viability as a potential solution to a proposed problem of practice where there was a lack of quality professional development for secondary biology teachers. The audience of internal stakeholders includes district administrators, high school teachers, and science teachers from the elementary and middle school grade levels. Participants of this study collaboratively explored the problem of practice in the fall semester of 2015, then implemented the LS PD model in the spring semester. The participants completed three cycles of LS that focused on collaboratively designing research-based lessons, teaching the lessons with peer observations, revising and re-teaching the lessons with peer observations, and reflecting on the participants' growth experiences. Four research questions were addressed: (a) What are the perceptions of the participants in regard to their own professional growth as a result of participating in the LS initiative? (b) What improvements to the LS PD model might facilitate future implementation? and (c) What are the perceptions of the LS dissemination audience toward LS as a viable solution to a lack of quality PD for secondary biology teachers? Results of the study suggested that LS PD may be a viable solution to the proposed problem of practice where there is a lack of quality professional development for secondary biology teachers. Long-term implications posit that LS PD can be adapted and scaled up to benefit all content areas and grade levels.
A Modelica-based Model Library for Building Energy and Control Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wetter, Michael
2009-04-07
This paper describes an open-source library with component models for building energy and control systems that is based on Modelica, an equation-based objectoriented language that is well positioned to become the standard for modeling of dynamic systems in various industrial sectors. The library is currently developed to support computational science and engineering for innovative building energy and control systems. Early applications will include controls design and analysis, rapid prototyping to support innovation of new building systems and the use of models during operation for controls, fault detection and diagnostics. This paper discusses the motivation for selecting an equation-based object-oriented language.more » It presents the architecture of the library and explains how base models can be used to rapidly implement new models. To demonstrate the capability of analyzing novel energy and control systems, the paper closes with an example where we compare the dynamic performance of a conventional hydronic heating system with thermostatic radiator valves to an innovative heating system. In the new system, instead of a centralized circulation pump, each of the 18 radiators has a pump whose speed is controlled using a room temperature feedback loop, and the temperature of the boiler is controlled based on the speed of the radiator pump. All flows are computed by solving for the pressure distribution in the piping network, and the controls include continuous and discrete time controls.« less
High-power, fixed, and tunable wavelength, grating-free cascaded Raman fiber lasers
NASA Astrophysics Data System (ADS)
Balaswamy, V.; Arun, S.; Aparanji, Santosh; Choudhury, Vishal; Supradeepa, V. R.
2018-04-01
Cascaded Raman lasers enable high powers at various wavelength bands inaccessible with conventional rare-earth doped lasers. The input and output wavelengths of conventional implementations are fixed by the constituent fiber gratings necessary for cascaded Raman conversion. We demonstrate here, a simple architecture for high power, fixed and wavelength tunable, grating-free, cascaded Raman conversion between different wavelength bands. The architecture is based on the recently proposed distributed feedback Raman lasers. Here, we implement a module which converts the Ytterbium band to the eye-safe 1.5micron region. We demonstrate pump-limited output powers of over 30W in fixed and continuously wavelength tunable configurations.
Dual-pumped nondegenerate four-wave mixing in semiconductor laser with a built-in external cavity
NASA Astrophysics Data System (ADS)
Wu, Jian-Wei; Qiu, Qi; Hyub Won, Yong
2017-04-01
In this paper, a semiconductor laser system consisting of a conventional multimode Fabry-Pérot laser diode with a built-in external cavity is presented and demonstrated. More than two resonance modes, whose peak levels are significantly higher than other residual modes, are simultaneously supported and output by adjusting the bias current and operating temperature of the active region. Based on this device, dual-pumped nondegenerate four-wave mixing—in which two pump waves and a single signal wave are simultaneously fed into the laser, and the injection power and wavelength of the injected pump and signal waves are changed—is observed and discussed thoroughly. The results show that while the wavelengths of pump wave A and signal wave S are kept constant, the other pump wave B jumps from about 1535 nm to 1578 nm, generating conversion signals with changed wavelengths. The achieved conversion bandwidth between the primary signal and the converted signal waves is broadly tunable in the range of several terahertz frequencies. Both the conversion efficiency and optical signal-to-noise ratio of the newly generated conversion signals are adopted to evaluate the performance of the proposed four-wave mixing process, and are strongly dependent on the wavelength and power of the injected waves. Here, the attained maximum conversion efficiency and optical signal-to-noise ratio are close to -22 dB and 15 dB, respectively.
Testing of a heat pump clothes dryer. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
McFadden, D.; Dieckmann, J.; Mallory, D.
1995-05-01
The integration of a heat pump heat source into a clothes dryer has been investigated by several U.S. and foreign appliance developers and manufacturers but no commercial or residential heat pump clothes dryers are currently available in North America. The objectives of this effort were to: (1) Evaluate a heat pump dryer prototype relative to residential dryer performance tests. (2) Quantify the product limitations. (3) Suggest design changes that would reduce the impact of the limitations or that have a positive impact on the benefits. (4) Position the product relative to utility DSM/IRP opportunities (e.g., reduced connected load, or energymore » conservation). (5) Develop preliminary cost data The program evaluated the performance of a prototype closed-cycle heat pump clothes dryer designed and built by the Nyle Corporation. The prototype design goals were: (1) Drying times equivalent to a conventional electric clothes dryer. (2) 60% reduction in energy consumption. (3) Effective lint removal (to prevent coil fouling). (4) Cool-down mode performance similar to conventional dryer. (5) 20 lb load capacity. (6) Low temperature dry for reduced clothes wrinkle. Test results indicated that the closed-cycle heat pump met some of the above mentioned goals but it fell short with respect to energy savings and dry time. Performance improvement recommendations were developed for the closed-cycle dryer approach. In addition, the closed-cycle design potential was compared to an open-cycle heat pump dryer configuration.« less
Cytotoxic Activity of Salicylic Acid-Containing Drug Models with Ionic and Covalent Binding
2015-01-01
Three different types of drug delivery platforms based on imidazolium ionic liquids (ILs) were synthesized in high preparative yields, namely, the models involving (i) ionic binding of drug and IL; (ii) covalent binding of drug and IL; and (iii) dual binding using both ionic and covalent approaches. Seven ionic liquids containing salicylic acid (SA-ILs) in the cation or/and in the anion were prepared, and their cytotoxicity toward the human cell lines CaCo-2 (colorectal adenocarcinoma) and 3215 LS (normal fibroblasts) was evaluated. Cytotoxicity of SA-ILs was significantly higher than that of conventional imidazolium-based ILs and was comparable to the pure salicylic acid. It is important to note that the obtained SA-ILs dissolved in water more readily than salicylic acid, suggesting benefits of possible usage of traditional nonsoluble active pharmaceutical ingredients in an ionic liquid form. PMID:26617961
LS/2000--The Integrated Library System from OCLC.
ERIC Educational Resources Information Center
Olson, Susan
1984-01-01
Discusses design features of the Online Catalog of LS/2000, OCLC's enhanced version of Integrated Library System. This minicomputer-based system provides bibliographic file maintenance, circulation control, and online catalog searching. Examples of available displays--holdings, full MARC, work forms, keyword entry, index selection, brief citation,…
2014-08-12
deformation of the hull due to blast . An LS- Dyna model which included the ConWep function [6] was run, with a charge mass corresponding to a STANAG...different models and blast loadings are shown in Table 3. These responses are based on generic seat properties and assumed dummy position, which can be...Comparison between MADYMO and LS- Dyna models An LS- Dyna model with ConWep blast force applied to all segments of the hull floor and a MADYMO model with
Three Generations of FPGA DAQ Development for the ATLAS Pixel Detector
NASA Astrophysics Data System (ADS)
Mayer, Joseph A., II
The Large Hadron Collider (LHC) at the European Center for Nuclear Research (CERN) tracks a schedule of long physics runs, followed by periods of inactivity known as Long Shutdowns (LS). During these LS phases both the LHC, and the experiments around its ring, undergo maintenance and upgrades. For the LHC these upgrades improve their ability to create data for physicists; the more data the LHC can create the more opportunities there are for rare events to appear that physicists will be interested in. The experiments upgrade so they can record the data and ensure the event won't be missed. Currently the LHC is in Run 2 having completed the first LS of three. This thesis focuses on the development of Field-Programmable Gate Array (FPGA)-based readout systems that span across three major tasks of the ATLAS Pixel data acquisition (DAQ) system. The evolution of Pixel DAQ's Readout Driver (ROD) card is presented. Starting from improvements made to the new Insertable B-Layer (IBL) ROD design, which was part of the LS1 upgrade; to upgrading the old RODs from Run 1 to help them run more efficiently in Run 2. It also includes the research and development of FPGA based DAQs and integrated circuit emulators for the ITk upgrade which will occur during LS3 in 2025.
Malik, Maninder; Rangel-Barajas, Claudia; Mach, Robert H; Luedtke, Robert R
2016-09-01
Several receptor mediated pathways have been shown to modulate the murine head twitch response (HTR). However, the role of sigma receptors in the murine (±)-2,5-dimethoxy-4-iodoamphetamine (DOI)-induced HTR has not been previously investigated. We examined the ability of LS-1-137, a novel sigma-1 vs. sigma-2 receptor selective phenylacetamide, to modulate the DOI-induced HTR in DBA/2J mice. We also assessed the in vivo efficacy of reference sigma-1 receptor antagonists and agonists PRE-084 and PPCC. The effect of the sigma-2 receptor selective antagonist RHM-1-86 was also examined. Rotarod analysis was performed to monitor motor coordination after LS-1-137 administration. Radioligand binding techniques were used to determine the affinity of LS-1-137 at 5-HT2A and 5-HT2C receptors. LS-1-137 and the sigma-1 receptor antagonists haloperidol and BD 1047 were able to attenuate a DOI-induced HTR, indicating that LS-1-137 was acting in vivo as a sigma-1 receptor antagonist. LS-1-137 did not compromise rotarod performance within a dose range capable of attenuating the effects of DOI. Radioligand binding studies indicate that LS-1-137 exhibits low affinity binding at both 5-HT2A and 5-HT2C receptors. Based upon the results from these and our previous studies, LS-1-137 is a neuroprotective agent that attenuates the murine DOI-induced HTR independent of activity at 5-HT2 receptor subtypes, D2-like dopamine receptors, sigma-2 receptors and NMDA receptors. LS-1-137 appears to act as a sigma-1 receptor antagonist to inhibit the DOI-induced HTR. Therefore, the DOI-induced HTR can be used to assess the in vivo efficacy of sigma-1 receptor selective compounds. Copyright © 2016. Published by Elsevier Inc.
Wellskins and slug tests: where's the bias?
NASA Astrophysics Data System (ADS)
Rovey, C. W.; Niemann, W. L.
2001-03-01
Pumping tests in an outwash sand at the Camp Dodge Site give hydraulic conductivities ( K) approximately seven times greater than conventional slug tests in the same wells. To determine if this difference is caused by skin bias, we slug tested three sets of wells, each in a progressively greater stage of development. Results were analyzed with both the conventional Bouwer-Rice method and the deconvolution method, which quantifies the skin and eliminates its effects. In 12 undeveloped wells the average skin is +4.0, causing underestimation of conventional slug-test K (Bouwer-Rice method) by approximately a factor of 2 relative to the deconvolution method. In seven nominally developed wells the skin averages just +0.34, and the Bouwer-Rice method gives K within 10% of that calculated with the deconvolution method. The Bouwer-Rice K in this group is also within 5% of that measured by natural-gradient tracer tests at the same site. In 12 intensely developed wells the average skin is <-0.82, consistent with an average skin of -1.7 measured during single-well pumping tests. At this site the maximum possible skin bias is much smaller than the difference between slug and pumping-test Ks. Moreover, the difference in K persists even in intensely developed wells with negative skins. Therefore, positive wellskins do not cause the difference in K between pumping and slug tests at this site.
Zhang, Jiang; Wang, James Z; Yuan, Zhen; Sobel, Eric S; Jiang, Huabei
2011-01-01
This study presents a computer-aided classification method to distinguish osteoarthritis finger joints from healthy ones based on the functional images captured by x-ray guided diffuse optical tomography. Three imaging features, joint space width, optical absorption, and scattering coefficients, are employed to train a Least Squares Support Vector Machine (LS-SVM) classifier for osteoarthritis classification. The 10-fold validation results show that all osteoarthritis joints are clearly identified and all healthy joints are ruled out by the LS-SVM classifier. The best sensitivity, specificity, and overall accuracy of the classification by experienced technicians based on manual calculation of optical properties and visual examination of optical images are only 85%, 93%, and 90%, respectively. Therefore, our LS-SVM based computer-aided classification is a considerably improved method for osteoarthritis diagnosis.
Regional-scale calculation of the LS factor using parallel processing
NASA Astrophysics Data System (ADS)
Liu, Kai; Tang, Guoan; Jiang, Ling; Zhu, A.-Xing; Yang, Jianyi; Song, Xiaodong
2015-05-01
With the increase of data resolution and the increasing application of USLE over large areas, the existing serial implementation of algorithms for computing the LS factor is becoming a bottleneck. In this paper, a parallel processing model based on message passing interface (MPI) is presented for the calculation of the LS factor, so that massive datasets at a regional scale can be processed efficiently. The parallel model contains algorithms for calculating flow direction, flow accumulation, drainage network, slope, slope length and the LS factor. According to the existence of data dependence, the algorithms are divided into local algorithms and global algorithms. Parallel strategy are designed according to the algorithm characters including the decomposition method for maintaining the integrity of the results, optimized workflow for reducing the time taken for exporting the unnecessary intermediate data and a buffer-communication-computation strategy for improving the communication efficiency. Experiments on a multi-node system show that the proposed parallel model allows efficient calculation of the LS factor at a regional scale with a massive dataset.
The logistic score: a criterion for hypothermia after perinatal asphyxia?
Wayenberg, Jean-Louis
2010-05-01
To identify during the first hour of life the asphyxiated term neonates who further develop moderate or severe neonatal encephalopathy. In 75 asphyxiated term infants, we measured postnatal arterial base deficit (BD30), assigned an early neurological score (ENS) according to their level of consciousness, respiration pattern and neonatal reflexes at 30 min of life and calculated the logistic score (LS) = (0.33 x BD30) - ENS. The receiver operating characteristics (ROC) methodology was applied to analyze the ability of the LS to correctly classify patients into two groups: normal or mild encephalopathy (60 patients) versus moderate or severe encephalopathy (15 patients). The area under the ROC curve of the LS for moderate or severe encephalopathy (+/- standard error) was 94.4 +/- 3.6%. At the threshold value of 1.2, the LS provided 87.5% sensitivity and 73.7% positive predictive value (PPV). The PPV of LS reaches 100% for a value >3.2, but this threshold allowed only 53.3% sensitivity. The LS is predictive of the neonatal neurological evolution after birth asphyxia and may help to select the high risk patients who are potential candidates for hypothermia therapy.
DIRECT CURRENT ELECTROMAGNETIC PUMP
Barnes, A.H.
1957-11-01
An improved d-c electromagnetic pump is presented in which the poles, and consequently the magetic gap at the poles, are tapered to be wider at the upstream end. In addition, the cross section of the tube carryiQ the liquid metal is tapered so that the velocity of the pumped liquid increases in the downstream direction at a rate such that the counter-induced voltage in the liquid metal remains constant as it traverses the region between the poles. This configuration compensates for the distortion of the magnetic field caused by the induced voltage that would otherwise result in the lowering of the pumping capacity. This improved electromagnetic pump as practical application in the pumping of liquid metal coolants for nuclear reactors where conventional positive displacement pumps have proved unsatisfactory due to the high temperatures and the corrosive properties of the liquid metals involved.
Laser-diode pumped 40-W Yb:YAG ceramic laser.
Hao, Qiang; Li, Wenxue; Pan, Haifeng; Zhang, Xiaoyi; Jiang, Benxue; Pan, Yubai; Zeng, Heping
2009-09-28
We demonstrated a high-power continuous-wave (CW) polycrystalline Yb:YAG ceramic laser pumped by fiber-pigtailed laser diode at 968 nm with 400 mum fiber core. The Yb:YAG ceramic laser performance was compared for different Yb(3+) ion concentrations in the ceramics by using a conventional end-pump laser cavity consisting of two flat mirrors with output couplers of different transmissions. A CW laser output of 40 W average power with M(2) factor of 5.8 was obtained with 5 mol% Yb concentration under 120 W incident pump power. This is to the best of our knowledge the highest output power in end-pumped bulk Yb:YAG ceramic laser.
Pump-probe nonlinear phase dispersion spectroscopy.
Robles, Francisco E; Samineni, Prathyush; Wilson, Jesse W; Warren, Warren S
2013-04-22
Pump-probe microscopy is an imaging technique that delivers molecular contrast of pigmented samples. Here, we introduce pump-probe nonlinear phase dispersion spectroscopy (PP-NLDS), a method that leverages pump-probe microscopy and spectral-domain interferometry to ascertain information from dispersive and resonant nonlinear effects. PP-NLDS extends the information content to four dimensions (phase, amplitude, wavelength, and pump-probe time-delay) that yield unique insight into a wider range of nonlinear interactions compared to conventional methods. This results in the ability to provide highly specific molecular contrast of pigmented and non-pigmented samples. A theoretical framework is described, and experimental results and simulations illustrate the potential of this method. Implications for biomedical imaging are discussed.
Pump-probe nonlinear phase dispersion spectroscopy
Robles, Francisco E.; Samineni, Prathyush; Wilson, Jesse W.; Warren, Warren S.
2013-01-01
Pump-probe microscopy is an imaging technique that delivers molecular contrast of pigmented samples. Here, we introduce pump-probe nonlinear phase dispersion spectroscopy (PP-NLDS), a method that leverages pump-probe microscopy and spectral-domain interferometry to ascertain information from dispersive and resonant nonlinear effects. PP-NLDS extends the information content to four dimensions (phase, amplitude, wavelength, and pump-probe time-delay) that yield unique insight into a wider range of nonlinear interactions compared to conventional methods. This results in the ability to provide highly specific molecular contrast of pigmented and non-pigmented samples. A theoretical framework is described, and experimental results and simulations illustrate the potential of this method. Implications for biomedical imaging are discussed. PMID:23609646
Diode pumped alkali vapor fiber laser
Payne, Stephen A.; Beach, Raymond J.; Dawson, Jay W.; Krupke, William F.
2007-10-23
A method and apparatus is provided for producing near-diffraction-limited laser light, or amplifying near-diffraction-limited light, in diode pumped alkali vapor photonic-band-gap fiber lasers or amplifiers. Laser light is both substantially generated and propagated in an alkali gas instead of a solid, allowing the nonlinear and damage limitations of conventional solid core fibers to be circumvented. Alkali vapor is introduced into the center hole of a photonic-band-gap fiber, which can then be pumped with light from a pump laser and operated as an oscillator with a seed beam, or can be configured as an amplifier.
Diode pumped alkali vapor fiber laser
Payne, Stephen A [Castro Valley, CA; Beach, Raymond J [Livermore, CA; Dawson, Jay W [Livermore, CA; Krupke, William F [Pleasanton, CA
2006-07-26
A method and apparatus is provided for producing near-diffraction-limited laser light, or amplifying near-diffraction-limited light, in diode pumped alkali vapor photonic-band-gap fiber lasers or amplifiers. Laser light is both substantially generated and propagated in an alkali gas instead of a solid, allowing the nonlinear and damage limitations of conventional solid core fibers to be circumvented. Alkali vapor is introduced into the center hole of a photonic-band-gap fiber, which can then be pumped with light from a pump laser and operated as an oscillator with a seed beam, or can be configured as an amplifier.
14. (Credit CBF) The McNeil Street Pumping Station c1926, after ...
14. (Credit CBF) The McNeil Street Pumping Station c1926, after substantial enlargement, from the front of the new combination main high service-low service pumping room. On the left, located over the old clear water well, is a circular building which housed both the laboratory and the chlorination room (it was added c1911). The tank above the lab-chlorination room is the filter wash water tank (new). From: South-West Waterworks Association Convention, Shreveport, Louisiana, October 1926, Souvenir Booklet, p.19) - McNeil Street Pumping Station, McNeil Street & Cross Bayou, Shreveport, Caddo Parish, LA
Unstable Resonator Retrofitted Handheld Laser Designator
1978-06-01
retrofitted with a negative-branch unstable resona- tor laser and hybrid pump cavity in place of the conventional plane-mirror/ porro prism resonator and...directed by prism B to an expanding telescope, shared with the viewing system of the designator. The actual, unfolded resonator length is approxi...was performed based on using a plane- parallel cavity consisting of a 47% reflectivity output coupler, porro - prism reflector, and the same LiNb03
Hysteroscopic tubal sterilization: a health economic literature review.
2013-01-01
Hysteroscopic sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. In contrast to the laparoscopic technique, a hysteroscope is used to pass permanent microinserts through the cervix and place them in the fallopian tubes. This procedure does not require local or general anesthesia and can be performed in an office setting. The objective of this analysis was to determine, based on published literature, the cost-effectiveness of hysteroscopic tubal sterilization (HS) compared with laparoscopic tubal ligation (LS) for permanent female sterilization. A systematic literature search was conducted for studies published between January 1, 2008, and December 11, 2012. Potentially relevant studies were identified based on the title and abstract. Cost-utility analyses (studies that report outcomes in terms of costs and quality-adjusted life-years) were prioritized for inclusion. When not available, cost-effectiveness, cost-benefit, and cost-consequence analyses were considered. Costing studies were considered in the absence of all other analyses. A total of 33 abstracts were identified. Three cost analyses were included. A retrospective chart review from Canada found that HS was $111 less costly than LS; a prospective activity-based cost management study from Italy reported that it was €337 less costly than LS; and the results of an American decision model showed that HS was $1,178 less costly than LS. All studies had limited applicability to the Ontario health care system due to differences in setting, resource use, and costs. Three cost analyses found that, although the HS procedure was more expensive due to the cost of the microinserts, HS was less costly than LS overall due to the shorter recovery time required. Hysteroscopic sterilization is a minimally invasive alternative to conventional tubal ligation for women who want a permanent method of contraception. Both approaches involve closing off the fallopian tubes, preventing the egg from moving down the tube and the sperm from reaching the egg. Tubal ligation is a surgical procedure to tie or seal the fallopian tubes, and it usually requires general anesthesia. In contrast, hysteroscopic tubal sterilization can be performed in 10 minutes in an office setting without general or even local anesthesia. A tiny device called a microinsert is inserted into each fallopian tube through the vagina, cervix, and uterus without surgery. An instrument called a hysteroscope allows the doctor to see inside the body for the procedure. Once the microinserts are in place, scar tissue forms around them and blocks the fallopian tubes. Health Quality Ontario commissioned a systematic review of published economic literature to determine whether hysteroscopic sterilization is cost-effective compared to tubal ligation. This review did not find any studies that reported results in terms of both costs and effectiveness or costs and quality-adjusted life-years. We did find 3 costing studies and included them in our review. All of these studies found that when hysteroscopic sterilization was performed as an outpatient procedure, it was less expensive than tubal ligation due to a shorter recovery time. However, none of the studies apply directly to Ontario because of differences in our health care system compared to those in the studies.
Post-Irradiation Polymerization of a Silorane Composite
2013-04-26
methacrylate-based two- step self-etching adhesive system that is necessary to bond the silorane to tooth 3 structure. The dentin bond strength of...the Filtek LS system is equivalent to that of methacrylate-based systems if the Filtek LS primer and adhesive are used. However, siloranes are not...Maj Bryan Wilson 2. Academic Title: Resident, Advanced Education in General· Dentistry Residency (AEGD-2) 3. School/Department/Center: Air Force
DOE Office of Scientific and Technical Information (OSTI.GOV)
Savanier, Marc, E-mail: msavanier@eng.ucsd.edu; Kumar, Ranjeet; Mookherjea, Shayan, E-mail: smookherjea@eng.ucsd.edu
Silicon photonic microchips may be useful for compact, inexpensive, room-temperature optically pumped photon-pair sources, which unlike conventional photon-pair generators based on crystals or optical fibers, can be manufactured using CMOS-compatible processes on silicon wafers. It has been shown that photon pairs can be created in simple structures such as microring resonators at a rate of a few hundred kilohertz using less than a milliwatt of optical pump power, based on the process of spontaneous four-wave mixing. To create a practical photon-pair source, however, also requires some way of monitoring the device and aligning the pump wavelength when the temperature varies,more » since silicon resonators are highly sensitive to temperature. In fact, monitoring photodiodes are standard components in classical laser diodes, but the incorporation of germanium or InGaAs photodiodes would raise the cost and fabrication complexity. Here, we present a simple and effective all-electronic technique for finding the optimum operating point for the microring used to generate photon pairs, based on measuring the reverse-biased current in a silicon p-i-n junction diode fabricated across the waveguide that constitutes the silicon microring. We show that by monitoring the current, and using it to tune the pump laser wavelength, the photon-pair generation properties of the microring can be preserved over a temperature range of more than 30 °C.« less
Louw, Adriaan; Diener, Ina
2015-01-01
Background Recently a preoperative pain neuroscience education (NE) program was developed for lumbar surgery (LS) for radiculopathy as a means to decrease postoperative pain and disability. This study attempts to determine the short term effects, if any, of providing NE before surgery on patient outcomes. Methods A case series of 10 patients (female = 7) received preoperative one-on-one educational session by a physical therapist on the neuroscience of pain, accompanied by an evidence-based booklet, prior to LS for radiculopathy. Post-intervention data was gathered immediately after NE, as well as 1, 3 and 6 months following LS. Primary outcome measures were Pain Catastrophization Scale (PCS), forward flexion, straight leg raise (SLR) and beliefs regarding LS. Results Immediately following NE for LS for radiculopathy, all patients had lower PCS scores, with 5 patients exceeding the MDC score of 9.1 and 8 of the patients had PCS change scores exceeding the MDC by the 1, 3 and 6 month follow ups. Physical changes showed that fingertip-to-floor test in 6 patients had changes in beyond the MDC of 4.5 cm and 6 patients had changes in SLR beyond the MDC of 5.7°. The main finding, however, indicated a positive and more realistic shift in expectations regarding pain after the impending LS by all patients. Conclusions The results of the case series suggest that immediately after NE, patients scheduled for LS for radiculopathy had meaningful detectable changes in pain catastrophizing, fingertip-to-floor test, passive SLR and positive shifts in their beliefs about LS. PMID:26056626
A comparative analysis of pedometry in measuring physical activity of children.
Scruggs, Philip W
2007-10-01
The purpose of this study was to examine the step and physical activity time output features of the Walk4Life LS2505 pedometer under field physical activity conditions. Data were collected on 288 (12.62 +/- 1.23 yr) participants during a school-based structured physical activity program. Participants' physical activity levels were concurrently measured via the Yamax SW701 (Yamax Corp., Japan) and Walk4Life LS2505 (Walk4Life Inc., Plainfield, IL) pedometers, and System for Observing Fitness Instruction Time (SOFIT) physical activity coding mechanism. Relative and absolute agreement between SW701 (criterion) and LS2505 steps per minute, and SOFIT (criterion) and LS2505 physical activity time (min) were analyzed overall, and across physical activity content themes and physical activity quartiles. Physical activity measure correlations were moderately strong to strong (r = 0.85-0.98, P < 0.05); however, the LS2505 significantly underestimated steps per minute (M(diff) = 6.37 +/- 5.79, P < 0.05) and overestimated physical activity time (M(diff) = -7.73 +/- 3.13, P < 0.05). When LS2505 steps per minute were examined across physical activity themes and quartiles, clinically acceptable absolute error scores (
Involvement of lateral septum in alcohol's dopamine-elevating effect in the rat.
Jonsson, Susanne; Morud, Julia; Stomberg, Rosita; Ericson, Mia; Söderpalm, Bo
2017-01-01
Drugs of abuse share the ability to increase extracellular dopamine (DA) levels in the mesolimbic DA system. This effect has been linked to positive and reinforcing experiences of drug consumption and is presumed to be of importance for continued use, as well as for the development of dependence and addiction. Previous rat studies from our lab have implicated a neuronal circuitry involving glycine receptors in nucleus accumbens (nAc) and, secondarily, nicotinic acetylcholine receptors in the ventral tegmental area (VTA) in ethanol's (EtOH) DA-elevating effect. The work presented here, performed in male Wistar rats, suggests that the lateral septum (LS), which has previously been associated with different aspects of EtOH-related behaviour, is involved as well. In vivo microdialysis methodology demonstrated that blocking the generation of action potentials in LS using tetrodotoxin prevented a DA increase in nAc after accumbal EtOH perfusion. Retrograde tracing and polymerase chain reaction (PCR) were used to identify and characterize cells projecting to VTA from nAc/LS and from LS to nAc. Based on the PCR results, cells projecting from both LS/nAc to anterior VTA and from LS to nAc were mainly GABAergic neurons expressing glycine receptors, and these cells are presumed to be involved in mediating the DA-elevating effect of EtOH. These results provide further evidence implicating LS in the reinforcing effects of EtOH. Additional studies are needed to investigate LS involvement in EtOH consumption behaviour and its potential role in the development of dependence and addiction. © 2015 Society for the Study of Addiction.
Marikkar, Jalaldeen Mohammed Nazrim; Rana, Sohel
2014-01-01
A study was conducted to detect and quantify lard stearin (LS) content in canola oil (CaO) using differential scanning calorimetry (DSC). Authentic samples of CaO were obtained from a reliable supplier and the adulterant LS were obtained through a fractional crystallization procedure as reported previously. Pure CaO samples spiked with LS in levels ranging from 5 to 15% (w/w) were analyzed using DSC to obtain their cooling and heating profiles. The results showed that samples contaminated with LS at 5% (w/w) level can be detected using characteristic contaminant peaks appearing in the higher temperature regions (0 to 70°C) of the cooling and heating curves. Pearson correlation analysis of LS content against individual DSC parameters of the adulterant peak namely peak temperature, peak area, peak onset temperature indicated that there were strong correlations between these with the LS content of the CaO admixtures. When these three parameters were engaged as variables in the execution of the stepwise regression procedure, predictive models for determination of LS content in CaO were obtained. The predictive models obtained with single DSC parameter had relatively lower coefficient of determination (R(2) value) and higher standard error than the models obtained using two DSC parameters in combination. This study concluded that the predictive models obtained with peak area and peak onset temperature of the adulteration peak would be more accurate for prediction of LS content in CaO based on the highest coefficient of determination (R(2) value) and smallest standard error.
Robust Magnetotelluric Impedance Estimation
NASA Astrophysics Data System (ADS)
Sutarno, D.
2010-12-01
Robust magnetotelluric (MT) response function estimators are now in standard use by the induction community. Properly devised and applied, these have ability to reduce the influence of unusual data (outliers). The estimators always yield impedance estimates which are better than the conventional least square (LS) estimation because the `real' MT data almost never satisfy the statistical assumptions of Gaussian distribution and stationary upon which normal spectral analysis is based. This paper discuses the development and application of robust estimation procedures which can be classified as M-estimators to MT data. Starting with the description of the estimators, special attention is addressed to the recent development of a bounded-influence robust estimation, including utilization of the Hilbert Transform (HT) operation on causal MT impedance functions. The resulting robust performances are illustrated using synthetic as well as real MT data.
Analysis and Test of a Proton Exchange Membrane Fuel Cell Power System for Space Power Applications
NASA Technical Reports Server (NTRS)
Vasquez, Arturo; Varanauski, Donald; Clark, Robert, Jr.
2000-01-01
An effort is underway to develop a prototype Proton Exchange Membrane (PEM) Fuel Cell breadboard system for fuhlre space applications. This prototype will be used to develop a comprehensive design basis for a space-rated PEM fuel cell powerplant. The prototype system includes reactant pressure regulators, ejector-based reactant pumps, a 4-kW fuel cell stack and cooling system, and a passive, membranebased oxygen / water separator. A computer model is being developed concurrently to analytically predict fluid flow in the oxidant reactant system. Fuel cells have historically played an important role in human-rated spacecraft. The Gemini and Apollo spacecraft used fuel cells for vehicle electrical power. The Space Shuttle currently uses three Alkaline Fuel Cell Powerplants (AFCP) to generate all of the vehicle's 15-20kW electrical power. Engineers at the Johnson Space Center have leveraged off the development effort ongoing in the commercial arena to develop PEM fuel cel ls for terrestrial uses. The prototype design originated from efforts to develop a PEM fuel cell replacement for the current Space Shuttle AFCP' s. In order to improve on the life and an already excellent hi storical record of reliability and safety, three subsystems were focused on. These were the fuel cell stack itself, the reactant circulation devices, and reactant / product water separator. PEM fuel cell stack performance is already demonstrating the potential for greater than four times the useful life of the current Shuttle's AFCP. Reactant pumping for product water removal has historically been accomplished with mechanical pumps. Ejectors offer an effective means of reactant pumping as well as the potential for weight reduction, control simplification, and long life. Centrifugal water separation is used on the current AFCP. A passive, membrane-based water separator offers compatibility with the micro-gravity environment of space, and the potential for control simplification, elimination of moving parts in an oxygen environment, and long life. The prototype system has been assembled from components that have previously been tested and evaluated at the component level. Preliminary data obtained from tests performed with the prototype system, as well as other published data, has been used to validate the analytical component models. These components have been incorporated into an integrated oxidant fluid system model. Results obtained from both the performance tests and the analytical model are presented.
Liu, Xue-Mei; Zhang, Hai-Liang
2014-10-01
Ultraviolet/visible (UV/Vis) spectroscopy was studied for the rapid determination of chemical oxygen demand (COD), which was an indicator to measure the concentration of organic matter in aquaculture water. In order to reduce the influence of the absolute noises of the spectra, the extracted 135 absorbance spectra were preprocessed by Savitzky-Golay smoothing (SG), EMD, and wavelet transform (WT) methods. The preprocessed spectra were then used to select latent variables (LVs) by partial least squares (PLS) methods. Partial least squares (PLS) was used to build models with the full spectra, and back- propagation neural network (BPNN) and least square support vector machine (LS-SVM) were applied to build models with the selected LVs. The overall results showed that BPNN and LS-SVM models performed better than PLS models, and the LS-SVM models with LVs based on WT preprocessed spectra obtained the best results with the determination coefficient (r2) and RMSE being 0. 83 and 14. 78 mg · L(-1) for calibration set, and 0.82 and 14.82 mg · L(-1) for the prediction set respectively. The method showed the best performance in LS-SVM model. The results indicated that it was feasible to use UV/Vis with LVs which were obtained by PLS method, combined with LS-SVM calibration could be applied to the rapid and accurate determination of COD in aquaculture water. Moreover, this study laid the foundation for further implementation of online analysis of aquaculture water and rapid determination of other water quality parameters.
Rangel-Barajas, Claudia; Malik, Maninder; Taylor, Michelle; Neve, Kim A.; Mach, Robert H.; Luedtke, Robert R.
2014-01-01
LS-3-134 is a substituted N-phenylpiperazine derivative that has been reported to exhibit a) high-affinity binding (Ki value 0.2 nM) at human D3 dopamine receptors, b) >100-fold D3 vs. D2 dopamine receptor subtype binding selectivity and c) low-affinity binding (Ki values >5,000 nM) at sigma 1 and sigma 2 receptors. Based upon a forskolin-dependent activation of the adenylyl cyclase inhibition assay, LS-3-134 is a weak partial agonist at both D2 and D3 dopamine receptor subtypes (29% and 35% of full agonist activity, respectively). In this study, [3H]-labeled LS-3-134 was prepared and evaluated to further characterize its use as a D3 dopamine receptor selective radioligand. Kinetic and equilibrium radioligand binding studies were performed. This radioligand rapidly reaches equilibrium (10-15 min at 37°C) and binds with high affinity to both human (Kd = 0.06 ± 0.01 nM) and rat (Kd = 0.2 ± 0.02 nM) D3 receptors expressed in HEK-293 cells. Direct and competitive radioligand binding studies using rat caudate and nucleus accumbens tissue indicate that [3H]LS-3-134 selectively binds a homogeneous population of binding sites with a dopamine D3 receptor pharmacological profile. Based upon these studies we propose that [3H]LS-3-134 represents a novel D3 dopamine receptor selective radioligand that can be used for studying the expression and regulation of the D3 dopamine receptor subtype. PMID:25041389
Solid-state laser pumping with a planar compound parabolic concentrator.
Panteli, D V; Pani, B M; Beli, L Z
1997-10-20
A novel solid-state laser-pumping scheme is proposed that combines a reflective lamp chamber and a compound parabolic concentrator (CPC) as a light guide. The CPC is made of a transparent material of high refractive index, and light is guided by the total internal reflection, with drastically reduced reflection losses. Material is chosen so that the absorption losses are minimized in the pumping wavelength range. The lamp chamber is designed with the principles of nonimaging optics, which ensures that the radiation is efficiently transferred from the lamp to the input aperture of the CPC. The pumping efficiency was first estimated theoretically, which gave us enough justification for the more accurate calculations with ray tracing. Single as well as multiple pumping cavities are discussed. New pumping geometry results in significantly increased pumping efficiency compared with conventional geometries. Also the lamp and the laser rod are separated, leading to reduced thermal load. We found that the proposed pumping method is also applicable to diode-pumped lasers.
End-pumped Nd:YVO4 laser with reduced thermal lensing via the use of a ring-shaped pump beam.
Lin, Di; Andrew Clarkson, W
2017-08-01
A simple approach for alleviating thermal lensing in end-pumped solid-state lasers using a pump beam with a ring-shaped intensity distribution to decrease the radial temperature gradient is described. This scheme has been implemented in a diode-end-pumped Nd:YVO 4 laser yielding 14 W of TEM 00 output at 1.064 μm with a corresponding slope efficiency of 53% and a beam propagation factor (M 2 ) of 1.08 limited by available pump power. By comparison, the same laser design with a conventional quasi-top-hat pump beam profile of approximately equal radial extent yielded only 9 W of output before the power rolled over due to thermal lensing. Further investigation with the aid of a probe beam revealed that the thermal lens power was ∼30% smaller for the ring-shaped pump beam compared to the quasi-top-hat beam. The implications for further power scaling in end-pumped laser configurations are considered.
Lu, Yi-Chien; Lin, Ying Chin; Lin, Yen-Kuang; Liu, Yi-Jui; Chang, Kwang-Hwa; Chieng, Poon-Ung; Chan, Wing P.
2016-01-01
Diagnosis of osteoporosis is based on bone mineral density (BMD) measurement, which is site dependent and commonly discordant between measurement sites. We aimed to determine the prevalence of osteoporosis diagnosed based on BMD T-scores measured by dual-energy x-ray absorptiometry (DXA) at different sites: the lumbar spine (LS) alone, femoral neck (FN) alone, or both. A total of 1712 women and 2028 men with LS and FN BMD measurements were enrolled. Over 50% discordance was found between osteoporosis classifications based on T-scores measured at the LS and FN. Use of the lowest T-scores measured at both the LS and right and left FN (rather than one site) significantly increased the prevalence of osteoporosis from 4.03 to 10.75% in postmenopausal women and 1.82 to 4.29% in men aged ≧50 years (p < 0.001). The trends of overall and age-adjusted prevalence of osteoporosis were similar in women and men. Osteoporosis was diagnosed at a higher rate if the USA reference rather than the Asia reference was used to calculate the T-score (26.64% vs. 10.75%). In conclusion, diagnosis based on the lowest T-score from multiple site BMD measurement can increase the prevalence of osteoporosis, demonstrating the higher sensitivity of the multiple site measurement strategy. PMID:27143609
Smidt, D; Torpet, L A; Nauntofte, B; Heegaard, K M; Pedersen, A M L
2011-06-01
To investigate the associations between age, gender, systemic diseases, medications, labial and whole salivary flow rates and oral and ocular dryness in older people. Symptoms of oral and ocular dryness, systemic diseases, medications (coded according to the Anatomical therapeutic chemical (ATC) classification system), tobacco and alcohol consumption were registered, and unstimulated labial (LS) and unstimulated (UWS) and chewing-stimulated (SWS) whole salivary flow rates were measured in 668 randomly selected community-dwelling elderly aged 65-95. Presence of oral (12%) and ocular (11%) dryness was positively correlated. Oral dryness was associated with low UWS, SWS and LS, and ocular dryness with low UWS and SWS. Oral and ocular dryness was related to female gender, but not to age. Only four persons in the healthy and nonmedicated subgroups reported oral and ocular dryness. The numbers of diseases and medications were higher in the older age groups and associated with oral and ocular dryness, low UWS, SWS and LS. On average, women were slightly older, reported more oral and ocular dryness and had lower UWS, SWS, LS and higher numbers of diseases and medications. High prevalence and odds ratios for oral dryness were associated with metabolic, respiratory and neurological diseases and intake of thyroid hormones, respiratory agents (primarily glucocorticoids), psycholeptics and/or psychoanaleptics, antineoplastics, proton pump inhibitors, antidiabetics, loop diuretics, antispasmodics, quinine and bisphosphonates. Ocular dryness was especially associated with neurological diseases and intake of psycholeptics and/or psychoanaleptics. Intake of magnesium hydroxide, antithrombotics, cardiac agents, thiazides, beta-blockers, calcium channel blockers, ACE inhibitors/angiotensin II antagonists, statins, glucosamine, paracetamol/opioids, ophthalmologicals and certain combination therapies was related to oral and ocular dryness. In older people, oral and ocular dryness are associated with low salivary flow rates, specific as well as high number of diseases and medications, but neither with age and gender per se nor with tobacco and alcohol consumption. New detailed information concerning associations between medications and oral and ocular dryness has been obtained using the ATC classification system. © 2010 John Wiley & Sons A/S.
Ellis, Scott Michael; Varley, Martin; Howell, Stuart; Trochsler, Markus; Maddern, Guy; Hewett, Peter; Runge, Tina; Mees, Soeren Torge
2016-08-01
Training in laparoscopic surgery is important not only to acquire and improve skills but also avoid the loss of acquired abilities. The aim of this single-centre, prospective randomized study was to assess skill acquisition of different laparoscopic techniques and identify the point in time when acquired skills deteriorate and training is needed to maintain these skills. Sixty surgical novices underwent laparoscopic surgery (LS) and single-incision laparoscopic surgery (SILS) baseline training (BT) performing two validated tasks (peg transfer, precision cutting). The novices were randomized into three groups and skills retention testing (RT) followed after 8 (group A), 10 (group B) or 12 (group C) weeks accordingly. Task performance was measured in time with time penalties for insufficient task completion. 92 % of the participants completed the BT and managed to complete the task in the required time frame of proficiency. Univariate and multivariate analyses revealed that SILS (P < 0.0001) and precision cutting (P < 0.0001) were significantly more difficult. Males performed significantly better than females (P < 0.005). For LS, a deterioration of skills (comparison of BT vs RT) was not identified; however, for SILS a significant deterioration of skills (adjustment of BT and RT values) was demonstrated for all groups (A-C) (P < 0.05). Our data reveal that complex laparoscopic tasks (cutting) and techniques (SILS) are more difficult to learn and acquired skills more difficult to maintain. Acquired LS skills were maintained for the whole observation period of 12 weeks but SILS skills had begun to deteriorate at 8 weeks. These data show that maintenance of LS and SILS skills is divergent and training curricula need to take these specifics into account.
Liver reserve function assessment by acoustic radiation force impulse imaging
Sun, Xiao-Lan; Liang, Li-Wei; Cao, Hui; Men, Qiong; Hou, Ke-Zhu; Chen, Zhen; Zhao, Ya-E
2015-01-01
AIM: To evaluate the utility of liver reserve function by acoustic radiation force impulse (ARFI) imaging in patients with liver tumors. METHODS: Seventy-six patients with liver tumors were enrolled in this study. Serum biochemical indexes, such as aminotransferase (ALT), aspartate aminotransferase (AST), serum albumin (ALB), total bilirubin (T-Bil), and other indicators were observed. Liver stiffness (LS) was measured by ARFI imaging, measurements were repeated 10 times, and the average value of the results was taken as the final LS value. Indocyanine green (ICG) retention was performed, and ICG-K and ICG-R15 were recorded. Child-Pugh (CP) scores were carried out based on patient’s preoperative biochemical tests and physical condition. Correlations among CP scores, ICG-R15, ICG-K and LS values were observed and analyzed using either the Pearson correlation coefficient or the Spearman rank correlation coefficient. Kruskal-Wallis test was used to compare LS values of CP scores, and the receiver-operator characteristic (ROC) curve was used to analyze liver reserve function assessment accuracy. RESULTS: LS in the ICG-R15 10%-20% group was significantly higher than in the ICG-R15 < 10% group; and the difference was statistically significant (2.19 ± 0.27 vs 1.59 ± 0.32, P < 0.01). LS in the ICG-R15 > 20% group was significantly higher than in the ICG-R15 < 10% group; and the difference was statistically significant (2.92 ± 0.29 vs 1.59 ± 0.32, P < 0.01). The LS value in patients with CP class A was lower than in patients with CP class B (1.57 ± 0.34 vs 1.86 ± 0.27, P < 0.05), while the LS value in patients with CP class B was lower than in patients with CP class C (1.86 ± 0.27 vs 2.47 ± 0.33, P < 0.01). LS was positively correlated with ICG-R15 (r = 0.617, P < 0.01) and CP score (r = 0.772, P < 0.01). Meanwhile, LS was negatively correlated with ICG-K (r = -0.673, P < 0.01). AST, ALT and T-Bil were positively correlated with LS, while ALB was negatively correlated with LS (P < 0.05). The ROC curve revealed that the when the LS value was 2.34 m/s, the Youden index was at its highest point, sensitivity was 69.2% and specificity was 92.1%. CONCLUSION: For patients with liver tumors, ARFI imaging is a useful tool for assessing liver reserve function. PMID:26327773
Bipropellant propulsion with reciprocating pumps
NASA Astrophysics Data System (ADS)
Whitehead, John C.
1993-06-01
A pressure regulated gas generator rocket cycle with alternately pressurized pairs of reciprocating pumps offers thrust-on-demand operation with significantly lower inert mass than conventional spacecraft liquid propulsion systems. The operation of bipropellant feed systems with reciprocating pumps is explained, with consideration for both short and long term missions. There are several methods for startup and shutdown of this self-starting pump-fed system, with preference determined by thrust duty cycle and mission duration. Progress to date includes extensive development testing of components unique to this type of system, and several live tests with monopropellant hydrazine. Pneumatic pump control valves which render pistons and bellows automatically responsive to downstream liquid demand are significantly simpler than those described previously. A compact pumpset mounted to central liquid manifolds has a pair of oxidizer pumps pneumatically slaved to a pair of fuel pumps to reduce vibration. A warm gas pressure reducer for tank expulsion can eliminate any remaining need for inert gas storage.
Testing of Liquid Metal Components for Nuclear Surface Power Systems
NASA Technical Reports Server (NTRS)
Polzin, K. A.; Pearson, J. B.; Godfroy, T. J.; Schoenfeld, M.; Webster, K.; Briggs, M. H.; Geng, S. M.; Adkins, H. E.; Werner, J. E.
2010-01-01
The capability to perform testing at both the module/component level and in near prototypic reactor configurations using a non-nuclear test methodology allowed for evaluation of two components critical to the development of a potential nuclear fission power system for the lunar surface. A pair of 1 kW Stirling power convertors, similar to the type that would be used in a reactor system to convert heat to electricity, were integrated into a reactor simulator system to determine their performance using pumped NaK as the hot side working fluid. The performance in the pumped-NaK system met or exceed the baseline performance measurements where the converters were electrically heated. At the maximum hot-side temperature of 550 C the maximum output power was 2375 watts. A specially-designed test apparatus was fabricated and used to quantify the performance of an annular linear induction pump that is similar to the type that could be used to circulate liquid metal through the core of a space reactor system. The errors on the measurements were generally much smaller than the magnitude of the measurements, permitting accurate performance evaluation over a wide range of operating conditions. The pump produced flow rates spanning roughly 0.16 to 5.7 l/s (2.5 to 90 GPM), and delta p levels from less than 1 kPa to 90 kPa (greater than 0.145 psi to roughly 13 psi). At the nominal FSP system operating temperature of 525 C the maximum efficiency was just over 4%.
Teacher Support and Life Satisfaction: An Investigation with Urban, Middle School Students
ERIC Educational Resources Information Center
Guess, Pamela E.; McCane-Bowling, Sara J.
2016-01-01
This study examined the relationship between perceived teacher support and overall life satisfaction (LS) in a sample of urban middle school students. Based on correlations between measures of student perceptions related to these constructs, results indicated that student perceptions of teacher support correlated significantly with LS, with the…
Shao, Yongni; Xie, Chuanqi; Jiang, Linjun; Shi, Jiahui; Zhu, Jiajin; He, Yong
2015-04-05
Visible/near infrared spectroscopy (Vis/NIR) based on sensitive wavelengths (SWs) and chemometrics was proposed to discriminate different tomatoes bred by spaceflight mutagenesis from their leafs or fruits (green or mature). The tomato breeds were mutant M1, M2 and their parent. Partial least squares (PLS) analysis and least squares-support vector machine (LS-SVM) were implemented for calibration models. PLS analysis was implemented for calibration models with different wavebands including the visible region (400-700 nm) and the near infrared region (700-1000 nm). The best PLS models were achieved in the visible region for the leaf and green fruit samples and in the near infrared region for the mature fruit samples. Furthermore, different latent variables (4-8 LVs for leafs, 5-9 LVs for green fruits, and 4-9 LVs for mature fruits) were used as inputs of LS-SVM to develop the LV-LS-SVM models with the grid search technique and radial basis function (RBF) kernel. The optimal LV-LS-SVM models were achieved with six LVs for the leaf samples, seven LVs for green fruits, and six LVs for mature fruits, respectively, and they outperformed the PLS models. Moreover, independent component analysis (ICA) was executed to select several SWs based on loading weights. The optimal LS-SVM model was achieved with SWs of 550-560 nm, 562-574 nm, 670-680 nm and 705-71 5 nm for the leaf samples; 548-556 nm, 559-564 nm, 678-685 nm and 962-974 nm for the green fruit samples; and 712-718 nm, 720-729 nm, 968-978 nm and 820-830 nm for the mature fruit samples. All of them had better performance than PLS and LV-LS-SVM, with the parameters of correlation coefficient (rp), root mean square error of prediction (RMSEP) and bias of 0.9792, 0.2632 and 0.0901 based on leaf discrimination, 0.9837, 0.2783 and 0.1758 based on green fruit discrimination, 0.9804, 0.2215 and -0.0035 based on mature fruit discrimination, respectively. The overall results indicated that ICA was an effective way for the selection of SWs, and the Vis/NIR combined with LS-SVM models had the capability to predict the different breeds (mutant M1, mutant M2 and their parent) of tomatoes from leafs and fruits. Copyright © 2015 Elsevier B.V. All rights reserved.
Hu, Jun; Liu, Zi; Yu, Dong-Jun; Zhang, Yang
2018-02-15
Sequence-order independent structural comparison, also called structural alignment, of small ligand molecules is often needed for computer-aided virtual drug screening. Although many ligand structure alignment programs are proposed, most of them build the alignments based on rigid-body shape comparison which cannot provide atom-specific alignment information nor allow structural variation; both abilities are critical to efficient high-throughput virtual screening. We propose a novel ligand comparison algorithm, LS-align, to generate fast and accurate atom-level structural alignments of ligand molecules, through an iterative heuristic search of the target function that combines inter-atom distance with mass and chemical bond comparisons. LS-align contains two modules of Rigid-LS-align and Flexi-LS-align, designed for rigid-body and flexible alignments, respectively, where a ligand-size independent, statistics-based scoring function is developed to evaluate the similarity of ligand molecules relative to random ligand pairs. Large-scale benchmark tests are performed on prioritizing chemical ligands of 102 protein targets involving 1,415,871 candidate compounds from the DUD-E (Database of Useful Decoys: Enhanced) database, where LS-align achieves an average enrichment factor (EF) of 22.0 at the 1% cutoff and the AUC score of 0.75, which are significantly higher than other state-of-the-art methods. Detailed data analyses show that the advanced performance is mainly attributed to the design of the target function that combines structural and chemical information to enhance the sensitivity of recognizing subtle difference of ligand molecules and the introduces of structural flexibility that help capture the conformational changes induced by the ligand-receptor binding interactions. These data demonstrate a new avenue to improve the virtual screening efficiency through the development of sensitive ligand structural alignments. http://zhanglab.ccmb.med.umich.edu/LS-align/. njyudj@njust.edu.cn or zhng@umich.edu. Supplementary data are available at Bioinformatics online.
Comfortable, high-efficiency heat pump with desiccant-coated, water-sorbing heat exchangers
NASA Astrophysics Data System (ADS)
Tu, Y. D.; Wang, R. Z.; Ge, T. S.; Zheng, X.
2017-01-01
Comfortable, efficient, and affordable heating, ventilation, and air conditioning systems in buildings are highly desirable due to the demands of energy efficiency and environmental friendliness. Traditional vapor-compression air conditioners exhibit a lower coefficient of performance (COP) (typically 2.8-3.8) owing to the cooling-based dehumidification methods that handle both sensible and latent loads together. Temperature- and humidity-independent control or desiccant systems have been proposed to overcome these challenges; however, the COP of current desiccant systems is quite small and additional heat sources are usually needed. Here, we report on a desiccant-enhanced, direct expansion heat pump based on a water-sorbing heat exchanger with a desiccant coating that exhibits an ultrahigh COP value of more than 7 without sacrificing any comfort or compactness. The pump’s efficiency is doubled compared to that of pumps currently used in conventional room air conditioners, which is a revolutionary HVAC breakthrough. Our proposed water-sorbing heat exchanger can independently handle sensible and latent loads at the same time. The desiccants adsorb moisture almost isothermally and can be regenerated by condensation heat. This new approach opens up the possibility of achieving ultrahigh efficiency for a broad range of temperature- and humidity-control applications.
Estimating Aquifer Properties Using Sinusoidal Pumping Tests
NASA Astrophysics Data System (ADS)
Rasmussen, T. C.; Haborak, K. G.; Young, M. H.
2001-12-01
We develop the theoretical and applied framework for using sinusoidal pumping tests to estimate aquifer properties for confined, leaky, and partially penetrating conditions. The framework 1) derives analytical solutions for three boundary conditions suitable for many practical applications, 2) validates the analytical solutions against a finite element model, 3) establishes a protocol for conducting sinusoidal pumping tests, and 4) estimates aquifer hydraulic parameters based on the analytical solutions. The analytical solutions to sinusoidal stimuli in radial coordinates are derived for boundary value problems that are analogous to the Theis (1935) confined aquifer solution, the Hantush and Jacob (1955) leaky aquifer solution, and the Hantush (1964) partially penetrated confined aquifer solution. The analytical solutions compare favorably to a finite-element solution of a simulated flow domain, except in the region immediately adjacent to the pumping well where the implicit assumption of zero borehole radius is violated. The procedure is demonstrated in one unconfined and two confined aquifer units near the General Separations Area at the Savannah River Site, a federal nuclear facility located in South Carolina. Aquifer hydraulic parameters estimated using this framework provide independent confirmation of parameters obtained from conventional aquifer tests. The sinusoidal approach also resulted in the elimination of investigation-derived wastes.
A new NIST primary standardization of 18F.
Fitzgerald, R; Zimmerman, B E; Bergeron, D E; Cessna, J C; Pibida, L; Moreira, D S
2014-02-01
A new primary standardization of (18)F by NIST is reported. The standard is based on live-timed beta-gamma anticoincidence counting with confirmatory measurements by three other methods: (i) liquid scintillation (LS) counting using CIEMAT/NIST (3)H efficiency tracing; (ii) triple-to-double coincidence ratio (TDCR) counting; and (iii) NaI integral counting and HPGe γ-ray spectrometry. The results are reported as calibration factors for NIST-maintained ionization chambers (including some "dose calibrators"). The LS-based methods reveal evidence for cocktail instability for one LS cocktail. Using an ionization chamber to link this work with previous NIST results, the new value differs from the previous reports by about 4%, but appears to be in good agreement with the key comparison reference value (KCRV) of 2005. © 2013 Published by Elsevier Ltd.
Test and Analysis Correlation of Form Impact onto Space Shuttle Wing Leading Edge RCC Panel 8
NASA Technical Reports Server (NTRS)
Fasanella, Edwin L.; Lyle, Karen H.; Gabrys, Jonathan; Melis, Matthew; Carney, Kelly
2004-01-01
Soon after the Columbia Accident Investigation Board (CAIB) began their study of the space shuttle Columbia accident, "physics-based" analyses using LS-DYNA were applied to characterize the expected damage to the Reinforced Carbon-Carbon (RCC) leading edge from high-speed foam impacts. Forensic evidence quickly led CAIB investigators to concentrate on the left wing leading edge RCC panels. This paper will concentrate on the test of the left-wing RCC panel 8 conducted at Southwest Research Institute (SwRI) and the correlation with an LS-DYNA analysis. The successful correlation of the LS-DYNA model has resulted in the use of LS-DYNA as a predictive tool for characterizing the threshold of damage for impacts of various debris such as foam, ice, and ablators onto the RCC leading edge for shuttle return-to-flight.
Multisource image fusion method using support value transform.
Zheng, Sheng; Shi, Wen-Zhong; Liu, Jian; Zhu, Guang-Xi; Tian, Jin-Wen
2007-07-01
With the development of numerous imaging sensors, many images can be simultaneously pictured by various sensors. However, there are many scenarios where no one sensor can give the complete picture. Image fusion is an important approach to solve this problem and produces a single image which preserves all relevant information from a set of different sensors. In this paper, we proposed a new image fusion method using the support value transform, which uses the support value to represent the salient features of image. This is based on the fact that, in support vector machines (SVMs), the data with larger support values have a physical meaning in the sense that they reveal relative more importance of the data points for contributing to the SVM model. The mapped least squares SVM (mapped LS-SVM) is used to efficiently compute the support values of image. The support value analysis is developed by using a series of multiscale support value filters, which are obtained by filling zeros in the basic support value filter deduced from the mapped LS-SVM to match the resolution of the desired level. Compared with the widely used image fusion methods, such as the Laplacian pyramid, discrete wavelet transform methods, the proposed method is an undecimated transform-based approach. The fusion experiments are undertaken on multisource images. The results demonstrate that the proposed approach is effective and is superior to the conventional image fusion methods in terms of the pertained quantitative fusion evaluation indexes, such as quality of visual information (Q(AB/F)), the mutual information, etc.
Barac, Aleksandra; Pekmezovic, Marina; Milobratovic, Danica; Otasevic-Tasic, Suzana; Radunovic, Milena; Arsic Arsenijevic, Valentina
2015-02-01
Malassezia yeast belongs to the normal cutaneous flora and under certain conditions it causes seborrhoeic dermatitis (SD). There is no culture-based study about the presence and density of the Malassezia in SD patients in Serbia. Aim was to show the presence, species distribution and density of Malassezia in patients with SD on lesional skin (LS) and non-lesional skin (NLS) and healthy controls (HC) and to compare data between Serbia and other countries. The study included 70 HC and 60 patients with SD in the study group (SG). Isolation, identification and examination of density of Malassezia colony-forming units from LS and NLS were performed. Malassezia was found more frequently in the SG than in HC, 90% and 60%, respectively (P < 0.01). The most frequent isolates in SG on LS were M. slooffiae (26%), followed by M. globosa (17%) and M. sympodialis (17%). The yeast density was much higher on LS of SG than on NLS of SG or in the HC group (P < 0.05). Higher density of Malassezia was shown on LS of SG than on NLS of SG and HC. M. slooffiae is the most prevalent species in SD patients in Serbia. This study demonstrated a positive relationship between severity of SD and presence of Malassezia spp. © 2015 Blackwell Verlag GmbH.
Elkhodairy, Kadria A.; Elsaghir, Hanna A.; Al-Subayiel, Amal M.
2014-01-01
The present study aimed at the formulation of matrix tablets for colon-specific drug delivery (CSDD) system of indomethacin (IDM) by applying liquisolid (LS) technique. A CSDD system based on time-dependent polymethacrylates and enzyme degradable polysaccharides was established. Eudragit RL 100 (E-RL 100) was employed as time-dependent polymer, whereas bacterial degradable polysaccharides were presented as LS systems loaded with the drug. Indomethacin-loaded LS systems were prepared using different polysaccharides, namely, guar gum (GG), pectin (PEC), and chitosan (CH), as carriers separately or in mixtures of different ratios of 1 : 3, 1 : 1, and 3 : 1. Liquisolid systems that displayed promising results concerning drug release rate in both pH 1.2 and pH 6.8 were compressed into tablets after the addition of the calculated amount of E-RL 100 and lubrication with magnesium stearate and talc in the ratio of 1 : 9. It was found that E-RL 100 improved the flowability and compressibility of all LS formulations. The release data revealed that all formulations succeeded to sustain drug release over a period of 24 hours. Stability study indicated that PEC-based LS system as well as its matrix tablets was stable over the period of storage (one year) and could provide a minimum shelf life of two years. PMID:24971345
Phummiphan, Itthikorn; Horpibulsuk, Suksun; Rachan, Runglawan; Arulrajah, Arul; Shen, Shui-Long; Chindaprasirt, Prinya
2018-01-05
Granulated Blast Furnace Slag (GBFS) was used as a replacement material in marginal lateritic soil (LS) while class C Fly Ash (FA) was used as a precursor for the geopolymerization process to develop a low-carbon pavement base material at ambient temperature. Unconfined Compression Strength (UCS) tests were performed to investigate the strength development of geopolymer stabilized LS/GBFS blends. Scanning Electron Microscopy and X-ray Diffraction analysis were undertaken to examine the role of the various influencing factors on UCS development. The influencing factors studied included GBFS content, Na 2 SiO 3 :NaOH ratio (NS:NH) and curing time. The 7-day soaked UCS of FA geopolymer stabilized LS/GBFS blends at various NS:NH ratios tested was found to satisfy the specifications of the Thailand national road authorities. The GBFS replacement was found to be insignificant for the improvement of the UCS of FA geopolymer stabilized LS/GBFS blends at low NS:NH ratio of 50:50. Microstructural analysis indicated the coexistence of Calcium Silicate Hydrate (CSH) and Sodium Alumino Silicate Hydrate products in FA geopolymer stabilized LS/GBFS blends. This research enables GBFS, which is traditionally considered as a waste material, to be used as a replacement and partially reactive material in FA geopolymer pavement applications. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Xin, Ni; Gu, Xiao-Feng; Wu, Hao; Hu, Yu-Zhu; Yang, Zhong-Lin
2012-04-01
Most herbal medicines could be processed to fulfill the different requirements of therapy. The purpose of this study was to discriminate between raw and processed Dipsacus asperoides, a common traditional Chinese medicine, based on their near infrared (NIR) spectra. Least squares-support vector machine (LS-SVM) and random forests (RF) were employed for full-spectrum classification. Three types of kernels, including linear kernel, polynomial kernel and radial basis function kernel (RBF), were checked for optimization of LS-SVM model. For comparison, a linear discriminant analysis (LDA) model was performed for classification, and the successive projections algorithm (SPA) was executed prior to building an LDA model to choose an appropriate subset of wavelengths. The three methods were applied to a dataset containing 40 raw herbs and 40 corresponding processed herbs. We ran 50 runs of 10-fold cross validation to evaluate the model's efficiency. The performance of the LS-SVM with RBF kernel (RBF LS-SVM) was better than the other two kernels. The RF, RBF LS-SVM and SPA-LDA successfully classified all test samples. The mean error rates for the 50 runs of 10-fold cross validation were 1.35% for RBF LS-SVM, 2.87% for RF, and 2.50% for SPA-LDA. The best classification results were obtained by using LS-SVM with RBF kernel, while RF was fast in the training and making predictions.
AGO Austria recommendation on screening and diagnosis of Lynch syndrome (LS).
Zeimet, Alain G; Mori, Harald; Petru, Edgar; Polterauer, Stephan; Reinthaller, Alexander; Schauer, Christian; Scholl-Firon, Tonja; Singer, Christian; Wimmer, Katharina; Zschocke, Johannes; Marth, Christian
2017-07-01
This manuscript reports the consensus recommendations on screening and diagnosis of Lynch syndrome (LS) in patients with endometrial or ovarian cancer as well as on possible preventive measures in effectively LS-diagnosed women. The recommendations are issued by the Austrian Arbeitsgemeinschaft für Gynäkologische Onkologie (AGO) of the Österreichischen Gesellschaft für Gynäkologie und Geburtshilfe (OEGGG) after consultation of the most recent and relevant literature and following deliberation by the Genetic Task-Force convoked May, 2015 by the AGO Council. The Austrian AGO recommends immunohistochemical tissue screening for type-I and type-II endometrial cancers in all patients below the age of 70 years, and for all endometrioid and clear-cell ovarian cancers independently of the patient's age. If needed immunohistochemistry should be complemented by tissue MLH1 promotor hypermethylation testing and/or microsatellite instability (MSI) analysis. The diagnosis LS requires confirmation through identification of a germline mutation by a molecular genetic examination in the mismatch repair genes using the patient's blood. This should be performed without preceding tissue screening when in LS-associated cancer patients the family history fulfills the Amsterdam II or the revised Bethesda criteria. In LS-diagnosed women, the age for prophylactic surgery should be set flexibly based on an informed consent. Regarding the monitoring of these women, chemo-preventive measures as well as screening procedures either to avoid or to early detect LS-related tumors are discussed with a special light on their specific limitations.
LS Bound based gene selection for DNA microarray data.
Zhou, Xin; Mao, K Z
2005-04-15
One problem with discriminant analysis of DNA microarray data is that each sample is represented by quite a large number of genes, and many of them are irrelevant, insignificant or redundant to the discriminant problem at hand. Methods for selecting important genes are, therefore, of much significance in microarray data analysis. In the present study, a new criterion, called LS Bound measure, is proposed to address the gene selection problem. The LS Bound measure is derived from leave-one-out procedure of LS-SVMs (least squares support vector machines), and as the upper bound for leave-one-out classification results it reflects to some extent the generalization performance of gene subsets. We applied this LS Bound measure for gene selection on two benchmark microarray datasets: colon cancer and leukemia. We also compared the LS Bound measure with other evaluation criteria, including the well-known Fisher's ratio and Mahalanobis class separability measure, and other published gene selection algorithms, including Weighting factor and SVM Recursive Feature Elimination. The strength of the LS Bound measure is that it provides gene subsets leading to more accurate classification results than the filter method while its computational complexity is at the level of the filter method. A companion website can be accessed at http://www.ntu.edu.sg/home5/pg02776030/lsbound/. The website contains: (1) the source code of the gene selection algorithm; (2) the complete set of tables and figures regarding the experimental study; (3) proof of the inequality (9). ekzmao@ntu.edu.sg.
Nano-fabricated size exclusion chromatograph
NASA Technical Reports Server (NTRS)
Svehla, D.; Feldman, S.; Feldman, J.; Grunthaner, F.; Shakkottai, P.; Castillo, L. del; White, V.
2002-01-01
This paper describes the development of a nano-fabricated size exclusion chromatograph (nSEC) based on the principle that molecules traveling through amicrocolumn containing nano-fabricated features will have characteristic elution times that directly correlate to molecular weight. Compared to conventional size exclusion chromatography, the nSEC offers greater control over the size exclusion process; mass fabrication; integration of the separation column with associated valves, pumps, and detectors; and dramatic reductions in instrument mass and power requirements.
Liu, Xue-Mei; Liu, Jian-She
2012-11-01
Visible infrared spectroscopy (Vis/SW-NIRS) was investigated in the present study for measurement accuracy of soil properties,namely, available nitrogen(N) and available potassium(K). Three types of pretreatments including standard normal variate (SNV), multiplicative scattering correction (MSC) and Savitzky-Golay smoothing+first derivative were adopted to eliminate the system noises and external disturbances. Then partial least squares (PLS) and least squares-support vector machine (LS-SVM) models analysis were implemented for calibration models. Simultaneously, the performance of least squares-support vector machine (LS-SVM) models was compared with three kinds of inputs, including PCA(PCs), latent variables (LVs), and effective wavelengths (EWs). The results indicated that all LS-SVM models outperformed PLS models. The performance of the model was evaluated by the correlation coefficient (r2) and RMSEP. The optimal EWs-LS-SVM models were achieved, and the correlation coefficient (r2) and RMSEP were 0.82 and 17.2 for N and 0.72 and 15.0 for K, respectively. The results indicated that visible and short wave-near infrared spectroscopy (Vis/SW-NIRS)(325-1 075 nm) combined with LS-SVM could be utilized as a precision method for the determination of soil properties.
Life satisfaction and cardiovascular disease risk in Poland
Szklarska, Alicja; Lipowicz, Anna; Jankowska, Ewa Anita; Kozieł, Sławomir
2013-01-01
Introduction Cardiovascular disease is the most common cause of death. Life satisfaction is a predictor of morbidity and mortality, irrespectively of objective measures of health status. The aim of the study was to evaluate the relationship between life satisfaction (LS) and cardiovascular disease risk (CVD) assessed with the Framingham Risk Score (FRS) in Polish adults. Material and methods Past, present and projected LS were estimated. The FRS reflecting 10-year CVD risk was calculated from health indices and lifestyle parameters. Relationships between LS and FRS were tested by two-way analysis of variance in 489 men and 591 women, 40–50 years of age. Results Subjects with a reduction in LS over time had a higher FRS compared to peers with an improvement in LS. The relationship between current LS and FRS had a J-shape in men; FRS was lowest in men with an LS of 5–7 (average LS), slightly higher in men with an LS of 8–10 (highest LS), and highest in men with an LS of 1–4 (lowest LS). Among women, there was an inverse linear relationship between LS and FRS: the higher the LS, the lower FRS. There was a strong linear relationship between predicted LS and CVD risk. Highest risk was evident in subjects with low LS in whom low LS was predicted over the next five years. Conclusions Low LS (dissatisfaction) thus has a long-term negative effect on CVD risk in Polish adults of both sexes. PMID:24049521
Kobayashi, Erika; Liang, Jersey; Sugawara, Ikuko; Fukaya, Taro; Shinkai, Shoji; Akiyama, Hiroko
2015-12-01
Japanese older people experienced drastic changes in family structure and values after World War II at different life stages by birth cohorts. We examined how linkages between different types of social ties and life satisfaction (LS) vary across cohorts, in conjunction with age and survey year differences. Data from face-to-face interviews conducted in 1987, 1999, and 2012 with a nationally representative sample of older Japanese (N = 4,917) were analyzed. The participants were members of 4 birth cohorts (C1: 1901-1912, C2: 1913-1924, C3: 1925-1936, C4: 1937-1949), categorized into 6 groups based on cohort and age at time of measurement (young-old [YO]: 63-74; old-old [OO]: 75-86): C1OO, C2YO, C2OO, C3YO, C3OO, and C4YO. Effects of social networks on LS among the 6 groups were compared simultaneously and separately by gender using the Amos software. There were significant cohort variations in the linkages between family network and LS. The positive association between being married and LS was stronger for later cohorts (C3, C4) among men, whereas that of co-residence with a child and LS was stronger for the earlier cohorts (C1, C2) among women. Moreover, the positive association between meeting with nonfamily members and LS increased from 1987 to 2012 among women, indicating a period effect over a cohort effect. The effects of being married and participation in community groups on LS also changed with age. Our results suggest that linkages between social relations and LS should be interpreted within the context of individual and social changes over time. (c) 2015 APA, all rights reserved).
Very high cloud detection in more than two decades of HIRS data
NASA Astrophysics Data System (ADS)
Kolat, Utkan; Menzel, W. Paul; Olson, Erik; Frey, Richard
2013-04-01
This paper reports on the use of High-resolution Infrared Radiation Sounder (HIRS) measurements to infer the presence of upper tropospheric and lower stratospheric (UT/LS) clouds. UT/LS cloud detection is based on the fact that, when viewing an opaque UT/LS cloud that fills the sensor field of view, positive lapse rates above the tropopause cause a more absorbing CO2 or H2O-sensitive spectral band to measure a brightness temperature warmer than that of a less absorbing or nearly transparent infrared window spectral band. The HIRS sensor has flown on 16 polar-orbiting satellites from TIROS-N through NOAA-19 and Metop-A and -B, forming the only 30 year record that includes H2O and CO2-sensitive spectral bands enabling the detection of these UT/LS clouds. Comparison with collocated Cloud-Aerosol Lidar with Orthogonal Polarization data reveals that 97% of the HIRS UT/LS cloud determinations are within 2.5 km of the tropopause (defined as the coldest level in the National Centers for Environmental Prediction Global Data Assimilation System); more clouds are found above the tropopause than below. From NOAA-14 data spanning 1995 through 2005, we find indications of UT/LS clouds in 0.7% of the observations from 60N to 60S using CO2 absorption bands; however, in the region of the Inter-Tropical Convergence Zone (ITCZ), this increases to 1.7%. During El Niño years, UT/LS clouds shift eastward out of their normal location in the western Pacific region. Monthly trends from 1987 through 2011 using data from NOAA-10 onwards show decreases in UT/LS cloud detection in the region of the ITCZ from 1987 until 1996, increases until 2001, and decreases thereafter.
Kong, Desheng; Wang, Yan; Ji, Ping; Li, Wei; Ying, Tianlei; Huang, Jinghe; Wang, Chen; Wu, Yanling; Wang, Yanping; Chen, Weizao; Hao, Yanling; Hong, Kunxue; Shao, Yiming; Dimitrov, Dimiter S; Jiang, Shibo; Ma, Liying
2018-05-11
Current treatments cannot completely eradicate HIV-1 owing to the presence of latently infected cells which harbor transcriptionally silent HIV-1. However, defucosylated antibodies can readily kill latently infected cells after their activation to express envelope glycoprotein (Env) through antibody-dependent cellular cytotoxicity (ADCC). We herein aimed to test a defucosylated bispecific multivalent molecule consisting of domain-antibody and single-domain CD4, LSEVh-LS-F, for its HIV-1 neutralizing activity and ADCC against the reactivated latently infected cells, compared with the non-defucosylated molecule LSEVh-LS. LSEVh-LS-F's neutralizing activity against a panel of newly characterized Chinese HIV-1 clinical isolates was assessed by using TZM-bl- and PBMC-based assays. LSEVh-LS-F-mediated ADCC in the presence of NK cells against cell lines that stably express Env proteins, HIV-1-infected cells and LRA-reactivated HIV-1 latent cells, was measured using a lactate dehydrogenase (LDH) cytotoxicity assay or flow cytometry. LSEVh-LS-F and LSEVh-LS were equally effective in neutralized infection of all HIV-1 isolates tested with IC50 and IC90 values 3∼4-fold lower than those of VRC01. LSEVh-LS-F was more effective in NK-mediated killing of HIV-1 Env-expressing cell lines, HIV-1-infected cells, latency reactivation agents-reactivated ACH2 cells, and reactivated latently infected resting CD4 T cell line as well as resting CD4 T lymphocytes isolated from patients receiving highly active anti-retroviral therapy (HAART). LSEVh-LS-F exhibits broad HIV-1 neutralizing activity and enhanced ADCC against HIV-1-infected cells, reactivated latently infected cell lines and primary CD4 T cells, thus being a promising candidate therapeutic for eradicating the HIV-1 reservoir.
Fatigue failure of dentin-composite disks subjected to cyclic diametral compression
Li, Yuping; Carrera, Carola; Chen, Ruoqiong; Li, Jianying; Chen, Yungchung; Lenton, Patricia; Rudney, Joel. D.; Jones, Robert S.; Aparicio, Conrado; Fok, Alex
2015-01-01
Objective Our aim was to establish the relationship between cyclic loading and fatigue life of the dentin-composite interface using the newly developed disk in diametral compression tests. The results were then used to estimate the fatigue life of restored teeth under occlusal loading. Methods Disk specimens (5mm dia. × 2mm thick) were prepared using bovine incisors and restored with either a methacrylate-based composite Z100™ with Adper Single Bond Plus (Z100) or silorane-based composite Filtek ™ LS with LS System adhesive (LS). The dentin-composite disks were tested under cyclic diametral compression to determine the number of cycles to failure (Nf) at three load levels (n = 3 per group). Finite element analysis (FEA) was used to calculate the interfacial stresses (σ) within the specimen, to establish the σ vs. Nf curves, and those within a restored tooth under normal chewing forces (15N maximum). These were then used to estimate the lifetime of the restored tooth for the two restorative systems. Results The disks restored with LS had a higher fatigue resistance than those restored with Z100. The maximum interfacial stress in the restored tooth determined by FEA was ∼0.5MPa. Based on the estimate of 300,000 cycles of chewing per year, the predicted lifetime under occlusal loading for teeth restored with LS and Z100 was 33 and 10 years, respectively. Significance The disk in cyclic diametral compression has been used successfully to provide fatigue data which allows the lifetime of composite-restored teeth under occlusal loading to be predicted using numerical simulation. PMID:25958269
Valdés-Martiní, José R; Marrero-Ponce, Yovani; García-Jacas, César R; Martinez-Mayorga, Karina; Barigye, Stephen J; Vaz d'Almeida, Yasser Silveira; Pham-The, Hai; Pérez-Giménez, Facundo; Morell, Carlos A
2017-06-07
In previous reports, Marrero-Ponce et al. proposed algebraic formalisms for characterizing topological (2D) and chiral (2.5D) molecular features through atom- and bond-based ToMoCoMD-CARDD (acronym for Topological Molecular Computational Design-Computer Aided Rational Drug Design) molecular descriptors. These MDs codify molecular information based on the bilinear, quadratic and linear algebraic forms and the graph-theoretical electronic-density and edge-adjacency matrices in order to consider atom- and bond-based relations, respectively. These MDs have been successfully applied in the screening of chemical compounds of different therapeutic applications ranging from antimalarials, antibacterials, tyrosinase inhibitors and so on. To compute these MDs, a computational program with the same name was initially developed. However, this in house software barely offered the functionalities required in contemporary molecular modeling tasks, in addition to the inherent limitations that made its usability impractical. Therefore, the present manuscript introduces the QuBiLS-MAS (acronym for Quadratic, Bilinear and N-Linear mapS based on graph-theoretic electronic-density Matrices and Atomic weightingS) software designed to compute topological (0-2.5D) molecular descriptors based on bilinear, quadratic and linear algebraic forms for atom- and bond-based relations. The QuBiLS-MAS module was designed as standalone software, in which extensions and generalizations of the former ToMoCoMD-CARDD 2D-algebraic indices are implemented, considering the following aspects: (a) two new matrix normalization approaches based on double-stochastic and mutual probability formalisms; (b) topological constraints (cut-offs) to take into account particular inter-atomic relations; (c) six additional atomic properties to be used as weighting schemes in the calculation of the molecular vectors; (d) four new local-fragments to consider molecular regions of interest; (e) number of lone-pair electrons in chemical structure defined by diagonal coefficients in matrix representations; and (f) several aggregation operators (invariants) applied over atom/bond-level descriptors in order to compute global indices. This software permits the parallel computation of the indices, contains a batch processing module and data curation functionalities. This program was developed in Java v1.7 using the Chemistry Development Kit library (version 1.4.19). The QuBiLS-MAS software consists of two components: a desktop interface (GUI) and an API library allowing for the easy integration of the latter in chemoinformatics applications. The relevance of the novel extensions and generalizations implemented in this software is demonstrated through three studies. Firstly, a comparative Shannon's entropy based variability study for the proposed QuBiLS-MAS and the DRAGON indices demonstrates superior performance for the former. A principal component analysis reveals that the QuBiLS-MAS approach captures chemical information orthogonal to that codified by the DRAGON descriptors. Lastly, a QSAR study for the binding affinity to the corticosteroid-binding globulin using Cramer's steroid dataset is carried out. From these analyses, it is revealed that the QuBiLS-MAS approach for atom-pair relations yields similar-to-superior performance with regard to other QSAR methodologies reported in the literature. Therefore, the QuBiLS-MAS approach constitutes a useful tool for the diversity analysis of chemical compound datasets and high-throughput screening of structure-activity data.
High-power, fixed, and tunable wavelength, grating-free cascaded Raman fiber lasers.
Balaswamy, V; Arun, S; Aparanji, Santosh; Choudhury, Vishal; Supradeepa, V R
2018-04-01
Cascaded Raman lasers enable high powers at various wavelength bands inaccessible with conventional rare-earth-doped lasers. The input and output wavelengths of conventional implementations are fixed by the constituent fiber gratings necessary for cascaded Raman conversion. We demonstrate here a simple architecture for high-power, fixed, and wavelength tunable, grating-free, cascaded Raman conversion between different wavelength bands. The architecture is based on the recently proposed distributed feedback Raman lasers. Here, we implement a module which converts the ytterbium band to the eye-safe 1.5 μm region. We demonstrate pump-limited output powers of over 30 W in fixed and continuously wavelength tunable configurations.
NASA Astrophysics Data System (ADS)
Clunie, David A.
2000-05-01
Proprietary compression schemes have a cost and risk associated with their support, end of life and interoperability. Standards reduce this cost and risk. The new JPEG-LS process (ISO/IEC 14495-1), and the lossless mode of the proposed JPEG 2000 scheme (ISO/IEC CD15444-1), new standard schemes that may be incorporated into DICOM, are evaluated here. Three thousand, six hundred and seventy-nine (3,679) single frame grayscale images from multiple anatomical regions, modalities and vendors, were tested. For all images combined JPEG-LS and JPEG 2000 performed equally well (3.81), almost as well as CALIC (3.91), a complex predictive scheme used only as a benchmark. Both out-performed existing JPEG (3.04 with optimum predictor choice per image, 2.79 for previous pixel prediction as most commonly used in DICOM). Text dictionary schemes performed poorly (gzip 2.38), as did image dictionary schemes without statistical modeling (PNG 2.76). Proprietary transform based schemes did not perform as well as JPEG-LS or JPEG 2000 (S+P Arithmetic 3.4, CREW 3.56). Stratified by modality, JPEG-LS compressed CT images (4.00), MR (3.59), NM (5.98), US (3.4), IO (2.66), CR (3.64), DX (2.43), and MG (2.62). CALIC always achieved the highest compression except for one modality for which JPEG-LS did better (MG digital vendor A JPEG-LS 4.02, CALIC 4.01). JPEG-LS outperformed existing JPEG for all modalities. The use of standard schemes can achieve state of the art performance, regardless of modality, JPEG-LS is simple, easy to implement, consumes less memory, and is faster than JPEG 2000, though JPEG 2000 will offer lossy and progressive transmission. It is recommended that DICOM add transfer syntaxes for both JPEG-LS and JPEG 2000.
Nicaise, Valérie; German-Retana, Sylvie; Sanjuán, Raquel; Dubrana, Marie-Pierre; Mazier, Marianne; Maisonneuve, Brigitte; Candresse, Thierry; Caranta, Carole; LeGall, Olivier
2003-01-01
The eIF4E and eIF(iso)4E cDNAs from several genotypes of lettuce (Lactuca sativa) that are susceptible, tolerant, or resistant to infection by Lettuce mosaic virus (LMV; genus Potyvirus) were cloned and sequenced. Although Ls-eIF(iso)4E was monomorphic in sequence, three types of Ls-eIF4E differed by point sequence variations, and a short in-frame deletion in one of them. The amino acid variations specific to Ls-eIF4E1 and Ls-eIF4E2 were predicted to be located near the cap recognition pocket in a homology-based tridimensional protein model. In 19 lettuce genotypes, including two near-isogenic pairs, there was a strict correlation between these three allelic types and the presence or absence of the recessive LMV resistance genes mo11 and mo12. Ls-eIF4E1 and mo11 cosegregated in the progeny of two separate crosses between susceptible genotypes and an mo11 genotype. Finally, transient ectopic expression of Ls-eIF4E restored systemic accumulation of a green fluorescent protein-tagged LMV in LMV-resistant mo12 plants and a recombinant LMV expressing Ls-eIF4E° from its genome, but not Ls-eIF4E1 or Ls-eIF(iso)4E, accumulated and produced symptoms in mo11 or mo12 genotypes. Therefore, sequence correlation, tight genetic linkage, and functional complementation strongly suggest that eIF4E plays a role in the LMV cycle in lettuce and that mo11 and mo12 are alleles coding for forms of eIF4E unable or less effective to fulfill this role. More generally, the isoforms of eIF4E appear to be host factors involved in the cycle of potyviruses in plants, probably through a general mechanism yet to be clarified. PMID:12857809
NASA Astrophysics Data System (ADS)
Iorsh, Ivan; Glauser, Marlene; Rossbach, Georg; Levrat, Jacques; Cobet, Munise; Butté, Raphaël; Grandjean, Nicolas; Kaliteevski, Mikhail A.; Abram, Richard A.; Kavokin, Alexey V.
2012-09-01
The main emission characteristics of electrically driven polariton lasers based on planar GaN microcavities with embedded InGaN quantum wells are studied theoretically. The polariton emission dependence on pump current density is first modeled using a set of semiclassical Boltzmann equations for the exciton polaritons that are coupled to the rate equation describing the electron-hole plasma population. Two experimentally relevant pumping geometries are considered, namely the direct injection of electrons and holes into the strongly coupled microcavity region and intracavity optical pumping via an embedded light-emitting diode. The theoretical framework allows the determination of the minimum threshold current density Jthr,min as a function of lattice temperature and exciton-cavity photon detuning for the two pumping schemes. A Jthr,min value of 5 and 6 A cm-2 is derived for the direct injection scheme and for the intracavity optical pumping one, respectively, at room temperature at the optimum detuning. Then an approximate quasianalytical model is introduced to derive solutions for both the steady-state and high-speed current modulation. This analysis makes it possible to show that the exciton population, which acts as a reservoir for the stimulated relaxation process, gets clamped once the condensation threshold is crossed, a behavior analogous to what happens in conventional laser diodes with the carrier density above threshold. Finally, the modulation transfer function is calculated for both pumping geometries and the corresponding cutoff frequency is determined.
An evaluation of a hubless inducer and a full flow hydraulic turbine driven inducer boost pump
NASA Technical Reports Server (NTRS)
Lindley, B. K.; Martinson, A. R.
1971-01-01
The purpose of the study was to compare the performance of several configurations of hubless inducers with a hydrodynamically similar conventional inducer and to demonstrate the performance of a full flow hydraulic turbine driven inducer boost pump using these inducers. A boost pump of this type consists of an inducer connected to a hydraulic turbine with a high speed rotor located in between. All the flow passes through the inducer, rotor, and hydraulic turbine, then into the main pump. The rotor, which is attached to the main pump shaft, provides the input power to drive the hydraulic turbine which, in turn, drives the inducer. The inducer, rotating at a lower speed, develops the necessary head to prevent rotor cavitation. The rotor speed is consistent with present main engine liquid hydrogen pump designs and the overall boost pump head rise is sufficient to provide adequate main pump suction head. This system would have the potential for operating at lower liquid hydrogen tank pressures.
Pump polarization insensitive and efficient laser-diode pumped Yb:KYW ultrafast oscillator.
Wang, Sha; Wang, Yan-Biao; Feng, Guo-Ying; Zhou, Shou-Huan
2016-02-01
We theoretically and experimentally report and evaluate a novel split laser-diode (LD) double-end pumped Yb:KYW ultrafast oscillator aimed at improving the performance of an ultrafast laser. Compared to a conventional unpolarized single-LD end-pumped ultrafast laser system, we improve the laser performance such as absorption efficiency, slope efficiency, cw mode-locking threshold, and output power by this new structure LD-pumped Yb:KYW ultrafast laser. Experiments were carried out with a 1 W output fiber-coupled LD. Experimental results show that the absorption increases from 38.7% to 48.4%, laser slope efficiency increases from 18.3% to 24.2%, cw mode-locking threshold decreases 12.7% from 630 to 550 mW in cw mode-locking threshold, and maximum output-power increases 28.5% from 158.4 to 221.5 mW when we switch the pump scheme from an unpolarized single-end pumping structure to a split LD double-end pumping structure.
Improvement of pump tubes for gas guns and shock tube drivers
NASA Technical Reports Server (NTRS)
Bogdanoff, D. W.
1990-01-01
In a pump tube, a gas is mechanically compressed, producing very high pressures and sound speeds. The intensely heated gas produced in such a tube can be used to drive light gas guns and shock tubes. Three concepts are presented that have the potential to allow substantial reductions in the size and mass of the pump tube to be achieved. The first concept involves the use of one or more diaphragms in the pump tube, thus replacing a single compression process by multiple, successive compressions. The second concept involves a radical reduction in the length-to-diameter ratio of the pump tube and the pump tube piston. The third concept involves shock heating of the working gas by high explosives in a cyclindrical geometry reusable device. Preliminary design analyses are performed on all three concepts and they appear to be quite feasible. Reductions in the length and mass of the pump tube by factors up to about 11 and about 7, respectively, are predicted, relative to a benchmark conventional pump tube.
Interoperative efficiency in minimally invasive surgery suites.
van Det, M J; Meijerink, W J H J; Hoff, C; Pierie, J P E N
2009-10-01
Performing minimally invasive surgery (MIS) in a conventional operating room (OR) requires additional specialized equipment otherwise stored outside the OR. Before the procedure, the OR team must collect, prepare, and connect the equipment, then take it away afterward. These extra tasks pose a thread to OR efficiency and may lengthen turnover times. The dedicated MIS suite has permanently installed laparoscopic equipment that is operational on demand. This study presents two experiments that quantify the superior efficiency of the MIS suite in the interoperative period. Preoperative setup and postoperative breakdown times in the conventional OR and the MIS suite in an experimental setting and in daily practice were analyzed. In the experimental setting, randomly chosen OR teams simulated the setup and breakdown for a standard laparoscopic cholecystectomy (LC) and a complex laparoscopic sigmoid resection (LS). In the clinical setting, the interoperative period for 66 LCs randomly assigned to the conventional OR or the MIS suite were analyzed. In the experimental setting, the setup and breakdown times were significantly shorter in the MIS suite. The difference between the two types of OR increased for the complex procedure: 2:41 min for the LC (p < 0.001) and 10:47 min for the LS (p < 0.001). In the clinical setting, the setup and breakdown times as a whole were not reduced in the MIS suite. Laparoscopic setup and breakdown times were significantly shorter in the MIS suite (mean difference, 5:39 min; p < 0.001). Efficiency during the interoperative period is significantly improved in the MIS suite. The OR nurses' tasks are relieved, which may reduce mental and physical workload and improve job satisfaction and patient safety. Due to simultaneous tasks of other disciplines, an overall turnover time reduction could not be achieved.
Taniguchi, Tatsunori; Ohtani, Tomohito; Kioka, Hidetaka; Tsukamoto, Yasumasa; Onishi, Toshinari; Nakamoto, Kei; Katsimichas, Themistoklis; Sengoku, Kaoruko; Chimura, Misato; Hashimoto, Haruko; Yamaguchi, Osamu; Sawa, Yoshiki; Sakata, Yasushi
2018-01-12
This study sought to investigate whether elevated liver stiffness (LS) values at discharge reflect residual liver congestion and are associated with worse outcomes in patients with heart failure (HF). Transient elastography is a newly developed, noninvasive method for assessing LS, which can be highly reflective of right-sided filling pressure associated with passive liver congestion in patients with HF. LS values were determined for 171 hospitalized patients with HF before discharge using a Fibroscan device. The median LS value was 5.6 kPa (interquartile range: 4.4 to 8.1; range 2.4 to 39.7) and that of right-sided filling pressure, which was estimated based on LS, was 5.7 mm Hg (interquartile range: 4.1 to 8.2 mm Hg; range 0.1 to 18.9 mm Hg). The patients in the highest LS tertile (>6.9 kPa, corresponding to an estimated right-sided filling pressure of >7.1 mm Hg) had advanced New York Heart Association functional class, high prevalence of jugular venous distention and moderate/severe tricuspid regurgitation, large inferior vena cava (IVC) diameter, low hemoglobin and hematocrit levels, high serum direct bilirubin level, and a similar left ventricular ejection fraction compared with the lower tertiles. During follow-up periods (median: 203 days), 8 (5%) deaths and 33 (19%) hospitalizations for HF were observed. The patients in the highest LS group had a significantly higher mortality rate and HF rehospitalization (hazard ratio: 3.57; 95% confidence interval: 1.93 to 6.83; p < 0.001) compared with the other tertiles. Although LS correlated with IVC diameter and serum direct bilirubin and brain natriuretic peptide levels, LS values were predictive of worse outcomes, even after adjustment for these indices. These data suggest that LS is a useful index for assessing systemic volume status and predicting the severity of HF, and that the presence of liver congestion at discharge is associated with worse outcomes in patients with HF. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Universal screening of both endometrial and colon cancers increases the detection of Lynch syndrome.
Adar, Tomer; Rodgers, Linda H; Shannon, Kristen M; Yoshida, Makoto; Ma, Tianle; Mattia, Anthony; Lauwers, Gregory Y; Iafrate, Anthony J; Hartford, Nicole M; Oliva, Esther; Chung, Daniel C
2018-05-11
Lynch syndrome (LS) is the most common hereditary cause of colorectal cancer (CRC) and endometrial cancer (EC). Screening of all CRCs for LS is currently recommended, but screening of ECs is inconsistent. The objective of this study was to determine the added value of screening both CRC and EC tumors in the same population. A prospective, immunohistochemistry (IHC)-based screening program for all patients with newly diagnosed CRCs and ECs was initiated in 2011 and 2013, respectively, at 2 centers (primary and tertiary). Genetic testing was recommended for those who had tumors with absent mutS homolog 2 (MSH2), MSH6, or postmeiotoic segregation increased 2 (PMS2) expression and for those who had tumors with absent mutL homolog 1 (MLH1) expression and no v-Raf murine sarcoma viral oncogene homolog B (BRAF) mutation or MLH1 promoter methylation. Amsterdam II criteria, revised Bethesda criteria, and scores from prediction models for gene mutations (the PREMM 1,2,6 and PREMM 5 prediction models) were ascertained in patients with LS. In total, 1290 patients with CRC and 484 with EC were screened for LS, and genetic testing was recommended for 137 patients (10.6%) and 32 patients (6.6%), respectively (P = .01). LS was identified in 16 patients (1.2%) with CRC and in 8 patients (1.7%) with EC. Among patients for whom genetic testing was recommended, the LS diagnosis rate was higher among those with EC (25.0% vs 11.7%, P = .052). The Amsterdam II criteria, revised Bethesda criteria, and both PREMM calculators would have missed 62.5%, 50.0%, and 12.5% of the identified patients with LS, respectively. Expanding a universal screening program for LS to include patients who had EC identified 50% more patients with LS, and many of these patients would have been missed by risk assessment tools (including PREMM 5 ). Universal screening programs for LS should include both CRC and EC. Cancer 2018. © 2018 American Cancer Society. © 2018 American Cancer Society.
Recombinant plasmids for encoding restriction enzymes DpnI and DpnII of streptococcus pneumontae
Lacks, Sanford A.
1990-01-01
Chromosomal DNA cassettes containing genes encoding either the DpnI or DpnII restriction endonucleases from Streptococcus pneumoniae are cloned into a streptococcal vector, pLS101. Large amounts of the restriction enzymes are produced by cells containing the multicopy plasmids, pLS202 and pLS207, and their derivatives pLS201, pLS211, pLS217, pLS251 and pLS252.
Recombinant plasmids for encoding restriction enzymes DpnI and DpnII of Streptococcus pneumontae
Lacks, S.A.
1990-10-02
Chromosomal DNA cassettes containing genes encoding either the DpnI or DpnII restriction endonucleases from Streptococcus pneumoniae are cloned into a streptococcal vector, pLS101. Large amounts of the restriction enzymes are produced by cells containing the multicopy plasmids, pLS202 and pLS207, and their derivatives pLS201, pLS211, pLS217, pLS251 and pLS252. 9 figs.
Wang, Shigang; Chin, Brian J; Gentile, Frank; Kunselman, Allen R; Palanzo, David; Ündar, Akif
2016-01-01
The objectives of this study were to investigate the relationship between revolution speed of a conventional centrifugal pump and negative pressure at the inlet of the pump by clamping the tubing upstream of the pump, and to verify whether negative pressure leads to gaseous microemboli (GME) production in a simulated adult extracorporeal life support (ECLS) system. The experimental circuit, including a Maquet Rotaflow centrifugal pump and a Medos Hilite 7000 LT polymethyl-pentene membrane oxygenator, was primed with packed red blood cells (hematocrit 35%). Negative pressure was created in the circuit by clamping the tubing upstream of the pump for 10 s, and then releasing the clamp. An emboli detection and classification quantifier was used to record GME volume and count at pre-oxygenator and post-oxygenator sites, and pressure and flow rate data were collected using a custom-based data acquisition system. All trials were conducted at 36°C at revolution speeds of 2000-4000 rpm (500 rpm increment). The flow rates were 1092.5-4708.4 mL/min at the revolution speeds of 2000-4000 rpm. Higher revolution speed generated higher negative pressure at the pre-pump site when clamping the tubing upstream of the pump (-108.3 ± 0.1 to -462.0 ± 0.5 mm Hg at 2000-4000 rpm). Moreover, higher negative pressure was associated with a larger number and volume of GME at pre-oxygenator site after de-clamp (GME count 10,573 ± 271 at pre-oxygenator site at 4000 rpm). The results showed that there was a potential danger of delivering GME to the patient when clamping pre-pump tubing during ECLS using a centrifugal pump. Our results warrant further clinical studies to investigate this phenomenon. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Zhao, Shanyu; Jiang, Bo; Maeder, Thomas; Muralt, Paul; Kim, Nayoung; Matam, Santhosh Kumar; Jeong, Eunho; Han, Yen-Lin; Koebel, Matthias M
2015-08-26
With growing public interest in portable electronics such as micro fuel cells, micro gas total analysis systems, and portable medical devices, the need for miniaturized air pumps with minimal electrical power consumption is on the rise. Thus, the development and downsizing of next-generation thermal transpiration gas pumps has been investigated intensively during the last decades. Such a system relies on a mesoporous membrane that generates a thermomolecular pressure gradient under the action of an applied temperature bias. However, the development of highly miniaturized active membrane materials with tailored porosity and optimized pumping performance remains a major challenge. Here we report a systematic study on the manufacturing of aerogel membranes using an optimized, minimal-shrinkage sol-gel process, leading to low thermal conductivity and high air conductance. This combination of properties results in superior performance for miniaturized thermomolecular air pump applications. The engineering of such aerogel membranes, which implies pore structure control and chemical surface modification, requires both chemical processing know-how and a detailed understanding of the influence of the material properties on the spatial flow rate density. Optimal pumping performance was found for devices with integrated membranes with a density of 0.062 g cm(-3) and an average pore size of 142.0 nm. Benchmarking of such low-density hydrophobic active aerogel membranes gave an air flow rate density of 3.85 sccm·cm(-2) at an operating temperature of 400 °C. Such a silica aerogel membrane based system has shown more than 50% higher pumping performance when compared to conventional transpiration pump membrane materials as well as the ability to withstand higher operating temperatures (up to 440 °C). This study highlights new perspectives for the development of miniaturized thermal transpiration air pumps while offering insights into the fundamentals of molecular pumping in three-dimensional open-mesoporous materials.
Borràs, Ester; Pineda, Marta; Cadiñanos, Juan; Del Valle, Jesús; Brieger, Angela; Hinrichsen, Inga; Cabanillas, Ruben; Navarro, Matilde; Brunet, Joan; Sanjuan, Xavier; Musulen, Eva; van der Klift, Helen; Lázaro, Conxi; Plotz, Guido; Blanco, Ignacio; Capellá, Gabriel
2013-08-01
The majority of mismatch repair (MMR) gene mutations causing Lynch syndrome (LS) occur either in MLH1 or MSH2. However, the relative contribution of PMS2 is less well defined. The aim of this study was to evaluate the role of PMS2 in LS by assessing the pathogenicity of variants of unknown significance (VUS) detected in the mutational analysis of PMS2 in a series of Spanish patients. From a cohort of 202 LS suspected patients, 13 patients showing loss of PMS2 expression in tumours were screened for germline mutations in PMS2, using a long range PCR based strategy and multiplex ligation dependent probe amplification (MLPA). Pathogenicity assessment of PMS2 VUS was performed evaluating clinicopathological data, frequency in control population and in silico and in vitro analyses at the RNA and protein level. Overall 25 different PMS2 DNA variants were detected. Fourteen were classified as polymorphisms. Nine variants were classified as pathogenic: seven alterations based on their molecular nature and two after demonstrating a functional defect (c.538-3C>G affected mRNA processing and c.137G>T impaired MMR activity). The c.1569C>G variant was classified as likely neutral while the c.384G>A remained as a VUS. We have also shown that the polymorphic variant c.59G>A is MMR proficient. Pathogenic PMS2 mutations were detected in 69% of patients harbouring LS associated tumours with loss of PMS2 expression. In all, PMS2 mutations account for 6% of the LS cases identified. The comprehensive functional analysis shown here has been useful in the classification of PMS2 VUS and contributes to refining the role of PMS2 in LS.
Kopylov, Uri; Klang, Eyal; Yablecovitch, Doron; Lahat, Adi; Avidan, Benjamin; Neuman, Sandra; Levhar, Nina; Greener, Tomer; Rozendorn, Noa; Beytelman, Arkadi; Yanai, Henit; Dotan, Iris; Chowers, Yehuda; Weiss, Batya; Ben-Horin, Shomron; Amitai, Marianne M.; Eliakim, Rami
2016-01-01
Background: Video capsule endoscopy (VCE) and magnetic resonance enterography (MRE) are the prime modalities for the evaluation of small bowel (SB) Crohn’s disease (CD). Mucosal inflammation on VCE is quantified using the Lewis score (LS). Diffusion-weighted (DW) magnetic resonance imaging (MRI) allows for accurate assessment of SB inflammation without administration of intravenous contrast material. The Magnetic Resonance Index of Activity (MaRiA) and the Clermont index are quantitative activity indices validated for contrast-enhanced MRE and DW-MRE, respectively. The aim of this study was to compare the quantification of distal SB inflammation by VCE and MR-related activity indices. Methods: Patients with known quiescent SB CD were prospectively recruited and underwent MRE and VCE. LS, MaRIA and Clermont scores were calculated for the distal SB. Results: Both MRI-based indices significantly correlated with the LS and the Clermont index (r = 0.50, p = 0.001 and r = 0.53, p = 0.001, respectively). Both MaRIA and Clermont scores were significantly lower in patients with mucosal healing (LS < 135). The area under the curve (AUC) with both MR scores was moderate for prediction of any mucosal inflammation (LS ⩾ 135) and excellent for prediction of moderate-to-severe inflammation (LS ⩾ 790) (0.71 and 0.74 versus 0.93 and 0.91 for MaRIA and Clermont score, respectively). Conclusions: Modest correlation between VCE- and MRE-based quantitative indices of inflammation in patients with quiescent SB CD was observed. Between-modality correlation was higher in patients with endoscopically severe disease. DW-MRE gauged by Clermont score was at least as accurate as contrast-enhanced MRE for quantification of SB inflammation. PMID:27582877
"Traditional" approaches to sampling groundwater and interpreting monitoring well data often provide misleading pictures of plume shape and location in the subsurface and the true extent of contamination. Groundwater samples acquired using pumps and bailers in conventional monito...
NASA Astrophysics Data System (ADS)
Wu, Jiagang; Xiao, Dingquan; Wang, Yuanyu; Zhu, Jianguo; Yu, Ping; Jiang, Yihang
2007-12-01
(1-x)(K0.42Na0.58)NbO3-xLiSbO3 [(1-x)KNN-xLS] lead-free piezoelectric ceramics were prepared by the conventional mixed oxide method. The compositional dependence of the phase structure and the electrical properties of the ceramics were studied. A morphotropic phase boundary (MPB) between the orthorhombic and tetragonal phases was identified in the composition range of 0.04
Fan, Shu-Xiang; Huang, Wen-Qian; Li, Jiang-Bo; Guo, Zhi-Ming; Zhaq, Chun-Jiang
2014-10-01
In order to detect the soluble solids content(SSC)of apple conveniently and rapidly, a ring fiber probe and a portable spectrometer were applied to obtain the spectroscopy of apple. Different wavelength variable selection methods, including unin- formative variable elimination (UVE), competitive adaptive reweighted sampling (CARS) and genetic algorithm (GA) were pro- posed to select effective wavelength variables of the NIR spectroscopy of the SSC in apple based on PLS. The back interval LS- SVM (BiLS-SVM) and GA were used to select effective wavelength variables based on LS-SVM. Selected wavelength variables and full wavelength range were set as input variables of PLS model and LS-SVM model, respectively. The results indicated that PLS model built using GA-CARS on 50 characteristic variables selected from full-spectrum which had 1512 wavelengths achieved the optimal performance. The correlation coefficient (Rp) and root mean square error of prediction (RMSEP) for prediction sets were 0.962, 0.403°Brix respectively for SSC. The proposed method of GA-CARS could effectively simplify the portable detection model of SSC in apple based on near infrared spectroscopy and enhance the predictive precision. The study can provide a reference for the development of portable apple soluble solids content spectrometer.
Kim, Beom Kyung; Kim, Seung Up; Choi, Gi Hong; Han, Woong Kyu; Park, Mi Sung; Kim, Eun Hye; Park, Jun Yong; Kim, Do Young; Choi, Jin Sub; Yang, Seung Choul; Choi, Eun Hee; Song, Kijun; Ahn, Sang Hoon; Han, Kwang-Hyub; Chon, Chae Yoon
2012-04-01
Liver stiffness (LS) measurement can distinguish individuals with potential liver disease (LD) from the general population. However, if LS is sex-sensitive, prevalence of LD may be incorrectly estimated when the same reference LS value is applied irrespective of sex. Here, we evaluated whether normal ranges of LS differ between healthy men and women. LS was measured in a cohort of healthy living liver and kidney donors, none of whom suffered from diabetes mellitus, hypertension, hepatitis B or C virus infection, heart or liver dysfunction, or metabolic syndrome. Patients with abnormal laboratory findings related to potential LD (platelet count < 150 × 10(3) /µL; aspartate aminotransferase > 40 IU/L; alanine aminotransferase [ALT] > 40 IU/L; albumin < 3.3 g/dL; total bilirubin > 1.2 mg/dL; gamma-glutamyl transpeptidase > 54 IU/L; alkaline phosphatase > 115 IU/L) were excluded. Among 242 patients analyzed, the mean age was 34.1 for men (n = 121) and 40.5 years for women (n = 121) (P < 0.001). Men had a higher mean LS value than women (5.2 ± 1.2 vs 4.8 ± 1.1 kPa/P < 0.001). Multivariate-linear regression analysis identified sex as the only independent factor for LS values (β = 0.361/P = 0.021). Using the 5th-95th percentiles, we determined normal LS ranges of 3.7-7.0 kPa in men and 3.3-6.8 kPa in women. In subgroups with ALT < 30 IU/L (subgroup-1, n = 216) and ALT < 20 IU/L (subgroup-2, n = 163), men had significantly higher LS values than women (5.2 ± 1.3 vs 4.7 ± 1.1 kPa/P = 0.003 and 5.1 ± 1.2 vs 4.7 ± 1.1 kPa/P = 0.030, respectively), demonstrating an independent sex effect (β = 0.483/P = 0.003 and β = 0.389/P = 0.030, respectively). An independent sex effect on LS values was confirmed. Thus, sex-specific references should be used for effective screening based on LS measurements. © 2011 Journal of Gastroenterology and Hepatology Foundation and Blackwell Publishing Asia Pty Ltd.
Researchers Apply Lesson Study: A Cycle of Lesson Planning, Implementation, and Revision
ERIC Educational Resources Information Center
Regan, Kelley S.; Evmenova, Anya S.; Kurz, Leigh Ann; Hughes, Melissa D.; Sacco, Donna; Ahn, Soo Y.; MacVittie, Nichole; Good, Kevin; Boykin, Andrea; Schwartzer, Jessica; Chirinos, David S.
2016-01-01
Scripted lesson plans and/or professional development alone may not be sufficient to encourage teachers to reflect on the quality of their teaching and improve their teaching. One learning tool that teachers may use to improve their teaching is Lesson Study (LS). LS is a collaborative process involving educators, based on concepts of iteration and…
Using Learning Study to Understand Preschoolers' Learning: Challenges and Possibilities
ERIC Educational Resources Information Center
Ljung-Djarf, Agneta; Olander, Mona Holmqvist
2013-01-01
This article reports a meta-analysis based on a multiple case study of the use of learning study (LS) to understand children's learning in Swedish preschool. The aim is to investigate whether and how the LS model can be developed, adjusted and used to meet contemporary demands placed upon preschool teachers for increased content focus and improved…
Setsompop, Kawin; Alagappan, Vijayanand; Gagoski, Borjan; Witzel, Thomas; Polimeni, Jonathan; Potthast, Andreas; Hebrank, Franz; Fontius, Ulrich; Schmitt, Franz; Wald, Lawrence L; Adalsteinsson, Elfar
2008-12-01
Slice-selective RF waveforms that mitigate severe B1+ inhomogeneity at 7 Tesla using parallel excitation were designed and validated in a water phantom and human studies on six subjects using a 16-element degenerate stripline array coil driven with a butler matrix to utilize the eight most favorable birdcage modes. The parallel RF waveform design applied magnitude least-squares (MLS) criteria with an optimized k-space excitation trajectory to significantly improve profile uniformity compared to conventional least-squares (LS) designs. Parallel excitation RF pulses designed to excite a uniform in-plane flip angle (FA) with slice selection in the z-direction were demonstrated and compared with conventional sinc-pulse excitation and RF shimming. In all cases, the parallel RF excitation significantly mitigated the effects of inhomogeneous B1+ on the excitation FA. The optimized parallel RF pulses for human B1+ mitigation were only 67% longer than a conventional sinc-based excitation, but significantly outperformed RF shimming. For example the standard deviations (SDs) of the in-plane FA (averaged over six human studies) were 16.7% for conventional sinc excitation, 13.3% for RF shimming, and 7.6% for parallel excitation. This work demonstrates that excitations with parallel RF systems can provide slice selection with spatially uniform FAs at high field strengths with only a small pulse-duration penalty. (c) 2008 Wiley-Liss, Inc.
Robust fitting for neuroreceptor mapping.
Chang, Chung; Ogden, R Todd
2009-03-15
Among many other uses, positron emission tomography (PET) can be used in studies to estimate the density of a neuroreceptor at each location throughout the brain by measuring the concentration of a radiotracer over time and modeling its kinetics. There are a variety of kinetic models in common usage and these typically rely on nonlinear least-squares (LS) algorithms for parameter estimation. However, PET data often contain artifacts (such as uncorrected head motion) and so the assumptions on which the LS methods are based may be violated. Quantile regression (QR) provides a robust alternative to LS methods and has been used successfully in many applications. We consider fitting various kinetic models to PET data using QR and study the relative performance of the methods via simulation. A data adaptive method for choosing between LS and QR is proposed and the performance of this method is also studied.
Shahlaei, Mohsen; Sabet, Razieh; Ziari, Maryam Bahman; Moeinifard, Behzad; Fassihi, Afshin; Karbakhsh, Reza
2010-10-01
Quantitative relationships between molecular structure and methionine aminopeptidase-2 inhibitory activity of a series of cytotoxic anthranilic acid sulfonamide derivatives were discovered. We have demonstrated the detailed application of two efficient nonlinear methods for evaluation of quantitative structure-activity relationships of the studied compounds. Components produced by principal component analysis as input of developed nonlinear models were used. The performance of the developed models namely PC-GRNN and PC-LS-SVM were tested by several validation methods. The resulted PC-LS-SVM model had a high statistical quality (R(2)=0.91 and R(CV)(2)=0.81) for predicting the cytotoxic activity of the compounds. Comparison between predictability of PC-GRNN and PC-LS-SVM indicates that later method has higher ability to predict the activity of the studied molecules. Copyright (c) 2010 Elsevier Masson SAS. All rights reserved.
He, Xianmin; Wei, Qing; Sun, Meiqian; Fu, Xuping; Fan, Sichang; Li, Yao
2006-05-01
Biological techniques such as Array-Comparative genomic hybridization (CGH), fluorescent in situ hybridization (FISH) and affymetrix single nucleotide pleomorphism (SNP) array have been used to detect cytogenetic aberrations. However, on genomic scale, these techniques are labor intensive and time consuming. Comparative genomic microarray analysis (CGMA) has been used to identify cytogenetic changes in hepatocellular carcinoma (HCC) using gene expression microarray data. However, CGMA algorithm can not give precise localization of aberrations, fails to identify small cytogenetic changes, and exhibits false negatives and positives. Locally un-weighted smoothing cytogenetic aberrations prediction (LS-CAP) based on local smoothing and binomial distribution can be expected to address these problems. LS-CAP algorithm was built and used on HCC microarray profiles. Eighteen cytogenetic abnormalities were identified, among them 5 were reported previously, and 12 were proven by CGH studies. LS-CAP effectively reduced the false negatives and positives, and precisely located small fragments with cytogenetic aberrations.
Beyhoff, Niklas; Brix, Sarah; Betz, Iris R; Klopfleisch, Robert; Foryst-Ludwig, Anna; Krannich, Alexander; Stawowy, Philipp; Knebel, Fabian; Grune, Jana; Kintscher, Ulrich
2017-12-01
The subendocardium is highly vulnerable to damage and is thus affected even in subclinical disease stages. Therefore, methods reflecting subendocardial status are of great clinical relevance for the early detection of cardiac damage and the prevention of functional impairment. The aim of this study was to investigate the potential ability of myocardial strain parameters to evaluate changes within the subendocardium. Male 129/Sv mice were injected with isoproterenol (ISO; n = 32) to induce isolated subendocardial fibrotic lesions or saline as appropriate control (n = 15). Transthoracic echocardiography was performed using a 30-MHz linear-frequency transducer coupled to a high-resolution imaging system, and acquired images were analyzed for conventional and strain parameters. The degree of collagen content within the different cardiac layers was quantified by histologic analysis and serum levels of tissue inhibitor of metalloproteinase-1, a biomarker for fibrosis, were assessed. ISO treatment induced a marked increase in subendocardial collagen content in response to cell loss (control vs ISO, 0.6 ± 0.3% vs 5.8 ± 0.9%; P < .001) and resulted in a moderate increase in left ventricular wall thickness with preserved systolic function. Global longitudinal peak strain (LS) and longitudinal strain rate were significantly decreased in ISO-treated animals (LS, -15.49% vs -11.49% [P = .001]; longitudinal strain rate, -4.81 vs -3.88 sec -1 [P < .05]), whereas radial and circumferential strain values remained unchanged. Global LS was associated with subendocardial collagen content (r = 0.46, P = .01) and tissue inhibitor of metalloproteinase-1 serum level (r = 0.52, P < .05). Further statistical analyses identified global LS as a superior predictor for the presence of subendocardial fibrosis (sensitivity, 84%; specificity, 80%; cutoff value, -14.4%). Assessment of LS may provide a noninvasive method for the detection of subendocardial damage and may consequently improve early diagnosis of cardiac diseases. Copyright © 2017 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
Heat Pump Drying of Fruits and Vegetables: Principles and Potentials for Sub-Saharan Africa
Fayose, Folasayo; Huan, Zhongjie
2016-01-01
Heat pump technology has been used for heating, ventilation, and air-conditioning in domestic and industrial sectors in most developed countries of the world including South Africa. However, heat pump drying (HPD) of fruits and vegetables has been largely unexploited in South Africa and by extension to the sub-Saharan African region. Although studies on heat pump drying started in South Africa several years ago, not much progress has been recorded to date. Many potential users view heat pump drying technology as fragile, slow, and high capital intensive when compared with conventional dryer. This paper tried to divulge the principles and potentials of heat pump drying technology and the conditions for its optimum use. Also, various methods of quantifying performances during heat pump drying as well as the quality of the dried products are highlighted. Necessary factors for maximizing the capacity and efficiency of a heat pump dryer were identified. Finally, the erroneous view that heat pump drying is not feasible economically in sub-Saharan Africa was clarified. PMID:26904668
A simple tagging system for protein encapsulation.
Seebeck, Florian P; Woycechowsky, Kenneth J; Zhuang, Wei; Rabe, Jürgen P; Hilvert, Donald
2006-04-12
Molecular containers that encapsulate specific cargo can be useful for many natural and non-natural processes. We report a simple system, based on charge complementarity, for the encapsulation of appropriately tagged proteins within an engineered, proteinaceous capsid. Four negative charges per monomer were added to the lumazine synthase from Aquifex aeolicus (AaLS). The capsids formed by the engineered AaLS associate with green fluorescent protein bearing a positively charged deca-arginine tag upon coproduction in Escherichia coli. Analytical ultracentrifugation and scanning force microscopy studies indicated that the engineered AaLS retains the ability to form capsids, but that their average size was substantially increased. The success of this strategy demonstrates that both the container and guest components of protein-based encapsulation systems can be convergently designed in a straightforward manner, which may help to extend their versatility.
Aqueous Humor Dynamics of the Brown-Norway Rat
Ficarrotta, Kayla R.; Bello, Simon A.; Mohamed, Youssef H.; Passaglia, Christopher L.
2018-01-01
Purpose The study aimed to provide a quantitative description of aqueous humor dynamics in healthy rat eyes. Methods One eye of 26 anesthetized adult Brown-Norway rats was cannulated with a needle connected to a perfusion pump and pressure transducer. Pressure-flow data were measured in live and dead eyes by varying pump rate (constant-flow technique) or by modulating pump duty cycle to hold intraocular pressure (IOP) at set levels (modified constant-pressure technique). Data were fit by the Goldmann equation to estimate conventional outflow facility (\\begin{document}\
Spacecraft radiators for advanced mission requirements
NASA Technical Reports Server (NTRS)
Leach, J. W.
1980-01-01
Design requirements for spacecraft heat rejection systems are identified, and their impact on the construction of conventional pumped fluid and hybrid heat pipe/pumped fluid radiators is evaluated. Heat rejection systems to improve the performance or reduce the cost of the spacecraft are proposed. Heat rejection requirements which are large compared to those of existing systems and mission durations which are relatively long, are discussed.
NASA Astrophysics Data System (ADS)
Abbatiello, L. A.; Nephew, E. A.; Ballou, M. L.
1981-03-01
The efficiency and life cycle costs of the brine chiller minimal annual cycle energy system (ACES) for residential space heating, air conditioning, and water heating requirements are compared with three conventional systems. The conventional systems evaluated are a high performance air-to-air heat pump with an electric resistance water heater, an electric furnace with a central air conditioner and an electric resistance water heater, and a high performance air-to-air heat pump with a superheater unit for hot water production. Monthly energy requirements for a reference single family house are calculated, and the initial cost and annual energy consumption of the systems, providing identical energy services, are computed and compared. The ACES consumes one third to one half ot the electrical energy required by the conventional systems and delivers the same annual loads at comparable costs.
2009-10-01
DARPA) Legged Squad Support System (LS3) Program. DARPA’s LS3 Program is an effort to develop a walking platform, preferably a quadruped, which...top-scoring UGV’s are track- or wheel-based; only the BigDog is a leg -based system. This presented BigDog with certain advantages (particularly...Technologies, Inc.’s ( DTI ) first location in Ranlo, North Carolina) – is a system capable of wheeled or tracked locomotion and was recently
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Qian; University of the Chinese Academy of Sciences, Beijing 100039; Li, Bincheng, E-mail: bcli@uestc.ac.cn
2015-12-07
In this paper, photocarrier radiometry (PCR) technique with multiple pump beam sizes is employed to determine simultaneously the electronic transport parameters (the carrier lifetime, the carrier diffusion coefficient, and the front surface recombination velocity) of silicon wafers. By employing the multiple pump beam sizes, the influence of instrumental frequency response on the multi-parameter estimation is totally eliminated. A nonlinear PCR model is developed to interpret the PCR signal. Theoretical simulations are performed to investigate the uncertainties of the estimated parameter values by investigating the dependence of a mean square variance on the corresponding transport parameters and compared to that obtainedmore » by the conventional frequency-scan method, in which only the frequency dependences of the PCR amplitude and phase are recorded at single pump beam size. Simulation results show that the proposed multiple-pump-beam-size method can improve significantly the accuracy of the determination of the electronic transport parameters. Comparative experiments with a p-type silicon wafer with resistivity 0.1–0.2 Ω·cm are performed, and the electronic transport properties are determined simultaneously. The estimated uncertainties of the carrier lifetime, diffusion coefficient, and front surface recombination velocity are approximately ±10.7%, ±8.6%, and ±35.4% by the proposed multiple-pump-beam-size method, which is much improved than ±15.9%, ±29.1%, and >±50% by the conventional frequency-scan method. The transport parameters determined by the proposed multiple-pump-beam-size PCR method are in good agreement with that obtained by a steady-state PCR imaging technique.« less
1981-09-30
will be required to de - liver the 651 gpm (41 l/s) needed for peak water use at the LSC. The existing Air Force test well at 3S-64E-12ca has been pumped...Valley is probably over 10,000 feet (3048 m) thick in the central part of the valley and is composed of alluvial fan, fluvial, playa , srl lacustrine...VALLEY T3.NSmIP STATION T EP SP. or SS. SILICA C AL C IU4 ACG. E5SILJ4 SCDIU I QANSA-SECT 5 6 C1 Ŕ VQ %;,. DES C CONE PH SOLIDS (5102) CA V$ A% 1 IN/6
A regional comparison of solar, heat pump, and solar-heat pump systems
NASA Astrophysics Data System (ADS)
Manton, B. E.; Mitchell, J. W.
1982-08-01
A comparative study of the thermal and economic performance of the parallel and series solar heat pump systems, stand alone solar and stand alone heat pump systems for residential space and domestic hot water heating for the U.S. using FCHART 4.0 is presented. Results show that the parallel solar heat pump system yields the greatest energy savings in the south. Very low cost collectors (50-150 dollars/sq m) are required for a series solar heat pump system in order for it to compete economically with the better of the parallel or solar systems. Conventional oil or gas furnaces need to have a seasonal efficiency of at least 70-85% in order to save as much primary energy as the best primary system in the northeast. In addition, the implications of these results for current or proposed federal tax credit measures are discussed.
A versatile and reconfigurable setup for all-terahertz time-resolved pump-probe spectroscopy.
Elezzabi, A Y; Maraghechi, P
2012-05-01
A versatile optical setup for all-terahertz (THz) time resolved pump-probe spectroscopy was designed and tested. By utilizing a dual THz pulse generator emitter module, independent and synchronized THz radiation pump and probe pulses were produced, thus eliminating the need for THz beam splitters and the limitations associated with their implementation. The current THz setup allows for precise control of the electric fields splitting ratio between the THz radiation pump and probe pulses, as well as in-phase, out-of-phase, and polarization dependent pump-probe spectroscopy. Since the present THz pump-probe setup does not require specialized THz radiation optical components, such as phase shifters, polarization rotators, or wide bandwidth beam splitters, it can be easily implemented with minimal alterations to a conventional THz time domain spectroscopy system. The present setup is valuable for studying the time dynamics of THz coherent phenomena in solid-state, chemical, and biological systems.
Jeong, Jae Yoon; Sohn, Joo Hyun; Sohn, Won; Park, Chan Hyuk; Kim, Tae Yeob; Jun, Dae Won; Kim, Yongsoo; Jeong, Woo Kyoung
2017-01-01
Background/Aims To investigate the use of measurements of liver stiffness (LS) by two-dimensional real-time shear wave elastography (SWE) for predicting the development of hepatocellular carcinoma (HCC) in patients with chronic hepatitis B (CHB). Methods We retrospectively collected data on 291 enrolled patients with CHB whose LS had been measured using SWE. Results The mean age of the patients was 46.8 years; males predominated (67%), and 40 of the patients (14%) had clinical cirrhosis. Among the patients, 165 (56.7%) received antiviral treatment. The median LS value was 7.4 kPa, and the median follow-up period was 35.8 months (range, 3.0 to 52.8 months). During follow-up, HCC developed in 13 patients (4.5%), and the cumulative incidence rates of HCC at 1, 2, and 4 years were 1.1%, 3.6%, and 8.4%, respectively. Based on a multivariate analysis, older age (≥50 years) and higher LS value (≥10 kPa) were independently associated with the risk of developing HCC (hazard ratio [HR], 4.53, p=0.023; and HR, 4.08, p=0.022). The cumulative incidence rate of HCC was significantly higher in patients with higher LS values (≥10 kPa) than in those with lower LS values (<10 kPa) (p=0.001). Conclusions Increased LS measured by SWE at any time point regardless of antiviral treatment is associated with an increased risk of HCC in patients with CHB. PMID:28651307
Development of Consensus Treatment Plans for Juvenile Localized Scleroderma
Li, Suzanne C.; Torok, Kathryn S.; Pope, Elena; Dedeoglu, Fatma; Hong, Sandy; Jacobe, Heidi T.; Rabinovich, C. Egla; Laxer, Ronald M.; Higgins, Gloria C.; Ferguson, Polly J.; Lasky, Andrew; Baszis, Kevin; Becker, Mara; Campillo, Sarah; Cartwright, Victoria; Cidon, Michael; Inman, Christi J; Jerath, Rita; O'Neil, Kathleen M.; Vora, Sheetal; Zeft, Andrew; Wallace, Carol A.; Ilowite, Norman T.; Fuhlbrigge, Robert C
2013-01-01
Objective To develop standardized treatment plans, clinical assessments, and response criteria for active, moderate to high severity juvenile localized scleroderma (jLS). Background jLS is a chronic inflammatory skin disorder associated with substantial morbidity and disability. Although a wide range of therapeutic strategies have been reported in the literature, a lack of agreement on treatment specifics and accepted methods for clinical assessment of have made it difficult to compare approaches and identify optimal therapy. Methods A core group of pediatric rheumatologists, dermatologists and a lay advisor was engaged by the Childhood Arthritis and Rheumatology Research Alliance (CARRA) to develop standardized treatment plans and assessment parameters for jLS using consensus methods/nominal group techniques. Recommendations were validated in two face-to-face conferences with a larger group of practitioners with expertise in jLS and with the full membership of CARRA, which encompasses the majority of pediatric rheumatologists in the U.S and Canada. Results Consensus was achieved on standardized treatment plans that reflect the prevailing treatment practices of CARRA members. Standardized clinical assessment methods and provisional treatment response criteria were also developed. Greater than 90% of pediatric rheumatologists responding to a survey (67% of CARRA membership) affirmed the final recommendations and agreed to utilize these consensus plans to treat patients with jLS. Conclusions Using consensus methodology, we have developed standardized treatment plans and assessment methods for jLS. The high level of support among pediatric rheumatologists will support future comparative effectiveness studies and enable the development of evidence-based guidelines for the treatment of jLS. PMID:22505322
Few-mode fiber based Raman distributed temperature sensing.
Wang, Meng; Wu, Hao; Tang, Ming; Zhao, Zhiyong; Dang, Yunli; Zhao, Can; Liao, Ruolin; Chen, Wen; Fu, Songnian; Yang, Chen; Tong, Weijun; Shum, Perry Ping; Liu, Deming
2017-03-06
We proposed and experimentally demonstrated a few mode fiber (FMF) based Raman distributed temperature sensor (RDTS) to extend the sensing distance with enhanced signal-to-noise ratio (SNR) of backscattered anti-Stokes spontaneous Raman scattering. Operating in the quasi-single mode (QSM) with efficient fundamental mode excitement, the FMF allows much larger input pump power before the onset of stimulated Raman scattering compared with the standard single mode fiber (SSMF) and mitigates the detrimental differential mode group delay (DMGD) existing in the conventional multimode fiber (MMF) based RDTS system. Comprehensive theoretical analysis has been conducted to reveal the benefits of RDTS brought by QSM operated FMFs with the consideration of geometric/optical parameters of different FMFs. The measurement uncertainty of FMF based scheme has also been evaluated. Among fibers being investigated and compared (SSMF, 2-mode and 4-mode FMFs, respectively), although an ideal 4-mode FMF based RDTS has the largest SNR enhancement in principle, real fabrication imperfections and larger splicing loss degrade its performance. While the 2-mode FMF based system outperforms in longer distance measurement, which agrees well with the theoretical calculations considering real experimental parameters. Using the conventional RDTS hardware, a 30-ns single pulse at 1550nm has been injected as the pump; the obtained temperature resolutions at 20km distance are estimated to be about 10°C, 7°C and 6°C for the SSMF, 4-mode and 2-mode FMFs, respectively. About 4°C improvement over SSMF on temperature resolution at the fiber end with 3m spatial resolution within 80s measuring time over 20km 2-mode FMFs have been achieved.
Prototype of Self-Sensing Magnetic Bearing for Liquid Nitrogen Pump
NASA Astrophysics Data System (ADS)
Eguchi, Seiji; Komori, Mochimitsu; Okuhata, Taro
Recently, pumps used in extremely low temperature such as 77K are found to be necessary. They are expected to use for rocket engines and hydrogen stations for fueled vehicles. Generally, conventional magnetic bearings do not work in the extremely low temperature. Therefore, we have studied magnitic bearings for these pumps. Self-sensing technique is tried to apply to magnetic bearings. If self-sensing magnetic bearings were made, we could apply the self-sensing magnetic bearing to liquid nitrogen pumps. In this paper, we propose a prototype self-sensing magnetic bearing and study the static and dynamic characteristics. The dynamic characteristics in the air and in liquid nitrogen are also discussed.
Oral sustained-release suspension based on a lauryl sulfate salt/complex.
Kasashima, Yuuki; Uchida, Shinya; Yoshihara, Keiichi; Yasuji, Takehiko; Sako, Kazuhiro; Namiki, Noriyuki
2016-12-30
The objective of this study was to evaluate the feasibility of lauryl sulfate (LS) salt/complex as a novel carrier in oral sustained-release suspensions. Mirabegron, which has a pH-dependent solubility, was selected as the model drug. Sodium lauryl sulfate (SLS) was bound to mirabegron in a stoichiometric manner to form an LS salt/complex. LS salt/complex formulation significantly reduced the solubility of mirabegron and helped mirabegron achieve sustained-release over a wide range of pH conditions. Microparticles containing the LS salt/complex were prepared by spray drying with the aqueous dispersion of ethylcellulose (Aquacoat ® ECD). The diameter of the microparticles was less than 200μm, which will help avoid a gritty taste. In vitro results indicated the microparticles had slower dissolution profiles than the LS salt/complex. The dissolution rate could be controlled flexibly by changing the amount of Aquacoat ® ECD. The microparticle suspension retained the desired sustained-release property and dissolution profile after being stored for 30days at 40°C. In addition, the suspension displayed sustained-release behavior in dogs without a pronounced C max peak, which will help prevent side effects. These results suggest that microparticles containing LS salt/complex may be useful as a novel sustained-release suspension for oral delivery. Copyright © 2016 Elsevier B.V. All rights reserved.
Lee, Hyeran; Akers, Walter J; Cheney, Philip P; Edwards, W Barry; Liang, Kexian; Culver, Joseph P; Achilefu, Samuel
2009-01-01
Based on the capability of modulating fluorescence intensity by specific molecular events, we report a new multimodal optical-nuclear molecular probe with complementary reporting strategies. The molecular probe (LS498) consists of tetraazacyclododecanetetraacetic acid (DOTA) for chelating a radionuclide, a near-infrared fluorescent dye, and an efficient quencher dye. The two dyes are separated by a cleavable peptide substrate for caspase-3, a diagnostic enzyme that is upregulated in dying cells. LS498 is radiolabeled with (64)Cu, a radionuclide used in positron emission tomography. In the native form, LS498 fluorescence is quenched until caspase-3 cleavage of the peptide substrate. Enzyme kinetics assay shows that LS498 is readily cleaved by caspase-3, with excellent enzyme kinetic parameters k(cat) and K(M) of 0.55+/-0.01 s(-1) and 1.12+/-0.06 microM, respectively. In mice, the initial fluorescence of LS498 is ten-fold less than control. Using radiolabeled (64)Cu-LS498 in a controlled and localized in-vivo model of caspase-3 activation, a time-dependent five-fold NIR fluorescence enhancement is observed, but radioactivity remains identical in caspase-3 positive and negative controls. These results demonstrate the feasibility of using radionuclide imaging for localizing and quantifying the distribution of molecular probes and optical imaging for reporting the functional status of diagnostic enzymes.
NASA Astrophysics Data System (ADS)
Lee, Hyeran; Akers, Walter J.; Cheney, Philip P.; Edwards, W. Barry; Liang, Kexian; Culver, Joseph P.; Achilefu, Samuel
2009-07-01
Based on the capability of modulating fluorescence intensity by specific molecular events, we report a new multimodal optical-nuclear molecular probe with complementary reporting strategies. The molecular probe (LS498) consists of tetraazacyclododecanetetraacetic acid (DOTA) for chelating a radionuclide, a near-infrared fluorescent dye, and an efficient quencher dye. The two dyes are separated by a cleavable peptide substrate for caspase-3, a diagnostic enzyme that is upregulated in dying cells. LS498 is radiolabeled with 64Cu, a radionuclide used in positron emission tomography. In the native form, LS498 fluorescence is quenched until caspase-3 cleavage of the peptide substrate. Enzyme kinetics assay shows that LS498 is readily cleaved by caspase-3, with excellent enzyme kinetic parameters kcat and KM of 0.55+/-0.01 s-1 and 1.12+/-0.06 μM, respectively. In mice, the initial fluorescence of LS498 is ten-fold less than control. Using radiolabeled 64Cu-LS498 in a controlled and localized in-vivo model of caspase-3 activation, a time-dependent five-fold NIR fluorescence enhancement is observed, but radioactivity remains identical in caspase-3 positive and negative controls. These results demonstrate the feasibility of using radionuclide imaging for localizing and quantifying the distribution of molecular probes and optical imaging for reporting the functional status of diagnostic enzymes.
System Engineering Approach to Assessing Integrated Survivability
2009-08-01
based response for the above engagements using LS- Dyna for blast modelling, MADYMO for safety and human response, CFD software (Fluent) is used to...Simulation JFAS Joint Force Analysis Simulation JANUS Joint Army Navy Uniform Simulation LS- DYNA Livermore Software-Dynamics MADYMO...management technologies. The “don’t be killed” layer of survivability protection accounts for many of the mitigation technologies (i.e. blast
ERIC Educational Resources Information Center
Shen, Siu-Tsen
2016-01-01
This paper presents an ongoing study of the development of a customizable web browser information organization and management system, which the author has named Lexicon Sextant (LS). LS is a user friendly, graphical web based add-on to the latest generation of web browsers, such as Google Chrome, making it easier and more intuitive to store and…
Banerjee, Bhadrani; Tripathi, Anvita; Das, Adrija; Singh, Kumari Alka; Banerjee, J. P.
2015-01-01
The authors have carried out the large-signal (L-S) simulation of double-drift region (DDR) impact avalanche transit time (IMPATT) diodes based on 〈111〉, 〈100〉, and 〈110〉 oriented GaAs. A nonsinusoidal voltage excited (NSVE) L-S simulation technique is used to investigate both the static and L-S performance of the above-mentioned devices designed to operate at millimeter-wave (mm-wave) atmospheric window frequencies, such as 35, 94, 140, and 220 GHz. Results show that 〈111〉 oriented GaAs diodes are capable of delivering maximum RF power with highest DC to RF conversion efficiency up to 94 GHz; however, the L-S performance of 〈110〉 oriented GaAs diodes exceeds their other counterparts while the frequency of operation increases above 94 GHz. The results presented in this paper will be helpful for the future experimentalists to choose the GaAs substrate of appropriate orientation to fabricate DDR GaAs IMPATT diodes at mm-wave frequencies. PMID:27347524
Science and society: some "made-in-Canada" options for improving integration.
Kosseim, Patricia; Chapman, Sheila
2011-05-01
In this article, the authors describe relatively recent efforts by scientific research agencies to promote, through various funding programs, the integration of social sciences and humanities with the natural sciences. This "integrated" approach seeks to study science through a broader interdisciplinary lens in order to better anticipate, understand, and address its ethical, legal, and social implications. The authors review the origins and evolution of this trend, as well the arguments which have been formulated by both proponents and critics of integration. By using Genome Canada's "GE(3)LS" Research Program as a case study, the authors discuss the successes and continuing challenges of this model based on evaluation results available to date. The authors then go on to examine and compare three possible models for improving the future success of the GE(3)LS research program, including: 1) enhancing the current integrated research approach through incremental refinements based on concrete evidence and lessons learned; 2) promoting greater interaction and synergy across GE(3)LS research projects through a deliberate, systematic and coordinated "hub and spoke" approach; and 3) taking a broad programmatic approach to GE(3)LS research by creating a central resource of available expertise and advisory capacity.
Lichen sclerosis: clinicopathological study of 60 cases from Lebanon.
Knio, Zeina; Kurban, Mazen; Abbas, Ossama
2016-10-01
Lichen sclerosus (LS) is an uncommon idiopathic chronic inflammatory debilitating disease with predilection for the genital region. Our recent encounter with an LS case exhibiting perineural inflammation microscopically prompted us to assess the features of all patients diagnosed with LS at our institution. All cases of LS diagnosed between 1990 and 2014 were retrospectively reviewed. Diagnosis was confirmed with demonstration of microscopic features typical of LS. Sixty patients (42 women and 18 men) with 65 biopsy specimens of LS were identified, of which 41 were extragenital, 16 genital, and three had both. Histopathologically, significantly higher proportions of follicular plugging, atrophy, and vacuolar interface changes were observed in extragenital LS cases, while angiokeratoma-like, mycosis fungoides-like, and pseudoepitheliomatous changes were only seen in genital LS. Perineural inflammation was observed as a novel finding in 22 cases (33.8%) of LS. Features of patients with LS in this study are generally comparable to those published in the literature, with some differences. In contrast to the literature, extragenital LS was more frequently encountered. Histopathologically, perineural inflammation was not an uncommon feature of LS and thus may serve as a clue in the differentiation of LS from its mimickers. © 2016 The International Society of Dermatology.
Artificial groundwater recharge as integral part of a water resources system in a humid environment
NASA Astrophysics Data System (ADS)
Kupfersberger, Hans; Stadler, Hermann
2010-05-01
In Graz, Austria, artificial groundwater recharge has been operated as an integral part of the drinking water supply system for more than thirty years. About 180 l/s of high quality water from pristine creeks (i.e. no pre-treatment necessary) are infiltrated via sand and lawn basins and infiltration trenches into two phreatic aquifers to sustain the extraction of approximately 400 l/s. The remaining third of drinking water for roughly 300.000 people is provided by a remote supply line from the East alpine karst region Hochschwab. By this threefold model the water supply system is less vulnerable to external conditions. In the early 1980's the infiltration devices were also designed as a hydraulic barrier against riverbank infiltration from the river Mur, which at that time showed seriously impaired water quality due to upstream paper mills. This resulted into high iron and manganese groundwater concentrations which lead to clogging of the pumping wells. These problems have been eliminated in the meantime due to the onsite purification of paper mill effluents and the construction of many waste water treatment plants. The recharge system has recently been thoroughly examined to optimize the operation of groundwater recharge and to provide a basis for further extension. The investigations included (i) field experiments and laboratory analyses to improve the trade off between infiltration rate and elimination capacities of the sand filter basins' top layer, (ii) numerical groundwater modelling to compute the recovery rate of the recharged water, the composition of the origin of the pumped water, emergency scenarios due to the failure of system parts, the transient capture zones of the withdrawal wells and the coordination of recharge and withdrawal and (iii) development of an online monitoring setup combined with a decision support system to guarantee reliable functioning of the entire structure. Additionally, the depreciation, maintenance and operation costs of the managed aquifer recharge system have been evaluated. Among numerous results it could be shown that replacing the lawn by sand basins and operating them constantly during winter holds the largest potential to increase the infiltration volume. However, this is only an option for new to build structures since the current basin positions would lead to large direct losses of recharged groundwater into the river Mur. Adjusting the timing of infiltration and withdrawal based on subsurface travel time yields an increase of the pumped amount of about 11% given about the same extension the wells' capture zones. The overall costs of artificial groundwater recharge amount to 0,15 €/m³ excluding pumping and distribution costs compared to a water price of about 1,5 €/m³ charged to consumers. Currently, the implications of building a hydro power plant adjacent to the recharge site are evaluated emphasizing the need for innovative solutions given only limited land resources. On the basis of the projected impacts of climate change on the availability of surface water and groundwater in the South-Eastern alpine regions, the aquifers can act as a buffer system to help overcome the timely shift between supply and demand. Thus, also in predominantly humid regions artificial groundwater recharge represents a viable and sustainable solution to safeguard the supply of drinking water in the long term.
Turbopump options for nuclear thermal rockets
NASA Astrophysics Data System (ADS)
Bissell, W. R.; Gunn, S. V.
1992-07-01
Several turbopump options for delivering liquid nitrogen to nuclear thermal rocket (NTR) engines were evaluated and compared. Axial and centrifugal flow pumps were optimized, with and without boost pumps, utilizing current design criteria within the latest turbopump technology limits. Two possible NTR design points were used, a modest pump pressure rise of 1,743 psia and a relatively higher pump pressure rise of 4,480 psia. Both engines utilized the expander cycle to maximize engine performance for the long duration mission. Pump suction performance was evaluated. Turbopumps with conventional cavitating inducers were compared with zero NPSH (saturated liquid in the tanks) pumps over a range of tank saturation pressures, with and without boost pumps. Results indicate that zero NSPH pumps at high tank vapor pressures, 60 psia, are very similar to those with the finite NPSHs. At low vapor pressures efficiencies fall and turbine pressure ratios increase leading to decreased engine chamber pressures and or increased pump pressure discharges and attendant high-pressure component weights. It may be concluded that zero tank NSPH capabilities can be obtained with little penalty to the engine systems but boost pumps are needed if tank vapor pressure drops below 30 psia. Axial pumps have slight advantages in weight and chamber pressure capability while centrifugal pumps have a greater operating range.
Nishimura, K; Park, C H; Akamatsu, T; Yamada, T; Ban, T
1996-01-01
To overcome problems with the shaft seal in conventional centrifugal pumps, the authors have been developing a magnetically suspended centrifugal pump (MSCP) that operates as a valveless, sealless, and bearingless pump. The prototype of the MSCP was modified with respect to size of the volute diffuser and impeller blade profiles. A hemolysis test in vitro using a new version of the MSCP was performed in comparison with a commercially available centrifugal pump. The test circuit for the hemolysis test comprised a blood reservoir, a pump, and polyvinyl tubes, and was filled with fresh heparinized bovine blood. The pumping conditions were a flow rate of 5 L/min and a pump head afterload of 100 mmHg. The index of hemolysis in the MSCP was significantly lower than that in the Biomedicus pump (0.0035 +/- 0.0025 versus 0.0097 +/- 0.0056 g/100 L, p < 0.05). Reduction in the platelet count during pumping also was lower in the MSCP compared with the Biomedicus pump at both 6 hrs and 12 hrs of pumping (p < 0.01). This MSCP may be advantageous for extended use of assist devices, not only from the theoretical point of view, but in a practical sense after the results of the current hemolysis test.
Reliability Evaluation of Low Power Schottky Clamped Microcircuits.
1980-02-01
Temperature 52 15. 54LS191: ICC Versus Temperature 53 16. 54LS181: ICC Versus Temperature 54 17. High Temperature ...Response, Vendor A, 54LS181 56 18. High Temperature Response, Vendor B, 54LS181 57 19. High Temperature Response, Vendor A, 54LS191 58 20. High ... Temperature Response, Vendor B, 54LS191 59 21. High Temperature Response, Vendor A, 54LS251 60 3 LIST OF FIGURES (continued) Figure No. Title Page 22. High
LS-SNP: large-scale annotation of coding non-synonymous SNPs based on multiple information sources.
Karchin, Rachel; Diekhans, Mark; Kelly, Libusha; Thomas, Daryl J; Pieper, Ursula; Eswar, Narayanan; Haussler, David; Sali, Andrej
2005-06-15
The NCBI dbSNP database lists over 9 million single nucleotide polymorphisms (SNPs) in the human genome, but currently contains limited annotation information. SNPs that result in amino acid residue changes (nsSNPs) are of critical importance in variation between individuals, including disease and drug sensitivity. We have developed LS-SNP, a genomic scale software pipeline to annotate nsSNPs. LS-SNP comprehensively maps nsSNPs onto protein sequences, functional pathways and comparative protein structure models, and predicts positions where nsSNPs destabilize proteins, interfere with the formation of domain-domain interfaces, have an effect on protein-ligand binding or severely impact human health. It currently annotates 28,043 validated SNPs that produce amino acid residue substitutions in human proteins from the SwissProt/TrEMBL database. Annotations can be viewed via a web interface either in the context of a genomic region or by selecting sets of SNPs, genes, proteins or pathways. These results are useful for identifying candidate functional SNPs within a gene, haplotype or pathway and in probing molecular mechanisms responsible for functional impacts of nsSNPs. http://www.salilab.org/LS-SNP CONTACT: rachelk@salilab.org http://salilab.org/LS-SNP/supp-info.pdf.
Least-Squares Support Vector Machine Approach to Viral Replication Origin Prediction
Cruz-Cano, Raul; Chew, David S.H.; Kwok-Pui, Choi; Ming-Ying, Leung
2010-01-01
Replication of their DNA genomes is a central step in the reproduction of many viruses. Procedures to find replication origins, which are initiation sites of the DNA replication process, are therefore of great importance for controlling the growth and spread of such viruses. Existing computational methods for viral replication origin prediction have mostly been tested within the family of herpesviruses. This paper proposes a new approach by least-squares support vector machines (LS-SVMs) and tests its performance not only on the herpes family but also on a collection of caudoviruses coming from three viral families under the order of caudovirales. The LS-SVM approach provides sensitivities and positive predictive values superior or comparable to those given by the previous methods. When suitably combined with previous methods, the LS-SVM approach further improves the prediction accuracy for the herpesvirus replication origins. Furthermore, by recursive feature elimination, the LS-SVM has also helped find the most significant features of the data sets. The results suggest that the LS-SVMs will be a highly useful addition to the set of computational tools for viral replication origin prediction and illustrate the value of optimization-based computing techniques in biomedical applications. PMID:20729987
Least-Squares Support Vector Machine Approach to Viral Replication Origin Prediction.
Cruz-Cano, Raul; Chew, David S H; Kwok-Pui, Choi; Ming-Ying, Leung
2010-06-01
Replication of their DNA genomes is a central step in the reproduction of many viruses. Procedures to find replication origins, which are initiation sites of the DNA replication process, are therefore of great importance for controlling the growth and spread of such viruses. Existing computational methods for viral replication origin prediction have mostly been tested within the family of herpesviruses. This paper proposes a new approach by least-squares support vector machines (LS-SVMs) and tests its performance not only on the herpes family but also on a collection of caudoviruses coming from three viral families under the order of caudovirales. The LS-SVM approach provides sensitivities and positive predictive values superior or comparable to those given by the previous methods. When suitably combined with previous methods, the LS-SVM approach further improves the prediction accuracy for the herpesvirus replication origins. Furthermore, by recursive feature elimination, the LS-SVM has also helped find the most significant features of the data sets. The results suggest that the LS-SVMs will be a highly useful addition to the set of computational tools for viral replication origin prediction and illustrate the value of optimization-based computing techniques in biomedical applications.
NASA Astrophysics Data System (ADS)
Alesemi, Meshari
2018-04-01
The objective of this research is to illustrate the effectiveness of the thermal relaxation time based on the theory of Lord-Shulman (L-S), Coriolis and Centrifugal Forces on the reflection coefficients of plane waves in an anisotropic magneto-thermoelastic medium. Assuming the elastic medium is rotating with stable angular velocity and the imposed magnetic field is parallel to the boundary of the half-space. The basic equations of a transversely isotropic rotating magneto-thermoelastic medium are formulated according to thermoelasticity theory of Lord-Shulman (L-S). Next to that, getting the velocity equation which is illustrated to show existence of three quasi-plane waves propagating in the medium. The amplitude ratios coefficients of these plane waves have been given and then computed numerically and plotted graphically to demonstrate the influences of the rotation on the Zinc material.
NASA Astrophysics Data System (ADS)
Dabiri, Mohammad Taghi; Sadough, Seyed Mohammad Sajad
2018-04-01
In the free-space optical (FSO) links, atmospheric turbulence lead to scintillation in the received signal. Due to its ease of implementation, intensity modulation with direct detection (IM/DD) based on ON-OFF keying (OOK) is a popular signaling scheme in these systems. Over turbulence channel, to detect OOK symbols in a blind way, i.e., without sending pilot symbols, an expectation-maximization (EM)-based detection method was recently proposed in the literature related to free-space optical (FSO) communication. However, the performance of EM-based detection methods severely depends on the length of the observation interval (Ls). To choose the optimum values of Ls at target bit error rates (BER)s of FSO communications which are commonly lower than 10-9, Monte-Carlo simulations would be very cumbersome and require a very long processing time. To facilitate performance evaluation, in this letter we derive the analytic expressions for BER and outage probability. Numerical results validate the accuracy of our derived analytic expressions. Our results may serve to evaluate the optimum value for Ls without resorting to time-consuming Monte-Carlo simulations.
Jaitly, Navdeep; Mayampurath, Anoop; Littlefield, Kyle; Adkins, Joshua N; Anderson, Gordon A; Smith, Richard D
2009-01-01
Background Data generated from liquid chromatography coupled to high-resolution mass spectrometry (LC-MS)-based studies of a biological sample can contain large amounts of biologically significant information in the form of proteins, peptides, and metabolites. Interpreting this data involves inferring the masses and abundances of biomolecules injected into the instrument. Because of the inherent complexity of mass spectral patterns produced by these biomolecules, the analysis is significantly enhanced by using visualization capabilities to inspect and confirm results. In this paper we describe Decon2LS, an open-source software package for automated processing and visualization of high-resolution MS data. Drawing extensively on algorithms developed over the last ten years for ICR2LS, Decon2LS packages the algorithms as a rich set of modular, reusable processing classes for performing diverse functions such as reading raw data, routine peak finding, theoretical isotope distribution modelling, and deisotoping. Because the source code is openly available, these functionalities can now be used to build derivative applications in relatively fast manner. In addition, Decon2LS provides an extensive set of visualization tools, such as high performance chart controls. Results With a variety of options that include peak processing, deisotoping, isotope composition, etc, Decon2LS supports processing of multiple raw data formats. Deisotoping can be performed on an individual scan, an individual dataset, or on multiple datasets using batch processing. Other processing options include creating a two dimensional view of mass and liquid chromatography (LC) elution time features, generating spectrum files for tandem MS data, creating total intensity chromatograms, and visualizing theoretical peptide profiles. Application of Decon2LS to deisotope different datasets obtained across different instruments yielded a high number of features that can be used to identify and quantify peptides in the biological sample. Conclusion Decon2LS is an efficient software package for discovering and visualizing features in proteomics studies that require automated interpretation of mass spectra. Besides being easy to use, fast, and reliable, Decon2LS is also open-source, which allows developers in the proteomics and bioinformatics communities to reuse and refine the algorithms to meet individual needs. Decon2LS source code, installer, and tutorials may be downloaded free of charge at . PMID:19292916
Jaitly, Navdeep; Mayampurath, Anoop; Littlefield, Kyle; Adkins, Joshua N; Anderson, Gordon A; Smith, Richard D
2009-03-17
Data generated from liquid chromatography coupled to high-resolution mass spectrometry (LC-MS)-based studies of a biological sample can contain large amounts of biologically significant information in the form of proteins, peptides, and metabolites. Interpreting this data involves inferring the masses and abundances of biomolecules injected into the instrument. Because of the inherent complexity of mass spectral patterns produced by these biomolecules, the analysis is significantly enhanced by using visualization capabilities to inspect and confirm results. In this paper we describe Decon2LS, an open-source software package for automated processing and visualization of high-resolution MS data. Drawing extensively on algorithms developed over the last ten years for ICR2LS, Decon2LS packages the algorithms as a rich set of modular, reusable processing classes for performing diverse functions such as reading raw data, routine peak finding, theoretical isotope distribution modelling, and deisotoping. Because the source code is openly available, these functionalities can now be used to build derivative applications in relatively fast manner. In addition, Decon2LS provides an extensive set of visualization tools, such as high performance chart controls. With a variety of options that include peak processing, deisotoping, isotope composition, etc, Decon2LS supports processing of multiple raw data formats. Deisotoping can be performed on an individual scan, an individual dataset, or on multiple datasets using batch processing. Other processing options include creating a two dimensional view of mass and liquid chromatography (LC) elution time features, generating spectrum files for tandem MS data, creating total intensity chromatograms, and visualizing theoretical peptide profiles. Application of Decon2LS to deisotope different datasets obtained across different instruments yielded a high number of features that can be used to identify and quantify peptides in the biological sample. Decon2LS is an efficient software package for discovering and visualizing features in proteomics studies that require automated interpretation of mass spectra. Besides being easy to use, fast, and reliable, Decon2LS is also open-source, which allows developers in the proteomics and bioinformatics communities to reuse and refine the algorithms to meet individual needs.Decon2LS source code, installer, and tutorials may be downloaded free of charge at http://http:/ncrr.pnl.gov/software/.
Xu, Jianguo; Zheng, Tingting; Le, Jingqing; Jia, Lee
2017-11-20
Occurrence and application of oligonucleotide probes have promoted great progress in the biochemical analysis field due to their unique biological and chemical properties. In this work, a long-stem shaped multifunctional molecular beacon (LS-MMB) that is responsive to a cancer-related gene, p53, is well-prepared. By designing the probe with long-paired bases at its two ends and short-paired bases between the middle region and the 3' end, the LS-MMB is intelligently endowed with the ability to recognize the target analyte, serve as the polymerization primer/template, and signal the hybridization event synchronously, which is distinctly advantageous over the traditional molecular beacons (MBs). Moreover, it is excitingly found that the LS-MMB can be employed to exert intramolecular and intermolecular interactions for strand displacement amplification (SDA) without the involvement of any assistant probes; this therapy results in a really easy and rapid sensing system that provides an extremely low background noise and high target output signal. In this case, an excellent sensitivity and specificity to detect target gene down to picomolar level and resolution to even one nucleotide variation are achieved, respectively. In addition, the application potential for real genomic DNA analysis is realized. We envision that the probe of LS-MMB can act as a universal platform for biosensing and biomedical research.
Hieftje, Kimberly D; Pendergrass, Tyra M; Kyriakides, Tassos C; Duncan, Lindsay R; Dziura, James D; Sawyer, Benjamin G; Mayes, Linda; Crusto, Cindy A; Forsyth, Brian WC; Fiellin, David A
2017-01-01
Background Human immunodeficiency virus (HIV) disproportionately impacts minority youth. Interventions to decrease HIV sexual risk are needed. Objective We hypothesized that an engaging theory-based digital health intervention in the form of an interactive video game would improve sexual health outcomes in adolescents. Methods Participants aged 11 to 14 years from 12 community afterschool, school, and summer programs were randomized 1:1 to play up to 16 hours of an experimental video game or control video games over 6 weeks. Assessments were conducted at 6 weeks and at 3, 6, and 12 months. Primary outcome was delay of initiation of vaginal/anal intercourse. Secondary outcomes included sexual health attitudes, knowledge, and intentions. We examined outcomes by gender and age. Results A total of 333 participants were randomized to play the intervention (n=166) or control games (n=167): 295 (88.6%) were racial/ethnic minorities, 177 (53.2%) were boys, and the mean age was 12.9 (1.1) years. At 12 months, for the 258 (84.6%) participants with available data, 94.6% (122/129) in the intervention group versus 95.4% (123/129) in the control group delayed initiation of intercourse (relative risk=0.99, 95% CI 0.94-1.05, P=.77). Over 12 months, the intervention group demonstrated improved sexual health attitudes overall compared to the control group (least squares means [LS means] difference 0.37, 95% CI 0.01-0.72, P=.04). This improvement was observed in boys (LS means difference 0.67, P=.008), but not girls (LS means difference 0.06, P=.81), and in younger (LS means difference 0.71, P=.005), but not older participants (LS means difference 0.03, P=.92). The intervention group also demonstrated increased sexual health knowledge overall (LS means difference 1.13, 95% CI 0.64-1.61, P<.001), in girls (LS means difference 1.16, P=.001), boys (LS means difference 1.10, P=.001), younger (LS means difference 1.18, P=.001), and older (LS means difference=1.08, P=.002) participants. There were no differences in intentions to delay the initiation of intercourse between the two groups (LS means difference 0.10, P=.56). Conclusions An interactive video game intervention improves sexual health attitudes and knowledge in minority adolescents for at least 12 months. Trial Registration Clinicaltrials.gov NCT01666496; https://clinicaltrials.gov/ct2/show/NCT01666496 (Archived by WebCite at http://www.webcitation.org/6syumc9C0). PMID:28923788
Phase-sensitive, through-amplification with a double-pumped JPC
NASA Astrophysics Data System (ADS)
Sliwa, K. M.; Hatridge, M.; Frattini, N. E.; Narla, A.; Shankar, S.; Devoret, M. H.
The Josephson Parametric Converter (JPC) is now routinely used as a quantum-limited signal processing device for superconducting qubit experiments. The JPC consists of two modes, the signal and the idler, that are coupled by a ring of Josephson junctions that implements a non-degenerate, three-wave mixing process. This device is conventionally operated as either a phase-preserving parametric amplifier, or a coherent frequency converter, by pumping it at the sum or difference of the signal and idler frequencies, respectively. Here we present a novel double-pumping scheme based on theory by Metelmann and Clerk where a coherent conversion process and a gain process are simultaneously imposed between the signal and idler modes. The interference of these two processes results in a phase-sensitive amplifier with only forward gain, and which breaks the traditional gain-bandwidth limit of parametric amplification. We present results on phase-sensitive amplification with increased bandwidth, and on noise performance and dynamic range that are comparable to the traditional mode of operation. Work supported by ARO, AFOSR, NSF and YINQE.
Advancements in high-power diode laser stacks for defense applications
NASA Astrophysics Data System (ADS)
Pandey, Rajiv; Merchen, David; Stapleton, Dean; Patterson, Steve; Kissel, Heiko; Fassbender, Wilhlem; Biesenbach, Jens
2012-06-01
This paper reports on the latest advancements in vertical high-power diode laser stacks using micro-channel coolers, which deliver the most compact footprint, power scalability and highest power/bar of any diode laser package. We present electro-optical (E-O) data on water-cooled stacks with wavelengths ranging from 7xx nm to 9xx nm and power levels of up to 5.8kW, delivered @ 200W/bar, CW mode, and a power-conversion efficiency of >60%, with both-axis collimation on a bar-to-bar pitch of 1.78mm. Also, presented is E-O data on a compact, conductively cooled, hardsoldered, stack package based on conventional CuW and AlN materials, with bar-to-bar pitch of 1.8mm, delivering average power/bar >15W operating up to 25% duty cycle, 10ms pulses @ 45C. The water-cooled stacks can be used as pump-sources for diode-pumped alkali lasers (DPALs) or for more traditional diode-pumped solid-state lasers (DPSSL). which are power/brightness scaled for directed energy weapons applications and the conductively-cooled stacks as illuminators.
Ultralow-threshold multiphoton-pumped lasing from colloidal nanoplatelets in solution
Li, Mingjie; Zhi, Min; Zhu, Hai; Wu, Wen-Ya; Xu, Qing-Hua; Jhon, Mark Hyunpong; Chan, Yinthai
2015-01-01
Although multiphoton-pumped lasing from a solution of chromophores is important in the emerging fields of nonlinear optofluidics and bio-photonics, conventionally used organic dyes are often rendered unsuitable because of relatively small multiphoton absorption cross-sections and low photostability. Here, we demonstrate highly photostable, ultralow-threshold multiphoton-pumped biexcitonic lasing from a solution of colloidal CdSe/CdS nanoplatelets within a cuvette-based Fabry–Pérot optical resonator. We find that colloidal nanoplatelets surprisingly exhibit an optimal lateral size that minimizes lasing threshold. These nanoplatelets possess very large gain cross-sections of 7.3 × 10−14 cm2 and ultralow lasing thresholds of 1.2 and 4.3 mJ cm−2 under two-photon (λexc=800 nm) and three-photon (λexc=1.3 μm) excitation, respectively. The highly polarized emission from the nanoplatelet laser shows no significant photodegradation over 107 laser shots. These findings constitute a more comprehensive understanding of the utility of colloidal semiconductor nanoparticles as the gain medium in high-performance frequency-upconversion liquid lasers. PMID:26419950
Li, Yujia; Gao, Lei; Huang, Wei; Gao, Cong; Liu, Min; Zhu, Tao
2016-10-03
We report an all-fiber passively mode-locked laser based on a saturable absorber fabricated by filling short single-wall carbon nanotubes into cladding holes of grapefruit-type photonic crystal fiber. The single-wall carbon nanotube is insensitive to polarization of light for its one-dimensional structure, which suppresses the polarization dependence loss. Carbon nanotubes interact with photonic crystal fiber with ultra-weak evanescent field, which enhances the damage threshold of the saturable absorber and improves the operating stability. In our experiment, conventional soliton with a pulse duration of 1.003 ps and center wavelength of 1566.36 nm under a pump power of 240 mW is generated in a compact erbium-doped fiber laser cavity with net anomalous dispersion of -0.4102 ps2. The signal to noise ratio of the fundamental frequency component is ~80 dB. The maximum average output power of the mode-locked laser reaches 9.56 mW under a pump power of 360 mW. The output power can be further improved by a higher pump power.
Fast-Solving Quasi-Optimal LS-S3VM Based on an Extended Candidate Set.
Ma, Yuefeng; Liang, Xun; Kwok, James T; Li, Jianping; Zhou, Xiaoping; Zhang, Haiyan
2018-04-01
The semisupervised least squares support vector machine (LS-S 3 VM) is an important enhancement of least squares support vector machines in semisupervised learning. Given that most data collected from the real world are without labels, semisupervised approaches are more applicable than standard supervised approaches. Although a few training methods for LS-S 3 VM exist, the problem of deriving the optimal decision hyperplane efficiently and effectually has not been solved. In this paper, a fully weighted model of LS-S 3 VM is proposed, and a simple integer programming (IP) model is introduced through an equivalent transformation to solve the model. Based on the distances between the unlabeled data and the decision hyperplane, a new indicator is designed to represent the possibility that the label of an unlabeled datum should be reversed in each iteration during training. Using the indicator, we construct an extended candidate set consisting of the indices of unlabeled data with high possibilities, which integrates more information from unlabeled data. Our algorithm is degenerated into a special scenario of the previous algorithm when the extended candidate set is reduced into a set with only one element. Two strategies are utilized to determine the descent directions based on the extended candidate set. Furthermore, we developed a novel method for locating a good starting point based on the properties of the equivalent IP model. Combined with the extended candidate set and the carefully computed starting point, a fast algorithm to solve LS-S 3 VM quasi-optimally is proposed. The choice of quasi-optimal solutions results in low computational cost and avoidance of overfitting. Experiments show that our algorithm equipped with the two designed strategies is more effective than other algorithms in at least one of the following three aspects: 1) computational complexity; 2) generalization ability; and 3) flexibility. However, our algorithm and other algorithms have similar levels of performance in the remaining aspects.
Software-Based Real-Time Acquisition and Processing of PET Detector Raw Data.
Goldschmidt, Benjamin; Schug, David; Lerche, Christoph W; Salomon, André; Gebhardt, Pierre; Weissler, Bjoern; Wehner, Jakob; Dueppenbecker, Peter M; Kiessling, Fabian; Schulz, Volkmar
2016-02-01
In modern positron emission tomography (PET) readout architectures, the position and energy estimation of scintillation events (singles) and the detection of coincident events (coincidences) are typically carried out on highly integrated, programmable printed circuit boards. The implementation of advanced singles and coincidence processing (SCP) algorithms for these architectures is often limited by the strict constraints of hardware-based data processing. In this paper, we present a software-based data acquisition and processing architecture (DAPA) that offers a high degree of flexibility for advanced SCP algorithms through relaxed real-time constraints and an easily extendible data processing framework. The DAPA is designed to acquire detector raw data from independent (but synchronized) detector modules and process the data for singles and coincidences in real-time using a center-of-gravity (COG)-based, a least-squares (LS)-based, or a maximum-likelihood (ML)-based crystal position and energy estimation approach (CPEEA). To test the DAPA, we adapted it to a preclinical PET detector that outputs detector raw data from 60 independent digital silicon photomultiplier (dSiPM)-based detector stacks and evaluated it with a [(18)F]-fluorodeoxyglucose-filled hot-rod phantom. The DAPA is highly reliable with less than 0.1% of all detector raw data lost or corrupted. For high validation thresholds (37.1 ± 12.8 photons per pixel) of the dSiPM detector tiles, the DAPA is real time capable up to 55 MBq for the COG-based CPEEA, up to 31 MBq for the LS-based CPEEA, and up to 28 MBq for the ML-based CPEEA. Compared to the COG-based CPEEA, the rods in the image reconstruction of the hot-rod phantom are only slightly better separable and less blurred for the LS- and ML-based CPEEA. While the coincidence time resolution (∼ 500 ps) and energy resolution (∼12.3%) are comparable for all three CPEEA, the system sensitivity is up to 2.5 × higher for the LS- and ML-based CPEEA.
Wang, W; Kang, Y; Shu, X H; Shen, X D; He, B
2017-11-23
Objective: To investigate the clinical value of two-dimensional speckle tracking echocardiography(2D-STE) combined with high-sensitive cardiac troponin T (hs-cTnT) in early detection of the cardiotoxicity induced by chemotherapy drug. Methods: Seventy-five non-Hodgkin's lymphoma patients who received the CHOP regimen were recruited in this study. Conventional echocardiography and 2D-STE were performed on these patients before chemotherapy, the second day after the third course of chemotherapy (during chemotherapy) and the second day after the last course of chemotherapy (after chemotherapy). The parameters included left ventricular ejection fraction (LVEF), global longitudinal strain (LS), global circumferential strain (CS) and global radial strain (RS). The serum hs-cTNT levels were tested simultaneously. Results: Three cycles of CHOP were completed in 30 patients and 6-8 cycles of CHOP were completed in 45 patients. The LVEF of 75 patients before, during and after chemotherapy was (63.8±2.6)%, (63.8±2.8)% and (64.0±3.3)%, respectively, without significant difference ( P =0.91). However, the LS of 75 patients before, during and after chemotherapy was (-18.5±1.7)%, (-16.5±1.9)% and (-16.0±1.6)%, respectively. The CS was (-20.9±2.9)%, (-19.3±3.5)% and (-19.2±3.2)%, respectively. The RS was (39.2±6.4)%, (35.3±5.2)% and (35.0±6.2)%, respectively. The hs-cTnT was (0.001 0±0.002 0)ng/ml, (0.006 3±0.008 9)ng/ml and (0.007 3±0.003 8)ng/ml, respectively. The LS, CS and RS were significantly decreased while hs-cTnT was significantly increased during chemotherapy when compared to those before chemotherapy (all of P <0.01). Alternatively, the LS, CS, RS and hs-cTnT after chemotherapy were marginally different from those during chemotherapy (all of P >0.05). Moreover, T(LS-SD), T(CS-SD) and T(RS-SD) showed no significant difference before, during and after chemotherapy (all of P >0.05). The reduction of LS was positively associated with the enhancement of hs-cTnT after chemotherapy ( r =0.60, P <0.01). Conclusion: 2D-STE combined with hs-cTnT can effectively and precisely detect the occult cardiotoxicity induced by anthracycline.
Barone, Michele; Iannone, Andrea; Brunetti, Natale Daniele; Sebastiani, Francesco; Cecere, Onofrio; Berardi, Elsa; Antonica, Gianfranco; Di Leo, Alfredo
2015-05-01
The correlation between liver stiffness (LS) variations and portal blood flow (PBF) modifications induced by a standardized liquid meal consumption and the clinical relevance of this matter are two aspects not yet fully elucidated. Herein, we evaluated the variations of LS and PBF after a standardized liquid meal intake in patients with chronic liver disease. PBF and LS were determined after an overnight fasting period in 54 patients. They were divided in three groups according to baseline LS (absent, moderate, and severe). They consumed 200 ml of water and a standardized liquid meal (300 Kcal/200 ml) after 60 min. PBF and LS were measured at 30 min after water and liquid meal consumption. In all groups, LS and PBF values significantly increased only after meal consumption. A significant correlation between baseline LS values and post-meal increase of LS was observed. Moreover, higher basal stiffness values were associated to a larger increase of LS variation after meal consumption. The effect of the meal on LS remained statistically significant after multiple regression analysis. A significant correlation between increase of LS and PBF was found in patients with absent and moderate baseline LS. Nine patients (17%) switched from a lower to a higher level of LS after meal consumption. A low calories/low-volume meal is capable of significantly increasing LS regardless of the grade of stiffness, determining a reclassification rate of 17%. In presence of minimal or moderate stiffness, the increase of LS is significantly correlated with the augment of PBF.
Heshmat, Ramin; Kelishadi, Roya; Motamed-Gorji, Nazgol; Motlagh, Mohammad-Esmaeil; Ardalan, Gelayol; Arifirad, Tahereh; Rastad, Hadith; Asayesh, Hamid; Djalalinia, Shirin; Larijani, Bagher; Qorbani, Mostafa
2015-01-01
Adolescent obesity is a well-known worldwide issue with growing prevalence and complications. The concept of body image and complications of its misperception has been noted more recently. Life satisfaction (LS) and self-rated health (SRH) have also been known as independent morbidity and mortality factors. The objective of this study was to evaluate the associations of perceived weight status (body image) and actual body mass index (BMI), with LS and SRH in a nationally representative sample of a pediatric population in Iran, as a country located in the Middle East and North Africa region. This nationwide population-based survey was conducted among 5,570 (2,784 female and 2,786 male) Iranian students, aged 10-18 years, living in urban and rural areas of 27 provinces, which were selected via multistage sampling method. Agreement between BMI and perceived weight status (underweight, about right and overweight/obesity) was assessed. Adjusted association between BMI and perceived weight status with LS and SRH was assessed using multiple logistic regressions after adjustment for potential confounders. Nearly 40 % of the participants misperceived their body image. Misperception as overweight or underweight was found to be associated with lower odds for both LS and SRH [overweight SRH OR 0.796 (95 % CI 0.647-980), underweight SRH OR 0.701 (95 % CI 0.588-0.835), overweight LS OR 0.884 (95 % CI 0.718-998), underweight LS OR = 0.676 (95 % CI 0.577-0.793)], whereas the association between actual BMI with LS and SRH was not statistically significant (P value > 0.05). A mismatch between BMI and body weight perception was found in this study. Moreover, LS and SRH were not related with BMI, but had negative association with body weight perception.
Day-night contrast as source of health for the human circadian system.
Martinez-Nicolas, Antonio; Madrid, Juan Antonio; Rol, Maria Angeles
2014-04-01
Modern societies are characterized by a 24/7 lifestyle (LS) with no environmental differences between day and night, resulting in weak zeitgebers (weak day light, absence of darkness during night, constant environmental temperature, sedentary LS and frequent snacking), and as a consequence, in an impaired circadian system (CS) through a process known as chronodisruption. Both weak zeitgebers and CS impairment are related to human pathologies (certain cancers, metabolic syndrome and affective and cognitive disorders), but little is known about how to chronoenhance the CS. The aim of this work is to propose practical strategies for chronoenhancement, based on accentuating the day/night contrast. For this, 131 young subjects were recruited, and their wrist temperature (WT), activity, body position, light exposure, environmental temperature and sleep were recorded under free-living conditions for 1 week. Subjects with high contrast (HC) and low contrast (LC) for each variable were selected to analyze the HC effect in activity, body position, environmental temperature, light exposure and sleep would have on WT. We found that HC showed better rhythms than LC for every variable except sleep. Subjects with HC and LC for WT also demonstrated differences in LS, where HC subjects had a slightly advanced night phase onset and a general increase in day/night contrast. In addition, theoretical high day/night contrast calculated using mathematical models suggests an improvement by means of LS contrast. Finally, some individuals classified as belonging to the HC group in terms of WT when they are exposed to the LS characteristic of the LC group, while others exhibit WT arrhythmicity despite their good LS habits, revealing two different WT components: an exogenous component modified by LS and another endogenous component that is refractory to it. Therefore, intensifying day/night contrast in subject's LS has proven to be a feasible measure to chronoenhance the CS.
Munteanu, Cristian R; Pedreira, Nieves; Dorado, Julián; Pazos, Alejandro; Pérez-Montoto, Lázaro G; Ubeira, Florencio M; González-Díaz, Humberto
2014-04-01
Lectins (Ls) play an important role in many diseases such as different types of cancer, parasitic infections and other diseases. Interestingly, the Protein Data Bank (PDB) contains +3000 protein 3D structures with unknown function. Thus, we can in principle, discover new Ls mining non-annotated structures from PDB or other sources. However, there are no general models to predict new biologically relevant Ls based on 3D chemical structures. We used the MARCH-INSIDE software to calculate the Markov-Shannon 3D electrostatic entropy parameters for the complex networks of protein structure of 2200 different protein 3D structures, including 1200 Ls. We have performed a Linear Discriminant Analysis (LDA) using these parameters as inputs in order to seek a new Quantitative Structure-Activity Relationship (QSAR) model, which is able to discriminate 3D structure of Ls from other proteins. We implemented this predictor in the web server named LECTINPred, freely available at http://bio-aims.udc.es/LECTINPred.php. This web server showed the following goodness-of-fit statistics: Sensitivity=96.7 % (for Ls), Specificity=87.6 % (non-active proteins), and Accuracy=92.5 % (for all proteins), considering altogether both the training and external prediction series. In mode 2, users can carry out an automatic retrieval of protein structures from PDB. We illustrated the use of this server, in operation mode 1, performing a data mining of PDB. We predicted Ls scores for +2000 proteins with unknown function and selected the top-scored ones as possible lectins. In operation mode 2, LECTINPred can also upload 3D structural models generated with structure-prediction tools like LOMETS or PHYRE2. The new Ls are expected to be of relevance as cancer biomarkers or useful in parasite vaccine design. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Talseth-Palmer, Bente A; Holliday, Elizabeth G; Evans, Tiffany-Jane; McEvoy, Mark; Attia, John; Grice, Desma M; Masson, Amy L; Meldrum, Cliff; Spigelman, Allan; Scott, Rodney J
2013-03-26
Hereditary non-polyposis colorectal cancer (HNPCC)/Lynch syndrome (LS) is a cancer syndrome characterised by early-onset epithelial cancers, especially colorectal cancer (CRC) and endometrial cancer. The aim of the current study was to use SNP-array technology to identify genomic aberrations which could contribute to the increased risk of cancer in HNPCC/LS patients. Individuals diagnosed with HNPCC/LS (100) and healthy controls (384) were genotyped using the Illumina Human610-Quad SNP-arrays. Copy number variation (CNV) calling and association analyses were performed using Nexus software, with significant results validated using QuantiSNP. TaqMan Copy-Number assays were used for verification of CNVs showing significant association with HNPCC/LS identified by both software programs. We detected copy number (CN) gains associated with HNPCC/LS status on chromosome 7q11.21 (28% cases and 0% controls, Nexus; p =3.60E-20 and QuantiSNP; p < 1.00E-16) and 16p11.2 (46% in cases, while a CN loss was observed in 23% of controls, Nexus; p = 4.93E-21 and QuantiSNP; p = 5.00E-06) via in silico analyses. TaqMan Copy-Number assay was used for validation of CNVs showing significant association with HNPCC/LS. In addition, CNV burden (total CNV length, average CNV length and number of observed CNV events) was significantly greater in cases compared to controls. A greater CNV burden was identified in HNPCC/LS cases compared to controls supporting the notion of higher genomic instability in these patients. One intergenic locus on chromosome 7q11.21 is possibly associated with HNPCC/LS and deserves further investigation. The results from this study highlight the complexities of fluorescent based CNV analyses. The inefficiency of both CNV detection methods to reproducibly detect observed CNVs demonstrates the need for sequence data to be considered alongside intensity data to avoid false positive results.
Severe hyperkalaemia and ketoacidosis during routine treatment with an insulin pump.
Knight, G; Jennings, A M; Boulton, A J; Tomlinson, S; Ward, J D
1985-01-01
During a feasibility study of the use of insulin pumps to treat diabetes ketoacidosis occurred at a rate of 0.14 episodes/patient/year in the first year but was lower in subsequent years. A case of cardiac arrest secondary to hyperkalaemia during ketoacidosis occurred in a patient treated with a pump. The mean (SD) serum potassium concentration on presentation to hospital with ketoacidosis was significantly higher in patients treated with a pump (5.7 (1.1) mmol(mEq)/l) than those treated with conventional injections of insulin (4.9(0.9) mmol/l; p less than 0.01). The high rate of ketoacidosis and raised serum potassium concentrations during treatment with the pump creates doubt about the use of this treatment as an alternative regimen for large numbers of patients in a busy diabetic clinic. PMID:3926198
Elemental Water Impact Test: Phase 2 36-Inch Aluminum Tank Head
NASA Technical Reports Server (NTRS)
Vassilakos, Gregory J.
2014-01-01
Spacecraft are being designed based on LS-DYNA simulations of water landing impacts. The Elemental Water Impact Test (EWIT) series was undertaken to assess the accuracy of LS-DYNA water impact simulations. EWIT Phase 2 featured a 36-inch aluminum tank head. The tank head was outfitted with one accelerometer, twelve pressure transducers, three string potentiometers, and four strain gages. The tank head was dropped from heights of 1 foot and 2 feet. The focus of this report is the correlation of analytical models against test data. As a measure of prediction accuracy, peak responses from the baseline LS-DYNA model were compared to peak responses from the tests.
Comfortable, high-efficiency heat pump with desiccant-coated, water-sorbing heat exchangers
Tu, Y. D.; Wang, R. Z.; Ge, T. S.; Zheng, X.
2017-01-01
Comfortable, efficient, and affordable heating, ventilation, and air conditioning systems in buildings are highly desirable due to the demands of energy efficiency and environmental friendliness. Traditional vapor-compression air conditioners exhibit a lower coefficient of performance (COP) (typically 2.8–3.8) owing to the cooling-based dehumidification methods that handle both sensible and latent loads together. Temperature- and humidity-independent control or desiccant systems have been proposed to overcome these challenges; however, the COP of current desiccant systems is quite small and additional heat sources are usually needed. Here, we report on a desiccant-enhanced, direct expansion heat pump based on a water-sorbing heat exchanger with a desiccant coating that exhibits an ultrahigh COP value of more than 7 without sacrificing any comfort or compactness. The pump’s efficiency is doubled compared to that of pumps currently used in conventional room air conditioners, which is a revolutionary HVAC breakthrough. Our proposed water-sorbing heat exchanger can independently handle sensible and latent loads at the same time. The desiccants adsorb moisture almost isothermally and can be regenerated by condensation heat. This new approach opens up the possibility of achieving ultrahigh efficiency for a broad range of temperature- and humidity-control applications. PMID:28079171
Tackling Missing Data in Community Health Studies Using Additive LS-SVM Classifier.
Wang, Guanjin; Deng, Zhaohong; Choi, Kup-Sze
2018-03-01
Missing data is a common issue in community health and epidemiological studies. Direct removal of samples with missing data can lead to reduced sample size and information bias, which deteriorates the significance of the results. While data imputation methods are available to deal with missing data, they are limited in performance and could introduce noises into the dataset. Instead of data imputation, a novel method based on additive least square support vector machine (LS-SVM) is proposed in this paper for predictive modeling when the input features of the model contain missing data. The method also determines simultaneously the influence of the features with missing values on the classification accuracy using the fast leave-one-out cross-validation strategy. The performance of the method is evaluated by applying it to predict the quality of life (QOL) of elderly people using health data collected in the community. The dataset involves demographics, socioeconomic status, health history, and the outcomes of health assessments of 444 community-dwelling elderly people, with 5% to 60% of data missing in some of the input features. The QOL is measured using a standard questionnaire of the World Health Organization. Results show that the proposed method outperforms four conventional methods for handling missing data-case deletion, feature deletion, mean imputation, and K-nearest neighbor imputation, with the average QOL prediction accuracy reaching 0.7418. It is potentially a promising technique for tackling missing data in community health research and other applications.
An Evaluation of Gas Law Webquest Based on Active Learning Style in a Secondary School in Malaysia
ERIC Educational Resources Information Center
Alias, Norlidah; DeWitt, Dorothy; Siraj, Saedah
2014-01-01
In this study, the PTEchLS WebQuest on Gas Laws was evaluated. It was designed for Form Four students with active learning styles. The focus of the evaluation was on the usability and effectiveness of the PTechLS WebQuest. Data were collected from interviews and students' achievement scores. Two teachers and eight students volunteered to…
NASA Astrophysics Data System (ADS)
Rozemeijer, J.; Van der Grift, B.; Broers, H. P.; Berendrecht, W.; Oste, L.; Griffioen, J.
2015-12-01
In this study, we present new insights in nutrient sources and transport processes in an agricultural-dominated lowland water system based on high-frequency monitoring technology. Starting in October 2014, we have collected semi-continuous measurements of the TP and NO3 concentrations, conductivity and water temperature at a large scale pumping station at the outlet of a 576 km2 polder catchment. The semi-continuous measurements complement a water quality monitoring program at six locations within the drainage area based on conventional monthly or biweekly grab sampling. The NO3 and TP concentrations at the pumping station varied between 0.5 and 10 mgN/L and 0.1 and 0.5 mgP/L. The seasonal trends and short scale concentration dynamics clearly indicated that most of the NO3 loads at the pumping station originated from subsurface drain tubes that were active after intensive rainfall events during the winter months. A transfer function-noise model of hourly NO3 concentrations reveals that a large part of the dynamics in NO3 concentrations during the winter months can be predicted using rainfall data. In February however, NO3 concentrations were higher than predicted due to direct losses after the first manure application. The TP concentration almost doubled during operation of the pumping station. This highlights resuspension of particulate P from channel bed sediments induced by the higher flow velocities during pumping. Rainfall events that caused peaks in NO3 concentrations did not result in TP concentration peaks. Direct effects of run-off, with an association increase in the TP concentration and decrease of the NO3concentration, was only observed during rainfall event at the end of a freeze-thaw cycle. The high-frequency monitoring at the outlet of an agricultural-dominated lowland water system in combination with low-frequency monitoring within the area provided insight in nutrient sources and transport processes that are highly relevant for water quality management.
Flat nonlinear optics: metasurfaces for efficient frequency mixing
NASA Astrophysics Data System (ADS)
Nookala, Nishant; Lee, Jongwon; Liu, Yingnan; Bishop, Wells; Tymchenko, Mykhailo; Gomez-Diaz, J. Sebastian; Demmerle, Frederic; Boehm, Gerhard; Amann, Markus-Christian; Wolf, Omri; Brener, Igal; Alu, Andrea; Belkin, Mikhail A.
2017-02-01
Gradient metasurfaces, or ultrathin optical components with engineered transverse impedance gradients along the surface, are able to locally control the phase and amplitude of the scattered fields over subwavelength scales, enabling a broad range of linear components in a flat, integrable platform1-4. On the contrary, due to the weakness of their nonlinear optical responses, conventional nonlinear optical components are inherently bulky, with stringent requirements associated with phase matching and poor control over the phase and amplitude of the generated beam. Nonlinear metasurfaces have been recently proposed to enable frequency conversion in thin films without phase-matching constraints and subwavelength control of the local nonlinear phase5-8. However, the associated optical nonlinearities are far too small to produce significant nonlinear conversion efficiency and compete with conventional nonlinear components for pump intensities below the materials damage threshold. Here, we report multi-quantum-well based gradient nonlinear metasurfaces with second-order nonlinear susceptibility over 106 pm/V for second harmonic generation at a fundamental pump wavelength of 10 μm, 5-6 orders of magnitude larger than traditional crystals. Further, we demonstrate the efficacy of this approach to designing metasurfaces optimized for frequency conversion over a large range of wavelengths, by reporting multi-quantum-well and metasurface structures optimized for a pump wavelength of 6.7 μm. Finally, we demonstrate how the phase of this nonlinearly generated light can be locally controlled well below the diffraction limit using the Pancharatnam-Berry phase approach5,7,9, opening a new paradigm for ultrathin, flat nonlinear optical components.
Sie, A S; Mensenkamp, A R; Adang, E M M; Ligtenberg, M J L; Hoogerbrugge, N
2014-10-01
Recognising colorectal cancer (CRC) patients with Lynch syndrome (LS) can increase life expectancy of these patients and their close relatives. To improve identification of this under-diagnosed disease, experts suggested raising the age limit for CRC tumour genetic testing from 50 to 70 years. The present study evaluates the efficacy and cost-effectiveness of this strategy. Probabilistic efficacy and cost-effectiveness analyses were carried out comparing tumour genetic testing of CRC diagnosed at age 70 or below (experimental strategy) versus CRC diagnosed at age 50 or below (current practice). The proportions of LS patients identified and cost-effectiveness including cascade screening of relatives, were calculated by decision analytic models based on real-life data. Using the experimental strategy, four times more LS patients can be identified among CRC patients when compared with current practice. Both the costs to detect one LS patient (€9437/carrier versus €4837/carrier), and the number needed to test for detecting one LS patient (42 versus 19) doubled. When family cascade screening was included, the experimental strategy was found to be highly cost-effective according to Dutch standards, resulting in an overall ratio of €2703 per extra life-year gained in additionally tested patients. Testing all CRC tumours diagnosed at or below age 70 for LS is cost-effective. Implementation is important as relatives from the large number of LS patients that are missed by current practice, can benefit from life-saving surveillance. © The Author 2014. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Kelsey, Christina E; Torok, Kathryn S
2013-08-01
Lack of agreement on how to accurately capture disease outcomes in localized scleroderma (LS) has hindered the development of efficacious treatment protocols. The LS Cutaneous Assessment Tool (LoSCAT), consisting of the modified LS Skin Severity Index (mLoSSI) and the LS Damage Index, has potential for use in clinical trials. The goal of this article is to further evaluate the clinical responsiveness of the LoSCAT. Based on the modifiable nature of disease activity versus damage, we expected the mLoSSI to be responsive to change. At 2 study visits, a physician completed the LoSCAT and Physician Global Assessment (PGA) of Disease Activity and of Disease Damage for 29 patients with LS. Spearman correlations were used to examine the relationships between the change in the LoSCAT and the PGA scores. To evaluate contrasted group validity, patients were grouped according to disease activity classification and change scores of groups were compared. Minimal clinically important differences were calculated and compared with the standard error of measurement. Change in the mLoSSI score correlated strongly with change in the PGA of Disease Activity score, whereas change in the LS Damage Index score correlated weakly with change in the PGA of Disease Damage score. The mLoSSI and PGA of Disease Activity exhibited contrasted group validity. Minimal clinically important differences for the activity measures were greater than the respective standard errors of measurement. Only 2 study visits were included in analysis. This study gives further evidence that the LoSCAT, specifically the mLoSSI, is a responsive, valid measure of activity in LS and should be used in future treatment studies. Copyright © 2013 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.
Li, Suzanne C; Torok, Kathryn S; Pope, Elena; Dedeoglu, Fatma; Hong, Sandy; Jacobe, Heidi T; Rabinovich, C Egla; Laxer, Ronald M; Higgins, Gloria C; Ferguson, Polly J; Lasky, Andrew; Baszis, Kevin; Becker, Mara; Campillo, Sarah; Cartwright, Victoria; Cidon, Michael; Inman, Christi J; Jerath, Rita; O'Neil, Kathleen M; Vora, Sheetal; Zeft, Andrew; Wallace, Carol A; Ilowite, Norman T; Fuhlbrigge, Robert C
2012-08-01
Juvenile localized scleroderma (LS) is a chronic inflammatory skin disorder associated with substantial morbidity and disability. Although a wide range of therapeutic strategies has been reported in the literature, a lack of agreement on treatment specifics and accepted methods for clinical assessment has made it difficult to compare approaches and identify optimal therapy. Our objective was to develop standardized treatment plans, clinical assessments, and response criteria for active, moderate to high severity juvenile LS. A core group of pediatric rheumatologists, dermatologists, and a lay advisor was engaged by the Childhood Arthritis and Rheumatology Research Alliance (CARRA) to develop standardized treatment plans and assessment parameters for juvenile LS using consensus methods/nominal group techniques. Recommendations were validated in 2 face-to-face conferences with a larger group of practitioners with expertise in juvenile LS and with the full membership of CARRA, which encompasses the majority of pediatric rheumatologists in the US and Canada. Consensus was achieved on standardized treatment plans that reflect the prevailing treatment practices of CARRA members. Standardized clinical assessment methods and provisional treatment response criteria were also developed. Greater than 90% of pediatric rheumatologists responding to a survey (66% of CARRA membership) affirmed the final recommendations and agreed to utilize these consensus plans to treat patients with juvenile LS. Using consensus methodology, we have developed standardized treatment plans and assessment methods for juvenile LS. The high level of support among pediatric rheumatologists will support future comparative effectiveness studies and enable the development of evidence-based guidelines for the treatment of juvenile LS. Copyright © 2012 by the American College of Rheumatology.
Bushuev, Mark B; Pishchur, Denis P; Logvinenko, Vladimir A; Gatilov, Yuri V; Korolkov, Ilya V; Shundrina, Inna K; Nikolaenkova, Elena B; Krivopalov, Viktor P
2016-01-07
The system [FeL2](BF4)2 (1)-EtOH-H2O (L is 4-(3,5-dimethyl-1H-pyrazol-1-yl)-2-(pyridin-2-yl)-6-methylpyrimidine) shows a complicated balance between the relative stabilities of solvatomorphs and polymorphs of the complex [FeL2](BF4)2. New solvatomorphs, 1(LS)·EtOH·H2O and β-1(LS)·xH2O, were isolated in this system. They were converted into four daughter phases, 1(A/LS), 1(D/LS), 1(E/LS)·yEtOH·zH2O and 1(F/LS). On thermal cycling in sealed ampoules, the phases 1(LS)·EtOH·H2O and β-1(LS)·xH2O transform into the anhydrous phase 1(A/LS). The hysteresis loop width for the (A/LS) ↔ (A/HS) spin transition depends on the water and ethanol contents in the ampoule and varies from ca. 30 K up to 145 K. The reproducible hysteresis loop of 145 K is the widest ever reported one for a spin crossover complex. The phase 1(A/LS) combines the outstanding spin crossover properties with thermal robustness allowing for multiple cycling in sealed ampoules without degradation. The kinetics of the 1(A/LS) → 1(A/HS) transition is sigmoidal which is indicative of strong cooperative interactions. The cooperativity of the 1(A/LS) → 1(A/HS) transition is related to the formation of a 2D supramolecular structure of the phase 1(A/LS). The activation energy for the spin transition is very high (hundreds of kJ mol(-1)). The kinetics of the 1(A/HS) → 1(A/LS) transition can either be sigmoidal or exponential depending on the water and ethanol contents in the ampoule. The phases 1(D/LS) and 1(F/LS) show gradual crossover, whereas the phase 1(E/LS)·yEtOH·yH2O shows a reversible hysteretic transition associated with the solvent molecule release and uptake.
A new efficient far-infrared optically pumped laser Gas - CH3(O-18)(H)
NASA Astrophysics Data System (ADS)
Ioli, N.; Moretti, A.; Pereira, D.; Strumia, F.; Garelli, G.
1989-04-01
The (C-12)(H3)(O-18)(H) molecule has been investigated for new far-infrared laser lines by optically pumping it with a CW waveguide CO2 laser. The larger tunability (318 MHz) with respect to a conventional CO2 laser permits the pumping of many (C-12)(H3)(O-18)(H) lines. As a consequence 100 new laser lines have been discovered, ranging from 34.6 to 653.2-microns in wavelength. The infrared spectrum of (C-12)(H3)(O-18)(H) has been observed and all the fundamental vibration energies measured.
Effect of the self-pumped limiter concept on the tritium fuel cycle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finn, P.A.; Sze, D.K.; Hassanein, A.
1988-01-01
The self-pumped limiter concept for impurity control of the plasma of a fusion reactor has a major impact on the design of the tritium systems. To achieve a sustained burn, conventional limiters and divertors remove large quantities of unburnt tritium and deuterium from the plasma which must be then recycled using a plasma processing system. The self-pumped limiter which does not remove the hydrogen species, does not require any plasma processing equipment. The blanket system and the coolant processing systems acquire greater importance with the use of this unconventional impurity control system. 3 refs., 2 figs.
Nonlinear femtosecond pump-probe spectroscopy using a power-encoded soliton delay line.
Saint-Jalm, Sarah; Andresen, Esben Ravn; Bendahmane, Abdelkrim; Kudlinski, Alexandre; Rigneault, Hervé
2016-01-01
We show femtosecond time-resolved nonlinear pump-probe spectroscopy using a fiber soliton as the probe pulse. Furthermore, we exploit soliton dynamics to record an entire transient trace with a power-encoded delay sweep. The power-encoded delay line takes advantage of the dependency of the soliton trajectory in the (λ,z) space upon input power; the difference in accumulated group delay between trajectories converts a fast power sweep into a fast delay sweep. We demonstrate the concept by performing transient absorption spectroscopy in a test sample and validate it against a conventional pump-probe setup.
Aquifer Characterization and Groundwater Potential Evaluation in Sedimentary Rock Formation
NASA Astrophysics Data System (ADS)
Ashraf, M. A. M.; Yusoh, R.; Sazalil, M. A.; Abidin, M. H. Z.
2018-04-01
This study was conducted to characterize the aquifer and evaluate the ground water potential in the formation of sedimentary rocks. Electrical resistivity and drilling methods were used to develop subsurface soil profile for determining suitable location for tube well construction. The electrical resistivity method was used to infer the subsurface soil layer by use of three types of arrays, namely, the pole–dipole, Wenner, and Schlumberger arrays. The surveys were conducted using ABEM Terrameter LS System, and the results were analyzed using 2D resistivity inversion program (RES2DINV) software. The survey alignments were performed with maximum electrode spreads of 400 and 800 m by employing two different resistivity survey lines at the targeted zone. The images were presented in the form of 2D resistivity profiles to provide a clear view of the distribution of interbedded sandstone, siltstone, and shale as well as the potential groundwater zones. The potential groundwater zones identified from the resistivity results were confirmed using pumping, step drawdown, and recovery tests. The combination among the three arrays and the correlation between the well log and pumping test are reliable and successful in identifying potential favorable zones for obtaining groundwater in the study area.
Miyata, Hiroaki; Mori, Masaki; Kokudo, Norihiro; Gotoh, Mitsukazu; Konno, Hiroyuki; Wakabayashi, Go; Matsubara, Hisahiro; Watanabe, Toshiaki; Ono, Minoru; Hashimoto, Hideki; Yamamoto, Hiroyuki; Kumamaru, Hiraku; Kohsaka, Shun; Iwanaka, Tadashi
2018-01-01
To assess the use of laparoscopic surgeries (LS) and the association between its performance and hospitals' preference for LS over open surgeries. LS is increasingly used in many abdominal surgeries, albeit both with and without solid guideline recommendations. To date, the hospitals' preference (LS vs. open surgeries) and its association with in-hospital outcomes has not been evaluated. We enrolled patients undergoing 8 types of gastrointestinal surgeries in 2011-2013 in the Japanese National Clinical Database. We assessed the use of LS and the occurrences of surgery-related morbidity and mortality during the study period. Further, for 4 typical LS procedures, we assessed the hospitals' preference for LS by modeling the propensity to perform LS (over open surgeries) from patient-level factors, and estimating each institution's observed/expected (O/E) ratio for LS use. Institutions with O/E>2 were defined as LS-dominant. Using hierarchical logistic regression models, we assessed the association between LS preference and in-hospital outcomes. Among 1,377,118 patients undergoing gastrointestinal procedures in 2,336 participating hospitals, use of LS increased in all 8 procedures (35.1% to 44.7% for distal gastrectomy (DG), and 27.5% to 43.2% for right hemi colectomy (RHC)). Those operated at LS-dominant hospitals were at an increased risk of operative death (OR 1.83 [95%CI, 1.37-2.45] for DG, 1.79 [95%CI, 1.43-2.25] for RHC) compared to standard O/E level hospitals (0.5≤O/E<2.0). LS use widely increased during 2011-2013 in Japan. Facilities with higher than expected LS use had higher mortality compared to other hospitals, suggesting a need for careful patient selection and dissemination of the procedure.
Balabin, Roman M; Lomakina, Ekaterina I
2011-06-28
A multilayer feed-forward artificial neural network (MLP-ANN) with a single, hidden layer that contains a finite number of neurons can be regarded as a universal non-linear approximator. Today, the ANN method and linear regression (MLR) model are widely used for quantum chemistry (QC) data analysis (e.g., thermochemistry) to improve their accuracy (e.g., Gaussian G2-G4, B3LYP/B3-LYP, X1, or W1 theoretical methods). In this study, an alternative approach based on support vector machines (SVMs) is used, the least squares support vector machine (LS-SVM) regression. It has been applied to ab initio (first principle) and density functional theory (DFT) quantum chemistry data. So, QC + SVM methodology is an alternative to QC + ANN one. The task of the study was to estimate the Møller-Plesset (MPn) or DFT (B3LYP, BLYP, BMK) energies calculated with large basis sets (e.g., 6-311G(3df,3pd)) using smaller ones (6-311G, 6-311G*, 6-311G**) plus molecular descriptors. A molecular set (BRM-208) containing a total of 208 organic molecules was constructed and used for the LS-SVM training, cross-validation, and testing. MP2, MP3, MP4(DQ), MP4(SDQ), and MP4/MP4(SDTQ) ab initio methods were tested. Hartree-Fock (HF/SCF) results were also reported for comparison. Furthermore, constitutional (CD: total number of atoms and mole fractions of different atoms) and quantum-chemical (QD: HOMO-LUMO gap, dipole moment, average polarizability, and quadrupole moment) molecular descriptors were used for the building of the LS-SVM calibration model. Prediction accuracies (MADs) of 1.62 ± 0.51 and 0.85 ± 0.24 kcal mol(-1) (1 kcal mol(-1) = 4.184 kJ mol(-1)) were reached for SVM-based approximations of ab initio and DFT energies, respectively. The LS-SVM model was more accurate than the MLR model. A comparison with the artificial neural network approach shows that the accuracy of the LS-SVM method is similar to the accuracy of ANN. The extrapolation and interpolation results show that LS-SVM is superior by almost an order of magnitude over the ANN method in terms of the stability, generality, and robustness of the final model. The LS-SVM model needs a much smaller numbers of samples (a much smaller sample set) to make accurate prediction results. Potential energy surface (PES) approximations for molecular dynamics (MD) studies are discussed as a promising application for the LS-SVM calibration approach. This journal is © the Owner Societies 2011
Al-Asadi, H A; Al-Mansoori, M H; Ajiya, M; Hitam, S; Saripan, M I; Mahdi, M A
2010-10-11
We develop a theoretical model that can be used to predict stimulated Brillouin scattering (SBS) threshold in optical fibers that arises through the effect of Brillouin pump recycling technique. Obtained simulation results from our model are in close agreement with our experimental results. The developed model utilizes single mode optical fiber of different lengths as the Brillouin gain media. For 5-km long single mode fiber, the calculated threshold power for SBS is about 16 mW for conventional technique. This value is reduced to about 8 mW when the residual Brillouin pump is recycled at the end of the fiber. The decrement of SBS threshold is due to longer interaction lengths between Brillouin pump and Stokes wave.
An analysis of photovoltaic irrigation system for olive orchards in Greece
NASA Astrophysics Data System (ADS)
Taousanidis, N.; Gavros, K.
2016-11-01
Olive tree cultivation is of major importance in Greece. It has been proved that irrigation of olive orchards increases their production. The classic method followed is diesel pump irrigation. Since Greece favours high insolation the alternative of photovoltaic pumping is proposed. A case study for an olive orchard in Crete is studied with the two alternatives. The photovoltaic pumping system is a direct pumping system as olive trees tolerate even deficit irrigation and storage tank increases the cost. A comparison using the Life Cycle Costing method is proposed. Considerations about climate and economic conditions are taken into account and the study concludes with the profound advantage of the renewable system over the conventional one in strict economic terms.
Full-color laser cathode ray tube (L-CRT) projector
NASA Astrophysics Data System (ADS)
Kozlovskiy, Vladimir; Nasibov, Alexander S.; Popov, Yuri M.; Reznikov, Parvel V.; Skasyrsky, Yan K.
1995-04-01
A full color TV projector based on three laser cathode-ray tubes (L-CRT) is described. A water-cooled laser screen (LS) is the radiation element of the L-CRT. We have produced three main colors (blue, green and red) by using the LS made of three II-VI compounds: ZnSe ((lambda) equals 475 nm), CdS ((lambda) equals 530 nm) and ZnCdSe (630 nm). The total light flow reaches 1500 Lm, and the number of elements per line is not less than 1000. The LS efficiency may be about 10 Lm/W. In our experiments we have tested new electron optics: - (30 - 37) kV are applied to the cathode unit of the electron gun; the anode of the e-gun and the e-beam intensity modulator are under low potential; the LS has a potential + (30 - 37) kV. The accelerating voltage is divided into two parts, and this enables us to diminish the size and weight of the projector.
Frewing, Tyla M; Rapp, John T; Pastrana, Sarah J
2015-09-01
To date, researchers have not identified an efficient methodology for selecting items that will compete with automatically reinforced behavior. In the present study, we identified high preference, high stereotypy (HP-HS), high preference, low stereotypy (HP-LS), low preference, high stereotypy (LP-HS), and low preference, low stereotypy (LP-LS) items based on response allocation to items and engagement in stereotypy during one to three, 30-min free-operant competing stimulus assessments (CSAs). The results showed that access to HP-LS items decreased stereotypy for all four participants; however, the results for other items were only predictive for one participant. Reanalysis of the CSA results revealed that the HP-LS item was typically identified by (a) the combined results of the first 10 min of the three 30-min assessments or (b) the results of one 30-min assessment. The clinical implications for the use of this method, as well as future directions for research, are briefly discussed. © The Author(s) 2015.
NASA Astrophysics Data System (ADS)
Sikakwe, Gregory Udie
2018-06-01
This research modeled geological and hydrogeological controls on groundwater occurrence in Oban Massif and environs southeastern Nigeria. Topographical, hydrogeological, and structural maps, including lithology samples from drilled bores, well completion, and pumping test data in the study area were procured. Collection of coordinates of rock sample locations and structural data on strike and dip of rock exposures was collected. Geological and structural information collected was overlaid on the topographical, hydrogeological and structural map and digitized to produce the geological map of the study area. Thematic map on geological groundwater prospect map of the study was prepared using multicriteria evaluation. Relative weights were assigned to various rock types based on their relative contribution to groundwater occurrence and the map was reclassified using geographic information system (ArcGIS10.1) analysis. Depth ranges of the various lithologic units from drilled boreholes were used to construct lithologic correlation section of the boreholes across the study area using RockWorks16 Program software. Hydrogeological parameters such as storativity, specific capacity, transmissivity, drawdown, pumping rate, static water level, total depth, and well yield were computed from well completion reports and aquifer test. Results shows that the geologic groundwater prospect map was categorized into very good (28.73 m2), good (9.66 m2), moderate (35.08 m2), fair (49.38 m2), and poor (77.63 m2) zones. Aquifer parameters showed ranges such as (specific capacity (1.81-31.16 m2/day/m), transmissivity (0.0033-12 m2/day), storativity (9.4 × 10-3-2.3), drawdown (2.2-17.65 m), pumping rate (0.75-3.57 l/s), static water level (0-20.5 m), and total depth (3.3-61 m). Borehole depths obtained in the basement are shallower than those in the sedimentary area. Aquifer test parameters obtained from boreholes across the study indicate better correspondence with zones identified as good water prospect in the study. It was evident that well yield is not a very reliable aquifer performance indicator, because it depends largely on the efficiency of the pump installed. Therefore, other aquifer parameters must be employed in aquifer performance assessment. The geologic formation is paramount in determining aquifer performance. The result of this groundwater occurrence is useful as a guide for groundwater developers, which engineers in water resource management and land-use planners to select suitable areas to implement development schemes and also government agencies.
Outcomes of a Clinic-Based, Surveillance-Informed Intervention to Relink Patients to HIV Care
Bove, Joanna; Golden, Matthew R.; Dhanireddy, Shireesha; Harrington, Robert D.; Dombrowski, Julia C.
2015-01-01
Background Improving patient retention in HIV care is crucial to improving the HIV care continuum. We instituted and evaluated a relinkage program that uses clinical data to identify potentially out-of-care patients, matches those data to public health surveillance, and employs a linkage specialist (LS) to coordinate care relinkage. Methods The intervention began November 1, 2012 in the largest HIV clinic in Washington State. We evaluated program outcomes and compared patient outcomes in the year following initiation of the intervention to a historical control cohort of patients. Cox proportional hazard ratios were used to compare time to relinkage to care between cohorts, and regression models using generalized estimated equations were preformed to examine secondary outcomes of relinkage to care, engagement in care, and viral suppression. Results 753 patients were identified as “out of care” on 11/1/12. Matching with surveillance data and initial LS investigations found that 596 (79%) of these patients had moved, transferred care or were incarcerated. Of the 157 remaining patients: 40 (25%) relinked to care before LS contact, and the LS successfully contacted 38 (24%). A total of 116 (15%) patients in the intervention cohort relinked to care and 24 (20%) were contacted by the LS. Compared to the historical cohort, the time to relinkage was shorter among patients in the intervention cohort [adjusted HR=1.7 (1.2-2.3)] and a greater proportion relinked [15% vs. 10%]. Conclusions This clinic-based, surveillance-informed relinkage intervention showed statistically significant but modest effectiveness in returning out-of-care patients to HIV care compared to historical controls. PMID:26068720
Prevalence, incidence and progression of lumbar spondylosis by gender and age strata.
Muraki, Shigeyuki; Yoshimura, Noriko; Akune, Toru; Tanaka, Sakae; Takahashi, Ikuno; Fujiwara, Saeko
2014-07-01
To identify the prevalence, incidence and progression of radiographic lumbar spondylosis (LS). From the Adult Health Study conducted by the Radiation Effects Research Foundation, 1,204 participants aged 44-85 years who had lumbar spine radiographs in 1990-1992 were reexamined in 1998-2000 (mean 7.9-year interval). The radiographic severity of LS was determined by Kellgren/Lawrence (KL) grading. In the overall population, the prevalence of radiographic KL ≥ 2 and ≥ 3 LS was 52.9% and 23.6%, respectively. KL ≥ 2 LS was more prevalent in men, whereas KL ≥ 3 LS was more prevalent in women. During the 8-year follow-up, the incidence of KL ≥ 2 LS in men and women was 65.5% and 46.6%, that of KL ≥ 3 LS was 27.3% and 29.5%, that of progressive LS was 31.3% and 34.0%, and multilevel LS was 44.9% and 33.4%, respectively. Body-mass index was a risk factor for both KL ≥ 2 and KL ≥ 3 LS, after adjusting for age and sex. The present longitudinal study revealed the prevalence, incidence and progression of radiographic LS. Prevalence and incidence of KL ≥ 2 LS was higher in men than women, while, those of KL ≥ 3 were similar between men and women.
Miguel-Arribas, Andrés; Hao, Jian-An; Luque-Ortega, Juan R; Ramachandran, Gayetri; Val-Calvo, Jorge; Gago-Córdoba, César; González-Álvarez, Daniel; Abia, David; Alfonso, Carlos; Wu, Ling J; Meijer, Wilfried J J
2017-01-01
Bacterial conjugation is the process by which a conjugative element (CE) is transferred horizontally from a donor to a recipient cell via a connecting pore. One of the first steps in the conjugation process is the formation of a nucleoprotein complex at the origin of transfer ( oriT ), where one of the components of the nucleoprotein complex, the relaxase, introduces a site- and strand specific nick to initiate the transfer of a single DNA strand into the recipient cell. In most cases, the nucleoprotein complex involves, besides the relaxase, one or more additional proteins, named auxiliary proteins, which are encoded by the CE and/or the host. The conjugative plasmid pLS20 replicates in the Gram-positive Firmicute bacterium Bacillus subtilis . We have recently identified the relaxase gene and the oriT of pLS20, which are separated by a region of almost 1 kb. Here we show that this region contains two auxiliary genes that we name aux1 LS20 and aux2 LS20 , and which we show are essential for conjugation. Both Aux1 LS20 and Aux2 LS20 are predicted to contain a Ribbon-Helix-Helix DNA binding motif near their N-terminus. Analyses of the purified proteins show that Aux1 LS20 and Aux2 LS20 form tetramers and hexamers in solution, respectively, and that they both bind preferentially to oriT LS20 , although with different characteristics and specificities. In silico analyses revealed that genes encoding homologs of Aux1 LS20 and/or Aux2 LS20 are located upstream of almost 400 relaxase genes of the Rel LS20 family (MOB L ) of relaxases. Thus, Aux1 LS20 and Aux2 LS20 of pLS20 constitute the founding member of the first two families of auxiliary proteins described for CEs of Gram-positive origin.
Pump-probe surface photovoltage spectroscopy measurements on semiconductor epitaxial layers.
Jana, Dipankar; Porwal, S; Sharma, T K; Kumar, Shailendra; Oak, S M
2014-04-01
Pump-probe Surface Photovoltage Spectroscopy (SPS) measurements are performed on semiconductor epitaxial layers. Here, an additional sub-bandgap cw pump laser beam is used in a conventional chopped light geometry SPS setup under the pump-probe configuration. The main role of pump laser beam is to saturate the sub-bandgap localized states whose contribution otherwise swamp the information related to the bandgap of material. It also affects the magnitude of Dember voltage in case of semi-insulating (SI) semiconductor substrates. Pump-probe SPS technique enables an accurate determination of the bandgap of semiconductor epitaxial layers even under the strong influence of localized sub-bandgap states. The pump beam is found to be very effective in suppressing the effect of surface/interface and bulk trap states. The overall magnitude of SPV signal is decided by the dependence of charge separation mechanisms on the intensity of the pump beam. On the contrary, an above bandgap cw pump laser can be used to distinguish the signatures of sub-bandgap states by suppressing the band edge related feature. Usefulness of the pump-probe SPS technique is established by unambiguously determining the bandgap of p-GaAs epitaxial layers grown on SI-GaAs substrates, SI-InP wafers, and p-GaN epilayers grown on Sapphire substrates.
Shibasaki, S; Takamizawa, T; Nojiri, K; Imai, A; Tsujimoto, A; Endo, H; Suzuki, S; Suda, S; Barkmeier, W W; Latta, M A; Miyazaki, M
The present study determined the mechanical properties and volumetric polymerization shrinkage of different categories of resin composite. Three high viscosity bulk fill resin composites were tested: Tetric EvoCeram Bulk Fill (TB, Ivoclar Vivadent), Filtek Bulk Fill posterior restorative (FB, 3M ESPE), and Sonic Fill (SF, Kerr Corp). Two low-shrinkage resin composites, Kalore (KL, GC Corp) and Filtek LS Posterior (LS, 3M ESPE), were used. Three conventional resin composites, Herculite Ultra (HU, Kerr Corp), Estelite ∑ Quick (EQ, Tokuyama Dental), and Filtek Supreme Ultra (SU, 3M ESPE), were used as comparison materials. Following ISO Specification 4049, six specimens for each resin composite were used to determine flexural strength, elastic modulus, and resilience. Volumetric polymerization shrinkage was determined using a water-filled dilatometer. Data were evaluated using analysis of variance followed by Tukey's honestly significant difference test (α=0.05). The flexural strength of the resin composites ranged from 115.4 to 148.1 MPa, the elastic modulus ranged from 5.6 to 13.4 GPa, and the resilience ranged from 0.70 to 1.0 MJ/m 3 . There were significant differences in flexural properties between the materials but no clear outliers. Volumetric changes as a function of time over a duration of 180 seconds depended on the type of resin composite. However, for all the resin composites, apart from LS, volumetric shrinkage began soon after the start of light irradiation, and a rapid decrease in volume during light irradiation followed by a slower decrease was observed. The low shrinkage resin composites KL and LS showed significantly lower volumetric shrinkage than the other tested materials at the measuring point of 180 seconds. In contrast, the three bulk fill resin composites showed higher volumetric change than the other resin composites. The findings from this study provide clinicians with valuable information regarding the mechanical properties and polymerization kinetics of these categories of current resin composite.
Rahman, Anisur; Faqeerzada, Mohammad A; Cho, Byoung-Kwan
2018-03-14
Allicin and soluble solid content (SSC) in garlic is the responsible for its pungent flavor and odor. However, current conventional methods such as the use of high-pressure liquid chromatography and a refractometer have critical drawbacks in that they are time-consuming, labor-intensive and destructive procedures. The present study aimed to predict allicin and SSC in garlic using hyperspectral imaging in combination with variable selection algorithms and calibration models. Hyperspectral images of 100 garlic cloves were acquired that covered two spectral ranges, from which the mean spectra of each clove were extracted. The calibration models included partial least squares (PLS) and least squares-support vector machine (LS-SVM) regression, as well as different spectral pre-processing techniques, from which the highest performing spectral preprocessing technique and spectral range were selected. Then, variable selection methods, such as regression coefficients, variable importance in projection (VIP) and the successive projections algorithm (SPA), were evaluated for the selection of effective wavelengths (EWs). Furthermore, PLS and LS-SVM regression methods were applied to quantitatively predict the quality attributes of garlic using the selected EWs. Of the established models, the SPA-LS-SVM model obtained an Rpred2 of 0.90 and standard error of prediction (SEP) of 1.01% for SSC prediction, whereas the VIP-LS-SVM model produced the best result with an Rpred2 of 0.83 and SEP of 0.19 mg g -1 for allicin prediction in the range 1000-1700 nm. Furthermore, chemical images of garlic were developed using the best predictive model to facilitate visualization of the spatial distributions of allicin and SSC. The present study clearly demonstrates that hyperspectral imaging combined with an appropriate chemometrics method can potentially be employed as a fast, non-invasive method to predict the allicin and SSC in garlic. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.
THESEUS: maximum likelihood superpositioning and analysis of macromolecular structures.
Theobald, Douglas L; Wuttke, Deborah S
2006-09-01
THESEUS is a command line program for performing maximum likelihood (ML) superpositions and analysis of macromolecular structures. While conventional superpositioning methods use ordinary least-squares (LS) as the optimization criterion, ML superpositions provide substantially improved accuracy by down-weighting variable structural regions and by correcting for correlations among atoms. ML superpositioning is robust and insensitive to the specific atoms included in the analysis, and thus it does not require subjective pruning of selected variable atomic coordinates. Output includes both likelihood-based and frequentist statistics for accurate evaluation of the adequacy of a superposition and for reliable analysis of structural similarities and differences. THESEUS performs principal components analysis for analyzing the complex correlations found among atoms within a structural ensemble. ANSI C source code and selected binaries for various computing platforms are available under the GNU open source license from http://monkshood.colorado.edu/theseus/ or http://www.theseus3d.org.
Application of TDCR-Geant4 modeling to standardization of 63Ni.
Thiam, C; Bobin, C; Chauvenet, B; Bouchard, J
2012-09-01
As an alternative to the classical TDCR model applied to liquid scintillation (LS) counting, a stochastic approach based on the Geant4 toolkit is presented for the simulation of light emission inside the dedicated three-photomultiplier detection system. To this end, the Geant4 modeling includes a comprehensive description of optical properties associated with each material constituting the optical chamber. The objective is to simulate the propagation of optical photons from their creation in the LS cocktail to the production of photoelectrons in the photomultipliers. First validated for the case of radionuclide standardization based on Cerenkov emission, the scintillation process has been added to a TDCR-Geant4 modeling using the Birks expression in order to account for the light-emission nonlinearity owing to ionization quenching. The scintillation yield of the commercial Ultima Gold LS cocktail has been determined from double-coincidence detection efficiencies obtained for (60)Co and (54)Mn with the 4π(LS)β-γ coincidence method. In this paper, the stochastic TDCR modeling is applied for the case of the standardization of (63)Ni (pure β(-)-emitter; E(max)=66.98 keV) and the activity concentration is compared with the result given by the classical model. Copyright © 2012 Elsevier Ltd. All rights reserved.
A hemizygous GYG2 mutation and Leigh syndrome: a possible link?
Imagawa, Eri; Osaka, Hitoshi; Yamashita, Akio; Shiina, Masaaki; Takahashi, Eihiko; Sugie, Hideo; Nakashima, Mitsuko; Tsurusaki, Yoshinori; Saitsu, Hirotomo; Ogata, Kazuhiro; Matsumoto, Naomichi; Miyake, Noriko
2014-02-01
Leigh syndrome (LS) is an early-onset progressive neurodegenerative disorder characterized by unique, bilateral neuropathological findings in brainstem, basal ganglia, cerebellum and spinal cord. LS is genetically heterogeneous, with the majority of the causative genes affecting mitochondrial malfunction, and many cases still remain unsolved. Here, we report male sibs affected with LS showing ketonemia, but no marked elevation of lactate and pyruvate. To identify their genetic cause, we performed whole exome sequencing. Candidate variants were narrowed down based on autosomal recessive and X-linked recessive models. Only one hemizygous missense mutation (c.665G>C, p.W222S) in glycogenin-2 (GYG2) (isoform a: NM_001079855) in both affected sibs and a heterozygous change in their mother were identified, being consistent with the X-linked recessive trait. GYG2 encodes glycogenin-2 (GYG2) protein, which plays an important role in the initiation of glycogen synthesis. Based on the structural modeling, the mutation can destabilize the structure and result in protein malfunctioning. Furthermore, in vitro experiments showed mutant GYG2 was unable to undergo the self-glucosylation, which is observed in wild-type GYG2. This is the first report of GYG2 mutation in human, implying a possible link between GYG2 abnormality and LS.
Fu, Jilagamazhi; Sharma, Umesh; Sparling, Richard; Cicek, Nazim; Levin, David B
2014-07-01
Medium-chain-length polyhydroxyalkanoate (mcl-PHA) production by Pseudomonas putida LS46 was analyzed in shake-flask-based batch reactions, using pure chemical-grade glycerol (PG), biodiesel-derived "waste" glycerol (WG), and biodiesel-derived "waste" free fatty acids (WFA). Cell growth, substrate consumption, mcl-PHA accumulation within the cells, and the monomer composition of the synthesized biopolymers were monitored. The patterns of mcl-PHA synthesis in P. putida LS46 cells grown on PG and WG were similar but differed from that of cells grown with WFA. Polymer accumulation in glycerol-based cultures was stimulated by nitrogen limitation and plateaued after 48 h in both PG and WG cultures, with a total accumulation of 17.9% cell dry mass and 16.3% cell dry mass, respectively. In contrast, mcl-PHA synthesis was independent of nitrogen concentration in P. putida LS46 cells cultured with WFA, which accumulated to 29% cell dry mass. In all cases, the mcl-PHAs synthesized consisted primarily of 3-hydroxyoctanoate (C(8)) and 3-hydroxydecanoate (C(10)). WG and WFA supported similar or greater cell growth and mcl-PHA accumulation than PG under the experimental conditions used. These results suggest that biodiesel by-product streams could be used as low-cost carbon sources for sustainable mcl-PHA production.
Does life satisfaction predict five-year mortality in community-living older adults?
St John, Philip D; Mackenzie, Corey; Menec, Verena
2015-01-01
Depression and depressive symptoms predict death, but it is less clear if more general measures of life satisfaction (LS) predict death. Our objectives were to determine: (1) if LS predicts mortality over a five-year period in community-living older adults; and (2) which aspects of LS predict death. 1751 adults over the age of 65 who were living in the community were sampled from a representative population sampling frame in 1991/1992 and followed five years later. Age, gender, and education were self-reported. An index of multimorbidity and the Older American Resource Survey measured health and functional status, and the Terrible-Delightful Scale assessed overall LS as well as satisfaction with: health, finances, family, friends, housing, recreation, self-esteem, religion, and transportation. Cox proportional hazards models examined the influence of LS on time to death. 417 participants died during the five-year study period. Overall LS and all aspects of LS except finances, religion, and self-esteem predicted death in unadjusted analyses. In fully adjusted analyses, LS with health, housing, and recreation predicted death. Other aspects of LS did not predict death after accounting for functional status and multimorbidity. LS predicted death, but certain aspects of LS are more strongly associated with death. The effect of LS is complex and may be mediated or confounded by health and functional status. It is important to consider different domains of LS when considering the impact of this important emotional indicator on mortality among older adults.
Siphon effects on continuous subcutaneous insulin infusion pump delivery performance.
Zisser, Howard C; Bevier, Wendy; Dassau, Eyal; Jovanovic, Lois
2010-01-01
The objective was to quantify hydrostatic effects on continuous subcutaneous insulin infusion (CSII) pumps during basal and bolus insulin delivery. We tested CSII pumps from Medtronic Diabetes (MiniMed 512 and 515), Smiths Medical (Deltec Cozmo 1700), and Insulet (OmniPod) using insulin aspart (Novolog, Novo Nordisk). Pumps were filled and primed per manufacturer's instructions. The fluid level change was measured using an inline graduated glass pipette (100 microl) when the pipette was moved in relation to the pump (80 cm Cosmo and 110 cm Medtronics) and when level. Pumps were compared during 1 and 5 U boluses and basal insulin delivery of 1.0 and 1.5 U/h. Pronounced differences were seen during basal delivery in pumps using 80-100 cm tubing. For the 1 U/h rate, differences ranged from 74.5% of the expected delivery when the pumps were below the pipettes and pumping upward to 123.3% when the pumps were above the pipettes and pumping downward. For the 1.5 U/h rate, differences ranged from 86.7% to 117.0% when the pumps were below or above the pipettes, respectively. Compared to pumps with tubing, OmniPod performed with significantly less variation in insulin delivery. Changing position of a conventional CSII pump in relation to its tubing results in significant changes in insulin delivery. The siphon effect in the tubing may affect the accuracy of insulin delivery, especially during low basal rates. This effect has been reported when syringe pumps were moved in relation to infusion sites but has not been reported with CSII pumps. 2010 Diabetes Technology Society.
Experimental analysis of direct-expansion ground-coupled heat pump systems
NASA Astrophysics Data System (ADS)
Mei, V. C.; Baxter, V. D.
1991-09-01
Direct-expansion ground-coil-coupled (DXGC) heat pump systems have certain energy efficiency advantages over conventional ground-coupled heat pump (GCHP) systems. Principal among these advantages are that the secondary heat transfer fluid heat exchanger and circulating pump are eliminated. While the DXGC concept can produce higher efficiencies, it also produces more system design and environmental problems (e.g., compressor starting, oil return, possible ground pollution, and more refrigerant charging). Furthermore, general design guidelines for DXGC systems are not well documented. A two-pronged approach was adopted for this study: (1) a literature survey, and (2) a laboratory study of a DXGC heat pump system with R-22 as the refrigerant, for both heating and cooling mode tests done in parallel and series tube connections. The results of each task are described in this paper. A set of general design guidelines was derived from the test results and is also presented.
Large dynamic range terahertz spectrometers based on plasmonic photomixers (Conference Presentation)
NASA Astrophysics Data System (ADS)
Wang, Ning; Javadi, Hamid; Jarrahi, Mona
2017-02-01
Heterodyne terahertz spectrometers are highly in demand for space explorations and astrophysics studies. A conventional heterodyne terahertz spectrometer consists of a terahertz mixer that mixes a received terahertz signal with a local oscillator signal to generate an intermediate frequency signal in the radio frequency (RF) range, where it can be easily processed and detected by RF electronics. Schottky diode mixers, superconductor-insulator-superconductor (SIS) mixers and hot electron bolometer (HEB) mixers are the most commonly used mixers in conventional heterodyne terahertz spectrometers. While conventional heterodyne terahertz spectrometers offer high spectral resolution and high detection sensitivity levels at cryogenic temperatures, their dynamic range and bandwidth are limited by the low radiation power of existing terahertz local oscillators and narrow bandwidth of existing terahertz mixers. To address these limitations, we present a novel approach for heterodyne terahertz spectrometry based on plasmonic photomixing. The presented design replaces terahertz mixer and local oscillator of conventional heterodyne terahertz spectrometers with a plasmonic photomixer pumped by an optical local oscillator. The optical local oscillator consists of two wavelength-tunable continuous-wave optical sources with a terahertz frequency difference. As a result, the spectrometry bandwidth and dynamic range of the presented heterodyne spectrometer is not limited by radiation frequency and power restrictions of conventional terahertz sources. We demonstrate a proof-of-concept terahertz spectrometer with more than 90 dB dynamic range and 1 THz spectrometry bandwidth.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davlin, Thomas
The overall deliverable from the project is the design, construction and commissioning of a detention facility heating and cooling system that minimizes ownership costs and maximizes efficiency (and therefore minimizes environmental impact). The primary deliverables were the proof of concept for the application of geothermal systems for an institutional facility and the ongoing, quarterly system operating data downloads to the Department of Energy . The primary advantage of geothermal based heat pump systems is the higher efficiency of the system compared to a conventional chiller, boiler, cooling tower based system. The higher efficiency results in a smaller environmental foot printmore » and lower energy costs for the detention facility owner, Lancaster County. The higher efficiency for building cooling is primarily due to a more constant compressor condensing temperature with the geothermal well field acting as a thermal “sink” (in place of the conventional system’s cooling tower). In the heating mode, Ground Couple Heat Pump (GCHP) systems benefits from the advantage of a heat pump Coefficient of Performance (COP) of approximately 3.6, significantly better than a conventional gas boiler. The geothermal well field acting as a thermal “source” allows the heat pumps to operate efficiently in the heating mode regardless of ambient temperatures. The well field is partially located in a wetland with a high water table so, over time, the project will be able to identify the thermal loading characteristics of a well field located in a high water table location. The project demonstrated how a large geothermal well field can be installed in a wetland area in an economical and environmentally sound manner. Finally, the SW 40th Street Thermal Energy Plant project demonstrates the benefits of providing domestic hot water energy, as well as space heating, to help balance well filed thermal loading in a cooling dominated application. During the period of August 2012 thru March 2014, with the detention facility occupied for the final seven months, the well field supply water temperatures to the heat pumps dropped to a minimum of 39°F and reached a maximum temperature of 68 °F while providing 15,819 MMBtu of cooling energy and 27,467 MMBtu of heating energy. During this period the peak recorded system cooling load was 610 tons and the peak heating load was 8.4 MMBtu. The DEC is currently evaluating the most beneficial electric rate for plant operations. Total project cost of $16.9 million was approximately $3.2 million less than the estimate provided in the grant application. The reduction in project costs were primarily due to favorable construction material prices as well as strong competition in the local construction contractor market. The DEC plant reached the substantial completion milestone in December 2011 and began providing thermal service to the detention facility in January 2012 when the building’s HVAC system was ready to accept heating service. The plant reached commercial operating status on August 1, 2012. However, due to construction delays, the detention facility was not occupied until September of 2013. The detention facility construction delays also impacted the installation and commissioning of the project’s dedicated domestic hot water heat pump. Final coordination with the detention facility’s building management system vendor to establish network links for the exchange of date is currently being completed. This will allow the development of control sequences for the optimal operation of the domestic hot water system.« less
Solar-thermal jet pumping for irrigation
NASA Astrophysics Data System (ADS)
Clements, L. D.; Dellenback, P. A.; Bell, C. A.
1980-01-01
This paper describes a novel concept in solar powered irrigation pumping, gives measured performance data for the pump unit, and projected system performance. The solar-thermal jet pumping concept is centered around a conventional jet eductor pump which is commercially available at low cost. The jet eductor pump is powered by moderate temperature, moderate pressure Refrigerant-113 vapor supplied by a concentrating solar collector field. The R-113 vapor is direct condensed by the produced water and the two fluids are separated at the surface. The water goes on to use and the R-113 is repressurized and returned to the solar field. The key issue in the solar-thermal jet eductor concept is the efficiency of pump operation. Performance data from a small scale experimental unit which utilizes an electrically heated boiler in place of the solar field is presented. The solar-thermal jet eductor concept is compared with other solar irrigation concepts and optimal application situations are identified. Though having lower efficiencies than existing Rankine cycle solar-thermal irrigation systems, the mechanical and operational simplicity of this concept make it competitive with other solar powered irrigation schemes.
NASA Astrophysics Data System (ADS)
Tichý, Ondřej; Šmídl, Václav; Hofman, Radek; Stohl, Andreas
2016-11-01
Estimation of pollutant releases into the atmosphere is an important problem in the environmental sciences. It is typically formalized as an inverse problem using a linear model that can explain observable quantities (e.g., concentrations or deposition values) as a product of the source-receptor sensitivity (SRS) matrix obtained from an atmospheric transport model multiplied by the unknown source-term vector. Since this problem is typically ill-posed, current state-of-the-art methods are based on regularization of the problem and solution of a formulated optimization problem. This procedure depends on manual settings of uncertainties that are often very poorly quantified, effectively making them tuning parameters. We formulate a probabilistic model, that has the same maximum likelihood solution as the conventional method using pre-specified uncertainties. Replacement of the maximum likelihood solution by full Bayesian estimation also allows estimation of all tuning parameters from the measurements. The estimation procedure is based on the variational Bayes approximation which is evaluated by an iterative algorithm. The resulting method is thus very similar to the conventional approach, but with the possibility to also estimate all tuning parameters from the observations. The proposed algorithm is tested and compared with the standard methods on data from the European Tracer Experiment (ETEX) where advantages of the new method are demonstrated. A MATLAB implementation of the proposed algorithm is available for download.
Yo, In Ku; Park, Jin Woong; Lee, Jong Joon; Lee, Jung Hyun; Won, In Sik; Na, Sun Young; Jang, Pil Kyu; Park, Pyung Hwa; Choi, Duck Joo; Kim, Yun Soo; Kim, Ju Hyun
2015-01-01
Background/Aims Liver stiffness (LS) as assessed by transient elastography (TE) can change longitudinally in patients with chronic hepatitis B (CHB). The aim of this study was to identify the factors that improve LS. Methods Between April 2007 and December 2012, 151 patients with CHB who underwent two TE procedures with an interval of about 2 years were enrolled. Ninety-six of the 151 patients were treated with nucleos(t)ide analogues [the antiviral therapy (+) group], while the remaining 55 patients were not [the antiviral therapy (-) group]. The two groups of patients were stratified according to whether they exhibited an improvement or a deterioration in LS during the study period (defined as an LS change of ≤0 or >0 kPa, respectively, over a 1-year period), and their data were compared. Results No differences were observed between the antiviral therapy (+) and (-) groups with respect to either their clinical characteristics or their initial LS. The observed LS improvement was significantly greater in the antiviral therapy (+) group than in the antiviral therapy (-) group (-3.0 vs. 0.98 kPa, P=0.011). In the antiviral therapy (+) group, the initial LS was higher in the LS improvement group (n=63) than in the LS deterioration group (n=33; 7.9 vs. 4.8 kPa, P<0.001). However, there were no differences in any other clinical characteristic. In the antiviral therapy (-) group, the initial LS was also higher in the LS improvement group (n=29) than in the LS deterioration group (n=26; 8.3 vs. 6.5 kPa, P=0.021), with no differences in any other clinical characteristic. Conclusions A higher initial LS was the only factor associated with LS improvement in patients with CHB in this study. PMID:25834800
Yo, In Ku; Kwon, Oh Sang; Park, Jin Woong; Lee, Jong Joon; Lee, Jung Hyun; Won, In Sik; Na, Sun Young; Jang, Pil Kyu; Park, Pyung Hwa; Choi, Duck Joo; Kim, Yun Soo; Kim, Ju Hyun
2015-03-01
Liver stiffness (LS) as assessed by transient elastography (TE) can change longitudinally in patients with chronic hepatitis B (CHB). The aim of this study was to identify the factors that improve LS. Between April 2007 and December 2012, 151 patients with CHB who underwent two TE procedures with an interval of about 2 years were enrolled. Ninety-six of the 151 patients were treated with nucleos(t)ide analogues [the antiviral therapy (+) group], while the remaining 55 patients were not [the antiviral therapy (-) group]. The two groups of patients were stratified according to whether they exhibited an improvement or a deterioration in LS during the study period (defined as an LS change of ≤0 or >0 kPa, respectively, over a 1-year period), and their data were compared. No differences were observed between the antiviral therapy (+) and (-) groups with respect to either their clinical characteristics or their initial LS. The observed LS improvement was significantly greater in the antiviral therapy (+) group than in the antiviral therapy (-) group (-3.0 vs. 0.98 kPa, P=0.011). In the antiviral therapy (+) group, the initial LS was higher in the LS improvement group (n=63) than in the LS deterioration group (n=33; 7.9 vs. 4.8 kPa, P<0.001). However, there were no differences in any other clinical characteristic. In the antiviral therapy (-) group, the initial LS was also higher in the LS improvement group (n=29) than in the LS deterioration group (n=26; 8.3 vs. 6.5 kPa, P=0.021), with no differences in any other clinical characteristic. A higher initial LS was the only factor associated with LS improvement in patients with CHB in this study.
Fusco, Fernanda B.; Gomes, Diego J.; Bispo, Kely C. S.; Toledo, Veronica P.; Barbeiro, Denise F.; Capelozzi, Vera L.; Furukawa, Luzia N. S.; Velosa, Ana P. P.; Teodoro, Walcy R.; Heimann, Joel C.; Quintao, Eder C. R.; Passarelli, Marisa; Nakandakare, Edna R.; Catanozi, Sergio
2017-01-01
This study investigated the influence of sodium restriction and antihypertensive drugs on atherogenesis utilizing hypertensive (H) low-density lipoprotein-receptor knockout mice treated or not with losartan (Los) or hydralazine (Hyd) and fed low-sodium (LS) or normal-sodium (NS) chow. Despite reducing the blood pressure (BP) of H-LS mice, the LS diet caused arterial lipid infiltration due to increased plasma total cholesterol (TC) and triglycerides (TG). Los and Hyd reduced the BP of H-LS mice, and Los effectively prevented arterial injury, likely by reducing plasma TG and nonesterified fatty acids. Aortic lipid infiltration was lower in Los-treated H-LS mice (H-LS+Los) than in normotensive (N)-LS and H-LS mice. Aortic angiotensin II type 1 (AT1) receptor content was greater in H-NS than H-LS mice and in H-LS+Hyd than H-LS+Los mice. Carboxymethyl-lysine (CML) and receptor for advanced glycation end products (RAGE) immunostaining was greater in H-LS than H-NS mice. CML and RAGE levels were lower in LS animals treated with antihypertensive drugs, and Hyd enhanced the AT1 receptor level. Hyd also increased the gene expression of F4/80 but not tumor necrosis factor-α, interleukin (IL)-1β, IL-6, IL-10, intercellular adhesion molecule-1 or cluster of differentiation 66. The novelty of the current study is that in a murine model of simultaneous hypertension and hyperlipidemia, the pleiotropic effect of chronic, severe sodium restriction elicited aortic damage even with reduced BP. These negative effects on the arterial wall were reduced by AT1 receptor antagonism, demonstrating the influence of angiotensin II in atherogenesis induced by a severely LS diet. PMID:28481921
de Lima, Alberto Alves; Bettati, María Ines; Baratta, Sergio; Falconi, Mariano; Sokn, Fernando; Galli, Amanda; Barrero, Carlos; Cagide, Arturo; Iglesias, Ricardo
2006-11-01
To identify the learning styles of a group of cardiology residents (R) undergoing a training program at the University of Buenos Aires and to identify correlations of these styles. Statistical data were obtained through a 120-question survey developed by Vermunt and colleagues, which identified four different learning styles: construction-directed; reproduction-directed; application-directed; and undirected. Four variables were identified [gender, previous experience as a teaching assistant (TA) in medical school, university final average (FA) and the public or private institution/centre of origin] in order to analyse level of correlation with learning styles (LS). Between April 2001 and April 2002, 149 residents (R) completed the survey. Average age was 29 (+/-2.7) years old; with 63% being men. The predominant LS were oriented toward knowledge application. In terms of variables, no differences regarding gender were detected; the R with TA showed undirected LS characteristics; those with a low FA registered a tendency towards reproduction-directed LS; and those residents at public/state medical centres indicated construction-directed LS tendencies. An application-directed learning style predominates in this group of residents. Information regarding learning styles can provide foundations upon which arguments can be made for changes in education that are traditionally not evidence-based.
HEAVY METAL LOADED PLASTIC SCINTILLATING COMPOSITIONS
Hyman, M. Jr.
1962-06-26
Thls lnventlon relates to a plastlc sclntlllatlon composltlon havlng lncorporated ln the base plastlc a lead compound. Thls compound forms a haze- free sclntillator. The lead compound has the general formula (R/sub 4/) x from the group consisting of hydrogen, alky, and phenyl, R4 ls selected from the group conslstlng of acrylyl and methacryiyl radlcals, and x ls a number from 0,5 to 1; however, when R/sub 1/, R/sub 2/, and R/sub 3/ are all hydrogen the x ls equal to 1. The phosphor ln the sclntlllatlng compositlon and the lead compound can be dlssolved ln a polymerlc resln selected from the group conslsting of polyvinyl toluene and copolymers of vlnyl toluene and cyclohexyl methacrylate. (AEC)
Taylor, Sophie; Spugnini, Enrico Pierluigi; Assaraf, Yehuda G; Azzarito, Tommaso; Rauch, Cyril; Fais, Stefano
2015-11-01
Despite the major progresses in biomedical research and the development of novel therapeutics and treatment strategies, cancer is still among the dominant causes of death worldwide. One of the crucial challenges in the clinical management of cancer is primary (intrinsic) and secondary (acquired) resistance to both conventional and targeted chemotherapeutics. Multiple mechanisms have been identifiedthat underlie intrinsic and acquired chemoresistance: these include impaired drug uptake, increased drug efflux, deletion of receptors, altered drug metabolism, quantitative and qualitative alterations in drug targets, increased DNA damage repair and various mechanisms of anti-apoptosis. The fast efflux of anticancer drugs mediated by multidrug efflux pumps and the partial or complete reversibility of chemoresistance combined with the absence of genetic mutations suggests a multifactorial process. However, a growing body of recent evidence suggests that chemoresistance is often triggered by the highly acidic microenvironment of tumors. The vast majority of drugs, including conventional chemotherapeutics and more recent biological agents, are weak bases that are quickly protonated and neutralized in acidic environments, such as the extracellular microenvironment and the acidic organelles of tumor cells. It is therefore essential to develop new strategies to overcome the entrapment and neutralization of weak base drugs. One such strategy is the use of proton pump inhibitors which can enhance tumor chemosensitivity by increasing the pH of the tumor microenvironment. Recent clinical trials in animals with spontaneous tumors have indicated that patient alkalization is capable of reversing acquired chemoresistance in a large percentage of tumors that are refractory to chemotherapy. Of particular interest was the benefit of alkalization for patients undergoing metronomic regimens which are becoming more widely used in veterinary medicine. Overall, these results provide substantial new evidence that altering the acidic tumor microenvironment is an effective, well tolerated and low cost strategy for the overcoming of anticancer drug resistance. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Groth, H.
1982-11-01
The utilization of photovoltaic generators in measuring and signalling installations, communication systems, water pumping, and electric power plants is discussed. The advantages of solar generators over conventional power supply equipment are outlined.
Sawada, Yoshiaki; Umetsu, Asami; Komatsu, Yuki; Kitamura, Jun; Suzuki, Hiroyuki; Asami, Tadao; Fukuda, Machiko; Honda, Ichiro; Mitsuhashi, Wataru; Nakajima, Masatoshi; Toyomasu, Tomonobu
2012-01-01
DELLA proteins are negative regulators of the signaling of gibberellin (GA), a phytohormone regulating plant growth. DELLA degradation is triggered by its interaction with GID1, a soluble GA receptor, in the presence of bioactive GA. We isolated cDNA from a spliced variant of LsDELLA1 mRNA in lettuce, and named it LsDELLA1sv. It was deduced that LsDELLA1sv encodes truncated LsDELLA1, which has DELLA and VHYNP motifs at the N terminus but lacks part of the C-terminal GRAS domain. The recombinant LsDELLA1sv protein interacted with both Arabidopsis GID1 and lettuce GID1s in the presence of GA. A yeast two-hybrid assay suggested that LsDELLA1sv interacted with LsDELLA1. The ratio of LsDELLA1sv to LsDELLA1 transcripts was higher in flower samples at the late reproductive stage and seed samples (dry seeds and imbibed seeds) than in the other organ samples examined. This study suggests that LsDELLA1sv is a possible modulator of GA signaling in lettuce.
NASA Astrophysics Data System (ADS)
Ambrose, J. L.; Reidmiller, D. R.; Jaffe, D. A.
2011-09-01
We measured O3, CO, Hg, sub-micron particle scattering of mid-visible light (σsp), and water vapor (WV) at the Mt. Bachelor Observatory (MBO) in central Oregon, USA since 2004. The data were used to identify sources of large ozone enhancements in the lower free troposphere (FT). A total of 25 high-ozone events, defined as time periods when the 8-h averaged O3 mixing ratio was >70.0 ppbv, were recorded. The events occurred between early March and late September. For 18 of the 25 event days we were able to identify sources based on (1) relative enhancements of O3, CO, Hg and WV compared with the corresponding monthly distributions and (2) supporting data from the Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model, the Navy Aerosol Analysis and Prediction System (NAAPS) global aerosol model, and Moderate Resolution Imaging Spectroradiometer (MODIS) satellite-derived active fire counts from the Fire Information for Resource Management System (FIRMS). Our analysis suggests that enhanced O3 levels during all the identified events were transported to MBO in the FT and were driven mostly by subsidence of O3-rich air masses from the upper troposphere/lower stratosphere (UT/LS), Asian long range transport (ALRT) and mixed ALRT + UT/LS influences. The UT/LS events were depleted in CO and total atmospheric mercury (TAM) compared to monthly median values. Levels of O3 and CO tended to be anti-correlated during UT/LS events, consistent with transport from clean regions in the UT. Conversely, the ALRT events were characterized by concomitant enhancements in CO and TAM with mean values during each event that were >70th percentile values for the months during which the events occurred. Unlike for UT/LS events, levels of O3 and CO during ALRT events tended to be correlated, consistent with photochemical O3 production in polluted air masses transported across the Pacific. The mixed ALRT + UT/LS events exhibited characteristics that were intermediate between those of the ALRT and UT/LS events. For the classifiable cases the fractional distribution of each event type was: UT/LS, ˜44% (n = 8); ALRT + UT/LS, ˜33% (n = 6); ALRT, ˜22% (n = 4). In terms of the total number of classifiable high-ozone event hours UT/LS, ALRT + UT/LS and ALRT events accounted for ˜52% (t = 85), ˜36% (t = 59) and ˜13% (t = 21), respectively. The results indicate that downward mixing of O3-rich air masses from the UT/LS together with trans-Pacific transport of urban/industrial and biomass burning emissions from the Asian continent are the most important mechanisms for delivering high O3 levels (i.e., 8-h averages >70.0 ppbv) to the lower FT in the Pacific Northwest.
Immune Profiling of Premalignant Lesions in Patients With Lynch Syndrome.
Chang, Kyle; Taggart, Melissa W; Reyes-Uribe, Laura; Borras, Ester; Riquelme, Erick; Barnett, Reagan M; Leoni, Guido; San Lucas, F Anthony; Catanese, Maria T; Mori, Federica; Diodoro, Maria G; You, Y Nancy; Hawk, Ernest T; Roszik, Jason; Scheet, Paul; Kopetz, Scott; Nicosia, Alfredo; Scarselli, Elisa; Lynch, Patrick M; McAllister, Florencia; Vilar, Eduardo
2018-04-16
Colorectal carcinomas in patients with Lynch syndrome (LS) arise in a background of mismatch repair (MMR) deficiency, display a unique immune profile with upregulation of immune checkpoints, and response to immunotherapy. However, there is still a gap in understanding the pathogenesis of MMR-deficient colorectal premalignant lesions, which is essential for the development of novel preventive strategies for LS. To characterize the immune profile of premalignant lesions from a cohort of patients with LS. Whole-genome transcriptomic analysis using next-generation sequencing was performed in colorectal polyps and carcinomas of patients with LS. As comparator and model of MMR-proficient colorectal carcinogenesis, we used samples from patients with familial adenomatous polyposis (FAP). In addition, a total of 47 colorectal carcinomas (6 hypermutants and 41 nonhypermutants) were obtained from The Cancer Genome Atlas (TCGA) for comparisons. Samples were obtained from the University of Texas MD Anderson Cancer Center and "Regina Elena" National Cancer Institute, Rome, Italy. All diagnoses were confirmed by genetic testing. Polyps were collected at the time of endoscopic surveillance and tumors were collected at the time of surgical resection. The data were analyzed from October 2016 to November 2017. Assessment of the immune profile, mutational signature, mutational and neoantigen rate, and pathway enrichment analysis of neoantigens in LS premalignant lesions and their comparison with FAP premalignant lesions, LS carcinoma, and sporadic colorectal cancers from TCGA. The analysis was performed in a total of 28 polyps (26 tubular adenomas and 2 hyperplastic polyps) and 3 early-stage LS colorectal tumors from 24 patients (15 [62%] female; mean [SD] age, 48.12 [15.38] years) diagnosed with FAP (n = 10) and LS (n = 14). Overall, LS polyps presented with low mutational and neoantigen rates but displayed a striking immune activation profile characterized by CD4 T cells, proinflammatory (tumor necrosis factor, interleukin 12) and checkpoint molecules (LAG3 [lymphocyte activation gene 3] and PD-L1 [programmed cell death 1 ligand 1]). This immune profile was independent of mutational rate, neoantigen formation, and MMR status. In addition, we identified a small subset of LS polyps with high mutational and neoantigen rates that were comparable to hypermutant tumors and displayed additional checkpoint (CTLA4 [cytotoxic T-lymphocyte-associated protein 4]) and neoantigens involved in DNA damage response (ATM and BRCA1 signaling). These findings challenge the canonical model, based on the observations made in carcinomas, that emphasizes a dependency of immune activation on the acquisition of high levels of mutations and neoantigens, thus opening the door to the implementation of immune checkpoint inhibitors and vaccines for cancer prevention in LS.
Fiellin, Lynn E; Hieftje, Kimberly D; Pendergrass, Tyra M; Kyriakides, Tassos C; Duncan, Lindsay R; Dziura, James D; Sawyer, Benjamin G; Mayes, Linda; Crusto, Cindy A; Forsyth, Brian Wc; Fiellin, David A
2017-09-18
Human immunodeficiency virus (HIV) disproportionately impacts minority youth. Interventions to decrease HIV sexual risk are needed. We hypothesized that an engaging theory-based digital health intervention in the form of an interactive video game would improve sexual health outcomes in adolescents. Participants aged 11 to 14 years from 12 community afterschool, school, and summer programs were randomized 1:1 to play up to 16 hours of an experimental video game or control video games over 6 weeks. Assessments were conducted at 6 weeks and at 3, 6, and 12 months. Primary outcome was delay of initiation of vaginal/anal intercourse. Secondary outcomes included sexual health attitudes, knowledge, and intentions. We examined outcomes by gender and age. A total of 333 participants were randomized to play the intervention (n=166) or control games (n=167): 295 (88.6%) were racial/ethnic minorities, 177 (53.2%) were boys, and the mean age was 12.9 (1.1) years. At 12 months, for the 258 (84.6%) participants with available data, 94.6% (122/129) in the intervention group versus 95.4% (123/129) in the control group delayed initiation of intercourse (relative risk=0.99, 95% CI 0.94-1.05, P=.77). Over 12 months, the intervention group demonstrated improved sexual health attitudes overall compared to the control group (least squares means [LS means] difference 0.37, 95% CI 0.01-0.72, P=.04). This improvement was observed in boys (LS means difference 0.67, P=.008), but not girls (LS means difference 0.06, P=.81), and in younger (LS means difference 0.71, P=.005), but not older participants (LS means difference 0.03, P=.92). The intervention group also demonstrated increased sexual health knowledge overall (LS means difference 1.13, 95% CI 0.64-1.61, P<.001), in girls (LS means difference 1.16, P=.001), boys (LS means difference 1.10, P=.001), younger (LS means difference 1.18, P=.001), and older (LS means difference=1.08, P=.002) participants. There were no differences in intentions to delay the initiation of intercourse between the two groups (LS means difference 0.10, P=.56). An interactive video game intervention improves sexual health attitudes and knowledge in minority adolescents for at least 12 months. Clinicaltrials.gov NCT01666496; https://clinicaltrials.gov/ct2/show/NCT01666496 (Archived by WebCite at http://www.webcitation.org/6syumc9C0). ©Lynn E Fiellin, Kimberly D Hieftje, Tyra M Pendergrass, Tassos C Kyriakides, Lindsay R Duncan, James D Dziura, Benjamin G Sawyer, Linda Mayes, Cindy A Crusto, Brian WC Forsyth, David A Fiellin. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 18.09.2017.
2012-01-01
Background Life satisfaction (LS) of cerebrovascular disease survivors and their family caregivers may relate to socioeconomic factors, impaired functions, health-related quality of life (QoL), but their respective influences remain unclear. This study assessed, two years post-stroke onset, the effects of these factors on patients’ LS and family caregivers’ LS in Luxembourg. Methods All stroke patients admitted to all hospitals in Luxembourg were identified by the ‘Inspection Général de la Sécurité Sociale’ using the only national system database for care expenditure reimbursement. Their diagnosis was confirmed by medical investigator. The sample included ninety four patients living at home having given consent (mean age 65.5 years) and sixty two main caregivers (mean age 59.3 years). Questionnaires were completed during face-to-face interviews. LS was assessed via European single question (range 1–10), survivors’ QoL via Newsqol (11 dimensions), and caregivers’ QoL via Whoqol-bref (4 domains) (range 0–100). Data were analysed using multiple regression models. Results Two years after stroke onset, 44.7% of patients suffered from impaired sensory function, 35.1% from impaired motor function, and 31.9% from impaired memory function. Mean patient’ LS was 7.1/10 (SD 1.9). It was higher in women (+12.4) and lower among unemployed socioeconomically active patients (−13.1, vs. retired people). Adjusted for sex, occupation, impaired motor and memory functions, LS positively correlated with scores of Newsqol feelings, sleep, emotion, cognition and pain dimensions (slopes 0.20 to 0.31), but did not correlate with those of caregivers’ Whoqol-bref domains. Family caregiver’ LS was 7.2 (SD 1.7). It was lower in those with patients suffering from impaired memory function (−12.8) as well as from feelings and emotion issues (slopes 0.22). It was associated with all caregivers’ Whoqol-bref domains (physical health, psychological health, environment, and social relationships) (slopes 0.53 to 0.68). Conclusions Two-year post-cerebrovascular disease patient’ LS was associated with gender, occupation, and impaired memory function. It correlated with feelings, sleep, emotion, cognition, and pain issues. Family caregivers of patients with impaired memory function had lower LS. Family caregiver’ LS correlated with dimensions of patients’ feelings (less independent, yourself, life changed, depressed, useless, less control because of stroke) and emotion (get more emotional, fear of another stroke or to become dependent on others), and with their own QoL. LS, Newsqol, and Whoqol appeared to be appropriate tools. Our findings may be useful for policy makers in relation to family and medical-social issues of stroke home-based rehabilitation. PMID:23009364
Baumann, Michèle; Couffignal, Sophie; Le Bihan, Etienne; Chau, Nearkasen
2012-09-25
Life satisfaction (LS) of cerebrovascular disease survivors and their family caregivers may relate to socioeconomic factors, impaired functions, health-related quality of life (QoL), but their respective influences remain unclear. This study assessed, two years post-stroke onset, the effects of these factors on patients' LS and family caregivers' LS in Luxembourg. All stroke patients admitted to all hospitals in Luxembourg were identified by the 'Inspection Général de la Sécurité Sociale' using the only national system database for care expenditure reimbursement. Their diagnosis was confirmed by medical investigator. The sample included ninety four patients living at home having given consent (mean age 65.5 years) and sixty two main caregivers (mean age 59.3 years). Questionnaires were completed during face-to-face interviews. LS was assessed via European single question (range 1-10), survivors' QoL via Newsqol (11 dimensions), and caregivers' QoL via Whoqol-bref (4 domains) (range 0-100). Data were analysed using multiple regression models. Two years after stroke onset, 44.7% of patients suffered from impaired sensory function, 35.1% from impaired motor function, and 31.9% from impaired memory function. Mean patient' LS was 7.1/10 (SD 1.9). It was higher in women (+12.4) and lower among unemployed socioeconomically active patients (-13.1, vs. retired people). Adjusted for sex, occupation, impaired motor and memory functions, LS positively correlated with scores of Newsqol feelings, sleep, emotion, cognition and pain dimensions (slopes 0.20 to 0.31), but did not correlate with those of caregivers' Whoqol-bref domains. Family caregiver' LS was 7.2 (SD 1.7). It was lower in those with patients suffering from impaired memory function (-12.8) as well as from feelings and emotion issues (slopes 0.22). It was associated with all caregivers' Whoqol-bref domains (physical health, psychological health, environment, and social relationships) (slopes 0.53 to 0.68). Two-year post-cerebrovascular disease patient' LS was associated with gender, occupation, and impaired memory function. It correlated with feelings, sleep, emotion, cognition, and pain issues. Family caregivers of patients with impaired memory function had lower LS. Family caregiver' LS correlated with dimensions of patients' feelings (less independent, yourself, life changed, depressed, useless, less control because of stroke) and emotion (get more emotional, fear of another stroke or to become dependent on others), and with their own QoL. LS, Newsqol, and Whoqol appeared to be appropriate tools. Our findings may be useful for policy makers in relation to family and medical-social issues of stroke home-based rehabilitation.
Schölvinck, D W; Alvarez Herrero, L; Visser, M; Bergman, J J G H M; Weusten, B L A M
2015-10-01
Preliminary data show higher stricture rates after radiofrequency ablation (RFA) for early esophageal squamous neoplasia compared with Barrett's esophagus. We studied the effects of Lugol stain (LS) directly prior to RFA on stricture formation in squamous epithelium. Of 16 pigs, the distal half of the esophagus was LS, followed by circumferential RFA (single application 12 J/cm(2) ) in the unstained and stained esophagus. Pigs were euthanized at day 0 (n = 4), 3 (n = 4), or 28 (n = 8). Histology was evaluated in four areas: blank-control (no RFA, no LS), blank-RFA (no LS), LS+RFA, and LS-control (no RFA). Stenosis severity in LS+RFA and blank-RFA at 28 days was assessed by the ratio of the mucosal diameter at the RFA area to the diameter 2 cm proximal of this zone. Histology showed submucosal edema in 50% of LS+RFA versus 0% in blank-RFA. Severity and depth of inflammation (day 3) was equal in LS+RFA and blank-RFA. Severity and depth of fibrosis (day 28) appeared more severe in LS+RFA. Consequently, stenosis was present in 100% (LS+RFA) versus 12.5% (blank-RFA). The stenosis-severity ratio was 0.40 (interquartile range 0.29-0.45) in LS+RFA versus 0.73 (interquartile range 0.64-0.78) in blank-RFA (P = 0.012). Limitations of this study were the difference in uptake of LS between pigs and humans, the difference in esophageal anatomy between pigs and humans, and between the proximal and distal esophagus within pigs. In conclusion, in the porcine squamous esophagus, stenosis rate and severity after RFA increased when preceded by LS. LS may be contributing in the altered response of squamous epithelium to RFA as compared with Barrett's esophagus. © 2014 International Society for Diseases of the Esophagus.
Miyata, Hiroaki; Mori, Masaki; Kokudo, Norihiro; Gotoh, Mitsukazu; Konno, Hiroyuki; Wakabayashi, Go; Matsubara, Hisahiro; Watanabe, Toshiaki; Ono, Minoru; Hashimoto, Hideki; Yamamoto, Hiroyuki; Kumamaru, Hiraku; Kohsaka, Shun; Iwanaka, Tadashi
2018-01-01
Objective To assess the use of laparoscopic surgeries (LS) and the association between its performance and hospitals’ preference for LS over open surgeries. Summary background data LS is increasingly used in many abdominal surgeries, albeit both with and without solid guideline recommendations. To date, the hospitals’ preference (LS vs. open surgeries) and its association with in-hospital outcomes has not been evaluated. Methods We enrolled patients undergoing 8 types of gastrointestinal surgeries in 2011–2013 in the Japanese National Clinical Database. We assessed the use of LS and the occurrences of surgery-related morbidity and mortality during the study period. Further, for 4 typical LS procedures, we assessed the hospitals’ preference for LS by modeling the propensity to perform LS (over open surgeries) from patient-level factors, and estimating each institution’s observed/expected (O/E) ratio for LS use. Institutions with O/E>2 were defined as LS-dominant. Using hierarchical logistic regression models, we assessed the association between LS preference and in-hospital outcomes. Results Among 1,377,118 patients undergoing gastrointestinal procedures in 2,336 participating hospitals, use of LS increased in all 8 procedures (35.1% to 44.7% for distal gastrectomy (DG), and 27.5% to 43.2% for right hemi colectomy (RHC)). Those operated at LS-dominant hospitals were at an increased risk of operative death (OR 1.83 [95%CI, 1.37–2.45] for DG, 1.79 [95%CI, 1.43–2.25] for RHC) compared to standard O/E level hospitals (0.5≤O/E<2.0). Conclusions LS use widely increased during 2011–2013 in Japan. Facilities with higher than expected LS use had higher mortality compared to other hospitals, suggesting a need for careful patient selection and dissemination of the procedure. PMID:29505561
Enhancement of lung sounds based on empirical mode decomposition and Fourier transform algorithm.
Mondal, Ashok; Banerjee, Poulami; Somkuwar, Ajay
2017-02-01
There is always heart sound (HS) signal interfering during the recording of lung sound (LS) signals. This obscures the features of LS signals and creates confusion on pathological states, if any, of the lungs. In this work, a new method is proposed for reduction of heart sound interference which is based on empirical mode decomposition (EMD) technique and prediction algorithm. In this approach, first the mixed signal is split into several components in terms of intrinsic mode functions (IMFs). Thereafter, HS-included segments are localized and removed from them. The missing values of the gap thus produced, is predicted by a new Fast Fourier Transform (FFT) based prediction algorithm and the time domain LS signal is reconstructed by taking an inverse FFT of the estimated missing values. The experiments have been conducted on simulated and recorded HS corrupted LS signals at three different flow rates and various SNR levels. The performance of the proposed method is evaluated by qualitative and quantitative analysis of the results. It is found that the proposed method is superior to the baseline method in terms of quantitative and qualitative measurement. The developed method gives better results compared to baseline method for different SNR levels. Our method gives cross correlation index (CCI) of 0.9488, signal to deviation ratio (SDR) of 9.8262, and normalized maximum amplitude error (NMAE) of 26.94 for 0 dB SNR value. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Programmable Infusion Pumps in ICUs: An Analysis of Corresponding Adverse Drug Events
Bower, Anthony G.; Paddock, Susan M.; Hilborne, Lee H.; Wallace, Peggy; Rothschild, Jeffrey M.; Griffin, Anne; Fairbanks, Rollin J.; Carlson, Beverly; Panzer, Robert J.; Brook, Robert H.
2007-01-01
Background Patients in intensive care units (ICUs) frequently experience adverse drug events involving intravenous medications (IV-ADEs), which are often preventable. Objectives To determine how frequently preventable IV-ADEs in ICUs match the safety features of a programmable infusion pump with safety software (“smart pump”) and to suggest potential improvements in smart-pump design. Design Using retrospective medical-record review, we examined preventable IV-ADEs in ICUs before and after 2 hospitals replaced conventional pumps with smart pumps. The smart pumps alerted users when programmed to deliver duplicate infusions or continuous-infusion doses outside hospital-defined ranges. Participants 4,604 critically ill adults at 1 academic and 1 nonacademic hospital. Measurements Preventable IV-ADEs matching smart-pump features and errors involved in preventable IV-ADEs. Results Of 100 preventable IV-ADEs identified, 4 involved errors matching smart-pump features. Two occurred before and 2 after smart-pump implementation. Overall, 29% of preventable IV-ADEs involved overdoses; 37%, failures to monitor for potential problems; and 45%, failures to intervene when problems appeared. Error descriptions suggested that expanding smart pumps’ capabilities might enable them to prevent more IV-ADEs. Conclusion The smart pumps we evaluated are unlikely to reduce preventable IV-ADEs in ICUs because they address only 4% of them. Expanding smart-pump capabilities might prevent more IV-ADEs. PMID:18095043
Chen, Ye; Liu, Jonathan T C
2013-06-01
Dual-axis confocal (DAC) microscopy has been found to exhibit superior rejection of out-of-focus and multiply scattered background light compared to conventional single-axis confocal microscopy. DAC microscopes rely on the use of separated illumination and collection beam paths that focus and intersect at a single focal volume (voxel) within tissue. While it is generally recognized that the resolution and contrast of a DAC microscope depends on both the crossing angle of the DAC beams, 2θ, and the focusing numerical aperture of the individual beams, α, a detailed study to investigate these dependencies has not been performed. Contrast and resolution are considered as two main criteria to assess the performance of a point-scanned DAC microscope (DAC-PS) and a line-scanned DAC microscope (DAC-LS) as a function of θ and α. The contrast and resolution of these designs are evaluated by Monte-Carlo scattering simulations and diffraction theory calculations, respectively. These results can be used for guiding the optimal designs of DAC-PS and DAC-LS microscopes.
New and future heat pump technologies
NASA Astrophysics Data System (ADS)
Creswick, F. A.
It is not possible to say for sure what future heat pumps will look like, but there are some interesting possibilities. In the next five years, we are likely to see US heat pumps with two kinds of innovations: capacity modulation and charge control. Capacity modulation will be accomplished by variable-speed compressor motors. The objective of charge control is to keep the refrigerant charge in the system where it belongs for best performance; there are probably many ways to accomplish this. Charge control will improve efficiency and durability; capacity modulation will further improve efficiency and comfort. The Stirling cycle heat pump has several interesting advantages, but it is farther out in time. At present, we don't know how to make it as efficient as the conventional vapor-compression heat pump. Electric utility people should be aware that major advances are being made in gas-fired heat pumps which could provide strong competition in the future. However, even a gas-fired heat pump has a substantial auxiliary electric power requirement. The resources needed to develop advanced heat pumps are substantial and foreign competition will be intense. It will be important for utilities, manufacturers, and the federal government to work in close cooperation.
Kim, Myung Hwa; Shim, Yon Hee; Kim, Min-Soo; Shin, Yang-Sik; Lee, Hyun Joo; Lee, Jeong Soo
2017-01-01
When considering the principles of a pain control strategy by patients, reliable administration of additional bolus doses is important for providing the adequate analgesia and improving patient satisfaction. We compared the efficacy of elastomeric patient-control module (PCM) with conventional PCM providing epidural analgesia postoperatively.A noninferiority comparison was used. Eighty-six patients scheduled for open upper abdominal surgery were randomized to use either an elastomeric or conventional PCM connected to balloon pump. After successful epidural catheter insertion at T6-8 level, fentanyl (15-20 μg/kg) in 0.3% ropivacaine 100 mL was administered at basal rate 2 mL/h with bolus 2 mL and lock-out time 15 minutes. The primary outcome was the verbal numerical rating score for pain.The 95% confidence intervals for differences in pain scores during the first 48 hours postoperatively were <1, indicating noninferiority of the elastomeric PCM. The duration of pump reservoir exhaustion was shorter for the elastomeric PCM (mean [SD], 33 hours [8 hours] vs 40 hours [8 hours], P = 0.0003). There were no differences in the frequency of PCM use, additional analgesics, or adverse events between groups.The elastomeric PCM was as effective as conventional PCM with and exhibited a similar safety profile.
NASA Astrophysics Data System (ADS)
Ahrns, Johannes; Bartak, Rico; Grischek, Thomas; Pörschke, Richard
2017-11-01
In subsurface iron removal (SIR), oxygen-enriched water is injected into an aquifer to create a reaction zone. Aside from the hydraulic properties of the aquifer, groundwater quality often varies with depth so that in vertical wells the dissolved oxygen distribution (reaction zone) may not correspond to the dissolved iron concentration which may result in a lower efficiency coefficient. Therefore, measures to hydraulically optimize the formation of the reaction zone through a non-conventional injection were investigated. A high-resolution groundwater flow model was calibrated based on tracer and pump tests and used to plan the optimized injection for a SIR-pilot well with two screen segments. An optimized injection appears to be possible through the inactivation of well screen sections using packers. A doubling of the efficiency coefficient in comparison to a conventional injection was predicted when a packer, which remains evacuated inside the well while pumping, was used to seal 4/5 of the upper well screen length during injection. This scenario was used to plan the operating regime for a SIR field test, which is presented in Part 2.
An exciton-polariton laser based on biologically produced fluorescent protein
Dietrich, Christof P.; Steude, Anja; Tropf, Laura; Schubert, Marcel; Kronenberg, Nils M.; Ostermann, Kai; Höfling, Sven; Gather, Malte C.
2016-01-01
Under adequate conditions, cavity polaritons form a macroscopic coherent quantum state, known as polariton condensate. Compared to Wannier-Mott excitons in inorganic semiconductors, the localized Frenkel excitons in organic emitter materials show weaker interaction with each other but stronger coupling to light, which recently enabled the first realization of a polariton condensate at room temperature. However, this required ultrafast optical pumping, which limits the applications of organic polariton condensates. We demonstrate room temperature polariton condensates of cavity polaritons in simple laminated microcavities filled with biologically produced enhanced green fluorescent protein (eGFP). The unique molecular structure of eGFP prevents exciton annihilation even at high excitation densities, thus facilitating polariton condensation under conventional nanosecond pumping. Condensation is clearly evidenced by a distinct threshold, an interaction-induced blueshift of the condensate, long-range coherence, and the presence of a second threshold at higher excitation density that is associated with the onset of photon lasing. PMID:27551686
Highly efficient generation of broadband cascaded four-wave mixing products.
Cerqueira S, Arismar; Boggio, J M Chavez; Rieznik, A A; Hernandez-Figueroa, H E; Fragnito, H L; Knight, J C
2008-02-18
We propose a novel way to efficiently generate broadband cascaded Four-Wave Mixing (FWM) products. It consists of launching two strong pump waves near the zero-dispersion wavelength of a very short (of order a few meters) optical fiber. Simulations based on Split Step Fourier Method (SSFM) and experimental data demonstrate the efficiency of our new approach. Multiple FWM products have been investigated by using conventional fibers and ultra-flattened dispersion photonic crystal fibers (UFD-PCFs). Measured results present bandwidths of 300 nm with up to 118 FWM products. We have also demonstrated a flat bandwidth of 110 nm covering the C and L bands, with a small variation of only 1.2 dB between the powers of FWM products, has been achieved using highly nonlinear fibers (HNLFs). The use of UFD-PCFs has been shown interesting for improving the multiple FWM efficiency and reducing the separation between the pump wavelengths.
Irrigation market for solar thermal parabolic dish systems
NASA Technical Reports Server (NTRS)
Habib-Agahi, H.; Jones, S. C.
1981-01-01
The potential size of the onfarm-pumped irrigation market for solar thermal parabolic dish systems in seven high-insolation states is estimated. The study is restricted to the displacement of three specific fuels: gasoline, diesel and natural gas. The model was developed to estimate the optimal number of parabolic dish modules per farm based on the minimum cost mix of conventional and solar thermal energy required to meet irrigation needs. The study concludes that the potential market size for onfarm-pumped irrigation applications ranges from 101,000 modules when a 14 percent real discount rate is assumed to 220,000 modules when the real discount rate drops to 8 percent. Arizona, Kansas, Nebraska, New Mexico and Texas account for 98 percent of the total demand for this application, with the natural gas replacement market accounting for the largest segment (71 percent) of the total market.
NASA Astrophysics Data System (ADS)
Tian, Ying; Jing, Xufeng; Xu, Shiqing
2013-11-01
Intense 2.0 μm emission has been obtained in Ho3+/Tm3+ codoped ZBLAY glass pumped by common laser diode. Three intensity parameters and radiative properties have been determined from the absorption spectrum based on the Judd-Ofelt theory. The 2 μm emission characteristics and the energy transfer mechanism upon excitation of a conventional 800 nm laser diode are investigated. Efficient Tm3+ to Ho3+ energy transfer processes have been observed in present glass and investigated using steady-state and time-resolved optical spectroscopy measurement. The energy transfer microscopic parameter has been calculated with the Inokuti-Hirayama and Förster-Dexter models. High quantum efficiency of 2 μm emission (80.35%) and large energy transfer coefficient from Tm3+ to Ho3+ indicates this Ho3+/Tm3+ codoped ZBLAY glass is a promising material for 2.0 μm laser.
Chihi, Asma; Ben Azza, Hechmi; Jemli, Mohamed; Sellami, Anis
2017-09-01
The aim of this paper is to provide high performance control of pumping system. The proposed method is designed by an indirect field oriented control based on Sliding Mode (SM) technique. The first contribution of this work is to design modified switching surfaces which presented by adding an integral action to the considered controlled variables. Then, in order to prevent the chattering phenomenon, modified nonlinear component is developed. The SM concept and a Lyapunov function are combined to compute the Sliding Mode Control (SMC) gains. Besides, the motor performance is validated by numeric simulations and real time implementation using a dSpace system with DS1104 controller board. Also, to show the effectiveness of the proposed approach, the obtained results are compared with other techniques such as conventional PI, Proportional Sliding Mode (PSM) and backstepping controls. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
MODFLOW equipped with a new method for the accurate simulation of axisymmetric flow
NASA Astrophysics Data System (ADS)
Samani, N.; Kompani-Zare, M.; Barry, D. A.
2004-01-01
Axisymmetric flow to a well is an important topic of groundwater hydraulics, the simulation of which depends on accurate computation of head gradients. Groundwater numerical models with conventional rectilinear grid geometry such as MODFLOW (in contrast to analytical models) generally have not been used to simulate aquifer test results at a pumping well because they are not designed or expected to closely simulate the head gradient near the well. A scaling method is proposed based on mapping the governing flow equation from cylindrical to Cartesian coordinates, and vice versa. A set of relationships and scales is derived to implement the conversion. The proposed scaling method is then embedded in MODFLOW 2000. To verify the accuracy of the method steady and unsteady flows in confined and unconfined aquifers with fully or partially penetrating pumping wells are simulated and compared with the corresponding analytical solutions. In all cases a high degree of accuracy is achieved.
Nakamura, Misa; Hashizume, Hiroshi; Oka, Hiroyuki; Okada, Morihiro; Takakura, Rie; Hisari, Ayako; Yoshida, Munehito; Utsunomiya, Hirotoshi
2015-01-01
The Japanese Orthopaedic Association proposed a concept called locomotive syndrome (LS) to identify middle-aged and older adults at high risk of requiring health care services because of problems with locomotion. It is important to identify factors associated with the development of LS. Physical performance measures such as walking speed and standing balance are highly predictive of subsequent disability and mortality in older adults. However, there is little evidence about the relationship between physical performance measures and LS. To determine the physical performance measures associated with LS, the threshold values for discriminating individuals with and without LS, and the odds ratio of LS according to performance greater than or less than these thresholds in middle-aged and older Japanese women. Participants were 126 Japanese women (mean age = 61.8 years). Locomotive syndrome was defined as a score of 16 or more on the 25-question Geriatric Locomotive Function Scale. Physical performance was evaluated using grip strength, unipedal stance time with eyes open, seated toe-touch, and normal and fast 6-m walk time (6 MWT). Variables were compared between LS and non-LS groups. Fourteen participants (11.1%) were classed as having LS. Unipedal stance time, normal 6 MWT, and fast 6 MWT were significantly different between the 2 groups. The LS group had a shorter unipedal stance time and a longer normal and fast 6 MWT than the non-LS group. For these 3 variables, the area under the receiver operating characteristic curve was greater than 0.7, and the threshold for discriminating the non-LS and LS groups was 15 s for unipedal stance time, 4.8 s for normal 6 MWT and 3.6 s for fast 6 MWT. These variables were entered into a multiple logistic regression analysis, which indicated that unipedal stance time less than 15 s was significantly related to LS (odds ratio = 8.46; P < .01). Unipedal stance time was the physical performance measure that was most strongly associated with LS. This measure may be useful for early detection of LS.
Adapting Logistics Models to a Microcomputer for Interface with Computer-Aided Design Systems.
1984-09-01
32654 32654 32654 32654 32654 1 LS AFRRF2 -1 32654 32654 32654 32654 32654 1 LS AFRDII -1 32654 32654 32654 32654 32654 1 LS AFRDI2 -1 32654 ... 32654 32654 32654 32654 1 LS AFRMEI -1 32654 32654 32654 32654 32654 1 LS AFRME2 -1 32654 32654 32654 32654 32654 1
Apical membrane permeability and kinetic properties of the sodium pump in rabbit urinary bladder.
Lewis, S A; Wills, N K
1983-08-01
Previous studies have shown that aldosterone stimulates the rate of Na+ transport across the rabbit urinary bladder epithelium by increasing the apical membrane permeability to Na+. Paradoxically, ion-sensitive and conventional micro-electrode measurements demonstrated that intracellular Na+ activity aiNa+ was essentially unchanged by aldosterone, i.e. aiNa+ was constant regardless of the rate of Na+ transport. The present study was designed to resolve this apparent contradiction. The effects of elevated, endogenous aldosterone levels produced by low-Na+ diet (Lewis & Diamond, 1976) on urinary bladder Na+ transport were investigated in vitro using Ussing-type chambers and intracellular conventional and ion-sensitive microelectrodes. Apical membrane selectivity and kinetics of the Na+ pump were assessed as a function of hormone stimulation. The aldosterone-stimulated increase in Na+ transport was accounted for by increases in both the relative selective permeability of the apical membrane to Na+ and an increase in its absolute Na+ permeability. The kinetics of the Na+ pump were evaluated electrically by loading the cells with Na+ (monitored with Na+-sensitive micro-electrodes) or alternatively by manipulating serosal solution K+ concentration and measuring changes in the basolateral membrane electromotive forces and resistance. From these measurements the current generated by the pump was calculated as a function of intracellular Na+ or extracellular K+. The kinetics of the pump were not altered by aldosterone. A model of highly co-operative binding estimated Km for Na+ as 14.2 mM and 2.3 mM for K+. Hill coefficients for these ions were 2.8 and 1.8, respectively, consistent with a pump stoichiometry of 3 Na+ to 2 K+. The kinetic properties of the Na-K pump indicate that physiological levels of aiNa+ are poised at the foot of a step kinetic curve which energetically favours Na+ extrusion.
Liu, Pei; Wang, Sicong; He, Puyuan; Zhang, Zhaowei
2018-05-01
We report, to the best of our knowledge, a novel approach for generating broadband mid-infrared (mid-IR) light by implementing a dual-channel scheme in a synchronously pumped optical parametric oscillator (SPOPO). Two-channel operation was achieved by inserting a prism pair and two reflection mirrors inside an optical parametric oscillator (OPO) cavity. Pumped by a Yb-fiber laser, the OPO generated an idler wave at ∼3150 nm with a -10 dB bandwidth of ∼13.2 THz, which was twice as much as that of the pump source. This scheme represents a promising technical route to transform conventional SPOPOs into a device capable of generating mid-IR light with very broad instantaneous bandwidth.
Spin accumulation in permalloy-ZnO heterostructures from both electrical injection and spin pumping
NASA Astrophysics Data System (ADS)
Wang, Xiaowei; Yang, Yumeng; Wang, Ying; Luo, Ziyan; Xie, Hang; Wu, Yihong
2017-11-01
We report the results of room temperature spin injection and detection studies in ZnO using both electrical injection and spin pumping. At ferromagnetic resonance, an interfacial voltage with a constant polarity upon magnetization reversal is observed in permalloy-ZnO heterostructures, which is attributed to spin accumulation after ruling out other origins. Simultaneous electrical injection during spin pumping is achieved in samples with large interface resistance or insertion of a thin MgO layer at the interface of permalloy and ZnO. From the pumping frequency dependence of detected voltage, a spin lifetime of 32 ps is extracted for ZnO at room temperature, despite the fact that there was no Hanle effect observed in the same device using the conventional three-terminal DC measurement.
Genetic analyses of stillbirth in relation to litter size using random regression models.
Chen, C Y; Misztal, I; Tsuruta, S; Herring, W O; Holl, J; Culbertson, M
2010-12-01
Estimates of genetic parameters for number of stillborns (NSB) in relation to litter size (LS) were obtained with random regression models (RRM). Data were collected from 4 purebred Duroc nucleus farms between 2004 and 2008. Two data sets with 6,575 litters for the first parity (P1) and 6,259 litters for the second to fifth parity (P2-5) with a total of 8,217 and 5,066 animals in the pedigree were analyzed separately. Number of stillborns was studied as a trait on sow level. Fixed effects were contemporary groups (farm-year-season) and fixed cubic regression coefficients on LS with Legendre polynomials. Models for P2-5 included the fixed effect of parity. Random effects were additive genetic effects for both data sets with permanent environmental effects included for P2-5. Random effects modeled with Legendre polynomials (RRM-L), linear splines (RRM-S), and degree 0 B-splines (RRM-BS) with regressions on LS were used. For P1, the order of polynomial, the number of knots, and the number of intervals used for respective models were quadratic, 3, and 3, respectively. For P2-5, the same parameters were linear, 2, and 2, respectively. Heterogeneous residual variances were considered in the models. For P1, estimates of heritability were 12 to 15%, 5 to 6%, and 6 to 7% in LS 5, 9, and 13, respectively. For P2-5, estimates were 15 to 17%, 4 to 5%, and 4 to 6% in LS 6, 9, and 12, respectively. For P1, average estimates of genetic correlations between LS 5 to 9, 5 to 13, and 9 to 13 were 0.53, -0.29, and 0.65, respectively. For P2-5, same estimates averaged for RRM-L and RRM-S were 0.75, -0.21, and 0.50, respectively. For RRM-BS with 2 intervals, the correlation was 0.66 between LS 5 to 7 and 8 to 13. Parameters obtained by 3 RRM revealed the nonlinear relationship between additive genetic effect of NSB and the environmental deviation of LS. The negative correlations between the 2 extreme LS might possibly indicate different genetic bases on incidence of stillbirth.
DOE Office of Scientific and Technical Information (OSTI.GOV)
A. Poerschke, R. Beach, T. Begg
IBACOS investigated the performance of a small-diameter high-velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance.
Advanced Optical Fibers for High power Fiber lasers
2015-08-24
crystal fiber cladding . Advanced Optical Fibers for High Power Fiber Lasers http://dx.doi.org/10.5772/58958 223 lengths above the second-order mode cut...brightness multimode diode lasers for a given pump waveguide dimen‐ sion. In conventional double- clad fibers, low-index polymer coatings are typically used to...was below 0.2. The fiber was passive and there was no laser demonstration in this first attempt. The first cladding - pumping demonstration in an
Luminescent threat: toxicity of light stick attractors used in pelagic fishery
de Oliveira, Tiago Franco; da Silva, Amanda Lucila Medeiros; de Moura, Rafaela Alves; Bagattini, Raquel; de Oliveira, Antonio Anax Falcão; de Medeiros, Marisa Helena Gennari; Di Mascio, Paolo; de Arruda Campos, Ivan Pérsio; Barretto, Fabiano Prado; Bechara, Etelvino José Henriques; de Melo Loureiro, Ana Paula
2014-01-01
Light sticks (LS) are sources of chemiluminescence commonly used in pelagic fishery, where hundreds are discarded and reach the shores. Residents from fishing villages report an improper use of LS contents on the skin. Given the scarce information regarding LS toxicity, the effects of LS solutions in cell cultures were evaluated herein. Loss of viability, cell cycle changes and DNA fragmentation were observed in HepG2 cell line and skin fibroblasts. A non-cytotoxic LS concentration increased the occurrence of the mutagenic lesion 1,N6-εdAdo in HepG2 DNA by three-fold. Additionally, in vitro incubations of spent LS contents with DNA generated dGuo-LS adducts, whose structure elucidation revealed the presence of a reactive chlorinated product. In conclusion, the LS contents were found to be highly cyto- and genotoxic. Our data indicate an urgent need for LS waste management guidelines and for adequate information regarding toxic outcomes that may arise from human exposure. PMID:24942522
Novel Hybrid of LS-SVM and Kalman Filter for GPS/INS Integration
NASA Astrophysics Data System (ADS)
Xu, Zhenkai; Li, Yong; Rizos, Chris; Xu, Xiaosu
Integration of Global Positioning System (GPS) and Inertial Navigation System (INS) technologies can overcome the drawbacks of the individual systems. One of the advantages is that the integrated solution can provide continuous navigation capability even during GPS outages. However, bridging the GPS outages is still a challenge when Micro-Electro-Mechanical System (MEMS) inertial sensors are used. Methods being currently explored by the research community include applying vehicle motion constraints, optimal smoother, and artificial intelligence (AI) techniques. In the research area of AI, the neural network (NN) approach has been extensively utilised up to the present. In an NN-based integrated system, a Kalman filter (KF) estimates position, velocity and attitude errors, as well as the inertial sensor errors, to output navigation solutions while GPS signals are available. At the same time, an NN is trained to map the vehicle dynamics with corresponding KF states, and to correct INS measurements when GPS measurements are unavailable. To achieve good performance it is critical to select suitable quality and an optimal number of samples for the NN. This is sometimes too rigorous a requirement which limits real world application of NN-based methods.The support vector machine (SVM) approach is based on the structural risk minimisation principle, instead of the minimised empirical error principle that is commonly implemented in an NN. The SVM can avoid local minimisation and over-fitting problems in an NN, and therefore potentially can achieve a higher level of global performance. This paper focuses on the least squares support vector machine (LS-SVM), which can solve highly nonlinear and noisy black-box modelling problems. This paper explores the application of the LS-SVM to aid the GPS/INS integrated system, especially during GPS outages. The paper describes the principles of the LS-SVM and of the KF hybrid method, and introduces the LS-SVM regression algorithm. Field test data is processed to evaluate the performance of the proposed approach.