Wong, M S; Cheng, J C Y; Wong, M W; So, S F
2005-04-01
A study was conducted to compare the CAD/CAM method with the conventional manual method in fabrication of spinal orthoses for patients with adolescent idiopathic scoliosis. Ten subjects were recruited for this study. Efficiency analyses of the two methods were performed from cast filling/ digitization process to completion of cast/image rectification. The dimensional changes of the casts/ models rectified by the two cast rectification methods were also investigated. The results demonstrated that the CAD/CAM method was faster than the conventional manual method in the studied processes. The mean rectification time of the CAD/CAM method was shorter than that of the conventional manual method by 108.3 min (63.5%). This indicated that the CAD/CAM method took about 1/3 of the time of the conventional manual to finish cast rectification. In the comparison of cast/image dimensional differences between the conventional manual method and the CAD/CAM method, five major dimensions in each of the five rectified regions namely the axilla, thoracic, lumbar, abdominal and pelvic regions were involved. There were no significant dimensional differences (p < 0.05) in 19 out of the 25 studied dimensions. This study demonstrated that the CAD/CAM system could save the time in the rectification process and offer a relatively high resemblance in cast rectification as compared with the conventional manual method.
Wong, M S; Cheng, C Y; Ng, B K W; Lam, T P; Chiu, S W
2006-01-01
Spinal orthoses are commonly prescribed to patients with moderate AIS for prevention of further deterioration. In a conventional manufacturing method, plaster bandages are used to get patient's body contour and plaster cast is rectified manually. With the introduction of CAD/CAM system, a series of automated processes from body scanning to digital rectification and milling of positive model can be performed in a fast and accurate fashion. This project is to study the impact of CAD/CAM method as compared with the conventional method. In assessing the 147 recruited subjects fitted with spinal orthoses (43 subjects using conventional method and 104 subjects using CAD/CAM method), significant decreases (p<0.05) were found in the Cobb angles when comparing the pre-intervention data with that of the first year of intervention. Regarding the learning curve, Orthotists are getting more competent with the CAD/CAM technique in four years time. The mean productivity of the CAD/CAM method is 2.75 times higher than that of the conventional method. The CAD/CAM method could achieve similar clinical outcomes and with its high efficiency, could be considered as substitute for conventional methods in fabricating spinal orthoses for patients with AIS.
Li, Xiaohui; Yu, Jianhua; Gong, Yuekun; Ren, Kaijing; Liu, Jun
2015-04-21
To assess the early postoperative clinical and radiographic outcomes after navigation-assisted or standard instrumentation total knee arthroplasty (TKA). From August 2007 to May 2008, 60 KSS-A type patients underwent 67 primary TKA operations by the same surgical team. Twenty-two operations were performed with the Image-free navigation system with an average age of 64.5 years while the remaining 45 underwent conventional manual procedures with an average age of 66 years. Their preoperative demographic and functional data had no statistical differences (P>0.05). The operative duration, blood loss volume and hospitalization days were compared for two groups. And radiographic data included coronal femoral component angle, coronal tibial component angle, sagittal femoral component angle, sagittal tibial component angle and coronal tibiofemoral angle after one month. And functional assessment scores were evaluated at 1, 3 and 6 months postoperatively. Operative duration was significantly longer for computer navigation (P<0.05). The average blood loss volume was 555.26 ml in computer navigation group and 647.56 ml in conventional manual method group (P<0.05). And hospitalization stay was shorter in computer navigation group than that in conventional method group (7.74 vs 8.68 days) (P=0.04). The alignment deviation was better in computer-assisted group than that in conventional manual method group (P<0.05). The percentage of patients with a coronal tibiofemoral angle within ±3 of ideal value was 95.45% for computer-assisted mini-invasive TKA group and 80% for conventional TKA group (P=0.003). The Knee Society Clinical Rating Score was higher in computer-assisted group than that in conventional manual method group at 1 and 3 montha post-operation. However, no statistical inter-group difference existed at 6 months post-operation. Navigation allows a surgeon to precisely implant the components for TKA. And it offers faster functional recovery and shorter hospitalization stay. At 6 months post-operation, there is no statistical inter-group difference in KSS scores.
Manual tracing versus smartphone application (app) tracing: a comparative study.
Sayar, Gülşilay; Kilinc, Delal Dara
2017-11-01
This study aimed to compare the results of conventional manual cephalometric tracing with those acquired with smartphone application cephalometric tracing. The cephalometric radiographs of 55 patients (25 females and 30 males) were traced via the manual and app methods and were subsequently examined with Steiner's analysis. Five skeletal measurements, five dental measurements and two soft tissue measurements were managed based on 21 landmarks. The durations of the performances of the two methods were also compared. SNA (Sella, Nasion, A point angle) and SNB (Sella, Nasion, B point angle) values for the manual method were statistically lower (p < .001) than those for the app method. The ANB value for the manual method was statistically lower than that of app method. L1-NB (°) and upper lip protrusion values for the manual method were statistically higher than those for the app method. Go-GN/SN, U1-NA (°) and U1-NA (mm) values for manual method were statistically lower than those for the app method. No differences between the two methods were found in the L1-NB (mm), occlusal plane to SN, interincisal angle or lower lip protrusion values. Although statistically significant differences were found between the two methods, the cephalometric tracing proceeded faster with the app method than with the manual method.
Wei, L; Chen, H; Zhou, Y S; Sun, Y C; Pan, S X
2017-02-18
To compare the technician fabrication time and clinical working time of custom trays fabricated using two different methods, the three-dimensional printing custom trays and the conventional custom trays, and to prove the feasibility of the computer-aided design/computer-aided manufacturing (CAD/CAM) custom trays in clinical use from the perspective of clinical time cost. Twenty edentulous patients were recruited into this study, which was prospective, single blind, randomized self-control clinical trials. Two custom trays were fabricated for each participant. One of the custom trays was fabricated using functional suitable denture (FSD) system through CAD/CAM process, and the other was manually fabricated using conventional methods. Then the final impressions were taken using both the custom trays, followed by utilizing the final impression to fabricate complete dentures respectively. The technician production time of the custom trays and the clinical working time of taking the final impression was recorded. The average time spent on fabricating the three-dimensional printing custom trays using FSD system and fabricating the conventional custom trays manually were (28.6±2.9) min and (31.1±5.7) min, respectively. The average time spent on making the final impression with the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually were (23.4±11.5) min and (25.4±13.0) min, respectively. There was significant difference in the technician fabrication time and the clinical working time between the three-dimensional printing custom trays using FSD system and the conventional custom trays fabricated manually (P<0.05). The average time spent on fabricating three-dimensional printing custom trays using FSD system and making the final impression with the trays are less than those of the conventional custom trays fabricated manually, which reveals that the FSD three-dimensional printing custom trays is less time-consuming both in the clinical and laboratory process than the conventional custom trays. In addition, when we manufacture custom trays by three-dimensional printing method, there is no need to pour preliminary cast after taking the primary impression, therefore, it can save the impression material and model material. As to completing denture restoration, manufacturing custom trays using FSD system is worth being popularized.
Wong, M S; Cheng, J C Y; Lo, K H
2005-04-01
The treatment effectiveness of the CAD/CAM method and the manual method in managing adolescent idiopathic scoliosis (AIS) was compared. Forty subjects were recruited with twenty subjects for each method. The clinical parameters namely Cobb's angle and apical vertebral rotation were evaluated at the pre-brace and the immediate in-brace visits. The results demonstrated that orthotic treatments rendered by the CAD/CAM method and the conventional manual method were effective in providing initial control of Cobb's angle. Significant decreases (p < 0.05) were found between the pre-brace and immediate in-brace visits for both methods. The mean reductions of Cobb's angle were 12.8 degrees (41.9%) for the CAD/CAM method and 9.8 degrees (32.1%) for the manual method. An initial control of the apical vertebral rotation was not shown in this study. In the comparison between the CAD/CAM method and the manual method, no significant difference was found in the control of Cobb's angle and apical vertebral rotation. The current study demonstrated that the CAD/CAM method can provide similar result in the initial stage of treatment as compared with the manual method.
Vrooman, Henri A; Cocosco, Chris A; van der Lijn, Fedde; Stokking, Rik; Ikram, M Arfan; Vernooij, Meike W; Breteler, Monique M B; Niessen, Wiro J
2007-08-01
Conventional k-Nearest-Neighbor (kNN) classification, which has been successfully applied to classify brain tissue in MR data, requires training on manually labeled subjects. This manual labeling is a laborious and time-consuming procedure. In this work, a new fully automated brain tissue classification procedure is presented, in which kNN training is automated. This is achieved by non-rigidly registering the MR data with a tissue probability atlas to automatically select training samples, followed by a post-processing step to keep the most reliable samples. The accuracy of the new method was compared to rigid registration-based training and to conventional kNN-based segmentation using training on manually labeled subjects for segmenting gray matter (GM), white matter (WM) and cerebrospinal fluid (CSF) in 12 data sets. Furthermore, for all classification methods, the performance was assessed when varying the free parameters. Finally, the robustness of the fully automated procedure was evaluated on 59 subjects. The automated training method using non-rigid registration with a tissue probability atlas was significantly more accurate than rigid registration. For both automated training using non-rigid registration and for the manually trained kNN classifier, the difference with the manual labeling by observers was not significantly larger than inter-observer variability for all tissue types. From the robustness study, it was clear that, given an appropriate brain atlas and optimal parameters, our new fully automated, non-rigid registration-based method gives accurate and robust segmentation results. A similarity index was used for comparison with manually trained kNN. The similarity indices were 0.93, 0.92 and 0.92, for CSF, GM and WM, respectively. It can be concluded that our fully automated method using non-rigid registration may replace manual segmentation, and thus that automated brain tissue segmentation without laborious manual training is feasible.
Gillard, Montgomery; Wang, Timothy S; Boyd, Charles M; Dunn, Rodney L; Fader, Darrell J; Johnson, Timothy M
2002-08-01
To directly compare cosmetic improvement and postoperative sequelae resulting from dermabrasion of surgical scars with conventional motor-powered diamond fraise vs manual dermabrasion with medium-grade drywall sanding screen. Patients were randomly assigned to receive treatment with conventional diamond fraise dermabrasion to one half of the scar and manual dermabrasion with a drywall sanding screen to the other half in a prospective, comparative clinical study. Blinded observers assessed clinical variables during a 6-month follow-up period. University hospital/cancer center-based cutaneous surgery unit. Twenty-one healthy volunteers, Fitzpatrick skin type I to III, with contour irregularities resulting from granulation (7 patients) or reconstruction (14 patients) after skin cancer excision. One half of the patient's scar was treated with motor-powered diamond fraise dermabrasion and the other half was treated with manual dermabrasion with medium-grade drywall sanding screen. Correction of contour, scarline visibility, time to reepithelialization, presence or absence of milia, degree of postoperative erythema, hypertrophic scarring, patients' subjective reports of postoperative pain, and presence of pigmentary changes were observed for both methods. Standardized scoring systems were used to quantify outcome measures. According to the standardized scoring systems, no differences were found between the 2 methods at any point. In addition, no significant differences were found between the methods for any measure at any of the time points. Both dermabrasion techniques are equally effective in improving the cosmetic appearance of surgical scars.
Comparative study of Sperm Motility Analysis System and conventional microscopic semen analysis
KOMORI, KAZUHIKO; ISHIJIMA, SUMIO; TANJAPATKUL, PHANU; FUJITA, KAZUTOSHI; MATSUOKA, YASUHIRO; TAKAO, TETSUYA; MIYAGAWA, YASUSHI; TAKADA, SHINGO; OKUYAMA, AKIHIKO
2006-01-01
Background and Aim: Conventional manual sperm analysis still shows variations in structure, process and outcome although World Health Organization (WHO) guidelines present an appropriate method for sperm analysis. In the present study a new system for sperm analysis, Sperm Motility Analysis System (SMAS), was compared with manual semen analysis based on WHO guidelines. Materials and methods: Samples from 30 infertility patients and 21 healthy volunteers were subjected to manual microscopic analysis and SMAS analysis, simultaneously. We compared these two methods with respect to sperm concentration and percent motility. Results: Sperm concentrations obtained by SMAS (Csmas) and manual microscopic analyses on WHO guidelines (Cwho) were strongly correlated (Cwho = 1.325 × Csmas; r = 0.95, P < 0.001). If we excluded subjects with Csmas values >30 × 106 sperm/mL, the results were more similar (Cwho = 1.022 × Csmas; r = 0.81, P < 0.001). Percent motility obtained by SMAS (Msmas) and manual analysis on WHO guidelines (Mwho) were strongly correlated (Mwho = 1.214 × Msmas; r = 0.89, P < 0.001). Conclusions: The data indicate that the results of SMAS and those of manual microscopic sperm analyses based on WHO guidelines are strongly correlated. SMAS is therefore a promising system for sperm analysis. (Reprod Med Biol 2006; 5: 195–200) PMID:29662398
Otero, Carles; Aldaba, Mikel; López, Silvia; Díaz-Doutón, Fernando; Vera-Díaz, Fuensanta A; Pujol, Jaume
2018-06-01
To study the accommodative dynamics for predictable and unpredictable stimuli using manual and automated accommodative facility tests Materials and Methods: Seventeen young healthy subjects were tested monocularly in two consecutive sessions, using five different conditions. Two conditions replicated the conventional monocular accommodative facility tests for far and near distances, performed with manually held flippers. The other three conditions were automated and conducted using an electro-optical system and open-field autorefractor. Two of the three automated conditions replicated the predictable manual accommodative facility tests. The last automated condition was a hybrid approach using a novel method whereby far and near-accommodative-facility tests were randomly integrated into a single test of four unpredictable accommodative demands. The within-subject standard deviations for far- and near-distance-accommodative reversals were (±1,±1) cycles per minute (cpm) for the manual flipper accommodative facility conditions and (±3, ±4) cpm for the automated conditions. The 95% limits of agreement between the manual and the automated conditions for far and near distances were poor: (-18, 12) and (-15, 3). During the hybrid unpredictable condition, the response time and accommodative response parameters were significantly (p < 0.05) larger for accommodation than disaccommodation responses for high accommodative demands only. The response times during the transitions 0.17/2.17 D and 0.50/4.50 D appeared to be indistinguishable between the hybrid unpredictable and the conventional predictable automated tests. The automated accommodative facility test does not agree with the manual flipper test results. Operator delays in flipping the lens may account for these differences. This novel test, using unpredictable stimuli, provides a more comprehensive examination of accommodative dynamics than conventional manual accommodative facility tests. Unexpectedly, the unpredictability of the stimulus did not to affect accommodation dynamics. Further studies are needed to evaluate the sensitivity of this novel hybrid technique on individuals with accommodative anomalies.
Manual Therapy Practices of Sobadores in North Carolina
Graham, Alan; Sandberg, Joanne C.; Quandt, Sara A.; Mora, Dana C.
2016-01-01
Abstract Objectives: This analysis provides a description of the manual-therapy elements of sobadores practicing in North Carolina, using videotapes of patient treatment sessions. Design: Three sobadores allowed the video recording of eight patient treatment sessions (one each for two sobadores, six for the third sobador). Each of the recordings was reviewed by an experienced chiropractor who recorded the frequencies of seven defined manual-therapy elements: (1) treatment time; (2) patient position on treatment surface; (3) patient body part contacted by the sobador; (4) sobador examination methods; (5) primary treatment processes; (6) sobador body part area referencing patient; and (7) adjunctive treatment processes. Results: The range of treatment time of 9–30 min was similar to the treatment spectra that combine techniques used by conventional massage and manipulative practitioners. The patient positions on the treatment surface were not extraordinary, given the wide variety of treatment processes used, and indicated the sobadores treat patients in multiple positions. The patient body part contacted by the sobadores indicated that they were treating each of the major parts of the musculoskeletal system. Basic palpation dominated the sobadores' examination methods. The sobadores' primary treatment processes included significant variety, but rubbing was the dominant practice. The hands were the sobador body area that most often made contact with the patient. They all used lubricants. Conclusions: Sobadores' methods are similar to those of other manual-therapy practitioners. Additional study of video-recorded sobador practices is needed. Video-recorded practice of other traditional and conventional manual therapies for comparative analysis will help delineate the specific similarities and differences among the manual therapies. PMID:27400120
Zhen, Chen; QuiuLi, Zhang; YuanQi, An; Casado, Verónica Vocero; Fan, Yuan
2016-01-01
Currently, conventional enzyme immunoassays which use manual gold immunoassays and colloidal tests (GICTs) are used as screening tools to detect Treponema pallidum (syphilis), hepatitis B virus (HBV), hepatitis C virus (HCV), human immunodeficiency virus type 1 (HIV-1), and HIV-2 in patients undergoing surgery. The present observational, cross-sectional study compared the sensitivity, specificity, and work flow characteristics of the conventional algorithm with manual GICTs with those of a newly proposed algorithm that uses the automated Bio-Flash technology as a screening tool in patients undergoing gastrointestinal (GI) endoscopy. A total of 956 patients were examined for the presence of serological markers of infection with HIV-1/2, HCV, HBV, and T. pallidum. The proposed algorithm with the Bio-Flash technology was superior for the detection of all markers (100.0% sensitivity and specificity for detection of anti-HIV and anti-HCV antibodies, HBV surface antigen [HBsAg], and T. pallidum) compared with the conventional algorithm based on the manual method (80.0% sensitivity and 98.6% specificity for the detection of anti-HIV, 75.0% sensitivity for the detection of anti-HCV, 94.7% sensitivity for the detection of HBsAg, and 100% specificity for the detection of anti-HCV and HBsAg) in these patients. The automated Bio-Flash technology-based screening algorithm also reduced the operation time by 85.0% (205 min) per day, saving up to 24 h/week. In conclusion, the use of the newly proposed screening algorithm based on the automated Bio-Flash technology can provide an advantage over the use of conventional algorithms based on manual methods for screening for HIV, HBV, HCV, and syphilis before GI endoscopy. PMID:27707942
Jun, Zhou; Zhen, Chen; QuiuLi, Zhang; YuanQi, An; Casado, Verónica Vocero; Fan, Yuan
2016-12-01
Currently, conventional enzyme immunoassays which use manual gold immunoassays and colloidal tests (GICTs) are used as screening tools to detect Treponema pallidum (syphilis), hepatitis B virus (HBV), hepatitis C virus (HCV), human immunodeficiency virus type 1 (HIV-1), and HIV-2 in patients undergoing surgery. The present observational, cross-sectional study compared the sensitivity, specificity, and work flow characteristics of the conventional algorithm with manual GICTs with those of a newly proposed algorithm that uses the automated Bio-Flash technology as a screening tool in patients undergoing gastrointestinal (GI) endoscopy. A total of 956 patients were examined for the presence of serological markers of infection with HIV-1/2, HCV, HBV, and T. pallidum The proposed algorithm with the Bio-Flash technology was superior for the detection of all markers (100.0% sensitivity and specificity for detection of anti-HIV and anti-HCV antibodies, HBV surface antigen [HBsAg], and T. pallidum) compared with the conventional algorithm based on the manual method (80.0% sensitivity and 98.6% specificity for the detection of anti-HIV, 75.0% sensitivity for the detection of anti-HCV, 94.7% sensitivity for the detection of HBsAg, and 100% specificity for the detection of anti-HCV and HBsAg) in these patients. The automated Bio-Flash technology-based screening algorithm also reduced the operation time by 85.0% (205 min) per day, saving up to 24 h/week. In conclusion, the use of the newly proposed screening algorithm based on the automated Bio-Flash technology can provide an advantage over the use of conventional algorithms based on manual methods for screening for HIV, HBV, HCV, and syphilis before GI endoscopy. Copyright © 2016 Jun et al.
Inter-arch digital model vs. manual cast measurements: Accuracy and reliability.
Kiviahde, Heikki; Bukovac, Lea; Jussila, Päivi; Pesonen, Paula; Sipilä, Kirsi; Raustia, Aune; Pirttiniemi, Pertti
2017-06-28
The purpose of this study was to evaluate the accuracy and reliability of inter-arch measurements using digital dental models and conventional dental casts. Thirty sets of dental casts with permanent dentition were examined. Manual measurements were done with a digital caliper directly on the dental casts, and digital measurements were made on 3D models by two independent examiners. Intra-class correlation coefficients (ICC), a paired sample t-test or Wilcoxon signed-rank test, and Bland-Altman plots were used to evaluate intra- and inter-examiner error and to determine the accuracy and reliability of the measurements. The ICC values were generally good for manual and excellent for digital measurements. The Bland-Altman plots of all the measurements showed good agreement between the manual and digital methods and excellent inter-examiner agreement using the digital method. Inter-arch occlusal measurements on digital models are accurate and reliable and are superior to manual measurements.
Interactive 3D segmentation using connected orthogonal contours.
de Bruin, P W; Dercksen, V J; Post, F H; Vossepoel, A M; Streekstra, G J; Vos, F M
2005-05-01
This paper describes a new method for interactive segmentation that is based on cross-sectional design and 3D modelling. The method represents a 3D model by a set of connected contours that are planar and orthogonal. Planar contours overlayed on image data are easily manipulated and linked contours reduce the amount of user interaction.1 This method solves the contour-to-contour correspondence problem and can capture extrema of objects in a more flexible way than manual segmentation of a stack of 2D images. The resulting 3D model is guaranteed to be free of geometric and topological errors. We show that manual segmentation using connected orthogonal contours has great advantages over conventional manual segmentation. Furthermore, the method provides effective feedback and control for creating an initial model for, and control and steering of, (semi-)automatic segmentation methods.
ASPECTS: an automation-assisted SPE method development system.
Li, Ming; Chou, Judy; King, Kristopher W; Yang, Liyu
2013-07-01
A typical conventional SPE method development (MD) process usually involves deciding the chemistry of the sorbent and eluent based on information about the analyte; experimentally preparing and trying out various combinations of adsorption chemistry and elution conditions; quantitatively evaluating the various conditions; and comparing quantitative results from all combination of conditions to select the best condition for method qualification. The second and fourth steps have mostly been performed manually until now. We developed an automation-assisted system that expedites the conventional SPE MD process by automating 99% of the second step, and expedites the fourth step by automatically processing the results data and presenting it to the analyst in a user-friendly format. The automation-assisted SPE MD system greatly saves the manual labor in SPE MD work, prevents analyst errors from causing misinterpretation of quantitative results, and shortens data analysis and interpretation time.
Kume, Teruyoshi; Kim, Byeong-Keuk; Waseda, Katsuhisa; Sathyanarayana, Shashidhar; Li, Wenguang; Teo, Tat-Jin; Yock, Paul G; Fitzgerald, Peter J; Honda, Yasuhiro
2013-02-01
The aim of this study was to evaluate a new fully automated lumen border tracing system based on a novel multifrequency processing algorithm. We developed the multifrequency processing method to enhance arterial lumen detection by exploiting the differential scattering characteristics of blood and arterial tissue. The implementation of the method can be integrated into current intravascular ultrasound (IVUS) hardware. This study was performed in vivo with conventional 40-MHz IVUS catheters (Atlantis SR Pro™, Boston Scientific Corp, Natick, MA) in 43 clinical patients with coronary artery disease. A total of 522 frames were randomly selected, and lumen areas were measured after automatically tracing lumen borders with the new tracing system and a commercially available tracing system (TraceAssist™) referred to as the "conventional tracing system." The data assessed by the two automated systems were compared with the results of manual tracings by experienced IVUS analysts. New automated lumen measurements showed better agreement with manual lumen area tracings compared with those of the conventional tracing system (correlation coefficient: 0.819 vs. 0.509). When compared against manual tracings, the new algorithm also demonstrated improved systematic error (mean difference: 0.13 vs. -1.02 mm(2) ) and random variability (standard deviation of difference: 2.21 vs. 4.02 mm(2) ) compared with the conventional tracing system. This preliminary study showed that the novel fully automated tracing system based on the multifrequency processing algorithm can provide more accurate lumen border detection than current automated tracing systems and thus, offer a more reliable quantitative evaluation of lumen geometry. Copyright © 2011 Wiley Periodicals, Inc.
Daniel, Kaemmerer; Maria, Athelogou; Amelie, Lupp; Isabell, Lenhardt; Stefan, Schulz; Luisa, Peter; Merten, Hommann; Vikas, Prasad; Gerd, Binnig; Paul, Baum Richard
2014-01-01
Background: Manual evaluation of somatostatin receptor (SSTR) immunohistochemistry (IHC) is a time-consuming and cost-intensive procedure. Aim of the study was to compare manual evaluation of SSTR subtype IHC to an automated software-based analysis, and to in-vivo imaging by SSTR-based PET/CT. Methods: We examined 25 gastroenteropancreatic neuroendocrine tumor (GEP-NET) patients and correlated their in-vivo SSTR-PET/CT data (determined by the standardized uptake values SUVmax,-mean) with the corresponding ex-vivo IHC data of SSTR subtype (1, 2A, 4, 5) expression. Exactly the same lesions were imaged by PET/CT, resected and analyzed by IHC in each patient. After manual evaluation, the IHC slides were digitized and automatically evaluated for SSTR expression by Definiens XD software. A virtual IHC score “BB1” was created for comparing the manual and automated analysis of SSTR expression. Results: BB1 showed a significant correlation with the corresponding conventionally determined Her2/neu score of the SSTR-subtypes 2A (rs: 0.57), 4 (rs: 0.44) and 5 (rs: 0.43). BB1 of SSTR2A also significantly correlated with the SUVmax (rs: 0.41) and the SUVmean (rs: 0.50). Likewise, a significant correlation was seen between the conventionally evaluated SSTR2A status and the SUVmax (rs: 0.42) and SUVmean (rs: 0.62).Conclusion: Our data demonstrate that the evaluation of the SSTR status by automated analysis (BB1 score), using digitized histopathology slides (“virtual microscopy”), corresponds well with the SSTR2A, 4 and 5 expression as determined by conventional manual histopathology. The BB1 score also exhibited a significant association to the SSTR-PET/CT data in accordance with the high affinity profile of the SSTR analogues used for imaging. PMID:25197368
Shukla, Surabhi; Einstein, A; Shukla, Abhilasha; Mishra, Deepika
2015-01-01
Background: Liquid-based cytology (LBC), recommended in the mass screening of potentially malignant cervical and oral lesions, suffers from high cost owing to the use of expensive automated devices and materials. Considering the need for cost-effective LBC techniques, we evaluated the efficacy of an inexpensive manual LBC (MLBC) technique against conventional cytological technique in terms of specimen adequacy and smear quality of oral smears. Materials and Methods: Cytological samples were collected from 21 patients using a cytobrush device. After preparation of a conventional smear, the brush containing the remaining sample was immersed in the preservative vial. The preserved material was processed by an MLBC technique and subsequently, direct smears were made from the prepared cell button. Both conventional and MLBC smears were stained by routine Papanicolaou technique and evaluated by an independent observer for the thickness of the smear, cellular distribution, resolution/clarity of cells, cellular staining characteristics and the presence of unsatisfactory background/artifacts. Each parameter was graded as satisfactory; or satisfactory, but limited; or unsatisfactory. Chi-square test was used to compare the values obtained (significance set at P ≤ 0.05). Results: MLBC technique produced a significant number of satisfactory smears with regard to cell distribution, clarity/resolution, staining characteristics and background/artifacts compared to conventional methods. Conclusions: MLBC is a cost-effective cytological technique that may produce oral smears with excellent cytomorphology and longer storage life. PMID:26980958
Correlation and agreement of a digital and conventional method to measure arch parameters.
Nawi, Nes; Mohamed, Alizae Marny; Marizan Nor, Murshida; Ashar, Nor Atika
2018-01-01
The aim of the present study was to determine the overall reliability and validity of arch parameters measured digitally compared to conventional measurement. A sample of 111 plaster study models of Down syndrome (DS) patients were digitized using a blue light three-dimensional (3D) scanner. Digital and manual measurements of defined parameters were performed using Geomagic analysis software (Geomagic Studio 2014 software, 3D Systems, Rock Hill, SC, USA) on digital models and with a digital calliper (Tuten, Germany) on plaster study models. Both measurements were repeated twice to validate the intraexaminer reliability based on intraclass correlation coefficients (ICCs) using the independent t test and Pearson's correlation, respectively. The Bland-Altman method of analysis was used to evaluate the agreement of the measurement between the digital and plaster models. No statistically significant differences (p > 0.05) were found between the manual and digital methods when measuring the arch width, arch length, and space analysis. In addition, all parameters showed a significant correlation coefficient (r ≥ 0.972; p < 0.01) between all digital and manual measurements. Furthermore, a positive agreement between digital and manual measurements of the arch width (90-96%), arch length and space analysis (95-99%) were also distinguished using the Bland-Altman method. These results demonstrate that 3D blue light scanning and measurement software are able to precisely produce 3D digital model and measure arch width, arch length, and space analysis. The 3D digital model is valid to be used in various clinical applications.
Cheng, Yuk Wah; Wilkinson, Jenny M
2015-08-01
This paper reports on an evaluation of the introduction of a blood bank automation system (Ortho AutoVue(®) Innova) in a hospital blood bank by considering the performance and workflow as compared with manual methods. The turnaround time was found to be 45% faster than the manual method. The concordance rate was found to be 100% for both ABO/Rh(D) typing and antibody screening in both of the systems and there was no significant difference in detection sensitivity for clinically significant antibodies. The Ortho AutoVue(®) Innova automated blood banking system streamlined the routine pre-transfusion testing in hospital blood bank with high throughput, equivalent sensitivity and reliability as compared with conventional manual method. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ichikawa, Tamaki; Kitanosono, Takashi; Koizumi, Jun; Ogushi, Yoichi; Tanaka, Osamu; Endo, Jun; Hashimoto, Takeshi; Kawada, Shuichi; Saito, Midori; Kobayashi, Makiko; Imai, Yutaka
2007-12-20
We evaluated the usefulness of radiological reporting that combines continuous speech recognition (CSR) and error correction by transcriptionists. Four transcriptionists (two with more than 10 years' and two with less than 3 months' transcription experience) listened to the same 100 dictation files and created radiological reports using conventional transcription and a method that combined CSR with manual error correction by the transcriptionists. We compared the 2 groups using the 2 methods for accuracy and report creation time and evaluated the transcriptionists' inter-personal dependence on accuracy rate and report creation time. We used a CSR system that did not require the training of the system to recognize the user's voice. We observed no significant difference in accuracy between the 2 groups and 2 methods that we tested, though transcriptionists with greater experience transcribed faster than those with less experience using conventional transcription. Using the combined method, error correction speed was not significantly different between two groups of transcriptionists with different levels of experience. Combining CSR and manual error correction by transcriptionists enabled convenient and accurate radiological reporting.
Foda, Abd Al-Rahman Mohammad
2013-05-01
Manual tissue microarray (TMA) construction had been introduced to avoid the high cost of automated and semiautomated techniques. The cheapest and simplest technique for constructing manual TMA was that of using mechanical pencil tips. This study was carried out to modify this method, aiming to raise its quality to reach that of expensive ones. Some modifications were introduced to Shebl's technique. Two conventional mechanical pencil tips of different diameters were used to construct the recipient blocks. A source of mild heat was used, and blocks were incubated at 38°C overnight. With our modifications, 3 high-density TMA blocks were constructed. We successfully performed immunostaining without substantial tissue loss. Our modifications increased the number of cores per block and improved the stability of the cores within the paraffin block. This new, modified technique is a good alternative for expensive machines in many laboratories.
Reliable enumeration of malaria parasites in thick blood films using digital image analysis.
Frean, John A
2009-09-23
Quantitation of malaria parasite density is an important component of laboratory diagnosis of malaria. Microscopy of Giemsa-stained thick blood films is the conventional method for parasite enumeration. Accurate and reproducible parasite counts are difficult to achieve, because of inherent technical limitations and human inconsistency. Inaccurate parasite density estimation may have adverse clinical and therapeutic implications for patients, and for endpoints of clinical trials of anti-malarial vaccines or drugs. Digital image analysis provides an opportunity to improve performance of parasite density quantitation. Accurate manual parasite counts were done on 497 images of a range of thick blood films with varying densities of malaria parasites, to establish a uniformly reliable standard against which to assess the digital technique. By utilizing descriptive statistical parameters of parasite size frequency distributions, particle counting algorithms of the digital image analysis programme were semi-automatically adapted to variations in parasite size, shape and staining characteristics, to produce optimum signal/noise ratios. A reliable counting process was developed that requires no operator decisions that might bias the outcome. Digital counts were highly correlated with manual counts for medium to high parasite densities, and slightly less well correlated with conventional counts. At low densities (fewer than 6 parasites per analysed image) signal/noise ratios were compromised and correlation between digital and manual counts was poor. Conventional counts were consistently lower than both digital and manual counts. Using open-access software and avoiding custom programming or any special operator intervention, accurate digital counts were obtained, particularly at high parasite densities that are difficult to count conventionally. The technique is potentially useful for laboratories that routinely perform malaria parasite enumeration. The requirements of a digital microscope camera, personal computer and good quality staining of slides are potentially reasonably easy to meet.
Alp, Alpaslan; Us, Dürdal; Hasçelik, Gülşen
2004-01-01
Rapid quantitative molecular methods are very important for the diagnosis of human immunodeficiency virus (HIV) infections, assessment of prognosis and follow up. The purpose of this study was to compare and evaluate the performances of conventional manual extraction method and automated MagNA Pure system, for the nucleic acid isolation step which is the first and most important step in molecular diagnosis of HIV infections. Plasma samples of 35 patients in which anti-HIV antibodies were found as positive by microparticule enzyme immunoassay and confirmed by immunoblotting method, were included in the study. The nucleic acids obtained simultaneously by manual isolation kit (Cobas Amplicor, HIV-1 Monitor Test, version 1.5, Roche Diagnostics) and automated system (MagNA Pure LC Total Nucleic Acid Isolation Kit, Roche Diagnostics), were amplified and detected in Cobas Amplicor (Roche Diagnostics) instrument. Twenty three of 35 samples (65.7%) were found to be positive, and 9 (25.7%) were negative by both of the methods. The agreement between the methods were detected as 91.4%, for qualitative results. Viral RNA copies detected by manual and MagNA Pure isolation methods were found between 76.0-7.590.000 (mean: 487.143) and 113.0-20.300.0000 (mean: 2.174.097) copies/ml, respectively. When both of the overall and individual results were evaluated, the number of RNA copies obtained with automatized system, were found higher than the manual method (p<0.05). Three samples which had low numbers of nucleic acids (113, 773, 857, respectively) with MagNA Pure, yielded negative results with manual method. In conclusion, the automatized MagNA Pure system was found to be a reliable, rapid and practical method for the isolation of HIV-RNA.
The integrated manual and automatic control of complex flight systems
NASA Technical Reports Server (NTRS)
Schmidt, D. K.
1983-01-01
Development of a unified control synthesis methodology for complex and/or non-conventional flight vehicles, and prediction techniques for the handling characteristics of such vehicles are reported. Identification of pilot dynamics and objectives, using time domain and frequency domain methods is proposed.
DOT National Transportation Integrated Search
2011-01-01
Integral abutment (IA) construction has become the preferred method over conventional construction for use with typical highway bridges. However, the use of these structures is limited due to state mandated length and skew limitations. To expand thei...
Kogot, Joshua M.; Zhang, Yanting; Moore, Stephen J.; Pagano, Paul; Stratis-Cullum, Dimitra N.; Chang-Yen, David; Turewicz, Marek; Pellegrino, Paul M.; de Fusco, Andre; Soh, H. Tom; Stagliano, Nancy E.
2011-01-01
Bacterial surface peptide display has gained popularity as a method of affinity reagent generation for a wide variety of applications ranging from drug discovery to pathogen detection. In order to isolate the bacterial clones that express peptides with high affinities to the target molecule, multiple rounds of manual magnetic activated cell sorting (MACS) followed by multiple rounds of fluorescence activated cell sorting (FACS) are conventionally used. Although such manual methods are effective, alternative means of library screening which improve the reproducibility, reduce the cost, reduce cross contamination, and minimize exposure to hazardous target materials are highly desired for practical application. Toward this end, we report the first semi-automated system demonstrating the potential for screening bacterially displayed peptides using disposable microfluidic cartridges. The Micro-Magnetic Separation platform (MMS) is capable of screening a bacterial library containing 3×1010 members in 15 minutes and requires minimal operator training. Using this system, we report the isolation of twenty-four distinct peptide ligands that bind to the protective antigen (PA) of Bacilus anthracis in three rounds of selection. A consensus motif WXCFTC was found using the MMS and was also found in one of the PA binders isolated by the conventional MACS/FACS approach. We compared MMS and MACS rare cell recovery over cell populations ranging from 0.1% to 0.0000001% and found that both magnetic sorting methods could recover cells down to 0.0000001% initial cell population, with the MMS having overall lower standard deviation of cell recovery. We believe the MMS system offers a compelling approach towards highly efficient, semi-automated screening of molecular libraries that is at least equal to manual magnetic sorting methods and produced, for the first time, 15-mer peptide binders to PA protein that exhibit better affinity and specificity than peptides isolated using conventional MACS/FACS. PMID:22140433
Alford, Timothy J.; Roberts, W. Eugene; Hartsfield, James K.; Eckert, George J.; Snyder, Ronald J.
2016-01-01
Objective Utilize American Board of Orthodontics (ABO) cast/radiographic evaluation (CRE) to compare a series of 63 consecutive patients, finished with manual wire bending (conventional) treatment, vs a subsequent series of 69 consecutive patients, finished by the same orthodontist using the SureSmile™ (SS) method. Materials and Methods Records of 132 nonextraction patients were scored by a calibrated examiner blinded to treatment mode. Age and discrepancy index (DI) between groups were compared by t-tests. A chi-square test was used to compare for differences in sex and whether the patient was treated using braces only (no orthopedic correction). Analysis of covariance tested for differences in CRE outcomes and treatment times, with sex and DI included as covariates. A logarithmic transformation of CRE outcomes and treatment times was used because their distributions were skewed. Significance was defined as P < .05. Results Compared with conventional finishing, SS patients had significantly lower DI scores, less treatment time (~7 months), and better CRE scores for first-order alignment-rotation and interproximal space closure; however, second-order root angulation (RA) was inferior. Conclusion SS patients were treated in less time to better CRE scores for first-order rotation (AR) and interproximal space closure (IC) but on the average, malocclusions were less complex and second order root alignment was inferior, compared with patients finished with manual wire bending. PMID:21261488
Comparison of Pictorial Techniques for Guiding Performance During Training.
ERIC Educational Resources Information Center
Miller, Elmo E.
An experimental program was conducted to develop effective methods for producing and utilizing filmed demonstrations and instructional manuals. Four variations on conventional filmed demonstrations were evaluated: 1) revising an Army film through repeated tryouts with novices, 2) stopping the projector after each step is demonstrated to allow…
Birth, Matthias; Markert, Uwe; Strik, Martin; Wohlschläger, Charlotte; Brugmans, Frederik; Gerberding, Jürgen; Bruch, Hans P
2002-01-15
In orthotopic liver transplantation the incidence of biliary complications is up to 49%. In view of the relative frequency of such complications despite seemingly good preconditions, method-related disadvantages of conventional suture must also be considered as a possible cause. These include perforating needle injury of the choledochal wall with at least temporary exposure of suture material in the lumen, suboptimal approximation of the mucosa, and an additional decrease in blood flow in the choledochal stumps as a result of suture-related tissue strangulation. Hence the search for alternative anastomosis techniques. To evaluate the surgical suitability of extramucosal titanium clips (Vascular Closure Staples; VCS) in comparison with conventional manual suture, a study was performed in 36 pigs, which were randomly assigned to 4 groups, each containing 9 animals. Choledochal excision was performed in 18 pigs and transection in the other 18 pigs; end-to-end anastomosis was then carried out, using a VCS stapler in half of the animals in each of these two groups and conventional manual suture in the other half. Pre- and postanastomotic blood flow was measured during the surgery with the aid of a laser Doppler flow meter. The long-term behavior of the closure techniques was ascertained by regular laboratory checks over the ensuing 6-month observation period, after which the pigs were killed so that the specimens could be harvested. Using medium-sized VCS clips, we were able to create a tension-free, everted biliary anastomosis with exact mucosal approximation and no narrowing of the lumen, and without any technical problems during the performance of the procedure. Measurements with the laser Doppler flow meter showed well-preserved anastomotic blood flow after clip reconstruction, with significantly higher perfusion values than after manual suture. The postoperative courses of the investigated laboratory parameters did not reveal any significant differences between the two methods. In contrast, histomorphometric evaluation showed wall thickness and thus fibrosis in the anastomosis region to be less in the clip group than in the suture group (median: 510 microm versus 660 microm, P<0.001). In the pigs in which clip anastomosis was used, there were no detectable anastomotic stenoses; in the pigs in which conventional suture was used, however, ultrasonography revealed five anastomoses with varying degrees of narrowing. Extramucosal VCS clip anastomosis not only offers potential advantages with respect to nonpenetrating and optimal mucosal contact, investigations in animals also show it to be superior to conventional manual suture as regards anastomotic blood flow and medium-term fibrosis formation. We believe that our data and the available literature warrant a clinical evaluation of this technique in appropriate studies.
NASA Astrophysics Data System (ADS)
Lynch, John A.; Zaim, Souhil; Zhao, Jenny; Stork, Alexander; Peterfy, Charles G.; Genant, Harry K.
2000-06-01
A technique for segmentation of articular cartilage from 3D MRI scans of the knee has been developed. It overcomes the limitations of the conventionally used region growing techniques, which are prone to inter- and intra-observer variability, and which can require much manual intervention. We describe a hybrid segmentation method combining expert knowledge with directionally oriented Canny filters, cost functions and cubic splines. After manual initialization, the technique utilized 3 cost functions which aided automated detection of cartilage and its boundaries. Using the sign of the edge strength, and the local direction of the boundary, this technique is more reliable than conventional 'snakes,' and the user had little control over smoothness of boundaries. This means that the automatically detected boundary can conform to the true shape of the real boundary, also allowing reliable detection of subtle local lesions on the normally smooth cartilage surface. Manual corrections, with possible re-optimization were sometimes needed. When compared to the conventionally used region growing techniques, this newly described technique measured local cartilage volume with 3 times better reproducibility, and involved two thirds less human interaction. Combined with the use of 3D image registration, the new technique should also permit unbiased segmentation of followup scans by automated initialization from a baseline segmentation of an earlier scan of the same patient.
Calibrating reaction rates for the CREST model
NASA Astrophysics Data System (ADS)
Handley, Caroline A.; Christie, Michael A.
2017-01-01
The CREST reactive-burn model uses entropy-dependent reaction rates that, until now, have been manually tuned to fit shock-initiation and detonation data in hydrocode simulations. This paper describes the initial development of an automatic method for calibrating CREST reaction-rate coefficients, using particle swarm optimisation. The automatic method is applied to EDC32, to help develop the first CREST model for this conventional high explosive.
Reproducible segmentation of white matter hyperintensities using a new statistical definition.
Damangir, Soheil; Westman, Eric; Simmons, Andrew; Vrenken, Hugo; Wahlund, Lars-Olof; Spulber, Gabriela
2017-06-01
We present a method based on a proposed statistical definition of white matter hyperintensities (WMH), which can work with any combination of conventional magnetic resonance (MR) sequences without depending on manually delineated samples. T1-weighted, T2-weighted, FLAIR, and PD sequences acquired at 1.5 Tesla from 119 subjects from the Kings Health Partners-Dementia Case Register (healthy controls, mild cognitive impairment, Alzheimer's disease) were used. The segmentation was performed using a proposed definition for WMH based on the one-tailed Kolmogorov-Smirnov test. The presented method was verified, given all possible combinations of input sequences, against manual segmentations and a high similarity (Dice 0.85-0.91) was observed. Comparing segmentations with different input sequences to one another also yielded a high similarity (Dice 0.83-0.94) that exceeded intra-rater similarity (Dice 0.75-0.91). We compared the results with those of other available methods and showed that the segmentation based on the proposed definition has better accuracy and reproducibility in the test dataset used. Overall, the presented definition is shown to produce accurate results with higher reproducibility than manual delineation. This approach can be an alternative to other manual or automatic methods not only because of its accuracy, but also due to its good reproducibility.
Manual and automatic flight control during severe turbulence penetration
NASA Technical Reports Server (NTRS)
Johnston, D. E.; Klein, R. H.; Hoh, R. H.
1976-01-01
An analytical and experimental investigation of possible contributing factors in jet aircraft turbulence upsets was conducted. Major contributing factors identified included autopilot and display deficiencies, the large aircraft inertia and associated long response time, and excessive pilot workload. An integrated flight and thrust energy management director system was synthesized. The system was incorporated in a moving-base simulation and evaluated using highly experienced airline pilots. The evaluation included comparison of pilot workload and flight performance during severe turbulence penetration utilizing four control/display concepts: manual control with conventional full panel display, conventional autopilot (A/P-A) with conventional full panel display, improved autopilot (A/P-B) with conventional full panel display plus thrust director display, and longitudinal flight director with conventional full panel display plus thrust director display. Simulation results show improved performance, reduced pilot workload, and a pilot preference for the autopilot system controlling to the flight director command and manual control of thrust following the trim thrust director.
Leaf epidermis images for robust identification of plants
da Silva, Núbia Rosa; Oliveira, Marcos William da Silva; Filho, Humberto Antunes de Almeida; Pinheiro, Luiz Felipe Souza; Rossatto, Davi Rodrigo; Kolb, Rosana Marta; Bruno, Odemir Martinez
2016-01-01
This paper proposes a methodology for plant analysis and identification based on extracting texture features from microscopic images of leaf epidermis. All the experiments were carried out using 32 plant species with 309 epidermal samples captured by an optical microscope coupled to a digital camera. The results of the computational methods using texture features were compared to the conventional approach, where quantitative measurements of stomatal traits (density, length and width) were manually obtained. Epidermis image classification using texture has achieved a success rate of over 96%, while success rate was around 60% for quantitative measurements taken manually. Furthermore, we verified the robustness of our method accounting for natural phenotypic plasticity of stomata, analysing samples from the same species grown in different environments. Texture methods were robust even when considering phenotypic plasticity of stomatal traits with a decrease of 20% in the success rate, as quantitative measurements proved to be fully sensitive with a decrease of 77%. Results from the comparison between the computational approach and the conventional quantitative measurements lead us to discover how computational systems are advantageous and promising in terms of solving problems related to Botany, such as species identification. PMID:27217018
Novel non-contact control system of electric bed for medical healthcare.
Lo, Chi-Chun; Tsai, Shang-Ho; Lin, Bor-Shyh
2017-03-01
A novel non-contact controller of the electric bed for medical healthcare was proposed in this study. Nowadays, the electric beds are widely used for hospitals and home-care, and the conventional control method of the electric beds usually involves in the manual operation. However, it is more difficult for the disabled and bedridden patients, who might totally depend on others, to operate the conventional electric beds by themselves. Different from the current controlling method, the proposed system provides a new concept of controlling the electric bed via visual stimuli, without manual operation. The disabled patients could operate the electric bed by focusing on the control icons of a visual stimulus tablet in the proposed system. Besides, a wearable and wireless EEG acquisition module was also implemented to monitor the EEG signals of patients. The experimental results showed that the proposed system successfully measured and extracted the EEG features related to visual stimuli, and the disabled patients could operate the adjustable function of the electric bed by themselves to effectively reduce the long-term care burden.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winkler, Jon; Booten, Chuck
Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity.more » The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.« less
Baltas, Dimos; Karabis, Andreas; Stock, Markus; Dimopoulos, Johannes; Georg, Dietmar; Pötter, Richard; Kirisits, Christian
2011-01-01
Purpose The purpose of this study was to compare two inverse planning algorithms for cervical cancer brachytherapy and a conventional manual treatment planning according to the MUW (Medical University of Vienna) protocol. Material and methods For 20 patients, manually optimized, and, inversely optimized treatment plans with Hybrid Inverse treatment Planning and Optimization (HIPO) and with Inverse Planning Simulated Annealing (IPSA) were created. Dosimetric parameters, absolute volumes of normal tissue receiving reference doses, absolute loading times of tandem, ring and interstitial needles, Paddick and COIN conformity indices were evaluated. Results HIPO was able to achieve a similar dose distribution to manual planning with the restriction of high dose regions. It reduced the loading time of needles and the overall treatment time. The values of both conformity indices were the lowest. IPSA was able to achieve acceptable dosimetric results. However, it overloaded the needles. This resulted in high dose regions located in the normal tissue. The Paddick index for the volume of two times prescribed dose was outstandingly low. Conclusions HIPO can produce clinically acceptable treatment plans with the elimination of high dose regions in normal tissue. Compared to IPSA, it is an inverse optimization method which takes into account current clinical experience gained from manual treatment planning. PMID:27853479
A quick and effective method of limb preparation with health, safety and efficiency benefits.
Naderi, N; Maw, K; Thomas, M; Boyce, D E; Shokrollahi, K
2012-03-01
Pre-operative limb preparation (PLP) usually involves lifting the limb and holding it in a fixed 'static' posture for several minutes. This is hazardous to theatre staff. Furthermore, 'painting' the limb can be time consuming and difficult areas such as between toes and fingers may remain unsterile. We demonstrate the time efficiency and asepsis achieved using the 'sterile bag' preparation technique. An additional advantage is the ability to prepare and anaesthetise a limb prior to theatre, increasing efficiency substantially for units with a large throughput of cases, such as day-case hand surgery lists. We monitored the duration of PLP in 20 patients using the 'sterile bag' technique compared to 20 patients using a conventional 'painting' method. Additionally, microbiology samples acquired from prepared upper limbs of 27 sequential patients operated on by a single surgeon over a two-month period were sent for culture immediately prior to commencement of surgery. The mean duration of the 'sterile bag' PLP was significantly lower than that of the conventional method (24 seconds vs 85 seconds, p=0.045). The technique can take as little as ten seconds (n=1). Final microbiology reports showed no growth for any of the 27 patients from whom a culture sample was taken. The sterile bag technique is effective in achieving asepsis, has the potential to increase theatre efficiency and reduces manual handling hazards compared to the conventional method. It is now taught to all theatre staff in our hospital during manual handling training. It can be undertaken in approximately ten seconds with practice for the upper limb.
Péterffy, A; Calabrese, E
1979-01-01
A U.S.-made TA-30 model stapling device was utilized to close the bronchial stump in 146 patients, while conventional manual suturing with chromic catgut was performed for the same purpose in 152 patients. The two groups were comparable in respect of pre-operative status and operative diagnosis. Patients, in whom the stapler was utilized, showed a decreased incidence of bronchial fistula (1% vs. 3%) and empyema without fistula (1% vs. 3%). The stapler, compared with conventional manual sutures, allows a simpler and swifter suture of the bronchial stump, reduces the contamination of the operative field, achieves uniform and tighter closure of the bronchus, leaves a better preserved terminal blood perfusion of the stump and utilizes a more tolerated sewing material with less resultant tissue inflammation.
Neubert, Ales; Fripp, Jurgen; Engstrom, Craig; Gal, Yaniv; Crozier, Stuart; Kingsley, Michael I C
2014-11-01
Magnetic resonance (MR) examinations of morphologic characteristics of intervertebral discs (IVDs) have been used extensively for biomechanical studies and clinical investigations of the lumbar spine. Traditionally, the morphologic measurements have been performed using time- and expertise-intensive manual segmentation techniques not well suited for analyses of large-scale studies.. The purpose of this study is to introduce and validate a semiautomated method for measuring IVD height and mean sagittal area (and volume) from MR images to determine if it can replace the manual assessment and enable analyses of large MR cohorts. This study compares semiautomated and manual measurements and assesses their reliability and agreement using data from repeated MR examinations. Seven healthy asymptomatic males underwent 1.5-T MR examinations of the lumbar spine involving sagittal T2-weighted fast spin-echo images obtained at baseline, pre-exercise, and postexercise conditions. Measures of the mean height and the mean sagittal area of lumbar IVDs (L1-L2 to L4-L5) were compared for two segmentation approaches: a conventional manual method (10-15 minutes to process one IVD) and a specifically developed semiautomated method (requiring only a few mouse clicks to process each subject). Both methods showed strong test-retest reproducibility evaluated on baseline and pre-exercise examinations with strong intraclass correlations for the semiautomated and manual methods for mean IVD height (intraclass correlation coefficient [ICC]=0.99, 0.98) and mean IVD area (ICC=0.98, 0.99), respectively. A bias (average deviation) of 0.38 mm (4.1%, 95% confidence interval 0.18-0.59 mm) was observed between the manual and semiautomated methods for the IVD height, whereas there was no statistically significant difference for the mean IVD area (0.1%±3.5%). The semiautomated and manual methods both detected significant exercise-induced changes in IVD height (0.20 and 0.28 mm) and mean IVD area (5.7 and 8.3 mm(2)), respectively. The presented semiautomated method provides an alternative to time- and expertise-intensive manual procedures for analysis of larger, cross-sectional, interventional, and longitudinal MR studies for morphometric analyses of lumbar IVDs. Copyright © 2014 Elsevier Inc. All rights reserved.
Rayarao, Geetha; Biederman, Robert W W; Williams, Ronald B; Yamrozik, June A; Lombardi, Richard; Doyle, Mark
2018-01-01
To establish the clinical validity and accuracy of automatic thresholding and manual trimming (ATMT) by comparing the method with the conventional contouring method for in vivo cardiac volume measurements. CMR was performed on 40 subjects (30 patients and 10 controls) using steady-state free precession cine sequences with slices oriented in the short-axis and acquired contiguously from base to apex. Left ventricular (LV) volumes, end-diastolic volume, end-systolic volume, and stroke volume (SV) were obtained with ATMT and with the conventional contouring method. Additionally, SV was measured independently using CMR phase velocity mapping (PVM) of the aorta for validation. Three methods of calculating SV were compared by applying Bland-Altman analysis. The Bland-Altman standard deviation of variation (SD) and offset bias for LV SV for the three sets of data were: ATMT-PVM (7.65, [Formula: see text]), ATMT-contours (7.85, [Formula: see text]), and contour-PVM (11.01, 4.97), respectively. Equating the observed range to the error contribution of each approach, the error magnitude of ATMT:PVM:contours was in the ratio 1:2.4:2.5. Use of ATMT for measuring ventricular volumes accommodates trabeculae and papillary structures more intuitively than contemporary contouring methods. This results in lower variation when analyzing cardiac structure and function and consequently improved accuracy in assessing chamber volumes.
Alford, Timothy J; Roberts, W Eugene; Hartsfield, James K; Eckert, George J; Snyder, Ronald J
2011-05-01
Utilize American Board of Orthodontics (ABO) cast/radiographic evaluation (CRE) to compare a series of 63 consecutive patients, finished with manual wire bending (conventional) treatment, vs a subsequent series of 69 consecutive patients, finished by the same orthodontist using the SureSmile™ (SS) method. Records of 132 nonextraction patients were scored by a calibrated examiner blinded to treatment mode. Age and discrepancy index (DI) between groups were compared by t-tests. A chi-square test was used to compare for differences in sex and whether the patient was treated using braces only (no orthopedic correction). Analysis of covariance tested for differences in CRE outcomes and treatment times, with sex and DI included as covariates. A logarithmic transformation of CRE outcomes and treatment times was used because their distributions were skewed. Significance was defined as P < .05. Compared with conventional finishing, SS patients had significantly lower DI scores, less treatment time (∼7 months), and better CRE scores for first-order alignment-rotation and interproximal space closure; however, second-order root angulation (RA) was inferior. SS patients were treated in less time to better CRE scores for first-order rotation (AR) and interproximal space closure (IC) but on the average, malocclusions were less complex and second order root alignment was inferior, compared with patients finished with manual wire bending.
Arnal, Jean-Michel; Garnero, Aude; Novotni, Dominik; Corno, Gaëlle; Donati, Stéphane-Yannis; Demory, Didier; Quintana, Gabrielle; Ducros, Laurent; Laubscher, Thomas; Durand-Gasselin, Jacques
2018-01-01
There is an equipoise regarding closed-loop ventilation modes and the ability to reduce workload for providers. On one hand some settings are managed by the ventilator but on another hand the automatic mode introduces new settings for the user. This randomized controlled trial compared the number of manual ventilator setting changes between a full closed loop ventilation and oxygenation mode (INTELLiVENT-ASV®) and conventional ventilation modes (volume assist control and pressure support) in Intensive Care Unit (ICU) patients. The secondary endpoints were to compare the number of arterial blood gas analysis, the sedation dose and the user acceptance. Sixty subjects with an expected duration of mechanical ventilation of at least 48 hours were randomized to be ventilated using INTELLiVENT-ASV® or conventional modes with a protocolized weaning. All manual ventilator setting changes were recorded continuously from inclusion to successful extubation or death. Arterial blood gases were performed upon decision of the clinician in charge. User acceptance score was assessed for nurses and physicians once daily using a Likert Scale. The number of manual ventilator setting changes per 24 h-period per subject was lower in INTELLiVENT-ASV® as compared to conventional ventilation group (5 [4-7] versus 10 [7-17]) manuals settings per subject per day [P<0.001]). The number of arterial blood gas analysis and the sedation doses were not significantly different between the groups. Nurses and physicians reported that INTELLiVENT-ASV® was significantly easier to use as compared to conventional ventilation (P<0.001 for nurses and P<0.01 for physicians). For mechanically ventilated ICU patients, INTELLiVENT-ASV® significantly reduces the number of manual ventilator setting changes with the same number of arterial blood gas analysis and sedation dose, and is easier to use for the caregivers as compared to conventional ventilation modes.
A guide to best practices for Gene Ontology (GO) manual annotation
Balakrishnan, Rama; Harris, Midori A.; Huntley, Rachael; Van Auken, Kimberly; Cherry, J. Michael
2013-01-01
The Gene Ontology Consortium (GOC) is a community-based bioinformatics project that classifies gene product function through the use of structured controlled vocabularies. A fundamental application of the Gene Ontology (GO) is in the creation of gene product annotations, evidence-based associations between GO definitions and experimental or sequence-based analysis. Currently, the GOC disseminates 126 million annotations covering >374 000 species including all the kingdoms of life. This number includes two classes of GO annotations: those created manually by experienced biocurators reviewing the literature or by examination of biological data (1.1 million annotations covering 2226 species) and those generated computationally via automated methods. As manual annotations are often used to propagate functional predictions between related proteins within and between genomes, it is critical to provide accurate consistent manual annotations. Toward this goal, we present here the conventions defined by the GOC for the creation of manual annotation. This guide represents the best practices for manual annotation as established by the GOC project over the past 12 years. We hope this guide will encourage research communities to annotate gene products of their interest to enhance the corpus of GO annotations available to all. Database URL: http://www.geneontology.org PMID:23842463
Effect of Robot-Assisted Game Training on Upper Extremity Function in Stroke Patients
2017-01-01
Objective To determine the effects of combining robot-assisted game training with conventional upper extremity rehabilitation training (RCT) on motor and daily functions in comparison with conventional upper extremity rehabilitation training (OCT) in stroke patients. Methods Subjects were eligible if they were able to perform the robot-assisted game training and were divided randomly into a RCT and an OCT group. The RCT group performed one daily session of 30 minutes of robot-assisted game training with a rehabilitation robot, plus one daily session of 30 minutes of conventional rehabilitation training, 5 days a week for 2 weeks. The OCT group performed two daily sessions of 30 minutes of conventional rehabilitation training. The effects of training were measured by a Manual Function Test (MFT), Manual Muscle Test (MMT), Korean version of the Modified Barthel Index (K-MBI) and a questionnaire about satisfaction with training. These measurements were taken before and after the 2-week training. Results Both groups contained 25 subjects. After training, both groups showed significant improvements in motor and daily functions measured by MFT, MMT, and K-MBI compared to the baseline. Both groups demonstrated similar training effects, except motor power of wrist flexion. Patients in the RCT group were more satisfied than those in the OCT group. Conclusion There were no significant differences in changes in most of the motor and daily functions between the two types of training. However, patients in the RCT group were more satisfied than those in the OCT group. Therefore, RCT could be a useful upper extremity rehabilitation training method. PMID:28971037
Plaque reduction over time of an integrated oral hygiene system.
Nunn, Martha E; Ruhlman, C Douglas; Mallatt, Philip R; Rodriguez, Sally M; Ortblad, Katherine M
2004-10-01
This article compares the efficacy of a prototype integrated system (the IntelliClean System from Sonicare and Crest) in the reduction of supragingival plaque to that of a manual toothbrush and conventional toothpaste. The integrated system was compared to a manual toothbrush with conventional toothpaste in a randomized, single-blinded, parallel, 4-week, controlled clinical trial with 100 subjects randomized to each treatment group. There was a low dropout rate, with 89 subjects in the manual toothbrush group (11% loss to follow-up) and 93 subjects in the integrated system group (7% loss to follow-up) completing the study. The Turesky modification of the Quigley and Hein Plaque Index was used to assess full-mouth plaque scores for each subject. Prebrushing plaque scores were obtained at baseline and at 4 weeks after 14 to 20 hours of plaque accumulation. A survey also was conducted at the conclusion of the study to determine the attitude toward the two oral hygiene systems. The integrated system was found to significantly reduce overall and interproximal prebrushing plaque scores over 4 weeks, both by 8.6%, demonstrating statistically significant superiority in overall plaque reduction (P = .002) and interproximal plaque reduction (P < .001) compared to the manual toothbrush with conventional toothpaste, which showed no significant reduction in either overall plaque or interproximal plaque. This study demonstrates that the IntelliClean System from Sonicare and Crest is superior to a manual toothbrush with conventional toothpaste in reducing overall plaque and interproximal plaque over time.
Effectiveness of two synthetic fiber filters for removing white cells from AS-1 red cells.
Pikul, F J; Farrar, R P; Boris, M B; Estok, L; Marlo, D; Wildgen, M; Chaplin, H
1989-09-01
Two commercially available synthetic fiber filters were studied for their effectiveness at removing white cells (WBCs) from AS-1-preserved red cells (RBCs) stored less than or equal to 14 days. In all, 65 filtrations were performed. An automated microprocessor-controlled hydraulic system designed for use with cellulose acetate fiber filters was employed to prepare filtered RBCs before release for transfusion. Studies were also carried out on polyester fiber filters, which are designed to be used in-line during transfusion. Residual WBCs were below the accurate counting range of Coulter counters and of conventional manual chamber counts. An isosmotic ammonium chloride RBC lysis method, plus a modified chamber counting technique, permitted a 270-fold increase over the number of WBCs counted by the conventional manual method. For the polyester fiber-filtered products, residual WBCs per unit were not affected by speed of filtration, prior length of storage, or mechanical tapping during filtration. The effectiveness of WBC removal (mean 99.7%), total residual WBCs (means, 4.8 and 5.5 x 10(6], and RBC recovery (mean, 93%) was the same for both filters. The majority of residual WBCs were lymphocytes. WBC removal and RBC recovery were strikingly superior to results reported with nonfiltration methods.
[Touching cancer: shiatsu as complementary treatment to support cancer patients].
Argash, Oz; Caspi, Opher
2008-01-01
In recent years there has been an increase in the interest of cancer patients in receiving complementary medicine therapies as supportive measures to cure the disease. In response, medical units that combine conventional and complementary medicine (integrative medicine) have been established in leading cancer centers worldwide. In Israel, a special integrative medicine unit that combines mind-body, Chinese medicine, nutrition, herbs, supplements, and manual therapies (such as shiatsu) before, during and after conventional anti-cancer therapies has been established as an integral part of the Davidoff Comprehensive Cancer Center in 2006. Shiatsu represents a group of manual therapeutic techniques, including acupressure. Shiatsu offers cancer patients a non-pharmacologic method to relieve symptoms and improve quality of life throughout the course of illness. Research indicates that acupressure is relatively effective and safe for common cancer-related symptoms such as nausea, vomiting and insomnia. In our experience, shiatsu is also relatively effective and safe for other common symptoms such as fatigue, muscular pain and body image dissatisfaction. Yet, insufficient evidence exists to delineate the best means by which shiatsu and other manual therapies could or should be integrated into routine cancer care. The purpose of the present paper is to describe what is currently known about this topic in order to support decision-making that is based on facts, rather than on myths and misconceptions. We call for more research that examines the effectiveness and safety of shiatsu and other manual therapies in the care of cancer patients.
Development of Semi-Automatic Lathe by using Intelligent Soft Computing Technique
NASA Astrophysics Data System (ADS)
Sakthi, S.; Niresh, J.; Vignesh, K.; Anand Raj, G.
2018-03-01
This paper discusses the enhancement of conventional lathe machine to semi-automated lathe machine by implementing a soft computing method. In the present scenario, lathe machine plays a vital role in the engineering division of manufacturing industry. While the manual lathe machines are economical, the accuracy and efficiency are not up to the mark. On the other hand, CNC machine provide the desired accuracy and efficiency, but requires a huge capital. In order to over come this situation, a semi-automated approach towards the conventional lathe machine is developed by employing stepper motors to the horizontal and vertical drive, that can be controlled by Arduino UNO -microcontroller. Based on the input parameters of the lathe operation the arduino coding is been generated and transferred to the UNO board. Thus upgrading from manual to semi-automatic lathe machines can significantly increase the accuracy and efficiency while, at the same time, keeping a check on investment cost and consequently provide a much needed escalation to the manufacturing industry.
ERIC Educational Resources Information Center
Firdausiah Mansur, Andi Besse; Yusof, Norazah
2013-01-01
Clustering on Social Learning Network still not explored widely, especially when the network focuses on e-learning system. Any conventional methods are not really suitable for the e-learning data. SNA requires content analysis, which involves human intervention and need to be carried out manually. Some of the previous clustering techniques need…
Cleaning of Root Canal System by Different Irrigation Methods.
Tanomaru-Filho, Mário; Miano, Lucas Martinati; Chávez-Andrade, Gisselle Moraima; Torres, Fernanda Ferrari Esteves; Leonardo, Renato de Toledo; Guerreiro-Tanomaru, Juliane Maria
2015-11-01
The aim of this study was to compare the cleaning of main and lateral canals using the irrigation methods: negative pressure irrigation (EndoVac system), passive ultrasonic irrigation (PUI) and manual irrigation (MI). Resin teeth were used. After root canal preparation, four lateral canals were made at 2 and 7 mm from the apex. Root canals were filled with contrast solution and radiographed pre- and post-irrigation using digital radiographic system [radiovisiography (RVG)]. The irrigation protocols were: MI1-manual irrigation [22 G needle at 5 mm short of working length-WL]; MI2-manual irrigation (30G needle at 2 mm short of WL); PUI; EV1-EndoVac (microcannula at 1 mm short of WL); EV2-Endovac (microcannula at 3 mm short of WL). The obtained images, initial (filled with contrast solution) and final (after irrigation) were analyzed by using image tool 3.0 software. Statistical analysis was performed by analysis of variance (ANOVA) and Tukey tests (5% significance level). EV1 and EV2, followed by PUI showed better cleaning capacity than manual irrigation (MI1 and MI2) (p < 0.05). Negative pressure irrigation and PUI promoted better cleaning of main and simulated lateral canals. Conventional manual irrigation technique may promote less root canal cleaning in the apical third. For this reason, the search for other irrigation protocols is important, and EndoVac and PUI are alternatives to contribute to irrigation effectiveness.
2014-01-01
Background Acupuncture and moxibustion have widely been used to treat lateral elbow pain (LEP). A comprehensive systematic review of randomized controlled trials (RCTs) including both English and Chinese databases was conducted to assess the efficacy of acupuncture and moxibustion in the treatment of LEP. Methods Revised STRICTA (2010) criteria were used to appraise the acupuncture procedures, the Cochrane risk of bias tool was used to assess the methodological quality of the studies. A total of 19 RCTs that compared acupuncture and/or moxibustion with sham acupuncture, another form of acupuncture, or conventional treatment were included. Results All studies had at least one domain rated as high risk or uncertain risk of bias in the Cochrane risk of bias tool. Results from three RCTs of moderate quality showed that acupuncture was more effective than sham acupuncture. Results from 10 RCTs of mostly low quality showed that acupuncture or moxibustion was superior or equal to conventional treatment, such as local anesthetic injection, local steroid injection, non-steroidal anti- inflammatory drugs, or ultrasound. There were six low quality RCTs that compared acupuncture and moxibustion combined with manual acupuncture alone, and all showed that acupuncture and moxibustion combined was superior to manual acupuncture alone. Conclusion Moderate quality studies suggest that acupuncture is more effective than sham acupuncture. Interpretations of findings regarding acupuncture vs. conventional treatment, and acupuncture and moxibustion combined vs. manual acupuncture alone are limited by the methodological qualities of these studies. Future studies with improved methodological design are warranted to confirm the efficacy of acupuncture and moxibustion for LEP. PMID:24726029
Plug identification in drainage system using electromagnetic wave
NASA Astrophysics Data System (ADS)
Hijriani, Arifa; Utama, Aji Surya; Boas, Andrianus; Mukti, M. Ridho; Widodo
2017-07-01
The evaluation of drainage system's performance is an important thing to do to prevent flooding. Conventionally the Government evaluates the drainage system by opening one by one the lid of drainage and detects the plug manually. This method is not effective and efficient because this method need many people, much time and relatively expensive. The purpose of this paper is to identify plugs in drainage system in G St. at Bandung Institute of Technology by using electromagnetic wave. Ground Penetrating Radar (GPR) is one of geophysics method that using electromagnetic wave with high frequency. GPR is a non-destructive method with high resolution imaging for shallow depth (˜100m) and relatively cheap. We could identify the plug without opening the lid manually so that we could save much time. GPR's sensitivity is depends on resistivity, magnetic permeability, and permittivity of an object. The result of this research is we could identify the plug on the radargram that observed by a build-up amplitude anomaly.
Boundary segmentation for fluorescence microscopy using steerable filters
NASA Astrophysics Data System (ADS)
Ho, David Joon; Salama, Paul; Dunn, Kenneth W.; Delp, Edward J.
2017-02-01
Fluorescence microscopy is used to image multiple subcellular structures in living cells which are not readily observed using conventional optical microscopy. Moreover, two-photon microscopy is widely used to image structures deeper in tissue. Recent advancement in fluorescence microscopy has enabled the generation of large data sets of images at different depths, times, and spectral channels. Thus, automatic object segmentation is necessary since manual segmentation would be inefficient and biased. However, automatic segmentation is still a challenging problem as regions of interest may not have well defined boundaries as well as non-uniform pixel intensities. This paper describes a method for segmenting tubular structures in fluorescence microscopy images of rat kidney and liver samples using adaptive histogram equalization, foreground/background segmentation, steerable filters to capture directional tendencies, and connected-component analysis. The results from several data sets demonstrate that our method can segment tubular boundaries successfully. Moreover, our method has better performance when compared to other popular image segmentation methods when using ground truth data obtained via manual segmentation.
Role of Noninvasive Hemoglobin Monitoring in Trauma
2015-03-25
spectrophotometry-based monitoring technology (Radical-7® Pulse CO- Oximeter ; Masimo Corp., Irvine, CA) that provides continuous hemoglobin...116(1):65-72. 14. Masimo Corp. Radical-7 signal extraction pulse co- oximeter operator’s manual. Irvine (CA): Masimo Corp.; 2007. 15. Bland JM...method similar to conventional pulse oximetry. Transmitted light is captured by photodiode receptor and analyzed to create an analog signal that, in
Sato, Takaji; Saito, Yoshihiro; Chikuma, Masahiko; Saito, Yutaka; Nagai, Sonoko
2008-03-01
A highly sensitive flow injection fluorometry for the determination of albumin was developed and applied to the determination of albumin in human bronchoalveolar lavage fluids (BALF). This method is based on binding of chromazurol S (CAS) to albumin. The calibration curve was linear in the range of 5-200 microg/ml of albumin. A highly linear correlation (r=0.986) was observed between the albumin level in BALF samples (n=25) determined by the proposed method and by a conventional fluorometric method using CAS (CAS manual method). The IgG interference was lower in the CAS flow injection method than in the CAS manual method. The albumin level in BALF collected from healthy volunteers (n=10) was 58.5+/-13.1 microg/ml. The albumin levels in BALF samples obtained from patients with sarcoidosis and idiopathic pulmonary fibrosis were increased. This finding shows that the determination of albumin levels in BALF samples is useful for investigating lung diseases and that CAS flow injection method is promising in the determination of trace albumin in BALF samples, because it is sensitive and precise.
High-throughput measurement of rice tillers using a conveyor equipped with x-ray computed tomography
NASA Astrophysics Data System (ADS)
Yang, Wanneng; Xu, Xiaochun; Duan, Lingfeng; Luo, Qingming; Chen, Shangbin; Zeng, Shaoqun; Liu, Qian
2011-02-01
Tillering is one of the most important agronomic traits because the number of shoots per plant determines panicle number, a key component of grain yield. The conventional method of counting tillers is still manual. Under the condition of mass measurement, the accuracy and efficiency could be gradually degraded along with fatigue of experienced staff. Thus, manual measurement, including counting and recording, is not only time consuming but also lack objectivity. To automate this process, we developed a high-throughput facility, dubbed high-throughput system for measuring automatically rice tillers (H-SMART), for measuring rice tillers based on a conventional x-ray computed tomography (CT) system and industrial conveyor. Each pot-grown rice plant was delivered into the CT system for scanning via the conveyor equipment. A filtered back-projection algorithm was used to reconstruct the transverse section image of the rice culms. The number of tillers was then automatically extracted by image segmentation. To evaluate the accuracy of this system, three batches of rice at different growth stages (tillering, heading, or filling) were tested, yielding absolute mean absolute errors of 0.22, 0.36, and 0.36, respectively. Subsequently, the complete machine was used under industry conditions to estimate its efficiency, which was 4320 pots per continuous 24 h workday. Thus, the H-SMART could determine the number of tillers of pot-grown rice plants, providing three advantages over the manual tillering method: absence of human disturbance, automation, and high throughput. This facility expands the application of agricultural photonics in plant phenomics.
Yang, Wanneng; Xu, Xiaochun; Duan, Lingfeng; Luo, Qingming; Chen, Shangbin; Zeng, Shaoqun; Liu, Qian
2011-02-01
Tillering is one of the most important agronomic traits because the number of shoots per plant determines panicle number, a key component of grain yield. The conventional method of counting tillers is still manual. Under the condition of mass measurement, the accuracy and efficiency could be gradually degraded along with fatigue of experienced staff. Thus, manual measurement, including counting and recording, is not only time consuming but also lack objectivity. To automate this process, we developed a high-throughput facility, dubbed high-throughput system for measuring automatically rice tillers (H-SMART), for measuring rice tillers based on a conventional x-ray computed tomography (CT) system and industrial conveyor. Each pot-grown rice plant was delivered into the CT system for scanning via the conveyor equipment. A filtered back-projection algorithm was used to reconstruct the transverse section image of the rice culms. The number of tillers was then automatically extracted by image segmentation. To evaluate the accuracy of this system, three batches of rice at different growth stages (tillering, heading, or filling) were tested, yielding absolute mean absolute errors of 0.22, 0.36, and 0.36, respectively. Subsequently, the complete machine was used under industry conditions to estimate its efficiency, which was 4320 pots per continuous 24 h workday. Thus, the H-SMART could determine the number of tillers of pot-grown rice plants, providing three advantages over the manual tillering method: absence of human disturbance, automation, and high throughput. This facility expands the application of agricultural photonics in plant phenomics.
Robotic percutaneous access to the kidney: comparison with standard manual access.
Su, Li-Ming; Stoianovici, Dan; Jarrett, Thomas W; Patriciu, Alexandru; Roberts, William W; Cadeddu, Jeffrey A; Ramakumar, Sanjay; Solomon, Stephen B; Kavoussi, Louis R
2002-09-01
To evaluate the efficiency, accuracy, and safety of robotic percutaneous access to the kidney (PAKY) for percutaneous nephrolithotomy in comparison with conventional manual techniques. We compared the intraoperative access variables (number of access attempts, time to successful access, estimated blood loss, complications) of 23 patients who underwent robotic PAKY with the remote center of motion device (PAKY-RCM) with the same data from a contemporaneous series of 23 patients who underwent conventional manual percutaneous access to the kidney. The PAKY-RCM incorporates a robotic arm and a friction transmission with axial loading system to accurately position and insert a standard 18-gauge needle percutaneously into the kidney. The blood loss during percutaneous access was estimated on a four-point scale (1 = minimal to 4 = large). The color of effluent urine was graded on a four-point scale (1 = clear to 4 = red). The mean target calix width was 13.5 +/- 9.2 mm in the robotic group and 12.2 +/- 4.5 mm in the manual group (P = 0.57). When comparing PAKY-RCM with standard manual techniques, the mean number of attempts was 2.2 +/- 1.6 v 3.2 +/- 2.5 (P = 0.14), time to access was 10.4 +/- 6.5 minutes v 15.1 +/- 8.8 minutes (P = 0.06), estimated blood loss score was 1.3 +/- 0.49 v 1.7 +/- 0.66 (P = 0.14), and color of effluent urine following access was 2.0 +/- 0.90 v 2.1 +/- 0.7 (P = 0.82). The PAKY-RCM was successful in obtaining access in 87% (20 of 23) of cases. The other three patients (13%) required conversion to manual techniques. There were no major intraoperative complications in either group. Robotic PAKY is a feasible, safe, and efficacious method of obtaining renal access for nephrolithotomy. The number of attempts and time to access were comparable to those of standard manual percutaneous access techniques. These findings provide the groundwork for the development of a completely automated robot-assisted percutaneous renal access device.
Student beats the teacher: deep neural networks for lateral ventricles segmentation in brain MR
NASA Astrophysics Data System (ADS)
Ghafoorian, Mohsen; Teuwen, Jonas; Manniesing, Rashindra; Leeuw, Frank-Erik d.; van Ginneken, Bram; Karssemeijer, Nico; Platel, Bram
2018-03-01
Ventricular volume and its progression are known to be linked to several brain diseases such as dementia and schizophrenia. Therefore accurate measurement of ventricle volume is vital for longitudinal studies on these disorders, making automated ventricle segmentation algorithms desirable. In the past few years, deep neural networks have shown to outperform the classical models in many imaging domains. However, the success of deep networks is dependent on manually labeled data sets, which are expensive to acquire especially for higher dimensional data in the medical domain. In this work, we show that deep neural networks can be trained on muchcheaper-to-acquire pseudo-labels (e.g., generated by other automated less accurate methods) and still produce more accurate segmentations compared to the quality of the labels. To show this, we use noisy segmentation labels generated by a conventional region growing algorithm to train a deep network for lateral ventricle segmentation. Then on a large manually annotated test set, we show that the network significantly outperforms the conventional region growing algorithm which was used to produce the training labels for the network. Our experiments report a Dice Similarity Coefficient (DSC) of 0.874 for the trained network compared to 0.754 for the conventional region growing algorithm (p < 0.001).
Improved BC method of Compomat G4 for expression of BCs twice from whole blood in top and top bags.
Deng, Xiao-Yan; Wu, Xiao-Man; Zhao, Yang; Luo, Hong; Jia, Hong-Yun; Wang, Zhong-Ying; He, Bo; Wang, Chuan-Xi
2011-05-01
The aim of this paper was to evaluate an improved buffy coat (BC) method of Compomat G4 for automated expression of BCs twice from whole blood (WB) in top and top (T&T) bags. WB was separated using hard spin centrifugation (2,988g, 10 min) into layers of blood components by specific gravity, and different components were subsequently expressed into satellite bags in the T&T system using the manual BC method, the conventional BC method of G4, and our improved BC method of G4. In the improved BC method, an accessorial device we have named a 'gravity press' was designed and installed on the top flat of G4 to produce gravitational pressure on the plasma bag so as to exclude air and some of plasma to the upper compartment of the slide after BCs were expressed for the first time. The residual BCs in the upper compartment were expressed a second time by extending the upper press once more. All of the pooled BCs were centrifuged by soft spin (402g, 10 min) and upper platelet-rich supernatant was manually expressed into a platelet container by the plasma extractor. In vitro studies of blood components and pooled platelet concentrates (PCs) revealed no significant differences in BC blood components and platelet recovery of pooled platelets (61 ± 9 vs. 60 ± 7%, n = 12, p > 0.05) between the improved BC method and the conventional BC method; all components met our specifications for blood products. We suggest that the new BC method for use of T&T bags may improve the collection of BCs.
Onder, Devrim; Sarioglu, Sulen; Karacali, Bilge
2013-04-01
Quasi-supervised learning is a statistical learning algorithm that contrasts two datasets by computing estimate for the posterior probability of each sample in either dataset. This method has not been applied to histopathological images before. The purpose of this study is to evaluate the performance of the method to identify colorectal tissues with or without adenocarcinoma. Light microscopic digital images from histopathological sections were obtained from 30 colorectal radical surgery materials including adenocarcinoma and non-neoplastic regions. The texture features were extracted by using local histograms and co-occurrence matrices. The quasi-supervised learning algorithm operates on two datasets, one containing samples of normal tissues labelled only indirectly, and the other containing an unlabeled collection of samples of both normal and cancer tissues. As such, the algorithm eliminates the need for manually labelled samples of normal and cancer tissues for conventional supervised learning and significantly reduces the expert intervention. Several texture feature vector datasets corresponding to different extraction parameters were tested within the proposed framework. The Independent Component Analysis dimensionality reduction approach was also identified as the one improving the labelling performance evaluated in this series. In this series, the proposed method was applied to the dataset of 22,080 vectors with reduced dimensionality 119 from 132. Regions containing cancer tissue could be identified accurately having false and true positive rates up to 19% and 88% respectively without using manually labelled ground-truth datasets in a quasi-supervised strategy. The resulting labelling performances were compared to that of a conventional powerful supervised classifier using manually labelled ground-truth data. The supervised classifier results were calculated as 3.5% and 95% for the same case. The results in this series in comparison with the benchmark classifier, suggest that quasi-supervised image texture labelling may be a useful method in the analysis and classification of pathological slides but further study is required to improve the results. Copyright © 2013 Elsevier Ltd. All rights reserved.
Fetal head detection and measurement in ultrasound images by an iterative randomized Hough transform
NASA Astrophysics Data System (ADS)
Lu, Wei; Tan, Jinglu; Floyd, Randall C.
2004-05-01
This paper describes an automatic method for measuring the biparietal diameter (BPD) and head circumference (HC) in ultrasound fetal images. A total of 217 ultrasound images were segmented by using a K-Mean classifier, and the head skull was detected in 214 of the 217 cases by an iterative randomized Hough transform developed for detection of incomplete curves in images with strong noise without user intervention. The automatic measurements were compared with conventional manual measurements by sonographers and a trained panel. The inter-run variations and differences between the automatic and conventional measurements were small compared with published inter-observer variations. The results showed that the automated measurements were as reliable as the expert measurements and more consistent. This method has great potential in clinical applications.
Similarity estimation for reference image retrieval in mammograms using convolutional neural network
NASA Astrophysics Data System (ADS)
Muramatsu, Chisako; Higuchi, Shunichi; Morita, Takako; Oiwa, Mikinao; Fujita, Hiroshi
2018-02-01
Periodic breast cancer screening with mammography is considered effective in decreasing breast cancer mortality. For screening programs to be successful, an intelligent image analytic system may support radiologists' efficient image interpretation. In our previous studies, we have investigated image retrieval schemes for diagnostic references of breast lesions on mammograms and ultrasound images. Using a machine learning method, reliable similarity measures that agree with radiologists' similarity were determined and relevant images could be retrieved. However, our previous method includes a feature extraction step, in which hand crafted features were determined based on manual outlines of the masses. Obtaining the manual outlines of masses is not practical in clinical practice and such data would be operator-dependent. In this study, we investigated a similarity estimation scheme using a convolutional neural network (CNN) to skip such procedure and to determine data-driven similarity scores. By using CNN as feature extractor, in which extracted features were employed in determination of similarity measures with a conventional 3-layered neural network, the determined similarity measures were correlated well with the subjective ratings and the precision of retrieving diagnostically relevant images was comparable with that of the conventional method using handcrafted features. By using CNN for determination of similarity measure directly, the result was also comparable. By optimizing the network parameters, results may be further improved. The proposed method has a potential usefulness in determination of similarity measure without precise lesion outlines for retrieval of similar mass images on mammograms.
Unsupervised Ensemble Anomaly Detection Using Time-Periodic Packet Sampling
NASA Astrophysics Data System (ADS)
Uchida, Masato; Nawata, Shuichi; Gu, Yu; Tsuru, Masato; Oie, Yuji
We propose an anomaly detection method for finding patterns in network traffic that do not conform to legitimate (i.e., normal) behavior. The proposed method trains a baseline model describing the normal behavior of network traffic without using manually labeled traffic data. The trained baseline model is used as the basis for comparison with the audit network traffic. This anomaly detection works in an unsupervised manner through the use of time-periodic packet sampling, which is used in a manner that differs from its intended purpose — the lossy nature of packet sampling is used to extract normal packets from the unlabeled original traffic data. Evaluation using actual traffic traces showed that the proposed method has false positive and false negative rates in the detection of anomalies regarding TCP SYN packets comparable to those of a conventional method that uses manually labeled traffic data to train the baseline model. Performance variation due to the probabilistic nature of sampled traffic data is mitigated by using ensemble anomaly detection that collectively exploits multiple baseline models in parallel. Alarm sensitivity is adjusted for the intended use by using maximum- and minimum-based anomaly detection that effectively take advantage of the performance variations among the multiple baseline models. Testing using actual traffic traces showed that the proposed anomaly detection method performs as well as one using manually labeled traffic data and better than one using randomly sampled (unlabeled) traffic data.
NASA Astrophysics Data System (ADS)
Kurnia, H.; Noerhadi, N. A. I.
2017-08-01
Three-dimensional digital study models were introduced following advances in digital technology. This study was carried out to assess the reliability of digital study models scanned by a laser scanning device newly assembled. The aim of this study was to compare the digital study models and conventional models. Twelve sets of dental impressions were taken from patients with mild-to-moderate crowding. The impressions were taken twice, one with alginate and the other with polyvinylsiloxane. The alginate impressions were made into conventional models, and the polyvinylsiloxane impressions were scanned to produce digital models. The mesiodistal tooth width and Little’s irregularity index (LII) were measured manually with digital calipers on the conventional models and digitally on the digital study models. Bolton analysis was performed on each study models. Each method was carried out twice to check for intra-observer variability. The reproducibility (comparison of the methods) was assessed using independent-sample t-tests. The mesiodistal tooth width between conventional and digital models did not significantly differ (p > 0.05). Independent-sample t-tests did not identify statistically significant differences for Bolton analysis and LII (p = 0.603 for Bolton and p = 0894 for LII). The measurements of the digital study models are as accurate as those of the conventional models.
Lee, Sungsil; Lim, Hwan Sub; Park, Jungyong; Kim, Hyon Suk
2009-04-01
In the diagnosis of atopic diseases, allergen detection is a crucial step. Multiple allergen simultaneous test-chemiluminescent assay (MAST-CLA) is a simple and noninvasive method for in vitro screening of allergen-specific IgE antibodies. The Korean Inhalant Panel test on 20 patients and Food Panel test on 19 patients were performed using the conventional manual MAST-CLA kit and the new automated MAST-CLA method (automated AP720S system for the Optigen Assay; Hitachi Chemical Diagnostics, Inc., USA) simultaneously. The results were evaluated for positive reactivity and concordance. The results of inhalant panel gave a relatively higher class level result than the food panel. The 8 patients out of 20 (40%) of the inhalation panel, and 9 patients out of 18 (47.4%) of the food panel showed 100% concordance between the 2 systems. Eighteen patients (90%) of the Inhalation Panel and sixteen patients (84.2%) of the Food Panel showed more than 91% concordance. These results suggest that the MAST-CLA assay using the new, automated AP720S analyzer performs well, showing a high concordance rate with conventional MAST-CLA. Compared to manual MAST-CLA, the automated AP720S system has a shorter assay time and uses a smaller serum volume (500 microl) along with other conveniences.
Surface smoothness: cartilage biomarkers for knee OA beyond the radiologist
NASA Astrophysics Data System (ADS)
Tummala, Sudhakar; Dam, Erik B.
2010-03-01
Fully automatic imaging biomarkers may allow quantification of patho-physiological processes that a radiologist would not be able to assess reliably. This can introduce new insight but is problematic to validate due to lack of meaningful ground truth expert measurements. Rather than quantification accuracy, such novel markers must therefore be validated against clinically meaningful end-goals such as the ability to allow correct diagnosis. We present a method for automatic cartilage surface smoothness quantification in the knee joint. The quantification is based on a curvature flow method used on tibial and femoral cartilage compartments resulting from an automatic segmentation scheme. These smoothness estimates are validated for their ability to diagnose osteoarthritis and compared to smoothness estimates based on manual expert segmentations and to conventional cartilage volume quantification. We demonstrate that the fully automatic markers eliminate the time required for radiologist annotations, and in addition provide a diagnostic marker superior to the evaluated semi-manual markers.
Augmented reality-based electrode guidance system for reliable electroencephalography.
Song, Chanho; Jeon, Sangseo; Lee, Seongpung; Ha, Ho-Gun; Kim, Jonghyun; Hong, Jaesung
2018-05-24
In longitudinal electroencephalography (EEG) studies, repeatable electrode positioning is essential for reliable EEG assessment. Conventional methods use anatomical landmarks as fiducial locations for the electrode placement. Since the landmarks are manually identified, the EEG assessment is inevitably unreliable because of individual variations among the subjects and the examiners. To overcome this unreliability, an augmented reality (AR) visualization-based electrode guidance system was proposed. The proposed electrode guidance system is based on AR visualization to replace the manual electrode positioning. After scanning and registration of the facial surface of a subject by an RGB-D camera, the AR of the initial electrode positions as reference positions is overlapped with the current electrode positions in real time. Thus, it can guide the position of the subsequently placed electrodes with high repeatability. The experimental results with the phantom show that the repeatability of the electrode positioning was improved compared to that of the conventional 10-20 positioning system. The proposed AR guidance system improves the electrode positioning performance with a cost-effective system, which uses only RGB-D camera. This system can be used as an alternative to the international 10-20 system.
Dreizin, David; Bodanapally, Uttam K; Neerchal, Nagaraj; Tirada, Nikki; Patlas, Michael; Herskovits, Edward
2016-11-01
Manually segmented traumatic pelvic hematoma volumes are strongly predictive of active bleeding at conventional angiography, but the method is time intensive, limiting its clinical applicability. We compared volumetric analysis using semi-automated region growing segmentation to manual segmentation and diameter-based size estimates in patients with pelvic hematomas after blunt pelvic trauma. A 14-patient cohort was selected in an anonymous randomized fashion from a dataset of patients with pelvic binders at MDCT, collected retrospectively as part of a HIPAA-compliant IRB-approved study from January 2008 to December 2013. To evaluate intermethod differences, one reader (R1) performed three volume measurements using the manual technique and three volume measurements using the semi-automated technique. To evaluate interobserver differences for semi-automated segmentation, a second reader (R2) performed three semi-automated measurements. One-way analysis of variance was used to compare differences in mean volumes. Time effort was also compared. Correlation between the two methods as well as two shorthand appraisals (greatest diameter, and the ABC/2 method for estimating ellipsoid volumes) was assessed with Spearman's rho (r). Intraobserver variability was lower for semi-automated compared to manual segmentation, with standard deviations ranging between ±5-32 mL and ±17-84 mL, respectively (p = 0.0003). There was no significant difference in mean volumes between the two readers' semi-automated measurements (p = 0.83); however, means were lower for the semi-automated compared with the manual technique (manual: mean and SD 309.6 ± 139 mL; R1 semi-auto: 229.6 ± 88.2 mL, p = 0.004; R2 semi-auto: 243.79 ± 99.7 mL, p = 0.021). Despite differences in means, the correlation between the two methods was very strong and highly significant (r = 0.91, p < 0.001). Correlations with diameter-based methods were only moderate and nonsignificant. Mean semi-automated segmentation time effort was 2 min and 6 s and 2 min and 35 s for R1 and R2, respectively, vs. 22 min and 8 s for manual segmentation. Semi-automated pelvic hematoma volumes correlate strongly with manually segmented volumes. Since semi-automated segmentation can be performed reliably and efficiently, volumetric analysis of traumatic pelvic hematomas is potentially valuable at the point-of-care.
Soós, Sándor Árpád; Jeszenői, Norbert; Darvas, Katalin; Harsányi, László
2016-11-08
Despite their worldwide popularity the question of using non-conventional treatments is a source of controversy among medical professionals. Although these methods may have potential benefits it presents a problem when patients use non-conventional treatments in the perioperative period without informing their attending physician about it and this may cause adverse events and complications. To prevent this, physicians need to have a profound knowledge about non-conventional treatments. An anonymous questionnaire was distributed among surgeons and anaesthesiologists working in Hungarian university clinics and in selected city or county hospitals. Questionnaires were distributed by post, online or in person. Altogether 258 questionnaires were received from 22 clinical and hospital departments. Anaesthesiologists and surgeons use reflexology, Traditional Chinese Medicine, herbal medicine and manual therapy most frequently in their clinical practice. Traditional Chinese Medicine was considered to be the most scientifically sound method, while homeopathy was perceived as the least well-grounded method. Neural therapy was the least well-known method among our subjects. Among the subjects of our survey only 3.1 % of perioperative care physicians had some qualifications in non-conventional medicine, 12.4 % considered themselves to be well-informed in this topic and 48.4 % would like to study some complementary method. Women were significantly more interested in alternative treatments than men, p = 0.001427; OR: 2.2765. Anaesthesiologists would be significantly more willing to learn non-conventional methods than surgeons. 86.4 % of the participants thought that non-conventional treatments should be evaluated from the point of view of evidence. Both surgeons and anaesthesiologists accept the application of integrative medicine and they also approve of the idea of teaching these methods at universities. According to perioperative care physicians, non-conventional methods should be evaluated based on evidence. They also expressed a willingness to learn about those treatments that meet the criteria of evidence and apply these in their clinical practice.
Applications of "Integrated Data Viewer'' (IDV) in the classroom
NASA Astrophysics Data System (ADS)
Nogueira, R.; Cutrim, E. M.
2006-06-01
Conventionally, weather products utilized in synoptic meteorology reduce phenomena occurring in four dimensions to a 2-dimensional form. This constitutes a road-block for non-atmospheric-science majors who need to take meteorology as a non-mathematical and complementary course to their major programs. This research examines the use of Integrated Data Viewer-IDV as a teaching tool, as it allows a 4-dimensional representation of weather products. IDV was tested in the teaching of synoptic meteorology, weather analysis, and weather map interpretation to non-science students in the laboratory sessions of an introductory meteorology class at Western Michigan University. Comparison of student exam scores according to the laboratory teaching techniques, i.e., traditional lab manual and IDV was performed for short- and long-term learning. Results of the statistical analysis show that the Fall 2004 students in the IDV-based lab session retained learning. However, in the Spring 2005 the exam scores did not reflect retention in learning when compared with IDV-based and MANUAL-based lab scores (short term learning, i.e., exam taken one week after the lab exercise). Testing the long-term learning, seven weeks between the two exams in the Spring 2005, show no statistically significant difference between IDV-based group scores and MANUAL-based group scores. However, the IDV group obtained exam score average slightly higher than the MANUAL group. Statistical testing of the principal hypothesis in this study, leads to the conclusion that the IDV-based method did not prove to be a better teaching tool than the traditional paper-based method. Future studies could potentially find significant differences in the effectiveness of both manual and IDV methods if the conditions had been more controlled. That is, students in the control group should not be exposed to the weather analysis using IDV during lecture.
NASA Technical Reports Server (NTRS)
Nakazawa, Shohei
1989-01-01
The internal structure is discussed of the MHOST finite element program designed for 3-D inelastic analysis of gas turbine hot section components. The computer code is the first implementation of the mixed iterative solution strategy for improved efficiency and accuracy over the conventional finite element method. The control structure of the program is covered along with the data storage scheme and the memory allocation procedure and the file handling facilities including the read and/or write sequences.
Adragão, Pedro Pulido; Cavaco, Diogo; Ferreira, António Miguel; Costa, Francisco Moscoso; Parreira, Leonor; Carmo, Pedro; Morgado, Francisco Bello; Santos, Katya Reis; Santos, Pedro Galvão; Carvalho, Maria Salomé; Durazzo, Anai; Marques, Hugo; Gonçalves, Pedro Araújo; Raposo, Luís; Mendes, Miguel
2016-03-01
Whether or not the potential advantages of using a magnetic navigation system (MNS) translate into improved outcomes in patients undergoing atrial fibrillation (AF) ablation is a question that remains unanswered. In this observational registry study, we used propensity-score matching to compare the outcomes of patients with symptomatic drug-refractory AF who underwent catheter ablation using MNS with the outcomes of those who underwent catheter ablation using conventional manual navigation. Among 1,035 eligible patients, 287 patients in each group had similar propensity scores and were included in the analysis. The primary efficacy outcome was the rate of AF relapse after a 3-month blanking period. At a mean follow-up of 2.6 ± 1.5 years, AF ablation with MNS was associated with a similar risk of AF relapse as compared with manual navigation (18.4% per year and 22.3% per year, respectively; hazard ratio 0.81, 95% CI 0.63-1.05; P = 0.108). Major complications occurred in two patients (0.7%) using MNS, and in six patients (2.1%) undergoing manually navigated ablation (P = 0.286). Fluoroscopy times were 21 ± 10 minutes in the manual navigation group, and 12 ± 9 minutes in the MNS group (P < 0.001), whereas total procedure times were 152 ± 52 minutes and 213 ± 58 minutes, respectively (P < 0.001). In this propensity-score matched comparison, magnetic navigation and conventional manual AF ablations seem to have similar relapse rates and a similar risk of complications. AF ablations with magnetic navigation take longer to perform but expose patients to significantly shorter fluoroscopy times. © 2015 Wiley Periodicals, Inc.
Trnková, Petra; Baltas, Dimos; Karabis, Andreas; Stock, Markus; Dimopoulos, Johannes; Georg, Dietmar; Pötter, Richard; Kirisits, Christian
2010-12-01
The purpose of this study was to compare two inverse planning algorithms for cervical cancer brachytherapy and a conventional manual treatment planning according to the MUW (Medical University of Vienna) protocol. For 20 patients, manually optimized, and, inversely optimized treatment plans with Hybrid Inverse treatment Planning and Optimization (HIPO) and with Inverse Planning Simulated Annealing (IPSA) were created. Dosimetric parameters, absolute volumes of normal tissue receiving reference doses, absolute loading times of tandem, ring and interstitial needles, Paddick and COIN conformity indices were evaluated. HIPO was able to achieve a similar dose distribution to manual planning with the restriction of high dose regions. It reduced the loading time of needles and the overall treatment time. The values of both conformity indices were the lowest. IPSA was able to achieve acceptable dosimetric results. However, it overloaded the needles. This resulted in high dose regions located in the normal tissue. The Paddick index for the volume of two times prescribed dose was outstandingly low. HIPO can produce clinically acceptable treatment plans with the elimination of high dose regions in normal tissue. Compared to IPSA, it is an inverse optimization method which takes into account current clinical experience gained from manual treatment planning.
General Drafting. Technical Manual.
ERIC Educational Resources Information Center
Department of the Army, Washington, DC.
The manual provides instructional guidance and reference material in the principles and procedures of general drafting and constitutes the primary study text for personnel in drafting as a military occupational specialty. Included is information on drafting equipment and its use; line weights, conventions and formats; lettering; engineering charts…
NASA Astrophysics Data System (ADS)
Fujita, Yusuke; Mitani, Yoshihiro; Hamamoto, Yoshihiko; Segawa, Makoto; Terai, Shuji; Sakaida, Isao
2017-03-01
Ultrasound imaging is a popular and non-invasive tool used in the diagnoses of liver disease. Cirrhosis is a chronic liver disease and it can advance to liver cancer. Early detection and appropriate treatment are crucial to prevent liver cancer. However, ultrasound image analysis is very challenging, because of the low signal-to-noise ratio of ultrasound images. To achieve the higher classification performance, selection of training regions of interest (ROIs) is very important that effect to classification accuracy. The purpose of our study is cirrhosis detection with high accuracy using liver ultrasound images. In our previous works, training ROI selection by MILBoost and multiple-ROI classification based on the product rule had been proposed, to achieve high classification performance. In this article, we propose self-training method to select training ROIs effectively. Evaluation experiments were performed to evaluate effect of self-training, using manually selected ROIs and also automatically selected ROIs. Experimental results show that self-training for manually selected ROIs achieved higher classification performance than other approaches, including our conventional methods. The manually ROI definition and sample selection are important to improve classification accuracy in cirrhosis detection using ultrasound images.
Schödel, Petra; Proescholdt, Martin; Brawanski, Alexander; Bele, Sylvia; Schebesch, Karl-Michael
2012-04-01
Burr-hole trephine and insertion of an external ventricular drainage (EVD) is a common procedure in neurosurgical practice. In critically ill patients, the transport to the operating room, OR represents a major risk. Thus, the burr-hole trephine and implantation of an EVD is frequently performed on the Intensive Care Unit (ICU). Since 2004, we have applied two different procedures: the conventional method with a mechanical compressed air or an electric drill, and an alternative method with a manual twist drill, including fixation of the EVD in a skull screw (Bolt Kit, Raumedic AG, Germany). This study was designed to evaluate the outcome of both surgical procedures. In this retrospective analysis we included 166 consecutive patients with acute hydrocephalus due to intracranial hemorrhage that had been operated at our neurosurgical ICU in a six years interval. We reviewed the charts for gender and age, kind of surgical procedure, cerebrospinal fluid (CSF)-infections, duration of drainage, attempts of insertions, wound infections, misplacement rate, post-surgical hemorrhages, revisions, comorbidities and shunt-dependency. In 122 patients we applied the Bolt Kit System, in 44 patients the conventional method was performed. We found a significantly lower rate of CSF-infections and significantly fewer attempts of insertions in the Bolt Kit group (p = 0.002 and p = 0.001, respectively). The rate of wound infections, misplacement, revisions, shunt-dependency and the post-surgical hemorrhages did not differ significantly. Our data indicate that the manual drill and the skull screw are safe and feasible tools in the treatment of acute hydrocephalus. Presumably, the direct skin contact is causative for the higher rate of CSF-infections when the conventional method is performed. The skull screw guides the EVD into the ventricle without skin contact. The lower number of insertions needed may be due to the fact that the skull screw allows just one trajectory for the insertion of the EVD.
Library Binding Manual. Revised Edition.
ERIC Educational Resources Information Center
Lakhanpal, S. K.
This procedural manual is designed to be used in bindery sections in public, university and special libraries. It briefly discusses these general matters: administrative control; selection of a binder; when and what to bind; conventional binding; routines; missing issues; schedule for shipments; temporary binding; rare books, maps and newspapers;…
Effects of 99mTc-TRODAT-1 drug template on image quantitative analysis
Yang, Bang-Hung; Chou, Yuan-Hwa; Wang, Shyh-Jen; Chen, Jyh-Cheng
2018-01-01
99mTc-TRODAT-1 is a type of drug that can bind to dopamine transporters in living organisms and is often used in SPCT imaging for observation of changes in the activity uptake of dopamine in the striatum. Therefore, it is currently widely used in studies on clinical diagnosis of Parkinson’s disease (PD) and movement-related disorders. In conventional 99mTc-TRODAT-1 SPECT image evaluation, visual inspection or manual selection of ROI for semiquantitative analysis is mainly used to observe and evaluate the degree of striatal defects. However, these methods are dependent on the subjective opinions of observers, which lead to human errors, have shortcomings such as long duration, increased effort, and have low reproducibility. To solve this problem, this study aimed to establish an automatic semiquantitative analytical method for 99mTc-TRODAT-1. This method combines three drug templates (one built-in SPECT template in SPM software and two self-generated MRI-based and HMPAO-based TRODAT-1 templates) for the semiquantitative analysis of the striatal phantom and clinical images. At the same time, the results of automatic analysis of the three templates were compared with results from a conventional manual analysis for examining the feasibility of automatic analysis and the effects of drug templates on automatic semiquantitative analysis results. After comparison, it was found that the MRI-based TRODAT-1 template generated from MRI images is the most suitable template for 99mTc-TRODAT-1 automatic semiquantitative analysis. PMID:29543874
A hydraulically driven colonoscope.
Coleman, Stuart A; Tapia-Siles, Silvia C; Pakleppa, Markus; Vorstius, Jan B; Keatch, Robert P; Tang, Benjie; Cuschieri, Alfred
2016-10-01
Conventional colonoscopy requires a high degree of operator skill and is often painful for the patient. We present a preliminary feasibility study of an alternative approach where a self-propelled colonoscope is hydraulically driven through the colon. A hydraulic colonoscope which could be controlled manually or automatically was developed and assessed in a test bed modelled on the anatomy of the human colon. A conventional colonoscope was used by an experienced colonoscopist in the same test bed for comparison. Pressures and forces on the colon were measured during the test. The hydraulic colonoscope was able to successfully advance through the test bed in a comparable time to the conventional colonoscope. The hydraulic colonoscope reduces measured loads on artificial mesenteries, but increases intraluminal pressure compared to the colonoscope. Both manual and automatically controlled modes were able to successfully advance the hydraulic colonoscope through the colon. However, the automatic controller mode required lower pressures than manual control, but took longer to reach the caecum. The hydraulic colonoscope appears to be a viable device for further development as forces and pressures observed during use are comparable to those used in current clinical practice.
Fully automatic multi-atlas segmentation of CTA for partial volume correction in cardiac SPECT/CT
NASA Astrophysics Data System (ADS)
Liu, Qingyi; Mohy-ud-Din, Hassan; Boutagy, Nabil E.; Jiang, Mingyan; Ren, Silin; Stendahl, John C.; Sinusas, Albert J.; Liu, Chi
2017-05-01
Anatomical-based partial volume correction (PVC) has been shown to improve image quality and quantitative accuracy in cardiac SPECT/CT. However, this method requires manual segmentation of various organs from contrast-enhanced computed tomography angiography (CTA) data. In order to achieve fully automatic CTA segmentation for clinical translation, we investigated the most common multi-atlas segmentation methods. We also modified the multi-atlas segmentation method by introducing a novel label fusion algorithm for multiple organ segmentation to eliminate overlap and gap voxels. To evaluate our proposed automatic segmentation, eight canine 99mTc-labeled red blood cell SPECT/CT datasets that incorporated PVC were analyzed, using the leave-one-out approach. The Dice similarity coefficient of each organ was computed. Compared to the conventional label fusion method, our proposed label fusion method effectively eliminated gaps and overlaps and improved the CTA segmentation accuracy. The anatomical-based PVC of cardiac SPECT images with automatic multi-atlas segmentation provided consistent image quality and quantitative estimation of intramyocardial blood volume, as compared to those derived using manual segmentation. In conclusion, our proposed automatic multi-atlas segmentation method of CTAs is feasible, practical, and facilitates anatomical-based PVC of cardiac SPECT/CT images.
Wongsritrang, Krongthong; Fueangkamloon, Sumet
2013-09-01
To compare the clinical outcomes and determine the difference in therapeutic pressure between Automatic positive airway pressure (APAP) and polysomnography manual titration. Fifty patients of obstructive sleep apnea (OSA), moderate to severe cases, were randomized into two groups of intervention: 95-percentile pressure derived from APAP titration and an optimal pressure derived from manual titration. Clinical outcomes were assessed before and after four weeks. The average 95-percentile pressure derived from APAP titration was 11.7 +/- 0.3 cmH2O with median mask leak 1.3 L/min. The average optimal pressure derived from manual titration was 8.2 +/- 0.3 cmH2O. Pearson correlation analysis showed weak positive correlation (r = 0.336, p = 0.017). The Epworth Sleepiness Score (ESS), Quality of life tests: PSQI (Pittsburg Sleep Quality Index), and SF-36 (Medical Outcomes Study 36-Item Short-Form Health Survey) were improved significantly in both groups, but there were no statistical significant differences between groups. An APAP titration is an effective method of pressure determination for conventional CPAP therapy and shows no difference in clinical outcomes comparing the standard titration.
This manual highlights the project constraints and concerns, and includes detailed design calculations and system schematics. The plant is based on engineering design principles and practices, previous pilot plant design experiences, and professional experiences and may serve as ...
NASA Astrophysics Data System (ADS)
Park, Seyoun; Robinson, Adam; Quon, Harry; Kiess, Ana P.; Shen, Colette; Wong, John; Plishker, William; Shekhar, Raj; Lee, Junghoon
2016-03-01
In this paper, we propose a CT-CBCT registration method to accurately predict the tumor volume change based on daily cone-beam CTs (CBCTs) during radiotherapy. CBCT is commonly used to reduce patient setup error during radiotherapy, but its poor image quality impedes accurate monitoring of anatomical changes. Although physician's contours drawn on the planning CT can be automatically propagated to daily CBCTs by deformable image registration (DIR), artifacts in CBCT often cause undesirable errors. To improve the accuracy of the registration-based segmentation, we developed a DIR method that iteratively corrects CBCT intensities by local histogram matching. Three popular DIR algorithms (B-spline, demons, and optical flow) with the intensity correction were implemented on a graphics processing unit for efficient computation. We evaluated their performances on six head and neck (HN) cancer cases. For each case, four trained scientists manually contoured the nodal gross tumor volume (GTV) on the planning CT and every other fraction CBCTs to which the propagated GTV contours by DIR were compared. The performance was also compared with commercial image registration software based on conventional mutual information (MI), VelocityAI (Varian Medical Systems Inc.). The volume differences (mean±std in cc) between the average of the manual segmentations and automatic segmentations are 3.70+/-2.30 (B-spline), 1.25+/-1.78 (demons), 0.93+/-1.14 (optical flow), and 4.39+/-3.86 (VelocityAI). The proposed method significantly reduced the estimation error by 9% (B-spline), 38% (demons), and 51% (optical flow) over the results using VelocityAI. Although demonstrated only on HN nodal GTVs, the results imply that the proposed method can produce improved segmentation of other critical structures over conventional methods.
Epidermal segmentation in high-definition optical coherence tomography.
Li, Annan; Cheng, Jun; Yow, Ai Ping; Wall, Carolin; Wong, Damon Wing Kee; Tey, Hong Liang; Liu, Jiang
2015-01-01
Epidermis segmentation is a crucial step in many dermatological applications. Recently, high-definition optical coherence tomography (HD-OCT) has been developed and applied to imaging subsurface skin tissues. In this paper, a novel epidermis segmentation method using HD-OCT is proposed in which the epidermis is segmented by 3 steps: the weighted least square-based pre-processing, the graph-based skin surface detection and the local integral projection-based dermal-epidermal junction detection respectively. Using a dataset of five 3D volumes, we found that this method correlates well with the conventional method of manually marking out the epidermis. This method can therefore serve to effectively and rapidly delineate the epidermis for study and clinical management of skin diseases.
Olesen, Alexander Neergaard; Christensen, Julie A E; Sorensen, Helge B D; Jennum, Poul J
2016-08-01
Reducing the number of recording modalities for sleep staging research can benefit both researchers and patients, under the condition that they provide as accurate results as conventional systems. This paper investigates the possibility of exploiting the multisource nature of the electrooculography (EOG) signals by presenting a method for automatic sleep staging using the complete ensemble empirical mode decomposition with adaptive noise algorithm, and a random forest classifier. It achieves a high overall accuracy of 82% and a Cohen's kappa of 0.74 indicating substantial agreement between automatic and manual scoring.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, S; Robinson, A; Kiess, A
2015-06-15
Purpose: The purpose of this study is to develop an accurate and effective technique to predict and monitor volume changes of the tumor and organs at risk (OARs) from daily cone-beam CTs (CBCTs). Methods: While CBCT is typically used to minimize the patient setup error, its poor image quality impedes accurate monitoring of daily anatomical changes in radiotherapy. Reconstruction artifacts in CBCT often cause undesirable errors in registration-based contour propagation from the planning CT, a conventional way to estimate anatomical changes. To improve the registration and segmentation accuracy, we developed a new deformable image registration (DIR) that iteratively corrects CBCTmore » intensities using slice-based histogram matching during the registration process. Three popular DIR algorithms (hierarchical B-spline, demons, optical flow) augmented by the intensity correction were implemented on a graphics processing unit for efficient computation, and their performances were evaluated on six head and neck (HN) cancer cases. Four trained scientists manually contoured nodal gross tumor volume (GTV) on the planning CT and every other fraction CBCTs for each case, to which the propagated GTV contours by DIR were compared. The performance was also compared with commercial software, VelocityAI (Varian Medical Systems Inc.). Results: Manual contouring showed significant variations, [-76, +141]% from the mean of all four sets of contours. The volume differences (mean±std in cc) between the average manual segmentation and four automatic segmentations are 3.70±2.30(B-spline), 1.25±1.78(demons), 0.93±1.14(optical flow), and 4.39±3.86 (VelocityAI). In comparison to the average volume of the manual segmentations, the proposed approach significantly reduced the estimation error by 9%(B-spline), 38%(demons), and 51%(optical flow) over the conventional mutual information based method (VelocityAI). Conclusion: The proposed CT-CBCT registration with local CBCT intensity correction can accurately predict the tumor volume change with reduced errors. Although demonstrated only on HN nodal GTVs, the results imply improved accuracy for other critical structures. This work was supported by NIH/NCI under grant R42CA137886.« less
Santos-Couto-Paz, Clarissa C; Teixeira-Salmela, Luci F; Tierra-Criollo, Carlos J
2013-01-01
Mental practice (MP) is a cognitive strategy which may improve the acquisition of motor skills and functional performance of athletes and individuals with neurological injuries. To determine whether an individualized, specific functional task-oriented MP, when added to conventional physical therapy (PT), promoted better learning of motor skills in daily functions in individuals with chronic stroke (13 ± 6.5 months post-stroke). Nine individuals with stable mild and moderate upper limb impairments participated, by employing an A1-B-A2 single-case design. Phases A1 and A2 included one month of conventional PT, and phase B the addition of MP training to PT. The motor activity log (MAL-Brazil) was used to assess the amount of use (AOU) and quality of movement (QOM) of the paretic upper limb; the revised motor imagery questionnaire (MIQ-RS) to assess the abilities in kinesthetic and visual motor imagery; the Minnesota manual dexterity test to assess manual dexterity; and gait speed to assess mobility. After phase A1, no significant changes were observed for any of the outcome measures. However, after phase B, significant improvements were observed for the MAL, AOU and QOM scores (p<0.0001), and MIQ-RS kinesthetic and visual scores (p=0.003; p=0.007, respectively). The significant gains in manual dexterity (p=0.002) and gait speed (p=0.019) were maintained after phase A2. Specific functional task-oriented MP, when added to conventional PT, led to improvements in motor imagery abilities combined with increases in the AOU and QOM in daily functions, manual dexterity, and gait speed.
Blueprint for Success. . . A Manual for Conventions, Conferences, Seminars and Workshops.
ERIC Educational Resources Information Center
Jax, John J., Ed.
Intended to provide the guidance needed for consistent and viable annual conference planning, this manual explains how to organize and plan for a successful and profitable conference, how to determine the responsibilities and duties of conference planners and coordinators, and how to plan for specific conference events. The responsibilities of a…
Laser Communications and Fiber Optics Lab Manual. High-Technology Training Module.
ERIC Educational Resources Information Center
Biddick, Robert
This laboratory training manual on laser communications and fiber optics may be used in a general technology-communications course for ninth graders. Upon completion of this exercise, students achieve the following goals: match concepts with laser communication system parts; explain advantages of fiber optic cable over conventional copper wire;…
A Minimal Path Searching Approach for Active Shape Model (ASM)-based Segmentation of the Lung.
Guo, Shengwen; Fei, Baowei
2009-03-27
We are developing a minimal path searching method for active shape model (ASM)-based segmentation for detection of lung boundaries on digital radiographs. With the conventional ASM method, the position and shape parameters of the model points are iteratively refined and the target points are updated by the least Mahalanobis distance criterion. We propose an improved searching strategy that extends the searching points in a fan-shape region instead of along the normal direction. A minimal path (MP) deformable model is applied to drive the searching procedure. A statistical shape prior model is incorporated into the segmentation. In order to keep the smoothness of the shape, a smooth constraint is employed to the deformable model. To quantitatively assess the ASM-MP segmentation, we compare the automatic segmentation with manual segmentation for 72 lung digitized radiographs. The distance error between the ASM-MP and manual segmentation is 1.75 ± 0.33 pixels, while the error is 1.99 ± 0.45 pixels for the ASM. Our results demonstrate that our ASM-MP method can accurately segment the lung on digital radiographs.
A minimal path searching approach for active shape model (ASM)-based segmentation of the lung
NASA Astrophysics Data System (ADS)
Guo, Shengwen; Fei, Baowei
2009-02-01
We are developing a minimal path searching method for active shape model (ASM)-based segmentation for detection of lung boundaries on digital radiographs. With the conventional ASM method, the position and shape parameters of the model points are iteratively refined and the target points are updated by the least Mahalanobis distance criterion. We propose an improved searching strategy that extends the searching points in a fan-shape region instead of along the normal direction. A minimal path (MP) deformable model is applied to drive the searching procedure. A statistical shape prior model is incorporated into the segmentation. In order to keep the smoothness of the shape, a smooth constraint is employed to the deformable model. To quantitatively assess the ASM-MP segmentation, we compare the automatic segmentation with manual segmentation for 72 lung digitized radiographs. The distance error between the ASM-MP and manual segmentation is 1.75 +/- 0.33 pixels, while the error is 1.99 +/- 0.45 pixels for the ASM. Our results demonstrate that our ASM-MP method can accurately segment the lung on digital radiographs.
A Minimal Path Searching Approach for Active Shape Model (ASM)-based Segmentation of the Lung
Guo, Shengwen; Fei, Baowei
2013-01-01
We are developing a minimal path searching method for active shape model (ASM)-based segmentation for detection of lung boundaries on digital radiographs. With the conventional ASM method, the position and shape parameters of the model points are iteratively refined and the target points are updated by the least Mahalanobis distance criterion. We propose an improved searching strategy that extends the searching points in a fan-shape region instead of along the normal direction. A minimal path (MP) deformable model is applied to drive the searching procedure. A statistical shape prior model is incorporated into the segmentation. In order to keep the smoothness of the shape, a smooth constraint is employed to the deformable model. To quantitatively assess the ASM-MP segmentation, we compare the automatic segmentation with manual segmentation for 72 lung digitized radiographs. The distance error between the ASM-MP and manual segmentation is 1.75 ± 0.33 pixels, while the error is 1.99 ± 0.45 pixels for the ASM. Our results demonstrate that our ASM-MP method can accurately segment the lung on digital radiographs. PMID:24386531
Coniferous forest classification and inventory using Landsat and digital terrain data
NASA Technical Reports Server (NTRS)
Franklin, J.; Logan, T. L.; Woodcock, C. E.; Strahler, A. H.
1986-01-01
Machine-processing techniques were used in a Forest Classification and Inventory System (FOCIS) procedure to extract and process tonal, textural, and terrain information from registered Landsat multispectral and digital terrain data. Using FOCIS as a basis for stratified sampling, the softwood timber volumes of the Klamath National Forest and Eldorado National Forest were estimated within standard errors of 4.8 and 4.0 percent, respectively. The accuracy of these large-area inventories is comparable to the accuracy yielded by use of conventional timber inventory methods, but, because of automation, the FOCIS inventories are more rapid (9-12 months compared to 2-3 years for conventional manual photointerpretation, map compilation and drafting, field sampling, and data processing) and are less costly.
Park, Sang Eun; Lee, Chun Taek
2007-10-01
This study was aimed to compare robotic-assisted implantation of a total knee arthroplasty with conventional manual implantation. We controlled, randomized, and reviewed 72 patients for total knee arthroplasty assigned to undergo either conventional manual implantation (excluding navigation-assisted implantation cases) of a Zimmer LPS prosthesis (Zimmer, Warsaw, Ind) (30 patients: group 1) or robotic-assisted implantation of such a prosthesis (32 patients: group 2). The femoral flexion angle (gamma angle) and tibial angle (delta angle) in the lateral x-ray of group 1 were 4.19 +/- 3.28 degrees and 89.7 +/- 1.7 degrees, and those of group 2 were 0.17 +/- 0.65 degrees and 85.5 +/- 0.92 degrees. The major complications were from improper small skin incision during a constraint attempt of minimally invasive surgery and during bulk fixation frame pins insertion. Robotic-assisted technology had definite advantages in terms of preoperative planning, accuracy of the intraoperative procedure, and postoperative follow-up, especially in the femoral flexion angle (gamma angle) and tibial flexion angle (delta angle) in the lateral x-ray, and in the femoral flexion angle (alpha angle) in the anteroposterior x-ray. But a disadvantage was the high complication rate in early stage.
Electronic compensation technique to deliver a total body dose
NASA Astrophysics Data System (ADS)
Lakeman, Tara E.
Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient's immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has been conventionally used to compensate for the varying thickness throughout the body in large-field TBI. The goal of this study is to pursue utilizing the modern electronic compensation technique to more accurately and efficiently deliver dose to patients in need of TBI. Method: Treatment plans utilizing the electronic compensation to deliver a total body dose were created retrospectively for patients for whom CT data had been previously acquired. Each treatment plan includes two pair of parallel opposed fields. One pair of large fields is used to encompass the majority of the patient's anatomy. The other pair are very small open fields focused only on the thin bottom portion of the patient's anatomy, which requires much less radiation than the rest of the body to reach 100% of the prescribed dose. A desirable fluence pattern was manually painted within each of the larger fields for each patient to provide a more uniform distribution. Results: Dose-volume histograms (DVH) were calculated for evaluating the electronic compensation technique. In the electronically compensated plans, the maximum body doses calculated from the DVH were reduced from the conventionally-compensated plans by an average of 15%, indicating a more uniform dose. The mean body doses calculated from the electronically compensated DVH remained comparable to that of the conventionally-compensated plans, indicating an accurate delivery of the prescription dose using electronic compensation. All calculated monitor units were within clinically acceptable limits. Conclusion: Electronic compensation technique for TBI will not increase the beam on time beyond clinically acceptable limits while it can substantially reduce the compensator setup time and the potential risk of errors in manually placing lead compensators.
Advantages and challenges in automated apatite fission track counting
NASA Astrophysics Data System (ADS)
Enkelmann, E.; Ehlers, T. A.
2012-04-01
Fission track thermochronometer data are often a core element of modern tectonic and denudation studies. Soon after the development of the fission track methods interest emerged for the developed an automated counting procedure to replace the time consuming labor of counting fission tracks under the microscope. Automated track counting became feasible in recent years with increasing improvements in computer software and hardware. One such example used in this study is the commercial automated fission track counting procedure from Autoscan Systems Pty that has been highlighted through several venues. We conducted experiments that are designed to reliably and consistently test the ability of this fully automated counting system to recognize fission tracks in apatite and a muscovite external detector. Fission tracks were analyzed in samples with a step-wise increase in sample complexity. The first set of experiments used a large (mm-size) slice of Durango apatite cut parallel to the prism plane. Second, samples with 80-200 μm large apatite grains of Fish Canyon Tuff were analyzed. This second sample set is characterized by complexities often found in apatites in different rock types. In addition to the automated counting procedure, the same samples were also analyzed using conventional counting procedures. We found for all samples that the fully automated fission track counting procedure using the Autoscan System yields a larger scatter in the fission track densities measured compared to conventional (manual) track counting. This scatter typically resulted from the false identification of tracks due surface and mineralogical defects, regardless of the image filtering procedure used. Large differences between track densities analyzed with the automated counting persisted between different grains analyzed in one sample as well as between different samples. As a result of these differences a manual correction of the fully automated fission track counts is necessary for each individual surface area and grain counted. This manual correction procedure significantly increases (up to four times) the time required to analyze a sample with the automated counting procedure compared to the conventional approach.
Lee, M-Y; Chang, C-C; Ku, Y C
2008-01-01
Fixed dental restoration by conventional methods greatly relies on the skill and experience of the dental technician. The quality and accuracy of the final product depends mostly on the technician's subjective judgment. In addition, the traditional manual operation involves many complex procedures, and is a time-consuming and labour-intensive job. Most importantly, no quantitative design and manufacturing information is preserved for future retrieval. In this paper, a new device for scanning the dental profile and reconstructing 3D digital information of a dental model based on a layer-based imaging technique, called abrasive computer tomography (ACT) was designed in-house and proposed for the design of custom dental restoration. The fixed partial dental restoration was then produced by rapid prototyping (RP) and computer numerical control (CNC) machining methods based on the ACT scanned digital information. A force feedback sculptor (FreeForm system, Sensible Technologies, Inc., Cambridge MA, USA), which comprises 3D Touch technology, was applied to modify the morphology and design of the fixed dental restoration. In addition, a comparison of conventional manual operation and digital manufacture using both RP and CNC machining technologies for fixed dental restoration production is presented. Finally, a digital custom fixed restoration manufacturing protocol integrating proposed layer-based dental profile scanning, computer-aided design, 3D force feedback feature modification and advanced fixed restoration manufacturing techniques is illustrated. The proposed method provides solid evidence that computer-aided design and manufacturing technologies may become a new avenue for custom-made fixed restoration design, analysis, and production in the 21st century.
Ricard, Philippe; Latcu, Decebal Gabriel; Yaïci, Khelil; Zarqane, Naima; Saoudi, Nadir
2010-01-01
The occurrence of accelerated junctional rhythm (JR) during radiofrequency ablation of the slow pathway in patients with atrioventricular nodal reentrant tachycardia (AVNRT) is frequent. The aim of the present study was to compare the occurrence of JR during magnetic remote catheter ablation to the conventional manual ablation. Twenty six patients (males: seven; age: 51 + or - 15 years) underwent slow pathway ablation with magnetic navigation (MN) system (Niobe, Stereotaxis Inc., St. Louis, MO, USA) and were compared to a control group of 11 patients (males: three; age: 53 + or - 16 years) treated with conventional manual ablation. A 4-mm nonirrigated tip catheter was used in both groups with a maximum of 30 W and 60 degrees C. Acute success was obtained in all patients. In the MN group, three patients out of 24 had no junctional beat (JB) at all and seven patients had 10 or less JB. In contrast, in the conventional group no patient had less than 10 JB. The mean number of JB in the MN group was 66 + or - 94.9 (0-410) and 200 + or - 243.1 (43-914) in the control group (P = 0.019). In the MN group one patient had a first-degree atrioventricular block. No other complication occurred. Magnetic remote catheter ablation of AVNRT is effective and is associated with less JB than the manual conventional technique. Therefore, JB may not be considered as a mandatory indicator for successful AVNRT ablation with MN system.
Video redaction: a survey and comparison of enabling technologies
NASA Astrophysics Data System (ADS)
Sah, Shagan; Shringi, Ameya; Ptucha, Raymond; Burry, Aaron; Loce, Robert
2017-09-01
With the prevalence of video recordings from smart phones, dash cams, body cams, and conventional surveillance cameras, privacy protection has become a major concern, especially in light of legislation such as the Freedom of Information Act. Video redaction is used to obfuscate sensitive and personally identifiable information. Today's typical workflow involves simple detection, tracking, and manual intervention. Automated methods rely on accurate detection mechanisms being paired with robust tracking methods across the video sequence to ensure the redaction of all sensitive information while minimizing spurious obfuscations. Recent studies have explored the use of convolution neural networks and recurrent neural networks for object detection and tracking. The present paper reviews the redaction problem and compares a few state-of-the-art detection, tracking, and obfuscation methods as they relate to redaction. The comparison introduces an evaluation metric that is specific to video redaction performance. The metric can be evaluated in a manner that allows balancing the penalty for false negatives and false positives according to the needs of particular application, thereby assisting in the selection of component methods and their associated hyperparameters such that the redacted video has fewer frames that require manual review.
Teaching Consumer Education and Financial Planning: A Manual for School and Classroom Use.
ERIC Educational Resources Information Center
Council for Family Financial Education, Silver Spring, MD.
This manual, designed for both the teacher and curriculum planner, is organized around six major themes: planning, buying, borrowing, protecting, investing, and sharing. These major areas are used in place of more conventional topical categories because the emphasis here is upon each individual's behavior. A chart is provided that shows the…
SU-G-IeP2-06: Evaluation of Registration Accuracy for Cone-Beam CT Reconstruction Techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, J; Wang, P; Zhang, H
2016-06-15
Purpose: Cone-beam (CB) computed tomography (CT) is used for image guidance during radiotherapy treatment delivery. Conventional Feldkamp and compressed sensing (CS) based CBCT recon-struction techniques are compared for image registration. This study is to evaluate the image registration accuracy of conventional and CS CBCT for head-and-neck (HN) patients. Methods: Ten HN patients with oropharyngeal tumors were retrospectively selected. Each HN patient had one planning CT (CTP) and three CBCTs were acquired during an adaptive radiotherapy proto-col. Each CBCT was reconstructed by both the conventional (CBCTCON) and compressed sens-ing (CBCTCS) methods. Two oncologists manually labeled 23 landmarks of normal tissue andmore » implanted gold markers on both the CTP and CBCTCON. Subsequently, landmarks on CTp were propagated to CBCTs, using a b-spline-based deformable image registration (DIR) and rigid registration (RR). The errors of these registration methods between two CBCT methods were calcu-lated. Results: For DIR, the mean distance between the propagated and the labeled landmarks was 2.8 mm ± 0.52 for CBCTCS, and 3.5 mm ± 0.75 for CBCTCON. For RR, the mean distance between the propagated and the labeled landmarks was 6.8 mm ± 0.92 for CBCTCS, and 8.7 mm ± 0.95 CBCTCON. Conclusion: This study has demonstrated that CS CBCT is more accurate than conventional CBCT in image registration by both rigid and non-rigid methods. It is potentially suggested that CS CBCT is an improved image modality for image guided adaptive applications.« less
Ughi, Giovanni J; Adriaenssens, Tom; Desmet, Walter; D’hooge, Jan
2012-01-01
Intravascular optical coherence tomography (IV-OCT) is an imaging modality that can be used for the assessment of intracoronary stents. Recent publications pointed to the fact that 3D visualizations have potential advantages compared to conventional 2D representations. However, 3D imaging still requires a time consuming manual procedure not suitable for on-line application during coronary interventions. We propose an algorithm for a rapid and fully automatic 3D visualization of IV-OCT pullbacks. IV-OCT images are first processed for the segmentation of the different structures. This also allows for automatic pullback calibration. Then, according to the segmentation results, different structures are depicted with different colors to visualize the vessel wall, the stent and the guide-wire in details. Final 3D rendering results are obtained through the use of a commercial 3D DICOM viewer. Manual analysis was used as ground-truth for the validation of the segmentation algorithms. A correlation value of 0.99 and good limits of agreement (Bland Altman statistics) were found over 250 images randomly extracted from 25 in vivo pullbacks. Moreover, 3D rendering was compared to angiography, pictures of deployed stents made available by the manufacturers and to conventional 2D imaging corroborating visualization results. Computational time for the visualization of an entire data sets resulted to be ~74 sec. The proposed method allows for the on-line use of 3D IV-OCT during percutaneous coronary interventions, potentially allowing treatments optimization. PMID:23243578
Feasibility of a Semi-computerized Line Bisection Test for Unilateral Visual Neglect Assessment.
Jee, H; Kim, J; Kim, C; Kim, T; Park, J
2015-01-01
Commonly used paper-and-pencil based test modalities for assessing the degree of unilateral visual neglect (ULN) in patients with hemispheric cerebral lesions consume human resources with a significant inter and intra-rater variability. To explore the feasibility of a semi-computerized electronic-pen based ULN assessment system (e-system) to improve assessment quality without altering the conventional user interface. Thirty cognitively healthy participants (HG) and 11 participants diagnosed with right-hemispheric lesion and unilateral visual neglect (NG) were recruited to evaluate the e-system. Line bisection tests (LBT) were repeatedly conducted twice for the inter-rater and intra-rater (reliability) comparisons. The LBT results were assessed by the e-system and the golden standard methods (manual rater assessment). The percent deviation (%), assessment duration (sec), and number of neglected line (each) were evaluated. The inter-rater comparisons of the assessed deviation (%) variable showed excellent interrater reliabilities (CCCs) ranging from .84 (.59 to .95 (p < .001)) to .99 (.90 to .99 (p < .001)) for HG and NG. The Bland Altman mean difference (B-A) plots with bias (95% LOA (limits of agreement)) showed similar agreements between the e-system and the raters ranging from -.04 % (-2.10 to 1.97) to 1.30 % (-2.23 to 4.84) for HG and NG. The effect sizes (ES), which show similarities between the assessment methods, yielded smaller ranges from .01 to .30 for HG and NG. The reliability (test-retest) comparisons showed similar assessment results between the e-system, rater 1, and rater 2. The manual rater assessment time ranging from 5.85 to 6.00 minutes and inter- and intraassessment variations were virtually eliminated with the e-system. The semi-computerized system with the conventional paper-and pencil user-interface showed valid and reliable assessment results. It may be a feasible replacement for the manual rater assessment modality even in a clinical setting.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Worm, Esben S., E-mail: esbeworm@rm.dk; Department of Medical Physics, Aarhus University Hospital, Aarhus; Hoyer, Morten
2012-05-01
Purpose: To develop and evaluate accurate and objective on-line patient setup based on a novel semiautomatic technique in which three-dimensional marker trajectories were estimated from two-dimensional cone-beam computed tomography (CBCT) projections. Methods and Materials: Seven treatment courses of stereotactic body radiotherapy for liver tumors were delivered in 21 fractions in total to 6 patients by a linear accelerator. Each patient had two to three gold markers implanted close to the tumors. Before treatment, a CBCT scan with approximately 675 two-dimensional projections was acquired during a full gantry rotation. The marker positions were segmented in each projection. From this, the three-dimensionalmore » marker trajectories were estimated using a probability based method. The required couch shifts for patient setup were calculated from the mean marker positions along the trajectories. A motion phantom moving with known tumor trajectories was used to examine the accuracy of the method. Trajectory-based setup was retrospectively used off-line for the first five treatment courses (15 fractions) and on-line for the last two treatment courses (6 fractions). Automatic marker segmentation was compared with manual segmentation. The trajectory-based setup was compared with setup based on conventional CBCT guidance on the markers (first 15 fractions). Results: Phantom measurements showed that trajectory-based estimation of the mean marker position was accurate within 0.3 mm. The on-line trajectory-based patient setup was performed within approximately 5 minutes. The automatic marker segmentation agreed with manual segmentation within 0.36 {+-} 0.50 pixels (mean {+-} SD; pixel size, 0.26 mm in isocenter). The accuracy of conventional volumetric CBCT guidance was compromised by motion smearing ({<=}21 mm) that induced an absolute three-dimensional setup error of 1.6 {+-} 0.9 mm (maximum, 3.2) relative to trajectory-based setup. Conclusions: The first on-line clinical use of trajectory estimation from CBCT projections for precise setup in stereotactic body radiotherapy was demonstrated. Uncertainty in the conventional CBCT-based setup procedure was eliminated with the new method.« less
Comparing errors in ED computer-assisted vs conventional pediatric drug dosing and administration.
Yamamoto, Loren; Kanemori, Joan
2010-06-01
Compared to fixed-dose single-vial drug administration in adults, pediatric drug dosing and administration requires a series of calculations, all of which are potentially error prone. The purpose of this study is to compare error rates and task completion times for common pediatric medication scenarios using computer program assistance vs conventional methods. Two versions of a 4-part paper-based test were developed. Each part consisted of a set of medication administration and/or dosing tasks. Emergency department and pediatric intensive care unit nurse volunteers completed these tasks using both methods (sequence assigned to start with a conventional or a computer-assisted approach). Completion times, errors, and the reason for the error were recorded. Thirty-eight nurses completed the study. Summing the completion of all 4 parts, the mean conventional total time was 1243 seconds vs the mean computer program total time of 879 seconds (P < .001). The conventional manual method had a mean of 1.8 errors vs the computer program with a mean of 0.7 errors (P < .001). Of the 97 total errors, 36 were due to misreading the drug concentration on the label, 34 were due to calculation errors, and 8 were due to misplaced decimals. Of the 36 label interpretation errors, 18 (50%) occurred with digoxin or insulin. Computerized assistance reduced errors and the time required for drug administration calculations. A pattern of errors emerged, noting that reading/interpreting certain drug labels were more error prone. Optimizing the layout of drug labels could reduce the error rate for error-prone labels. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Robotic single port cholecystectomy: current data and future perspectives.
Angelou, Anastasios; Skarmoutsos, Athanasios; Margonis, Georgios A; Moris, Demetrios; Tsigris, Christos; Pikoulis, Emmanouil
2017-04-01
Minimally invasive techniques are used more and more frequently. Since conventional laparoscopic approach has been the gold standard, surgeons in their effort to further reduce the invasiveness of conventional laparoscopic cholecystectomy have adopted Single Incision approach. The widespread adoption of robotics has led to the inevitable hybridization of robotic technology with laparoendoscopic single-site surgery (LESS). As a result, employment of the da Vinci surgical system may allow greater surgical maneuverability, improving ergonomics. A review of the English literature was conducted to evaluate all robotic single port cholecystectomy performed till today. Demographic data, operative parameters, postoperative outcomes and materials used for the operation were collected and assessed. A total of 12 studies, including 501 patients were analyzed. Demographics and clinical characteristics of the patients was heterogeneous, but in most studies a mean BMI <30 was recorded. Intraoperative metrics like operative time, estimated blood loss and conversion rate were comparable with those in multiport conventional laparoscopy. Robotic single port cholecystectomy is a safe and feasible alternative to conventional multiport laparoscopic or manual robotic approach. However, current data do not suggest a superiority of robotic SILC over other established methods.
Yoon, Jisun; Chun, Min Ho; Lee, Sook Joung; Kim, Bo Ryun
2015-06-01
The aim of this study was to evaluate the benefit of virtual reality-based rehabilitation on upper-extremity function in patients with brain tumor. Patients with upper-extremity dysfunction were divided into age-matched and tumor type-matched two groups. The intervention group performed the virtual reality program 30 mins per session for 9 sessions and conventional occupational therapy 30 mins per session for 6 sessions for 3 wks, whereas the control group received conventional occupational therapy alone 30 mins per session for 15 sessions for 3 wks. The Box and Block test, the Manual Function test, and the Fugl-Meyer scale were used to evaluate upper-extremity function. The Korean version of the Modified Barthel Index was used to assess activities of daily living. Forty patients completed the study (20 for each group). Each group exhibited significant posttreatment improvements in the Box and Block test, Manual Function test, Fugl-Meyer scale, and Korean version of the Modified Barthel Index scores. The Box and Block test, the Fugl-Meyer scale, and the Manual Function test showed greater improvements in shoulder/elbow/forearm function in the intervention group and hand function in the control group. Virtual reality-based rehabilitation combined with conventional occupational therapy may be more effective than conventional occupational therapy, especially for proximal upper-extremity function in patients with brain tumor. Further studies considering hand function, such as use of virtual reality programs that targeting hand use, are required.
Feng, Jingwen; Lin, Jie; Zhang, Pengquan; Yang, Songnan; Sa, Yu; Feng, Yuanming
2017-08-29
High-content screening is commonly used in studies of the DNA damage response. The double-strand break (DSB) is one of the most harmful types of DNA damage lesions. The conventional method used to quantify DSBs is γH2AX foci counting, which requires manual adjustment and preset parameters and is usually regarded as imprecise, time-consuming, poorly reproducible, and inaccurate. Therefore, a robust automatic alternative method is highly desired. In this manuscript, we present a new method for quantifying DSBs which involves automatic image cropping, automatic foci-segmentation and fluorescent intensity measurement. Furthermore, an additional function was added for standardizing the measurement of DSB response inhibition based on co-localization analysis. We tested the method with a well-known inhibitor of DSB response. The new method requires only one preset parameter, which effectively minimizes operator-dependent variations. Compared with conventional methods, the new method detected a higher percentage difference of foci formation between different cells, which can improve measurement accuracy. The effects of the inhibitor on DSB response were successfully quantified with the new method (p = 0.000). The advantages of this method in terms of reliability, automation and simplicity show its potential in quantitative fluorescence imaging studies and high-content screening for compounds and factors involved in DSB response.
Cao, Yi; Wang, Chao-Qun; Xu, Feng; Jia, Xiu-Hong; Liu, Guang-Xue; Yang, Sheng-Chao; Long, Guang-Qiang; Chen, Zhong-Jian; Wei, Fu-Zhou; Yang, Shao-Zhou; Fukuda, Kozo; Wang, Xuan; Cai, Shao-Qing
2016-10-01
Panax notoginseng is a commonly used traditional Chinese medicine with blood activating effect while has continuous cropping obstacle problem in planting process. In present study, a semimicroextraction method with water-saturated n-butanol on 0.1 g notoginseng sample was established with good repeatability (RSD<2.5%) and 9.6%-20.6% higher extraction efficiency of seven saponins than the conventional method. A total of 16 characteristic peaks were identified by LC-MS-IT-TOF, including eight 20(S)-protopanaxatriol (PPT) type saponins and eight 20(S)-protopanaxadiol (PPD) type saponins. The established method was utilized to evaluate the quality of notoginseng samples cultivated by manual intervened methods to overcome continuous cropping obstacles.As a result, HPLC fingerprint similarity, content of Fa and ratio of notoginsenoside K and notoginsenoside Fa (N-K/Fa) were found out to be as valuatable markers of the quality of samples in continuous cropping obstacle research, of which N-K/Fa could also be applied to the analysis of notoginseng samples with different growth years.Notoginseng samples with continuous cropping obstacle had HPLC fingerprint similarity lower than 0.87, in consistent with normal sample, and had significant lower content of notoginsenoside Fa and significant higher N-K/Fa (2.35-4.74) than normal group (0.45-1.33). All samples in the first group with manual intervention showed high similarity with normal group (>0.87), similar content of common peaks and N-K/Fa (0.42-2.06). The content of notoginsenoside K in the second group with manual intervention was higher than normal group. All samples except two displayed similarity higher than 0.87 and possessed content of 16 saponins close to normal group. The result showed that notoginseng samples with continuous cropping obstacle had lower quality than normal sample. And manual intervened methods could improve their quality in different levels.The method established in this study was simple, fast and accurate, and the markers may provide new guides for quality control in continuous cropping obstacle research of notoginseng. Copyright© by the Chinese Pharmaceutical Association.
Direct volume estimation without segmentation
NASA Astrophysics Data System (ADS)
Zhen, X.; Wang, Z.; Islam, A.; Bhaduri, M.; Chan, I.; Li, S.
2015-03-01
Volume estimation plays an important role in clinical diagnosis. For example, cardiac ventricular volumes including left ventricle (LV) and right ventricle (RV) are important clinical indicators of cardiac functions. Accurate and automatic estimation of the ventricular volumes is essential to the assessment of cardiac functions and diagnosis of heart diseases. Conventional methods are dependent on an intermediate segmentation step which is obtained either manually or automatically. However, manual segmentation is extremely time-consuming, subjective and highly non-reproducible; automatic segmentation is still challenging, computationally expensive, and completely unsolved for the RV. Towards accurate and efficient direct volume estimation, our group has been researching on learning based methods without segmentation by leveraging state-of-the-art machine learning techniques. Our direct estimation methods remove the accessional step of segmentation and can naturally deal with various volume estimation tasks. Moreover, they are extremely flexible to be used for volume estimation of either joint bi-ventricles (LV and RV) or individual LV/RV. We comparatively study the performance of direct methods on cardiac ventricular volume estimation by comparing with segmentation based methods. Experimental results show that direct estimation methods provide more accurate estimation of cardiac ventricular volumes than segmentation based methods. This indicates that direct estimation methods not only provide a convenient and mature clinical tool for cardiac volume estimation but also enables diagnosis of cardiac diseases to be conducted in a more efficient and reliable way.
Microscopic image analysis for reticulocyte based on watershed algorithm
NASA Astrophysics Data System (ADS)
Wang, J. Q.; Liu, G. F.; Liu, J. G.; Wang, G.
2007-12-01
We present a watershed-based algorithm in the analysis of light microscopic image for reticulocyte (RET), which will be used in an automated recognition system for RET in peripheral blood. The original images, obtained by micrography, are segmented by modified watershed algorithm and are recognized in term of gray entropy and area of connective area. In the process of watershed algorithm, judgment conditions are controlled according to character of the image, besides, the segmentation is performed by morphological subtraction. The algorithm was simulated with MATLAB software. It is similar for automated and manual scoring and there is good correlation(r=0.956) between the methods, which is resulted from 50 pieces of RET images. The result indicates that the algorithm for peripheral blood RETs is comparable to conventional manual scoring, and it is superior in objectivity. This algorithm avoids time-consuming calculation such as ultra-erosion and region-growth, which will speed up the computation consequentially.
Near-station terrain corrections for gravity data by a surface-integral technique
Gettings, M.E.
1982-01-01
A new method of computing gravity terrain corrections by use of a digitizer and digital computer can result in substantial savings in the time and manual labor required to perform such corrections by conventional manual ring-chart techniques. The method is typically applied to estimate terrain effects for topography near the station, for example within 3 km of the station, although it has been used successfully to a radius of 15 km to estimate corrections in areas where topographic mapping is poor. Points (about 20) that define topographic maxima, minima, and changes in the slope gradient are picked on the topographic map, within the desired radius of correction about the station. Particular attention must be paid to the area immediately surrounding the station to ensure a good topographic representation. The horizontal and vertical coordinates of these points are entered into the computer, usually by means of a digitizer. The computer then fits a multiquadric surface to the input points to form an analytic representation of the surface. By means of the divergence theorem, the gravity effect of an interior closed solid can be expressed as a surface integral, and the terrain correction is calculated by numerical evaluation of the integral over the surfaces of a cylinder, The vertical sides of which are at the correction radius about the station, the flat bottom surface at the topographic minimum, and the upper surface given by the multiquadric equation. The method has been tested with favorable results against models for which an exact result is available and against manually computed field-station locations in areas of rugged topography. By increasing the number of points defining the topographic surface, any desired degree of accuracy can be obtained. The method is more objective than manual ring-chart techniques because no average compartment elevations need be estimated ?
High quality tissue miniarray technique using a conventional TV/radio telescopic antenna.
Elkablawy, Mohamed A; Albasri, Abdulkader M
2015-01-01
The tissue microarray (TMA) is widely accepted as a fast and cost-effective research tool for in situ tissue analysis in modern pathology. However, the current automated and manual TMA techniques have some drawbacks restricting their productivity. Our study aimed to introduce an improved manual tissue miniarray (TmA) technique that is simple and readily applicable to a broad range of tissue samples. In this study, a conventional TV/radio telescopic antenna was used to punch tissue cores manually from donor paraffin embedded tissue blocks which were pre-incubated at 40oC. The cores were manually transferred, organized and attached to a standard block mould, and filled with liquid paraffin to construct TmA blocks without any use of recipient paraffin blocks. By using a conventional TV/radio antenna, it was possible to construct TmA paraffin blocks with variable formats of array size and number (2-mm x 42, 2.5-mm x 30, 3-mm x 24, 4-mm x 20 and 5-mm x 12 cores). Up to 2-mm x 84 cores could be mounted and stained on a standard microscopic slide by cutting two sections from two different blocks and mounting them beside each other. The technique was simple and caused minimal damage to the donor blocks. H and E and immunostained slides showed well-defined tissue morphology and array configuration. This technique is easy to reproduce, quick, inexpensive and creates uniform blocks with abundant tissues without specialized equipment. It was found to improve the stability of the cores within the paraffin block and facilitated no losses during cutting and immunostaining.
Fujimoto, S; Takahashi, M; Endoh, F; Takai, M; Kobayashi, K; Kiuchi, S; Konno, C; Obata, G; Okui, K
1991-09-01
From January 1983 to December 1989, we performed esophagojejunostomy on 379 patients who underwent total gastrectomy for gastric cancer. A mechanical EEA stapler or conventional manual suturing was used. The clinical outcomes of 199 patients in whom stapling was used (stapler group) and 180 patients in whom manual suturing was done (manual group) were compared. Two of the 199 patients in the stapler group and 3 of the 180 patients in the manual group died of causes directly related to the anastomosis. In the stapler group, 16 stapled anastomoses were formed supradiaphragmatically, and manual suturing was done for 6 patients. The highly placed anastomosis was formed without left thoracotomy or with median sternotomy in 8 of the 16 patients in whom the stapling device was used and in 1 of the 6 patients in whom manual suturing was used. The incidence of anastomotic leakage and stenosis did not differ between the groups. Thus, the mechanical stapler facilitated the construction of a rapid, reliable esophagojejunostomic anastomosis.
Trakoolwilaiwan, Thanawin; Behboodi, Bahareh; Lee, Jaeseok; Kim, Kyungsoo; Choi, Ji-Woong
2018-01-01
The aim of this work is to develop an effective brain-computer interface (BCI) method based on functional near-infrared spectroscopy (fNIRS). In order to improve the performance of the BCI system in terms of accuracy, the ability to discriminate features from input signals and proper classification are desired. Previous studies have mainly extracted features from the signal manually, but proper features need to be selected carefully. To avoid performance degradation caused by manual feature selection, we applied convolutional neural networks (CNNs) as the automatic feature extractor and classifier for fNIRS-based BCI. In this study, the hemodynamic responses evoked by performing rest, right-, and left-hand motor execution tasks were measured on eight healthy subjects to compare performances. Our CNN-based method provided improvements in classification accuracy over conventional methods employing the most commonly used features of mean, peak, slope, variance, kurtosis, and skewness, classified by support vector machine (SVM) and artificial neural network (ANN). Specifically, up to 6.49% and 3.33% improvement in classification accuracy was achieved by CNN compared with SVM and ANN, respectively.
Clinical utility of an automated instrument for gram staining single slides.
Baron, Ellen Jo; Mix, Samantha; Moradi, Wais
2010-06-01
Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis.
3-D rigid body tracking using vision and depth sensors.
Gedik, O Serdar; Alatan, A Aydn
2013-10-01
In robotics and augmented reality applications, model-based 3-D tracking of rigid objects is generally required. With the help of accurate pose estimates, it is required to increase reliability and decrease jitter in total. Among many solutions of pose estimation in the literature, pure vision-based 3-D trackers require either manual initializations or offline training stages. On the other hand, trackers relying on pure depth sensors are not suitable for AR applications. An automated 3-D tracking algorithm, which is based on fusion of vision and depth sensors via extended Kalman filter, is proposed in this paper. A novel measurement-tracking scheme, which is based on estimation of optical flow using intensity and shape index map data of 3-D point cloud, increases 2-D, as well as 3-D, tracking performance significantly. The proposed method requires neither manual initialization of pose nor offline training, while enabling highly accurate 3-D tracking. The accuracy of the proposed method is tested against a number of conventional techniques, and a superior performance is clearly observed in terms of both objectively via error metrics and subjectively for the rendered scenes.
Mori, Masanobu; Nakano, Koji; Sasaki, Masaya; Shinozaki, Haruka; Suzuki, Shiho; Okawara, Chitose; Miró, Manuel; Itabashi, Hideyuki
2016-02-01
A dynamic flow-through microcolumn extraction system based on extractant re-circulation is herein proposed as a novel analytical approach for simplification of bioaccessibility tests of trace elements in sediments. On-line metal leaching is undertaken in the format of all injection (AI) analysis, which is a sequel of flow injection analysis, but involving extraction under steady-state conditions. The minimum circulation times and flow rates required to determine the maximum bioaccessible pools of target metals (viz., Cu, Zn, Cd, and Pb) from lake and river sediment samples were estimated using Tessier's sequential extraction scheme and an acid single extraction test. The on-line AIA method was successfully validated by mass balance studies of CRM and real sediment samples. Tessier's test in on-line AI format demonstrated to be carried out by one third of extraction time (6h against more than 17 h by the conventional method), with better analytical precision (<9.2% against >15% by the conventional method) and significant decrease in blank readouts as compared with the manual batch counterpart. Copyright © 2015 Elsevier B.V. All rights reserved.
Kim, Won-Seok; Zeng, Pengcheng; Shi, Jian Qing; Lee, Youngjo; Paik, Nam-Jong
2017-01-01
Motion analysis of the hyoid bone via videofluoroscopic study has been used in clinical research, but the classical manual tracking method is generally labor intensive and time consuming. Although some automatic tracking methods have been developed, masked points could not be tracked and smoothing and segmentation, which are necessary for functional motion analysis prior to registration, were not provided by the previous software. We developed software to track the hyoid bone motion semi-automatically. It works even in the situation where the hyoid bone is masked by the mandible and has been validated in dysphagia patients with stroke. In addition, we added the function of semi-automatic smoothing and segmentation. A total of 30 patients' data were used to develop the software, and data collected from 17 patients were used for validation, of which the trajectories of 8 patients were partly masked. Pearson correlation coefficients between the manual and automatic tracking are high and statistically significant (0.942 to 0.991, P-value<0.0001). Relative errors between automatic tracking and manual tracking in terms of the x-axis, y-axis and 2D range of hyoid bone excursion range from 3.3% to 9.2%. We also developed an automatic method to segment each hyoid bone trajectory into four phases (elevation phase, anterior movement phase, descending phase and returning phase). The semi-automatic hyoid bone tracking from VFSS data by our software is valid compared to the conventional manual tracking method. In addition, the ability of automatic indication to switch the automatic mode to manual mode in extreme cases and calibration without attaching the radiopaque object is convenient and useful for users. Semi-automatic smoothing and segmentation provide further information for functional motion analysis which is beneficial to further statistical analysis such as functional classification and prognostication for dysphagia. Therefore, this software could provide the researchers in the field of dysphagia with a convenient, useful, and all-in-one platform for analyzing the hyoid bone motion. Further development of our method to track the other swallowing related structures or objects such as epiglottis and bolus and to carry out the 2D curve registration may be needed for a more comprehensive functional data analysis for dysphagia with big data.
Shin, Byung-Cheul; Kim, Me-Riong; Cho, Jae-Heung; Jung, Jae-Young; Kim, Koh-Woon; Lee, Jun-Hwan; Nam, Kibong; Lee, Min Ho; Hwang, Eui-Hyoung; Heo, Kwang-Ho; Kim, Namkwen; Ha, In-Hyuk
2017-01-17
While Chuna manual therapy is a Korean manual therapy widely used primarily for low back pain (LBP)-related disorders in Korea, well-designed studies on the comparative effectiveness of Chuna manual therapy are scarce. This study is the protocol for a three-armed, multicenter, pragmatic randomized controlled pilot trial. Sixty severe nonacute LBP patients (pain duration of at least 3 weeks, Numeric Rating Scale (NRS) ≥5) will be recruited at four Korean medicine hospitals. Participants will be randomly allocated to the Chuna group (n = 20), usual care group (n = 20), or Chuna plus usual care group (n = 20) for 6 weeks of treatment. Usual care will consist of orally administered conventional medicine, physical therapy, and back pain care education. The trial will be conducted with outcome assessor and statistician blinding. The primary endpoint will be NRS of LBP at week 7 post randomization. Secondary outcomes include NRS of leg pain, the Oswestry Disability Index (ODI), the Patient Global Impression of Change (PGIC), the Credibility and Expectancy Questionnaire, lumbar range of motion (ROM), the EuroQol-5 Dimension (EQ-5D) health survey, the Health Utility Index III (HUI-III), and economic evaluation and safety data. Post-treatment follow-ups will be conducted at 1, 4, and 10 weeks after conclusion of treatment. This study will assess the comparative effectiveness of Chuna manual therapy compared to conventional usual care. Costs and effectiveness (utility) data will be analyzed for exploratory cost-effectiveness analysis. If this pilot study does not reach a definite conclusion due to its small sample size, these results will be used as preliminary results to calculate sample size for future large-scale clinical trials and contribute in the assessment of feasibility of a full-scale multicenter trial. Clinical Research Information Service (CRIS), KCT0001850 . Registered on 17 March 2016.
Metal matrix composite analyzer (METCAN) user's manual, version 4.0
NASA Technical Reports Server (NTRS)
Lee, H.-J.; Gotsis, P. K.; Murthy, P. L. N.; Hopkins, D. A.
1992-01-01
The Metal Matrix Composite Analyzer (METCAN) is a computer code developed at Lewis Research Center to simulate the high temperature nonlinear behavior of metal matrix composites. An updated version of the METCAN User's Manual is presented. The manual provides the user with a step by step outline of the procedure necessary to run METCAN. The preparation of the input file is demonstrated, and the output files are explained. The sample problems are presented to highlight various features of METCAN. An overview of the geometric conventions, micromechanical unit cell, and the nonlinear constitutive relationships is also provided.
2009-06-12
Phasing Model ......................................................................................................9 Figure 2. The Continuum of...the communist periphery. In a high-intensity conflict, doctrine at the time called for conventional forces to fight the traditional, linear fight...operations and proximity of cross component forces in a non- linear battlespace – Rigid business rules, translator applications, or manual workarounds to
Comparison of Nitinol Stapes Pistons with Conventional Stapes Pistons: A Cadaver Study
2011-01-01
Comparison of Nitinol Stapes Pistons with Conventional Stapes Pistons: A Cadaver Study Samuel A. Spear1 and James V. Crawford2 1 48th Medical Group, ENT...cited. Objective. To visually compare the Nitinol “smart” stapes prosthesis to conventional manual crimping stapes pistons in temporal bone cadaver...answer questions about each stapes piston. The answers to the survey were then recorded for analysis. Results. 8 of 9 Nitinol pistons were described as
Jayaratne, Yasas Shri Nalaka; Uribe, Flavio; Janakiraman, Nandakumar
2017-01-01
The objective of this systematic review was to compare the antero-posterior, vertical and angular changes of maxillary incisors with conventional anchorage control techniques and mini-implant based space closure methods. The electronic databases Pubmed, Scopus, ISI Web of knowledge, Cochrane Library and Open Grey were searched for potentially eligible studies using a set of predetermined keywords. Full texts meeting the inclusion criteria as well as their references were manually searched. The primary outcome data (linear, angular, and vertical maxillary incisor changes) and secondary outcome data (overbite changes, soft tissue changes, biomechanical factors, root resorption and treatment duration) were extracted from the selected articles and entered into spreadsheets based on the type of anchorage used. The methodological quality of each study was assessed. Six studies met the inclusion criteria. The amount of incisor retraction was greater with buccally placed mini-implants than conventional anchorage techniques. The incisor retraction with indirect anchorage from palatal mini-implants was less when compared with buccally placed mini-implants. Incisor intrusion occurred with buccal mini-implants, whereas extrusion was seen with conventional anchorage. Limited data on the biomechanical variables or adverse effects such as root resorption were reported in these studies. More RCT's that take in to account relevant biomechanical variables and employ three-dimensional quantification of tooth movements are required to provide information on incisor changes during space closure.
Sample, Paul J.; Gaston, Kirk W.; Alfonzo, Juan D.; Limbach, Patrick A.
2015-01-01
Ribosomal ribonucleic acid (RNA), transfer RNA and other biological or synthetic RNA polymers can contain nucleotides that have been modified by the addition of chemical groups. Traditional Sanger sequencing methods cannot establish the chemical nature and sequence of these modified-nucleotide containing oligomers. Mass spectrometry (MS) has become the conventional approach for determining the nucleotide composition, modification status and sequence of modified RNAs. Modified RNAs are analyzed by MS using collision-induced dissociation tandem mass spectrometry (CID MS/MS), which produces a complex dataset of oligomeric fragments that must be interpreted to identify and place modified nucleosides within the RNA sequence. Here we report the development of RoboOligo, an interactive software program for the robust analysis of data generated by CID MS/MS of RNA oligomers. There are three main functions of RoboOligo: (i) automated de novo sequencing via the local search paradigm. (ii) Manual sequencing with real-time spectrum labeling and cumulative intensity scoring. (iii) A hybrid approach, coined ‘variable sequencing’, which combines the user intuition of manual sequencing with the high-throughput sampling of automated de novo sequencing. PMID:25820423
Comparison of manual steering and steering via joystick of a flexible rhino endoscope.
Eckl, R; Gumprecht, J J; Strauss, G; Hofer, M; Dietz, A; Lueth, T C
2010-01-01
Flexible endoscopes are used in ENT surgery for examination tasks in cases wherever rigid endoscopes are unsuitable to reach certain positions in the nasal cavity. Until today they are steered by hand and no robotized system has been put into clinical practice. One qualification a robot manipulator system has to fulfill to be accepted is not to create new disadvantages compared to the conventional method in surgery. An important factor is the time needed to steer the new system compared to the time needed to steer the conventional system. In this article a robot manipulator system and an experiment are presented to compare the particular times test persons need to perform a certain task. This approach offers the possibility to benchmark the developed robot manipulator system and future systems for flexible rhino endoscopes.
High‐resolution trench photomosaics from image‐based modeling: Workflow and error analysis
Reitman, Nadine G.; Bennett, Scott E. K.; Gold, Ryan D.; Briggs, Richard; Duross, Christopher
2015-01-01
Photomosaics are commonly used to construct maps of paleoseismic trench exposures, but the conventional process of manually using image‐editing software is time consuming and produces undesirable artifacts and distortions. Herein, we document and evaluate the application of image‐based modeling (IBM) for creating photomosaics and 3D models of paleoseismic trench exposures, illustrated with a case‐study trench across the Wasatch fault in Alpine, Utah. Our results include a structure‐from‐motion workflow for the semiautomated creation of seamless, high‐resolution photomosaics designed for rapid implementation in a field setting. Compared with conventional manual methods, the IBM photomosaic method provides a more accurate, continuous, and detailed record of paleoseismic trench exposures in approximately half the processing time and 15%–20% of the user input time. Our error analysis quantifies the effect of the number and spatial distribution of control points on model accuracy. For this case study, an ∼87 m2 exposure of a benched trench photographed at viewing distances of 1.5–7 m yields a model with <2 cm root mean square error (rmse) with as few as six control points. Rmse decreases as more control points are implemented, but the gains in accuracy are minimal beyond 12 control points. Spreading control points throughout the target area helps to minimize error. We propose that 3D digital models and corresponding photomosaics should be standard practice in paleoseismic exposure archiving. The error analysis serves as a guide for future investigations that seek balance between speed and accuracy during photomosaic and 3D model construction.
Tsubono, Y; Fukao, A; Hisamichi, S
1994-06-01
A self-administered questionnaire using the mark-sheet method (MSM), in which responses of subjects are computer processed directly through an optical scanning device, has recently been utilized in epidemiologic surveys. Compared to the data coding process for a conventional questionnaire, in which a keypuncher enters the responses manually into a computer (manual method; MM), optical scanning requires less time and cost. Accuracy of the MSM for use in the general population in Japan, however, remains uncertain. Therefore the response rates, frequencies of missing values, validity and reproducibility of the answers in self-administered questionnaires were compared between the MSM and MM. Subjects were 463 residents aged 40-69 years living in 6 local districts of a rural town in northeastern Japan. They were randomly allocated, by district basis, to the MSM group (n = 242) or the MM group (n = 221). The questionnaire was delivered and collected at the subject's home by volunteers. Two weeks after collecting the original questionnaire, the same type of questionnaire was again distributed to half of the responders randomly chosen to investigate reproducibility. The overall response rate did not differ in MSM and MM (96.7% vs 98.2%, p = 0.312). Among questions with a multiple-choice type of answer, proportions of missing values were not different for most of the items, but it was lower in MSM for all of the 33 food frequency items. Reproducibilities of food frequency items measured by Spearman's rank correlation did not differ substantially in two groups.(ABSTRACT TRUNCATED AT 250 WORDS)
Hiraki, Takao; Kamegawa, Tetsushi; Matsuno, Takayuki; Sakurai, Jun; Kirita, Yasuzo; Matsuura, Ryutaro; Yamaguchi, Takuya; Sasaki, Takanori; Mitsuhashi, Toshiharu; Komaki, Toshiyuki; Masaoka, Yoshihisa; Matsui, Yusuke; Fujiwara, Hiroyasu; Iguchi, Toshihiro; Gobara, Hideo; Kanazawa, Susumu
2017-11-01
Purpose To evaluate the accuracy of the remote-controlled robotic computed tomography (CT)-guided needle insertion in phantom and animal experiments. Materials and Methods In a phantom experiment, 18 robotic and manual insertions each were performed with 19-gauge needles by using CT fluoroscopic guidance for the evaluation of the equivalence of accuracy of insertion between the two groups with a 1.0-mm margin. Needle insertion time, CT fluoroscopy time, and radiation exposure were compared by using the Student t test. The animal experiments were approved by the institutional animal care and use committee. In the animal experiment, five robotic insertions each were attempted toward targets in the liver, kidneys, lungs, and hip muscle of three swine by using 19-gauge or 17-gauge needles and by using conventional CT guidance. The feasibility, safety, and accuracy of robotic insertion were evaluated. Results The mean accuracies of robotic and manual insertion in phantoms were 1.6 and 1.4 mm, respectively. The 95% confidence interval of the mean difference was -0.3 to 0.6 mm. There were no significant differences in needle insertion time, CT fluoroscopy time, or radiation exposure to the phantom between the two methods. Effective dose to the physician during robotic insertion was always 0 μSv, while that during manual insertion was 5.7 μSv on average (P < .001). Robotic insertion was feasible in the animals, with an overall mean accuracy of 3.2 mm and three minor procedure-related complications. Conclusion Robotic insertion exhibited equivalent accuracy as manual insertion in phantoms, without radiation exposure to the physician. It was also found to be accurate in an in vivo procedure in animals. © RSNA, 2017 Online supplemental material is available for this article.
Vairo, Giampietro L; Miller, Sayers John; McBrier, Nicole M; Buckley, William E
2009-01-01
Manual therapists question integrating manual lymphatic drainage techniques (MLDTs) into conventional treatments for athletic injuries due to the scarcity of literature concerning musculoskeletal applications and established orthopaedic clinical practice guidelines. The purpose of this systematic review is to provide manual therapy clinicians with pertinent information regarding progression of MLDTs as well as to critique the evidence for efficacy of this method in sports medicine. We surveyed English-language publications from 1998 to 2008 by searching PubMed, PEDro, CINAHL, the Cochrane Library, and SPORTDiscus databases using the terms lymphatic system, lymph drainage, lymphatic therapy, manual lymph drainage, and lymphatic pump techniques. We selected articles investigating the effects of MLDTs on orthopaedic and athletic injury outcomes. Nine articles met inclusion criteria, of which 3 were randomized controlled trials (RCTs). We evaluated the 3 RCTs using a validity score (PEDro scale). Due to differences in experimental design, data could not be collapsed for meta-analysis. Animal model experiments reinforce theoretical principles for application of MLDTs. When combined with concomitant musculoskeletal therapy, pilot and case studies demonstrate MLDT effectiveness. The best evidence suggests that efficacy of MLDT in sports medicine and rehabilitation is specific to resolution of enzyme serum levels associated with acute skeletal muscle cell damage as well as reduction of edema following acute ankle joint sprain and radial wrist fracture. Currently, there is limited high-ranking evidence available. Well-designed RCTs assessing outcome variables following implementation of MLDTs in treating athletic injuries may provide conclusive evidence for establishing applicable clinical practice guidelines in sports medicine and rehabilitation.
Shen, Elizabeth P; Chen, Wei-Li; Hu, Fung-Rong
2010-03-01
To compare the efficacy and safety of manual limbal markings and wavefront-guided treatment with iris-registration software in laser in situ keratomileusis (LASIK) for myopic astigmatism. National Taiwan University Hospital, Taipei, Taiwan. Eyes with myopic astigmatism had LASIK with a Technolas 217z laser. Eyes in the limbal-marking group had conventional LASIK (PlanoScan or Zyoptix tissue-saving algorithm) with manual cyclotorsional-error adjustments according to 2 limbal marks. Eyes in the iris-registration group had wavefront-guided ablation (Zyoptix) in which cyclotorsional errors were automatically detected and adjusted. Refraction, corneal topography, and visual acuity data were compared between groups. Vector analysis was by the Alpins method. The mean preoperative spherical equivalent (SE) was -6.64 diopters (D) +/- 1.99 (SD) in the limbal-marking group and -6.72 +/- 1.86 D in the iris-registration group (P = .92). At 6 months, the mean SE was -0.42 +/- 0.63 D and -0.47 +/- 0.62 D, respectively (P = .08). There was no statistically significant difference between groups in the astigmatism correction, success, or flattening index values using 6-month postoperative refractive data. The angle of error was within +/-10 degrees in 73% of eyes in the limbal-marking group and 75% of eyes in the iris-registration group. Manual limbal markings and iris-registration software were equally effective and safe in LASIK for myopic astigmatism, showing that checking cyclotorsion by manual limbal markings is a safe alternative when automated systems are not available. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Miyazaki, Shinsuke; Shah, Ashok J; Xhaët, Olivier; Derval, Nicolas; Matsuo, Seiichiro; Wright, Matthew; Nault, Isabelle; Forclaz, Andrei; Jadidi, Amir S; Knecht, Sébastien; Rivard, Lena; Liu, Xingpeng; Linton, Nick; Sacher, Frédéric; Hocini, Mélèze; Jaïs, Pierre; Haïssaguerre, Michel
2010-12-01
The remote magnetic navigation system (MNS) has been used with a nonirrigated magnetic catheter for atrial fibrillation (AF) ablation. The objective of this study was to evaluate the feasibility and efficiency of the newly available irrigated tip magnetic catheter for index pulmonary vein isolation (PVI) in patients with paroxysmal AF (PAF). Between January 2008 and June 2009, 30 consecutive patients with drug-resistant PAF underwent circular mapping catheter-guided PVI with MNS (MNS group). The outcomes were compared retrospectively with those of a conventional hand-controlled ablation technique during the same period in 44 consecutive patients (manual group). All 4 pulmonary veins were successfully isolated in both groups except in 4 patients in the MNS group. Radiofrequency and procedure duration were higher in the MNS group (60 ± 27 versus 43 ± 16 minutes; P = 0.0019) than in the manual group (246 ± 50 versus 153 ± 51 minutes; P < 0.0001). In the patients who underwent only PVI, total fluoroscopic time also was longer in the MNS group than in the manual group (58 ± 24 versus 40 ± 14 minutes; P = 0.0002). At 12-month follow-up after a single procedure, 69.0% of the patients in MNS group and 61.8% of patients in manual group were free of atrial tachyarrhythmia without antiarrhythmic drugs. There was no significant difference in the atrial tachyarrhythmia-free survival between the 2 groups (P = 0.961). Cardiac tamponade occurred in 1 patient in the manual group. In patients with PAF, MNS-guided PVI with the newly available irrigated tip magnetic catheter backed up with manual ablation whenever required is feasible. However, it requires longer ablation, fluoroscopy, and procedural times than the conventional approach in the early experience stage.
Tuning time-frequency methods for the detection of metered HF speech
NASA Astrophysics Data System (ADS)
Nelson, Douglas J.; Smith, Lawrence H.
2002-12-01
Speech is metered if the stresses occur at a nearly regular rate. Metered speech is common in poetry, and it can occur naturally in speech, if the speaker is spelling a word or reciting words or numbers from a list. In radio communications, the CQ request, call sign and other codes are frequently metered. In tactical communications and air traffic control, location, heading and identification codes may be metered. Moreover metering may be expected to survive even in HF communications, which are corrupted by noise, interference and mistuning. For this environment, speech recognition and conventional machine-based methods are not effective. We describe Time-Frequency methods which have been adapted successfully to the problem of mitigation of HF signal conditions and detection of metered speech. These methods are based on modeled time and frequency correlation properties of nearly harmonic functions. We derive these properties and demonstrate a performance gain over conventional correlation and spectral methods. Finally, in addressing the problem of HF single sideband (SSB) communications, the problems of carrier mistuning, interfering signals, such as manual Morse, and fast automatic gain control (AGC) must be addressed. We demonstrate simple methods which may be used to blindly mitigate mistuning and narrowband interference, and effectively invert the fast automatic gain function.
[Effects of rice-duck mutualistic organic farming on rice quality in the Yellow River Delta, China.
Wang, Jian Lin; Li, Jie; Cao, Yuan Yuan
2016-07-01
Three cultivation models including rice-duck mutualistic, manual weeding and conventional rice farming were designed in the Yellow River Delta area to study the effects on rice milling quality, appearance quality, cooking and eating quality, and sanitation quality. The results showed that compared to conventional rice farming, the rice-duckmutualistic treatment increased grain width and brown rice rate, milled rice rate, head rice rate and reduced the chalkiness. This was mainly due to the increase of panicle numbers and grain mass and the decrease of the inferior grains. Due to the application of organic manure, the gel consistency increased, amylose and protein contents decreased, and the rice taste improved under rice-duck mutualistic and manual weeding cultivation treatments. As no chemical fertilizers and pesticides were applied under rice-duck mutualistic and manual weeding treatments, pesticide residues were greatly reduced or even not detected. Rice duck farming could improve the quality of rice and protect the environment, which would be a good ecological technology for high quality rice production.
The computational structural mechanics testbed generic structural-element processor manual
NASA Technical Reports Server (NTRS)
Stanley, Gary M.; Nour-Omid, Shahram
1990-01-01
The usage and development of structural finite element processors based on the CSM Testbed's Generic Element Processor (GEP) template is documented. By convention, such processors have names of the form ESi, where i is an integer. This manual is therefore intended for both Testbed users who wish to invoke ES processors during the course of a structural analysis, and Testbed developers who wish to construct new element processors (or modify existing ones).
[Functional electric stimulation (FES) in cerebral palsy].
Miyazaki, M H; Lourenção, M I; Ribeiro Sobrinho, J B; Battistella, L R
1992-01-01
Our study concerns a patient with cerebral palsy, submitted to conventional occupational therapy and functional electrical stimulation. The results as to manual ability, spasticity, sensibility and synkinesis were satisfactory.
Yukimasa, Nobuyasu; Miura, Keisuke; Miyagawa, Yukiko; Fukuchi, Kunihiko
2015-01-01
Automated nontreponemal and treponemal test reagents based on the latex agglutination method (immunoticles auto3 RPR: ITA3RPR and immunoticles auto3 TP: ITA3TP) have been developed to improve the issues of conventional manual methods such as their subjectivity, a massive amount of assays, and so on. We evaluated these reagents in regards to their performance, reactivity to antibody isotype, and their clinical significance. ITA3RPR and ITA3TP were measured using a clinical chemistry analyzer. Reactivity to antibody isotype was examined by gel filtration analysis. ITA3RPR and ITA3TP showed reactivity to both IgM- and IgG-class antibodies and detected early infections. ITA3RPR was verified to show a higher reactivity to IgM-class antibodies than the conventional methods. ITA3RPR correlated with VDRL in the high titer range, and measurement values decreased with treatment. ITA3RPR showed a negative result earlier after treatment than conventional methods. ITA3TP showed high specificity and did not give any false-negative reaction. Significant differences in the measurement values of ITA3RPR between the infective and previous group were verified. The double test of ITA3RPR and ITA3TP enables efficient and objective judgment for syphilis diagnosis and treatments, achieving clinical availability. Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Grant, Richard John; Roberts, Karen; Pointon, Carly; Hodgson, Clare; Womersley, Lynsey; Jones, Darren Craig; Tang, Eric
2009-06-01
Compound handling is a fundamental and critical step in compound screening throughout the drug discovery process. Although most compound-handling processes within compound management facilities use 100% DMSO solvent, conventional methods of manual or robotic liquid-handling systems in screening workflows often perform dilutions in aqueous solutions to maintain solvent tolerance of the biological assay. However, the use of aqueous media in these applications can lead to suboptimal data quality due to compound carryover or precipitation during the dilution steps. In cell-based assays, this effect is worsened by the unpredictable physical characteristics of compounds and the low DMSO tolerance within the assay. In some cases, the conventional approaches using manual or automated liquid handling resulted in variable IC(50) dose responses. This study examines the cause of this variability and evaluates the accuracy of screening data in these case studies. A number of liquid-handling options have been explored to address the issues and establish a generic compound-handling workflow to support cell-based screening across our screening functions. The authors discuss the validation of the Labcyte Echo reformatter as an effective noncontact solution for generic compound-handling applications against diverse compound classes using triple-quad liquid chromatography/mass spectrometry. The successful validation and implementation challenges of this technology for direct dosing onto cells in cell-based screening is discussed.
Clinical Utility of an Automated Instrument for Gram Staining Single Slides ▿
Baron, Ellen Jo; Mix, Samantha; Moradi, Wais
2010-01-01
Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis. PMID:20410348
Radar fall detection using principal component analysis
NASA Astrophysics Data System (ADS)
Jokanovic, Branka; Amin, Moeness; Ahmad, Fauzia; Boashash, Boualem
2016-05-01
Falls are a major cause of fatal and nonfatal injuries in people aged 65 years and older. Radar has the potential to become one of the leading technologies for fall detection, thereby enabling the elderly to live independently. Existing techniques for fall detection using radar are based on manual feature extraction and require significant parameter tuning in order to provide successful detections. In this paper, we employ principal component analysis for fall detection, wherein eigen images of observed motions are employed for classification. Using real data, we demonstrate that the PCA based technique provides performance improvement over the conventional feature extraction methods.
Procedure for the systematic orientation of digitised cranial models. Design and validation.
Bailo, M; Baena, S; Marín, J J; Arredondo, J M; Auría, J M; Sánchez, B; Tardío, E; Falcón, L
2015-12-01
Comparison of bony pieces requires that they are oriented systematically to ensure that homologous regions are compared. Few orientation methods are highly accurate; this is particularly true for methods applied to three-dimensional models obtained by surface scanning, a technique whose special features make it a powerful tool in forensic contexts. The aim of this study was to develop and evaluate a systematic, assisted orientation method for aligning three-dimensional cranial models relative to the Frankfurt Plane, which would be produce accurate orientations independent of operator and anthropological expertise. The study sample comprised four crania of known age and sex. All the crania were scanned and reconstructed using an Eva Artec™ portable 3D surface scanner and subsequently, the position of certain characteristic landmarks were determined by three different operators using the Rhinoceros 3D surface modelling software. Intra-observer analysis showed a tendency for orientation to be more accurate when using the assisted method than when using conventional manual orientation. Inter-observer analysis showed that experienced evaluators achieve results at least as accurate if not more accurate using the assisted method than those obtained using manual orientation; while inexperienced evaluators achieved more accurate orientation using the assisted method. The method tested is a an innovative system capable of providing very precise, systematic and automatised spatial orientations of virtual cranial models relative to standardised anatomical planes independent of the operator and operator experience. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Knight, M T; Newman, M C; Benzinger, M J; Neufang, K L; Agin, J R; McAllister, J S; Ramos, M
1997-01-01
A collaborative study was performed involving 18 laboratories and 6 food types to compare 3M Petrifilm yeast and mold count plates with the method described in the U.S. Food and Drug Administration's Bacteriological Analytical Manual. Four species of mold and 2 species of yeast were used to inoculate the following foods: hot dogs, corn meal, ketchup, orange juice, yogurt, and cake mix. Each collaborator received 15 samples of each food type: 5 low-level inoculations, 5 high-level inoculations, and 5 uninoculated samples. There was no significant difference between the means of the 2 methods for any product or inoculation level. The Petrifilm yeast and mold count plate method for enumeration of yeasts and molds in foods has been adopted first action by AOAC INTERNATIONAL.
Deep Learning for Automated Extraction of Primary Sites From Cancer Pathology Reports.
Qiu, John X; Yoon, Hong-Jun; Fearn, Paul A; Tourassi, Georgia D
2018-01-01
Pathology reports are a primary source of information for cancer registries which process high volumes of free-text reports annually. Information extraction and coding is a manual, labor-intensive process. In this study, we investigated deep learning and a convolutional neural network (CNN), for extracting ICD-O-3 topographic codes from a corpus of breast and lung cancer pathology reports. We performed two experiments, using a CNN and a more conventional term frequency vector approach, to assess the effects of class prevalence and inter-class transfer learning. The experiments were based on a set of 942 pathology reports with human expert annotations as the gold standard. CNN performance was compared against a more conventional term frequency vector space approach. We observed that the deep learning models consistently outperformed the conventional approaches in the class prevalence experiment, resulting in micro- and macro-F score increases of up to 0.132 and 0.226, respectively, when class labels were well populated. Specifically, the best performing CNN achieved a micro-F score of 0.722 over 12 ICD-O-3 topography codes. Transfer learning provided a consistent but modest performance boost for the deep learning methods but trends were contingent on the CNN method and cancer site. These encouraging results demonstrate the potential of deep learning for automated abstraction of pathology reports.
Pieterman, Elise D; Budde, Ricardo P J; Robbers-Visser, Daniëlle; van Domburg, Ron T; Helbing, Willem A
2017-09-01
Follow-up of right ventricular performance is important for patients with congenital heart disease. Cardiac magnetic resonance imaging is optimal for this purpose. However, observer-dependency of manual analysis of right ventricular volumes limit its use. Knowledge-based reconstruction is a new semiautomatic analysis tool that uses a database including knowledge of right ventricular shape in various congenital heart diseases. We evaluated whether knowledge-based reconstruction is a good alternative for conventional analysis. To assess the inter- and intra-observer variability and agreement of knowledge-based versus conventional analysis of magnetic resonance right ventricular volumes, analysis was done by two observers in a mixed group of 22 patients with congenital heart disease affecting right ventricular loading conditions (dextro-transposition of the great arteries and right ventricle to pulmonary artery conduit) and a group of 17 healthy children. We used Bland-Altman analysis and coefficient of variation. Comparison between the conventional method and the knowledge-based method showed a systematically higher volume for the latter group. We found an overestimation for end-diastolic volume (bias -40 ± 24 mL, r = .956), end-systolic volume (bias -34 ± 24 mL, r = .943), stroke volume (bias -6 ± 17 mL, r = .735) and an underestimation of ejection fraction (bias 7 ± 7%, r = .671) by knowledge-based reconstruction. The intra-observer variability of knowledge-based reconstruction varied with a coefficient of variation of 9% for end-diastolic volume and 22% for stroke volume. The same trend was noted for inter-observer variability. A systematic difference (overestimation) was noted for right ventricular size as assessed with knowledge-based reconstruction compared with conventional methods for analysis. Observer variability for the new method was comparable to what has been reported for the right ventricle in children and congenital heart disease with conventional analysis. © 2017 Wiley Periodicals, Inc.
Stubbs, Samuel; Oura, Chris A L; Henstock, Mark; Bowden, Timothy R; King, Donald P; Tuppurainen, Eeva S M
2012-02-01
Capripoxviruses, which are endemic in much of Africa and Asia, are the aetiological agents of economically devastating poxviral diseases in cattle, sheep and goats. The aim of this study was to validate a high-throughput real-time PCR assay for routine diagnostic use in a capripoxvirus reference laboratory. The performance of two previously published real-time PCR methods were compared using commercially available reagents including the amplification kits recommended in the original publication. Furthermore, both manual and robotic extraction methods used to prepare template nucleic acid were evaluated using samples collected from experimentally infected animals. The optimised assay had an analytical sensitivity of at least 63 target DNA copies per reaction, displayed a greater diagnostic sensitivity compared to conventional gel-based PCR, detected capripoxviruses isolated from outbreaks around the world and did not amplify DNA from related viruses in the genera Orthopoxvirus or Parapoxvirus. The high-throughput robotic DNA extraction procedure did not adversely affect the sensitivity of the assay compared to manual preparation of PCR templates. This laboratory-based assay provides a rapid and robust method to detect capripoxviruses following suspicion of disease in endemic or disease-free countries. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.
Treatment manuals, training and successful provision of stop smoking behavioural support.
Brose, Leonie S; McEwen, Andy; Michie, Susan; West, Robert; Chew, Xie Yin; Lorencatto, Fabiana
2015-08-01
Translating evidence-based behaviour change interventions into practice is aided by use of treatment manuals specifying the recommended content and format of interventions, and evidence-based training. This study examined whether outcomes of stop smoking behavioural support differed with practitioner's use and evaluation of treatment manuals, or practitioner's training. English stop smoking practitioners were invited to complete an online survey including questions on: practitioners' training, availability, use and perceived utility of manuals, and annual biochemically-validated success rates of quit attempts supported (practitioner-reported). Mean success rates were compared between practitioners with/without access to manuals, those using/not using manuals, perceived utility ratings of manuals, and consecutive levels of training completed. Success rates were higher if practitioners had a manual (Mean (SD) = 54.0 (24.0) versus 48.0 (25.3), t(838) = 2.48, p = 0.013; n = 840), used a manual (F(2,8237) = 4.78, p = 0.009, n = 840), perceived manuals as more useful (F(3,834) = 2.90, p = 0.034, n = 840), and had completed training (F(3,709) = 4.81, p = 0.002, n = 713). Differences were diminished when adjusting for professional and demographic characteristics and no longer reached statistical significance using a conventional alpha for perceived utility of manuals and training status (both p = 0.1). Practitioners' performance in supporting smokers to quit varied with availability and use of treatment manuals. Evidence was weaker for perceived utility of manuals and practitioners' evidence-based training. Ensuring practitioners have access to treatment manuals within their service, promoting manual use, and training practitioners to competently apply manuals is likely to contribute to higher success rates in clinical practice. Copyright © 2015 Elsevier Ltd. All rights reserved.
Unicompartmental knee arthroplasty: is robotic technology more accurate than conventional technique?
Citak, Mustafa; Suero, Eduardo M; Citak, Musa; Dunbar, Nicholas J; Branch, Sharon H; Conditt, Michael A; Banks, Scott A; Pearle, Andrew D
2013-08-01
Robotic-assisted unicompartmental knee arthroplasty (UKA) with rigid bone fixation "can significantly improve implant placement and leg alignment. The aim of this cadaveric study was to determine whether the use of robotic systems with dynamic bone tracking would provide more accurate UKA implant positioning compared to the conventional manual technique. Three-dimensional CT-based preoperative plans were created to determine the desired position and orientation for the tibial and femoral components. For each pair of cadaver knees, UKA was performed using traditional instrumentation on the left side and using a haptic robotic system on the right side. Postoperative CT scans were obtained and 3D-to-3D iterative closest point registration was performed. Implant position and orientation were compared to the preoperative plan. Surgical RMS errors for femoral component placement were within 1.9 mm and 3.7° in all directions of the planned implant position for the robotic group, while RMS errors for the manual group were within 5.4mm and 10.2°. Average RMS errors for tibial component placement were within 1.4mm and 5.0° in all directions for the robotic group; while, for the manual group, RMS errors were within 5.7 mm and 19.2°. UKA was more precise using a semiactive robotic system with dynamic bone tracking technology compared to the manual technique. Copyright © 2012 Elsevier B.V. All rights reserved.
SPACE PROPULSION SYSTEM PHASED-MISSION PROBABILITY ANALYSIS USING CONVENTIONAL PRA METHODS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Curtis Smith; James Knudsen
As part of a series of papers on the topic of advance probabilistic methods, a benchmark phased-mission problem has been suggested. This problem consists of modeling a space mission using an ion propulsion system, where the mission consists of seven mission phases. The mission requires that the propulsion operate for several phases, where the configuration changes as a function of phase. The ion propulsion system itself consists of five thruster assemblies and a single propellant supply, where each thruster assembly has one propulsion power unit and two ion engines. In this paper, we evaluate the probability of mission failure usingmore » the conventional methodology of event tree/fault tree analysis. The event tree and fault trees are developed and analyzed using Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE). While the benchmark problem is nominally a "dynamic" problem, in our analysis the mission phases are modeled in a single event tree to show the progression from one phase to the next. The propulsion system is modeled in fault trees to account for the operation; or in this case, the failure of the system. Specifically, the propulsion system is decomposed into each of the five thruster assemblies and fed into the appropriate N-out-of-M gate to evaluate mission failure. A separate fault tree for the propulsion system is developed to account for the different success criteria of each mission phase. Common-cause failure modeling is treated using traditional (i.e., parametrically) methods. As part of this paper, we discuss the overall results in addition to the positive and negative aspects of modeling dynamic situations with non-dynamic modeling techniques. One insight from the use of this conventional method for analyzing the benchmark problem is that it requires significant manual manipulation to the fault trees and how they are linked into the event tree. The conventional method also requires editing the resultant cut sets to obtain the correct results. While conventional methods may be used to evaluate a dynamic system like that in the benchmark, the level of effort required may preclude its use on real-world problems.« less
NASA Technical Reports Server (NTRS)
Schweikhard, W. G.; Dennon, S. R.
1986-01-01
A review of the Melick method of inlet flow dynamic distortion prediction by statistical means is provided. These developments include the general Melick approach with full dynamic measurements, a limited dynamic measurement approach, and a turbulence modelling approach which requires no dynamic rms pressure fluctuation measurements. These modifications are evaluated by comparing predicted and measured peak instantaneous distortion levels from provisional inlet data sets. A nonlinear mean-line following vortex model is proposed and evaluated as a potential criterion for improving the peak instantaneous distortion map generated from the conventional linear vortex of the Melick method. The model is simplified to a series of linear vortex segments which lay along the mean line. Maps generated with this new approach are compared with conventionally generated maps, as well as measured peak instantaneous maps. Inlet data sets include subsonic, transonic, and supersonic inlets under various flight conditions.
NASA Astrophysics Data System (ADS)
Zagouras, Athanassios; Argiriou, Athanassios A.; Flocas, Helena A.; Economou, George; Fotopoulos, Spiros
2012-11-01
Classification of weather maps at various isobaric levels as a methodological tool is used in several problems related to meteorology, climatology, atmospheric pollution and to other fields for many years. Initially the classification was performed manually. The criteria used by the person performing the classification are features of isobars or isopleths of geopotential height, depending on the type of maps to be classified. Although manual classifications integrate the perceptual experience and other unquantifiable qualities of the meteorology specialists involved, these are typically subjective and time consuming. Furthermore, during the last years different approaches of automated methods for atmospheric circulation classification have been proposed, which present automated and so-called objective classifications. In this paper a new method of atmospheric circulation classification of isobaric maps is presented. The method is based on graph theory. It starts with an intelligent prototype selection using an over-partitioning mode of fuzzy c-means (FCM) algorithm, proceeds to a graph formulation for the entire dataset and produces the clusters based on the contemporary dominant sets clustering method. Graph theory is a novel mathematical approach, allowing a more efficient representation of spatially correlated data, compared to the classical Euclidian space representation approaches, used in conventional classification methods. The method has been applied to the classification of 850 hPa atmospheric circulation over the Eastern Mediterranean. The evaluation of the automated methods is performed by statistical indexes; results indicate that the classification is adequately comparable with other state-of-the-art automated map classification methods, for a variable number of clusters.
NASA Technical Reports Server (NTRS)
Nichols, J. D.; Gialdini, M.; Jaakkola, S.
1974-01-01
A quasi-operational study demonstrating that a timber inventory based on manual and automated analysis of ERTS-1, supporting aircraft data and ground data was made using multistage sampling techniques. The inventory proved to be a timely, cost effective alternative to conventional timber inventory techniques. The timber volume on the Quincy Ranger District of the Plumas National Forest was estimated to be 2.44 billion board feet with a sampling error of 8.2 percent. Costs per acre for the inventory procedure at 1.1 cent/acre compared favorably with the costs of a conventional inventory at 25 cents/acre. A point-by-point comparison of CALSCAN-classified ERTS data with human-interpreted low altitude photo plots indicated no significant differences in the overall classification accuracies.
Contour Tracking in Echocardiographic Sequences via Sparse Representation and Dictionary Learning
Huang, Xiaojie; Dione, Donald P.; Compas, Colin B.; Papademetris, Xenophon; Lin, Ben A.; Bregasi, Alda; Sinusas, Albert J.; Staib, Lawrence H.; Duncan, James S.
2013-01-01
This paper presents a dynamical appearance model based on sparse representation and dictionary learning for tracking both endocardial and epicardial contours of the left ventricle in echocardiographic sequences. Instead of learning offline spatiotemporal priors from databases, we exploit the inherent spatiotemporal coherence of individual data to constraint cardiac contour estimation. The contour tracker is initialized with a manual tracing of the first frame. It employs multiscale sparse representation of local image appearance and learns online multiscale appearance dictionaries in a boosting framework as the image sequence is segmented frame-by-frame sequentially. The weights of multiscale appearance dictionaries are optimized automatically. Our region-based level set segmentation integrates a spectrum of complementary multilevel information including intensity, multiscale local appearance, and dynamical shape prediction. The approach is validated on twenty-six 4D canine echocardiographic images acquired from both healthy and post-infarct canines. The segmentation results agree well with expert manual tracings. The ejection fraction estimates also show good agreement with manual results. Advantages of our approach are demonstrated by comparisons with a conventional pure intensity model, a registration-based contour tracker, and a state-of-the-art database-dependent offline dynamical shape model. We also demonstrate the feasibility of clinical application by applying the method to four 4D human data sets. PMID:24292554
Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit MS
2018-01-01
Purpose To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. Patients and methods This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Results Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p=0.005). Postoperative refractive cylinder was −0.89±0.35 D in group I and −0.64±0.36 D in group II (p=0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio (p<0.05) and modulation transfer function (MTF) (p<0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) (p<0.05). Conclusion Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment. PMID:29731603
3D Ultrasonic Non-destructive Evaluation of Spot Welds Using an Enhanced Total Focusing Method
NASA Astrophysics Data System (ADS)
Jasiuniene, Elena; Samaitis, Vykintas; Mazeika, Liudas; Sanderson, Ruth
2015-02-01
Spot welds are used to join sheets of metals in the automotive industry. When spot weld quality is evaluated using conventional ultrasonic manual pulse-echo method, the reliability of the inspection is affected by selection of the probe diameter and the positioning of the probe in the weld center. The application of a 2D matrix array is a potential solution to the aforementioned problems. The objective of this work was to develop a signal processing algorithm to reconstruct the 3D spot weld volume showing the size of the nugget and the defects in it. In order to achieve this, the conventional total focusing method was enhanced by taking into account the directivities of the single elements of the array and the divergence of the ultrasonic beam due to the propagation distance. Enhancements enabled a reduction in the background noise and uniform sensitivity at different depths to be obtained. The proposed algorithm was verified using a finite element model of ultrasonic wave propagation simulating three common spot weld conditions: a good weld, an undersized weld, and a weld containing a pore. The investigations have demonstrated that proposed method enables the determination of the size of the nugget and detection of discontinuities.
Farida, Abesi; Maryam, Ehsani; Ali, Mirzapour; Ehsan, Moudi; Sajad, Yousefi; Soraya, Khafri
2013-01-01
Obtaining a correct working length is necessary for successful root canal treatment. The aim of this study was to compare conventional and digital radiography in measuring root canal working length. In this in vitro study 20 mesio buccal canal from maxillary first molars with moderate and severe curvature and 20 canal form anterior teeth with mild curvature were chosen and their working length were measured with number 15 k file (Maillefer, DENTSPLY, Germany). Then for each canal five radiographies were taken, three conventional radiographies using three methods of processing: Manual, automatic, and monobath solution; in addition to two other digital radiographies using CCD and PSP receptors. Two independent observers measured working length in each technique. Finally, the mean of working length in each group was compared with real working length using a paired T-test. Also a one-way ANOVA test was used for comparing the two groups. The level of statistical significance was P < 0.05. The results have shown that there was a high interobserver agreement on the measurements of the working length in conventional and digital radiography (P ≤ 0.001). Also there was no significant difference between conventional and digital radiography in measuring working length (P > 0.05). Therefore it was concluded that the accuracy of digital radiography is comparable with conventional radiography in measuring working length, so considering the advantages of the digital radiography, it can be used for working length determination.
Longoni, Juliano N.; Lopes, Beatriz M.; Freires, Irlan A.; Dutra, Kamile L.; Franco, Ademir; Paranhos, Luiz R.
2017-01-01
Objective: The present study aimed to review the literature systematically and assess comparatively whether self-ligating metallic brackets accumulate less Streptococcus mutans biofilm than conventional metallic brackets. Material and methods: The systematic search was performed following PRISMA guidelines and registration in PROSPERO. Seven electronic databases (Google Scholar, LILACS, Open Grey, PubMed, SciELO, ScienceDirect, and Scopus) were consulted until April 2016, with no restriction of language and time of publication. Only randomized clinical studies verifying S. mutans colonization in metallic brackets (self-ligating and conventional) were included. All steps were performed independently by two operators. Results: The search resulted in 546 records obtained from the electronic databases. Additionally, 216 references obtained from the manual search of eligible articles were assessed. Finally, a total of 5 studies were included in the qualitative synthesis. In 1 study, the total bacterial count was not different among self-ligating and conventional brackets, whereas in 2 studies the amount was lower for self-ligating brackets. Regarding the specific count of S. mutans, 2 studies showed less accumulation in self-ligating than in conventional brackets. Conclusion: Based on the limited evidence, self-ligating metallic brackets accumulate less S. mutans than conventional ones. However, these findings must be interpreted in conjunction with particularities individual for each patient – such as hygiene and dietary habits, which are components of the multifactorial environment that enables S. Mutans to proliferate and keep retained in the oral cavity. PMID:29279684
Imai, Norio; Ito, Tomoyuki; Suda, Ken; Miyasaka, Dai; Endo, Naoto
2017-07-01
Venous thromboembolism is one of the general complications following total hip arthroplasty, wherein various preventive treatments have been recommended. Several studies reported that venous thromboembolism incidence after total hip arthroplasty was similar in patients who were administered prophylaxis with a conventional mechanical procedure alone, and those who were administered pharmacological anticoagulation therapy. Therefore, the optimum methods of prophylaxis are still controversial. The purpose of this study was to investigate whether manual calf massage and passive ankle motion could lower the risk for venous thromboembolism after total hip arthroplasty. We retrospectively reviewed the data of 126 consecutive patients undergoing elective primary unilateral total hip arthroplasty wherein manual calf massage and passive ankle motion were performed after the surgery at our hospitals between January and October 2014. The 138 patients of the control group underwent total hip arthroplasty using the same surgical approach and pre- and postoperative protocols without this mechanical prophylaxis between January and December 2013. This mechanical prophylaxis was performed simultaneously 30 times during approximately 10 s; these procedures were repeated thrice immediately after total hip arthroplasty. Duplex ultrasonography was performed to observe the veins of both legs in all the patients on postoperative day 7. The incidence of deep vein thrombosis was 6.52% and 0.79% in the control and manual calf massage and passive ankle motion groups, respectively. The odds ratio for the manual calf massage and passive ankle motion groups was 8.72. Performing this mechanical prophylaxis reduced the incidence of venous thromboembolism after total hip arthroplasty. This mechanical prophylaxis is not only simple and easy, but is also safe and inexpensive. We therefore recommend that manual calf massage and passive ankle motion be performed in patients who will undergo total hip arthroplasty, if deep vein thrombosis does not exist before the surgery. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Tichý, Ondřej; Šmídl, Václav; Hofman, Radek; Stohl, Andreas
2016-11-01
Estimation of pollutant releases into the atmosphere is an important problem in the environmental sciences. It is typically formalized as an inverse problem using a linear model that can explain observable quantities (e.g., concentrations or deposition values) as a product of the source-receptor sensitivity (SRS) matrix obtained from an atmospheric transport model multiplied by the unknown source-term vector. Since this problem is typically ill-posed, current state-of-the-art methods are based on regularization of the problem and solution of a formulated optimization problem. This procedure depends on manual settings of uncertainties that are often very poorly quantified, effectively making them tuning parameters. We formulate a probabilistic model, that has the same maximum likelihood solution as the conventional method using pre-specified uncertainties. Replacement of the maximum likelihood solution by full Bayesian estimation also allows estimation of all tuning parameters from the measurements. The estimation procedure is based on the variational Bayes approximation which is evaluated by an iterative algorithm. The resulting method is thus very similar to the conventional approach, but with the possibility to also estimate all tuning parameters from the observations. The proposed algorithm is tested and compared with the standard methods on data from the European Tracer Experiment (ETEX) where advantages of the new method are demonstrated. A MATLAB implementation of the proposed algorithm is available for download.
Communication Systems for Dual Mode Transportation
DOT National Transportation Integrated Search
1974-02-01
A program is underway to develop and demonstrate transportation systems based on vehicles which are capable of automatic operation on special guideways and manual operation on conventional roads. Adequate and reliable communications to and from vehic...
The integrated manual and automatic control of complex flight systems
NASA Technical Reports Server (NTRS)
Schmidt, D. K.
1984-01-01
A unified control synthesis methodology for complex and/or non-conventional flight vehicles are developed. Prediction techniques for the handling characteristics of such vehicles and pilot parameter identification from experimental data are addressed.
NASA Astrophysics Data System (ADS)
Romînu, Roxana Otilia; Sinescu, Cosmin; Romînu, Mihai; Negrutiu, Meda; Laissue, Philippe; Mihali, Sorin; Cuc, Lavinia; Hughes, Michael; Bradu, Adrian; Podoleanu, Adrian
2008-09-01
Bonding has become a routine procedure in several dental specialties - from prosthodontics to conservative dentistry and even orthodontics. In many of these fields it is important to be able to investigate the bonded interfaces to assess their quality. All currently employed investigative methods are invasive, meaning that samples are destroyed in the testing procedure and cannot be used again. We have investigated the interface between human enamel and bonded ceramic brackets non-invasively, introducing a combination of new investigative methods - optical coherence tomography (OCT) and confocal microscopy (CM). Brackets were conventionally bonded on conditioned buccal surfaces of teeth The bonding was assessed using these methods. Three dimensional reconstructions of the detected material defects were developed using manual and semi-automatic segmentation. The results clearly prove that OCT and CM are useful in orthodontic bonding investigations.
Optimal graph based segmentation using flow lines with application to airway wall segmentation.
Petersen, Jens; Nielsen, Mads; Lo, Pechin; Saghir, Zaigham; Dirksen, Asger; de Bruijne, Marleen
2011-01-01
This paper introduces a novel optimal graph construction method that is applicable to multi-dimensional, multi-surface segmentation problems. Such problems are often solved by refining an initial coarse surface within the space given by graph columns. Conventional columns are not well suited for surfaces with high curvature or complex shapes but the proposed columns, based on properly generated flow lines, which are non-intersecting, guarantee solutions that do not self-intersect and are better able to handle such surfaces. The method is applied to segment human airway walls in computed tomography images. Comparison with manual annotations on 649 cross-sectional images from 15 different subjects shows significantly smaller contour distances and larger area of overlap than are obtained with recently published graph based methods. Airway abnormality measurements obtained with the method on 480 scan pairs from a lung cancer screening trial are reproducible and correlate significantly with lung function.
A Ground Truthing Method for AVIRIS Overflights Using Canopy Absorption Spectra
NASA Technical Reports Server (NTRS)
Gamon, John A.; Serrano, Lydia; Roberts, Dar A.; Ustin, Susan L.
1996-01-01
Remote sensing for ecological field studies requires ground truthing for accurate interpretation of remote imagery. However, traditional vegetation sampling methods are time consuming and hard to relate to the scale of an AVIRIS scene. The large errors associated with manual field sampling, the contrasting formats of remote and ground data, and problems with coregistration of field sites with AVIRIS pixels can lead to difficulties in interpreting AVIRIS data. As part of a larger study of fire risk in the Santa Monica Mountains of southern California, we explored a ground-based optical method of sampling vegetation using spectrometers mounted both above and below vegetation canopies. The goal was to use optical methods to provide a rapid, consistent, and objective means of "ground truthing" that could be related both to AVIRIS imagery and to conventional ground sampling (e.g., plot harvests and pigment assays).
A Computer-Aided Distinction Method of Borderline Grades of Oral Cancer
NASA Astrophysics Data System (ADS)
Sami, Mustafa M.; Saito, Masahisa; Muramatsu, Shogo; Kikuchi, Hisakazu; Saku, Takashi
We have developed a new computer-aided diagnostic system for differentiating oral borderline malignancies in hematoxylin-eosin stained microscopic images. Epithelial dysplasia and carcinoma in-situ (CIS) of oral mucosa are two different borderline grades similar to each other, and it is difficult to distinguish between them. A new image processing and analysis method has been applied to a variety of histopathological features and shows the possibility for differentiating the oral cancer borderline grades automatically. The method is based on comparing the drop-shape similarity level in a particular manually selected pair of neighboring rete ridges. It was found that the considered similarity level in dysplasia was higher than those in epithelial CIS, of which pathological diagnoses were conventionally made by pathologists. The developed image processing method showed a good promise for the computer-aided pathological assessment of oral borderline malignancy differentiation in clinical practice.
Texture segmentation by genetic programming.
Song, Andy; Ciesielski, Vic
2008-01-01
This paper describes a texture segmentation method using genetic programming (GP), which is one of the most powerful evolutionary computation algorithms. By choosing an appropriate representation texture, classifiers can be evolved without computing texture features. Due to the absence of time-consuming feature extraction, the evolved classifiers enable the development of the proposed texture segmentation algorithm. This GP based method can achieve a segmentation speed that is significantly higher than that of conventional methods. This method does not require a human expert to manually construct models for texture feature extraction. In an analysis of the evolved classifiers, it can be seen that these GP classifiers are not arbitrary. Certain textural regularities are captured by these classifiers to discriminate different textures. GP has been shown in this study as a feasible and a powerful approach for texture classification and segmentation, which are generally considered as complex vision tasks.
Forghani-Arani, Farnoush; Behura, Jyoti; Haines, Seth S.; Batzle, Mike
2013-01-01
In studies on heavy oil, shale reservoirs, tight gas and enhanced geothermal systems, the use of surface passive seismic data to monitor induced microseismicity due to the fluid flow in the subsurface is becoming more common. However, in most studies passive seismic records contain days and months of data and manually analysing the data can be expensive and inaccurate. Moreover, in the presence of noise, detecting the arrival of weak microseismic events becomes challenging. Hence, the use of an automated, accurate and computationally fast technique for event detection in passive seismic data is essential. The conventional automatic event identification algorithm computes a running-window energy ratio of the short-term average to the long-term average of the passive seismic data for each trace. We show that for the common case of a low signal-to-noise ratio in surface passive records, the conventional method is not sufficiently effective at event identification. Here, we extend the conventional algorithm by introducing a technique that is based on the cross-correlation of the energy ratios computed by the conventional method. With our technique we can measure the similarities amongst the computed energy ratios at different traces. Our approach is successful at improving the detectability of events with a low signal-to-noise ratio that are not detectable with the conventional algorithm. Also, our algorithm has the advantage to identify if an event is common to all stations (a regional event) or to a limited number of stations (a local event). We provide examples of applying our technique to synthetic data and a field surface passive data set recorded at a geothermal site.
Real-time myocardium segmentation for the assessment of cardiac function variation
NASA Astrophysics Data System (ADS)
Zoehrer, Fabian; Huellebrand, Markus; Chitiboi, Teodora; Oechtering, Thekla; Sieren, Malte; Frahm, Jens; Hahn, Horst K.; Hennemuth, Anja
2017-03-01
Recent developments in MRI enable the acquisition of image sequences with high spatio-temporal resolution. Cardiac motion can be captured without gating and triggering. Image size and contrast relations differ from conventional cardiac MRI cine sequences requiring new adapted analysis methods. We suggest a novel segmentation approach utilizing contrast invariant polar scanning techniques. It has been tested with 20 datasets of arrhythmia patients. The results do not differ significantly more between automatic and manual segmentations than between observers. This indicates that the presented solution could enable clinical applications of real-time MRI for the examination of arrhythmic cardiac motion in the future.
Modern digital flight control system design for VTOL aircraft
NASA Technical Reports Server (NTRS)
Broussard, J. R.; Berry, P. W.; Stengel, R. F.
1979-01-01
Methods for and results from the design and evaluation of a digital flight control system (DFCS) for a CH-47B helicopter are presented. The DFCS employed proportional-integral control logic to provide rapid, precise response to automatic or manual guidance commands while following conventional or spiral-descent approach paths. It contained altitude- and velocity-command modes, and it adapted to varying flight conditions through gain scheduling. Extensive use was made of linear systems analysis techniques. The DFCS was designed, using linear-optimal estimation and control theory, and the effects of gain scheduling are assessed by examination of closed-loop eigenvalues and time responses.
Validity of a Manual Soft Tissue Profile Prediction Method Following Mandibular Setback Osteotomy
Kolokitha, Olga-Elpis
2007-01-01
Objectives The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. Methods To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Results Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Conclusions Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication. PMID:19212468
Holmström, Oscar; Linder, Nina; Lundin, Mikael; Moilanen, Hannu; Suutala, Antti; Turkki, Riku; Joensuu, Heikki; Isola, Jorma; Diwan, Vinod; Lundin, Johan
2015-01-01
Introduction A significant barrier to medical diagnostics in low-resource environments is the lack of medical care and equipment. Here we present a low-cost, cloud-connected digital microscope for applications at the point-of-care. We evaluate the performance of the device in the digital assessment of estrogen receptor-alpha (ER) expression in breast cancer samples. Studies suggest computer-assisted analysis of tumor samples digitized with whole slide-scanners may be comparable to manual scoring, here we study whether similar results can be obtained with the device presented. Materials and Methods A total of 170 samples of human breast carcinoma, immunostained for ER expression, were digitized with a high-end slide-scanner and the point-of-care microscope. Corresponding regions from the samples were extracted, and ER status was determined visually and digitally. Samples were classified as ER negative (<1% ER positivity) or positive, and further into weakly (1–10% positivity) and strongly positive. Interobserver agreement (Cohen’s kappa) was measured and correlation coefficients (Pearson’s product-momentum) were calculated for comparison of the methods. Results Correlation and interobserver agreement (r = 0.98, p < 0.001, kappa = 0.84, CI95% = 0.75–0.94) were strong in the results from both devices. Concordance of the point-of-care microscope and the manual scoring was good (r = 0.94, p < 0.001, kappa = 0.71, CI95% = 0.61–0.80), and comparable to the concordance between the slide scanner and manual scoring (r = 0.93, p < 0.001, kappa = 0.69, CI95% = 0.60–0.78). Fourteen (8%) discrepant cases between manual and device-based scoring were present with the slide scanner, and 16 (9%) with the point-of-care microscope, all representing samples of low ER expression. Conclusions Tumor ER status can be accurately quantified with a low-cost imaging device and digital image-analysis, with results comparable to conventional computer-assisted or manual scoring. This technology could potentially be expanded for other histopathological applications at the point-of-care. PMID:26659386
Tsuchida, Keiichi; García-García, Héctor M; van der Giessen, Willem J; McFadden, Eugène P; van der Ent, Martin; Sianos, Georgios; Meulenbrug, Hans; Ong, Andrew T L; Serruys, Patrick W
2006-03-01
The objective of this study was to investigate the efficacy of guidewire navigation across coronary artery stenoses using magnetic navigation system (MNS) versus conventional navigation. The MNS is a novel option to facilitate access to target lesions, particularly in tortuous vessels. In an experimental study using a challenging vessel phantom, magnetic-navigated guidewire passage has been reported to reduce fluoroscopy and procedure time significantly. Both magnetic and manual guidewire navigation were attempted in 21 consecutive diseased coronary arteries. The study endpoint was defined as an intraluminal wire position distal to the stenosis. Procedural success was defined as successful guidewire passage without procedural events. Procedure time, amount of contrast, fluoroscopy time, and radiation dose/area product (DAP) were evaluated. There were no procedural events related to either guidewire. Although the lesions attempted had relatively simple and straightforward characteristics, significantly shorter procedure and fluoroscopy time were observed for manual guidewire navigation compared to MNS (median, 40 vs. 120 sec, P=0.001; 38 vs. 105 sec, P=0.001, respectively). Contrast amount and DAP were higher in MNS than in conventional method (median, 13 vs. 9 ml, P=0.018; 215 vs. 73 Gym2, P=0.002, respectively). The magnetic wire did not cross in two vessels. Guidewire navigation using MNS presented a novel, safe, and feasible approach to address coronary artery lesions. Clinical studies are needed to evaluate the potential benefit of the MNS in more complex coronary lesions and tortuous anatomy. Copyright (c) 2006 Wiley-Liss, Inc.
Danker, Timm; Braun, Franziska; Silbernagl, Nikole; Guenther, Elke
2016-03-01
Manual patch clamp, the gold standard of electrophysiology, represents a powerful and versatile toolbox to stimulate, modulate, and record ion channel activity from membrane fragments and whole cells. The electrophysiological readout can be combined with fluorescent or optogenetic methods and allows for ultrafast solution exchanges using specialized microfluidic tools. A hallmark of manual patch clamp is the intentional selection of individual cells for recording, often an essential prerequisite to generate meaningful data. So far, available automation solutions rely on random cell usage in the closed environment of a chip and thus sacrifice much of this versatility by design. To parallelize and automate the traditional patch clamp technique while perpetuating the full versatility of the method, we developed an approach to automation, which is based on active cell handling and targeted electrode placement rather than on random processes. This is achieved through an automated pipette positioning system, which guides the tips of recording pipettes with micrometer precision to a microfluidic cell handling device. Using a patch pipette array mounted on a conventional micromanipulator, our automated patch clamp process mimics the original manual patch clamp as closely as possible, yet achieving a configuration where recordings are obtained from many patch electrodes in parallel. In addition, our implementation is extensible by design to allow the easy integration of specialized equipment such as ultrafast compound application tools. The resulting system offers fully automated patch clamp on purposely selected cells and combines high-quality gigaseal recordings with solution switching in the millisecond timescale.
Tuszynski, Tobias; Rullmann, Michael; Luthardt, Julia; Butzke, Daniel; Tiepolt, Solveig; Gertz, Hermann-Josef; Hesse, Swen; Seese, Anita; Lobsien, Donald; Sabri, Osama; Barthel, Henryk
2016-06-01
For regional quantification of nuclear brain imaging data, defining volumes of interest (VOIs) by hand is still the gold standard. As this procedure is time-consuming and operator-dependent, a variety of software tools for automated identification of neuroanatomical structures were developed. As the quality and performance of those tools are poorly investigated so far in analyzing amyloid PET data, we compared in this project four algorithms for automated VOI definition (HERMES Brass, two PMOD approaches, and FreeSurfer) against the conventional method. We systematically analyzed florbetaben brain PET and MRI data of ten patients with probable Alzheimer's dementia (AD) and ten age-matched healthy controls (HCs) collected in a previous clinical study. VOIs were manually defined on the data as well as through the four automated workflows. Standardized uptake value ratios (SUVRs) with the cerebellar cortex as a reference region were obtained for each VOI. SUVR comparisons between ADs and HCs were carried out using Mann-Whitney-U tests, and effect sizes (Cohen's d) were calculated. SUVRs of automatically generated VOIs were correlated with SUVRs of conventionally derived VOIs (Pearson's tests). The composite neocortex SUVRs obtained by manually defined VOIs were significantly higher for ADs vs. HCs (p=0.010, d=1.53). This was also the case for the four tested automated approaches which achieved effect sizes of d=1.38 to d=1.62. SUVRs of automatically generated VOIs correlated significantly with those of the hand-drawn VOIs in a number of brain regions, with regional differences in the degree of these correlations. Best overall correlation was observed in the lateral temporal VOI for all tested software tools (r=0.82 to r=0.95, p<0.001). Automated VOI definition by the software tools tested has a great potential to substitute for the current standard procedure to manually define VOIs in β-amyloid PET data analysis.
Unsupervised Fault Diagnosis of a Gear Transmission Chain Using a Deep Belief Network
He, Jun; Yang, Shixi; Gan, Chunbiao
2017-01-01
Artificial intelligence (AI) techniques, which can effectively analyze massive amounts of fault data and automatically provide accurate diagnosis results, have been widely applied to fault diagnosis of rotating machinery. Conventional AI methods are applied using features selected by a human operator, which are manually extracted based on diagnostic techniques and field expertise. However, developing robust features for each diagnostic purpose is often labour-intensive and time-consuming, and the features extracted for one specific task may be unsuitable for others. In this paper, a novel AI method based on a deep belief network (DBN) is proposed for the unsupervised fault diagnosis of a gear transmission chain, and the genetic algorithm is used to optimize the structural parameters of the network. Compared to the conventional AI methods, the proposed method can adaptively exploit robust features related to the faults by unsupervised feature learning, thus requires less prior knowledge about signal processing techniques and diagnostic expertise. Besides, it is more powerful at modelling complex structured data. The effectiveness of the proposed method is validated using datasets from rolling bearings and gearbox. To show the superiority of the proposed method, its performance is compared with two well-known classifiers, i.e., back propagation neural network (BPNN) and support vector machine (SVM). The fault classification accuracies are 99.26% for rolling bearings and 100% for gearbox when using the proposed method, which are much higher than that of the other two methods. PMID:28677638
Unsupervised Fault Diagnosis of a Gear Transmission Chain Using a Deep Belief Network.
He, Jun; Yang, Shixi; Gan, Chunbiao
2017-07-04
Artificial intelligence (AI) techniques, which can effectively analyze massive amounts of fault data and automatically provide accurate diagnosis results, have been widely applied to fault diagnosis of rotating machinery. Conventional AI methods are applied using features selected by a human operator, which are manually extracted based on diagnostic techniques and field expertise. However, developing robust features for each diagnostic purpose is often labour-intensive and time-consuming, and the features extracted for one specific task may be unsuitable for others. In this paper, a novel AI method based on a deep belief network (DBN) is proposed for the unsupervised fault diagnosis of a gear transmission chain, and the genetic algorithm is used to optimize the structural parameters of the network. Compared to the conventional AI methods, the proposed method can adaptively exploit robust features related to the faults by unsupervised feature learning, thus requires less prior knowledge about signal processing techniques and diagnostic expertise. Besides, it is more powerful at modelling complex structured data. The effectiveness of the proposed method is validated using datasets from rolling bearings and gearbox. To show the superiority of the proposed method, its performance is compared with two well-known classifiers, i.e., back propagation neural network (BPNN) and support vector machine (SVM). The fault classification accuracies are 99.26% for rolling bearings and 100% for gearbox when using the proposed method, which are much higher than that of the other two methods.
Validity of a manual soft tissue profile prediction method following mandibular setback osteotomy.
Kolokitha, Olga-Elpis
2007-10-01
The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication.
Deep Learning for Automated Extraction of Primary Sites from Cancer Pathology Reports
Qiu, John; Yoon, Hong-Jun; Fearn, Paul A.; ...
2017-05-03
Pathology reports are a primary source of information for cancer registries which process high volumes of free-text reports annually. Information extraction and coding is a manual, labor-intensive process. Here in this study we investigated deep learning and a convolutional neural network (CNN), for extracting ICDO- 3 topographic codes from a corpus of breast and lung cancer pathology reports. We performed two experiments, using a CNN and a more conventional term frequency vector approach, to assess the effects of class prevalence and inter-class transfer learning. The experiments were based on a set of 942 pathology reports with human expert annotations asmore » the gold standard. CNN performance was compared against a more conventional term frequency vector space approach. We observed that the deep learning models consistently outperformed the conventional approaches in the class prevalence experiment, resulting in micro and macro-F score increases of up to 0.132 and 0.226 respectively when class labels were well populated. Specifically, the best performing CNN achieved a micro-F score of 0.722 over 12 ICD-O-3 topography codes. Transfer learning provided a consistent but modest performance boost for the deep learning methods but trends were contingent on CNN method and cancer site. Finally, these encouraging results demonstrate the potential of deep learning for automated abstraction of pathology reports.« less
Deep Learning for Automated Extraction of Primary Sites from Cancer Pathology Reports
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qiu, John; Yoon, Hong-Jun; Fearn, Paul A.
Pathology reports are a primary source of information for cancer registries which process high volumes of free-text reports annually. Information extraction and coding is a manual, labor-intensive process. Here in this study we investigated deep learning and a convolutional neural network (CNN), for extracting ICDO- 3 topographic codes from a corpus of breast and lung cancer pathology reports. We performed two experiments, using a CNN and a more conventional term frequency vector approach, to assess the effects of class prevalence and inter-class transfer learning. The experiments were based on a set of 942 pathology reports with human expert annotations asmore » the gold standard. CNN performance was compared against a more conventional term frequency vector space approach. We observed that the deep learning models consistently outperformed the conventional approaches in the class prevalence experiment, resulting in micro and macro-F score increases of up to 0.132 and 0.226 respectively when class labels were well populated. Specifically, the best performing CNN achieved a micro-F score of 0.722 over 12 ICD-O-3 topography codes. Transfer learning provided a consistent but modest performance boost for the deep learning methods but trends were contingent on CNN method and cancer site. Finally, these encouraging results demonstrate the potential of deep learning for automated abstraction of pathology reports.« less
Validity of radiographic assessment of the knee joint space using automatic image analysis.
Komatsu, Daigo; Hasegawa, Yukiharu; Kojima, Toshihisa; Seki, Taisuke; Ikeuchi, Kazuma; Takegami, Yasuhiko; Amano, Takafumi; Higuchi, Yoshitoshi; Kasai, Takehiro; Ishiguro, Naoki
2016-09-01
The present study investigated whether there were differences between automatic and manual measurements of the minimum joint space width (mJSW) on knee radiographs. Knee radiographs of 324 participants in a systematic health screening were analyzed using the following three methods: manual measurement of film-based radiographs (Manual), manual measurement of digitized radiographs (Digital), and automatic measurement of digitized radiographs (Auto). The mean mJSWs on the medial and lateral sides of the knees were determined using each method, and measurement reliability was evaluated using intra-class correlation coefficients. Measurement errors were compared between normal knees and knees with radiographic osteoarthritis. All three methods demonstrated good reliability, although the reliability was slightly lower with the Manual method than with the other methods. On the medial and lateral sides of the knees, the mJSWs were the largest in the Manual method and the smallest in the Auto method. The measurement errors of each method were significantly larger for normal knees than for radiographic osteoarthritis knees. The mJSW measurements are more accurate and reliable with the Auto method than with the Manual or Digital method, especially for normal knees. Therefore, the Auto method is ideal for the assessment of the knee joint space.
Marinova, Mariela; Artusi, Carlo; Brugnolo, Laura; Antonelli, Giorgia; Zaninotto, Martina; Plebani, Mario
2013-11-01
Although, due to its high specificity and sensitivity, LC-MS/MS is an efficient technique for the routine determination of immunosuppressants in whole blood, it involves time-consuming manual sample preparation. The aim of the present study was therefore to develop an automated sample-preparation protocol for the quantification of sirolimus, everolimus and tacrolimus by LC-MS/MS using a liquid handling platform. Six-level commercially available blood calibrators were used for assay development, while four quality control materials and three blood samples from patients under immunosuppressant treatment were employed for the evaluation of imprecision. Barcode reading, sample re-suspension, transfer of whole blood samples into 96-well plates, addition of internal standard solution, mixing, and protein precipitation were performed with a liquid handling platform. After plate filtration, the deproteinised supernatants were submitted for SPE on-line. The only manual steps in the entire process were de-capping of the tubes, and transfer of the well plates to the HPLC autosampler. Calibration curves were linear throughout the selected ranges. The imprecision and accuracy data for all analytes were highly satisfactory. The agreement between the results obtained with manual and those obtained with automated sample preparation was optimal (n=390, r=0.96). In daily routine (100 patient samples) the typical overall total turnaround time was less than 6h. Our findings indicate that the proposed analytical system is suitable for routine analysis, since it is straightforward and precise. Furthermore, it incurs less manual workload and less risk of error in the quantification of whole blood immunosuppressant concentrations than conventional methods. © 2013.
Krishna Kumar, P; Araki, Tadashi; Rajan, Jeny; Saba, Luca; Lavra, Francesco; Ikeda, Nobutaka; Sharma, Aditya M; Shafique, Shoaib; Nicolaides, Andrew; Laird, John R; Gupta, Ajay; Suri, Jasjit S
2017-08-01
Monitoring of cerebrovascular diseases via carotid ultrasound has started to become a routine. The measurement of image-based lumen diameter (LD) or inter-adventitial diameter (IAD) is a promising approach for quantification of the degree of stenosis. The manual measurements of LD/IAD are not reliable, subjective and slow. The curvature associated with the vessels along with non-uniformity in the plaque growth poses further challenges. This study uses a novel and generalized approach for automated LD and IAD measurement based on a combination of spatial transformation and scale-space. In this iterative procedure, the scale-space is first used to get the lumen axis which is then used with spatial image transformation paradigm to get a transformed image. The scale-space is then reapplied to retrieve the lumen region and boundary in the transformed framework. Then, inverse transformation is applied to display the results in original image framework. Two hundred and two patients' left and right common carotid artery (404 carotid images) B-mode ultrasound images were retrospectively analyzed. The validation of our algorithm has done against the two manual expert tracings. The coefficient of correlation between the two manual tracings for LD was 0.98 (p < 0.0001) and 0.99 (p < 0.0001), respectively. The precision of merit between the manual expert tracings and the automated system was 97.7 and 98.7%, respectively. The experimental analysis demonstrated superior performance of the proposed method over conventional approaches. Several statistical tests demonstrated the stability and reliability of the automated system.
Robust keyword retrieval method for OCRed text
NASA Astrophysics Data System (ADS)
Fujii, Yusaku; Takebe, Hiroaki; Tanaka, Hiroshi; Hotta, Yoshinobu
2011-01-01
Document management systems have become important because of the growing popularity of electronic filing of documents and scanning of books, magazines, manuals, etc., through a scanner or a digital camera, for storage or reading on a PC or an electronic book. Text information acquired by optical character recognition (OCR) is usually added to the electronic documents for document retrieval. Since texts generated by OCR generally include character recognition errors, robust retrieval methods have been introduced to overcome this problem. In this paper, we propose a retrieval method that is robust against both character segmentation and recognition errors. In the proposed method, the insertion of noise characters and dropping of characters in the keyword retrieval enables robustness against character segmentation errors, and character substitution in the keyword of the recognition candidate for each character in OCR or any other character enables robustness against character recognition errors. The recall rate of the proposed method was 15% higher than that of the conventional method. However, the precision rate was 64% lower.
Forensic Facial Reconstruction: The Final Frontier.
Gupta, Sonia; Gupta, Vineeta; Vij, Hitesh; Vij, Ruchieka; Tyagi, Nutan
2015-09-01
Forensic facial reconstruction can be used to identify unknown human remains when other techniques fail. Through this article, we attempt to review the different methods of facial reconstruction reported in literature. There are several techniques of doing facial reconstruction, which vary from two dimensional drawings to three dimensional clay models. With the advancement in 3D technology, a rapid, efficient and cost effective computerized 3D forensic facial reconstruction method has been developed which has brought down the degree of error previously encountered. There are several methods of manual facial reconstruction but the combination Manchester method has been reported to be the best and most accurate method for the positive recognition of an individual. Recognition allows the involved government agencies to make a list of suspected victims'. This list can then be narrowed down and a positive identification may be given by the more conventional method of forensic medicine. Facial reconstruction allows visual identification by the individual's family and associates to become easy and more definite.
Ali, Muhammad Hassaan; Ullah, Samee; Javaid, Usman; Javaid, Mamoona; Jamal, Samreen; Butt, Nadeem Hafeez
2017-10-01
To perform a meta-analysis on the precision and safety of femtosecond laser-assisted anterior capsulotomy versus conventional manual continuous curvilinear capsulorrhexis. This meta-analysis was conducted from February 2010 to November 2014. Literature search on PubMed, Google Scholar, ExcerptaMedica database and Cochrane Library was done to identify randomised controlled trials and case-control studies. SPSS 20 was used for data analysis. Of the 10 articles included, there were 3(30%) randomised controlled trials and 7(70%) non-randomised controlled trials. The meta-analysis was based on a total of 2,882eyes. Of them, 1,498(51.97%) underwent femtosecond laser-assisted capsulotomy and 1,384(48.02%) underwent manual continuous curvilinear capsulorrhexis. The diameter of the capsulotomy and the rates of anterior capsule tear showed no statistical difference between the femtosecond laser group and the manual capsulorrhexis group (p=0.29 and p=0.68). In terms of circularity of capsulotomy, femtosecond laser group had a more significant advantage than the manual capsulorrhexis group (p<0.001). Femtosecond laser performed capsulotomy with more precision and higher reliability than the manual continuous curvilinear capsulorrhexis.
Han, Xu; Kim, Jung-jae; Kwoh, Chee Keong
2016-01-01
Biomedical text mining may target various kinds of valuable information embedded in the literature, but a critical obstacle to the extension of the mining targets is the cost of manual construction of labeled data, which are required for state-of-the-art supervised learning systems. Active learning is to choose the most informative documents for the supervised learning in order to reduce the amount of required manual annotations. Previous works of active learning, however, focused on the tasks of entity recognition and protein-protein interactions, but not on event extraction tasks for multiple event types. They also did not consider the evidence of event participants, which might be a clue for the presence of events in unlabeled documents. Moreover, the confidence scores of events produced by event extraction systems are not reliable for ranking documents in terms of informativity for supervised learning. We here propose a novel committee-based active learning method that supports multi-event extraction tasks and employs a new statistical method for informativity estimation instead of using the confidence scores from event extraction systems. Our method is based on a committee of two systems as follows: We first employ an event extraction system to filter potential false negatives among unlabeled documents, from which the system does not extract any event. We then develop a statistical method to rank the potential false negatives of unlabeled documents 1) by using a language model that measures the probabilities of the expression of multiple events in documents and 2) by using a named entity recognition system that locates the named entities that can be event arguments (e.g. proteins). The proposed method further deals with unknown words in test data by using word similarity measures. We also apply our active learning method for the task of named entity recognition. We evaluate the proposed method against the BioNLP Shared Tasks datasets, and show that our method can achieve better performance than such previous methods as entropy and Gibbs error based methods and a conventional committee-based method. We also show that the incorporation of named entity recognition into the active learning for event extraction and the unknown word handling further improve the active learning method. In addition, the adaptation of the active learning method into named entity recognition tasks also improves the document selection for manual annotation of named entities.
Tabard-Fougère, Anne; Rose-Dulcina, Kevin; Pittet, Vincent; Dayer, Romain; Vuillerme, Nicolas; Armand, Stéphane
2018-02-01
Electromyography (EMG) is an important parameter in Clinical Gait Analysis (CGA), and is generally interpreted with timing of activation. EMG amplitude comparisons between individuals, muscles or days need normalization. There is no consensus on existing methods. The gold standard, maximum voluntary isometric contraction (MVIC), is not adapted to pathological populations because patients are often unable to perform an MVIC. The normalization method inspired by the isometric grade 3 of manual muscle testing (isoMMT3), which is the ability of a muscle to maintain a position against gravity, could be an interesting alternative. The aim of this study was to evaluate the within- and between-day reliability of the isoMMT3 EMG normalizing method during gait compared with the conventional MVIC method. Lower limb muscles EMG (gluteus medius, rectus femoris, tibialis anterior, semitendinosus) were recorded bilaterally in nine healthy participants (five males, aged 29.7±6.2years, BMI 22.7±3.3kgm -2 ) giving a total of 18 independent legs. Three repeated measurements of the isoMMT3 and MVIC exercises were performed with an EMG recording. EMG amplitude of the muscles during gait was normalized by these two methods. This protocol was repeated one week later. Within- and between-day reliability of normalization tasks were similar for isoMMT3 and MVIC methods. Within- and between-day reliability of gait EMG normalized by isoMMT3 was higher than with MVIC normalization. These results indicate that EMG normalization using isoMMT3 is a reliable method with no special equipment needed and will support CGA interpretation. The next step will be to evaluate this method in pathological populations. Copyright © 2017 Elsevier B.V. All rights reserved.
Pirat, Bahar; McCulloch, Marti L; Zoghbi, William A
2006-09-01
This study sought to demonstrate that a novel speckle-tracking method can be used to assess right ventricular (RV) global and regional systolic function. Fifty-eight patients with pulmonary arterial hypertension (11 men; mean age 53 +/- 14 years) and 19 age-matched controls were studied. Echocardiographic images in apical planes were analyzed by conventional manual tracing for volumes and ejection fractions and by novel software (Axius Velocity Vector Imaging). Myocardial velocity, strain rate, and strain were determined at the basal, mid, and apical segments of the RV free wall and ventricular septum by Velocity Vector Imaging. RV volumes and ejection fractions obtained with manual tracing correlated strongly with the same indexes obtained by the Velocity Vector Imaging method in all subjects (r = 0.95 to 0.98, p < 0.001 for all). Peak systolic myocardial velocities, strain rate, and strain were significantly impaired in patients with pulmonary arterial hypertension compared with controls and were most altered in patients with the most severe pulmonary arterial hypertension (p < 0.05 for all). Pulmonary artery systolic pressure and a Doppler index of pulmonary vascular resistance were independent predictors of RV strain (r = -0.61 and r = -0.65, respectively, p < 0.05 for both). In conclusion, the new automated Velocity Vector Imaging method provides simultaneous quantitation of global and regional RV function that is angle independent and can be applied retrospectively to already stored digital images.
Natural Language Processing As an Alternative to Manual Reporting of Colonoscopy Quality Metrics
RAJU, GOTTUMUKKALA S.; LUM, PHILLIP J.; SLACK, REBECCA; THIRUMURTHI, SELVI; LYNCH, PATRICK M.; MILLER, ETHAN; WESTON, BRIAN R.; DAVILA, MARTA L.; BHUTANI, MANOOP S.; SHAFI, MEHNAZ A.; BRESALIER, ROBERT S.; DEKOVICH, ALEXANDER A.; LEE, JEFFREY H.; GUHA, SUSHOVAN; PANDE, MALA; BLECHACZ, BORIS; RASHID, ASIF; ROUTBORT, MARK; SHUTTLESWORTH, GLADIS; MISHRA, LOPA; STROEHLEIN, JOHN R.; ROSS, WILLIAM A.
2015-01-01
BACKGROUND & AIMS The adenoma detection rate (ADR) is a quality metric tied to interval colon cancer occurrence. However, manual extraction of data to calculate and track the ADR in clinical practice is labor-intensive. To overcome this difficulty, we developed a natural language processing (NLP) method to identify patients, who underwent their first screening colonoscopy, identify adenomas and sessile serrated adenomas (SSA). We compared the NLP generated results with that of manual data extraction to test the accuracy of NLP, and report on colonoscopy quality metrics using NLP. METHODS Identification of screening colonoscopies using NLP was compared with that using the manual method for 12,748 patients who underwent colonoscopies from July 2010 to February 2013. Also, identification of adenomas and SSAs using NLP was compared with that using the manual method with 2259 matched patient records. Colonoscopy ADRs using these methods were generated for each physician. RESULTS NLP correctly identified 91.3% of the screening examinations, whereas the manual method identified 87.8% of them. Both the manual method and NLP correctly identified examinations of patients with adenomas and SSAs in the matched records almost perfectly. Both NLP and manual method produce comparable values for ADR for each endoscopist as well as the group as a whole. CONCLUSIONS NLP can correctly identify screening colonoscopies, accurately identify adenomas and SSAs in a pathology database, and provide real-time quality metrics for colonoscopy. PMID:25910665
Iyatomi, Hitoshi; Oka, Hiroshi; Saito, Masataka; Miyake, Ayako; Kimoto, Masayuki; Yamagami, Jun; Kobayashi, Seiichiro; Tanikawa, Akiko; Hagiwara, Masafumi; Ogawa, Koichi; Argenziano, Giuseppe; Soyer, H Peter; Tanaka, Masaru
2006-04-01
The aims of this study were to provide a quantitative assessment of the tumour area extracted by dermatologists and to evaluate computer-based methods from dermoscopy images for refining a computer-based melanoma diagnostic system. Dermoscopic images of 188 Clark naevi, 56 Reed naevi and 75 melanomas were examined. Five dermatologists manually drew the border of each lesion with a tablet computer. The inter-observer variability was evaluated and the standard tumour area (STA) for each dermoscopy image was defined. Manual extractions by 10 non-medical individuals and by two computer-based methods were evaluated with STA-based assessment criteria: precision and recall. Our new computer-based method introduced the region-growing approach in order to yield results close to those obtained by dermatologists. The effectiveness of our extraction method with regard to diagnostic accuracy was evaluated. Two linear classifiers were built using the results of conventional and new computer-based tumour area extraction methods. The final diagnostic accuracy was evaluated by drawing the receiver operating curve (ROC) of each classifier, and the area under each ROC was evaluated. The standard deviations of the tumour area extracted by five dermatologists and 10 non-medical individuals were 8.9% and 10.7%, respectively. After assessment of the extraction results by dermatologists, the STA was defined as the area that was selected by more than two dermatologists. Dermatologists selected the melanoma area with statistically smaller divergence than that of Clark naevus or Reed naevus (P = 0.05). By contrast, non-medical individuals did not show this difference. Our new computer-based extraction algorithm showed superior performance (precision, 94.1%; recall, 95.3%) to the conventional thresholding method (precision, 99.5%; recall, 87.6%). These results indicate that our new algorithm extracted a tumour area close to that obtained by dermatologists and, in particular, the border part of the tumour was adequately extracted. With this refinement, the area under the ROC increased from 0.795 to 0.875 and the diagnostic accuracy showed an increase of approximately 20% in specificity when the sensitivity was 80%. It can be concluded that our computer-based tumour extraction algorithm extracted almost the same area as that obtained by dermatologists and provided improved computer-based diagnostic accuracy.
Witt, Claudia M; Michalsen, Andreas; Roll, Stephanie; Morandi, Antonio; Gupta, Shivnarain; Rosenberg, Mark; Kronpass, Ludwig; Stapelfeldt, Elmar; Hissar, Syed; Müller, Matthias; Kessler, Christian
2013-05-23
Traditional Indian Ayurvedic medicine uses complex treatment approaches, including manual therapies, lifestyle and nutritional advice, dietary supplements, medication, yoga, and purification techniques. Ayurvedic strategies are often used to treat osteoarthritis (OA) of the knee; however, no systematic data are available on their effectiveness in comparison with standard care. The aim of this study is to evaluate the effectiveness of complex Ayurvedic treatment in comparison with conventional methods of treating OA symptoms in patients with knee osteoarthritis. In a prospective, multicenter, randomized controlled trial, 150 patients between 40 and 70 years, diagnosed with osteoarthritis of the knee, following American College of Rheumatology criteria and an average pain intensity of ≥40 mm on a 100 mm visual analog scale in the affected knee at baseline will be randomized into two groups. In the Ayurveda group, treatment will include tailored combinations of manual treatments, massages, dietary and lifestyle advice, consideration of selected foods, nutritional supplements, yoga posture advice, and knee massage. Patients in the conventional group will receive self-care advice, pain medication, weight-loss advice (if overweight), and physiotherapy following current international guidelines. Both groups will receive 15 treatment sessions over 12 weeks. Outcomes will be evaluated after 6 and 12 weeks and 6 and 12 months. The primary endpoint is a change in the score on the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) after 12 weeks. Secondary outcome measurements will use WOMAC subscales, a pain disability index, a visual analog scale for pain and sleep quality, a pain experience scale, a quality-of-life index, a profile of mood states, and Likert scales for patient satisfaction, patient diaries, and safety. Using an adapted PRECIS scale, the trial was identified as lying mainly in the middle of the efficacy-effectiveness continuum. This trial is the first to compare the effectiveness of a complex Ayurvedic intervention with a complex conventional intervention in a Western medical setting in patients with knee osteoarthritis. During the trial design, aspects of efficacy and effectiveness were discussed. The resulting design is a compromise between rigor and pragmatism. NCT01225133.
Ozhinsky, Eugene; Vigneron, Daniel B; Nelson, Sarah J
2011-04-01
To develop a technique for optimizing coverage of brain 3D (1) H magnetic resonance spectroscopic imaging (MRSI) by automatic placement of outer-volume suppression (OVS) saturation bands (sat bands) and to compare the performance for point-resolved spectroscopic sequence (PRESS) MRSI protocols with manual and automatic placement of sat bands. The automated OVS procedure includes the acquisition of anatomic images from the head, obtaining brain and lipid tissue maps, calculating optimal sat band placement, and then using those optimized parameters during the MRSI acquisition. The data were analyzed to quantify brain coverage volume and data quality. 3D PRESS MRSI data were acquired from three healthy volunteers and 29 patients using protocols that included either manual or automatic sat band placement. On average, the automatic sat band placement allowed the acquisition of PRESS MRSI data from 2.7 times larger brain volumes than the conventional method while maintaining data quality. The technique developed helps solve two of the most significant problems with brain PRESS MRSI acquisitions: limited brain coverage and difficulty in prescription. This new method will facilitate routine clinical brain 3D MRSI exams and will be important for performing serial evaluation of response to therapy in patients with brain tumors and other neurological diseases. Copyright © 2011 Wiley-Liss, Inc.
Decapsulation Method for Flip Chips with Ceramics in Microelectronic Packaging
NASA Astrophysics Data System (ADS)
Shih, T. I.; Duh, J. G.
2008-06-01
The decapsulation of flip chips bonded to ceramic substrates is a challenging task in the packaging industry owing to the vulnerability of the chip surface during the process. In conventional methods, such as manual grinding and polishing, the solder bumps are easily damaged during the removal of underfill, and the thin chip may even be crushed due to mechanical stress. An efficient and reliable decapsulation method consisting of thermal and chemical processes was developed in this study. The surface quality of chips after solder removal is satisfactory for the existing solder rework procedure as well as for die-level failure analysis. The innovative processes included heat-sink and ceramic substrate removal, solder bump separation, and solder residue cleaning from the chip surface. In the last stage, particular temperatures were selected for the removal of eutectic Pb-Sn, high-lead, and lead-free solders considering their respective melting points.
Microprocessor-controlled hemodynamics: a step towards improved efficiency and safety.
Keogh, B E; Jacobs, J; Royston, D; Taylor, K M
1989-02-01
Manual titration of sodium nitroprusside (SNP) is widely used for treatment of hypertension following cardiac surgery. This study compared conventional manual control with control by a research prototype of an automatic infusion module based on a proportional plus integral plus derivative (PID) negative feedback loop. Two groups of coronary artery bypass patients requiring SNP for postoperative hypertension were studied prospectively. In the first group, hypertension was controlled by manual adjustment of the SNP infusion rate, and in the second, the infusion rate was controlled automatically. The actual and desired mean arterial pressures (MAP) over consecutive ten-second epochs were recorded during the period of infusion. The MAP was maintained within 10% of the desired MAP 45.8% of the time in the manual group, compared with 90.0% in the automatic group, and the mean percent error in the automatic group was significantly less than in the manual group (P less than 0.01). It is concluded that adoption of such systems will result in improved patient safety and may facilitate more effective distribution of nursing staff within intensive care units.
Nelwan, Erni J; Indrasanti, Evi; Sinto, Robert; Nurchaida, Farida; Sosrosumihardjo, Rustadi
2016-01-01
to evaluate the performance of Vitek2 compact machine (Biomerieux Inc. ver 04.02, France) in reference to manual methods for susceptibility test for Candida resistance among HIV/AIDS patients. a comparison study to evaluate Vitek2 compact machine (Biomerieux Inc. ver 04.02, France) in reference to manual methods for susceptibility test for Candida resistance among HIV/AIDS patient was done. Categorical agreement between manual disc diffusion and Vitek2 machine was calculated using predefined criteria. Time to susceptibility result for automated and manual methods were measured. there were 137 Candida isolates comprising eight Candida species with C.albicans and C. glabrata as the first (56.2%) and second (15.3%) most common species, respectively. For fluconazole drug, among the C. albicans, 2.6% was found resistant on manual disc diffusion methods and no resistant was determined by Vitek2 machine; whereas 100% C. krusei was identified as resistant on both methods. Resistant patterns for C. glabrata to fluconazole, voriconazole and amphotericin B were 52.4%, 23.8%, 23.8% vs. 9.5%, 9.5%, 4.8% respectively between manual diffusion disc methods and Vitek2 machine. Time to susceptibility result for automated methods compared to Vitex2 machine was shorter for all Candida species. there is a good categorical agreement between manual disc diffusion and Vitek2 machine, except for C. glabrata for measuring the antifungal resistant. Time to susceptibility result for automated methods is shorter for all Candida species.
Robotic surgery of locally advanced gastric cancer: a single-surgeon experience of 41 cases.
Vasilescu, C; Procopiuc, L
2012-01-01
The mainstay of curative gastric cancer treatment is open gastric resection with regional lymph node dissection. Minimally invasive surgery is yet to become an established technique with a well defined role. Robotic surgery has by-passed some of the limitations of conventional laparoscopy and has proven both safe and feasible. We present our initial experience with robotic surgery based on 41 gastric cancer patients. We especially wish to underline the advantages of the robotic system when performing the digestive tract anastomoses. We present the techniques of end-to-side eso-jejunoanastomoses (using a circular stapler or manual suture) and side-to-side eso-jejunoanastomoses. In our hands, the results with circular stapled anastomoses were good and we advocate against manual suturing when performing anastomoses in robotic surgery. Moreover, we recommend performing totally intracorporeal anastomoses which have a better post-operative outcome, especially in obese patients. We present three methods of realising the total intracorporeal eso-jejuno-anastomosis with a circular stapler: manual purse-string suture, using the OrVil and the double stapling technique. The eso-jejunoanastomosis is one of the most difficult steps in performing the total gastrectomy, but these techniques allow the surgeon to choose the best option for each case. We consider that surgeons who undertake total gastrectomies must have a special training in performing these anastomoses.
Detection of antipersonnel (AP) mines using mechatronics approach
NASA Astrophysics Data System (ADS)
Shahri, Ali M.; Naghdy, Fazel
1998-09-01
At present there are approximately 110 million land-mines scattered around the world in 64 countries. The clearance of these mines takes place manually. Unfortunately, on average for every 5000 mines cleared one mine clearer is killed. A Mine Detector Arm (MDA) using mechatronics approach is under development in this work. The robot arm imitates manual hand- prodding technique for mine detection. It inserts a bayonet into the soil and models the dynamics of the manipulator and environment parameters, such as stiffness variation in the soil to control the impact caused by contacting a stiff object. An explicit impact control scheme is applied as the main control scheme, while two different intelligent control methods are designed to deal with uncertainties and varying environmental parameters. Firstly, a neuro-fuzzy adaptive gain controller (NFAGC) is designed to adapt the force gain control according to the estimated environment stiffness. Then, an adaptive neuro-fuzzy plus PID controller is employed to switch from a conventional PID controller to neuro-fuzzy impact control (NFIC), when an impact is detected. The developed control schemes are validated through computer simulation and experimental work.
Valentine, Sarah E.; Borba, Christina P. C.; Dixon, Louise; Vaewsorn, Adin S.; Guajardo, Julia Gallegos; Resick, Patricia A.; Wiltsey-Stirman, Shannon; Marques, Luana
2016-01-01
Objective As part of a larger implementation trial for Cognitive Processing Therapy (CPT) for posttraumatic stress disorder (PTSD) in a community health center, we used formative evaluation to assess relations between iterative cultural adaption (for Spanish-speaking clients) and implementation outcomes (appropriateness & acceptability) for CPT. Method Qualitative data for the current study were gathered through multiple sources (providers: N=6; clients: N=22), including CPT therapy sessions, provider field notes, weekly consultation team meetings, and researcher field notes. Findings from conventional and directed content analysis of the data informed refinements to the CPT manual. Results Data-driven refinements included adaptations related to cultural context (i.e., language, regional variation in wording), urban context (e.g., crime/violence), and literacy level. Qualitative findings suggest improved appropriateness and acceptability of CPT for Spanish-speaking clients. Conclusion Our study reinforces the need for dual application of cultural adaptation and implementation science to address the PTSD treatment needs of Spanish-speaking clients. PMID:27378013
Pérez-Cruzado, David; Merchán-Baeza, Jose Antonio; González-Sánchez, Manuel; Cuesta-Vargas, Antonio I
2017-04-01
Stroke is a leading cause of disability in developed countries. One of the most widespread techniques in clinical practice is mirror therapy (MT). To determine the effectiveness of MT over other methods of intervention in the recovery of upper limb function in people who have had a stroke. A systematic review was conducted. The search string was established based on the last systematic review about MT that dated from 2009: "upper extremity" OR "upper limb "AND "mirror therapy" AND stroke. For this search Pubmed, Scopus and SciELO databases were used. Fifteen studies were included in the systematic review. Recovery of the upper limb, upper limb function and gross manual dexterity were frequently measured in these studies. In the primary variables in promoting recovery, MT alone showed better results in acute and chronic stroke patients in upper limb functioning than either conventional rehabilitation (CR) or CR plus MT. PROSPERO registration number: CRD42015026869. © 2016 Occupational Therapy Australia.
Hamerschmidt, Rogerio; Saab, Stephanie Sbizera; Carvalho, Bettina; Carmo, Carolina do
2018-01-01
Introduction Diode laser is a new alternative in stapes surgery for otosclerosis. The present study is the first to compare the short-term results of the surgery performed using diode laser to those obtained through the conventional fenestration technique. Objective To use audiometry to establish a comparative analysis between the functional results obtained through surgery for otosclerosis using diode laser and the conventional technique. Method Audiometric evaluation of 12 patients submitted to stapes surgery for otosclerosis, using diode laser or conventional fenestration by needle and drills, between 2014 and 2015. Each group was composed of 6 patients. Pre and post-operative measures were compared for three months in both groups. The speech recognition threshold, the air and bone conduction threshold, as well as the gap between them at 500 Hz, 1 KHz, 2 KHz and 4 KHz were measured. Results Significant difference in bone conduction and SRT was observed when compared post- and preoperative results in the diode group. However diode and conventional technique groups presented significant differences in air conduction and air-bone gap, suggesting that both can provide functional improvement. Conclusion Laser stapedotomy is a safe technique with good results. Both laser surgery and the conventional technique have improved the hearing of patients with a discreet advantage for the diode laser. Further prospective and randomized clinical trials are required to disclose all possible benefits of the stapes surgery using diode laser. PMID:29619098
Hamerschmidt, Rogerio; Saab, Stephanie Sbizera; Carvalho, Bettina; Carmo, Carolina do
2018-04-01
Introduction Diode laser is a new alternative in stapes surgery for otosclerosis. The present study is the first to compare the short-term results of the surgery performed using diode laser to those obtained through the conventional fenestration technique. Objective To use audiometry to establish a comparative analysis between the functional results obtained through surgery for otosclerosis using diode laser and the conventional technique. Method Audiometric evaluation of 12 patients submitted to stapes surgery for otosclerosis, using diode laser or conventional fenestration by needle and drills, between 2014 and 2015. Each group was composed of 6 patients. Pre and post-operative measures were compared for three months in both groups. The speech recognition threshold, the air and bone conduction threshold, as well as the gap between them at 500 Hz, 1 KHz, 2 KHz and 4 KHz were measured. Results Significant difference in bone conduction and SRT was observed when compared post- and preoperative results in the diode group. However diode and conventional technique groups presented significant differences in air conduction and air-bone gap, suggesting that both can provide functional improvement. Conclusion Laser stapedotomy is a safe technique with good results. Both laser surgery and the conventional technique have improved the hearing of patients with a discreet advantage for the diode laser. Further prospective and randomized clinical trials are required to disclose all possible benefits of the stapes surgery using diode laser.
Rhoden, D L; Hancock, G A; Miller, J M
1993-03-01
A numerical-code system for the reference identification of Staphylococcus species, Stomatococcus mucilaginosus, and Micrococcus species was established by using a selected panel of conventional biochemicals. Results from 824 cultures (289 eye isolate cultures, 147 reference strains, and 388 known control strains) were used to generate a list of 354 identification code numbers. Each six-digit code number was based on results from 18 conventional biochemical reactions. Seven milliliters of purple agar base with 1% sterile carbohydrate solution added was poured into 60-mm-diameter agar plates. All biochemical tests were inoculated with 1 drop of a heavy broth suspension, incubated at 35 degrees C, and read daily for 3 days. All reactions were read and interpreted by the method of Kloos et al. (G. A. Hebert, C. G. Crowder, G. A. Hancock, W. R. Jarvis, and C. Thornsberry, J. Clin. Microbiol. 26:1939-1949, 1988; W. E. Kloos and D. W. Lambe, Jr., P. 222-237, in A. Balows, W. J. Hansler, Jr., K. L. Herrmann, H. D. Isenberg, and H. J. Shadomy, ed., Manual of Clinical Microbiology, 5th ed., 1991). This modified reference identification method was 96 to 98% accurate and could have value in reference and public health laboratory settings.
Manjunatha, M; Annapurna, Kini; Sudhakar, V; Sunil Kumar, VC; Hiremath, Vinay Kumar; Shah, Ankur
2013-01-01
Introduction: The aim of any root canal treatment is to achieve a canal free of micro organisms, residual pulp remnants, debris and smear layer for the long term success of the procedure. Manual and automated instrumentation techniques along with proper irrigation regime is used to arrive at the aforementioned goal. Many authors focused on the preparation capabilities of various manual and rotary instruments but very few investigators stressed on the actual cleaning abilities of these instruments. Aims and objectives: This study was undertaken to evaluate the cleaning efficiency of manual K flex files and rotary Pro File systems in the root canals using a scanning electron microscope. Material and Methods:Thirty single rooted mandibular first premolars were divided into two groups and randomized (the manual group-M and the ProFile group-P) with respect to the preparation technique. The Manual group was hand instrumented with stainless steel K- Flexofiles by means of a conventional filing technique. The Pro File group was instrumented according to the manufacturer's instructions using a rotary handpiece. All canals were shaped and cleaned under frequent irrigation with EDTA. Final irrigation was carried out with 3 mL of normal saline solution to neutralize the action of the irrigant. The roots were split, one half of each tooth was selected for further SEM technique analysis and examined under the scanning electron microscope. The canal walls were quantitatively evaluated for the amount of debris and smear layer. The apical, middle and coronal regions of the canal surface, were graded (1-5) for debris and smear layer. A statistical analysis was performed using a Mann-Whitney Rank Sum test. ProFile performed least effective cleaning. Manual K-Flexofiles led to a grooved pattern. Results and Conclusion: A statistically significant difference was observed (p<0.05) between the two instrumentation techniques concerning the amount of debris and smear layer at the apical level. The manually filed canals had less debris and smear layer than those using a rotary technique. It was concluded from this study that none of the instrumentation techniques employed, produced the canal walls which were free of surface debris and smear layer. The manual instrumentation technique was better in cleaning the canals compared to the ProFile rotary Ni-Ti instruments despite the step-back technique used for manual instrumentation. How to cite this article: Manjunatha M, Kini A, Sudhakar V, Sunil K V C, Hiremath V K, Shah A. Smear Layer Evaluation on Root Canal Preparation with Manual and Rotary Techniques using EDTA as an Irrigant: A Scanning Electron Microscopy Study. J Int Oral Health 2013; 5(1):66-78. PMID:24155580
Testing an automated method to estimate ground-water recharge from streamflow records
Rutledge, A.T.; Daniel, C.C.
1994-01-01
The computer program, RORA, allows automated analysis of streamflow hydrographs to estimate ground-water recharge. Output from the program, which is based on the recession-curve-displacement method (often referred to as the Rorabaugh method, for whom the program is named), was compared to estimates of recharge obtained from a manual analysis of 156 years of streamflow record from 15 streamflow-gaging stations in the eastern United States. Statistical tests showed that there was no significant difference between paired estimates of annual recharge by the two methods. Tests of results produced by the four workers who performed the manual method showed that results can differ significantly between workers. Twenty-two percent of the variation between manual and automated estimates could be attributed to having different workers perform the manual method. The program RORA will produce estimates of recharge equivalent to estimates produced manually, greatly increase the speed od analysis, and reduce the subjectivity inherent in manual analysis.
Accuracy of digital and analogue cephalometric measurements assessed with the sandwich technique.
Santoro, Margherita; Jarjoura, Karim; Cangialosi, Thomas J
2006-03-01
The purpose of the study was to evaluate the accuracy of cephalometric measurements obtained with digital tracing software compared with equivalent hand-traced measurements. In the sandwich technique, a storage phosphor plate and a conventional radiographic film are placed in the same cassette and exposed simultaneously. The method eliminates positioning errors and potential differences associated with multiple radiographic exposures that affected previous studies. It was used to ensure the equivalence of the digital images to the hard copy radiographs. Cephalometric measurements instead of landmarks were the focus of this investigation in order to acquire data with direct clinical applications. The sample consisted of digital and analog radiographic images from 47 patients after orthodontic treatment. Nine cephalometric landmarks were identified and 13 measurements calculated by 1 operator, both manually and with digital tracing software. Measurement error was assessed for each method by duplicating measurements of 25 randomly selected radiographs and by using Pearson's correlation coefficient. A paired t test was used to detect differences between the manual and digital methods. An overall greater variability in the digital cephalometric measurements was found. Differences between the 2 methods for SNA, ANB, S-Go:N-Me, U1/L1, L1-GoGn, and N-ANS:ANS-Me were statistically significant (P < .05). However, only the U1/L1 and S-Go:N-Me measurements showed differences greater than 2 SE (P < .0001). The 2 tracing methods provide similar clinical results; therefore, efficient digital cephalometric software can be reliably chosen as a routine diagnostic tool. The user-friendly sandwich technique was effective as an option for interoffice communications.
DESIGN MANUAL: PHOSPHORUS REMOVAL
This manual summarizes process design information for the best developed methods for removing phosphorus from wastewater. his manual discusses several proven phosphorus removal methods, including phosphorus removal obtainable through biological activity as well as chemical precip...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Y; Tan, J; Jiang, S
Purpose: Plan specific quality assurance (QA) is an important step in high dose rate (HDR) brachytherapy to ensure the integrity of a treatment plan. The conventional approach is to assemble a set of plan screen-captures in a document and have an independent plan-checker to verify it. Not only is this approach cumbersome and time-consuming, using a document also limits the items that can be verified, hindering plan quality and patient safety. We have initiated efforts to develop a web-based HDR brachytherapy QA system called AutoBrachy QA, for comprehensive and efficient QA. This abstract reports a new plugin in this systemmore » for the QA of a cylinder HDR brachytherapy treatment. Methods: A cylinder plan QA module was developed using Python. It was plugged into our AutoBrachy QA system. This module extracted information from CT images and treatment plan. Image processing techniques were employed to obtain geometric parameters, e.g. cylinder diameter. A comprehensive set of eight geometrical and eight dosimetric features of the plan were validated against user specified planning parameter, such as prescription value, treatment depth and length, etc. A PDF document was generated, consisting of a summary QA sheet with all the QA results, as well as images showing plan details. Results: The cylinder QA program has been implemented in our clinic. To date, it has been used in 11 patient cases and was able to successfully perform QA tests in all of them. The QA program reduced the average plan QA time from 7 min using conventional manual approach to 0.5 min. Conclusion: Being a new module in our AutoBrachy QA system, an automated treatment plan QA module for cylinder HDR brachytherapy has been successfully developed and clinically implemented. This module improved clinical workflow and plan integrity compared to the conventional manual approach.« less
Reproducibility of CT bone densitometry: operator versus automated ROI definition.
Louis, O; Luypaert, R; Kalender, W; Osteaux, M
1988-05-01
Intrasubject reproducibility with repeated determination of vertebral mineral density from a given set of CT images was investigated. The region of interest (ROI) in 10 patient scans was selected by four independent operators either manually or with an automated procedure separating cortical and spongeous bone, the operators being requested to interact in ROI selection. The mean intrasubject variation was found to be much lower with the automated process (0.3 to 0.6%) than with the conventional method (2.5 to 5.2%). In a second study, 10 patients were examined twice to determine the reproducibility of CT slice selection by the operator. The errors were of the same order of magnitude as in ROI selection.
DOT National Transportation Integrated Search
2014-04-01
The objective of this project was to quantify the effectiveness of the rail inspection ground verification process. More specifically, : the project focused on comparing the effectiveness of conventional versus phased array probes to manually detect ...
Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit Ms
2018-01-01
To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p =0.005). Postoperative refractive cylinder was -0.89±0.35 D in group I and -0.64±0.36 D in group II ( p =0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio ( p <0.05) and modulation transfer function (MTF) ( p <0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) ( p <0.05). Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment.
Hartmann, Luise; Stephenson, Christine F; Verkamp, Stephanie R; Johnson, Krystal R; Burnworth, Bettina; Hammock, Kelle; Brodersen, Lisa Eidenschink; de Baca, Monica E; Wells, Denise A; Loken, Michael R; Zehentner, Barbara K
2014-12-01
Array comparative genomic hybridization (aCGH) has become a powerful tool for analyzing hematopoietic neoplasms and identifying genome-wide copy number changes in a single assay. aCGH also has superior resolution compared with fluorescence in situ hybridization (FISH) or conventional cytogenetics. Integration of single nucleotide polymorphism (SNP) probes with microarray analysis allows additional identification of acquired uniparental disomy, a copy neutral aberration with known potential to contribute to tumor pathogenesis. However, a limitation of microarray analysis has been the inability to detect clonal heterogeneity in a sample. This study comprised 16 samples (acute myeloid leukemia, myelodysplastic syndrome, chronic lymphocytic leukemia, plasma cell neoplasm) with complex cytogenetic features and evidence of clonal evolution. We used an integrated manual peak reassignment approach combining analysis of aCGH and SNP microarray data for characterization of subclonal abnormalities. We compared array findings with results obtained from conventional cytogenetic and FISH studies. Clonal heterogeneity was detected in 13 of 16 samples by microarray on the basis of log2 values. Use of the manual peak reassignment analysis approach improved resolution of the sample's clonal composition and genetic heterogeneity in 10 of 13 (77%) patients. Moreover, in 3 patients, clonal disease progression was revealed by array analysis that was not evident by cytogenetic or FISH studies. Genetic abnormalities originating from separate clonal subpopulations can be identified and further characterized by combining aCGH and SNP hybridization results from 1 integrated microarray chip by use of the manual peak reassignment technique. Its clinical utility in comparison to conventional cytogenetic or FISH studies is demonstrated. © 2014 American Association for Clinical Chemistry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, X; Li, S; Zheng, D
Purpose: Linac commissioning is a time consuming and labor intensive process, the streamline of which is highly desirable. In particular, manual measurement of output factors for a variety of field sizes and energy greatly hinders the commissioning efficiency. In this study, automated measurement of output factors was demonstrated as ‘one-click’ using data logging of an electrometer. Methods: Beams to be measured were created in the recording and verifying (R&V) system and configured for continuous delivery. An electrometer with an automatic data logging feature enabled continuous data collection for all fields without human intervention. The electrometer saved data into a spreadsheetmore » every 0.5 seconds. A Matlab program was developed to analyze the excel data to monitor and check the data quality. Results: For each photon energy, output factors were measured for five configurations, including open field and four wedges. Each configuration includes 72 fields sizes, ranging from 4×4 to 20×30 cm{sup 2}. Using automation, it took 50 minutes to complete the measurement of 72 field sizes, in contrast to 80 minutes when using the manual approach. The automation avoided the necessity of redundant Linac status checks between fields as in the manual approach. In fact, the only limiting factor in such automation is Linac overheating. The data collection beams in the R&V system are reusable, and the simplified process is less error-prone. In addition, our Matlab program extracted the output factors faithfully from data logging, and the discrepancy between the automatic and manual measurement is within ±0.3%. For two separate automated measurements 30 days apart, consistency check shows a discrepancy within ±1% for 6MV photon with a 60 degree wedge. Conclusion: Automated output factor measurements can save time by 40% when compared with conventional manual approach. This work laid ground for further improvement for the automation of Linac commissioning.« less
Digital forensic osteology--possibilities in cooperation with the Virtopsy project.
Verhoff, Marcel A; Ramsthaler, Frank; Krähahn, Jonathan; Deml, Ulf; Gille, Ralf J; Grabherr, Silke; Thali, Michael J; Kreutz, Kerstin
2008-01-30
The present study was carried out to check whether classic osteometric parameters can be determined from the 3D reconstructions of MSCT (multislice computed tomography) scans acquired in the context of the Virtopsy project. To this end, four isolated and macerated skulls were examined by six examiners. First the skulls were conventionally (manually) measured using 32 internationally accepted linear measurements. Then the skulls were scanned by the use of MSCT with slice thicknesses of 1.25 mm and 0.63 mm, and the 33 measurements were virtually determined on the digital 3D reconstructions of the skulls. The results of the traditional and the digital measurements were compared for each examiner to figure out variations. Furthermore, several parameters were measured on the cranium and postcranium during an autopsy and compared to the values that had been measured on a 3D reconstruction from a previously acquired postmortem MSCT scan. The results indicate that equivalent osteometric values can be obtained from digital 3D reconstructions from MSCT scans using a slice thickness of 1.25 mm, and from conventional manual examinations. The measurements taken from a corpse during an autopsy could also be validated with the methods used for the digital 3D reconstructions in the context of the Virtopsy project. Future aims are the assessment and biostatistical evaluation in respect to sex, age and stature of all data sets stored in the Virtopsy project so far, as well as of future data sets. Furthermore, a definition of new parameters, only measurable with the aid of MSCT data would be conceivable.
Bhagwat, Swarupa Nikhil; Sharma, Jayashree H; Jose, Julie; Modi, Charusmita J
2015-01-01
Context: The routine immunohematological tests can be performed by automated as well as manual techniques. These techniques have advantages and disadvantages inherent to them. Aims: The present study aims to compare the results of manual and automated techniques for blood grouping and crossmatching so as to validate the automated system effectively. Materials and Methods: A total of 1000 samples were subjected to blood grouping by the conventional tube technique (CTT) and the automated microplate LYRA system on Techno TwinStation. A total of 269 samples (multitransfused patients and multigravida females) were compared for 927 crossmatches by the CTT in indirect antiglobulin phase against the column agglutination technique (CAT) performed on Techno TwinStation. Results: For blood grouping, the study showed a concordance in results for 942/1000 samples (94.2%), discordance for 4/1000 (0.4%) samples and uninterpretable result for 54/1000 samples (5.4%). On resolution, the uninterpretable results reduced to 49/1000 samples (4.9%) with 951/1000 samples (95.1%) showing concordant results. For crossmatching, the automated CAT showed concordant results in 887/927 (95.6%) and discordant results in 3/927 (0.32%) crossmatches as compared to the CTT. Total 37/927 (3.9%) crossmatches were not interpretable by the automated technique. Conclusions: The automated system shows a high concordance of results with CTT and hence can be brought into routine use. However, the high proportion of uninterpretable results emphasizes on the fact that proper training and standardization are needed prior to its use. PMID:26417159
Dynamic CT myocardial perfusion imaging: performance of 3D semi-automated evaluation software.
Ebersberger, Ullrich; Marcus, Roy P; Schoepf, U Joseph; Lo, Gladys G; Wang, Yining; Blanke, Philipp; Geyer, Lucas L; Gray, J Cranston; McQuiston, Andrew D; Cho, Young Jun; Scheuering, Michael; Canstein, Christian; Nikolaou, Konstantin; Hoffmann, Ellen; Bamberg, Fabian
2014-01-01
To evaluate the performance of three-dimensional semi-automated evaluation software for the assessment of myocardial blood flow (MBF) and blood volume (MBV) at dynamic myocardial perfusion computed tomography (CT). Volume-based software relying on marginal space learning and probabilistic boosting tree-based contour fitting was applied to CT myocardial perfusion imaging data of 37 subjects. In addition, all image data were analysed manually and both approaches were compared with SPECT findings. Study endpoints included time of analysis and conventional measures of diagnostic accuracy. Of 592 analysable segments, 42 showed perfusion defects on SPECT. Average analysis times for the manual and software-based approaches were 49.1 ± 11.2 and 16.5 ± 3.7 min respectively (P < 0.01). There was strong agreement between the two measures of interest (MBF, ICC = 0.91, and MBV, ICC = 0.88, both P < 0.01) and no significant difference in MBF/MBV with respect to diagnostic accuracy between the two approaches for both MBF and MBV for manual versus software-based approach; respectively; all comparisons P > 0.05. Three-dimensional semi-automated evaluation of dynamic myocardial perfusion CT data provides similar measures and diagnostic accuracy to manual evaluation, albeit with substantially reduced analysis times. This capability may aid the integration of this test into clinical workflows. • Myocardial perfusion CT is attractive for comprehensive coronary heart disease assessment. • Traditional image analysis methods are cumbersome and time-consuming. • Automated 3D perfusion software shortens analysis times. • Automated 3D perfusion software increases standardisation of myocardial perfusion CT. • Automated, standardised analysis fosters myocardial perfusion CT integration into clinical practice.
A qualitative evaluation of scalpel skill teaching of podiatry students.
Causby, Ryan S; McDonnell, Michelle N; Reed, Lloyd; Fryer, Caroline E; Hillier, Susan L
2017-01-01
Degrees in health disciplines need a balance of theoretical knowledge and sufficient clinical practice to meet registration requirements, in particular those requiring specialist skills such as the use of scalpels and other small instruments, such as podiatry. However, despite this requirement there is a scarcity of literature and research to inform teaching of these particular manual clinical skills. Therefore, the aims of this study were to determine the current approaches being used to teach manual skills, in particular scalpel skills, in university podiatry programs in Australia and New Zealand, and to explore what issues, challenges and innovations exist. A qualitative study, consisting of semi-structured interviews with staff at eight university podiatry programs in Australia and New Zealand was undertaken to determine how these skills are taught and evaluated, and how poor performers are managed. A conventional content analysis technique was used to analyse and code interview data, with the resultant categories reported. Approaches to teaching manual clinical skills, in particular scalpel skills, appear to be consistent between university programs in Australia and New Zealand in utilising didactic-style content, demonstration, physical practice on inanimate objects and real skin, and often the use of supplementary audio-visual material. The main reported differences between programs were in methods and processes of practice, with controversy regarding the use of inanimate objects versus real skin for practice. Despite a lack of research and literature surrounding this topic, the approach to teaching is relatively consistent between programs with greatest disparity being the structure and duration of practice. Key issues for teaching staff in teaching manual skills were students' clinical exposure, motivation, levels of anxiety and dexterity.
Robotic positioning of standard electrophysiology catheters: a novel approach to catheter robotics.
Knight, Bradley; Ayers, Gregory M; Cohen, Todd J
2008-05-01
Robotic systems have been developed to manipulate and position electrophysiology (EP) catheters remotely. One limitation of existing systems is their requirement for specialized catheters or sheaths. We evaluated a system (Catheter Robotics Remote Catheter Manipulation System [RCMS], Catheter Robotics, Inc., Budd Lake, New Jersey) that manipulates conventional EP catheters placed through standard introducer sheaths. The remote controller functions much like the EP catheter handle, and the system permits repeated catheter disengagement for manual manipulation without requiring removal of the catheter from the body. This study tested the hypothesis that the RCMS would be able to safely and effectively position catheters at various intracardiac sites and obtain thresholds and electrograms similar to those obtained with manual catheter manipulation. Two identical 7 Fr catheters (Blazer II; Boston Scientific Corp., Natick, Massachusetts) were inserted into the right femoral veins of 6 mongrel dogs through separate, standard 7 Fr sheaths. The first catheter was manually placed at a right ventricular endocardial site. The second catheter handle was placed in the mating holder of the RCMS and moved to approximately the same site as the first catheter using the Catheter Robotics RCMS. The pacing threshold was determined for each catheter. This sequence was performed at 2 right atrial and 2 right ventricular sites. The distance between the manually and robotically placed catheters tips was measured, and pacing thresholds and His-bundle recordings were compared. The heart was inspected at necropsy for signs of cardiac perforation or injury. Compared to manual positioning, remote catheter placement produced the same pacing threshold at 7/24 sites, a lower threshold at 11/24 sites, and a higher threshold at only 6/24 sites (p > 0.05). The average distance between catheter tips was 0.46 +/- 0.32 cm (median 0.32, range 0.13-1.16 cm). There was no difference between right atrial and right ventricular sites (p > 0.05). His-bundle electrograms were equal in amplitude and timing. Further, the remote navigation catheter was able to be disengaged, manually manipulated, then reengaged in the robot without issue. There was no evidence of perforation. The Catheter Robotics remote catheter manipulation system, which uses conventional EP catheters and introducer sheaths, appears to be safe and effective at directing EP catheters to intracardiac sites and achieving pacing thresholds and electrograms equivalent to manually placed catheters. Further clinical studies are needed to confirm these observations.
Added, Marco Aurélio Nemitalla; Costa, Leonardo Oliveira Pena; Fukuda, Thiago Yukio; de Freitas, Diego Galace; Salomão, Evelyn Cassia; Monteiro, Renan Lima; Costa, Lucíola da Cunha Menezes
2013-10-24
Chronic nonspecific low back pain is a significant health condition with high prevalence worldwide and it is associated with enormous costs to society. Clinical practice guidelines show that many interventions are available to treat patients with chronic low back pain, but the vast majority of these interventions have a modest effect in reducing pain and disability. An intervention that has been widespread in recent years is the use of elastic bandages called Kinesio Taping. Although Kinesio Taping has been used extensively in clinical practice, current evidence does not support the use of this intervention; however these conclusions are based on a small number of underpowered studies. Therefore, questions remain about the effectiveness of the Kinesio Taping method as an additional treatment to interventions, such as conventional physiotherapy, that have already been recommended by the current clinical practice guidelines in robust and high-quality randomised controlled trials. We aim to determine the effectiveness of the addition of the use of Kinesio Taping in patients with chronic nonspecific low back pain who receive guideline-endorsed conventional physiotherapy. One hundred and forty-eight patients will be randomly allocated to receive either conventional physiotherapy, which consists of a combination of manual therapy techniques, general exercises, and specific stabilisation exercises (Guideline-Endorsed Conventional Physiotherapy Group) or to receive conventional physiotherapy with the addition of Kinesio Taping to the lumbar spine (Conventional Physiotherapy plus Kinesio Taping Group) over a period of 5 weeks (10 sessions of treatment). Clinical outcomes (pain intensity, disability and global perceived effect) will be collected at baseline and at 5 weeks, 3 months, and 6 months after randomisation. We will also collect satisfaction with care and adverse effects after treatment. Data will be collected by a blinded assessor. All statistical analysis will be conducted following the principles of intention to treat, and the effects of treatment will be calculated using Linear Mixed Models. The results of this study will provide new information about the usefulness of Kinesio Taping as an additional component of a guideline-endorsed physiotherapy program in patients with chronic nonspecific low back pain.
Aeronautical Information Publication (AIP) United States of America (14th ed : 1997)
DOT National Transportation Integrated Search
1997-01-30
The AIP is prepared in accordance with the Standards and Recommended Practices : (SARPS) of Annex 15 to the Convention on International Civil Aviation and the : Aeronautical Information Services Manual (ICAO Doc 8126). The AIP is made up : of three P...
Measurement of ciliary beat frequency using ultra-high resolution optical coherence tomography
NASA Astrophysics Data System (ADS)
Chen, Jason J.; Jing, Joseph C.; Su, Erica; Badger, Christopher; Coughlan, Carolyn A.; Chen, Zhongping; Wong, Brian J. F.
2016-02-01
Ciliated epithelial cells populate up to 80% of the surface area of the human airway and are responsible for mucociliary transport, which is the key protective mechanism that provides the first line of defense in the respiratory tract. Cilia beat in a rhythmic pattern and may be easily affected by allergens, pollutants, and pathogens, altering ciliary beat frequency (CBF) subsequently. Diseases including cystic fibrosis, chronic obstructive pulmonary disease, and primary ciliary dyskinesia may also decrease CBF. CBF is therefore a critical component of respiratory health. The current clinical method of measuring CBF is phase-contrast microscopy, which involves a tissue biopsy obtained via brushing of the nasal cavity. While this method is minimally invasive, the tissue sample must be oriented to display its profile view, making the visualization of a single layer of cilia challenging. In addition, the conventional method requires subjective analysis of CBF, e.g., manually counting by visual inspection. On the contrary, optical coherence tomography (OCT) has been used to study the retina in ophthalmology as well as vasculature in cardiology, and offers higher resolution than conventional computed tomography and magnetic resonance imaging. Based on this technology, our lab specifically developed an ultra-high resolution OCT system to image the microstructure of the ciliated epithelial cells. Doppler analysis was also performed to determine CBF. Lastly, we also developed a program that utilizes fast Fourier transform to determine CBF under phase-contrast microscopy, providing a more objective method compared to the current method.
Dose measurements in intraoral radiography using thermoluminescent dosimeters
NASA Astrophysics Data System (ADS)
Azorín, C.; Azorín, J.; Aguirre, F.; Rivera, T.
2015-01-01
The use of X-ray in medicine demands to expose the patient and the professional to the lowest radiation doses available in agreement with ALARA philosophy. The reference level for intraoral dental radiography is 7 mGy and, in Mexico, a number of examinations of this type are performed annually. It is considered that approximately 25% of all the X-rays examinations carried out in our country correspond to intraoral radiographies. In other hand, most of the intraoral X-ray equipment correspond to conventional radiological systems using film, which are developed as much manual as automatically. In this work the results of determining the doses received by the patients in intraoral radiological examinations made with different radiological systems using LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters are presented. In some conventional radiological systems using film, when films are developed manual or automatically, incident kerma up to 10.61 ± 0.74 mGv were determined. These values exceed that reference level suggested by the IAEA and in the Mexican standards for intraoral examinations.
Guidelines for preparing software user documentation
NASA Technical Reports Server (NTRS)
Miller, Diane F.
1987-01-01
Clear, easy-to-use software user's manuals make strong demands on special technical communication techniques. Principles and guidelines are given for analyzing the audience and dealing with wide-ranging backgrounds of potential users. Types of information to be included in a complete manual are suggested, with a technique for creating a user-oriented rather than process-oriented organization. Accuracy verification is emphasized. Simple tips are gievn for formatting for quick comprehension and reference, for deciding on packaging, for creating helpful illustrations and examples, and for setting up clear and consistent conventions. Simple guidelines are offered for writing clearly and concisely and for editing.
Robust estimation of carotid artery wall motion using the elasticity-based state-space approach.
Gao, Zhifan; Xiong, Huahua; Liu, Xin; Zhang, Heye; Ghista, Dhanjoo; Wu, Wanqing; Li, Shuo
2017-04-01
The dynamics of the carotid artery wall has been recognized as a valuable indicator to evaluate the status of atherosclerotic disease in the preclinical stage. However, it is still a challenge to accurately measure this dynamics from ultrasound images. This paper aims at developing an elasticity-based state-space approach for accurately measuring the two-dimensional motion of the carotid artery wall from the ultrasound imaging sequences. In our approach, we have employed a linear elasticity model of the carotid artery wall, and converted it into the state space equation. Then, the two-dimensional motion of carotid artery wall is computed by solving this state-space approach using the H ∞ filter and the block matching method. In addition, a parameter training strategy is proposed in this study for dealing with the parameter initialization problem. In our experiment, we have also developed an evaluation function to measure the tracking accuracy of the motion of the carotid artery wall by considering the influence of the sizes of the two blocks (acquired by our approach and the manual tracing) containing the same carotid wall tissue and their overlapping degree. Then, we have compared the performance of our approach with the manual traced results drawn by three medical physicians on 37 healthy subjects and 103 unhealthy subjects. The results have showed that our approach was highly correlated (Pearson's correlation coefficient equals 0.9897 for the radial motion and 0.9536 for the longitudinal motion), and agreed well (width the 95% confidence interval is 89.62 µm for the radial motion and 387.26 µm for the longitudinal motion) with the manual tracing method. We also compared our approach to the three kinds of previous methods, including conventional block matching methods, Kalman-based block matching methods and the optical flow. Altogether, we have been able to successfully demonstrate the efficacy of our elasticity-model based state-space approach (EBS) for more accurate tracking of the 2-dimensional motion of the carotid artery wall, towards more effective assessment of the status of atherosclerotic disease in the preclinical stage. Copyright © 2017 Elsevier B.V. All rights reserved.
Semi-automating the manual literature search for systematic reviews increases efficiency.
Chapman, Andrea L; Morgan, Laura C; Gartlehner, Gerald
2010-03-01
To minimise retrieval bias, manual literature searches are a key part of the search process of any systematic review. Considering the need to have accurate information, valid results of the manual literature search are essential to ensure scientific standards; likewise efficient approaches that minimise the amount of personnel time required to conduct a manual literature search are of great interest. The objective of this project was to determine the validity and efficiency of a new manual search method that utilises the scopus database. We used the traditional manual search approach as the gold standard to determine the validity and efficiency of the proposed scopus method. Outcome measures included completeness of article detection and personnel time involved. Using both methods independently, we compared the results based on accuracy of the results, validity and time spent conducting the search, efficiency. Regarding accuracy, the scopus method identified the same studies as the traditional approach indicating its validity. In terms of efficiency, using scopus led to a time saving of 62.5% compared with the traditional approach (3 h versus 8 h). The scopus method can significantly improve the efficiency of manual searches and thus of systematic reviews.
Choi, Sungwook; Kim, Myung-Ku; Kwon, Yong Suk; Kang, Hyunseong
2017-10-01
The purpose of this study was to compare the clinical outcomes and second-look arthroscopic findings of remnant preservation technique with those of conventional anterior cruciate ligament (ACL) reconstruction in single bundle ACL reconstructions. One hundred sixty two consecutive patients underwent ACL reconstruction by one surgeon, with 93 patients receiving remnant preservation technique (Group A) and 69 patients receiving conventional ACL reconstruction (Group B). The mean follow-up was 15months. Clinical outcomes were assessed using Lysholm scores and the International Knee Documentation Committee form (IKDC form) evaluation. Post-operative knee stability was evaluated through manual knee laxity evaluation, pivot-shift test, and a Telos device. Differences in post-operative stability (manual knee laxity, pivot shift test and Telos device) were not significant between the groups (p=0.681, p=0.610, p=0.696). And also no significant differences were noted with respect to the IKDC form and the latest Lysholm scores. But in the second-look arthroscopic findings, synovial coverage was confirmed to be excellent in 36% (22/61) of Group A patients and 23% (7/30) of Group B patients. ACL reconstruction with both techniques was found to result in acceptable stability, clinical outcomes and second-look arthroscopic findings. With regard to synovial coverage, the remnant reservation techniques were found to be superior to conventional ACL reconstruction. Level III, retrospective comparative study. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Sharif, Harlina Md; Hazumi, Hazman; Hafizuddin Meli, Rafiq
2018-01-01
3D imaging technologies have undergone massive revolution in recent years. Despite this rapid development, documentation of 3D cultural assets in Malaysia is still very much reliant upon conventional techniques such as measured drawings and manual photogrammetry. There is very little progress towards exploring new methods or advanced technologies to convert 3D cultural assets into 3D visual representation and visualization models that are easily accessible for information sharing. In recent years, however, the advent of computer vision (CV) algorithms make it possible to reconstruct 3D geometry of objects by using image sequences from digital cameras, which are then processed by web services and freeware applications. This paper presents a completed stage of an exploratory study that investigates the potentials of using CV automated image-based open-source software and web services to reconstruct and replicate cultural assets. By selecting an intricate wooden boat, Petalaindera, this study attempts to evaluate the efficiency of CV systems and compare it with the application of 3D laser scanning, which is known for its accuracy, efficiency and high cost. The final aim of this study is to compare the visual accuracy of 3D models generated by CV system, and 3D models produced by 3D scanning and manual photogrammetry for an intricate subject such as the Petalaindera. The final objective is to explore cost-effective methods that could provide fundamental guidelines on the best practice approach for digital heritage in Malaysia.
SMIF capability at Intel Mask Operation improves yield
NASA Astrophysics Data System (ADS)
Dam, Thuc H.; Pekny, Matt; Millino, Jim; Luu, Gibson; Melwani, Nitesh; Venkatramani, Aparna; Tavassoli, Malahat
2003-08-01
At Intel Mask Operations (IMO), Standard Mechanical Interface (SMIF) processing has been employed to reduce environmental particle contamination from manual handling-related activities. SMIF handling entailed the utilization of automated robotic transfers of photoblanks/reticles between SMIF pods, whereas conventional handling utilized manual pick transfers of masks between SMIF pods with intermediate storage in Toppan compacts. The SMIF-enabling units in IMO's process line included: (1) coater, (2) exposure, (3) developer, (4) dry etcher, and (5) inspection. Each unit is equipped with automated I/O port, environmentally enclosed processing chamber, and SMIF pods. Yield metrics were utilized to demonstrate the effectiveness and advantages of SMIF processing compared to manual processing. The areas focused in this paper were blank resist coating, binary front-end reticle processing and 2nd level PSM reticle processing. Results obtained from the investigation showed yield improvements in these areas.
Evaluating Unsupervised Methods to Size and Classify Suspended Particles Using Digital Holography
NASA Astrophysics Data System (ADS)
Davies, E. J.; Buscombe, D.; Graham, G.; Nimmo-Smith, A.
2013-12-01
The use of digital holography to image suspended particles in-situ using submersible systems is on the ascendancy. Such systems allow visualization of the in-focus particles without the depth-of-field issues associated with conventional imaging. The size and concentration of all particles, and each individual particle, can be rapidly and automatically assessed. The automated methods by which to extract these quantities can be readily evaluated using manual measurements. These methods are not possible using instruments based on optical and acoustic (back- or forward-) scattering, so-called 'sediment surrogate' methods, which are sensitive to the bulk quantities of all suspended particles in a sample volume, and rely on mathematically inverting a measured signal to derive the property of interest. Depending on the intended application, the number of holograms required to elucidate a process could range from tens to millions. Therefore manual particle extraction is not feasible for most data-sets. This has created a pressing need among the growing community of holography users, for accurate, automated processing which is comparable in output to more well-established in-situ sizing techniques such as laser diffraction. Here we discuss the computational considerations required to focus and segment individual particles from raw digital holograms, and then size and classify these particles by type; all using unsupervised (automated) image processing. To do so, we draw upon imagery from both controlled laboratory conditions to near-shore coastal environments, using different holographic system designs, and constituting a significant variety in particle types, sizes and shapes. We evaluate the success of these techniques, and suggest directions for future developments.
Automatic evidence retrieval for systematic reviews.
Choong, Miew Keen; Galgani, Filippo; Dunn, Adam G; Tsafnat, Guy
2014-10-01
Snowballing involves recursively pursuing relevant references cited in the retrieved literature and adding them to the search results. Snowballing is an alternative approach to discover additional evidence that was not retrieved through conventional search. Snowballing's effectiveness makes it best practice in systematic reviews despite being time-consuming and tedious. Our goal was to evaluate an automatic method for citation snowballing's capacity to identify and retrieve the full text and/or abstracts of cited articles. Using 20 review articles that contained 949 citations to journal or conference articles, we manually searched Microsoft Academic Search (MAS) and identified 78.0% (740/949) of the cited articles that were present in the database. We compared the performance of the automatic citation snowballing method against the results of this manual search, measuring precision, recall, and F1 score. The automatic method was able to correctly identify 633 (as proportion of included citations: recall=66.7%, F1 score=79.3%; as proportion of citations in MAS: recall=85.5%, F1 score=91.2%) of citations with high precision (97.7%), and retrieved the full text or abstract for 490 (recall=82.9%, precision=92.1%, F1 score=87.3%) of the 633 correctly retrieved citations. The proposed method for automatic citation snowballing is accurate and is capable of obtaining the full texts or abstracts for a substantial proportion of the scholarly citations in review articles. By automating the process of citation snowballing, it may be possible to reduce the time and effort of common evidence surveillance tasks such as keeping trial registries up to date and conducting systematic reviews.
Microseismic imaging using a source function independent full waveform inversion method
NASA Astrophysics Data System (ADS)
Wang, Hanchen; Alkhalifah, Tariq
2018-07-01
At the heart of microseismic event measurements is the task to estimate the location of the source microseismic events, as well as their ignition times. The accuracy of locating the sources is highly dependent on the velocity model. On the other hand, the conventional microseismic source locating methods require, in many cases, manual picking of traveltime arrivals, which do not only lead to manual effort and human interaction, but also prone to errors. Using full waveform inversion (FWI) to locate and image microseismic events allows for an automatic process (free of picking) that utilizes the full wavefield. However, FWI of microseismic events faces incredible nonlinearity due to the unknown source locations (space) and functions (time). We developed a source function independent FWI of microseismic events to invert for the source image, source function and the velocity model. It is based on convolving reference traces with these observed and modelled to mitigate the effect of an unknown source ignition time. The adjoint-state method is used to derive the gradient for the source image, source function and velocity updates. The extended image for the source wavelet in Z axis is extracted to check the accuracy of the inverted source image and velocity model. Also, angle gathers are calculated to assess the quality of the long wavelength component of the velocity model. By inverting for the source image, source wavelet and the velocity model simultaneously, the proposed method produces good estimates of the source location, ignition time and the background velocity for synthetic examples used here, like those corresponding to the Marmousi model and the SEG/EAGE overthrust model.
Somoskeöy, Szabolcs; Tunyogi-Csapó, Miklós; Bogyó, Csaba; Illés, Tamás
2012-10-01
For many decades, visualization and evaluation of three-dimensional (3D) spinal deformities have only been possible by two-dimensional (2D) radiodiagnostic methods, and as a result, characterization and classification were based on 2D terminologies. Recent developments in medical digital imaging and 3D visualization techniques including surface 3D reconstructions opened a chance for a long-sought change in this field. Supported by a 3D Terminology on Spinal Deformities of the Scoliosis Research Society, an approach for 3D measurements and a new 3D classification of scoliosis yielded several compelling concepts on 3D visualization and new proposals for 3D classification in recent years. More recently, a new proposal for visualization and complete 3D evaluation of the spine by 3D vertebra vectors has been introduced by our workgroup, a concept, based on EOS 2D/3D, a groundbreaking new ultralow radiation dose integrated orthopedic imaging device with sterEOS 3D spine reconstruction software. Comparison of accuracy, correlation of measurement values, intraobserver and interrater reliability of methods by conventional manual 2D and vertebra vector-based 3D measurements in a routine clinical setting. Retrospective, nonrandomized study of diagnostic X-ray images created as part of a routine clinical protocol of eligible patients examined at our clinic during a 30-month period between July 2007 and December 2009. In total, 201 individuals (170 females, 31 males; mean age, 19.88 years) including 10 healthy athletes with normal spine and patients with adolescent idiopathic scoliosis (175 cases), adult degenerative scoliosis (11 cases), and Scheuermann hyperkyphosis (5 cases). Overall range of coronal curves was between 2.4 and 117.5°. Analysis of accuracy and reliability of measurements was carried out on a group of all patients and in subgroups based on coronal plane deviation: 0 to 10° (Group 1; n=36), 10 to 25° (Group 2; n=25), 25 to 50° (Group 3; n=69), 50 to 75° (Group 4; n=49), and above 75° (Group 5; n=22). All study subjects were examined by EOS 2D imaging, resulting in anteroposterior (AP) and lateral (LAT) full spine, orthogonal digital X-ray images, in standing position. Conventional coronal and sagittal curvature measurements including sagittal L5 vertebra wedges were determined by 3 experienced examiners, using traditional Cobb methods on EOS 2D AP and LAT images. Vertebra vector-based measurements were performed as published earlier, based on computer-assisted calculations of corresponding spinal curvature. Vertebra vectors were generated by dedicated software from sterEOS 3D spine models reconstructed from EOS 2D images by the same three examiners. Manual measurements were performed by each examiner, thrice for sterEOS 3D reconstructions and twice for vertebra vector-based measurements. Means comparison t test, Pearson bivariate correlation analysis, reliability analysis by intraclass correlation coefficients for intraobserver reproducibility and interrater reliability were performed using SPSS v16.0 software. In comparison with manual 2D methods, only small and nonsignificant differences were detectable in vertebra vector-based curvature data for coronal curves and thoracic kyphosis, whereas the found difference in L1-L5 lordosis values was shown to be strongly related to the magnitude of corresponding L5 wedge. Intraobserver reliability was excellent for both methods, and interrater reproducibility was consistently higher for vertebra vector-based methods that was also found to be unaffected by the magnitude of coronal curves or sagittal plane deviations. Vertebra vector-based angulation measurements could fully substitute conventional manual 2D measurements, with similar accuracy and higher intraobserver reliability and interrater reproducibility. Vertebra vectors represent a truly 3D solution for clear and comprehensible 3D visualization of spinal deformities while preserving crucial parametric information for vertebral size, 3D position, orientation, and rotation. The concept of vertebra vectors may serve as a starting point to a valid and clinically useful alternative for a new 3D classification of scoliosis. Copyright © 2012 Elsevier Inc. All rights reserved.
Comparative study between manual injection intraosseous anesthesia and conventional oral anesthesia
Ata-Ali, Javier; Oltra-Moscardó, María J.; Peñarrocha-Diago, María; Peñarrocha, Miguel
2012-01-01
Objective: To compare intraosseous anesthesia (IA) with the conventional oral anesthesia techniques. Materials and methods: A simple-blind, prospective clinical study was carried out. Each patient underwent two anesthetic techniques: conventional (local infiltration and locoregional anesthetic block) and intraosseous, for res-pective dental operations. In order to allow comparison of IA versus conventional anesthesia, the two operations were similar and affected the same two teeth in opposite quadrants. Results: A total of 200 oral anesthetic procedures were carried out in 100 patients. The mean patient age was 28.6±9.92 years. Fifty-five vestibular infiltrations and 45 mandibular blocks were performed. All patients were also subjected to IA. The type of intervention (conservative or endodontic) exerted no significant influence (p=0.58 and p=0.62, respectively). The latency period was 8.52±2.44 minutes for the conventional techniques and 0.89±0.73 minutes for IA – the difference being statistically significant (p<0.05). Regarding patient anesthesia sensation, the infiltrative techniques lasted a maximum of one hour, the inferior alveolar nerve blocks lasted between 1-3 hours, and IA lasted only 2.5 minutes – the differences being statistically significant (p≤0.0000, Φ=0.29). Anesthetic success was recorded in 89% of the conventional procedures and in 78% of the IA. Most patients preferred IA (61%) (p=0.0032). Conclusions: The two anesthetic procedures have been compared for latency, duration of anesthetic effect, anesthetic success rate and patient preference. Intraosseous anesthesia has been shown to be a technique to be taken into account when planning conservative and endodontic treatments. Key words: Anesthesia, intraosseous, oral anesthesia, Stabident®, infiltrative, mandibular block. PMID:22143700
DOT National Transportation Integrated Search
1971-01-01
This manual describes a new method developed by the author, based on ASTM Method D2901, for determining the cement content of freshly mixed soil cement. The manual contains information on apparatus, reagents, procedures, source of equipment and reage...
A Manual of Simplified Laboratory Methods for Operators of Wastewater Treatment Facilities.
ERIC Educational Resources Information Center
Westerhold, Arnold F., Ed.; Bennett, Ernest C., Ed.
This manual is designed to provide the small wastewater treatment plant operator, as well as the new or inexperienced operator, with simplified methods for laboratory analysis of water and wastewater. It is emphasized that this manual is not a replacement for standard methods but a guide for plants with insufficient equipment to perform analyses…
Chang, Wen-Yu; Huang, Adam; Chen, Yin-Chun; Lin, Chi-Wei; Tsai, John; Yang, Chung-Kai; Huang, Yin-Tseng; Wu, Yi-Fan; Chen, Gwo-Shing
2015-05-03
To investigate the feasibility of manual segmentation by users of different backgrounds in a previously developed multifeature computer-aided diagnosis (CADx) system to classify melanocytic and non-melanocytic skin lesions based on conventional digital photographic images. In total, 347 conventional photographs of melanocytic and non-melanocytic skin lesions were retrospectively reviewed, and manually segmented by two groups of physicians, dermatologists and general practitioners, as well as by an automated segmentation software program, JSEG. The performance of CADx based on inputs from these two groups of physicians and that of the JSEG program was compared using feature agreement analysis. The estimated area under the receiver operating characteristic curve for classification of benign or malignant skin lesions based were comparable on individual segmentation by the gold standard (0.893, 95% CI 0.856 to 0.930), dermatologists (0.886, 95% CI 0.863 to 0.908), general practitioners (0.883, 95% CI 0.864 to 0.903) and JSEG (0.856, 95% CI 0.812 to 0.899). The agreement in the malignancy probability scores among the physicians was excellent (intraclass correlation coefficient: 0.91). By selecting an optimal cut-off value of malignancy probability score, the sensitivity and specificity were 80.07% and 81.47% for dermatologists and 79.90% and 80.20% for general practitioners. This study suggests that manual segmentation by general practitioners is feasible in the described CADx system for classifying benign and malignant skin lesions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Integration of autopatching with automated pipette and cell detection in vitro
Wu (吴秋雨), Qiuyu; Kolb, Ilya; Callahan, Brendan M.; Su, Zhaolun; Stoy, William; Kodandaramaiah, Suhasa B.; Neve, Rachael; Zeng, Hongkui; Boyden, Edward S.; Forest, Craig R.
2016-01-01
Patch clamp is the main technique for measuring electrical properties of individual cells. Since its discovery in 1976 by Neher and Sakmann, patch clamp has been instrumental in broadening our understanding of the fundamental properties of ion channels and synapses in neurons. The conventional patch-clamp method requires manual, precise positioning of a glass micropipette against the cell membrane of a visually identified target neuron. Subsequently, a tight “gigaseal” connection between the pipette and the cell membrane is established, and suction is applied to establish the whole cell patch configuration to perform electrophysiological recordings. This procedure is repeated manually for each individual cell, making it labor intensive and time consuming. In this article we describe the development of a new automatic patch-clamp system for brain slices, which integrates all steps of the patch-clamp process: image acquisition through a microscope, computer vision-based identification of a patch pipette and fluorescently labeled neurons, micromanipulator control, and automated patching. We validated our system in brain slices from wild-type and transgenic mice expressing channelrhodopsin 2 under the Thy1 promoter (line 18) or injected with a herpes simplex virus-expressing archaerhodopsin, ArchT. Our computer vision-based algorithm makes the fluorescent cell detection and targeting user independent. Compared with manual patching, our system is superior in both success rate and average trial duration. It provides more reliable trial-to-trial control of the patching process and improves reproducibility of experiments. PMID:27385800
van Wyk, A. C.; Marais, B. J.; Warren, R. M.; van Wyk, S. S.; Wright, C. A.
2011-01-01
SUMMARY BACKGROUND Fine-needle aspiration biopsy (FNAB) is a simple, safe and effective method for investigating suspected mycobacterial lymphadenitis in children. Fluorescence microscopy can provide rapid mycobacterial confirmation. Light-emitting diodes (LEDs) provide a cheap and robust excitation light source, making fluorescence microscopy feasible in resource-limited settings. OBJECTIVE To compare the diagnostic performance of LED fluorescence microscopy on Papanicolaou (PAP) stained smears with the conventional mercury vapour lamp (MVL). METHODS FNAB smears routinely collected from palpable lymph nodes in children with suspected mycobacterial disease were PAP-stained and evaluated by two independent microscopists using different excitatory light sources (MVL and LED). Mycobacterial culture results provided the reference standard. A manually rechargeable battery-powered LED power source was evaluated in a random subset. RESULTS We evaluated 182 FNAB smears from 121 children (median age 31 months, interquartile range 10–67). Mycobacterial cultures were positive in 84 of 121 (69%) children. The mean sensitivity with LED (mains-powered), LED (rechargeable battery-powered) and MVL was respectively 48.2%, 50.0% and 51.8% (specificity 78.4%, 86.7% and 78.4%). Inter-observer variation was similar for LED and MVL (κ = 0.5). CONCLUSION LED fluorescence microscopy provides a reliable alternative to conventional methods and has many favourable attributes that would facilitate improved, decentralised diagnostic services. PMID:21276297
Lozano López, C; Mesa Jiménez, J; de la Hoz Aizpurúa, J L; Pareja Grande, J; Fernández de Las Peñas, C
2016-01-01
To study the efficacy of manual therapy in the treatment of tension-type headache (TTH) by assessing the quality of randomized control trials (RCTs) published from the year 2000 to April 2013. A search was performed in the following databases: MEDLINE, EBSCO, CINAHL, SCOPUS, PEDRO and OVID. An analysis was made of RCT including patients with TTH receiving any manual therapy, and assessing outcome measures including the intensity, and frequency or duration of the headache. Two independent referees reviewed the methodological quality of RCTs using the Jadad scale. Data from the studies were extracted by two different reviewers. A total of fourteen RCTs were selected. Twelve studies showed acceptable quality (Jadad scale ≥3), and the remaining 2 had low quality (Jadad=2). The studies showed positive results, including reduction in headache intensity and/or frequency, reduction of medication consumption, and improvement in quality of life. The effectiveness of manual therapy for TTH cannot be completely assessed due to the heterogeneity in study design, outcome measures, and different treatments. Nevertheless, the results suggest patients with TTH receiving manual therapies showed better progress than those receiving conventional treatment or placebo. Further studies of high quality using manual therapy protocols, and also including standardized outcome measures, are now needed to clarify the efficacy of manual therapy in the management of TTH. Copyright © 2013 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heeswijk, Miriam M. van; Department of Surgery, Maastricht University Medical Centre, Maastricht; Lambregts, Doenja M.J., E-mail: d.lambregts@nki.nl
Purpose: Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Methods and Materials: Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained bymore » method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Results: Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the automated method, 41 to 69 seconds (pre-CRT) and 60 to 67 seconds (post-CRT) for the semiautomated method, and 180 to 296 seconds (pre-CRT) and 84 to 91 seconds (post-CRT) for the manual method. Conclusions: DWI volumetry using a semiautomated segmentation approach is promising and a potentially time-saving alternative to manual tumor delineation, particularly for primary tumor volumetry. Once further optimized, it could be a helpful tool for tumor response assessment in rectal cancer.« less
Bekmez, Senol; Demirkiran, Halil G; Yilmaz, Guney; Akel, Ibrahim; Atilla, Pergin; Muftuoglu, Sevda Fatma; Yazici, Muharrem; Alanay, Ahmet
2016-12-01
Experimental study. Convex growth arrest (CGA) has been commonly used in the treatment of long-sweeping congenital deformities of the immature spine. As there are major drawbacks about the anterior procedure in the conventional CGA method, a new modification has been documented that using only posterior spinal approach with pedicle screw instrumentation. The aim of the study was to compare posterior-only CGA using pedicle screws with combined anterior/posterior in-situ CGA for the findings in histologic, radiologic, and manual palpation examinations in an immature pig model. Twelve 10-weeks old pigs were grouped into 2. In group 1, posterior-only, pedicle screw instrumented CGA was performed on the left side of L1-L4 vertebrae. In group 2, conventional combined posterior and anterior CGA was performed to the left side of L1-L4 vertebrae without instrumentation. All animals were killed twelve weeks after surgery. T11-L5 segments were en-bloc resected and radiologic, histologic, and manual palpation examinations were done. Marked scoliotic (12.2±2.5 and 9.2±1.3 in group 1 and 2, respectively) and kyphotic (11.2±1.0 degrees for the group 1 and 12±5.2 degrees for the group 2, respectively) deformities were noted in both groups, which were caused by hemiepiphysiodesis effect. Anterior and posterior parts of group 2 and posterior part of group 1 demonstrated fusion in histologic and radiologic analyzes. In anterior part of the group 1, marked narrowing on the disk spaces and thinning of growth plates were noted in radiologicg examination, chondrocyte degeneration, and newly-formed bone trabeculae in disk-space were noted in histological examination. In manual palpation, no motion was detected in group 1 and motion was detected in only one segment of one animal in group 2. Anterior growth of the vertebrae can be controlled by application of posterior transpedicular screws and rod. Such an effect can eliminate the need for anterior surgical intervention in convex hemiepiphysiodesis procedures. The instrumented CGA technique provides a satisfactory epiphysiodesis effect both anteriorly and posteriorly, as previously demonstrated by clinical studies.
van Stralen, Marijn; Bosch, Johan G; Voormolen, Marco M; van Burken, Gerard; Krenning, Boudewijn J; van Geuns, Robert-Jan M; Lancée, Charles T; de Jong, Nico; Reiber, Johan H C
2005-10-01
We propose a semiautomatic endocardial border detection method for three-dimensional (3D) time series of cardiac ultrasound (US) data based on pattern matching and dynamic programming, operating on two-dimensional (2D) slices of the 3D plus time data, for the estimation of full cycle left ventricular volume, with minimal user interaction. The presented method is generally applicable to 3D US data and evaluated on data acquired with the Fast Rotating Ultrasound (FRU-) Transducer, developed by Erasmus Medical Center (Rotterdam, the Netherlands), a conventional phased-array transducer, rotating at very high speed around its image axis. The detection is based on endocardial edge pattern matching using dynamic programming, which is constrained by a 3D plus time shape model. It is applied to an automatically selected subset of 2D images of the original data set, for typically 10 equidistant rotation angles and 16 cardiac phases (160 images). Initialization requires the drawing of four contours per patient manually. We evaluated this method on 14 patients against MRI end-diastole and end-systole volumes. Initialization requires the drawing of four contours per patient manually. We evaluated this method on 14 patients against MRI end-diastolic (ED) and end-systolic (ES) volumes. The semiautomatic border detection approach shows good correlations with MRI ED/ES volumes (r = 0.938) and low interobserver variability (y = 1.005x - 16.7, r = 0.943) over full-cycle volume estimations. It shows a high consistency in tracking the user-defined initial borders over space and time. We show that the ease of the acquisition using the FRU-transducer and the semiautomatic endocardial border detection method together can provide a way to quickly estimate the left ventricular volume over the full cardiac cycle using little user interaction.
A self-adapting system for the automated detection of inter-ictal epileptiform discharges.
Lodder, Shaun S; van Putten, Michel J A M
2014-01-01
Scalp EEG remains the standard clinical procedure for the diagnosis of epilepsy. Manual detection of inter-ictal epileptiform discharges (IEDs) is slow and cumbersome, and few automated methods are used to assist in practice. This is mostly due to low sensitivities, high false positive rates, or a lack of trust in the automated method. In this study we aim to find a solution that will make computer assisted detection more efficient than conventional methods, while preserving the detection certainty of a manual search. Our solution consists of two phases. First, a detection phase finds all events similar to epileptiform activity by using a large database of template waveforms. Individual template detections are combined to form "IED nominations", each with a corresponding certainty value based on the reliability of their contributing templates. The second phase uses the ten nominations with highest certainty and presents them to the reviewer one by one for confirmation. Confirmations are used to update certainty values of the remaining nominations, and another iteration is performed where ten nominations with the highest certainty are presented. This continues until the reviewer is satisfied with what has been seen. Reviewer feedback is also used to update template accuracies globally and improve future detections. Using the described method and fifteen evaluation EEGs (241 IEDs), one third of all inter-ictal events were shown after one iteration, half after two iterations, and 74%, 90%, and 95% after 5, 10 and 15 iterations respectively. Reviewing fifteen iterations for the 20-30 min recordings 1 took approximately 5 min. The proposed method shows a practical approach for combining automated detection with visual searching for inter-ictal epileptiform activity. Further evaluation is needed to verify its clinical feasibility and measure the added value it presents.
Automatic Evidence Retrieval for Systematic Reviews
Choong, Miew Keen; Galgani, Filippo; Dunn, Adam G
2014-01-01
Background Snowballing involves recursively pursuing relevant references cited in the retrieved literature and adding them to the search results. Snowballing is an alternative approach to discover additional evidence that was not retrieved through conventional search. Snowballing’s effectiveness makes it best practice in systematic reviews despite being time-consuming and tedious. Objective Our goal was to evaluate an automatic method for citation snowballing’s capacity to identify and retrieve the full text and/or abstracts of cited articles. Methods Using 20 review articles that contained 949 citations to journal or conference articles, we manually searched Microsoft Academic Search (MAS) and identified 78.0% (740/949) of the cited articles that were present in the database. We compared the performance of the automatic citation snowballing method against the results of this manual search, measuring precision, recall, and F1 score. Results The automatic method was able to correctly identify 633 (as proportion of included citations: recall=66.7%, F1 score=79.3%; as proportion of citations in MAS: recall=85.5%, F1 score=91.2%) of citations with high precision (97.7%), and retrieved the full text or abstract for 490 (recall=82.9%, precision=92.1%, F1 score=87.3%) of the 633 correctly retrieved citations. Conclusions The proposed method for automatic citation snowballing is accurate and is capable of obtaining the full texts or abstracts for a substantial proportion of the scholarly citations in review articles. By automating the process of citation snowballing, it may be possible to reduce the time and effort of common evidence surveillance tasks such as keeping trial registries up to date and conducting systematic reviews. PMID:25274020
Zhang, Guodong; Brown, Eric W.; González-Escalona, Narjol
2011-01-01
Contamination of foods, especially produce, with Salmonella spp. is a major concern for public health. Several methods are available for the detection of Salmonella in produce, but their relative efficiency for detecting Salmonella in commonly consumed vegetables, often associated with outbreaks of food poisoning, needs to be confirmed. In this study, the effectiveness of three molecular methods for detection of Salmonella in six produce matrices was evaluated and compared to the FDA microbiological detection method. Samples of cilantro (coriander leaves), lettuce, parsley, spinach, tomato, and jalapeno pepper were inoculated with Salmonella serovars at two different levels (105 and <101 CFU/25 g of produce). The inoculated produce was assayed by the FDA Salmonella culture method (Bacteriological Analytical Manual) and by three molecular methods: quantitative real-time PCR (qPCR), quantitative reverse transcriptase real-time PCR (RT-qPCR), and loop-mediated isothermal amplification (LAMP). Comparable results were obtained by these four methods, which all detected as little as 2 CFU of Salmonella cells/25 g of produce. All control samples (not inoculated) were negative by the four methods. RT-qPCR detects only live Salmonella cells, obviating the danger of false-positive results from nonviable cells. False negatives (inhibition of either qPCR or RT-qPCR) were avoided by the use of either a DNA or an RNA amplification internal control (IAC). Compared to the conventional culture method, the qPCR, RT-qPCR, and LAMP assays allowed faster and equally accurate detection of Salmonella spp. in six high-risk produce commodities. PMID:21803916
2010-11 NCAA[R] Division II Manual
ERIC Educational Resources Information Center
National Collegiate Athletic Association (NJ1), 2010
2010-01-01
This publication incorporates the final legislative actions of the 104th annual NCAA Convention, January 13-16, 2010. In addition, interpretations incorporated by the Legislative Review Subcommittee, noncontroversial amendments adopted by the Management Council, pursuant to Constitution 5.3.1.1.1, and modifications of wording adopted by the…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-05
... with DoD 4145.26-M, DoD Contractors' Safety Manual for Ammunition and Explosives, and minimize risk of mishaps; [cir] Identify the place of performance of all ammunition and explosives work; and [cir] Ensure... Conventional Arms, Ammunition, and Explosives. In addition, this information collection requires DoD...
USDA-ARS?s Scientific Manuscript database
As sample preparation and analytical techniques have improved, data handling has become the main limitation in automated high-throughput analysis of targeted chemicals in many applications. Conventional chromatographic peak integration functions rely on complex software and settings, but untrustwor...
Tutorial on Generalized Programming Language s and Systems. Instructor Edition.
ERIC Educational Resources Information Center
Fasana, Paul J., Ed.; Shank, Russell, Ed.
This instructor's manual is a comparative analysis and review of the various computer programing languages currently available and their capabilities for performing text manipulation, information storage, and data retrieval tasks. Based on materials presented at the 1967 Convention of the American Society for Information Science, the manual…
A MANUAL OF JAPANESE WRITING, BOOK 1.
ERIC Educational Resources Information Center
CHAPLIN, HAMAKO ITO; MARTIN, SAMUEL E.
THIS IS THE FIRST OF THREE VOLUMES WRITTEN TO TEACH THE 881 ESSENTIAL OR "EDUCATION" CHARACTERS TO ENGLISH-SPEAKING STUDENTS OF JAPANESE. THE AUTHORS ASSUME THAT THE STUDENTS HAVE ALREADY LEARNED THE HIRAGANA AND KATAKANA SYLLABARIES AND HAVE A BASIC KNOWLEDGE OF JAPANESE GRAMMAR. ORTHOGRAPHIC CONVENTIONS USED FOLLOW CLOSELY THOSE…
NASA Astrophysics Data System (ADS)
Liang, Jiejunyi; Yang, Haitao; Wu, Jinglai; Zhang, Nong; Walker, Paul D.
2018-05-01
To improve the overall efficiency of electric vehicles and guarantee the driving comfort and vehicle drivability under the concept of simplifying mechanism complexity and minimizing manufacturing cost, this paper proposes a novel clutchless power-shifting transmission system with shifting control strategy and power sharing control strategy. The proposed shifting strategy takes advantage of the transmission architecture to achieve power-on shifting, which greatly improves the driving comfort compared with conventional automated manual transmission, with a bump function based shifting control method. To maximize the overall efficiency, a real-time power sharing control strategy is designed to solve the power distribution problem between the two motors. Detailed mathematical model is built to verify the effectiveness of the proposed methods. The results demonstrate the proposed strategies considerably improve the overall efficiency while achieve non-interrupted power-on shifting and maintain the vehicle jerk during shifting under an acceptable threshold.
Humidity compensation of bad-smell sensing system using a detector tube and a built-in camera
NASA Astrophysics Data System (ADS)
Hirano, Hiroyuki; Nakamoto, Takamichi
2011-09-01
We developed a low-cost sensing system robust against humidity change for detecting and estimating concentration of bad smell, such as hydrogen sulfide and ammonia. In the previous study, we developed automated measurement system for a gas detector tube using a built-in camera instead of the conventional manual inspection of the gas detector tube. Concentration detectable by the developed system ranges from a few tens of ppb to a few tens of ppm. However, we previously found that the estimated concentration depends not only on actual concentration, but on humidity. Here, we established the method to correct the influence of humidity by creating regression function with its inputs of discoloration rate and humidity. We studied 2 methods (Backpropagation, Radial basis function network) to get regression function and evaluated them. Consequently, the system successfully estimated the concentration on a practical level even when humidity changes.
Automated volumetric evaluation of stereoscopic disc photography
Xu, Juan; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A; Kagemann, Larry; Craig, Jamie E; Mackey, David A; Hewitt, Alex W; Schuman, Joel S
2010-01-01
PURPOSE: To develop a fully automated algorithm (AP) to perform a volumetric measure of the optic disc using conventional stereoscopic optic nerve head (ONH) photographs, and to compare algorithm-produced parameters with manual photogrammetry (MP), scanning laser ophthalmoscope (SLO) and optical coherence tomography (OCT) measurements. METHODS: One hundred twenty-two stereoscopic optic disc photographs (61 subjects) were analyzed. Disc area, rim area, cup area, cup/disc area ratio, vertical cup/disc ratio, rim volume and cup volume were automatically computed by the algorithm. Latent variable measurement error models were used to assess measurement reproducibility for the four techniques. RESULTS: AP had better reproducibility for disc area and cup volume and worse reproducibility for cup/disc area ratio and vertical cup/disc ratio, when the measurements were compared to the MP, SLO and OCT methods. CONCLUSION: AP provides a useful technique for an objective quantitative assessment of 3D ONH structures. PMID:20588996
Assessing Auditory Discrimination Skill of Malay Children Using Computer-based Method.
Ting, H; Yunus, J; Mohd Nordin, M Z
2005-01-01
The purpose of this paper is to investigate the auditory discrimination skill of Malay children using computer-based method. Currently, most of the auditory discrimination assessments are conducted manually by Speech-Language Pathologist. These conventional tests are actually general tests of sound discrimination, which do not reflect the client's specific speech sound errors. Thus, we propose computer-based Malay auditory discrimination test to automate the whole process of assessment as well as to customize the test according to the specific speech error sounds of the client. The ability in discriminating voiced and unvoiced Malay speech sounds was studied for the Malay children aged between 7 and 10 years old. The study showed no major difficulty for the children in discriminating the Malay speech sounds except differentiating /g/-/k/ sounds. Averagely the children of 7 years old failed to discriminate /g/-/k/ sounds.
Asphalt Raking. Instructor Manual. Trainee Manual.
ERIC Educational Resources Information Center
Laborers-AGC Education and Training Fund, Pomfret Center, CT.
This packet consists of the instructor and trainee manuals for an asphalt raking course. The instructor manual contains a course schedule for 4 days of instruction, content outline, and instructor outline. The trainee manual is divided into five sections: safety, asphalt basics, placing methods, repair and patching, and clean-up and maintenance.…
A comparison of manual and controlled-force attachment-level measurements.
Reddy, M S; Palcanis, K G; Geurs, N C
1997-12-01
This study compared the intra-examiner and inter-examiner error of 2 constant force probes to the reading of a conventional manual probe. 3 examiners made repeated examinations of attachment level using a modified Florida probe and a manual North Carolina probe (read to 1 mm or 0.5 mm); relative attachment level measurements were made using a Florida disk probe. One probe was used in each quadrant in 8 subjects with moderate to advanced periodontitis. Error was calculated as the mean of the absolute value of the difference between each examination, and the correlation between values at each examination calculated. Statistically-significant differences between probe type, examiners, and sites were detected using a repeated measures ANOVA accounting for the nesting within subjects. There was a significant difference in error by probe type (modified Florida probe 0.62 +/- 0.03 mm, r = 0.86; Florida stent probe 0.55 +/- 0.05 mm, r = 0.82; manual probe to 1 mm 0.39 +/- 0.02 mm, r = 0.88; manual probe to 0.5 mm 0.40 +/- 0.02 mm, r = 0.89; (p < 0.001). Significant differences were observed by examiners (p < 0.01). These data indicate that both manual and controlled-force probes can provide measurement within less than 1 mm of error; however, individual calibration of examiners remains important in the reduction of error.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Methods for Air Monitoring of Criteria Pollutants Pollutant Ref. or equivalent Manual or automated Applicable part 50 appendix Applicable subparts of part 53 A B C D E F SO2 Reference Manual A Equivalent Manual ✓ ✓ Automated ✓ ✓ ✓ CO Reference Automated C ✓ ✓ Equivalent Manual ✓ ✓ Automated ✓ ✓ ✓ O3...
Hao, Jie; Astle, William; De Iorio, Maria; Ebbels, Timothy M D
2012-08-01
Nuclear Magnetic Resonance (NMR) spectra are widely used in metabolomics to obtain metabolite profiles in complex biological mixtures. Common methods used to assign and estimate concentrations of metabolites involve either an expert manual peak fitting or extra pre-processing steps, such as peak alignment and binning. Peak fitting is very time consuming and is subject to human error. Conversely, alignment and binning can introduce artefacts and limit immediate biological interpretation of models. We present the Bayesian automated metabolite analyser for NMR spectra (BATMAN), an R package that deconvolutes peaks from one-dimensional NMR spectra, automatically assigns them to specific metabolites from a target list and obtains concentration estimates. The Bayesian model incorporates information on characteristic peak patterns of metabolites and is able to account for shifts in the position of peaks commonly seen in NMR spectra of biological samples. It applies a Markov chain Monte Carlo algorithm to sample from a joint posterior distribution of the model parameters and obtains concentration estimates with reduced error compared with conventional numerical integration and comparable to manual deconvolution by experienced spectroscopists. http://www1.imperial.ac.uk/medicine/people/t.ebbels/ t.ebbels@imperial.ac.uk.
Innovative Remote Sensors for Streamflow Measurement
NASA Astrophysics Data System (ADS)
Gourley, J. J.; Fulton, J. W.; Daniel, W.
2016-12-01
The United States Geological Survey operates and maintains over 7000 streamgages across the United States., Conventional streamgages have several important limitations: annual maintenance cost of approximately $15k makes gaging smaller basins uneconomical, manual updating of stage-discharge rating curves is inefficient and can be hazardous to operators, and instruments in contact with the water are sometimes damaged or lost during flood events. A suite of new, non-contact sensors is proposed to address these limitations and add new, previously unmeasured variables. First, a commercially available radar system has been fielded in a very dynamic stream environment and successfully used to measure stage height and stream velocity at high temporal resolution, on the order of a few minutes. Second, a custom water-penetrating lidar has been developed and demonstrated to map 1-D bathymetry (cross-section) in clear streams. Combined with stage and velocity measurements from the radar, this will allow for computation of discharge using non-contact methods without the need to update and maintain an empirical rating curve. Once mature, these technologies promise to reduce cost and manual intervention, allow proliferation of measurements to smaller streams, and introduce previously unmeasured variables to the hydrological scientist's toolbox.
You, Heecheon; Kumar, Anil; Young, Ronda; Veluswamy, Prabaharan; Malzahn, Don E
2005-09-01
The present study evaluated two design modifications (rubber grip and torsion spring) to the conventional manual Cleco pliers by electromyography (EMG), hand discomfort, and design satisfaction. This study also surveyed workers' satisfaction with selected design features of the pliers for ergonomic improvement. A two-way (plier design x worksurface angle) within-subject (nested within gender and hand size) design was employed. Eleven workers simulated the plier task in an adjustable workstation for different plier designs and worksurface angles (0 degrees , 60 degrees , and 90 degrees ). Lower EMG values were obtained for the pliers with rubber grip and at 60 degrees of worksurface angle. EMG values varied significantly between the participants, but showed low correlations (Spearman's rank correlation = -0.27 approximately -0.58) with their work experience with the pliers. The hand discomfort and design satisfaction evaluations identified that the grip span (max = 14.0 cm) and grip force requirement (peak = 220.5 N) of the current pliers need ergonomic modification. The present study shows the needs of both the ergonomic design of a hand tool and the training of a proper work method to control work-related musculoskeletal disorders at the workplace.
A Manual on Nonviolence and Children.
ERIC Educational Resources Information Center
Judson, Stephanie, Comp.
This manual on teaching children non-violent attitudes and the skills for non-violent conflict resolution suggests teaching activities and methods, describes classrooms in which these methods have been employed, and explains the underlying theory of conflict resolution. The first part of the manual, an outgrowth of the Friends' Nonviolence and…
NASA Technical Reports Server (NTRS)
Andrews, C. W.
1976-01-01
Volume fraction of a constituent or phase was estimated in six specimens of conventional and DS-eutectic superalloys, using ASTM E562-76, a new standard recommended practice for determining volume fraction by systematic manual point count. Volume fractions determined ranged from 0.086 to 0.36, and with one exception, the 95 percent relative confidence limits were approximately 10 percent of the determined volume fractions. Since the confidence-limit goal of 10 percent, which had been arbitrarily chosen previously, was achieved in all but one case, this application of the new practice was considered successful.
van Heeswijk, Miriam M; Lambregts, Doenja M J; van Griethuysen, Joost J M; Oei, Stanley; Rao, Sheng-Xiang; de Graaff, Carla A M; Vliegen, Roy F A; Beets, Geerard L; Papanikolaou, Nikos; Beets-Tan, Regina G H
2016-03-15
Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained by method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the automated method, 41 to 69 seconds (pre-CRT) and 60 to 67 seconds (post-CRT) for the semiautomated method, and 180 to 296 seconds (pre-CRT) and 84 to 91 seconds (post-CRT) for the manual method. DWI volumetry using a semiautomated segmentation approach is promising and a potentially time-saving alternative to manual tumor delineation, particularly for primary tumor volumetry. Once further optimized, it could be a helpful tool for tumor response assessment in rectal cancer. Copyright © 2016 Elsevier Inc. All rights reserved.
Burlina, Philippe; Billings, Seth; Joshi, Neil
2017-01-01
Objective To evaluate the use of ultrasound coupled with machine learning (ML) and deep learning (DL) techniques for automated or semi-automated classification of myositis. Methods Eighty subjects comprised of 19 with inclusion body myositis (IBM), 14 with polymyositis (PM), 14 with dermatomyositis (DM), and 33 normal (N) subjects were included in this study, where 3214 muscle ultrasound images of 7 muscles (observed bilaterally) were acquired. We considered three problems of classification including (A) normal vs. affected (DM, PM, IBM); (B) normal vs. IBM patients; and (C) IBM vs. other types of myositis (DM or PM). We studied the use of an automated DL method using deep convolutional neural networks (DL-DCNNs) for diagnostic classification and compared it with a semi-automated conventional ML method based on random forests (ML-RF) and “engineered” features. We used the known clinical diagnosis as the gold standard for evaluating performance of muscle classification. Results The performance of the DL-DCNN method resulted in accuracies ± standard deviation of 76.2% ± 3.1% for problem (A), 86.6% ± 2.4% for (B) and 74.8% ± 3.9% for (C), while the ML-RF method led to accuracies of 72.3% ± 3.3% for problem (A), 84.3% ± 2.3% for (B) and 68.9% ± 2.5% for (C). Conclusions This study demonstrates the application of machine learning methods for automatically or semi-automatically classifying inflammatory muscle disease using muscle ultrasound. Compared to the conventional random forest machine learning method used here, which has the drawback of requiring manual delineation of muscle/fat boundaries, DCNN-based classification by and large improved the accuracies in all classification problems while providing a fully automated approach to classification. PMID:28854220
NASA Astrophysics Data System (ADS)
Werner, Jochen A.; Gottschlich, Stefan; Lippert, Burkard M.; Folz, Benedikt J.
1998-01-01
Voluminous vascular anomalies of the head and neck region are still treated with conventional surgery although Neodymium:Yttrium-Aluminum-Garnet (Nd:YAG) laser therapy is an effective treatment method. One hundred thirty give patients with voluminous hemangiomas and vascular malformations were treated with interstitial Nd:YAG laser therapy, partly complemented by a non-contact mode Nd:YAG laser light application. The vascular tumors had a diameter of more than 3 cm in two or all three dimensions. Treatment was carried out under ultrasound and manual control. Nearly 60% of the patients showed a complete clinical regression of the vascular tumor, a third of the patients had a partial regression and were satisfied with the treatment outcome. Four patients were treated unsuccessfully with the laser and three of them subsequently underwent conventional surgery. Only 10 patients showed cosmetic and functional deficits. These results on the interstitial Nd:YAG laser therapy of voluminous hemangiomas and vascular malformations in a large patient group demonstrated the high effectiveness of this novel and innovative therapy modality.
Li, Zhixun; Zhang, Yingtao; Gong, Huiling; Li, Weimin; Tang, Xianglong
2016-12-01
Coronary artery disease has become the most dangerous diseases to human life. And coronary artery segmentation is the basis of computer aided diagnosis and analysis. Existing segmentation methods are difficult to handle the complex vascular texture due to the projective nature in conventional coronary angiography. Due to large amount of data and complex vascular shapes, any manual annotation has become increasingly unrealistic. A fully automatic segmentation method is necessary in clinic practice. In this work, we study a method based on reliable boundaries via multi-domains remapping and robust discrepancy correction via distance balance and quantile regression for automatic coronary artery segmentation of angiography images. The proposed method can not only segment overlapping vascular structures robustly, but also achieve good performance in low contrast regions. The effectiveness of our approach is demonstrated on a variety of coronary blood vessels compared with the existing methods. The overall segmentation performances si, fnvf, fvpf and tpvf were 95.135%, 3.733%, 6.113%, 96.268%, respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.
Storlazzi, Curt; Dartnell, Peter; Hatcher, Gerry; Gibbs, Ann E.
2016-01-01
The rugosity or complexity of the seafloor has been shown to be an important ecological parameter for fish, algae, and corals. Historically, rugosity has been measured either using simple and subjective manual methods such as ‘chain-and-tape’ or complicated and expensive geophysical methods. Here, we demonstrate the application of structure-from-motion (SfM) photogrammetry to generate high-resolution, three-dimensional bathymetric models of a fringing reef from existing underwater video collected to characterize the seafloor. SfM techniques are capable of achieving spatial resolution that can be orders of magnitude greater than large-scale lidar and sonar mapping of coral reef ecosystems. The resulting data provide finer-scale measurements of bathymetry and rugosity that are more applicable to ecological studies of coral reefs than provided by the more expensive and time-consuming geophysical methods. Utilizing SfM techniques for characterizing the benthic habitat proved to be more effective and quantitatively powerful than conventional methods and thus might portend the end of the ‘chain-and-tape’ method for measuring benthic complexity.
Enhanced anatomical calibration in human movement analysis.
Donati, Marco; Camomilla, Valentina; Vannozzi, Giuseppe; Cappozzo, Aurelio
2007-07-01
The representation of human movement requires knowledge of both movement and morphology of bony segments. The determination of subject-specific morphology data and their registration with movement data is accomplished through an anatomical calibration procedure (calibrated anatomical systems technique: CAST). This paper describes a novel approach to this calibration (UP-CAST) which, as compared with normally used techniques, achieves better repeatability, a shorter application time, and can be effectively performed by non-skilled examiners. Instead of the manual location of prominent bony anatomical landmarks, the description of which is affected by subjective interpretation, a large number of unlabelled points is acquired over prominent parts of the subject's bone, using a wand fitted with markers. A digital model of a template-bone is then submitted to isomorphic deformation and re-orientation to optimally match the above-mentioned points. The locations of anatomical landmarks are automatically made available. The UP-CAST was validated considering the femur as a paradigmatic case. Intra- and inter-examiner repeatability of the identification of anatomical landmarks was assessed both in vivo, using average weight subjects, and on bare bones. Accuracy of the identification was assessed using the anatomical landmark locations manually located on bare bones as reference. The repeatability of this method was markedly higher than that reported in the literature and obtained using the conventional palpation (ranges: 0.9-7.6 mm and 13.4-17.9, respectively). Accuracy resulted, on average, in a maximal error of 11 mm. Results suggest that the principal source of variability resides in the discrepancy between subject's and template bone morphology and not in the inter-examiner differences. The UP-CAST anatomical calibration could be considered a promising alternative to conventional calibration contributing to a more repeatable 3D human movement analysis.
The effect of e-learning on the quality of orthodontic appliances
Schorn-Borgmann, Stephanie; Lippold, Carsten; Wiechmann, Dirk; Stamm, Thomas
2015-01-01
Purpose The effect of e-learning on practical skills in medicine has not yet been thoroughly investigated. Today’s multimedia learning environment and access to e-books provide students with more knowledge than ever before. The aim of this study is to evaluate the effect of online demonstrations concerning the quality of orthodontic appliances manufactured by undergraduate dental students. Materials and methods The study design was a parallel-group randomized clinical trial. Fifty-four participants were randomly assigned to one of the three groups: 1) conventional lectures, 2) conventional lectures plus written online material, and 3) access to resources of groups one and two plus access to online video material. Three orthodontic appliances (Schwarz Plate, U-Bow Activator, and Fränkel Regulator) were manufactured during the course and scored by two independent raters blinded to the participants. A 15-point scale index was used to evaluate the outcome quality of the appliances. Results In general, no significant differences were found between the groups. Concerning the appliances, the Schwarz Plate obtained the highest scores, whereas the Fränkel Regulator had the lowest scores; however, these results were independent of the groups. Females showed better outcome scores than males in groups two and three, but the difference was insignificant. Age of the participants also had no significant effect. Conclusion The offer that students could use additional time and course-independent e-learning resources did not increase the outcome quality of the orthodontic appliances. The advantages of e-learning observed in the theoretical fields of medicine were not achieved in the educational procedures for manual skills. Factors other than e-learning may have a higher impact on manual skills, and this should be investigated in further studies. PMID:26346485
NASA Astrophysics Data System (ADS)
Zhu, Feng; Akagi, Jin; Hall, Chris J.; Crosier, Kathryn E.; Crosier, Philip S.; Delaage, Pierre; Wlodkowic, Donald
2013-12-01
Drug discovery screenings performed on zebrafish embryos mirror with a high level of accuracy. The tests usually performed on mammalian animal models, and the fish embryo toxicity assay (FET) is one of the most promising alternative approaches to acute ecotoxicity testing with adult fish. Notwithstanding this, conventional methods utilising 96-well microtiter plates and manual dispensing of fish embryos are very time-consuming. They rely on laborious and iterative manual pipetting that is a main source of analytical errors and low throughput. In this work, we present development of a miniaturised and high-throughput Lab-on-a-Chip (LOC) platform for automation of FET assays. The 3D high-density LOC array was fabricated in poly-methyl methacrylate (PMMA) transparent thermoplastic using infrared laser micromachining while the off-chip interfaces were fabricated using additive manufacturing processes (FDM and SLA). The system's design facilitates rapid loading and immobilization of a large number of embryos in predefined clusters of traps during continuous microperfusion of drugs/toxins. It has been conceptually designed to seamlessly interface with both upright and inverted fluorescent imaging systems and also to directly interface with conventional microtiter plate readers that accept 96-well plates. We also present proof-of-concept interfacing with a high-speed imaging cytometer Plate RUNNER HD® capable of multispectral image acquisition with resolution of up to 8192 x 8192 pixels and depth of field of about 40 μm. Furthermore, we developed a miniaturized and self-contained analytical device interfaced with a miniaturized USB microscope. This system modification is capable of performing rapid imaging of multiple embryos at a low resolution for drug toxicity analysis.
Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients
Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan
2016-01-01
Aim: The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. Material and Methods: The study was conducted at the Be’sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Results: Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Conclusion: Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable. PMID:27703289
Threshold-driven optimization for reference-based auto-planning
NASA Astrophysics Data System (ADS)
Long, Troy; Chen, Mingli; Jiang, Steve; Lu, Weiguo
2018-02-01
We study threshold-driven optimization methodology for automatically generating a treatment plan that is motivated by a reference DVH for IMRT treatment planning. We present a framework for threshold-driven optimization for reference-based auto-planning (TORA). Commonly used voxel-based quadratic penalties have two components for penalizing under- and over-dosing of voxels: a reference dose threshold and associated penalty weight. Conventional manual- and auto-planning using such a function involves iteratively updating the preference weights while keeping the thresholds constant, an unintuitive and often inconsistent method for planning toward some reference DVH. However, driving a dose distribution by threshold values instead of preference weights can achieve similar plans with less computational effort. The proposed methodology spatially assigns reference DVH information to threshold values, and iteratively improves the quality of that assignment. The methodology effectively handles both sub-optimal and infeasible DVHs. TORA was applied to a prostate case and a liver case as a proof-of-concept. Reference DVHs were generated using a conventional voxel-based objective, then altered to be either infeasible or easy-to-achieve. TORA was able to closely recreate reference DVHs in 5-15 iterations of solving a simple convex sub-problem. TORA has the potential to be effective for auto-planning based on reference DVHs. As dose prediction and knowledge-based planning becomes more prevalent in the clinical setting, incorporating such data into the treatment planning model in a clear, efficient way will be crucial for automated planning. A threshold-focused objective tuning should be explored over conventional methods of updating preference weights for DVH-guided treatment planning.
Burlina, Philippe; Billings, Seth; Joshi, Neil; Albayda, Jemima
2017-01-01
To evaluate the use of ultrasound coupled with machine learning (ML) and deep learning (DL) techniques for automated or semi-automated classification of myositis. Eighty subjects comprised of 19 with inclusion body myositis (IBM), 14 with polymyositis (PM), 14 with dermatomyositis (DM), and 33 normal (N) subjects were included in this study, where 3214 muscle ultrasound images of 7 muscles (observed bilaterally) were acquired. We considered three problems of classification including (A) normal vs. affected (DM, PM, IBM); (B) normal vs. IBM patients; and (C) IBM vs. other types of myositis (DM or PM). We studied the use of an automated DL method using deep convolutional neural networks (DL-DCNNs) for diagnostic classification and compared it with a semi-automated conventional ML method based on random forests (ML-RF) and "engineered" features. We used the known clinical diagnosis as the gold standard for evaluating performance of muscle classification. The performance of the DL-DCNN method resulted in accuracies ± standard deviation of 76.2% ± 3.1% for problem (A), 86.6% ± 2.4% for (B) and 74.8% ± 3.9% for (C), while the ML-RF method led to accuracies of 72.3% ± 3.3% for problem (A), 84.3% ± 2.3% for (B) and 68.9% ± 2.5% for (C). This study demonstrates the application of machine learning methods for automatically or semi-automatically classifying inflammatory muscle disease using muscle ultrasound. Compared to the conventional random forest machine learning method used here, which has the drawback of requiring manual delineation of muscle/fat boundaries, DCNN-based classification by and large improved the accuracies in all classification problems while providing a fully automated approach to classification.
Sex Stereotype Measure II and Sex Attitude Measure. General Information and Manual of Directions.
ERIC Educational Resources Information Center
Williams, John E.; And Others
The Sex Stereotype Measure (SSM II) measures children's knowledge of adult-defined, conventional, sex-trait stereotypes while the Sex Attitude Measure (SAM) measures children's attitudes or evaluative bias toward male and female persons, independent of their stereotype knowledge. Both procedures employ two or three sentence stories and human…
Yeki Bood/Yeki Na Bood: Writing and Publishing as a Teacher Researcher.
ERIC Educational Resources Information Center
Fecho, Bob
2003-01-01
Discusses considerations faced by practitioner researchers as they write for publication, particularly as they encounter the template of the Publication Manual of the American Psychological Association (APA). Argues that some APA conventions--such as beginning an article with theory rather than the story of the research--do not suite the purposes…
Operation of Wastewater Treatment Plants: A Field Study Training Program. Volume II. Second Edition.
ERIC Educational Resources Information Center
California State Univ., Sacramento. Dept. of Civil Engineering.
This manual was prepared by experienced wastewater collection system workers to provide a home study course to develop new qualified workers and expand the abilities of existing workers. This volume emphasizes material needed by intermediate-level operators and stresses the operation and maintenance of conventional treatment plants. This volume…
Operation of Wastewater Treatment Plants, Manual of Practice No. 11.
ERIC Educational Resources Information Center
Albertson, Orrie E.; And Others
This book is intended to be a reference or textbook on the operation of wastewater treatment plants. The book contains thirty-one chapters and three appendices and includes the description, requirements, and latest techniques of conventional unit process operation, as well as the symptoms and corrective measures regarding process problems. Process…
The Economic Consequences of Being Left-Handed: Some Sinister Results
ERIC Educational Resources Information Center
Denny, Kevin; O' Sullivan, Vincent
2007-01-01
This paper estimates the effects of handedness on earnings. Augmenting a conventional earnings equation with an indicator of left-handedness shows there is a positive effect on male earnings with manual workers enjoying a slightly larger premium. These results are inconsistent with the view that left-handers in general are handicapped either…
Readings in Computer Based Guidance. The Bartlesville System.
ERIC Educational Resources Information Center
Bartlesville Public Schools, OK.
The document contains six papers which deal with the need for change in guidance and counseling due to the overwhelming amount of data which is insufficiently processed by conventional manual systems. Included in these papers are discussions on when these changes should occur and the nature of their alterations. The reports consider some of the…
7 CFR 91.23 - Analytical methods.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 3 2014-01-01 2014-01-01 false Analytical methods. 91.23 Section 91.23 Agriculture... SERVICES AND GENERAL INFORMATION Method Manuals § 91.23 Analytical methods. Most analyses are performed according to approved procedures described in manuals of standardized methodology. These standard methods...
7 CFR 91.23 - Analytical methods.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Analytical methods. 91.23 Section 91.23 Agriculture... SERVICES AND GENERAL INFORMATION Method Manuals § 91.23 Analytical methods. Most analyses are performed according to approved procedures described in manuals of standardized methodology. These standard methods...
7 CFR 91.23 - Analytical methods.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 3 2013-01-01 2013-01-01 false Analytical methods. 91.23 Section 91.23 Agriculture... SERVICES AND GENERAL INFORMATION Method Manuals § 91.23 Analytical methods. Most analyses are performed according to approved procedures described in manuals of standardized methodology. These standard methods...
Field manual for the collection of Navajo Nation streamflow-gage data
Hart, Robert J.; Fisk, Gregory G.
2014-01-01
The Field Manual for the Collection of Navajo Nation Streamflow-Gage Data (Navajo Field Manual) is based on established (standard) U.S. Geological Survey streamflow-gaging methods and provides guidelines specifically designed for the Navajo Department of Water Resources personnel who establish and maintain streamflow gages. The Navajo Field Manual addresses field visits, including essential field equipment and the selection of and routine visits to streamflow-gaging stations, examines surveying methods for determining peak flows (indirect measurements), discusses safety considerations, and defines basic terms.
The effect of varying levels of vehicle automation on drivers' lane changing behaviour.
Madigan, Ruth; Louw, Tyron; Merat, Natasha
2018-01-01
Much of the Human Factors research into vehicle automation has focused on driver responses to critical scenarios where a crash might occur. However, there is less knowledge about the effects of vehicle automation on drivers' behaviour during non-critical take-over situations, such as driver-initiated lane-changing or overtaking. The current driving simulator study, conducted as part of the EC-funded AdaptIVe project, addresses this issue. It uses a within-subjects design to compare drivers' lane-changing behaviour in conventional manual driving, partially automated driving (PAD) and conditionally automated driving (CAD). In PAD, drivers were required to re-take control from an automated driving system in order to overtake a slow moving vehicle, while in CAD, the driver used the indicator lever to initiate a system-performed overtaking manoeuvre. Results showed that while drivers' acceptance of both the PAD and CAD systems was high, they generally preferred CAD. A comparison of overtaking positions showed that drivers initiated overtaking manoeuvres slightly later in PAD than in manual driving or CAD. In addition, when compared to conventional driving, drivers had higher deviations in lane positioning and speed, along with higher lateral accelerations during lane changes following PAD. These results indicate that even in situations which are not time-critical, drivers' vehicle control after automation is degraded compared to conventional driving.
The effect of varying levels of vehicle automation on drivers’ lane changing behaviour
Louw, Tyron; Merat, Natasha
2018-01-01
Much of the Human Factors research into vehicle automation has focused on driver responses to critical scenarios where a crash might occur. However, there is less knowledge about the effects of vehicle automation on drivers’ behaviour during non-critical take-over situations, such as driver-initiated lane-changing or overtaking. The current driving simulator study, conducted as part of the EC-funded AdaptIVe project, addresses this issue. It uses a within-subjects design to compare drivers’ lane-changing behaviour in conventional manual driving, partially automated driving (PAD) and conditionally automated driving (CAD). In PAD, drivers were required to re-take control from an automated driving system in order to overtake a slow moving vehicle, while in CAD, the driver used the indicator lever to initiate a system-performed overtaking manoeuvre. Results showed that while drivers’ acceptance of both the PAD and CAD systems was high, they generally preferred CAD. A comparison of overtaking positions showed that drivers initiated overtaking manoeuvres slightly later in PAD than in manual driving or CAD. In addition, when compared to conventional driving, drivers had higher deviations in lane positioning and speed, along with higher lateral accelerations during lane changes following PAD. These results indicate that even in situations which are not time-critical, drivers’ vehicle control after automation is degraded compared to conventional driving. PMID:29466402
Abdominal fat volume estimation by stereology on CT: a comparison with manual planimetry.
Manios, G E; Mazonakis, M; Voulgaris, C; Karantanas, A; Damilakis, J
2016-03-01
To deploy and evaluate a stereological point-counting technique on abdominal CT for the estimation of visceral (VAF) and subcutaneous abdominal fat (SAF) volumes. Stereological volume estimations based on point counting and systematic sampling were performed on images from 14 consecutive patients who had undergone abdominal CT. For the optimization of the method, five sampling intensities in combination with 100 and 200 points were tested. The optimum stereological measurements were compared with VAF and SAF volumes derived by the standard technique of manual planimetry on the same scans. Optimization analysis showed that the selection of 200 points along with the sampling intensity 1/8 provided efficient volume estimations in less than 4 min for VAF and SAF together. The optimized stereology showed strong correlation with planimetry (VAF: r = 0.98; SAF: r = 0.98). No statistical differences were found between the two methods (VAF: P = 0.81; SAF: P = 0.83). The 95% limits of agreement were also acceptable (VAF: -16.5%, 16.1%; SAF: -10.8%, 10.7%) and the repeatability of stereology was good (VAF: CV = 4.5%, SAF: CV = 3.2%). Stereology may be successfully applied to CT images for the efficient estimation of abdominal fat volume and may constitute a good alternative to the conventional planimetric technique. Abdominal obesity is associated with increased risk of disease and mortality. Stereology may quantify visceral and subcutaneous abdominal fat accurately and consistently. The application of stereology to estimating abdominal volume fat reduces processing time. Stereology is an efficient alternative method for estimating abdominal fat volume.
[Magnetic navigation for ablation of cardiac arrhythmias].
Chen, Jian; Hoff, Per Ivar; Solheim, Eivind; Schuster, Peter; Off, Morten Kristian; Ohm, Ole-Jørgen
2010-08-12
The first use of magnetic navigation for radiofrequency ablation of supraventricular tachycardias, was published in 2004. Subsequently, the method has been used for treatment of most types of tachyarrhythmias. This paper provides an overview of the method, with special emphasis on usefulness of a new remote-controlled magnetic navigation system. The paper is based on our own scientific experience and literature identified through a non-systematic search in PubMed. The magnetic navigation system consists of two external electromagnets (to be placed on opposite sides of the patient), which guide an ablation catheter (with a small magnet at the tip of the catheter) to the target area in the heart. The accuracy of this procedure is higher than that with manual navigation. Personnel can be quickly trained to use remote magnetic navigation, but the procedure itself is time-consuming, particularly for patients with atrial fibrillation. The major advantage is a considerably lower radiation burden to both patient and operator, in some studies more than 50 %, and a corresponding reduction in physical strain on the operator. The incidence of procedure-related complications seems to be lower than that observed with use of manually operated ablation catheters. Work is ongoing to improve magnetic ablation catheters and methods that can simplify mapping procedures and improve efficacy of arrhythmia ablation. The basic cost for installing a complete magnetic navigation laboratory may be three times that of a conventional electrophysiological laboratory. The new magnetic navigation system has proved to be applicable during ablation for a variety of tachyarrhythmias, but is still under development.
Junger, Axel; Brenck, Florian; Hartmann, Bernd; Klasen, Joachim; Quinzio, Lorenzo; Benson, Matthias; Michel, Achim; Röhrig, Rainer; Hempelmann, Gunter
2004-07-01
The most recent approach to estimate nursing resources consumption has led to the generation of the Nine Equivalents of Nursing Manpower use Score (NEMS). The objective of this prospective study was to establish a completely automatically generated calculation of the NEMS using a patient data management system (PDMS) database and to validate this approach by comparing the results with those of the conventional manual method. Prospective study. Operative intensive care unit of a university hospital. Patients admitted to the ICU between 24 July 2002 and 22 August 2002. Patients under the age of 16 years, and patients undergoing cardiovascular surgery or with burn injuries were excluded. None. The NEMS of all patients was calculated automatically with a PDMS and manually by a physician in parallel. The results of the two methods were compared using the Bland and Altman approach, the interclass correlation coefficient (ICC), and the kappa-statistic. On 20 consecutive working days, the NEMS was calculated in 204 cases. The Bland Altman analysis did not show significant differences in NEMS scoring between the two methods. The ICC (95% confidence intervals) 0.87 (0.84-0.90) revealed a high inter-rater agreement between the PDMS and the physician. The kappa-statistic showed good results (kappa>0.55) for all NEMS items apart from the item "supplementary ventilatory care". This study demonstrates that automatical calculation of the NEMS is possible with high accuracy by means of a PDMS. This may lead to a decrease in consumption of nursing resources.
Burgess, Alexandra J.; Retkute, Renata; Pound, Michael P.; Foulkes, John; Preston, Simon P.; Jensen, Oliver E.; Pridmore, Tony P.; Murchie, Erik H.
2015-01-01
Photoinhibition reduces photosynthetic productivity; however, it is difficult to quantify accurately in complex canopies partly because of a lack of high-resolution structural data on plant canopy architecture, which determines complex fluctuations of light in space and time. Here, we evaluate the effects of photoinhibition on long-term carbon gain (over 1 d) in three different wheat (Triticum aestivum) lines, which are architecturally diverse. We use a unique method for accurate digital three-dimensional reconstruction of canopies growing in the field. The reconstruction method captures unique architectural differences between lines, such as leaf angle, curvature, and leaf density, thus providing a sensitive method of evaluating the productivity of actual canopy structures that previously were difficult or impossible to obtain. We show that complex data on light distribution can be automatically obtained without conventional manual measurements. We use a mathematical model of photosynthesis parameterized by field data consisting of chlorophyll fluorescence, light response curves of carbon dioxide assimilation, and manual confirmation of canopy architecture and light attenuation. Model simulations show that photoinhibition alone can result in substantial reduction in carbon gain, but this is highly dependent on exact canopy architecture and the diurnal dynamics of photoinhibition. The use of such highly realistic canopy reconstructions also allows us to conclude that even a moderate change in leaf angle in upper layers of the wheat canopy led to a large increase in the number of leaves in a severely light-limited state. PMID:26282240
Micro-seismic imaging using a source function independent full waveform inversion method
NASA Astrophysics Data System (ADS)
Wang, Hanchen; Alkhalifah, Tariq
2018-03-01
At the heart of micro-seismic event measurements is the task to estimate the location of the source micro-seismic events, as well as their ignition times. The accuracy of locating the sources is highly dependent on the velocity model. On the other hand, the conventional micro-seismic source locating methods require, in many cases manual picking of traveltime arrivals, which do not only lead to manual effort and human interaction, but also prone to errors. Using full waveform inversion (FWI) to locate and image micro-seismic events allows for an automatic process (free of picking) that utilizes the full wavefield. However, full waveform inversion of micro-seismic events faces incredible nonlinearity due to the unknown source locations (space) and functions (time). We developed a source function independent full waveform inversion of micro-seismic events to invert for the source image, source function and the velocity model. It is based on convolving reference traces with these observed and modeled to mitigate the effect of an unknown source ignition time. The adjoint-state method is used to derive the gradient for the source image, source function and velocity updates. The extended image for the source wavelet in Z axis is extracted to check the accuracy of the inverted source image and velocity model. Also, angle gathers is calculated to assess the quality of the long wavelength component of the velocity model. By inverting for the source image, source wavelet and the velocity model simultaneously, the proposed method produces good estimates of the source location, ignition time and the background velocity for synthetic examples used here, like those corresponding to the Marmousi model and the SEG/EAGE overthrust model.
Mitchell, Andrea Z; McMahon, Carrie; Beck, Tom W; Sarazan, R Dustan
2010-01-01
Animals are commonly used in toxicological research for the evaluation of drug effects on the cardiovascular system. Accurate and reproducible determination of blood pressure (BP) in conscious, manually restrained monkeys and dogs is a challenge with current non-invasive cuff techniques. The High Definition Oscillometry (HDO) technique enables real time measurements with immediate visual feedback via PC screen on data validity. HDO measurements are considerably faster with a duration of approximately 8 to 15s than conventional cuff methods that can take several minutes. HDO Memo Diagnostic Model Science and Cardell BP Monitor Model 9401 measurements were compared for accuracy and reliability with simultaneously recorded direct blood pressure data captured via radiotelemetry. Six monkeys and six dogs implanted with DSI PCT telemetry transmitters were used; BP data were collected by all methods under manual constraint and compared. Measurements were performed with HDO and Cardell in the presence of a BP lowering drug (hexamethonium bromide). Systolic, diastolic, mean arterial pressure, and pulse rate were determined before, during and following up to 10mg/kg hexamethonium administration via intravenous slow bolus injection. Drug induced hemodynamic changes could be detected in monkeys and dogs with the HDO method but only in dogs with the Cardell method. Correlation coefficients were generally higher for HDO versus Telemetry than Cardell versus Telemetry comparisons, indicating that this novel, non-invasive technique produces reliable blood pressure data and is able to detect drug-induced hemodynamic changes. HDO provides an alternative approach for invasive telemetry surgeries to obtain reliable hemodynamic data in animal models for cardiovascular research when invasive techniques are not warranted. Copyright 2010 Elsevier Inc. All rights reserved.
Resource Manual: Handicapped Children Birth to Five. Part 2.
ERIC Educational Resources Information Center
Leslie, Lin; And Others
The resource manual, in two parts, provides a compilation of methods for enhancing the development of handicapped children from birth to 5 years in the areas of motor, communication, cognition, self help, and social skills. The manual is intended to aid in (1) assessing and identifying target behaviors to be achieved, (2) identifying methods for…
NASA Technical Reports Server (NTRS)
Hartle, M.; McKnight, R. L.
2000-01-01
This manual is a combination of a user manual, theory manual, and programmer manual. The reader is assumed to have some previous exposure to the finite element method. This manual is written with the idea that the CSTEM (Coupled Structural Thermal Electromagnetic-Computer Code) user needs to have a basic understanding of what the code is actually doing in order to properly use the code. For that reason, the underlying theory and methods used in the code are described to a basic level of detail. The manual gives an overview of the CSTEM code: how the code came into existence, a basic description of what the code does, and the order in which it happens (a flowchart). Appendices provide a listing and very brief description of every file used by the CSTEM code, including the type of file it is, what routine regularly accesses the file, and what routine opens the file, as well as special features included in CSTEM.
Wigg, Jonathan P.; Zhang, Hong; Yang, Dong
2015-01-01
Introduction In-vivo imaging of choroidal neovascularization (CNV) has been increasingly recognized as a valuable tool in the investigation of age-related macular degeneration (AMD) in both clinical and basic research applications. Arguably the most widely utilised model replicating AMD is laser generated CNV by rupture of Bruch’s membrane in rodents. Heretofore CNV evaluation via in-vivo imaging techniques has been hamstrung by a lack of appropriate rodent fundus camera and a non-standardised analysis method. The aim of this study was to establish a simple, quantifiable method of fluorescein fundus angiogram (FFA) image analysis for CNV lesions. Methods Laser was applied to 32 Brown Norway Rats; FFA images were taken using a rodent specific fundus camera (Micron III, Phoenix Laboratories) over 3 weeks and compared to conventional ex-vivo CNV assessment. FFA images acquired with fluorescein administered by intraperitoneal injection and intravenous injection were compared and shown to greatly influence lesion properties. Utilising commonly used software packages, FFA images were assessed for CNV and chorioretinal burns lesion area by manually outlining the maximum border of each lesion and normalising against the optic nerve head. Net fluorescence above background and derived value of area corrected lesion intensity were calculated. Results CNV lesions of rats treated with anti-VEGF antibody were significantly smaller in normalised lesion area (p<0.001) and fluorescent intensity (p<0.001) than the PBS treated control two weeks post laser. The calculated area corrected lesion intensity was significantly smaller (p<0.001) in anti-VEGF treated animals at 2 and 3 weeks post laser. The results obtained using FFA correlated with, and were confirmed by conventional lesion area measurements from isolectin stained choroidal flatmounts, where lesions of anti-VEGF treated rats were significantly smaller at 2 weeks (p = 0.049) and 3 weeks (p<0.001) post laser. Conclusion The presented method of in-vivo FFA quantification of CNV, including acquisition variable corrections, using the Micron III system and common use software establishes a reliable method for detecting and quantifying CNV enabling longitudinal studies and represents an important alternative to conventional CNV quantification methods. PMID:26024231
Safety syringes and anti-needlestick devices in orthopaedic surgery.
Sibbitt, Wilmer L; Band, Philip A; Kettwich, Lawrence G; Sibbitt, Cristina R; Sibbitt, Lori J; Bankhurst, Arthur D
2011-09-07
The American Academy of Orthopaedic Surgery (AAOS), The Joint Commission, the Occupational Safety and Health Administration (OSHA), and the Needlestick Safety and Prevention Act encourage the integration of safety-engineered devices to prevent needlestick injuries to health-care workers and patients. We hypothesized that safety syringes and needles could be used in outpatient orthopaedic injection and aspiration procedures. The study investigated the orthopaedic uses and procedural idiosyncrasies of safety-engineered devices, including (1) four safety needles (Eclipse, SafetyGlide, SurGuard, and Magellan), (2) a mechanical safety syringe (RPD), (3) two automatic retractable syringes (Integra, VanishPoint), (4) three manual retractable syringes (Procedur-SF, Baksnap, Invirosnap), and (5) three shielded syringes (Safety-Lok, Monoject, and Digitally Activated Shielded [DAS] Syringe). The devices were first tested ex vivo, and then 1300 devices were used for 425 subjects undergoing outpatient arthrocentesis, intra-articular injections, local anesthesia, aspiration biopsy, and ultrasound-guided procedures. During the clinical observation, there were no accidental needlesticks (0 needlesticks per 1300 devices). Safety needles could be successfully used on a Luer syringe but were limited to ≤1.5 in (≤3.81 cm) in length and the shield could interfere with sonography. The mechanical safety syringes functioned well in all orthopaedic procedures. Automatic retractable syringes were too small for arthrocentesis of the knee, and the plunger blew out and prematurely collapsed with high-pressure injections. The manual retractable syringes and shielded syringes could be used with conventional needles for most orthopaedic procedures. The most effective and reliable safety devices for orthopaedic syringe procedures are shielded safety needles, mechanical syringes, manual retractable syringes, and shielded syringes, but not automatic retractable syringes. Even when adopting safety-engineered devices for an orthopaedic clinic, conventional syringes larger than 20 mL and conventional needles longer than 1.5 in (3.8 cm) are necessary.
Examining the contents of isolated Xenopus germinal vesicles.
Gall, Joseph G; Wu, Zheng'an
2010-05-01
One can manually isolate the giant oocyte nucleus or germinal vesicle (GV) of Xenopus from a living oocyte with nothing more complicated than jewelers' forceps and a dissecting microscope. Similarly, one can remove the nuclear envelope by hand and allow the lampbrush chromosomes and other nuclear organelles to spread on a microscope slide. After centrifugation, the nuclear contents adhere tightly to the slide, where they can be subjected to immunostaining or fluorescent in situ hybridization for visualization by conventional or confocal microscopy. Preparations of isolated GV contents reveal details of nuclear structure that are almost impossible to attain by more conventional techniques.
Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients.
Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan
2016-07-27
The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. The study was conducted at the Be'sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable.
Lalande, David; Hodd, Jeffrey A; Brousseau, John S; Ramos, Van; Dunham, Daniel; Rueggeberg, Frederick
2017-10-14
Because crowns with open margins are a well-known problem and can lead to complications, it is important to assess the accuracy of margins resulting from the use of a new technique. Currently, data regarding the marginal fit of computer-aided design and computer-aided manufacturing (CAD-CAM) technology to fabricate a complete gold crown (CGC) from a castable acrylate resin polymer block are lacking. The purpose of this in vitro study was to compare marginal discrepancy widths of CGCs fabricated by using either conventional hand waxing or acrylate resin polymer blocks generated by using CAD-CAM technology. A plastic model of a first mandibular molar was prepared by using a 1-mm, rounded chamfer margin on the entire circumference of the tooth. The master die was duplicated 30 times, and 15 wax patterns were fabricated by using a manual waxing technique, and 15 were fabricated by using CAD-CAM technology. All patterns were invested and cast, and resulting CGCs were cemented on their respective die by using resin-modified glass ionomer cement. The specimens were then embedded in acrylic resin and sectioned buccolingually. The buccal and lingual marginal discrepancies of each sectioned portion were measured by using microscopy at ×50 magnification. Data were subjected to repeated measures 2-way ANOVA, by using the Tukey post hoc pairwise comparison test (α=.05). The factor of "technique" had no significant influence on marginal discrepancy measurement (P=.431), but a significant effect of "margin location" (P=.019) was noted. The confounding combination of factors was found to be significantly lower marginal discrepancy dimensions of the lingual margin discrepancy than on the buccal side by using CAD-CAM technology. The marginal discrepancy of CAD-CAM acrylate resin crowns was not significantly different from those made with a conventional manual method; however, lingual margin discrepancies present from CAD-CAM-prepared crowns were significantly less than those measured on the respective buccal surface. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Depincé-Berger, Anne E; Moreau, Amelie; Bossy, Virginie; Genin, Christian; Rinaudo, Melanie; Paul, Stephane
2016-09-01
Indirect immunofluorescence plays a major role in the detection of antinuclear antibodies (ANAs) and follow-up of their titers in the context of connective tissue diseases. Given the numerous unfavorable features of the conventional manual reading of HEP2 slides (need of time and expert morphologists for the reading, lack of standardization, subjectivity of the interpretation), the biomedical industry has developed automated techniques of slide preparation and microscope reading. We collected 49 sera beforehand analyzed by the conventional reading of slides. They were prepared again by QUANTA-Lyser(®) and reanalyzed in four different conditions: two dilutions of screening (1/40 and 1/80), two different systems of analysis, NOVA View(®) automated reading (INOVA Diagnostics), then confirmation by the operator, and conventional manual reading by two different qualified operators. The analysis was realized in blind of the first interpretation and clinical diagnosis. The sera were classified in four groups, on the basis of the results of the first analysis: negative sera (titer < 1/160; 11 patients), low positives (titer at 1/160; 18 patients), moderated positives (titers between 1/320 and 1/640; 10 patients), and strong positives (titers between 1/1,280 and 1/2,560; 10 patients). Among the 49 patients, 13 presented a connective tissue disease including 4 systemic scleroderma (SS), 3 rheumatoid arthritis (RA), 2 Goujerot-Sjogren (GS), 2 systemic lupus erythematosus (SLE), 1 polymyositis (PM), 1 Raynaud's syndrome (RS), and 1 CREST syndrome. One patient presented both an SLE and an SS. Regarding the screening dilution, the 1/40 dilution is less specific than the 1/80 dilution for both the systems of analysis (5.6% vs. 16.7% for the manual reading, and 27.8% vs. 50% for the automated reading). It also generates statistically more false positives (P = 0.037 for the conventional analysis and P = 0.003 for the automated system). The automated NOVA View(®) reading of slides allows a gain in specificity for both dilutions, and also statistically less false positives (P = 0.002 at the 1/40 and P = 0.0006 at the 1/80), and detriment of the sensitivity at the highest dilution (84.6% vs. 92.3% with manual reading). Thus, according to our analysis of 49 sera, the automated NOVA View(®) system of reading of slides at the dilution 1/80 seems to be a successful condition for the detection of ANAs on HEP2 cells, close to the significance (P = 0.067). The automated NOVA View(®) reading of slides allows saving time, and an improvement in the standardization. Nevertheless, it requires a confirmation by a qualified operator, to interpret mixed patterns in particular. © 2016 Wiley Periodicals, Inc.
CAVE3: A general transient heat transfer computer code utilizing eigenvectors and eigenvalues
NASA Technical Reports Server (NTRS)
Palmieri, J. V.; Rathjen, K. A.
1978-01-01
The method of solution is a hybrid analytical numerical technique which utilizes eigenvalues and eigenvectors. The method is inherently stable, permitting large time steps even with the best of conductors with the finest of mesh sizes which can provide a factor of five reduction in machine time compared to conventional explicit finite difference methods when structures with small time constants are analyzed over long time periods. This code will find utility in analyzing hypersonic missile and aircraft structures which fall naturally into this class. The code is a completely general one in that problems involving any geometry, boundary conditions and materials can be analyzed. This is made possible by requiring the user to establish the thermal network conductances between nodes. Dynamic storage allocation is used to minimize core storage requirements. This report is primarily a user's manual for CAVE3 code. Input and output formats are presented and explained. Sample problems are included which illustrate the usage of the code as well as establish the validity and accuracy of the method.
Applications of laser ultrasound NDT methods on composite structures in aerospace industry
NASA Astrophysics Data System (ADS)
Kalms, Michael; Focke, Oliver; v. Kopylow, Christoph
2008-09-01
Composite materials are used more and more in aircraft production. Main composite types are Carbon Fiber Reinforced Plastics (CFRP), Glass Fiber Reinforced Plastics (GFRP) and metal-aluminium laminates (e. g. Glass Fiber Aluminium Reinforced GLARE©). Typical parts made of CFRP material are flaps, vertical and horizontal tail planes, center wing boxes, rear pressure bulkheads, ribs and stringers. These composite parts require adequate nondestructive testing (NDT) methods. Flaws to be detected are delaminations and debondings, porosity and foreign body inclusion. Manual ultrasonic testing with single element transducers is still the most applied method for composite parts with small and medium size. The extension of the conventional ultrasound technique for nondestructive testing with the laser ultrasound method brings new possibilities into the production processes for example the inspection of complex CFRP-components and the possibilities of online observation under remote control. In this paper we describe the principle of laser ultrasound with respect to the demands of nondestructive testing especially of small complex CFRP and C/PPS parts. We report applications of laser-based ultrasound options with generated types of guided and bulk waves on modern aircraft materials.
Golbaz, Isabelle; Ahlers, Christian; Goesseringer, Nina; Stock, Geraldine; Geitzenauer, Wolfgang; Prünte, Christian; Schmidt-Erfurth, Ursula Margarethe
2011-03-01
This study compared automatic- and manual segmentation modalities in the retina of healthy eyes using high-definition optical coherence tomography (HD-OCT). Twenty retinas in 20 healthy individuals were examined using an HD-OCT system (Carl Zeiss Meditec, Inc.). Three-dimensional imaging was performed with an axial resolution of 6 μm at a maximum scanning speed of 25,000 A-scans/second. Volumes of 6 × 6 × 2 mm were scanned. Scans were analysed using a matlab-based algorithm and a manual segmentation software system (3D-Doctor). The volume values calculated by the two methods were compared. Statistical analysis revealed a high correlation between automatic and manual modes of segmentation. The automatic mode of measuring retinal volume and the corresponding three-dimensional images provided similar results to the manual segmentation procedure. Both methods were able to visualize retinal and subretinal features accurately. This study compared two methods of assessing retinal volume using HD-OCT scans in healthy retinas. Both methods were able to provide realistic volumetric data when applied to raster scan sets. Manual segmentation methods represent an adequate tool with which to control automated processes and to identify clinically relevant structures, whereas automatic procedures will be needed to obtain data in larger patient populations. © 2009 The Authors. Journal compilation © 2009 Acta Ophthalmol.
NASA Technical Reports Server (NTRS)
Arya, Vinod K.; Halford, Gary R. (Technical Monitor)
2003-01-01
This manual presents computer programs FLAPS for characterizing and predicting fatigue and creep-fatigue resistance of metallic materials in the high-temperature, long-life regime for isothermal and nonisothermal fatigue. The programs use the Total Strain version of Strainrange Partitioning (TS-SRP), and several other life prediction methods described in this manual. The user should be thoroughly familiar with the TS-SRP and these life prediction methods before attempting to use any of these programs. Improper understanding can lead to incorrect use of the method and erroneous life predictions. An extensive database has also been developed in a parallel effort. The database is probably the largest source of high-temperature, creep-fatigue test data available in the public domain and can be used with other life-prediction methods as well. This users' manual, software, and database are all in the public domain and can be obtained by contacting the author. The Compact Disk (CD) accompanying this manual contains an executable file for the FLAPS program, two datasets required for the example problems in the manual, and the creep-fatigue data in a format compatible with these programs.
Vogeser, Michael; Spöhrer, Ute
2006-01-01
Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is an efficient technology for routine determination of immunosuppressants in whole blood; however, time-consuming manual sample preparation remains a significant limitation of this technique. Using a commercially available robotic pipetting system (Tecan Freedom EVO), we developed an automated sample-preparation protocol for quantification of tacrolimus in whole blood by LC-MS/MS. Barcode reading, sample resuspension, transfer of whole blood aliquots into a deep-well plate, addition of internal standard solution, mixing, and protein precipitation by addition of an organic solvent is performed by the robotic system. After centrifugation of the plate, the deproteinized supernatants are submitted to on-line solid phase extraction, using column switching prior to LC-MS/MS analysis. The only manual actions within the entire process are decapping of the tubes, and transfer of the deep-well plate from the robotic system to a centrifuge and finally to the HPLC autosampler. Whole blood pools were used to assess the reproducibility of the entire analytical system for measuring tacrolimus concentrations. A total coefficient of variation of 1.7% was found for the entire automated analytical process (n=40; mean tacrolimus concentration, 5.3 microg/L). Close agreement between tacrolimus results obtained after manual and automated sample preparation was observed. The analytical system described here, comprising automated protein precipitation, on-line solid phase extraction and LC-MS/MS analysis, is convenient and precise, and minimizes hands-on time and the risk of mistakes in the quantification of whole blood immunosuppressant concentrations compared to conventional methods.
Lesion Detection in CT Images Using Deep Learning Semantic Segmentation Technique
NASA Astrophysics Data System (ADS)
Kalinovsky, A.; Liauchuk, V.; Tarasau, A.
2017-05-01
In this paper, the problem of automatic detection of tuberculosis lesion on 3D lung CT images is considered as a benchmark for testing out algorithms based on a modern concept of Deep Learning. For training and testing of the algorithms a domestic dataset of 338 3D CT scans of tuberculosis patients with manually labelled lesions was used. The algorithms which are based on using Deep Convolutional Networks were implemented and applied in three different ways including slice-wise lesion detection in 2D images using semantic segmentation, slice-wise lesion detection in 2D images using sliding window technique as well as straightforward detection of lesions via semantic segmentation in whole 3D CT scans. The algorithms demonstrate superior performance compared to algorithms based on conventional image analysis methods.
NASA Astrophysics Data System (ADS)
Chisholm, Bret J.; Webster, Dean C.; Bennett, James C.; Berry, Missy; Christianson, David; Kim, Jongsoo; Mayo, Bret; Gubbins, Nathan
2007-07-01
An automated, high-throughput adhesion workflow that enables pseudobarnacle adhesion and coating/substrate adhesion to be measured on coating patches arranged in an array format on 4×8in.2 panels was developed. The adhesion workflow consists of the following process steps: (1) application of an adhesive to the coating array; (2) insertion of panels into a clamping device; (3) insertion of aluminum studs into the clamping device and onto coating surfaces, aligned with the adhesive; (4) curing of the adhesive; and (5) automated removal of the aluminum studs. Validation experiments comparing data generated using the automated, high-throughput workflow to data obtained using conventional, manual methods showed that the automated system allows for accurate ranking of relative coating adhesion performance.
Bridging the gap: simulations meet knowledge bases
NASA Astrophysics Data System (ADS)
King, Gary W.; Morrison, Clayton T.; Westbrook, David L.; Cohen, Paul R.
2003-09-01
Tapir and Krill are declarative languages for specifying actions and agents, respectively, that can be executed in simulation. As such, they bridge the gap between strictly declarative knowledge bases and strictly executable code. Tapir and Krill components can be combined to produce models of activity which can answer questions about mechanisms and processes using conventional inference methods and simulation. Tapir was used in DARPA's Rapid Knowledge Formation (RKF) project to construct models of military tactics from the Army Field Manual FM3-90. These were then used to build Courses of Actions (COAs) which could be critiqued by declarative reasoning or via Monte Carlo simulation. Tapir and Krill can be read and written by non-knowledge engineers making it an excellent vehicle for Subject Matter Experts to build and critique knowledge bases.
Fully Automatic Segmentation of Fluorescein Leakage in Subjects With Diabetic Macular Edema
Rabbani, Hossein; Allingham, Michael J.; Mettu, Priyatham S.; Cousins, Scott W.; Farsiu, Sina
2015-01-01
Purpose. To create and validate software to automatically segment leakage area in real-world clinical fluorescein angiography (FA) images of subjects with diabetic macular edema (DME). Methods. Fluorescein angiography images obtained from 24 eyes of 24 subjects with DME were retrospectively analyzed. Both video and still-frame images were obtained using a Heidelberg Spectralis 6-mode HRA/OCT unit. We aligned early and late FA frames in the video by a two-step nonrigid registration method. To remove background artifacts, we subtracted early and late FA frames. Finally, after postprocessing steps, including detection and inpainting of the vessels, a robust active contour method was utilized to obtain leakage area in a 1500-μm-radius circular region centered at the fovea. Images were captured at different fields of view (FOVs) and were often contaminated with outliers, as is the case in real-world clinical imaging. Our algorithm was applied to these images with no manual input. Separately, all images were manually segmented by two retina specialists. The sensitivity, specificity, and accuracy of manual interobserver, manual intraobserver, and automatic methods were calculated. Results. The mean accuracy was 0.86 ± 0.08 for automatic versus manual, 0.83 ± 0.16 for manual interobserver, and 0.90 ± 0.08 for manual intraobserver segmentation methods. Conclusions. Our fully automated algorithm can reproducibly and accurately quantify the area of leakage of clinical-grade FA video and is congruent with expert manual segmentation. The performance was reliable for different DME subtypes. This approach has the potential to reduce time and labor costs and may yield objective and reproducible quantitative measurements of DME imaging biomarkers. PMID:25634978
Smits, Loek P.; van Wijk, Diederik F.; Duivenvoorden, Raphael; Xu, Dongxiang; Yuan, Chun; Stroes, Erik S.; Nederveen, Aart J.
2016-01-01
Purpose To study the interscan reproducibility of manual versus automated segmentation of carotid artery plaque components, and the agreement between both methods, in high and lower quality MRI scans. Methods 24 patients with 30–70% carotid artery stenosis were planned for 3T carotid MRI, followed by a rescan within 1 month. A multicontrast protocol (T1w,T2w, PDw and TOF sequences) was used. After co-registration and delineation of the lumen and outer wall, segmentation of plaque components (lipid-rich necrotic cores (LRNC) and calcifications) was performed both manually and automated. Scan quality was assessed using a visual quality scale. Results Agreement for the detection of LRNC (Cohen’s kappa (k) is 0.04) and calcification (k = 0.41) between both manual and automated segmentation methods was poor. In the high-quality scans (visual quality score ≥ 3), the agreement between manual and automated segmentation increased to k = 0.55 and k = 0.58 for, respectively, the detection of LRNC and calcification larger than 1 mm2. Both manual and automated analysis showed good interscan reproducibility for the quantification of LRNC (intraclass correlation coefficient (ICC) of 0.94 and 0.80 respectively) and calcified plaque area (ICC of 0.95 and 0.77, respectively). Conclusion Agreement between manual and automated segmentation of LRNC and calcifications was poor, despite a good interscan reproducibility of both methods. The agreement between both methods increased to moderate in high quality scans. These findings indicate that image quality is a critical determinant of the performance of both manual and automated segmentation of carotid artery plaque components. PMID:27930665
40 CFR 53.2 - General requirements for a reference method determination.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Manual methods—(1) Sulfur dioxide (SO 2 ) and lead. For measuring SO2 and lead, appendices A and G of part 50 of this chapter specify unique manual FRM for measuring these pollutants. Except as provided in § 53.16, other manual methods for SO2 and lead will not be considered for FRM determinations under this...
Association between heart rate variability and manual pulse rate.
Hart, John
2013-09-01
One model for neurological assessment in chiropractic pertains to autonomic variability, tested commonly with heart rate variability (HRV). Since HRV may not be convenient to use on all patient visits, more user-friendly methods may help fill-in the gaps. Accordingly, this study tests the association between manual pulse rate and heart rate variability. The manual rates were also compared to the heart rate derived from HRV. Forty-eight chiropractic students were examined with heart rate variability (SDNN and mean heart rate) and two manual radial pulse rate measurements. Inclusion criteria consisted of participants being chiropractic students. Exclusion criteria for 46 of the participants consisted of a body mass index being greater than 30, age greater than 35, and history of: a) dizziness upon standing, b) treatment of psychiatric disorders, and c) diabetes. No exclusion criteria were applied to the remaining two participants who were also convenience sample volunteers. Linear associations between the manual pulse rate methods and the two heart rate variability measures (SDNN and mean heart) were tested with Pearson's correlation and simple linear regression. Moderate strength inverse (expected) correlations were observed between both manual pulse rate methods and SDNN (r = -0.640, 95% CI -0.781, -0.435; r = -0.632, 95% CI -0.776, -0.425). Strong direct (expected) relationships were observed between the manual pulse rate methods and heart rate derived from HRV technology (r = 0.934, 95% CI 0.885, 0.962; r = 0.941, 95% CI 0.897, 0.966). Manual pulse rates may be a useful option for assessing autonomic variability. Furthermore, this study showed a strong relationship between manual pulse rates and heart rate derived from HRV technology.
Koehl, Bérengère; Sommet, Julie; Holvoet, Laurent; Abdoul, Hendy; Boizeau, Priscilla; Ithier, Ghislaine; Missud, Florence; Couque, Nathalie; Verlhac, Suzanne; Voultoury, Pauline; Sellami, Fatiha; Baruchel, André; Benkerrou, Malika
2016-05-01
Chronic exchange transfusion is effective for primary and secondary prevention of stroke in children with sickle cell anemia (SCA). Erythrocytapheresis is recognized to be the most efficient approach; however, it is not widely implemented and is not suitable for all patients. The aim of our study was to compare automated exchange transfusion (AET) with our manual method of exchange transfusion and, in particular, to evaluate the efficacy, safety, and cost of our manual method. Thirty-nine SCA children with stroke and/or abnormal findings on transcranial Doppler were included in the study. We retrospectively analyzed 1353 exchange sessions, including 333 sessions of AET and 1020 sessions of manual exchange transfusion (MET). Both methods were well tolerated. The median decrease in hemoglobin (Hb)S per session was 21.5% with AET and 18.8% with our manual method (p < 0.0001) with no major increase in red blood cell consumption. Iron overload was well controlled, even with the manual method, with a median (interquartile range) ferritin level of 312 (152-994) µg/L after 24 months of transfusions. The main differences in annual cost relate to equipment costs, which were 74 times higher with the automated method. Our study shows that continuous MET has comparable efficacy to the automated method in terms of stroke prevention, decrease in HbS, and iron overload prevention. It is feasible in all hospital settings and is often combined with AET successively over time. © 2016 AABB.
A Technique for Facile and Precise Transfer of Mouse Embryos
Sarvari, Ali; Naderi, Mohammad Mehdi; Sadeghi, Mohammad Reza; Akhondi, Mohammad Mehdi
2013-01-01
Background Successful Embryo Transfer (ET) technique is a fateful step of all efforts to achieve live births from in vitro produced embryos in assisted reproductive techniques or in knockout, transgenic or cloned animal projects. Small reproductive tract of mice and limitation of current techniques may not well satisfy the requirements for mass production of genetically modified mice. Genetic abnormalities of embryos, receptivity and uterine contractions, expulsion of embryos, blood, mucus or bacterial contamination on the transfer pipette tip, technical problems and even animal strain may affect embryo transfer outcome. Methods In this study, two techniques of embryo transfer in mice were compared. In conventional technique the oviduct wall was punctured with a 30-gauge needle and the loaded Pasteur pipette with embryos and medium was inserted into the hole. In new technique, embryos that were loaded in modified micropipette with minimal medium were transferred directly to the oviduct by manual piston micro-pump easily. Embryo viability was evaluated considering the percentage of live healthy newborns. Results Results of the two techniques were compared by t-test within the NPAR1WAY procedure of SAS software (ver. 9.2). The average live birth rates in the novel methods was significantly higher (42.4%) than the conventional method (21.7%, p<0.05). Conclusion In conclusion, using new embryo transfer technique improved birth rate by preventing embryos expulsion from the oviduct, saving time and easy transfer of embryos with minimum volume of medium. PMID:23626878
Computational Methods for Analyzing Health News Coverage
ERIC Educational Resources Information Center
McFarlane, Delano J.
2011-01-01
Researchers that investigate the media's coverage of health have historically relied on keyword searches to retrieve relevant health news coverage, and manual content analysis methods to categorize and score health news text. These methods are problematic. Manual content analysis methods are labor intensive, time consuming, and inherently…
Reducing false negatives in clinical practice: the role of neural network technology.
Mango, L J
1996-10-01
The fact that some cervical smears result in false-negative findings is an unavoidable and unpredictable consequence of the conventional (manual microscopic) method of screening. Errors in the detection and interpretation of abnormality are cited as leading causes of false-negative cytology findings; these are random errors that are not known to correlate with any patient risk factor, which makes the false-negative findings a "silent" threat that is difficult to prevent. Described by many as a labor-intensive procedure, the microscopic evaluation of a cervical smear involves a detailed search among hundreds of thousands of cells on each smear for a possible few that may indicate abnormality. Investigations into causes of false-negative findings preceding the discovery of high-grade lesions found that many smears had very few diagnostic cells that were often very small in size. These small cells were initially overlooked or misinterpreted and repeatedly missed on rescreening. PAPNET testing is designed to supplement conventional screening by detecting abnormal cells that initially may have been missed by microscopic examination. This interactive system uses neural networks, a type of artificial intelligence well suited for pattern recognition, to automate the arduous search for abnormality. The instrument focuses the review of suspicious cells by a trained cytologist. Clinical studies indicate that PAPNET testing is sensitive to abnormality typically missed by conventional screening and that its use as a supplemental test improves the accuracy of screening.
Piloted Evaluation of the H-Mode, a Variable Autonomy Control System, in Motion-Based Simulation
NASA Technical Reports Server (NTRS)
Goodrich, Kenneth H.; Schutte, Paul C.; Williams, Ralph A.
2008-01-01
As aircraft become able to autonomously respond to a range of situations with performance surpassing human operators, we are compelled to look for new methods that help understand their use and guide the design of new, more effective forms of automation and interaction. The "H-mode" is one such method and is based on the metaphor of a well-trained horse. The concept allows the pilot to manage a broad range of control automation functionality, from augmented manual control to FMS-like coupling and automation initiated actions, using a common interface system and easily learned set of interaction skills. The interface leverages familiar manual control interfaces (e.g., the control stick) and flight displays through the addition of contextually dependent haptic-multimodal elements. The concept is relevant to manned and remotely piloted vehicles. This paper provides an overview of the H-mode concept followed by a presentation of the results from a recent evaluation conducted in a motion-based simulator. The evaluation focused on assessing the overall usability and flying qualities of the concept with an emphasis on the effects of turbulence and cockpit motion. Because the H-mode results in interactions between traditional flying qualities and management of higher-level flight path automation, these effects are of particular interest. The results indicate that the concept may provide a useful complement or replacement to conventional interfaces, and retains the usefulness in the presence of turbulence and motion.
Manuals Used in the National Aquatic Resource Surveys
Various manuals are used to communicate the methods and guidelines for the National Aquatic Resource Surveys. The Field Operations Manual: outlines the field protocols that crews will utilize to sample sites.
Facilitating Dance Making from a Teacher's Perspective within a Community Integrated Dance Class
ERIC Educational Resources Information Center
Cheesman, Sue
2011-01-01
Integrated dance has featured in several publications from the mid-1990's onwards, particularly from the standpoints of equity of access, and contesting perceptions of dominant conventional notions of what dance is and who can dance including issues of embodiment and representation. Other publications and manuals focus primarily on how to teach…
Transfer of Training from Predictor to Conventional Displays. Interim Report.
ERIC Educational Resources Information Center
Wulfeck, J. W.
Use of a predictor display has been shown to virtually transform the difficulty of a variety of complex, manual control pursuit tracking tasks to the level of those having relatively simple control requirements. With 15-minutes practice, naive operators are able to perform some complex tasks with a predictor display at accuracy levels previously…
ERIC Educational Resources Information Center
Guidera, Stan; MacPherson, D. Scot
2008-01-01
This paper presents the results of a study that was conducted to identify and document student perceptions of the effectiveness of computer modeling software introduced in a design foundations course that had previously utilized only conventional manually-produced representation techniques. Rather than attempt to utilize a production-oriented CAD…
A region-based segmentation method for ultrasound images in HIFU therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Dong, E-mail: dongz@whu.edu.cn; Liu, Yu; Yang, Yan
Purpose: Precisely and efficiently locating a tumor with less manual intervention in ultrasound-guided high-intensity focused ultrasound (HIFU) therapy is one of the keys to guaranteeing the therapeutic result and improving the efficiency of the treatment. The segmentation of ultrasound images has always been difficult due to the influences of speckle, acoustic shadows, and signal attenuation as well as the variety of tumor appearance. The quality of HIFU guidance images is even poorer than that of conventional diagnostic ultrasound images because the ultrasonic probe used for HIFU guidance usually obtains images without making contact with the patient’s body. Therefore, the segmentationmore » becomes more difficult. To solve the segmentation problem of ultrasound guidance image in the treatment planning procedure for HIFU therapy, a novel region-based segmentation method for uterine fibroids in HIFU guidance images is proposed. Methods: Tumor partitioning in HIFU guidance image without manual intervention is achieved by a region-based split-and-merge framework. A new iterative multiple region growing algorithm is proposed to first split the image into homogenous regions (superpixels). The features extracted within these homogenous regions will be more stable than those extracted within the conventional neighborhood of a pixel. The split regions are then merged by a superpixel-based adaptive spectral clustering algorithm. To ensure the superpixels that belong to the same tumor can be clustered together in the merging process, a particular construction strategy for the similarity matrix is adopted for the spectral clustering, and the similarity matrix is constructed by taking advantage of a combination of specifically selected first-order and second-order texture features computed from the gray levels and the gray level co-occurrence matrixes, respectively. The tumor region is picked out automatically from the background regions by an algorithm according to a priori information about the tumor position, shape, and size. Additionally, an appropriate cluster number for spectral clustering can be determined by the same algorithm, thus the automatic segmentation of the tumor region is achieved. Results: To evaluate the performance of the proposed method, 50 uterine fibroid ultrasound images from different patients receiving HIFU therapy were segmented, and the obtained tumor contours were compared with those delineated by an experienced radiologist. For area-based evaluation results, the mean values of the true positive ratio, the false positive ratio, and the similarity were 94.42%, 4.71%, and 90.21%, respectively, and the corresponding standard deviations were 2.54%, 3.12%, and 3.50%, respectively. For distance-based evaluation results, the mean values of the normalized Hausdorff distance and the normalized mean absolute distance were 4.93% and 0.90%, respectively, and the corresponding standard deviations were 2.22% and 0.34%, respectively. The running time of the segmentation process was 12.9 s for a 318 × 333 (pixels) image. Conclusions: Experiments show that the proposed method can segment the tumor region accurately and efficiently with less manual intervention, which provides for the possibility of automatic segmentation and real-time guidance in HIFU therapy.« less
Ehigiator, O A; Anyata, B U
2011-11-01
This work reports runoff and soil loss from each of 14 sub-watersheds in a secondary rain forest in south-western Nigeria. The impact of methods of land clearing and post-clearing management on runoff and soil erosion under the secondary forest is evaluated. These data were acquired eighteen years after the deforestation of primary vegetation during the ' West bank' project of the International Institute for Tropical Agriculture (IITA). These data are presented separately for each season; however, statistical analyses for replicates were not conducted due to differences in their past management. Soil erosion was affected by land clearing and tillage methods. The maximum soil erosion was observed on sub-watersheds that were mechanically cleared with tree-pusher/root-rake attachments and tilled conventionally. A high rate of erosion was observed even when graded-channel terraces were constructed to minimize soil erosion. In general there was much less soil erosion on manually cleared than on mechanically cleared sub-watersheds (2.5 t ha(-1) yr(-1) versus 13.8 t ha(-1) yr(-1)) and from the application of no-tillage methods than from conventionally plowed areas (6.5 t ha(-1) yr(-1) versus 12.1 t ha(-1) yr(-1)). The data indicate that tillage methods and appropriate management of soils and crops play an important role in soil and water conservation and in decreasing the rate of decline of soil quality. Copyright © 2011 Elsevier Ltd. All rights reserved.
Zeidler-Erdely, Patti C.; Antonini, James M.; Meighan, Terence G.; Young, Shih-Houng; Eye, Tracy J.; Hammer, Mary Ann; Erdely, Aaron
2016-01-01
Pulmonary toxicity studies often use bronchoalveolar lavage (BAL) to investigate potential adverse lung responses to a particulate exposure. The BAL cellular fraction is counted, using automated (i.e. Coulter Counter®), flow cytometry or manual (i.e. hemocytometer) methods, to determine inflammatory cell influx. The goal of the study was to compare the different counting methods to determine which is optimal for examining BAL cell influx after exposure by inhalation or intratracheal instillation (ITI) to different particles with varying inherent pulmonary toxicities in both rat and mouse models. General findings indicate that total BAL cell counts using the automated and manual methods tended to agree after inhalation or ITI exposure to particle samples that are relatively nontoxic or at later time points after exposure to a pneumotoxic particle when the response resolves. However, when the initial lung inflammation and cytotoxicity was high after exposure to a pneumotoxic particle, significant differences were observed when comparing cell counts from the automated, flow cytometry and manual methods. When using total BAL cell count for differential calculations from the automated method, depending on the cell diameter size range cutoff, the data suggest that the number of lung polymorphonuclear leukocytes (PMN) varies. Importantly, the automated counts, regardless of the size cutoff, still indicated a greater number of total lung PMN when compared with the manual method, which agreed more closely with flow cytometry. The results suggest that either the manual method or flow cytometry would be better suited for BAL studies where cytotoxicity is an unknown variable. PMID:27251196
Milne, Marjorie E; Steward, Christopher; Firestone, Simon M; Long, Sam N; O'Brien, Terrence J; Moffat, Bradford A
2016-04-01
To develop representative MRI atlases of the canine brain and to evaluate 3 methods of atlas-based segmentation (ABS). 62 dogs without clinical signs of epilepsy and without MRI evidence of structural brain disease. The MRI scans from 44 dogs were used to develop 4 templates on the basis of brain shape (brachycephalic, mesaticephalic, dolichocephalic, and combined mesaticephalic and dolichocephalic). Atlas labels were generated by segmenting the brain, ventricular system, hippocampal formation, and caudate nuclei. The MRI scans from the remaining 18 dogs were used to evaluate 3 methods of ABS (manual brain extraction and application of a brain shape-specific template [A], automatic brain extraction and application of a brain shape-specific template [B], and manual brain extraction and application of a combined template [C]). The performance of each ABS method was compared by calculation of the Dice and Jaccard coefficients, with manual segmentation used as the gold standard. Method A had the highest mean Jaccard coefficient and was the most accurate ABS method assessed. Measures of overlap for ABS methods that used manual brain extraction (A and C) ranged from 0.75 to 0.95 and compared favorably with repeated measures of overlap for manual extraction, which ranged from 0.88 to 0.97. Atlas-based segmentation was an accurate and repeatable method for segmentation of canine brain structures. It could be performed more rapidly than manual segmentation, which should allow the application of computer-assisted volumetry to large data sets and clinical cases and facilitate neuroimaging research and disease diagnosis.
Zeidler-Erdely, Patti C; Antonini, James M; Meighan, Terence G; Young, Shih-Houng; Eye, Tracy J; Hammer, Mary Ann; Erdely, Aaron
2016-08-01
Pulmonary toxicity studies often use bronchoalveolar lavage (BAL) to investigate potential adverse lung responses to a particulate exposure. The BAL cellular fraction is counted, using automated (i.e. Coulter Counter®), flow cytometry or manual (i.e. hemocytometer) methods, to determine inflammatory cell influx. The goal of the study was to compare the different counting methods to determine which is optimal for examining BAL cell influx after exposure by inhalation or intratracheal instillation (ITI) to different particles with varying inherent pulmonary toxicities in both rat and mouse models. General findings indicate that total BAL cell counts using the automated and manual methods tended to agree after inhalation or ITI exposure to particle samples that are relatively nontoxic or at later time points after exposure to a pneumotoxic particle when the response resolves. However, when the initial lung inflammation and cytotoxicity was high after exposure to a pneumotoxic particle, significant differences were observed when comparing cell counts from the automated, flow cytometry and manual methods. When using total BAL cell count for differential calculations from the automated method, depending on the cell diameter size range cutoff, the data suggest that the number of lung polymorphonuclear leukocytes (PMN) varies. Importantly, the automated counts, regardless of the size cutoff, still indicated a greater number of total lung PMN when compared with the manual method, which agreed more closely with flow cytometry. The results suggest that either the manual method or flow cytometry would be better suited for BAL studies where cytotoxicity is an unknown variable.
Rolling resistance and propulsion efficiency of manual and power-assisted wheelchairs.
Pavlidou, Efthymia; Kloosterman, Marieke G M; Buurke, Jaap H; Rietman, Johan S; Janssen, Thomas W J
2015-11-01
Rolling resistance is one of the main forces resisting wheelchair propulsion and thus affecting stress exerted on the upper limbs. The present study investigates the differences in rolling resistance, propulsion efficiency and energy expenditure required by the user during power-assisted and manual propulsion. Different tire pressures (50%, 75%, 100%) and two different levels of motor assistance were tested. Drag force, energy expenditure and propulsion efficiency were measured in 10 able-bodied individuals under different experimental settings on a treadmill. Results showed that drag force levels were significantly higher in the 50%, compared to the 75% and 100% inflation conditions. In terms of wheelchair type, the manual wheelchair displayed significantly lower drag force values than the power-assisted one. The use of extra-power-assisted wheelchair appeared to be significantly superior to conventional power-assisted and manual wheelchairs concerning both propulsion efficiency and energy expenditure required by the user. Overall, the results of the study suggest that the use of power-assisted wheelchair was more efficient and required less energy input by the user, depending on the motor assistance provided. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Zhang, Lin; Huttin, Olivier; Marie, Pierre-Yves; Felblinger, Jacques; Beaumont, Marine; Chillou, Christian DE; Girerd, Nicolas; Mandry, Damien
2016-11-01
To compare three widely used methods for myocardial infarct (MI) sizing on late gadolinium-enhanced (LGE) magnetic resonance (MR) images: manual delineation and two semiautomated techniques (full-width at half-maximum [FWHM] and n-standard deviation [SD]). 3T phase-sensitive inversion-recovery (PSIR) LGE images of 114 patients after an acute MI (2-4 days and 6 months) were analyzed by two independent observers to determine both total and core infarct sizes (TIS/CIS). Manual delineation served as the reference for determination of optimal thresholds for semiautomated methods after thresholding at multiple values. Reproducibility and accuracy were expressed as overall bias ± 95% limits of agreement. Mean infarct sizes by manual methods were 39.0%/24.4% for the acute MI group (TIS/CIS) and 29.7%/17.3% for the chronic MI group. The optimal thresholds (ie, providing the closest mean value to the manual method) were FWHM30% and 3SD for the TIS measurement and FWHM45% and 6SD for the CIS measurement (paired t-test; all P > 0.05). The best reproducibility was obtained using FWHM. For TIS measurement in the acute MI group, intra-/interobserver agreements, from Bland-Altman analysis, with FWHM30%, 3SD, and manual were -0.02 ± 7.74%/-0.74 ± 5.52%, 0.31 ± 9.78%/2.96 ± 16.62% and -2.12 ± 8.86%/0.18 ± 16.12, respectively; in the chronic MI group, the corresponding values were 0.23 ± 3.5%/-2.28 ± 15.06, -0.29 ± 10.46%/3.12 ± 13.06% and 1.68 ± 6.52%/-2.88 ± 9.62%, respectively. A similar trend for reproducibility was obtained for CIS measurement. However, semiautomated methods produced inconsistent results (variabilities of 24-46%) compared to manual delineation. The FWHM technique was the most reproducible method for infarct sizing both in acute and chronic MI. However, both FWHM and n-SD methods showed limited accuracy compared to manual delineation. J. Magn. Reson. Imaging 2016;44:1206-1217. © 2016 International Society for Magnetic Resonance in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burgmans, Mark Christiaan, E-mail: m.c.burgmans@lumc.nl; Harder, J. Michiel den, E-mail: chiel.den.harder@gmail.com; Meershoek, Philippa, E-mail: P.Meershoek@lumc.nl
PurposeTo determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions.Materials and MethodsCT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined bymore » measurement of the residual displacement in phantom lesions by two independent observers.ResultsMean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values.ConclusionThe accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.« less
SIDS-toADF File Mapping Manual
NASA Technical Reports Server (NTRS)
McCarthy, Douglas; Smith, Matthew; Poirier, Diane; Smith, Charles A. (Technical Monitor)
2002-01-01
The "CFD General Notation System" (CGNS) consists of a collection of conventions, and conforming software, for the storage and retrieval of Computational Fluid Dynamics (CFD) data. It facilitates the exchange of data between sites and applications, and helps stabilize the archiving of aerodynamic data. This effort was initiated in order to streamline the procedures in exchanging data and software between NASA and its customers, but the goal is to develop CGNS into a National Standard for the exchange of aerodynamic data. The CGNS development team is comprised of members from Boeing Commercial Airplane Group, NASA-Ames, NASA-Langley, NASA-Lewis, McDonnell-Douglas Corporation (now Boeing-St. Louis), Air Force-Wright Lab., and ICEM-CFD Engineering. The elements of CGNS address all activities associated with the storage of data on external media and its movement to and from application programs. These elements include: 1) The Advanced Data Format (ADF) Database manager, consisting of both a file format specification and its I/O software, which handles the actual reading and writing of data from and to external storage media; 2) The Standard Interface Data Structures (SIDS), which specify the intellectual content of CFD data and the conventions governing naming and terminology; 3) The SIDS-to-ADF File Mapping conventions, which specify the exact location where the CFD data defined by the SIDS is to be stored within the ADF file(s); and 4) The CGNS Mid-level Library, which provides CFD-knowledgeable routines suitable for direct installation into application codes. The SIDS-toADF File Mapping Manual specifies the exact manner in which, under CGNS conventions, CFD data structures (the SIDS) are to be stored in (i.e., mapped onto) the file structure provided by the database manager (ADF). The result is a conforming CGNS database. Adherence to the mapping conventions guarantees uniform meaning and location of CFD data within ADF files, and thereby allows the construction of universal software to read and write the data.
SRM Manual, Selected Resource Materials: Description and Evaluation.
ERIC Educational Resources Information Center
Alberta Dept. of Education, Edmonton. Special Educational Services Branch.
Provided in the manual is descriptive and evaluative information on 67 instructional materials or programs frequently used with exceptional children in Alberta schools. A flow chart describes the three methods of using the manual: l) to obtain descriptive and evaluative information of an instruction program in the manual 2) to classify and record…
A Self-Adapting System for the Automated Detection of Inter-Ictal Epileptiform Discharges
Lodder, Shaun S.; van Putten, Michel J. A. M.
2014-01-01
Purpose Scalp EEG remains the standard clinical procedure for the diagnosis of epilepsy. Manual detection of inter-ictal epileptiform discharges (IEDs) is slow and cumbersome, and few automated methods are used to assist in practice. This is mostly due to low sensitivities, high false positive rates, or a lack of trust in the automated method. In this study we aim to find a solution that will make computer assisted detection more efficient than conventional methods, while preserving the detection certainty of a manual search. Methods Our solution consists of two phases. First, a detection phase finds all events similar to epileptiform activity by using a large database of template waveforms. Individual template detections are combined to form “IED nominations”, each with a corresponding certainty value based on the reliability of their contributing templates. The second phase uses the ten nominations with highest certainty and presents them to the reviewer one by one for confirmation. Confirmations are used to update certainty values of the remaining nominations, and another iteration is performed where ten nominations with the highest certainty are presented. This continues until the reviewer is satisfied with what has been seen. Reviewer feedback is also used to update template accuracies globally and improve future detections. Key Findings Using the described method and fifteen evaluation EEGs (241 IEDs), one third of all inter-ictal events were shown after one iteration, half after two iterations, and 74%, 90%, and 95% after 5, 10 and 15 iterations respectively. Reviewing fifteen iterations for the 20–30 min recordings 1took approximately 5 min. Significance The proposed method shows a practical approach for combining automated detection with visual searching for inter-ictal epileptiform activity. Further evaluation is needed to verify its clinical feasibility and measure the added value it presents. PMID:24454813
[Manual therapy in general practice].
Березуцкий, Владимир И
2016-01-01
The article is devoted to manual therapy practice for diagnostics and treatment of vertebrogenic pain syndrome in general practice. Analytical roundup of sources proves medical advantage of implementation of manual therapy basic methods by general practice specialists.
Parmar, Chintan; Blezek, Daniel; Estepar, Raul San Jose; Pieper, Steve; Kim, John; Aerts, Hugo J. W. L.
2017-01-01
Purpose Accurate segmentation of lung nodules is crucial in the development of imaging biomarkers for predicting malignancy of the nodules. Manual segmentation is time consuming and affected by inter-observer variability. We evaluated the robustness and accuracy of a publically available semiautomatic segmentation algorithm that is implemented in the 3D Slicer Chest Imaging Platform (CIP) and compared it with the performance of manual segmentation. Methods CT images of 354 manually segmented nodules were downloaded from the LIDC database. Four radiologists performed the manual segmentation and assessed various nodule characteristics. The semiautomatic CIP segmentation was initialized using the centroid of the manual segmentations, thereby generating four contours for each nodule. The robustness of both segmentation methods was assessed using the region of uncertainty (δ) and Dice similarity index (DSI). The robustness of the segmentation methods was compared using the Wilcoxon-signed rank test (pWilcoxon<0.05). The Dice similarity index (DSIAgree) between the manual and CIP segmentations was computed to estimate the accuracy of the semiautomatic contours. Results The median computational time of the CIP segmentation was 10 s. The median CIP and manually segmented volumes were 477 ml and 309 ml, respectively. CIP segmentations were significantly more robust than manual segmentations (median δCIP = 14ml, median dsiCIP = 99% vs. median δmanual = 222ml, median dsimanual = 82%) with pWilcoxon~10−16. The agreement between CIP and manual segmentations had a median DSIAgree of 60%. While 13% (47/354) of the nodules did not require any manual adjustment, minor to substantial manual adjustments were needed for 87% (305/354) of the nodules. CIP segmentations were observed to perform poorly (median DSIAgree≈50%) for non-/sub-solid nodules with subtle appearances and poorly defined boundaries. Conclusion Semi-automatic CIP segmentation can potentially reduce the physician workload for 13% of nodules owing to its computational efficiency and superior stability compared to manual segmentation. Although manual adjustment is needed for many cases, CIP segmentation provides a preliminary contour for physicians as a starting point. PMID:28594880
Benefits of Manometer in Non-Invasive Ventilatory Support.
Lacerda, Rodrigo Silva; de Lima, Fernando Cesar Anastácio; Bastos, Leonardo Pereira; Fardin Vinco, Anderson; Schneider, Felipe Britto Azevedo; Luduvico Coelho, Yves; Fernandes, Heitor Gomes Costa; Bacalhau, João Marcus Ramos; Bermudes, Igor Matheus Simonelli; da Silva, Claudinei Ferreira; da Silva, Luiza Paterlini; Pezato, Rogério
2017-12-01
Introduction Effective ventilation during cardiopulmonary resuscitation (CPR) is essential to reduce morbidity and mortality rates in cardiac arrest. Hyperventilation during CPR reduces the efficiency of compressions and coronary perfusion. Problem How could ventilation in CPR be optimized? The objective of this study was to evaluate non-invasive ventilator support using different devices. The study compares the regularity and intensity of non-invasive ventilation during simulated, conventional CPR and ventilatory support using three distinct ventilation devices: a standard manual resuscitator, with and without airway pressure manometer, and an automatic transport ventilator. Student's t-test was used to evaluate statistical differences between groups. P values <.05 were regarded as significant. Peak inspiratory pressure during ventilatory support and CPR was significantly increased in the group with manual resuscitator without manometer when compared with the manual resuscitator with manometer support (MS) group or automatic ventilator (AV) group. The study recommends for ventilatory support the use of a manual resuscitator equipped with MS or AVs, due to the risk of reduction in coronary perfusion pressure and iatrogenic thoracic injury during hyperventilation found using manual resuscitator without manometer. Lacerda RS , de Lima FCA , Bastos LP , Vinco AF , Schneider FBA , Coelho YL , Fernandes HGC , Bacalhau JMR , Bermudes IMS , da Silva CF , da Silva LP , Pezato R . Benefits of manometer in non-invasive ventilatory support. Prehosp Disaster Med. 2017;32(6):615-620.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberts, Nathan V.
2016-09-28
Camellia began as an effort to simplify implementation of efficient solvers for the discontinuous Petrov-Galerkin (DPG) finite element methodology of Demkowicz and Gopalakrishnan. Since then, the feature set has expanded, to allow implementation of traditional continuous Galerkin methods, as well as discontinuous Galerkin (DG) methods, hybridizable DG (HDG) methods, first-order-system least squares (FOSLS), and the primal DPG method. This manual serves as an introduction to using Camellia. We begin, in Section 1.1, by describing some of the core features of Camellia. In Section 1.2 we provide an outline of the manual as a whole.
NASA Astrophysics Data System (ADS)
Liu, Xin; Lu, Hongbing; Chen, Hanyong; Zhao, Li; Shi, Zhengxing; Liang, Zhengrong
2009-02-01
Developmental dysplasia of the hip is a congenital hip joint malformation affecting the proximal femurs and acetabulum that are subluxatable, dislocatable, and dislocated. Conventionally, physicians made diagnoses and treatments only based on findings from two-dimensional (2D) images by manually calculating clinic parameters. However, anatomical complexity of the disease and the limitation of current standard procedures make accurate diagnosis quite difficultly. In this study, we developed a system that provides quantitative measurement of 3D clinical indexes based on computed tomography (CT) images. To extract bone structure from surrounding tissues more accurately, the system firstly segments the bone using a knowledge-based fuzzy clustering method, which is formulated by modifying the objective function of the standard fuzzy c-means algorithm with additive adaptation penalty. The second part of the system calculates automatically the clinical indexes, which are extended from 2D to 3D for accurate description of spatial relationship between femurs and acetabulum. To evaluate the system performance, experimental study based on 22 patients with unilateral or bilateral affected hip was performed. The results of 3D acetabulum index (AI) automatically provided by the system were validated by comparison with 2D results measured by surgeons manually. The correlation between the two results was found to be 0.622 (p<0.01).
Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey
Arbogast, Belinda F.
1996-01-01
The analytical methods validated by the Mineral Resource Surveys Program, Geologic Division, is the subject of this manual. This edition replaces the methods portion of Open-File Report 90-668 published in 1990. Newer methods may be used which have been approved by the quality assurance (QA) project and are on file with the QA coordinator.This manual is intended primarily for use by laboratory scientists; this manual can also assist laboratory users to evaluate the data they receive. The analytical methods are written in a step by step approach so that they may be used as a training tool and provide detailed documentation of the procedures for quality assurance. A "Catalog of Services" is available for customer (submitter) use with brief listings of:the element(s)/species determined,method of determination,reference to cite,contact person,summary of the technique,and analyte concentration range.For a copy please contact the Branch office at (303) 236-1800 or fax (303) 236-3200.
Mixed methods research - the best of both worlds?
van Griensven, Hubert; Moore, Ann P; Hall, Valerie
2014-10-01
There has been a bias towards quantitative research approaches within manual therapy, which may have resulted in a narrow understanding of manual therapy practice. The aim of this Masterclass is to make a contribution to the expansion of methodologies used in manual therapy enquiry by discussing mixed methods research (MMR), a methodology which utilises both qualitative and quantitative methods within a single study in order to provide more comprehensive insights. To review rationales for MMR, as well as some of the common design options and potential difficulties. The paper also discusses theoretical frameworks that have been used to underpin qualitative and quantitative research, and ongoing debates about the possibility of combining them. Complexities associated with health and manual therapy cannot always be investigated satisfactorily by using a single research method. Some issues require a more comprehensive understanding, which may be provided by combining the strengths of quantitative and qualitative methods in a mixed methods study. Copyright © 2014 Elsevier Ltd. All rights reserved.
Multi-label literature classification based on the Gene Ontology graph.
Jin, Bo; Muller, Brian; Zhai, Chengxiang; Lu, Xinghua
2008-12-08
The Gene Ontology is a controlled vocabulary for representing knowledge related to genes and proteins in a computable form. The current effort of manually annotating proteins with the Gene Ontology is outpaced by the rate of accumulation of biomedical knowledge in literature, which urges the development of text mining approaches to facilitate the process by automatically extracting the Gene Ontology annotation from literature. The task is usually cast as a text classification problem, and contemporary methods are confronted with unbalanced training data and the difficulties associated with multi-label classification. In this research, we investigated the methods of enhancing automatic multi-label classification of biomedical literature by utilizing the structure of the Gene Ontology graph. We have studied three graph-based multi-label classification algorithms, including a novel stochastic algorithm and two top-down hierarchical classification methods for multi-label literature classification. We systematically evaluated and compared these graph-based classification algorithms to a conventional flat multi-label algorithm. The results indicate that, through utilizing the information from the structure of the Gene Ontology graph, the graph-based multi-label classification methods can significantly improve predictions of the Gene Ontology terms implied by the analyzed text. Furthermore, the graph-based multi-label classifiers are capable of suggesting Gene Ontology annotations (to curators) that are closely related to the true annotations even if they fail to predict the true ones directly. A software package implementing the studied algorithms is available for the research community. Through utilizing the information from the structure of the Gene Ontology graph, the graph-based multi-label classification methods have better potential than the conventional flat multi-label classification approach to facilitate protein annotation based on the literature.
NASA Astrophysics Data System (ADS)
Trusiak, M.; Patorski, K.; Tkaczyk, T.
2014-12-01
We propose a fast, simple and experimentally robust method for reconstructing background-rejected optically-sectioned microscopic images using two-shot structured illumination approach. Innovative data demodulation technique requires two grid-illumination images mutually phase shifted by π (half a grid period) but precise phase displacement value is not critical. Upon subtraction of the two frames the input pattern with increased grid modulation is computed. The proposed demodulation procedure comprises: (1) two-dimensional data processing based on the enhanced, fast empirical mode decomposition (EFEMD) method for the object spatial frequency selection (noise reduction and bias term removal), and (2) calculating high contrast optically-sectioned image using the two-dimensional spiral Hilbert transform (HS). The proposed algorithm effectiveness is compared with the results obtained for the same input data using conventional structured-illumination (SIM) and HiLo microscopy methods. The input data were collected for studying highly scattering tissue samples in reflectance mode. In comparison with the conventional three-frame SIM technique we need one frame less and no stringent requirement on the exact phase-shift between recorded frames is imposed. The HiLo algorithm outcome is strongly dependent on the set of parameters chosen manually by the operator (cut-off frequencies for low-pass and high-pass filtering and η parameter value for optically-sectioned image reconstruction) whereas the proposed method is parameter-free. Moreover very short processing time required to efficiently demodulate the input pattern predestines proposed method for real-time in-vivo studies. Current implementation completes full processing in 0.25s using medium class PC (Inter i7 2,1 GHz processor and 8 GB RAM). Simple modification employed to extract only first two BIMFs with fixed filter window size results in reducing the computing time to 0.11s (8 frames/s).
Burgmans, Mark Christiaan; den Harder, J Michiel; Meershoek, Philippa; van den Berg, Nynke S; Chan, Shaun Xavier Ju Min; van Leeuwen, Fijs W B; van Erkel, Arian R
2017-06-01
To determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions. CT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined by measurement of the residual displacement in phantom lesions by two independent observers. Mean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values. The accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.
An Improved Manual Method for NOx Emission Measurement.
ERIC Educational Resources Information Center
Dee, L. A.; And Others
The current manual NO (x) sampling and analysis method was evaluated. Improved time-integrated sampling and rapid analysis methods were developed. In the new method, the sample gas is drawn through a heated bed of uniquely active, crystalline, Pb02 where NO (x) is quantitatively absorbed. Nitrate ion is later extracted with water and the…
NASA Astrophysics Data System (ADS)
Peng, Yahui; Jiang, Yulei; Soylu, Fatma N.; Tomek, Mark; Sensakovic, William; Oto, Aytekin
2012-02-01
Quantitative analysis of multi-parametric magnetic resonance (MR) images of the prostate, including T2-weighted (T2w) and diffusion-weighted (DW) images, requires accurate image registration. We compared two registration methods between T2w and DW images. We collected pre-operative MR images of 124 prostate cancer patients (68 patients scanned with a GE scanner and 56 with Philips scanners). A landmark-based rigid registration was done based on six prostate landmarks in both T2w and DW images identified by a radiologist. Independently, a researcher manually registered the same images. A radiologist visually evaluated the registration results by using a 5-point ordinal scale of 1 (worst) to 5 (best). The Wilcoxon signed-rank test was used to determine whether the radiologist's ratings of the results of the two registration methods were significantly different. Results demonstrated that both methods were accurate: the average ratings were 4.2, 3.3, and 3.8 for GE, Philips, and all images, respectively, for the landmark-based method; and 4.6, 3.7, and 4.2, respectively, for the manual method. The manual registration results were more accurate than the landmark-based registration results (p < 0.0001 for GE, Philips, and all images). Therefore, the manual method produces more accurate registration between T2w and DW images than the landmark-based method.
TU-H-BRC-01: A New Fabrication Method for Secondary Skin Collimation Using 3D Scanner and 3D Printer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jung, J; Potter, N; Suh, T
Purpose: Using secondary skin collimation (SSC) to protect the critical organ surrounding the tumors is always desirable for electron and/or ortho-voltage treatments. However, the time-consuming and labor-intensive fabrication processes of current method (manually fabricate the lead mask) restrict the general use of SSC. The aim of this study is to develop a new SSC fabrication method using 3D scanning and 3D printing technologies in order to largely decrease the human labor involvement and fabrication time, also improve the fabrication accuracy. Methods: First, the patient surface was scanned with a 3D scanner (Structure Sensor, Occipital, CO). The raw scan data wasmore » subsequently transferred to a 3D modeling software (Rhinoceros, Ver. 5.0, McNeel North America, Seattle, WA). The tumor contour was then digitized and shielding region was determined by clinicians in the same software. The corresponding SCC conformed to the skin surface was then automatically generated by the software with the proper shielding thickness. The shell of the SCC (with hollow inside) was consequently printed by a 3D printer (Lulzbot TAZ, Aleph Objects, CO) using plastic material. Finally, the hollow mold of SCC was filled up with a melted cerrobend alloy. Once the cerrobend alloy cooled down, the fabrication of SCC was accomplished. Results: The results indicated the proposed method can achieve a much shorter time on making a SCC compared with tradition fabrication method. The processes of making a skin contour model for patients have been eliminated with the new method. SCC created by the new method possessed better accuracy and better conformality to patient’s skin contours. Conclusion: In this study, we have demonstrated a new method for the SCC fabrication. It is anticipated that our method can be an alternative way to replace conventional manual-based methods for electron and/or ortho-voltage SCC fabrication. This research was supported by the Global Ph.D. Fellowship Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (Grant No. 2015H1A2A1034071), Republic of Korea.« less
ERIC Educational Resources Information Center
Lindsay, Gordon B.; Merrill, Ray M.; Owens, Adam; Barleen, Nathan A.
2008-01-01
Background: There is some debate over the efficacy of alcohol industry parenting manuals. Purpose: This study compares the content and focus of alcohol industry and non-industry "talk to your child about drinking" parenting manuals. Methods: Parenting manuals from Anheuser-Busch and Miller Brewing Company were compared to federal government and…
NASA Astrophysics Data System (ADS)
Barlow, Steven J.
1986-09-01
The Air Force needs a better method of designing new and retrofit heating, ventilating and air conditioning (HVAC) control systems. Air Force engineers currently use manual design/predict/verify procedures taught at the Air Force Institute of Technology, School of Civil Engineering, HVAC Control Systems course. These existing manual procedures are iterative and time-consuming. The objectives of this research were to: (1) Locate and, if necessary, modify an existing computer-based method for designing and analyzing HVAC control systems that is compatible with the HVAC Control Systems manual procedures, or (2) Develop a new computer-based method of designing and analyzing HVAC control systems that is compatible with the existing manual procedures. Five existing computer packages were investigated in accordance with the first objective: MODSIM (for modular simulation), HVACSIM (for HVAC simulation), TRNSYS (for transient system simulation), BLAST (for building load and system thermodynamics) and Elite Building Energy Analysis Program. None were found to be compatible or adaptable to the existing manual procedures, and consequently, a prototype of a new computer method was developed in accordance with the second research objective.
Cerebella segmentation on MR images of pediatric patients with medulloblastoma
NASA Astrophysics Data System (ADS)
Shan, Zu Y.; Ji, Qing; Glass, John; Gajjar, Amar; Reddick, Wilburn E.
2005-04-01
In this study, an automated method has been developed to identify the cerebellum from T1-weighted MR brain images of patients with medulloblastoma. A new objective function that is similar to Gibbs free energy in classic physics was defined; and the brain structure delineation was viewed as a process of minimizing Gibbs free energy. We used a rigid-body registration and an active contour (snake) method to minimize the Gibbs free energy in this study. The method was applied to 20 patient data sets to generate cerebellum images and volumetric results. The generated cerebellum images were compared with two manually drawn results. Strong correlations were found between the automatically and manually generated volumetric results, the correlation coefficients with each of manual results were 0.971 and 0.974, respectively. The average Jaccard similarities with each of two manual results were 0.89 and 0.88, respectively. The average Kappa indexes with each of two manual results were 0.94 and 0.93, respectively. These results showed this method was both robust and accurate for cerebellum segmentation. The method may be applied to various research and clinical investigation in which cerebellum segmentation and quantitative MR measurement of cerebellum are needed.
Computer aided diagnosis of diabetic foot using infrared thermography: A review.
Adam, Muhammad; Ng, Eddie Y K; Tan, Jen Hong; Heng, Marabelle L; Tong, Jasper W K; Acharya, U Rajendra
2017-12-01
Diabetes mellitus (DM) is a chronic metabolic disorder that requires regular medical care to prevent severe complications. The elevated blood glucose level affects the eyes, blood vessels, nerves, heart, and kidneys after the onset. The affected blood vessels (usually due to atherosclerosis) may lead to insufficient blood circulation particularly in the lower extremities and nerve damage (neuropathy), which can result in serious foot complications. Hence, an early detection and treatment can prevent foot complications such as ulcerations and amputations. Clinicians often assess the diabetic foot for sensory deficits with clinical tools, and the resulting foot severity is often manually evaluated. The infrared thermography is a fast, nonintrusive and non-contact method which allows the visualization of foot plantar temperature distribution. Several studies have proposed infrared thermography-based computer aided diagnosis (CAD) methods for diabetic foot. Among them, the asymmetric temperature analysis method is more superior, as it is easy to implement, and yielded satisfactory results in most of the studies. In this paper, the diabetic foot, its pathophysiology, conventional assessments methods, infrared thermography and the different infrared thermography-based CAD analysis methods are reviewed. Copyright © 2017 Elsevier Ltd. All rights reserved.
Iris registration in wavefront-guided LASIK to correct mixed astigmatism.
Khalifa, Mounir; El-Kateb, Mohamed; Shaheen, Mohamed Shafik
2009-03-01
To investigate the predictability, safety, and efficiency of wavefront-guided laser in situ keratomileusis (LASIK) with iris-registration technology to correct mixed astigmatism. Vision correction center, Alexandria, Egypt. This retrospective double-blind study included randomly selected patients with mixed astigmatism who sought laser refractive surgery. Patients were divided equally into 3 groups and treated with conventional LASIK and manual marking, wavefront-guided LASIK and manual marking, or wavefront-guided LASIK with iris registration (LASIK+IR group). Eyes were analyzed preoperatively and up to 3 months postoperatively. The LASIK+IR group had better postoperative uncorrected visual acuity (100% 20/30 or better; 90% 20/20 or better; 20% 20/16 or better) than the other groups and did not lose preoperative best spectacle-corrected visual acuity, unlike the other groups. This group also had the highest percentage of eyes that gained lines of acuity (20% 1 line; 10% 2 lines). The LASIK+IR group had the highest predictability of spherical refraction (80% within +/-0.50 diopter [D]; 100% within +/-1.00 D [P<.05] and the highest predictability of cylinder refraction. The LASIK+IR eyes had a significantly smaller increase postoperatively in coma, trefoil, and secondary astigmatism. There was no significant difference between groups in spherical aberration or quadrafoil. The LASIK-IR group had the most improvement in scotopic contrast sensitivity (P<.05). Wavefront-guided LASIK with iris registration was more predictable, safe, and efficient than conventional or wavefront-guided LASIK with manual marking in correcting mixed astigmatism. Further studies are needed to confirm these results.
Huang, Jianyan; Maram, Jyotsna; Tepelus, Tudor C; Modak, Cristina; Marion, Ken; Sadda, SriniVas R; Chopra, Vikas; Lee, Olivia L
2017-08-07
To determine the reliability of corneal endothelial cell density (ECD) obtained by automated specular microscopy versus that of validated manual methods and factors that predict such reliability. Sharp central images from 94 control and 106 glaucomatous eyes were captured with Konan specular microscope NSP-9900. All images were analyzed by trained graders using Konan CellChek Software, employing the fully- and semi-automated methods as well as Center Method. Images with low cell count (input cells number <100) and/or guttata were compared with the Center and Flex-Center Methods. ECDs were compared and absolute error was used to assess variation. The effect on ECD of age, cell count, cell size, and cell size variation was evaluated. No significant difference was observed between the Center and Flex-Center Methods in corneas with guttata (p=0.48) or low ECD (p=0.11). No difference (p=0.32) was observed in ECD of normal controls <40 yrs old between the fully-automated method and manual Center Method. However, in older controls and glaucomatous eyes, ECD was overestimated by the fully-automated method (p=0.034) and semi-automated method (p=0.025) as compared to manual method. Our findings show that automated analysis significantly overestimates ECD in the eyes with high polymegathism and/or large cell size, compared to the manual method. Therefore, we discourage reliance upon the fully-automated method alone to perform specular microscopy analysis, particularly if an accurate ECD value is imperative. Copyright © 2017. Published by Elsevier España, S.L.U.
Exponential error reduction in pretransfusion testing with automation.
South, Susan F; Casina, Tony S; Li, Lily
2012-08-01
Protecting the safety of blood transfusion is the top priority of transfusion service laboratories. Pretransfusion testing is a critical element of the entire transfusion process to enhance vein-to-vein safety. Human error associated with manual pretransfusion testing is a cause of transfusion-related mortality and morbidity and most human errors can be eliminated by automated systems. However, the uptake of automation in transfusion services has been slow and many transfusion service laboratories around the world still use manual blood group and antibody screen (G&S) methods. The goal of this study was to compare error potentials of commonly used manual (e.g., tiles and tubes) versus automated (e.g., ID-GelStation and AutoVue Innova) G&S methods. Routine G&S processes in seven transfusion service laboratories (four with manual and three with automated G&S methods) were analyzed using failure modes and effects analysis to evaluate the corresponding error potentials of each method. Manual methods contained a higher number of process steps ranging from 22 to 39, while automated G&S methods only contained six to eight steps. Corresponding to the number of the process steps that required human interactions, the risk priority number (RPN) of the manual methods ranged from 5304 to 10,976. In contrast, the RPN of the automated methods was between 129 and 436 and also demonstrated a 90% to 98% reduction of the defect opportunities in routine G&S testing. This study provided quantitative evidence on how automation could transform pretransfusion testing processes by dramatically reducing error potentials and thus would improve the safety of blood transfusion. © 2012 American Association of Blood Banks.
The manual lists and describes the instruments and techniques that are available for measuring the concentration or size distribution of particles suspended in process streams. The standard, official, well established methods are described as well as some experimental methods and...
NASA Astrophysics Data System (ADS)
Jian, Wang; Xiaohong, Meng; Hong, Liu; Wanqiu, Zheng; Yaning, Liu; Sheng, Gui; Zhiyang, Wang
2017-03-01
Full waveform inversion and reverse time migration are active research areas for seismic exploration. Forward modeling in the time domain determines the precision of the results, and numerical solutions of finite difference have been widely adopted as an important mathematical tool for forward modeling. In this article, the optimum combined of window functions was designed based on the finite difference operator using a truncated approximation of the spatial convolution series in pseudo-spectrum space, to normalize the outcomes of existing window functions for different orders. The proposed combined window functions not only inherit the characteristics of the various window functions, to provide better truncation results, but also control the truncation error of the finite difference operator manually and visually by adjusting the combinations and analyzing the characteristics of the main and side lobes of the amplitude response. Error level and elastic forward modeling under the proposed combined system were compared with outcomes from conventional window functions and modified binomial windows. Numerical dispersion is significantly suppressed, which is compared with modified binomial window function finite-difference and conventional finite-difference. Numerical simulation verifies the reliability of the proposed method.
Ibrahim, Sarah A; Martini, Luigi
2014-08-01
Dissolution method transfer is a complicated yet common process in the pharmaceutical industry. With increased pharmaceutical product manufacturing and dissolution acceptance requirements, dissolution testing has become one of the most labor-intensive quality control testing methods. There is an increased trend for automation in dissolution testing, particularly for large pharmaceutical companies to reduce variability and increase personnel efficiency. There is no official guideline for dissolution testing method transfer from a manual, semi-automated, to automated dissolution tester. In this study, a manual multipoint dissolution testing procedure for an enteric-coated aspirin tablet was transferred effectively and reproducibly to a fully automated dissolution testing device, RoboDis II. Enteric-coated aspirin samples were used as a model formulation to assess the feasibility and accuracy of media pH change during continuous automated dissolution testing. Several RoboDis II parameters were evaluated to ensure the integrity and equivalency of dissolution method transfer from a manual dissolution tester. This current study provides a systematic outline for the transfer of the manual dissolution testing protocol to an automated dissolution tester. This study further supports that automated dissolution testers compliant with regulatory requirements and similar to manual dissolution testers facilitate method transfer. © 2014 Society for Laboratory Automation and Screening.
Petrographic methods of examining hardened concrete : a petrographic manual.
DOT National Transportation Integrated Search
1997-11-01
This manual was undertaken to record for all persons wishing to do concrete : petrography the petrographic procedures that have been found useful at the : Virginia Transportation Research Council. The manual is made up of an : introduction and chapte...
Calibration of highway safety manual work zone crash modification factors.
DOT National Transportation Integrated Search
2014-06-01
The Highway Safety Manual is the national safety manual that provides quantitative methods for analyzing highway safety. The : HSM presents crash modification factors related to work zone characteristics such as work zone duration and length. These c...
NASA Technical Reports Server (NTRS)
Elliott, R. D.; Werner, N. M.; Baker, W. M.
1975-01-01
The Aerodynamic Data Analysis and Integration System (ADAIS), developed as a highly interactive computer graphics program capable of manipulating large quantities of data such that addressable elements of a data base can be called up for graphic display, compared, curve fit, stored, retrieved, differenced, etc., was described. The general nature of the system is evidenced by the fact that limited usage has already occurred with data bases consisting of thermodynamic, basic loads, and flight dynamics data. Productivity using ADAIS of five times that for conventional manual methods of wind tunnel data analysis is routinely achieved. In wind tunnel data analysis, data from one or more runs of a particular test may be called up and displayed along with data from one or more runs of a different test. Curves may be faired through the data points by any of four methods, including cubic spline and least squares polynomial fit up to seventh order.
An intelligent system for real time automatic defect inspection on specular coated surfaces
NASA Astrophysics Data System (ADS)
Li, Jinhua; Parker, Johné M.; Hou, Zhen
2005-07-01
Product visual inspection is still performed manually or semi automatically in most industries from simple ceramic tile grading to complex automotive body panel paint defect and surface quality inspection. Moreover, specular surfaces present additional challenge to conventional vision systems due to specular reflections, which may mask the true location of objects and lead to incorrect measurements. There are some sophisticated visual inspection methods developed in recent years. Unfortunately, most of them are highly computational. Systems built on those methods are either inapplicable or very costly to achieve real time inspection. In this paper, we describe an integrated low-cost intelligent system developed to automatically capture, extract, and segment defects on specular surfaces with uniform color coatings. The system inspects and locates regular surface defects with lateral dimensions as small as a millimeter. The proposed system is implemented on a group of smart cameras using its on-board processing ability to achieve real time inspection. The experimental results on real test panels demonstrate the effectiveness and robustness of proposed system.
Campillo-Gimenez, Boris; Garcelon, Nicolas; Jarno, Pascal; Chapplain, Jean Marc; Cuggia, Marc
2013-01-01
The surveillance of Surgical Site Infections (SSI) contributes to the management of risk in French hospitals. Manual identification of infections is costly, time-consuming and limits the promotion of preventive procedures by the dedicated teams. The introduction of alternative methods using automated detection strategies is promising to improve this surveillance. The present study describes an automated detection strategy for SSI in neurosurgery, based on textual analysis of medical reports stored in a clinical data warehouse. The method consists firstly, of enrichment and concept extraction from full-text reports using NOMINDEX, and secondly, text similarity measurement using a vector space model. The text detection was compared to the conventional strategy based on self-declaration and to the automated detection using the diagnosis-related group database. The text-mining approach showed the best detection accuracy, with recall and precision equal to 92% and 40% respectively, and confirmed the interest of reusing full-text medical reports to perform automated detection of SSI.
Gingival Retraction Methods for Fabrication of Fixed Partial Denture: Literature Review
S, Safari; Ma, Vossoghi Sheshkalani; Mi, Vossoghi Sheshkalani; F, Hoseini Ghavam; M, Hamedi
2016-01-01
Fixed dental prosthesis success requires appropriate impression taking of the prepared finish line. This is critical in either tooth supported fixed prosthesis (crown and bridge) or implant supported fixed prosthesis (solid abutment). If the prepared finish line is adjacent to the gingival sulcus, gingival retraction techniques should be used to decrease the marginal discrepancy among the restoration and the prepared abutment. Accurate marginal positioning of the restoration in the prepared finish line of the abutment is required for therapeutic, preventive and aesthetic purposes. In this article, conventional and modern methods of gingival retraction in the fixed tooth supported prosthesis and fixed implant supported prosthesis are expressed. PubMed and Google Scholar databases were searched manually for studies on gingival tissue managements prior to impression making in fixed dental prosthesis since 1975. Conclusions were extracted and summarized. Keywords were impression making, gingival retraction, cordless retraction, and implant. Gingival retraction techniques can be classified as mechanical, chemical or surgical. In this article, different gingival management techniques are discussed. PMID:28959744
Gingival Retraction Methods for Fabrication of Fixed Partial Denture: Literature Review.
S, Safari; Ma, Vossoghi Sheshkalani; Mi, Vossoghi Sheshkalani; F, Hoseini Ghavam; M, Hamedi
2016-06-01
Fixed dental prosthesis success requires appropriate impression taking of the prepared finish line. This is critical in either tooth supported fixed prosthesis (crown and bridge) or implant supported fixed prosthesis (solid abutment). If the prepared finish line is adjacent to the gingival sulcus, gingival retraction techniques should be used to decrease the marginal discrepancy among the restoration and the prepared abutment. Accurate marginal positioning of the restoration in the prepared finish line of the abutment is required for therapeutic, preventive and aesthetic purposes. In this article, conventional and modern methods of gingival retraction in the fixed tooth supported prosthesis and fixed implant supported prosthesis are expressed. PubMed and Google Scholar databases were searched manually for studies on gingival tissue managements prior to impression making in fixed dental prosthesis since 1975. Conclusions were extracted and summarized. Keywords were impression making, gingival retraction, cordless retraction, and implant. Gingival retraction techniques can be classified as mechanical, chemical or surgical. In this article, different gingival management techniques are discussed.
NASA Technical Reports Server (NTRS)
Hopkins, Dale A.; Patnaik, Surya N.
2000-01-01
A preliminary aircraft engine design methodology is being developed that utilizes a cascade optimization strategy together with neural network and regression approximation methods. The cascade strategy employs different optimization algorithms in a specified sequence. The neural network and regression methods are used to approximate solutions obtained from the NASA Engine Performance Program (NEPP), which implements engine thermodynamic cycle and performance analysis models. The new methodology is proving to be more robust and computationally efficient than the conventional optimization approach of using a single optimization algorithm with direct reanalysis. The methodology has been demonstrated on a preliminary design problem for a novel subsonic turbofan engine concept that incorporates a wave rotor as a cycle-topping device. Computations of maximum thrust were obtained for a specific design point in the engine mission profile. The results (depicted in the figure) show a significant improvement in the maximum thrust obtained using the new methodology in comparison to benchmark solutions obtained using NEPP in a manual design mode.
Machine Vision Applied to Navigation of Confined Spaces
NASA Technical Reports Server (NTRS)
Briscoe, Jeri M.; Broderick, David J.; Howard, Ricky; Corder, Eric L.
2004-01-01
The reliability of space related assets has been emphasized after the second loss of a Space Shuttle. The intricate nature of the hardware being inspected often requires a complete disassembly to perform a thorough inspection which can be difficult as well as costly. Furthermore, it is imperative that the hardware under inspection not be altered in any other manner than that which is intended. In these cases the use of machine vision can allow for inspection with greater frequency using less intrusive methods. Such systems can provide feedback to guide, not only manually controlled instrumentation, but autonomous robotic platforms as well. This paper serves to detail a method using machine vision to provide such sensing capabilities in a compact package. A single camera is used in conjunction with a projected reference grid to ascertain precise distance measurements. The design of the sensor focuses on the use of conventional components in an unconventional manner with the goal of providing a solution for systems that do not require or cannot accommodate more complex vision systems.
Classification of speech dysfluencies using LPC based parameterization techniques.
Hariharan, M; Chee, Lim Sin; Ai, Ooi Chia; Yaacob, Sazali
2012-06-01
The goal of this paper is to discuss and compare three feature extraction methods: Linear Predictive Coefficients (LPC), Linear Prediction Cepstral Coefficients (LPCC) and Weighted Linear Prediction Cepstral Coefficients (WLPCC) for recognizing the stuttered events. Speech samples from the University College London Archive of Stuttered Speech (UCLASS) were used for our analysis. The stuttered events were identified through manual segmentation and were used for feature extraction. Two simple classifiers namely, k-nearest neighbour (kNN) and Linear Discriminant Analysis (LDA) were employed for speech dysfluencies classification. Conventional validation method was used for testing the reliability of the classifier results. The study on the effect of different frame length, percentage of overlapping, value of ã in a first order pre-emphasizer and different order p were discussed. The speech dysfluencies classification accuracy was found to be improved by applying statistical normalization before feature extraction. The experimental investigation elucidated LPC, LPCC and WLPCC features can be used for identifying the stuttered events and WLPCC features slightly outperforms LPCC features and LPC features.
Acupuncture for functional dyspepsia.
Lan, Lei; Zeng, Fang; Liu, Guan J; Ying, Li; Wu, Xi; Liu, Mailan; Liang, Fan-Rong
2014-10-13
Functional dyspepsia (FD) has been a worldwide complaint. More effective therapies are needed with fewer adverse effects than are seen with conventional medications. Acupuncture, as a traditional therapeutic method, has been widely used for functional gastrointestinal disorders in the East. Manual acupuncture and electroacupuncture have been recognized treatments for FD, but to date, no robust evidence has been found for the effectiveness and safety of these interventions in the treatment of this condition. This review was conducted to assess the efficacy and safety of manual acupuncture and electroacupuncture in the treatment of FD. Trials meeting the inclusion criteria were identified through electronic searches of the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, the Allied and Complementary Medicine Database (AMED), Chinese Biology Medicine Disc (CBMdisc), China National Knowledge Infrastructure (CNKI), the Wanfang Database, the VIP Database, and six trial registries. Handsearching was done to screen the reference sections of potential trials and reviews. Randomized controlled trials (RCTs) were included if investigators reported efficacy and safety of manual acupuncture or electroacupuncture for patients with FD diagnosed by Rome II or Rome III criteria, compared with medications, blank control, or sham acupuncture. Data were extracted by independent review authors. Study limitations were assessed by using the tool of The Cochrane Collabration for assessing risk of bias. For dichotomous data, risk ratios (RRs) and 95% confidence intervals (95% CIs) would be applied, and for continuous data, mean differences (MDs) and 95% CIs. A fixed-effect model was applied in the meta-analysis, or a descriptive analysis was performed. The quality of evidence for the outcome measure was assessed by the Grading of Recommendations Assessment, Development and Evaluation (GRADE) methods. Seven studies were included in the review, involving 542 participants with FD (212 males and 330 females). These studies generally had an unclear risk of bias based on inadequate descriptions of allocation concealment and a high risk of bias based on lack of blinding. None of the studies reported on outcomes of the Functional Digestive Disorder Quality of Life questionnaire (FDDQL), the Satisfaction With Dyspepsia Related Health scale (SODA), the Digestive Health Status Instrument (DHSI), or effective/inefficient rate and symptom recurrence six months from completion of acupuncture treatment.Four RCTs of acupuncture versus medications (cisapride, domperidone, and itopride) were included in the review. No statistically significant difference was noted in the reduction in FD symptom scores and the frequency of FD attack by manual acupuncture, manual-electroacupuncture, or electroacupuncture compared with medications. In three trials of acupuncture versus sham acupuncture, all descriptive or quantitative analysis results implied that acupuncture could improve FD symptom scores and scores on the Neck Disability Index (NDI), the 36-Item Short Form Health Survey (SF-36), the Self-Rating Anxiety Scale (SAS), and the Self-Rating Depression Scale (SDS) more or as significantly as sham acupuncture. With regard to adverse effects, acupuncture was superior to cisapride treatment (one study; all minor events), but no statistically significant difference was reported between acupuncture and sham acupuncture. No adverse effects data were reported in studies examining manual acupuncture versus domperidone, manual-electroacupuncture versus domperidone, or electroacupuncture versus itopride.Nevertheless, all evidence was of low or very low quality. The body of evidence identified cannot yet permit a robust conclusion regarding the efficacy and safety of acupuncture for FD. It remains unknown whether manual acupuncture or electroacupuncture is more effective or safer than other treatments for patients with FD.
1980-02-08
hours 0 Input Format: Integer b. Creatina Rescource Allocation Blocks The creation of a specific resource allocation block as a directive component is...is directed. 0 Range: N/A . Input Format: INT/NUC/CHM b. Creatina Employment Packages An employment package block has the structure portrayed in Figure
Design of novel non-contact multimedia controller for disability by using visual stimulus.
Pan, Jeng-Shyang; Lo, Chi-Chun; Tsai, Shang-Ho; Lin, Bor-Shyh
2015-12-01
The design of a novel non-contact multimedia controller is proposed in this study. Nowadays, multimedia controllers are generally used by patients and nursing assistants in the hospital. Conventional multimedia controllers usually involve in manual operation or other physical movements. However, it is more difficult for the disabled patients to operate the conventional multimedia controller by themselves; they might totally depend on others. Different from other multimedia controllers, the proposed system provides a novel concept of controlling multimedia via visual stimuli, without manual operation. The disabled patients can easily operate the proposed multimedia system by focusing on the control icons of a visual stimulus device, where a commercial tablet is used as the visual stimulus device. Moreover, a wearable and wireless electroencephalogram (EEG) acquisition device is also designed and implemented to easily monitor the user's EEG signals in daily life. Finally, the proposed system has been validated. The experimental result shows that the proposed system can effectively measure and extract the EEG feature related to visual stimuli, and its information transfer rate is also good. Therefore, the proposed non-contact multimedia controller exactly provides a good prototype of novel multimedia controlling scheme. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Manual method of visually identifying candidate signals for a targeted peptide.
Filimonov, Aleksey; Kopylov, Arthur; Lisitsa, Andrey; Archakov, Alexander
2018-04-15
The purpose of this study is to improve peptide signal identification in groups of extracted ion chromatograms (XICs) obtained with the liquid chromatography-selected reaction monitoring (LC-SRM) technique and a triple quadrupole mass spectrometer (QqQ) operating in one of the supported multiple reaction monitoring (MRM) modes. The imperfection of quadrupole mass analyzers causes ion interference, which impedes the identification of peptide signals as chromatographic peak groups in relevant retention time intervals. To investigate this problem in depth, the QqQ conversion of the eluate into XIC groups was considered as the consecutive transformations of the particles' abundances as the corresponding functions of retention time. In this study, the hypothesis that, during this conversion, the same chromatographic profile should be preserved as an implicit sign in each chromatographic peak of the signal was confirmed for peptides. To examine chromatographic profiles, continuous transformations of XIC groups were derived and implemented in srm2prot Express software (s2pe, http://msr.ibmc.msk.ru/s2pe). Because of ion interference, several peptide-like signals may appear in one XIC group. Therefore, these signals must be considered candidates for a targeted peptide's signal and should be resolved after identification. The theoretical investigation of intensity functions as XICs that are not distorted by noise produced three rules for Identifying Candidate Signals for a targeted Peptide (ICSP, http://msr.ibmc.msk.ru/ICSP) that constitute the proposed manual visual method. We theoretically and experimentally compared this method with the conventional semiempirical intuitive technique and found that the former significantly streamlines peptide signal identification and avoids typical errors. Copyright © 2018 Elsevier B.V. All rights reserved.
Automated Morphological Analysis of Microglia After Stroke.
Heindl, Steffanie; Gesierich, Benno; Benakis, Corinne; Llovera, Gemma; Duering, Marco; Liesz, Arthur
2018-01-01
Microglia are the resident immune cells of the brain and react quickly to changes in their environment with transcriptional regulation and morphological changes. Brain tissue injury such as ischemic stroke induces a local inflammatory response encompassing microglial activation. The change in activation status of a microglia is reflected in its gradual morphological transformation from a highly ramified into a less ramified or amoeboid cell shape. For this reason, the morphological changes of microglia are widely utilized to quantify microglial activation and studying their involvement in virtually all brain diseases. However, the currently available methods, which are mainly based on manual rating of immunofluorescent microscopic images, are often inaccurate, rater biased, and highly time consuming. To address these issues, we created a fully automated image analysis tool, which enables the analysis of microglia morphology from a confocal Z-stack and providing up to 59 morphological features. We developed the algorithm on an exploratory dataset of microglial cells from a stroke mouse model and validated the findings on an independent data set. In both datasets, we could demonstrate the ability of the algorithm to sensitively discriminate between the microglia morphology in the peri-infarct and the contralateral, unaffected cortex. Dimensionality reduction by principal component analysis allowed to generate a highly sensitive compound score for microglial shape analysis. Finally, we tested for concordance of results between the novel automated analysis tool and the conventional manual analysis and found a high degree of correlation. In conclusion, our novel method for the fully automatized analysis of microglia morphology shows excellent accuracy and time efficacy compared to traditional analysis methods. This tool, which we make openly available, could find application to study microglia morphology using fluorescence imaging in a wide range of brain disease models.
NASA Astrophysics Data System (ADS)
Tripathi, K.
2013-01-01
In automated manual clutch (AMC) a mechatronic system controls clutch force trajectory through an actuator governed by a control system. The present study identifies relevant characteristics of this trajectory and their effects on driveline dynamics and engagement quality. A new type of force trajectory is identified which gives the good engagement quality. However this trajectory is not achievable through conventional clutch control mechanism. But in AMC a mechatronic system based on electro-hydraulic or electro-mechanical elements can make it feasible. A mechatronic system is presented in which a mechatronic add-on system can be used to implement the novel force trajectory, without the requirement of replacing the traditional diaphragm spring based clutch in a vehicle with manual transmission.
In order to establish a safe environment for nurses and patients, the American Nurses Association (ANA) supports actions and policies that result in the elimination of manual patient handling. Patient handling, such as lifting, repositioning, and transferring, has conventionally been performed by nurses. The performance of these tasks exposes nurses to increased risk for work-related musculoskeletal disorders. With the development of assistive equipment, such as lift and transfer devices, the risk of musculoskeletal injury can be significantly reduced. Effective use of assistive equipment and devices for patient handling creates a safe healthcare environment by separating the physical burden from the nurse and ensuring the safety, comfort, and dignity of the patient.
Fully automatic segmentation of fluorescein leakage in subjects with diabetic macular edema.
Rabbani, Hossein; Allingham, Michael J; Mettu, Priyatham S; Cousins, Scott W; Farsiu, Sina
2015-01-29
To create and validate software to automatically segment leakage area in real-world clinical fluorescein angiography (FA) images of subjects with diabetic macular edema (DME). Fluorescein angiography images obtained from 24 eyes of 24 subjects with DME were retrospectively analyzed. Both video and still-frame images were obtained using a Heidelberg Spectralis 6-mode HRA/OCT unit. We aligned early and late FA frames in the video by a two-step nonrigid registration method. To remove background artifacts, we subtracted early and late FA frames. Finally, after postprocessing steps, including detection and inpainting of the vessels, a robust active contour method was utilized to obtain leakage area in a 1500-μm-radius circular region centered at the fovea. Images were captured at different fields of view (FOVs) and were often contaminated with outliers, as is the case in real-world clinical imaging. Our algorithm was applied to these images with no manual input. Separately, all images were manually segmented by two retina specialists. The sensitivity, specificity, and accuracy of manual interobserver, manual intraobserver, and automatic methods were calculated. The mean accuracy was 0.86 ± 0.08 for automatic versus manual, 0.83 ± 0.16 for manual interobserver, and 0.90 ± 0.08 for manual intraobserver segmentation methods. Our fully automated algorithm can reproducibly and accurately quantify the area of leakage of clinical-grade FA video and is congruent with expert manual segmentation. The performance was reliable for different DME subtypes. This approach has the potential to reduce time and labor costs and may yield objective and reproducible quantitative measurements of DME imaging biomarkers. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.
Qu, Zhenhong; Ghorbani, Rhonda P; Li, Hongyan; Hunter, Robert L; Hannah, Christina D
2007-03-01
Gross examination, encompassing description, dissection, and sampling, is a complex task and an essential component of surgical pathology. Because of the complexity of the task, standardized protocols to guide the gross examination often become a bulky manual that is difficult to use. This problem is further compounded by the high specimen volume and biohazardous nature of the task. As a result, such a manual is often underused, leading to errors that are potentially harmful and time consuming to correct-a common chronic problem affecting many pathology laboratories. To combat this problem, we have developed a simple method that incorporates complex text and graphic information of a typical procedure manual and yet allows easy access to any intended instructive information in the manual. The method uses the Object-Linking-and-Embedding function of Microsoft Word (Microsoft, Redmond, WA) to establish hyperlinks among different contents, and then it uses the touch screen technology to facilitate navigation through the manual on a computer screen installed at the cutting bench with no need for a physical keyboard or a mouse. It takes less than 4 seconds to reach any intended information in the manual by 3 to 4 touches on the screen. A 3-year follow-up study shows that this method has increased use of the manual and has improved the quality of gross examination. The method is simple and can be easily tailored to different formats of instructive information, allowing flexible organization, easy access, and quick navigation. Increased compliance to instructive information reduces errors at the grossing bench and improves work efficiency.
Application of surface geophysics to ground-water investigations
Zohdy, Adel A.R.; Eaton, Gordon P.; Mabey, Don R.
1974-01-01
This manual reviews the standard methods of surface geophysics applicable to ground-water investigations. It covers electrical methods, seismic and gravity methods, and magnetic methods. The general physical principles underlying each method and its capabilities and limitations are described. Possibilities for non-uniqueness of interpretation of geophysical results are noted. Examples of actual use of the methods are given to illustrate applications and interpretation in selected geohydrologic environments. The objective of the manual is to provide the hydrogeologist with a sufficient understanding of the capabilities, imitations, and relative cost of geophysical methods to make sound decisions as to when to use of these methods is desirable. The manual also provides enough information for the hydrogeologist to work with a geophysicist in designing geophysical surveys that differentiate significant hydrogeologic changes.
Mulder, Emma R; de Jong, Remko A; Knol, Dirk L; van Schijndel, Ronald A; Cover, Keith S; Visser, Pieter J; Barkhof, Frederik; Vrenken, Hugo
2014-05-15
To measure hippocampal volume change in Alzheimer's disease (AD) or mild cognitive impairment (MCI), expert manual delineation is often used because of its supposed accuracy. It has been suggested that expert outlining yields poorer reproducibility as compared to automated methods, but this has not been investigated. To determine the reproducibilities of expert manual outlining and two common automated methods for measuring hippocampal atrophy rates in healthy aging, MCI and AD. From the Alzheimer's Disease Neuroimaging Initiative (ADNI), 80 subjects were selected: 20 patients with AD, 40 patients with mild cognitive impairment (MCI) and 20 healthy controls (HCs). Left and right hippocampal volume change between baseline and month-12 visit was assessed by using expert manual delineation, and by the automated software packages FreeSurfer (longitudinal processing stream) and FIRST. To assess reproducibility of the measured hippocampal volume change, both back-to-back (BTB) MPRAGE scans available for each visit were analyzed. Hippocampal volume change was expressed in μL, and as a percentage of baseline volume. Reproducibility of the 1-year hippocampal volume change was estimated from the BTB measurements by using linear mixed model to calculate the limits of agreement (LoA) of each method, reflecting its measurement uncertainty. Using the delta method, approximate p-values were calculated for the pairwise comparisons between methods. Statistical analyses were performed both with inclusion and exclusion of visibly incorrect segmentations. Visibly incorrect automated segmentation in either one or both scans of a longitudinal scan pair occurred in 7.5% of the hippocampi for FreeSurfer and in 6.9% of the hippocampi for FIRST. After excluding these failed cases, reproducibility analysis for 1-year percentage volume change yielded LoA of ±7.2% for FreeSurfer, ±9.7% for expert manual delineation, and ±10.0% for FIRST. Methods ranked the same for reproducibility of 1-year μL volume change, with LoA of ±218 μL for FreeSurfer, ±319 μL for expert manual delineation, and ±333 μL for FIRST. Approximate p-values indicated that reproducibility was better for FreeSurfer than for manual or FIRST, and that manual and FIRST did not differ. Inclusion of failed automated segmentations led to worsening of reproducibility of both automated methods for 1-year raw and percentage volume change. Quantitative reproducibility values of 1-year microliter and percentage hippocampal volume change were roughly similar between expert manual outlining, FIRST and FreeSurfer, but FreeSurfer reproducibility was statistically significantly superior to both manual outlining and FIRST after exclusion of failed segmentations. Copyright © 2014 Elsevier Inc. All rights reserved.
Ayrapetova, N S; Eremushkin, M A; Antonovich, I V; Kuznetsov, O F; Samorukov, A E; Budylin, S P; Tarasova, L Yu; Derevnina, N A
The objective of the present study was to identify the peculiar features and advantages of different methods for the mechanical impact on the thoracic tissues of the patients presenting with chronic obstructive pulmonary disease (COPD) and to develop specific indications for their clinical applications. This randomized prospective comparative study included 137 patients with COPD. In accordance with the currently accepted classification (GOLD, 2013), all the patients had COPD of medium severity. The smoldering inflammatory process was diagnosed in 75 (54.7%) patients, grade I and II respiratory insufficiency in 80 (58.4%) and 57 (41.6%) patients, respectively. The external respiration function was evaluated by means of pneumotachometry techniques during the forced expiratory maneuver and by spirometry. The pulmonary hemodynamics and myocardial contractility of the right ventricle were studied with the use of rheopulmonography and central hemodynamics by tetrapolar thoracic rheography. The routine inflammatory and immune tests were employed. Investigations of the systemic circulation have demonstrated the prevalence of its hyperkinetic type (54,0%) over the hypokinetic and eukinetic ones (23,3% and 22,7% respectively). All the patients were divided into three group identical in terms of clinical and functional characteristics. The patients comprising group 1 (n=46) were prescribed the rehabilitative treatment in the form of classical chest massage, those of group 2 (n=47) were treated by means of intense massage of asymmetric chest zones, and the patients included in group 3 (n=44) underwent manual therapy. It was shown that intense massage produced the most pronounced beneficial effect. Classical massage also resulted in the reduction of the inflammatory manifestations but its effectiveness was significantly lower than that of the intense treatment (р<0,05-0,02). Manual therapy failed to cause any appreciable changes in the character and severity of the inflammatory process (р>0,5). The intense massage of asymmetric chest zones proved to provide the most efficient tool for the anti-inflammatory treatment of the patients presenting with chronic obstructive pulmonary disease in comparison with other known methods for the mechanical impact on the thoracic tissues. However, the application of this technique is limited in the patients with the hypokinetic type of systemic circulation and pulmonary hypertension. The most important advantage of chest massage by the conventional method is the possibility of its application for the treatment of the patients suffering from severe forms of COPD associated with pulmonary and systemic cardiohemodynamic disturbances with alveolar hypoxia. Manual therapy can be recommended in the first place to the patients with COPD in remission and the accompanying functional blockade of the vertebral segments.
NASA Astrophysics Data System (ADS)
Fernandez-Gonzalez, Rodrigo; Deschamps, Thomas; Idica, Adam; Malladi, Ravikanth; Ortiz de Solorzano, Carlos
2003-07-01
In this paper we present a scheme for real time segmentation of histological structures in microscopic images of normal and neoplastic mammary gland sections. Paraffin embedded or frozen tissue blocks are sliced, and sections are stained with hematoxylin and eosin (H&E). The sections are then imaged using conventional bright field microscopy. The background of the images is corrected by arithmetic manipulation using a "phantom." Then we use the fast marching method with a speed function that depends on the brightness gradient of the image to obtain a preliminary approximation to the boundaries of the structures of interest within a region of interest (ROI) of the entire section manually selected by the user. We use the result of the fast marching method as the initial condition for the level set motion equation. We run this last method for a few steps and obtain the final result of the segmentation. These results can be connected from section to section to build a three-dimensional reconstruction of the entire tissue block that we are studying.
Applicator Training Manual for: Public Health Pest Control.
ERIC Educational Resources Information Center
Moore, E. E.
This manual gives the life cycle and habitats, public health importance, methods of non-chemical control, and pesticides and methods of application for mosquitoes, flies, bedbugs, fleas, lice, cockroaches, venomous anthropods, ticks and chiggers, and rodents. (BB)
Applying the highway safety manual to Georgia.
DOT National Transportation Integrated Search
2015-08-01
This report examines the Highway Safety Manual (HSM) from the perspective of applying its : methods and approaches within the state of Georgia. The work presented here focuses : specifically on data requirements and methods that may be of particular ...
Comparison of piezosurgery and conventional rotative instruments in direct sinus lifting.
Delilbasi, Cagri; Gurler, Gokhan
2013-12-01
The purpose of this study was to compare the intraoperative and postoperative effects of Piezosurgery and conventional rotative instruments in direct sinus lifting procedure. Twenty-three patients requiring direct sinus lifting were enrolled. The osteotomy and sinus membrane elevation were performed either with Piezosurgery tips or rotative diamond burs and manual membrane elevators. Time elapsed between bony window opening and completion of membrane elevation (duration), incidence of membrane perforation, visibility of the operation site, postoperative pain, swelling, sleeping, eating, phonetics, daily routine, and missed work as well as patient's expectation before and experience after the operation were evaluated. There was no significant difference between Piezosurgery and conventional groups regarding incidence of membrane perforation, duration, and operation site visibility as well as patient's expectation before and experience after the operation (P > 0.05). However, there were significantly more pain and swelling in the conventional group compared with the Piezosurgery group (P ≤ 0.05). Sinus lifting procedure performed with Piezosurgery causes less pain and swelling postoperatively compared with conventional technique. Patients' daily life activities and experience about the operation are not affected from the surgical technique.
Computer-Aided Diagnosis of Acute Lymphoblastic Leukaemia
2018-01-01
Leukaemia is a form of blood cancer which affects the white blood cells and damages the bone marrow. Usually complete blood count (CBC) and bone marrow aspiration are used to diagnose the acute lymphoblastic leukaemia. It can be a fatal disease if not diagnosed at the earlier stage. In practice, manual microscopic evaluation of stained sample slide is used for diagnosis of leukaemia. But manual diagnostic methods are time-consuming, less accurate, and prone to errors due to various human factors like stress, fatigue, and so forth. Therefore, different automated systems have been proposed to wrestle the glitches in the manual diagnostic methods. In recent past, some computer-aided leukaemia diagnosis methods are presented. These automated systems are fast, reliable, and accurate as compared to manual diagnosis methods. This paper presents review of computer-aided diagnosis systems regarding their methodologies that include enhancement, segmentation, feature extraction, classification, and accuracy. PMID:29681996
Islam, Asef; Oldham, Michael J; Wexler, Anthony S
2017-11-01
Mammalian lungs are comprised of large numbers of tracheobronchial airways that transition from the trachea to alveoli. Studies as wide ranging as pollutant deposition and lung development rely on accurate characterization of these airways. Advancements in CT imaging and the value of computational approaches in eliminating the burden of manual measurement are providing increased efficiency in obtaining this geometric data. In this study, we compare an automated method to a manual one for the first six generations of three Balb/c mouse lungs. We find good agreement between manual and automated methods and that much of the disagreement can be attributed to method precision. Using the automated method, we then provide anatomical data for the entire tracheobronchial airway tree from three Balb/C mice. Anat Rec, 2017. © 2017 Wiley Periodicals, Inc. Anat Rec, 300:2046-2057, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Somoskeöy, Szabolcs; Tunyogi-Csapó, Miklós; Bogyó, Csaba; Illés, Tamás
2012-11-01
Three-dimensional (3D) deformations of the spine are predominantly characterized by two-dimensional (2D) angulation measurements in coronal and sagittal planes, using anteroposterior and lateral X-ray images. For coronal curves, a method originally described by Cobb and for sagittal curves a modified Cobb method are most widely used in practice, and these methods have been shown to exhibit good-to-excellent reliability and reproducibility, carried out either manually or by computer-based tools. Recently, an ultralow radiation dose-integrated radioimaging solution was introduced with special software for realistic 3D visualization and parametric characterization of the spinal column. Comparison of accuracy, correlation of measurement values, intraobserver and interrater reliability of methods by conventional manual 2D and sterEOS 3D measurements in a routine clinical setting. Retrospective nonrandomized study of diagnostic X-ray images created as part of a routine clinical protocol of eligible patients examined at our clinic during a 30-month period between July 2007 and December 2009. In total, 201 individuals (170 females, 31 males; mean age, 19.88 years) including 10 healthy athletes with normal spine and patients with adolescent idiopathic scoliosis (175 cases), adult degenerative scoliosis (11 cases), and Scheuermann hyperkyphosis (5 cases). Overall range of coronal curves was between 2.4° and 117.5°. Analysis of accuracy and reliability of measurements were carried out on a group of all patients and in subgroups based on coronal plane deviation: 0° to 10° (Group 1, n=36), 10° to 25° (Group 2, n=25), 25° to 50° (Group 3, n=69), 50° to 75° (Group 4, n=49), and more than 75° (Group 5, n=22). Coronal and sagittal curvature measurements were determined by three experienced examiners, using either traditional 2D methods or automatic measurements based on sterEOS 3D reconstructions. Manual measurements were performed three times, and sterEOS 3D reconstructions and automatic measurements were performed two times by each examiner. Means comparison t test, Pearson bivariate correlation analysis, reliability analysis by intraclass correlation coefficients for intraobserver reproducibility and interrater reliability were performed using SPSS v16.0 software (IBM Corp., Armonk, NY, USA). No funds were received in support of this work. No benefits in any form have been or will be received from a commercial party related directly or indirectly to the subject of this article. In comparison with manual 2D methods, only small and nonsignificant differences were detectable in sterEOS 3D-based curvature data. Intraobserver reliability was excellent for both methods, and interrater reproducibility was consistently higher for sterEOS 3D methods that was found to be unaffected by the magnitude of coronal curves or sagittal plane deviations. This is the first clinical report on EOS 2D/3D system (EOS Imaging, Paris, France) and its sterEOS 3D software, documenting an excellent capability for accurate, reliable, and reproducible spinal curvature measurements. Copyright © 2012 Elsevier Inc. All rights reserved.
Methods for the Determination of Chemical Contaminants in Drinking Water. Training Manual.
ERIC Educational Resources Information Center
Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.
This training manual, intended for chemists and technicians with little or no experience in chemical procedures required to monitor drinking water, covers analytical methods for inorganic and organic chemical contaminants listed in the interim primary drinking water regulations. Topics include methods for heavy metals, nitrate, and organic…
Illustrated surface mining methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1979-01-01
This manual provides a visual synopsis of surface coal mining methods in the United States. The manual presents various surface mining methods and techniques through artist renderings and appropriate descriptions. The productive coal fields of the United States were divided into four regions according to geology and physiography. A glossay of terminology is included. (DP)
Analytical Methods for Trace Metals. Training Manual.
ERIC Educational Resources Information Center
Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.
This training manual presents material on the theoretical concepts involved in the methods listed in the Federal Register as approved for determination of trace metals. Emphasis is on laboratory operations. This course is intended for chemists and technicians with little or no experience in analytical methods for trace metals. Students should have…
Dialects for the Stage: A Manual and Two Casette Tapes.
ERIC Educational Resources Information Center
Machlin, Evangeline
This document contains a manual and two cassette tapes designed to help actors and actresses learn to speak various dialects. The tapes and the manual are arranged for the play-it-and-say-it method of dialect acquisition. The first three parts discuss the tapes and the manual in general, the dialect texts and dialect data, and the steps involved…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Inoue, Minoru; Yoshimura, Michio, E-mail: myossy@kuhp.kyoto-u.ac.jp; Sato, Sayaka
2015-04-15
Purpose: To investigate image-registration errors when using fiducial markers with a manual method and the point-based rigid-body registration (PRBR) algorithm in accelerated partial breast irradiation (APBI) patients, with accompanying fiducial deviations. Methods: Twenty-two consecutive patients were enrolled in a prospective trial examining 10-fraction APBI. Titanium clips were implanted intraoperatively around the seroma in all patients. For image-registration, the positions of the clips in daily kV x-ray images were matched to those in the planning digitally reconstructed radiographs. Fiducial and gravity registration errors (FREs and GREs, respectively), representing resulting misalignments of the edge and center of the target, respectively, were comparedmore » between the manual and algorithm-based methods. Results: In total, 218 fractions were evaluated. Although the mean FRE/GRE values for the manual and algorithm-based methods were within 3 mm (2.3/1.7 and 1.3/0.4 mm, respectively), the percentages of fractions where FRE/GRE exceeded 3 mm using the manual and algorithm-based methods were 18.8%/7.3% and 0%/0%, respectively. Manual registration resulted in 18.6% of patients with fractions of FRE/GRE exceeding 5 mm. The patients with larger clip deviation had significantly more fractions showing large FRE/GRE using manual registration. Conclusions: For image-registration using fiducial markers in APBI, the manual registration results in more fractions with considerable registration error due to loss of fiducial objectivity resulting from their deviation. The authors recommend the PRBR algorithm as a safe and effective strategy for accurate, image-guided registration and PTV margin reduction.« less
Zhu, Chengcheng; Patterson, Andrew J; Thomas, Owen M; Sadat, Umar; Graves, Martin J; Gillard, Jonathan H
2013-04-01
Luminal stenosis is used for selecting the optimal management strategy for patients with carotid artery disease. The aim of this study is to evaluate the reproducibility of carotid stenosis quantification using manual and automated segmentation methods using submillimeter through-plane resolution Multi-Detector CT angiography (MDCTA). 35 patients having carotid artery disease with >30 % luminal stenosis as identified by carotid duplex imaging underwent contrast enhanced MDCTA. Two experienced CT readers quantified carotid stenosis from axial source images, reconstructed maximum intensity projection (MIP) and 3D-carotid geometry which was automatically segmented by an open-source toolkit (Vascular Modelling Toolkit, VMTK) using NASCET criteria. Good agreement among the measurement using axial images, MIP and automatic segmentation was observed. Automatic segmentation methods show better inter-observer agreement between the readers (intra-class correlation coefficient (ICC): 0.99 for diameter stenosis measurement) than manual measurement of axial (ICC = 0.82) and MIP (ICC = 0.86) images. Carotid stenosis quantification using an automatic segmentation method has higher reproducibility compared with manual methods.
Precipitate statistics in an Al-Mg-Si-Cu alloy from scanning precession electron diffraction data
NASA Astrophysics Data System (ADS)
Sunde, J. K.; Paulsen, Ø.; Wenner, S.; Holmestad, R.
2017-09-01
The key microstructural feature providing strength to age-hardenable Al alloys is nanoscale precipitates. Alloy development requires a reliable statistical assessment of these precipitates, in order to link the microstructure with material properties. Here, it is demonstrated that scanning precession electron diffraction combined with computational analysis enable the semi-automated extraction of precipitate statistics in an Al-Mg-Si-Cu alloy. Among the main findings is the precipitate number density, which agrees well with a conventional method based on manual counting and measurements. By virtue of its data analysis objectivity, our methodology is therefore seen as an advantageous alternative to existing routines, offering reproducibility and efficiency in alloy statistics. Additional results include improved qualitative information on phase distributions. The developed procedure is generic and applicable to any material containing nanoscale precipitates.
ANSI/ASHRAE/IES Standard 90.1-2010 Performance Rating Method Reference Manual
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goel, Supriya; Rosenberg, Michael I.
This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1- 2010 (Standard 90.1-2010).The PRM is used for rating the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM. It should be noted that this document is created independently from ASHRAE and SSPC 90.1 and is not sanctioned nor approved by either ofmore » those entities . Potential users of this manual include energy modelers, software developers and implementers of “beyond code” energy programs. Energy modelers using ASHRAE Standard 90.1-2010 for beyond code programs can use this document as a reference manual for interpreting requirements of the Performance Rating method. Software developers, developing tools for automated creation of the baseline model can use this reference manual as a guideline for developing the rules for the baseline model.« less
LOCALIZING THE RANGELAND HEALTH METHOD FOR SOUTHEASTERN ARIZONA
The interagency manual Interpreting Indicators of Rangeland Health, Version 4 (Technical Reference 1734-6) provides a method for making rangeland health assessments. The manual recommends that the rangeland health assessment approach be adapted to local conditions. This technica...
Thellier GUI: An integrated tool for analyzing paleointensity data from Thellier-type experiments
NASA Astrophysics Data System (ADS)
Shaar, Ron; Tauxe, Lisa
2013-03-01
Thellier-type experiments are a method used to estimate the intensity of the ancient geomagnetic field from samples carrying thermoremanent magnetization. The analysis of Thellier-type experimental data is conventionally done by manually interpreting data from each specimen individually. The main limitations of this approach are: (1) manual interpretation is highly subjective and can be biased by misleading concepts, (2) the procedure is time consuming, and (3) unless the measurement data are published, the final results cannot be reproduced by readers. These issues compound when trying to combine together paleointensity data from a collection of studies. Here, we address these problems by introducing the Thellier GUI: a comprehensive tool for interpreting Thellier-type experimental data. The tool presents a graphical user interface, which allows manual interpretation of the data, but also includes two new interpretation tools: (1) Thellier Auto Interpreter: an automatic interpretation procedure based on a given set of experimental requirements, and 2) Consistency Test: a self-test for the consistency of the results assuming groups of samples that should have the same paleointensity values. We apply the new tools to data from two case studies. These demonstrate that interpretation of non-ideal Arai plots is nonunique and different selection criteria can lead to significantly different conclusions. Hence, we recommend adopting the automatic interpretation approach, as it allows a more objective interpretation, which can be easily repeated or revised by others. When the analysis is combined with a Consistency Test, the credibility of the interpretations is enhanced. We also make the case that published paleointensity studies should include the measurement data (as supplementary files or as a contributions to the MagIC database) so that results based on a particular data set can be reproduced and assessed by others.
Use of the smartphone for end vertebra selection in scoliosis.
Pepe, Murad; Kocadal, Onur; Iyigun, Abdullah; Gunes, Zafer; Aksahin, Ertugrul; Aktekin, Cem Nuri
2017-03-01
The aim of our study was to develop a smartphone-aided end vertebra selection method and to investigate its effectiveness in Cobb angle measurement. Twenty-nine adolescent idiopathic scoliosis patients' pre-operative posteroanterior scoliosis radiographs were used for end vertebra selection and Cobb angle measurement by standard method and smartphone-aided method. Measurements were performed by 7 examiners. The intraclass correlation coefficient was used to analyze selection and measurement reliability. Summary statistics of variance calculations were used to provide 95% prediction limits for the error in Cobb angle measurements. A paired 2-tailed t test was used to analyze end vertebra selection differences. Mean absolute Cobb angle difference was 3.6° for the manual method and 1.9° for the smartphone-aided method. Both intraobserver and interobserver reliability were found excellent in manual and smartphone set for Cobb angle measurement. Both intraobserver and interobserver reliability were found excellent in manual and smartphone set for end vertebra selection. But reliability values of manual set were lower than smartphone. Two observers selected significantly different end vertebra in their repeated selections for manual method. Smartphone-aided method for end vertebra selection and Cobb angle measurement showed excellent reliability. We can expect a reduction in measurement error rates with the widespread use of this method in clinical practice. Level III, Diagnostic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.
Diffuse intrinsic pontine glioma: is MRI surveillance improved by region of interest volumetry?
Riley, Garan T; Armitage, Paul A; Batty, Ruth; Griffiths, Paul D; Lee, Vicki; McMullan, John; Connolly, Daniel J A
2015-02-01
Paediatric diffuse intrinsic pontine glioma (DIPG) is noteworthy for its fibrillary infiltration through neuroparenchyma and its resultant irregular shape. Conventional volumetry methods aim to approximate such irregular tumours to a regular ellipse, which could be less accurate when assessing treatment response on surveillance MRI. Region-of-interest (ROI) volumetry methods, using manually traced tumour profiles on contiguous imaging slices and subsequent computer-aided calculations, may prove more reliable. To evaluate whether the reliability of MRI surveillance of DIPGs can be improved by the use of ROI-based volumetry. We investigated the use of ROI- and ellipsoid-based methods of volumetry for paediatric DIPGs in a retrospective review of 22 MRI examinations. We assessed the inter- and intraobserver variability of the two methods when performed by four observers. ROI- and ellipsoid-based methods strongly correlated for all four observers. The ROI-based volumes showed slightly better agreement both between and within observers than the ellipsoid-based volumes (inter-[intra-]observer agreement 89.8% [92.3%] and 83.1% [88.2%], respectively). Bland-Altman plots show tighter limits of agreement for the ROI-based method. Both methods are reproducible and transferrable among observers. ROI-based volumetry appears to perform better with greater intra- and interobserver agreement for complex-shaped DIPG.
2011-01-01
Background Global positioning systems (GPS) are increasingly being used in health research to determine the location of study participants. Combining GPS data with data collected via travel/activity diaries allows researchers to assess where people travel in conjunction with data about trip purpose and accompaniment. However, linking GPS and diary data is problematic and to date the only method has been to match the two datasets manually, which is time consuming and unlikely to be practical for larger data sets. This paper assesses the feasibility of a new sequence alignment method of linking GPS and travel diary data in comparison with the manual matching method. Methods GPS and travel diary data obtained from a study of children's independent mobility were linked using sequence alignment algorithms to test the proof of concept. Travel diaries were assessed for quality by counting the number of errors and inconsistencies in each participant's set of diaries. The success of the sequence alignment method was compared for higher versus lower quality travel diaries, and for accompanied versus unaccompanied trips. Time taken and percentage of trips matched were compared for the sequence alignment method and the manual method. Results The sequence alignment method matched 61.9% of all trips. Higher quality travel diaries were associated with higher match rates in both the sequence alignment and manual matching methods. The sequence alignment method performed almost as well as the manual method and was an order of magnitude faster. However, the sequence alignment method was less successful at fully matching trips and at matching unaccompanied trips. Conclusions Sequence alignment is a promising method of linking GPS and travel diary data in large population datasets, especially if limitations in the trip detection algorithm are addressed. PMID:22142322
Xiong, Hui; Sultan, Laith R; Cary, Theodore W; Schultz, Susan M; Bouzghar, Ghizlane; Sehgal, Chandra M
2017-05-01
To assess the diagnostic performance of a leak-plugging segmentation method that we have developed for delineating breast masses on ultrasound images. Fifty-two biopsy-proven breast lesion images were analyzed by three observers using the leak-plugging and manual segmentation methods. From each segmentation method, grayscale and morphological features were extracted and classified as malignant or benign by logistic regression analysis. The performance of leak-plugging and manual segmentations was compared by: size of the lesion, overlap area ( O a ) between the margins, and area under the ROC curves ( A z ). The lesion size from leak-plugging segmentation correlated closely with that from manual tracing ( R 2 of 0.91). O a was higher for leak plugging, 0.92 ± 0.01 and 0.86 ± 0.06 for benign and malignant masses, respectively, compared to 0.80 ± 0.04 and 0.73 ± 0.02 for manual tracings. Overall O a between leak-plugging and manual segmentations was 0.79 ± 0.14 for benign and 0.73 ± 0.14 for malignant lesions. A z for leak plugging was consistently higher (0.910 ± 0.003) compared to 0.888 ± 0.012 for manual tracings. The coefficient of variation of A z between three observers was 0.29% for leak plugging compared to 1.3% for manual tracings. The diagnostic performance, size measurements, and observer variability for automated leak-plugging segmentations were either comparable to or better than those of manual tracings.
Feature ranking and rank aggregation for automatic sleep stage classification: a comparative study.
Najdi, Shirin; Gharbali, Ali Abdollahi; Fonseca, José Manuel
2017-08-18
Nowadays, sleep quality is one of the most important measures of healthy life, especially considering the huge number of sleep-related disorders. Identifying sleep stages using polysomnographic (PSG) signals is the traditional way of assessing sleep quality. However, the manual process of sleep stage classification is time-consuming, subjective and costly. Therefore, in order to improve the accuracy and efficiency of the sleep stage classification, researchers have been trying to develop automatic classification algorithms. Automatic sleep stage classification mainly consists of three steps: pre-processing, feature extraction and classification. Since classification accuracy is deeply affected by the extracted features, a poor feature vector will adversely affect the classifier and eventually lead to low classification accuracy. Therefore, special attention should be given to the feature extraction and selection process. In this paper the performance of seven feature selection methods, as well as two feature rank aggregation methods, were compared. Pz-Oz EEG, horizontal EOG and submental chin EMG recordings of 22 healthy males and females were used. A comprehensive feature set including 49 features was extracted from these recordings. The extracted features are among the most common and effective features used in sleep stage classification from temporal, spectral, entropy-based and nonlinear categories. The feature selection methods were evaluated and compared using three criteria: classification accuracy, stability, and similarity. Simulation results show that MRMR-MID achieves the highest classification performance while Fisher method provides the most stable ranking. In our simulations, the performance of the aggregation methods was in the average level, although they are known to generate more stable results and better accuracy. The Borda and RRA rank aggregation methods could not outperform significantly the conventional feature ranking methods. Among conventional methods, some of them slightly performed better than others, although the choice of a suitable technique is dependent on the computational complexity and accuracy requirements of the user.
Boers, A M; Marquering, H A; Jochem, J J; Besselink, N J; Berkhemer, O A; van der Lugt, A; Beenen, L F; Majoie, C B
2013-08-01
Cerebral infarct volume as observed in follow-up CT is an important radiologic outcome measure of the effectiveness of treatment of patients with acute ischemic stroke. However, manual measurement of CIV is time-consuming and operator-dependent. The purpose of this study was to develop and evaluate a robust automated measurement of the CIV. The CIV in early follow-up CT images of 34 consecutive patients with acute ischemic stroke was segmented with an automated intensity-based region-growing algorithm, which includes partial volume effect correction near the skull, midline determination, and ventricle and hemorrhage exclusion. Two observers manually delineated the CIV. Interobserver variability of the manual assessments and the accuracy of the automated method were evaluated by using the Pearson correlation, Bland-Altman analysis, and Dice coefficients. The accuracy was defined as the correlation with the manual assessment as a reference standard. The Pearson correlation for the automated method compared with the reference standard was similar to the manual correlation (R = 0.98). The accuracy of the automated method was excellent with a mean difference of 0.5 mL with limits of agreement of -38.0-39.1 mL, which were more consistent than the interobserver variability of the 2 observers (-40.9-44.1 mL). However, the Dice coefficients were higher for the manual delineation. The automated method showed a strong correlation and accuracy with the manual reference measurement. This approach has the potential to become the standard in assessing the infarct volume as a secondary outcome measure for evaluating the effectiveness of treatment.
Koehl, Bérengère; Missud, Florence; Holvoet, Laurent; Ithier, Ghislaine; Sakalian-Black, Oliver; Haouari, Zinedine; Lesprit, Emmanuelle; Baruchel, André; Benkerrou, Malika
2017-03-14
Children with sickle cell anemia (SCA) may be at risk of cerebral vasculopathy and strokes, which can be prevented by chronic transfusion programs. Repeated transfusions of packed red blood cells (PRBCs) is currently the simplest and most used technique for chronic transfusion programs. However, iron overload is one of the major side effects of this therapy. More developed methods exist, notably the apheresis of RBC (erythrapheresis), which is currently the safest and most efficient method. However, it is costly, complicated, and cannot be implemented everywhere, nor is it suitable for all patients. Manual exchange transfusions combine one or more manual phlebotomies with a PRBC transfusion. At the Reference Center of Sickle Cell Disease, we set up a continuous method of manual exchange transfusion that is feasible for all hospital settings, demands no specific equipment, and is widely applicable. In terms of HbS decrease, stroke prevention, and iron overload prevention, this method showed comparable efficiency to erythrapheresis. In cases where erythrapheresis is not available, this method can be a good alternative for patients and care centers.
Turley, James P; Johnson, Todd R; Smith, Danielle Paige; Zhang, Jaijie; Brixey, Juliana J
2006-04-01
Use of medical devices often directly contributes to medical errors. Because it is difficult or impossible to change the design of existing devices, the best opportunity for improving medical device safety is during the purchasing process. However, most hospital personnel are not familiar with the usability evaluation methods designed to identify aspects of a user interface that do not support intuitive and safe use. A review of medical device operating manuals is proposed as a more practical method of usability evaluation. Operating manuals for five volumetric infusion pumps from three manufacturers were selected for this study (January-April 2003). Each manual's safety message content was evaluated to determine whether the message indicated a device design characteristic that violated known usability principles (heuristics) or indicated a violation of an affordance of the device. "Minimize memory load," with 65 violations, was the heuristic violated most frequently across pumps. Variations between pumps, including the frequency and severity of violations for each, were noted. Results suggest that manual review can provide a proxy for heuristic evaluation of the actual medical device. This method, intended to be a component of prepurchasing evaluation, can complement more formal usability evaluation methods and be used to select a subset of devices for more extensive and formal testing.
Wang, Ling-jia; Kissler, Hermann J; Wang, Xiaojun; Cochet, Olivia; Krzystyniak, Adam; Misawa, Ryosuke; Golab, Karolina; Tibudan, Martin; Grzanka, Jakub; Savari, Omid; Grose, Randall; Kaufman, Dixon B; Millis, Michael; Witkowski, Piotr
2015-01-01
Pancreatic islet mass, represented by islet equivalent (IEQ), is the most important parameter in decision making for clinical islet transplantation. To obtain IEQ, the sample of islets is routinely counted manually under a microscope and discarded thereafter. Islet purity, another parameter in islet processing, is routinely acquired by estimation only. In this study, we validated our digital image analysis (DIA) system developed using the software of Image Pro Plus for islet mass and purity assessment. Application of the DIA allows to better comply with current good manufacturing practice (cGMP) standards. Human islet samples were captured as calibrated digital images for the permanent record. Five trained technicians participated in determination of IEQ and purity by manual counting method and DIA. IEQ count showed statistically significant correlations between the manual method and DIA in all sample comparisons (r >0.819 and p < 0.0001). Statistically significant difference in IEQ between both methods was found only in High purity 100μL sample group (p = 0.029). As far as purity determination, statistically significant differences between manual assessment and DIA measurement was found in High and Low purity 100μL samples (p<0.005), In addition, islet particle number (IPN) and the IEQ/IPN ratio did not differ statistically between manual counting method and DIA. In conclusion, the DIA used in this study is a reliable technique in determination of IEQ and purity. Islet sample preserved as a digital image and results produced by DIA can be permanently stored for verification, technical training and islet information exchange between different islet centers. Therefore, DIA complies better with cGMP requirements than the manual counting method. We propose DIA as a quality control tool to supplement the established standard manual method for islets counting and purity estimation. PMID:24806436
Battery Test Manual For Plug-In Hybrid Electric Vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeffrey R. Belt
2010-09-01
This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Program. It is based on technical targets established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of some of the proceduresmore » and supporting analysis, a revision including some modifications and clarifications of these procedures is expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices.« less
Battery Test Manual For Plug-In Hybrid Electric Vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeffrey R. Belt
2010-12-01
This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Program. It is based on technical targets established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of some of the proceduresmore » and supporting analysis, a revision including some modifications and clarifications of these procedures is expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices.« less
Three-dimensional murine airway segmentation in micro-CT images
NASA Astrophysics Data System (ADS)
Shi, Lijun; Thiesse, Jacqueline; McLennan, Geoffrey; Hoffman, Eric A.; Reinhardt, Joseph M.
2007-03-01
Thoracic imaging for small animals has emerged as an important tool for monitoring pulmonary disease progression and therapy response in genetically engineered animals. Micro-CT is becoming the standard thoracic imaging modality in small animal imaging because it can produce high-resolution images of the lung parenchyma, vasculature, and airways. Segmentation, measurement, and visualization of the airway tree is an important step in pulmonary image analysis. However, manual analysis of the airway tree in micro-CT images can be extremely time-consuming since a typical dataset is usually on the order of several gigabytes in size. Automated and semi-automated tools for micro-CT airway analysis are desirable. In this paper, we propose an automatic airway segmentation method for in vivo micro-CT images of the murine lung and validate our method by comparing the automatic results to manual tracing. Our method is based primarily on grayscale morphology. The results show good visual matches between manually segmented and automatically segmented trees. The average true positive volume fraction compared to manual analysis is 91.61%. The overall runtime for the automatic method is on the order of 30 minutes per volume compared to several hours to a few days for manual analysis.
Korczyński, P; Górska, K; Nasiłowski, J; Chazan, R; Krenke, R
2015-01-01
Beside standard chest tube drainage other less invasive techniques have been used in the management of patients with an acute episode of spontaneous pneumothorax. The aim of the study was to evaluate the short term effect of spontaneous pneumothorax treatment with small-bore pleural catheter and manual aspiration as compared to large-bore chest tube drainage. Patients with an episode of pneumothorax who required pleural intervention were enrolled in the study and randomly assigned to one of the treatment arms: (1) small-bore pleural catheter (8 Fr) with manual aspiration; (2) standard chest tube drainage (20-24 Fr). Success rate of the first line treatment, duration of catheter or chest tube drainage, and the need for surgical intervention were the outcome measures. The study group included 49 patients (mean age 46.9±21.3 years); with 22 and 27 allocated to small bore manual aspiration and chest tube drainage groups, respectively. There were no significant differences in the baseline characteristics of patients in both therapeutic arms. First line treatment success rates were 64% and 82% in the manual aspiration and chest tube drainage groups, respectively; the difference was insignificant. Median time of treatment with small bore catheter was significantly shorter than conventional chest tube drainage (2.0 vs. 6.0 days; p<0.05). Our results show that treatment of spontaneous pneumothorax with small-bore pleural catheter and manual aspiration might be similarly effective as is chest tube drainage in terms of immediate lung re-expansion.
Initial development of a device for controlling manually applied forces.
Waddington, Gordon S; Adams, Roger D
2007-05-01
In both simulation and manual therapy studies, substantial variability has been shown when therapists attempt to replicate an applied force. Knowledge about the forces employed during treatment could reduce this variability. In the current project, a prototype for a mobilizing device incorporating a dynamometer was constructed. The prototype device was built around a conventional "hand-grip" dynamometer to give dial visibility during application of mobilizing forces and a moulded handle was used to increase the hand contact surface during force application. The variability of the mobilization forces produced was measured, and ratings of comfort during a simulated spinal mobilization technique were obtained from therapists. Thirty physiotherapists were randomly allocated to apply either: (i) their own estimate of a grade III mobilization force using their hands in a pisiform grip or (ii) a 100N force with the manual therapy dynamometer, and to rate comfort during the performance of both techniques on a 100mm visual analogue scale. Variance in dynamometer-dial-guided force application was always significantly less than the variance in therapist-concept-guided force application. Repeated-measures tests showed that the mean force produced at grade III was not significantly different from 100N, but physiotherapist comfort ratings were found to be significantly greater (P<0.01) when the manual therapy dynamometer was used. Manually applied force variability was significantly less and therapist comfort greater when using a device with visual access to a dial giving immediate force readout.
An algorithm for pavement crack detection based on multiscale space
NASA Astrophysics Data System (ADS)
Liu, Xiang-long; Li, Qing-quan
2006-10-01
Conventional human-visual and manual field pavement crack detection method and approaches are very costly, time-consuming, dangerous, labor-intensive and subjective. They possess various drawbacks such as having a high degree of variability of the measure results, being unable to provide meaningful quantitative information and almost always leading to inconsistencies in crack details over space and across evaluation, and with long-periodic measurement. With the development of the public transportation and the growth of the Material Flow System, the conventional method can far from meet the demands of it, thereby, the automatic pavement state data gathering and data analyzing system come to the focus of the vocation's attention, and developments in computer technology, digital image acquisition, image processing and multi-sensors technology made the system possible, but the complexity of the image processing always made the data processing and data analyzing come to the bottle-neck of the whole system. According to the above description, a robust and high-efficient parallel pavement crack detection algorithm based on Multi-Scale Space is proposed in this paper. The proposed method is based on the facts that: (1) the crack pixels in pavement images are darker than their surroundings and continuous; (2) the threshold values of gray-level pavement images are strongly related with the mean value and standard deviation of the pixel-grey intensities. The Multi-Scale Space method is used to improve the data processing speed and minimize the effectiveness caused by image noise. Experiment results demonstrate that the advantages are remarkable: (1) it can correctly discover tiny cracks, even from very noise pavement image; (2) the efficiency and accuracy of the proposed algorithm are superior; (3) its application-dependent nature can simplify the design of the entire system.
Acupuncture for melasma in women: a systematic review of randomised controlled trials.
Chai, Qianyun; Fei, Yutong; Cao, Huijuan; Wang, Congcong; Tian, Jinzhou; Liu, Jianping
2015-08-01
Melasma is a common facial skin disorder seen in women. Manual acupuncture (MA) is widely used alone or in combination with conventional treatments for melasma in China. To assess the effectiveness and safety of MA for melasma, and explore the range of treatments applied. Six databases were searched systematically for randomised controlled trials (RCTs) on acupuncture for melasma in women up to November 2014. RevMan software was used for data analysis. The Cochrane tool of Risk of Bias was used to assess the methodological quality of the RCTs. Eight RCTs involving 587 women were included. Seven studies used the encircling needling method, four studies used the quick needling method and four studies used intensive needle manipulations. Five studies provided individualised acupuncture treatments. Points used with highest frequency were SP6, ST36 and SP10. MA was compared with oral tranexamic acid, vitamin C and E, vitamin C and tamoxifen, topical 20% azelaic acid, hydroquinone, vitamin A and no treatment. Studies were too heterogeneous to conduct a meta-analysis. For global outcome measures, seven trials showed that MA groups were significantly better than the conventional treatments either with a better cure rate or with a better combined cure rate and markedly effective rate, and one trial did not (MA vs vitamin A). No acupuncture-related adverse events were reported. MA appeared to be beneficial and safe for women with melasma, but insufficient evidence was found to reach conclusions. The encircling needling method, the quick needling method, intensive needle manipulations and individualised points' selection were widely used. Well-designed trials are required. PROSPERO Systematic review registration: CRD42013006396. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
NASA Astrophysics Data System (ADS)
Mazonakis, Michalis; Grinias, Elias; Pagonidis, Konstantin; Tziritas, George; Damilakis, John
2010-02-01
The purpose of this study was to develop and evaluate a semiautomatic method for left ventricular (LV) segmentation on cine MR images and subsequent estimation of cardiac parameters. The study group comprised cardiac MR examinations of 18 consecutive patients with known or suspected coronary artery disease. The new method allowed the automatic detection of the LV endocardial and epicardial boundaries on each short-axis cine MR image using a Bayesian flooding segmentation algorithm and weighted least-squares B-splines minimization. Manual editing of the automatic contours could be performed for unsatisfactory segmentation results. The end-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF) and LV mass estimated by the new method were compared with the reference values obtained by manually tracing the LV cavity borders. The reproducibility of the new method was determined using data from two independent observers. The mean number of endocardial and epicardial outlines not requiring any manual adjustment was more than 80% and 76% of the total contour number per study, respectively. The mean segmentation time including the required manual corrections was 2.3 ± 0.7 min per patient. LV volumes estimated by the semiautomatic method were significantly lower than those by manual tracing (P < 0.05), whereas no difference was found for EF and LV mass (P > 0.05). LV indices estimated by the two methods were well correlated (r >= 0.80). The mean difference between manual and semiautomatic method for estimating EDV, ESV, EF and LV mass was 6.1 ± 7.2 ml, 3.0 ± 5.2 ml, -0.6 ± 4.3% and -6.2 ± 12.2 g, respectively. The intraobserver and interobserver variability associated with the semiautomatic determination of LV indices was 0.5-1.2% and 0.8-3.9%, respectively. The estimation of LV parameters with the new semiautomatic segmentation method is technically feasible, highly reproducible and time effective.
ERIC Educational Resources Information Center
Dawson, George G.; Prehn, Edward C.
The primary purpose of this book is to point out events reported in the typical U.S. history course that can be enriched by a consideration of relevant economic topics. The book is organized chronologically by 21 topics: explorers and the early American colonies; the American Revolution; the Confederation period and the Constitutional Convention;…
Holographic deep learning for rapid optical screening of anthrax spores
Jo, YoungJu; Park, Sangjin; Jung, JaeHwang; Yoon, Jonghee; Joo, Hosung; Kim, Min-hyeok; Kang, Suk-Jo; Choi, Myung Chul; Lee, Sang Yup; Park, YongKeun
2017-01-01
Establishing early warning systems for anthrax attacks is crucial in biodefense. Despite numerous studies for decades, the limited sensitivity of conventional biochemical methods essentially requires preprocessing steps and thus has limitations to be used in realistic settings of biological warfare. We present an optical method for rapid and label-free screening of Bacillus anthracis spores through the synergistic application of holographic microscopy and deep learning. A deep convolutional neural network is designed to classify holographic images of unlabeled living cells. After training, the network outperforms previous techniques in all accuracy measures, achieving single-spore sensitivity and subgenus specificity. The unique “representation learning” capability of deep learning enables direct training from raw images instead of manually extracted features. The method automatically recognizes key biological traits encoded in the images and exploits them as fingerprints. This remarkable learning ability makes the proposed method readily applicable to classifying various single cells in addition to B. anthracis, as demonstrated for the diagnosis of Listeria monocytogenes, without any modification. We believe that our strategy will make holographic microscopy more accessible to medical doctors and biomedical scientists for easy, rapid, and accurate point-of-care diagnosis of pathogens. PMID:28798957
Advances in clinical studies of cardiopulmonary resuscitation
Chen, Shou-quan
2015-01-01
BACKGROUND: The survival rate of patients after cardiac arrest (CA) remains lower since 2010 International Consensus on Cardiopulmonary Resuscitation (CPR) and Emergency Cardiovascular Care (ECC) was published. In clinical trials, the methods and techniques for CPR have been overly described. This article gives an overview of the progress in methods and techniques for CPR in the past years. DATA SOURCES: Original articles about cardiac arrest and CPR from MEDLINE (PubMed) and relevant journals were searched, and most of them were clinical randomized controlled trials (RCTs). RESULTS: Forty-two articles on methods and techniques of CPR were reviewed, including chest compression and conventional CPR, chest compression depth and speed, defibrillation strategies and priority, mechanical and manual chest compression, advanced airway management, impedance threshold device (ITD) and active compression-decompression (ACD) CPR, epinephrine use, and therapeutic hypothermia. The results of studies and related issues described in the international guidelines had been testified. CONCLUSIONS: Although large multicenter studies on CPR are still difficult to carry out, progress has been made in the past 4 years in the methods and techniques of CPR. The results of this review provide evidences for updating the 2015 international guidelines. PMID:26056537
Svetnik, Vladimir; Ma, Junshui; Soper, Keith A.; Doran, Scott; Renger, John J.; Deacon, Steve; Koblan, Ken S.
2007-01-01
Objective: To evaluate the performance of 2 automated systems, Morpheus and Somnolyzer24X7, with various levels of human review/editing, in scoring polysomnographic (PSG) recordings from a clinical trial using zolpidem in a model of transient insomnia. Methods: 164 all-night PSG recordings from 82 subjects collected during 2 nights of sleep, one under placebo and one under zolpidem (10 mg) treatment were used. For each recording, 6 different methods were used to provide sleep stage scores based on Rechtschaffen & Kales criteria: 1) full manual scoring, 2) automated scoring by Morpheus 3) automated scoring by Somnolyzer24X7, 4) automated scoring by Morpheus with full manual review, 5) automated scoring by Morpheus with partial manual review, 6) automated scoring by Somnolyzer24X7 with partial manual review. Ten traditional clinical efficacy measures of sleep initiation, maintenance, and architecture were calculated. Results: Pair-wise epoch-by-epoch agreements between fully automated and manual scores were in the range of intersite manual scoring agreements reported in the literature (70%-72%). Pair-wise epoch-by-epoch agreements between automated scores manually reviewed were higher (73%-76%). The direction and statistical significance of treatment effect sizes using traditional efficacy endpoints were essentially the same whichever method was used. As the degree of manual review increased, the magnitude of the effect size approached those estimated with fully manual scoring. Conclusion: Automated or semi-automated sleep PSG scoring offers valuable alternatives to costly, time consuming, and intrasite and intersite variable manual scoring, especially in large multicenter clinical trials. Reduction in scoring variability may also reduce the sample size of a clinical trial. Citation: Svetnik V; Ma J; Soper KA; Doran S; Renger JJ; Deacon S; Koblan KS. Evaluation of automated and semi-automated scoring of polysomnographic recordings from a clinical trial using zolpidem in the treatment of insomnia. SLEEP 2007;30(11):1562-1574. PMID:18041489
An automatic method to calculate heart rate from zebrafish larval cardiac videos.
Kang, Chia-Pin; Tu, Hung-Chi; Fu, Tzu-Fun; Wu, Jhe-Ming; Chu, Po-Hsun; Chang, Darby Tien-Hao
2018-05-09
Zebrafish is a widely used model organism for studying heart development and cardiac-related pathogenesis. With the ability of surviving without a functional circulation at larval stages, strong genetic similarity between zebrafish and mammals, prolific reproduction and optically transparent embryos, zebrafish is powerful in modeling mammalian cardiac physiology and pathology as well as in large-scale high throughput screening. However, an economical and convenient tool for rapid evaluation of fish cardiac function is still in need. There have been several image analysis methods to assess cardiac functions in zebrafish embryos/larvae, but they are still improvable to reduce manual intervention in the entire process. This work developed a fully automatic method to calculate heart rate, an important parameter to analyze cardiac function, from videos. It contains several filters to identify the heart region, to reduce video noise and to calculate heart rates. The proposed method was evaluated with 32 zebrafish larval cardiac videos that were recording at three-day post-fertilization. The heart rate measured by the proposed method was comparable to that determined by manual counting. The experimental results show that the proposed method does not lose accuracy while largely reducing the labor cost and uncertainty of manual counting. With the proposed method, researchers do not have to manually select a region of interest before analyzing videos. Moreover, filters designed to reduce video noise can alleviate background fluctuations during the video recording stage (e.g. shifting), which makes recorders generate usable videos easily and therefore reduce manual efforts while recording.
1992-10-01
Manual CI APPENDIX D: Drawing Navigator Field Test D1 DISTRIBUTION Accesion For NTIS CRA&I OTIC TAB Unannouncea JustiteCdtOn By Distribution I "".i•I...methods replace manual methods, the automation will handle the data for the designer, thus reducing error and increasing throughput. However, the two...actively move data from one automation tool (CADD) to the other (the analysis program). This intervention involves a manual rekeying of data already in
Battery Test Manual For 48 Volt Mild Hybrid Electric Vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Lee Kenneth
2017-03-01
This manual details the U.S. Advanced Battery Consortium and U.S. Department of Energy Vehicle Technologies Program goals, test methods, and analysis techniques for a 48 Volt Mild Hybrid Electric Vehicle system. The test methods are outlined stating with characterization tests, followed by life tests. The final section details standardized analysis techniques for 48 V systems that allow for the comparison of different programs that use this manual. An example test plan is included, along with guidance to filling in gap table numbers.
ERIC Educational Resources Information Center
Puerto Rico State Dept. of Education, Hato Rey. Area for Vocational and Technical Education.
The three parts of this document are intended for a 3-semester course for pharmacy assistants. The course guide contains the following sections: occupational description; educational philosophy; general objectives; tasks/competencies for each unit; course organization; brief description of the topics; student standards; and evaluation methods.…
Automatic Organ Localization for Adaptive Radiation Therapy for Prostate Cancer
2005-05-01
and provides a framework for task 3. Key Research Accomplishments "* Comparison of manual segmentation with our automatic method, using several...well as manual segmentations by a different rater. "* Computation of the actual cumulative dose delivered to both the cancerous and critical healthy...adaptive treatment of prostate or other cancer. As a result, all such work must be done manually . However, manual segmentation of the tumor and neighboring
Boyle, M A; O'Donnell, M J; Russell, R J; Galvin, N; Swan, J; Coleman, D C
2015-10-01
Decontaminating dental chair unit (DCU) suction systems in a convenient, safe and effective manner is problematic. This study aimed to identify and quantify the extent of the problems using 25 DCUs, methodically eliminate these problems and develop an efficient approach for reliable, effective, automated disinfection. DCU suction system residual contamination by environmental and human-derived bacteria was evaluated by microbiological culture following standard aspiration disinfection with a quaternary ammonium disinfectant or alternatively, a novel flooding approach to disinfection. Disinfection of multicomponent suction handpieces, assembled and disassembled, was also studied. A prototype manual and a novel automated Suction Tube Cleaning System (STCS) were developed and tested, as were novel single component suction handpieces. Standard aspiration disinfection consistently failed to decontaminate DCU suction systems effectively. Semi-confluent bacterial growth (101-500 colony forming units (CFU) per culture plate) was recovered from up to 60% of suction filter housings and from up to 19% of high and 37% of low volume suction hoses. Manual and automated flood disinfection of DCU suction systems reduced this dramatically (ranges for filter cage and high and low volume hoses of 0-22, 0-16 and 0-14CFU/plate, respectively) (P<0.0001). Multicomponent suction handpieces could not be adequately disinfected without prior removal and disassembly. Novel single component handpieces, allowed their effective disinfection in situ using the STCS, which virtually eliminated contamination from the entire suction system. Flood disinfection of DCU suction systems and single component handpieces radically improves disinfection efficacy and considerably reduces potential cross-infection and cross-contamination risks. DCU suction systems become heavily contaminated during use. Conventional disinfection does not adequately control this. Furthermore, multicomponent suction handpieces cannot be adequately disinfected without disassembly, which is costly in time, staff and resources. The automated STCS DCU suction disinfection system used with single component handpieces provides an effective solution. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Said, Halima M; Krishnamani, Keshav; Omar, Shaheed V; Dreyer, Andries W; Sansom, Bianca; Fallows, Dorothy; Ismail, Nazir A
2016-10-01
The manual IS6110-based restriction fragment length polymorphism (RFLP) typing method is highly discriminatory; however, it is laborious and technically demanding, and data exchange remains a challenge. In an effort to improve IS6110-based RFLP to make it a faster format, DuPont Molecular Diagnostics recently introduced the IS6110-PvuII kit for semiautomated typing of Mycobacterium tuberculosis using the RiboPrinter microbial characterization system. This study aimed to evaluate the semiautomated RFLP typing against the standard manual method. A total of 112 isolates collected between 2013 and 2014 were included. All isolates were genotyped using manual and semiautomated RFLP typing methods. Clustering rates and discriminatory indexes were compared between methods. The overall performance of semiautomated RFLP compared to manual typing was excellent, with high discriminatory index (0.990 versus 0.995, respectively) and similar numbers of unique profiles (72 versus 74, respectively), numbers of clustered isolates (33 versus 31, respectively), cluster sizes (2 to 6 and 2 to 5 isolates, respectively), and clustering rates (21.9% and 17.1%, respectively). The semiautomated RFLP system is technically simple and significantly faster than the manual RFLP method (8 h versus 5 days). The analysis is fully automated and generates easily manageable databases of standardized fingerprints that can be easily exchanged between laboratories. Based on its high-throughput processing with minimal human effort, the semiautomated RFLP can be a very useful tool as a first-line method for routine typing of M. tuberculosis isolates, especially where Beijing strains are highly prevalent, followed by manual RFLP typing if resolution is not achieved, thereby saving time and labor. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Kaur, Indreshpal; Zulovich, Jane M; Gonzalez, Marissa; McGee, Kara M; Ponweera, Nirmali; Thandi, Daljit; Alvarez, Enrique F; Annandale, Kathy; Flagge, Frank; Rezvani, Katayoun; Shpall, Elizabeth
2017-03-01
Umbilical cord blood (CB) is being used as a source of hematopoietic stem cells (HSCs) and immune cells to treat many disorders. Because these cells are present in low numbers in CB, investigators have developed strategies to expand HSCs and other immune cells such as natural killer (NK) cells. The initial step in this process is to enrich mononuclear cells (MNCs) while depleting unwanted cells. The manual method of MNC enrichment is routinely used by many centers; however, it is an open system, time-consuming and operator dependent. For clinical manufacturing, it is important to have a closed system to avoid microbial contamination. In this study, we optimized an automated, closed system (Sepax) for enriching MNCs from cryopreserved CB units. Using Sepax, we observed higher recovery of total nucleated cells (TNC), CD34 + cells, NK cells and monocytes when compared to manual enrichment, despite similar TNC and CD34 + viability with the two methods. Even though the depletion of red blood cells, granulocytes and platelets was superior using the manual method, significantly higher CFU-GM were obtained in MNCs enriched using Sepax compared to the manual method. This is likely related to the fact that the automated Sepax significantly shortened the processing time (Sepax: 74 - 175 minutes versus manual method: 180 - 290 minutes). The use of DNAse and MgCl 2 during the Sepax thaw and wash procedure prevents clumping of cells and loss of viability, resulting in improved post-thaw cell recovery. We optimized enrichment of MNCs from cryopreserved CB products in a closed system using the Sepax which is a walk away and automated processing system. Copyright © 2017 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.
Manual stapedotomy still holds good in the era of laser.
Ganesan, Sivaraman; Anuprasad, S; Patra, Sisir Kumar; Parida, Pradipta Kumar; Gopalakrishnan, Suria; Verma, Nishikanta
2010-03-01
In the present era of stapedotomy, there is an inevitable role for laser. But the conventional technique with manual burr still has its own merits in various settings such as usage in resource poor setting in developing countries and avoidance of laser hazards. To evaluate the audiometric outcomes after manual stapedotomy. The present study was retrospective record-based study. Patients who have been diagnosed otosclerosis and those who were not willing for surgery with laser, but gave consent for manual stapedotomy were included for the study. Preoperatively, and at each subsequent post-operative follow-up visits, patients were required to undergo a pure-tone audiogram. The air-bone gaps at the end of 6 months were used for final analysis. Data was analyzed with using Statistical Package for Social Sciences (SPSS) version 12 (Chicago, IL, USA). Descriptive frequency distributions, mean, standard deviation of audiometric data were calculated. The paired t test was done to see the improvement in the air bone gap post-operatively. The mean age of presentation is 32.2 years. Overall, the male:female ratio was found to be 1:1.2. Post-operative air bone closure to 15 decibels was obtained in 80% of patients. There was no significant correlation between the pre-operative hearing loss and post-operative gain, age, and gender of distribution of focus. The post-operative hearing after stapedotomy has been remarkable in all the patients even with manual burr. There were no major vestibular complications in any of these patients. The study has shown that the significant post-operative hearing results can be still achieved with meticulous surgery by an experienced surgeon with manual burr in the present laser era.
Engineering analysis of shortfall for new technologies. Analysis memorandum
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1981-03-11
The engineering principles that govern the mpg performance of alternative technologies on the EPA test procedure and under in-use conditions are examined. The results can be used to interpret the shortfall of alternative technologies derived from statistical analyses. The analysis examines each of the four technologies in comparison to the conventional technology counterpart. Manual transmissions are compared to automatics, fuel injected S.I. engines to carburetted S.I. engines, front-wheel drive vehicles to rear-wheel drive vehicles and diesel engines to carburetted S.I. engines. The changes in shortfall of the four technologies in comparison to conventional technologies are explained through differences in responsesmore » to the factors.« less
Development of Handcraft Exercise Courses that Bring Out Student's Creativity
NASA Astrophysics Data System (ADS)
Senda, Shinkoh; Yamamoto, Koji; Fukumori, Tutom; Matsuura, Hideo; Sato, Kazuo
We have developed a new type of handcraft exercise program that aims to stimulate student's creativity on the way of design and fabrication of the subject machines. Conventional handicraft exercise program used to aim at letting students learn procedures of machining operation in accordance with a designated manual. Students having experienced our conventional exercise did not fully satisfied at those programs because of the lack in a room for their idea and creativity. Authors, a group of both technical and academic staffs, have developed and started the new type of program since 2003 at the Creation Plaza in Nagoya University. Developed program is classified into grades according to the difference in technical contents required for students.
Segmentation of breast ultrasound images based on active contours using neutrosophic theory.
Lotfollahi, Mahsa; Gity, Masoumeh; Ye, Jing Yong; Mahlooji Far, A
2018-04-01
Ultrasound imaging is an effective approach for diagnosing breast cancer, but it is highly operator-dependent. Recent advances in computer-aided diagnosis have suggested that it can assist physicians in diagnosis. Definition of the region of interest before computer analysis is still needed. Since manual outlining of the tumor contour is tedious and time-consuming for a physician, developing an automatic segmentation method is important for clinical application. The present paper represents a novel method to segment breast ultrasound images. It utilizes a combination of region-based active contour and neutrosophic theory to overcome the natural properties of ultrasound images including speckle noise and tissue-related textures. First, due to inherent speckle noise and low contrast of these images, we have utilized a non-local means filter and fuzzy logic method for denoising and image enhancement, respectively. This paper presents an improved weighted region-scalable active contour to segment breast ultrasound images using a new feature derived from neutrosophic theory. This method has been applied to 36 breast ultrasound images. It generates true-positive and false-positive results, and similarity of 95%, 6%, and 90%, respectively. The purposed method indicates clear advantages over other conventional methods of active contour segmentation, i.e., region-scalable fitting energy and weighted region-scalable fitting energy.
A fractal concentration area method for assigning a color palette for image representation
NASA Astrophysics Data System (ADS)
Cheng, Qiuming; Li, Qingmou
2002-05-01
Displaying the remotely sensed image with a proper color palette is the first task in any kind of image processing and pattern recognition in GIS and image processing environments. The purpose of displaying the image should be not only to provide a visual representation of the variance of the image, although this has been the primary objective of most conventional methods, but also the color palette should reflect real-world features on the ground which must be the primary objective of employing remotely sensed data. Although most conventional methods focus only on the first purpose of image representation, the concentration-area ( C- A plot) fractal method proposed in this paper aims to meet both purposes on the basis of pixel values and pixel value frequency distribution as well as spatial and geometrical properties of image patterns. The C- A method can be used to establish power-law relationships between the area A(⩾ s) with the pixel values greater than s and the pixel value s itself after plotting these values on log-log paper. A number of straight-line segments can be manually or automatically fitted to the points on the log-log paper, each representing a power-law relationship between the area A and the cutoff pixel value for s in a particular range. These straight-line segments can yield a group of cutoff values on the basis of which the image can be classified into discrete classes or zones. These zones usually correspond to the real-world features on the ground. A Windows program has been prepared in ActiveX format for implementing the C- A method and integrating it into other GIS and image processing systems. A case study of Landsat TM band 5 has been used to demonstrate the application of the method and the flexibility of the computer program.
Using the Project Method in Distributive Education. Teacher's Manual.
ERIC Educational Resources Information Center
Maletta, Edwin
The document explains how to integrate the project training methods into a distributive education curriculum for grades 10 or 11. The purpose of this teacher's manual is to give an overall picture of the project method in use. Ten sample projects are included which could apply to any distributive education student concentrating on the major areas…
Conceptual design of a novel multi-DoF manual instrument for laparoscopic surgery.
Wang, Xiaofei; Wang, Shuxin; Li, Jianmin; Zhang, Guokai; Wu, Zhiliang
2013-03-01
Laparoscopic surgery is becoming increasingly popular throughout the world. But the conventional instruments used in many surgeries are not flexible enough to be operated. Challenging tasks, such as suturing and knot-tying tasks are difficult to complete using conventional instruments with limited degrees of freedom (DoFs). In the paper, a novel cable-driven multi-DoF manual instrument is presented with a simple structure but strong functionality. The proposed instrument has been developed with a wristlike operation end (OE), a wristlike end effector (EE), and the transmission system. It can be operated intuitively. The orientation and the position of the EE are directly controlled by surgeons due to the one-to-one motion mapping structure. The clamp structure and tension device are reasonably designed. The pitch, yaw, and the open and close motion are actuated by cables. Based on the optimization index Global Condition Index (GCI), four cables are used to actuate the pitch and yaw motions, while other two are used for the open and close motion. The layout of the cables is also determined by the GCI. Experiments carried out with a prototype show that tasks such as suturing and knot-tying can be completed comfortably. Due to the intuitive control and multi-DoFs, surgeons can use the prototype to finish the tasks with ease. The instrument developed herein with intuitive control and dexterity can be used alone or together with a robotic system to accomplish some challenging tasks that are difficult for conventional instruments. Copyright © 2012 John Wiley & Sons, Ltd.
Evaluation of a completely robotized neurosurgical operating microscope.
Kantelhardt, Sven R; Finke, Markus; Schweikard, Achim; Giese, Alf
2013-01-01
Operating microscopes are essential for most neurosurgical procedures. Modern robot-assisted controls offer new possibilities, combining the advantages of conventional and automated systems. We evaluated the prototype of a completely robotized operating microscope with an integrated optical coherence tomography module. A standard operating microscope was fitted with motors and control instruments, with the manual control mode and balance preserved. In the robot mode, the microscope was steered by a remote control that could be fixed to a surgical instrument. External encoders and accelerometers tracked microscope movements. The microscope was additionally fitted with an optical coherence tomography-scanning module. The robotized microscope was tested on model systems. It could be freely positioned, without forcing the surgeon to take the hands from the instruments or avert the eyes from the oculars. Positioning error was about 1 mm, and vibration faded in 1 second. Tracking of microscope movements, combined with an autofocus function, allowed determination of the focus position within the 3-dimensional space. This constituted a second loop of navigation independent from conventional infrared reflector-based techniques. In the robot mode, automated optical coherence tomography scanning of large surface areas was feasible. The prototype of a robotized optical coherence tomography-integrated operating microscope combines the advantages of a conventional manually controlled operating microscope with a remote-controlled positioning aid and a self-navigating microscope system that performs automated positioning tasks such as surface scans. This demonstrates that, in the future, operating microscopes may be used to acquire intraoperative spatial data, volume changes, and structural data of brain or brain tumor tissue.
Innovative techniques with multi-purpose survey vehicle for automated analysis of cross-slope data.
DOT National Transportation Integrated Search
2007-11-02
Manual surveying methods have long been used in the field of highway engineering to determine : the cross-slope, and longitudinal grade of an existing roadway. However, these methods are : slow, tedious and labor intensive. Moreover, manual survey me...
Calibrating the future highway safety manual predictive methods for Oregon state highways.
DOT National Transportation Integrated Search
2012-02-01
The Highway Safety Manual (HSM) was published by the American Association of State Highway and Transportation Officials (AASHTO) in the spring of 2010. Volume 2 (Part C) of the HSM includes safety predictive methods which can be used to quantitativel...
González-Méijome, José M; López-Alemany, Antonio; Lira, Madalena; Almeida, José B; Oliveira, M Elisabete C D Real; Parafita, Manuel A
2007-01-01
The purpose of the present study was to develop mathematical relationships that allow obtaining equilibrium water content and refractive index of conventional and silicone hydrogel soft contact lenses from refractive index measures obtained with automated refractometry or equilibrium water content measures derived from manual refractometry, respectively. Twelve HEMA-based hydrogels of different hydration and four siloxane-based polymers were assayed. A manual refractometer and a digital refractometer were used. Polynomial models obtained from the sucrose curves of equilibrium water content against refractive index and vice-versa were used either considering the whole range of sucrose concentrations (16-100% equilibrium water content) or a range confined to the equilibrium water content of current soft contact lenses (approximately 20-80% equilibrium water content). Values of equilibrium water content measured with the Atago N-2E and those derived from the refractive index measurement with CLR 12-70 by the applications of sucrose-based models displayed a strong linear correlation (r2 = 0.978). The same correlations were obtained when the models are applied to obtain refractive index values from the Atago N-2E and compared with those (values) given by the CLR 12-70 (r2 = 0.978). No significantly different results are obtained between models derived from the whole range of the sucrose solution or the model limited to the normal range of soft contact lens hydration. Present results will have implications for future experimental and clinical research regarding normal hydration and dehydration experiments with hydrogel polymers, and particularly in the field of contact lenses. 2006 Wiley Periodicals, Inc.
Computer-aided target tracking in motion analysis studies
NASA Astrophysics Data System (ADS)
Burdick, Dominic C.; Marcuse, M. L.; Mislan, J. D.
1990-08-01
Motion analysis studies require the precise tracking of reference objects in sequential scenes. In a typical situation, events of interest are captured at high frame rates using special cameras, and selected objects or targets are tracked on a frame by frame basis to provide necessary data for motion reconstruction. Tracking is usually done using manual methods which are slow and prone to error. A computer based image analysis system has been developed that performs tracking automatically. The objective of this work was to eliminate the bottleneck due to manual methods in high volume tracking applications such as the analysis of crash test films for the automotive industry. The system has proven to be successful in tracking standard fiducial targets and other objects in crash test scenes. Over 95 percent of target positions which could be located using manual methods can be tracked by the system, with a significant improvement in throughput over manual methods. Future work will focus on the tracking of clusters of targets and on tracking deformable objects such as airbags.
Manual of analytical methods for the Environmental Health Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gray, C. E.
1975-06-01
This manual was compiled from techniques used In the Environmental Health Laboratory of Sandia Laboratories at Albuquerque. New Mexico, and is a revision of an earlier publication (SC-M-07-3044) edited by Lial W. Brewer. The procedures arc similar to those used in other laboratories devoted to Environmental Health practices. Some of the methods are standard and others are modified to suit our needs; others were developed at Sandia. The author has attempted to present all methods in a simple and concise manner, but in sufficient detail to make them readily usable. It is not inferred that the methods are universal formore » any type of sample, but they have been found very reliable for the types of samples mentioned. The author will welcome inquiry for clarification of any part of this manual. It is the desire of the author that this manual will be of use and service to others. New and revised procedures will be issued as supplements to this document.« less
Quartermaster 1 and C, Rate Training Manual.
ERIC Educational Resources Information Center
Naval Personnel Program Support Activity, Washington, DC.
The technical subject matter of the Quartermaster rating is presented in this training manual written to prepare men of the Navy and Naval Reserve for advancement examinations. The manual includes eleven chapters. Discussed are commonly used methods and procedures of operating magnetic compasses and gyrocompasses, determining a ship's position,…
Manual for the Comparative Politics Laboratory: Conditions for Effective Democracy.
ERIC Educational Resources Information Center
Fogelman, Edwin; Zingale, Nancy
This manual introduces undergraduate students in political science to major types of data and methods for cross-national quantitative analysis. The manual's topic, Conditions for Effective Democracy, was chosen because it incorporates several different kinds of data and illustrates various methodological problems. The data are cross-sectional…
English in the Work Place for School Custodians. Manual and Curriculum Guide.
ERIC Educational Resources Information Center
Cruz, Jane; And Others
This manual is intended to assist in the development of programs in vocational English as a Second Language (VESL) for limited-English-speaking individuals working as school custodians. The manual describes steps in program development, offers methods for needs assessment, specifies instructional objectives, discusses techniques for lesson…
Washington Manual: A New Tool for Local School Accounting
ERIC Educational Resources Information Center
Federal Aid Planner, 1972
1972-01-01
An advance glimpse of the revised financial accounting methods for school districts recommended in a new manual from the U. S. Office of Education. The manual is designed to help school districts modernize their financial accounting procedures and their entire range of fiscal management practices. (Author/DN)
40 CFR 58.12 - Operating schedules.
Code of Federal Regulations, 2014 CFR
2014-07-01
... seasons exempted by the Regional Administrator. (b) For Pb manual methods, at least one 24-hour sample must be collected every 6 days except during periods or seasons exempted by the Regional Administrator... and must be approved by the Regional Administrator. (d) For manual PM 2.5 samplers: (1)(i) Manual PM 2...
40 CFR 58.12 - Operating schedules.
Code of Federal Regulations, 2013 CFR
2013-07-01
... seasons exempted by the Regional Administrator. (b) For Pb manual methods, at least one 24-hour sample must be collected every 6 days except during periods or seasons exempted by the Regional Administrator... and must be approved by the Regional Administrator. (d) For manual PM 2.5 samplers: (1)(i) Manual PM 2...
Vohra, Rais; Kelner, Michael; Clark, Richard F
2009-01-01
Crotaline Polyvalent Ovine Fab antivenom (CroFab, Savage Laboratories and Protherics Inc., Brentwood, TN, USA) preparation requires that the lyophilized powder be manually reconstituted before use. We compared automated methods for driving the product into solution with the standard manual method of reconstitution, and the effect of repeated rinsing of the product vial, on the per-vial availability of antivenom. Normal saline (NS, 10 mL) was added to 12 vials of expired CroFab. Vials were assigned in pairs to each of six mixing methods, including one pair mixed manually as recommended by the product package insert. Each vial's contents were diluted to a final volume of 75 mL of normal saline. Protein concentration was measured with a colorimetric assay. The fluid left in each vial was removed and the vial was washed with 10 mL NS. Total protein yield from each step was calculated. There was no significant change in protein yield among three of five automated mixing methods when compared to manual reconstitution. Repeat rinsing of the product vial with an additional 10 mLs of fluid added to the protein yield regardless of the mixing method used. We found slightly higher protein yields with all automated methods compared to manual mixing, but only two of five comparisons with the standard mixing method demonstrated statistical significance. However, for all methods tested, the addition of a second rinsing and recovery step increased the amount of protein recovered considerably, presumably by allowing solution of protein trapped in the foamy residues. Automated mixing methods and repeat rinsing of the product vial may allow higher protein yields in the preparation of CroFab antivenom.
Kulkarni, Raghavendra D.; Mishra, Mukti Nath; Mohanraj, Jeevanandam; Chandrasekhar, Arun; Ajantha, G. S.; Kulkani, Sheetal; Bhat, Shama
2018-01-01
BACKGROUND: Nosocomial infections are often caused by multidrug-resistant bacteria and the incidence is increasing. Acinetobacter, a Gram-negative bacillus, is commonly associated with the use of intravascular catheterization and airway intubation. Polymerase chain reaction (PCR) for identification of Acinetobacter baumannii from samples has been standardized that use conventional wet-reagent mix. We have designed and optimized a dry-reagent mix for identification of Acinetobacter species by PCR. The dry-reagent mix can be stored at room temperature, has less chances of contamination, and thus can be used at point-of-care diagnosis. AIM AND OBJECTIVE: The present work was focused on comparing the sensitivity and specificity of dry-reagent PCR mix over conventional wet-reagent PCR mix for identification of Acinetobacter species. MATERIALS AND METHODS: Conventional wet-reagent mix based and dry-reagent mix based PCR were carried out for the DNA isolated from Acinetobacter species. The latter was also applied directly on bacterial growth without prior DNA extraction process. Equal numbers of bacterial isolates other than Acinetobacter species were also subjected to identification by the same protocols for determining the sensitivity and specificity of the test. RESULTS: The Acinetobacter species showed amplification of the target rpoB gene and the band was observed at 397 bp. The dry-reagent PCR mix results matched completely with the conventional wet-reagent PCR mix assay. All the non-Acinetobacter isolates were negative for the PCR. This indicates that the test is highly specific. The dry-reagent mix also contained an enzyme resistant to PCR inhibitors and capable of amplifying DNA directly from cells. CONCLUSION: Performance of dry-reagent PCR mix without the need for DNA extraction and preparation of a PCR mix proved to be more sensitive and reduce the handling error, minimizes the time, manual work, and skilled labor. PMID:29403209
Method of converting an existing vehicle powertrain to a hybrid powertrain system
Reed, Jr., Richard G.; Boberg, Evan S.; Lawrie, Robert E.; Castaing, Francois J.
2001-12-25
A method of converting an existing vehicle powertrain including a manual transmission to a hybrid powertrain system with an automated powertrain transmission. The first step in the method of attaching a gear train housing to a housing of said manual transmission, said gear train housing receiving as end of drive shaft of said transmission and rotatably supporting a gear train assembly. Secondly, mounting an electric motor/generator to said gear train housing and attaching a motor/generator drive shaft of said electric motor/generator to said gear train assembly. Lastly, connecting an electro-mechanical clutch actuator to a friction clutch mechanism of said manual transmission.
Evaluation of mouse red blood cell and platelet counting with an automated hematology analyzer.
Fukuda, Teruko; Asou, Eri; Nogi, Kimiko; Goto, Kazuo
2017-10-07
An evaluation of mouse red blood cell (RBC) and platelet (PLT) counting with an automated hematology analyzer was performed with three strains of mice, C57BL/6 (B6), BALB/c (BALB) and DBA/2 (D2). There were no significant differences in RBC and PLT counts between manual and automated optical methods in any of the samples, except for D2 mice. For D2, RBC counts obtained using the manual method were significantly lower than those obtained using the automated optical method (P<0.05), and PLT counts obtained using the manual method were higher than those obtained using the automated optical method (P<0.05). An automated hematology analyzer can be used for RBC and PLT counting; however, an appropriate method should be selected when D2 mice samples are used.
Battery Calendar Life Estimator Manual Modeling and Simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jon P. Christophersen; Ira Bloom; Ed Thomas
2012-10-01
The Battery Life Estimator (BLE) Manual has been prepared to assist developers in their efforts to estimate the calendar life of advanced batteries for automotive applications. Testing requirements and procedures are defined by the various manuals previously published under the United States Advanced Battery Consortium (USABC). The purpose of this manual is to describe and standardize a method for estimating calendar life based on statistical models and degradation data acquired from typical USABC battery testing.
Battery Life Estimator Manual Linear Modeling and Simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jon P. Christophersen; Ira Bloom; Ed Thomas
2009-08-01
The Battery Life Estimator (BLE) Manual has been prepared to assist developers in their efforts to estimate the calendar life of advanced batteries for automotive applications. Testing requirements and procedures are defined by the various manuals previously published under the United States Advanced Battery Consortium (USABC). The purpose of this manual is to describe and standardize a method for estimating calendar life based on statistical models and degradation data acquired from typical USABC battery testing.
ERIC Educational Resources Information Center
Kouimtsidis, Christos; Scior, Katrina; Baio, Gianluca; Hunter, Rachael; Pezzoni, Vittoria; Hassiotis, Angela
2017-01-01
Background: Extended brief interventions for alcohol misuse are effective in the general population. The process of manualising the first ever such intervention for people with mild to moderate intellectual disabilities in the UK is the focus of this study. Methods: The manual was an adaptation of existing manuals based on Motivational Enhancement…
Shachak, Aviv; Dow, Rustam; Barnsley, Jan; Tu, Karen; Domb, Sharon; Jadad, Alejandro R; Lemieux-Charles, Louise
2013-06-04
Tutorials and user manuals are important forms of impersonal support for using software applications including electronic medical records (EMRs). Differences between user- and vendor documentation may indicate support needs, which are not sufficiently addressed by the official documentation, and reveal new elements that may inform the design of tutorials and user manuals. What are the differences between user-generated tutorials and manuals for an EMR and the official user manual from the software vendor? Effective design of tutorials and user manuals requires careful packaging of information, balance between declarative and procedural texts, an action and task-oriented approach, support for error recognition and recovery, and effective use of visual elements. No previous research compared these elements between formal and informal documents. We conducted an mixed methods study. Seven tutorials and two manuals for an EMR were collected from three family health teams and compared with the official user manual from the software vendor. Documents were qualitatively analyzed using a framework analysis approach in relation to the principles of technical documentation described above. Subsets of the data were quantitatively analyzed using cross-tabulation to compare the types of error information and visual cues in screen captures between user- and vendor-generated manuals. The user-developed tutorials and manuals differed from the vendor-developed manual in that they contained mostly procedural and not declarative information; were customized to the specific workflow, user roles, and patient characteristics; contained more error information related to work processes than to software usage; and used explicit visual cues on screen captures to help users identify window elements. These findings imply that to support EMR implementation, tutorials and manuals need to be customized and adapted to specific organizational contexts and workflows. The main limitation of the study is its generalizability. Future research should address this limitation and may explore alternative approaches to software documentation, such as modular manuals or participatory design.
Hovnanians, Ninel; Win, Theresa; Makkiya, Mohammed; Zheng, Qi; Taub, Cynthia
2017-11-01
To assess the efficiency and reproducibility of automated measurements of left ventricular (LV) volumes and LV ejection fraction (LVEF) in comparison to manually traced biplane Simpson's method. This is a single-center prospective study. Apical four- and two-chamber views were acquired in patients in sinus rhythm. Two operators independently measured LV volumes and LVEF using biplane Simpson's method. In addition, the image analysis software a2DQ on the Philips EPIQ system was applied to automatically assess the LV volumes and LVEF. Time spent on each analysis, using both methods, was documented. Concordance of echocardiographic measures was evaluated using intraclass correlation (ICC) and Bland-Altman analysis. Manual tracing and automated measurement of LV volumes and LVEF were performed in 184 patients with a mean age of 67.3 ± 17.3 years and BMI 28.0 ± 6.8 kg/m 2 . ICC and Bland-Altman analysis showed good agreements between manual and automated methods measuring LVEF, end-systolic, and end-diastolic volumes. The average analysis time was significantly less using the automated method than manual tracing (116 vs 217 seconds/patient, P < .0001). Automated measurement using the novel image analysis software a2DQ on the Philips EPIQ system produced accurate, efficient, and reproducible assessment of LV volumes and LVEF compared with manual measurement. © 2017, Wiley Periodicals, Inc.
van der Slegt, Jasper; Verbogt, Nathalie Pa; Mulder, Paul Gh; Steunenberg, Stijn L; Steunenberg, Bastiaan E; van der Laan, Lijckle
2016-10-01
An automated ankle-brachial index device could lead to potential time savings and more accuracy in ankle-brachial index-determination after vascular surgery. This prospective cross-sectional study compared postprocedural ankle-brachial indices measured by a manual method with ankle-brachial indices of an automated plethysmographic method. Forty-two patients were included. No significant difference in time performing a measurement was observed (1.1 min, 95% CI: -0.2 to +2.4; P = 0.095). Mean ankle-brachial index with the automated method was 0.105 higher (95% CI: 0.017 to 0.193; P = 0.020) than with the manual method, with limits of agreement of -0.376 and +0.587. Total variance amounted to 0.0759 and the correlation between both methods was 0.60. Reliability expressed as maximum absolute difference (95% level) between duplicate ankle-brachial index-measurements under identical conditions was 0.350 (manual) and 0.152 (automated), although not significant (p = 0.053). Finally, the automated method had 34% points higher failure rate than the manual method. In conclusion based on this study, the automated ankle-brachial index-method seems not to be clinically applicable for measuring ankle-brachial index postoperatively in patients with vascular disease. © The Author(s) 2016.
Physiological closed-loop control in intelligent oxygen therapy: A review.
Sanchez-Morillo, Daniel; Olaby, Osama; Fernandez-Granero, Miguel Angel; Leon-Jimenez, Antonio
2017-07-01
Oxygen therapy has become a standard care for the treatment of patients with chronic obstructive pulmonary disease and other hypoxemic chronic lung diseases. In current systems, manually continuous adjustment of O 2 flow rate is a time-consuming task, often unsuccessful, that requires experienced staff. The primary aim of this systematic review is to collate and report on the principles, algorithms and accuracy of autonomous physiological close-loop controlled oxygen devices as well to present recommendations for future research and studies in this area. A literature search was performed on medical database MEDLINE, engineering database IEEE-Xplore and wide-raging scientific databases Scopus and Web of Science. A narrative synthesis of the results was carried out. A summary of the findings of this review suggests that when compared to the conventional manual practice, the closed-loop controllers maintain higher saturation levels, spend less time below the target saturation, and save oxygen resources. Nonetheless, despite of their potential, autonomous oxygen therapy devices are scarce in real clinical applications. Robustness of control algorithms, fail-safe mechanisms, limited reliability of sensors, usability issues and the need for standardized evaluating methods of assessing risks can be among the reasons for this lack of matureness and need to be addressed before the wide spreading of a new generation of automatic oxygen devices. Copyright © 2017 Elsevier B.V. All rights reserved.
Zheng, Tingting; Gao, Zhigang; Luo, Yong; Liu, Xianming; Zhao, Weijie; Lin, Bingcheng
2016-02-01
Clenbuterol (CL), as a feed additive, has been banned in many countries due to its potential threat to human health. In detection of CL, a fast, low-cost technique with high accuracy and specificity would be ideal for its administrative on-field inspections. Among the attempts to pursue a reliable detection tool of CL, a technique that combines surface enhanced Raman spectroscopy (SERS) and immunoassay, is close to meet the requirements as above. However, multiple steps of interactions between CL analyte, antibody, and antigen are involved in this method, and under conventional setup, the operation of SERS/immunoassay were unwieldy. In this paper, to facilitate a more manageable sample manipulation for SERS-immunoassay measurement, a 3D paper chip was suggested. A switch-on-chip multilayered (abbreviated as SoCM-) microfluidic paper-based analysis device (μPad) was fabricated to provide operators with manual switches on the interactions between different microfluids. Besides, on a detection slip we made on the main body of our SoCM-μPad, antigen was anchored in pattern. With this architecture, multistep interactions between the CL analyte in swine hair extract and the SERS probe-modified antibody and antigen, were managed for on-chip SERS-immunoassay detection. This would be very attractive for fast, cheap, accurate, and on-site specific detection of CL from real samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Simply Great Cooking Instruction. A Manual for Teaching Cooking to Non-Reading Students.
ERIC Educational Resources Information Center
Sesto, Cameron
This manual presents a method of teaching cooking to nonreaders. The language of the method consists of visual symbols, such as drawings of bowls, spoons, and ingredients, and color. The "Simply Great" method consists of three basic formats: the one-step booklet, the full-page format, and the simply written for the student with some…
Bone marrow cavity segmentation using graph-cuts with wavelet-based texture feature.
Shigeta, Hironori; Mashita, Tomohiro; Kikuta, Junichi; Seno, Shigeto; Takemura, Haruo; Ishii, Masaru; Matsuda, Hideo
2017-10-01
Emerging bioimaging technologies enable us to capture various dynamic cellular activities [Formula: see text]. As large amounts of data are obtained these days and it is becoming unrealistic to manually process massive number of images, automatic analysis methods are required. One of the issues for automatic image segmentation is that image-taking conditions are variable. Thus, commonly, many manual inputs are required according to each image. In this paper, we propose a bone marrow cavity (BMC) segmentation method for bone images as BMC is considered to be related to the mechanism of bone remodeling, osteoporosis, and so on. To reduce manual inputs to segment BMC, we classified the texture pattern using wavelet transformation and support vector machine. We also integrated the result of texture pattern classification into the graph-cuts-based image segmentation method because texture analysis does not consider spatial continuity. Our method is applicable to a particular frame in an image sequence in which the condition of fluorescent material is variable. In the experiment, we evaluated our method with nine types of mother wavelets and several sets of scale parameters. The proposed method with graph-cuts and texture pattern classification performs well without manual inputs by a user.
Gnjidic, Danijela; Pearson, Sallie-Anne; Hilmer, Sarah N; Basilakis, Jim; Schaffer, Andrea L; Blyth, Fiona M; Banks, Emily
2015-03-30
Increasingly, automated methods are being used to code free-text medication data, but evidence on the validity of these methods is limited. To examine the accuracy of automated coding of previously keyed in free-text medication data compared with manual coding of original handwritten free-text responses (the 'gold standard'). A random sample of 500 participants (475 with and 25 without medication data in the free-text box) enrolled in the 45 and Up Study was selected. Manual coding involved medication experts keying in free-text responses and coding using Anatomical Therapeutic Chemical (ATC) codes (i.e. chemical substance 7-digit level; chemical subgroup 5-digit; pharmacological subgroup 4-digit; therapeutic subgroup 3-digit). Using keyed-in free-text responses entered by non-experts, the automated approach coded entries using the Australian Medicines Terminology database and assigned corresponding ATC codes. Based on manual coding, 1377 free-text entries were recorded and, of these, 1282 medications were coded to ATCs manually. The sensitivity of automated coding compared with manual coding was 79% (n = 1014) for entries coded at the exact ATC level, and 81.6% (n = 1046), 83.0% (n = 1064) and 83.8% (n = 1074) at the 5, 4 and 3-digit ATC levels, respectively. The sensitivity of automated coding for blank responses was 100% compared with manual coding. Sensitivity of automated coding was highest for prescription medications and lowest for vitamins and supplements, compared with the manual approach. Positive predictive values for automated coding were above 95% for 34 of the 38 individual prescription medications examined. Automated coding for free-text prescription medication data shows very high to excellent sensitivity and positive predictive values, indicating that automated methods can potentially be useful for large-scale, medication-related research.
Improving Air Force Imagery Reconnaissance Support to Ground Commanders.
1983-06-03
reconnaissance support in Southeast Asia due to the long response times of film recovery and 26 processing capabilities and inadequate command and control...reconnaissance is an integral part of the C31 information explosion. Traditional silver halide film products, chemically processed and manually distributed are...being replaced with electronic near-real-time (NRT) imaging sensors. The term "imagery" now includes not only conventional film based products (black
Different Strokes for Different Folks: Visual Presentation Design between Disciplines
Gomez, Steven R.; Jianu, Radu; Ziemkiewicz, Caroline; Guo, Hua; Laidlaw, David H.
2015-01-01
We present an ethnographic study of design differences in visual presentations between academic disciplines. Characterizing design conventions between users and data domains is an important step in developing hypotheses, tools, and design guidelines for information visualization. In this paper, disciplines are compared at a coarse scale between four groups of fields: social, natural, and formal sciences; and the humanities. Two commonplace presentation types were analyzed: electronic slideshows and whiteboard “chalk talks”. We found design differences in slideshows using two methods – coding and comparing manually-selected features, like charts and diagrams, and an image-based analysis using PCA called eigenslides. In whiteboard talks with controlled topics, we observed design behaviors, including using representations and formalisms from a participant’s own discipline, that suggest authors might benefit from novel assistive tools for designing presentations. Based on these findings, we discuss opportunities for visualization ethnography and human-centered authoring tools for visual information. PMID:26357149
Nawyn, John P.; Sargent, B. Pierre; Hoopes, Barbara; Augenstein, Todd; Rowland, Kathleen M.; Barber, Nancy L.
2017-10-06
The Aggregate Water-Use Data System (AWUDS) is the database management system used to enter, store, and analyze state aggregate water-use data. It is part of the U.S. Geological Survey National Water Information System. AWUDS has a graphical user interface that facilitates data entry, revision, review, and approval. This document provides information on the basic functions of AWUDS and the steps for carrying out common tasks that are a part of compiling an aggregated dataset. Also included are explanations of terminology and descriptions of user-interface structure, procedures for using the AWUDS operations, and dataset-naming conventions. Information on water-use category definitions, data-collection methods, and data sources are found in the report “Guidelines for preparation of State water-use estimates,” available at https://pubs.er.usgs.gov/publication/ofr20171029.
Targeted post-mortem computed tomography cardiac angiography: proof of concept.
Saunders, Sarah L; Morgan, Bruno; Raj, Vimal; Robinson, Claire E; Rutty, Guy N
2011-07-01
With the increasing use and availability of multi-detector computed tomography and magnetic resonance imaging in autopsy practice, there has been an international push towards the development of the so-called near virtual autopsy. However, currently, a significant obstacle to the consideration as to whether or not near virtual autopsies could one day replace the conventional invasive autopsy is the failure of post-mortem imaging to yield detailed information concerning the coronary arteries. To date, a cost-effective, practical solution to allow high throughput imaging has not been presented within the forensic literature. We present a proof of concept paper describing a simple, quick, cost-effective, manual, targeted in situ post-mortem cardiac angiography method using a minimally invasive approach, to be used with multi-detector computed tomography for high throughput cadaveric imaging which can be used in permanent or temporary mortuaries.
Measurement of surface microtopography
NASA Technical Reports Server (NTRS)
Wall, S. D.; Farr, T. G.; Muller, J.-P.; Lewis, P.; Leberl, F. W.
1991-01-01
Acquisition of ground truth data for use in microwave interaction modeling requires measurement of surface roughness sampled at intervals comparable to a fraction of the microwave wavelength and extensive enough to adequately represent the statistics of a surface unit. Sub-centimetric measurement accuracy is thus required over large areas, and existing techniques are usually inadequate. A technique is discussed for acquiring the necessary photogrammetric data using twin film cameras mounted on a helicopter. In an attempt to eliminate tedious data reduction, an automated technique was applied to the helicopter photographs, and results were compared to those produced by conventional stereogrammetry. Derived root-mean-square (RMS) roughness for the same stereo-pair was 7.5 cm for the automated technique versus 6.5 cm for the manual method. The principal source of error is probably due to vegetation in the scene, which affects the automated technique but is ignored by a human operator.
Different Strokes for Different Folks: Visual Presentation Design between Disciplines.
Gomez, S R; Jianu, R; Ziemkiewicz, C; Guo, Hua; Laidlaw, D H
2012-12-01
We present an ethnographic study of design differences in visual presentations between academic disciplines. Characterizing design conventions between users and data domains is an important step in developing hypotheses, tools, and design guidelines for information visualization. In this paper, disciplines are compared at a coarse scale between four groups of fields: social, natural, and formal sciences; and the humanities. Two commonplace presentation types were analyzed: electronic slideshows and whiteboard "chalk talks". We found design differences in slideshows using two methods - coding and comparing manually-selected features, like charts and diagrams, and an image-based analysis using PCA called eigenslides. In whiteboard talks with controlled topics, we observed design behaviors, including using representations and formalisms from a participant's own discipline, that suggest authors might benefit from novel assistive tools for designing presentations. Based on these findings, we discuss opportunities for visualization ethnography and human-centered authoring tools for visual information.
Application of Digital Anthropometry for Craniofacial Assessment
Jayaratne, Yasas S. N.; Zwahlen, Roger A.
2014-01-01
Craniofacial anthropometry is an objective technique based on a series of measurements and proportions, which facilitate the characterization of phenotypic variation and quantification of dysmorphology. With the introduction of stereophotography, it is possible to acquire a lifelike three-dimensional (3D) image of the face with natural color and texture. Most of the traditional anthropometric landmarks can be identified on these 3D photographs using specialized software. Therefore, it has become possible to compute new digital measurements, which were not feasible with traditional instruments. The term “digital anthropometry” has been used by researchers based on such systems to separate their methods from conventional manual measurements. Anthropometry has been traditionally used as a research tool. With the advent of digital anthropometry, this technique can be employed in several disciplines as a noninvasive tool for quantifying facial morphology. The aim of this review is to provide a broad overview of digital anthropometry and discuss its clinical applications. PMID:25050146
Task-oriented lossy compression of magnetic resonance images
NASA Astrophysics Data System (ADS)
Anderson, Mark C.; Atkins, M. Stella; Vaisey, Jacques
1996-04-01
A new task-oriented image quality metric is used to quantify the effects of distortion introduced into magnetic resonance images by lossy compression. This metric measures the similarity between a radiologist's manual segmentation of pathological features in the original images and the automated segmentations performed on the original and compressed images. The images are compressed using a general wavelet-based lossy image compression technique, embedded zerotree coding, and segmented using a three-dimensional stochastic model-based tissue segmentation algorithm. The performance of the compression system is then enhanced by compressing different regions of the image volume at different bit rates, guided by prior knowledge about the location of important anatomical regions in the image. Application of the new system to magnetic resonance images is shown to produce compression results superior to the conventional methods, both subjectively and with respect to the segmentation similarity metric.
Maret, Eva; Brudin, Lars; Lindstrom, Lena; Nylander, Eva; Ohlsson, Jan L; Engvall, Jan E
2008-01-01
Background Left ventricular size and function are important prognostic factors in heart disease. Their measurement is the most frequent reason for sending patients to the echo lab. These measurements have important implications for therapy but are sensitive to the skill of the operator. Earlier automated echo-based methods have not become widely used. The aim of our study was to evaluate an automatic echocardiographic method (with manual correction if needed) for determining left ventricular ejection fraction (LVEF) based on an active appearance model of the left ventricle (syngo®AutoEF, Siemens Medical Solutions). Comparisons were made with manual planimetry (manual Simpson), visual assessment and automatically determined LVEF from quantitative myocardial gated single photon emission computed tomography (SPECT). Methods 60 consecutive patients referred for myocardial perfusion imaging (MPI) were included in the study. Two-dimensional echocardiography was performed within one hour of MPI at rest. Image quality did not constitute an exclusion criterion. Analysis was performed by five experienced observers and by two novices. Results LVEF (%), end-diastolic and end-systolic volume/BSA (ml/m2) were for uncorrected AutoEF 54 ± 10, 51 ± 16, 24 ± 13, for corrected AutoEF 53 ± 10, 53 ± 18, 26 ± 14, for manual Simpson 51 ± 11, 56 ± 20, 28 ± 15, and for MPI 52 ± 12, 67 ± 26, 35 ± 23. The required time for analysis was significantly different for all four echocardiographic methods and was for uncorrected AutoEF 79 ± 5 s, for corrected AutoEF 159 ± 46 s, for manual Simpson 177 ± 66 s, and for visual assessment 33 ± 14 s. Compared with the expert manual Simpson, limits of agreement for novice corrected AutoEF was lower than for novice manual Simpson (0.8 ± 10.5 vs. -3.2 ± 11.4 LVEF percentage points). Calculated for experts and with LVEF (%) categorized into < 30, 30–44, 45–54 and ≥ 55, kappa measure of agreement was moderate (0.44–0.53) for all method comparisons (uncorrected AutoEF not evaluated). Conclusion Corrected AutoEF reduces the variation in measurements compared with manual planimetry, without increasing the time required. The method seems especially suited for unexperienced readers. PMID:19014461
Expressive Vocabulary Acquisition in Children with Intellectual Disability: Speech or Manual Signs?
ERIC Educational Resources Information Center
Vandereet, Joke; Maes, Bea; Lembrechts, Dirk; Zink, Inge
2011-01-01
Background: The aim of this study was to examine the degree to which children with intellectual disability (ID) depend on manual signs during their expressive vocabulary acquisition, in relation to child and social-environmental characteristics. Method: Expressive vocabulary acquisition in speech and manual signs was monitored over a 2-year period…
Animal Traction. Appropriate Technologies for Development. Manual M-12.
ERIC Educational Resources Information Center
Watson, Peter R.
This manual is designed for use by Peace Corps volunteers and agricultural extension personnel working in animal traction development programs. While some of the information contained in the manual is specific to the extension of animal-powered agriculture in Africa, the principles covered are generally applicable wherever the method is being used…
Manual for Identification of Limited-English Proficiency Students with Special Needs. Report #11785.
ERIC Educational Resources Information Center
Ambert, Alba N.; And Others
This manual, intended to assist teachers in identifying students with limited-English proficiency who may have special needs, concentrates on four areas: language, observation, testing, and learning problems. The main part of the manual has eight sections dealing with the following topics: (1) observation techniques and methods; (2) modifications…
Infant and Toddler Oral- and Manual-Motor Skills Predict Later Speech Fluency in Autism
ERIC Educational Resources Information Center
Gernsbacher, Morton Ann; Sauer, Eve A.; Geye, Heather M.; Schweigert, Emily K.; Goldsmith, H. Hill
2008-01-01
Background: Spoken and gestural communication proficiency varies greatly among autistic individuals. Three studies examined the role of oral- and manual-motor skill in predicting autistic children's speech development. Methods: Study 1 investigated whether infant and toddler oral- and manual-motor skills predict middle childhood and teenage speech…
40 CFR 58.12 - Operating schedules.
Code of Federal Regulations, 2012 CFR
2012-07-01
... seasons exempted by the Regional Administrator. (b) For Pb manual methods, at least one 24-hour sample must be collected every 6 days except during periods or seasons exempted by the Regional Administrator... and must be approved by the Regional Administrator. (d) For manual PM2.5 samplers: (1)(i) Manual PM2.5...
Assessing the economics of processing end-of-life vehicles through manual dismantling.
Tian, Jin; Chen, Ming
2016-10-01
Most dismantling enterprises in a number of developing countries, such as China, usually adopt the "manual+mechanical" dismantling approach to process end-of-life vehicles. However, the automobile industry does not have a clear indicator to reasonably and effectively determine the manual dismantling degree for end-of-life vehicles. In this study, five different dismantling scenarios and an economic system for end-of-life vehicles were developed based on the actual situation of end-of-life vehicles. The fuzzy analytic hierarchy process was applied to set the weights of direct costs, indirect costs, and sales and to obtain an optimal manual dismantling scenario. Results showed that although the traditional method of "dismantling to the end" can guarantee the highest recycling rate, this method is not the best among all the scenarios. The profit gained in the optimal scenario is 100.6% higher than that in the traditional scenario. The optimal manual dismantling scenario showed that enterprises are required to select suitable parts to process through manual dismantling. Selecting suitable parts maximizes economic profit and improves dismantling speed. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Cinar, A. F.; Barhli, S. M.; Hollis, D.; Flansbjer, M.; Tomlinson, R. A.; Marrow, T. J.; Mostafavi, M.
2017-09-01
Digital image correlation has been routinely used to measure full-field displacements in many areas of solid mechanics, including fracture mechanics. Accurate segmentation of the crack path is needed to study its interaction with the microstructure and stress fields, and studies of crack behaviour, such as the effect of closure or residual stress in fatigue, require data on its opening displacement. Such information can be obtained from any digital image correlation analysis of cracked components, but it collection by manual methods is quite onerous, particularly for massive amounts of data. We introduce the novel application of Phase Congruency to detect and quantify cracks and their opening. Unlike other crack detection techniques, Phase Congruency does not rely on adjustable threshold values that require user interaction, and so allows large datasets to be treated autonomously. The accuracy of the Phase Congruency based algorithm in detecting cracks is evaluated and compared with conventional methods such as Heaviside function fitting. As Phase Congruency is a displacement-based method, it does not suffer from the noise intensification to which gradient-based methods (e.g. strain thresholding) are susceptible. Its application is demonstrated to experimental data for cracks in quasi-brittle (Granitic rock) and ductile (Aluminium alloy) materials.
Virtual and stereoscopic anatomy: when virtual reality meets medical education.
de Faria, Jose Weber Vieira; Teixeira, Manoel Jacobsen; de Moura Sousa Júnior, Leonardo; Otoch, Jose Pinhata; Figueiredo, Eberval Gadelha
2016-11-01
OBJECTIVE The authors sought to construct, implement, and evaluate an interactive and stereoscopic resource for teaching neuroanatomy, accessible from personal computers. METHODS Forty fresh brains (80 hemispheres) were dissected. Images of areas of interest were captured using a manual turntable and processed and stored in a 5337-image database. Pedagogic evaluation was performed in 84 graduate medical students, divided into 3 groups: 1 (conventional method), 2 (interactive nonstereoscopic), and 3 (interactive and stereoscopic). The method was evaluated through a written theory test and a lab practicum. RESULTS Groups 2 and 3 showed the highest mean scores in pedagogic evaluations and differed significantly from Group 1 (p < 0.05). Group 2 did not differ statistically from Group 3 (p > 0.05). Size effects, measured as differences in scores before and after lectures, indicate the effectiveness of the method. ANOVA results showed significant difference (p < 0.05) between groups, and the Tukey test showed statistical differences between Group 1 and the other 2 groups (p < 0.05). No statistical differences between Groups 2 and 3 were found in the practicum. However, there were significant differences when Groups 2 and 3 were compared with Group 1 (p < 0.05). CONCLUSIONS The authors conclude that this method promoted further improvement in knowledge for students and fostered significantly higher learning when compared with traditional teaching resources.
Weckesser, M; Griessmeier, M; Schmidt, D; Sonnenberg, F; Ziemons, K; Kemna, L; Holschbach, M; Langen, K; Müller-Gärtner, H
1998-02-01
Single-photon emission tomography (SPET) with the amino acid analogue l-3-[123I]iodo-alpha-methyl tyrosine (IMT) is helpful in the diagnosis and monitoring of cerebral gliomas. Radiolabelled amino acids seem to reflect tumour infiltration more specifically than conventional methods like magnetic resonance imaging and computed tomography. Automatic tumour delineation based on maximal tumour uptake may cause an overestimation of mean tumour uptake and an underestimation of tumour extension in tumours with circumscribed peaks. The aim of this study was to develop a program for tumour delineation and calculation of mean tumour uptake which takes into account the mean background activity and is thus optimised to the problem of tumour definition in IMT SPET. Using the frequency distribution of pixel intensities of the tomograms a program was developed which automatically detects a reference brain region and draws an isocontour region around the tumour taking into account mean brain radioactivity. Tumour area and tumour/brain ratios were calculated. A three-compartment phantom was simulated to test the program. The program was applied to IMT SPET studies of 20 patients with cerebral gliomas and was compared to the results of manual analysis by three different investigators. Activity ratios and chamber extension of the phantom were correctly calculated by the automatic analysis. A method based on image maxima alone failed to determine chamber extension correctly. Manual region of interest analysis in patient studies resulted in a mean inter-observer standard deviation of 8.7% +/ -6.1% (range 2.7% -25.0%). The mean value of the results of the manual analysis showed a significant correlation to the results of the automatic analysis (r = 0.91, P<0. 0001 for the uptake ratio; r = 0.87, P<0.0001 for the tumour area). We conclude that the algorithm proposed simplifies the calculation of uptake ratios and may be used for observer-independent evaluation of IMT SPET studies. Three-dimensional tumour recognition and transfer to co-registered morphological images based on this program may be useful for the planning of surgical and radiation treatment.
Intelligent navigation to improve obstetrical sonography.
Yeo, Lami; Romero, Roberto
2016-04-01
'Manual navigation' by the operator is the standard method used to obtain information from two-dimensional and volumetric sonography. Two-dimensional sonography is highly operator dependent and requires extensive training and expertise to assess fetal anatomy properly. Most of the sonographic examination time is devoted to acquisition of images, while 'retrieval' and display of diagnostic planes occurs rapidly (essentially instantaneously). In contrast, volumetric sonography has a rapid acquisition phase, but the retrieval and display of relevant diagnostic planes is often time-consuming, tedious and challenging. We propose the term 'intelligent navigation' to refer to a new method of interrogation of a volume dataset whereby identification and selection of key anatomical landmarks allow the system to: 1) generate a geometrical reconstruction of the organ of interest; and 2) automatically navigate, find, extract and display specific diagnostic planes. This is accomplished using operator-independent algorithms that are both predictable and adaptive. Virtual Intelligent Sonographer Assistance (VIS-Assistance®) is a tool that allows operator-independent sonographic navigation and exploration of the surrounding structures in previously identified diagnostic planes. The advantage of intelligent (over manual) navigation in volumetric sonography is the short time required for both acquisition and retrieval and display of diagnostic planes. Intelligent navigation technology automatically realigns the volume, and reorients and standardizes the anatomical position, so that the fetus and the diagnostic planes are consistently displayed in the same manner each time, regardless of the fetal position or the initial orientation. Automatic labeling of anatomical structures, subject orientation and each of the diagnostic planes is also possible. Intelligent navigation technology can operate on conventional computers, and is not dependent on specific ultrasound platforms or on the use of software to perform manual navigation of volume datasets. Diagnostic planes and VIS-Assistance videoclips can be transmitted by telemedicine so that expert consultants can evaluate the images to provide an opinion. The end result is a user-friendly, simple, fast and consistent method of obtaining sonographic images with decreased operator dependency. Intelligent navigation is one approach to improve obstetrical sonography. Published 2015. This article is a U.S. Government work and is in the public domain in the USA. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
Ogawa, Tatsuya; Uchino, Tomohiro; Takahashi, Daisuke; Izumi, Tsuyoshi; Otsuka, Makoto
2012-11-01
In some of drug developments, the amount of bulk drug powder to use in early stages is limited and it is not easy to supply a sufficient drug amount for conventional preparation methods. Therefore, an ultra-small-scale high-shear granulator (less than 5 g) (USG) was developed and applied to small-scale granulation as a pre-formulation. The sample powder consisted of 66.5% lactose, 28.5% microcrystalline cellulose and 5.0% hydroxypropylcellulose. The granules were obtained to agitate 5 g of the sample powder with 1.0 mL of water at 300 rpm for 5 min after pre-powder mixing for 3 min by the USG and the manual hand (HM) methods. The granules were evaluated by the 10% and 90% accumulated particle size and the recoveries of the granules and the powder solid. Median particle size for the USG and the HM methods was 159.2 ± 2.3 and 270.9 ± 14.9 µm, respectively. The USG method had a narrower particle size distribution than those by the HM method. The recovery of the granules by USG was significantly larger than that by the HM method. Characteristics of all of the granules indicated that the USG method could produce higher quality granules within a shorter time than the HM methods.
Conventional drilling versus piezosurgery for implant site preparation: a meta-analysis.
Sendyk, Daniel Isaac; Oliveira, Natacha Kalline; Pannuti, Claudio Mendes; Naclério-Homem, Maria da Graça; Wennerberg, Ann; Zindel Deboni, Maria Cristina
2018-03-27
The aim of this study was to evaluate the evidence of a correlation between the stability of dental implants placed by piezosurgery, compared with implants placed by conventional drilling. An electronic search in MEDLINE, SCOPUS and the Cochrane Library was undertaken until August 2016 and was supplemented by manual searches and by unpublished studies at OpenGray. Only randomized controlled clinical trials that reported implant site preparation with piezosurgery and with conventional drilling were considered eligible for inclusion in this review. Meta-analyses were performed to evaluate the impact of piezosurgery on implant stability. Of 456 references electronically retrieved, 3 were included in the qualitative analysis and quantitative synthesis. The pooled estimates suggest that there is no significant difference between piezosurgery and conventional drilling at baseline (WMD: 2.20; 95% CI: -5.09, 9,49; p = 0.55). At 90 days, the pooled estimates revealed a statistically significant difference (WMD: 3.63; 95% CI: 0.58, 6.67, p = 0.02) favouring piezosurgery. Implant stability is slightly improved when osteotomy was performed by a piezoelectric device. More randomized controlled clinical trials are needed to verify these findings.
Urban Watershed Forestry Manual Part 1: Methods for Increasing Forest Cover in a Watershed
Karen Cappiella; Tom Schueler; Tiffany Wright
2005-01-01
This manual is one in a three-part series on using trees to protect and restore urban watersheds. A brief description of each part follows. Part 1: Methods for Increasing Forest Cover in a Watershed introduces the emerging topic of urban watershed forestry. This part also presents new methods for the watershed planner or forester to systematically measure watershed...
Tomlinson, Mathew James; Pooley, Karen; Simpson, Tracey; Newton, Thomas; Hopkisson, James; Jayaprakasan, Kannamanadias; Jayaprakasan, Rajisha; Naeem, Asad; Pridmore, Tony
2010-04-01
To determine the accuracy and precision of a novel computer-assisted sperm analysis (CASA) system by comparison with existing recommended manual methods. Prospective study using comparative measurements of sperm concentration and motility on latex beads and immotile and motile sperm. Tertiary referral fertility center with strong academic links. Sperm donors and male partners of couples attending for fertility investigations. None. Achievement of Accubead target value for high and low concentration suspensions. Repeatability as demonstrated by coefficients of variation and intraclass correlation coefficients. Correlation and limits of agreement between CASA and manual methods. The CASA measurements of latex beads and sperm concentrations demonstrated a high level of accuracy and repeatability. Repeated Accubead measurements attained the required target value (mean difference from target of 2.61% and 3.71% for high- and low-concentration suspensions, respectively) and were highly reproducible. Limits of agreement analysis suggested that manual and CASA counts compared directly could be deemed to be interchangeable. Manual and CASA motility measurements were highly correlated for grades a, b, and d but could not be deemed to be interchangeable, and manual motility estimates were consistently higher for motile sperm. The novel CASA system was able to provide semen quality measurements for sperm concentration and motility measurements which were at least as reliable as current manual methods. Copyright 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Bouchoucha, Mongia; Akrout, Mouna; Bellali, Hédia; Bouchoucha, Rim; Tarhouni, Fadwa; Mansour, Abderraouf Ben; Zouari, Béchir
2016-01-01
Background Estimation of food portion sizes has always been a challenge in dietary studies on free-living individuals. The aim of this work was to develop and validate a food photography manual to improve the accuracy of the estimated size of consumed food portions. Methods A manual was compiled from digital photos of foods commonly consumed by the Tunisian population. The food was cooked and weighed before taking digital photographs of three portion sizes. The manual was validated by comparing the method of 24-hour recall (using photos) to the reference method [food weighing (FW)]. In both the methods, the comparison focused on food intake amounts as well as nutritional issues. Validity was assessed by Bland–Altman limits of agreement. In total, 31 male and female volunteers aged 9–89 participated in the study. Results We focused on eight food categories and compared their estimated amounts (using the 24-hour recall method) to those actually consumed (using FW). Animal products and sweets were underestimated, whereas pasta, bread, vegetables, fruits, and dairy products were overestimated. However, the difference between the two methods is not statistically significant except for pasta (p<0.05) and dairy products (p<0.05). The coefficient of correlation between the two methods is highly significant, ranging from 0.876 for pasta to 0.989 for dairy products. Nutrient intake calculated for both methods showed insignificant differences except for fat (p<0.001) and dietary fiber (p<0.05). A highly significant correlation was observed between the two methods for all micronutrients. The test agreement highlights the lack of difference between the two methods. Conclusion The difference between the 24-hour recall method using digital photos and the weighing method is acceptable. Our findings indicate that the food photography manual can be a useful tool for quantifying food portion sizes in epidemiological dietary surveys. PMID:27585631
Bouchoucha, Mongia; Akrout, Mouna; Bellali, Hédia; Bouchoucha, Rim; Tarhouni, Fadwa; Mansour, Abderraouf Ben; Zouari, Béchir
2016-01-01
Background Estimation of food portion sizes has always been a challenge in dietary studies on free-living individuals. The aim of this work was to develop and validate a food photography manual to improve the accuracy of the estimated size of consumed food portions. Methods A manual was compiled from digital photos of foods commonly consumed by the Tunisian population. The food was cooked and weighed before taking digital photographs of three portion sizes. The manual was validated by comparing the method of 24-hour recall (using photos) to the reference method [food weighing (FW)]. In both the methods, the comparison focused on food intake amounts as well as nutritional issues. Validity was assessed by Bland-Altman limits of agreement. In total, 31 male and female volunteers aged 9-89 participated in the study. Results We focused on eight food categories and compared their estimated amounts (using the 24-hour recall method) to those actually consumed (using FW). Animal products and sweets were underestimated, whereas pasta, bread, vegetables, fruits, and dairy products were overestimated. However, the difference between the two methods is not statistically significant except for pasta (p<0.05) and dairy products (p<0.05). The coefficient of correlation between the two methods is highly significant, ranging from 0.876 for pasta to 0.989 for dairy products. Nutrient intake calculated for both methods showed insignificant differences except for fat (p<0.001) and dietary fiber (p<0.05). A highly significant correlation was observed between the two methods for all micronutrients. The test agreement highlights the lack of difference between the two methods. Conclusion The difference between the 24-hour recall method using digital photos and the weighing method is acceptable. Our findings indicate that the food photography manual can be a useful tool for quantifying food portion sizes in epidemiological dietary surveys.
Performance test of nutrient control equipment for hydroponic plants
NASA Astrophysics Data System (ADS)
Rahman, Nurhaidar; Kuala, S. I.; Tribowo, R. I.; Anggara, C. E. W.; Susanti, N. D.
2017-11-01
Automatic control equipment has been made for the nutrient content in irrigation water for hydroponic plants. Automatic control equipment with CCT53200E conductivity controller to nutrient content in irrigation water for hydroponic plants, can be used to control the amount of TDS of nutrient solution in the range of TDS numbers that can be set according to the range of TDS requirements for the growth of hydroponically cultivated crops. This equipment can minimize the work time of hydroponic crop cultivators. The equipment measurement range is set between 1260 ppm up to 1610 ppm for spinach plants. Caisim plants were included in this experiment along with spinach plants with a spinach plants TDS range. The average of TDS device is 1450 ppm, while manual (conventional) is 1610 ppm. Nutrient solution in TDS controller has pH 5,5 and temperature 29,2 °C, while manual is pH 5,6 and temperature 31,3 °C. Manually treatment to hydroponic plant crop, yields in an average of 39.6 grams/plant, greater than the yield of spinach plants with TDS control equipment, which is in an average of 24.6 grams / plant. The yield of caisim plants by manual treatment is in an average of 32.3 grams/crop, less than caisim crop yields with TDS control equipment, which is in an average of 49.4 grams/plant.
Goldin-Meadow, Susan
2014-01-01
It is difficult to create spoken forms that can be understood on the spot. But the manual modality, in large part because of its iconic potential, allows us to construct forms that are immediately understood, thus requiring essentially no time to develop. This paper contrasts manual forms for actions produced over 3 time spans—by silent gesturers who are asked to invent gestures on the spot; by homesigners who have created gesture systems over their lifespans; and by signers who have learned a conventional sign language from other signers—and finds that properties of the predicate differ across these time spans. Silent gesturers use location to establish co-reference in the way established sign languages do, but show little evidence of the segmentation sign languages display in motion forms for manner and path, and little evidence of the finger complexity sign languages display in handshapes in predicates representing events. Homesigners, in contrast, not only use location to establish co-reference, but also display segmentation in their motion forms for manner and path and finger complexity in their object handshapes, although they have not yet decreased finger complexity to the levels found in sign languages in their handling handshapes. The manual modality thus allows us to watch language as it grows, offering insight into factors that may have shaped and may continue to shape human language. PMID:25329421
Decking, J; Gerber, A; Kränzlein, J; Meurer, A; Böhm, B; Plitz, W
2004-01-01
We investigated the initial stability of cementless stems implanted with robotic milling and conventional manual broaching. Proximally porous structured stems (G2, ESKA-Implants, Luebeck, Germany) were implanted into synthetic femora. In one group, the femoral cavity was prepared by a CT-based robot (CASPAR, URS-Ortho, Germany) with a high-speed milling head. In the other group, femora were rasped manually with broaches. The broaches had 1 mm proximal press-fit, the robotic cavities 1.5 mm. The implants were exposed to 15 000 loading cycles with 1 000 +/- 500 N. The direction of forces on the implant head were chosen to simulate stair climbing. Internal rotation and translation (caudal, dorsal and lateral) of the implants were measured by linear transducers. The robotic group showed significantly less reversible motion regarding translation in caudal, dorsal and lateral directions. The standard deviations of implant motions were smaller in the robotic group. Using robotic preparation of the femur, initial stability was higher and more consistent than with manual broaching, but differences in undersizing of the cavities created in the femur in relation to the implant may have contributed to these differences for the most part. In-vitro-loading experiments focusing on femoral cavities with varying press-fits are recommended before the introduction of new implants or operating procedures.
User's Manual for FEM-BEM Method. 1.0
NASA Technical Reports Server (NTRS)
Butler, Theresa; Deshpande, M. D. (Technical Monitor)
2002-01-01
A user's manual for using FORTRAN code to perform electromagnetic analysis of arbitrarily shaped material cylinders using a hybrid method that combines the finite element method (FEM) and the boundary element method (BEM). In this method, the material cylinder is enclosed by a fictitious boundary and the Maxwell's equations are solved by FEM inside the boundary and by BEM outside the boundary. The electromagnetic scattering on several arbitrarily shaped material cylinders using this FORTRAN code is computed to as examples.
Is STAPLE algorithm confident to assess segmentation methods in PET imaging?
NASA Astrophysics Data System (ADS)
Dewalle-Vignion, Anne-Sophie; Betrouni, Nacim; Baillet, Clio; Vermandel, Maximilien
2015-12-01
Accurate tumor segmentation in [18F]-fluorodeoxyglucose positron emission tomography is crucial for tumor response assessment and target volume definition in radiation therapy. Evaluation of segmentation methods from clinical data without ground truth is usually based on physicians’ manual delineations. In this context, the simultaneous truth and performance level estimation (STAPLE) algorithm could be useful to manage the multi-observers variability. In this paper, we evaluated how this algorithm could accurately estimate the ground truth in PET imaging. Complete evaluation study using different criteria was performed on simulated data. The STAPLE algorithm was applied to manual and automatic segmentation results. A specific configuration of the implementation provided by the Computational Radiology Laboratory was used. Consensus obtained by the STAPLE algorithm from manual delineations appeared to be more accurate than manual delineations themselves (80% of overlap). An improvement of the accuracy was also observed when applying the STAPLE algorithm to automatic segmentations results. The STAPLE algorithm, with the configuration used in this paper, is more appropriate than manual delineations alone or automatic segmentations results alone to estimate the ground truth in PET imaging. Therefore, it might be preferred to assess the accuracy of tumor segmentation methods in PET imaging.
Is STAPLE algorithm confident to assess segmentation methods in PET imaging?
Dewalle-Vignion, Anne-Sophie; Betrouni, Nacim; Baillet, Clio; Vermandel, Maximilien
2015-12-21
Accurate tumor segmentation in [18F]-fluorodeoxyglucose positron emission tomography is crucial for tumor response assessment and target volume definition in radiation therapy. Evaluation of segmentation methods from clinical data without ground truth is usually based on physicians' manual delineations. In this context, the simultaneous truth and performance level estimation (STAPLE) algorithm could be useful to manage the multi-observers variability. In this paper, we evaluated how this algorithm could accurately estimate the ground truth in PET imaging. Complete evaluation study using different criteria was performed on simulated data. The STAPLE algorithm was applied to manual and automatic segmentation results. A specific configuration of the implementation provided by the Computational Radiology Laboratory was used. Consensus obtained by the STAPLE algorithm from manual delineations appeared to be more accurate than manual delineations themselves (80% of overlap). An improvement of the accuracy was also observed when applying the STAPLE algorithm to automatic segmentations results. The STAPLE algorithm, with the configuration used in this paper, is more appropriate than manual delineations alone or automatic segmentations results alone to estimate the ground truth in PET imaging. Therefore, it might be preferred to assess the accuracy of tumor segmentation methods in PET imaging.
Extent of agreement between the body fluid model of Sysmex XN-20 and the manual microscopy method.
Huang, Wei-Hua; Lu, Lin-Peng; Wu, Kang; Guo, Fang-Yu; Guo, Jie; Yu, Jing-Long; Zhou, Dao-Yin; Sun, Yi; Deng, An-Mei
2017-09-01
Although the correlations concerning cellular component analysis between the Sysmex XN-20 body fluid (BF) model and manual microscopy have been investigated by several studies, the extent of agreement between these two methods has not been investigated. A total of 90 BF samples were prospectively collected and analyzed using the Sysmex XN-20 BF model and microscopy. The extent of agreement between these two methods was evaluated using the Bland-Altman approach. Receiver operating characteristic (ROC) curve analysis was employed to evaluate the diagnostic accuracy of high-fluorescence (HF) BF cells for malignant diseases. The agreements of white blood cell (WBC), red blood cell (RBC), and percentages of neutrophils, lymphocytes, and monocytes between the Sysmex XN-20 BF model and manual microscopy were imperfect. The areas under the ROC curves for absolute and relative HF cells were 0.67 (95% confidence interval [CI]: 0.56-0.78) and 0.60 (95% CI: 0.48-0.72), respectively. Due to the Sysmex XN-20 BF model's imperfect agreement with manual microscopy and its weak diagnostic accuracy for malignant diseases, the current evidence does not support replacing manual microscopy with this model in clinical practice. © 2016 Wiley Periodicals, Inc.
Economic and workflow analysis of a blood bank automated system.
Shin, Kyung-Hwa; Kim, Hyung Hoi; Chang, Chulhun L; Lee, Eun Yup
2013-07-01
This study compared the estimated costs and times required for ABO/Rh(D) typing and unexpected antibody screening using an automated system and manual methods. The total cost included direct and labor costs. Labor costs were calculated on the basis of the average operator salaries and unit values (minutes), which was the hands-on time required to test one sample. To estimate unit values, workflows were recorded on video, and the time required for each process was analyzed separately. The unit values of ABO/Rh(D) typing using the manual method were 5.65 and 8.1 min during regular and unsocial working hours, respectively. The unit value was less than 3.5 min when several samples were tested simultaneously. The unit value for unexpected antibody screening was 2.6 min. The unit values using the automated method for ABO/Rh(D) typing, unexpected antibody screening, and both simultaneously were all 1.5 min. The total cost of ABO/Rh(D) typing of only one sample using the automated analyzer was lower than that of testing only one sample using the manual technique but higher than that of testing several samples simultaneously. The total cost of unexpected antibody screening using an automated analyzer was less than that using the manual method. ABO/Rh(D) typing using an automated analyzer incurs a lower unit value and cost than that using the manual technique when only one sample is tested at a time. Unexpected antibody screening using an automated analyzer always incurs a lower unit value and cost than that using the manual technique.
Lehmann, R; Gallert, C; Roddelkopf, T; Junginger, S; Wree, A; Thurow, K
2016-08-01
Cancer diseases are a common problem of the population caused by age and increased harmful environmental influences. Herein, new therapeutic strategies and compound screenings are necessary. The regular 2D cultivation has to be replaced by three dimensional cell culturing (3D) for better simulation of in vivo conditions. The 3D cultivation with alginate matrix is an appropriate method for encapsulate cells to form cancer constructs. The automated manufacturing of alginate beads might be an ultimate method for large-scaled manufacturing constructs similar to cancer tissue. The aim of this study was the integration of full automated systems for the production, cultivation and screening of 3D cell cultures. We compared the automated methods with the regular manual processes. Furthermore, we investigated the influence of antibiotics on these 3D cell culture systems. The alginate beads were formed by automated and manual procedures. The automated steps were processes by the Biomek(®) Cell Workstation (celisca, Rostock, Germany). The proliferation and toxicity were manually and automatically evaluated at day 14 and 35 of cultivation. The results visualized an accumulation and expansion of cell aggregates over the period of incubation. However, the proliferation and toxicity were faintly and partly significantly decreased on day 35 compared to day 14. The comparison of the manual and automated methods displayed similar results. We conclude that the manual production process could be replaced by the automation. Using automation, 3D cell cultures can be produced in industrial scale and improve the drug development and screening to treat serious illnesses like cancer.
Tempest, Nicola; McGuinness, Naomi; Lane, Steven; Hapangama, Dharani K.
2017-01-01
Objective To evaluate the neonatal and maternal outcomes associated with successful operative vaginal births assisted by manual rotation. Design Prospective and retrospective observational study. Setting Delivery suite in a tertiary referral teaching hospital in England. Population A cohort of 2,426 consecutive operative births, in the second stage of labour, complicated with malposition of the fetal head during 2006–2013. Methods Outcomes of all births successfully assisted by manual rotation followed by direct traction instruments were compared with other methods of operative birth for fetal malposition in the second stage of labour (rotational ventouse, Kielland forceps and caesarean section). Main outcome measures Associated neonatal outcomes (admission to the special care baby unit, low cord pH, low Apgar and shoulder dystocia) and maternal outcomes (massive obstetric haemorrhage (blood loss of >1500ml) and obstetric anal sphincter injury). Results Births successfully assisted with manual rotation followed by direct traction instruments, resulted in 10% (36/346) of the babies being admitted to the Special Care Baby Unit, 4.9% (17/349) shoulder dystocia, 2% (7/349) massive obstetric haemorrhage and 1.7% (6/349) obstetric anal sphincter injury, similar to other methods of rotational births. Conclusions Adverse neonatal and maternal outcomes associated with successful manual rotations followed by direct traction instruments were comparable to traditional methods of operative births. There is an urgent need to standardise the practice (guidance, training) and documentation of manual rotation followed by direct traction instrumental deliveries that will enable assessment of its efficacy and the absolute safety in achieving a vaginal birth. PMID:28489924
Microbial ecology laboratory procedures manual NASA/MSFC
NASA Technical Reports Server (NTRS)
Huff, Timothy L.
1990-01-01
An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.
Laparoscopic approach to incarcerated inguinal hernia in children.
Kaya, Mete; Hückstedt, Thomas; Schier, Felix
2006-03-01
The purpose of this study was to describe the laparoscopic approach to incarcerated inguinal hernia in children. After unsuccessful manual reduction, 29 patients (aged 3 weeks to 7 years; median, 10 weeks; 44 boys, 15 girls) with incarcerated inguinal hernia underwent immediate laparoscopy. The hernial content was reduced in a combined technique of external manual pressure and internal pulling by forceps. The bowel was inspected, and the hernia was repaired. In all patients, the procedure was successful. No conversion to the open approach was required. Immediate laparoscopic herniorrhaphy in the same session was added. No complications occurred. Laparoscopy allowed for simultaneous reduction under direct visual control, inspection of the incarcerated organ, and definitive repair of the hernia. Technically, it appears easier than the conventional approach because of the internal inguinal ring being widened by intraabdominal carbon dioxide insufflation. The hospital stay is shorter.
School-Based Prevention of Bullying and Relational Aggression in Adolescence: The Fairplayer.manual
ERIC Educational Resources Information Center
Scheithauer, Herbert; Hess, Markus; Schultze-Krumbholz, Anja; Bull, Heike Dele
2012-01-01
The fairplayer.manual is a school-based program to prevent bullying. The program consists of fifteen to seventeen consecutive ninety-minute lessons using cognitive-behavioral methods, methods targeting group norms and group dynamics, and discussions on moral dilemmas. Following a two-day training session, teachers, together with skilled…
An extended Kalman filter for mouse tracking.
Choi, Hongjun; Kim, Mingi; Lee, Onseok
2018-05-19
Animal tracking is an important tool for observing behavior, which is useful in various research areas. Animal specimens can be tracked using dynamic models and observation models that require several types of data. Tracking mouse has several barriers due to the physical characteristics of the mouse, their unpredictable movement, and cluttered environments. Therefore, we propose a reliable method that uses a detection stage and a tracking stage to successfully track mouse. The detection stage detects the surface area of the mouse skin, and the tracking stage implements an extended Kalman filter to estimate the state variables of a nonlinear model. The changes in the overall shape of the mouse are tracked using an oval-shaped tracking model to estimate the parameters for the ellipse. An experiment is conducted to demonstrate the performance of the proposed tracking algorithm using six video images showing various types of movement, and the ground truth values for synthetic images are compared to the values generated by the tracking algorithm. A conventional manual tracking method is also applied to compare across eight experimenters. Furthermore, the effectiveness of the proposed tracking method is also demonstrated by applying the tracking algorithm with actual images of mouse. Graphical abstract.
A Vision-Based Counting and Recognition System for Flying Insects in Intelligent Agriculture.
Zhong, Yuanhong; Gao, Junyuan; Lei, Qilun; Zhou, Yao
2018-05-09
Rapid and accurate counting and recognition of flying insects are of great importance, especially for pest control. Traditional manual identification and counting of flying insects is labor intensive and inefficient. In this study, a vision-based counting and classification system for flying insects is designed and implemented. The system is constructed as follows: firstly, a yellow sticky trap is installed in the surveillance area to trap flying insects and a camera is set up to collect real-time images. Then the detection and coarse counting method based on You Only Look Once (YOLO) object detection, the classification method and fine counting based on Support Vector Machines (SVM) using global features are designed. Finally, the insect counting and recognition system is implemented on Raspberry PI. Six species of flying insects including bee, fly, mosquito, moth, chafer and fruit fly are selected to assess the effectiveness of the system. Compared with the conventional methods, the test results show promising performance. The average counting accuracy is 92.50% and average classifying accuracy is 90.18% on Raspberry PI. The proposed system is easy-to-use and provides efficient and accurate recognition data, therefore, it can be used for intelligent agriculture applications.
A Vision-Based Counting and Recognition System for Flying Insects in Intelligent Agriculture
Zhong, Yuanhong; Gao, Junyuan; Lei, Qilun; Zhou, Yao
2018-01-01
Rapid and accurate counting and recognition of flying insects are of great importance, especially for pest control. Traditional manual identification and counting of flying insects is labor intensive and inefficient. In this study, a vision-based counting and classification system for flying insects is designed and implemented. The system is constructed as follows: firstly, a yellow sticky trap is installed in the surveillance area to trap flying insects and a camera is set up to collect real-time images. Then the detection and coarse counting method based on You Only Look Once (YOLO) object detection, the classification method and fine counting based on Support Vector Machines (SVM) using global features are designed. Finally, the insect counting and recognition system is implemented on Raspberry PI. Six species of flying insects including bee, fly, mosquito, moth, chafer and fruit fly are selected to assess the effectiveness of the system. Compared with the conventional methods, the test results show promising performance. The average counting accuracy is 92.50% and average classifying accuracy is 90.18% on Raspberry PI. The proposed system is easy-to-use and provides efficient and accurate recognition data, therefore, it can be used for intelligent agriculture applications. PMID:29747429
Optimal wavelet transform for the detection of microaneurysms in retina photographs.
Quellec, Gwénolé; Lamard, Mathieu; Josselin, Pierre Marie; Cazuguel, Guy; Cochener, Béatrice; Roux, Christian
2008-09-01
In this paper, we propose an automatic method to detect microaneurysms in retina photographs. Microaneurysms are the most frequent and usually the first lesions to appear as a consequence of diabetic retinopathy. So, their detection is necessary for both screening the pathology and follow up (progression measurement). Automating this task, which is currently performed manually, would bring more objectivity and reproducibility. We propose to detect them by locally matching a lesion template in subbands of wavelet transformed images. To improve the method performance, we have searched for the best adapted wavelet within the lifting scheme framework. The optimization process is based on a genetic algorithm followed by Powell's direction set descent. Results are evaluated on 120 retinal images analyzed by an expert and the optimal wavelet is compared to different conventional mother wavelets. These images are of three different modalities: there are color photographs, green filtered photographs, and angiographs. Depending on the imaging modality, microaneurysms were detected with a sensitivity of respectively 89.62%, 90.24%, and 93.74% and a positive predictive value of respectively 89.50%, 89.75%, and 91.67%, which is better than previously published methods.