Sample records for conventional modal testing

  1. Using inertial measurement units originally developed for biomechanics for modal testing of civil engineering structures

    NASA Astrophysics Data System (ADS)

    Hester, David; Brownjohn, James; Bocian, Mateusz; Xu, Yan; Quattrone, Antonino

    2018-05-01

    This paper explores the use of wireless Inertial Measurement Units (IMU) originally developed for bio-mechanical research applications for modal testing of civil engineering infrastructure. Due to their biomechanics origin, these devices combine a triaxial accelerometer with gyroscopes and magnetometers for orientation, as well as on board data logging capability and wireless communication for optional data streaming and to coordinate synchronisation with other IMUs in a network. The motivation for application to civil structures is that their capabilities and simple operating procedures make them suitable for modal testing of many types of civil infrastructure of limited dimension including footbridges and floors while also enabling recovering of dynamic forces generated and applied to structures by moving humans. To explore their capabilities in civil applications, the IMUs are evaluated through modal tests on three different structures with increasing challenge of spatial and environmental complexity. These are, a full-scale floor mock-up in a laboratory, a short span road bridge and a seven story office tower. For each case, the results from the IMUs are compared with those from a conventional wired system to identify the limitations. The main conclusion is that the relatively high noise floor and limited communication range will not be a serious limitation in the great majority of typical civil modal test applications where convenient operation is a significant advantage over conventional wired systems.

  2. Development and evaluation of the impulse transfer function technique

    NASA Technical Reports Server (NTRS)

    Mantus, M.

    1972-01-01

    The development of the test/analysis technique known as the impulse transfer function (ITF) method is discussed. This technique, when implemented with proper data processing systems, should become a valuable supplement to conventional dynamic testing and analysis procedures that will be used in the space shuttle development program. The method can relieve many of the problems associated with extensive and costly testing of the shuttle for transient loading conditions. In addition, the time history information derived from impulse testing has the potential for being used to determine modal data for the structure under investigation. The technique could be very useful in determining the time-varying modal characteristics of structures subjected to thermal transients, where conventional mode surveys are difficult to perform.

  3. Bayesian operational modal analysis with asynchronous data, part I: Most probable value

    NASA Astrophysics Data System (ADS)

    Zhu, Yi-Chen; Au, Siu-Kui

    2018-01-01

    In vibration tests, multiple sensors are used to obtain detailed mode shape information about the tested structure. Time synchronisation among data channels is required in conventional modal identification approaches. Modal identification can be more flexibly conducted if this is not required. Motivated by the potential gain in feasibility and economy, this work proposes a Bayesian frequency domain method for modal identification using asynchronous 'output-only' ambient data, i.e. 'operational modal analysis'. It provides a rigorous means for identifying the global mode shape taking into account the quality of the measured data and their asynchronous nature. This paper (Part I) proposes an efficient algorithm for determining the most probable values of modal properties. The method is validated using synthetic and laboratory data. The companion paper (Part II) investigates identification uncertainty and challenges in applications to field vibration data.

  4. Accuracy and Landmark Error Calculation Using Cone-Beam Computed Tomography–Generated Cephalograms

    PubMed Central

    Grauer, Dan; Cevidanes, Lucia S. H.; Styner, Martin A.; Heulfe, Inam; Harmon, Eric T.; Zhu, Hongtu; Proffit, William R.

    2010-01-01

    Objective To evaluate systematic differences in landmark position between cone-beam computed tomography (CBCT)–generated cephalograms and conventional digital cephalograms and to estimate how much variability should be taken into account when both modalities are used within the same longitudinal study. Materials and Methods Landmarks on homologous cone-beam computed tomographic–generated cephalograms and conventional digital cephalograms of 46 patients were digitized, registered, and compared via the Hotelling T2 test. Results There were no systematic differences between modalities in the position of most landmarks. Three landmarks showed statistically significant differences but did not reach clinical significance. A method for error calculation while combining both modalities in the same individual is presented. Conclusion In a longitudinal follow-up for assessment of treatment outcomes and growth of one individual, the error due to the combination of the two modalities might be larger than previously estimated. PMID:19905853

  5. Using Business Simulations as Authentic Assessment Tools

    ERIC Educational Resources Information Center

    Neely, Pat; Tucker, Jan

    2012-01-01

    New modalities for assessing student learning exist as a result of advances in computer technology. Conventional measurement practices have been transformed into computer based testing. Although current testing replicates assessment processes used in college classrooms, a greater opportunity exists to use computer technology to create authentic…

  6. Defect Localization Capabilities of a Global Detection Scheme: Spatial Pattern Recognition Using Full-field Vibration Test Data in Plates

    NASA Technical Reports Server (NTRS)

    Saleeb, A. F.; Prabhu, M.; Arnold, S. M. (Technical Monitor)

    2002-01-01

    Recently, a conceptually simple approach, based on the notion of defect energy in material space has been developed and extensively studied (from the theoretical and computational standpoints). The present study focuses on its evaluation from the viewpoint of damage localization capabilities in case of two-dimensional plates; i.e., spatial pattern recognition on surfaces. To this end, two different experimental modal test results are utilized; i.e., (1) conventional modal testing using (white noise) excitation and accelerometer-type sensors and (2) pattern recognition using Electronic speckle pattern interferometry (ESPI), a full field method capable of analyzing the mechanical vibration of complex structures. Unlike the conventional modal testing technique (using contacting accelerometers), these emerging ESPI technologies operate in a non-contacting mode, can be used even under hazardous conditions with minimal or no presence of noise and can simultaneously provide measurements for both translations and rotations. Results obtained have clearly demonstrated the robustness and versatility of the global NDE scheme developed. The vectorial character of the indices used, which enabled the extraction of distinct patterns for localizing damages proved very useful. In the context of the targeted pattern recognition paradigm, two algorithms were developed for the interrogation of test measurements; i.e., intensity contour maps for the damaged index, and the associated defect energy vector field plots.

  7. Simulating flight boundary conditions for orbiter payload modal survey

    NASA Technical Reports Server (NTRS)

    Chung, Y. T.; Sernaker, M. L.; Peebles, J. H.

    1993-01-01

    An approach to simulate the characteristics of the payload/orbiter interfaces for the payload modal survey was developed. The flexure designed for this approach is required to provide adequate stiffness separation in the free and constrained interface degrees of freedom to closely resemble the flight boundary condition. Payloads will behave linearly and demonstrate similar modal effective mass distribution and load path as the flight if the flexure fixture is used for the payload modal survey. The potential non-linearities caused by the trunnion slippage during the conventional fixed base modal survey may be eliminated. Consequently, the effort to correlate the test and analysis models can be significantly reduced. An example is given to illustrate the selection and the sensitivity of the flexure stiffness. The advantages of using flexure fixtures for the modal survey and for the analytical model verification are also demonstrated.

  8. [Comparative Study of Patient Identifications for Conventional and Portable Chest Radiographs Utilizing ROC Analysis].

    PubMed

    Kawashima, Hiroki; Hayashi, Norio; Ohno, Naoki; Matsuura, Yukihiro; Sanada, Shigeru

    2015-08-01

    To evaluate the patient identification ability of radiographers, previous and current chest radiographs were assessed with observer study utilizing a receiver operating characteristics (ROCs) analysis. This study included portable and conventional chest radiographs from 43 same and 43 different patients. The dataset used in this study was divided into the three following groups: (1) a pair of portable radiographs, (2) a pair of conventional radiographs, and (3) a combination of each type of radiograph. Seven observers participated in this ROC study, which aimed to identify same or different patients, using these datasets. ROC analysis was conducted to calculate the average area under ROC curve obtained by each observer (AUCave), and a statistical test was performed using the multi-reader multi-case method. Comparable results were obtained with pairs of portable (AUCave: 0.949) and conventional radiographs (AUCave: 0.951). In a comparison between the same modality, there were no significant differences. In contrast, the ability to identify patients by comparing a portable and conventional radiograph (AUCave: 0.873) was lower than with the matching datasets (p=0.002 and p=0.004, respectively). In conclusion, the use of different imaging modalities reduces radiographers' ability to identify their patients.

  9. Comparison of linear measurements between CBCT orthogonally synthesized cephalograms and conventional cephalograms

    PubMed Central

    Yang, S; Liu, D G

    2014-01-01

    Objectives: The purposes of the study are to investigate the consistency of linear measurements between CBCT orthogonally synthesized cephalograms and conventional cephalograms and to evaluate the influence of different magnifications on these comparisons based on a simulation algorithm. Methods: Conventional cephalograms and CBCT scans were taken on 12 dry skulls with spherical metal markers. Orthogonally synthesized cephalograms were created from CBCT data. Linear parameters on both cephalograms were measured via Photoshop CS v. 5.0 (Adobe® Systems, San Jose, CA), named measurement group (MG). Bland–Altman analysis was utilized to assess the agreement of two imaging modalities. Reproducibility was investigated using paired t-test. By a specific mathematical programme “cepha”, corresponding linear parameters [mandibular corpus length (Go-Me), mandibular ramus length (Co-Go), posterior facial height (Go-S)] on these two types of cephalograms were calculated, named simulation group (SG). Bland–Altman analysis was used to assess the agreement between MG and SG. Simulated linear measurements with varying magnifications were generated based on “cepha” as well. Bland–Altman analysis was used to assess the agreement of simulated measurements between two modalities. Results: Bland–Altman analysis suggested the agreement between measurements on conventional cephalograms and orthogonally synthesized cephalograms, with a mean bias of 0.47 mm. Comparison between MG and SG showed that the difference did not reach clinical significance. The consistency between simulated measurements of both modalities with four different magnifications was demonstrated. Conclusions: Normative data of conventional cephalograms could be used for CBCT orthogonally synthesized cephalograms during this transitional period. PMID:25029593

  10. Potential and Limitations of the Modal Characterization of a Spacecraft Bus Structure by Means of Active Structure Elements

    NASA Technical Reports Server (NTRS)

    Grillenbeck, Anton M.; Dillinger, Stephan A.; Elliott, Kenny B.

    1998-01-01

    Theoretical and experimental studies have been performed to investigate the potential and limitations of the modal characterization of a typical spacecraft bus structure by means of active structure elements. The aim of these studies has been test and advance tools for performing an accurate on-orbit modal identification which may be characterized by the availability of a generally very limited test instrumentation, autonomous excitation capabilities by active structure elements and a zero-g environment. The NASA LARC CSI Evolutionary Testbed provided an excellent object for the experimental part of this study program. The main subjects of investigation were: (1) the selection of optimum excitation and measurement to unambiguously identify modes of interest; (2) the applicability of different types of excitation means with focus on active structure elements; and (3) the assessment of the modal identification potential of different types of excitation functions and modal analysis tools. Conventional as well as dedicated modal analysis tools were applied to determine modal parameters and mode shapes. The results will be presented and discussed based on orthogonality checks as well as on suitable indicators for the quality of the acquired modes with respect to modal purity. In particular, the suitability for modal analysis of the acquired frequency response functions as obtained by excitation with active structure elements will be demonstrated with the help of reciprocity checks. Finally, the results will be summarized in a procedure to perform an on-orbit modal identification, including an indication of limitation to be observed.

  11. Contrast-Enhanced Ultrasound as a New Investigative Tool in Diagnostic Imaging of Muscle Injuries-A Pilot Study Evaluating Conventional Ultrasound, CEUS, and Findings in MRI.

    PubMed

    Hotfiel, Thilo; Heiss, Rafael; Swoboda, Bernd; Kellermann, Marion; Gelse, Kolja; Grim, Casper; Strobel, Deike; Wildner, Dane

    2018-07-01

    To emphasize the diagnostic value of contrast-enhanced ultrasound (CEUS) in the imaging of muscle injuries with different degrees of severity by comparing findings to established imaging modalities such as conventional ultrasound and magnetic resonance imaging (MRI). Case series. Institutional study. Conventional ultrasound and CEUS were performed in the Department of Internal Medicine. Magnetic resonance imaging was carried out in the Department of Radiology within the Magnetom Avanto 1.5T and Magnetom Skyra fit 3T (Siemens Healthineers, Erlangen, Germany) and in the Institution of Imaging Diagnostics and Therapy (Magnetom Avanto 1.5T; Siemens, Erlangen, Germany). Fifteen patients who underwent an acute muscle injury were recruited. The appearance and detectable size of muscle injuries were compared between each imaging modality. The injuries were assessed by 3 independent observers and blinded between imaging modalities. All 15 injuries were identified on MRI and CEUS, whereas 10 injuries showed abnormalities in conventional ultrasound. The determination and measurement revealed significant differences between conventional ultrasound and CEUS depending on injury severity. Contrast-enhanced ultrasound revealed an impairment of microcirculation in grade I lesions (corresponding to intramuscular edema observed in MRI), which was not detectable using conventional ultrasound. Our results indicate that performing CEUS seems to be a sensitive additional diagnostic modality in the early assessment of muscle injuries. Our results highlight the advantages of CEUS in the imaging of low-grade lesions when compared with conventional ultrasound, as this was the more accurate modality for identifying intramuscular edema.

  12. Conventional versus ultrasound-assisted liposuction in gynaecomastia surgery: a 13-year review.

    PubMed

    Wong, Kai Yuen; Malata, Charles M

    2014-07-01

    Numerous surgical techniques exist for gynaecomastia treatment. Although ultrasound-assisted liposuction (UAL) is thought to be more effective than conventional liposuction, to date there remains no objective and direct comparison of the two modalities. Hence, a comparative study was performed of a single surgeon's experience over 13 years using two definitive parameters, namely intraoperative conversion to open excision and postoperative revisional surgery rates. All gynaecomastia patients treated with UAL or conventional liposuction (1999-2012) were retrospectively studied. UAL was only available in the private sector and was used for all such patients with no other selection or exclusion criteria. A total of 219 patients (384 breasts) with a mean age of 29 years (range 12-74) were evaluated. UAL was utilised in 24% of breasts (47 patients, 91 breasts). Compared with conventional liposuction, UAL had significantly lower rates of intraoperative conversion to open excision (25% vs. 39%; p<0.05) and postoperative revision (2% vs. 19%; p<0.001) using Fisher's exact test. The haematoma rate for each technique was 1%. UAL is a more effective treatment modality for gynaecomastia than conventional liposuction as determined by intraoperative conversion to open surgery and subsequent need for revision. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Modal parameter identification using the log decrement method and band-pass filters

    NASA Astrophysics Data System (ADS)

    Liao, Yabin; Wells, Valana

    2011-10-01

    This paper presents a time-domain technique for identifying modal parameters of test specimens based on the log-decrement method. For lightly damped multidegree-of-freedom or continuous systems, the conventional method is usually restricted to identification of fundamental-mode parameters only. Implementation of band-pass filters makes it possible for the proposed technique to extract modal information of higher modes. The method has been applied to a polymethyl methacrylate (PMMA) beam for complex modulus identification in the frequency range 10-1100 Hz. Results compare well with those obtained using the Least Squares method, and with those previously published in literature. Then the accuracy of the proposed method has been further verified by experiments performed on a QuietSteel specimen with very low damping. The method is simple and fast. It can be used for a quick estimation of the modal parameters, or as a complementary approach for validation purposes.

  14. Finite Element Model Development and Validation for Aircraft Fuselage Structures

    NASA Technical Reports Server (NTRS)

    Buehrle, Ralph D.; Fleming, Gary A.; Pappa, Richard S.; Grosveld, Ferdinand W.

    2000-01-01

    The ability to extend the valid frequency range for finite element based structural dynamic predictions using detailed models of the structural components and attachment interfaces is examined for several stiffened aircraft fuselage structures. This extended dynamic prediction capability is needed for the integration of mid-frequency noise control technology. Beam, plate and solid element models of the stiffener components are evaluated. Attachment models between the stiffener and panel skin range from a line along the rivets of the physical structure to a constraint over the entire contact surface. The finite element models are validated using experimental modal analysis results. The increased frequency range results in a corresponding increase in the number of modes, modal density and spatial resolution requirements. In this study, conventional modal tests using accelerometers are complemented with Scanning Laser Doppler Velocimetry and Electro-Optic Holography measurements to further resolve the spatial response characteristics. Whenever possible, component and subassembly modal tests are used to validate the finite element models at lower levels of assembly. Normal mode predictions for different finite element representations of components and assemblies are compared with experimental results to assess the most accurate techniques for modeling aircraft fuselage type structures.

  15. Integrative and complementary therapies for patients with advanced cancer.

    PubMed

    Marchand, Lucille

    2014-07-01

    In integrative medicine, well-being is emphasized, and in palliative care, quality of life (QOL) is a similar concept or goal. Both can occur despite advanced cancer. Integrative medicine serves to combine the best of alternative, complementary and conventional therapies to optimize well-being and QOL, whether or not a person is at the end of their life. When integrative medicine is combined with palliative care modalities, the toolbox to provide symptom control and well-being or QOL is increased or broadened. Palliative care and integrative medicine are best provided early in the trajectory of illness such as cancer, and increase in amount as the illness progresses toward end of life. In cancer care, symptoms of the cancer, as well as symptoms produced by cancer therapies, are addressed with conventional and integrative therapies. Goals of care change as the disease progresses, and a patient's unique situation creates a different balance of integrative and conventional therapies. Integrative therapies such as music, aromatherapy, and massage might appeal to more patients than more specific, less common integrative therapies that might be more expensive, or seem more unusual such as Ayurvedic medicine and energy modalities. Each person may be drawn to different integrative modalities depending on factors such as cultural traditions, beliefs, lifestyle, internet information, advice from family and friends, books, etc. This review focuses on how integrative and complementary modalities can be included in comprehensive palliative care for patients with advanced malignancies. Nutrition and movement, often neglected in conventional treatment strategies, will also be included in the larger context of integrative and palliative modalities. Both conventional and integrative modalities in palliative care help patients live with empowerment, hope, and well-being no matter how long their lives last. A comprehensive review of all integrative and complementary therapies is impossible given the enormous diversity in this area. This review will concentrate on modalities such as nutrition, movement, music, aromatherapy, massage, select supplements, and acupuncture that have been researched in cancer survivors. Many of these modalities are quite effective for a number of symptoms in palliative care and have been studied in non-cancer populations. Resources for further study will also be included.

  16. Breakthroughs in modern cancer therapy and elusive cardiotoxicity: Critical research‐practice gaps, challenges, and insights

    PubMed Central

    Li, Jin; Kros, Johan M

    2017-01-01

    Abstract To date, five cancer treatment modalities have been defined. The three traditional modalities of cancer treatment are surgery, radiotherapy, and conventional chemotherapy, and the two modern modalities include molecularly targeted therapy (the fourth modality) and immunotherapy (the fifth modality). The cardiotoxicity associated with conventional chemotherapy and radiotherapy is well known. Similar adverse cardiac events are resurging with the fourth modality. Aside from the conventional and newer targeted agents, even the most newly developed, immune‐based therapeutic modalities of anticancer treatment (the fifth modality), e.g., immune checkpoint inhibitors and chimeric antigen receptor (CAR) T‐cell therapy, have unfortunately led to potentially lethal cardiotoxicity in patients. Cardiac complications represent unresolved and potentially life‐threatening conditions in cancer survivors, while effective clinical management remains quite challenging. As a consequence, morbidity and mortality related to cardiac complications now threaten to offset some favorable benefits of modern cancer treatments in cancer‐related survival, regardless of the oncologic prognosis. This review focuses on identifying critical research‐practice gaps, addressing real‐world challenges and pinpointing real‐time insights in general terms under the context of clinical cardiotoxicity induced by the fourth and fifth modalities of cancer treatment. The information ranges from basic science to clinical management in the field of cardio‐oncology and crosses the interface between oncology and onco‐pharmacology. The complexity of the ongoing clinical problem is addressed at different levels. A better understanding of these research‐practice gaps may advance research initiatives on the development of mechanism‐based diagnoses and treatments for the effective clinical management of cardiotoxicity. PMID:28862319

  17. Dynamic characteristics of a wind turbine blade using 3D digital image correlation

    NASA Astrophysics Data System (ADS)

    Baqersad, Javad; Carr, Jennifer; Lundstrom, Troy; Niezrecki, Christopher; Avitabile, Peter; Slattery, Micheal

    2012-04-01

    Digital image correlation (DIC) has been becoming increasingly popular as a means to perform structural health monitoring because of its full-field, non-contacting measurement ability. In this paper, 3D DIC techniques are used to identify the mode shapes of a wind turbine blade. The blade containing a handful of optical targets is excited at different frequencies using a shaker as well as a pluck test. The response is recorded using two PHOTRON™ high speed cameras. Time domain data is transferred to the frequency domain to extract mode shapes and natural frequencies using an Operational Modal Approach. A finite element model of the blade is also used to compare the mode shapes. Furthermore, a modal hammer impact test is performed using a more conventional approach with an accelerometer. A comparison of mode shapes from the photogrammetric, finite element, and impact test approaches are presented to show the accuracy of the DIC measurement approach.

  18. Operational modal analysis applied to the concert harp

    NASA Astrophysics Data System (ADS)

    Chomette, B.; Le Carrou, J.-L.

    2015-05-01

    Operational modal analysis (OMA) methods are useful to extract modal parameters of operating systems. These methods seem to be particularly interesting to investigate the modal basis of string instruments during operation to avoid certain disadvantages due to conventional methods. However, the excitation in the case of string instruments is not optimal for OMA due to the presence of damped harmonic components and low noise in the disturbance signal. Therefore, the present study investigates the least-square complex exponential (LSCE) and the modified least-square complex exponential methods in the case of a string instrument to identify modal parameters of the instrument when it is played. The efficiency of the approach is experimentally demonstrated on a concert harp excited by some of its strings and the two methods are compared to a conventional modal analysis. The results show that OMA allows us to identify modes particularly present in the instrument's response with a good estimation especially if they are close to the excitation frequency with the modified LSCE method.

  19. Modal analysis of a loaded tire with non-contact measurements and piezoelectric excitation

    NASA Astrophysics Data System (ADS)

    Ferhat, Ipar; Tarazaga, Pablo A.

    2017-04-01

    The complex nature of tires requires very precise test data to model the structure accurately. The highly damped characteristics, geometric features and operational conditions of tires cause various testing difficulties that affect the reliability of the modal testing. One of the biggest challenges of tire testing is exciting the whole tire at once. Conventionally, impact hammers, shakers, and cleats are used as an excitation input. The shortcomings of these excitation methods are the directional and force inconsistency of hammer impacts, coupled dynamics of shakers and speed limitations of cleat excitation. Other challenges of modal testing of tires are the effect of added mass due to sensor placements and difficulty of vibration measurement of a rotating tire with accelerometers. In order to remedy these problems, we conduct experimental modal analysis (EMA) using a non-contact measurement technique and piezoelectric excitation. For non-contact measurement, a 3-D scanning laser doppler vibrometer (SLDV) is used. For the piezoelectric excitation, Micro Fiber Composite (MFC) patches are used due to their flexible nature and power capacity. This excitation method can also be crucial to the excitation of rotating tires since the cleat excitation is not adequate for low-speed measurements. Furthermore, the piezoelectric actuation could be used as sensors as well as noise controllers in operating conditions. For this work, we run experiments for a loaded tire in non-rotating condition. Experiments are carried out for the frequency bandwidth up to 500Hz to capture the structural behavior under high-frequency excitations and its potential coupled behavior to airborne noise.

  20. Contrast-based sensorless adaptive optics for retinal imaging.

    PubMed

    Zhou, Xiaolin; Bedggood, Phillip; Bui, Bang; Nguyen, Christine T O; He, Zheng; Metha, Andrew

    2015-09-01

    Conventional adaptive optics ophthalmoscopes use wavefront sensing methods to characterize ocular aberrations for real-time correction. However, there are important situations in which the wavefront sensing step is susceptible to difficulties that affect the accuracy of the correction. To circumvent these, wavefront sensorless adaptive optics (or non-wavefront sensing AO; NS-AO) imaging has recently been developed and has been applied to point-scanning based retinal imaging modalities. In this study we show, for the first time, contrast-based NS-AO ophthalmoscopy for full-frame in vivo imaging of human and animal eyes. We suggest a robust image quality metric that could be used for any imaging modality, and test its performance against other metrics using (physical) model eyes.

  1. Complementary and conventional providers in cancer care: experience of communication with patients and steps to improve communication with other providers.

    PubMed

    Stub, Trine; Quandt, Sara A; Arcury, Thomas A; Sandberg, Joanne C; Kristoffersen, Agnete E

    2017-06-08

    Effective interdisciplinary communication is important to achieve better quality in health care. The aims of this study were to compare conventional and complementary providers' experience of communication about complementary therapies and conventional medicine with their cancer patients, and to investigate how they experience interdisciplinary communication and cooperation. This study analyzed data from a self-administrated questionnaire. A total of 606 different health care providers, from four counties in Norway, completed the questionnaire. The survey was developed to describe aspects of the communication pattern among oncology doctors, nurses, family physicians and complementary therapists (acupuncturists, massage therapists and reflexologists/zone-therapists). Between-group differences were analyzed using chi-square, ANOVA and Fisher's exact tests. Significance level was defined as p < 0.05 without adjustment for multiple comparisons. Conventional providers and complementary therapists had different patterns of communication with their cancer patients regarding complementary therapies. While complementary therapists advised their patients to apply both complementary and conventional modalities, medical doctors were less supportive of their patients' use of complementary therapies. Of conventional providers, nurses expressed more positive attitudes toward complementary therapies. Opportunities to improve communication between conventional and complementary providers were most strongly supported by complementary providers and nurses; medical doctors were less supportive of such attempts. A number of doctors showed lack of respect for complementary therapists, but asked for more research, guidelines for complementary modalities and training in conventional medicine for complementary therapists. For better quality of care, greater communication about complementary therapy use is needed between cancer patients and their conventional and complementary providers. In addition, more communication between conventional and complementary providers is needed. Nurses may have a crucial role in facilitating communication, as they are positive toward complementary therapies and they have more direct communication with patients about their treatment preferences.

  2. Robotic therapy provides a stimulus for upper limb motor recovery after stroke that is complementary to and distinct from conventional therapy.

    PubMed

    Brokaw, Elizabeth B; Nichols, Diane; Holley, Rahsaan J; Lum, Peter S

    2014-05-01

    Individuals with chronic stroke often have long-lasting upper extremity impairments that impede function during activities of daily living. Rehabilitation robotics have shown promise in improving arm function, but current systems do not allow realistic training of activities of daily living. We have incorporated the ARMin III and HandSOME device into a novel robotic therapy modality that provides functional training of reach and grasp tasks. To compare the effects of equal doses of robotic and conventional therapy in individuals with chronic stroke. Subjects were randomized to 12 hours of robotic or conventional therapy and then crossed over to the other therapy type after a 1-month washout period. Twelve moderate to severely impaired individuals with chronic stroke were enrolled, and 10 completed the study. Across the 3-month study period, subjects showed significant improvements in the Fugl-Meyer (P = .013) and Box and Blocks tests (P = .028). The robotic intervention produced significantly greater improvements in the Action Research Arm Test than conventional therapy (P = .033). Gains in the Box and Blocks test from conventional therapy were larger than from robotic therapy in subjects who received conventional therapy after robotic therapy (P = .044). Data suggest that robotic therapy can elicit improvements in arm function that are distinct from conventional therapy and supplements conventional methods to improve outcomes. Results from this pilot study should be confirmed in a larger study.

  3. Identification of modal strains using sub-microstrain FBG data and a novel wavelength-shift detection algorithm

    NASA Astrophysics Data System (ADS)

    Anastasopoulos, Dimitrios; Moretti, Patrizia; Geernaert, Thomas; De Pauw, Ben; Nawrot, Urszula; De Roeck, Guido; Berghmans, Francis; Reynders, Edwin

    2017-03-01

    The presence of damage in a civil structure alters its stiffness and consequently its modal characteristics. The identification of these changes can provide engineers with useful information about the condition of a structure and constitutes the basic principle of the vibration-based structural health monitoring. While eigenfrequencies and mode shapes are the most commonly monitored modal characteristics, their sensitivity to structural damage may be low relative to their sensitivity to environmental influences. Modal strains or curvatures could offer an attractive alternative but current measurement techniques encounter difficulties in capturing the very small strain (sub-microstrain) levels occurring during ambient, or operational excitation, with sufficient accuracy. This paper investigates the ability to obtain sub-microstrain accuracy with standard fiber-optic Bragg gratings using a novel optical signal processing algorithm that identifies the wavelength shift with high accuracy and precision. The novel technique is validated in an extensive experimental modal analysis test on a steel I-beam which is instrumented with FBG sensors at its top and bottom flange. The raw wavelength FBG data are processed into strain values using both a novel correlation-based processing technique and a conventional peak tracking technique. Subsequently, the strain time series are used for identifying the beam's modal characteristics. Finally, the accuracy of both algorithms in identification of modal characteristics is extensively investigated.

  4. Process qualification and testing of LENS deposited AY1E0125 D-bottle brackets.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atwood, Clinton J.; Smugeresky, John E.; Jew, Michael

    2006-11-01

    The LENS Qualification team had the goal of performing a process qualification for the Laser Engineered Net Shaping{trademark}(LENS{reg_sign}) process. Process Qualification requires that a part be selected for process demonstration. The AY1E0125 D-Bottle Bracket from the W80-3 was selected for this work. The repeatability of the LENS process was baselined to determine process parameters. Six D-Bottle brackets were deposited using LENS, machined to final dimensions, and tested in comparison to conventionally processed brackets. The tests, taken from ES1E0003, included a mass analysis and structural dynamic testing including free-free and assembly-level modal tests, and Haversine shock tests. The LENS brackets performedmore » with very similar characteristics to the conventionally processed brackets. Based on the results of the testing, it was concluded that the performance of the brackets made them eligible for parallel path testing in subsystem level tests. The testing results and process rigor qualified the LENS process as detailed in EER200638525A.« less

  5. Specialized sperm function tests in varicocele and the future of andrology laboratory.

    PubMed

    Majzoub, Ahmad; Esteves, Sandro C; Gosálvez, Jaime; Agarwal, Ashok

    2016-01-01

    Varicocele is a common medical condition entangled with many controversies. Though it is highly prevalent in men with infertility, still it marks its presence in males who do have normal fertility. Determining which patients are negatively affected by varicocele would enable clinicians to better select those men who benefitted the most from surgery. Since conventional semen analysis has been limited in its ability to evaluate the negative effects of varicocele on fertility, a multitude of specialized laboratory tests have emerged. In this review, we examine the role and significance of specialized sperm function tests with regards to varicocele. Among the various tests, analysis of sperm DNA fragmentation and measurements of oxidative stress markers provide an independent measure of fertility in men with varicocele. These diagnostic modalities have both diagnostic and prognostic information complementary to, but distinct from conventional sperm parameters. Test results can guide management and aid in monitoring intervention outcomes. Proteomics, metabolomics, and genomics are areas; though still developing, holding promise to revolutionize our understanding of reproductive physiology, including varicocele.

  6. ROC Analysis of Chest Radiographs Using Computed Radiography and Conventional Analog Films

    NASA Astrophysics Data System (ADS)

    Morioka, Craig A.; Brown, Kathy; Hayrapetian, Alek S.; Kangarloo, Hooshang; Balter, Stephen; Huang, H. K.

    1989-05-01

    Receiver operating characteristic is used to compare the image quality of films obtained digitally using computed radiography (CR) and conventionally using analog film following fluoroscopic examination. Similar radiological views were obtained by both modalities. Twenty-four cases, some with a solitary noncalcified nodule and/or pneumothorax, were collected. Ten radiologists have been tested viewing analog and CR digital films separately. Final results indicate that there is no statistically significant difference in the ability to detect either a pneumothorax or a solitary noncalcified nodule when comparing CR digital film with conventional analog film. However, there is a trend that indicated the area under the ROC curves for detection of either a pneumothorax or solitary noncalcified nodule were greater for the analog film than for the digital film.

  7. Contrast-based sensorless adaptive optics for retinal imaging

    PubMed Central

    Zhou, Xiaolin; Bedggood, Phillip; Bui, Bang; Nguyen, Christine T.O.; He, Zheng; Metha, Andrew

    2015-01-01

    Conventional adaptive optics ophthalmoscopes use wavefront sensing methods to characterize ocular aberrations for real-time correction. However, there are important situations in which the wavefront sensing step is susceptible to difficulties that affect the accuracy of the correction. To circumvent these, wavefront sensorless adaptive optics (or non-wavefront sensing AO; NS-AO) imaging has recently been developed and has been applied to point-scanning based retinal imaging modalities. In this study we show, for the first time, contrast-based NS-AO ophthalmoscopy for full-frame in vivo imaging of human and animal eyes. We suggest a robust image quality metric that could be used for any imaging modality, and test its performance against other metrics using (physical) model eyes. PMID:26417525

  8. The sports performance application of vibration exercise for warm-up, flexibility and sprint speed.

    PubMed

    Cochrane, Darryl

    2013-01-01

    Since the turn of the 21st century, there has been a resurgence of vibration technology to enhance sport science especially for power and force development. However, vibration exercise has been trialled in other areas that are central to athlete performance such as warm-up, flexibility and sprint speed. Therefore, the aim of this review was to attempt to gain a better understanding of how acute and short-term vibration exercise may impact on warm-up, flexibility and sprint speed. The importance of warming up for sporting performance has been well documented and vibration exercise has the capability to be included or used as a standalone warm-up modality to increase intramuscular temperature at a faster rate compared to other conventional warm-up modalities. However, vibration exercise does not provide any additional neurogenic benefits compared to conventional dynamic and passive warm-up interventions. Vibration exercise appears to be a safe modality that does not produce any adverse affects causing injury or harm and could be used during interval and substitution breaks, as it would incur a low metabolic cost and be time-efficient compared to conventional warm-up modalities. Acute or short-term vibration exercise can enhance flexibility and range of motion without having a detrimental effect on muscle power, however it is less clear which mechanisms may be responsible for this enhancement. It appears that vibration exercise is not capable of improving sprint speed performance; this could be due to the complex and dynamic nature of sprinting where the purported increase in muscle power from vibration exercise is probably lost on repeated actions of high force generation. Vibration exercise is a safe modality that produces no adverse side effects for injury or harm. It has the time-efficient capability of providing coaches, trainers, and exercise specialists with an alternative modality that can be implemented for warm-up and flexibility either in isolation or in conjunction with other conventional training methods.

  9. Synthesizing spatiotemporally sparse smartphone sensor data for bridge modal identification

    NASA Astrophysics Data System (ADS)

    Ozer, Ekin; Feng, Maria Q.

    2016-08-01

    Smartphones as vibration measurement instruments form a large-scale, citizen-induced, and mobile wireless sensor network (WSN) for system identification and structural health monitoring (SHM) applications. Crowdsourcing-based SHM is possible with a decentralized system granting citizens with operational responsibility and control. Yet, citizen initiatives introduce device mobility, drastically changing SHM results due to uncertainties in the time and the space domains. This paper proposes a modal identification strategy that fuses spatiotemporally sparse SHM data collected by smartphone-based WSNs. Multichannel data sampled with the time and the space independence is used to compose the modal identification parameters such as frequencies and mode shapes. Structural response time history can be gathered by smartphone accelerometers and converted into Fourier spectra by the processor units. Timestamp, data length, energy to power conversion address temporal variation, whereas spatial uncertainties are reduced by geolocation services or determining node identity via QR code labels. Then, parameters collected from each distributed network component can be extended to global behavior to deduce modal parameters without the need of a centralized and synchronous data acquisition system. The proposed method is tested on a pedestrian bridge and compared with a conventional reference monitoring system. The results show that the spatiotemporally sparse mobile WSN data can be used to infer modal parameters despite non-overlapping sensor operation schedule.

  10. Quantitative Imaging Biomarkers of NAFLD

    PubMed Central

    Kinner, Sonja; Reeder, Scott B.

    2016-01-01

    Conventional imaging modalities, including ultrasonography (US), computed tomography (CT), and magnetic resonance (MR), play an important role in the diagnosis and management of patients with nonalcoholic fatty liver disease (NAFLD) by allowing noninvasive diagnosis of hepatic steatosis. However, conventional imaging modalities are limited as biomarkers of NAFLD for various reasons. Multi-parametric quantitative MRI techniques overcome many of the shortcomings of conventional imaging and allow comprehensive and objective evaluation of NAFLD. MRI can provide unconfounded biomarkers of hepatic fat, iron, and fibrosis in a single examination—a virtual biopsy has become a clinical reality. In this article, we will review the utility and limitation of conventional US, CT, and MR imaging for the diagnosis NAFLD. Recent advances in imaging biomarkers of NAFLD are also discussed with an emphasis in multi-parametric quantitative MRI. PMID:26848588

  11. Using experimental modal analysis to assess the behaviour of timber elements

    NASA Astrophysics Data System (ADS)

    Kouroussis, Georges; Fekih, Lassaad Ben; Descamps, Thierry

    2018-03-01

    Timber frameworks are one of the most important and widespread types of structures. Their configurations and joints are usually complex and require a high level of craftsmanship to assemble. In the field of restoration, a good understanding of the structural behaviour is necessary and is often based on assessment techniques dedicated to wood characterisation. This paper presents the use of experimental modal analysis for finite element updating. To do this, several timber beams in a free supported condition were analysed in order to extract their bending natural characteristics (frequency, damping and mode shapes). Corresponding ABAQUS finite element models were derived which included the effects of local defects (holes, cracks and wood nodes), moisture and structural decay. To achieve the modal updating, additional simulations were performed in order to study the sensitivity of the mechanical parameters. With the intent to estimate their mechanical properties, a procedure of modal updating was carried out in MatLab with a Python script. This was created to extract the modal information from the ABAQUS modal analysis results to be compared with the experimental results. The updating was based on a minimum of unconstrained multivariable function using a derivative-free method. The objective function was selected from the conventional comparison tools (absolute or relative frequency difference, and/or modal assurance criterion). This testing technique was used to determine the dynamic mechanical properties of timber beams, such as the anisotropic Young's Moduli and damping ratio. To verify the modulus, a series of static 4-point bending tests and STS04 classifications were conducted. The results also revealed that local defects have a negligible influence on natural frequencies. The results demonstrate that this assessment tool offers an effective method to obtain the mechanical properties of timber elements, especially when on-site and non-destructive techniques are needed, for example when retrofitting an existing structure.

  12. Applications of Advanced, Waveform Based AE Techniques for Testing Composite Materials

    NASA Technical Reports Server (NTRS)

    Prosser, William H.

    1996-01-01

    Advanced, waveform based acoustic emission (AE) techniques have been previously used to evaluate damage progression in laboratory tests of composite coupons. In these tests, broad band, high fidelity acoustic sensors were used to detect signals which were then digitized and stored for analysis. Analysis techniques were based on plate mode wave propagation characteristics. This approach, more recently referred to as Modal AE, provides an enhanced capability to discriminate and eliminate noise signals from those generated by damage mechanisms. This technique also allows much more precise source location than conventional, threshold crossing arrival time determination techniques. To apply Modal AE concepts to the interpretation of AE on larger composite structures, the effects of wave propagation over larger distances and through structural complexities must be well characterized and understood. In this research, measurements were made of the attenuation of the extensional and flexural plate mode components of broad band simulated AE signals in large composite panels. As these materials have applications in a cryogenic environment, the effects of cryogenic insulation on the attenuation of plate mode AE signals were also documented.

  13. A Dynamic Calibration Method for Experimental and Analytical Hub Load Comparison

    NASA Technical Reports Server (NTRS)

    Kreshock, Andrew R.; Thornburgh, Robert P.; Wilbur, Matthew L.

    2017-01-01

    This paper presents the results from an ongoing effort to produce improved correlation between analytical hub force and moment prediction and those measured during wind-tunnel testing on the Aeroelastic Rotor Experimental System (ARES), a conventional rotor testbed commonly used at the Langley Transonic Dynamics Tunnel (TDT). A frequency-dependent transformation between loads at the rotor hub and outputs of the testbed balance is produced from frequency response functions measured during vibration testing of the system. The resulting transformation is used as a dynamic calibration of the balance to transform hub loads predicted by comprehensive analysis into predicted balance outputs. In addition to detailing the transformation process, this paper also presents a set of wind-tunnel test cases, with comparisons between the measured balance outputs and transformed predictions from the comprehensive analysis code CAMRAD II. The modal response of the testbed is discussed and compared to a detailed finite-element model. Results reveal that the modal response of the testbed exhibits a number of characteristics that make accurate dynamic balance predictions challenging, even with the use of the balance transformation.

  14. Reward maximization justifies the transition from sensory selection at childhood to sensory integration at adulthood.

    PubMed

    Daee, Pedram; Mirian, Maryam S; Ahmadabadi, Majid Nili

    2014-01-01

    In a multisensory task, human adults integrate information from different sensory modalities--behaviorally in an optimal Bayesian fashion--while children mostly rely on a single sensor modality for decision making. The reason behind this change of behavior over age and the process behind learning the required statistics for optimal integration are still unclear and have not been justified by the conventional Bayesian modeling. We propose an interactive multisensory learning framework without making any prior assumptions about the sensory models. In this framework, learning in every modality and in their joint space is done in parallel using a single-step reinforcement learning method. A simple statistical test on confidence intervals on the mean of reward distributions is used to select the most informative source of information among the individual modalities and the joint space. Analyses of the method and the simulation results on a multimodal localization task show that the learning system autonomously starts with sensory selection and gradually switches to sensory integration. This is because, relying more on modalities--i.e. selection--at early learning steps (childhood) is more rewarding than favoring decisions learned in the joint space since, smaller state-space in modalities results in faster learning in every individual modality. In contrast, after gaining sufficient experiences (adulthood), the quality of learning in the joint space matures while learning in modalities suffers from insufficient accuracy due to perceptual aliasing. It results in tighter confidence interval for the joint space and consequently causes a smooth shift from selection to integration. It suggests that sensory selection and integration are emergent behavior and both are outputs of a single reward maximization process; i.e. the transition is not a preprogrammed phenomenon.

  15. A new procedure of modal parameter estimation for high-speed digital image correlation

    NASA Astrophysics Data System (ADS)

    Huňady, Róbert; Hagara, Martin

    2017-09-01

    The paper deals with the use of 3D digital image correlation in determining modal parameters of mechanical systems. It is a non-contact optical method, which for the measurement of full-field spatial displacements and strains of bodies uses precise digital cameras with high image resolution. Most often this method is utilized for testing of components or determination of material properties of various specimens. In the case of using high-speed cameras for measurement, the correlation system is capable of capturing various dynamic behaviors, including vibration. This enables the potential use of the mentioned method in experimental modal analysis. For that purpose, the authors proposed a measuring chain for the correlation system Q-450 and developed a software application called DICMAN 3D, which allows the direct use of this system in the area of modal testing. The created application provides the post-processing of measured data and the estimation of modal parameters. It has its own graphical user interface, in which several algorithms for the determination of natural frequencies, mode shapes and damping of particular modes of vibration are implemented. The paper describes the basic principle of the new estimation procedure which is crucial in the light of post-processing. Since the FRF matrix resulting from the measurement is usually relatively large, the estimation of modal parameters directly from the FRF matrix may be time-consuming and may occupy a large part of computer memory. The procedure implemented in DICMAN 3D provides a significant reduction in memory requirements and computational time while achieving a high accuracy of modal parameters. Its computational efficiency is particularly evident when the FRF matrix consists of thousands of measurement DOFs. The functionality of the created software application is presented on a practical example in which the modal parameters of a composite plate excited by an impact hammer were determined. For the verification of the obtained results a verification experiment was conducted during which the vibration responses were measured using conventional acceleration sensors. In both cases MIMO analysis was realized.

  16. Specialized sperm function tests in varicocele and the future of andrology laboratory

    PubMed Central

    Majzoub, Ahmad; Esteves, Sandro C; Gosálvez, Jaime; Agarwal, Ashok

    2016-01-01

    Varicocele is a common medical condition entangled with many controversies. Though it is highly prevalent in men with infertility, still it marks its presence in males who do have normal fertility. Determining which patients are negatively affected by varicocele would enable clinicians to better select those men who benefitted the most from surgery. Since conventional semen analysis has been limited in its ability to evaluate the negative effects of varicocele on fertility, a multitude of specialized laboratory tests have emerged. In this review, we examine the role and significance of specialized sperm function tests with regards to varicocele. Among the various tests, analysis of sperm DNA fragmentation and measurements of oxidative stress markers provide an independent measure of fertility in men with varicocele. These diagnostic modalities have both diagnostic and prognostic information complementary to, but distinct from conventional sperm parameters. Test results can guide management and aid in monitoring intervention outcomes. Proteomics, metabolomics, and genomics are areas; though still developing, holding promise to revolutionize our understanding of reproductive physiology, including varicocele. PMID:26780873

  17. Utilizing Multi-Modal Literacies in Middle Grades Science

    ERIC Educational Resources Information Center

    Saurino, Dan; Ogletree, Tamra; Saurino, Penelope

    2010-01-01

    The nature of literacy is changing. Increased student use of computer-mediated, digital, and visual communication spans our understanding of adolescent multi-modal capabilities that reach beyond the traditional conventions of linear speech and written text in the science curriculum. Advancing technology opens doors to learning that involve…

  18. The use of LigaSure in patients with hyperthyroidism.

    PubMed

    Barbaros, Umut; Erbil, Yeşim; Bozbora, Alp; Deveci, Uğur; Aksakal, Nihat; Dinççağ, Ahmet; Ozarmağan, Selçuk

    2006-11-01

    Thyroidectomies of hyperthyroidic patients are known to be more blood-spattered than the operations performed for euthyroid nodular diseases and require careful hemostasis. Our purpose was to evaluate the efficacy of the use of LigaSure in patients with hyperthyroidism. Between January 2004 and October 2005, 100 patients underwent total or near-total thyroidectomy. Bipolar vessel ligation system (LigaSure) was the choice of modality for hemostasis in half of these patients, and the conventional suture ligation technique was used for the rest. The following data were evaluated non-randomized and prospectively in this study: patients demographics, thyroid pathology, operative duration, presence of complications, and the duration of the hospital stay. Comparisons of the data were evaluated by the Wilcoxon and chi-square tests. Among the patients of the LigaSure group, 14 patients were detected to have hyperthyroidism (seven patients with Graves' disease and another seven patients with multinodular toxic goiter), while 36 patients were found to be euthyroidic. The durations of the operation time and of the hospital stay of the patients in the LigaSure group were significantly lower than the conventional thyroidectomy group (p<0.05). The complication rates of the LigaSure and conventional thyroidectomy groups were 4 and 6%, respectively (p>0.05). The use of LigaSure as an operative technique in the treatment of Graves' disease and toxic goiter is a safe and effective modality that provides a shorter hospital stay and a shorter operation time as well.

  19. A Locally Modal B-Spline Based Full-Vector Finite-Element Method with PML for Nonlinear and Lossy Plasmonic Waveguide

    NASA Astrophysics Data System (ADS)

    Karimi, Hossein; Nikmehr, Saeid; Khodapanah, Ehsan

    2016-09-01

    In this paper, we develop a B-spline finite-element method (FEM) based on a locally modal wave propagation with anisotropic perfectly matched layers (PMLs), for the first time, to simulate nonlinear and lossy plasmonic waveguides. Conventional approaches like beam propagation method, inherently omit the wave spectrum and do not provide physical insight into nonlinear modes especially in the plasmonic applications, where nonlinear modes are constructed by linear modes with very close propagation constant quantities. Our locally modal B-spline finite element method (LMBS-FEM) does not suffer from the weakness of the conventional approaches. To validate our method, first, propagation of wave for various kinds of linear, nonlinear, lossless and lossy materials of metal-insulator plasmonic structures are simulated using LMBS-FEM in MATLAB and the comparisons are made with FEM-BPM module of COMSOL Multiphysics simulator and B-spline finite-element finite-difference wide angle beam propagation method (BSFEFD-WABPM). The comparisons show that not only our developed numerical approach is computationally more accurate and efficient than conventional approaches but also it provides physical insight into the nonlinear nature of the propagation modes.

  20. Dynamic Analysis of Heavy Vehicle Medium Duty Drive Shaft Using Conventional and Composite Material

    NASA Astrophysics Data System (ADS)

    Kumar, Ashwani; Jain, Rajat; Patil, Pravin P.

    2016-09-01

    The main highlight of this study is structural and modal analysis of single piece drive shaft for selection of material. Drive shaft is used for torque carrying from vehicle transmission to rear wheel differential system. Heavy vehicle medium duty transmission drive shaft was selected as research object. Conventional materials (Steel SM45 C, Stainless Steel) and composite materials (HS carbon epoxy, E Glass Polyester Resin Composite) were selected for the analysis. Single piece composite material drive shaft has advantage over conventional two-piece steel drive shaft. It has higher specific strength, longer life, less weight, high critical speed and higher torque carrying capacity. The main criteria for drive shaft failure are strength and weight. Maximum modal frequency obtained is 919 Hz. Various harmful vibration modes (lateral vibration and torsional vibration) were identified and maximum deflection region was specified. For single-piece drive shaft the natural bending frequency should be higher because it is subjected to torsion and shear stress. Single piece drive shaft was modelled using Solid Edge and Pro-E. Finite Element Analysis was used for structural and modal analysis with actual running boundary condition like frictional support, torque and moment. FEA simulation results were validated with experimental literature results.

  1. Surveying New Testament Survey: The Impact of Demographics and Modality on an Introductory New Testament Class

    ERIC Educational Resources Information Center

    Bruehler, Bart B.

    2014-01-01

    Both adult and traditional students at Indiana Wesleyan University take an introductory New Testament course in conventional, compressed, and accelerated formats and through online and onsite settings. This wide variety of demographics and modalities raises the issues of if and how the various incarnations of this course facilitate the achievement…

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veedu, Vinod; Hadmack, Michael; Pollock, Jacob

    Nanite™ is a cementitious material that contains a proprietary formulation of functionalized nanomaterial additive to transform conventional cement into a smart material responsive to pressure (or stress), temperature, and any intrinsic changes in composition. This project has identified optimal sensing modalities of smart well cement and demonstrated how real-time sensing of Nanite™ can improve long-term wellbore integrity and zonal isolation in shale gas and applicable oil and gas operations. Oceanit has explored Nanite’s electrical sensing properties in depth and has advanced the technology from laboratory proof-of-concept to sub-scale testing in preparation for field trials.

  3. Correlation Results for a Mass Loaded Vehicle Panel Test Article Finite Element Models and Modal Survey Tests

    NASA Technical Reports Server (NTRS)

    Maasha, Rumaasha; Towner, Robert L.

    2012-01-01

    High-fidelity Finite Element Models (FEMs) were developed to support a recent test program at Marshall Space Flight Center (MSFC). The FEMs correspond to test articles used for a series of acoustic tests. Modal survey tests were used to validate the FEMs for five acoustic tests (a bare panel and four different mass-loaded panel configurations). An additional modal survey test was performed on the empty test fixture (orthogrid panel mounting fixture, between the reverb and anechoic chambers). Modal survey tests were used to test-validate the dynamic characteristics of FEMs used for acoustic test excitation. Modal survey testing and subsequent model correlation has validated the natural frequencies and mode shapes of the FEMs. The modal survey test results provide a basis for the analysis models used for acoustic loading response test and analysis comparisons

  4. Expanding role of 18F-fluoro-d-deoxyglucose PET and PET/CT in spinal infections

    PubMed Central

    Rijk, Paul C.; Collins, James M. P.; Parlevliet, Thierry; Stumpe, Katrin D.; Palestro, Christopher J.

    2010-01-01

    18F-fluoro-d-deoxyglucose positron emission tomography ([18F]-FDG PET) is successfully employed as a molecular imaging technique in oncology, and has become a promising imaging modality in the field of infection. The non-invasive diagnosis of spinal infections (SI) has been a challenge for physicians for many years. Morphological imaging modalities such as conventional radiography, computed tomography (CT), and magnetic resonance imaging (MRI) are techniques frequently used in patients with SI. However, these methods are sometimes non-specific, and difficulties in differentiating infectious from degenerative end-plate abnormalities or postoperative changes can occur. Moreover, in contrast to CT and MRI, FDG uptake in PET is not hampered by metallic implant-associated artifacts. Conventional radionuclide imaging tests, such as bone scintigraphy, labeled leukocyte, and gallium scanning, suffer from relatively poor spatial resolution and lack sensitivity, specificity, or both. Initial data show that [18F]-FDG PET is an emerging imaging technique for diagnosing SI. [18F]-FDG PET appears to be especially helpful in those cases in which MRI cannot be performed or is non-diagnostic, and as an adjunct in patients in whom the diagnosis is inconclusive. The article reviews the currently available literature on [18F]-FDG PET and PET/CT in the diagnosis of SI. PMID:20052505

  5. Comparison of sine dwell and broadband methods for modal testing

    NASA Technical Reports Server (NTRS)

    Chen, Jay-Chung

    1989-01-01

    The objectives of modal tests for large complex spacecraft structural systems are outlined. The comparison criteria for the modal test methods, namely, the broadband excitation and the sine dwell methods, are established. Using the Galileo spacecraft modal test and the Centaur G Prime upper stage vehicle modal test as examples, the relative advantage or disadvantage of each method is examined. The usefulness or shortcomings of the methods are given from a practical engineering viewpoint.

  6. The Inception of OMA in the Development of Modal Testing Technology for Wind Turbines

    NASA Technical Reports Server (NTRS)

    James, George H., III; Carne. Thomas G.

    2008-01-01

    Wind turbines are immense, flexible structures with aerodynamic forces acting on the rotating blades at harmonics of the turbine rotational frequency, which are comparable to the modal frequencies of the structure. Predicting and experimentally measuring the modal frequencies of wind turbines has been important to their successful design and operation. Performing modal tests on wind turbine structures over 100 meters tall is a substantial challenge, which has inspired innovative developments in modal test technology. For wind turbines, a further complication is that the modal frequencies are dependent on the turbine rotation speed. The history and development of a new technique for acquiring the modal parameters using output-only response data, called the Natural Excitation Technique (NExT), will be reviewed, showing historical tests and techniques. The initial attempts at output-only modal testing began in the late 1980's with the development of NExT in the 1990's. NExT was a predecessor to OMA, developed to overcome these challenges of testing immense structures excited with environmental inputs. We will trace the difficulties and successes of wind turbine modal testing from 1982 to the present. Keywords: OMA, Modal Analysis, NExT, Wind Turbines, Wind Excitation

  7. On sine dwell or broadband methods for modal testing

    NASA Technical Reports Server (NTRS)

    Chen, Jay-Chung; Wada, Ben K.

    1987-01-01

    For large, complex spacecraft structural systems, the objectives of the modal test are outlined. Based on these objectives, the comparison criteria for the modal test methods, namely, the broadband excitation and the sine dwell methods are established. Using the Galileo spacecraft modal test and the Centaur G Prime upper stage vehicle modal test as examples, the relative advantages or disadvantages of each method are examined. The usefulness or shortcoming of the methods are given from a practicing engineer's view point.

  8. Modal analysis using a Fourier analyzer, curve-fitting, and modal tuning

    NASA Technical Reports Server (NTRS)

    Craig, R. R., Jr.; Chung, Y. T.

    1981-01-01

    The proposed modal test program differs from single-input methods in that preliminary data may be acquired using multiple inputs, and modal tuning procedures may be employed to define closely spaced frquency modes more accurately or to make use of frequency response functions (FRF's) which are based on several input locations. In some respects the proposed modal test proram resembles earlier sine-sweep and sine-dwell testing in that broadband FRF's are acquired using several input locations, and tuning is employed to refine the modal parameter estimates. The major tasks performed in the proposed modal test program are outlined. Data acquisition and FFT processing, curve fitting, and modal tuning phases are described and examples are given to illustrate and evaluate them.

  9. Tearing down the barriers to daily home hemodialysis and achieving the highest value renal therapy through holistic product design.

    PubMed

    Kenley, R S

    1996-04-01

    Renal therapy value can be defined as the ratio of outcomes achieved by a dialytic therapy to the total cost of providing that therapy. One desirable goal of any dialysis modality would be the achievement of maximum value. Unfortunately, with conventional hemodialysis and peritoneal dialysis modalities, improving outcomes has always been linked to a simultaneous increase in costs, thereby leaving value relatively unchanged. However, a new modality, daily home hemodialysis, finally may allow this linkage to be broken. The outcomes are dramatically improved as a result of a higher quantity and quality of dialysis dose resulting from the greater frequency of treatments. The costs can be reduced by minimizing the consumed items, avoiding the labor and overhead of dialysis clinics, and reducing the costs associated with morbidity. Provision of this therapy is, however, predicated on the availability of instrumentation designed specifically for it because conventional equipment designed for in-center use is not suitable. By starting with a clean sheet of paper and incorporating such features as insitu reuse of the entire extracorporeal circuit, remote telemonitoring, automated system disinfection, and integrated water purification, most of the impediments to performing this modality can be overcome.

  10. Differences in Multi-Modal Ultrasound Imaging between Triple Negative and Non-Triple Negative Breast Cancer.

    PubMed

    Li, Ziyao; Tian, Jiawei; Wang, Xiaowei; Wang, Ying; Wang, Zhenzhen; Zhang, Lei; Jing, Hui; Wu, Tong

    2016-04-01

    The objective of this study was to identify multi-modal ultrasound imaging parameters that could potentially help to differentiate between triple negative breast cancer (TNBC) and non-TNBC. Conventional ultrasonography, ultrasound strain elastography and 3-D ultrasound (3-D-US) findings from 50 TNBC and 179 non-TNBC patients were retrospectively reviewed. Immunohistochemical examination was used as the reference gold standard for cancer subtyping. Different ultrasound modalities were initially analyzed to define TNBC-related features. Subsequently, logistic regression analysis was applied to TNBC-related features to establish models for predicting TNBC. TNBCs often presented as micro-lobulated, markedly hypo-echoic masses with an abrupt interface (p = 0.015, 0.0015 and 0.004, compared with non-TNBCs, respectively) on conventional ultrasound, and showed a diminished retraction pattern phenomenon in the coronal plane (p = 0.035) on 3-D-US. Our findings suggest that B-mode ultrasound and 3-D-US in multi-modality ultrasonography could be a useful non-invasive technique for differentiating TNBCs from non-TNBCs. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. Performing a Large-Scale Modal Test on the B2 Stand Crane at NASA's Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Stasiunas, Eric C.; Parks, Russel A.

    2018-01-01

    A modal test of NASA’s Space Launch System (SLS) Core Stage is scheduled to occur prior to propulsion system verification testing at the Stennis Space Center B2 test stand. A derrick crane with a 180-ft long boom, located at the top of the stand, will be used to suspend the Core Stage in order to achieve defined boundary conditions. During this suspended modal test, it is expected that dynamic coupling will occur between the crane and the Core Stage. Therefore, a separate modal test was performed on the B2 crane itself, in order to evaluate the varying dynamic characteristics and correlate math models of the crane. Performing a modal test on such a massive structure was challenging and required creative test setup and procedures, including implementing both AC and DC accelerometers, and performing both classical hammer and operational modal analysis. This paper describes the logistics required to perform this large-scale test, as well as details of the test setup, the modal test methods used, and an overview of the results.

  12. Sensitivity and specificity of linear array intraoperative ultrasound in glioblastoma surgery: a comparative study with high field intraoperative MRI and conventional sector array ultrasound.

    PubMed

    Coburger, Jan; Scheuerle, Angelika; Kapapa, Thomas; Engelke, Jens; Thal, Dietmar Rudolf; Wirtz, Christian R; König, Ralph

    2015-07-01

    Linear array intraoperative ultrasound (lioUS) is an emerging technology for intracranial use. We evaluated sensitivity and specificity of lioUS to detect residual tumor in patients harboring a glioblastoma. After near total resection in 20 patients, residual tumor detection using lioUS, conventional intraoperative ultrasound (cioUS), and gadopentetic-diethylenetriamine penta-acetic acid (Gd-DTPA)-enhanced intraoperative MRI (iMRI) were compared. Sensitivity and specificity were calculated based on 68 navigated biopsies. Receiver operator characteristic (ROC) curves and correlation with histopathological findings of each imaging modality were calculated. Additionally, results were evaluated in the subgroup of recurrent disease (23 biopsies in 8 patients). Sensitivity of lioUS (76 %) was significantly higher compared with iMRI (55 %) and cioUS (24 %). Specificity of lioUS (58 %) was significantly lower than in cioUS (96 %), while there was no significant difference to iMRI (74 %). All imaging modalities correlated significantly with histopathological findings. In the subgroup of recurrent disease, sensitivity and specificity decreased in all modalities. However, cioUS showed significant lower values than iMRI and lioUS. In ROC curves, lioUS showed a higher area und the curve (AUC) in comparison with iMRI and cioUS. We found similar results in the subgroup of recurrent disease. Tumor detection using a lioUS is significantly superior to cioUS. Overall test performance in lioUS is comparable with results of iMRI. While, the latter has a higher specificity and a significantly lower sensitivity in comparison with lioUS.

  13. Neurophysiological testing in anorectal disorders

    PubMed Central

    Remes-Troche, Jose M; Rao, Satish SC

    2013-01-01

    Neurophysiological tests of anorectal function can provide useful information regarding the integrity of neuronal innervation, as well as neuromuscular function. This information can give insights regarding the pathophysiological mechanisms that lead to several disorders of anorectal function, particularly fecal incontinence, pelvic floor disorders and dyssynergic defecation. Currently, several tests are available for the neurophysiological evaluation of anorectal function. These tests are mostly performed on patients referred to tertiary care centers, either following negative evaluations or when there is lack of response to conventional therapy. Judicious use of these tests can reveal significant and new understanding of the underlying mechanism(s) that could pave the way for better management of these disorders. In addition, these techniques are complementary to other modalities of investigation, such as pelvic floor imaging. The most commonly performed neurophysiological tests, along with their indications and clinical utility are discussed. Several novel techniques are evolving that may reveal new information on brain–gut interactions. PMID:19072383

  14. Comparison of multi-modal early oral nutrition for the tolerance of oral nutrition with conventional care after major abdominal surgery: a prospective, randomized, single-blind trial.

    PubMed

    Sun, Da-Li; Li, Wei-Ming; Li, Shu-Min; Cen, Yun-Yun; Xu, Qing-Wen; Li, Yi-Jun; Sun, Yan-Bo; Qi, Yu-Xing; Lin, Yue-Ying; Yang, Ting; Lu, Qi-Ping; Xu, Peng-Yuan

    2017-02-10

    Early oral nutrition (EON) has been shown to improve recovery of gastrointestinal function, length of stay and mortality after abdominal surgery; however, early oral nutrition often fails during the first week after surgery. Here, a multi-modal early oral nutrition program is introduced to promote recovery of gastrointestinal function and tolerance of oral nutrition. Consecutive patients scheduled for abdominal surgery were randomized to the multimodal EON group or a group receiving conventional care. The primary endpoint was the time of first defecation. The secondary endpoints were outcomes and the cost-effectiveness ratio in treating infectious complications. The rate of infectious-free patients was regarded as the index of effectiveness. One hundred seven patients were randomly assigned to groups. Baseline characteristics were similar for both groups. In intention-to-treat analysis, the success rate of oral nutrition during the first week after surgery in the multimodal EON group was 44 (83.0%) versus 31 (57.4%) in the conventional care group (P = 0.004). Time to first defecation, time to flatus, recovery time of bowel sounds, and prolonged postoperative ileus were all less in the multimodal EON group (P < 0.05). The median postoperative length of stay in the multimodal EON group was 8 days (6, 12) versus 10 days (7, 18) in the conventional care group (P < 0.001). The total cost of treatment and nutritional support were also less in the multi-modal early oral nutrition group (P < 0.001). The effectiveness was 84.9 and 79.9% in the multimodal EON and conventional care group, respectively (P = 0.475). However, the cost-effectiveness ratio was USD 537.6 (506.1, 589.3) and USD 637.8 (593.9, 710.3), respectively (P < 0.001). The multi-modal early oral nutrition program was an effective way to improve tolerance of oral nutrition during the first week after surgery, decrease the length of stay and improve cost-effectiveness after abdominal surgery. Registration number: ChiCTR-TRC-14004395 . Registered 15 March 2014.

  15. Performing a Large-Scale Modal Test on the B2 Stand Crane at NASA's Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Stasiunas, Eric C.; Parks, Russel A.; Sontag, Brendan D.

    2018-01-01

    A modal test of NASA's Space Launch System (SLS) Core Stage is scheduled to occur at the Stennis Space Center B2 test stand. A derrick crane with a 150-ft long boom, located at the top of the stand, will be used to suspend the Core Stage in order to achieve defined boundary conditions. During this suspended modal test, it is expected that dynamic coupling will occur between the crane and the Core Stage. Therefore, a separate modal test was performed on the B2 crane itself, in order to evaluate the varying dynamic characteristics and correlate math models of the crane. Performing a modal test on such a massive structure was challenging and required creative test setup and procedures, including implementing both AC and DC accelerometers, and performing both classical hammer and operational modal analysis. This paper describes the logistics required to perform this large-scale test, as well as details of the test setup, the modal test methods used, and an overview and application of the results.

  16. A highly sensitive x-ray imaging modality for hepatocellular carcinoma detection in vitro

    NASA Astrophysics Data System (ADS)

    Rand, Danielle; Walsh, Edward G.; Derdak, Zoltan; Wands, Jack R.; Rose-Petruck, Christoph

    2015-01-01

    Innovations that improve sensitivity and reduce cost are of paramount importance in diagnostic imaging. The novel x-ray imaging modality called spatial frequency heterodyne imaging (SFHI) is based on a linear arrangement of x-ray source, tissue, and x-ray detector, much like that of a conventional x-ray imaging apparatus. However, SFHI rests on a complete paradigm reversal compared to conventional x-ray absorption-based radiology: while scattered x-rays are carefully rejected in absorption-based x-ray radiology to enhance the image contrast, SFHI forms images exclusively from x-rays scattered by the tissue. In this study we use numerical processing to produce x-ray scatter images of hepatocellular carcinoma labeled with a nanoparticle contrast agent. We subsequently compare the sensitivity of SFHI in this application to that of both conventional x-ray imaging and magnetic resonance imaging (MRI). Although SFHI is still in the early stages of its development, our results show that the sensitivity of SFHI is an order of magnitude greater than that of absorption-based x-ray imaging and approximately equal to that of MRI. As x-ray imaging modalities typically have lower installation and service costs compared to MRI, SFHI could become a cost effective alternative to MRI, particularly in areas of the world with inadequate availability of MRI facilities.

  17. Alternative synthetic aperture radar (SAR) modalities using a 1D dynamic metasurface antenna

    NASA Astrophysics Data System (ADS)

    Boyarsky, Michael; Sleasman, Timothy; Pulido-Mancera, Laura; Imani, Mohammadreza F.; Reynolds, Matthew S.; Smith, David R.

    2017-05-01

    Synthetic aperture radar (SAR) systems conventionally rely on mechanically-actuated reflector dishes or large phased arrays for generating steerable directive beams. While these systems have yielded high-resolution images, the hardware suffers from considerable weight, high cost, substantial power consumption, and moving parts. Since these disadvantages are particularly relevant in airborne and spaceborne systems, a flat, lightweight, and low-cost solution is a sought-after goal. Dynamic metasurface antennas have emerged as a recent technology for generating waveforms with desired characteristics. Metasurface antennas consist of an electrically-large waveguide loaded with numerous subwavelength radiators which selectively leak energy from a guided wave into free space to form various radiation patterns. By tuning each radiating element, we can modulate the aperture's overall radiation pattern to generate steered directive beams, without moving parts or phase shifters. Furthermore, by using established manufacturing methods, these apertures can be made to be lightweight, low-cost, and planar, while maintaining high performance. In addition to their hardware benefits, dynamic metasurfaces can leverage their dexterity and high switching speeds to enable alternative SAR modalities for improved performance. In this work, we briefly discuss how dynamic metasurfaces can conduct existing SAR modalities with similar performance as conventional systems from a significantly simpler hardware platform. We will also describe two additional modalities which may achieve improved performance as compared to traditional modalities. These modalities, enhanced resolution stripmap and diverse pattern stripmap, offer the ability to circumvent the trade-off between resolution and region-of-interest size that exists within stripmap and spotlight. Imaging results with a simulated dynamic metasurface verify the benefits of these modalities and a discussion of implementation considerations and noise effects is also included. Ultimately, the hardware gains coupled with the additional modalities well-suited to dynamic metasurface antennas has poised them to propel the SAR field forward and open the door to exciting opportunities.

  18. 40 CFR 1033.520 - Alternative ramped modal cycles.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Following the completion of the third test phase of the applicable ramped modal cycle, conduct the post... POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Test Procedures § 1033.520 Alternative ramped modal... locomotive notch settings. Ramped modal cycles combine multiple test modes of a discrete-mode steady-state...

  19. Track/train dynamics test report modal survey

    NASA Technical Reports Server (NTRS)

    Vigil, R. A.

    1975-01-01

    The modal survey vibration test conducted on an 80 ton open hopper freight car is described. The test data, the post-test update of the modal survey test requirements and procedure, and an index to the test data are presented. Photographs of actual measurement locations and the test historical log are included.

  20. The Development of Modal Testing Technology for Wind Turbines: A Historical Perspective

    NASA Technical Reports Server (NTRS)

    James, George H., III; Carne, Thomas G.

    2007-01-01

    Wind turbines are very large, flexible structures, with aerodynamic forces on the rotating blades producing periodic forces with frequencies at the harmonics of the rotation frequency. Due to design consideration, these rotational frequencies are comparable to the modal frequencies; thus avoiding resonant conditions is a critical consideration. Consequently, predicting and experimentally validating the modal frequencies of wind turbines has been important to their successful design and operation. Performing modal tests on flexible structures over 120 meters tall is a substantial challenge, which has inspired innovative developments in modal test technology. A further trial to the analyst and experimentalist is that the modal frequencies are dependent on the turbine rotation speed, so testing a parked turbine does not fully validate the analytical predictions. The history and development of this modal testing technology will be reviewed, showing historical tests and techniques, ranging from two-meter to 100-meter turbines for both parked and rotating tests. The NExT (Natural Excitation Technique) was developed in the 1990's, as a predecessor to OMA to overcome these challenges. We will trace the difficulties and successes of wind turbine modal testing over the past twenty-five years from 1982 to the present.

  1. Comparison of Diagnostic Yield of a FISH Panel Against Conventional Cytogenetic Studies for Hematological Malignancies: A South Indian Referral Laboratory Analysis Of 201 Cases

    PubMed Central

    Ashok, Vishal; Ranganathan, Ramya; Chander, Smitha; Damodar, Sharat; Bhat, Sunil; KS, Nataraj; A, Satish Kumar; Jadav, Sachin Suresh; Rajashekaraiah, Mahesh; TS, Sundareshan

    2017-01-01

    Objectives: Genetic markers are crucial fort diagnostic and prognostic investigation of hematological malignancies (HM). The conventional cytogenetic study (CCS) has been the gold standard for more than five decades. However, FISH (Fluorescence in Situ Hybridization) testing has become a popular modality owing to its targeted approach and the ability to detect abnormalities in non-mitotic cells. We here aimed to compare the diagnostic yields of a FISH panel against CCS in HMs. Methods: Samples of bone marrow and peripheral blood for a total of 201 HMs were tested for specific gene rearrangements using multi-target FISH and the results were compared with those from CCS. Results: Exhibited a greater diagnostic yield with a positive result in 39.8% of the cases, as compared to 17.9% of cases detected by CCS. Cases of chronic lymphocytic leukaemia (CLL) benefited the most by FISH testing, which identified chromosomal aberrations beyond the capacity of CCS. FISH was least beneficial in myelodysplastic syndrome (MDS) where the highest concordance with CCS was exhibited. Acute lymphocytic leukaemia (ALL) demonstrated greater benefit with CCS. In addition, we found the following abnormalities to be most prevalent in HMs by FISH panel testing: RUNX1 (21q22) amplification in ALL, deletion of D13S319/LAMP1 (13q14) in CLL, CKS1B (1q21) amplification in multiple myeloma and deletion of EGR1/RPS14 (5q31/5q32) in MDS, consistent with the literature. Conclusions: In conclusion, FISH was found to be advantageous in only a subset of HMs and cannot completely replace CCS. Utilization of the two modalities in conjunction or independently should depend on the indicated HM for an optimal approach to detecting chromosomal aberrations. PMID:29286619

  2. Feasibility of a Semi-computerized Line Bisection Test for Unilateral Visual Neglect Assessment.

    PubMed

    Jee, H; Kim, J; Kim, C; Kim, T; Park, J

    2015-01-01

    Commonly used paper-and-pencil based test modalities for assessing the degree of unilateral visual neglect (ULN) in patients with hemispheric cerebral lesions consume human resources with a significant inter and intra-rater variability. To explore the feasibility of a semi-computerized electronic-pen based ULN assessment system (e-system) to improve assessment quality without altering the conventional user interface. Thirty cognitively healthy participants (HG) and 11 participants diagnosed with right-hemispheric lesion and unilateral visual neglect (NG) were recruited to evaluate the e-system. Line bisection tests (LBT) were repeatedly conducted twice for the inter-rater and intra-rater (reliability) comparisons. The LBT results were assessed by the e-system and the golden standard methods (manual rater assessment). The percent deviation (%), assessment duration (sec), and number of neglected line (each) were evaluated. The inter-rater comparisons of the assessed deviation (%) variable showed excellent interrater reliabilities (CCCs) ranging from .84 (.59 to .95 (p < .001)) to .99 (.90 to .99 (p < .001)) for HG and NG. The Bland Altman mean difference (B-A) plots with bias (95% LOA (limits of agreement)) showed similar agreements between the e-system and the raters ranging from -.04 % (-2.10 to 1.97) to 1.30 % (-2.23 to 4.84) for HG and NG. The effect sizes (ES), which show similarities between the assessment methods, yielded smaller ranges from .01 to .30 for HG and NG. The reliability (test-retest) comparisons showed similar assessment results between the e-system, rater 1, and rater 2. The manual rater assessment time ranging from 5.85 to 6.00 minutes and inter- and intraassessment variations were virtually eliminated with the e-system. The semi-computerized system with the conventional paper-and pencil user-interface showed valid and reliable assessment results. It may be a feasible replacement for the manual rater assessment modality even in a clinical setting.

  3. Canadian women's attitudes toward noninvasive prenatal testing of fetal DNA in maternal plasma (.).

    PubMed

    Pariente, Gali; Hasan, Lara; Gadot, Yifat; De Souza, Leanne R; Lebovic, Gerald; Berger, Howard

    2016-12-01

    To determine the perceptions and attitudes of Canadian women to Noninvasive Prenatal Testing of fetal DNA. A designed questionnaire was administered to women attending the outpatient antenatal clinic at a tertiary urban hospital. Attitudes to current and new prenatal screening modalities were assessed using a five-point Likert scale. Bowker's test of symmetry was used to compare individual responses regarding the two screening modalities. Changes in women's responses pre- and post-delivery were also compared. One hundred and twenty-nine women were enrolled in this study. 88% of women state that they would perform prenatal screening via fetal DNA in the maternal plasma if available. When compared to conventional screening, significantly less women believe that the NIPT should be available upon request for non-medical traits (36.4% versus 60.4%, p < 0.001). When compared to their answer before delivery, more women agreed that screening with fetal DNA in maternal plasma could be used in a negative way to select for desired non-medical traits such as gender. The use of fetal DNA in the maternal plasma is widely accepted in our Canadian population as a future method of noninvasive prenatal screening despite recognition of certain ethical concerns. This information can be used when implementing new genetic screening programs.

  4. Modal Testing of Seven Shuttle Cargo Elements for Space Station

    NASA Technical Reports Server (NTRS)

    Kappus, Kathy O.; Driskill, Timothy C.; Parks, Russel A.; Patterson, Alan (Technical Monitor)

    2001-01-01

    From December 1996 to May 2001, the Modal and Control Dynamics Team at NASA's Marshall Space Flight Center (MSFC) conducted modal tests on seven large elements of the International Space Station. Each of these elements has been or will be launched as a Space Shuttle payload for transport to the International Space Station (ISS). Like other Shuttle payloads, modal testing of these elements was required for verification of the finite element models used in coupled loads analyses for launch and landing. The seven modal tests included three modules - Node, Laboratory, and Airlock, and four truss segments - P6, P3/P4, S1/P1, and P5. Each element was installed and tested in the Shuttle Payload Modal Test Bed at MSFC. This unique facility can accommodate any Shuttle cargo element for modal test qualification. Flexure assemblies were utilized at each Shuttle-to-payload interface to simulate a constrained boundary in the load carrying degrees of freedom. For each element, multiple-input, multiple-output burst random modal testing was the primary approach with controlled input sine sweeps for linearity assessments. The accelerometer channel counts ranged from 252 channels to 1251 channels. An overview of these tests, as well as some lessons learned, will be provided in this paper.

  5. Dry coupling for whole-body small-animal photoacoustic computed tomography

    NASA Astrophysics Data System (ADS)

    Yeh, Chenghung; Li, Lei; Zhu, Liren; Xia, Jun; Li, Chiye; Chen, Wanyi; Garcia-Uribe, Alejandro; Maslov, Konstantin I.; Wang, Lihong V.

    2017-04-01

    We have enhanced photoacoustic computed tomography with dry acoustic coupling that eliminates water immersion anxiety and wrinkling of the animal and facilitates incorporating complementary modalities and procedures. The dry acoustic coupler is made of a tubular elastic membrane enclosed by a closed transparent water tank. The tubular membrane ensures water-free contact with the animal, and the closed water tank allows pressurization for animal stabilization. The dry coupler was tested using a whole-body small-animal ring-shaped photoacoustic computed tomography system. Dry coupling was found to provide image quality comparable to that of conventional water coupling.

  6. Initial treatment of sigmoid volvulous by colonoscopy.

    PubMed Central

    Starling, J R

    1979-01-01

    The initial management of acute, nonstrangulated sigmoid volvulous is to attempt proctosigmoidoscopic, rectal tube, or barium enema reduction and evacuation. If unsuccessful emergency surgery is necessary. The flexible colonoscope offers an additional therapeutic modality to effectuate preoperative reduction of the twisted sigmoid colon if attempts with conventional methods fail. Three cases of acute sigmoid volvulous are presented which illustrate for the first time successful reduction of acute sigmoid volvulous by colonoscopy after failure of the usual methods of treatment. Instead of emergency surgery all of these patients had elective resection with primary colocolostomy. Patients with acute sigmoid volvulous refractile to reduction by conventional modalities should have an attempt at flexible colonoscopic reduction. Images Fig. 1. Fig. 2. Fig. 3. Fig. 4. PMID:464675

  7. PRECISION MANAGEMENT OF LOCALIZED PROSTATE CANCER

    PubMed Central

    VanderWeele, David J.; Turkbey, Baris; Sowalsky, Adam G.

    2017-01-01

    Introduction The vast majority of men who are diagnosed with prostate cancer die of other causes, highlighting the importance of determining which patient has a risk of death from prostate cancer. Precision management of prostate cancer patients includes distinguishing which men have potentially lethal disease and employing strategies for determining which treatment modality appropriately balances the desire to achieve a durable response while preventing unnecessary overtreatment. Areas covered In this review, we highlight precision approaches to risk assessment and a context for the precision-guided application of definitive therapy. We focus on three dilemmas relevant to the diagnosis of localized prostate cancer: screening, the decision to treat, and postoperative management. Expert commentary In the last five years, numerous precision tools have emerged with potential benefit to the patient. However, to achieve optimal outcome, the decision to employ one or more of these tests must be considered in the context of prevailing conventional factors. Moreover, performance and interpretation of a molecular or imaging precision test remains practitioner-dependent. The next five years will witness increased marriage of molecular and imaging biomarkers for improved multi-modal diagnosis and discrimination of disease that is aggressive versus truly indolent. PMID:28133630

  8. High productivity mould robotic milling in Al-5083

    NASA Astrophysics Data System (ADS)

    Urresti, Iker; Arrazola, Pedro Jose; Ørskov, Klaus Bonde; Pelegay, Jose Angel

    2018-05-01

    Industrial serial robots were usually limited to welding, handling or spray painting operations until very recent years. However, some industries have already realized about their important capabilities in terms of flexibility, working space, adaptability and cost. Hence, currently they are seriously being considered to carry out certain metal machining tasks. Therefore, robot based machining is presented as a cost-saving and flexible manufacturing alternative compared to conventional CNC machines especially for roughing or even pre-roughing of large parts. Nevertheless, there are still some drawbacks usually referred as low rigidity, accuracy and repeatability. Thus, the process productivity is usually sacrificed getting low Material Removal Rates (MRR), and consequently not being competitive. Nevertheless, in this paper different techniques to obtain increased productivity are presented, though an appropriate selection of cutting strategies and parameters that are essential for it. During this research some rough milling tests in Al-5083 are presented where High Feed Milling (HFM) is implemented as productive cutting strategy and the experimental modal analysis named Tap-testing is used for the suitable choice of cutting conditions. Competitive productivity rates are experienced while process stability is checked through the cutting forces measurements in order to prove the effectiveness of the experimental modal analysis for robotic machining.

  9. Highly sensitive and multiplexed platforms for allergy diagnostics

    NASA Astrophysics Data System (ADS)

    Monroe, Margo R.

    Allergy is a disorder of the immune system caused by an immune response to otherwise harmless environmental allergens. Currently 20% of the US population is allergic and 90% of pediatric patients and 60% of adult patients with asthma have allergies. These percentages have increased by 18.5% in the past decade, with predicted similar trends for the future. Here we design sensitive, multiplexed platforms to detect allergen-specific IgE using the Interferometric Reflectance Imaging Sensor (IRIS) for various clinical settings. A microarray platform for allergy diagnosis allows for testing of specific IgE sensitivity to a multitude of allergens, while requiring only small volumes of patient blood sample. However, conventional fluorescent microarray technology is limited by i) the variation of probe immobilization, which hinders the ability to make quantitative, assertive, and statistically relevant conclusions necessary in immunodiagnostics and ii) the use of fluorophore labels, which is not suitable for some clinical applications due to the tendency of fluorophores to stick to blood particulates and require daily calibration methods. This calibrated fluorescence enhancement (CaFE) method integrates the low magnification modality of IRIS with enhanced fluorescence sensing in order to directly correlate immobilized probe (major allergens) density to allergen-specific IgE in patient serum. However, this platform only operates in processed serum samples, which is not ideal for point of care testing. Thus, a high magnification modality of IRIS was adapted as an alternative allergy diagnostic platform to automatically discriminate and size single nanoparticles bound to specific IgE in unprocessed, characterized human blood and serum samples. These features make IRIS an ideal candidate for clinical and diagnostic applications, such a POC testing. The high magnification (nanoparticle counting) modality in conjunction with low magnification of IRIS in a combined instrument offers four significant advantages compared to existing sensing technologies: IRIS i) corrects for any variation in probe immobilization, ii) detects proteins from attomolar to nanomolar concentrations in unprocessed biological samples, iii) unambiguously discriminates nanoparticles tags on a robust and physically large sensor area, iv) detects protein targets with conjugated nanoparticle tags (~40nm diameter), which minimally affect assay kinetics compared to conventional microparticle tagging methods, and v) utilizes components that make the instrument inexpensive, robust, and portable. This platform was successfully validated on patient serum and whole blood samples with documented allergy profiles (ImmunoCAPRTM, ThermoFisher Scientific).

  10. Potential of phase contrast x-ray imaging for detecting tumors in dense breast: initial phantom studies

    NASA Astrophysics Data System (ADS)

    Omoumi, Farid H.; Wu, Di; Guo, Yuran; Ghani, Muhammad U.; Li, Yuhua; Boyce, Kari E.; Liu, Hong

    2018-02-01

    The objective of this study is to demonstrate the potential of using the High-energy in-line phase contrast x-ray imaging to detect lesions that are indistinguishable by conventional x-ray mammography but are detectable by supplemental ultrasound screening within dense breasts. For this study, a custom-made prototype x-ray/ultrasound dualmodality phantom that mimics dense breast is created to include embedded carbon fiber disks with multiple diameters and thicknesses. The phase contrast image is acquired using a prototype at 120kVp, 67μA, exposure time of 16.7sec and focal spot size of 18.3μm with average glandular dose (AGD) of 0.3mGy under a geometric magnification of 2.48. The conventional x-ray image is acquired with a bench top system operating at 40kVp, 300μA, exposure time of 50sec and same AGD. The results demonstrate that conventional x-ray imaging is unable to detect any of the carbon fiber disks, while phase contrast imaging and ultrasonography are able to detect most or all of the disks under the applied experimental conditions. These results illustrate phase contrast imaging is capable of detecting targets in a dual-modality phantom which simulates lesions in dense breast tissue, when the simulated lesions are not distinguishable by conventional mammography. Therefore mammographic screening with phase contrast technique could eventually replace both x-ray and ultrasonography for screening detection of small lesions with microcalcification in dense breasts where pathologic lesions are masked due to highly glandular tissue. These results encourage further investigation using high glandular density phantoms to further evaluate the effectiveness of phase contrast imaging as a single modality test, which combines the advantages of both x-ray and ultrasound imaging in cancer screening of patients with dense breasts.

  11. Herbal remedies and functional foods used by cancer patients attending specialty oncology clinics in Trinidad.

    PubMed

    Clement, Yuri N; Mahase, Varune; Jagroop, Annelise; Kissoon, Kelly; Maharaj, Aarti; Mathura, Prashant; Quan, Chrys Mc; Ramadhin, Divya; Mohammed, Cherrista

    2016-10-21

    Cancer is a major disease worldwide, and many patients use complementary and alternative treatments. The purpose of this study was to identify the herbal remedies and functional foods used as complementary medicine by prostate, breast and colorectal cancer patients at speciality care facilities in Trinidad. We also sought to determine how patients rated the efficacy of these modalities compared with conventional treatment. A descriptive, cross-sectional survey was conducted using an interviewer-administered pilot-tested de novo questionnaire during the period June to August 2012 at two speciality treatment centres on the island. Data was analysed using χ 2 analyses. Among the 150 patients who reported use of herbal remedies/functional foods, soursop (Annona muricata L.) was the most popular; with 80.7 % using the leaves, bark, fruit and seeds on a regular basis. Other common herbal remedies/functional foods included wheatgrass (Triticum aestivum L.), saffron (Crocus sativus L.) and Aloe vera (L.) Burm. f. The most commonly used functional foods were beetroot (Beta vulgaris L.), carrots (Daucus carata L.) and papaya (Carica papaya L.) used by 43.3 % of patients; and these were mostly blended as a mixture. Herbal remedies and functional foods were used on a daily basis and patients believed that this modality was equally (32.0 %) or more efficacious (14.7 %) than conventional treatment. This survey identified the most common herbal remedies and functional foods used among prostate, breast and colorectal cancer patients in Trinidad. Although functional foods rarely pose a problem, herbs may interact with conventional chemotherapy and physicians need to inform patients regarding probable herb-drug interactions.

  12. A Standard Mammography Unit - Standard 3D Ultrasound Probe Fusion Prototype: First Results.

    PubMed

    Schulz-Wendtland, Rüdiger; Jud, Sebastian M; Fasching, Peter A; Hartmann, Arndt; Radicke, Marcus; Rauh, Claudia; Uder, Michael; Wunderle, Marius; Gass, Paul; Langemann, Hanna; Beckmann, Matthias W; Emons, Julius

    2017-06-01

    The combination of different imaging modalities through the use of fusion devices promises significant diagnostic improvement for breast pathology. The aim of this study was to evaluate image quality and clinical feasibility of a prototype fusion device (fusion prototype) constructed from a standard tomosynthesis mammography unit and a standard 3D ultrasound probe using a new method of breast compression. Imaging was performed on 5 mastectomy specimens from patients with confirmed DCIS or invasive carcinoma (BI-RADS ™ 6). For the preclinical fusion prototype an ABVS system ultrasound probe from an Acuson S2000 was integrated into a MAMMOMAT Inspiration (both Siemens Healthcare Ltd) and, with the aid of a newly developed compression plate, digital mammogram and automated 3D ultrasound images were obtained. The quality of digital mammogram images produced by the fusion prototype was comparable to those produced using conventional compression. The newly developed compression plate did not influence the applied x-ray dose. The method was not more labour intensive or time-consuming than conventional mammography. From the technical perspective, fusion of the two modalities was achievable. In this study, using only a few mastectomy specimens, the fusion of an automated 3D ultrasound machine with a standard mammography unit delivered images of comparable quality to conventional mammography. The device allows simultaneous ultrasound - the second important imaging modality in complementary breast diagnostics - without increasing examination time or requiring additional staff.

  13. A Highly Sensitive X-ray Imaging Modality for Hepatocellular Carcinoma Detection in Vitro

    PubMed Central

    Rand, Danielle; Walsh, Edward G.; Derdak, Zoltan; Wands, Jack R.; Rose-Petruck, Christoph

    2015-01-01

    Innovations that improve sensitivity and reduce cost are of paramount importance in diagnostic imaging. The novel x-ray imaging modality called Spatial Frequency Heterodyne Imaging (SFHI) is based on a linear arrangement of x-ray source, tissue, and x-ray detector, much like that of a conventional x-ray imaging apparatus. However, SFHI rests on a complete paradigm reversal compared to conventional x-ray absorption-based radiology: while scattered x-rays are carefully rejected in absorption-based x-ray radiology to enhance the image contrast, SFHI forms images exclusively from x-rays scattered by the tissue. In this study we use numerical processing to produce x-ray scatter images of Hepatocellular Carcinoma (HCC) labeled with a nanoparticle contrast agent. We subsequently compare the sensitivity of SFHI in this application to that of both conventional x-ray imaging and Magnetic Resonance Imaging (MRI). Although SFHI is still in the early stages of its development, our results show that the sensitivity of SFHI is an order of magnitude greater than that of absorption-based x-ray imaging and approximately equal to that of MRI. As x-ray imaging modalities typically have lower installation and service costs compared to MRI, SFHI could become a cost effective alternative to MRI, particularly in areas of the world with inadequate availability of MRI facilities. PMID:25559398

  14. Endoscopic Submucosal Dissection Using a Novel Versatile Knife: An Animal Feasibility Study (with Video)

    PubMed Central

    Kwon, Chang-Il; Kim, Gwangil; Kim, Won Hee; Ko, Kwang Hyun; Hong, Sung Pyo; Jeong, Seok; Lee, Don Haeng

    2014-01-01

    Background/Aims In order to reduce the procedure time and the number of accessory changes during endoscopic submucosal dissection (ESD), we developed a novel versatile knife, which has the combined advantages of several conventional knives. The aim of this study was to compare the efficacy, safety, and histological quality of ESD performed using this novel versatile knife and a combination of several conventional knives. Methods This was an in vivo animal study comparing two different modalities of ESD in mini-pigs. Completion time of each resection was documented, and the resected specimens were retrieved and evaluated for completeness. To assess the quality control of the procedures and adverse events, detailed histopathological examinations were performed. Results A total of 18 specimens were dissected by ESD safely and easily (nine specimens using the new versatile knife; nine specimens by mixing conventional knives). All resections were completed as en bloc resections. There was no significant difference in procedure time between the 2 modalities (456 seconds vs. 355 seconds, p=0.258) and cutting speed (1.983 mm2/sec vs. 1.57 mm2/sec, p=1.000). The rate of adverse events and histological quality did not statistically differ between the modalities. Conclusions ESD with a versatile knife appeared to be an easy, safe, and technically efficient method. PMID:25505721

  15. PubMed Central

    Schulz-Wendtland, Rüdiger; Jud, Sebastian M.; Fasching, Peter A.; Hartmann, Arndt; Radicke, Marcus; Rauh, Claudia; Uder, Michael; Wunderle, Marius; Gass, Paul; Langemann, Hanna; Beckmann, Matthias W.; Emons, Julius

    2017-01-01

    Aim The combination of different imaging modalities through the use of fusion devices promises significant diagnostic improvement for breast pathology. The aim of this study was to evaluate image quality and clinical feasibility of a prototype fusion device (fusion prototype) constructed from a standard tomosynthesis mammography unit and a standard 3D ultrasound probe using a new method of breast compression. Materials and Methods Imaging was performed on 5 mastectomy specimens from patients with confirmed DCIS or invasive carcinoma (BI-RADS ™ 6). For the preclinical fusion prototype an ABVS system ultrasound probe from an Acuson S2000 was integrated into a MAMMOMAT Inspiration (both Siemens Healthcare Ltd) and, with the aid of a newly developed compression plate, digital mammogram and automated 3D ultrasound images were obtained. Results The quality of digital mammogram images produced by the fusion prototype was comparable to those produced using conventional compression. The newly developed compression plate did not influence the applied x-ray dose. The method was not more labour intensive or time-consuming than conventional mammography. From the technical perspective, fusion of the two modalities was achievable. Conclusion In this study, using only a few mastectomy specimens, the fusion of an automated 3D ultrasound machine with a standard mammography unit delivered images of comparable quality to conventional mammography. The device allows simultaneous ultrasound – the second important imaging modality in complementary breast diagnostics – without increasing examination time or requiring additional staff. PMID:28713173

  16. A highly sensitive x-ray imaging modality for hepatocellular carcinoma detection in vitro

    DOE PAGES

    Rand, Danielle; Walsh, Edward G.; Derdak, Zoltan; ...

    2015-01-05

    Innovations that improve sensitivity and reduce cost are of paramount importance in diagnostic imaging. The novel x-ray imaging modality called Spatial Frequency Heterodyne Imaging (SFHI) is based on a linear arrangement of x-ray source, tissue, and x-ray detector, much like that of a conventional x-ray imaging apparatus. However, SFHI rests on a complete paradigm reversal compared to conventional x-ray absorption-based radiology: while scattered x-rays are carefully rejected in absorption-based x-ray radiology to enhance the image contrast, SFHI forms images exclusively from x-rays scattered by the tissue. Here in this study we use numerical processing to produce x-ray scatter images ofmore » Hepatocellular Carcinoma (HCC) labeled with a nanoparticle contrast agent. We subsequently compare the sensitivity of SFHI in this application to that of both conventional x-ray imaging and Magnetic Resonance Imaging (MRI). Although SFHI is still in the early stages of its development, our results show that the sensitivity of SFHI is an order of magnitude greater than that of absorption-based x-ray imaging and approximately equal to that of MRI. Lastly, as x-ray imaging modalities typically have lower installation and service costs compared to MRI, SFHI could become a cost effective alternative to MRI, particularly in areas of the world with inadequate availability of MRI facilities.« less

  17. Misremembering what you see or hear: Dissociable effects of modality on short- and long-term false recognition.

    PubMed

    Olszewska, Justyna M; Reuter-Lorenz, Patricia A; Munier, Emily; Bendler, Sara A

    2015-09-01

    False working memories readily emerge using a visual item-recognition variant of the converging associates task. Two experiments, manipulating study and test modality, extended prior working memory results by demonstrating a reliable false recognition effect (more false alarms to associatively related lures than to unrelated lures) within seconds of encoding in either the visual or auditory modality. However, false memories were nearly twice as frequent when study lists were seen than when they were heard, regardless of test modality, although study-test modality mismatch was generally disadvantageous (consistent with encoding specificity). A final experiment that varied study-test modality using a hybrid short- and long-term memory test (Flegal, Atkins & Reuter-Lorenz, 2010) replicated the auditory advantage in the short term but revealed a reversal in the long term: The false memory effect was greater in the auditory study-test condition than in the visual study-test condition. Thus, the same encoding conditions gave rise to an opposite modality advantage depending on whether recognition was tested under short-term or long-term memory conditions. Although demonstrating continuity in associative processing across delay, the results indicate that delay condition affects the availability of modality-dependent features of the memory trace and, thus, distinctiveness, leading to dissociable patterns of short- and long-term memory performance. (c) 2015 APA, all rights reserved).

  18. A comparison of paper-and-pencil and computerized forms of Line Orientation and Enhanced Cued Recall Tests.

    PubMed

    Aşkar, Petek; Altun, Arif; Cangöz, Banu; Cevik, Vildan; Kaya, Galip; Türksoy, Hasan

    2012-04-01

    The purpose of this study was to assess whether a computerized battery of neuropsychological tests could produce similar results as the conventional forms. Comparisons on 77 volunteer undergraduates were carried out with two neuropsychological tests: Line Orientation Test and Enhanced Cued Recall Test. Firstly, students were assigned randomly across the test medium (paper-and-pencil versus computerized). Secondly, the groups were given the same test in the other medium after a 30-day interval between tests. Results showed that the Enhanced Cued Recall Test-Computer-based did not correlate with the Enhanced Cued Recall Test-Paper-and-pencil results. Line Orientation Test-Computer-based scores, on the other hand, did correlate significantly with the Line Orientation Test-Paper-and-pencil version. In both tests, scores were higher on paper-and-pencil tests compared to computer-based tests. Total score difference between modalities was statistically significant for both Enhanced Cued Recall Tests and for the Line Orientation Test. In both computer-based tests, it took less time for participants to complete the tests.

  19. On Sloshing Modes in Equilateral-Polygonal-Section Containers

    NASA Astrophysics Data System (ADS)

    Hirata, Katsuya; Tanigawa, Hirochika; Yamamoto, Masahiro; Nakashima, Tohru; Funaki, Jiro

    Vertical sloshing is the liquid surface motion in a container forced to oscillate in the vertical direction. The present paper concerns the vertical sloshing in various equilateral-polygonal-section containers such as octagonal-, heptagonal-, hexagonal-, pentagonal-, square- and triangular-section containers together with a circular-section container, in order to generalise their sloshing modes. As a result, the authors classify the sloshing modes on the basis of the conventional circular-section-container sloshing modes. It is revealed that this modal classification has some advantages over that based on the conventional square-section-container sloshing modes. Furthermore, the stability diagrams for all the equilateral-polygonal-section containers are investigated by both experiments and computations. The present computation is based on a discrete singularity method. The proposed modal classification is useful to predict the eigen frequencies. Specifically speaking, it is found that the equivalent diameter de1 based on the hydraulic mean depth is the most adequate as a characteristic length scale to classify all the sloshing modes. The authors show a unified formula to predict the eigen frequencies, using de1 together with the proposed modal classification.

  20. 40 CFR 1042.505 - Testing engines using discrete-mode or ramped-modal duty cycles.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Testing engines using discrete-mode or...-IGNITION ENGINES AND VESSELS Test Procedures § 1042.505 Testing engines using discrete-mode or ramped-modal... the Clean Air Act. (a) You may perform steady-state testing with either discrete-mode or ramped-modal...

  1. 40 CFR 1039.505 - How do I test engines using steady-state duty cycles, including ramped-modal testing?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-state duty cycles, including ramped-modal testing? 1039.505 Section 1039.505 Protection of Environment... duty cycles, including ramped-modal testing? This section describes how to test engines under steady-state conditions. In some cases, we allow you to choose the appropriate steady-state duty cycle for an...

  2. A comparative overview of modal testing and system identification for control of structures

    NASA Technical Reports Server (NTRS)

    Juang, J.-N.; Pappa, R. S.

    1988-01-01

    A comparative overview is presented of the disciplines of modal testing used in structural engineering and system identification used in control theory. A list of representative references from both areas is given, and the basic methods are described briefly. Recent progress on the interaction of modal testing and control disciplines is discussed. It is concluded that combined efforts of researchers in both disciplines are required for unification of modal testing and system identification methods for control of flexible structures.

  3. SU-F-T-538: CyberKnife with MLC for Treatment of Large Volume Tumors: A Feasibility Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bichay, T; Mayville, A

    2016-06-15

    Purpose: CyberKnife is a well-documented modality for SRS and SBRT treatments. Typical tumors are small and 1–5 fractions are usually used. We determined the feasibility of using CyberKnife, with an InCise multileaf collimator option, for larger tumors undergoing standard dose and fractionation. The intent was to understand the limitation of using this modality for other external beam radiation treatments. Methods: Five tumors from different anatomical sites with volumes from 127.8 cc to 1,320.5 cc were contoured and planned on a Multiplan V5.1 workstation. The target average diameter ranged from 7 cm to 13 cm. The dose fractionation was 1.8–2.0 Gy/fractionmore » and 25–45 fractions for total doses of 45–81 Gy. The sites planned were: pancreas, head and neck, prostate, anal, and esophagus. The plans were optimized to meet conventional dose constraints based on various RTOG protocols for conventional fractionation. Results: The Multiplan treatment planning system successfully generated clinically acceptable plans for all sites studied. The resulting dose distributions achieved reasonable target coverage, all greater than 95%, and satisfactory normal tissue sparing. Treatment times ranged from 9 minutes to 38 minutes, the longest being a head and neck plan with dual targets receiving different doses and with multiple adjacent critical structures. Conclusion: CyberKnife, with the InCise multileaf collimation option, can achieve acceptable dose distributions in large volume tumors treated with conventional dose and fractionation. Although treatment times are greater than conventional accelerator time; target coverage and dose to critical structures can be kept within a clinically acceptable range. While time limitations exist, when necessary CyberKnife can provide an alternative to traditional treatment modalities for large volume tumors.« less

  4. Strain Modal Analysis of Small and Light Pipes Using Distributed Fibre Bragg Grating Sensors

    PubMed Central

    Huang, Jun; Zhou, Zude; Zhang, Lin; Chen, Juntao; Ji, Chunqian; Pham, Duc Truong

    2016-01-01

    Vibration fatigue failure is a critical problem of hydraulic pipes under severe working conditions. Strain modal testing of small and light pipes is a good option for dynamic characteristic evaluation, structural health monitoring and damage identification. Unique features such as small size, light weight, and high multiplexing capability enable Fibre Bragg Grating (FBG) sensors to measure structural dynamic responses where sensor size and placement are critical. In this paper, experimental strain modal analysis of pipes using distributed FBG sensors ispresented. Strain modal analysis and parameter identification methods are introduced. Experimental strain modal testing and finite element analysis for a cantilever pipe have been carried out. The analysis results indicate that the natural frequencies and strain mode shapes of the tested pipe acquired by FBG sensors are in good agreement with the results obtained by a reference accelerometer and simulation outputs. The strain modal parameters of a hydraulic pipe were obtained by the proposed strain modal testing method. FBG sensors have been shown to be useful in the experimental strain modal analysis of small and light pipes in mechanical, aeronautic and aerospace applications. PMID:27681728

  5. Ares I-X Launch Vehicle Modal Test Measurements and Data Quality Assessments

    NASA Technical Reports Server (NTRS)

    Templeton, Justin D.; Buehrle, Ralph D.; Gaspar, James L.; Parks, Russell A.; Lazor, Daniel R.

    2010-01-01

    The Ares I-X modal test program consisted of three modal tests conducted at the Vehicle Assembly Building at NASA s Kennedy Space Center. The first test was performed on the 71-foot 53,000-pound top segment of the Ares I-X launch vehicle known as Super Stack 5 and the second test was performed on the 66-foot 146,000- pound middle segment known as Super Stack 1. For these tests, two 250 lb-peak electro-dynamic shakers were used to excite bending and shell modes with the test articles resting on the floor. The third modal test was performed on the 327-foot 1,800,000-pound Ares I-X launch vehicle mounted to the Mobile Launcher Platform. The excitation for this test consisted of four 1000+ lb-peak hydraulic shakers arranged to excite the vehicle s cantilevered bending modes. Because the frequencies of interest for these modal tests ranged from 0.02 to 30 Hz, high sensitivity capacitive accelerometers were used. Excitation techniques included impact, burst random, pure random, and force controlled sine sweep. This paper provides the test details for the companion papers covering the Ares I-X finite element model calibration process. Topics to be discussed include test setups, procedures, measurements, data quality assessments, and consistency of modal parameter estimates.

  6. Effects of damping on mode shapes, volume 2

    NASA Technical Reports Server (NTRS)

    Gates, R. M.; Merchant, D. H.; Arnquist, J. L.

    1977-01-01

    Displacement, velocity, and acceleration admittances were calculated for a realistic NASTRAN structural model of space shuttle for three conditions: liftoff, maximum dynamic pressure and end of solid rocket booster burn. The realistic model of the orbiter, external tank, and solid rocket motors included the representation of structural joint transmissibilities by finite stiffness and damping elements. Data values for the finite damping elements were assigned to duplicate overall low-frequency modal damping values taken from tests of similar vehicles. For comparison with the calculated admittances, position and rate gains were computed for a conventional shuttle model for the liftoff condition. Dynamic characteristics and admittances for the space shuttle model are presented.

  7. Heart Rate Detection Using Microsoft Kinect: Validation and Comparison to Wearable Devices.

    PubMed

    Gambi, Ennio; Agostinelli, Angela; Belli, Alberto; Burattini, Laura; Cippitelli, Enea; Fioretti, Sandro; Pierleoni, Paola; Ricciuti, Manola; Sbrollini, Agnese; Spinsante, Susanna

    2017-08-02

    Contactless detection is one of the new frontiers of technological innovation in the field of healthcare, enabling unobtrusive measurements of biomedical parameters. Compared to conventional methods for Heart Rate (HR) detection that employ expensive and/or uncomfortable devices, such as the Electrocardiograph (ECG) or pulse oximeter, contactless HR detection offers fast and continuous monitoring of heart activities and provides support for clinical analysis without the need for the user to wear a device. This paper presents a validation study for a contactless HR estimation method exploiting RGB (Red, Green, Blue) data from a Microsoft Kinect v2 device. This method, based on Eulerian Video Magnification (EVM), Photoplethysmography (PPG) and Videoplethysmography (VPG), can achieve performance comparable to classical approaches exploiting wearable systems, under specific test conditions. The output given by a Holter, which represents the gold-standard device used in the test for ECG extraction, is considered as the ground-truth, while a comparison with a commercial smartwatch is also included. The validation process is conducted with two modalities that differ for the availability of a priori knowledge about the subjects' normal HR. The two test modalities provide different results. In particular, the HR estimation differs from the ground-truth by 2% when the knowledge about the subject's lifestyle and his/her HR is considered and by 3.4% if no information about the person is taken into account.

  8. Heart Rate Detection Using Microsoft Kinect: Validation and Comparison to Wearable Devices

    PubMed Central

    Agostinelli, Angela; Belli, Alberto; Cippitelli, Enea; Fioretti, Sandro; Pierleoni, Paola; Ricciuti, Manola

    2017-01-01

    Contactless detection is one of the new frontiers of technological innovation in the field of healthcare, enabling unobtrusive measurements of biomedical parameters. Compared to conventional methods for Heart Rate (HR) detection that employ expensive and/or uncomfortable devices, such as the Electrocardiograph (ECG) or pulse oximeter, contactless HR detection offers fast and continuous monitoring of heart activities and provides support for clinical analysis without the need for the user to wear a device. This paper presents a validation study for a contactless HR estimation method exploiting RGB (Red, Green, Blue) data from a Microsoft Kinect v2 device. This method, based on Eulerian Video Magnification (EVM), Photoplethysmography (PPG) and Videoplethysmography (VPG), can achieve performance comparable to classical approaches exploiting wearable systems, under specific test conditions. The output given by a Holter, which represents the gold-standard device used in the test for ECG extraction, is considered as the ground-truth, while a comparison with a commercial smartwatch is also included. The validation process is conducted with two modalities that differ for the availability of a priori knowledge about the subjects’ normal HR. The two test modalities provide different results. In particular, the HR estimation differs from the ground-truth by 2% when the knowledge about the subject’s lifestyle and his/her HR is considered and by 3.4% if no information about the person is taken into account. PMID:28767091

  9. 40 CFR 1045.505 - How do I test engines using discrete-mode or ramped-modal duty cycles?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false How do I test engines using discrete... MARINE ENGINES AND VESSELS Test Procedures § 1045.505 How do I test engines using discrete-mode or ramped... allow you to perform tests with either discrete-mode or ramped-modal sampling. You must use the modal...

  10. Dual-modality imaging

    NASA Astrophysics Data System (ADS)

    Hasegawa, Bruce; Tang, H. Roger; Da Silva, Angela J.; Wong, Kenneth H.; Iwata, Koji; Wu, Max C.

    2001-09-01

    In comparison to conventional medical imaging techniques, dual-modality imaging offers the advantage of correlating anatomical information from X-ray computed tomography (CT) with functional measurements from single-photon emission computed tomography (SPECT) or with positron emission tomography (PET). The combined X-ray/radionuclide images from dual-modality imaging can help the clinician to differentiate disease from normal uptake of radiopharmaceuticals, and to improve diagnosis and staging of disease. In addition, phantom and animal studies have demonstrated that a priori structural information from CT can be used to improve quantification of tissue uptake and organ function by correcting the radionuclide data for errors due to photon attenuation, partial volume effects, scatter radiation, and other physical effects. Dual-modality imaging therefore is emerging as a method of improving the visual quality and the quantitative accuracy of radionuclide imaging for diagnosis of patients with cancer and heart disease.

  11. Effect of E85 on RCCI Performance and Emissions on a Multi-Cylinder Light-Duty Diesel Engine - SAE World Congress

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Curran, Scott; Hanson, Reed M; Wagner, Robert M

    2012-01-01

    This paper investigates the effect of E85 on load expansion and FTP modal point emissions indices under reactivity controlled compression ignition (RCCI) operation on a light-duty multi-cylinder diesel engine. A General Motors (GM) 1.9L four-cylinder diesel engine with the stock compression ratio of 17.5:1, common rail diesel injection system, high-pressure exhaust gas recirculation (EGR) system and variable geometry turbocharger was modified to allow for port fuel injection with gasoline or E85. Controlling the fuel reactivity in-cylinder by the adjustment of the ratio of premixed low-reactivity fuel (gasoline or E85) to direct injected high reactivity fuel (diesel fuel) has been shownmore » to extend the operating range of high-efficiency clean combustion (HECC) compared to the use of a single fuel alone as in homogeneous charge compression ignition (HCCI) or premixed charge compression ignition (PCCI). The effect of E85 on the Ad-hoc federal test procedure (FTP) modal points is explored along with the effect of load expansion through the light-duty diesel speed operating range. The Ad-hoc FTP modal points of 1500 rpm, 1.0bar brake mean effective pressure (BMEP); 1500rpm, 2.6bar BMEP; 2000rpm, 2.0bar BMEP; 2300rpm, 4.2bar BMEP; and 2600rpm, 8.8bar BMEP were explored. Previous results with 96 RON unleaded test gasoline (UTG-96) and ultra-low sulfur diesel (ULSD) showed that with stock hardware, the 2600rpm, 8.8bar BMEP modal point was not obtainable due to excessive cylinder pressure rise rate and unstable combustion both with and without the use of EGR. Brake thermal efficiency and emissions performance of RCCI operation with E85 and ULSD is explored and compared against conventional diesel combustion (CDC) and RCCI operation with UTG 96 and ULSD.« less

  12. Efficacy of E-Learning via the Website of Tehran University of Medical Sciences for Diagnosing Tooth Discolorations and Treatment Planning by Senior Dental Students.

    PubMed

    Hashemikamangar, Sedighe Sadat; Yazdanpanah, Farnoosh; Mirzaii, Mansoore; Yazdani, Reza; Karazifard, Mohammad Javad; Yasini, Esmaeil

    2016-08-01

    The efficacy of methods like e-learning as a supplement to traditional face-to-face instruction needs to be evaluated in dental courses. This study aimed to assess the efficacy of posting case presentations on one of the educational websites of  the virtual school of Tehran University of Medical Sciences called "SARMAD" to enhance the ability of senior dental students to diagnose tooth discolorations and offer treatment plans. This experimental study had a pre-test/post-test control group design and was conducted on 63 senior dental students. After filling out the primary questionnaire and obtaining a written informed consent, students participated in a pre-test and were then randomly divided into two groups of intervention and control. Fifteen case presentations were posted on the university website (SARMAD) during 6 weeks and discussed. Then, students participated in a post-test. Students' perspectives and their satisfaction with the website were assessed by a questionnaire. For ethical purposes, the same program was also offered to the controls. The post-test score was significantly higher than the pre-test score in the intervention group (P<0.001); but in the control group, the post-test score was only slightly higher than the pre-test score (P=0.128). In the intervention group, 70% stated that they would suggest this method as an efficient educational modality; 93.3% stated that this method would be beneficial as a supplement to conventional education; 16.7% ranked the SARMAD website excellent, 30% ranked it good, 33.3% acceptable, 16.7% moderate and 3.3 poor. It appears that this instructional modality may be efficiently used as a supplement to traditional instruction in undergraduate dental curricula.

  13. Free-free and fixed base modal survey tests of the Space Station Common Module Prototype

    NASA Technical Reports Server (NTRS)

    Driskill, T. C.; Anderson, J. B.; Coleman, A. D.

    1992-01-01

    This paper describes the testing aspects and the problems encountered during the free-free and fixed base modal surveys completed on the original Space Station Common Module Prototype (CMP). The CMP is a 40-ft long by 14.5-ft diameter 'waffle-grid' cylinder built by the Boeing Company and housed at the Marshall Space Flight Center (MSFC) near Huntsville, AL. The CMP modal survey tests were conducted at MSFC by the Dynamics Test Branch. The free-free modal survey tests (June '90 to Sept. '90) included interface verification tests (IFVT), often referred to as impedance measurements, mass-additive testing and linearity studies. The fixed base modal survey tests (Feb. '91 to April '91), including linearity studies, were conducted in a fixture designed to constrain the CMP in 7 total degrees-of-freedom at five trunnion interfaces (two primary, two secondary, and the keel). The fixture also incorporated an airbag off-load system designed to alleviate the non-linear effects of friction in the primary and secondary trunnion interfaces. Numerous test configurations were performed with the objective of providing a modal data base for evaluating the various testing methodologies to verify dynamic finite element models used for input to coupled load analysis.

  14. Fixed Base Modal Survey of the MPCV Orion European Service Module Structural Test Article

    NASA Technical Reports Server (NTRS)

    Winkel, James P.; Akers, J. C.; Suarez, Vicente J.; Staab, Lucas D.; Napolitano, Kevin L.

    2017-01-01

    Recently, the MPCV Orion European Service Module Structural Test Article (E-STA) underwent sine vibration testing using the multi-axis shaker system at NASA GRC Plum Brook Station Mechanical Vibration Facility (MVF). An innovative approach using measured constraint shapes at the interface of E-STA to the MVF allowed high-quality fixed base modal parameters of the E-STA to be extracted, which have been used to update the E-STA finite element model (FEM), without the need for a traditional fixed base modal survey. This innovative approach provided considerable program cost and test schedule savings. This paper documents this modal survey, which includes the modal pretest analysis sensor selection, the fixed base methodology using measured constraint shapes as virtual references and measured frequency response functions, and post-survey comparison between measured and analysis fixed base modal parameters.

  15. Traditional neighborhood development (TND) guidelines

    DOT National Transportation Integrated Search

    2000-08-01

    A Traditional Neighborhood Development (TND) is a human scale, walkable community with moderate to high residential densities and a mixed use core. Compared with conventional suburban developments, TNDs have a higher potential to increase modal split...

  16. Comparison of Modal Analysis Methods Applied to a Vibro-Acoustic Test Article

    NASA Technical Reports Server (NTRS)

    Pritchard, Jocelyn; Pappa, Richard; Buehrle, Ralph; Grosveld, Ferdinand

    2001-01-01

    Modal testing of a vibro-acoustic test article referred to as the Aluminum Testbed Cylinder (ATC) has provided frequency response data for the development of validated numerical models of complex structures for interior noise prediction and control. The ATC is an all aluminum, ring and stringer stiffened cylinder, 12 feet in length and 4 feet in diameter. The cylinder was designed to represent typical aircraft construction. Modal tests were conducted for several different configurations of the cylinder assembly under ambient and pressurized conditions. The purpose of this paper is to present results from dynamic testing of different ATC configurations using two modal analysis software methods: Eigensystem Realization Algorithm (ERA) and MTS IDEAS Polyreference method. The paper compares results from the two analysis methods as well as the results from various test configurations. The effects of pressurization on the modal characteristics are discussed.

  17. 40 CFR 86.1362-2007 - Steady-state testing with a ramped-modal cycle.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-modal cycle. 86.1362-2007 Section 86.1362-2007 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate Exhaust Test Procedures § 86.1362-2007 Steady-state testing with a ramped-modal cycle. This section...

  18. 40 CFR 86.1362-2010 - Steady-state testing with a ramped-modal cycle.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-modal cycle. 86.1362-2010 Section 86.1362-2010 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... (CONTINUED) Emission Regulations for New Otto-Cycle and Diesel Heavy-Duty Engines; Gaseous and Particulate Exhaust Test Procedures § 86.1362-2010 Steady-state testing with a ramped-modal cycle. This section...

  19. Estimation of modal parameters using bilinear joint time frequency distributions

    NASA Astrophysics Data System (ADS)

    Roshan-Ghias, A.; Shamsollahi, M. B.; Mobed, M.; Behzad, M.

    2007-07-01

    In this paper, a new method is proposed for modal parameter estimation using time-frequency representations. Smoothed Pseudo Wigner-Ville distribution which is a member of the Cohen's class distributions is used to decouple vibration modes completely in order to study each mode separately. This distribution reduces cross-terms which are troublesome in Wigner-Ville distribution and retains the resolution as well. The method was applied to highly damped systems, and results were superior to those obtained via other conventional methods.

  20. Performance of normal adults and children on central auditory diagnostic tests and their corresponding visual analogs.

    PubMed

    Bellis, Teri James; Ross, Jody

    2011-09-01

    It has been suggested that, in order to validate a diagnosis of (C)APD (central auditory processing disorder), testing using direct cross-modal analogs should be performed to demonstrate that deficits exist solely or primarily in the auditory modality (McFarland and Cacace, 1995; Cacace and McFarland, 2005). This modality-specific viewpoint is controversial and not universally accepted (American Speech-Language-Hearing Association [ASHA], 2005; Musiek et al, 2005). Further, no such analogs have been developed to date, and neither the feasibility of such testing in normally functioning individuals nor the concurrent validity of cross-modal analogs has been established. The purpose of this study was to investigate the feasibility of cross-modal testing by examining the performance of normal adults and children on four tests of central auditory function and their corresponding visual analogs. In addition, this study investigated the degree to which concurrent validity of auditory and visual versions of these tests could be demonstrated. An experimental repeated measures design was employed. Participants consisted of two groups (adults, n=10; children, n=10) with normal and symmetrical hearing sensitivity, normal or corrected-to-normal visual acuity, and no family or personal history of auditory/otologic, language, learning, neurologic, or related disorders. Visual analogs of four tests in common clinical use for the diagnosis of (C)APD were developed (Dichotic Digits [Musiek, 1983]; Frequency Patterns [Pinheiro and Ptacek, 1971]; Duration Patterns [Pinheiro and Musiek, 1985]; and the Random Gap Detection Test [RGDT; Keith, 2000]). Participants underwent two 1 hr test sessions separated by at least 1 wk. Order of sessions (auditory, visual) and tests within each session were counterbalanced across participants. ANOVAs (analyses of variance) were used to examine effects of group, modality, and laterality (for the Dichotic/Dichoptic Digits tests) or response condition (for the auditory and visual Frequency Patterns and Duration Patterns tests). Pearson product-moment correlations were used to investigate relationships between auditory and visual performance. Adults performed significantly better than children on the Dichotic/Dichoptic Digits tests. Results also revealed a significant effect of modality, with auditory better than visual, and a significant modality×laterality interaction, with a right-ear advantage seen for the auditory task and a left-visual-field advantage seen for the visual task. For the Frequency Patterns test and its visual analog, results revealed a significant modality×response condition interaction, with humming better than labeling for the auditory version but the reversed effect for the visual version. For Duration Patterns testing, visual performance was significantly poorer than auditory performance. Due to poor test-retest reliability and ceiling effects for the auditory and visual gap-detection tasks, analyses could not be performed. No cross-modal correlations were observed for any test. Results demonstrated that cross-modal testing is at least feasible using easily accessible computer hardware and software. The lack of any cross-modal correlations suggests independent processing mechanisms for auditory and visual versions of each task. Examination of performance in individuals with central auditory and pan-sensory disorders is needed to determine the utility of cross-modal analogs in the differential diagnosis of (C)APD. American Academy of Audiology.

  1. Melorheostosis of the Foot: A Case Report of A rare entity with a Review of Multimodality Imaging Emphasizing the Importance of Conventional Radiography in Diagnosis.

    PubMed

    Ashish, Gulia; Shashikant, Juvekar; Ajay, Puri; Subhash, Desai

    2016-01-01

    Melorheostosis is a benign bone dysplasia affecting predominantly the appendicular skeleton and adjoining soft tissues. The diagnosis can be established on plain radiographs alone and advanced imaging modalities can be avoided. We hereby report a rare case of melorheostosis affecting the foot with a review of the role of various imaging modalities in diagnosis of this rare bone dysplasia. We present the case of a 29 years old man who was diagnosed with melorheostosis affecting his left foot. The patient presented to the outpatient department of our tertiary care referral hospital with complains of pain in the left ankle and foot with imaging and evaluation done at a primary center. The radiograph revealed an irregular, longitudinal extraosseous hyperostosis along the body of the calcaneum and the metacarpals which was consistent with the classical radiological description of melorheostosis. The CT, MRI and bone scan findings corroborated our primary diagnosis. The purpose of this case report is to review the features of this rare disorder affecting the foot, on multiple imaging modalities and emphasizing the role of conventional radiology in its diagnosis.

  2. Melorheostosis of the Foot: A Case Report of A rare entity with a Review of Multimodality Imaging Emphasizing the Importance of Conventional Radiography in Diagnosis

    PubMed Central

    Ashish, Gulia; Shashikant, Juvekar; Ajay, Puri; Subhash, Desai

    2016-01-01

    Introduction: Melorheostosis is a benign bone dysplasia affecting predominantly the appendicular skeleton and adjoining soft tissues. The diagnosis can be established on plain radiographs alone and advanced imaging modalities can be avoided. We hereby report a rare case of melorheostosis affecting the foot with a review of the role of various imaging modalities in diagnosis of this rare bone dysplasia. Case Report: We present the case of a 29 years old man who was diagnosed with melorheostosis affecting his left foot. The patient presented to the outpatient department of our tertiary care referral hospital with complains of pain in the left ankle and foot with imaging and evaluation done at a primary center. The radiograph revealed an irregular, longitudinal extraosseous hyperostosis along the body of the calcaneum and the metacarpals which was consistent with the classical radiological description of melorheostosis. The CT, MRI and bone scan findings corroborated our primary diagnosis. Conclusion: The purpose of this case report is to review the features of this rare disorder affecting the foot, on multiple imaging modalities and emphasizing the role of conventional radiology in its diagnosis. PMID:27299136

  3. Ares I-X Flight Test Vehicle: Stack 5 Modal Test

    NASA Technical Reports Server (NTRS)

    Buehrle, Ralph D.; Templeton, Justin D.; Reaves, Mercedes C.; Horta, Lucas G.; Gaspar, James L.; Bartolotta, Paul A.; Parks, Russel A.; Lazor, Danel R.

    2010-01-01

    Ares I-X was the first flight test vehicle used in the development of NASA's Ares I crew launch vehicle. The Ares I-X used a 4-segment reusable solid rocket booster from the Space Shuttle heritage with mass simulators for the 5th segment, upper stage, crew module and launch abort system. Three modal tests were defined to verify the dynamic finite element model of the Ares I-X flight test vehicle. Test configurations included two partial stacks and the full Ares I-X flight test vehicle on the Mobile Launcher Platform. This report focuses on the first modal test that was performed on the top section of the vehicle referred to as Stack 5, which consisted of the spacecraft adapter, service module, crew module and launch abort system simulators. This report describes the test requirements, constraints, pre-test analysis, test operations and data analysis for the Ares I-X Stack 5 modal test.

  4. Ares I-X Flight Test Vehicle:Stack 1 Modal Test

    NASA Technical Reports Server (NTRS)

    Buehrle, Ralph D.; Templeton, Justin D.; Reaves, Mercedes C.; Horta, Lucas G.; Gaspar, James L.; Bartolotta, Paul A.; Parks, Russel A.; Lazor, Daniel R.

    2010-01-01

    Ares I-X was the first flight test vehicle used in the development of NASA s Ares I crew launch vehicle. The Ares I-X used a 4-segment reusable solid rocket booster from the Space Shuttle heritage with mass simulators for the 5th segment, upper stage, crew module and launch abort system. Three modal tests were defined to verify the dynamic finite element model of the Ares I-X flight test vehicle. Test configurations included two partial stacks and the full Ares I-X flight test vehicle on the Mobile Launcher Platform. This report focuses on the second modal test that was performed on the middle section of the vehicle referred to as Stack 1, which consisted of the subassembly from the 5th segment simulator through the interstage. This report describes the test requirements, constraints, pre-test analysis, test operations and data analysis for the Ares I-X Stack 1 modal test.

  5. CT angiography of the renal arteries and veins: normal anatomy and variants.

    PubMed

    Hazırolan, Tuncay; Öz, Meryem; Türkbey, Barış; Karaosmanoğlu, Ali Devrim; Oğuz, Berna Sayan; Canyiğit, Murat

    2011-03-01

    Conventional angiography has long been regarded as gold standard imaging modality for evaluation of the renal vasculature. Introduction of multidetector computed tomography (MDCT) angiography had a groundbreaking impact on evaluation of the renal vessels and is gradually replacing conventional angiography as standard imaging. Herein, we review and illustrate the normal and variant anatomy of renal vessels with special emphasis on imaging protocols and reconstruction techniques in MDCT.

  6. Integration of multi-modal public transportation systems.

    DOT National Transportation Integrated Search

    2013-05-01

    Transit ridership may be sensitive to fares, travel times, waiting times, and access times, among other factors. Thus, : elastic demands are considered in formulations for maximizing the system welfare for conventional and flexible bus : services. Tw...

  7. Multishaker modal testing

    NASA Technical Reports Server (NTRS)

    Craig, R. R., Jr.

    1983-01-01

    Procedures for improving the modal modeling of structures using test data and to determine appropriate analytical models based on substructure experimental data were explored. Two related research topics were considered in modal modeling: using several independently acquired columns of frequency response data, and modal modeling using simultaneous multi-point excitation. In component mode synthesis modeling, the emphasis is on determining the best way to employ complex modes and residuals.

  8. Study on the effect of carbon nanotube coating on the refractive index sensing sensitivity of fiber modal interferometer

    NASA Astrophysics Data System (ADS)

    Zhang, Ya-nan; Xie, Wen-ge; Wang, Jianzhang; Wang, Pengzhao

    2018-01-01

    Refractive index sensing of liquid is important in the domain of chemistry and biology. Fiber optical sensors provide an excellent way to measure the refractive index due to their feasible integration to other fiber optics components, high sensitivity, small size, and distributed sensing. However, conventional optical sensors have different shortages. To find a practical way to measure the refractive index of liquid, this paper intended to combine Carbon Nanotube (CNT) with non-core fiber (NCF) to prepare a kind of modal interferometer sensor and to explore the effect of CNT coating on refractive index sensing properties of the modal interferometer. Firstly, a structure of single mode non-core single mode (SNS) fiber with a CNT film coating was proposed and simulated. The simulation results showed that the CNT coating could improve the refractive index sensitivity of the interferometer sensor. Then in the experiment part, the CNT solution was fabricated and deposited onto the NCF, and a refractive index sensing system was built to examine the property of the CNT-coated SNS interferometer sensor. During the experiment, the influence factors of sensitivity were summarized by testing the sensing performance under different conditions, and it was demonstrated that the CNT coating could improve the contrast of the interference spectrum, and also had the possibility to increase the refractive index sensitivity of the interferometer sensor.

  9. Immunotherapy for lung cancer: advances and prospects.

    PubMed

    Yang, Li; Wang, Liping; Zhang, Yi

    2016-01-01

    Lung cancer is the most commonly diagnosed cancer as well as the leading cause of cancer-related deaths worldwide. To date, surgery is the first choice treatment, but most clinically diagnosed cases are inoperable. While chemotherapy and/or radiotherapy are the next considered options for such cases, these treatment modalities have adverse effects and are sometimes lethal to patients. Thus, new effective strategies with minimal side effects are urgently needed. Cancer immunotherapy provides either active or passive immunity to target tumors. Multiple immunotherapy agents have been proposed and tested for potential therapeutic benefit against lung cancer, and some pose fewer side effects as compared to conventional chemotherapy and radiotherapy. In this article, we discuss studies focusing on interactions between lung cancer and the immune system, and we place an emphasis on outcome evidence in order to create a knowledge base well-grounded in clinical reality. Overall, this review highlights the need for new lung cancer treatment options, with much ground to be paved for future advances in the field. We believe that immunotherapy agents alone or with other forms of treatment can be recognized as next modality of lung cancer treatment.

  10. Oligometastatic prostate cancer: shaping the definition with molecular imaging and an improved understanding of tumor biology.

    PubMed

    Joice, Gregory A; Rowe, Steven P; Pienta, Kenneth J; Gorin, Michael A

    2017-11-01

    The aim of this review is to discuss how novel imaging modalities and molecular markers are shaping the definition of oligometastatic prostate cancer. To effectively classify a patient as having oligometastatic prostate cancer, diagnostic tests must be sensitive enough to detect subtle sites of metastatic disease. Conventional imaging modalities can readily detect widespread polymetastatic disease but do not have the sensitivity necessary to reliably classify patients as oligometastatic. Molecular imaging using both metabolic- and molecularly-targeted radiotracers has demonstrated great promise in aiding in our ability to define the oligometastatic state. Perhaps the most promising data to date have been generated with radiotracers targeting prostate-specific membrane antigen. In addition, early studies are beginning to define biologic markers in the oligometastatic state that may be indicative of disease with minimal metastatic potential. Recent developments in molecular imaging have allowed for improved detection of metastatic prostate cancer allowing for more accurate staging of patients with oligometastatic disease. Future development of biologic markers may assist in defining the oligometastatic state and determining prognosis.

  11. Comparison of size modulation and conventional standard automated perimetry with the 24-2 test protocol in glaucoma patients

    NASA Astrophysics Data System (ADS)

    Hirasawa, Kazunori; Shoji, Nobuyuki; Kasahara, Masayuki; Matsumura, Kazuhiro; Shimizu, Kimiya

    2016-05-01

    This prospective randomized study compared test results of size modulation standard automated perimetry (SM-SAP) performed with the Octopus 600 and conventional SAP (C-SAP) performed with the Humphrey Field Analyzer (HFA) in glaucoma patients. Eighty-eight eyes of 88 glaucoma patients underwent SM-SAP and C-SAP tests with the Octopus 600 24-2 Dynamic and HFA 24-2 SITA-Standard, respectively. Fovea threshold, mean defect, and square loss variance of SM-SAP were significantly correlated with the corresponding C-SAP indices (P < 0.001). The false-positive rate was slightly lower, and false-negative rate slightly higher, with SM-SAP than C-SAP (P = 0.002). Point-wise threshold values obtained with SM-SAP were moderately to strongly correlated with those obtained with C-SAP (P < 0.001). The correlation coefficients of the central zone were significantly lower than those of the middle to peripheral zone (P = 0.031). The size and depth of the visual field (VF) defect were smaller (P = 0.039) and greater (P = 0.043), respectively, on SM-SAP than on C-SAP. Although small differences were observed in VF sensitivity in the central zone, the defect size and depth and the reliability indices between SM-SAP and C-SAP, global indices of the two testing modalities were well correlated.

  12. CM-2 Environmental / Modal Testing of Spacehab Racks

    NASA Technical Reports Server (NTRS)

    McNelis, Mark E.; Goodnight, Thomas W.; Farkas, Michael A.

    2001-01-01

    Combined environmental/modal vibration testing has been implemented at the NASA Glenn Research Center's Structural Dynamics Laboratory. The benefits of combined vibration testing are that it facilitates test article modal characterization and vibration qualification testing. The Combustion Module-2 (CM-2) is a space experiment that launches on Shuttle mission STS 107 in the SPACEHAB Research Double Module. The CM-2 flight hardware is integrated into a SPACEHAB single and double rack. CM-2 rack level combined vibration testing was recently completed on a shaker table to characterize the structure's modal response and verify the random vibration response. Control accelerometers and limit force gauges, located between the fixture and rack interface, were used to verify the input excitation. Results of the testing were used to verify the loads and environments for flight on the Shuttle.

  13. Identification of Nasal Bone Fractures on Conventional Radiography and Facial CT: Comparison of the Diagnostic Accuracy in Different Imaging Modalities and Analysis of Interobserver Reliability.

    PubMed

    Baek, Hye Jin; Kim, Dong Wook; Ryu, Ji Hwa; Lee, Yoo Jin

    2013-09-01

    There has been no study to compare the diagnostic accuracy of an experienced radiologist with a trainee in nasal bone fracture. To compare the diagnostic accuracy between conventional radiography and computed tomography (CT) for the identification of nasal bone fractures and to evaluate the interobserver reliability between a staff radiologist and a trainee. A total of 108 patients who underwent conventional radiography and CT after acute nasal trauma were included in this retrospective study. Two readers, a staff radiologist and a second-year resident, independently assessed the results of the imaging studies. Of the 108 patients, the presence of a nasal bone fracture was confirmed in 88 (81.5%) patients. The number of non-depressed fractures was higher than the number of depressed fractures. In nine (10.2%) patients, nasal bone fractures were only identified on conventional radiography, including three depressed and six non-depressed fractures. CT was more accurate as compared to conventional radiography for the identification of nasal bone fractures as determined by both readers (P <0.05), all diagnostic indices of an experienced radiologist were similar to or higher than those of a trainee, and κ statistics showed moderate agreement between the two diagnostic tools for both readers. There was no statistical difference in the assessment of interobserver reliability for both imaging modalities in the identification of nasal bone fractures. For the identification of nasal bone fractures, CT was significantly superior to conventional radiography. Although a staff radiologist showed better values in the identification of nasal bone fracture and differentiation between depressed and non-depressed fractures than a trainee, there was no statistically significant difference in the interpretation of conventional radiography and CT between a radiologist and a trainee.

  14. Fluid mass and thermal loading effects on the modal characteristics of space shuttle main engine liquid oxygen inlet splitter vanes

    NASA Technical Reports Server (NTRS)

    Panossian, H. V.; Boehnlein, J. J.

    1987-01-01

    An analysis and evaluation of experimental modal survey test data on the variations of modal characteristics induced by pressure and thermal loading events are presented. Extensive modal survey tests were carried out on a Space Shuttle Main Engine (SSME) test article using liquid nitrogen under cryogenic temperatures and high pressures. The results suggest that an increase of pressure under constant cryogenic temperature or a decrease of temperature under high pressure induces an upward shift of frequencies of various modes of the structures.

  15. Analyser-based mammography using single-image reconstruction.

    PubMed

    Briedis, Dahliyani; Siu, Karen K W; Paganin, David M; Pavlov, Konstantin M; Lewis, Rob A

    2005-08-07

    We implement an algorithm that is able to decode a single analyser-based x-ray phase-contrast image of a sample, converting it into an equivalent conventional absorption-contrast radiograph. The algorithm assumes the projection approximation for x-ray propagation in a single-material object embedded in a substrate of approximately uniform thickness. Unlike the phase-contrast images, which have both directional bias and a bias towards edges present in the sample, the reconstructed images are directly interpretable in terms of the projected absorption coefficient of the sample. The technique was applied to a Leeds TOR[MAM] phantom, which is designed to test mammogram quality by the inclusion of simulated microcalcifications, filaments and circular discs. This phantom was imaged at varying doses using three modalities: analyser-based synchrotron phase-contrast images converted to equivalent absorption radiographs using our algorithm, slot-scanned synchrotron imaging and imaging using a conventional mammography unit. Features in the resulting images were then assigned a quality score by volunteers. The single-image reconstruction method achieved higher scores at equivalent and lower doses than the conventional mammography images, but no improvement of visualization of the simulated microcalcifications, and some degradation in image quality at reduced doses for filament features.

  16. Incidence of Wife Abuse in Incestuous Families.

    ERIC Educational Resources Information Center

    Truesdell, Donna L.; And Others

    1986-01-01

    Investigates a largely uncharted dynamic in the literature--the incidence of wife abuse among incestuous families--and suggests that professional caregivers reevaluate conventional treatment modalities that are based on certain assumptions regarding the mother's role in incest. (Author)

  17. Imaging of oxygenation in 3D tissue models with multi-modal phosphorescent probes

    NASA Astrophysics Data System (ADS)

    Papkovsky, Dmitri B.; Dmitriev, Ruslan I.; Borisov, Sergei

    2015-03-01

    Cell-penetrating phosphorescence based probes allow real-time, high-resolution imaging of O2 concentration in respiring cells and 3D tissue models. We have developed a panel of such probes, small molecule and nanoparticle structures, which have different spectral characteristics, cell penetrating and tissue staining behavior. The probes are compatible with conventional live cell imaging platforms and can be used in different detection modalities, including ratiometric intensity and PLIM (Phosphorescence Lifetime IMaging) under one- or two-photon excitation. Analytical performance of these probes and utility of the O2 imaging method have been demonstrated with different types of samples: 2D cell cultures, multi-cellular spheroids from cancer cell lines and primary neurons, excised slices from mouse brain, colon and bladder tissue, and live animals. They are particularly useful for hypoxia research, ex-vivo studies of tissue physiology, cell metabolism, cancer, inflammation, and multiplexing with many conventional fluorophors and markers of cellular function.

  18. Co-production of Health enabled by next generation personal health systems.

    PubMed

    Boye, Niels

    2012-01-01

    This paper describes the theoretical principles for the establishment of a parallel and complementary modality of healthcare delivery - named Coproduction of Health (CpH). This service-model activates digital data, information, and knowledge about health, healthy choices, and the individuals' health-state and computes through personalized models context-aware communication and advice. "Lightweight technologies" (smartphones, tablets, application stores) would serve as the technology close to the end-users (citizens, patients, clients, customers), connecting them with "big data" in conventionally and non-conventionally organized data repositories. The CpH modality aims at providing synergies between professional healthcare, selfcare, informal care and provides data-fusion from several sources such as health characteristics of consumer goods, from sensors, actuators, and health related data-repositories, and turns this into "health added value" for the individual. A theoretical business model respecting healthcare values, ethics, and legal foundation is also sketched out.

  19. Oriented Scintillation Spectrometer Experiment (OSSE). Revision A. Volume 1

    DTIC Science & Technology

    1988-05-19

    SYSTEM-LEVEL ENVIRONMENTAL TESTS ................... 108 3.5.1 OPERATION REPORT, PROOF MODEL STRUCTURE TESTS.. .108 3.5.1.1 PROOF MODEL MODAL SURVEY...81 3-21 ALIGNMENT ERROR BUDGET, FOV, A4 ................ 82 3-22 ALIGNMENT ERROR BUDGET, ROTATION AXIS, A4 ...... 83 3-23 OSSE PROOF MODEL MODAL SURVEY...PROOF MODEL MODAL SURVEY .................. 112 3-27-1 OSSE PROOF MODEL STATIC LOAD TEST ............. 116 3-27-2 OSSE PROOF MODEL STATIC LOAD TEST

  20. Modal data for the BARC challenge problem Test Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rohe, Daniel Peter

    Modal testing was performed on the uncut BARC structure as a whole and broken into its two sub-assemblies. The structure was placed on soft foam during the test. Excitation was provided with a small modal hammer attached to an actuator. Responses were measured using a 3D Scanning Laser Doppler Vibrometer. Data, shapes, and geometry from this test can be downloaded in Universal File Format from the Sandia Connect SharePoint site.

  1. Cross contrast multi-channel image registration using image synthesis for MR brain images.

    PubMed

    Chen, Min; Carass, Aaron; Jog, Amod; Lee, Junghoon; Roy, Snehashis; Prince, Jerry L

    2017-02-01

    Multi-modal deformable registration is important for many medical image analysis tasks such as atlas alignment, image fusion, and distortion correction. Whereas a conventional method would register images with different modalities using modality independent features or information theoretic metrics such as mutual information, this paper presents a new framework that addresses the problem using a two-channel registration algorithm capable of using mono-modal similarity measures such as sum of squared differences or cross-correlation. To make it possible to use these same-modality measures, image synthesis is used to create proxy images for the opposite modality as well as intensity-normalized images from each of the two available images. The new deformable registration framework was evaluated by performing intra-subject deformation recovery, intra-subject boundary alignment, and inter-subject label transfer experiments using multi-contrast magnetic resonance brain imaging data. Three different multi-channel registration algorithms were evaluated, revealing that the framework is robust to the multi-channel deformable registration algorithm that is used. With a single exception, all results demonstrated improvements when compared against single channel registrations using the same algorithm with mutual information. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. To increase controllability of a large flexible antenna by modal optimization

    NASA Astrophysics Data System (ADS)

    Wang, Feng; Wang, Pengpeng; Jiang, Wenjian

    2017-12-01

    Large deployable antennas are widely used in aerospace engineering to meet the envelop limit of rocket fairing. The high flexibility and low damping of antenna has proposed critical requirement not only for stability control of the antenna itself, but also for attitude control of the satellite. This paper aims to increase controllability of a large flexible antenna by modal optimization. Firstly, Sensitivity analysis of antenna modal frequencies to stiffness of support structure and stiffness of scanning mechanism are conducted respectively. Secondly, Modal simulation results of antenna frequencies are given, influences of scanning angles on moment of inertia and modal frequencies are evaluated, and modal test is carried out to validate the simulation results. All the simulation and test results show that, after modal optimization the modal characteristic of the large deployable antenna meets the controllability requirement well.

  3. Study design for a randomised controlled trial to explore the modality and mechanism of Tai Chi in the pulmonary rehabilitation of chronic obstructive pulmonary disease.

    PubMed

    Fu, Juan-Juan; Min, Jie; Yu, Peng-Ming; McDonald, Vanessa M; Mao, Bing

    2016-08-04

    Although pulmonary rehabilitation (PR) is associated with significant clinical benefits in chronic obstructive pulmonary disease (COPD) and has been recommended by guidelines, PR with conventional exercise training has not been widely applied in the clinic because of its inherent limitations. Alternative exercise such as Tai Chi has been investigated and the results are promising. However, the strengths and weaknesses of the exercise modality of Tai Chi, conventional PR and a combination of Tai Chi and conventional PR and the possible mechanisms underlying Tai Chi exercise remain unclear. This study aims to address the above research gaps in a well-designed clinical trial. This study is a single-blind, randomised controlled trial. Participants with stable COPD will be recruited and randomly assigned to one of four groups receiving Tai Chi exercise, conventional PR using a total body recumbent stepper (TBRS), combined Tai Chi and TBRS, or usual care (control) in a 1:1:1:1 ratio. Participants will perform 30 min of supervised exercise three times a week for 8 weeks; they will receive sequential follow-ups until 12 months after recruitment. The primary outcome will be health-related quality of life as measured by the St George's Respiratory Questionnaire. Secondary outcomes will include 6 min walking distance, pulmonary function, the modified Medical Research Council Dyspnoea Scale, the COPD Assessment Test, the Hospital Anxiety and Depression Scale, the Berg Balance Scale, exacerbation frequency during the study period, and systemic inflammatory and immune markers. Ethics approval has been granted by the Clinical Trial and Biomedical Ethics Committee of West China Hospital of Sichuan University (No TCM-2015-82). Written informed consent will be obtained from each participant before any procedures are performed. The study findings will be published in peer-reviewed journals and presented at national and international conferences. ChiCTR-IOR-15006874; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. CM-2 Environmental/Modal Testing of SPACEHAB Racks

    NASA Technical Reports Server (NTRS)

    McNelis, Mark E.; Goodnight, Thomas W.

    2001-01-01

    Combined environmental/modal vibration testing has been implemented at the NASA Glenn Research Center's Structural Dynamics Laboratory. The benefits of combined vibration testing are that it facilitates test article modal characterization and vibration qualification testing. The Combustion Module-2 (CM-2) is a space experiment that will launch on shuttle mission STS-107 in the SPACEHAB Research Double Module. The CM-2 flight hardware is integrated into a SPACEHAB single and double rack. CM-2 rack-level combined vibration testing was recently completed on a shaker table to characterize the structure's modal response and verify the random vibration response. Control accelerometers and limit force gauges, located between the fixture and rack interface, were used to verify the input excitation. Results of the testing were used to verify the loads and environments for flight on the shuttles.

  5. Structural Modeling of a Five-Meter Thin Film Inflatable Antenna/Concentrator

    NASA Technical Reports Server (NTRS)

    Smalley, Kurt B.; Tinker, Michael L.; Taylor, W. Scott; Brunty, Joseph A. (Technical Monitor)

    2002-01-01

    Inflatable structures have been the subject of renewed interest in recent years for space applications such as communications antennas, solar thermal propulsion, and space solar power. A major advantage of using inflatable structures in space is their extremely light weight. An obvious second advantage is on-orbit deployability and related space savings in the launch configuration. A recent technology demonstrator flight for inflatable structures was the Inflatable Antenna Experiment (IAE) that was deployed on orbit from the Shuttle Orbiter. Although difficulty was encountered in the inflation/deployment phase, the flight was successful overall and provided valuable experience in the use of such structures. Several papers on static structural analysis of inflated cylinders have been written, describing different techniques such as linear shell theory, and nonlinear and variational methods, but very little work had been done in dynamics of inflatable structures until recent years. In 1988 Leonard indicated that elastic beam bending modes could be utilized in approximating lower-order frequencies of inflatable beams. Main, et al. wrote a very significant 1995 paper describing results of modal tests of inflated cantilever beams and the determination of effective material properties. Changes in material properties for different pressures were also discussed, and the beam model was used in a more complex structure. The paper demonstrated that conventional finite element analysis packages could be very useful in the analysis of complex inflatable structures. The purposes of this paper are to discuss the methodology for dynamically characterizing a large 5-meter thin film inflatable reflector, and to discuss the test arrangement and results. Nonlinear finite element modal results are compared to modal test data. The work is significant and of considerable interest to researchers because of 1) the large size of the structure, making it useful for scaling studies, and 2) application of commercially available finite element software for modeling pressurized thin-film structures.

  6. Comparison of NASTRAN analysis with ground vibration results of UH-60A NASA/AEFA test configuration

    NASA Technical Reports Server (NTRS)

    Idosor, Florentino; Seible, Frieder

    1990-01-01

    Preceding program flight tests, a ground vibration test and modal test analysis of a UH-60A Black Hawk helicopter was conducted by Sikorsky Aircraft to complement the UH-60A test plan and NASA/ARMY Modern Technology Rotor Airloads Program. The 'NASA/AEFA' shake test configuration was tested for modal frequencies and shapes and compared with its NASTRAN finite element model counterpart to give correlative results. Based upon previous findings, significant differences in modal data existed and were attributed to assumptions regarding the influence of secondary structure contributions in the preliminary NASTRAN modeling. An analysis of an updated finite element model including several secondary structural additions has confirmed that the inclusion of specific secondary components produces a significant effect on modal frequency and free-response shapes and improves correlations at lower frequencies with shake test data.

  7. High-Temperature Modal Survey of a Hot-Structure Control Surface

    NASA Technical Reports Server (NTRS)

    Spivey, Natalie Dawn

    2010-01-01

    Ground vibration tests or modal surveys are routinely conducted for supporting flutter analysis for subsonic and supersonic vehicles; however, for hypersonic vehicle applications, thermoelastic vibration testing techniques are not well established and are not routinely performed for supporting hypersonic flutter analysis. New high-temperature material systems, fabrication technologies and high-temperature sensors expand the opportunities to develop advanced techniques for performing ground vibration tests at elevated temperatures. High-temperature materials have the unique property of increasing in stiffness when heated. When these materials are incorporated into a hot-structure, which includes metallic components that decrease in stiffness with increasing temperature, the interaction between the two materials systems needs to be understood because that interaction could ultimately affect the hypersonic flutter analysis. Performing a high-temperature modal survey will expand the research database for hypersonics and will help build upon the understanding of the dual material interaction. This paper will discuss the vibration testing of the Carbon-Silicon Carbide Ruddervator Subcomponent Test Article which is a truncated version of the full-scale X-37 hot-structure control surface. In order to define the modal characteristics of the test article during the elevated-temperature modal survey, two series of room-temperature modal test configurations had to be performed. The room-temperature test series included one with the test article suspended from a bungee cord (free-free) and the second with it mounted on the strongback (fixed boundary condition) in NASA Dryden's Flight Loads Lab large nitrogen test chamber.

  8. The possibility of application of spiral brain computed tomography to traumatic brain injury.

    PubMed

    Lim, Daesung; Lee, Soo Hoon; Kim, Dong Hoon; Choi, Dae Seub; Hong, Hoon Pyo; Kang, Changwoo; Jeong, Jin Hee; Kim, Seong Chun; Kang, Tae-Sin

    2014-09-01

    The spiral computed tomography (CT) with the advantage of low radiation dose, shorter test time required, and its multidimensional reconstruction is accepted as an essential diagnostic method for evaluating the degree of injury in severe trauma patients and establishment of therapeutic plans. However, conventional sequential CT is preferred for the evaluation of traumatic brain injury (TBI) over spiral CT due to image noise and artifact. We aimed to compare the diagnostic power of spiral facial CT for TBI to that of conventional sequential brain CT. We evaluated retrospectively the images of 315 traumatized patients who underwent both brain CT and facial CT simultaneously. The hemorrhagic traumatic brain injuries such as epidural hemorrhage, subdural hemorrhage, subarachnoid hemorrhage, and contusional hemorrhage were evaluated in both images. Statistics were performed using Cohen's κ to compare the agreement between 2 imaging modalities and sensitivity, specificity, positive predictive value, and negative predictive value of spiral facial CT to conventional sequential brain CT. Almost perfect agreement was noted regarding hemorrhagic traumatic brain injuries between spiral facial CT and conventional sequential brain CT (Cohen's κ coefficient, 0.912). To conventional sequential brain CT, sensitivity, specificity, positive predictive value, and negative predictive value of spiral facial CT were 92.2%, 98.1%, 95.9%, and 96.3%, respectively. In TBI, the diagnostic power of spiral facial CT was equal to that of conventional sequential brain CT. Therefore, expanded spiral facial CT covering whole frontal lobe can be applied to evaluate TBI in the future. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Correlation mapping microscopy

    NASA Astrophysics Data System (ADS)

    McGrath, James; Alexandrov, Sergey; Owens, Peter; Subhash, Hrebesh M.; Leahy, Martin J.

    2015-03-01

    Changes in the microcirculation are associated with conditions such as Raynauds disease. Current modalities used to assess the microcirculation such as nailfold capillaroscopy are limited due to their depth ambiguity. A correlation mapping technique was recently developed to extend the capabilities of Optical Coherence Tomography to generate depth resolved images of the microcirculation. Here we present the extension of this technique to microscopy modalities, including confocal microscopy. It is shown that this correlation mapping microscopy technique can extend the capabilities of conventional microscopy to enable mapping of vascular networks in vivo with high spatial resolution.

  10. Development of the mathematical model for design and verification of acoustic modal analysis methods

    NASA Astrophysics Data System (ADS)

    Siner, Alexander; Startseva, Maria

    2016-10-01

    To reduce the turbofan noise it is necessary to develop methods for the analysis of the sound field generated by the blade machinery called modal analysis. Because modal analysis methods are very difficult and their testing on the full scale measurements are very expensive and tedious it is necessary to construct some mathematical models allowing to test modal analysis algorithms fast and cheap. At this work the model allowing to set single modes at the channel and to analyze generated sound field is presented. Modal analysis of the sound generated by the ring array of point sound sources is made. Comparison of experimental and numerical modal analysis results is presented at this work.

  11. Blind identification of the Millikan Library from earthquake data considering soil–structure interaction

    USGS Publications Warehouse

    Ghahari, S. F.; Abazarsa, F.; Avci, O.; Çelebi, Mehmet; Taciroglu, E.

    2016-01-01

    The Robert A. Millikan Library is a reinforced concrete building with a basement level and nine stories above the ground. Located on the campus of California Institute of Technology (Caltech) in Pasadena California, it is among the most densely instrumented buildings in the U.S. From the early dates of its construction, it has been the subject of many investigations, especially regarding soil–structure interaction effects. It is well accepted that the structure is significantly interacting with the surrounding soil, which implies that the true foundation input motions cannot be directly recorded during earthquakes because of inertial effects. Based on this limitation, input–output modal identification methods are not applicable to this soil–structure system. On the other hand, conventional output-only methods are typically based on the unknown input signals to be stationary whitenoise, which is not the case for earthquake excitations. Through the use of recently developed blind identification (i.e. output-only) methods, it has become possible to extract such information from only the response signals because of earthquake excitations. In the present study, we employ such a blind identification method to extract the modal properties of the Millikan Library. We present some modes that have not been identified from force vibration tests in several studies to date. Then, to quantify the contribution of soil–structure interaction effects, we first create a detailed Finite Element (FE) model using available information about the superstructure; and subsequently update the soil–foundation system's dynamic stiffnesses at each mode such that the modal properties of the entire soil–structure system agree well with those obtained via output-only modal identification.

  12. Development of Modal Test Techniques for Validation of a Solar Sail Design

    NASA Technical Reports Server (NTRS)

    Gaspar, James L.; Mann, Troy; Behun, Vaughn; Wilkie, W. Keats; Pappa, Richard

    2004-01-01

    This paper focuses on the development of modal test techniques for validation of a solar sail gossamer space structure design. The major focus is on validating and comparing the capabilities of various excitation techniques for modal testing solar sail components. One triangular shaped quadrant of a solar sail membrane was tested in a 1 Torr vacuum environment using various excitation techniques including, magnetic excitation, and surface-bonded piezoelectric patch actuators. Results from modal tests performed on the sail using piezoelectric patches at different positions are discussed. The excitation methods were evaluated for their applicability to in-vacuum ground testing and to the development of on orbit flight test techniques. The solar sail membrane was tested in the horizontal configuration at various tension levels to assess the variation in frequency with tension in a vacuum environment. A segment of a solar sail mast prototype was also tested in ambient atmospheric conditions using various excitation techniques, and these methods are also assessed for their ground test capabilities and on-orbit flight testing.

  13. Using Response Surface Methods to Correlate the Modal Test of an Inflatable Test Article

    NASA Technical Reports Server (NTRS)

    Gupta, Anju

    2013-01-01

    This paper presents a practical application of response surface methods (RSM) to correlate a finite element model of a structural modal test. The test article is a quasi-cylindrical inflatable structure which primarily consists of a fabric weave, with an internal bladder and metallic bulkheads on either end. To mitigate model size, the fabric weave was simplified by representing it with shell elements. The task at hand is to represent the material behavior of the weave. The success of the model correlation is measured by comparing the four major modal frequencies of the analysis model to the four major modal frequencies of the test article. Given that only individual strap material properties were provided and material properties of the overall weave were not available, defining the material properties of the finite element model became very complex. First it was necessary to determine which material properties (modulus of elasticity in the hoop and longitudinal directions, shear modulus, Poisson's ratio, etc.) affected the modal frequencies. Then a Latin Hypercube of the parameter space was created to form an efficiently distributed finite case set. Each case was then analyzed with the results input into RSM. In the resulting response surface it was possible to see how each material parameter affected the modal frequencies of the analysis model. If the modal frequencies of the analysis model and its corresponding parameters match the test with acceptable accuracy, it can be said that the model correlation is successful.

  14. Analysis of structural dynamic data from Skylab. Volume 2: Skylab analytical and test model data

    NASA Technical Reports Server (NTRS)

    Demchak, L.; Harcrow, H.

    1976-01-01

    The orbital configuration test modal data, analytical test correlation modal data, and analytical flight configuration modal data are presented. Tables showing the generalized mass contributions (GMCs) for each of the thirty tests modes are given along with the two dimensional mode shape plots and tables of GMCs for the test correlated analytical modes. The two dimensional mode shape plots for the analytical modes and uncoupled and coupled modes of the orbital flight configuration at three development phases of the model are included.

  15. Estimating free-body modal parameters from tests of a constrained structure

    NASA Technical Reports Server (NTRS)

    Cooley, Victor M.

    1993-01-01

    Hardware advances in suspension technology for ground tests of large space structures provide near on-orbit boundary conditions for modal testing. Further advances in determining free-body modal properties of constrained large space structures have been made, on the analysis side, by using time domain parameter estimation and perturbing the stiffness of the constraints over multiple sub-tests. In this manner, passive suspension constraint forces, which are fully correlated and therefore not usable for spectral averaging techniques, are made effectively uncorrelated. The technique is demonstrated with simulated test data.

  16. TNF-alpha antagonists and thalidomide for the management of gastrointestinal Behçet's syndrome refractory to the conventional treatment modalities: a case series and review of the literature.

    PubMed

    Hatemi, Ibrahim; Hatemi, Gulen; Pamuk, Omer Nuri; Erzin, Yusuf; Celik, Aykut Ferhat

    2015-01-01

    Gastrointestinal involvement of Behçet's syndrome is usually treated with glucocorticoids, 5-aminosalicylic acid compounds and azathioprine. However, some patients are refractory to these conventional therapy modalities. In this paper we report our experience on 13 patients with gastrointestinal involvement of Behçet's syndrome who were refractory to the conventional therapy and who were treated with TNF-alpha antagonists and/or thalidomide. We reviewed the charts of our Behçet's syndrome patients with gastrointestinal involvement and identified those who were treated with TNF-alpha antagonists and/or thalidomide. Demographic features, previous and concomitant drugs, previous surgery, time to remission and duration of remission were tabulated. We also performed a systematic review of publications on gastrointestinal involvement of Behçet's syndrome patients treated with TNF-alpha antagonists and/or thalidomide. Among our 64 patients with gastrointestinal involvement of Behçet's syndrome, we identified 13 (20%) (7 women, 6 men, mean age 27.4±9.4) who had been treated with TNF-alpha antagonists and/or thalidomide. Their previous medications were glucocorticoids (13/13), azathioprine (13/13), 5-aminosalicylic acid derivatives (3/13) and budesonide (1/13). Clinical and endoscopic remission was obtained in 10 patients. One patient died with sepsis. The systematic literature search revealed 91 cases who had used TNF-alpha antagonists and 15 who had used thalidomide. Among the patients who had received TNF-alpha antagonists, clinical remission was obtained in 47/91 patients (51%), while endoscopic remission was observed in 21/46 (45%) who had a control colonoscopy. One fifth of our Behçet's syndrome patients with gastrointestinal involvement were refractory to conventional treatment modalities. Remission was obtained with TNF-alpha antagonists and/or thalidomide in about 75% of the cases.

  17. Comparative study of different osteotomy modalities in maxillary distraction osteogenesis for cleft lip and palate.

    PubMed

    Yu, Hongbo; Wang, Xudong; Fang, Bing; Shen, Steve Guofang

    2012-11-01

    Conventional maxillary distraction osteogenesis and anterior maxillary segmental distraction were applied in the treatment of severe maxillary hypoplasia secondary to cleft clip and palate. The aim of the present study was to compare the difference between these 2 osteotomy modalities used for rigid external distraction. Ten patients with severe maxillary hypoplasia secondary to CLP were enrolled in our study. They were randomly divided into 2 groups. Conventional maxillary distraction osteogenesis was performed in 5 patients and anterior maxillary segmental distraction in 5 patients. The preoperative and postoperative lateral cephalograms were compared, and cephalometric analysis was performed. The independent sample t test was used to evaluate the differences between the 2 groups. All patients healed uneventfully, and the maxillae moved forward satisfactorily. The sella-nasion-point A angles, nasion-point A-Frankfort horizontal plane angles, overjets, and 0-meridian to subnasale distances had increased significantly after distraction osteogenesis. Significant differences were found in the changes in palatal length between the 2 groups (P < .05). A mean increase of 7.50 mm in palatal length was found in the anterior maxillary segmental distraction group. No significant difference in the changes in palatopharyngeal depth or soft palatal length was found. With the ability of increasing the palatal and arch length, avoiding changes in palatopharyngeal depth, and preserving palatopharyngeal closure function, anterior maxillary segmental distraction has great value in the treatment of maxillary hypoplasia secondary to CLP. It is a promising and valuable technique in this potentially complicated procedure. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Modal Survey of ETM-3, A 5-Segment Derivative of the Space Shuttle Solid Rocket Booster

    NASA Technical Reports Server (NTRS)

    Nielsen, D.; Townsend, J.; Kappus, K.; Driskill, T.; Torres, I.; Parks, R.

    2005-01-01

    The complex interactions between internal motor generated pressure oscillations and motor structural vibration modes associated with the static test configuration of a Reusable Solid Rocket Motor have potential to generate significant dynamic thrust loads in the 5-segment configuration (Engineering Test Motor 3). Finite element model load predictions for worst-case conditions were generated based on extrapolation of a previously correlated 4-segment motor model. A modal survey was performed on the largest rocket motor to date, Engineering Test Motor #3 (ETM-3), to provide data for finite element model correlation and validation of model generated design loads. The modal survey preparation included pretest analyses to determine an efficient analysis set selection using the Effective Independence Method and test simulations to assure critical test stand component loads did not exceed design limits. Historical Reusable Solid Rocket Motor modal testing, ETM-3 test analysis model development and pre-test loads analyses, as well as test execution, and a comparison of results to pre-test predictions are discussed.

  19. Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film.

    PubMed

    De Melo, Daniela Pita; Cruz, Adriana Dibo; Melo, Saulo Leonardo Sousa; De Farias, Julyanna Filgueiras GonçAlves; Haiter-Neto, Francisco; De Almeida, Solange Maria

    2015-04-01

    To compare intraoral Phosphor Stimulable Plate digital system and intraoral film using different tube settings on incipient proximal caries detection. Five blocks, with five teeth each, were radiographically examined using phosphor plates and F-speed films. The images were acquired in 07 different tube potentials from 50-80 kV. The films were digitized. Three oral radiologists scored the images for the presence of caries using a 5-point rating scale. The areas under ROC curve were calculated. The influence of tube kilovoltage was verified by ANOVA and pair wise comparisons performed using Tukey test. Mean ROC curve areas varied from 0.446-0.628 for digital images and 0.494-0.559 for conventional images. The tube setting of 70 kV presented the best result both for digital and conventional images. Considering the image type separately, 70 kV scored highest followed by 75 and 65 kV for digital images (p=0.084). For conventional image modality, even though 70 kV presented the best result, it did not differ significantly from 80 kV, not differing from 60 and 55 kV, which did not differ from 75, 65 and 50 kV (p=0.53). Phosphor plate digital images seem to be more susceptible to tube setting potential variations then digitized film images.

  20. Ground vibration tests of a high fidelity truss for verification of on orbit damage location techniques

    NASA Technical Reports Server (NTRS)

    Kashangaki, Thomas A. L.

    1992-01-01

    This paper describes a series of modal tests that were performed on a cantilevered truss structure. The goal of the tests was to assemble a large database of high quality modal test data for use in verification of proposed methods for on orbit model verification and damage detection in flexible truss structures. A description of the hardware is provided along with details of the experimental setup and procedures for 16 damage cases. Results from selected cases are presented and discussed. Differences between ground vibration testing and on orbit modal testing are also described.

  1. High-Temperature Modal Survey of a Hot-Structure Control Surface

    NASA Technical Reports Server (NTRS)

    Spivey, Natalie D.

    2011-01-01

    Ground vibration tests are routinely conducted for supporting flutter analysis for subsonic and supersonic vehicles; however, for hypersonic vehicles, thermoelastic vibration testing techniques are neither well established nor routinely performed. New high-temperature material systems, fabrication technologies and high-temperature sensors expand the opportunities to develop advanced techniques for performing ground vibration tests at elevated temperatures. When high-temperature materials, which increase in stiffness when heated, are incorporated into a hot-structure that contains metallic components that decrease in stiffness when heated, the interaction between those materials can affect the hypersonic flutter analysis. A high-temperature modal survey will expand the research database for hypersonics and improve the understanding of this dual-material interaction. This report discusses the vibration testing of the carbon-silicon carbide Ruddervator Subcomponent Test Article, which is a truncated version of a full-scale hot-structure control surface. Two series of room-temperature modal test configurations were performed in order to define the modal characteristics of the test article during the elevated-temperature modal survey: one with the test article suspended from a bungee cord (free-free) and the second with it mounted on the strongback (fixed boundary). Testing was performed in the NASA Dryden Flight Research Center Flight Loads Laboratory Large Nitrogen Test Chamber.

  2. Hybrid-modality high-resolution imaging: for diagnostic biomedical imaging and sensing for disease diagnosis

    NASA Astrophysics Data System (ADS)

    Murukeshan, Vadakke M.; Hoong Ta, Lim

    2014-11-01

    Medical diagnostics in the recent past has seen the challenging trend to come up with dual and multi-modality imaging for implementing better diagnostic procedures. The changes in tissues in the early disease stages are often subtle and can occur beneath the tissue surface. In most of these cases, conventional types of medical imaging using optics may not be able to detect these changes easily due to its penetration depth of the orders of 1 mm. Each imaging modality has its own advantages and limitations, and the use of a single modality is not suitable for every diagnostic applications. Therefore the need for multi or hybrid-modality imaging arises. Combining more than one imaging modalities overcomes the limitation of individual imaging method and integrates the respective advantages into a single setting. In this context, this paper will be focusing on the research and development of two multi-modality imaging platforms. The first platform combines ultrasound and photoacoustic imaging for diagnostic applications in the eye. The second platform consists of optical hyperspectral and photoacoustic imaging for diagnostic applications in the colon. Photoacoustic imaging is used as one of the modalities in both platforms as it can offer deeper penetration depth compared to optical imaging. The optical engineering and research challenges in developing the dual/multi-modality platforms will be discussed, followed by initial results validating the proposed scheme. The proposed schemes offer high spatial and spectral resolution imaging and sensing, and is expected to offer potential biomedical imaging solutions in the near future.

  3. Structural imaging of mild traumatic brain injury may not be enough: overview of functional and metabolic imaging of mild traumatic brain injury.

    PubMed

    Shin, Samuel S; Bales, James W; Edward Dixon, C; Hwang, Misun

    2017-04-01

    A majority of patients with traumatic brain injury (TBI) present as mild injury with no findings on conventional clinical imaging methods. Due to this difficulty of imaging assessment on mild TBI patients, there has been much emphasis on the development of diffusion imaging modalities such as diffusion tensor imaging (DTI). However, basic science research in TBI shows that many of the functional and metabolic abnormalities in TBI may be present even in the absence of structural damage. Moreover, structural damage may be present at a microscopic and molecular level that is not detectable by structural imaging modality. The use of functional and metabolic imaging modalities can provide information on pathological changes in mild TBI patients that may not be detected by structural imaging. Although there are various differences in protocols of positron emission tomography (PET), single photon emission computed tomography (SPECT), functional magnetic resonance imaging (fMRI), electroencephalography (EEG), and magnetoencephalography (MEG) methods, these may be important modalities to be used in conjunction with structural imaging in the future in order to detect and understand the pathophysiology of mild TBI. In this review, studies of mild TBI patients using these modalities that detect functional and metabolic state of the brain are discussed. Each modality's advantages and disadvantages are compared, and potential future applications of using combined modalities are explored.

  4. Integrative Medicine Preferences Among Coccidioidomycosis (Valley Fever) Patients.

    PubMed

    Short, Jack H; Bradley, Constance; Blair, Janis E; Stewart, Terry D; Burns, Mark W; Patron, Roberto L; Millstine, Denise M

    2017-02-01

    To understand the extent and modalities of integrative medicine strategies that patients with coccidioidomycosis (valley fever) have incorporated into their treatment regimens. A direct patient survey was distributed, with 100 unique responses, at a single infectious diseases clinic at an academic medical center in Arizona. Eligible patients, defined as those with confirmed coccidioidomycosis or currently under evaluation, were polled on their personal use of 36 integrative medicine modalities. Patients were also asked to indicate their level of fatigue on a 10-point scale in an attempt to correlate levels of fatigue to use of specific integrative medicine modalities. Of the patients surveyed, 64% had used at least one integrative medicine modality, and 53% used two or more, along with conventional medical therapy. The top three modalities were nutrition (39%), massage (27%), and breathing exercises (26%). The mean reported fatigue level was 4.7 on a 10-point scale, with a standard deviation of 3.0. There was no statistically significant association between use of a specific modality and reported level of fatigue. Nearly two thirds of patients (64%) surveyed had used at least one integrative medicine modality throughout the course of their therapy. Clinicians are probably unaware of the extent to which many patients, including this population, have embraced integrative medicine. Awareness of patients' goal and preferences is valuable in shared clinical decision making.

  5. Wake Shield Facility Modal Survey Test in Vibration Acoustic Test Facility

    NASA Image and Video Library

    1991-10-09

    Astronaut Ronald M. Sega stands beside the University of Houston's Wake Shield Facility before it undergoes a Modal Survey Test in the Vibration and Acoustic Test Facility Building 49, prior to being flown on space shuttle mission STS-60.

  6. Vibration Analysis Of Automotive Structures Using Holographic Interferometry

    NASA Astrophysics Data System (ADS)

    Brown, G. M.; Wales, R. R.

    1983-10-01

    Since 1979, Ford Motor Company has been developing holographic interferometry to supplement more conventional test methods to measure vehicle component vibrations. An Apollo PHK-1 Double Pulse Holographic Laser System was employed to visualize a variety of complex vibration modes, primarily on current production and prototype powertrain components. Design improvements to reduce powertrain response to problem excitations have been deter-mined through pulsed laser holography, and have, in several cases, been put into production in Ford vehicles. Whole-field definition of vibration related deflections provide continuity of information missed by accelerometer/modal analysis techniaues. Certain opera-tional problems, common among pulsed ruby holographic lasers, have reauired ongoing hardware and electronics improvements to minimize system downtime. Real-time, time-averaged and stroboscopic C. W. laser holographic techniques are being developed at Ford to complement the double pulse capabilities and provide rapid identification of modal frequencies and nodal lines for analysis of powertrain structures. Methods for mounting and exciting powertrains to minimize rigid body motions are discussed. Work at Ford will continue toward development of C. W. holographic techniques to provide refined test methodology dedicated to noise and vibration diagnostics with particular emphasis on semi-automated methods for quantifying displacement and relative phase using high resolution digitized video and computers. Continued use of refined pulsed and CW laser holographic interferometry for the analysis of complex structure vibrations seems assured.

  7. Modal Analysis and Testing of Missile Systems

    DTIC Science & Technology

    1988-12-01

    TECHNICAL REPORT -Rb-ST-eS MODAL ANALY AND TESMG OF MISSU E SYSTEMS Lfl 0 N Larry C. Mixon John A4 Schaeffel , Jr. Peter L. Green ,I iLT Roque L...Include Stcurty Claz ficaDin) MODAL ANALYSIS AND TESTING OF MISSILE SYSTEMS 12. PERSONAL AUTHOR(S) Larry C. Mixon, John A. Schaeffel , Jr., Peter L. Green

  8. Online Multi-Modal Robust Non-Negative Dictionary Learning for Visual Tracking

    PubMed Central

    Zhang, Xiang; Guan, Naiyang; Tao, Dacheng; Qiu, Xiaogang; Luo, Zhigang

    2015-01-01

    Dictionary learning is a method of acquiring a collection of atoms for subsequent signal representation. Due to its excellent representation ability, dictionary learning has been widely applied in multimedia and computer vision. However, conventional dictionary learning algorithms fail to deal with multi-modal datasets. In this paper, we propose an online multi-modal robust non-negative dictionary learning (OMRNDL) algorithm to overcome this deficiency. Notably, OMRNDL casts visual tracking as a dictionary learning problem under the particle filter framework and captures the intrinsic knowledge about the target from multiple visual modalities, e.g., pixel intensity and texture information. To this end, OMRNDL adaptively learns an individual dictionary, i.e., template, for each modality from available frames, and then represents new particles over all the learned dictionaries by minimizing the fitting loss of data based on M-estimation. The resultant representation coefficient can be viewed as the common semantic representation of particles across multiple modalities, and can be utilized to track the target. OMRNDL incrementally learns the dictionary and the coefficient of each particle by using multiplicative update rules to respectively guarantee their non-negativity constraints. Experimental results on a popular challenging video benchmark validate the effectiveness of OMRNDL for visual tracking in both quantity and quality. PMID:25961715

  9. Online multi-modal robust non-negative dictionary learning for visual tracking.

    PubMed

    Zhang, Xiang; Guan, Naiyang; Tao, Dacheng; Qiu, Xiaogang; Luo, Zhigang

    2015-01-01

    Dictionary learning is a method of acquiring a collection of atoms for subsequent signal representation. Due to its excellent representation ability, dictionary learning has been widely applied in multimedia and computer vision. However, conventional dictionary learning algorithms fail to deal with multi-modal datasets. In this paper, we propose an online multi-modal robust non-negative dictionary learning (OMRNDL) algorithm to overcome this deficiency. Notably, OMRNDL casts visual tracking as a dictionary learning problem under the particle filter framework and captures the intrinsic knowledge about the target from multiple visual modalities, e.g., pixel intensity and texture information. To this end, OMRNDL adaptively learns an individual dictionary, i.e., template, for each modality from available frames, and then represents new particles over all the learned dictionaries by minimizing the fitting loss of data based on M-estimation. The resultant representation coefficient can be viewed as the common semantic representation of particles across multiple modalities, and can be utilized to track the target. OMRNDL incrementally learns the dictionary and the coefficient of each particle by using multiplicative update rules to respectively guarantee their non-negativity constraints. Experimental results on a popular challenging video benchmark validate the effectiveness of OMRNDL for visual tracking in both quantity and quality.

  10. Stroboscopic Interferometer for Measuring Mirror Vibrations

    NASA Technical Reports Server (NTRS)

    Stahl, H. Philip; Robers, Ted

    2005-01-01

    Stroboscopic interferometry is a technique for measuring the modes of vibration of mirrors that are lightweight and, therefore, unavoidably flexible. The technique was conceived especially for modal characterization of lightweight focusing mirror segments to be deployed in outer space; however, the technique can be applied to lightweight mirrors designed for use on Earth as well as the modal investigation of other optical and mechanical structures. To determine the modal structure of vibration of a mirror, it is necessary to excite the mirror by applying a force that varies periodically with time at a controllable frequency. The excitation can utilize sinusoidal, square, triangular, or even asynchronous waveforms. Because vibrational modes occur at specific resonant frequencies, it is necessary to perform synchronous measurements and sweep the frequency to locate the significant resonant modes. For a given mode it is possible to step the phase of data acquisition in order to capture the modal behavior over a single cycle of the resonant frequency. In order to measure interferometrically the vibrational response of the mirror at a given frequency, an interferometer must be suitably aligned with the mirror and adjustably phase-locked with the excitation signal. As in conventional stroboscopic photography, the basic idea in stroboscopic interferometry is to capture an image of the shape of a moving object (in this case, the vibrating mirror) at a specified instant of time in the vibration cycle. Adjusting the phase difference over a full cycle causes the interference fringes to vary over the full range of motion for the mode at the excitation frequency. The interference-fringe pattern is recorded as a function of the phase difference, and, from the resulting data, the surface shape of the mirror for the given mode is extracted. In addition to the interferometer and the mirror to be tested, the equipment needed for stroboscopic interferometry includes an arbitrary-function generator (that is, a signal generator), an oscilloscope, a trigger filter, and an advanced charge-coupled-device (CCD) camera. The optical components are positioned to form a pupil image of the mirror under test on the CCD chip, so that the interference pattern representative of the instantaneous mirror shape is imaged on the CCD chip.

  11. Cost analysis of two community-based HIV testing service modalities led by a Non-Governmental Organization in Cape Town, South Africa.

    PubMed

    Meehan, Sue-Ann; Beyers, Nulda; Burger, Ronelle

    2017-12-02

    In South Africa, the financing and sustainability of HIV services is a priority. Community-based HIV testing services (CB-HTS) play a vital role in diagnosis and linkage to HIV care for those least likely to utilise government health services. With insufficient estimates of the costs associated with CB-HTS provided by NGOs in South Africa, this cost analysis explored the cost to implement and provide services at two NGO-led CB-HTS modalities and calculated the costs associated with realizing key HIV outputs for each CB-HTS modality. The study took place in a peri-urban area where CB-HTS were provided from a stand-alone centre and mobile service. Using a service provider (NGO) perspective, all inputs were allocated by HTS modality with shared costs apportioned according to client volume or personnel time. We calculated the total cost of each HTS modality and the cost categories (personnel, capital and recurring goods/services) across each HTS modality. Costs were divided into seven pre-determined project components, used to examine cost drivers. HIV outputs were analysed for each HTS modality and the mean cost for each HIV output was calculated per HTS modality. The annual cost of the stand-alone and mobile modalities was $96,616 and $77,764 respectively, with personnel costs accounting for 54% of the total costs at the stand-alone. For project components, overheads and service provision made up the majority of the costs. The mean cost per person tested at stand-alone ($51) was higher than at the mobile ($25). Linkage to care cost at the stand-alone ($1039) was lower than the mobile ($2102). This study provides insight into the cost of an NGO led CB-HTS project providing HIV testing and linkage to care through two CB-HIV testing modalities. The study highlights; (1) the importance of including all applicable costs (including overheads) to ensure an accurate cost estimate that is representative of the full service implementation cost, (2) the direct link between test uptake and mean cost per person tested, and (3) the need for effective linkage to care strategies to increase linkage and thereby reduce the mean cost per person linked to HIV care.

  12. The increased use of computed tomography angiography and magnetic resonance angiography as the sole imaging modalities prior to infrainguinal bypass has had no effect on outcomes.

    PubMed

    Shue, Bing; Damle, Rachelle N; Flahive, Julie; Kalish, Jeffrey A; Stone, David H; Patel, Virendra I; Schanzer, Andres; Baril, Donald T

    2015-08-01

    Angiography remains the gold standard imaging modality before infrainguinal bypass. Computed tomography angiography (CTA) and magnetic resonance angiography (MRA) have emerged as noninvasive alternatives for preoperative imaging. We sought to examine contemporary trends in the utilization of CTA and MRA as isolated imaging modalities before infrainguinal bypass and to compare outcomes following infrainguinal bypass in patients who underwent CTA or MRA versus those who underwent conventional arteriography. Patients undergoing infrainguinal bypass within the Vascular Study Group of New England were identified (2003-2012). Patients were stratified by preoperative imaging modality: CTA/MRA alone or conventional angiography. Trends in utilization of these modalities were examined and demographics of these groups were compared. Primary end points included primary patency, secondary patency, and major adverse limb events (MALE) at 1 year as determined by Kaplan-Meier analysis. Multivariable Cox proportional hazards models were constructed to evaluate the effect of imaging modality on primary patency, secondary patency, and MALE after adjusting for confounders. In 3123 infrainguinal bypasses, CTA/MRA alone was used in 462 cases (15%) and angiography was used in 2661 cases (85%). Use of CTA/MRA alone increased over time, with 52 (11%) bypasses performed between 2003 and 2005, 189 (41%) bypasses performed between 2006 and 2009, and 221 (48%) bypasses performed between 2010 and 2012 (P < 0.001). Patients with CTA/MRA alone, compared with patients with angiography, more frequently underwent bypass for claudication (33% vs. 26%, P = 0.001) or acute limb ischemia (13% vs. 5%, P < 0.0001), more frequently had prosthetic conduits (39% vs. 30%, P = 0.001), and less frequently had tibial/pedal targets (32% vs. 40%, P = 0.002). After adjusting for these and other confounders, multivariable analysis demonstrated that the use of CTA/MRA alone was not associated with a significant difference in 1 year primary patency (hazard ratio [HR] 0.95, 95% confidence interval [CI] 0.78-1.16), secondary patency (HR 1.30, 95% CI 0.99-1.72), or MALE (HR 1.08, 95% CI 0.89-1.32). CTA and MRA are being increasingly used as the sole preoperative imaging modality before infrainguinal bypass. This shift in practice patterns appears to have no measurable effect on outcomes at 1 year. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Operational modal analysis of a high-rise multi-function building with dampers by a Bayesian approach

    NASA Astrophysics Data System (ADS)

    Ni, Yanchun; Lu, Xilin; Lu, Wensheng

    2017-03-01

    The field non-destructive vibration test plays an important role in the area of structural health monitoring. It assists in monitoring the health status and reducing the risk caused by the poor performance of structures. As the most economic field test among the various vibration tests, the ambient vibration test is the most popular and is widely used to assess the physical condition of a structure under operational service. Based on the ambient vibration data, modal identification can help provide significant previous study for model updating and damage detection during the service life of a structure. It has been proved that modal identification works well in the investigation of the dynamic performance of different kinds of structures. In this paper, the objective structure is a high-rise multi-function office building. The whole building is composed of seven three-story structural units. Each unit comprises one complete floor and two L shaped floors to form large spaces along the vertical direction. There are 56 viscous dampers installed in the building to improve the energy dissipation capacity. Due to the special feature of the structure, field vibration tests and further modal identification were performed to investigate its dynamic performance. Twenty-nine setups were designed to cover all the degrees of freedom of interest. About two years later, another field test was carried out to measure the building for 48 h to investigate the performance variance and the distribution of the modal parameters. A Fast Bayesian FFT method was employed to perform the modal identification. This Bayesian method not only provides the most probable values of the modal parameters but also assesses the associated posterior uncertainty analytically, which is especially relevant in field vibration tests arising due to measurement noise, sensor alignment error, modelling error, etc. A shaking table test was also implemented including cases with and without dampers, which assists in investigating the effect of dampers. The modal parameters obtained from different tests were investigated separately and then compared with each other.

  14. A Comparative Analysis of Polymerase Chain Reaction and Direct Fluorescent Antibody Test for Diagnosis of Genital Herpes.

    PubMed

    Patwardhan, Vrushali; Bhalla, Preena; Rawat, Deepti; Garg, Vijay Kumar; Sardana, Kabir; Sethi, Sumit

    2017-01-01

    To compare laboratory tests that can simultaneously detect and type herpes simplex virus (HSV) directly from the genital ulcer specimens in clinically suspected cases of genital herpes. A study was conducted over 10 months and 44 adult male and female patients clinically suspected with genital herpes were recruited. Genital ulcer swab specimens were subjected to glycoprotein-G gene-based conventional polymerase chain reaction (PCR) and commercially available direct fluorescent antibody (DFA) test and the results were compared. PCR for HSV was positive in 82% (36/44) cases. DFA was positive in 68.2% (30/44) cases. There was 100% agreement between HSV types detected by DFA and PCR. The strength of agreement between the results was better in primary genital herpes than recurrent cases. PCR was found to be better in the detection of HSV in recurrent genital herpes patients. It is a better modality, especially when genital herpes clinically presents with ulcerative or crusted lesions, and is also a cheaper alternative as compared to DFA.

  15. Ares I-X Flight Test Vehicle Modal Test

    NASA Technical Reports Server (NTRS)

    Buehrle, Ralph D.; Templeton, Justin D.; Reaves, Mercedes C.; Horta, Lucas G.; Gaspar, James L.; Bartolotta, Paul A.; Parks, Russel A.; Lazor, Daniel R.

    2010-01-01

    The first test flight of NASA's Ares I crew launch vehicle, called Ares I-X, was launched on October 28, 2009. Ares I-X used a 4-segment reusable solid rocket booster from the Space Shuttle heritage with mass simulators for the 5th segment, upper stage, crew module and launch abort system. Flight test data will provide important information on ascent loads, vehicle control, separation, and first stage reentry dynamics. As part of hardware verification, a series of modal tests were designed to verify the dynamic finite element model (FEM) used in loads assessments and flight control evaluations. Based on flight control system studies, the critical modes were the first three free-free bending mode pairs. Since a test of the free-free vehicle was not practical within project constraints, modal tests for several configurations during vehicle stacking were defined to calibrate the FEM. Test configurations included two partial stacks and the full Ares I-X flight test vehicle on the Mobile Launcher Platform. This report describes the test requirements, constraints, pre-test analysis, test execution and results for the Ares I-X flight test vehicle modal test on the Mobile Launcher Platform. Initial comparisons between pre-test predictions and test data are also presented.

  16. Bayesian evaluation of clinical diagnostic test characteristics of visual observations and remote monitoring to diagnose bovine respiratory disease in beef calves.

    PubMed

    White, Brad J; Goehl, Dan R; Amrine, David E; Booker, Calvin; Wildman, Brian; Perrett, Tye

    2016-04-01

    Accurate diagnosis of bovine respiratory disease (BRD) in beef cattle is a critical facet of therapeutic programs through promotion of prompt treatment of diseased calves in concert with judicious use of antimicrobials. Despite the known inaccuracies, visual observation (VO) of clinical signs is the conventional diagnostic modality for BRD diagnosis. Objective methods of remotely monitoring cattle wellness could improve diagnostic accuracy; however, little information exists describing the accuracy of this method compared to traditional techniques. The objective of this research is to employ Bayesian methodology to elicit diagnostic characteristics of conventional VO compared to remote early disease identification (REDI) to diagnose BRD. Data from previous literature on the accuracy of VO were combined with trial data consisting of direct comparison between VO and REDI for BRD in two populations. No true gold standard diagnostic test exists for BRD; therefore, estimates of diagnostic characteristics of each test were generated using Bayesian latent class analysis. Results indicate a 90.0% probability that the sensitivity of REDI (median 81.3%; 95% probability interval [PI]: 55.5, 95.8) was higher than VO sensitivity (64.5%; PI: 57.9, 70.8). The specificity of REDI (median 92.9%; PI: 88.2, 96.9) was also higher compared to VO (median 69.1%; PI: 66.3, 71.8). The differences in sensitivity and specificity resulted in REDI exhibiting higher positive and negative predictive values in both high (41.3%) and low (2.6%) prevalence situations. This research illustrates the potential of remote cattle monitoring to augment conventional methods of BRD diagnosis resulting in more accurate identification of diseased cattle. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Combined single photon emission computerized tomography and conventional computerized tomography: Clinical value for the shoulder surgeons?

    PubMed Central

    Hirschmann, Michael T.; Schmid, Rahel; Dhawan, Ranju; Skarvan, Jiri; Rasch, Helmut; Friederich, Niklaus F.; Emery, Roger

    2011-01-01

    With the cases described, we strive to introduce single photon emission computerized tomography in combination with conventional computer tomography (SPECT/CT) to shoulder surgeons, illustrate the possible clinical value it may offer as new diagnostic radiologic modality, and discuss its limitations. SPECT/CT may facilitate the establishment of diagnosis, process of decision making, and further treatment for complex shoulder pathologies. Some of these advantages were highlighted in cases that are frequently seen in most shoulder clinics. PMID:22058640

  18. A novel treatment modality in patients with premature ejaculation resistant to conventional methods: the neuromodulation of dorsal penile nerves by pulsed radiofrequency.

    PubMed

    Basal, Seref; Goktas, Serdar; Ergin, Atilla; Yildirim, Ibrahim; Atim, Abdulkadir; Tahmaz, Lutfi; Dayanc, Murat

    2010-01-01

    Premature ejaculation (PE) is the most common sexual problem experienced by men, and it affects 20%-30% of them. Pulsed radiofrequency (PRF) neuromodulation has been shown to be an effective treatment for a wide range of pain conditions. We used PRF to treat PE by desensitizing dorsal penile nerves in patients resistant to conventional treatments. Fifteen patients with a lifelong history of PE, defined as an intravaginal ejaculatory latency time (IELT) of <1 minute that occurred in more than 90% of acts of intercourse and was resistant to conventional treatments, were enrolled in this study. Patients with erectile dysfunction were excluded. The mean age of the patients was 39 +/- 9 years. Before and 3 weeks after the treatment, IELT and sexual satisfaction score (SSS; for patients and their partners) were obtained. The mean IELTs before and 3 weeks after procedure were 18.5 +/- 17.9 and 139.9 +/- 55.1 seconds, respectively. Side effects did not occur. Mean SSSs of patients before and after treatment were 1.3 +/- 0.3 and 4.6 +/- 0.5, and mean SSSs of partners before and after treatment were 1.3 +/- 0.4 and 4.4 +/- 0.5, respectively. In all cases, IELT and SSS were significantly increased (P < .05). None of the patients or their wives reported any treatment failure during the follow-up period. The mean follow-up time was 8.3 +/- 1.9 months. It is early to conclude that this new treatment modality might be used widely for the treatment of PE; however, because it is an innovative modality, placebo-controlled studies (eg, sham procedure), with larger numbers of patients and including assessment of penile sensitivity (eg, biothesiometry), are needed.

  19. Different treatment modalities for refractory vaginismus in western Saudi Arabia.

    PubMed

    Fageeh, Wafa M K

    2011-06-01

    Although vaginismus is a common sexual dysfunction in Saudi Arabia, there are limited data concerning the treatment modalities associated with patients with symptoms of vaginismus. This study is aimed to evaluate the presentation and different modalities of management in patients with severe refractory vaginismus in western Saudi Arabia. Successful penetrative sexual intercourse suggesting that common elements of the therapies used were successful. A retrospective study of patients presenting with severe refractory vaginismus treated in Jeddah, Saudi Arabia. The subjects were 15 women with third to fourth degree vaginismus who presented to King Abdulazziz University Hospital between January 1, 2008 and January 1, 2009. The mean age of the participants was 23 years. The mean duration of marriage before seeking medical advice was 12 months. Six patients had undergone conventional therapy successfully. The other six cases, four of which had a previous history of treatment failure, and two who were unresponsive to 4 months of conventional therapy were offered botulinum toxin type A. Five patients who received the Botox therapy had satisfactory intercourse on the same day of the treatment. One patient required a repeat injection after 2 months for recurrent vaginismus. Three of the 15 patients refused the treatment as they were already divorced and had only come in to exclude organic causes for their condition. Vaginismus is an overlooked topic in conservative societies such as Saudi Arabia. For most patients, not knowing who to confide in or where to turn to plays a major role in the under diagnosis of vaginismus. Conventional therapy proved effective in mild and moderate cases, while botulinum toxin has a more rapid effect and was thus more effective in severe cases. © 2011 International Society for Sexual Medicine.

  20. Applications of Electrical Impedance Tomography (EIT): A Short Review

    NASA Astrophysics Data System (ADS)

    Kanti Bera, Tushar

    2018-03-01

    Electrical Impedance Tomography (EIT) is a tomographic imaging method which solves an ill posed inverse problem using the boundary voltage-current data collected from the surface of the object under test. Though the spatial resolution is comparatively low compared to conventional tomographic imaging modalities, due to several advantages EIT has been studied for a number of applications such as medical imaging, material engineering, civil engineering, biotechnology, chemical engineering, MEMS and other fields of engineering and applied sciences. In this paper, the applications of EIT have been reviewed and presented as a short summary. The working principal, instrumentation and advantages are briefly discussed followed by a detail discussion on the applications of EIT technology in different areas of engineering, technology and applied sciences.

  1. Ambulatory hysteroscopy and its role in the management of abnormal uterine bleeding.

    PubMed

    Cooper, Natalie A M; Robinson, Lynne L L; Clark, T Justin

    2015-10-01

    Hysteroscopy is now an ambulatory procedure, having moved from a conventional day-case operating theatre environment to the outpatient clinic setting. Outpatient hysteroscopy can be used as a diagnostic test and as a therapeutic modality for women presenting with abnormal uterine bleeding. In many cases women can be diagnosed and treated efficiently during a single hospital appointment. This article reviews the development of ambulatory hysteroscopy and how it should optimally be performed and implemented. The contemporary role of this technology for investigating and treating women with abnormal uterine bleeding is then discussed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. MIND Demons for MR-to-CT Deformable Image Registration In Image-Guided Spine Surgery

    PubMed Central

    Reaungamornrat, S.; De Silva, T.; Uneri, A.; Wolinsky, J.-P.; Khanna, A. J.; Kleinszig, G.; Vogt, S.; Prince, J. L.; Siewerdsen, J. H.

    2016-01-01

    Purpose Localization of target anatomy and critical structures defined in preoperative MR images can be achieved by means of multi-modality deformable registration to intraoperative CT. We propose a symmetric diffeomorphic deformable registration algorithm incorporating a modality independent neighborhood descriptor (MIND) and a robust Huber metric for MR-to-CT registration. Method The method, called MIND Demons, solves for the deformation field between two images by optimizing an energy functional that incorporates both the forward and inverse deformations, smoothness on the velocity fields and the diffeomorphisms, a modality-insensitive similarity function suitable to multi-modality images, and constraints on geodesics in Lagrangian coordinates. Direct optimization (without relying on an exponential map of stationary velocity fields used in conventional diffeomorphic Demons) is carried out using a Gauss-Newton method for fast convergence. Registration performance and sensitivity to registration parameters were analyzed in simulation, in phantom experiments, and clinical studies emulating application in image-guided spine surgery, and results were compared to conventional mutual information (MI) free-form deformation (FFD), local MI (LMI) FFD, and normalized MI (NMI) Demons. Result The method yielded sub-voxel invertibility (0.006 mm) and nonsingular spatial Jacobians with capability to preserve local orientation and topology. It demonstrated improved registration accuracy in comparison to the reference methods, with mean target registration error (TRE) of 1.5 mm compared to 10.9, 2.3, and 4.6 mm for MI FFD, LMI FFD, and NMI Demons methods, respectively. Validation in clinical studies demonstrated realistic deformation with sub-voxel TRE in cases of cervical, thoracic, and lumbar spine. Conclusions A modality-independent deformable registration method has been developed to estimate a viscoelastic diffeomorphic map between preoperative MR and intraoperative CT. The method yields registration accuracy suitable to application in image-guided spine surgery across a broad range of anatomical sites and modes of deformation. PMID:27330239

  3. MIND Demons for MR-to-CT deformable image registration in image-guided spine surgery

    NASA Astrophysics Data System (ADS)

    Reaungamornrat, S.; De Silva, T.; Uneri, A.; Wolinsky, J.-P.; Khanna, A. J.; Kleinszig, G.; Vogt, S.; Prince, J. L.; Siewerdsen, J. H.

    2016-03-01

    Purpose: Localization of target anatomy and critical structures defined in preoperative MR images can be achieved by means of multi-modality deformable registration to intraoperative CT. We propose a symmetric diffeomorphic deformable registration algorithm incorporating a modality independent neighborhood descriptor (MIND) and a robust Huber metric for MR-to-CT registration. Method: The method, called MIND Demons, solves for the deformation field between two images by optimizing an energy functional that incorporates both the forward and inverse deformations, smoothness on the velocity fields and the diffeomorphisms, a modality-insensitive similarity function suitable to multi-modality images, and constraints on geodesics in Lagrangian coordinates. Direct optimization (without relying on an exponential map of stationary velocity fields used in conventional diffeomorphic Demons) is carried out using a Gauss-Newton method for fast convergence. Registration performance and sensitivity to registration parameters were analyzed in simulation, in phantom experiments, and clinical studies emulating application in image-guided spine surgery, and results were compared to conventional mutual information (MI) free-form deformation (FFD), local MI (LMI) FFD, and normalized MI (NMI) Demons. Result: The method yielded sub-voxel invertibility (0.006 mm) and nonsingular spatial Jacobians with capability to preserve local orientation and topology. It demonstrated improved registration accuracy in comparison to the reference methods, with mean target registration error (TRE) of 1.5 mm compared to 10.9, 2.3, and 4.6 mm for MI FFD, LMI FFD, and NMI Demons methods, respectively. Validation in clinical studies demonstrated realistic deformation with sub-voxel TRE in cases of cervical, thoracic, and lumbar spine. Conclusions: A modality-independent deformable registration method has been developed to estimate a viscoelastic diffeomorphic map between preoperative MR and intraoperative CT. The method yields registration accuracy suitable to application in image-guided spine surgery across a broad range of anatomical sites and modes of deformation.

  4. MIND Demons for MR-to-CT Deformable Image Registration In Image-Guided Spine Surgery.

    PubMed

    Reaungamornrat, S; De Silva, T; Uneri, A; Wolinsky, J-P; Khanna, A J; Kleinszig, G; Vogt, S; Prince, J L; Siewerdsen, J H

    2016-02-27

    Localization of target anatomy and critical structures defined in preoperative MR images can be achieved by means of multi-modality deformable registration to intraoperative CT. We propose a symmetric diffeomorphic deformable registration algorithm incorporating a modality independent neighborhood descriptor (MIND) and a robust Huber metric for MR-to-CT registration. The method, called MIND Demons, solves for the deformation field between two images by optimizing an energy functional that incorporates both the forward and inverse deformations, smoothness on the velocity fields and the diffeomorphisms, a modality-insensitive similarity function suitable to multi-modality images, and constraints on geodesics in Lagrangian coordinates. Direct optimization (without relying on an exponential map of stationary velocity fields used in conventional diffeomorphic Demons) is carried out using a Gauss-Newton method for fast convergence. Registration performance and sensitivity to registration parameters were analyzed in simulation, in phantom experiments, and clinical studies emulating application in image-guided spine surgery, and results were compared to conventional mutual information (MI) free-form deformation (FFD), local MI (LMI) FFD, and normalized MI (NMI) Demons. The method yielded sub-voxel invertibility (0.006 mm) and nonsingular spatial Jacobians with capability to preserve local orientation and topology. It demonstrated improved registration accuracy in comparison to the reference methods, with mean target registration error (TRE) of 1.5 mm compared to 10.9, 2.3, and 4.6 mm for MI FFD, LMI FFD, and NMI Demons methods, respectively. Validation in clinical studies demonstrated realistic deformation with sub-voxel TRE in cases of cervical, thoracic, and lumbar spine. A modality-independent deformable registration method has been developed to estimate a viscoelastic diffeomorphic map between preoperative MR and intraoperative CT. The method yields registration accuracy suitable to application in image-guided spine surgery across a broad range of anatomical sites and modes of deformation.

  5. Finite-Element Vibration Analysis and Modal Testing of Graphite Epoxy Tubes and Correlation Between the Data

    NASA Technical Reports Server (NTRS)

    Taleghani, Barmac K.; Pappa, Richard S.

    1996-01-01

    Structural materials in the form of graphite epoxy composites with embedded rubber layers are being used to reduce vibrations in rocket motor tubes. Four filament-wound, graphite epoxy tubes were studied to evaluate the effects of the rubber layer on the modal parameters (natural vibration frequencies, damping, and mode shapes). Tube 1 contained six alternating layers of 30-degree helical wraps and 90-degree hoop wraps. Tube 2 was identical to tube 1 with the addition of an embedded 0.030-inch-thick rubber layer. Tubes 3 and 4 were identical to tubes 1 and 2, respectively, with the addition of a Textron Kelpoxy elastomer. This report compares experimental modal parameters obtained by impact testing with analytical modal parameters obtained by NASTRAN finite-element analysis. Four test modes of tube 1 and five test modes of tube 3 correlate highly with corresponding analytical predictions. Unsatisfactory correlation of test and analysis results occurred for tubes 2 and 4 and these comparisons are not shown. Work is underway to improve the analytical models of these tubes. Test results clearly show that the embedded rubber layers significantly increase structural modal damping as well as decrease natural vibration frequencies.

  6. Guide for diagnosis and treatment of hepatocellular carcinoma

    PubMed Central

    Attwa, Magdy Hamed; El-Etreby, Shahira Aly

    2015-01-01

    Hepatocellular carcinoma (HCC) is ranked as the 5th common type of cancer worldwide and is considered as the 3rd common reason for cancer-related deaths. HCC often occurs on top of a cirrhotic liver. The prognosis is determined by several factors; tumour extension, alpha-fetoprotein (AFP) concentration, histologic subtype of the tumour, degree of liver dysfunction, and the patient’s performance status. HCC prognosis is strongly correlated with diagnostic delay. To date, no ideal screening modality has been developed. Analysis of recent studies showed that AFP assessment lacks adequate sensitivity and specificity for effective surveillance and diagnosis. Many tumour markers have been tested in clinical trials without progressing to routine use in clinical practice. Thus, surveillance is still based on ultrasound (US) examination every 6 mo. Imaging studies for diagnosis of HCC can fall into one of two main categories: routine non-invasive studies such as US, computed tomography (CT), and magnetic resonance imaging, and more specialized invasive techniques including CT during hepatic arteriography and CT arterial portography in addition to the conventional hepatic angiography. This article provides an overview and spotlight on the different diagnostic modalities and treatment options of HCC. PMID:26140083

  7. Time domain modal identification/estimation of the mini-mast testbed

    NASA Technical Reports Server (NTRS)

    Roemer, Michael J.; Mook, D. Joseph

    1991-01-01

    The Mini-Mast is a 20 meter long 3-dimensional, deployable/retractable truss structure designed to imitate future trusses in space. Presented here are results from a robust (with respect to measurement noise sensitivity), time domain, modal identification technique for identifying the modal properties of the Mini-Mast structure even in the face of noisy environments. Three testing/analysis procedures are considered: sinusoidal excitation near resonant frequencies of the Mini-Mast, frequency response function averaging of several modal tests, and random input excitation with a free response period.

  8. Diode Laser Assisted Excision and Low Level Laser Therapy in the Management of Mucus Extravasation Cysts: A Case Series

    PubMed Central

    Ahad, Abdul; Tandon, Shruti; Lamba, Arundeep Kaur; Faraz, Farrukh; Anand, Parimal; Aleem, Abdul

    2017-01-01

    Introduction: Mucus extravasation cyst is a commonly occurring lesion in oral cavity that may result from traumatic severance of a salivary gland duct with subsequent extravasation of mucus into fibrous connective tissue. After a conventional excision or marsupialization, recurrence is not uncommon. Diode laser offers an effective modality for management of such lesions. Case Reports: Four patients were referred with painless fluctuant swellings on labial and buccal mucosa. After recording history and clinical examination, provisional diagnosis of mucocele was made. All the lesions were excised with a diode laser and biopsy was performed. Surgical wounds were treated with low-level laser therapy (LLLT). Results: Uneventful healing was observed in all 4 cases. Significant reduction in postoperative discomfort was recorded after application of LLLT. Histopathological findings were suggestive of mucus extravasation cysts. Conclusion: Diode laser appears to be a good alternative to conventional modalities for the management of mucus extravasation cysts. PMID:29123637

  9. Diode Laser Assisted Excision and Low Level Laser Therapy in the Management of Mucus Extravasation Cysts: A Case Series.

    PubMed

    Ahad, Abdul; Tandon, Shruti; Lamba, Arundeep Kaur; Faraz, Farrukh; Anand, Parimal; Aleem, Abdul

    2017-01-01

    Introduction: Mucus extravasation cyst is a commonly occurring lesion in oral cavity that may result from traumatic severance of a salivary gland duct with subsequent extravasation of mucus into fibrous connective tissue. After a conventional excision or marsupialization, recurrence is not uncommon. Diode laser offers an effective modality for management of such lesions. Case Reports: Four patients were referred with painless fluctuant swellings on labial and buccal mucosa. After recording history and clinical examination, provisional diagnosis of mucocele was made. All the lesions were excised with a diode laser and biopsy was performed. Surgical wounds were treated with low-level laser therapy (LLLT). Results: Uneventful healing was observed in all 4 cases. Significant reduction in postoperative discomfort was recorded after application of LLLT. Histopathological findings were suggestive of mucus extravasation cysts. Conclusion: Diode laser appears to be a good alternative to conventional modalities for the management of mucus extravasation cysts.

  10. Galileo spacecraft modal test and evaluation of testing techniques

    NASA Technical Reports Server (NTRS)

    Chen, J.-C.

    1984-01-01

    The structural configuration, modal test requirements and pre-test activities involved in modeling the expected dynamic environment and responses of the Galileo spacecraft are discussed. The probe will be Shuttle-launched in 1986 and will gather data on the Jupiter system. Loads analysis for the 5300 lb spacecraft were performed with the NASTRAN code, and covered 10,000 static degrees of freedom and 1600 mass degrees of freedom. A modal analysis will be used to verify the predictions for natural frequencies, mode shapes, orthogonality checks, residual mass, modal damping and forces, and generalized forces. Verification of the validity of considering only 70 natural modes in the numerical simulation is being performed by examining the forcing functions of the analysis. The analysis led to requirements that 162 channels of accelerometer data and 118 channels of strain gage data be recorded during shaker tests to reveal areas where design changes will be needed to eliminate vibration peaks.

  11. The Various Applications of 3D Printing in Cardiovascular Diseases.

    PubMed

    El Sabbagh, Abdallah; Eleid, Mackram F; Al-Hijji, Mohammed; Anavekar, Nandan S; Holmes, David R; Nkomo, Vuyisile T; Oderich, Gustavo S; Cassivi, Stephen D; Said, Sameh M; Rihal, Charanjit S; Matsumoto, Jane M; Foley, Thomas A

    2018-05-10

    To highlight the various applications of 3D printing in cardiovascular disease and discuss its limitations and future direction. Use of handheld 3D printed models of cardiovascular structures has emerged as a facile modality in procedural and surgical planning as well as education and communication. Three-dimensional (3D) printing is a novel imaging modality which involves creating patient-specific models of cardiovascular structures. As percutaneous and surgical therapies evolve, spatial recognition of complex cardiovascular anatomic relationships by cardiologists and cardiovascular surgeons is imperative. Handheld 3D printed models of cardiovascular structures provide a facile and intuitive road map for procedural and surgical planning, complementing conventional imaging modalities. Moreover, 3D printed models are efficacious educational and communication tools. This review highlights the various applications of 3D printing in cardiovascular diseases and discusses its limitations and future directions.

  12. Imaging of gout: an overview.

    PubMed

    Dalbeth, Nicola; Doyle, Anthony J

    2012-12-01

    The diverse clinical states and sites of pathology in gout provide challenges when considering the features apparent on imaging. Ideally, an imaging modality should capture all aspects of disease including monosodium urate crystal deposition, acute inflammation, tophus, tissue remodelling and complications of disease. The modalities used in gout include conventional radiography, ultrasonography, magnetic resonance imaging, computed tomography and dual-energy computed tomography. This review discusses the role of each of these imaging modalities in gout, focussing on the imaging characteristics, role in gout diagnosis and role for disease monitoring. Ultrasonography and dual-energy computed tomography are particularly promising methods for both non-invasive diagnosis and monitoring of disease. The observation that ultrasonographic appearances of monosodium urate crystal deposition can be observed in patients with hyperuricaemia but no other clinical features of gout raises important questions about disease definitions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Conventional versus robot-assisted laparoscopic Nissen fundoplication: a comparison of postoperative acid reflux parameters.

    PubMed

    Frazzoni, Marzio; Conigliaro, Rita; Colli, Giovanni; Melotti, Gianluigi

    2012-06-01

    Laparoscopic Nissen fundoplication (LNF) is a technically demanding surgical procedure designed to cure gastroesophageal reflux disease (GERD). It represents an alternative to life-long medical therapy and the only recommended treatment modality to overcome refractoriness to proton pump inhibitor (PPI) therapy. The recent development of robotic systems prompted evaluation of their use in antireflux surgery. Between 1997 and 2000, in a PPI-responsive series we found postoperative normalization of esophageal acid exposure time (EAET) in most but not all cases. Between 2007 and 2009, in a PPI-refractory series we found postoperative normalization of EAET in all cases. We decided to analyze retrospectively our prospectively collected data to evaluate whether differences other than the conventional or robot-assisted technique could justify postoperative differences in acid reflux parameters. Baseline demographic, endoscopic, and manometric parameters were compared between the two series of patients, as well as postoperative manometric and acid reflux parameters. There were no significant differences in the baseline demographic, endoscopic, and manometric characteristics between the two groups of patients. The median lower esophageal sphincter tone increased significantly, and the median EAET decreased significantly after conventional as well as after robot-assisted LNF. The median postoperative EAET was significantly lower in the robot-assisted (0.2%) than in the conventional LNF group (1%; P = 0.001). Abnormal EAET values were found in 6 of 44 (14%) and in 0 of 44 cases after conventional and robot-assisted LNF, respectively (P = 0.026). Robot-assisted LNF provided a significant gain in postoperative acid reflux parameters compared with the conventional technique. In a challenging clinical setting, such as PPI-refractoriness, in which the efficacy of endoscopic or pharmacological treatment modalities is only moderate, even a small therapeutic gain can be clinically relevant. In centers where robot-assisted LNF is available, it should be preferred to conventional LNF in PPI-refractory GERD.

  14. Identification of Nasal Bone Fractures on Conventional Radiography and Facial CT: Comparison of the Diagnostic Accuracy in Different Imaging Modalities and Analysis of Interobserver Reliability

    PubMed Central

    Baek, Hye Jin; Kim, Dong Wook; Ryu, Ji Hwa; Lee, Yoo Jin

    2013-01-01

    Background There has been no study to compare the diagnostic accuracy of an experienced radiologist with a trainee in nasal bone fracture. Objectives To compare the diagnostic accuracy between conventional radiography and computed tomography (CT) for the identification of nasal bone fractures and to evaluate the interobserver reliability between a staff radiologist and a trainee. Patients and Methods A total of 108 patients who underwent conventional radiography and CT after acute nasal trauma were included in this retrospective study. Two readers, a staff radiologist and a second-year resident, independently assessed the results of the imaging studies. Results Of the 108 patients, the presence of a nasal bone fracture was confirmed in 88 (81.5%) patients. The number of non-depressed fractures was higher than the number of depressed fractures. In nine (10.2%) patients, nasal bone fractures were only identified on conventional radiography, including three depressed and six non-depressed fractures. CT was more accurate as compared to conventional radiography for the identification of nasal bone fractures as determined by both readers (P <0.05), all diagnostic indices of an experienced radiologist were similar to or higher than those of a trainee, and κ statistics showed moderate agreement between the two diagnostic tools for both readers. There was no statistical difference in the assessment of interobserver reliability for both imaging modalities in the identification of nasal bone fractures. Conclusion For the identification of nasal bone fractures, CT was significantly superior to conventional radiography. Although a staff radiologist showed better values in the identification of nasal bone fracture and differentiation between depressed and non-depressed fractures than a trainee, there was no statistically significant difference in the interpretation of conventional radiography and CT between a radiologist and a trainee. PMID:24348599

  15. Quantifying and managing uncertainty in operational modal analysis

    NASA Astrophysics Data System (ADS)

    Au, Siu-Kui; Brownjohn, James M. W.; Mottershead, John E.

    2018-03-01

    Operational modal analysis aims at identifying the modal properties (natural frequency, damping, etc.) of a structure using only the (output) vibration response measured under ambient conditions. Highly economical and feasible, it is becoming a common practice in full-scale vibration testing. In the absence of (input) loading information, however, the modal properties have significantly higher uncertainty than their counterparts identified from free or forced vibration (known input) tests. Mastering the relationship between identification uncertainty and test configuration is of great interest to both scientists and engineers, e.g., for achievable precision limits and test planning/budgeting. Addressing this challenge beyond the current state-of-the-art that are mostly concerned with identification algorithms, this work obtains closed form analytical expressions for the identification uncertainty (variance) of modal parameters that fundamentally explains the effect of test configuration. Collectively referred as 'uncertainty laws', these expressions are asymptotically correct for well-separated modes, small damping and long data; and are applicable under non-asymptotic situations. They provide a scientific basis for planning and standardization of ambient vibration tests, where factors such as channel noise, sensor number and location can be quantitatively accounted for. The work is reported comprehensively with verification through synthetic and experimental data (laboratory and field), scientific implications and practical guidelines for planning ambient vibration tests.

  16. Dynamic (Vibration) Testing: Design-Certification of Aerospace System

    NASA Technical Reports Server (NTRS)

    Aggarwal, Pravin K.

    2010-01-01

    Various types of dynamic testing of structures for certification purposes are described, including vibration, shock and acoustic testing. Modal testing is discussed as it frequently complements dynamic testing and is part of the structural verification/validation process leading up to design certification. Examples of dynamic and modal testing are presented as well as the common practices, procedures and standards employed.

  17. Comparison of tactile, auditory, and visual modality for brain-computer interface use: a case study with a patient in the locked-in state.

    PubMed

    Kaufmann, Tobias; Holz, Elisa M; Kübler, Andrea

    2013-01-01

    This paper describes a case study with a patient in the classic locked-in state, who currently has no means of independent communication. Following a user-centered approach, we investigated event-related potentials (ERP) elicited in different modalities for use in brain-computer interface (BCI) systems. Such systems could provide her with an alternative communication channel. To investigate the most viable modality for achieving BCI based communication, classic oddball paradigms (1 rare and 1 frequent stimulus, ratio 1:5) in the visual, auditory and tactile modality were conducted (2 runs per modality). Classifiers were built on one run and tested offline on another run (and vice versa). In these paradigms, the tactile modality was clearly superior to other modalities, displaying high offline accuracy even when classification was performed on single trials only. Consequently, we tested the tactile paradigm online and the patient successfully selected targets without any error. Furthermore, we investigated use of the visual or tactile modality for different BCI systems with more than two selection options. In the visual modality, several BCI paradigms were tested offline. Neither matrix-based nor so-called gaze-independent paradigms constituted a means of control. These results may thus question the gaze-independence of current gaze-independent approaches to BCI. A tactile four-choice BCI resulted in high offline classification accuracies. Yet, online use raised various issues. Although performance was clearly above chance, practical daily life use appeared unlikely when compared to other communication approaches (e.g., partner scanning). Our results emphasize the need for user-centered design in BCI development including identification of the best stimulus modality for a particular user. Finally, the paper discusses feasibility of EEG-based BCI systems for patients in classic locked-in state and compares BCI to other AT solutions that we also tested during the study.

  18. A break-even analysis of delivering a memory clinic by videoconferencing.

    PubMed

    Comans, Tracy A; Martin-Khan, Melinda; Gray, Leonard C; Scuffham, Paul A

    2013-10-01

    We analysed the costs of two kinds of dementia clinic. In the conventional clinic, held in a rural area, the specialist travels to the clinic from the city. In the videoconferencing clinic, patients are also seen in a rural area, but the specialist conducts the assessment by video from the city. The fixed costs common to both modalities, such as clinic infrastructure, were ignored. The total fixed cost of a monthly conventional clinic was $522 and the total fixed cost of a monthly videoconferencing clinic was $881. The additional variable cost of the specialist travelling to the conventional clinic was $2.62 per minute of the specialist's travelling time. The break-even point at which the cost of the two modalities is the same was just over two hours (138 min round trip). A sensitivity analysis showed that the break-even point was not particularly sensitive to changes in staff wages, but slightly more sensitive to the non labour costs of videoconferencing. Air travel is not an efficient alternative to travel by car. Reducing the number of clinics to six per year results in a much higher cost of running the videoconferencing service compared to the conventional service. Videoconferencing for the purpose of diagnosing dementia is both a reliable and cost effective method of health service provision when a specialist is required to drive for more than about two hours (round trip) to provide a memory disorder clinic service.

  19. Overview of multi-input frequency domain modal testing methods with an emphasis on sine testing

    NASA Technical Reports Server (NTRS)

    Rost, Robert W.; Brown, David L.

    1988-01-01

    An overview of the current state of the art multiple-input, multiple-output modal testing technology is discussed. A very brief review of the current time domain methods is given. A detailed review of frequency and spatial domain methods is presented with an emphasis on sine testing.

  20. TACT: A Set of MSC/PATRAN- and MSC/NASTRAN- based Modal Correlation Tools

    NASA Technical Reports Server (NTRS)

    Marlowe, Jill M.; Dixon, Genevieve D.

    1998-01-01

    This paper describes the functionality and demonstrates the utility of the Test Analysis Correlation Tools (TACT), a suite of MSC/PATRAN Command Language (PCL) tools which automate the process of correlating finite element models to modal survey test data. The initial release of TACT provides a basic yet complete set of tools for performing correlation totally inside the PATRAN/NASTRAN environment. Features include a step-by-step menu structure, pre-test accelerometer set evaluation and selection, analysis and test result export/import in Universal File Format, calculation of frequency percent difference and cross-orthogonality correlation results using NASTRAN, creation and manipulation of mode pairs, and five different ways of viewing synchronized animations of analysis and test modal results. For the PATRAN-based analyst, TACT eliminates the repetitive, time-consuming and error-prone steps associated with transferring finite element data to a third-party modal correlation package, which allows the analyst to spend more time on the more challenging task of model updating. The usefulness of this software is presented using a case history, the correlation for a NASA Langley Research Center (LaRC) low aspect ratio research wind tunnel model. To demonstrate the improvements that TACT offers the MSC/PATRAN- and MSC/DIASTRAN- based structural analysis community, a comparison of the modal correlation process using TACT within PATRAN versus external third-party modal correlation packages is presented.

  1. Efficacy of do-it-yourself whitening as compared to conventional tooth whitening modalities: an in vitro study.

    PubMed

    Kwon, S R; Meharry, M; Oyoyo, U; Li, Y

    2015-01-01

    To evaluate the efficacy of do-it-yourself (DIY) whitening as compared to conventional tooth whitening modalities using different shade assessment tools. Extracted human molars (120) were randomly distributed to six groups (n=20). Whitening was performed according to manufacturer's directions for over-the-counter, dentist-dispensed for home use, and in-office whitening. DIY whitening consisted of a strawberry and baking soda mix. Additionally, negative and positive controls were used. Two evaluators used the Vita Classical (VC) and Vita Bleachedguide 3D-Master with interpolated numbers (BGi) for visual assessment at baseline and one-week, one-month, and three-month postwhitening. Instrumental measurements were performed with a spectrophotometer. Kruskal-Wallis procedure was used to assess color changes among groups and intraclass correlation (ICC) to evaluate agreement between evaluators. DIY exhibited lower color change (ΔSGUVC, ΔSGUBGi, ΔE*, where SGU = shade guide unit and E = overall color change) compared to other whitening groups at all time points (p<0.05). ICC demonstrated very good agreement between evaluators with VC and BGi at each time point. Both shade guides were related with each other and strongly related to instrumental measurements (p<0.05). DIY whitening was the least effective whitening modality. Both VC and BGi are related with each other and have good correlation with instrumental measurements.

  2. Simulation and Optimization of an Astrophotonic Reformatter

    NASA Astrophysics Data System (ADS)

    Anagnos, Th; Harris, R. J.; Corrigan, M. K.; Reeves, A. P.; Townson, M. J.; MacLachlan, D. G.; Thomson, R. R.; Morris, T. J.; Schwab, C.; Quirrenbach, A.

    2018-05-01

    Image slicing is a powerful technique in astronomy. It allows the instrument designer to reduce the slit width of the spectrograph, increasing spectral resolving power whilst retaining throughput. Conventionally this is done using bulk optics, such as mirrors and prisms, however more recently astrophotonic components known as PLs and photonic reformatters have also been used. These devices reformat the MM input light from a telescope into SM outputs, which can then be re-arranged to suit the spectrograph. The PD is one such device, designed to reduce the dependence of spectrograph size on telescope aperture and eliminate modal noise. We simulate the PD, by optimising the throughput and geometrical design using Soapy and BeamProp. The simulated device shows a transmission between 8 and 20 %, depending upon the type of AO correction applied, matching the experimental results well. We also investigate our idealised model of the PD and show that the barycentre of the slit varies only slightly with time, meaning that the modal noise contribution is very low when compared to conventional fibre systems. We further optimise our model device for both higher throughput and reduced modal noise. This device improves throughput by 6.4 % and reduces the movement of the slit output by 50%, further improving stability. This shows the importance of properly simulating such devices, including atmospheric effects. Our work complements recent work in the field and is essential for optimising future photonic reformatters.

  3. Comparative effect of atypical and conventional antipsychotic drugs on neurocognition in first-episode psychosis: a randomized, double-blind trial of olanzapine versus low doses of haloperidol.

    PubMed

    Keefe, Richard S E; Seidman, Larry J; Christensen, Bruce K; Hamer, Robert M; Sharma, Tonmoy; Sitskoorn, Margriet M; Lewine, Richard R J; Yurgelun-Todd, Deborah A; Gur, Ruben C; Tohen, Mauricio; Tollefson, Gary D; Sanger, Todd M; Lieberman, Jeffrey A

    2004-06-01

    The effect of antipsychotic medication on neurocognitive function remains controversial, especially since most previous work has compared the effects of novel antipsychotic medications with those of high doses of conventional medications. This study compares the neurocognitive effects of olanzapine and low doses of haloperidol in patients with first-episode psychosis. Patients with a first episode of schizophrenia, schizoaffective disorder, or schizophreniform disorder (N=167) were randomly assigned to double-blind treatment with olanzapine (mean modal dose= 9.63 mg/day) or haloperidol (mean modal dose=4.60 mg/day) for the 12-week acute phase of a 2-year study. The patients were assessed with a battery of neurocognitive tests at baseline and 12 weeks after beginning treatment. An unweighted neurocognitive composite score, composed of measures of verbal fluency, motor functions, working memory, verbal memory, and vigilance, improved significantly with both haloperidol and olanzapine treatment (effect sizes of 0.20 and 0.36, respectively, no significant difference between groups). A weighted composite score developed from a principal-component analysis of the same measures improved to a significantly greater degree with olanzapine, compared with haloperidol. Anticholinergic use, extrapyramidal symptoms, and estimated IQ had little effect on the statistical differentiation of the medications, although duration of illness had a modest effect. The correlations of cognitive improvement with changes in clinical characteristics and with side effects of treatment were significant for patients who received haloperidol but not for patients who received olanzapine. Olanzapine has a beneficial effect on neurocognitive function in patients with a first episode of psychosis. However, in a comparison of the effects of olanzapine and low doses of haloperidol, the difference in benefit is small.

  4. Exergaming boxing versus heavy-bag boxing: are these equipotent for individuals with spinal cord injury?

    PubMed

    Mat Rosly, Maziah; Mat Rosly, Hadi; Hasnan, Nazirah; Davis, Glen M; Husain, Ruby

    2017-08-01

    Current strategies for increased physical activity and exercise in individuals with spinal cord injury (SCI) face many challenges with regards to maintaining their continuity of participation. Barriers cited often include problems with accessing facilities, mundane, monotonous or boring exercises and expensive equipment that is often not adapted for wheelchair users. To compare the physiological responses and user preferences between conventional heavy-bag boxing against a novel form of video game boxing, known as exergaming boxing. Cross-sectional study. Exercise laboratory setting in a university medical center. Seventeen participants with SCI were recruited, of which sixteen were male and only one female. Their mean age was 35.6±10.2 years. All of them performed a 15-minute physical exercise session of exergaming and heavy-bag boxing in a sitting position. The study assessed physiological responses in terms of oxygen consumption, metabolic equivalent (MET) and energy expenditure between exergaming and heavy-bag boxing derived from open-circuit spirometry. Participants also rated their perceived exertion using Borg's category-ratio ratings of perceived exertion. Both exergaming (MET: 4.3±1.0) and heavy-bag boxing (MET: 4.4±1.0) achieved moderate exercise intensities in these participants with SCI. Paired t-test revealed no significant differences (P>0.05, Cohen's d: 0.02-0.49) in the physiological or perceived exertional responses between the two modalities of boxing. Post session user survey reported all the participants found exergaming boxing more enjoyable. Exergaming boxing, was able to produce equipotent physiological responses as conventional heavy-bag boxing. The intensity of both exercise modalities achieved recommended intensities for health and fitness benefits. Exergaming boxing have the potential to provide an enjoyable, self-competitive environment for moderate-vigorous exercise even at the comfort of their homes.

  5. A cognitive approach for design of a multimedia informed consent video and website in pediatric research.

    PubMed

    Antal, Holly; Bunnell, H Timothy; McCahan, Suzanne M; Pennington, Chris; Wysocki, Tim; Blake, Kathryn V

    2017-02-01

    Poor participant comprehension of research procedures following the conventional face-to-face consent process for biomedical research is common. We describe the development of a multimedia informed consent video and website that incorporates cognitive strategies to enhance comprehension of study related material directed to parents and adolescents. A multidisciplinary team was assembled for development of the video and website that included human subjects professionals; psychologist researchers; institutional video and web developers; bioinformaticians and programmers; and parent and adolescent stakeholders. Five learning strategies that included Sensory-Modality view, Coherence, Signaling, Redundancy, and Personalization were integrated into a 15-min video and website material that describes a clinical research trial. A diverse team collaborated extensively over 15months to design and build a multimedia platform for obtaining parental permission and adolescent assent for participant in as asthma clinical trial. Examples of the learning principles included, having a narrator describe what was being viewed on the video (sensory-modality); eliminating unnecessary text and graphics (coherence); having the initial portion of the video explain the sections of the video to be viewed (signaling); avoiding simultaneous presentation of text and graphics (redundancy); and having a consistent narrator throughout the video (personalization). Existing conventional and multimedia processes for obtaining research informed consent have not actively incorporated basic principles of human cognition and learning in the design and implementation of these processes. The present paper illustrates how this can be achieved, setting the stage for rigorous evaluation of potential benefits such as improved comprehension, satisfaction with the consent process, and completion of research objectives. New consent strategies that have an integrated cognitive approach need to be developed and tested in controlled trials. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Key informant interviews test plan : model deployment of a regional, multi-modal 511 traveler information system

    DOT National Transportation Integrated Search

    2004-01-28

    This document presents the detailed plan to conduct the Key Informants Interviews Test, one of several test activities to be conducted as part of the national evaluation of the regional, multi-modal 511 Traveler Information System Model Deployment. T...

  7. Finite-element analysis and modal testing of a rotating wind turbine

    NASA Astrophysics Data System (ADS)

    Carne, T. G.; Lobitz, D. W.; Nord, A. R.; Watson, R. A.

    1982-10-01

    A finite element procedure, which includes geometric stiffening, and centrifugal and Coriolis terms resulting from the use of a rotating coordinate system, was developed to compute the mode shapes and frequencies of rotating structures. Special applications of this capability was made to Darrieus, vertical axis wind turbines. In a parallel development effort, a technique for the modal testing of a rotating vertical axis wind turbine is established to measure modal parameters directly. Results from the predictive and experimental techniques for the modal frequencies and mode shapes are compared over a wide range of rotational speeds.

  8. Finite element analysis and modal testing of a rotating wind turbine

    NASA Astrophysics Data System (ADS)

    Carne, T. G.; Lobitz, D. W.; Nord, A. R.; Watson, R. A.

    A finite element procedure, which includes geometric stiffening, and centrifugal and Coriolis terms resulting from the use of a rotating coordinate system, has been developed to compute the mode shapes and frequencies of rotating structures. Special application of this capability has been made to Darrieus, vertical axis wind turbines. In a parallel development effort, a technique for the modal testing of a rotating vertical axis wind turbine has been established to measure modal parameters directly. Results from the predictive and experimental techniques for the modal frequencies and mode shapes are compared over a wide range of rotational speeds.

  9. Effect of stimulus type and temperature on EEG reactivity in cardiac arrest.

    PubMed

    Fantaneanu, Tadeu A; Tolchin, Benjamin; Alvarez, Vincent; Friolet, Raymond; Avery, Kathleen; Scirica, Benjamin M; O'Brien, Molly; Henderson, Galen V; Lee, Jong Woo

    2016-11-01

    Electroencephalogram (EEG) background reactivity is a reliable outcome predictor in cardiac arrest patients post therapeutic hypothermia. However, there is no consensus on modality testing and prior studies reveal only fair to moderate agreement rates. The aim of this study was to explore different stimulus modalities and report interrater agreements. We studied a multicenter, prospectively collected cohort of cardiac arrest patients who underwent therapeutic hypothermia between September 2014 and December 2015. We identified patients with reactivity data and evaluated interrater agreements of different stimulus modalities tested in hypothermia and normothermia. Of the 60 patients studied, agreement rates were moderate to substantial during hypothermia and fair to moderate during normothermia. Bilateral nipple pressure is more sensitive (80%) when compared to other modalities in eliciting a reactive background in hypothermia. Auditory, nasal tickle, nailbed pressure and nipple pressure reactivity were associated with good outcomes in both hypothermia and normothermia. EEG reactivity varies depending on the stimulus testing modality as well as the temperature during which stimulation is performed, with nipple pressure emerging as the most sensitive during hypothermia for reactivity and outcome determination. This highlights the importance of multiple stimulus testing modalities in EEG reactivity determination to reduce false negatives and optimize prognostication. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  10. 40 CFR 1048.505 - How do I test engines using steady-state duty cycles, including ramped-modal testing?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-state duty cycles, including ramped-modal testing? 1048.505 Section 1048.505 Protection of Environment... SPARK-IGNITION ENGINES Test Procedures § 1048.505 How do I test engines using steady-state duty cycles... some cases, we allow you to choose the appropriate steady-state duty cycle for an engine. In these...

  11. Free-decay time-domain modal identification for large space structures

    NASA Technical Reports Server (NTRS)

    Kim, Hyoung M.; Vanhorn, David A.; Doiron, Harold H.

    1992-01-01

    Concept definition studies for the Modal Identification Experiment (MIE), a proposed space flight experiment for the Space Station Freedom (SSF), have demonstrated advantages and compatibility of free-decay time-domain modal identification techniques with the on-orbit operational constraints of large space structures. Since practical experience with modal identification using actual free-decay responses of large space structures is very limited, several numerical and test data reduction studies were conducted. Major issues and solutions were addressed, including closely-spaced modes, wide frequency range of interest, data acquisition errors, sampling delay, excitation limitations, nonlinearities, and unknown disturbances during free-decay data acquisition. The data processing strategies developed in these studies were applied to numerical simulations of the MIE, test data from a deployable truss, and launch vehicle flight data. Results of these studies indicate free-decay time-domain modal identification methods can provide accurate modal parameters necessary to characterize the structural dynamics of large space structures.

  12. Use of Video and Audio Texts in EFL Listening Test

    ERIC Educational Resources Information Center

    Basal, Ahmet; Gülözer, Kaine; Demir, Ibrahim

    2015-01-01

    The study aims to discover whether audio or video modality in a listening test is more beneficial to test takers. In this study, the posttest-only control group design was utilized and quantitative data were collected in order to measure participant performances concerning two types of modality (audio or video) in a listening test. The…

  13. Multiple Modes in Corporate Learning: Propelling Business IQ with Formal, Informal and Social Learning

    ERIC Educational Resources Information Center

    Ambrose, John; Ogilvie, Julie

    2010-01-01

    Recognizing that the shifting corporate environment is placing ever greater stresses on learning organizations, this paper reports how companies are increasingly offering employees a wide choice of learning options beyond conventional classroom training, including online, social learning, and other modalities in "blended" programs. Identifying a…

  14. Fetal Implications of Diagnostic Radiation Exposure During Pregnancy: Evidence-based Recommendations.

    PubMed

    Rimawi, Bassam H; Green, Victoria; Lindsay, Michael

    2016-06-01

    The purpose of this article is to review the fetal and long-term implications of diagnostic radiation exposure during pregnancy. Evidence-based recommendations for radiologic imaging modalities utilizing exposure of diagnostic radiation during pregnancy, including conventional screen-film mammography, digital mammography, tomosynthesis, and contrast-enhanced mammography are described.

  15. Cognitive Load Theory and Music Instruction

    ERIC Educational Resources Information Center

    Owens, Paul; Sweller, John

    2008-01-01

    In two experiments, the principles of cognitive load theory were applied to the design of alternatives to conventional music instruction hypothesised to facilitate learning. Experiment 1 demonstrated that spatial integration of visual text and musical notation, and dual-modal delivery of auditory text and musical notation, were superior to the…

  16. Assessment of Galileo modal test results for mathematical model verification

    NASA Technical Reports Server (NTRS)

    Trubert, M.

    1984-01-01

    The modal test program for the Galileo Spacecraft was completed at the Jet Propulsion Laboratory in the summer of 1983. The multiple sine dwell method was used for the baseline test. The Galileo Spacecraft is a rather complex 2433 kg structure made of a central core on which seven major appendages representing 30 percent of the total mass are attached, resulting in a high modal density structure. The test revealed a strong nonlinearity in several major modes. This nonlinearity discovered in the course of the test necessitated running additional tests at the unusually high response levels of up to about 21 g. The high levels of response were required to obtain a model verification valid at the level of loads for which the spacecraft was designed. Because of the high modal density and the nonlinearity, correlation between the dynamic mathematical model and the test results becomes a difficult task. Significant changes in the pre-test analytical model are necessary to establish confidence in the upgraded analytical model used for the final load verification. This verification, using a test verified model, is required by NASA to fly the Galileo Spacecraft on the Shuttle/Centaur launch vehicle in 1986.

  17. Integrated Remote Sensing Modalities for Classification at a Legacy Test Site

    NASA Astrophysics Data System (ADS)

    Lee, D. J.; Anderson, D.; Craven, J.

    2016-12-01

    Detecting, locating, and characterizing suspected underground nuclear test sites is of interest to the worldwide nonproliferation monitoring community. Remote sensing provides both cultural and surface geological information over a large search area in a non-intrusive manner. We have characterized a legacy nuclear test site at the Nevada National Security Site (NNSS) using an aerial system based on RGB imagery, light detection and ranging, and hyperspectral imaging. We integrate these different remote sensing modalities to perform pattern recognition and classification tasks on the test site. These tasks include detecting cultural artifacts and exotic materials. We evaluate if the integration of different remote sensing modalities improves classification performance.

  18. Diagnosis and Characterization of Patellofemoral Instability: Review of Available Imaging Modalities.

    PubMed

    Haj-Mirzaian, Arya; Thawait, Gaurav K; Tanaka, Miho J; Demehri, Shadpour

    2017-06-01

    Patellofemoral instability (PI) is defined as single or multiple episodes of patellar dislocation. Imaging modalities are useful for characterization of patellar malalignment, maltracking, underlying morphologic abnormalities, and stabilizing soft-tissue injuries. Using these findings, orthopedic surgeons can decide when to operate, determine the best operation, and measure degree of correction postoperatively in PI patients. Also, these methods assist with PI diagnosis in some suspicious cases. Magnetic resonance imaging is the preferred method especially in the setting of acute dislocations. Multidetector computed tomography allows a more accurate assessment for malalignment such as patellar tilt and lateral subluxation and secondary osteoarthritis. Dynamic magnetic resonance imaging and 4-dimensional computed tomography have been introduced for better kinematic assessment of the patellofemoral maltracking during extension-flexion motions. In this review article, we will discuss the currently available evidence regarding both the conventional and the novel imaging modalities that can be used for diagnosis and characterization of PI.

  19. Imaging Ultrasound Guidance and on-line Estimation of Thermal Behavior in HIFU Exposed Targets

    NASA Astrophysics Data System (ADS)

    Chauhan, Sunita; Haryanto, Amir

    2006-05-01

    Elevated temperatures have been used for many years to combat several diseases including treatment of certain types of cancers/tumors. High Intensity Focused Ultrasound (HIFU) has emerged as a potential non-invasive modality for trackless targeting of deep-seated cancers of human body. For the procedures which require thermal elevation such as hyperthermia and tissue ablation, temperature becomes a parameter of vital importance in order to monitor the treatment on-line. Also, embedding invasive temperature probes for this purpose beats the supremacy of the non-invasive ablating modality. In this paper, we describe the use of a non-invasive and inexpensive conventional imaging ultrasound modality for lesion positioning and estimation of thermal behavior of the tissue on exposure to HIFU. Representative results of our online lesion tracking algorithm for discerning lesioning behavior using image capture, processing and phase-shift measurements are presented.

  20. Loanwords and Vocabulary Size Test Scores: A Case of Different Estimates for Different L1 Learners

    ERIC Educational Resources Information Center

    Laufer, Batia; McLean, Stuart

    2016-01-01

    The article investigated how the inclusion of loanwords in vocabulary size tests affected the test scores of two L1 groups of EFL learners: Hebrew and Japanese. New BNC- and COCA-based vocabulary size tests were constructed in three modalities: word form recall, word form recognition, and word meaning recall. Depending on the test modality, the…

  1. Role of conventional radiology and MRi defecography of pelvic floor hernias

    PubMed Central

    2013-01-01

    Background Purpose of the study is to define the role of conventional radiology and MRI in the evaluation of pelvic floor hernias in female pelvic floor disorders. Methods A MEDLINE and PubMed search was performed for journals before March 2013 with MeSH major terms 'MR Defecography' and 'pelvic floor hernias'. Results The prevalence of pelvic floor hernias at conventional radiology was higher if compared with that at MRI. Concerning the hernia content, there were significantly more enteroceles and sigmoidoceles on conventional radiology than on MRI, whereas, in relation to the hernia development modalities, the prevalence of elytroceles, edroceles, and Douglas' hernias at conventional radiology was significantly higher than that at MRI. Conclusions MRI shows lower sensitivity than conventional radiology in the detection of pelvic floor hernias development. The less-invasive MRI may have a role in a better evaluation of the entire pelvic anatomy and pelvic organ interaction especially in patients with multicompartmental defects, planned for surgery. PMID:24267789

  2. Research on natural frequency based on modal test for high speed vehicles

    NASA Astrophysics Data System (ADS)

    Ma, Guangsong; He, Guanglin; Guo, Yachao

    2018-04-01

    High speed vehicle as a vibration system, resonance generated in flight may be harmful to high speed vehicles. It is possible to solve the resonance problem by acquiring the natural frequency of the high-speed aircraft and then taking some measures to avoid the natural frequency of the high speed vehicle. Therefore, In this paper, the modal test of the high speed vehicle was carried out by using the running hammer method and the PolyMAX modal parameter identification method. Firstly, the total frequency response function, coherence function of the high speed vehicle are obtained by the running hammer stimulation test, and through the modal assurance criterion (MAC) to determine the accuracy of the estimated parameters. Secondly, the first three order frequencies, the pole steady state diagram of the high speed vehicles is obtained by the PolyMAX modal parameter identification method. At last, the natural frequency of the vibration system was accurately obtained by the running hammer method.

  3. Four novel prosthodontic methods for managing upper airway resistance syndrome: an investigative analysis revealing the efficacy of the new nasopharyngeal aperture guard appliance.

    PubMed

    Venkat, R; Gopichander, N; Vasantakumar, M

    2010-01-01

    Obstructive sleep apnea is the most frequent cause for insomnia in the populace. Snoring is mulled over as the potential factor that can lead the sequel to obstructive sleep apnea. Although the etiology and deterrence measures for snoring are yet to be undoubtedly clarified by our scientific sorority, various means of surgical corrections have been affirmed and put into practice, with a substantial degree of success. Despite this, it is implicit that a noninvasive method of managing obstructive sleep apnea is more relevant for overcoming this condition. This manuscript intends to establish how snoring can be controlled prosthodontically by different modalities of scientifically defensible approaches. The most effective among the modalities was affirmed as the investigative analyses of the treatment outcomes with each modality. NOVEL METHODS: Four new methods of managing obstructive sleep apnea--uvula lift appliance, uvula and velopharynx lift appliance, nasopharyngeal aperture guard, and soft palate lift appliance were demonstrated through this article. The four new modalities stated and one conventional modality of mandibular advancement appliance for managing obstructive sleep apnea, a total of five types of appliance therapies, were described with case reports for each. Five individuals undergoing the appliance therapy were chosen for each modality. The treatment outcome with each modality was examined by analysis of clinical predictors and also by means of standard investigation, with nasal and oral endoscopic analyses. Among the five types of appliance therapies, the nasopharyngeal aperture guard provided the best treatment outcome in terms of clinical predictors and endoscopic analyses. Nasopharyngeal aperture guard, the novel method stated in this article is the better modality for managing obstructive sleep apnea, among the five different appliance therapies.

  4. Modal Test/Analysis Correlation of Space Station Structures Using Nonlinear Sensitivity

    NASA Technical Reports Server (NTRS)

    Gupta, Viney K.; Newell, James F.; Berke, Laszlo; Armand, Sasan

    1992-01-01

    The modal correlation problem is formulated as a constrained optimization problem for validation of finite element models (FEM's). For large-scale structural applications, a pragmatic procedure for substructuring, model verification, and system integration is described to achieve effective modal correlation. The space station substructure FEM's are reduced using Lanczos vectors and integrated into a system FEM using Craig-Bampton component modal synthesis. The optimization code is interfaced with MSC/NASTRAN to solve the problem of modal test/analysis correlation; that is, the problem of validating FEM's for launch and on-orbit coupled loads analysis against experimentally observed frequencies and mode shapes. An iterative perturbation algorithm is derived and implemented to update nonlinear sensitivity (derivatives of eigenvalues and eigenvectors) during optimizer iterations, which reduced the number of finite element analyses.

  5. Modal test/analysis correlation of Space Station structures using nonlinear sensitivity

    NASA Technical Reports Server (NTRS)

    Gupta, Viney K.; Newell, James F.; Berke, Laszlo; Armand, Sasan

    1992-01-01

    The modal correlation problem is formulated as a constrained optimization problem for validation of finite element models (FEM's). For large-scale structural applications, a pragmatic procedure for substructuring, model verification, and system integration is described to achieve effective modal correlations. The space station substructure FEM's are reduced using Lanczos vectors and integrated into a system FEM using Craig-Bampton component modal synthesis. The optimization code is interfaced with MSC/NASTRAN to solve the problem of modal test/analysis correlation; that is, the problem of validating FEM's for launch and on-orbit coupled loads analysis against experimentally observed frequencies and mode shapes. An iterative perturbation algorithm is derived and implemented to update nonlinear sensitivity (derivatives of eigenvalues and eigenvectors) during optimizer iterations, which reduced the number of finite element analyses.

  6. Object representation in the bottlenose dolphin (Tursiops truncatus): integration of visual and echoic information.

    PubMed

    Harley, H E; Roitblat, H L; Nachtigall, P E

    1996-04-01

    A dolphin performed a 3-alternative matching-to-sample task in different modality conditions (visual/echoic, both vision and echolocation: visual, vision only; echoic, echolocation only). In Experiment 1, training occurred in the dual-modality (visual/echoic) condition. Choice accuracy in tests of all conditions was above chance without further training. In Experiment 2, unfamiliar objects with complementary similarity relations in vision and echolocation were presented in single-modality conditions until accuracy was about 70%. When tested in the visual/echoic condition, accuracy immediately rose (95%), suggesting integration across modalities. In Experiment 3, conditions varied between presentation of sample and alternatives. The dolphin successfully matched familiar objects in the cross-modal conditions. These data suggest that the dolphin has an object-based representational system.

  7. Ares I-X Launch Vehicle Modal Test Overview

    NASA Technical Reports Server (NTRS)

    Buehrle, Ralph D.; Bartolotta, Paul A.; Templeton, Justin D.; Reaves, Mercedes C.; Horta, Lucas G.; Gaspar, James L.; Parks, Russell A.; Lazor, Daniel R.

    2010-01-01

    The first test flight of NASA's Ares I crew launch vehicle, called Ares I-X, is scheduled for launch in 2009. Ares IX will use a 4-segment reusable solid rocket booster from the Space Shuttle heritage with mass simulators for the 5th segment, upper stage, crew module and launch abort system. Flight test data will provide important information on ascent loads, vehicle control, separation, and first stage reentry dynamics. As part of hardware verification, a series of modal tests were designed to verify the dynamic finite element model (FEM) used in loads assessments and flight control evaluations. Based on flight control system studies, the critical modes were the first three free-free bending mode pairs. Since a test of the free-free vehicle is not practical within project constraints, modal tests for several configurations in the nominal integration flow were defined to calibrate the FEM. A traceability study by Aerospace Corporation was used to identify the critical modes for the tested configurations. Test configurations included two partial stacks and the full Ares I-X launch vehicle on the Mobile Launcher Platform. This paper provides an overview for companion papers in the Ares I-X Modal Test Session. The requirements flow down, pre-test analysis, constraints and overall test planning are described.

  8. Priming within and across modalities: exploring the nature of rCBF increases and decreases.

    PubMed

    Badgaiyan, R D; Schacter, D L; Alpert, N M

    2001-02-01

    Neuroimaging studies suggest that within-modality priming is associated with reduced regional cerebral blood flow (rCBF) in the extrastriate area, whereas cross-modality priming is associated with increased rCBF in prefrontal cortex. To characterize the nature of rCBF changes in within- and cross-modality priming, we conducted two neuroimaging experiments using positron emission tomography (PET). In experiment 1, rCBF changes in within-modality auditory priming on a word stem completion task were observed under same- and different-voice conditions. Both conditions were associated with decreased rCBF in extrastriate cortex. In the different-voice condition there were additional rCBF changes in the middle temporal gyrus and prefrontal cortex. Results suggest that the extrastriate involvement in within-modality priming is sensitive to a change in sensory modality of target stimuli between study and test, but not to a change in the feature of a stimulus within the same modality. In experiment 2, we studied cross-modality priming on a visual stem completion test after encoding under full- and divided-attention conditions. Increased rCBF in the anterior prefrontal cortex was observed in the full- but not in the divided-attention condition. Because explicit retrieval is compromised after encoding under the divided-attention condition, prefrontal involvement in cross-modality priming indicates recruitment of an aspect of explicit retrieval mechanism. The aspect of explicit retrieval that is most likely to be involved in cross-modality priming is the familiarity effect. Copyright 2001 Academic Press.

  9. Active control of a flexible structure using a modal positive position feedback controller

    NASA Technical Reports Server (NTRS)

    Poh, S.; Baz, A.

    1990-01-01

    The feasibility of a new Modal Positive Position Feedback (MPPF) strategy in controlling the vibration of a complex flexible structure using a single piezo-electric active structural member is demonstrated. The control strategy generates its control forces by manipulating only the modal position signals of the structure to provide a damping action to undamped modes. This is in contrast to conventional modal controllers that rely in their operation on negative feedback of both the modal position and velocity. The proposed strategy is very simple to design and implement as it designs the controller at the uncoupled modal level and utilizes simple first order filters to achieve the Positive Position Feedback effect. The performance of the new strategy is enhanced by augmenting it with a time sharing strategy to share a small number of actuators between larger number of modes. The effectiveness of the new strategy is validated experimentally on a flexible box-type structure that has four bays and its first two bending modes are 2.015 and 6.535 Hz respectively. A single piezo-electric actuator is utilized as an active structural member to control several transverse bending modes of the structure. The performance of the active control system is determined in the time and the frequency domains. The results are compared with those obtained when using the Independent Modal Space Control (IMSC) of Meirovitch. The experimental results suggest the potential of the proposed strategy as a viable means for controlling the vibration of large flexible structures in real time.

  10. Thermal effects of diagnostic ultrasound in an anthropomorphic skull model.

    PubMed

    Vyskocil, E; Pfaffenberger, S; Kollmann, C; Gleiss, A; Nawratil, G; Kastl, S; Unger, E; Aumayr, K; Schuhfried, O; Huber, K; Wojta, J; Gottsauner-Wolf, M

    2012-12-01

    Exposure to diagnostic ultrasound (US) can significantly heat biological tissue although conventional routine examinations are regarded as safe. The risk of unwanted thermal effects increases with a high absorption coefficient and extended insonation time. Certain applications of transcranial diagnostic US (TC-US) require prolonged exposure. An anthropomorphic skull model (ASM) was developed to evaluate thermal effects induced by TC-US of different modalities. The objective was to determine whether prolonged continuous TC-US application results in potentially harmful temperature increases. The ASM consists of a human skull with tissue mimicking material and exhibits acoustic and anatomical characteristics of the human skull and brain. Experiments are performed with a diagnostic US device testing four different US modalities: Duplex PW (pulsed wave) Doppler, PW Doppler, color flow Doppler and B-mode. Temperature changes are recorded during 180 minutes of insonation. All measurements revealed significant temperature increases during insonation independent of the US modality. The maximum temperature elevation of + 5.25° C (p < 0.001) was observed on the surface of the skull exposed to duplex PW Doppler. At the bone-brain border a maximum temperature increae of + 2.01 °C (p < 0.001) was noted. Temperature increases within the brain were < 1.23 °C (p = 0.001). The highest values were registered using the duplex PW Doppler modality. TC-US induces significant local heating effects in an ASM. An application duration that extends routine clinical periods causes potentially harmful heating especially in tissue close to bone. TC-US elevates the temperature in the brain mimicking tissue but is not capable of producing harmful temperature increases during routine examinations. However, the risk of thermal injury in brain tissue increases significantly after an exposure time of > 2 hours. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Measuring Working Memory With Digit Span and the Letter-Number Sequencing Subtests From the WAIS-IV: Too Low Manipulation Load and Risk for Underestimating Modality Effects.

    PubMed

    Egeland, Jens

    2015-01-01

    The Wechsler Adult Intelligence Scale (WAIS) is one of the most frequently used tests among psychologists. In the fourth edition of the test (WAIS-IV), the subtests Digit Span and Letter-Number Sequencing are expanded for better measurement of working memory (WM). However, it is not clear whether the new extended tasks contribute sufficient complexity to be sensitive measures of manipulation WM, nor do we know to what degree WM capacity differs between the visual and the auditory modality because the WAIS-IV only tests the auditory modality. Performance by a mixed sample of 226 patients referred for neuropsychological examination on the Digit Span and Letter-Number Sequencing subtests from the WAIS-IV and on Spatial Span from the Wechsler Memory Scale-Third Edition was analyzed in two confirmatory factor analyses to investigate whether a unitary WM model or divisions based on modality or level/complexity best fit the data. The modality model showed the best fit when analyzing summed scores for each task as well as scores for the longest span. The clinician is advised to apply tests with higher manipulation load and to consider testing visual span as well before drawing conclusions about impaired WM from the WAIS-IV.

  12. Acute effect of scapular proprioceptive neuromuscular facilitation (PNF) techniques and classic exercises in adhesive capsulitis: a randomized controlled trial

    PubMed Central

    Balcı, Nilay Comuk; Yuruk, Zeliha Ozlem; Zeybek, Aslican; Gulsen, Mustafa; Tekindal, Mustafa Agah

    2016-01-01

    [Purpose] The aim of our study was to compare the initial effects of scapular proprioceptive neuromuscular facilitation techniques and classic exercise interventions with physiotherapy modalities on pain, scapular dyskinesis, range of motion, and function in adhesive capsulitis. [Subjects and Methods] Fifty-three subjects were allocated to 3 groups: scapular proprioceptive neuromuscular facilitation exercies and physiotherapy modalities, classic exercise and physiotherapy modalities, and only physiotherapy modalities. The intervention was applied in a single session. The Visual Analog Scale, Lateral Scapular Slide Test, range of motion and Simple Shoulder Test were evaluated before and just after the one-hour intervention in the same session (all in one session). [Results] All of the groups showed significant differences in shoulder flexion and abduction range of motion and Simple Shoulder Test scores. There were statistically significant differences in Visual Analog Scale scores in the proprioceptive neuromuscular facilitation and control groups, and no treatment method had significant effect on the Lateral Scapular Slide Test results. There were no statistically significant differences between the groups before and after the intervention. [Conclusion] Proprioceptive neuromuscular facilitation, classic exercise, and physiotherapy modalities had immediate effects on adhesive capsulitis in our study. However, there was no additional benefit of exercises in one session over physiotherapy modalities. Also, an effective treatment regimen for shoulder rehabilitation of adhesive capsulitis patients should include scapular exercises. PMID:27190456

  13. Development of a stationary chest tomosynthesis system using carbon nanotube x-ray source array

    NASA Astrophysics Data System (ADS)

    Shan, Jing

    X-ray imaging system has shown its usefulness for providing quick and easy access of imaging in both clinic settings and emergency situations. It greatly improves the workflow in hospitals. However, the conventional radiography systems, lacks 3D information in the images. The tissue overlapping issue in the 2D projection image result in low sensitivity and specificity. Both computed tomography and digital tomosynthesis, the two conventional 3D imaging modalities, requires a complex gantry to mechanically translate the x-ray source to various positions. Over the past decade, our research group has developed a carbon nanotube (CNT) based x-ray source technology. The CNT x-ray sources allows compacting multiple x-ray sources into a single x-ray tube. Each individual x-ray source in the source array can be electronically switched. This technology allows development of stationary tomographic imaging modalities without any complex mechanical gantries. The goal of this work is to develop a stationary digital chest tomosynthesis (s-DCT) system, and implement it for a clinical trial. The feasibility of s-DCT was investigated. It is found that the CNT source array can provide sufficient x-ray output for chest imaging. Phantom images have shown comparable image qualities as conventional DCT. The s-DBT system was then used to study the effects of source array configurations and tomosynthesis image quality, and the feasibility of a physiological gated s-DCT. Using physical measures for spatial resolution, the 2D source configuration was shown to have improved depth resolution and comparable in-plane resolution. The prospective gated tomosynthesis images have shown substantially reduction of image blur associated with lung motions. The system was also used to investigate the feasibility of using s-DCT as a diagnosis and monitoring tools for cystic fibrosis patients. A new scatter reduction methods for s-DCT was also studied. Finally, a s-DCT system was constructed by retrofitting the source array to a Carestream digital radiography system. The system passed the electrical and radiation safety tests, and was installed in Marsico Hall. The patient trial started in March of 2015, and the first patient was successfully imaged.

  14. Experimental and Theoretical Modal Analysis of Full-Sized Wood Composite Panels Supported on Four Nodes

    PubMed Central

    Guan, Cheng; Zhang, Houjiang; Wang, Xiping; Miao, Hu; Zhou, Lujing; Liu, Fenglu

    2017-01-01

    Key elastic properties of full-sized wood composite panels (WCPs) must be accurately determined not only for safety, but also serviceability demands. In this study, the modal parameters of full-sized WCPs supported on four nodes were analyzed for determining the modulus of elasticity (E) in both major and minor axes, as well as the in-plane shear modulus of panels by using a vibration testing method. The experimental modal analysis was conducted on three full-sized medium-density fiberboard (MDF) and three full-sized particleboard (PB) panels of three different thicknesses (12, 15, and 18 mm). The natural frequencies and mode shapes of the first nine modes of vibration were determined. Results from experimental modal testing were compared with the results of a theoretical modal analysis. A sensitivity analysis was performed to identify the sensitive modes for calculating E (major axis: Ex and minor axis: Ey) and the in-plane shear modulus (Gxy) of the panels. Mode shapes of the MDF and PB panels obtained from modal testing are in a good agreement with those from theoretical modal analyses. A strong linear relationship exists between the measured natural frequencies and the calculated frequencies. The frequencies of modes (2, 0), (0, 2), and (2, 1) under the four-node support condition were determined as the characteristic frequencies for calculation of Ex, Ey, and Gxy of full-sized WCPs. The results of this study indicate that the four-node support can be used in free vibration test to determine the elastic properties of full-sized WCPs. PMID:28773043

  15. Temperature Dependent Modal Test/Analysis Correlation of X-34 Fastrac Composite Rocket Nozzle

    NASA Technical Reports Server (NTRS)

    Brown, Andrew M.; Brunty, Joseph A. (Technical Monitor)

    2001-01-01

    A unique high temperature modal test and model correlation/update program has been performed on the composite nozzle of the FASTRAC engine for the NASA X-34 Reusable Launch Vehicle. The program was required to provide an accurate high temperature model of the nozzle for incorporation into the engine system structural dynamics model for loads calculation; this model is significantly different from the ambient case due to the large decrease in composite stiffness properties due to heating. The high-temperature modal test was performed during a hot-fire test of the nozzle. Previously, a series of high fidelity modal tests and finite element model correlation of the nozzle in a free-free configuration had been performed. This model was then attached to a modal-test verified model of the engine hot-fire test stand and the ambient system mode shapes were identified. A reduced set of accelerometers was then attached to the nozzle, the engine fired full-duration, and the frequency peaks corresponding to the ambient nozzle modes individually isolated and tracked as they decreased during the test. To update the finite-element model of the nozzle to these frequency curves, the percentage differences of the anisotropic composite moduli due to temperature variation from ambient, which had been used in the initial modeling and which were obtained by small sample coupon testing, were multiplied by an iteratively determined constant factor. These new properties were used to create high-temperature nozzle models corresponding to 10 second engine operation increments and tied into the engine system model for loads determination.

  16. Conventional vs  invert-grayscale X-ray for diagnosis of pneumothorax in the emergency setting.

    PubMed

    Musalar, Ekrem; Ekinci, Salih; Ünek, Orkun; Arş, Eda; Eren, Hakan Şevki; Gürses, Bengi; Aktaş, Can

    2017-09-01

    Pneumothorax is a pathologic condition in which air is accumulated between the visceral and parietal pleura. After clinical suspicion, in order to diagnose the severity of the condition, imaging is necessary. By using the help of Picture Archiving and Communication Systems (PACS) direct conventional X-rays are converted to gray-scale and this has become a preferred method among many physicians. Our study design was a case-control study with cross-over design study. Posterior-anterior chest X-rays of patients were evaluated for pneumothorax by 10 expert physicians with at least 3years of experience and who have used inverted gray-scale posterior anterior chest X-ray for diagnosing pneumothorax. The study included posterior anterior chest X-ray images of 268 patients of which 106 were diagnosed with spontaneous pneumothorax and 162 patients used as a control group. The sensitivity of Digital-conventional X-rays was found to be higher than that of inverted gray-scale images (95% CI (2,08-5,04), p<0,01). There was no statistically significant difference between the gold standard and digital-conventional images (95% CI (0,45-2,17), p=0,20), while the evaluations of the gray-scale images were found to be less sensitive for diagnosis (95% CI (3,16-5,67) p<0,01). Inverted gray-scale imaging is not a superior imaging modality over digital-conventional X-ray for the diagnosis of pneumothorax. Prospective studies should be performed where diagnostic potency of inverted gray-scale radiograms is tested against gold standard chest CT. Further research should compare inverted grayscale to lung ultrasound to assess them as alternatives prior to CT. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Initial Experience Using a Telerobotic Ultrasound System for Adult Abdominal Sonography.

    PubMed

    Adams, Scott J; Burbridge, Brent E; Badea, Andreea; Langford, Leanne; Vergara, Vincent; Bryce, Rhonda; Bustamante, Luis; Mendez, Ivar M; Babyn, Paul S

    2017-08-01

    The study sought to assess the feasibility of performing adult abdominal examinations using a telerobotic ultrasound system in which radiologists or sonographers can control fine movements of a transducer and all ultrasound settings from a remote location. Eighteen patients prospectively underwent a conventional sonography examination (using EPIQ 5 [Philips] or LOGIQ E9 [GE Healthcare]) followed by a telerobotic sonography examination (using the MELODY System [AdEchoTech] and SonixTablet [BK Ultrasound]) according to a standardized abdominal imaging protocol. For telerobotic examinations, patients were scanned remotely by a sonographer 2.75 km away. Conventional examinations were read independently from telerobotic examinations. Image quality and acceptability to patients and sonographers was assessed. Ninety-two percent of organs visualized on conventional examinations were sufficiently visualized on telerobotic examinations. Five pathological findings were identified on both telerobotic and conventional examinations, 3 findings were identified using only conventional sonography, and 2 findings were identified using only telerobotic sonography. A paired sample t test showed no significant difference between the 2 modalities in measurements of the liver, spleen, and diameter of the proximal aorta; however, telerobotic assessments overestimated distal aorta and common bile duct diameters and underestimated kidney lengths (P values < .05). All patients responded that they would be willing to have another telerobotic examination. A telerobotic ultrasound system is feasible for performing abdominal ultrasound examinations at a distant location with minimal training and setup requirements and a moderate learning curve. Telerobotic sonography (robotic telesonography) may open up the possibility of remote ultrasound clinics for communities that lack skilled sonographers and radiologists, thereby improving access to care. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  18. Quantitative Analysis of Diffusion-Weighted Imaging for Diagnosis of Puerperal Breast Abscess After Polyacrylamide Hydrogel Augmentation Mammoplasty: Compared with Other Conventional Modalities.

    PubMed

    Liu, Lihua; Long, Miaomiao; Wang, Junping; Liu, Ning; Ge, Xihong; Hu, Zhandong; Shen, Wen

    2015-02-01

    Puerperal breast abscess after polyacrylamide hydrogel (PAAG) augmentation mammoplasty can induce breast auto-inflation resulting in serious consequences. Mammography, ultrasound, and conventional MRI are poor at detecting related PAAG abnormality histologically. We evaluated the value of diffusion-weighted imaging (DWI) in the quantitative analysis of puerperal PAAG abscess after augmentation mammoplasty. This was a retrospective study, and a waiver for informed consent was granted. Sixteen puerperal women with breast discomfort underwent conventional breast non-enhanced MRI and axial DWI using a 3T MR scanner. Qualitative analysis of the signal intensity on DWI and conventional sequences was performed. The apparent diffusion coefficient (ADC) values of the affected and contralateral normal PAAG cysts were measured quantitatively. Paired t test was used to evaluate whether there was significant difference. Both affected and normal PAAG cysts showed equal signal intensity on conventional T1WI and fat saturation T2WI, which were not helpful in detecting puerperal PAAG abscess. However, the affected PAAG cysts had a significantly decreased ADC value of 1.477 ± 0.332 × 10(-3)mm(2)/s and showed obvious hypo-intensity on the ADC map and increased signal intensity on DWI compared with the ADC value of 2.775 ± 0.233 × 10(-3)mm(2)/s of the contralateral normal PAAG cysts. DWI and quantitative measurement of ADC values are of great value for the diagnosis of puerperal PAAG abscess. Standardized MRI should be suggested to these puerperal women with breast discomfort or just for the purpose of check up. DWI should be selected as the essential MRI sequence.

  19. Non-contact modal testing by the electromagnetic acoustic principle: Applications to bending and torsional vibrations of metallic pipes

    NASA Astrophysics Data System (ADS)

    Kim, Hongjin; Park, Chan Il; Lee, Sun Ho; Kim, Yoon Young

    2013-02-01

    This work aims to investigate a possibility of non-contact vibration modal testing for bending and torsional motions of cylindrical bodies such as pipes. Here, a transducer operated by the electromagnetic acoustic coupling principle is newly devised. Depending on vibration modes, bending or torsional, different magnetic circuit configurations are employed to fabricate the transducer. The main characteristic of the proposed transducer is non-contact vibration generation in a test specimen without any mechanical movement of the actuating unit. It can be also used as a non-contact sensing unit if necessary. The validity and the performance of the proposed non-contact modal testing method are checked with several experiments.

  20. The Curious Schools Project: Capturing Nomad Creativity in Teacher Work

    ERIC Educational Resources Information Center

    Hunter, Mary Ann; Emery, Sherridan

    2015-01-01

    The Curious Schools project is a teacher professional learning initiative that aims to provide an insight into--and resource for--creativity in Tasmanian schools. It offers an alternative to conventional models of teacher professional learning by engaging teachers in multi-modal methods of documenting and reflecting on their work as the basis for…

  1. Prevalence, Types and Determinants of Complementary and Alternative Medications among Health Clinic Clients

    ERIC Educational Resources Information Center

    Almousa, H.; Rabie, Faten M.; Alsamghan, Awad S.; Alsaluli, Mobarak; Albqami, Sultan; Almusa, Mona; Al-shahrani, Areej

    2015-01-01

    Complementary and Alternative Medicine (CAM) covers a wide range of over 100 healing approaches, philosophies and therapeutic modalities that are not provided by conventional medicine. Objectives: The study was aimed at identifying the prevalence, types and determinants of CAM use, sources of information about CAM that patients usually depend upon…

  2. 76 FR 41859 - Waiver Petition Docket Numbers FRA-2011-0002, CSX Transportation Railroad, and FRA-2004-17565...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-15

    ... FR 10087) announcing the CSX Transportation Railroad's (CSXT) request for a waiver to operate RailRunner equipment in RailRunner only operations; operate RailRunner equipment commingled with RoadRailer bi-modal equipment; and RailRunner equipment operating behind various conventional railcars. On...

  3. Current controversies in pediatric urologic robotic surgery.

    PubMed

    Trevisani, Lorenzo F M; Nguyen, Hiep T

    2013-01-01

    Minimally invasive surgeries such as conventional laparoscopic surgery and robotic assisted laparoscopic surgery (RALS) have significant advantages over the traditional open surgical approach including lower pain medication requirements and decreased length of hospitalization. However, open surgery has demonstrated better success rates and shorter surgery time when compared to the other modalities. Currently, it is unclear which approach has better long-term clinical outcomes, greater benefits and less cost. There are limited studies in the literature comparing these three different surgical approaches. In this review, we will evaluate the advantages and disadvantages of RALS compared to conventional laparoscopic surgery and open surgery for commonly performed pediatric urological procedures such as pyeloplasty, ureteral reimplantation, complete and partial nephrectomy, bladder augmentation and creation of continent catheterizable channels. Although it is not yet possible to demonstrate the superiority of one single surgical modality over another, RALS has been shown to be feasible, well tolerated and advantageous in reconstructive urological procedures. With experience, the outcomes of RALS are improving, justifying its usage. However, cost remains a significant issue, limiting the accessibility of RALS, which in the future may improve with market competition and device innovation.

  4. Percutaneous Glue Embolization of a Visceral Artery Pseudoaneurysm in a Case of Sickle Cell Anemia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gulati, Gurpreet S.; Gulati, Manpreet S.; Makharia, Govind

    2006-08-15

    Although aneurysmal complications of sickle cell anemia have been described in the intracranial circulation, visceral artery pseudoaneurysms in this disease entity have not previously been reported in the literature. Conventional treatment of visceral pseudoaneurysms has been surgical ligation or resection of the aneurysm. Transcatheter embolization has emerged as an attractive, minimally invasive alternative to surgery in the treatment of these lesions. In certain situations, however, due to the unfavorable angiographic anatomy precluding safe transcatheter embolization, direct percutaneous glue injection of the pseudoaneurysm sac may be considered to achieve successful occlusion of the sac. The procedure may be rendered safer bymore » simultaneous balloon protection of the parent artery. We describe this novel treatment modality in a case of inferior pancreaticoduodenal artery pseudoaneurysm in a patient with sickle cell anemia. Although a complication in the form of glue reflux into the parent vessel occurred that necessitated surgery, this treatment modality may be used in very selected cases (where conventional endovascular embolization techniques are not applicable) after careful selection of the balloon diameter and appropriate concentration of the glue-lipiodol mixture.« less

  5. A framework convention on global health: health for all, justice for all.

    PubMed

    Gostin, Lawrence O

    2012-05-16

    Health inequalities represent perhaps the most consequential global health challenge and yet they persist despite increased funding and innovative programs. The United Nations is revising the Millennium Development Goals (MDGs) that will shape the world for many years to come. What would a transformative post-MDG framework for global health justice look like? A global coalition of civil society and academics--the Joint Action and Learning Initiative on National and Global Responsibilities for Health (JALI)--has formed an international campaign to advocate for a Framework Convention on Global Health (FCGH). Recently endorsed by the UN Secretary-General, the FCGH would reimagine global governance for health, offering a new post-MDG vision. This Special Communication describes the key modalities of an FCGH to illustrate how it would improve health and reduce inequalities. The modalities would include defining national responsibilities for the population's health; defining international responsibilities for reliable, sustainable funding; setting global health priorities; coordinating fragmented activities; reshaping global governance for health; and providing strong global health leadership through the World Health Organization.

  6. Characterization of intraventricular flow patterns in healthy neonates from conventional color-Doppler ultrasound

    NASA Astrophysics Data System (ADS)

    Tejman-Yarden, Shai; Rzasa, Callie; Benito, Yolanda; Alhama, Marta; Leone, Tina; Yotti, Raquel; Bermejo, Javier; Printz, Beth; Del Alamo, Juan C.

    2012-11-01

    Left ventricular vortices have been difficult to visualize in the clinical setting due to the lack of quantitative non-invasive modalities, and this limitation is especially important in pediatrics. We have developed and validated a new technique to reconstruct two-dimensional time-resolved velocity fields in the LV from conventional transthoracic color-Doppler images. This non-invasive modality was used to image LV flow in 10 healthy full-term neonates, ages 24-48 hours. Our results show that, in neonates, a diastolic vortex developed during LV filling, was maintained during isovolumic contraction, and decayed during the ejection period. The vortex was created near the base of the ventricle, moved toward the apex, and then back toward the base and LVOT during ejection. In conclusion, we have characterized for the first time the properties of the LV filling vortex in normal neonates, demonstrating that this vortex channels blood from the inflow to the outflow tract of the LV. Together with existing data from adults, our results confirm that the LV vortex is conserved through adulthood. Funded by NIH Grant R21HL108268.

  7. Fiber-Optic Surface Temperature Sensor Based on Modal Interference.

    PubMed

    Musin, Frédéric; Mégret, Patrice; Wuilpart, Marc

    2016-07-28

    Spatially-integrated surface temperature sensing is highly useful when it comes to controlling processes, detecting hazardous conditions or monitoring the health and safety of equipment and people. Fiber-optic sensing based on modal interference has shown great sensitivity to temperature variation, by means of cost-effective image-processing of few-mode interference patterns. New developments in the field of sensor configuration, as described in this paper, include an innovative cooling and heating phase discrimination functionality and more precise measurements, based entirely on the image processing of interference patterns. The proposed technique was applied to the measurement of the integrated surface temperature of a hollow cylinder and compared with a conventional measurement system, consisting of an infrared camera and precision temperature probe. As a result, the optical technique is in line with the reference system. Compared with conventional surface temperature probes, the optical technique has the following advantages: low heat capacity temperature measurement errors, easier spatial deployment, and replacement of multiple angle infrared camera shooting and the continuous monitoring of surfaces that are not visually accessible.

  8. Perceptual learning in temporal discrimination: asymmetric cross-modal transfer from audition to vision.

    PubMed

    Bratzke, Daniel; Seifried, Tanja; Ulrich, Rolf

    2012-08-01

    This study assessed possible cross-modal transfer effects of training in a temporal discrimination task from vision to audition as well as from audition to vision. We employed a pretest-training-post-test design including a control group that performed only the pretest and the post-test. Trained participants showed better discrimination performance with their trained interval than the control group. This training effect transferred to the other modality only for those participants who had been trained with auditory stimuli. The present study thus demonstrates for the first time that training on temporal discrimination within the auditory modality can transfer to the visual modality but not vice versa. This finding represents a novel illustration of auditory dominance in temporal processing and is consistent with the notion that time is primarily encoded in the auditory system.

  9. Intranasal Insulin for Improving Cognitive Function in Multiple Sclerosis

    DTIC Science & Technology

    2017-10-01

    Insulin, Symbol Digit Modalities Test , Minimal Assessment of Cognitive Function in Multiple Sclerosis 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF...going to evaluate if intranasal insulin improves cognition in people with MS, as assessed by standardized cognitive assessment tests . 2. KEYWORDS...Multiple Sclerosis, Cognitive Impairment, Neurodegenerative diseases, Intranasal Insulin, Symbol Digit Modalities Test , Minimal Assessment of Cognitive

  10. Integrative Therapies for Low Back Pain That Include Complementary and Alternative Medicine Care: A Systematic Review

    PubMed Central

    Rose, Kevin; Kadar, Gena E.

    2014-01-01

    Study Design: Systematic review of the literature. Objective: To evaluate whether an integrated approach that includes different Complementary and Alternative Medicine (CAM) therapies combined or CAM therapies combined with conventional medical care is more effective for the management of low back pain (LBP) than single modalities alone. Summary of Background Data: LBP is one of the leading causes of disability worldwide, yet its optimal management is still unresolved. Methods: The PRISMA Statement guidelines were followed. The Cochrane Back Review Group scale was used to rate the quality of the studies found. Results: Twenty-one studies were found that met the inclusion criteria. The CAM modalities used in the studies included spinal manipulative therapy, acupuncture, exercise therapy, physiotherapy, massage therapy, and a topical ointment. Twenty studies included acupuncture and/or spinal manipulative therapy. Nine high quality studies showed that integrative care was clinically effective for the management of LBP. Spinal manipulative therapy combined with exercise therapy and acupuncture combined with conventional medical care or with exercise therapy appears to be promising approaches to the management of chronic cases of LBP. Conclusions: There is support in the literature for integrated CAM and conventional medical therapy for the management of chronic LBP. Further research into the integrated management of LBP is clearly needed to provide better guidance for patients and clinicians. PMID:25568825

  11. Non-Contact Inspection of Composites Using Air-Coupled Ultrasound

    NASA Astrophysics Data System (ADS)

    Peters, J.; Kommareddy, V.; Liu, Z.; Fei, D.; Hsu, D.

    2003-03-01

    Conventional ultrasonic tests are conducted using water as a transmitting medium. Water coupled ultrasound cannot be applied to certain water-sensitive or porous materials and is more difficult to use in the field. In contrast, air-coupled ultrasound is non-contact and has clear advantages over water-coupled testing. The technology of air-coupled ultrasound has gained maturity in recent years. Some systems have become commercially available and researchers are pursuing several different modalities of air-coupled transduction. This paper reports our experience of applying air-coupled ultrasound to the inspection of flaws, damage, and normal internal structures of composite parts. Through-transmission C-scans at 400 kHz using a focused receiver has resolution sufficient to image honeycomb cells in the sandwich core. With the transmitter and receiver on the same side of a laminate. Lamb waves were generated and used for the imaging of substructures. Air-coupled scan results are presented for flaw detection and damage in aircraft composite structures.

  12. A Cross-Modal Assessment of Reading Achievement in Children.

    ERIC Educational Resources Information Center

    Webb, Kathryn; And Others

    1982-01-01

    This study examined the ability of the Listen and Look (LL) test of cross-modal perception and the Metropolitan Readiness Test (MRT) to predict reading achievement. Data from 79 first-grade pupils were analyzed. Both the LL and MRT demonstrated predictive validity. (Author/BW)

  13. Modalities of Thinking: State and Trait Effects on Cross-Frequency Functional Independent Brain Networks.

    PubMed

    Milz, Patricia; Pascual-Marqui, Roberto D; Lehmann, Dietrich; Faber, Pascal L

    2016-05-01

    Functional states of the brain are constituted by the temporally attuned activity of spatially distributed neural networks. Such networks can be identified by independent component analysis (ICA) applied to frequency-dependent source-localized EEG data. This methodology allows the identification of networks at high temporal resolution in frequency bands of established location-specific physiological functions. EEG measurements are sensitive to neural activity changes in cortical areas of modality-specific processing. We tested effects of modality-specific processing on functional brain networks. Phasic modality-specific processing was induced via tasks (state effects) and tonic processing was assessed via modality-specific person parameters (trait effects). Modality-specific person parameters and 64-channel EEG were obtained from 70 male, right-handed students. Person parameters were obtained using cognitive style questionnaires, cognitive tests, and thinking modality self-reports. EEG was recorded during four conditions: spatial visualization, object visualization, verbalization, and resting. Twelve cross-frequency networks were extracted from source-localized EEG across six frequency bands using ICA. RMANOVAs, Pearson correlations, and path modelling examined effects of tasks and person parameters on networks. Results identified distinct state- and trait-dependent functional networks. State-dependent networks were characterized by decreased, trait-dependent networks by increased alpha activity in sub-regions of modality-specific pathways. Pathways of competing modalities showed opposing alpha changes. State- and trait-dependent alpha were associated with inhibitory and automated processing, respectively. Antagonistic alpha modulations in areas of competing modalities likely prevent intruding effects of modality-irrelevant processing. Considerable research suggested alpha modulations related to modality-specific states and traits. This study identified the distinct electrophysiological cortical frequency-dependent networks within which they operate.

  14. Mini-extracorporeal circulation technology, conventional bypass and prime displacement in isolated coronary and aortic valve surgery: a propensity-matched in-hospital and survival analysis.

    PubMed

    Ariyaratnam, Priyadharshanan; Mclean, Lindsay A; Cale, Alexander; Chaudhry, Mubarak A; Vijayan, Ajith; Richards, Neil; Jarvis, Martin A; Haqzad, Yama; Ngaage, Dumbor; Cowen, Michael E; Loubani, Mahmoud

    2018-02-14

    Conventional cardiopulmonary bypass is the most commonly used means of artificial circulation in cardiac surgery. However, it suffers from the effects of haemodilution and activation of inflammatory/coagulation cascades. Prime displacement (PD) can offset haemodilution and Mini-Extracorporeal Technology (MIECT) can offset both. So far, no study has compared all of these modalities together; hence, we compared the outcomes of these 3 modalities at our institution. This was a retrospective analysis of our cardiac surgical database. A total of 9626 patients underwent conventional bypass (CB), 3125 patients underwent a modification of CB, called PD, and 904 underwent MIECT. A 1:1 propensity-matching algorithm was employed using IBM SPSS 24 to match (i) 813 MIECT patients with 813 CB patients and (ii) 717 MIECT patients with 717 PD patients. The patients included coronary artery bypass grafting and valve surgery. MIECT had significantly (P < 0.05) longer bypass and cross-clamp times compared to CB and PD. MIECT had significantly higher rates of postoperative atrial fibrillation associated with it compared to CB. The mean red cell blood transfusion was significantly lower in the MIECT group compared to the CB group as was the mean platelet transfusion and fresh frozen plasma transfusion. The overall 5-year survival was higher in the MIECT group compared to the CB group (log-rank, P = 0.018). Between the MIECT and the PD groups, we found the incidence of renal failure and gastrointestinal complications to be significantly higher in the PD group compared to the MIECT group. MIECT has short-term advantages over CB and PD. However, due to the retrospective limitations of the study, including calendar time bias, a multicentre randomized controlled trial comparing all 3 modalities will be beneficial for the larger cardiac community. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. MPLM On-Orbit Interface Dynamic Flexibility Modal Test

    NASA Technical Reports Server (NTRS)

    Bookout, Paul S.; Rodriguez, Pedro I.; Tinson, Ian; Fleming, Paolo

    2001-01-01

    Now that the International Space Station (ISS) is being constructed, payload developers have to not only verify the Shuttle-to-payload interface, but also the interfaces their payload will have with the ISS. The Multi Purpose Logistic Module (MPLM) being designed and built by Alenia Spazio in Torino, Italy is one such payload. The MPLM is the primary carrier for the ISS Payload Racks, Re-supply Stowage Racks, and the Resupply Stowage Platforms to re-supply the ISS with food, water, experiments, maintenance equipment and etc. During the development of the MPLM there was no requirement for verification of the on-orbit interfaces with the ISS. When this oversight was discovered, all the dynamic test stands had already been disassembled. A method was needed that would not require an extensive testing stand and could be completed in a short amount of time. The residual flexibility testing technique was chosen. The residual flexibility modal testing method consists of measuring the free-free natural frequencies and mode shapes along with the interface frequency response functions (FRF's). Analytically, the residual flexibility method has been investigated in detail by, MacNeal, Martinez, Carne, and Miller, and Rubin, but has not been implemented extensively for model correlation due to difficulties in data acquisition. In recent years improvement of data acquisition equipment has made possible the implementation of the residual flexibility method as in Admire, Tinker, and Ivey, and Klosterman and Lemon. The residual flexibility modal testing technique is applicable to a structure with distinct points (DOF) of contact with its environment, such as the MPLM-to-Station interface through the Common Berthing Mechanism (CBM). The CBM is bolted to a flange on the forward cone of the MPLM. During the fixed base test (to verify Shuttle interfaces) some data was gathered on the forward cone panels. Even though there was some data on the forward cones, an additional modal test was performed to better characterize its behavior. The CBM mounting flange is the only remaining structure of the MPLM that no test data was available. This paper discusses the implementation of the residual flexibility modal testing technique on the CBM flange and the modal test of the forward cone panels.

  16. Effectiveness of three just-in-time training modalities for N-95 mask fit testing.

    PubMed

    Jones, David; Stoler, Genevieve; Suyama, Joe

    2013-01-01

    To compare and contrast three different training modalities for fit testing N-95 respirator face masks. Block randomized interventional study. Urban university. Two hundred eighty-nine medical students. Students were randomly assigned to video, lecture, or slide show to evaluate the effectiveness of the methods for fit testing large groups of people. Ease of fit and success of fit for each instructional technique. Mask 1 was a Kimberly-Clark duckbill N-95 respirator mask, and mask 2 was a 3M™ carpenters N-95 respirator mask. "Ease of fit" was defined as the ability to successfully don a mask in less than 30 seconds. "Success of fit" was defined as the ability to correctly don a mask in one try. There were no statistical differences by training modality for either mask regarding ease of fit or success of fit. There were no differences among video presentation, small group demonstration, and self-directed slide show just-in-time training modalities for ease of fit or success of fit N-95 respirator mask fitting. Further study is needed to explore more effective fit training modalities.

  17. Low-energy laser biostimulation therapy of musculoskeletal disorders: clinical study

    NASA Astrophysics Data System (ADS)

    Filonenko, Natalia; Livshitz, Oleg; Salansky, Norman M.

    1992-06-01

    215 patients (86 males and 129 females, average age 60.3 years) suffering from musculoskeletal and neuromuscular disorders, both chronic and acute, were treated by low energy lasers. Most patients failed to improve in spite of the fact that different conventional treatment modalities were implemented. Some of them were unable to tolerate drugs because of allergy or gastrointestinal intolerance. The photobiostimulation system FABULIGHTTM (IMM Inc., Canada) with adjustable output parameters for both red and infrared wavelength was used. Different modalities of LELBT were used: local and generalized stimulation of tender points and affected areas. Stiffness, swelling, range of motion and pain were assessed. 65% of symptoms improvement was obtained in average.

  18. Multislice CT imaging of ruptured left sinus of Valsalva aneurysm with fistulous track between left sinus and right atrium.

    PubMed

    Pampapati, Praveenkumar; Rao, Hejmadi Tati Gururaj; Radhesh, Srinivasan; Anand, Hejjaji Krishnamurthy; Praveen, Lokkur Srinivasamurthy

    2011-01-01

    Sinus of valsalva aneurysm is a rare condition arising from any of the three aortic sinuses. Among them, an aneurysm arising from the left coronary sinus is the rarest. Most of these cases were earlier diagnosed using echocardiography and conventional angiography. But with the availability of advanced imaging modalities like 64 slice cardiac CT and MR modalities, this condition can be accurately assessed noninvasively. We report a case of ruptured aneurysm originating from the left coronary sinus with a long windsock type of fistulous track between the aneurysm and right atrium evaluated by 64 slice cardiac CT imaging. This was later confirmed perioperatively.

  19. Influence of Telecommunication Modality, Internet Transmission Quality, and Accessories on Speech Perception in Cochlear Implant Users

    PubMed Central

    Koller, Roger; Guignard, Jérémie; Caversaccio, Marco; Kompis, Martin; Senn, Pascal

    2017-01-01

    Background Telecommunication is limited or even impossible for more than one-thirds of all cochlear implant (CI) users. Objective We sought therefore to study the impact of voice quality on speech perception with voice over Internet protocol (VoIP) under real and adverse network conditions. Methods Telephone speech perception was assessed in 19 CI users (15-69 years, average 42 years), using the German HSM (Hochmair-Schulz-Moser) sentence test comparing Skype and conventional telephone (public switched telephone networks, PSTN) transmission using a personal computer (PC) and a digital enhanced cordless telecommunications (DECT) telephone dual device. Five different Internet transmission quality modes and four accessories (PC speakers, headphones, 3.5 mm jack audio cable, and induction loop) were compared. As a secondary outcome, the subjective perceived voice quality was assessed using the mean opinion score (MOS). Results Speech telephone perception was significantly better (median 91.6%, P<.001) with Skype compared with PSTN (median 42.5%) under optimal conditions. Skype calls under adverse network conditions (data packet loss > 15%) were not superior to conventional telephony. In addition, there were no significant differences between the tested accessories (P>.05) using a PC. Coupling a Skype DECT phone device with an audio cable to the CI, however, resulted in higher speech perception (median 65%) and subjective MOS scores (3.2) than using PSTN (median 7.5%, P<.001). Conclusions Skype calls significantly improve speech perception for CI users compared with conventional telephony under real network conditions. Listening accessories do not further improve listening experience. Current Skype DECT telephone devices do not fully offer technical advantages in voice quality. PMID:28438727

  20. Influence of Telecommunication Modality, Internet Transmission Quality, and Accessories on Speech Perception in Cochlear Implant Users.

    PubMed

    Mantokoudis, Georgios; Koller, Roger; Guignard, Jérémie; Caversaccio, Marco; Kompis, Martin; Senn, Pascal

    2017-04-24

    Telecommunication is limited or even impossible for more than one-thirds of all cochlear implant (CI) users. We sought therefore to study the impact of voice quality on speech perception with voice over Internet protocol (VoIP) under real and adverse network conditions. Telephone speech perception was assessed in 19 CI users (15-69 years, average 42 years), using the German HSM (Hochmair-Schulz-Moser) sentence test comparing Skype and conventional telephone (public switched telephone networks, PSTN) transmission using a personal computer (PC) and a digital enhanced cordless telecommunications (DECT) telephone dual device. Five different Internet transmission quality modes and four accessories (PC speakers, headphones, 3.5 mm jack audio cable, and induction loop) were compared. As a secondary outcome, the subjective perceived voice quality was assessed using the mean opinion score (MOS). Speech telephone perception was significantly better (median 91.6%, P<.001) with Skype compared with PSTN (median 42.5%) under optimal conditions. Skype calls under adverse network conditions (data packet loss > 15%) were not superior to conventional telephony. In addition, there were no significant differences between the tested accessories (P>.05) using a PC. Coupling a Skype DECT phone device with an audio cable to the CI, however, resulted in higher speech perception (median 65%) and subjective MOS scores (3.2) than using PSTN (median 7.5%, P<.001). Skype calls significantly improve speech perception for CI users compared with conventional telephony under real network conditions. Listening accessories do not further improve listening experience. Current Skype DECT telephone devices do not fully offer technical advantages in voice quality. ©Georgios Mantokoudis, Roger Koller, Jérémie Guignard, Marco Caversaccio, Martin Kompis, Pascal Senn. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 24.04.2017.

  1. Comparison of DIC and LDV for practical vibration and modal measurements

    NASA Astrophysics Data System (ADS)

    Reu, Phillip L.; Rohe, Daniel P.; Jacobs, Laura D.

    2017-03-01

    We compare laser Doppler vibrometry (LDV) and digital image correlation (DIC) for use in full-field vibration and modal testing. This was done using a simultaneously measured 3D displacement field on a flat 7-in. corner-supported metal plate using pseudorandom excitation via a shaker. We complete a detailed comparison between the techniques and discuss the pros and cons of each. The results show that either technique can be used for quantifying the modal information with the LDV providing better out-of-plane displacement resolution and equivalent in-plane resolution. The strain calculation is considered better in the DIC approach due to the direct tie to the surface displacements. While the LDV does not lose its place as the gold standard for modal testing, DIC has introduced a new and competitive approach that will have significant advantages in certain testing regimes.

  2. Myeloid-derived suppressor cells

    PubMed Central

    Chandra, Dinesh; Gravekamp, Claudia

    2013-01-01

    While conventional anticancer therapies, including surgical resection, radiotherapy, and/or chemotherapy, are relatively efficient at eliminating primary tumors, these treatment modalities are largely ineffective against metastases. At least in part, this reflects the rather inefficient delivery of conventional anticancer agents to metastatic lesions. We have recently demonstrated that myeloid-derived suppressor cells (MDSCs) can be used as cellular missiles to selectively deliver a radioisotope-coupled attenuated variant of Listeria monocytogenes to both primary and metastatic neoplastic lesions in mice with pancreatic cancer. This novel immunotherapeutic intervention robustly inhibited tumor growth while promoting a dramatic decrease in the number of metastases. PMID:24427545

  3. Myeloid-derived suppressor cells: Cellular missiles to target tumors.

    PubMed

    Chandra, Dinesh; Gravekamp, Claudia

    2013-11-01

    While conventional anticancer therapies, including surgical resection, radiotherapy, and/or chemotherapy, are relatively efficient at eliminating primary tumors, these treatment modalities are largely ineffective against metastases. At least in part, this reflects the rather inefficient delivery of conventional anticancer agents to metastatic lesions. We have recently demonstrated that myeloid-derived suppressor cells (MDSCs) can be used as cellular missiles to selectively deliver a radioisotope-coupled attenuated variant of Listeria monocytogenes to both primary and metastatic neoplastic lesions in mice with pancreatic cancer. This novel immunotherapeutic intervention robustly inhibited tumor growth while promoting a dramatic decrease in the number of metastases.

  4. Integrative oncology in Indian subcontinent: an overview.

    PubMed

    Ramamoorthy, Ananthalakshmi; Janardhanan, Sunitha; Jeevakarunyam, Sathiyajeeva; Jeddy, Nadheem; Eagappan, Senthil

    2015-03-01

    Integrative oncology is a combination of one where complementary and alternative medicine (CAM) with conventional cancer treatment modalities is used to manage symptoms, control side-effects and improve the state of mental wellbeing. The ancient Indian medicinal approach in cancer treatment and management has a wide array of herbs and practices. There is an increasing demand for traditional and natural medicine by the cancer patients. The conventional oncologic surgeons and physicians should be aware of the role of cCAM that are available in Indian subcontinent and provide a treatment that focuses on the physical and mental state of wellness in combating cancer.

  5. Encoding Modality Can Affect Memory Accuracy via Retrieval Orientation

    ERIC Educational Resources Information Center

    Pierce, Benton H.; Gallo, David A.

    2011-01-01

    Research indicates that false memory is lower following visual than auditory study, potentially because visual information is more distinctive. In the present study we tested the extent to which retrieval orientation can cause a modality effect on memory accuracy. Participants studied unrelated words in different modalities, followed by criterial…

  6. Unconscious Cross-Modal Priming of Auditory Sound Localization by Visual Words

    ERIC Educational Resources Information Center

    Ansorge, Ulrich; Khalid, Shah; Laback, Bernhard

    2016-01-01

    Little is known about the cross-modal integration of unconscious and conscious information. In the current study, we therefore tested whether the spatial meaning of an unconscious visual word, such as "up", influences the perceived location of a subsequently presented auditory target. Although cross-modal integration of unconscious…

  7. Active Case Finding for Communicable Diseases in Prison Settings: Increasing Testing Coverage and Uptake Among the Prison Population in the European Union/European Economic Area

    PubMed Central

    Vroling, Hilde; Babudieri, Sergio; Monarca, Roberto; Vonk Noordegraaf-Schouten, Marije; Beer, Netta; Gomes Dias, Joana; O’Moore, Éamonn; Hedrich, Dagmar; Oordt-Speets, Anouk

    2018-01-01

    Abstract Prison populations are disproportionally affected by communicable diseases when compared with the general community because of a complex mix of socioeconomic determinants and environmental factors. Tailored and adequate health care provision in prisons has the potential to reach vulnerable and underserved groups and address their complex needs. We investigated the available evidence on modalities and effectiveness of active case-finding interventions in prisons by searching PubMed, Embase, and the Cochrane Library for records on prison and active case finding with no language limit. Conference abstracts and unpublished research reports also were retrieved. We analyzed the findings by testing modality, outcomes, and study quality. The included 90 records—63 peer-reviewed, 26 from gray literature, and 1 systematic review—reported variously on viral hepatitis, human immunodeficiency virus, sexually transmitted infections, and tuberculosis. No records were retrieved for other communicable diseases. Provider-initiated opt-in testing was the most frequently investigated modality. Testing at entry and provider-initiated testing were reported to result in comparatively higher uptake ranges. However, no comparative studies were identified that reported statistically significant differences between testing modalities. Positivity rates among tested inmates ranged broadly but were generally high for all diseases. The evidence on active case finding in correctional facilities is limited, heterogeneous, and of low quality, making it challenging to draw conclusions on the effect of different testing modalities. Scale-up of provider-initiated testing in European correctional facilities could substantially reduce the undiagnosed fraction and, hence, prevent additional disease transmission in both prison settings and the community at large. PMID:29648594

  8. Multishaker modal testing

    NASA Technical Reports Server (NTRS)

    Craig, Roy R., Jr.

    1987-01-01

    The major accomplishments of this research are: (1) the refinement and documentation of a multi-input, multi-output modal parameter estimation algorithm which is applicable to general linear, time-invariant dynamic systems; (2) the development and testing of an unsymmetric block-Lanzcos algorithm for reduced-order modeling of linear systems with arbitrary damping; and (3) the development of a control-structure-interaction (CSI) test facility.

  9. Effectiveness of Integrative Modalities for Pain and Anxiety in Children and Adolescents with Cancer: A Systematic Review

    PubMed Central

    Thrane, Susan

    2014-01-01

    Throughout the trajectory of the cancer experience, children and adolescents will likely face pain and anxiety in a variety of circumstances. Integrative therapies may be used either alone or as an adjunct to standard analgesics. Children are often very receptive to integrative therapies such as music, art, guided imagery, massage, therapeutic play, distraction, and other modalities (Doellman, 2003). The effect of integrative modalities on pain and anxiety in children with cancer has not been systematically examined across the entire cancer experience. An in-depth search of PubMed, CINAHL, MedLine, PsychInfo, and Web of Science, integrative medicine journals, and the reference lists of review articles using the search terms pain, anxiety, pediatric, child*, oncology, cancer, neoplasm, complementary, integrative, non-conventional, and unconventional yielded 164 articles. Of these, 25 warranted full-text review. Cohen’s d calculations show medium (d=.70) to extremely large (8.57) effect sizes indicating that integrative interventions may be very effective for pain and anxiety in children undergoing cancer treatment. Integrative modalities warrant further study with larger sample sizes to better determine their effectiveness in this population. PMID:24371260

  10. Modal Survey Test of the SOTV 2X3 Meter Off-Axis Inflatable Concentrator

    NASA Technical Reports Server (NTRS)

    Engberg, Robert C.; Lassiter, John O.; McGee, Jennie K.

    2000-01-01

    NASA's Marshall Space Flight Center has had several projects involving inflatable space structures. Projects in solar thermal propulsion have had the most involvement, primarily inflatable concentrators. A flight project called Shooting Star Experiment initiated the first detailed design, analysis and testing effort involving an inflatable concentrator that supported a Fresnel lens. The lens was to concentrate the sun's rays to provide an extremely large heat transfer for an experimental solar propulsion engine. Since the conclusion of this experiment, research and development activities for solar propulsion at Marshall Space Flight Center have continued both in the solar propulsion engine technology as well as inflatable space structures. Experience gained in conducting modal survey tests of inflatable structures for the Shooting Star Experiment has been used by dynamic test engineers at Marshall Space Flight Center to conduct a modal survey test on a Solar Orbital Transfer Vehicle (SOTV) off-axis inflatable concentrator. This paper describes how both previously learned test methods and new test methods that address the unique test requirements for inflatable structures were used. Effects of the inherent nonlinear response of the inflatable concentrator on test methods and test results are noted as well. Nine analytical mode shapes were successfully correlated to test mode shapes. The paper concludes with several "lessons learned" applicable to future dynamics testing and shows how Marshall Space Flight Center has utilized traditional and new methods for modal survey testing of inflatable space structures.

  11. Perceptual Learning Style and Learning Proficiency: A Test of the Hypothesis

    ERIC Educational Resources Information Center

    Kratzig, Gregory P.; Arbuthnott, Katherine D.

    2006-01-01

    Given the potential importance of using modality preference with instruction, the authors tested whether learning style preference correlated with memory performance in each of 3 sensory modalities: visual, auditory, and kinesthetic. In Study 1, participants completed objective measures of pictorial, auditory, and tactile learning and learning…

  12. Feasibility and safety of exercise stress testing using an anti-gravity treadmill with Tc-99m tetrofosmin single-photon emission computed tomography (SPECT) myocardial perfusion imaging: A pilot non-randomized controlled study.

    PubMed

    Daly, Patrick; Kayse, Regina; Rudick, Steven; Robbins, Nathan; Scheler, Jennifer; Harris, David; O'Donnell, Robert; Dwivedi, Alok K; Gerson, Myron C

    2017-08-31

    Exercise is the AHA/ACC guideline-recommended stress modality for myocardial perfusion imaging, but many patients are unable to exercise to target heart rate on a conventional treadmill. We examined the feasibility and safety of stress imaging using an anti-gravity treadmill in patients with perceived poor exercise capacity. 49 patients were recruited for stress testing by anti-gravity treadmill (n = 29) or to a regadenoson control group (n = 20). Seventeen anti-gravity test patients (59%) reached target heart rate obviating the need for a pharmacologic stress agent. Adverse effects of the anti-gravity treadmill were limited to minor muscle aches in 5 subjects. Stress myocardial perfusion image quality judged by 3 blinded readers on a 5-point scale was comparable for the anti-gravity treadmill (4.30 ± SD 0.87) vs pharmacologic stress (4.28 ± SD 0.66). Stress testing using an anti-gravity treadmill is feasible and may help some patients safely achieve target heart rate.

  13. Analysis of swept-sine runs during modal identification

    NASA Astrophysics Data System (ADS)

    Gloth, G.; Sinapius, M.

    2004-11-01

    Experimental modal analysis of large aerospace structures in Europe combine nowadays the benefits of the very reliable but time-consuming phase resonance method and the application of phase separation techniques evaluating frequency response functions (FRF). FRFs of a test structure can be determined by a variety of means. Applied excitation signal waveforms include harmonic signals like stepped-sine excitation, periodic signals like multi-sine excitation, transient signals like impulse and swept-sine excitation, and stochastic signals like random. The current article focuses on slow swept-sine excitation which is a good trade-off between magnitude of excitation level needed for large aircraft and testing time. However, recent ground vibration tests (GVTs) brought up that reliable modal data from swept-sine test runs depend on a proper data processing. The article elucidates the strategy of modal analysis based on swept-sine excitation. The standards for the application of slowly swept sinusoids defined by the international organisation for standardisation in ISO 7626 part 2 are critically reviewed. The theoretical background of swept-sine testing is expounded with particular emphasis to the transition through structural resonances. The effect of different standard procedures of data processing like tracking filter, fast Fourier transform (FFT), and data reduction via averaging are investigated with respect to their influence on the FRFs and modal parameters. Particular emphasis is given to FRF distortions evoked by unsuitable data processing. All data processing methods are investigated on a numerical example. Their practical usefulness is demonstrated on test data taken from a recent GVT on a large aircraft. The revision of ISO 7626 part 2 is suggested regarding the application of slow swept-sine excitation. Recommendations about the proper FRF estimation from slow swept-sine excitation are given in order to enable the optimisation on these applications for future modal survey tests of large aerospace structures.

  14. Hard-X-ray dark-field imaging using a grating interferometer.

    PubMed

    Pfeiffer, F; Bech, M; Bunk, O; Kraft, P; Eikenberry, E F; Brönnimann, Ch; Grünzweig, C; David, C

    2008-02-01

    Imaging with visible light today uses numerous contrast mechanisms, including bright- and dark-field contrast, phase-contrast schemes and confocal and fluorescence-based methods. X-ray imaging, on the other hand, has only recently seen the development of an analogous variety of contrast modalities. Although X-ray phase-contrast imaging could successfully be implemented at a relatively early stage with several techniques, dark-field imaging, or more generally scattering-based imaging, with hard X-rays and good signal-to-noise ratio, in practice still remains a challenging task even at highly brilliant synchrotron sources. In this letter, we report a new approach on the basis of a grating interferometer that can efficiently yield dark-field scatter images of high quality, even with conventional X-ray tube sources. Because the image contrast is formed through the mechanism of small-angle scattering, it provides complementary and otherwise inaccessible structural information about the specimen at the micrometre and submicrometre length scale. Our approach is fully compatible with conventional transmission radiography and a recently developed hard-X-ray phase-contrast imaging scheme. Applications to X-ray medical imaging, industrial non-destructive testing and security screening are discussed.

  15. Spinal muscular atrophy type II (intermediary) and III (Kugelberg-Welander). Evolution of 50 patients with physiotherapy and hydrotherapy in a swimming pool.

    PubMed

    Cunha, M C; Oliveira, A S; Labronici, R H; Gabbai, A A

    1996-09-01

    We added hydrotherapy to 50 patients with spinal muscular atrophy (SMA) who were being treated with individual conventional physiotherapy. Hydrotherapy performed at an approximate temperature of 30 degrees Celsius, twice a week, for thirty minutes in children and forty-five minutes in adults during a 2-year period. The outcome derived from this combined modality of treatment was rated according to physiotherapeutic evaluations, the MMT (Manual Muscular Test), and the Barthel Ladder. Patients were reevaluated at 2-month intervals. After two years of ongoing treatment, we were able to observe that the deformities in hip, knee and foot were progressive in all SMA Type II patients, and in some Type III. Muscle strength stabilized in most SMA Type III patients, and improved in some. MMT was not done in SMA Type II. In all patients we were able to detect an improvement in the Barthel Ladder scale. This study suggests that a measurable improvement in the quality of daily living may be obtained in patients with SMA Types II and III subjected to conventional physiotherapy when associated with hydrotherapy.

  16. Comparison of gesture and conventional interaction techniques for interventional neuroradiology.

    PubMed

    Hettig, Julian; Saalfeld, Patrick; Luz, Maria; Becker, Mathias; Skalej, Martin; Hansen, Christian

    2017-09-01

    Interaction with radiological image data and volume renderings within a sterile environment is a challenging task. Clinically established methods such as joystick control and task delegation can be time-consuming and error-prone and interrupt the workflow. New touchless input modalities may have the potential to overcome these limitations, but their value compared to established methods is unclear. We present a comparative evaluation to analyze the value of two gesture input modalities (Myo Gesture Control Armband and Leap Motion Controller) versus two clinically established methods (task delegation and joystick control). A user study was conducted with ten experienced radiologists by simulating a diagnostic neuroradiological vascular treatment with two frequently used interaction tasks in an experimental operating room. The input modalities were assessed using task completion time, perceived task difficulty, and subjective workload. Overall, the clinically established method of task delegation performed best under the study conditions. In general, gesture control failed to exceed the clinical input approach. However, the Myo Gesture Control Armband showed a potential for simple image selection task. Novel input modalities have the potential to take over single tasks more efficiently than clinically established methods. The results of our user study show the relevance of task characteristics such as task complexity on performance with specific input modalities. Accordingly, future work should consider task characteristics to provide a useful gesture interface for a specific use case instead of an all-in-one solution.

  17. Full-field modal analysis during base motion excitation using high-speed 3D digital image correlation

    NASA Astrophysics Data System (ADS)

    Molina-Viedma, Ángel J.; López-Alba, Elías; Felipe-Sesé, Luis; Díaz, Francisco A.

    2017-10-01

    In recent years, many efforts have been made to exploit full-field measurement optical techniques for modal identification. Three-dimensional digital image correlation using high-speed cameras has been extensively employed for this purpose. Modal identification algorithms are applied to process the frequency response functions (FRF), which relate the displacement response of the structure to the excitation force. However, one of the most common tests for modal analysis involves the base motion excitation of a structural element instead of force excitation. In this case, the relationship between response and excitation is typically based on displacements, which are known as transmissibility functions. In this study, a methodology for experimental modal analysis using high-speed 3D digital image correlation and base motion excitation tests is proposed. In particular, a cantilever beam was excited from its base with a random signal, using a clamped edge join. Full-field transmissibility functions were obtained through the beam and converted into FRF for proper identification, considering a single degree-of-freedom theoretical conversion. Subsequently, modal identification was performed using a circle-fit approach. The proposed methodology facilitates the management of the typically large amounts of data points involved in the DIC measurement during modal identification. Moreover, it was possible to determine the natural frequencies, damping ratios and full-field mode shapes without requiring any additional tests. Finally, the results were experimentally validated by comparing them with those obtained by employing traditional accelerometers, analytical models and finite element method analyses. The comparison was performed by using the quantitative indicator modal assurance criterion. The results showed a high level of correspondence, consolidating the proposed experimental methodology.

  18. LapTrain: multi-modality training curriculum for laparoscopic cholecystectomy-results of a randomized controlled trial.

    PubMed

    Kowalewski, K F; Garrow, C R; Proctor, T; Preukschas, A A; Friedrich, M; Müller, P C; Kenngott, H G; Fischer, L; Müller-Stich, B P; Nickel, F

    2018-02-12

    Multiple training modalities for laparoscopy have different advantages, but little research has been conducted on the benefit of a training program that includes multiple different training methods compared to one method only. This study aimed to evaluate benefits of a combined multi-modality training program for surgical residents. Laparoscopic cholecystectomy (LC) was performed on a porcine liver as the pre-test. Randomization was stratified for experience to the multi-modality Training group (12 h of training on Virtual Reality (VR) and box trainer) or Control group (no training). The post-test consisted of a VR LC and porcine LC. Performance was rated with the Global Operative Assessment of Laparoscopic Skills (GOALS) score by blinded experts. Training (n = 33) and Control (n = 31) were similar in the pre-test (GOALS: 13.7 ± 3.4 vs. 14.7 ± 2.6; p = 0.198; operation time 57.0 ± 18.1 vs. 63.4 ± 17.5 min; p = 0.191). In the post-test porcine LC, Training had improved GOALS scores (+ 2.84 ± 2.85 points, p < 0.001), while Control did not (+ 0.55 ± 2.34 points, p = 0.154). Operation time in the post-test was shorter for Training vs. Control (40.0 ± 17.0 vs. 55.0 ± 22.2 min; p = 0.012). Junior residents improved GOALS scores to the level of senior residents (pre-test: 13.7 ± 2.7 vs. 18.3 ± 2.9; p = 0.010; post-test: 15.5 ± 3.4 vs. 18.8 ± 3.8; p = 0.120) but senior residents remained faster (50.1 ± 20.6 vs. 25.0 ± 1.9 min; p < 0.001). No differences were found between groups on the post-test VR trainer. Structured multi-modality training is beneficial for novices to improve basics and overcome the initial learning curve in laparoscopy as well as to decrease operation time for LCs in different stages of experience. Future studies should evaluate multi-modality training in comparison with single modalities. German Clinical Trials Register DRKS00011040.

  19. Simultaneous measurement of cerebral blood flow and mRNA signals: pixel-based inter-modality correlational analysis.

    PubMed

    Zhao, W; Busto, R; Truettner, J; Ginsberg, M D

    2001-07-30

    The analysis of pixel-based relationships between local cerebral blood flow (LCBF) and mRNA expression can reveal important insights into brain function. Traditionally, LCBF and in situ hybridization studies for genes of interest have been analyzed in separate series. To overcome this limitation and to increase the power of statistical analysis, this study focused on developing a double-label method to measure local cerebral blood flow (LCBF) and gene expressions simultaneously by means of a dual-autoradiography procedure. A 14C-iodoantipyrine autoradiographic LCBF study was first performed. Serial brain sections (12 in this study) were obtained at multiple coronal levels and were processed in the conventional manner to yield quantitative LCBF images. Two replicate sections at each bregma level were then used for in situ hybridization. To eliminate the 14C-iodoantipyrine from these sections, a chloroform-washout procedure was first performed. The sections were then processed for in situ hybridization autoradiography for the probes of interest. This method was tested in Wistar rats subjected to 12 min of global forebrain ischemia by two-vessel occlusion plus hypotension, followed by 2 or 6 h of reperfusion (n=4-6 per group). LCBF and in situ hybridization images for heat shock protein 70 (HSP70) were generated for each rat, aligned by disparity analysis, and analyzed on a pixel-by-pixel basis. This method yielded detailed inter-modality correlation between LCBF and HSP70 mRNA expressions. The advantages of this method include reducing the number of experimental animals by one-half; and providing accurate pixel-based correlations between different modalities in the same animals, thus enabling paired statistical analyses. This method can be extended to permit correlation of LCBF with the expression of multiple genes of interest.

  20. System level mechanical testing of the Clementine spacecraft

    NASA Technical Reports Server (NTRS)

    Haughton, James; Hauser, Joseph; Raynor, William; Lynn, Peter

    1994-01-01

    This paper discusses the system level structural testing that was performed to qualify the Clementine Spacecraft for flight. These tests included spin balance, combined acoustic and axial random vibration, lateral random vibration, quasi-static loads, pyrotechnic shock, modal survey and on-orbit jitter simulation. Some innovative aspects of this effort were: the simultaneously combined acoustic and random vibration test; the mass loaded interface modal survey test; and the techniques used to assess how operating on board mechanisms and thrusters affect sensor vision.

  1. Intensive Hemodialysis and Mortality Risk in Australian and New Zealand Populations.

    PubMed

    Marshall, Mark R; Polkinghorne, Kevan R; Kerr, Peter G; Hawley, Carmel M; Agar, John W M; McDonald, Stephen P

    2016-04-01

    Intensive hemodialysis (HD) is characterized by increased frequency and/or session length compared to conventional HD. Previous analyses from Australia and New Zealand did not suggest benefit with intensive HD, although recent research suggests that relationships have changed. We present updated analyses. Observational cohort study using marginal structural modeling to adjust for changes in renal replacement modality and time-varying medical comorbid conditions. Adults initiating renal replacement therapy since March 31, 1996, followed up through December 31, 2012; this analysis included 40,842 patients over 2,187,689 patient-months. Time-varying renal replacement modality: conventional facility HD (≤3 times per week, ≤6 hours per session), quasi-intensive facility HD (between conventional and intensive), intensive facility HD (≥5 times per week, any hours per session), conventional home HD, quasi-intensive home HD, intensive home HD, peritoneal dialysis, deceased donor kidney transplantation, and living donor kidney transplantation. Patient mortality, with a 3-month lag in primary analyses and 6- and 12-month lags in sensitivity analyses. Conventional facility HD was the reference group. Conventional home HD had a similar mortality risk. For quasi-intensive home HD, mortality risk was lower (HR, 0.56; 95% CI, 0.44-0.73). For intensive home HD, mortality risk was nonsignificantly lower in primary analyses and significantly lower using a 6-month lag (HR, 0.41; 95% CI, 0.20-0.85), but not using a 12-month lag. For quasi-intensive facility HD, mortality risk was nonsignificantly lower in primary analyses, although significantly lower using 6- (HR, 0.41; 95% CI, 0.20-0.85) and 12-month lags (HR, 0.59; 95% CI, 0.44-0.80). Mortality risk was similar between intensive and conventional facility HD. For peritoneal dialysis, mortality risk was greater than for conventional facility HD (HR, 1.07; 95% CI, 1.03-1.12). Kidney transplantation had the lowest mortality risk. Potential residual confounding from limited collection of comorbid condition, socioeconomic, and medication data. There is an emerging HD dose-effect in Australia and New Zealand, with lower mortality risks associated with some of the more intensive HD regimens in these countries. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  2. Clinical utility of indigenously formulated single-vial lyophilized HYNIC-TOC kit in evaluating Gastro-entero Pancreatic neuro endocrine tumours

    PubMed Central

    Shinto, Ajit S; Kamaleshwaran, K; Vyshak, K; Sudhakar, Natarajan; Banerjee, Sharmila; Korde, Aruna; Samuel, Grace; Mallia, Madhav

    2014-01-01

    Objective(s): The objective of this study was to evaluate the performance and utility of 99mTc HYNIC-TOC planar scintigraphy and SPECT/CT in the diagnosis, staging and management of gastroenteropancreatic neuroendocrine tumors (GPNETs). Methods: 22 patients (median age, 46 years) with histologically proven gastro- entero- pancreatic NETs underwent 99mTc HYNIC-TOC whole body scintigraphy and regional SPECT/CT as indicated. Scanning was performed after injection of 370-550 MBq (10-15 mCi) of 99mTc HYNIC-TOC intravenously. Images were evaluated by two experienced nuclear medicine physicians both qualitatively as well as semi quantitatively (tumor to background and tumor to normal liver ratios on SPECT -CT images). Results of SPECT/CT were compared with the results of conventional imaging. Histopathology results and follow-up somatostatin receptor scintigraphy with 99mTc HYNIC TOC or conventional imaging with biochemical markers were considered to be the reference standards. Results: 99mTc HYNIC TOC showed sensitivity and specificity of 87.5% and 85.7%, respectively, for primary tumor and 100% and 86% for metastases. It was better than conventional imaging modalities for the detection of both primary tumor (P<0.001) and metastases (P<0.0001). It changed the management strategy in 6 patients (31.8%) and supported management decisions in 8 patients (36.3%). Conclusion: 99mTc HYNIC TOC SPECT/CT appears to be a highly sensitive and specific modality for the detection and staging of GPNETs. It is better than conventional imaging for the evaluation of GPNETs and can have a significant impact on patient management and planning further therapeutic options. PMID:27408857

  3. Clinical utility of indigenously formulated single-vial lyophilized HYNIC-TOC kit in evaluating Gastro-entero Pancreatic neuro endocrine tumours.

    PubMed

    Shinto, Ajit S; Kamaleshwaran, K; Vyshak, K; Sudhakar, Natarajan; Banerjee, Sharmila; Korde, Aruna; Samuel, Grace; Mallia, Madhav

    2014-01-01

    The objective of this study was to evaluate the performance and utility of (99m)Tc HYNIC-TOC planar scintigraphy and SPECT/CT in the diagnosis, staging and management of gastroenteropancreatic neuroendocrine tumors (GPNETs). 22 patients (median age, 46 years) with histologically proven gastro- entero- pancreatic NETs underwent (99m)Tc HYNIC-TOC whole body scintigraphy and regional SPECT/CT as indicated. Scanning was performed after injection of 370-550 MBq (10-15 mCi) of (99m)Tc HYNIC-TOC intravenously. Images were evaluated by two experienced nuclear medicine physicians both qualitatively as well as semi quantitatively (tumor to background and tumor to normal liver ratios on SPECT -CT images). Results of SPECT/CT were compared with the results of conventional imaging. Histopathology results and follow-up somatostatin receptor scintigraphy with (99m)Tc HYNIC TOC or conventional imaging with biochemical markers were considered to be the reference standards. (99m)Tc HYNIC TOC showed sensitivity and specificity of 87.5% and 85.7%, respectively, for primary tumor and 100% and 86% for metastases. It was better than conventional imaging modalities for the detection of both primary tumor (P<0.001) and metastases (P<0.0001). It changed the management strategy in 6 patients (31.8%) and supported management decisions in 8 patients (36.3%). (99m)Tc HYNIC TOC SPECT/CT appears to be a highly sensitive and specific modality for the detection and staging of GPNETs. It is better than conventional imaging for the evaluation of GPNETs and can have a significant impact on patient management and planning further therapeutic options.

  4. Modal Analysis of Space-rocket Equipment Components

    NASA Astrophysics Data System (ADS)

    Igolkin, A. A.; Safin, A. I.; Prokofiev, A. B.

    2018-01-01

    In order to prevent vibration damage an analysis of natural frequencies and mode shapes of elements of rocket and space technology should be developed. This paper discusses technique of modal analysis on the example of the carrier platform. Modal analysis was performed by using mathematical modeling and laser vibrometer. Experimental data was clarified by using Test.Lab software. As a result of modal analysis amplitude-frequency response of carrier platform was obtained and the parameters of the elasticity was clarified.

  5. Missing Modality Transfer Learning via Latent Low-Rank Constraint.

    PubMed

    Ding, Zhengming; Shao, Ming; Fu, Yun

    2015-11-01

    Transfer learning is usually exploited to leverage previously well-learned source domain for evaluating the unknown target domain; however, it may fail if no target data are available in the training stage. This problem arises when the data are multi-modal. For example, the target domain is in one modality, while the source domain is in another. To overcome this, we first borrow an auxiliary database with complete modalities, then consider knowledge transfer across databases and across modalities within databases simultaneously in a unified framework. The contributions are threefold: 1) a latent factor is introduced to uncover the underlying structure of the missing modality from the known data; 2) transfer learning in two directions allows the data alignment between both modalities and databases, giving rise to a very promising recovery; and 3) an efficient solution with theoretical guarantees to the proposed latent low-rank transfer learning algorithm. Comprehensive experiments on multi-modal knowledge transfer with missing target modality verify that our method can successfully inherit knowledge from both auxiliary database and source modality, and therefore significantly improve the recognition performance even when test modality is inaccessible in the training stage.

  6. Effects of auditory and visual modalities in recall of words.

    PubMed

    Gadzella, B M; Whitehead, D A

    1975-02-01

    Ten experimental conditions were used to study the effects of auditory and visual (printed words, uncolored and colored pictures) modalities and their various combinations with college students. A recall paradigm was employed in which subjects responded in a written test. Analysis of data showed the auditory modality was superior to visual (pictures) ones but was not significantly different from visual (printed words) modality. In visual modalities, printed words were superior to colored pictures. Generally, conditions with multiple modes of representation of stimuli were significantly higher than for conditions with single modes. Multiple modalities, consisting of two or three modes, did not differ significantly from each other. It was concluded that any two modalities of the stimuli presented simultaneously were just as effective as three in recall of stimulus words.

  7. Modal vector estimation for closely spaced frequency modes

    NASA Technical Reports Server (NTRS)

    Craig, R. R., Jr.; Chung, Y. T.; Blair, M.

    1982-01-01

    Techniques for obtaining improved modal vector estimates for systems with closely spaced frequency modes are discussed. In describing the dynamical behavior of a complex structure modal parameters are often analyzed: undamped natural frequency, mode shape, modal mass, modal stiffness and modal damping. From both an analytical standpoint and an experimental standpoint, identification of modal parameters is more difficult if the system has repeated frequencies or even closely spaced frequencies. The more complex the structure, the more likely it is to have closely spaced frequencies. This makes it difficult to determine valid mode shapes using single shaker test methods. By employing band selectable analysis (zoom) techniques and by employing Kennedy-Pancu circle fitting or some multiple degree of freedom (MDOF) curve fit procedure, the usefulness of the single shaker approach can be extended.

  8. The utility of visual analogs of central auditory tests in the differential diagnosis of (central) auditory processing disorder and attention deficit hyperactivity disorder.

    PubMed

    Bellis, Teri James; Billiet, Cassie; Ross, Jody

    2011-09-01

    Cacace and McFarland (2005) have suggested that the addition of cross-modal analogs will improve the diagnostic specificity of (C)APD (central auditory processing disorder) by ensuring that deficits observed are due to the auditory nature of the stimulus and not to supra-modal or other confounds. Others (e.g., Musiek et al, 2005) have expressed concern about the use of such analogs in diagnosing (C)APD given the uncertainty as to the degree to which cross-modal measures truly are analogous and emphasize the nonmodularity of the CANs (central auditory nervous system) and its function, which precludes modality specificity of (C)APD. To date, no studies have examined the clinical utility of cross-modal (e.g., visual) analogs of central auditory tests in the differential diagnosis of (C)APD. This study investigated performance of children diagnosed with (C)APD, children diagnosed with ADHD (attention deficit hyperactivity disorder), and typically developing children on three diagnostic tests of central auditory function and their corresponding visual analogs. The study sought to determine whether deficits observed in the (C)APD group were restricted to the auditory modality and the degree to which the addition of visual analogs aids in the ability to differentiate among groups. An experimental repeated measures design was employed. Participants consisted of three groups of right-handed children (normal control, n=10; ADHD, n=10; (C)APD, n=7) with normal and symmetrical hearing sensitivity, normal or corrected-to-normal visual acuity, and no family or personal history of disorders unrelated to their primary diagnosis. Participants in Groups 2 and 3 met current diagnostic criteria for ADHD and (C)APD. Visual analogs of three tests in common clinical use for the diagnosis of (C)APD were used (Dichotic Digits [Musiek, 1983]; Frequency Patterns [Pinheiro and Ptacek, 1971]; and Duration Patterns [Pinheiro and Musiek, 1985]). Participants underwent two 1 hr test sessions separated by at least 1 wk. Order of sessions (auditory, visual) and tests within each session were counterbalanced across participants. ANCOVAs (analyses of covariance) were used to examine effects of group, modality, and laterality (Dichotic/Dichoptic Digits) or response condition (auditory and visual patterning). In addition, planned univariate ANCOVAs were used to examine effects of group on intratest comparison measures (REA, HLD [Humming-Labeling Differential]). Children with both ADHD and (C)APD performed more poorly overall than typically developing children on all tasks, with the (C)APD group exhibiting the poorest performance on the auditory and visual patterns tests but the ADHD and (C)APD group performing similarly on the Dichotic/Dichoptic Digits task. However, each of the auditory and visual intratest comparison measures, when taken individually, was able to distinguish the (C)APD group from both the normal control and ADHD groups, whose performance did not differ from one another. Results underscore the importance of intratest comparison measures in the interpretation of central auditory tests (American Speech-Language-Hearing Association [ASHA], 2005 ; American Academy of Audiology [AAA], 2010). Results also support the "non-modular" view of (C)APD in which cross-modal deficits would be predicted based on shared neuroanatomical substrates. Finally, this study demonstrates that auditory tests alone are sufficient to distinguish (C)APD from supra-modal disorders, with cross-modal analogs adding little if anything to the differential diagnostic process. American Academy of Audiology.

  9. Sound propagation through a variable area duct - Experiment and theory

    NASA Technical Reports Server (NTRS)

    Silcox, R. J.; Lester, H. C.

    1981-01-01

    A comparison of experiment and theory has been made for the propagation of sound through a variable area axisymmetric duct with zero mean flow. Measurement of the acoustic pressure field on both sides of the constricted test section was resolved on a modal basis for various spinning mode sources. Transmitted and reflected modal amplitudes and phase angles were compared with finite element computations. Good agreement between experiment and computation was obtained over a wide range of frequencies and modal transmission variations. The study suggests that modal transmission through a variable area duct is governed by the throat modal cut-off ratio.

  10. Determination of orthotropic material properties by modal analysis

    NASA Astrophysics Data System (ADS)

    Lai, Junpeng

    The methodology for determination of orthotropic material properties in plane stress condition will be presented. It is applied to orthotropic laminated plates like printed wiring boards. The first part of the thesis will focus on theories and methodologies. The static beam model and vibratory plate model is presented. The methods are validated by operating a series of test on aluminum. In the static tests, deflection and two directions of strain are measured, thus four of the properties will be identified: Ex, Ey, nuxy, nuyx. Moving on to dynamic test, the first ten modes' resonance frequencies are obtained. The technique of modal analysis is adopted. The measured data is processed by FFT and analyzed by curve fitting to extract natural frequencies and mode shapes. With the last material property to be determined, a finite element method using ANSYS is applied. Along with the identified material properties in static tests, and proper initial guess of the unknown shear modulus, an iterative process creates finite element model and conducts modal analysis with the updating model. When the modal analysis result produced by ANSYS matches the natural frequencies acquired by dynamic test, the process will halt. Then we obtained the last material property in plane stress condition.

  11. Modal parameter estimation and monitoring for on-line flight flutter analysis

    NASA Astrophysics Data System (ADS)

    Verboven, P.; Cauberghe, B.; Guillaume, P.; Vanlanduit, S.; Parloo, E.

    2004-05-01

    The clearance of the flight envelope of a new airplane by means of flight flutter testing is time consuming and expensive. Most common approach is to track the modal damping ratios during a number of flight conditions, and hence the accuracy of the damping estimates plays a crucial role. However, aircraft manufacturers desire to decrease the flight flutter testing time for practical, safety and economical reasons by evolving from discrete flight test points to a more continuous flight test pattern. Therefore, this paper presents an approach that provides modal parameter estimation and monitoring for an aircraft with a slowly time-varying structural behaviour that will be observed during a faster and more continuous exploration of the flight envelope. The proposed identification approach estimates the modal parameters directly from input/output Fourier data. This avoids the need for an averaging-based pre-processing of the data, which becomes inapplicable in the case that only short data records are measured. Instead of using a Hanning window to reduce effects of leakage, these transient effects are modelled simultaneously with the dynamical behaviour of the airplane. The method is validated for the monitoring of the system poles during flight flutter testing.

  12. Modal sensing and control of paraboloidal shell structronic system

    NASA Astrophysics Data System (ADS)

    Yue, Honghao; Lu, Yifan; Deng, Zongquan; Tzou, Hornsen

    2018-02-01

    Paraboloidal shells of revolution are commonly used as important components in the field of advanced aerospace structures and aviation mechanical systems. This study is to investigate the modal sensing behavior and the modal vibration control effect of distributed PVDF patches laminated on the paraboloidal shell. A paraboloidal shell sensing and control testing platform is set up first. Frequencies of lower order modes of the shell are obtained with the PVDF sensor and compared with the previous testing results to prove its accuracy. Then sensor patches are laminated on different positions (or different sides) of the shell and tested to reveal the relation between the sensing behaviors and their locations. Finally, a mathematical model of the structronic system is built by parameter identifications and the transfer function is derived. Independent and coupled modal controllers are designed based on the pole placement method and modal vibration control experiments are performed. The amplitude suppression ratio of each mode controlled by the pole placement controller is calculated and compared with the results obtained by using a PPF controller. Advantages of both methods are concluded and suggestions are given on how to choose control algorithm for different purpose.

  13. High temperature latent heat thermal energy storage to augment solar thermal propulsion for microsatellites

    NASA Astrophysics Data System (ADS)

    Gilpin, Matthew R.

    Solar thermal propulsion (STP) offers an unique combination of thrust and efficiency, providing greater total DeltaV capability than chemical propulsion systems without the order of magnitude increase in total mission duration associated with electric propulsion. Despite an over 50 year development history, no STP spacecraft has flown to-date as both perceived and actual complexity have overshadowed the potential performance benefit in relation to conventional technologies. The trend in solar thermal research over the past two decades has been towards simplification and miniaturization to overcome this complexity barrier in an effort finally mount an in-flight test. A review of micro-propulsion technologies recently conducted by the Air Force Research Laboratory (AFRL) has identified solar thermal propulsion as a promising configuration for microsatellite missions requiring a substantial Delta V and recommended further study. A STP system provides performance which cannot be matched by conventional propulsion technologies in the context of the proposed microsatellite ''inspector" requiring rapid delivery of greater than 1500 m/s DeltaV. With this mission profile as the target, the development of an effective STP architecture goes beyond incremental improvements and enables a new class of microsatellite missions. Here, it is proposed that a bi-modal solar thermal propulsion system on a microsatellite platform can provide a greater than 50% increase in Delta V vs. chemical systems while maintaining delivery times measured in days. The realization of a microsatellite scale bi-modal STP system requires the integration of multiple new technologies, and with the exception of high performance thermal energy storage, the long history of STP development has provided "ready" solutions. For the target bi-modal STP microsatellite, sensible heat thermal energy storage is insufficient and the development of high temperature latent heat thermal energy storage is an enabling technology for the platform. The use of silicon and boron as high temperature latent heat thermal energy storage materials has been in the background of solar thermal research for decades without a substantial investigation. This is despite a broad agreement in the literature about the performance benefits obtainable from a latent heat mechanisms which provides a high energy storage density and quasi-isothermal heat release at high temperature. In this work, an experimental approach was taken to uncover the practical concerns associated specifically with applying silicon as an energy storage material. A new solar furnace was built and characterized enabling the creation of molten silicon in the laboratory. These tests have demonstrated the basic feasibility of a molten silicon based thermal energy storage system and have highlighted asymmetric heat transfer as well as silicon expansion damage to be the primary engineering concerns for the technology. For cylindrical geometries, it has been shown that reduced fill factors can prevent damage to graphite walled silicon containers at the expense of decreased energy storage density. Concurrent with experimental testing, a cooling model was written using the "enthalpy method" to calculate the phase change process and predict test section performance. Despite a simplistic phase change model, and experimentally demonstrated complexities of the freezing process, results coincided with experimental data. It is thus possible to capture essential system behaviors of a latent heat thermal energy storage system even with low fidelity freezing kinetics modeling allowing the use of standard tools to obtain reasonable results. Finally, a technological road map is provided listing extant technological concerns and potential solutions. Improvements in container design and an increased understanding of convective coupling efficiency will ultimately enable both high temperature latent heat thermal energy storage and a new class of high performance bi-modal solar thermal spacecraft.

  14. Autofluorescence spectroscopy for multimodal tissues characterization in colitis-associated cancer murine model

    NASA Astrophysics Data System (ADS)

    Dorez, Hugo; Sablong, Raphaël.; Canaple, Laurence; Saint-Jalmes, Hervé; Gaillard, Sophie; Moussata, Driffa; Beuf, Olivier

    2015-07-01

    The purpose of this research project is to assess mice colon wall, using three optical modalities (conventional endoscopy, confocal endomicroscopy and optical spectroscopy) and endoluminal MRI. The study is done in the context of inflammatory bowel disease and colorectal cancer that represent 13% of new cases of cancer, every year in western countries. An optical spectroscopic bench (autofluorescence and reflectance) was developed with a flexible fiber probe. This latter has been combined with a mini multi-purpose rigid endoscope and a confocal endomicroscope. The optical modalities were first used in vivo on SWISS mice. Then, a specific optical a phantom (containing two layers of distinct fluorophores) was developed in order to evaluate our two-channel spectroscopic probe as a basic depth-sensitive measurement tool. The preliminary results show the feasibility to combine such modalities in the same in vivo protocol. Conventional endoscopy is useful to depict inflammation along colon wall. Confocal endomicroscopy provides high-contrasted images of microvascularization. Measured optical spectra both depend on biochemical tissue content and layered structure of the medium. The light collected from one channel is not similar to the other, in terms of intensity and spectroscopic profile as the interaction with the medium observed volume is different. A comparative analysis of the spectra based on our in vitro model exhibits a strong correlation between simple index extracted from spectral data and two main phantom characteristics (fluorophore concentrations and superficial layer thickness). This work suggests that this technique could contribute to assess tissues alterations through autofluorescence spectroscopic measurement under endoscopy.

  15. Spacecraft structural system identification by modal test

    NASA Technical Reports Server (NTRS)

    Chen, J.-C.; Peretti, L. F.; Garba, J. A.

    1984-01-01

    A structural parameter estimation procedure using the measured natural frequencies and kinetic energy distribution as observers is proposed. The theoretical derivation of the estimation procedure is described and its constraints and limitations are explained. This procedure is applied to a large complex spacecraft structural system to identify the inertia matrix using modal test results. The inertia matrix is chosen after the stiffness matrix has been updated by the static test results.

  16. Ground Vibration Test Planning and Pre-Test Analysis for the X-33 Vehicle

    NASA Technical Reports Server (NTRS)

    Bedrossian, Herand; Tinker, Michael L.; Hidalgo, Homero

    2000-01-01

    This paper describes the results of the modal test planning and the pre-test analysis for the X-33 vehicle. The pre-test analysis included the selection of the target modes, selection of the sensor and shaker locations and the development of an accurate Test Analysis Model (TAM). For target mode selection, four techniques were considered, one based on the Modal Cost technique, one based on Balanced Singular Value technique, a technique known as the Root Sum Squared (RSS) method, and a Modal Kinetic Energy (MKE) approach. For selecting sensor locations, four techniques were also considered; one based on the Weighted Average Kinetic Energy (WAKE), one based on Guyan Reduction (GR), one emphasizing engineering judgment, and one based on an optimum sensor selection technique using Genetic Algorithm (GA) search technique combined with a criteria based on Hankel Singular Values (HSV's). For selecting shaker locations, four techniques were also considered; one based on the Weighted Average Driving Point Residue (WADPR), one based on engineering judgment and accessibility considerations, a frequency response method, and an optimum shaker location selection based on a GA search technique combined with a criteria based on HSV's. To evaluate the effectiveness of the proposed sensor and shaker locations for exciting the target modes, extensive numerical simulations were performed. Multivariate Mode Indicator Function (MMIF) was used to evaluate the effectiveness of each sensor & shaker set with respect to modal parameter identification. Several TAM reduction techniques were considered including, Guyan, IRS, Modal, and Hybrid. Based on a pre-test cross-orthogonality checks using various reduction techniques, a Hybrid TAM reduction technique was selected and was used for all three vehicle fuel level configurations.

  17. Parity–time-symmetric circular Bragg lasers: a proposal and analysis

    PubMed Central

    Gu, Jiahua; Xi, Xiang; Ma, Jingwen; Yu, Zejie; Sun, Xiankai

    2016-01-01

    We propose a new type of semiconductor lasers by implementing the concept of parity–time symmetry in a two-dimensional circular Bragg grating structure, where both the real and imaginary parts of the refractive index are modulated along the radial direction. The laser modal properties are analyzed with a transfer-matrix method and are verified with numerical simulation of a practical design. Compared with conventional distributed-feedback lasers with modulation of only the real part of refractive index, the parity–time-symmetric circular Bragg lasers feature reduced threshold and enhanced modal discrimination, which in combination with the intrinsic circularly symmetric, large emission aperture are clear advantages in applications that require mode-hop-free, high-power, single-mode laser operation. PMID:27892933

  18. Development of Immunopathogenesis Strategies to Treat Behçet's Disease

    PubMed Central

    Köse, Osman

    2012-01-01

    Behçet disease is a chronic relapsing vasculitis with unclear etiology and immunopathogenesis. Antigenic stimuli, antigen presenting cells, T cells, monocyte, and neutrophil and endothelial cells are major parts of the pathology of the disease. Understanding of the new pathogenic mechanisms based on molecular structure of the disease helps us in improving the novel therapeutic modalities. These drugs target specific and nonspecific inhibition of the immun system. These therapies include biologic agents, new topical and systemic immunosuppressants, tolerizing agents, and immunoablation. Novel treatment will be promising to treat the especially recalcitrant cases to conventional therapy. In this paper, new aspect of the immunopathogenesis of Behçet's diseases and novel treatment modalities will be discussed. PMID:22550612

  19. Progress in atherosclerotic plaque imaging

    PubMed Central

    Soloperto, Giulia; Casciaro, Sergio

    2012-01-01

    Cardiovascular diseases are the primary cause of mortality in the industrialized world, and arterial obstruction, triggered by rupture-prone atherosclerotic plaques, lead to myocardial infarction and cerebral stroke. Vulnerable plaques do not necessarily occur with flow-limiting stenosis, thus conventional luminographic assessment of the pathology fails to identify unstable lesions. In this review we discuss the currently available imaging modalities used to investigate morphological features and biological characteristics of the atherosclerotic plaque. The different imaging modalities such as ultrasound, magnetic resonance imaging, computed tomography, nuclear imaging and their intravascular applications are illustrated, highlighting their specific diagnostic potential. Clinically available and upcoming methodologies are also reviewed along with the related challenges in their clinical translation, concerning the specific invasiveness, accuracy and cost-effectiveness of these methods. PMID:22937215

  20. Cold atmospheric plasma, a novel promising anti-cancer treatment modality.

    PubMed

    Yan, Dayun; Sherman, Jonathan H; Keidar, Michael

    2017-02-28

    Over the past decade, cold atmospheric plasma (CAP), a near room temperature ionized gas has shown its promising application in cancer therapy. Two CAP devices, namely dielectric barrier discharge and plasma jet, show significantly anti-cancer capacity over dozens of cancer cell lines in vitro and several subcutaneous xenograft tumors in vivo. In contrast to conventional anti-cancer approaches and drugs, CAP is a selective anti-cancer treatment modality. Thus far establishing the chemical and molecular mechanism of the anti-cancer capacity of CAP is far from complete. In this review, we provide a comprehensive introduction of the basics of CAP, state of the art research in this field, the primary challenges, and future directions to cancer biologists.

  1. Comparison of oral nicotinamide adenine dinucleotide (NADH) versus conventional therapy for chronic fatigue syndrome.

    PubMed

    Santaella, María L; Font, Ivonne; Disdier, Orville M

    2004-06-01

    To compare effectiveness of oral therapy with reduced nicotinamide adenine dinucleotide (NADH) to conventional modalities of treatment in patients with chronic fatigue syndrome (CFS). CFS is a potentially disabling condition of unknown etiology. Although its clinical presentation is associated to a myriad of symptoms, fatigue is a universal and essential finding for its diagnosis. No therapeutic regimen has proven effective for this condition. A total of 31 patients fulfilling the Centers for Disease Control criteria for CFS, were randomly assigned to either NADH or nutritional supplements and psychological therapy for 24 months. A thorough medical history, physical examination and completion of a questionnaire on the severity of fatigue and other symptoms were performed each trimester of therapy. In addition, all of them underwent evaluation in terms of immunological parameters and viral antibody titers. Statistical analysis was applied to the demographic data, as well as to symptoms scores at baseline and at each trimester of therapy. The twelve patients who received NADH had a dramatic and statistically significant reduction of the mean symptom score in the first trimester (p < 0.001). However, symptom scores in the subsequent trimesters of therapy were similar in both treatment groups. Elevated IgG and Ig E antibody levels were found in a significant number of patients. Observed effectiveness of NADH over conventional treatment in the first trimester of the trial and the trend of improvement of that modality in the subsequent trimesters should be further assessed in a larger patient sample.

  2. Innovations in diagnostic imaging of localized prostate cancer.

    PubMed

    Pummer, Karl; Rieken, Malte; Augustin, Herbert; Gutschi, Thomas; Shariat, Shahrokh F

    2014-08-01

    In recent years, various imaging modalities have been developed to improve diagnosis, staging, and localization of early-stage prostate cancer (PCa). A MEDLINE literature search of the time frame between 01/2007 and 06/2013 was performed on imaging of localized PCa. Conventional transrectal ultrasound (TRUS) is mainly used to guide prostate biopsy. Contrast-enhanced ultrasound is based on the assumption that PCa tissue is hypervascularized and might be better identified after intravenous injection of a microbubble contrast agent. However, results on its additional value for cancer detection are controversial. Computer-based analysis of the transrectal ultrasound signal (C-TRUS) appears to detect cancer in a high rate of patients with previous biopsies. Real-time elastography seems to have higher sensitivity, specificity, and positive predictive value than conventional TRUS. However, the method still awaits prospective validation. The same is true for prostate histoscanning, an ultrasound-based method for tissue characterization. Currently, multiparametric MRI provides improved tissue visualization of the prostate, which may be helpful in the diagnosis and targeting of prostate lesions. However, most published series are small and suffer from variations in indication, methodology, quality, interpretation, and reporting. Among ultrasound-based techniques, real-time elastography and C-TRUS seem the most promising techniques. Multiparametric MRI appears to have advantages over conventional T2-weighted MRI in the detection of PCa. Despite these promising results, currently, no recommendation for the routine use of these novel imaging techniques can be made. Prospective studies defining the value of various imaging modalities are urgently needed.

  3. Improved visualization of breast cancer features in multifocal carcinoma using phase-contrast and dark-field mammography: an ex vivo study.

    PubMed

    Grandl, Susanne; Scherer, Kai; Sztrókay-Gaul, Anikó; Birnbacher, Lorenz; Willer, Konstantin; Chabior, Michael; Herzen, Julia; Mayr, Doris; Auweter, Sigrid D; Pfeiffer, Franz; Bamberg, Fabian; Hellerhoff, Karin

    2015-12-01

    Conventional X-ray attenuation-based contrast is inherently low for the soft-tissue components of the female breast. To overcome this limitation, we investigate the diagnostic merits arising from dark-field mammography by means of certain tumour structures enclosed within freshly dissected mastectomy samples. We performed grating-based absorption, absolute phase and dark-field mammography of three freshly dissected mastectomy samples containing bi- and multifocal carcinoma using a compact, laboratory Talbot-Lau interferometer. Preoperative in vivo imaging (digital mammography, ultrasound, MRI), postoperative histopathological analysis and ex vivo digital mammograms of all samples were acquired for the diagnostic verification of our results. In the diagnosis of multifocal tumour growth, dark-field mammography seems superior to standard breast imaging modalities, providing a better resolution of small, calcified tumour nodules, demarcation of tumour boundaries with desmoplastic stromal response and spiculated soft-tissue strands extending from an invasive ductal breast cancer. On the basis of selected cases, we demonstrate that dark-field mammography is capable of outperforming conventional mammographic imaging of tumour features in both calcified and non-calcified tumours. Presuming dose optimization, our results encourage further studies on larger patient cohorts to identify those patients that will benefit the most from this promising additional imaging modality. • X-ray dark-field mammography provides significantly improved visualization of tumour features • X-ray dark-field mammography is capable of outperforming conventional mammographic imaging • X-ray dark-field mammography provides imaging sensitivity towards highly dispersed calcium grains.

  4. Integrating Conceptual Knowledge Within and Across Representational Modalities

    PubMed Central

    McNorgan, Chris; Reid, Jackie; McRae, Ken

    2011-01-01

    Research suggests that concepts are distributed across brain regions specialized for processing information from different sensorimotor modalities. Multimodal semantic models fall into one of two broad classes differentiated by the assumed hierarchy of convergence zones over which information is integrated. In shallow models, communication within- and between-modality is accomplished using either direct connectivity, or a central semantic hub. In deep models, modalities are connected via cascading integration sites with successively wider receptive fields. Four experiments provide the first direct behavioral tests of these models using speeded tasks involving feature inference and concept activation. Shallow models predict no within-modal versus cross-modal difference in either task, whereas deep models predict a within-modal advantage for feature inference, but a cross-modal advantage for concept activation. Experiments 1 and 2 used relatedness judgments to tap participants’ knowledge of relations for within- and cross-modal feature pairs. Experiments 3 and 4 used a dual feature verification task. The pattern of decision latencies across Experiments 1 to 4 is consistent with a deep integration hierarchy. PMID:21093853

  5. Statistically generated weighted curve fit of residual functions for modal analysis of structures

    NASA Technical Reports Server (NTRS)

    Bookout, P. S.

    1995-01-01

    A statistically generated weighting function for a second-order polynomial curve fit of residual functions has been developed. The residual flexibility test method, from which a residual function is generated, is a procedure for modal testing large structures in an external constraint-free environment to measure the effects of higher order modes and interface stiffness. This test method is applicable to structures with distinct degree-of-freedom interfaces to other system components. A theoretical residual function in the displacement/force domain has the characteristics of a relatively flat line in the lower frequencies and a slight upward curvature in the higher frequency range. In the test residual function, the above-mentioned characteristics can be seen in the data, but due to the present limitations in the modal parameter evaluation (natural frequencies and mode shapes) of test data, the residual function has regions of ragged data. A second order polynomial curve fit is required to obtain the residual flexibility term. A weighting function of the data is generated by examining the variances between neighboring data points. From a weighted second-order polynomial curve fit, an accurate residual flexibility value can be obtained. The residual flexibility value and free-free modes from testing are used to improve a mathematical model of the structure. The residual flexibility modal test method is applied to a straight beam with a trunnion appendage and a space shuttle payload pallet simulator.

  6. 40 CFR 1045.505 - How do I test engines using discrete-mode or ramped-modal duty cycles?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false How do I test engines using discrete-mode or ramped-modal duty cycles? 1045.505 Section 1045.505 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  7. 40 CFR 1045.505 - How do I test engines using discrete-mode or ramped-modal duty cycles?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false How do I test engines using discrete-mode or ramped-modal duty cycles? 1045.505 Section 1045.505 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  8. 40 CFR 1045.505 - How do I test engines using discrete-mode or ramped-modal duty cycles?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false How do I test engines using discrete-mode or ramped-modal duty cycles? 1045.505 Section 1045.505 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  9. 40 CFR 1051.615 - What are the special provisions for certifying small recreational engines?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... dynamometer using the equipment and procedures of 40 CFR part 1065 with either discrete-mode or ramped-modal... discrete-mode and ramped-modal testing (either in your original application or in an amendment to your... by the Clean Air Act. Measure steady-state emissions as follows: (1) For discrete-mode testing...

  10. Robust energy-absorbing compensators for the ACTEX II test article

    NASA Astrophysics Data System (ADS)

    Blaurock, Carl A.; Miller, David W.; Nye, Ted

    1995-05-01

    The paper addresses the problem of satellite solar panel vibration. A multi-layer vibration control scheme is investigated using a flight test article. Key issues in the active control portion are presented in the paper. The paper discusses the primary control design drivers, which are the time variations in modal frequencies due to configuration and thermal changes. A local control design approach is investigated, but found to be unworkable due to sensor/actuator non-collocation. An alternate design process uses linear robust control techniques, by describing the modal shifts as uncertainties. Multiple modal design, alpha- shifted multiple model, and a feedthrough compensation scheme are examined. Ground and simulation tests demonstrate that the resulting controllers provide significant vibration reduction in the presence of expected system variations.

  11. Dynamic response of NASA Rotor Test Apparatus and Sikorsky S-76 hub mounted in the 80- by 120-Foot Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Peterson, Randall L.; Hoque, Muhammed S.

    1994-01-01

    A shake test was conducted in the 80- by 120-Foot Wind Tunnel at NASA Ames Research Center, using the NASA Ames Rotor Test Apparatus (RTA) and the Sikorsky S-76 rotor hub. The primary objective of this shake test was to determine the modal properties of the RTA, the S-76 rotor hub, and the model support system installed in the wind tunnel. Random excitation was applied at the rotor hub, and vibration responses were measured using accelerometers mounted at various critical locations on the model and the model support system. Transfer functions were computed using the load cell data and the accelerometer responses. The transfer function data were used to compute the system modal parameters with the aid of modal analysis software.

  12. Parametric boundary reconstruction algorithm for industrial CT metrology application.

    PubMed

    Yin, Zhye; Khare, Kedar; De Man, Bruno

    2009-01-01

    High-energy X-ray computed tomography (CT) systems have been recently used to produce high-resolution images in various nondestructive testing and evaluation (NDT/NDE) applications. The accuracy of the dimensional information extracted from CT images is rapidly approaching the accuracy achieved with a coordinate measuring machine (CMM), the conventional approach to acquire the metrology information directly. On the other hand, CT systems generate the sinogram which is transformed mathematically to the pixel-based images. The dimensional information of the scanned object is extracted later by performing edge detection on reconstructed CT images. The dimensional accuracy of this approach is limited by the grid size of the pixel-based representation of CT images since the edge detection is performed on the pixel grid. Moreover, reconstructed CT images usually display various artifacts due to the underlying physical process and resulting object boundaries from the edge detection fail to represent the true boundaries of the scanned object. In this paper, a novel algorithm to reconstruct the boundaries of an object with uniform material composition and uniform density is presented. There are three major benefits in the proposed approach. First, since the boundary parameters are reconstructed instead of image pixels, the complexity of the reconstruction algorithm is significantly reduced. The iterative approach, which can be computationally intensive, will be practical with the parametric boundary reconstruction. Second, the object of interest in metrology can be represented more directly and accurately by the boundary parameters instead of the image pixels. By eliminating the extra edge detection step, the overall dimensional accuracy and process time can be improved. Third, since the parametric reconstruction approach shares the boundary representation with other conventional metrology modalities such as CMM, boundary information from other modalities can be directly incorporated as prior knowledge to improve the convergence of an iterative approach. In this paper, the feasibility of parametric boundary reconstruction algorithm is demonstrated with both simple and complex simulated objects. Finally, the proposed algorithm is applied to the experimental industrial CT system data.

  13. Diary Data Subjected to Cluster Analysis of Intake/Output/Void Habits with Resulting Clusters Compared by Continence Status, Age, Race

    PubMed Central

    Miller, Janis M; Guo, Ying; Rodseth, Sarah Becker

    2011-01-01

    Background Data that incorporate the full complexity of healthy beverage intake and voiding frequency do not exist; therefore, clinicians reviewing bladder habits or voiding diaries for continence care must rely on expert opinion recommendations. Objective To use data-driven cluster analyses to reduce complex voiding diary variables into discrete patterns or data cluster profiles, descriptively name the clusters, and perform validity testing. Method Participants were 352 community women who filled out a 3-day voiding diary. Six variables (void frequency during daytime hours, void frequency during nighttime hours, modal output, total output, total intake, and body mass index) were entered into cluster analyses. The clusters were analyzed for differences by continence status, age, race (Black women, n = 196 White women, n = 156), and for those who were incontinent, by leakage episode severity. Results Three clusters emerged, labeled descriptively as Conventional, Benchmark, and Superplus. The Conventional cluster (68% of the sample) demonstrated mean daily intake of 45 ±13 ounces; mean daily output of 37 ± 15 ounces, mean daily voids 5 ± 2 times, mean modal daytime output 10±0.5 ounces, and mean nighttime voids 1±1 times. The Superplus cluster (7% of the sample) showed double or triple these values across the 5 variables, and the Benchmark cluster (25%) showed values consistent with current popular recommendations on intake and output (e.g., meeting or exceeding the 8 × 8 fluid intake rule of thumb). The clusters differed significantly (p < .05) by age, race, amount of irritating beverages consumed, and incontinence status. Discussion Identification of three discrete clusters provides for a potential parsimonious but data-driven means of classifying individuals for additional epidemiological or clinical study. The clinical utility rests with potential for intervening to move an individual from a high risk to low risk cluster with regards to incontinence. PMID:21317828

  14. Can Music Foster Learning - Effects of Different Text Modalities on Learning and Information Retrieval.

    PubMed

    Lehmann, Janina A M; Seufert, Tina

    2017-01-01

    This study investigates the possibilities of fostering learning based on differences in recall and comprehension after learning with texts which were presented in one of three modalities: either in a spoken, written, or sung version. All three texts differ regarding their processing, especially when considering working memory. Overall, we assume the best recall performance after learning with the written text and the best comprehension performance after learning with the sung text, respectively, compared to both other text modalities. We also analyzed whether the melody of the sung material functions as a mnemonic aid for the learners in the sung text condition. If melody and text of the sung version are closely linked, presentation of the melody during the post-test phase could foster text retrieval. 108 students either learned from a sung text performed by a professional singer, a printed text, or the same text read out loud. Half of the participants worked on the post-test while listening to the melody used for the musical learning material and the other half did not listen to a melody. The written learning modality led to significantly better recall than with the spoken ( d = 0.97) or sung text ( d = 0.78). However, comprehension after learning with the sung modality was significantly superior compared to when learning with the written learning modality ( d = 0.40). Reading leads to more focus on details, which is required to answer recall questions, while listening fosters a general understanding of the text, leading to higher levels of comprehension. Listening to the melody during the post-test phase negatively affected comprehension, irrespective of the modality during the learning phase. This can be explained by the seductive detail effect, as listening to the melody during the post-test phase may distract learners from their main task. In closing, theoretical and practical implications are discussed.

  15. Can Music Foster Learning – Effects of Different Text Modalities on Learning and Information Retrieval

    PubMed Central

    Lehmann, Janina A. M.; Seufert, Tina

    2018-01-01

    This study investigates the possibilities of fostering learning based on differences in recall and comprehension after learning with texts which were presented in one of three modalities: either in a spoken, written, or sung version. All three texts differ regarding their processing, especially when considering working memory. Overall, we assume the best recall performance after learning with the written text and the best comprehension performance after learning with the sung text, respectively, compared to both other text modalities. We also analyzed whether the melody of the sung material functions as a mnemonic aid for the learners in the sung text condition. If melody and text of the sung version are closely linked, presentation of the melody during the post-test phase could foster text retrieval. 108 students either learned from a sung text performed by a professional singer, a printed text, or the same text read out loud. Half of the participants worked on the post-test while listening to the melody used for the musical learning material and the other half did not listen to a melody. The written learning modality led to significantly better recall than with the spoken (d = 0.97) or sung text (d = 0.78). However, comprehension after learning with the sung modality was significantly superior compared to when learning with the written learning modality (d = 0.40). Reading leads to more focus on details, which is required to answer recall questions, while listening fosters a general understanding of the text, leading to higher levels of comprehension. Listening to the melody during the post-test phase negatively affected comprehension, irrespective of the modality during the learning phase. This can be explained by the seductive detail effect, as listening to the melody during the post-test phase may distract learners from their main task. In closing, theoretical and practical implications are discussed. PMID:29375429

  16. Visualization and Classification of Deeply Seated Collateral Networks in Moyamoya Angiopathy with 7T MRI.

    PubMed

    Matsushige, T; Kraemer, M; Sato, T; Berlit, P; Forsting, M; Ladd, M E; Jabbarli, R; Sure, U; Khan, N; Schlamann, M; Wrede, K H

    2018-06-07

    Collateral networks in Moyamoya angiopathy have a complex angioarchitecture difficult to comprehend on conventional examinations. This study aimed to evaluate morphologic patterns and the delineation of deeply seated collateral networks using ultra-high-field MRA in comparison with conventional DSA. Fifteen white patients with Moyamoya angiopathy were investigated in this prospective trial. Sequences acquired at 7T were TOF-MRA with 0.22 × 0.22 × 0.41 mm 3 resolution and MPRAGE with 0.7 × 0.7 × 0.7 mm 3 resolution. Four raters evaluated the presence of deeply seated collateral networks and image quality in a consensus reading of DSA, TOF-MRA, and MPRAGE using a 5-point scale in axial source images and maximum intensity projections. Delineation of deeply seated collateral networks by different imaging modalities was compared by means of the McNemar test, whereas image quality was compared using the Wilcoxon signed-rank test. The relevant deeply seated collateral networks were classified into 2 categories and 6 pathways. A total of 100 collateral networks were detected on DSA; 106, on TOF-MRA; and 73, on MPRAGE. Delineation of deeply seated collateral networks was comparable between TOF-MRA and DSA ( P = .25); however, both were better than MPRAGE ( P < .001). This study demonstrates excellent delineation of 6 distinct deeply seated collateral network pathways in Moyamoya angiopathy in white adults using 7T TOF-MRA, comparable to DSA. © 2018 by American Journal of Neuroradiology.

  17. Contrast-enhanced spectral mammography in patients referred from the breast cancer screening programme.

    PubMed

    Lobbes, Marc B I; Lalji, Ulrich; Houwers, Janneke; Nijssen, Estelle C; Nelemans, Patty J; van Roozendaal, Lori; Smidt, Marjolein L; Heuts, Esther; Wildberger, Joachim E

    2014-07-01

    Feasibility studies have shown that contrast-enhanced spectral mammography (CESM) increases diagnostic accuracy of mammography. We studied diagnostic accuracy of CESM in patients referred from the breast cancer screening programme, who have a lower disease prevalence than previously published papers on CESM. During 6 months, all women referred to our hospital were eligible for CESM. Two radiologists blinded to the final diagnosis provided BI-RADS classifications for conventional mammography and CESM. Statistical significance of differences between mammography and CESM was calculated using McNemar's test. Receiver operating characteristic (ROC) curves were constructed for both imaging modalities. Of the 116 eligible women, 113 underwent CESM. CESM increased sensitivity to 100.0% (+3.1%), specificity to 87.7% (+45.7%), PPV to 76.2% (+36.5%) and NPV to 100.0% (+2.9%) as compared to mammography. Differences between conventional mammography and CESM were statistically significant (p < 0.0001). A similar trend was observed in the ROC curve. For conventional mammography, AUC was 0.779. With CESM, AUC increased to 0.976 (p < 0.0001). In addition, good agreement between tumour diameters measured using CESM, breast MRI and histopathology was observed. CESM increases diagnostic performance of conventional mammography, even in lower prevalence patient populations such as referrals from breast cancer screening. • CESM is feasible in the workflow of referrals from routine breast screening. • CESM is superior to mammography, even in low disease prevalence populations. • CESM has an extremely high negative predictive value for breast cancer. • CESM is comparable to MRI in assessment of breast cancer extent. • CESM is comparable to histopathology in assessment of breast cancer extent.

  18. Characterization of identification errors and uses in localization of poor modal correlation

    NASA Astrophysics Data System (ADS)

    Martin, Guillaume; Balmes, Etienne; Chancelier, Thierry

    2017-05-01

    While modal identification is a mature subject, very few studies address the characterization of errors associated with components of a mode shape. This is particularly important in test/analysis correlation procedures, where the Modal Assurance Criterion is used to pair modes and to localize at which sensors discrepancies occur. Poor correlation is usually attributed to modeling errors, but clearly identification errors also occur. In particular with 3D Scanning Laser Doppler Vibrometer measurement, many transfer functions are measured. As a result individual validation of each measurement cannot be performed manually in a reasonable time frame and a notable fraction of measurements is expected to be fairly noisy leading to poor identification of the associated mode shape components. The paper first addresses measurements and introduces multiple criteria. The error measures the difference between test and synthesized transfer functions around each resonance and can be used to localize poorly identified modal components. For intermediate error values, diagnostic of the origin of the error is needed. The level evaluates the transfer function amplitude in the vicinity of a given mode and can be used to eliminate sensors with low responses. A Noise Over Signal indicator, product of error and level, is then shown to be relevant to detect poorly excited modes and errors due to modal property shifts between test batches. Finally, a contribution is introduced to evaluate the visibility of a mode in each transfer. Using tests on a drum brake component, these indicators are shown to provide relevant insight into the quality of measurements. In a second part, test/analysis correlation is addressed with a focus on the localization of sources of poor mode shape correlation. The MACCo algorithm, which sorts sensors by the impact of their removal on a MAC computation, is shown to be particularly relevant. Combined with the error it avoids keeping erroneous modal components. Applied after removal of poor modal components, it provides spatial maps of poor correlation, which help localizing mode shape correlation errors and thus prepare the selection of model changes in updating procedures.

  19. Inconsistent emotion recognition deficits across stimulus modalities in Huntington׳s disease.

    PubMed

    Rees, Elin M; Farmer, Ruth; Cole, James H; Henley, Susie M D; Sprengelmeyer, Reiner; Frost, Chris; Scahill, Rachael I; Hobbs, Nicola Z; Tabrizi, Sarah J

    2014-11-01

    Recognition of negative emotions is impaired in Huntington׳s Disease (HD). It is unclear whether these emotion-specific problems are driven by dissociable cognitive deficits, emotion complexity, test cue difficulty, or visuoperceptual impairments. This study set out to further characterise emotion recognition in HD by comparing patterns of deficits across stimulus modalities; notably including for the first time in HD, the more ecologically and clinically relevant modality of film clips portraying dynamic facial expressions. Fifteen early HD and 17 control participants were tested on emotion recognition from static facial photographs, non-verbal vocal expressions and one second dynamic film clips, all depicting different emotions. Statistically significant evidence of impairment of anger, disgust and fear recognition was seen in HD participants compared with healthy controls across multiple stimulus modalities. The extent of the impairment, as measured by the difference in the number of errors made between HD participants and controls, differed according to the combination of emotion and modality (p=0.013, interaction test). The largest between-group difference was seen in the recognition of anger from film clips. Consistent with previous reports, anger, disgust and fear were the most poorly recognised emotions by the HD group. This impairment did not appear to be due to task demands or expression complexity as the pattern of between-group differences did not correspond to the pattern of errors made by either group; implicating emotion-specific cognitive processing pathology. There was however evidence that the extent of emotion recognition deficits significantly differed between stimulus modalities. The implications in terms of designing future tests of emotion recognition and care giving are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Development of large field-of-view two photon microscopy for imaging mouse cortex (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Bumstead, Jonathan; Côté, Daniel C.; Culver, Joseph P.

    2017-02-01

    Spontaneous neuronal activity has been measured at cellular resolution in mice, zebrafish, and C. elegans using optical sectioning microscopy techniques, such as light sheet microscopy (LSM) and two photon microscopy (TPM). Recent improvements in these modalities and genetically encoded calcium indicators (GECI's) have enabled whole brain imaging of calcium dynamics in zebrafish and C. elegans. However, these whole brain microscopy studies have not been extended to mice due to the limited field of view (FOV) of TPM and the cumbersome geometry of LSM. Conventional TPM is restricted to diffraction limited imaging over this small FOV (around 500 x 500 microns) due to the use of high magnification objectives (e.g. 1.0 NA; 20X) and the aberrations introduced by relay optics used in scanning the beam across the sample. To overcome these limitations, we have redesigned the entire optical path of the two photon microscope (scanning optics and objective lens) to support a field of view of Ø7 mm with relatively high spatial resolution (<10 microns). Using optical engineering software Zemax, we designed our system with commercially available optics that minimize astigmatism, field curvature, chromatic focal shift, and vignetting. Performance of the system was also tested experimentally with fluorescent beads in agarose, fixed samples, and in vivo structural imaging. Our large-FOV TPM provides a modality capable of studying distributed brain networks in mice at cellular resolution.

  1. Experimental Validation of Normalized Uniform Load Surface Curvature Method for Damage Localization

    PubMed Central

    Jung, Ho-Yeon; Sung, Seung-Hoon; Jung, Hyung-Jo

    2015-01-01

    In this study, we experimentally validated the normalized uniform load surface (NULS) curvature method, which has been developed recently to assess damage localization in beam-type structures. The normalization technique allows for the accurate assessment of damage localization with greater sensitivity irrespective of the damage location. In this study, damage to a simply supported beam was numerically and experimentally investigated on the basis of the changes in the NULS curvatures, which were estimated from the modal flexibility matrices obtained from the acceleration responses under an ambient excitation. Two damage scenarios were considered for the single damage case as well as the multiple damages case by reducing the bending stiffness (EI) of the affected element(s). Numerical simulations were performed using MATLAB as a preliminary step. During the validation experiments, a series of tests were performed. It was found that the damage locations could be identified successfully without any false-positive or false-negative detections using the proposed method. For comparison, the damage detection performances were compared with those of two other well-known methods based on the modal flexibility matrix, namely, the uniform load surface (ULS) method and the ULS curvature method. It was confirmed that the proposed method is more effective for investigating the damage locations of simply supported beams than the two conventional methods in terms of sensitivity to damage under measurement noise. PMID:26501286

  2. Electroencephalographic study showing that tactile stimulation by fabrics of different qualities elicit graded event-related potentials.

    PubMed

    Hoefer, D; Handel, M; Müller, K-M; Hammer, T R

    2016-11-01

    Neurophysiologic data on reactions of the human brain towards tactile stimuli evoked by fabrics moved on the skin are scarce. Furthermore, evaluation of fabrics' pleasantness using questionnaires suffers subjective biases. That is why we used a 64-channel electroencephalography (EEG) to objectively evaluate real-time brain reactions to fabric-skin interactions. Tactile stimuli were triggered by selected fabrics of different qualities, i.e. modal/polyamide single jersey, cotton double rib and a jute fabric, applied hidden to either the palm or forearm of 24 subjects via a custom-made fabric-to-skin applicator called SOFIA. One-way anova analysis was carried out to verify the EEG data. The modal/polyamide fabric applied to the forearm and palm led to slightly stronger emotional valence scores in the brain than the conventional or baseline fabric. Furthermore, the single jersey elicits significant higher event-related potential (ERP) signals in all subjects when applied to the forearm, suggesting less distraction and better cognitive resources during the fabric/skin interaction. The brain thus reacts with instantaneous ERP to tactile stimulation of fabrics and is able to discriminate different qualities via implicit preferences. The test procedure described here may be a tool to evaluate the fabric feel with the exclusion of subjective biases. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Dynamic assessment of reinforced concrete beams repaired with externally bonded FRP sheets

    NASA Astrophysics Data System (ADS)

    Bonfiglioli, B.; Pascale, G.

    2006-01-01

    This research deals with RC beams strengthened with FRP. An experimental research is presented which is aimed at evaluating the capability of an experimental modal analysis to assess the stiffness decrease due to damage, as well as the stiffness recovery due to strengthening. Ten beams were tested. All of them were subjected to loading cycles with increasing load levels in order to induce cracking of different severity in them. The beams were then retrofitted by externally bonded FRP sheets. Three types of composites were used. The number of layers was varied, too. Modal tests were carried out after each loading-unloading cycle. The modal frequencies and damping ratios were determined for the first four vibration modes. The results obtained indicate that an experimental modal analysis can give useful information on the severity of damage and the effectiveness of strengthening.

  4. Keratometric alterations following the 25-gauge transconjunctival sutureless pars plana vitrectomy versus the conventional pars plana vitrectomy.

    PubMed

    Citirik, Mehmet; Batman, Cosar; Bicer, Tolga; Zilelioglu, Orhan

    2009-09-01

    To assess the alterations in keratometric astigmatism following the 25-gauge transconjunctival sutureless pars plana vitrectomy versus the conventional pars plana vitrectomy. Sixteen consecutive patients were enrolled into the study. Conventional vitrectomy was applied to eight of the cases and 25-gauge transconjunctival sutureless vitrectomy was performed in eight patients. Keratometry was performed before and after the surgery. In the 25-gauge transconjunctival sutureless pars plana vitrectomy group, statistically significant changes were not observed in the corneal curvature in any post-operative follow-up measurement (p > 0.05); whereas in the conventional pars plana vitrectomy group, statistically significant changes were observed in the first postoperative day (p = 0.01) and first postoperative month (p = 0.03). We noted that these changes returned to baseline in three months (p = 0.26). Both 25-gauge transconjunctival sutureless and conventional pars plana vitrectomy are effective surgical modalities for selected diseases of the posterior segment. Surgical procedures are critical for the visual rehabilitation of the patients. The post-operative corneal astigmatism of the vitrectomised eyes can be accurately determined at least two months post-operatively.

  5. Quantitative photoacoustic elasticity and viscosity imaging for cirrhosis detection

    NASA Astrophysics Data System (ADS)

    Wang, Qian; Shi, Yujiao; Yang, Fen; Yang, Sihua

    2018-05-01

    Elasticity and viscosity assessments are essential for understanding and characterizing the physiological and pathological states of tissue. In this work, by establishing a photoacoustic (PA) shear wave model, an approach for quantitative PA elasticity imaging based on measurement of the rise time of the thermoelastic displacement was developed. Thus, using an existing PA viscoelasticity imaging method that features a phase delay measurement, quantitative PA elasticity imaging and viscosity imaging can be obtained in a simultaneous manner. The method was tested and validated by imaging viscoelastic agar phantoms prepared at different agar concentrations, and the imaging data were in good agreement with rheometry results. Ex vivo experiments on liver pathological models demonstrated the capability for cirrhosis detection, and the results were consistent with the corresponding histological results. This method expands the scope of conventional PA imaging and has potential to become an important alternative imaging modality.

  6. Diffraction-Enhanced Computed Tomographic Imaging of Growing Piglet Joints by Using a Synchrotron Light Source

    PubMed Central

    Rhoades, Glendon W; Belev, George S; Chapman, L Dean; Wiebe, Sheldon P; Cooper, David M; Wong, Adelaine TF; Rosenberg, Alan M

    2015-01-01

    The objective of this project was to develop and test a new technology for imaging growing joints by means of diffraction-enhanced imaging (DEI) combined with CT and using a synchrotron radiation source. DEI–CT images of an explanted 4-wk-old piglet stifle joint were acquired by using a 40-keV beam. The series of scanned slices was later ‘stitched’ together, forming a 3D dataset. High-resolution DEI-CT images demonstrated fine detail within all joint structures and tissues. Striking detail of vasculature traversing between bone and cartilage, a characteristic of growing but not mature joints, was demonstrated. This report documents for the first time that DEI combined with CT and a synchrotron radiation source can generate more detailed images of intact, growing joints than can currently available conventional imaging modalities. PMID:26310464

  7. [Effects of biphasic spiral CT, conventional and iron oxide enhanced MRI on therapy and therapy costs in patients with focal liver lesions].

    PubMed

    Helmberger, T; Gregor, M; Holzknecht, N; Rau, H; Scheidler, J; Reiser, M

    2000-03-01

    Evaluation of the diagnostic efficacy and cost-benefit of contrast enhanced CT (CT) and MRI pre- and post-SPIO-particles in focal hepatic disease with consideration of therapeutic outcome. In 52 patients with the suspicion of primary or secondary hepatic malignancy, biphasic spiral CT and breath-hold gradient-echo T1- and fast spin-echo T2-weighted MRI pre- and post-iron oxide administration (1.5 T, body-phased-array coil) were compared. The number of hepatic lesions and the related diagnoses resulting from each imaging modality were recorded and statistically correlated to the final diagnoses established by biopsy/OP (34/52), long term follow-up of 12 months (18/52), and a consensus reading of all imaging modalities considering all clinical imaging information. The most likely induced therapy resulting from each imaging test was correlated to the final therapy. Based on data from the hospitals accountants, the therapy-related costs were estimated without hospitalization costs. In 34/52 (65.4%) of the cases the correct diagnosis was primarily stated by CT (sensitivity [se.] 85.2%, specificity [sp.] 44.0%). In additional 10/52 of the cases unenhanced MRI (se. 91.4%, sp. 75.0%) enabled correct diagnoses, and in another 6 cases the diagnosis was established only by SPIO-MRI (se. 100%, sp. 86.7%). Considering the possible therapeutic recommendation arising from each modality, CT would have induced needles therapy costs of 191,042 DM, unenhanced MRI of 171,035 DM, and SPIO-MRI of 7,311 DM. In comparison to the real therapy costs of 221,873 DM, this would have corresponded to an unnecessary increase of therapy costs of 86.1%, 77.1%, and 3.3%, respectively. In two cases (1 hemangioma, 1 regenerative nodule) all modalities failed, causing unnecessary surgery in one patient. In this problem-oriented scenario unenhanced and SPIO-enhanced MRI proved to be superior to CT regarding diagnostic efficacy. The cost-benefit resulted mainly due to preserving patients from unnecessary surgical procedures.

  8. Appraisal of unimodal cues during agonistic interactions in Maylandia zebra

    PubMed Central

    Ben Ammar, Imen; Fernandez, Marie S.A.; Boyer, Nicolas; Attia, Joël; Fonseca, Paulo J.; Amorim, M. Clara P.; Beauchaud, Marilyn

    2017-01-01

    Communication is essential during social interactions including animal conflicts and it is often a complex process involving multiple sensory channels or modalities. To better understand how different modalities interact during communication, it is fundamental to study the behavioural responses to both the composite multimodal signal and each unimodal component with adequate experimental protocols. Here we test how an African cichlid, which communicates with multiple senses, responds to different sensory stimuli in a social relevant scenario. We tested Maylandia zebra males with isolated chemical (urine or holding water coming both from dominant males), visual (real opponent or video playback) and acoustic (agonistic sounds) cues during agonistic interactions. We showed that (1) these fish relied mostly on the visual modality, showing increased aggressiveness in response to the sight of a real contestant but no responses to urine or agonistic sounds presented separately, (2) video playback in our study did not appear appropriate to test the visual modality and needs more technical prospecting, (3) holding water provoked territorial behaviours and seems to be promising for the investigation into the role of the chemical channel in this species. Our findings suggest that unimodal signals are non-redundant but how different sensory modalities interplay during communication remains largely unknown in fish. PMID:28785523

  9. Large-area photogrammetry based testing of wind turbine blades

    NASA Astrophysics Data System (ADS)

    Poozesh, Peyman; Baqersad, Javad; Niezrecki, Christopher; Avitabile, Peter; Harvey, Eric; Yarala, Rahul

    2017-03-01

    An optically based sensing system that can measure the displacement and strain over essentially the entire area of a utility-scale blade leads to a measurement system that can significantly reduce the time and cost associated with traditional instrumentation. This paper evaluates the performance of conventional three dimensional digital image correlation (3D DIC) and three dimensional point tracking (3DPT) approaches over the surface of wind turbine blades and proposes a multi-camera measurement system using dynamic spatial data stitching. The potential advantages for the proposed approach include: (1) full-field measurement distributed over a very large area, (2) the elimination of time-consuming wiring and expensive sensors, and (3) the need for large-channel data acquisition systems. There are several challenges associated with extending the capability of a standard 3D DIC system to measure entire surface of utility scale blades to extract distributed strain, deflection, and modal parameters. This paper only tries to address some of the difficulties including: (1) assessing the accuracy of the 3D DIC system to measure full-field distributed strain and displacement over the large area, (2) understanding the geometrical constraints associated with a wind turbine testing facility (e.g. lighting, working distance, and speckle pattern size), (3) evaluating the performance of the dynamic stitching method to combine two different fields of view by extracting modal parameters from aligned point clouds, and (4) determining the feasibility of employing an output-only system identification to estimate modal parameters of a utility scale wind turbine blade from optically measured data. Within the current work, the results of an optical measurement (one stereo-vision system) performed on a large area over a 50-m utility-scale blade subjected to quasi-static and cyclic loading are presented. The blade certification and testing is typically performed using International Electro-Technical Commission standard (IEC 61400-23). For static tests, the blade is pulled in either flap-wise or edge-wise directions to measure deflection or distributed strain at a few limited locations of a large-sized blade. Additionally, the paper explores the error associated with using a multi-camera system (two stereo-vision systems) in measuring 3D displacement and extracting structural dynamic parameters on a mock set up emulating a utility-scale wind turbine blade. The results obtained in this paper reveal that the multi-camera measurement system has the potential to identify the dynamic characteristics of a very large structure.

  10. The sensory substrate of multimodal communication in brown-headed cowbirds: are females sensory 'specialists' or 'generalists'?

    PubMed

    Ronald, Kelly L; Sesterhenn, Timothy M; Fernandez-Juricic, Esteban; Lucas, Jeffrey R

    2017-11-01

    Many animals communicate with multimodal signals. While we have an understanding of multimodal signal production, we know relatively less about receiver filtering of multimodal signals and whether filtering capacity in one modality influences filtering in a second modality. Most multimodal signals contain a temporal element, such as change in frequency over time or a dynamic visual display. We examined the relationship in temporal resolution across two modalities to test whether females are (1) sensory 'specialists', where a trade-off exists between the sensory modalities, (2) sensory 'generalists', where a positive relationship exists between the modalities, or (3) whether no relationship exists between modalities. We used female brown-headed cowbirds (Molothrus ater) to investigate this question as males court females with an audiovisual display. We found a significant positive relationship between female visual and auditory temporal resolution, suggesting that females are sensory 'generalists'. Females appear to resolve information well across multiple modalities, which may select for males that signal their quality similarly across modalities.

  11. Advanced Gun System (AGS) Dynamic Characterization: Modal Test and Analysis, High-Frequency Analysis.

    DTIC Science & Technology

    1999-12-01

    frequency data (to 10 kHz) in the AGS test. 3.2 High-Frequency Damping Determination by Wavelet Transform. The continuous wavelet transform (CWT...ARMY RESEARCH LABORATORY MmOSm Hi Advanced Gun System ( AGS ) Dynamic Characterization: Modal Test and Analysis, High-Frequency Analysis by Morris...this report when it is no longer needed. Do not return it to the originator. ERRATA SHEET re: ARL-TR-2138 "Advanced Gun System ( AGS ) Dynamic

  12. Hybrid Residual Flexibility/Mass-Additive Method for Structural Dynamic Testing

    NASA Technical Reports Server (NTRS)

    Tinker, M. L.

    2003-01-01

    A large fixture was designed and constructed for modal vibration testing of International Space Station elements. This fixed-base test fixture, which weighs thousands of pounds and is anchored to a massive concrete floor, initially utilized spherical bearings and pendulum mechanisms to simulate Shuttle orbiter boundary constraints for launch of the hardware. Many difficulties were encountered during a checkout test of the common module prototype structure, mainly due to undesirable friction and excessive clearances in the test-article-to-fixture interface bearings. Measured mode shapes and frequencies were not representative of orbiter-constrained modes due to the friction and clearance effects in the bearings. As a result, a major redesign effort for the interface mechanisms was undertaken. The total cost of the fixture design, construction and checkout, and redesign was over $2 million. Because of the problems experienced with fixed-base testing, alternative free-suspension methods were studied, including the residual flexibility and mass-additive approaches. Free-suspension structural dynamics test methods utilize soft elastic bungee cords and overhead frame suspension systems that are less complex and much less expensive than fixed-base systems. The cost of free-suspension fixturing is on the order of tens of thousands of dollars as opposed to millions, for large fixed-base fixturing. In addition, free-suspension test configurations are portable, allowing modal tests to be done at sites without modal test facilities. For example, a mass-additive modal test of the ASTRO-1 Shuttle payload was done at the Kennedy Space Center launch site. In this Technical Memorandum, the mass-additive and residual flexibility test methods are described in detail. A discussion of a hybrid approach that combines the best characteristics of each method follows and is the focus of the study.

  13. Integrating conceptual knowledge within and across representational modalities.

    PubMed

    McNorgan, Chris; Reid, Jackie; McRae, Ken

    2011-02-01

    Research suggests that concepts are distributed across brain regions specialized for processing information from different sensorimotor modalities. Multimodal semantic models fall into one of two broad classes differentiated by the assumed hierarchy of convergence zones over which information is integrated. In shallow models, communication within- and between-modality is accomplished using either direct connectivity, or a central semantic hub. In deep models, modalities are connected via cascading integration sites with successively wider receptive fields. Four experiments provide the first direct behavioral tests of these models using speeded tasks involving feature inference and concept activation. Shallow models predict no within-modal versus cross-modal difference in either task, whereas deep models predict a within-modal advantage for feature inference, but a cross-modal advantage for concept activation. Experiments 1 and 2 used relatedness judgments to tap participants' knowledge of relations for within- and cross-modal feature pairs. Experiments 3 and 4 used a dual-feature verification task. The pattern of decision latencies across Experiments 1-4 is consistent with a deep integration hierarchy. Copyright © 2010 Elsevier B.V. All rights reserved.

  14. System Identification of Mistuned Bladed Disks from Traveling Wave Response Measurements

    NASA Technical Reports Server (NTRS)

    Feiner, D. M.; Griffin, J. H.; Jones, K. W.; Kenyon, J. A.; Mehmed, O.; Kurkov, A. P.

    2003-01-01

    A new approach to modal analysis is presented. By applying this technique to bladed disk system identification methods, one can determine the mistuning in a rotor based on its response to a traveling wave excitation. This allows system identification to be performed under rotating conditions, and thus expands the applicability of existing mistuning identification techniques from integrally bladed rotors to conventional bladed disks.

  15. Rapid impact testing for quantitative assessment of large populations of bridges

    NASA Astrophysics Data System (ADS)

    Zhou, Yun; Prader, John; DeVitis, John; Deal, Adrienne; Zhang, Jian; Moon, Franklin; Aktan, A. Emin

    2011-04-01

    Although the widely acknowledged shortcomings of visual inspection have fueled significant advances in the areas of non-destructive evaluation and structural health monitoring (SHM) over the last several decades, the actual practice of bridge assessment has remained largely unchanged. The authors believe the lack of adoption, especially of SHM technologies, is related to the 'single structure' scenarios that drive most research. To overcome this, the authors have developed a concept for a rapid single-input, multiple-output (SIMO) impact testing device that will be capable of capturing modal parameters and estimating flexibility/deflection basins of common highway bridges during routine inspections. The device is composed of a trailer-mounted impact source (capable of delivering a 50 kip impact) and retractable sensor arms, and will be controlled by an automated data acquisition, processing and modal parameter estimation software. The research presented in this paper covers (a) the theoretical basis for SISO, SIMO and MIMO impact testing to estimate flexibility, (b) proof of concept numerical studies using a finite element model, and (c) a pilot implementation on an operating highway bridge. Results indicate that the proposed approach can estimate modal flexibility within a few percent of static flexibility; however, the estimated modal flexibility matrix is only reliable for the substructures associated with the various SIMO tests. To overcome this shortcoming, a modal 'stitching' approach for substructure integration to estimate the full Eigen vector matrix is developed, and preliminary results of these methods are also presented.

  16. Clinical management of achalasia: current state of the art

    PubMed Central

    Krill, Joseph T; Naik, Rishi D; Vaezi, Michael F

    2016-01-01

    Achalasia is a primary disorder of esophageal motility. It classically presents with dysphagia to both solids and liquids but may be accompanied by regurgitation and chest pain. The gold standard for the diagnosis of achalasia is esophageal motility testing with manometry, which often reveals aperistalsis of the esophageal body and incomplete lower esophageal sphincter relaxation. The diagnosis is aided by complimentary tests, such as esophagogastroduodenoscopy and contrast radiography. Esophagogastroduodenoscopy is indicated to rule out mimickers of the disease known as “pseudoachalasia” (eg, malignancy). Endoscopic appearance of a dilated esophagus with retained food or saliva and a puckered lower esophageal sphincter should raise suspicion for achalasia. Additionally, barium esophagography may reveal a dilated esophagus with a distal tapering giving it a “bird’s beak” appearance. Multiple therapeutic modalities aid in the management of achalasia, the decision of which depends on operative risk factors. Conventional treatments include medical therapy, botulinum toxin injection, pneumatic dilation, and Heller myotomy. The last two are defined as the most definitive treatment options. New emerging therapies include peroral endoscopic myotomy, placement of self-expanding metallic stents, and endoscopic sclerotherapy. PMID:27110134

  17. Application of optical interferometric techniques for non-destructive evaluation of novel "green" composite materials

    NASA Astrophysics Data System (ADS)

    Pagliarulo, Vito; Russo, Pietro; Bianco, Vittorio; Ferraro, Pietro; Simeoli, Giorgio; Cimino, Francesca; Ruggiero, Berardo

    2018-04-01

    Nowadays the use of advanced composite materials in aeronautics, both civil and military, in automotive and in sport applications, citing some, is well established. The characteristics of composite materials in terms of weight, fatigue resistance and corrosion resistance make them competitive with respect to conventional ones. On the other side, the fabrication process of the most employed composites reinforced by carbon fibers or glass fibers, needs of complex steps that not always are environmental complaisant. Moreover, such fibers are not themselves "green". For these reasons, in the last decades, the use of natural reinforcing fibers has gained an increasing attention allowing the development of new materials with the same advantages of composite systems but respecting the environment. Furthermore, such materials for their structural complexity are not always compatible with the use of standard non-destructive evaluation as the ultrasounds methods. In this work the efficiency of the employment of optical interferometric techniques as nondestructive evaluation methods in full field modality is proved on novel "green" composite materials. In particular, Electronic Speckle Pattern Interferometry has been tested on different kinds of specimens after flexural tests.

  18. Modal Analysis of MARS Solar Panel and Planar Vibrations

    NASA Technical Reports Server (NTRS)

    Simonyan, Andranik; Williams, R. Brett

    2007-01-01

    This slide presentation reviews the modal analysis of MARS solar panels and the planar vibrations. Included are views of the solar panels mock-up assembly, a view of the test seup,a view of the plot from the test, with the raw numbers of the frequencies in Hz values with the mode number, the spatial acceleration plots of Center sub panel at resonant frequencies, predictions from the Finite element models, an explanation of the two test that were done on the plate and the results from both tests,

  19. Modal Test of Six-Meter Hypersonic Inflatable Aerodynamic Decelerator

    NASA Technical Reports Server (NTRS)

    Abraham, Nijo; Buehrle, Ralph; Templeton, Justin; Lindell, Mike; Hancock, Sean M.

    2014-01-01

    A modal test was performed on the six-meter Hypersonic Inflatable Aerodynamic Decelerator (HIAD) test article to gain a firm understanding of the dynamic characteristics of the unloaded structure within the low frequency range. The tests involved various configurations of the HIAD to understand the influence of the tri-torus, the varying pressure within the toroids and the influence of straps. The primary test was conducted utilizing an eletrodynamic shaker and the results were verified using a step relaxation technique. The analysis results show an increase in the structure's stiffness with respect to increasing pressure. The results also show the rise of coupled modes with the tri-torus configurations. During the testing activity, the attached straps exhibited a behavior that is similar to that described as fuzzy structures in the literature. Therefore extensive tests were also performed by utilizing foam to mitigate these effects as well as understand the modal parameters of these fuzzy sub structures. Results are being utilized to update the finite element model of the six-meter HIAD and to gain a better understanding of the modeling of complex inflatable structures.

  20. Dynamic testing of a two-dimensional box truss beam

    NASA Technical Reports Server (NTRS)

    White, Charles W.

    1987-01-01

    Testing to determine the effects of joint freeplay and pretensioning of diagonal members on the dynamic characteristics of a two-dimensional box truss beam was conducted. The test article was ten bays of planar truss suspended by long wires at each joint. Each bay measured 2 meters per side. Pins of varying size were used to simulate various joint freeplay conditions. Single-point random excitation was the primary method of test. The rational fraction polynomial method was used to extract modal characteristics from test data. A finite element model of the test article was generated from which modal characteristics were predicted. These were compared with those obtained from tests. With the exception of the fundamental mode, correlation of theoretical and experimental results was poor, caused by the resonant coupling of local truss member bending modes with global truss beam modes. This coupling introduced many modes in the frequency range of interest whose frequencies were sensitive to joint boundary conditions. It was concluded that local/global coupling must be avoided in the frequency range where accurate modal characteristics are required.

  1. Comparison of balance assessment modalities in emergency department elders: a pilot cross-sectional observational study.

    PubMed

    Caterino, Jeffrey M; Karaman, Rowan; Arora, Vinay; Martin, Jacqueline L; Hiestand, Brian C

    2009-09-28

    More than one-third of US adults 65 and over fall every year. These falls may cause serious injury including substantial long-term morbidity (due declines in activities of daily living) and death. The emergency department (ED) visit represents an opportunity for identifying high risk elders and potentially instituting falls-related interventions. The unique characteristic of the ED environment and patient population necessitate that risk-assessment modalities be validated in this specific setting. In order to better identify elders at risk of falls, we examined the relationship between patient-provided history of falling and two testing modalities (a balance plate system and the timed up-and-go [TUG] test) in elder emergency department (ED) patients. We conducted a cross-sectional observational study of patients > or = 60 years old being discharged from the ED. Patient history of falls in the past week, month, 6 months, and year was obtained. Balance plate center of pressure excursion (COP) measurements and TUG testing times were recorded. COP was recorded under four conditions: normal stability eyes open (NSEO) and closed (NSEC), and perturbed stability eyes open and closed. Correlation between TUG and COP scores was measured. Univariate logistic regression was used to identify the relationship between patient-provided falls history and the two testing modalities. Proportions, likelihood ratios, and receiver-operating-characteristic (ROC) curves for prediction of previous falls were reported. Fifty-three subjects were enrolled, 11% had fallen in the previous week and 42% in the previous year. There was no correlation between TUG and any balance plate measurements. In logistic regression, neither testing modality was associated with prior history of falls (p > 0.05 for all time periods). Balance plate NSEO and NSEC testing cutoffs could be identified which were 83% sensitive and had a negative likelihood ratio (LR-) of 0.3 for falls in the past week. TUG testing was not useful for falls in the past week, but performed best for more distant falls in the past month, 6 months, or year. TUG cutoffs with sensitivity over 80% and LR(-) of 0.17-0.32 could be identified for these time periods. Over 40% of community-dwelling elder ED patients report a fall within the past year. Balance plate and TUG testing were feasibly conducted in an ED setting. There is no relationship between scores on balance plate and TUG testing in these patients. In regression analysis, neither modality was significantly associated with patient provided history of falls. These modalities should not be adopted for screening purposes in elders in the ED setting without validation in future studies or as part of multi-factorial risk assessment.

  2. A Benchmark Problem for Development of Autonomous Structural Modal Identification

    NASA Technical Reports Server (NTRS)

    Pappa, Richard S.; Woodard, Stanley E.; Juang, Jer-Nan

    1996-01-01

    This paper summarizes modal identification results obtained using an autonomous version of the Eigensystem Realization Algorithm on a dynamically complex, laboratory structure. The benchmark problem uses 48 of 768 free-decay responses measured in a complete modal survey test. The true modal parameters of the structure are well known from two previous, independent investigations. Without user involvement, the autonomous data analysis identified 24 to 33 structural modes with good to excellent accuracy in 62 seconds of CPU time (on a DEC Alpha 4000 computer). The modal identification technique described in the paper is the baseline algorithm for NASA's Autonomous Dynamics Determination (ADD) experiment scheduled to fly on International Space Station assembly flights in 1997-1999.

  3. Incorporating digital imaging into dental hygiene practice.

    PubMed

    Saxe, M J; West, D J

    1997-01-01

    The objective of this paper is to describe digital imaging technology: available modalities, scientific imaging process, advantages and limitations, and applications to dental hygiene practice. Advances in technology have created innovative imaging modalities for intraoral radiography that eliminate film as the traditional image receptor. Digital imaging generates instantaneous radiographic images on a display monitor following exposure. Advantages include lower patient exposure per image and elimination of film processing. Digital imaging enhances diagnostic capabilities and, therefore, treatment decisions by the oral healthcare provider. Utilization of digital imaging technology for intraoral radiography will advance the practice of dental hygiene. Although spatial resolution is inferior to conventional film, digital imaging provides adequate resolution to diagnose oral diseases. Dental hygienists must evaluate new technologies in radiography to continue providing quality care while reducing patient exposure to ionizing radiation.

  4. Modal, ray, and beam techniques for analyzing the EM scattering by open-ended waveguide cavities

    NASA Technical Reports Server (NTRS)

    Pathak, Prabhakar H.; Burkholder, Robert J.

    1989-01-01

    The problem of high-frequency electromagnetic (EM) scattering by open-ended waveguide cavities with an interior termination is analyzed via three different approaches. When cavities can be adequately modeled by joining together piecewise separable waveguide sections, a hybrid combination of asymptotic high-frequency and modal techniques is employed. In the case of more arbitrarily shaped waveguide cavities for which modes cannot even be defined in the conventional sense, the geometrical optics ray approach proves to be highly useful. However, at sufficiently high frequencies, both of these approaches tend to become inefficient. Hence, a paraxial Gaussian batch technique, which retains much of the simplicity of the ray approximation but is potentially more efficient, is investigated. Typical numerical results based on the different approaches are discussed.

  5. Multimodality Imaging in Patients with Secondary Hypertension: With a Focus on Appropriate Imaging Approaches Depending on the Etiologies.

    PubMed

    Ahn, Hyungwoo; Chun, Eun Ju; Lee, Hak Jong; Hwang, Sung Il; Choi, Dong-Ju; Chae, In-Ho; Lee, Kyung Won

    2018-01-01

    Although the causes of hypertension are usually unknown, about 10% of the cases occur secondary to specific etiologies, which are often treatable. Common categories of secondary hypertension include renal parenchymal disease, renovascular stenosis, vascular and endocrinologic disorders. For diseases involving the renal parenchyma and adrenal glands, ultrasonography (US), computed tomography (CT) or magnetic resonance (MR) imaging is recommended. For renovascular stenosis and vascular disorders, Doppler US, conventional or noninvasive (CT or MR) angiography is an appropriate modality. Nuclear imaging can be useful in the differential diagnosis of endocrine causes. Radiologists should understand the role of each imaging modality and its typical findings in various causes of secondary hypertension. This article focuses on appropriate imaging approaches in accordance with the categorized etiologies leading to hypertension.

  6. Fundamental-mode MMF transmission enabled by mode conversion

    NASA Astrophysics Data System (ADS)

    Wu, Zhongying; Li, Juhao; Tian, Yu; Ge, Dawei; Zhu, Jinglong; Ren, Fang; Mo, Qi; Yu, Jinyi; Li, Zhengbin; Chen, Zhangyuan; He, Yongqi

    2018-03-01

    Modal dispersion in conventional multi-mode fiber (MMF) will cause serious signal degradation and an effective solution is to restrict the signal transmission in the fundamental mode of MMF. In this paper, unlike previous methods by filtering out higher-order modes, we propose to adopt low-modal-crosstalk mode converters to realize fundamental-mode MMF transmission. We design and fabricate all-fiber mode-selective couplers (MSC), which perform mode conversion between the fundamental mode in single-mode fiber (SMF) and fundamental mode in MMF. The proposed scheme is experimentally compared with center launching method under different MMF links and then its wavelength division multiplexing (WDM) transmission performance is investigated. Experimental results indicate that the proposed mode conversion scheme could achieve better transmission performance and works well for the whole C-band.

  7. Multi-modal classification of neurodegenerative disease by progressive graph-based transductive learning

    PubMed Central

    Wang, Zhengxia; Zhu, Xiaofeng; Adeli, Ehsan; Zhu, Yingying; Nie, Feiping; Munsell, Brent

    2018-01-01

    Graph-based transductive learning (GTL) is a powerful machine learning technique that is used when sufficient training data is not available. In particular, conventional GTL approaches first construct a fixed inter-subject relation graph that is based on similarities in voxel intensity values in the feature domain, which can then be used to propagate the known phenotype data (i.e., clinical scores and labels) from the training data to the testing data in the label domain. However, this type of graph is exclusively learned in the feature domain, and primarily due to outliers in the observed features, may not be optimal for label propagation in the label domain. To address this limitation, a progressive GTL (pGTL) method is proposed that gradually finds an intrinsic data representation that more accurately aligns imaging features with the phenotype data. In general, optimal feature-to-phenotype alignment is achieved using an iterative approach that: (1) refines inter-subject relationships observed in the feature domain by using the learned intrinsic data representation in the label domain, (2) updates the intrinsic data representation from the refined inter-subject relationships, and (3) verifies the intrinsic data representation on the training data to guarantee an optimal classification when applied to testing data. Additionally, the iterative approach is extended to multi-modal imaging data to further improve pGTL classification accuracy. Using Alzheimer’s disease and Parkinson’s disease study data, the classification accuracy of the proposed pGTL method is compared to several state-of-the-art classification methods, and the results show pGTL can more accurately identify subjects, even at different progression stages, in these two study data sets. PMID:28551556

  8. The effect of exercise therapy on knee osteoarthritis: a randomized clinical trial

    PubMed Central

    Nejati, Parisa; Farzinmehr, Azizeh; Moradi-Lakeh, Maziar

    2015-01-01

    Background: Knee osteoarthritis (OA) is the most common musculoskeletal disease among old individuals which affects ability for sitting on the chair, standing, walking and climbing stairs. Our objective was to investigate the short and long-term effects of the most simple and the least expensive exercise protocols in combination to conventional conservative therapy for knee OA. Methods: It was a single blind RCT study with a 12-months follow-up. Totally, 56 patients with knee OA were assigned into 2 random groups. The patients in exercise group received exercise for knee muscles in combination with non-steroid anti-inflammatory drugs (NSAIDs) and 10 sessions acupuncture and physiotherapy modalities. Non-exercise group received similar treatments except exercise program. The changes in patients’ pain and functional status were evaluated by visual analog scale (VAS), knee and osteoarthritis outcome score (KOOS) questionnaire and functional tests (4 steps, 5 sit up, and 6 min walk test) before and after treatment (1 and 3 months after intervention), and 1 year later at the follow-up. Results: The results showed that the patients with knee OA in exercise group had significant improvement in pain, disability, walking, stair climbing, and sit up speed after treatment at first and second follow-up when compared with their initial status and when compared with non-exercise group. At third follow up (1 year later) there was significant difference between groups in VAS and in three items of KOOS questionnaire in functional status. Conclusion: Non aerobic exercises for muscles around knee can augment the effect of other therapeutic interventions like medical therapy, acupuncture, and modalities for knee OA. PMID:26034739

  9. Diagnostic performance of 3D standing CT imaging for detection of knee osteoarthritis features.

    PubMed

    Segal, Neil A; Nevitt, Michael C; Lynch, John A; Niu, Jingbo; Torner, James C; Guermazi, Ali

    2015-07-01

    To determine the diagnostic performance of standing computerized tomography (SCT) of the knee for osteophytes and subchondral cysts compared with fixed-flexion radiography, using MRI as the reference standard. Twenty participants were recruited from the Multicenter Osteoarthritis Study. Participants' knees were imaged with SCT while standing in a knee-positioning frame, and with postero-anterior fixed-flexion radiography and 1T MRI. Medial and lateral marginal osteophytes and subchondral cysts were scored on bilateral radiographs and coronal SCT images using the OARSI grading system and on coronal MRI using Whole Organ MRI Scoring. Imaging modalities were read separately with images in random order. Sensitivity, specificity and accuracy for the detection of lesions were calculated and differences between modalities were tested using McNemar's test. Participants' mean age was 66.8 years, body mass index was 29.6 kg/m(2) and 50% were women. Of the 160 surfaces (medial and lateral femur and tibia for 40 knees), MRI revealed 84 osteophytes and 10 subchondral cysts. In comparison with osteophytes and subchondral cysts detected by MRI, SCT was significantly more sensitive (93 and 100%; p < 0.004) and accurate (95 and 99%; p < 0.001 for osteophytes) than plain radiographs (sensitivity 60 and 10% and accuracy 79 and 94%, respectively). For osteophytes, differences in sensitivity and accuracy were greatest at the medial femur (p = 0.002). In comparison with MRI, SCT imaging was more sensitive and accurate for detection of osteophytes and subchondral cysts than conventional fixed-flexion radiography. Additional study is warranted to assess diagnostic performance of SCT measures of joint space width, progression of OA features and the patellofemoral joint.

  10. Dermatological Feasibility of Multimodal Facial Color Imaging Modality for Cross-Evaluation of Facial Actinic Keratosis

    PubMed Central

    Bae, Youngwoo; Son, Taeyoon; Nelson, J. Stuart; Kim, Jae-Hong; Choi, Eung Ho; Jung, Byungjo

    2010-01-01

    Background/Purpose Digital color image analysis is currently considered as a routine procedure in dermatology. In our previous study, a multimodal facial color imaging modality (MFCIM), which provides a conventional, parallel- and cross-polarization, and fluorescent color image, was introduced for objective evaluation of various facial skin lesions. This study introduces a commercial version of MFCIM, DermaVision-PRO, for routine clinical use in dermatology and demonstrates its dermatological feasibility for cross-evaluation of skin lesions. Methods/Results Sample images of subjects with actinic keratosis or non-melanoma skin cancers were obtained at four different imaging modes. Various image analysis methods were applied to cross-evaluate the skin lesion and, finally, extract valuable diagnostic information. DermaVision-PRO is potentially a useful tool as an objective macroscopic imaging modality for quick prescreening and cross-evaluation of facial skin lesions. Conclusion DermaVision-PRO may be utilized as a useful tool for cross-evaluation of widely distributed facial skin lesions and an efficient database management of patient information. PMID:20923462

  11. Microvascular anastomosis guidance and evaluation using real-time three-dimensional Fourier-domain Doppler optical coherence tomography

    PubMed Central

    Ibrahim, Zuhaib; Tong, Dedi; Zhu, Shan; Mao, Qi; Pang, John; Andrew Lee, Wei Ping; Brandacher, Gerald; Kang, Jin U.

    2013-01-01

    Abstract. Vascular and microvascular anastomoses are critical components of reconstructive microsurgery, vascular surgery, and transplant surgery. Intraoperative surgical guidance using a surgical imaging modality that provides an in-depth view and three-dimensional (3-D) imaging can potentially improve outcome following both conventional and innovative anastomosis techniques. Objective postoperative imaging of the anastomosed vessel can potentially improve the salvage rate when combined with other clinical assessment tools, such as capillary refill, temperature, blanching, and skin turgor. Compared to other contemporary postoperative monitoring modalities—computed tomography angiograms, magnetic resonance (MR) angiograms, and ultrasound Doppler—optical coherence tomography (OCT) is a noninvasive high-resolution (micron-level), high-speed, 3-D imaging modality that has been adopted widely in biomedical and clinical applications. For the first time, to the best of our knowledge, the feasibility of real-time 3-D phase-resolved Doppler OCT (PRDOCT) as an assisted intra- and postoperative imaging modality for microvascular anastomosis of rodent femoral vessels is demonstrated, which will provide new insights and a potential breakthrough to microvascular and supermicrovascular surgery. PMID:23856833

  12. A Dual-Modality System for Both Multi-Color Ultrasound-Switchable Fluorescence and Ultrasound Imaging

    PubMed Central

    Kandukuri, Jayanth; Yu, Shuai; Cheng, Bingbing; Bandi, Venugopal; D’Souza, Francis; Nguyen, Kytai T.; Hong, Yi; Yuan, Baohong

    2017-01-01

    Simultaneous imaging of multiple targets (SIMT) in opaque biological tissues is an important goal for molecular imaging in the future. Multi-color fluorescence imaging in deep tissues is a promising technology to reach this goal. In this work, we developed a dual-modality imaging system by combining our recently developed ultrasound-switchable fluorescence (USF) imaging technology with the conventional ultrasound (US) B-mode imaging. This dual-modality system can simultaneously image tissue acoustic structure information and multi-color fluorophores in centimeter-deep tissue with comparable spatial resolutions. To conduct USF imaging on the same plane (i.e., x-z plane) as US imaging, we adopted two 90°-crossed ultrasound transducers with an overlapped focal region, while the US transducer (the third one) was positioned at the center of these two USF transducers. Thus, the axial resolution of USF is close to the lateral resolution, which allows a point-by-point USF scanning on the same plane as the US imaging. Both multi-color USF and ultrasound imaging of a tissue phantom were demonstrated. PMID:28165390

  13. Communication modality sampling for a toddler with Angelman syndrome.

    PubMed

    Hyppa Martin, Jolene; Reichle, Joe; Dimian, Adele; Chen, Mo

    2013-10-01

    Vocal, gestural, and graphic communication modes were implemented concurrently with a toddler with Angelman syndrome to identify the most efficiently learned communication mode to emphasize in an initial augmentative communication system. Symbols representing preferred objects were introduced in vocal, gestural, and graphic communication modes using an alternating treatment single-subject experimental design. Conventionally accepted prompting strategies were used to teach symbols in each communication mode. Because the learner did not vocally imitate, vocal mode intervention focused on increasing vocal frequency as an initial step. When graphic and gestural mode performances were compared, the learner most accurately produced requests in graphic mode (percentage of nonoverlapping data = 96). Given the lack of success in prompting vocal productions, a comparison between vocal and the other two communication modes was not made. A growing body of evidence suggests that concurrent modality sampling is a promising low-inference, data-driven procedure that can be used to inform selection of a communication mode(s) for initial emphasis with young children. Concurrent modality sampling can guide clinical decisions regarding the allocation of treatment resources to promote success in building an initial communicative repertoire.

  14. Comparison of on-road emissions for hybrid and regular transit buses.

    PubMed

    Hallmark, Shauna L; Wang, Bo; Sperry, Robert

    2013-10-01

    Hybrid technology offers an attractive option for transit buses, since it has the potential to significantly reduce operating costs for transit agencies. The main impetus behind use of hybrid transit vehicles is fuel savings and reduced emissions. Laboratory tests have indicated that hybrid transit buses can have significantly lower emissions compared with conventional transit buses. However the number of studies is limited and laboratory tests may not represent actual driving conditions, since in-use vehicle operation differs from laboratory test cycles. This paper describes an on-road evaluation of in-use emission differences between hybrid-electric and conventional transit buses for the Ames, Iowa transit authority, CyRide. Emissions were collected on-road using a portable emissions monitoring system (PEMS) for three hybrid and two control buses. Emissions were collected for at least one operating bus day. Each bus was evaluated over the same route pattern, which utilizes the same driver. The number of passengers embarking or disembarking at each stop was collected by an on-board data collector so that passenger load could be included. Vehicle emissions are correlated to engine load demand, which is a function of factors such as vehicle load, speed, and acceleration. PEMS data are provided second by second and vehicle-specific power (VSP) was calculated for each row of data. Instantaneous data were stratified into the defined VSP bins and then average modal emission rates and standard errors were calculated for each bus for each pollutant. Pollutants were then compared by bus type. Carbon dioxide, carbon monoxide, and hydrocarbon emissions were higher for the regular buses across most VSP bins than for the hybrid buses. Nitrogen oxide emissions were unexpectedly higher for the hybrid buses than for the control buses.

  15. Comparison of Two Acoustic Waveguide Methods for Determining Liner Impedance

    NASA Technical Reports Server (NTRS)

    Jones, Michael G.; Watson, Willie R.; Tracy, Maureen B.; Parrott, Tony L.

    2001-01-01

    Acoustic measurements taken in a flow impedance tube are used to assess the relative accuracy of two waveguide methods for impedance eduction in the presence of grazing flow. The aeroacoustic environment is assumed to contain forward and backward-traveling acoustic waves, consisting of multiple modes, and uniform mean flow. Both methods require a measurement of the complex acoustic pressure profile over the length of the test liner. The Single Mode Method assumes that the sound pressure level and phase decay-rates of a single progressive mode can be extracted from this measured complex acoustic pressure profile. No a priori assumptions are made in the Finite Element. Method regarding the modal or reflection content in the measured acoustic pressure profile. The integrity of each method is initially demonstrated by how well their no-flow impedances match those acquired in a normal incidence impedance tube. These tests were conducted using ceramic tubular and conventional perforate liners. Ceramic tubular liners were included because of their impedance insensitivity to mean flow effects. Conversely, the conventional perforate liner was included because its impedance is known to be sensitive to mean flow velocity effects. Excellent comparisons between impedance values educed with the two waveguide methods in the absence of mean flow and the corresponding values educed with the normal incident impedance tube were observed. The two methods are then compared for mean flow Mach numbers up to 0.5, and are shown to give consistent results for both types of test liners. The quality of the results indicates that the Single Mode Method should be used when the measured acoustic pressure profile is clearly dominated by a single progressive mode, and the Finite Element Method should be used for all other cases.

  16. Modal Analysis with the Mobile Modal Testing Unit

    NASA Technical Reports Server (NTRS)

    Wilder, Andrew J.

    2013-01-01

    Recently, National Aeronautics and Space Administration's (NASA's) White Sands Test Facility (WSTF) has tested rocket engines with high pulse frequencies. This has resulted in the use of some of WSTF's existing thrust stands, which were designed for static loading, in tests with large dynamic forces. In order to ensure that the thrust stands can withstand the dynamic loading of high pulse frequency engines while still accurately reporting the test data, their vibrational modes must be characterized. If it is found that they have vibrational modes with frequencies near the pulsing frequency of the test, then they must be modified to withstand the dynamic forces from the pulsing rocket engines. To make this determination the Mobile Modal Testing Unit (MMTU), a system capable of determining the resonant frequencies and mode shapes of a structure, was used on the test stands at WSTF. Once the resonant frequency has been determined for a test stand, it can be compared to the pulse frequency of a test engine to determine whether or not that stand can avoid resonance and reliably test that engine. After analysis of test stand 406 at White Sands Test Facility, it was determined that natural frequencies for the structure are located around 75, 125, and 240 Hz, and thus should be avoided during testing.

  17. Simulation Analysis of Helicopter Ground Resonance Nonlinear Dynamics

    NASA Astrophysics Data System (ADS)

    Zhu, Yan; Lu, Yu-hui; Ling, Ai-min

    2017-07-01

    In order to accurately predict the dynamic instability of helicopter ground resonance, a modeling and simulation method of helicopter ground resonance considering nonlinear dynamic characteristics of components (rotor lead-lag damper, landing gear wheel and absorber) is presented. The numerical integral method is used to calculate the transient responses of the body and rotor, simulating some disturbance. To obtain quantitative instabilities, Fast Fourier Transform (FFT) is conducted to estimate the modal frequencies, and the mobile rectangular window method is employed in the predictions of the modal damping in terms of the response time history. Simulation results show that ground resonance simulation test can exactly lead up the blade lead-lag regressing mode frequency, and the modal damping obtained according to attenuation curves are close to the test results. The simulation test results are in accordance with the actual accident situation, and prove the correctness of the simulation method. This analysis method used for ground resonance simulation test can give out the results according with real helicopter engineering tests.

  18. Colorectal Cancer Screening: Stool DNA and Other Noninvasive Modalities.

    PubMed

    Bailey, James R; Aggarwal, Ashish; Imperiale, Thomas F

    2016-03-01

    Colorectal cancer screening dates to the discovery of precancerous adenomatous tissue. Screening modalities and guidelines directed at prevention and early detection have evolved and resulted in a significant decrease in the prevalence and mortality of colorectal cancer via direct visualization or using specific markers. Despite continued efforts and an overall reduction in deaths attributed to colorectal cancer over the last 25 years, colorectal cancer remains one of the most common causes of malignancy-associated deaths. In attempt to further reduce the prevalence of colorectal cancer and associated deaths, continued improvement in screening quality and adherence remains key. Noninvasive screening modalities are actively being explored. Identification of specific genetic alterations in the adenoma-cancer sequence allow for the study and development of noninvasive screening modalities beyond guaiac-based fecal occult blood testing which target specific alterations or a panel of alterations. The stool DNA test is the first noninvasive screening tool that targets both human hemoglobin and specific genetic alterations. In this review we discuss stool DNA and other commercially available noninvasive colorectal cancer screening modalities in addition to other targets which previously have been or are currently under study.

  19. Cross-modal individual recognition in wild African lions.

    PubMed

    Gilfillan, Geoffrey; Vitale, Jessica; McNutt, John Weldon; McComb, Karen

    2016-08-01

    Individual recognition is considered to have been fundamental in the evolution of complex social systems and is thought to be a widespread ability throughout the animal kingdom. Although robust evidence for individual recognition remains limited, recent experimental paradigms that examine cross-modal processing have demonstrated individual recognition in a range of captive non-human animals. It is now highly relevant to test whether cross-modal individual recognition exists within wild populations and thus examine how it is employed during natural social interactions. We address this question by testing audio-visual cross-modal individual recognition in wild African lions (Panthera leo) using an expectancy-violation paradigm. When presented with a scenario where the playback of a loud-call (roaring) broadcast from behind a visual block is incongruent with the conspecific previously seen there, subjects responded more strongly than during the congruent scenario where the call and individual matched. These findings suggest that lions are capable of audio-visual cross-modal individual recognition and provide a useful method for studying this ability in wild populations. © 2016 The Author(s).

  20. Modal testing of a rotating wind turbine

    NASA Astrophysics Data System (ADS)

    Carne, T. G.; Nord, A. R.

    1982-11-01

    A testing technique was developed to measure the modes of vibration of a rotating vertical-axis wind turbine. This technique was applied to the Sandia Two-Meter Turbine, where the changes in individual modal frequencies as a function of the rotational speed were tracked from 0 rpm (parked) to 600 rpm. During rotational testing, the structural response was measured using a combination of strain gages and accelerometers, passing the signals through slip rings. Excitation of the turbine structure was provided by a scheme which suddenly released a pretensioned cable, thus plucking the turbine as it was rotating at a set speed. In addition to calculating the real modes of the parked turbine, the modes of the rotating turbine were also determined at several rotational speeds. The modes of the rotating system proved to be complex due to centrifugal and Coriolis effects. The modal data for the parked turbine were used to update a finite-element model. Also, the measured modal parameters for the rotating turbine were compared to the analytical results, thus verifying the analytical procedures used to incorporate the effects of the rotating coordinate system.

  1. Health consumption in Sami speaking municipalities and a control group with regard to medical imaging.

    PubMed

    Størmer, Jan; Norum, Jan; Olsen, Lena Ringstad; Eldevik, Petter; Broderstad, Ann Ragnhild

    2012-03-23

    The Northern Norway Regional Health Authority trust aims to offer a high quality specialist health care to all inhabitants. The objective of this study was to document the consumption of medical imaging [conventional radiography (CR), computerised tomography (CT), magnetic resonance (MR), ultrasound (US)]. The eight municipalities in northern Norway included in the administration area of the Sami language law (Sami group - 132,490 persons/year in the period 2003-2009, mean/year 19,363 inhabitants) were matched with a control group of 11 municipalities (non-Sami group - 135,539 persons/year, mean/year 18,927 inhabitants). Population data was accessed from Statistics Norway. Data on imaging exams were derived from a regional database including production data from all public and private institutions within the region. All four main modality groups (CR, CT, MR, US) were analysed. Variations for imaging frequency on each modality were compared between the Sami and non-Sami municipalities. A total of 278,832 exams were performed during study period. The age adjusted exam rate (all modalities) was significantly higher (p < 0.001) in non-Sami (females and males) group. There was no difference with regard to conventional radiography (CR) (p = 0.855). Whereas MR (p < 0.001) imaging was more common in the Sami group, CT (p < 0.001) and US (p = 0.003) exams were more frequently used in the control group. People living in Sami speaking communities experienced significantly less CT and US exams, but had more MR exams than the control group. A relatively high physical activity, obesity and a lower risk of cancer may be explanations.

  2. Health consumption in Sami speaking municipalities and a control group with regard to medical imaging.

    PubMed

    Størmer, Jan; Norum, Jan; Olsen, LenaRingstad; Eldevik, Petter; Ragnhild Broderstad, Ann

    2012-01-01

    The Northern Norway Regional Health Authority trust aims to offer a high quality specialist health care to all inhabitants. The objective of this study was to document the consumption of medical imaging [conventional radiography (CR), computerised tomography (CT), magnetic resonance (MR), ultrasound (US)]. The eight municipalities in northern Norway included in the administration area of the Sami language law (Sami group - 132,490 persons/year in the period 2003-2009, mean/year 19,363 inhabitants) were matched with a control group of 11 municipalities (non-Sami group - 135,539 persons/year, mean/year 18,927 inhabitants). Population data was accessed from Statistics Norway. Data on imaging exams were derived from a regional database including production data from all public and private institutions within the region. All four main modality groups (CR, CT, MR, US) were analysed. Variations for imaging frequency on each modality were compared between the Sami and non-Sami municipalities. A total of 278,832 exams were performed during study period. The age adjusted exam rate (all modalities) was significantly higher (p < 0.001) in non-Sami (females and males) group. There was no difference with regard to conventional radiography (CR) (p = 0.855). Whereas MR (p < 0.001) imaging was more common in the Sami group, CT (p < 0.001) and US (p = 0.003) exams were more frequently used in the control group. People living in Sami speaking communities experienced significantly less CT and US exams, but had more MR exams than the control group. A relatively high physical activity, obesity and a lower risk of cancer may be explanations.

  3. Health consumption in Sami speaking municipalities and a control group with regard to medical imaging

    PubMed Central

    Størmer, Jan; Norum, Jan; Olsen, Lena Ringstad; Eldevik, Petter; Broderstad, Ann Ragnhild

    2012-01-01

    Objectives The Northern Norway Regional Health Authority trust aims to offer a high quality specialist health care to all inhabitants. The objective of this study was to document the consumption of medical imaging [conventional radiography (CR), computerised tomography (CT), magnetic resonance (MR), ultrasound (US)]. Methods The eight municipalities in northern Norway included in the administration area of the Sami language law (Sami group – 132,490 persons/year in the period 2003–2009, mean/year 19,363 inhabitants) were matched with a control group of 11 municipalities (non-Sami group – 135,539 persons/year, mean/year 18,927 inhabitants). Population data was accessed from Statistics Norway. Data on imaging exams were derived from a regional database including production data from all public and private institutions within the region. All four main modality groups (CR, CT, MR, US) were analysed. Variations for imaging frequency on each modality were compared between the Sami and non-Sami municipalities. Results A total of 278,832 exams were performed during study period. The age adjusted exam rate (all modalities) was significantly higher (p <0.001) in non-Sami (females and males) group. There was no difference with regard to conventional radiography (CR) (p=0.855). Whereas MR (p<0.001) imaging was more common in the Sami group, CT (p<0.001) and US (p=0.003) exams were more frequently used in the control group. Conclusion People living in Sami speaking communities experienced significantly less CT and US exams, but had more MR exams than the control group. A relatively high physical activity, obesity and a lower risk of cancer may be explanations. PMID:22456037

  4. Utility of conventional transbronchial needle aspiration with rapid on-site evaluation (c-TBNA-ROSE) at a tertiary care center with endobronchial ultrasound (EBUS) facility

    PubMed Central

    Madan, Neha Kawatra; Madan, Karan; Jain, Deepali; Walia, Ritika; Mohan, Anant; Hadda, Vijay; Mathur, Sandeep; Iyer, Venkateswaran K; Khilnani, Gopi C; Guleria, Randeep

    2016-01-01

    Background: Conventional transbronchial needle aspiration (c-TBNA) is an underutilized bronchoscopic modality. Endobronchial ultrasound (EBUS) guided-TBNA though efficacious is an expensive modality, facilities of which are available at only limited centers. c-TBNA is cost-effective and has potential for wide utilization especially in resource-limited settings. Rapid on-site evaluation (ROSE) improves the yield of c-TBNA. Materials and Methods: A retrospective review of the bronchoscopy records (May 2012 to July 2014) was performed. The patients who underwent c-TBNA with ROSE were included in the study and their clinical details were extracted. Convex probe EBUS-TBNA was being regularly performed during the study period by the operators performing c-TBNA. Results: c-TBNA with ROSE was performed in 41 patients with mean age of 42.4 (16.2) years. The most frequently sampled node stations (>90% patients) were the subcarinal and lower right paratracheal. Representative samples could be obtained in 33 out of the 41 patients (80.4%). c-TBNA was diagnostic in 32 [tuberculosis (TB)-8, sarcoidosis-9, and malignancy-15] patients out of the 41 patients. The overall diagnostic yield (sensitivity) of c-TBNA with ROSE was 78%. Mean procedure duration was 18.4 (3.1) min and there were no procedural complications. Conclusion: c-TBNA with ROSE is a safe, efficacious, and cost-effective bronchoscopic modality. When it was performed by operators routinely performing EBUS-TBNA, diagnostic yields similar to that of EBUS-TBNA can be obtained. Even at the centers where EBUS facilities are available, c-TBNA should be routinely performed. PMID:27011437

  5. Benefit of cone-beam computed tomography angiography in acute management of angiographically undetectable ruptured arteriovenous malformations.

    PubMed

    Rahal, Jason P; Malek, Adel M

    2013-10-01

    Ruptured arteriovenous malformations (AVMs) are a frequent cause of intracerebral hemorrhage (ICH). In some cases, compression from the associated hematoma in the acute setting can partially or completely occlude an AVM, making it invisible on conventional angiography techniques. The authors report on the successful use of cone-beam CT angiography (CBCT-A) to precisely identify the underlying angioarchitecture of ruptured AVMs that are not visible on conventional angiography. Three patients presented with ICH for which they underwent examination with CBCT-A in addition to digital subtraction angiography and other imaging modalities, including MR angiography and CT angiography. All patients underwent surgical evacuation due to mass effect from the hematoma. Clinical history, imaging studies, and surgical records were reviewed. Hematoma volumes were calculated. In all 3 cases, CBCT-A demonstrated detailed anatomy of an AVM where no lesion or just a suggestion of a draining vein had been seen with other imaging modalities. Magnetic resonance imaging demonstrated enhancement in 1 patient; CT angiography demonstrated a draining vein in 1 patient; 2D digital subtraction angiography and 3D rotational angiography demonstrated a suggestion of a draining vein in 2 cases and no finding in the third. In the 2 patients in whom CBCT-A was performed prior to surgery, the demonstrated AVM was successfully resected without evidence of a residual lesion. In the third patient, CBCT-A allowed precise targeting of the AVM nidus using Gamma Knife radiosurgery. Cone-beam CT angiography should be considered in the evaluation and subsequent treatment of ICH due to ruptured AVMs. In cases in which the associated hematoma compresses the AVM nidus, CBCT-A can have higher sensitivity and anatomical accuracy than traditional angiographic modalities, including digital subtraction angiography.

  6. [Spatial-temporal analysis and clinical findings of gait: comparison of two modalities of treatment in children with cerebral palsy-spastic hemiplegia. Preliminary report].

    PubMed

    Arellano-Martínez, Irma Tamara; Rodríguez-Reyes, Gerardo; Quiñones-Uriostegui, Ivet; Arellano-Saldaña, María Elena

    2013-01-01

    Cerebral palsy is the most common cause of disability among children. Parent's main concerns are the acquisition and improvement of gait. The aim of this study was to compare long term results of the effect of two modalities of gait training. Quantitative measurement of gait and clinical assessment of the gross motor function classification system and Modified Ashworth Scale were perfomed in 14 patients with Cerebral palsy -spastic hemiplegia and randomizedly assigned into two groups of treatment: the first one using a driven gait orthosis (Lokomat(®)) and the second a gait training a long a rail inside a hydrotherapy tank. Measurements and assessments, above described, were performed immediately and one year after the treatment concluded. Significant change was observed in the gross motor function classification system from II to I among children (p=0.042) and a positive correlation between the shape functional of the march and the gross motor function classification system (r = 0.54, p = 0.042). Patients on the Lokomat(®) training improved on gait symmetry over patients on the conventional therapy (p = 0.05). A year after, this intervention showed tendency to kept the gait patterns only on patients treated with the Lokomat(®) Benefit obtained with either modality was evident for both groups. However, residual effects observed on the Lokomat group, either in clinical assessment or gait parameters, were more promising than in the conventional therapy. Due to the size of the sample used in this study the results are not conclusive and more research must be done on this subject in long term time horizon.

  7. Multipass haemodialysis: a novel dialysis modality

    PubMed Central

    Heaf, James Goya; Axelsen, Mette; Pedersen, Robert Smith

    2013-01-01

    Introduction Most home haemodialysis (HD) modalities are limited to home use since they are based on a single-pass (SP) technique, which requires preparation of large amounts of dialysate. We present a new dialysis method, which requires minimal dialysate volumes, continuously recycled during treatment [multipass HD (MPHD)]. Theoretical calculations suggest that MPHD performed six times weekly for 8 h/night, using a dialysate bath containing 50% of the calculated body water, will achieve urea clearances equivalent to conventional HD 4 h thrice weekly, and a substantial clearance of higher middle molecules. Methods Ten stable HD patients were dialyzed for 4 h using standard SPHD (dialysate flow 500 mL/min). Used dialysate was collected. One week later, an 8-h MPHD was performed. The dialysate volume was 50% of the calculated water volume, the dialysate inflow 500 mL/min−0.5 × ultrafiltration/min and the outflow 500 mL/min + 0.5 × ultrafiltration/min. Elimination rates of urea, creatinine, uric acid, phosphate and β2-microglobulin (B2M) and dialysate saturation were determined hourly. Results Three hours of MPHD removed 49, 54, 50, 51 and 57%, respectively, of the amounts of urea, creatinine, uric acid, phosphate and B2M that were removed by 4 h conventional HD. The corresponding figures after 8 h MPHD were 63, 78, 74, 78 and 111%. Conclusions Clearance of small molecules using MPHD 6 × 8 h/week will exceed traditional HD 3 × 4 h/week. Similarly, clearance of large molecules will significantly exceed traditional HD and HD 5 × 2.5 h/week. This modality will increase patients' freedom of movement compared with traditional home HD. The new method can also be used in the intensive care unit and for automated peritoneal dialysis. PMID:23136214

  8. Multimodal sequence learning.

    PubMed

    Kemény, Ferenc; Meier, Beat

    2016-02-01

    While sequence learning research models complex phenomena, previous studies have mostly focused on unimodal sequences. The goal of the current experiment is to put implicit sequence learning into a multimodal context: to test whether it can operate across different modalities. We used the Task Sequence Learning paradigm to test whether sequence learning varies across modalities, and whether participants are able to learn multimodal sequences. Our results show that implicit sequence learning is very similar regardless of the source modality. However, the presence of correlated task and response sequences was required for learning to take place. The experiment provides new evidence for implicit sequence learning of abstract conceptual representations. In general, the results suggest that correlated sequences are necessary for implicit sequence learning to occur. Moreover, they show that elements from different modalities can be automatically integrated into one unitary multimodal sequence. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Digital multishaker modal testing

    NASA Technical Reports Server (NTRS)

    Blair, M.; Craig, R. R., Jr.

    1983-01-01

    A review of several modal testing techniques is made, along with brief discussions of their advantages and limitations. A new technique is presented which overcomes many of the previous limitations. Several simulated experiments are included to verify the validity and accuracy of the new method. Conclusions are drawn from the simulation studies and recommendations for further work are presented. The complete computer code configured for the simulation study is presented.

  10. Fast Bayesian approach for modal identification using free vibration data, Part I - Most probable value

    NASA Astrophysics Data System (ADS)

    Zhang, Feng-Liang; Ni, Yan-Chun; Au, Siu-Kui; Lam, Heung-Fai

    2016-03-01

    The identification of modal properties from field testing of civil engineering structures is becoming economically viable, thanks to the advent of modern sensor and data acquisition technology. Its demand is driven by innovative structural designs and increased performance requirements of dynamic-prone structures that call for a close cross-checking or monitoring of their dynamic properties and responses. Existing instrumentation capabilities and modal identification techniques allow structures to be tested under free vibration, forced vibration (known input) or ambient vibration (unknown broadband loading). These tests can be considered complementary rather than competing as they are based on different modeling assumptions in the identification model and have different implications on costs and benefits. Uncertainty arises naturally in the dynamic testing of structures due to measurement noise, sensor alignment error, modeling error, etc. This is especially relevant in field vibration tests because the test condition in the field environment can hardly be controlled. In this work, a Bayesian statistical approach is developed for modal identification using the free vibration response of structures. A frequency domain formulation is proposed that makes statistical inference based on the Fast Fourier Transform (FFT) of the data in a selected frequency band. This significantly simplifies the identification model because only the modes dominating the frequency band need to be included. It also legitimately ignores the information in the excluded frequency bands that are either irrelevant or difficult to model, thereby significantly reducing modeling error risk. The posterior probability density function (PDF) of the modal parameters is derived rigorously from modeling assumptions and Bayesian probability logic. Computational difficulties associated with calculating the posterior statistics, including the most probable value (MPV) and the posterior covariance matrix, are addressed. Fast computational algorithms for determining the MPV are proposed so that the method can be practically implemented. In the companion paper (Part II), analytical formulae are derived for the posterior covariance matrix so that it can be evaluated without resorting to finite difference method. The proposed method is verified using synthetic data. It is also applied to modal identification of full-scale field structures.

  11. Basics of cancer immunotherapy.

    PubMed

    Fujioka, Yuki; Nishikawa, Hiroyoshi

    2016-01-01

    The immune system is the body's defense against infectious organisms and other invaders including cancer cells. Cancer immunotherapy, which employs our own immune systems to attack cancer cells, is now emerging as a promising modality of cancer treatment based upon the clinical successes of immune checkpoint blockade and adoptive T cell transfer. In hematologic malignancies, clinical application of anti-PD-1 mAb and CAR (chimeric antigen receptor) T therapy is now being extensively tested in Hodgkin's disease, multiple myeloma, and CD19 + acute lymphocytic leukemia. In sharp contrast to conventional anti-cancer reagents which directly kill cancer cells, cancer immunotherapy activates various types of immune effector cells to attack cancer cells. However, more than half of the treated patients showed no activation of anti-tumor CD8 + killer T cells and CD4 + helper T cells and failed to respond to immune therapies such as immune checkpoint blockade, even when administered in combination regimens. Thus, development of novel immunotherapies to achieve more effective activation of anti-cancer immunity and immuno-monitoring of biomarkers, allowing proper evaluation of immune responses in cancer patients in order to detect responders, are urgent issues. Additionally, we must pay attention to characteristic immunological side effects not observed following treatment with conventional anti-cancer reagents. Herein, we present a summary outline and discuss the future direction of cancer immunotherapy.

  12. Using Dispersed Modes During Model Correlation

    NASA Technical Reports Server (NTRS)

    Stewart, Eric; Hathcock, Megan

    2017-01-01

    Using model dispersions as a starting point allows us to quickly adjust a model to reflect new test data: a) The analyst does a lot of work before the test to save time post-test. b) Creating 1000s of model dispersions to provide "coarse tuning," then use Attune to provide the "fine tuning." ?Successful model tuning on three structures: a) TAURUS. b) Ares I-X C) Cart (in backup charts). ?Mode weighting factors, matrix norm method, and XOR vs. MAC all play key roles in determining the BME. The BME process will be used on future tests: a) ISPE modal test (ongoing work). b) SLS modal test (mid 2018).

  13. Dispersion properties of plasma cladded annular optical fiber

    NASA Astrophysics Data System (ADS)

    KianiMajd, M.; Hasanbeigi, A.; Mehdian, H.; Hajisharifi, K.

    2018-05-01

    One of the considerable problems in a conventional image transferring fiber optic system is the two-fold coupling of propagating hybrid modes. In this paper, using a simple and practical analytical approach based on exact modal vectorial analysis together with Maxwell's equations, we show that applying plasma as a cladding medium of an annular optical fiber can remove this defect of conventional fiber optic automatically without any external instrument as the polarization beam splitter. Moreover, the analysis indicates that the presence of plasma in the proposed optical fiber could extend the possibilities for controlling the propagation property. The proposed structure presents itself as a promising route to advanced optical processing and opens new avenues in applied optics and photonics.

  14. Le Fort I Maxillary Advancement Using Distraction Osteogenesis

    PubMed Central

    Combs, Patrick D.; Harshbarger, Raymond J.

    2014-01-01

    Treatment of maxillary hypoplasia has traditionally involved conventional Le Fort I osteotomies and advancement. Advancements of greater than 10 mm risk significant relapse. This risk is greater in the cleft lip and palate population, whose anatomy and soft tissue scarring from prior procedures contributes to instability of conventional maxillary advancement. Le Fort I advancement with distraction osteogenesis has emerged as viable, stable treatment modality correction of severe maxillary hypoplasia in cleft, syndromic, and noncleft patients. In this article, the authors provide a review of current data and recommendations concerning Le Fort I advancement with distraction osteogenesis. In addition, they outline their technique for treating severe maxillary hypoplasia with distraction osteogenesis using internal devices. PMID:25383054

  15. Optimising the measurement of bruises in children across conventional and cross polarized images using segmentation analysis techniques in Image J, Photoshop and circle diameter measurements.

    PubMed

    Harris, C; Alcock, A; Trefan, L; Nuttall, D; Evans, S T; Maguire, S; Kemp, A M

    2018-02-01

    Bruising is a common abusive injury in children, and it is standard practice to image and measure them, yet there is no current standard for measuring bruise size consistently. We aim to identify the optimal method of measuring photographic images of bruises, including computerised measurement techniques. 24 children aged <11 years (mean age of 6.9, range 2.5-10 years) with a bruise were recruited from the community. Demographics and bruise details were recorded. Each bruise was measured in vivo using a paper measuring tape. Standardised conventional and cross polarized digital images were obtained. The diameter of bruise images were measured by three computer aided measurement techniques: Image J (segmentation with Simple Interactive Object Extraction (maximum Feret diameter), 'Circular Selection Tool' (Circle diameter), & the Photoshop 'ruler' software (Photoshop diameter)). Inter and intra-observer effects were determined by two individuals repeating 11 electronic measurements, and relevant Intraclass Correlation Coefficient's (ICC's) were used to establish reliability. Spearman's rank correlation was used to compare in vivo with computerised measurements; a comparison of measurement techniques across imaging modalities was conducted using Kolmogorov-Smirnov tests. Significance was set at p < 0.05 for all tests. Images were available for 38 bruises in vivo, with 48 bruises visible on cross polarized imaging and 46 on conventional imaging (some bruises interpreted as being single in vivo appeared to be multiple in digital images). Correlation coefficients were >0.5 for all techniques, with maximum Feret diameter and maximum Photoshop diameter on conventional images having the strongest correlation with in vivo measurements. There were significant differences between in vivo and computer-aided measurements, but none between different computer-aided measurement techniques. Overall, computer aided measurements appeared larger than in vivo. Inter- and intra-observer agreement was high for all maximum diameter measurements (ICC's > 0.7). Whilst there are minimal differences between measurements of images obtained, the most consistent results were obtained when conventional images, segmented by Image J Software, were measured with a Feret diameter. This is therefore proposed as a standard for future research, and forensic practice, with the proviso that all computer aided measurements appear larger than in vivo. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  16. A neural basis for category and modality specificity of semantic knowledge.

    PubMed

    Thompson-Schill, S L; Aguirre, G K; D'Esposito, M; Farah, M J

    1999-06-01

    Prevalent theories hold that semantic memory is organized by sensorimotor modality (e.g., visual knowledge, motor knowledge). While some neuroimaging studies support this idea, it cannot account for the category specific (e.g., living things) knowledge impairments seen in some brain damaged patients that cut across modalities. In this article we test an alternative model of how damage to interactive, modality-specific neural regions might give rise to these categorical impairments. Functional MRI was used to examine a cortical area with a known modality-specific function during the retrieval of visual and non-visual knowledge about living and non-living things. The specific predictions of our model regarding the signal observed in this area were confirmed, supporting the notion that semantic memory is functionally segregated into anatomically discrete, but highly interactive, modality-specific regions.

  17. Roles of frequency, attitudes, and multiple intelligence modality surrounding Electricity Content-Based Reader's Theatre

    NASA Astrophysics Data System (ADS)

    Hosier, Julie Winchester

    Integration of subjects is something elementary teachers must do to insure required objectives are covered. Science-based Reader's Theatre is one way to weave reading into science. This study examined the roles of frequency, attitudes, and Multiple Intelligence modalities surrounding Electricity Content-Based Reader's Theatre. This study used quasi-experimental, repeated measures ANOVA with time as a factor design. A convenience sample of two fifth-grade classrooms participated in the study for eighteen weeks. Five Electricity Achievement Tests were given throughout the study to assess students' growth. A Student Reader's Theatre Attitudinal Survey revealed students' attitudes before and after Electricity Content-Based Reader's Theatre treatment. The Multiple Intelligence Inventory for Kids (Faris, 2007) examined whether Multiple Intelligence modality played a role in achievement on Electricity Test 4, the post-treatment test. Analysis using repeated measures ANOVA and an independent t-test found that students in the experimental group, which practiced its student-created Electricity Content-Based Reader's Theatre skits ten times versus two times for the for control group, did significantly better on Electricity Achievement Test 4, t(76) = 3.018, p = 0.003. Dependent t-tests did not find statistically significant differences between students' attitudes about Electricity Content-Based Reader's Theatre before and after treatment. A Kruskal-Wallis test found no statistically significant difference between the various Multiple Intelligence modalities score mean ranks (x2 = 5.57, df = 2, alpha = .062). Qualitative data do, however, indicate students had strong positive feelings about Electricity Content-Based Reader's Theatre after treatment. Students indicated it to be motivating, confidence-building, and a fun way to learn about science; however, they disliked writing their own scripts. Examining the frequency, attitudes, and Multiple Intelligence modalities lead to the conclusion that the role of frequency had the greatest impact on the success of Electricity Content-Based Reader's Theatre. The participating teachers, students, and research found integrating science and reading through Electricity Content-Based Reader's Theatre beneficial.

  18. Seismic damage diagnosis of a masonry building using short-term damping measurements

    NASA Astrophysics Data System (ADS)

    Kouris, Leonidas Alexandros S.; Penna, Andrea; Magenes, Guido

    2017-04-01

    It is of considerable importance to perform dynamic identification and detect damage in existing structures. This paper describes a new and practical method for damage diagnosis of masonry buildings requiring minimum computational effort. The method is based on the relative variation of modal damping and validated against experimental data from a full scale two storey shake table test. The experiment involves a building subjected to uniaxial vibrations of progressively increasing intensity at the facilities of EUCENTRE laboratory (Pavia, Italy) up to a near collapse damage state. Five time-histories are applied scaling the Montenegro (1979) accelerogram. These strong motion tests are preceded by random vibration tests (RVT's) which are used to perform modal analysis. Two deterministic methods are applied: the single degree of freedom (SDOF) assumption together with the peak-picking method in the discrete frequency domain and the Eigen realisation algorithm with data correlations (ERA-DC) in the discrete time domain. Regarding the former procedure, some improvements are incorporated to locate rigorously the natural frequencies and estimate the modal damping. The progressive evolution of the modal damping is used as a key indicator to characterise damage on the building. Modal damping is connected to the structural mass and stiffness. A square integrated but only with two components expression for proportional (classical) damping is proposed to fit better with the experimental measurements of modal damping ratios. Using this Rayleigh order formulation the contribution of each of the damping components is evaluated. The stiffness component coefficient is proposed as an effective index to detect damage and quantify its intensity.

  19. Uncertainty law in ambient modal identification-Part I: Theory

    NASA Astrophysics Data System (ADS)

    Au, Siu-Kui

    2014-10-01

    Ambient vibration test has gained increasing popularity in practice as it provides an economical means for modal identification without artificial loading. Since the signal-to-noise ratio cannot be directly controlled, the uncertainty associated with the identified modal parameters is a primary concern. From a scientific point of view, it is of interest to know on what factors the uncertainty depends and what the relationship is. For planning or specification purposes, it is desirable to have an assessment of the test configuration required to achieve a specified accuracy in the modal parameters. For example, what is the minimum data duration to achieve a 30% coefficient of variation (c.o.v.) in the damping ratio? To address these questions, this work investigates the leading order behavior of the ‘posterior uncertainties’ (i.e., given data) of the modal parameters in a Bayesian identification framework. In the context of well-separated modes, small damping and sufficient data, it is shown rigorously that, among other results, the posterior c.o.v. of the natural frequency and damping ratio are asymptotically equal to ( and 1/(2, respectively; where ζ is the damping ratio; Nc is the data length as a multiple of the natural period; Bf and Bζ are data length factors that depend only on the bandwidth utilized for identification, for which explicit expressions have been derived. As the Bayesian approach allows full use of information contained in the data, the results are fundamental characteristics of the ambient modal identification problem. This paper develops the main theory. The companion paper investigates the implication of the results and verification with field test data.

  20. Comparison of computed radiography and conventional radiography in detection of small volume pneumoperitoneum.

    PubMed

    Marolf, Angela; Blaik, Margaret; Ackerman, Norman; Watson, Elizabeth; Gibson, Nicole; Thompson, Margret

    2008-01-01

    The role of digital imaging is increasing as these systems are becoming more affordable and accessible. Advantages of computed radiography compared with conventional film/screen combinations include improved contrast resolution and postprocessing capabilities. Computed radiography's spatial resolution is inferior to conventional radiography; however, this limitation is considered clinically insignificant. This study prospectively compared digital imaging and conventional radiography in detecting small volume pneumoperitoneum. Twenty cadaver dogs (15-30 kg) were injected with 0.25, 0.25, and 0.5 ml for 1 ml total of air intra-abdominally, and radiographed sequentially using computed and conventional radiographic technologies. Three radiologists independently evaluated the images, and receiver operating curve (ROC) analysis compared the two imaging modalities. There was no statistical difference between computed and conventional radiography in detecting free abdominal air, but overall computed radiography was relatively more sensitive based on ROC analysis. Computed radiographic images consistently and significantly demonstrated a minimal amount of 0.5 ml of free air based on ROC analysis. However, no minimal air amount was consistently or significantly detected with conventional film. Readers were more likely to detect free air on lateral computed images than the other projections, with no significant increased sensitivity between film/screen projections. Further studies are indicated to determine the differences or lack thereof between various digital imaging systems and conventional film/screen systems.

  1. Composite Bending Box Section Modal Vibration Fault Detection

    NASA Technical Reports Server (NTRS)

    Werlink, Rudy

    2002-01-01

    One of the primary concerns with Composite construction in critical structures such as wings and stabilizers is that hidden faults and cracks can develop operationally. In the real world, catastrophic sudden failure can result from these undetected faults in composite structures. Vibration data incorporating a broad frequency modal approach, could detect significant changes prior to failure. The purpose of this report is to investigate the usefulness of frequency mode testing before and after bending and torsion loading on a composite bending Box Test section. This test article is representative of construction techniques being developed for the recent NASA Blended Wing Body Low Speed Vehicle Project. The Box section represents the construction technique on the proposed blended wing aircraft. Modal testing using an impact hammer provides an frequency fingerprint before and after bending and torsional loading. If a significant structural discontinuity develops, the vibration response is expected to change. The limitations of the data will be evaluated for future use as a non-destructive in-situ method of assessing hidden damage in similarly constructed composite wing assemblies. Modal vibration fault detection sensitivity to band-width, location and axis will be investigated. Do the sensor accelerometers need to be near the fault and or in the same axis? The response data used in this report was recorded at 17 locations using tri-axial accelerometers. The modal tests were conducted following 5 independent loading conditions before load to failure and 2 following load to failure over a period of 6 weeks. Redundant data was used to minimize effects from uncontrolled variables which could lead to incorrect interpretations. It will be shown that vibrational modes detected failure at many locations when skin de-bonding failures occurred near the center section. Important considerations are the axis selected and frequency range.

  2. Clinical feasibility study of combined opto-acoustic and ultrasonic imaging modality providing coregistered functional and anatomical maps of breast tumors

    NASA Astrophysics Data System (ADS)

    Zalev, Jason; Clingman, Bryan; Smith, Remie J.; Herzog, Don; Miller, Tom; Stavros, A. Thomas; Ermilov, Sergey; Conjusteau, André; Tsyboulski, Dmitri; Oraevsky, Alexander A.; Kist, Kenneth; Dornbluth, N. C.; Otto, Pamela

    2013-03-01

    We report on findings from the clinical feasibility study of the ImagioTM. Breast Imaging System, which acquires two-dimensional opto-acoustic (OA) images co-registered with conventional ultrasound using a specialized duplex hand-held probe. Dual-wavelength opto-acoustic technology is used to generate parametric maps based upon total hemoglobin and its oxygen saturation in breast tissues. This may provide functional diagnostic information pertaining to tumor metabolism and microvasculature, which is complementary to morphological information obtained with conventional gray-scale ultrasound. We present co-registered opto-acoustic and ultrasonic images of malignant and benign tumors from a recent clinical feasibility study. The clinical results illustrate that the technology may have the capability to improve the efficacy of breast tumor diagnosis. In doing so, it may have the potential to reduce biopsies and to characterize cancers that were not seen well with conventional gray-scale ultrasound alone.

  3. Comparison of CT angiography with conventional arterial angiography in aortoiliac occlusive disease.

    PubMed

    Tins, B; Oxtoby, J; Patel, S

    2001-03-01

    This study compared the results of conventional and CT angiography of the aortoiliac segment in 35 patients with occlusive disease. Disease severity was graded into five categories. Two assessors independently assessed the segment from the distal abdominal aorta to the proximal superficial femoral artery and a consensus was formed. There was interobserver agreement in 87% of segments for conventional angiography and in 78% for CT angiography. Comparison of the two modalities gave identical grading in 84% of segments. Dissimilar grading was found in 16%, with a roughly equal number of undergrading and overgrading. CT angiography has the advantages of being minimally invasive, requiring only an intravenous injection of contrast medium and imaging surrounding soft tissues. Multiplanar reconstruction aids the visualization of asymmetrical stenoses, and collateral blood supply is readily appreciated. However, CT angiography may fail to demonstrate short stenoses owing to limited z-axis resolution.

  4. Simulation tools for analyzer-based x-ray phase contrast imaging system with a conventional x-ray source

    NASA Astrophysics Data System (ADS)

    Caudevilla, Oriol; Zhou, Wei; Stoupin, Stanislav; Verman, Boris; Brankov, J. G.

    2016-09-01

    Analyzer-based X-ray phase contrast imaging (ABI) belongs to a broader family of phase-contrast (PC) X-ray imaging modalities. Unlike the conventional X-ray radiography, which measures only X-ray absorption, in PC imaging one can also measures the X-rays deflection induced by the object refractive properties. It has been shown that refraction imaging provides better contrast when imaging the soft tissue, which is of great interest in medical imaging applications. In this paper, we introduce a simulation tool specifically designed to simulate the analyzer-based X-ray phase contrast imaging system with a conventional polychromatic X-ray source. By utilizing ray tracing and basic physical principles of diffraction theory our simulation tool can predicting the X-ray beam profile shape, the energy content, the total throughput (photon count) at the detector. In addition we can evaluate imaging system point-spread function for various system configurations.

  5. Utility of Functional Hemodynamics and Echocardiography to Aid Diagnosis and Management of Shock.

    PubMed

    McGee, William T; Raghunathan, Karthik; Adler, Adam C

    2015-12-01

    The utility of functional hemodynamics and bedside ultrasonography is increasingly recognized as advantageous for both improved diagnosis and management of shock states. In contrast to conventional "static" measures, "dynamic" hemodynamic measures and bedside imaging modalities enhance pathophysiology-based comprehensive understanding of shock states and the response to therapy. The current editions of major textbooks in the primary specialties--in which clinicians routinely encounter patients in shock--including surgery, anesthesia, emergency medicine, and internal medicine continue to incorporate traditional (conventional) descriptions of shock that use well-described (but potentially misleading) intravascular pressures to classify shock states. Reliance on such intravascular pressure measurements is not as helpful as newer "dynamic" functional measures including ultrasonography to both better assess volume responsiveness and biventricular cardiac function. This review thus emphasizes the application of current functional hemodynamics and ultrasonography to the diagnosis and management of shock as a contrast to conventional "static" pressure-based measures.

  6. Thermoelastic vibration test techniques

    NASA Technical Reports Server (NTRS)

    Kehoe, Michael W.; Snyder, H. Todd

    1991-01-01

    The structural integrity of proposed high speed aircraft can be seriously affected by the extremely high surface temperatures and large temperature gradients throughout the vehicle's structure. Variations in the structure's elastic characteristics as a result of thermal effects can be observed by changes in vibration frequency, damping, and mode shape. Analysis codes that predict these changes must be correlated and verified with experimental data. The experimental modal test techniques and procedures used to conduct uniform, nonuniform, and transient thermoelastic vibration tests are presented. Experimental setup and elevated temperature instrumentation considerations are also discussed. Modal data for a 12 by 50 inch aluminum plate heated to a temperature of 475 F are presented. These data show the effect of heat on the plate's modal characteristics. The results indicated that frequency decreased, damping increased, and mode shape remained unchanged as the temperature of the plate was increased.

  7. Repetition priming with Japanese Kana scripts in word-fragment completion.

    PubMed

    Komatsu, S; Naito, M

    1992-03-01

    Manipulating two types of Japanese Kana script, Katakana and Hiragana, we examined the effects of a script change between study and test on later word-fragment completion. Throughout three experiments, materials were composed of foreign loan nouns normally written in Katakana, but not in Hiragana, according to approved usage in Japanese. Experiment 1 demonstrated the reliable size of cross-script priming between Katakana and Hiragana. In Experiment 2, cross-modal priming was substantial when modality of presentation was changed from auditory to visual. In Experiment 3, generating a target word from its definition induced priming comparable in size to that in the prior reading condition. These results have been confirmed in the Hiragana test, as well as in the Katakana test, thereby suggesting that some conceptual and modality-independent processes may also mediate repetition priming.

  8. Hybrid motion sensing and experimental modal analysis using collocated smartphone camera and accelerometers

    NASA Astrophysics Data System (ADS)

    Ozer, Ekin; Feng, Dongming; Feng, Maria Q.

    2017-10-01

    State-of-the-art multisensory technologies and heterogeneous sensor networks propose a wide range of response measurement opportunities for structural health monitoring (SHM). Measuring and fusing different physical quantities in terms of structural vibrations can provide alternative acquisition methods and improve the quality of the modal testing results. In this study, a recently introduced SHM concept, SHM with smartphones, is focused to utilize multisensory smartphone features for a hybridized structural vibration response measurement framework. Based on vibration testing of a small-scale multistory laboratory model, displacement and acceleration responses are monitored using two different smartphone sensors, an embedded camera and accelerometer, respectively. Double-integration or differentiation among different measurement types is performed to combine multisensory measurements on a comparative basis. In addition, distributed sensor signals from collocated devices are processed for modal identification, and performance of smartphone-based sensing platforms are tested under different configuration scenarios and heterogeneity levels. The results of these tests show a novel and successful implementation of a hybrid motion sensing platform through multiple sensor type and device integration. Despite the heterogeneity of motion data obtained from different smartphone devices and technologies, it is shown that multisensory response measurements can be blended for experimental modal analysis. Getting benefit from the accessibility of smartphone technology, similar smartphone-based dynamic testing methodologies can provide innovative SHM solutions with mobile, programmable, and cost-free interfaces.

  9. Ultrasound guidance to perform intra-articular injection of gadolinium-based contrast material for magnetic resonance arthrography as an alternative to fluoroscopy: the time is now.

    PubMed

    Messina, Carmelo; Banfi, Giuseppe; Aliprandi, Alberto; Mauri, Giovanni; Secchi, Francesco; Sardanelli, Francesco; Sconfienza, Luca Maria

    2016-05-01

    Magnetic resonance (MR) imaging has been definitively established as the reference standard in the evaluation of joints in the body. Similarly, magnetic resonance arthrography has emerged as a technique that has been proven to increase significantly the diagnostic performance if compared with conventional MR imaging, especially when dealing with fibrocartilage and articular cartilage abnormalities. Diluted gadolinium can be injected in the joint space using different approaches: under palpation using anatomic landmarks or using an imaging guidance, such as fluoroscopy, computed tomography, or ultrasound. Fluoroscopy has been traditionally used, but the involvement of ionizing radiation should represent a remarkable limitation of this modality. Conversely, ultrasound has emerged as a feasible, cheap, quick, and radiation-free modality that can be used to inject joints, with comparable accuracy of fluoroscopy. In the present paper, we discuss the advantages and disadvantages of using fluoroscopy or ultrasound in injecting gadolinium-based contrast agents in joints to perform magnetic resonance arthrography, also in view of the new EuroSAFE Imaging initiative promoted by the European Society of Radiology and the recent updates to the European Atomic Energy Community 2013/59 directive on the medical use of ionizing radiation. • Intra-articular contrast agent injection can be performed using different imaging modalities • Fluoroscopy is widely used, but uses ionizing radiation • Ultrasound is an accurate, quick, and radiation-free modality for joint injection • X-rays should be avoided when other radiation-free modalities can be used.

  10. Effect of povidone 2% preservative-free eyedrops on contact lens wearers with computer visual syndrome: pilot study.

    PubMed

    Guillon, Michel; Maissa, Cecile; Pouliquen, Pascale; Delval, Laurent

    2004-01-01

    To show that the use of povidone 2% preservative-free lubricating eyedrops reduces computer visual syndrome in contact lens wearers and to identify the best eyedrop instillation protocols. The test product was FILMABAK a CE-marked nonpreserved lubricant, povidone 2% delivered by the ABAK system. Three dispensing modalities were evaluated during contact lens wear and computer use: hourly instillation, symptom-related instillation, and patient's own instillation. During sustained computer use, a decrease in symptoms associated with the use of povidone 2% was statistically and clinically significant. However, the symptoms were not fully eliminated by the use of the test eyedrop. The three instillation routines achieved similar beneficial effects. No significant changes in ocular tissue response were observed, and the staining recorded after sustained computer use remained low. The use of povidone 2% preservative-free lubricating eyedrops under any of the three instillation modalities tested was also associated with a slight improvement in dynamic visual acuity. The use of povidone 2% preservative-free eyedrops was associated with an improvement in symptoms during sustained computer use. Any of the three instillation modalities decreased symptoms of ocular tiredness, dryness, and difficulty of focus; maintained an unchanged corneal surface; and improved dynamic visual acuity. Therefore, the most patient-friendly modality (patient's own instillation modality from symptom onset) could be recommended to contact lens wearers with computer visual syndrome.

  11. Echocardiography in mitral stenosis

    PubMed Central

    Omran, A.S.; Arifi, Ahmed A.; Mohamed, A.A.

    2010-01-01

    Echocardiography plays a major role in diagnosis, etiology and severity of Mitral Stenosis (MS), analysis of valve anatomy and decision-making for intervention. This technique has also a crucial role to assess consequences of MS and follow up of patients after medical or surgical intervention. In this article we review the role of conventional echocardiography in assessment of mitral stenosis and future direction of this modality using 3D echocardiography. PMID:23960637

  12. Combination of Surgical Drainage and Renal Artery Embolization: An Alternative Treatment for Xanthogranulomatous Pyelonephritis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Upasani, Anand, E-mail: anand.upasani@gosh.nhs.uk; Barnacle, Alex, E-mail: alex.barnacle@gosh.nhs.uk; Roebuck, Derek, E-mail: derek.roebuck@gosh.nhs.uk

    Conventionally, xanthogranulomatous pyelonephritis is treated with antibiotics and drainage of abscess followed by nephrectomy for definitive treatment. Surgical excision of the affected kidney carries risk of significant complications. An alternative treatment modality is described in the form of embolization of the renal artery to devascularise the renal parenchyma and ablate the renal tissue, thus avoiding a major surgical procedure and the significant risks involved.

  13. Citric acid treatment of chronic nonhealing ulcerated tophaceous gout with bursitis.

    PubMed

    Nagoba, Basavaraj S; Punpale, Ajay; Poddar, Ashok; Suryawanshi, Namdev M; Swami, Ganesh A; Selkar, Sohan P

    2013-12-01

    The ulceration associated with gout tophi is very difficult to treat because of impaired and halted local inflammatory response resulting from the gout treatment regimen. We report chronic nonhealing tophaceous gout with bursitis in an 80-year-old male, not responding to conventional treatment modality for months together. This nonhealing ulcer was treated successfully with local application of 3% citric acid ointment for 22 days.

  14. Factors related to the parallel use of complementary and alternative medicine with conventional medicine among patients with chronic conditions in South Korea.

    PubMed

    Choi, Byunghee; Han, Dongwoon; Na, Seonsam; Lim, Byungmook

    2017-06-01

    This study aims to examine the characteristics and behavioral patterns of patients with chronic conditions behind their parallel use of the conventional medicine (CM) and the complementary and alternative medicine (CAM) that includes traditional Korean Medicine (KM). This cross-sectional study used the self-administered anonymous survey method to obtain the results from inpatients who were staying in three hospitals in Gyeongnam province in Korea. Of the 423 participants surveyed, 334 participants (79.0%) used some form of CAM among which KM therapies were the most common modalities. The results of a logistic regression analysis showed that the parallel use pattern was most apparent in the groups aged over 40. Patients with hypertension or joint diseases were seen to have higher propensity to show the parallel use patterns, whereas patients with diabetes were not. In addition, many sociodemographic and health-related characteristics are related to the patterns of the parallel use of CAM and CM. In the rural area of Korea, most inpatients who used CM for the management of chronic conditions used CAM in parallel. KM was the most common in CAM modalities, and the aspect of parallel use varied according to the disease conditions.

  15. Improved In vivo Assessment of Pulmonary Fibrosis in Mice using X-Ray Dark-Field Radiography

    NASA Astrophysics Data System (ADS)

    Yaroshenko, Andre; Hellbach, Katharina; Yildirim, Ali Önder; Conlon, Thomas M.; Fernandez, Isis Enlil; Bech, Martin; Velroyen, Astrid; Meinel, Felix G.; Auweter, Sigrid; Reiser, Maximilian; Eickelberg, Oliver; Pfeiffer, Franz

    2015-12-01

    Idiopathic pulmonary fibrosis (IPF) is a chronic and progressive lung disease with a median life expectancy of 4-5 years after initial diagnosis. Early diagnosis and accurate monitoring of IPF are limited by a lack of sensitive imaging techniques that are able to visualize early fibrotic changes at the epithelial-mesenchymal interface. Here, we report a new x-ray imaging approach that directly visualizes the air-tissue interfaces in mice in vivo. This imaging method is based on the detection of small-angle x-ray scattering that occurs at the air-tissue interfaces in the lung. Small-angle scattering is detected with a Talbot-Lau interferometer, which provides the so-called x-ray dark-field signal. Using this imaging modality, we demonstrate-for the first time-the quantification of early pathogenic changes and their correlation with histological changes, as assessed by stereological morphometry. The presented radiography method is significantly more sensitive in detecting morphological changes compared with conventional x-ray imaging, and exhibits a significantly lower radiation dose than conventional x-ray CT. As a result of the improved imaging sensitivity, this new imaging modality could be used in future to reduce the number of animals required for pulmonary research studies.

  16. The use of various X-ray fluorescence analysis modalities for the investigation of historical paintings: The case study on the Late Gothic panel painting

    NASA Astrophysics Data System (ADS)

    Bártová, H.; Trojek, T.; Čechák, T.; Šefců, R.; Chlumská, Š.

    2017-10-01

    The presence of heavy chemical elements in old pigments is possible to identify in historical paintings using X-ray fluorescence analysis (XRF). This is a non-destructive analytical method frequently used in examination of objects that require in situ analysis, where it is necessary to avoid damaging the object by taking samples. Different modalities are available, such as microanalysis, scanning selected areas, or depth profiling techniques. Surface scanning is particularly profitable since 2D element distribution maps are much more understandable than the results of individual analyses. Information on the layered structure of the painting can be also obtained by handheld portable systems. Results presented in our paper combine 2D element distribution maps obtained by scanning analysis, and depth profiling using conventional XRF. The latter is very suitable for objects of art, as it can be evaluated from data measured with portable XRF device. Depth profiling by conventional XRF is based on the differences in X-ray absorption in paint layers. The XRF technique was applied for analysis of panel paintings of the Master of the St George Altarpiece who was active in Prague in the 1470s and 1480s. The results were evaluated by taking micro-samples and performing a material analysis.

  17. The write way to spell: printing vs. typing effects on orthographic learning

    PubMed Central

    Ouellette, Gene; Tims, Talisa

    2014-01-01

    Prior research has shown superior orthographic learning resulting from spelling practice relative to repeated reading. One mechanism proposed to underlie this advantage of spelling in establishing detailed orthographic representations in memory is the motoric component of the manual movements evoked in printing or writing. This study investigated this contention directly by testing the effects of typing vs. printing on the orthographic learning achieved through spelling practice, and further evaluated whether practice modality interacts with pre-existing individual characteristics. Forty students in grade 2 (mean age 7 years 5 months) were introduced to 10 novel non-words. Some of the students practiced spelling the items by printing, while the others practiced spelling them on a keyboard. Participants were tested for recognition and spelling of these items 1 and 7 days later. Results revealed high rates of orthographic learning with no main effects of practice modality, testing time, or post-test modality. Hierarchical regression analyses revealed an interaction between typing proficiency and practice modality, such that pre-existing keyboarding skills constrained or facilitated learning within the typing-practice group. A similar interaction was not found between printing skills and learning within the printing group. Results are discussed with reference to both prominent reading theory and educational applications. PMID:24592247

  18. Dynamic Testing of a Pre-stretched Flexible Tube for Identifying the Factors Affecting Modal Parameter Estimation

    NASA Astrophysics Data System (ADS)

    Unnikrishnan, Madhusudanan; Rajan, Akash; Basanthvihar Raghunathan, Binulal; Kochupillai, Jayaraj

    2017-08-01

    Experimental modal analysis is the primary tool for obtaining the fundamental dynamic characteristics like natural frequency, mode shape and modal damping ratio that determine the behaviour of any structure under dynamic loading conditions. This paper discusses about a carefully designed experimental method for calculating the dynamic characteristics of a pre-stretched horizontal flexible tube made of polyurethane material. The factors that affect the modal parameter estimation like the application time of shaker excitation, pause time between successive excitation cycles, averaging and windowing of measured signal, as well as the precautions to be taken during the experiment are explained in detail. The modal parameter estimation is done using MEscopeVESTM software. A finite element based pre-stressed modal analysis of the flexible tube is also done using ANSYS ver.14.0 software. The experimental and analytical results agreed well. The proposed experimental methodology may be extended for carrying out the modal analysis of many flexible structures like inflatables, tires and membranes.

  19. Identification of modal parameters including unmeasured forces and transient effects

    NASA Astrophysics Data System (ADS)

    Cauberghe, B.; Guillaume, P.; Verboven, P.; Parloo, E.

    2003-08-01

    In this paper, a frequency-domain method to estimate modal parameters from short data records with known input (measured) forces and unknown input forces is presented. The method can be used for an experimental modal analysis, an operational modal analysis (output-only data) and the combination of both. A traditional experimental and operational modal analysis in the frequency domain starts respectively, from frequency response functions and spectral density functions. To estimate these functions accurately sufficient data have to be available. The technique developed in this paper estimates the modal parameters directly from the Fourier spectra of the outputs and the known input. Instead of using Hanning windows on these short data records the transient effects are estimated simultaneously with the modal parameters. The method is illustrated, tested and validated by Monte Carlo simulations and experiments. The presented method to process short data sequences leads to unbiased estimates with a small variance in comparison to the more traditional approaches.

  20. A Modal Model to Simulate Typical Structural Dynamic Nonlinearity [PowerPoint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mayes, Randall L.; Pacini, Benjamin Robert; Roettgen, Dan

    2016-01-01

    Some initial investigations have been published which simulate nonlinear response with almost traditional modal models: instead of connecting the modal mass to ground through the traditional spring and damper, a nonlinear Iwan element was added. This assumes that the mode shapes do not change with amplitude and there are no interactions between modal degrees of freedom. This work expands on these previous studies. An impact experiment is performed on a structure which exhibits typical structural dynamic nonlinear response, i.e. weak frequency dependence and strong damping dependence on the amplitude of vibration. Use of low level modal test results in combinationmore » with high level impacts are processed using various combinations of modal filtering, the Hilbert Transform and band-pass filtering to develop response data that are then fit with various nonlinear elements to create a nonlinear pseudo-modal model. Simulations of forced response are compared with high level experimental data for various nonlinear element assumptions.« less

  1. A Modal Model to Simulate Typical Structural Dynamic Nonlinearity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pacini, Benjamin Robert; Mayes, Randall L.; Roettgen, Daniel R

    2015-10-01

    Some initial investigations have been published which simulate nonlinear response with almost traditional modal models: instead of connecting the modal mass to ground through the traditional spring and damper, a nonlinear Iwan element was added. This assumes that the mode shapes do not change with amplitude and there are no interactions between modal degrees of freedom. This work expands on these previous studies. An impact experiment is performed on a structure which exhibits typical structural dynamic nonlinear response, i.e. weak frequency dependence and strong damping dependence on the amplitude of vibration. Use of low level modal test results in combinationmore » with high level impacts are processed using various combinations of modal filtering, the Hilbert Transform and band-pass filtering to develop response data that are then fit with various nonlinear elements to create a nonlinear pseudo-modal model. Simulations of forced response are compared with high level experimental data for various nonlinear element assumptions.« less

  2. The Shock and Vibration Digest. Volume 16, Number 4

    DTIC Science & Technology

    1984-04-01

    The 2nd International Modal Analysis Conference, which was held in Orlando, Florida, this past February, was highly successful in all respects. A...announcement of the formation of a new technical society dedicated to advancing the modal analysis technology, the International Society for Modal Testing and... Analysis . This new society is I unique in two respects. First, it is dedicated to a specific branch of a specialized technical field..Second, it is a

  3. The Kansas Squat Test Modality Comparison: Free Weights vs. Smith Machine.

    PubMed

    Luebbers, Paul E; Fry, Andrew C

    2016-08-01

    Luebbers, PE and Fry, AC. The Kansas squat test modality comparison: free weights vs. smith machine. J Strength Cond Res 30(8): 2186-2193, 2016-Standardized methods of testing power are instrumental in planning and implementing training regimens for many athletes, and also in tracking training adaptations. Previous work has demonstrated that the Kansas squat test (KST) is a valid test for measuring indices of mean and peak power when compared with the Wingate anaerobic cycle test. Although the KST was designed for use with a Smith machine (SM), many power athletes use free weights for training. The purpose of this study was to determine the feasibility of using free weights (FW) for the KST by comparing it with the SM modality. Twenty-three track and field athletes participated (mean ± SD; weight, 69.7 ± 10.6 kg; age, 20.1 ± 1.1 years) in this study. Each completed familiarization sessions with the FW and SM modalities before data collection. A 1-repetition maximum squat was also determined for both the FW and SM. Correlation coefficients indicated significant relationships between the FW KST and SM KST on measures of peak test power (r = 0.955; p < 0.01) and mean test power (r = 0.959; p < 0.01) but not for relative fatigue (r = -0.198; p > 0.05) or posttest lactate (r = 0.109; p > 0.05). Paired samples t-tests indicated that the FW KST resulted in significantly higher measures of peak power and mean power (p ≤ 0.01), although no differences were observed for relative fatigue or lactate (p > 0.05). These data indicate that the FW KST is a valid and feasible alternative to the SM KST in measuring peak and mean power.

  4. Multi-modality image fusion based on enhanced fuzzy radial basis function neural networks.

    PubMed

    Chao, Zhen; Kim, Dohyeon; Kim, Hee-Joung

    2018-04-01

    In clinical applications, single modality images do not provide sufficient diagnostic information. Therefore, it is necessary to combine the advantages or complementarities of different modalities of images. Recently, neural network technique was applied to medical image fusion by many researchers, but there are still many deficiencies. In this study, we propose a novel fusion method to combine multi-modality medical images based on the enhanced fuzzy radial basis function neural network (Fuzzy-RBFNN), which includes five layers: input, fuzzy partition, front combination, inference, and output. Moreover, we propose a hybrid of the gravitational search algorithm (GSA) and error back propagation algorithm (EBPA) to train the network to update the parameters of the network. Two different patterns of images are used as inputs of the neural network, and the output is the fused image. A comparison with the conventional fusion methods and another neural network method through subjective observation and objective evaluation indexes reveals that the proposed method effectively synthesized the information of input images and achieved better results. Meanwhile, we also trained the network by using the EBPA and GSA, individually. The results reveal that the EBPGSA not only outperformed both EBPA and GSA, but also trained the neural network more accurately by analyzing the same evaluation indexes. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. Computer-assisted surgery: virtual- and augmented-reality displays for navigation during urological interventions.

    PubMed

    van Oosterom, Matthias N; van der Poel, Henk G; Navab, Nassir; van de Velde, Cornelis J H; van Leeuwen, Fijs W B

    2018-03-01

    To provide an overview of the developments made for virtual- and augmented-reality navigation procedures in urological interventions/surgery. Navigation efforts have demonstrated potential in the field of urology by supporting guidance for various disorders. The navigation approaches differ between the individual indications, but seem interchangeable to a certain extent. An increasing number of pre- and intra-operative imaging modalities has been used to create detailed surgical roadmaps, namely: (cone-beam) computed tomography, MRI, ultrasound, and single-photon emission computed tomography. Registration of these surgical roadmaps with the real-life surgical view has occurred in different forms (e.g. electromagnetic, mechanical, vision, or near-infrared optical-based), whereby the combination of approaches was suggested to provide superior outcome. Soft-tissue deformations demand the use of confirmatory interventional (imaging) modalities. This has resulted in the introduction of new intraoperative modalities such as drop-in US, transurethral US, (drop-in) gamma probes and fluorescence cameras. These noninvasive modalities provide an alternative to invasive technologies that expose the patients to X-ray doses. Whereas some reports have indicated navigation setups provide equal or better results than conventional approaches, most trials have been performed in relatively small patient groups and clear follow-up data are missing. The reported computer-assisted surgery research concepts provide a glimpse in to the future application of navigation technologies in the field of urology.

  6. Shared and distinct factors driving attention and temporal processing across modalities

    PubMed Central

    Berry, Anne S.; Li, Xu; Lin, Ziyong; Lustig, Cindy

    2013-01-01

    In addition to the classic finding that “sounds are judged longer than lights,” the timing of auditory stimuli is often more precise and accurate than is the timing of visual stimuli. In cognitive models of temporal processing, these modality differences are explained by positing that auditory stimuli more automatically capture and hold attention, more efficiently closing an attentional switch that allows the accumulation of pulses marking the passage of time (Block & Zakay, 1997; Meck, 1991; Penney, 2003). However, attention is a multifaceted construct, and there has been little attempt to determine which aspects of attention may be related to modality effects. We used visual and auditory versions of the Continuous Temporal Expectancy Task (CTET; O'Connell et al., 2009) a timing task previously linked to behavioral and electrophysiological measures of mind-wandering and attention lapses, and tested participants with or without the presence of a video distractor. Performance in the auditory condition was generally superior to that in the visual condition, replicating standard results in the timing literature. The auditory modality was also less affected by declines in sustained attention indexed by declines in performance over time. In contrast, distraction had an equivalent impact on performance in the two modalities. Analysis of individual differences in performance revealed further differences between the two modalities: Poor performance in the auditory condition was primarily related to boredom whereas poor performance in the visual condition was primarily related to distractibility. These results suggest that: 1) challenges to different aspects of attention reveal both modality-specific and nonspecific effects on temporal processing, and 2) different factors drive individual differences when testing across modalities. PMID:23978664

  7. Effectiveness of an Ayurveda treatment approach in knee osteoarthritis - a randomized controlled trial.

    PubMed

    Kessler, C S; Dhiman, K S; Kumar, A; Ostermann, T; Gupta, S; Morandi, A; Mittwede, M; Stapelfeldt, E; Spoo, M; Icke, K; Michalsen, A; Witt, C M

    2018-05-01

    Ayurveda is commonly used in South Asia to treat knee osteoarthritis (OA). We aimed to evaluate the effectiveness of Ayurvedic treatment compared to conventional conservative care in patients with knee OA. According to American College of Rheumatology (ACR) criteria knee OA patients were included in a multicenter randomized, controlled, open-label trial and treated in 2 hospital clinics and 2 private outpatient clinics in Germany. Participants received either a multi-modal Ayurvedic treatment or multi-modal conventional care with 15 treatments over 12 weeks respectively. Primary outcome was the change on the Western Ontario and McMaster University Osteoarthritis (WOMAC) Index after 12 weeks. Secondary outcomes included WOMAC subscales; the pain disability index and a pain experience scale, numeric rating scales for pain and sleep quality, quality-of-life and mood, rescue medication use, and safety issues. One hundred fifty-one participants (Ayurveda n = 77, conventional care n = 74) were included. Changes of the WOMAC Index from baseline to 12 weeks were more pronounced in the Ayurveda group (mean difference 61.0 [95%CI: 52.4;69.6]) than in the conventional group (32.0 [95%CI: 21.4;42.6]) resulting in a significant between-group difference (p < 0.001) and a clinically relevant effect size (Cohen's d 0.68 [95% CI:0.35;1.01]). Similar trends were observed for all secondary outcomes at week 12. Effects were sustained at follow-ups after 6 and 12 months. Results suggest that Ayurvedic treatment is beneficial in reducing knee OA symptoms. Further studies should be conducted to confirm the magnitude of the effect and to clarify the role of different treatment components and non-specific effects. REGISTRATION: at clinicaltrials.gov (NCT01225133; initial release 10/06/2010). Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  8. Home, automated office, and conventional office blood pressure as predictors of cardiovascular risk.

    PubMed

    Andreadis, Emmanuel A; Papademetriou, Vasilios; Geladari, Charalampia V; Kolyvas, George N; Angelopoulos, Epameinondas T; Aronis, Konstantinos N

    2017-03-01

    Automated office blood pressure (AOBP) has recently been shown to closely predict cardiovascular (CV) events in the elderly. Home blood pressure (HBP) has also been accepted as a valuable method in the prediction of CV disease. This study aimed to compare conventional office BP (OBP), HBP, and AOBP in order to evaluate their value in predicting CV events and deaths in hypertensives. We assessed 236 initially treatment naïve hypertensives, examined between 2009 and 2013. The end points were any CV and non-CV event including mortality, myocardial infarction, coronary heart disease, hospitalization for heart failure, severe arrhythmia, stroke, and intermittent claudication. We fitted proportional hazards models using the different modalities as predictors and evaluated their predictive performance using three metrics: time-dependent receiver operating characteristics curves, the Akaike's Information Criterion, and Harrell's C-index. After a mean follow-up of 7 years, 23 participants (39% women) had experienced ≥1 CV event. Conventional office systolic (hazard ratio [HR] per 1 mm Hg increase in BP, 1.028; 95% confidence interval [CI], 1.009-1.048), automated office systolic (HR per 1 mm Hg increase in BP, 1.031; 95% CI, 1.008-1.054), and home systolic (HR, 1.025; 95% CI, 1.003-1.047) were predictive of CV events. All systolic BP measurements were predictive after adjustment for other CV risk factors (P < .05). The predictive performance of the different modalities was similar. Conventional OBP was significantly higher than AOBP and average HBP. AOBP predicts equally well to OBP and HBP CV events. It appears to be comparable to HBP in the assessment of CV risk, and therefore, its introduction into guidelines and clinical practice as the reference method for assessing BP in the office seems reasonable after verification of these findings by randomized trials. Copyright © 2017 American Society of Hypertension. All rights reserved.

  9. International Space Station Modal Correction Analysis

    NASA Technical Reports Server (NTRS)

    Fotz[atrocl. Lrostom; Grugoer. < ocjae; Laible, Michael; Sugavanam, Sujatha

    2012-01-01

    This paper summarizes the on-orbit modal test and the related modal analysis, model validation and correlation performed for the ISS Stage ULF4, DTF S4-1A, October 11,2010, GMT 284/06:13:00.00. The objective of this analysis is to validate and correlate analytical models with the intent to verify the ISS critical interface dynamic loads and improve fatigue life prediction. For the ISS configurations under consideration, on-orbit dynamic responses were collected with Russian vehicles attached and without the Orbiter attached to the ISS. ISS instrumentation systems that were used to collect the dynamic responses during the DTF S4-1A included the Internal Wireless Instrumentation System (IWIS), External Wireless Instrumentation System (EWIS), Structural Dynamic Measurement System (SDMS), Space Acceleration Measurement System (SAMS), Inertial Measurement Unit (IMU) and ISS External Cameras. Experimental modal analyses were performed on the measured data to extract modal parameters including frequency, damping and mode shape information. Correlation and comparisons between test and analytical modal parameters were performed to assess the accuracy of models for the ISS configuration under consideration. Based on the frequency comparisons, the accuracy of the mathematical models is assessed and model refinement recommendations are given. Section 2.0 of this report presents the math model used in the analysis. This section also describes the ISS configuration under consideration and summarizes the associated primary modes of interest along with the fundamental appendage modes. Section 3.0 discusses the details of the ISS Stage ULF4 DTF S4-1A test. Section 4.0 discusses the on-orbit instrumentation systems that were used in the collection of the data analyzed in this paper. The modal analysis approach and results used in the analysis of the collected data are summarized in Section 5.0. The model correlation and validation effort is reported in Section 6.0. Conclusions and recommendations drawn from this analysis are included in Section 7.0.

  10. [Spanish normative studies in a young adult population (NEURONORMA young adults Project): norms for the verbal span, visuospatial span, Letter-Number Sequencing, Trail Making Test and Symbol Digit Modalities Test].

    PubMed

    Tamayo, F; Casals-Coll, M; Sánchez-Benavides, G; Quintana, M; Manero, R M; Rognoni, T; Calvo, L; Palomo, R; Aranciva, F; Peña-Casanova, J

    2012-01-01

    Verbal and visuospatial span, Letter-Number Sequencing, Trail Making Test, and Symbol Digit Modalities Test are frequently used in clinical practice to assess attention, executive functions and memory. In the present study, as part of the Spanish normative studies of NEURONORMA young adults Project, normative data adjusted by age and education are provided for digits, Corsi Block-Tapping Task, Letter-Number Sequencing, Trail Making Test, and Symbol Digit Modalities Test. The sample consisted of 179 participants from 18 to 49 years old, who were cognitively normal. Tables to convert raw scores to scaled scores are provided. Age and education adjusted scores are provided by applying linear regressions. Education affected scores in most of the attention tests; age was found to be related to the visuospatial span and to speed of visuomotor tracking, and there was no relationship as regards sex. The data obtained will be useful in the clinical evaluation of young Spanish adults. Copyright © 2011 Sociedad Española de Neurología. Published by Elsevier Espana. All rights reserved.

  11. Medical students perception of test anxiety triggered by different assessment modalities.

    PubMed

    Guraya, Salman Y; Guraya, Shaista S; Habib, Fawzia; AlQuiliti, Khalid W; Khoshhal, Khalid I

    2018-05-06

    Test anxiety is well known among medical students. However, little is known about test anxiety produced by different components of exam individually. This study aimed to stratify varying levels of test anxiety provoked by each exam modality and to explore the students perceptions about confounding factors. A self-administered questionnaire was administered to medical students. The instrument contained four main themes; lifestyle, psychological and specific factors of information needs, learning styles, and perceived difficulty level of each assessment tool. A highest test anxiety score of 5 was ranked for "not scheduling available time" and "insufficient exercise" by 28.8 and 28.3% students, respectively. For "irrational thoughts about exam" and "fear to fail", a highest test anxiety score of 5 was scored by 28.8 and 25.7% students, respectively. The highest total anxiety score of 1255 was recorded for long case exam, followed by 975 for examiner-based objective structured clinical examination. Excessive course load and course not well covered by faculty were thought to be the main confounding factors. The examiner-based assessment modalities induced high test anxiety. Faculty is urged to cover core contents within stipulated time and to rigorously reform and update existing curricula to prepare relevant course material.

  12. Unsteady design-point flow phenomena in transonic compressors

    NASA Technical Reports Server (NTRS)

    Gertz, J. B.; Epstein, A. H.

    1986-01-01

    High-frequency response probes which had previously been used exclusively in the MIT Blowndown Facility were successfully employed in two conventional steady state axial flow compressor facilities to investigate the unsteady flowfields of highly loaded transonic compressors at design point operation. Laser anemometry measurements taken simultaneously with the high response data were also analyzed. The time averaged high response data of static and total pressure agreed quite well with the conventional steady state instrumentation except for flow angle which showed a large spread in values at all radii regardless of the type of instrumentation used. In addition, the time resolved measurements confirmed earlier test results obtained in the MIT Blowdown Facility for the same compressor. The results of these tests have further revealed that the flowfields of highly loaded transonic compressors are heavily influenced by unsteady flow phenomena. The high response measurements exhibited large variations in the blade to blade flow and in the blade passage flow. The observed unsteadiness in the blade wakes is explained in terms of the rotor blades' shed vorticity in periodic vortex streets. The wakes were modeled as two-dimensional vortex streets with finite size cores. The model fit the data quite well as it was able to reproduce the average wake shape and bi-modal probability density distributions seen in the laser anemometry data. The presence of vortex streets in the blade wakes also explains the large blade to blade fluctuations seen by the high response probes which is simply due to the intermittent sampling of the vortex street as it is swept past a stationary probe.

  13. Radiologists' confidence in detecting abnormalities on chest images and their subjective judgments of image quality

    NASA Astrophysics Data System (ADS)

    King, Jill L.; Gur, David; Rockette, Howard E.; Curtin, Hugh D.; Obuchowski, Nancy A.; Thaete, F. Leland; Britton, Cynthia A.; Metz, Charles E.

    1991-07-01

    The relationship between subjective judgments of image quality for the performance of specific detection tasks and radiologists' confidence level in arriving at correct diagnoses was investigated in two studies in which 12 readers, using a total of three different display environments, interpreted a series of 300 PA chest images. The modalities used were conventional films, laser-printed films, and high-resolution CRT display of digitized images. For the detection of interstitial disease, nodules, and pneumothoraces, there was no statistically significant correlation (Spearman rho) between subjective ratings of quality and radiologists' confidence in detecting these abnormalities. However, in each study, for all modalities and all readers but one, a small but statistically significant correlation was found between the radiologists' ability to correctly and confidently rule out interstitial disease and their subjective ratings of image quality.

  14. Enamel renal syndrome with associated amelogenesis imperfecta, nephrolithiasis, and hypocitraturia: A case report.

    PubMed

    Bhesania, Dhvani; Arora, Ankit; Kapoor, Sonali

    2015-09-01

    Numerous cases of enamel renal syndrome have been previously reported. Various terms, such as enamel renal syndrome, amelogenesis imperfecta and gingival fibromatosis syndrome, and enamel-renal-gingival syndrome, have been used for patients presenting with the dental phenotype characteristic of this condition, nephrocalcinosis or nephrolithiasis, and gingival findings. This report describes a case of amelogenesis imperfecta of the enamel agenesis variety with nephrolithiasis in a 21-year-old male patient who complained of small teeth. The imaging modalities employed were conventional radiography, cone-beam computed tomography, and renal sonography. Such cases are first encountered by dentists, as other organ or metabolic diseases are generally hidden. Hence, cases of amelogenesis imperfecta should be subjected to advanced diagnostic modalities, incorporating both dental and medical criteria, in order to facilitate comprehensive long-term management.

  15. Comparing Free-Free and Shaker Table Model Correlation Methods Using Jim Beam

    NASA Technical Reports Server (NTRS)

    Ristow, James; Smith, Kenneth Wayne, Jr.; Johnson, Nathaniel; Kinney, Jackson

    2018-01-01

    Finite element model correlation as part of a spacecraft program has always been a challenge. For any NASA mission, the coupled system response of the spacecraft and launch vehicle can be determined analytically through a Coupled Loads Analysis (CLA), as it is not possible to test the spacecraft and launch vehicle coupled system before launch. The value of the CLA is highly dependent on the accuracy of the frequencies and mode shapes extracted from the spacecraft model. NASA standards require the spacecraft model used in the final Verification Loads Cycle to be correlated by either a modal test or by comparison of the model with Frequency Response Functions (FRFs) obtained during the environmental qualification test. Due to budgetary and time constraints, most programs opt to correlate the spacecraft dynamic model during the environmental qualification test, conducted on a large shaker table. For any model correlation effort, the key has always been finding a proper definition of the boundary conditions. This paper is a correlation case study to investigate the difference in responses of a simple structure using a free-free boundary, a fixed boundary on the shaker table, and a base-drive vibration test, all using identical instrumentation. The NAVCON Jim Beam test structure, featured in the IMAC round robin modal test of 2009, was selected as a simple, well recognized and well characterized structure to conduct this investigation. First, a free-free impact modal test of the Jim Beam was done as an experimental control. Second, the Jim Beam was mounted to a large 20,000 lbf shaker, and an impact modal test in this fixed configuration was conducted. Lastly, a vibration test of the Jim Beam was conducted on the shaker table. The free-free impact test, the fixed impact test, and the base-drive test were used to assess the effect of the shaker modes, evaluate the validity of fixed-base modeling assumptions, and compare final model correlation results between these boundary conditions.

  16. Pharmacological Stress Cardiovascular Magnetic Resonance

    PubMed Central

    Chotenimitkhun, Runyawan; Hundley, W. Gregory

    2013-01-01

    Over the past decade, cardiovascular magnetic resonance (CMR) has evolved into a cardiac stress testing modality that can be used to diagnose myocardial ischemia using intravenous dobutamine or vasodilator perfusion agents such as adenosine or dipyridamole. Because CMR produces high-resolution tomographic images of the human heart in multiple imaging planes, it has become a highly attractive noninvasive testing modality for those suspected of having myocardial ischemia. The purpose of this article is to review the clinical, diagnostic, and prognostic utility of stress CMR testing for patients with (or suspected of having) coronary artery disease. PMID:21566427

  17. Membrane Vibration Tests Using Surface-Bonded Piezoelectric Patch Actuation

    NASA Technical Reports Server (NTRS)

    Gasper, James L.; Pappa, Richard S.

    2003-01-01

    This paper describes the status of on-going work at the NASA Langley Research Center to measure the dynamics of thin membranes. The test article is a one-meter square pre-tensioned Kapton membrane that incorporates small surface-bonded piezoelectric patches strategically positioned to excite many modes. It is shown that PVDF (polyvinylidene fluoride) and MFC (macro fiber composite) piezoelectric patch actuators provide adequate excitation energy to obtain modal frequencies and mode shapes. Results from modal tests performed on the membrane using piezoelectric patches of different sizes and positions are discussed.

  18. Identification of Historical Veziragasi Aqueduct Using the Operational Modal Analysis

    PubMed Central

    Ercan, E.; Nuhoglu, A.

    2014-01-01

    This paper describes the results of a model updating study conducted on a historical aqueduct, called Veziragasi, in Turkey. The output-only modal identification results obtained from ambient vibration measurements of the structure were used to update a finite element model of the structure. For the purposes of developing a solid model of the structure, the dimensions of the structure, defects, and material degradations in the structure were determined in detail by making a measurement survey. For evaluation of the material properties of the structure, nondestructive and destructive testing methods were applied. The modal analysis of the structure was calculated by FEM. Then, a nondestructive dynamic test as well as operational modal analysis was carried out and dynamic properties were extracted. The natural frequencies and corresponding mode shapes were determined from both theoretical and experimental modal analyses and compared with each other. A good harmony was attained between mode shapes, but there were some differences between natural frequencies. The sources of the differences were introduced and the FEM model was updated by changing material parameters and boundary conditions. Finally, the real analytical model of the aqueduct was put forward and the results were discussed. PMID:24511287

  19. Modal Testing of the NPSAT1 Engineering Development Unit

    DTIC Science & Technology

    2012-07-01

    erkläre ich, dass die vorliegende Master Arbeit von mir selbstständig und nur unter Verwendung der angegebenen Quellen und Hilfsmittel angefertigt...logarithmic scale . As 5 Figure 2 shows, natural frequencies are indicated by large values of the first CMIF (peaks), and multiple modes can be detected by...structure’s behavior. Ewins even states, “that no large- scale modal test should be permitted to proceed until some preliminary SDOF analyses have

  20. Age-Differences in Environment Route Learning: The Role of Input and Recall-Test Modalities in Young and Older Adults

    ERIC Educational Resources Information Center

    Meneghetti, Chiara; Borella, Erika; Gyselinck, Valerie; De Beni, Rossana

    2012-01-01

    The aim of this research was to examine age-related differences in young and older adults in route learning, using different types of learning and recall test modalities. A sample of young adults (20-30 years old) and older adults (60-70 years old) learned a city route by using either a map or a description; they then performed a verification…

  1. Use of Modality and Negation in Semantically-Informed Syntactic MT

    DTIC Science & Technology

    2012-06-01

    Longman Dictionary of Contemporary English (LDOCE). 422 Baker et al. Modality and Negation in SIMT We produced the full English MN lexicon semi...English sentence pairs, and a bilingual dictionary with 113,911 entries. For our development and test sets, we split the NIST MT-08 test set into two...for combining MT and semantics (termed distillation) to answer the informa- tion needs of monolingual speakers using multilingual sources. Proper

  2. Bayesian operational modal analysis of Jiangyin Yangtze River Bridge

    NASA Astrophysics Data System (ADS)

    Brownjohn, James Mark William; Au, Siu-Kui; Zhu, Yichen; Sun, Zhen; Li, Binbin; Bassitt, James; Hudson, Emma; Sun, Hongbin

    2018-09-01

    Vibration testing of long span bridges is becoming a commissioning requirement, yet such exercises represent the extreme of experimental capability, with challenges for instrumentation (due to frequency range, resolution and km-order separation of sensor) and system identification (because of the extreme low frequencies). The challenge with instrumentation for modal analysis is managing synchronous data acquisition from sensors distributed widely apart inside and outside the structure. The ideal solution is precisely synchronised autonomous recorders that do not need cables, GPS or wireless communication. The challenge with system identification is to maximise the reliability of modal parameters through experimental design and subsequently to identify the parameters in terms of mean values and standard errors. The challenge is particularly severe for modes with low frequency and damping typical of long span bridges. One solution is to apply 'third generation' operational modal analysis procedures using Bayesian approaches in both the planning and analysis stages. The paper presents an exercise on the Jiangyin Yangtze River Bridge, a suspension bridge with a 1385 m main span. The exercise comprised planning of a test campaign to optimise the reliability of operational modal analysis, the deployment of a set of independent data acquisition units synchronised using precision oven controlled crystal oscillators and the subsequent identification of a set of modal parameters in terms of mean and variance errors. Although the bridge has had structural health monitoring technology installed since it was completed, this was the first full modal survey, aimed at identifying important features of the modal behaviour rather than providing fine resolution of mode shapes through the whole structure. Therefore, measurements were made in only the (south) tower, while torsional behaviour was identified by a single measurement using a pair of recorders across the carriageway. The modal survey revealed a first lateral symmetric mode with natural frequency 0.0536 Hz with standard error ±3.6% and damping ratio 4.4% with standard error ±88%. First vertical mode is antisymmetric with frequency 0.11 Hz ± 1.2% and damping ratio 4.9% ± 41%. A significant and novel element of the exercise was planning of the measurement setups and their necessary duration linked to prior estimation of the precision of the frequency and damping estimates. The second novelty is the use of the multi-sensor precision synchronised acquisition without external time reference on a structure of this scale. The challenges of ambient vibration testing and modal identification in a complex environment are addressed leveraging on advances in practical implementation and scientific understanding of the problem.

  3. A new scenario-based approach to damage detection using operational modal parameter estimates

    NASA Astrophysics Data System (ADS)

    Hansen, J. B.; Brincker, R.; López-Aenlle, M.; Overgaard, C. F.; Kloborg, K.

    2017-09-01

    In this paper a vibration-based damage localization and quantification method, based on natural frequencies and mode shapes, is presented. The proposed technique is inspired by a damage assessment methodology based solely on the sensitivity of mass-normalized experimental determined mode shapes. The present method differs by being based on modal data extracted by means of Operational Modal Analysis (OMA) combined with a reasonable Finite Element (FE) representation of the test structure and implemented in a scenario-based framework. Besides a review of the basic methodology this paper addresses fundamental theoretical as well as practical considerations which are crucial to the applicability of a given vibration-based damage assessment configuration. Lastly, the technique is demonstrated on an experimental test case using automated OMA. Both the numerical study as well as the experimental test case presented in this paper are restricted to perturbations concerning mass change.

  4. Multilevel predictors of colorectal cancer testing modality among publicly and privately insured people turning 50.

    PubMed

    Wheeler, Stephanie B; Kuo, Tzy-Mey; Meyer, Anne Marie; Martens, Christa E; Hassmiller Lich, Kristen M; Tangka, Florence K L; Richardson, Lisa C; Hall, Ingrid J; Smith, Judith Lee; Mayorga, Maria E; Brown, Paul; Crutchfield, Trisha M; Pignone, Michael P

    2017-06-01

    Understanding multilevel predictors of colorectal cancer (CRC) screening test modality can help inform screening program design and implementation. We used North Carolina Medicare, Medicaid, and private, commercially available, health plan insurance claims data from 2003 to 2008 to ascertain CRC test modality among people who received CRC screening around their 50th birthday, when guidelines recommend that screening should commence for normal risk individuals. We ascertained receipt of colonoscopy, fecal occult blood test (FOBT) and fecal immunochemical test (FIT) from billing codes. Person-level and county-level contextual variables were included in multilevel random intercepts models to understand predictors of CRC test modality, stratified by insurance type. Of 12,570 publicly-insured persons turning 50 during the study period who received CRC testing, 57% received colonoscopy, whereas 43% received FOBT/FIT, with significant regional variation. In multivariable models, females with public insurance had lower odds of colonoscopy than males (odds ratio [OR] = 0.68; p < 0.05). Of 56,151 privately-insured persons turning 50 years old who received CRC testing, 42% received colonoscopy, whereas 58% received FOBT/FIT, with significant regional variation. In multivariable models, females with private insurance had lower odds of colonoscopy than males (OR = 0.43; p < 0.05). People living 10-15 miles away from endoscopy facilities also had lower odds of colonoscopy than those living within 5 miles (OR = 0.91; p < 0.05). Both colonoscopy and FOBT/FIT are widely used in North Carolina among insured persons newly age-eligible for screening. The high level of FOBT/FIT use among privately insured persons and women suggests that renewed emphasis on FOBT/FIT as a viable screening alternative to colonoscopy may be important.

  5. Quantitative multi-modal NDT data analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heideklang, René; Shokouhi, Parisa

    2014-02-18

    A single NDT technique is often not adequate to provide assessments about the integrity of test objects with the required coverage or accuracy. In such situations, it is often resorted to multi-modal testing, where complementary and overlapping information from different NDT techniques are combined for a more comprehensive evaluation. Multi-modal material and defect characterization is an interesting task which involves several diverse fields of research, including signal and image processing, statistics and data mining. The fusion of different modalities may improve quantitative nondestructive evaluation by effectively exploiting the augmented set of multi-sensor information about the material. It is the redundantmore » information in particular, whose quantification is expected to lead to increased reliability and robustness of the inspection results. There are different systematic approaches to data fusion, each with its specific advantages and drawbacks. In our contribution, these will be discussed in the context of nondestructive materials testing. A practical study adopting a high-level scheme for the fusion of Eddy Current, GMR and Thermography measurements on a reference metallic specimen with built-in grooves will be presented. Results show that fusion is able to outperform the best single sensor regarding detection specificity, while retaining the same level of sensitivity.« less

  6. An Eigensystem Realization Algorithm (ERA) for modal parameter identification and model reduction

    NASA Technical Reports Server (NTRS)

    Juang, J. N.; Pappa, R. S.

    1985-01-01

    A method, called the Eigensystem Realization Algorithm (ERA), is developed for modal parameter identification and model reduction of dynamic systems from test data. A new approach is introduced in conjunction with the singular value decomposition technique to derive the basic formulation of minimum order realization which is an extended version of the Ho-Kalman algorithm. The basic formulation is then transformed into modal space for modal parameter identification. Two accuracy indicators are developed to quantitatively identify the system modes and noise modes. For illustration of the algorithm, examples are shown using simulation data and experimental data for a rectangular grid structure.

  7. SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morris, R; Lakshmanan, M; Fong, G

    Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scanmore » protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to a minimum while still maintaining clinically viable image quality.« less

  8. Somatosensory disturbance by methylmercury exposure.

    PubMed

    Takaoka, Shigeru; Kawakami, Yoshinobu; Fujino, Tadashi; Oh-ishi, Fumihiro; Motokura, Fukuo; Kumagai, Yoshio; Miyaoka, Tetsu

    2008-05-01

    Minamata disease is methylmercury poisoning from consuming fish and shellfish contaminated by industrial waste. The polluted seafood was widely consumed in the area around Minamata, but many individuals were never examined for or classified as having Minamata disease. Following the determination of the Supreme Court of Japan in October 2004 that the Japanese Government was responsible for spreading Minamata disease, over 13,000 residents came forward to be examined for Minamata disease. We studied 197 residents from the Minamata area who had a history of fish consumption during the polluted period to determine the importance of sensory symptoms and findings in making a diagnosis of Minamata disease. We divided the exposed subjects into non-complicated (E) and complicated (E+N) groups based on the absence or presence of other neurological or neurologically related disorders and compared them to residents in control area (C) after matching for age and sex. We quantitatively measured four somatosensory modalities (minimal tactile sense by Semmes-Weinstein monofilaments, vibration sense, position sense, and two-point discrimination) and did psychophysical tests of fine-surface-texture discrimination. Subjective complaints were higher in groups E and E+N than C. Over 90% of E+N and E subjects displayed a sensory disturbance on conventional neurological examination and 28% had visual constriction. About 50% of the E and E +N groups had upper and lower extremity ataxia and about 70% had truncal ataxia. The prevalence of these neurological findings was significantly higher in exposed subjects than controls. All sensory modalities were impaired in the E and E+N groups. All four quantitatively measured sensory modalities were correlated. The prevalence of complaints, neurological findings, and sensory impairment was similar or a little worse in group E+N than in group E. We conclude that sensory symptoms and findings are important in making the diagnosis of Minamata disease and that they can be determined even in the presence of neurological or neurologically related diseases.

  9. Mechanically assisted 3D ultrasound for pre-operative assessment and guiding percutaneous treatment of focal liver tumors

    NASA Astrophysics Data System (ADS)

    Sadeghi Neshat, Hamid; Bax, Jeffery; Barker, Kevin; Gardi, Lori; Chedalavada, Jason; Kakani, Nirmal; Fenster, Aaron

    2014-03-01

    Image-guided percutaneous ablation is the standard treatment for focal liver tumors deemed inoperable and is commonly used to maintain eligibility for patients on transplant waitlists. Radiofrequency (RFA), microwave (MWA) and cryoablation technologies are all delivered via one or a number of needle-shaped probes inserted directly into the tumor. Planning is mostly based on contrast CT/MRI. While intra-procedural CT is commonly used to confirm the intended probe placement, 2D ultrasound (US) remains the main, and in some centers the only imaging modality used for needle guidance. Corresponding intraoperative 2D US with planning and other intra-procedural imaging modalities is essential for accurate needle placement. However, identification of matching features of interest among these images is often challenging given the limited field-of-view (FOV) and low quality of 2D US images. We have developed a passive tracking arm with a motorized scan-head and software tools to improve guiding capabilities of conventional US by large FOV 3D US scans that provides more anatomical landmarks that can facilitate registration of US with both planning and intra-procedural images. The tracker arm is used to scan the whole liver with a high geometrical accuracy that facilitates multi-modality landmark based image registration. Software tools are provided to assist with the segmentation of the ablation probes and tumors, find the 2D view that best shows the probe(s) from a 3D US image, and to identify the corresponding image from planning CT scans. In this paper, evaluation results from laboratory testing and a phase 1 clinical trial for planning and guiding RFA and MWA procedures using the developed system will be presented. Early clinical results show a comparable performance to intra-procedural CT that suggests 3D US as a cost-effective alternative with no side-effects in centers where CT is not available.

  10. Noninvasive imaging of oral premalignancy and malignancy

    NASA Astrophysics Data System (ADS)

    Wilder-Smith, Petra; Krasieva, T.; Jung, W.; You, J. S.; Chen, Z.; Osann, K.; Tromberg, B.

    2005-04-01

    Objectives: Early detection of cancer and its curable precursors remains the best way to ensure patient survival and quality of life. Despite significant advances in treatment, oral cancer still results in 10,000 U.S. deaths annually, mainly due to the late detection of most oral lesions. Specific aim was to use a combination of non-invasive optical in vivo technologies to test a multi-modality approach to non-invasive diagnostics of oral premalignancy and malignancy. Methods: In the hamster cheek pouch model (120 hamsters), in vivo optical coherence tomography (OCT) and optical Doppler tomography (ODT) mapped epithelial, subepithelial and vascular change throughout carcinogenesis in specific, marked sites. In vivo multi-wavelength multi-photon (MPM) and second harmonic generated (SHG) fluorescence techniques provided parallel data on surface and subsurface tissue structure, specifically collagen presence and structure, cellular presence, and vasculature. Images were diagnosed by 2 blinded, pre-standardized investigators using a standardized scale from 0-6 for all modalities. After sacrifice, histopathological sections were prepared and pathology evaluated on a scale of 0-6. ANOVA techniques compared imaging diagnostics with histopathology. 95% confidence limits of the sensitivity and specificity were established for the diagnostic capability of OCT/ODT+ MPM/SHG using ROC curves and kappa statistics. Results: Imaging data were reproducibly obtained with good accuracy. Carcinogenesis-related structural and vascular changes were clearly visible to tissue depths of 2mm. Sensitivity (OCT/ODT alone: 71-88%; OCT+MPM/SHG: 79-91%) and specificity (OCT alone: 62-83%;OCT+MPM/SHG: 67-90%) compared well with conventional techniques. Conclusions: OCT/ODT and MPM/SHG are promising non-invasive in vivo diagnostic modalities for oral dysplasia and malignancy. Supported by CRFA 30003, CCRP 00-01391V-20235, NIH (LAMMP) RR01192, DOE DE903-91ER 61227, NIH EB-00293 CA91717, NSF BES-86924, AFOSR FA 9550-04-1-0101.

  11. Multi-modality analysis of glucose aqueous solution using photoacoustic and dielectric spectroscopy for non-invasive glucose monitoring

    NASA Astrophysics Data System (ADS)

    Tajima, Takuro; Tanaka, Yujiro; Nakamura, Masahito; Seyama, Michiko

    2017-03-01

    Quantitative analysis of glucose using conventional optical spectroscopy suffers from a lack of repeatability due to high optical scattering in skin tissue. Here we present a multi-modality analysis of glucose aqueous solution using photoacoustic spectroscopy (PAS) and broadband dielectric spectroscopy (BDS). These techniques involve the direct detection of the acoustic and electromagnetic waves propagating through or reflecting from tissue without their being scattered. They therefore have potential for better tolerance to the variation of scattering. For PAS, to differentiate signals induced by water absorption, we select another laser wavelength (1.38 μm) that exhibits the same absorbance for water at 1.61 μm. Furthermore, one of the two photoacoustic signals is used to normalize the variations of acoustic properties in differential signal. Measured results for glucose solutions (0-2 g/dL) showed that the differential signal has a sensitivity of 1.61%/g·dL-1 and a detection limit of 120 mg/dL. We also tested glucose detection with BDS (500 MHz to 50 GHz) by detecting glucose hydration bonding at around 10-20 GHz. Using a partial least square analysis and first derivation on broadband spectra, we obtained an RMS error 19 mg/dL and a detection limit of 59 mg/dL. Using both the low-scattering ultrasonic and microwave detection techniques, we successfully captured the glucose footprint in the physiological range.

  12. Use Of Clinical Decision Analysis In Predicting The Efficacy Of Newer Radiological Imaging Modalities: Radioscintigraphy Versus Single Photon Transverse Section Emission Computed Tomography

    NASA Astrophysics Data System (ADS)

    Prince, John R.

    1982-12-01

    Sensitivity, specificity, and predictive accuracy have been shown to be useful measures of the clinical efficacy of diagnostic tests and can be used to predict the potential improvement in diagnostic certitude resulting from the introduction of a competing technology. This communication demonstrates how the informal use of clinical decision analysis may guide health planners in the allocation of resources, purchasing decisions, and implementation of high technology. For didactic purposes the focus is on a comparison between conventional planar radioscintigraphy (RS) and single photon transverse section emission conputed tomography (SPECT). For example, positive predictive accuracy (PPA) for brain RS in a specialist hospital with a 50% disease prevalance is about 95%. SPECT should increase this predicted accuracy to 96%. In a primary care hospital with only a 15% disease prevalance the PPA is only 77% and SPECT may increase this accuracy to about 79%. Similar calculations based on published data show that marginal improvements are expected with SPECT in the liver. It is concluded that: a) The decision to purchase a high technology imaging modality such as SPECT for clinical purposes should be analyzed on an individual organ system and institutional basis. High technology may be justified in specialist hospitals but not necessarily in primary care hospitals. This is more dependent on disease prevalance than procedure volume; b) It is questionable whether SPECT imaging will be competitive with standard RS procedures. Research should concentrate on the development of different medical applications.

  13. Imaging technologies for preclinical models of bone and joint disorders

    PubMed Central

    2011-01-01

    Preclinical models for musculoskeletal disorders are critical for understanding the pathogenesis of bone and joint disorders in humans and the development of effective therapies. The assessment of these models primarily relies on morphological analysis which remains time consuming and costly, requiring large numbers of animals to be tested through different stages of the disease. The implementation of preclinical imaging represents a keystone in the refinement of animal models allowing longitudinal studies and enabling a powerful, non-invasive and clinically translatable way for monitoring disease progression in real time. Our aim is to highlight examples that demonstrate the advantages and limitations of different imaging modalities including magnetic resonance imaging (MRI), computed tomography (CT), positron emission tomography (PET), single-photon emission computed tomography (SPECT) and optical imaging. All of which are in current use in preclinical skeletal research. MRI can provide high resolution of soft tissue structures, but imaging requires comparatively long acquisition times; hence, animals require long-term anaesthesia. CT is extensively used in bone and joint disorders providing excellent spatial resolution and good contrast for bone imaging. Despite its excellent structural assessment of mineralized structures, CT does not provide in vivo functional information of ongoing biological processes. Nuclear medicine is a very promising tool for investigating functional and molecular processes in vivo with new tracers becoming available as biomarkers. The combined use of imaging modalities also holds significant potential for the assessment of disease pathogenesis in animal models of musculoskeletal disorders, minimising the use of conventional invasive methods and animal redundancy. PMID:22214535

  14. Learning to learn: From within-modality to cross-modality transfer during infancy.

    PubMed

    Hupp, Julie M; Sloutsky, Vladimir M

    2011-11-01

    One critical aspect of learning is the ability to apply learned knowledge to new situations. This ability to transfer is often limited, and its development is not well understood. The current research investigated the development of transfer between 8 and 16 months of age. In Experiment 1, 8- and 16-month-olds (who were established to have a preference to the beginning of a visual sequence) were trained to attend to the end of a sequence. They were then tested on novel visual sequences. Results indicated transfer of learning, with both groups changing baseline preferences as a result of training. In Experiment 2, participants were trained to attend to the end of a visual sequence and were then tested on an auditory sequence. Unlike Experiment 1, only older participants exhibited transfer of learning by changing baseline preferences. These findings suggest that the generalization of learning becomes broader with development, with transfer across modalities developing later than transfer within a modality. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Learning to Learn: From Within-Modality to Cross-Modality Transfer in Infancy

    PubMed Central

    Hupp, Julie M.; Sloutsky, Vladimir M.

    2011-01-01

    One critical aspect of learning is the ability to apply learned knowledge to new situations. This ability to transfer is often limited, and its development is not well understood. The current research investigated the development of transfer between 8- and 16-months of age. In Experiment 1, 8- and 16-month-olds (who were established to have a preference to the beginning of a visual sequence) were trained to attend to the end of a sequence. They were then tested on novel visual sequences. Results indicated transfer of learning, as both groups changed baseline preferences as a result of training. In Experiment 2, participants were trained to attend to the end of a visual sequence and then tested on an auditory sequence. Unlike Experiment 1, only older participants exhibited transfer of learning by changing baseline preferences. These findings suggest that the generalization of learning becomes broader with development, with transfer across modalities developing later than transfer within a modality. PMID:21663920

  16. New bone post-processing tools in forensic imaging: a multi-reader feasibility study to evaluate detection time and diagnostic accuracy in rib fracture assessment.

    PubMed

    Glemser, Philip A; Pfleiderer, Michael; Heger, Anna; Tremper, Jan; Krauskopf, Astrid; Schlemmer, Heinz-Peter; Yen, Kathrin; Simons, David

    2017-03-01

    The aim of this multi-reader feasibility study was to evaluate new post-processing CT imaging tools in rib fracture assessment of forensic cases by analyzing detection time and diagnostic accuracy. Thirty autopsy cases (20 with and 10 without rib fractures in autopsy) were randomly selected and included in this study. All cases received a native whole body CT scan prior to the autopsy procedure, which included dissection and careful evaluation of each rib. In addition to standard transverse sections (modality A), CT images were subjected to a reconstruction algorithm to compute axial labelling of the ribs (modality B) as well as "unfolding" visualizations of the rib cage (modality C, "eagle tool"). Three radiologists with different clinical and forensic experience who were blinded to autopsy results evaluated all cases in a random manner of modality and case. Rib fracture assessment of each reader was evaluated compared to autopsy and a CT consensus read as radiologic reference. A detailed evaluation of relevant test parameters revealed a better accordance to the CT consensus read as to the autopsy. Modality C was the significantly quickest rib fracture detection modality despite slightly reduced statistic test parameters compared to modalities A and B. Modern CT post-processing software is able to shorten reading time and to increase sensitivity and specificity compared to standard autopsy alone. The eagle tool as an easy to use tool is suited for an initial rib fracture screening prior to autopsy and can therefore be beneficial for forensic pathologists.

  17. Extended hours hemodialysis and survival: extended hours, extended evidence?

    PubMed

    Wald, Ron; Perl, Jeffrey

    2016-12-01

    Extended-hours hemodialysis presents another approach to the intensification of therapy for maintenance hemodialysis recipients. Smaller studies have demonstrated several potential benefits with this modality, but the impact on patient-centered outcomes has been unclear. We review the largest published study to compare survival among patients who received extended-hours hemodialysis with those who received conventional hemodialysis. Copyright © 2016 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  18. Update on new technologies in digital mammography

    PubMed Central

    Patterson, Stephanie K; Roubidoux, Marilyn A

    2014-01-01

    Despite controversy regarding mammography’s efficacy, it continues to be the most commonly used breast cancer-screening modality. With the development of digital mammography, some improved benefit has been shown in women with dense breast tissue. However, the density of breast tissue continues to limit the sensitivity of conventional mammography. We discuss the development of some derivative digital technologies, primarily digital breast tomosynthesis, and their strengths, weaknesses, and potential patient impact. PMID:25152634

  19. PSMA-Targeted Nano-Conjugates as Dual-Modality (MRI/PET) Imaging Probes for the Non-Invasive Detection of Prostate Cancer

    DTIC Science & Technology

    2009-10-01

    be made. Currently, iodine based compounds are used to enhance contrast of CT which have the limitations of short imaging window due to rapid...number compared to conventionally used iodine compounds . Nanoparticle based CT contrast agents have been demonstrated for vascular imaging, which...constructs with gamma or positron emitting isotopes through a covalent attachment of a bifunctional chelator to the nanoparticles surface. However, in

  20. On-Chip Biomedical Imaging

    PubMed Central

    Göröcs, Zoltán; Ozcan, Aydogan

    2012-01-01

    Lab-on-a-chip systems have been rapidly emerging to pave the way toward ultra-compact, efficient, mass producible and cost-effective biomedical research and diagnostic tools. Although such microfluidic and micro electromechanical systems achieved high levels of integration, and are capable of performing various important tasks on the same chip, such as cell culturing, sorting and staining, they still rely on conventional microscopes for their imaging needs. Recently several alternative on-chip optical imaging techniques have been introduced, which have the potential to substitute conventional microscopes for various lab-on-a-chip applications. Here we present a critical review of these recently emerging on-chip biomedical imaging modalities, including contact shadow imaging, lensfree holographic microscopy, fluorescent on-chip microscopy and lensfree optical tomography. PMID:23558399

  1. Computed-tomographic and conventional linear-tomographic evaluation of tracheobronchial lesions for laser photoresection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pearlberg, J.L.; Sandler, M.A.; Kvale, P.

    1985-03-01

    Laser therapy is a new modality for treatment of airway lesions. The authors examined 18 patients prior to laser photoresection of tracheobronchial lesions. Thirteen had cancers involving the distal trachea, carina, and/or proximal bronchi; five had benign lesions of the middle or proximal trachea. Each patient was examined by conventional linear tomography (CLT) and computed tomography (CT). CT was valuable in patients who had lesions of the distal trachea, carina, and/or proximal bronchi. Its particular usefulness, and its advantage relative to CLT, consisted in its ability to delineate vascular structures adjacent to the planned area of photoresection. Neither CLT normore » CT was helpful in evaluation of benign lesions of the proximal trachea.« less

  2. The picture superiority effect in a cross-modality recognition task.

    PubMed

    Stenbert, G; Radeborg, K; Hedman, L R

    1995-07-01

    Words and pictures were studied and recognition tests given in which each studied object was to be recognized in both word and picture format. The main dependent variable was the latency of the recognition decision. The purpose was to investigate the effects of study modality (word or picture), of congruence between study and test modalities, and of priming resulting from repeated testing. Experiments 1 and 2 used the same basic design, but the latter also varied retention interval. Experiment 3 added a manipulation of instructions to name studied objects, and Experiment 4 deviated from the others by presenting both picture and word referring to the same object together for study. The results showed that congruence between study and test modalities consistently facilitated recognition. Furthermore, items studied as pictures were more rapidly recognized than were items studied as words. With repeated testing, the second instance was affected by its predecessor, but the facilitating effect of picture-to-word priming exceeded that of word-to-picture priming. The finds suggest a two- stage recognition process, in which the first is based on perceptual familiarity and the second uses semantic links for a retrieval search. Common-code theories that grant privileged access to the semantic code for pictures or, alternatively, dual-code theories that assume mnemonic superiority for the image code are supported by the findings. Explanations of the picture superiority effect as resulting from dual encoding of pictures are not supported by the data.

  3. A prototype hand-held tri-modal instrument for in vivo ultrasound, photoacoustic, and fluorescence imaging

    NASA Astrophysics Data System (ADS)

    Kang, Jeeun; Chang, Jin Ho; Wilson, Brian C.; Veilleux, Israel; Bai, Yanhui; DaCosta, Ralph; Kim, Kang; Ha, Seunghan; Lee, Jong Gun; Kim, Jeong Seok; Lee, Sang-Goo; Kim, Sun Mi; Lee, Hak Jong; Ahn, Young Bok; Han, Seunghee; Yoo, Yangmo; Song, Tai-Kyong

    2015-03-01

    Multi-modality imaging is beneficial for both preclinical and clinical applications as it enables complementary information from each modality to be obtained in a single procedure. In this paper, we report the design, fabrication, and testing of a novel tri-modal in vivo imaging system to exploit molecular/functional information from fluorescence (FL) and photoacoustic (PA) imaging as well as anatomical information from ultrasound (US) imaging. The same ultrasound transducer was used for both US and PA imaging, bringing the pulsed laser light into a compact probe by fiberoptic bundles. The FL subsystem is independent of the acoustic components but the front end that delivers and collects the light is physically integrated into the same probe. The tri-modal imaging system was implemented to provide each modality image in real time as well as co-registration of the images. The performance of the system was evaluated through phantom and in vivo animal experiments. The results demonstrate that combining the modalities does not significantly compromise the performance of each of the separate US, PA, and FL imaging techniques, while enabling multi-modality registration. The potential applications of this novel approach to multi-modality imaging range from preclinical research to clinical diagnosis, especially in detection/localization and surgical guidance of accessible solid tumors.

  4. Environmental enrichment of young adult rats (Rattus norvegicus) in different sensory modalities has long-lasting effects on their ability to learn via specific sensory channels.

    PubMed

    Dolivo, Vassilissa; Taborsky, Michael

    2017-05-01

    Sensory modalities individuals use to obtain information from the environment differ among conspecifics. The relative contributions of genetic divergence and environmental plasticity to this variance remain yet unclear. Numerous studies have shown that specific sensory enrichments or impoverishments at the postnatal stage can shape neural development, with potential lifelong effects. For species capable of adjusting to novel environments, specific sensory stimulation at a later life stage could also induce specific long-lasting behavioral effects. To test this possibility, we enriched young adult Norway rats with either visual, auditory, or olfactory cues. Four to 8 months after the enrichment period we tested each rat for their learning ability in 3 two-choice discrimination tasks, involving either visual, auditory, or olfactory stimulus discrimination, in a full factorial design. No sensory modality was more relevant than others for the proposed task per se, but rats performed better when tested in the modality for which they had been enriched. This shows that specific environmental conditions encountered during early adulthood have specific long-lasting effects on the learning abilities of rats. Furthermore, we disentangled the relative contributions of genetic and environmental causes of the response. The reaction norms of learning abilities in relation to the stimulus modality did not differ between families, so interindividual divergence was mainly driven by environmental rather than genetic factors. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  5. Multimedia instructions and cognitive load theory: effects of modality and cueing.

    PubMed

    Tabbers, Huib K; Martens, Rob L; van Merriënboer, Jeroen J G

    2004-03-01

    Recent research on the influence of presentation format on the effectiveness of multimedia instructions has yielded some interesting results. According to cognitive load theory (Sweller, Van Merriënboer, & Paas, 1998) and Mayer's theory of multimedia learning (Mayer, 2001), replacing visual text with spoken text (the modality effect) and adding visual cues relating elements of a picture to the text (the cueing effect) both increase the effectiveness of multimedia instructions in terms of better learning results or less mental effort spent. The aim of this study was to test the generalisability of the modality and cueing effect in a classroom setting. The participants were 111 second-year students from the Department of Education at the University of Gent in Belgium (age between 19 and 25 years). The participants studied a web-based multimedia lesson on instructional design for about one hour. Afterwards they completed a retention and a transfer test. During both the instruction and the tests, self-report measures of mental effort were administered. Adding visual cues to the pictures resulted in higher retention scores, while replacing visual text with spoken text resulted in lower retention and transfer scores. Only a weak cueing effect and even a reverse modality effect have been found, indicating that both effects do not easily generalise to non-laboratory settings. A possible explanation for the reversed modality effect is that the multimedia instructions in this study were learner-paced, as opposed to the system-paced instructions used in earlier research.

  6. Modal test of Shuttle engine nozzle

    NASA Technical Reports Server (NTRS)

    Johnston, G. D.; Coleman, A. D.

    1983-01-01

    A structural failure occurred on the main propulsion test stand at NSTL causing a hydrogen fire and damage to the engines to be used on the Orbiter Columbia. Scattered accelerometer measurements indicated very high response levels at 254 hertz and 311 hertz. The Engine Office at MSFC asked the Dynamics Test Branch to try and find out what caused the failure. All three nozzles were sent to Huntsville for testing. Modal test data revealed very quickly how the failure occurred in the steerhorn and also pointed out two other structural problems. A complete set of data is presented along with a narrative explanation of the steps taken to identify and verify the structural problem.

  7. Vibro-Acoustics Modal Testing at NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Pappa, Richard S.; Pritchard, Jocelyn I.; Buehrle, Ralph D.

    1999-01-01

    This paper summarizes on-going modal testing activities at the NASA Langley Research Center for two aircraft fuselage structures: a generic "aluminum testbed cylinder" (ATC) and a Beechcraft Starship fuselage (BSF). Subsequent acoustic tests will measure the interior noise field created by exterior mechanical and acoustic sources. These test results will provide validation databases for interior noise prediction codes on realistic aircraft fuselage structures. The ATC is a 12-ft-long, all-aluminum, scale model assembly. The BSF is a 40-ft-long, all-composite, complete aircraft fuselage. To date, two of seven test configurations of the ATC and all three test configurations of the BSF have been completed. The paper briefly describes the various test configurations, testing procedure, and typical results for frequencies up to 250 Hz.

  8. An improved EMD method for modal identification and a combined static-dynamic method for damage detection

    NASA Astrophysics Data System (ADS)

    Yang, Jinping; Li, Peizhen; Yang, Youfa; Xu, Dian

    2018-04-01

    Empirical mode decomposition (EMD) is a highly adaptable signal processing method. However, the EMD approach has certain drawbacks, including distortions from end effects and mode mixing. In the present study, these two problems are addressed using an end extension method based on the support vector regression machine (SVRM) and a modal decomposition method based on the characteristics of the Hilbert transform. The algorithm includes two steps: using the SVRM, the time series data are extended at both endpoints to reduce the end effects, and then, a modified EMD method using the characteristics of the Hilbert transform is performed on the resulting signal to reduce mode mixing. A new combined static-dynamic method for identifying structural damage is presented. This method combines the static and dynamic information in an equilibrium equation that can be solved using the Moore-Penrose generalized matrix inverse. The combination method uses the differences in displacements of the structure with and without damage and variations in the modal force vector. Tests on a four-story, steel-frame structure were conducted to obtain static and dynamic responses of the structure. The modal parameters are identified using data from the dynamic tests and improved EMD method. The new method is shown to be more accurate and effective than the traditional EMD method. Through tests with a shear-type test frame, the higher performance of the proposed static-dynamic damage detection approach, which can detect both single and multiple damage locations and the degree of the damage, is demonstrated. For structures with multiple damage, the combined approach is more effective than either the static or dynamic method. The proposed EMD method and static-dynamic damage detection method offer improved modal identification and damage detection, respectively, in structures.

  9. Experimental Modal Analysis and Dynaic Strain Fiber Bragg Gratings for Structural Health Monitoring of Composite Aerospace Structures

    NASA Astrophysics Data System (ADS)

    Panopoulou, A.; Fransen, S.; Gomez Molinero, V.; Kostopoulos, V.

    2012-07-01

    The objective of this work is to develop a new structural health monitoring system for composite aerospace structures based on dynamic response strain measurements and experimental modal analysis techniques. Fibre Bragg Grating (FBG) optical sensors were used for monitoring the dynamic response of the composite structure. The structural dynamic behaviour has been numerically simulated and experimentally verified by means of vibration testing. The hypothesis of all vibration tests was that actual damage in composites reduces their stiffness and produces the same result as mass increase produces. Thus, damage was simulated by slightly varying locally the mass of the structure at different zones. Experimental modal analysis based on the strain responses was conducted and the extracted strain mode shapes were the input for the damage detection expert system. A feed-forward back propagation neural network was the core of the damage detection system. The features-input to the neural network consisted of the strain mode shapes, extracted from the experimental modal analysis. Dedicated training and validation activities were carried out based on the experimental results. The system showed high reliability, confirmed by the ability of the neural network to recognize the size and the position of damage on the structure. The experiments were performed on a real structure i.e. a lightweight antenna sub- reflector, manufactured and tested at EADS CASA ESPACIO. An integrated FBG sensor network, based on the advantage of multiplexing, was mounted on the structure with optimum topology. Numerical simulation of both structures was used as a support tool at all the steps of the work. Potential applications for the proposed system are during ground qualification extensive tests of space structures and during the mission as modal analysis tool on board, being able via the FBG responses to identify a potential failure.

  10. Build-Up Approach to Updating the Mock Quiet Spike Beam Model

    NASA Technical Reports Server (NTRS)

    Herrera, Claudia Y.; Pak, Chan-gi

    2007-01-01

    When a new aircraft is designed or a modification is done to an existing aircraft, the aeroelastic properties of the aircraft should be examined to ensure the aircraft is flight worthy. Evaluating the aeroelastic properties of a new or modified aircraft can include performing a variety of analyses, such as modal and flutter analyses. In order to produce accurate results from these analyses, it is imperative to work with finite element models (FEM) that have been validated by or correlated to ground vibration test (GVT) data, Updating an analytical model using measured data is a challenge in the area of structural dynamics. The analytical model update process encompasses a series of optimizations that match analytical frequencies and mode shapes to the measured modal characteristics of structure. In the past, the method used to update a model to test data was "trial and error." This is an inefficient method - running a modal analysis, comparing the analytical results to the GVT data, manually modifying one or more structural parameters (mass, CG, inertia, area, etc.), rerunning the analysis, and comparing the new analytical modal characteristics to the GVT modal data. If the match is close enough (close enough defined by analyst's updating requirements), then the updating process is completed. If the match does not meet updating-requirements, then the parameters are changed again and the process is repeated. Clearly, this manual optimization process is highly inefficient for large FEM's and/or a large number of structural parameters. NASA Dryden Flight Research Center (DFRC) has developed, in-house, a Mode Matching Code that automates the above-mentioned optimization process, DFRC's in-house Mode Matching Code reads mode shapes and frequencies acquired from GVT to create the target model. It also reads the current analytical model, as we11 as the design variables and their upper and lower limits. It performs a modal analysis on this model and modifies it to create an updated model that has similar mode shapes and frequencies as those of the target model. The Mode Matching Code output frequencies and modal assurance criteria (MAC) values that allow for the quantified comparison of the updated model versus the target model. A recent application of this code is the F453 supersonic flight testing platform, NASA DFRC possesses a modified F-15B that is used as a test bed aircraft for supersonic flight experiments. Traditionally, the finite element model of the test article is generated. A GVT is done on the test article ta validate and update its FEM. This FEM is then mated to the F-15B model, which was correlated to GVT data in fall of 2004, A GVT is conducted with the test article mated to the aircraft, and this mated F-15B/ test article FEM is correlated to this final GVT.

  11. P05.05. A Multidisciplinary Approach to Hypertension: Yes We Can!

    PubMed Central

    Cheng, Catherine; Burns, Virginia; Southard, Carol; Silberg, Aline; Crowley, Maggie; Feldman, Howard; Meyer, Mary Anne

    2013-01-01

    Focus Area: Integrative Approaches to Care Hypertension is one of the most common chronic diseases in our nation, affecting approximately 75 million adults, according to the American Heart Association. Data from the JNC-7 in 2003 demonstrated that about two-thirds of those individuals who are being treated with conventional antihypertensive agents did not have their blood pressure under control. Thus, there is a clear need for a complementary and integrative approach to fill in the gaps left by conventional medicine in the treatment of hypertension. In addition, many patients either cannot tolerate conventional antihypertensive medications or are more interested in trying other types of treatments to help control their blood pressure. There are myriad complementary and integrative approaches used for antihypertensive effects, and it is beneficial for practitioners to be aware of the available options. But beyond simply knowing about the choices they have to help their patients manage their hypertension, it is also important for providers to know what evidence exists for the different modalities in order to help direct their patients to make the best choices for their own overall health. The poster presentation will address segments on integrative treatment approaches for hypertension that will include (1) acupuncture and traditional Chinese medicine; (2) tobacco cessation; (3) massage therapy; (4) mindfulness meditation; (5) qi gong; and (6) overall lifestyle change—diet, exercise, and supplements. For most of the individual segments, there will be demonstrations of techniques to be done either with the group as a whole or with individual volunteers. The presenter will discuss the available research for each of the treatment modalities as well as the types of patients who might respond well to specific types of treatment.

  12. Diagnostic imaging in paraneoplastic autoimmune multiorgan syndrome: retrospective single site study and literature review of 225 patients.

    PubMed

    Lehman, Vance T; Barrick, Benjamin J; Pittelkow, Mark R; Peller, Patrick J; Camilleri, Michael J; Lehman, Julia S

    2015-04-01

    The utility of diagnostic imaging in paraneoplastic autoimmune multiorgan syndrome (PAMS) is unknown. We examined the role of diagnostic imaging in patients with PAMS evaluated at our tertiary referral center (at Mayo Clinic, Rochester, MN, USA) and in the English literature between January 1, 1996, and August 31, 2012. We included 17 patients from our institution and 208 patients from the literature review. Of these 225 patients, 113 (50.2%) were not known to have a malignancy diagnosis at the time of PAMS diagnosis. Of the 123 patients from our institution and from the literature reported to undergo imaging studies, conventional computed tomography (CT) was the predominant imaging modality (n = 110; 89.4%); 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/CT was also used, albeit infrequently (n = 12; 9.8%). When CT was included in imaging to identify or confirm the presence of a malignancy, imaging was successful in all patients who ultimately were diagnosed with an associated malignancy. At our institution, a relatively high percentage (n = 7; 41%) of patients had 18F-FDG PET/CT, which not only identified all tumors found on CT but also facilitated staging of lymphoma and guided biopsy procedures. Diagnostic imaging is frequently utilized in PAMS with unknown malignancy. Both conventional CT and 18F-FDG PET/CT are likely to detect the typical underlying neoplasms. Relative to conventional CT, 18F-FDG PET/CT may provide additional useful information regarding prognosis for the likely underlying malignancies, although there is a paucity of reports describing the use of this modality for this purpose. © 2014 The International Society of Dermatology.

  13. Combination Treatment of Glioblastoma by Low-Dose Radiation and Genistein.

    PubMed

    Atefeh, Zamanian; Vahid, Changizi; Hasan, Nedaie; Saeed, Amanpour; Mahnaz, Haddadi

    2016-01-01

    Gioblastoma multiforme as a chemoresistant and radioresistant malignant cell line needs to novel strategies to treatment. Low-dose hyper-radiosensitivity (LDHRS) seems to be an effective phenomenon to irradiation that can save normal brain fibroblasts. Genistein which is a soy isoflavone can be cytotoxic in some tumor cell lines. So we determined to study the effect of combining these two treatment modalities. After 30 hours incubation with Genistein in different concentrations on U87MG cell line, proliferation and clonogenicity were conducted by both clonogenic and MTT assays. A conventional 2Gy radiation dose was compared with 10 doses of 0.2Gy gamma irradiation with 3 minutes and 1 hour intervals. Finally, concurrent effect of these modalities was assessed. Based on acquired cell doubling time (30 hours), one doubling time treatment by Genistein could decrease clonogenicity. U87MG cell line exhibited HRS at low dose irradiations. 2Gy irradiation was more effective than ultra-fractionation methods in comparison with control group. All groups with 50uM concentration of Genistein showed decrease in the survival. This decrease compared with control group, in 10x0.2Gy with 3 minutes intervals plus 50uM Genistein was significant and for groups with the same dose of Genistein but along with continuous 2Gy was more significant. In one day treatment regimen, 10x0.2Gy ultra-fractionation with 3 minutes and 1 hour intervals seems to be less effective than conventional 2Gy irradiation, however adding 50uM Genistein can decrease survival more. Although 2Gy conventional dose plus 50uM Genistein was the most effective regimen. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  14. Web-Assisted Vocational Test Interpretation.

    ERIC Educational Resources Information Center

    Jones, W. Paul; Harbach, Robert L.; Coker, J. Kelly; Staples, Pamela A.

    2002-01-01

    Compares the effectiveness of a specific employment counseling activity, vocational interest inventory interpretation, across 3 delivery modalities: online text chat; online text chat with video cues; and traditional face-to-face interpretation. The difference in ratings of session value between text chat and video and face-to-face modalities was…

  15. Crossmodal Statistical Binding of Temporal Information and Stimuli Properties Recalibrates Perception of Visual Apparent Motion

    PubMed Central

    Zhang, Yi; Chen, Lihan

    2016-01-01

    Recent studies of brain plasticity that pertain to time perception have shown that fast training of temporal discrimination in one modality, for example, the auditory modality, can improve performance of temporal discrimination in another modality, such as the visual modality. We here examined whether the perception of visual Ternus motion could be recalibrated through fast crossmodal statistical binding of temporal information and stimuli properties binding. We conducted two experiments, composed of three sessions each: pre-test, learning, and post-test. In both the pre-test and the post-test, participants classified the Ternus display as either “element motion” or “group motion.” For the training session in Experiment 1, we constructed two types of temporal structures, in which two consecutively presented sound beeps were dominantly (80%) flanked by one leading visual Ternus frame and by one lagging visual Ternus frame (VAAV) or dominantly inserted by two Ternus visual frames (AVVA). Participants were required to respond which interval (auditory vs. visual) was longer. In Experiment 2, we presented only a single auditory–visual pair but with similar temporal configurations as in Experiment 1, and asked participants to perform an audio–visual temporal order judgment. The results of these two experiments support that statistical binding of temporal information and stimuli properties can quickly and selectively recalibrate the sensitivity of perceiving visual motion, according to the protocols of the specific bindings. PMID:27065910

  16. A neuropsychoanalytical approach to the hard problem of consciousness.

    PubMed

    Solms, Mark

    2014-06-01

    A neuropsychoanalytical approach to the hard problem of consciousness revolves around the distinction between the subject of consciousness and objects of consciousness. In contrast to the mainstream of cognitive science, neuropsychoanalysis prioritizes the subject. The subject of consciousness is the indispensable page upon which consciousness of objects is inscribed. This has implications for our conception of the mental. The subjective being of consciousness is not registered in the classical exteroceptive modalities; it is not merely a cognitive representation, not only a memory trace. Rather, the exteroceptive modalities are registered in the subjective being. Cognitive representations are mental solids embedded within subjectivity, the tangible and visible (etc) properties of which are projected onto reality. It is important to recognize that mental solids (e.g., the body-as-object) are no more real than the subjective being they are inscribed in (the body-as-subject). Moreover, pure subjectivity is not without content or quality. This aspect of consciousness is conventionally described quantitatively as the level of consciousness, or wakefulness. But it feels like something to be awake. The primary modality of this aspect of consciousness is affect. Affect supplies the subjectivity that underpins all consciousness. Some implications of this approach are discussed here, in broad brush strokes.

  17. Comparison of unsupervised classification methods for brain tumor segmentation using multi-parametric MRI.

    PubMed

    Sauwen, N; Acou, M; Van Cauter, S; Sima, D M; Veraart, J; Maes, F; Himmelreich, U; Achten, E; Van Huffel, S

    2016-01-01

    Tumor segmentation is a particularly challenging task in high-grade gliomas (HGGs), as they are among the most heterogeneous tumors in oncology. An accurate delineation of the lesion and its main subcomponents contributes to optimal treatment planning, prognosis and follow-up. Conventional MRI (cMRI) is the imaging modality of choice for manual segmentation, and is also considered in the vast majority of automated segmentation studies. Advanced MRI modalities such as perfusion-weighted imaging (PWI), diffusion-weighted imaging (DWI) and magnetic resonance spectroscopic imaging (MRSI) have already shown their added value in tumor tissue characterization, hence there have been recent suggestions of combining different MRI modalities into a multi-parametric MRI (MP-MRI) approach for brain tumor segmentation. In this paper, we compare the performance of several unsupervised classification methods for HGG segmentation based on MP-MRI data including cMRI, DWI, MRSI and PWI. Two independent MP-MRI datasets with a different acquisition protocol were available from different hospitals. We demonstrate that a hierarchical non-negative matrix factorization variant which was previously introduced for MP-MRI tumor segmentation gives the best performance in terms of mean Dice-scores for the pathologic tissue classes on both datasets.

  18. Energy-weighted dynamical scattering simulations of electron diffraction modalities in the scanning electron microscope.

    PubMed

    Pascal, Elena; Singh, Saransh; Callahan, Patrick G; Hourahine, Ben; Trager-Cowan, Carol; Graef, Marc De

    2018-04-01

    Transmission Kikuchi diffraction (TKD) has been gaining momentum as a high resolution alternative to electron back-scattered diffraction (EBSD), adding to the existing electron diffraction modalities in the scanning electron microscope (SEM). The image simulation of any of these measurement techniques requires an energy dependent diffraction model for which, in turn, knowledge of electron energies and diffraction distances distributions is required. We identify the sample-detector geometry and the effect of inelastic events on the diffracting electron beam as the important factors to be considered when predicting these distributions. However, tractable models taking into account inelastic scattering explicitly are lacking. In this study, we expand the Monte Carlo (MC) energy-weighting dynamical simulations models used for EBSD [1] and ECP [2] to the TKD case. We show that the foil thickness in TKD can be used as a means of energy filtering and compare band sharpness in the different modalities. The current model is shown to correctly predict TKD patterns and, through the dictionary indexing approach, to produce higher quality indexed TKD maps than conventional Hough transform approach, especially close to grain boundaries. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  19. State-of-the-art: Radiological investigation of pleural disease.

    PubMed

    Hallifax, R J; Talwar, A; Wrightson, J M; Edey, A; Gleeson, F V

    2017-03-01

    Pleural disease is common. Radiological investigation of pleural effusion, thickening, masses, and pneumothorax is key in diagnosing and determining management. Conventional chest radiograph (CXR) remains as the initial investigation of choice for patients with suspected pleural disease. When abnormalities are detected, thoracic ultrasound (US), computed tomography (CT), magnetic resonance imaging (MRI) and positron emission tomography (PET) can each play important roles in further investigation, but appropriate modality selection is critical. US adds significant value in the identification of pleural fluid and pleural nodularity, guiding pleural procedures and, increasingly, as "point of care" assessment for pneumothorax, but is highly operator dependent. CT scan is the modality of choice for further assessment of pleural disease: Characterising pleural thickening, some pleural effusions and demonstration of homogeneity of pleural masses and areas of fatty attenuation or calcification. MRI has specific utility for soft tissue abnormalities and may have a role for younger patients requiring follow-up serial imaging. MRI and PET/CT may provide additional information in malignant pleural disease regarding prognosis and response to therapy. This article summarises existing techniques, highlighting the benefits and applications of these different imaging modalities and provides an up to date review of the evidence. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Patients at Risk for Peritoneal Surface Malignancy of Colorectal Cancer Origin: The Role of Second Look Laparotomy

    PubMed Central

    Brücher, Björn LDM; Stojadinovic, Alexander; Bilchik, Anton J.; Protic, Mladjan; Daumer, Martin; Nissan, Aviram; Avital, Itzhak

    2013-01-01

    Peritoneal surface malignancy (PSM) is a frequent occurrence in the natural history of colorectal cancer (CRC). Although significant advances have been made in screening of CRC, similar progress has yet to be made in the early detection of PSM of colorectal cancer origin. The fact that advanced CRC can be confined to the peritoneal surface without distant dissemination forms the basis for aggressive multi-modality therapy consisting of cytoreductive surgery (CRS) plus hyperthermic intra-peritoneal chemotherapy (HIPEC), and neoadjuvant and/or adjuvant systemic therapy. Reported overall survival with complete CRS+HIPEC exceeds that of systemic therapy alone for the treatment of PSM from CRC, underscoring the advantage of this multi-modality therapeutic approach. Patients with limited peritoneal disease from CRC can undergo complete cytoreduction, which is associated with the best reported outcomes. As early or limited peritoneal carcinomatosis is undetectable by conventional imaging modalities, second look laparotomy is an important means to identify disease in high-risk patients at a stage most amenable to complete cytoreduction. This review focuses on the identification of patients at risk for PSM from CRC and discusses the role of second look laparotomy. PMID:23459716

  1. Relationship of Various Open Quotients With Acoustic Property, Phonation Types, Fundamental Frequency, and Intensity.

    PubMed

    Yokonishi, Hisayuki; Imagawa, Hiroshi; Sakakibara, Ken-Ichi; Yamauchi, Akihito; Nito, Takaharu; Yamasoba, Tatsuya; Tayama, Niro

    2016-03-01

    In the present study, we examined the relationship between various open quotients (Oqs) and phonation types, fundamental frequency (F0), and intensity by multivariate linear regression analysis (MVA) to determine which Oq best reflects vocal fold vibratory characteristics. Using high-speed digital imaging (HSDI), a sustained vowel /e/ at different phonation types, F0s, and intensities was recorded from six vocally healthy male volunteers: the types of phonation included modal, falsetto, modal breathy, and modal pressed phonations; and each phonation was performed at different F0s and intensities. Electroglottography (EGG) and sound signals were simultaneously recorded with HSDI. From the obtained data, 10 conventional Oqs (four Oqs from the glottal area function, four kymographic Oqs, and two EGG-derived Oqs) and two newly introduced Oqs (Oq(edge)+ and Oq(edge)) were evaluated. And, relationships between various Oqs and phonation types, F0, and intensity were evaluated by MVA. Among the various Oqs, Oq(edge)+ and Oq(edge) revealed the strongest correlations with an acoustic property and could best describe changes in phonation types: Oq(edge) was found to be better than Oq(edge)¯. Oq(MLK), the average of five Oqs from five-line multiline kymography was a very good alternative to Oq(edge)¯. EGG-derived Oqs were able to differentiate between modal phonation and falsetto phonation, but it was necessary to consider the change of F0 simultaneously. MVA showed the changes in Oq values between modal and other phonation types, the degree of involvement of intensity, and no relationship between F0 and Oqs. Among Oqs evaluated in this study, Oq(edge)+ and Oq(edge) were considered to best reflect the vocal fold vibratory characteristics. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  2. Are there differential symptom profiles that improve in response to different pharmacological treatments of premenstrual syndrome/premenstrual dysphoric disorder?

    PubMed

    Halbreich, Uriel; O'Brien, P M Shaughn; Eriksson, Elias; Bäckström, Torbjörn; Yonkers, Kimberly A; Freeman, Ellen W

    2006-01-01

    Current evidence suggests that the accepted treatments for premenstrual syndrome (PMS)/premenstrual dysphoric disorder (PMDD) have similar overall efficacy. While these treatments are more effective than placebo, response rates associated with them are far from satisfactory (<60%), such that, irrespective of treatment modality, there remain a significant number of women who are unresponsive to current conventional pharmacological therapy. The available data on response rates of specific types of premenstrual symptoms to, or symptom profiles that are most amenable to, each treatment modality are limited and not well defined because most studies were not designed to assess specific symptom profiles. Those studies that have attempted to evaluate which symptom profiles respond to specific therapies have revealed variations within the individual modalities, as well as between the different modalities. It appears that suppression of ovulation ameliorates a broad range of behavioural as well as physical premenstrual symptoms. SSRIs are most effective for irritability and anxiety symptoms, with lesser efficacy for 'atypical' premenstrual symptoms. GABAergic compounds are most efficacious for anxiety and anxious/depressive symptoms, while dopamine agonists, particularly bromocriptine, are perhaps most efficacious for mastalgia. Overall treatment response rates may improve if treatments are targeted at well-defined subgroups of patients. Re-analysis of available datasets from randomised clinical trials may shed more light on the notion that targeting women with specific premenstrual symptom profiles for specific treatment modalities would improve response rates beyond the current ceiling of approximately 60%. Such information would also improve understanding of the putative pathophysiological mechanisms underlying PMS and PMDD, and may point to a more specific diagnosis of these conditions.

  3. Contrast-enhanced [18F] fluorodeoxyglucose-positron emission tomography-computed tomography as an initial imaging modality in patients presenting with metastatic malignancy of undefined primary origin.

    PubMed

    Jain, Avani; Srivastava, Madhur Kumar; Pawaskar, Alok Suresh; Shelley, Simon; Elangovan, Indirani; Jain, Hasmukh; Pandey, Somnath; Kalal, Shilpa; Amalachandran, Jaykanth

    2015-01-01

    To evaluate the advantages of contrast enhanced F-18-fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-contrast enhanced CT [CECT]) when used as an initial imaging modality in patients presenting with metastatic malignancy of undefined primary origin (MUO). A total of 243 patients with fine needle aspiration cytology/biopsy proven MUO were included in this prospective study. Patients who were thoroughly evaluated for primary or primary tumor was detected by any other investigation were excluded from the analysis. Totally, 163 patients with pathological diagnosis of malignancy but no apparent sites of the primary tumor were finally selected for analysis. The site of probable primary malignancy suggested by PET-CECT was confirmed by biopsy/follow-up. PET-CECT suggested probable site of primary in 128/163 (78.52%) patients. In 30/35 remaining patients, primary tumor was not detected even after extensive work-up. In 5 patients, where PET-CECT was negative, primary was found on further extensive investigations or follow-up. The sensitivity, specificity, positive predictive value and negative predictive value of the study were 95.76%, 66.67%, 88.28% and 85.71% respectively. F-18 FDG PET-CECT aptly serves the purpose of initial imaging modality owing to high sensitivity, negative and positive predictive value. PET-CECT not only surveys the whole body for the primary malignancy but also stages the disease accurately. Use of contrast improves the diagnostic utility of modality as well as help in staging of the primary tumor. Although benefits of using PET-CECT as initial diagnostic modality are obvious from this study, there is a need for a larger study comparing conventional methods for diagnosing primary in patients with MUO versus PET-CECT.

  4. Increasing Nutrition Literacy: Testing the Effectiveness of Print, Web Site, and Game Modalities

    ERIC Educational Resources Information Center

    Silk, Kami J.; Sherry, John; Winn, Brian; Keesecker, Nicole; Horodynski, Mildred A.; Sayir, Aylin

    2008-01-01

    Objective: To examine the effectiveness of three modalities for delivery of nutrition education. Design: Between-subjects, repeated-measures design. Setting: Data were collected at community agencies or during home visits. Participants: Low-income, European American and African American mothers (N = 155). Intervention: Participants were exposed to…

  5. Explicit Processing Demands Reveal Language Modality-Specific Organization of Working Memory

    ERIC Educational Resources Information Center

    Rudner, Mary; Ronnberg, Jerker

    2008-01-01

    The working memory model for Ease of Language Understanding (ELU) predicts that processing differences between language modalities emerge when cognitive demands are explicit. This prediction was tested in three working memory experiments with participants who were Deaf Signers (DS), Hearing Signers (HS), or Hearing Nonsigners (HN). Easily nameable…

  6. Research Problems Associated with Limiting the Applied Force in Vibration Tests and Conducting Base-Drive Modal Vibration Tests

    NASA Technical Reports Server (NTRS)

    Scharton, Terry D.

    1995-01-01

    The intent of this paper is to make a case for developing and conducting vibration tests which are both realistic and practical (a question of tailoring versus standards). Tests are essential for finding things overlooked in the analyses. The best test is often the most realistic test which can be conducted within the cost and budget constraints. Some standards are essential, but the author believes more in the individual's ingenuity to solve a specific problem than in the application of standards which reduce problems (and technology) to their lowest common denominator. Force limited vibration tests and base-drive modal tests are two examples of realistic, but practical testing approaches. Since both of these approaches are relatively new, a number of interesting research problems exist, and these are emphasized herein.

  7. Temporal and modal characterization of DoD source air toxic ...

    EPA Pesticide Factsheets

    This project tested three, real-/near real-time monitoring techniques to develop air toxic emission factors for Department of Defense (DoD) platform sources. These techniques included: resonance enhanced multi photon ionization time of flight mass spectrometry (REMPI-TOFMS) for organic air toxics, laser induced breakdown spectroscopy (LIBS) for metallic air toxics, and optical remote sensing (ORS) methods for measurement of criteria pollutants and other hazardous air pollutants (HAPs). Conventional emission measurements were used for verification of the real-time monitoring results. The REMPI-TOFMS system was demonstrated on the following: --a United States U.S. Marine Corps (USMC) diesel generator, --a U.S. Air Force auxiliary power unit (APU), --the waste combustor at the Portsmouth Naval Shipyard, during a multi-monitor environmental technology verification (ETV) test for dioxin monitoring systems, --two dynamometer-driven high mobility multi-purpose wheeled vehicles (HMMWVs), --an idling Abrams battle tank, --a Bradley infantry fighting vehicle (IFV), and --an F-15 and multiple F-22 U.S. Air Force aircraft engines. LIBS was tested and applied solely to the U.S. Marine Corps diesel generator. The high detection limits of LIBS for toxic metals limited its usefulness as a real time analyzer for most DoD sources. ORS was tested only on the APU with satisfactory results for non-condensable combustion products (carbon monoxide [CO], carbon dioxide

  8. Modal Identification in an Automotive Multi-Component System Using HS 3D-DIC

    PubMed Central

    López-Alba, Elías; Felipe-Sesé, Luis; Díaz, Francisco A.

    2018-01-01

    The modal characterization of automotive lighting systems becomes difficult using sensors due to the light weight of the elements which compose the component as well as the intricate access to allocate them. In experimental modal analysis, high speed 3D digital image correlation (HS 3D-DIC) is attracting the attention since it provides full-field contactless measurements of 3D displacements as main advantage over other techniques. Different methodologies have been published that perform modal identification, i.e., natural frequencies, damping ratios, and mode shapes using the full-field information. In this work, experimental modal analysis has been performed in a multi-component automotive lighting system using HS 3D-DIC. Base motion excitation was applied to simulate operating conditions. A recently validated methodology has been employed for modal identification using transmissibility functions, i.e., the transfer functions from base motion tests. Results make it possible to identify local and global behavior of the different elements of injected polymeric and metallic materials. PMID:29401725

  9. An automatic data system for vibration modal tuning and evaluation

    NASA Technical Reports Server (NTRS)

    Salyer, R. A.; Jung, E. J., Jr.; Huggins, S. L.; Stephens, B. L.

    1975-01-01

    A digitally based automatic modal tuning and analysis system developed to provide an operational capability beginning at 0.1 hertz is described. The elements of the system, which provides unique control features, maximum operator visibility, and rapid data reduction and documentation, are briefly described; and the operational flow is discussed to illustrate the full range of capabilities and the flexibility of application. The successful application of the system to a modal survey of the Skylab payload is described. Information about the Skylab test article, coincident-quadrature analysis of modal response data, orthogonality, and damping calculations is included in the appendixes. Recommendations for future application of the system are also made.

  10. Abdominal hernias: Radiological features

    PubMed Central

    Lassandro, Francesco; Iasiello, Francesca; Pizza, Nunzia Luisa; Valente, Tullio; Stefano, Maria Luisa Mangoni di Santo; Grassi, Roberto; Muto, Roberto

    2011-01-01

    Abdominal wall hernias are common diseases of the abdomen with a global incidence approximately 4%-5%. They are distinguished in external, diaphragmatic and internal hernias on the basis of their localisation. Groin hernias are the most common with a prevalence of 75%, followed by femoral (15%) and umbilical (8%). There is a higher prevalence in males (M:F, 8:1). Diagnosis is usually made on physical examination. However, clinical diagnosis may be difficult, especially in patients with obesity, pain or abdominal wall scarring. In these cases, abdominal imaging may be the first clue to the correct diagnosis and to confirm suspected complications. Different imaging modalities are used: conventional radiographs or barium studies, ultrasonography and Computed Tomography. Imaging modalities can aid in the differential diagnosis of palpable abdominal wall masses and can help to define hernial contents such as fatty tissue, bowel, other organs or fluid. This work focuses on the main radiological findings of abdominal herniations. PMID:21860678

  11. Multicolor Scanning Laser Imaging in Diabetic Retinopathy.

    PubMed

    Ahmad, Mohammad S Z; Carrim, Zia Iqbal

    2017-11-01

    Diabetic retinopathy is a common cause of blindness in individuals younger than 60 years. Screening for retinopathy is undertaken using conventional color fundus photography and relies on the identification of hemorrhages, vascular abnormalities, exudates, and cotton-wool spots. These can sometimes be difficult to identify. Multicolor scanning laser imaging, a new imaging modality, may have a role in improving screening outcomes, as well as facilitating treatment decisions. Observational case series comprising two patients with known diabetes who were referred for further examination after color fundus photography revealed abnormal findings. Multicolor scanning laser imaging was undertaken. Features of retinal disease from each modality were compared. Multicolor scanning laser imaging provides superior visualization of retinal anatomy and pathology, thereby facilitating risk stratification and treatment decisions. Multicolor scanning laser imaging is a novel imaging technique offering the potential for improving the reliability of screening for diabetic retinopathy. Validation studies are warranted.

  12. Tracked 3D ultrasound in radio-frequency liver ablation

    NASA Astrophysics Data System (ADS)

    Boctor, Emad M.; Fichtinger, Gabor; Taylor, Russell H.; Choti, Michael A.

    2003-05-01

    Recent studies have shown that radio frequency (RF) ablation is a simple, safe and potentially effective treatment for selected patients with liver metastases. Despite all recent therapeutic advancements, however, intra-procedural target localization and precise and consistent placement of the tissue ablator device are still unsolved problems. Various imaging modalities, including ultrasound (US) and computed tomography (CT) have been tried as guidance modalities. Transcutaneous US imaging, due to its real-time nature, may be beneficial in many cases, but unfortunately, fails to adequately visualize the tumor in many cases. Intraoperative or laparoscopic US, on the other hand, provides improved visualization and target imaging. This paper describes a system for computer-assisted RF ablation of liver tumors, combining navigational tracking of a conventional imaging ultrasound probe to produce 3D ultrasound imaging with a tracked RF ablation device supported by a passive mechanical arm and spatially registered to the ultrasound volume.

  13. Tailorable stimulated Brillouin scattering in nanoscale silicon waveguides.

    PubMed

    Shin, Heedeuk; Qiu, Wenjun; Jarecki, Robert; Cox, Jonathan A; Olsson, Roy H; Starbuck, Andrew; Wang, Zheng; Rakich, Peter T

    2013-01-01

    Nanoscale modal confinement is known to radically enhance the effect of intrinsic Kerr and Raman nonlinearities within nanophotonic silicon waveguides. By contrast, stimulated Brillouin-scattering nonlinearities, which involve coherent coupling between guided photon and phonon modes, are stifled in conventional nanophotonics, preventing the realization of a host of Brillouin-based signal-processing technologies in silicon. Here we demonstrate stimulated Brillouin scattering in silicon waveguides, for the first time, through a new class of hybrid photonic-phononic waveguides. Tailorable travelling-wave forward-stimulated Brillouin scattering is realized-with over 1,000 times larger nonlinearity than reported in previous systems-yielding strong Brillouin coupling to phonons from 1 to 18 GHz. Experiments show that radiation pressures, produced by subwavelength modal confinement, yield enhancement of Brillouin nonlinearity beyond those of material nonlinearity alone. In addition, such enhanced and wideband coherent phonon emission paves the way towards the hybridization of silicon photonics, microelectromechanical systems and CMOS signal-processing technologies on chip.

  14. [18F-Fluorocholine PET-CT for localization of parathyroid adenomas].

    PubMed

    Kluijfhout, Wouter P; Vriens, Menno R; Borel Rinkes, Inne H M; Valk, Gerlof D; de Klerk, John M H; de Keizer, Bart

    2015-01-01

    18F-fluorocholine PET-CT is a new imaging modality for the localization of pathological parathyroid glands in patients with primary hyperparathyroidism. The PET-CT is a combination scan that uses both the physiological information from the PET and the anatomical information from the CT. Uptake of the radio-isotope 18F-fluorocholine is increased in pathological parathyroid glands. 18F-fluorocholine PET-CT helps clinicians to localize the pathological parathyroid glands where conventional modalities fail to do so. This enables surgeons to carry out targeted minimal invasive surgery. It may also prevent the patient having to undergo a more extensive exploration, with its associated risks, and alleviate the necessity of taking medications with side effects. Although the literature on this subject is still scarce, preliminary results are promising. As any hospital with a PET-CT can perform the scan, we expect that its use in patients with hyperparathyroidism will increase over the next few years.

  15. Optimal control of large space structures via generalized inverse matrix

    NASA Technical Reports Server (NTRS)

    Nguyen, Charles C.; Fang, Xiaowen

    1987-01-01

    Independent Modal Space Control (IMSC) is a control scheme that decouples the space structure into n independent second-order subsystems according to n controlled modes and controls each mode independently. It is well-known that the IMSC eliminates control and observation spillover caused when the conventional coupled modal control scheme is employed. The independent control of each mode requires that the number of actuators be equal to the number of modelled modes, which is very high for a faithful modeling of large space structures. A control scheme is proposed that allows one to use a reduced number of actuators to control all modeled modes suboptimally. In particular, the method of generalized inverse matrices is employed to implement the actuators such that the eigenvalues of the closed-loop system are as closed as possible to those specified by the optimal IMSC. Computer simulation of the proposed control scheme on a simply supported beam is given.

  16. Theory and preliminary experimental verification of quantitative edge illumination x-ray phase contrast tomography.

    PubMed

    Hagen, C K; Diemoz, P C; Endrizzi, M; Rigon, L; Dreossi, D; Arfelli, F; Lopez, F C M; Longo, R; Olivo, A

    2014-04-07

    X-ray phase contrast imaging (XPCi) methods are sensitive to phase in addition to attenuation effects and, therefore, can achieve improved image contrast for weakly attenuating materials, such as often encountered in biomedical applications. Several XPCi methods exist, most of which have already been implemented in computed tomographic (CT) modality, thus allowing volumetric imaging. The Edge Illumination (EI) XPCi method had, until now, not been implemented as a CT modality. This article provides indications that quantitative 3D maps of an object's phase and attenuation can be reconstructed from EI XPCi measurements. Moreover, a theory for the reconstruction of combined phase and attenuation maps is presented. Both reconstruction strategies find applications in tissue characterisation and the identification of faint, weakly attenuating details. Experimental results for wires of known materials and for a biological object validate the theory and confirm the superiority of the phase over conventional, attenuation-based image contrast.

  17. Integrative Tumor Board: a Case Report and Discussion from Dana-Farber Cancer Institute

    PubMed Central

    Lu, Weidong; Ott, Mary Jane; Kennedy, Stacy; Mathay, Maria B.; Doherty-Gilman, Anne M.; Dean-Clower, Elizabeth; Hayes, Carolyn M.; Rosenthal, David S.

    2010-01-01

    A 34-year-old female carrying a BRCA1 gene and a significant family history was diagnosed with T1c, N1 breast cancer. The tumor was estrogen receptor, progesterone receptor and HER-2/Neu negative. The patient received dose-dense chemotherapy with Adriamycin and Cytoxan followed by Taxol, and left breast irradiation. Later, a bilateral S-GAP flap reconstruction with right prophylactic mastectomy and left mastectomy were performed. During her treatment, the patient had an integrative medicine consultation and was seen by a team of healthcare providers specializing in integrative therapies including integrative nutrition, therapeutic massage, acupuncture, and yoga. Each modality contributed unique benefit in her care that led to a satisfactory outcome of the patient. A detailed discussion regarding her care from each modality is presented. The case elucidates the need of integrative approaches for cancer patients in a conventional medical setting. PMID:19815593

  18. A brain-controlled lower-limb exoskeleton for human gait training.

    PubMed

    Liu, Dong; Chen, Weihai; Pei, Zhongcai; Wang, Jianhua

    2017-10-01

    Brain-computer interfaces have been a novel approach to translate human intentions into movement commands in robotic systems. This paper describes an electroencephalogram-based brain-controlled lower-limb exoskeleton for gait training, as a proof of concept towards rehabilitation with human-in-the-loop. Instead of using conventional single electroencephalography correlates, e.g., evoked P300 or spontaneous motor imagery, we propose a novel framework integrated two asynchronous signal modalities, i.e., sensorimotor rhythms (SMRs) and movement-related cortical potentials (MRCPs). We executed experiments in a biologically inspired and customized lower-limb exoskeleton where subjects (N = 6) actively controlled the robot using their brain signals. Each subject performed three consecutive sessions composed of offline training, online visual feedback testing, and online robot-control recordings. Post hoc evaluations were conducted including mental workload assessment, feature analysis, and statistics test. An average robot-control accuracy of 80.16% ± 5.44% was obtained with the SMR-based method, while estimation using the MRCP-based method yielded an average performance of 68.62% ± 8.55%. The experimental results showed the feasibility of the proposed framework with all subjects successfully controlled the exoskeleton. The current paradigm could be further extended to paraplegic patients in clinical trials.

  19. A brain-controlled lower-limb exoskeleton for human gait training

    NASA Astrophysics Data System (ADS)

    Liu, Dong; Chen, Weihai; Pei, Zhongcai; Wang, Jianhua

    2017-10-01

    Brain-computer interfaces have been a novel approach to translate human intentions into movement commands in robotic systems. This paper describes an electroencephalogram-based brain-controlled lower-limb exoskeleton for gait training, as a proof of concept towards rehabilitation with human-in-the-loop. Instead of using conventional single electroencephalography correlates, e.g., evoked P300 or spontaneous motor imagery, we propose a novel framework integrated two asynchronous signal modalities, i.e., sensorimotor rhythms (SMRs) and movement-related cortical potentials (MRCPs). We executed experiments in a biologically inspired and customized lower-limb exoskeleton where subjects (N = 6) actively controlled the robot using their brain signals. Each subject performed three consecutive sessions composed of offline training, online visual feedback testing, and online robot-control recordings. Post hoc evaluations were conducted including mental workload assessment, feature analysis, and statistics test. An average robot-control accuracy of 80.16% ± 5.44% was obtained with the SMR-based method, while estimation using the MRCP-based method yielded an average performance of 68.62% ± 8.55%. The experimental results showed the feasibility of the proposed framework with all subjects successfully controlled the exoskeleton. The current paradigm could be further extended to paraplegic patients in clinical trials.

  20. Fast simulated annealing inversion of surface waves on pavement using phase-velocity spectra

    USGS Publications Warehouse

    Ryden, N.; Park, C.B.

    2006-01-01

    The conventional inversion of surface waves depends on modal identification of measured dispersion curves, which can be ambiguous. It is possible to avoid mode-number identification and extraction by inverting the complete phase-velocity spectrum obtained from a multichannel record. We use the fast simulated annealing (FSA) global search algorithm to minimize the difference between the measured phase-velocity spectrum and that calculated from a theoretical layer model, including the field setup geometry. Results show that this algorithm can help one avoid getting trapped in local minima while searching for the best-matching layer model. The entire procedure is demonstrated on synthetic and field data for asphalt pavement. The viscoelastic properties of the top asphalt layer are taken into account, and the inverted asphalt stiffness as a function of frequency compares well with laboratory tests on core samples. The thickness and shear-wave velocity of the deeper embedded layers are resolved within 10% deviation from those values measured separately during pavement construction. The proposed method may be equally applicable to normal soil site investigation and in the field of ultrasonic testing of materials. ?? 2006 Society of Exploration Geophysicists.

  1. Accuracy of digital arm and wrist manometers: clinical implications for the dental hygienist.

    PubMed

    Furgeson, Danielle; Mickels-Foster, Nancy

    2013-10-01

    Utilization of digital manometers chairside is fast becoming a standard of care in dental hygiene education. It is imperative to ensure accurate blood pressure measurements regardless of modality to avoid medical emergencies in the dental chair. This study sought to determine the accuracy of the automated digital arm and wrist cuffs utilized by students in the University of Maine at Augusta, Bangor Campus Dental Health Programs' dental hygiene clinic. After institutional review board approval, 121 subjects were recruited, with 21 excluded for a total of 100 subjects. Subjects were randomly assigned to different test modalities upon check-in. Initial blood pressure measurements were taken with a calibrated aneroid control device by a principal investigator. A second measurement was taken with the randomized arm or wrist manometer 5 minutes later. Investigators were blinded to the modality of test manometer and measurements obtained from the second reading. All readings were taken according to manufacturers' instructions to ensure technique consistency. Data indicated lower readings for each modality from the control for both systolic and diastolic measurements. The differences in the systolic and diastolic readings for the wrist modality were significantly lower than the control with (p= 0.000) and (p=0.000), respectively. Automated digital manometers should be used with caution as a screening tool in the dental setting, particularly when administration of pharmacological agents such as local anesthesia may be used during the course of treatment. These automated modalities should not be used for patients with cardiac or hypertensive conditions.

  2. Development of the "Treatment beliefs in knee and hip OsteoArthritis (TOA)" questionnaire.

    PubMed

    Selten, Ellen M H; Vriezekolk, Johanna E; Schers, Henk J; Nijhof, Marc W; van der Laan, Willemijn H; van der Meulen-Dilling, Roelien G; Geenen, Rinie; van den Ende, Cornelia H M

    2017-09-19

    Use of conservative treatment modalities in osteoarthritis (OA) is suboptimal, which appears to be partly due to patients' beliefs about treatments. The aim of this study was to develop a research instrument assessing patients' beliefs about various treatment modalities of hip and knee OA: the 'Treatment beliefs in OA (TOA) questionnaire'. The item pool that was retrieved from interviews with patients and healthcare providers comprised beliefs regarding five treatment modalities: physical activity, pain medication, physiotherapy, injections and arthroplasty. After an extensive selection procedure, a draft questionnaire with 200 items was constructed. Descriptive analyses and exploratory factor analyses with oblique rotation were conducted for each treatment modality separately to decide upon the final questionnaire. Internal consistency and test-retest reliability were determined. The final questionnaire comprised 60 items. It was completed by 351 patients with knee or hip OA. Each of the five treatment modalities yielded a two factor solution with 37% to 51% explained variance and high face validity. Factor I included 'positive treatment beliefs' and factor II 'negative treatment beliefs'. Internal consistency (Cronbach α's from 0.72 to 0.87) and test-retest reliability (i.e. intraclass correlation coefficient from 0.66-0.88; standard error of measurement from 0.06-0.11) were satisfactory to good. The TOA questionnaire is the first questionnaire assessing positive and negative treatment beliefs regarding five treatment modalities for knee and hip OA. The instrument will help to understand whether and to what extent treatment beliefs influence treatment choices.

  3. Depth measurements of drilled holes in bone by laser triangulation for the field of oral implantology

    NASA Astrophysics Data System (ADS)

    Quest, D.; Gayer, C.; Hering, P.

    2012-01-01

    Laser osteotomy is one possible method of preparing beds for dental implants in the human jaw. A major problem in using this contactless treatment modality is the lack of haptic feedback to control the depth while drilling the implant bed. A contactless measurement system called laser triangulation is presented as a new procedure to overcome this problem. Together with a tomographic picture the actual position of the laser ablation in the bone can be calculated. Furthermore, the laser response is sufficiently fast as to pose little risk to surrounding sensitive areas such as nerves and blood vessels. In the jaw two different bone structures exist, namely the cancellous bone and the compact bone. Samples of both bone structures were examined with test drillings performed either by laser osteotomy or by a conventional rotating drilling tool. The depth of these holes was measured using laser triangulation. The results and the setup are reported in this study.

  4. Validating Intravascular Imaging with Serial Optical Coherence Tomography and Confocal Fluorescence Microscopy.

    PubMed

    Tardif, Pier-Luc; Bertrand, Marie-Jeanne; Abran, Maxime; Castonguay, Alexandre; Lefebvre, Joël; Stähli, Barbara E; Merlet, Nolwenn; Mihalache-Avram, Teodora; Geoffroy, Pascale; Mecteau, Mélanie; Busseuil, David; Ni, Feng; Abulrob, Abedelnasser; Rhéaume, Éric; L'Allier, Philippe; Tardif, Jean-Claude; Lesage, Frédéric

    2016-12-15

    Atherosclerotic cardiovascular diseases are characterized by the formation of a plaque in the arterial wall. Intravascular ultrasound (IVUS) provides high-resolution images allowing delineation of atherosclerotic plaques. When combined with near infrared fluorescence (NIRF), the plaque can also be studied at a molecular level with a large variety of biomarkers. In this work, we present a system enabling automated volumetric histology imaging of excised aortas that can spatially correlate results with combined IVUS/NIRF imaging of lipid-rich atheroma in cholesterol-fed rabbits. Pullbacks in the rabbit aortas were performed with a dual modality IVUS/NIRF catheter developed by our group. Ex vivo three-dimensional (3D) histology was performed combining optical coherence tomography (OCT) and confocal fluorescence microscopy, providing high-resolution anatomical and molecular information, respectively, to validate in vivo findings. The microscope was combined with a serial slicer allowing for the imaging of the whole vessel automatically. Colocalization of in vivo and ex vivo results is demonstrated. Slices can then be recovered to be tested in conventional histology.

  5. Automatic colonic lesion detection and tracking in endoscopic videos

    NASA Astrophysics Data System (ADS)

    Li, Wenjing; Gustafsson, Ulf; A-Rahim, Yoursif

    2011-03-01

    The biology of colorectal cancer offers an opportunity for both early detection and prevention. Compared with other imaging modalities, optical colonoscopy is the procedure of choice for simultaneous detection and removal of colonic polyps. Computer assisted screening makes it possible to assist physicians and potentially improve the accuracy of the diagnostic decision during the exam. This paper presents an unsupervised method to detect and track colonic lesions in endoscopic videos. The aim of the lesion screening and tracking is to facilitate detection of polyps and abnormal mucosa in real time as the physician is performing the procedure. For colonic lesion detection, the conventional marker controlled watershed based segmentation is used to segment the colonic lesions, followed by an adaptive ellipse fitting strategy to further validate the shape. For colonic lesion tracking, a mean shift tracker with background modeling is used to track the target region from the detection phase. The approach has been tested on colonoscopy videos acquired during regular colonoscopic procedures and demonstrated promising results.

  6. Piezoelectric paints as one approach to smart structural materials with health-monitoring capabilities

    NASA Astrophysics Data System (ADS)

    Egusa, Shigenori; Iwasawa, Naozumi

    1998-08-01

    Piezoelectric paints have a potential to change a conventional structural material into an intelligent material system with health-monitoring capabilities such as vibration sensing and damage detection. Such paints were prepared using lead zirconate titanate (PZT) ceramic powder as a pigment and epoxy resin as a binder. The obtained paints were coated on aluminum test specimens, and were cured at room temperature or at 150 0964-1726/7/4/002/img5, thus forming the paint films having different thicknesses of 25-300 0964-1726/7/4/002/img6. These films were then poled at room temperature, and were evaluated with regard to the sensitivities as vibration and acoustic emission sensors in the frequency ranges of 0-250 Hz and 0-1.0 MHz, respectively. This paper mainly describes the effects of the film thickness and the cure temperature on the poling behavior of the PZT/epoxy paint film. This paper describes also the application of the paint film as a vibration modal sensor integrated into a structural material.

  7. Clinical use of anti-TNF therapy and increased risk of infections

    PubMed Central

    Ali, Tauseef; Kaitha, Sindhu; Mahmood, Sultan; Ftesi, Abdul; Stone, Jordan; Bronze, Michael S

    2013-01-01

    Biologics such as antitumor necrosis factor (anti-TNF) drugs have emerged as important agents in the treatment of many chronic inflammatory diseases, especially in cases refractory to conventional treatment modalities. However, opportunistic infections have become a major safety concern in patients on anti-TNF therapy, and physicians who utilize these agents must understand the increased risks of infection. A literature review of the published data on the risk of bacterial, viral, fungal, and parasitic infections associated with anti-TNF therapy was performed and the clinical presentation, diagnostic tests, management, and prevention of opportunistic infections in patients receiving anti-TNF therapy were reviewed. Awareness of the therapeutic potential and associated adverse events is necessary for maximizing therapeutic benefits while minimizing adverse effects from anti-TNF treatments. Patients should be adequately vaccinated when possible and closely monitored for early signs of infection. When serious infections occur, withdrawal of anti-TNF therapy may be necessary until the infection has been identified and properly treated. PMID:23569399

  8. Effect of Graphite Concentration on Shear-Wave Speed in Gelatin-Based Tissue-Mimicking Phantoms

    PubMed Central

    Anderson, Pamela G.; Rouze, Ned C.; Palmeri, Mark L.

    2011-01-01

    Elasticity-based imaging modalities are becoming popular diagnostic tools in clinical practice. Gelatin-based, tissue mimicking phantoms that contain graphite as the acoustic scattering material are commonly used in testing and validating elasticity-imaging methods to quantify tissue stiffness. The gelatin bloom strength and concentration are used to control phantom stiffness. While it is known that graphite concentration can be modulated to control acoustic attenuation, the impact of graphite concentrationon phantom elasticity has not been characterized in these gelatin phantoms. This work investigates the impact of graphite concentration on phantom shear stiffness as characterized by shear-wave speed measurements using impulsive acoustic-radiation-force excitations. Phantom shear-wave speed increased by 0.83 (m/s)/(dB/(cm MHz)) when increasing the attenuation coefficient slope of the phantom material through increasing graphite concentration. Therefore, gelatin-phantom stiffness can be affected by the conventional ways that attenuation is modulated through graphite concentration in these phantoms. PMID:21710828

  9. Coupled auralization and virtual video for immersive multimedia displays

    NASA Astrophysics Data System (ADS)

    Henderson, Paul D.; Torres, Rendell R.; Shimizu, Yasushi; Radke, Richard; Lonsway, Brian

    2003-04-01

    The implementation of maximally-immersive interactive multimedia in exhibit spaces requires not only the presentation of realistic visual imagery but also the creation of a perceptually accurate aural experience. While conventional implementations treat audio and video problems as essentially independent, this research seeks to couple the visual sensory information with dynamic auralization in order to enhance perceptual accuracy. An implemented system has been developed for integrating accurate auralizations with virtual video techniques for both interactive presentation and multi-way communication. The current system utilizes a multi-channel loudspeaker array and real-time signal processing techniques for synthesizing the direct sound, early reflections, and reverberant field excited by a moving sound source whose path may be interactively defined in real-time or derived from coupled video tracking data. In this implementation, any virtual acoustic environment may be synthesized and presented in a perceptually-accurate fashion to many participants over a large listening and viewing area. Subject tests support the hypothesis that the cross-modal coupling of aural and visual displays significantly affects perceptual localization accuracy.

  10. Statistical correlation of structural mode shapes from test measurements and NASTRAN analytical values

    NASA Technical Reports Server (NTRS)

    Purves, L.; Strang, R. F.; Dube, M. P.; Alea, P.; Ferragut, N.; Hershfeld, D.

    1983-01-01

    The software and procedures of a system of programs used to generate a report of the statistical correlation between NASTRAN modal analysis results and physical tests results from modal surveys are described. Topics discussed include: a mathematical description of statistical correlation, a user's guide for generating a statistical correlation report, a programmer's guide describing the organization and functions of individual programs leading to a statistical correlation report, and a set of examples including complete listings of programs, and input and output data.

  11. RF Modal Quantity Gaging

    NASA Technical Reports Server (NTRS)

    Vanleuven, K.

    1989-01-01

    The primary objective is to provide a concept of a radio frequency (RF) modal resonance technique which is being investigated as a method for gaging the quantities of subcritical cryogenic propellants in metallic tanks. Of special interest are the potential applications of the technique to microgravity propellant gaging situations. The results of concept testing using cryogenic oxygen, hydrogen, and nitrogen, as well as paraffin simulations of microgravity fluid orientations, are reported. These test results were positive and showed that the gaging concept was viable.

  12. Fluids and Combustion Facility: Fluids Integrated Rack Modal Model Correlation

    NASA Technical Reports Server (NTRS)

    McNelis, Mark E.; Suarez, Vicente J.; Sullivan, Timothy L.; Otten, Kim D.; Akers, James C.

    2005-01-01

    The Fluids Integrated Rack (FIR) is one of two racks in the Fluids and Combustion Facility on the International Space Station. The FIR is dedicated to the scientific investigation of space system fluids management supporting NASA s Exploration of Space Initiative. The FIR hardware was modal tested and FIR finite element model updated to satisfy the International Space Station model correlation criteria. The final cross-orthogonality results between the correlated model and test mode shapes was greater than 90 percent for all primary target modes.

  13. Extensor tendinopathy of the elbow assessed with sonoelastography: histologic correlation.

    PubMed

    Klauser, Andrea S; Pamminger, Mathias; Halpern, Ethan J; Abd Ellah, Mohamed M H; Moriggl, Bernhard; Taljanovic, Mihra S; Deml, Christian; Sztankay, Judit; Klima, Guenther; Jaschke, Werner R

    2017-08-01

    To compare agreement between conventional B-mode ultrasound (US) and compression sonoelastography (SEL) of the common extensor tendons of the elbow with histological evaluation. Twenty-six common extensor tendons were evaluated in 17 cadavers (11 females, median age 85 years and 6 males, median age 80 years). B-mode US was graded into: Grade 1, homogeneous fibrillar pattern; grade 2, hypoechoic areas and/or calcifications <30%; and grade 3 > 30%. SEL was graded into: Grade 1 indicated blue (hardest) to green (hard); grade 2 yellow (soft); and grade 3 red (softest). B-mode US, SEL, and a combined grading score incorporating both were compared to histological findings in 76 biopsies. Histological alterations were detected in 55/76 biopsies. Both modalities showed similar results (sensitivity, specificity, and accuracy 84%, 81%, and 83% for B-mode US versus 85%, 86%, and 86% for SEL, respectively, P > 0.3). However, a combination of both resulted in significant improvement in sensitivity (96%, P < 0.02) without significant change in specificity (81%, P < 0.3), yielding an improved overall accuracy (92%). Combined imaging of the extensor tendons with both modalities is superior to either modality alone for predicting the presence of pathologic findings on histology. • Combination of B-mode US and SEL proved efficiency in diagnosing lateral epicondylitis. • Combination of B-mode US and SEL in lateral epicondylitis correlates to histology. • Combination of both modalities provides improved sensitivity without loss of specificity.

  14. Convolutional neural networks for the detection of diseased hearts using CT images and left atrium patches

    NASA Astrophysics Data System (ADS)

    Dormer, James D.; Halicek, Martin; Ma, Ling; Reilly, Carolyn M.; Schreibmann, Eduard; Fei, Baowei

    2018-02-01

    Cardiovascular disease is a leading cause of death in the United States. The identification of cardiac diseases on conventional three-dimensional (3D) CT can have many clinical applications. An automated method that can distinguish between healthy and diseased hearts could improve diagnostic speed and accuracy when the only modality available is conventional 3D CT. In this work, we proposed and implemented convolutional neural networks (CNNs) to identify diseased hears on CT images. Six patients with healthy hearts and six with previous cardiovascular disease events received chest CT. After the left atrium for each heart was segmented, 2D and 3D patches were created. A subset of the patches were then used to train separate convolutional neural networks using leave-one-out cross-validation of patient pairs. The results of the two neural networks were compared, with 3D patches producing the higher testing accuracy. The full list of 3D patches from the left atrium was then classified using the optimal 3D CNN model, and the receiver operating curves (ROCs) were produced. The final average area under the curve (AUC) from the ROC curves was 0.840 +/- 0.065 and the average accuracy was 78.9% +/- 5.9%. This demonstrates that the CNN-based method is capable of distinguishing healthy hearts from those with previous cardiovascular disease.

  15. MS-QI: A Modulation Spectrum-Based ECG Quality Index for Telehealth Applications.

    PubMed

    Tobon V, Diana P; Falk, Tiago H; Maier, Martin

    2016-08-01

    As telehealth applications emerge, the need for accurate and reliable biosignal quality indices has increased. One typical modality used in remote patient monitoring is the electrocardiogram (ECG), which is inherently susceptible to several different noise sources, including environmental (e.g., powerline interference), experimental (e.g., movement artifacts), and physiological (e.g., muscle and breathing artifacts). Accurate measurement of ECG quality can allow for automated decision support systems to make intelligent decisions about patient conditions. This is particularly true for in-home monitoring applications, where the patient is mobile and the ECG signal can be severely corrupted by movement artifacts. In this paper, we propose an innovative ECG quality index based on the so-called modulation spectral signal representation. The representation quantifies the rate of change of ECG spectral components, which are shown to be different from the rate of change of typical ECG noise sources. The proposed modulation spectral-based quality index, MS-QI, was tested on 1) synthetic ECG signals corrupted by varying levels of noise, 2) single-lead recorded data using the Hexoskin garment during three activity levels (sitting, walking, running), 3) 12-lead recorded data using conventional ECG machines (Computing in Cardiology 2011 dataset), and 4) two-lead ambulatory ECG recorded from arrhythmia patients (MIT-BIH Arrhythmia Database). Experimental results showed the proposed index outperforming two conventional benchmark quality measures, particularly in the scenarios involving recorded data in real-world environments.

  16. Experimental and operational modal analysis of a laboratory scale model of a tripod support structure.

    NASA Astrophysics Data System (ADS)

    Luczak, M. M.; Mucchi, E.; Telega, J.

    2016-09-01

    The goal of the research is to develop a vibration-based procedure for the identification of structural failures in a laboratory scale model of a tripod supporting structure of an offshore wind turbine. In particular, this paper presents an experimental campaign on the scale model tested in two stages. Stage one encompassed the model tripod structure tested in air. The second stage was done in water. The tripod model structure allows to investigate the propagation of a circumferential representative crack of a cylindrical upper brace. The in-water test configuration included the tower with three bladed rotor. The response of the structure to the different waves loads were measured with accelerometers. Experimental and operational modal analysis was applied to identify the dynamic properties of the investigated scale model for intact and damaged state with different excitations and wave patterns. A comprehensive test matrix allows to assess the differences in estimated modal parameters due to damage or as potentially introduced by nonlinear structural response. The presented technique proves to be effective for detecting and assessing the presence of representative cracks.

  17. Rotorcraft Blade Mode Damping Identification from Random Responses Using a Recursive Maximum Likelihood Algorithm

    NASA Technical Reports Server (NTRS)

    Molusis, J. A.

    1982-01-01

    An on line technique is presented for the identification of rotor blade modal damping and frequency from rotorcraft random response test data. The identification technique is based upon a recursive maximum likelihood (RML) algorithm, which is demonstrated to have excellent convergence characteristics in the presence of random measurement noise and random excitation. The RML technique requires virtually no user interaction, provides accurate confidence bands on the parameter estimates, and can be used for continuous monitoring of modal damping during wind tunnel or flight testing. Results are presented from simulation random response data which quantify the identified parameter convergence behavior for various levels of random excitation. The data length required for acceptable parameter accuracy is shown to depend upon the amplitude of random response and the modal damping level. Random response amplitudes of 1.25 degrees to .05 degrees are investigated. The RML technique is applied to hingeless rotor test data. The inplane lag regressing mode is identified at different rotor speeds. The identification from the test data is compared with the simulation results and with other available estimates of frequency and damping.

  18. Rigid body mode identification of the PAH-2 helicopter using the eigensystem realization algorithm

    NASA Technical Reports Server (NTRS)

    Schenk, Axel; Pappa, Richard S.

    1992-01-01

    The rigid body modes of the PAH-2 'Tiger' helicopter were identified using the Eigensystem Realization Algorithm (ERA). This work complements ground vibration tests performed using DLR's traditional phase resonance technique and the ISSPA (Identification of Structural System Parameters) method. Rigid body modal parameters are important for ground resonance prediction. Time-domain data for ERA were obtained by inverse Fourier transformation of frequency response functions measured with stepped-sine excitation. Mode purity (based on the Phase Resonance Criterion) was generally equal to or greater than corresponding results obtained in the ground vibration tests. All identified natural frequencies and mode shapes correlate well with corresponding ground vibration test results. The modal identification approach discussed in this report has become increasingly attractive in recent years due to the steadily declining cost and increased performance of scientific computers. As illustrated in this application, modern time-domain methods can be successfully applied to data acquired using DLR's existing test equipment. Some suggestions are made for future applications of time domain modal identification in this manner.

  19. Lowering the Radiation Dose in Dental Offices.

    PubMed

    Radan, Elham

    2017-04-01

    While the use of dental imaging continues to evolve into more advanced modalities such as 3-D cone beam computed tomography, in addition to conventional 2-D imaging (intraoral, panoramic and cephalometric), the public concern for radiation safety is also increasing. This article is a guide for how to reduce patients’ exposure to the minimum with proper selection criteria (as needed only if it benefits the patient) and knowledge of effective doses, exposure parameters and proper collimation.

  20. 207-nm UV Light-A Promising Tool for Safe Low-Cost Reduction of Surgical Site Infections. II: In-Vivo Safety Studies.

    PubMed

    Buonanno, Manuela; Stanislauskas, Milda; Ponnaiya, Brian; Bigelow, Alan W; Randers-Pehrson, Gerhard; Xu, Yanping; Shuryak, Igor; Smilenov, Lubomir; Owens, David M; Brenner, David J

    2016-01-01

    UVC light generated by conventional germicidal lamps is a well-established anti-microbial modality, effective against both bacteria and viruses. However, it is a human health hazard, being both carcinogenic and cataractogenic. Earlier studies showed that single-wavelength far-UVC light (207 nm) generated by excimer lamps kills bacteria without apparent harm to human skin tissue in vitro. The biophysical explanation is that, due to its extremely short range in biological material, 207 nm UV light cannot penetrate the human stratum corneum (the outer dead-cell skin layer, thickness 5-20 μm) nor even the cytoplasm of individual human cells. By contrast, 207 nm UV light can penetrate bacteria and viruses because these cells are physically much smaller. To test the biophysically-based hypothesis that 207 nm UV light is not cytotoxic to exposed mammalian skin in vivo. Hairless mice were exposed to a bactericidal UV fluence of 157 mJ/cm2 delivered by a filtered Kr-Br excimer lamp producing monoenergetic 207-nm UV light, or delivered by a conventional 254-nm UV germicidal lamp. Sham irradiations constituted the negative control. Eight relevant cellular and molecular damage endpoints including epidermal hyperplasia, pre-mutagenic UV-associated DNA lesions, skin inflammation, and normal cell proliferation and differentiation were evaluated in mice dorsal skin harvested 48 h after UV exposure. While conventional germicidal UV (254 nm) exposure produced significant effects for all the studied skin damage endpoints, the same fluence of 207 nm UV light produced results that were not statistically distinguishable from the zero exposure controls. As predicted by biophysical considerations and in agreement with earlier in vitro studies, 207-nm light does not appear to be significantly cytotoxic to mouse skin. These results suggest that excimer-based far-UVC light could potentially be used for its anti-microbial properties, but without the associated hazards to skin of conventional germicidal UV lamps.

  1. 207-nm UV Light—A Promising Tool for Safe Low-Cost Reduction of Surgical Site Infections. II: In-Vivo Safety Studies

    PubMed Central

    Buonanno, Manuela; Stanislauskas, Milda; Ponnaiya, Brian; Bigelow, Alan W.; Randers-Pehrson, Gerhard; Xu, Yanping; Shuryak, Igor; Smilenov, Lubomir; Owens, David M.; Brenner, David J.

    2016-01-01

    Background UVC light generated by conventional germicidal lamps is a well-established anti-microbial modality, effective against both bacteria and viruses. However, it is a human health hazard, being both carcinogenic and cataractogenic. Earlier studies showed that single-wavelength far-UVC light (207 nm) generated by excimer lamps kills bacteria without apparent harm to human skin tissue in vitro. The biophysical explanation is that, due to its extremely short range in biological material, 207 nm UV light cannot penetrate the human stratum corneum (the outer dead-cell skin layer, thickness 5–20 μm) nor even the cytoplasm of individual human cells. By contrast, 207 nm UV light can penetrate bacteria and viruses because these cells are physically much smaller. Aims To test the biophysically-based hypothesis that 207 nm UV light is not cytotoxic to exposed mammalian skin in vivo. Methods Hairless mice were exposed to a bactericidal UV fluence of 157 mJ/cm2 delivered by a filtered Kr-Br excimer lamp producing monoenergetic 207-nm UV light, or delivered by a conventional 254-nm UV germicidal lamp. Sham irradiations constituted the negative control. Eight relevant cellular and molecular damage endpoints including epidermal hyperplasia, pre-mutagenic UV-associated DNA lesions, skin inflammation, and normal cell proliferation and differentiation were evaluated in mice dorsal skin harvested 48 h after UV exposure. Results While conventional germicidal UV (254 nm) exposure produced significant effects for all the studied skin damage endpoints, the same fluence of 207 nm UV light produced results that were not statistically distinguishable from the zero exposure controls. Conclusions As predicted by biophysical considerations and in agreement with earlier in vitro studies, 207-nm light does not appear to be significantly cytotoxic to mouse skin. These results suggest that excimer-based far-UVC light could potentially be used for its anti-microbial properties, but without the associated hazards to skin of conventional germicidal UV lamps. PMID:27275949

  2. Comparison of conventional color fundus photography and multicolor imaging in choroidal or retinal lesions.

    PubMed

    Muftuoglu, Ilkay Kilic; Gaber, Raouf; Bartsch, Dirk-Uwe; Meshi, Amit; Goldbaum, Michael; Freeman, William R

    2018-04-01

    Our purpose was to compare the characteristics of the retinal and choroidal lesions including choroidal nevus, choroidal melanoma and congenital hypertrophy of the retina pigment epithelium using conventional color fundus photography (CFP) and multicolor imaging (MCI). The paired images of patients with retinal or choroidal lesions were assessed for the visibility of lesion's border, halo and drusen using a grading scale (0-2). The area of the lesion was measured on both imaging modalities. The same grading was also done on the individual color channels of MCI for a further evaluation. Thirty-three eyes of 33 patients were included. There were no significant differences in the mean border, drusen and halo visibility scores between the two imaging modalities (p = 0.12, p = 0.70, p = 0.35). However, the mean area of the lesion was significantly smaller on MCI than that on CFP (14.9±3.3 versus 18.7±3.4 mm 2 , p = 0.01). The appearance of choroidal and/ or retinal lesions on MCI may be different than that on CFP. Though MCI can provide similar information with CFP for the features of retinal and/ or choroidal lesions including border, halo and drusen; the infrared light reflection on MCI underestimates the extent of the choroidal lesion by 33%.

  3. Assisted reproduction and risk of preterm birth in singletons by infertility diagnoses and treatment modalities: a population-based study.

    PubMed

    Dunietz, Galit Levi; Holzman, Claudia; Zhang, Yujia; Li, Chenxi; Todem, David; Boulet, Sheree L; McKane, Patricia; Kissin, Dmitry M; Copeland, Glenn; Bernson, Dana; Diamond, Michael P

    2017-11-01

    The purpose of this study is to examine the spectrum of infertility diagnoses and assisted reproductive technology (ART) treatments in relation to risk of preterm birth (PTB) in singletons. Population-based assisted reproductive technology surveillance data for 2000-2010 were linked with birth certificates from three states: Florida, Massachusetts, and Michigan, resulting in a sample of 4,370,361 non-ART and 28,430 ART-related singletons. Logistic regression models with robust variance estimators were used to compare PTB risk among singletons conceived with and without ART, the former grouped by parental infertility diagnoses and treatment modalities. Demographic and pregnancy factors were included in adjusted analyses. ART was associated with increased PTB risk across all infertility diagnosis groups and treatment types: for conventional ART, adjusted relative risks ranged from 1.4 (95% CI 1.0, 1.9) for male infertility to 2.4 (95% CI 1.8, 3.3) for tubal ligation. Adding intra-cytoplasmic sperm injection and/or assisted hatching to conventional ART treatment did not alter associated PTB risks. Singletons conceived by mothers without infertility diagnosis and with donor semen had an increased PTB risk relative to non-ART singletons. PTB risk among ART singletons is increased within each treatment type and all underlying infertility diagnosis, including male infertility. Preterm birth in ART singletons may be attributed to parental infertility, ART treatments, or their combination.

  4. Role of four-dimensional echocardiography with high-definition flow imaging and spatiotemporal image correlation in detecting fetal pulmonary veins.

    PubMed

    Sun, Xue; Zhang, Ying; Fan, Miao; Wang, Yu; Wang, Meilian; Siddiqui, Faiza Amber; Sun, Wei; Sun, Feifei; Zhang, Dongyu; Lei, Wenjia; Hu, Guyue

    2017-06-01

    Prenatal diagnosis of fetal total anomalous pulmonary vein connection (TAPVC) remains challenging for most screening sonographers. The purpose of this study was to evaluate the use of four-dimensional echocardiography with high-definition flow imaging and spatiotemporal image correlation (4D-HDFI) in identifying pulmonary veins in normal and TAPVC fetuses. We retrospectively reviewed and performed 4D-HDFI in 204 normal and 12 fetuses with confirmed diagnosis of TAPVC. Cardiac volumes were available for postanalysis to obtain 4D-rendered images of the pulmonary veins. For the normal fetuses, two other traditional modalities including color Doppler and HDFI were used to detect the number of pulmonary veins and comparisons were made between each of these traditional methods and 4D-HDFI. For conventional echocardiography, HDFI modality was superior to color Doppler in detecting more pulmonary veins in normal fetuses throughout the gestational period. 4D-HDFI was the best method during the second trimester of pregnancy in identifying normal fetal pulmonary veins. 4D-HDFI images vividly depicted the figure, course, and drainage of pulmonary veins in both normal and TAPVC fetuses. HDFI and the advanced 4D-HDFI technique could facilitate identification of the anatomical features of pulmonary veins in both normal and TAPVC fetuses; 4D-HDFI therefore provides additional and more precise information than conventional echocardiography techniques. © 2017, Wiley Periodicals, Inc.

  5. Three-Dimensional Virtual Sonographic Cystoscopy for Detection of Ureterocele in Duplicated Collecting Systems in Children.

    PubMed

    Nabavizadeh, Behnam; Mozafarpour, Sarah; Hosseini Sharifi, Seyed Hossein; Nabavizadeh, Reza; Abbasioun, Reza; Kajbafzadeh, Abdol-Mohammad

    2018-03-01

    Ureterocele is a sac-like dilatation of terminal ureter. Precise anatomic delineation is of utmost importance to proceed with the surgical plan, particularly in the ectopic subtype. However, the level of ureterocele extension is not always elucidated by the existing imaging modalities and even by conventional cystoscopy, which is considered as the gold standard for evaluation of ureterocele. This study aims to evaluate the accuracy of three-dimensional virtual sonographic cystoscopy (VSC) in the characterization of ureterocele in duplex collecting systems. Sixteen children with a mean age of 5.1 (standard deviation 1.96) years with transabdominal ultrasonography-proven duplex system and ureterocele were included. They underwent VSC by a single pediatric radiologist. All of them subsequently had conventional cystoscopy, and the results were compared in terms of ureterocele features including anatomy, number, size, location, and extension. Three-dimensional VSC was well tolerated in all cases without any complication. Image quality was suboptimal in 2 of 16 patients. Out of the remaining 14 cases, VSC had a high accuracy in characterization of the ureterocele features (93%). Only the extension of one ureterocele was not precisely detected by VSC. The results of this study suggest three-dimensional sonography as a promising noninvasive diagnostic modality in the evaluation of ectopic ureterocele in children. © 2017 by the American Institute of Ultrasound in Medicine.

  6. Evaluation of photoshop based image analysis in cytologic diagnosis of pleural fluid in comparison with conventional modalities.

    PubMed

    Jafarian, Amir Hossein; Tasbandi, Aida; Mohamadian Roshan, Nema

    2018-04-19

    The aim of this study is to investigate and compare the results of digital image analysis in pleural effusion cytology samples with conventional modalities. In this cross-sectional study, 53 pleural fluid cytology smears from Qaem hospital pathology department, located in Mashhad, Iran were investigated. Prior to digital analysis, all specimens were evaluated by two pathologists and categorized into three groups as: benign, suspicious, and malignant. Using an Olympus microscope and Olympus DP3 digital camera, digital images from cytology slides were captured. Appropriate images (n = 130) were separately imported to Adobe Photoshop CS5 and parameters including area and perimeter, circularity, Gray Value mean, integrated density, and nucleus to cytoplasm area ratio were analyzed. Gray Value mean, nucleus to cytoplasm area ratio, and circularity showed the best sensitivity and specificity rates as well as significant differences between all groups. Also, nucleus area and perimeter showed a significant relation between suspicious and malignant groups with benign group. Whereas, there was no such difference between suspicious and malignant groups. We concluded that digital image analysis is welcomed in the field of research on pleural fluid smears as it can provide quantitative data to apply various comparisons and reduce interobserver variation which could assist pathologists to achieve a more accurate diagnosis. © 2018 Wiley Periodicals, Inc.

  7. Conventional digital subtractional vs non-invasive MR angiography in the assessment of brain arteriovenous malformation.

    PubMed

    Cuong, Nguyen Ngoc; Luu, Vu Dang; Tuan, Tran Anh; Linh, Le Tuan; Hung, Kieu Dinh; Ngoc, Vo Truong Nhu; Sharma, Kulbhushan; Pham, Van Huy; Chu, Dinh-Toi

    2018-06-01

    Digital subtractional angiography (DSA) is the standard method for diagnosis, assessment and management of arteriovenous malformation in the brain. Conventional DSA (cDSA) is an invasive imaging modality that is often indicated before interventional treatments (embolization, open surgery, gamma knife). Here, we aimed to compare this technique with a non-invasive MR angiography (MRI DSA) for brain arteriovenous malformation (bAVM). Fourteen patients with ruptured brain AVM underwent embolization treatment pre-operation. Imaging was performed for all patients using MRI (1.5 T). After injecting contrast Gadolinium, dynamic MRI was performed with 40 phases, each phase of a duration of 1.2 s and having 70 images. The MRI results were independently assessed by experienced radiologist blinded to the cDSA. The AVM nidus was depicted in all patients using cDSA and MRI DSA; there was an excellent correlation between these techniques in terms of the maximum diameter and Spetzler Martin grading. Of the fourteen patients, the drainage vein was depicted in 13 by both cDSA and MRI DSA showing excellent correlation between the techniques used. MRI DSA is a non-invasive imaging modality that can give the images in dynamic view. It can be considered as an adjunctive method with cDSA to plan the strategy treatment for bAVM. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Optical diffraction tomography with fully and partially coherent illumination in high numerical aperture label-free microscopy [Invited].

    PubMed

    Soto, Juan M; Rodrigo, José A; Alieva, Tatiana

    2018-01-01

    Quantitative label-free imaging is an important tool for the study of living microorganisms that, during the last decade, has attracted wide attention from the optical community. Optical diffraction tomography (ODT) is probably the most relevant technique for quantitative label-free 3D imaging applied in wide-field microscopy in the visible range. The ODT is usually performed using spatially coherent light illumination and specially designed holographic microscopes. Nevertheless, the ODT is also compatible with partially coherent illumination and can be realized in conventional wide-field microscopes by applying refocusing techniques, as it has been recently demonstrated. Here, we compare these two ODT modalities, underlining their pros and cons and discussing the optical setups for their implementation. In particular, we pay special attention to a system that is compatible with a conventional wide-field microscope that can be used for both ODT modalities. It consists of two easily attachable modules: the first for sample illumination engineering based on digital light processing technology; the other for focus scanning by using an electrically driven tunable lens. This hardware allows for a programmable selection of the wavelength and the illumination design, and provides fast data acquisition as well. Its performance is experimentally demonstrated in the case of ODT with partially coherent illumination providing speckle-free 3D quantitative imaging.

  9. High-resolution 3D volumetry versus conventional measuring techniques for the assessment of experimental lymphedema in the mouse hindlimb

    PubMed Central

    Frueh, Florian S.; Körbel, Christina; Gassert, Laura; Müller, Andreas; Gousopoulos, Epameinondas; Lindenblatt, Nicole; Giovanoli, Pietro; Laschke, Matthias W.; Menger, Michael D.

    2016-01-01

    Secondary lymphedema is a common complication of cancer treatment characterized by chronic limb swelling with interstitial inflammation. The rodent hindlimb is a widely used model for the evaluation of novel lymphedema treatments. However, the assessment of limb volume in small animals is challenging. Recently, high-resolution three-dimensional (3D) imaging modalities have been introduced for rodent limb volumetry. In the present study we evaluated the validity of microcomputed tomography (μCT), magnetic resonance imaging (MRI) and ultrasound in comparison to conventional measuring techniques. For this purpose, acute lymphedema was induced in the mouse hindlimb by a modified popliteal lymphadenectomy. The 4-week course of this type of lymphedema was first assessed in 6 animals. In additional 12 animals, limb volumes were analyzed by μCT, 9.4 T MRI and 30 MHz ultrasound as well as by planimetry, circumferential length and paw thickness measurements. Interobserver correlation was high for all modalities, in particular for μCT analysis (r = 0.975, p < 0.001). Importantly, caliper-measured paw thickness correlated well with μCT (r = 0.861), MRI (r = 0.821) and ultrasound (r = 0.800). Because the assessment of paw thickness represents a time- and cost-effective approach, it may be ideally suited for the quantification of rodent hindlimb lymphedema. PMID:27698469

  10. The effectiveness of multi modal representation text books to improve student's scientific literacy of senior high school students

    NASA Astrophysics Data System (ADS)

    Zakiya, Hanifah; Sinaga, Parlindungan; Hamidah, Ida

    2017-05-01

    The results of field studies showed the ability of science literacy of students was still low. One root of the problem lies in the books used in learning is not oriented toward science literacy component. This study focused on the effectiveness of the use of textbook-oriented provisioning capability science literacy by using multi modal representation. The text books development method used Design Representational Approach Learning to Write (DRALW). Textbook design which was applied to the topic of "Kinetic Theory of Gases" is implemented in XI grade students of high school learning. Effectiveness is determined by consideration of the effect and the normalized percentage gain value, while the hypothesis was tested using Independent T-test. The results showed that the textbooks which were developed using multi-mode representation science can improve the literacy skills of students. Based on the size of the effect size textbooks developed with representation multi modal was found effective in improving students' science literacy skills. The improvement was occurred in all the competence and knowledge of scientific literacy. The hypothesis testing showed that there was a significant difference on the ability of science literacy between class that uses textbooks with multi modal representation and the class that uses the regular textbook used in schools.

  11. Modal characterization of the ASCIE segmented optics testbed: New algorithms and experimental results

    NASA Technical Reports Server (NTRS)

    Carrier, Alain C.; Aubrun, Jean-Noel

    1993-01-01

    New frequency response measurement procedures, on-line modal tuning techniques, and off-line modal identification algorithms are developed and applied to the modal identification of the Advanced Structures/Controls Integrated Experiment (ASCIE), a generic segmented optics telescope test-bed representative of future complex space structures. The frequency response measurement procedure uses all the actuators simultaneously to excite the structure and all the sensors to measure the structural response so that all the transfer functions are measured simultaneously. Structural responses to sinusoidal excitations are measured and analyzed to calculate spectral responses. The spectral responses in turn are analyzed as the spectral data become available and, which is new, the results are used to maintain high quality measurements. Data acquisition, processing, and checking procedures are fully automated. As the acquisition of the frequency response progresses, an on-line algorithm keeps track of the actuator force distribution that maximizes the structural response to automatically tune to a structural mode when approaching a resonant frequency. This tuning is insensitive to delays, ill-conditioning, and nonproportional damping. Experimental results show that is useful for modal surveys even in high modal density regions. For thorough modeling, a constructive procedure is proposed to identify the dynamics of a complex system from its frequency response with the minimization of a least-squares cost function as a desirable objective. This procedure relies on off-line modal separation algorithms to extract modal information and on least-squares parameter subset optimization to combine the modal results and globally fit the modal parameters to the measured data. The modal separation algorithms resolved modal density of 5 modes/Hz in the ASCIE experiment. They promise to be useful in many challenging applications.

  12. Ultra-Wide Field Imaging in Paradoxical Worsening of Tubercular Multifocal Serpiginoid Choroiditis after the Initiation of Anti-Tubercular Therapy.

    PubMed

    Aggarwal, Kanika; Agarwal, Aniruddha; Deokar, Ankit; Singh, Ramandeep; Bansal, Reema; Sharma, Aman; Sharma, Kusum; Dogra, Mangat R; Gupta, Vishali

    2017-10-11

    To evaluate role of ultra-wide field (UWF) versus conventional imaging in the follow-up and paradoxical worsening (PW) of tubercular (TB) multifocal serpiginoid choroiditis (MSC). Prospective observational study of patients with TB MSC undergoing UWF imaging, autofluorescence and fluorescein angiography was performed. A circle simulating central 75° field representing conventional imaging was drawn on UWF images. The information yielded by the two modalities, progression of choroiditis lesions and PW was compared. 44 eyes (29 patients, mean age: 30.7 ± 9 years; 23 males) were included. UWF imaging showed additional lesions in 39/44 eyes (88.6%). Overall, 16/44 eyes (36.4%) showed PW; 3/16 eyes (18.7%) showed only peripheral PW, while 10/16 eyes showed both central and peripheral PW. Management was altered in 11 patients (37.93%) based on UWF imaging. UWF is more useful than conventional imaging in identifying additional choroiditis lesions, PW and altering the course of therapy in TB MSC.

  13. Effect of various tooth whitening modalities on microhardness, surface roughness and surface morphology of the enamel.

    PubMed

    Kwon, So Ran; Kurti, Steven R; Oyoyo, Udochukwu; Li, Yiming

    2015-09-01

    The purpose of this study was to evaluate the effect of four whitening modalities on surface enamel as assessed with microhardness tester, profilometer, and scanning electron microscopy (SEM). Whitening was performed according to manufacturer's directions for over-the-counter (OTC), dentist dispensed for home use (HW) and in-office (OW) whitening. Do-it-yourself (DIY) whitening consisted of a strawberry and baking soda mix. Additionally, negative and positive controls were used. A total of 120 enamel specimens were used for microhardness testing at baseline and post-whitening. Following microhardness testing specimens were prepared for SEM observations. A total of 120 enamel specimens were used for surface roughness testing at baseline and post-whitening (n = 20 per group). Rank-based Analysis of Covariance was performed to compare microhardness and surface roughness changes. Tests of hypotheses were two-sided with α = 0.05. There was a significant difference in Knoop hardness changes (ΔKHN) among the groups (Kruskal-Wallis test, p < 0.0001). Significant hardness reduction was observed in the positive control and DIY group (p < 0.0001). Mean surface roughness changes (ΔRa) were significantly different among the groups (Kruskal-Wallis test, p < 0.0001). Surface roughness increased in the OTC group (p = 0.03) and in the positive control (p < 0.0001). The four whitening modalities-DIY, OTC, HW and OW induced minimal surface morphology changes when observed with SEM. It can be concluded that none of the four whitening modalities adversely affected enamel surface morphology. However, caution should be advised when using a DIY regimen as it may affect enamel microhardness and an OTC product as it has the potential to increase surface roughness.

  14. Effects of whole-body cryotherapy vs. far-infrared vs. passive modalities on recovery from exercise-induced muscle damage in highly-trained runners.

    PubMed

    Hausswirth, Christophe; Louis, Julien; Bieuzen, François; Pournot, Hervé; Fournier, Jean; Filliard, Jean-Robert; Brisswalter, Jeanick

    2011-01-01

    Enhanced recovery following physical activity and exercise-induced muscle damage (EIMD) has become a priority for athletes. Consequently, a number of post-exercise recovery strategies are used, often without scientific evidence of their benefits. Within this framework, the purpose of this study was to test the efficacy of whole body cryotherapy (WBC), far infrared (FIR) or passive (PAS) modalities in hastening muscular recovery within the 48 hours after a simulated trail running race. In 3 non-adjoining weeks, 9 well-trained runners performed 3 repetitions of a simulated trail run on a motorized treadmill, designed to induce muscle damage. Immediately (post), post 24 h, and post 48 h after exercise, all participants tested three different recovery modalities (WBC, FIR, PAS) in a random order over the three separate weeks. Markers of muscle damage (maximal isometric muscle strength, plasma creatine kinase [CK] activity and perceived sensations [i.e. pain, tiredness, well-being]) were recorded before, immediately after (post), post 1 h, post 24 h, and post 48 h after exercise. In all testing sessions, the simulated 48 min trail run induced a similar, significant amount of muscle damage. Maximal muscle strength and perceived sensations were recovered after the first WBC session (post 1 h), while recovery took 24 h with FIR, and was not attained through the PAS recovery modality. No differences in plasma CK activity were recorded between conditions. Three WBC sessions performed within the 48 hours after a damaging running exercise accelerate recovery from EIMD to a greater extent than FIR or PAS modalities.

  15. Effects of Whole-Body Cryotherapy vs. Far-Infrared vs. Passive Modalities on Recovery from Exercise-Induced Muscle Damage in Highly-Trained Runners

    PubMed Central

    Hausswirth, Christophe; Louis, Julien; Bieuzen, François; Pournot, Hervé; Fournier, Jean; Filliard, Jean-Robert; Brisswalter, Jeanick

    2011-01-01

    Enhanced recovery following physical activity and exercise-induced muscle damage (EIMD) has become a priority for athletes. Consequently, a number of post-exercise recovery strategies are used, often without scientific evidence of their benefits. Within this framework, the purpose of this study was to test the efficacy of whole body cryotherapy (WBC), far infrared (FIR) or passive (PAS) modalities in hastening muscular recovery within the 48 hours after a simulated trail running race. In 3 non-adjoining weeks, 9 well-trained runners performed 3 repetitions of a simulated trail run on a motorized treadmill, designed to induce muscle damage. Immediately (post), post 24 h, and post 48 h after exercise, all participants tested three different recovery modalities (WBC, FIR, PAS) in a random order over the three separate weeks. Markers of muscle damage (maximal isometric muscle strength, plasma creatine kinase [CK] activity and perceived sensations [i.e. pain, tiredness, well-being]) were recorded before, immediately after (post), post 1 h, post 24 h, and post 48 h after exercise. In all testing sessions, the simulated 48 min trail run induced a similar, significant amount of muscle damage. Maximal muscle strength and perceived sensations were recovered after the first WBC session (post 1 h), while recovery took 24 h with FIR, and was not attained through the PAS recovery modality. No differences in plasma CK activity were recorded between conditions. Three WBC sessions performed within the 48 hours after a damaging running exercise accelerate recovery from EIMD to a greater extent than FIR or PAS modalities. PMID:22163272

  16. Student learning style preferences in college-level biology courses: Implications for teaching and academic performance

    NASA Astrophysics Data System (ADS)

    Sitton, Jennifer Susan

    Education research has focused on defining and identifying student learning style preferences and how to incorporate this knowledge into teaching practices that are effective in engaging student interest and transmitting information. One objective was determining the learning style preferences of undergraduate students in Biology courses at New Mexico State University by using the online VARK Questionnaire and an investigator developed survey (Self Assessed Learning Style Survey, LSS). Categories include visual, aural, read-write, kinesthetic, and multimodal. The courses differed in VARK single modal learning preferences (p = 0.035) but not in the proportions of the number of modes students preferred (p = 0.18). As elsewhere, the majority of students were multimodal. There were similarities and differences between LSS and VARK results and between students planning on attending medical school and those not. Preferences and modalities tended not to match as expected for ratings of helpfulness of images and text. To detect relationships between VARK preferred learning style and academic performance, ANOVAs were performed using modality preferences and normalized learning gains from pre and post tests over material taught in the different modalities, as well as on end of semester laboratory and lecture grades. Overall, preference did not affect the performance for a given modality based activity, quiz, or final lecture or laboratory grades (p > 0.05). This suggests that a student's preference does not predict an improved performance when supplied with material in that modality. It is recommended that methods be developed to aid learning in a variety of modalities, rather than catering to individual learning styles. Another topic that is heavily debated in the field of education is the use of simulations or videos to replace or supplement dissections. These activities were compared using normalized learning gains from pre and post tests, as well as attitude surveys. Results indicate no differences in average student learning gain based on the activity types tested, although students do rate dissections higher in terms of interest and enthusiasm. Dissections also offer a different type of learning. Therefore, it is suggested that simulations and videos be used as supplements for dissections and not as replacements.

  17. Clinical Value of a One-Stop-Shop Low-Dose Lung Screening Combined with (18)F-FDG PET/CT for the Detection of Metastatic Lung Nodules from Colorectal Cancer.

    PubMed

    Han, Yeon-Hee; Lim, Seok Tae; Jeong, Hwan-Jeong; Sohn, Myung-Hee

    2016-06-01

    The aim of this study was to evaluate the clinical usefulness of additional low-dose high-resolution lung computed tomography (LD-HRCT) combined with (18)F-fluoro-2-deoxyglucose positron emission tomography with CT ((18)F-FDG PET/CT) compared with conventional lung setting image of (18)F-FDG PET/CT for the detection of metastatic lung nodules from colorectal cancer. From January 2011 to September 2011, 649 patients with colorectal cancer underwent additional LD-HRCT at maximum inspiration combined with (18)F-FDG PET/CT. Forty-five patients were finally diagnosed to have lung metastasis based on histopathologic study or clinical follow-up. Twenty-five of the 45 patients had ≤5 metastatic lung nodules and the other 20 patients had >5 metastatic nodules. One hundred and twenty nodules in the 25 patients with ≤5 nodules were evaluated by conventional lung setting image of (18)F-FDG PET/CT and by additional LD-HRCT respectively. Sensitivities, specificities, diagnostic accuracies, positive predictive values (PPVs), and negative predictive values (NPVs) of conventional lung setting image of (18)F-FDG PET/CT and additional LD-HRCT were calculated using standard formulae. The McNemar test and receiver-operating characteristic (ROC) analysis were performed. Of the 120 nodules in the 25 patients with ≤5 metastatic lung nodules, 66 nodules were diagnosed as metastatic. Eleven of the 66 nodules were confirmed histopathologically and the others were diagnosed by clinical follow-up. Conventional lung setting image of (18)F-FDG PET/CT detected 40 of the 66 nodules and additional LD-HRCT detected 55 nodules. All 15 nodules missed by conventional lung setting imaging but detected by additional LD-HRCT were <1 cm in size. The sensitivity, specificity, and diagnostic accuracy of the modalities were 60.6 %, 85.2 %, and 71.1 % for conventional lung setting image and 83.3 %, 88.9 %, and 85.8 % for additional LD-HRCT. By ROC analysis, the area under the ROC curve (AUC) of conventional lung setting image and additional LD-HRCT were 0.712 and 0.827 respectively. Additional LD-HRCT with maximum inspiration was superior to conventional lung setting image of (18)F-FDG PET/CT for the detection of metastatic lung nodules from colorectal cancer (P < 0.05).

  18. Nonlinear Dynamic Behavior in the Cassini Spacecraft Modal Survey

    NASA Technical Reports Server (NTRS)

    Carney, Kelly S.

    1997-01-01

    In October 1997, the 6-ton robotic spacecraft, Cassini, will lift off from Cape Canaveral atop a Titan IV B rocket, beginning a 7-year journey to Saturn. Upon completion of that voyage, Cassini will send the Huygens probe into the atmosphere of Saturn's largest moon, Titan. Cassini will then spend years studying Saturn's vast realm of rings, icy moons, and magnetic fields. The size and complexity of this endeavor mandates the involvement of many organizations. The Jet Propulsion Laboratory (JPL) manages the project for NASA and is responsible for the spacecraft design, development, and assembly. The NASA Lewis Research Center is the launch system integrator. As is typical for such a spacecraft, a test-verified finite element model is required for loads analysis. JPL had responsibility for the Cassini modal survey and the development of the spacecraft test-verified finite element model. Test verification is a complex and sometimes subjective process. Because of this, NASA Lewis independently verified and validated the Cassini spacecraft modal survey.

  19. Interidentity memory transfer in dissociative identity disorder.

    PubMed

    Kong, Lauren L; Allen, John J B; Glisky, Elizabeth L

    2008-08-01

    Controversy surrounding dissociative identity disorder (DID) has focused on conflicting findings regarding the validity and nature of interidentity amnesia, illustrating the need for objective methods of examining amnesia that can discriminate between explicit and implicit memory transfer. In the present study, the authors used a cross-modal manipulation designed to mitigate implicit memory effects. Explicit memory transfer between identities was examined in 7 DID participants and 34 matched control participants. After words were presented to one identity auditorily, the authors tested another identity for memory of those words in the visual modality using an exclusion paradigm. Despite self-reported interidentity amnesia, memory for experimental stimuli transferred between identities. DID patients showed no superior ability to compartmentalize information, as would be expected with interidentity amnesia. The cross-modal nature of the test makes it unlikely that memory transfer was implicit. These findings demonstrate that subjective reports of interidentity amnesia are not necessarily corroborated by objective tests of explicit memory transfer. Copyright (c) 2008 APA, all rights reserved.

  20. Lip-read me now, hear me better later: cross-modal transfer of talker-familiarity effects.

    PubMed

    Rosenblum, Lawrence D; Miller, Rachel M; Sanchez, Kauyumari

    2007-05-01

    There is evidence that for both auditory and visual speech perception, familiarity with the talker facilitates speech recognition. Explanations of these effects have concentrated on the retention of talker information specific to each of these modalities. It could be, however, that some amodal, talker-specific articulatory-style information facilitates speech perception in both modalities. If this is true, then experience with a talker in one modality should facilitate perception of speech from that talker in the other modality. In a test of this prediction, subjects were given about 1 hr of experience lipreading a talker and were then asked to recover speech in noise from either this same talker or a different talker. Results revealed that subjects who lip-read and heard speech from the same talker performed better on the speech-in-noise task than did subjects who lip-read from one talker and then heard speech from a different talker.

Top