Ma, Guoqing; Ye, Ting; Sun, Zhongren
2018-03-12
To compare the clinical efficacy differences between warming acupuncture and conventional acupuncture for diabetic peripheral neuropathy (DPN) with syndrome of yang deficiency and cold coagulation, obstruction of collaterals and blood stasis. A total of 64 patients were randomly divided into a warming acupuncture group and a conventional acupuncture group, 32 cases in each one. Based on basic treatment of blood glucose regulation, warming acupuncture was applied at Pishu (BL 20), Shenshu (BL 23), Guanyuanshu (BL 26), Zusanli (ST 36), Chongyang (ST 42), Quchi (LI 11) and Hegu (LI 4) in the warming acupuncture group, while acupuncture was applied at the identical acupoints in the conventional acupuncture group. Both the treatments were given once a day with an interval of one day every six days; totally the treatment was given for 4 weeks. The TCM symptom score, Toronto clinical scoring system (TCSS) and nerve conduction velocity (NCV) before and after treatment were compared in the two groups. After treatment, the TCM symptom scores in the two groups were significantly reduced (both P <0.01); the improvement of TCM symptom in the warming acupuncture group was superior to that in the conventional acupuncture group ( P <0.05). After treatment, the TCSS scores in the two groups were significantly reduced (both P <0.01); the TCSS score in the warming acupuncture group was significantly lower than that in the conventional acupuncture group ( P <0.05). After treatment, the NCV of motor nerve of tibial nerve and nervus peroneus communis, as well as sensory nerve of tibial nerve and sural nerve was improved in the warming acupuncture group (all P <0.05), while only the NCV of motor nerve and sensory nerve of tibial nerve was improved in the conventional acupuncture group (both P <0.05); there were no significant difference between the two groups (all P >0.05). Warming acupuncture and conventional acupuncture could both increase TCM symptom score, improve NCV in patients of DPN with syndrome of yang deficiency and cold coagulation, obstruction of collaterals and blood stasis; warming acupuncture has advantage in symptom improvement.
Development of a nerve conduction technique for the recurrent laryngeal nerve.
J Kim, Sang; G Lee, Dae; Kwon, Jeong-Yi
2014-12-01
To develop a reliable and safe laryngeal nerve conduction technique and to obtain consistent parameters as normal reference values. A prospective single-arm study. A nerve conduction test was performed on the contralateral normal side in 42 patients with unilateral vocal fold palsy. The recording was performed in the intact thyroarytenoid muscle using a monopolar needle. The electrical stimulation using a 37-mm monopolar needle was applied 3 cm below the lower margin of the cricoid cartilage, just lateral to the trachea and medial to the carotid artery, and its intensity was gradually increased until the amplitude of the electrical response reached the maximum level. The latency of the evoked muscle response was acquired at the first evoked waveform deflection from the baseline. The average latency of the recurrent laryngeal nerves was 1.98 ± 0.26 ms. The latencies showed normal distribution according to the quantile-quantile plot and Kolmogorov-Smirnov test (P = .098). There was no significant difference in latencies between the right and left recurrent laryngeal nerves. Anthropometric factors including height and weight did not show any correlation with the latencies. We developed a reliable and safe laryngeal nerve conduction technique and obtained normal reference values for the recurrent laryngeal nerve conduction study. This laryngeal nerve conduction study can be an additional tool for detecting recurrent laryngeal nerve injury if it is performed in combination with the conventional laryngeal electromyography. 4. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
Ghasemi-Mobarakeh, Laleh; Prabhakaran, Molamma P; Morshed, Mohammad; Nasr-Esfahani, Mohammad Hossein; Baharvand, Hossein; Kiani, Sahar; Al-Deyab, Salem S; Ramakrishna, Seeram
2011-04-01
Among the numerous attempts to integrate tissue engineering concepts into strategies to repair nearly all parts of the body, neuronal repair stands out. This is partially due to the complexity of the nervous anatomical system, its functioning and the inefficiency of conventional repair approaches, which are based on single components of either biomaterials or cells alone. Electrical stimulation has been shown to enhance the nerve regeneration process and this consequently makes the use of electrically conductive polymers very attractive for the construction of scaffolds for nerve tissue engineering. In this review, by taking into consideration the electrical properties of nerve cells and the effect of electrical stimulation on nerve cells, we discuss the most commonly utilized conductive polymers, polypyrrole (PPy) and polyaniline (PANI), along with their design and modifications, thus making them suitable scaffolds for nerve tissue engineering. Other electrospun, composite, conductive scaffolds, such as PANI/gelatin and PPy/poly(ε-caprolactone), with or without electrical stimulation, are also discussed. Different procedures of electrical stimulation which have been used in tissue engineering, with examples on their specific applications in tissue engineering, are also discussed. Copyright © 2011 John Wiley & Sons, Ltd.
New Theoretical Model of Nerve Conduction in Unmyelinated Nerves
Akaishi, Tetsuya
2017-01-01
Nerve conduction in unmyelinated fibers has long been described based on the equivalent circuit model and cable theory. However, without the change in ionic concentration gradient across the membrane, there would be no generation or propagation of the action potential. Based on this concept, we employ a new conductive model focusing on the distribution of voltage-gated sodium ion channels and Coulomb force between electrolytes. Based on this new model, the propagation of the nerve conduction was suggested to take place far before the generation of action potential at each channel. We theoretically showed that propagation of action potential, which is enabled by the increasing Coulomb force produced by inflowing sodium ions, from one sodium ion channel to the next sodium channel would be inversely proportionate to the density of sodium channels on the axon membrane. Because the longitudinal number of sodium ion channel would be proportionate to the square root of channel density, the conduction velocity of unmyelinated nerves is theoretically shown to be proportionate to the square root of channel density. Also, from a viewpoint of equilibrium state of channel importation and degeneration, channel density was suggested to be proportionate to axonal diameter. Based on these simple basis, conduction velocity in unmyelinated nerves was theoretically shown to be proportionate to the square root of axonal diameter. This new model would also enable us to acquire more accurate and understandable vision on the phenomena in unmyelinated nerves in addition to the conventional electric circuit model and cable theory. PMID:29081751
Use of early tactile stimulation in rehabilitation of digital nerve injuries.
Cheng, A S
2000-01-01
Digital nerves are the most frequently injured peripheral nerve. To improve the recovery of functional sensibility of digital nerve injuries, a prospective randomized controlled study was conducted to see the effect of using early tactile stimulation in rehabilitation of digital nerve injuries. Two specific tactile stimulators were made and prescribed for patients with digital nerve-injury. Twenty-four participants with 32 digital nerve injuries received the prescribed tactile stimulators (experimental group), and another 25 participants with 33 digital nerve injuries received only routine conventional therapy (control group). A significant difference (p < .05) was seen in the experimental group, although there were some variations between the different classes of associated injuries, with least benefit observed in the combined nerve, tendon, and bone injury class. Use of early tactile stimulation as described in this study can be considered an effective way to improve both quality and quantity of recovery of functional sensibility in digital nerve injuries without combined nerve, tendon, and bone injuries.
A need for logical and consistent anatomical nomenclature for cutaneous nerves of the limbs.
Gest, Thomas R; Burkel, William E; Cortright, Gerald W
2009-01-01
The system of anatomical nomenclature needs to be logical and consistent. However, variations in translation to English of the Latin and Greek terminology used in Nomina Anatomica and Terminologia Anatomica have led to some inconsistency in the nomenclature of cutaneous nerves in the limbs. An historical review of cutaneous nerve nomenclature reveals that there are two general naming conventions: one primarily American and one primarily British. The American convention presents cutaneous nerves of the limbs in the format "medial brachial cutaneous nerve," while the British convention presents the same nerve as "medial cutaneous nerve of the arm," thereby translating "brachii" to "of the arm." If logically and consistently applied throughout the body, the British convention would rename the sural nerve to the "nerve of the calf," the brachial artery would become the "artery of the arm," the femoral nerve would be "nerve of the thigh," and femur would be "bone of the thigh" or "thigh bone." The British convention leads to many other nomenclatural inconsistencies, which would seem to make learning anatomy more difficult for the beginning student. In this era of contracting anatomy curricula, every effort should be made to keep anatomical nomenclature simple, logical, and consistent. Copyright 2009 American Association of Anatomists.
Blocking the buccal nerve using two methods of inferior alveolar block injection.
Aker, F D
2001-01-01
The anatomic relations of the buccal nerve branch of the mandibular division of the trigeminal nerve were studied to explain the rationale for the discrepancy in blocking the buccal nerve using two methods of blocking the inferior alveolar nerve, the conventional method and the Gow-Gates method. The conventional method rarely blocks the buccal nerve, while the Gow-Gates method is reported to consistently block the buccal nerve. Eight head and mandibular specimens were dissected to observe the path of buccal nerve and its relationship to the path of needles in the conventional and Gow-Gates techniques. The buccal nerve descends on the medial and then anterior aspect of the deep head of the temporalis muscle (Tdh). At the latter position the buccal nerve enters the retromolar fossa and is encased in a fascial sleeve created by a dense fascial band that spans between the temporalis muscle tendons and the buccinator muscle. At the level of the conventional block injection the buccal nerve was shielded from the path of the needle by the Tdh and the fascial band. In the Gow-Gates block injection, the buccal nerve was exposed on the medial surface of the Tdh, immediately lateral to the path of the needle and proximal to the fascial sleeve. Consequently, the anatomical relations of the buccal nerve in the conventional block method essentially shield the nerve from being bathed by anesthetic solution while in the Gow-Gates method the relations are such that the buccal nerve can be exposed to anesthetic solution and thus blocked, explaining the findings in clinical dentistry. Copyright Wiley-Liss, Inc.
Laser-activated protein solder for peripheral nerve repair
NASA Astrophysics Data System (ADS)
Trickett, Rodney I.; Lauto, Antonio; Dawes, Judith M.; Owen, Earl R.
1995-05-01
A 100 micrometers core optical fiber-coupled 75 mW diode laser operating at a wavelength of 800 nm has been used in conjunction with a protein solder to stripe weld severed rat tibial nerves, reducing the long operating time required for microsurgical nerve repair. Welding is produced by selective laser denaturation of the albumin based solder which contains the dye indocyanine green. Operating time for laser soldering was 10 +/- 5 min. (n equals 20) compared to 23 +/- 9 min. (n equals 10) for microsuturing. The laser solder technique resulted in patent welds with a tensile strength of 15 +/- 5 g, while microsutured nerves had a tensile strength of 40 +/- 10 g. Histopathology of the laser soldered nerves, conducted immediately after surgery, displayed solder adhesion to the outer membrane with minimal damage to the inner axons of the nerves. An in vivo study is under way comparing laser solder repaired tibial nerves to conventional microsuture repair. At the time of submission 15 laser soldered nerves and 7 sutured nerves were characterized at 3 months and showed successful regeneration with compound muscle action potentials of 27 +/- 8 mV and 29 +/- 8 mW respectively. A faster, less damaging and long lasting laser based anastomotic technique is presented.
Sympathetic block by metal clips may be a reversible operation.
Thomsen, Lars L; Mikkelsen, Rasmus T; Derejko, Miroslawa; Schrøder, Henrik D; Licht, Peter B
2014-12-01
Thoracoscopic sympathectomy is now used routinely to treat patients with disabling primary hyperhidrosis or facial blushing. Published results are excellent, but side effects, such as compensatory sweating, are also very frequent. The surgical techniques used and the levels of targeting the sympathetic chain vary tremendously. Most surgeons transect or resect the sympathetic chain, but application of a metal clip that blocks transmission of nerve impulses in the sympathetic chain is used increasingly worldwide. This approach offers potential reversibility if patients regret surgery, but the question of reversibility remains controversial. Two recent experimental studies found severe histological signs of nerve damage 4-6 weeks after clip removal, but they only used conventional histopathological staining methods. Thoracoscopic clipping of the sympathetic trunk was performed in adult sheep, and the clip was removed thoracoscopically after 7 days. Following another 4 weeks (n = 6) or 12 weeks (n = 3), the sympathetic trunks were harvested and analysed by conventional and specific nerve tissue immunohistochemical stains (S100, neurofilament protein and synaptophysin). The contralateral sympathetic chains were used as controls. Conventional and immunohistochemical stains demonstrated severe signs of neural damage on the operated side 4 weeks after clip removal. After 12 weeks, these changes had decreased markedly and conventional histology had almost normalized. Conventional and immunohistochemical stains confirmed that application of metal clips to the sympathetic chain caused severe histological damage in the sympathetic trunk that remained visible 4 weeks after clip removal. However, after 12 weeks, these signs of damage had clearly decreased, which suggests in theory that application of metal clips to the sympathetic chain is a reversible procedure if only the observation period is prolonged. Further studies with longer periods between application and removal as well as investigations of nerve conduction should be encouraged, because we do not know whether histological reversibility at cellular level translates into physiological reversibility and possible correlation of nerve trauma with the duration of the applied clip. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Yang, Jieping; Liu, Wei; Gao, Qinghong
2013-08-01
To evaluate the anesthetic effects and safety of Gow-Gates technique of inferior alveolar nerve block in impacted mandibular third molar extraction. A split-mouth study was designed. The bilateral impacted mandibular third molar of 32 participants were divided into Gow-Gates technique of inferior alveolar nerve block (Gow-Gates group) and conventional technique of inferior alveolar nerve block (conventional group) randomly with third molar extracted. The anesthetic effects and adverse events were recorded. All the participants completed the research. The anesthetic success rate was 96.9% in Gow-Gates group and 90.6% in conventional group with no statistical difference ( P= 0.317); but when comparing the anesthesia grade, Gow-Gates group had a 96.9% of grade A and B, and conventional group had a rate of 78.1% (P = 0.034). And the Gow-Gates group had a much lower withdrawn bleeding than conventional group (P = 0.025). Two groups had no hematoma. Gow-Gates technique had a reliable anesthesia effects and safety in impacted mandibular third molar extraction and could be chosen as a candidate for the conventional inferior alveolar nerve block.
NASA Astrophysics Data System (ADS)
Sabetian, Parisa; Popovic, Milos R.; Yoo, Paul B.
2017-06-01
Objective. Differential measurement of efferent and afferent peripheral nerve activity offers a promising means of improving the clinical utility of implantable neuroprostheses. The tripolar nerve cuff electrode has historically served as the gold standard for achieving high signal-to-noise ratios (SNRs) of the recordings. However, the symmetrical geometry of this electrode array (i.e. electrically-shorted side contacts) precludes it from measuring electrical signals that can be used to obtain directional information. In this study, we investigated the feasibility of using a bipolar nerve cuff electrode to achieve high-SNR of peripheral nerve activity. Approach. A finite element model was implemented to investigate the effects of electrode design parameters—electrode length, electrode edge length (EEL), and a conductive shielding layer (CSL)—on simulated single fiber action potentials (SFAP) and also artifact noise signals (ANS). Main results. Our model revealed that the EEL was particularly effective in increasing the peak-to-peak amplitude of the SFAP (319%) and reducing the common mode ANS (67%) of the bipolar cuff electrode. By adding a CSL to the bipolar cuff electrode, the SNR was found to be 65.2% greater than that of a conventional tripolar cuff electrode. In vivo experiments in anesthetized rats confirmed that a bipolar cuff electrode can achieve a SNR that is 38% greater than that achieved by a conventional tripolar cuff electrode (p < 0.05). Significance. The current study showed that bipolar nerve cuff electrodes can be designed to achieve SNR levels that are comparable to that of tripolar configuration. Further work is needed to confirm that these bipolar design parameters can be used to record bi-directional neural activity in a physiological setting.
Sabetian, Parisa; Popovic, Milos R; Yoo, Paul B
2017-06-01
Differential measurement of efferent and afferent peripheral nerve activity offers a promising means of improving the clinical utility of implantable neuroprostheses. The tripolar nerve cuff electrode has historically served as the gold standard for achieving high signal-to-noise ratios (SNRs) of the recordings. However, the symmetrical geometry of this electrode array (i.e. electrically-shorted side contacts) precludes it from measuring electrical signals that can be used to obtain directional information. In this study, we investigated the feasibility of using a bipolar nerve cuff electrode to achieve high-SNR of peripheral nerve activity. A finite element model was implemented to investigate the effects of electrode design parameters-electrode length, electrode edge length (EEL), and a conductive shielding layer (CSL)-on simulated single fiber action potentials (SFAP) and also artifact noise signals (ANS). Our model revealed that the EEL was particularly effective in increasing the peak-to-peak amplitude of the SFAP (319%) and reducing the common mode ANS (67%) of the bipolar cuff electrode. By adding a CSL to the bipolar cuff electrode, the SNR was found to be 65.2% greater than that of a conventional tripolar cuff electrode. In vivo experiments in anesthetized rats confirmed that a bipolar cuff electrode can achieve a SNR that is 38% greater than that achieved by a conventional tripolar cuff electrode (p < 0.05). The current study showed that bipolar nerve cuff electrodes can be designed to achieve SNR levels that are comparable to that of tripolar configuration. Further work is needed to confirm that these bipolar design parameters can be used to record bi-directional neural activity in a physiological setting.
Inferior alveolar nerve block: Alternative technique
Thangavelu, K.; Kannan, R.; Kumar, N. Senthil
2012-01-01
Background: Inferior alveolar nerve block (IANB) is a technique of dental anesthesia, used to produce anesthesia of the mandibular teeth, gingivae of the mandible and lower lip. The conventional IANB is the most commonly used the nerve block technique for achieving local anesthesia for mandibular surgical procedures. In certain cases, however, this nerve block fails, even when performed by the most experienced clinician. Therefore, it would be advantageous to find an alternative simple technique. Aim and Objective: The objective of this study is to find an alternative inferior alveolar nerve block that has a higher success rate than other routine techniques. To this purpose, a simple painless inferior alveolar nerve block was designed to anesthetize the inferior alveolar nerve. Materials and Methods: This study was conducted in Oral surgery department of Vinayaka Mission's dental college Salem from May 2009 to May 2011. Five hundred patients between the age of 20 years and 65 years who required extraction of teeth in mandible were included in the study. Out of 500 patients 270 were males and 230 were females. The effectiveness of the IANB was evaluated by using a sharp dental explorer in the regions innervated by the inferior alveolar, lingual, and buccal nerves after 3, 5, and 7 min, respectively. Conclusion: This study concludes that inferior alveolar nerve block is an appropriate alternative nerve block to anesthetize inferior alveolar nerve due to its several advantages. PMID:25885503
Inferior alveolar nerve block: Alternative technique.
Thangavelu, K; Kannan, R; Kumar, N Senthil
2012-01-01
Inferior alveolar nerve block (IANB) is a technique of dental anesthesia, used to produce anesthesia of the mandibular teeth, gingivae of the mandible and lower lip. The conventional IANB is the most commonly used the nerve block technique for achieving local anesthesia for mandibular surgical procedures. In certain cases, however, this nerve block fails, even when performed by the most experienced clinician. Therefore, it would be advantageous to find an alternative simple technique. The objective of this study is to find an alternative inferior alveolar nerve block that has a higher success rate than other routine techniques. To this purpose, a simple painless inferior alveolar nerve block was designed to anesthetize the inferior alveolar nerve. This study was conducted in Oral surgery department of Vinayaka Mission's dental college Salem from May 2009 to May 2011. Five hundred patients between the age of 20 years and 65 years who required extraction of teeth in mandible were included in the study. Out of 500 patients 270 were males and 230 were females. The effectiveness of the IANB was evaluated by using a sharp dental explorer in the regions innervated by the inferior alveolar, lingual, and buccal nerves after 3, 5, and 7 min, respectively. This study concludes that inferior alveolar nerve block is an appropriate alternative nerve block to anesthetize inferior alveolar nerve due to its several advantages.
Effect of renal nerve stimulation on responsiveness of the rat renal vasculature.
DiBona, Gerald F; Sawin, Linda L
2002-11-01
When the renal nerves are stimulated with sinusoidal stimuli over the frequency range 0.04-0.8 Hz, low (< or =0.4 Hz)- but not high (> or =0.4 Hz)-frequency oscillations appear in renal blood flow (RBF) and are proposed to increase responsiveness of the renal vasculature to stimuli. This hypothesis was tested in anesthetized rats in which RBF responses to intrarenal injection of norepinephrine and angiotensin and to reductions in renal arterial pressure (RAP) were determined during conventional rectangular pulse and sinusoidal renal nerve stimulation. Conventional rectangular pulse renal nerve stimulation decreased RBF at 2 Hz but not at 0.2 or 1.0 Hz. Sinusoidal renal nerve stimulation elicited low-frequency oscillations (< or =0.4 Hz) in RBF only when the basal carrier signal frequency produced renal vasoconstriction, i.e., at 5 Hz but not at 1 Hz. Regardless of whether renal vasoconstriction occurred, neither conventional rectangular pulse nor sinusoidal renal nerve stimulation altered renal vasoconstrictor responses to norepinephrine and angiotensin. The RBF response to reduction in RAP was altered by both conventional rectangular pulse and sinusoidal renal nerve stimulation only when renal vasoconstriction occurred: the decrease in RBF during reduced RAP was greater. Sinusoidal renal nerve stimulation with a renal vasoconstrictor carrier frequency results in a decrease in RBF with superimposed low-frequency oscillations. However, these low-frequency RBF oscillations do not alter renal vascular responsiveness to vasoconstrictor stimuli.
New synthetic prosthesis for peripheral nerve injuries: an experimental pilot study.
Uranüs, Selman; Bretthauer, Georg; Nagele-Moser, Doris; Saliba, Sarah; Tomasch, Gordana; Rafolt, Dietmar; Justich, Ivo; Waldert, Jörg; Berghold, Andrea; Kleinert, Reinhold; Becker, Heinz; Voges, Udo; Wiederstein-Grasser, Iris; Koch, Horst
2013-04-01
Even the most modern technology has failed to induce satisfactory functional regeneration of traumatically severed peripheral nerves. Delayed neural regeneration and in consequence, slower neural conduction seriously limit muscle function in the area supplied by the injured nerve. This study aimed to compare a new nerve coaptation system involving an innovative prosthesis with the classical clinical method of sutured nerve coaptation. Besides the time and degree of nerve regeneration, the influence of electrostimulation was also tested. The sciatic nerve was severed in 14 female Göttingen minipigs with an average weight of 40.4 kg. The animals were randomized into 2 groups: One group received the new prosthesis and the other underwent microsurgical coaptation. In each group, according to the randomization a part of the animals received postoperative electrostimulation. Postoperative monitoring and the stimulation schedule covered a period of 9 months, during which axonal budding was evaluated monthly. The data from the pilot study indicate that results with the nerve prosthesis were comparable with those of conventional coaptation. The results indicate that implantation of the nerve prosthesis allows for good and effective neural regeneration. This new and simple treatment option for peripheral nerve injuries can be performed in any hospital with surgical facilities as it does not involve the demanding microsurgical suture technique that can only be performed in specialized centers.
Sakakura, Kenichi; Ladich, Elena; Fuimaono, Kristine; Grunewald, Debby; O'Fallon, Patrick; Spognardi, Anna-Maria; Markham, Peter; Otsuka, Fumiyuki; Yahagi, Kazuyuki; Shen, Kai; Kolodgie, Frank D; Joner, Michael; Virmani, Renu
2015-01-01
The long-term efficacy of radiofrequency ablation of renal autonomic nerves has been proven in nonrandomized studies. However, long-term safety of the renal artery (RA) is of concern. The aim of our study was to determine if cooling during radiofrequency ablation preserved the RA while allowing equivalent nerve damage. A total of 9 swine (18 RAs) were included, and allocated to irrigated radiofrequency (n=6 RAs, temperature setting: 50°C), conventional radiofrequency (n=6 RAs, nonirrigated, temperature setting: 65°C), and high-temperature radiofrequency (n=6 RAs, nonirrigated, temperature setting: 90°C) groups. RAs were harvested at 10 days, serially sectioned from proximal to distal including perirenal tissues and examined after paraffin embedding, and staining with hematoxylin-eosin and Movat pentachrome. RAs and periarterial tissue including nerves were semiquantitatively assessed and scored. A total of 660 histological sections from 18 RAs were histologically examined by light microscopy. Arterial medial injury was significantly less in the irrigated radiofrequency group (depth of medial injury, circumferential involvement, and thinning) than that in the conventional radiofrequency group (P<0.001 for circumference; P=0.003 for thinning). Severe collagen damage such as denatured collagen was also significantly less in the irrigated compared with the conventional radiofrequency group (P<0.001). Nerve damage although not statistically different between the irrigated radiofrequency group and conventional radiofrequency group (P=0.36), there was a trend toward less nerve damage in the irrigated compared with conventional. Compared to conventional radiofrequency, circumferential medial damage in highest-temperature nonirrigated radiofrequency group was significantly greater (P<0.001). Saline irrigation significantly reduces arterial and periarterial tissue damage during radiofrequency ablation, and there is a trend toward less nerve damage. © 2014 American Heart Association, Inc.
Cha, Hyun Gyu; Ji, Sang-Goo; Kim, Myoung-Kwon
2016-07-01
[Purpose] The aim of the present study was to determine whether repetitive transcranial magnetic stimulation can improve sensory recovery of the lower extremities in subacute-stage spinal cord injury patients. [Subjects and Methods] This study was conducted on 20 subjects with diagnosed paraplegia due to spinal cord injury. These 20 subjects were allocated to an experimental group of 10 subjects that underwent active repetitive transcranial magnetic stimulation or to a control group of 10 subjects that underwent sham repetitive transcranial magnetic stimulation. The SCI patients in the experimental group underwent active repetitive transcranial magnetic stimulation and conventional rehabilitation therapy, whereas the spinal cord injury patients in the control group underwent sham repetitive transcranial magnetic stimulation and conventional rehabilitation therapy. Participants in both groups received therapy five days per week for six-weeks. Latency, amplitude, and sensory nerve conduction velocity were assessed before and after the six week therapy period. [Results] A significant intergroup difference was observed for posttreatment velocity gains, but no significant intergroup difference was observed for amplitude or latency. [Conclusion] repetitive transcranial magnetic stimulation may be improve sensory recovery of the lower extremities in subacute-stage spinal cord injury patients.
Leclère, F M; Badur, N; Mathys, L; Vögelin, E
2015-08-01
Persistent traumatic peroneal nerve palsy, following nerve surgery failure, is usually treated by tendon transfer or more recently by tibial nerve transfer. However, when there is destruction of the tibial anterior muscle, an isolated nerve transfer is not possible. In this article, we present the key steps and surgical tips for the Ninkovic procedure including transposition of the neurotized lateral gastrocnemius muscle with the aim of restoring active voluntary dorsiflexion. The transposition of the lateral head of the gastrocnemius muscle to the tendons of the anterior tibial muscle group, with simultaneous transposition of the intact proximal end of the deep peroneal nerve to the tibial nerve of the gastrocnemius muscle by microsurgical neurorrhaphy is performed in one stage. It includes 10 key steps which are described in this article. Since 1994, three clinical series have highlighted the advantages of this technique. Functional and subjective results are discussed. We review the indications and limitations of the technique. Early clinical results after neurotized lateral gastrocnemius muscle transfer appear excellent; however, they still need to be compared with conventional tendon transfer procedures. Clinical studies are likely to be conducted in this area largely due to the frequency of persistant peroneal nerve palsy and the limitations of functional options in cases of longstanding peripheral nerve palsy, anterior tibial muscle atrophy or destruction. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
2009-01-01
Neural tissue repair and regeneration strategies have received a great deal of attention because it directly affects the quality of the patient's life. There are many scientific challenges to regenerate nerve while using conventional autologous nerve grafts and from the newly developed therapeutic strategies for the reconstruction of damaged nerves. Recent advancements in nerve regeneration have involved the application of tissue engineering principles and this has evolved a new perspective to neural therapy. The success of neural tissue engineering is mainly based on the regulation of cell behavior and tissue progression through the development of a synthetic scaffold that is analogous to the natural extracellular matrix and can support three-dimensional cell cultures. As the natural extracellular matrix provides an ideal environment for topographical, electrical and chemical cues to the adhesion and proliferation of neural cells, there exists a need to develop a synthetic scaffold that would be biocompatible, immunologically inert, conducting, biodegradable, and infection-resistant biomaterial to support neurite outgrowth. This review outlines the rationale for effective neural tissue engineering through the use of suitable biomaterials and scaffolding techniques for fabrication of a construct that would allow the neurons to adhere, proliferate and eventually form nerves. PMID:19939265
Laser-activated protein bands for peripheral nerve repair
NASA Astrophysics Data System (ADS)
Lauto, Antonio; Trickett, Rodney I.; Malik, Richard; Dawes, Judith M.; Owen, Earl R.
1996-01-01
A 100 micrometer core optical fiber-coupled 75 mW diode laser operating at a wavelength of 800 nm has been used in conjunction with a protein solder to stripe weld severed rat tibial nerves, reducing the long operating time required for microsurgical nerve repair. Welding is produced by selective laser denaturation of the protein based solder which contains the dye indocyanine green. Operating time for laser soldering was 10 plus or minus 5 min. (n equals 24) compared to 23 plus or minus 9 min (n equals 13) for microsuturing. The laser solder technique resulted in patent welds with a tensile strength of 15 plus or minus 5 g, while microsutured nerves had a tensile strength of 40 plus or minus 10 g. Histopathology of the laser soldered nerves, conducted immediately after surgery, displayed solder adhesion to the outer membrane with minimal damage to the inner axons of the nerves. An in vivo study, with a total of fifty-seven adult male wistar rats, compared laser solder repaired tibial nerves to conventional microsuture repair. Twenty-four laser soldered nerves and thirteen sutured nerves were characterized at three months and showed successful regeneration with average compound muscle action potentials (CMAP) of 2.4 plus or minus 0.7 mV and 2.7 plus or minus 0.8 mV respectively. Histopathology of the in vivo study, confirmed the comparable regeneration of axons in laser and suture operated nerves. A faster, less damaging and long lasting laser based anastomotic technique is presented.
Thomeer, Henricus; Kunst, Henricus; Verbist, Berit; Cremers, Cor
2012-07-01
To describe the audiometric results in a consecutive series of patients with congenital ossicular aplasia (Class 4a) or dysplasia of the oval and/or round window (Class 4b), which might include a possible anomalous course of the facial nerve. Retrospective chart study. Tertiary referral center. A tertiary referral center study with a total of 14 patients with congenital minor ear anomalies as part of a consecutive series (n = 89) who underwent exploratory tympanotomies (15 ears). Audiometric results. In 8 of 15 ears, ossicular reconstruction was attempted. In the short term (1 mo), there was a serviceable hearing outcome (air-bone gap closure to within 25 dB) in 4 ears. However, the long-term results showed deterioration because of an increased air-bone gap in all but 1 ear. No facial nerve lesion was observed postoperatively. Congenital dysplasia or aplasia of the oval and/or round window is an uncommon congenital minor ear anomaly. Classical microsurgical opportunities are rare in this group of anomalies. Newer options for hearing rehabilitation, such as the osseointegrated passive bone conduction devices, have become viable alternatives for conventional air conduction hearing devices. In the near future, upcoming active bone conduction devices might become the most preferred surgical option. In cases in which the facial nerve is only partially overlying the oval window, a type of malleostapedotomy procedure might result in a serviceable postoperative hearing level.
Vaginal blood flow after radical hysterectomy with and without nerve sparing. A preliminary report.
Pieterse, Q D; Ter Kuile, M M; Deruiter, M C; Trimbos, J B M Z; Kenter, G G; Maas, C P
2008-01-01
Radical hysterectomy with pelvic lymphadenectomy (RHL) for cervical cancer causes damage to the autonomic nerves, which are responsible for increased vaginal blood flow during sexual arousal. The aim of the study of which we now report preliminary data was to determine whether a nerve-sparing technique leads to an objectively less disturbed vaginal blood flow response during sexual stimulation. Photoplethysmographic assessment of vaginal pulse amplitude (VPA) during sexual stimulation by erotic films was performed. Subjective sexual arousal was assessed after each stimulus. Thirteen women after conventional RHL, 10 women after nerve-sparing RHL, and 14 healthy premenopausal women participated. Data were collected between January and August 2006. The main outcome measure was the logarithmically transformed mean VPA. To detect statistically significant differences in mean VPA levels between the three groups, a univariate analysis of variance was used. Mean VPA differed between the three groups (P= 0.014). The conventional group had a lower vaginal blood flow response than the control group (P= 0.016), which tended also to be lower than that of the nerve-sparing group (P= 0.097). These differences were critically dependent on baseline vaginal blood flow differences between the groups. The conventional group follows a vaginal blood flow pattern similar to postmenopausal women. Conventional RHL is associated with an overall disturbed vaginal blood flow response compared with healthy controls. Because it is not observed to the same extent after nerve-sparing RHL, it seems that the nerve-sparing technique leads to a better overall vaginal blood flow caused by less denervation of the vagina.
Large Extremity Peripheral Nerve Repair
2013-10-01
can provide fixation strengths approaching that of conventional microsurgery and that the PTB repair is unlikely to be disturbed in vivo. The...of nerve wrap biomaterial during long periods of recovery associated with large nerve deficit reconstruction and long nerve grafts. As with the...PTB/xHAM wrap compared to standard (suture) of care microsurgery . Demonstrated improved nerve regeneration in a muscle mass retention model
Non-invasive peripheral nerve stimulation via focused ultrasound in vivo
NASA Astrophysics Data System (ADS)
Downs, Matthew E.; Lee, Stephen A.; Yang, Georgiana; Kim, Seaok; Wang, Qi; Konofagou, Elisa E.
2018-02-01
Focused ultrasound (FUS) has been employed on a wide range of clinical applications to safely and non-invasively achieve desired effects that have previously required invasive and lengthy procedures with conventional methods. Conventional electrical neuromodulation therapies that are applied to the peripheral nervous system (PNS) are invasive and/or non-specific. Recently, focused ultrasound has demonstrated the ability to modulate the central nervous system and ex vivo peripheral neurons. Here, for the first time, noninvasive stimulation of the sciatic nerve eliciting a physiological response in vivo is demonstrated with FUS. FUS was applied on the sciatic nerve in mice with simultaneous electromyography (EMG) on the tibialis anterior muscle. EMG signals were detected during or directly after ultrasound stimulation along with observable muscle contraction of the hind limb. Transecting the sciatic nerve downstream of FUS stimulation eliminated EMG activity during FUS stimulation. Peak-to-peak EMG response amplitudes and latency were found to be comparable to conventional electrical stimulation methods. Histology along with behavioral and thermal testing did not indicate damage to the nerve or surrounding regions. The findings presented herein demonstrate that FUS can serve as a targeted, safe and non-invasive alternative to conventional peripheral nervous system stimulation to treat peripheral neuropathic diseases in the clinic.
Multispectral photoacoustic imaging of nerves with a clinical ultrasound system
NASA Astrophysics Data System (ADS)
Mari, Jean Martial; West, Simeon; Beard, Paul C.; Desjardins, Adrien E.
2014-03-01
Accurate and efficient identification of nerves is of great importance during many ultrasound-guided clinical procedures, including nerve blocks and prostate biopsies. It can be challenging to visualise nerves with conventional ultrasound imaging, however. One of the challenges is that nerves can have very similar appearances to nearby structures such as tendons. Several recent studies have highlighted the potential of near-infrared optical spectroscopy for differentiating nerves and adjacent tissues, as this modality can be sensitive to optical absorption of lipids that are present in intra- and extra-neural adipose tissue and in the myelin sheaths. These studies were limited to point measurements, however. In this pilot study, a custom photoacoustic system with a clinical ultrasound imaging probe was used to acquire multi-spectral photoacoustic images of nerves and tendons from swine ex vivo, across the wavelength range of 1100 to 1300 nm. Photoacoustic images were processed and overlaid in colour onto co-registered conventional ultrasound images that were acquired with the same imaging probe. A pronounced optical absorption peak centred at 1210 nm was observed in the photoacoustic signals obtained from nerves, and it was absent in those obtained from tendons. This absorption peak, which is consistent with the presence of lipids, provides a novel image contrast mechanism to significantly enhance the visualization of nerves. In particular, image contrast for nerves was up to 5.5 times greater with photoacoustic imaging (0.82 +/- 0.15) than with conventional ultrasound imaging (0.148 +/- 0.002), with a maximum contrast of 0.95 +/- 0.02 obtained in photoacoustic mode. This pilot study demonstrates the potential of photoacoustic imaging to improve clinical outcomes in ultrasound-guided interventions in regional anaesthesia and interventional oncology.
Large Extremity Peripheral Nerve Repair
2013-10-01
approaching that of conventional microsurgery and that the PTB repair is unlikely to be disturbed in vivo. The results in Figure 5 were obtained with...with large nerve deficit reconstruction and long nerve grafts. As with the human amnion nerve wraps, it was important for us to confirm that, in...xHAM wrap compared to standard (suture) of care microsurgery . Demonstrated improved nerve regeneration in a muscle mass retention model
Large Extremity Peripheral Nerve Repair
2013-10-01
show that the PTB method can provide fixation strengths approaching that of conventional microsurgery and that the PTB repair is unlikely to be...biomaterial during long periods of recovery associated with large nerve deficit reconstruction and long nerve grafts. As with the human amnion nerve...functional recovery model (SFI, sciatic function index) using PTB/xHAM wrap compared to standard (suture) of care microsurgery . Demonstrated improved nerve
Hussain, Gauhar; Rizvi, S Aijaz Abbas; Singhal, Sangeeta; Zubair, Mohammad; Ahmad, Jamal
2014-01-01
To study the nerve conduction velocity in clinically undetectable and detectable peripheral neuropathy in type 2 diabetes mellitus with variable duration. This cross sectional study was conducted in diagnosed type 2 diabetes mellitus patients. They were divided in groups: Group I (n=37) with clinically detectable diabetic peripheral neuropathy of shorter duration and Group II (n=27) with clinically detectable diabetic peripheral neuropathy of longer duration. They were compared with T2DM patients (n=22) without clinical neuropathy. Clinical diagnosis was based on neuropathy symptom score (NSS) and neuropathy disability score (NDS) for signs. Nerve conduction velocity was measured in both upper and lower limbs. Median, ulnar, common peroneal and posterior tibial nerves were selected for motor nerve conduction study and median and sural nerves were selected for sensory nerve conduction study. The comparisons were done between nerve conduction velocities of motor and sensory nerves in patients of clinically detectable neuropathy and patients without neuropathy in type 2 diabetes mellitus population. This study showed significant electrophysiological changes with duration of disease. Nerve conduction velocities in lower limbs were significantly reduced even in patients of shorter duration with normal upper limb nerve conduction velocities. Diabetic neuropathy symptom score (NSS) and neuropathy disability score (NDS) can help in evaluation of diabetic sensorimotor polyneuropathy though nerve conduction study is more powerful test and can help in diagnosing cases of neuropathy. Copyright © 2013 Diabetes India. Published by Elsevier Ltd. All rights reserved.
Kottink, Anke I R; Tenniglo, Martin J B; de Vries, Wiebe H K; Hermens, Hermie J; Buurke, Jaap H
2012-01-01
The aims of this study were: (i) to compare the neuro-prosthetic effect of implantable peroneal nerve stimulation to the orthotic effect of a standard of care intervention (no device, shoe or ankle foot orthosis) on walking, as assessed by spatiotemporal parameters; and (ii) to examine whether there is evidence of an enhanced lower-limb flexion reflex with peroneal nerve stimulation and compare the kinematic effect of an implantable peroneal nerve stimulation device vs standard of care intervention on initial loading response of the paretic limb, as assessed by hip, knee and ankle kinematics. Randomized controlled trial. A total of 23 chronic stroke survivors with drop foot. The intervention group received an implantable 2-channel peroneal nerve stimulator for correction of drop foot. The control group continued using a conventional walking device. Spatiotemporal parameters and hip, knee and ankle kinematics were measured while subjects walked with the device on using a 3-dimensional video camera system during baseline and after a follow-up period of 26 weeks. Peroneal nerve stimulation normalized stance and double support of the paretic limb and single support of the non-paretic limb, in comparison with using a conventional walking device. In addition, peroneal nerve stimulation is more effective to provide ankle dorsiflexion during swing and resulted in a normalized initial loading response. Although peroneal nerve stimulation and ankle foot orthosis are both prescribed to correct a drop foot in the same patient population, spatiotemporal parameters, dorsiflexion during swing and loading response are influenced in a functionally different way.
A basic review on the inferior alveolar nerve block techniques.
Khalil, Hesham
2014-01-01
The inferior alveolar nerve block is the most common injection technique used in dentistry and many modifications of the conventional nerve block have been recently described in the literature. Selecting the best technique by the dentist or surgeon depends on many factors including the success rate and complications related to the selected technique. Dentists should be aware of the available current modifications of the inferior alveolar nerve block techniques in order to effectively choose between these modifications. Some operators may encounter difficulty in identifying the anatomical landmarks which are useful in applying the inferior alveolar nerve block and rely instead on assumptions as to where the needle should be positioned. Such assumptions can lead to failure and the failure rate of inferior alveolar nerve block has been reported to be 20-25% which is considered very high. In this basic review, the anatomical details of the inferior alveolar nerve will be given together with a description of its both conventional and modified blocking techniques; in addition, an overview of the complications which may result from the application of this important technique will be mentioned.
A basic review on the inferior alveolar nerve block techniques
Khalil, Hesham
2014-01-01
The inferior alveolar nerve block is the most common injection technique used in dentistry and many modifications of the conventional nerve block have been recently described in the literature. Selecting the best technique by the dentist or surgeon depends on many factors including the success rate and complications related to the selected technique. Dentists should be aware of the available current modifications of the inferior alveolar nerve block techniques in order to effectively choose between these modifications. Some operators may encounter difficulty in identifying the anatomical landmarks which are useful in applying the inferior alveolar nerve block and rely instead on assumptions as to where the needle should be positioned. Such assumptions can lead to failure and the failure rate of inferior alveolar nerve block has been reported to be 20-25% which is considered very high. In this basic review, the anatomical details of the inferior alveolar nerve will be given together with a description of its both conventional and modified blocking techniques; in addition, an overview of the complications which may result from the application of this important technique will be mentioned. PMID:25886095
Viera Alemán, C; Purón, E; Hamilton, M L; Santos Anzorandia, C; Navarro, A; Pineda Ortiz, I
The treatment selection in the carpal tunnel syndrome according to the damage of the median nerve is important and all of these have adverse effects. A good alternative without undesired reactions is irradiation of the carpal tunnel with not coherent light between 920 and 940 nm emitted by gallium arsenide diodes, resembling the physic and therapeutic laser effects. Twenty-six female patients with idiopathic middle carpal tunnel syndrome were irradiated 15 minutes daily during three weeks. The median nerve motor and sensitive neuroconduction was studied before and immediately after the treatment. The abnormal neuroconduction variables (latency, amplitude and velocity conduction) did not modify when treatment concluded, in spite of all the patients reported disappearance of pain and numbness in damaged hands. Not coherent light does not change the fibers functional state explored by conventional neuroconductions techniques. It remains to know if this light produces fine fibers improvement.
Nerve conduction studies are safe in patients with central venous catheters.
London, Zachary N; Mundwiler, Andrew; Oral, Hakan; Gallagher, Gary W
2017-08-01
It is unknown if central venous catheters bypass the skin's electrical resistance and engender a risk of nerve conduction study-induced cardiac arrhythmia. The objective of this study is to determine if nerve conduction studies affect cardiac conduction and rhythm in patients with central venous catheters. Under continuous 12-lead electrocardiogram monitoring, subjects with and without central venous catheters underwent a series of upper extremity nerve conduction studies. A cardiologist reviewed the electrocardiogram tracings for evidence of cardiac conduction abnormality or arrhythmia. Ten control subjects and 10 subjects with central venous catheters underwent the nerve conduction study protocol. No malignant arrhythmias or conduction abnormalities were noted in either group. Nerve conduction studies of the upper extremities, including both proximal stimulation and repetitive stimulation, do not appear to confer increased risk of cardiac conduction abnormality in those patients with central venous catheters who are not critically ill or have a prior history of arrhythmia. Muscle Nerve 56: 321-323, 2017. © 2016 Wiley Periodicals, Inc.
Generalized cable equation model for myelinated nerve fiber.
Einziger, Pinchas D; Livshitz, Leonid M; Mizrahi, Joseph
2005-10-01
Herein, the well-known cable equation for nonmyelinated axon model is extended analytically for myelinated axon formulation. The myelinated membrane conductivity is represented via the Fourier series expansion. The classical cable equation is thereby modified into a linear second order ordinary differential equation with periodic coefficients, known as Hill's equation. The general internal source response, expressed via repeated convolutions, uniformly converges provided that the entire periodic membrane is passive. The solution can be interpreted as an extended source response in an equivalent nonmyelinated axon (i.e., the response is governed by the classical cable equation). The extended source consists of the original source and a novel activation function, replacing the periodic membrane in the myelinated axon model. Hill's equation is explicitly integrated for the specific choice of piecewise constant membrane conductivity profile, thereby resulting in an explicit closed form expression for the transmembrane potential in terms of trigonometric functions. The Floquet's modes are recognized as the nerve fiber activation modes, which are conventionally associated with the nonlinear Hodgkin-Huxley formulation. They can also be incorporated in our linear model, provided that the periodic membrane point-wise passivity constraint is properly modified. Indeed, the modified condition, enforcing the periodic membrane passivity constraint on the average conductivity only leads, for the first time, to the inclusion of the nerve fiber activation modes in our novel model. The validity of the generalized transmission-line and cable equation models for a myelinated nerve fiber, is verified herein through a rigorous Green's function formulation and numerical simulations for transmembrane potential induced in three-dimensional myelinated cylindrical cell. It is shown that the dominant pole contribution of the exact modal expansion is the transmembrane potential solution of our generalized model.
Charles, Morten; Soedamah-Muthu, Sabita S.; Tesfaye, Solomon; Fuller, John H.; Arezzo, Joseph C.; Chaturvedi, Nishi; Witte, Daniel R.
2010-01-01
OBJECTIVE Slow nerve conduction velocity and reduction in response amplitude are objective hallmarks of diabetic sensorimotor polyneuropathy. Because subjective or clinical indicators of neuropathy do not always match well with the presence of abnormal nerve physiology tests, we evaluated associations to nerve conduction in patients with type 1 diabetes. RESEARCH DESIGN AND METHODS Nerve conduction studies were performed in the distal sural and ulnar sensory nerves and the peroneal motor nerve in 456 individuals with type 1 diabetes who participated in the follow-up visit of the EURODIAB Prospective Complications Study (EPCS). We used multivariate regression models to describe associations to decreased nerve conduction measures. RESULTS In addition to an effect of duration of diabetes and A1C, which were both associated with low nerve conduction velocity and response amplitude, we found that the presence of nephropathy, retinopathy, or a clinical diagnosis of neuropathy was associated with low nerve conduction velocity and amplitude. In the case of nonproliferative retinopathy, the odds ratio (OR) for being in lowest tertile was 2.30 (95% CI 1.13–4.67) for nerve conduction velocity. A similar OR was found for each 2% difference in A1C (2.39 [1.68–3.41]). CONCLUSIONS We show that the presence of other microvascular diabetes complications, together with diabetes duration and A1C, are associated with low nerve conduction velocity and amplitude response and that cardiovascular disease or risk factors do not seem to be associated with these measures. PMID:20823346
Casanova, I; Diaz, A; Pinto, S; de Carvalho, M
2014-04-01
The technique of threshold tracking to test axonal excitability gives information about nodal and internodal ion channel function. We aimed to investigate variability of the motor excitability measurements in healthy controls, taking into account age, gender, body mass index (BMI) and small changes in skin temperature. We examined the left median nerve of 47 healthy controls using the automated threshold-tacking program, QTRAC. Statistical multiple regression analysis was applied to test relationship between nerve excitability measurements and subject variables. Comparisons between genders did not find any significant difference (P>0.2 for all comparisons). Multiple regression analysis showed that motor amplitude decreases with age and temperature, stimulus-response slope decreases with age and BMI, and that accommodation half-time decrease with age and temperature. The changes related to demographic features on TRONDE protocol parameters are small and less important than in conventional nerve conduction studies. Nonetheless, our results underscore the relevance of careful temperature control, and indicate that interpretation of stimulus-response slope and accommodation half-time should take into account age and BMI. In contrast, gender is not of major relevance to axonal threshold findings in motor nerves. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Electromyographic studies of motor control in humans.
Shahani, B T; Wierzbicka, M M
1987-11-01
Electromyography and electroneurography have proved to be useful in investigation and understanding of a variety of neurologic disorders. In most laboratories, however, these electrodiagnostic techniques have been used to help in the diagnosis of diseases that affect the peripheral nerves, neuromuscular junctions, or skeletal muscle fibers. Although major advances in electronic and computer technology have made it possible to study, quantitate, and document reflex activity in intact human subjects, most neurologists still rely on gross clinical observations and most electromyographers continue to use conventional techniques of EMG and nerve conduction studies to differentiate "myopathy" from "neuropathy." This article is a review of some of the electromyographic techniques that have been used in the authors' laboratory for the study of normal and abnormal motor control in man and the treatment of patients with disorders of motor control.
Jiang, Yuebo; Shi, Xian; Tang, Yan
2015-01-01
Acupuncture is one of the important parts of therapeutic methods in traditional Chinese medicine, and has been widely used for the treatment of nerve deafness in recent years. The current study was to evaluate the efficacy and safety of acupuncture therapy for nerve deafness compared with conventional medicine therapy. PubMed, the Chinese National Knowledge Infrastructure Database, the Chinese Science and Technology Periodical Database, the Chinese Biomedical Database, the Wanfang Database were searched for articles published to identify randomized controlled trials evaluating efficacy and side effects between acupuncture and conventional medicine therapies up to 2013/06. A total of 12 studies, including 527 patients assessed the efficacy and safety of acupuncture therapy for nerve deafness. Overall, the efficacy of acupuncture was significantly better than that of the conventional western medication (RR: 1.54, 95% CI: 1.36-1.74) or traditional Chinese medicines (RR: 1.51, 95% CI: 1.24-1.84), and the efficacy of acupuncture in combination with conventional western medication or traditional Chinese medicine was better than that of the conventional western medication alone (RR: 1.51, 95% CI: 1.29-1.77) or traditional Chinese medicine alone (RR: 1.59, 95% CI: 1.30-1.95). Based on the comparison of number of deafness patients who were completely cured, the efficacy of acupuncture in combination with traditional Chinese medicines was better than that of traditional Chinese medicine alone (RR: 4.62, 95% CI: 1.38-15.47). Acupuncture therapy can significantly improve the hearing of patients with nerve deafness, and the efficacy of acupuncture in combination with medication is superior to medication alone.
Winter, Karsten; Strom, Alexander; Zhivov, Andrey; Allgeier, Stephan; Papanas, Nikolaos; Ziegler, Iris; Brüggemann, Jutta; Ringel, Bernd; Peschel, Sabine; Köhler, Bernd; Stachs, Oliver; Guthoff, Rudolf F.; Roden, Michael
2017-01-01
Corneal confocal microscopy (CCM) has revealed reduced corneal nerve fiber (CNF) length and density (CNFL, CNFD) in patients with diabetes, but the spatial pattern of CNF loss has not been studied. We aimed to determine whether spatial analysis of the distribution of corneal nerve branching points (CNBPs) may contribute to improving the detection of early CNF loss. We hypothesized that early CNF decline follows a clustered rather than random distribution pattern of CNBPs. CCM, nerve conduction studies (NCS), and quantitative sensory testing (QST) were performed in a cross-sectional study including 86 patients recently diagnosed with type 2 diabetes and 47 control subjects. In addition to CNFL, CNFD, and branch density (CNBD), CNBPs were analyzed using spatial point pattern analysis (SPPA) including 10 indices and functional statistics. Compared to controls, patients with diabetes showed lower CNBP density and higher nearest neighbor distances, and all SPPA parameters indicated increased clustering of CNBPs (all P<0.05). SPPA parameters were abnormally increased >97.5th percentile of controls in up to 23.5% of patients. When combining an individual SPPA parameter with CNFL, ≥1 of 2 indices were >99th or <1st percentile of controls in 28.6% of patients compared to 2.1% of controls, while for the conventional CNFL/CNFD/CNBD combination the corresponding rates were 16.3% vs 2.1%. SPPA parameters correlated with CNFL and several NCS and QST indices in the controls (all P<0.001), whereas in patients with diabetes these correlations were markedly weaker or lost. In conclusion, SPPA reveals increased clustering of early CNF loss and substantially improves its detection when combined with a conventional CCM measure in patients with recently diagnosed type 2 diabetes. PMID:28296936
Wang, Peiji; Zhao, Jiaju; Jiang, Bo; Zhang, Yong
2015-05-01
Although epineurium neurorrhaphy is the most reliable and conventional method for the repair of peripheral nerve injury and is accepted as the gold standard, it is still far from ideal. Many attempts have been made to develop nerve anastomosis techniques. The aim of this study was to investigate the use of small gap anastomosis performed by cutting and sleeve jointing the epineurium for nerve repair. A 12-week study was performed using small gap anastomosis via cutting and sleeve jointing the epineurium, compared with epineurium neurorrhaphy in situ, to repair a rat sciatic nerve rupture. Three experimental groups were included: sham control (n = 8), small gap anastomosis (n = 16), and epineurium neurorrhaphy (n = 16). About 12 weeks after surgery, recovery was assessed with walking track analysis, electrophysiology, hematoxylin and eosin staining, immunohistochemistry, and electron microscopy. The sciatic nerve functional index observed in the small gap anastomosis group was significantly higher than that in the epineurium neurorrhaphy group (p < 0.05). In vivo electrophysiological analysis confirmed that the small gap anastomosis group showed a significantly higher conduction velocity than the epineurium neurorrhaphy group (p < 0.05). Postoperative morphometric analysis revealed better results after small gap anastomosis compared with epineurium neurorrhaphy. Small gap anastomosis via cutting and sleeve jointing the epineurium could be an alternative to epineurium neurorrhaphy for the repair of peripheral nerve injury, particularly, considering that the epineurium originates from native tissue that provides a suitable microenvironment for the selective regeneration of axons. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Boonsiriseth, K; Sirintawat, N; Arunakul, K; Wongsirichat, N
2013-07-01
This study aimed to evaluate the efficacy of anesthesia obtained with a novel injection approach for inferior alveolar nerve block compared with the conventional injection approach. 40 patients in good health, randomly received each of two injection approaches of local anesthetic on each side of the mandible at two separate appointments. A sharp probe and an electric pulp tester were used to test anesthesia before injection, after injection when the patients' sensation changed, and 5 min after injection. This study comprised positive aspiration and intravascular injection 5% and neurovascular bundle injection 7.5% in the conventional inferior alveolar nerve block, but without occurrence in the novel injection approach. A visual analog scale (VAS) pain assessment was used during injection and surgery. The significance level used in the statistical analysis was p<0.05. For the novel injection approach compared with the conventional injection approach, no significant difference was found on the subjective onset, objective onset, operation time, duration of anesthesia and VAS pain score during operation, but the VAS pain score during injection was significantly different. The efficacy of inferior alveolar nerve block by the novel injection approach provided adequate anesthesia and caused less pain and greater safety during injection. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Klein, Silvan M; Vykoukal, Jody; Li, De-Pei; Pan, Hui-Lin; Zeitler, Katharina; Alt, Eckhard; Geis, Sebastian; Felthaus, Oliver; Prantl, Lukas
2016-07-01
Conduits preseeded with either Schwann cells or stem cells differentiated into Schwann cells demonstrated promising results for the outcome of nerve regeneration in nerve defects. The concept of this trial combines nerve repair by means of a commercially available nerve guidance conduit and preseeding with autologous, undifferentiated, adipose tissue-derived stem cells. Adipose tissue-derived stem cells were harvested from rats and subsequently seeded onto a U.S. Food and Drug Administration-approved type I collagen conduit. Sciatic nerve gaps 10 mm in length were created, and nerve repair was performed by the transplantation of either conduits preseeded with autologous adipose tissue-derived stem cells or acellular (control group) conduits. After 6 months, the motor and sensory nerve conduction velocity were assessed. Nerves were removed and examined by hematoxylin and eosin, van Gieson, and immunohistochemistry (S100 protein) staining for the quality of axonal regeneration. Nerve gaps treated with adipose tissue-derived stem cells showed superior nerve regeneration, reflected by higher motor and sensory nerve conduction velocity values. The motor and sensory nerve conduction velocity were significantly greater in nerves treated with conduits preseeded with adipose tissue-derived stem cells than in nerves treated with conduits alone (p < 0.05). Increased S100 immunoreactivity was detected for the adipose tissue-derived stem cell group. In this group, axon arrangement inside the conduits was more organized. Transplantation of adipose tissue-derived stem cells significantly improves motor and sensory nerve conduction velocity in peripheral nerve gaps. Preseeded conduits showed a more organized axon arrangement inside the conduit in comparison with nerve conduits alone. The approach used here could readily be translated into a clinical therapy. Therapeutic, V.
Odabasi, Zeki; Oh, Shin J
2018-03-01
In this study we report the diagnostic value of the near-nerve needle sensory nerve conduction study (NNN-SNCS) in sensory inflammatory demyelinating polyneuropathy (IDP) in which the routine nerve conduction study was normal or non-diagnostic. The NNN-SNCS was performed to identify demyelination in the plantar nerves in 14 patients and in the median or ulnar nerve in 2 patients with sensory IDP. In 16 patients with sensory IDP, routine NCSs were either normal or non-diagnostic for demyelination. Demyelination was identified by NNN-SNCS by dispersion and/or slow nerve conduction velocity (NCV) below the demyelination marker. Immunotherapy was initiated in 11 patients, 10 of whom improved or remained stable. NNN-SNCS played an essential role in identifying demyelinaton in 16 patients with sensory IDP, leading to proper treatment. Muscle Nerve 57: 414-418, 2018. © 2017 Wiley Periodicals, Inc.
Nerve transection repair using laser-activated chitosan in a rat model.
Bhatt, Neel K; Khan, Taleef R; Mejias, Christopher; Paniello, Randal C
2017-08-01
Cranial nerve transection during head and neck surgery is conventionally repaired with microsuture. Previous studies have demonstrated recovery with laser nerve welding (LNW), a novel alternative to microsuture. LNW has been reported to have poorer tensile strength, however. Laser-activated chitosan, an adhesive biopolymer, may promote nerve recovery while enhancing the tensile strength of the repair. Using a rat posterior tibial nerve injury model, we compared four different methods of nerve repair in this pilot study. Animal study. Animals underwent unilateral posterior tibial nerve transection. The injury was repaired by potassium titanyl phosphate (KTP) laser alone (n = 20), KTP + chitosan (n = 12), microsuture + chitosan (n = 12), and chitosan alone (n = 14). Weekly walking tracks were conducted to measure functional recovery (FR). Tensile strength (TS) was measured at 6 weeks. At 6 weeks, KTP laser alone had the best recovery (FR = 93.4% ± 8.3%). Microsuture + chitosan, KTP + chitosan, and chitosan alone all showed good FR (87.4% ± 13.5%, 84.6% ± 13.0%, and 84.1% ± 10.0%, respectively). One-way analysis of variance was performed (F(3,56) = 2.6, P = .061). A TS threshold of 3.8 N was selected as a control mean recovery. Three groups-KTP alone, KTP + chitosan, and microsuture + chitosan-were found to meet threshold 60% (95% confidence interval [CI]: 23.1%-88.3%), 75% (95% CI: 46.8%-91.1%), and 100% (95% CI: 75.8%-100.0%), respectively. In the posterior tibial nerve model, all repair methods promoted nerve recovery. Laser-activated chitosan as a biopolymer anchor provided good TS and appears to be a novel alternative to microsuture. This repair method may have surgical utility following cranial nerve injury during head and neck surgery. NA Laryngoscope, 127:E253-E257, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Differential aging of median and ulnar sensory nerve parameters.
Werner, Robert A; Franzblau, Alfred; D'Arcy, Hannah J S; Evanoff, Bradley A; Tong, Henry C
2012-01-01
Nerve conduction velocity slows and amplitude declines with aging. Median and ulnar sensory nerves were tested at the annual meetings of the American Dental Association. Seven hundred four subjects had at least two observations. The rate of change in the nerve parameters was estimated while controlling for gender, age, change in hand temperature, baseline body mass index (BMI), and change in BMI. Amplitudes of the median sensory nerve action potentials decreased by 0.58 μV per year, whereas conduction velocity decreased at a rate of 0.41 m/s per year. Corresponding values for the ulnar nerve were 0.89 μV and 0.29 m/s per year. The rates of change in amplitudes did not differ, but the median nerve demonstrated a more rapid loss of conduction velocity. The rate of change for the median conduction velocity was higher than previously reported. The rate of change of median conduction velocity was significantly greater than for the ulnar nerve. Copyright © 2011 Wiley Periodicals, Inc.
Ishibashi, S; Yokota, T; Shiojiri, T; Matunaga, T; Tanaka, H; Nishina, K; Hirota, H; Inaba, A; Yamada, M; Kanda, T; Mizusawa, H
2003-05-01
Acute axonal polyneuropathy and Wernicke-Korsakoff encephalopathy developed simultaneously in three patients. Nerve conduction studies (NCS) detected markedly decreased compound muscle action potentials (CMAPs) and sensory nerve action potentials (SNAPs) with minimal conduction slowing; sympathetic skin responses (SSRs) were also notably decreased. Sural nerve biopsies showed only mild axonal degeneration with scattered myelin ovoid formation. The symptoms of neuropathy lessened within two weeks after an intravenous thiamine infusion. CMAPs, SNAPs, and SSRs also increased considerably. We suggest that this is a new type of peripheral nerve impairment: physiological conduction failure with minimal conduction delay due to thiamine deficiency.
Varenika, Vanja; Lutz, Amelie M; Beaulieu, Christopher F; Bucknor, Matthew D
2017-06-01
To determine whether known variant anatomical relationships between the sciatic nerve and piriformis muscle can be identified on routine MRI studies of the hip and to establish their imaging prevalence. Hip MRI studies acquired over a period of 4 years at two medical centers underwent retrospective interpretation. Anatomical relationship between the sciatic nerve and the piriformis muscle was categorized according to the Beaton and Anson classification system. The presence of a split sciatic nerve at the level of the ischial tuberosity was also recorded. A total of 755 consecutive scans were reviewed. Conventional anatomy (type I), in which an undivided sciatic nerve passes below the piriformis muscle, was identified in 87% of cases. The remaining 13% of cases demonstrated a type II pattern in which one division of the sciatic nerve passes through the piriformis whereas the second passes below. Only two other instances of variant anatomy were identified (both type III). Most variant cases were associated with a split sciatic nerve at the level of the ischial tuberosity (73 out of 111, 65.8%). By contrast, only 6% of cases demonstrated a split sciatic nerve at this level in the context of otherwise conventional anatomy. Anatomical variations of the sciatic nerve course in relation to the piriformis muscle are frequently identified on routine MRI of the hips, occurring in 12-20% of scans reviewed. Almost all variants identified were type II. The ability to recognize variant sciatic nerve courses on MRI may prove useful in optimal treatment planning.
Large Extremity Peripheral Nerve Repair
2014-10-01
Shahani B. Peripheral-nerve allotransplantation in rats immunosuppressed with transient or long-term FK-506. Journal of reconstructive microsurgery ...multicenter study of utilization and outcomes in sensory, mixed, and motor nerve reconstructions . Microsurgery . 2012 Jan;32(1):1-14. PubMed PMID: 22121093...PTB method can provide fixation strengths 6 approaching that of conventional microsurgery and that the PTB repair is unlikely to be disturbed in
Nerve excitability (NE) testing is a sensitive method to test for peripheral neurotoxicity in humans,and may be more sensitive than compound nerve action potential (CNAP) or nerve conduction velocity (NCV).We used acrylamide to compare the NE and CNAP/NCV methods. Behavioral test...
Sunada, Katsuhisa
2015-01-01
Background Conventional anesthetic nerve block injections into the mandibular foramen risk causing nerve damage. This study aimed to compare the efficacy and safety of the anterior technique (AT) of inferior alveolar nerve block using felypressin-propitocaine with a conventional nerve block technique (CT) using epinephrine and lidocaine for anesthesia via the mandibular foramen. Methods Forty healthy university students with no recent dental work were recruited as subjects and assigned to two groups: right side CT or right side AT. Anesthesia was evaluated in terms of success rate, duration of action, and injection pain. These parameters were assessed at the first incisor, premolar, and molar, 60 min after injection. Chi-square and unpaired t-tests were used for statistical comparisons, with a P value of < 0.05 designating significance. Results The two nerve block techniques generated comparable success rates for the right mandible, with rates of 65% (CT) and 60% (AT) at both the first molar and premolar, and rates of 60% (CT) and 50% (AT) at the lateral incisor. The duration of anesthesia using the CT was 233 ± 37 min, which was approximately 40 min shorter than using the AT. This difference was statistically significant (P < 0.05). Injection pain using the AT was rated as milder compared with the CT. This difference was also statistically significant (P < 0.05). Conclusions The AT is no less successful than the CT for inducing anesthesia, and has the added benefits of a significantly longer duration of action and significantly less pain. PMID:28879260
Shinzaki, Hazuki; Sunada, Katsuhisa
2015-06-01
Conventional anesthetic nerve block injections into the mandibular foramen risk causing nerve damage. This study aimed to compare the efficacy and safety of the anterior technique (AT) of inferior alveolar nerve block using felypressin-propitocaine with a conventional nerve block technique (CT) using epinephrine and lidocaine for anesthesia via the mandibular foramen. Forty healthy university students with no recent dental work were recruited as subjects and assigned to two groups: right side CT or right side AT. Anesthesia was evaluated in terms of success rate, duration of action, and injection pain. These parameters were assessed at the first incisor, premolar, and molar, 60 min after injection. Chi-square and unpaired t-tests were used for statistical comparisons, with a P value of < 0.05 designating significance. The two nerve block techniques generated comparable success rates for the right mandible, with rates of 65% (CT) and 60% (AT) at both the first molar and premolar, and rates of 60% (CT) and 50% (AT) at the lateral incisor. The duration of anesthesia using the CT was 233 ± 37 min, which was approximately 40 min shorter than using the AT. This difference was statistically significant (P < 0.05). Injection pain using the AT was rated as milder compared with the CT. This difference was also statistically significant (P < 0.05). The AT is no less successful than the CT for inducing anesthesia, and has the added benefits of a significantly longer duration of action and significantly less pain.
Laser-activated solid protein bands for peripheral nerve repair: an vivo study.
Lauto, A; Trickett, R; Malik, R; Dawes, J M; Owen, E R
1997-01-01
Severed tibial nerves in rats were repaired using a novel technique, utilizing a semiconductor diode-laser-activated protein solder applied longitudinally across the join. Welding was produced by selective laser denaturation of solid solder bands containing the dye indocyanine green. An in vivo study, using 48 adult male Wistar rats, compared conventional microsuture-repaired tibial nerves with laser solder-repaired nerves. Nerve repairs were characterised immediately after surgery and after 3 months. Successful regeneration with average compound muscle action potentials of 2.5 +/- 0.5 mV and 2.7 +/- 0.3 mV (mean and standard deviation) was demonstrated for the laser-soldered nerves and the sutured nerves, respectively. Histopathology confirmed comparable regeneration of axons in laser- and suture-operated nerves. The laser-based nerve repair technique was easier and faster than microsuture repair, minimising manipulation damage to the nerve.
Electrophysiology of Cranial Nerve Testing: Spinal Accessory and Hypoglossal Nerves.
Stino, Amro M; Smith, Benn E
2018-01-01
Multiple techniques have been developed for the electrodiagnostic evaluation of cranial nerves XI and XII. Each of these carries both benefits and limitations, with more techniques and data being available in the literature for spinal accessory than hypoglossal nerve evaluation. Spinal accessory and hypoglossal neuropathy are relatively uncommon cranial mononeuropathies that may be evaluated in the outpatient electrodiagnostic laboratory setting. A review of available literature using PubMed was conducted regarding electrodiagnostic technique in the evaluation of spinal accessory and hypoglossal nerves searching for both routine nerve conduction studies and repetitive nerve conduction studies. The review provided herein provides a resource by which clinical neurophysiologists may develop and implement clinical and research protocols for the evaluation of both of these lower cranial nerves in the outpatient setting.
Kung, Theodore A; Langhals, Nicholas B; Martin, David C; Johnson, Philip J; Cederna, Paul S; Urbanchek, Melanie G
2014-06-01
The regenerative peripheral nerve interface is an internal interface for signal transduction with external electronics of prosthetic limbs; it consists of an electrode and a unit of free muscle that is neurotized by a transected residual peripheral nerve. Adding a conductive polymer coating on electrodes improves electrode conductivity. This study examines regenerative peripheral nerve interface tissue viability and signal fidelity in the presence of an implanted electrode coated or uncoated with a conductive polymer. In a rat model, the extensor digitorum longus muscle was moved as a nonvascularized free tissue transfer and neurotized by the divided peroneal nerve. Either a stainless steel pad electrode (n = 8) or a pad electrode coated with poly(3,4-ethylenedioxythiophene) conductive polymer (PEDOT) (n = 8) was implanted on the muscle transfer and secured with an encircling acellular extracellular matrix. The contralateral muscle served as the control. The free muscle transfers were successfully revascularized and over time reinnervated as evidenced by serial insertional needle electromyography. Compound muscle action potentials were successfully transduced through the regenerative peripheral nerve interface. The conductive polymer coating on the implanted electrode resulted in increased recorded signal amplitude that was observed throughout the course of the study. Histologic examination confirmed axonal sprouting, elongation, and synaptogenesis within regenerative peripheral nerve interface regardless of electrode type. The regenerative peripheral nerve interface remains viable over seven months in the presence of an implanted electrode. Electrodes with and without conductive polymer reliably transduced signals from the regenerative peripheral nerve interface. Electrodes with a conductive polymer coating resulted in recording more of the regenerative peripheral nerve interface signal.
Large Extremity Peripheral Nerve Repair
2014-10-01
nerve allotransplantation in rats immunosuppressed with transient or long-term FK-506. Journal of reconstructive microsurgery . 1996 Oct;12(7):451-9...outcomes in sensory, mixed, and motor nerve reconstructions . Microsurgery . 2012 Jan;32(1):1-14. PubMed PMID: 22121093. Epub 2011/11/29. eng. 12...method can provide fixation strengths 5 approaching that of conventional microsurgery and that the PTB repair is unlikely to be disturbed in vivo
Effect of hip and knee position on nerve conduction in the common fibular nerve.
Broadhurst, Peter Kaas; Robinson, Lawrence R
2017-09-01
The aim of this study was to measure the influence that hip and knee position have on routine fibular motor nerve conduction studies. Healthy subjects under age 40 were recruited (n = 24) to have fibular nerve conduction studies completed in various positions, using hip extension-knee extension as a control. A mean increase in conduction velocity of 2.5 m/s across the knee (P = 0.020) was seen during hip flexion compared with hip extension. A mean decrease in velocity of 1.6 m/s through the leg segment (P = 0.016) was seen during knee flexion compared with knee extension. This study shows that the optimal position of the leg during fibular nerve studies is with the hip in flexion and knee in extension, to more accurately reflect nerve length for velocity calculations. This may have implications for other peripheral nerves with respect to proximal joint position affecting calculated velocity. Muscle Nerve 56: 519-521, 2017. © 2017 Wiley Periodicals, Inc.
Sensory conduction of the sural nerve in polyneuropathy.
Burke, D; Skuse, N F; Lethlean, A K
1974-06-01
Using surface electrodes, sensory nerve action potentials (SAP) have been recorded in the proximal segment (mid-calf to lateral malleolus) and the distal segment (lateral malleolus to toe 5) of the sural nerve and in the median nerve in 79 control subjects. The values obtained for the distal segment of the sural nerve varied widely and in seven apparently normal subjects no SAP could be distinguished. In the proximal segment conduction velocities were over 40 m/s and there was no significant change with age, unlike the median nerve in which a highly significant slowing occurred with age. Comparison of the results of sural and median sensory conduction studies in 300 consecutive patients screened for sensory polyneuropathy confirms the value of sural nerve sensory studies as a routine screening test, and confirms the belief that the changes in polyneuropathy are usually more prominent in lower limb nerves. It is therefore suggested that studies of sural sensory conduction form the single most useful test in the diagnosis of sensory polyneuropathy.
Effect of Limb Lengthening on Internodal Length and Conduction Velocity of Peripheral Nerve
Gillingwater, Thomas H.; Anderson, Heather; Cottrell, David; Sherman, Diane L.; Ribchester, Richard R.; Brophy, Peter J.
2013-01-01
The influences of axon diameter, myelin thickness, and internodal length on the velocity of conduction of peripheral nerve action potentials are unclear. Previous studies have demonstrated a strong dependence of conduction velocity on internodal length. However, a theoretical analysis has suggested that this relationship may be lost above a nodal separation of ∼0.6 mm. Here we measured nerve conduction velocities in a rabbit model of limb lengthening that produced compensatory increases in peripheral nerve growth. Divided tibial bones in one hindlimb were gradually lengthened at 0.7 mm per day using an external frame attached to the bone. This was associated with a significant increase (33%) of internodal length (0.95–1.3 mm) in axons of the tibial nerve that varied in proportion to the mechanical strain in the nerve of the lengthened limb. Axonal diameter, myelin thickness, and g-ratios were not significantly altered by limb lengthening. Despite the substantial increase in internodal length, no significant change was detected in conduction velocity (∼43 m/s) measured either in vivo or in isolated tibial nerves. The results demonstrate that the internode remains plastic in the adult but that increases in internodal length of myelinated adult nerve axons do not result in either deficiency or proportionate increases in their conduction velocity and support the view that the internodal lengths of nerves reach a plateau beyond which their conduction velocities are no longer sensitive to increases in internodal length. PMID:23467369
Selective reinnervation: a comparison of recovery following microsuture and conduit nerve repair.
Evans, P J; Bain, J R; Mackinnon, S E; Makino, A P; Hunter, D A
1991-09-20
Selective reinnervation was studied by comparing the regeneration across a conventional neurorraphy versus a conduit nerve repair. Lewis rats underwent right sciatic nerve transection followed by one of four different nerve repairs (n = 8/group). In groups I and II a conventional neurorraphy was performed and in groups III and IV the proximal and distal stumps were coapted by use of a silicone conduit with an interstump gap of 5 mm. The proximal and distal stumps in groups I and III were aligned anatomically correct and the proximal stump was rotated 180 degrees in groups II and IV (i.e. proximal peroneal nerve opposite the distal tibial nerve and the proximal tibial nerve opposite the distal peroneal nerve). By 14 weeks, there was an equivalent, but incomplete return in sciatic function index (SFI) in groups I, III, and IV as measured by walking track analysis. However, the SFI became unmeasurable by 6 weeks in all group II animals. At 14 weeks, the percent innervation of the tibialis anterior and medial gastronemius muscles by the peroneal and tibial nerves respectively was estimated by selective compound muscle action potential amplitude recordings. When fascicular alignment was reversed, there was greater tibial (P = 0.02) and lesser peroneal (P = 0.005) innervation of the gastrocnemius muscle in the conduit (group IV) versus the neurorraphy (group II) group. This suggests that the gastrocnemius muscle may be selectively reinnervated by the tibial nerve. However, there was no evidence of selective reinnervation of the tibialis anterior muscle. Despite these differences, the functional recovery in both conduit repair groups (III and IV) was equivalent to a correctly aligned microsuture repair (group I) and superior to that in the incorrectly aligned microsuture repair (group II).
Suzuki, K; Yen-Chung, H; Toyota, T; Goto, Y; Hirata, Y; Okada, K
1990-05-01
This study was carried out to clarify the relationship between the slowing of motor nerve conduction velocity and nerve levels of sorbitol, fructose, glucose and myoinositol in spontaneously diabetic GK (Goto-Kakizaki) rats. The motor nerve conduction velocity in GK rats was constantly lower than in normal controls at three and nine months of age. This constant decrease in motor nerve conduction velocity in GK rats was closely related to glucose intolerance in GK rats soon after birth. Nerve levels of sorbitol, glucose and fructose in GK rats were significantly increased as compared to normal controls at nine months old, but not (except glucose) at three months old. The increase in nerve concentrations of sugars in GK rats was progressive with age. However, levels of glucose, sorbitol and fructose in normal Wistar rats remain unchanged with age. Although nerve myo-inositol levels in GK rats were lower at three and nine months than those of normal controls, a significant difference in myo-inositol levels was observed only at nine months. On the contrary, nerve myo-inositol level in normal Wistar rats did not show age-related change. These findings suggested that both enhanced polyol pathway activity and myo-inositol depletion play important roles in the reduction of motor nerve conduction velocity.
Magazzeni, Philippe; Jochum, Denis; Iohom, Gabriella; Mekler, Gérard; Albuisson, Eliane; Bouaziz, Hervé
2018-06-13
For superficial surgery of anteromedial and posteromedial surfaces of the upper arm, the medial brachial cutaneous nerve (MBCN) and the intercostobrachial nerve (ICBN) must be selectively blocked, in addition to an axillary brachial plexus block. We compared efficacy of ultrasound-guided (USG) versus conventional block of the MBCN and the ICBN. Eighty-four patients, undergoing upper limb surgery, were randomized to receive either USG (n = 42) or conventional (n = 42) block of the MBCN and the ICBN with 1% mepivacaine. Sensory block was evaluated using light-touch on the upper and lower half of the anteromedial and posteromedial surfaces of the upper arm at 5, 10, 15, 20 minutes after nerve blocks. The primary outcome was the proportion of patients who had no sensation in all 4 regions innervated by the MBCN and the ICBN at 20 minutes. Secondary outcomes were onset time of complete anesthesia, volume of local anesthetic, tourniquet tolerance, and quality of ultrasound images. In the USG group, 37 patients (88%) had no sensation at 20 minutes in any of the 4 areas tested versus 8 patients (19%) in the conventional group (P < 0.001). When complete anesthesia was obtained, it occurred within 10 minutes in more than 90% of patients, in both groups. Mean total volumes of local anesthetic used for blocking the MBCN and the ICBN were similar in the 2 groups. Ultrasound images were of good quality in only 20 (47.6%) of 42 patients. Forty-one patients (97.6%) who received USG block were comfortable with the tourniquet versus 16 patients (38.1%) in the conventional group (P < 0.001). Ultrasound guidance improved the efficacy of the MBCN and ICBN blocks. This study was registered at ClinicalTrials.gov, identifier NCT02940847.
Nerve-muscle activation by rotating permanent magnet configurations.
Watterson, Peter A; Nicholson, Graham M
2016-04-01
The standard method of magnetic nerve activation using pulses of high current in coils has drawbacks of high cost, high electrical power (of order 1 kW), and limited repetition rate without liquid cooling. Here we report a new technique for nerve activation using high speed rotation of permanent magnet configurations, generating a sustained sinusoidal electric field using very low power (of order 10 W). A high ratio of the electric field gradient divided by frequency is shown to be the key indicator for nerve activation at high frequencies. Activation of the cane toad sciatic nerve and attached gastrocnemius muscle was observed at frequencies as low as 180 Hz for activation of the muscle directly and 230 Hz for curved nerves, but probably not in straight sections of nerve. These results, employing the first prototype device, suggest the opportunity for a new class of small low-cost magnetic nerve and/or muscle stimulators. Conventional pulsed current systems for magnetic neurostimulation are large and expensive and have limited repetition rate because of overheating. Here we report a new technique for nerve activation, namely high-speed rotation of a configuration of permanent magnets. Analytical solutions of the cable equation are derived for the oscillating electric field generated, which has amplitude proportional to the rotation speed. The prototype device built comprised a configuration of two cylindrical magnets with antiparallel magnetisations, made to rotate by interaction between the magnets' own magnetic field and three-phase currents in coils mounted on one side of the device. The electric field in a rectangular bath placed on top of the device was both numerically evaluated and measured. The ratio of the electric field gradient on frequency was approximately 1 V m(-2) Hz(-1) near the device. An exploratory series of physiological tests was conducted on the sciatic nerve and attached gastrocnemius muscle of the cane toad (Bufo marinus). Activation was readily observed of the muscle directly, at frequencies as low as 180 Hz, and of nerves bent around insulators, at frequencies as low as 230 Hz. Nerve-muscles, with the muscle elevated to avoid its direct activation, were occasionally activated, possibly in the straight section of the nerve, but more likely in the nerve where it curved up to the muscle, at radius of curvature 10 mm or more, or at the nerve end. These positive first results suggest the opportunity for a new class of small, low-cost devices for magnetic stimulation of nerves and/or muscles. © 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.
NASA Technical Reports Server (NTRS)
Lai, K. S.; Jaweed, M. M.; Seestead, R.; Herbison, G. J.; Ditunno, J. F. Jr; McCully, K.; Chance, B.
1992-01-01
The purpose of this investigation was to study the changes in nerve conduction and phosphate metabolites of the gastrocsoleus muscles of rats during denervation-reinnervation. Sixteen male Sprague-Dawley rats underwent unilateral crush-denervation of the left sciatic nerves at the sciatic notch. Six rats were used for measurement of motor conduction latency and action potential amplitude of the gastrocsoleus muscle by stimulating the sciatic nerve at one, two and eight weeks after nerve crush. The other ten rats were designated for evaluation of the ratio of inorganic phosphorous (Pi) to phosphocreatine (PCr) by a 31P-phosphoenergetic spectrometer at two weeks and eight weeks after nerve crush. None of the sciatic nerves showed conduction to the gastrocsoleus at one or two weeks after nerve crush. At eight weeks postcrush, the motor conduction latency returned to within normal limits, whereas the action potential amplitude was only 55% of the normal. For the eight-week period of study, the Pi/PCr ratio of the normal control muscles ranged between 0.09 +/- 0.02 and 0.11 +/- 0.02 (mean +/- SD). The denervated muscles showed an increase of Pi/PCr ratio by 54% at two weeks postcrush, compared to the respective contralateral control sides. The ratios returned to the normal value by eight weeks postcrush. In summary, these data suggested that the metabolic recovery of the crush-denervated muscle followed the same pattern as the parameters of nerve conduction.
[RESEARCH PROGRESS OF PERIPHERAL NERVE SURGERY ASSISTED BY Da Vinci ROBOTIC SYSTEM].
Shen, Jie; Song, Diyu; Wang, Xiaoyu; Wang, Changjiang; Zhang, Shuming
2016-02-01
To summarize the research progress of peripheral nerve surgery assisted by Da Vinci robotic system. The recent domestic and international articles about peripheral nerve surgery assisted by Da Vinci robotic system were reviewed and summarized. Compared with conventional microsurgery, peripheral nerve surgery assisted by Da Vinci robotic system has distinctive advantages, such as elimination of physiological tremors and three-dimensional high-resolution vision. It is possible to perform robot assisted limb nerve surgery using either the traditional brachial plexus approach or the mini-invasive approach. The development of Da Vinci robotic system has revealed new perspectives in peripheral nerve surgery. But it has still been at the initial stage, more basic and clinical researches are still needed.
Lee, Hyoung Shin; Lee, Dongwon; Koo, Yong Cheol; Shin, Hyang Ae; Koh, Yoon Woo; Choi, Eun Chang
2013-03-01
In this study, the authors introduce and evaluate the feasibility of endoscopic resection using the retroauricular approach for various benign lesions of the upper neck. A retrospective comparative analysis was performed on the clinical outcomes of patients who underwent surgery for upper neck masses as endoscopic resection using the retroauricular approach or conventional transcervical resection at the authors' center from January 2010 through August 2011. The primary outcome was the cosmetic satisfaction of the patients in each group. In addition, the feasibility of the procedure was evaluated by comparing the operation time; hospital stay; amount and duration of drainage; complications such as marginal mandibular nerve, lingual, or hypoglossal nerve palsy; paresthesia of the ear lobe; and wound problems such as hematoma and skin necrosis. Statistical analysis was performed by independent-samples t test and the Fisher exact test, and a P value less than .05 was considered statistically significant. Thirty-six patients underwent endoscopic resection (endo group; 15 men, 21 women; mean age, 38.8 ± 15.0 years) and 40 patients underwent conventional transcervical resection (conventional group; 18 men, 22 women; mean age, 45.1 ± 14.1 years). The operating time in the endo group was longer than in the conventional group (P = .003). No significant difference was observed in the overall perioperative complications between the 2 groups. Cosmetic satisfaction evaluated with a graded scale showed much better results in the endo group (P < .001). Endoscopic resection using the retroauricular approach is feasible for various benign upper neck masses when conducted by an experienced endoscopic surgeon, with excellent cosmetic results. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Raman spectroscopic detection of peripheral nerves towards nerve-sparing surgery
NASA Astrophysics Data System (ADS)
Minamikawa, Takeo; Harada, Yoshinori; Takamatsu, Tetsuro
2017-02-01
The peripheral nervous system plays an important role in motility, sensory, and autonomic functions of the human body. Preservation of peripheral nerves in surgery, namely nerve-sparing surgery, is now promising technique to avoid functional deficits of the limbs and organs following surgery as an aspect of the improvement of quality of life of patients. Detection of peripheral nerves including myelinated and unmyelinated nerves is required for the nerve-sparing surgery; however, conventional nerve identification scheme is sometimes difficult to identify peripheral nerves due to similarity of shape and color to non-nerve tissues or its limited application to only motor peripheral nerves. To overcome these issues, we proposed a label-free detection technique of peripheral nerves by means of Raman spectroscopy. We found several fingerprints of peripheral myelinated and unmyelinated nerves by employing a modified principal component analysis of typical spectra including myelinated nerve, unmyelinated nerve, and adjacent tissues. We finally realized the sensitivity of 94.2% and the selectivity of 92.0% for peripheral nerves including myelinated and unmyelinated nerves against adjacent tissues. Although further development of an intraoperative Raman spectroscopy system is required for clinical use, our proposed approach will serve as a unique and powerful tool for peripheral nerve detection for nerve-sparing surgery in the future.
Sciatic Nerve Conductivity is Impaired by Hamstring Strain Injuries.
Kouzaki, Karina; Nakazato, Koichi; Mizuno, Masuhiko; Yonechi, Tooru; Higo, Yusuke; Kubo, Yoshiaki; Kono, Tokuyoshi; Hiranuma, Kenji
2017-10-01
The aim of this study was to assess sciatic nerve conductivity in athletes with a history of hamstring strain injuries. Twenty-seven athletes with a history of hamstring strain injuries were included in the injured group. The control group consisted of 16 uninjured participants. We measured the proximal and distal latencies and calculated the sciatic nerve conduction velocity to evaluate neuronal conductivity. The results were expressed as median values and interquartile ranges. Both proximal latency and distal latency of the injured limb in the injured group were significantly longer than those of the uninjured limb (p<0.05). The nerve conduction velocity of the injured limb in the injured group was significantly lower than that of the uninjured limb (p<0.05). There were no significant side-to-side differences in the control group. Sciatic nerve conductivity impairments may exist in athletes with a history of hamstring strain injuries. © Georg Thieme Verlag KG Stuttgart · New York.
Nerve cuff electrode using embedded magnets and its application to hypoglossal nerve stimulation.
Seo, Jungmin; Wee, Jee Hye; Park, Jeong Hoan; Park, Pona; Kim, Jeong-Whun; Kim, Sung June
2016-12-01
A novel nerve cuff electrode with embedded magnets was fabricated and developed. In this study, a pair of magnets was fully embedded and encapsulated in a liquid crystal polymer (LCP) substrate to utilize magnetic force in order to replace the conventional installing techniques of cuff electrodes. In vitro and in vivo experiments were conducted to evaluate the feasibility of the magnet-embedded nerve cuff electrode (MENCE). Lastly, several issues pertaining to the MENCE such as the cuff-to-nerve diameter ratio, the force of the magnets, and possible concerns were discussed in the discussion section. Electrochemical impedance spectrum and cyclic voltammetry assessments were conducted to measure the impedance and charge storage capacity of the cathodal phase (CSC c ). The MENCE was installed onto the hypoglossal nerve (HN) of a rabbit and the movement of the genioglossus was recorded through C-arm fluoroscopy while the HN was stimulated by a pulsed current. The measured impedance was 0.638 ∠ -67.8° kΩ at 1 kHz and 5.27 ∠ -82.1° kΩ at 100 Hz. The average values of access resistance and cut-off frequency were 0.145 kΩ and 3.98 kHz, respectively. The CSC c of the electrode was measured as 1.69 mC cm -2 at the scan rate of 1 mV s -1 . The movement of the genioglossus contraction was observed under a pulsed current with an amplitude level of 0.106 mA, a rate of 0.635 kHz, and a duration of 0.375 ms applied through the MENCE. A few methods to close and secure cuff electrodes have been researched, but they are associated with several drawbacks. To overcome these, we used magnetic force as a closing method of the cuff electrode. The MENCE can be precisely installed on a target nerve without any surgical techniques such as suturing or molding. Furthermore, it is convenient to remove the installed MENCE because it requires little force to detach one magnet from the other, enabling repeatable installation and removal. We anticipate that the MENCE will become a very useful tool given its unique properties as a cuff electrode for neural engineering.
El-Tantawi, Gihan A Younis; Imam, Mohamed H; Morsi, Tamer S
2015-01-01
Diaphragmatic weakness in chronic obstructive pulmonary disease (COPD) is ascribed to hyperinflation-induced diaphragm shortening as well as impairment in cellular and subcellular structures. Although phrenic neuropathy is known to cause diaphragmatic weakness, phrenic neuropathy is rarely considered in COPD. This work aimed at assessing phrenic nerve conduction in COPD and its relation to radiographic hyperinflation and pulmonary function. Forty COPD patients were evaluated. Radiographic parameters of lung hyperinflation were measured on postero-anterior and lateral chest x-ray films. Flow volume loop parameters were obtained from all patients. Motor conduction study of the phrenic nerves was performed and potentials were recorded over the xiphoid process and the ipsilateral 7th intercostal space. Twenty-seven healthy subjects were enrolled as controls. Parameters of phrenic nerve conduction differed significantly in patients compared to controls. Phrenic nerve abnormalities were detected in 17 patients (42.5%). Electrophysiological measures correlated with diaphragmatic angle of depression on lateral view films and with lung height on postero-anterior films. They did not correlate with the flow volume loop data or disease severity score. Phrenic nerve conduction abnormality is an appreciated finding in COPD. Nerve stretching associated with diaphragmatic descent can be a suggested mechanism for nerve lesion. The presence of phrenic neuropathy may be an additional contributing factor to diaphragmatic dysfunction in COPD patients.
Caccia, M R; Dezuanni, E; Salvaggio, A; Osio, M; Bevilacqua, M; Norbiato, G; Mangoni, A
1991-01-01
Conventional motor (MCV) and sensory conduction velocity (SCV) of the ulnar (UN), peroneal (PN) and median nerves (MN) and the areas of sympathetic sudomotor response (SSR) recorded from the middle finger were measured on both sides in 20 normal and 20 non-insulin-dependent diabetic (NIDD) subjects. Conventional statistical tests (t test, linear correlation coefficient r) and discrimination analysis were applied to the above electrophysiological parameters. To evaluate the capability of the tests to separate NIDD diseased from normal nerves, the results were represented as generalized distances, i.e., difference between mean discriminant normalized combinations adjusted for intra-group variability. The r values were 0.92 (P less than 0.01) for the UN, 0.40 (P greater than 0.05) for the PN, and 0.86 (P less than 0.01) for the MN sensory action potential (SAP) amplitudes. No significant differences were found for normalized latencies. The r values of the SSR areas were 0.62 (P less than 0.01) at the right and 0.77 (P less than 0.01) at the left, homolaterally to the side of stimulation. SR and MCV generalized distances were 1.35 and 1.39, respectively. The discriminating power of SSR, MCV and SCV considered together was higher (2.40) than that of MCV and SCV (1.70). Since motor, sensory and autonomic alterations often did not coexist in NIDD, it was possible to find at least one type of involvement in most of the diabetic subjects.
Reversible median nerve impairment after three weeks of repetitive work.
Tabatabaeifar, Sorosh; Svendsen, Susanne Wulff; Johnsen, Birger; Hansson, Gert-Åke; Fuglsang-Frederiksen, Anders; Frost, Poul
2017-03-01
Objectives The aim of this study was to evaluate the development of impaired median nerve function in relation to hand-intensive seasonal work. We hypothesized that at end-season, median nerve conduction would be impaired and then recover within weeks. Methods Using nerve conduction studies (NCS), we examined median nerve conduction before, during, and after engaging in 22 days of mink skinning. For a subgroup, we used goniometry and surface electromyography to characterize occupational mechanical exposures. Questionnaire information on symptoms, disability, and lifestyle factors was obtained. Results The study comprised 11 male mink skinners with normal median nerve conduction at pre-season (mean age 35.7 years, mean number of seasons with skinning 8.9 years). Mink skinning was characterized by a median angle of wrist flexion/extension of 16º extension, a median velocity of wrist flexion/extension of 22 °/s, and force exertions of 11% of maximal voluntary electrical activity. At end-season, mean distal motor latency (DML) had increased 0.41 ms (P<0.001), mean sensory nerve conduction velocity (SNCV) digit 2 had decreased 6.3 m/s (P=0.004), and mean SNCV digit 3 had decreased 6.2 m/s (P=0.01); 9 mink skinners had decreases in nerve conduction, 5 fulfilled electrodiagnostic criteria and 4 fulfilled electrodiagnostic and clinical criteria (a positive Katz hand diagram) for carpal tunnel syndrome (CTS). Three to six weeks post-season, the changes had reverted to normal. Symptom and disability scores showed corresponding changes. Conclusions In this natural experiment, impaired median nerve conduction developed during 22 days of repetitive industrial work with moderate wrist postures and limited force exertion. Recovery occurred within 3-6 weeks post-season.
Shi, Yin; Zong, Min; Xu, Xiaoquan; Zou, Yuefen; Feng, Yang; Liu, Wei; Wang, Chuanbing; Wang, Dehang
2015-04-01
To quantitatively evaluate nerve roots by measuring fractional anisotropy (FA) values in healthy volunteers and sciatica patients, visualize nerve roots by tractography, and compare the diagnostic efficacy between conventional magnetic resonance imaging (MRI) and DTI. Seventy-five sciatica patients and thirty-six healthy volunteers underwent MR imaging using DTI. FA values for L5-S1 lumbar nerve roots were calculated at three levels from DTI images. Tractography was performed on L3-S1 nerve roots. ROC analysis was performed for FA values. The lumbar nerve roots were visualized and FA values were calculated in all subjects. FA values decreased in compressed nerve roots and declined from proximal to distal along the compressed nerve tracts. Mean FA values were more sensitive and specific than MR imaging for differentiating compressed nerve roots, especially in the far lateral zone at distal nerves. DTI can quantitatively evaluate compressed nerve roots, and DTT enables visualization of abnormal nerve tracts, providing vivid anatomic information and localization of probable nerve compression. DTI has great potential utility for evaluating lumbar nerve compression in sciatica. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Intraoperative nerve monitoring in laryngotracheal surgery.
Bolufer, Sergio; Coves, María Dolores; Gálvez, Carlos; Villalona, Gustavo Adolfo
Laryngotracheal surgery has an inherent risk of injury to the recurrent laryngeal nerves (RLN). These complications go from minor dysphonia to even bilateral vocal cord paralysis. The intraoperative neuromonitoring of the RLN was developed in the field of thyroid surgery, in order to preserve nerve and vocal cord function. However, tracheal surgery requires in-field intubation of the distal trachea, which limits the use of nerve monitoring using conventional endotracheal tube with surface electrodes. Given these challenges, we present an alternative method for nerve monitoring during laryngotracheal surgery through the insertion of electrodes within the endolaryngeal musculature by bilateral puncture. Copyright © 2016 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Nerve–muscle activation by rotating permanent magnet configurations
Nicholson, Graham M.
2016-01-01
Key points The standard method of magnetic nerve activation using pulses of high current in coils has drawbacks of high cost, high electrical power (of order 1 kW), and limited repetition rate without liquid cooling.Here we report a new technique for nerve activation using high speed rotation of permanent magnet configurations, generating a sustained sinusoidal electric field using very low power (of order 10 W).A high ratio of the electric field gradient divided by frequency is shown to be the key indicator for nerve activation at high frequencies.Activation of the cane toad sciatic nerve and attached gastrocnemius muscle was observed at frequencies as low as 180 Hz for activation of the muscle directly and 230 Hz for curved nerves, but probably not in straight sections of nerve.These results, employing the first prototype device, suggest the opportunity for a new class of small low‐cost magnetic nerve and/or muscle stimulators. Abstract Conventional pulsed current systems for magnetic neurostimulation are large and expensive and have limited repetition rate because of overheating. Here we report a new technique for nerve activation, namely high‐speed rotation of a configuration of permanent magnets. Analytical solutions of the cable equation are derived for the oscillating electric field generated, which has amplitude proportional to the rotation speed. The prototype device built comprised a configuration of two cylindrical magnets with antiparallel magnetisations, made to rotate by interaction between the magnets’ own magnetic field and three‐phase currents in coils mounted on one side of the device. The electric field in a rectangular bath placed on top of the device was both numerically evaluated and measured. The ratio of the electric field gradient on frequency was approximately 1 V m−2 Hz−1 near the device. An exploratory series of physiological tests was conducted on the sciatic nerve and attached gastrocnemius muscle of the cane toad (Bufo marinus). Activation was readily observed of the muscle directly, at frequencies as low as 180 Hz, and of nerves bent around insulators, at frequencies as low as 230 Hz. Nerve–muscles, with the muscle elevated to avoid its direct activation, were occasionally activated, possibly in the straight section of the nerve, but more likely in the nerve where it curved up to the muscle, at radius of curvature 10 mm or more, or at the nerve end. These positive first results suggest the opportunity for a new class of small, low‐cost devices for magnetic stimulation of nerves and/or muscles. PMID:26661902
Nerve ultrasound shows subclinical peripheral nerve involvement in neurofibromatosis type 2.
Telleman, Johan A; Stellingwerff, Menno D; Brekelmans, Geert J; Visser, Leo H
2018-02-01
Neurofibromatosis type 2 (NF2) is mainly associated with central nervous system (CNS) tumors. Peripheral nerve involvement is described in symptomatic patients, but evidence of subclinical peripheral nerve involvement is scarce. We conducted a cross-sectional pilot study in 2 asymptomatic and 3 minimally symptomatic patients with NF2 to detect subclinical peripheral nerve involvement. Patients underwent clinical examination, nerve conduction studies (NCS), and high-resolution ultrasonography (HRUS). A total of 30 schwannomas were found, divided over 20 nerve segments (33.9% of all investigated nerve segments). All patients had at least 1 schwannoma. Schwannomas were identified with HRUS in 37% of clinically unaffected nerve segments and 50% of nerve segments with normal NCS findings. HRUS shows frequent subclinical peripheral nerve involvement in NF2. Clinicians should consider peripheral nerve involvement as a cause of weakness and sensory loss in the extremities in patients with this disease. Muscle Nerve 57: 312-316, 2018. © 2017 Wiley Periodicals, Inc.
Recovery from distal ulnar motor conduction block injury: serial EMG studies.
Montoya, Liliana; Felice, Kevin J
2002-07-01
Acute conduction block injuries often result from nerve compression or trauma. The temporal pattern of clinical, electrophysiologic, and histopathologic changes following these injuries has been extensively studied in experimental animal models but not in humans. Our recent evaluation of a young man with an injury to the deep motor branch of the ulnar nerve following nerve compression from weightlifting exercises provided the opportunity to follow the course and recovery of a severe conduction block injury with sequential nerve conduction studies. The conduction block slowly and completely resolved, as did the clinical deficit, over a 14-week period. The reduction in conduction block occurred at a linear rate of -6.1% per week. Copyright 2002 Wiley Periodicals, Inc.
Balasubramanian, Sasikala; Paneerselvam, Elavenil; Guruprasad, T; Pathumai, M; Abraham, Simin; Krishnakumar Raja, V B
2017-01-01
The aim of this randomized clinical trial was to assess the efficacy of exclusive lingual nerve block (LNB) in achieving selective lingual soft-tissue anesthesia in comparison with conventional inferior alveolar nerve block (IANB). A total of 200 patients indicated for the extraction of lower premolars were recruited for the study. The samples were allocated by randomization into control and study groups. Lingual soft-tissue anesthesia was achieved by IANB and exclusive LNB in the control and study group, respectively. The primary outcome variable studied was anesthesia of ipsilateral lingual mucoperiosteum, floor of mouth and tongue. The secondary variables assessed were (1) taste sensation immediately following administration of local anesthesia and (2) mouth opening and lingual nerve paresthesia on the first postoperative day. Data analysis for descriptive and inferential statistics was performed using SPSS (IBM SPSS Statistics for Windows, Version 22.0, Armonk, NY: IBM Corp. Released 2013) and a P < 0.05 was considered statistically significant. In comparison with the control group, the study group (LNB) showed statistically significant anesthesia of the lingual gingiva of incisors, molars, anterior floor of the mouth, and anterior tongue. Exclusive LNB is superior to IAN nerve block in achieving selective anesthesia of lingual soft tissues. It is technically simple and associated with minimal complications as compared to IAN block.
Balasubramanian, Sasikala; Paneerselvam, Elavenil; Guruprasad, T; Pathumai, M; Abraham, Simin; Krishnakumar Raja, V. B.
2017-01-01
Objective: The aim of this randomized clinical trial was to assess the efficacy of exclusive lingual nerve block (LNB) in achieving selective lingual soft-tissue anesthesia in comparison with conventional inferior alveolar nerve block (IANB). Materials and Methods: A total of 200 patients indicated for the extraction of lower premolars were recruited for the study. The samples were allocated by randomization into control and study groups. Lingual soft-tissue anesthesia was achieved by IANB and exclusive LNB in the control and study group, respectively. The primary outcome variable studied was anesthesia of ipsilateral lingual mucoperiosteum, floor of mouth and tongue. The secondary variables assessed were (1) taste sensation immediately following administration of local anesthesia and (2) mouth opening and lingual nerve paresthesia on the first postoperative day. Results: Data analysis for descriptive and inferential statistics was performed using SPSS (IBM SPSS Statistics for Windows, Version 22.0, Armonk, NY: IBM Corp. Released 2013) and a P < 0.05 was considered statistically significant. In comparison with the control group, the study group (LNB) showed statistically significant anesthesia of the lingual gingiva of incisors, molars, anterior floor of the mouth, and anterior tongue. Conclusion: Exclusive LNB is superior to IAN nerve block in achieving selective anesthesia of lingual soft tissues. It is technically simple and associated with minimal complications as compared to IAN block. PMID:29264294
Landegren, Thomas; Risling, Mårten; Hammarberg, Henrik; Persson, Jonas K. E.
2011-01-01
There is a need for complementary surgical techniques that enable rapid and reliable primary repair of transected nerves. Previous studies after peripheral nerve transection and repair with synthetic adhesives have demonstrated regeneration to an extent comparable to that of conventional techniques. The aim of this study was to compare two different repair techniques on the selectivity of muscle reinnervation after repair and completed regeneration. We used the cholera toxin B technique of retrograde axonal tracing to evaluate the morphology, the number, and the three-dimensional location of α-motoneurons innervating the lateral gastrocnemius muscle and compared the results after repair with either ethyl cyanoacrylate (ECA) or epineural sutures of the transected parent sciatic nerve. In addition, we recorded the wet weight of the muscle. Six months after transection and repair of the sciatic nerve, the redistribution of the motoneuron pool was markedly disorganized, the motoneurons had apparently increased in number, and they were scattered throughout a larger volume of the spinal cord gray matter with a decrease in the synaptic coverage compared to controls. A reduction in muscle weight was observed as well. No difference in morphometric variables or muscle weight between the two repair methods could be detected. We conclude that the selectivity of motor reinnervation following sciatic nerve transection and subsequent repair with ECA is comparable to that following conventional micro suturing. PMID:21577248
Sonography-guided recording for superficial peroneal sensory nerve conduction study.
Kim, Ki Hoon; Park, Byung Kyu; Kim, Dong Hwee; Kim, Yuntae
2018-04-01
We sought to establish the optimal recording position for antidromic conduction of the superficial peroneal nerve (SPN) by using ultrasonography (USG). The sensory nerve action potentials (SNAPs) of the intermediate dorsal cutaneous nerve (IDCN) and medial dorsal cutaneous nerve (MDCN) in 64 limbs of 32 healthy participants were recorded (nerve conduction study [NCS]-1). Both nerves were identified by using USG, and the SNAPs were obtained from the USG-guided repositioned electrodes (NCS-2). The IDCN and MDCN were located at 29.3% ± 5.1% and 43.9% ± 4.9% of the intermalleolar distance from the lateral malleolus, respectively. Significantly greater amplitude was shown for SNAPs of both nerves in NCS-2 versus NCS-1. The optimal recording position is likely to be lateral, one-third from the lateral malleolus for the IDCN, and just lateral to the midpoint of the intermalleolar line for the MDCN. When the SPN response is unexpectedly attenuated, USG-guided repositioning of the electrodes should be considered. Muscle Nerve 57: 628-633, 2018. © 2017 Wiley Periodicals, Inc.
Pagotto, Luis Eduardo Charles; de Santana Santos, Thiago; de Vasconcellos, Sara Juliana de Abreu; Santos, Joanes Silva; Martins-Filho, Paulo Ricardo Saquete
2017-10-01
The purpose of this study was to perform a systematic review and meta-analysis of complications after orthognathic surgery comparing piezo-surgery with conventional osteotomy. We conducted this study according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. We performed a systematic search of PubMed, Scopus, Science Direct, Lilacs, Cochrane Central Register of Controlled Trials, Google Scholar, and OpenThesis to identify randomized and nonrandomized controlled trials (RCTs and nRCTs, respectively) comparing patient outcomes (operative time, intraoperative blood loss, postoperative swelling, pain, neurosensitivity) after orthognathic surgery by piezoelectric or conventional osteotomy. We pooled individual results of continuous and dichotomous outcome data using the mean difference (MD) and risk difference (RD) with the 95% confidence interval, respectively. Three RCTs and five nRCTs were selected. No difference in operative time was observed between piezo-surgery and conventional osteotomies. We found a decrease of intraoperative blood loss with piezo-surgery (MD -128 mL; P < 0.001) and a pooled difference in severe blood loss of 35% (P = 0.008) favouring piezo-surgery. Based on pooled individual results of studies evaluating neurosensitivity by clinical neurosensory testing, our meta-analysis showed a pooled difference in severe nerve disturbance of 25% (P < 0.0001) favouring piezo-surgery. Test for subgroup differences (I2 = 26.6%) indicated that follow-up time may have an effect on neurosensory disturbance. We found differences between piezo-surgery and conventional osteotomy at 3 months (RD 28%; P < 0.001) and 6 months (RD 15%; P = 0.001) after surgery. Meta-analyses for pain and swelling were not performed because of a lack of sufficient studies. Currently available evidence suggests that piezo-surgery has favorable effects on complications associated with orthognathic surgery, including reductions in intraoperative blood loss and severe nerve disturbance. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Zhu, Fan-Fan; Yang, Li-Zhen
2018-06-26
Type 2 diabetes has an underlying pathology with thyroid dysfunction. However, few studies have investigated the association between thyroid hormones and diabetic peripheral neuropathy. Our aim was to evaluate the relationship between thyroid hormones and electrophysiological properties of peripheral nerves in type 2 diabetes. The medical records of 308 patients with type 2 diabetes were enrolled in this study. Subjects stratified by sex were divided into subgroups based on the diagnosis of nerve conduction study. The nerve conduction parameters were separately described with the spectrum of thyroid hormones. Multivariate regression models to analyze the potential links between thyroid hormones and nerve conduction parameters. The serum free triiodine thyronine levels between normal and abnormal nerve conduction groups were statistically different in total (4.55±0.65 vs 4.37±0.63, P<0.05) and female diabetic patients (4.46±0.50 vs 4.14±0.57, P<0.01). Moreover, the summed amplitude and velocity Z score of female and male increased with free triiodine thyronine levels (P<0.05). Sex-specific binary logistic regression models showed that free triiodine thyronine levels were associated with decreased odds of abnormal nerve conduction diagnosis (odds ratio [95%CI]=0.151[0.047-0.186]) and low tertile of summed amplitude Z score (odds ratio [95%CI]=0.283[0.099-0.809]) in female. In total patients, free triiodine thyronine level was negatively associated with odds of abnormal nerve conduction (odds ratio [95%CI]=0.436 [0.226-0.842]), low tertile of summed velocity (odds ratio [95%CI]=0.44[0.226-0.858]) and amplitude (odds ratio [95%CI]=0.436[0.227-0.838) Z score. Serum free triiodine thyronine level is associated with nerve conduction in diabetes. Low free triiodine thyronine may be a potential risk for diabetic peripheral neuropathy. © Georg Thieme Verlag KG Stuttgart · New York.
Combined KHFAC+DC nerve block without onset or reduced nerve conductivity after block
Franke, Manfred; Vrabec, Tina; Wainright, Jesse; Bhadra, Niloy; Bhadra, Narendra; Kilgore, Kevin
2017-01-01
Background Kilohertz Frequency Alternating Current waveforms (KHFAC) have been shown to provide peripheral nerve conductivity block in many acute and chronic animal models. KHFAC nerve block could be used to address multiple disorders caused by neural over-activity, including blocking pain and spasticity. However, one drawback of KHFAC block is a transient activation of nerve fibers during the initiation of the nerve block, called the onset response. The objective of this study is to evaluate the feasibility of using charge balanced direct current (CBDC) waveforms to temporarily block motor nerve conductivity distally to the KHFAC electrodes to mitigate the block onset-response. Methods A total of eight animals were used in this study. A set of four animals were used to assess feasibility and reproducibility of a combined KHFAC+CBDC block. A following randomized study, conducted on a second set of four animals, compared the onset response resulting from KHFAC alone and combined KHFAC+CBDC waveforms. To quantify the onset, peak forces and the force-time integral were measured during KHFAC block initiation. Nerve conductivity was monitored throughout the study by comparing muscle twitch forces evoked by supra-maximal stimulation proximal and distal to the block electrodes. Each animal of the randomized study received at least 300 seconds (range: 318 to 1563s) of cumulative DC to investigate the impact of combined KHFAC+CBDC on nerve viability. Results The peak onset force was reduced significantly from 20.73 N (range: 18.6–26.5 N) with KHFAC alone to 0.45 N (range: 0.2–0.7 N) with the combined CBDC and KHFAC block waveform (p<0.001). The area under the force curve was reduced from 6.8 Ns (range: 3.5–21.9 Ns) to 0.54 Ns (range: 0.18–0.86Ns) (p<0.01). No change in nerve conductivity was observed after application of the combined KHFAC+CBDC block relative to KHFAC waveforms. Conclusion The distal application of CBDC can significantly reduce or even completely prevent the KHFAC onset response without a change in nerve conductivity. PMID:25115572
Combined KHFAC + DC nerve block without onset or reduced nerve conductivity after block
NASA Astrophysics Data System (ADS)
Franke, Manfred; Vrabec, Tina; Wainright, Jesse; Bhadra, Niloy; Bhadra, Narendra; Kilgore, Kevin
2014-10-01
Objective. Kilohertz frequency alternating current (KHFAC) waveforms have been shown to provide peripheral nerve conductivity block in many acute and chronic animal models. KHFAC nerve block could be used to address multiple disorders caused by neural over-activity, including blocking pain and spasticity. However, one drawback of KHFAC block is a transient activation of nerve fibers during the initiation of the nerve block, called the onset response. The objective of this study is to evaluate the feasibility of using charge balanced direct current (CBDC) waveforms to temporarily block motor nerve conductivity distally to the KHFAC electrodes to mitigate the block onset-response. Approach. A total of eight animals were used in this study. A set of four animals were used to assess feasibility and reproducibility of a combined KHFAC + CBDC block. A following randomized study, conducted on a second set of four animals, compared the onset response resulting from KHFAC alone and combined KHFAC + CBDC waveforms. To quantify the onset, peak forces and the force-time integral were measured during KHFAC block initiation. Nerve conductivity was monitored throughout the study by comparing muscle twitch forces evoked by supra-maximal stimulation proximal and distal to the block electrodes. Each animal of the randomized study received at least 300 s (range: 318-1563 s) of cumulative dc to investigate the impact of combined KHFAC + CBDC on nerve viability. Main results. The peak onset force was reduced significantly from 20.73 N (range: 18.6-26.5 N) with KHFAC alone to 0.45 N (range: 0.2-0.7 N) with the combined CBDC and KHFAC block waveform (p < 0.001). The area under the force curve was reduced from 6.8 Ns (range: 3.5-21.9 Ns) to 0.54 Ns (range: 0.18-0.86 Ns) (p < 0.01). No change in nerve conductivity was observed after application of the combined KHFAC + CBDC block relative to KHFAC waveforms. Significance. The distal application of CBDC can significantly reduce or even completely prevent the KHFAC onset response without a change in nerve conductivity.
Comparative Analysis Between Computed and Conventional Inferior Alveolar Nerve Block Techniques.
Araújo, Gabriela Madeira; Barbalho, Jimmy Charles Melo; Dias, Tasiana Guedes de Souza; Santos, Thiago de Santana; Vasconcellos, Ricardo José de Holanda; de Morais, Hécio Henrique Araújo
2015-11-01
The aim of this randomized, double-blind, controlled trial was to compare the computed and conventional inferior alveolar nerve block techniques in symmetrically positioned inferior third molars. Both computed and conventional anesthetic techniques were performed in 29 healthy patients (58 surgeries) aged between 18 and 40 years. The anesthetic of choice was 2% lidocaine with 1: 200,000 epinephrine. The Visual Analogue Scale assessed the pain variable after anesthetic infiltration. Patient satisfaction was evaluated using the Likert Scale. Heart and respiratory rates, mean time to perform technique, and the need for additional anesthesia were also evaluated. Pain variable means were higher for the conventional technique as compared with computed, 3.45 ± 2.73 and 2.86 ± 1.96, respectively, but no statistically significant differences were found (P > 0.05). Patient satisfaction showed no statistically significant differences. The average computed technique runtime and the conventional were 3.85 and 1.61 minutes, respectively, showing statistically significant differences (P <0.001). The computed anesthetic technique showed lower mean pain perception, but did not show statistically significant differences when contrasted to the conventional technique.
NASA Astrophysics Data System (ADS)
Song, Yong-Ak; Melik, Rohat; Rabie, Amr N.; Ibrahim, Ahmed M. S.; Moses, David; Tan, Ara; Han, Jongyoon; Lin, Samuel J.
2011-12-01
Conventional functional electrical stimulation aims to restore functional motor activity of patients with disabilities resulting from spinal cord injury or neurological disorders. However, intervention with functional electrical stimulation in neurological diseases lacks an effective implantable method that suppresses unwanted nerve signals. We have developed an electrochemical method to activate and inhibit a nerve by electrically modulating ion concentrations in situ along the nerve. Using ion-selective membranes to achieve different excitability states of the nerve, we observe either a reduction of the electrical threshold for stimulation by up to approximately 40%, or voluntary, reversible inhibition of nerve signal propagation. This low-threshold electrochemical stimulation method is applicable in current implantable neuroprosthetic devices, whereas the on-demand nerve-blocking mechanism could offer effective clinical intervention in disease states caused by uncontrolled nerve activation, such as epilepsy and chronic pain syndromes.
NASA Astrophysics Data System (ADS)
Bhadra, Narendra; Foldes, Emily; Vrabec, Tina; Kilgore, Kevin; Bhadra, Niloy
2018-02-01
Objective. Application of kilohertz frequency alternating current (KHFAC) waveforms can result in nerve conduction block that is induced in less than a second. Conduction recovers within seconds when KHFAC is applied for about 5-10 min. This study investigated the effect of repeated and prolonged application of KHFAC on rat sciatic nerve with bipolar platinum electrodes. Approach. Varying durations of KHFAC at signal amplitudes for conduction block with intervals of no stimulus were studied. Nerve conduction was monitored by recording peak Gastrocnemius muscle force utilizing stimulation electrodes proximal (PS) and distal (DS) to a blocking electrode. The PS signal traveled through the block zone on the nerve, while the DS went directly to the motor end-plate junction. The PS/DS force ratio provided a measure of conduction patency of the nerve in the block zone. Main results. Conduction recovery times were found to be significantly affected by the cumulative duration of KHFAC application. Peak stimulated muscle force returned to pre-block levels immediately after cessation of KHFAC delivery when it was applied for less than about 15 min. They fell significantly but recovered to near pre-block levels for cumulative stimulus of 50 ± 20 min, for the tested On/Off times and frequencies. Conduction recovered in two phases, an initial fast one (60-80% recovery), followed by a slower phase. No permanent conduction block was seen at the end of the observation period during any experiment. Significance. This carry-over block effect may be exploited to provide continuous conduction block in peripheral nerves without continuous application of KHFAC.
Sen, Barun Kumar; Pandit, Alak
2018-01-01
Guillain-Barré syndrome (GBS) has unpredictable clinical course with severe complication of respiratory failure. To identify clinical profiles and electrophysiological study particularly non-invasive Phrenic nerve conduction study in patients of early GBS to predict respiratory failure. 64 adult (age≥18yrs) patients of early GBS (onset ≤ 14 days) during the study period from January 2014 to October 2015 were evaluated by clinical profiles of age, gender, antecedent infection, time to peak disability, single breath counts, cranial nerve involvement, autonomic dysfunction and non-invasive Phrenic nerve conduction study. Patients with predisposition factors of polyneuropathy like diabetes mellitus, hypothyroidism, vitamin deficiency, renal failure were excluded. Among 64 patients abnormal phrenic nerve conduction study was seen in 65.62% cases (42/64) and 45.23% (19/42) of them developed respiratory failure. Phrenic nerve sum latency, amplitude, duration and area were abnormal in those who developed respiratory failure and they had sum of phrenic nerve latency >28 msec, sum of CMAP amplitude <300 μV, sum of CMAP duration >50 msec and sum of area < 4 mVmS. None with normal phrenic nerve study developed respiratory failure. It was found that age, gender, preceding infection, autonomic involvement and types of GB syndrome had no influence on development of respiratory failure (p>0.05). Rapid disease progression to peak disability, more severe disease, shorter single breath counts and cranial nerve involvement were seen more often in patients with respiratory failure. Abnormal Phrenic nerve conduction study in the early Guillain-Barré syndrome might be of great value independently in predicting impending respiratory failure.
Sen, Barun Kumar; Pandit, Alak
2018-01-01
Background: Guillain-Barré syndrome (GBS) has unpredictable clinical course with severe complication of respiratory failure. Objective: To identify clinical profiles and electrophysiological study particularly non-invasive Phrenic nerve conduction study in patients of early GBS to predict respiratory failure. Methods: 64 adult (age≥18yrs) patients of early GBS (onset ≤ 14 days) during the study period from January 2014 to October 2015 were evaluated by clinical profiles of age, gender, antecedent infection, time to peak disability, single breath counts, cranial nerve involvement, autonomic dysfunction and non-invasive Phrenic nerve conduction study. Patients with predisposition factors of polyneuropathy like diabetes mellitus, hypothyroidism, vitamin deficiency, renal failure were excluded. Results: Among 64 patients abnormal phrenic nerve conduction study was seen in 65.62% cases (42/64) and 45.23% (19/42) of them developed respiratory failure. Phrenic nerve sum latency, amplitude, duration and area were abnormal in those who developed respiratory failure and they had sum of phrenic nerve latency >28 msec, sum of CMAP amplitude <300 μV, sum of CMAP duration >50 msec and sum of area < 4 mVmS. None with normal phrenic nerve study developed respiratory failure. It was found that age, gender, preceding infection, autonomic involvement and types of GB syndrome had no influence on development of respiratory failure (p>0.05). Rapid disease progression to peak disability, more severe disease, shorter single breath counts and cranial nerve involvement were seen more often in patients with respiratory failure. Conclusion: Abnormal Phrenic nerve conduction study in the early Guillain-Barré syndrome might be of great value independently in predicting impending respiratory failure. PMID:29720799
Sensory nerves are frequently involved in the spectrum of fisher syndrome.
Shahrizaila, Nortina; Goh, Khean J; Kokubun, Norito; Tan, Ai H; Tan, Cheng Y; Yuki, Nobuhiro
2014-04-01
Differing patterns of neurophysiological abnormalities have been reported in patients with Fisher syndrome. Fisher syndrome is rare, and few series have incorporated prospective serial studies to define the natural history of nerve conduction studies in Guillain-Barré syndrome. In an ongoing prospective study of Guillain-Barré syndrome patients, patients who presented with Fisher syndrome and its spectrum of illness were assessed through serial neurological examinations, nerve conduction studies, and serological testing of IgG against gangliosides and ganglioside complexes. Of the 36 Guillain-Barré syndrome patients identified within 2 years, 17 had features of Fisher syndrome. Serial nerve conduction studies detected significant abnormalities in sensory nerve action potential amplitude in 94% of patients associated with 2 patterns of recovery-non-demyelinating reversible distal conduction failure and axonal regeneration. Similar changes were seen in motor nerves of 5 patients. Patients with the Fisher syndrome spectrum of illness have significant sensory involvement, which may only be evident with serial neurophysiological studies. Copyright © 2013 Wiley Periodicals, Inc.
Green, Rylie A; Lovell, Nigel H; Poole-Warren, Laura A
2010-01-01
Conductive neural interfaces tailored for cell interaction by incorporation of bioactive factors are hypothesized to produce superior neuroprostheses with improved charge transfer capabilities. This study examined the effect of entrapping nerve growth factor (NGF) within the conducting polymer poly(ethylene dioxythiophene) (PEDOT) during electrodeposition to create a polymer capable of stimulating neurite outgrowth from proximal neural tissue. NGF entrapment was performed on polymers doped with laminin peptides DEDEDYFQRYLI and DCDPGYIGSR and, additionally, a conventional dopant, paratoluene sulphonate (pTS). All polymer coatings were analysed for a range of physical, electrical and mechanical properties, with the biological activity of ligands examined using a PC12 neurite outgrowth assay. NGF was successfully entrapped in PEDOT during electrodeposition and was shown to produce a softer interface than conventional conducting polymers and films without the NGF modification. However, it was found that the use of a peptide dopant combined with NGF entrapment resulted in polymers with diminished electrical and mechanical stability. Entrapped NGF was determined to be biologically active, with PEDOT/pTS/NGF producing neurite outgrowth comparable with control films where NGF was supplied via the medium. Future studies will determine the effect of typical neural prosthetic stimulation regimes on the release of neurotrophins and subsequent cell response.
Fansa, H; Dodic, T; Wolf, G; Schneider, W; Keilhoff, G
2003-01-01
After a simple nerve lesion, primary microsurgical suture is the treatment of choice. A nerve gap has to be bridged, with a nerve graft sacrificing a functioning nerve. Alternatively, tissue engineering of nerve grafts has become a subject of experimental research. It is evident that nerve regeneration requires not only an autologous, allogenous, or biodegradable scaffold, but additional interactions with regeneration-promoting Schwann cells. In this study, we compared epineurial and acellularized epineurial tubes with and without application of cultured Schwann cells as alternative grafts in a rat sciatic nerve model. Autologous nerve grafts served as controls. Evaluation was performed after 6 weeks; afterwards, sections of the graft and distal nerve were harvested for histological and morphometrical analysis. Compared to controls, all groups showed a significantly lower number of axons, less well-shaped remyelinizated axons, and a delay in clinical recovery (e.g., toe spread). The presented technique with application of Schwann cells into epineurial tubes did not offer any major advantages for nerve regeneration. Thus, in this applied model, neither the implantation of untreated nor the implantation of acellularized epineurial tubes with cultured Schwann cells to bridge nerve defects was capable of presenting a serious alternative to the present gold standard of conventional nerve grafts for bridging nerve defects in this model. Copyright 2003 Wiley-Liss, Inc.
Biomechanical and functional variation in rat sciatic nerve following cuff electrode implantation
2014-01-01
Background Nerve cuff electrodes are commonly and successfully used for stimulating peripheral nerves. On the other hand, they occasionally induce functional and morphological changes following chronic implantation, for reasons not always clear. We hypothesize that restriction of nerve mobility due to cuff implantation may alter nerve conduction. Methods We quantified acute changes in nerve-muscle electrophysiology, using electromyography, and nerve kinematics in anesthetized Sprague Dawley rat sciatic nerves during controlled hindlimb joint movement. We compared electrophysiological and biomechanical response in uncuffed nerves and those secured within a cuff electrode using analysis of variance (ANOVA) and regression analysis. Results Tethering resulting from cuff implantation resulted in altered nerve strain and a complex biomechanical environment during joint movement. Coincident with biomechanical changes, electromyography revealed significantly increased variability in the response of conduction latency and amplitude in cuffed, but not free, nerves following joint movement. Conclusion Our findings emphasize the importance of the mechanical interface between peripheral nerves and their devices on neurophysiological performance. This work has implications for nerve device design, implantation, and prediction of long-term efficacy. PMID:24758405
Methylation-based classification of benign and malignant peripheral nerve sheath tumors.
Röhrich, Manuel; Koelsche, Christian; Schrimpf, Daniel; Capper, David; Sahm, Felix; Kratz, Annekathrin; Reuss, Jana; Hovestadt, Volker; Jones, David T W; Bewerunge-Hudler, Melanie; Becker, Albert; Weis, Joachim; Mawrin, Christian; Mittelbronn, Michel; Perry, Arie; Mautner, Victor-Felix; Mechtersheimer, Gunhild; Hartmann, Christian; Okuducu, Ali Fuat; Arp, Mirko; Seiz-Rosenhagen, Marcel; Hänggi, Daniel; Heim, Stefanie; Paulus, Werner; Schittenhelm, Jens; Ahmadi, Rezvan; Herold-Mende, Christel; Unterberg, Andreas; Pfister, Stefan M; von Deimling, Andreas; Reuss, David E
2016-06-01
The vast majority of peripheral nerve sheath tumors derive from the Schwann cell lineage and comprise diverse histological entities ranging from benign schwannomas and neurofibromas to high-grade malignant peripheral nerve sheath tumors (MPNST), each with several variants. There is increasing evidence for methylation profiling being able to delineate biologically relevant tumor groups even within the same cellular lineage. Therefore, we used DNA methylation arrays for methylome- and chromosomal profile-based characterization of 171 peripheral nerve sheath tumors. We analyzed 28 conventional high-grade MPNST, three malignant Triton tumors, six low-grade MPNST, four epithelioid MPNST, 33 neurofibromas (15 dermal, 8 intraneural, 10 plexiform), six atypical neurofibromas, 43 schwannomas (including 5 NF2 and 5 schwannomatosis associated cases), 11 cellular schwannomas, 10 melanotic schwannomas, 7 neurofibroma/schwannoma hybrid tumors, 10 nerve sheath myxomas and 10 ganglioneuromas. Schwannomas formed different epigenomic subgroups including a vestibular schwannoma subgroup. Cellular schwannomas were not distinct from conventional schwannomas. Nerve sheath myxomas and neurofibroma/schwannoma hybrid tumors were most similar to schwannomas. Dermal, intraneural and plexiform neurofibromas as well as ganglioneuromas all showed distinct methylation profiles. Atypical neurofibromas and low-grade MPNST were indistinguishable with a common methylation profile and frequent losses of CDKN2A. Epigenomic analysis finds two groups of conventional high-grade MPNST sharing a frequent loss of neurofibromin. The larger of the two groups shows an additional loss of trimethylation of histone H3 at lysine 27 (H3K27me3). The smaller one retains H3K27me3 and is found in spinal locations. Sporadic MPNST with retained neurofibromin expression did not form an epigenetic group and most cases could be reclassified as cellular schwannomas or soft tissue sarcomas. Widespread immunohistochemical loss of H3K27me3 was exclusively seen in MPNST of the main methylation cluster, which defines it as an additional useful marker for the differentiation of cellular schwannoma and MPNST.
Time course and predictors of median nerve conduction after carpal tunnel release.
Rotman, Mitchell B; Enkvetchakul, Bobby V; Megerian, J Thomas; Gozani, Shai N
2004-05-01
To identify predictors of outcome and of electrophysiologic recovery in patients with carpal tunnel syndrome (CTS) treated by endoscopic carpal tunnel release using a nerve conduction testing system (NC-Stat; NEUROMetrix, Inc, Waltham, MA). Validity of the automated nerve conduction testing system was shown by comparing presurgical distal motor latencies (DMLs) against a reference obtained by referral to an electromyography laboratory. The DML was evaluated in 48 patients with CTS. Measurements were obtained within 1 hour of surgery and at 2 weeks, 6 weeks, 3 months, and 6 months after carpal tunnel release. Presurgical and postsurgical DMLs were then compared and correlated with variables and possible predictors of outcome including age, body mass index, gender, and presurgical DMLs. The automated nerve conduction testing system DMLs matched those of reference electromyography/nerve conduction study values with high correlation. Sensitivity of the automated nerve conduction testing system when compared with a standardized CTS case definition was 89%, with a specificity of 95%. A significant correlation was found between the DML before release and the DML 1 hour after release. Moreover, maximal postsurgical DML improvement was highly dependent on the presurgical DML, with no improvement shown for the <4-ms group, mild improvement for the 4-to-6-ms group, and maximal improvement in the >6-ms group. Among the clinical variables of age, gender, and body mass index only age was mildly predictive of postrelease DML changes at 6 months. No other correlations between clinical variables and postsurgical DMLs were significant. In addition the predictive value of age was lost when combined with the presurgical DML in a multivariate analysis. Postsurgical changes in the median nerve DML were highly dependent on the prerelease latency. The sensitivity and specificity of a nerve conduction monitoring system in detecting and aiding in the diagnosis of CTS is useful in the long-term management of patients with CTS and can aid in determining the level of improvement in median nerve function after endoscopic carpal tunnel release.
Sensory and motor neuropathy in a Border Collie.
Harkin, Kenneth R; Cash, Walter C; Shelton, G Diane
2005-10-15
A 5-month-old female Border Collie was evaluated because of progressive hind limb ataxia. The predominant clinical findings suggested a sensory neuropathy. Sensory nerve conduction velocity was absent in the tibial, common peroneal, and radial nerves and was decreased in the ulnar nerve; motor nerve conduction velocity was decreased in the tibial, common peroneal, and ulnar nerves. Histologic examination of nerve biopsy specimens revealed considerable nerve fiber depletion; some tissue sections had myelin ovoids, foamy macrophages, and axonal degeneration in remaining fibers. Marked depletion of most myelinated fibers within the peroneal nerve (a mixed sensory and motor nerve) supported the electrodiagnostic findings indicative of sensorimotor neuropathy. Progressive deterioration in motor function occurred over the following 19 months until the dog was euthanatized. A hereditary link was not established, but a littermate was similarly affected. The hereditary characteristic of this disease requires further investigation.
21 CFR 882.1550 - Nerve conduction velocity measurement device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nerve conduction velocity measurement device. 882.1550 Section 882.1550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1550 Nerve...
21 CFR 882.1550 - Nerve conduction velocity measurement device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nerve conduction velocity measurement device. 882.1550 Section 882.1550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1550 Nerve...
Effects of clinical infrared laser on superficial radial nerve conduction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Greathouse, D.G.; Currier, D.P.; Gilmore, R.L.
The purposes of this study were to demonstrate the effects of infrared laser radiation on the sensory nerve conduction of a specified peripheral nerve in man and determine temperature changes in the tissue surrounding the treated nerve. Twenty healthy adults were divided into three groups: control (n = 5); experimental (n = 10), infrared laser radiation at 20 sec/cm2; and experimental (n = 5), infrared laser radiation treatment at 120 sec/cm2. Antidromic sensory nerve conduction studies were performed on the superficial radial nerve of each subject's right forearm. The infrared laser radiation was applied at a fixed intensity for fivemore » 1-cm2 segments. Latency, amplitude, and temperature measurements were recorded pretest; posttest; and posttest intervals of 1, 3, 5, 10, and 15 minutes. An analysis of variance with repeated measures was used to examine the data. No significant change was noted in the distal sensory latency or amplitude of the evoked sensory potential in either experimental or control groups as a result of the applications of the infrared laser radiation treatment. This study demonstrates that infrared laser used at clinically applied intensities does not alter conduction of sensory nerves nor does it elevate the subcutaneous temperature.« less
Whole plantar nerve conduction study with disposable strip electrodes.
Hemmi, Shoji; Kurokawa, Katsumi; Nagai, Taiji; Okamoto, Toshio; Murakami, Tatsufumi; Sunada, Yoshihide
2016-02-01
A new method to evaluate whole plantar nerve conduction with disposable strip electrodes (DSEs) is described. Whole plantar compound nerve action potentials (CNAPs) were recorded at the ankle. DSEs were attached to the sole for simultaneous stimulation of medial and lateral plantar nerves. We also conducted medial plantar nerve conduction studies using an established method and compared the findings. Whole plantar CNAPs were recorded bilaterally from 32 healthy volunteers. Mean baseline to peak amplitude for CNAPs was 26.9 ± 11.8 μV, and mean maximum conduction velocity was 65.8 ± 8.3 m/s. The mean amplitude of CNAPs obtained by our method was 58.2% higher than that of CNAPs obtained by the Saeed method (26.9 μV vs. 17.0 μV; P < 0.0001). The higher mean amplitude of whole plantar CNAPs obtained by our method suggests that it enables CNAPs to be obtained easily, even in elderly people. © 2015 Wiley Periodicals, Inc.
Hato, Naohito; Nota, Jumpei; Komobuchi, Hayato; Teraoka, Masato; Yamada, Hiroyuki; Gyo, Kiyofumi; Yanagihara, Naoaki; Tabata, Yasuhiko
2012-04-01
Basic fibroblast growth factor (bFGF) promotes the regeneration of denervated nerves. The aim of this study was to evaluate the regeneration-facilitating effects of novel facial nerve decompression surgery using bFGF in a gelatin hydrogel in patients with severe Bell palsy. Prospective clinical study. Tertiary referral center. Twenty patients with Bell palsy after more than 2 weeks following the onset of severe paralysis were treated with the new procedure. The facial nerve was decompressed between tympanic and mastoid segments via the mastoid. A bFGF-impregnated biodegradable gelatin hydrogel was placed around the exposed nerve. Regeneration of the facial nerve was evaluated by the House-Brackmann (H-B) grading system. The outcomes were compared with the authors' previous study, which reported outcomes of the patients who underwent conventional decompression surgery (n = 58) or conservative treatment (n = 43). The complete recovery (H-B grade 1) rate of the novel surgery (75.0%) was significantly better than the rate of conventional surgery (44.8%) and conservative treatment (23.3%). Every patient in the novel decompression surgery group improved to H-B grade 2 or better even when undergone between 31 and 99 days after onset. Advantages of this decompression surgery are low risk of complications and long effective period after onset of the paralysis. To the authors' knowledge, this is the first clinical report of the efficacy of bFGF using a new drug delivery system in patients with severe Bell palsy.
Phrenic nerve conduction studies: normative data and technical aspects.
Maranhão, Analucia Abreu; Carvalho, Sonia Regina da Silva; Caetano, Marcelo Ribeiro; Alamy, Alexandre Hofke; Peixoto, Eduardo Mesquita; Filgueiras, Pedro Del Esporte Peçanha
2017-12-01
The aim of the present study was to define normative data of phrenic nerve conduction parameters of a healthy population. Phrenic nerve conduction studies were performed in 27 healthy volunteers. The normative limits for expiratory phrenic nerve compound muscle action potential were: amplitude (0.47 mv - 0.83 mv), latency (5.74 ms - 7.10 ms), area (6.20 ms/mv - 7.20 ms/mv) and duration (18.30 ms - 20.96 ms). Inspiratory normative limits were: amplitude (0.67 mv - 1.11 mv), latency (5.90 ms - 6.34 ms), area (5.62 ms/mv - 6.72 ms/mv) and duration (13.77 ms - 15.37 ms). The best point of phrenic nerve stimulus in the neck varies among individuals between the medial and lateral border of the clavicular head of the sternocleidomastoid muscle and stimulation of both sites, then choosing the best phrenic nerve response, seems to be the appropriate procedure.
Diagnostic utility of F waves in clinically diagnosed patients of carpal tunnel syndrome.
Joshi, Anand G; Gargate, Ashwini R
2013-01-01
Sensory nerve conduction velocity (SNCV) of median nerve measured across the carpal tunnel, difference between distal sensory latencies (DSLs) of median and ulnar nerves and difference between distal motor latencies (DMLs) of median and ulnar nerves are commonly used nerve conduction parameters for diagnosis of carpal tunnel syndrome (CTS). These are having high degree of sensitivity and specificity. Study of median nerve F-wave minimal latency (FWML) and difference between F-wave minimal latencies (FWMLs) of median and ulnar nerves have also been reported to be useful parameters for diagnosis of CTS. However, there is controversy regarding superiority of F-wave study for diagnosis of CTS. So the aim of present study was to compare sensitivity and specificity of median FWML and difference between FWMLs of median and ulnar nerves with that of above mentioned electrophysiological parameters and to find out which parameters are having more sensitivity and specificity, for early diagnosis of CTS. Median and ulnar nerves sensory and motor conduction, median and ulnar nerves F-wave studies were carried out bilaterally in 125 clinically diagnosed patients of carpal tunnel syndrome. These parameters were also studied in 45 age matched controls. Difference between DSLs of median and ulnar nerves, median SNCV and difference between DMLs of median and ulnar nerves were having highest sensitivity and specificity while median FWML and difference between FWMLs of median and ulnar nerves was having lowest sensitivity and specificity for diagnosis of CTS. So in conclusion F-wave study is not superior parameter for diagnosis of CTS.
Shetty, Rohit; Deshpande, Kalyani; Deshmukh, Rashmi; Jayadev, Chaitra; Shroff, Rushad
2016-05-01
To report the case of a 40-year-old patient with persistent bilateral ocular pain and discomfort for 2 years in whom conventional management of dry eye had failed. Detailed ocular examination, meibography, and tear film evaluation were suggestive of bilateral meibomian gland dysfunction and evaporative dry eye. Topical medication failed to alleviate the patient's symptoms. To identify the cause of pain, imaging was performed with in vivo confocal microscopy and anterior segment spectral domain optical coherence tomography. Systemic evaluation revealed severe vitamin D deficiency with a value of 5.86 ng/mL. Case report. In vivo confocal microscopy showed abnormal subbasal nerve plexus morphology, increased dendritic cell density, and enlarged terminal nerve sprouts. A breach in the Bowman layer was detected in both eyes on spectral domain optical coherence tomography. Conventional management having failed, LipiFlow treatment (TearScience, Morrisville, NC) was performed and topical therapy with cyclosporine 0.05%, steroids, and lubricating eye drops was initiated with incomplete symptomatic relief. However, with parenteral therapy for vitamin D deficiency, there was a dramatic improvement in the patient's symptoms. Inflammation aggravated by vitamin D deficiency results in an altered epithelial profile, Bowman layer damage, recruitment of dendritic cells, and altered subbasal nerve plexus features in patients with chronic dry eye disease. These can serve as potential imaging markers for studying the underlying mechanisms in patients with dry eye disease with persisting symptoms despite aggressive conventional treatment.
Median and ulnar neuropathies in university guitarists.
Kennedy, Rachel H; Hutcherson, Kimberly J; Kain, Jennifer B; Phillips, Alicia L; Halle, John S; Greathouse, David G
2006-02-01
Descriptive study. To determine the presence of median and ulnar neuropathies in both upper extremities of university guitarists. Peripheral nerve entrapment syndromes of the upper extremities are well documented in musicians. Guitarists and plucked-string musicians are at risk for entrapment neuropathies in the upper extremities and are prone to mild neurologic deficits. Twenty-four volunteer male and female guitarists (age range, 18-26 years) were recruited from the Belmont University School of Music and the Vanderbilt University Blair School of Music. Individuals were excluded if they were pregnant or had a history of recent upper extremity or neck injury. Subjects completed a history form, were interviewed, and underwent a physical examination. Nerve conduction status of the median and ulnar nerves of both upper extremities was obtained by performing motor, sensory, and F-wave (central) nerve conduction studies. Descriptive statistics of the nerve conduction study variables were computed using Microsoft Excel. Six subjects had positive findings on provocative testing of the median and ulnar nerves. Otherwise, these guitarists had normal upper extremity neural and musculoskeletal function based on the history and physical examinations. When comparing the subjects' nerve conduction study values with a chart of normal nerve conduction studies values, 2 subjects had prolonged distal motor latencies (DMLs) of the left median nerve of 4.3 and 4.7 milliseconds (normal, < 4.2 milliseconds). Prolonged DMLs are compatible with median neuropathy at or distal to the wrist. Otherwise, all electrophysiological variables were within normal limits for motor, sensory, and F-wave (central) values. However, comparison studies of median and ulnar motor latencies in the same hand demonstrated prolonged differences of greater than 1.0 milliseconds that affected the median nerve in 2 additional subjects, and identified contralateral limb involvement in a subject with a prolonged distal latency. The other 20 subjects demonstrated normal comparison studies of the median and ulnar nerves in both upper extremities. In this descriptive study of a population of 24 university guitarists, 4 musicians (17%) were found to have electrophysiologic evidence of median neuropathy at or distal to the wrist or carpal tunnel syndrome. Ulnar nerve electrophysiological function was within normal limits for all subjects examined.
NON-INVASIVE EVALUATION OF NERVE CONDUCTION IN SMALL DIAMETER FIBERS IN THE RAT.
Zotova, Elena G; Arezzo, Joseph C
2013-01-01
A novel non-invasive technique was applied to measure velocity within slow conducting axons in the distal extreme of the sciatic nerve (i.e., digital nerve) in a rat model. The technique is based on the extraction of rectified multiple unit activity (MUA) from in vivo whole nerve compound responses. This method reliably identifies compound action potentials in thinly myelinated fibers conducting at a range of 9-18 m/s (Aδ axons), as well as in a subgroup of unmylinated C fibers conducting at approximately 1-2 m/s. The sensitivity of the method to C-fiber conduction was confirmed by the progressive decrement of the responses in the 1-2 m/s range over a 20-day period following the topical application of capsaicin (ANOVA p <0.03). Increasing the frequency of applied repetitive stimulation over a range of 0.75 Hz to 6.0 Hz produced slowing of conduction and a significant decrease in the magnitude of the compound C-fiber response (ANOVA p <0.01). This technique offers a unique opportunity for the non-invasive, repeatable, and quantitative assessment of velocity in the subsets of Aδ and C fibers in parallel with evaluation of fast nerve conduction.
Liu, Ying; Xu, Xun-cheng; Zou, Yi; Li, Su-rong; Zhang, Bin; Wang, Yue
2015-01-01
Phrenic nerve transfer is a major dynamic treatment used to repair brachial plexus root avulsion. We analyzed 72 relevant articles on phrenic nerve transfer to repair injured brachial plexus that were indexed by Science Citation Index. The keywords searched were brachial plexus injury, phrenic nerve, repair, surgery, protection, nerve transfer, and nerve graft. In addition, we performed neurophysiological analysis of the preoperative condition and prognosis of 10 patients undergoing ipsilateral phrenic nerve transfer to the musculocutaneous nerve in our hospital from 2008 to 201 3 and observed the electromyograms of the biceps brachii and motor conduction function of the musculocutaneous nerve. Clinically, approximately 28% of patients had brachial plexus injury combined with phrenic nerve injury, and injured phrenic nerve cannot be used as a nerve graft. After phrenic nerve transfer to the musculocutaneous nerve, the regenerated potentials first appeared at 3 months. Recovery of motor unit action potential occurred 6 months later and became more apparent at 12 months. The percent of patients recovering ‘excellent’ and ‘good’ muscle strength in the biceps brachii was 80% after 18 months. At 12 months after surgery, motor nerve conduction potential appeared in the musculocutaneous nerve in seven cases. These data suggest that preoperative evaluation of phrenic nerve function may help identify the most appropriate nerve graft in patients with an injured brachial plexus. The functional recovery of a transplanted nerve can be dynamically observed after the surgery. PMID:25883637
Liu, Ying; Xu, Xun-Cheng; Zou, Yi; Li, Su-Rong; Zhang, Bin; Wang, Yue
2015-02-01
Phrenic nerve transfer is a major dynamic treatment used to repair brachial plexus root avulsion. We analyzed 72 relevant articles on phrenic nerve transfer to repair injured brachial plexus that were indexed by Science Citation Index. The keywords searched were brachial plexus injury, phrenic nerve, repair, surgery, protection, nerve transfer, and nerve graft. In addition, we performed neurophysiological analysis of the preoperative condition and prognosis of 10 patients undergoing ipsilateral phrenic nerve transfer to the musculocutaneous nerve in our hospital from 2008 to 201 3 and observed the electromyograms of the biceps brachii and motor conduction function of the musculocutaneous nerve. Clinically, approximately 28% of patients had brachial plexus injury combined with phrenic nerve injury, and injured phrenic nerve cannot be used as a nerve graft. After phrenic nerve transfer to the musculocutaneous nerve, the regenerated potentials first appeared at 3 months. Recovery of motor unit action potential occurred 6 months later and became more apparent at 12 months. The percent of patients recovering 'excellent' and 'good' muscle strength in the biceps brachii was 80% after 18 months. At 12 months after surgery, motor nerve conduction potential appeared in the musculocutaneous nerve in seven cases. These data suggest that preoperative evaluation of phrenic nerve function may help identify the most appropriate nerve graft in patients with an injured brachial plexus. The functional recovery of a transplanted nerve can be dynamically observed after the surgery.
Zhao, Meng; Li, Xiao-yan; Xu, Chun-ying; Zou, Li-ping
2015-01-01
OBJECTIVE: China is the only country where nerve growth factor is approved for large-scale use as a clinical medicine. More than 10 years ago, in 2003, nerve growth factor injection was listed as a national drug. The goal of this article is to evaluate comprehensively the efficacy and safety of nerve growth factor for the treatment of neurological diseases. DATA RETRIEVAL: A computer-based retrieval was performed from six databases, including the Cochrane Library, PubMed, EMBASE, Sino Med, CNKI, and the VIP database, searching from the clinical establishment of nerve growth factor for treatment until December 31, 2013. The key words for the searches were “nerve growth factor, randomized controlled trials” in Chinese and in English. DATA SELECTION: Inclusion criteria: any study published in English or Chinese referring to randomized controlled trials of nerve growth factor; patients with neurological diseases such as peripheral nerve injury, central nerve injury, cranial neuropathy, and nervous system infections; patients older than 7 years; similar research methods and outcomes assessing symptoms; and measurement of nerve conduction velocities. The meta-analysis was conducted using Review Manager 5.2.3 software. MAIN OUTCOME MEASURES: The total effective rate, the incidence of adverse effects, and the nerve conduction velocity were recorded for each study. RESULTS: Sixty-four studies involving 6,297 patients with neurological diseases were included. The total effective rate in the group treated with nerve growth factor was significantly higher than that in the control group (P < 0.0001, RR: 1.35, 95%CI: 1.30–1.40). The average nerve conduction velocity in the nerve growth factor group was significantly higher than that in the control group (P < 0.00001, MD: 4.59 m/s, 95%CI: 4.12–5.06). The incidence of pain or scleroma at the injection site in the nerve growth factor group was also higher than that in the control group (P < 0.00001, RR: 6.30, 95%CI: 3.53–11.27), but such adverse effects were mild. CONCLUSION: Nerve growth factor can significantly improve nerve function in patients with nervous system disease and is safe and effective. PMID:26109961
Avulsion of the brachial plexus in a great horned owl (Bubo virginaus)
Moore, M.P.; Stauber, E.; Thomas, N.J.
1989-01-01
Avulsion of the brachial plexus was documented in a Great Horned Owl (Bubo virginianus). A fractured scapula was also present. Cause of these injuries was not known but was thought to be due to trauma. Differentiation of musculoskeletal injury from peripheral nerve damage can be difficult in raptors. Use of electromyography and motor nerve conduction velocity was helpful in demonstrating peripheral nerve involvement. A brachial plexus avulsion was suspected on the basis of clinical signs, presence of electromyographic abnormalities in all muscles supplied by the nerves of the brachial plexus and absence of median-ulnar motor nerve conduction velocities.
Technique of the sural nerve biopsy.
Bevilacqua, Nicholas J; Rogers, Lee C; Malik, Rayaz A; Armstrong, David G
2007-01-01
A sural nerve biopsy may be useful to enable the clinician to diagnose the etiology and underlying pathology of patients presenting with symptoms of a peripheral neuropathy, when no clear underlying cause has been determined with conventional assessment such as electrophysiology or quantitative sensory testing. Given the prevalence of lower extremity neurological pathology, it is surprising that few descriptions in the peer-reviewed medical literature exist on the rationale and technique for biopsy of the sural nerve. We review the usefulness of this procedure, describe the technique, and discuss the potential complications.
Types of neural guides and using nanotechnology for peripheral nerve reconstruction
Biazar, Esmaeil; Khorasani, MT; Montazeri, Naser; Pourshamsian, Khalil; Daliri, Morteza; T, Mostafa Rezaei; B, Mahmoud Jabarvand; Khoshzaban, Ahad; K, Saeed Heidari; Jafarpour, Mostafa; Roviemiab, Ziba
2010-01-01
Peripheral nerve injuries can lead to lifetime loss of function and permanent disfigurement. Different methods, such as conventional allograft procedures and use of biologic tubes present problems when used for damaged peripheral nerve reconstruction. Designed scaffolds comprised of natural and synthetic materials are now widely used in the reconstruction of damaged tissues. Utilization of absorbable and nonabsorbable synthetic and natural polymers with unique characteristics can be an appropriate solution to repair damaged nerve tissues. Polymeric nanofibrous scaffolds with properties similar to neural structures can be more effective in the reconstruction process. Better cell adhesion and migration, more guiding of axons, and structural features, such as porosity, provide a clearer role for nanofibers in the restoration of neural tissues. In this paper, basic concepts of peripheral nerve injury, types of artificial and natural guides, and methods to improve the performance of tubes, such as orientation, nanotechnology applications for nerve reconstruction, fibers and nanofibers, electrospinning methods, and their application in peripheral nerve reconstruction are reviewed. PMID:21042546
Lin, Pei-Jung; Guo, Yuh-Cherng; Lin, Jan-You; Chang, Yu-Tang
2007-04-01
Surgical excision is thought to be the standard treatment of choice for lymphatic malformations. However, when the lesions are limited to the face only, surgical scar and facial nerve injury may impair cosmetics and facial expression. Sclerotherapy, an injection of a sclerosing agent directly through the skin into a lesion, is an alternative method. By evaluating facial nerve conduction, we observed the long-term effect of facial lymphatic malformations after intralesional injection of OK-432 and correlated the findings with anatomic outcomes. One 12-year-old boy with a lesion over the right-side preauricular area adjacent to the main trunk of facial nerve and the other 5-year-old boy with a lesion in the left-sided cheek involving the buccinator muscle were enrolled. The follow-up data of more than one year, including clinical appearance, computed tomography (CT) scan and facial nerve evaluation were collected. The facial nerve conduction study was normal in both cases. Blink reflex in both children revealed normal results as well. Complete resolution was noted on outward appearance and CT scan. The neurophysiologic data were compatible with good anatomic and functional outcomes. Our report suggests that the inflammatory reaction of OK-432 did not interfere with adjacent facial nerve conduction.
Gerbi, A; Maixent, J M; Ansaldi, J L; Pierlovisi, M; Coste, T; Pelissier, J F; Vague, P; Raccah, D
1999-01-01
Diabetic neuropathy has been associated with a decrease in nerve conduction velocity, Na,K-ATPase activity and characteristic histological damage of the sciatic nerve. The aim of this study was to evaluate the potential effect of a dietary supplementation with fish oil [(n-3) fatty acids] on the sciatic nerve of diabetic rats. Diabetes was induced by intravenous streptozotocin injection. Diabetic animals (n = 20) were fed a nonpurified diet supplemented with either olive oil (DO) or fish oil (DM), and control animals (n = 10) were fed a nonpurified diet supplemented with olive oil at a daily dose of 0.5 g/kg by gavage for 8 wk. Nerves were characterized by their conduction velocity, morphometric analysis and membrane Na, K-ATPase activity. Nerve conduction velocity, as well as Na,K-ATPase activity, was improved by fish oil treatment. A correlation was found between these two variables (R = 0.999, P < 0.05). Moreover, a preventive effect of fish oil was observed on nerve histological damage [endoneurial edema, axonal degeneration (by 10-15%) with demyelination]. Moreover, the normal bimodal distribution of the internal diameter of myelinated fibers was absent in the DO group and was restored in the DM group. These data suggest that fish oil therapy may be effective in the prevention of diabetic neuropathy.
Slower nerve conduction velocity in individuals with functional ankle instability.
Simon, J; Docherty, C
2014-08-01
The purpose of this study is to quantify nerve conduction velocity differences in individuals with functional ankle instability compared to a "healthy" population. 38 participants ages 18-30 were recruited from a large university with approximately 43,000 students. 19 subjects (9 men and 10 women; age=21.0±1.4 years; height=172.0±9.3 cm; mass=74.4±1 2.4 kg) with symptoms of functional ankle instability were in the functional ankle instability group. 19 subjects (10 men, 9 women; age=22.0±2.6 years; height=169.8±9.1 cm; mass=69.0±14.8 kg) with "healthy" ankles were in the control group. Nerve conduction velocity was conducted using one trial at 2 different sites: posterior to the fibular head (fibular), and 10 cm superior/posterior of the first site (popliteal). Nerve conduction velocity (m/sec) was assessed using a SierraWave II system (Cadwell Laboratories; Kennewick, WA). A MANCOVA was performed on the two dependent variables (fibular and popliteal). Covariates included surface temperature of the leg, body mass index, and age. The independent variable was group (functional ankle instability and control). The effect of group was significantly related to nerve conduction velocity at the fibular site (F(1, 27) =16.49, p=0.01) and popliteal site (F(1, 27)=4.51, p=0.01), with responses significantly faster for individuals in the control group than the functional ankle instability group. These results indicate that patients with functional ankle instability might have damage to the peroneal nerve which results in slower peroneal nerve conduction velocity. © Georg Thieme Verlag KG Stuttgart · New York.
Attar, Bijan Movahedian; Zalzali, Haidar; Razavi, Mohammad; Ghoreishian, Mehdi; Rezaei, Majid
2012-10-01
Epineural suturing is the most common technique used for peripheral nerve anastomosis. In addition to the foreign body reaction to the suture material, the surgical duration and difficulty of suturing in confined anatomic locations are major problems. We evaluated the effectiveness of fibrin glue as an acceptable alternative for nerve anastomosis in dogs. Eight adult female dogs weighing 18 to 24 kg were used in the present study. The facial nerve was transected bilaterally. On the right side, the facial nerve was subjected to epineural suturing; and on the left side, the nerve was anastomosed using fibrin adhesive. After 16 weeks, the nerve conduction velocity and proportion of the nerve fibers that crossed the anastomosis site were evaluated and compared for the epineural suture (right side) and fibrin glue (left side). The data were analyzed using the paired t test and univariate analysis of variance. The mean postoperative nerve conduction velocity was 29.87 ± 7.65 m/s and 26.75 ± 3.97 m/s on the right and left side, respectively. No statistically significant difference was found in the postoperative nerve conduction velocity between the 2 techniques (P = .444). The proportion of nerve fibers that crossed the anastomotic site was 71.25% ± 7.59% and 72.25% ± 8.31% on the right and left side, respectively. The histologic evaluation showed no statistically significant difference in the proportion of the nerve fibers that crossed the anastomotic site between the 2 techniques (P = .598). The results suggest that the efficacies of epineural suturing and fibrin gluing in peripheral nerve anastomosis are similar. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Huang, Xusheng; Zhang, Chao; Hu, Ruifa; Li, Yifan; Yin, Yanhong; Chen, Zhaohui; Cai, Jinyang; Cui, Fang
2016-04-27
This study analyzed the associations of farmers' exposure to organophosphates (OPs), organosulfurs (OSs), organonitrogens (ONs) and pyrethroids (PYRs) with parameters of the blood complete counts (CBC), a blood chemistry panel (BCP) and the conventional nerve conduction studies among 224 farmers in China in 2012. Two health examinations and a series of follow-up field surveys were conducted. Multiple linear regression analyses were used to evaluate the associations. The results show considerable associations between multiple groups of pesticides and several CBC parameters, but it was not enough to provide evidence of hematological disorders. The short- and medium-term OPs exposures were mainly associated with liver damage and peripheral nerve impairment, respectively, while OSs exposure might induce liver damage and renal dysfunction. The neurotoxicity of ONs was second only to OPs in addition to its potential liver damage and the induced alterations in glucose. In comparison, the estimated results show that PYRs would be the least toxic in terms of the low-dose application. In conclusion, occupational exposures to pesticides with heterogeneous chemical structures are associated with farmer health in different patterns, and the association between a specific group of pesticides and farmer health also differs between the short- and medium-term exposures.
Wu, Yaobin; Wang, Ling; Guo, Baolin; Shao, Yongpin; Ma, Peter X
2016-05-01
Myelination of Schwann cells (SCs) is critical for the success of peripheral nerve regeneration, and biomaterials that can promote SCs' neurotrophin secretion as scaffolds are beneficial for nerve repair. Here we present a biomaterials-approach, specifically, a highly tunable conductive biodegradable flexible polyurethane by polycondensation of poly(glycerol sebacate) and aniline pentamer, to significantly enhance SCs' myelin gene expression and neurotrophin secretion for peripheral nerve tissue engineering. SCs are cultured on these conductive polymer films, and the biocompatibility of these films and their ability to enhance myelin gene expressions and sustained neurotrophin secretion are successfully demonstrated. The mechanism of SCs' neurotrophin secretion on conductive films is demonstrated by investigating the relationship between intracellular Ca(2+) level and SCs' myelination. Furthermore, the neurite growth and elongation of PC12 cells are induced by adding the neurotrophin medium suspension produced from SCs-laden conductive films. These data suggest that these conductive degradable polyurethanes that enhance SCs' myelin gene expressions and sustained neurotrophin secretion perform great potential for nerve regeneration applications. Copyright © 2016 Elsevier Ltd. All rights reserved.
Promoting peripheral nerve regeneration with biodegradable poly (DL-lactic acid) films
Li, Ruijun; Chen, Lei; Fu, Jinling; Liu, Zhigang; Wang, Shuang; Pan, Yuehai
2015-01-01
Regeneration and repair of peripheral nerve injury has always been a major problem in the clinic. The conventional technique based on suturing the nerve ends to each other coupled with the implantation of nerve conduits outside is associated with postoperative adhesions and scar problems. Recently, a novel biodegradable poly (DL-lactic acid) (PDLLA) film has been introduced. This novel anti-adhesion film has a porous structure with better mechanical properties, better flexibility, and more controllable degradation as compared to traditional non-porous nerve conduits. However, little is known about the effects of such PDLLA films on regeneration and repair of peripheral nerve injury in vivo. In this study, we evaluated the effects of PDLLA films implantation after sciatic nerve transection and anastomosis on subsequent sciatic nerve regeneration in vivo, using a rat sciatic nerve injury model. Sciatic nerve transection surgery coupled with direct suturing only, suturing and wrapping with traditional nerve conduits, or suturing and wrapping with PDLLA films was performed on adult Wistar rats. The additional wrapping with PDLLA films inhibited the nerve adhesion after 12 weeks recovery from surgery. It also increased the compound muscle action potentials and tibialis and gastrocnemius muscle wet weight ratio following 8 weeks recovery from surgery. Regenerated nerve fibers were relatively straight and the aligned structure was complete in rats with implantations of PDLLA films. The results suggested that PDLLA films can improve the nutritional status in the muscles innervated by the damaged nerves and promote nerve regeneration in vivo. PMID:26339372
Suprascapular nerve entrapment in newsreel cameramen.
Karataş, Gülçin Kaymak; Göğüş, Feride
2003-03-01
To determine presence of suprascapular nerve entrapment in a group of newsreel cameramen. Thirty-six men working as newsreel cameramen participated in the study. In addition to musculoskeletal and neurologic examinations, bilateral suprascapular nerve conduction studies and needle electromyography were performed. A group of 19 healthy, male volunteers were included in the study as normal controls for suprascapular nerve conduction studies. In newsreel cameramen, mean suprascapular nerve latency was 3.20 +/- 0.56 msec and 2.84 +/- 0.36 msec for right and left shoulders, respectively (P = 0.001). The mean latency difference between right and left suprascapular nerves was -0.05 +/- 0.19 msec in the control group and 0.36 +/- 0.58 msec in the cameramen group (P < 0.001). Six subjects' right suprascapular nerve motor latencies were 2 SD above the normal mean values. There was no relationship between suprascapular nerve latencies and the age, professional life, and number of hours worked daily by the subjects. Carrying a heavy, mobile camera on the shoulder might cause suprascapular nerve entrapment in newsreel cameramen. This could be considered an occupational disorder of the suprascapular nerve, like meat-packer's neuropathy.
Performance standards of the nerve conduction study technologist.
Neal, Peggy J; Katirji, Bashar
2008-06-01
The primary performance standard of the nerve conduction study technologist is to perform nerve conduction studies (NCS) on patients with trauma or diseases of the peripheral nervous system. However, to be in compliance with various healthcare/medical accreditation agencies, such as Occupational Safety and Health Administration (OSHA), Centers for Disease Control and Prevention (CDC), or The Joint Commission [formerly known as the Joint Commission on Accreditation of Healthcare Organizations (JCAHO)], there are many other important performance objectives that must be met as well. It is the responsibility of the NCS technologist to meet these standards on a daily basis. Once these standards become an expected responsibility of the NCS technologist's position, the patient undergoing a nerve conduction study should be assured of a high quality test performed in an optimal safety environment.
"In Situ Vascular Nerve Graft" for Restoration of Intrinsic Hand Function: An Anatomical Study.
Mozaffarian, Kamran; Zemoodeh, Hamid Reza; Zarenezhad, Mohammad; Owji, Mohammad
2018-06-01
In combined high median and ulnar nerve injury, transfer of the posterior interosseous nerve branches to the motor branch of the ulnar nerve (MUN) is previously described in order to restore intrinsic hand function. In this operation a segment of sural nerve graft is required to close the gap between the donor and recipient nerves. However the thenar muscles are not innervated by this nerve transfer. The aim of the present study was to evaluate whether the superficial radial nerve (SRN) can be used as an "in situ vascular nerve graft" to connect the donor nerves to the MUN and the motor branch of median nerve (MMN) at the same time in order to address all denervated intrinsic and thenar muscles. Twenty fresh male cadavers were dissected in order to evaluate the feasibility of this modification of technique. The size of nerve branches, the number of axons and the tension at repair site were evaluated. This nerve transfer was technically feasible in all specimens. There was no significant size mismatch between the donor and recipient nerves Conclusions: The possible advantages of this modification include innervation of both median and ulnar nerve innervated intrinsic muscles, preservation of vascularity of the nerve graft which might accelerate the nerve regeneration, avoidance of leg incision and therefore the possibility of performing surgery under regional instead of general anesthesia. Briefly, this novel technique is a viable option which can be used instead of conventional nerve graft in some brachial plexus or combined high median and ulnar nerve injuries when restoration of intrinsic hand function by transfer of posterior interosseous nerve branches is attempted.
Unneby, Anna; Svensson, Olle; Gustafson, Yngve; Olofsson, Birgitta
2017-07-01
The number of elderly people with hip fracture and dementia is increasing, and many of these patients suffer from pain. Opioids are difficult to adjust and side effects are common, especially with increased age and among patients with dementia. Preoperative femoral nerve block is an alternative pain treatment. To investigate whether preoperative femoral nerve block reduced acute pain and opioid use after hip fracture among elderly patients, including those with dementia. In this randomised controlled trial involving patients aged ≥70years with hip fracture (trochanteric and cervical), including those with dementia, we compared femoral nerve block with conventional pain management, with opioid use if required. The primary outcome was preoperative pain, measured at five timepoints using a visual analogue scale (VAS). Preoperative opioid consumption was also registered. The study sample comprised 266 patients admitted consecutively to the Orthopaedic Ward. The mean age was 84.1 (±6.9)years, 64% of participants were women, 44% lived in residential care facilities, and 120 (45.1%) had dementia diagnoses. Patients receiving femoral nerve block had significantly lower self-rated pain scores from baseline to 12h after admission than did controls. Self-rated and proxy VAS pain scores decreased significantly in these patients from baseline to 12h compared with controls (p<0.001 and p=0.003, respectively). Patients receiving femoral nerve block required less opioids than did controls, overall (2.3±4.0 vs. 5.7±5.2mg, p<0.001) and in the subgroup with dementia (2.1±3.3 vs. 5.8±5.0mg, p<0.001). Patients with hip fracture, including those with dementia, who received femoral nerve block had lower pain scores and required less opioids before surgery compared with those receiving conventional pain management. Femoral nerve block seems to be a feasible pain treatment for elderly people, including those with dementia. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Touboul, David; Efron, Nathan; Smadja, David; Praud, Delphine; Malet, Florence; Colin, Joseph
2012-11-01
To compare early corneal healing following conventional, transepithelial, and accelerated corneal collagen cross-linking (CXL) protocols. Twenty-four patients with progressive keratoconus were divided into three groups to receive conventional, transepithelial, or accelerated CXL. In vivo corneal confocal microscopy was performed on each patient preoperatively and at 1, 3, and 6 months postoperatively. Closure of the epithelial wound was complete 3 days following conventional and accelerated CXL. The subbasal nerve plexus was essentially obliterated immediately following conventional and accelerated CXL, and virtually no nerve fibers had regenerated by 6 months. The anterior stroma showed significant changes 1 month following conventional CXL; these changes were similar but more pronounced following accelerated CXL. Observed stromal changes included complete obliteration of keratocytes, increased tissue reflectivity, a honeycomb-like appearance, and circular lacunae. Some recovery of keratocyte density was noted after 6 months. These changes were less pronounced in the mid-stroma, and there were no apparent changes to the posterior stroma or endothelium. The cornea appeared to be unaltered following transepithelial CXL. In vivo corneal confocal microscopy analysis of the postoperative impact of CXL on the cornea revealed clear differences among conventional, accelerated, and transepithelial CXL protocols. Accelerated CXL had a greater impact than conventional CXL on the anterior cornea, whereas transepithelial CXL did not appear to alter corneal morphology. Copyright 2012, SLACK Incorporated.
Gonçalves, C; Ribeiro, J; Pereira, T; Luís, A L; Mauricio, A C; Santos, J D; Lopes, M A
2016-08-01
Peripheral nerve regeneration is a serious clinical problem. Presently, there are several nerve tube-guides available in the market, however with some limitations. The goal of this work was the development of a biomaterial with high electrical conductivity to produce tube-guides for nerve regeneration after neurotmesis injuries whenrver an end-to-end suture without tension is not possible. A matrix of poly(vinyl alcohol) (PVA) was used loaded with the following electrical conductive materials: COOH-functionalized multiwall carbon nanotubes (MWCNTs), poly(pyrrole) (PPy), magnesium chloride (MgCl2 ), and silver nitrate (AgNO3 ). The tube-guide production was carried out by a freezing/thawing process (physical crosslinking) with a final annealing treatment. After producing the tube-guide for nerve regeneration, the physicochemical characterization was performed. The most interesting results were achieved by loading PVA with 0.05% of PPy or COOH- functionalized CNTs. These tubes combined the electrical conductivity of carbon nanotubes (CNTs) and PPy with the biocompatibility of PVA matrix, with potential clinical application for nerve regeneration. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 1981-1987, 2016. © 2016 Wiley Periodicals, Inc.
Keilhoff, Gerburg; Prätsch, Florian; Wolf, Gerald; Fansa, Hisham
2005-01-01
Defects of peripheral nerves are bridged with autologous nerve grafts. Tissue-engineered nerve grafts offer a laboratory-based alternative to overcome limited donor nerve availability. Our objective was to evaluate whether a graft made from acellular muscle enriched with cultivated Schwann cells can bridge extra large gaps where conventional conduits usually fail. Our well-established rat sciatic nerve model was used with an increased gap length of 50 mm. The conduits consisted of freeze-thawed or chemically extracted homologous acellular rat rectus muscles and implanted Schwann cells. Autologous nerve grafts were used for control purposes. Biocompatibility of the grafts was demonstrated by Schwann cell settlement, revascularization, and macrophage recruitment. After 12 weeks regeneration was assessed clinically, histologically, and morphometrically. The control group showed superior results regarding axon counts, histologic appearance, and functional recovery compared with the muscle grafts. The chemically extracted conduits completely failed to support nerve regeneration. They were not stable enough to bridge longer nerve gaps with an expanded regeneration time. On the basis of morphological parameters freeze-thawed muscle grafts were, however, able to support peripheral nerve regeneration even over the extralong distance of 50 mm, and therefore are of potential benefit for new therapeutic strategies.
Electrophysiological studies of shoemakers exposed to sub-TLV levels of n-hexane.
Neghab, Masoud; Soleimani, Esmaeel; Khamoushian, Kambiz
2012-01-01
Exposure to n-hexane, a neurotoxic solvent, has been associated with sensorimotor polyneuropathy, both in occupationally exposed workers and in glue-sniffing addicts. The present study was carried out to ascertain whether exposure to sub-TLV levels of n-hexane was associated with electrophysiological abnormalities and to determine if these possible abnormalities have any correlations with parameters such as the biological exposure index (BEI) of this neurotoxic chemical, workers' TWA exposure to n-hexane and/or duration of employment. Twenty-seven asymptomatic male workers from 6 shoemaking workshops were studied and compared with a group of 20 age- and sex-matched normal controls with no history of exposure to any neurotoxic agent. They underwent physical examinations as well as conventional needle electromyographic examinations and sensory and motor nerve conduction studies of upper and lower extremities. The TWA exposure to n-hexane and urinary concentration of free 2,5-hexanedione were also determined. Data were analyzed using version 16.0 of the SPSS/PC statistical package. The TWA exposure to n-hexane was estimated to be 83.2 mg/m(3). Electrophysiological studies showed that the amplitudes of sensory nerve action potential (SAP) for median and sural nerves were significantly lower in exposed subjects than in unexposed normal controls. Additionally, a significant correlation was found between these decreases and the urinary concentration of free 2,5-hexanedione. The significant decrements in SAP amplitudes for the median and sural nerves may be considered as appropriate indicators for early detection of n-hexane-induced peripheral neuropathy in asymptomatic workers with current exposure to sub-TLV levels of n-hexane.
Nanofiber Nerve Guide for Peripheral Nerve Repair and Regeneration
2016-04-01
faster regeneration and functional recovery. Peripheral nerve injury is a common complication of complex tissue trauma and often results in significant...having poor regeneration overall, the areas of regenerating nerve tissue could often be found in sections of the nerve guide where luminal spaces of...conducted in this Aim also provided important insight into the NGC design parameters necessary to allow for maximum nerve tissue ingrowth and regeneration
Aseem, Fazila; Williams, Jessica W; Walker, Francis O; Cartwright, Michael S
2017-06-01
Nerve conduction studies (NCS) are sensitive for carpal tunnel syndrome (CTS), but a small proportion of patients with clinical CTS have normal NCS. This retrospective study was designed to assess the neuromuscular ultrasound findings in a group of CTS patients. The electronic medical record was reviewed by a neurologist to identify patients who had a diagnosis of CTS with normal NCS, including either mixed median-ulnar comparison or transcarpal sensory studies, and complete neuromuscular ultrasound evaluation for CTS. Fourteen individuals (22 wrists) met all criteria. A total of 92.3% had median nerve cross-sectional area enlargement at the wrist (mean 16.3 mm 2 ), 100% had increased wrist-to-forearm median nerve area ratio (mean 2.4), 82.4% had decreased median nerve echogenicity, 75.0% had decreased median nerve mobility, and 7.1% had increased median nerve vascularity. A large proportion of patients with clinical CTS but normal NCS have abnormal neuromuscular ultrasound findings. Muscle Nerve 55: 913-915, 2017. © 2016 Wiley Periodicals, Inc.
Conduction block of mammalian myelinated nerve by local cooling to 15–30°C after a brief heating
Zhang, Zhaocun; Lyon, Timothy D.; Kadow, Brian T.; Shen, Bing; Wang, Jicheng; Lee, Andy; Kang, Audry; Roppolo, James R.; de Groat, William C.
2016-01-01
This study aimed at understanding thermal effects on nerve conduction and developing new methods to produce a reversible thermal block of axonal conduction in mammalian myelinated nerves. In 13 cats under α-chloralose anesthesia, conduction block of pudendal nerves (n = 20) by cooling (5–30°C) or heating (42–54°C) a small segment (9 mm) of the nerve was monitored by the urethral striated muscle contractions and increases in intraurethral pressure induced by intermittent (5 s on and 20 s off) electrical stimulation (50 Hz, 0.2 ms) of the nerve. Cold block was observed at 5–15°C while heat block occurred at 50–54°C. A complete cold block up to 10 min was fully reversible, but a complete heat block was only reversible when the heating duration was less than 1.3 ± 0.1 min. A brief (<1 min) reversible complete heat block at 50–54°C or 15 min of nonblock mild heating at 46–48°C significantly increased the cold block temperature to 15–30°C. The effect of heating on cold block fully reversed within ∼40 min. This study discovered a novel method to block mammalian myelinated nerves at 15–30°C, providing the possibility to develop an implantable device to block axonal conduction and treat many chronic disorders. The effect of heating on cold block is of considerable interest because it raises many basic scientific questions that may help reveal the mechanisms underlying cold or heat block of axonal conduction. PMID:26740534
Pappalardo, Sabrina; Guarnieri, Renzo
2014-07-01
The aim of the present study is to compare piezoelectric surgery to the conventional rotatory surgery in mandibular cyst enucleation, and to determine the 2 method's suitability and the postoperative outcomes. Eighty patients were included in the study. 35 male and 45 female, which showed cystic mandibular lesions, compared with the inferior alveolar nerve or the mental nerve. The patients were randomly divided into two groups. In the test group, cystectomy was performed using conventional rotatory instrumentation (rotatory-group), and in the other one piezoelectric surgery (piezo-group). The swelling was documented 24/48/72 h and 1 week post-surgery and the patients recorded their subjective postoperative pain daily for 7 days using a Visual Analog Scale (VAS). Patients treated with piezoelectric technique have presented a lower VAS, minor swelling and less recovery time compared to the rotatory-group. No lesions of the mandible nerve were detected with piezosurgery whereas surgery with rotary instruments resulted in 8% hypesthesia at least up to one week. The results of this study suggest that piezosurgery may be considered effective in cyst enucleation compared to traditional procedures with burs, since it grants the patients significantly less post-surgical pain and swelling. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Xiaoqiang, Li; Xuerong, Zhang; Juan, Liu; Mathew, Bechu Shelley; Xiaorong, Yin; Qin, Wan; Lili, Luo; Yingying, Zhu; Jun, Luo
2017-12-01
Catheter-related bladder discomfort (CRBD) to an indwelling urinary catheter is defined as a painful urethral discomfort, resistant to conventional opioid therapy, decreasing the quality of postoperative recovery. According to anatomy, the branches of sacral somatic nerves form the afferent nerves of the urethra and bladder triangle, which deriving from the ventral rami of the second to fourth sacral spinal nerves, innervating the urethral muscles and sphincter of the perineum and pelvic floor; as well as providing sensation to the penis and clitoris in males and females, which including the urethra and bladder triangle. Based on this theoretical knowledge, we formed a hypothesis that CRBD could be prevented by pudendal nerve block. To evaluate if bilateral nerve stimulator-guided pudendal nerve block could relieve CRBD through urethra discomfort alleviation. Single-center randomized parallel controlled, double blind trial conducted at West China Hospital, Sichuan University, China. One hundred and eighty 2 male adult patients under general anesthesia undergoing elective trans-urethral resection of prostate (TURP) or trans-urethral resection of bladder tumor (TURBT). Around 4 out of 182 were excluded, 178 patients were randomly allocated into pudendal and control groups, using computer-generated randomized numbers in a sealed envelope method. A total of 175 patients completed the study. Pudendal group received general anesthesia along with nerve-stimulator-guided bilateral pudendal nerve block and control group received general anesthesia only. Incidence and severity of CRBD; and postoperative VAS score of pain. CRBD incidences were significantly lower in pudendal group at 30 minutes (63% vs 82%, P = .004), 2 hours (64% vs 90%, P < .000), 8 hours (58% vs 79%, P = .003) and 12 hours (52% vs 69%, P = .028) also significantly lower incidence of moderate to severe CRBD in pudendal group at 30 minutes (29% vs 57%, P < .001), 2 hours (22% vs 55%, P < .000), 8 hours (8% vs 27%, P = .001) and 12 hours (6% vs 16%, P = .035) postoperatively. The postoperative pain score in pudendal group was lower at 30 minutes (P = .003), 2 hours (P < .001), 8 hours (P < .001), and 12 hours (P < .001), with lower heart rate and mean blood pressure. One patient complained about weakness in levator ani muscle. General anesthesia along with bilateral pudendal nerve block decreased the incidence and severity of CRBD for the first 12 hours postoperatively.
Anoxia increases potassium conductance in hippocampal nerve cells.
Hansen, A J; Hounsgaard, J; Jahnsen, H
1982-07-01
The effect of anoxia on nerve cell function was studied by intra- and extracellular microelectrode recordings from the CA1 and CA3 region in guinea pig hippocampal slices. Hyperpolarization and concomitant reduction of the nerve cell input resistance was observed early during anoxia. During this period the spontaneous activity first disappeared, then the evoked activity gradually disappeared. The hyperpolarization was followed by depolarization and an absence of a measurable input resistance. All the induced changes were reversed when the slice was reoxygenated. Reversal of the electro-chemical gradient for Cl- across the nerve cell membrane did not affect the course of events during anoxia. Aminopyridines blocked the anoxic hyperpolarization and attenuated the decrease of membrane resistance, but had no effect on the later depolarization. Blockers of synaptic transmission. Mn++, Mg++ and of Na+-channels (TTX) were without effect on the nerve cell changes during anoxia. It is suggested that the reduction of nerve cell excitability in anoxia is primarily due to increased K+-conductance. Thus, the nerve cells are hyperpolarized and the input resistance reduced, causing higher threshold and reduction of synaptic potentials. The mechanism of the K+-conductance activation is unknown at present.
End-to-side neurorraphy: a long-term study of neural regeneration in a rat model.
Tarasidis, G; Watanabe, O; Mackinnon, S E; Strasberg, S R; Haughey, B H; Hunter, D A
1998-10-01
This study evaluated long-term reinnervation of an end-to-side neurorraphy and the resultant functional recovery in a rat model. The divided distal posterior tibial nerve was repaired to the side of an intact peroneal nerve. Control groups included a cut-and-repair of the posterior tibial nerve and an end-to-end repair of the peroneal nerve to the posterior tibial nerve. Evaluations included walking-track analysis, nerve conduction studies, muscle mass measurements, retrograde nerve tracing, and histologic evaluation. Walking tracks indicated poor recovery of posterior tibial nerve function in the experimental group. No significant difference in nerve conduction velocities was seen between the experimental and control groups. Gastrocnemius muscle mass measurements revealed no functional recovery in the experimental group. Similarly, retrograde nerve tracing revealed minimal motor neuron staining in the experimental group. However, some sensory staining was seen within the dorsal root ganglia of the end-to-side group. Histologic study revealed minimal myelinated axonal regeneration in the experimental group as compared with findings in the other groups. These results suggest that predominantly sensory regeneration occurs in an end-to-side neurorraphy at an end point of 6 months.
Evidence of VX nerve agent use from contaminated white mustard plants
Gravett, Matthew R.; Hopkins, Farrha B.; Self, Adam J.; Webb, Andrew J.; Timperley, Christopher M.; Baker, Matthew J.
2014-01-01
The Chemical Weapons Convention prohibits the development, production, acquisition, stockpiling, retention, transfer or use of chemical weapons by Member States. Verification of compliance and investigations into allegations of use require accurate detection of chemical warfare agents (CWAs) and their degradation products. Detection of CWAs such as organophosphorus nerve agents in the environment relies mainly upon the analysis of soil. We now present a method for the detection of the nerve agent VX and its hydrolysis products by gas chromatography and liquid chromatography mass spectrometry of ethanol extracts of contaminated white mustard plants (Sinapis alba) which retained the compounds of interest for up to 45 days. VX is hydrolysed by the plants to ethyl methylphosphonic acid and then to methylphosphonic acid. The utility of white mustard as a nerve agent detector and remediator of nerve agent-polluted sites is discussed. The work described will help deter the employment of VX in conflict. PMID:25104906
Changes in lumbosacral spinal nerve roots on diffusion tensor imaging in spinal stenosis.
Hou, Zhong-Jun; Huang, Yong; Fan, Zi-Wen; Li, Xin-Chun; Cao, Bing-Yi
2015-11-01
Lumbosacral degenerative disc disease is a common cause of lower back and leg pain. Conventional T1-weighted imaging (T1WI) and T2-weighted imaging (T2WI) scans are commonly used to image spinal cord degeneration. However, these modalities are unable to image the entire lumbosacral spinal nerve roots. Thus, in the present study, we assessed the potential of diffusion tensor imaging (DTI) for quantitative assessment of compressed lumbosacral spinal nerve roots. Subjects were 20 young healthy volunteers and 31 patients with lumbosacral stenosis. T2WI showed that the residual dural sac area was less than two-thirds that of the corresponding normal area in patients from L3 to S1 stenosis. On T1WI and T2WI, 74 lumbosacral spinal nerve roots from 31 patients showed compression changes. DTI showed thinning and distortion in 36 lumbosacral spinal nerve roots (49%) and abruption in 17 lumbosacral spinal nerve roots (23%). Moreover, fractional anisotropy values were reduced in the lumbosacral spinal nerve roots of patients with lumbosacral stenosis. These findings suggest that DTI can objectively and quantitatively evaluate the severity of lumbosacral spinal nerve root compression.
The rat caudal nerves: a model for experimental neuropathies.
Schaumburg, Herbert H; Zotova, Elena; Raine, Cedric S; Tar, Moses; Arezzo, Joseph
2010-06-01
This study provides a detailed investigation of the anatomy of the rat caudal nerve along its entire length, as well as correlated nerve conduction measures in both large and small diameter axons. It determines that rodent caudal nerves provide a simple, sensitive experimental model for evaluation of the pathophysiology of degeneration, recovery, and prevention of length-dependent distal axonopathy. After first defining the normal anatomy and electrophysiology of the rat caudal nerves, acrylamide monomer, a reliable axonal toxin, was administered at different doses for escalating time periods. Serial electrophysiological recordings were obtained, during intoxication, from multiple sites along caudal and distal sciatic nerves. Multiple sections of the caudal and sciatic nerves were examined with light and electron microscopy. The normal distribution of conduction velocities was determined and acrylamide-induced time- and dose-related slowing of velocities at the vulnerable ultraterminal region was documented. Degenerative morphological changes in the distal regions of the caudal nerves appeared well before changes in the distal sciatic nerves. Our study has shown that (1) rat caudal nerves have a complex neural structure that varies along a distal-to-proximal gradient and (2) correlative assessment of both morphology and electrophysiology of rat caudal nerves is easily achieved and provides a highly sensitive index of the onset and progression of the length-dependent distal axonopathy.
Use of Nerve Conduction Velocity to Assess Peripheral Nerve Health in Aging Mice
Walsh, Michael E.; Sloane, Lauren B.; Fischer, Kathleen E.; Austad, Steven N.; Richardson, Arlan
2015-01-01
Nerve conduction velocity (NCV), the speed at which electrical signals propagate along peripheral nerves, is used in the clinic to evaluate nerve function in humans. A decline in peripheral nerve function is associated with a number of age-related pathologies. While several studies have shown that NCV declines with age in humans, there is little information on the effect of age on NCV in peripheral nerves in mice. In this study, we evaluated NCV in male and female C57Bl/6 mice ranging from 4 to 32 months of age. We observed a decline in NCV in both male and female mice after 20 months of age. Sex differences were detected in sensory NCV as well as the rate of decline during aging in motor nerves; female mice had slower sensory NCV and a slower age-related decline in motor nerves compared with male mice. We also tested the effect of dietary restriction on NCV in 30-month-old female mice. Dietary restriction prevented the age-related decline in sciatic NCV but not other nerves. Because NCV is clinically relevant to the assessment of nerve function, we recommend that NCV be used to evaluate healthspan in assessing genetic and pharmacological interventions that increase the life span of mice. PMID:25477428
Effects of hyperglycemia on rat cavernous nerve axons: a functional and ultrastructural study.
Zotova, Elena G; Schaumburg, Herbert H; Raine, Cedric S; Cannella, Barbara; Tar, Moses; Melman, Arnold; Arezzo, Joseph C
2008-10-01
The present study explored parallel changes in the physiology and structure of myelinated (Adelta) and unmyelinated (C) small diameter axons in the cavernous nerve of rats associated with streptozotocin-induced hyperglycemia. Damage to these axons is thought to play a key role in diabetic autonomic neuropathy and erectile dysfunction, but their pathophysiology has been poorly studied. Velocities in slow conducting fibers were measured by applying multiple unit procedures; histopathology was evaluated with both light and electron microscopy. To our knowledge, these are the initial studies of slow nerve conduction velocities in the distal segments of the cavernous nerve. We report that hyperglycemia is associated with a substantial reduction in the amplitude of the slow conducting response, as well as a slowing of velocities within this very slow range (< 2.5 m/s). Even with prolonged hyperglycemia (> 4 months), histopathological abnormalities were mild and limited to the distal segments of the cavernous nerve. Structural findings included dystrophic changes in nerve terminals, abnormal accumulations of glycogen granules in unmyelinated and preterminal axons, and necrosis of scattered smooth muscle fibers. The onset of slowing of velocity in the distal cavernous nerve occurred subsequent to slowing in somatic nerves in the same rats. The functional changes in the cavernous nerve anticipated and exceeded the axonal degeneration detected by morphology. The physiologic techniques outlined in these studies are feasible in most electrophysiologic laboratories and could substantially enhance our sensitivity to the onset and progression of small fiber diabetic neuropathy.
EFFECTS OF HYPERGLYCEMIA ON RAT CAVERNOUS NERVE AXONS: A FUNCTIONAL AND ULTRASTRUCTURAL STUDY
Zotova, Elena G.; Schaumburg, Herbert H.; Raine, Cedric S.; Cannella, Barbara; Tar, Moses; Melman, Arnold; Arezzo, Joseph C.
2008-01-01
The present study explored parallel changes in the physiology and structure of myelinated (Aδ) and unmyelinated (C) small diameter axons in the cavernous nerve of rats associated with streptozotocin-induced hyperglycemia. Damage to these axons is thought to play a key role in diabetic autonomic neuropathy and erectile dysfunction, but their pathophysiology has been poorly studied. Velocities in slow conducting fibers were measured by applying multiple unit procedures; histopathology was evaluated with both light and electron microscopy. To our knowledge, these are the initial studies of slow nerve conduction velocities in the distal segments of the cavernous nerve. We report that hyperglycemia is associated with a substantial reduction in the amplitude of the slow conducting response, as well as a slowing of velocities within this very slow range (<2.5 m/sec). Even with prolonged hyperglycemia (> 4 months), histopathological abnormalities were mild and limited to the distal segments of the cavernous nerve. Structural findings included dystrophic changes in nerve terminals, abnormal accumulations of glycogen granules in unmyelinated and preterminal axons, and necrosis of scattered smooth muscle fibers. The onset of slowing of velocity in the distal cavernous nerve occurred subsequent to slowing in somatic nerves in the same rats. The functional changes in the cavernous nerve anticipated and exceeded the axonal degeneration detected by morphology. The physiologic techniques outlined in these studies are feasible in most electrophysiologic laboratories and could substantially enhance our sensitivity to the onset and progression of small fiber diabetic neuropathy. PMID:18687329
Bhuyan, Atool Chandra; Latha, Satheesh Sasidharan; Jain, Shefali; Kataki, Rubi
2014-11-01
Pain management remains the utmost important qualifying criteria in minimizing patient agony and establishing a strong dentist-patient rapport. Symptomatic irreversible pulpitis is a painful condition necessitating immediate attention and supplemental anesthetic techniques are often resorted to in addition to conventional inferior alveolar nerve block. The purpose of the study was to evaluate the anesthetic efficacy of X-tip intraosseous injection in patients with symptomatic irreversible pulpitis, in mandibular posterior teeth, using 4% Articaine with 1:100,000 adrenaline as local anesthetic, when the conventional inferior alveolar nerve block proved ineffective. X-tip system was used to administer 1.7 ml of 4% articaine with 1:100,000 adrenaline in 30 patients diagnosed with irreversible pulpitis of mandibular posterior teeth with moderate to severe pain on endodontic access after administration of an inferior alveolar nerve block. The results of the study showed that 25 X-tip injections (83.33%) were successful and 5 X-tip injections (16.66%) were unsuccessful. When the inferior alveolar nerve block fails to provide adequate pulpal anesthesia, X-tip system using 4% articaine with 1:100,000 adrenaline was successful in achieving pulpal anesthesia in patients with irreversible pulpitis.
Bhuyan, Atool Chandra; Latha, Satheesh Sasidharan; Jain, Shefali; Kataki, Rubi
2014-01-01
Introduction: Pain management remains the utmost important qualifying criteria in minimizing patient agony and establishing a strong dentist–patient rapport. Symptomatic irreversible pulpitis is a painful condition necessitating immediate attention and supplemental anesthetic techniques are often resorted to in addition to conventional inferior alveolar nerve block. Aim: The purpose of the study was to evaluate the anesthetic efficacy of X-tip intraosseous injection in patients with symptomatic irreversible pulpitis, in mandibular posterior teeth, using 4% Articaine with 1:100,000 adrenaline as local anesthetic, when the conventional inferior alveolar nerve block proved ineffective. Materials and Methods: X-tip system was used to administer 1.7 ml of 4% articaine with 1:100,000 adrenaline in 30 patients diagnosed with irreversible pulpitis of mandibular posterior teeth with moderate to severe pain on endodontic access after administration of an inferior alveolar nerve block. Results: The results of the study showed that 25 X-tip injections (83.33%) were successful and 5 X-tip injections (16.66%) were unsuccessful. Conclusion: When the inferior alveolar nerve block fails to provide adequate pulpal anesthesia, X-tip system using 4% articaine with 1:100,000 adrenaline was successful in achieving pulpal anesthesia in patients with irreversible pulpitis. PMID:25506137
Kollarik, M; Sun, H; Herbstsomer, R A; Ru, F; Kocmalova, M; Meeker, S N; Undem, B J
2018-04-15
The action potential initiation in the nerve terminals and its subsequent conduction along the axons of afferent nerves are not necessarily dependent on the same voltage-gated sodium channel (Na V 1) subunits. The action potential initiation in jugular C-fibres within airway tissues is not blocked by TTX; nonetheless, conduction of action potentials along the vagal axons of these nerves is often dependent on TTX-sensitive channels. This is not the case for nodose airway Aδ-fibres and C-fibres, where both action potential initiation and conduction is abolished by TTX or selective Na V 1.7 blockers. The difference between the initiation of action potentials within the airways vs. conduction along the axons should be considered when developing Na V 1 blocking drugs for topical application to the respiratory tract. The action potential (AP) initiation in the nerve terminals and its subsequent AP conduction along the axons do not necessarily depend on the same subtypes of voltage-gated sodium channels (Na V 1s). We evaluated the role of TTX-sensitive and TTX-resistant Na V 1s in vagal afferent nociceptor nerves derived from jugular and nodose ganglia innervating the respiratory system. Single cell RT-PCR was performed on vagal afferent neurons retrogradely labelled from the guinea pig trachea. Almost all of the jugular neurons expressed the TTX-sensitive channel Na V 1.7 along with TTX-resistant Na V 1.8 and Na V 1.9. Tracheal nodose neurons also expressed Na V 1.7 but, less frequently, Na V 1.8 and Na V 1.9. Na V 1.6 were expressed in ∼40% of the jugular and 25% of nodose tracheal neurons. Other Na V 1 α subunits were only rarely expressed. Single fibre recordings were made from the vagal nodose and jugular nerve fibres innervating the trachea or lung in the isolated perfused vagally-innervated preparations that allowed for selective drug delivery to the nerve terminal compartment (AP initiation) or to the desheathed vagus nerve (AP conduction). AP initiation in jugular C-fibres was unaffected by TTX, although it was inhibited by Na V 1.8 blocker (PF-01247324) and abolished by combination of TTX and PF-01247324. However, AP conduction in the majority of jugular C-fibres was abolished by TTX. By contrast, both AP initiation and conduction in nodose nociceptors was abolished by TTX or selective Na V 1.7 blockers. Distinction between the effect of a drug with respect to inhibiting AP in the nerve terminals within the airways vs. at conduction sites along the vagus nerve is relevant to therapeutic strategies involving inhaled Na V 1 blocking drugs. © 2018 The Authors. The Journal of Physiology © 2018 The Physiological Society.
Electrodiagnosis of reversible conduction failure in Guillain-Barré syndrome.
Chan, Yee-Cheun; Punzalan-Sotelo, Aubrey M; Kannan, Therimadasamy A; Shahrizaila, Nortina; Umapathi, Thirugnanam; Goh, Eunice J H; Fukami, Yuki; Wilder-Smith, Einar; Yuki, Nobuhiro
2017-11-01
In this study we propose electrodiagnostic criteria for early reversible conduction failure (ERCF) in axonal Guillain-Barré syndrome (GBS) and apply them to a cohort of GBS patients. Serial nerve conduction studies (NCS) were retrospectively analyzed in 82 GBS patients from 3 centers. The criteria for the presence of ERCF in a nerve were: (i) a 50% increase in amplitude of distal compound muscle action potentials or sensory nerve action potentials; or (ii) resolution of proximal motor conduction block with an accompanying decrease in distal latencies or compound muscle action potential duration or increase in conduction velocities. Of 82 patients from 3 centers, 37 (45%) had ERCF, 21 (26%) had a contrasting evolution pattern, and 8 (10%) had both. Sixteen patients did not show an amplitude increase of at least 50%. Our proposed criteria identified a group of patients with a characteristic evolution of NCS abnormality that is consistent with ERCF. Muscle Nerve 56: 919-924, 2017. © 2017 Wiley Periodicals, Inc.
Wali, Ahmad; Kanwar, Dureshahwar; Khan, Safoora A; Khan, Sara
2017-12-01
Acute inflammatory demyelinating polyradiculoneuropathy (AIDP) and acute motor axonal neuropathy are the most common variants of Guillian-Barre syndrome documented in the Asian population. However, the variability of early neurophysiologic findings in the Asian population compared to western data has not been documented. Eighty-seven cases of AIDP were retrospectively reviewed for their demographic, clinical, electrophysiological, and laboratory data. Mean age of subjects was 31 ± 8 years with males more commonly affected. Motor symptoms (97%) at presentation predominated. Common early nerve conduction findings included low motor amplitudes (85%), recordable sural sensory responses (85%), and absent H-reflex responses (65%). Prolonged F-latencies were found most commonly in posterior tibial nerves (23%) in the lower limbs and median and ulnar nerves (18%) in the upper limbs. Blink reflex (BR) studies were performed in 57 patients and were abnormal in 80% of those with clinical facial weakness and in 17 of 52 patients (33%) with no clinical cranial nerve signs, suggesting subclinical cranial nerve involvement. Abnormal motor and sensory amplitudes are seen early. Prolonged distal latencies, temporal dispersion/conduction blocks and sural sparing pattern are other common early nerve conduction study findings of AIDP seen in the Pakistani population. There are no significant differences in abnormalities of conduction velocities and delayed reflex responses compared to published data. The BR can help in the early diagnosis of AIDP. © 2017 Peripheral Nerve Society.
Fujino, Yoshihisa; Guo, Xiaojuan; Shirane, Kiyoyumi; Liu, Jun; Wu, Kegong; Miyatake, Munetoshi; Tanabe, Kimiko; Kusuda, Tetsuya; Yoshimura, Takesumi
2006-09-01
It remains unclear whether chronic ingestion of arsenic in drinking water affects the peripheral nervous system. We examined the effects of arsenic exposure on nerve conduction velocity using electromyography. A cross-sectional study was conducted of a population living in an arsenic-affected village in Hetao Plain, Inner Mongolia, China. A total of 134 (93.7%) of 143 inhabitants took part in the study, and 36 (76.6%) of 47 inhabitants in a low-arsenic exposed village were recruited as a control group. Of the participants, 109 inhabitants in the arsenic-affected village and 32 in the low-arsenic exposed village aged > or =18 years were used for the analyses. An expert physician performed skin examinations, and median nerve conduction velocity was examined by electromyography. Arsenic levels in tube-well water and urine were measured. A mean level of arsenic in tube-well water in the arsenic-affected village was 158.3 microg/L, while that in the low-arsenic exposed village was 5.3 microg/L. No significant differences in the means of the motor nerve conduction velocity (MCV) and sensory nerve conduction velocity (SCV) were observed in relation to arsenic levels in tube wells, urine, and the duration of tube-well use. Further, no differences in mean MCV or SCV were found between the subjects with and without arsenic dermatosis, with mean SCV of 52.8 m/s (SD 6.3) in those without and 54.6 m/s (5.2) in subjects with arsenic dermatosis (p=0.206). These findings suggest that chronic arsenic poisoning from drinking water is unlikely to affect nerve conduction velocity, at least within the range of arsenic in drinking water examined in the present study.
Moorjani, N; Zhao, F; Tian, Y; Liang, C; Kaluba, J; Maiwand, M O
2001-09-01
The choice of analgesia in the management of post-thoracotomy pain remains controversial. Although several alternative forms of post-thoracotomy analgesia exist, all have their disadvantages. Cryoanalgesia, localized freezing of intercostal nerves, has been reported to have variable effectiveness and an incidence of long-term cutaneous sensory changes. We carried out an animal study to assess the reversibility of histological changes induced by cryoanalgesia and a prospective randomized trial to compare the effectiveness of cryoanalgesia with conventional analgesia (parenteral opiates). In six anaesthetized dogs, intercostal nerves were exposed to a varying duration of cryo-application (30, 60, 90 and 120 s). The nerves were biopsied and examined histologically at regular intervals over the following 6 months. In the clinical study, 200 consecutive patients undergoing thoracotomy were randomized to cryoanalgesia and conventional (parenteral opiates) analgesia groups. Postoperative pain scores, respiratory function tests and use of opiate analgesia were measured for the two groups. Following application of the cryoprobe, degeneration and fragmentation of the axons was evident with associated inflammatory changes. As the endoneurium remained intact, axonal regeneration took place after the resolution of axonal swelling. Over the course of weeks, recovery of the intercostal nerve occurred and was complete after 1 month for the 30 and 60 s groups. For nerves exposed to longer durations of cryoanalgesia, the time taken for complete recovery was proportionally increased. Clinically, there was a statistically significant (P<0.05) improvement in postoperative pain scores and use of opiate analgesia and an improvement (P>0.05) in respiratory function tests for patients in the cryoanalgesia group. The previously suggested cutaneous sensory changes resolved within 6 months with complete restoration of function. We suggest that cryoanalgesia be considered as a simple, inexpensive, long-term form of post-thoracotomy pain relief, which does not cause any long-term histological damage to intercostal nerves.
Osman, Ayman M; El-Hammady, Dina H; Kotb, Mohamed M
2016-01-01
Radiofrequency (RF) treatment is a minimally invasive procedure that has been used for more than 3 decades in treating various chronic pain syndromes. Conventional (continuous) RF treatment occasionally results in worsening or even initiating a new type of pain. The use of pulsed radiofrequency (PRF), which has a non- or minimally neurodestructive neuromodulatory effect, serves as an alternative to conventional RF therapy in many medical situations. To evaluate the effect of applying PRF for 6 minutes vs. thermal radiofrequency (TRF) for 90 seconds to the medial calcaneal nerve for treatment of chronic refractory plantar fasciitis pain. Prospective comparative study. Pain, Orthopedic, and Rheumatology and Rehabilitation Clinics of Assiut University Hospital. Twenty patients with refractory chronic bilateral plantar fasciitis received PRF to the medial calcaneal nerve for 6 minutes for one heel and TRF to the same nerve on the other heel (as their own control) for 90 seconds. Numerical verbal rating scale (NVRS) at waking up from bed and after prolonged walking, and satisfaction score were used for assessment of studied patients at one, 3, 6, 12, and 24 weeks from the intervention. All studied patients showed significant improvement in their pain scale after the intervention that lasted for 24 weeks; however, the PRF heels had significantly better pain scale and satisfaction scores at the first and third weeks assessments when compared to the TRF heels. Effective analgesia was achieved after one week or less after PRF compared to 3 weeks for the TRF (P < 0.001). No randomization. PRF to the medial calcaneal nerve is a safe and effective method for treatment of chronic plantar fasciitis pain. The onset of effective analgesia can be achieved more rapidly with PRF compared to TRF on the same nerve. Further randomized trials are needed to confirm the therapeutic effect and optimizing the dose of RF needed.Key words: Pulsed radiofrequency, thermal radiofrequency, medial calcaneal nerve, plantar fasciitis, plantar aponeurosis, visual analogue scale.
Comparison of nerve trimming with the Er:YAG laser and steel knife
NASA Astrophysics Data System (ADS)
Josephson, G. D.; Bass, Lawrence S.; Kasabian, A. K.
1995-05-01
Best outcome in nerve repair requires precise alignment and minimization of scar at the repair interface. Surgeons attempt to create the sharpest cut surface at the nerve edge prior to approximation. Pulsed laser modalities are being investigated in several medical applications which require precise atraumatic cutting. We compared nerve trimming with the Er:YAG laser (1375 J/cm2) to conventional steel knife trimming prior to neurorrhaphy. Sprague- Dawley rats were anesthetized with ketamine and xylazine. Under operating microscope magnification the sciatic nerve was dissected and transected using one of the test techniques. In the laser group, the pulses were directed axially across the nerve using a stage which fixed laser fiber/nerve distance and orientation. Specimens were sent for scanning electron microscopy (SEM) at time zero. Epineurial repairs were performed with 10 - 0 nylon simple interrupted sutures. At intervals to 90 days, specimens were harvested and sectioned longitudinally and axially for histologic examination. Time zero SEM revealed clean cuts in both groups but individual axons were clearly visible in all laser specimens. Small pits were also visible on the cut surface of laser treated nerves. No significant differences in nerve morphology were seen during healing. Further studies to quantify axon counts, and functional outcome will be needed to assess this technique of nerve trimming. Delivery system improvements will also be required, to make the technique clinically practical.
Traditional Japanese medicines inhibit compound action potentials in the frog sciatic nerve.
Matsushita, Akitomo; Fujita, Tsugumi; Ohtsubo, Sena; Kumamoto, Eiichi
2016-02-03
Traditional Japanese (Kampo) medicines have a variety of clinical effects including pain alleviation, but evidence for a mechanism for their pain relief has not yet been elucidated fully. Considering that Kampo medicine contains many plant-derived chemicals having an ability to inhibit nerve action potential conduction, it is possible that this medicine inhibits nerve conduction. The purpose of the present study was to know how various Kampo medicines affect nerve conduction. We examined the effects of Kampo and crude medicines on compound action potentials (CAPs) recorded from the frog sciatic nerve by using the air-gap method. Daikenchuto, rikkosan, kikyoto, rikkunshito, shakuyakukanzoto and kakkonto concentration-dependently reduced the peak amplitude of the CAP. Among the Kampo medicines, daikenchuto was the most effective in inhibiting CAPs. Daikenchuto is composed of three kinds of crude medicine, Japanese pepper, processed ginger and ginseng radix. When the crude medicines were tested, Japanese pepper and processed ginger reduced CAP peak amplitudes, while ginseng radix hardly affected CAPs. Moreover, there was an interaction between the Japanese pepper and processed ginger activities in such that one medicine at low but not high concentrations increased the extent of the inhibition by the other one that was co-applied. Kampo medicines have an ability to inhibit nerve conduction. This action of daikenchuto is due to Japanese pepper and processed ginger but not ginseng radix, probably through an interaction between Japanese pepper and processed ginger in a manner dependent on their concentrations. Nerve conduction inhibition could contribute to at least a part of Kampo medicine's clinical effects such as pain alleviation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
"Nerves": a sociomedical diagnosis ... of sorts.
Ludwig, A M
1982-07-01
"Nerves" represents a common complaint among individuals from Appalachia. It appears to be a conglomerate term to encompass chronic anxiety without panic, mild depression without despair, neurasthenia without malaise, a smattering hypochondriasis and a surfeit of illness behavior, all superimposed on passive, dependent individuals with borderline normal intelligence and exposed to profound sociocultural deprivation. Definitive treatment of this disorder entails major changes or modifications in almost every aspect of their lives, including family structure, education, vocational training, and basic value systems. This may eliminate "nerves" but will not prevent the development of the more conventional psychiatric disorders to which more educated, middle-class individuals are vulnerable.
Reconstruction of the Abdominal Vagus Nerve Using Sural Nerve Grafts in Canine Models
Luo, Fen; Wang, Zhiming; Wang, Yin
2013-01-01
Background Recently, vagus nerve preservation or reconstruction of vagus has received increasing attention. The present study aimed to investigate the feasibility of reconstructing the severed vagal trunk using an autologous sural nerve graft. Methods Ten adult Beagle dogs were randomly assigned to two groups of five, the nerve grafting group (TG) and the vagal resection group (VG). The gastric secretion and emptying functions in both groups were assessed using Hollander insulin and acetaminophen tests before surgery and three months after surgery. All dogs underwent laparotomy under general anesthesia. In TG group, latency and conduction velocity of the action potential in a vagal trunk were measured, and then nerves of 4 cm long were cut from the abdominal anterior and posterior vagal trunks. Two segments of autologous sural nerve were collected for performing end-to-end anastomoses with the cut ends of vagal trunk (8–0 nylon suture, 3 sutures for each anastomosis). Dogs in VG group only underwent partial resections of the anterior and posterior vagal trunks. Laparotomy was performed in dogs of TG group, and latency and conduction velocity of the action potential in their vagal trunks were measured. The grafted nerve segment was removed, and stained with anti-neurofilament protein and toluidine blue. Results Latency of the action potential in the vagal trunk was longer after surgery than before surgery in TG group, while the conduction velocity was lower after surgery. The gastric secretion and emptying functions were weaker after surgery in dogs of both groups, but in TG group they were significantly better than in VG group. Anti-neurofilament protein staining and toluidine blue staining showed there were nerve fibers crossing the anastomosis of the vagus and sural nerves in dogs of TG group. Conclusion Reconstruction of the vagus nerve using the sural nerve is technically feasible. PMID:23555604
Mottaghitalab, Fatemeh; Farokhi, Mehdi; Zaminy, Arash; Kokabi, Mehrdad; Soleimani, Masoud; Mirahmadi, Fereshteh
2013-01-01
As a contribution to the functionality of nerve guide conduits (NGCs) in nerve tissue engineering, here we report a conduit processing technique through introduction and evaluation of topographical, physical and chemical cues. Porous structure of NGCs based on freeze-dried silk/single walled carbon nanotubes (SF/SWNTs) has shown a uniform chemical and physical structure with suitable electrical conductivity. Moreover, fibronectin (FN) containing nanofibers within the structure of SF/SWNT conduits produced through electrospinning process have shown aligned fashion with appropriate porosity and diameter. Moreover, fibronectin remained its bioactivity and influenced the adhesion and growth of U373 cell lines. The conduits were then implanted to 10 mm left sciatic nerve defects in rats. The histological assessment has shown that nerve regeneration has taken places in proximal region of implanted nerve after 5 weeks following surgery. Furthermore, nerve conduction velocities (NCV) and more myelinated axons were observed in SF/SWNT and SF/SWNT/FN groups after 5 weeks post implantation, indicating a functional recovery for the injured nerves. With immunohistochemistry, the higher S-100 expression of Schwann cells in SF/SWNT/FN conduits in comparison to other groups was confirmed. In conclusion, an oriented conduit of biocompatible SF/SWNT/FN has been fabricated with acceptable structure that is particularly applicable in nerve grafts. PMID:24098649
Strotmeyer, Elsa S; de Rekeneire, Nathalie; Schwartz, Ann V; Resnick, Helaine E; Goodpaster, Bret H; Faulkner, Kimberly A; Shorr, Ronald I; Vinik, Aaron I; Harris, Tamara B; Newman, Anne B
2009-11-01
To determine whether sensory and motor nerve function is associated cross-sectionally with quadriceps or ankle dorsiflexion strength in an older community-based population. Cross-sectional analyses within a longitudinal cohort study. Two U.S. clinical sites. Two thousand fifty-nine Health, Aging and Body Composition Study (Health ABC) participants (49.5% male, 36.7% black, aged 73-82) in 2000/01. Quadriceps and ankle strength were measured using an isokinetic dynamometer. Sensory and motor peripheral nerve function in the legs and feet was assessed using 10-g and 1.4-g monofilaments, vibration threshold, and peroneal motor nerve conduction amplitude and velocity. Monofilament insensitivity, poorest vibration threshold quartile (>60 mu), and poorest motor nerve conduction amplitude quartile (<1.7 mV) were associated with 11%, 7%, and 8% lower quadriceps strength (all P<.01), respectively, than in the best peripheral nerve function categories in adjusted linear regression models. Monofilament insensitivity and lowest amplitude quartile were both associated with 17% lower ankle strength (P<.01). Multivariate analyses were adjusted for demographic characteristics, diabetes mellitus, body composition, lifestyle factors, and chronic health conditions and included all peripheral nerve measures in the same model. Monofilament insensitivity (beta=-7.19), vibration threshold (beta=-0.097), and motor nerve conduction amplitude (beta=2.01) each contributed independently to lower quadriceps strength (all P<.01). Monofilament insensitivity (beta=-5.29) and amplitude (beta=1.17) each contributed independently to lower ankle strength (all P<.01). Neither diabetes mellitus status nor lean mass explained the associations between peripheral nerve function and strength. Reduced sensory and motor peripheral nerve function is related to poorer lower extremity strength in older adults, suggesting a mechanism for the relationship with lower extremity disability.
[The role of 2,3-DPG in nerve conduction of children with type 1 diabetes].
Pańkowska, Ewa; Szypowska, Agnieszka; Wysocka, Marta; Lipka, Maria
2005-01-01
Neuropathy is one of the chronic complications of diabetes, and it is uncommon in children and adolescents. It can be recognized in a short period after the onset of diabetes and not always is connected with poor metabolic control. Hypoxia is considered as one from greatest factors diabetic neuropathy and oxygen transport to tissue partially depends on the diphosphoglycerate (2,3 DPG) concentration. As showed recent clinical studies, its concentration in children with diabetes can be abnormal. To assess the role of 2,3 DPG in nerve conduction velocity, as well as qualification of risk factors. To study were included randomly selected 37 patients with diabetes type 1, average age 15.5+/-2.25 years, with a duration of diabetes of more than 5 years (av 9.64+/-1.95 years), treated with intensive insulin therapy (MDI and CSII), without metabolic acidosis pH - 7.35. The nerve conduction velocity was measured in the sensor and motor nerves. HbA1c and 2,3 DPG were assessed additionally. Changes in motor nerve conduction velocity were observed at 22 patients. Average value of HbA1c in the studied group was 8.22+/-1.2%, Average concentration of 2,3 DPG was 6.15+/-1.67 mmol/l (3.84-11 mmol/l), in group with nerve dysfunction was lower - 5.86+/-1.69 mmol/l vs. 6.38+/-1.67, but this difference was not statistically significant. The lower value of 2,3 DPG significantly correlated with abnormal results of electroneurography test, especially with motor and sensor nerve latency (r=-0.34, p=0.038; r=-0.4, p=0.013) but not correlated with HbA1c (r= -0,19;p= 0,25), age of patients (r=0.008; p=0.96) and diabetes duration (r=-0.16; p=0.31). Nerve dysfunction is common in children with type 1 diabetes despite metabolic control and duration of diabetes. 2,3 DPG can be an independent factor of diabetes neuropathy correlated with abnormal value of the nerve conduction test.
Sun, Yuan-Ting; Lin, Thy-Sheng; Tzeng, Shun-Fen; Delpire, Eric; Shen, Meng-Ru
2010-10-01
Nerve conduction requires the fine tuning of ionic currents through delicate interactions between axons and Schwann cells. The K(+)-Cl(-) cotransporter (KCC) family includes four isoforms (KCC1-4) that play an important role in the maintenance of cellular osmotic homeostasis via the coupled electroneutral movement of K(+) and Cl(-) with concurrent water flux. Mutation in SLC12A6 gene encoding KCC3 results in an autosomal recessive disease, known as agenesis of the corpus callosum associated with peripheral neuropathy. Nevertheless, the role of KCC3 in nerve function remains a puzzle. In this study, the microscopic examination of KCC isoforms expressed in peripheral nerves showed high expression of KCC2-4 in nodal segments of the axons and in the perinucleus and microvilli of Schwann cells. The KCC inhibitor [[(dihydroindenyl)oxy]alkanoic acid] but not the Na(+)-K(+)-2Cl(-)-cotransport inhibitor (bumetanide) dose-dependently suppressed the amplitude and area of compound muscle action potential, indicating the involvement of KCC activity in peripheral nerve conduction. Furthermore, the amplitude and area under the curve were smaller, and the nerve conduction velocity was slower in nerves from KCC3(-/-) mice than in nerves from wild-type mice, while the expression pattern of KCC2 and KCC4 was similar in KCC3 kockout and wild-type strains. KCC3(-/-) mice also manifested a prominent motor deficit in the beam-walking test. This is the first study to demonstrate that the K(+)-Cl(-) cotransporter activity of KCC3 contributes to the propagation of action potentials along peripheral nerves. (c) 2010 Wiley-Liss, Inc.
Bovenzi, M; Giannini, F; Rossi, S
2000-11-01
To investigate neural conduction in the upper limbs of symptomatic forestry workers with and without exposure to hand-transmitted vibration. A further aim was to assess the possible relationships between vibration exposure, nerve conduction and finger circulation in the forestry workers who used chain saws. A detailed neurophysiological investigation was performed on the upper extremities of 20 chain saw workers, 20 forestry operators with heavy manual work but without vibration exposure, and 20 healthy male controls. All subjects were screened to exclude polyneuropathy. Measurements of sensory and motor nerve conduction (velocity and amplitude) were obtained bilaterally from the median, ulnar and radial nerves. To assess peripheral vascular function, the forestry workers underwent a cold test with plethysmographic measurement of finger systolic blood pressure (FSBP). In the chain saw operators, vibration exposure was evaluated according to the International Standard ISO 5349. Indices of daily vibration exposure and lifetime cumulative vibration dose were estimated for each chain saw operator. Sensory nerve conduction in several segments of the median and radial nerves was significantly reduced in the chain saw operators compared with that in the workers doing heavy manual work and the controls. The neurophysiological pattern more frequently observed in the chain saw operators was a multifocal nerve conduction impairment to several neural segments with predominant involvement of sensory rather than motor fibres. Sensory nerve conduction velocities in the hands of the chain saw operators were inversely related to both daily and lifetime cumulative vibration exposures. In the vibration-exposed forestry workers, neither were sensori-motor complaints associated with vascular symptoms (finger whiteness) nor were electrophysiological data related to cold-induced changes in FSBP. Exposure to hand-transmitted vibration, in addition to ergonomic stress factors, can contribute to peripheral nerve disorders occurring in forestry workers who operate chain saws. The findings of this study suggest the existence of an exposure-effect relationship for vibration-induced neuropathy. Different underlying mechanisms are likely to be involved in the pathogenesis of the neurological and vascular components of the hand-arm vibration syndrome.
Reja, Abu Hena Hasanoor; De, Abhishek; Biswas, Supratik; Chattopadhyay, Amitabha; Chatterjee, Gobinda; Bhattacharya, Basudev; Sarda, Aarti; Aggarwal, Ishad
2013-01-01
The diagnosis of pure neural leprosy (PNL) remained subjective because of over-dependence of clinical expertise and a lack of simple yet reliable diagnostic tool. The criteria for diagnosis, proposed by Jardim et al., are not routinely done by clinicians in developing country as it involves invasive nerve biopsy and sophisticated anti-PGL-1 detection. We conducted a study using fine needle aspiration cytology (FNAC) coupled with Ziehl Neelsen staining (ZN staining) and Multiplex-Polymerase Chain Reaction (PCR) specific for M. leprae for an objective diagnosis of pure neural leprosy (PNL), which may be simpler and yet reliable. The aim of the study is to couple FNAC with ZN staining and multiplex PCR to diagnose pure neural leprosy patients rapidly, in simpler and yet reliable way. Thirteen patients of PNL as diagnosed by two independent consultants were included as case, and 5 patients other than PNL were taken as control in the study. Fine needle aspiration was done on the affected nerve, and aspirates were evaluated for cytology, ZN staining and multiplex-PCR. Out of the 13 cases where fine needle aspiration was done, M. leprae could be elicited in the nerve tissue aspirates in 5 cases (38.4%) with the help of conventional acid-fast staining and 11 cases (84.6%) with the help of multiplex PCR. On cytological examination of the aspirates, only 3 (23%) cases showed specific epithelioid cells, whereas 8 (61.5%) cases showed non-specific inflammation, and 2 (15.3%) cases had no inflammatory cells. Our study demonstrates that in the field of laboratory diagnosis of PNL cases, FNAC in combination with ZN staining for acid-fast bacilli (AFB) and Multiplex-PCR can provide a rapid and definitive diagnosis for the majority of PNL cases. FNAC is a less-invasive, outdoor-based and simpler technique than invasive nerve biopsy procedure. Thus, this study may enlighten the future path for easy and reliable diagnosis of PNL.
Trnavsky, G
1982-04-30
Measurements about maximal motor nerve conductivity of ulnaris and medianus were carried out before and after constant galvanisation from neck to hand. Significant results of conductivity, distal latency and amplitude of summation potential could not be registered neither by plus nor by minus pole at the hand.
Prolonged phone-call posture causes changes of ulnar motor nerve conduction across elbow.
Padua, Luca; Coraci, Daniele; Erra, Carmen; Doneddu, Pietro Emiliano; Granata, Giuseppe; Rossini, Paolo Maria
2016-08-01
Postures and work-hobby activities may play a role in the origin and progression of ulnar neuropathy at the elbow (UNE), whose occurrence appears to be increasing. The time spent on mobile-phone has increased in the last decades leading to an increased time spent with flexed elbow (prolonged-phone-posture, PPP). We aimed to assess the effect of PPP both in patients with symptoms of UNE and in symptom-free subjects. Patients with pure sensory symptoms of UNE and negative neurophysiological tests (MIN-UNE) and symptom-free subjects were enrolled. We evaluated ulnar motor nerve conduction velocity across elbow at baseline and after 6, 9, 12, 15, and 18min of PPP in both groups. Fifty-six symptom-free subjects and fifty-eight patients were enrolled. Globally 186 ulnar nerves from 114 subjects were studied. Conduction velocity of ulnar nerve across the elbow significantly changed over PPP time in patients with MIN-UNE, showing a different evolution between the two groups. PPP causes a modification of ulnar nerve functionality in patients with MIN-UNE. PPP may cause transient stress of ulnar nerve at elbow. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Duran, Karolina-Petkovic; Zhu, Yonggang; Chen, Chuanpin; Swallow, Anthony; Stewart, Robert; Hoobin, Pam; Leech, Patrick; Ovenden, Simon
2008-12-01
This paper reports on the development of a hand-held device for on-site detection of organophosphonate nerve agent degradation products. This field-deployable analyzer relies on efficient microchip electrophoresis separation of alkyl methylphosphonic acids and their sensitive contactless conductivity detection. Miniaturized, low-powered design is coupled with promising analytical performance for separating the breakdown products of chemical warfare agents such as Soman, Sarin and VX . The detector has a detection limit of about 10 μg/mL and has a good linear response in the range 10-300 μg/mL concentration range. Applicability to environmental samples is demonstrated .The new hand-held analyzer offers great promise for converting conventional ion chromatography or capillary electrophoresis sophisticated systems into a portable forensic laboratory for faster, simpler and more reliable on-site screening.
An electrophysiological follow up of patients with n-hexane polyneuropathy.
Chang, Y C
1991-01-01
Electroneurographic (ENeG) and evoked potential (EP) studies were regularly performed on 11 printing workers with n-hexane polyneuropathy after cessation of exposure. At the initial examination, the ENeG studies simulated a demyelinative process. Further slowing of nerve conduction velocity, or further decreasing of action potential amplitude, or both in the follow up ENeG study were found in about half the patients. The motor distal latency did not worsen. Nerve conduction returned to normal earlier in the sensory than in the motor nerves. After the patients had regained full motor capability, conduction velocities in motor nerves were still significantly slowed. These ENeG characteristics correlate with the pathological and pathophysiological changes in experimental hexa-carbon neuropathies. The initial findings from the EP studies indicated a conduction abnormality in the central nervous system (CNS). Delayed worsening occurred in the amplitude of visual EPs in three patients. On serial follow up, the interpeak latency and interpeak amplitude of visual EPs improved little. Residual abnormalities were also found in the interpeak latency of auditory EPs in the brainstem and in the absolute latency of scalp somatosensory EPs from the peroneal nerve. Astroglial proliferation in the CNS probably impedes recovery of the abnormalities in EP. PMID:1993154
Kimachi, Takeshi; Yuki, Nobuhiro; Kokubun, Norito; Yamaguchi, Shuhei; Wakerley, Benjamin R
2017-02-01
Paraparetic Guillain-Barré syndrome (GBS) is a rare subtype of GBS characterized by leg weakness and areflexia in the absence of neurological involvement of the arms, cranial nerves, or respiratory muscles. Onset is characterized by lower back, buttock, or leg pain, followed by development of symmetric flaccid limb weakness in the absence of sensory disturbance. We describe an elderly woman who developed postinfectious symmetric flaccid leg weakness in the absence of sensory disturbance. Serial nerve conduction studies were carried out over 5 months. Antecedent infection, a monophasic disease course, and the presence of cerebrospinal fluid albuminocytological dissociation suggested a diagnosis of paraparetic GBS. Serial nerve conduction studies demonstrated nondemyelinating reversible conduction failure, which was restricted to the legs. Axonal neuropathy was supported by the presence of anti-GM1 IgG antibodies. These findings suggest that patients with paraparetic GBS have axonal neuropathy, which is restricted to the lower limbs. Muscle Nerve 55: 281-285, 2017. © 2016 Wiley Periodicals, Inc.
Intraoperative cranial nerve monitoring.
Harper, C Michel
2004-03-01
The purpose of intraoperative monitoring is to preserve function and prevent injury to the nervous system at a time when clinical examination is not possible. Cranial nerves are delicate structures and are susceptible to damage by mechanical trauma or ischemia during intracranial and extracranial surgery. A number of reliable electrodiagnostic techniques, including nerve conduction studies, electromyography, and the recording of evoked potentials have been adapted to the study of cranial nerve function during surgery. A growing body of evidence supports the utility of intraoperative monitoring of cranial nerve nerves during selected surgical procedures.
Xiaoqiang, Li; Xuerong, Zhang; Juan, Liu; Mathew, Bechu Shelley; Xiaorong, Yin; Qin, Wan; Lili, Luo; Yingying, Zhu; Jun, Luo
2017-01-01
Abstract Background: Catheter-related bladder discomfort (CRBD) to an indwelling urinary catheter is defined as a painful urethral discomfort, resistant to conventional opioid therapy, decreasing the quality of postoperative recovery. According to anatomy, the branches of sacral somatic nerves form the afferent nerves of the urethra and bladder triangle, which deriving from the ventral rami of the second to fourth sacral spinal nerves, innervating the urethral muscles and sphincter of the perineum and pelvic floor; as well as providing sensation to the penis and clitoris in males and females, which including the urethra and bladder triangle. Based on this theoretical knowledge, we formed a hypothesis that CRBD could be prevented by pudendal nerve block. Objective: To evaluate if bilateral nerve stimulator-guided pudendal nerve block could relieve CRBD through urethra discomfort alleviation. Design and Setting: Single-center randomized parallel controlled, double blind trial conducted at West China Hospital, Sichuan University, China. Participants: One hundred and eighty 2 male adult patients under general anesthesia undergoing elective trans-urethral resection of prostate (TURP) or trans-urethral resection of bladder tumor (TURBT). Around 4 out of 182 were excluded, 178 patients were randomly allocated into pudendal and control groups, using computer-generated randomized numbers in a sealed envelope method. A total of 175 patients completed the study. Intervention: Pudendal group received general anesthesia along with nerve-stimulator-guided bilateral pudendal nerve block and control group received general anesthesia only. Main outcome measures: Incidence and severity of CRBD; and postoperative VAS score of pain. Results: CRBD incidences were significantly lower in pudendal group at 30 minutes (63% vs 82%, P = .004), 2 hours (64% vs 90%, P < .000), 8 hours (58% vs 79%, P = .003) and 12 hours (52% vs 69%, P = .028) also significantly lower incidence of moderate to severe CRBD in pudendal group at 30 minutes (29% vs 57%, P < .001), 2 hours (22% vs 55%, P < .000), 8 hours (8% vs 27%, P = .001) and 12 hours (6% vs 16%, P = .035) postoperatively. The postoperative pain score in pudendal group was lower at 30 minutes (P = .003), 2 hours (P < .001), 8 hours (P < .001), and 12 hours (P < .001), with lower heart rate and mean blood pressure. One patient complained about weakness in levator ani muscle. Conclusion: General anesthesia along with bilateral pudendal nerve block decreased the incidence and severity of CRBD for the first 12 hours postoperatively. PMID:29245259
Hotta, N; Nakamura, J; Kakuta, H; Fukasawa, H; Koh, N; Sakakibara, F; Mori, K; Sakamoto, N
1995-01-01
Nerve ischemia/hypoxia has been linked to the pathogenesis of diabetic complications. Red blood cell 2,3-diphosphoglycerate is an important regulator of peripheral tissue oxygenation; however, the relationship between 2,3-diphosphoglycerate concentration and diabetic complications has not been studied in detail. This investigation focused on the relationship between red blood cell 2,3-diphosphoglycerate and diabetic neuropathy, by measuring motor nerve conduction velocity and sciatic nerve blood flow in streptozotocin-induced diabetic rats. The effect of treatment with niceritrol, a nicotinic acid derivative that acts as a vasodilator and reduces serum lipid concentrations, on 2,3-diphosphoglycerate concentration and diabetic neuropathy was also examined. Untreated diabetic rats had significantly lower concentrations of red blood cell 2,3-diphosphoglycerate, higher concentrations of serum total cholesterol and triglyceride, as well as reduced motor nerve conduction velocity and sciatic nerve blood flow, compared to untreated normal rats. Niceritrol prevented these abnormalities without correcting hyperglycemia in diabetic rats, but had no effect on these parameters in normal rats. Red blood cell 2,3-diphosphoglycerate concentration and motor nerve conduction velocity showed a positive correlation with sciatic nerve blood flow and 2,3-diphosphoglycerate, respectively. These observations suggest that ischemia/hypoxia plays an important role in the development of diabetic neuropathy, and that niceritrol has a therapeutic effect on this condition by improving endoneurial ischemia/hypoxia.
Ginanneschi, Federica; Filippou, Georgios; Giannini, Fabio; Carluccio, Maria A; Adinolfi, Antonella; Frediani, Bruno; Dotti, Maria T; Rossi, Alessandro
2012-12-01
In hereditary neuropathy with liability to pressure palsies (HNPP), the increase in distal motor latencies (DMLs) is often out of proportion to the slowing of conduction velocities, but the pathophysiological mechanism is still unclear. We used a combined electrophysiological and ultrasonographic (US) approach to provide insight into this issue. Twelve HNPP subjects underwent extensive electrophysiological studies and US measurements of the cross-sectional area (CSA) of several peripheral nerves. US nerve enlargement was only observed in the carpal tunnel, Guyon's canal, the elbow and the fibular head. We did not observe US abnormalities at sites where nerve entrapment is uncommon. An increase in DMLs was observed regardless of US nerve enlargement. The increased nerve CSA only in common sites of entrapment likely reflected the well-documented nerve vulnerability to mechanical stress in HNPP. No morphometric changes were seen in the distal nerve segments where compression/entrapment is unlikely, despite the fact that the DMLs were increased. These data suggest that factors other than mechanical stress are responsible for the distal slowing of action potential propagation. We speculate that a mixture of mechanical insults and an axon-initiated process in the distal nerves underlies the distal slowing and/or conduction failure in HNPP. © 2012 Peripheral Nerve Society.
Peripheral choline acetyltransferase in rat skin demonstrated by immunohistochemistry.
Hanada, Keiji; Kishimoto, Saburo; Bellier, Jean-Pierre; Kimura, Hiroshi
2013-03-01
Conventional choline acetyltransferase immunohistochemistry has been used widely for visualizing central cholinergic neurons and fibers but not often for labeling peripheral structures, probably because of their poor staining. The recent identification of the peripheral type of choline acetyltransferase (pChAT) has enabled the clear immunohistochemical detection of many known peripheral cholinergic elements. Here, we report the presence of pChAT-immunoreactive nerve fibers in rat skin. Intensely stained nerve fibers were distributed in association with eccrine sweat glands, blood vessels, hair follicles and portions just beneath the epidermis. These results suggest that pChAT-positive nerves participate in the sympathetic cholinergic innervation of eccrine sweat glands. Moreover, pChAT also appears to play a role in cutaneous sensory nerve endings. These findings are supported by the presence of many pChAT-positive neuronal cells in the sympathetic ganglion and dorsal root ganglion. Thus, pChAT immunohistochemistry should provide a novel and unique tool for studying cholinergic nerves in the skin.
Wanner, Laura; Ludwig, Ute; Hövener, Jan-Bernd; Nelson, Katja; Flügge, Tabea
2018-04-01
Compared with cone beam computed tomography (CBCT), magnetic resonance imaging (MRI) might be superior for the diagnosis of nerve lesions associated with implant placement. A patient presented with unilateral pain associated with dysesthesia in the region of the right lower lip and chin after implant placement. Conventional orthopantomography could not identify an association between the position of the inferior alveolar nerve and the implant. For 3-dimensional display of the implant in relation to the surrounding anatomy, CBCT was compared with MRI. MRI enabled the precise depiction of the implant position and its spatial relation to the inferior alveolar nerve, whereas the nerve position and its exact course within the mandible could not be directly displayed in CBCT. MRI may be a valuable, radiation-free diagnostic tool for the visualization of intraoral hard and soft tissues, offering an objective assessment of nerve injuries by a direct visualization of the inferior alveolar neurovascular bundle. Copyright © 2018 Elsevier Inc. All rights reserved.
Wu, Yaobin; Wang, Ling; Hu, Tianli; Ma, Peter X; Guo, Baolin
2018-05-15
Controlling cellular alignment and elongation has been demonstrated as an important parameter for developing nerve tissue engineering scaffolds. Many approaches have been developed to guide cellular orientation for nerve regeneration such as micropatterning techniques. However, most of materials used for developing micropatterning scaffolds lack of bioactivity and biofunctionability. Here we present a functional conductive micropatterned scaffold based on bioactive conductive biodegradable polyurethane prepared using a micro-molding technique. These conductive micropatterned scaffolds are able to not only induce the Schwann cells (SCs) alignment and elongation by the micropatterned surface but also enhance the nerve growth factor (NGF) gene expression of SCs by the bioactivity of these materials. Additionally, the combined effect of the bioactivity of such conductive materials and the micropatterned structure also dramatically promotes the neurite extension and elongation of PC12 cells in a highly aligned direction. These data suggest that these conductive micropatterned scaffolds that easily control cellular orientation and organization, and dramatically enhance NGF gene expression and significantly induce the neurite extension of PC12 cells, have a great potential for nerve regeneration applications. Copyright © 2018 Elsevier Inc. All rights reserved.
Rose, A; Suttor, S; Goebell, P J; Rossi, R; Rübben, H
2007-09-01
Transurethral resection in a conductive irrigant medium is a new procedure in the surgical therapy of bladder tumors and prostate enlargement. In this prospective randomized trial we compared conventional TUR with TUR in saline regarding safety and efficiency. Between November 2004 and February 2005 a total number of 128 patients were included in this study. After randomization 58 patients were treated by conventional TUR and 70 patients by TURIS (Olympus, SurgMasterSystem). We evaluated resection time, weight of resected tissue, complications, blood loss, changes in serum sodium, and duration of catheterization. Among the tested procedures no statistically significant difference could be observed concerning blood loss, change of serum sodium, and complications. The mean weight of resected tissue of the prostate per time was 0.9 g/min with the TUR procedure and 0.8 g/min with the TURIS procedure. Severe complications like TUR syndrome or perforation of the bladder were not observed at all. In the TURIS group time until catheter removal was longer but also the mean weight of resected tissue of the prostate was higher in the TURIS group (42 g) than in the conventional TUR group (31 g). Transurethral resection in a conductive irrigant medium (TURIS) can be considered as a safe and effective surgical procedure in the treatment of BPH and superficial urothelial carcinoma. Moreover the risk of TUR syndrome and perforation of the bladder due to nerve stimulation is reduced.
Turning Electromyography Reports Upside Down: A Pilot Study Surveying Referring Providers
Shenoy, Anant M.; Baquis, Kate G.; Baquis, George D.
2016-01-01
Providers are expressing a desire for more efficient ways to retrieve relevant clinical data from the Electronic Health Record. In an effort to improve our Electromyography and Nerve Conduction Study reports, we surveyed referring providers on the effects of having the IMPRESSION at the start of the report. Our survey respondents felt that using this format for an Electromyography and Nerve Conduction Study report significantly improved the quality of the report while saving them time and/or mouse clicks when interpreting the report. Electro diagnosticians might consider using this format for their Electromyography and Nerve Conduction Study reports to improve referring provider satisfaction. PMID:27708744
Reversible conduction block in peripheral nerve using electrical waveforms.
Bhadra, Niloy; Vrabec, Tina L; Bhadra, Narendra; Kilgore, Kevin L
2018-01-01
Electrical nerve block uses electrical waveforms to block action potential propagation. Two key features that distinguish electrical nerve block from other nonelectrical means of nerve block: block occurs instantly, typically within 1 s; and block is fully and rapidly reversible (within seconds). Approaches for achieving electrical nerve block are reviewed, including kilohertz frequency alternating current and charge-balanced polarizing current. We conclude with a discussion of the future directions of electrical nerve block. Electrical nerve block is an emerging technique that has many significant advantages over other methods of nerve block. This field is still in its infancy, but a significant expansion in the clinical application of this technique is expected in the coming years.
Renaut bodies in nerves of the trunk of the African elephant, Loxodonta africana.
Witter, Kirsti; Egger, Gunter F; Boeck, Peter
2007-05-01
Renaut bodies are loosely textured, cell-sparse structures in the subperineurial space of peripheral nerves, frequently found at sites of nerve entrapment. The trunk of the elephant is a mobile, richly innervated organ, which serves for food gathering, object grasping and as a tactile organ. These functions of the trunk lead to distortion and mechanical compression of its nerves, which can therefore be expected to contain numerous Renaut bodies. Samples of the trunk wall of an adult African elephant (Loxodonta africana) were examined histologically using conventional staining methods, immunohistochemistry, and lectin histochemistry. Architecture of nerve plexuses and occurrence of Renaut bodies in the elephant trunk were compared with those in tissues surrounding the nasal vestibule of the pig. Prominent nerve plexuses were found in all layers of the elephant trunk. Almost all (81%) nerve profiles contained Renaut bodies, a basophilic, discrete subperineurial layer resembling cushions around the nerve core. In contrast, Renaut bodies were seen in only 15% of nerve profiles in the porcine nasal vestibule. Within Renaut bodies, fusiform fibroblasts and round, ruff-like cells were placed into a matrix of acidic glycosaminoglycans with delicate collagen and very few reticular fibers. The turgor of this matrix is thought to protect nerves against compression and shearing strain. Renaut bodies are readily stained with alcian blue (pH 2.5) favorably in combination with immunohistochemical markers of nerve fibers. They should be regarded as a physiological response to repeated mechanical insults and are distinct from pathological alterations. alterations. (c) 2007 Wiley-Liss, Inc.
Johnson, Thomas M; Badovinac, Rachel; Shaefer, Jeffry
2007-09-01
Surveys were sent to Harvard School of Dental Medicine students and graduates from the classes of 2000 through 2006 to determine their current primary means of achieving mandibular anesthesia. Orthodontists and orthodontic residents were excluded. All subjects received clinical training in the conventional inferior alveolar nerve block and two alternative techniques (the Akinosi mandibular block and the Gow-Gates mandibular block) during their predoctoral dental education. This study tests the hypothesis that students and graduates who received training in the conventional inferior alveolar nerve block, the Akinosi mandibular block, and the Gow-Gates mandibular block will report more frequent current utilization of alternatives to the conventional inferior alveolar nerve block than clinicians trained in the conventional technique only. At the 95 percent confidence level, we estimated that between 3.7 percent and 16.1 percent (mean=8.5 percent) of clinicians trained in using the Gow-Gates technique use this injection technique primarily, and between 35.4 percent and 56.3 percent (mean=47.5 percent) of those trained in the Gow-Gates method never use this technique. At the same confidence level, between 0.0 percent and 3.8 percent (mean=0.0 percent) of clinicians trained in using the Akinosi technique use this injection clinical technique primarily, and between 62.2 percent and 81.1 percent (mean=72.3 percent) of those trained in the Akinosi method never use this technique. No control group that was completely untrained in the Gow-Gates or Akinosi techniques was available for comparison. However, we presume that zero percent of clinicians who have not been trained in a given technique will use the technique in clinical practice. The confidence interval for the Gow-Gates method excludes this value, while the confidence interval for the Akinosi technique includes zero percent. We conclude that, in the study population, formal clinical training in the Gow-Gates and Akinosi injection techniques lead to a small but significant increase in current primary utilization of the Gow-Gates technique. No significant increase in current primary utilization of the Akinosi technique was found.
Cold Exposure Exacerbates the Development of Diabetic Polyneuropathy in the Rat
Kasselman, Lora J.; Veves, Aristidis; Gibbons, Christopher H.; Rutkove, Seward B.
2009-01-01
Diabetic polyneuropathy (DPN) and cold-induced nerve injury share several pathogenic mechanisms. This study explores whether cold exposure contributes to the development of DPN. Streptozotocin-induced diabetic rats and controls were exposed to a room temperature (23°C) or cold environment (10°C). H-reflex, tail and sciatic motor, and sensory nerve conduction studies were performed. Analyses of sural nerve, intraepidermal nerve fibers, and skin and nerve nitrotyrosine ELISAs were performed. Diabetic animals exposed to a cold environment had an increased H-reflex four weeks earlier than diabetic room temperature animals (P = .03). Cold-exposed diabetic animals also had greater reduction in motor conduction velocities at 20 weeks (P = .017), decreased skin nerve fiber density (P = .037), and increased skin nitrotyrosine levels (P = .047). Cold exposure appears to hasten the development of DPN in the rat STZ model of diabetes. These findings support that further study into the relationship between ambient temperature and DPN is warranted. PMID:20130819
Yang, Ming-liang; Li, Jian-jun; Zhang, Shao-cheng; Du, Liang-jie; Gao, Feng; Li, Jun; Wang, Yu-ming; Gong, Hui-ming; Cheng, Liang
2011-08-01
The authors report a case of functional improvement of the paralyzed diaphragm in high cervical quadriplegia via phrenic nerve neurotization using a functional spinal accessory nerve. Complete spinal cord injury at the C-2 level was diagnosed in a 44-year-old man. Left diaphragm activity was decreased, and the right diaphragm was completely paralyzed. When the level of metabolism or activity (for example, fever, sitting, or speech) slightly increased, dyspnea occurred. The patient underwent neurotization of the right phrenic nerve with the trapezius branch of the right spinal accessory nerve at 11 months postinjury. Four weeks after surgery, training of the synchronous activities of the trapezius muscle and inspiration was conducted. Six months after surgery, motion was observed in the previously paralyzed right diaphragm. The lung function evaluation indicated improvements in vital capacity and tidal volume. This patient was able to sit in a wheelchair and conduct outdoor activities without assisted ventilation 12 months after surgery.
Sabetian, Parisa; Sadeghlo, Bita; Zhang, Chengran Harvey; Yoo, Paul B
2017-02-01
Tripolar nerve cuff electrodes have been widely used for measuring peripheral nerve activity. However, despite the high signal-to-noise ratio levels that can be achieved with this recording configuration, the clinical use of cuff electrodes in closed-loop controlled neuroprostheses remains limited. This is largely attributed to artifact noise signals that contaminate the recorded neural activity. In this study, we investigated the use of a conductive shield layer (CSL) as a means of reducing the artifact noise recorded by nerve cuff electrodes. Using both computational simulations and in vivo experiments, we found that the CSL can result in up to an 85% decrease in the recorded artifact signal. Both the electrical conductivity and the surface area of the CSL were identified as important design criteria. Although this study shows that the CSL can significantly reduce artifact noise in tripolar nerve cuff electrodes, long-term implant studies are needed to validate our findings. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Chitosan conduits combined with nerve growth factor microspheres repair facial nerve defects
Liu, Huawei; Wen, Weisheng; Hu, Min; Bi, Wenting; Chen, Lijie; Liu, Sanxia; Chen, Peng; Tan, Xinying
2013-01-01
Microspheres containing nerve growth factor for sustained release were prepared by a compound method, and implanted into chitosan conduits to repair 10-mm defects on the right buccal branches of the facial nerve in rabbits. In addition, chitosan conduits combined with nerve growth factor or normal saline, as well as autologous nerve, were used as controls. At 90 days post-surgery, the muscular atrophy on the right upper lip was more evident in the nerve growth factor and normal sa-line groups than in the nerve growth factor-microspheres and autologous nerve groups. physiological analysis revealed that the nerve conduction velocity and amplitude were significantly higher in the nerve growth factor-microspheres and autologous nerve groups than in the nerve growth factor and normal saline groups. Moreover, histological observation illustrated that the di-ameter, number, alignment and myelin sheath thickness of myelinated nerves derived from rabbits were higher in the nerve growth factor-microspheres and autologous nerve groups than in the nerve growth factor and normal saline groups. These findings indicate that chitosan nerve conduits bined with microspheres for sustained release of nerve growth factor can significantly improve facial nerve defect repair in rabbits. PMID:25206635
Zhu, Yaohui; Huizinga, Jan D
2008-01-01
Abstract Nitrergic nerves are structurally and functionally associated with ICC. To further understand mechanisms of communication, the hypothesis was investigated that NO might affect large conductance K channels. To that end, we searched for IbTX-sensitive currents in ICC obtained through explant cultures from the mouse small intestine and studied effects of the NOS inhibitor omega N-nitro-L-arginine (LNNA) and the NO donor sodium nitroprusside (SNP). IbTX-sensitive currents acquired in the whole-cell configuration through nystatin perforated patches exhibited high noise levels but relatively low amplitude, whereas currents obtained in the conventional whole-cell configuration exhibited less noise and higher amplitudes; depolarization from −80 to + 40 mV evoked 357 ± 159 pA current in the nystatin perforated patch configuration and 1075 ± 597 pA using the conventional whole-cell configuration. Immunohistochemistry showed that ICC associated with ganglia and Auerbach's plexus nerve fibers were immunoreactive to BK antibodies. The IbTX-sensitive currents were increased by SNP and inhibited by LNNA. BK blockers suppressed spontaneous transit outward currents in ICC. After block of BK currents, or before these currents became prominent, calcium currents were activated by depolarization in the same cells. Their peak amplitude occurred at −25 mV and the currents were increased with increasing extracellular calcium and inhibited by cobalt. The hypothesis is warranted that nitrergic innervation inhibits ICC excitability in part through activation of BK channels. In addition, NO is an intracellular regulator of ICC excitability. PMID:18194464
Wolf, Marcel; Bäumer, Philipp; Pedro, Maria; Dombert, Thomas; Staub, Frank; Heiland, Sabine; Bendszus, Martin; Pham, Mirko
2014-01-01
Sciatic nerve palsy related to hip replacement surgery (HRS) is among the most common causes of sciatic neuropathies. The sciatic nerve may be injured by various different periprocedural mechanisms. The precise localization and extension of the nerve lesion, the determination of nerve continuity, lesion severity, and fascicular lesion distribution are essential for assessing the potential of spontaneous recovery and thereby avoiding delayed or inappropriate therapy. Adequate therapy is in many cases limited to conservative management, but in certain cases early surgical exploration and release of the nerve is indicated. Nerve-conduction-studies and electromyography are essential in the diagnosis of nerve injuries. In postsurgical nerve injuries, additional diagnostic imaging is important as well, in particular to detect or rule out direct mechanical compromise. Especially in the presence of metallic implants, commonly applied diagnostic imaging tests generally fail to adequately visualize nervous tissue. MRI has been deemed problematic due to implant-related artifacts after HRS. In this study, we describe for the first time the spectrum of imaging findings of Magnetic Resonance neurography (MRN) employing pulse sequences relatively insensitive to susceptibility artifacts (susceptibility insensitive MRN, siMRN) in a series of 9 patients with HRS procedure related sciatic nerve palsy. We were able to determine the localization and fascicular distribution of the sciatic nerve lesion in all 9 patients, which clearly showed on imaging predominant involvement of the peroneal more than the tibial division of the sciatic nerve. In 2 patients siMRN revealed direct mechanical compromise of the nerve by surgical material, and in one of these cases indication for surgical release of the sciatic nerve was based on siMRN. Thus, in selected cases of HRS related neuropathies, especially when surgical exploration of the nerve is considered, siMRN, with its potential to largely overcome implant related artifacts, is a useful diagnostic addition to nerve-conduction-studies and electromyography. PMID:24558483
Schwann cell glycogen selectively supports myelinated axon function.
Brown, Angus M; Evans, Richard D; Black, Joel; Ransom, Bruce R
2012-09-01
Interruption of energy supply to peripheral axons is a cause of axon loss. We determined whether glycogen was present in mammalian peripheral nerve, and whether it supported axon conduction during aglycemia. We used biochemical assay and electron microscopy to determine the presence of glycogen, and electrophysiology to monitor axon function. Glycogen was present in sciatic nerve, its concentration varying directly with ambient glucose. Electron microscopy detected glycogen granules primarily in myelinating Schwann cell cytoplasm, and these diminished after exposure to aglycemia. During aglycemia, conduction failure in large myelinated axons (A fibers) mirrored the time course of glycogen loss. Latency to compound action potential (CAP) failure was directly related to nerve glycogen content at aglycemia onset. Glycogen did not benefit the function of slow-conducting, small-diameter unmyelinated axons (C fibers) during aglycemia. Blocking glycogen breakdown pharmacologically accelerated CAP failure during aglycemia in A fibers, but not in C fibers. Lactate was as effective as glucose in supporting sciatic nerve function, and was continuously released into the extracellular space in the presence of glucose and fell rapidly during aglycemia. Our findings indicated that glycogen is present in peripheral nerve, primarily in myelinating Schwann cells, and exclusively supports large-diameter, myelinated axon conduction during aglycemia. Available evidence suggests that peripheral nerve glycogen breaks down during aglycemia and is passed, probably as lactate, to myelinated axons to support function. Unmyelinated axons are not protected by glycogen and are more vulnerable to dysfunction during periods of hypoglycemia. . Copyright © 2012 American Neurological Association.
Schwann Cell Glycogen Selectively Supports Myelinated Axon Function
Brown, Angus M; Evans, Richard D; Black, Joel; Ransom, Bruce R
2012-01-01
Objectives Interruption of energy supply to peripheral axons is a cause of axon loss. We determined if glycogen was present in mammalian peripheral nerve, and if it supported axon conduction during aglycemia. Methods We used biochemical assay and electron microscopy to determine the presence of glycogen, and electrophysiology to monitor axon function. Results Glycogen was present in sciatic nerve, its concentration varying directly with ambient [glucose]. Electron microscopy detected glycogen granules primarily in myelinating Schwann cell cytoplasm and these diminished after exposure to aglycemia. During aglycemia, conduction failure in large myelinated axons (A fibers) mirrored the time-course of glycogen loss. Latency to CAP failure was directly related to nerve glycogen content at aglycemia onset. Glycogen did not benefit the function of slow-conducting, small diameter unmyelinated axons (C fibers) during aglycemia. Blocking glycogen breakdown pharmacologically accelerated CAP failure during aglycemia in A fibers, but not in C fibers. Lactate was as effective as glucose in supporting sciatic nerve function, and was continuously released into the extracellular space in the presence of glucose and fell rapidly during aglycemia. Interpretation Our findings indicated that glycogen is present in peripheral nerve, primarily in myelinating Schwann cells, and exclusively supports large diameter, myelinated axon conduction during aglycemia. Available evidence suggests that peripheral nerve glycogen breaks down during aglycemia and is passed, probably as lactate, to myelinated axons to support function. Unmyelinated axons are not protected by glycogen and are more vulnerable to dysfunction during periods of hypoglycemia. PMID:23034913
Arm Nerve Conduction Velocity (NCV), Brain NCV, Reaction Time, and Intelligence.
ERIC Educational Resources Information Center
Reed, T. Edward; Jensen, Arthur R.
1991-01-01
Correlations among peripheral nerve conduction velocity (NCV), brain NCV, simple and choice reaction times, and a standard measure of intelligence were investigated for 200 male college students. No correlation was found between any arm NCV and the intelligence score. Neurophysiological bases of human information processing and intelligence are…
Intelligence, Reaction Times, and Peripheral Nerve Conduction Velocity.
ERIC Educational Resources Information Center
Vernon, Philip A.; Mori, Monica
1992-01-01
In 2 studies with 85 and 88 undergraduates, respectively, peripheral nerve conduction velocity (NCV) was significantly correlated with IQ score and reaction times, and NCV and reaction time contributed significantly, in combination, to prediction of IQ. Results are interpreted in terms of a neural efficiency model of intelligence. (Author/SLD)
Early identification of ‘acute-onset’ chronic inflammatory demyelinating polyneuropathy
Sung, Jia-Ying; Tani, Jowy; Park, Susanna B.; Kiernan, Matthew C.
2014-01-01
Distinguishing patients with acute-onset chronic inflammatory demyelinating polyneuropathy from acute inflammatory demyelinating polyneuropathy prior to relapse is often challenging at the onset of their clinical presentation. In the present study, nerve excitability tests were used in conjunction with the clinical phenotype and disease staging, to differentiate between patients with acute-onset chronic inflammatory demyelinating polyneuropathy and patients with acute inflammatory demyelinating polyneuropathy at an early stage, with the aim to better guide treatment. Clinical assessment, staging and nerve excitability tests were undertaken on patients initially fulfilling the diagnostic criteria of acute inflammatory demyelinating polyneuropathy soon after symptom onset and their initial presentation. Patients were subsequently followed up for minimum of 12 months to determine if their clinical presentations were more consistent with acute-onset chronic inflammatory demyelinating polyneuropathy. Clinical severity as evaluated by Medical Research Council sum score and Hughes functional grading scale were not significantly different between the two cohorts. There was no difference between the time of onset of initial symptoms and nerve excitability test assessment between the two cohorts nor were there significant differences in conventional nerve conduction study parameters. However, nerve excitability test profiles obtained from patients with acute inflammatory demyelinating polyneuropathy demonstrated abnormalities in the recovery cycle of excitability, including significantly reduced superexcitability (P < 0.001) and prolonged relative refractory period (P < 0.01), without changes in threshold electrotonus. In contrast, in patients with acute-onset chronic inflammatory demyelinating polyneuropathy, a different pattern occurred with the recovery cycle shifted downward (increased superexcitability, P < 0.05; decreased subexcitability, P < 0.05) and increased threshold change in threshold electrotonus in both hyperpolarizing and depolarizing directions [depolarizing threshold electrotonus (90–100 ms) P < 0.005, hyperpolarizing threshold electrotonus (10–20 ms), P < 0.01, hyperpolarizing threshold electrotonus (90–100 ms), P < 0.05], perhaps suggesting early hyperpolarization. In addition, using excitability parameters superexcitability, subexcitability and hyperpolarizing threshold electrotonus (10–20 ms), the patients with acute inflammatory demyelinating polyneuropathy and acute-onset chronic inflammatory demyelinating polyneuropathy could be clearly separated into two non-overlapping groups. Studies of nerve excitability may be able to differentiate acute from acute-onset chronic inflammatory demyelinating polyneuropathy at an early stage. Characteristic nerve excitability parameter changes occur in early acute-onset chronic inflammatory demyelinating polyneuropathy, to match the clinical phenotype. Importantly, this pattern of change was strikingly different to that shown by patients with acute inflammatory demyelinating polyneuropathy, suggesting that nerve excitability techniques may be useful in distinguishing acute-onset chronic inflammatory demyelinating polyneuropathy from acute inflammatory demyelinating polyneuropathy at the initial stage. PMID:24983276
Wolny, Tomasz; Saulicz, Edward; Linek, Paweł; Shacklock, Michael; Myśliwiec, Andrzej
2017-05-01
The purpose of this randomized trial was to compare the efficacy of manual therapy, including the use of neurodynamic techniques, with electrophysical modalities on patients with mild and moderate carpal tunnel syndrome (CTS). The study included 140 CTS patients who were randomly assigned to the manual therapy (MT) group, which included the use of neurodynamic techniques, functional massage, and carpal bone mobilizations techniques, or to the electrophysical modalities (EM) group, which included laser and ultrasound therapy. Nerve conduction, pain severity, symptom severity, and functional status measured by the Boston Carpal Tunnel Questionnaire were assessed before and after treatment. Therapy was conducted twice weekly and both groups received 20 therapy sessions. A baseline assessment revealed group differences in sensory conduction of the median nerve (P < .01) but not in motor conduction (P = .82). Four weeks after the last treatment procedure, nerve conduction was examined again. In the MT group, median nerve sensory conduction velocity increased by 34% and motor conduction velocity by 6% (in both cases, P < .01). There was no change in median nerve sensory and motor conduction velocities in the EM. Distal motor latency was decreased (P < .01) in both groups. A baseline assessment revealed no group differences in pain severity, symptom severity, or functional status. Immediately after therapy, analysis of variance revealed group differences in pain severity (P < .01), with a reduction in pain in both groups (MT: 290%, P < .01; EM: 47%, P < .01). There were group differences in symptom severity (P < .01) and function (P < .01) on the Boston Carpal Tunnel Questionnaire. Both groups had an improvement in functional status (MT: 47%, P < .01; EM: 9%, P < .01) and a reduction in subjective CTS symptoms (MT: 67%, P < .01; EM: 15%, P < .01). Both therapies had a positive effect on nerve conduction, pain reduction, functional status, and subjective symptoms in individuals with CTS. However, the results regarding pain reduction, subjective symptoms, and functional status were better in the MT group. Copyright © 2017. Published by Elsevier Inc.
Clinical and electrodiagnostic characteristics of nitrous oxide-induced neuropathy in Taiwan.
Li, Han-Tao; Chu, Chun-Che; Chang, Kuo-Hsuan; Liao, Ming-Feng; Chang, Hong-Shiu; Kuo, Hung-Chou; Lyu, Rong-Kuo
2016-10-01
Nitrous oxide-induced neuropathy is toxic neuropathy occasionally encountered in Taiwanese neurological clinics. Only several case reports described their electrodiagnostic features. We used a case-control design to investigate the detailed electrodiagnostic characteristics and possible factors relating to severe nerve injury. We retrospectively reviewed 33 patients with nitrous oxide-induced neuropathy over a 10-year period and reported their demographic data, spinal cord MRI, laboratory examinations and nerve conduction studies. 56 healthy controls' nerve conduction studies were collected for comparison analysis. We noted significant motor and sensory amplitudes reduction, conduction velocities slowing, and latencies prolongation in most tested nerves compared to the controls. Similar nerve conduction study characteristics with prominent lower limbs' motor and sensory amplitudes reduction was observed in patient groups with or without abnormal vitamin B12 and/or homocysteine levels. Among those with lower limbs' motor or sensory amplitudes reduction <20% of the lower limit of normal, higher homocysteine levels were detected. Severe impairments of the lower limbs' sensory and motor amplitudes were frequently noted in patients with nitrous oxide exposure. Nitrous oxide exposure itself is an important factor for the development of neuropathy. Our study contributes to the understanding of electrodiagnostic features underlying the nitrous oxide-induced neuropathy. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Alrawashdeh, Omar; Alsbou, Mohammad; Alzoubi, Hamed; Al-Shagahin, Hani
2016-11-02
Alkaptonuria is a rare metabolic disease characterised by accumulative deposition of homogentisic acid in the connective tissue of the body. This results in early degeneration of tendons, cartilages, heart valves, and other tissues. The main objective of the study is to examine the possibility of the nervous system involvement in patients with alkaptonuria The sample consists of two groups; 22 patients with AKU and 20 controls. A neurological assessment has been carried out including detailed medical history, neurological examination, and a nerve conduction study of the nerves of the dominant hand. The prevalence of any abnormality was compared between the two groups using chi square test. The mean values of the nerve conduction study were compared between the two groups using student t-test. There was a higher prevalence of low back pain, hearing problems and tinnitus, numbness and neuropathic pain in alkaptonuria patients. There was no significant difference between the two groups in other conditions such as seizures, headache, and syncope. The values of the nerve conduction study did not show significant difference between the two groups. Neurologically related symptoms in alkaptonuria mostly represent complications of the connective tissue degeneration rather than direct involvement of the nervous system. This has been supported further by the normal findings of the neurophysiology study in patients with alkaptonuria.
Temporary Mental Nerve Paresthesia Originating from Periapical Infection
Genc Sen, Ozgur; Kaplan, Volkan
2015-01-01
Many systemic and local factors can cause paresthesia, and it is rarely caused by infections of dental origin. This report presents a case of mental nerve paresthesia caused by endodontic infection of a mandibular left second premolar. Resolution of the paresthesia began two weeks after conventional root canal treatment associated with antibiotic therapy and was completed in eight weeks. One year follow-up radiograph indicated complete healing of the radiolucent periapical lesion. The tooth was asymptomatic and functional. PMID:26345692
Modeling the response of small myelinated axons in a compound nerve to kilohertz frequency signals
NASA Astrophysics Data System (ADS)
Pelot, N. A.; Behrend, C. E.; Grill, W. M.
2017-08-01
Objective. There is growing interest in electrical neuromodulation of peripheral nerves, particularly autonomic nerves, to treat various diseases. Electrical signals in the kilohertz frequency (KHF) range can produce different responses, including conduction block. For example, EnteroMedics’ vBloc® therapy for obesity delivers 5 kHz stimulation to block the abdominal vagus nerves, but the mechanisms of action are unclear. Approach. We developed a two-part computational model, coupling a 3D finite element model of a cuff electrode around the human abdominal vagus nerve with biophysically-realistic electrical circuit equivalent (cable) model axons (1, 2, and 5.7 µm in diameter). We developed an automated algorithm to classify conduction responses as subthreshold (transmission), KHF-evoked activity (excitation), or block. We quantified neural responses across kilohertz frequencies (5-20 kHz), amplitudes (1-8 mA), and electrode designs. Main results. We found heterogeneous conduction responses across the modeled nerve trunk, both for a given parameter set and across parameter sets, although most suprathreshold responses were excitation, rather than block. The firing patterns were irregular near transmission and block boundaries, but otherwise regular, and mean firing rates varied with electrode-fibre distance. Further, we identified excitation responses at amplitudes above block threshold, termed ‘re-excitation’, arising from action potentials initiated at virtual cathodes. Excitation and block thresholds decreased with smaller electrode-fibre distances, larger fibre diameters, and lower kilohertz frequencies. A point source model predicted a larger fraction of blocked fibres and greater change of threshold with distance as compared to the realistic cuff and nerve model. Significance. Our findings of widespread asynchronous KHF-evoked activity suggest that conduction block in the abdominal vagus nerves is unlikely with current clinical parameters. Our results indicate that compound neural or downstream muscle force recordings may be unreliable as quantitative measures of neural activity for in vivo studies or as biomarkers in closed-loop clinical devices.
Modeling the response of small myelinated axons in a compound nerve to kilohertz frequency signals.
Pelot, N A; Behrend, C E; Grill, W M
2017-08-01
There is growing interest in electrical neuromodulation of peripheral nerves, particularly autonomic nerves, to treat various diseases. Electrical signals in the kilohertz frequency (KHF) range can produce different responses, including conduction block. For example, EnteroMedics' vBloc ® therapy for obesity delivers 5 kHz stimulation to block the abdominal vagus nerves, but the mechanisms of action are unclear. We developed a two-part computational model, coupling a 3D finite element model of a cuff electrode around the human abdominal vagus nerve with biophysically-realistic electrical circuit equivalent (cable) model axons (1, 2, and 5.7 µm in diameter). We developed an automated algorithm to classify conduction responses as subthreshold (transmission), KHF-evoked activity (excitation), or block. We quantified neural responses across kilohertz frequencies (5-20 kHz), amplitudes (1-8 mA), and electrode designs. We found heterogeneous conduction responses across the modeled nerve trunk, both for a given parameter set and across parameter sets, although most suprathreshold responses were excitation, rather than block. The firing patterns were irregular near transmission and block boundaries, but otherwise regular, and mean firing rates varied with electrode-fibre distance. Further, we identified excitation responses at amplitudes above block threshold, termed 're-excitation', arising from action potentials initiated at virtual cathodes. Excitation and block thresholds decreased with smaller electrode-fibre distances, larger fibre diameters, and lower kilohertz frequencies. A point source model predicted a larger fraction of blocked fibres and greater change of threshold with distance as compared to the realistic cuff and nerve model. Our findings of widespread asynchronous KHF-evoked activity suggest that conduction block in the abdominal vagus nerves is unlikely with current clinical parameters. Our results indicate that compound neural or downstream muscle force recordings may be unreliable as quantitative measures of neural activity for in vivo studies or as biomarkers in closed-loop clinical devices.
Influence of limb temperature on cutaneous silent periods.
Kofler, Markus; Valls-Solé, Josep; Vasko, Peter; Boček, Václav; Štetkárová, Ivana
2014-09-01
The cutaneous silent period (CSP) is a spinal inhibitory reflex mediated by small-diameter afferents (A-delta fibers) and large-diameter efferents (alpha motoneurons). The effect of limb temperature on CSPs has so far not been assessed. In 27 healthy volunteers (11 males; age 22-58 years) we recorded median nerve motor and sensory action potentials, median nerve F-wave and CSPs induced by noxious digit II stimulation in thenar muscles in a baseline condition at room temperature, and after randomly submersing the forearm in 42 °C warm or 15 °C cold water for 20 min each. In cold limbs, distal and proximal motor and sensory latencies as well as F-wave latencies were prolonged. Motor and sensory nerve conduction velocities were reduced. Compound motor and sensory nerve action potential amplitudes did not differ significantly from baseline. CSP onset and end latencies were more delayed than distal and proximal median nerve motor and sensory latencies, whereas CSP duration was not affected. In warm limbs, opposite but smaller changes were seen in nerve conduction studies and CSPs. The observed CSP shift "en bloc" towards longer latencies without affecting CSP duration during limb cooling concurs with slower conduction velocity in both afferent and efferent fibers. Disparate conduction slowing in afferents and efferents, however, suggests that nociceptive EMG suppression is mediated by fibers of different size in the afferent than in the efferent arm, indirectly supporting the contribution of A-delta fibers as the main afferent input. Limb temperature should be taken into account when testing CSPs in the clinical setting, as different limb temperatures affect CSP latencies more than large-diameter fiber conduction function. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Development of ocular viscosity characterization method.
Shu-Hao Lu; Guo-Zhen Chen; Leung, Stanley Y Y; Lam, David C C
2016-08-01
Glaucoma is the second leading cause for blindness. Irreversible and progressive optic nerve damage results when the intraocular pressure (IOP) exceeds 21 mmHg. The elevated IOP is attributed to blocked fluid drainage from the eye. Methods to measure the IOP are widely available, but methods to measure the viscous response to blocked drainage has yet been developed. An indentation method to characterize the ocular flow is developed in this study. Analysis of the load-relaxation data from indentation tests on drainage-controlled porcine eyes showed that the blocked drainage is correlated with increases in ocular viscosity. Successful correlation of the ocular viscosity with drainage suggests that ocular viscosity maybe further developed as a new diagnostic parameter for assessment of normal tension glaucoma where nerve damage occurs without noticeable IOP elevation; and as a diagnostic parameter complimentary to conventional IOP in conventional diagnosis.
Chronic nerve compression alters Schwann cell myelin architecture in a murine model
Gupta, Ranjan; Nassiri, Nima; Hazel, Antony; Bathen, Mary; Mozaffar, Tahseen
2011-01-01
Introduction Myelinating Schwann cells compartmentalize their outermost layer to form actin-rich channels known as Cajal bands. Here, we investigate changes in Schwann cell architecture and cytoplasmic morphology in a novel mouse model of carpal tunnel syndrome. Methods Chronic nerve compression (CNC) injury was created in wild-type and slow-Wallerian degeneration (WldS) mice. Over 12 weeks, nerves were electrodiagnostically assessed, and Schwann cell morphology was thoroughly evaluated. Results A decline in nerve conduction velocity and increase in g-ratio is observed without early axonal damage. Schwann cells display shortened internodal lengths and severely disrupted Cajal bands. Quite surprisingly, the latter is reconstituted without improvements to nerve conduction velocity. Discussion Chronic entrapment injuries like carpal tunnel syndrome are primarily mediated by the Schwann cell response, wherein decreases in internodal length and myelin thickness disrupt the efficiency of impulse propagation. Restitution of Cajal bands is not sufficient for remyelination post-CNC injury. PMID:22246880
Neuropathic symptoms and findings in women with Fabry disease.
Laaksonen, Satu M; Röyttä, Matias; Jääskeläinen, Satu K; Kantola, Ilkka; Penttinen, Maila; Falck, Björn
2008-06-01
To examine the neurologic and neurophysiologic findings and neurologic symptoms in 12 women with Fabry disease and to study the relationship between the subjective symptoms and the findings on the various tests done. Neurography, vibratory and thermal quantitative sensory testing (QST), skin biopsy for measuring intraepidermal nerve fiber density (IENFD). Heart rate variability (HRV) and sympathetic skin response (SSR) tests for detecting autonomic dysfunction, pain-, depression- and somatic symptom questionnaires and clinical examination. Only two women had no persistent symptoms or signs of polyneuropathy, 10 had symptoms of small fiber neuropathy. Neurological examination was normal in most patients. Five patients had decreased IENFD or thermal hypoesthesia in QST. In QST, Adelta-fiber function for innocuous cold was more often impaired than C-fiber function. Conventional nerve conduction studies were mostly normal. Carpal tunnel syndrome (CTS) incidence was increased, 25% had symptomatic CTS. Heterozygous women carrying the gene for Fabry disease have symptoms and findings of small-fiber polyneuropathy more often than has previously been considered. The prevalence of CTS is also increased. While the clinical diagnosis of small-fiber neuropathy is difficult, the diagnostic yield can be increased using a combination of thermal QST and IENFD measurements.
Bernardo, Antonio; Evins, Alexander I; Visca, Anna; Stieg, Phillip E
2013-06-01
The facial nerve has a short intracranial course but crosses critical and frequently accessed surgical structures during cranial base surgery. When performing approaches to complex intracranial regions, it is essential to understand the nerve's conventional and topographic anatomy from different surgical perspectives as well as its relationship with surrounding structures. To describe the entire intracranial course of the facial nerve as observed via different neurosurgical approaches and to provide an analytical evaluation of the degree of nerve exposure achieved with each approach. Anterior petrosectomies (middle fossa, extended middle fossa), posterior petrosectomies (translabyrinthine, retrolabyrinthine, transcochlear), a retrosigmoid, a far lateral, and anterior transfacial (extended maxillectomy, mandibular swing) approaches were performed on 10 adult cadaveric heads (20 sides). The degree of facial nerve exposure achieved per segment for each approach was assessed and graded independently by 3 surgeons. The anterior petrosal approaches offered good visualization of the nerve in the cerebellopontine angle and intracanalicular portion superiorly, whereas the posterior petrosectomies provided more direct visualization without the need for cerebellar retraction. The far lateral approach exposed part of the posterior and the entire inferior quadrants, whereas the retrosigmoid approach exposed parts of the superior and inferior quadrants and the entire posterior quadrant. Anterior and anteroinferior exposure of the facial nerve was achieved via the transfacial approaches. The surgical route used must rely on the size, nature, and general location of the lesion, as well as on the capability of the particular approach to better expose the appropriate segment of the facial nerve.
Rabischong, B; Botchorishvili, R; Bourdel, N; Curinier, S; Campagne-Loiseau, S; Pouly, J L; Canis, M
2018-03-01
To evaluate the feasibility and functional urinary and digestive results of nerve sparing techniques in endometriosis surgery. A research on the medline/pubmed database using specific keywords (nerve sparing, endometriosis, pelvic nerves) identified 7 publications among about 50 whose purpose was to describe the feasibility, the techniques and the functional results of nerve preservation in this indication. Among them there are: 2 uncontrolled retrospective studies, 3 prospective non-randomized studies, a meta-analysis and a review of the literature. Nerve preservation requires a perfect knowledge of the anatomy of the pelvic autonomic system. The laparoscopic approach is preferred by the different authors due to its anatomical advantage. The feasibility of this technique seems to be demonstrated despite certain limitations in the different studies and depending of the retroperitoneal extension of the lesions. When feasible, it is likely to significantly improve postoperative urinary function (urinary retention) compared to a conventional technique. It is observed no difference regarding digestive function. Nerve sparing in this indication is a technique the feasibility of which has been demonstrated and is subject to the topography and extent of the disease. In the absence of invasion or entrapment of pelvic autonomic nerves by endometriosis, this technique improves postoperative voiding function (NP3). During pelvic surgery for endometriosis, it is recommended to identify and preserve autonomic pelvic nerves whenever possible (GradeC). Copyright © 2018. Published by Elsevier Masson SAS.
Rewiring the primary somatosensory cortex in carpal tunnel syndrome with acupuncture
Maeda, Yumi; Kim, Hyungjun; Kettner, Norman; Kim, Jieun; Cina, Stephen; Malatesta, Cristina; Gerber, Jessica; McManus, Claire; Ong-Sutherland, Rebecca; Mezzacappa, Pia; Libby, Alexandra; Mawla, Ishtiaq; Morse, Leslie R.; Kaptchuk, Ted J.; Audette, Joseph
2017-01-01
Abstract Carpal tunnel syndrome is the most common entrapment neuropathy, affecting the median nerve at the wrist. Acupuncture is a minimally-invasive and conservative therapeutic option, and while rooted in a complex practice ritual, acupuncture overlaps significantly with many conventional peripherally-focused neuromodulatory therapies. However, the neurophysiological mechanisms by which acupuncture impacts accepted subjective/psychological and objective/physiological outcomes are not well understood. Eligible patients (n = 80, 65 female, age: 49.3 ± 8.6 years) were enrolled and randomized into three intervention arms: (i) verum electro-acupuncture ‘local’ to the more affected hand; (ii) verum electro-acupuncture at ‘distal’ body sites, near the ankle contralesional to the more affected hand; and (iii) local sham electro-acupuncture using non-penetrating placebo needles. Acupuncture therapy was provided for 16 sessions over 8 weeks. Boston Carpal Tunnel Syndrome Questionnaire assessed pain and paraesthesia symptoms at baseline, following therapy and at 3-month follow-up. Nerve conduction studies assessing median nerve sensory latency and brain imaging data were acquired at baseline and following therapy. Functional magnetic resonance imaging assessed somatotopy in the primary somatosensory cortex using vibrotactile stimulation over three digits (2, 3 and 5). While all three acupuncture interventions reduced symptom severity, verum (local and distal) acupuncture was superior to sham in producing improvements in neurophysiological outcomes, both local to the wrist (i.e. median sensory nerve conduction latency) and in the brain (i.e. digit 2/3 cortical separation distance). Moreover, greater improvement in second/third interdigit cortical separation distance following verum acupuncture predicted sustained improvements in symptom severity at 3-month follow-up. We further explored potential differential mechanisms of local versus distal acupuncture using diffusion tensor imaging of white matter microstructure adjacent to the primary somatosensory cortex. Compared to healthy adults (n = 34, 28 female, 49.7 ± 9.9 years old), patients with carpal tunnel syndrome demonstrated increased fractional anisotropy in several regions and, for these regions we found that improvement in median nerve latency was associated with reduction of fractional anisotropy near (i) contralesional hand area following verum, but not sham, acupuncture; (ii) ipsilesional hand area following local, but not distal or sham, acupuncture; and (iii) ipsilesional leg area following distal, but not local or sham, acupuncture. As these primary somatosensory cortex subregions are distinctly targeted by local versus distal acupuncture electrostimulation, acupuncture at local versus distal sites may improve median nerve function at the wrist by somatotopically distinct neuroplasticity in the primary somatosensory cortex following therapy. Our study further suggests that improvements in primary somatosensory cortex somatotopy can predict long-term clinical outcomes for carpal tunnel syndrome. PMID:28334999
NASA Astrophysics Data System (ADS)
Torres, Veronica C.; Vuong, Victoria D.; Wilson, Todd; Wewel, Joshua; Byrne, Richard W.; Tichauer, Kenneth M.
2017-09-01
Nerve preservation during surgery is critical because damage can result in significant morbidity. This remains a challenge especially for skull base surgeries where cranial nerves (CNs) are involved because visualization and access are particularly poor in that location. We present a paired-agent imaging method to enhance identification of CNs using nerve-specific fluorophores. Two myelin-targeting imaging agents were evaluated, Oxazine 4 and Rhodamine 800, and coadministered with a control agent, indocyanine green, either intravenously or topically in rats. Fluorescence imaging was performed on excised brains ex vivo, and nerve contrast was evaluated via paired-agent ratiometric data analysis. Although contrast was improved among all experimental groups using paired-agent imaging compared to conventional, solely targeted imaging, Oxazine 4 applied directly exhibited the greatest enhancement, with a minimum 3 times improvement in CNs delineation. This work highlights the importance of accounting for nonspecific signal of targeted agents, and demonstrates that paired-agent imaging is one method capable of doing so. Although staining, rinsing, and imaging protocols need to be optimized, these findings serve as a demonstration for the potential use of paired-agent imaging to improve contrast of CNs, and consequently, surgical outcome.
Wang, Zhi-Yong; Wang, Jian-Wei; Qin, Li-Hua; Zhang, Wei-Guang; Zhang, Pei-Xun; Jiang, Bao-Guo
2018-06-01
To investigate the efficacy of chitin biological absorbable catheters in a rat model of autologous nerve transplantation. A segment of sciatic nerve was removed to produce a sciatic nerve defect, and the sural nerve was cut from the ipsilateral leg and used as a graft to bridge the defect, with or without use of a chitin biological absorbable catheter surrounding the graft. The number and morphology of regenerating myelinated fibers, nerve conduction velocity, nerve function index, triceps surae muscle morphology, and sensory function were evaluated at 9 and 12 months after surgery. All of the above parameters were improved in rats in which the nerve graft was bridged with chitin biological absorbable catheters compared with rats without catheters. The results of this study indicate that use of chitin biological absorbable catheters to surround sural nerve grafts bridging sciatic nerve defects promotes recovery of structural, motor, and sensory function and improves muscle fiber morphology. © 2018 John Wiley & Sons Ltd.
ERIC Educational Resources Information Center
Reed, T. Edward
1993-01-01
Results with 54 mice confirm that increased stimulation or usage, as would be provided by environmental enrichment (EE), increases peripheral nerve conduction velocity. These results suggest a role at the physiological level for EE (or deprivation) in affecting measured intelligence. (SLD)
Conduction studies of the normal sural nerve.
Horowitz, S H; Krarup, C
1992-03-01
The sural nerve was studied orthodromically using the near-nerve technique in 273 normal subjects (155 females, 118 males) aged 5 to 90 years. The sensory action potential (SAP), evoked at the dorsum of the foot, was recorded at the lateral malleolus and midcalf, and at the midcalf when evoked at the lateral malleolus. In addition, the SAP was recorded at intermediate distal sites and at proximal sites at the popliteal fossa, the gluteal fold, and the S-1 root. The amplitude of the SAP recorded at midcalf was 32% higher in females than in males. This was probably due to volume-conduction properties, as differences between genders were less noticeable at more distal recording sites. The amplitude decreased steeply and exponentially with age. Conduction distance had a strong influence on the amplitude of the SAP, which decreased with increasing distance following a power relationship with an exponent of 1.4 to 1.7. This decrease was due to temporal dispersion with decreased summation and increased phase cancellation. The conduction velocity was slightly lower along the very distal course of the nerve than along more proximal segments.
Yorek, Matthew S.; Obrosov, Alexander; Shevalye, Hanna; Holmes, Amey; Harper, Matthew M.; Kardon, Randy H.; Yorek, Mark A.
2015-01-01
We determined the impact diet induced obesity (DIO) and types 1 and 2 diabetes has on peripheral neuropathy with emphasis on corneal nerve structural changes in C57Bl/6J mice. Endpoints examined included nerve conduction velocity, response to thermal and mechanical stimuli and innervation of the skin and cornea. DIO mice and to a greater extent type 2 diabetic mice were insulin resistant. DIO and both types 1 and 2 diabetic mice developed motor and sensory nerve conduction deficits. In the cornea of DIO and type 2 diabetic mice there was a decrease in sub-epithelial corneal nerves, innervation of the corneal epithelium and corneal sensitivity. Type 1 diabetic mice did not present with any significant changes in corneal nerve structure until after 20 weeks of hyperglycemia. DIO and type 2 diabetic mice developed corneal structural damage more rapidly than type 1 diabetic mice even though hemoglobin A1C values were significantly higher in type 1 diabetic mice. This suggests that DIO with or without hyperglycemia contributes to development and progression of peripheral neuropathy and nerve structural damage in the cornea. PMID:25858759
Comparison of four different nerve conduction techniques of the superficial fibular sensory nerve.
Saffarian, Mathew R; Condie, Nathan C; Austin, Erica A; Mccausland, Katie E; Andary, Michael T; Sylvain, James R; Mull, Iian R; Zemper, Eric D; Jannausch, Mary L
2017-09-01
There are many different nerve conduction study (NCS) techniques to study the superficial fibular sensory nerve (SFSN). We present reference distal latency values and comparative data regarding 4 different NCS for the SFSN. Four different NCS techniques, Spartan technique, Izzo techniques (medial and intermediate dorsal cutaneous branches), and Daube technique, were performed on (114) healthy volunteers. A total of 108 subjects with 164 legs were included. The mean latency of the Spartan technique was longest (3.9 ± 0.3 ms) while the Daube technique was the shortest (3.6 ± 0.7 ms). The mean amplitude of the Daube technique displayed the highest (15.2 ± 8.2 μV) with the Spartan technique having the lowest (8.7 ± 4.2 μV). Among the absent sensory nerve action potentials (SNAPs), the Spartan technique was absent only twice (1.2%) and the Izzo Medial technique was absent more than the other techniques (2.9%). All 4 techniques were reliable methods for obtaining the superficial fibular nerve SNAP, present in 95% of individuals. Muscle Nerve 56: 458-462, 2017. © 2017 Wiley Periodicals, Inc.
A novel method for measuring hydraulic conductivity at the human blood-nerve barrier in vitro.
Helton, E Scott; Palladino, Steven; Ubogu, Eroboghene E
2017-01-01
Microvascular barrier permeability to water is an essential biophysical property required for the homeostatic maintenance of unique tissue microenvironments. This is of particular importance in peripheral nerves where strict control of ionic concentrations is needed for axonal signal transduction. Previous studies have associated inflammation, trauma, toxin exposure and metabolic disease with increases in water influx and hydrostatic pressure in peripheral nerves with resultant endoneurial edema that may impair axonal function. The regulation of water permeability across endoneurial microvessels that form the blood-nerve barrier (BNB) is poorly understood. Variations exist in apparatus and methods used to measure hydraulic conductivity. The objective of the study was to develop a simplified hydraulic conductivity system using commercially available components to evaluate the BNB. We determined the mean hydraulic conductivity of cultured confluent primary and immortalized human endoneurial endothelial cell layers as 2.00×10 -7 and 2.17×10 -7 cm/s/cm H₂O respectively, consistent with restrictive microvascular endothelial cells in vitro. We also determined the mean hydraulic conductivity of immortalized human brain microvascular endothelial cell layers, a commonly used blood-brain barrier (BBB) cell line, as 0.20×10 -7 cm/s/cm H₂O, implying a mean 10-fold higher resistance to transendothelial water flux in the brain compared to peripheral nerves. To our knowledge, this is the first reported measurement of human BNB and BBB hydraulic conductivities. This model represents an important tool to further characterize the human BNB and deduce the molecular determinants and signaling mechanisms responsible for BNB hydraulic conductivity in normal and disease states in vitro. Copyright © 2016 Elsevier Inc. All rights reserved.
Evanoff, Bradley; Kymes, Steve
2010-06-01
The aim of this study was to evaluate the costs associated with pre-employment nerve conduction testing as a screening tool for carpal tunnel syndrome (CTS) in the workplace. We used a Markov decision analysis model to compare the costs associated with a strategy of screening all prospective employees for CTS and not hiring those with abnormal nerve conduction, versus a strategy of not screening for CTS. The variables included in our model included employee turnover rate, the incidence of CTS, the prevalence of median nerve conduction abnormalities, the relative risk of developing CTS conferred by abnormal nerve conduction screening, the costs of pre-employment screening, and the worker's compensation costs to the employer for each case of CTS. In our base case, total employer costs for CTS from the perspective of the employer (cost of screening plus costs for workers' compensation associated with CTS) were higher when screening was used. Median costs per employee position over five years were US$503 for the screening strategy versus US$200 for a no-screening strategy. A sensitivity analysis showed that a strategy of screening was cost-beneficial from the perspective of the employer only under a few circumstances. Using Monte Carlo simulation varying all parameters, we found a 30% probability that screening would be cost-beneficial. A strategy of pre-employment screening for CTS should be carefully evaluated for yield and social consequences before being implemented. Our model suggests such screening is not appropriate for most employers.
Arched needle technique for inferior alveolar mandibular nerve block.
Chakranarayan, Ashish; Mukherjee, B
2013-03-01
One of the most commonly used local anesthetic techniques in dentistry is the Fischer's technique for the inferior alveolar nerve block. Incidentally this technique also suffers the maximum failure rate of approximately 35-45%. We studied a method of inferior alveolar nerve block by injecting a local anesthetic solution into the pterygomandibular space by arching and changing the approach angle of the conventional technique and estimated its efficacy. The needle after the initial insertion is arched and inserted in a manner that it approaches the medial surface of the ramus at an angle almost perpendicular to it. The technique was applied to 100 patients for mandibular molar extraction and the anesthetic effects were assessed. A success rate of 98% was obtained.
Pan, Xiao-Jie; Ou, De-Bin; Lin, Xing; Ye, Ming-Fang
2017-06-01
Residual air space problems after pulmonary lobectomy are an important concern in thoracic surgical practice, and various procedures have been applied to manage them. This study describes a novel technique using controllable paralysis of the diaphragm by localized freezing of the phrenic nerve, and assesses the effectiveness of this procedure to reduce air space after pulmonary lobectomy. In this prospective randomized study, 207 patients who underwent lobectomy or bilobectomy and systematic mediastinal node dissection in our department between January 2009 and November 2013 were randomly allocated to a cryoneuroablation group or a conventional group. Patients in the cryoneuroablation group (n = 104) received phrenic nerve cryoneuroablation after lung procedures, and patients in the conventional group (n = 103) did not receive cryoneuroablation after the procedure. Data regarding preoperative clinical and surgical characteristics in both groups were collected. Both groups were compared with regard to postoperative parameters such as total amount of pleural drainage, duration of chest tube placement, length of hospital stay, requirement for repeat chest drain insertion, prolonged air leak, and residual space. Perioperative lung function was also compared in both groups. Recovery of diaphragmatic movement in the cryoneuroablation group was checked by fluoroscopy on the 15th, 30th, and 60th day after surgery. There was no statistically significant difference in patient characteristics between the 2 groups; nor was there a difference in terms of hospital stay, new drain requirement, and incidence of empyema. In comparison with the conventional group, the cryoneuroablation group had less total drainage (1024 ± 562 vs 1520 ± 631 mL, P < .05), fewer cases of residual space (9 vs 2, P < .05), fewer cases of prolonged air leak (9 vs 1, P < .01), and shorter duration of drainage (3.2 ± 0.2 vs 4.3 + 0.3 days, P < .01). Diaphragmatic paralyses caused by cryoneuroablation reversed within 30 to 60 days. Cryoneuroablation of the phrenic nerve offers a reasonable option for prevention of residual air space following major pulmonary resection.
Al-Bustani, Najwa; Weiss, Michael D
2015-09-01
Chronic inflammatory demyelinating polyneuropathy (CIDP) is an immune-mediated sensory and motor demyelinating polyneuropathy that typically presents as a relapsing-remitting or progressive disorder. Cranial neuropathies infrequently occur in association with other more typical symptoms of CIDP. We report a case of CIDP with recurrent isolated sixth nerve palsy. Her physical examination showed a right sixth nerve palsy and absent deep tendon reflexes as the only indicator of her disease. Magnetic resonance imaging revealed thickening without enhancement of the trigeminal and sixth cranial nerves. Nerve conduction study (NCS) revealed a sensory and motor demyelinating polyneuropathy with conduction block and temporal dispersion in multiple nerves consistent with CIDP. Cerebrospinal fluid demonstrated albuminic-cytologic dissociation. She had a remarkable response to intravenous immunoglobulin and remains asymptomatic without any additional immunomodulating therapy. Isolated cranial neuropathies can rarely occur as the sole manifestation of relapsing-remitting CIDP. The profound demyelination found on NCS in this case demonstrates that there can be a dramatic discordance between the clinical and electrodiagnostic findings in some patients with this disorder.
Aras, Yeşim Güzey; Aydemir, Yusuf; Güngen, Belma Doğan; Güngen, Adil Can
2018-01-01
The aim of the study was to investigate the frequency and characteristics of peripheral nervous system (PNS) and central nervous system (CNS) involvement in COPD. The study included 41 COPD patients and 41 healthy volunteers. Electrophysiological studies were carried out: electromyography (EMG) and visual evoked potentials (VEPs). The median nerve, ulnar nerve, common peroneal nerve, and tibial nerve were evaluated for latency, amplitude, and conduction velocity. The mean age of patients with COPD was 61.8 years and disease duration 10.3 years. There was no difference between patient and control groups in terms of age, BMI, smoking status, or biochemical parameters. Upon VEP examination, latencies were significantly prolonged and amplitudes shortened in the patient group compared to the control group. In EMG measurements, conduction velocity and amplitudes in all nerves were low in the patient group. Similarly, latencies in all nerves were higher in patients with COPD. Central and peripheral nervous system involvement could develop in patients with moderate-severe COPD, and these patients should be monitored for neuropathic changes in combination with neurological examination.
NASA Astrophysics Data System (ADS)
Schmid, Gernot; Cecil, Stefan; Überbacher, Richard
2013-07-01
Based on numerical computations using commercially available finite difference time domain code and a state-of-the art anatomical model of a 5-year old child, the influence of skin conductivity on the induced electric field strength inside the tissue for homogeneous front-to-back magnetic field exposure and homogeneous vertical electric field exposure was computed. Both ungrounded as well as grounded conditions of the body model were considered. For electric field strengths induced inside CNS tissue the impact of skin conductivity was found to be less than 15%. However, the results demonstrated that the use of skin conductivity values as obtainable from the most widely used data base of dielectric tissue properties and recommended by safety standards are not suitable for exposure assessment with respect to peripheral nerve tissue according to the ICNIRP 2010 guidelines in which the use of the induced electric field strengths inside the skin is suggested as a conservative surrogate for peripheral nerve exposure. This is due to the fact that the skin conductivity values derived from these data bases refer to the stratum corneum, the uppermost layer of the skin, which does not contain any nerve or receptor cells to be protected from stimulation effects. Using these skin conductivity values which are approximately a factor 250-500 lower than skin conductivity values used in studies on which the ICNIRP 2010 guidelines are based on, may lead to overestimations of the induced electric field strengths inside the skin by substantially more than a factor of 10. However, reliable conductivity data of deeper skin layers where nerve and preceptor cells are located is very limited. It is therefore recommended to include appropriate background information in the ICNIRP guidelines and the dielectric tissue property databases, and to put some emphasis on a detailed layer-specific characterization of skin conductivity in near future.
[Chronic inflammatory demyelinating polyneuropathy. Findings in 30 patients].
Villa, A M; Molina, H; Sanz, O P; Sica, R E
1999-01-01
Chronic demyelinating inflammatory polineuropathy (CIDP) is a disease which was recognized several years ago. However, the mechanism underlying its pathogenesis remains poorly understood. Nevertheless, there are some clues which strongly suggest that it constitutes an autoimmune disease. Since 1992 we have studied 30 cases. All them were clinically assessed and submitted to laboratory investigations encompassing nerve conduction studies, sera proteins immunoelectrophoresis, spinal fluid analysis and sural nerve biopsies. Upon clinical examination the usual findings were weakness, muscle atrophy, absence or diminished tendon jerks, paresthesias and hyposthesias. Electrophysiological studies disclosed marked slowing of the nerve conduction velocities, suggesting demyelination. Sera immunoelectrophoresis detected monoclonal gammopathy in 17% of the studied patients, which was not associated with lymphoproliferative illnesses. Of the patients 79% had increased levels of spinal fluid proteins. Seventeen patients gave their consent for performing a sural nerve biopsy; all the samples showed demyelination. In conclusion, we think that CDIP is a disease which can be recognized when the clinical assessment, the nerve conduction studies and the spinal fluid findings suggest the diagnosis. Although nerve biopsy may be strongly supporting, we believe that it has to be performed only if doubts arise from the clinical, electrophysiological or spinal fluid observations. It is worth noting that its early detection may benefit the patient through the administration of the right therapy precluding the eventual sequelae of the disease.
Alrawashdeh, Omar; Alsbou, Mohammad; Alzoubi, Hamed; Al-shagahin, Hani
2017-01-01
Alkaptonuria is a rare metabolic disease characterised by accumulative deposition of homogentisic acid in the connective tissue of the body. This results in early degeneration of tendons, cartilages, heart valves, and other tissues. The main objective of the study is to examine the possibility of the nervous system involvement in patients with alkaptonuria The sample consists of two groups; 22 patients with AKU and 20 controls. A neurological assessment has been carried out including detailed medical history, neurological examination, and a nerve conduction study of the nerves of the dominant hand. The prevalence of any abnormality was compared between the two groups using chi square test. The mean values of the nerve conduction study were compared between the two groups using student t-test. There was a higher prevalence of low back pain, hearing problems and tinnitus, numbness and neuropathic pain in alkaptonuria patients. There was no significant difference between the two groups in other conditions such as seizures, headache, and syncope. The values of the nerve conduction study did not show significant difference between the two groups. Neurologically related symptoms in alkaptonuria mostly represent complications of the connective tissue degeneration rather than direct involvement of the nervous system. This has been supported further by the normal findings of the neurophysiology study in patients with alkaptonuria. PMID:28217270
ERIC Educational Resources Information Center
Wickett, John C.; Vernon, Philip A.
1994-01-01
In a study involving 38 adult females, nerve conduction velocity (NCV) did not correlate with intelligence or reaction time. A reanalysis of the Vernon and Mori data showed a possible sex difference in relation to NCV and intelligence, with the correlation between these variables much smaller in females than males. (SLD)
Takahashi, Mitsuo; Mitsui, Yoshiyuki; Yorifuji, Shiro; Nakamura, Yuusaku; Tsukamoto, Yoshihumi; Nishimoto, Kazuhiro
2007-09-01
We followed eight hereditary motor and sensory neuropathy patients with proximal dominance (HMSN-P) in Shiga prefecture from 1984 to 2007. There were 4 men and 4 women from two families showing autosomal and dominant prepotency. These families were related by marriage. The average onset of disease was at 53.4 +/- 8.9 (40-68) years-old. Initial symptoms were difficulty of standing up, difficulty elevating their arms, limping, or numbness. The main feature was neurogenic muscular atrophy with proximal dominance. All deep tendon reflexes were decreased or nonexistent. Paresthesia in the hands and feet and/or decreased vibratory sense in the legs were found in six patients. High CK blood levels were recognized in three patients. EMG in four patients revealed neurogenic pattern. Nerve conduction study was conducted in two patients. MCV of the median nerve and of the tibial posterior nerve, also SCV of the median nerve and of the sural nerve were within normal range in all nerves. Amplitudes of sensory action potential or of M wave were decreased or nonexistent in five of eight nerves, and distal latency of M waves was delayed in three of four nerves. These data suggests dysfunction of distal parts of the peripheral nerve fibers and axonal degeneration of the nerve trunk. Seven patients have died, and their average death age was 69.1 +/- 8.2 (52-77) years-old. Their average affected period was 16.6 (4-30) years. Their clinical history resembles Okinawa-type HMSN-P, but without the painful muscle cramps which are distinctive Okinawa-type signs.
Boric acid reduces axonal and myelin damage in experimental sciatic nerve injury
Kızılay, Zahir; Erken, Haydar Ali; Çetin, Nesibe Kahraman; Aktaş, Serdar; Abas, Burçin İrem; Yılmaz, Ali
2016-01-01
The aim of this study was to investigate the effects of boric acid in experimental acute sciatic nerve injury. Twenty-eight adult male rats were randomly divided into four equal groups (n = 7): control (C), boric acid (BA), sciatic nerve injury (I), and sciatic nerve injury + boric acid treatment (BAI). Sciatic nerve injury was generated using a Yasargil aneurysm clip in the groups I and BAI. Boric acid was given four times at 100 mg/kg to rats in the groups BA and BAI after injury (by gavage at 0, 24, 48 and 72 hours) but no injury was made in the group BA. In vivo electrophysiological tests were performed at the end of the day 4 and sciatic nerve tissue samples were taken for histopathological examination. The amplitude of compound action potential, the nerve conduction velocity and the number of axons were significantly lower and the myelin structure was found to be broken in group I compared with those in groups C and BA. However, the amplitude of the compound action potential, the nerve conduction velocity and the number of axons were significantly greater in group BAI than in group I. Moreover, myelin injury was significantly milder and the intensity of nuclear factor kappa B immunostaining was significantly weaker in group BAI than in group I. The results of this study show that administration of boric acid at 100 mg/kg after sciatic nerve injury in rats markedly reduces myelin and axonal injury and improves the electrophysiological function of injured sciatic nerve possibly through alleviating oxidative stress reactions. PMID:27904499
Boric acid reduces axonal and myelin damage in experimental sciatic nerve injury.
Kızılay, Zahir; Erken, Haydar Ali; Çetin, Nesibe Kahraman; Aktaş, Serdar; Abas, Burçin İrem; Yılmaz, Ali
2016-10-01
The aim of this study was to investigate the effects of boric acid in experimental acute sciatic nerve injury. Twenty-eight adult male rats were randomly divided into four equal groups ( n = 7): control (C), boric acid (BA), sciatic nerve injury (I), and sciatic nerve injury + boric acid treatment (BAI). Sciatic nerve injury was generated using a Yasargil aneurysm clip in the groups I and BAI. Boric acid was given four times at 100 mg/kg to rats in the groups BA and BAI after injury (by gavage at 0, 24, 48 and 72 hours) but no injury was made in the group BA. In vivo electrophysiological tests were performed at the end of the day 4 and sciatic nerve tissue samples were taken for histopathological examination. The amplitude of compound action potential, the nerve conduction velocity and the number of axons were significantly lower and the myelin structure was found to be broken in group I compared with those in groups C and BA. However, the amplitude of the compound action potential, the nerve conduction velocity and the number of axons were significantly greater in group BAI than in group I. Moreover, myelin injury was significantly milder and the intensity of nuclear factor kappa B immunostaining was significantly weaker in group BAI than in group I. The results of this study show that administration of boric acid at 100 mg/kg after sciatic nerve injury in rats markedly reduces myelin and axonal injury and improves the electrophysiological function of injured sciatic nerve possibly through alleviating oxidative stress reactions.
Nerve Conduction Study on Sural Nerve among Nepalese Tailors Using Mechanical Sewing Machine.
Yadav, Prakash Kumar; Yadav, Ram Lochan; Sharma, Deepak; Shah, Dev Kumar; Thakur, Dilip; Limbu, Nirmala; Islam, Md Nazrul
2017-03-01
The use of new technologies and innovations are out of access for people living in a developing country like Nepal. The mechanical sewing machine is still in existence at a large scale and dominant all over the country. Tailoring is one of the major occupations adopted by skilled people with lower socioeconomic status and education level. Sural nerves of both right and left legs are exposed to strenuous and chronic stress exerted by chronic paddling of mechanical sewing machine with legs. To evaluate the influence of chronic and strenuous paddling on right and left sural nerves. The study recruited 30 healthy male tailors with median age {34(31-37.25)} years (study group), and, 30 healthy male volunteers with age {34(32-36.25)} years (control group). Anthropometric measurements (age, height, weight, BMI and length of both right and left legs) as well as cardio respiratory measurements [Systolic Blood Pressure (SBP), Dystolic Blood Pressure (DBP), Pules Rate (PR) and Respiratory Rate (RR)] were recorded for each subject. Standard nerve conduction techniques using constant measured distances were applied to evaluate sural nerve (sensory) in both legs of each individual. The differences in variables between the study and control groups were tested using Student's t-test for parametric variables and Mann-Whitney U test for nonparametric variables. A p-value of ≤ 0.05 was considered significant. Age, height, weight, body mass index and leg length were not significantly different between tailors and control groups. Cardio respiratory measurements (SBP, DBP, PR and RR) were also not significantly altered between both the groups. The sensory nerve conduction velocities (m/s) of the right {44.23(42.72-47.83) vs 50(46- 54)} and left sural nerves {45.97±5.86 vs 50.67±6.59} m/s were found significantly reduced in tailors in comparison to control group. Similarly amplitudes (μv) of right sural (20.75±5.42 vs 24.10±5.45) and left sural nerves {18.2(12.43-21.8) vs 32.0(26.5-35.25)} were significantly less in tailors in comparison to control group whereas, latencies (ms) of right sural {2.6(2.2-2.7) vs 2.0(2.0-2.250} and left sural nerve {2.4(2.07-2.72) vs 2.0(2.0-2.0)} were found significantly high in tailors as compared with control group. Operating mechanical sewing machine by paddling chronically and arduously could have attributed to abnormal nerve conduction study parameters due to vibration effect of the machine on right and left sural nerves. The results of present study follow the trend towards presymptomatic or asymptomatic neuropathy similar to subclinical neuropathy.
Nerve Conduction Study on Sural Nerve among Nepalese Tailors Using Mechanical Sewing Machine
Yadav, Ram Lochan; Sharma, Deepak; Shah, Dev Kumar; Thakur, Dilip; Limbu, Nirmala; Islam, Md. Nazrul
2017-01-01
Introduction The use of new technologies and innovations are out of access for people living in a developing country like Nepal. The mechanical sewing machine is still in existence at a large scale and dominant all over the country. Tailoring is one of the major occupations adopted by skilled people with lower socioeconomic status and education level. Sural nerves of both right and left legs are exposed to strenuous and chronic stress exerted by chronic paddling of mechanical sewing machine with legs. Aim To evaluate the influence of chronic and strenuous paddling on right and left sural nerves. Materials and Methods The study recruited 30 healthy male tailors with median age {34(31-37.25)} years (study group), and, 30 healthy male volunteers with age {34(32-36.25)} years (control group). Anthropometric measurements (age, height, weight, BMI and length of both right and left legs) as well as cardio respiratory measurements [Systolic Blood Pressure (SBP), Dystolic Blood Pressure (DBP), Pules Rate (PR) and Respiratory Rate (RR)] were recorded for each subject. Standard nerve conduction techniques using constant measured distances were applied to evaluate sural nerve (sensory) in both legs of each individual. The differences in variables between the study and control groups were tested using Student’s t-test for parametric variables and Mann-Whitney U test for nonparametric variables. A p-value of ≤ 0.05 was considered significant. Results Age, height, weight, body mass index and leg length were not significantly different between tailors and control groups. Cardio respiratory measurements (SBP, DBP, PR and RR) were also not significantly altered between both the groups. The sensory nerve conduction velocities (m/s) of the right {44.23(42.72-47.83) vs 50(46- 54)} and left sural nerves {45.97±5.86 vs 50.67±6.59} m/s were found significantly reduced in tailors in comparison to control group. Similarly amplitudes (μv) of right sural (20.75±5.42 vs 24.10±5.45) and left sural nerves {18.2(12.43-21.8) vs 32.0(26.5-35.25)} were significantly less in tailors in comparison to control group whereas, latencies (ms) of right sural {2.6(2.2-2.7) vs 2.0(2.0-2.250} and left sural nerve {2.4(2.07-2.72) vs 2.0(2.0-2.0)} were found significantly high in tailors as compared with control group. Conclusion Operating mechanical sewing machine by paddling chronically and arduously could have attributed to abnormal nerve conduction study parameters due to vibration effect of the machine on right and left sural nerves. The results of present study follow the trend towards presymptomatic or asymptomatic neuropathy similar to subclinical neuropathy. PMID:28511376
Resistance of the peripheral nervous system to the effects of chronic canine hypothyroidism.
Rossmeisl, J H
2010-01-01
Hypothyroidism has been implicated in the development of multiple peripheral mono- and polyneuropathies in dogs. The objectives of this study were to evaluate the clinical and electrophysiologic effects of experimentally induced hypothyroidism on the peripheral nervous system of dogs. Chronic hypothyroidism will induce peripheral nerve sensorimotor dysfunction. Eighteen purpose-bred, female dogs. Prospective, longitudinal study: Hypothyroidism was induced by radioactive iodine administration in 9 dogs, and the remaining 9 served as untreated controls. Neurological examinations were performed monthly. Electrophysiologic testing consisting of electromyography (EMG); motor nerve conduction studies of the sciatic-tibial, radial, ulnar, and recurrent laryngeal nerves; sciatic-tibial and ulnar F-wave studies; sensory nerve conduction studies of the tibial, ulnar, and radial nerves; and evaluation of blink reflex and facial responses were performed before and 6, 12, and 18 months after induction of hypothyroidism and compared with controls. Clinical evidence of peripheral nervous dysfunction did not occur in any dog. At 6 month and subsequent evaluations, all hypothyroid dogs had EMG and histologic evidence of hypothyroid myopathy. Hypothyroid dogs had significant (P
Astrocytes in the optic nerve head express putative mechanosensitive channels
Choi, Hee Joo; Sun, Daniel
2015-01-01
Purpose To establish whether optic nerve head astrocytes express candidate molecules to sense tissue stretch. Methods We used conventional PCR, quantitative PCR, and single-cell reverse transcription PCR (RT–PCR) to assess the expression of various members of the transient receptor potential (TRP) channel family and of the recently characterized mechanosensitive channels Piezo1 and 2 in optic nerve head tissue and in single, isolated astrocytes. Results Most TRP subfamilies (TRPC, TRPM, TRPV, TRPA, and TRPP) and Piezo1 and 2 were expressed in the optic nerve head of the mouse. Quantitative real-time PCR analysis showed that TRPC1, TRPM7, TRPV2, TRPP2, and Piezo1 are the dominant isoforms in each subfamily. Single-cell RT–PCR revealed that many TRP isoforms, TRPC1–2, TRPC6, TRPV2, TRPV4, TRPM2, TRPM4, TRPM6–7, TRPP1–2, and Piezo1–2, are expressed in astrocytes of the optic nerve head, and that most astrocytes express TRPC1 and TRPP1–2. Comparisons of the TRPP and Piezo expression levels between different tissue regions showed that Piezo2 expression was higher in the optic nerve head and the optic nerve proper than in the brain and the corpus callosum. TRPP2 also showed higher expression in the optic nerve head. Conclusions Astrocytes in the optic nerve head express multiple putative mechanosensitive channels, in particular the recently identified channels Piezo1 and 2. The expression of putative mechanosensitive channels in these cells may contribute to their responsiveness to traumatic or glaucomatous injury. PMID:26236150
Sköld, Mattias K; Svensson, Mikael; Tsao, Jack; Hultgren, Thomas; Landegren, Thomas; Carlstedt, Thomas; Cullheim, Staffan
2011-01-01
The Karolinska Institutet 200-year anniversary symposium on injuries to the spinal cord and peripheral nervous system gathered expertise in the spinal cord, spinal nerve, and peripheral nerve injury field spanning from molecular prerequisites for nerve regeneration to clinical methods in nerve repair and rehabilitation. The topics presented at the meeting covered findings on adult neural stem cells that when transplanted to the hypoglossal nucleus in the rat could integrate with its host and promote neuron survival. Studies on vascularization after intraspinal replantation of ventral nerve roots and microarray studies in ventral root replantation as a tool for mapping of biological patterns typical for neuronal regeneration were discussed. Different immune molecules in neurons and glia and their very specific roles in synapse plasticity after injury were presented. Novel strategies in repair of injured peripheral nerves with ethyl-cyanoacrylate adhesive showed functional recovery comparable to that of conventional epineural sutures. Various aspects on surgical techniques which are available to improve function of the limb, once the nerve regeneration after brachial plexus lesions and repair has reached its limit were presented. Moreover, neurogenic pain after amputation and its treatment with mirror therapy were shown to be followed by dramatic decrease in phantom limb pain. Finally clinical experiences on surgical techniques to repair avulsed spinal nerve root and the motoric as well as sensoric regain of function were presented.
Sköld, Mattias K.; Svensson, Mikael; Tsao, Jack; Hultgren, Thomas; Landegren, Thomas; Carlstedt, Thomas; Cullheim, Staffan
2011-01-01
The Karolinska Institutet 200-year anniversary symposium on injuries to the spinal cord and peripheral nervous system gathered expertise in the spinal cord, spinal nerve, and peripheral nerve injury field spanning from molecular prerequisites for nerve regeneration to clinical methods in nerve repair and rehabilitation. The topics presented at the meeting covered findings on adult neural stem cells that when transplanted to the hypoglossal nucleus in the rat could integrate with its host and promote neuron survival. Studies on vascularization after intraspinal replantation of ventral nerve roots and microarray studies in ventral root replantation as a tool for mapping of biological patterns typical for neuronal regeneration were discussed. Different immune molecules in neurons and glia and their very specific roles in synapse plasticity after injury were presented. Novel strategies in repair of injured peripheral nerves with ethyl-cyanoacrylate adhesive showed functional recovery comparable to that of conventional epineural sutures. Various aspects on surgical techniques which are available to improve function of the limb, once the nerve regeneration after brachial plexus lesions and repair has reached its limit were presented. Moreover, neurogenic pain after amputation and its treatment with mirror therapy were shown to be followed by dramatic decrease in phantom limb pain. Finally clinical experiences on surgical techniques to repair avulsed spinal nerve root and the motoric as well as sensoric regain of function were presented. PMID:21629875
Gordon, Tessa; Chan, K Ming; Sulaiman, Olawale A R; Udina, Esther; Amirjani, Nasim; Brushart, Thomas M
2009-10-01
Injured peripheral nerves regenerate at very slow rates. Therefore, proximal injury sites such as the brachial plexus still present major challenges, and the outcomes of conventional treatments remain poor. This is in part attributable to a progressive decline in the Schwann cells' ability to provide a supportive milieu for the growth cone to extend and to find the appropriate target. These challenges are compounded by the often considerable delay of regeneration across the site of nerve laceration. Recently, low-frequency electrical stimulation (as brief as an hour) has shown promise, as it significantly accelerated regeneration in animal models through speeding of axon growth across the injury site. To test whether this might be a useful clinical tool, we carried out a randomized controlled trial in patients who had experienced substantial axonal loss in the median nerve owing to severe compression in the carpal tunnel. To further elucidate the potential mechanisms, we applied rolipram, a cyclic adenosine monophosphate agonist, to rats after axotomy of the femoral nerve. We demonstrated that effects similar to those observed in animal studies could also be attained in humans. The mechanisms of action of electrical stimulation likely operate through up-regulation of neurotrophic factors and cyclic adenosine monophosphate. Indeed, the application of rolipram significantly accelerated nerve regeneration. With new mechanistic insights into the influencing factors of peripheral nerve regeneration, the novel treatments described above could form part of an armament of synergistic therapies that could make a meaningful difference to patients with peripheral nerve injuries.
Promising Technique for Facial Nerve Reconstruction in Extended Parotidectomy.
Villarreal, Ithzel Maria; Rodríguez-Valiente, Antonio; Castelló, Jose Ramon; Górriz, Carmen; Montero, Oscar Alvarez; García-Berrocal, Jose Ramon
2015-11-01
Malignant tumors of the parotid gland account scarcely for 5% of all head and neck tumors. Most of these neoplasms have a high tendency for recurrence, local infiltration, perineural extension, and metastasis. Although uncommon, these malignant tumors require complex surgical treatment sometimes involving a total parotidectomy including a complete facial nerve resection. Severe functional and aesthetic facial defects are the result of a complete sacrifice or injury to isolated branches becoming an uncomfortable distress for patients and a major challenge for reconstructive surgeons. A case of a 54-year-old, systemically healthy male patient with a 4 month complaint of pain and swelling on the right side of the face is presented. The patient reported a rapid increase in the size of the lesion over the past 2 months. Imaging tests and histopathological analysis reported an adenoid cystic carcinoma. A complete parotidectomy was carried out with an intraoperative notice of facial nerve infiltration requiring a second intervention for nerve and defect reconstruction. A free ALT flap with vascularized nerve grafts was the surgical choice. A 6 month follow-up showed partial facial movement recovery and the facial defect mended. It is of critical importance to restore function to patients with facial nerve injury. Vascularized nerve grafts, in many clinical and experimental studies, have shown to result in better nerve regeneration than conventional non-vascularized nerve grafts. Nevertheless, there are factors that may affect the degree, speed and regeneration rate regarding the free fasciocutaneous flap. In complex head and neck defects following a total parotidectomy, the extended free fasciocutaneous ALT (anterior-lateral thigh) flap with a vascularized nerve graft is ideally suited for the reconstruction of the injured site. Donor-site morbidity is low and additional surgical time is minimal compared with the time of a single ALT flap transfer.
The "all-or-none" law in skeletal muscle and nerve fibres.
Pareti, G
2007-01-01
In 1905 the Cambridge physiologist Keith Lucas extended the "all-or-none" principle (introduced by H. P. Bowditch for the cardiac tissue) to skeletal muscle and nerve fibres. Nevertheless, in a short time it was clear that nerve fibres obey this law, but also that frequency of discharge is another relevant factor in the nervous conduction.
Neurostimulation for Treatment of Migraine and Cluster Headache
Schwedt, Todd J.; Vargas, Bert
2015-01-01
Objective The objective of this narrative review was to summarize the current state of neurostimulation therapies for the treatment of migraine and/or cluster. Methods For this narrative review, publications were identified by searching PubMed using the search terms “migraine” or “cluster” combined with “vagal nerve stimulation”, “transcranial magnetic stimulation”, “supraorbital nerve stimulation”, “sphenopalatine ganglion stimulation”, “occipital nerve stimulation”, “deep brain stimulation”, “neurostimulation”, or “neuromodulation”. Publications were chosen based upon the quality of data that were provided and their relevance to the chosen topics of interest for this review. Reference lists of chosen articles and the authors own files were used to identify additional publications. Current clinical trials were identified by searching clinicaltrials.org. Results and Conclusions Neurostimulation of the vagal nerve, supraorbital nerve, occipital nerve and sphenopalatine ganglion, transcranial magnetic stimulation, and deep brain stimulation have been investigated for the treatment of migraine and/or cluster. Whereas invasive methods of neurostimulation would be reserved for patients with very severe and treatment refractory migraine or cluster, non-invasive methods of stimulation might serve as useful adjuncts to more conventional therapies. Currently, transcutaneous supraorbital nerve stimulation is FDA approved and commercially available for migraine prevention and transcranial magnetic stimulation is FDA approved for the treatment of migraine with aura. The potential utility of each type of neurostimulation has yet to be completely defined. PMID:26177612
Muchlinski, Magdalena N; Deane, Andrew S
2016-07-01
The mandibular nerve is a sensory and motor nerve that innervates the muscles of mastication, the lower dentition, and the lower lip and surrounding structures. Although this nerve contains both efferent and afferent fibers, the mental nerve, a terminal branch of the mandibular nerve, is a strictly sensory nerve that exits the mental foramen and innervates the lower lip, the skin overlaying the mandible, and the oral mucosa around the mandible. Osteological foramina are often used as proxies for nerve cross section area and they often correlate well with some aspect of a primate's ecology (e.g., optic foramen and visual acuity). The primary objective of this study is to explore the correlation between the mental foramen and dietary preference among primates. The mental foramen of 40 primate species (n = 180) was measured from 3-D surface models of the mandible. Both conventional and phylogenetic tests indicate that although frugivores have larger mental foramina than folivores, the differences were not significant. These results show that while structures like the infraorbital foramen correlate well with diet and touch sensitivity, the mental foramen does not. Based on these findings, the mental foramen is not a suggested morphological character for interpreting of the fossil record. J. Morphol. 277:978-985, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Quantifying Demyelination in NK venom treated nerve using its electric circuit model
NASA Astrophysics Data System (ADS)
Das, H. K.; Das, D.; Doley, R.; Sahu, P. P.
2016-03-01
Reduction of myelin in peripheral nerve causes critical demyelinating diseases such as chronic inflammatory demyelinating polyneuropathy, Guillain-Barre syndrome, etc. Clinical monitoring of these diseases requires rapid and non-invasive quantification of demyelination. Here we have developed formulation of nerve conduction velocity (NCV) in terms of demyelination considering electric circuit model of a nerve having bundle of axons for its quantification from NCV measurements. This approach has been validated and demonstrated with toad nerve model treated with crude Naja kaouthia (NK) venom and also shows the effect of Phospholipase A2 and three finger neurotoxin from NK-venom on peripheral nerve. This opens future scope for non-invasive clinical measurement of demyelination.
Quantifying Demyelination in NK venom treated nerve using its electric circuit model
Das, H. K.; Das, D.; Doley, R.; Sahu, P. P.
2016-01-01
Reduction of myelin in peripheral nerve causes critical demyelinating diseases such as chronic inflammatory demyelinating polyneuropathy, Guillain-Barre syndrome, etc. Clinical monitoring of these diseases requires rapid and non-invasive quantification of demyelination. Here we have developed formulation of nerve conduction velocity (NCV) in terms of demyelination considering electric circuit model of a nerve having bundle of axons for its quantification from NCV measurements. This approach has been validated and demonstrated with toad nerve model treated with crude Naja kaouthia (NK) venom and also shows the effect of Phospholipase A2 and three finger neurotoxin from NK-venom on peripheral nerve. This opens future scope for non-invasive clinical measurement of demyelination. PMID:26932543
Quantifying Demyelination in NK venom treated nerve using its electric circuit model.
Das, H K; Das, D; Doley, R; Sahu, P P
2016-03-02
Reduction of myelin in peripheral nerve causes critical demyelinating diseases such as chronic inflammatory demyelinating polyneuropathy, Guillain-Barre syndrome, etc. Clinical monitoring of these diseases requires rapid and non-invasive quantification of demyelination. Here we have developed formulation of nerve conduction velocity (NCV) in terms of demyelination considering electric circuit model of a nerve having bundle of axons for its quantification from NCV measurements. This approach has been validated and demonstrated with toad nerve model treated with crude Naja kaouthia (NK) venom and also shows the effect of Phospholipase A2 and three finger neurotoxin from NK-venom on peripheral nerve. This opens future scope for non-invasive clinical measurement of demyelination.
Weigert, M; Mellerowicz, H; Werhahn, C
1975-10-01
Isolated division of the tibial nerve in the thigh preserving the peroneal and sural nerves does not cause loss of normal position of the animal, in particular of sitting. Nor does it lead to pressure sores. The animals are fitter then after division of the sciatic nerve. Microsurgical suture of the isolated tibial nerve in the thigh of the rabbit with 1 or 2 simple sutures with 10 x 0 thread show that an average recovery can be achieved in over 80 per cent. As few sutures as possible should be used. Otherwise there with be scarring and no return of function.
Platon, B; Andréll, P; Raner, C; Rudolph, M; Dvoretsky, A; Mannheimer, C
2010-01-01
The aim of the study was to compare the pain-relieving effect and the time spent in the recovery ward after treatment with high-frequency, high-intensity transcutaneous electrical nerve stimulation (TENS) or intravenous (IV) conventional pharmacological treatment after surgical abortion. Two-hundred women who underwent surgical abortion and postoperatively reported a visual analogue scale (VAS) pain score3 were included. The patients were randomised to TENS or conventional pharmacological treatment for their postoperative pain. The TENS treatment was given with a stimulus intensity between 20 and 60 mA during 1 min and repeated once if insufficient pain relief (VAS3). In the conventional pharmacological treatment group, a maximum dose of 100 microg fentanyl was given IV. There was no difference between the groups with regard to pain relief according to the VAS pain score (TENS=VAS 1.3 vs. IV opioids=VAS 1.6; p=0.09) upon discharge from the recovery ward. However, the patients in the TENS group spent shorter time (44 min) in the recovery ward than the conventional pharmacological treatment group (62 min; p<0.0001). The number of patients who needed additional analgesics in the recovery ward was comparable in both groups, as was the reported VAS pain score upon leaving the hospital (TENS=2.0 vs. conventional pharmacological treatment=1.8, NS). These results suggest that the pain-relieving effect of TENS seems to be comparable to conventional pharmacological treatment with IV opioids. Hence, TENS may be a suitable alternative to conventional pain management with IV opioids after surgical abortion. Copyright 2009 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
Miconazole enhances nerve regeneration and functional recovery after sciatic nerve crush injury.
Lin, Tao; Qiu, Shuai; Yan, Liwei; Zhu, Shuang; Zheng, Canbin; Zhu, Qingtang; Liu, Xiaolin
2018-05-01
Improving axonal outgrowth and remyelination is crucial for peripheral nerve regeneration. Miconazole appears to enhance remyelination in the central nervous system. In this study we assess the effect of miconazole on axonal regeneration using a sciatic nerve crush injury model in rats. Fifty Sprague-Dawley rats were divided into control and miconazole groups. Nerve regeneration and myelination were determined using histological and electrophysiological assessment. Evaluation of sensory and motor recovery was performed using the pinprick assay and sciatic functional index. The Cell Counting Kit-8 assay and Western blotting were used to assess the proliferation and neurotrophic expression of RSC 96 Schwann cells. Miconazole promoted axonal regrowth, increased myelinated nerve fibers, improved sensory recovery and walking behavior, enhanced stimulated amplitude and nerve conduction velocity, and elevated proliferation and neurotrophic expression of RSC 96 Schwann cells. Miconazole was beneficial for nerve regeneration and functional recovery after peripheral nerve injury. Muscle Nerve 57: 821-828, 2018. © 2017 Wiley Periodicals, Inc.
Pachuski, Justin; Vaida, Sonia; Donahue, Kathleen; Roberts, John; Kunselman, Allen; Oberman, Benjamin; Patel, Hetal; Goldenberg, David
2016-03-01
Intraoperative neuromonitoring of the recurrent laryngeal nerve (RLN) is often used as an adjunct for RLN identification and preservation during thyroidectomies. Laryngotracheal anesthesia (LTA) with topical lidocaine reduces coughing upon emergence from anesthesia and in the immediate postoperative period; however, its use is prohibited with concerns that it could decrease the sensitivity of the intraoperative neuromonitoring. We hypothesize that there is no difference in measurements of nerve conduction made before and after LTA administration. An observational study in which all patients were subjected to LTA administration was conducted. Recurrent laryngeal nerve threshold currents were measured before and after the intervention. Tertiary medical center operating room. Eighteen patients (total of 25 nerves at risk) with American Society of Anesthesiologists classes 1 to 3 undergoing thyroid surgery. After the thyroid was removed and threshold currents at the RLN were obtained, LTA with endotracheal lidocaine was applied on the left and right side of the in situ endotracheal tube (2 cc of 4% lidocaine per side). Threshold currents were reassessed at 5 and 10 minutes after LTA administration. Threshold currents (minimum stimulus current applied to the RLN required to generate a discernible electromyographic response at the vocal cords) were recorded along the RLN for a baseline at 5 and 10 mm from the insertion point of the RLN into the larynx. Threshold currents were reassessed at the same 2 positions on the RLN at 5 and 10 minutes after LTA administration. Differences in mean values, between threshold currents recorded at the 3 different times, at 2 positions on the RLN, were used to compare effects of LTA on nerve conduction. There were no statistically significant differences when comparing threshold currents before and after LTA administration. Laryngotracheal anesthesia had no significant effect on RLN nerve conduction in the period assessed. Copyright © 2016 Elsevier Inc. All rights reserved.
[F-waves in brachial plexus palsy correlated to the prognosis of intrinsic paralysis].
Nobuta, S
1995-04-01
F-waves were examined in 80 nerves of 40 brachial plexus palsies in 37 cases. The electrical responses were evoked by 30 consecutive supramaximal electric stimuli to the median and ulnar nerves at the wrist and elbow, and recorded from the abductor pollicis brevis and abductor digiti minimi muscles. Three parameters in the F-waves were analyzed--conduction velocity, the difference between the maximal and minimal latencies, and the amplitude. In all cases, examinations were done repeatedly to detect changes in these parameters, and the results were compared with the clinical course of the intrinsic muscle function. Twenty-seven cases were investigated before and after explorative surgery. The findings were divided into four groups. The 1st group consisted of 12 nerves in which F-waves were not recorded. The intrinsic muscle power in this group was zero, and did not show any restoration. The 2nd group consisted of 10 nerves in which the conduction velocity was delayed. The muscle power in this group was fair, poor or trace, and there was no change in conduction velocity and muscle function. The 3rd group consisted of 18 nerves in which parameters other than the conduction velocity were abnormal, and the intrinsic muscle power in this group was fair, good or normal. In 7 of these nerves, the large latency difference decreased to normal at the 2nd, 3rd or 4th test with functional recovery in the intrinsic muscle. The high amplitude also changed to normal at the 2nd test with functional recovery. The 4th group consisted of 40 nerves in which all the parameters were normal and had full intrinsic muscle power. In conclusion, an examination of the F-waves was valuable to indicate the prognosis of the intrinsic muscle in the hand in brachial plexus palsy.
Ishibashi, Fukashi; Kojima, Rie; Taniguchi, Miki; Kosaka, Aiko; Uetake, Harumi; Tavakoli, Mitra
2016-01-01
This study aims to establish the corneal nerve fiber (CNF) morphological alterations in a large cohort of type 2 diabetic patients and to investigate the association between the bead size, a novel parameter representing composite of accumulated mitochondria, glycogen particles, and vesicles in CNF, and the neurophysiological dysfunctions of the peripheral nerves. 162 type 2 diabetic patients and 45 healthy control subjects were studied in detail with a battery of clinical and neurological examinations and corneal confocal microscopy. Compared with controls, patients had abnormal CNF parameters. In particular the patients had reduced density and length of CNF and beading frequency and increased bead size. Alterations in CNF parameters were significant even in patients without neuropathy. The HbA1c levels were tightly associated with the bead size, which was inversely related to the motor and sensory nerve conduction velocity (NCV) and to the distal latency period of the median nerve positively. The CNF density and length positively correlated with the NCV and amplitude. The hyperglycemia-induced expansion of beads in CNF might be a predictor of slow NCV in peripheral nerves in type 2 diabetic patients.
The role of neural precursor cells and self assembling peptides in nerve regeneration
2013-01-01
Objective Cranial nerve injury involves loss of central neural cells in the brain stem and surrounding support matrix, leading to severe functional impairment. Therapeutically targeting cellular replacement and enhancing structural support may promote neural regeneration. We examined the combinatorial effect of neural precursor cells (NPC) and self assembling peptide (SAP) administration on nerve regeneration. Methods Nerve injury was induced by clip compression of the rodent spinal cord. SAPs were injected immediately into the injured cord and NPCs at 2 weeks post-injury. Behavioral analysis was done weekly and rats were sacrificed at 11 weeks post injury. LFB-H&E staining was done on cord tissue to assess cavitation volume. Motor evoked potentials (MEP) were measured at week 11 to assess nerve conduction and Kaplan meier curves were created to compare survival estimates. Results NPCs and SAPs were distributed both caudal and rostral to the injury site. Behavioral analysis showed that SAP + NPC transplantation significantly improved locomotor score p <0.03) and enhanced survival (log rank test, p = 0.008) compared to control. SAP + NPC treatment also improved nerve conduction velocity (p = 0.008) but did not affect cavitation volume (p = 0.73). Conclusion Combinatorial NPC and SAP injection into injured nerve tissue may enhance neural repair and regeneration. PMID:24351041
The role of neural precursor cells and self assembling peptides in nerve regeneration.
Zhao, Xiao; Yao, Gordon S; Liu, Yang; Wang, Jian; Satkunendrarajah, Kajana; Fehlings, Michael
2013-12-19
Cranial nerve injury involves loss of central neural cells in the brain stem and surrounding support matrix, leading to severe functional impairment. Therapeutically targeting cellular replacement and enhancing structural support may promote neural regeneration. We examined the combinatorial effect of neural precursor cells (NPC) and self assembling peptide (SAP) administration on nerve regeneration. Nerve injury was induced by clip compression of the rodent spinal cord. SAPs were injected immediately into the injured cord and NPCs at 2 weeks post-injury. Behavioral analysis was done weekly and rats were sacrificed at 11 weeks post injury. LFB-H&E staining was done on cord tissue to assess cavitation volume. Motor evoked potentials (MEP) were measured at week 11 to assess nerve conduction and Kaplan Meier curves were created to compare survival estimates. NPCs and SAPs were distributed both caudal and rostral to the injury site. Behavioral analysis showed that SAP + NPC transplantation significantly improved locomotor score p <0.03) and enhanced survival (log rank test, p = 0.008) compared to control. SAP + NPC treatment also improved nerve conduction velocity (p = 0.008) but did not affect cavitation volume (p = 0.73). Combinatorial NPC and SAP injection into injured nerve tissue may enhance neural repair and regeneration.
A-waves increase the risk of developing neuropathy.
Srotova, Iva; Vlckova, Eva; Dusek, Ladislav; Bednarik, Josef
2017-08-01
A-waves, which are observed following the M-wave during motor nerve conduction studies (NCS), are late responses that are frequently found in many types of neurogenic disorders. However, A-waves are also common in healthy individuals, where their significance remains unclear. The aim of this study was to examine whether the occurrence of A-waves does in fact represent an increased risk for the future development of changes upon NCS or needle electromyography (EMG) in the corresponding nerve. Nerve conduction studies/needle electromyography findings at control examination were evaluated in relation to the occurrence of initial A-waves in 327 individuals who had undergone repeated NCS/EMG examination and exhibited normal initial findings, with or without the occurrence of A-waves as the only acceptable abnormality. The odds ratio, which reflects the predictive power of the occurrence of A-waves at the initial testing for the development of an abnormality (neuropathy or radiculopathy) at the follow-up examination, ranged from 2.7 ( p = .041) in the tibial nerve and 3.9 ( p = .034) in peroneal one, to 30.0 ( p = .002) in the ulnar nerve. A-waves constitute an initial abnormality in all nerves, and they may be predictive for the future development of broader NCS/EMG abnormalities in the corresponding nerve.
Total thyroidectomy with ultrasonic dissector for cancer: multicentric experience
2012-01-01
Background We conducted an observational multicentric clinical study on a cohort of patients undergoing thyroidectomy for thyroid carcinoma. The aim of this study was to evaluate the benefits of the use of ultrasonic dissector (UAS) vs. the use of a conventional technique (vessel clamp and tie) in patients undergoing thyroid surgery for cancer. Methods From June 2009 to May 2010 we evaluated 321 consecutive patients electively admitted to undergo total thyroidectomy for thyroid carcinoma. The first 201 patients (89 males, 112 females) presenting to our Department underwent thyroidectomy with the use of UAS while the following 120 patients (54 males, 66 females) underwent thyroidectomy performed with a conventional technique (CT): vessel clamp and tie. Results The operative time (mean: 75 min in UAS vs. 113 min in CT, range: 54 to 120 min in UAS vs. 68 to 173 min in CT) was much shorter in the group of thyroidectomies performed with UAS. The incidence of transient laryngeal nerve palsy (UAS 3/201 patients (1.49%); CT 1/120 patients (0.83%)) was higher in the group of UAS; the incidence of permanent laryngeal nerve palsy was similar in the two groups (UAS 2/201 patients (0.99%) vs. CT 2/120 patients (1.66%)). The incidence of transient hypocalcaemia (UAS 17/201 patients (8.4%) vs. CT 9/120 patients (7.5%)) was higher in the UAS group; no relevant differences were reported in the incidence of permanent hypocalcaemia in the two groups (UAS 5/201 patients (2.48%) vs. 2/120 patients (1.66%)). Also the average postoperative length of stay was similar in two groups (2 days). Conclusion The only significant advantage proved by this study is represented by the cost-effectiveness (reduction of the usage of operating room) for patients treated with UAS, secondary to the significant reduction of the operative time. The analysis failed to show any advantages in terms of postoperative transient complications in the group of patients treated with ultrasonic dissector: transient laryngeal nerve palsy (1.49% in UAS vs. 0.83% in CT) and transient hypocalcaemia (8.4% in UAS vs. 7.5%in CT). No significant differences in the incidence of permanent laryngeal nerve palsy (0.8% in UAS vs. 1.04% in CT) and permanent hypocalcaemia (2.6% in UAS vs. 2.04% in CT) were demonstrated. The level of surgeons’ expertise is a central factor, which can influence the complications rate; the use of UAS can only help surgical action but cannot replace the experience of the operator. PMID:22540914
Iria, Inês; Alves, Sara; Farinho, Ana; Pen, Cláudia; Lourenço-Silva, Nuno; Mascarenhas-Lemos, Luís; Silva-Ferreira, José; Ferraz-Oliveira, Mário; Vassilenko, Valentina; Videira, Paula Alexandra; Goyri-O’Neill, João; Pais, Diogo
2018-01-01
The aim of this study was to evaluate in the Wistar rat the efficacy of various autologous nerve conduits with various forms of blood supply in reconstructing a 10-mm-long gap in the median nerve (MN) under conditions of local ischemia. A 10-mm-long median nerve defect was created in the right arm. A loose silicone tube was placed around the nerve gap zone, in order to simulate a local ischemic environment. Rats were divided in the following experimental groups (each with 20 rats): the nerve Graft (NG) group, in which the excised MN segment was reattached; the conventional nerve flap (CNF) and the arterialized neurovenous flap (ANVF) groups in which the gap was bridged with homonymous median nerve flaps; the prefabricated nerve flap (PNF) group in which the gap was reconstructed with a fabricated flap created by leaving an arteriovenous fistula in contact with the sciatic nerve for 5 weeks; and the two control groups, Sham and Excision groups. In the latter group, the proximal stump of the MN nerve was ligated and no repair was performed. The rats were followed for 100 days. During this time, they did physiotherapy. Functional, electroneuromyographic and histological studies were performed. The CNF and ANVF groups presented better results than the NG group in the following assessments: grasping test, nociception, motor stimulation threshold, muscle weight, and histomorphometric evaluation. Radial deviation of the operated forepaw was more common in rats that presented worse results in the other outcome variables. Overall, CNFs and ANVFs produced a faster and more complete recovery than NGs in the reconstruction of a 10-mm-long median nerve gap in an ischemic environment in the Wistar rat. Although, results obtained with CNFs were in most cases were better than ANVFs, these differences were not statistically significant for most of the outcome variables. PMID:29659600
Intraseptal anesthesia: a review of a relevant injection technique.
Woodmansey, Karl
2005-01-01
Although overshadowed by intraosseous anesthesia and the periodontal ligament injection, intraseptal anesthesia remains a useful local anesthesia technique for general dentists. Intraseptal anesthesia can be employed with safety and efficacy as an alternative to conventional local infiltration or regional nerve block injections. It also can serve as an adjunctive technique when conventional techniques fail to achieve adequate local anesthesia. This article reviews the intraseptal anesthesia technique, including its indications and limitations.
da Silva Oliveira, Victória R; Cury, Diego P; Yamashita, Laura B; Esteca, Marcos V; Watanabe, Ii-Sei; Bergmann, Yoko Fee; Toniolo, Elaine F; Dale, Camila S
2018-05-11
Diabetic peripheral neuropathy (DPN) is a nervous disorder caused by diabetes mellitus, affecting about 50% of patients in clinical medicine. Chronic pain is one of the major and most unpleasant symptoms developed by those patients, and conventional available treatments for the neuropathy, including the associated pain, are still unsatisfactory and benefit only a small number of patients. Photobiomodulation (PBM) has been gaining clinical acceptance once it is able to promote early nerve regeneration resulting in significant improvement in peripheral nerves disabilities. In this work, the effects of PBM (660 nm, 30 mW, 1.6 J/cm 2 , 0.28 cm 2 , 15 s in a continuous frequency) on treating DPN-induced pain and nerve damage were evaluated in an experimental model of diabetic-neuropathy induced by streptozotocin in mice. PBM-induced antinociception in neuropathic-pain mice was dependent on central opioids release. After 21 consecutive applications, PBM increased nerve growth factor levels and induced structural recovery increasing mitochondrial content and regulating Parkin in the sciatic nerve of DPN-mice. Taking together, these data provide new insights into the mechanisms involved in the effects of PBM-therapy emphasizing its therapeutic potential in the treatment of DPN. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Yadav, Prakash Kumar; Yadav, Ram Lochan; Sharma, Deepak; Shah, Dev Kumar; Sapkota, Niraj Khatri; Thakur, Dilip; Limbu, Nirmala; Islam, Md Nazrul
2017-01-01
Most of the people associated with tailoring occupation in Nepal are still using mechanical sewing machine as an alternative of new technology for tailoring. Common peroneal nerves of both right and left legs are exposed to strenuous and chronic stress exerted by vibration and paddling of mechanical sewing machine. The study included 30 healthy male tailors and 30 healthy male individuals. Anthropometric variables as well as cardio respiratory variables were determined for each subject. Standard Nerve Conduction Techniques using constant measured distances were applied to evaluate common peroneal nerve (motor) in both legs of each individual. Data were analyzed and compared between study and control groups using Man Whitney U test setting the significance level p ≤ 0.05. Anthropometric and cardio respiratory variables were not significantly altered between the study and control groups. The Compound muscle action potential (CMAP) latency of common peroneal nerves of both right [(11.29 ± 1.25 vs. 10.03 ± 1.37), P < 0.001] and left [(11.28 ± 1.38 vs. 10.05 ± 1.37), P < 0.01] legs was found to be significantly prolonged in study group as compared to control group. The Amp-CMAP of common peroneal nerves of both right [(4.57 ± 1.21 vs. 6.22 ± 1.72), P < 0.001] and left [(4.31 ± 1.55 vs. 6.25 ± 1.70), P < 0.001] legs was found significantly reduced in study group as compared to control group. Similarly, the motor nerve conduction velocity (MNCV) of common peroneal nerves of both right [(43.72 ± 3.25 vs. 47.49 ± 4.17), P < 0.001] and left [(42.51 ± 3.82 vs. 46.76 ± 4.51), P < 0.001] legs was also found to be significantly reduced in study group in comparison to control group. Operating mechanical sewing machine by paddling chronically and arduously could have attributed to abnormal nerve conduction study parameters due to vibration effect of the machine on right and left common peroneal nerves. The results of present study follow the trend towards presymptomatic or asymptomatic neuropathy similar to subclinical neuropathy.
Wang, Ting-Yun; Chen, Shih-Ching; Peng, Chih-Wei; Kang, Chun-Wei; Chen, Yu-Luen; Chen, Chun-Lung; Chou, Yi-Lin; Lai, Chien-Hung
2017-03-01
Purpose This study investigated the relationship between peripheral nerve conduction velocity (NCV) and balance performance in older adults with diabetes. Methods Twenty older adults with diabetes were recruited to evaluate the NCV of their lower limbs and balance performance. The balance assessments comprised the timed up and go (TUG) test, Berg balance scale (BBS), unipedal stance test (UST), multidirectional reach test (MDRT), maximum step length (MSL) test and quiet standing with eyes open and closed. The relationship between NCV and balance performance was evaluated by Pearson's correlation coefficients, and the balance performances of the diabetic patients with and without peripheral neuropathy were compared by using Mann-Whitney U tests. Results The NCV in the lower limbs exhibited a moderate to strong correlation with most of the balance tests including the TUG (r = -0.435 to -0.520, p < 0.05), BBS (r = 0.406-0.554, p < 0.05), UST (r = 0.409-0.647, p < 0.05) and MSL (r = 0.399-0.585, P < 0.05). In addition, patients with diabetic peripheral neuropathy had a poorer TUG (p < 0.05), BBS (p < 0.01), UST (p < 0.05) and MSL performance (p < 0.05) compared with those without peripheral neuropathy (p < 0.05). Conclusion Our findings revealed that a decline in peripheral nerve conduction in the lower limb is not only an indication of nerve dysfunction, but may also be related to the impairment of balance performance in patients with diabetes. Implications for Rehabilitation Nerve conduction velocity in the lower limbs of diabetic older adults showed moderate to strong correlations with most of the results of balance tests, which are commonly used in clinics. Decline in nerve conduction velocity of the lower limbs may be related to the impairment of balance control in patients with diabetes. Diabetic older adults with peripheral neuropathy exhibited greater postural instability than those without peripheral neuropathy.
NASA Astrophysics Data System (ADS)
Maharbiz, Michel M.
2017-05-01
The emerging field of bioelectronic medicine seeks methods for deciphering and modulating electrophysiological activity in the body to attain therapeutic effects at target organs. Current approaches to interfacing with peripheral nerves and muscles rely heavily on wires, creating problems for chronic use, while emerging wireless approaches lack the size scalability necessary to interrogate small-diameter nerves. Furthermore, conventional electrode-based technologies lack the capability to record from nerves with high spatial resolution or to record independently from many discrete sites within a nerve bundle. We recently demonstrated (Seo et al., arXiV, 2013; Seo et al., Neuron, 2016) "neural dust," a wireless and scalable ultrasonic backscatter system for powering and communicating with implanted bioelectronics. There, we showed that ultrasound is effective at delivering power to mm-scale devices in tissue; likewise, passive, battery-less communication using backscatter enabled high-fidelity transmission of electromyogram (EMG) and electroneurogram (ENG) signals from anesthetized rats. In this talk, I will review recent developments from my group and collaborators in this area.
Tang, Wei; Chen, Xiangfang; Liu, Haoqi; Lv, Qian; Zou, Junjie; Shi, Yongquan; Liu, Zhimin
2018-04-26
High glucose-induced oxidative stress and inflammatory responses play an important role in painful diabetic neuropathy by activating the TLR4/NFκB signal pathway. Schwann cells (SCs) are integral to peripheral nerve biology, contributing to saltatory conduction along axons, nerve and axon development, and axonal regeneration. SCs provide a microenvironment favoring vascular regeneration but their low survival ratio in hyperglycemic conditions suppress the function to promote nerve growth. Nuclear factor erythroid 2-related factor 2 (Nrf2) promotes remyelination after peripheral nerve injury. The aim of this study was to identify the role of Nrf2 in SC-mediated functional recovery after sciatic nerve injury. We compared plasma inflammatory factors in diabetic patients (DN) with/without diabetic peripheral neuropathy (DPN) and assessed whether Nrf2 expression in SCs could repair peripheral nerve injury in a rat model. Nrf2, TLR4/NFκB signal pathway and apoptosis relative protein expression were detected by western blot. Apoptosis and angiogenesis were determined by immunofluorescence and tubule formation assay, respectively. Regenerated nerves were determined by transmission electron microscope. Higher levels of inflammatory factors and VEGF expression were found in DPN patients. Cellular experiments indicate that Nrf2 expression inhibits hyperglycemia-induced apoptosis and promotes angiogenesis by regulating the TLR4/NFκB signal pathway. Animal experiments show that nerve conduction velocity, myelin sheath thickness, and sciatic vasa nervorum are restored with transplantation of SCs overexpressing Nrf2. Taken together, the high survival ratio of SCs in a DPN rat model indicates that overexpression of Nrf2 restores nerve injury. © 2018 The Author(s). Published by S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kinsella, T.J.; DeLuca, A.M.; Barnes, M.
1991-04-01
Radiation injury to peripheral nerve is a dose-limiting toxicity in the clinical application of intraoperative radiotherapy, particularly for pelvic and retroperitoneal tumors. Intraoperative radiotherapy-related peripheral neuropathy in humans receiving doses of 20-25 Gy is manifested as a mixed motor-sensory deficit beginning 6-9 months following treatment. In a previous experimental study of intraoperative radiotherapy-related neuropathy of the lumbro-sacral plexus, an approximate inverse linear relationship was reported between the intraoperative dose (20-75 Gy range) and the time to onset of hind limb paresis (1-12 mos following intraoperative radiotherapy). The principal histological lesion in irradiated nerve was loss of large nerve fibers andmore » perineural fibrosis without significant vascular injury. Similar histological changes in irradiated nerves were found in humans. To assess peripheral nerve injury to lower doses of intraoperative radiotherapy in this same large animal model, groups of four adult American Foxhounds received doses of 10, 15, or 20 Gy to the right lumbro-sacral plexus and sciatic nerve using 9 MeV electrons. The left lumbro-sacral plexus and sciatic nerve were excluded from the intraoperative field to allow each animal to serve as its own control. Following treatment, a complete neurological exam, electromyogram, and nerve conduction studies were performed monthly for 1 year. Monthly neurological exams were performed in years 2 and 3 whereas electromyogram and nerve conduction studies were performed every 3 months during this follow-up period. With follow-up of greater than or equal to 42 months, no dog receiving 10 or 15 Gy IORT shows any clinical or laboratory evidence of peripheral nerve injury. However, all four dogs receiving 20 Gy developed right hind limb paresis at 8, 9, 9, and 12 mos following intraoperative radiotherapy.« less
Early identification of 'acute-onset' chronic inflammatory demyelinating polyneuropathy.
Sung, Jia-Ying; Tani, Jowy; Park, Susanna B; Kiernan, Matthew C; Lin, Cindy Shin-Yi
2014-08-01
Distinguishing patients with acute-onset chronic inflammatory demyelinating polyneuropathy from acute inflammatory demyelinating polyneuropathy prior to relapse is often challenging at the onset of their clinical presentation. In the present study, nerve excitability tests were used in conjunction with the clinical phenotype and disease staging, to differentiate between patients with acute-onset chronic inflammatory demyelinating polyneuropathy and patients with acute inflammatory demyelinating polyneuropathy at an early stage, with the aim to better guide treatment. Clinical assessment, staging and nerve excitability tests were undertaken on patients initially fulfilling the diagnostic criteria of acute inflammatory demyelinating polyneuropathy soon after symptom onset and their initial presentation. Patients were subsequently followed up for minimum of 12 months to determine if their clinical presentations were more consistent with acute-onset chronic inflammatory demyelinating polyneuropathy. Clinical severity as evaluated by Medical Research Council sum score and Hughes functional grading scale were not significantly different between the two cohorts. There was no difference between the time of onset of initial symptoms and nerve excitability test assessment between the two cohorts nor were there significant differences in conventional nerve conduction study parameters. However, nerve excitability test profiles obtained from patients with acute inflammatory demyelinating polyneuropathy demonstrated abnormalities in the recovery cycle of excitability, including significantly reduced superexcitability (P < 0.001) and prolonged relative refractory period (P < 0.01), without changes in threshold electrotonus. In contrast, in patients with acute-onset chronic inflammatory demyelinating polyneuropathy, a different pattern occurred with the recovery cycle shifted downward (increased superexcitability, P < 0.05; decreased subexcitability, P < 0.05) and increased threshold change in threshold electrotonus in both hyperpolarizing and depolarizing directions [depolarizing threshold electrotonus (90-100 ms) P < 0.005, hyperpolarizing threshold electrotonus (10-20 ms), P < 0.01, hyperpolarizing threshold electrotonus (90-100 ms), P < 0.05], perhaps suggesting early hyperpolarization. In addition, using excitability parameters superexcitability, subexcitability and hyperpolarizing threshold electrotonus (10-20 ms), the patients with acute inflammatory demyelinating polyneuropathy and acute-onset chronic inflammatory demyelinating polyneuropathy could be clearly separated into two non-overlapping groups. Studies of nerve excitability may be able to differentiate acute from acute-onset chronic inflammatory demyelinating polyneuropathy at an early stage. Characteristic nerve excitability parameter changes occur in early acute-onset chronic inflammatory demyelinating polyneuropathy, to match the clinical phenotype. Importantly, this pattern of change was strikingly different to that shown by patients with acute inflammatory demyelinating polyneuropathy, suggesting that nerve excitability techniques may be useful in distinguishing acute-onset chronic inflammatory demyelinating polyneuropathy from acute inflammatory demyelinating polyneuropathy at the initial stage. © The Author (2014). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Lee, Ju-hyun; Kim, Tae-ho
2017-01-01
[Purpose] In this paper, hamstring stretching and nerve mobilization are conducted on patients with radicular lower back pain, and changes to pain levels, pressure thresholds, angles of knee joint extension, and disorder levels of lower back pain were studied. [Subjects and Methods] The subjects were divided into two groups: one group conducted hamstring stretches and was comprised of 6 male and 5 female subjects, and the other group received nerve mobilization treatment and was comprised of 5 male and 6 female subjects. [Results] Pain level and the disorder index of lower back pain were significantly alleviated after the intervention in both groups. Pressure threshold and angles of knee extension were significantly increased after the intervention in both groups. Comparing the two groups, the alleviation of pain was more significant in the nerve mobilization group. [Conclusion] Patients with radicular lower back pain showed significant differences in pain level, pressure threshold, knee extension angle, and disorder index of lower back pain for both the hamstring stretching group and nerve mobilization group after the treatment. Hamstring stretching and nerve mobilization can be usefully applied for the therapy of patients with radicular lower back pain. PMID:28931991
Taylor, Jude Matthew
2017-12-15
The contribution of resident endoneurial tissue macrophages versus recruited monocyte derived macrophages to demyelination and disease during Experimental Autoimmune Neuritis (EAN) was investigated using passive transfer of peripheral nerve myelin (PNM) specific serum antibodies or adoptive co-transfer of PNM specific T and B cells from EAN donors to leukopenic and normal hosts. Passive transfer of PNM specific serum antibodies or adoptive co-transfer of myelin specific T and B cells into leukopenic recipients resulted in a moderate reduction in nerve conduction block or in the disease severity compared to the normal recipients. This was despite at least a 95% decrease in the number of circulating mononuclear cells during the development of nerve conduction block and disease and a 50% reduction in the number of infiltrating endoneurial macrophages in the nerve lesions of the leukopenic recipients. These observations suggest that during EAN in Lewis rats actively induced by immunization with peripheral nerve myelin, phagocytic macrophages originating from the resident endoneurial population may be sufficient to engage in demyelination initiated by anti-myelin antibodies in this model. Copyright © 2017 Elsevier B.V. All rights reserved.
Stimulation of the human auditory nerve with optical radiation
NASA Astrophysics Data System (ADS)
Fishman, Andrew; Winkler, Piotr; Mierzwinski, Jozef; Beuth, Wojciech; Izzo Matic, Agnella; Siedlecki, Zygmunt; Teudt, Ingo; Maier, Hannes; Richter, Claus-Peter
2009-02-01
A novel, spatially selective method to stimulate cranial nerves has been proposed: contact free stimulation with optical radiation. The radiation source is an infrared pulsed laser. The Case Report is the first report ever that shows that optical stimulation of the auditory nerve is possible in the human. The ethical approach to conduct any measurements or tests in humans requires efficacy and safety studies in animals, which have been conducted in gerbils. This report represents the first step in a translational research project to initiate a paradigm shift in neural interfaces. A patient was selected who required surgical removal of a large meningioma angiomatum WHO I by a planned transcochlear approach. Prior to cochlear ablation by drilling and subsequent tumor resection, the cochlear nerve was stimulated with a pulsed infrared laser at low radiation energies. Stimulation with optical radiation evoked compound action potentials from the human auditory nerve. Stimulation of the auditory nerve with infrared laser pulses is possible in the human inner ear. The finding is an important step for translating results from animal experiments to human and furthers the development of a novel interface that uses optical radiation to stimulate neurons. Additional measurements are required to optimize the stimulation parameters.
Su, Juan; Zhang, Jing; Wang, Mingxin; Zhou, Huifang
2015-12-01
To explore the values of vestibular evoked myogenic potential (VEMP) in the diagnosis of vestibular nerve impairment in type 2 diabetes mellitus patients. Forty-two cases (84 ears) of diabetes mellitus patients and 42 cases (84 ears) normal subjects as the control group were enrolled from 2014 to 2015.Both the patients and normal subjects underwent conventional air-conducted ocular vestibular evoked myogenic potential (oVEMP) and cervical vestibular evoked myogenic potential (cVEMP) in bilateral ears.The results were compared between the patients and normal subjects. A commercially available software package, SPSS19.0, was used for statistical analysis. In 84 ears of the normal subjects, oVEMP was present in 70 ears, the educible rate was 83.3% (70/84). cVEMP was present in 74 ears, and the educible rate was 88.1% (74/84). In 84 ears of the diabetes mellitus patients, oVEMP was present in 49 ears, with the educible rate of 58.3% (49/84). cVEMP was present in 52 ears, with the educible rate of 61.9% (52/84). The educible rate in the control group was significantly higher than the diabetic group (oVEMP: χ(2)=12.71, P<0.05; cVEMP: χ(2)=15.37, P<0.05). In the diabetic group, the mean values of both oVEMP and cVEMP P1, N1 latencies were significantly longer when compared to the control group (P<0.05). No significantly statistical difference was found in oVEMP and cVEMP parameters (threshold, latency interval and amplitude) between groups (P>0.05). Vestibular nerve was impaired in diabetes mellitus patients in some degree. VEMP examinations could be useful in the diagnosis of vestibular nerve impairment in type 2 diabetes mellitus patients.
Paeoniae alba Radix Promotes Peripheral Nerve Regeneration
Huang, Kun-Shan; Lin, Jaung-Geng; Lee, Han-Chung; Tsai, Fuu-Jen; Bau, Da-Tian; Huang, Chih-Yang; Yao, Chun-Hsu; Chen, Yueh-Sheng
2011-01-01
The present study provides in vitro and in vivo evaluation of Paeoniae alba Radix (PR) on peripheral nerve regeneration. In the in vitro study, we found the PR caused a marked enhancement of the nerve growth factor-mediated neurite outgrowth from PC12 cells as well as their expression of growth associated protein 43 and synapsin I. In the in vivo study, silicone rubber chambers filled with the PR water extract were used to bridge a 10-mm sciatic nerve defect in rats. At the conclusion of 8 weeks, regenerated nerves in the PR groups, especially at 1.25 mg ml−1 had a higher rate of successful regeneration across the wide gap, relatively larger mean values of total nerve area, myelinated axon count and blood vessel number, and a significantly larger nerve conductive velocity compared to the control group (P < .05). These results suggest that the PR extract can be a potential nerve growth-promoting factor, being salutary in aiding the growth of injured peripheral nerve. PMID:19687191
Autologous transplantation with fewer fibers repairs large peripheral nerve defects
Deng, Jiu-xu; Zhang, Dian-yin; Li, Ming; Weng, Jian; Kou, Yu-hui; Zhang, Pei-xun; Han, Na; Chen, Bo; Yin, Xiao-feng; Jiang, Bao-guo
2017-01-01
Peripheral nerve injury is a serious disease and its repair is challenging. A cable-style autologous graft is the gold standard for repairing long peripheral nerve defects; however, ensuring that the minimum number of transplanted nerve attains maximum therapeutic effect remains poorly understood. In this study, a rat model of common peroneal nerve defect was established by resecting a 10-mm long right common peroneal nerve. Rats receiving transplantation of the common peroneal nerve in situ were designated as the in situ graft group. Ipsilateral sural nerves (10–30 mm long) were resected to establish the one sural nerve graft group, two sural nerves cable-style nerve graft group and three sural nerves cable-style nerve graft group. Each bundle of the peroneal nerve was 10 mm long. To reduce the barrier effect due to invasion by surrounding tissue and connective-tissue overgrowth between neural stumps, small gap sleeve suture was used in both proximal and distal terminals to allow repair of the injured common peroneal nerve. At three months postoperatively, recovery of nerve function and morphology was observed using osmium tetroxide staining and functional detection. The results showed that the number of regenerated nerve fibers, common peroneal nerve function index, motor nerve conduction velocity, recovery of myodynamia, and wet weight ratios of tibialis anterior muscle were not significantly different among the one sural nerve graft group, two sural nerves cable-style nerve graft group, and three sural nerves cable-style nerve graft group. These data suggest that the repair effect achieved using one sural nerve graft with a lower number of nerve fibers is the same as that achieved using the two sural nerves cable-style nerve graft and three sural nerves cable-style nerve graft. This indicates that according to the ‘multiple amplification’ phenomenon, one small nerve graft can provide a good therapeutic effect for a large peripheral nerve defect. PMID:29323049
Physiological and pharmacologic aspects of peripheral nerve blocks
Vadhanan, Prasanna; Tripaty, Debendra Kumar; Adinarayanan, S.
2015-01-01
A successful peripheral nerve block not only involves a proper technique, but also a thorough knowledge and understanding of the physiology of nerve conduction and pharmacology of local anesthetics (LAs). This article focuses on what happens after the block. Pharmacodynamics of LAs, underlying mechanisms of clinically observable phenomena such as differential blockade, tachyphylaxis, C fiber resistance, tonic and phasic blockade and effect of volume and concentration of LAs. Judicious use of additives along with LAs in peripheral nerve blocks can prolong analgesia. An entirely new group of drugs-neurotoxins has shown potential as local anesthetics. Various methods are available now to prolong the duration of peripheral nerve blocks. PMID:26330722
Bauché, Stéphanie; Boerio, Delphine; Davoine, Claire-Sophie; Bernard, Véronique; Stum, Morgane; Bureau, Cécile; Fardeau, Michel; Romero, Norma Beatriz; Fontaine, Bertrand; Koenig, Jeanine; Hantaï, Daniel; Gueguen, Antoine; Fournier, Emmanuel; Eymard, Bruno; Nicole, Sophie
2013-12-01
Schwartz-Jampel syndrome (SJS) is a recessive disorder with muscle hyperactivity that results from hypomorphic mutations in the perlecan gene, a basement membrane proteoglycan. Analyses done on a mouse model have suggested that SJS is a congenital form of distal peripheral nerve hyperexcitability resulting from synaptic acetylcholinesterase deficiency, nerve terminal instability with preterminal amyelination, and subtle peripheral nerve changes. We investigated one adult patient with SJS to study this statement in humans. Perlecan deficiency due to hypomorphic mutations was observed in the patient biological samples. Electroneuromyography showed normal nerve conduction, neuromuscular transmission, and compound nerve action potentials while multiple measures of peripheral nerve excitability along the nerve trunk did not detect changes. Needle electromyography detected complex repetitive discharges without any evidence for neuromuscular transmission failure. The study of muscle biopsies containing neuromuscular junctions showed well-formed post-synaptic element, synaptic acetylcholinesterase deficiency, denervation of synaptic gutters with reinnervation by terminal sprouting, and long nonmyelinated preterminal nerve segments. These data support the notion of peripheral nerve hyperexcitability in SJS, which would originate distally from synergistic actions of peripheral nerve and neuromuscular junction changes as a result of perlecan deficiency. Copyright © 2013 Elsevier B.V. All rights reserved.
HIRASAWA, Shun; SHIMIZU, Miki; MARUI, Yuumi; KISHIMOTO, Miori; OKUNO, Seiichi
2014-01-01
We designed a new method of measuring the length of the ulnar nerve and determining standard values for F-wave parameters of the ulnar nerve in clinically normal beagles. Nerve length must be precisely measured to determine F-wave latency and conduction velocity. The length of the forelimb has served as the length of the ulnar nerve for F-wave assessments, but report indicates that F-wave latency is proportional to the length of the pathway traveled by nerve impulses. Therefore, we measured the surface distance from a stimulus point to the spinous process of the first thoracic vertebra (nerve length 1) and the anterior horn of the scapula (nerve length 2) as landmarks through the olecranon and the shoulder blade acromion. The correlation coefficients between the shortest F-wave latency and the length of nerves 1, 2 or the forelimb were 0.61, 0.7 and 0.58. Nerve length 2 generated the highest value. Furthermore, the anterior horn of the scapula was easily palpated in any dog regardless of well-fed body. We concluded that nerve length 2 was optimal for measuring the length of the ulnar nerve. PMID:25649942
Ocular complications associated with local anesthesia administration in dentistry.
Boynes, Sean G; Echeverria, Zydnia; Abdulwahab, Mohammad
2010-10-01
The most widely used method for controlling pain during dental procedures is the intraoral administration of local anesthetics in close proximity to a specific nerve or fiber to obtund nerve conduction. The most commonly anesthetized nerves in dentistry are branches or nerve trunks associated with the maxillary and mandibular divisions of the trigeminal nerve (cranial nerve V). However, other nerves may be inadvertently affected by intraoral local anesthesia injections, resulting in anesthetic complications of structures far from the oral cavity. Practitioners should be aware of potential ocular complications following intraoral injections in dentistry. These complications include oculomotor paralysis and vision loss. The knowledge of these conditions and their potential cause should alert the dentist to the importance of appropriate injection techniques and an understanding of management protocol. Copyright © 2010 Elsevier Inc. All rights reserved.
Montserrat-Bosch, Marta; Nogueira-Magalhães, Pedro; Arnabat-Dominguez, Josep; Valmaseda-Castellón, Eduard; Gay-Escoda, Cosme
2014-01-01
Objectives: To compare the efficacy and complication rates of two different techniques for inferior alveolar nerve blocks (IANB). Study Design: A randomized, triple-blind clinical trial comprising 109 patients who required lower third molar removal was performed. In the control group, all patients received an IANB using the conventional Halsted technique, whereas in the experimental group, a modified technique using a more inferior injection point was performed. Results: A total of 100 patients were randomized. The modified technique group showed a significantly higher onset time in the lower lip and chin area, and was frequently associated to a lingual electric discharge sensation. Three failures were recorded, 2 of them in the experimental group. No relevant local or systemic complications were registered. Conclusions: Both IANB techniques used in this trial are suitable for lower third molar removal. However, performing an inferior alveolar nerve block in a more inferior position (modified technique) extends the onset time, does not seem to reduce the risk of intravascular injections and might increase the risk of lingual nerve injuries. Key words:Dental anesthesia, inferior alveolar nerve block, lidocaine, third molar, intravascular injection. PMID:24608204
Clitoral Epidermal Inclusion Cyst Resection With Intraoperative Sensory Nerve Mapping Technique.
Wu, Cindy; Damitz, Lynn; Karrat, Kimberly M; Mintz, Alice; Zolnoun, Denniz
2016-01-01
Despite the ever increasing popularity of labial and clitoral surgeries, the best practices and long-term effects of reconstructive procedures in these regions remain unknown. This is particularly noteworthy because the presentation of nerve-related symptoms may be delayed up to a year. Despite the convention that these surgical procedures are low risk, little is known about the best practices that may reduce the postoperative complications as a result of these reconstructive surgeries. We describe a preoperative sensory mapping technique in the context of a symptomatic inclusion cyst in the clitoral region. This technique delineates anatomical and functional regions innervated by the dorsal clitoral nerve while minimizing the vascular watershed area in the midline. A prototypical case of a patient with a clitoral mass is discussed with clinical history and surgical approach. Prior to surgical excision, the dorsal clitoral nerve distribution was mapped in order to avoid a surgical incision in this sensual zone. In our practice, preoperative sensory mapping is a clinically useful planning tool that requires minimal instrumentation and no additional operating time. Sensory mapping allows identification of the functional zone innervated by the dorsal clitoral nerve, which can aid in minimizing damage to the area.
NASA Astrophysics Data System (ADS)
Dreisewerd, Klaus; Kingston, Robert; Geraerts, Wijnand P. M.; Li, Ka Wan
1997-12-01
Matrix-assisted laser desorption mass spectrometry (MALDI-MS) was performed directly on a small piece of single penis nerve of the pond snail, Lymnaea stagnalis, and reveals the presence of complex peptide profiles, including many hitherto undescribed peptides. Two of the peptides have molecular weights corresponding exactly to the previously described Lymnaea small cardioactive peptides (SCP) A and B. We confirmed their identities by structural characterization of the two peptides directly from a single penis nerve by matrix-assisted laser desorption ionization high-energy collision tandem MS analysis. MALDI-MS of nervous tissues also demonstrates that a cluster of central neurons, which send their axons to the penis nerve, contain the two peptides. As the penis nerve is the nerve that innervates the penis complex, we propose that the peptides are involved in the modulation of male copulatory processes. A bioassay indeed showed that the peptides increase the contraction frequency of the vas deference in a dose-dependent manner. The results demonstrate the potential of direct MALDI-MS analysis of nervous tissue to complement or substitute conventional biochemical techniques for the identification and localization of neuropeptides.
Skaribas, Ioannis; Calvillo, Octavio; Delikanaki-Skaribas, Evangelia
2011-05-10
Occipital peripheral nerve stimulation is an interventional pain management therapy that provides beneficial results in the treatment of refractory chronic occipital neuralgia. Herein we present a first-of-its-kind case study of a patient with neurofibromatosis type 1 and bilateral occipital neuralgia treated with occipital peripheral nerve stimulation. A 42-year-old Caucasian woman presented with bilateral occipital neuralgia refractory to various conventional treatments, and she was referred for possible treatment with occipital peripheral nerve stimulation. She was found to be a suitable candidate for the procedure, and she underwent implantation of two octapolar stimulating leads and a rechargeable, programmable, implantable generator. The intensity, severity, and frequency of her symptoms resolved by more than 80%, but an infection developed at the implantation site two months after the procedure that required explantation and reimplantation of new stimulating leads three months later. To date she continues to experience symptom resolution of more than 60%. These results demonstrate the significance of peripheral nerve stimulation in the management of refractory occipital neuralgias in patients with neurofibromatosis type 1 and the possible role of neurofibromata in the development of occipital neuralgia in these patients.
NASA Astrophysics Data System (ADS)
Xia, Wenfeng; West, Simeon J.; Nikitichev, Daniil I.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.
2016-03-01
Accurate identification of tissue structures such as nerves and blood vessels is critically important for interventional procedures such as nerve blocks. Ultrasound imaging is widely used as a guidance modality to visualize anatomical structures in real-time. However, identification of nerves and small blood vessels can be very challenging, and accidental intra-neural or intra-vascular injections can result in significant complications. Multi-spectral photoacoustic imaging can provide high sensitivity and specificity for discriminating hemoglobin- and lipid-rich tissues. However, conventional surface-illumination-based photoacoustic systems suffer from limited sensitivity at large depths. In this study, for the first time, an interventional multispectral photoacoustic imaging (IMPA) system was used to image nerves in a swine model in vivo. Pulsed excitation light with wavelengths in the ranges of 750 - 900 nm and 1150 - 1300 nm was delivered inside the body through an optical fiber positioned within the cannula of an injection needle. Ultrasound waves were received at the tissue surface using a clinical linear array imaging probe. Co-registered B-mode ultrasound images were acquired using the same imaging probe. Nerve identification was performed using a combination of B-mode ultrasound imaging and electrical stimulation. Using a linear model, spectral-unmixing of the photoacoustic data was performed to provide image contrast for oxygenated and de-oxygenated hemoglobin, water and lipids. Good correspondence between a known nerve location and a lipid-rich region in the photoacoustic images was observed. The results indicate that IMPA is a promising modality for guiding nerve blocks and other interventional procedures. Challenges involved with clinical translation are discussed.
Hokkoku, Keiichi; Matsukura, Kiyoshi; Uchida, Yudai; Kuwabara, Midori; Furukawa, Yuichi; Tsukamoto, Hiroshi; Hatanaka, Yuki; Sonoo, Masahiro
2017-10-01
In chronic inflammatory demyelinating polyneuropathy (CIDP), exclusion of secondary axonal degeneration is challenging with conventional methods such as nerve conduction study (NCS), needle electromyography, and nerve biopsy. Increased echo intensity (EI) and decreased muscle thickness (MT) identified on muscle ultrasound (MUS) examination represent muscle denervation due to axonal degeneration in neurogenic disorders, suggesting MUS as a new tool to detect secondary axonal degeneration in patients with CIDP. EI and MT of abductor pollicis brevis, abductor digiti minimi, and first dorsal interosseous muscles were measured in 16 CIDP patients. Raw values were converted into z -scores using data from 60 normal controls (NCs). Six of 45 muscles showed abnormally high EI and low MT, suggesting denervation following secondary axonal degeneration. These six muscles belonged to two patients with long disease history, unresponsiveness to treatment, and long interval from onset to initial therapy. There were no significant differences in EI and MT ( p = .23 and .67, respectively) between the CIDP and NC groups, although NCS results revealed obvious demyelinating abnormalities in all CIDP patients, suggesting the fact that muscle structures will be preserved, and EI and MT will not change unless secondary axonal degeneration occurs in CIDP. MUS is a promising tool for evaluating secondary axonal degeneration in patients with CIDP.
Effects of a laser acupuncture therapy on treating pain
NASA Astrophysics Data System (ADS)
Wong, Wai-on; Xiao, Shaojun; Ip, Wing-Yuk; Guo, Xia
2001-10-01
Laser acupuncture (LA) has been utilized as a combined approach of Chinese traditional acupuncture and low-level laser therapy since its emergence in 1973. Its mechanisms are not well understood and the standardization of clinical protocols has not been established. In this study, we used a diode laser to irradiate on four acupuncture points for normal subjects to investigate the effect of LA. For each point, the irradiation lasted for three minutes. The median nerve conduction velocity was measured within a 30 minutes interval at day 1, day 5, and day 10 respectively. Patients with chronic carpal tunnel syndrome (CTS) were given LA therapy for three stages at most with a one-week interval between two stages. Treatment outcome measurements included patients' subjective feedback (McGill pain questionnaire, VAS) and objective measurements (physical examination, kinesiological properties and NCSs). It was a randomized single-blind controlled trial. For normal subjects, motor nerve fiber was sensitive to LA and the motor conduction velocity was decreased very significantly (p < 0.001). Besides, it was found that LA resulted that sensory nerve conduction velocity was decreased significantly when it was measured 30 minutes after the subject had received LA application. For CTS patients, the outcomes except pinch test indicated that LA could improve patient's conduction. These results suggested that LA could cause the change of nerve conduction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burke, J.P.; Fenton, M.R.
1991-03-15
This study was designed to assess the effects of diets high in fish and corn oil on peripheral nerve metabolism in streptozotocin (STZ) induced diabetic rats. A type I diabetic state was induced in female Sprague-Dawley rats by injection of STZ. Animals were divided into three dietary groups; normal rat chow, high corn oil diet and high fish oil diet. After 4 weeks animals were analyzed for nerve conduction velocity, bled and then sacrificed. Sciatic nerves were removed, processed and several biochemical parameters determined. Plasma zinc levels were elevated in the STZ normal chow group compared to non-diabetic controls. Bothmore » corn oil and fish oil diets tended to eliminate the rise in plasma zinc. Differences in subcellular distribution of zinc in sciatic nerves were also observed. Normal chow STZ animals displayed a 20% decrease in nerve conduction velocity compared to control. Dietary supplementation with either fish or corn oil seemed to ameliorate these effects. Biochemical analysis of Na{sup +}-K{sup +}-ATPase and protein kinase C revealed a decrease in activity in normal chow animals compared to control groups. Again, dietary intervention with either fish or corn oil seemed to return these activities back to normal. The results suggest a link between zinc metabolism and peripheral nerve metabolism which can be modified by dietary intervention.« less
Hurtado, Erica; Cilleros, Víctor; Just, Laia; Simó, Anna; Nadal, Laura; Tomàs, Marta; Garcia, Neus; Lanuza, Maria A; Tomàs, Josep
2017-01-01
Conventional protein kinase C βI (cPKCβI) is a conventional protein kinase C (PKC) isoform directly involved in the regulation of neurotransmitter release in the neuromuscular junction (NMJ). It is located exclusively at the nerve terminal and both synaptic activity and muscle contraction modulate its protein levels and phosphorylation. cPKCβI molecular maturation includes a series of phosphorylation steps, the first of which is mediated by phosphoinositide-dependent kinase 1 (PDK1). Here, we sought to localize PDK1 in the NMJ and investigate the hypothesis that synaptic activity and muscle contraction regulate in parallel PDK1 and cPKCβI phosphorylation in the membrane fraction. To differentiate the presynaptic and postsynaptic activities, we abolished muscle contraction with μ-conotoxin GIIIB (μ-CgTx-GIIIB) in some experiments before stimulation of the phrenic nerve (1 Hz, 30 min). Then, we analyzed total and membrane/cytosol fractions of skeletal muscle by Western blotting. Results showed that PDK1 is located exclusively in the nerve terminal of the NMJ. After nerve stimulation with and without coincident muscle contraction, total PDK1 and phosphorylated PDK1 (pPDK1) protein levels remained unaltered. However, synaptic activity specifically enhanced phosphorylation of PDK1 in the membrane, an important subcellular location for PDK1 function. This increase in pPDK1 coincides with a significant increase in the phosphorylation of its substrate cPKCβI also in the membrane fraction. Moreover, muscle contraction maintains PDK1 and pPDK1 but increases cPKCβI protein levels and its phosphorylation. Thus, even though PDK1 activity is maintained, pcPKCβI levels increase in concordance with total cPKCβI. Together, these results indicate that neuromuscular activity could induce the membrane targeting of pPDK1 in the nerve terminal of the NMJ to promote the phosphorylation of the cPKCβI, which is involved in ACh release.
Hurtado, Erica; Cilleros, Víctor; Just, Laia; Simó, Anna; Nadal, Laura; Tomàs, Marta; Garcia, Neus; Lanuza, Maria A.; Tomàs, Josep
2017-01-01
Conventional protein kinase C βI (cPKCβI) is a conventional protein kinase C (PKC) isoform directly involved in the regulation of neurotransmitter release in the neuromuscular junction (NMJ). It is located exclusively at the nerve terminal and both synaptic activity and muscle contraction modulate its protein levels and phosphorylation. cPKCβI molecular maturation includes a series of phosphorylation steps, the first of which is mediated by phosphoinositide-dependent kinase 1 (PDK1). Here, we sought to localize PDK1 in the NMJ and investigate the hypothesis that synaptic activity and muscle contraction regulate in parallel PDK1 and cPKCβI phosphorylation in the membrane fraction. To differentiate the presynaptic and postsynaptic activities, we abolished muscle contraction with μ-conotoxin GIIIB (μ-CgTx-GIIIB) in some experiments before stimulation of the phrenic nerve (1 Hz, 30 min). Then, we analyzed total and membrane/cytosol fractions of skeletal muscle by Western blotting. Results showed that PDK1 is located exclusively in the nerve terminal of the NMJ. After nerve stimulation with and without coincident muscle contraction, total PDK1 and phosphorylated PDK1 (pPDK1) protein levels remained unaltered. However, synaptic activity specifically enhanced phosphorylation of PDK1 in the membrane, an important subcellular location for PDK1 function. This increase in pPDK1 coincides with a significant increase in the phosphorylation of its substrate cPKCβI also in the membrane fraction. Moreover, muscle contraction maintains PDK1 and pPDK1 but increases cPKCβI protein levels and its phosphorylation. Thus, even though PDK1 activity is maintained, pcPKCβI levels increase in concordance with total cPKCβI. Together, these results indicate that neuromuscular activity could induce the membrane targeting of pPDK1 in the nerve terminal of the NMJ to promote the phosphorylation of the cPKCβI, which is involved in ACh release. PMID:28890686
Nerve Conduction in the Pre-Medical Physics Course
ERIC Educational Resources Information Center
Hobbie, Russell K.
1973-01-01
Reviews properties of nerves, analogous networks in propagation of electrical signals in axons, and regenerative changes in membrane permeability due to propagation of the action potential, which can be explained in the noncalculus physics course. (CC)
Combining SBR systems for chemical and biological treatment: the destruction of the nerve agent VX.
Irvine, R L; Haraburda, S S; Galbis-Reig, C
2004-01-01
The US Army is pilot testing the neutralization of VX nerve agent stockpiled at Newport, Indiana using caustic hydrolysis in a Sequencing Batch Reactor (SBR). The resulting hydrolysate was tested at the bench-scale for treatment with activated sludge biodegradation in two distinct studies, one in the SBR and another, in the PACT process. The feed to both biological systems was pretreated to enhance the biodegradability of the hydrolysis products. Both biodegradation studies demonstrated that the hydrolysate could easily meet the Chemical Weapons Convention treaty and US environmental regulations following pretreatment.
Cnidarian Nerve Nets and Neuromuscular Efficiency.
Satterlie, Richard A
2015-12-01
Cnidarians are considered "nerve net animals" even though their nervous systems include various forms of condensation and centralization. Yet, their broad, two-dimensional muscle sheets are innervated by diffuse nerve nets. Do the motor nerve nets represent a primitive organization of multicellular nervous systems, do they represent a consequence of radial symmetry, or do they offer an efficient way to innervate a broad, two-dimensional muscle sheet, in which excitation of the muscle sheet can come from multiple sites of initiation? Regarding the primitive nature of cnidarian nervous systems, distinct neuronal systems exhibit some adaptations that are well known in higher animals, such as the use of oversized neurons with increased speed of conduction, and condensation of neurites into nerve-like tracts. A comparison of neural control of two-dimensional muscle sheets in a mollusc and jellyfish suggests that a possible primitive feature of cnidarian neurons may be a lack of regional specialization into conducting and transmitting regions. © The Author 2015. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.
Soft Graphene Nanofibers Designed for the Acceleration of Nerve Growth and Development.
Feng, Zhang-Qi; Wang, Ting; Zhao, Bin; Li, Jiacheng; Jin, Lin
2015-11-04
Soft graphene nanofibers with recoverable electrical conductivity and excellent physicochemical stability are prepared by a controlled assembly technique. By using the soft graphene nanofibers for cellular electrical stimulation, the common inhibitory effect of long-term electrical stimulation on nerve growth and development is avoided, which usually happens with traditional 2D conductive materials. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
N-hexane neuropathy with vertigo and cold allodynia in a silk screen printer: A case study.
Pradhan, Sunil; Tandon, Ruchika
2015-01-01
N-hexane neuropathy is an occupational disease caused by exposure to n-hexane, which is used as a solvent in silk screen printing. Here, we describe a 35-year-old man, a silk screen printer by profession, who presented with dizziness, distal swelling of both lower limbs for 10 months and tingling and burning sensation in both feet for 9.5 months along with cold allodynia. The patient had normal results of a motor and sensory system examination, apart from an impaired temperature sense. Nerve conduction tests showed a conduction block in bilateral common peroneal nerves and absence of conduction in bilateral sural nerves. These symptoms resolved when further exposure to n-hexane was ceased but cold allodynia remained. Thus, cold allodynia and impaired temperature sense can be a manifestation of n-hexane neuropathy. Hence, abnormalities on nerve conduction studies can be detected in n-hexane neuropathy patients, even before clinical examination detects any such abnormalities. In the case of the patients presenting with sensory motor neuropathy, history of occupational exposure to n-hexane becomes important, as the sooner the disease is detected, the better the chances of recovery. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Shi, Miao; Qi, Hengtao; Ding, Hongyu; Chen, Feng; Xin, Zhaoqin; Zhao, Qinghua; Guan, Shibing; Shi, Hao
2018-01-01
Abstract This study aims to evaluate the value of electrophysiological examination and high frequency ultrasonography in the differential diagnosis of radial nerve torsion and radial nerve compression. Patients with radial nerve torsion (n = 14) and radial nerve compression (n = 14) were enrolled. The results of neurophysiological and high frequency ultrasonography were compared. Electrophysiological examination and high-frequency ultrasonography had a high diagnostic rate for both diseases with consistent results. Of the 28 patients, 23 were positive for electrophysiological examination, showing decreased amplitude and decreased conduction velocity of radial nerve; however, electrophysiological examination cannot distinguish torsion from compression. A total of 27 cases showed positive in ultrasound examinations among all 28 cases. On ultrasound images, the nerve was thinned at torsion site whereas thickened at the distal ends of torsion. The diameter and cross-sectional area of torsion or compression determined the nerve damage, and ultrasound could locate the nerve injury site and measure the length of the nerve. Electrophysiological examination and high-frequency ultrasonography can diagnose radial neuropathy, with electrophysiological examination reflecting the neurological function, and high-frequency ultrasound differentiating nerve torsion from compression. PMID:29480857
Extracranial schwannoma in the carotid space: A retrospective review of 91 cases.
Zheng, Xiaoke; Guo, Kai; Wang, Hongshi; Li, Duanshu; Wu, Yi; Ji, Qinghai; Shen, Qiang; Sun, Tuanqi; Xiang, Jun; Zeng, Wei; Chen, Yaling; Wang, Zhuoying
2017-01-01
Schwannomas of the vagus nerve and cervical sympathetic nerve are rare; hence, only limited information exists regarding their diagnosis and clinical management. We conducted a retrospective review of the clinical features, imaging studies, and treatment results of patients with schwannoma of the vagus nerve and schwannoma of the sympathetic nerve. Of 91 patients, 91% (n = 83) were preoperatively diagnosed with schwannoma tumors. Using the hyoid bone as an anatomic landmark, the location of the schwannoma of the vagus nerve in the carotid space was significantly different to the location of schwannoma of the sympathetic nerve (p = .003). Although 52 of the 76 patients followed up (68%) had postoperative nerve weaknesses, 13 patients (50%) and 14 patients (53.8%), respectively, fully recovered from schwannoma of the vagus nerve and schwannoma of the sympathetic nerve. In the carotid space, schwannomas of the vagus nerve are usually located below the hyoid bone, whereas schwannomas of the sympathetic nerve more commonly arise from the suprahyoid compartment. Accurate preoperative diagnosis and the intracapsular enucleation surgical approach decreased the incidence of postoperative morbidity. © 2016 Wiley Periodicals, Head Neck 39: 42-47, 2017. © 2016 Wiley Periodicals, Inc.
Gmeiner, Matthias; Topakian, Raffi; Göschl, Manuel; Wurm, Sarah; Holzinger, Anita; van Ouwerkerk, Willem J R; Holl, Kurt
2015-09-01
An accessory to suprascapular nerve (XIN-SSN) transfer is considered in patients with obstetric brachial plexus lesion who fail to recover active shoulder external rotation. The aim of this study was to evaluate the quality of extraplexal suprascapular nerve neurotization and to perform a detailed analysis of the infraspinatus muscle (IM) and shoulder external rotation. A XIN-SSN transfer was performed in 14 patients between 2000 and 2007. Patients had been operated at the age of 3.7 ± 2.8 years. Follow-up examinations were conducted up to 8.5 ± 2.5 years. Magnetic resonance imaging was performed to investigate muscle trophism. Fatty muscle degeneration of the IM was classified according to the Goutallier classification. We conducted nerve conduction velocity studies of the suprascapular nerve and needle electromyography of the IM to assess pathologic spontaneous activity and interference patterns. Active glenohumeral shoulder external rotation and global shoulder function were evaluated using the Mallet score. Postoperatively, growth of the IM increased equally on the affected and unaffected sides, although significant differences of muscle thickness persisted over time. There was only grade 1 or 2 fatty degeneration pre- and postoperatively. Electromyography of the IM revealed a full interference pattern in all except one patient, and there was no pathological spontaneous activity. Glenohumeral external rotation as well as global shoulder function increased significantly. Our results indicate that the anastomosis after XIN-SSN transfer is functional and that successful reinnervation of the infraspinatus muscle may enable true glenohumeral active external rotation.
Zhu, Shuang; Liu, Jianghui; Zheng, Canbin; Gu, Liqiang; Zhu, Qingtang; Xiang, Jianping; He, Bo; Zhou, Xiang; Liu, Xiaolin
2017-08-01
Human acellular nerve allografts have been increasingly applied in clinical practice. This study was undertaken to investigate the functional outcomes of nerve allograft reconstruction for nerve defects in the upper extremity. A total of 64 patients from 13 hospitals were available for this follow-up study after nerve repair using human acellular nerve allografts. Sensory and motor recovery was examined according to the international standards for motor and sensory nerve recovery. Subgroup analysis and logistic regression analysis were conducted to identify the relationship between the known factors and the outcomes of nerve repair. Mean follow-up time was 355 ± 158 (35-819) days; mean age was 35 ± 11 (14-68) years; average nerve gap length was 27 ± 13 (10-60) mm; no signs of infection, tissue rejection or extrusion were observed among the patients; 48/64 (75%) repaired nerves experienced meaningful recovery. Univariate analysis showed that site and gap length significantly influenced prognosis after nerve repair using nerve grafts. Delay had a marginally significant relationship with the outcome. A multivariate logistic regression model revealed that gap length was an independent predictor of nerve repair using human acellular nerve allografts. The results indicated that the human acellular nerve allograft facilitated safe and effective nerve reconstruction for nerve gaps 10-60 mm in length in the hand and upper extremity. Factors such as site and gap length had a statistically significant influence on the outcomes of nerve allograft reconstruction. Gap length was an independent predictor of nerve repair using human acellular nerve allografts. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Hanna, Amgad S
2017-04-01
Meralgia paresthetica causes pain in the anterolateral thigh. Most surgical procedures involve nerve transection or decompression. We conducted a cadaveric study to determine the feasibility of lateral femoral cutaneous nerve (LFCN) transposition. In three cadavers, the LFCN was exposed in the thigh and retroperitoneum. The two layers of the LFCN canal superficial and deep to the nerve were opened. The nerve was then mobilized medially away from the ASIS, by cutting the septum medial to sartorius. It was possible to mobilize the nerve for 2 cm medial to the ASIS. The nerve acquired a much straighter course with less tension. A new technique of LFCN transposition is presented here as an anatomical feasibility study. The surgical technique is based on the new understanding of the LFCN canal. Clin. Anat. 30:409-412, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
MICROCHIP ENZYMATIC ASSAY OF ORGANOPHOSPHATE NERVE AGENTS. (R830900)
An on-chip enzymatic assay for screening organophosphate (OP) nerve agents, based on a pre-column reaction of organophosphorus hydrolase (OPH), electrophoretic separation of the phosphonic acid products, and their contactless-conductivity detection, is described. Factors affec...
Askar, Ibrahím; Sabuncuoglu, Bízden Tavíl
2002-01-01
Neurorraphy, conventional nerve grafting technique, and artificial nerve conduits are not enough for repair in severe injuries of peripheral nerves, especially when there is separation of motor nerve from muscle tissue. In these nerve injuries, reinnervation is indicated for neurotization. The distal end of a peripheral nerve is divided into fascicles and implanted into the aneural zone of target muscle tissue. It is not known how deeply fascicles should be implanted into muscle tissue. A comparative study of superficial and deep implantation of separated motor nerve into muscle tissue is presented in the gastrocnemius muscle of rabbits. In this experimental study, 30 white New Zealand rabbits were used and divided into 3 groups of 10 rabbits each. In the first group (controls, group I), only surgical exposure of the gastrocnemius muscle and motor nerve (tibial nerve) was done without any injury to nerves. In the superficial implantation group (group II), tibial nerves were separated and divided into their own fascicles. These fascicles were implanted superficially into the lateral head of gastrocnemius muscle-aneural zone. In the deep implantation group (group III), the tibial nerves were separated and divided into their own fascicles. These fascicles were implanted around the center of the muscle mass, into the lateral head of the gastrocnemius muscle-aneural zone. Six months later, histopathological changes and functional recovery of the gastrocnemius muscle were investigated. Both experimental groups had less muscular weight than in the control group. It was found that functional recovery was achieved in both experimental groups, and was better in the superficial implantation group than the deep implantation group. EMG recordings revealed that polyphasic and late potentials were frequently seen in both experimental groups. Degeneration and regeneration of myofibrils were observed in both experimental groups. New motor end-plates were formed in a scattered manner in both experimental groups. However, they were more dense in the superficial implantation group than the deep implantation group. It was concluded that superficial implantation has a more powerful contractile capacity than that of deep implantation. We believe that this might arise from the high activity of glycolytic enzymes in peripheral muscle fibers of gastrocnemius muscle, decrease in insufficient intramuscular guidance apparatus, and intramuscular microneuroma formation at the insufficient neuromuscular junction since the motor nerve had less route to muscle fibers. Copyright 2002 Wiley-Liss, Inc.
Electrophysiological measurements of diabetic peripheral neuropathy: A systematic review.
Shabeeb, Dheyauldeen; Najafi, Masoud; Hasanzadeh, Gholamreza; Hadian, Mohammed Reza; Musa, Ahmed Eleojio; Shirazi, Alireza
2018-03-28
Peripheral neuropathy is one of the main complications of diabetes mellitus. One of the features of diabetic nerve damage is abnormality of sensory and motor nerve conduction study. An electrophysiological examination can be reproduced and is also a non-invasive approach in the assessment of peripheral nerve function. Population-based and clinical studies have been conducted to validate the sensitivity of these methods. When the diagnosis was based on clinical electrophysiological examination, abnormalities were observed in all patients. In this research, using a review design, we reviewed the issue of clinical electrophysiological examination of diabetic peripheral neuropathy in articles from 2008 to 2017. For this purpose, PubMed, Scopus and Embase databases of journals were used for searching articles. The researchers indicated that diabetes (both types) is a very disturbing health issue in the modern world and should be given serious attention. Based on conducted studies, it was demonstrated that there are different procedures for prevention and treatment of diabetes-related health problems such as diabetic polyneuropathy (DPN). The first objective quantitative indication of the peripheral neuropathy is abnormality of sensory and motor nerve conduction tests. Electrophysiology is accurate, reliable and sensitive. It can be reproduced and also is a noninvasive approach in the assessment of peripheral nerve function. The methodological review has found that the best method for quantitative indication of the peripheral neuropathy compared with all other methods is clinical electrophysiological examination. For best results, standard protocols such as temperature control and equipment calibration are recommended. Copyright © 2018. Published by Elsevier Ltd.
Rajabally, Yusuf A; Wong, Siew L
2012-03-01
We describe a patient presenting with progressive upper limb numbness and sensory ataxia of the 4 limbs. Motor nerve conduction studies were completely normal. Sensory electrophysiology showed reduced/absent upper limb sensory action potentials (SAPs). In the lower limbs, SAPs were mostly normal. Sensory conduction velocities were normal. Forearm sensory conduction blocks were present for both median nerves on antidromic testing. The maximal recordable sural SAP was preserved in comparison to maximal recordable radial SAP, consistent with an "abnormal radial normal sural" pattern. Somatosensory evoked potentials were unrecordable for tibial and median nerves. Cerebrospinal fluid protein was raised (0.99 g/L). The patient worsened on oral corticosteroids but subsequently made substantial functional recovery on intravenous immunoglobulins. This case is different to those previously reported of sensory chronic inflammatory demyelinating polyradiculoneuropathy, given its exclusive sensory electrophysiologic presentation, presence of predominant upper limb reduced sensory amplitudes, and detection of sensory conduction blocks. These electrophysiologic features were of paramount importance in establishing diagnosis and effective therapy.
Bolt, David M; Burba, Daniel J; Hubert, Jeremy D; Strain, George M; Hosgood, Giselle L; Henk, William G; Cho, Doo-Youn
2004-12-01
To determine functional and morphologic changes in palmar digital nerves after nonfocused extracorporeal shock wave (ESW) treatment in horses. 6 horses. The medial and lateral palmar digital nerves of the left forelimb were treated with nonfocused ESWs. The medial palmar digital nerve of the right forelimb served as a nontreated control nerve. At 3, 7, and 35 days after treatment, respectively, 2 horses each were anesthetized and nerves were surgically exposed. Sensory nerve conduction velocities (SNCVs) of treated and control nerves were recorded, after which palmar digital neurectomies were performed. Morphologic changes in nerves were assessed via transmission electron microscopy. Significantly lower SNCV in treated medial and lateral nerves, compared with control nerves, was found 3 and 7 days after treatment. A significantly lower SNCV was detected in treated medial but not lateral nerves 35 days after treatment. Transmission electron microscopy of treated nerves revealed disruption of the myelin sheath with no evidence of damage to Schwann cell bodies or axons, 3, 7, and 35 days after treatment. Nonfocused ESW treatment of the metacarpophalangeal area resulted in lower SNCV in palmar digital nerves. This effect likely contributes to the post-treatment analgesia observed in horses and may result in altered peripheral pain perception. Horses with preexisting lesions may be at greater risk of sustaining catastrophic injuries when exercised after treatment.
Zotova, Elena G; Christ, George J; Zhao, Weixin; Tar, Moses; Kuppam, Srini D; Arezzo, Joseph C
2007-01-01
The effects of fidarestat, an aldose reductase inhibitor (ARI), were assessed on nerve conduction velocity (NCV) in somatic nerves and on multiple measures of bladder function in rats made hyperglycemic with streptozotocin (STZ) and in age-matched controls. Nerve conduction velocity was recorded at baseline and at 10, 20, 30, and 50 days after confirmation of the STZ-induced hyperglycemia in all rats (N=47); bladder function was assessed in a representative subset of rats (N=20) at Day 50. Caudal NCV was markedly slowed by STZ, and this effect was significantly reversed by fidarestat. The initial deficit and treatment-related improvement were especially evident for responses driven by high-frequency repetitive stimulation. Of the 11 parameters of bladder activity assessed, four measures-bladder capacity, micturition volume, micturition frequency, and bladder weight-were significantly different in the control and STZ-treated groups. These deficits were not affected by fidarestat. At Day 50, the induced deficits in bladder function were highly correlated with caudal NCV (r values ranging from 0.70 to 0.96; P values ranging from .02 to <.0001). These results suggested that fidarestat improved the slowing of somatic nerve NCV in hyperglycemic rats, but it was not effective in reversing associated bladder dysfunction, in spite of the highly significant correlation between these two diabetes-induced deficits. Possible explanations for this dissociation are discussed.
Nerve Conduction Through Dendrites via Proton Hopping.
Kier, Lemont B
2017-01-01
In our previous studies of nerve conduction conducted by proton hopping, we have considered the axon, soma, synapse and the nodes of Ranvier. The role of proton hopping described the passage of information through each of these units of a typical nerve system. The synapse projects information from the axon to the dendrite and their associated spines. We have invoked the passage of protons via a hopping mechanism to illustrate the continuum of the impulse through the system, via the soma following the dendrites. This is proposed to be a continuum invoked by the proton hopping method. With the proposal of the activity through the dendrites, via proton hopping, a complete model of the nerve function is invoked. At each step to the way, a water pathway is present and is invoked in the proposed model as the carrier of the message via proton hopping. The importance of the dendrites is evident by the presence of a vast number of spines, each possessing the possibility to carry unique messages through the nervous system. With this model of the role of dendrites, functioning with the presence of proton hopping, a complete model of the nerve system is presented. The validity of this model will be available for further studies and models to assess it's validity. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Phrenic Nerve Reconstruction and Bilateral Diaphragm Plication After Lobectomy.
Shinohara, Shuichi; Yamada, Tetsu; Ueda, Mitsuhiro; Ishinagi, Hiroyoshi; Matsuoka, Takahisa; Nagai, Shinjiro; Matsuoka, Katsunari; Miyamoto, Yoshihiro
2017-07-01
A 49-year-old man with left phrenic nerve paralysis caused by mediastinal tumor resection 28 years earlier was found to have a nodule in the right upper lobe. The right phrenic nerve was severed during right upper lobectomy but was reconstructed along with bilateral plication of the diaphragm. The patient was weaned from the ventilator during the daytime on postoperative day 13 and was discharged home on postoperative day 48. Three months postoperatively, chest fluoroscopic imaging showed recovery of movement of the right diaphragm. Nerve conduction studies showed improvement of function of the reconstructed right phrenic nerve. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Avoiding nerve stimulation in irreversible electroporation: a numerical modeling study
NASA Astrophysics Data System (ADS)
Mercadal, Borja; Arena, Christopher B.; Davalos, Rafael V.; Ivorra, Antoni
2017-10-01
Electroporation based treatments consist in applying one or multiple high voltage pulses to the tissues to be treated. As an undesired side effect, these pulses cause electrical stimulation of excitable tissues such as nerves and muscles. This increases the complexity of the treatments and may pose a risk to the patient. To minimize electrical stimulation during electroporation based treatments, it has been proposed to replace the commonly used monopolar pulses by bursts of short bipolar pulses. In the present study, we have numerically analyzed the rationale for such approach. We have compared different pulsing protocols in terms of their electroporation efficacy and their capability of triggering action potentials in nerves. For that, we have developed a modeling framework that combines numerical models of nerve fibers and experimental data on irreversible electroporation. Our results indicate that, by replacing the conventional relatively long monopolar pulses by bursts of short bipolar pulses, it is possible to ablate a large tissue region without triggering action potentials in a nearby nerve. Our models indicate that this is possible because, as the pulse length of these bipolar pulses is reduced, the stimulation thresholds raise faster than the irreversible electroporation thresholds. We propose that this different dependence on the pulse length is due to the fact that transmembrane charging for nerve fibers is much slower than that of cells treated by electroporation because of their geometrical differences.
Y1R control of sciatic nerve blood flow in the Wistar Kyoto rat.
Twynstra, Jasna; Medeiros, Philip J; Lacefield, James C; Jackson, Dwayne N; Shoemaker, J Kevin
2012-09-01
We hypothesized that neuropeptide Y (NPY) exerts vasoconstrictor properties in sciatic nerve blood supply by a Y1 receptor (Y1R) mechanism. Using Doppler ultrasound (40MHz), we measured blood flow velocity through a sciatic nerve supply artery during infusions of NPY and/or Y1R blockade with BIBP3226 in Wistar Kyoto rats before, and following, ganglionic blockade with Hexamethonium (Hex). Following Hex infusion, mean arterial pressure (baseline: 83±18, Hex: 57±3 mm Hg) was reduced. After 30 min, the index of conductance at the sciatic nerve (velocity/MAP expressed as % baseline) started to increase from 103±35 to 127±39% baseline in the following 30 min (p<0.05). Infusion of NPY (Y1 agonist) minimized this dilatory response (Hex baseline: 99±15, NPY: 104±11% baseline; NS). This NPY-induced attenuation was, in turn, minimized by BIBP3226 (Hex baseline: 73±12, NPY+BIBP3226: 89±14% baseline). Neither NPY nor BIBP3226 infusions without Hex affected the sciatic nerve arterial conductance. We conclude that the late dilation following Hex which is reversed by Y1R activation suggests some level of sympathetic control over sciatic nerve blood flow. Copyright © 2012 Elsevier Inc. All rights reserved.
Kim, Jin Hwan; Choi, Kyu Young; Lee, Kyu Ho; Lee, Dong Jin; Park, Bum Jung; Rho, Young-Soo
2014-01-01
To evaluate the motor input from the spinal accessory nerve (SAN) and the branches of the cervical plexus in an intraoperative motor nerve conduction study measuring motor action potentials by direct stimulation of the exposed nerve during neck dissection. The entire length of the SAN and the contributions from the upper cervical plexus were preserved. Compound muscle action potentials were measured for each part of the trapezius muscle on stimulation of the SAN, C2, C3, and C4 nerves. With stimulation of the spinal nerve, evoked responses were obtained from all 24 patients in the descending, transverse, and ascending trapezius muscle. C2 contributions were noted in 2 out of 24 patients; however, no patient revealed responses in all three parts of the muscle. C3 contributions were seen in 11 out of 24 patients, supplying all three parts of the muscle in 8 patients, and C4 contributions were noted in 20 out of 24 patients, supplying all three parts of the muscle in 16 of them. The SAN provided the most consistent motor input to the trapezius muscle. The C2, C3, and C4 nerves also provided motor input to the trapezius muscle; however, they were either inconsistently present or, when present, irregularly innervated the three parts of the trapezius muscle.
Fuchs, Peter; Zörer, Michael; Reipert, Siegfried; Rezniczek, Günther A.; Propst, Friedrich; Walko, Gernot; Fischer, Irmgard; Bauer, Jan; Leschnik, Michael W.; Lüscher, Bernhard; Thalhammer, Johann G.; Lassmann, Hans; Wiche, Gerhard
2009-01-01
Cytolinker proteins stabilize cells mechanically, regulate cytoskeleton dynamics, and provide scaffolds for signaling molecules. For plectin, the prototype of these proteins, an unusual diversity of isoforms has been reported, which show distinct expression patterns, subcellular localizations, and functions. Plectin has been shown to have important functions in skin and muscle, but little is known about its role in neural cells. To address this issue, we generated two knock-out mouse lines, one which was selectively lacking plectin 1c (P1c), the major isoform expressed in neural cells, and another in which plectin was conditionally deleted in neuronal precursor cells. Using isoform-specific antibodies, we found P1c to be expressed late in development and to associate with postsynaptic dendrites of central nervous system neurons, motorneurons of spinal cord, sciatic nerve axons, and Schwann cells. Motor nerve conduction velocity was found significantly reduced in sciatic nerve from P1c-deficient as well as from conditional knock-out mice. This defect was traceable to an increased number of motor nerve fibers with small cross-sectional areas; the thicknesses of axons and of myelin sheaths were unaffected. This is the first report demonstrating an important role of plectin in a major nerve function. PMID:19625254
Electrodiagnosis and nerve conduction studies.
Posuniak, E A
1984-08-01
The use of electrodiagnostic techniques in evaluation of complaints in the lower extremities provides an objective method of assessment. A basic understanding of principles of neurophysiology, EMG and NCV methodology, and neuropathology of peripheral nerves greatly enhances physical diagnosis and improves the state of the art in treatment of the lower extremity, especially foot and ankle injuries. Familiarity with the method of reporting electrodiagnostic studies and appreciation of the electromyographer's interpretation of the EMG/NCV studies also reflects an enhanced fund of knowledge, skills, and attitudes as pertains to one's level of professional expertise. Information regarding the etiology of positive sharp waves, fibrillation potentials, fasciculation, and normal motor action potentials and conduction studies serves as a sound basis for the appreciation of the categories of nerve injury. Competence in understanding the degree of axonal or myelin function or dysfunction in a nerve improve one's effectiveness not only in medical/surgical treatment but in prognostication of recovery of function. A review of the entrapment syndromes in the lower extremity with emphasis on tarsal tunnel syndrome summarizes the most common nerve entrapments germane to the practice of podiatry. With regard to tarsal tunnel syndrome, the earliest electrodiagnostic study to suggest compression was reported to be the EMG of the foot and leg muscles, even before prolonged nerve latency was noted.
Kon, Tomoya; Suzuki, Chieko; Hotta, Ryotaro; Funamizu, Yukihisa; Haga, Rie; Ueno, Tatsuya; Nishijima, Haruo; Arai, Akira; Nunomura, Jinichi; Nukada, Hitoshi; Tomiyama, Masahiko; Baba, Masayuki
2017-09-01
The clinical utility of nerve conduction study (NCS) for the distal medial branch of the superficial radial nerve (SRN) has not yet been clarified. Therefore, we investigated the clinical utility of NCS in patients with suspected SRN injury and compared the results with those in healthy control subjects. Bilateral NCS of the medial branch of the SRN was performed in two patients with suspected injury of the medial branch of the SRN, and in 20 healthy control subjects. A surface recording electrode was placed at the medial side of the metacarpophalangeal joint of the thumb. The SRN was then stimulated at a location 12 cm proximal from the recording electrode. The mean sensory nerve action potential in the two patients was significantly lower than that of the controls (6.75 ± 0.92 vs. 23.8 ± 8.2 μV, P < 0.05). The side-to-side differences in sensory nerve action potential in the two patients were significantly higher than in the controls (55 ± 7.1 vs. 11 ± 7.8%, P < 0.05). NCS may be useful for diagnosing injury of the medial branch of the SRN.
Evolution of rapid nerve conduction.
Castelfranco, Ann M; Hartline, Daniel K
2016-06-15
Rapid conduction of nerve impulses is a priority for organisms needing to react quickly to events in their environment. While myelin may be viewed as the crowning innovation bringing about rapid conduction, the evolution of rapid communication mechanisms, including those refined and enhanced in the evolution of myelin, has much deeper roots. In this review, a sequence is traced starting with diffusional communication, followed by transport-facilitated communication, the rise of electrical signaling modalities, the invention of voltage-gated channels and "all-or-none" impulses, the emergence of elongate nerve axons specialized for communication and their fine-tuning to enhance impulse conduction speeds. Finally within the evolution of myelin itself, several innovations have arisen and have been interactively refined for speed enhancement, including the addition and sealing of layers, their limitation by space availability, and the optimization of key parameters: channel density, lengths of exposed nodes and lengths of internodes. We finish by suggesting several design principles that appear to govern the evolution of rapid conduction. This article is part of a Special Issue entitled SI: Myelin Evolution. Copyright © 2016. Published by Elsevier B.V.
Hashemian, Hesam; Jabbarvand, Mahmoud; Khodaparast, Mehdi; Ameli, Kambiz
2014-12-01
To evaluate the outcome of accelerated and conventional corneal cross-linking (CXL) procedures regarding their effect on morphological and optical properties of the cornea. One hundred fifty-three eyes of 153 patients were evaluated before and during a 15-month follow-up period after CXL (76 eyes in the conventional group and 77 eyes in the accelerated group). Measured variables include corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), refraction, maximum keratometry, endothelial cell density, anterior and posterior stromal keratocyte density, and subbasal nerve density. All variables were compared between the two study groups. Cylindrical and spherical components of refraction improved significantly during 15 months of follow-up. No difference was observed between the two study groups. UDVA and CDVA improved in the same manner, with no intergroup differences. Endothelial cell density did not change significantly during the follow-up period in either group. K-max increased slightly in the first month of the follow-up, but started to decrease at postoperative visits without any significant difference in the two groups. Anterior stromal keratocyte density and subbasal nerve density decreased significantly in both groups 1 month postoperatively. Both variables had a more significant decrease in the conventional group at all visits before the 1-year visit. At the final 15-month visit, there were no significant differences in any value between the two groups. Accelerated and conventional CXL seem to have a comparable and acceptable effect on keratoconus in the short-term follow-up period. Copyright 2014, SLACK Incorporated.
Gao, Kai-ming; Hu, Jing-jing; Lao, Jie; Zhao, Xin
2018-01-01
Despite recent great progress in diagnosis and microsurgical repair, the prognosis in total brachial plexus-avulsion injury remains unfavorable. Insufficient number of donors and unreasonable use of donor nerves might be key factors. To identify an optimal treatment strategy for this condition, we conducted a retrospective review. Seventy-three patients with total brachial plexus avulsion injury were followed up for an average of 7.3 years. Our analysis demonstrated no significant difference in elbow-flexion recovery between phrenic nerve-transfer (25 cases), phrenic nerve-graft (19 cases), intercostal nerve (17 cases), or contralateral C7-transfer (12 cases) groups. Restoration of shoulder function was attempted through anterior accessory nerve (27 cases), posterior accessory nerve (10 cases), intercostal nerve (5 cases), or accessory + intercostal nerve transfer (31 cases). Accessory nerve + intercostal nerve transfer was the most effective method. A significantly greater amount of elbow extension was observed in patients with intercostal nerve transfer (25 cases) than in those with contralateral C7 transfer (10 cases). Recovery of median nerve function was noticeably better for those who received entire contralateral C7 transfer (33 cases) than for those who received partial contralateral C7 transfer (40 cases). Wrist and finger extension were reconstructed by intercostal nerve transfer (31 cases). Overall, the recommended surgical treatment for total brachial plexus-avulsion injury is phrenic nerve transfer for elbow flexion, accessory nerve + intercostal nerve transfer for shoulder function, intercostal nerves transfer for elbow extension, entire contralateral C7 transfer for median nerve function, and intercostal nerve transfer for finger extension. The trial was registered at ClinicalTrials.gov (identifier: NCT03166033). PMID:29623932
Gao, Kai-Ming; Hu, Jing-Jing; Lao, Jie; Zhao, Xin
2018-03-01
Despite recent great progress in diagnosis and microsurgical repair, the prognosis in total brachial plexus-avulsion injury remains unfavorable. Insufficient number of donors and unreasonable use of donor nerves might be key factors. To identify an optimal treatment strategy for this condition, we conducted a retrospective review. Seventy-three patients with total brachial plexus avulsion injury were followed up for an average of 7.3 years. Our analysis demonstrated no significant difference in elbow-flexion recovery between phrenic nerve-transfer (25 cases), phrenic nerve-graft (19 cases), intercostal nerve (17 cases), or contralateral C 7 -transfer (12 cases) groups. Restoration of shoulder function was attempted through anterior accessory nerve (27 cases), posterior accessory nerve (10 cases), intercostal nerve (5 cases), or accessory + intercostal nerve transfer (31 cases). Accessory nerve + intercostal nerve transfer was the most effective method. A significantly greater amount of elbow extension was observed in patients with intercostal nerve transfer (25 cases) than in those with contralateral C 7 transfer (10 cases). Recovery of median nerve function was noticeably better for those who received entire contralateral C 7 transfer (33 cases) than for those who received partial contralateral C 7 transfer (40 cases). Wrist and finger extension were reconstructed by intercostal nerve transfer (31 cases). Overall, the recommended surgical treatment for total brachial plexus-avulsion injury is phrenic nerve transfer for elbow flexion, accessory nerve + intercostal nerve transfer for shoulder function, intercostal nerves transfer for elbow extension, entire contralateral C 7 transfer for median nerve function, and intercostal nerve transfer for finger extension. The trial was registered at ClinicalTrials.gov (identifier: NCT03166033).
Myrcha, P; Ciostek, P; Szopiński, P; Noszczyk, W
2001-01-01
The aim of the study was an assessment of the incidence of injury to cranial and peripheral nerves as complication of patency restoration of the internal carotid artery, and analysis of the effect of peripheral nerve injury on the results of carotid patency restoration. From Oct 1987 to Sept 1999 543 procedures were carried out for restoration of patency of the internal carotid artery. After the operation hypoglossus nerve injury was found in 7 cases (1.4%), vagus injury in 9 (1.8%). Signs of exclusively recurrent laryngeal nerve damage were found in 6 cases (1.2%). Glossopharyngeus nerve was damaged in 2 cases (0.4%), transient phrenic nerve palsy as a result of conduction anaesthesia was noted in 2 cases (0.4%). Damage to the transverse cervical nerve was found in 96 cases (60%). In 2 patients (1.2%) lower position of mouth angle was due to section of the mandibular ramus of the facial nerve. In another 2 cases skin sensation disturbances were a consequence of lesion of the auricularis magnus nerve and always they coexisted with signs of transverse cervical nerve damage. damage to the cranial nerves during operation for carotid patency restoration are frequent but mostly they are not connected with any health risks and often they regress spontaneously.
Promising Technique for Facial Nerve Reconstruction in Extended Parotidectomy
Villarreal, Ithzel Maria; Rodríguez-Valiente, Antonio; Castelló, Jose Ramon; Górriz, Carmen; Montero, Oscar Alvarez; García-Berrocal, Jose Ramon
2015-01-01
Introduction: Malignant tumors of the parotid gland account scarcely for 5% of all head and neck tumors. Most of these neoplasms have a high tendency for recurrence, local infiltration, perineural extension, and metastasis. Although uncommon, these malignant tumors require complex surgical treatment sometimes involving a total parotidectomy including a complete facial nerve resection. Severe functional and aesthetic facial defects are the result of a complete sacrifice or injury to isolated branches becoming an uncomfortable distress for patients and a major challenge for reconstructive surgeons. Case Report: A case of a 54-year-old, systemically healthy male patient with a 4 month complaint of pain and swelling on the right side of the face is presented. The patient reported a rapid increase in the size of the lesion over the past 2 months. Imaging tests and histopathological analysis reported an adenoid cystic carcinoma. A complete parotidectomy was carried out with an intraoperative notice of facial nerve infiltration requiring a second intervention for nerve and defect reconstruction. A free ALT flap with vascularized nerve grafts was the surgical choice. A 6 month follow-up showed partial facial movement recovery and the facial defect mended. Conclusion: It is of critical importance to restore function to patients with facial nerve injury. Vascularized nerve grafts, in many clinical and experimental studies, have shown to result in better nerve regeneration than conventional non-vascularized nerve grafts. Nevertheless, there are factors that may affect the degree, speed and regeneration rate regarding the free fasciocutaneous flap. In complex head and neck defects following a total parotidectomy, the extended free fasciocutaneous ALT (anterior-lateral thigh) flap with a vascularized nerve graft is ideally suited for the reconstruction of the injured site. Donor–site morbidity is low and additional surgical time is minimal compared with the time of a single ALT flap transfer. PMID:26788494
Su, Diya; Li, Dezhi; Wang, Shiwei; Qiao, Hui; Li, Ping; Wang, Binbin; Wan, Hong; Schumacher, Michael; Liu, Song
2018-06-06
Closed temporal bone fractures due to cranial trauma often result in facial nerve injury, frequently inducing incomplete facial paralysis. Conventional hypoglossal-facial nerve end-to-end neurorrhaphy may not be suitable for these injuries because sacrifice of the lesioned facial nerve for neurorrhaphy destroys the remnant axons and/or potential spontaneous innervation. we modified the classical method by hypoglossal-facial nerve "side"-to-side neurorrhaphy using an interpositional predegenerated nerve graft to treat these injuries. Five patients who experienced facial paralysis resulting from closed temporal bone fractures due to cranial trauma were treated with the "side"-to-side neurorrhaphy. An additional 4 patients did not receive the neurorrhaphy and served as controls. Before treatment, all patients had suffered House-Brackmann (H-B) grade V or VI facial paralysis for a mean of 5 months. During the 12-30 months of follow-up period, no further detectable deficits were observed, but an improvement in facial nerve function was evidenced over time in the 5 neurorrhaphy-treated patients. At the end of follow-up, the improved facial function reached H-B grade II in 3, grade III in 1 and grade IV in 1 of the 5 patients, consistent with the electrophysiological examinations. In the control group, two patients showed slightly spontaneous innervation with facial function improved from H-B grade VI to V, and the other patients remained unchanged at H-B grade V or VI. We concluded that the hypoglossal-facial nerve "side"-to-side neurorrhaphy can preserve the injured facial nerve and is suitable for treating significant incomplete facial paralysis resulting from closed temporal bone fractures, providing an evident beneficial effect. Moreover, this treatment may be performed earlier after the onset of facial paralysis in order to reduce the unfavorable changes to the injured facial nerve and atrophy of its target muscles due to long-term denervation and allow axonal regrowth in a rich supportive environment.
Electric stimulation and decimeter wave therapy improve the recovery of injured sciatic nerves
Zhao, Feng; He, Wei; Zhang, Yingze; Tian, Dehu; Zhao, Hongfang; Yu, Kunlun; Bai, Jiangbo
2013-01-01
Drug treatment, electric stimulation and decimeter wave therapy have been shown to promote the repair and regeneration of the peripheral nerves at the injured site. This study prepared a Mackinnon's model of rat sciatic nerve compression. Electric stimulation was given immediately after neurolysis, and decimeter wave radiation was performed at 1 and 12 weeks post-operation. Histological observation revealed that intraoperative electric stimulation and decimeter wave therapy could improve the local blood circulation of repaired sites, alleviate hypoxia of compressed nerves, and lessen adhesion of compressed nerves, thereby decreasing the formation of new entrapments and enhancing compressed nerve regeneration through an improved microenvironment for regeneration. Immunohistochemical staining results revealed that intraoperative electric stimulation and decimeter wave could promote the expression of S-100 protein. Motor nerve conduction velocity and amplitude, the number and diameter of myelinated nerve fibers, and sciatic functional index were significantly increased in the treated rats. These results verified that intraoperative electric stimulation and decimeter wave therapy contributed to the regeneration and the recovery of the functions in the compressed nerves. PMID:25206506
Local Variability of Parameters for Characterization of the Corneal Subbasal Nerve Plexus.
Winter, Karsten; Scheibe, Patrick; Köhler, Bernd; Allgeier, Stephan; Guthoff, Rudolf F; Stachs, Oliver
2016-01-01
The corneal subbasal nerve plexus (SNP) offers high potential for early diagnosis of diabetic peripheral neuropathy. Changes in subbasal nerve fibers can be assessed in vivo by confocal laser scanning microscopy (CLSM) and quantified using specific parameters. While current study results agree regarding parameter tendency, there are considerable differences in terms of absolute values. The present study set out to identify factors that might account for this high parameter variability. In three healthy subjects, we used a novel method of software-based large-scale reconstruction that provided SNP images of the central cornea, decomposed the image areas into all possible image sections corresponding to the size of a single conventional CLSM image (0.16 mm2), and calculated a set of parameters for each image section. In order to carry out a large number of virtual examinations within the reconstructed image areas, an extensive simulation procedure (10,000 runs per image) was implemented. The three analyzed images ranged in size from 3.75 mm2 to 4.27 mm2. The spatial configuration of the subbasal nerve fiber networks varied greatly across the cornea and thus caused heavily location-dependent results as well as wide value ranges for the parameters assessed. Distributions of SNP parameter values varied greatly between the three images and showed significant differences between all images for every parameter calculated (p < 0.001 in each case). The relatively small size of the conventionally evaluated SNP area is a contributory factor in high SNP parameter variability. Averaging of parameter values based on multiple CLSM frames does not necessarily result in good approximations of the respective reference values of the whole image area. This illustrates the potential for examiner bias when selecting SNP images in the central corneal area.
A new rule for femoral nerve blocks.
Schulz-Stübner, Sebastian; Henszel, Angela; Hata, J Steven
2005-01-01
Acupuncture points are described by use of a proportional system that is based on the width of the thumb at the level of the distal interphalangeal joint, defined as 1 CUN. Our study tested first the correlation between the CUN and weight and height in 500 Americans and second the hypothesis that the CUN system is superior to the conventional landmarks to localize the femoral nerve 1 or 2 cm lateral to the artery in a prospective, double-blinded, randomized study. Sixty-two patients were randomized to receive a femoral nerve block by a needle entry point either 1 CUN lateral, 1 cm lateral, or 2 cm lateral to the femoral artery at the level of the inguinal crease. The time from needle entry to injection of local anesthetic was measured by an investigator blind to the technique, who also counted the frequency of needle repositioning, graded the ease of the block and its success, and registered complications. Good correlation occurred between weight and CUN (r = 0.79) and height and CUN (r = 0.83), which indicates that the CUN of a normal person (predefined as 175 cm tall and 70 kg weight) is 18.7 +/- 1 mm. In the CUN group, the femoral block was achieved significantly faster (P < .01) with fewer attempts (P < .003). The success rate was the same and complications did not differ significantly between the groups. A needle insertion point 1 CUN lateral to the midpoint of the palpated femoral artery at the level of the inguinal crease makes femoral nerve blocks faster and easier compared with conventional landmark 1 cm to 2 cm lateral to the artery.
Hegmann, Kurt T; Thiese, Matthew Steven; Kapellusch, Jay; Merryweather, Andrew S; Bao, Stephen; Silverstein, Barbara; Wood, Eric M; Kendall, Richard; Wertsch, Jacqueline; Foster, James; Garg, Arun; Drury, David L
2016-01-01
The aim of the study was to ascertain if cardiovascular (CVD) risk factors are carpal tunnel syndrome (CTS) risk factors. Analysis of pooled baseline data from two large prospective cohort studies (n = 1824) assessed the relationships between a modified Framingham Heart Study CVD risk score both CTS and abnormal nerve conduction study prevalence. Quantified job exposures, personal and psychosocial confounders were statistically controlled. Odds ratio and 95% confidence intervals were calculated for individual risk scores. There was a strong relationship between CVD risk score and both CTS and abnormal nerve conduction study after adjustment for confounders, with odds ratios as high as 4.16 and 7.35, respectively. Dose responses were also observed. In this workplace population, there is a strong association between CVD risk scores and both CTS and abnormal nerve conduction study that persisted after controlling for confounders. These data suggest a potentially modifiable disease mechanism.
Effect of nerve monitoring on complications of thyroid surgery
Demiryas, Suleyman; Donmez, Turgut; Cekic, Erdinc
2018-01-01
OBJECTIVE: The most frequent and critical complications of thyroid surgery are recurrent laryngeal nerve palsy and hypocalcemia. In first years of the 21st century, intraoperative neuromonitoring (IONM) was introduced as a new technique to avoid the recurrent laryngeal nerve (RLN) injury. However, the role and the benefits of IONM are still controversial. In this study, we aimed to compare the postoperative complication rates during thyroid surgery with IONM usage (Group 1) and conventional direct visual technique without IONM usage (Group 2). METHODS: We conducted retrospective review of all patients undergoing thyroid surgery in Lütfiye Nuri Burat State Hospital General Surgery Department between 2014 and 2016 years. Patients have been classified in to two groups: Group 1 and 2. RESULTS: Overall, 191 patients were included in the study; Group 1 comprised 79 patients and Group 2 comprised 112 patients. Unilateral RLN paralysis was observed in 7 patients in Group 1 (8.9%) and 15 patients in Group 2 (13.4%) without any significant difference between the groups (p=0.368). Hypocalcemia was encountered in 5 patients (6.3%) in Group 1 and 18 patients (16.1%) in Group 2; this difference was statistically significant (p=0.045). Other complications (such as hematoma and suture reaction) were not significantly different. Operation time was found to be significantly shorter in Group 1 (Mean time, 93.08 min) than in Group 2 (116.54 min) (p=0.03). CONCLUSION: Proven effect of IONM on RLN paralysis is still controversial. However, easy identification of RLN, which gives more confidence to surgeon, and shorter operation time may be factors to lower hypocalcemia rates. PMID:29607426
Guven, Mustafa; Kahraman, Ibrahim; Koc, Filiz; Bozdemir, Hacer; Sarica, Yakup; Gunay, Ismail
2011-01-01
Oxcarbazepine is an antiepileptic drug widely used for the treatment of neuropathic pain. In the present study, the effects of oxcarbazepine and lamotrigine on conduction properties in the rat sciatic nerves were examined. The experiments were conducted with in vitro sucrose-gap technique on the isolated wistar rat sciatic nerves. The compound action potentials were obtained by tonic (single) and phasic (10, 40, and 100 Hz) stimulation. Oxcarbazepine produced a significant concentration- and frequency-dependent reduction in the compound action potential amplitude. When the two drugs were applied at concentrations that produced equal levels of tonic (i.e., non-frequency-dependent) conduction block, oxcarbazepine produced the greatest phasic (i.e., frequency-dependent) conduction block, followed by lamotrigine. Oxcarbazepine and lamotrigine reduced the 4-aminopyridine-induced amplitude of delayed depolarization; however, oxcarbazepine had a significantly greater effect than lamotrigine. These results suggest that oxcarbazepine produces more potent frequency-dependent conduction block than lamotrigine, and suppresses the delayed depolarization which contributes to sensory signaling and may play a role in neuropathic pain. The findings provide insight into the mechanisms of action of oxcarbazepine and lamotrigine and may help in the development of novel therapies for neuropathic pain.
Xie, Jin; Jin, Bin; Li, Da-Wei; Shen, Bin; Gong, Ning; Zhang, Tian-Zhen; Dong, Pin
2015-01-01
Recurrent laryngeal nerve injury is a common severe complication in neck surgery, which can cause varying degrees of vocal fold paralysis and respiratory tract problems. In present study, the effects of laminin-binding brain derived neurotrophic factor (LBD-BDNF) on recurrent laryngeal nerve regeneration were explored and its possible mechanism was investigated. LBD-BDNF or NAT-BDNF (BDNF without LBD binding) treatment was performed in laryngeal nerve injured rabbits for sixteen weeks. The laryngeal nerve was removed, and histological examination as well as laryngeal electromyography was employed to evaluate its morphology and function of conduction. PC12 cells were cultured to investigate the mechanisms underlying the effects of LBD-BDNF. Neurite outgrowth, proliferation and migration were determined in nerve cells. The expression of miRNAs and protein of mTOR was quantified by real-time PCR and western blotting respectively. In vivo experiments, LBD-BDNF significantly improved the histological structure and function of recurrent laryngeal nerve compared with NAT-BDNF. LBD-BDNF also markedly promoted neurite outgrowth, proliferation and migration in PC12 cells in vitro experiments. The levels of miR-222 and p-mTOR were up-regulated by LBD-BDNF treatment in both in vivo and in vitro experiments. miR-222 inhibitor attenuated the expression of phosphorylated mTOR and miR-222 mimic enhanced its expression in PC12 cells. In addition, the improved nerve conduction by LBD-BDNF was canceled by miR-222 inhibitor, and the mTOR inhibitor reversed the effects of miR-222 inhibitor on LBD-BDNF treated cells. The present study revealed that LBD-BDNF promoted the recurrent laryngeal nerve regeneration in laryngeal nerve injured rabbits. The underlying mechanism was closely related to activation of p-mTOR by miR-222.
Xie, Jin; Jin, Bin; Li, Da-Wei; Shen, Bin; Gong, Ning; Zhang, Tian-Zhen; Dong, Pin
2015-01-01
Background and Aim: Recurrent laryngeal nerve injury is a common severe complication in neck surgery, which can cause varying degrees of vocal fold paralysis and respiratory tract problems. In present study, the effects of laminin-binding brain derived neurotrophic factor (LBD-BDNF) on recurrent laryngeal nerve regeneration were explored and its possible mechanism was investigated. Methods: LBD-BDNF or NAT-BDNF (BDNF without LBD binding) treatment was performed in laryngeal nerve injured rabbits for sixteen weeks. The laryngeal nerve was removed, and histological examination as well as laryngeal electromyography was employed to evaluate its morphology and function of conduction. PC12 cells were cultured to investigate the mechanisms underlying the effects of LBD-BDNF. Neurite outgrowth, proliferation and migration were determined in nerve cells. The expression of miRNAs and protein of mTOR was quantified by real-time PCR and western blotting respectively. Results: In vivo experiments, LBD-BDNF significantly improved the histological structure and function of recurrent laryngeal nerve compared with NAT-BDNF. LBD-BDNF also markedly promoted neurite outgrowth, proliferation and migration in PC12 cells in vitro experiments. The levels of miR-222 and p-mTOR were up-regulated by LBD-BDNF treatment in both in vivo and in vitro experiments. miR-222 inhibitor attenuated the expression of phosphorylated mTOR and miR-222 mimic enhanced its expression in PC12 cells. In addition, the improved nerve conduction by LBD-BDNF was canceled by miR-222 inhibitor, and the mTOR inhibitor reversed the effects of miR-222 inhibitor on LBD-BDNF treated cells. Conclusions: The present study revealed that LBD-BDNF promoted the recurrent laryngeal nerve regeneration in laryngeal nerve injured rabbits. The underlying mechanism was closely related to activation of p-mTOR by miR-222. PMID:26279751
Jang, Jae Hong; Cho, Charles S; Yang, Kyung-Sook; Seok, Hung Youl; Kim, Byung-Jo
2014-09-01
Focal nerve enlargement is a characteristic finding in chronic inflammatory demyelinating polyneuropathy (CIDP). We performed this study to assess the distribution of nerve enlargement through ultrasonographic examination of peripheral nerves and to correlate the ultrasonographic findings with clinical features. To compare the ultrasonographic features of 10 subjects with CIDP with those of 18 healthy controls, we bilaterally measured the cross-sectional areas (CSA) of the vagus, brachial plexus, musculocutaneous, median, ulnar, radial, sciatic, tibial, common peroneal, and sural nerves. We also analyzed correlations between CSAs and various clinical and electrophysiological features. Mean CSAs were significantly larger in CIDP patients than controls, especially at proximal and non-entrapment sites. CSAs were significantly correlated with muscle strength at initial presentation, but not at the time of ultrasonography. The CSAs of the median and ulnar nerves at the mid-forearm, tibial nerve at 7 cm proximal to the medial malleolus, and sural nerve correlated with the nerve conduction velocity of the corresponding region. Ultrasonography revealed widely distributed nerve enlargement, especially in proximal regions and non-entrapment sites, in patients with CIDP compared with healthy controls. Nerve enlargement correlated well with the electrophysiologic function of the nerve, but not current clinical status. Pattern analysis of nerve enlargement using ultrasonography is a supportive tool in the diagnosis of CIDP. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
4.7-T diffusion tensor imaging of acute traumatic peripheral nerve injury
Boyer, Richard B.; Kelm, Nathaniel D.; Riley, D. Colton; Sexton, Kevin W.; Pollins, Alonda C.; Shack, R. Bruce; Dortch, Richard D.; Nanney, Lillian B.; Does, Mark D.; Thayer, Wesley P.
2015-01-01
Diagnosis and management of peripheral nerve injury is complicated by the inability to assess microstructural features of injured nerve fibers via clinical examination and electrophysiology. Diffusion tensor imaging (DTI) has been shown to accurately detect nerve injury and regeneration in crush models of peripheral nerve injury, but no prior studies have been conducted on nerve transection, a surgical emergency that can lead to permanent weakness or paralysis. Acute sciatic nerve injuries were performed microsurgically to produce multiple grades of nerve transection in rats that were harvested 1 hour after surgery. High-resolution diffusion tensor images from ex vivo sciatic nerves were obtained using diffusion-weighted spin-echo acquisitions at 4.7 T. Fractional anisotropy was significantly reduced at the injury sites of transected rats compared with sham rats. Additionally, minor eigenvalues and radial diffusivity were profoundly elevated at all injury sites and were negatively correlated to the degree of injury. Diffusion tensor tractography showed discontinuities at all injury sites and significantly reduced continuous tract counts. These findings demonstrate that high-resolution DTI is a promising tool for acute diagnosis and grading of traumatic peripheral nerve injuries. PMID:26323827
Use of Vein Conduit and Isolated Nerve Graft in Peripheral Nerve Repair: A Comparative Study
Ahmad, Imran; Akhtar, Md. Sohaib
2014-01-01
Aims and Objectives. The aim of this study was to evaluate the effectiveness of vein conduit in nerve repair compared with isolated nerve graft. Materials and Methods. This retrospective study was conducted at author's centre and included a total of 40 patients. All the patients had nerve defect of more than 3 cm and underwent nerve repair using nerve graft from sural nerve. In 20 cases, vein conduit (study group) was used whereas no conduit was used in other 20 cases. Patients were followed up for 2 years at the intervals of 3 months. Results. Patients had varying degree of recovery. Sensations reached to all the digits at 1 year in study groups compared to 18 months in control group. At the end of second year, 84% patients of the study group achieved 2-point discrimination of <10 mm compared to 60% only in control group. In terms of motor recovery, 82% patients achieved satisfactory hand function in study group compared to 56% in control group (P < .05). Conclusions. It was concluded that the use of vein conduit in peripheral nerve repair is more effective method than isolated nerve graft providing good sensory and motor recovery. PMID:25405029
Montserrat-Bosch, Marta; Figueiredo, Rui; Nogueira-Magalhães, Pedro; Arnabat-Dominguez, Josep; Valmaseda-Castellón, Eduard; Gay-Escoda, Cosme
2014-07-01
To compare the efficacy and complication rates of two different techniques for inferior alveolar nerve blocks (IANB). A randomized, triple-blind clinical trial comprising 109 patients who required lower third molar removal was performed. In the control group, all patients received an IANB using the conventional Halsted technique, whereas in the experimental group, a modified technique using a more inferior injection point was performed. A total of 100 patients were randomized. The modified technique group showed a significantly higher onset time in the lower lip and chin area, and was frequently associated to a lingual electric discharge sensation. Three failures were recorded, 2 of them in the experimental group. No relevant local or systemic complications were registered. Both IANB techniques used in this trial are suitable for lower third molar removal. However, performing an inferior alveolar nerve block in a more inferior position (modified technique) extends the onset time, does not seem to reduce the risk of intravascular injections and might increase the risk of lingual nerve injuries.
Claffey, Elizabeth; Reader, Al; Nusstein, John; Beck, Mike; Weaver, Joel
2004-08-01
The purpose of this prospective, randomized, double-blind study was to compare the anesthetic efficacy of 4% articaine with 1:100,000 epinephrine to 2% lidocaine with 1:100,000 epinephrine for inferior alveolar nerve blocks in patients experiencing irreversible pulpitis in mandibular posterior teeth. Seventy-two emergency patients diagnosed with irreversible pulpitis of a mandibular posterior tooth randomly received, in a double-blind manner, 2.2 ml of 4% articaine with 1:100,000 epinephrine or 2.2 ml of 2% lidocaine with 1:100,000 epinephrine using a conventional inferior alveolar nerve block. Endodontic access was begun 15 min after solution deposition, and all patients were required to have profound lip numbness. Success was defined as none or mild pain (Visual Analogue Scale recordings) on endodontic access or initial instrumentation. The success rate for the inferior alveolar nerve block using articaine was 24% and for the lidocaine solution success was 23%. There was no significant difference (p = 0.89) between the articaine and lidocaine solutions. Neither solution resulted in an acceptable rate of anesthetic success in patients with irreversible pulpitis.
Evaluative procedures to detect, characterize, and assess the severity of diabetic neuropathy.
Dyck, P J
1991-01-01
Minimal criteria for diabetic neuropathy need to be defined and universally applied. Standardized evaluative procedures need to be agreed and normal ranges determined from healthy volunteers. Types and stages of neuropathy should be established and assessments performed on representative populations of both Type 1 and Type 2 diabetic patients. Potential minimal criteria include absent ankle reflexes and vibratory sensation, and abnormalities of nerve conduction. However, the preferred criterion is the identification of more than two statistically defined abnormalities among symptoms and deficits, nerve conduction, quantitative sensory examination or quantitative autonomic examination. Various evaluative procedures are available. Symptoms should be assessed and scores can be assigned to neurological deficits. However, assessments of nerve conduction provide the most specific, objective, sensitive, and repeatable procedures, although these may be the least meaningful. Many techniques are available for quantitative sensory examination, but are poorly standardized and normal values are not available. For quantitative autonomic examination, tests are available for the adequacy of cardiovascular and peripheral vascular reflexes and increasingly for other autonomic functions. In any assessment of nerve function the conditions should be optimized and standardized, and stimuli defined. Specific instructions should be given and normal ranges established in healthy volunteers.
Smith, Nicholas; Pereira, John; Grattan-Smith, Padraic
2014-10-01
To review the role of gadolinium-enhanced magnetic resonance imaging of the spine in the diagnosis of paediatric Guillain-Barre syndrome and compare it with nerve conduction studies and cerebrospinal fluid analysis. A retrospective review of investigations undertaken in children admitted to our institution with acute Guillain-Barre syndrome over a 10-year period was performed. Seven of eight children (88%) displayed post-gadolinium nerve root enhancement consistent with Guillain-Barre syndrome. This compared with supportive nerve conduction studies in 21/24 children (88%) and cerebrospinal fluid protein analysis consistent with the diagnosis in 16/20 children (80%). Nerve conduction studies are the recognised 'gold standard' technique for confirming a clinical diagnosis of Guillain-Barre syndrome. In this study, a high positive rate was demonstrated. While more experience is necessary, this study and the literature support gadolinium enhanced magnetic resonance imaging of the spine as a valuable, although not necessarily superior, investigation in the diagnosis of Guillain-Barre syndrome. It may be of particular benefit when specialist neurophysiology expertise is unavailable. © 2010 The Authors. Journal compilation © 2010 Paediatrics and Child Health Division (Royal Australasian College of Physicians).
Sensitive and Motor Neuroanastomosis After Facial Trauma.
Ribeiro-Junior, Paulo Domingos; Senko, Ricardo Alexandre Galdioli; Mendes, Gabriel Cury Batista; Peres, Fernando Gianzanti
2016-10-01
Facial nerve has great functional and aesthetic importance to the face, and damage to its structure can lead to major complications. This article reports a clinical case of neuroanastomosis of the facial nerve after facial trauma, describing surgical procedure and postoperative follow-up. A trauma patient with extensive injury cut in right mandibular body causing neurotmesis of the VIIth cranial nerve and mandibular angle fracture right side was treated. During surgical exploration, the nerve segments were identified and a neuroanastomosis was performed using nylon 10-0, after reduction and internal fixation of the mandibular fracture. Postoperatively, an 8-month follow-up showed good evolution and preservation of motor function of the muscles of facial mime, highlighting the success of the surgical treatment. Nerve damage because of facial trauma can be a surgical treatment challenge, but when properly conducted can functionally restore the damaged nerve.
Lozeron, Pierre; Trocello, Jean-Marc; Kubis, Nathalie
2013-09-01
Acquired neuropathies represent most of the neuropathies encountered in clinical practice. Hundreds of causes have been identified even though up to 41% of patients are still classified as idiopathic (Rajabally and Shah in J Neurol 258:1431-1436, 1). Routine evaluation relies on comprehensive medical history taking, clinical examination, nerve conduction studies and laboratory tests. Other investigations such as nerve biopsy or nerve or muscle imaging are performed in specific settings. This review focuses on recent advances in acquired neuropathies.
Current perspective of neuroprotection and glaucoma
Tian, Kailin; Shibata-Germanos, Shannon; Pahlitzsch, Milena; Cordeiro, M Francesca
2015-01-01
Glaucoma is the second leading cause of blindness worldwide and is most notably characterized by progressive optic nerve atrophy and advancing loss of retinal ganglion cells (RGCs). The main concomitant factor is the elevated intraocular pressure (IOP). Existing treatments are focused generally on lowering IOP. However, both RGC loss and optic nerve atrophy can independently occur with IOP at normal levels. In recent years, there has been substantial progress in the development of neuroprotective therapies for glaucoma in order to restore vital visual function. The present review intends to offer a brief insight into conventional glaucoma treatments and discuss exciting current developments of mostly preclinical data in novel neuroprotective strategies for glaucoma that include recent advances in noninvasive diagnostics going beyond IOP maintenance for an enhanced global view. Such strategies now target RGC loss and optic nerve damage, opening a critical therapeutic window for preventative monitoring and treatment. PMID:26635467
Less common upper limb mononeuropathies.
Williams, Faren H; Kumiga, Bryan
2013-05-01
This article will focus on the less commonly injured nerves of the upper extremity. These nerves may be involved when trauma results in fractures, dislocations, or swelling with resultant nerve compression. Tumors and ganglions can also compress nerves, causing pain and, over time, demyelination or axon degeneration with weakness. Other mechanisms for upper limb nerve injury include participation in high-level sports, that is, those that generate torque about the arm and shoulder, abnormal stresses about the joints and muscles, or muscle hypertrophy, which may result in nerve injury. The goals of this review are to discuss the clinical presentation and possible causes of upper extremity nerve entrapments and to formulate an electrodiagnostic plan for evaluation. Descriptions of the appropriate nerve conduction studies or needle electromyographic protocols are included for specific nerves. The purpose of the electrodiagnostic examination is to evaluate the degree of nerve injury, axon loss over time, and later, evidence for reinnervation to assist with prognostication. The latter has implications for management of the neuropathy, including the type of exercises and therapy that may be indicated to help maintain the stability and motion of the involved joint(s) and promote strengthening over time as the nerve regenerates. Copyright © 2013 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Meyer-Hamme, Gesa; Friedemann, Thomas; Greten, Henry Johannes; Plaetke, Rosemarie; Gerloff, Christian; Schroeder, Sven
2018-04-13
Diabetic peripheral neuropathy (DPN) is the most common complication of diabetes mellitus with significant clinical sequelae that can affect a patient's quality of life. Metabolic and microvascular factors are responsible for nerve damage, causing loss of nerve function, numbness, painful sensory symptoms, and muscle weakness. Therapy is limited to anti-convulsant or anti-depressant drugs for neuropathic pain and paresthesia. However, reduced sensation, balance and gait problems are insufficiently covered by this treatment. Previous data suggests that acupuncture, which has been in use in Traditional Chinese Medicine for many years, may potentially complement the treatment options for peripheral neuropathy. Nevertheless, more objective data on clinical outcome is necessary to generally recommend acupuncture to the public. We developed a study design for a prospective, randomized (RCT), placebo-controlled, partially double-blinded trial for investigating the effect of acupuncture on DPN as determined by nerve conduction studies (NCS) with the sural sensory nerve action potential amplitude as the primary outcome. The sural sensory nerve conduction velocity, tibial motor nerve action potential amplitude, tibial motor nerve conduction velocity, the neuropathy deficit score, neuropathy symptom score, and numeric rating scale questionnaires are defined as secondary outcomes. One hundred and eighty patients with type 2 diabetes mellitus will be randomized into three groups (needle acupuncture, verum laser acupuncture, and placebo laser acupuncture). We hypothesize that needle and laser acupuncture have beneficial effects on electrophysiological parameters and clinical and subjective symptoms in relation to DPN in comparison with placebo. The ACUDIN trial aims at investigating whether classical needle acupuncture and/or laser acupuncture are efficacious in the treatment of DPN. For the purpose of an objective parameter, NCS were chosen as outcome measures. Acupuncture treatment may potentially improve patients' quality of life and reduce the socio-economic burden caused by DPN. German Clinical Trial Register (DRKS), No. DRKS00008562 , trial search portal of the WHO ( http://apps.who.int/trialsearch/ ).
[Clinical observation on common peroneal nerve palsy treated with comprehensive therapy].
Yang, Li-Juan; Liu, Ya-Li; Wang, Shu-Bin; Jin, Zhi-Gao
2014-04-01
To compare the difference of the clinical efficacy on common peroneal palsy between the comprehensive therapy of electroacupuncture, moxibustion and moving cupping method and western medication. Ninety cases of common peroneal nerve palsy were randomized into a comprehensive therapy group and a western medication group, 45 cases in each one. In the comprehensive therapy group, electroacupuncture was applied to Yanglingquan (GB 34), Zusanli (ST 36), Xuanzhong (GB 39), Jiexi (ST 41), Taichong (LR 3), Zulinqi (GB 41) and the others, combined with warm moxibustion and moving cupping on the lateral side of the affected leg. The comprehensive therapy was used once a day. In the western medication group, vitamin B1 , 10 mg each time, 3 times a day; and mecobalamine, 0. 5 mg each time, three times a day were prescribed for oral administration. In the two groups, 15 days made one session, and the efficacy was observed after 2 sessions treatment. The total effective rate of the improvement of sensory function and motor nerve function was 97. 8% (44/45) in the comprehensive therapy group and was 82. 2% (37/ 45) in the western medication. The efficacy in the comprehensive therapy group was better than that of the western medication (P<0. 01). The electrophysiological examination showed that the amplitude of motor conduction of deep peroneal nerve and that of sensory conduction of surficial peroneal nerve after treatment were improved remarkably as compared with those before treatment in the comprehensive therapy group (both P<0. 05). The amplitude of motor conduction of deep peroneal nerve was improved significantly in the comprehensive therapy group as compared with that in the western medication group (P<0. 05). The comprehensive therapy of electroacupuncture, moxibustion and moving cupping method achieves the significant efficacy on common peroneal nerve palsy as compared with western medication.
2011-01-01
Introduction Occipital peripheral nerve stimulation is an interventional pain management therapy that provides beneficial results in the treatment of refractory chronic occipital neuralgia. Herein we present a first-of-its-kind case study of a patient with neurofibromatosis type 1 and bilateral occipital neuralgia treated with occipital peripheral nerve stimulation. Case presentation A 42-year-old Caucasian woman presented with bilateral occipital neuralgia refractory to various conventional treatments, and she was referred for possible treatment with occipital peripheral nerve stimulation. She was found to be a suitable candidate for the procedure, and she underwent implantation of two octapolar stimulating leads and a rechargeable, programmable, implantable generator. The intensity, severity, and frequency of her symptoms resolved by more than 80%, but an infection developed at the implantation site two months after the procedure that required explantation and reimplantation of new stimulating leads three months later. To date she continues to experience symptom resolution of more than 60%. Conclusion These results demonstrate the significance of peripheral nerve stimulation in the management of refractory occipital neuralgias in patients with neurofibromatosis type 1 and the possible role of neurofibromata in the development of occipital neuralgia in these patients. PMID:21569290
Functional significance of the pattern of renal sympathetic nerve activation.
Dibona, G F; Sawin, L L
1999-08-01
To assess the renal functional significance of the pattern of renal sympathetic nerve activation, computer-generated stimulus patterns (delivered at constant integrated voltage) were applied to the decentralized renal sympathetic nerve bundle and renal hemodynamic and excretory responses determined in anesthetized rats. When delivered at the same integrated voltage, stimulus patterns resembling those observed in in vivo multifiber recordings of renal sympathetic nerve activity (diamond-wave patterns) produced greater renal vasoconstrictor responses than conventional square-wave patterns. Within diamond-wave patterns, increasing integrated voltage by increasing amplitude produced twofold greater renal vasoconstrictor responses than by increasing duration. With similar integrated voltages that were subthreshold for renal vasoconstriction, neither diamond- nor square-wave pattern altered glomerular filtration rate, whereas diamond- but not square-wave pattern reversibly decreased urinary sodium excretion by 25 +/- 3%. At the same number of pulses per second, intermittent stimulation produced faster and greater renal vasoconstriction than continuous stimulation. At the same number of pulses per second, increases in rest period during intermittent stimulation proportionally augmented the renal vasoconstrictor response compared with that observed with continuous stimulation; the maximum augmentation of 55% occurred at a rest period of 500 ms. These results indicate that the pattern of renal sympathetic nerve stimulation (activity) significantly influences the rapidity, magnitude, and selectivity of the renal vascular and tubular responses.
De, Abhishek; Hasanoor Reja, Abu Hena; Aggarwal, Ishad; Sen, Sumit; Sil, Amrita; Bhattacharya, Basudev; Sharma, Nidhi; Ansari, Asad; Sarda, Aarti; Chatterjee, Gobinda; Das, Sudip
2017-01-01
Pure neural leprosy (PNL) still remains a diagnostic challenge because of the absence of sine qua non skin lesions of leprosy and a confirmatory diagnostic method. The authors had earlier described a simple yet objective technique of combining fine needle aspiration cytology (FNAC) coupled with a multiplex polymerase chain reaction (PCR) in a pilot study, wherein the technique showed promise of a reliable diagnostic tool. In the pursuit of further evidence, the authors carried out a 4-year study with PNL cases to find the efficacy and reliability of the said method in a larger sample size. This study was conducted to find the efficacy, reliability, and reproducibility of FNAC coupled with multiplex PCR and Ziehl-Neelsen (ZN) staining in identifying the cases of PNL. All cases that were suspected to be suffering from PNL, following evaluation by two independent observers were included in the study and were subjected to FNAC from the affected nerve, and the aspirates were evaluated for cytology, ZN staining, and multiplex PCR for Mycobacterium leprae genome. In addition, serum anti-PGL1 levels were also performed in all the study subjects. Fifteen non-PNL cases were also included in the control arm. A total of 47 cases were included in the test arm and subjected to FNAC. Conventional ZN staining could demonstrate acid-fast bacilli (AFB) in only 15 out of 47 cases (31.91%) while M. leprae DNA could be elicited in 37 (78.72%) cases by the multiplex PCR. Only 13 (27.65%) out of 47 cases showed anti-PGLI-1 antibody positivity. On cytological examination of the nerve aspirates, only 11 (23.40%) cases showed epithelioid cells whereas nonspecific inflammation was seen in 26 (75.60%) cases. The results of this study conducted over a larger sample size corroborate with the findings of our pilot study. In a resource poor set up, FNAC in combination with ZN staining and multiplex PCR is a rapid, simple, and easily performed test, which can give a reproducible and objective diagnosis in cases of PNL.
Notarnicola, A; Maccagnano, G; Gallone, M F; Mastromauro, L; Rifino, F; Pesce, V; Covelli, I; Moretti, B
2018-01-01
The physiotherapy treatment of low back pain (LBP) with physical stimulation offers different possibilities of application. Until now, the physical therapies used in LBP are laser therapy, ultrasonotherapy and currents. We conducted a clinical trial in order to verify whether shockwave therapy, which is very effective in treating tendinopathies and fracture consolidation delays, leads to clinical and electromyographic improvement in patients affected by LBP. We randomized thirty patients affected by LBP treated with shock waves (shockwave group) or a standard protocol characterized by rehabilitative exercises (control group). At one and three months, the patients treated with shockwave therapy showed clinical improvement measured by VAS scales (p=0.002; p= 0.02), and disability evaluated with Roland scales (p=0.002; p=0.002) and Oswestry (p=0.002; p=0.002). At three months, the patients treated with shock waves, showed a significant improvement in terms of values of amplitude of the sensory nerve conduction velocity (SNCV) of the plantar medialis nerve (left: p=0.007; right: p=0.04), the motor nerve muscular conduction (MNCV) of the deep peroneal nerve (left: p=0.28; right: p=0.01) and recruitment of motor units of finger brevis extensor (left: p = 0.02; right: p=0.006). In the control group, there was a trend to increase the clinical and electromyographic results without statistical significance. The preliminary results suggest a good applicability of shockwave therapy in the treatment of LBP, in accordance with the antiinflammatory, antalgic, decontracting effects and remodeling of the nerve fiber damage verified in previous studies conducted on other pathological models. Future research will allow us to verify the integration of this therapy into a rehabilitation protocol combined with other physical therapies.
Herrera, Esperanza; Sandoval, Maria Cristina; Camargo, Diana M; Salvini, Tania F
2011-01-01
Different cryotherapy modalities have distinct effects on sensory and motor nerve conduction parameters. However, it is unclear how these parameters change during the post-cooling period and how the exercise carried out in this period would influence the recovery of nerve conduction velocity (NCV). To compare the effects of three cryotherapy modalities on post-cooling NCV and to analyze the effect of walking on the recovery of sensory and motor NCV. Thirty six healthy young subjects were randomly allocated into three groups: ice massage (n=12), ice pack (n=12) and cold water immersion (n=12). The modalities were applied to the right leg. The subjects of each modality group were again randomized to perform a post-cooling activity: a) 30 min rest, b) walking 15 min followed by 15 min rest. The NCV of sural (sensory) and posterior tibial (motor) nerves was evaluated. Initial (pre-cooling) and final (30 min post-cooling) NCV were compared using a paired t-test. The effects of the modalities and the post-cooling activities on NCV were evaluated by an analysis of covariance. The significance level was α=0.05. There was a significant difference between immersion and ice massage on final sensory NCV (p=0.009). Ice pack and ice massage showed similar effects (p>0.05). Walking accelerated the recovery of sensory and motor NCV, regardless of the modality previously applied (p<0.0001). Cold water immersion was the most effective modality for maintaining reduced sensory nerve conduction after cooling. Walking after cooling, with any of the three modalities, enhances the recovery of sensory and motor NCV.
Hotta, N; Toyota, T; Matsuoka, K; Shigeta, Y; Kikkawa, R; Kaneko, T; Takahashi, A; Sugimura, K; Koike, Y; Ishii, J; Sakamoto, N
2001-10-01
The purpose of this study was to evaluate the efficacy of fidarestat, a novel aldose reductase (AR) inhibitor, in a double-blind placebo controlled study in patients with type 1 and type 2 diabetes and associated peripheral neuropathy. A total of 279 patients with diabetic neuropathy were treated with placebo or fidarestat at a daily dose of 1 mg for 52 weeks. The efficacy evaluation was based on change in electrophysiological measurements of median and tibial motor nerve conduction velocity, F-wave minimum latency, F-wave conduction velocity (FCV), and median sensory nerve conduction velocity (forearm and distal), as well as an assessment of subjective symptoms. Over the course of the study, five of the eight electrophysiological measures assessed showed significant improvement from baseline in the fidarestat-treated group, whereas no measure showed significant deterioration. In contrast, in the placebo group, no electrophysiological measure was improved, and one measure significantly deteriorated (i.e., median nerve FCV). At the study conclusion, the fidarestat-treated group was significantly improved compared with the placebo group in two electrophysiological measures (i.e., median nerve FCV and minimal latency). Subjective symptoms (including numbness, spontaneous pain, sensation of rigidity, paresthesia in the sole upon walking, heaviness in the foot, and hypesthesia) benefited from fidarestat treatment, and all were significantly improved in the treated versus placebo group at the study conclusion. At the dose used, fidarestat was well tolerated, with an adverse event profile that did not significantly differ from that seen in the placebo group. The effects of fidarestat-treatment on nerve conduction and the subjective symptoms of diabetic neuropathy provide evidence that this treatment alters the progression of diabetic neuropathy.
Lange-Maia, Brittney S; Newman, Anne B; Jakicic, John M; Cauley, Jane A; Boudreau, Robert M; Schwartz, Ann V; Simonsick, Eleanor M; Satterfield, Suzanne; Vinik, Aaron I; Zivkovic, Sasa; Harris, Tamara B; Strotmeyer, Elsa S
2017-10-01
Age-related peripheral nervous system (PNS) impairments are highly prevalent in older adults. Although sensorimotor and cardiovascular autonomic function have been shown to be related in persons with diabetes, the nature of the relationship in general community-dwelling older adult populations is unknown. Health, Aging and Body Composition participants (n=2399, age=76.5±2.9years, 52% women, 38% black) underwent peripheral nerve testing at the 2000/01 clinic visit. Nerve conduction amplitude and velocity were measured at the peroneal motor nerve. Sensory nerve function was assessed with vibration detection threshold and monofilament (1.4-g/10-g) testing at the big toe. Symptoms of lower-extremity peripheral neuropathy were collected by self-report. Cardiovascular autonomic function indicators included postural hypotension, resting heart rate (HR), as well as HR response to and recovery from submaximal exercise testing (400m walk). Multivariable modeling adjusted for demographic/lifestyle factors, medication use and comorbid conditions. In fully adjusted models, poor motor nerve conduction velocity (<40m/s) was associated with greater odds of postural hypotension, (OR=1.6, 95% CI: 1.0-2.5), while poor motor amplitude (<1mV) was associated with 2.3beats/min (p=0.003) higher resting HR. No associations were observed between sensory nerve function or symptoms of peripheral neuropathy and indicators of cardiovascular autonomic function. Motor nerve function and indicators of cardiovascular autonomic function remained significantly related even after considering many potentially shared risk factors. Future studies should investigate common underlying processes for developing multiple PNS impairments in older adults. Copyright © 2017 Elsevier Inc. All rights reserved.
Hernández-Pedro, N.; Fernández-González- Aragón, M.C.; Saavedra-Pérez, D.; Campos-Parra, A.D.; Ríos-Trejo, M.Á.; Cerón-Lizárraga, T.; Martínez-Barrera, L.; Pineda, B.; Ordóñez, G.; Ortiz-Plata, A.; Granados-Soto, V.; Sotelo, J.
2011-01-01
Objective: To evaluate the effect of all-trans retinoic acid (ATRA) as treatment for chemotherapy-induced peripheral neuropathy in an experimental animal model and in a randomized, double-blinded, controlled trial in patients with non-small-cell lung cancer (NSCLC). Methods: Forty male Wistar rats were randomized in 5 groups: group A, control; groups B and C, treated with cisplatin; and groups D and E, treated with paclitaxel. ATRA (20 mg/kg PO) was administered for 15 days in groups C and E. We evaluated neuropathy and nerve regeneration–related morphologic changes in sciatic nerve, the concentration of nerve growth factor (NGF), and retinoic acid receptor (RAR)–α and RAR-β expression. In addition, 95 patients with NSCLC under chemotherapy treatment were randomized to either ATRA (20 mg/m2/d) or placebo. Serum NGF, neurophysiologic tests, and clinical neurotoxicity were assessed. Results: The experimental animals developed neuropathy and axonal degeneration, associated with decreased NGF levels in peripheral nerves. Treatment with ATRA reversed sensorial changes and nerve morphology; this was associated with increased NGF levels and RAR-β expression. Patients treated with chemotherapy had clinical neuropathy and axonal loss assessed by neurophysiology, which was related to decreased NGF levels. ATRA reduced axonal degeneration demonstrated by nerve conduction velocity and clinical manifestations of neuropathy grades ≥2. Conclusions: ATRA reduced chemotherapy-induced experimental neuropathy, increased NGF levels, and induced RAR-β expression in nerve. In patients, reduction of NGF in serum was associated with the severity of neuropathy; ATRA treatment reduced the electrophysiologic alterations. Classification of evidence: This study provides Class II evidence that ATRA improves nerve conduction in patients with chemotherapy-induced peripheral neuropathy. Neurology® 2011;77:987–995 PMID:21865574
Challenges associated with nerve conduction block using kilohertz electrical stimulation
NASA Astrophysics Data System (ADS)
Patel, Yogi A.; Butera, Robert J.
2018-06-01
Neuromodulation therapies, which electrically stimulate parts of the nervous system, have traditionally attempted to activate neurons or axons to restore function or alleviate disease symptoms. In stark contrast to this approach is inhibiting neural activity to relieve disease symptoms and/or restore homeostasis. One potential approach is kilohertz electrical stimulation (KES) of peripheral nerves—which enables a rapid, reversible, and localized block of conduction. This review highlights the existing scientific and clinical utility of KES and discusses the technical and physiological challenges that must be addressed for successful translation of KES nerve conduction block therapies.
[Anatomic rationale for clinical efficacy of intraosseous mental nerve anesthesia].
Rabinovich, S A; Vasil'ev, Yu L; Kuzin, A N
2018-01-01
The aim of the study was to prove the anatomical and clinical effectiveness of the modified anesthesia of mental nerve. The effectiveness of conductive anesthesia near the mental foramen was objectively evaluated using the electric pulp test (EPT) in 100 volunteers of both sexes, aged 35-43 years. Wet anterior mandible preparations obtained from 350 cadavers aged 18-74 years were also studied. EPT value after local mental anesthesia conducted according to Malamed C. using 4% articain solution of local anesthetic with vasoconstrictor concentration of 1:200.000 after 2 minutes was 93±0.82 mA, after 4 minutes - 188±1.26 mA. Yield variability indicators of intraosseous mental nerve anesthesia was slightly higher varying from 94.11 mA to 96.61 mA after 2 minutes and from 197.4 to 199.92 mA after 4 minutes survey. The study showed the efficiency and predictability of intraosseous anesthesia of the mental nerve.
Hao, Wu; Tashiro, Syoichi; Hasegawa, Tomoka; Sato, Yuiko; Kobayashi, Tami; Tando, Toshimi; Katsuyama, Eri; Fujie, Atsuhiro; Watanabe, Ryuichi; Morita, Mayu; Miyamoto, Kana; Morioka, Hideo; Nakamura, Masaya; Matsumoto, Morio; Amizuka, Norio; Toyama, Yoshiaki; Miyamoto, Takeshi
2015-01-01
Diabetes mellitus (DM) is frequently accompanied by complications, such as peripheral nerve neuropathy. Schwann cells play a pivotal role in regulating peripheral nerve function and conduction velocity; however, changes in Schwann cell differentiation status in DM are not fully understood. Here, we report that Schwann cells de-differentiate into immature cells under hyperglycemic conditions as a result of sorbitol accumulation and decreased Igf1 expression in those cells. We found that de-differentiated Schwann cells could be re-differentiated in vitro into mature cells by treatment with an aldose reductase inhibitor, to reduce sorbitol levels, or with vitamin D3, to elevate Igf1 expression. In vivo DM models exhibited significantly reduced nerve function and conduction, Schwann cell de-differentiation, peripheral nerve de-myelination, and all conditions were significantly rescued by aldose reductase inhibitor or vitamin D3 administration. These findings reveal mechanisms underlying pathological changes in Schwann cells seen in DM and suggest ways to treat neurological conditions associated with this condition. PMID:25998127
Li, Mingdi; Huang, Da; Liu, Xiaoxing; Lin, Lan
2015-01-01
Tang-tong-fang (TTF) is a Chinese herbal formula that has been shown to be beneficial in diabetic peripheral neuropathy (DPN), a common complication secondary to diabetic microvascular injury. However, the underlying mechanism of protection in nerve ischemia provided by TTF is still unclear. We hypothesized that TTF alleviates DPN via inhibition of ICAM-1 expression. Therefore, we tested the effect of TTF in a previously established DPN model, in which nerve injury was induced by ischemia/reperfusion in streptozotocin-induced diabetic rats. We found that the conduction velocity and amplitude of action potentials of sciatic nerve conduction were reduced in the DPN model group but were rescued by TTF treatment. In addition, TTF treatment also attenuated the effect of DPN on other parameters including histology and ultrastructural changes, expression of ICAM-1, MPO, and TNF-α in rat sciatic nerves, and plasma sICAM-1 and MPO levels. Together, our data suggest that TTF treatment may alleviate DPN via ICAM-1 inhibition. PMID:26539228
Electrodiagnostic Examination of the Tibial Nerve in Clinically Normal Ferrets
Bianchi, Ezio; Callegari, Daniela; Ravera, Manuela; Dondi, Maurizio
2010-01-01
Tibial nerves of 10 normal domestic ferrets (Mustela putorius furo) were evaluated by means of electrodiagnostic tests: motor nerve conduction studies (MNCSs), supramaximal repetitive nerve stimulation (SRNS), F waves, and cord dorsum potentials (CDPs). Values of conduction velocity, proximal and distal compound muscular action potentials, and amplitudes of MNCS were, respectively, 63.25 ± 7.56 m/sec, 10.79 ± 2.75 mV, and 13.02 ± 3.41 mV. Mean decrements in amplitude and area of compound muscular action potentials of wave 9 with low frequency SRNS were 0.3 ± 3.83% and 0.1 ± 3.51%. The minimum latency of the F waves and the F ratio were, respectively, 8.49 ± 0.65 ms and 1.92 ± 0.17. Onset latency of CDP was 1.99 ± 0.03 ms. These tests may help in diagnosing neuromuscular disorders and in better characterizing the hindlimb paresis reported in many ferrets with systemic illnesses. PMID:20706690
Innervation of the wrist joint and surgical perspectives of denervation.
Van de Pol, Gerrit J; Koudstaal, Maarten J; Schuurman, Arnold H; Bleys, Ronald L A W
2006-01-01
Because our experience with the techniques used in denervation surgery of the wrist joint often has proven insufficient in treating chronic pain we conducted an anatomic study to clarify the exact contributions of the nerves supplying the wrist joint. Our goal was to reveal all periosteal and capsular nerve connections and if necessary adjust our technique used in denervation surgery. Innervation of the wrist joint was investigated by microdissection and histologic examination of 18 human wrists. An acetylcholinesterase method was used to identify the nerves, both in whole-mount preparations and in sections. We found that the main innervation to the wrist capsule and periosteal nerve network came from the anterior interosseous nerve, lateral antebrachial cutaneous nerve, and posterior interosseous nerve. The palmar cutaneous branch of the median nerve, the deep branch of the ulnar nerve, the superficial branch of the radial nerve, and the dorsal branch of the ulnar nerve also were found to have connections with the capsule. The periosteal nerve branches did not appear to play a major role in the innervation of the capsule and ligaments; here the specific articular nerve branches proved more important. The posterior and medial antebrachial cutaneous nerves did not connect to the wrist capsule or periosteum but rather terminated in the extensor and flexor retinaculum. Based on our findings we propose to denervate the wrist by making 2 incisions. With one palmar and one dorsal incision it should be possible to disconnect the periosteum from the capsule and interrupt the majority of the capsular nerve branches.
Peripheral neuropathy in patients with myotonic dystrophy type 2.
Leonardis, L
2017-05-01
Myotonic dystrophy type 2 (dystrophia myotonica type 2-DM2) is an autosomal dominant multi-organ disorder. The involvement of the peripheral nervous system was found in 25%-45% of patients with myotonic dystrophy type 1, although limited data are available concerning polyneuropathy in patients with DM2, which was the aim of this study with a thorough presentation of the cases with peripheral neuropathy. Patients with genetically confirmed DM2 underwent motor nerve conduction studies of the median, ulnar, tibial and fibular nerves and sensory nerve conduction studies of the median (second finger), ulnar (fifth finger), radial (forearm) and sural nerves. Seventeen adult patients with DM2 participated in the study. Fifty-three percent (9/17) of our patients had abnormality of one or more attributes (latency, amplitude or conduction velocity) in two or more separate nerves. Four types of neuropathies were found: (i) predominantly axonal motor and sensory polyneuropathy, (ii) motor polyneuropathy, (iii) predominantly demyelinating motor and sensory polyneuropathy and (iv) mutilating polyneuropathy with ulcers. The most common forms are axonal motor and sensory polyneuropathy (29%) and motor neuropathy (18% of all examined patients). No correlations were found between the presence of neuropathy and age, CCTG repeats, blood glucose or HbA1C. Peripheral neuropathy is common in patients with DM2 and presents one of the multisystemic manifestations of DM2. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Suzuki, K; Saito, N; Sakata, Y; Toyota, T; Goto, Y
1990-11-01
A new prostaglandin E1 analogue, TFC-612, was given orally to 2 month-old spontaneously diabetic GK (Goto-Kakizaki) rats for 3 months to ascertain its effects on reduced motor nerve conduction velocity (MCV). A high dose of this compound (0.3 mg/kg body weight) significantly restored MCV after 2 and 3 months of administration, although the low dose (0.03 mg/kg body weight) did not. In addition, 1 month administration of TFC-612 significantly improved the reduced MCV in aged (5 month-old) GK rats only in the high dose group (0.3 mg/kg body weight), but not in the low dose group (0.03 mg/kg body weight). Although TFC-612 significantly suppressed sorbitol accumulation in the sciatic nerves of GK rats in a dose dependent manner after 3 months administration, this suppression was not observed after either 2 months administration to 2 month-old GK rats or after 1 month administration to 5 month-old GK rats. Fasting blood glucose levels of all GK rats remained high throughout the experiments, regardless of TFC-612 administration. TFC-612's improvement on reduced motor nerve conduction velocity was related partly to suppression of sorbitol accumulation, but other factors, including microcirculation, may contribute significantly to this effect. These results suggest that TFC-612 may be beneficial in the treatment of diabetic nerve impairment.
Byrne, N. G.; Muir, T. C.
1985-01-01
The response of the bovine retractor penis (BRP) to stimulation of non-adrenergic, non-cholinergic (NANC) inhibitory nerves and to an inhibitory extract prepared from this muscle have been studied using intracellular microelectrode, sucrose gap and conventional mechanical recording techniques. Both inhibitory nerve stimulation and inhibitory extract hyperpolarized the membrane potential and relaxed spontaneous or guanethidine (3 X 10(-5) M)-induced tone. These effects were accompanied by an increase in membrane resistance. Following membrane potential displacement from an average value of -53 +/- 7 mV (n = 184; Byrne & Muir, 1984) inhibitory potentials to nerve stimulation were abolished at approximately -30 mV; there was no evidence of reversal. Displacement by inward hyperpolarizing current over the range -45 to -60 mV increased the inhibitory response to nerve stimulation and to inhibitory extract; at more negative potential values (above approximately -60 mV) the inhibitory potential decreased and was abolished (approximately -103 mV). There was no evidence of reversal. Removal of [K+]o reversibly reduced hyperpolarization to nerve stimulation and inhibitory extract. No enhancement was observed. Increasing the [K+]o to 20 mM reduced the inhibitory potential to nerve stimulation but this was restored by passive membrane hyperpolarization. Inhibitory potentials were obtained at membrane potential values exceeding that of the estimated EK (-49 mV). [Cl-]o-free or [Cl-]o-deficient solutions reduced and abolished (after some 20-25 min) the hyperpolarization produced by inhibitory nerve stimulation or inhibitory extract. The inhibitory potential amplitude following nerve stimulation was not restored by passive displacement of the membrane potential from -26 to -104 mV approximately. Ouabain (1-5 X 10(-5) M) reduced then (45-60 min later) abolished the inhibitory potential to nerve stimulation. The effects of this drug on the extract were not investigated. It is concluded that the inhibitory response to nerve stimulation and extract in the BRP may involve several ionic species. However, unlike that in gastrointestinal muscles the NANC response in the BRP is accompanied by an increased membrane resistance and does not primarily involve K+. The underlying mechanisms for the inhibitory response to both NANC nerve stimulation and inhibitory extract appear to be similar, compatible with the view that the latter may contain the inhibitory transmitter released from these nerves in this tissue. PMID:4027462
Ahadi, Tannaz; Raissi, Gholam Reza; Yavari, Masood; Majidi, Lobat
2016-01-01
Background: Two main muscles studied in the hand for evaluation of median nerve injuries are opponens pollicis (OP) and abductor pollicis brevis (APB). However, Riché-Cannieu communicating branch (RCCB) may limit the use of these muscles in electrodiagnosis. This condition is confusing in the case of median nerve injuries. This study was conducted to evaluate the prevalence of RCCB. Methods: Twenty-three consecutive cases of complete median nerve injury were studied. Evoked responses via stimulation of median and ulnar nerves in the wrist and recording with needle in the thenar area were studied. Results: Of the patients, 82.6% exhibited RCCB. In 14 (60.8%) cases the OP and in 19(82.6%) cases APB was supplied by the ulnar nerve. Conclusion: RCCB was detected to be 60.8% in OP and 82.6% in APB, so OP is preferable to APB in the study of median nerve. PMID:27390694
Economic analysis of routine neuromonitoring of recurrent laryngeal nerve in total thyroidectomy.
Sanabria, Álvaro; Ramírez, Adonis
2015-01-01
Thyroidectomy is a common surgery. Routine searching of the recurrent laryngeal nerve is the most important strategy to avoid palsy. Neuromonitoring has been recommended to decrease recurrent laryngeal nerve palsy. To assess if neuromonitoring of recurrent laryngeal nerve during thyroidectomy is cost-effective in a developing country. We designed a decision analysis to assess the cost-effectiveness of recurrent laryngeal nerve neuromonitoring. For probabilities, we used data from a meta-analysis. Utility was measured using preference values. We considered direct costs. We conducted a deterministic and a probabilistic analysis. We did not find differences in utility between arms. The frequency of recurrent laryngeal nerve injury was 1% in the neuromonitor group and 1.6% for the standard group. Thyroidectomy without monitoring was the less expensive alternative. The incremental cost-effectiveness ratio was COP$ 9,112,065. Routine neuromonitoring in total thyroidectomy with low risk of recurrent laryngeal nerve injury is neither cost-useful nor cost-effective in the Colombian health system.
Wang, Caifeng; Oh, Sangjin; Lee, Hyun Ah; Kang, Jieun; Jeong, Ki-Jae; Kang, Seon Woo; Hwang, Dae Youn; Lee, Jaebeom
2017-06-01
Carbon nanotubes, with their unique and outstanding properties, such as strong mechanical strength and high electrical conductivity, have become very popular for the repair of tissues, particularly for those requiring electrical stimuli. Polydimethylsiloxane (PDMS)-based elastomers have been used in a wide range of biomedical applications because of their optical transparency, physiological inertness, blood compatibility, non-toxicity, and gas permeability. In present study, most of artificial nerve guidance conduits (ANGCs) are not transparent. It is hard to confirm the position of two stumps of damaged nerve during nerve surgery and the conduits must be cut open again to observe regenerative nerves after surgery. Thus, a novel preparation method was utilized to produce a transparent sheet using PDMS and multiwalled carbon nanotubes (MWNTs) via printing transfer method. Characterization of the PDMS/MWNT (PM) sheets revealed their unique physicochemical properties, such as superior mechanical strength, a certain degree of electrical conductivity, and high transparency. Characterization of the in vitro and in vivo usability was evaluated. PM sheets showed high biocompatibility and adhesive ability. In vivo feasibility tests of rat brain tissue and sciatic nerve revealed the high transparency of PM sheets, suggesting that it can be used in the further development of ANGCs. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 1736-1745, 2017. © 2017 Wiley Periodicals, Inc.
[Clinical and electrophysiological findings in carpal tunnel syndrome].
Kohara, Nobuo
2007-11-01
Carpal tunnel syndrome (CTS) is the most common nerve entrapment disorder. The clinical features of CTS are variable, but usually include pain and paresthesia in the thumb, first two fingers, and the radial-half of the ring finger. Paresthesia and sensory deficits might involve the entire palm area in some cases. Pain frequently radiate proximally into the forearm, and occasionally to the shoulder. Many patients experience pain at night and are awakened by abnormal sensations. Shaking hand relief the symptom. The two classic tests for nerve compression at the wrist are the Tinel test and the Phalen maneuver, which diagnostic value is limited. Golden standard for the diagnosis is the combination of the clinical findings and the electrophysiological study. Routine median nerve conduction study is valuable. Prolonged terminal latency of motor or sensory nerve would be found in most CTS hands. If the routine study showed equivocal, more sensitive methods are needed. Those include segmental sensory conduction study across the carpal tunnel by median stimulation at midpalm, a comparison of median and ulnar sensory nerve latencies at ring finger and a comparison of median and radial sensory nerve latencies at thumb. A difference between the median motor latency to the second lumbrical and the ulnar motor latency to the interossei muscles has also diagnostic value in some cases. In addition, inching method can localized the compression site. Using these techniques, the diagnosis of CTS would become more reliable.
Leibig, Nico; Boyle, Veronika; Kraus, Daniel; Stark, Gerhard Bjoern; Penna, Vincenzo
2015-03-01
Peripheral nerve regeneration over longer distances through conduits is limited. In the presented study, critical size nerve gap bridging with a poly-DL-lactide-ε-caprolactone (PLC) conduit was combined with application of C3 toxin to facilitate axonal sprouting. The PLC filled with fibrin (n = 10) and fibrin gel loaded with 1-μg C3-C2I and 2-μg C2II (n = 10) were compared to autologous nerve grafts (n = 10) in a 15-mm sciatic nerve gap lesion model of the rat. Functional and electrophysiological analyses were performed before histological evaluation. Evaluation of motor function and nerve conduction velocity at 16 weeks revealed no differences between the groups. All histological parameters and muscle weight were significantly elevated in nerve graft group. No differences were observed in both PLC groups. The PLCs are permissive for nerve regeneration over a 15-mm defect in rats. Intraluminal application of C3 toxin did not lead to significant enhancement of nerve sprouting.
Massive nerve root enlargement in chronic inflammatory demyelinating polyneuropathy.
Schady, W; Goulding, P J; Lecky, B R; King, R H; Smith, C M
1996-01-01
OBJECTIVE: To report three patients with chronic inflammatory demyelinating polyneuropathy (CIDP) presenting with symptoms suggestive of cervical (one patient) and lumbar root disease. METHODS: Nerve conduction studies, EMG, and nerve biopsy were carried out, having found the nerve roots to be very enlarged on MRI, CT myelography, and at surgery. RESULTS: Clinically, peripheral nerve thickening was slight or absent. Subsequently one patient developed facial nerve hypertrophy. This was mistaken for an inner ear tumour and biopsied, with consequent facial palsy. Neurophysiological tests suggested a demyelinating polyneuropathy. Sural nerve biopsy showed in all cases some loss of myelinated fibres, inflammatory cell infiltration, and a few onion bulbs. Hypertrophic changes were much more prominent on posterior nerve root biopsy in one patient: many fibres were surrounded by several layers of Schwann cell cytoplasm. There was an excellent response to steroids in two patients but not in the third (most advanced) patient, who has benefited only marginally from intravenous immunoglobulin therapy. CONCLUSIONS: MRI of the cauda equina may be a useful adjunct in the diagnosis of CIDP. Images PMID:8971116
Recording of electroneurograms from the nerves innervating the pancreas of a dog.
Rozman, J; Zorko, B; Bunc, M
2001-12-15
Electroneurograms (ENGs) from the vagus, splanchnic and pancreatic nerves innervating the pancreas of a dog, were recorded with chronically implanted silicone multi-electrode circular cuffs in an intact pancreas and in a pancreas partly disabled with alloxan. The cuffs contained 33 platinum electrodes (0.6x1.5 mm) arranged in three parallel circular groups integrated into the inner surface of the cuff. Each circular group contained 11 electrodes at a distance of 0.5 mm apart, with 6 mm between the circular groups. The cuffs had an inner diameter of 2.5 mm and the length of 18 mm. In a 2-year study, the cuffs were implanted into two adult Beagle dogs (one female and one male). In the vagus nerve, the cuff was installed on the nerve at the neck, whilst in the splanchnic nerve, the cuff was installed on the nerve before the celiac ganglion, and in the pancreatic nerve, the cuff was installed on the nerve just before it enters the pancreas. In each of the three implanted cuffs, the electrodes of the central circular group were connected to each other and this signal provided one input to a multi-channel ENG amplifying system. The electrodes of each of the two outer spiral groups were connected to each other and then both these groups were short-circuited. This signal then provided another input to the multi-channel ENG amplifying system. The ENG amplifying system was designed to amplify the ENGs 100000 times and to pass frequencies of between 500 and 10 kHz. In our study, three recordings in each animal were conducted. Recordings in the intact pancreas were conducted 2 and 6 months after the implantation, while the recording in the partly disabled pancreas, was conducted 10 months after the implantation and 10 days after the disablement. Due to the fact that the results obtained in both animals were actually quite similar, we present the results of the recordings obtained in one animal. In both animals the cuffs were left implanted for more than 1 year and were used for pancreatic stimulation, although this is not in this paper. The results show that cuffs implanted chronically on the nerves innervating the pancreas of a dog could reliably record the ENGs. This information could be used effectively in further study of pancreatic innervation and its function. Moreover, the results suggest that cuffs could also be useful in recording the ENGs from other nerves of the autonomic nervous system that innervate various glands and internal organs.
Double peak sensory nerve action potentials to single stimuli in nerve conduction studies.
Leote, Joao; Pereira, Pedro; Valls-Sole, Josep
2017-05-01
In humans, sensory nerve action potentials (SNAPs) can show 2 separate deflections, i.e., double peak potentials (DPp), which necessarily means that 1 peak is delayed with respect to the other. DPps may have various origins and be due to either physical or physiological properties. We review the nature of commonly encountered DPps in clinical practice, provide the most likely interpretations for their physiological origin, and assess their reproducibility and clinical utility. We classified the DPps into 3 categories: (1) simultaneous anodal and cathodal stimulation. (2) simultaneous recording from 2 different nerves at the same site, and (3) SNAP desynchronization. Although the recording of DPps is not a standardized neurophysiological method, their study brings interesting cues about the physiology of nerve stimulation and paves the way for clinical application of such an observation. Muscle Nerve 55: 619-625, 2017. © 2016 Wiley Periodicals, Inc.
Attempt of peripheral nerve reconstruction during lung cancer surgery.
Li, Hanyue; Hu, Yingjie; Huang, Jia; Yang, Yunhai; Xing, Kaichen; Luo, Qingquan
2018-05-01
Vagus nerve and recurrent laryngeal nerve (RLN) injury are not rare complications of lung cancer surgery and can cause lethal consequences. Until now, no optimal method other than paying greater attention during surgery has been available. Four patients underwent lung surgery that involved RLN or vagus nerve injury. The left RLN or vagus nerve was cut off and then reconstructed immediately during surgery. Two patients underwent direct anastomosis, while the remaining two underwent phrenic nerve replacing tension-relieving anastomosis. All patients were able to speak immediately after recovery. No or minimal glottal gap was observed during laryngoscopy conducted on the second day after surgery. Most patients achieved full recovery of voice quality. Immediate reconstruction of RLN is technically feasible and can be carried out with satisfying short-term and long-term outcomes. © 2018 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.
Multifocal sensory demyelinating neuropathy: Report of a case.
Oh, Shin J
2017-10-01
Multifocal sensory demyelinating neuropathy has not been adequately reported in the literature. A 42-year-old man with numbness of the left hand for 3 years and of the right hand for 6 months had a pure multifocal sensory neuropathy involving both hands, most prominently affecting 2-point discrimination, number writing, and object recognition of the left hand. Near-nerve needle sensory and mixed nerve conduction studies were performed on the left ulnar nerve. Studies of the left ulnar nerve documented a demyelinating neuropathy characterized by temporal dispersion and marked decrease in the amplitudes of the sensory and mixed compound nerve potentials in the above-elbow-axilla segment. With intravenous immunoglobulin treatment, there was improvement in his neuropathic condition. In this study I describe a case of multifocal sensory demyelinating neuropathy as a counterpart of multifocal motor neuropathy. Muscle Nerve 56: 825-828, 2017. © 2016 Wiley Periodicals, Inc.
Massive Oculomotor Nerve Enlargement: A Case of Presumed Schwannomatosis.
Donaldson, Laura; Rebello, Ryan; Rodriguez, Amadeo
2017-06-01
A 45-year-old man presented with a slowly progressive pupil-involving third nerve palsy. Magnetic resonance imaging (MRI) revealed a tubular lesion extending from the interpeduncular cistern through the cavernous sinus and into the left orbit where it branched into a superior and an inferior division, clearly outlining the anatomy of the third cranial nerve. Multiple other, less pronounced, enlarged cranial nerves were noted. The differential diagnosis included chronic inflammatory demyelinating polyneuropathy (CIDP), hereditary motor and sensory neuropathy (HMSN), neurofibromatosis (NF), and schwannomatosis. The absence of other muscle weakness and of sensory symptoms combined with normal peripheral nerve conduction studies effectively ruled out the hypertrophic polyneuropathies and pointed to a syndromic cause of multiple benign peripheral nerve sheath tumours (PNSTs). The authors are treating this case as presumed schwannomatosis, a syndrome similar to NF2 with much lower frequency of acoustic neuromas.
Massive Oculomotor Nerve Enlargement: A Case of Presumed Schwannomatosis
Donaldson, Laura; Rebello, Ryan; Rodriguez, Amadeo
2017-01-01
ABSTRACT A 45-year-old man presented with a slowly progressive pupil-involving third nerve palsy. Magnetic resonance imaging (MRI) revealed a tubular lesion extending from the interpeduncular cistern through the cavernous sinus and into the left orbit where it branched into a superior and an inferior division, clearly outlining the anatomy of the third cranial nerve. Multiple other, less pronounced, enlarged cranial nerves were noted. The differential diagnosis included chronic inflammatory demyelinating polyneuropathy (CIDP), hereditary motor and sensory neuropathy (HMSN), neurofibromatosis (NF), and schwannomatosis. The absence of other muscle weakness and of sensory symptoms combined with normal peripheral nerve conduction studies effectively ruled out the hypertrophic polyneuropathies and pointed to a syndromic cause of multiple benign peripheral nerve sheath tumours (PNSTs). The authors are treating this case as presumed schwannomatosis, a syndrome similar to NF2 with much lower frequency of acoustic neuromas. PMID:28512503
Tank, Jens; Heusser, Karsten; Brinkmann, Julia; Schmidt, Bernhard M.; Menne, Jan; Bauersachs, Johann; Haller, Hermann; Diedrich, André; Jordan, Jens
2016-01-01
Patients with treatment-resistant arterial hypertension exhibited profound reductions in single sympathetic vasoconstrictor fiber firing rates following renal nerve ablation. In contrast, integrated multi-unit muscle sympathetic nerve activity (MSNA) changed little or not at all. We hypothesized that conventional MSNA analysis may have missed single fiber discharges, thus, obscuring sympathetic inhibition following renal denervation. We studied patients with difficult to control arterial hypertension (age 45–74 years) before, 6 (n=11), and 12 months (n=8) following renal nerve ablation. Electrocardiogram, respiration, brachial, and finger arterial blood pressure (BP), as well as the MSNA raw MSNA signal were analyzed. We detected MSNA action potential spikes using 2 stage kurtosis wavelet denoising techniques to assess mean, median, and maximum spike rates for each beat-to-beat interval. Supine heart rate and systolic BP did not change at 6 (ΔHR: −2±3 bpm; ΔSBP: 2±9 mmHg) or at 12 months (ΔHR: −1±3 mmHg, ΔSBP: −1±9 mmHg) after renal nerve ablation. Mean burst frequency and mean spike frequency at baseline were 34±3 bursts per minute and 8±1 spikes per sec. Both measurements did not change at 6 months (−1.4±3.6 bursts/minute; −0.6±1.4 spikes per sec) or at 12 months (−2.5±4.0 bursts/minute; −2.0±1.6 spikes per sec) following renal nerve ablation. After renal nerve ablation, BP decreased in 3 out of 11 patients. BP and MSNA spike frequency changes were not correlated (slope=−0.06; p=0.369). Spike rate analysis of multi-unit MSNA neurograms further suggests that profound sympathetic inhibition is not a consistent finding following renal nerve ablation. PMID:26324745
Expression patterns and role of PTEN in rat peripheral nerve development and injury.
Chen, Hui; Xiang, Jianping; Wu, Junxia; He, Bo; Lin, Tao; Zhu, Qingtang; Liu, Xiaolin; Zheng, Canbin
2018-05-29
Studies have suggested that phosphatase and tensin homolog (PTEN) plays an important role in neuroprotection and neuronal regeneration. To better understand the potential role of PTEN with respect to peripheral nerve development and injury, we investigated the expression pattern of PTEN at different stages of rat peripheral nerve development and injury and subsequently assessed the effect of pharmacological inhibition of PTEN using bpV(pic) on axonal regeneration in a rat sciatic nerve crush injury model. During the early stages of development, PTEN exhibits low expression in neuronal cell bodies and axons. From embryonic day (E) 18.5 and postnatal day (P)5 to adult, PTEN protein becomes more detectable, with high expression in the dorsal root ganglia (DRG) and axons. PTEN expression is inhibited in peripheral nerves, preceding myelination during neuronal development and remyelination after acute nerve injury. Low PTEN expression after nerve injury promotes Akt/mammalian target of rapamycin (mTOR) signaling pathway activity. In vivo pharmacological inhibition of PTEN using bpV(pic) promoted axonal regrowth, increased the number of myelinated nerve fibers, improved locomotive recovery and enhanced the amplitude response and nerve conduction velocity following stimulation in a rat sciatic nerve crush injury model. Thus, we suggest that PTEN may play potential roles in peripheral nerve development and regeneration and that inhibition of PTEN expression is beneficial for nerve regeneration and functional recovery after peripheral nerve injury. Copyright © 2018 Elsevier B.V. All rights reserved.
Magnesium supplement promotes sciatic nerve regeneration and down-regulates inflammatory response.
Pan, Hung-Chuan; Sheu, Meei-Ling; Su, Hong-Lin; Chen, Ying-Ju; Chen, Chun-Jung; Yang, Dar-Yu; Chiu, Wen-Ta; Cheng, Fu-Chou
2011-06-01
Magnesium (Mg) supplements have been shown to significantly improve functional recovery in various neurological disorders. The essential benefits of Mg supplementation in peripheral nerve disorders have not been elucidated yet. The effect and mechanism of Mg supplementation on a sciatic nerve crush injury model was investigated. Sciatic nerve injury was induced in mice by crushing the left sciatic nerve. Mice were randomly divided into three groups with low-, basal- or high-Mg diets (corresponding to 10, 100 or 200% Mg of the basal diet). Neurobehavioral, electrophysiological and regeneration marker studies were conducted to explore nerve regeneration. First, a high Mg diet significantly increased plasma and nerve tissue Mg concentrations. In addition, Mg supplementation improved neurobehavioral, electrophysiological functions, enhanced regeneration marker, and reduced deposits of inflammatory cells as well as expression of inflammatory cytokines. Furthermore, reduced Schwann cell apoptosis was in line with the significant expression of bcl-2, bcl-X(L) and down-regulated expression of active caspase-3 and cytochrome C. In summary, improved neurological function recovery and enhanced nerve regeneration were found in mice with a sciatic nerve injury that were fed a high- Mg diet, and Schwann cells may have been rescued from apoptosis by the suppression of inflammatory responses.
Thapa, Lekhjung; Rana, P V S
2016-01-01
Objective. Nondiabetic obese individuals have subclinical involvement of peripheral nerves. We report the factors predicting peripheral nerve function in overweight and obese nondiabetic Nepalese individuals. Methodology. In this cross-sectional study, we included 50 adult overweight and obese nondiabetic volunteers without features of peripheral neuropathy and 50 healthy volunteers to determine the normative nerve conduction data. In cases of abnormal function, the study population was classified on the basis of the number of nerves involved, namely, "<2" or "≥2." Multivariable logistic regression analysis was carried out to predict outcomes. Results. Fasting blood glucose (FBG) was the significant predictor of motor nerve dysfunction (P = 0.039, 95% confidence interval (CI) = 1.003-1.127). Homeostatic model assessment of insulin resistance (HOMA-IR) was the significant predictor (P = 0.019, 96% CI = 1.420-49.322) of sensory nerve dysfunction. Body mass index (BMI) was the significant predictor (P = 0.034, 95% CI = 1.018-1.577) in case of ≥2 mixed nerves' involvement. Conclusion. FBG, HOMA-IR, and BMI were significant predictors of peripheral nerve dysfunction in overweight and obese Nepalese individuals.
Keilhoff, G; Fansa, H; Schneider, W; Wolf, G
1999-07-01
In vivo predegeneration of peripheral nerves is presented as a convenient and effective method to obtain activated Schwann cells and an enhanced cell yield following in vitro cultivation. The experiments conducted in rats were aimed at clinical use in gaining Schwann cell suspensions for filling artificial conduits in order to bridge peripheral nerve gaps. The rat sciatic nerve used as a model was transected distally to the spinal ganglia. Predegeneration in vivo was allowed to take place for 1, 2, 3 and 4 days and up to 1, 2 and 3 weeks. The nerve was then resected and prepared for cell cultivation. Schwann cells cultivated from the contralateral untreated nerve served as control. Immunostaining for S100, nerve growth factor receptor and the adhesion molecules N-cadherin and L1 was used to characterize the general state of the cultures. Viability was assessed by fluorescein fluorescence staining, and the proliferation index was determined by bromodeoxyuridine-DNA incorporation. The Schwann cells from predegenerated nerves revealed an increased proliferation rate compared to the control, whereas fibroblast contamination was decreased. Best results were obtained 1 week after predegeneration.
NASA Technical Reports Server (NTRS)
Ross, Muriel D.; Chee, Oliver; Black, Samuel; Cutler, Lynn
1991-01-01
Cupric ion-ferricyanide labeling methods and related ferrocyanide-stained tissues were used to locate the characterize, at the ultrastructural level, presumptive impulse initiation zones in the three types of vestibular macular nerve fibers. Large-diameter, M-type vestibular nerve fibers terminate in a calyx at the heminode, and labeling is coextensive with the base of the calyx. Intermediate, M/U-type nerve fibers have short, unmyelinated preterminal segments that sometimes bifurcate intamacularly, and small-diameter, U-type nerve fibers have long, unmyelinated preterminal axons and up to three branches. Preterminals of these nerve fibers display ultrastructural heterogeneity that is correlated with labeling patterns for sodium channels and/or associated polyanionic sites. They have a nodelike ultrastructure and label heavily from near the heminode to the base of the macula. Their intramacular branches, less organized ultrastructurally, label only slightly. Results indicate that vestibular nerve fibers have one impulse initiation zone, located near the heminode, that varies in length according to nerve fiber type. Structural heterogeneity may favor impulse conduction in the central direction, and length of the impulse initiation zone could influence nerve discharge patterns.
NASA Astrophysics Data System (ADS)
Liu, Hui; Lv, Peizhen; Zhu, Yongjia; Wu, Huayu; Zhang, Kun; Xu, Fuben; Zheng, Li; Zhao, Jinmin
2017-01-01
Salidriside (SDS), a phenylpropanoid glycoside derived from Rhodiola rosea L, has been shown to be neuroprotective in many studies, which may be promising in nerve recovery. In this study, the neuroprotective effects of SDS on engineered nerve constructed by Schwann cells (SCs) and Poly (lactic-co-glycolic acid) (PLGA) were studied in vitro. We further investigated the effect of combinational therapy of SDS and PLGA/SCs based tissue engineering on peripheral nerve regeneration based on the rat model of nerve injury by sciatic transection. The results showed that SDS dramatically enhanced the proliferation and function of SCs. The underlying mechanism may be that SDS affects SCs growth through the modulation of neurotrophic factors (BDNF, GDNF and CNTF). 12 weeks after implantation with a 12 mm gap of sciatic nerve injury, SDS-PLGA/SCs achieved satisfying outcomes of nerve regeneration, as evidenced by morphological and functional improvements upon therapy by SDS, PLGA/SCs or direct suture group assessed by sciatic function index, nerve conduction assay, HE staining and immunohistochemical analysis. Our results demonstrated the significant role of introducing SDS into neural tissue engineering to promote nerve regeneration.
Rousseau, Antoine; Cauquil, Cecile; Dupas, Benedicte; Labbé, Antoine; Baudouin, Christophe; Barreau, Emmanuel; Théaudin, Marie; Lacroix, Catherine; Guiochon-Mantel, Anne; Benmalek, Anouar; Labetoulle, Marc; Adams, David
2016-09-01
Small fiber neuropathy (SFN) is an important feature of transthyretin familial amyloid polyneuropathy (TTR-FAP). A practical and objective method for the clinical evaluation of SFN is needed to improve the management of this disease. In vivo confocal microscopy (IVCM) of the corneal nerves, a rapid noninvasive technique, may be used as a surrogate marker of SFN. To determine the correlation of SFN with IVCM in patients with TTR-FAP. A prospective, single-center, cross-sectional controlled study was conducted at the French National Reference Center for TTR-FAP from June 1, 2013, to June 30, 2014. Fifteen patients with TTR-FAP underwent a complete neurologic examination, including Neuropathy Impairment Score of the Lower Limbs, hand grip strength, and evaluation of vegetative dysfunction, as well as electrophysiologic studies (nerve conduction and electrochemical skin conductance) and intraepidermal nerve fiber density quantification. Patients and 15 controls (matched for age and sex) underwent ophthalmologic assessments, including corneal esthesiometry and IVCM. Correlation of corneal nerve fiber length (CNFL) with the severity of SFN. Of the 15 patients enrolled in the study, 6 were women (40%); mean (SD) age was 54.4 [13.7] years. The CNFL was shorter in the patients than in controls (13.08 vs 17.57 mm/mm2; difference of 4.49 [95% CI, 0.72 to 8.27]; P = .02). The patients' CNFL correlated with the severity of both autonomic neuropathy assessed by the Compound Autonomic Dysfunction Test (rs = 0.66 [95% CI, 0.22 to 0.87]; P = .008) or electrochemical skin conductance (rs = 0.80 [95% CI, 0.50 to 0.93]; P < .001) and sensorimotor neuropathy assessed using the Neuropathy Impairment Score of the Lower Limbs (rs = -0.58 [95% CI, -0.84 to -0.11]; P = .02). Patients with altered sensory nerve action potentials and intraepidermal nerve fiber density had a shorter CNFL (P = .04 and P = .02, respectively). The CNFL could be measured in all patients compared with sensory nerve action potentials (11 patients [73%; 95% CI, 44% to 92%]; P < .001) and intraepidermal nerve fiber density (4 patients [27%; 95% CI, 8% to 55%]; P < .001). In these 15 patients with TTR-FAP, IVCM measurement permitted rapid, noninvasive evaluation of small-fiber alterations in patients and could be used to assess SFN in this setting. The CNFL could be measured in all patients, thus avoiding the floor effect seen with other neuropathy measures. Longitudinal studies with more cases evaluated are needed to define the place of IVCM in monitoring patients with TTR-FAP.
NASA Astrophysics Data System (ADS)
Demkin, V. P.; Shchetinin, P. P.; Melnichuk, S. V.; Kingma, H.; Van de Berg, R.; Pleshkov, M. O.; Starkov, D. N.
2018-03-01
An electric model of current transmission through tissues of the vestibular labyrinth of a patient is suggested. To stimulate directly the vestibular nerve in surgical operation, terminations of the electrodes are implanted through the bone tissue of the labyrinth into the perilymph in the vicinity of the vestibular nerve. The biological tissue of the vestibular labyrinth surrounding the electrodes and having heterogeneous composition possesses conductive and dielectric properties. Thus, when a current pulse from the vestibular implant is applied to one of the electrodes, conductive disturbance currents may arise between the electrodes and the vestibular nerves that can significantly deteriorate the direct signal quality. To study such signals and to compensate for the conductive disturbance currents, an equivalent electric circuit with actual electric impedance properties of tissues of the vestibular system is suggested, and the time parameters of the conductive disturbance current transmission are calculated. It is demonstrated that these parameters can reach large values. The suggested electric model and the results of calculations can be used for perfection of the vestibular implant.
Gupta, Anita; Huettner, Daniel P; Dukewich, Matthew
2017-03-01
Patients suffering from osteoarthritis of the knee and patients post total knee arthroplasty often develop refractory, disabling chronic knee pain. Radiofrequency ablation, including conventional, pulsed, and cooled, has recently become more accepted as an interventional technique to manage chronic knee pain in patients who have failed conservative treatment or who are not suitable candidates for surgical treatment. This systematic review aimed to analyze published studies on radiofrequency ablation to provide an overview of the current knowledge regarding variations in procedures, nerve targets, adverse events, and temporal extent of clinical benefit. A systematic review of published studies investigating conventional, pulsed, or cooled radiofrequency ablation in the setting of chronic knee pain. Medline, Google Scholar, and the Cochrane Central Register of Controlled Trials (CENTRAL) databases were reviewed for studies on radiofrequency ablation for patients with chronic knee pain through July 29, 2016. From the studies, the procedural details, outcomes after treatment, follow-up points, and complications were compiled and analyzed in this literature review. Included studies were analyzed for clinical relevance and strength of evidence was graded using either the NHLBI Quality assessment of controlled intervention studies or the NHLBI quality assessment for before-after (pre-post) studies with no control group. Seventeen total publications were identified in the search, including articles investigating conventional, pulsed, or cooled radiofrequency ablation. These studies primarily targeted either the genicular nerves or used an intraarticular approach. Of the studies, 5 were small-sized randomized controlled trials, although one involved diathermy radiofrequency ablation. There were 8 retrospective or prospective case series and 4 case reports. Utilizing the strength of evidence grading, there is a low level of certainty to suggest a superior benefit between targeting the genicular nerve, an intraarticular approach, or targeting the larger nerves such as femoral and tibial nerves. Utilizing the strength of evidence grading, there is a low level of certainty in supporting the superiority of any specific RFA procedure modality. The majority of the studies report positive patient outcomes, but the inconsistent procedural methodology, inconsistent patient assessment measures, and small study sizes limit the applicability of any specific study to clinical practice. While the wide search strategy included a variety of articles, broad conclusions and pooled data could not be obtained based on the studies analyzed. Overall, the studies showed promising results for the treatment of severe chronic knee pain by radiofrequency ablation at up to one year with minimal complications. Numerous studies, however, yielded concerns about procedural protocols, study quality, and patient follow-up. Radiofrequency ablation can offer substantial clinical and functional benefit to patients with chronic knee pain due to osteoarthritis or post total knee arthroplasty.Key words: Radiofrequency ablation, knee osteoarthritis, knee pain, genicular nerve, total knee arthroplasty (TKA), cooled radiofrequency ablation, pulsed radiofrequency ablation.
Anderson, Matthew; Shelke, Namdev B.; Manoukian, Ohan S.; Yu, Xiaojun; McCullough, Louise D.; Kumbar, Sangamesh G.
2017-01-01
Treatment of large peripheral nerve damages ranges from the use of an autologous nerve graft to a synthetic nerve growth conduit. Biological grafts, in spite of many merits, show several limitations in terms of availability and donor site morbidity, and outcomes are suboptimal due to fascicle mismatch, scarring, and fibrosis. Tissue engineered nerve graft substitutes utilize polymeric conduits in conjunction with cues both chemical and physical, cells alone and or in combination. The chemical and physical cues delivered through polymeric conduits play an important role and drive tissue regeneration. Electrical stimulation (ES) has been applied toward the repair and regeneration of various tissues such as muscle, tendon, nerve, and articular tissue both in laboratory and clinical settings. The underlying mechanisms that regulate cellular activities such as cell adhesion, proliferation, cell migration, protein production, and tissue regeneration following ES is not fully understood. Polymeric constructs that can carry the electrical stimulation along the length of the scaffold have been developed and characterized for possible nerve regeneration applications. We discuss the use of electrically conductive polymers and associated cell interaction, biocompatibility, tissue regeneration, and recent basic research for nerve regeneration. In conclusion, a multifunctional combinatorial device comprised of biomaterial, structural, functional, cellular, and molecular aspects may be the best way forward for effective peripheral nerve regeneration. PMID:27278739
Shkarubo, Alexey Nikolaevich; Chernov, Ilia Valerievich; Ogurtsova, Anna Anatolievna; Moshchev, Dmitry Aleksandrovich; Lubnin, Andrew Jurievich; Andreev, Dmitry Nicolaevich; Koval, Konstantin Vladimirovich
2017-02-01
Intraoperative identification of cranial nerves is crucial for safe surgery of skull base tumors. Currently, only a small number of published papers describe the technique of trigger electromyography (t-EMG) in endoscopic endonasal removal of such tumors. To assess the effectiveness of t-EMG in preventing intraoperative cranial nerve damage in endoscopic endonasal surgery of skull base tumors. Nine patients were operated on using the endoscopic endonasal approach within a 1-year period. The tumors included large skull base chordomas and trigeminal neurinomas localized in the cavernous sinus. During the surgical process, cranial nerve identification was carried out using monopolar and bipolar t-EMG methods. Assessment of cranial nerve functional activity was conducted both before and after tumor removal. We mapped 17 nerves in 9 patients. Third, fifth, and sixth cranial nerves were identified intraoperatively. There were no cases of postoperative functional impairment of the mapped cranial nerves. In one case we were unable to get an intraoperative response from the fourth cranial nerve and observed its postoperative transient plegia (the function was normal before surgery). t-EMG allows surgeons to control the safety of cranial nerves both during and after skull base tumor removal. Copyright © 2016 Elsevier Inc. All rights reserved.
Omi, Maiko; Hata, Masaki; Nakamura, Nobuhisa; Miyabe, Megumi; Kobayashi, Yasuko; Kamiya, Hideki; Nakamura, Jiro; Ozawa, Shogo; Tanaka, Yoshinobu; Takebe, Jun; Matsubara, Tatsuaki; Naruse, Keiko
2016-07-01
Dental pulp stem cells (DPSCs) are thought to be an attractive candidate for cell therapy. We recently reported that the transplantation of DPSCs increased nerve conduction velocity and nerve blood flow in diabetic rats. In the present study, we investigated the immunomodulatory effects of DPSC transplantation on diabetic peripheral nerves. DPSCs were isolated from the dental pulp of Sprague-Dawley rats and expanded in culture. Eight weeks after the streptozotocin injection, DPSCs were transplanted into the unilateral hindlimb skeletal muscles. Four weeks after DPSC transplantation, neurophysiological measurements, inflammatory gene expressions and the number of CD68-positive cells in sciatic nerves were assessed. To confirm the immunomodulatory effects of DPSCs, the effects of DPSC-conditioned media on lipopolysaccharide-stimulated murine macrophage RAW264.7 cells were investigated. Diabetic rats showed significant delays in sciatic nerve conduction velocities and decreased sciatic nerve blood flow, all of which were ameliorated by DPSC transplantation. The number of CD68-positive monocytes/macrophages and the gene expressions of M1 macrophage-expressed cytokines, tumor necrosis factor-α and interleukin-1β, were increased in the sciatic nerves of the diabetic rats. DPSC transplantation significantly decreased monocytes/macrophages and tumor necrosis factor-α messenger ribonucleic acid expression, and increased the gene expression of the M2 macrophage marker, CD206, in the sciatic nerves of the diabetic rats. The in vitro study showed that DPSC-conditioned media significantly increased the gene expressions of interleukin-10 and CD206 in lipopolysaccharide-stimulated RAW264.7 cells. These results suggest that DPSC transplantation promoted macrophages polarization towards anti-inflammatory M2 phenotypes, which might be one of the therapeutic mechanisms for diabetic polyneuropathy. © 2015 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.
Garcia-Perez, E; Schönberger, T; Sumalla, M; Stierstorfer, B; Solà, R; Doods, H; Serra, J; Gorodetskaya, N
2018-04-20
Peripheral neuropathy is a common complication in type 2 diabetes mellitus (T2DM). The most common presentation is in the form of a distal axonal sensory-motor polyneuropathy that involves large and small nerve fibres in variable proportion. Zucker Diabetic Fatty (ZDF), Zucker Lean (ZL) and Wistar Han (WH) rats were used to assess the behavioural, morphological and electrophysiological effects that T2DM have on peripheral large and small nerve fibres of 6- to 40-week-old rats. ZDF rats presented mechanical hypersensitivity that initially worsened in parallel to the progression of diabetes and eventually reverted at later stages of the disease. The reversal from hypersensitivity to hyposensitivity paralleled a reduction in the number of intraepithelial skin nerve terminals and in the nerve fibre lengths. However, no increased levels of degeneration of dorsal root ganglion neurons were observed. Nerve conduction studies showed a reduction in sensory and motor nerve conduction velocity (CV) in hyperglycaemic ZDF rats. Microneurography showed significant alterations in several parameters of activity-dependent slowing (ADS) of mechano-insensitive C-nociceptors in ZDF rats. Surprisingly, some of these changes were also observed in ZL rats. Moreover, we found spontaneous activity in all three strains implying that C-nociceptors become hyperexcitable and spontaneously active not only in ageing hyperglycaemic ZDF rats but also in age-matched and apparently normoglycaemic ZL and WH rats fed with the same diet. ZDF rats presented a diabetic neuropathy involving large and small nerve fibres; additionally, ZL and WH rats also showed early small abnormalities in C-fibres, clearly detected by microneurography SIGNIFICANCE: This study provides a functional description of large and small nerve fibre function in a diabetic model that recapitulates many of the findings observed in patients suffering from type 2 diabetes mellitus. © 2018 European Pain Federation - EFIC®.
Axillary nerve injury associated with sports.
Lee, Sangkook; Saetia, Kriangsak; Saha, Suparna; Kline, David G; Kim, Daniel H
2011-11-01
The aim of this retrospective study was to present and investigate axillary nerve injuries associated with sports. This study retrospectively reviewed 26 axillary nerve injuries associated with sports between the years 1985 and 2010. Preoperative status of the axillary nerve was evaluated by using the Louisiana State University Health Science Center (LSUHSC) grading system published by the senior authors. Intraoperative nerve action potential recordings were performed to check nerve conduction and assess the possibility of resection. Neurolysis, suture, and nerve grafts were used for the surgical repair of the injured nerves. In 9 patients with partial loss of function and 3 with complete loss, neurolysis based on nerve action potential recordings was the primary treatment. Two patients with complete loss of function were treated with resection and suturing and 12 with resection and nerve grafting. The minimum follow-up period was 16 months (mean 20 months). The injuries were associated with the following sports: skiing (12 cases), football (5), rugby (2), baseball (2), ice hockey (2), soccer (1), weightlifting (1), and wrestling (1). Functional recovery was excellent. Neurolysis was performed in 9 cases, resulting in an average functional recovery of LSUHSC Grade 4.2. Recovery with graft repairs averaged LSUHSC Grade 3 or better in 11 of 12 cases Surgical repair can restore useful deltoid function in patients with sports-associated axillary nerve injuries, even in cases of severe stretch-contusion injury.
Kerasnoudis, A; Pitarokoili, K; Behrendt, V; Gold, R; Yoon, M-S
2015-01-01
We present the nerve ultrasound findings in chronic inflammatory demyelinating polyneuropathy (CIDP) and examine their correlation with electrophysiology and functional disability. A total of 75 healthy controls and 48 CIDP patients underwent clinical, sonographic and electrophysiological evaluation a mean of 3.9 years(SD+/-2.7) after disease onset. Nerve ultrasound revealed statistically significant higher cross-sectional area (CSA) values of the median (P<.0001), ulnar (P<.0001), radial (P<.0001), tibial (P<.0001), fibular nerve(P<.0001) in most of the anatomic sites and brachial plexus (supraclavicular, P<.0001;interscalene space, P = .0118),when compared to controls. The electroneurography documented signs of permanent axonal loss in the majority of peripheral nerves. A correlation between sonographic and electrophysiological findings was found only between the motor conduction velocity and CSA of the tibial nerve at the ankle (r = -.451, P = .007). Neither nerve sonography nor electrophysiology correlated with functional disability. The CSA of the median nerve in carpal tunnel and the ulnar nerve in Guyon's canal correlated with disease duration (P = .036, P = .027 respectively). CIDP seems to show inhomogenous CSA enlargement in brachial plexus and peripheral nerves, with weak correlation to electrophysiological findings. Neither nerve sonography nor electrophysiology correlated with functional disability in CIDP patients. Multicenter, prospective studies are required to proof the applicability and diagnostic values of these findings. Copyright © 2014 by the American Society of Neuroimaging.
α-Synuclein pathology in the cranial and spinal nerves in Lewy body disease.
Nakamura, Keiko; Mori, Fumiaki; Tanji, Kunikazu; Miki, Yasuo; Toyoshima, Yasuko; Kakita, Akiyoshi; Takahashi, Hitoshi; Yamada, Masahito; Wakabayashi, Koichi
2016-06-01
Accumulation of phosphorylated α-synuclein in neurons and glial cells is a histological hallmark of Lewy body disease (LBD) and multiple system atrophy (MSA). Recently, filamentous aggregations of phosphorylated α-synuclein have been reported in the cytoplasm of Schwann cells, but not in axons, in the peripheral nervous system in MSA, mainly in the cranial and spinal nerve roots. Here we conducted an immunohistochemical investigation of the cranial and spinal nerves and dorsal root ganglia of patients with LBD. Lewy axons were found in the oculomotor, trigeminal and glossopharyngeal-vagus nerves, but not in the hypoglossal nerve. The glossopharyngeal-vagus nerves were most frequently affected, with involvement in all of 20 subjects. In the spinal nerve roots, Lewy axons were found in all of the cases examined. Lewy axons in the anterior nerves were more frequent and numerous in the thoracic and sacral segments than in the cervical and lumbar segments. On the other hand, axonal lesions in the posterior spinal nerve roots appeared to increase along a cervical-to-sacral gradient. Although Schwann cell cytoplasmic inclusions were found in the spinal nerves, they were only minimal. In the dorsal root ganglia, axonal lesions were seldom evident. These findings indicate that α-synuclein pathology in the peripheral nerves is axonal-predominant in LBD, whereas it is restricted to glial cells in MSA. © 2015 Japanese Society of Neuropathology.
Outcomes from two forms of training for first-responder competency in cholinergic crisis management.
Andreatta, Pamela; Klotz, Jessica J; Madsen, James M; Hurst, Charles G; Talbot, Thomas B
2015-04-01
Military and civilian first responders must be able to recognize and effectively manage mass disaster casualties. Clinical management of injuries resulting from nerve agents provides different challenges for first responders than those of conventional weapons. We evaluated the impact of a mixed-methods training program on competency acquisition in cholinergic crisis clinical management using multimedia with either live animal or patient actor examples, and hands-on practice using SimMan3G mannequin simulators. A purposively selected sample of 204 civilian and military first responders who had not previously completed nerve agent training were assessed pre- and post-training for knowledge, performance, self-efficacy, and affective state. We conducted analysis of variance with repeated measures; statistical significance p < 0.05. Both groups had significant performance improvement across all assessment dimensions: knowledge > 20%, performance > 50%, self-efficacy > 34%, and affective state > 15%. There were no significant differences between the live animal and patient actor groups. These findings could aid in the specification of training for first-responder personnel in military and civilian service. Although less comprehensive than U.S. Army Medical Research Institute of Chemical Defense courses, the training outcomes associated with this easily distributed program demonstrate its value in increasing the competency of first responders in recognizing and managing a mass casualty cholinergic event. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.
Motor Nerve Conduction Velocity In Postmenopausal Women with Peripheral Neuropathy.
Singh, Akanksha; Asif, Naiyer; Singh, Paras Nath; Hossain, Mohd Mobarak
2016-12-01
The post-menopausal phase is characterized by a decline in the serum oestrogen and progesterone levels. This phase is also associated with higher incidence of peripheral neuropathy. To explore the relationship between the peripheral motor nerve status and serum oestrogen and progesterone levels through assessment of Motor Nerve Conduction Velocity (MNCV) in post-menopausal women with peripheral neuropathy. This cross-sectional study was conducted at Jawaharlal Nehru Medical College during 2011-2013. The study included 30 post-menopausal women with peripheral neuropathy (age: 51.4±7.9) and 30 post-menopausal women without peripheral neuropathy (control) (age: 52.5±4.9). They were compared for MNCV in median, ulnar and common peroneal nerves and serum levels of oestrogen and progesterone estimated through enzyme immunoassays. To study the relationship between hormone levels and MNCV, a stepwise linear regression analysis was done. The post-menopausal women with peripheral neuropathy had significantly lower MNCV and serum oestrogen and progesterone levels as compared to control subjects. Stepwise linear regression analysis showed oestrogen with main effect on MNCV. The findings of the present study suggest that while the post-menopausal age group is at a greater risk of peripheral neuropathy, it is the decline in the serum estrogen levels which is critical in the development of peripheral neuropathy.
Kiew, K.K.; Wan Mohamad, W.B.; Ridzuan, A.; Mafauzy, M.
2002-01-01
Thirty patients with diabetic polyneuropathy were recruited from the diabetic clinic in Hospital Universiti Sains Malaysia from 1996 to 1998. They were randomly assigned either sulbutiamine (Arcalion®) (15 patients) or no treatment (control group; 15 patients). Glycaemic control was assessed by blood glucose and HbA1. Severity of neuropathy was assessed by symptom and sign score, and electrophysiological parameters (nerve conduction velocity and compound muscle action potential) at entry to the study and after 6 weeks. There were improvements in the electrophysiological parameters in the treatment group when compared to the controls with significant improvement in the median nerve conduction velocity (p<0.001), median compound muscle action potential (p<0.001), peroneal nerve conduction velocity (p<0.001), and peroneal compound muscle action potential (p<0.001). No significant improvement in symptom and sign scores were noted between the groups but a significant improvement compared to base line was noted for the sulbutiamine treated group. (p< 0.05). The glycaemic control in both groups was not significantly different at base line and was stable throughout the study. Sulbutiamine objectively improved peripheral nerve function in diabetic polyneuropathy although the symptom score did not improve, possibly due to the short duration of the study. PMID:22969314
Kiew, K K; Wan Mohamad, W B; Ridzuan, A; Mafauzy, M
2002-01-01
Thirty patients with diabetic polyneuropathy were recruited from the diabetic clinic in Hospital Universiti Sains Malaysia from 1996 to 1998. They were randomly assigned either sulbutiamine (Arcalion(®)) (15 patients) or no treatment (control group; 15 patients). Glycaemic control was assessed by blood glucose and HbA1. Severity of neuropathy was assessed by symptom and sign score, and electrophysiological parameters (nerve conduction velocity and compound muscle action potential) at entry to the study and after 6 weeks. There were improvements in the electrophysiological parameters in the treatment group when compared to the controls with significant improvement in the median nerve conduction velocity (p<0.001), median compound muscle action potential (p<0.001), peroneal nerve conduction velocity (p<0.001), and peroneal compound muscle action potential (p<0.001). No significant improvement in symptom and sign scores were noted between the groups but a significant improvement compared to base line was noted for the sulbutiamine treated group. (p< 0.05). The glycaemic control in both groups was not significantly different at base line and was stable throughout the study. Sulbutiamine objectively improved peripheral nerve function in diabetic polyneuropathy although the symptom score did not improve, possibly due to the short duration of the study.
Xing, Yian; Chen, Lianhua; Li, Shitong
2013-11-01
Muscles innervated by the facial nerve show different sensitivities to muscle relaxants than muscles innervated by somatic nerves, especially in the presence of facial nerve injury. We compared the evoked electromyography (EEMG) response of orbicularis oris and gastrocnemius in with and without a non-depolarizing muscle relaxant in a rabbit model of graded facial nerve injury. Differences in EEMG response and inhibition by rocuronium were measured in the orbicularis oris and gastrocnemius muscles 7 to 42 d after different levels of facial nerve crush injuries in adult rabbits. Baseline EEMG of orbicularis oris was significantly smaller than those of the gastrocnemius. Gastrocnemius was more sensitive to rocuronium than the facial muscles (P < 0.05). Baseline EEMG and EEMG amplitude of orbicularis oris in the presence of rocuronium was negatively correlated with the magnitude of facial nerve injury but the sensitivity to rocuronium was not. No significant difference was found in the onset time and the recovery time of rocuronium among gastrocnemius and normal or damaged facial muscles. Muscles innervated by somatic nerves are more sensitive to rocuronium than those innervated by the facial nerve, but while facial nerve injury reduced EEMG responses, the sensitivity to rocuronium is not altered. Partial neuromuscular blockade may be a suitable technique for conducting anesthesia and surgery safely when EEMG monitoring is needed to preserve and protect the facial nerve. Additional caution should be used if there is a risk of preexisting facial nerve injury. Copyright © 2013 Elsevier Inc. All rights reserved.
Pitarokoili, Kalliopi; Kronlage, Moritz; Bäumer, Philip; Schwarz, Daniel; Gold, Ralf; Bendszus, Martin; Yoon, Min-Suk
2018-01-01
Background: We present a clinical, electrophysiological, sonographical and magnetic resonance neurography (MRN) study examining the complementary role of two neuroimaging methods of the peripheral nervous system for patients with chronic inflammatory demyelinating polyneuropathy (CIDP). Furthermore, we explore the significance of cross-sectional area (CSA) increase through correlations with MRN markers of nerve integrity. Methods: A total of 108 nerve segments on the median, ulnar, radial, tibial and fibular nerve, as well as the lumbar and cervical plexus of 18 CIDP patients were examined with high-resonance nerve ultrasound (HRUS) and MRN additionally to the nerve conduction studies. Results: We observed a fair degree of correlation of the CSA values for all nerves/nerve segments between the two methods, with a low random error in Bland–Altman analysis (bias = HRUS-CSA − MRN-CSA, −0.61 to −3.26 mm). CSA in HRUS correlated with the nerve T2-weighted (nT2) signal increase as well as with diffusion tensor imaging parameters such as fractional anisotropy, a marker of microstructural integrity. HRUS-CSA of the interscalene brachial plexus correlated significantly with the MRN-CSA and nT2 signal of the L5 and S1 roots of the lumbar plexus. Conclusions: HRUS allows for reliable CSA imaging of all peripheral nerves and the cervical plexus, and CSA correlates with markers of nerve integrity. Imaging of proximal segments as well as the estimation of nerve integrity require MRN as a complementary method. PMID:29552093
Youssef, Tamer; Youssef, Mohamed; Thabet, Waleed; Lotfy, Ahmed; Shaat, Reham; Abd-Elrazek, Eman; Farid, Mohamed
2015-10-01
The objective of this study was to evaluate the efficacy of transcutaneous electrical posterior tibial nerve stimulation in treatment of patients with chronic anal fissure and to compare it with the conventional lateral internal sphincterotomy. Consecutive patients with chronic anal fissure were randomly allocated into two treatment groups: transcutaneous electrical posterior tibial nerve stimulation group and lateral internal sphincterotomy group. The primary outcome measures were number of patients with clinical improvement and healed fissure. Secondary outcome measures were complications, VAS pain scores, Wexner's constipation and Peascatori anal incontinence scores, anorectal manometry, and quality of life index. Seventy-three patients were randomized into two groups of 36 patients who were subjected to transcutaneous electrical nerve stimulation and 37 patients who underwent lateral internal sphincterotomy. All (100%) patients in lateral internal sphincterotomy group had clinical improvement at one month following the procedure in contrast to 27 (75%) patients in transcutaneous electrical nerve stimulation group. Recurrence of anal fissure after one year was reported in one (2.7%) and 11 (40.7%) patients in lateral internal sphincterotomy and transcutaneous electrical nerve stimulation groups respectively. Resting anal pressure and functional anal canal length were significantly reduced after lateral internal sphincterotomy. Transcutaneous electrical posterior tibial nerve stimulation for treatment of chronic anal fissure is a novel, non-invasive procedure and has no complications. However, given the higher rate of clinical improvement and fissure healing and the lower rate of fissure recurrence, lateral internal sphincterotomy remains the gold standard for treating chronic anal fissure. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.
Puonti, Helena K; Jääskeläinen, Satu K; Hallikainen, Helena K; Partanen, Taina A
2012-09-01
Classic abdominoplasty for a transverse rectus abdominis musculocutaneous (TRAM) flap breast reconstruction impairs abdominal somatosensory function at the donor site. The aim of this study was to investigate whether the type of surgical procedure has an effect on somatosensory alterations of abdominal skin after TRAM flap breast reconstruction. Sixty patients (mean ± SD age, 50 ± 6.0 years) who underwent microvascular TRAM flap breast reconstruction and 20 healthy subjects (control group; mean age, 46 ± 6.7 years) participated in the study. Twenty patients had bilateral-nerve anastomosis, 20 had single-nerve anastomosis, and 20 underwent no nerve dissection for the TRAM flap. Clinical sensory examination and tactile and thermal quantitative sensory testing were performed and a patient questionnaire was administered at a mean of 2 to 4.5 years after surgery. All surgical techniques produced significant sensory impairment below the umbilicus, but there were no significant differences in total sensibility scores between the groups with single-nerve (mean sensibility score, 21.98 ± 2.7) and double-nerve (mean sensibility score, 20.71 ± 3.6) anastomosis of the TRAM flap. The best sensibility scores were found in the group with single-nerve dissection. Fifteen percent of patients complained of mild pain, and 13 percent felt occasional tactile hyperesthesia in their abdominal skin, mostly around the umbilicus and scars. In this study, unilateral or bilateral nerve dissection when preparing and lifting a TRAM flap did not seem to increase sensory alterations or postoperative pain in the abdominal donor site after breast reconstruction surgery. Cautious microneurovascular dissection techniques may even improve sensory recovery of the abdominal skin after TRAM flap breast reconstruction surgery.
Sakai, Takayuki; Doi, Kunio; Yoneyama, Masami; Watanabe, Atsuya; Miyati, Tosiaki; Yanagawa, Noriyuki
2018-06-01
Diffusion tensor imaging (DTI) based on a single-shot echo planer imaging (EPI-DTI) is an established method that has been used for evaluation of lumbar nerve disorders in previous studies, but EPI-DTI has problems such as a long acquisition time, due to a lot of axial slices, and geometric distortion. To solve these problems, we attempted to apply DTI based on a single-shot turbo spin echo (TSE-DTI) with direct coronal acquisition. Our purpose in this study was to investigate whether TSE-DTI may be more useful for evaluation of lumbar nerve disorders than EPI-DTI. First, lumbar nerve roots of five healthy volunteers were evaluated for optimization of imaging parameters with TSE-DTI including b-values and the number of motion proving gradient (MPG) directions. Subsequently, optimized TSE-DTI was quantitatively compared with conventional EPI-DTI by using fractional anisotropy (FA) values and visual scores in subjective visual evaluation of tractography. Lumbar nerve roots of six patients, who had unilateral neurologic symptoms in one leg, were evaluated by the optimized TSE-DTI. TSE-DTI with b-value of 400 s/mm 2 and 32 diffusion-directions could reduce the image distortion compared with EPI-DTI, and showed that the average FA values on the symptomatic side for six patients were significantly lower than those on the non-symptomatic side (P < 0.05). Tractography with TSE-DTI might show damaged areas of lumbar nerve roots without severe image distortion. TSE-DTI might improve the reproducibility in measurements of FA values for quantification of a nerve disorder, and would become a useful tool for diagnosis of low back pain. Copyright © 2018 Elsevier Inc. All rights reserved.
2014-01-01
Background Hip fractures are very painful leading to lengthy hospital stays. Conventional methods of treating pain are limited. Non-steroidal anti-inflammatories are relatively contraindicated and opioids have significant side effects.Regional anaesthesia holds promise but results from these techniques are inconsistent. Trials to date have been inconclusive with regard to which blocks to use and for how long. Interpatient variability remains a problem. Methods/Design This is a single centre study conducted at Queen’s Medical Centre, Nottingham; a large regional trauma centre in England. It is a pragmatic, parallel arm, randomized controlled trial. Sample size will be 150 participants (75 in each group). Randomization will be web-based, using computer generated concealed tables (service provided by Nottingham University Clinical Trials Unit). There is no blinding. Intervention will be a femoral nerve block (0.5 mls/kg 0.25% levo-bupivacaine) followed by ropivacaine (0.2% 5 ml/hr−1) infused via a femoral nerve catheter until 48 hours post-surgery. The control group will receive standard care. Participants will be aged over 70 years, cognitively intact (abbreviated mental score of seven or more), able to provide informed consent, and admitted directly through the Emergency Department from their place of residence. Primary outcomes will be cumulative ambulation score (from day 1 to 3 postoperatively) and cumulative dynamic pain scores (day 1 to 3 postoperatively). Secondary outcomes will be cumulative dynamic pain score preoperatively, cumulative side effects, cumulative calorific and protein intake, EUROQOL EQ-5D score, length of stay, and rehabilitation outcome (measured by mobility score). Discussion Many studies have shown the effectiveness of regional blockade in neck of femur fractures, but the techniques used have varied. This study aims to identify whether early and continuous femoral nerve block can be effective in relieving pain and enhancing mobilization.Trial registration. Trial registration The trial is registered with the European clinical trials database Eudract ref: 2010-023871-25. (17/02/2011). ISRCTN: ISRCTN92946117. Registered 26 October 2012. PMID:24885267
Wang, Shuping; Guan, Shui; Zhu, Zhibo; Li, Wenfang; Liu, Tianqing; Ma, Xuehu
2017-02-01
Conducting polymer, as a "smart" biomaterial, has been increasingly used to construct tissue engineered scaffold for nerve tissue regeneration. In this study, a novel porous conductive scaffold was prepared by incorporating conductive hyaluronic acid (HA) doped-poly(3,4-ethylenedioxythiophene) (PEDOT-HA) nanoparticles into a chitosan/gelatin (Cs/Gel) matrix. The physicochemical characteristics of Cs/Gel scaffold with 0-10wt% PEDOT-HA were analyzed and the results indicated that the incorporation of PEDOT-HA into scaffold increased the electrical and mechanical properties while decreasing the porosity and water absorption. Moreover, in vitro biodegradation of scaffold displayed a declining trend with the PEDOT-HA content increased. About the biocompatibility of conductive scaffold, neuron-like rat phaeochromocytoma (PC12) cells were cultured in scaffold to evaluate cell adhesion and growth. 8% PEDOT-HA/Cs/Gel scaffold had a higher cell adhesive efficiency and cell viability than the other conductive scaffolds. Furthermore, cells in the scaffold with 8wt% PEDOT-HA expressed higher synapse growth gene of GAP43 and SYP compared with Cs/Gel control group. These results suggest that 8%PEDOT-HA/Cs/Gel scaffold is an attractive cell culture conductive substrate which could support cell adhesion, survival, proliferation, and synapse growth for the application in nerve tissue regeneration. Copyright © 2016 Elsevier B.V. All rights reserved.
The design of and chronic tissue response to a composite nerve electrode with patterned stiffness.
Freeberg, M J; Stone, M A; Triolo, R J; Tyler, D J
2017-06-01
As neural interfaces demonstrate success in chronic applications, a novel class of reshaping electrodes with patterned regions of stiffness will enable application to a widening range of anatomical locations. Patterning stiff regions and flexible regions of the electrode enables nerve reshaping while accommodating anatomical constraints of various implant locations ranging from peripheral nerves to spinal and autonomic plexi. Introduced is a new composite electrode enabling patterning of regions of various electrode mechanical properties. The initial demonstration of the composite's capability is the composite flat interface nerve electrode (C-FINE). The C-FINE is constructed from a sandwich of patterned PEEK within layers of pliable silicone. The shape of the PEEK provides a desired pattern of stiffness: stiff across the width of the nerve to reshape the nerve, but flexible along its length to allow for bending with the nerve. This is particularly important in anatomical locations near joints or organs, and in constrained compartments. We tested pressure and volume design constraints in vitro to verify that the C-FINE can attain a safe cuff-to-nerve ratio (CNR) without impeding intraneural blood flow. We measured nerve function as well as nerve and axonal morphology following 3 month implantation of the C-FINE without wires on feline peripheral nerves in anatomically constrained areas near mobile joints and major blood vessels in both the hind and fore limbs. In vitro inflation tests showed effective CNRs (1.93 ± 0.06) that exceeded the industry safety standard of 1.5 at an internal pressure of 20 mmHg. This is less than the 30 mmHg shown to induce loss of conduction or compromise blood flow. Implanted cats showed no changes in physiology or electrophysiology. Behavioral signs were normal suggesting healthy nerves. Motor nerve conduction velocity and compound motor action potential did not change significantly between implant and explant (p > 0.15 for all measures). Axonal density and myelin sheath thickness was not significantly different within the electrode compared to sections greater than 2 cm proximal to implanted cuffs (p > 0.14 for all measures). We present the design and verification of a novel nerve cuff electrode, the C-FINE. Laminar manufacturing processes allow C-FINE stiffness to be configured for specific applications. Here, the central region in the configuration tested is stiff to reshape or conform to the target nerve, while edges are highly flexible to bend along its length. The C-FINE occupies less volume than other NCEs, making it suitable for implantation in highly mobile locations near joints. Design constraints during simulated transient swelling were verified in vitro. Maintenance of nerve health in various challenging anatomical locations (sciatic and median/ulnar nerves) was verified in a chronic feline model in vivo.
The design of and chronic tissue response to a composite nerve electrode with patterned stiffness
NASA Astrophysics Data System (ADS)
Freeberg, M. J.; Stone, M. A.; Triolo, R. J.; Tyler, D. J.
2017-06-01
Objective. As neural interfaces demonstrate success in chronic applications, a novel class of reshaping electrodes with patterned regions of stiffness will enable application to a widening range of anatomical locations. Patterning stiff regions and flexible regions of the electrode enables nerve reshaping while accommodating anatomical constraints of various implant locations ranging from peripheral nerves to spinal and autonomic plexi. Approach. Introduced is a new composite electrode enabling patterning of regions of various electrode mechanical properties. The initial demonstration of the composite’s capability is the composite flat interface nerve electrode (C-FINE). The C-FINE is constructed from a sandwich of patterned PEEK within layers of pliable silicone. The shape of the PEEK provides a desired pattern of stiffness: stiff across the width of the nerve to reshape the nerve, but flexible along its length to allow for bending with the nerve. This is particularly important in anatomical locations near joints or organs, and in constrained compartments. We tested pressure and volume design constraints in vitro to verify that the C-FINE can attain a safe cuff-to-nerve ratio (CNR) without impeding intraneural blood flow. We measured nerve function as well as nerve and axonal morphology following 3 month implantation of the C-FINE without wires on feline peripheral nerves in anatomically constrained areas near mobile joints and major blood vessels in both the hind and fore limbs. Main Results. In vitro inflation tests showed effective CNRs (1.93 ± 0.06) that exceeded the industry safety standard of 1.5 at an internal pressure of 20 mmHg. This is less than the 30 mmHg shown to induce loss of conduction or compromise blood flow. Implanted cats showed no changes in physiology or electrophysiology. Behavioral signs were normal suggesting healthy nerves. Motor nerve conduction velocity and compound motor action potential did not change significantly between implant and explant (p > 0.15 for all measures). Axonal density and myelin sheath thickness was not significantly different within the electrode compared to sections greater than 2 cm proximal to implanted cuffs (p > 0.14 for all measures). Significance. We present the design and verification of a novel nerve cuff electrode, the C-FINE. Laminar manufacturing processes allow C-FINE stiffness to be configured for specific applications. Here, the central region in the configuration tested is stiff to reshape or conform to the target nerve, while edges are highly flexible to bend along its length. The C-FINE occupies less volume than other NCEs, making it suitable for implantation in highly mobile locations near joints. Design constraints during simulated transient swelling were verified in vitro. Maintenance of nerve health in various challenging anatomical locations (sciatic and median/ulnar nerves) was verified in a chronic feline model in vivo.
Barras, Florian M; Kuntzer, Thierry; Zurn, Anne D; Pasche, Philippe
2009-05-01
Facial nerve regeneration is limited in some clinical situations: in long grafts, by aged patients, and when the delay between nerve lesion and repair is prolonged. This deficient regeneration is due to the limited number of regenerating nerve fibers, their immaturity and the unresponsiveness of Schwann cells after a long period of denervation. This study proposes to apply glial cell line-derived neurotrophic factor (GDNF) on facial nerve grafts via nerve guidance channels to improve the regeneration. Two situations were evaluated: immediate and delayed grafts (repair 7 months after the lesion). Each group contained three subgroups: a) graft without channel, b) graft with a channel without neurotrophic factor; and c) graft with a GDNF-releasing channel. A functional analysis was performed with clinical observation of facial nerve function, and nerve conduction study at 6 weeks. Histological analysis was performed with the count of number of myelinated fibers within the graft, and distally to the graft. Central evaluation was assessed with Fluoro-Ruby retrograde labeling and Nissl staining. This study showed that GDNF allowed an increase in the number and the maturation of nerve fibers, as well as the number of retrogradely labeled neurons in delayed anastomoses. On the contrary, after immediate repair, the regenerated nerves in the presence of GDNF showed inferior results compared to the other groups. GDNF is a potent neurotrophic factor to improve facial nerve regeneration in grafts performed several months after the nerve lesion. However, GDNF should not be used for immediate repair, as it possibly inhibits the nerve regeneration.
Bourke, Henry E; Read, Jeremy; Kampa, Rebecca; Hearnden, Anthony; Davey, Paul A
2011-01-01
INTRODUCTION Carpal tunnel syndrome is the most common compression neuropathy affecting the upper limb. Clinical diagnosis is not always clear and electrophysiological testing can be indicated when considering a patient for decompression surgery. The downside of electrophysiological testing is cost and increased time to surgery. Newer methods of performing nerve conduction studies in clinic have become available. MATERIALS AND METHODS We investigated the use of a clinic-based, handheld, non-invasive electrophysiological device (NC-stat®) in 71 patients with suspected carpal tunnel syndrome presenting to our hand clinic in a district general hospital. We compared this to a similar cohort of 71 age-matched patients also presenting to our unit in whom formal nerve conduction studies were performed at a local neurophysiology unit. Our outcome measures were time from presentation to carpal tunnel decompression, the cost of each pathway and the practicalities of using the device in a busy hand unit. RESULTS AND CONCLUSIONS The NC-stat® proved to be a successful device when compared with referring patients out for more formal nerve conduction studies, shortening the time from presentation to surgery from 198 days to 102 days (p<0.0001). It was also cost effective with a calculated saving to the hospital of more than £70 per patient. The device is easy to use and acceptable to patients and no adverse effects were noted. PMID:21477439
NASA Astrophysics Data System (ADS)
Schulz-Ertner, Daniela
In skull base tumors associated with a low radiosensitivity for conventional radiotherapy (RT), irradiation with proton or carbon ion beams facilitates a safe and accurate application of high tumor doses due to the favorable beam localization properties of these particle beams. Cranial nerves, the brain stem and normal brain tissue can at the same time be optimally spared.
Schaumburg, Herbert H; Zotova, Elena; Cannella, Barbara; Raine, Cedric S; Arezzo, Joseph; Tar, Moses; Melman, Arnold
2007-04-01
To illustrate the ultrastructural fibre composition of the rat cavernosal nerve at serial levels, from its origin in the main pelvic ganglion to its termination in the corpus cavernosum of the distal penile shaft, and to develop a technique that permits repeated electrophysiological recording from the fibres that form the cavernosal nerve distinct from the axons of the dorsal nerve of the penis (DNP). For the light microscope and ultrastructural studies, Sprague-Dawley rats were anaesthetized and the pelvic organs and lower limbs were perfused with glutaraldehyde through the distal aorta. Tissue samples were embedded in epoxy resin and prepared for light and electron microscopy. Frozen tissue was used for the immunohistochemical studies and sections were stained with rabbit anti-nitric oxide synthetase 1 (NOS1). For the electrophysiology, anaesthetized rats were used in sterile conditions. Nerve conduction velocity for the cavernosal nerve was assessed from a point 2 mm below the main (major) pelvic ganglion after stimulating the nerve at the crus penis; multi-unit averaging techniques were used to enhance the recording of slow-conduction activity. Recordings from the DNP were obtained over the proximal shaft after stimulation at the base of the penis. Step-serial sections of the cavernosal nerve revealed numerous ganglion cells in the initial segments and gradually fewer myelinated fibres at distal levels. At the point of crural entry, the nerve contained almost exclusively unmyelinated axons. As it descended the penile shaft, the nerve separated into small fascicles containing only one to four axons at the level of the distal shaft. In the corpus cavernosum, vesicle-filled presynaptic axon preterminals were close to smooth muscle fibres, but did not seem to be in direct contact. Immunohistochemical evaluation of NOS1 activity showed intense staining of the fibres of the DNP and most of the neurones in the main pelvic ganglion. There was also scattered NOS1 activity in the nerve bundles of the corpus cavernosum. Electrophysiology identified activity in C fibres on the cavernosal nerve and in Aalpha-Adelta fibres in the DNP. These results show that it is possible to perform integrated cavernosal pressure monitoring and ultrastructural and electrophysiological studies in this model. These yielded accurate data about the erectile status of the penis, and the state of unmyelinated and myelinated fibres in the DNP and cavernosal nerves of the same animal. This study provides a useful template for future studies of experimental diabetic autonomic neuropathy.
Peripheral Neuropathy in Spinocerebellar Ataxia Type 1, 2, 3, and 6.
Linnemann, Christoph; Tezenas du Montcel, Sophie; Rakowicz, Maryla; Schmitz-Hübsch, Tanja; Szymanski, Sandra; Berciano, Jose; van de Warrenburg, Bart P; Pedersen, Karine; Depondt, Chantal; Rola, Rafal; Klockgether, Thomas; García, Antonio; Mutlu, Gurkan; Schöls, Ludger
2016-04-01
Spinocerebellar ataxias (SCAs) are characterized by autosomal dominantly inherited progressive ataxia but are clinically heterogeneous due to variable involvement of non-cerebellar parts of the nervous system. Non-cerebellar symptoms contribute significantly to the burden of SCAs, may guide the clinician to the underlying genetic subtype, and might be useful markers to monitor disease. Peripheral neuropathy is frequently observed in SCA, but subtype-specific features and subclinical manifestations have rarely been evaluated. We performed a multicenter nerve conduction study with 162 patients with genetically confirmed SCA1, SCA2, SCA3, and SCA6. The study proved peripheral nerves to be involved in the neurodegenerative process in 82 % of SCA1, 63 % of SCA2, 55 % of SCA3, and 22 % of SCA6 patients. Most patients of all subtypes revealed affection of both sensory and motor fibers. Neuropathy was most frequently of mixed type with axonal and demyelinating characteristics in all SCA subtypes. However, nerve conduction velocities of SCA1 patients were slower compared to other genotypes. SCA6 patients revealed less axonal damage than patients with other subtypes. No influence of CAG repeat length or biometric determinants on peripheral neuropathy could be identified in SCA1, SCA3, and SCA6. In SCA2, earlier onset and more severe ataxia were associated with peripheral neuropathy. We proved peripheral neuropathy to be a frequent site of the neurodegenerative process in all common SCA subtypes. Since damage to peripheral nerves is readily assessable by electrophysiological means, nerve conduction studies should be performed in a longitudinal approach to assess these parameters as potential progression markers.
Diabetes, peripheral neuropathy, and lower-extremity function.
Chiles, Nancy S; Phillips, Caroline L; Volpato, Stefano; Bandinelli, Stefania; Ferrucci, Luigi; Guralnik, Jack M; Patel, Kushang V
2014-01-01
Diabetes among older adults causes many complications, including decreased lower-extremity function and physical disability. Diabetes can cause peripheral nerve dysfunction, which might be one pathway through which diabetes leads to decreased physical function. The study aims were to determine the following: (1) whether diabetes and impaired fasting glucose are associated with objective measures of physical function in older adults, (2) which peripheral nerve function (PNF) tests are associated with diabetes, and (3) whether PNF mediates the diabetes-physical function relationship. This study included 983 participants, age 65 years and older from the InCHIANTI study. Diabetes was diagnosed by clinical guidelines. Physical performance was assessed using the Short Physical Performance Battery (SPPB), scored from 0 to 12 (higher values, better physical function) and usual walking speed (m/s). PNF was assessed via standard surface electroneurographic study of right peroneal nerve conduction velocity, vibration and touch sensitivity. Clinical cutpoints of PNF tests were used to create a neuropathy score from 0 to 5 (higher values, greater neuropathy). Multiple linear regression models were used to test associations. One hundred twenty-six (12.8%) participants had diabetes. Adjusting for age, sex, education, and other confounders, diabetic participants had decreased SPPB (β=-0.99; p<0.01), decreased walking speed (β=-0.1m/s; p<0.01), decreased nerve conduction velocity (β=-1.7m/s; p<0.01), and increased neuropathy (β=0.25; p<0.01) compared to non-diabetic participants. Adjusting for nerve conduction velocity and neuropathy score decreased the effect of diabetes on SPPB by 20%, suggesting partial mediation through decreased PNF. © 2014.
Diabetes, Peripheral Neuropathy, and Lower Extremity Function
Chiles, Nancy S.; Phillips, Caroline L.; Volpato, Stefano; Bandinelli, Stefania; Ferrucci, Luigi; Guralnik, Jack M.; Patel, Kushang V.
2014-01-01
Objective Diabetes among older adults causes many complications, including decreased lower extremity function and physical disability. Diabetes can cause peripheral nerve dysfunction, which might be one pathway through which diabetes leads to decreased physical function. The study aims were to determine: (1) whether diabetes and impaired fasting glucose are associated with objective measures of physical function in older adults, (2) which peripheral nerve function (PNF) tests are associated with diabetes, and (3) whether PNF mediates the diabetes-physical function relationship. Research Design and Methods This study included 983 participants, age 65 and older from the InCHIANTI Study. Diabetes was diagnosed by clinical guidelines. Physical performance was assessed using the Short Physical Performance Battery (SPPB), scored from 0-12 (higher values, better physical function) and usual walking speed (m/s). PNF was assessed via standard surface electroneurographic study of right peroneal nerve conduction velocity, vibration and touch sensitivity. Clinical cut-points of PNF tests were used to create a neuropathy score from 0-5 (higher values, greater neuropathy). Multiple linear regression models were used to test associations. Results and Conclusion 12.8% (n=126) of participants had diabetes. Adjusting for age, sex, education, and other confounders, diabetic participants had decreased SPPB (β= −0.99; p< 0.01), decreased walking speed (β= −0.1m/s; p< 0.01), decreased nerve conduction velocity (β= −1.7m/s; p< 0.01), and increased neuropathy (β= 0.25; p< 0.01) compared to non-diabetic participants. Adjusting for nerve conduction velocity and neuropathy score decreased the effect of diabetes on SPPB by 20%, suggesting partial mediation through decreased PNF. PMID:24120281
Symptoms, signs and nerve conduction velocities in patients with suspected carpal tunnel syndrome.
Ntani, Georgia; Palmer, Keith T; Linaker, Cathy; Harris, E Clare; Van der Star, Richard; Cooper, Cyrus; Coggon, David
2013-08-15
To inform the clinical management of patients with suspected carpal tunnel syndrome (CTS) and case definition for CTS in epidemiological research, we explored the relation of symptoms and signs to sensory nerve conduction (SNC) measurements. Patients aged 20-64 years who were referred to a neurophysiology service for investigation of suspected CTS, completed a symptom questionnaire (including hand diagrams) and physical examination (including Tinel's and Phalen's tests). Differences in SNC velocity between the little and index finger were compared according to the anatomical distribution of symptoms in the hand and findings on physical examination. Analysis was based on 1806 hands in 908 patients (response rate 73%). In hands with numbness or tingling but negative on both Tinel's and Phalen's tests, the mean difference in SNC velocities was no higher than in hands with no numbness or tingling. The largest differences in SNC velocities occurred in hands with extensive numbness or tingling in the median nerve sensory distribution and both Tinel's and Phalen's tests positive (mean 13.8, 95% confidence interval (CI) 12.6-15.0 m/s). Hand pain and thumb weakness were unrelated to SNC velocity. Our findings suggest that in the absence of other objective evidence of median nerve dysfunction, there is little value in referring patients of working age with suspected CTS for nerve conduction studies if they are negative on both Tinel's and Phalen's tests. Alternative case definitions for CTS in epidemiological research are proposed according to the extent of diagnostic information available and the relative importance of sensitivity and specificity.
Hayashi, Kazuko
2016-12-01
Recently, NuVasive NV-M5 nerve monitoring system, a new transcranial motor-evoked potential (TcMEP) monitor, has been introduced with the spread of flank-approach spinal operations such as extreme lateral interbody fusion, to prevent nerve damage. Conventional TcMEP monitors use changes in MEP wave patterns, such as amplitude and/or latency, whereas the NV-M5 nerve monitor system first measures the MEP baseline waveform from the transcranial-evoked potential then measures the electric current necessary to obtain the standard of the previous baseline wave pattern at subsequent monitoring times. The NV-M5 monitor determines nerve damage according to the increase in necessary electric current threshold. The NV-M5 monitor also uses a local electrical stimulation mode to monitor the safety of setting screws into the lumbar vertebrae. In this way, various electrical stimulations with various durations and frequencies are used, and electrical noise may result in unpredictable interference with cardiac pacemakers. We performed anesthetic management of extreme lateral interbody fusion surgery using the NV-M5 in a patient with an implanted pacemaker, during which TcMEP stimulation caused interference with the implanted pacemaker. Copyright © 2016 Elsevier Inc. All rights reserved.
Retrospective study of a TTR FAP cohort to modify NIS+7 for therapeutic trials.
Suanprasert, N; Berk, J L; Benson, M D; Dyck, P J B; Klein, C J; Gollob, J A; Bettencourt, B R; Karsten, V; Dyck, P J
2014-09-15
Protein stabilization and oligonucleotide therapies are being tested in transthyretin amyloid polyneuropathy (TTR FAP) trials. From retrospective analysis of 97 untreated TTR FAP patients, we test the adequacy of Neuropathy Impairment Score+7 tests (NIS+7) and modifications to comprehensively score impairments for use in such therapeutic trials. Our data confirms that TTR FAP usually is a sensorimotor polyneuropathy with autonomic features which usually is symmetric, length dependent, lower limb predominant and progressive. NIS+7 adequately assesses weakness and muscle stretch reflexes without ceiling effects but not sensation loss, autonomic dysfunction or nerve conduction abnormalities. Three modifications of NIS+7 are suggested: 1) use of Smart Somatotopic Quantitative Sensation Testing (S ST QSTing); 2) choice of new autonomic assessments, e.g., sudomotor testing of distributed anatomical sites; and 3) use of only compound muscle action potential amplitudes (of ulnar, peroneal and tibial nerves) and sensory nerve action potentials of ulnar and sural nerve - than the previously recommended attributes suggested for the sensitive detection of diabetic sensorimotor polyneuropathy. These modifications of NIS+7 if used in therapeutic trials should improve characterization and quantification of sensation and autonomic impairment in TTR FAP and provide better nerve conduction tests. Copyright © 2014 Elsevier B.V. All rights reserved.
Reliability of the nerve conduction monitor in repeated measures of median and ulnar nerve latencies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washington, I A
According to the Bureau of Labor Statistics, carpal tunnel syndrome (CTS), one of the most rapidly growing work-related injuries, cost American businesses up to $10 billion dollars in medical costs each year (1992). Because conservative therapy can be implemented and CTS is more reversible in it early stages, early detection will not only save industry unnecessary health care costs, but also prevent employees from experiencing debilitating pain and unnecessary surgery. In response to the growing number of cases of CTS, many companies have introduced screening tools to detect early stages of carpal tunnel syndrome. Neurotron Medical (New Jersey) has designedmore » a portable nerve conduction monitor (Nervepace S-200) which measures motor and sensory nerve latencies. The slowing of these latencies is one diagnostic indicator of carpal tunnel syndrome. In this study, we determined the reliability of the Nervepace Monitor in measure ulnar and median nerve latencies during repeated testing. The testing was performed on 28 normal subjects between the ages of 20 and 35 who had no prior symptoms of CTS. They were tested at the same time each day for three consecutive days. Nerve latencies between different ethnic groups and genders were compared. Results show that there was no significant daily variation of the median motor and lunar sensory latencies or the median sensory latencies. No significant differences of latencies was observed among ethnic groups; however, a significant difference of latencies between male and female subjects was observed (p<0.05).« less
Lipid-lowering drugs (statins) and peripheral neuropathy.
Emad, Mohammadreza; Arjmand, Hosein; Farpour, Hamid Reza; Kardeh, Bahareh
2018-03-01
Peripheral neuropathy is a disorder with often unknown causes. Some drugs, including statins, are proposed to be among the causes of peripheral neuropathy. This study aimed at evaluating this condition by electrodiagnostic study among patients who had received statins. This case-control study was conducted in Shiraz, Iran in 2015, and included 39 patients aged 35-55 who had received statins for at least 6 months, and 39 healthy matched controls. Using electrodiagnosis, the sensory and motor wave features (amplitude, latency and nerve conduction velocity) of the peripheral nerves (Median, Ulnar, Tibial, Sural, and Peroneal) were evaluated among the subjects. Data were analyzed using SPSS software and p<0.05 was considered statistically significant. Regarding the occurrence of neuropathy, there were no significant differences in any of the definitions presented for peripheral neuropathy. However, the difference was close to significance for one definition [2 abnormalities in 2 nerves (p=0.055)]. Regarding mean values of the features, significant differences were observed in two features: amplitude of the peroneal motor nerve (p=0.048) and amplitude of the sural sensory nerve (p=0.036). Since statins are widely used, awareness regarding their side-effects would lead to better treatment. Even though no significant differences were found between the groups regarding the occurrence of peripheral neuropathy, there were significant differences in amplitudes of the sural sensory response and the peroneal motor response. This indicates the involvement of peripheral nerves. Therefore, we recommend that patients and physicians should be informed about the possible symptoms of this condition.
Mumford, Helen; Troyer, John K.
2011-01-01
Poisoning by nerve agents via the percutaneous (p.c.) route is an issue because the slow absorption of agent could result in poisoning which outlasts the protection provided by conventional pharmacological therapy. The bioscavenger approach is based on the concept of binding nerve agent in the bloodstream, thus preventing nerve agent from reaching the target tissues and inhibiting acetylcholinesterase activity. One bioscavenger that has been extensively studied is human butyrylcholinesterase (huBuChE). Protexia® is a pegylated form of recombinant huBuChE. We used a guinea-pig model of p.c. nerve agent poisoning, using an implanted telemetry system to collect physiological data. Guinea-pigs were poisoned with the nerve agent VX (0.74 mg/kg) (~2.5×LD50). Two hours following VX exposure, Protexia (72 mg/kg) or saline control was administered intramuscularly. All guinea-pigs treated with Protexia (n=8) survived, compared to no survivors in a saline-treated control group (n=8). Survival following VX and Protexia treatment was associated with minimal incapacitation and observable signs of poisoning, and the mitigation or prevention of the detrimental physiological changes (e.g. seizure, bradycardia and hypothermia) observed in control animals. The opportunity for post-exposure treatment may have utility in both civilian and military scenarios, and this is a promising indication for the use of a bioscavenger. PMID:21620937
Liu, Xu-long; Hong, Wen-xue; Song, Jia-lin; Wu, Zhen-ying
2012-03-01
The skin temperature distribution of a healthy human body exhibits a contralateral symmetry. Some lesions of facial nerve function are associated with an alteration of the thermal distribution of the human body. Since the dissipation of heat through the skin occurs for the most part in the form of infrared radiation, infrared thermography is the method of choice to capture the alteration of the infrared thermal distribution. This paper presents a new method of analysis of the thermal asymmetry named effective thermal area ratio, which is a product of two variables. The first variable is mean temperature difference between the specific facial region and its contralateral region. The second variable is a ratio, which is equal to the area of the abnormal region divided by the total area. Using this new method, we performed a controlled trial to assess the facial nerve function of the healthy subjects and the patients with Bell's palsy respectively. The results show: that the mean specificity and sensitivity of this method are 0.90 and 0.87 respectively, improved by 7% and 26% compared with conventional methods. Spearman correlation coefficient between effective thermal area ratio and the degree of facial nerve function is an average of 0.664. Hence, concerning the diagnosis and assessment of facial nerve function, infrared thermography is a powerful tool; while the effective ther mal area ratio is an efficient clinical indicator.
Li, Yun; Xu, Wen; Cheng, Li-Yu
2017-09-01
Medialization thyroplasty or injection laryngoplasty for unilateral vocal fold paralysis cannot restore mobility of the vocal fold. Recent studies have shown that transplantation of mesenchymal stem cells is effective in the repair of nerve injuries. This study investigated whether adipose-derived stem cell transplantation could repair recurrent laryngeal nerve injury. Rat models of recurrent laryngeal nerve injury were established by crushing with micro forceps. Adipose-derived mesenchymal stem cells (ADSCs; 8 × 10 5 ) or differentiated Schwann-like adipose-derived mesenchymal stem cells (dADSCs; 8 × 10 5 ) or extracellular matrix were injected at the site of injury. At 2, 4 and 6 weeks post-surgery, a higher density of myelinated nerve fiber, thicker myelin sheath, improved vocal fold movement, better recovery of nerve conduction capacity and reduced thyroarytenoid muscle atrophy were found in ADSCs and dADSCs groups compared with the extracellular matrix group. The effects were more pronounced in the ADSCs group than in the dADSCs group. These experimental results indicated that ADSCs transplantation could be an early interventional strategy to promote regeneration after recurrent laryngeal nerve injury.
Comparative study of peripheral neuropathy and nerve regeneration in NOD and ICR diabetic mice.
Homs, Judit; Ariza, Lorena; Pagès, Gemma; Verdú, Enrique; Casals, Laura; Udina, Esther; Chillón, Miguel; Bosch, Assumpció; Navarro, Xavier
2011-09-01
The non-obese diabetic (NOD) mouse was suggested as an adequate model for diabetic autonomic neuropathy. We evaluated sensory-motor neuropathy and nerve regeneration following sciatic nerve crush in NOD males rendered diabetic by multiple low doses of streptozotocin, in comparison with similarly treated Institute for Cancer Research (ICR) mice, a widely used model for type I diabetes. Neurophysiological values for both strains showed a decline in motor and sensory nerve conduction velocity at 7 and 8 weeks after induction of diabetes in the intact hindlimb. However, amplitudes of compound muscle and sensory action potentials (CMAPs and CNAPs) were significantly reduced in NOD but not in ICR diabetic mice. Morphometrical analysis showed myelinated fiber loss in highly hyperglycemic NOD mice, but no significant changes in fiber size. There was a reduction of intraepidermal nerve fibers, more pronounced in NOD than in ICR diabetic mice. Interestingly, aldose reductase and poly(ADP-ribose) polymerase (PARP) activities were increased already at 1 week of hyperglycemia, persisting until the end of the experiment in both strains. Muscle and nerve reinnervation was delayed in diabetic mice following sciatic nerve crush, being more marked in NOD mice. Thus, diabetes of mid-duration induces more severe peripheral neuropathy and slower nerve regeneration in NOD than in ICR mice. © 2011 Peripheral Nerve Society.
The blocking action of choline 2:6-xylyl ether bromide on adrenergic nerves
Exley, K. A.
1957-01-01
Choline 2:6-xylyl ether bromide (TM 10), given systemically to cats in doses of 5 to 15 mg./kg., abolishes the effects of adrenergic nerve stimulation whilst leaving the reactions of the effector organs to adrenaline unimpaired. The effects of a single dose may take up to one hour to become fully established and last for more than twenty-four hours. Apart from transitory ganglionic blockade, cholinergic autonomic nerves are unaffected even by large doses of TM 10. Doses of TM 10 which produce effective blockade do not impair conduction along adrenergic nerve trunks; the drug must, therefore, act at, or close to, the nerve terminals. TM 10 prevents the output of noradrenaline from the spleen on stimulating the splenic nerves; but, in acute experiments, it does not influence the liberation of pressor amines from the stimulated suprarenals. Examination of some ethers related to TM 10 revealed no correlation between TM 10-like adrenergic blocking activity and local anaesthetic activity. The action of TM 10 on adrenergic nerves does not, therefore, seem to be accounted for by axonal block. ImagesFIG. 8 PMID:13460234
Page, C; Cuvelier, P; Biet, A; Strunski, V
2015-06-01
This study aimed to evaluate the impact of intra-operative neuromonitoring of the recurrent laryngeal nerve during total thyroidectomy for benign goitre. A single-centre retrospective study using historical controls was conducted for a 10-year period, comprising a series of 767 patients treated by total thyroidectomy for benign goitre. Of these, 306 had intra-operative neuromonitoring of the recurrent laryngeal nerve and 461 did not. Post-operative laryngeal mobility was assessed in all patients by direct laryngoscopy before hospital discharge and at post-operative follow-up visits. In all, 6 out of 461 patients (1.30 per cent) in the control group and 6 out of 306 patients (1.96 per cent) in the intra-operative neuromonitoring group developed permanent recurrent laryngeal nerve palsy. No statistically significant difference was observed between the two patient groups. Intra-operative neuromonitoring does not appear to affect the post-operative recurrent laryngeal nerve palsy rate or to reliably predict post-operative recurrent laryngeal nerve palsy. However, it can accurately predict good nerve function after thyroidectomy.
Finke, Stefan; Gulrajani, Ramesh M; Gotman, Jean; Savard, Pierre
2013-01-01
The non-invasive localization of the primary sensory hand area can be achieved by solving the inverse problem of electroencephalography (EEG) for N(20)-P(20) somatosensory evoked potentials (SEPs). This study compares two different mathematical approaches for the computation of transfer matrices used to solve the EEG inverse problem. Forward transfer matrices relating dipole sources to scalp potentials are determined via conventional and reciprocal approaches using individual, realistically shaped head models. The reciprocal approach entails calculating the electric field at the dipole position when scalp electrodes are reciprocally energized with unit current-scalp potentials are obtained from the scalar product of this electric field and the dipole moment. Median nerve stimulation is performed on three healthy subjects and single-dipole inverse solutions for the N(20)-P(20) SEPs are then obtained by simplex minimization and validated against the primary sensory hand area identified on magnetic resonance images. Solutions are presented for different time points, filtering strategies, boundary-element method discretizations, and skull conductivity values. Both approaches produce similarly small position errors for the N(20)-P(20) SEP. Position error for single-dipole inverse solutions is inherently robust to inaccuracies in forward transfer matrices but dependent on the overlapping activity of other neural sources. Significantly smaller time and storage requirements are the principal advantages of the reciprocal approach. Reduced computational requirements and similar dipole position accuracy support the use of reciprocal approaches over conventional approaches for N(20)-P(20) SEP source localization.
Microwave processing of gustatory tissues for immunohistochemistry
Bond, Amanda; Kinnamon, John C.
2013-01-01
We use immunohistochemistry to study taste cell structure and function as a means to elucidate how taste receptor cells communicate with nerve fibers and adjacent taste cells. This conventional method, however, is time consuming. In the present study we used taste buds from rat circumvallate papillae to compare conventional immunohistochemical tissue processing with microwave processing for the colocalization of several biochemical pathway markers (PLCβ2, syntaxin-1, IP3R3, α-gustducin) and the nuclear stain, Sytox. The results of our study indicate that in microwave versus conventional immunocytochemistry: (1) fixation quality is improved; (2) the amount of time necessary for processing tissue is decreased; (3) antigen retrieval is no longer needed; (4) image quality is superior. In sum, microwave tissue processing of gustatory tissues is faster and superior to conventional immunohistochemical tissue processing for many applications. PMID:23473796
Value of a novel PGA-collagen tube on recurrent laryngeal nerve regeneration in a rat model.
Suzuki, Hiroshi; Araki, Koji; Matsui, Toshiyasu; Tomifuji, Masayuki; Yamashita, Taku; Kobayashi, Yasushi; Shiotani, Akihiro
2016-07-01
Nerbridge (Toyobo Co., Ltd., Osaka, Japan) is a novel polyglycolic acid (PGA) tube that is filled with collagen fibers and that facilitates nerve fiber expansion and blood vessel growth. It is biocompatible and commercially available, with governmental approval for practical use in Japan. We hypothesized that the PGA-collagen tube would promote regeneration of the recurrent laryngeal nerve (RLN). This hypothesis was examined in a rat axotomy model of the RLN. Prospective animal study. The axotomy model was established by transection of the left RLN in adult Sprague-Dawley rats. The cut ends of the nerve were bridged using Nerbridge (Toyobo Co., Ltd.) with a 1-mm gap (tube-treatment group) or direct sutures (sutured-control group). Left vocal fold mobility, nerve conduction velocity, morphology, and histology were assessed after 15 weeks. Fifteen weeks after treatment, nerve fiber connections were observed macroscopically in both groups, and more clear myelinated fibers and better prevention of laryngeal muscle atrophy were observed in the tube-treatment group compared with the sutured-control group. However, vocal fold movement recovery was not observed in either group, and the conduction velocity of the RLN did not differ between the two groups. Better nerve regeneration was observed in the tube-treatment group. The combination therapy with molecular or gene therapy might be an effective strategy to improve vocal fold movement. The PGA-collagen tube has the potential to promote regeneration of the RLN and to be a scaffold for drug administration in these combination therapies. N/A. Laryngoscope, 126:E233-E239, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
2012-01-01
EMG studies). Data Management and Analysis Descriptive statistics for subject demographics and nerve conduction study variables were calculated using...military N/A Family history of CTS; previous work history as electrician, guitar player 49 (R) None N/A Dental assistant; waiter NCS indicates
Association between Computer Use and Entrapment Neuropathies in the Wrist Region
ERIC Educational Resources Information Center
Colak, S.; Bamac, B.; Colak, T.; Ozbek, A.
2013-01-01
There is general consensus in the literature that computer use is often associated with an increased prevalence of hand and wrist disorders. Symptoms may be associated with specific clinical entities such as peripheral nerve entrapment. Motor and sensory nerve conduction velocity and vibration threshold in the hand of computer users have been…
Human exposure to pesticides is often characterized by chronic low level exposure with intermittent spiked higher exposures. Cholinergic transmission is involved in sensory modulation in the cortex and cerebellum, and therefore may be altered following chlorpyrifos (CPF) exposure...
USDA-ARS?s Scientific Manuscript database
The present study was conducted to elucidate the neuronal pathways between peripheral olfactory and taste sensilla and the synganglion in an Ixodidae tick species. The tarsus of the front legs (olfactory nerves) and the fourth palpal segment (gustatory nerves) of unfed Amblyomma americanum males and...
Micromachined three-dimensional electrode arrays for transcutaneous nerve tracking
NASA Astrophysics Data System (ADS)
Rajaraman, Swaminathan; Bragg, Julian A.; Ross, James D.; Allen, Mark G.
2011-08-01
We report the development of metal transfer micromolded (MTM) three-dimensional microelectrode arrays (3D MEAs) for a transcutaneous nerve tracking application. The measurements of electrode-skin-electrode impedance (ESEI), electromyography (EMG) and nerve conduction utilizing these minimally invasive 3D MEAs are demonstrated in this paper. The 3D MEAs used in these measurements consist of a metalized micro-tower array that can penetrate the outer layers of the skin in a painless fashion and are fabricated using MTM technology. Two techniques, an inclined UV lithography approach and a double-side exposure of thick negative tone resist, have been developed to fabricate the 3D MEA master structure. The MEAs themselves are fabricated from the master structure utilizing micromolding techniques. Metal patterns are transferred during the micromolding process, thereby ensuring reduced process steps compared to traditional silicon-based approaches. These 3D MEAs have been packaged utilizing biocompatible Kapton® substrates. ESEI measurements have been carried out on test human subjects with standard commercial wet electrodes as a reference. The 3D MEAs demonstrate an order of magnitude lower ESEI (normalized to area) compared to wet electrodes for an area that is 12.56 times smaller. This compares well with other demonstrated approaches in literature. For a nerve tracking demonstration, we have chosen EMG and nerve conduction measurements on test human subjects. The 3D MEAs show 100% improvement in signal power and SNR/√area as compared to standard electrodes. They also demonstrate larger amplitude signals and faster rise times during nerve conduction measurements. We believe that this microfabrication and packaging approach scales well to large-area, high-density arrays required for applications like nerve tracking. This development will increase the stimulation and recording fidelity of skin surface electrodes, while increasing their spatial resolution by an order of magnitude or more. Although biopotential electrode systems are not without their challenges, the non-invasive access to neural information, along with the potential for automation with associated electronic and software development, is precisely what makes this technology an excellent candidate for the next generation in diagnostic, therapeutic, and prosthetic devices.
Yamamoto, Hiroto; Sakura, Shinichi; Wada, Minori; Shido, Akemi
2014-12-01
It is believed that local anesthetic injected to obtain circumferential spread around nerves produces a more rapid onset and successful blockade after some ultrasound-guided peripheral nerve blocks. However, evidence demonstrating this point is limited only to the popliteal sciatic nerve block, which is relatively easy to perform by via a high-frequency linear transducer. In the present study, we tested the hypothesis that multiple injections of local anesthetic to make circumferential spread would improve the rate of sensory and motor blocks compared with a single-injection technique for ultrasound-guided subgluteal sciatic nerve block, which is considered a relatively difficult block conducted with a low-frequency, curved-array transducer. Ninety patients undergoing knee surgery were divided randomly into 2 groups to receive the ultrasound-guided subgluteal approach to sciatic nerve block with 20 mL of 1.5% mepivacaine with epinephrine. For group M (the multiple-injection technique), the local anesthetic was injected to create circumferential spread around the sciatic nerve without limitation on the number of needle passes. For group S (the single-injection technique), the number of needle passes was limited to 1, and the local anesthetic was injected to create spread along the dorsal surface of the sciatic nerve, during which no adjustment of the needle tip was made. Sensory and motor blockade were assessed in double-blind fashion for 30 minutes after completion of the block. The primary outcome was sensory blockade of all sciatic components tested, including tibial, superficial peroneal, and sural nerves at 30 minutes after injection. Data from 86 patients (43 in each group) were analyzed. Block execution took more time for group M than group S. The proportion of patients with complete sensory blockade of all sciatic components at 30 minutes after injection was significantly larger for group M than group S (41.9% vs 16.3%, P = 0.018). Complete motor blockade of foot and toes extension also was observed more frequently in group M than in group S (67.4% vs 34.9%, P = 0.005 and 51.2% vs 25.6%, P = 0.027, respectively). When ultrasound-guided subgluteal sciatic nerve block is conducted, multiple injections of local anesthetic to make a circumferential spread around the sciatic nerve improve the rate of sensory and motor blocks compared with a single injection.
Sensory nerve action potentials and sensory perception in women with arthritis of the hand.
Calder, Kristina M; Martin, Alison; Lydiate, Jessica; MacDermid, Joy C; Galea, Victoria; MacIntyre, Norma J
2012-05-10
Arthritis of the hand can limit a person's ability to perform daily activities. Whether or not sensory deficits contribute to the disability in this population remains unknown. The primary purpose of this study was to determine if women with osteoarthritis (OA) or rheumatoid arthritis (RA) of the hand have sensory impairments. Sensory function in the dominant hand of women with hand OA or RA and healthy women was evaluated by measuring sensory nerve action potentials (SNAPs) from the median, ulnar and radial nerves, sensory mapping (SM), and vibratory and current perception thresholds (VPT and CPT, respectively) of the second and fifth digits. All SNAP amplitudes were significantly lower for the hand OA and hand RA groups compared with the healthy group (p < 0.05). No group differences were found for SNAP conduction velocities, SM, VPT, and CPT. We propose, based on these findings, that women with hand OA or RA may have axonal loss of sensory fibers in the median, ulnar and radial nerves. Less apparent were losses in conduction speed or sensory perception.
Sensory nerve action potentials and sensory perception in women with arthritis of the hand
2012-01-01
Background Arthritis of the hand can limit a person’s ability to perform daily activities. Whether or not sensory deficits contribute to the disability in this population remains unknown. The primary purpose of this study was to determine if women with osteoarthritis (OA) or rheumatoid arthritis (RA) of the hand have sensory impairments. Methods Sensory function in the dominant hand of women with hand OA or RA and healthy women was evaluated by measuring sensory nerve action potentials (SNAPs) from the median, ulnar and radial nerves, sensory mapping (SM), and vibratory and current perception thresholds (VPT and CPT, respectively) of the second and fifth digits. Results All SNAP amplitudes were significantly lower for the hand OA and hand RA groups compared with the healthy group (p < 0.05). No group differences were found for SNAP conduction velocities, SM, VPT, and CPT. Discussion We propose, based on these findings, that women with hand OA or RA may have axonal loss of sensory fibers in the median, ulnar and radial nerves. Less apparent were losses in conduction speed or sensory perception. PMID:22575001
Hao, Wu; Tashiro, Syoichi; Hasegawa, Tomoka; Sato, Yuiko; Kobayashi, Tami; Tando, Toshimi; Katsuyama, Eri; Fujie, Atsuhiro; Watanabe, Ryuichi; Morita, Mayu; Miyamoto, Kana; Morioka, Hideo; Nakamura, Masaya; Matsumoto, Morio; Amizuka, Norio; Toyama, Yoshiaki; Miyamoto, Takeshi
2015-07-10
Diabetes mellitus (DM) is frequently accompanied by complications, such as peripheral nerve neuropathy. Schwann cells play a pivotal role in regulating peripheral nerve function and conduction velocity; however, changes in Schwann cell differentiation status in DM are not fully understood. Here, we report that Schwann cells de-differentiate into immature cells under hyperglycemic conditions as a result of sorbitol accumulation and decreased Igf1 expression in those cells. We found that de-differentiated Schwann cells could be re-differentiated in vitro into mature cells by treatment with an aldose reductase inhibitor, to reduce sorbitol levels, or with vitamin D3, to elevate Igf1 expression. In vivo DM models exhibited significantly reduced nerve function and conduction, Schwann cell de-differentiation, peripheral nerve de-myelination, and all conditions were significantly rescued by aldose reductase inhibitor or vitamin D3 administration. These findings reveal mechanisms underlying pathological changes in Schwann cells seen in DM and suggest ways to treat neurological conditions associated with this condition. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.
Anterior transposition of the radial nerve--a cadaveric study.
Yakkanti, Madhusudhan R; Roberts, Craig S; Murphy, Joshua; Acland, Robert D
2008-01-01
The radial nerve is at risk during the posterior plating of the humerus. The purpose of this anatomic study was to assess the extent of radial nerve dissection required for anterior transposition through the fracture site (transfracture anterior transposition). A cadaver study was conducted approaching the humerus by a posterior midline incision. The extent of dissection of the nerve necessary for plate fixation of the humerus fracture was measured. An osteotomy was created to model a humeral shaft fracture at the spiral groove (OTA classification 12-A2, 12-A3). The radial nerve was then transposed anterior to the humeral shaft through the fracture site. The additional dissection of the radial nerve and the extent of release of soft tissue from the humerus shaft to achieve the transposition were measured. Plating required a dissection of the radial nerve 1.78 cm proximal and 2.13 cm distal to the spiral groove. Transfracture anterior transposition of the radial nerve required an average dissection of 2.24 cm proximal and 2.68 cm distal to the spiral groove. The lateral intermuscular septum had to be released for 2.21 cm on the distal fragment to maintain laxity of the transposed nerve. Transfracture anterior transposition of the radial nerve before plating is feasible with dissection proximal and distal to the spiral groove and elevation of the lateral intermuscular septum. Potential clinical advantages of this technique include enhanced fracture site visualization, application of broader plates, and protection of the radial nerve during the internal fixation.
Zhang, Lei; Yang, Wen; Tao, Kaixiong; Song, Yu; Xie, Hongjian; Wang, Jian; Li, Xiaolin; Shuai, Xiaoming; Gao, Jinbo; Chang, Panpan; Wang, Guobin; Wang, Zheng; Wang, Lin
2017-02-01
Chronic nerve compression (CNC), a common form of peripheral nerve injury, always leads to chronic peripheral nerve pain and dysfunction. Current available treatments for CNC are ineffective as they usually aim to alleviate symptoms at the acute phase with limited capability toward restoring injured nerve function. New approaches for effective recovery of CNC injury are highly desired. Here we report for the first time a tissue-engineered approach for the repair of CNC. A genipin cross-linked chitosan-sericin 3D scaffold for delivering nerve growth factor (NGF) was designed and fabricated. This scaffold combines the advantages of both chitosan and sericin, such as high porosity, adjustable mechanical properties and swelling ratios, the ability of supporting Schwann cells growth, and improving nerve regeneration. The degradation products of the composite scaffold upregulate the mRNA levels of the genes important for facilitating nerve function recovery, including glial-derived neurotrophic factor (GDNF), early growth response 2 (EGR2), and neural cell adhesion molecule (NCAM) in Schwann cells, while down-regulating two inflammatory genes' mRNA levels in macrophages, tumor necrosis factor alpha (TNF-α), and interleukin-1 beta (IL-1β). Importantly, our tissue-engineered strategy achieves significant nerve functional recovery in a preclinical CNC animal model by decreasing neuralgia, improving nerve conduction velocity (NCV), accelerating microstructure restoration, and attenuating gastrocnemius muscles dystrophy. Together, this work suggests a promising clinical alternative for treating chronic peripheral nerve compression injury.
Frequency response of the renal vasculature in congestive heart failure.
DiBona, Gerald F; Sawin, Linda L
2003-04-29
The renal vasoconstrictor response to renal nerve stimulation is greater in congestive heart failure (CHF) rats than in control rats. This study tested the hypothesis that the enhanced renal vasoconstrictor response to renal nerve stimulation in CHF is a result of an impairment in the low-pass filter function of the renal vasculature. In response to conventional graded-frequency renal nerve stimulation, the reductions in renal blood flow at each stimulation frequency were greater in CHF rats than control rats. A pseudorandom binary sequence pattern of renal nerve stimulation was used to examine the frequency response of the renal vasculature. Although this did not affect the renal blood flow power spectrum in control rats, there was a 10-fold increase in renal blood flow power over the frequency range of 0.01 to 1.0 Hz in CHF rats. On analysis of transfer function gain, attenuation of the renal nerve stimulation input signal was similar in control and CHF rats over the frequency range of 0.001 to 0.1 Hz. However, over the frequency range of 0.1 to 1.0 Hz, although there was progressive attenuation of the input signal (-30 to -70 dB) in control rats, CHF rats exhibited a flat gain response (-20 dB) without progressive attenuation. The enhanced renal vasoconstrictor response to renal nerve stimulation in CHF rats is caused by an alteration in the low-pass filter function of the renal vasculature, resulting in a greater transfer of input signals into renal blood flow in the 0.1 to 1.0 Hz range.
Moreno-Vicente, Javier; Schiavone-Mussano, Rocío; Clemente-Salas, Enrique; Marí-Roig, Antoni; Jané-Salas, Enric
2015-01-01
Background Coronectomy is the surgical removal of the crown of the tooth deliberately leaving part of its roots. This is done with the hope of eliminating the pathology caused, and since the roots are still intact, the integrity of the inferior alveolar nerve is preserved. Objectives The aim is to carry out a systematic review in order to be able to provide results and conclusions with the greatest scientific evidence possible. Material and Methods A literature review is carried out through the following search engines: Pubmed MEDLINE, Scielo, Cochrane library and EMI. The level of evidence criteria from the Agency for Healthcare Research and Quality was applied, and the clinical trials’ level of quality was analyzed by means of the JADAD criteria. Results The following articles were obtained which represents a total of 17: 1 systematic review, 2 randomized clinical trials and 2 non-randomized clinical trials, 3 cohort studies, 2 retrospective studies, 3 case studies and 4 literature reviews. Conclusions Coronectomy is an adequate preventative technique in protecting the inferior alveolar nerve, which is an alternative to the conventional extraction of third molars, which unlike the former technique, presents a high risk of injury to the inferior alveolar nerve. However, there is a need for new clinical studies, with a greater number of samples and with a longer follow-up period in order to detect potential adverse effects of the retained roots. Key words: Coronectomy, inferior alveolar nerve, nerve injury, wisdom tooth removal, paresthesia, and systematic review. PMID:25858081
BHARDWAJ, Nikha; SAHNI, Priya; SINGHVI, Abhishek; NAYAK, Meghanand; TIWARI, Vineeta
2014-01-01
Branches of the posterior division of the mandibular nerve show various anomalous communications in the infratemporal region. Understanding such communication has relevance in the management of neuropathies and surgical procedures in this region. This study was conducted to explore such communicating branches, anticipating that they might provide information of clinical significance. A total of 15 human cadavers (30 infratemporal regions) were studied to explore such communicating branches in infratemporal region. The branches of the posterior division of the mandibular nerve were carefully dissected, and these branches were studied and analysed for any abnormal course. In one case, a rare type of bilateral communication between the auriculotemporal nerve and the inferior alveolar nerve, forming a loop with no association with any structure, was observed. It is possible that such communicating branches may be associated with delayed regression of the first arch vessels. The clinical implications of these anomalous communications require further detailed study for improved management of neuropathies and surgical procedures. PMID:25977637
Li, Shuo; Guo, Rui-Jun; Liang, Xiao-Ning; Wu, Yue; Cao, Wen; Zhang, Zhen-Ping; Zhao, Wei; Liang, Hai-Dong
2016-01-01
Bell's palsy is a form of temporary facial nerve paralysis that occurs primarily in young adults. Previously, various methods were used to assess outcomes in facial nerve disease. The aim of the present study was to characterize the main branches of the normal and abnormal facial nerve using high-frequency ultrasonography (HFUS). A total of 104 healthy volunteers, 40 patients with acute onset of Bell's palsy and 30 patients who underwent 3-month routine therapy for Bell's palsy disease were included in the study. The healthy volunteers and patients were selected for HFUS examination and VII nerve conduction. The results showed significant differences in nerve diameter, echogenicity, delitescence and amplitude in different groups. Statistically significant correlations were identified for severity grading in one of the experimental groups during HFUS examinations. In conclusion, HFUS as a complementary technique paired with neural electrophysiology may establish the normal values of facial nerve. Additionally, HFUS was beneficial in the process of evaluation and prognosis of Bell's palsy disease.
He, Xingliang; Ao, Qiang; Wei, Yujun; Song, Jinrui
2016-05-01
Peripheral nerve injury is an ongoing challenge in reconstructive surgery. Adipose-derived stem cell (ADSC) application is reported to improve nerve regeneration. In the present study, we evaluated the potential benefit of 34a-ADSCs for never regeneration. Lentiviral vectors containing miRNA-34a were constructed and ADSCs were transduced. The obtained 34a-ADSCs were used to regenerate the sciatic nerve in surgically induced sciatic nerve injury rat model. Sprague-Dawley (SD) rats were randomly divided into two groups, a 34a-ADSC group and an Lv-ADSC group. Functional nerve recovery was assessed by walking track analysis at 12 weeks after surgery. In addition, histology, including light microscopy and transmission electron microscopy, and immunohistochemistry, was utilized to investigate the nerve repair effects of 34a-ADSC. Results showed that reconstruction of the injured sciatic nerve had been significantly enhanced by restoration of nerve continuity and functional recovery in the 34a-ADSC group compared with the Lv-ADSC group. Furthermore, sciatic nerve conduction velocity and compound nerve action potential in the 34a-ADSC group was much higher than that in the Lv-ADSC group (30.72 ± 2.95 m/s vs. 22.73 ± 1.91 m/s, p< 0.0001; 11.93 ± 0.76 mV vs. 9.52 ± 0.53 mV, p = 0.0418). This study raises the possibility of using miRNA-34a overexpressed ADSCs as a promising alternative for nerve regeneration. © 2016 by the Wound Healing Society.
Schmid, Annina B; Coppieters, Michel W
2011-12-01
A high prevalence of dual nerve disorders is frequently reported. How a secondary nerve disorder may develop following a primary nerve disorder remains largely unknown. Although still frequently cited, most explanatory theories were formulated many years ago. Considering recent advances in neuroscience, it is uncertain whether these theories still reflect current expert opinion. A Delphi study was conducted to update views on potential mechanisms underlying dual nerve disorders. In three rounds, seventeen international experts in the field of peripheral nerve disorders were asked to list possible mechanisms and rate their plausibility. Mechanisms with a median plausibility rating of ≥7 out of 10 were considered highly plausible. The experts identified fourteen mechanisms associated with a first nerve disorder that may predispose to the development of another nerve disorder. Of these fourteen mechanisms, nine have not previously been linked to double crush. Four mechanisms were considered highly plausible (impaired axonal transport, ion channel up or downregulation, inflammation in the dorsal root ganglia and neuroma-in-continuity). Eight additional mechanisms were listed which are not triggered by a primary nerve disorder, but may render the nervous system more vulnerable to multiple nerve disorders, such as systemic diseases and neurotoxic medication. Even though many mechanisms were classified as plausible or highly plausible, overall plausibility ratings varied widely. Experts indicated that a wide range of mechanisms has to be considered to better understand dual nerve disorders. Previously listed theories cannot be discarded, but may be insufficient to explain the high prevalence of dual nerve disorders. Copyright © 2011 Elsevier Ltd. All rights reserved.
Wysocka-Mincewicz, Marta; Trippenbach-Dulska, Hanna; Emeryk-Szajewska, Barbara; Zakrzewska-Pniewska, Beata; Kochanek, Krzysztof; Pańkowska, Ewa
2007-01-01
Hypoglycemia is an acute disturbance of energy, especially impacting the central nervous system, but direct influence on peripheral nervous function is not detected. The aim of the study was to establish the influence of hypoglycemic moderate and severe episodes on the function of peripheral nerves, hearing and visual pathway. 97 children with type 1 diabetes (mean age 15.4+/-2.16 years, mean duration of diabetes 8.11+/-2.9 years, mean HbA1c 8,58+/-1.06%), at least 10 years old and with at least 3 years duration of diabetes, were included to study. Nerve conduction studies, visual (VEP) and auditory (ABR) evoked potentials were performed with standard surface stimulating and recording techniques. Moderate hypoglycemic episodes were defined as events of low glycemia requiring help of another person but without loss of consciousness and/or convulsions but recurrent frequently in at least one year. Severe hypoglycemia was defined as events with loss of consciousness and/or convulsions. Univariate ANOVA tests of significance or H Kruskal-Wallis test were used, depending on normality of distribution. The subgroups with a history of hypoglycemic episodes had significant delay in all conduction parameters in the sural nerve (amplitude p<0.05, sensory latency p<0.05, and velocity p<0.005) and in motor potential amplitude of tibial nerve (p<0.005). In ABR wave III latency and interval I-III in subgroups with episodes of hypoglycemia (p<0,05) were significantly prolonged. In analyses of VEP parameters no differences were detected. The study showed influence of hypoglycemic episodes on function of all sural nerve parameters and tibial motor amplitude, and in ABR on wave III and interval I-III. Frequent moderate hypoglycemic episodes were strong risk factors for damage of the peripheral and central nervous systems, comparable with impact of several severe hypoglycemias.
Kim, Ok Sun; Jeong, Seung Min; Ro, Ji Young; Kim, Duck Kyoung; Koh, Young Cho; Ko, Young Sin; Lim, So Dug; Kim, Hae Kyoung
2010-01-01
Occipital neuralgia is a form of headache that involves the posterior occiput in the greater or lesser occipital nerve distribution. Pain can be severe and persistent with conservative treatment. We present a case of intractable occipital neuralgia that conventional therapeutic modalities failed to ameliorate. We speculate that, in this case, the cause of headache could be the greater occipital nerve entrapment by the obliquus capitis inferior muscle. After steroid and local anesthetic injection into obliquus capitis inferior muscles under fluoroscopic and sonographic guidance, the visual analogue scale was decreased from 9-10/10 to 1-2/10 for 2-3 weeks. The patient eventually got both greater occipital neurectomy and partial resection of obliquus capitis inferior muscles due to the short term effect of the injection. The successful steroid and local anesthetic injection for this occipital neuralgia shows that the refractory headache was caused by entrapment of greater occipital nerves by obliquus capitis inferior muscles. PMID:20552081
Mrugacz, Malgorzata; Bakunowicz-Lazarczyk, Alina
2005-01-01
The aim of this study was to quantitatively assess and compare the thickness of the retinal nerve fiber layer (RNFL) in normal and glaucomatous eyes of children using the optical coherence tomograph. The mean RNFL thickness of normal eyes (n=26) was compared with that of glaucomatous eyes (n=26). The eyes were classified into diagnostic groups based on conventional ophthalmological physical examination, Humphrey 30-2 visual fields, stereoscopic optic nerve head photography, and optical coherence tomography. The mean RNFL was significantly thinner in glaucomatous eyes than in normal eyes: 95+/-26.3 and 132+/-24.5 microm, respectively. More specifically, the RNFL was significantly thinner in glaucomatous eyes than in normal eyes in the inferior quadrant: 87+/-23.5 and 122+/-24.2 microm, respectively. The mean and inferior quadrant RFNL thicknesses as measured by the optical coherence tomograph showed a statistically significant correlation with glaucoma. Optical coherence tomography may contribute to tracking of juvenile glaucoma progression. Copyright (c) 2005 S. Karger AG, Basel.
Electromechanical properties of biomembranes and nerves
NASA Astrophysics Data System (ADS)
Heimburg, T.; Blicher, A.; Mosgaard, L. D.; Zecchi, K.
2014-12-01
Lipid membranes are insulators and capacitors, which can be charged by an external electric field. This phenomenon plays an important role in the field of electrophysiology, for instance when describing nerve pulse conduction. Membranes are also made of polar molecules meaning that they contain molecules with permanent electrical dipole moments. Therefore, the properties of membranes are subject to changes in trans-membrane voltage. Vice versa, mechanical forces on membranes lead to changes in the membrane potential. Associated effects are flexoelectricity, piezoelectricity, and electrostriction. Lipid membranes can melt from an ordered to a disordered state. Due to the change of membrane dimensions associated with lipid membrane melting, electrical properties are linked to the melting transition. Melting of the membrane can induce changes in trans-membrane potential, and application of voltage can lead to a shift of the melting transition. Further, close to transitions membranes are very susceptible to piezoelectric phenomena. We discuss these phenomena in relation with the occurrence of lipid ion channels. Close to melting transitions, lipid membranes display step-wise ion conduction events, which are indistinguishable from protein ion channels. These channels display a voltage-dependent open probability. One finds asymmetric current-voltage relations of the pure membrane very similar to those found for various protein channels. This asymmetry falsely has been considered a criterion to distinguish lipid channels from protein channels. However, we show that the asymmetry can arise from the electromechanical properties of the lipid membrane itself. Finally, we discuss electromechanical behavior in connection with the electromechanical theory of nerve pulse transduction. It has been found experimentally that nerve pulses are related to changes in nerve thickness. Thus, during the nerve pulse a solitary mechanical pulse travels along the nerve. Due to electromechanical coupling it is unavoidable that this pulse generates a trans-membrane voltage. In the past, we have proposed that this electromechanical pulse is the origin of the action potential in nerves.
Situ, Jie; Wu, Jian; Wang, Jing-lin; Zhu, De-xiang; Zhang, Jian-jie; Liu, Wei-wei; Qin, Zhuo-hui
2012-05-01
To study the sympathetic skin response (SSR) to the effects of N-hexane on autonomic nerves function in patients with chronic N-hexane poisoning. The subjects in present study included 30 controls and 37 cases with chronic N-hexane poisoning. Also 37 patients were divided into 3 subgroups (mild, moderate and severe poisoning) according to diagnostic criteria of occupational diseases. All subjects were examined by SSR test and nerve conduction velocity (NCV) test. All patients were reexamined by SSR and NCV every 1 ∼ 2 months. The differences in SSR parameters (latency, amplitude) among groups were observed. In the severe poisoning subgroup, the changes of SSR and NCV parameters (conduction velocity, amplitude) in different poisoning stages were observed. There were significant differences in SSR latency of upper extremity among groups and the significant differences in SSR amplitude of upper and lower extremity among groups (P < 0.05). No significant differences in SSR parameters were found between the adjacent groups (P > 0.05). There were significant differences in SSR latency of upper extremity during different periods and the significant differences in SSR amplitude of upper and lower extremity during different periods among all groups (P < 0.05). The change of SSR parameters consistent with that in NCV. The longest SSR latency of upper extremity and the smallest SSR amplitudes of upper and lower extremity appears 1 - 2 months earlier than that of the smallest action potential amplitude. The damage of autonomic nerves induced by N-hexane increased with poisoning progresses. The damage of autonomic nerves corresponded with the damage of myelin sheath of large myelinated nerves, but which appeared 1 - 2 months earlier than the damage of axon of large myelinated nerves. SSR test may serve as a method to detect the damage of autonomic nerves function in patients with chronic N-hexane poisoning.
Conductance changes associated with the secretory potential in the cockroach salivary gland.
Ginsborg, B L; House, C R; Silinsky, E M
1974-02-01
1. Conductance changes in the acini of the cockroach salivary gland have been examined during nerve stimulation by means of two intracellular electrodes placed in the same acinus, the first electrode being used for recording membrane potential and the second for current injection.2. The transient hyperpolarization (secretory potential) in the acinus evoked by nerve stimuli is accompanied by a rise in membrane conductance. The conductance, however, remains high for a longer period than that of the response.3. Applying the analysis of Trautwein & Dudel (1958) to the secretory potentials recorded in the acinus (assumed to behave electrically like a single cell) gives estimates of the ;transmitter equilibrium potential'. The values indicate that the neurotransmitter increases the membrane potassium conductance.4. The hyperpolarization of the acinus evoked by 10(-6)M dopamine in the bathing fluid is also associated with an increase in membrane potassium conductance.
Protein-releasing conductive anodized alumina membranes for nerve-interface materials.
Altuntas, Sevde; Buyukserin, Fatih; Haider, Ali; Altinok, Buket; Biyikli, Necmi; Aslim, Belma
2016-10-01
Nanoporous anodized alumina membranes (AAMs) have numerous biomedical applications spanning from biosensors to controlled drug delivery and implant coatings. Although the use of AAM as an alternative bone implant surface has been successful, its potential as a neural implant coating remains unclear. Here, we introduce conductive and nerve growth factor-releasing AAM substrates that not only provide the native nanoporous morphology for cell adhesion, but also induce neural differentiation. We recently reported the fabrication of such conductive membranes by coating AAMs with a thin C layer. In this study, we investigated the influence of electrical stimulus, surface topography, and chemistry on cell adhesion, neurite extension, and density by using PC 12 pheochromocytoma cells in a custom-made glass microwell setup. The conductive AAMs showed enhanced neurite extension and generation with the electrical stimulus, but cell adhesion on these substrates was poorer compared to the naked AAMs. The latter nanoporous material presents chemical and topographical features for superior neuronal cell adhesion, but, more importantly, when loaded with nerve growth factor, it can provide neurite extension similar to an electrically stimulated CAAM counterpart. Copyright © 2016 Elsevier B.V. All rights reserved.
Graded Positive Feedback in Elasmobranch Ampullae of Lorenzini
NASA Astrophysics Data System (ADS)
Kalmijn, Ad. J.
2003-05-01
The acute electrical sensitivity of marine sharks and rays is the greatest known in the Animal Kingdom. I investigate the possibility that the underlying biophysical principles are the very same as those encountered in the central nervous system of animal and man. The elasmobranch ampullae of Lorenzini detect the weak electric fields originating from the oceanic environment, whereas the nerve cells of the brain detect the electric fields arising, well, from the central nervous system. In responding to electrical signals, the cell membranes of excitable cells behave in different regions of the cell as negative or positive conductors. The negative and positive conductances in series, loaded by the cell's electrolytic environment, constitute a positive feedback circuit. The result may be of an all-or-none nature, as in peripheral nerve conduction, or of a graded nature, as in central processing. In this respect, the operation of the elasmobranch ampullae of Lorenzini is more akin to the graded, integrative processes of higher brain centers than to the conduction of nerve action potentials. Hence, the positive-feedback ampullary circuit promises to help elucidate the functioning of the central nervous system as profoundly as the squid giant axon has served to reveal the process of nervous conduction.
Zhou, Jun-feng; Wang, Yi-guo; Cheng, Liang; Wu, Zhao; Sun, Xiao-dan; Peng, Jiang
2016-01-01
Polypyrrole (PPy) is a biocompatible polymer with good conductivity. Studies combining PPy with electrospinning have been reported; however, the associated decrease in PPy conductivity has not yet been resolved. We embedded PPy into poly(lactic acid) (PLA) nanofibers via electrospinning and fabricated a PLA/PPy nanofibrous scaffold containing 15% PPy with sustained conductivity and aligned topography. There was good biocompatibility between the scaffold and human umbilical cord mesenchymal stem cells as well as Schwann cells. Additionally, the direction of cell elongation on the scaffold was parallel to the direction of fibers. Our findings suggest that the aligned PLA/PPy nanofibrous scaffold is a promising biomaterial for peripheral nerve regeneration. PMID:27904497
The effect of dentinal stimulation on pulp nerve function and pulp morphology in the dog.
Hirvonen, T J; Närhi, M V
1986-11-01
The effect of dentinal stimulation on pulpal nerve responses and pulp morphology has been studied in the dog. Canine tooth (n = 25) dentin was stimulated by drilling, probing, and air-blasting for from two to five hours. Acid-etching was used to open dentinal tubules. All test teeth showed disruption of the odontoblast layer and its separation from the predentin; also, dislocation of odontoblast nuclei into dentinal tubules was found in most cases. Single-fiber (n = 14, conduction velocity = 24.3 +/- 7.4 (SD) m/s) recordings of the responses of canine tooth pulpal nerves to dentinal stimulation were made in ten of the stimulated teeth. No changes in the sensitivity of the nerves to dentinal stimulation could be detected. It is concluded that pulpal nerve function and morphological changes of the pulp are not clearly correlated. The condition of the dentin surface seems to be the important factor.
Neuropathy in non-freezing cold injury (trench foot).
Irwin, M S; Sanders, R; Green, C J; Terenghi, G
1997-01-01
Non-freezing cold injury (trench foot) is characterized, in severe cases, by peripheral nerve damage and tissue necrosis. Controversy exists regarding the susceptibility of nerve fibre populations to injury as well as the mechanism of injury. Clinical and histological studies (n = 2) were conducted in a 40-year-old man with severe non-freezing cold injury in both feet. Clinical sensory tests, including two-point discrimination and pressure, vibration and thermal thresholds, indicated damage to large and small diameter nerves. On immunohistochemical assessment, terminal cutaneous nerve fibres within the plantar skin stained much less than in a normal control whereas staining to von Willebrand factor pointed to increased vascularity in all areas. The results indicate that all nerve populations (myelinated and unmyelinated) were damaged, possibly in a cycle of ischaemia and reperfusion. Images Figure 1 a Figure 1 b Figure 2 a Figure 2 b Figure 3 a Figure 3 b PMID:9306996
Cold-induced peripheral nerve damage: involvement of touch receptors of the foot.
Carter, J L; Shefner, J M; Krarup, C
1988-10-01
A 31-year-old male developed paresthesia and numbness of mainly the right foot following exposure to nonfreezing temperatures under moist conditions over a period of 1 week. The symptoms gradually improved over several months. When seen for electrophysiological studies 6 months after the injury, there was no sensory loss on clinical examination, although he continued to complain of distal numbness of the right foot. The right extensor digitorum brevis muscle was atrophic, and the distal motor latency in the peroneal nerve was prolonged. Conduction studies of the right sural nerve showed a predominantly distal diminution of the SAP evoked by electrical stimulation at the dorsum pedis. Action potentials evoked by tactile stimulation of Pacinian corpuscles showed a prolonged latency on the symptomatic side, suggesting that the most pronounced pathological changes in immersion injury may be localized to the very distal portion of the nerve at the nerve fiber-receptor junction.
Methods for determination of optic nerve blood flow.
Glazer, L. C.
1988-01-01
A variety of studies have been conducted over the past two decades to determine if decreased optic nerve blood flow has a role in the etiology of glaucomatous nerve damage. Five basic methods have been employed in examining blood flow. Invasive studies, utilizing electrodes placed in the optic nerve head, represent one of the first attempts to measure blood flow. More recently, the methodologies have included axoplasmic flow analysis, microspheres, radioactive tracers such as iodoantipyrine, and laser doppler measurements. The results of these studies are inconclusive and frequently contradictory. When the studies are grouped by methodology, only the iodoantipyrine data are consistent. While each of the experimental techniques has limitations, iodoantipyrine appears to have better resolution than either invasive studies or microspheres. PMID:3284212
A Novel Technique for Clinical Assessment of Laryngeal Nerve Conduction: Normal and Abnormal Results
Sulica, Lucian; Carey, Bridget; Branski, Ryan C.
2014-01-01
Objectives/Hypothesis To describe a novel conduction study of the laryngeal nerves, including normal values and abnormal findings. Study Design Prospective nonrandomized. Methods Seventeen healthy adult volunteers, as well as three patients with clinically identified laryngeal neuropathy, underwent low-level brief electrical stimulation of the laryngeal mucosa by means of a wire inserted via a transnasal flexible laryngoscope. Bilateral hookwire electrodes recorded the result in the laryngeal adductor muscles. Results This study yields an early response ipsilateral to the side of stimulation (LR1), which is uniform and consistent (right 5 13.2 6 0.80 msec; left 5 15.2 6 1.20 msec), and late bilateral responses (ipsilateral LR2 [LR2i] and contralateral LR2 [LR2c]), which exhibit greater variation in latency and morphology (right LR2i 5 50.5 6 3.38 msec; left LR2i 5 52.2 msec; right LR2c 5 50.7 6 4.26; left LR2c 5 50.6 6 4.07). Findings in abnormal patients differ significantly from normal, consistent with the distribution of neuropathy. Conclusions We describe a novel, clinically applicable conduction study of laryngeal nerves. Normative electrodiagnostic values and variations of the reflex responses of the laryngeal adductor muscles in response to irritative stimulation of the laryngeal mucosa (Laryngeal Closure Reflex) are proposed. By enabling the determination of electrophysiological parameters of the superior laryngeal and recurrent laryngeal branches of cranial nerve X (CN X), this procedure, which is used as an adjunct to laryngeal electromyography, may provide earlier and more accurate information regarding the extent and grade of nerve injury. Because injury grade relates directly to prognosis, the information derived from this test may have clinical relevance in determining optimal treatment. Level of Evidence 4. PMID:23835889
Gordon, Tessa; Amirjani, Nasim; Edwards, David C; Chan, K Ming
2010-05-01
Electrical stimulation (ES) of injured peripheral nerves accelerates axonal regeneration in laboratory animals. However, clinical applicability of this intervention has never been investigated in human subjects. The aim of this pilot study was to determine the effect of ES on axonal regeneration after surgery in patients with median nerve compression in the carpal tunnel causing marked motor axonal loss. A randomized control trial was conducted to provide proof of principle for ES-induced acceleration of axon regeneration in human patients. Carpel tunnel release surgery (CTRS) was performed and in the stimulation group of patients, stainless steel electrode wires placed alongside the median nerve proximal to the surgical decompression site for immediate 1 h 20 Hz bipolar ES. Subjects were followed for a year at regular intervals. Axonal regeneration was quantified using motor unit number estimation (MUNE) and sensory and motor nerve conduction studies. Purdue Pegboard Test, Semmes Weinstein Monofilaments, and Levine's Self-Assessment Questionnaire were used to assess functional recovery. The stimulation group had significant axonal regeneration 6-8 months after the CTRS when the MUNE increased to 290+/-140 (mean+/-SD) motor units (MU) from 150+/-62 MU at baseline (p<0.05). In comparison, MUNE did not significantly improve in the control group (p>0.2). Terminal motor latency significantly accelerated in the stimulation group but not the control group (p>0.1). Sensory nerve conduction values significantly improved in the stimulation group earlier than the controls. Other outcome measures showed a significant improvement in both patient groups. We conclude that brief low frequency ES accelerates axonal regeneration and target reinnervation in humans. Copyright 2009 Elsevier Inc. All rights reserved.
Symptoms, signs and nerve conduction velocities in patients with suspected carpal tunnel syndrome
2013-01-01
Background To inform the clinical management of patients with suspected carpal tunnel syndrome (CTS) and case definition for CTS in epidemiological research, we explored the relation of symptoms and signs to sensory nerve conduction (SNC) measurements. Methods Patients aged 20–64 years who were referred to a neurophysiology service for investigation of suspected CTS, completed a symptom questionnaire (including hand diagrams) and physical examination (including Tinel’s and Phalen’s tests). Differences in SNC velocity between the little and index finger were compared according to the anatomical distribution of symptoms in the hand and findings on physical examination. Results Analysis was based on 1806 hands in 908 patients (response rate 73%). In hands with numbness or tingling but negative on both Tinel’s and Phalen’s tests, the mean difference in SNC velocities was no higher than in hands with no numbness or tingling. The largest differences in SNC velocities occurred in hands with extensive numbness or tingling in the median nerve sensory distribution and both Tinel’s and Phalen’s tests positive (mean 13.8, 95% confidence interval (CI) 12.6-15.0 m/s). Hand pain and thumb weakness were unrelated to SNC velocity. Conclusions Our findings suggest that in the absence of other objective evidence of median nerve dysfunction, there is little value in referring patients of working age with suspected CTS for nerve conduction studies if they are negative on both Tinel’s and Phalen’s tests. Alternative case definitions for CTS in epidemiological research are proposed according to the extent of diagnostic information available and the relative importance of sensitivity and specificity. PMID:23947775
Tajika, Tsuyoshi; Kobayashi, Tsutomu; Yamamoto, Atsushi; Kaneko, Tetsuya; Takagishi, Kenji
2013-11-01
First, we investigated the accuracy of carpal tunnel syndrome diagnosis by comparing the cross-sectional area of the median nerve measured at the level of proximal inlet of the carpal tunnel with that measured at the level of the distal radioulnar joint on sonography. Second, we evaluated the correlation between sonographic and neurophysiologic findings and clinical findings assessed by the Carpal Tunnel Syndrome Instrument of the Japanese Society for Surgery of the Hand (JSSH). Fifty wrists in 34 patients and 81 wrists in 45 healthy volunteers were examined. The proximal cross-sectional area and the difference (Δ) between the proximal and distal cross-sectional areas were calculated for each wrist. Nerve conduction velocity tests were performed for all patients with carpal tunnel syndrome. The proximal, distal, and Δ cross-sectional areas were compared for the two groups. We examined the correlation between the proximal, distal, and Δ areas, nerve conduction velocity findings, and JSSH scores in the patients. The diagnosis of carpal tunnel syndrome determined by the Δ cross-sectional area was more accurate than the diagnosis determined by the proximal area on receiver operating characteristic curve analysis (P = .006). Statistically significant correlations were found between proximal area, Δ area, and nerve conduction velocity findings (proximal, r = 0.45; P = .0013; Δ, r = 0.44; P = .001). The proximal and distal areas were positively correlated with the JSSH symptom severity score (proximal, r= 0.39; P= .005; distal, r = 0.35; P = .014). The cross-sectional area method using sonography has excellent performance for diagnosing carpal tunnel syndrome. It was useful for measuring the proximal and distal cross-sectional areas to evaluated the symptom severity and for calculating the Δ cross-sectional area to assess motor nerve damage in patients with carpal tunnel syndrome.
Static Magnetic Field Therapy for Carpal Tunnel Syndrome: A Feasibility Study
Colbert, Agatha P.; Markov, Marko S.; Carlson, Nels; Gregory, William L.; Carlson, Hans; Elmer, Patricia J.
2010-01-01
Objectives To assess the feasibility of conducting trials of static magnetic field (SMF) therapy for carpal tunnel syndrome (CTS), to collect preliminary data on the effectiveness of two SMF dosages and to explore the influence of a SMF on median nerve conduction. Design Randomized, double blind, sham controlled trial with 6-week intervention and 12-week follow-up. Setting University hospital outpatient clinics Participants Women and men (N=60), ages 21–65, with electrophysiologically-confirmed CTS diagnosis, recruited from the general population. Interventions Participants wore nightly either neodymium magnets that delivered either 15 or 45mTesla (mT) to the contents of the carpal canal, or a non-magnetic disk. Main Outcome Measures Symptom Severity Scale (SSS) and Function Severity Scale (FSS) of the Boston Carpal Tunnel Questionnaire (BCTQ) and 4 median nerve parameters: sensory distal latency, sensory nerve action potential amplitude, motor distal latency and compound motor action potential amplitude). Results 58 of 60 randomized participants completed the study. There were no significant between-group differences for change in the primary endpoint SSS or for FSS or median nerve conduction parameters. For the SSS and the FSS each group showed a reduction at 6-weeks indicating improvement in symptoms. Conclusions This study demonstrated the feasibility and safety of testing SMF therapy for CTS. There were no between-group differences observed for the BCTQ or median nerve parameters following 6 weeks of SMF therapy. Significant within-group, symptomatic improvements of the same magnitude were experienced by participants in both active and sham magnet groups. Future studies are needed to optimize SMF dosimetry and resolve issues related to the use of sham controls in SMF trials. PMID:20599049
Xu, Xiaofeng; Yang, Xiangdong; Zhang, Ping; Chen, Xiuying; Liu, Huaxiang; Li, Zhenzhong
2012-01-01
A large number of neuroanatomical, neurophysiologic, and neurochemical mechanisms are thought to contribute to the development and maintenance of neuropathic pain. However, mechanisms responsible for neuropathic pain have not been completely delineated. It has been demonstrated that neuropeptide galanin (Gal) is upregulated after injury in the dorsal root ganglion (DRG) and spinal dorsal horn (SDH) where it plays a predominantly antinociceptive role. In the present study, sciatic nerve-pinch injury rat model was used to determine the effects of exogenous Gal on the expression of the Gal and its receptors (GalR1, GalR2) in DRG and SDH, the alterations of pain behavior, nerve conduction velocity (NCV) and morphology of sciatic nerve. The results showed that exogenous Gal had antinociceptive effects in this nerve-pinch injury induced neuropathic pain animal model. It is very interesting that Gal, GalR1 and GalR2 change their expression greatly in DRG and SDH after nerve injury and intrathecal injection of exougenous Gal. Morphological investigation displays a serious damage after nerve-pinch injury and an amendatory regeneration after exogenous Gal treatment. These findings imply that Gal, via activation of GalR1 and/or GalR2, may have neuroprotective effects in reducing neuropathic pain behaviors and improving nerve regeneration after nerve injury.
Pfaus, James G; Manitt, Colleen; Coopersmith, Carol B
2006-12-30
In the female rat, genitosensory input is conveyed to the central nervous system predominantly through the pelvic, pudendal, and hypogastric nerves. The present study examined the relative contribution of those three nerves in the expression of Fos immunoreactivity within brain regions previously shown to be activated by vaginocervical stimulation (VCS). Bilateral transection of those nerves, or sham neurectomy, was conducted in separate groups of ovariectomized, sexually-experienced females. After recovery, females were primed with estrogen and progesterone and given either 50 manual VCSs with a lubricated glass rod over the course of 1 h. VCS increased the number of neurons expressing Fos immunoreactivity in the medial preoptic area, lateral septum, bed nucleus of the stria terminalis, ventromedial hypothalamus, and medial amygdala of sham neurectomized females. Transection of the pelvic nerve reduced Fos immunoreactivity in the medial preoptic area, bed nucleus of the stria terminalis, ventromedial hypothalamus, and medial amygdala, whereas transection of the pudendal nerve had no effect. In contrast, transection of the hypogastric nerve increased Fos immunoreactivity in the medial preoptic area and lateral septum, whereas transaction of the pelvic nerve increased Fos immunoreactivity in the lateral septum, following VCS. All females given VCS, except those with pelvic neurectomy, displayed a characteristic immobility during each application. These data confirm that the pelvic nerve is largely responsible for the neural and behavioral effects of VCS, and support a separate function for the hypogastric nerve.
Intraneural Platelet-Rich Plasma Injections for the Treatment of Radial Nerve Section: A Case Report
García de Cortázar, Unai; Padilla, Sabino; Lobato, Enrique; Delgado, Diego; Sánchez, Mikel
2018-01-01
The radial nerve is the most frequently injured nerve in the upper extremity. Numerous options in treatment have been described for radial nerve injury, such as neurolysis, nerve grafts, or tendon transfers. Currently, new treatment options are arising, such as platelet-rich plasma (PRP), an autologous product with proved therapeutic effect for various musculoskeletal disorders. We hypothesized that this treatment is a promising alternative for this type of nerve pathology. The patient was a healthy 27-year-old man who suffered a deep and long cut in the distal anterolateral region of the right arm. Forty-eight hours after injury, an end-to-end suture was performed without a microscope. Three months after the surgery, an electromyogram (EMG) showed right radial nerve neurotmesis with no tendency to reinnervation. Four months after the trauma, serial intraneural infiltrations of PRP were conducted using ultrasound guidance. The therapeutic effect was assessed by manual muscle testing and by EMG. Fourteen months after the injury and 11 months after the first PRP injection, functional recovery was achieved. The EMG showed a complete reinnervation of the musculature of the radial nerve dependent. The patient remains satisfied with the result and he is able to practice his profession. Conclusions: PRP infiltrations have the potential to enhance the healing process of radial nerve palsy. This case report demonstrates the therapeutic potential of this technology for traumatic peripheral nerve palsy, as well as the apt utility of US-guided PRP injections. PMID:29382110
Interesting and unusual clinical presentations in leprosy at a referral center.
Tayshetye, Pritam U; Pai, Vivek V; Khanolkar, Subhash A; Rathod, Vikram; Ganapati, Ramaswamy
2013-10-01
Leprosy is a disease of declining global endemicity but is still an important health-care problem in India. Pure neural leprosy is an important subset of presentations of leprosy in India. Leprosy is a known disease of the skin and nerves, but cases of pure neural involvement are relatively less. We hereby present 10 cases of pure neural leprosy in which the diagnosis of leprosy was difficult with routine methods. The study was conducted at the main referral center and satellite clinics of our organization. A retrospective analysis of patient records for the last four years was undertaken to identify patients presenting with predominantly neurological manifestations and uncommon presentations including those without skin lesions. The medical records of the patients were used as source of data. All the patients were subjected to a detailed clinical examination and bacteriological examination with slit-skin smears. Investigations like nerve biopsy, electromyography, and nerve conduction studies were done in patients with diagnostic difficulties. Patients presented with neurological symptoms like paresthesias (60%), diminished sensations (40%), nonhealing ulcers (30%), and blisters (20%). All except one had thickened nerves on clinical examination. Slit-skin smear was negative in all but one patient. Nerve biopsy confirmed the diagnosis of leprosy in seven cases. Pure neural leprosy is difficult to diagnose with routine methods. The diagnosis should be considered, especially by neurologists and dermatologists, who are more likely to see such patients with predominant neural manifestations. The diagnosis should be confirmed with nerve biopsy to prevent delay in therapy and associated complications.
Alsubiheen, Abdulrahman; Petrofsky, Jerrold; Daher, Noha; Lohman, Everett; Balbas, Edward; Lee, Haneul
2017-04-01
Diabetes is a disease that leads to damage to the peripheral nerves which may eventually cause balance instability. The purpose of this study was to determine the effect of 8 weeks of Tai Chi (TC) training combined with mental imagery (MI) on soleus H-reflex and nerve conduction velocity (NCV) of the sural and superficial peroneal nerves in people with diabetes. Quasi-experimental, one group pretest-posttest design. Human Research Laboratory. A series of Yang style of Tai Chi classes with mental imagery, one hour, two sessions per week for 8 weeks was done. The Activities-specific Balance Confidence (ABC) Scale, Functional Reach Test (FRT), and One Leg Standing Test (OLS) were measured as functional data. Hoffman reflex (H-reflex), and sural and superficial peroneal NCV were measured as main outcomes. All functional outcomes measures were significantly improved after the intervention (p<0.01). In the H-reflex, there was a significant increase in amplitude (μV) after completing 8 weeks of TC exercise (p=0.02). In the sural nerve, the velocity (p=0.01), amplitude (p=0.01), and latency (p=0.01) were significantly improved between pre and post-test. In the superficial peroneal nerve, significant improvements were observed in (p=0.02) and latency (p=0.01), but not in amplitude (μV) (p>0.05). Combining TC intervention with MI theory showed an improvement in the H-reflex and NCV tests, which suggests improved balance and walking stability. Copyright © 2017 Elsevier Ltd. All rights reserved.
Diniz, Lúcio Ricardo Leite; Portella, Viviane Gomes; da Silva Alves, Kerly Shamira; Araújo, Pâmella Cristina da Costa; de Albuquerque Júnior, Ricardo Luiz Cavalcanti; Cavalcante de Albuquerque, Aline Alice; Coelho-de-Souza, Andrelina Noronha; Leal-Cardoso, José Henrique
2018-01-01
Nonspecific and delayed diagnosis of neurologic damage contributes to the development of neuropathies in patients with severe sepsis. The present study assessed the electrophysiologic parameters related to the excitability and conductibility of sciatic and vagus nerves during early stages of sepsis. Twenty-four hours after sepsis induced by cecal ligation and puncture (CLP) model, sciatic and vagus nerves of septic (CLP group) and control (sham group) rats were removed, and selected electric stimulations were applied to measure the parameters of the first and second components of the compound action potential. The first component originated from fibers with motor and sensory functions (Types A α and A β fibers) with a large conduction velocity (70-120 m/s), and the second component originated from fibers (Type A γ ) with sensorial function. To evaluate the presence of sensorial alterations, the sensitivity to non-noxious mechanical stimuli was measured by using the von Frey test. Hematoxylin and eosin staining of the nerves was performed. We observed an increase of rheobase followed by a decrease in the first component amplitude and a higher paw withdrawal threshold in response to the application of von Frey filaments in sciatic nerves from the CLP group compared to the sham group. Differently, a decrease in rheobase and an increase in the first component amplitude of vagal C fibers from CLP group were registered. No significant morphologic alteration was observed. Our data showed that the electrophysiologic alterations in peripheral nerves vary with the fiber type and might be identified in the first 24 h of sepsis, before clinical signs of neuromuscular disorders.
Oleo gum resin of Ferula assa-foetida L. ameliorates peripheral neuropathy in mice.
Homayouni Moghadam, Farshad; Dehghan, Maryam; Zarepur, Ehsan; Dehlavi, Reyhaneh; Ghaseminia, Fatemeh; Ehsani, Shima; Mohammadzadeh, Golnaz; Barzegar, Kazem
2014-05-28
According to the Chinese, European, Iranian and Indian traditional medicines, oleo gum resin of Ferula assa-foetida (asafoetida) has therapeutic effects on different kinds of diseases. Some of these effects are related to the diseases of nervous system such as hysteresis and convulsion. In recent studies, some anti-epileptic and neuroprotective roles were also considered for it and we examined its possible role on treatment of peripheral neuropathy. in vitro studies were carried out to identify the response of isolated sciatic nerves to different concentrations of oleo gum resin of asafoetida solved in Lock׳s solution. Then, in vivo studies were conducted to evaluate its effect on amelioration of peripheral neuropathy in mice. Peripheral neuropathy was induced by intraperiotoneal injection of high doses of pyridoxine in adult Balb/c male mice. Tail flick tests were performed to identify the incidence of neuropathy in animals. After 10 days treatment with asafoetida, the efficiency of treatment was assessed by behavioral, electrophysiological and histological studies. in vitro experiments confirmed that incubating the nerves in aqueous extract of oleo gum rein of asafoetida increased the amplitude and decreased the latent period of nerve compound action potential (CAP). Nerve conduction velocity (NCV) and amplitude of CAP also improved in asafoetida treated animals. Histological and behavioral studies showed that asafoetida was able to facilitate the healing process in peripheral nerves. in vitro experiments showed that asafoetida is a nerve stimulant and its administration in neuropathic mice exerted neuroprotecting effects through stimulating axonal regeneration and remyelination and decrement of lymphocyte infiltration. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Sodium channels in axons and glial cells of the optic nerve of Necturus maculosa.
Tang, C M; Strichartz, G R; Orkand, R K
1979-11-01
Experiments investigating both the binding of radioactively labelled saxitoxin (STX) and the electrophysiological response to drugs that increase the sodium permeability of excitable membranes were conducted in an effort to detect sodium channels in glial cells of the optic nerve of Necturus maculosa, the mudpuppy. Glial cells in nerves from chronically enucleated animals, which lack optic nerve axons, show no saturable uptake of STX whereas a saturable uptake is clearly present in normal optic nerves. The normal nerve is depolarized by aconitine, batrachotoxin, and veratridine (10(-6)-10(-5) M), whereas the all-glial preparation is only depolarized by veratridine and at concentrations greater than 10(-3) M. Unlike the depolarization caused by veratridine in normal nerves, the response in the all-glial tissue is not blocked by tetrodotoxin nor enhanced by scorpion venom (Leiurus quinquestriatus). In glial cells of the normal nerve, where axons are also present, the addition of 10(-5) M veratridine does lead to a transient depolarization; however, it is much briefer than the axonal response to veratridine in this same tissue. This glial response to veratridine could be caused by the efflux of K+ from the drug-depolarized axons, and is similar to the glial response to extracellular K+ accumulation resulting from action potentials in the axon.
Sodium channels in axons and glial cells of the optic nerve of Necturus maculosa
1979-01-01
Experiments investigating both the binding of radioactively labelled saxitoxin (STX) and the electrophysiological response to drugs that increase the sodium permeability of excitable membranes were conducted in an effort to detect sodium channels in glial cells of the optic nerve of Necturus maculosa, the mudpuppy. Glial cells in nerves from chronically enucleated animals, which lack optic nerve axons, show no saturable uptake of STX whereas a saturable uptake is clearly present in normal optic nerves. The normal nerve is depolarized by aconitine, batrachotoxin, and veratridine (10(-6)-10(-5) M), whereas the all-glial preparation is only depolarized by veratridine and at concentrations greater than 10(-3) M. Unlike the depolarization caused by veratridine in normal nerves, the response in the all-glial tissue is not blocked by tetrodotoxin nor enhanced by scorpion venom (Leiurus quinquestriatus). In glial cells of the normal nerve, where axons are also present, the addition of 10(-5) M veratridine does lead to a transient depolarization; however, it is much briefer than the axonal response to veratridine in this same tissue. This glial response to veratridine could be caused by the efflux of K+ from the drug- depolarized axons, and is similar to the glial response to extracellular K+ accumulation resulting from action potentials in the axon. PMID:512633
A novel electrospun nerve conduit enhanced by carbon nanotubes for peripheral nerve regeneration
NASA Astrophysics Data System (ADS)
Yu, Wenwen; Jiang, Xinquan; Cai, Ming; Zhao, Wen; Ye, Dongxia; Zhou, Yong; Zhu, Chao; Zhang, Xiuli; Lu, Xiaofeng; Zhang, Zhiyuan
2014-04-01
For artificial nerve conduits, great improvements have been achieved in mimicking the structures and components of autologous nerves. However, there are still some problems in conduit construction, especially in terms of mechanical properties, biomimetic surface tomography, electrical conductivity and sustained release of neurotrophic factors or cells. In this study, we designed and fabricated a novel electrospun nerve conduit enhanced by multi-walled carbon nanotubes (MWNTs) on the basis of a collagen/poly(ɛ-caprolactone) (collagen/PCL) fibrous scaffold. Our aim was to provide further knowledge about the mechanical effects and efficacy of MWNTs on nerve conduits as well as the biocompatibility and toxicology of MWNTs when applied in vivo. The results showed that as one component, carboxyl MWNTs could greatly alter the composite scaffold’s hydrophilicity, mechanical properties and degradability. The electrospun fibers enhanced by MWNTs could support Schwann cell adhesion and elongation as a substrate in vitro. In vivo animal studies demonstrated that the MWNT-enhanced collagen/PCL conduit could effectively promote nerve regeneration of sciatic nerve defect in rats and prevent muscle atrophy without invoking body rejection or serious chronic inflammation. All of these results showed that this MWNT-enhanced scaffold possesses good biocompatibility and MWNTs might be excellent candidates as engineered nanocarriers for further neurotrophic factor delivery research.
Finite element modeling of hyper-viscoelasticity of peripheral nerve ultrastructures.
Chang, Cheng-Tao; Chen, Yu-Hsing; Lin, Chou-Ching K; Ju, Ming-Shaung
2015-07-16
The mechanical characteristics of ultrastructures of rat sciatic nerves were investigated through animal experiments and finite element analyses. A custom-designed dynamic testing apparatus was used to conduct in vitro transverse compression experiments on the nerves. The optical coherence tomography (OCT) was utilized to record the cross-sectional images of nerve during the dynamic testing. Two-dimensional finite element models of the nerves were built based on their OCT images. A hyper-viscoelastic model was employed to describe the elastic and stress relaxation response of each ultrastructure of the nerve, namely the endoneurium, the perineurium and the epineurium. The first-order Ogden model was employed to describe the elasticity of each ultrastructure and a generalized Maxwell model for the relaxation. The inverse finite element analysis was used to estimate the material parameters of the ultrastructures. The results show the instantaneous shear modulus of the ultrastructures in decreasing order is perineurium, endoneurium, and epineurium. The FE model combined with the first-order Ogden model and the second-order Prony series is good enough for describing the compress-and-hold response of the nerve ultrastructures. The integration of OCT and the nonlinear finite element modeling may be applicable to study the viscoelasticity of peripheral nerve down to the ultrastructural level. Copyright © 2015 Elsevier Ltd. All rights reserved.
Anatomical basis for sciatic nerve block at the knee level.
Barbosa, Fabiano Timbó; Barbosa, Tatiana Rosa Bezerra Wanderley; da Cunha, Rafael Martins; Rodrigues, Amanda Karine Barros; Ramos, Fernando Wagner da Silva; de Sousa-Rodrigues, Célio Fernando
2015-01-01
Recently, administration of sciatic nerve block has been revised due to the potential benefit for postoperative analgesia and patient satisfaction after the advent of ultrasound. The aim of this study was to describe the anatomical relations of the sciatic nerve in the popliteal fossa to determine the optimal distance the needle must be positioned in order to realize the sciatic nerve block anterior to its bifurcation into the tibial and common fibular nerve. The study was conducted by dissection of human cadavers' popliteal fossa, fixed in 10% formalin, from the Laboratory of Human Anatomy and Morphology Departments of the Universidade Federal de Alagoas and Universidade de Ciências da Saúde de Alagoas. Access to the sciatic nerve was obtained. 44 popliteal fossa were analyzed. The bifurcation of the sciatic nerve in relation to the apex of the fossa was observed. There was bifurcation in: 67.96% below the apex, 15.90% above the apex, 11.36% near the apex, and 4.78% in the gluteal region. The sciatic nerve bifurcation to its branches occurs at various levels, and the chance to succeed when the needle is placed between 5 and 7 cm above the popliteal is 95.22%. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
[Anatomical basis for sciatic nerve block at the knee level].
Barbosa, Fabiano Timbó; Barbosa, Tatiana Rosa Bezerra Wanderley; Cunha, Rafael Martins da; Rodrigues, Amanda Karine Barros; Ramos, Fernando Wagner da Silva; Sousa-Rodrigues, Célio Fernando de
2015-01-01
Recently, administration of sciatic nerve block has been revised due to the potential benefit for postoperative analgesia and patient satisfaction after the advent of ultrasound. The aim of this study was to describe the anatomical relations of the sciatic nerve in the popliteal fossa to determine the optimal distance the needle must be positioned in order to realize the sciatic nerve block anterior to its bifurcation into the tibial and common fibular nerve. The study was conducted by dissection of human cadavers' popliteal fossa, fixed in 10% formalin, from the Laboratory of Human Anatomy and Morphology Departments of the Universidade Federal de Alagoas and Universidade de Ciências da Saúde de Alagoas. Access to the sciatic nerve was obtained. 44 popliteal fossa were analyzed. The bifurcation of the sciatic nerve in relation to the apex of the fossa was observed. There was bifurcation in: 67.96% below the apex, 15.90% above the apex, 11.36% near the apex, and 4.78% in the gluteal region. The sciatic nerve bifurcation to its branches occurs at various levels, and the chance to succeed when the needle is placed between 5 and 7 cm above the popliteal is 95.22%. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.
A novel electrospun nerve conduit enhanced by carbon nanotubes for peripheral nerve regeneration.
Yu, Wenwen; Jiang, Xinquan; Cai, Ming; Zhao, Wen; Ye, Dongxia; Zhou, Yong; Zhu, Chao; Zhang, Xiuli; Lu, Xiaofeng; Zhang, Zhiyuan
2014-04-25
For artificial nerve conduits, great improvements have been achieved in mimicking the structures and components of autologous nerves. However, there are still some problems in conduit construction, especially in terms of mechanical properties, biomimetic surface tomography, electrical conductivity and sustained release of neurotrophic factors or cells. In this study, we designed and fabricated a novel electrospun nerve conduit enhanced by multi-walled carbon nanotubes (MWNTs) on the basis of a collagen/poly(ε-caprolactone) (collagen/PCL) fibrous scaffold. Our aim was to provide further knowledge about the mechanical effects and efficacy of MWNTs on nerve conduits as well as the biocompatibility and toxicology of MWNTs when applied in vivo.The results showed that as one component, carboxyl MWNTs could greatly alter the composite scaffold's hydrophilicity, mechanical properties and degradability. The electrospun fibers enhanced by MWNTs could support Schwann cell adhesion and elongation as a substrate in vitro. In vivo animal studies demonstrated that the MWNT-enhanced collagen/PCL conduit could effectively promote nerve regeneration of sciatic nerve defect in rats and prevent muscle atrophy without invoking body rejection or serious chronic inflammation. All of these results showed that this MWNT-enhanced scaffold possesses good biocompatibility and MWNTs might be excellent candidates as engineered nanocarriers for further neurotrophic factor delivery research.
Duque, Carlos S; Dueñas, Juan P; Marulanda, Marcela; Pérez, Diana; Londoňo, Andres; Roy, Soham; Khadem, Mai Al
2017-03-01
During thyroidectomy and neck dissection surgery for advanced or recurrent metastatic thyroid cancer under intraoperative monitoring, we used the available technology to assess the feasibility of such an intervention to monitor those patients with phrenic nerves at risk. A retrospective review of patients operated on from January 2009 to December 2015 by a single surgeon (CSD) was conducted. Patients who had neck and mediastinal dissection, with or without total thyroidectomy, due to advanced or recurrent metastatic disease to the neck were selected. The procedures were done under intraoperative nerve monitoring using nerve monitoring systems (NIM 2.0 or 3.0; Medtronic, Jacksonville, FL, USA). A total of 19 patients were included in the study, with a mean age of 57.6 years ± 16.3 and a male/female ratio of 10:9. Overall, all patients had an intact phrenic nerve at the conclusion of the surgery. One patient had an aggressive tumor that precluded sacrifice of the left recurrent laryngeal nerve and ipsilateral thoracic duct. The procedure was complicated by a temporary impairment of the diaphragm contraction with intraoperative nerve monitoring as well as a chyle fistula. This was due to the manipulation of the tissue surrounding the phrenic nerve. Intraoperative nerve monitoring of the phrenic nerve offers the surgeon a "potential" method of ensuring phrenic nerve integrity in cases of advanced thyroid cancers with gross level IV metastatic disease. Further prospective studies are needed to assess the risks of this intervention and evaluate the method of recording diaphragm contraction movement.
Antoniadou, Eleni V; Ahmad, Rezal K; Jackman, Richard B; Seifalian, Alexander M
2011-01-01
Composite materials based on the coupling of conductive organic polymers and carbon nanotubes have shown that they possess properties of the individual components with a synergistic effect. Multi-wall carbon nanotube (MWCNT)/ polymer composites are hybrid materials that combine numerous mechanical, electrical and chemical properties and thus, constitute ideal biomaterials for a wide range of regenerative medicine applications. Although, complete dispersion of CNT in a polymer matrix has rarely been achieved, in this study we have succeeded high dispersibility of CNT in POSS-PCU and POSS-PCL, novel polymers based on polyprolactone and polycarbonate polyurethane (PCU) and poly(caprolactoneurea)urethane both having incorporated polyhedral oligomeric silsesquioxane (POSS). We report the synthesis and characterization of a novel biomaterial that possesses unique properties of being electrically conducting and thus being capable of electronic interfacing with tissue. To this end, POSS-PCU/MWCNT composite can be used as a biomaterial for the development of nerve guidance channels to promote nerve regeneration and POSS-PCL/MWCNT as a substrate to increase electronic interfacing between neurons and micro-machined electrodes for potential applications in neural probes, prosthetic devices and brain implants.
Nerve conduction velocity in human limbs with late sequelae after local cold injury.
Arvesen, A; Wilson, J; Rosén, L
1996-06-01
Cold-induced neuropathy may play a dominant role in the long-term sequelae with cold sensitivity after local cold injuries (LCIs). Somatosensory functions were assessed and nerve conduction velocity (NCV) and motor distal delay (MDD) were measured in the limbs of 31 Norwegian former soldiers with persistent cold intolerance 3-4 years after the primary LCI. NCV measurements were performed in 24 lower and 16 upper extremities. NCV was related to degree of overall subjective complaints quantified by means of a visual analogue scale (VAS). Motor (MNCV) and sensory conduction velocity (SNCV) in the lower extremities and SNCV in the hands were significantly decreased compared with controls. MDD was pathologically increased in the feet. NCV of the forearms ranged from normal to significant reduction. The more pronounced effect on the lower extremities may be caused by deeper cooling of the calves compared with forearms for several reasons. No significant associations were found between VAS and NCV except for the right median nerve. NCV measurements may provide objective findings in cold-injured patients and in those with few or no conspicuous clinical signs.
Retrospective Study of Salinomycin Toxicosis in 66 Cats
Pakozdy, Akos; Challande-Kathman, Iris; Doherr, Marcus; Cizinauskas, Sigitas; Wheeler, Simon J.; Oevermann, Anna; Jaggy, Andre
2010-01-01
We examined 66 cats with salinomycin intoxication. Salinomycin caused different LMN signs of varying degrees of severity in all cases. Changes in blood work were unspecific, with the most frequent being increased serum creatine kinase activity, leukocytosis, and increased liver enzymes. Pathological electrodiagnostic findings: fibrillation potentials and positive sharp waves were detected in 10 cases, motor nerve conductance velocity was mildly decreased in 8/12 cats, and sensory nerve conductance velocity and repetitive nerve stimulation were normal in all examined cases. In five cases the peripheral neuropathy was confirmed by pathohistology. Fluid therapy and supportive care were used as therapy and 52 cats recovered completely. The probability for complete remission was significantly different between mildly and severely affected cases. It seems that the severity of clinical signs and prognosis correlate well with the amount of toxin ingested. We conclude that early recognition and decontamination combined with supportive care results in complete recovery. PMID:20445777
[Effectiveness of magnetotherapy in optic nerve atrophy. A preliminary study].
Zobina, L V; Orlovskaia, L S; Sokov, S L; Sabaeva, G F; Kondé, L A; Iakovlev, A A
1990-01-01
Magnetotherapy effects on visual functions (vision acuity and field), on retinal bioelectric activity, on conductive vision system, and on intraocular circulation were studied in 88 patients (160 eyes) with optic nerve atrophy. A Soviet Polyus-1 low-frequency magnetotherapy apparatus was employed with magnetic induction of about 10 mT, exposure 7-10 min, 10-15 sessions per course. Vision acuity of patients with its low (below 0.04 diopters) values improved in 50 percent of cases. The number of patients with vision acuity of 0.2 diopters has increased from 46 before treatment to 75. Magnetotherapy improved ocular hemodynamics in patients with optic nerve atrophy, it reduced the time of stimulation conduction along the vision routes and stimulated the retinal ganglia cells. The maximal effect was achieved after 10 magnetotherapy sessions. A repeated course carried out in 6-8 months promoted a stabilization of the process.
Peripheral nerve magnetic stimulation: influence of tissue non-homogeneity
Krasteva, Vessela TZ; Papazov, Sava P; Daskalov, Ivan K
2003-01-01
Background Peripheral nerves are situated in a highly non-homogeneous environment, including muscles, bones, blood vessels, etc. Time-varying magnetic field stimulation of the median and ulnar nerves in the carpal region is studied, with special consideration of the influence of non-homogeneities. Methods A detailed three-dimensional finite element model (FEM) of the anatomy of the wrist region was built to assess the induced currents distribution by external magnetic stimulation. The electromagnetic field distribution in the non-homogeneous domain was defined as an internal Dirichlet problem using the finite element method. The boundary conditions were obtained by analysis of the vector potential field excited by external current-driven coils. Results The results include evaluation and graphical representation of the induced current field distribution at various stimulation coil positions. Comparative study for the real non-homogeneous structure with anisotropic conductivities of the tissues and a mock homogeneous media is also presented. The possibility of achieving selective stimulation of either of the two nerves is assessed. Conclusion The model developed could be useful in theoretical prediction of the current distribution in the nerves during diagnostic stimulation and therapeutic procedures involving electromagnetic excitation. The errors in applying homogeneous domain modeling rather than real non-homogeneous biological structures are demonstrated. The practical implications of the applied approach are valid for any arbitrary weakly conductive medium. PMID:14693034
Recurrent laryngeal nerve landmarks during thyroidectomy.
Ngo Nyeki, A-R; Njock, L-R; Miloundja, J; Evehe Vokwely, J-E; Bengono, G
2015-11-01
This study was designed to describe the various anatomical relations of the recurrent laryngeal nerve (RLN) during thyroid surgery in a Central African population. A prospective study was conducted between January 2012 and December 2012 in 5 otorhinolaryngology and head and neck surgery departments in Cameroon and Gabon. All patients undergoing total or subtotal thyroidectomy or loboisthmectomy with recurrent laryngeal nerve dissection, with no history of previous thyroid surgery, RLN dissection or tumour infiltration of the RLN, were included. Fifty-six patients were included, corresponding to 36 loboisthmectomies and 20 total or subtotal thyroidectomies. A total of 62 recurrent laryngeal nerves were identified: 32 on the right and 30 on the left. The course of the recurrent laryngeal nerve in relation to branches of the inferior thyroid artery (ITA) was retrovascular in 53.1% of cases on the right and 76.6% of cases on the left; transvascular in 15.6% of cases on the right and 13.4% of cases on the left. The course of the recurrent laryngeal nerve was modified by thyroid disease in 12.9% of cases. Six cases (9.7%) of extralaryngeal division of the recurrent laryngeal nerve were observed. No case of non-recurrent nerve was observed in this series. The anatomical relations of the recurrent laryngeal nerve with the inferior thyroid artery were very inconstant in this series and were predominantly retrovascular or transvascular in relation to the branches of the artery. The presence of extralaryngeal branches and modification of the course of the nerve by thyroid disease also introduced additional difficulties during recurrent laryngeal nerve dissection. The anatomical relations of the right recurrent laryngeal nerve in this African population differ from the classically described prevascular course. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Xue, Ning; Martinez, Ignacio Delgado; Sun, Jianhai; Cheng, Yuhua; Liu, Chunxiu
2018-07-30
Vagus nerve stimulation is an emerging bioelectronic medicine to modulate cardiac function, as the nerve provides parasympathetic innervation to the heart. In this study, we developed a polyimide based 2D cuff electrode to wrap around on the vagus nerve. Thanks to the tiny size and bendable protruding structure of the contact tips of the device, the electrode sites are able to flexibly bend to touch the nerve, selectively record and stimulate the vagus nerve. Gold, platinum and platinum black materials were chosen to compose the electrodes for nerve stimulation and recording, respectively. Since the platinum black has ~30 times larger charge delivery capacity (CDC) than gold, Pt black electrode is used for nerve stimulation. The electrochemical impedance spectroscopy and cyclic voltammetry measurement of the three materials were conducted in vitro, revealing the results of 405 kΩ, 41 kΩ, 10.5 kΩ, @1 kHz and 0.81 mC/cm 2 , 4.26 mC/cm 2 , 25.5 mC/cm 2 , respectively (n = 3). The cuff electrodes were implanted into the right-sided vagus nerve of rats for in vivo experiment. Biphasic current configuration was implemented for nerve stimulation with frequency of 10 Hz, pulse during of 300 μs and various currents stimulus. The result shows the heart beat frequency drops up to 36% during the stimulation and was able to return the regular frequency as stimulation was removed. Subsequently, the vagus nerve signals were recorded with the four channel cuff electrodes. The magnitude of the compound nerve action potentials (CNAPs) is ~10 μV and the signal to noise ratio (SNR) is ~20. Copyright © 2018 Elsevier B.V. All rights reserved.
Lv, Ying; Zhao, Shaozhen
2018-03-26
There are well-acknowledged clinical or pre-clinical measurements concerning diabetic peripheral neuropathy(DPN). The current gold standard for diagnosis of diabetic peripheral neuropathy is nerve conduction suitable for detecting large nerve fiber function[1] and intraepidermal nerve fiber density assessment for small fiber damage evaluation[2]. The lack of a sensitive, non-invasive, and repeatable endpoint to measure changes in small nerve fibers is a major factor holding back clinical trials for the treatment of diabetic peripheral neuropathy. As cornea is the most densely innerved tissue, assessing corneal nerves' structure and function will be promising to predict and assess the degree of DPN [3]. In the diabetic micro-environment, damaged corneal nerves lead to decreased corneal sensitivity, both of which resulting in abnormal tear function. According to this theory, the measurements of nerve structure, corneal sensitivity, tear secretion and tear components, to some extent, can reveal and assess the state of corneal neuropathy. This review focuses on summarizing the knowledge of the latest detective methods of diabetic corneal neuropathy, popular in use or possible to further in study and be applied into clinical practice. Copyright © 2018 Elsevier B.V. All rights reserved.
Wang, Cheng; Chen, Shijiu; Wang, Zengtao
2014-09-01
The aim of this study is to characterize and dynamically monitor the progress of peripheral neuropathy induced by n-hexane by electromyography and nerve conduction velocity (NCV-EMG). Twenty-five patients with n-hexane poisoning from an electronic company were investigated in the year 2009. The occupational history of these workers was collected, and toxic substance exposure was identified. Neurologic inspection and regular NCV-EMG inspection were performed for all patients upon hospital admission and after 3, 6, and 12 months of treatment. NCV-EMG results shown that patients with n-hexane poisoning have simultaneous damage on motor and sensory nerves, of which sensory nerve damage was more severe. Motor nerves of the lower limbs were severe damaged than those of the upper limbs; whereas injury of sensory nerve in the upper limbs was more severe than that of the lower limbs. After treatment, clinical signs and symptoms of the patients were significantly improved. NCV-EMG result showed a delayed worsening at 3 months then gradually recovered after 12 months. Recovery of the motor nerve was better compared with sensory nerve, with upper limbs faster than that of the lower limbs.
Sonographic evaluation of peripheral nerves in subtypes of Guillain-Barré syndrome.
Mori, Atsuko; Nodera, Hiroyuki; Takamatsu, Naoko; Maruyama-Saladini, Keiko; Osaki, Yusuke; Shimatani, Yoshimitsu; Kaji, Ryuji
2016-05-15
Sonography of peripheral nerves can depict alteration of nerve sizes that could reflect inflammation and edema in inflammatory and demyelinating neuropathies. Guillain-Barré syndrome (GBS). Information on sonographic comparison of an axonal subtype (acute motor [and sensory] axonal neuropathy [AMAN and AMSAN]) and a demyelinating subtype (acute inflammatory demyelinating polyneuropathy [AIDP]) has been sparse. Sonography of peripheral nerves and cervical nerve roots were prospectively recorded in patients with GBS who were within three weeks of disease onset. Five patients with AIDP and nine with AMAN (n=6)/AMSAN (n=3) were enrolled. The patients with AIDP showed evidence of greater degrees of demyelination (e.g., slower conduction velocities and increased distal latencies) than those with AMAN/AMSAN. The patients with AIDP tended to show enlarged nerves in the proximal segments and in the cervical roots, whereas the patients with AMAN/AMSAN had greater enlargement in the distal neve segment, especially in the median nerve (P = 0.03; Wrist-axilla cross-sectional ratio). In this small study, two subtypes of GBS showed different patterns of involvement that might reflect different pathomechanisms. Copyright © 2016 Elsevier B.V. All rights reserved.
Functionalized polymer nanofibre membranes for protection from chemical warfare stimulants
NASA Astrophysics Data System (ADS)
Ramaseshan, Ramakrishnan; Sundarrajan, Subramanian; Liu, Yingjun; Barhate, R. S.; Lala, Neeta L.; Ramakrishna, S.
2006-06-01
A catalyst for the detoxification of nerve agents is synthesized from β-cyclodextrin (β-CD) and o-iodosobenzoic acid (IBA). Functionalized polymer nanofibre membranes from PVC polymer are fabricated with β-CD, IBA, a blend of β-CD+IBA, and the synthesized catalyst. These functionalized nanofibres are then tested for the decontamination of paraoxon, a nerve agent stimulant, and it is observed that the stimulant gets hydrolysed. The kinetics of hydrolysis is investigated using UV spectroscopy. The rates of hydrolysis for different organophosphate hydrolyzing agents are compared. The reactivity and amount of adsorption of these catalysts are of higher capacity than the conventionally used activated charcoal. A new design for protective wear is proposed based on the functionalized nanofibre membrane.
Churg-Strauss Syndrome as an Unusual Cause of Dysphagia: Case Report.
Park, Jihye; Im, Sun; Moon, Su-Jin; Park, Geun-Young; Jang, Yongjun; Kim, Yeonjin
2015-06-01
Systemic vasculitis is a rare disease, and the diagnosis is very difficult when patient shows atypical symptoms. We experienced an unusual case of dysphagia caused by Churg-Strauss syndrome with lower cranial nerve involvement. A 74-year-old man, with a past history of sinusitis, asthma, and hearing deficiency, was admitted to our department for evaluation of dysphagia. He also complained of recurrent bleeding of nasal cavities and esophagus. Brain magnetic resonance imaging did not show definite abnormality, and electrophysiologic findings were suggestive of mononeuritis multiplex. Dysphagia had not improved after conventional therapy. Biopsy of the nasal cavity showed extravascular eosinophilic infiltration. All these findings suggested a rare form of Churg-Strauss syndrome involving multiple lower cranial nerves. Dysphagia improved after steroid therapy.
Gallina, Alessio; Peters, Sue; Neva, Jason L; Boyd, Lara A; Garland, S Jayne
2017-06-01
The objective of this study was to determine whether motor evoked potentials (MEPs) elicited with transcranial magnetic stimulation and measured with conventional bipolar electromyography (EMG) are influenced by crosstalk from non-target muscles. MEPs were recorded in healthy participants using conventional EMG electrodes placed over the extensor carpi radialis muscle (ECR) and high-density surface EMG (HDsEMG). Fifty MEPs at 120% resting and active motor threshold were recorded. To determine the contribution of ECR to the MEPs, the amplitude distribution across HDsEMG channels was correlated with EMG activity recorded during a wrist extension task. Whereas the conventional EMG identified MEPs from ECR in >90% of the stimulations, HDsEMG revealed that spatial amplitude distribution representative of ECR activation was observed less frequently at rest than while holding a contraction (P < 0.001). MEPs recorded with conventional EMG may contain crosstalk from non-target muscles, especially when the stimulation is applied at rest. Muscle Nerve 55: 828-834, 2017. © 2016 Wiley Periodicals, Inc.
[Conduction block: a notion to let through].
Fournier, E
2012-12-01
Historical study of electrodiagnosis indicates that nerve conduction block is an old notion, used as early as the second century by Galien and then early in the 19th by physiologists such as Müller and Mateucci. Although introduced into the field of human pathology by Mitchell in 1872, who used it to study nerve injuries, and then by Erb in 1874 to study radial palsy, the contribution of nerve conduction blocks to electrodiagnosis was not exploited until the 1980s. At that time, attempts to improve early diagnosis of Guillain-Barré syndrome showed that among the electrophysiological consequences of demyelination, conduction block was the most appropriate to account for the paralysis. At the same time, descriptions of neuropathies characterized by conduction blocks led to considering conduction block as a major electrophysiological sign. Why was it so difficult for this sign to be retained for electrodiagnosis? Since the notion is not always associated with anatomical lesions, it doesn't fit easily into anatomoclinical reasoning, but has to be thought of in functional terms. Understanding how an uninjured axon could fail to conduct action potentials leads to an examination of the intimate consequences of demyelinations and axonal dysfunctions. But some of the difficulty encountered in adding this new old sign to the armamentarium of electrophysiological diagnosis was related to the technical precautions required to individualize a block. Several pitfalls have to be avoided if a conduction block is to be afforded real diagnostic value. Similar precautions and discussions are also needed to establish an opposing sign, the "excitability block" or "inverse block". Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Conduction velocity and refractory period of single motor nerve fibres in antecedent poliomyelitis.
Borg, K; Borg, J
1987-01-01
The axonal conduction velocity and the axonal refractory period were determined using electromyographic techniques for 60 single motor units in 11 patients with antecedent poliomyelitis. The results were compared with previous observations in healthy subjects as well as subjects with motor neuron disease. In antecedent poliomyelitis there was a reduced proportion of nerve fibres with low conduction velocity as compared with the findings in healthy subjects. The mean value of the axonal conduction velocities in antecedent poliomyelitis (42.4 +/- 3.7 m/s, M +/- SD) was significantly higher (p less than 0.01) while in motor neuron disease the corresponding value (35.2 +/- 7.8 m/s) was significantly lower (p less than 0.005) than in healthy subjects (39.8 +/- 4.9 m/s). In antecedent poliomyelitis the conduction velocity and refractory period were related as in healthy subjects while abnormally long refractory periods were observed in motor neuron disease. Images PMID:3585356
Contribution of Rho-kinase to membrane excitability of murine colonic smooth muscle.
Bayguinov, O; Dwyer, L; Kim, H; Marklew, A; Sanders, K M; Koh, S D
2011-06-01
The Rho-kinase pathway regulates agonist-induced contractions in several smooth muscles, including the intestine, urinary bladder and uterus, via dynamic changes in the Ca(2+) sensitivity of the contractile apparatus. However, there is evidence that Rho-kinase also modulates other cellular effectors such as ion channels. We examined the regulation of colonic smooth muscle excitability by Rho-kinase using conventional microelectrode recording, isometric force measurements and patch-clamp techniques. The Rho-kinase inhibitors, Y-27632 and H-1152, decreased nerve-evoked on- and off-contractions elicited at a range of frequencies and durations. The Rho-kinase inhibitors decreased the spontaneous contractions and the responses to carbachol and substance P independently of neuronal inputs, suggesting Y-27632 acts directly on smooth muscle. The Rho-kinase inhibitors significantly reduced the depolarization in response to carbachol, an effect that cannot be due to regulation of Ca(2+) sensitization. Patch-clamp experiments showed that Rho-kinase inhibitors reduce GTPγS-activated non-selective cation currents. The Rho-kinase inhibitors decreased contractions evoked by nerve stimulation, carbachol and substance P. These effects were not solely due to inhibition of the Ca(2+) sensitization pathway, as the Rho-kinase inhibitors also inhibited the non-selective cation conductances activated by excitatory transmitters. Thus, Rho-kinase may regulate smooth muscle excitability mechanisms by regulating non-selective cation channels as well as changing the Ca(2+) sensitivity of the contractile apparatus. © 2011 The Authors. British Journal of Pharmacology © 2011 The British Pharmacological Society.
Toxicology of organophosphorus compounds in view of an increasing terrorist threat.
Worek, Franz; Wille, Timo; Koller, Marianne; Thiermann, Horst
2016-09-01
The implementation of the Chemical Weapon Convention (CWC), prohibiting the development, production, storage and use of chemical weapons by 192 nations and the ban of highly toxic OP pesticides, especially class I pesticides according to the WHO classification, by many countries constitutes a great success of the international community. However, the increased interest of terrorist groups in toxic chemicals and chemical warfare agents presents new challenges to our societies. Almost seven decades of research on organophosphorus compound (OP) toxicology was mainly focused on a small number of OP nerve agents despite the fact that a huge number of OP analogues, many of these agents having comparable toxicity to classical nerve agents, were synthesized and published. Only limited physicochemical, toxicological and medical information on nerve agent analogues is available in the open literature. This implies potential gaps of our capabilities to detect, to decontaminate and to treat patients if nerve agent analogues are disseminated and may result in inadequate effectiveness of newly developed countermeasures. In summary, our societies may face new, up to now disregarded, threats by toxic OP which calls for increased awareness and appropriate preparedness of military and civilian CBRN defense, a broader approach for new physical and medical countermeasures and an integrated system of effective detection, decontamination, physical protection and treatment.
NASA Astrophysics Data System (ADS)
Perkins, William C.; Lagoda, Gwen A.; Burnett, Arthur L.; Fried, Nathaniel M.
2014-03-01
Optical nerve stimulation (ONS) has been commonly performed in the laboratory using high-power, pulsed, infrared (IR) lasers including Holmium:YAG, diode, and Thulium fiber lasers. However, the relatively high cost of these lasers in comparison with conventional electrical nerve stimulation (ENS) equipment may represent a significant barrier to widespread adoption of ONS. Optical stimulation of the prostate cavernous nerves (CN's) has recently been reported using lower cost, continuous-wave (CW), all-fiber-based diode lasers. This preliminary study describes further miniaturization and cost reduction of the ONS system in the form of a compact, lightweight, cordless, and inexpensive IR laser. A 140-mW, 1560-nm diode laser was integrated with a green aiming beam and delivery optics into a compact ONS system. Surface and subsurface ONS was performed in a total of 5 rats, in vivo, with measurement of an intracavernous pressure (ICP) response during CW laser irradiation for 30 s with a spot diameter of 0.7 mm. Short-term, CW ONS of the prostate CN's is feasible using a compact, inexpensive, batterypowered IR laser diode system. This ONS system may represent an alternative to ENS for laboratory studies, and with further development, a handheld option for ONS in the clinic to identify and preserve the CN's during prostate cancer surgery.
De, Abhishek; Hasanoor Reja, Abu Hena; Aggarwal, Ishad; Sen, Sumit; Sil, Amrita; Bhattacharya, Basudev; Sharma, Nidhi; Ansari, Asad; Sarda, Aarti; Chatterjee, Gobinda; Das, Sudip
2017-01-01
Background: Pure neural leprosy (PNL) still remains a diagnostic challenge because of the absence of sine qua non skin lesions of leprosy and a confirmatory diagnostic method. The authors had earlier described a simple yet objective technique of combining fine needle aspiration cytology (FNAC) coupled with a multiplex polymerase chain reaction (PCR) in a pilot study, wherein the technique showed promise of a reliable diagnostic tool. In the pursuit of further evidence, the authors carried out a 4-year study with PNL cases to find the efficacy and reliability of the said method in a larger sample size. Aim: This study was conducted to find the efficacy, reliability, and reproducibility of FNAC coupled with multiplex PCR and Ziehl-Neelsen (ZN) staining in identifying the cases of PNL. Materials and Methods: All cases that were suspected to be suffering from PNL, following evaluation by two independent observers were included in the study and were subjected to FNAC from the affected nerve, and the aspirates were evaluated for cytology, ZN staining, and multiplex PCR for Mycobacterium leprae genome. In addition, serum anti-PGL1 levels were also performed in all the study subjects. Fifteen non-PNL cases were also included in the control arm. Results: A total of 47 cases were included in the test arm and subjected to FNAC. Conventional ZN staining could demonstrate acid-fast bacilli (AFB) in only 15 out of 47 cases (31.91%) while M. leprae DNA could be elicited in 37 (78.72%) cases by the multiplex PCR. Only 13 (27.65%) out of 47 cases showed anti-PGLI-1 antibody positivity. On cytological examination of the nerve aspirates, only 11 (23.40%) cases showed epithelioid cells whereas nonspecific inflammation was seen in 26 (75.60%) cases. Conclusion: The results of this study conducted over a larger sample size corroborate with the findings of our pilot study. In a resource poor set up, FNAC in combination with ZN staining and multiplex PCR is a rapid, simple, and easily performed test, which can give a reproducible and objective diagnosis in cases of PNL. PMID:29263539
NASA Astrophysics Data System (ADS)
Hoopes, P. J.; Eskey, Cliff J.; Attawia, Mohammed; Patel, Samit J.; Ryan, T. P.; Pellegrino, Richard; Bergeron, Jeffrey A.
2005-04-01
Pathological involvement of the basivertebral nerve (BVN), an intraosseous vertebral nerve, may play a significant role in some forms of back pain. This study was designed to assess the feasibility and effects of thermal ablation of the lumbar basivertebral nerve in mature sheep. Sixteen adult female sheep weighing 65-80 kg were anesthetized and positioned for ventral recumbent surgery. Under fluoroscopic guidance, two bilarterally oposed 5mm active length rediofrequency (RF) electrodes (1.65mm diameter were perfutaneously placed in select lumbar vertebrae at a relative angle of 70 degrees with a 5 mm tip separation. The elctrodes were advanced to the region of the vertebral bodies which contained the BVN. A thermal dose of 95° C/720 seconds was administered. Animals were survived for 2, 14, 90, or 180 days post-treatment. Clinical, radiologic and pathologic investigations were performed to determine the effect of the heat on the BVN and associated tissues. Thermal damage to the basivertebral neurovascular bundle was characterized by early hemorrhage and necrosis, followed by inflammation and fibrosis. Although there wasa significant revascularization of the treated bone marow regions, there was no evidence of basivertebral nerve survival or regeneration regeneration. In addition to ablation of teh basivertebral nerovascular bundle, the areas receiving the greatest treatment demonstrated initial mild local osteolysis and demineralization of the vertebral body bone and regional depopulation of the vertebral bone marrow cellular elements. Significant bone remodeling in the affected areas had begun by 14 days post-treatment. Bone remodeling was characterized by conventional osteoblast proliferation, osteoid deposition, and mineralization. This study demonstrated the ability to accurately, reproducibly, and safely ablate the basivertebral nerve and neurovascular bundle in mature sheep using a fluoroscopically guided percutaneously delivered radiofrequency technique.
Effect of ischaemia on somatosensory evoked potentials in diabetic patients.
López-Alburquerque, T; García Miguel, A; Ruiz Ezquerro, J J; de Portugal Alvarez, J
1987-01-01
The nerve action potential at the elbow and somatosensory evoked potentials (SEPs) at the scalp were recorded over 30 minutes of tourniquet-induced limb ischaemia in 10 diabetic patients and 10 controls. According to the SEP changes, an increased resistance to nerve ischaemia in diabetic patients was observed. The pathways involved in SEP conduction are discussed. PMID:3585354
Spontaneous radial nerve palsy subsequent to non-traumatic neuroma.
Ebrahimpour, Adel; Nazerani, Shahram; Tavakoli Darestani, Reza; Khani, Salim
2013-09-01
Spontaneous radial palsy is a not rare finding in hand clinics. The anatomy of the radial nerve renders it prone to pressure paralysis as often called "Saturday night palsy". This problem is a transient nerve lesion and an acute one but the case presented here is very unusual in that it seems this entity can also occur as an acute on chronic situation with neuroma formation. A 61 year-old man presented with the chief complaint of inability to extend the wrist and the fingers of the left hand which began suddenly the night before admission, following a three-week history of pain, numbness and tingling sensation of the affected extremity. He had no history of trauma to the extremity. Electromyography revealed a severe conductive defect of the left radial nerve with significant axonal loss at the upper arm. Surgical exploration identified a neuroma of the radial nerve measuring 1.5 cm in length as the cause of the paralysis. The neuroma was removed and an end-to-end nerve coaption was performed. Complete recovery of the hand and finger extension was achieved in nine months.
Bach, M; Hoffmann, M B
2018-06-01
The data presented in this article are related to the research article entitled "Retinal conduction speed analysis reveals different origins of the P50 and N95 components of the (multifocal) pattern electroretinogram" (Bach et al., 2018) [1]. That analysis required the individual length data of the retinal nerve fibers (from ganglion cell body to optic nerve head, depending on the position of the ganglion cell body). Jansonius et al. (2009, 2012) [2,3] mathematically modeled the path morphology of the human retinal nerve fibers. We here present a working implementation with source code (for the free and open-source programming environment "R") of the Jansonius' formulas, including all errata. One file defines Jansonius et al.'s "phi" function. This function allows quantitative modelling of paths (and any measures derived from them) of the retinal nerve fibers. As a working demonstration, a second file contains a graph which plots samples of nerve fibers. The included R code runs in base R without the need of any additional packages.
Conductive Au nanowires regulated by silk fibroin nanofibers
NASA Astrophysics Data System (ADS)
Dong, Bo-Ju; Lu, Qiang
2014-03-01
Conductive Au-biopolymer composites have promising applications in tissue engineering such as nerve tissue regeneration. In this study, silk fibroin nanofibers were formed in aqueous solution by regulating silk self-assembly process and then used as template for Au nanowire fabrication. We performed the synthesis of Au seeds by repeating the seeding cycles for several times in order to increase the density of Au seeds on the nanofibers. After electroless plating, densely decorated Au seeds grew into irregularly shaped particles following silk nanofiber to fill the gaps between particles and finally form uniform continuous nanowires. The conductive property of the Au-silk fibroin nanowires was studied with current-voltage ( I-V) measurement. A typical ohmic behavior was observed, which highlighted their potential applications in nerve tissue regeneration.
Neurological Imaging in Acquired Cranial Nerve Palsy: Ophthalmologists vs. Neurologists.
Klein Hesselink, Tessa; Gutter, Mari; Polling, Jan Roelof
2017-09-01
Cranial nerve palsies often require neurological imaging by MRI. Guidelines on whether or not to utilize MRI have been absent or lack clarity. In daily practice, both neurologists and ophthalmologists treat patients with cranial nerve palsy and determine whether neuro-imaging is required. There appear to be differences in policy with respect to neuro-imaging. The question, which will be answered in this study, is the following: to what extent do differences in policy exist between ophthalmologists and neurologists regarding imaging by MRI of patients with acquired ocular cranial nerve palsy? PubMed database was searched for literature on acquired cranial nerve palsy and MRI scanning performed by ophthalmologists and neurologists. Case series published between 2000 and 2015 were included. The first author screened the literature on eligibility, profession of the authors, and conducted data abstraction. Ten case series were found eligible for analysis. A total of 889 cranial nerve palsies were described, 770 by ophthalmologists and 119 by neurologists. The age range of patients in all case series was 2 to 96 years of age. The oculomotor nerve was investigated in 162 patients, the trochlear nerve in 131 patients, and the abducens nerve in 486 patients. All neurologists (n=3) and 2 out of 7 investigated ophthalmologists recommended performing MRI scanning in every patient who presented with an ocular cranial nerve palsy, while 5 ophthalmologists (5/7) opted to triage patients for risk factors associated with cranial nerve palsies prior to ordering MRI imaging. When different groups of patients were viewed separately, it became apparent that almost all specialists agreed that every patient with a third nerve palsy and patients under 50 years of age should undergo MRI scanning. In patients with fourth nerve palsy, MRI scanning was not indicated. The neurologists in this study were more likely to perform MRI scanning in every patient presenting with ocular cranial nerve palsy. Ophthalmologists were more likely to determine risk factors associated with cranial nerve palsy, which they took into account when deciding whether or not to perform neurological imaging in patients aged more than 50 years or presenting with abducens nerve palsy.
Worley, John R; Brimmo, Olubusola; Nuelle, Clayton W; Cook, James L; Stannard, James P
2018-06-13
The purpose of this study was to determine incidence of concurrent peroneal nerve injury and to compare outcomes in patients with and without peroneal nerve injury after surgical treatment for multiligament knee injuries (MLKIs). A retrospective study of 357 MLKIs was conducted. Patients with two or more knee ligaments requiring surgical reconstruction were included. Mean follow-up was 35 months (0-117). Incidence of concurrent peroneal nerve injury was noted and patients with and without nerve injury were evaluated for outcomes. Concurrent peroneal nerve injury occurred in 68 patients (19%). In patients with nerve injury, 45 (73%) returned to full duty at work; 193 (81%) patients without nerve injury returned to full duty ( p = 0.06). In patients with nerve injury, 37 (60%) returned to their previous level of activity; 148 (62%) patients without nerve injury returned to their previous level of activity ( p = 0.41). At final follow-up, there were no significant differences in level of pain (mean visual analog scale 1.6 vs. 2; p = 0.17), Lysholm score (mean 88.6 vs. 88.8; p = 0.94), or International Knee Documentation Committee score (mean 46.2 vs. 47.8; p = 0.67) for patients with or without peroneal nerve injury, respectively. Postoperative range of motion (ROM) (mean 121 degrees) was significantly lower ( p = 0.02) for patients with nerve injury compared with patients without nerve injury (mean 127 degrees). Concurrent peroneal nerve injury occurred in 19% of patients in this large cohort suffering MLKIs. After knee reconstruction surgery, patients with concurrent peroneal nerve injuries had significantly lower knee ROM and trended toward a lower rate of return to work. However, outcomes with respect to activity level, pain, and function were not significantly different between the two groups. This study contributes to our understanding of patient outcomes in patients with concurrent MLKI and peroneal nerve injury, with a focus on the patient's ability to return to work and sporting activity. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
A randomized, controlled trial of magnetic therapy for carpal tunnel syndrome.
Baute, Vanessa; Keskinyan, Vahakn S; Sweeney, Erica R; Bowden, Kayla D; Gordon, Allison; Hutchens, Janet; Cartwright, Michael S
2018-03-07
Magnet therapy has been proposed as a treatment for neurologic conditions. In this this trial we assessed the feasibility and efficacy of a magnet inserted into a wristband for carpal tunnel syndrome (CTS). Twenty-two patients with mild to moderate CTS were randomized to wear a high-dose or low-dose "sham" magnetic wristband for 6 weeks. The primary outcome was the Symptom Severity Scale (SSS) of the Boston Carpal Tunnel Questionnaire. Secondary measures were nerve conduction studies (NCS), median nerve ultrasound, and compliance. Compliance for both groups was >90%. Improvements in the mean SSS, NCS, and median nerve ultrasound did not reach statistical significance. Magnet therapy via wristband is well-tolerated. Further investigations in larger populations are needed to determine efficacy. Muscle Nerve, 2018. © 2018 Wiley Periodicals, Inc.
BEA Discoveries 2010: BEA beyond the Buzz
ERIC Educational Resources Information Center
Fox, Bette-Lee; Heilbrun, Margaret; Hoffert, Barbara; Katterjohn, Anna; Kuzyk, Raya; McCormack, Heather; Rogers, Michael; Williams, Wilda
2010-01-01
With the exhibits at New York's Jacob K. Javits Convention Center open just two days, the show floor at this year's BEA was a real free-for-all, with lots of traffic from the moment the doors opened on Wednesday, May 26. But for LJ's review editors, it was worth enduring stubbed toes and rattled nerves to find fresh and interesting titles. In this…
Fabrication and characterization of conductive anodic aluminum oxide substrates
NASA Astrophysics Data System (ADS)
Altuntas, Sevde; Buyukserin, Fatih
2014-11-01
Biomaterials that allow the utilization of electrical, chemical and topographic cues for improved neuron-material interaction and neural regeneration hold great promise for nerve tissue engineering applications. The nature of anodic aluminum oxide (AAO) membranes intrinsically provides delicate control over topographic and chemical cues for enhanced cell interaction; however their use in nerve regeneration is still very limited. Herein, we report the fabrication and characterization of conductive AAO (CAAO) surfaces for the ultimate goal of integrating electrical cues for improved nerve tissue behavior on the nanoporous substrate material. Parafilm was used as a protecting polymer film, for the first time, in order to obtain large area (50 cm2) free-standing AAO membranes. Carbon (C) was then deposited on the AAO surface via sputtering. Morphological characterization of the CAAO surfaces revealed that the pores remain open after the deposition process. The presence of C on the material surface and inside the nanopores was confirmed by XPS and EDX studies. Furthermore, I-V curves of the surface were used to extract surface resistance values and conductive AFM demonstrated that current signals can only be achieved where conductive C layer is present. Finally, novel nanoporous C films with controllable pore diameters and one dimensional (1-D) C nanostructures were obtained by the dissolution of the template AAO substrate.
Pathak, Sachin; Mishra, Nitin; Rastogi, Madhur Kant; Sharma, Shalini
2014-05-01
Removal of impacted third molar is a procedure that is often associated with post-operative complications. The rate of complications is somewhat high because of its proximity to the vital structures. Inferior alveolar nerve paresthesia is one of the common complications of impacted their molar surgery. This is due to intimate relationship between roots of mandibular third molar and inferior alveolar canal. To access the proximity of inferior alveolar canal to third molar many diagnostic methods are suggested but in conventional radiography orthopantamogram is considered as the best. There are many findings onorthopantamogram that are suggestive of close proximity of nerve to the canal. In this study authors reviewed seven radiographic findings related to proximity of roots to the inferior alveolar nerve as seen on orthopantamogram and try to find a relationship between these radiographic variables and presence of post-operative paresthesia. The study containd 100 impacted third molars need to be removed. Presence of radiographic findings on orthopantamogram were noted and analyzed, to find a relationship with occurrence of post-operative inferior alveolar nerve paresthesia. This study comprises of 100 impacted third molar teeth indicated for extraction. Cases were randomly selected from the patients, needs to undergo extraction of impacted mandibular third molar. After extraction cases were evaluated for occurrence of inferior alveolar nerve paresthesia. Stastical Analyisis: Data was transferred to SPss 21 software for frequency calculation, and two tailed p-values were obtained betweens these variables and post-operative paresthesia, by applying Fischer's exact test (GRAPH PAD SOFTWARE). Out of seven, four radiological findings that are grooving of roots, hooked roots, bifid roots and obliteration of white line are significantly related to post-operative paresthesia while bending of canal, narrow canal and darkening of tooth roots over the canal are not significantly associated with post-operative morbidity of facial nerve.
Wang, Xiandi; Wang, Hongli; Sun, Chi; Zhou, Shuyi; Meng, Tao; Lv, Feizhou; Ma, Xiaosheng; Xia, Xinlei; Jiang, Jianyuan
2018-04-26
Previous studies have indicated that decreased fractional anisotropy (FA) values on diffusion tensor imaging (DTI) are well correlated with the symptoms of nerve root compression. The aim of our study is to determine primary radiological parameters associated with decreased FA values in patients with lumbar spinal stenosis involving single L5 nerve root. Patients confirmed with single L5 nerve root compression by transforaminal nerve root blocks were included in this study. FA values of L5 nerve roots on both symptomatic and asymptomatic side were obtained. Conventional radiological parameters, such as disc height, degenerative scoliosis, dural sac cross-sectional area (DSCSA), foraminal height (FH), hypertrophic facet joint degeneration (HFJD), sagittal rotation (SR), sedimentation sign, sagittal translation and traction spur were measured. Correlation and regression analyses were performed between the radiological parameters and FA values of the symptomatic L5 nerve roots. A predictive regression equation was established. Twenty-one patients were included in this study. FA values were significantly lower at the symptomatic side comparing to the asymptomatic side (0.263 ± 0.069 vs. 0.334 ± 0.080, P = 0.038). DSCSA, FH, HFJD, and SR were significantly correlated with the decreased FA values, with r = 0.518, 0.443, 0.472 and - 0.910, respectively (P < 0.05). DSCSA and SR were found to be the primary radiological parameters related to the decreased FA values, and the regression equation is FA = - 0.012 × SR + 0.002 × DSCSA. DSCSA and SR were primary contributors to decreased FA values in LSS patients involving single L5 nerve root, indicating that central canal decompression and segmental stability should be the first considerations in preoperative planning of these patients. These slides can be retrieved under Electronic Supplementary Material.
Chui, Jason; Murkin, John M; Drosdowech, Darren
2018-05-21
Peripheral nerve injury is a potentially devastating complication after total shoulder arthroplasty (TSA) surgery. This pilot study aimed to assess the feasibility of using an automated somatosensory evoked potential (SSEP) device to provide a timely alert/intervention to minimize intraoperative nerve insults during TSA surgery. A prospective, single-arm, observational study was conducted in a single university hospital. The attending anesthesiologist monitored the study participants using the EPAD automated SSEP device and an intervention was made if there was an alert during TSA surgery. The median, radial, and ulnar nerve SSEP on the operative arm, as well as the median nerve SSEP of the nonoperative arm were monitored for each patient. All patients were evaluated for postoperative neurological deficits 6 weeks postoperatively. In total, 21 patients were consented and were successfully monitored. In total, 4 (19%) patients developed intraoperative abnormal SSEP signal changes in the operative arm, in which 3 were reversible and 1 was irreversible till the end of surgery. Median and radial nerves were mostly involved (3/4 patients). The mean cumulative duration of nerve insult (abnormal SSEP) was 21.7±26.2 minutes. Univariate analysis did not identify predictor of intraoperative nerve insults. No patients demonstrated postoperative peripheral neuropathy at 6 weeks. A high incidence (19%) of intraoperative nerve insult was observed in this study demonstrating the feasibility of using an automated SSEP device to provide a timely alert and enable an intervention in order to minimize peripheral nerve injury during TSA. Further randomized studies are warranted.
Sun, Rui-Di; Fu, Bing; Jiang, Jun
2017-05-01
To investigate the role of short-latency somatosensory evoked potential (SSEP) in the diagnosis of chronic inflammatory demyelinating polyneuropathy (CIDP). A total of 48 children with a confirmed or suspected CIDP and 40 healthy children were enrolled. Nerve electrophysiological examination and/or SSEP examination was performed (the children in the healthy control group only underwent SSEP examination). Four-lead electromyography was used for nerve electrophysiological examination, including at least 4 motor nerves and 2 sensory nerves. N6 (elbow potential), N13 (cervical cord potential), and N20 (cortex potential) of the median nerve and N8 (popliteal fossa potential), N22 (lumbar cord potential), and P39 (cortex potential) of the tibial nerve were observed by SSEP examination. Among the 48 children with CIDP, 35 had demyelination in both motor and sensory nerves, 8 had demyelination in sensory nerves, and 5 had axonal degeneration. SSEP examination showed that 7 had conduction abnormality in the trunk of the brachial plexus and/or the posterior root and 33 had damage in the lumbosacral plexus and/or the posterior root. The 40 children with abnormal findings of SSEP examination included 8 children with affected sensory nerves and 5 children with secondary axonal degeneration who did not meet the electrophysiological diagnostic criteria for CIDP. Compared with the healthy control group, the CIDP group had significantly prolonged latency periods of N13 and N22 (P<0.05). SSEP can be used for the auxiliary diagnosis of CIDP, especially in CIDP children with affected sensory nerves or secondary axonal degeneration.
Chen, Ming-Hong; Chen, Pei-Ru; Chen, Mei-Hsiu; Hsieh, Sung-Tsang; Huang, Jing-Shan; Lin, Feng-Huei
2006-04-01
In order to modulate the mechanical properties of gelatin, we previously developed a biodegradable composite composed by tricalcium phosphate and glutaraldehyde crosslinking gelatin (GTG) feasible for surgical manipulation. In this study, we evaluated the in vivo applications of GTG conduit for peripheral nerve repair. The effect of sciatic nerve reconstruction was compared between resorbable permeable GTG conduits and durable impermeable silicone tubes. Traditional methods of assessing nerve recovery following peripheral nerve repair including histomorphometric and electrophysiologic features were conducted in our study. In addition, autotomy score and sciatic function index (SFI) in walking tract analysis were used as additional parameters for assessing the return of nerve function. Twenty-four weeks after sciatic nerve repair, the GTG conduits were harvested. Microscopically, regeneration of nerves was observed in the cross-section at the mid portion of all implanted GTG conduits. The cross-sectional area of regenerated nerve of the GTG group was significant larger than that of the silicone group. In the compound muscle action potentials (CMAP), the mean recovery index of CMAP amplitude was 0.24 +/- 0.02 for the silicone group, 0.41 +/- 0.07 for the GTG group. The mean SFI increased with time in the GTG group during the evaluation period until 24 weeks. Walking tract analysis showed a higher SFI score in the GTG group at both 12 and 24 weeks. The difference reached a significant level at 24 weeks. Thus, the histomorphometric, electrophysiologic, and functional assessments demonstrate that GTG can be a candidate for peripheral nerve repair.
Nerve growth factor released from a novel PLGA nerve conduit can improve axon growth
NASA Astrophysics Data System (ADS)
Lin, Keng-Min; Shea, Jill; Gale, Bruce K.; Sant, Himanshu; Larrabee, Patti; Agarwal, Jay
2016-04-01
Nerve injury can occur due to penetrating wounds, compression, traumatic stretch, and cold exposure. Despite prompt repair, outcomes are dismal. In an attempt to help resolve this challenge, in this work, a poly-lactic-co-glycolic acid (PLGA) nerve conduit with associated biodegradable drug reservoir was designed, fabricated, and tested. Unlike current nerve conduits, this device is capable of fitting various clinical scenarios by delivering different drugs without reengineering the whole system. To demonstrate the potential of this device for nerve repair, a series of experiments were performed using nerve growth factor (NGF). First, an NGF dosage curve was developed to determine the minimum NGF concentration for optimal axonal outgrowth on chick dorsal root ganglia (DRG) cells. Next, PLGA devices loaded with NGF were evaluated for sustained drug release and axon growth enhancement with the released drug. A 20 d in vitro release test was conducted and the nerve conduit showed the ability to meet and maintain the minimum NGF requirement determined previously. Bioactivity assays of the released NGF showed that drug released from the device between the 15th and 20th day could still promote axon growth (76.6-95.7 μm) in chick DRG cells, which is in the range of maximum growth. These novel drug delivery conduits show the ability to deliver NGF at a dosage that efficiently promotes ex vivo axon growth and have the potential for in vivo application to help bridge peripheral nerve gaps.
Klein, Amanda H; Vyshnevska, Alina; Hartke, Timothy V; De Col, Roberto; Mankowski, Joseph L; Turnquist, Brian; Bosmans, Frank; Reeh, Peter W; Schmelz, Martin; Carr, Richard W; Ringkamp, Matthias
2017-05-17
Voltage-gated sodium (Na V ) channels are responsible for the initiation and conduction of action potentials within primary afferents. The nine Na V channel isoforms recognized in mammals are often functionally divided into tetrodotoxin (TTX)-sensitive (TTX-s) channels (Na V 1.1-Na V 1.4, Na V 1.6-Na V 1.7) that are blocked by nanomolar concentrations and TTX-resistant (TTX-r) channels (Na V 1.8 and Na V 1.9) inhibited by millimolar concentrations, with Na V 1.5 having an intermediate toxin sensitivity. For small-diameter primary afferent neurons, it is unclear to what extent different Na V channel isoforms are distributed along the peripheral and central branches of their bifurcated axons. To determine the relative contribution of TTX-s and TTX-r channels to action potential conduction in different axonal compartments, we investigated the effects of TTX on C-fiber-mediated compound action potentials (C-CAPs) of proximal and distal peripheral nerve segments and dorsal roots from mice and pigtail monkeys ( Macaca nemestrina ). In the dorsal roots and proximal peripheral nerves of mice and nonhuman primates, TTX reduced the C-CAP amplitude to 16% of the baseline. In contrast, >30% of the C-CAP was resistant to TTX in distal peripheral branches of monkeys and WT and Na V 1.9 -/- mice. In nerves from Na V 1.8 -/- mice, TTX-r C-CAPs could not be detected. These data indicate that Na V 1.8 is the primary isoform underlying TTX-r conduction in distal axons of somatosensory C-fibers. Furthermore, there is a differential spatial distribution of Na V 1.8 within C-fiber axons, being functionally more prominent in the most distal axons and terminal regions. The enrichment of Na V 1.8 in distal axons may provide a useful target in the treatment of pain of peripheral origin. SIGNIFICANCE STATEMENT It is unclear whether individual sodium channel isoforms exert differential roles in action potential conduction along the axonal membrane of nociceptive, unmyelinated peripheral nerve fibers, but clarifying the role of sodium channel subtypes in different axonal segments may be useful for the development of novel analgesic strategies. Here, we provide evidence from mice and nonhuman primates that a substantial portion of the C-fiber compound action potential in distal peripheral nerves, but not proximal nerves or dorsal roots, is resistant to tetrodotoxin and that, in mice, this effect is mediated solely by voltage-gated sodium channel 1.8 (Na V 1.8). The functional prominence of Na V 1.8 within the axonal compartment immediately proximal to its termination may affect strategies targeting pain of peripheral origin. Copyright © 2017 the authors 0270-6474/17/375205-11$15.00/0.
Long- and Short-Term Health Effects of Pesticide Exposure: A Cohort Study from China
Li, Yifan; Zhang, Chao; Yin, Yanhong; Chen, Zhaohui; Jin, Yanhong; Cai, Jinyang; Cui, Fang
2015-01-01
Pesticides are extensively used by farmers in China. However, the effects of pesticides on farmers’ health have not yet been systematically studied. This study evaluated the effects of pesticides exposure on hematological and neurological indicators over 3 years and 10 days respectively. A cohort of 246 farmers was randomly selected from 3 provinces (Guangdong, Jiangxi, and Hebei) in China. Two rounds of health investigations, including blood tests and neurological examinations, were conducted by medical doctors before and after the crop season in 2012. The data on pesticide use in 2009–2011 were collected retrospectively via face-to-face interviews and the 2012 data were collected from personal records maintained by participants prospectively. Ordinary least square (OLS), Probit, and fixed effect models were used to evaluate the relationship between pesticides exposure frequency and the health indicators. Long-term pesticide exposure was found to be associated with increased abnormality of nerve conductions, especially in sensory nerves. It also affected a wide spectrum of health indicators based on blood tests and decreased the tibial nerve compound muscle action potential amplitudes. Short-term health effects included alterations in complete blood count, hepatic and renal functions, and nerve conduction velocities and amplitudes. However, these effects could not be detected after 3 days following pesticide exposure. Overall, our results demonstrate that pesticide exposure adversely affects blood cells, the liver, and the peripheral nervous system. Future studies are needed to elucidate the specific effects of each pesticide and the mechanisms of these effects. PMID:26042669
Longhurst, John C.
2013-01-01
Thinly myelinated Aδ-fiber and unmyelinated C-fiber cardiac sympathetic (spinal) sensory nerve fibers are activated during myocardial ischemia to transmit the sensation of angina pectoris. Although recent observations showed that myocardial ischemia increases the concentrations of opioid peptides and that the stimulation of peripheral opioid receptors inhibits chemically induced visceral and somatic nociception, the role of opioids in cardiac spinal afferent signaling during myocardial ischemia has not been studied. The present study tested the hypothesis that peripheral opioid receptors modulate cardiac spinal afferent nerve activity during myocardial ischemia by suppressing the responses of cardiac afferent nerve to ischemic mediators like bradykinin and extracellular ATP. The nerve activity of single unit cardiac afferents was recorded from the left sympathetic chain (T2–T5) in anesthetized cats. Forty-three ischemically sensitive afferent nerves (conduction velocity: 0.32–3.90 m/s) with receptive fields in the left and right ventricles were identified. The responses of these afferent nerves to repeat ischemia or ischemic mediators were further studied in the following protocols. First, epicardial administration of naloxone (8 μmol), a nonselective opioid receptor antagonist, enhanced the responses of eight cardiac afferent nerves to recurrent myocardial ischemia by 62%, whereas epicardial application of vehicle (PBS) did not alter the responses of seven other cardiac afferent nerves to ischemia. Second, naloxone applied to the epicardial surface facilitated the responses of seven cardiac afferent nerves to epicardial ATP by 76%. Third, administration of naloxone enhanced the responses of seven other afferent nerves to bradykinin by 85%. In contrast, in the absence of naloxone, cardiac afferent nerves consistently responded to repeated application of ATP (n = 7) or bradykinin (n = 7). These data suggest that peripheral opioid peptides suppress the responses of cardiac sympathetic afferent nerves to myocardial ischemia and ischemic mediators like ATP and bradykinin. PMID:23645463
Is distal motor and/or sensory demyelination a distinctive feature of anti-MAG neuropathy?
Lozeron, Pierre; Ribrag, Vincent; Adams, David; Brisset, Marion; Vignon, Marguerite; Baron, Marine; Malphettes, Marion; Theaudin, Marie; Arnulf, Bertrand; Kubis, Nathalie
2016-09-01
To report the frequency of the different patterns of sensory and motor electrophysiological demyelination distribution in patients with anti-MAG neuropathy in comparison with patients with IgM neuropathy without MAG reactivity (IgM-NP). Thirty-five anti-MAG patients at early disease stage (20.1 months) were compared to 23 patients with IgM-NP; 21 CIDP patients and 13 patients with CMT1a neuropathy were used as gold standard neuropathies with multifocal and homogeneous demyelination, respectively. In all groups, standard motor and sensory electrophysiological parameters, terminal latency index and modified F ratio were investigated. Motor electrophysiological demyelination was divided in four profiles: distal, homogeneous, proximal, and proximo-distal. Distal sensory and sensorimotor demyelination were evaluated. Anti-MAG neuropathy is a demyelinating neuropathy in 91 % of cases. In the upper limbs, reduced TLI is more frequent in anti-MAG neuropathy, compared to IgM-NP. But, predominant distal demyelination of the median nerve is encountered in only 43 % of anti-MAG neuropathy and is also common in IgM-NP (35 %). Homogeneous demyelination was the second most frequent pattern (31 %). Concordance of electrophysiological profiles across motor nerves trunks is low and median nerve is the main site of distal motor conduction slowing. Reduced sensory conduction velocities occurs in 14 % of patients without evidence of predominant distal slowing. Simultaneous sensory and motor distal slowing was more common in the median nerve of anti-MAG neuropathy than IgM-NP. Electrophysiological distal motor demyelination and sensory demyelination are not a distinctive feature of anti-MAG reactivity. In anti-MAG neuropathy it is mainly found in the median nerve suggesting a frequent nerve compression at wrist.
Diniz, Lúcio Ricardo Leite; Portella, Viviane Gomes; da Silva Alves, Kerly Shamira; Araújo, Pâmella Cristina da Costa; de Albuquerque Júnior, Ricardo Luiz Cavalcanti; Cavalcante de Albuquerque, Aline Alice; Coelho-de-Souza, Andrelina Noronha; Leal-Cardoso, José Henrique
2018-01-01
Background Nonspecific and delayed diagnosis of neurologic damage contributes to the development of neuropathies in patients with severe sepsis. The present study assessed the electrophysiologic parameters related to the excitability and conductibility of sciatic and vagus nerves during early stages of sepsis. Materials and methods Twenty-four hours after sepsis induced by cecal ligation and puncture (CLP) model, sciatic and vagus nerves of septic (CLP group) and control (sham group) rats were removed, and selected electric stimulations were applied to measure the parameters of the first and second components of the compound action potential. The first component originated from fibers with motor and sensory functions (Types Aα and Aβ fibers) with a large conduction velocity (70–120 m/s), and the second component originated from fibers (Type Aγ) with sensorial function. To evaluate the presence of sensorial alterations, the sensitivity to non-noxious mechanical stimuli was measured by using the von Frey test. Hematoxylin and eosin staining of the nerves was performed. Results We observed an increase of rheobase followed by a decrease in the first component amplitude and a higher paw withdrawal threshold in response to the application of von Frey filaments in sciatic nerves from the CLP group compared to the sham group. Differently, a decrease in rheobase and an increase in the first component amplitude of vagal C fibers from CLP group were registered. No significant morphologic alteration was observed. Conclusion Our data showed that the electrophysiologic alterations in peripheral nerves vary with the fiber type and might be identified in the first 24 h of sepsis, before clinical signs of neuromuscular disorders. PMID:29731661
Effects of the choice of reference on the selectivity of a multi-contact nerve cuff electrode.
Koh, Ryan G L; Zariffa, Jose
2016-08-01
Tripolar referencing is typically used in nerve cuff electrode recordings due to its ability to maximize the signal-to-noise ratio of contacts at the centre, but this may not be the optimal choice for a multi-contact nerve cuff consisting of contacts in off-centre rings. We conducted a simulation study to compare the effects of 3 different reference types on the recording selectivity of a multi-contact nerve cuff: the tripolar reference (TPR), common average reference (CAR), and multiple tripolar references based on consecutive groups of 3 rings (cTPR). For this purpose, we introduce a novel measure called the contact information metric (CIM). Selectivity was tested in 2 noise settings, one in which white Gaussian noise was added inside the nerve cuff electrode and the other in which electromyogram (EMG) noise was added outside the nerve cuff electrode. The mean CIMs values calculated for the best 8 contacts were 3.42±6.25, 2.70±3.37, and 3.65±1.90 for the TPR, the CAR and the cTPR, respectively, in the case of EMG noise added outside the nerve cuff electrode. This study shows that the use of cTPR reference is the optimal choice for selectivity when using a multi-contact nerve cuff electrode which contains off-centre rings.
Combinatorial treatments enhance recovery following facial nerve crush.
Sharma, Nijee; Moeller, Carl W; Marzo, Sam J; Jones, Kathryn J; Foecking, Eileen M
2010-08-01
To investigate the effects of various combinatorial treatments, consisting of a tapering dose of prednisone (P), a brief period of nerve electrical stimulation (ES), and systemic testosterone propionate (TP) on improving functional recovery following an intratemporal facial nerve crush injury. Prospective, controlled animal study. After a right intratemporal facial nerve crush, adult male Sprague-Dawley rats were divided into the following eight treatment groups: 1) no treatment, 2) P only, 3) ES only, 4) ES + P, 5) TP only, 6) TP + P, 7) ES + TP, and 8) ES + TP + P. For each group n = 4-8. Recovery of the eyeblink reflex and vibrissae orientation and movement were assessed. Changes in peak amplitude and latency of evoked response, in response to facial nerve stimulation, was also recorded weekly. : Brief ES of the proximal nerve stump most effectively accelerated the initiation of functional recovery. Also, ES or TP treatments enhanced recovery of some functional parameters more than P treatment. When administered alone, none of the three treatments improved recovery of complete facial function. Only the combinatorial treatment of ES + TP, regardless of the presence of P, accelerated complete functional recovery and return of normal motor nerve conduction. Our findings suggest that a combinatorial treatment strategy of using brief ES and TP together promises to be an effective therapeutic intervention for promoting regeneration following facial nerve injury. Administration of P neither augments nor hinders recovery.
Zhang, Mingxing; Zhang, Ye; Bian, Yuhong; Fu, Hui; Xu, Ying; Guo, Yi
2018-06-01
Recently, application of electroacupuncture (EA) to stimulate nerve regeneration has become a mainstream treatment in clinical rehabilitation and related basic research, but the efficacy of long-term stimulation has not been confirmed. To evaluate the influence of long term EA on peripheral nerve injury (PNI) from multiple angles. Twenty-four rats were divided into three groups: control, PNI and PNI+EA. In the latter two groups, PNI was modelled by transection followed by re-anastomosis of thesciatic nerve. In the PNI+EA group only,EA was delivered using a discontinuous wave with frequency 5 Hz, pulse width 2 ms, and intensity approximately 2 mA, until the affected limb was observed to twitch slightly. The treatment was given for 15 min each time, six times a week (continuously for 6 days followed by a 1-day break) for a total of 8 weeks. The effects of EA on anastomotic sciatic nerve regeneration were evaluated using the sciatic function index (SFI), mechanical withdrawal thresholds, thermo-nociceptive thresholds, conduction velocity of the sciatic nerve and bilateral gastrocnemius wet weight. From weeks 2 to 4 after modelling, the SFI recovery rate in the PNI+EA group was faster than that in the PNI group. In week 4, the SFI of the PNI+EA group was significantly higher than that of the PNI group (p<0.05). However, a significant effect of EA was no longer evident from weeks 5 to 8. There was no effect of acupuncture on anti-amyotrophy and conduction velocity of the sciatic nerve at 8 weeks after modelling. EA did not shorten the paw withdrawal threshold time, but appeared to alleviate thermo-nociceptive sensitivity. Long term repeated stimulation of the same site with EA does not appear to be conducive to the functional recovery of an injured sciatic nerve in rats. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Roy, Kanchan Sinha; Purohit, Ajay Kumar; Chandra, Buddhadeb; Goud, D Raghavender; Pardasani, Deepak; Dubey, Devendra Kumar
2018-06-05
Extraction and identification of lethal nerve agents and their markers in complex organic background have a prime importance from the forensic and verification viewpoint of the Chemical Weapons Convention (CWC). Liquid-liquid extraction with acetonitrile and commercially available solid phase silica cartridges are extensively used for this purpose. Silica cartridges exhibit limited applicability for relatively polar analytes, and acetonitrile extraction shows limited efficacy toward relatively nonpolar analytes. The present study describes the synthesis of polymeric sorbents with tunable surface polarity, their application as a solid-phase extraction (SPE) material against nerve agents and their polar as well as nonpolar markers from nonpolar organic matrices. In comparison with the acetonitrile extraction and commercial silica cartridges, the new sorbent showed better extraction efficiency toward analytes of varying polarity. The extraction parameters were optimized for the proposed method, which included ethyl acetate as an extraction solvent and n-hexane as a washing solvent. Under optimized conditions, method linearity ranged from 0.10 to 10 μg mL -1 ( r 2 = 0.9327-0.9988) for organophosphorus esters and 0.05-20 μg mL -1 ( r 2 = 0.9976-0.9991) for nerve agents. Limits of detection (S:N = 3:1) in the SIM mode were found in the range of 0.03-0.075 μg mL -1 for organophosphorus esters and 0.015-0.025 μg mL -1 for nerve agents. Limits of quantification (S:N = 10:1) were found in the range of 0.100-0.25 μg mL -1 for organophosphorus esters and 0.05-0.100 μg mL -1 for nerve agents in the SIM mode. The recoveries of the nerve agents and their markers ranged from 90.0 to 98.0% and 75.0 to 95.0% respectively. The repeatability and reproducibility (with relative standard deviations (RSDs) %) for organophosphorus esters were found in the range of 1.35-8.61% and 2.30-9.25% respectively. For nerve agents, the repeatability range from 1.00 to 7.75% and reproducibility were found in the range of 2.17-6.90%.
Journal of Special Operations Medicine. Volume 2, Edition 1, Winter 2002
2002-01-01
regarding clean surgi- cal procedures that an antibiotic treatment regime must be based upon the expected pathogens, appro- priate pharmacokinetic properties...conduction apparatus toDiagram of ear Auricle Epitympanic recess Malleus (head) Incus Crura of stapes Tegmen tympani Cochlear nerve Vesibular nerve Facial...Prominence of lateral semicircular canal Scala vestibuli Cochlear duct containing spiral organ (of Corti) Scala tympaniAuditory (Eustachian) tube Round
Serra-Guillen, C; Hueso, L; Nagore, E; Vila, M; Llombart, B; Requena Caballero, C; Botella-Estrada, R; Sanmartin, O; Alfaro-Rubio, A; Guillen, C
2009-08-01
Photodynamic therapy (PDT) is an effective treatment for actinic keratoses, Bowen's disease and basal cell carcinoma. The main drawback of PDT is pain during application. To compare the efficacy of supratrochlear and supraorbital nerve block with cold air analgesia to control the pain experienced during PDT. A controlled open clinical trial was conducted in 34 patients having multiple actinic keratoses in the frontal region treated with PDT. On one side of the frontal region the supratrochlear and supraorbital nerves were blocked, while on the other side cold air was used as the method of analgesia. Pain was recorded on a visual analogue scale after treatment. Thirty-one of 34 patients reported less pain in the zone treated with nerve block. This difference was statistically significant. Nerve block is superior to cold air and is an easy, safe, effective means of controlling the pain associated with PDT.