Sample records for conventional sampling techniques

  1. The effect of a cannula milk sampling technique on the microbiological diagnosis of bovine mastitis.

    PubMed

    Friman, M; Hiitiö, H; Niemi, M; Holopainen, J; Pyörälä, S; Simojoki, H

    2017-08-01

    Two methods of collecting milk samples from mastitic bovine mammary quarters were compared. Samples were taken in a consistent order in which standard aseptic technique sampling was done first, followed by insertion of a sterile cannula through the teat canal and collection of a second sample. Microbiological results of those two sampling techniques were compared. Milk samples were analysed using multiplex real-time polymerase chain reaction (PCR). The cannula technique produced a reduced number of microbial species or groups of species per sample compared with conventional sampling. Staphylococcus spp. were the most common species identified and were detected more often during conventional sampling than with cannula sampling. Staphylococcus spp. identified in milk samples could also have originated from the teat canal without being present in the milk. The number of samples positive for Trueperella pyogenes or yeasts in the conventional samples was twice as high as in the cannula samples, indicating that the presence of Trueperella pyogenes and yeast species should not necessarily be interpreted as being the causative agents of bovine intra-mammary infections (IMI). Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. 40Ar/39Ar technique of KAr dating: a comparison with the conventional technique

    USGS Publications Warehouse

    Brent, Dalrymple G.; Lanphere, M.A.

    1971-01-01

    K-Ar ages have been determined by the 40Ar/39Ar total fusion technique on 19 terrestrial samples whose conventional K-Ar ages range from 3.4 my to nearly 1700 my. Sample materials included biotite, muscovite, sanidine, adularia, plagioclase, hornblende, actinolite, alunite, dacite, and basalt. For 18 samples there are no significant differences at the 95% confidence level between the KAr ages obtained by these two techniques; for one sample the difference is 4.3% and is statistically significant. For the neutron doses used in these experiments (???4 ?? 1018 nvt) it appears that corrections for interfering Ca- and K-derived Ar isotopes can be made without significant loss of precision for samples with K/Ca > 1 as young as about 5 ?? 105 yr, and for samples with K/Ca < 1 as young as about 107 yr. For younger samples the combination of large atmospheric Ar corrections and large corrections for Ca- and K-derived Ar may make the precision of the 40Ar/39Ar technique less than that of the conventional technique unless the irradiation parameters are adjusted to minimize these corrections. ?? 1971.

  3. Clinical application of microsampling versus conventional sampling techniques in the quantitative bioanalysis of antibiotics: a systematic review.

    PubMed

    Guerra Valero, Yarmarly C; Wallis, Steven C; Lipman, Jeffrey; Stove, Christophe; Roberts, Jason A; Parker, Suzanne L

    2018-03-01

    Conventional sampling techniques for clinical pharmacokinetic studies often require the removal of large blood volumes from patients. This can result in a physiological or emotional burden, particularly for neonates or pediatric patients. Antibiotic pharmacokinetic studies are typically performed on healthy adults or general ward patients. These may not account for alterations to a patient's pathophysiology and can lead to suboptimal treatment. Microsampling offers an important opportunity for clinical pharmacokinetic studies in vulnerable patient populations, where smaller sample volumes can be collected. This systematic review provides a description of currently available microsampling techniques and an overview of studies reporting the quantitation and validation of antibiotics using microsampling. A comparison of microsampling to conventional sampling in clinical studies is included.

  4. Clinical forensic sample collection techniques following consensual intercourse in volunteers - cervical canal brush compared to conventional swabs.

    PubMed

    Joki-Erkkilä, Minna; Tuomisto, Sari; Seppänen, Mervi; Huhtala, Heini; Ahola, Arja; Rainio, Juha; Karhunen, Pekka J

    2014-10-01

    The purpose of the research was to evaluate gynecological evidence collection techniques; the benefit of cervical canal brush sample compared to vaginal fornix and cervical swab samples and the time frame for detecting Y-chromosomal material QiAmp DNA Mini Kit(®) and Quantifiler Y Human Male DNA Quantification Kit(®) in adult volunteers following consensual intercourse. Eighty-four adult female volunteers following consensual intercourse were recruited for the study. By combining all sample collecting techniques, 81.0% of the volunteers were Y-DNA positive. Up to 60 h the conventional swab sampling techniques detected more Y-DNA positive samples when compared to the brush technique. However, after 60 h, the cervical canal brush sample technique showed its benefit by detecting 27.3% (6/22) of Y-DNA positive samples, which were Y-DNA negative in both conventional swab sampling techniques. By combining swab and brush techniques, 75% of the volunteers were still Y-DNA positive in 72-144 post-coital hours. The rate of measurable Y-DNA decreased approximately 3% per hour. Despite reported consensual intercourse, 6.8% (3/44) of volunteers were Y-DNA negative within 48 h. Y-DNA was not detected after 144 post-coital hours (6 days). In conclusion, the brush as a forensic evidence collection method may provide additional biological trace evidence from the cervical canal, although the best biological trace evidence collection can be obtained by combining all three sampling techniques. The time frame for gynecological forensic evidence sample collection should be considered to be at least a week if sexual violence is suspected. Copyright © 2014 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  5. Differentiating organic from conventional peppermints using chromatographic and flow-injection mass spectrometric (FIMS) fingerprints

    USDA-ARS?s Scientific Manuscript database

    High performance liquid chromatography (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were tested for their potential in differentiating organic and conventional peppermint samples. Ten organic and ten conventional peppermint samples were examined using HPLC-UV and FI...

  6. Effects of conventional welding and laser welding on the tensile strength, ultimate tensile strength and surface characteristics of two cobalt-chromium alloys: a comparative study.

    PubMed

    Madhan Kumar, Seenivasan; Sethumadhava, Jayesh Raghavendra; Anand Kumar, Vaidyanathan; Manita, Grover

    2012-06-01

    The purpose of this study was to evaluate the efficacy of laser welding and conventional welding on the tensile strength and ultimate tensile strength of the cobalt-chromium alloy. Samples were prepared with two commercially available cobalt-chromium alloys (Wironium plus and Diadur alloy). The samples were sectioned and the broken fragments were joined using Conventional and Laser welding techniques. The welded joints were subjected to tensile and ultimate tensile strength testing; and scanning electron microscope to evaluate the surface characteristics at the welded site. Both on laser welding as well as on conventional welding technique, Diadur alloy samples showed lesser values when tested for tensile and ultimate tensile strength when compared to Wironium alloy samples. Under the scanning electron microscope, the laser welded joints show uniform welding and continuous molt pool all over the surface with less porosity than the conventionally welded joints. Laser welding is an advantageous method of connecting or repairing cast metal prosthetic frameworks.

  7. FT-Raman study of dehydrogenation polymer (DHP) lignins

    Treesearch

    Umesh P. Agarwal; Noritsugu Terashima

    2003-01-01

    Compared to conventional Raman spectroscopy where samples are excited using visible light lasers, 1064 nm-excited FT-Raman technique has the single most important advantage that the sample-fluorescence is significantly suppressed for samples that are strongly fluorescent. DHPs are difficult to analyze in conventional Raman because small amounts of chromophores present...

  8. Machining and characterization of self-reinforced polymers

    NASA Astrophysics Data System (ADS)

    Deepa, A.; Padmanabhan, K.; Kuppan, P.

    2017-11-01

    This Paper focuses on obtaining the mechanical properties and the effect of the different machining techniques on self-reinforced composites sample and to derive the best machining method with remarkable properties. Each sample was tested by the Tensile and Flexural tests, fabricated using hot compaction test and those loads were calculated. These composites are machined using conventional methods because of lack of advanced machinery in most of the industries. The advanced non-conventional methods like Abrasive water jet machining were used. These machining techniques are used to get the better output for the composite materials with good mechanical properties compared to conventional methods. But the use of non-conventional methods causes the changes in the work piece, tool properties and more economical compared to the conventional methods. Finding out the best method ideal for the designing of these Self Reinforced Composites with and without defects and the use of Scanning Electron Microscope (SEM) analysis for the comparing the microstructure of the PP and PE samples concludes our process.

  9. Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: A comparative in vitro study.

    PubMed

    Ullattuthodi, Sujana; Cherian, Kandathil Phillip; Anandkumar, R; Nambiar, M Sreedevi

    2017-01-01

    This in vitro study seeks to evaluate and compare the marginal and internal fit of cobalt-chromium copings fabricated using the conventional and direct metal laser sintering (DMLS) techniques. A master model of a prepared molar tooth was made using cobalt-chromium alloy. Silicone impression of the master model was made and thirty standardized working models were then produced; twenty working models for conventional lost-wax technique and ten working models for DMLS technique. A total of twenty metal copings were fabricated using two different production techniques: conventional lost-wax method and DMLS; ten samples in each group. The conventional and DMLS copings were cemented to the working models using glass ionomer cement. Marginal gap of the copings were measured at predetermined four points. The die with the cemented copings are standardized-sectioned with a heavy duty lathe. Then, each sectioned samples were analyzed for the internal gap between the die and the metal coping using a metallurgical microscope. Digital photographs were taken at ×50 magnification and analyzed using measurement software. Statistical analysis was done by unpaired t -test and analysis of variance (ANOVA). The results of this study reveal that no significant difference was present in the marginal gap of conventional and DMLS copings ( P > 0.05) by means of ANOVA. The mean values of internal gap of DMLS copings were significantly greater than that of conventional copings ( P < 0.05). Within the limitations of this in vitro study, it was concluded that the internal fit of conventional copings was superior to that of the DMLS copings. Marginal fit of the copings fabricated by two different techniques had no significant difference.

  10. Comparison of specimen adequacy and smear quality in oral smears prepared by manual liquid-based cytology and conventional methods

    PubMed Central

    Shukla, Surabhi; Einstein, A; Shukla, Abhilasha; Mishra, Deepika

    2015-01-01

    Background: Liquid-based cytology (LBC), recommended in the mass screening of potentially malignant cervical and oral lesions, suffers from high cost owing to the use of expensive automated devices and materials. Considering the need for cost-effective LBC techniques, we evaluated the efficacy of an inexpensive manual LBC (MLBC) technique against conventional cytological technique in terms of specimen adequacy and smear quality of oral smears. Materials and Methods: Cytological samples were collected from 21 patients using a cytobrush device. After preparation of a conventional smear, the brush containing the remaining sample was immersed in the preservative vial. The preserved material was processed by an MLBC technique and subsequently, direct smears were made from the prepared cell button. Both conventional and MLBC smears were stained by routine Papanicolaou technique and evaluated by an independent observer for the thickness of the smear, cellular distribution, resolution/clarity of cells, cellular staining characteristics and the presence of unsatisfactory background/artifacts. Each parameter was graded as satisfactory; or satisfactory, but limited; or unsatisfactory. Chi-square test was used to compare the values obtained (significance set at P ≤ 0.05). Results: MLBC technique produced a significant number of satisfactory smears with regard to cell distribution, clarity/resolution, staining characteristics and background/artifacts compared to conventional methods. Conclusions: MLBC is a cost-effective cytological technique that may produce oral smears with excellent cytomorphology and longer storage life. PMID:26980958

  11. Comparison between mechanical freezer and conventional freezing using liquid nitrogen in normozoospermia.

    PubMed

    Rahana, A R; Ng, S P; Leong, C F; Rahimah, M D

    2011-10-01

    This study evaluated the effect of human semen cryopreservation using an ultra-low temperature technique with a mechanical freezer at -85°C as an alternative method to the conventional liquid nitrogen technique at -196°C. This was a prospective experimental study conducted in the Medically Assisted Conception unit, Department of Obstetrics and Gynaecology, National University Hospital, Malaysia from January 1, 2006 to April 30, 2007. All normozoospermic semen samples were included in the study. The concentration, motility and percentage of intact DNA of each semen sample were assessed before and after freezing and thawing on Days 7 and 30 post freezing. Sperm cryopreservation at -85°C was comparable to the conventional liquid nitrogen technique for a period of up to 30 days in a normozoospermic sample. There was no statistical difference in concentration (Day 7 p-value is 0.1, Day 30 p-value is 0.2), motility (Day 7 p-value is 0.9, Day 30 p-value is 0.5) and proportion of intact DNA (Day 7 p-value is 0.1, Day 30 p-value is 0.2) between the ultra-low temperature technique and conventional liquid nitrogen cryopreservation at Days 7 and 30 post thawing. This study clearly demonstrates that short-term storage of sperm at -85°C could be a viable alternative to conventional liquid nitrogen cryopreservation at -196°C due to their comparable post-thaw results.

  12. Effect of mechanical alloying synthesis process on the dielectric properties of (Bi{sub 0.5}Na{sub 0.5}){sub 0.94}Ba{sub 0.06}TiO{sub 3} piezoceramics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghazanfari, Mohammad Reza, E-mail: Ghazanfari.mr@gmail.com; Amini, Rasool; Shams, Seyyedeh Fatemeh

    Highlights: • MA samples show higher dielectric permittivity and Curie temperature. • In MA samples, dielectric loss is almost 27% less than conventional ones. • In MA samples, sintering time and temperature are lower than conventional ones. • In MA samples, particle morphology is more homogeneous conventional ones. • In MA samples, crystallite size is smaller conventional ones. - Abstract: In present work, in order to study the effects of synthesis techniques on dielectric properties, the BNBT lead-free piezoceramics with (Bi{sub 0.5}Na{sub 0.5}){sub 0.94}Ba{sub 0.06}TiO{sub 3} stoichiometry (called as BNBT6) were synthesized by mechanical alloying (MA) and conventional mixed oxidesmore » methods. The structural, microstructural, and dielectric properties were carried out by X-ray diffractometer (XRD), scanning electron microscope (SEM), and impedance analyzer LCR meter, respectively. Based on results, the density of MA samples is considerably higher than conventional samples owning to smaller particles size and more uniformity of particle shape of MA samples. Moreover, the dielectric properties of MA samples are comparatively improved in which the dielectric loss of these samples is almost 27% less than conventional ones. Furthermore, MA samples exhibit obviously higher dielectric permittivity and Curie temperature compared to the conventional samples.« less

  13. Work Sampling Study of an Engineering Professor during a Regular Contract Period

    ERIC Educational Resources Information Center

    Brink, Jan; McDonald, Dale B.

    2015-01-01

    Work sampling is a technique that has been employed in industry and fields such as healthcare for some time. It is a powerful technique, and an alternative to conventional stop watch time studies, used by industrial engineers to focus upon random work sampling observations. This study applies work sampling to the duties performed by an individual…

  14. Environmental scanning electron microscopy in cell biology.

    PubMed

    McGregor, J E; Staniewicz, L T L; Guthrie Neé Kirk, S E; Donald, A M

    2013-01-01

    Environmental scanning electron microscopy (ESEM) (1) is an imaging technique which allows hydrated, insulating samples to be imaged under an electron beam. The resolution afforded by this technique is higher than conventional optical microscopy but lower than conventional scanning electron microscopy (CSEM). The major advantage of the technique is the minimal sample preparation needed, making ESEM quick to use and the images less susceptible to the artifacts that the extensive sample preparation usually required for CSEM may introduce. Careful manipulation of both the humidity in the microscope chamber and the beam energy are nevertheless essential to prevent dehydration and beam damage artifacts. In some circumstances it is possible to image live cells in the ESEM (2).In the following sections we introduce the fundamental principles of ESEM imaging before presenting imaging protocols for plant epidermis, mammalian cells, and bacteria. In the first two cases samples are imaged using the secondary electron (topographic) signal, whereas a transmission technique is employed to image bacteria.

  15. Laser cleaning of steel for paint removal

    NASA Astrophysics Data System (ADS)

    Chen, G. X.; Kwee, T. J.; Tan, K. P.; Choo, Y. S.; Hong, M. H.

    2010-11-01

    Paint removal is an important part of steel processing for marine and offshore engineering. For centuries, a blasting techniques have been widely used for this surface preparation purpose. But conventional blasting always has intrinsic problems, such as noise, explosion risk, contaminant particles, vibration, and dust. In addition, processing wastes often cause environmental problems. In recent years, laser cleaning has attracted much research effort for its significant advantages, such as precise treatment, and high selectivity and flexibility in comparison with conventional cleaning techniques. In the present study, we use this environmentally friendly technique to overcome the problems of conventional blasting. Processed samples are examined with optical microscopes and other surface characterization tools. Experimental results show that laser cleaning can be a good alternative candidate to conventional blasting.

  16. Comparative Evaluation of Conventional and Accelerated Castings on Marginal Fit and Surface Roughness.

    PubMed

    Jadhav, Vivek Dattatray; Motwani, Bhagwan K; Shinde, Jitendra; Adhapure, Prasad

    2017-01-01

    The aim of this study was to evaluate the marginal fit and surface roughness of complete cast crowns made by a conventional and an accelerated casting technique. This study was divided into three parts. In Part I, the marginal fit of full metal crowns made by both casting techniques in the vertical direction was checked, in Part II, the fit of sectional metal crowns in the horizontal direction made by both casting techniques was checked, and in Part III, the surface roughness of disc-shaped metal plate specimens made by both casting techniques was checked. A conventional technique was compared with an accelerated technique. In Part I of the study, the marginal fit of the full metal crowns as well as in Part II, the horizontal fit of sectional metal crowns made by both casting techniques was determined, and in Part III, the surface roughness of castings made with the same techniques was compared. The results of the t -test and independent sample test do not indicate statistically significant differences in the marginal discrepancy detected between the two casting techniques. For the marginal discrepancy and surface roughness, crowns fabricated with the accelerated technique were significantly different from those fabricated with the conventional technique. Accelerated casting technique showed quite satisfactory results, but the conventional technique was superior in terms of marginal fit and surface roughness.

  17. Comparison Between Conventional and Automated Techniques for Blood Grouping and Crossmatching: Experience from a Tertiary Care Centre.

    PubMed

    Bhagwat, Swarupa Nikhil; Sharma, Jayashree H; Jose, Julie; Modi, Charusmita J

    2015-01-01

    The routine immunohematological tests can be performed by automated as well as manual techniques. These techniques have advantages and disadvantages inherent to them. The present study aims to compare the results of manual and automated techniques for blood grouping and crossmatching so as to validate the automated system effectively. A total of 1000 samples were subjected to blood grouping by the conventional tube technique (CTT) and the automated microplate LYRA system on Techno TwinStation. A total of 269 samples (multitransfused patients and multigravida females) were compared for 927 crossmatches by the CTT in indirect antiglobulin phase against the column agglutination technique (CAT) performed on Techno TwinStation. For blood grouping, the study showed a concordance in results for 942/1000 samples (94.2%), discordance for 4/1000 (0.4%) samples and uninterpretable result for 54/1000 samples (5.4%). On resolution, the uninterpretable results reduced to 49/1000 samples (4.9%) with 951/1000 samples (95.1%) showing concordant results. For crossmatching, the automated CAT showed concordant results in 887/927 (95.6%) and discordant results in 3/927 (0.32%) crossmatches as compared to the CTT. Total 37/927 (3.9%) crossmatches were not interpretable by the automated technique. The automated system shows a high concordance of results with CTT and hence can be brought into routine use. However, the high proportion of uninterpretable results emphasizes on the fact that proper training and standardization are needed prior to its use.

  18. RF Microalgal lipid content characterization

    PubMed Central

    Ahmad, Mahmoud Al; Al-Zuhair, Sulaiman; Taher, Hanifa; Hilal-Alnaqbi, Ali

    2014-01-01

    Most conventional techniques for the determination of microalgae lipid content are time consuming and in most cases are indirect and require excessive sample preparations. This work presents a new technique that utilizes radio frequency (RF) for rapid lipid quantification, without the need for sample preparation. Tests showed that a shift in the resonance frequency of a RF open-ended coaxial resonator and a gradual increase in its resonance magnitude may occur as the lipids content of microalgae cells increases. These response parameters can be then calibrated against actual cellular lipid contents and used for rapid determination of the cellular lipids. The average duration of lipid quantification using the proposed technique was of about 1 minute, which is significantly less than all other conventional techniques, and was achieved without the need for any time consuming treatment steps. PMID:24870372

  19. Evaluation of the marginal fit of metal copings fabricated on three different marginal designs using conventional and accelerated casting techniques: an in vitro study.

    PubMed

    Vaidya, Sharad; Parkash, Hari; Bhargava, Akshay; Gupta, Sharad

    2014-01-01

    Abundant resources and techniques have been used for complete coverage crown fabrication. Conventional investing and casting procedures for phosphate-bonded investments require a 2- to 4-h procedure before completion. Accelerated casting techniques have been used, but may not result in castings with matching marginal accuracy. The study measured the marginal gap and determined the clinical acceptability of single cast copings invested in a phosphate-bonded investment with the use of conventional and accelerated methods. One hundred and twenty cast coping samples were fabricated using conventional and accelerated methods, with three finish lines: Chamfer, shoulder and shoulder with bevel. Sixty copings were prepared with each technique. Each coping was examined with a stereomicroscope at four predetermined sites and measurements of marginal gaps were documented for each. A master chart was prepared for all the data and was analyzed using Statistical Package for the Social Sciences version. Evidence of marginal gap was then evaluated by t-test. Analysis of variance and Post-hoc analysis were used to compare two groups as well as to make comparisons between three subgroups . Measurements recorded showed no statistically significant difference between conventional and accelerated groups. Among the three marginal designs studied, shoulder with bevel showed the best marginal fit with conventional as well as accelerated casting techniques. Accelerated casting technique could be a vital alternative to the time-consuming conventional casting technique. The marginal fit between the two casting techniques showed no statistical difference.

  20. Poly (lactic-co-glycolic acid) particles prepared by microfluidics and conventional methods. Modulated particle size and rheology.

    PubMed

    Perez, Aurora; Hernández, Rebeca; Velasco, Diego; Voicu, Dan; Mijangos, Carmen

    2015-03-01

    Microfluidic techniques are expected to provide narrower particle size distribution than conventional methods for the preparation of poly (lactic-co-glycolic acid) (PLGA) microparticles. Besides, it is hypothesized that the particle size distribution of poly (lactic-co-glycolic acid) microparticles influences the settling behavior and rheological properties of its aqueous dispersions. For the preparation of PLGA particles, two different methods, microfluidic and conventional oil-in-water emulsification methods were employed. The particle size and particle size distribution of PLGA particles prepared by microfluidics were studied as a function of the flow rate of the organic phase while particles prepared by conventional methods were studied as a function of stirring rate. In order to study the stability and structural organization of colloidal dispersions, settling experiments and oscillatory rheological measurements were carried out on aqueous dispersions of PLGA particles with different particle size distributions. Microfluidics technique allowed the control of size and size distribution of the droplets formed in the process of emulsification. This resulted in a narrower particle size distribution for samples prepared by MF with respect to samples prepared by conventional methods. Polydisperse samples showed a larger tendency to aggregate, thus confirming the advantages of microfluidics over conventional methods, especially if biomedical applications are envisaged. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems.

    PubMed

    An, Jiwoo; Trujillo-Rodríguez, María J; Pino, Verónica; Anderson, Jared L

    2017-06-02

    The development of rapid, convenient, and high throughput sample preparation approaches such as liquid phase microextraction techniques have been continuously developed over the last decade. More recently, significant attention has been given to the replacement of conventional organic solvents used in liquid phase microextraction techniques in order to reduce toxic waste and to improve selectivity and/or extraction efficiency. With these objectives, non-conventional solvents have been explored in liquid phase microextraction and aqueous biphasic systems. The utilized non-conventional solvents include ionic liquids, magnetic ionic liquids, and deep eutectic solvents. They have been widely used as extraction solvents or additives in various liquid phase microextraction modes including dispersive liquid-liquid microextraction, single-drop microextraction, hollow fiber-liquid phase microextraction, as well as in aqueous biphasic systems. This review provides an overview into the use of non-conventional solvents in these microextraction techniques in the past 5 years (2012-2016). Analytical applications of the techniques are also discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Mass Spectrometric and Synchrotron Radiation based techniques for the identification and distribution of painting materials in samples from paints of Josep Maria Sert

    PubMed Central

    2012-01-01

    Background Establishing the distribution of materials in paintings and that of their degradation products by imaging techniques is fundamental to understand the painting technique and can improve our knowledge on the conservation status of the painting. The combined use of chromatographic-mass spectrometric techniques, such as GC/MS or Py/GC/MS, and the chemical mapping of functional groups by imaging SR FTIR in transmission mode on thin sections and SR XRD line scans will be presented as a suitable approach to have a detailed characterisation of the materials in a paint sample, assuring their localisation in the sample build-up. This analytical approach has been used to study samples from Catalan paintings by Josep Maria Sert y Badía (20th century), a muralist achieving international recognition whose canvases adorned international buildings. Results The pigments used by the painter as well as the organic materials used as binders and varnishes could be identified by means of conventional techniques. The distribution of these materials by means of Synchrotron Radiation based techniques allowed to establish the mixtures used by the painter depending on the purpose. Conclusions Results show the suitability of the combined use of SR μFTIR and SR μXRD mapping and conventional techniques to unequivocally identify all the materials present in the sample and their localization in the sample build-up. This kind of approach becomes indispensable to solve the challenge of micro heterogeneous samples. The complementary interpretation of the data obtained with all the different techniques allowed the characterization of both organic and inorganic materials in the samples layer by layer as well as to establish the painting techniques used by Sert in the works-of-art under study. PMID:22616949

  3. Comparison of conventional PCR, quantitative PCR, bacteriological culture and the Warthin Starry technique to detect Leptospira spp. in kidney and liver samples from naturally infected sheep from Brazil.

    PubMed

    Fornazari, Felipe; da Silva, Rodrigo Costa; Richini-Pereira, Virginia Bodelão; Beserra, Hugo Enrique Orsini; Luvizotto, Maria Cecília Rui; Langoni, Helio

    2012-09-01

    Leptospirosis is an infectious disease of worldwide importance. The development of diagnostic techniques allows sick animals to be identified, reservoirs to be eliminated and the disease prevented and controlled. The present study aimed to compare different techniques for diagnosing leptospirosis in sheep. Samples of kidney, liver and blood were collected from 465 animals that originated from a slaughterhouse. The sera were analyzed by the Microscopic Agglutination Test (MAT), and kidney and liver samples of seropositive animals were analyzed using four techniques: bacteriological culture, the Warthin Starry (WS) technique, conventional PCR (cPCR), and quantitative PCR (qPCR). With the MAT, 21 animals were positive (4.5%) to serovars Hardjo (n=12), Hebdomadis (n=5), Sentot (n=2), Wolfii (n=1) and Shermani (n=1). Titers were 100 (n=10), 200 (n=2), 400 (n=6) and 1600 (n=3). No animal was positive by bacteriological culture; four animals were positive by the WS technique in kidney samples; six animals were positive by cPCR in kidney samples; and 11 animals were positive by qPCR, eight of which in kidney samples and three in liver. The bacterial quantification revealed a median of 4.3 bacteria/μL in liver samples and 36.6 bacteria/μL in kidney samples. qPCR presented the highest sensitivity among the techniques, followed by cPCR, the WS technique and bacteriological culture. These results indicate that sheep can carry leptospires of the Sejroe serogroup, and demonstrate the efficiency of quantitative PCR to detect Leptospira spp. in tissue samples. Published by Elsevier B.V.

  4. Fibre Optic Sensors for Selected Wastewater Characteristics

    PubMed Central

    Chong, Su Sin; Abdul Aziz, A. R.; Harun, Sulaiman W.

    2013-01-01

    Demand for online and real-time measurements techniques to meet environmental regulation and treatment compliance are increasing. However the conventional techniques, which involve scheduled sampling and chemical analysis can be expensive and time consuming. Therefore cheaper and faster alternatives to monitor wastewater characteristics are required as alternatives to conventional methods. This paper reviews existing conventional techniques and optical and fibre optic sensors to determine selected wastewater characteristics which are colour, Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD). The review confirms that with appropriate configuration, calibration and fibre features the parameters can be determined with accuracy comparable to conventional method. With more research in this area, the potential for using FOS for online and real-time measurement of more wastewater parameters for various types of industrial effluent are promising. PMID:23881131

  5. Characterization of organic and conventional sweet basil leaves using chromatographic and flow-injection mass spectrometric (FIMS) fingerprints combined with principal component analysis

    PubMed Central

    Lu, Yingjian; Gao, Boyan; Chen, Pei; Charles, Denys; Yu, Liangli (Lucy)

    2014-01-01

    Sweet basil, Ocimum basilicum., is one of the most important and wildly used spices and has been shown to have antioxidant, antibacterial, and anti-diarrheal activities. In this study, high performance liquid chromatographic (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were used to differentiate organic and conventional sweet basil leaf samples. Principal component analysis (PCA) of the fingerprints indicated that both HPLC and FIMS fingerprints could effectively detect the chemical differences in the organic and conventional sweet basil leaf samples. This study suggested that the organic basil sample contained greater concentrations of almost all the major compounds than its conventional counterpart on a per same botanical weight basis. The FIMS method was able to rapidly differentiate the organic and conventional sweet basil leaf samples (1 min analysis time), whereas the HPLC fingerprints provided more information about the chemical composition of the basil samples with a longer analytical time. PMID:24518341

  6. Characterisation of organic and conventional sweet basil leaves using chromatographic and flow-injection mass spectrometric (FIMS) fingerprints combined with principal component analysis.

    PubMed

    Lu, Yingjian; Gao, Boyan; Chen, Pei; Charles, Denys; Yu, Liangli Lucy

    2014-07-01

    Sweet basil, Ocimum basilicum, is one of the most important and wildly used spices and has been shown to have antioxidant, antibacterial, and anti-diarrheal activities. In this study, high performance liquid chromatographic (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were used to differentiate organic and conventional sweet basil leaf samples. Principal component analysis (PCA) of the fingerprints indicated that both HPLC and FIMS fingerprints could effectively detect the chemical differences in the organic and conventional sweet basil leaf samples. This study suggested that the organic basil sample contained greater concentrations of almost all the major compounds than its conventional counterpart on a per same botanical weight basis. The FIMS method was able to rapidly differentiate the organic and conventional sweet basil leaf samples (1min analysis time), whereas the HPLC fingerprints provided more information about the chemical composition of the basil samples with a longer analytical time. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. A double sealing technique for increasing the precision of headspace-gas chromatographic analysis.

    PubMed

    Xie, Wei-Qi; Yu, Kong-Xian; Gong, Yi-Xian

    2018-01-19

    This paper investigates a new double sealing technique for increasing the precision of the headspace gas chromatographic method. The air leakage problem caused by the high pressure in the headspace vial during the headspace sampling process has a great impact to the measurement precision in the conventional headspace analysis (i.e., single sealing technique). The results (using ethanol solution as the model sample) show that the present technique is effective to minimize such a problem. The double sealing technique has an excellent measurement precision (RSD < 0.15%) and accuracy (recovery = 99.1%-100.6%) for the ethanol quantification. The detection precision of the present method was 10-20 times higher than that in earlier HS-GC work that use conventional single sealing technique. The present double sealing technique may open up a new avenue, and also serve as a general strategy for improving the performance (i.e., accuracy and precision) of headspace analysis of various volatile compounds. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Comparative Evaluation of Conventional and Accelerated Castings on Marginal Fit and Surface Roughness

    PubMed Central

    Jadhav, Vivek Dattatray; Motwani, Bhagwan K.; Shinde, Jitendra; Adhapure, Prasad

    2017-01-01

    Aims: The aim of this study was to evaluate the marginal fit and surface roughness of complete cast crowns made by a conventional and an accelerated casting technique. Settings and Design: This study was divided into three parts. In Part I, the marginal fit of full metal crowns made by both casting techniques in the vertical direction was checked, in Part II, the fit of sectional metal crowns in the horizontal direction made by both casting techniques was checked, and in Part III, the surface roughness of disc-shaped metal plate specimens made by both casting techniques was checked. Materials and Methods: A conventional technique was compared with an accelerated technique. In Part I of the study, the marginal fit of the full metal crowns as well as in Part II, the horizontal fit of sectional metal crowns made by both casting techniques was determined, and in Part III, the surface roughness of castings made with the same techniques was compared. Statistical Analysis Used: The results of the t-test and independent sample test do not indicate statistically significant differences in the marginal discrepancy detected between the two casting techniques. Results: For the marginal discrepancy and surface roughness, crowns fabricated with the accelerated technique were significantly different from those fabricated with the conventional technique. Conclusions: Accelerated casting technique showed quite satisfactory results, but the conventional technique was superior in terms of marginal fit and surface roughness. PMID:29042726

  9. Improved Dielectric Properties via Mechano-Chemical Activation in Ba0.80Pb0.20TiO3 Ceramics

    NASA Astrophysics Data System (ADS)

    Kumar, Parveen; Rani, Renu; Singh, Sangeeta; Juneja, J. K.; Prakash, Chandra; Raina, K. K.

    2011-12-01

    The present report is about the preparation and dielectric properties of commonly used Ba0.80Pb0.20TiO3 (BPT) ferroelectric ceramic via Mechano-Chemical Activation (MCA). Results were compared by the BPT sample prepared by conventional solid state method. The BPT sample prepared via MCA technique was found to have decreased tetragonality, dielectric constant value (ɛRT = 450 and ɛmax = 6170) approximately double the value for sample prepared by conventional method (ɛRT = 260 and ɛmax = 3275). Also, the sample prepared by MCA was found to be less frequency dependent. Thus, the BPT sample prepared via MCA is more suitable for capacitor applications requiring lesser frequency dependency than the conventionally prepared BPT sample.

  10. Preparation and analysis of standardized waste samples for Controlled Ecological Life Support Systems (CELSS)

    NASA Technical Reports Server (NTRS)

    Carden, J. L.; Browner, R.

    1982-01-01

    The preparation and analysis of standardized waste samples for controlled ecological life support systems (CELSS) are considered. Analysis of samples from wet oxidation experiments, the development of ion chromatographic techniques utilizing conventional high pressure liquid chromatography (HPLC) equipment, and an investigation of techniques for interfacing an ion chromatograph (IC) with an inductively coupled plasma optical emission spectrometer (ICPOES) are discussed.

  11. Lack of latex allergen contamination of solutions withdrawn from vials with natural rubber stoppers.

    PubMed

    Thomsen, D J; Burke, T G

    2000-01-01

    The effect on latex allergen contamination and microbial growth of a latex-allergy precaution technique for preparing injectable products was studied. The study consisted of three parts: (1) preparation of 20 samples from vials with latex-containing stoppers in accordance with conventional guidelines, (2) preparation of 20 samples in accordance with latex-allergy precaution guidelines, and (3) preparation of 5 latex-free samples and 1 latex-contaminated sample as negative and positive controls, respectively. The conventional method involved swabbing a vial top with an alcohol prep pad, puncturing the dry natural rubber stopper with an 18-gauge needle attached to a latex-free syringe, and withdrawing the contents of the vial into the syringe. The latex-allergy precaution preparation technique was similar, except that the stopper was removed before the vial contents were withdrawn. There was essentially no difference in latex allergen concentrations between the two drug preparation methods. None of the samples prepared with the standard method supported any microbial growth. One sample prepared with the latex-allergy precaution method grew bacteria. Removal of the dry rubber stopper from vials did not yield solutions with less latex allergen than solutions prepared according to conventional guidelines.

  12. Comparison Between Conventional and Automated Techniques for Blood Grouping and Crossmatching: Experience from a Tertiary Care Centre

    PubMed Central

    Bhagwat, Swarupa Nikhil; Sharma, Jayashree H; Jose, Julie; Modi, Charusmita J

    2015-01-01

    Context: The routine immunohematological tests can be performed by automated as well as manual techniques. These techniques have advantages and disadvantages inherent to them. Aims: The present study aims to compare the results of manual and automated techniques for blood grouping and crossmatching so as to validate the automated system effectively. Materials and Methods: A total of 1000 samples were subjected to blood grouping by the conventional tube technique (CTT) and the automated microplate LYRA system on Techno TwinStation. A total of 269 samples (multitransfused patients and multigravida females) were compared for 927 crossmatches by the CTT in indirect antiglobulin phase against the column agglutination technique (CAT) performed on Techno TwinStation. Results: For blood grouping, the study showed a concordance in results for 942/1000 samples (94.2%), discordance for 4/1000 (0.4%) samples and uninterpretable result for 54/1000 samples (5.4%). On resolution, the uninterpretable results reduced to 49/1000 samples (4.9%) with 951/1000 samples (95.1%) showing concordant results. For crossmatching, the automated CAT showed concordant results in 887/927 (95.6%) and discordant results in 3/927 (0.32%) crossmatches as compared to the CTT. Total 37/927 (3.9%) crossmatches were not interpretable by the automated technique. Conclusions: The automated system shows a high concordance of results with CTT and hence can be brought into routine use. However, the high proportion of uninterpretable results emphasizes on the fact that proper training and standardization are needed prior to its use. PMID:26417159

  13. Imbalanced Learning for Functional State Assessment

    NASA Technical Reports Server (NTRS)

    Li, Feng; McKenzie, Frederick; Li, Jiang; Zhang, Guangfan; Xu, Roger; Richey, Carl; Schnell, Tom

    2011-01-01

    This paper presents results of several imbalanced learning techniques applied to operator functional state assessment where the data is highly imbalanced, i.e., some function states (majority classes) have much more training samples than other states (minority classes). Conventional machine learning techniques usually tend to classify all data samples into majority classes and perform poorly for minority classes. In this study, we implemented five imbalanced learning techniques, including random undersampling, random over-sampling, synthetic minority over-sampling technique (SMOTE), borderline-SMOTE and adaptive synthetic sampling (ADASYN) to solve this problem. Experimental results on a benchmark driving lest dataset show thai accuracies for minority classes could be improved dramatically with a cost of slight performance degradations for majority classes,

  14. Comparing the Efficiency of Two Different Extraction Techniques in Removal of Maxillary Third Molars: A Randomized Controlled Trial.

    PubMed

    Edward, Joseph; Aziz, Mubarak A; Madhu Usha, Arjun; Narayanan, Jyothi K

    2017-12-01

    Extractions are routine procedures in dental surgery. Traditional extraction techniques use a combination of severing the periodontal attachment, luxation with an elevator, and removal with forceps. A new technique of extraction of maxillary third molar is introduced in this study-Joedds technique, which is compared with the conventional technique. One hundred people were included in the study, the people were divided into two groups by means of simple random sampling. In one group conventional technique of maxillary third molar extraction was used and on second Joedds technique was used. Statistical analysis was carried out with student's t test. Analysis of 100 patients based on parameters showed that the novel joedds technique had minimal trauma to surrounding tissues, less tuberosity and root fractures and the time taken for extraction was <2 min while compared to other group of patients. This novel technique has proved to be better than conventional third molar extraction technique, with minimal complications. If Proper selection of cases and right technique are used.

  15. Intact preservation of environmental samples by freezing under an alternating magnetic field.

    PubMed

    Morono, Yuki; Terada, Takeshi; Yamamoto, Yuhji; Xiao, Nan; Hirose, Takehiro; Sugeno, Masaya; Ohwada, Norio; Inagaki, Fumio

    2015-04-01

    The study of environmental samples requires a preservation system that stabilizes the sample structure, including cells and biomolecules. To address this fundamental issue, we tested the cell alive system (CAS)-freezing technique for subseafloor sediment core samples. In the CAS-freezing technique, an alternating magnetic field is applied during the freezing process to produce vibration of water molecules and achieve a stable, super-cooled liquid phase. Upon further cooling, the temperature decreases further, achieving a uniform freezing of sample with minimal ice crystal formation. In this study, samples were preserved using the CAS and conventional freezing techniques at 4, -20, -80 and -196 (liquid nitrogen) °C. After 6 months of storage, microbial cell counts by conventional freezing significantly decreased (down to 10.7% of initial), whereas that by CAS-freezing resulted in minimal. When Escherichia coli cells were tested under the same freezing conditions and storage for 2.5 months, CAS-frozen E. coli cells showed higher viability than the other conditions. In addition, an alternating magnetic field does not impact on the direction of remanent magnetization in sediment core samples, although slight partial demagnetization in intensity due to freezing was observed. Consequently, our data indicate that the CAS technique is highly useful for the preservation of environmental samples. © 2014 Society for Applied Microbiology and John Wiley & Sons Ltd.

  16. Extraction of kiwi seed oil: Soxhlet versus four different non-conventional techniques.

    PubMed

    Cravotto, Giancarlo; Bicchi, Carlo; Mantegna, Stefano; Binello, Arianna; Tomao, Valerie; Chemat, Farid

    2011-06-01

    Kiwi seed oil has a nutritionally interesting fatty acid profile, but a rather low oxidative stability, which requires careful extraction procedures and adequate packaging and storage. For these reasons and with the aim to achieve process intensification with shorter extraction time, lower energy consumption and higher yields, four different non-conventional techniques were experimented. Kiwi seeds were extracted in hexane using classic Soxhlet as well as under power ultrasound (US), microwaves (MWs; closed vessel) and MW-integrated Soxhlet. Supercritical CO₂ was also employed and compared to the other techniques in term of yield, extraction time, fatty acid profiles and organoleptic properties. All these non-conventional techniques are fast, effective and safe. A sensory evaluation test showed the presence of off-flavours in oil samples extracted by Soxhlet and US, an indicator of partial degradation.

  17. Office-based narrow band imaging-guided flexible laryngoscopy tissue sampling: A cost-effectiveness analysis evaluating its impact on Taiwanese health insurance program.

    PubMed

    Fang, Tuan-Jen; Li, Hsueh-Yu; Liao, Chun-Ta; Chiang, Hui-Chen; Chen, I-How

    2015-07-01

    Narrow band imaging (NBI)-guided flexible laryngoscopy tissue sampling for laryngopharyngeal lesions is a novel technique. Patients underwent the procedure in an office-based setting without being sedated, which is different from the conventional technique performed using direct laryngoscopy. Although the feasibility and effects of this procedure were established, its financial impact on the institution and Taiwanese National Health Insurance program was not determined. This is a retrospective case-control study. From May 2010 to April 2011, 20 consecutive patients who underwent NBI flexible laryngoscopy tissue sampling were recruited. During the same period, another 20 age-, sex-, and lesion-matched cases were enrolled in the control group. The courses for procedures and financial status were analyzed and compared between groups. Office-based NBI flexible laryngoscopy tissue sampling procedure took 27 minutes to be completed, while 191 minutes were required for the conventional technique. Average reimbursement for each case was New Taiwan Dollar (NT$)1264 for patients undergoing office-based NBI flexible laryngoscopy tissue sampling, while NT$10,913 for those undergoing conventional direct laryngoscopy in the operation room (p < 0.001). The institution suffered a loss of at least NT$690 when performing NBI flexible laryngoscopy tissue sampling. Office-based NBI flexible laryngoscopy tissue sampling is a cost-saving procedure for patients and the Taiwanese National Health Insurance program. It also saves the procedure time. However, the net financial loss for the institution and physician would limit its popularization unless reimbursement patterns are changed. Copyright © 2013. Published by Elsevier B.V.

  18. Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating.

    PubMed

    Bacchi, Atais; Regalin, Alexandre; Bhering, Claudia Lopes Brilhante; Alessandretti, Rodrigo; Spazzin, Aloisio Oro

    2015-10-01

    The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at 10(6) cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.

  19. Proteomic patterns for classification of ovarian cancer and CTCL serum samples utilizing peak pairs indicative of post-translational modifications.

    PubMed

    Liu, Chenwei; Shea, Nancy; Rucker, Sally; Harvey, Linda; Russo, Paul; Saul, Richard; Lopez, Mary F; Mikulskis, Alvydas; Kuzdzal, Scott; Golenko, Eva; Fishman, David; Vonderheid, Eric; Booher, Susan; Cowen, Edward W; Hwang, Sam T; Whiteley, Gordon R

    2007-11-01

    Proteomic patterns as a potential diagnostic technology has been well established for several cancer conditions and other diseases. The use of machine learning techniques such as decision trees, neural networks, genetic algorithms, and other methods has been the basis for pattern determination. Cancer is known to involve signaling pathways that are regulated through PTM of proteins. These modifications are also detectable with high confidence using high-resolution MS. We generated data using a prOTOF mass spectrometer on two sets of patient samples: ovarian cancer and cutaneous t-cell lymphoma (CTCL) with matched normal samples for each disease. Using the knowledge of mass shifts caused by common modifications, we built models using peak pairs and compared this to a conventional technique using individual peaks. The results for each disease showed that a small number of peak pairs gave classification equal to or better than the conventional technique that used multiple individual peaks. This simple peak picking technique could be used to guide identification of important peak pairs involved in the disease process.

  20. Timing Recovery Strategies in Magnetic Recording Systems

    NASA Astrophysics Data System (ADS)

    Kovintavewat, Piya

    At some point in a digital communications receiver, the received analog signal must be sampled. Good performance requires that these samples be taken at the right times. The process of synchronizing the sampler with the received analog waveform is known as timing recovery. Conventional timing recovery techniques perform well only when operating at high signal-to-noise ratio (SNR). Nonetheless, iterative error-control codes allow reliable communication at very low SNR, where conventional techniques fail. This paper provides a detailed review on the timing recovery strategies based on per-survivor processing (PSP) that are capable of working at low SNR. We also investigate their performance in magnetic recording systems because magnetic recording is a primary method of storage for a variety of applications, including desktop, mobile, and server systems. Results indicate that the timing recovery strategies based on PSP perform better than the conventional ones and are thus worth being employed in magnetic recording systems.

  1. A comparative study of conventionally sintered and microwave sintered nickel zinc ferrite

    NASA Astrophysics Data System (ADS)

    Rani, Rekha; Juneja, J. K.; Raina, K. K.; Kotnala, R. K.; Prakash, Chandra

    2014-04-01

    For the present work, nickel zinc ferrite having compositional formula Ni0.8Zn0.2Fe2O4 was synthesized by conventional solid state method and sintered in conventional and microwave furnaces. Pellets were sintered with very short soaking time of 10 min at 1150 °C in microwave furnace whereas 4 hrs of soaking time was selected for conventional sintering at 1200 °C. Phase formation was confirmed by X-ray diffraction analysis technique. Scanning electron micrographs were taken for microstructural study. Dielectric properties were studied as a function of temperature. To study magnetic behavior, M-H hysteresis loops were recorded for both samples. It is observed that microwave sintered sample could obtain comparable properties to the conventionally sintered one in lesser soaking time at lower sintering temperature.

  2. Rapid assessment of insect fauna based on local knowledge: comparing ecological and ethnobiological methods.

    PubMed

    Lima, Daniele Cristina de Oliveira; Ramos, Marcelo Alves; da Silva, Henrique Costa Hermenegildo; Alves, Angelo Giuseppe Chaves

    2016-03-01

    The rapid assessment of biodiversity making use of surveys of local knowledge has been successful for different biological taxa. However, there are no reports on the testing of such tools for sampling insect fauna. The present study aimed to evaluate the efficiency of different ethnobiological techniques for rapid sampling of insect fauna. Field research for the conventional survey of insect fauna was conducted on a private farm (9 ° 43'38.95 "S, 37 ° 45'11.97" W) , where there was intensive cultivation of okra (Abelmoschus esculentus L. (Moench)). The survey of local entomological knowledge was conducted among all the producers of okra living in the rural villages Pereira, Santa Luzia, and Nassau de Souza, within the Jacaré Curituba irrigated settlement scheme. The combined use of the techniques "free list" and projective interviews was analyzed, using two types of visual stimuli: stock photos and an entomological box. During the conventional survey of insect fauna, the species Bemisia tabaci biotype B, Aphis gossypii, Phenacoccus sp., Icerya purchasi and Lagria villosa were the primary pests found in the okra crop. Regarding the survey of insect pests, the results were convergent  in both techniques (conventional sampling and free list). Comparing the interview with visual stimuli (pictures) and specimen witnesses (entomological box) revealed that the latter was more effective. Techniques based on the recording and analysis of local knowledge about insects are effective for quick sampling of pest insects, but ineffective in sampling predator insects. The utilization of collected insects, infested branches, or photos of the symptoms of damage caused by pests in projective interviews is recommended.

  3. Direct Analysis of Samples of Various Origin and Composition Using Specific Types of Mass Spectrometry.

    PubMed

    Byliński, Hubert; Gębicki, Jacek; Dymerski, Tomasz; Namieśnik, Jacek

    2017-07-04

    One of the major sources of error that occur during chemical analysis utilizing the more conventional and established analytical techniques is the possibility of losing part of the analytes during the sample preparation stage. Unfortunately, this sample preparation stage is required to improve analytical sensitivity and precision. Direct techniques have helped to shorten or even bypass the sample preparation stage; and in this review, we comment of some of the new direct techniques that are mass-spectrometry based. The study presents information about the measurement techniques using mass spectrometry, which allow direct sample analysis, without sample preparation or limiting some pre-concentration steps. MALDI - MS, PTR - MS, SIFT - MS, DESI - MS techniques are discussed. These solutions have numerous applications in different fields of human activity due to their interesting properties. The advantages and disadvantages of these techniques are presented. The trends in development of direct analysis using the aforementioned techniques are also presented.

  4. Marginal accuracy of nickel chromium copings fabricated by conventional and accelerated casting procedures, produced with ringless and metal ring investment procedures: A comparative in vitro study.

    PubMed

    Alex, Deepa; Shetty, Y Bharath; Miranda, Glynis Anita; Prabhu, M Bharath; Karkera, Reshma

    2015-01-01

    Conventional investing and casting techniques are time-consuming and usually requires 2-4 h for completion. Accelerated nonstandard, casting techniques have been reported to achieve similar quality results in significantly less time, namely, in 30-40 min. During casting, it is essential to achieve compensation for the shrinkage of solidifying alloy by investment expansion. The metal casting ring restricts the thermal expansion of investment because the thermal expansion of the ring is lesser than that of the investment. The use of casting ring was challenged with the introduction of the ringless technique. A total of 40 test samples of nickel chromium (Ni-Cr) cast copings were obtained from the patterns fabricated using inlay casting wax. The 20 wax patterns were invested using metal ring and 20 wax patterns were invested using the ringless investment system. Of both the groups, 10 samples underwent conventional casting, and the other 10 underwent accelerated casting. The patterns were casted using the induction casting technique. All the test samples of cast copings were evaluated for vertical marginal gaps at four points on the die employing a stereo optical microscope. The vertical marginal discrepancy data obtained were tabulated. Mean and standard deviations were obtained. Vertical discrepancies were analyzed using analysis of variance and Tukey honestly significantly different. The data obtained were found to be very highly significant (P < 0.001). Mean vertical gap was the maximum for Group II (53.64 μm) followed by Group IV (47.62 μm), Group I (44.83 μm) and Group III (35.35 μm). The Ni-Cr cast copings fabricated with the conventional casting using ringless investment system showed significantly better marginal fit than that of cast copings fabricated from conventional and accelerated casting with metal ring investment and accelerated casting using ringless investment since those copings had shown the least vertical marginal discrepancies among the four methods evaluated in this study.

  5. Principles, Techniques, and Applications of Tissue Microfluidics

    NASA Technical Reports Server (NTRS)

    Wade, Lawrence A.; Kartalov, Emil P.; Shibata, Darryl; Taylor, Clive

    2011-01-01

    The principle of tissue microfluidics and its resultant techniques has been applied to cell analysis. Building microfluidics to suit a particular tissue sample would allow the rapid, reliable, inexpensive, highly parallelized, selective extraction of chosen regions of tissue for purposes of further biochemical analysis. Furthermore, the applicability of the techniques ranges beyond the described pathology application. For example, they would also allow the posing and successful answering of new sets of questions in many areas of fundamental research. The proposed integration of microfluidic techniques and tissue slice samples is called tissue microfluidics because it molds the microfluidic architectures in accordance with each particular structure of each specific tissue sample. Thus, microfluidics can be built around the tissues, following the tissue structure, or alternatively, the microfluidics can be adapted to the specific geometry of particular tissues. By contrast, the traditional approach is that microfluidic devices are structured in accordance with engineering considerations, while the biological components in applied devices are forced to comply with these engineering presets. The proposed principles represent a paradigm shift in microfluidic technology in three important ways: Microfluidic devices are to be directly integrated with, onto, or around tissue samples, in contrast to the conventional method of off-chip sample extraction followed by sample insertion in microfluidic devices. Architectural and operational principles of microfluidic devices are to be subordinated to suit specific tissue structure and needs, in contrast to the conventional method of building devices according to fluidic function alone and without regard to tissue structure. Sample acquisition from tissue is to be performed on-chip and is to be integrated with the diagnostic measurement within the same device, in contrast to the conventional method of off-chip sample prep and subsequent insertion into a diagnostic device. A more advanced form of tissue integration with microfluidics is tissue encapsulation, wherein the sample is completely encapsulated within a microfluidic device, to allow for full surface access. The immediate applications of these approaches lie with diagnostics of tissue slices and biopsy samples e.g. for cancer but the approaches would also be very useful in comparative genomics and other areas of fundamental research involving heterogeneous tissue samples.

  6. Measurement of the normalized broadband ultrasound attenuation in trabecular bone by using a bidirectional transverse transmission technique

    NASA Astrophysics Data System (ADS)

    Lee, Kang Il

    2015-01-01

    A new method for measuring the normalized broadband ultrasound attenuation (nBUA) in trabecular bone by using a bidirectional transverse transmission technique was proposed and validated with measurements obtained by using the conventional transverse transmission technique. There was no significant difference between the nBUA measurements obtained for 14 bovine femoral trabecular bone samples by using the bidirectional and the conventional transverse transmission techniques. The nBUA measured by using the two transverse transmission techniques showed strong positive correlations of r = 0.87 to 0.88 with the apparent bone density, consistent with the behavior in human trabecular bone invitro. We expect that the new method can be usefully applied for improved accuracy and precision in clinical measurements.

  7. A timer inventory based upon manual and automated analysis of ERTS-1 and supporting aircraft data using multistage probability sampling. [Plumas National Forest, California

    NASA Technical Reports Server (NTRS)

    Nichols, J. D.; Gialdini, M.; Jaakkola, S.

    1974-01-01

    A quasi-operational study demonstrating that a timber inventory based on manual and automated analysis of ERTS-1, supporting aircraft data and ground data was made using multistage sampling techniques. The inventory proved to be a timely, cost effective alternative to conventional timber inventory techniques. The timber volume on the Quincy Ranger District of the Plumas National Forest was estimated to be 2.44 billion board feet with a sampling error of 8.2 percent. Costs per acre for the inventory procedure at 1.1 cent/acre compared favorably with the costs of a conventional inventory at 25 cents/acre. A point-by-point comparison of CALSCAN-classified ERTS data with human-interpreted low altitude photo plots indicated no significant differences in the overall classification accuracies.

  8. Application of advanced techniques for the assessment of bio-stability of biowaste-derived residues: A minireview.

    PubMed

    Lü, Fan; Shao, Li-Ming; Zhang, Hua; Fu, Wen-Ding; Feng, Shi-Jin; Zhan, Liang-Tong; Chen, Yun-Min; He, Pin-Jing

    2018-01-01

    Bio-stability is a key feature for the utilization and final disposal of biowaste-derived residues, such as aerobic compost or vermicompost of food waste, bio-dried waste, anaerobic digestate or landfilled waste. The present paper reviews conventional methods and advanced techniques used for the assessment of bio-stability. The conventional methods are reclassified into two categories. Advanced techniques, including spectroscopic (fluorescent, ultraviolet-visible, infrared, Raman, nuclear magnetic resonance), thermogravimetric and thermochemolysis analysis, are emphasized for their application in bio-stability assessment in recent years. Their principles, pros and cons are critically discussed. These advanced techniques are found to be convenient in sample preparation and to supply diversified information. However, the viability of these techniques as potential indicators for bio-stability assessment ultimately lies in the establishment of the relationship of advanced ones with the conventional methods, especially with the methods based on biotic response. Furthermore, some misuses in data explanation should be noted. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Differentiating organically and conventionally grown oregano using ultraperformance liquid chromatography mass spectrometry (UPLC-MS), headspace gas chromatography with flame ionization detection (headspace-GC-FID), and flow injection mass spectrum (FIMS) fingerprints combined with multivariate data analysis.

    PubMed

    Gao, Boyan; Qin, Fang; Ding, Tingting; Chen, Yineng; Lu, Weiying; Yu, Liangli Lucy

    2014-08-13

    Ultraperformance liquid chromatography mass spectrometry (UPLC-MS), flow injection mass spectrometry (FIMS), and headspace gas chromatography (headspace-GC) combined with multivariate data analysis techniques were examined and compared in differentiating organically grown oregano from that grown conventionally. It is the first time that headspace-GC fingerprinting technology is reported in differentiating organically and conventionally grown spice samples. The results also indicated that UPLC-MS, FIMS, and headspace-GC-FID fingerprints with OPLS-DA were able to effectively distinguish oreganos under different growing conditions, whereas with PCA, only FIMS fingerprint could differentiate the organically and conventionally grown oregano samples. UPLC fingerprinting provided detailed information about the chemical composition of oregano with a longer analysis time, whereas FIMS finished a sample analysis within 1 min. On the other hand, headspace GC-FID fingerprinting required no sample pretreatment, suggesting its potential as a high-throughput method in distinguishing organically and conventionally grown oregano samples. In addition, chemical components in oregano were identified by their molecular weight using QTOF-MS and headspace-GC-MS.

  10. Comparative Study of Elemental Nutrients in Organic and Conventional Vegetables Using Laser-Induced Breakdown Spectroscopy (LIBS).

    PubMed

    Bhatt, Chet R; Alfarraj, Bader; Ghany, Charles T; Yueh, Fang Y; Singh, Jagdish P

    2017-04-01

    In this study, the laser-induced breakdown spectroscopy (LIBS) technique was used to identify and compare the presence of major nutrient elements in organic and conventional vegetables. Different parts of cauliflowers and broccolis were used as working samples. Laser-induced breakdown spectra from these samples were acquired at optimum values of laser energy, gate delay, and gate width. Both univariate and multivariate analyses were performed for the comparison of these organic and conventional vegetable flowers. Principal component analysis (PCA) was taken into account for multivariate analysis while for univariate analysis, the intensity of selected atomic lines of different elements and their intensity ratio with some reference lines of organic cauliflower and broccoli samples were compared with those of conventional ones. In addition, different parts of the cauliflower and broccoli were compared in terms of intensity and intensity ratio of elemental lines.

  11. Real-time explosive particle detection using a cyclone particle concentrator.

    PubMed

    Hashimoto, Yuichiro; Nagano, Hisashi; Takada, Yasuaki; Kashima, Hideo; Sugaya, Masakazu; Terada, Koichi; Sakairi, Minoru

    2014-06-30

    There is a need for more rapid methods for the detection of explosive particles. We have developed a novel real-time analysis technique for explosive particles that uses a cyclone particle concentrator. This technique can analyze sample surfaces for the presence of particles from explosives such as TNT and RDX within 3 s, which is much faster than is possible by conventional methods. Particles are detached from the sample surface with air jet pulses, and then introduced into a cyclone particle concentrator with a high pumping speed of about 80 L/min. A vaporizer placed at the bottom of the cyclone particle concentrator immediately converts the particles into a vapor. The vapor is then ionized in the atmospheric pressure chemical ionization (APCI) source of a linear ion trap mass spectrometer. An online connection between the vaporizer and a mass spectrometer enables high-speed detection within a few seconds, compared with the conventional off-line heating method that takes more than 10 s to raise the temperature of a sample filter unit. Since the configuration enriched the number density of explosive particles by about 80 times compared with that without the concentrator, a sub-ng amount of TNT particles on a surface was detectable. The detection limit of our technique is comparable with that of an explosives trace detector using ion mobility spectrometry. The technique will be beneficial for trace detection in security applications, because it detects explosive particles on the surface more speedily than conventional methods. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating

    PubMed Central

    Regalin, Alexandre; Bhering, Claudia Lopes Brilhante; Alessandretti, Rodrigo; Spazzin, Aloisio Oro

    2015-01-01

    PURPOSE The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. MATERIALS AND METHODS Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at 106 cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). RESULTS The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). CONCLUSION The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws. PMID:26576253

  13. Sampling Plans for the Thrips Frankliniella schultzei (Thysanoptera: Thripidae) in Three Lettuce Varieties.

    PubMed

    Silva, Alisson R; Rodrigues-Silva, Nilson; Pereira, Poliana S; Sarmento, Renato A; Costa, Thiago L; Galdino, Tarcísio V S; Picanço, Marcelo C

    2017-12-05

    The common blossom thrips, Frankliniella schultzei Trybom (Thysanoptera: Thripidae), is an important lettuce pest worldwide. Conventional sampling plans are the first step in implementing decision-making systems into integrated pest management programs. However, this tool is not available for F. schultzei infesting lettuce crops. Thus, the objective of this work was to develop a conventional sampling plan for F. schultzei in lettuce crops. Two sampling techniques (direct counting and leaf beating on a white plastic tray) were compared in crisphead, looseleaf, and Boston lettuce varieties before and during head formation. The frequency distributions of F. schultzei densities in lettuce crops were assessed, and the number of samples required to compose the sampling plan was determined. Leaf beating on a white plastic tray was the best sampling technique. F. schultzei densities obtained with this technique were fitted to the negative binomial distribution with a common aggregation parameter (common K = 0.3143). The developed sampling plan is composed of 91 samples per field and presents low errors in its estimates (up to 20%), fast execution time (up to 47 min), and low cost (up to US $1.67 per sampling area). This sampling plan can be used as a tool for integrated pest management in lettuce crops, assisting with reliable decision making in different lettuce varieties before and during head formation. © The Author(s) 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  14. Sample preparation for the analysis of isoflavones from soybeans and soy foods.

    PubMed

    Rostagno, M A; Villares, A; Guillamón, E; García-Lafuente, A; Martínez, J A

    2009-01-02

    This manuscript provides a review of the actual state and the most recent advances as well as current trends and future prospects in sample preparation and analysis for the quantification of isoflavones from soybeans and soy foods. Individual steps of the procedures used in sample preparation, including sample conservation, extraction techniques and methods, and post-extraction treatment procedures are discussed. The most commonly used methods for extraction of isoflavones with both conventional and "modern" techniques are examined in detail. These modern techniques include ultrasound-assisted extraction, pressurized liquid extraction, supercritical fluid extraction and microwave-assisted extraction. Other aspects such as stability during extraction and analysis by high performance liquid chromatography are also covered.

  15. Automatic transfer function generation for volume rendering of high-resolution x-ray 3D digital mammography images

    NASA Astrophysics Data System (ADS)

    Alyassin, Abdal M.

    2002-05-01

    3D Digital mammography (3DDM) is a new technology that provides high resolution X-ray breast tomographic data. Like any other tomographic medical imaging modalities, viewing a stack of tomographic images may require time especially if the images are of large matrix size. In addition, it may cause difficulty to conceptually construct 3D breast structures. Therefore, there is a need to readily visualize the data in 3D. However, one of the issues that hinder the usage of volume rendering (VR) is finding an automatic way to generate transfer functions that efficiently map the important diagnostic information in the data. We have developed a method that randomly samples the volume. Based on the mean and the standard deviation of these samples, the technique determines the lower limit and upper limit of a piecewise linear ramp transfer function. We have volume rendered several 3DDM data using this technique and compared visually the outcome with the result from a conventional automatic technique. The transfer function generated through the proposed technique provided superior VR images over the conventional technique. Furthermore, the improvement in the reproducibility of the transfer function correlated with the number of samples taken from the volume at the expense of the processing time.

  16. Comparison of three different adenoidectomy techniques in children - has the conventional technique been surpassed?

    PubMed

    Ferreira, Mayra Soares; Mangussi-Gomes, João; Ximendes, Roberta; Evangelista, Anne Rosso; Miranda, Eloá Lumi; Garcia, Leonardo Bomediano; Stamm, Aldo C

    2018-01-01

    Pharyngeal tonsil hyperplasia is the most frequent cause of nasal obstruction and chronic mouth breathing during childhood. Adenoidectomy is the procedure of choice for the resolution of these symptoms. It is not yet known, however, whether the conventional technique ("blind curettage") has been surpassed by more modern adenoidectomy techniques (video-assisted, with the aid of instruments). This study aimed to compare the conventional adenoidectomy technique with two other emerging techniques, performed in a reference otorhinolaryngology center. This is a prospective and observational study of 33 children submitted to adenoidectomy using 3 different techniques that were followed up for a period of 3 months after surgery. The patients were divided into 3 different groups, according to the adenoidectomy technique: Group A (conventional technique - "blind curettage"); Group B (video-assisted adenoidectomy with microdebrider); Group C (video-assisted adenoidectomy with radiofrequency - Coblation ® ). The surgical time of each procedure was measured, being considered from the moment of insertion of the mouth gag until complete hemostasis was achieved. The questionnaire for quality of life OSA-18 was applied to all caregivers on the day of the surgery and 30-90 days after the procedure. Postoperative complications were also analyzed. For the entire patient sample, there was an improvement in quality of life after the surgery (p < 0.05). When analyzing the evolution of OSA-18 index, all groups showed statistically significant improvement, for all assessed domains. There were no statistically significant differences between the 3 techniques assessed for quality of life improvement after the surgery (p > 0.05). Regarding the duration of the procedure, the conventional technique showed the shortest surgical time when compared to the others (p < 0.05). No postoperative complications were noted, for any patient. The adenoidectomy resulted in improvement of quality of life, and there were no major postoperative complications, for all operated children, regardless of the technique used. The conventional technique was faster when compared to the more modern adenoidectomy techniques. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Non-contact Creep Resistance Measurement for Ultra-High Temperature Materials

    NASA Technical Reports Server (NTRS)

    Lee, J.; Bradshaw, C.; Rogers, J. R.; Rathz, T. J.; Wall, J. J.; Choo, H.; Liaw, P. K.; Hyers, R. W.

    2005-01-01

    Conventional techniques for measuring creep are limited to about 1700 C, so a new technique is required for higher temperatures. This technique is based on electrostatic levitation (ESL) of a spherical sample, which is rotated quickly enough to cause creep deformation by centrifugal acceleration. Creep of samples has been demonstrated at up to 2300 C in the ESL facility at NASA MSFC, while ESL itself has been applied at over 3000 C, and has no theoretical maximum temperature. The preliminary results and future directions of this NASA-funded research collaboration will be presented.

  18. An inverter-based capacitive trans-impedance amplifier readout with offset cancellation and temporal noise reduction for IR focal plane array

    NASA Astrophysics Data System (ADS)

    Chen, Hsin-Han; Hsieh, Chih-Cheng

    2013-09-01

    This paper presents a readout integrated circuit (ROIC) with inverter-based capacitive trans-impedance amplifier (CTIA) and pseudo-multiple sampling technique for infrared focal plane array (IRFPA). The proposed inverter-based CTIA with a coupling capacitor [1], executing auto-zeroing technique to cancel out the varied offset voltage from process variation, is used to substitute differential amplifier in conventional CTIA. The tunable detector bias is applied from a global external bias before exposure. This scheme not only retains stable detector bias voltage and signal injection efficiency, but also reduces the pixel area as well. Pseudo-multiple sampling technique [2] is adopted to reduce the temporal noise of readout circuit. The noise reduction performance is comparable to the conventional multiple sampling operation without need of longer readout time proportional to the number of samples. A CMOS image sensor chip with 55×65 pixel array has been fabricated in 0.18um CMOS technology. It achieves a 12um×12um pixel size, a frame rate of 72 fps, a power-per-pixel of 0.66uW/pixel, and a readout temporal noise of 1.06mVrms (16 times of pseudo-multiple sampling), respectively.

  19. Monitoring beach changes using GPS surveying techniques

    USGS Publications Warehouse

    Morton, Robert; Leach, Mark P.; Paine, Jeffrey G.; Cardoza, Michael A.

    1993-01-01

    The adaptation of Global Positioning System (GPS) surveying techniques to beach monitoring activities is a promising response to this challenge. An experiment that employed both GPS and conventional beach surveying was conducted, and a new beach monitoring method employing kinematic GPS surveys was devised. This new method involves the collection of precise shore-parallel and shore-normal GPS positions from a moving vehicle so that an accurate two-dimensional beach surface can be generated. Results show that the GPS measurements agree with conventional shore-normal surveys at the 1 cm level, and repeated GPS measurements employing the moving vehicle demonstrate a precision of better than 1 cm. In addition, the nearly continuous sampling and increased resolution provided by the GPS surveying technique reveals alongshore changes in beach morphology that are undetected by conventional shore-normal profiles. The application of GPS surveying techniques combined with the refinement of appropriate methods for data collection and analysis provides a better understanding of beach changes, sediment transport, and storm impacts.

  20. Cross-sectional TEM specimen preparation for W/B{sub 4}C multilayer sample using FIB

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mondal, Puspen, E-mail: puspen@rrcat.gov.in; Pradhan, P. C.; Tiwari, Pragya

    2016-05-23

    A recent emergence of a cross-beam scanning electron microscopy (SEM)/focused-ion-beam (FIB) system have given choice to fabricate cross-sectional transmission electron microscopy (TEM) specimen of thin film multilayer sample. A 300 layer pair thin film multilayer sample of W/B{sub 4}C was used to demonstrate the specimen lift-out technique in very short time as compared to conventional cross-sectional sample preparation technique. To get large area electron transparent sample, sample prepared by FIB is followed by Ar{sup +} ion polishing at 2 kV with grazing incident. The prepared cross-sectional sample was characterized by transmission electron microscope.

  1. High-quality cell block preparation from scraping of conventional cytology slide: a technical report on a modified cytoscrape cell block technique.

    PubMed

    Choi, Y I; Jakhongir, M; Choi, S J; Kim, L; Park, I S; Han, J Y; Kim, J M; Chu, Y C

    2016-12-01

    Immunocytochemistry (ICC) on formalin-fixed paraffin embedded cell blocks is an ancillary tool commonly recruited for differential diagnoses of fine needle aspiration cytology (FNAC) samples. However, the quality of conventional cell blocks in terms of adequate cellularity and evenness of distribution of cytologic material is not always satisfactory for ICC. We introduce a modified agarose-based cytoscrape cell block (CCB) technique that can be effectively used for the preparation of cell blocks from scrapings of conventional FNAC slides. A decoverslipped FNAC slide was mounted with a small amount of water. The cytological material was scraped off the slide into a tissue mold by scraping with a cell scraper. The cytoscrape material was pelleted by centrifugation and pre-embedded in ultra-low gelling temperature agarose and then re-embedded in conventional agarose. The final agarose gel disk was processed and embedded in paraffin. The quality of the ICC on the CCB sections was identical to that of the immunohistochemical stains on histological sections. By scrapping and harvesting the entirety of the cytological material off the cytology slide into a compact agarose cell button, we could avoid the risk of losing diagnostic material during the CCB preparation. This modified CCB technique enables concentration and focusing of minute material while maintaining the entire amount of the cytoscrape material on the viewing spot of the CCB sections. We believe this technique can be effectively used to improve the level of confidence in diagnosis of FNAC especially when the FNAC slides are the only sample available.

  2. Marginal accuracy of nickel chromium copings fabricated by conventional and accelerated casting procedures, produced with ringless and metal ring investment procedures: A comparative in vitro study

    PubMed Central

    Alex, Deepa; Shetty, Y. Bharath; Miranda, Glynis Anita; Prabhu, M. Bharath; Karkera, Reshma

    2015-01-01

    Background: Conventional investing and casting techniques are time-consuming and usually requires 2–4 h for completion. Accelerated nonstandard, casting techniques have been reported to achieve similar quality results in significantly less time, namely, in 30–40 min. During casting, it is essential to achieve compensation for the shrinkage of solidifying alloy by investment expansion. The metal casting ring restricts the thermal expansion of investment because the thermal expansion of the ring is lesser than that of the investment. The use of casting ring was challenged with the introduction of the ringless technique. Materials and Methods: A total of 40 test samples of nickel chromium (Ni-Cr) cast copings were obtained from the patterns fabricated using inlay casting wax. The 20 wax patterns were invested using metal ring and 20 wax patterns were invested using the ringless investment system. Of both the groups, 10 samples underwent conventional casting, and the other 10 underwent accelerated casting. The patterns were casted using the induction casting technique. All the test samples of cast copings were evaluated for vertical marginal gaps at four points on the die employing a stereo optical microscope. Results: The vertical marginal discrepancy data obtained were tabulated. Mean and standard deviations were obtained. Vertical discrepancies were analyzed using analysis of variance and Tukey honestly significantly different. The data obtained were found to be very highly significant (P < 0.001). Mean vertical gap was the maximum for Group II (53.64 μm) followed by Group IV (47.62 μm), Group I (44.83 μm) and Group III (35.35 μm). Conclusion: The Ni-Cr cast copings fabricated with the conventional casting using ringless investment system showed significantly better marginal fit than that of cast copings fabricated from conventional and accelerated casting with metal ring investment and accelerated casting using ringless investment since those copings had shown the least vertical marginal discrepancies among the four methods evaluated in this study. PMID:26929488

  3. The Generation of Novel MR Imaging Techniques to Visualize Inflammatory/Degenerative Mechanisms and the Correlation of MR Data with 3D Microscopic Changes

    DTIC Science & Technology

    2012-09-01

    structures that are impossible with current methods . Using techniques to concurrently stain and three-dimensionally analyze many cell types and...new methods allowed us to visualize structures in these damaged samples that were not visible using conventional techniques allowing us modify our...AWARD NUMBER: W81XWH-11-1-0705 TITLE: The Generation of Novel MR Imaging Techniques to

  4. A technology roadmap of smart biosensors from conventional glucose monitoring systems.

    PubMed

    Shende, Pravin; Sahu, Pratiksha; Gaud, Ram

    2017-06-01

    The objective of this review article is to focus on technology roadmap of smart biosensors from a conventional glucose monitoring system. The estimation of glucose with commercially available devices involves analysis of blood samples that are obtained by pricking finger or extracting blood from the forearm. Since pain and discomfort are associated with invasive methods, the non-invasive measurement techniques have been investigated. The non-invasive methods show advantages like non-exposure to sharp objects such as needles and syringes, due to which there is an increase in testing frequency, improved control of glucose concentration and absence of pain and biohazard materials. This review study is aimed to describe recent invasive techniques and major noninvasive techniques, viz. biosensors, optical techniques and sensor-embedded contact lenses for glucose estimation.

  5. Fabrication of single domain GdBCO bulk superconductors by a new modified TSIG technique

    NASA Astrophysics Data System (ADS)

    Yang, W. M.; Zhi, X.; Chen, S. L.; Wang, M.; Li, J. W.; Ma, J.; Chao, X. X.

    2014-01-01

    Single domain GdBCO bulk superconductors have been fabricated with new and traditional solid phases by a top seeded infiltration and growth (TSIG) process technique. In the conventional TSIG process, three types of powders, such as Gd2BaCuO5, GdBa2Cu3O7-x and Ba3Cu5O8, must be prepared, but in our new modified TSIG technique, only BaCuO2 powders are required during the fabrication of the single domain GdBCO bulk superconductors. The solid phase used in the conventional process is Gd2BaCuO5 instead of the solid phase (Gd2O3 + BaCuO2) utilized in the new process. The liquid phase used in the conventional process is a mixture of (GdBa2Cu3O7-x + Ba3Cu5O8), and the liquid phase in the new process is a mixture of (Gd2O3 + 10BaCuO2 + 6CuO). Single domain GdBCO bulk superconductors have been fabricated with the new solid and liquid phases. The levitation force of the GdBCO bulk samples fabricated by the new solid phase is 28 N, which is slightly higher than that of the samples fabricated using the conventional solid phases (26 N). The microstructure and the levitation force of the samples indicate that this new method can greatly simplify the fabrication process, introduce nanometer-sized flux centers, improve the levitation force and working efficiency, and greatly reduce the cost of fabrication of single domain GdBCO bulk superconductors by the TSIG process.

  6. Label-free nanoscale characterization of red blood cell structure and dynamics using single-shot transport of intensity equation

    NASA Astrophysics Data System (ADS)

    Poola, Praveen Kumar; John, Renu

    2017-10-01

    We report the results of characterization of red blood cell (RBC) structure and its dynamics with nanometric sensitivity using transport of intensity equation microscopy (TIEM). Conventional transport of intensity technique requires three intensity images and hence is not suitable for studying real-time dynamics of live biological samples. However, assuming the sample to be homogeneous, phase retrieval using transport of intensity equation has been demonstrated with single defocused measurement with x-rays. We adopt this technique for quantitative phase light microscopy of homogenous cells like RBCs. The main merits of this technique are its simplicity, cost-effectiveness, and ease of implementation on a conventional microscope. The phase information can be easily merged with regular bright-field and fluorescence images to provide multidimensional (three-dimensional spatial and temporal) information without any extra complexity in the setup. The phase measurement from the TIEM has been characterized using polymeric microbeads and the noise stability of the system has been analyzed. We explore the structure and real-time dynamics of RBCs and the subdomain membrane fluctuations using this technique.

  7. Evaluation of mobile digital light-emitting diode fluorescence microscopy in Hanoi, Viet Nam.

    PubMed

    Chaisson, L H; Reber, C; Phan, H; Switz, N; Nilsson, L M; Myers, F; Nhung, N V; Luu, L; Pham, T; Vu, C; Nguyen, H; Nguyen, A; Dinh, T; Nahid, P; Fletcher, D A; Cattamanchi, A

    2015-09-01

    Hanoi Lung Hospital, Hanoi, Viet Nam. To compare the accuracy of CellScopeTB, a manually operated mobile digital fluorescence microscope, with conventional microscopy techniques. Patients referred for sputum smear microscopy to the Hanoi Lung Hospital from May to September 2013 were included. Ziehl-Neelsen (ZN) smear microscopy, conventional light-emitting diode (LED) fluorescence microscopy (FM), CellScopeTB-based LED FM and Xpert(®) MTB/RIF were performed on sputum samples. The sensitivity and specificity of microscopy techniques were determined in reference to Xpert results, and differences were compared using McNemar's paired test of proportions. Of 326 patients enrolled, 93 (28.5%) were Xpert-positive for TB. The sensitivity of ZN microscopy, conventional LED FM, and CellScopeTB-based LED FM was respectively 37.6% (95%CI 27.8-48.3), 41.9% (95%CI 31.8-52.6), and 35.5% (95%CI 25.8-46.1). The sensitivity of CellScopeTB was similar to that of conventional LED FM (difference -6.5%, 95%CI -18.2 to 5.3, P = 0.33) and ZN microscopy (difference -2.2%, 95%CI -9.2 to 4.9, P = 0.73). The specificity was >99% for all three techniques. CellScopeTB performed similarly to conventional microscopy techniques in the hands of experienced TB microscopists. However, the sensitivity of all sputum microscopy techniques was low. Options enabled by digital microscopy, such as automated imaging with real-time computerized analysis, should be explored to increase sensitivity.

  8. Determination techniques of Archie’s parameters: a, m and n in heterogeneous reservoirs

    NASA Astrophysics Data System (ADS)

    Mohamad, A. M.; Hamada, G. M.

    2017-12-01

    The determination of water saturation in a heterogeneous reservoir is becoming more challenging, as Archie’s equation is only suitable for clean homogeneous formation and Archie’s parameters are highly dependent on the properties of the rock. This study focuses on the measurement of Archie’s parameters in carbonate and sandstone core samples around Malaysian heterogeneous carbonate and sandstone reservoirs. Three techniques for the determination of Archie’s parameters a, m and n will be implemented: the conventional technique, core Archie parameter estimation (CAPE) and the three-dimensional regression technique (3D). By using the results obtained by the three different techniques, water saturation graphs were produced to observe the symbolic difference of Archie’s parameter and its relevant impact on water saturation values. The difference in water saturation values can be primarily attributed to showing the uncertainty level of Archie’s parameters, mainly in carbonate and sandstone rock samples. It is obvious that the accuracy of Archie’s parameters has a profound impact on the calculated water saturation values in carbonate sandstone reservoirs due to regions of high stress reducing electrical conduction resulting from the raised electrical heterogeneity of the heterogeneous carbonate core samples. Due to the unrealistic assumptions involved in the conventional method, it is better to use either the CAPE or 3D method to accurately determine Archie’s parameters in heterogeneous as well as homogeneous reservoirs.

  9. Improved importance sampling technique for efficient simulation of digital communication systems

    NASA Technical Reports Server (NTRS)

    Lu, Dingqing; Yao, Kung

    1988-01-01

    A new, improved importance sampling (IIS) approach to simulation is considered. Some basic concepts of IS are introduced, and detailed evolutions of simulation estimation variances for Monte Carlo (MC) and IS simulations are given. The general results obtained from these evolutions are applied to the specific previously known conventional importance sampling (CIS) technique and the new IIS technique. The derivation for a linear system with no signal random memory is considered in some detail. For the CIS technique, the optimum input scaling parameter is found, while for the IIS technique, the optimum translation parameter is found. The results are generalized to a linear system with memory and signals. Specific numerical and simulation results are given which show the advantages of CIS over MC and IIS over CIS for simulations of digital communications systems.

  10. How to Solve Polyhedron Problem?

    NASA Astrophysics Data System (ADS)

    Wijayanti, A.; Kusumah, Y. S.; Suhendra

    2017-09-01

    The purpose of this research is to know the possible strategies to solve the problem in polyhedron topic with Knilsey’s Learning Model as scaffolding for the student. This research was conducted by using mixed method with sequential explanatory design. Researchers used purposive sampling technique to get two classes for Knisley class and conventional class and an extreme case sampling technique to get interview data. The instruments used are tests, observation sheets and interview guidelines. The result of the research shows that: (1) students’ strategies to solve polyhedron problem were grouped into two steps: by partitioning the problem to find out the solution and make a mathematical model of the mathematical sentence given and then connect it with the concept that the students already know; (2) students ‘mathematical problem solving ability in Knisley class is higher than those in conventional class.

  11. Electron tomography of whole cultured cells using novel transmission electron imaging technique.

    PubMed

    Okumura, Taiga; Shoji, Minami; Hisada, Akiko; Ominami, Yusuke; Ito, Sukehiro; Ushiki, Tatsuo; Nakajima, Masato; Ohshima, Takashi

    2018-01-01

    Since a three-dimensional (3D) cellular ultrastructure is significant for biological functions, it has been investigated using various electron microscopic techniques. Although transmission electron microscopy (TEM)-based techniques are traditionally used, cells must be embedded in resin and sliced into ultrathin sections in sample preparation processes. Block-face observation using a scanning electron microscope (SEM) has also been recently applied to 3D observation of cellular components, but this is a destructive inspection and does not allow re-examination. Therefore, we developed electron tomography using a transmission electron imaging technique called Plate-TEM. With Plate-TEM, the cells cultured directly on a scintillator plate are inserted into a conventional SEM equipped with a Plate-TEM observation system, and their internal structures are observed by detecting scintillation light produced by electrons passing through the cells. This technology has the following four advantages. First, the cells cultured on the plate can be observed at electron-microscopic resolution since they remain on the plate. Second, both surface and internal information can be obtained simultaneously by using electron- and photo-detectors, respectively, because a Plate-TEM detector is installed in an SEM. Third, the cells on the scintillator plate can also be inspected using light microscopy because the plate has transparent features. Finally, correlative observation with other techniques, such as conventional TEM, is possible after Plate-TEM observation because Plate-TEM is a non-destructive analysis technique. We also designed a sample stage to tilt the samples for tomography with Plate-TEM, by which 3D organization of cellular structures can be visualized as a whole cell. In the present study, Mm2T cells were investigated using our tomography system, resulting in 3D visualization of cell organelles such as mitochondria, lipid droplets, and microvilli. Correlative observations with various imaging techniques were also conducted by successive observations with light microscopy, SEM, Plate-TEM, and conventional TEM. Consequently, the Plate-TEM tomography technique encourages understanding of cellular structures at high resolution, which can contribute to cellular biological research. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Modulated and continuous-wave operations of low-power thulium (Tm:YAP) laser in tissue welding

    NASA Astrophysics Data System (ADS)

    Bilici, Temel; Tabakoğlu, Haşim Özgür; Topaloğlu, Nermin; Kalaycıoğlu, Hamit; Kurt, Adnan; Sennaroglu, Alphan; Gülsoy, Murat

    2010-05-01

    Our aim is to explore the welding capabilities of a thulium (Tm:YAP) laser in modulated and continuous-wave (CW) modes of operation. The Tm:YAP laser system developed for this study includes a Tm:YAP laser resonator, diode laser driver, water chiller, modulation controller unit, and acquisition/control software. Full-thickness incisions on Wistar rat skin were welded by the Tm:YAP laser system at 100 mW and 5 s in both modulated and CW modes of operation (34.66 W/cm2). The skin samples were examined during a 21-day healing period by histology and tensile tests. The results were compared with the samples closed by conventional suture technique. For the laser groups, immediate closure at the surface layers of the incisions was observed. Full closures were observed for both modulated and CW modes of operation at day 4. The tensile forces for both modulated and CW modes of operation were found to be significantly higher than the values found by conventional suture technique. The 1980-nm Tm:YAP laser system operating in both modulated and CW modes maximizes the therapeutic effect while minimizing undesired side effects of laser tissue welding. Hence, it is a potentially important alternative tool to the conventional suturing technique.

  13. Analysis of estrogenic activity in environmental waters in Rio de Janeiro state (Brazil) using the yeast estrogen screen.

    PubMed

    Dias, Amanda Cristina Vieira; Gomes, Frederico Wegenast; Bila, Daniele Maia; Sant'Anna, Geraldo Lippel; Dezotti, Marcia

    2015-10-01

    The estrogenicity of waters collected from an important hydrological system in Brazil (Paraiba do Sul and Guandu Rivers) was assessed using the yeast estrogen screen (YES) assay. Sampling was performed in rivers and at the outlets of conventional water treatment plants (WTP). The removal of estrogenic activity by ozonation and chlorination after conventional water treatment (clarification and sand filtration) was investigated employing samples of the Guandu River spiked with estrogens and bisphenol A (BPA). The results revealed a preoccupying incidence of estrogenic activity at levels higher than 1ngL(-1) along some points of the rivers. Another matter of concern was the number of samples from WTPs presenting estrogenicity surpassing 1ngL(-1). The oxidation techniques (ozonation and chlorination) were effective for the removal of estrogenic activity and the combination of both techniques led to good results using less amounts of oxidants. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Micropowder collecting technique for stable isotope analysis of carbonates.

    PubMed

    Sakai, Saburo; Kodan, Tsuyoshi

    2011-05-15

    Micromilling is a conventional technique used in the analysis of the isotopic composition of geological materials, which improves the spatial resolution of sample collection for analysis. However, a problem still remains concerning the recovery ratio of the milled sample. We constructed a simple apparatus consisting of a vacuum pump, a sintered metal filter, electrically conductive rubber stopper and a stainless steel tube for transferring the milled powder into a reaction vial. In our preliminary experiments on carbonate powder, we achieved a rapid recovery of 5 to 100 µg of carbonate with a high recovery ratio (>90%). This technique shortens the sample preparation time, improves the recovery ratio, and homogenizes the sample quantity, which, in turn, improves the analytical reproducibility. Copyright © 2011 John Wiley & Sons, Ltd.

  15. Nanosecond time resolved x-ray diagnostics of relativistic electron beam initiated events

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuswa, Glenn W.; Chang, James

    The dynamic behavior of a test sample during aid shortly after it has teen irradiated by an intense relativistic electron beam (REB) is of great interest to the study of team energy deposition. Since the sample densities are far beyond the cutoff in the optical region, flash x-radiography techniques have been developed to diagnose the evolution of the samples. The conventional approach of analyzing the dynamic behavior of solid densities utilizes one or more short x-ray bursts to record images on photographic emulsion. This technique is not useful in the presence of the intense x-rays from the REB interacting withmore » the sample. We report two techniques for isolating the film package from the REB x-ray pulse.« less

  16. Evaluation of Microstructure and Mechanical Properties of Al-TiC Metal Matrix Composite Prepared by Conventional, Microwave and Spark Plasma Sintering Methods

    PubMed Central

    Ghasali, Ehsan; Fazili, Ali; Alizadeh, Masoud; Shirvanimoghaddam, Kamyar; Ebadzadeh, Touradj

    2017-01-01

    In this research, the mechanical properties and microstructure of Al-15 wt % TiC composite samples prepared by spark plasma, microwave, and conventional sintering were investigated. The sintering process was performed by the speak plasma sintering (SPS) technique, microwave and conventional furnaces at 400 °C, 600 °C, and 700 °C, respectively. The results showed that sintered samples by SPS have the highest relative density (99% of theoretical density), bending strength (291 ± 12 MPa), and hardness (253 ± 23 HV). The X-ray diffraction (XRD) investigations showed the formation of TiO2 from the surface layer decomposition of TiC particles. Scanning electron microscopy (SEM) micrographs demonstrated uniform distribution of reinforcement particles in all sintered samples. The SEM/EDS analysis revealed the formation of TiO2 around the porous TiC particles. PMID:29088114

  17. Thermal effusivity measurement of conventional and organic coffee oils via photopyroelectric technique.

    PubMed

    Bedoya, A; Gordillo-Delgado, F; Cruz-Santillana, Y E; Plazas, J; Marin, E

    2017-12-01

    In this work, oil samples extracted from organic and conventional coffee beans were studied. A fatty acids profile analysis was done using gas chromatography and physicochemical analysis of density and acidity index to verify the oil purity. Additionally, Mid-Infrared Fourier Transform Photoacoustic Spectroscopy (FTIR-PAS) aided by Principal Component Analysis (PCA) was used to identify differences between the intensities of the absorption bands related to functional groups. Thermal effusivity values between 592±3 and 610±4Ws 1/2 m -2 K -1 were measured using the photopyroelectric technique in a front detection configuration. The acidity index was between 1.11 and 1.27% and the density changed between 0.921 and 0.94g/mL. These variables, as well as the extraction yield between 12,6 and 14,4%, showed a similar behavior than that observed for the thermal effusivity, demonstrating that this parameter can be used as a criterion for discrimination between oil samples extracted from organic and conventional coffee beans. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Determination of the Molar Volume of Hydrogen from the Metal-Acid Reaction: An Experimental Alternative.

    ERIC Educational Resources Information Center

    de Berg, Kevin; Chapman, Ken

    1996-01-01

    Describes an alternative technique for determining the molar volume of hydrogen from the metal-acid reaction in which the metal sample is encased in a specially prepared cage and a pipette filler is used to fill an inverted burette with water. Eliminates some difficulties encountered with the conventional technique. (JRH)

  19. DETECTION OF HIGH MOLECULAR WEIGHT ORGANIC TRACERS IN VEGETATION SMOKE SAMPLES BY HIGH-TEMPERATURE GAS CHROMATOGRAPHY-MASS SPECTROMETRY. (R823990)

    EPA Science Inventory

    High-temperature high-resolution gas chromatography
    (HTGC) is an established technique for the separation of
    complex mixtures of high molecular weight (HMW) compounds
    which do not elute when analyzed on conventional GC
    columns. The combination of this technique wit...

  20. Critical review of analytical techniques for safeguarding the thorium-uranium fuel cycle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hakkila, E.A.

    1978-10-01

    Conventional analytical methods applicable to the determination of thorium, uranium, and plutonium in feed, product, and waste streams from reprocessing thorium-based nuclear reactor fuels are reviewed. Separations methods of interest for these analyses are discussed. Recommendations concerning the applicability of various techniques to reprocessing samples are included. 15 tables, 218 references.

  1. Tomographic diffractive microscopy with a wavefront sensor.

    PubMed

    Ruan, Y; Bon, P; Mudry, E; Maire, G; Chaumet, P C; Giovannini, H; Belkebir, K; Talneau, A; Wattellier, B; Monneret, S; Sentenac, A

    2012-05-15

    Tomographic diffractive microscopy is a recent imaging technique that reconstructs quantitatively the three-dimensional permittivity map of a sample with a resolution better than that of conventional wide-field microscopy. Its main drawbacks lie in the complexity of the setup and in the slowness of the image recording as both the amplitude and the phase of the field scattered by the sample need to be measured for hundreds of successive illumination angles. In this Letter, we show that, using a wavefront sensor, tomographic diffractive microscopy can be implemented easily on a conventional microscope. Moreover, the number of illuminations can be dramatically decreased if a constrained reconstruction algorithm is used to recover the sample map of permittivity.

  2. Untargeted metabolomics reveals specific withanolides and fatty acyl glycoside as tentative metabolites to differentiate organic and conventional Physalis peruviana fruits.

    PubMed

    Llano, Sandra M; Muñoz-Jiménez, Ana M; Jiménez-Cartagena, Claudio; Londoño-Londoño, Julián; Medina, Sonia

    2018-04-01

    The agronomic production systems may affect the levels of food metabolites. Metabolomics approaches have been applied as useful tool for the characterization of fruit metabolome. In this study, metabolomics techniques were used to assess the differences in phytochemical composition between goldenberry samples produced by organic and conventional systems. To verify that the organic samples were free of pesticides, individual pesticides were analyzed. Principal component analysis showed a clear separation of goldenberry samples from two different farming systems. Via targeted metabolomics assays, whereby carotenoids and ascorbic acid were analyzed, not statistical differences between both crops were found. Conversely, untargeted metabolomics allowed us to identify two withanolides and one fatty acyl glycoside as tentative metabolites to differentiate goldenberry fruits, recording organic fruits higher amounts of these compounds than conventional samples. Hence, untargeted metabolomics technology could be suitable to research differences on phytochemicals under different agricultural management practices and to authenticate organic products. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Conventional and Accelerated-Solvent Extractions of Green Tea (Camellia sinensis) for Metabolomics-based Chemometrics

    PubMed Central

    Kellogg, Joshua J.; Wallace, Emily D.; Graf, Tyler N.; Oberlies, Nicholas H.; Cech, Nadja B.

    2018-01-01

    Metabolomics has emerged as an important analytical technique for multiple applications. The value of information obtained from metabolomics analysis depends on the degree to which the entire metabolome is present and the reliability of sample treatment to ensure reproducibility across the study. The purpose of this study was to compare methods of preparing complex botanical extract samples prior to metabolomics profiling. Two extraction methodologies, accelerated solvent extraction and a conventional solvent maceration, were compared using commercial green tea [Camellia sinensis (L.) Kuntze (Theaceae)] products as a test case. The accelerated solvent protocol was first evaluated to ascertain critical factors influencing extraction using a D-optimal experimental design study. The accelerated solvent and conventional extraction methods yielded similar metabolite profiles for the green tea samples studied. The accelerated solvent extraction yielded higher total amounts of extracted catechins, was more reproducible, and required less active bench time to prepare the samples. This study demonstrates the effectiveness of accelerated solvent as an efficient methodology for metabolomics studies. PMID:28787673

  4. Conventional and Advanced Separations in Mass Spectrometry-Based Metabolomics: Methodologies and Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heyman, Heino M.; Zhang, Xing; Tang, Keqi

    2016-02-16

    Metabolomics is the quantitative analysis of all metabolites in a given sample. Due to the chemical complexity of the metabolome, optimal separations are required for comprehensive identification and quantification of sample constituents. This chapter provides an overview of both conventional and advanced separations methods in practice for reducing the complexity of metabolite extracts delivered to the mass spectrometer detector, and covers gas chromatography (GC), liquid chromatography (LC), capillary electrophoresis (CE), supercritical fluid chromatography (SFC) and ion mobility spectrometry (IMS) separation techniques coupled with mass spectrometry (MS) as both uni-dimensional and as multi-dimensional approaches.

  5. FOCIS: A forest classification and inventory system using LANDSAT and digital terrain data

    NASA Technical Reports Server (NTRS)

    Strahler, A. H.; Franklin, J.; Woodcook, C. E.; Logan, T. L.

    1981-01-01

    Accurate, cost-effective stratification of forest vegetation and timber inventory is the primary goal of a Forest Classification and Inventory System (FOCIS). Conventional timber stratification using photointerpretation can be time-consuming, costly, and inconsistent from analyst to analyst. FOCIS was designed to overcome these problems by using machine processing techniques to extract and process tonal, textural, and terrain information from registered LANDSAT multispectral and digital terrain data. Comparison of samples from timber strata identified by conventional procedures showed that both have about the same potential to reduce the variance of timber volume estimates over simple random sampling.

  6. Millimeter-wave monolithic integrated circuit characterization by a picosecond optoelectronic technique

    NASA Astrophysics Data System (ADS)

    Hung, Hing-Loi A.; Smith, Thane; Huang, Ho C.; Polak-Dingels, Penny; Webb, Kevin J.

    1989-08-01

    The characterization of microwave and millimeter-wave monolithic integrated circits (MIMICs) using picosecond pulse-sampling techniques is developed with emphasis on improving broadband coverage and measurement accuracy. GaAs photoconductive swithces are used for signal generation and sampling operations. The measured time-domain response allows the spectral transfer function of the MIMIC to be obtained. This measurement technique is verified by characterization of the frequency response (magnitude and phase) of a reference 50-ohm microstrip line and a two-stage Ka-band MIMIC amplifier. The measured broadband results agree with those obtained from conventional frequency-domain measurements using a network analyzer. The application of this optical technique to on-wafer MIMIC characterization is described.

  7. Method and apparatus for measuring nuclear magnetic properties

    DOEpatents

    Weitekamp, D.P.; Bielecki, A.; Zax, D.B.; Zilm, K.W.; Pines, A.

    1987-12-01

    A method for studying the chemical and structural characteristics of materials is disclosed. The method includes placement of a sample material in a high strength polarizing magnetic field to order the sample nuclei. The condition used to order the sample is then removed abruptly and the ordering of the sample allowed to evolve for a time interval. At the end of the time interval, the ordering of the sample is measured by conventional nuclear magnetic resonance techniques. 5 figs.

  8. Method and apparatus for measuring nuclear magnetic properties

    DOEpatents

    Weitekamp, Daniel P.; Bielecki, Anthony; Zax, David B.; Zilm, Kurt W.; Pines, Alexander

    1987-01-01

    A method for studying the chemical and structural characteristics of materials is disclosed. The method includes placement of a sample material in a high strength polarizing magnetic field to order the sample nucleii. The condition used to order the sample is then removed abruptly and the ordering of the sample allowed to evolve for a time interval. At the end of the time interval, the ordering of the sample is measured by conventional nuclear magnetic resonance techniques.

  9. Novel Sample-handling Approach for XRD Analysis with Minimal Sample Preparation

    NASA Technical Reports Server (NTRS)

    Sarrazin, P.; Chipera, S.; Bish, D.; Blake, D.; Feldman, S.; Vaniman, D.; Bryson, C.

    2004-01-01

    Sample preparation and sample handling are among the most critical operations associated with X-ray diffraction (XRD) analysis. These operations require attention in a laboratory environment, but they become a major constraint in the deployment of XRD instruments for robotic planetary exploration. We are developing a novel sample handling system that dramatically relaxes the constraints on sample preparation by allowing characterization of coarse-grained material that would normally be impossible to analyze with conventional powder-XRD techniques.

  10. Multiple exposure photographic (MEP) technique: an objective assessment of sperm motility in infertility management.

    PubMed

    Adetoro, O O

    1988-06-01

    Multiple exposure photography (MEP), an objective technique, was used in determining the percentage of motile sperms in the semen samples from 41 males being investigated for infertility. This technique was compared with the conventional subjective ordinary microscopy method of spermatozoal motility assessment. A satisfactory correlation was observed in percentage sperm motility assessment using the two methods but the MEP estimation was more consistent and reliable. The value of this technique of sperm motility study in the developing world is discussed.

  11. A comparative analysis of conventional cytopreparatory and liquid based cytological techniques (Sure Path) in evaluation of serous effusion fluids.

    PubMed

    Dadhich, Hrishikesh; Toi, Pampa Ch; Siddaraju, Neelaiah; Sevvanthi, Kalidas

    2016-11-01

    Clinically, detection of malignant cells in serous body fluids is critical, as their presence implies the upstaging of the disease. Cytology of body cavity fluids serves as an important tool when other diagnostic tests cannot be performed. In most laboratories, currently, the effusion fluid samples are analysed chiefly by the conventional cytopreparatory (CCP) technique. Although, there are several studies comparing the liquid-based cytology (LBC), with CCP technique in the field of cervicovaginal cytology; the literature on such comparison with respect to serous body fluid examination is sparse. One hundred samples of serous body fluids were processed by both CCP and LBC techniques. Slides prepared by these techniques were studied using six parameters. A comparative analysis of the advantages and disadvantages of the techniques in detection of malignant cells was carried out with appropriate statistical tests. The samples comprised 52 pleural, 44 peritoneal and four pericardial fluids. No statistically significant difference was noted with respect to cellularity (P values = 0.22), cell distribution (P values = 0.39) and diagnosis of malignancy (P values = 0.20). As for the remaining parameters, LBC provided statistically significant clearer smear background (P values < 0.0001) and shorter screening time (P values < 0.0001), while CPP technique provided a significantly better staining quality (P values 0.01) and sharper cytomorphologic features (P values 0.05). Although, a reduced screening time and clearer smear background are the two major advantages of LBC; the CCP technique provides the better staining quality with sharper cytomorphologic features which is more critical from the cytologic interpretation point of view. Diagn. Cytopathol. 2016;44:874-879. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. [Application of array-based comparative genomic hybridization technique in genetic analysis of patients with spontaneous abortion].

    PubMed

    Chu, Y; Wu, D; Hou, Q F; Huo, X D; Gao, Y; Wang, T; Wang, H D; Yang, Y L; Liao, S X

    2016-08-25

    To investigate the value of array-based comparative genomic hybridization (array-CGH) technique for the detection of chromosomal analysis of miscarried embryo, and to provide genetic counseling for couples with spontaneous abortion. Totally 382 patients who underwent miscarriage were enrolled in this study. All aborted tissues were analyzed with conventional cytogenetic karyotyping and array-CGH, respectively. Through genetic analysis, all of the 382 specimens were successfully analyzed by array-CGH (100.0%, 382/382), and the detection rate of chromosomal aberrations was 46.6% (178/382). However, conventional karyotype analysis was successfully performed in 281 cases (73.6%, 281/382), and 113 (40.2%, 113/281) were found with chromosomal aberrations. Of these 178 samples identified by array-CGH, 163 samples (91.6%, 163/178) were aneuploidy, 15 samples (8.4%, 15/178) were segmental deletion and (or) duplication cases. Four of 10 cases with small segmental deletion and duplication were validated to be transferred from their fathers or mathers who were carriers of submicroscopic reciprocal translocation. Of these 113 abnormal karyotypes founded by conventional karyotyping, 108 cases (95.6%, 108/113) were aneuploidy and 5 cases (4.4%, 5/113) had chromosome structural aberrations. Most array-CGH results were consistent with conventional karyotyping but with 3 cases of discrepancy, which included 2 cases of triploids, 1 case of low-level mosaicism that undetcted by array-CGH. Compared with conventional karyotyping, there is an increased detection rate of chromosomal abnormalities when array-CGH is used to analyse the products of conception, primarilly because of its sucess with nonviable tissues. It could be a first-line method to determine the reason of miscarrage with higher accuracy and sensitivity.

  13. Method for improving accuracy in full evaporation headspace analysis.

    PubMed

    Xie, Wei-Qi; Chai, Xin-Sheng

    2017-05-01

    We report a new headspace analytical method in which multiple headspace extraction is incorporated with the full evaporation technique. The pressure uncertainty caused by the solid content change in the samples has a great impact to the measurement accuracy in the conventional full evaporation headspace analysis. The results (using ethanol solution as the model sample) showed that the present technique is effective to minimize such a problem. The proposed full evaporation multiple headspace extraction analysis technique is also automated and practical, and which could greatly broaden the applications of the full-evaporation-based headspace analysis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Microextraction by packed sorbent: an emerging, selective and high-throughput extraction technique in bioanalysis.

    PubMed

    Pereira, Jorge; Câmara, José S; Colmsjö, Anders; Abdel-Rehim, Mohamed

    2014-06-01

    Sample preparation is an important analytical step regarding the isolation and concentration of desired components from complex matrices and greatly influences their reliable and accurate analysis and data quality. It is the most labor-intensive and error-prone process in analytical methodology and, therefore, may influence the analytical performance of the target analytes quantification. Many conventional sample preparation methods are relatively complicated, involving time-consuming procedures and requiring large volumes of organic solvents. Recent trends in sample preparation include miniaturization, automation, high-throughput performance, on-line coupling with analytical instruments and low-cost operation through extremely low volume or no solvent consumption. Micro-extraction techniques, such as micro-extraction by packed sorbent (MEPS), have these advantages over the traditional techniques. This paper gives an overview of MEPS technique, including the role of sample preparation in bioanalysis, the MEPS description namely MEPS formats (on- and off-line), sorbents, experimental and protocols, factors that affect the MEPS performance, and the major advantages and limitations of MEPS compared with other sample preparation techniques. We also summarize MEPS recent applications in bioanalysis. Copyright © 2014 John Wiley & Sons, Ltd.

  15. Efficiency reduction and pseudo-convergence in replica exchange sampling of peptide folding unfolding equilibria

    NASA Astrophysics Data System (ADS)

    Denschlag, Robert; Lingenheil, Martin; Tavan, Paul

    2008-06-01

    Replica exchange (RE) molecular dynamics (MD) simulations are frequently applied to sample the folding-unfolding equilibria of β-hairpin peptides in solution, because efficiency gains are expected from this technique. Using a three-state Markov model featuring key aspects of β-hairpin folding we show that RE simulations can be less efficient than conventional techniques. Furthermore we demonstrate that one is easily seduced to erroneously assign convergence to the RE sampling, because RE ensembles can rapidly reach long-lived stationary states. We conclude that typical REMD simulations covering a few tens of nanoseconds are by far too short for sufficient sampling of β-hairpin folding-unfolding equilibria.

  16. [Determination of calcium, magnesium and potassium in nurtured cell by AAS with quick-pulsed nebulization technique and NaOH base digestion].

    PubMed

    Shi, C; Gao, S; Gun, S

    1997-06-01

    The sample is digested with 6% NaOH solution and an amount of 50 microl is used for protein content analysis by the method of Comassie Brilliant Blue G250, the residual is diluted with equal 0.4% Lathanurm-EDTA solution. Its Calcium magensium and potassium content are determined by AAS. With quick-pulsed nebulization technique. When a self-made micro-sampling device is used, 20microl of sample volume is needed and it is only the 1/10 approximately 1/20 of the sample volume required for conventional determination. Sensitivity, precision and rate of recovery agree well with those using regular wet ashing method.

  17. Bone Healing Around Dental Implants: Simplified vs Conventional Drilling Protocols at Speed of 400 rpm.

    PubMed

    Gil, Luiz Fernando; Sarendranath, Alvin; Neiva, Rodrigo; Marão, Heloisa F; Tovar, Nick; Bonfante, Estevam A; Janal, Malvin N; Castellano, Arthur; Coelho, Paulo G

    This study evaluated whether simplified drilling protocols would provide comparable histologic and histomorphometric results to conventional drilling protocols at a low rotational speed. A total of 48 alumina-blasted and acid-etched Ti-6Al-4V implants with two diameters (3.75 and 4.2 mm, n = 24 per group) were bilaterally placed in the tibiae of 12 dogs, under a low-speed protocol (400 rpm). Within the same diameter group, half of the implants were inserted after a simplified drilling procedure (pilot drill + final diameter drill), and the other half were placed using the conventional drilling procedure. After 3 and 5 weeks, the animals were euthanized, and the retrieved bone-implant samples were subjected to nondecalcified histologic sectioning. Histomorphology, bone-to-implant contact (BIC), and bone area fraction occupancy (BAFO) analysis were performed. Histology showed that new bone was formed around implants, and inflammation or bone resorption was not evident for both groups. Histomorphometrically, when all independent variables were collapsed over drilling technique, no differences were detected for BIC and BAFO; when drilling technique was analyzed as a function of time, the conventional groups reached statistically higher BIC and BAFO at 3 weeks, but comparable values between techniques were observed at 5 weeks; 4.2-mm implants obtained statistically higher BAFO relative to 3.75-mm implants. Based on the present methodology, the conventional technique improved bone formation at 3 weeks, and narrower implants were associated with less bone formation.

  18. Non-conventional technologies for data collection in Brazilian dissertations and theses.

    PubMed

    Salvador, Pétala Tuani Candido de Oliveira; Rodrigues, Cláudia Cristiane Filgueira Martins; de Lima, Kálya Yasmine Nunes; Alves, Kisna Yasmin Andrade; Santos, Viviane Euzébia Pereira

    2015-01-01

    to characterize non-conventional technologies used for data collection of dissertations and theses available in the Catalog of Theses and Dissertations (CEPEn) of the Brazilian Nursing Association (ABEn). this is a documentary research, whose data were collected in the catalogs of theses and dissertations available at the ABEn website, from Volumes XIX to XXI. The indicators collected were: academic level; educational institution; year; qualification of the author; setting; non-conventional technology used; type of technology; association with conventional techniques; methodological design; benefits and methodological limitations. from a total of 6346 studies, only 121 (1.91%) used non-conventional technologies for data collection, representing the fi nal sample of the study. it is concluded that Brazilian Nursing researches still need methodological innovations for data collection.

  19. Comparison of extraction techniques of robenidine from poultry feed samples.

    PubMed

    Wilga, Joanna; Wasik, Agata Kot-; Namieśnik, Jacek

    2007-10-31

    In this paper, effectiveness of six different commonly applied extraction techniques for the determination of robenidine in poultry feed has been compared. The sample preparation techniques included shaking, Soxhlet, Soxtec, ultrasonically assisted extraction, microwave - assisted extraction and accelerated solvent extraction. Comparison of these techniques was done with respect to the recovery extraction, temperature and time, reproducibility and solvent consumption. Every single extract was subjected to clean - up using aluminium oxide column (Pasteur pipette filled with 1g of aluminium oxide), from which robenidine was eluted with 10ml of methanol. The eluate from the clean-up column was collected in a volumetric flask, and finally it was analysed by HPLC-DAD-MS. In general, all extraction techniques were capable of isolating of robenidine from poultry feed, but the recovery obtained using modern extraction techniques was higher than that obtained using conventional techniques. In particular, accelerated solvent extraction was more superior to other techniques, which highlights the advantages of this sample preparation technique. However, in routine analysis, shaking and ultrasonically assisted extraction is still the preferred method for the solution of robenidine and other coccidiostatics.

  20. Comparison of a gel microcolumn assay with the conventional tube test for red blood cell alloantibody titration.

    PubMed

    Finck, Rachel; Lui-Deguzman, Carrie; Teng, Shih-Mao; Davis, Rebecca; Yuan, Shan

    2013-04-01

    Titration is a semiquantitative method used to estimate red blood cell (RBC) alloantibody reactivity. The conventional tube test (CTT) technique is the traditional method for performing titration studies. The gel microcolumn assay (GMA) is also a sensitive method to detect RBC alloantibodies. The aim of this study was to compare a GMA with the CTT technique in the performance of Rh and K alloantibody titration. Patient serum samples that contained an RBC alloantibody with a singular specificity were identified by routine blood bank workflow. Parallel titration studies were performed on these samples by both the CTT method and a GMA (ID-Micro Typing System anti-IgG gel card, Micro Typing Systems, Inc., an Ortho-Clinical Diagnostics Company). Forty-eight samples were included, including 11 anti-D, five anti-c, 13 anti-E, one anti-C, three anti-e, and 15 anti-K. Overall, the two methods generated identical results in 21 of 48 samples. For 42 samples (87.5%) the two methods generated results that were within one serial dilution, and for the remaining six samples, results were within two dilutions. GMA systems may perform comparably to the CTT in titrating alloantibodies to Rh and Kell antigens. © 2012 American Association of Blood Banks.

  1. Chromatic changes to artificial irises produced using different techniques

    NASA Astrophysics Data System (ADS)

    Bannwart, Lisiane Cristina; Goiato, Marcelo Coelho; dos Santos, Daniela Micheline; Moreno, Amália; Pesqueira, Aldiéris Alves; Haddad, Marcela Filié; Andreotti, Agda Marobo; de Medeiros, Rodrigo Antonio

    2013-05-01

    Ocular prostheses are important determinants of their users' aesthetic recovery and self-esteem. Because of use, ocular prostheses longevity is strongly affected by instability of the iris color due to polymerization. The goal of this study is to examine how the color of the artificial iris button is affected by different techniques of artificial wear and by the application of varnish following polymerization of the colorless acrylic resin that covers the colored paint. We produce 60 samples (n=10) according to the wear technique applied: conventional technique without varnish (PE); conventional technique with varnish (PEV); technique involving a prefabricated cap without varnish (CA); technique involving a prefabricated cap with varnish (CAV); technique involving inverted painting without varnish (PI); and technique involving inverted painting with varnish (PIV). Color readings using a spectrophotometer are taken before and after polymerization. We submitted the data obtained to analyses of variance and Tukey's test (P<0.05). The color test shows significant changes after polymerization in all groups. The PE and PI techniques have clinically acceptable values of ΔE, independent of whether we apply varnish to protect the paint. The PI technique produces the least color change, whereas the PE and CA techniques significantly improve color stability.

  2. Characterization of Electronic Materials HgZnSe and HgZnTe Using Innovative and Conventional Techniques

    NASA Technical Reports Server (NTRS)

    Tanton, George; Kesmodel, Roy; Burden, Judy; Su, Ching-Hua; Cobb, Sharon D.; Lehoczky, S. L.

    2000-01-01

    HgZnSe and HgZnTe are electronic materials of interest for potential IR detector and focal plane array applications due to their improved strength and compositional stability over HgCdTe, but they are difficult to grow on Earth and to fully characterize. Conventional contact methods of characterization, such as Hall and van der Paw, although adequate for many situations are typically labor intensive and not entirely suitable where only very small samples are available. To adequately characterize and compare properties of electronic materials grown in low earth orbit with those grown on Earth, innovative techniques are needed that complement existing methods. This paper describes the implementation and test results of a unique non-contact method of characterizing uniformity, mobility, and carrier concentration together with results from conventional methods applied to HgZnSe and HgZnTe. The innovative method has advantages over conventional contact methods since it circumvents problems of possible contamination from alloying electrical contacts to a sample and also has the capability to map a sample. Non- destructive mapping, the determination of the carrier concentration and mobility at each place on a sample, provides a means to quantitatively compare, at high spatial resolution, effects of microgravity on electronic properties and uniformity of electronic materials grown in low-Earth orbit with Earth grown materials. The mapping technique described here uses a 1mm diameter polarized beam of radiation to probe the sample. Activation of a magnetic field, in which the sample is placed, causes the plane of polarization of the probe beam to rotate. This Faraday rotation is a function of the free carrier concentration and the band parameters of the material. Maps of carrier concentration, mobility, and transmission generated from measurements of the Faraday rotation angles over the temperature range from 300K to 77K will be presented. New information on band parameters, obtained by combining results from conventional Hall measurements of the free carrier concentration with Faraday rotation measurements, will also be presented. One example of how this type of information was derived is illustrated in the following figure which shows Faraday rotation vs wavelength modeled for Hg(l-x)ZnxSe at a temperature of 300K and x=0.07. The plasma contribution, total Faraday rotation, and interband contribution to the Faraday rotation, are designated in the Figure as del(p), FR tot, and del(i) respectively. Experimentally measured values of FR tot, each indicated by + , agree acceptably well with the model at the probe wavelength of 10.6 microns. The model shows that at the probe wavelength, practically all the rotation is due to the plasma component, which can be expressed as delta(sub p)= 2pi(e(sup 3))NBL/c(sup 2)nm*(sup 2) omega(sup 2). In this equation, delta(sub p) is the rotation angle due to the free carrier plasma, N is the free carrier concentration, B the magnetic field strength, L the thickness of the sample, n the index of refraction, omega the probe radiation frequency, c the speed of light, e the electron charge, and m* the effective mass. A measurement of N by conventional techniques, combined with a measurement of the Faraday rotation angle allows m* to be accurately determined since it is an inverse square function.

  3. Photoacoustic spectroscopy of condensed matter

    NASA Technical Reports Server (NTRS)

    Somoano, R. B.

    1978-01-01

    Photoacoustic spectroscopy is a new analytical tool that provides a simple nondestructive technique for obtaining information about the electronic absorption spectrum of samples such as powders, semisolids, gels, and liquids. It can also be applied to samples which cannot be examined by conventional optical methods. Numerous applications of this technique in the field of inorganic and organic semiconductors, biology, and catalysis have been described. Among the advantages of photoacoustic spectroscopy, the signal is almost insensitive to light scattering by the sample and information can be obtained about nonradiative deactivation processes. Signal saturation, which can modify the intensity of individual absorption bands in special cases, is a drawback of the method.

  4. Design of a practical model-observer-based image quality assessment method for x-ray computed tomography imaging systems

    PubMed Central

    Tseng, Hsin-Wu; Fan, Jiahua; Kupinski, Matthew A.

    2016-01-01

    Abstract. The use of a channelization mechanism on model observers not only makes mimicking human visual behavior possible, but also reduces the amount of image data needed to estimate the model observer parameters. The channelized Hotelling observer (CHO) and channelized scanning linear observer (CSLO) have recently been used to assess CT image quality for detection tasks and combined detection/estimation tasks, respectively. Although the use of channels substantially reduces the amount of data required to compute image quality, the number of scans required for CT imaging is still not practical for routine use. It is our desire to further reduce the number of scans required to make CHO or CSLO an image quality tool for routine and frequent system validations and evaluations. This work explores different data-reduction schemes and designs an approach that requires only a few CT scans. Three different kinds of approaches are included in this study: a conventional CHO/CSLO technique with a large sample size, a conventional CHO/CSLO technique with fewer samples, and an approach that we will show requires fewer samples to mimic conventional performance with a large sample size. The mean value and standard deviation of areas under ROC/EROC curve were estimated using the well-validated shuffle approach. The results indicate that an 80% data reduction can be achieved without loss of accuracy. This substantial data reduction is a step toward a practical tool for routine-task-based QA/QC CT system assessment. PMID:27493982

  5. Instrumental color control for metallic coatings

    NASA Astrophysics Data System (ADS)

    Chou, W.; Han, Bing; Cui, Guihua; Rigg, Bryan; Luo, Ming R.

    2002-06-01

    This paper describes work investigating a suitable color quality control method for metallic coatings. A set of psychological experiments was carried out based upon 50 pairs of samples. The results were used to test the performance of various color difference formulae. Different techniques were developed by optimising the weights and/or the lightness parametric factors of colour differences calculated from the four measuring angles. The results show that the new techniques give a significant improvement compared to conventional techniques.

  6. Microleakage and penetration of a hydrophilic sealant and a conventional resin-based sealant as a function of preparation techniques: a laboratory study.

    PubMed

    Khogli, Ahmed Eltigani; Cauwels, Rita; Vercruysse, Chris; Verbeeck, Ronald; Martens, Luc

    2013-01-01

    Optimal pit and fissure sealing is determined by surface preparation techniques and choice of materials. This study aimed (i) to compare the microleakage and penetration depth of a hydrophilic sealant and a conventional resin-based sealant using one of the following preparation techniques: acid etching (AE) only, a diamond bur + AE, and Er:YAG laser combined with AE, and (ii) to evaluate the microleakage and penetration depth of the hydrophilic pit and fissure sealant on different surface conditions. Eighty recently extracted 3rd molars were randomly assigned to eight groups of ten teeth according to the material, preparation technique, and surface condition. For saliva contamination, 0.1 mL of fresh whole human saliva was used. All samples were submitted to 1000 thermal cycles and immersed in 2% methylene blue dye for 4 h. Sections were examined by a light microscope and analysed using image analysis software (Sigmascan(®)). The combination of Er:YAG + AE + conventional sealant showed the least microleakage. The sealing ability of the hydrophilic sealant was influenced by the surface condition. Er:YAG ablation significantly decreased the microleakage at the tooth-sealant interface compared to the non-invasive technique. The hydrophilic sealant applied on different surface conditions showed comparable result to the conventional resin-based sealant. © 2012 The Authors. International Journal of Paediatric Dentistry © 2012 BSPD, IAPD and Blackwell Publishing Ltd.

  7. Polymerase spiral reaction (PSR): a novel, visual isothermal amplification method for detection of canine parvovirus 2 genomic DNA.

    PubMed

    Gupta, Vikas; Chakravarti, Soumendu; Chander, Vishal; Majumder, Saurabh; Bhat, Shabir Ahmad; Gupta, Vivek Kumar; Nandi, Sukdeb

    2017-07-01

    Canine parvovirus-2 (CPV-2), which is ubiquitously distributed worldwide, causes severe and often fatal gastroenteritis in dogs. Accurate, differential and rapid diagnosis of canine parvoviral enteritis remains a challenge for clinicians. A recently developed isothermal amplification technique, polymerase spiral reaction (PSR), was optimized for the first time for a viral pathogen with reference recombinant plasmid standards from different CPV-2 antigenic variants (CPV-2, CPV-2a, CPV-2b and CPV-2c) and subsequently validated using clinical samples. Addition of chromogenic substrate SYBR Green I after the completion of the reaction resulted in bright green fluorescence in positive samples, while negative samples and a no-template control remained orange. These results were further substantiated through visualization of a laddering pattern of the PSR-amplified product in an agarose gel in positive cases and the absence of this pattern in no-template control and negative samples. The PSR assay was found to be highly specific, as it did not react with other putative canine pathogens (canine adenovirus 1 and canine distemper virus). The sensitivity of the newly developed PSR technique was compared with that of conventional PCR, real-time PCR and LAMP, using a serial tenfold dilution of canine parvovirus DNA. The detection limit of PSR was found to be at the femtogram level, which is comparable with that of real-time PCR and LAMP, which are ten times more sensitive than conventional PCR. The assay was validated using 90 clinical samples, of which 54 were found positive, while only 45 samples were positive in conventional PCR. This novel assay, which is fully compliant with the 'ASSURED' concept for disease diagnosis, provides a simple, rapid, specific, sensitive and cost-effective method for diagnosis of canine parvoviral enteritis in veterinary clinics.

  8. Histopathological and immunohistochemical approaches for the diagnosis of Pasteurellosis in swine population of Punjab.

    PubMed

    Bhat, Payal; Singh, Nittin Dev; Leishangthem, Geeta Devi; Kaur, Amninder; Mahajan, Vishal; Banga, Harmanjit Singh; Brar, Rajinder Singh

    2016-09-01

    Infectious porcine bronchopneumonia, caused by Pasteurella multocida , is a widespread disease of major economic significance. Thus, the aim of the present study was to diagnose swine Pasteurellosis using gross, histopathological, and immunopathological approaches in the swine population of Punjab and to compare the efficacy of immunohistochemical (IHC) techniques with conventional diagnostic techniques. A total of 71 adult swine lung samples showing gross pneumonic changes were collected along with the associated lymph nodes to carry out the study. The collected samples were then processed for histopathological and IHC studies. Out of the total 71 lung samples, 26 samples were found to be suspected for Pasteurellosis as per the microscopic changes observed, and out of these 26 samples, 16 cases were confirmed to be positive for Pasteurellosis by IHC. Varied macroscopic changes noted in lungs were pneumonic patches with consolidation of many lobes, congestion, and focal hemorrhages. Main lesions associated with lymph nodes were its enlargement and hemorrhages. Histologically, the lung showed fibrinous and suppurative bronchopneumonia, multifocal suppuration, thickening of septa with fibrin combined with cellular infiltration and edema. The higher IHC expression of P. multocida was seen in the bronchial epithelium besides in alveolar and bronchial exudate. Moreover, on comparing the histopathological and IHC scores which were calculated on the basis of characteristic microscopic lesions and number of antigen positive cells, respectively, a significant positive correlation (r=0.4234) was found. It was concluded that swine population of Punjab is having P. multocida infection. The gross and histopathological lesions can be helpful in the preliminary diagnosis of Pasteurellosis but needs to be supplemented by other immunodiagnostic tests. Moreover, IHC technique proved to be a specific, reliable, precise, and rapid technique to supplement these conventional methods of diagnosis for Pasteurellosis.

  9. Bacterial adhesion on conventional and self-ligating metallic brackets after surface treatment with plasma-polymerized hexamethyldisiloxane.

    PubMed

    Tupinambá, Rogerio Amaral; Claro, Cristiane Aparecida de Assis; Pereira, Cristiane Aparecida; Nobrega, Celestino José Prudente; Claro, Ana Paula Rosifini Alves

    2017-01-01

    Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic brackets using the Plasma-Enhanced Chemical Vapor Deposition (PECVD) radio frequency technique. The samples were divided into two groups according to the kind of bracket and two subgroups after surface treatment. Scanning Electron Microscopy (SEM) analysis was performed to assess the presence of bacterial adhesion over samples surfaces (slot and wings region) and film layer integrity. Surface roughness was assessed by Confocal Interferometry (CI) and surface wettability, by goniometry. For bacterial adhesion analysis, samples were exposed for 72 hours to a Streptococcus mutans solution for biofilm formation. The values obtained for surface roughness were analyzed using the Mann-Whitney test while biofilm adhesion were assessed by Kruskal-Wallis and SNK test. Significant statistical differences (p< 0.05) for surface roughness and bacterial adhesion reduction were observed on conventional brackets after surface treatment and between conventional and self-ligating brackets; no significant statistical differences were observed between self-ligating groups (p> 0.05). Plasma-polymerized film deposition was only effective on reducing surface roughness and bacterial adhesion in conventional brackets. It was also noted that conventional brackets showed lower biofilm adhesion than self-ligating brackets despite the absence of film.

  10. Production of durable expanded perlite microspheres in a Vertical Electrical Furnace

    NASA Astrophysics Data System (ADS)

    Panagiotis, M.; Angelopoulos, P.; Taxiarchou, M.; Paspaliaris, I.

    2016-04-01

    Expanded perlite constitutes one of the most competitive insulating materials that is widely used in construction and manufacturing industry due to its unique properties combination; it is white, natural, lightweight, chemically inert, and exhibits superior insulating properties (thermal and acoustic) and fire resistance. Conventionally, perlite expansion is performed in vertical gas-fired furnaces; the conventional perlite expansion process has certain disadvantages which affect expanded products quality, thus limiting their performance and range of applications. In order to overcome the drawbacks of the conventional expansion technique, a new perlite expansion process has been designed based on a vertical electrical furnace (VEF). In the current study, fine perlite samples (-150 μm) from Milos Island, Greece, were expansed in the novel VEF and a conventional gas-fired furnace with the aim to evaluate and compare the main physical properties of the expanded products. The novel expanded perlite particles were characterised by superior properties, namely increased compression strength, competitive water and oil absorption capability, size homogeneity, spherical shape and decreased surface porosity in comparison to conventionally expanded samples.

  11. Conventional and accelerated-solvent extractions of green tea (camellia sinensis) for metabolomics-based chemometrics.

    PubMed

    Kellogg, Joshua J; Wallace, Emily D; Graf, Tyler N; Oberlies, Nicholas H; Cech, Nadja B

    2017-10-25

    Metabolomics has emerged as an important analytical technique for multiple applications. The value of information obtained from metabolomics analysis depends on the degree to which the entire metabolome is present and the reliability of sample treatment to ensure reproducibility across the study. The purpose of this study was to compare methods of preparing complex botanical extract samples prior to metabolomics profiling. Two extraction methodologies, accelerated solvent extraction and a conventional solvent maceration, were compared using commercial green tea [Camellia sinensis (L.) Kuntze (Theaceae)] products as a test case. The accelerated solvent protocol was first evaluated to ascertain critical factors influencing extraction using a D-optimal experimental design study. The accelerated solvent and conventional extraction methods yielded similar metabolite profiles for the green tea samples studied. The accelerated solvent extraction yielded higher total amounts of extracted catechins, was more reproducible, and required less active bench time to prepare the samples. This study demonstrates the effectiveness of accelerated solvent as an efficient methodology for metabolomics studies. Copyright © 2017. Published by Elsevier B.V.

  12. PPO-ethanol system as wavelength shifter for the Cherenkov counting technique using a liquid scintillation counter

    NASA Astrophysics Data System (ADS)

    Takiue, Makoto; Fujii, Haruo; Ishikawa, Hiroaki

    1984-12-01

    2, 5-diphenyloxazole (PPO) has been proposed as a wavelength shifter for Cherenkov counting. Since PPO is not incorporated with water, we have introduced the fluor into water in the form of micelle using a PPO-ethanol system. This technique makes it possible to obtain a high Cherenkov counting efficiency under stable sample conditions, attributed to the proper spectrometric features of the PPO. The 32P Cherenkov counting efficiency (68.4%) obtained from this technique is large as that measured with a conventional Cherenkov technique.

  13. Damage-free polymer surface modification employing inward-type plasma

    NASA Astrophysics Data System (ADS)

    Kanou, Ryo; Suga, Hiroshi; Utsumi, Hideyuki; Takahashi, Satoshi; Shirayama, Yuya; Watanabe, Norimichi; Petit, Stèphane; Shimizu, Tetsuo

    2017-08-01

    Inward-type plasmas, which spread upstream against the gas flow in the capillary tube where the gas is discharged, can react with samples placed near the entrance of such a capillary tube. In this study, surface modification of polymer surfaces is conducted using inward plasma. The modification is also done by conventional microplasma jet, and the modified surfaces with two plasma techniques are characterized by contact angle measurement, X-ray photoemission spectroscopy (XPS), and atomic force microscopy (AFM). Although inward-plasma-treated surfaces are less hydrophilic than conventional plasma-treated ones, they are still sufficiently hydrophilic for surface coatings. In addition, it turns out that the polymer surfaces irradiated with the inward plasma yield much smoother surfaces than those treated with the conventional plasma jet. Thus, the inward plasma treatment is a viable technique when the surface flatness is crucial, such as for the surface coating of plastic lenses.

  14. A quick and effective method of limb preparation with health, safety and efficiency benefits.

    PubMed

    Naderi, N; Maw, K; Thomas, M; Boyce, D E; Shokrollahi, K

    2012-03-01

    Pre-operative limb preparation (PLP) usually involves lifting the limb and holding it in a fixed 'static' posture for several minutes. This is hazardous to theatre staff. Furthermore, 'painting' the limb can be time consuming and difficult areas such as between toes and fingers may remain unsterile. We demonstrate the time efficiency and asepsis achieved using the 'sterile bag' preparation technique. An additional advantage is the ability to prepare and anaesthetise a limb prior to theatre, increasing efficiency substantially for units with a large throughput of cases, such as day-case hand surgery lists. We monitored the duration of PLP in 20 patients using the 'sterile bag' technique compared to 20 patients using a conventional 'painting' method. Additionally, microbiology samples acquired from prepared upper limbs of 27 sequential patients operated on by a single surgeon over a two-month period were sent for culture immediately prior to commencement of surgery. The mean duration of the 'sterile bag' PLP was significantly lower than that of the conventional method (24 seconds vs 85 seconds, p=0.045). The technique can take as little as ten seconds (n=1). Final microbiology reports showed no growth for any of the 27 patients from whom a culture sample was taken. The sterile bag technique is effective in achieving asepsis, has the potential to increase theatre efficiency and reduces manual handling hazards compared to the conventional method. It is now taught to all theatre staff in our hospital during manual handling training. It can be undertaken in approximately ten seconds with practice for the upper limb.

  15. A fast infrared scanning technique for nondestructive testing

    NASA Astrophysics Data System (ADS)

    Hartikainen, Jari

    1989-04-01

    A simple and fast thermal NDT measurement system is described and its usefulness is demonstrated using a honeycomb structure as a test sample. The sample is heated with a hot air jet and the surface temperature differences due to subsurface defects are detected with a single HgCdTe detector. An image of the sample is formed by scanning over the sample surface with a deflection mirror in the y direction while moving the sample in the x direction. The measurement time is typically 6 s per image and several images are averaged to improve signal to noise ratio. The main advantages of this system compared to conventional infrared camera techniques are considerably reduced cost and the ease with which the system can be modified to various applications.

  16. Ionic liquid-based ultrasonic/microwave-assisted extraction combined with UPLC-MS-MS for the determination of tannins in Galla chinensis.

    PubMed

    Lu, Chunxia; Wang, Hongxin; Lv, Wenping; Ma, Chaoyang; Lou, Zaixiang; Xie, Jun; Liu, Bo

    2012-01-01

    Ionic liquid was used as extraction solvents and applied to the extraction of tannins from Galla chinensis in the simultaneous ultrasonic- and microwave-assisted extraction (UMAE) technique. Several parameters of UMAE were optimised, and the results were compared with of the conventional extraction techniques. Under optimal conditions, the content of tannins was 630.2 ± 12.1 mg g⁻¹. Compared with the conventional heat-reflux extraction, maceration extraction, regular ultrasound- and microwave-assisted extraction, the proposed approach exhibited higher efficiency (11.7-22.0% enhanced) and shorter extraction time (from 6 h to 1 min). The tannins were then identified by ultraperformance liquid chromatography tandem mass spectrometry. This study suggests that ionic liquid-based UMAE is an efficient, rapid, simple and green sample preparation technique.

  17. Polymerization shrinkage of a dental resin composite determined by a fiber optic Fizeau interferometer

    NASA Astrophysics Data System (ADS)

    Arenas, Gustavo; Noriega, Sergio; Vallo, Claudia; Duchowicz, Ricardo

    2007-03-01

    A fiber optic sensing method based on a Fizeau-type interferometric scheme was employed for monitoring linear polymerization shrinkage in dental restoratives. This technique offers several advantages over the conventional methods of measuring polymerization contraction. This simple, compact, non-invasive and self-calibrating system competes with both conventional and other high-resolution bulk interferometric techniques. In this work, an analysis of the quality of interference signal and fringes visibility was performed in order to characterize their resolution and application range. The measurements of percent linear contraction as a function of the sample thickness were carried out in this study on two dental composites: Filtek P60 (3M ESPE) Posterior Restorer and Filtek Z250 (3M ESPE) Universal Restorer. The results were discussed with respect to others obtained employing alternative techniques.

  18. Microstructure Instability in Cryogenically-Deformed Copper (Preprint)

    DTIC Science & Technology

    2011-03-01

    prepared using conventional metallographic techniques followed by electropolishing in a solution of 70 pct. orthophosphoric acid in water at ambient...at room temperatu re on the microhardness profile across the sample diameter is shown in Fig. 1. After 15 minutes, the microhardness distribution was

  19. Selective mixed-bed solid phase extraction of atrazine herbicide from environmental water samples using molecularly imprinted polymer.

    PubMed

    Zarejousheghani, Mashaalah; Fiedler, Petra; Möder, Monika; Borsdorf, Helko

    2014-11-01

    A novel approach for the selective extraction of organic target compounds from water samples has been developed using a mixed-bed solid phase extraction (mixed-bed SPE) technique. The molecularly imprinted polymer (MIP) particles are embedded in a network of silica gel to form a stable uniform porous bed. The capabilities of this method are demonstrated using atrazine as a model compound. In comparison to conventional molecularly imprinted-solid phase extraction (MISPE), the proposed mixed-bed MISPE method in combination with gas chromatography-mass spectrometry (GC-MS) analysis enables more reproducible and efficient extraction performance. After optimization of operational parameters (polymerization conditions, bed matrix ingredients, polymer to silica gel ratio, pH of the sample solution, breakthrough volume plus washing and elution conditions), improved LODs (1.34 µg L(-1) in comparison to 2.25 µg L(-1) obtained using MISPE) and limits of quantification (4.5 µg L(-1) for mixed-bed MISPE and 7.5 µg L(-1) for MISPE) were observed for the analysis of atrazine. Furthermore, the relative standard deviations (RSDs) for atrazine at concentrations between 5 and 200 µg L(-1) ranged between 1.8% and 6.3% compared to MISPE (3.5-12.1%). Additionally, the column-to-column reproducibility for the mixed-bed MISPE was significantly improved to 16.1%, compared with 53% that was observed for MISPE. Due to the reduced bed-mass sorbent and at optimized conditions, the total amount of organic solvents required for conditioning, washing and elution steps reduced from more than 25 mL for conventional MISPE to less than 2 mL for mixed-bed MISPE. Besides reduced organic solvent consumption, total sample preparation time of the mixed-bed MISPE method relative to the conventional MISPE was reduced from more than 20 min to less than 10 min. The amount of organic solvent required for complete elution diminished from 3 mL (conventional MISPE) to less than 0.4 mL with the mixed-bed technique shows its inherent potential for online operation with an analytical instrument. In order to evaluate the selectivity and matrix effects of the developed mixed-bed MISPE method, it was applied as an extraction technique for atrazine from environmental wastewater and river water samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Space shuttle nonmetallic materials age life prediction

    NASA Technical Reports Server (NTRS)

    Mendenhall, G. D.; Hassell, J. A.; Nathan, R. A.

    1975-01-01

    The chemiluminescence from samples of polybutadiene, Viton, Teflon, Silicone, PL 731 Adhesive, and SP 296 Boron-Epoxy composite was measured at temperatures from 25 to 150 C. Excellent correlations were obtained between chemiluminescence and temperature. These correlations serve to validate accelerated aging tests (at elevated temperatures) designed to predict service life at lower temperatures. In most cases, smooth or linear correlations were obtained between chemiluminescence and physical properties of purified polymer gums, including the tensile strength, viscosity, and loss tangent. The latter is a complex function of certain polymer properties. Data were obtained with far greater ease by the chemiluminescence technique than by the conventional methods of study. The chemiluminescence from the Teflon (Halon) samples was discovered to arise from trace amounts of impurities, which were undetectable by conventional, destructive analysis of the sample.

  1. An in vitro comparison of photogrammetric and conventional complete-arch implant impression techniques.

    PubMed

    Bergin, Junping Ma; Rubenstein, Jeffrey E; Mancl, Lloyd; Brudvik, James S; Raigrodski, Ariel J

    2013-10-01

    Conventional impression techniques for recording the location and orientation of implant-supported, complete-arch prostheses are time consuming and prone to error. The direct optical recording of the location and orientation of implants, without the need for intermediate transfer steps, could reduce or eliminate those disadvantages. The objective of this study was to assess the feasibility of using a photogrammetric technique to record the location and orientation of multiple implants and to compare the results with those of a conventional complete-arch impression technique. A stone cast of an edentulous mandibular arch containing 5 implant analogs was fabricated to create a master model. The 3-dimensional (3D) spatial orientations of implant analogs on the master model were measured with a coordinate measuring machine (CMM) (control). Five definitive casts were made from the master model with a splinted impression technique. The positions of the implant analogs on the 5 casts were measured with a NobelProcera scanner (conventional method). Prototype optical targets were attached to the master model implant analogs, and 5 sets of images were recorded with a digital camera and a standardized image capture protocol. Dimensional data were imported into commercially available photogrammetry software (photogrammetric method). The precision and accuracy of the 2 methods were compared with a 2-sample t test (α=.05) and a 95% confidence interval. The location precision (standard error of measurement) for CMM was 3.9 µm (95% CI 2.7 to 7.1), for photogrammetry, 5.6 µm (95% CI 3.4 to 16.1), and for the conventional method, 17.2 µm (95% CI 10.3 to 49.4). The average measurement error was 26.2 µm (95% CI 15.9 to 36.6) for the conventional method and 28.8 µm (95% CI 24.8 to 32.9) for the photogrammetric method. The overall measurement accuracy was not significantly different when comparing the conventional to the photogrammetric method (mean difference = -2.6 µm, 95% CI -12.8 to 7.6). The precision of the photogrammetric method was similar to CMM, but lower for the conventional method as compared to CMM and the photogrammetric method. However, the overall measurement accuracy of the photogrammetric and conventional methods was similar. Copyright © 2013 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  2. Annealing of Co-Cr dental alloy: effects on nanostructure and Rockwell hardness.

    PubMed

    Ayyıldız, Simel; Soylu, Elif Hilal; Ide, Semra; Kılıç, Selim; Sipahi, Cumhur; Pişkin, Bulent; Gökçe, Hasan Suat

    2013-11-01

    The aim of the study was to evaluate the effect of annealing on the nanostructure and hardness of Co-Cr metal ceramic samples that were fabricated with a direct metal laser sintering (DMLS) technique. Five groups of Co-Cr dental alloy samples were manufactured in a rectangular form measuring 4 × 2 × 2 mm. Samples fabricated by a conventional casting technique (Group I) and prefabricated milling blanks (Group II) were examined as conventional technique groups. The DMLS samples were randomly divided into three groups as not annealed (Group III), annealed in argon atmosphere (Group IV), or annealed in oxygen atmosphere (Group V). The nanostructure was examined with the small-angle X-ray scattering method. The Rockwell hardness test was used to measure the hardness changes in each group, and the means and standard deviations were statistically analyzed by one-way ANOVA for comparison of continuous variables and Tukey's HSD test was used for post hoc analysis. P values of <.05 were accepted as statistically significant. The general nanostructures of the samples were composed of small spherical entities stacked atop one another in dendritic form. All groups also displayed different hardness values depending on the manufacturing technique. The annealing procedure and environment directly affected both the nanostructure and hardness of the Co-Cr alloy. Group III exhibited a non-homogeneous structure and increased hardness (48.16 ± 3.02 HRC) because the annealing process was incomplete and the inner stress was not relieved. Annealing in argon atmosphere of Group IV not only relieved the inner stresses but also decreased the hardness (27.40 ± 3.98 HRC). The results of fitting function presented that Group IV was the most homogeneous product as the minimum bilayer thickness was measured (7.11 Å). After the manufacturing with DMLS technique, annealing in argon atmosphere is an essential process for Co-Cr metal ceramic substructures. The dentists should be familiar with the materials that are used in clinic for prosthodontics treatments.

  3. Densitometry By Acoustic Levitation

    NASA Technical Reports Server (NTRS)

    Trinh, Eugene H.

    1989-01-01

    "Static" and "dynamic" methods developed for measuring mass density of acoustically levitated solid particle or liquid drop. "Static" method, unknown density of sample found by comparison with another sample of known density. "Dynamic" method practiced with or without gravitational field. Advantages over conventional density-measuring techniques: sample does not have to make contact with container or other solid surface, size and shape of samples do not affect measurement significantly, sound field does not have to be know in detail, and sample can be smaller than microliter. Detailed knowledge of acoustic field not necessary.

  4. Quantitative X-ray dark-field and phase tomography using single directional speckle scanning technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Hongchang, E-mail: hongchang.wang@diamond.ac.uk; Kashyap, Yogesh; Sawhney, Kawal

    2016-03-21

    X-ray dark-field contrast tomography can provide important supplementary information inside a sample to the conventional absorption tomography. Recently, the X-ray speckle based technique has been proposed to provide qualitative two-dimensional dark-field imaging with a simple experimental arrangement. In this letter, we deduce a relationship between the second moment of scattering angle distribution and cross-correlation degradation of speckle and establish a quantitative basis of X-ray dark-field tomography using single directional speckle scanning technique. In addition, the phase contrast images can be simultaneously retrieved permitting tomographic reconstruction, which yields enhanced contrast in weakly absorbing materials. Such complementary tomography technique can allow systematicmore » investigation of complex samples containing both soft and hard materials.« less

  5. Improving semi-automated segmentation by integrating learning with active sampling

    NASA Astrophysics Data System (ADS)

    Huo, Jing; Okada, Kazunori; Brown, Matthew

    2012-02-01

    Interactive segmentation algorithms such as GrowCut usually require quite a few user interactions to perform well, and have poor repeatability. In this study, we developed a novel technique to boost the performance of the interactive segmentation method GrowCut involving: 1) a novel "focused sampling" approach for supervised learning, as opposed to conventional random sampling; 2) boosting GrowCut using the machine learned results. We applied the proposed technique to the glioblastoma multiforme (GBM) brain tumor segmentation, and evaluated on a dataset of ten cases from a multiple center pharmaceutical drug trial. The results showed that the proposed system has the potential to reduce user interaction while maintaining similar segmentation accuracy.

  6. Vibrational Micro-Spectroscopy of Human Tissues Analysis: Review.

    PubMed

    Bunaciu, Andrei A; Hoang, Vu Dang; Aboul-Enein, Hassan Y

    2017-05-04

    Vibrational spectroscopy (Infrared (IR) and Raman) and, in particular, micro-spectroscopy and micro-spectroscopic imaging have been used to characterize developmental changes in tissues, to monitor these changes in cell cultures and to detect disease and drug-induced modifications. The conventional methods for biochemical and histophatological tissue characterization necessitate complex and "time-consuming" sample manipulations and the results are rarely quantifiable. The spectroscopy of molecular vibrations using mid-IR or Raman techniques has been applied to samples of human tissue. This article reviews the application of these vibrational spectroscopic techniques for analysis of biological tissue published between 2005 and 2015.

  7. Approximate formula for recalescence in binary eutectic alloys

    NASA Technical Reports Server (NTRS)

    Ohsaka, K.; Trinh, E. H.

    1993-01-01

    Supercooling of a liquid prior to the nucleation of a solid and the subsequent rapid growth are necessary conditions for producing novel microstructures including metastable phases which are not formed by conventional solidification processes. Since containerless techniques, such as levitation and free fall of a sample, are capable of achieving a significant supercooling level of liquids, they are under consideration as possible techniques for material processing on earth and in space.

  8. [Effect of techniques of composite resin insertion and polymerization on microleakage and microhardness].

    PubMed

    Amaral, Cristiane Mariote; Castro, Ana Karina Barbieri Bedran de; Pimenta, Luiz André Freire; Ambrosano, Glaucia Maria Boni

    2002-01-01

    The aim of this study was to evaluate the influence of techniques of composite resin polymerization and insertion on microleakage and microhardness. One hundred and eighty class II cavities were prepared in bovine teeth and assigned to six groups: G1 - bulk filling + conventional polymerization; G2 - bucco-lingual increments + conventional polymerization; G3 - bulk filling + soft-start polymerization; G4 - bucco-lingual increments + soft-start polymerization; G5 - bulk filling + progressive polymerization; G6 - bucco-lingual increments + progressive polymerization. All cavities were restored with the Z100/Single Bond system (3M). After thermocycling, the samples were immersed in 2% methylene blue dye solution for 4 hours. Half of the samples were embedded in polystyrene resin, and Knoop microhardness was measured. The Kruskal-Wallis test did not reveal statistical differences (p > 0.05) between the polymerization and insertion techniques as to microleakage. Regarding microhardness, the two-way ANOVA and the Tukey test did not reveal statistical differences between the restorative techniques (p > 0.05), but progressive polymerization (G5 and G6) was associated with smaller Knoop microhardness values (p < 0.05): G = 144.11; G2 = 143.89; G3 = 141.14; G4 = 142.79; G5 = 132.15; G6 = 131.67. It was concluded that the evaluated polymerization and insertion techniques did not affect marginal microleakage, but a decrease in microhardness occurred when progressive polymerization was carried out.

  9. Enhanced sampling techniques in biomolecular simulations.

    PubMed

    Spiwok, Vojtech; Sucur, Zoran; Hosek, Petr

    2015-11-01

    Biomolecular simulations are routinely used in biochemistry and molecular biology research; however, they often fail to match expectations of their impact on pharmaceutical and biotech industry. This is caused by the fact that a vast amount of computer time is required to simulate short episodes from the life of biomolecules. Several approaches have been developed to overcome this obstacle, including application of massively parallel and special purpose computers or non-conventional hardware. Methodological approaches are represented by coarse-grained models and enhanced sampling techniques. These techniques can show how the studied system behaves in long time-scales on the basis of relatively short simulations. This review presents an overview of new simulation approaches, the theory behind enhanced sampling methods and success stories of their applications with a direct impact on biotechnology or drug design. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Specificity of coliphages in evaluating marker efficacy: a new insight for water quality indicators.

    PubMed

    Mookerjee, Subham; Batabyal, Prasenjit; Halder, Madhumanti; Palit, Anup

    2014-11-01

    Conventional procedures for qualitative assessment of coliphage are time consuming multiple step approach for achieving results. A modified and rapid technique has been introduced for determination of coliphage contamination among potable water sources during water borne outbreaks. During December 2013, 40 water samples from different potable water sources, were received for water quality analyses, from a jaundice affected Municipality of West Bengal, India. Altogether, 30% water samples were contaminated with coliform (1-20 cfu/ml) and 5% with E. coli (2-5 cfu/ml). Among post-outbreak samples, preponderance of coliform has decreased (1-4 cfu/ml) with total absence of E. coli. While standard technique has detected 55% outbreak samples with coliphage contamination, modified technique revealed that 80%, double than that of bacteriological identification rate, were contaminated with coliphages (4-20 pfu/10 ml). However, post-outbreak samples were detected with 1-5 pfu/10 ml coliphages among 20% samples. Coliphage detection rate through modified technique was nearly double (50%) than that of standard technique (27.5%). In few samples (with coliform load of 10-100 cfu/ml), while modified technique could detect coliphages among six samples (10-20 pfu/10 ml), standard protocol failed to detect coliphage in any of them. An easy, rapid and accurate modified technique has thereby been implemented for coliphage assessment from water samples. Coliform free water does not always signify pathogen free potable water and it is demonstrated that coliphage is a more reliable 'biomarker' to ascertain contamination level in potable water. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. MUTAGENIC PROPERTIES OF RIVER WATERS FLOWING THROUGH BIG CITY AREAS IN NORTH AMERICA

    EPA Science Inventory

    The hanging technique using Blue rayon, which specifically adsorbs mutagens with multicyclic planer structures, has advantages over the conventional method of bringing-large volumes of water back to the laboratory for extraction. Therefore, the analysis of many samples from remot...

  12. Novel Techniques for Pulsed Field Gradient NMR Measurements

    NASA Astrophysics Data System (ADS)

    Brey, William Wallace

    Pulsed field gradient (PFG) techniques now find application in multiple quantum filtering and diffusion experiments as well as in magnetic resonance imaging and spatially selective spectroscopy. Conventionally, the gradient fields are produced by azimuthal and longitudinal currents on the surfaces of one or two cylinders. Using a series of planar units consisting of azimuthal and radial current elements spaced along the longitudinal axis, we have designed gradient coils having linear regions that extend axially nearly to the ends of the coil and to more than 80% of the inner radius. These designs locate the current return paths on a concentric cylinder, so the coils are called Concentric Return Path (CRP) coils. Coils having extended linear regions can be made smaller for a given sample size. Among the advantages that can accrue from using smaller coils are improved gradient strength and switching time, reduced eddy currents in the absence of shielding, and improved use of bore space. We used an approximation technique to predict the remaining eddy currents and a time-domain model of coil performance to simulate the electrical performance of the CRP coil and several reduced volume coils of more conventional design. One of the conventional coils was designed based on the time-domain performance model. A single-point acquisition technique was developed to measure the remaining eddy currents of the reduced volume coils. Adaptive sampling increases the dynamic range of the measurement. Measuring only the center of the stimulated echo removes chemical shift and B_0 inhomogeneity effects. The technique was also used to design an inverse filter to remove the eddy current effects in a larger coil set. We added pulsed field gradient and imaging capability to a 7 T commercial spectrometer to perform neuroscience and embryology research and used it in preliminary studies of binary liquid mixtures separating near a critical point. These techniques and coil designs will find application in research areas ranging from functional imaging to NMR microscopy.

  13. Monthly Strontium/Calcium oscillations in symbiotic coral aragonite: Biological effects limiting the precision of the paleotemperature proxy

    USGS Publications Warehouse

    Meibom, A.; Stage, M.; Wooden, J.; Constantz, B.R.; Dunbar, R.B.; Owen, A.; Grumet, N.; Bacon, C.R.; Chamberlain, C.P.

    2003-01-01

    In thermodynamic equilibrium with sea water the Sr/Ca ratio of aragonite varies predictably with temperature and the Sr/Ca ratio in coral have thus become a frequently used proxy for past Sea Surface Temperature (SST). However, biological effects can offset the Sr/Ca ratio from its equilibrium value. We report high spatial resolution ion microprobe analyses of well defined skeletal elements in the reef-building coral Porites lutea that reveal distinct monthly oscillations in the Sr/Ca ratio, with an amplitude in excess of ten percent. The extreme Sr/Ca variations, which we propose result from metabolic changes synchronous with the lunar cycle, introduce variability in Sr/Ca measurements based on conventional sampling techniques well beyond the analytical precision. These variations can limit the accuracy of Sr/Ca paleothermometry by conventional sampling techniques to about 2??C. Our results may help explain the notorious difficulties involved in obtaining an accurate and consistent calibration of the Sr/Ca vs. SST relationship.

  14. Viability PCR, a Culture-Independent Method for Rapid and Selective Quantification of Viable Legionella pneumophila Cells in Environmental Water Samples▿

    PubMed Central

    Delgado-Viscogliosi, Pilar; Solignac, Lydie; Delattre, Jean-Marie

    2009-01-01

    PCR-based methods have been developed to rapidly screen for Legionella pneumophila in water as an alternative to time-consuming culture techniques. However, these methods fail to discriminate between live and dead bacteria. Here, we report a viability assay (viability PCR [v-PCR]) for L. pneumophila that combines ethidium monoazide bromide with quantitative real-time PCR (qPCR). The ability of v-PCR to differentiate viable from nonviable L. pneumophila cells was confirmed with permeabilizing agents, toluene, or isopropanol. v-PCR suppressed more than 99.9% of the L. pneumophila PCR signal in nonviable cultures and was able to discriminate viable cells in mixed samples. A wide range of physiological states, from culturable to dead cells, was observed with 64 domestic hot-water samples after simultaneous quantification of L. pneumophila cells by v-PCR, conventional qPCR, and culture methods. v-PCR counts were equal to or higher than those obtained by culture and lower than or equal to conventional qPCR counts. v-PCR was used to successfully monitor in vitro the disinfection efficacy of heating to 70°C and glutaraldehyde and chlorine curative treatments. The v-PCR method appears to be a promising and rapid technique for enumerating L. pneumophila bacteria in water and, in comparison with conventional qPCR techniques used to monitor Legionella, has the advantage of selectively amplifying only viable cells. PMID:19363080

  15. Occurrence of aflatoxin M1 in conventional and organic milk offered for sale in Italy.

    PubMed

    Armorini, Sara; Altafini, Alberto; Zaghini, Anna; Roncada, Paola

    2016-11-01

    In the present study, 58 samples of milk were analyzed for the presence of aflatoxin M 1 (AFM 1 ). The samples were purchased during the period April-May 2013 in a random manner from local stores (supermarkets, small retail shops, small groceries, and specialized suppliers) located in the surrounding of Bologna (Italy). The commercial samples of milk were either organic (n = 22) or conventional (n = 36); fresh milk samples and UHT milk samples, whole milk samples, and partially skim milk samples were present in both the two considered categories. For the quantification of AFM 1 in milk, the extraction-purification technique based on the use of immunoaffinity columns was adopted and analyses were performed using HPLC-FD. AFM 1 was detected in 35 samples, 11 from organic production and 24 from conventional production. No statistically (P > 0.05) significant differences were observed in the concentration of AFM 1 in the two categories of product. The levels of contamination found in the positive samples ranged between 0.009 and 0.026 ng mL -1 . No sample exceeded the limit defined at community level for AFM 1 in milk (0.05 μg kg -1 ). This demonstrates the effectiveness of the checks before the placing on the market of these food products. Thus, the "aflatoxins" problem that characterized the summer of 2012 does not seem to have had effect on the contamination level of the considered milk samples.

  16. Bacterial adhesion on conventional and self-ligating metallic brackets after surface treatment with plasma-polymerized hexamethyldisiloxane

    PubMed Central

    Tupinambá, Rogerio Amaral; Claro, Cristiane Aparecida de Assis; Pereira, Cristiane Aparecida; Nobrega, Celestino José Prudente; Claro, Ana Paula Rosifini Alves

    2017-01-01

    ABSTRACT Introduction: Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Methods: Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic brackets using the Plasma-Enhanced Chemical Vapor Deposition (PECVD) radio frequency technique. The samples were divided into two groups according to the kind of bracket and two subgroups after surface treatment. Scanning Electron Microscopy (SEM) analysis was performed to assess the presence of bacterial adhesion over samples surfaces (slot and wings region) and film layer integrity. Surface roughness was assessed by Confocal Interferometry (CI) and surface wettability, by goniometry. For bacterial adhesion analysis, samples were exposed for 72 hours to a Streptococcus mutans solution for biofilm formation. The values obtained for surface roughness were analyzed using the Mann-Whitney test while biofilm adhesion were assessed by Kruskal-Wallis and SNK test. Results: Significant statistical differences (p< 0.05) for surface roughness and bacterial adhesion reduction were observed on conventional brackets after surface treatment and between conventional and self-ligating brackets; no significant statistical differences were observed between self-ligating groups (p> 0.05). Conclusion: Plasma-polymerized film deposition was only effective on reducing surface roughness and bacterial adhesion in conventional brackets. It was also noted that conventional brackets showed lower biofilm adhesion than self-ligating brackets despite the absence of film. PMID:28902253

  17. Effect of different mixing methods on the physical properties of Portland cement.

    PubMed

    Shahi, Shahriar; Ghasemi, Negin; Rahimi, Saeed; Yavari, Hamidreza; Samiei, Mohammad; Jafari, Farnaz

    2016-12-01

    The Portland cement is hydrophilic cement; as a result, the powder-to-liquid ratio affects the properties of the final mix. In addition, the mixing technique affects hydration. The aim of this study was to evaluate the effect of different mixing techniques (conventional, amalgamator and ultrasonic) on some selective physical properties of Portland cement. The physical properties to be evaluated were determined using the ISO 6786:2001 specification. One hundred sixty two samples of Portland cement were prepared for three mixing techniques for each physical property (each 6 samples). Data were analyzed using descriptive statistics, one-way ANOVA and post hoc Tukey tests. Statistical significance was set at P <0.05. The mixing technique had no significant effect on the compressive strength, film thickness and flow of Portland cement ( P >0.05). Dimensional changes (shrinkage), solubility and pH increased significantly by amalgamator and ultrasonic mixing techniques ( P <0.05). The ultrasonic technique significantly decreased working time, and the amalgamator and ultrasonic techniques significantly decreased the setting time ( P <0.05). The mixing technique exerted no significant effect on the flow, film thickness and compressive strength of Portland cement samples. Key words: Physical properties, Portland cement, mixing methods.

  18. Evaluation of marginal and internal gaps of metal ceramic crowns obtained from conventional impressions and casting techniques with those obtained from digital techniques.

    PubMed

    Rai, Rathika; Kumar, S Arun; Prabhu, R; Govindan, Ranjani Thillai; Tanveer, Faiz Mohamed

    2017-01-01

    Accuracy in fit of cast metal restoration has always remained as one of the primary factors in determining the success of the restoration. A well-fitting restoration needs to be accurate both along its margin and with regard to its internal surface. The aim of the study is to evaluate the marginal fit of metal ceramic crowns obtained by conventional inlay casting wax pattern using conventional impression with the metal ceramic crowns obtained by computer-aided design and computer-aided manufacturing (CAD/CAM) technique using direct and indirect optical scanning. This in vitro study on preformed custom-made stainless steel models with former assembly that resembles prepared tooth surfaces of standardized dimensions comprised three groups: the first group included ten samples of metal ceramic crowns fabricated with conventional technique, the second group included CAD/CAM-milled direct metal laser sintering (DMLS) crowns using indirect scanning, and the third group included DMLS crowns fabricated by direct scanning of the stainless steel model. The vertical marginal gap and the internal gap were evaluated with the stereomicroscope (Zoomstar 4); post hoc Turkey's test was used for statistical analysis. One-way analysis of variance method was used to compare the mean values. Metal ceramic crowns obtained from direct optical scanning showed the least marginal and internal gap when compared to the castings obtained from inlay casting wax and indirect optical scanning. Indirect and direct optical scanning had yielded results within clinically acceptable range.

  19. The influence of simultaneous integrated boost, hypofractionation and oncoplastic surgery on cosmetic outcome and PROMs after breast conserving therapy.

    PubMed

    Lansu, J T P; Essers, M; Voogd, A C; Luiten, E J T; Buijs, C; Groenendaal, N; Poortmans, P M H

    2015-10-01

    We retrospectively investigated the possible influence of a simultaneous integrated boost (SIB), hypofractionation and oncoplastic surgery on cosmetic outcome in 125 patients with stage I-II breast cancer treated with breast conserving therapy (BCT). The boost was given sequentially (55%) or by SIB (45%); fractionation was conventional (83%) or hypofractionated (17%); the surgical technique was a conventional lumpectomy (74%) or an oncoplastic technique (26%). We compared cosmetic results subjectively using a questionnaire independently completed by the patient and by the physician and objectively with the BCCT.core software. Independent-samples T-tests were used to compare outcome in different groups. Patients also completed the EORTC QLQ C30 and BR23. Univariate analyses indicated no significant differences of the cosmetic results (P ≤ 0.05) for the type of boost or fractionation. However, the conventional lumpectomy group scored significantly better than the oncoplastic group in the BCCT.core evaluation, without a significant difference in the subjective cosmetic evaluation. Quality of life outcome was in favour of SIB, hypofractionation and conventional surgery. Our study indicates that the current RT techniques seem to be safe for cosmetic outcome and quality of life. Further investigation is needed to verify the possible negative influence of oncoplastic surgery on the cosmetic outcome and the quality of life as this technique is especially indicated for patients with an unfavourable tumour/breast volume ratio. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Ensemble of sparse classifiers for high-dimensional biological data.

    PubMed

    Kim, Sunghan; Scalzo, Fabien; Telesca, Donatello; Hu, Xiao

    2015-01-01

    Biological data are often high in dimension while the number of samples is small. In such cases, the performance of classification can be improved by reducing the dimension of data, which is referred to as feature selection. Recently, a novel feature selection method has been proposed utilising the sparsity of high-dimensional biological data where a small subset of features accounts for most variance of the dataset. In this study we propose a new classification method for high-dimensional biological data, which performs both feature selection and classification within a single framework. Our proposed method utilises a sparse linear solution technique and the bootstrap aggregating algorithm. We tested its performance on four public mass spectrometry cancer datasets along with two other conventional classification techniques such as Support Vector Machines and Adaptive Boosting. The results demonstrate that our proposed method performs more accurate classification across various cancer datasets than those conventional classification techniques.

  1. Novel Polymerase Spiral Reaction (PSR) for rapid visual detection of Bovine Herpesvirus 1 genomic DNA from aborted bovine fetus and semen.

    PubMed

    Malla, Javed Ahmed; Chakravarti, Soumendu; Gupta, Vikas; Chander, Vishal; Sharma, Gaurav Kumar; Qureshi, Salauddin; Mishra, Adhiraj; Gupta, Vivek Kumar; Nandi, Sukdeb

    2018-02-20

    Bovine herpesvirus-1 (BHV-1) is a major viral pathogen affecting bovines leading to various clinical manifestations and causes significant economic impediment in modern livestock production system. Rapid, accurate and sensitive detection of BHV-1 infection at frozen semen stations or at dairy herds remains a priority for control of BHV-1 spread to susceptible population. Polymerase Spiral Reaction (PSR), a novel addition in the gamut of isothermal techniques, has been successfully implemented in initial optimization for detection of BHV-1 genomic DNA and further validated in clinical samples. The developed PSR assay has been validated for detection of BHV-1 from bovine semen (n=99), a major source of transmission of BHV-1 from breeding bulls to susceptible dams in artificial insemination programs. The technique has also been used for screening of BHV-1 DNA from suspected aborted fetal tissues (n=25). The developed PSR technique is 100 fold more sensitive than conventional PCR and comparable to real-time PCR. The PSR technique has been successful in detecting 13 samples positive for BHV-1 DNA in bovine semen, 4 samples more than conventional PCR. The aborted fetal tissues were negative for presence of BHV-1 DNA. The presence of BHV-1 in bovine semen samples raises a pertinent concern for extensively screening of semen from breeding bulls before been used for artificial insemination process. PSR has all the attributes for becoming a method of choice for rapid, accurate and sensitive detection of BHV-1 DNA at frozen semen stations or at dairy herds in resource constrained settings. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Gingival response in orthodontic patients: Comparative study between self-ligating and conventional brackets.

    PubMed

    Folco, Alejandra A; Benítez-Rogé, Sandra C; Iglesias, Marina; Calabrese, Diana; Pelizardi, Cristina; Rosa, Alcira; Brusca, Marisa I; Hecht, Pedro; Mateu, María E

    2014-01-01

    Orthodontic brackets contribute to the accumulation of bacterial plaque on tooth surfaces because they hinder oral hygiene. In contrast to conventional brackets, self-ligating brackets do not require additional parts to support the arches, thus improving dental hygiene. The aim of this study was to compare the gingival response in orthodontic patients wearing self-ligating or conventional brackets. A sample of 22 patients aged 16 to 30 years was divided into two groups: Group A, treated with selfligating brackets (Damon system) and Group B, treated with conventional brackets (Roth technique). The following were assessed during the treatment: Plaque Index (PI), Gingival Index (GI) and Probing Depth (PD), and sub-gingival samples were taken from teeth 14/24 for microbiological observation. No statistically significant difference was found between Groups A and B; p>0.05 (sign-ranked) or between PI, GI and PD at the different times (Friedman's Analysis of Variance), even though the indices were found to increase at 14 days, particularly for self-ligating brackets. The quantity and quality of microorganisms present were compatible with health on days 0, 28 and 56. As from day 14 there is a predominance of microbiota compatible with gingivitis in both groups. In the samples studied, orthodontic treatment increases bacterial plaque and inflammatory gingival response, but gingival-periodontal health can be maintained with adequate basic therapy. Self-ligating and conventional brackets produced similar gingival response.

  3. Pick a Sample.

    ERIC Educational Resources Information Center

    Peterson, Ivars

    1991-01-01

    A method that enables people to obtain the benefits of statistics and probability theory without the shortcomings of conventional methods because it is free of mathematical formulas and is easy to understand and use is described. A resampling technique called the "bootstrap" is discussed in terms of application and development. (KR)

  4. A novel rapid genotyping technique for Collie eye anomaly: SYBR Green-based real-time polymerase chain reaction method applicable to blood and saliva specimens on Flinders Technology Associates filter paper.

    PubMed

    Chang, Hye-Sook; Mizukami, Keijiro; Yabuki, Akira; Hossain, Mohammad A; Rahman, Mohammad M; Uddin, Mohammad M; Arai, Toshiro; Yamato, Osamu

    2010-09-01

    Collie eye anomaly (CEA) is a canine inherited ocular disease that shows a wide variety of manifestations and severity of clinical lesions. Recently, a CEA-associated mutation was reported, and a DNA test that uses conventional polymerase chain reaction (PCR) has now become available. The objective of the current study was to develop a novel rapid genotyping technique by using SYBR Green-based real-time PCR for future large-scale surveys as a key part in the strategy to eradicate CEA by selective breeding. First, a SYBR Green-based real-time PCR assay for genotyping of CEA was developed and evaluated by using purified DNA samples from normal, carrier, and affected Border Collies in which genotypes had previously been determined by conventional PCR. This real-time PCR assay demonstrated appropriate amplifications in all genotypes, and the results were consistent with those of conventional PCR. Second, the availability of Flinders Technology Associates filter paper (FTA card) as DNA templates for the real-time PCR assay was evaluated by using blood and saliva specimens to determine suitability for CEA screening. DNA-containing solution prepared from a disc of blood- or saliva-spotted FTA cards was available directly as templates for the real-time PCR assay when the volume of solution was 2.5% of the PCR mixture. In conclusion, SYBR Green-based real-time PCR combined with FTA cards is a rapid genotyping technique for CEA that can markedly shorten the overall time required for genotyping as well as simplify the sample preparation. Therefore, this newly developed technique suits large-scale screening in breeding populations of Collie-related breeds.

  5. Digital droplet multiple displacement amplification (ddMDA) for whole genome sequencing of limited DNA samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rhee, Minsoung; Light, Yooli K.; Meagher, Robert J.

    Here, multiple displacement amplification (MDA) is a widely used technique for amplification of DNA from samples containing limited amounts of DNA (e.g., uncultivable microbes or clinical samples) before whole genome sequencing. Despite its advantages of high yield and fidelity, it suffers from high amplification bias and non-specific amplification when amplifying sub-nanogram of template DNA. Here, we present a microfluidic digital droplet MDA (ddMDA) technique where partitioning of the template DNA into thousands of sub-nanoliter droplets, each containing a small number of DNA fragments, greatly reduces the competition among DNA fragments for primers and polymerase thereby greatly reducing amplification bias. Consequently,more » the ddMDA approach enabled a more uniform coverage of amplification over the entire length of the genome, with significantly lower bias and non-specific amplification than conventional MDA. For a sample containing 0.1 pg/μL of E. coli DNA (equivalent of ~3/1000 of an E. coli genome per droplet), ddMDA achieves a 65-fold increase in coverage in de novo assembly, and more than 20-fold increase in specificity (percentage of reads mapping to E. coli) compared to the conventional tube MDA. ddMDA offers a powerful method useful for many applications including medical diagnostics, forensics, and environmental microbiology.« less

  6. Digital droplet multiple displacement amplification (ddMDA) for whole genome sequencing of limited DNA samples

    DOE PAGES

    Rhee, Minsoung; Light, Yooli K.; Meagher, Robert J.; ...

    2016-05-04

    Here, multiple displacement amplification (MDA) is a widely used technique for amplification of DNA from samples containing limited amounts of DNA (e.g., uncultivable microbes or clinical samples) before whole genome sequencing. Despite its advantages of high yield and fidelity, it suffers from high amplification bias and non-specific amplification when amplifying sub-nanogram of template DNA. Here, we present a microfluidic digital droplet MDA (ddMDA) technique where partitioning of the template DNA into thousands of sub-nanoliter droplets, each containing a small number of DNA fragments, greatly reduces the competition among DNA fragments for primers and polymerase thereby greatly reducing amplification bias. Consequently,more » the ddMDA approach enabled a more uniform coverage of amplification over the entire length of the genome, with significantly lower bias and non-specific amplification than conventional MDA. For a sample containing 0.1 pg/μL of E. coli DNA (equivalent of ~3/1000 of an E. coli genome per droplet), ddMDA achieves a 65-fold increase in coverage in de novo assembly, and more than 20-fold increase in specificity (percentage of reads mapping to E. coli) compared to the conventional tube MDA. ddMDA offers a powerful method useful for many applications including medical diagnostics, forensics, and environmental microbiology.« less

  7. Conventional forceps or hot biopsy: comparative study of two methods in diagnosis of endobronchial lesions.

    PubMed

    Jabbari, Hamidreza; Fakhri, Mohammad; Lotfaliani, Mojtaba; Kiani, Arda

    2013-01-01

    It is suggested that hot electrocoagulation-enabled forceps (hot biopsy) may reduce hemorrhage risk after the biopsy in endobronchial tumors. The main concern in this method is possible reduction of the specimen's quality. To compare the procedure related hemorrhage with hot biopsy and conventional forceps biopsy and the diagnostic quality of the obtained specimens with either technique. In this prospective study, assessment of the biopsy samples and quantity of hemorrhage were done in a blind fashion. At first, for each patient a definite clinical diagnosis was made based on pathologic examination of all available samples, clinical data, and imaging findings. Then, second pathologist reviewed all samples to evaluate the quality of the samples. A total of 36 patients with endobronchial lesions were included in this study. Definite diagnosis was made in 83% of the patients. Diagnostic yield of the two methods were not statistically different, while the mean hemorrhage grades of all hot biopsy protocols were significantly lower as compared to that of conventional biopsy (p=0.003, p<0.001 and p<0.001 for 10,20and40 voltages respectively). No significant difference was detected between the qualities of specimens obtained by hot biopsy methods in comparison with conventional biopsy (p>0.05 for all three voltages). Hot biopsy can be a valuable alternative to forceps biopsy in evaluating endobronchial lesions.

  8. Development of a PCR technique specific for Demodex injai in biological specimens.

    PubMed

    Sastre, N; Ravera, I; Ferreira, D; Altet, L; Sánchez, A; Bardagí, M; Francino, O; Ferrer, L

    2013-09-01

    The identification of Demodex injai as a second Demodex species of dog opened new questions and challenges in the understanding on the Demodex-host relationships. In this paper, we describe the development of a conventional PCR technique based on published genome sequences of D. injai from GenBank that specifically detects DNA from D. injai. This technique amplifies a 238-bp fragment corresponding to a region of the mitochondrial 16S rDNA of D. injai. The PCR was positive in DNA samples obtained from mites identified morphologically as D. injai, which served as positive controls, as well as in samples from three cases of demodicosis associated with proliferation of mites identified as D. injai. Furthermore, the PCR was positive in 2 out of 19 healthy dogs. Samples of Demodex canis and Demodex folliculorum were consistently negative. Skin samples from seven dogs with generalized demodicosis caused by D. canis were all negative in the D. injai-specific PCR, demonstrating that in generalized canine demodicosis, mite proliferation is species-specific. This technique can be a useful tool in the diagnosis and in epidemiologic and pathogenic studies.

  9. Effect of different conventional melt quenching technique on purity of lithium niobate (LiNbO3) nano crystal phase formed in lithium borate glass

    NASA Astrophysics Data System (ADS)

    Kashif, Ismail; Soliman, Ashia A.; Sakr, Elham M.; Ratep, Asmaa

    2012-01-01

    The glass system (45Li2O + 45B2O3 + 10Nb2O5) was fabricated by the conventional melt quenching technique poured in water, at air, between two hot plates and droplets at the cooled surface. The glass and glass ceramics were studied by differential thermal analysis (DTA) and X-ray diffraction (XRD). The as quenched samples poured in water and between two hot plates were amorphous. The samples poured at air and on cooled surface were crystalline as established via X-ray powder diffraction (XRD) studies. Differential thermal analysis was measured. The glass transition temperature (Tg) and the crystallization temperatures were calculated. Lithium niobate (LiNbO3) was the main phase in glass ceramic poured at air, droplets at the cooled surface and the heat treated glass sample at 500, 540 and 580 °C in addition to traces from LiNb3O8. Crystallite size of the main phases determined from the X-ray diffraction peaks is in the range of <100 nm. The fraction of crystalline (LiNbO3) phase decreases with increase in the heat treatment temperature.

  10. A laser-deposition approach to compositional-spread discovery of materials on conventional sample sizes

    NASA Astrophysics Data System (ADS)

    Christen, Hans M.; Ohkubo, Isao; Rouleau, Christopher M.; Jellison, Gerald E., Jr.; Puretzky, Alex A.; Geohegan, David B.; Lowndes, Douglas H.

    2005-01-01

    Parallel (multi-sample) approaches, such as discrete combinatorial synthesis or continuous compositional-spread (CCS), can significantly increase the rate of materials discovery and process optimization. Here we review our generalized CCS method, based on pulsed-laser deposition, in which the synchronization between laser firing and substrate translation (behind a fixed slit aperture) yields the desired variations of composition and thickness. In situ alloying makes this approach applicable to the non-equilibrium synthesis of metastable phases. Deposition on a heater plate with a controlled spatial temperature variation can additionally be used for growth-temperature-dependence studies. Composition and temperature variations are controlled on length scales large enough to yield sample sizes sufficient for conventional characterization techniques (such as temperature-dependent measurements of resistivity or magnetic properties). This technique has been applied to various experimental studies, and we present here the results for the growth of electro-optic materials (SrxBa1-xNb2O6) and magnetic perovskites (Sr1-xCaxRuO3), and discuss the application to the understanding and optimization of catalysts used in the synthesis of dense forests of carbon nanotubes.

  11. Nitrogen isotopic analyses by isotope-ratio-monitoring gas chromatography/mass spectrometry

    NASA Technical Reports Server (NTRS)

    Merritt, D. A.; Hayes, J. M.

    1994-01-01

    Amino acids containing natural-abundance levels of 15N were derivatized and analyzed isotopically using a technique in which individual compounds are separated by gas chromatography, combusted on-line, and the product stream sent directly to an isotope-ratio mass spectrometer. For samples of N2 gas, standard deviations of ratio measurement were better than 0.1% (Units for delta are parts per thousand or per million (%).) for samples larger than 400 pmol and better than 0.5% for samples larger than 25 pmol (0.1% 15N is equivalent to 0.00004 atom % 15N). Results duplicated those of conventional, batchwise analyses to within 0.05%. For combustion of organic compounds yielding CO2/N2 ratios between 14 and 28, in particular for N-acetyl n-propyl derivatives of amino acids, delta values were within 0.25% of results obtained using conventional techniques and standard deviations were better than 0.35%. Pooled data for measurements of all amino acids produced an accuracy and precision of 0.04 and 0.23%, respectively, when 2 nmol of each amino acid was injected on column and 20% of the stream of combustion products was delivered to the mass spectrometer.

  12. Label-Free, Flow-Imaging Methods for Determination of Cell Concentration and Viability.

    PubMed

    Sediq, A S; Klem, R; Nejadnik, M R; Meij, P; Jiskoot, Wim

    2018-05-30

    To investigate the potential of two flow imaging microscopy (FIM) techniques (Micro-Flow Imaging (MFI) and FlowCAM) to determine total cell concentration and cell viability. B-lineage acute lymphoblastic leukemia (B-ALL) cells of 2 different donors were exposed to ambient conditions. Samples were taken at different days and measured with MFI, FlowCAM, hemocytometry and automated cell counting. Dead and live cells from a fresh B-ALL cell suspension were fractionated by flow cytometry in order to derive software filters based on morphological parameters of separate cell populations with MFI and FlowCAM. The filter sets were used to assess cell viability in the measured samples. All techniques gave fairly similar cell concentration values over the whole incubation period. MFI showed to be superior with respect to precision, whereas FlowCAM provided particle images with a higher resolution. Moreover, both FIM methods were able to provide similar results for cell viability as the conventional methods (hemocytometry and automated cell counting). FIM-based methods may be advantageous over conventional cell methods for determining total cell concentration and cell viability, as FIM measures much larger sample volumes, does not require labeling, is less laborious and provides images of individual cells.

  13. Compressive Sampling based Image Coding for Resource-deficient Visual Communication.

    PubMed

    Liu, Xianming; Zhai, Deming; Zhou, Jiantao; Zhang, Xinfeng; Zhao, Debin; Gao, Wen

    2016-04-14

    In this paper, a new compressive sampling based image coding scheme is developed to achieve competitive coding efficiency at lower encoder computational complexity, while supporting error resilience. This technique is particularly suitable for visual communication with resource-deficient devices. At the encoder, compact image representation is produced, which is a polyphase down-sampled version of the input image; but the conventional low-pass filter prior to down-sampling is replaced by a local random binary convolution kernel. The pixels of the resulting down-sampled pre-filtered image are local random measurements and placed in the original spatial configuration. The advantages of local random measurements are two folds: 1) preserve high-frequency image features that are otherwise discarded by low-pass filtering; 2) remain a conventional image and can therefore be coded by any standardized codec to remove statistical redundancy of larger scales. Moreover, measurements generated by different kernels can be considered as multiple descriptions of the original image and therefore the proposed scheme has the advantage of multiple description coding. At the decoder, a unified sparsity-based soft-decoding technique is developed to recover the original image from received measurements in a framework of compressive sensing. Experimental results demonstrate that the proposed scheme is competitive compared with existing methods, with a unique strength of recovering fine details and sharp edges at low bit-rates.

  14. Quality assessment of internet pharmaceutical products using traditional and non-traditional analytical techniques.

    PubMed

    Westenberger, Benjamin J; Ellison, Christopher D; Fussner, Andrew S; Jenney, Susan; Kolinski, Richard E; Lipe, Terra G; Lyon, Robbe C; Moore, Terry W; Revelle, Larry K; Smith, Anjanette P; Spencer, John A; Story, Kimberly D; Toler, Duckhee Y; Wokovich, Anna M; Buhse, Lucinda F

    2005-12-08

    This work investigated the use of non-traditional analytical methods to evaluate the quality of a variety of pharmaceutical products purchased via internet sites from foreign sources and compared the results with those obtained from conventional quality assurance methods. Traditional analytical techniques employing HPLC for potency, content uniformity, chromatographic purity and drug release profiles were used to evaluate the quality of five selected drug products (fluoxetine hydrochloride, levothyroxine sodium, metformin hydrochloride, phenytoin sodium, and warfarin sodium). Non-traditional techniques, such as near infrared spectroscopy (NIR), NIR imaging and thermogravimetric analysis (TGA), were employed to verify the results and investigate their potential as alternative testing methods. Two of 20 samples failed USP monographs for quality attributes. The additional analytical methods found 11 of 20 samples had different formulations when compared to the U.S. product. Seven of the 20 samples arrived in questionable containers, and 19 of 20 had incomplete labeling. Only 1 of the 20 samples had final packaging similar to the U.S. products. The non-traditional techniques complemented the traditional techniques used and highlighted additional quality issues for the products tested. For example, these methods detected suspect manufacturing issues (such as blending), which were not evident from traditional testing alone.

  15. Area estimation using multiyear designs and partial crop identification

    NASA Technical Reports Server (NTRS)

    Sielken, R. L., Jr.

    1984-01-01

    Statistical procedures were developed for large area assessments using both satellite and conventional data. Crop acreages, other ground cover indices, and measures of change were the principal characteristics of interest. These characteristics are capable of being estimated from samples collected possibly from several sources at varying times, with different levels of identification. Multiyear analysis techniques were extended to include partially identified samples; the best current year sampling design corresponding to a given sampling history was determined; weights reflecting the precision or confidence in each observation were identified and utilized, and the variation in estimates incorporating partially identified samples were quantified.

  16. Microdialysis Monitoring of CSF Parameters in Severe Traumatic Brain Injury Patients: A Novel Approach

    PubMed Central

    Thelin, Eric P.; Nelson, David W.; Ghatan, Per Hamid; Bellander, Bo-Michael

    2014-01-01

    Background: Neuro-intensive care following traumatic brain injury (TBI) is focused on preventing secondary insults that may lead to irreversible brain damage. Microdialysis (MD) is used to detect deranged cerebral metabolism. The clinical usefulness of the MD is dependent on the regional localization of the MD catheter. The aim of this study was to analyze a new method of continuous cerebrospinal fluid (CSF) monitoring using the MD technique. The method was validated using conventional laboratory analysis of CSF samples. MD-CSF and regional MD-Brain samples were correlated to patient outcome. Materials and Methods: A total of 14 patients suffering from severe TBI were analyzed. They were monitored using (1) a MD catheter (CMA64-iView, n = 7448 MD samples) located in a CSF-pump connected to the ventricular drain and (2) an intraparenchymal MD catheter (CMA70, n = 8358 MD samples). CSF-lactate and CSF-glucose levels were monitored and were compared to MD-CSF samples. MD-CSF and MD-Brain parameters were correlated to favorable (Glasgow Outcome Score extended, GOSe 6–8) and unfavorable (GOSe 1–5) outcome. Results: Levels of glucose and lactate acquired with the CSF-MD technique could be correlated to conventional levels. The median MD recovery using the CMA64 catheter in CSF was 0.98 and 0.97 for glucose and lactate, respectively. Median MD-CSF (CMA 64) lactate (p = 0.0057) and pyruvate (p = 0.0011) levels were significantly lower in the favorable outcome group compared to the unfavorable group. No significant difference in outcome was found using the lactate:pyruvate ratio (LPR), or any of the regional MD-Brain monitoring in our analyzed cohort. Conclusion: This new technique of global MD-CSF monitoring correlates with conventional CSF levels of glucose and lactate, and the MD recovery is higher than previously described. Increase in lactate and pyruvate, without any effect on the LPR, correlates to unfavorable outcome, perhaps related to the presence of erythrocytes in the CSF. PMID:25228896

  17. Utility of the summation chromatographic peak integration function to avoid manual reintegrations in the analysis of targeted analytes

    USDA-ARS?s Scientific Manuscript database

    As sample preparation and analytical techniques have improved, data handling has become the main limitation in automated high-throughput analysis of targeted chemicals in many applications. Conventional chromatographic peak integration functions rely on complex software and settings, but untrustwor...

  18. Application of microwave digestion to the analysis of peat

    USGS Publications Warehouse

    Papp, C.S.E.; Fischer, L.B.

    1987-01-01

    A microwave digestion technique for the dissolution of peat is described and compared with a dry ashing method and a nitric - perchloric - hydrofluoric acid wet digestion. Peat samples with different organic matter contents were used and Ca, Mg, Fe, AI, Na, K, Mn, Zn, Cu and Li were determined by atomic absoprtion spectrometry. The results obtained using the three dissolution techniques were in good agreement. The microwave method has the advantage of digesting the samples in less than 2 h and uses less acid than the conventional wet digestion method. Keeping the volume of the acid mixture as small as possible minimises contamination and leads to lower blank values.

  19. Analysis of bacteria on steel surfaces using reflectance micro-Fourier transform infrared spectroscopy.

    PubMed

    Ojeda, Jesús J; Romero-González, María E; Banwart, Steven A

    2009-08-01

    Reflectance micro-Fourier transform infrared (FT-IR) analysis has been applied to characterize biofilm formation of Aquabacterium commune, a common microorganism present on drinking water distribution systems, onto the increasingly popular pipe material stainless steel EN1.4307. The applicability of the reflectance micro-FT-IR technique for analyzing the bacterial functional groups is discussed, and the results are compared to spectra obtained using more conventional FT-IR techniques: transmission micro-FT-IR, attenuated transmitted reflectance (ATR), and KBr pellets. The differences between the infrared spectra of wet and dried bacteria, as well as free versus attached bacteria, are also discussed. The spectra obtained using reflectance micro-FT-IR spectroscopy were comparable to those obtained using other FT-IR techniques. The absence of sample preparation, the potential to analyze intact samples, and the ability to characterize opaque and thick samples without the need to transfer the bacterial samples to an infrared transparent medium or produce a pure culture were the main advantages of reflectance micro-FT-IR spectroscopy.

  20. Detection of hazardous pollutants in chrome-tanned leather using locally developed laser-induced breakdown spectrometer.

    PubMed

    Nasr, M M; Gondal, Mohammed Asharf; Seddigi, Z S

    2011-04-01

    Highly toxic contaminants like Cr, As, and Pb were detected in chrome-tanning process of animal skin to produce leather by applying locally developed laser-induced breakdown spectrometer. An Nd-YAG laser with 1,064 nm wavelength was focused on the surface of leather samples (natural and manufactured) to generate a plasma spark and spectrally resolved spectra were used for identification and quantification of contaminants. The leather samples were collected from a tannery located in industrial cities of Riyadh and Jeddah, Saudi Arabia. The study was carried out on fully, half manufactured (wet blue leather), and natural hide (skin). To the best of our knowledge, this is the first attempt where laser-induced breakdown spectroscopy (LIBS) technique has been applied for the analysis of leather before and after tanning process. The maximum concentration of different elements of environmental significance like chromium, lead, arsenic, sulfur, magnesium were 199, 289, 31, 38, and 39 ppm, respectively, in one of the manufactured leather samples. The limit of detection (LOD) of our LIBS system for chromium, lead, arsenic, sulfur, and magnesium were 2, 3, 1.5,7, and 3 ppm, respectively. The safe permissible limit for tanned leather for highly toxic elements like chromium, lead, and arsenic are 1, 0.5, 0.01 ppm, respectively, as prescribed in Environmental Regulation Standards for Saudi Industries set by Royal Commission Jubail, Saudi Arabia. The LIBS technique is superior to other conventional techniques like ICP or atomic absorption that a little or no sample preparation is required, no chemicals are needed, multi-elemental analysis is possible for all kinds of samples (natural and anthropogenic materials), microgram of sample is essential, and LIBS could be applied for remote analysis. It is highly selective and sensitivity higher than ICP, and as no sample and chemicals are required, it is cost effective for multi-sample analysis per unit time as compared with other conventional techniques. The concentration of some toxic elements (Cr, Pb, As) is much higher than the safe permissible limits set by Occupational Safety and Health Administration in USA or Saudi environmental regulatory agencies. Results obtained with our LIBS systems were in close agreement with the results obtained using other standard analytical technique such as the inductively coupled plasma atomic emission spectroscopy.

  1. Application of image flow cytometry for the characterization of red blood cell morphology

    NASA Astrophysics Data System (ADS)

    Pinto, Ruben N.; Sebastian, Joseph A.; Parsons, Michael; Chang, Tim C.; Acker, Jason P.; Kolios, Michael C.

    2017-02-01

    Red blood cells (RBCs) stored in hypothermic environments for the purpose of transfusion have been documented to undergo structural and functional changes over time. One sign of the so-called RBC storage lesion is irreversible damage to the cell membrane. Consequently, RBCs undergo a morphological transformation from regular, deformable biconcave discocytes to rigid spheroechinocytes. The spherically shaped RBCs lack the deformability to efficiently enter microvasculature, thereby reducing the capacity of RBCs to oxygenate tissue. Blood banks currently rely on microscope techniques that include fixing, staining and cell counting in order to morphologically characterize RBC samples; these methods are labor intensive and highly subjective. This study presents a novel, high-throughput RBC morphology characterization technique using image flow cytometry (IFC). An image segmentation template was developed to process 100,000 images acquired from the IFC system and output the relative spheroechinocyte percentage. The technique was applied on samples extracted from two blood bags to monitor the morphological changes of the RBCs during in vitro hypothermic storage. The study found that, for a given sample of RBCs, the IFC method was twice as fast in data acquisition, and analyzed 250-350 times more RBCs than the conventional method. Over the lifespan of the blood bags, the mean spheroechinocyte population increased by 37%. Future work will focus on expanding the template to segregate RBC images into more subpopulations for the validation of the IFC method against conventional techniques; the expanded template will aid in establishing quantitative links between spheroechinocyte increase and other RBC storage lesion characteristics.

  2. Flexible scintillator autoradiography for tumor margin inspection using 18F-FDG

    NASA Astrophysics Data System (ADS)

    Vyas, K. N.; Grootendorst, M.; Mertzanidou, T.; Macholl, S.; Stoyanov, D.; Arridge, S. R.; Tuch, D. S.

    2018-03-01

    Autoradiography potentially offers high molecular sensitivity and spatial resolution for tumor margin estimation. However, conventional autoradiography requires sectioning the sample which is destructive and labor-intensive. Here we describe a novel autoradiography technique that uses a flexible ultra-thin scintillator which conforms to the sample surface. Imaging with the flexible scintillator enables direct, high-resolution and high-sensitivity imaging of beta particle emissions from targeted radiotracers. The technique has the potential to identify positive tumor margins in fresh unsectioned samples during surgery, eliminating the processing time demands of conventional autoradiography. We demonstrate the feasibility of the flexible autoradiography approach to directly image the beta emissions from radiopharmaceuticals using lab experiments and GEANT-4 simulations to determine i) the specificity for 18F compared to 99mTc-labeled tracers ii) the sensitivity to detect signal from various depths within the tissue. We found that an image resolution of 1.5 mm was achievable with a scattering background and we estimate a minimum detectable activity concentration of 0.9 kBq/ml for 18F. We show that the flexible autoradiography approach has high potential as a technique for molecular imaging of tumor margins using 18F-FDG in a tumor xenograft mouse model imaged with a radiation-shielded EMCCD camera. Due to the advantage of conforming to the specimen, the flexible scintillator showed significantly better image quality in terms of tumor signal to whole-body background noise compared to rigid and optimally thick CaF2:Eu and BC400. The sensitivity of the technique means it is suitable for clinical translation.

  3. Coniferous forest classification and inventory using Landsat and digital terrain data

    NASA Technical Reports Server (NTRS)

    Franklin, J.; Logan, T. L.; Woodcock, C. E.; Strahler, A. H.

    1986-01-01

    Machine-processing techniques were used in a Forest Classification and Inventory System (FOCIS) procedure to extract and process tonal, textural, and terrain information from registered Landsat multispectral and digital terrain data. Using FOCIS as a basis for stratified sampling, the softwood timber volumes of the Klamath National Forest and Eldorado National Forest were estimated within standard errors of 4.8 and 4.0 percent, respectively. The accuracy of these large-area inventories is comparable to the accuracy yielded by use of conventional timber inventory methods, but, because of automation, the FOCIS inventories are more rapid (9-12 months compared to 2-3 years for conventional manual photointerpretation, map compilation and drafting, field sampling, and data processing) and are less costly.

  4. Effect of three extraction techniques on submitochondrial particle and Microtox bioassays for airborne particulate matter.

    PubMed

    Torres-Pérez, Mónica I; Jiménez-Velez, Braulio D; Mansilla-Rivera, Imar; Rodríguez-Sierra, Carlos J

    2005-03-01

    The effect that three extraction techniques (e.g., Soxhlet, ultrasound and microwave-assisted extraction) have on the toxicity, as measured by submitochondrial particle (SMP) and Microtox assays, of organic extracts was compared from three sources of airborne particulate matter (APM). The extraction technique influenced the toxicity response of APM extracts and it was dependent on the bioassay method, and APM sample source. APM extracts from microwave-assisted extraction (MAE) were similar or more toxic than the conventional extraction techniques of Soxhlet and ultrasound, thus, providing an alternate extraction method. The microwave extraction technique has the advantage of using less solvent volume, less extraction time, and the capacity to simultaneously extract twelve samples. The ordering of APM toxicity was generally urban dust > diesel dust > PM10 (particles with diameter < 10 microm), thus, reflecting different chemical composition of the samples. This study is the first to report the suitability of two standard in-vitro bioassays for the future toxicological characterization of APM collected from Puerto Rico, with the SMP generally showing better sensitivity to the well-known Microtox bioassay.

  5. Glucosinolates profile and antioxidant capacity of Romanian Brassica vegetables obtained by organic and conventional agricultural practices.

    PubMed

    Vicas, Simona I; Teusdea, Alin C; Carbunar, Mihai; Socaci, Sonia A; Socaciu, Carmen

    2013-09-01

    The profile of glucosinolates in relation to the antioxidant capacity of five Brassica vegetables (Broccoli, Cauliflower, Kohlrabi, White and Red Cabbage) grown by organic and conventional agricultural practices in Transylvania region-Romania, were determined and compared. The qualitative and quantitative compositions of glucosinolates were determined by HPLC-PDA technique. The antioxidant capacity was comparatively determined by ABTS, DPPH, FRAP and Folin-Ciocalteu assays. The highest glucosinolates levels were found in the Broccoli samples grown under conventional practices (14.24 μmol/g dry weight), glucoraphanin, glucobrassicin and neo-glucobrassicin being the major components. The total glucosinolates content was similar in Kohlrabi and Cauliflower (4.89 and 4.84 μmol/g dry weight, respectively), the indolyl glucosinolates were predominant in Kohlrabi, while the aliphatic derivatives (sinigrin and glucoiberin) were major in Cauliflower. In Cabbage samples, the aliphatic glucosinolates were predominat against indolyl derivatives, glucoraphanin and glucoiberin being the main ones in Red Cabbage. The principal component analysis was applied to discriminate among conventional and organic samples and demonstrated non-overlaps between these two agricultural practices. Meanwhile it was shown that glucosinolates may represent appropriate molecular markers of Brassica vegetables, their antioxidant capacity being higher in organic crops, without significant differences among different Brassica varieties.

  6. Comparison of marginal accuracy of castings fabricated by conventional casting technique and accelerated casting technique: an in vitro study.

    PubMed

    Reddy, S Srikanth; Revathi, Kakkirala; Reddy, S Kranthikumar

    2013-01-01

    Conventional casting technique is time consuming when compared to accelerated casting technique. In this study, marginal accuracy of castings fabricated using accelerated and conventional casting technique was compared. 20 wax patterns were fabricated and the marginal discrepancy between the die and patterns were measured using Optical stereomicroscope. Ten wax patterns were used for Conventional casting and the rest for Accelerated casting. A Nickel-Chromium alloy was used for the casting. The castings were measured for marginal discrepancies and compared. Castings fabricated using Conventional casting technique showed less vertical marginal discrepancy than the castings fabricated by Accelerated casting technique. The values were statistically highly significant. Conventional casting technique produced better marginal accuracy when compared to Accelerated casting. The vertical marginal discrepancy produced by the Accelerated casting technique was well within the maximum clinical tolerance limits. Accelerated casting technique can be used to save lab time to fabricate clinical crowns with acceptable vertical marginal discrepancy.

  7. [Surface characteristics of the acrylic resins according to the polishing methods].

    PubMed

    Vitalariu, Anca Mihaela; Lazăr, Lenuţa; Buruiană, Tinca; Diaconu, Diana; Tatarciuc, Monica Silvia

    2011-01-01

    The objective of this study was to evaluate the effect of the polishing technique and glazing on the porosity of the dental resins. The studied resins were: Castapress/Vertex, Prothyl Hot/Zermack, Rapid Simplified/Vertex, Duracryl Plus/Spofa Dental, Vertex-Soft/Vertex, Superacryl Plus/Spofa Dental. Thirty specimens, five for every resin, of 50/25/2 cm in size were done. One surface of each sample was polished with extrahard tungsten carbide burs, the other surface being polished with extrahard extrafine and diamond burs. The final polishing was done using a conventional method: pumice, water and lathe bristle brush for 90 seconds, 1500 rpm and soft leather polishing wheel for 90 seconds, 3000 rpm. Twenty surfaces were glazed after polishing with Glaze/Bosworth. Vertex Soft specimens were not polished because this is a resilient material. Surface porosity of the acrylic resin specimens was measured by optical microscopy. The lowest porosity was obtained by conventional polishing combined with glazing techniques. No differences between glazed and non/glazed self-curing resin specimens were noticed, but there were differences between self-curing and heat-curing resins. Conventional lathe polishing method is an effective and reliable technique for polishing dental resins. Specimens of self-curing resin had a higher porosity than heat curing resin following the same surface treatment. Higher surface smoothness was obtained by conventional lathe polishing completed by glazing.

  8. Comparison of conventional twist drill protocol and piezosurgery for implant insertion: an ex vivo study on different bone types.

    PubMed

    Sagheb, Keyvan; Kumar, Vinay V; Azaripour, Adriano; Walter, Christian; Al-Nawas, Bilal; Kämmerer, Peer W

    2017-02-01

    The aim of this ex vivo study was to compare implant insertion procedures using piezosurgery and conventional drilling in different qualities of bone. Implant bed preparation time, generated heat, and primary implant stability were analyzed. Fresh ex vivo porcine bone block samples (cancellous, mixed, and cortical bone) were obtained. The bone quality was quantified by ultrasound transmission velocity (UTV). Each bone sample received three implants of the same diameter using each of the techniques of piezosurgery and conventional twist drills. Time for preparation was taken and the temperature while performing the osteotomy was measured using infrared spectroscopy. The primary implant stability after osteotomy was measured using resonance frequency analysis (RFA) and extrusion torque (ET). ANOVA with post hoc Tukey test was carried out to compare the values for the three different groups. The UTV values strongly correlated with the density of the bone samples. There was a significant increase in time (threefold, P < 0.05 [302 s vs. 122 s in cortical bone]) but no difference in the temperature for the piezo group (~37°C in cortical bone). Regardless of the osteotomy technique, there was a statistically significant increase in RFA and ET values in implants inserted in cancellous bone (RFA: piezo 77, drill 76; ET: piezo 22, drill 21), mixed bone (RFA: piezo 85, drill 86; ET: piezo 105, drill 61), and cortical bone (RFA: piezo 90, drill 87; ET piezo 184, drill 79) samples, respectively (P < 0.05). In between the different osteotomy groups, there was no difference in the RFA values but significant higher ET values in mixed/cortical bone samples in favor for the piezosurgery group. Piezosurgery and conventional implant bed drilling procedure do have similar mechanical outcomes regarding primary stability with high RFA values, but the preparation does need more time for piezosurgery group, so that piezosurgery might be a valuable tool in only very specific cases for implant bed preparation. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Comparison of PCR, culturing and Pap smear microscopy for accurate diagnosis of genital Actinomyces.

    PubMed

    Kaya, Dilek; Demirezen, Şayeste; Hasçelik, Gülşen; Gülmez Kivanç, Dolunay; Beksaç, Mehmet Sinan

    2013-05-01

    Members of the genus Actinomyces, Gram-positive, non-spore-forming anaerobic bacteria, are normal inhabitants of the mucosal surfaces of the oral, gastrointestinal and genital tracts. Identification of these bacteria using conventional methods is generally difficult because of their complex transport and growth requirements and their fastidious and slow-growing nature. However, in recent years, the advancement of molecular techniques has provided much improved identification and differentiation of closely related Actinomyces species. The aim of the present study was to evaluate the efficacy of the PCR technique in the diagnosis of genital Actinomyces in comparison with culturing and Papanicolaou (Pap) smear microscopy. Multiple sampling was conducted from 200 women using smear microscopy, culturing and PCR. Cyto-brushes were smeared on glass slides and stained using the routine Pap technique. Culturing was performed from a sterile swab, and Actinomyces were determined using the BBL Crystal ANR ID kit. PCR was performed from a second swab, and the Actinomyces type was determined using type-specific primers designed in our laboratory. Only one vaginal fluid sample (0.5%) revealed Actinomyces-like organisms on Pap smear examination. Actinomyces were detected in nine samples (4.5%) using the BBL Crystal ANR ID kit. Using PCR, eight samples (4%) were found positive for Actinomyces. No specimens that gave positive results by Pap smear microscopy and culturing could be confirmed by PCR. Pap smear microscopy and culturing were both found to have zero sensitivity for Actinomyces. PCR appears to be a sensitive and reliable diagnostic method for the detection of Actinomyces, which are difficult to cultivate from genital samples. PCR can be used for diagnostic confirmation in cases diagnosed by conventional methods, to prevent false-positive results.

  10. Comparative Evaluation of Marginal and Internal Gap of Co-Cr Copings Fabricated from Conventional Wax Pattern, 3D Printed Resin Pattern and DMLS Tech: An In Vitro Study.

    PubMed

    Bhaskaran, Eswaran; Azhagarasan, N S; Miglani, Saket; Ilango, T; Krishna, G Phani; Gajapathi, B

    2013-09-01

    Accuracy of the fit of the restoration has always remained as one of the primary factors in determining success of the restoration. A well fitting restoration needs to be accurate both along its margins and internal surface. This study was conducted to comparatively evaluate the marginal gap and internal gap of cobalt-chromium (Co-Cr) copings fabricated by conventional casting procedures and with direct metal laser sintering (DMLS) technique. Among the total of 30 test samples 10 cast copings were made from inlay casting wax and 10 from 3D printed resin pattern. 10 copings were obtained from DMLS technique. All the 30 test samples were then cemented sequentially on stainless steel model using pressure indicating paste and evaluated for vertical marginal gap in 8 predetermined reference areas. All copings were then removed and partially sectioned and cemented sequentially on same master model for evaluation of internal gap at 4 predetermined reference areas. Both marginal gap and internal gap were measured in microns using video measuring system (VMS2010F). The results obtained for both marginal and internal gap were statistically analyzed and the values fall within the clinically acceptable range. The DMLS technique had an edge over the other two techniques used, as it exhibited minimal gap in the marginal region which is an area of chief concern.

  11. Assessment of Response Surface Models using Independent Confirmation Point Analysis

    NASA Technical Reports Server (NTRS)

    DeLoach, Richard

    2010-01-01

    This paper highlights various advantages that confirmation-point residuals have over conventional model design-point residuals in assessing the adequacy of a response surface model fitted by regression techniques to a sample of experimental data. Particular advantages are highlighted for the case of design matrices that may be ill-conditioned for a given sample of data. The impact of both aleatory and epistemological uncertainty in response model adequacy assessments is considered.

  12. Evaluation of counting methods for oceanic radium-228

    NASA Astrophysics Data System (ADS)

    Orr, James C.

    1988-07-01

    Measurement of open ocean 228Ra is difficult, typically requiring at least 200 L of seawater. The burden of collecting and processing these large-volume samples severely limits the widespread use of this promising tracer. To use smaller-volume samples, a more sensitive means of analysis is required. To seek out new and improved counting method(s), conventional 228Ra counting methods have been compared with some promising techniques which are currently used for other radionuclides. Of the conventional methods, α spectrometry possesses the highest efficiency (3-9%) and lowest background (0.0015 cpm), but it suffers from the need for complex chemical processing after sampling and the need to allow about 1 year for adequate ingrowth of 228Th granddaughter. The other two conventional counting methods measure the short-lived 228Ac daughter while it remains supported by 228Ra, thereby avoiding the complex sample processing and the long delay before counting. The first of these, high-resolution γ spectrometry, offers the simplest processing and an efficiency (4.8%) comparable to α spectrometry; yet its high background (0.16 cpm) and substantial equipment cost (˜30,000) limit its widespread use. The second no-wait method, β-γ coincidence spectrometry, also offers comparable efficiency (5.3%), but it possesses both lower background (0.0054 cpm) and lower initial cost (˜12,000). Three new (i.e., untried for 228Ra) techniques all seem to promise about a fivefold increase in efficiency over conventional methods. By employing liquid scintillation methods, both α spectrometry and β-γ coincidence spectrometry can improve their counter efficiency while retaining low background. The third new 228Ra counting method could be adapted from a technique which measures 224Ra by 220Rn emanation. After allowing for ingrowth and then counting for the 224Ra great-granddaughter, 228Ra could be back calculated, thereby yielding a method with high efficiency, where no sample processing is required. The efficiency and background of each of the three new methods have been estimated and are compared with those of the three methods currently employed to measure oceanic 228Ra. From efficiency and background, the relative figure of merit and the detection limit have been determined for each of the six counters. These data suggest that the new counting methods have the potential to measure most 228Ra samples with just 30 L of seawater, to better than 5% precision. Not only would this reduce the time, effort, and expense involved in sample collection, but 228Ra could then be measured on many small-volume samples (20-30 L) previously collected with only 226Ra in mind. By measuring 228Ra quantitatively on such small-volume samples, three analyses (large-volume 228Ra, large-volume 226Ra, and small-volume 226Ra) could be reduced to one, thereby dramatically improving analytical precision.

  13. A Computational Approach to Qualitative Analysis in Large Textual Datasets

    PubMed Central

    Evans, Michael S.

    2014-01-01

    In this paper I introduce computational techniques to extend qualitative analysis into the study of large textual datasets. I demonstrate these techniques by using probabilistic topic modeling to analyze a broad sample of 14,952 documents published in major American newspapers from 1980 through 2012. I show how computational data mining techniques can identify and evaluate the significance of qualitatively distinct subjects of discussion across a wide range of public discourse. I also show how examining large textual datasets with computational methods can overcome methodological limitations of conventional qualitative methods, such as how to measure the impact of particular cases on broader discourse, how to validate substantive inferences from small samples of textual data, and how to determine if identified cases are part of a consistent temporal pattern. PMID:24498398

  14. Conserving biodiversity and ecosystem function through limited development: an empirical evaluation.

    PubMed

    Milder, Jeffrey C; Lassoie, James P; Bedford, Barbara L

    2008-02-01

    Suburban, exurban, and rural development in the United States consumes nearly 1 million hectares of land per year and is a leading threat to biodiversity. In response to this threat, conservation development has been advanced as a way to combine land development and land conservation while providing functional protection for natural resources. Yet, although conservation development techniques have been in use for decades, there have been few critical evaluations of their conservation effectiveness. We addressed this deficiency by assessing the conservation outcomes of one type of conservation development project: conservation and limited development projects (CLDPs). Conducted by land trusts, landowners, and developers, CLDPs use revenue from limited development to finance the protection of land and natural resources. We compared a sample of 10 CLDPs from the eastern United States with their respective baseline scenarios (conventional development) and with a sample of conservation subdivisions--a different conservation development technique characterized by higher-density development. To measure conservation success, we created an evaluation method containing eight indicators that quantify project impacts to terrestrial and aquatic ecosystems at the site and in the surrounding landscape. The CLDPs protected and managed threatened natural resources including rare species and ecological communities. In terms of conservation benefits, the CLDPs significantly outperformed their respective baseline scenarios and the conservation subdivisions. These results imply that CLDPs can offer a low-impact alternative to conventional development and a low-cost method for protecting land when conventional conservation techniques are too expensive. In addition, our evaluation method demonstrates how planners and developers can incorporate appropriate ecological considerations when designing, reviewing, and evaluating conservation development projects.

  15. Water-based gas purge microsyringe extraction coupled with liquid chromatography for determination of alkylphenols from sea food Laminaria japonica Aresh.

    PubMed

    Yang, Cui; Zhao, Jinhua; Wang, Juan; Yu, Hongling; Piao, Xiangfan; Li, Donghao

    2013-07-26

    A novel organic solvent-free mode of gas purge microsyringe extraction, termed water-based gas purge microsyringe extraction, was developed. This technique can directly extract target compounds in wet samples without any drying process. Parameters affecting the extraction efficiency were investigated. Under optimal extraction conditions, the recoveries of alkylphenols were between 87.6 and 105.8%, and reproducibility was between 5.2 and 12.1%. The technique was also used to determine six kinds of alkylphenols (APs) from samples of Laminaria japonica Aresh. The OP and NP were detected in all the samples, and concentrations ranged from 26.0 to 54.5ngg(-1) and 45.0-180.4ngg(-1), respectively. The 4-n-butylphenol was detected in only one sample and its concentration was very low. Other APs were not detected in L. japonica Aresh samples. The experimental results demonstrated that the technique is fast, simple, non-polluting, allows for quantitative extraction, and a drying process was not required for wet samples. Since only aqueous solution and a conventional microsyringe were used, this technique proved affordable, efficient, and convenient for the extraction of volatile and semivolatile ionizable compounds. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Pattern recognition applied to mineral characterization of Brazilian coffees and sugar-cane spirits

    NASA Astrophysics Data System (ADS)

    Fernandes, Andréa P.; Santos, Mirian C.; Lemos, Sherlan G.; Ferreira, Márcia M. C.; Nogueira, Ana Rita A.; Nóbrega, Joaquim A.

    2005-06-01

    Aluminium, Ca, Cu, Fe, K, Mg, Mn, Na, Pb, S, Se, Si, Sn, Sr, and Zn were determined in coffee and sugar-cane spirit (cachaça) samples by axial viewing inductively coupled plasma optical emission spectrometry (ICP OES). Pattern recognition techniques such as principal component analysis and cluster analysis were applied to data sets in order to characterize samples with relation to their geographical origin and production mode (industrial or homemade and organically or conventionally produced). Attempts to correlate metal ion content with the geographical origin of coffee and the production mode (organic or conventional) of cachaça were not successful. Some differentiation was suggested for the geographical origin of cachaça of three regions (Northeast, Central, and South), and for coffee samples, related to the production mode. Clear separations were only obtained for differentiation between industrial and homemade cachaças, and between instant soluble and roasted coffees.

  17. Extraction mechanism of ultrasound assisted extraction and its effect on higher yielding and purity of artemisinin crystals from Artemisia annua L. leaves.

    PubMed

    Chemat, Smain; Aissa, Abdallah; Boumechhour, Abdenour; Arous, Omar; Ait-Amar, Hamid

    2017-01-01

    This study proposes an ultrasound-horn system for the extraction of a natural active compound "artemisinin" from Artemisia annua L. leaves as an alternative to hot maceration technique. Ultrasound leaching improves artemisinin recovery at all temperatures where only ten minutes is required to recover 70% (4.42mgg -1 ) compared to 60min of conventional hot leaching for the same yield. For instance, ultrasound treatment at 30°C produced a higher yield than the one obtained by conventional maceration at 40°C. Kinetic study suggests that the extraction pattern can be assimilated, during the first ten minutes, to a first order steady state, from which activation energy calculations revealed that each gram of artemisinin required 7.38kJ in ultrasound versus 10.3kJ in the conventional system. Modeling results indicate the presence of two extraction stages, a faster stage with a diffusion coefficient of 19×10 -5 cm 2 min -1 for ultrasound technique at 40°C, seven times higher than the conventional one; and a second deceleration stage similar for both techniques with diffusion coefficient ranging from 1.7 to 3.1×10 -5 cm 2 min -1 . It is noted that the efficient ultrasound extraction potential implies extraction of higher amount of co-metabolites so low artemisinin crystal purity is engendered but a combination with a purification step using activated charcoal and celite adsorbents produced crystals with comparable purity for conventional and ultrasound samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Annealing of Co-Cr dental alloy: effects on nanostructure and Rockwell hardness

    PubMed Central

    Soylu, Elif Hilal; İde, Semra; Kılıç, Selim; Sipahi, Cumhur; Pişkin, Bulent; Gökçe, Hasan Suat

    2013-01-01

    PURPOSE The aim of the study was to evaluate the effect of annealing on the nanostructure and hardness of Co-Cr metal ceramic samples that were fabricated with a direct metal laser sintering (DMLS) technique. MATERIALS AND METHODS Five groups of Co-Cr dental alloy samples were manufactured in a rectangular form measuring 4 × 2 × 2 mm. Samples fabricated by a conventional casting technique (Group I) and prefabricated milling blanks (Group II) were examined as conventional technique groups. The DMLS samples were randomly divided into three groups as not annealed (Group III), annealed in argon atmosphere (Group IV), or annealed in oxygen atmosphere (Group V). The nanostructure was examined with the small-angle X-ray scattering method. The Rockwell hardness test was used to measure the hardness changes in each group, and the means and standard deviations were statistically analyzed by one-way ANOVA for comparison of continuous variables and Tukey's HSD test was used for post hoc analysis. P values of <.05 were accepted as statistically significant. RESULTS The general nanostructures of the samples were composed of small spherical entities stacked atop one another in dendritic form. All groups also displayed different hardness values depending on the manufacturing technique. The annealing procedure and environment directly affected both the nanostructure and hardness of the Co-Cr alloy. Group III exhibited a non-homogeneous structure and increased hardness (48.16 ± 3.02 HRC) because the annealing process was incomplete and the inner stress was not relieved. Annealing in argon atmosphere of Group IV not only relieved the inner stresses but also decreased the hardness (27.40 ± 3.98 HRC). The results of fitting function presented that Group IV was the most homogeneous product as the minimum bilayer thickness was measured (7.11 Å). CONCLUSION After the manufacturing with DMLS technique, annealing in argon atmosphere is an essential process for Co-Cr metal ceramic substructures. The dentists should be familiar with the materials that are used in clinic for prosthodontics treatments. PMID:24353888

  19. Dynamic magnetic resonance imaging method based on golden-ratio cartesian sampling and compressed sensing.

    PubMed

    Li, Shuo; Zhu, Yanchun; Xie, Yaoqin; Gao, Song

    2018-01-01

    Dynamic magnetic resonance imaging (DMRI) is used to noninvasively trace the movements of organs and the process of drug delivery. The results can provide quantitative or semiquantitative pathology-related parameters, thus giving DMRI great potential for clinical applications. However, conventional DMRI techniques suffer from low temporal resolution and long scan time owing to the limitations of the k-space sampling scheme and image reconstruction algorithm. In this paper, we propose a novel DMRI sampling scheme based on a golden-ratio Cartesian trajectory in combination with a compressed sensing reconstruction algorithm. The results of two simulation experiments, designed according to the two major DMRI techniques, showed that the proposed method can improve the temporal resolution and shorten the scan time and provide high-quality reconstructed images.

  20. Screening and rapid identification of Campylobacter spp. DNA by FlaA PCR based method on chicken and human fecal samples in Egypt

    USDA-ARS?s Scientific Manuscript database

    Campylobacter is a foodborne pathogen which has a potential public health concern worldwide. Due to discriminatory problems encountered by conventional isolation of Campylobacter spp. and its genetic similarities, rapid molecular techniques for its genetic characterization are useful. In this study,...

  1. Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres

    NASA Technical Reports Server (NTRS)

    Valentin, J. R.

    1989-01-01

    Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan-Cassini entry probe, which is being jointly planned by NASA and the European Space Agency (ESA), might be launched as early as 1994. As in the Pioneer mission, limited time--perhaps only 3-4 h--will be available for the completion of all analyses while the probe descends through the atmosphere. A conventional GC or GC-MS system would be able to analyze no more than two aerosol and two gas samples during the probe's descent. Conventional GC also is limited by the sensitivity of the detector and by the sample volume. For the Titan mission, the sensitivity problems will be worse because the atmospheric pressure at the time of instrument deployment is expected to be < 3 torr. Consequently, the sample volume might not be large enough to satisfy the detector sensitivity requirements. Because of such limitations, alternative GC analysis techniques have been investigated for future NASA missions. Multiplex gas chromatography has been investigated as a possible candidate for chemical analysis within a spacecraft or other restricted environment, and chemical modulators have been developed and used when needed with this technique to reduce the size and weight of the instrumentation. Also, several new multiplex techniques have been developed for use in specific applications.

  2. Split Hopkinson resonant bar test for sonic-frequency acoustic velocity and attenuation measurements of small, isotropic geological samples.

    PubMed

    Nakagawa, Seiji

    2011-04-01

    Mechanical properties (seismic velocities and attenuation) of geological materials are often frequency dependent, which necessitates measurements of the properties at frequencies relevant to a problem at hand. Conventional acoustic resonant bar tests allow measuring seismic properties of rocks and sediments at sonic frequencies (several kilohertz) that are close to the frequencies employed for geophysical exploration of oil and gas resources. However, the tests require a long, slender sample, which is often difficult to obtain from the deep subsurface or from weak and fractured geological formations. In this paper, an alternative measurement technique to conventional resonant bar tests is presented. This technique uses only a small, jacketed rock or sediment core sample mediating a pair of long, metal extension bars with attached seismic source and receiver-the same geometry as the split Hopkinson pressure bar test for large-strain, dynamic impact experiments. Because of the length and mass added to the sample, the resonance frequency of the entire system can be lowered significantly, compared to the sample alone. The experiment can be conducted under elevated confining pressures up to tens of MPa and temperatures above 100 [ordinal indicator, masculine]C, and concurrently with x-ray CT imaging. The described split Hopkinson resonant bar test is applied in two steps. First, extension and torsion-mode resonance frequencies and attenuation of the entire system are measured. Next, numerical inversions for the complex Young's and shear moduli of the sample are performed. One particularly important step is the correction of the inverted Young's moduli for the effect of sample-rod interfaces. Examples of the application are given for homogeneous, isotropic polymer samples, and a natural rock sample. © 2011 American Institute of Physics

  3. Ochratoxigenic fungi associated with green coffee beans (Coffea arabica L.) in conventional and organic cultivation in Brazil.

    PubMed

    de Fátima Rezende, Elisângela; Borges, Josiane Gonçalves; Cirillo, Marcelo Ângelo; Prado, Guilherme; Paiva, Leandro Carlos; Batista, Luís Roberto

    2013-01-01

    The genera Aspergillus comprises species that produce mycotoxins such as aflatoxins, ochratoxins and patulin. These are cosmopolitan species, natural contaminants of agricultural products. In coffee grains, the most important Aspergillus species in terms of the risk of presenting mycotoxins belong to the genera Aspergillus Section Circumdati and Section Nigri. The purpose of this study was to assess the occurrence of isolated ochratoxigenic fungi of coffee grains from organic and conventional cultivation from the South of Minas Gerais, Brazil, as well as to evaluate which farming system presents higher contamination risk by ochratoxin A (OTA) produced by fungi. Thirty samples of coffee grains (Coffea arabica L.) were analysed, being 20 of them of conventional coffee grains and 10 of them organic. The microbiological analysis was done with the Direct Plating Technique in a Dichloran Rose Bengal Chloramphenicol Agar (DRBC) media. The identification was done based on the macro and micro morphological characteristics and on the toxigenic potential with the Plug Agar technique. From the 30 samples analysed, 480 filamentous fungi of the genera Aspergillus of the Circumdati and Nigri Sections were isolated. The ochratoxigenic species identified were: Aspergillus auricoumus, A. ochraceus, A. ostianus, A. niger and A. niger Aggregate. The most frequent species which produces ochratoxin A among the isolated ones was A. ochraceus, corresponding to 89.55%. There was no significant difference regarding the presence of ochratoxigenic A. ochreceus between the conventional and organic cultivation systems, which suggests that the contamination risk is similar for both cultivation systems.

  4. Ochratoxigenic fungi associated with green coffee beans (Coffea arabica L.) in conventional and organic cultivation in Brazil

    PubMed Central

    de Fátima Rezende, Elisângela; Borges, Josiane Gonçalves; Cirillo, Marcelo Ângelo; Prado, Guilherme; Paiva, Leandro Carlos; Batista, Luís Roberto

    2013-01-01

    The genera Aspergillus comprises species that produce mycotoxins such as aflatoxins, ochratoxins and patulin. These are cosmopolitan species, natural contaminants of agricultural products. In coffee grains, the most important Aspergillus species in terms of the risk of presenting mycotoxins belong to the genera Aspergillus Section Circumdati and Section Nigri. The purpose of this study was to assess the occurrence of isolated ochratoxigenic fungi of coffee grains from organic and conventional cultivation from the South of Minas Gerais, Brazil, as well as to evaluate which farming system presents higher contamination risk by ochratoxin A (OTA) produced by fungi. Thirty samples of coffee grains (Coffea arabica L.) were analysed, being 20 of them of conventional coffee grains and 10 of them organic. The microbiological analysis was done with the Direct Plating Technique in a Dichloran Rose Bengal Chloramphenicol Agar (DRBC) media. The identification was done based on the macro and micro morphological characteristics and on the toxigenic potential with the Plug Agar technique. From the 30 samples analysed, 480 filamentous fungi of the genera Aspergillus of the Circumdati and Nigri Sections were isolated. The ochratoxigenic species identified were: Aspergillus auricoumus, A. ochraceus, A. ostianus, A. niger and A. niger Aggregate. The most frequent species which produces ochratoxin A among the isolated ones was A. ochraceus, corresponding to 89.55%. There was no significant difference regarding the presence of ochratoxigenic A. ochreceus between the conventional and organic cultivation systems, which suggests that the contamination risk is similar for both cultivation systems. PMID:24294225

  5. Fabrication and characterization of the organic rectifying junctions by electrolysis

    NASA Astrophysics Data System (ADS)

    Karimov, Khasan; Ahmad, Zubair; Ali, Rashid; Noor, Adnan; Akmal, M.; Najeeb, M. A.; Shakoor, R. A.

    2017-08-01

    Unlike the conventional solution processable deposition techniques, in this study, we propose a novel and economical method for the fabrication of organic rectifying junctions. The solutions of the orange dye, copper phthalocyanine and NaCl were deposited on the surface-type interdigitated silver electrodes using electrolysis technique. Using the current-voltage (I-V) characteristics, the presence of rectifying behavior in the samples has been confirmed. This phenomenon, in principle, can be used for fabrication of the diodes, transistors and memory devices.

  6. Practical uncertainty reduction and quantification in shock physics measurements

    DOE PAGES

    Akin, M. C.; Nguyen, J. H.

    2015-04-20

    We report the development of a simple error analysis sampling method for identifying intersections and inflection points to reduce total uncertainty in experimental data. This technique was used to reduce uncertainties in sound speed measurements by 80% over conventional methods. Here, we focused on its impact on a previously published set of Mo sound speed data and possible implications for phase transition and geophysical studies. However, this technique's application can be extended to a wide range of experimental data.

  7. Gas composition of the January 1983 eruption of Kilauea Volcano, Hawaii

    USGS Publications Warehouse

    Greenland, L.P.

    1984-01-01

    Gas collections were made from a ???900??C vent both by conventional evacuated-bottle/wet-chemical techniques and by manual pumping of flowthrough bottles. The complete analyses suggest an equilibrium assemblage quenched at 1,010??C, about midway between fountain and vent temperatures. I suggest that the very low C S ratio is due to degassing of CO2 during storage of the magma in a shallow reservoir before eruption. The two sampling techniques yielded analytical data in mutual agreement. ?? 1984.

  8. Z-scan measurements using femtosecond continuum generation

    NASA Astrophysics Data System (ADS)

    de Boni, Leonardo; Andrade, Acácio A.; Misoguti, Lino; Mendonça, Cléber R.; Zilio, Sérgio Carlos

    2004-08-01

    We present a single beam Z-scan technique using an intense, broadband, white-light continuum (WLC) beam for the direct measurement of nonlinear absorption spectra. In order to demonstrate the validity of our technique, we compared the results of tetraaniline and Sudan 3 solutions obtained with WLC and conventional single wavelength light sources. Both approaches lead to the same nonlinear spectrum, indicating that the association of the Z-scan technique and the WLC source results in an useful method for the measurement of nonlinear spectra of both absorbing (saturable absorption or reverse saturable absorption) and transparent (two-photon absorption) samples.

  9. Comparison of techniques for detecting antigens of Giardia lamblia and Cryptosporidium parvum in faeces.

    PubMed Central

    Tee, G H; Moody, A H; Cooke, A H; Chiodini, P L

    1993-01-01

    AIM--To compare the use of commercial monoclonal antibody test systems--the Giardia CEL IF test and the Crypto CEL IF test--for the detection of Giardia lamblia and Cryptosporidium parvum antigens in faeces with conventional techniques. METHODS--Sensitivity and specificity were evaluated using preparations of cysts of G lamblia and purified oocysts of C parvum. Evaluation of 59 random faecal samples passing through the Department of Clinical Parasitology, Hospital for Tropical Diseases, London, was carried out for both organisms. RESULTS--The fluorescence staining techniques proved more sensitive than other tests routinely used for diagnosis. PMID:8331181

  10. A 2D spiral turbo-spin-echo technique.

    PubMed

    Li, Zhiqiang; Karis, John P; Pipe, James G

    2018-03-09

    2D turbo-spin-echo (TSE) is widely used in the clinic for neuroimaging. However, the long refocusing radiofrequency pulse train leads to high specific absorption rate (SAR) and alters the contrast compared to conventional spin-echo. The purpose of this work is to develop a robust 2D spiral TSE technique for fast T 2 -weighted imaging with low SAR and improved contrast. A spiral-in/out readout is incorporated into 2D TSE to fully take advantage of the acquisition efficiency of spiral sampling while avoiding potential off-resonance-related artifacts compared to a typical spiral-out readout. A double encoding strategy and a signal demodulation method are proposed to mitigate the artifacts because of the T 2 -decay-induced signal variation. An adapted prescan phase correction as well as a concomitant phase compensation technique are implemented to minimize the phase errors. Phantom data demonstrate the efficacy of the proposed double encoding/signal demodulation, as well as the prescan phase correction and concomitant phase compensation. Volunteer data show that the proposed 2D spiral TSE achieves fast scan speed with high SNR, low SAR, and improved contrast compared to conventional Cartesian TSE. A robust 2D spiral TSE technique is feasible and provides a potential alternative to conventional 2D Cartesian TSE for T 2 -weighted neuroimaging. © 2018 International Society for Magnetic Resonance in Medicine.

  11. Determination of polybrominated diphenyl ethers (PBDEs) in dust samples collected in air conditioning filters of different usage - method development.

    PubMed

    Śmiełowska, M; Zabiegała, B

    2018-06-19

    This study presents the results of studies aimed at the development of an analytical procedure for separation, identification, and determination of PBDEs compounds in dust samples collected from automotive cabin air filters and samples collected from filters installed as part of the air purification system in academic facilities. Ultrasound-assisted dispersive solid phase extraction (UA-dSPE) was found to perform better in terms of extract purification than the conventional SPE technique. GC-EIMS was used for final determination of analytes. The concentrations of PBDEs in car filters ranged from < LOD to 688 ng/g while from < LOD to 247 ng/g in dust from air conditioning filters. BDE-47 and BDE-100 were reported the dominating congeners. The estimated exposure to PBDEs via ingestion of dust from car filters varied from 0.00022 to 0.012 ng/day in toddlers and from 0.000036 to 0.0029 ng/day in adults; dust from air conditioning filters: from 0.017 to 0.25 ng/day in toddlers and from 0.0029 to 0.042 ng/day. In addition, an attempt was made at extracting PBDEs from a dust samples using the matrix solid-phase dispersion (MSPD) technique as a promising alternative to conventional SPE separations. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Method for charging a hydrogen getter

    DOEpatents

    Tracy, C. Edwin; Keyser, Matthew A.; Benson, David K.

    1998-01-01

    A method for charging a sample of either a permanent or reversible getter material with a high concentration of hydrogen while maintaining a base pressure below 10.sup.-4 torr at room temperature involves placing the sample of hydrogen getter material in a chamber, activating the sample of hydrogen getter material, overcharging the sample of getter material through conventional charging techniques to a high concentration of hydrogen, and then subjecting the sample of getter material to a low temperature vacuum bake-out process. Application of the method results in a reversible hydrogen getter which is highly charged to maximum capacities of hydrogen and which concurrently exhibits minimum hydrogen vapor pressures at room temperatures.

  13. Facile synthesis of Li2S-P2S5 glass-ceramics electrolyte with micron range particles for all-solid-state batteries via a low-temperature solution technique (LTST)

    NASA Astrophysics Data System (ADS)

    Choi, Sunho; Lee, Sewook; Park, Jongyeop; Nichols, William T.; Shin, Dongwook

    2018-06-01

    A lithium ion conductive 75Li2Sṡ25P2S5 glass-ceramics electrolyte is, for the first time, successfully synthesized via a new low-temperature solution technique (LTST) and compared to the conventional mechanical-milling technique. Both samples are composed of the highly lithium ion conductive thio-LISICON III analog phase. Due to the uniform dispersion of reactants in an organic liquid, the use of LTST produced significantly smaller and more uniform particle sizes (2.2 ± 1.68 μm) resulting in a 6.5 times higher specific surface area compared to the mechanically-milled sample. A pronounced enhancement of both the rate capability and cyclability is demonstrated for the LTST solid electrolyte sample due to the more intimate contact with the LiCoO2 active material. Furthermore, the LTST sample shows excellent electrochemical stability throughout the potential range of -1 to 5 V. These results suggest that the proposed technique using the optimized LTST process is promising for the preparation of 75Li2Sṡ25P2S5 solid electrolytes for use in advanced Li-ion batteries.

  14. Digital Versus Conventional Impressions in Fixed Prosthodontics: A Review.

    PubMed

    Ahlholm, Pekka; Sipilä, Kirsi; Vallittu, Pekka; Jakonen, Minna; Kotiranta, Ulla

    2018-01-01

    To conduct a systematic review to evaluate the evidence of possible benefits and accuracy of digital impression techniques vs. conventional impression techniques. Reports of digital impression techniques versus conventional impression techniques were systematically searched for in the following databases: Cochrane Central Register of Controlled Trials, PubMed, and Web of Science. A combination of controlled vocabulary, free-text words, and well-defined inclusion and exclusion criteria guided the search. Digital impression accuracy is at the same level as conventional impression methods in fabrication of crowns and short fixed dental prostheses (FDPs). For fabrication of implant-supported crowns and FDPs, digital impression accuracy is clinically acceptable. In full-arch impressions, conventional impression methods resulted in better accuracy compared to digital impressions. Digital impression techniques are a clinically acceptable alternative to conventional impression methods in fabrication of crowns and short FDPs. For fabrication of implant-supported crowns and FDPs, digital impression systems also result in clinically acceptable fit. Digital impression techniques are faster and can shorten the operation time. Based on this study, the conventional impression technique is still recommended for full-arch impressions. © 2016 by the American College of Prosthodontists.

  15. Ultra-high dynamic range electro-optic sampling for detecting millimeter and sub-millimeter radiation

    PubMed Central

    Ibrahim, Akram; Férachou, Denis; Sharma, Gargi; Singh, Kanwarpal; Kirouac-Turmel, Marie; Ozaki, Tsuneyuki

    2016-01-01

    Time-domain spectroscopy using coherent millimeter and sub-millimeter radiation (also known as terahertz radiation) is rapidly expanding its application, owing greatly to the remarkable advances in generating and detecting such radiation. However, many current techniques for coherent terahertz detection have limited dynamic range, thus making it difficult to perform some basic experiments that need to directly compare strong and weak terahertz signals. Here, we propose and demonstrate a novel technique based on cross-polarized spectral-domain interferometry to achieve ultra-high dynamic range electro-optic sampling measurement of coherent millimeter and sub-millimeter radiation. In our scheme, we exploit the birefringence in a single-mode polarization maintaining fiber in order to measure the phase change induced by the electric field of terahertz radiation in the detection crystal. With our new technique, we have achieved a dynamic range of 7 × 106, which is 4 orders of magnitude higher than conventional electro-optic sampling techniques, while maintaining comparable signal-to-noise ratio. The present technique is foreseen to have great impact on experiments such as linear terahertz spectroscopy of optically thick materials (such as aqueous samples) and nonlinear terahertz spectroscopy, where the higher dynamic range is crucial for proper interpretation of experimentally obtained results. PMID:26976363

  16. Ultra-high dynamic range electro-optic sampling for detecting millimeter and sub-millimeter radiation.

    PubMed

    Ibrahim, Akram; Férachou, Denis; Sharma, Gargi; Singh, Kanwarpal; Kirouac-Turmel, Marie; Ozaki, Tsuneyuki

    2016-03-15

    Time-domain spectroscopy using coherent millimeter and sub-millimeter radiation (also known as terahertz radiation) is rapidly expanding its application, owing greatly to the remarkable advances in generating and detecting such radiation. However, many current techniques for coherent terahertz detection have limited dynamic range, thus making it difficult to perform some basic experiments that need to directly compare strong and weak terahertz signals. Here, we propose and demonstrate a novel technique based on cross-polarized spectral-domain interferometry to achieve ultra-high dynamic range electro-optic sampling measurement of coherent millimeter and sub-millimeter radiation. In our scheme, we exploit the birefringence in a single-mode polarization maintaining fiber in order to measure the phase change induced by the electric field of terahertz radiation in the detection crystal. With our new technique, we have achieved a dynamic range of 7 × 10(6), which is 4 orders of magnitude higher than conventional electro-optic sampling techniques, while maintaining comparable signal-to-noise ratio. The present technique is foreseen to have great impact on experiments such as linear terahertz spectroscopy of optically thick materials (such as aqueous samples) and nonlinear terahertz spectroscopy, where the higher dynamic range is crucial for proper interpretation of experimentally obtained results.

  17. An integrated study of earth resources in the state of California using remote sensing techniques

    NASA Technical Reports Server (NTRS)

    Colwell, R. N. (Principal Investigator)

    1975-01-01

    The author has identified the following significant results. A weighted stratified double sample design using hardcopy LANDSAT-1 and ground data was utilized in developmental studies for snow water content estimation. Study results gave a correlation coefficient of 0.80 between LANDSAT sample units estimates of snow water content and ground subsamples. A basin snow water content estimate allowable error was given as 1.00 percent at the 99 percent confidence level with the same budget level utilized in conventional snow surveys. Several evapotranspiration estimation models were selected for efficient application at each level of data to be sampled. An area estimation procedure for impervious surface types of differing impermeability adjacent to stream channels was developed. This technique employs a double sample of 1:125,000 color infrared hightflight transparency data with ground or large scale photography.

  18. X-ray phase-contrast imaging

    NASA Astrophysics Data System (ADS)

    Endrizzi, Marco

    2018-01-01

    X-ray imaging is a standard tool for the non-destructive inspection of the internal structure of samples. It finds application in a vast diversity of fields: medicine, biology, many engineering disciplines, palaeontology and earth sciences are just few examples. The fundamental principle underpinning the image formation have remained the same for over a century: the X-rays traversing the sample are subjected to different amount of absorption in different parts of the sample. By means of phase-sensitive techniques it is possible to generate contrast also in relation to the phase shifts imparted by the sample and to extend the capabilities of X-ray imaging to those details that lack enough absorption contrast to be visualised in conventional radiography. A general overview of X-ray phase contrast imaging techniques is presented in this review, along with more recent advances in this fast evolving field and some examples of applications.

  19. Automated segmentation of synchrotron radiation micro-computed tomography biomedical images using Graph Cuts and neural networks

    NASA Astrophysics Data System (ADS)

    Alvarenga de Moura Meneses, Anderson; Giusti, Alessandro; de Almeida, André Pereira; Parreira Nogueira, Liebert; Braz, Delson; Cely Barroso, Regina; deAlmeida, Carlos Eduardo

    2011-12-01

    Synchrotron Radiation (SR) X-ray micro-Computed Tomography (μCT) enables magnified images to be used as a non-invasive and non-destructive technique with a high space resolution for the qualitative and quantitative analyses of biomedical samples. The research on applications of segmentation algorithms to SR-μCT is an open problem, due to the interesting and well-known characteristics of SR images for visualization, such as the high resolution and the phase contrast effect. In this article, we describe and assess the application of the Energy Minimization via Graph Cuts (EMvGC) algorithm for the segmentation of SR-μCT biomedical images acquired at the Synchrotron Radiation for MEdical Physics (SYRMEP) beam line at the Elettra Laboratory (Trieste, Italy). We also propose a method using EMvGC with Artificial Neural Networks (EMANNs) for correcting misclassifications due to intensity variation of phase contrast, which are important effects and sometimes indispensable in certain biomedical applications, although they impair the segmentation provided by conventional techniques. Results demonstrate considerable success in the segmentation of SR-μCT biomedical images, with average Dice Similarity Coefficient 99.88% for bony tissue in Wistar Rats rib samples (EMvGC), as well as 98.95% and 98.02% for scans of Rhodnius prolixus insect samples (Chagas's disease vector) with EMANNs, in relation to manual segmentation. The techniques EMvGC and EMANNs cope with the task of performing segmentation in images with the intensity variation due to phase contrast effects, presenting a superior performance in comparison to conventional segmentation techniques based on thresholding and linear/nonlinear image filtering, which is also discussed in the present article.

  20. Slow histidine H/D exchange protocol for thermodynamic analysis of protein folding and stability using mass spectrometry.

    PubMed

    Tran, Duc T; Banerjee, Sambuddha; Alayash, Abdu I; Crumbliss, Alvin L; Fitzgerald, Michael C

    2012-02-07

    Described here is a mass spectrometry-based protocol to study the thermodynamic stability of proteins and protein-ligand complexes using the chemical denaturant dependence of the slow H/D exchange reaction of the imidazole C(2) proton in histidine side chains. The protocol is developed using several model protein systems including: ribonuclease (Rnase) A, myoglobin, bovine carbonic anhydrase (BCA) II, hemoglobin (Hb), and the hemoglobin-haptoglobin (Hb-Hp) protein complex. Folding free energies consistent with those previously determined by other more conventional techniques were obtained for the two-state folding proteins, Rnase A and myoglobin. The protocol successfully detected a previously observed partially unfolded intermediate stabilized in the BCA II folding/unfolding reaction, and it could be used to generate a K(d) value of 0.24 nM for the Hb-Hp complex. The compatibility of the protocol with conventional mass spectrometry-based proteomic sample preparation and analysis methods was also demonstrated in an experiment in which the protocol was used to detect the binding of zinc to superoxide dismutase in the yeast cell lysate sample. The yeast cell sample analyses also helped define the scope of the technique, which requires the presence of globally protected histidine residues in a protein's three-dimensional structure for successful application. © 2011 American Chemical Society

  1. Digital radiography with computerized conventional monitors compared to medical monitors in vertical root fracture diagnosis.

    PubMed

    Tofangchiha, Maryam; Adel, Mamak; Bakhshi, Mahin; Esfehani, Mahsa; Nazeman, Pantea; Ghorbani Elizeyi, Mojgan; Javadi, Amir

    2013-01-01

    Vertical root fracture (VRF) is a complication which is chiefly diagnosed radiographically. Recently, film-based radiography has been substituted with digital radiography. At the moment, there is a wide range of monitors available in the market for viewing digital images. The present study aims to compare the diagnostic accuracy, sensitivity and specificity of medical and conventional monitors in detection of vertical root fractures. In this in vitro study 228 extracted single-rooted human teeth were endodontically treated. Vertical root fractures were induced in 114 samples. The teeth were imaged by a digital charge-coupled device radiography using parallel technique. The images were evaluated by a radiologist and an endodontist on two medical and conventional liquid-crystal display (LCD) monitors twice. Z-test was used to analyze the sensitivity, accuracy and specificity of each monitor. Significance level was set at 0.05. Inter and intra observer agreements were calculated by Cohen's kappa. Accuracy, specificity and sensitivity for conventional monitor were calculated as 67.5%, 72%, 62.5% respectively; and data for medical grade monitor were 67.5%, 66.5% and 68% respectively. Statistical analysis showed no significant differences in detecting VRF between the two techniques. Inter-observer agreement for conventional and medical monitor was 0.47 and 0.55 respectively (moderate). Intra-observer agreement was 0.78 for medical monitor and 0.87 for conventional one (substantial). The type of monitor does not influence diagnosis of vertical root fractures.

  2. Support vector regression to predict porosity and permeability: Effect of sample size

    NASA Astrophysics Data System (ADS)

    Al-Anazi, A. F.; Gates, I. D.

    2012-02-01

    Porosity and permeability are key petrophysical parameters obtained from laboratory core analysis. Cores, obtained from drilled wells, are often few in number for most oil and gas fields. Porosity and permeability correlations based on conventional techniques such as linear regression or neural networks trained with core and geophysical logs suffer poor generalization to wells with only geophysical logs. The generalization problem of correlation models often becomes pronounced when the training sample size is small. This is attributed to the underlying assumption that conventional techniques employing the empirical risk minimization (ERM) inductive principle converge asymptotically to the true risk values as the number of samples increases. In small sample size estimation problems, the available training samples must span the complexity of the parameter space so that the model is able both to match the available training samples reasonably well and to generalize to new data. This is achieved using the structural risk minimization (SRM) inductive principle by matching the capability of the model to the available training data. One method that uses SRM is support vector regression (SVR) network. In this research, the capability of SVR to predict porosity and permeability in a heterogeneous sandstone reservoir under the effect of small sample size is evaluated. Particularly, the impact of Vapnik's ɛ-insensitivity loss function and least-modulus loss function on generalization performance was empirically investigated. The results are compared to the multilayer perception (MLP) neural network, a widely used regression method, which operates under the ERM principle. The mean square error and correlation coefficients were used to measure the quality of predictions. The results demonstrate that SVR yields consistently better predictions of the porosity and permeability with small sample size than the MLP method. Also, the performance of SVR depends on both kernel function type and loss functions used.

  3. COMPARISON OF A GENUS-SPECIFIC CONVENTIONAL PCR AND A SPECIES-SPECIFIC NESTED-PCR FOR MALARIA DIAGNOSIS USING FTA COLLECTED SAMPLES FROM KINGDOM OF SAUDI ARABIA.

    PubMed

    Al-Harthi, Saeed A

    2015-12-01

    Molecular tools are increasingly accepted as the most sensitive and reliable techniques for malaria diagnosis and epidemiological surveys. Also, collection of finger prick blood spots onto filter papers is the most simple and affordable method for samples preservation and posterior molecular analysis, especially in rural endemic regions where malaria remains a major health problem. Two malaria molecular diagnostic tests, a Plasmodium genus-specific conventional PCR and a Plasmodium species-specific Nested PCR, were evaluated using DNA templates prepared from Whatman-FTA cards' dry blood spots using both, Methanol-fixation/Heat-extraction and FTA commercial purification kit. A total of 121 blood samples were collected from six Saudi south-western endemic districts both, as thick and thin films for routine microscopic screening and onto FTA cards for molecular studies. Out of the 121 samples, 75 were P. falciparum positive by at least one technique. No other species of Plasmodium were detected. P. falciparum parasites were identified in 69/75 (92%) samples by microscopic screening in health care centers. P. genus-specific PCR was able to amplify P. falciparum DNA in 41/75 (55%) and 59/75 (79%) samples using Methanol-fixation/Heat-extraction and FTA purification kit, respectively. P. species-specific Nested PCR revealed 68/75 (91%) and 75/75 (100%) positive samples using DNA templates were isolated by Methanol-fixation/Heat- extraction and FTA purification methods, respectively. The species-specific Nested PCR applied to Whatman-FTA preserved and processed blood samples represents the best alternative to classical microscopy for malaria diagnosis, particularly in epidemiological screening.

  4. Analyser-based mammography using single-image reconstruction.

    PubMed

    Briedis, Dahliyani; Siu, Karen K W; Paganin, David M; Pavlov, Konstantin M; Lewis, Rob A

    2005-08-07

    We implement an algorithm that is able to decode a single analyser-based x-ray phase-contrast image of a sample, converting it into an equivalent conventional absorption-contrast radiograph. The algorithm assumes the projection approximation for x-ray propagation in a single-material object embedded in a substrate of approximately uniform thickness. Unlike the phase-contrast images, which have both directional bias and a bias towards edges present in the sample, the reconstructed images are directly interpretable in terms of the projected absorption coefficient of the sample. The technique was applied to a Leeds TOR[MAM] phantom, which is designed to test mammogram quality by the inclusion of simulated microcalcifications, filaments and circular discs. This phantom was imaged at varying doses using three modalities: analyser-based synchrotron phase-contrast images converted to equivalent absorption radiographs using our algorithm, slot-scanned synchrotron imaging and imaging using a conventional mammography unit. Features in the resulting images were then assigned a quality score by volunteers. The single-image reconstruction method achieved higher scores at equivalent and lower doses than the conventional mammography images, but no improvement of visualization of the simulated microcalcifications, and some degradation in image quality at reduced doses for filament features.

  5. Approaches to Recruiting 'Hard-To-Reach' Populations into Re-search: A Review of the Literature.

    PubMed

    Shaghaghi, Abdolreza; Bhopal, Raj S; Sheikh, Aziz

    2011-01-01

    'Hard-to-reach' is a term used to describe those sub-groups of the population that may be difficult to reach or involve in research or public health programmes. Application of a single term to call these sub-sections of populations implies a homogeneity within distinct groups, which does not necessarily exist. Different sampling techniques were introduced so far to recruit hard-to-reach populations. In this article, we have reviewed a range of ap-proaches that have been used to widen participation in studies. We performed a Pubmed and Google search for relevant English language articles using the keywords and phrases: (hard-to-reach AND population* OR sampl*), (hidden AND population* OR sample*) and ("hard to reach" AND population* OR sample*) and a consul-tation of the retrieved articles' bibliographies to extract empirical evidence from publications that discussed or examined the use of sampling techniques to recruit hidden or hard-to-reach populations in health studies. Reviewing the literature has identified a range of techniques to recruit hard-to-reach populations, including snowball sampling, respondent-driven sampling (RDS), indigenous field worker sampling (IFWS), facility-based sampling (FBS), targeted sampling (TS), time-location (space) sampling (TLS), conventional cluster sampling (CCS) and capture re-capture sampling (CR). The degree of compliance with a study by a certain 'hard-to-reach' group de-pends on the characteristics of that group, recruitment technique used and the subject of inter-est. Irrespective of potential advantages or limitations of the recruitment techniques reviewed, their successful use depends mainly upon our knowledge about specific characteristics of the target populations. Thus in line with attempts to expand the current boundaries of our know-ledge about recruitment techniques in health studies and their applications in varying situa-tions, we should also focus on possibly all contributing factors which may have an impact on participation rate within a defined population group.

  6. Evaluation of marginal gap of Ni-Cr copings made with conventional and accelerated casting techniques.

    PubMed

    Tannamala, Pavan Kumar; Azhagarasan, Nagarasampatti Sivaprakasam; Shankar, K Chitra

    2013-01-01

    Conventional casting techniques following the manufacturers' recommendations are time consuming. Accelerated casting techniques have been reported, but their accuracy with base metal alloys has not been adequately studied. We measured the vertical marginal gap of nickel-chromium copings made by conventional and accelerated casting techniques and determined the clinical acceptability of the cast copings in this study. Experimental design, in vitro study, lab settings. Ten copings each were cast by conventional and accelerated casting techniques. All copings were identical, only their mold preparation schedules differed. Microscopic measurements were recorded at ×80 magnification on the perpendicular to the axial wall at four predetermined sites. The marginal gap values were evaluated by paired t test. The mean marginal gap by conventional technique (34.02 μm) is approximately 10 μm lesser than that of accelerated casting technique (44.62 μm). As the P value is less than 0.0001, there is highly significant difference between the two techniques with regard to vertical marginal gap. The accelerated casting technique is time saving and the marginal gap measured was within the clinically acceptable limits and could be an alternative to time-consuming conventional techniques.

  7. Acquired Codes of Meaning in Data Visualization and Infographics: Beyond Perceptual Primitives.

    PubMed

    Byrne, Lydia; Angus, Daniel; Wiles, Janet

    2016-01-01

    While information visualization frameworks and heuristics have traditionally been reluctant to include acquired codes of meaning, designers are making use of them in a wide variety of ways. Acquired codes leverage a user's experience to understand the meaning of a visualization. They range from figurative visualizations which rely on the reader's recognition of shapes, to conventional arrangements of graphic elements which represent particular subjects. In this study, we used content analysis to codify acquired meaning in visualization. We applied the content analysis to a set of infographics and data visualizations which are exemplars of innovative and effective design. 88% of the infographics and 71% of data visualizations in the sample contain at least one use of figurative visualization. Conventions on the arrangement of graphics are also widespread in the sample. In particular, a comparison of representations of time and other quantitative data showed that conventions can be specific to a subject. These results suggest that there is a need for information visualization research to expand its scope beyond perceptual channels, to include social and culturally constructed meaning. Our paper demonstrates a viable method for identifying figurative techniques and graphic conventions and integrating them into heuristics for visualization design.

  8. Comparative Analysis Between Computed and Conventional Inferior Alveolar Nerve Block Techniques.

    PubMed

    Araújo, Gabriela Madeira; Barbalho, Jimmy Charles Melo; Dias, Tasiana Guedes de Souza; Santos, Thiago de Santana; Vasconcellos, Ricardo José de Holanda; de Morais, Hécio Henrique Araújo

    2015-11-01

    The aim of this randomized, double-blind, controlled trial was to compare the computed and conventional inferior alveolar nerve block techniques in symmetrically positioned inferior third molars. Both computed and conventional anesthetic techniques were performed in 29 healthy patients (58 surgeries) aged between 18 and 40 years. The anesthetic of choice was 2% lidocaine with 1: 200,000 epinephrine. The Visual Analogue Scale assessed the pain variable after anesthetic infiltration. Patient satisfaction was evaluated using the Likert Scale. Heart and respiratory rates, mean time to perform technique, and the need for additional anesthesia were also evaluated. Pain variable means were higher for the conventional technique as compared with computed, 3.45 ± 2.73 and 2.86 ± 1.96, respectively, but no statistically significant differences were found (P > 0.05). Patient satisfaction showed no statistically significant differences. The average computed technique runtime and the conventional were 3.85 and 1.61 minutes, respectively, showing statistically significant differences (P <0.001). The computed anesthetic technique showed lower mean pain perception, but did not show statistically significant differences when contrasted to the conventional technique.

  9. Determination of Se in soil samples using the proton induced X-ray emission technique

    NASA Astrophysics Data System (ADS)

    Cruvinel, Paulo E.; Flocchini, Robert G.

    1993-04-01

    An alternative method for the direct determination of total Se in soil samples is presented. A large number of trace elements is present in soil at concentration values in the range of part per billion and tenths of parts of million. The most common are the trace elements of Al, Si, K, Ca, Ti, V, Cr, Fe, Cu, Zn, Br, Rb, Mo, Cd and Pb. As for biological samples many of these elements are of great importance for the nutrition of plants, while others are toxic and others have an unknown role. Selenium is an essential micronutrient for humans and animals but it is also known that in certain areas Se deficiency or toxicity has caused endemic disease to livestock and humans through the soil-plant-animal linkage. In this work the suitability of the proton induced X-ray emission (PIXE) technique as a fast and nondestructive technique useful to measure total the Se content in soil samples is demonstrated. To validate the results a comparison of data collected using the conventional atomic absorption spectrophotometry (AAS) method was performed.

  10. Near-field cathodoluminescence studies on n-doped gallium nitride films

    NASA Astrophysics Data System (ADS)

    Nogales, E.; Joachimsthaler, I.; Heiderhoff, R.; Piqueras, J.; Balk, L. J.

    2002-07-01

    Near-field cathodoluminescence (NFCL) has been used to characterize hydride vapor phase epitaxy grown n-GaN films. This technique can obtain high resolution luminescence images and perform local measurements of the diffusion length for minority carriers in different parts of the sample. NFCL contrast observed in round growth hillocks at the sample surface, with a diameter of less than 10 mum, is compared with that observed by conventional cathodoluminescence in scanning electron microscope (CLSEM) techniques. In particular NFCL images reveal features not detected by CLSEM which is explained by the fact that under near field conditions the signal arises from a depth of only several tens of nanometers and is then directly related to the surface hillocks. Diffusion lengths of about 0.4 and 4 mum have been found for the holes in different regions of the samples at room temperature. The order of magnitude of these minority carriers diffusion lengths is in good agreement with previous measurements performed at different GaN samples with other techniques. The NFCL contrast and the differences in the measured diffusion lengths are discussed and explained by variations in local trap concentrations.

  11. Detection of Hepatic Fibrosis in Ex Vivo Liver Samples Using an Open-Photoacoustic-Cell Method: Feasibility Study

    NASA Astrophysics Data System (ADS)

    Stolik, S.; Fabila, D. A.; de la Rosa, J. M.; Escobedo, G.; Suárez-Álvarez, K.; Tomás, S. A.

    2015-09-01

    Design of non-invasive and accurate novel methods for liver fibrosis diagnosis has gained growing interest. Different stages of liver fibrosis were induced in Wistar rats by intraperitoneally administering different doses of carbon tetrachloride. The liver fibrosis degree was conventionally determined by means of histological examination. An open-photoacoustic-cell (OPC) technique for the assessment of liver fibrosis was developed and is reported here. The OPC technique is based on the fact that the thermal diffusivity can be accurately measured by photoacoustics taking into consideration the photoacoustic signal amplitude versus the modulation frequency. This technique measures directly the heat generated in a sample, due to non-radiative de-excitation processes, following the absorption of light. The thermal diffusivity was measured with a home-made open-photoacoustic-cell system that was specially designed to perform the measurement from ex vivo liver samples. The human liver tissue showed a significant increase in the thermal diffusivity depending on the fibrosis stage. Specifically, liver samples from rats exhibiting hepatic fibrosis showed a significantly higher value of the thermal diffusivity than for control animals.

  12. Effectiveness of Mind Mapping in English Teaching among VIII Standard Students

    ERIC Educational Resources Information Center

    Hallen, D.; Sangeetha, N.

    2015-01-01

    The aim of the study is to find out the effectiveness of mind mapping technique over conventional method in teaching English at high school level (VIII), in terms of Control and Experimental group. The sample of the study comprised, 60 VIII Standard students in Tiruchendur Taluk. Mind Maps and Achievement Test (Pretest & Posttest) were…

  13. Vocabulary Teaching in Foreign Language via Audiovisual Method Technique of Listening and Following Writing Scripts

    ERIC Educational Resources Information Center

    Bozavli, Ebubekir

    2017-01-01

    The objective is hereby study is to compare the effects of conventional and audiovisual methods on learning efficiency and success of retention with regard to vocabulary teaching in foreign language. Research sample consists of 21 undergraduate and 7 graduate students studying at Department of French Language Teaching, Kazim Karabekir Faculty of…

  14. Diagnosis of ectoparasitism.

    PubMed

    Klayman, E; Schillhorn van Veen, T W

    1981-10-01

    A vacuum cleaner fitted with an in-line filter was used to collect samples from suspected cases of ectoparasitic infestation in animals. Filter samples, including hair, were hydrolyzed in hot potassium hydroxide, and the residue was concentrated by flotation in concentrated sugar and then examined under a microscope. The 206 animals examined yielded fleas, flea feces, forage mites, Cheyletiella, Sarcoptes, Chorioptes, Psoroptes, Otodectes, Demodex and Damalinia spp. The sensitivity of this technique in the diagnosis of ectoparasites was better than that of conventional skin scrapings or direct observation.

  15. Pork detection in binary meat mixtures and some commercial food products using conventional and real-time PCR techniques.

    PubMed

    Al-Kahtani, Hassan A; Ismail, Elsayed A; Asif Ahmed, Mohammed

    2017-03-15

    Pork DNA was detected in meat mixtures using both conventional PCR and real-time PCR (RT-PCR). Thirty meat mixtures containing beef, chicken, camel, rabbit, goat and sheep with varying percentage of pork (0%, 1%, 5%, 10%, and 20%) and 75 commercial food products, were analyzed using conventional and RT-PCR to determine the presence of pork DNA. Pork DNA standard curves and cycle threshold (Ct) values were used for quantification. The detection limits for pork DNA in the mixtures were 0.22, 0.047, 0.048, 0.0000037, 0.015ng/μl respectively. Unlike conventional PCR, RT-PCR detected pork DNA in nine processed food samples [chicken sausages (2), chicken luncheon (2), turkey meat loaf, milk chocolate with soft nougat, jelly, cake, and candies] at pork DNA concentrations of 0.0001ng/μl or less. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Analytical performance of a low-gas-flow torch optimized for inductively coupled plasma atomic emission spectrometry

    USGS Publications Warehouse

    Montaser, A.; Huse, G.R.; Wax, R.A.; Chan, S.-K.; Golightly, D.W.; Kane, J.S.; Dorrzapf, A.F.

    1984-01-01

    An inductively coupled Ar plasma (ICP), generated in a lowflow torch, was investigated by the simplex optimization technique for simultaneous, multielement, atomic emission spectrometry (AES). The variables studied included forward power, observation height, gas flow (outer, intermediate, and nebulizer carrier) and sample uptake rate. When the ICP was operated at 720-W forward power with a total gas flow of 5 L/min, the signal-to-background ratios (S/B) of spectral lines from 20 elements were either comparable or inferior, by a factor ranging from 1.5 to 2, to the results obtained from a conventional Ar ICP. Matrix effect studies on the Ca-PO4 system revealed that the plasma generated in the low-flow torch was as free of vaporizatton-atomizatton interferences as the conventional ICP, but easily ionizable elements produced a greater level of suppression or enhancement effects which could be reduced at higher forward powers. Electron number densities, as determined via the series until line merging technique, were tower ht the plasma sustained in the low-flow torch as compared with the conventional ICP. ?? 1984 American Chemical Society.

  17. Comparison of conventional culture method and fluorescent in situ hybridization technique for detection of Listeria spp. in ground beef, turkey, and chicken breast fillets in İzmir, Turkey.

    PubMed

    Baysal, Ayse Handan

    2014-12-01

    The occurrence of Listeria species in refrigerated fresh chicken breast fillet, turkey breast fillet, and ground beef was evaluated, comparing the conventional culture method and fluorescent in situ hybridization (FISH). FISH uses hybridization of a nucleic acid sequence target of a microorganism with a specific DNA probe labeled with a fluorochrome and imaging by a fluorescence microscope. First, Listeria was inoculated in chicken breast fillet, turkey breast fillet, or ground beef, and the applicability of the FISH method was evaluated. Second, Listeria was detected in fresh chicken breast fillet, turkey breast fillet, and ground beef by culture and FISH methods. Listeria was isolated from 27 (37.4%) of 216 samples by the standard culture method, whereas FISH detected 25 (24.7%) preenriched samples. Of these isolates, 17 (63%) were L. innocua, 6 (22%) L. welshimeri, and 4 (14.8%) L. seeligeri. Overall, the prevalences of Listeria spp. found with the conventional culture method in chicken breast fillet, turkey breast fillet, and ground beef were 9.7, 6.9, and 20.8%, whereas with the FISH technique these values were 11.1, 6.9, and 16.7%, respectively. The molecular FISH technique appears to be a cheap, sensitive, and time-efficient procedure that could be used for routine detection of Listeria spp. in meat. This study showed that retail raw meats are potentially contaminated with Listeria spp. and are, thus, vehicles for transmitting diseases caused by foodborne pathogens, underlining the need for increased precautions, such as implementation of hazard analysis and critical control points and consumer food safety education.

  18. Soft bilateral filtering volumetric shadows using cube shadow maps

    PubMed Central

    Ali, Hatam H.; Sunar, Mohd Shahrizal; Kolivand, Hoshang

    2017-01-01

    Volumetric shadows often increase the realism of rendered scenes in computer graphics. Typical volumetric shadows techniques do not provide a smooth transition effect in real-time with conservation on crispness of boundaries. This research presents a new technique for generating high quality volumetric shadows by sampling and interpolation. Contrary to conventional ray marching method, which requires extensive time, this proposed technique adopts downsampling in calculating ray marching. Furthermore, light scattering is computed in High Dynamic Range buffer to generate tone mapping. The bilateral interpolation is used along a view rays to smooth transition of volumetric shadows with respect to preserving-edges. In addition, this technique applied a cube shadow map to create multiple shadows. The contribution of this technique isreducing the number of sample points in evaluating light scattering and then introducing bilateral interpolation to improve volumetric shadows. This contribution is done by removing the inherent deficiencies significantly in shadow maps. This technique allows obtaining soft marvelous volumetric shadows, having a good performance and high quality, which show its potential for interactive applications. PMID:28632740

  19. In situ detrital zircon (U-Th)/He thermochronology

    NASA Astrophysics Data System (ADS)

    Tripathy, A.; Monteleone, B. D.; van Soest, M. C.; Hodges, K.; Hourigan, J. K.

    2010-12-01

    Detrital studies of both sand and rock are relevant to many problems, ranging from the climate and tectonics feedback debate to the long-term record of orogenic evolution. When applying the conventional (U-Th)/He technique to such studies, two important issues arise. Often, only euhedral grains are permissible for analysis in order to make simple geometric corrections for α-recoil. In detrital samples, this is problematic because euhedral grains can be scarce due to mechanical abrasion during transport, and potentially introduce bias in favour of more proximally sourced grains. Second, inherent to detrital studies is the need to date many grains (>100) per sample to ensure a representative sampling of the sediment source region, thus making robust conventional detrital studies both expensive and time-consuming. UV laser microprobes can improve this by permitting careful targeting of the grain interior away from the α-ejection zone, rendering the α-recoil correction unnecessary, thus eliminating bias toward euhedral grains. In the Noble Gas, Geochemistry, and Geochronology Laboratory at ASU, apatite and zircon have been successfully dated using in situ methods. For this study, the conventional and in situ techniques are compared by dating zircons from a modern river sand that drains a small catchment in the Mesozoic-Cenozoic Ladakh Batholith in NW India. This sample has a simple provenance, which allows us to demonstrate the robustness of the in situ method. Moreover, different microbeam techniques will be explored to establish the most efficient approach to obtain accurate and precise U-Th concentrations using synrock, which is our powdered, homogenized, and reconstituted zircon-rock standard. Without this, such in situ U-Th data would be difficult to obtain. 117 zircons were dated using the conventional (U-Th)/He method, revealing dates ranging from 9.70±0.35 to 106.6±3.5 Ma (2σ) with the major mode at 26 Ma. For comparison, 44 grains were dated using the in situ method, utilizing SIMS to determine the U-Th concentrations. The major mode is the same as the conventional dataset, with only single outliers missing from the in situ dataset. The in situ method is described as follows: Zircons are polished and imaged using cathodoluminesence to guide laser spot placement. Then, each grain is ablated with a 193nm ArF Excimer laser using 20-35µm beam sizes and depths of 10-17µm. After purification, 4He is analyzed on a ThermoScientific Helix Split Flight Tube mass spectrometer. U-Th concentrations are measured on the polished mount using a Cameca IMS 6f by placing a 60µm diameter beam directly over the He laser pit to cover the surface area contributing to the measured He. In theory, using LA-ICP-MS to obtain U-Th concentrations could be a faster, cheaper, but possibly less precise, technique. However, using laser ablation would allow pit sizes that average the U-Th concentration over the volume of material available that contributes to the measured He, thus accounting for intracrystalline α-recoil effects. Preliminary data on slabs of Sri Lankan zircon suggest this could be a viable method, but will require further exploration and refinement.

  20. High speed wavefront sensorless aberration correction in digital micromirror based confocal microscopy.

    PubMed

    Pozzi, P; Wilding, D; Soloviev, O; Verstraete, H; Bliek, L; Vdovin, G; Verhaegen, M

    2017-01-23

    The quality of fluorescence microscopy images is often impaired by the presence of sample induced optical aberrations. Adaptive optical elements such as deformable mirrors or spatial light modulators can be used to correct aberrations. However, previously reported techniques either require special sample preparation, or time consuming optimization procedures for the correction of static aberrations. This paper reports a technique for optical sectioning fluorescence microscopy capable of correcting dynamic aberrations in any fluorescent sample during the acquisition. This is achieved by implementing adaptive optics in a non conventional confocal microscopy setup, with multiple programmable confocal apertures, in which out of focus light can be separately detected, and used to optimize the correction performance with a sampling frequency an order of magnitude faster than the imaging rate of the system. The paper reports results comparing the correction performances to traditional image optimization algorithms, and demonstrates how the system can compensate for dynamic changes in the aberrations, such as those introduced during a focal stack acquisition though a thick sample.

  1. Potential of cancer screening with serum surface-enhanced Raman spectroscopy and a support vector machine

    NASA Astrophysics Data System (ADS)

    Li, S. X.; Zhang, Y. J.; Zeng, Q. Y.; Li, L. F.; Guo, Z. Y.; Liu, Z. M.; Xiong, H. L.; Liu, S. H.

    2014-06-01

    Cancer is the most common disease to threaten human health. The ability to screen individuals with malignant tumours with only a blood sample would be greatly advantageous to early diagnosis and intervention. This study explores the possibility of discriminating between cancer patients and normal subjects with serum surface-enhanced Raman spectroscopy (SERS) and a support vector machine (SVM) through a peripheral blood sample. A total of 130 blood samples were obtained from patients with liver cancer, colonic cancer, esophageal cancer, nasopharyngeal cancer, gastric cancer, as well as 113 blood samples from normal volunteers. Several diagnostic models were built with the serum SERS spectra using SVM and principal component analysis (PCA) techniques. The results show that a diagnostic accuracy of 85.5% is acquired with a PCA algorithm, while a diagnostic accuracy of 95.8% is obtained using radial basis function (RBF), PCA-SVM methods. The results prove that a RBF kernel PCA-SVM technique is superior to PCA and conventional SVM (C-SVM) algorithms in classification serum SERS spectra. The study demonstrates that serum SERS, in combination with SVM techniques, has great potential for screening cancerous patients with any solid malignant tumour through a peripheral blood sample.

  2. High quality tissue miniarray technique using a conventional TV/radio telescopic antenna.

    PubMed

    Elkablawy, Mohamed A; Albasri, Abdulkader M

    2015-01-01

    The tissue microarray (TMA) is widely accepted as a fast and cost-effective research tool for in situ tissue analysis in modern pathology. However, the current automated and manual TMA techniques have some drawbacks restricting their productivity. Our study aimed to introduce an improved manual tissue miniarray (TmA) technique that is simple and readily applicable to a broad range of tissue samples. In this study, a conventional TV/radio telescopic antenna was used to punch tissue cores manually from donor paraffin embedded tissue blocks which were pre-incubated at 40oC. The cores were manually transferred, organized and attached to a standard block mould, and filled with liquid paraffin to construct TmA blocks without any use of recipient paraffin blocks. By using a conventional TV/radio antenna, it was possible to construct TmA paraffin blocks with variable formats of array size and number (2-mm x 42, 2.5-mm x 30, 3-mm x 24, 4-mm x 20 and 5-mm x 12 cores). Up to 2-mm x 84 cores could be mounted and stained on a standard microscopic slide by cutting two sections from two different blocks and mounting them beside each other. The technique was simple and caused minimal damage to the donor blocks. H and E and immunostained slides showed well-defined tissue morphology and array configuration. This technique is easy to reproduce, quick, inexpensive and creates uniform blocks with abundant tissues without specialized equipment. It was found to improve the stability of the cores within the paraffin block and facilitated no losses during cutting and immunostaining.

  3. Method for charging a hydrogen getter

    DOEpatents

    Tracy, C.E.; Keyser, M.A.; Benson, D.K.

    1998-09-15

    A method for charging a sample of either a permanent or reversible getter material with a high concentration of hydrogen while maintaining a base pressure below 10{sup {minus}4} torr at room temperature involves placing the sample of hydrogen getter material in a chamber, activating the sample of hydrogen getter material, overcharging the sample of getter material through conventional charging techniques to a high concentration of hydrogen, and then subjecting the sample of getter material to a low temperature vacuum bake-out process. Application of the method results in a reversible hydrogen getter which is highly charged to maximum capacities of hydrogen and which concurrently exhibits minimum hydrogen vapor pressures at room temperatures. 9 figs.

  4. Satellite-aided survey sampling and implementation in low- and middle-income contexts: a low-cost/low-tech alternative.

    PubMed

    Haenssgen, Marco J

    2015-01-01

    The increasing availability of online maps, satellite imagery, and digital technology can ease common constraints of survey sampling in low- and middle-income countries. However, existing approaches require specialised software and user skills, professional GPS equipment, and/or commercial data sources; they tend to neglect spatial sampling considerations when using satellite maps; and they continue to face implementation challenges analogous to conventional survey implementation methods. This paper presents an alternative way of utilising satellite maps and digital aides that aims to address these challenges. The case studies of two rural household surveys in Rajasthan (India) and Gansu (China) compare conventional survey sampling and implementation techniques with the use of online map services such as Google, Bing, and HERE maps. Modern yet basic digital technology can be integrated into the processes of preparing, implementing, and monitoring a rural household survey. Satellite-aided systematic random sampling enhanced the spatial representativeness of the village samples and entailed savings of approximately £4000 compared to conventional household listing, while reducing the duration of the main survey by at least 25 %. This low-cost/low-tech satellite-aided survey sampling approach can be useful for student researchers and resource-constrained research projects operating in low- and middle-income contexts with high survey implementation costs. While achieving transparent and efficient survey implementation at low costs, researchers aiming to adopt a similar process should be aware of the locational, technical, and logistical requirements as well as the methodological challenges of this strategy.

  5. Simulations of multi-contrast x-ray imaging using near-field speckles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zdora, Marie-Christine; Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, OX11 0DE, United Kingdom and Department of Physics & Astronomy, University College London, London, WC1E 6BT; Thibault, Pierre

    2016-01-28

    X-ray dark-field and phase-contrast imaging using near-field speckles is a novel technique that overcomes limitations inherent in conventional absorption x-ray imaging, i.e. poor contrast for features with similar density. Speckle-based imaging yields a wealth of information with a simple setup tolerant to polychromatic and divergent beams, and simple data acquisition and analysis procedures. Here, we present a simulation software used to model the image formation with the speckle-based technique, and we compare simulated results on a phantom sample with experimental synchrotron data. Thorough simulation of a speckle-based imaging experiment will help for better understanding and optimising the technique itself.

  6. Diffraction enhance x-ray imaging for quantitative phase contrast studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agrawal, A. K.; Singh, B., E-mail: balwants@rrcat.gov.in; Kashyap, Y. S.

    2016-05-23

    Conventional X-ray imaging based on absorption contrast permits limited visibility of feature having small density and thickness variations. For imaging of weakly absorbing material or materials possessing similar densities, a novel phase contrast imaging techniques called diffraction enhanced imaging has been designed and developed at imaging beamline Indus-2 RRCAT Indore. The technique provides improved visibility of the interfaces and show high contrast in the image forsmall density or thickness gradients in the bulk. This paper presents basic principle, instrumentation and analysis methods for this technique. Initial results of quantitative phase retrieval carried out on various samples have also been presented.

  7. Biomechanical comparison of the double-push technique and the conventional skate skiing technique in cross-country sprint skiing.

    PubMed

    Stöggl, Thomas; Müller, Erich; Lindinger, Stefan

    2008-09-01

    The aims of the study were to: (1) adapt the "double-push" technique from inline skating to cross-country skiing; (2) compare this new skiing technique with the conventional skate skiing cross-country technique; and (3) test the hypothesis that the double-push technique improves skiing speed in a short sprint. 13 elite skiers performed maximum-speed sprints over 100 m using the double-push skate skiing technique and using the conventional "V2" skate skiing technique. Pole and plantar forces, knee angle, cycle characteristics, and electromyography of nine lower body muscles were analysed. We found that the double-push technique could be successfully transferred to cross-country skiing, and that this new technique is faster than the conventional skate skiing technique. The double-push technique was 2.9 +/- 2.2% faster (P < 0.001), which corresponds to a time advantage of 0.41 +/- 0.31 s over 100 m. The double-push technique had a longer cycle length and a lower cycle rate, and it was characterized by higher muscle activity, higher knee extension amplitudes and velocities, and higher peak foot forces, especially in the first phase of the push-off. Also, the foot was more loaded laterally in the double-push technique than in the conventional skate skiing technique.

  8. Speckle-field digital holographic microscopy.

    PubMed

    Park, YongKeun; Choi, Wonshik; Yaqoob, Zahid; Dasari, Ramachandra; Badizadegan, Kamran; Feld, Michael S

    2009-07-20

    The use of coherent light in conventional holographic phase microscopy (HPM) poses three major drawbacks: poor spatial resolution, weak depth sectioning, and fixed pattern noise due to unwanted diffraction. Here, we report a technique which can overcome these drawbacks, but maintains the advantage of phase microscopy - high contrast live cell imaging and 3D imaging. A speckle beam of a complex spatial pattern is used for illumination to reduce fixed pattern noise and to improve optical sectioning capability. By recording of the electric field of speckle, we demonstrate high contrast 3D live cell imaging without the need for axial scanning - neither objective lens nor sample stage. This technique has great potential in studying biological samples with improved sensitivity, resolution and optical sectioning capability.

  9. Effect of sputtering power on MgF2 thin films deposited by sputtering technique under fluorine trapping

    NASA Astrophysics Data System (ADS)

    De, Rajnarayan; Haque, S. Maidul; Tripathi, S.; Prathap, C.; Rao, K. Divakar; Sahoo, N. K.

    2016-05-01

    A non-conventional magnetron sputtering technique was explored to deposit magnesium fluoride thin films using the concept of fluorine gas trapping without the introduction of additional fluorine gas flow inside the chamber. The effect of magnetron power from 50 W to 250 W has been explored on structural, optical and physical properties of the samples. Polycrystalline nature with tetragonal crystallinity of the films has been confirmed by GIXRD measurements along with thickness dependency. Monotonic increase of attenuation coefficient (k) with RF power has been explained in terms of target compound dissociation probability. In conclusion, with fluorine trapping method, the samples deposited at lower RF powers (<100 W) are found to be more suitable for optical applications.

  10. Evaluation of new indigenous "point-of-care" ABO and Rh grouping device.

    PubMed

    Tiwari, Aseem Kumar; Setya, Divya; Aggarwal, Geet; Arora, Dinesh; Dara, Ravi C; Ratan, Ankita; Bhardwaj, Gunjan; Acharya, Devi Prasad

    2018-01-01

    Erycard 2.0 is a "point-of-care" device that is primarily being used for patient blood grouping before transfusion. Erycard 2.0 was compared with conventional slide technology for accuracy and time taken for ABO and Rh forward grouping result with column agglutination technology (CAT) being the gold standard. Erycard 2.0 as a device was also evaluated for its stability under different storage conditions and stability of result till 48 h. In addition, grouping of hemolyzed samples was also tested with Erycard 2.0. Ease of use of Erycard 2.0 was evaluated with a survey among paramedical staff. Erycard 2.0 demonstrated 100% concordance with CAT as compared with slide technique (98.9%). Mean time taken per test by Erycard 2.0 and slide technique was 5.13 min and 1.7 min, respectively. After pretesting storage under different temperature and humidity conditions, Erycard 2.0 did not show any deviation from the result. The result did not change even after 48 h of testing and storage under room temperature. 100% concordance was recorded between pre- and post-hemolyzed blood grouping. Ease of use survey revealed that Erycard 2.0 was more acceptable to paramedical staff for its simplicity, objectivity, and performance than conventional slide technique. Erycard 2.0 can be used as "point-of-care" device for blood donor screening for ABO and Rh blood group and can possibly replace conventional slide technique.

  11. Evaluation of new indigenous “point-of-care” ABO and Rh grouping device

    PubMed Central

    Tiwari, Aseem Kumar; Setya, Divya; Aggarwal, Geet; Arora, Dinesh; Dara, Ravi C.; Ratan, Ankita; Bhardwaj, Gunjan; Acharya, Devi Prasad

    2018-01-01

    BACKGROUND: Erycard 2.0 is a “point-of-care” device that is primarily being used for patient blood grouping before transfusion. MATERIALS AND METHODS: Erycard 2.0 was compared with conventional slide technology for accuracy and time taken for ABO and Rh forward grouping result with column agglutination technology (CAT) being the gold standard. Erycard 2.0 as a device was also evaluated for its stability under different storage conditions and stability of result till 48 h. In addition, grouping of hemolyzed samples was also tested with Erycard 2.0. Ease of use of Erycard 2.0 was evaluated with a survey among paramedical staff. RESULTS: Erycard 2.0 demonstrated 100% concordance with CAT as compared with slide technique (98.9%). Mean time taken per test by Erycard 2.0 and slide technique was 5.13 min and 1.7 min, respectively. After pretesting storage under different temperature and humidity conditions, Erycard 2.0 did not show any deviation from the result. The result did not change even after 48 h of testing and storage under room temperature. 100% concordance was recorded between pre- and post-hemolyzed blood grouping. Ease of use survey revealed that Erycard 2.0 was more acceptable to paramedical staff for its simplicity, objectivity, and performance than conventional slide technique. CONCLUSION: Erycard 2.0 can be used as “point-of-care” device for blood donor screening for ABO and Rh blood group and can possibly replace conventional slide technique. PMID:29403211

  12. Flood damage assessment using computer-assisted analysis of color infrared photography

    USGS Publications Warehouse

    Anderson, William H.

    1978-01-01

    Use of digitized aerial photographs for flood damage assessment in agriculture is new and largely untested. However, under flooding circumstances similar to the 1975 Red River Valley flood, computer-assisted techniques can be extremely useful, especially if detailed crop damage estimates are needed within a relatively short period of time.Airphoto interpretation techniques, manual or computer-assisted, are not intended to replace conventional ground survey and sampling procedures. But their use should be considered a valuable addition to the tools currently available for assessing agricultural flood damage.

  13. Quantum-optical coherence tomography with classical light.

    PubMed

    Lavoie, J; Kaltenbaek, R; Resch, K J

    2009-03-02

    Quantum-optical coherence tomography (Q-OCT) is an interferometric technique for axial imaging offering several advantages over conventional methods. Chirped-pulse interferometry (CPI) was recently demonstrated to exhibit all of the benefits of the quantum interferometer upon which Q-OCT is based. Here we use CPI to measure axial interferograms to profile a sample accruing the important benefits of Q-OCT, including automatic dispersion cancellation, but with 10 million times higher signal. Our technique solves the artifact problem in Q-OCT and highlights the power of classical correlation in optical imaging.

  14. Multiclass Bayes error estimation by a feature space sampling technique

    NASA Technical Reports Server (NTRS)

    Mobasseri, B. G.; Mcgillem, C. D.

    1979-01-01

    A general Gaussian M-class N-feature classification problem is defined. An algorithm is developed that requires the class statistics as its only input and computes the minimum probability of error through use of a combined analytical and numerical integration over a sequence simplifying transformations of the feature space. The results are compared with those obtained by conventional techniques applied to a 2-class 4-feature discrimination problem with results previously reported and 4-class 4-feature multispectral scanner Landsat data classified by training and testing of the available data.

  15. A Simplified Technique for Implant-Abutment Level Impression after Soft Tissue Adaptation around Provisional Restoration

    PubMed Central

    Kutkut, Ahmad; Abu-Hammad, Osama; Frazer, Robert

    2016-01-01

    Impression techniques for implant restorations can be implant level or abutment level impressions with open tray or closed tray techniques. Conventional implant-abutment level impression techniques are predictable for maximizing esthetic outcomes. Restoration of the implant traditionally requires the use of the metal or plastic impression copings, analogs, and laboratory components. Simplifying the dental implant restoration by reducing armamentarium through incorporating conventional techniques used daily for crowns and bridges will allow more general dentists to restore implants in their practices. The demonstrated technique is useful when modifications to implant abutments are required to correct the angulation of malpositioned implants. This technique utilizes conventional crown and bridge impression techniques. As an added benefit, it reduces costs by utilizing techniques used daily for crowns and bridges. The aim of this report is to describe a simplified conventional impression technique for custom abutments and modified prefabricated solid abutments for definitive restorations. PMID:29563457

  16. Femtosecond laser etching of dental enamel for bracket bonding.

    PubMed

    Kabas, Ayse Sena; Ersoy, Tansu; Gülsoy, Murat; Akturk, Selcuk

    2013-09-01

    The aim is to investigate femtosecond laser ablation as an alternative method for enamel etching used before bonding orthodontic brackets. A focused laser beam is scanned over enamel within the area of bonding in a saw tooth pattern with a varying number of lines. After patterning, ceramic brackets are bonded and bonding quality of the proposed technique is measured by a universal testing machine. The results are compared to the conventional acid etching method. Results show that bonding strength is a function of laser average power and the density of the ablated lines. Intrapulpal temperature changes are also recorded and observed minimal effects are observed. Enamel surface of the samples is investigated microscopically and no signs of damage or cracking are observed. In conclusion, femtosecond laser exposure on enamel surface yields controllable patterns that provide efficient bonding strength with less removal of dental tissue than conventional acid-etching technique.

  17. Evaluation of analytical performance and reliability of direct nanoLC-nanoESI-high resolution mass spectrometry for profiling the (xeno)metabolome.

    PubMed

    Chetwynd, Andrew J; David, Arthur; Hill, Elizabeth M; Abdul-Sada, Alaa

    2014-10-01

    Mass spectrometry (MS) profiling techniques are used for analysing metabolites and xenobiotics in biofluids; however, detection of low abundance compounds using conventional MS techniques is poor. To counter this, nanoflow ultra-high-pressure liquid chromatography-nanoelectrospray ionization-time-of-flight MS (nUHPLC-nESI-TOFMS), which has been used primarily for proteomics, offers an innovative prospect for profiling small molecules. Compared to conventional UHPLC-ESI-TOFMS, nUHPLC-nESI-TOFMS enhanced detection limits of a variety of (xeno)metabolites by between 2 and 2000-fold. In addition, this study demonstrates for the first time excellent repeatability and reproducibility for analysis of urine and plasma samples using nUHPLC-nESI-TOFMS, supporting implementation of this platform as a novel approach for high-throughput (xeno)metabolomics. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Discrimination of transgenic soybean seeds by terahertz spectroscopy

    NASA Astrophysics Data System (ADS)

    Liu, Wei; Liu, Changhong; Chen, Feng; Yang, Jianbo; Zheng, Lei

    2016-10-01

    Discrimination of genetically modified organisms is increasingly demanded by legislation and consumers worldwide. The feasibility of a non-destructive discrimination of glyphosate-resistant and conventional soybean seeds and their hybrid descendants was examined by terahertz time-domain spectroscopy system combined with chemometrics. Principal component analysis (PCA), least squares-support vector machines (LS-SVM) and PCA-back propagation neural network (PCA-BPNN) models with the first and second derivative and standard normal variate (SNV) transformation pre-treatments were applied to classify soybean seeds based on genotype. Results demonstrated clear differences among glyphosate-resistant, hybrid descendants and conventional non-transformed soybean seeds could easily be visualized with an excellent classification (accuracy was 88.33% in validation set) using the LS-SVM and the spectra with SNV pre-treatment. The results indicated that THz spectroscopy techniques together with chemometrics would be a promising technique to distinguish transgenic soybean seeds from non-transformed seeds with high efficiency and without any major sample preparation.

  19. Detection and molecular characterization of Vibrio parahaemolyticus isolated from seafood harvested along the southwest coast of India.

    PubMed

    Raghunath, Pendru; Acharya, Sadananda; Bhanumathi, Amarbahadur; Karunasagar, Iddya; Karunasagar, Indrani

    2008-09-01

    The levels of total and tdh(+)Vibrio parahaemolyticus were estimated in 83 seafood samples from southwest coast of India by colony hybridization. Conventional enrichment and isolation technique was also used to study the prevalence. Polymerase chain reaction (PCR) was performed on bacterial cell lyates for detection of total and pathogenic V. parahaemolyticus by amplification of specific genes. Of 83 samples tested, V. parahaemolyticus could be detected in 74 (89.2%) samples and tdh(+)V. parahaemolyticus in 5 (6.0%) samples by colony hybridization. V. parahaemolyticus was detected in 68 (81.9%) of 83 samples after 18 h of enrichment by PCR, and isolated from 63 (75.9%) of 83 samples by conventional isolation. The virulence genes tdh and trh could be detected in 8.4% and 25.3%, respectively, in the sample enrichment broths by PCR. Use of colony hybridization following enrichment to achieve sensitive detection of tdh(+)V. parahaemolyticus in seafood was evaluated using another set of 58 seafood samples. Thirty pathogenic V. parahaemolyticus strains isolated during the study were screened by PCR for genetic markers to be specific for the detection of the pandemic clone. Results of this study suggest that the GS-PCR may serve as a reliable genetic marker for the pandemic clone of V. parahaemolyticus.

  20. A PCR technique to detect enterotoxigenic and verotoxigenic Escherichia coli in boar semen samples.

    PubMed

    Bussalleu, E; Pinart, E; Yeste, M; Briz, M; Sancho, S; Torner, E; Bonet, S

    2012-08-01

    In semen, bacteria's isolation from a pure culture is complex, laborious and easily alterable by the presence of antibiotics and inhibitors. We developed a PCR technique to detect the presence of the enterotoxigenic (ETEC) and verotoxigenic Escherichia coli (VTEC) (strains with high prevalence in the swine industry) in semen by adapting the protocols developed by Zhang et al. (2007) and Yilmaz et al. (2006). We artificially inoculated extended semen samples at different infective concentrations of bacteria (from 10(2) to 10(8) bacteria ml(-1)) with two enterotoxigenic and verotoxigenic strains, and performed two multiplex and one conventional PCR. This technique proved to be a quick, useful and reliable tool to detect the presence of ETEC and VTEC up to an infective dose of 10(5) bacteria ml(-1) in semen. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Stochastic Optical Reconstruction Microscopy (STORM).

    PubMed

    Xu, Jianquan; Ma, Hongqiang; Liu, Yang

    2017-07-05

    Super-resolution (SR) fluorescence microscopy, a class of optical microscopy techniques at a spatial resolution below the diffraction limit, has revolutionized the way we study biology, as recognized by the Nobel Prize in Chemistry in 2014. Stochastic optical reconstruction microscopy (STORM), a widely used SR technique, is based on the principle of single molecule localization. STORM routinely achieves a spatial resolution of 20 to 30 nm, a ten-fold improvement compared to conventional optical microscopy. Among all SR techniques, STORM offers a high spatial resolution with simple optical instrumentation and standard organic fluorescent dyes, but it is also prone to image artifacts and degraded image resolution due to improper sample preparation or imaging conditions. It requires careful optimization of all three aspects-sample preparation, image acquisition, and image reconstruction-to ensure a high-quality STORM image, which will be extensively discussed in this unit. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  2. Enhancing students’ mathematical problem posing skill through writing in performance tasks strategy

    NASA Astrophysics Data System (ADS)

    Kadir; Adelina, R.; Fatma, M.

    2018-01-01

    Many researchers have studied the Writing in Performance Task (WiPT) strategy in learning, but only a few paid attention on its relation to the problem-posing skill in mathematics. The problem-posing skill in mathematics covers problem reformulation, reconstruction, and imitation. The purpose of the present study was to examine the effect of WiPT strategy on students’ mathematical problem-posing skill. The research was conducted at a Public Junior Secondary School in Tangerang Selatan. It used a quasi-experimental method with randomized control group post-test. The samples were 64 students consists of 32 students of the experiment group and 32 students of the control. A cluster random sampling technique was used for sampling. The research data were obtained by testing. The research shows that the problem-posing skill of students taught by WiPT strategy is higher than students taught by a conventional strategy. The research concludes that the WiPT strategy is more effective in enhancing the students’ mathematical problem-posing skill compared to the conventional strategy.

  3. Application of ion-induced nucleation mass spectrometry in the analysis of trace gases evolved from a polyimide film during the thermal curing stages

    NASA Technical Reports Server (NTRS)

    Smith, A. C.

    1982-01-01

    Trace gases evolved from a polyimide film during its thermal curing stages have been studied using ion-induced nucleation mass spectrometry. The technique involved exposing the test gas sample to a low energy beta source and recording the masses of the ion-induced molecular clusters formed in the reaction chamber. On the basis of the experimentally observed molecular cluster spectra, it has been concluded that the dominant trace component had a molecular weight of 87 atomic mass units. This component has been identified as a molecule of dimethylacetamide (DMAC) which had been used as a solvent in the preparation of the test polyimide specimen. This identification has been further confirmed by comparing the spectra of the test gas sample and the DMAC calibration sample obtained with a conventional mass spectrometer. The advantages of the ion-induced nucleation mass spectrometer versus the conventional mass spectrometer are discussed.

  4. Isolation of potentially pathogenic fungi from selected pigeons' feeding sites in Karachi: A new dimension to health hazard.

    PubMed

    Naz, Sehar Afshan; Yaseen, Muhammad; Jabeen, Nusrat; Shafique, Maryam

    2017-06-01

    To determine the presence of pathogenic fungal strains in areas where pigeons are present in a large number. This study was conducted at the Federal Urdu University of Arts, Science and Technology, Karachi, from February 2015 to March2016, and comprised samples of soil contaminated with pigeons' excreta. The samples were collected from 20 different pigeon-feeding places in the city. These samples were processed for the isolation and identification of fungi by using standard conventional methods. The fungal strains isolated were also tested for their susceptibility to commonly used antifungal agents by disc diffusion technique. There were 105 samples. A wide variety of fungal strains belonging to different genera of Aspergillus, Rhizopus, Penicillium, Fusarium and Candida were isolated and identified by using conventional methods. The antifungal resistance pattern of these strains also depicts emergence of resistance against commonly used antifungal agents such as amphotericin B and fluconazole. The soil and air of places densely populated with pigeons were found to be loaded with fungal spores and many of them were potential pathogens.

  5. Polymerization Kinetics: Monitoring Monomer Conversion Using an Internal Standard and the Key Role of Sample "t[subscript 0]"

    ERIC Educational Resources Information Center

    Colombani, Olivier; Langelier, Ophelie; Martwong, Ekkachai; Castignolles, Patrice

    2011-01-01

    The use of an internal standard is a conventional and convenient way to monitor the conversion of one or several monomers during a controlled radical polymerization. However, the validity of this technique relies on an accurate determination of the initial monomer-to-internal standard ratio, A[subscript 0], because all subsequent calculations of…

  6. Thin sectioning and surface replication of ice at low temperature.

    USGS Publications Warehouse

    Daley, M.A.; Kirby, S.H.

    1984-01-01

    We have developed a new technique for making thin sections and surface replicas of ice at temperatures well below 273d K. The ability to make thin sections without melting sample material is important in textural and microstructural studies of ice deformed at low temperatures because of annealing effects we have observed during conventional section making.-from Author

  7. Robust reconstruction of time-resolved diffraction from ultrafast streak cameras

    PubMed Central

    Badali, Daniel S.; Dwayne Miller, R. J.

    2017-01-01

    In conjunction with ultrafast diffraction, streak cameras offer an unprecedented opportunity for recording an entire molecular movie with a single probe pulse. This is an attractive alternative to conventional pump-probe experiments and opens the door to studying irreversible dynamics. However, due to the “smearing” of the diffraction pattern across the detector, the streaking technique has thus far been limited to simple mono-crystalline samples and extreme care has been taken to avoid overlapping diffraction spots. In this article, this limitation is addressed by developing a general theory of streaking of time-dependent diffraction patterns. Understanding the underlying physics of this process leads to the development of an algorithm based on Bayesian analysis to reconstruct the time evolution of the two-dimensional diffraction pattern from a single streaked image. It is demonstrated that this approach works on diffraction peaks that overlap when streaked, which not only removes the necessity of carefully choosing the streaking direction but also extends the streaking technique to be able to study polycrystalline samples and materials with complex crystalline structures. Furthermore, it is shown that the conventional analysis of streaked diffraction can lead to erroneous interpretations of the data. PMID:28653022

  8. Discrepancy between culture and DNA probe analysis for the detection of periodontal bacteria.

    PubMed

    van Steenbergen, T J; Timmerman, M F; Mikx, F H; de Quincey, G; van der Weijden, G A; van der Velden, U; de Graaff, J

    1996-10-01

    The purpose of this study was to compare a commercially available DNA probe technique with conventional cultural techniques for the detection of Actinobacillus actinomycetemcomitans, Porphyromonas gingivalis and Prevotella intermedia in subgingival plaque samples. Samples from 20 patients with moderate to severe periodontitis were evaluated at baseline and during a 15 months period of periodontal treatment. Paperpoints from 4 periodontal pockets per patient were forwarded to Omnigene for DNA probe analysis, and simultaneously inserted paperpoints from the same pockets were analyzed by standard culture techniques. In addition, mixed bacterial samples were constructed harbouring known proportions of 25 strains of A. actinomycetemcomitans, P. gingivalis and P. intermedia each. A relatively low concordance was found between both methods. At baseline a higher detection frequency was found for A. actinomycetemcomitans and P. gingivalis for the DNA probe technique; for P. intermedia the detection frequency by culture was higher. For A. actinomycetemcomitans, 21% of the culture positive samples was positive with the DNA probe. Testing the constructed bacterial samples with the DNA probe method resulted in about 16% false positive results for the 3 species tested. Furthermore, 40% of P. gingivalis strains were not detected by the DNA probe. The present data suggest that at least part of the discrepancies found between the DNA probe technique used and cultural methods are caused by false positive and false negative DNA probe results. Therefore, the value of this DNA probe method for the detection of periodontal pathogens is questionable.

  9. GMO detection using a bioluminescent real time reporter (BART) of loop mediated isothermal amplification (LAMP) suitable for field use.

    PubMed

    Kiddle, Guy; Hardinge, Patrick; Buttigieg, Neil; Gandelman, Olga; Pereira, Clint; McElgunn, Cathal J; Rizzoli, Manuela; Jackson, Rebecca; Appleton, Nigel; Moore, Cathy; Tisi, Laurence C; Murray, James A H

    2012-04-30

    There is an increasing need for quantitative technologies suitable for molecular detection in a variety of settings for applications including food traceability and monitoring of genetically modified (GM) crops and their products through the food processing chain. Conventional molecular diagnostics utilising real-time polymerase chain reaction (RT-PCR) and fluorescence-based determination of amplification require temperature cycling and relatively complex optics. In contrast, isothermal amplification coupled to a bioluminescent output produced in real-time (BART) occurs at a constant temperature and only requires a simple light detection and integration device. Loop mediated isothermal amplification (LAMP) shows robustness to sample-derived inhibitors. Here we show the applicability of coupled LAMP and BART reactions (LAMP-BART) for determination of genetically modified (GM) maize target DNA at low levels of contamination (0.1-5.0% GM) using certified reference material, and compare this to RT-PCR. Results show that conventional DNA extraction methods developed for PCR may not be optimal for LAMP-BART quantification. Additionally, we demonstrate that LAMP is more tolerant to plant sample-derived inhibitors, and show this can be exploited to develop rapid extraction techniques suitable for simple field-based qualitative tests for GM status determination. We also assess the effect of total DNA assay load on LAMP-BART quantitation. LAMP-BART is an effective and sensitive technique for GM detection with significant potential for quantification even at low levels of contamination and in samples derived from crops such as maize with a large genome size. The resilience of LAMP-BART to acidic polysaccharides makes it well suited to rapid sample preparation techniques and hence to both high throughput laboratory settings and to portable GM detection applications. The impact of the plant sample matrix and genome loading within a reaction must be controlled to ensure quantification at low target concentrations.

  10. Evaluation of the Accuracy of Conventional and Digital Impression Techniques for Implant Restorations.

    PubMed

    Moura, Renata Vasconcellos; Kojima, Alberto Noriyuki; Saraceni, Cintia Helena Coury; Bassolli, Lucas; Balducci, Ivan; Özcan, Mutlu; Mesquita, Alfredo Mikail Melo

    2018-05-01

    The increased use of CAD systems can generate doubt about the accuracy of digital impressions for angulated implants. The aim of this study was to evaluate the accuracy of different impression techniques, two conventional and one digital, for implants with and without angulation. We used a polyurethane cast that simulates the human maxilla according to ASTM F1839, and 6 tapered implants were installed with external hexagonal connections to simulate tooth positions 17, 15, 12, 23, 25, and 27. Implants 17 and 23 were placed with 15° of mesial angulation and distal angulation, respectively. Mini cone abutments were installed on these implants with a metal strap 1 mm in height. Conventional and digital impression procedures were performed on the maxillary master cast, and the implants were separated into 6 groups based on the technique used and measurement type: G1 - control, G2 - digital impression, G3 - conventional impression with an open tray, G4 - conventional impression with a closed tray, G5 - conventional impression with an open tray and a digital impression, and G6 - conventional impression with a closed tray and a digital impression. A statistical analysis was performed using two-way repeated measures ANOVA to compare the groups, and a Kruskal-Wallis test was conducted to analyze the accuracy of the techniques. No significant difference in the accuracy of the techniques was observed between the groups. Therefore, no differences were found among the conventional impression and the combination of conventional and digital impressions, and the angulation of the implants did not affect the accuracy of the techniques. All of the techniques exhibited trueness and had acceptable precision. The variation of the angle of the implants did not affect the accuracy of the techniques. © 2018 by the American College of Prosthodontists.

  11. Nuclear Ensemble Approach with Importance Sampling.

    PubMed

    Kossoski, Fábris; Barbatti, Mario

    2018-06-12

    We show that the importance sampling technique can effectively augment the range of problems where the nuclear ensemble approach can be applied. A sampling probability distribution function initially determines the collection of initial conditions for which calculations are performed, as usual. Then, results for a distinct target distribution are computed by introducing compensating importance sampling weights for each sampled point. This mapping between the two probability distributions can be performed whenever they are both explicitly constructed. Perhaps most notably, this procedure allows for the computation of temperature dependent observables. As a test case, we investigated the UV absorption spectra of phenol, which has been shown to have a marked temperature dependence. Application of the proposed technique to a range that covers 500 K provides results that converge to those obtained with conventional sampling. We further show that an overall improved rate of convergence is obtained when sampling is performed at intermediate temperatures. The comparison between calculated and the available measured cross sections is very satisfactory, as the main features of the spectra are correctly reproduced. As a second test case, one of Tully's classical models was revisited, and we show that the computation of dynamical observables also profits from the importance sampling technique. In summary, the strategy developed here can be employed to assess the role of temperature for any property calculated within the nuclear ensemble method, with the same computational cost as doing so for a single temperature.

  12. Advanced functional materials in solid phase extraction for ICP-MS determination of trace elements and their species - A review.

    PubMed

    He, Man; Huang, Lijin; Zhao, Bingshan; Chen, Beibei; Hu, Bin

    2017-06-22

    For the determination of trace elements and their species in various real samples by inductively coupled plasma mass spectrometry (ICP-MS), solid phase extraction (SPE) is a commonly used sample pretreatment technique to remove complex matrix, pre-concentrate target analytes and make the samples suitable for subsequent sample introduction and measurements. The sensitivity, selectivity/anti-interference ability, sample throughput and application potential of the methodology of SPE-ICP-MS are greatly dependent on SPE adsorbents. This article presents a general overview of the use of advanced functional materials (AFMs) in SPE for ICP-MS determination of trace elements and their species in the past decade. Herein the AFMs refer to the materials featuring with high adsorption capacity, good selectivity, fast adsorption/desorption dynamics and satisfying special requirements in real sample analysis, including nanometer-sized materials, porous materials, ion imprinting polymers, restricted access materials and magnetic materials. Carbon/silica/metal/metal oxide nanometer-sized adsorbents with high surface area and plenty of adsorption sites exhibit high adsorption capacity, and porous adsorbents would provide more adsorption sites and faster adsorption dynamics. The selectivity of the materials for target elements/species can be improved by using physical/chemical modification, ion imprinting and restricted accessed technique. Magnetic adsorbents in conventional batch operation offer unique magnetic response and high surface area-volume ratio which provide a very easy phase separation, greater extraction capacity and efficiency over conventional adsorbents, and chip-based magnetic SPE provides a versatile platform for special requirement (e.g. cell analysis). The performance of these adsorbents for the determination of trace elements and their species in different matrices by ICP-MS is discussed in detail, along with perspectives and possible challenges in the future development. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. 3D imaging of optically cleared tissue using a simplified CLARITY method and on-chip microscopy

    PubMed Central

    Zhang, Yibo; Shin, Yoonjung; Sung, Kevin; Yang, Sam; Chen, Harrison; Wang, Hongda; Teng, Da; Rivenson, Yair; Kulkarni, Rajan P.; Ozcan, Aydogan

    2017-01-01

    High-throughput sectioning and optical imaging of tissue samples using traditional immunohistochemical techniques can be costly and inaccessible in resource-limited areas. We demonstrate three-dimensional (3D) imaging and phenotyping in optically transparent tissue using lens-free holographic on-chip microscopy as a low-cost, simple, and high-throughput alternative to conventional approaches. The tissue sample is passively cleared using a simplified CLARITY method and stained using 3,3′-diaminobenzidine to target cells of interest, enabling bright-field optical imaging and 3D sectioning of thick samples. The lens-free computational microscope uses pixel super-resolution and multi-height phase recovery algorithms to digitally refocus throughout the cleared tissue and obtain a 3D stack of complex-valued images of the sample, containing both phase and amplitude information. We optimized the tissue-clearing and imaging system by finding the optimal illumination wavelength, tissue thickness, sample preparation parameters, and the number of heights of the lens-free image acquisition and implemented a sparsity-based denoising algorithm to maximize the imaging volume and minimize the amount of the acquired data while also preserving the contrast-to-noise ratio of the reconstructed images. As a proof of concept, we achieved 3D imaging of neurons in a 200-μm-thick cleared mouse brain tissue over a wide field of view of 20.5 mm2. The lens-free microscope also achieved more than an order-of-magnitude reduction in raw data compared to a conventional scanning optical microscope imaging the same sample volume. Being low cost, simple, high-throughput, and data-efficient, we believe that this CLARITY-enabled computational tissue imaging technique could find numerous applications in biomedical diagnosis and research in low-resource settings. PMID:28819645

  14. Ultratrace level determination and quantitative analysis of kidney injury biomarkers in patient samples attained by zinc oxide nanorods

    NASA Astrophysics Data System (ADS)

    Singh, Manpreet; Alabanza, Anginelle; Gonzalez, Lorelis E.; Wang, Weiwei; Reeves, W. Brian; Hahm, Jong-In

    2016-02-01

    Determining ultratrace amounts of protein biomarkers in patient samples in a straightforward and quantitative manner is extremely important for early disease diagnosis and treatment. Here, we successfully demonstrate the novel use of zinc oxide nanorods (ZnO NRs) in the ultrasensitive and quantitative detection of two acute kidney injury (AKI)-related protein biomarkers, tumor necrosis factor (TNF)-α and interleukin (IL)-8, directly from patient samples. We first validate the ZnO NRs-based IL-8 results via comparison with those obtained from using a conventional enzyme-linked immunosorbent method in samples from 38 individuals. We further assess the full detection capability of the ZnO NRs-based technique by quantifying TNF-α, whose levels in human urine are often below the detection limits of conventional methods. Using the ZnO NR platforms, we determine the TNF-α concentrations of all 46 patient samples tested, down to the fg per mL level. Subsequently, we screen for TNF-α levels in approximately 50 additional samples collected from different patient groups in order to demonstrate a potential use of the ZnO NRs-based assay in assessing cytokine levels useful for further clinical monitoring. Our research efforts demonstrate that ZnO NRs can be straightforwardly employed in the rapid, ultrasensitive, quantitative, and simultaneous detection of multiple AKI-related biomarkers directly in patient urine samples, providing an unparalleled detection capability beyond those of conventional analysis methods. Additional key advantages of the ZnO NRs-based approach include a fast detection speed, low-volume assay condition, multiplexing ability, and easy automation/integration capability to existing fluorescence instrumentation. Therefore, we anticipate that our ZnO NRs-based detection method will be highly beneficial for overcoming the frequent challenges in early biomarker development and treatment assessment, pertaining to the facile and ultrasensitive quantification of hard-to-trace biomolecules.Determining ultratrace amounts of protein biomarkers in patient samples in a straightforward and quantitative manner is extremely important for early disease diagnosis and treatment. Here, we successfully demonstrate the novel use of zinc oxide nanorods (ZnO NRs) in the ultrasensitive and quantitative detection of two acute kidney injury (AKI)-related protein biomarkers, tumor necrosis factor (TNF)-α and interleukin (IL)-8, directly from patient samples. We first validate the ZnO NRs-based IL-8 results via comparison with those obtained from using a conventional enzyme-linked immunosorbent method in samples from 38 individuals. We further assess the full detection capability of the ZnO NRs-based technique by quantifying TNF-α, whose levels in human urine are often below the detection limits of conventional methods. Using the ZnO NR platforms, we determine the TNF-α concentrations of all 46 patient samples tested, down to the fg per mL level. Subsequently, we screen for TNF-α levels in approximately 50 additional samples collected from different patient groups in order to demonstrate a potential use of the ZnO NRs-based assay in assessing cytokine levels useful for further clinical monitoring. Our research efforts demonstrate that ZnO NRs can be straightforwardly employed in the rapid, ultrasensitive, quantitative, and simultaneous detection of multiple AKI-related biomarkers directly in patient urine samples, providing an unparalleled detection capability beyond those of conventional analysis methods. Additional key advantages of the ZnO NRs-based approach include a fast detection speed, low-volume assay condition, multiplexing ability, and easy automation/integration capability to existing fluorescence instrumentation. Therefore, we anticipate that our ZnO NRs-based detection method will be highly beneficial for overcoming the frequent challenges in early biomarker development and treatment assessment, pertaining to the facile and ultrasensitive quantification of hard-to-trace biomolecules. Electronic supplementary information (ESI) available: Typical SEM images of the ZnO NRs used in the biomarker assays are provided in Fig. S1. See DOI: 10.1039/c5nr08706f

  15. Xpert® MTB/RIF: Usefulness for the diagnosis of tuberculosis and resistance to rifampicin.

    PubMed

    Vergara Gómez, Andrea; González-Martín, Julià; García-Basteiro, Alberto L

    2017-11-09

    The advent of the Xpert® MTB/RIF technique was a revolution in the diagnosis of tuberculosis, especially in areas with high incidence and low resources. It allows the detection of Mycobacterium tuberculosis complex and simultaneously the most common resistance mutations to rifampicin in less than 2h. For respiratory samples the sensitivity is very high, but it decreases for extrapulmonary samples and children. Although it is faster and simpler than conventional methods, it presents some limitations and new and better techniques are needed to reduce the number of cases and deaths caused by tuberculosis. This review aims to assess the scientific evidence around the diagnostic performance of Xpert® MTB/RIF in different types of samples and populations, as well as analyse its strengths and limitations for TB diagnosis. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  16. On-line concentration and determination of all-trans- and 13-cis- retinoic acids in rabbit serum by application of sweeping technique in micellar electrokinetic chromatography.

    PubMed

    Zhao, Yongxi; Kong, Yu; Wang, Bo; Wu, Yayan; Wu, Hong

    2007-03-30

    A simple and rapid micellar electrokinetic chromatography (MEKC) method with UV detection was developed for the simultaneous separation and determination of all-trans- and 13-cis-retinoic acids in rabbit serum by on-line sweeping concentration technique. The serum sample was simply deproteinized and centrifuged. Various parameters affecting sample enrichment and separation were systematically investigated. Under optimal conditions, the analytes could be well separated within 17min, and the relative standard deviations (RSD) of migration times and peak areas were less than 3.4%. Compared with the conventional MEKC injection method, the 18- and 19-fold improvements in sensitivity were achieved, respectively. The proposed method has been successfully applied to the determination of all-trans- and 13-cis-retinoic acids in serum samples from rabbits and could be feasible for the further pharmacokinetics study of all-trans-retinoic acid.

  17. SRRF: Universal live-cell super-resolution microscopy.

    PubMed

    Culley, Siân; Tosheva, Kalina L; Matos Pereira, Pedro; Henriques, Ricardo

    2018-08-01

    Super-resolution microscopy techniques break the diffraction limit of conventional optical microscopy to achieve resolutions approaching tens of nanometres. The major advantage of such techniques is that they provide resolutions close to those obtainable with electron microscopy while maintaining the benefits of light microscopy such as a wide palette of high specificity molecular labels, straightforward sample preparation and live-cell compatibility. Despite this, the application of super-resolution microscopy to dynamic, living samples has thus far been limited and often requires specialised, complex hardware. Here we demonstrate how a novel analytical approach, Super-Resolution Radial Fluctuations (SRRF), is able to make live-cell super-resolution microscopy accessible to a wider range of researchers. We show its applicability to live samples expressing GFP using commercial confocal as well as laser- and LED-based widefield microscopes, with the latter achieving long-term timelapse imaging with minimal photobleaching. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Efficacy of the FilmArray blood culture identification panel for direct molecular diagnosis of infectious diseases from samples other than blood.

    PubMed

    Micó, Miquel; Navarro, Ferran; de Miniac, Daniela; González, Yésica; Brell, Albert; López, Cristina; Sánchez-Reus, Ferran; Mirelis, Beatriz; Coll, Pere

    2015-12-01

    Molecular-based techniques reduce the delay in diagnosing infectious diseases and therefore contribute to better patient outcomes. We assessed the FilmArray blood culture identification (BCID) panel (Biofire Diagnostics/bioMérieux) directly on clinical specimens other than blood: cerebrospinal, joint, pleural and ascitic fluids, bronchoscopy samples and abscesses. We compared the results from 88 samples obtained by culture-based techniques. The percentage of agreement between the two methods was 75 % with a Cohen κ value of 0.51. Global sensitivity and specificity using the FilmArray BCID panel were 71 and 97 %, respectively. Sensitivity was poorer in samples with a low bacterial load, such as ascitic and pleural fluids (25 %), whereas the sensitivity for abscess samples was high (89 %). These findings suggest that the FilmArray BCID panel could be useful to perform microbiological diagnosis directly from samples other than positive blood cultures, as it offers acceptable sensitivity and moderate agreement with conventional microbiological methods. Nevertheless, cost-benefit studies should be performed before introducing this method into algorithms for microbiological diagnostics.

  19. Direct analysis of herbal powders by pipette-tip electrospray ionization mass spectrometry.

    PubMed

    Wang, Haixing; So, Pui-Kin; Yao, Zhong-Ping

    2014-01-27

    Conventional electrospray ionization mass spectrometry (ESI-MS) is widely used for analysis of solution samples. The development of solid-substrate ESI-MS allows direct ionization analysis of bulky solid samples. In this study, we developed pipette-tip ESI-MS, a technique that combines pipette tips with syringe and syringe pump, for direct analysis of herbal powders, another common form of samples. We demonstrated that various herbal powder samples, including herbal medicines and food samples, could be readily online extracted and analyzed using this technique. Various powder samples, such as Rhizoma coptidis, lotus plumule, great burdock achene, black pepper, Panax ginseng, roasted coffee beans, Fructus Schisandrae Chinensis and Fructus Schisandrae Sphenantherae, were analyzed using pipette-tip ESI-MS and quality mass spectra with stable and durable signals could be obtained. Both positive and negative ion modes were attempted and various compounds including amino acids, oligosaccharides, glycosides, alkaloids, organic acids, ginosensides, flavonoids and lignans could be detected. Principal component analysis (PCA) based on the acquired mass spectra allowed rapid differentiation of closely related herbal species. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. A Comparative Evaluation of the Effect of Double Casting Technique Using Functionally Generated Path and Conventional Single Casting with Respect to Functional Articulation, Patient Satisfaction and Chair Side Time, in Single Unit Molar Teeth: An In Vivo Study.

    PubMed

    Memon, Sarfaraz

    2014-12-01

    A stable centric occlusal position that shows no evidence of occlusal disease should not be altered. Confirmative restorative dentistry deals with making restorations that are in harmony with existing jaw relations. Conventional techniques for construction have been unsuccessful in producing a prosthesis that can be inserted without minor intraoral occlusal adjustment. This study was conducted to evaluate the benefits of the double casting technique with FGP over the conventional casting technique. Ten patients with root canal treated maxillary molar were selected for the fabrication of metal crown. Two techniques, one involving the conventional fabrication and other using functionally generated path with double casting were used to fabricate the prosthesis. A comparison based on various parameters which was done between the two techniques. The change in the height of castings for the double casting group was less compared to the conventional group and was highly statistically significant (P < 0.001). The time taken for occlusal correction was significantly lower in double casting group than the conventional group (P < 0.001). The patient satisfaction (before occlusal correction) indicated better satisfaction for double casting group compared to conventional (P < 0.01). The functionally generated path with double casting technique resulted in castings which had better dimensional accuracy, less occlusal correction and better patient satisfaction compared to the conventional castings.

  1. The rapid measurement of soil carbon stock using near-infrared technology

    NASA Astrophysics Data System (ADS)

    Kusumo, B. H.; Sukartono; Bustan

    2018-03-01

    As a soil pool stores carbon (C) three times higher than an atmospheric pool, the depletion of C stock in the soil will significantly increase the concentration of CO2 in the atmosphere, causing global warming. However, the monitoring or measurement of soil C stock using conventional procedures is time-consuming and expensive. So it requires a rapid and non-destructive technique that is simple and does not need chemical substances. This research is aimed at testing whether near-infrared (NIR) technology is able to rapidly measure C stock in the soil. Soil samples were collected from an agricultural land at the sub-district of Kayangan, North Lombok, Indonesia. The coordinates of the samples were recorded. Parts of the samples were analyzed using conventional procedure (Walkley and Black) and some other parts were scanned using near-infrared spectroscopy (NIRS) for soil spectral collection. Partial Least Square Regression (PLSR) was used to develop models from soil C data measured by conventional analysis and from spectral data scanned by NIRS. The best model was moderately successful to measure soil C stock in the study area in North Lombok. This indicates that the NIR technology can be further used to monitor the change of soil C stock in the soil.

  2. A New Technique for Measuring Concentration Dependence of Self and Collective Diffusivity by using a Single Sample

    NASA Astrophysics Data System (ADS)

    Sirorattanakul, Krittanon; Shen, Chong; Ou-Yang, Daniel

    Diffusivity governs the dynamics of interacting particles suspended in a solvent. At high particle concentration, the interactions between particles become non-negligible, making the values of self and collective diffusivity diverge and concentration-dependent. Conventional methods for measuring this dependency, such as forced Rayleigh scattering, fluorescence correlation spectroscopy (FCS), and dynamic light scattering (DLS) require preparation of multiple samples. We present a new technique to measure this dependency by using only a single sample. Dielectrophoresis (DEP) is used to create concentration gradient in the solution. Across this concentration distribution, we use FCS to measure the concentration-dependent self diffusivity. Then, we switch off DEP to allow the particles to diffuse back to equilibrium. We obtain the time series of concentration distribution from fluorescence microscopy and use them to determine the concentration-dependent collective diffusivity. We compare the experimental results with computer simulations to verify the validity of this technique. Time and spatial resolution limits of FCS and imaging are also analyzed to estimate the limitation of the proposed technique. NSF DMR-0923299, Lehigh College of Arts and Sciences Undergraduate Research Grant, Lehigh Department of Physics, Emulsion Polymers Institute.

  3. A diagnostic analysis of the VVP single-doppler retrieval technique

    NASA Technical Reports Server (NTRS)

    Boccippio, Dennis J.

    1995-01-01

    A diagnostic analysis of the VVP (volume velocity processing) retrieval method is presented, with emphasis on understanding the technique as a linear, multivariate regression. Similarities and differences to the velocity-azimuth display and extended velocity-azimuth display retrieval techniques are discussed, using this framework. Conventional regression diagnostics are then employed to quantitatively determine situations in which the VVP technique is likely to fail. An algorithm for preparation and analysis of a robust VVP retrieval is developed and applied to synthetic and actual datasets with high temporal and spatial resolution. A fundamental (but quantifiable) limitation to some forms of VVP analysis is inadequate sampling dispersion in the n space of the multivariate regression, manifest as a collinearity between the basis functions of some fitted parameters. Such collinearity may be present either in the definition of these basis functions or in their realization in a given sampling configuration. This nonorthogonality may cause numerical instability, variance inflation (decrease in robustness), and increased sensitivity to bias from neglected wind components. It is shown that these effects prevent the application of VVP to small azimuthal sectors of data. The behavior of the VVP regression is further diagnosed over a wide range of sampling constraints, and reasonable sector limits are established.

  4. Effect of Chemistry Triangle Oriented Learning Media on Cooperative, Individual and Conventional Method on Chemistry Learning Result

    NASA Astrophysics Data System (ADS)

    Latisma D, L.; Kurniawan, W.; Seprima, S.; Nirbayani, E. S.; Ellizar, E.; Hardeli, H.

    2018-04-01

    The purpose of this study was to see which method are well used with the Chemistry Triangle-oriented learning media. This quasi experimental research involves first grade of senior high school students in six schools namely each two SMA N in Solok city, in Pasaman and two SMKN in Pariaman. The sampling technique was done by Cluster Random Sampling. Data were collected by test and analyzed by one-way anova and Kruskall Wallish test. The results showed that the high school students in Solok learning taught by cooperative method is better than the results of student learning taught by conventional and Individual methods, both for students who have high initial ability and low-ability. Research in SMK showed that the overall student learning outcomes taught by conventional method is better than the student learning outcomes taught by cooperative and individual methods. Student learning outcomes that have high initial ability taught by individual method is better than student learning outcomes that are taught by cooperative method and for students who have low initial ability, there is no difference in student learning outcomes taught by cooperative, individual and conventional methods. Learning in high school in Pasaman showed no significant difference in learning outcomes of the three methods undertaken.

  5. 4D (x-y-z-t) imaging of thick biological samples by means of Two-Photon inverted Selective Plane Illumination Microscopy (2PE-iSPIM)

    PubMed Central

    Lavagnino, Zeno; Sancataldo, Giuseppe; d’Amora, Marta; Follert, Philipp; De Pietri Tonelli, Davide; Diaspro, Alberto; Cella Zanacchi, Francesca

    2016-01-01

    In the last decade light sheet fluorescence microscopy techniques, such as selective plane illumination microscopy (SPIM), has become a well established method for developmental biology. However, conventional SPIM architectures hardly permit imaging of certain tissues since the common sample mounting procedure, based on gel embedding, could interfere with the sample morphology. In this work we propose an inverted selective plane microscopy system (iSPIM), based on non-linear excitation, suitable for 3D tissue imaging. First, the iSPIM architecture provides flexibility on the sample mounting, getting rid of the gel-based mounting typical of conventional SPIM, permitting 3D imaging of hippocampal slices from mouse brain. Moreover, all the advantages brought by two photon excitation (2PE) in terms of reduction of scattering effects and contrast improvement are exploited, demonstrating an improved image quality and contrast compared to single photon excitation. The system proposed represents an optimal platform for tissue imaging and it smooths the way to the applicability of light sheet microscopy to a wider range of samples including those that have to be mounted on non-transparent surfaces. PMID:27033347

  6. Comparison of digital and conventional impression techniques: evaluation of patients' perception, treatment comfort, effectiveness and clinical outcomes.

    PubMed

    Yuzbasioglu, Emir; Kurt, Hanefi; Turunc, Rana; Bilir, Halenur

    2014-01-30

    The purpose of this study was to compare two impression techniques from the perspective of patient preferences and treatment comfort. Twenty-four (12 male, 12 female) subjects who had no previous experience with either conventional or digital impression participated in this study. Conventional impressions of maxillary and mandibular dental arches were taken with a polyether impression material (Impregum, 3 M ESPE), and bite registrations were made with polysiloxane bite registration material (Futar D, Kettenbach). Two weeks later, digital impressions and bite scans were performed using an intra-oral scanner (CEREC Omnicam, Sirona). Immediately after the impressions were made, the subjects' attitudes, preferences and perceptions towards impression techniques were evaluated using a standardized questionnaire. The perceived source of stress was evaluated using the State-Trait Anxiety Scale. Processing steps of the impression techniques (tray selection, working time etc.) were recorded in seconds. Statistical analyses were performed with the Wilcoxon Rank test, and p < 0.05 was considered significant. There were significant differences among the groups (p < 0.05) in terms of total working time and processing steps. Patients stated that digital impressions were more comfortable than conventional techniques. Digital impressions resulted in a more time-efficient technique than conventional impressions. Patients preferred the digital impression technique rather than conventional techniques.

  7. The Detection Method of Escherichia coli in Water Resources: A Review

    NASA Astrophysics Data System (ADS)

    Nurliyana, M. R.; Sahdan, M. Z.; Wibowo, K. M.; Muslihati, A.; Saim, H.; Ahmad, S. A.; Sari, Y.; Mansor, Z.

    2018-04-01

    This article reviews several approaches for Escherichia coli (E. coli) bacteria detection from conventional methods, emerging method and goes to biosensor-based techniques. Detection and enumeration of E. coli bacteria usually required long duration of time in obtaining the result since laboratory-based approach is normally used in its assessment. It requires 24 hours to 72 hours after sampling to process the culturing samples before results are available. Although faster technique for detecting E. coli in water such as Polymerase Chain Reaction (PCR) and Enzyme-Linked Immunosorbent Assay (ELISA) have been developed, it still required transporting the samples from water resources to the laboratory, high-cost, complicated equipment usage, complex procedures, as well as the requirement of skilled specialist to cope with the complexity which limit their wide spread practice in water quality detection. Recently, development of biosensor device that is easy to perform, portable, highly sensitive and selective becomes indispensable in detecting extremely lower consolidation of pathogenic E. coli bacteria in water samples.

  8. Space-resolved diffusing wave spectroscopy measurements of the macroscopic deformation and the microscopic dynamics in tensile strain tests

    NASA Astrophysics Data System (ADS)

    Nagazi, Med-Yassine; Brambilla, Giovanni; Meunier, Gérard; Marguerès, Philippe; Périé, Jean-Noël; Cipelletti, Luca

    2017-01-01

    We couple a laser-based, space-resolved dynamic light scattering apparatus to a universal traction machine for mechanical extensional tests. We perform simultaneous optical and mechanical measurements on polyether ether ketone, a semi-crystalline polymer widely used in the industry. Due to the high turbidity of the sample, light is multiply scattered by the sample and the diffusing wave spectroscopy (DWS) formalism is used to interpret the data. Space-resolved DWS yields spatial maps of the sample strain and of the microscopic dynamics. An excellent agreement is found between the strain maps thus obtained and those measured by a conventional stereo-digital image correlation technique. The microscopic dynamics reveals both affine motion and plastic rearrangements. Thanks to the extreme sensitivity of DWS to displacements as small as 1 nm, plastic activity and its spatial localization can be detected at an early stage of the sample strain, making the technique presented here a valuable complement to existing material characterization methods.

  9. Data precision of X-ray fluorescence (XRF) scanning of discrete samples with the ITRAX XRF core-scanner exemplified on loess-paleosol samples

    NASA Astrophysics Data System (ADS)

    Profe, Jörn; Ohlendorf, Christian

    2017-04-01

    XRF-scanning is the state-of-the-art technique for geochemical analyses in marine and lacustrine sedimentology for more than a decade. However, little attention has been paid to data precision and technical limitations so far. Using homogenized, dried and powdered samples (certified geochemical reference standards and samples from a lithologically-contrasting loess-paleosol sequence) minimizes many adverse effects that influence the XRF-signal when analyzing wet sediment cores. This allows the investigation of data precision under ideal conditions and documents a new application of the XRF core-scanner technology at the same time. Reliable interpretations of XRF results require data precision evaluation of single elements as a function of X-ray tube, measurement time, sample compaction and quality of peak fitting. Ten-fold measurement of each sample constitutes data precision. Data precision of XRF measurements theoretically obeys Poisson statistics. Fe and Ca exhibit largest deviations from Poisson statistics. The same elements show the least mean relative standard deviations in the range from 0.5% to 1%. This represents the technical limit of data precision achievable by the installed detector. Measurement times ≥ 30 s reveal mean relative standard deviations below 4% for most elements. The quality of peak fitting is only relevant for elements with overlapping fluorescence lines such as Ba, Ti and Mn or for elements with low concentrations such as Y, for example. Differences in sample compaction are marginal and do not change mean relative standard deviation considerably. Data precision is in the range reported for geochemical reference standards measured by conventional techniques. Therefore, XRF scanning of discrete samples provide a cost- and time-efficient alternative to conventional multi-element analyses. As best trade-off between economical operation and data quality, we recommend a measurement time of 30 s resulting in a total scan time of 30 minutes for 30 samples.

  10. Approaches to Recruiting ‘Hard-To-Reach’ Populations into Re­search: A Review of the Literature

    PubMed Central

    Shaghaghi, Abdolreza; Bhopal, Raj S; Sheikh, Aziz

    2011-01-01

    Background: ‘Hard-to-reach’ is a term used to describe those sub-groups of the population that may be difficult to reach or involve in research or public health programmes. Application of a single term to call these sub-sections of populations implies a homogeneity within distinct groups, which does not necessarily exist. Different sampling techniques were introduced so far to recruit hard-to-reach populations. In this article, we have reviewed a range of ap­proaches that have been used to widen participation in studies. Methods: We performed a Pubmed and Google search for relevant English language articles using the keywords and phrases: (hard-to-reach AND population* OR sampl*), (hidden AND population* OR sample*) and (“hard to reach” AND population* OR sample*) and a consul­tation of the retrieved articles’ bibliographies to extract empirical evidence from publications that discussed or examined the use of sampling techniques to recruit hidden or hard-to-reach populations in health studies. Results: Reviewing the literature has identified a range of techniques to recruit hard-to-reach populations, including snowball sampling, respondent-driven sampling (RDS), indigenous field worker sampling (IFWS), facility-based sampling (FBS), targeted sampling (TS), time-location (space) sampling (TLS), conventional cluster sampling (CCS) and capture re-capture sampling (CR). Conclusion: The degree of compliance with a study by a certain ‘hard-to-reach’ group de­pends on the characteristics of that group, recruitment technique used and the subject of inter­est. Irrespective of potential advantages or limitations of the recruitment techniques reviewed, their successful use depends mainly upon our knowledge about specific characteristics of the target populations. Thus in line with attempts to expand the current boundaries of our know­ledge about recruitment techniques in health studies and their applications in varying situa­tions, we should also focus on possibly all contributing factors which may have an impact on participation rate within a defined population group. PMID:24688904

  11. Single-tube analysis of DNA methylation with silica superparamagnetic beads.

    PubMed

    Bailey, Vasudev J; Zhang, Yi; Keeley, Brian P; Yin, Chao; Pelosky, Kristen L; Brock, Malcolm; Baylin, Stephen B; Herman, James G; Wang, Tza-Huei

    2010-06-01

    DNA promoter methylation is a signature for the silencing of tumor suppressor genes. Most widely used methods to detect DNA methylation involve 3 separate, independent processes: DNA extraction, bisulfite conversion, and methylation detection via a PCR method, such as methylation-specific PCR (MSP). This method includes many disconnected steps with associated losses of material, potentially reducing the analytical sensitivity required for analysis of challenging clinical samples. Methylation on beads (MOB) is a new technique that integrates DNA extraction, bisulfite conversion, and PCR in a single tube via the use of silica superparamagnetic beads (SSBs) as a common DNA carrier for facilitating cell debris removal and buffer exchange throughout the entire process. In addition, PCR buffer is used to directly elute bisulfite-treated DNA from SSBs for subsequent target amplifications. The diagnostic sensitivity of MOB was evaluated by methylation analysis of the CDKN2A [cyclin-dependent kinase inhibitor 2A (melanoma, p16, inhibits CDK4); also known as p16(INK4a)] promoter in serum DNA of lung cancer patients and compared with that of conventional methods. Methylation analysis consisting of DNA extraction followed by bisulfite conversion and MSP was successfully carried out within 9 h in a single tube. The median pre-PCR DNA yield was 6.61-fold higher with the MOB technique than with conventional techniques. Furthermore, MOB increased the diagnostic sensitivity in our analysis of the CDKN2A promoter in patient serum by successfully detecting methylation in 74% of cancer patients, vs the 45% detection rate obtained with conventional techniques. The MOB technique successfully combined 3 processes into a single tube, thereby allowing ease in handling and an increased detection throughput. The increased pre-PCR yield in MOB allowed efficient, diagnostically sensitive methylation detection.

  12. New approaches to the analysis of complex samples using fluorescence lifetime techniques and organized media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hertz, P.R.

    Fluorescence spectroscopy is a highly sensitive and selective tool for the analysis of complex systems. In order to investigate the efficacy of several steady state and dynamic techniques for the analysis of complex systems, this work focuses on two types of complex, multicomponent samples: petrolatums and coal liquids. It is shown in these studies dynamic, fluorescence lifetime-based measurements provide enhanced discrimination between complex petrolatum samples. Additionally, improved quantitative analysis of multicomponent systems is demonstrated via incorporation of organized media in coal liquid samples. This research provides the first systematic studies of (1) multifrequency phase-resolved fluorescence spectroscopy for dynamic fluorescence spectralmore » fingerprinting of complex samples, and (2) the incorporation of bile salt micellar media to improve accuracy and sensitivity for characterization of complex systems. In the petroleum studies, phase-resolved fluorescence spectroscopy is used to combine spectral and lifetime information through the measurement of phase-resolved fluorescence intensity. The intensity is collected as a function of excitation and emission wavelengths, angular modulation frequency, and detector phase angle. This multidimensional information enhances the ability to distinguish between complex samples with similar spectral characteristics. Examination of the eigenvalues and eigenvectors from factor analysis of phase-resolved and steady state excitation-emission matrices, using chemometric methods of data analysis, confirms that phase-resolved fluorescence techniques offer improved discrimination between complex samples as compared with conventional steady state methods.« less

  13. Coarse kMC-based replica exchange algorithms for the accelerated simulation of protein folding in explicit solvent.

    PubMed

    Peter, Emanuel K; Shea, Joan-Emma; Pivkin, Igor V

    2016-05-14

    In this paper, we present a coarse replica exchange molecular dynamics (REMD) approach, based on kinetic Monte Carlo (kMC). The new development significantly can reduce the amount of replicas and the computational cost needed to enhance sampling in protein simulations. We introduce 2 different methods which primarily differ in the exchange scheme between the parallel ensembles. We apply this approach on folding of 2 different β-stranded peptides: the C-terminal β-hairpin fragment of GB1 and TrpZip4. Additionally, we use the new simulation technique to study the folding of TrpCage, a small fast folding α-helical peptide. Subsequently, we apply the new methodology on conformation changes in signaling of the light-oxygen voltage (LOV) sensitive domain from Avena sativa (AsLOV2). Our results agree well with data reported in the literature. In simulations of dialanine, we compare the statistical sampling of the 2 techniques with conventional REMD and analyze their performance. The new techniques can reduce the computational cost of REMD significantly and can be used in enhanced sampling simulations of biomolecules.

  14. Recent advancements in nanoelectrodes and nanopipettes used in combined scanning electrochemical microscopy techniques.

    PubMed

    Kranz, Christine

    2014-01-21

    In recent years, major developments in scanning electrochemical microscopy (SECM) have significantly broadened the application range of this electroanalytical technique from high-resolution electrochemical imaging via nanoscale probes to large scale mapping using arrays of microelectrodes. A major driving force in advancing the SECM methodology is based on developing more sophisticated probes beyond conventional micro-disc electrodes usually based on noble metals or carbon microwires. This critical review focuses on the design and development of advanced electrochemical probes particularly enabling combinations of SECM with other analytical measurement techniques to provide information beyond exclusively measuring electrochemical sample properties. Consequently, this critical review will focus on recent progress and new developments towards multifunctional imaging.

  15. Imprint-coating synthesis of selective functionalized ordered mesoporous sorbents for separation and sensors

    DOEpatents

    Dai, Sheng; Burleigh, Mark C.; Shin, Yongsoon

    2001-01-01

    The present invention relates generally to mesoporous sorbent materials having high capacity, high selectivity, fast kinetics, and molecular recognition capability. The invention also relates to a process for preparing these mesoporous substrates through molecular imprinting techniques which differ from convention techniques in that a template molecule is bound to one end of bifunctional ligands to form a complex prior to binding of the bifunctional ligands to the substrate. The present invention also relates to methods of using the mesoporous sorbent materials, for example, in the separation of toxic metals from process effluents, paints, and other samples; detection of target molecules, such as amino acids, drugs, herbicides, fertilizers, and TNT, in samples; separation and/or detection of substances using chromatography; imaging agents; sensors; coatings; and composites.

  16. In-vial pyrolysis (PyroVial) with pre- and post-sample treatment combined with different chromatographic techniques.

    PubMed

    Tienpont, Bart; David, Frank; Pereira, Alberto; Sandra, Pat

    2011-11-18

    A new generic pyrolysis unit (PyroVial) is presented. Pyrolysis is carried out in a 2 mL autosampler vial placed in a XYZ robot for automated pyrolysis as well as for pre- and post-pyrolysis treatment of the sample. Analysis of the volatiles is performed by headspace analysis while the semi- and non-volatiles are extracted from the pyrolysate with an organic solvent. The features of the PyroVial are such that all chromatographic techniques can be applied. The pyrolysis unit is discussed in terms of its technical features and its performance is illustrated with applications including conventional pyrolysis, in situ and post-pyrolysis derivatization, reaction pyrolysis and catalytic cracking. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. The Effect of Different Mixing Methods on Working Time, Setting Time, Dimensional Changes and Film Thickness of Mineral Trioxide Aggregate and Calcium-Enriched Mixture.

    PubMed

    Shahi, Shahriar; Ghasemi, Negin; Rahimi, Saeed; Yavari, Hamidreza; Janani, Maryam; Mokhtari, Hadi; Bahari, Mahmood; Rabbani, Parastu

    2015-01-01

    The aim of the present study was to evaluate the effect of different mixing techniques (conventional, amalgamator and ultrasonic mixing) on the physical properties the working time (WT), setting time (ST), dimensional changes (DC) and film thickness (FT)] of calcium-enriched mixture (CEM) cement and mineral trioxide aggregate (MTA). The mentioned physical properties were determined using the ISO 6786:2001 specification. Six samples of each material were prepared for three mixing techniques (totally 36 samples). Data were analyzed using descriptive statistics, two-way ANOVA and Post Hoc Tukey's tests. The level of significance was defined at 0.05. Irrespective of mixing technique, there was no significant difference between the WT and FT of the tested materials. Except for the DC of MTA and the FT of the all materials, other properties were significantly affected with mixing techniques (P<0.05). The ultrasonic technique decreased the ST of MTA and CEM cement and increased the WT of CEM cement (P<0.05). The mixing technique of the materials had no significant effect on the dimensional changes of MTA and the film thickness of both materials.

  18. Evidence of variable bacterial colonization on coloured elastomeric ligatures during orthodontic treatment: An intermodular comparative study.

    PubMed

    Sharma, Ravish; Sharma, Kavita; Sawhney, Rajesh

    2018-03-01

    Besides, other factors, the choice of materials used as orthodontic ligatures could be one of the many tools to counter the effects of microbial adhesion, that culminates into dental ailments. Therefore, we assessed bacterial adhesion on elastomeric ligatures with special reference to coloured elastomeric rings during orthodontic treatment. A split mouth study, involving 240 samples of different elastomeric ligatures from forty orthodontic patients possessing good oral hygiene was carried out. The archwire was ligated to the brackets on both arches with elastomeric rings (superslick, clear transparent , blue and pink) at predetermined quadrants. After six weeks, ligatures from second premolars were removed and processed for bacterial enumeration using standard techniques. Bacterial counts were also determined for stimulated saliva samples taken at 0 and 6 weeks. A statistically significant difference in bacterial counts was obtained amongst different elastomeric modules used. Maximum bacterial counts were found on conventional pigmented elastomeric modules, followed by Superslick module and clear module. More number of bacteria associated with the conventional pink as compared to the conventional blue pigmented modules, however it was not statistically significant. The three bacterial genera Streptococcus Staphylococcus and Aerobic Lactobacilli adhered to elastomeric modules in following predominant pattern i.e. Conventional pink>Conventional Blue>Superslick>Clear. The studies evidenced colour and material dependent bacterial colonization on orthodontic modules and could be an indicator of bacterial biofilm forming potential based on surface chemistries and a clinically efficacious tool to redesign conventional and modified elastomeric rings as orthodontic ligation accessories. Key words: Bacterial colonization, biofilm, coloured elastomers, orthodontic ligatures.

  19. Detection of common diarrhea-causing pathogens in Northern Taiwan by multiplex polymerase chain reaction.

    PubMed

    Huang, Shu-Huan; Lin, Yi-Fang; Tsai, Ming-Han; Yang, Shuan; Liao, Mei-Ling; Chao, Shao-Wen; Hwang, Cheng-Cheng

    2018-06-01

    Conventional methods for identifying gastroenteritis pathogens are time consuming, more likely to result in a false-negative, rely on personnel with diagnostic expertise, and are dependent on the specimen status. Alternatively, molecular diagnostic methods permit the rapid, simultaneous detection of multiple pathogens with high sensitivity and specificity. The present study compared conventional methods with the Luminex xTAG Gastrointestinal Pathogen Panel (xTAG GPP) for the diagnosis of infectious gastroenteritis in northern Taiwan. From July 2015 to April 2016, 217 clinical fecal samples were collected from patients with suspected infectious gastroenteritis. All specimens were tested using conventional diagnostic techniques following physicians' orders as well as with the xTAG GPP. The multiplex polymerase chain reaction (PCR) approach detected significantly more positive samples with bacterial, viral, and/or parasitic infections as compared to conventional analysis (55.8% vs 40.1%, respectively; P < .001). Moreover, multiplex PCR could detect Escherichia coli O157, enterotoxigenic E coli, Shiga-like toxin-producing E coli, Cryptosporidium, and Giardia, which were undetectable by conventional methods. Furthermore, 48 pathogens in 23 patients (10.6%) with coinfections were identified only using the multiplex PCR approach. Of which, 82.6% were from pediatric patients. Because the detection rates using multiplex PCR are higher than conventional methods, and some pediatric pathogens could only be detected by multiplex PCR, this approach may be useful in rapidly diagnosing diarrheal disease in children and facilitating treatment initiation. Further studies are necessary to determine if multiplex PCR improves patient outcomes and reduces costs.

  20. Detection of common diarrhea-causing pathogens in Northern Taiwan by multiplex polymerase chain reaction

    PubMed Central

    Huang, Shu-Huan; Lin, Yi-Fang; Tsai, Ming-Han; Yang, Shuan; Liao, Mei-Ling; Chao, Shao-Wen; Hwang, Cheng-Cheng

    2018-01-01

    Abstract Conventional methods for identifying gastroenteritis pathogens are time consuming, more likely to result in a false-negative, rely on personnel with diagnostic expertise, and are dependent on the specimen status. Alternatively, molecular diagnostic methods permit the rapid, simultaneous detection of multiple pathogens with high sensitivity and specificity. The present study compared conventional methods with the Luminex xTAG Gastrointestinal Pathogen Panel (xTAG GPP) for the diagnosis of infectious gastroenteritis in northern Taiwan. From July 2015 to April 2016, 217 clinical fecal samples were collected from patients with suspected infectious gastroenteritis. All specimens were tested using conventional diagnostic techniques following physicians’ orders as well as with the xTAG GPP. The multiplex polymerase chain reaction (PCR) approach detected significantly more positive samples with bacterial, viral, and/or parasitic infections as compared to conventional analysis (55.8% vs 40.1%, respectively; P < .001). Moreover, multiplex PCR could detect Escherichia coli O157, enterotoxigenic E coli, Shiga-like toxin-producing E coli, Cryptosporidium, and Giardia, which were undetectable by conventional methods. Furthermore, 48 pathogens in 23 patients (10.6%) with coinfections were identified only using the multiplex PCR approach. Of which, 82.6% were from pediatric patients. Because the detection rates using multiplex PCR are higher than conventional methods, and some pediatric pathogens could only be detected by multiplex PCR, this approach may be useful in rapidly diagnosing diarrheal disease in children and facilitating treatment initiation. Further studies are necessary to determine if multiplex PCR improves patient outcomes and reduces costs. PMID:29879060

  1. Use of a Smartphone as a Colorimetric Analyzer in Paper-based Devices for Sensitive and Selective Determination of Mercury in Water Samples.

    PubMed

    Jarujamrus, Purim; Meelapsom, Rattapol; Pencharee, Somkid; Obma, Apinya; Amatatongchai, Maliwan; Ditcharoen, Nadh; Chairam, Sanoe; Tamuang, Suparb

    2018-01-01

    A smartphone application, called CAnal, was developed as a colorimetric analyzer in paper-based devices for sensitive and selective determination of mercury(II) in water samples. Measurement on the double layer of a microfluidic paper-based analytical device (μPAD) fabricated by alkyl ketene dimer (AKD)-inkjet printing technique with special design doped with unmodified silver nanoparticles (AgNPs) onto the detection zones was performed by monitoring the gray intensity in the blue channel of AgNPs, which disintegrated when exposed to mercury(II) on μPAD. Under the optimized conditions, the developed approach showed high sensitivity, low limit of detection (0.003 mg L -1 , 3SD blank/slope of the calibration curve), small sample volume uptake (two times of 2 μL), and short analysis time. The linearity range of this technique ranged from 0.01 to 10 mg L -1 (r 2 = 0.993). Furthermore, practical analysis of various water samples was also demonstrated to have acceptable performance that was in agreement with the data from cold vapor atomic absorption spectrophotometry (CV-AAS), a conventional method. The proposed technique allows for a rapid, simple (instant report of the final mercury(II) concentration in water samples via smartphone display), sensitive, selective, and on-site analysis with high sample throughput (48 samples h -1 , n = 3) of trace mercury(II) in water samples, which is suitable for end users who are unskilled in analyzing mercury(II) in water samples.

  2. Conceptual models in exploration geochemistry-The Basin and Range Province of the Western United States and Northern Mexico

    USGS Publications Warehouse

    Lovering, T.G.; McCarthy, J.H.

    1978-01-01

    This summary of geochemical exploration in the Basin and Range Province is another in the series of reviews of geochemical-exploration applications covering a large region; this series began in 1975 with a summary for the Canadian Cordillera and Canadian Shield, and was followed in 1976 by a similar summary for Scandinavia (Norden). Rather than adhering strictly to the type of conceptual models applied in those papers, we have made use of generalized landscape geochemistry models related to the nature of concealment of ore deposits. This study is part of a continuing effort to examine and evaluate geochemical-exploration practices in different areas of the world. Twenty case histories of the application of geochemical exploration in both district and regional settings illustrate recent developments in techniques and approaches. Along with other published reports these case histories, exemplifying generalized models of concealed deposits, provide data used to evaluate geochemical-exploration programs and specific sample media. Because blind deposits are increasingly sought in the Basin and Range Province, the use of new sample media or anomaly-enhancement techniques is a necessity. Analysis of vapors or gases emanating from blind deposits is a promising new technique. Certain fractions of stream sediments show anomalies that are weak or not detected in conventional minus 80-mesh fractions. Multi-element analysis of mineralized bedrock may show zoning patterns that indicate depth or direction of ore. Examples of the application of these and other, more conventional methods are indicated in the case histories. The final section of this paper contains a brief evaluation of the applications of all types of sample media to geochemical exploration in the arid environment of the Basin and Range Province. ?? 1978.

  3. Investigation of Legionella Contamination in Bath Water Samples by Culture, Amoebic Co-Culture, and Real-Time Quantitative PCR Methods.

    PubMed

    Edagawa, Akiko; Kimura, Akio; Kawabuchi-Kurata, Takako; Adachi, Shinichi; Furuhata, Katsunori; Miyamoto, Hiroshi

    2015-10-19

    We investigated Legionella contamination in bath water samples, collected from 68 bathing facilities in Japan, by culture, culture with amoebic co-culture, real-time quantitative PCR (qPCR), and real-time qPCR with amoebic co-culture. Using the conventional culture method, Legionella pneumophila was detected in 11 samples (11/68, 16.2%). Contrary to our expectation, the culture method with the amoebic co-culture technique did not increase the detection rate of Legionella (4/68, 5.9%). In contrast, a combination of the amoebic co-culture technique followed by qPCR successfully increased the detection rate (57/68, 83.8%) compared with real-time qPCR alone (46/68, 67.6%). Using real-time qPCR after culture with amoebic co-culture, more than 10-fold higher bacterial numbers were observed in 30 samples (30/68, 44.1%) compared with the same samples without co-culture. On the other hand, higher bacterial numbers were not observed after propagation by amoebae in 32 samples (32/68, 47.1%). Legionella was not detected in the remaining six samples (6/68, 8.8%), irrespective of the method. These results suggest that application of the amoebic co-culture technique prior to real-time qPCR may be useful for the sensitive detection of Legionella from bath water samples. Furthermore, a combination of amoebic co-culture and real-time qPCR might be useful to detect viable and virulent Legionella because their ability to invade and multiply within free-living amoebae is considered to correlate with their pathogenicity for humans. This is the first report evaluating the efficacy of the amoebic co-culture technique for detecting Legionella in bath water samples.

  4. Investigation of Legionella Contamination in Bath Water Samples by Culture, Amoebic Co-Culture, and Real-Time Quantitative PCR Methods

    PubMed Central

    Edagawa, Akiko; Kimura, Akio; Kawabuchi-Kurata, Takako; Adachi, Shinichi; Furuhata, Katsunori; Miyamoto, Hiroshi

    2015-01-01

    We investigated Legionella contamination in bath water samples, collected from 68 bathing facilities in Japan, by culture, culture with amoebic co-culture, real-time quantitative PCR (qPCR), and real-time qPCR with amoebic co-culture. Using the conventional culture method, Legionella pneumophila was detected in 11 samples (11/68, 16.2%). Contrary to our expectation, the culture method with the amoebic co-culture technique did not increase the detection rate of Legionella (4/68, 5.9%). In contrast, a combination of the amoebic co-culture technique followed by qPCR successfully increased the detection rate (57/68, 83.8%) compared with real-time qPCR alone (46/68, 67.6%). Using real-time qPCR after culture with amoebic co-culture, more than 10-fold higher bacterial numbers were observed in 30 samples (30/68, 44.1%) compared with the same samples without co-culture. On the other hand, higher bacterial numbers were not observed after propagation by amoebae in 32 samples (32/68, 47.1%). Legionella was not detected in the remaining six samples (6/68, 8.8%), irrespective of the method. These results suggest that application of the amoebic co-culture technique prior to real-time qPCR may be useful for the sensitive detection of Legionella from bath water samples. Furthermore, a combination of amoebic co-culture and real-time qPCR might be useful to detect viable and virulent Legionella because their ability to invade and multiply within free-living amoebae is considered to correlate with their pathogenicity for humans. This is the first report evaluating the efficacy of the amoebic co-culture technique for detecting Legionella in bath water samples. PMID:26492259

  5. Tube and column agglutination technology for autocontrol testing.

    PubMed

    Courtney, J E; Vincent, J L; Indrikovs, A J

    2001-01-01

    The incidence of positive autocontrol test results with column agglutination technology is a concern. This study investigates the incidence and significance of positive autocontrols in the ID Micro Typing System (gel) and the Gamma ReACT (ReACT). The study encompassed a total of 1021 randomly selected samples from patients and 95 samples from donors collected during 1 month. The autocontrol testing was carried out according to the manufacturer's instructions for the column agglutination tests. The tube method was carried out using low-ionic-strength solution (LISS). The direct antiglobulin test (DAT) was performed using the tube method, and further investigated with elution studies if warranted. Seventy-nine patient's samples (7.74%) had a positive autocontrol: the gel test, 72 (91.13%); ReACT, 21 (26.58%); and the tube method, 27 (34.18%). Of the 79 positive autocontrols, 44 samples had a negative DAT. Of the samples with positive DAT results, only one possessed a clinically significant antibody, anti-D. Moreover, the same sample also tested positive in all three methods. Column agglutination techniques have increased sensitivity for a positive autocontrol beyond the conventional tube method. However, ReACT and gel tests differ significantly in their frequency of positives. Investigation of the significance of a positive autocontrol in column agglutination technology when the conventional tube method is also positive is suggested.

  6. A versatile setup using femtosecond adaptive spectroscopic techniques for coherent anti-Stokes Raman scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, Yujie, E-mail: styojm@physics.tamu.edu; Voronine, Dmitri V.; Sokolov, Alexei V.

    2015-08-15

    We report a versatile setup based on the femtosecond adaptive spectroscopic techniques for coherent anti-Stokes Raman scattering. The setup uses a femtosecond Ti:Sapphire oscillator source and a folded 4f pulse shaper, in which the pulse shaping is carried out through conventional optical elements and does not require a spatial light modulator. Our setup is simple in alignment, and can be easily switched between the collinear single-beam and the noncollinear two-beam configurations. We demonstrate the capability for investigating both transparent and highly scattering samples by detecting transmitted and reflected signals, respectively.

  7. Matching technique yields optimum LNA performance. [Low Noise Amplifiers

    NASA Technical Reports Server (NTRS)

    Sifri, J. D.

    1986-01-01

    The present article is concerned with a case in which an optimum noise figure and unconditional stability have been designed into a 2.385-GHz low-noise preamplifier via an unusual method for matching the input with a suspended line. The results obtained with several conventional line-matching techniques were not satisfactory. Attention is given to the minimization of thermal noise, the design procedure, requirements for a high-impedance line, a sampling of four matching networks, the noise figure of the single-line matching network as a function of frequency, and the approaches used to achieve unconditional stability.

  8. Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes

    PubMed Central

    2014-01-01

    Background The purpose of this study was to compare two impression techniques from the perspective of patient preferences and treatment comfort. Methods Twenty-four (12 male, 12 female) subjects who had no previous experience with either conventional or digital impression participated in this study. Conventional impressions of maxillary and mandibular dental arches were taken with a polyether impression material (Impregum, 3 M ESPE), and bite registrations were made with polysiloxane bite registration material (Futar D, Kettenbach). Two weeks later, digital impressions and bite scans were performed using an intra-oral scanner (CEREC Omnicam, Sirona). Immediately after the impressions were made, the subjects’ attitudes, preferences and perceptions towards impression techniques were evaluated using a standardized questionnaire. The perceived source of stress was evaluated using the State-Trait Anxiety Scale. Processing steps of the impression techniques (tray selection, working time etc.) were recorded in seconds. Statistical analyses were performed with the Wilcoxon Rank test, and p < 0.05 was considered significant. Results There were significant differences among the groups (p < 0.05) in terms of total working time and processing steps. Patients stated that digital impressions were more comfortable than conventional techniques. Conclusions Digital impressions resulted in a more time-efficient technique than conventional impressions. Patients preferred the digital impression technique rather than conventional techniques. PMID:24479892

  9. An evaluation of student and clinician perception of digital and conventional implant impressions.

    PubMed

    Lee, Sang J; Macarthur, Robert X; Gallucci, German O

    2013-11-01

    The accuracy and efficiency of digital implant impressions should match conventional impressions. Comparisons should be made with clinically relevant data. The purpose of this study was to evaluate the difficulty level and operator's perception between dental students and experienced clinicians when making digital and conventional implant impressions. Thirty experienced dental professionals and 30 second-year dental students made conventional and digital impressions of a single implant model. A visual analog scale (VAS) and multiple-choice questionnaires were used to assess the participant's perception of difficulty, preference, and effectiveness. Wilcoxon signed-rank test within the groups and Wilcoxon rank-sum test between the groups were used for statistical analysis (α=.05). On a 0 to 100 VAS, the student group scored a mean difficulty level of 43.1 (±18.5) for the conventional impression technique and 30.6 (±17.6) for the digital impression technique (P=.006). The clinician group scored a mean (standard deviation) difficulty level of 30.9 (±19.6) for conventional impressions and 36.5 (±20.6) for digital impressions (P=.280). Comparison between groups showed a mean difficulty level with the conventional impression technique significantly higher in the student group (P=.030). The digital impression was not significantly different between the groups (P=.228). Sixty percent of the students preferred the digital impression and 7% the conventional impression; 33% expressed no preference. In the clinician group, 33% preferred the digital impression and 37% the conventional impression; 30% had no preference. Seventy-seven percent of the student group felt most effective with digital impressions, 10% with conventional impressions, and 13% with either technique, whereas 40% of the clinician group chose the digital impression as the most effective technique, 53% the conventional impression, and 7% either technique. The conventional impression was more difficult to perform for the student group than the clinician group; however, the difficulty level of the digital impression was the same in both groups. It was also determined that the student group preferred the digital impression as the most efficient impression technique, and the clinician group had an even distribution in the choice of preferred and efficient impression techniques. Copyright © 2013 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  10. Hexagonal undersampling for faster MRI near metallic implants.

    PubMed

    Sveinsson, Bragi; Worters, Pauline W; Gold, Garry E; Hargreaves, Brian A

    2015-02-01

    Slice encoding for metal artifact correction acquires a three-dimensional image of each excited slice with view-angle tilting to reduce slice and readout direction artifacts respectively, but requires additional imaging time. The purpose of this study was to provide a technique for faster imaging around metallic implants by undersampling k-space. Assuming that areas of slice distortion are localized, hexagonal sampling can reduce imaging time by 50% compared with conventional scans. This work demonstrates this technique by comparisons of fully sampled images with undersampled images, either from simulations from fully acquired data or from data actually undersampled during acquisition, in patients and phantoms. Hexagonal sampling is also shown to be compatible with parallel imaging and partial Fourier acquisitions. Image quality was evaluated using a structural similarity (SSIM) index. Images acquired with hexagonal undersampling had no visible difference in artifact suppression from fully sampled images. The SSIM index indicated high similarity to fully sampled images in all cases. The study demonstrates the ability to reduce scan time by undersampling without compromising image quality. © 2014 Wiley Periodicals, Inc.

  11. Development of a rapid screening technique for organochlorine pesticides using solvent microextraction (SME) and fast gas chromatography (GC).

    PubMed

    de Jager, L S; Andrews, A R

    2000-11-01

    A novel, fast screening method for organochlorine pesticides (OCPs) in water samples has been developed. Total analysis time was less than 9 min, allowing 11 samples to be screened per hour. The relatively new technique of solvent microextraction (SME) was used to extract and preconcentrate the pesticides into a single drop of hexane. The use of a conventional carbon dioxide cryotrap was investigated for introduction of the extract onto a micro-bore (0.1 mm) capillary column for fast GC analysis. A pulsed-discharge electron capture detector was used which yielded selective and sensitive measurement of the pesticide peaks. Fast GC conditions were optimised and tested with the previously developed SME procedure. Calibration curves yielded good linearity and concentrations down to 0.25 ng mL-1 were detectable with RSD values ranging from 12.0 to 28% and LOD for most OCPs at 0.25 ng mL-1. Spiked river water samples were tested and using the developed screen we were able to differentiate between spiked samples and samples containing no OCPs.

  12. Ferrous sulfate based low temperature synthesis and magnetic properties of nickel ferrite nanostructures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tejabhiram, Y., E-mail: tejabhiram@gmail.com; Pradeep, R.; Helen, A.T.

    2014-12-15

    Highlights: • Novel low temperature synthesis of nickel ferrite nanoparticles. • Comparison with two conventional synthesis techniques including hydrothermal method. • XRD results confirm the formation of crystalline nickel ferrites at 110 °C. • Superparamagnetic particles with applications in drug delivery and hyperthermia. • Magnetic properties superior to conventional methods found in new process. - Abstract: We report a simple, low temperature and surfactant free co-precipitation method for the preparation of nickel ferrite nanostructures using ferrous sulfate as the iron precursor. The products obtained from this method were compared for their physical properties with nickel ferrites produced through conventional co-precipitationmore » and hydrothermal methods which used ferric nitrate as the iron precursor. X-ray diffraction analysis confirmed the synthesis of single phase inverse spinel nanocrystalline nickel ferrites at temperature as low as 110 °C in the low temperature method. Electron microscopy analysis on the samples revealed the formation of nearly spherical nanostructures in the size range of 20–30 nm which are comparable to other conventional methods. Vibrating sample magnetometer measurements showed the formation of superparamagnetic particles with high magnetic saturation 41.3 emu/g which corresponds well with conventional synthesis methods. The spontaneous synthesis of the nickel ferrite nanoparticles by the low temperature synthesis method was attributed to the presence of 0.808 kJ mol{sup −1} of excess Gibbs free energy due to ferrous sulfate precursor.« less

  13. Quantitative ultrasonic testing of acoustically anisotropic materials with verification on austenitic and dissimilar weld joints

    NASA Astrophysics Data System (ADS)

    Boller, C.; Pudovikov, S.; Bulavinov, A.

    2012-05-01

    Austenitic stainless steel materials are widely used in a variety of industry sectors. In particular, the material is qualified to meet the design criteria of high quality in safety related applications. For example, the primary loop of the most of the nuclear power plants in the world, due to high durability and corrosion resistance, is made of this material. Certain operating conditions may cause a range of changes in the integrity of the component, and therefore require nondestructive testing at reasonable intervals. These in-service inspections are often performed using ultrasonic techniques, in particular when cracking is of specific concern. However, the coarse, dendritic grain structure of the weld material, formed during the welding process, is extreme and unpredictably anisotropic. Such structure is no longer direction-independent to the ultrasonic wave propagation; therefore, the ultrasonic beam deflects and redirects and the wave front becomes distorted. Thus, the use of conventional ultrasonic testing techniques using fixed beam angles is very limited and the application of ultrasonic Phased Array techniques becomes desirable. The "Sampling Phased Array" technique, invented and developed by Fraunhofer IZFP, allows the acquisition of time signals (A-scans) for each individual transducer element of the array along with fast image reconstruction techniques based on synthetic focusing algorithms. The reconstruction considers the sound propagation from each image pixel to the individual sensor element. For anisotropic media, where the sound beam is deflected and the sound path is not known a-priori, a novel phase adjustment technique called "Reverse Phase Matching" is implemented. By taking into account the anisotropy and inhomogeneity of the weld structure, a ray tracing algorithm for modeling the acoustic wave propagation and calculating the sound propagation time is applied. This technique can be utilized for 2D and 3D real time image reconstruction. The "Gradient Constant Descent Method" (GECDM), an iterative algorithm, is implemented, which is essential for examination of inhomogeneous anisotropic media having unknown properties (elastic constants). The Sampling Phased Array technique with Reverse Phase Matching extended by GECDM-technique determines unknown elastic constants and provides reliable and efficient quantitative flaw detection in the austenitic welds. The validation of ray-tracing algorithm and GECDM-method is performed by number of experiments on test specimens with artificial as well as natural material flaws. A mechanized system for ultrasonic testing of stainless steel and dissimilar welds is developed. The system works on both conventional and Sampling Phased Array techniques. The new frontend ultrasonic unit with optical data link allows the 3D visualization of the inspection results in real time.

  14. Computer-Assisted Total Knee Arthroplasty: Is There a Difference Between Image-Based and Imageless Techniques?

    PubMed

    Tabatabaee, Reza M; Rasouli, Mohammad R; Maltenfort, Mitchell G; Fuino, Robert; Restrepo, Camilo; Oliashirazi, Ali

    2018-04-01

    Image-based and imageless computer-assisted total knee arthroplasty (CATKA) has become increasingly popular. This study aims to compare outcomes, including perioperative complications and transfusion rate, between CATKA and conventional total knee arthroplasty (TKA), as well as between image-based and imageless CATKA. Using the 9th revision of the International Classification of Diseases codes, we queried the Nationwide Inpatient Sample database from 2005 to 2011 to identify unilateral conventional TKA, image-based, and imageless CATKAs as well as in-hospital complications and transfusion rates. A total of 787,809 conventional TKAs and 13,246 CATKAs (1055 image-based and 12,191 imageless) were identified. The rate of CATKA increased 23.13% per year from 2005 to 2011. Transfusion rates in conventional TKA and CATKA cases were 11.73% and 8.20% respectively (P < .001) and 6.92% in image-based vs 8.27% in imageless (P = .023). Perioperative complications occurred in 4.50%, 3.47%, and 3.41% of cases after conventional, imageless, and imaged-based CATKAs, respectively. Using multivariate analysis, perioperative complications were significantly higher in conventional TKA compared to CATKA (odds ratio = 1.17, 95% confidence interval 1.03-1.33, P = .01). There was no significant difference between imageless and image-based CATKA (P = .34). Length of hospital stay and hospital charges were not significantly different between groups (P > .05). CATKA has low complication rates and may improve patient outcomes after TKA. CATKA, especially the image-based technique, may reduce in-hospital complications and transfusion without increasing hospital charges and length of hospital stay significantly. Large prospective studies with long follow-up are required to verify potential benefits of CATKA. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Field assessment of alternative bed-load transport estimators

    USGS Publications Warehouse

    Gaeuman, G.; Jacobson, R.B.

    2007-01-01

    Measurement of near-bed sediment velocities with acoustic Doppler current profilers (ADCPs) is an emerging approach for quantifying bed-load sediment fluxes in rivers. Previous investigations of the technique have relied on conventional physical bed-load sampling to provide reference transport information with which to validate the ADCP measurements. However, physical samples are subject to substantial errors, especially under field conditions in which surrogate methods are most needed. Comparisons between ADCP bed velocity measurements with bed-load transport rates estimated from bed-form migration rates in the lower Missouri River show a strong correlation between the two surrogate measures over a wide range of mild to moderately intense sediment transporting conditions. The correlation between the ADCP measurements and physical bed-load samples is comparatively poor, suggesting that physical bed-load sampling is ineffective for ground-truthing alternative techniques in large sand-bed rivers. Bed velocities measured in this study became more variable with increasing bed-form wavelength at higher shear stresses. Under these conditions, bed-form dimensions greatly exceed the region of the bed ensonified by the ADCP, and the magnitude of the acoustic measurements depends on instrument location with respect to bed-form crests and troughs. Alternative algorithms for estimating bed-load transport from paired longitudinal profiles of bed topography were evaluated. An algorithm based on the routing of local erosion and deposition volumes that eliminates the need to identify individual bed forms was found to give results similar to those of more conventional dune-tracking methods. This method is particularly useful in cases where complex bed-form morphology makes delineation of individual bed forms difficult. ?? 2007 ASCE.

  16. Optimising a modified free-space permittivity characterisation method for civil engineering applications

    NASA Astrophysics Data System (ADS)

    Muller, Wayne; Scheuermann, Alexander

    2016-04-01

    Measuring the electrical permittivity of civil engineering materials is important for a range of ground penetrating radar (GPR) and pavement moisture measurement applications. Compacted unbound granular (UBG) pavement materials present a number of preparation and measurement challenges using conventional characterisation techniques. As an alternative to these methods, a modified free-space (MFS) characterisation approach has previously been investigated. This paper describes recent work to optimise and validate the MFS technique. The research included finite difference time domain (FDTD) modelling to better understand the nature of wave propagation within material samples and the test apparatus. This research led to improvements in the test approach and optimisation of sample sizes. The influence of antenna spacing and sample thickness on the permittivity results was investigated by a series of experiments separating antennas and measuring samples of nylon and water. Permittivity measurements of samples of nylon and water approximately 100 mm and 170 mm thick were also compared, showing consistent results. These measurements also agreed well with surface probe measurements of the nylon sample and literature values for water. The results indicate permittivity estimates of acceptable accuracy can be obtained using the proposed approach, apparatus and sample sizes.

  17. Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques

    PubMed Central

    Jeon, Young-Chan; Jeong, Chang-Mo

    2017-01-01

    PURPOSE The purpose of this study was to compare the fit of cast gold crowns fabricated from the conventional and the digital impression technique. MATERIALS AND METHODS Artificial tooth in a master model and abutment teeth in ten patients were restored with cast gold crowns fabricated from the digital and the conventional impression technique. The forty silicone replicas were cut in three sections; each section was evaluated in nine points. The measurement was carried out by using a measuring microscope and I-Soultion. Data from the silicone replica were analyzed and all tests were performed with α-level of 0.05. RESULTS 1. The average gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. 2. In marginal and internal axial gap of cast gold crowns, no statistical differences were found between the two impression techniques. 3. The internal occlusal gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. CONCLUSION Both prostheses presented clinically acceptable results with comparing the fit. The prostheses fabricated from the digital impression technique showed more gaps, in respect of occlusal surface. PMID:28243386

  18. Thresher: an improved algorithm for peak height thresholding of microbial community profiles.

    PubMed

    Starke, Verena; Steele, Andrew

    2014-11-15

    This article presents Thresher, an improved technique for finding peak height thresholds for automated rRNA intergenic spacer analysis (ARISA) profiles. We argue that thresholds must be sample dependent, taking community richness into account. In most previous fragment analyses, a common threshold is applied to all samples simultaneously, ignoring richness variations among samples and thereby compromising cross-sample comparison. Our technique solves this problem, and at the same time provides a robust method for outlier rejection, selecting for removal any replicate pairs that are not valid replicates. Thresholds are calculated individually for each replicate in a pair, and separately for each sample. The thresholds are selected to be the ones that minimize the dissimilarity between the replicates after thresholding. If a choice of threshold results in the two replicates in a pair failing a quantitative test of similarity, either that threshold or that sample must be rejected. We compare thresholded ARISA results with sequencing results, and demonstrate that the Thresher algorithm outperforms conventional thresholding techniques. The software is implemented in R, and the code is available at http://verenastarke.wordpress.com or by contacting the author. vstarke@ciw.edu or http://verenastarke.wordpress.com Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  19. A rapid method for the sampling of atmospheric water vapour for isotopic analysis.

    PubMed

    Peters, Leon I; Yakir, Dan

    2010-01-01

    Analysis of the stable isotopic composition of atmospheric moisture is widely applied in the environmental sciences. Traditional methods for obtaining isotopic compositional data from ambient moisture have required complicated sampling procedures, expensive and sophisticated distillation lines, hazardous consumables, and lengthy treatments prior to analysis. Newer laser-based techniques are expensive and usually not suitable for large-scale field campaigns, especially in cases where access to mains power is not feasible or high spatial coverage is required. Here we outline the construction and usage of a novel vapour-sampling system based on a battery-operated Stirling cycle cooler, which is simple to operate, does not require any consumables, or post-collection distillation, and is light-weight and highly portable. We demonstrate the ability of this system to reproduce delta(18)O isotopic compositions of ambient water vapour, with samples taken simultaneously by a traditional cryogenic collection technique. Samples were collected over 1 h directly into autosampler vials and were analysed by mass spectrometry after pyrolysis of 1 microL aliquots to CO. This yielded an average error of < +/-0.5 per thousand, approximately equal to the signal-to-noise ratio of traditional approaches. This new system provides a rapid and reliable alternative to conventional cryogenic techniques, particularly in cases requiring high sample throughput or where access to distillation lines, slurry maintenance or mains power is not feasible. Copyright 2009 John Wiley & Sons, Ltd.

  20. Colorization-Based RGB-White Color Interpolation using Color Filter Array with Randomly Sampled Pattern

    PubMed Central

    Oh, Paul; Lee, Sukho; Kang, Moon Gi

    2017-01-01

    Recently, several RGB-White (RGBW) color filter arrays (CFAs) have been proposed, which have extra white (W) pixels in the filter array that are highly sensitive. Due to the high sensitivity, the W pixels have better SNR (Signal to Noise Ratio) characteristics than other color pixels in the filter array, especially, in low light conditions. However, most of the RGBW CFAs are designed so that the acquired RGBW pattern image can be converted into the conventional Bayer pattern image, which is then again converted into the final color image by using conventional demosaicing methods, i.e., color interpolation techniques. In this paper, we propose a new RGBW color filter array based on a totally different color interpolation technique, the colorization algorithm. The colorization algorithm was initially proposed for colorizing a gray image into a color image using a small number of color seeds. Here, we adopt this algorithm as a color interpolation technique, so that the RGBW color filter array can be designed with a very large number of W pixels to make the most of the highly sensitive characteristics of the W channel. The resulting RGBW color filter array has a pattern with a large proportion of W pixels, while the small-numbered RGB pixels are randomly distributed over the array. The colorization algorithm makes it possible to reconstruct the colors from such a small number of RGB values. Due to the large proportion of W pixels, the reconstructed color image has a high SNR value, especially higher than those of conventional CFAs in low light condition. Experimental results show that many important information which are not perceived in color images reconstructed with conventional CFAs are perceived in the images reconstructed with the proposed method. PMID:28657602

  1. Colorization-Based RGB-White Color Interpolation using Color Filter Array with Randomly Sampled Pattern.

    PubMed

    Oh, Paul; Lee, Sukho; Kang, Moon Gi

    2017-06-28

    Recently, several RGB-White (RGBW) color filter arrays (CFAs) have been proposed, which have extra white (W) pixels in the filter array that are highly sensitive. Due to the high sensitivity, the W pixels have better SNR (Signal to Noise Ratio) characteristics than other color pixels in the filter array, especially, in low light conditions. However, most of the RGBW CFAs are designed so that the acquired RGBW pattern image can be converted into the conventional Bayer pattern image, which is then again converted into the final color image by using conventional demosaicing methods, i.e., color interpolation techniques. In this paper, we propose a new RGBW color filter array based on a totally different color interpolation technique, the colorization algorithm. The colorization algorithm was initially proposed for colorizing a gray image into a color image using a small number of color seeds. Here, we adopt this algorithm as a color interpolation technique, so that the RGBW color filter array can be designed with a very large number of W pixels to make the most of the highly sensitive characteristics of the W channel. The resulting RGBW color filter array has a pattern with a large proportion of W pixels, while the small-numbered RGB pixels are randomly distributed over the array. The colorization algorithm makes it possible to reconstruct the colors from such a small number of RGB values. Due to the large proportion of W pixels, the reconstructed color image has a high SNR value, especially higher than those of conventional CFAs in low light condition. Experimental results show that many important information which are not perceived in color images reconstructed with conventional CFAs are perceived in the images reconstructed with the proposed method.

  2. Agreement between gastrointestinal panel testing and standard microbiology methods for detecting pathogens in suspected infectious gastroenteritis: Test evaluation and meta-analysis in the absence of a reference standard.

    PubMed

    Freeman, Karoline; Tsertsvadze, Alexander; Taylor-Phillips, Sian; McCarthy, Noel; Mistry, Hema; Manuel, Rohini; Mason, James

    2017-01-01

    Multiplex gastrointestinal pathogen panel (GPP) tests simultaneously identify bacterial, viral and parasitic pathogens from the stool samples of patients with suspected infectious gastroenteritis presenting in hospital or the community. We undertook a systematic review to compare the accuracy of GPP tests with standard microbiology techniques. Searches in Medline, Embase, Web of Science and the Cochrane library were undertaken from inception to January 2016. Eligible studies compared GPP tests with standard microbiology techniques in patients with suspected gastroenteritis. Quality assessment of included studies used tailored QUADAS-2. In the absence of a reference standard we analysed test performance taking GPP tests and standard microbiology techniques in turn as the benchmark test, using random effects meta-analysis of proportions. No study provided an adequate reference standard with which to compare the test accuracy of GPP and conventional tests. Ten studies informed a meta-analysis of positive and negative agreement. Positive agreement across all pathogens was 0.93 (95% CI 0.90 to 0.96) when conventional methods were the benchmark and 0.68 (95% CI: 0.58 to 0.77) when GPP provided the benchmark. Negative agreement was high in both instances due to the high proportion of negative cases. GPP testing produced a greater number of pathogen-positive findings than conventional testing. It is unclear whether these additional 'positives' are clinically important. GPP testing has the potential to simplify testing and accelerate reporting when compared to conventional microbiology methods. However the impact of GPP testing upon the management, treatment and outcome of patients is poorly understood and further studies are needed to evaluate the health economic impact of GPP testing compared with standard methods. The review protocol is registered with PROSPERO as CRD42016033320.

  3. Simultaneous and individual quantitative estimation of Salmonella, Shigella and Listeria monocytogenes on inoculated Roma tomatoes (Lycopersicon esculentum var. Pyriforme) and Serrano peppers (Capsicum annuum) using an MPN technique.

    PubMed

    Cabrera-Díaz, E; Martínez-Chávez, L; Sánchez-Camarena, J; Muñiz-Flores, J A; Castillo, A; Gutiérrez-González, P; Arvizu-Medrano, S M; González-Aguilar, D G; Martínez-Gonzáles, N E

    2018-08-01

    Simultaneous and individual enumeration of Salmonella, Shigella and Listeria monocytogenes was compared on inoculated Roma tomatoes and Serrano peppers using an Most Probable Number (MPN) technique. Samples consisting of tomatoes (4 units) or peppers (8 units) were individually inoculated with a cocktail of three strains of Salmonella, Shigella or L. monocytogenes, or by simultaneous inoculation of three strains of each pathogen, at low (1.2-1.7 log CFU/sample) and high (2.2-2.7 log CFU/sample) inocula. Samples were analyzed by an MPN technique using universal pre-enrichment (UP) broth at 35 °C for 24 ± 2 h. The UP tubes from each MPN series were transferred to enrichment and plating media following adequate conventional methods for isolating each pathogen. Data were analyzed using multifactorial analysis of variance (p < 0.05) and LSD multiple rang test. There were differences (p < 0.05) in recovery of simultaneous and individual bacteria inoculated (individual > simultaneous), type of bacteria (Salmonella > Shigella and L. monocytogenes), type of sample (UP broth > pepper and tomato), and inoculum level (high > low). The MPN technique was effective for Salmonella on both commodities. Shigella counts were higher on tomatoes compared to peppers, (p < 0.05), and for L. monocytogenes on peppers (p < 0.05). Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Detection of hyphomycetes in the upper respiratory tract of patients with cystic fibrosis.

    PubMed

    Horré, R; Marklein, G; Siekmeier, R; Reiffert, S-M

    2011-11-01

    The respiratory tract of cystic fibrosis patients is colonised by bacteria and fungi. Although colonisation by slow growing fungi such as Pseudallescheria, Scedosporium and Exophiala species has been studied previously, the colonisation rate differs from study to study. Infections caused by these fungi have been recognised, especially after lung transplants. Monitoring of respiratory tract colonisation in cystic fibrosis patients includes the use of several semi-selective culture media to detect bacteria such as Pseudomonas aeruginosa and Burkholderia cepacia as well as Candida albicans. It is relevant to study whether conventional methods are sufficient for the detection of slow growing hyphomycetes or if additional semi-selective culture media should be used. In total, 589 respiratory specimens from cystic fibrosis patients were examined for the presence of slow growing hyphomycetes. For 439 samples from 81 patients, in addition to conventional methods, erythritol-chloramphenicol agar was used for the selective isolation of Exophiala dermatitidis and paraffin-covered liquid Sabouraud media for the detection of phaeohyphomycetes. For 150 subsequent samples from 42 patients, SceSel+ agar was used for selective isolation of Pseudallescheria and Scedosporium species,and brain-heart infusion bouillon containing a wooden stick for hyphomycete detection. Selective isolation techniques were superior in detecting non-Aspergillus hyphomycetes compared with conventional methods. Although liquid media detected fewer strains of Exophiala, Pseudallescheria and Scedosporium species, additional hyphomycete species not detected by other methods were isolated. Current conventional methods are insufficient to detect non-Aspergillus hyphomycetes, especially Exophiala, Pseudallescheria and Scedosporium species, in sputum samples of cystic fibrosis patients. © 2010 Blackwell Verlag GmbH.

  5. Pressurized capillary electrochromatographic analysis of water-soluble vitamins by combining with on-line concentration technique.

    PubMed

    Jia, Li; Liu, Yaling; Du, Yanyan; Xing, Da

    2007-06-22

    A pressurized capillary electrochromatography (pCEC) system was developed for the separation of water-soluble vitamins, in which UV absorbance was used as the detection method and a monolithic silica-ODS column as the separation column. The parameters (type and content of organic solvent in the mobile phase, type and concentration of electrolyte, pH of the electrolyte buffer, applied voltage and flow rate) affecting the separation resolution were evaluated. The combination of two on-line concentration techniques, namely, solvent gradient zone sharpening effect and field-enhanced sample stacking, was utilized to improve detection sensitivity, which proved to be beneficial to enhance the detection sensitivity by enabling the injection of large volumes of samples. Coupling electrokinetic injection with the on-line concentration techniques was much more beneficial for the concentration of positively charged vitamins. Comparing with the conventional injection mode, the enhancement in the detection sensitivities of water-soluble vitamins using the on-line concentration technique is in the range of 3 to 35-fold. The developed pCEC method was applied to evaluate water-soluble vitamins in corns.

  6. The Use of Different Irrigation Techniques to Decrease Bacterial Loads in Healthy and Diabetic Patients with Asymptomatic Apical Periodontitis.

    PubMed

    Ghoneim, Mai; Saber, Shehab ElDin; El-Badry, Tarek; Obeid, Maram; Hassib, Nehal

    2016-12-15

    Diabetes mellitus is a multisystem disease which weakens the human's immunity. Subsequently, it worsens the sequelae of apical periodontitis by raising a fierce bacterial trait due to the impaired host response. This study aimed to estimate bacterial reduction after using different irrigation techniques in systemically healthy and diabetic patients with asymptomatic apical periodontitis. Enterococcus faecalis , Peptostreptococcus micros , and Fusobacterium necleatum bacteria were chosen, as they are the most common and prevailing strains found in periodontitis. Bacterial samples were retrieved from necrotic root canals of systemically healthy and diabetic patients, before and after endodontic cleaning and shaping by using two different irrigation techniques; the conventional one and the EndoVac system. Quantitive polymerase chain reaction (qPCR) was utilised to detect the reduction in the bacterial count. The EndoVac irrigation system was effective in reducing bacteria, especially Peptostreptococcus micros in the diabetic group when compared to conventional irrigation technique with a statistically significant difference. The EndoVac can be considered as a promising tool in combination with irrigant solution to defeat the bacterial colonies living in the root canal system. Additional studies ought to be done to improve the means of bacterial clearance mainly in immune-compromised individuals.

  7. The Use of Different Irrigation Techniques to Decrease Bacterial Loads in Healthy and Diabetic Patients with Asymptomatic Apical Periodontitis

    PubMed Central

    Ghoneim, Mai; Saber, Shehab ElDin; El-Badry, Tarek; Obeid, Maram; Hassib, Nehal

    2016-01-01

    BACKGROUND: Diabetes mellitus is a multisystem disease which weakens the human’s immunity. Subsequently, it worsens the sequelae of apical periodontitis by raising a fierce bacterial trait due to the impaired host response. AIM: This study aimed to estimate bacterial reduction after using different irrigation techniques in systemically healthy and diabetic patients with asymptomatic apical periodontitis. MATERIAL AND METHODS: Enterococcus faecalis, Peptostreptococcus micros, and Fusobacterium necleatum bacteria were chosen, as they are the most common and prevailing strains found in periodontitis. Bacterial samples were retrieved from necrotic root canals of systemically healthy and diabetic patients, before and after endodontic cleaning and shaping by using two different irrigation techniques; the conventional one and the EndoVac system. Quantitive polymerase chain reaction (qPCR) was utilised to detect the reduction in the bacterial count. RESULTS: The EndoVac irrigation system was effective in reducing bacteria, especially Peptostreptococcus micros in the diabetic group when compared to conventional irrigation technique with a statistically significant difference. CONCLUSION: The EndoVac can be considered as a promising tool in combination with irrigant solution to defeat the bacterial colonies living in the root canal system. Additional studies ought to be done to improve the means of bacterial clearance mainly in immune-compromised individuals. PMID:28028421

  8. Emerging Trends in Microwave Processing of Spices and Herbs.

    PubMed

    Rahath Kubra, Ismail; Kumar, Devender; Jagan Mohan Rao, Lingamallu

    2016-10-02

    Today, spices are integral part of our food as they provide sensory attributes such as aroma, color, flavour and taste to food. Further their antimicrobial, antioxidant, pharmaceutical and nutritional properties are also well known. Since spices are seasonal so their availability can be extended year round by adopting different preservation techniques. Drying and extraction are most important methods for preservation and value addition to spices. There are different techniques for drying of spices with their own advantages and limitations. A novel, non-conventional technique for drying of spices is use of microwave radiation. This technique proved to be very rapid, and also provide a good quality product. Similarly, there are a number of non-conventional extraction methods in use that are all, in principle, solid-liquid extractions but which introduce some form of additional energy to the process in order to facilitate the transfer of analytes from sample to solvent. This paper reviews latest advances in the use of microwave energy for drying of spices and herbs. Also, the review describes the potential application of microwave energy for extraction of essential oil/bioactive components from spices and herbs and the advantages of microwave-assisted process over the other extraction processes generally employed for extraction. It also showcases some recent research results on microwave drying/extraction from spices and herbs.

  9. High-density Bi-Pb-Sr-Ca-Cu-O superconductor prepared by rapid thermal melt processing

    NASA Astrophysics Data System (ADS)

    Moon, B. M.; Lalevic, B.; Kear, B. H.; McCandlish, L. E.; Safari, A.; Meskoob, M.

    1989-10-01

    A high quality, dense Bi-Pb-Sr-Ca-Cu-O superconductor has been successfully synthesized by rapid thermal melt processing. Conventionally sintered pellets were melted at 1200 °C, cooled rapidly, and then annealed. As-melted samples exhibited semiconductor behavior, which upon annealing became superconducting at 115 K [Tc(zero)=105 K]. A detailed study of various processing techniques has been carried out.

  10. Non-uniformly weighted sampling for faster localized two-dimensional correlated spectroscopy of the brain in vivo

    NASA Astrophysics Data System (ADS)

    Verma, Gaurav; Chawla, Sanjeev; Nagarajan, Rajakumar; Iqbal, Zohaib; Albert Thomas, M.; Poptani, Harish

    2017-04-01

    Two-dimensional localized correlated spectroscopy (2D L-COSY) offers greater spectral dispersion than conventional one-dimensional (1D) MRS techniques, yet long acquisition times and limited post-processing support have slowed its clinical adoption. Improving acquisition efficiency and developing versatile post-processing techniques can bolster the clinical viability of 2D MRS. The purpose of this study was to implement a non-uniformly weighted sampling (NUWS) scheme for faster acquisition of 2D-MRS. A NUWS 2D L-COSY sequence was developed for 7T whole-body MRI. A phantom containing metabolites commonly observed in the brain at physiological concentrations was scanned ten times with both the NUWS scheme of 12:48 duration and a 17:04 constant eight-average sequence using a 32-channel head coil. 2D L-COSY spectra were also acquired from the occipital lobe of four healthy volunteers using both the proposed NUWS and the conventional uniformly-averaged L-COSY sequence. The NUWS 2D L-COSY sequence facilitated 25% shorter acquisition time while maintaining comparable SNR in humans (+0.3%) and phantom studies (+6.0%) compared to uniform averaging. NUWS schemes successfully demonstrated improved efficiency of L-COSY, by facilitating a reduction in scan time without affecting signal quality.

  11. The use of various X-ray fluorescence analysis modalities for the investigation of historical paintings: The case study on the Late Gothic panel painting

    NASA Astrophysics Data System (ADS)

    Bártová, H.; Trojek, T.; Čechák, T.; Šefců, R.; Chlumská, Š.

    2017-10-01

    The presence of heavy chemical elements in old pigments is possible to identify in historical paintings using X-ray fluorescence analysis (XRF). This is a non-destructive analytical method frequently used in examination of objects that require in situ analysis, where it is necessary to avoid damaging the object by taking samples. Different modalities are available, such as microanalysis, scanning selected areas, or depth profiling techniques. Surface scanning is particularly profitable since 2D element distribution maps are much more understandable than the results of individual analyses. Information on the layered structure of the painting can be also obtained by handheld portable systems. Results presented in our paper combine 2D element distribution maps obtained by scanning analysis, and depth profiling using conventional XRF. The latter is very suitable for objects of art, as it can be evaluated from data measured with portable XRF device. Depth profiling by conventional XRF is based on the differences in X-ray absorption in paint layers. The XRF technique was applied for analysis of panel paintings of the Master of the St George Altarpiece who was active in Prague in the 1470s and 1480s. The results were evaluated by taking micro-samples and performing a material analysis.

  12. Crystallization and dielectric properties of PbTiO3 based glass ceramics

    NASA Astrophysics Data System (ADS)

    Shankar, J.; Rani, G. Neeraja; Deshpande, V. K.

    2018-04-01

    Glass samples with composition (50 - X) PbO - (25 + X) TiO2 - 25 B2O3 (where X = 0, 5, 10 and 12.5 mol %) were prepared using conventional quenching technique. These glass samples were converted to glass ceramics by following two stage heat treatment schedule. The XRD results in the glass ceramics revealed the formation of tetragonal lead titanate as a major crystalline phase. The SEM results show rounded crystallite of lead titanate. The ferroelectric nature of all the glass ceramic samples is confirmed by P - E hysteresis measurements. The extended heat treatment of glass ceramic samples at 593K for 10 h exhibited saturated hysteresis loops with higher values of remnant polarization.

  13. A low-power inverter-based CMOS level-crossing analog-to-digital converter for low-frequency biosignal sensing

    NASA Astrophysics Data System (ADS)

    Tanaka, Suiki; Niitsu, Kiichi; Nakazato, Kazuo

    2016-03-01

    Low-power analog-to-digital conversion is a key technique for power-limited biomedical applications such as power-limited continuous glucose monitoring. However, a conventional uniform-sampling analog-to-digital converter (ADC) is not suitable for nonuniform biosignals. A level-crossing ADC (LC-ADC) is a promising candidate for low-power biosignal processing because of its event-driven properties. The LC-ADC acquires data by level-crossing sampling. When an input signal crosses the threshold level, the LC-ADC samples the signal. The conventional LC-ADC employs a power-hungry comparator. In this paper, we present a low-power inverter-based LC-ADC. By adjusting the threshold level of the inverter, it can be used as a threshold-fixed window comparator. By using the inverter as an alternative to a comparator, power consumption can be markedly reduced. As a result, the total power consumption is successfully reduced by 90% of that of previous LC-ADC. The inverter-based LC-ADC was found to be very suitable for use in power-limited biomedical devices.

  14. A High Performance Impedance-based Platform for Evaporation Rate Detection.

    PubMed

    Chou, Wei-Lung; Lee, Pee-Yew; Chen, Cheng-You; Lin, Yu-Hsin; Lin, Yung-Sheng

    2016-10-17

    This paper describes the method of a novel impedance-based platform for the detection of the evaporation rate. The model compound hyaluronic acid was employed here for demonstration purposes. Multiple evaporation tests on the model compound as a humectant with various concentrations in solutions were conducted for comparison purposes. A conventional weight loss approach is known as the most straightforward, but time-consuming, measurement technique for evaporation rate detection. Yet, a clear disadvantage is that a large volume of sample is required and multiple sample tests cannot be conducted at the same time. For the first time in literature, an electrical impedance sensing chip is successfully applied to a real-time evaporation investigation in a time sharing, continuous and automatic manner. Moreover, as little as 0.5 ml of test samples is required in this impedance-based apparatus, and a large impedance variation is demonstrated among various dilute solutions. The proposed high-sensitivity and fast-response impedance sensing system is found to outperform a conventional weight loss approach in terms of evaporation rate detection.

  15. Real-time RT-PCR, a necessary tool to support the diagnosis and surveillance of rotavirus in Mexico.

    PubMed

    De La Cruz Hernández, Sergio Isaac; Anaya Molina, Yazmin; Gómez Santiago, Fabián; Terán Vega, Heidi Lizbeth; Monroy Leyva, Elda; Méndez Pérez, Héctor; García Lozano, Herlinda

    2018-04-01

    Rotavirus produces diarrhea in children under 5 years old. Most of those conventional methods such as polyacrylamide gel electrophoresis (PAGE) and reverse transcription-polymerase chain reaction (RT-PCR) have been used for rotavirus detection. However, these techniques need a multi-step process to get the results. In comparison with conventional methods, the real-time RT-PCR is a highly sensitive method, which allows getting the results in only one day. In this study a real-time RT-PCR assay was tested using a panel of 440 samples from patients with acute gastroenteritis, and characterized by PAGE and RT-PCR. The results show that the real-time RT-PCR detected rotavirus from 73% of rotavirus-negative samples analyzed by PAGE and RT-PCR; thus, the percentage of rotavirus-positive samples increased to 81%. The results indicate that this real-time RT-PCR should be part of a routine analysis, and as a support of the diagnosis of rotavirus in Mexico. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Design of a practical model-observer-based image quality assessment method for CT imaging systems

    NASA Astrophysics Data System (ADS)

    Tseng, Hsin-Wu; Fan, Jiahua; Cao, Guangzhi; Kupinski, Matthew A.; Sainath, Paavana

    2014-03-01

    The channelized Hotelling observer (CHO) is a powerful method for quantitative image quality evaluations of CT systems and their image reconstruction algorithms. It has recently been used to validate the dose reduction capability of iterative image-reconstruction algorithms implemented on CT imaging systems. The use of the CHO for routine and frequent system evaluations is desirable both for quality assurance evaluations as well as further system optimizations. The use of channels substantially reduces the amount of data required to achieve accurate estimates of observer performance. However, the number of scans required is still large even with the use of channels. This work explores different data reduction schemes and designs a new approach that requires only a few CT scans of a phantom. For this work, the leave-one-out likelihood (LOOL) method developed by Hoffbeck and Landgrebe is studied as an efficient method of estimating the covariance matrices needed to compute CHO performance. Three different kinds of approaches are included in the study: a conventional CHO estimation technique with a large sample size, a conventional technique with fewer samples, and the new LOOL-based approach with fewer samples. The mean value and standard deviation of area under ROC curve (AUC) is estimated by shuffle method. Both simulation and real data results indicate that an 80% data reduction can be achieved without loss of accuracy. This data reduction makes the proposed approach a practical tool for routine CT system assessment.

  17. Vector network analyzer ferromagnetic resonance spectrometer with field differential detection

    NASA Astrophysics Data System (ADS)

    Tamaru, S.; Tsunegi, S.; Kubota, H.; Yuasa, S.

    2018-05-01

    This work presents a vector network analyzer ferromagnetic resonance (VNA-FMR) spectrometer with field differential detection. This technique differentiates the S-parameter by applying a small binary modulation field in addition to the DC bias field to the sample. By setting the modulation frequency sufficiently high, slow sensitivity fluctuations of the VNA, i.e., low-frequency components of the trace noise, which limit the signal-to-noise ratio of the conventional VNA-FMR spectrometer, can be effectively removed, resulting in a very clean FMR signal. This paper presents the details of the hardware implementation and measurement sequence as well as the data processing and analysis algorithms tailored for the FMR spectrum obtained with this technique. Because the VNA measures a complex S-parameter, it is possible to estimate the Gilbert damping parameter from the slope of the phase variation of the S-parameter with respect to the bias field. We show that this algorithm is more robust against noise than the conventional algorithm based on the linewidth.

  18. Development of a novel ultrasound-assisted headspace liquid-phase microextraction and its application to the analysis of chlorophenols in real aqueous samples.

    PubMed

    Xu, Hui; Liao, Ying; Yao, Jinrong

    2007-10-05

    A new sample pretreatment technique, ultrasound-assisted headspace liquid-phase microextraction was developed as mentioned in this paper. In the technique, the volatile analytes were headspace extracted into a small drop of solvent, which suspended on the bottom of a cone-shaped PCR tube instead of the needle tip of a microsyringe. More solvent could be suspended in the PCR tube than microsyringe due to the larger interfacial tension, thus the analysis sensitivity was significantly improved with the increase of the extractant volume. Moreover, ultrasound-assisted extraction and independent controlling temperature of the extractant and the sample were performed to enhance the extraction efficiency. Following the extraction, the solvent-loaded sample was analyzed by high-performance liquid chromatography. Chlorophenols (2-chlorophenol, 2,4-dichlorophenol and 2,6-dichlorophenol) were chosen as model analytes to investigate the feasibility of the method. The experimental conditions related to the extraction efficiency were systematically studied. Under the optimum experimental conditions, the detection limit (S/N=3), intra- and inter-day RSD were 6 ng mL(-1), 4.6%, 3.9% for 2-chlorophenol, 12 ng mL(-1), 2.4%, 8.8% for 2,4-dichlorophenol and 23 ng mL(-1), 3.3%, 5.3% for 2,6-dichlorophenol, respectively. The proposed method was successfully applied to determine chlorophenols in real aqueous samples. Good recoveries ranging from 84.6% to 100.7% were obtained. In addition, the extraction efficiency of our method and the conventional headspace liquid-phase microextraction were compared; the extraction efficiency of the former was about 21 times higher than that of the latter. The results demonstrated that the proposed method is a promising sample pretreatment approach, its advantages over the conventional headspace liquid-phase microextraction include simple setup, ease of operation, rapidness, sensitivity, precision and no cross-contamination. The method is very suitable for the analysis of trace volatile and semivolatile pollutants in real aqueous sample.

  19. Eddy current techniques for super duplex stainless steel characterization

    NASA Astrophysics Data System (ADS)

    Camerini, C.; Sacramento, R.; Areiza, M. C.; Rocha, A.; Santos, R.; Rebello, J. M.; Pereira, G.

    2015-08-01

    Super duplex stainless steel (SDSS) is a two-phase material where the microstructure consists of grains of ferrite (δ) and austenite (γ). SDSS exhibit an attractive combination of properties, such as: strength, toughness and stress corrosion cracking resistance. Nevertheless, SDSS attain these properties after a controlled solution heat treatment, leading to a similar volumetric fraction of δ and γ. Any further heat treatment, welding operation for example, can change the balance of the original phases, or may also lead to precipitation of a deleterious phase, such as sigma (σ). For these situations, the material corrosion resistance is severely impaired. In the present study, several SDSS samples with low σ phase content and non-balanced microstructure were intentionally obtained by thermally treating SDSS specimens. Electromagnetic techniques, conventional Eddy Current Testing (ECT) and Saturated Low Frequency Eddy Current (SLOFEC), were employed to characterize the SDSS samples. The results showed that ECT and SLOFEC are reliable techniques to evaluate σ phase presence in SDSS and can provide an estimation of the δ content.

  20. Structural investigation of Zn doped sodium bismuth borate glasses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhatia, V., E-mail: vijetabhatia0712@gmail.com; Kumar, D.; Singh, D.

    2016-05-06

    A series of Bismuth Borate Oxide Glass samples with composition x(ZnO):(15-x)Na{sub 2}O:15Bi{sub 2}O{sub 3}:70B{sub 2}O{sub 3} (variation in x is from 6 to 12 mole %) have been prepared by conventional melt quenching technique. All the chemicals used were of Analytical Grade. In order to verify the amorphous nature of the prepared samples the X-Ray Diffraction (XRD) was done. The physical and structural properties have been explored by using the techniques such as density, molar volume and FTIR in order to understand the effect of alkali and transition metal ions on the structure of these glasses. The results obtained bymore » these techniques are in good agreement to one another and with literature as well. With the increase in the content of ZnO, the increase in density and some variations in structural coordination (ratio of BO{sub 3} & BO{sub 4} structural units) have been observed.« less

  1. Correction of stain variations in nuclear refractive index of clinical histology specimens

    PubMed Central

    Uttam, Shikhar; Bista, Rajan K.; Hartman, Douglas J.; Brand, Randall E.; Liu, Yang

    2011-01-01

    For any technique to be adopted into a clinical setting, it is imperative that it seamlessly integrates with well-established clinical diagnostic workflow. We recently developed an optical microscopy technique—spatial-domain low-coherence quantitative phase microscopy (SL-QPM) that can extract the refractive index of the cell nucleus from the standard histology specimens on glass slides prepared via standard clinical protocols. This technique has shown great potential in detecting cancer with a better sensitivity than conventional pathology. A major hurdle in the clinical translation of this technique is the intrinsic variation among staining agents used in histology specimens, which limits the accuracy of refractive index measurements of clinical samples. In this paper, we present a simple and easily generalizable method to remove the effect of variations in staining levels on nuclear refractive index obtained with SL-QPM. We illustrate the efficacy of our correction method by applying it to variously stained histology samples from animal model and clinical specimens. PMID:22112118

  2. Study of statis and dynamic stress effects in nonlinear solids

    NASA Technical Reports Server (NTRS)

    Namkung, M.

    1985-01-01

    As the basic physical principles behind the low-field magnetoacoustic interactions have been unfolded, a new step in the present research had to be taken. First, the stress measurements began in samples obtained in real railroad wheel and rail materials. Second, the effect of texture, which is the prime obstacle of conventional NDE techniques, has been investigated. The first stage shows experimental results on these subjects again confirmed that the present technique is most suited for nondestructive stress characterization in steel components. The stress effects on the magnetoacoustic interaction obtained in a sample made from railroad rail which were very similar to those obtained previously in 1045 steel. These results being somewhat different from the results with low (1020) and high (1095) carbon steels, there seemed to be certain range of medium carbon steels having the same characteristics. Also, as expected from the model, the stress information obtained by this technique has been confirmed to be least affected by the presence of texture.

  3. Forensic identification of spilled biodiesel and its blends with petroleum oil based on fingerprinting information.

    PubMed

    Yang, Zeyu; Hollebone, Bruce P; Wang, Zhendi; Yang, Chun; Brown, Carl; Landriault, Mike

    2013-06-01

    A case study is presented for the forensic identification of several spilled biodiesels and its blends with petroleum oil using integrated forensic oil fingerprinting techniques. The integrated fingerprinting techniques combined SPE with GC/MS for obtaining individual petroleum hydrocarbons (aliphatic hydrocarbons, polyaromatic hydrocarbons and their alkylated derivatives and biomarkers), and biodiesel hydrocarbons (fatty acid methyl esters, free fatty acids, glycerol, monoacylglycerides, and free sterols). HPLC equipped with evaporative scattering laser detector was also used for identifying the compounds that conventional GC/MS could not finish. The three environmental samples (E1, E2, and E3) and one suspected source sample (S2) were dominant with vegetable oil with high acid values and low concentration of fatty acid methyl ester. The suspected source sample S2 was responsible for the three spilled samples although E1 was slightly contaminated by petroleum oil with light hydrocarbons. The suspected source sample S1 exhibited with the high content of glycerol, low content of glycerides, and high polarity, indicating its difference from the other samples. These samples may be the separated byproducts in producing biodiesel. Canola oil source is the most possible feedstock for the three environmental samples and the suspected source sample S2. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Volume and tissue composition preserving deformation of breast CT images to simulate breast compression in mammographic imaging

    NASA Astrophysics Data System (ADS)

    Han, Tao; Chen, Lingyun; Lai, Chao-Jen; Liu, Xinming; Shen, Youtao; Zhong, Yuncheng; Ge, Shuaiping; Yi, Ying; Wang, Tianpeng; Shaw, Chris C.

    2009-02-01

    Images of mastectomy breast specimens have been acquired with a bench top experimental Cone beam CT (CBCT) system. The resulting images have been segmented to model an uncompressed breast for simulation of various CBCT techniques. To further simulate conventional or tomosynthesis mammographic imaging for comparison with the CBCT technique, a deformation technique was developed to convert the CT data for an uncompressed breast to a compressed breast without altering the breast volume or regional breast density. With this technique, 3D breast deformation is separated into two 2D deformations in coronal and axial views. To preserve the total breast volume and regional tissue composition, each 2D deformation step was achieved by altering the square pixels into rectangular ones with the pixel areas unchanged and resampling with the original square pixels using bilinear interpolation. The compression was modeled by first stretching the breast in the superior-inferior direction in the coronal view. The image data were first deformed by distorting the voxels with a uniform distortion ratio. These deformed data were then deformed again using distortion ratios varying with the breast thickness and re-sampled. The deformation procedures were applied in the axial view to stretch the breast in the chest wall to nipple direction while shrinking it in the mediolateral to lateral direction re-sampled and converted into data for uniform cubic voxels. Threshold segmentation was applied to the final deformed image data to obtain the 3D compressed breast model. Our results show that the original segmented CBCT image data were successfully converted into those for a compressed breast with the same volume and regional density preserved. Using this compressed breast model, conventional and tomosynthesis mammograms were simulated for comparison with CBCT.

  5. Rapid-prenatal diagnosis through fluorescence in situ hybridization for preventing aneuploidy related birth defects

    PubMed Central

    Fauzdar, Ashish; Chowdhry, Mohit; Makroo, R. N.; Mishra, Manoj; Srivastava, Priyanka; Tyagi, Richa; Bhadauria, Preeti; Kaul, Anita

    2013-01-01

    BACKGROUND AND OBJECTIVE: Women with high-risk pregnancies are offered prenatal diagnosis through amniocentesis for cytogenetic analysis of fetal cells. The aim of this study was to evaluate the effectiveness of the rapid fluorescence in situ hybridization (FISH) technique for detecting numerical aberrations of chromosomes 13, 21, 18, X and Y in high-risk pregnancies in an Indian scenario. MATERIALS AND METHODS: A total of 163 samples were received for a FISH and/or a full karyotype for prenatal diagnosis from high-risk pregnancies. In 116 samples both conventional culture techniques for getting karyotype through G-banding techniques were applied in conjunction to FISH test using the AneuVysion kit (Abbott Molecular, Inc.), following standard recommended protocol to compare the both the techniques in our setup. RESULTS: Out of 116 patients, we got 96 normal for the five major chromosome abnormality and seven patients were found to be abnormal (04 trisomy 21, 02 monosomy X, and 01 trisomy 13) and all the FISH results correlated with conventional cytogenetics. To summarize the results of total 163 patients for the major chromosomal abnormalities analyzed by both/or cytogenetics and FISH there were 140 (86%) normal, 9 (6%) cases were abnormal and another 4 (2.5%) cases were suspicious mosaic and 10 (6%) cases of culture failure. The diagnostic detection rate with FISH in 116 patients was 97.5%. There were no false-positive and false-negative autosomal or sex chromosomal results, within our established criteria for reporting FISH signals. CONCLUSION: Rapid FISH is a reliable and prompt method for detecting numerical chromosomal aberrations and has now been implemented as a routine diagnostic procedure for detection of fetal aneuploidy in India. PMID:23901191

  6. Rapid-prenatal diagnosis through fluorescence in situ hybridization for preventing aneuploidy related birth defects.

    PubMed

    Fauzdar, Ashish; Chowdhry, Mohit; Makroo, R N; Mishra, Manoj; Srivastava, Priyanka; Tyagi, Richa; Bhadauria, Preeti; Kaul, Anita

    2013-01-01

    Women with high-risk pregnancies are offered prenatal diagnosis through amniocentesis for cytogenetic analysis of fetal cells. The aim of this study was to evaluate the effectiveness of the rapid fluorescence in situ hybridization (FISH) technique for detecting numerical aberrations of chromosomes 13, 21, 18, X and Y in high-risk pregnancies in an Indian scenario. A total of 163 samples were received for a FISH and/or a full karyotype for prenatal diagnosis from high-risk pregnancies. In 116 samples both conventional culture techniques for getting karyotype through G-banding techniques were applied in conjunction to FISH test using the AneuVysion kit (Abbott Molecular, Inc.), following standard recommended protocol to compare the both the techniques in our setup. Out of 116 patients, we got 96 normal for the five major chromosome abnormality and seven patients were found to be abnormal (04 trisomy 21, 02 monosomy X, and 01 trisomy 13) and all the FISH results correlated with conventional cytogenetics. To summarize the results of total 163 patients for the major chromosomal abnormalities analyzed by both/or cytogenetics and FISH there were 140 (86%) normal, 9 (6%) cases were abnormal and another 4 (2.5%) cases were suspicious mosaic and 10 (6%) cases of culture failure. The diagnostic detection rate with FISH in 116 patients was 97.5%. There were no false-positive and false-negative autosomal or sex chromosomal results, within our established criteria for reporting FISH signals. Rapid FISH is a reliable and prompt method for detecting numerical chromosomal aberrations and has now been implemented as a routine diagnostic procedure for detection of fetal aneuploidy in India.

  7. Intraosseous anesthesia with solution injection controlled by a computerized system versus conventional oral anesthesia: a preliminary study.

    PubMed

    Beneito-Brotons, Rut; Peñarrocha-Oltra, David; Ata-Ali, Javier; Peñarrocha, María

    2012-05-01

    To compare a computerized intraosseous anesthesia system with the conventional oral anesthesia techniques, and analyze the latency and duration of the anesthetic effect and patient preference. A simple-blind prospective study was made between March 2007 and May 2008. Each patient was subjected to two anesthetic techniques: conventional and intraosseous using the Quicksleeper® system (DHT, Cholet, France). A split-mouth design was adopted in which each patient underwent treatment of a tooth with one of the techniques, and treatment of the homologous contralateral tooth with the other technique. The treatments consisted of restorations, endodontic procedures and simple extractions. The study series comprised 12 females and 18 males with a mean age of 36.8 years. The 30 subjects underwent a total of 60 anesthetic procedures. Intraosseous and conventional oral anesthesia caused discomfort during administration in 46.3% and 32.1% of the patients, respectively. The latency was 7.1±2.23 minutes for the conventional technique and 0.48±0.32 for intraosseous anesthesia--the difference being statistically significant. The depth of the anesthetic effect was sufficient to allow the patients to tolerate the dental treatments. The duration of the anesthetic effect in soft tissues was 199.3 minutes with the conventional technique versus only 1.6 minutes with intraosseous anesthesia--the difference between the two techniques being statistically significant. Most of the patients (69.7%) preferred intraosseous anesthesia. The described intraosseous anesthetic system is effective, with a much shorter latency than the conventional technique, sufficient duration of anesthesia to perform the required dental treatments, and with a much lesser soft tissue anesthetic effect. Most of the patients preferred intraosseous anesthesia.

  8. Computer-assisted versus conventional free fibula flap technique for craniofacial reconstruction: an outcomes comparison.

    PubMed

    Seruya, Mitchel; Fisher, Mark; Rodriguez, Eduardo D

    2013-11-01

    There has been rising interest in computer-aided design/computer-aided manufacturing for preoperative planning and execution of osseous free flap reconstruction. The purpose of this study was to compare outcomes between computer-assisted and conventional fibula free flap techniques for craniofacial reconstruction. A two-center, retrospective review was carried out on patients who underwent fibula free flap surgery for craniofacial reconstruction from 2003 to 2012. Patients were categorized by the type of reconstructive technique: conventional (between 2003 and 2009) or computer-aided design/computer-aided manufacturing (from 2010 to 2012). Demographics, surgical factors, and perioperative and long-term outcomes were compared. A total of 68 patients underwent microsurgical craniofacial reconstruction: 58 conventional and 10 computer-aided design and manufacturing fibula free flaps. By demographics, patients undergoing the computer-aided design/computer-aided manufacturing method were significantly older and had a higher rate of radiotherapy exposure compared with conventional patients. Intraoperatively, the median number of osteotomies was significantly higher (2.0 versus 1.0, p=0.002) and the median ischemia time was significantly shorter (120 minutes versus 170 minutes, p=0.004) for the computer-aided design/computer-aided manufacturing technique compared with conventional techniques; operative times were shorter for patients undergoing the computer-aided design/computer-aided manufacturing technique, although this did not reach statistical significance. Perioperative and long-term outcomes were equivalent for the two groups, notably, hospital length of stay, recipient-site infection, partial and total flap loss, and rate of soft-tissue and bony tissue revisions. Microsurgical craniofacial reconstruction using a computer-assisted fibula flap technique yielded significantly shorter ischemia times amidst a higher number of osteotomies compared with conventional techniques. Therapeutic, III.

  9. Intraosseous anesthesia with solution injection controlled by a computerized system versus conventional oral anesthesia: A preliminary study

    PubMed Central

    Beneito-Brotons, Rut; Peñarrocha-Oltra, David; Ata-Ali, Javier

    2012-01-01

    Objective: To compare a computerized intraosseous anesthesia system with the conventional oral anesthesia techniques, and analyze the latency and duration of the anesthetic effect and patient preference. Design: A simple-blind prospective study was made between March 2007 and May 2008. Each patient was subjected to two anesthetic techniques: conventional and intraosseous using the Quicksleeper® system (DHT, Cholet, France). A split-mouth design was adopted in which each patient underwent treatment of a tooth with one of the techniques, and treatment of the homologous contralateral tooth with the other technique. The treatments consisted of restorations, endodontic procedures and simple extractions. Results: The study series comprised 12 females and 18 males with a mean age of 36.8 years. The 30 subjects underwent a total of 60 anesthetic procedures. Intraosseous and conventional oral anesthesia caused discomfort during administration in 46.3% and 32.1% of the patients, respectively. The latency was 7.1±2.23 minutes for the conventional technique and 0.48±0.32 for intraosseous anesthesia – the difference being statistically significant. The depth of the anesthetic effect was sufficient to allow the patients to tolerate the dental treatments. The duration of the anesthetic effect in soft tissues was 199.3 minutes with the conventional technique versus only 1.6 minutes with intraosseous anesthesia – the difference between the two techniques being statistically significant. Most of the patients (69.7%) preferred intraosseous anesthesia. Conclusions: The described intraosseous anesthetic system is effective, with a much shorter latency than the conventional technique, sufficient duration of anesthesia to perform the required dental treatments, and with a much lesser soft tissue anesthetic effect. Most of the patients preferred intraosseous anesthesia. Key words:Anesthesia, intraosseous, oral anesthesia, infiltrating, mandibular block, Quicksleeper®. PMID:22143722

  10. ESEM results and changes in wettability patterns within soil: three years irrigation with slightly-salted water

    NASA Astrophysics Data System (ADS)

    Valdes-Abellan, Javier; Candela, Lucila; Medero, Gabriela; Buckman, Jim; Hasnayn, Mohammad M.

    2015-04-01

    Impacts on soil and aquifer media from the use of non-conventional water (treated wastewater-TWW, desalted) for irrigation have been widely studied in the last years . A number of contributions have focused on the impacts derived from the use of TWW (Assouline and Narkis, 2013; Lahav et al., 2010; Xu et al., 2010). Changes in soil hydraulic conductivity and clogging processes have been studied in laboratory experiments from soil columns (Lado and Ben-Hur, 2010) and at field scale (Costa, 1999; Minhas et al., 1994). Irrigation with non-conventional water may also lead to the occurrence of contaminants, a major current environmental concern (Valdes-Abellan et al., 2013). Previous studies have considered impacts in a uniform soil media pore structure; less attention has been paid at a microscopic scale and the influence that high-salinity water may have on wettability of soil. Environmental scanning electron microscopy (ESEM) is a useful technique to be applied in soil science to analyse microscopic changes in soil structure or soil wetting patterns. Research applying this technology for wet systems (Donald, 1998) or porous media (Ali et al., 1995) is available, however as far as we know research on soil impacts due to long term irrigation with saline or non-conventional water are much less common. The dynamic mode of the ESEM allows changes of samples from wet to dry by modifying the water vapour pressure and to observe the wetting and drying patterns and interactions between the solid and liquid phase in the soil (Lourenço et al., 2008). Preliminary results of the study at a microscopic scale of soil samples collected before and after three year irrigation with slightly salted water in an experimental plot setup in semi-arid climatic conditions (Alicante, SE Spain) are presented. We will show the micro-structure of soil and undertake a preliminary investigation of wetting and drying of samples using ESEM techniques Differences in the water vapour pressure value at which complete saturation is achieved was detected, being lower in the 3-years irrigated samples compared with the initial ones. Besides, velocity in which saturation took place was different: initial samples saturation process were developed very quickly, as triggered by a critical shift in the water vapour pressure value and much gradual process were develop in the 3-years irrigated sample when saturation started earlier.

  11. Low energy cyclotron for radiocarbon dating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Welch, J.J.

    1984-12-01

    The measurement of naturally occurring radioisotopes whose half lives are less than a few hundred million years but more than a few years provides information about the temporal behavior of geologic and climatic processes, the temporal history of meteoritic bodies as well as the production mechanisms of these radioisotopes. A new extremely sensitive technique for measuring these radioisotopes at tandem Van de Graaff and cyclotron facilities has been very successful though the high cost and limited availability have been discouraging. We have built and tested a low energy cyclotron for radiocarbon dating similar in size to a conventional mass spectrometer.more » These tests clearly show that with the addition of a conventional ion source, the low energy cyclotron can perform the extremely high sensitivity /sup 14/C measurements that are now done at accelerator facilities. We found that no significant background is present when the cyclotron is tuned to accelerate /sup 14/C negative ions and the transmission efficiency is adequate to perform radiocarbon dating on milligram samples of carbon. The internal ion source used did not produce sufficient current to detect /sup 14/C directly at modern concentrations. We show how a conventional carbon negative ion source, located outside the cyclotron magnet, would produce sufficient beam and provide for quick sampling to make radiocarbon dating milligram samples with a modest laboratory instrument feasible.« less

  12. Application of CRAFT (complete reduction to amplitude frequency table) in nonuniformly sampled (NUS) 2D NMR data processing.

    PubMed

    Krishnamurthy, Krish; Hari, Natarajan

    2017-09-15

    The recently published CRAFT (complete reduction to amplitude frequency table) technique converts the raw FID data (i.e., time domain data) into a table of frequencies, amplitudes, decay rate constants, and phases. It offers an alternate approach to decimate time-domain data, with minimal preprocessing step. It has been shown that application of CRAFT technique to process the t 1 dimension of the 2D data significantly improved the detectable resolution by its ability to analyze without the use of ubiquitous apodization of extensively zero-filled data. It was noted earlier that CRAFT did not resolve sinusoids that were not already resolvable in time-domain (i.e., t 1 max dependent resolution). We present a combined NUS-IST-CRAFT approach wherein the NUS acquisition technique (sparse sampling technique) increases the intrinsic resolution in time-domain (by increasing t 1 max), IST fills the gap in the sparse sampling, and CRAFT processing extracts the information without loss due to any severe apodization. NUS and CRAFT are thus complementary techniques to improve intrinsic and usable resolution. We show that significant improvement can be achieved with this combination over conventional NUS-IST processing. With reasonable sensitivity, the models can be extended to significantly higher t 1 max to generate an indirect-DEPT spectrum that rivals the direct observe counterpart. Copyright © 2017 John Wiley & Sons, Ltd.

  13. A structural investigation of a synthesized precursor for optical fiber applications; the heterobimetallic ErNb 2(OPr i) 13

    NASA Astrophysics Data System (ADS)

    Engholm, M.; Norin, L.; Edvardsson, S.; Lashgari, K.; Westin, G.

    2006-12-01

    A structural investigation of a synthesized precursor in a silica glass matrix is performed. Silica soot samples are doped with the heterobimetallic precursor ErNb 2(OPr i) 13 by using a conventional solution doping technique and heat treatments to different temperatures. The precursor has also been introduced into a silica fiber preform by using the modified chemical vapor deposition technique. Analyses are made by using ultraviolet-visible-near infrared absorption spectroscopy, scanning electron microscopy, energy dispersive spectroscopy and powder X-ray diffraction. It is concluded that an immiscible system of ErNbO 4 crystallites and Nb 2O 5 is formed in the silica soot samples at high temperatures. Colloidal particles of ErNbO 4 are also formed in the silica glass fiber preform showing interesting features.

  14. Hall versus conventional stainless steel crown techniques: in vitro investigation of marginal fit and microleakage using three different luting agents.

    PubMed

    Erdemci, Zeynep Yalçınkaya; Cehreli, S Burçak; Tirali, R Ebru

    2014-01-01

    This study's purpose was to investigate microleakage and marginal discrepancies in stainless steel crowns (SSCs) placed using conventional and Hall techniques and cemented with three different luting agents. Seventy-eight human primary maxillary second molars were randomly assigned to two groups (N=39), and SSCs were applied either with the Hall or conventional technique. These two groups were further subgrouped according to the material used for crown cementation (N=13 per group). Two specimens in each group were processed for scanning electron microscopy investigation. The extent of microleakage and marginal fit was quantified in millimeters on digitally photographed sections using image analysis software. The data were compared with a two-way independent and a two-way mixed analysis of variance (P=.05). The scores in the Hall group were significantly worse than those in the conventional technique group (P<.05). In both groups, resin cement displayed the lowest extent of microleakage, followed by glass ionomer and polycarboxylate cements (P<.05). Stainless steel crowns applied using the Hall technique displayed higher microleakage scores than those applied using the conventional technique, regardless of the cementation material. When the interaction of the material and technique was assessed, resin cement presented as the best choice for minimizing microleakage in both techniques.

  15. Acoustic emission strand burning technique for motor burning rate prediction

    NASA Technical Reports Server (NTRS)

    Christensen, W. N.

    1978-01-01

    An acoustic emission (AE) method is being used to measure the burning rate of solid propellant strands. This method has a precision of 0.5% and excellent burning rate correlation with both subscale and large rocket motors. The AE procedure burns the sample under water and measures the burning rate from the acoustic output. The acoustic signal provides a continuous readout during testing, which allows complete data analysis rather than the start-stop clockwires used by the conventional method. The AE method helps eliminate such problems as inhibiting the sample, pressure increase and temperature rise, during testing.

  16. The design of a new concept chromatography column.

    PubMed

    Camenzuli, Michelle; Ritchie, Harald J; Ladine, James R; Shalliker, R Andrew

    2011-12-21

    Active Flow Management is a new separation technique whereby the flow of mobile phase and the injection of sample are introduced to the column in a manner that allows migration according to the principles of the infinite diameter column. A segmented flow outlet fitting allows for the separation of solvent or solute that elutes along the central radial section of the column from that of the sample or solvent that elutes along the wall region of the column. Separation efficiency on the analytical scale is increased by 25% with an increase in sensitivity by as much as 52% compared to conventional separations.

  17. An Intrinsic Algorithm for Parallel Poisson Disk Sampling on Arbitrary Surfaces.

    PubMed

    Ying, Xiang; Xin, Shi-Qing; Sun, Qian; He, Ying

    2013-03-08

    Poisson disk sampling plays an important role in a variety of visual computing, due to its useful statistical property in distribution and the absence of aliasing artifacts. While many effective techniques have been proposed to generate Poisson disk distribution in Euclidean space, relatively few work has been reported to the surface counterpart. This paper presents an intrinsic algorithm for parallel Poisson disk sampling on arbitrary surfaces. We propose a new technique for parallelizing the dart throwing. Rather than the conventional approaches that explicitly partition the spatial domain to generate the samples in parallel, our approach assigns each sample candidate a random and unique priority that is unbiased with regard to the distribution. Hence, multiple threads can process the candidates simultaneously and resolve conflicts by checking the given priority values. It is worth noting that our algorithm is accurate as the generated Poisson disks are uniformly and randomly distributed without bias. Our method is intrinsic in that all the computations are based on the intrinsic metric and are independent of the embedding space. This intrinsic feature allows us to generate Poisson disk distributions on arbitrary surfaces. Furthermore, by manipulating the spatially varying density function, we can obtain adaptive sampling easily.

  18. Decision rules for unbiased inventory estimates

    NASA Technical Reports Server (NTRS)

    Argentiero, P. D.; Koch, D.

    1979-01-01

    An efficient and accurate procedure for estimating inventories from remote sensing scenes is presented. In place of the conventional and expensive full dimensional Bayes decision rule, a one-dimensional feature extraction and classification technique was employed. It is shown that this efficient decision rule can be used to develop unbiased inventory estimates and that for large sample sizes typical of satellite derived remote sensing scenes, resulting accuracies are comparable or superior to more expensive alternative procedures. Mathematical details of the procedure are provided in the body of the report and in the appendix. Results of a numerical simulation of the technique using statistics obtained from an observed LANDSAT scene are included. The simulation demonstrates the effectiveness of the technique in computing accurate inventory estimates.

  19. An improved switching converter model. Ph.D. Thesis. Final Report

    NASA Technical Reports Server (NTRS)

    Shortt, D. J.

    1982-01-01

    The nonlinear modeling and analysis of dc-dc converters in the continuous mode and discontinuous mode was done by averaging and discrete sampling techniques. A model was developed by combining these two techniques. This model, the discrete average model, accurately predicts the envelope of the output voltage and is easy to implement in circuit and state variable forms. The proposed model is shown to be dependent on the type of duty cycle control. The proper selection of the power stage model, between average and discrete average, is largely a function of the error processor in the feedback loop. The accuracy of the measurement data taken by a conventional technique is affected by the conditions at which the data is collected.

  20. Techniques for controlling variability in gram staining of obligate anaerobes.

    PubMed Central

    Johnson, M J; Thatcher, E; Cox, M E

    1995-01-01

    Identification of anaerobes recovered from clinical samples is complicated by the fact that certain gram-positive anaerobes routinely stain gram negative; Peptostreptococcus asaccharolyticus, Eubacterium plautii, Clostridium ramosum, Clostridium symbiosum, and Clostridium clostridiiforme are among the nonconformists with regard to conventional Gram-staining procedures. Accurate Gram staining of American Type Culture Collection strains of these anaerobic bacteria is possible by implementing fixing and staining techniques within a gloveless anaerobic chamber. Under anaerobic conditions, gram-positive staining occurred in all test organisms with "quick" fixing techniques with both absolute methanol and formalin. The results support the hypothesis that, when anaerobic bacteria are exposed to oxygen, a breakdown of the physical integrity of the cell wall occurs, introducing Gram stain variability in gram-positive anaerobes. PMID:7538512

  1. Mercury Distribution in the Deûle River (Northern France) Measured by the Diffusive Gradients in Thin Films Technique and Conventional Methods.

    PubMed

    Diviš, Pavel; Kadlecová, Milada; Ouddane, Baghdad

    2016-05-01

    The distribution of mercury in surface water and in sediment from Deûle River in Northern France was studied by application of conventional sampling methods and by diffusive gradients in thin films technique (DGT). Concentration of total dissolved mercury in surface water was 20.8 ± 0.8 ng l(-1). The particulate mercury concentration was 6.2 ± 0.6 µg g(-1). The particulate mercury was accumulated in sediment (9.9 ± 2.3 mg kg(-1)), and it was transformed by methylating bacteria to methylmercury, mainly in the first 2-cm layer of the sediment. Total dissolved concentration of mercury in sediment pore water obtained by application of centrifugation extraction was 17.6 ± 4.1 ng l(-1), and it was comparable with total dissolved pore water mercury concentration measured by DGT probe containing Duolite GT-73 resin gel (18.2 ± 4.3 ng l(-1)), taking the sediment heterogeneity and different principles of the applied methods into account. By application of two DGT probes with different resin gels specific for mercury, it was found that approximately 30% of total dissolved mercury in sediment pore water was present in labile forms easy available for biota. The resolution of mercury DGT depth profiles was 0.5 cm, which allows, unlike conventional techniques, to study the connection of the geochemical cycle of mercury with geochemical cycles of iron and manganese.

  2. Ultrasonic standing wave preparation of a liquid cell for glucose measurements in urine by midinfrared spectroscopy and potential application to smart toilets.

    PubMed

    Yamamoto, Naoyuki; Kawashima, Natsumi; Kitazaki, Tomoya; Mori, Keita; Kang, Hanyue; Nishiyama, Akira; Wada, Kenji; Ishimaru, Ichiro

    2018-05-01

    Smart toilets could be used to monitor different components of urine in daily life for early detection of lifestyle-related diseases and prompt provision of treatment. For analysis of biological samples such as urine by midinfrared spectroscopy, thin-film samples like liquid cells are needed because of the strong absorption of midinfrared light by water. Conventional liquid cells or fixed cells are prepared based on the liquid membrane method and solution technique, but these are not quantitative and are difficult to set up and clean. We generated an ultrasonic standing wave reflection plane in a sample and produced an ultrasonic liquid cell. In this cell, the thickness of the optical path length was adjustable, as in the conventional method. The reflection plane could be generated at an arbitrary depth and internal reflected light could be detected by changing the frequency of the ultrasonic wave. We could generate refractive index boundaries using the density difference created by the ultrasonic standing wave. Creation of the reflection plane in the sample was confirmed by optical coherence tomography. Using the proposed method and midinfrared spectroscopy, we discriminated between normal urine samples spiked with glucose at different concentrations and obtained a high correlation coefficient. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  3. Accuracy of ringless casting and accelerated wax-elimination technique: a comparative in vitro study.

    PubMed

    Prasad, Rahul; Al-Keraif, Abdulaziz Abdullah; Kathuria, Nidhi; Gandhi, P V; Bhide, S V

    2014-02-01

    The purpose of this study was to determine whether the ringless casting and accelerated wax-elimination techniques can be combined to offer a cost-effective, clinically acceptable, and time-saving alternative for fabricating single unit castings in fixed prosthodontics. Sixty standardized wax copings were fabricated on a type IV stone replica of a stainless steel die. The wax patterns were divided into four groups. The first group was cast using the ringless investment technique and conventional wax-elimination method; the second group was cast using the ringless investment technique and accelerated wax-elimination method; the third group was cast using the conventional metal ring investment technique and conventional wax-elimination method; the fourth group was cast using the metal ring investment technique and accelerated wax-elimination method. The vertical marginal gap was measured at four sites per specimen, using a digital optical microscope at 100× magnification. The results were analyzed using two-way ANOVA to determine statistical significance. The vertical marginal gaps of castings fabricated using the ringless technique (76.98 ± 7.59 μm) were significantly less (p < 0.05) than those castings fabricated using the conventional metal ring technique (138.44 ± 28.59 μm); however, the vertical marginal gaps of the conventional (102.63 ± 36.12 μm) and accelerated wax-elimination (112.79 ± 38.34 μm) castings were not statistically significant (p > 0.05). The ringless investment technique can produce castings with higher accuracy and can be favorably combined with the accelerated wax-elimination method as a vital alternative to the time-consuming conventional technique of casting restorations in fixed prosthodontics. © 2013 by the American College of Prosthodontists.

  4. Acoustically levitated droplets: a contactless sampling method for fluorescence studies.

    PubMed

    Leiterer, Jork; Grabolle, Markus; Rurack, Knut; Resch-Genger, Ute; Ziegler, Jan; Nann, Thomas; Panne, Ulrich

    2008-01-01

    Acoustic levitation is used as a new tool to study concentration-dependent processes in fluorescence spectroscopy. With this technique, small amounts of liquid and solid samples can be measured without the need for sample supports or containers, which often limits signal acquisition and can even alter sample properties due to interactions with the support material. We demonstrate that, because of the small sample volume, fluorescence measurements at high concentrations of an organic dye are possible without the limitation of inner-filter effects, which hamper such experiments in conventional, cuvette-based measurements. Furthermore, we show that acoustic levitation of liquid samples provides an experimentally simple way to study distance-dependent fluorescence modulations in semiconductor nanocrystals. The evaporation of the solvent during levitation leads to a continuous increase of solute concentration and can easily be monitored by laser-induced fluorescence.

  5. Measurement of surface microtopography

    NASA Technical Reports Server (NTRS)

    Wall, S. D.; Farr, T. G.; Muller, J.-P.; Lewis, P.; Leberl, F. W.

    1991-01-01

    Acquisition of ground truth data for use in microwave interaction modeling requires measurement of surface roughness sampled at intervals comparable to a fraction of the microwave wavelength and extensive enough to adequately represent the statistics of a surface unit. Sub-centimetric measurement accuracy is thus required over large areas, and existing techniques are usually inadequate. A technique is discussed for acquiring the necessary photogrammetric data using twin film cameras mounted on a helicopter. In an attempt to eliminate tedious data reduction, an automated technique was applied to the helicopter photographs, and results were compared to those produced by conventional stereogrammetry. Derived root-mean-square (RMS) roughness for the same stereo-pair was 7.5 cm for the automated technique versus 6.5 cm for the manual method. The principal source of error is probably due to vegetation in the scene, which affects the automated technique but is ignored by a human operator.

  6. Application of surface plasmon resonance for the detection of carbohydrates, glycoconjugates, and measurement of the carbohydrate-specific interactions: a comparison with conventional analytical techniques. A critical review.

    PubMed

    Safina, Gulnara

    2012-01-27

    Carbohydrates (glycans) and their conjugates with proteins and lipids contribute significantly to many biological processes. That makes these compounds important targets to be detected, monitored and identified. The identification of the carbohydrate content in their conjugates with proteins and lipids (glycoforms) is often a challenging task. Most of the conventional instrumental analytical techniques are time-consuming and require tedious sample pretreatment and utilising various labeling agents. Surface plasmon resonance (SPR) has been intensively developed during last two decades and has received the increasing attention for different applications, from the real-time monitoring of affinity bindings to biosensors. SPR does not require any labels and is capable of direct measurement of biospecific interaction occurring on the sensing surface. This review provides a critical comparison of modern analytical instrumental techniques with SPR in terms of their analytical capabilities to detect carbohydrates, their conjugates with proteins and lipids and to study the carbohydrate-specific bindings. A few selected examples of the SPR approaches developed during 2004-2011 for the biosensing of glycoforms and for glycan-protein affinity studies are comprehensively discussed. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Automation of a flocculation test for syphilis on Groupamatic equipment.

    PubMed Central

    Garretta, M; Paris-Hamelin, A; Gener, J; Muller, A; Matte, C; Vaisman, A

    1975-01-01

    A flocculation reaction employing a cardiolipid antigen was used for syphilis screening on Groupamatic equipment in parallel with conventional screening reactions: Kolmer CF, RPCF, Kahn, Kline, and RPR. The positive samples were confirmed by FTA-200, FTA-ABS, TPI, and in some cases by TPHA. There were 5,212 known samples which had already been tested by all methods and of which 1,648 were positive, and 58,636 screened samples including 65 positives. Half of the samples in the first series were taken without anticoagulant; the remainder were collected in potassium EDTA. The percentage of false positives with the Groupamatic was about 1-4 per cent. The percentage of false negatives among positve (greater than or equal+) samples varied from 0-18 to 1-3 per cent.; on the other hand the sensitivity was less good for samples giving doubtful and/or dissociated reactions in conventional screening reactions. The specificity and sensitivity of this technique are acceptable for a blood transfusion centre. The reproducibility is excellent and the automatic reading of results accurate. Additional advantages are rapidity (340 samples processed per hour); simultaneous performance of eleven other immunohaematological reactions; no contamination between samples; automatic reading, interpretation, and print-out of results; and saving of time because samples are not filed sequentially and are automatically identified when the results are obtained. Although the importance of syphilis in blood transfusion seems small, estimates of the risk are difficult and further investigations are planned. Images PMID:1098731

  8. Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization

    PubMed Central

    Sun, Xuefei; Kelly, Ryan T.; Danielson, William F.; Agrawal, Nitin; Tang, Keqi; Smith, Richard D.

    2011-01-01

    A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersection geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, little sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed. PMID:21520147

  9. [The anesthetic effects of Gow-Gates technique of inferior alveolar nerve block in impacted mandibular third molar extraction].

    PubMed

    Yang, Jieping; Liu, Wei; Gao, Qinghong

    2013-08-01

    To evaluate the anesthetic effects and safety of Gow-Gates technique of inferior alveolar nerve block in impacted mandibular third molar extraction. A split-mouth study was designed. The bilateral impacted mandibular third molar of 32 participants were divided into Gow-Gates technique of inferior alveolar nerve block (Gow-Gates group) and conventional technique of inferior alveolar nerve block (conventional group) randomly with third molar extracted. The anesthetic effects and adverse events were recorded. All the participants completed the research. The anesthetic success rate was 96.9% in Gow-Gates group and 90.6% in conventional group with no statistical difference ( P= 0.317); but when comparing the anesthesia grade, Gow-Gates group had a 96.9% of grade A and B, and conventional group had a rate of 78.1% (P = 0.034). And the Gow-Gates group had a much lower withdrawn bleeding than conventional group (P = 0.025). Two groups had no hematoma. Gow-Gates technique had a reliable anesthesia effects and safety in impacted mandibular third molar extraction and could be chosen as a candidate for the conventional inferior alveolar nerve block.

  10. Determination of finasteride and its metabolite in urine by dispersive liquid-liquid microextraction combined with field-enhanced sample stacking and sweeping.

    PubMed

    Chen, Chun-Hsien; Chao, Yu-Ying; Lin, Yi-Hui; Chen, Yen-Ling

    2018-04-27

    The on-line preconcentration technique of field-enhanced sample stacking and sweeping (FESS-sweeping) are combined with dispersive liquid-liquid microextraction (DLLME) to monitor the concentrations of finasteride, which is used in the treatment of androgenetic alopecia, and its metabolite, finasteride carboxylic acid (M3), in urine samples. DLLME is used to concentrate and eliminate the interferences of urine samples and uses chloroform as an extracting solvent and acetonitrile as a disperser solvent. A high conductivity buffer (HCB) was introduced into capillary and then sample plug (90.7% capillary length) was injected into capillary. After applying voltage, the sodium dodecyl sulfate (SDS) swept the analytes from the low conductivity sample solution into HCB. The analytes were concentrated on the field-enhanced sample stacking boundary. The limit of detection for the analytes is 20 ng mL -1 . The sensitivity enrichment of finasteride and M3 are 362-fold and 480-fold, respectively, compared with the conventional MEKC method. The on-line preconcentration technique of field-enhanced sample stacking and sweeping possess good selectivity because the endogenous steroid did not interfere the detection of finasteride and M3. The analytical technique is applied to investigate the concentrations in urine samples from patients who have been administered finasteride for the treatment of androgenetic alopecia; the amount of M3 detected in 12 h was 72.69 ± 4.18 μg. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Qualitative evaluation of maternal milk and commercial infant formulas via LIBS.

    PubMed

    Abdel-Salam, Z; Al Sharnoubi, J; Harith, M A

    2013-10-15

    This study focuses on the use of laser-induced breakdown spectroscopy (LIBS) for the evaluation of the nutrients in maternal milk and some commercially available infant formulas. The results of such evaluation are vital for adequate and healthy feeding for babies during lactation period. Laser-induced breakdown spectroscopy offers special advantages in comparison to the other conventional analytical techniques. Specifically, LIBS is a straightforward technique that can be used in situ to provide qualitative analytical information in few minutes for the samples under investigation without preparation processes. The samples studied in the current work were maternal milk samples collected during the first 3 months of lactation (not colostrum milk) and samples from six different types of commercially available infant formulas. The samples' elemental composition has been compared with respect to the relative abundance of the elements of nutrition importance, namely Mg, Ca, Na, and Fe using their spectral emission lines in the relevant LIBS spectra. In addition, CN and C2 molecular emission bands in the same spectra have been studied as indicators of proteins content in the samples. The obtained analytical results demonstrate the higher elemental contents of the maternal milk compared with the commercial formulas samples. Similar results have been obtained as for the proteins content. It has been also shown that calcium and proteins have similar relative concentration trends in the studied samples. This work demonstrates the feasibility of adopting LIBS as a fast, safe, less costly technique evaluating qualitatively the nutrients content of both maternal and commercial milk samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Space charge distributions in insulating polymers: A new non-contacting way of measurement.

    PubMed

    Marty-Dessus, D; Ziani, A C; Petre, A; Berquez, L

    2015-04-01

    A new technique for the determination of space charge profiles in insulating polymers is proposed. Based on the evolution of an existing thermal wave technique called Focused Laser Intensity Modulation Method ((F)LIMM), it allows non-contact measurements on thin films exhibiting an internal charge to be studied. An electrostatic model taking into account the new sample-cell geometry proposed was first developed. It has been shown, in particular, that it was theoretically possible to calculate the internal charge from experimental measurements while allowing an evaluation of the air layer appearing between the sample and the electrode when non-contact measurements are performed. These predictions were confirmed by an experimental implementation for two thin polymer samples (25 μm-polyvinylidenefluoride and 50 μm-polytetrafluoroethylene (PTFE)) used as tests. In these cases, minimum air-layer thickness was determined with an accuracy of 3% and 20%, respectively, depending on the signal-to-noise ratio during the experimental procedure. In order to illustrate the reachable possibilities of this technique, 2D and 3D cartographies of a negative space charge implanted by electron beam within the PTFE test sample were depicted: like in conventional (F)LIMM, a multidimensional representation of a selectively implanted charge remains possible at a few microns depth, but using a non-contacting way of measurement.

  13. [Potentials in the regionalization of health indicators using small-area estimation methods : Exemplary results based on the 2009, 2010 and 2012 GEDA studies].

    PubMed

    Kroll, Lars Eric; Schumann, Maria; Müters, Stephan; Lampert, Thomas

    2017-12-01

    Nationwide health surveys can be used to estimate regional differences in health. Using traditional estimation techniques, the spatial depth for these estimates is limited due to the constrained sample size. So far - without special refreshment samples - results have only been available for larger populated federal states of Germany. An alternative is regression-based small-area estimation techniques. These models can generate smaller-scale data, but are also subject to greater statistical uncertainties because of the model assumptions. In the present article, exemplary regionalized results based on the studies "Gesundheit in Deutschland aktuell" (GEDA studies) 2009, 2010 and 2012, are compared to the self-rated health status of the respondents. The aim of the article is to analyze the range of regional estimates in order to assess the usefulness of the techniques for health reporting more adequately. The results show that the estimated prevalence is relatively stable when using different samples. Important determinants of the variation of the estimates are the achieved sample size on the district level and the type of the district (cities vs. rural regions). Overall, the present study shows that small-area modeling of prevalence is associated with additional uncertainties compared to conventional estimates, which should be taken into account when interpreting the corresponding findings.

  14. Detection of Wuchereria bancrofti DNA in paired serum and urine samples using polymerase chain reaction-based systems.

    PubMed

    Ximenes, Camila; Brandão, Eduardo; Oliveira, Paula; Rocha, Abraham; Rego, Tamisa; Medeiros, Rafael; Aguiar-Santos, Ana; Ferraz, João; Reis, Christian; Araujo, Paulo; Carvalho, Luiz; Melo, Fabio L

    2014-12-01

    The Global Program for the Elimination of Lymphatic Filariasis (GPELF) aims to eliminate this disease by the year 2020. However, the development of more specific and sensitive tests is important for the success of the GPELF. The present study aimed to standardise polymerase chain reaction (PCR)-based systems for the diagnosis of filariasis in serum and urine. Twenty paired biological urine and serum samples from individuals already known to be positive for Wuchereria bancrofti were collected during the day. Conventional PCR and semi-nested PCR assays were optimised. The detection limit of the technique for purified W. bancrofti DNA extracted from adult worms was 10 fg for the internal systems (WbF/Wb2) and 0.1 fg by using semi-nested PCR. The specificity of the primers was confirmed experimentally by amplification of 1 ng of purified genomic DNA from other species of parasites. Evaluation of the paired urine and serum samples by the semi-nested PCR technique indicated only two of the 20 tested individuals were positive, whereas the simple internal PCR system (WbF/Wb2), which has highly promising performance, revealed that all the patients were positive using both samples. This study successfully demonstrated the possibility of using the PCR technique on urine for the diagnosis of W. bancrofti infection.

  15. Sensitive determination of polycyclic aromatic hydrocarbons in water samples by HPLC coupled with SPE based on graphene functionalized with triethoxysilane.

    PubMed

    Huang, Ke-Jing; Li, Jing; Liu, Yan-Ming; Wang, Lan

    2013-02-01

    The graphene functionalized with (3-aminopropyl) triethoxysilane was synthesized by a simple hydrothermal reaction and applied as SPE sorbents to extract trace polycyclic aromatic hydrocarbons (PAHs) from environmental water samples. These sorbents possess high adsorption capacity and extraction efficiency due to strong adsorption ability of carbon materials and large specific surface area of nanoparticles, and only 10 mg of sorbents are required to extract PAHs from 100 mL water samples. Several condition parameters, such as eluent and its volume, adsorbent amount, sample volume, sample pH, and sample flow rate, were optimized to achieve good sensitivity and precision. Under the optimized extraction conditions, the method showed good linearity in the range of 1-100 μg/L, repeatability of the extraction (the RSDs were between 1.8 and 2.9%, n = 6), and satisfactory detection limits of 0.029-0.1 μg/L. The recoveries of PAHs spiked in environmental water samples ranged from 84.6 to 109.5%. All these results demonstrated that this new SPE technique was a viable alternative to conventional enrichment techniques for the extraction and analysis of PAHs in complex samples. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Bench-Top Feasibility Testing of a Novel Percutaneous Renal Access Technique: The Laser Direct Alignment Radiation Reduction Technique (DARRT).

    PubMed

    Khater, Nazih; Shen, Jim; Arenas, Javier; Keheila, Mohamed; Alsyouf, Muhannad; Martin, Jacob A; Lightfoot, Michelle A; Li, Roger; Olgin, Gaudencio; Smith, Jason C; Baldwin, D Duane

    2016-11-01

    Traditional techniques for obtaining percutaneous renal access utilize continuous fluoroscopy. In an attempt to minimize radiation exposure, we describe a novel laser direct alignment radiation reduction technique (DARRT) for percutaneous access and test it in a bench-top model. In this randomized-controlled bench-top study, 20 medical personnel obtained renal accesses using both the conventional bullseye technique and the laser DARRT. The primary endpoint was total fluoroscopy time. Secondary endpoints included insertion time, puncture attempts, course corrections, and subjective procedural difficulty. In the laser DARRT, fluoroscopy was used with the C-arm positioned with the laser beam at a 30° angle. The access needle and hub were aligned with the laser beam. Effective caliceal puncture was confirmed with fluoroscopy and direct vision. The Paired samples Wilcoxon signed rank test was used for statistical analysis with significance at p < 0.05. A total of 120 needle placements were recorded. Fluoroscopy time for needle access using the laser DARRT was significantly lower than the bullseye technique in all groups as follows: attendings (7.09 vs 18.51 seconds; p < 0.001), residents (6.55 vs 13.93 seconds; p = 0.001), and medical students (6.69 vs 20.22 seconds; p < 0.001). Students rated the laser DARRT easier to use (2.56 vs 4.89; p < 0.001). No difference was seen in total access time, puncture attempts, or course corrections between techniques. The laser DARRT reduced fluoroscopy time by 63%, compared with the conventional bullseye technique. The least experienced users found the laser DARRT significantly easier to learn. This novel technique is promising and merits additional testing in animal and human models.

  17. Biomechanical advantages of robot-assisted pedicle screw fixation in posterior lumbar interbody fusion compared with freehand technique in a prospective randomized controlled trial-perspective for patient-specific finite element analysis.

    PubMed

    Kim, Ho-Joong; Kang, Kyoung-Tak; Park, Sung-Cheol; Kwon, Oh-Hyo; Son, Juhyun; Chang, Bong-Soon; Lee, Choon-Ki; Yeom, Jin S; Lenke, Lawrence G

    2017-05-01

    There have been conflicting results on the surgical outcome of lumbar fusion surgery using two different techniques: robot-assisted pedicle screw fixation and conventional freehand technique. In addition, there have been no studies about the biomechanical issues between both techniques. This study aimed to investigate the biomechanical properties in terms of stress at adjacent segments using robot-assisted pedicle screw insertion technique (robot-assisted, minimally invasive posterior lumbar interbody fusion, Rom-PLIF) and freehand technique (conventional, freehand, open approach, posterior lumbar interbody fusion, Cop-PLIF) for instrumented lumbar fusion surgery. This is an additional post-hoc analysis for patient-specific finite element (FE) model. The sample is composed of patients with degenerative lumbar disease. Intradiscal pressure and facet contact force are the outcome measures. Patients were randomly assigned to undergo an instrumented PLIF procedure using a Rom-PLIF (37 patients) or a Cop-PLIF (41), respectively. Five patients in each group were selected using a simple random sampling method after operation, and 10 preoperative and postoperative lumbar spines were modeled from preoperative high-resolution computed tomography of 10 patients using the same method for a validated lumbar spine model. Under four pure moments of 7.5 Nm, the changes in intradiscal pressure and facet joint contact force at the proximal adjacent segment following fusion surgery were analyzed and compared with preoperative states. The representativeness of random samples was verified. Both groups showed significant increases in postoperative intradiscal pressure at the proximal adjacent segment under four moments, compared with the preoperative state. The Cop-PLIF models demonstrated significantly higher percent increments of intradiscal pressure at proximal adjacent segments under extension, lateral bending, and torsion moments than the Rom-PLIF models (p=.032, p=.008, and p=.016, respectively). Furthermore, the percent increment of facet contact force was significantly higher in the Cop-PLIF models under extension and torsion moments than in the Rom-PLIF models (p=.016 under both extension and torsion moments). The present study showed the clinical application of subject-specific FE analysis in the spine. Even though there was biomechanical superiority of the robot-assisted insertions in terms of alleviation of stress increments at adjacent segments after fusion, cautious interpretation is needed because of the small sample size. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Infrared spectroscopy and upconversion luminescence behaviour of erbium doped yttrium (III) oxide phosphor

    NASA Astrophysics Data System (ADS)

    Dubey, Vikas; Tiwari, Ratnesh; Tamrakar, Raunak Kumar; Rathore, Gajendra Singh; Sharma, Chitrakant; Tiwari, Neha

    2014-11-01

    The paper reports upconversion luminescence behaviour and infra-red spectroscopic pattern of erbium doped yttrium (III) oxide phosphor. Sample was synthesized by solid state reaction method with variable concentration or erbium (0.5-2.5 mol%). The conventional solid state method is suitable for large scale production and eco-friendly method. The prepared sample was characterized by X-ray diffraction (XRD) technique. From structural analysis by XRD technique shows cubic structure of prepared sample with variable concentration of erbium and no impurity phase were found when increase the concentration of Er3+. Particle size was calculated by Scherer's formula and it varies from 67 nm to 120 nm. The surface morphology of prepared phosphor was determined by field emission gun scanning electron microscopy (FEGSEM) technique. The surface morphology of the sample shows good connectivity with grains as well as some agglomerates formation occurs in sample. The functional group analysis was done by Fourier transform infra-red technique (FTIR) analysis which confirm the formation of Y2O3:Er3+ phosphor was prepared. The results indicated that the Y2O3:Er3+ phosphors might have high upconversion efficiency because of their low vibrational energy. Under 980 nm laser excitation sample shows intense green emission at 555 nm and orange emission at 590 nm wavelength. For green emission transition occurs 2H11/2 → 4I15/2, 4S3/2 → 4I15/2 for upconversion emissions. Excited state absorption and energy transfer process were discussed as possible upconversion mechanisms. The near infrared luminescence spectra was recorded. The upconversion luminescence intensity increase with increasing the concentration or erbium up to 2 mol% after that luminescence intensity decreases due to concentration quenching occurs. Spectrophotometric determinations of peaks are evaluated by Commission Internationale de I'Eclairage (CIE) technique. From CIE technique the dominant peak of from PL spectra shows intense green emission so the prepared phosphor is may be useful for green light emitting diode (GLED) application.

  19. Practical Framework for an Electron Beam Induced Current Technique Based on a Numerical Optimization Approach

    NASA Astrophysics Data System (ADS)

    Yamaguchi, Hideshi; Soeda, Takeshi

    2015-03-01

    A practical framework for an electron beam induced current (EBIC) technique has been established for conductive materials based on a numerical optimization approach. Although the conventional EBIC technique is useful for evaluating the distributions of dopants or crystal defects in semiconductor transistors, issues related to the reproducibility and quantitative capability of measurements using this technique persist. For instance, it is difficult to acquire high-quality EBIC images throughout continuous tests due to variation in operator skill or test environment. Recently, due to the evaluation of EBIC equipment performance and the numerical optimization of equipment items, the constant acquisition of high contrast images has become possible, improving the reproducibility as well as yield regardless of operator skill or test environment. The technique proposed herein is even more sensitive and quantitative than scanning probe microscopy, an imaging technique that can possibly damage the sample. The new technique is expected to benefit the electrical evaluation of fragile or soft materials along with LSI materials.

  20. Constraint-Induced Therapy Combined with Conventional Neurorehabilitation Techniques in Chronic Stroke Patients with Plegic Hands: A Case Series

    PubMed Central

    Taub, Edward; Uswatte, Gitendra; Bowman, Mary H.; Mark, Victor W.; Delgado, Adriana; Bryson, Camille; Morris, David; Bishop-McKay, Staci

    2012-01-01

    Objective To determine in this pilot study whether the combination of CI therapy and conventional rehabilitation techniques can produce meaningful motor improvement in chronic stroke patients with initially fisted hands. In the past, limited success has been achieved using CI therapy alone for stroke patients with plegic hands. Design Case series Setting University hospital outpatient laboratory Participants Consecutive sample of 6 patients > 1 yr post-stroke with plegic hands Interventions Treatment consisted of an initial period of 3 weeks (Phase A) when adaptive equipment in the home, orthotics and splints were employed to improve ability to engage in activities of daily living. This was continued in Phase B, when CI therapy along with selected neurodevelopmental treatment techniques were added. Main Outcome Measures Motor Activity Log (MAL), accelerometry, Fugl-Meyer Motor Assessment (F-M) Results Patients exhibited a large improvement in spontaneous real-world use of the more-affected arm (mean lower-functioning MAL change = 1.3±0.4 points, P <0.001, d′ = 3.0), and a similar pattern of increase in an objective measure of real-world more-affected arm movement (mean change in ratio of more- to less-affected arm accelerometer recordings = 0.12±0.1 points, P = 0.016 d′ = 1.2). A large improvement in motor status was also recorded (mean F-M change = 5.3±3.3 points, P = 0.005, d′ = 1.6). Conclusions The findings of this pilot study suggest that stroke patients with plegic hands can benefit from CI therapy combined with some conventional rehabilitation techniques, even long after brain injury. More research is warranted. PMID:22922823

  1. Permeability evaluation after decay removal in primary teeth with current caries-excavation techniques.

    PubMed

    Shabzendedar, Mahbobeh; Moosavi, Horieh; Talbi, Maryam; Sharifi, Marjan

    2011-11-01

    The goal of the study was to evaluate the effect of caries removal by three various methods on the permeability of class II composite resin restorations in primary molar teeth. Forty-five recently extracted primary molars were randomly assigned to three groups for three different methods of caries removal; group 1-mechanical, group 2-caries detector dye, and group 3-Carisolv (n = 15). After that, class II cavities in all groups were restored with the adhesive (Opti Bond Solo Plus) that was applied according to the manufacturer's instruction and a posterior composite (Herculite XRV), which was used incrementally. After 24 hours the samples were thermocycled in water for 500 cycles between 5 and 55°C with a dwell time of 30 sec. Permeability was assessed by the fluid filtration method. The data were analyzed using the ANOVA test while study groups were compared with Tukey test for statistically significant differences at a 5% significance level. The evaluation of tested groups indicated that the highest (0.80) and least (0.37) mean of permeability was observed in group 2 and 3 respectively. Significant difference was revealed among the tested groups (p = 0.045). The comparison of Carisolv and caries detector dye groups indicated a statistically significant difference (p = 0.037). There was not any significant difference between Carisolv or caries dye in the conventional group. Using the chemomechanical and staining methods for caries removal had no more detrimental effect on permeability than the conventional technique. However, caries detection dye for caries removal could be more harmful than chemomechanical method. None of the current caries-excavation techniques could eliminate permeability in class II composite resin restorations. Furthermore, staining methods do not have an adverse effect on sealing ability in comparison to the conventional technique.

  2. Demosaiced pixel super-resolution in digital holography for multiplexed computational color imaging on-a-chip (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Wu, Yichen; Zhang, Yibo; Luo, Wei; Ozcan, Aydogan

    2017-03-01

    Digital holographic on-chip microscopy achieves large space-bandwidth-products (e.g., >1 billion) by making use of pixel super-resolution techniques. To synthesize a digital holographic color image, one can take three sets of holograms representing the red (R), green (G) and blue (B) parts of the spectrum and digitally combine them to synthesize a color image. The data acquisition efficiency of this sequential illumination process can be improved by 3-fold using wavelength-multiplexed R, G and B illumination that simultaneously illuminates the sample, and using a Bayer color image sensor with known or calibrated transmission spectra to digitally demultiplex these three wavelength channels. This demultiplexing step is conventionally used with interpolation-based Bayer demosaicing methods. However, because the pixels of different color channels on a Bayer image sensor chip are not at the same physical location, conventional interpolation-based demosaicing process generates strong color artifacts, especially at rapidly oscillating hologram fringes, which become even more pronounced through digital wave propagation and phase retrieval processes. Here, we demonstrate that by merging the pixel super-resolution framework into the demultiplexing process, such color artifacts can be greatly suppressed. This novel technique, termed demosaiced pixel super-resolution (D-PSR) for digital holographic imaging, achieves very similar color imaging performance compared to conventional sequential R,G,B illumination, with 3-fold improvement in image acquisition time and data-efficiency. We successfully demonstrated the color imaging performance of this approach by imaging stained Pap smears. The D-PSR technique is broadly applicable to high-throughput, high-resolution digital holographic color microscopy techniques that can be used in resource-limited-settings and point-of-care offices.

  3. Microstructures and Mechanical Properties of Commercially Pure Ti Processed by Rotationally Accelerated Shot Peening

    PubMed Central

    Huang, Zhaowen; Cao, Yang; Nie, Jinfeng; Zhou, Hao; Li, Yusheng

    2018-01-01

    Gradient structured materials possess good combinations of strength and ductility, rendering the materials attractive in industrial applications. In this research, a surface nanocrystallization (SNC) technique, rotationally accelerated shot peening (RASP), was employed to produce a gradient nanostructured pure Ti with a deformation layer that had a thickness of 2000 μm, which is thicker than those processed by conventional SNC techniques. It is possible to fabricate a gradient structured Ti workpiece without delamination. Moreover, based on the microstructural features, the microstructure of the processed sample can be classified into three regions, from the center to the surface of the RASP-processed sample: (1) a twinning-dominated core region; (2) a “twin intersection”-dominated twin transition region; and (3) the nanostructured region, featuring nanograins. A microhardness gradient was detected from the RASP-processed Ti. The surface hardness was more than twice that of the annealed Ti sample. The RASP-processed Ti sample exhibited a good combination of yield strength and uniform elongation, which may be attributed to the high density of deformation twins and a strong back stress effect. PMID:29498631

  4. Conventional and conformal technique of external beam radiotherapy in locally advanced cervical cancer: Dose distribution, tumor response, and side effects

    NASA Astrophysics Data System (ADS)

    Mutrikah, N.; Winarno, H.; Amalia, T.; Djakaria, M.

    2017-08-01

    The objective of this study was to compare conventional and conformal techniques of external beam radiotherapy (EBRT) in terms of the dose distribution, tumor response, and side effects in the treatment of locally advanced cervical cancer patients. A retrospective cohort study was conducted on cervical cancer patients who underwent EBRT before brachytherapy in the Radiotherapy Department of Cipto Mangunkusumo Hospital. The prescribed dose distribution, tumor response, and acute side effects of EBRT using conventional and conformal techniques were investigated. In total, 51 patients who underwent EBRT using conventional techniques (25 cases using Cobalt-60 and 26 cases using a linear accelerator (LINAC)) and 29 patients who underwent EBRT using conformal techniques were included in the study. The distribution of the prescribed dose in the target had an impact on the patient’s final response to EBRT. The complete response rate of patients to conformal techniques was significantly greater (58%) than that of patients to conventional techniques (42%). No severe acute local side effects were seen in any of the patients (Radiation Therapy Oncology Group (RTOG) grades 3-4). The distribution of the dose and volume to the gastrointestinal tract affected the proportion of mild acute side effects (RTOG grades 1-2). The urinary bladder was significantly greater using conventional techniques (Cobalt-60/LINAC) than using conformal techniques at 72% and 78% compared to 28% and 22%, respectively. The use of conformal techniques in pelvic radiation therapy is suggested in radiotherapy centers with CT simulators and 3D Radiotherapy Treatment Planning Systems (RTPSs) to decrease some uncertainties in radiotherapy planning. The use of AP/PA pelvic radiation techniques with Cobalt-60 should be limited in body thicknesses equal to or less than 18 cm. When using conformal techniques, delineation should be applied in the small bowel, as it is considered a critical organ according to RTOG consensus guidelines.

  5. Use of a wave reverberation technique to infer the density compression of shocked liquid deuterium to 75 GPa.

    PubMed

    Knudson, M D; Hanson, D L; Bailey, J E; Hall, C A; Asay, J R

    2003-01-24

    A novel approach was developed to probe density compression of liquid deuterium (L-D2) along the principal Hugoniot. Relative transit times of shock waves reverberating within the sample are shown to be sensitive to the compression due to the first shock. This technique has proven to be more sensitive than the conventional method of inferring density from the shock and mass velocity, at least in this high-pressure regime. Results in the range of 22-75 GPa indicate an approximately fourfold density compression, and provide data to differentiate between proposed theories for hydrogen and its isotopes.

  6. The tropospheric distribution of formaldehyde

    NASA Astrophysics Data System (ADS)

    Lowe, D. C.; Schmidt, U.; Ehhalt, D. H.

    1981-12-01

    A measurement technique for determining the very low formaldehyde concentrations in clean air is described. The method is based on the standard derivation of formaldehyde with 2,4-dinitrophenylhydrazine. The derivative is separated, using high performance liquid chromatography, and detected at 254 nm with a conventional UV absorption detector. The sampling and analysis technique was used to measure tropospheric mixing ratios at various places in Europe and New Zealand as well as during a cruise in the North and South Atlantic. The results of the measurements show that formaldehyde mixing ratios in clean air are very low. In clean maritime air no significant difference in the formaldehyde mixing ratio between the hemispheres is observed.

  7. Simultaneous measurement of temperature and strain using four connecting wires

    NASA Technical Reports Server (NTRS)

    Parker, Allen R., Jr.

    1993-01-01

    This paper describes a new signal-conditioning technique for measuring strain and temperature which uses fewer connecting wires than conventional techniques. Simultaneous measurement of temperature and strain has been achieved by using thermocouple wire to connect strain gages to signal conditioning. This signal conditioning uses a new method for demultiplexing sampled analog signals and the Anderson current loop circuit. Theory is presented along with data to confirm that strain gage resistance change is sensed without appreciable error because of thermoelectric effects. Furthermore, temperature is sensed without appreciable error because of voltage drops caused by strain gage excitation current flowing through the gage resistance.

  8. Compressed sensing system considerations for ECG and EMG wireless biosensors.

    PubMed

    Dixon, Anna M R; Allstot, Emily G; Gangopadhyay, Daibashish; Allstot, David J

    2012-04-01

    Compressed sensing (CS) is an emerging signal processing paradigm that enables sub-Nyquist processing of sparse signals such as electrocardiogram (ECG) and electromyogram (EMG) biosignals. Consequently, it can be applied to biosignal acquisition systems to reduce the data rate to realize ultra-low-power performance. CS is compared to conventional and adaptive sampling techniques and several system-level design considerations are presented for CS acquisition systems including sparsity and compression limits, thresholding techniques, encoder bit-precision requirements, and signal recovery algorithms. Simulation studies show that compression factors greater than 16X are achievable for ECG and EMG signals with signal-to-quantization noise ratios greater than 60 dB.

  9. Sample flow switching techniques on microfluidic chips.

    PubMed

    Pan, Yu-Jen; Lin, Jin-Jie; Luo, Win-Jet; Yang, Ruey-Jen

    2006-02-15

    This paper presents an experimental investigation into electrokinetically focused flow injection for bio-analytical applications. A novel microfluidic device for microfluidic sample handling is presented. The microfluidic chip is fabricated on glass substrates using conventional photolithographic and chemical etching processes and is bonded using a high-temperature fusion method. The proposed valve-less device is capable not only of directing a single sample flow to a specified output port, but also of driving multiple samples to separate outlet channels or even to a single outlet to facilitate sample mixing. The experimental results confirm that the sample flow can be electrokinetically pre-focused into a narrow stream and guided to the desired outlet port by means of a simple control voltage model. The microchip presented within this paper has considerable potential for use in a variety of applications, including high-throughput chemical analysis, cell fusion, fraction collection, sample mixing, and many other applications within the micro-total-analysis systems field.

  10. Cost-effectiveness of liquid-based cytology with or without hybrid-capture II HPV test compared with conventional Pap smears: a study by the French Society of Clinical Cytology.

    PubMed

    Cochand-Priollet, Béatrix; Cartier, Isabelle; de Cremoux, Patricia; Le Galès, Catherine; Ziol, Marianne; Molinié, Vincent; Petitjean, Alain; Dosda, Anne; Merea, Estelle; Biaggi, Annonciade; Gouget, Isabelle; Arkwright, Sylviane; Vacher-Lavenu, Marie-Cécile; Vielh, Philippe; Coste, Joël

    2005-11-01

    Many articles concerning conventional Pap smears, ThinPrep liquid-based cytology (LBC) and Hybrid-Capture II HPV test (HC II) have been published. This study, carried out by the French Society of Clinical Cytology, may be conspicuous for several reasons: it was financially independent; it compared the efficiency of the conventional Pap smear and LBC, of the conventional Pap smear and HC II, and included an economic study based on real costs; for all the women, a "gold standard" reference method, colposcopy, was available and biopsies were performed whenever a lesion was detected; The conventional Pap smear, the LBC (split-sample technique), the colposcopy, and the biopsies were done at the same time. This study included 2,585 women shared into two groups: a group A of a high-risk population, a group B of a screening population. The statistical analysis of the results showed that conventional Pap smears consistently had superior or equivalent sensitivity and specificity than LBC for the lesions at threshold CIN-I (Cervical Intraepithelial Neoplasia) or CIN-II or higher. It underlined the low specificity of the HC II. Finally, the LBC mean cost was never covered by the Social Security tariff.

  11. Measurements for the BETC in-situ combustion experiment. [Post test surveys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wayland, J.R.; Bartel, L.C.

    The Bartlesville Energy Technology Center (BETC) in situ combustion pilot project near Bartlette, Kansas, was studied using controlled source audio-magnetotelluric (CSAMT) mapping, thermal gravimetric analysis (TGA), conventional geophysical logging and modeling of the fireflood. Measurements of formation resistivity changes induced by in situ combustion indicate that CSAMT resistivity maps should show an increase in apparent resistivity. The substantial decrease of apparent resistivity measured within the five spot pattern indicated a complex sequence of events. Using the results from the CSAMT surveys the fire front was located and posttest core samples were obtained. The posttest core samples were examined using TGAmore » techniques, and using information from combustion tube runs as standards, the location of the fire front in the core samples from the posttest holes was inferred. Models of the reservoir in situ combustion process were developed to help analyze the field results. The combustion kinematics, when used in conjunction with CSAMT and TGA techniques, indicated that considerable bypass of injected air occurred with an influx of brine into previously burned zones. This experiment offered an opportunity to integrate several new techniques into a systematic study of a difficult problem.« less

  12. A rapid method for the simultaneous determination of gross alpha and beta activities in water samples using a low background liquid scintillation counter.

    PubMed

    Sanchez-Cabeza, J A; Pujol, L

    1995-05-01

    The radiological examination of water requires a rapid screening technique that permits the determination of the gross alpha and beta activities of each sample in order to decide if further radiological analyses are necessary. In this work, the use of a low background liquid scintillation system (Quantulus 1220) is proposed to simultaneously determine the gross activities in water samples. Liquid scintillation is compared to more conventional techniques used in most monitoring laboratories. In order to determine the best counting configuration of the system, pulse shape discrimination was optimized for 6 scintillant/vial combinations. It was concluded that the best counting configuration was obtained with the scintillation cocktail Optiphase Hisafe 3 in Zinsser low diffusion vials. The detection limits achieved were 0.012 Bq L-1 and 0.14 Bq L-1 for gross alpha and beta activity respectively, after a 1:10 concentration process by simple evaporation and for a counting time of only 360 min. The proposed technique is rapid, gives spectral information, and is adequate to determine gross activities according to the World Health Organization (WHO) guideline values.

  13. Optimization of ultrahigh-speed multiplex PCR for forensic analysis.

    PubMed

    Gibson-Daw, Georgiana; Crenshaw, Karin; McCord, Bruce

    2018-01-01

    In this paper, we demonstrate the design and optimization of an ultrafast PCR amplification technique, used with a seven-locus multiplex that is compatible with conventional capillary electrophoresis systems as well as newer microfluidic chip devices. The procedure involves the use of a high-speed polymerase and a rapid cycling protocol to permit multiplex PCR amplification of forensic short tandem repeat loci in 6.5 min. We describe the selection and optimization of master mix reagents such as enzyme, buffer, MgCl 2 , and dNTPs, as well as primer ratios, total volume, and cycle conditions, in order to get the best profile in the shortest time possible. Sensitivity and reproducibility studies are also described. The amplification process utilizes a small high-speed thermocycler and compact laptop, making it portable and potentially useful for rapid, inexpensive on-site genotyping. The seven loci of the multiplex were taken from conventional STR genotyping kits and selected for their size and lack of overlap. Analysis was performed using conventional capillary electrophoresis and microfluidics with fluorescent detection. Overall, this technique provides a more rapid method for rapid sample screening of suspects and victims. Graphical abstract Rapid amplification of forensic DNA using high speed thermal cycling followed by capillary or microfluidic electrophoresis.

  14. The Effect of Simplifying Dental Implant Drilling Sequence on Osseointegration: An Experimental Study in Dogs

    PubMed Central

    Giro, Gabriela; Tovar, Nick; Marin, Charles; Bonfante, Estevam A.; Jimbo, Ryo; Suzuki, Marcelo; Janal, Malvin N.; Coelho, Paulo G.

    2013-01-01

    Objectives. To test the hypothesis that there would be no differences in osseointegration by reducing the number of drills for site preparation relative to conventional drilling sequence. Methods. Seventy-two implants were bilaterally placed in the tibia of 18 beagle dogs and remained for 1, 3, and 5 weeks. Thirty-six implants were 3.75 mm in diameter and the other 36 were 4.2 mm. Half of the implants of each diameter were placed under a simplified technique (pilot drill + final diameter drill) and the other half were placed under conventional drilling where multiple drills of increasing diameter were utilized. After euthanisation, the bone-implant samples were processed and referred to histological analysis. Bone-to-implant contact (BIC) and bone-area-fraction occupancy (BAFO) were assessed. Statistical analyses were performed by GLM ANOVA at 95% level of significance considering implant diameter, time in vivo, and drilling procedure as independent variables and BIC and BAFO as the dependent variables. Results. Both techniques led to implant integration. No differences in BIC and BAFO were observed between drilling procedures as time elapsed in vivo. Conclusions. The simplified drilling protocol presented comparable osseointegration outcomes to the conventional protocol, which proved the initial hypothesis. PMID:23431303

  15. Ocular Biocompatibility of Nitinol Intraocular Clips

    PubMed Central

    Velez-Montoya, Raul; Erlanger, Michael

    2012-01-01

    Purpose. To evaluate the tolerance and biocompatibility of a preformed nitinol intraocular clip in an animal model after anterior segment surgery. Methods. Yucatan mini-pigs were used. A 30-gauge prototype injector was used to attach a shape memory nitinol clip to the iris of five pigs. Another five eyes received conventional polypropylene suture with a modified Seipser slip knot. The authors compared the surgical time of each technique. All eyes underwent standard full-field electroretinogram at baseline and 8 weeks after surgery. The animals were euthanized and eyes collected for histologic analysis after 70 days (10 weeks) postsurgery. The corneal thickness, corneal endothelial cell counts, specular microscopy parameters, retina cell counts, and electroretinogram parameters were compared between the groups. A two sample t-test for means and a P value of 0.05 were use for assessing statistical differences between measurements. Results. The injection of the nitinol clip was 15 times faster than conventional suturing. There were no statistical differences between the groups for corneal thickness, endothelial cell counts, specular microscopy parameters, retina cell counts, and electroretinogram measurements. Conclusions. The nitinol clip prototype is well tolerated and showed no evidence of toxicity in the short-term. The injectable delivery system was faster and technically less challenging than conventional suture techniques. PMID:22064995

  16. Resolution enhancement in MR spectroscopy of red bone marrow fat via intermolecular double-quantum coherences

    NASA Astrophysics Data System (ADS)

    Bao, Jianfeng; Cui, Xiaohong; Huang, Yuqing; Zhong, Jianhui; Chen, Zhong

    2015-08-01

    High-resolution 1H magnetic resonance spectroscopy (MRS) is generally inaccessible in red bone marrow (RBM) tissues using conventional MRS techniques. This is because signal from these tissues suffers from severe inhomogeneity in the main static B0 field originated from the intrinsic honeycomb structures in trabecular bone. One way to reduce effects of B0 field inhomogeneity is by using the intermolecular double quantum coherence (iDQC) technique, which has been shown in other systems to obtain signals insensitive to B0 field inhomogeneity. In the present study, we employed an iDQC approach to enhance the spectral resolution of RBM. The feasibility and performance of this method for achieving high resolution MRS was verified by experiments on phantoms and pig vertebral bone samples. Unsaturated fatty acid peaks which overlap in the conventional MRS were well resolved and identified in the iDQC spectrum. Quantitative comparison of fractions of three types of fatty acids was performed between iDQC spectra on the in situ RMB and conventional MRS on the extracted fat from the same RBM. Observations of unsaturated fatty acids with iDQC MRS may provide valuable information and may hold potential in diagnosis of diseases such as obesity, diabetes, and leukemia.

  17. Optical properties of (50-X)BaO-X(YF2)-50P2O5 glasses

    NASA Astrophysics Data System (ADS)

    Narayanan, Manoj Kumar; Shashikala, H. D.

    2018-05-01

    Glasses with composition (50-X)BaO-X(YF2)-50P2O5 (Y - Ca, Ba, X = 0, 10, 20 mol%) were prepared using conventional melt-quenching technique. Optical parameters of prepared samples such as optical band gap energy increased, while Urbach energy and refractive index decreased with partial substitution of BaO with CaF2 or BaF2 in the glass batch.

  18. Adaptive optical microscope for brain imaging in vivo

    NASA Astrophysics Data System (ADS)

    Wang, Kai

    2017-04-01

    The optical heterogeneity of biological tissue imposes a major limitation to acquire detailed structural and functional information deep in the biological specimens using conventional microscopes. To restore optimal imaging performance, we developed an adaptive optical microscope based on direct wavefront sensing technique. This microscope can reliably measure and correct biological samples induced aberration. We demonstrated its performance and application in structural and functional brain imaging in various animal models, including fruit fly, zebrafish and mouse.

  19. A synchrotron-based local computed tomography combined with data-constrained modelling approach for quantitative analysis of anthracite coal microstructure

    PubMed Central

    Chen, Wen Hao; Yang, Sam Y. S.; Xiao, Ti Qiao; Mayo, Sherry C.; Wang, Yu Dan; Wang, Hai Peng

    2014-01-01

    Quantifying three-dimensional spatial distributions of pores and material compositions in samples is a key materials characterization challenge, particularly in samples where compositions are distributed across a range of length scales, and where such compositions have similar X-ray absorption properties, such as in coal. Consequently, obtaining detailed information within sub-regions of a multi-length-scale sample by conventional approaches may not provide the resolution and level of detail one might desire. Herein, an approach for quantitative high-definition determination of material compositions from X-ray local computed tomography combined with a data-constrained modelling method is proposed. The approach is capable of dramatically improving the spatial resolution and enabling finer details within a region of interest of a sample larger than the field of view to be revealed than by using conventional techniques. A coal sample containing distributions of porosity and several mineral compositions is employed to demonstrate the approach. The optimal experimental parameters are pre-analyzed. The quantitative results demonstrated that the approach can reveal significantly finer details of compositional distributions in the sample region of interest. The elevated spatial resolution is crucial for coal-bed methane reservoir evaluation and understanding the transformation of the minerals during coal processing. The method is generic and can be applied for three-dimensional compositional characterization of other materials. PMID:24763649

  20. Robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis of randomized controlled trials.

    PubMed

    Gao, Shutao; Lv, Zhengtao; Fang, Huang

    2018-04-01

    Several studies have revealed that robot-assisted technique might improve the pedicle screw insertion accuracy, but owing to the limited sample sizes in the individual study reported up to now, whether or not robot-assisted technique is superior to conventional freehand technique is indefinite. Thus, we performed this systematic review and meta-analysis based on randomized controlled trials to assess which approach is better. Electronic databases including PubMed, EMBASE, CENTRAL, ISI Web of Science, CNKI and WanFang were systematically searched to identify potentially eligible articles. Main endpoints containing the accuracy of pedicle screw implantation and proximal facet joint violation were evaluated as risk ratio (RR) and the associated 95% confidence intervals (95% CIs), while radiation exposure and surgical duration were presented as mean difference (MD) or standard mean difference (SMD). Meta-analyses were performed using RevMan 5.3 software. Six studies involving 158 patients (688 pedicle screws) in robot-assisted group and 148 patients (672 pedicle screws) in freehand group were identified matching our study. The Grade A accuracy rate in robot-assisted group was superior to freehand group (RR 1.03, 95% CI 1.00, 1.06; P = 0.04), but the Grade A + B accuracy rate did not differ between the two groups (RR 1.01, 95% CI 0.99, 1.02; P = 0.29). With regard to proximal facet joint violation, the combined results suggested that robot-assisted group was associated with significantly fewer proximal facet joint violation than freehand group (RR 0.07, 95% CI 0.01, 0.55; P = 0.01). As was the radiation exposure, our findings suggested that robot-assisted technique could significantly reduce the intraoperative radiation time (MD - 12.38, 95% CI - 17.95, - 6.80; P < 0.0001) and radiation dosage (SMD - 0.64, 95% CI - 0.85, - 0.43; P < 0.00001). But the overall surgical duration was longer in robot-assisted group than conventional freehand group (MD 20.53, 95% CI 5.17, 35.90; P = 0.009). The robot-assisted technique was associated with equivalent accuracy rate of pedicle screw implantation, fewer proximal facet joint violation, less intraoperative radiation exposure but longer surgical duration than freehand technique. Powerful evidence relies on more randomized controlled trials with high quality and larger sample size in the future.

  1. An uncooked vegan diet shifts the profile of human fecal microflora: computerized analysis of direct stool sample gas-liquid chromatography profiles of bacterial cellular fatty acids.

    PubMed Central

    Peltonen, R; Ling, W H; Hänninen, O; Eerola, E

    1992-01-01

    The effect of an uncooked extreme vegan diet on fecal microflora was studied by direct stool sample gas-liquid chromatography (GLC) of bacterial cellular fatty acids and by quantitative bacterial culture by using classical microbiological techniques of isolation, identification, and enumeration of different bacterial species. Eighteen volunteers were divided randomly into two groups. The test group received an uncooked vegan diet for 1 month and a conventional diet of mixed Western type for the other month of the study. The control group consumed a conventional diet throughout the study period. Stool samples were collected. Bacterial cellular fatty acids were extracted directly from the stool samples and measured by GLC. Computerized analysis of the resulting fatty acid profiles was performed. Such a profile represents all bacterial cellular fatty acids in a sample and thus reflects its microflora and can be used to detect changes, differences, or similarities of bacterial flora between individual samples or sample groups. GLC profiles changed significantly in the test group after the induction and discontinuation of the vegan diet but not in the control group at any time, whereas quantitative bacterial culture did not detect any significant change in fecal bacteriology in either of the groups. The results suggest that an uncooked extreme vegan diet alters the fecal bacterial flora significantly when it is measured by direct stool sample GLC of bacterial fatty acids. PMID:1482187

  2. Investigation of recrystallization of amorphous trehalose through hot-humidity stage X-ray powder diffraction.

    PubMed

    Jójárt-Laczkovich, Orsolya; Katona, Gábor; Aigner, Zoltán; Szabó-Révész, Piroska

    2016-12-01

    The aim of this work was an investigation of the physical changes of the amorphous model material spray-dried trehalose through the use of various analytical techniques and to identify a suitable, rapid method able to quantify the changes. The crystallinity changes and recrystallization process of amorphous samples were investigated by hot-humidity stage X-ray powder diffractometry (HH-XRPD) with fresh samples, conventional X-ray powder diffractometry (XRPD) used stored samples and by differential scanning calorimetry (DSC). The data from the three methods were compared and the various forms of trehalose were analysed. HH-XRPD demonstrated that the recrystallization began at 40 and 60°C up to 45% RH and at 70°C up to 30% RH into dihydrate form. At 70°C up to 60% RH the anhydrous form of trehalose appeared too. Conventional XRPD results showed, that in the 28days stored samples the dihydrate form was detected at 40°C, 50% RH. Storage at 60°C, 40% RH resulted in the appearance of the anhydrous form and at 60°C, 50% RH both polymorphic forms were detected. By carrying out the DSC measurements at different temperatures the fraction of recrystallized trehalose dihydrate was detected. The recrystallization investigated by HH-XRPD and DSC followed Avrami kinetics, the calculated rate constants of isothermal crystallization (K) were same. Both HH-XRPD and conventional XRPD was suitable for the detection of the physical changes of the amorphous model material. DSC measurements showed similar results as HH-XRPD. Primarily HH-XRPD could be suggested for prediction, because the method is fast and every changes could be studied on one sample. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Diffusive gradients in thin-films (DGT) for in situ sampling of selected endocrine disrupting chemicals (EDCs) in waters.

    PubMed

    Chen, Wei; Pan, Suhong; Cheng, Hao; Sweetman, Andrew J; Zhang, Hao; Jones, Kevin C

    2018-06-15

    A passive water sampler based on the diffusive gradients in thin-films (DGT) technique was developed and tested for 3 groups of endocrine disrupting chemicals (EDCs, including oestrogens, alkyl-phenols and bisphenols). Three different resins (hydrophilic-lipophilic-balanced (HLB), XAD18 and Strata-XL-A (SXLA)) were investigated for their suitability as the binding phase for DGT devices. Laboratory tests across a range of pH (3.5-9.5), ionic strength (0.001-0.5 M) and dissolved organic matter concentration (0-20 mg L -1 ) showed HLB and XAD18-DGT devices were more stable compared to SXLA-DGT. HLB-DGT and XAD18-DGT accumulated test chemicals with time consistent with theoretical predictions, while SXLA-DGT accumulated reduced amounts of chemical. DGT performance was also compared in field deployments up to 28 days, alongside conventional active sampling at a wastewater treatment plant. Uptake was linear to the samplers over 18 days, and then began to plateau/decline, indicating the maximum deployment time in those conditions. Concentrations provided by the DGT samplers compared well with those provided by auto-samplers. DGT integrated concentrations over the deployment period in a way that grab-sampling cannot. The advantages of the DGT sampler over active sampling include: low cost, ease of simultaneous multi-site deployment, in situ analyte pre-concentration and reduction of matrix interferences compared with conventional methods. Compared to other passive sampler designs, DGT uptake is independent of flow rate and therefore allows direct derivation of field concentrations from measured compound diffusion coefficients. This passive DGT sampler therefore constitutes a viable and attractive alternative to conventional grab and active water sampling for routine monitoring of selected EDCs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. High Prevalence of Schistosoma japonicum Infection in Carabao from Samar Province, the Philippines: Implications for Transmission and Control

    PubMed Central

    Gordon, Catherine A.; Acosta, Luz P.; Gray, Darren J.; Olveda, Remigo M.; Jarilla, Blanca; Gobert, Geoffrey N.; Ross, Allen G.; McManus, Donald P.

    2012-01-01

    Schistosoma japonicum is endemic in the Philippines, China and Indonesia, and infects more than 40 mammalian host species, all of which can act as reservoirs of infection. In China, water buffaloes have been shown to be major reservoirs of human infection. However, in the Philippines, carabao have not been considered important reservoir hosts for S. japonicum due to the low prevalence and infection intensities reported, the only exception being a qPCR-based study indicating 51% of carabao were S. japonicum-positive. However, the low prevalence found for the same animals when using conventional copro-parasitological techniques means that there is still confusion about the role of carabao in the transmission of schistosomiasis japonicum. To address this inconsistency, and to shed light on the potential role of carabao in the transmission of S. japonicum in the Philippines, we undertook a pilot survey, collecting fecal samples from animals in Western Samar Province and we used a combination of molecular and copro-parasitological techniques to determine the prevalence and intensity of S. japonicum. We found a high prevalence of S. japonicum in the carabao using a validated real-time PCR (qPCR) and a copro-parasitological tool, the formalin-ethyl acetate sedimentation (FEA-SD) technique. A much lower prevalence of S. japonicum was recorded for the same fecal samples using conventional PCR, the Kato-Katz technique and miracidial hatching. These results suggest that, due to their low diagnostic sensitivity, traditional copro-parasitological techniques underestimate infection in carabao. The use of FEA-SD and qPCR provides a more accurate diagnosis. Based on these findings, the role of bovines in the transmission of S. japonicum appears to be more important in the Philippines than previously recognized, and this may have significant implications for the future control of schistosomiasis there, particularly as, in contrast with previous surveys, we found an unprecedented high prevalence of S. japonicum in humans. PMID:23029571

  5. Non-contact measurements of creep properties of niobium at 1985 °C

    NASA Astrophysics Data System (ADS)

    Lee, J.; Wall, J. J.; Rogers, J. R.; Rathz, T. J.; Choo, H.; Liaw, P. K.; Hyers, R. W.

    2015-01-01

    The stress exponent in the power-law creep of niobium at 1985 °C was measured by a non-contact technique using an electrostatic levitation facility at NASA MSFC. This method employs a distribution of stress to allow the stress exponent to be determined from each test, rather than from the curve fit through measurements from multiple samples that is required by conventional methods. The sample is deformed by the centripetal acceleration from the rapid rotation, and the deformed shapes are analyzed to determine the strain. Based on a mathematical proof, which revealed that the stress exponent was determined uniquely by the ratio of the polar to equatorial strains, a series of finite-element analyses with the models of different stress exponents were also performed to determine the stress exponent corresponding to the measured strain ratio. The stress exponent from the ESL experiment showed a good agreement with those from the literature and the conventional creep test.

  6. Application of polymerase chain reaction for detection of Vibrio parahaemolyticus associated with tropical seafoods and coastal environment.

    PubMed

    Dileep, V; Kumar, H S; Kumar, Y; Nishibuchi, M; Karunasagar, Indrani; Karunasagar, Iddya

    2003-01-01

    To study the incidence of Vibrio parahaemolyticus in seafoods, water and sediment by molecular techniques vs conventional microbiological methods. Of 86 samples analysed, 28 recorded positive for V. parahaemolyticus by conventional microbiological method, while 53 were positive by the toxR-targeted PCR, performed directly on enrichment broth lysates. While one sample of molluscan shellfish was positive for tdh gene, trh gene was detected in three enrichment broths of molluscan shellfish. Direct application of PCR to enrichment broths will be useful for the rapid and sensitive detection of potentially pathogenic strains of V. parahemolyticus in seafoods. Vibrio parahaemolyticus is an important human pathogen responsible for food-borne gastroenteritis world-wide. As, both pathogenic and non-pathogenic strains of V. parahaemolyticus exist in the seafood, application of PCR specific for the virulence genes (tdh & trh) will help in detection of pathogenic strains of V. parahaemolyticus and consequently reduce the risk of food-borne illness.

  7. Retention of denture bases fabricated by three different processing techniques – An in vivo study

    PubMed Central

    Chalapathi Kumar, V. H.; Surapaneni, Hemchand; Ravikiran, V.; Chandra, B. Sarat; Balusu, Srilatha; Reddy, V. Naveen

    2016-01-01

    Aim: Distortion due to Polymerization shrinkage compromises the retention. To evaluate the amount of retention of denture bases fabricated by conventional, anchorized, and injection molding polymerization techniques. Materials and Methods: Ten completely edentulous patients were selected, impressions were made, and master cast obtained was duplicated to fabricate denture bases by three polymerization techniques. Loop was attached to the finished denture bases to estimate the force required to dislodge them by retention apparatus. Readings were subjected to nonparametric Friedman two-way analysis of variance followed by Bonferroni correction methods and Wilcoxon matched-pairs signed-ranks test. Results: Denture bases fabricated by injection molding (3740 g), anchorized techniques (2913 g) recorded greater retention values than conventional technique (2468 g). Significant difference was seen between these techniques. Conclusions: Denture bases obtained by injection molding polymerization technique exhibited maximum retention, followed by anchorized technique, and least retention was seen in conventional molding technique. PMID:27382542

  8. Rope-based oral fluid sampling for early detection of classical swine fever in domestic pigs at group level.

    PubMed

    Dietze, Klaas; Tucakov, Anna; Engel, Tatjana; Wirtz, Sabine; Depner, Klaus; Globig, Anja; Kammerer, Robert; Mouchantat, Susan

    2017-01-05

    Non-invasive sampling techniques based on the analysis of oral fluid specimen have gained substantial importance in the field of swine herd management. Methodological advances have a focus on endemic viral diseases in commercial pig production. More recently, these approaches have been adapted to non-invasive sampling of wild boar for transboundary animal disease detection for which these effective population level sampling methods have not been available. In this study, a rope-in-a-bait based oral fluid sampling technique was tested to detect classical swine fever virus nucleic acid shedding from experimentally infected domestic pigs. Separated in two groups treated identically, the course of the infection was slightly differing in terms of onset of the clinical signs and levels of viral ribonucleic acid detection in the blood and oral fluid. The technique was capable of detecting classical swine fever virus nucleic acid as of day 7 post infection coinciding with the first detection in conventional oropharyngeal swab samples from some individual animals. Except for day 7 post infection in the "slower onset group", the chances of classical swine fever virus nucleic acid detection in ropes were identical or higher as compared to the individual sampling. With the provided evidence, non-invasive oral fluid sampling at group level can be considered as additional cost-effective detection tool in classical swine fever prevention and control strategies. The proposed methodology is of particular use in production systems with reduced access to veterinary services such as backyard or scavenging pig production where it can be integrated in feeding or baiting practices.

  9. Antigen recovery and preservation using the microwave irradiation of biological samples for transmission electron microscopy analysis.

    PubMed

    Aïoun, Josiane; Chat, Sophie; Bordat, Christian; Péchoux, Christine

    2013-01-01

    Most studies using microwave irradiation (MWI) for the preparation of tissue samples have reported an improvement in structural integrity. However, there have been few studies on the effect of microwave (MW) on antigen preservation during sample preparation prior to immunolocalization. This report documents our experience of specimen preparation using an automatic microwave apparatus to obtain antigen preservation and retrieval. We tested the effects of MW processing vs. conventional procedures on the morphology and antigenicity of two different tissues: the brain and mammary gland, whose chemical composition and anatomical organization are quite different. We chose to locate the transcription factor PPARβ/δ using immunocytochemistry on brain tissue sections from hamsters. Antigen retrieval protocols involving MWI were used to restore immunoreactivity. We also studied the efficiency of the ultrastructural immunolocalization of both PPARγ and caveolin-1 following MWI vs. conventional treatment, on mammary gland tissue from mice at 10 days of lactation. Our findings showed that the treatment of tissue samples with MWI, in the context of a process lasting just a few hours from fixation to immunolocalization, enabled similar, or even better, results than conventional protocols. The quantification of immunolabeling for cav-1 indicated an increase in density of up to three-fold in tissues processed in the microwave oven. Furthermore, MW treatment permitted the localization of PPARβ/δ in glutaraldehyde-fixed specimens, which was impossible in the absence of MWI. This study thus showed that techniques involving the use of microwaves could largely improve both ultrastructure and immunodetection. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Determination of Root Canal Cleanliness by Different Irrigation Methods and Morphometric Analysis of Apical Third.

    PubMed

    Seixas, Fábio Heredia; Estrela, Carlos; Bueno, Mike Reis; Sousa-Neto, Manoel Damião; Pécora, Jesus Djalma

    2015-06-01

    The aim of this study was to determine the root canal area before and after the instrumentation 1 mm short of the apical foramen by clinical and cone beam computed tomography (CBCT) methods, and to evaluate the cleanliness of the apical region in mesiodistal flattened teeth by using optical microscopy. Forty-two human single-canal mandibular incisors were instrumented using the Free Tip Preparation technique up to three, four or five instruments from the initial. Cone beam computed tomography scans were acquired of the samples before and after root canal preparation (RCP). Irrigation was performed by conventional or hydrodynamic means, using 2.5% sodium hypochlorite. The samples were prepared for observation under an optical microscope. Images were digitally obtained, analyzed and the results were submitted to statistical analysis (two-way ANOVA complemented by Bonferroni's post-test). There was no significant difference between the studied anatomical areas with both CBCT and clinical methods. There were no differences between irrigation methods. It was verified differences between instrumentation techniques. Instrumentation with four instruments from the initial instrument determined a significant increase in the contact area when compared to preparation with three instruments, but RCP with 5 instruments did not result in a better cleanliness. The analysis with CBCT was not capable to determine the precise shape of surgical apical area comparing to the clinical method. Both the conventional and hydrodynamic irrigation techniques were not able to promote root canals debris-free. The instruments action in root canal walls was proportional to the number of instruments used from the initial apical instrument.

  11. Development of a micromanipulation method for single cell isolation of prokaryotes and its application in food safety.

    PubMed

    Hohnadel, Marisa; Maumy, Myriam; Chollet, Renaud

    2018-01-01

    For nearly a century, conventional microbiological methods have been standard practice for detecting and identifying pathogens in food. Nevertheless, the microbiological safety of food has improved and various rapid methods have been developed to overcome the limitations of conventional methods. Alternative methods are expected to detect low cell numbers, since the presence in food of even a single cell of a pathogenic organism may be infectious. With respect to low population levels, the performance of a detection method is assessed by producing serial dilutions of a pure bacterial suspension to inoculate representative food matrices with highly diluted bacterial cells (fewer than 10 CFU/ml). The accuracy of data obtained by multiple dilution techniques is not certain and does not exclude some colonies arising from clumps of cells. Micromanipulation techniques to capture and isolate single cells from environmental samples were introduced more than 40 years ago. The main limitation of the current micromanipulation technique is still the low recovery rate for the growth of a single cell in culture medium. In this study, we describe a new single cell isolation method and demonstrate that it can be used successfully to grow various types of microorganism from picked individual cells. Tests with Gram-positive and Gram-negative organisms, including cocci, rods, aerobes, anaerobes, yeasts and molds showed growth recovery rates from 60% to 100% after micromanipulation. We also highlight the use of our method to evaluate and challenge the detection limits of standard detection methods in food samples contaminated by a single cell of Salmonella enterica.

  12. Measurement of Creep Properties of Ultra-High-Temperature Materials by a Novel Non-Contact Technique

    NASA Technical Reports Server (NTRS)

    Hyers, Robert W.; Lee, Jonghyun; Rogers, Jan R.; Liaw, Peter K.

    2007-01-01

    A non-contact technique for measuring the creep properties of materials has been developed and validated as part of a collaboration among the University of Massachusetts, NASA Marshall Space Flight Center Electrostatic Levitation Facility (ESL), and the University of Tennessee. This novel method has several advantages over conventional creep testing. The sample is deformed by the centripetal acceleration from the rapid rotation, and the deformed shapes are analyzed to determine the strain. Since there is no contact with grips, there is no theoretical maximum temperature and no concern about chemical compatibility. Materials may be tested at the service temperature even for extreme environments such as rocket nozzles, or above the service temperature for accelerated testing of materials for applications such as jet engines or turbopumps for liquid-fueled engines. The creep measurements have been demonstrated to 2400 C with niobium, while the test facility, the NASA MSFC ESL, has processed materials up to 3400 C. Furthermore, the ESL creep method employs a distribution of stress to determine the stress exponent from a single test, versus the many tests required by conventional methods. Determination of the stress exponent from the ESL creep tests requires very precise measurement of the surface shape of the deformed sample for comparison to deformations predicted by finite element models for different stress exponents. An error analysis shows that the stress exponent can be determined to about 1% accuracy with the current methods and apparatus. The creep properties of single-crystal niobium at 1985 C showed excellent agreement with conventional tests performed according to ASTM Standard E-139. Tests on other metals, ceramics, and composites relevant to rocket propulsion and turbine engines are underway.

  13. High resolution ID-ICP-MS certification of an estuary water reference material (LGC 6016) and analysis of matrix induced polyatomic interferences.

    PubMed

    Evans, P; Fairman, B

    2001-10-01

    Reliable trace metal analysis of environmental samples is dependent upon the availability of high accuracy, matrix reference standards. Here, we present Cd, Cu, Ni, Pb and Zn isotope dilution determination for an estuary water certified reference material (LGC 6016). This work highlights the need for high-accuracy techniques in the development of trace element CRMs rather than conventional inter-laboratory trials. Certification of the estuary water LGC6016 was initially determined from a consensus mean from 14 laboratories but this was found to be unsatisfactory due to the large discrepancies in the reported concentrations. The material was re-analysed using isotope dilution ICP-MS techniques. Pb and Cd were determined using a conventional quadrupole ICP-MS (Elan 5000). Cu, Zn and Ni were determined using a magnetic sector ICP-MS (Finnigan Element), which allowed significant polyatomic interferences to be overcome. Using the magnetic sector instrument, precise mass calibration to within 0.02 amu permitted identification of the interferences. Most interferences derived from the sample matrix. For example, the high Na content causes interferences on 63Cu, due to the formation of 40Ar23Na and 23Na2 16O1H, which in a conventional quadrupole instrument would relate to an erroneous increase in signal intensity by up to 20%. For each analyte a combined uncertainty calculation was performed following the Eurachem/GTAC and ISO guideline. For each element a combined uncertainty of 2-3% was found, which represents a 10-fold improvement compared to certification by inter-laboratory comparison. Analysis of the combined uncertainty budget indicates that the majority of systematic uncertainty derives from the instrumental isotope ratio measurements.

  14. A rapid method for estimation of Pu-isotopes in urine samples using high volume centrifuge.

    PubMed

    Kumar, Ranjeet; Rao, D D; Dubla, Rupali; Yadav, J R

    2017-07-01

    The conventional radio-analytical technique used for estimation of Pu-isotopes in urine samples involves anion exchange/TEVA column separation followed by alpha spectrometry. This sequence of analysis consumes nearly 3-4 days for completion. Many a times excreta analysis results are required urgently, particularly under repeat and incidental/emergency situations. Therefore, there is need to reduce the analysis time for the estimation of Pu-isotopes in bioassay samples. This paper gives the details of standardization of a rapid method for estimation of Pu-isotopes in urine samples using multi-purpose centrifuge, TEVA resin followed by alpha spectrometry. The rapid method involves oxidation of urine samples, co-precipitation of plutonium along with calcium phosphate followed by sample preparation using high volume centrifuge and separation of Pu using TEVA resin. Pu-fraction was electrodeposited and activity estimated using 236 Pu tracer recovery by alpha spectrometry. Ten routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 47-88% with a mean and standard deviation of 64.4% and 11.3% respectively. With this newly standardized technique, the whole analytical procedure is completed within 9h (one working day hour). Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Automated imaging of cellular spheroids with selective plane illumination microscopy on a chip (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Paiè, Petra; Bassi, Andrea; Bragheri, Francesca; Osellame, Roberto

    2017-02-01

    Selective plane illumination microscopy (SPIM) is an optical sectioning technique that allows imaging of biological samples at high spatio-temporal resolution. Standard SPIM devices require dedicated set-ups, complex sample preparation and accurate system alignment, thus limiting the automation of the technique, its accessibility and throughput. We present a millimeter-scaled optofluidic device that incorporates selective plane illumination and fully automatic sample delivery and scanning. To this end an integrated cylindrical lens and a three-dimensional fluidic network were fabricated by femtosecond laser micromachining into a single glass chip. This device can upgrade any standard fluorescence microscope to a SPIM system. We used SPIM on a CHIP to automatically scan biological samples under a conventional microscope, without the need of any motorized stage: tissue spheroids expressing fluorescent proteins were flowed in the microchannel at constant speed and their sections were acquired while passing through the light sheet. We demonstrate high-throughput imaging of the entire sample volume (with a rate of 30 samples/min), segmentation and quantification in thick (100-300 μm diameter) cellular spheroids. This optofluidic device gives access to SPIM analyses to non-expert end-users, opening the way to automatic and fast screening of a high number of samples at subcellular resolution.

  16. Side effects and complications of intraosseous anesthesia and conventional oral anesthesia.

    PubMed

    Peñarrocha-Oltra, David; Ata-Ali, Javier; Oltra-Moscardó, María-José; Peñarrocha-Diago, María; Peñarrocha, Miguel

    2012-05-01

    To analyze the side effects and complications following intraosseous anesthesia (IA), comparing them with those of the conventional oral anesthesia techniques. A simple-blind, prospective clinical study was carried out. Each patient underwent two anesthetic techniques: conventional (local infiltration and locoregional anesthetic block) and intraosseous, for respective dental operations. In order to allow comparison of IA versus conventional anesthesia, the two operations were similar and affected the same two teeth in opposite quadrants. Heart rate was recorded in all cases before injection of the anesthetic solution and again 30 seconds after injection. The complications observed after anesthetic administration were recorded. A total of 200 oral anesthetic procedures were carried out in 100 patients. Both IA and conventional anesthesia resulted in a significant increase in heart rate, though the increase was greater with the latter technique. Incidents were infrequent with either anesthetic technique, with no significant differences between them. Regarding the complications, there were significant differences in pain at the injection site, with more intense pain in the case of IA (x2=3.532, p=0.030, Φ2=0.02), while the limitation of oral aperture was more pronounced with conventional anesthesia (x2=5.128, p<0.05, Φ2=0.014). Post-anesthetic biting showed no significant differences (x2=4.082, p=0.121, Φ2=0.009). Both anesthetic techniques significantly increased heart rate, and IA caused comparatively more pain at the injection site, while limited oral aperture was more frequent with conventional anesthesia. Post-anesthetic biting showed no significant differences between the two techniques.

  17. Comparison of the CoaguChek XS handheld coagulation analyzer and conventional laboratory methods measuring international normalised ratio (INR) values during the time to therapeutic range after mechanical valve surgery.

    PubMed

    Bardakci, Hasmet; Altıntaş, Garip; Çiçek, Omer Faruk; Kervan, Umit; Yilmaz, Sevinc; Kaplan, Sadi; Birincioglu, Cemal Levent

    2013-05-01

    To compare the international normalised ratio (INR) value of patients evaluated using the CoaguChek XS versus conventional laboratory methods, in the period after open-heart surgery for mechanical valve replacement until a therapeutic range is achieved using vitamin K antagonists (VKA) together with low molecular weight heparin (LMWH). One hundred and five patients undergoing open-heart surgery for mechanical valve replacement were enrolled. Blood samples were collected from patients before surgery, and on the second and fifth postoperative days, simultaneously for both the point of care device and conventional laboratory techniques. Patients were administered VKA together with LMWH at therapeutic doses (enoxaparin 100 IU/kg twice daily) subcutaneously, until an effective range was achieved on approximately the fifth day after surgery. The mean INR values using the CoaguChek XS preoperatively and on the second and fifth days postoperatively were 1.20 (SD ± 0.09), 1.82 (SD ± 0.45), and 2.55 (SD ± 0.55), respectively. Corresponding results obtained using conventional laboratory techniques were 1.18 (SD ± 0.1), 1.81 (SD ± 0.43), and 2.51 (SD ± 0.58). The correlation coefficient was r = 0.77 preoperatively, r = 0.981 on postoperative day 2, and r = 0.983 on postoperative day 5. Results using the CoaguChek XS Handheld Coagulation Analyzer correlated strongly with conventional laboratory methods, in the bridging period between open-heart surgery for mechanical valve replacement and the achievement of a therapeutic range on warfarin and LMWH. © 2013 Wiley Periodicals, Inc.

  18. A Retrospective Comparison of Conventional versus Transverse Mini-Incision Technique for Carpal Tunnel Release

    PubMed Central

    Gülşen, İsmail; Ak, Hakan; Evcılı, Gökhan; Balbaloglu, Özlem; Sösüncü, Enver

    2013-01-01

    Background. In this retrospective study, we aimed to compare the results of two surgical techniques, conventional and transverse mini-incision. Materials and Methods. 95 patients were operated between 2011 and 2012 in Bitlis State Hospital. 50 patients were operated with conventional technique and 45 of them were operated with minimal transverse incision. Postoperative complications, incision site problems, and the time of starting to use their hands in daily activities were noted. Results. 95 patients were included in the study. The mean age was 48. 87 of them were female and 8 were male. There was no problem of incision site in both of the two surgical techniques. Only in one patient, anesthesia developed in minimal incision technique. The time of starting to use their hands in daily activities was 22,2 days and 17 days in conventional and minimal incision technique, respectively. Conclusion. Two surgical techniques did not show superiority to each other in terms of postoperative complications and incision site problems except the time of starting to use their hands in daily activities. PMID:24396607

  19. DGT Passive Sampling for Quantitative in Situ Measurements of Compounds from Household and Personal Care Products in Waters.

    PubMed

    Chen, Wei; Li, Yanying; Chen, Chang-Er; Sweetman, Andrew J; Zhang, Hao; Jones, Kevin C

    2017-11-21

    Widespread use of organic chemicals in household and personal care products (HPCPs) and their discharge into aquatic systems means reliable, robust techniques to monitor environmental concentrations are needed. The passive sampling approach of diffusive gradients in thin-films (DGT) is developed here and demonstrated to provide in situ quantitative and time-weighted average (TWA) measurement of these chemicals in waters. The novel technique is developed for HPCPs, including preservatives, antioxidants and disinfectants, by evaluating the performance of different binding agents. Ultrasonic extraction of binding gels in acetonitrile gave good and consistent recoveries for all test chemicals. Uptake by DGT with HLB (hydrophilic-lipophilic-balanced) as the binding agent was relatively independent of pH (3.5-9.5), ionic strength (0.001-0.1 M) and dissolved organic matter (0-20 mg L -1 ), making it suitable for applications across a wide range of environments. Deployment time and diffusion layer thickness dependence experiments confirmed DGT accumulated chemicals masses are consistent with theoretical predictions. The technique was further tested and applied in the influent and effluent of a wastewater treatment plant. Results were compared with conventional grab-sampling and 24-h-composited samples from autosamplers. DGT provided TWA concentrations over up to 18 days deployment, with minimal effects from biofouling or the diffusive boundary layer. The field application demonstrated advantages of the DGT technique: it gives in situ analyte preconcentration in a simple matrix, with more quantitative measurement of the HPCP analytes.

  20. Group investigation with scientific approach in mathematics learning

    NASA Astrophysics Data System (ADS)

    Indarti, D.; Mardiyana; Pramudya, I.

    2018-03-01

    The aim of this research is to find out the effect of learning model toward mathematics achievement. This research is quasi-experimental research. The population of research is all VII grade students of Karanganyar regency in the academic year of 2016/2017. The sample of this research was taken using stratified cluster random sampling technique. Data collection was done based on mathematics achievement test. The data analysis technique used one-way ANOVA following the normality test with liliefors method and homogeneity test with Bartlett method. The results of this research is the mathematics learning using Group Investigation learning model with scientific approach produces the better mathematics learning achievement than learning with conventional model on material of quadrilateral. Group Investigation learning model with scientific approach can be used by the teachers in mathematics learning, especially in the material of quadrilateral, which is can improve the mathematics achievement.

  1. Comparison of soil pollution concentrations determined using AAS and portable XRF techniques.

    PubMed

    Radu, Tanja; Diamond, Dermot

    2009-11-15

    Past mining activities in the area of Silvermines, Ireland, have resulted in heavily polluted soils. The possibility of spreading pollution to the surrounding areas through dust blow-offs poses a potential threat for the local communities. Conventional environmental soil and dust analysis techniques are very slow and laborious and consequently there is a need for fast and accurate analytical methods, which can provide real-time in situ pollution mapping. Laboratory-based aqua regia acid digestion of the soil samples collected in the area followed by the atomic absorption spectrophotometry (AAS) analysis confirmed very high pollution, especially by Pb, As, Cu, and Zn. In parallel, samples were analyzed using portable X-ray fluorescence radioisotope and miniature tube powered (XRF) NITON instruments and their performance was compared. Overall, the portable XRF instrument gave excellent correlation with the laboratory-based reference AAS method.

  2. Precise Manipulation and Patterning of Protein Crystals for Macromolecular Crystallography Using Surface Acoustic Waves.

    PubMed

    Guo, Feng; Zhou, Weijie; Li, Peng; Mao, Zhangming; Yennawar, Neela H; French, Jarrod B; Huang, Tony Jun

    2015-06-01

    Advances in modern X-ray sources and detector technology have made it possible for crystallographers to collect usable data on crystals of only a few micrometers or less in size. Despite these developments, sample handling techniques have significantly lagged behind and often prevent the full realization of current beamline capabilities. In order to address this shortcoming, a surface acoustic wave-based method for manipulating and patterning crystals is developed. This method, which does not damage the fragile protein crystals, can precisely manipulate and pattern micrometer and submicrometer-sized crystals for data collection and screening. The technique is robust, inexpensive, and easy to implement. This method not only promises to significantly increase efficiency and throughput of both conventional and serial crystallography experiments, but will also make it possible to collect data on samples that were previously intractable. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Overview of Brain Microdialysis

    PubMed Central

    Chefer, Vladimir I.; Thompson, Alexis C.; Zapata, Agustin; Shippenberg, Toni S.

    2010-01-01

    The technique of microdialysis enables sampling and collecting of small-molecular-weight substances from the interstitial space. It is a widely used method in neuroscience and is one of the few techniques available that permits quantification of neurotransmitters, peptides, and hormones in the behaving animal. More recently, it has been used in tissue preparations for quantification of neurotransmitter release. This unit provides a brief review of the history of microdialysis and its general application in the neurosciences. The authors review the theoretical principles underlying the microdialysis process, methods available for estimating extracellular concentration from dialysis samples (i.e., relative recovery), the various factors that affect the estimate of in vivo relative recovery, and the importance of determining in vivo relative recovery to data interpretation. Several areas of special note, including impact of tissue trauma on the interpretation of microdialysis results, are discussed. Step-by-step instructions for the planning and execution of conventional and quantitative microdialysis experiments are provided. PMID:19340812

  4. Photogrammetry of the three-dimensional shape and texture of a nanoscale particle using scanning electron microscopy and free software.

    PubMed

    Gontard, Lionel C; Schierholz, Roland; Yu, Shicheng; Cintas, Jesús; Dunin-Borkowski, Rafal E

    2016-10-01

    We apply photogrammetry in a scanning electron microscope (SEM) to study the three-dimensional shape and surface texture of a nanoscale LiTi2(PO4)3 particle. We highlight the fact that the technique can be applied non-invasively in any SEM using free software (freeware) and does not require special sample preparation. Three-dimensional information is obtained in the form of a surface mesh, with the texture of the sample stored as a separate two-dimensional image (referred to as a UV Map). The mesh can be used to measure parameters such as surface area, volume, moment of inertia and center of mass, while the UV map can be used to study the surface texture using conventional image processing techniques. We also illustrate the use of 3D printing to visualize the reconstructed model. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Design of Measurement Apparatus for Electromagnetic Shielding Effectiveness Using Flanged Double Ridged Waveguide

    NASA Astrophysics Data System (ADS)

    Kwon, Jong Hwa; Choi, Jae Ick; Yook, Jong Gwan

    In this paper, we design and manufacture a flanged double ridged waveguide with a tapered section as a sample holder for measuring the electromagnetic shielding effectiveness (SE) of planar material in broadband frequency ranges up to 10GHz. The proposed technique overcomes the limitations of the conventional ASTM D4935 test method at high frequencies. The simulation results for the designed sample holders agree well with the fabricated ones in consideration of the design specification of S11 < -20dB within the frequency range of 1-10GHz. To verify the proposed measurement apparatus, the measured SE data of the commercial shielding materials from 1 to 10GHz were indirectly compared with those obtained from the ASTM D4935 from 30MHz to 1GHz. We observed that the SE data obtained by using both experimental techniques agree with each other.

  6. Alcoholic extraction enables EPR analysis to characterize radiation-induced cellulosic signals in spices.

    PubMed

    Ahn, Jae-Jun; Sanyal, Bhaskar; Akram, Kashif; Kwon, Joong-Ho

    2014-11-19

    Different spices such as turmeric, oregano, and cinnamon were γ-irradiated at 1 and 10 kGy. The electron paramagnetic resonance (EPR) spectra of the nonirradiated samples were characterized by a single central signal (g = 2.006), the intensity of which was significantly enhanced upon irradiation. The EPR spectra of the irradiated spice samples were characterized by an additional triplet signal at g = 2.006 with a hyperfine coupling constant of 3 mT, associated with the cellulose radical. EPR analysis on various sample pretreatments in the irradiated spice samples demonstrated that the spectral features of the cellulose radical varied on the basis of the pretreatment protocol. Alcoholic extraction pretreatment produced considerable improvements of the EPR signals of the irradiated spice samples relative to the conventional oven and freeze-drying techniques. The alcoholic extraction process is therefore proposed as the most suitable sample pretreatment for unambiguous detection of irradiated spices by EPR spectroscopy.

  7. Determination of the band gap of indium-rich InGaN by means of photoacoustic spectroscopy

    NASA Astrophysics Data System (ADS)

    Oliva, Robert; Zelewski, Szymon J.; Janicki, Łukasz; Gwóźdź, Katarzyna R.; Serafińczuk, Jarosław; Rudziński, Mariusz; Özbay, Ekmel; Kudrawiec, Robert

    2018-03-01

    Photoacoustic (PA) measurements have been performed on a series of In x Ga1-x N thin films grown with x > 50%. In order to illustrate the usefulness of this technique, these measurements have been compared with the results obtained by the following conventional techniques: photoluminescence, transmittance and contactless electroreflectance. Amongst all these techniques, only PA spectroscopy exhibited signal without the undesired Fabry-Perot interferences arising from the thin film and buffer layer. By accurately assessing the strain state and composition of our samples, we were able to study the compositional dependence of the band gap of our epilayers. Our results show that a bowing parameter of 1.43 eV successfully describes the compositional dependence of the band gap of InGaN.

  8. A three-image algorithm for hard x-ray grating interferometry.

    PubMed

    Pelliccia, Daniele; Rigon, Luigi; Arfelli, Fulvia; Menk, Ralf-Hendrik; Bukreeva, Inna; Cedola, Alessia

    2013-08-12

    A three-image method to extract absorption, refraction and scattering information for hard x-ray grating interferometry is presented. The method comprises a post-processing approach alternative to the conventional phase stepping procedure and is inspired by a similar three-image technique developed for analyzer-based x-ray imaging. Results obtained with this algorithm are quantitatively comparable with phase-stepping. This method can be further extended to samples with negligible scattering, where only two images are needed to separate absorption and refraction signal. Thanks to the limited number of images required, this technique is a viable route to bio-compatible imaging with x-ray grating interferometer. In addition our method elucidates and strengthens the formal and practical analogies between grating interferometry and the (non-interferometric) diffraction enhanced imaging technique.

  9. A rigorous assessment of tree height measurements obtained using airborne LIDAR and conventional field methods.

    Treesearch

    Hans-Erik Andersen; Stephen E. Reutebuch; Robert J. McGaughey

    2006-01-01

    Tree height is an important variable in forest inventory programs but is typically time-consuming and costly to measure in the field using conventional techniques. Airborne light detection and ranging (LIDAR) provides individual tree height measurements that are highly correlated with field-derived measurements, but the imprecision of conventional field techniques does...

  10. An ex vivo comparison of pressures within dental pulp space using conventional anesthetic technique versus needle-mounted obturator.

    PubMed

    Grubbs, S Lee; Alley, Larry W; Eleazer, Paul D

    2014-07-01

    The intrapulpal (IP) injection technique is 1 of several ways of obtaining profound anesthesia. There is evidence to suggest that pressure is the primary factor in obtaining anesthesia using IP injection. This is an ex vivo comparison of pressures within dental pulp space using the conventional anesthetic technique versus a needle-mounted obturator technique. Twenty extracted anterior and premolar teeth were accessed with a high-speed 169L bur. A saline-filled tube connected to a digital pressure gauge was attached to the apical 10 mm of each tooth in a fixed mount. One operator performed all the injections under moderate pressure. Each tooth was injected twice; first, the tooth was given an IP injection with a normal setup, and then the same tooth was given an IP injection with the modified obturator syringe. The pressure at the apex was recorded for each tooth. A paired sample t test was completed to determine statistical significance. The pressure generated was considerably higher for the obturator group in every tooth when compared with the normal group (P < .001). IP injection with the obturator resulted in increased pressure at the apex of each tooth. This pressure increase may allow for increased anesthesia when IP injections are indicated. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. Detection of bacteraemias during non-surgicalroot canal treatment.

    PubMed

    Savarrio, L; Mackenzie, D; Riggio, M; Saunders, W P; Bagg, J

    2005-04-01

    Some dental procedures initiate a bacteraemia. In certain compromised patients, this bacteraemia may lead to distant site infections, most notably infective endocarditis. To investigate whether a detectable bacteraemia was produced during non-surgical root canal therapy. Thirty patients receiving non-surgical root canal therapy were studied. Three blood samples were taken per patient: pre-operatively, peri-operatively and post-operatively. In addition, a paper point sample was collected from the root canal. The blood samples were cultured by pour plate and blood bottle methods. The isolated organisms were identified by standard techniques. Blood samples were analysed for the presence of bacterial DNA by the polymerase chain reaction (PCR). In two cases where the same species of organism was identified in the root canal and the bloodstream, the isolates were typed by pulsed field gel electrophoresis (PFGE). By conventional culturing, a detectable bacteraemia was present in 9 (30%) of the 30 patients who had no positive pre-operative control blood sample. In 7 (23.3%) patients, the same species of organism was identified in both the bloodstream and in the paper point sample from the root canal system. Overall, PCR gave lower detection rates compared with conventional culture, with 10 of 90 (11%) of the blood samples displaying bacterial DNA. PFGE typing was undertaken for two pairs of culture isolates from blood and paper points; these were found to be genetically identical. Non-surgical root canal treatment may invoke a detectable bacteraemia.

  12. Improved radiocarbon dating for contaminated archaeological bone collagen, silk, wool and hair samples via cross-flow nanofiltrated amino acids.

    PubMed

    Boudin, Mathieu; Boeckx, Pascal; Vandenabeele, Peter; Van Strydonck, Mark

    2013-09-30

    Radiocarbon dating and stable isotope analyses of bone collagen, wool, hair and silk contaminated with extraneous carbon (e.g. humic substances) does not yield reliable results if these materials are pre-treated using conventional methods. A cross-flow nanofiltration method was developed that can be applied to various protein materials like collagen, hair, silk, wool and leather, and should be able to remove low-molecular and high-molecular weight contaminants. To avoid extraneous carbon contamination via the filter a ceramic filter (molecular weight cut-off of 200 Da) was used. The amino acids, released by hot acid hydrolysis of the protein material, were collected in the permeate and contaminants in the retentate (>200 Da). (14)C-dating results for various contaminated archaeological samples were compared for bulk material (pre-treated with the conventional methods) and for cross-flow nanofiltrated amino acids (permeate) originating from the same samples. Contamination and quality control of (14)C dates of bulk and permeate samples were obtained by measuring C:N ratios, fluorescence spectra, and δ(13)C and δ(15)N values of the samples. Cross-flow nanofiltration decreases the C:N ratio which means that contaminants have been removed. Cross-flow nanofiltration clearly improved sample quality and (14)C results. It is a quick and non-labor-intensive technique and can easily be implemented in any (14)C and stable isotope laboratory for routine sample pre-treatment analyses. Copyright © 2013 John Wiley & Sons, Ltd.

  13. Combined micro-droplet and thin-film-assisted pre-concentration of lead traces for on-line monitoring using anodic stripping voltammetry.

    PubMed

    Belostotsky, Inessa; Gridin, Vladimir V; Schechter, Israel; Yarnitzky, Chaim N

    2003-02-01

    An improved analytical method for airborne lead traces is reported. It is based on using a Venturi scrubber sampling device for simultaneous thin-film stripping and droplet entrapment of aerosol influxes. At least threefold enhancement of the lead-trace pre-concentration is achieved. The sampled traces are analyzed by square-wave anodic stripping voltammetry. The method was tested by a series of pilot experiments. These were performed using contaminant-controlled air intakes. Reproducible calibration plots were obtained. The data were validated by traditional analysis using filter sampling. LODs are comparable with the conventional techniques. The method was successfully applied to on-line and in situ environmental monitoring of lead.

  14. Fabrication and characterization of bioactive glass-ceramic using soda-lime-silica waste glass.

    PubMed

    Abbasi, Mojtaba; Hashemi, Babak

    2014-04-01

    Soda-lime-silica waste glass was used to synthesize a bioactive glass-ceramic through solid-state reactions. In comparison with the conventional route, that is, the melt-quenching and subsequent heat treatment, the present work is an economical technique. Structural and thermal properties of the samples were examined by X-ray diffraction (XRD) and differential thermal analysis (DTA). The in vitro test was utilized to assess the bioactivity level of the samples by Hanks' solution as simulated body fluid (SBF). Bioactivity assessment by atomic absorption spectroscopy (AAS) and scanning electron microscopy (SEM) was revealed that the samples with smaller amount of crystalline phase had a higher level of bioactivity. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Transport properties of Nd0.67Sr0.33Mn0.85Co0.15O3 manganite

    NASA Astrophysics Data System (ADS)

    Bhargav, Abhinav; Tank, Tejas M.; Sanyal, Sankar P.

    2018-05-01

    We have studied the structural and electrical transport properties of Nd0.67Sr0.33Mn0.85Co0.15O3 manganite prepared through conventional solid state reaction technique. The investigation of X-ray diffraction data and rietvield refinement show that the synthesized sample is single phase in nature and crystallizes in orthorhombic perovskite structure with Pbnm space group. The resistivity versus temperature measurement for sample Nd0.67Sr0.33Mn0.85Co0.15O3 was performed in the range 0-300K and at 0T field. The electrical transport mechanism of the sample is analyzed by different theoretical models, for temperatures below and above TP.

  16. Rietveld refinement and electrical properties of Ni-Zn spinel ferrites

    NASA Astrophysics Data System (ADS)

    Hooda, Ashima; Sanghi, Sujata; Agarwal, Ashish; Khasa, Satish; Hooda, Bhawana

    2017-05-01

    NiFe2O4, ZnFe2O4, Ni0.5Zn0.5Fe2O4 spinel samples have been synthesized by conventional solid state reaction technique. Powder X-ray diffraction and Rietveld refinement revealed that the samples were single Spinel phase with space group fd3m. The average crystalline size (D), lattice constant (a), X-ray density (ρx), measured density (ρm) and Porosity (P) of prepared samples were determined from XRD data. The dc electrical resistivity (p) was measured as a function of temperature. The variations of ρ were explained on the basis of Verwey and de Bohr mechanism. The value of DC resistivity found to increase with increase Zn concentration.

  17. Comparison of marginal and internal adaptation of copings fabricated from three different fabrication techniques: An in vitro study.

    PubMed

    Arora, Aman; Yadav, Avneet; Upadhyaya, Viram; Jain, Prachi; Verma, Mrinalini

    2018-01-01

    The purpose of this study was to compare the marginal and internal adaptation of cobalt-chromium (Co-Cr) copings fabricated from conventional wax pattern, three-dimensional (3D)-printed resin pattern, and laser sintering technique. A total of thirty copings were made, out of which ten copings were made from 3D-printed resin pattern (Group A), ten from inlay wax pattern (Group B), and ten copings were obtained from direct metal laser sintering (DMLS) technique (Group C). All the thirty samples were seated on their respective dies and sectioned carefully using a laser jet cutter and were evaluated for marginal and internal gaps at the predetermined areas using a stereomicroscope. The values were then analyzed using one-way ANOVA test and post hoc Bonferroni test. One-way ANOVA showed lowest mean marginal discrepancy for DMLS and highest value for copings fabricated from inlay wax. The values for internal discrepancy were highest for DMLS (169.38) and lowest for 3D-printed resin pattern fabricated copings (133.87). Post hoc Bonferroni test for both marginal and internal discrepancies showed nonsignificant difference when Group A was compared to Group B ( P > 0.05) and significant when Group A was compared with Group C ( P < 0.05). Group B showed significant difference ( P < 0.05) when compared with Group C. Marginal and internal discrepancies of all the three casting techniques were within clinically acceptable values. Marginal fit of DMLS was superior as compared to other two techniques, whereas when internal fit was evaluated, conventional technique showed the best internal fit.

  18. Modified fluoroscopy-guided sacroiliac joint injection: a technical report.

    PubMed

    Liliang, Po-Chou; Liang, Cheng-Loong; Lu, Kang; Weng, Hui-Ching; Syu, Fei-Kai

    2014-09-01

    Sacroiliac joint (SIJ) injection can occasionally be challenging. We describe our experience in using conventional technique, and we developed an adjustment to overcome difficulties incurred. Conventional technique required superimposition of the posterior and anterior SIJ lines. If this technique failed to provide entry into the joint, fluoroscopy was slightly adjusted to obtain an oblique view. Of 50 SIJ injections, 29 (58%; 44-72%) were successfully performed using conventional technique. In another 21 procedures, 18 (85.7%; 64-99%) were subsequently completed using oblique view technique. The medial joint line, viewed from this angle, corresponded to the posterior joint line in 17 cases. The lateral joint line corresponded to the posterior joint line in one case. Oblique view technique can improve the success rate of SIJ injection. Wiley Periodicals, Inc.

  19. Detection of hepatitis A viral antigen by radioimmunoassay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hollinger, F.B.; Bradley, D.W.; Maynard, J.E.

    1975-11-01

    With coded samples, the effectiveness and specificity of a micro-SPIRA procedure for rapidly and quantitatively detecting type A hepatitis-associated antigen in large numbers of specimens from infected liver, stool, or serum has been demonstrated. Samples which were judged to be negative by IEM were found to contain significant levels of HAV antigen by this immunoradiometric technique. The detection of significant levels of HAV antigen in infected chimpanzees supports epidemiologic evidence of viremia during the acute stage of the disease. The results of this study suggest that the diagnosis of type A hepatitis by a convention serologic procedure may now bemore » at hand. (auth)« less

  20. PIXE analysis on Maya blue in Prehispanic and colonial mural paintings

    NASA Astrophysics Data System (ADS)

    Sánchez del Río, M.; Martinetto, P.; Solís, C.; Reyes-Valerio, C.

    2006-08-01

    Particle induced X-ray emission (PIXE) experiments have been carried out at the AGLAE facility (Paris) on several mural samples containing Maya blue from different Prehispanic archaeological sites (Cacaxtla, El Tajín, Tamuin, Santa Cecilia Acatitlán) and from several colonial convents in the Mexican plateau (Jiutepec, Totimehuacán, Tezontepec and Cuauhtinchán). The analysis of the concentration of several elements permitted to extract some information on the technique used for painting the mural, usually fresco. Principal component analysis permitted to classify the samples into groups. This grouping is discussed in relation to geographic and historic data.

  1. Diversity of micro-fungi in an Antarctic dry valley

    NASA Technical Reports Server (NTRS)

    Baublis, J. A.; Wharton, R. A. Jr; Volz, P. A.; Wharton RA, J. r. (Principal Investigator)

    1991-01-01

    The fungal microflora of a dry valley in Southern Victoria Land near McMurdo Sound, Antarctica, was investigated. Samples were collected from introduced objects such as a mummified penguin and spent chewing tobacco in addition to the sparse soil found in rock fissures, isolated moss colonies, shoreline deposit materials, CaCO3 precipitates, and microbial mat debris obtained from the frozen surface of the lake in the basin of Taylor Valley. Using conventional media and techniques, all collection sites yielded populations of yeasts and filamentous fungi. Water samples and live microbial mats from beneath the lake ice yielded species of fungi along with an abundance of bacteria.

  2. Characterization of a Laser Surface-Treated Martensitic Stainless Steel.

    PubMed

    Al-Sayed, S R; Hussein, A A; Nofal, A A; Hassab Elnaby, S I; Elgazzar, H

    2017-05-29

    Laser surface treatment was carried out on AISI 416 machinable martensitic stainless steel containing 0.225 wt.% sulfur. Nd:YAG laser with a 2.2-KW continuous wave was used. The aim was to compare the physical and chemical properties achieved by this type of selective surface treatment with those achieved by the conventional treatment. Laser power of different values (700 and 1000 W) with four corresponding different laser scanning speeds (0.5, 1, 2, and 3 m•min-1) was adopted to reach the optimum conditions for impact toughness, wear, and corrosion resistance for laser heat treated (LHT) samples. The 0 °C impact energy of LHT samples indicated higher values compared to the conventionally heat treated (CHT) samples. This was accompanied by the formation of a hard surface layer and a soft interior base metal. Microhardness was studied to determine the variation of hardness values with respect to the depth under the treated surface. The wear resistance at the surface was enhanced considerably. Microstructure examination was characterized using optical and scanning electron microscopes. The corrosion behavior of the LHT samples was also studied and its correlation with the microstructures was determined. The corrosion data was obtained in 3.5% NaCl solution at room temperature by means of a potentiodynamic polarization technique.

  3. Characterization of a Laser Surface-Treated Martensitic Stainless Steel

    PubMed Central

    Al-Sayed, S. R.; Hussein, A. A.; Nofal, A. A.; Hassab Elnaby, S. I.; Elgazzar, H.

    2017-01-01

    Laser surface treatment was carried out on AISI 416 machinable martensitic stainless steel containing 0.225 wt.% sulfur. Nd:YAG laser with a 2.2-KW continuous wave was used. The aim was to compare the physical and chemical properties achieved by this type of selective surface treatment with those achieved by the conventional treatment. Laser power of different values (700 and 1000 W) with four corresponding different laser scanning speeds (0.5, 1, 2, and 3 m·min−1) was adopted to reach the optimum conditions for impact toughness, wear, and corrosion resistance for laser heat treated (LHT) samples. The 0 °C impact energy of LHT samples indicated higher values compared to the conventionally heat treated (CHT) samples. This was accompanied by the formation of a hard surface layer and a soft interior base metal. Microhardness was studied to determine the variation of hardness values with respect to the depth under the treated surface. The wear resistance at the surface was enhanced considerably. Microstructure examination was characterized using optical and scanning electron microscopes. The corrosion behavior of the LHT samples was also studied and its correlation with the microstructures was determined. The corrosion data was obtained in 3.5% NaCl solution at room temperature by means of a potentiodynamic polarization technique. PMID:28772955

  4. Application of a novel combination of near-infrared spectroscopy and a humidity-controlled 96-well plate to the characterization of the polymorphism of imidafenacin.

    PubMed

    Uchida, Hiroshi; Yoshinaga, Tokuji; Mori, Hirotoshi; Otsuka, Makoto

    2010-11-01

    This study aimed to apply a currently available chemometric near-infrared spectroscopy technique to the characterization of the polymorphic properties of drug candidates. The technique requires only small quantities of samples and is therefore applicable to drugs in the early stages of development. The combination of near-infrared spectroscopy and a patented 96-well plate divided into 32 individual, humidity-controlled, three-well compartments was used in the characterization of a hygroscopic drug, imidafenacin, which has two polymorphs and one pseudo-polymorph. Characterization was also conducted with powder X-ray diffraction and thermal analysis. The results were compared with those from routinely used conventional analyses. Both the microanalysis and conventional analysis successfully characterised the substance (transformation and relative stability among the two polymorphs and a pseudo-polymorph) depending on the storage conditions. Near-infrared spectroscopic analyses utilizing a humidity-controlled 96-well plate required only small amounts of the sample for characterization under the various conditions of relative humidity. Near-infrared microanalysis can be applied to polymorphic studies of small quantities of a drug candidate. The results also suggest that the method will predict the behaviors of a hygroscopic candidate in solid pharmaceutical preparations at the early stages of drug development. © 2010 The Authors. JPP © 2010 Royal Pharmaceutical Society of Great Britain.

  5. Heavy metal concentrations in soils as determined by laser-induced breakdown spectroscopy (LIBS), with special emphasis on chromium.

    PubMed

    Senesi, G S; Dell'Aglio, M; Gaudiuso, R; De Giacomo, A; Zaccone, C; De Pascale, O; Miano, T M; Capitelli, M

    2009-05-01

    Soil is unanimously considered as one of the most important sink of heavy metals released by human activities. Heavy metal analysis of natural and polluted soils is generally conducted by the use of atomic absorption spectroscopy (AAS) or inductively coupled plasma optical emission spectroscopy (ICP-OES) on adequately obtained soil extracts. Although in recent years the emergent technique of laser-induced breakdown spectroscopy (LIBS) has been applied widely and with increasing success for the qualitative and quantitative analyses of a number of heavy metals in soil matrices with relevant simplification of the conventional methodologies, the technique still requires further confirmation before it can be applied fully successfully in soil analyses. The main objective of this work was to demonstrate that new developments in LIBS technique are able to provide reliable qualitative and quantitative analytical evaluation of several heavy metals in soils, with special focus on the element chromium (Cr), and with reference to the concentrations measured by conventional ICP spectroscopy. The preliminary qualitative LIBS analysis of five soil samples and one sewage sludge sample has allowed the detection of a number of elements including Al, Ca, Cr, Cu, Fe, Mg, Mn, Pb, Si, Ti, V and Zn. Of these, a quantitative analysis was also possible for the elements Cr, Cu, Pb, V and Zn based on the obtained linearity of the calibration curves constructed for each heavy metal, i.e., the proportionality between the intensity of the LIBS emission peaks and the concentration of each heavy metal in the sample measured by ICP. In particular, a triplet of emission lines for Cr could be used for its quantitative measurement. The consistency of experiments made on various samples was supported by the same characteristics of the laser-induced plasma (LIP), i.e., the typical linear distribution confirming the existence of local thermodynamic equilibrium (LTE) condition, and similar excitation temperatures and comparable electron number density measured for all samples. An index of the anthropogenic contribution of Cr in polluted soils was calculated in comparison to a non-polluted reference soil. Thus, the intensity ratios of the emission lines of heavy metal can be used to detect in few minutes the polluted areas for which a more detailed sampling and analysis can be useful.

  6. Optical spectroscopy combined with high-resolution magnetic resonance imaging for digestive wall assessment: endoluminal bimodal probe conception and characterization in vitro, on organic sample and in vivo on a rabbit

    NASA Astrophysics Data System (ADS)

    Ramgolam, Anoop; Sablong, Raphaël; Lafarge, Lionel; Saint-Jalmes, Hervé; Beuf, Olivier

    2011-11-01

    Colorectal cancer is a major health issue worldwide. Conventional white light endoscopy (WLE) coupled to histology is considered as the gold standard today and is the most widespread technique used for colorectal cancer diagnosis. However, during the early stages, colorectal cancer is very often characterized by flat adenomas which develop just underneath the mucosal surface. The use of WLE, which is heavily based on the detection of morphological changes, becomes quite delicate due to subtle or quasi-invisible morphological changes of the colonic lining. Several techniques are currently being investigated in the scope of providing new tools that would allow such a diagnostic or assist actual techniques in so doing. We hereby present a novel technique where high spatial resolution MRI is combined with autofluorescence and reflectance spectroscopy in a bimodal endoluminal probe to extract morphological data and biochemical information, respectively. The design and conception of the endoluminal probe are detailed and the promising preliminary results obtained in vitro (home-built phantom containing eosin and rhodamine B), on an organic sample (the kiwi fruit) and in vivo on a rabbit are presented and discussed.

  7. Effects of sterilization treatments on bulk and surface properties of nanocomposite biomaterials

    PubMed Central

    Ahmed, Maqsood; Punshon, Geoffrey; Darbyshire, Arnold; Seifalian, Alexander M

    2013-01-01

    With the continuous and expanding use of implantable biomaterials in a clinical setting, this study aims to elucidate the influence of sterilization techniques on the material surface and bulk properties of two polyurethane nanocomposite biomaterials. Both solid samples and porous membranes of nondegradable polyhedral oligomeric silsesquioxane poly(carbonate-urea) urethane (POSS-PCU) and a biodegradable poly(caprolactone-urea) urethane (POSS-PCL) were examined. Sterilization techniques included conventional steam sterilization (autoclaving), gamma irradiation, and disinfection via incubating with ethanol (EtOH) for 10 min or 24 h. After treatment, the samples were examined using gel permeation chromatography (GPC), attenuated total reflectance Fourier transform infrared spectroscopy, and tensiometry. Cytotoxicity was evaluated through the culture of endothelial progenitor cells and the efficacy of sterilization method was determined by incubating each sample in tryptone soya broth and fluid thioglycollate medium for cultivation of microorganisms. Although EtOH did not affect the material properties in any form, the samples were found to be nonsterile with microbial growth detected on each of the samples. Gamma irradiation was not only effective in sterilizing both POSS-PCU and POSS-PCL but also led to minor material degradation and displayed a cytotoxic effect on the cultured cells. Autoclaving was found to be the optimal sterilization technique for both solid and porous membranes of the nondegradable POSS-PCU samples as it was successful in sterilizing the samples, displayed no cytotoxic side effects and did not degrade the material. However, the biodegradable POSS-PCL was not able to withstand the harsh environment during autoclaving, resulting in it losing all structural integrity. PMID:24039066

  8. Accuracy of Conventional and Digital Radiography in Detecting External Root Resorption

    PubMed Central

    Mesgarani, Abbas; Haghanifar, Sina; Ehsani, Maryam; Yaghub, Samereh Dokhte; Bijani, Ali

    2014-01-01

    Introduction: External root resorption (ERR) is associated with physiological and pathological dissolution of mineralized tissues by clastic cells and radiography is one of the most important methods in its diagnosis. The aim of this experimental study was to evaluate the accuracy of conventional intraoral radiography (CR) in comparison with digital radiographic techniques, i.e. charge-coupled device (CCD) and photo-stimulable phosphor (PSP) sensors, in detection of ERR. Methods and Materials: This study was performed on 80 extracted human mandibular premolars. After taking separate initial periapical radiographs with CR technique, CCD and PSP sensors, the artificial defects resembling ERR with variable sizes were created in apical half of the mesial, distal and buccal surfaces of the teeth. Ten teeth were used as control samples without any resorption. The radiographs were then repeated with 2 different exposure times and the images were observed by 3 observers. Data were analyzed using SPSS version 17 and chi-squared and Cohen’s Kappa tests with 95% confidence interval (CI=95%). Result: The CCD had the highest percentage of correct assessment compared to the CR and PSP sensors, although the difference was not significant (P=0.39). It was shown that the higher dosage of radiation increases the accuracy of diagnosis; however, it was only significant for CCD sensor (P=0.02). Also, the accuracy of diagnosis increased with the increase in the size of lesion (P=0.001). Conclusion: Statistically significant difference was not observed for accurate detection of ERR by conventional and digital radiographic techniques. PMID:25386202

  9. Fracture behavior of metal-ceramic fixed dental prostheses with frameworks from cast or a newly developed sintered cobalt-chromium alloy.

    PubMed

    Krug, Klaus-Peter; Knauber, Andreas W; Nothdurft, Frank P

    2015-03-01

    The aim of this study was to investigate the fracture behavior of metal-ceramic bridges with frameworks from cobalt-chromium-molybdenum (CoCrMo), which are manufactured using conventional casting or a new computer-aided design/computer-aided manufacturing (CAD/CAM) milling and sintering technique. A total of 32 metal-ceramic fixed dental prostheses (FDPs), which are based on a nonprecious metal framework, was produced using a conventional casting process (n = 16) or a new CAD/CAM milling and sintering process (n = 16). Eight unveneered frameworks were manufactured using each of the techniques. After thermal and mechanical aging of half of the restorations, all samples were subjected to a static loading test in a universal testing machine, in which acoustic emission monitoring was performed. Three different critical forces were revealed: the fracture force (F max), the force at the first reduction in force (F decr1), and the force at the critical acoustic event (F acoust1). With the exception of the veneered restorations with cast or sintered metal frameworks without artificial aging, which presented a statistically significant but slightly different F max, no statistically significant differences between cast and CAD/CAM sintered and milled FDPs were detected. Thermal and mechanical loading did not significantly affect the resulting forces. Cast and CAD/CAM milled and sintered metal-ceramic bridges were determined to be comparable with respect to the fracture behavior. FDPs based on CAD/CAM milled and sintered frameworks may be an applicable and less technique-sensitive alternative to frameworks that are based on conventionally cast frameworks.

  10. Characterization of the Etna volcanic emissions through an active biomonitoring technique (moss-bags): part 2--morphological and mineralogical features.

    PubMed

    Calabrese, S; D'Alessandro, W

    2015-01-01

    Volcanic emissions were studied at Mount Etna (Italy) by using moss-bags technique. Mosses were exposed around the volcano at different distances from the active vents to evaluate the impact of volcanic emissions in the atmosphere. Morphology and mineralogy of volcanic particulate intercepted by mosses were investigated using scanning electron microscopy (SEM) equipped with energy dispersive spectrometer (EDS). Particles emitted during passive degassing activity from the two active vents, Bocca Nuova and North East Crater (BNC and NEC), were identified as silicates, sulfates and halide compounds. In addition to volcanic particles, we found evidences also of geogenic, anthropogenic and marine spray input. The study has shown the robustness of this active biomonitoring technique to collect particles, very useful in active volcanic areas characterized by continuous degassing and often not easily accessible to apply conventional sampling techniques. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Dimensional changes of acrylic resin denture bases: conventional versus injection-molding technique.

    PubMed

    Gharechahi, Jafar; Asadzadeh, Nafiseh; Shahabian, Foad; Gharechahi, Maryam

    2014-07-01

    Acrylic resin denture bases undergo dimensional changes during polymerization. Injection molding techniques are reported to reduce these changes and thereby improve physical properties of denture bases. The aim of this study was to compare dimensional changes of specimens processed by conventional and injection-molding techniques. SR-Ivocap Triplex Hot resin was used for conventional pressure-packed and SR-Ivocap High Impact was used for injection-molding techniques. After processing, all the specimens were stored in distilled water at room temperature until measured. For dimensional accuracy evaluation, measurements were recorded at 24-hour, 48-hour and 12-day intervals using a digital caliper with an accuracy of 0.01 mm. Statistical analysis was carried out by SPSS (SPSS Inc., Chicago, IL, USA) using t-test and repeated-measures ANOVA. Statistical significance was defined at P<0.05. After each water storage period, the acrylic specimens produced by injection exhibited less dimensional changes compared to those produced by the conventional technique. Curing shrinkage was compensated by water sorption with an increase in water storage time decreasing dimensional changes. Within the limitations of this study, dimensional changes of acrylic resin specimens were influenced by the molding technique used and SR-Ivocap injection procedure exhibited higher dimensional accuracy compared to conventional molding.

  12. Dimensional Changes of Acrylic Resin Denture Bases: Conventional Versus Injection-Molding Technique

    PubMed Central

    Gharechahi, Jafar; Asadzadeh, Nafiseh; Shahabian, Foad; Gharechahi, Maryam

    2014-01-01

    Objective: Acrylic resin denture bases undergo dimensional changes during polymerization. Injection molding techniques are reported to reduce these changes and thereby improve physical properties of denture bases. The aim of this study was to compare dimensional changes of specimens processed by conventional and injection-molding techniques. Materials and Methods: SR-Ivocap Triplex Hot resin was used for conventional pressure-packed and SR-Ivocap High Impact was used for injection-molding techniques. After processing, all the specimens were stored in distilled water at room temperature until measured. For dimensional accuracy evaluation, measurements were recorded at 24-hour, 48-hour and 12-day intervals using a digital caliper with an accuracy of 0.01 mm. Statistical analysis was carried out by SPSS (SPSS Inc., Chicago, IL, USA) using t-test and repeated-measures ANOVA. Statistical significance was defined at P<0.05. Results: After each water storage period, the acrylic specimens produced by injection exhibited less dimensional changes compared to those produced by the conventional technique. Curing shrinkage was compensated by water sorption with an increase in water storage time decreasing dimensional changes. Conclusion: Within the limitations of this study, dimensional changes of acrylic resin specimens were influenced by the molding technique used and SR-Ivocap injection procedure exhibited higher dimensional accuracy compared to conventional molding. PMID:25584050

  13. Intraseptal anesthesia: a review of a relevant injection technique.

    PubMed

    Woodmansey, Karl

    2005-01-01

    Although overshadowed by intraosseous anesthesia and the periodontal ligament injection, intraseptal anesthesia remains a useful local anesthesia technique for general dentists. Intraseptal anesthesia can be employed with safety and efficacy as an alternative to conventional local infiltration or regional nerve block injections. It also can serve as an adjunctive technique when conventional techniques fail to achieve adequate local anesthesia. This article reviews the intraseptal anesthesia technique, including its indications and limitations.

  14. Efficiency of two-way weirs and prepositioned electrofishing for sampling potamodromous fish migrations

    USGS Publications Warehouse

    Favrot, Scott D.; Kwak, Thomas J.

    2016-01-01

    Potamodromy (i.e., migration entirely in freshwater) is a common life history strategy of North American lotic fishes, and efficient sampling methods for potamodromous fishes are needed to formulate conservation and management decisions. Many potamodromous fishes inhabit medium-sized rivers and are mobile during spawning migrations, which complicates sampling with conventional gears (e.g., nets and electrofishing). We compared the efficiency of a passive migration technique (resistance board weirs) and an active technique (prepositioned areal electrofishers; [PAEs]) for sampling migrating potamodromous fishes in Valley River, a southern Appalachian Mountain river, from March through July 2006 and 2007. A total of 35 fish species from 10 families were collected, 32 species by PAE and 19 species by weir. Species richness and diversity were higher for PAE catch, and species dominance (i.e., proportion of assemblage composed of the three most abundant species) was higher for weir catch. Prepositioned areal electrofisher catch by number was considerably higher than weir catch, but biomass was lower for PAE catch. Weir catch decreased following the spawning migration, while PAEs continued to collect fish. Sampling bias associated with water velocity was detected for PAEs, but not weirs, and neither gear demonstrated depth bias in wadeable reaches. Mean fish mortality from PAEs was five times greater than that from weirs. Catch efficiency and composition comparisons indicated that weirs were effective at documenting migration chronology, sampling nocturnal migration, and yielding samples unbiased by water velocity or habitat, with low mortality. Prepositioned areal electrofishers are an appropriate sampling technique for seasonal fish occupancy objectives, while weirs are more suitable for quantitatively describing spawning migrations. Our comparative results may guide fisheries scientists in selecting an appropriate sampling gear and regime for research, monitoring, conservation, and management of potamodromous fishes.

  15. Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Xuefei; Kelly, Ryan T.; Danielson, William F.

    2011-04-26

    A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersectionmore » geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, no sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed.« less

  16. Reduced aliasing artifacts using shaking projection k-space sampling trajectory

    NASA Astrophysics Data System (ADS)

    Zhu, Yan-Chun; Du, Jiang; Yang, Wen-Chao; Duan, Chai-Jie; Wang, Hao-Yu; Gao, Song; Bao, Shang-Lian

    2014-03-01

    Radial imaging techniques, such as projection-reconstruction (PR), are used in magnetic resonance imaging (MRI) for dynamic imaging, angiography, and short-T2 imaging. They are less sensitive to flow and motion artifacts, and support fast imaging with short echo times. However, aliasing and streaking artifacts are two main sources which degrade radial imaging quality. For a given fixed number of k-space projections, data distributions along radial and angular directions will influence the level of aliasing and streaking artifacts. Conventional radial k-space sampling trajectory introduces an aliasing artifact at the first principal ring of point spread function (PSF). In this paper, a shaking projection (SP) k-space sampling trajectory was proposed to reduce aliasing artifacts in MR images. SP sampling trajectory shifts the projection alternately along the k-space center, which separates k-space data in the azimuthal direction. Simulations based on conventional and SP sampling trajectories were compared with the same number projections. A significant reduction of aliasing artifacts was observed using the SP sampling trajectory. These two trajectories were also compared with different sampling frequencies. A SP trajectory has the same aliasing character when using half sampling frequency (or half data) for reconstruction. SNR comparisons with different white noise levels show that these two trajectories have the same SNR character. In conclusion, the SP trajectory can reduce the aliasing artifact without decreasing SNR and also provide a way for undersampling reconstruction. Furthermore, this method can be applied to three-dimensional (3D) hybrid or spherical radial k-space sampling for a more efficient reduction of aliasing artifacts.

  17. Laser-induced breakdown spectroscopy (LIBS) technique for the determination of the chemical composition of complex inorganic materials

    NASA Astrophysics Data System (ADS)

    Łazarek, Łukasz; Antończak, Arkadiusz J.; Wójcik, Michał R.; Kozioł, Paweł E.; Stepak, Bogusz; Abramski, Krzysztof M.

    2014-08-01

    Laser-induced breakdown spectroscopy (LIBS) is a fast, fully optical method, that needs little or no sample preparation. In this technique qualitative and quantitative analysis is based on comparison. The determination of composition is generally based on the construction of a calibration curve namely the LIBS signal versus the concentration of the analyte. Typically, to calibrate the system, certified reference materials with known elemental composition are used. Nevertheless, such samples due to differences in the overall composition with respect to the used complex inorganic materials can influence significantly on the accuracy. There are also some intermediate factors which can cause imprecision in measurements, such as optical absorption, surface structure, thermal conductivity etc. This paper presents the calibration procedure performed with especially prepared pellets from the tested materials, which composition was previously defined. We also proposed methods of post-processing which allowed for mitigation of the matrix effects and for a reliable and accurate analysis. This technique was implemented for determination of trace elements in industrial copper concentrates standardized by conventional atomic absorption spectroscopy with a flame atomizer. A series of copper flotation concentrate samples was analyzed for contents of three elements, that is silver, cobalt and vanadium. It has been shown that the described technique can be used to qualitative and quantitative analyses of complex inorganic materials, such as copper flotation concentrates.

  18. Highly oriented carbon fiber–polymer composites via additive manufacturing

    DOE PAGES

    Tekinalp, Halil L.; Kunc, Vlastimil; Velez-Garcia, Gregorio M.; ...

    2014-10-16

    Additive manufacturing, diverging from traditional manufacturing techniques, such as casting and machining materials, can handle complex shapes with great design flexibility without the typical waste. Although this technique has been mainly used for rapid prototyping, interest is growing in using this method to directly manufacture actual parts of complex shape. To use 3D-printing additive manufacturing in wide spread applications, the technique and the feedstock materials require improvements to meet the mechanical requirements of load-bearing components. Thus, we investigated the short fiber (0.2 mm to 0.4 mm) reinforced acrylonitrile-butadiene-styrene composites as a feedstock for 3D-printing in terms of their processibility, microstructuremore » and mechanical performance; and also provided comparison with traditional compression molded composites. The tensile strength and modulus of 3D-printed samples increased ~115% and ~700%, respectively. 3D-printer yielded samples with very high fiber orientation in printing direction (up to 91.5 %), whereas, compression molding process yielded samples with significantly less fiber orientation. Microstructure-mechanical property relationships revealed that although the relatively high porosity is observed in the 3D-printed composites as compared to those produced by the conventional compression molding technique, they both exhibited comparable tensile strength and modulus. Furthermore, this phenomena is explained based on the changes in fiber orientation, dispersion and void formation.« less

  19. The effect of power intensity properties of microwave modified oil palm trunk lumber

    NASA Astrophysics Data System (ADS)

    Izzati Ibrahim, Anis; Salim, Nurjannah; Roslan, Rasidi; Ashry Jusoh, Mohammad; Hashim, Rokiah

    2018-04-01

    In the decade, oil palm (Elaeis guineensis) in Malaysia is one of the conventional sources that will be rising, and the rate of biomass will considerably increase in yet to come. Presently, oil palm biomass is going through research and development and appears to be the most sustainable alternative. Investigations on oil palm biomass have been conducted to support in draw out waste of oil palm and in the meantime can help economic yield to the country. This study was expected to estimate the effect of power intensity properties of microwave modified oil palm trunk lumber. Microwave treatment of oil palm trunk samples was set of connections by using a microwave operating at 2.45 GHz with the liberated process input power intensity (600-1000W) were studied under the given condition. Impact and compression of the samples were tested. The analysis of properties of the fresh material and dry samples was employed by scanning electron microscopy. Oven drying technique also was involved as a comparison of the conventional drying process in this research. Based on the outcomes of this study, both drying methods improved the characteristics of the specimens.

  20. Simulation of cryolipolysis as a novel method for noninvasive fat layer reduction.

    PubMed

    Majdabadi, Abbas; Abazari, Mohammad

    2016-12-20

    Regarding previous problems in conventional liposuction methods, the need for development of new fat removal operations was appreciated. In this study we are going to simulate one of the novel methods, cryolipolysis, aimed to tackle those drawbacks. We think that simulation of clinical procedures contributes considerably in efficacious performance of the operations. To do this we have attempted to simulate temperature distribution in a sample fat of the human body. Using Abaqus software we have presented the graphical display of temperature-time variations within the medium. Findings of our simulation indicate that tissue temperature decreases after cold exposure of about 30 min. It can be seen that the minimum temperature of tissue occurs in shallow layers of the sample and the temperature in deeper layers of the sample remains nearly unchanged. It is clear that cold exposure time of more than the specific time (t > 30 min) does not result in considerable changes. Numerous clinical studies have proved the efficacy of cryolipolysis. This noninvasive technique has eliminated some of drawbacks of conventional methods. Findings of our simulation clearly prove the efficiency of this method, especially for superficial fat layers.

  1. Optimization of heat treatment parameters for additive manufacturing and gravity casting AlSi10Mg alloy

    NASA Astrophysics Data System (ADS)

    Girelli, L.; Tocci, M.; Montesano, L.; Gelfi, M.; Pola, A.

    2017-11-01

    Additive manufacturing of metals is a production process developed in the last few years to realize net shape components with complex geometry and high performance. AlSi10Mg is one of the most widely used aluminium alloys, both in this field and in conventional foundry processes, for its significant mechanical properties combined with good corrosion resistance. In this paper the effect of heat treatment on AlSi10Mg alloy was investigated. Solution and ageing treatments were carried out with different temperatures and times on samples obtained by direct metal laser sintering and gravity casting in order to compare their performance. Microstructural analyses and hardness tests were performed to investigate the effectiveness of the heat treatment. The results were correlated to the sample microstructure and porosity, analysed by means of optical microscopy and density measurements. It was found that, in the additive manufactured samples, the heat treatment can reduce significantly the performance of the alloy also because of the increase of porosity due to entrapped gas during the deposition technique and that the higher the solution temperature the higher the increase of such defects. A so remarkable effect was not found in the conventional cast alloy.

  2. Non-Destructive Study of Bulk Crystallinity and Elemental Composition of Natural Gold Single Crystal Samples by Energy-Resolved Neutron Imaging

    PubMed Central

    Tremsin, Anton S.; Rakovan, John; Shinohara, Takenao; Kockelmann, Winfried; Losko, Adrian S.; Vogel, Sven C.

    2017-01-01

    Energy-resolved neutron imaging enables non-destructive analyses of bulk structure and elemental composition, which can be resolved with high spatial resolution at bright pulsed spallation neutron sources due to recent developments and improvements of neutron counting detectors. This technique, suitable for many applications, is demonstrated here with a specific study of ~5–10 mm thick natural gold samples. Through the analysis of neutron absorption resonances the spatial distribution of palladium (with average elemental concentration of ~0.4 atom% and ~5 atom%) is mapped within the gold samples. At the same time, the analysis of coherent neutron scattering in the thermal and cold energy regimes reveals which samples have a single-crystalline bulk structure through the entire sample volume. A spatially resolved analysis is possible because neutron transmission spectra are measured simultaneously on each detector pixel in the epithermal, thermal and cold energy ranges. With a pixel size of 55 μm and a detector-area of 512 by 512 pixels, a total of 262,144 neutron transmission spectra are measured concurrently. The results of our experiments indicate that high resolution energy-resolved neutron imaging is a very attractive analytical technique in cases where other conventional non-destructive methods are ineffective due to sample opacity. PMID:28102285

  3. Side effects and complications of intraosseous anesthesia and conventional oral anesthesia

    PubMed Central

    Peñarrocha-Oltra, David; Ata-Ali, Javier; Oltra-Moscardó, María J.; Peñarrocha, Miguel

    2012-01-01

    Objective: To analyze the side effects and complications following intraosseous anesthesia (IA), comparing them with those of the conventional oral anesthesia techniques. Material and method: A simple-blind, prospective clinical study was carried out. Each patient underwent two anesthetic techniques: conventional (local infiltration and locoregional anesthetic block) and intraosseous, for respective dental operations. In order to allow comparison of IA versus conventional anesthesia, the two operations were similar and affected the same two teeth in opposite quadrants. Heart rate was recorded in all cases before injection of the anesthetic solution and again 30 seconds after injection. The complications observed after anesthetic administration were recorded. Results: A total of 200 oral anesthetic procedures were carried out in 100 patients. Both IA and conventional anesthesia resulted in a significant increase in heart rate, though the increase was greater with the latter technique. Incidents were infrequent with either anesthetic technique, with no significant differences between them. Regarding the complications, there were significant differences in pain at the injection site, with more intense pain in the case of IA (x2=3.532, p=0.030, Φ2=0.02), while the limitation of oral aperture was more pronounced with conventional anesthesia (x2=5.128, p<0.05, Φ2=0.014). Post-anesthetic biting showed no significant differences (x2=4.082, p=0.121, Φ2=0.009). Conclusions: Both anesthetic techniques significantly increased heart rate, and IA caused comparatively more pain at the injection site, while limited oral aperture was more frequent with conventional anesthesia. Post-anesthetic biting showed no significant differences between the two techniques. Key words:Intraosseous anesthesia, oral anesthesia, mandibular block, heart rate, adrenalin, complications. PMID:22143716

  4. Effects of a cementing technique in addition to luting agent on the uniaxial retention force of a single-tooth implant-supported restoration: an in vitro study.

    PubMed

    Santosa, Robert E; Martin, William; Morton, Dean

    2010-01-01

    Excess residual cement around the implant margin has been shown to be detrimental to the peri-implant tissue. This in vitro study examines the retentive strengths of two different cementing techniques and two different luting agents on a machined titanium abutment and solid screw implants. The amount of reduction of excess cement weight between the two cementation techniques was assessed. Forty gold castings were fabricated for 4.1 mm in diameter and 10 mm in length solid-screw dental implants paired with 5.5-mm machined titanium abutments. Twenty implants received a provisional cement, and 20 implants received a definitive cement. Each group was further divided into two groups. In the control group, cement was applied and the castings seated over the implant-abutment assembly. The excess cement was then removed. In the study group, a "practice abutment" was used to express excess cement prior to cementation. The weight of the implant-casting assembly was measured and the residual weight of cement was calculated. The samples were then stored for 24 hours at 100% humidity prior to tensile strength testing. Statistical analysis revealed significant differences in tensile strength across the groups. Further Tukey tests showed no significant difference in tensile strength between the practice abutment technique and the conventional technique for both definitive and provisional cements. There was a significant reduction in residual cement weight, irrespective of the type of cement, when the practice abutment was used prior to cementation. Cementation of implant restorations on a machined abutment using the practice abutment technique and definitive cement may provide similar uniaxial retention force and significantly reduced residual cement weight compared to the conventional technique of cement removal.

  5. The Sine Method: An Alternative Height Measurement Technique

    Treesearch

    Don C. Bragg; Lee E. Frelich; Robert T. Leverett; Will Blozan; Dale J. Luthringer

    2011-01-01

    Height is one of the most important dimensions of trees, but few observers are fully aware of the consequences of the misapplication of conventional height measurement techniques. A new approach, the sine method, can improve height measurement by being less sensitive to the requirements of conventional techniques (similar triangles and the tangent method). We studied...

  6. Hot-wire anemometry in hypersonic helium flow

    NASA Technical Reports Server (NTRS)

    Wagner, R. D.; Weinstein, L. M.

    1974-01-01

    Hot-wire anemometry techniques are described that have been developed and used for hypersonic-helium-flow studies. The short run time available dictated certain innovations in applying conventional hot-wire techniques. Some examples are given to show the application of the techniques used. Modifications to conventional equipment are described, including probe modifications and probe heating controls.

  7. Comparison of surgically induced astigmatism in patients with horizontal rectus muscle recession

    PubMed Central

    Çakmak, Harun; Kocatürk, Tolga; Dündar, Sema Oruç

    2014-01-01

    AIM To compare surgically induced astigmatism (SIA) following horizontal rectus muscle recession surgery between suspension recession with both the “hang-back” technique and conventional recession technique. METHODS Totally, 48 eyes of 24 patients who had undergone horizontal rectus muscle recession surgery were reviewed retrospectively. The patients were divided into two groups. Twelve patients were operated on by the hang-back technique (Group 1), and 12 by the conventional recession technique (Group 2). SIA was calculated on the 1st wk, 1st and in the 3rd mo after surgery using the SIA calculator. RESULTS SIA was statistically higher in the Group 1 all postoperative follow-up. SIA was the highest in the 1st wk, and decreased gradually in both groups. CONCLUSION The suspension recession technique induced much more SIA than the conventional recession technique. This difference also continued in the following visits. Therefore, the refractive power should be checked postoperatively in order to avoid refractive amblyopia. Conventional recession surgery should be the preferred method so as to minimize the postoperative refractive changes in patients with amblyopia. PMID:25161948

  8. Comparison of computer-assisted surgery with conventional technique for the treatment of axial distal phalanx fractures in horses: an in vitro study.

    PubMed

    Andritzky, Juliane; Rossol, Melanie; Lischer, Christoph; Auer, Joerg A

    2005-01-01

    To compare the precision obtained with computer-assisted screw insertion for treatment of mid-sagittal articular fractures of the distal phalanx (P3) with results achieved with a conventional technique. In vitro experimental study. Thirty-two cadaveric equine limbs. Four groups of 8 limbs were studied. Either 1 or 2 screws were inserted perpendicular to an imaginary axial fracture of P3 using computer-assisted surgery (CAS) or conventional technique. Screw insertion time, predetermined screw length, inserted screw length, fit of the screw, and errors in placement were recorded. CAS technique took 15-20 minutes longer but resulted in greater precision of screw length and placement compared with the conventional technique. Improved precision in screw insertion with CAS makes insertion of 2 screws possible for repair of mid-sagittal P3 fractures. CAS although expensive improves precision in screw insertion into P3 and consequently should yield improved clinical outcome.

  9. Simultaneous topography and tomography of latent fingerprints using full-field swept-source optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Dubey, Satish Kumar; Singh Mehta, Dalip; Anand, Arun; Shakher, Chandra

    2008-01-01

    We demonstrate simultaneous topography and tomography of latent fingerprints using full-field swept-source optical coherence tomography (OCT). The swept-source OCT system comprises a superluminescent diode (SLD) as broad-band light source, an acousto-optic tunable filter (AOTF) as frequency tuning device, and a compact, nearly common-path interferometer. Both the amplitude and the phase map of the interference fringe signal are reconstructed. Optical sectioning of the latent fingerprint sample is obtained by selective Fourier filtering and the topography is retrieved from the phase map. Interferometry, selective filtering, low coherence and hence better resolution are some of the advantages of the proposed system over the conventional fingerprint detection techniques. The present technique is non-invasive in nature and does not require any physical or chemical processing. Therefore, the quality of the sample does not alter and hence the same fingerprint can be used for other types of forensic test. Exploitation of low-coherence interferometry for fingerprint detection itself provides an edge over other existing techniques as fingerprints can even be lifted from low-reflecting surfaces. The proposed system is very economical and compact.

  10. Rare cell isolation and analysis in microfluidics

    PubMed Central

    Chen, Yuchao; Li, Peng; Huang, Po-Hsun; Xie, Yuliang; Mai, John D.; Wang, Lin; Nguyen, Nam-Trung; Huang, Tony Jun

    2014-01-01

    Rare cells are low-abundance cells in a much larger population of background cells. Conventional benchtop techniques have limited capabilities to isolate and analyze rare cells because of their generally low selectivity and significant sample loss. Recent rapid advances in microfluidics have been providing robust solutions to the challenges in the isolation and analysis of rare cells. In addition to the apparent performance enhancements resulting in higher efficiencies and sensitivity levels, microfluidics provides other advanced features such as simpler handling of small sample volumes and multiplexing capabilities for high-throughput processing. All of these advantages make microfluidics an excellent platform to deal with the transport, isolation, and analysis of rare cells. Various cellular biomarkers, including physical properties, dielectric properties, as well as immunoaffinities, have been explored for isolating rare cells. In this Focus article, we discuss the design considerations of representative microfluidic devices for rare cell isolation and analysis. Examples from recently published works are discussed to highlight the advantages and limitations of the different techniques. Various applications of these techniques are then introduced. Finally, a perspective on the development trends and promising research directions in this field are proposed. PMID:24406985

  11. Effect of whey protein isolate and β-cyclodextrin wall systems on stability of microencapsulated vanillin by spray-freeze drying method.

    PubMed

    Hundre, Swetank Y; Karthik, P; Anandharamakrishnan, C

    2015-05-01

    Vanillin flavour is highly volatile in nature and due to that application in food incorporation is limited; hence microencapsulation of vanillin is an ideal technique to increase its stability and functionality. In this study, vanillin was microencapsulated for the first time by non-thermal spray-freeze-drying (SFD) technique and its stability was compared with other conventional techniques such as spray drying (SD) and freeze-drying (FD). Different wall materials like β-cyclodextrin (β-cyd), whey protein isolate (WPI) and combinations of these wall materials (β-cyd + WPI) were used to encapsulate vanillin. SFD microencapsulated vanillin with WPI showed spherical shape with numerous fine pores on the surface, which in turn exhibited good rehydration ability. On the other hand, SD powder depicted spherical shape without pores and FD encapsulated powder yielded larger particle sizes with flaky structure. FTIR analysis confirmed that there was no interaction between vanillin and wall materials. Moreover, spray-freeze-dried vanillin + WPI sample exhibited better thermal stability than spray dried and freeze-dried microencapsulated samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Review of combined isotopic and optical nanoscopy

    PubMed Central

    Richter, Katharina N.; Rizzoli, Silvio O.; Jähne, Sebastian; Vogts, Angela; Lovric, Jelena

    2017-01-01

    Abstract. Investigating the detailed substructure of the cell is beyond the ability of conventional optical microscopy. Electron microscopy, therefore, has been the only option for such studies for several decades. The recent implementation of several super-resolution optical microscopy techniques has rendered the investigation of cellular substructure easier and more efficient. Nevertheless, optical microscopy only provides an image of the present structure of the cell, without any information on its long-temporal changes. These can be investigated by combining super-resolution optics with a nonoptical imaging technique, nanoscale secondary ion mass spectrometry, which investigates the isotopic composition of the samples. The resulting technique, combined isotopic and optical nanoscopy, enables the investigation of both the structure and the “history” of the cellular elements. The age and the turnover of cellular organelles can be read by isotopic imaging, while the structure can be analyzed by optical (fluorescence) approaches. We present these technologies, and we discuss their implementation for the study of biological samples. We conclude that, albeit complex, this type of technology is reliable enough for mass application to cell biology. PMID:28466025

  13. Radiochemical determination of 241Am and Pu(alpha) in environmental materials.

    PubMed

    Warwick, P E; Croudace, I W; Oh, J S

    2001-07-15

    Americium-241 and plutonium determinations will become of greater importance over the coming decades as 137Cs and 241Pu decay. The impact of 137Cs on environmental chronology has been great, but its potency is waning as it decays and diffuses. Having 241Am and Pu as unequivocal markers for the 1963 weapon fallout maximum is important for short time scale environmental work, but a fast and reliable procedure is required for their separation. The developed method described here begins by digesting samples using a lithium borate fusion although an aqua regia leachate is also effective in many instances. Isolation of the Am and Pu is then achieved using a combination of extraction chromatography and conventional anion exchange chromatography. The whole procedure has been optimized, validated, and assessed for safety. The straightforwardness of this technique permits the analysis of large numbers of samples and makes 241Am-based techniques for high-resolution sediment accumulation rate studies attractive. In addition, the technique can be employed for the sequential measurement of Pu and Am in environmental surveillance programs, potentially reducing analytical costs and turnround times.

  14. A New Arbiter PUF for Enhancing Unpredictability on FPGA

    PubMed Central

    Machida, Takanori; Yamamoto, Dai; Iwamoto, Mitsugu; Sakiyama, Kazuo

    2015-01-01

    In general, conventional Arbiter-based Physically Unclonable Functions (PUFs) generate responses with low unpredictability. The N-XOR Arbiter PUF, proposed in 2007, is a well-known technique for improving this unpredictability. In this paper, we propose a novel design for Arbiter PUF, called Double Arbiter PUF, to enhance the unpredictability on field programmable gate arrays (FPGAs), and we compare our design to conventional N-XOR Arbiter PUFs. One metric for judging the unpredictability of responses is to measure their tolerance to machine-learning attacks. Although our previous work showed the superiority of Double Arbiter PUFs regarding unpredictability, its details were not clarified. We evaluate the dependency on the number of training samples for machine learning, and we discuss the reason why Double Arbiter PUFs are more tolerant than the N-XOR Arbiter PUFs by evaluating intrachip variation. Further, the conventional Arbiter PUFs and proposed Double Arbiter PUFs are evaluated according to other metrics, namely, their uniqueness, randomness, and steadiness. We demonstrate that 3-1 Double Arbiter PUF archives the best performance overall. PMID:26491720

  15. Determination of acrylamide in Thai-conventional snacks from Nong Mon market, Chonburi using GC-MS technique.

    PubMed

    Komthong, P; Suriyaphan, O; Charoenpanich, J

    2012-01-01

    Acrylamide in Thai-conventional snacks was analysed by GC/MS with a linear response ranged of 5-50 µg and r² > 0.99. The limit of detection (s/n = 3) and limit of quantification (s/n = 10) were 4 and 15 µg kg⁻¹, respectively, and RSD < 2%. Acrylamide in 19 food samples ranged from <15 µg kg⁻¹ to 1.26 mg kg⁻¹ with highest concentrations in Kanom Jak. Moderate levels (150-500 µg kg⁻¹) were detected mostly in deep-fried products, especially sweet potato and taro crisps, Kanom Kai Hong, banana fritters, durian chips and spring rolls. Thai-conventional snacks possessed low concentrations (<150 µg kg⁻¹) including Khao Larm, Pa Tong Koo, sweet banana crisps and deep-fried Chinese wonton. Acrylamide was lowest (<15 µg kg⁻¹) in fish strips, rice crackers, Hoi Jor and fried fish balls. Dietary habits by 400 tourists indicate a daily intake of acrylamide <150 ng, well below a toxic dose.

  16. A phase space model of Fourier ptychographic microscopy

    PubMed Central

    Horstmeyer, Roarke; Yang, Changhuei

    2014-01-01

    A new computational imaging technique, termed Fourier ptychographic microscopy (FPM), uses a sequence of low-resolution images captured under varied illumination to iteratively converge upon a high-resolution complex sample estimate. Here, we propose a mathematical model of FPM that explicitly connects its operation to conventional ptychography, a common procedure applied to electron and X-ray diffractive imaging. Our mathematical framework demonstrates that under ideal illumination conditions, conventional ptychography and FPM both produce datasets that are mathematically linked by a linear transformation. We hope this finding encourages the future cross-pollination of ideas between two otherwise unconnected experimental imaging procedures. In addition, the coherence state of the illumination source used by each imaging platform is critical to successful operation, yet currently not well understood. We apply our mathematical framework to demonstrate that partial coherence uniquely alters both conventional ptychography’s and FPM’s captured data, but up to a certain threshold can still lead to accurate resolution-enhanced imaging through appropriate computational post-processing. We verify this theoretical finding through simulation and experiment. PMID:24514995

  17. Comparison of a conventional and nested PCR for diagnostic confirmation and genotyping of Orientia tsutsugamushi.

    PubMed

    Janardhanan, Jeshina; Prakash, John Antony Jude; Abraham, Ooriapadickal C; Varghese, George M

    2014-05-01

    A nested polymerase chain reaction (PCR) targeting the 56-kDa antigen gene is currently the most commonly used molecular technique for confirmation of scrub typhus and genotyping of Orientia tsutsugamushi. In this study, we have compared the commonly used nested PCR (N-PCR) with a single-step conventional PCR (C-PCR) for amplification and genotyping. Eschar samples collected from 24 patients with scrub typhus confirmed by IgM enzyme-linked immunosorbent assay were used for DNA extraction following which amplifications were carried out using nested and C-PCR methods. The amplicons were sequenced and compared to other sequences in the database using BLAST. Conventional PCR showed a high positivity rate of 95.8% compared to the 75% observed using N-PCR. On sequence analysis, the N-PCR amplified region showed more variation among strains than the C-PCR amplified region. The C-PCR, which is more economical, provided faster and better results compared to N-PCR. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Preparation of alpha sources using magnetohydrodynamic electrodeposition for radionuclide metrology.

    PubMed

    Panta, Yogendra M; Farmer, Dennis E; Johnson, Paula; Cheney, Marcos A; Qian, Shizhi

    2010-02-01

    Expanded use of nuclear fuel as an energy resource and terrorist threats to public safety clearly require the development of new state-of-the-art technologies and improvement of safety measures to minimize the exposure of people to radiation and the accidental release of radiation into the environment. The precision in radionuclide metrology is currently limited by the source quality rather than the detector performance. Electrodeposition is a commonly used technique to prepare massless radioactive sources. Unfortunately, the radioactive sources prepared by the conventional electrodeposition method produce poor resolution in alpha spectrometric measurements. Preparing radioactive sources with better resolution and higher yield in the alpha spectrometric range by integrating magnetohydrodynamic convection with the conventional electrodeposition technique was proposed and tested by preparing mixed alpha sources containing uranium isotopes ((238)U, (234)U), plutonium ((239)Pu), and americium ((241)Am) for alpha spectrometric determination. The effects of various parameters such as magnetic flux density, deposition current and time, and pH of the sample solution on the formed massless radioactive sources were also experimentally investigated. Copyright 2009 Elsevier Inc. All rights reserved.

  19. Rapid detection of illegal colorants on traditional Chinese pastries through mass spectrometry with an interchangeable thermal desorption electrospray ionization source.

    PubMed

    Chao, Yu-Ying; Chen, Yen-Ling; Chen, Wei-Chu; Chen, Bai-Hsiun; Huang, Yeou-Lih

    2018-06-30

    Ambient mass spectrometry using an interchangeable thermal desorption/electrospray ionization source (TD-ESI) is a relatively new technique that has had only a limited number of applications to date. Nevertheless, this direct-analysis technique has potential for wider use in analytical chemistry (e.g., in the rapid direct detection of contaminants, residues, and adulterants on and in food) when operated in dual-working mode (pretreatment-free qualitative screening and conventional quantitative confirmation) after switching to a TD-ESI source from a conventional ESI source. Herein, we describe the benefits and challenges associated with the use of a TD-ESI source to detect adulterants on traditional Chinese pastries (TCPs), as a proof-of-concept for the detection of illegal colorants. While TD-ESI can offer direct (i.e., without any sample preparation) qualitative screening analyses for TCPs with adequate sensitivity within 30 s, the use of TD-ESI for semi-quantification is applicable only for homogeneous matrices (e.g., tang yuan). Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Programmable Colored Illumination Microscopy (PCIM): A practical and flexible optical staining approach for microscopic contrast enhancement

    NASA Astrophysics Data System (ADS)

    Zuo, Chao; Sun, Jiasong; Feng, Shijie; Hu, Yan; Chen, Qian

    2016-03-01

    Programmable colored illumination microscopy (PCIM) has been proposed as a flexible optical staining technique for microscopic contrast enhancement. In this method, we replace the condenser diaphragm of a conventional microscope with a programmable thin film transistor-liquid crystal display (TFT-LCD). By displaying different patterns on the LCD, numerous established imaging modalities can be realized, such as bright field, dark field, phase contrast, oblique illumination, and Rheinberg illuminations, which conventionally rely on intricate alterations in the respective microscope setups. Furthermore, the ease of modulating both the color and the intensity distribution at the aperture of the condenser opens the possibility to combine multiple microscopic techniques, or even realize completely new methods for optical color contrast staining, such as iridescent dark-field and iridescent phase-contrast imaging. The versatility and effectiveness of PCIM is demonstrated by imaging of several transparent colorless specimens, such as unstained lung cancer cells, diatom, textile fibers, and a cryosection of mouse kidney. Finally, the potentialities of PCIM for RGB-splitting imaging with stained samples are also explored by imaging stained red blood cells and a histological section.

  1. Photoacoustic spectroscopic studies of polycyclic aromatic hydrocarbons

    NASA Astrophysics Data System (ADS)

    Zaidi, Zahid H.; Kumar, Pardeep; Garg, R. K.

    1999-02-01

    Because of their involvement in environmental pollutants, in carcinogenic activity, plastics, pharmaceuticals, synthesis of some laser dyes and presence in interstellar space etc., Polycyclic aromatic hydrocarbons (PAHs) are important. As their structure and properties can be varied systematically, they form a beautiful class of molecules for experimental and quantum chemical investigations. These molecules are being studied for last several years by using conventional spectroscopy. In recent years, Photoacoustic (PA) spectroscopy has emerged as a new non-destructive technique with unique capability and sensitivity. The PA effect is the process of generation of acoustic waves in a sample resulting from the absorption of photons. This technique not only reveals non- radiative transitions but also provides information about forbidden singlet-triplet transitions which are not observed normally by the conventional spectroscopy. The present paper deals with the spectroscopic studies of some PAH molecules by PA spectroscopy in the region 250 - 400 nm. The CNDO/S-CI method is used to calculate the electronic transitions with the optimized geometries. A good agreement is found between the experimental and calculated results.

  2. Revision of laser-induced damage threshold evaluation from damage probability data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bataviciute, Gintare; Grigas, Povilas; Smalakys, Linas

    2013-04-15

    In this study, the applicability of commonly used Damage Frequency Method (DFM) is addressed in the context of Laser-Induced Damage Threshold (LIDT) testing with pulsed lasers. A simplified computer model representing the statistical interaction between laser irradiation and randomly distributed damage precursors is applied for Monte Carlo experiments. The reproducibility of LIDT predicted from DFM is examined under both idealized and realistic laser irradiation conditions by performing numerical 1-on-1 tests. A widely accepted linear fitting resulted in systematic errors when estimating LIDT and its error bars. For the same purpose, a Bayesian approach was proposed. A novel concept of parametricmore » regression based on varying kernel and maximum likelihood fitting technique is introduced and studied. Such approach exhibited clear advantages over conventional linear fitting and led to more reproducible LIDT evaluation. Furthermore, LIDT error bars are obtained as a natural outcome of parametric fitting which exhibit realistic values. The proposed technique has been validated on two conventionally polished fused silica samples (355 nm, 5.7 ns).« less

  3. Helminth Infections by Coprological Examination in Sheep-Dogs and Their Zoonotic Importance.

    PubMed

    Öge, Hatice; Öge, Semih; Özbakış, Gökben; Gürcan, I Safa

    2017-03-01

    This study was conducted to determine the prevalence of gastrointestinal helminths and diagnose the species of important zoonotic helminths in sheep dogs. Firstly, fecal samples were macroscopically examined; subsequently, formalin-ethyl acetate sedimentation and ZnSO4 centrifugal floatation techniques were applied for the examination of helminth eggs. PCR technique was utilized to determine the species of E. granulosus and T. canis in dogs found positive for Taenia spp. and Toxocara spp. Helminth infection was detected in 35.26% of sheep dogs. Taenia spp. was the most common helminth (12.05%), followed by Toxocara spp. (9.38%), Toxascaris leonina (6.25%), and Trichuris spp. (4.2%). The positive results in the E. granulosus and T. canis-specific PCR-based molecular tests were obtained in 14 of the Taenia egg-positive samples and in 5 of the Toxocara egg-positive samples from dogs. This study has suggested that coprophagy and feed raw offal and meat to dogs may be responsible for finding atypical helminth eggs in fecal samples from dogs in the absence of an actual infection. To make the diagnosis of their owned parasites of dogs, E. granulosus and T. canis which have zoonotic importance, feces must be examined by both conventional and copro-PCR techniques. In addition to dogs' feeding habits, other related factors must be taken into account in the epidemiology of helminth infection; thus, precaution and control measures will be more reliable.

  4. Review of in situ derivatization techniques for enhanced bioanalysis using liquid chromatography with mass spectrometry.

    PubMed

    Baghdady, Yehia Z; Schug, Kevin A

    2016-01-01

    Accurate and specific analysis of target molecules in complex biological matrices remains a significant challenge, especially when ultra-trace detection limits are required. Liquid chromatography with mass spectrometry is often the method of choice for bioanalysis. Conventional sample preparation and clean-up methods prior to the analysis of biological fluids such as liquid-liquid extraction, solid-phase extraction, or protein precipitation are time-consuming, tedious, and can negatively affect target recovery and detection sensitivity. An alternative or complementary strategy is the use of an off-line or on-line in situ derivatization technique. In situ derivatization can be incorporated to directly derivatize target analytes in their native biological matrices, without any prior sample clean-up methods, to substitute or even enhance the extraction and preconcentration efficiency of these traditional sample preparation methods. Designed appropriately, it can reduce the number of sample preparation steps necessary prior to analysis. Moreover, in situ derivatization can be used to enhance the performance of the developed liquid chromatography with mass spectrometry-based bioanalysis methods regarding stability, chromatographic separation, selectivity, and ionization efficiency. This review presents an overview of the commonly used in situ derivatization techniques coupled to liquid chromatography with mass spectrometry-based bioanalysis to guide and to stimulate future research. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Space charge distributions in insulating polymers: A new non-contacting way of measurement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marty-Dessus, D., E-mail: marty@laplace.univ-tlse.fr; Ziani, A. C.; Berquez, L.

    2015-04-15

    A new technique for the determination of space charge profiles in insulating polymers is proposed. Based on the evolution of an existing thermal wave technique called Focused Laser Intensity Modulation Method ((F)LIMM), it allows non-contact measurements on thin films exhibiting an internal charge to be studied. An electrostatic model taking into account the new sample-cell geometry proposed was first developed. It has been shown, in particular, that it was theoretically possible to calculate the internal charge from experimental measurements while allowing an evaluation of the air layer appearing between the sample and the electrode when non-contact measurements are performed. Thesemore » predictions were confirmed by an experimental implementation for two thin polymer samples (25 μm-polyvinylidenefluoride and 50 μm-polytetrafluoroethylene (PTFE)) used as tests. In these cases, minimum air-layer thickness was determined with an accuracy of 3% and 20%, respectively, depending on the signal-to-noise ratio during the experimental procedure. In order to illustrate the reachable possibilities of this technique, 2D and 3D cartographies of a negative space charge implanted by electron beam within the PTFE test sample were depicted: like in conventional (F)LIMM, a multidimensional representation of a selectively implanted charge remains possible at a few microns depth, but using a non-contacting way of measurement.« less

  6. Evaluation of PCR Approaches for Detection of Bartonella bacilliformis in Blood Samples.

    PubMed

    Gomes, Cláudia; Martinez-Puchol, Sandra; Pons, Maria J; Bazán, Jorge; Tinco, Carmen; del Valle, Juana; Ruiz, Joaquim

    2016-03-01

    The lack of an effective diagnostic tool for Carrion's disease leads to misdiagnosis, wrong treatments and perpetuation of asymptomatic carriers living in endemic areas. Conventional PCR approaches have been reported as a diagnostic technique. However, the detection limit of these techniques is not clear as well as if its usefulness in low bacteriemia cases. The aim of this study was to evaluate the detection limit of 3 PCR approaches. We determined the detection limit of 3 different PCR approaches: Bartonella-specific 16S rRNA, fla and its genes. We also evaluated the viability of dry blood spots to be used as a sample transport system. Our results show that 16S rRNA PCR is the approach with a lowest detection limit, 5 CFU/μL, and thus, the best diagnostic PCR tool studied. Dry blood spots diminish the sensitivity of the assay. From the tested PCRs, the 16S rRNA PCR-approach is the best to be used in the direct blood detection of acute cases of Carrion's disease. However its use in samples from dry blood spots results in easier management of transport samples in rural areas, a slight decrease in the sensitivity was observed. The usefulness to detect by PCR the presence of low-bacteriemic or asymptomatic carriers is doubtful, showing the need to search for new more sensible techniques.

  7. Rapid diagnostic tests duo as alternative to conventional serological assays for conclusive Chagas disease diagnosis.

    PubMed

    Egüez, Karina E; Alonso-Padilla, Julio; Terán, Carolina; Chipana, Zenobia; García, Wilson; Torrico, Faustino; Gascon, Joaquim; Lozano-Beltran, Daniel-Franz; Pinazo, María-Jesús

    2017-04-01

    Chagas disease is caused by the parasite Trypanosoma cruzi. It affects several million people, mainly in Latin America, and severe cardiac and/or digestive complications occur in ~30% of the chronically infected patients. Disease acute stage is mostly asymptomatic and infection goes undiagnosed. In the chronic phase direct parasite detection is hampered due to its concealed presence and diagnosis is achieved by serological methods, like ELISA or indirect hemagglutination assays. Agreement in at least two tests must be obtained due to parasite wide antigenic variability. These techniques require equipped labs and trained personnel and are not available in distant regions. As a result, many infected people often remain undiagnosed until it is too late, as the two available chemotherapies show diminished efficacy in the advanced chronic stage. Easy-to-use rapid diagnostic tests have been developed to be implemented in remote areas as an alternative to conventional tests. They do not need electricity, nor cold chain, they can return results within an hour and some even work with whole blood as sample, like Chagas Stat-Pak (ChemBio Inc.) and Chagas Detect Plus (InBIOS Inc.). Nonetheless, in order to qualify a rapidly diagnosed positive patient for treatment, conventional serological confirmation is obligatory, which might risk its start. In this study two rapid tests based on distinct antigen sets were used in parallel as a way to obtain a fast and conclusive Chagas disease diagnosis using whole blood samples. Chagas Stat-Pak and Chagas Detect Plus were validated by comparison with three conventional tests yielding 100% sensitivity and 99.3% specificity over 342 patients seeking Chagas disease diagnosis in a reference centre in Sucre (Bolivia). Combined used of RDTs in distant regions could substitute laborious conventional serology, allowing immediate treatment and favouring better adhesion to it.

  8. In silico comparison of the reproducibility of full-arch implant provisional restorations to final restoration between a 3D Scan/CAD/CAM technique and the conventional method.

    PubMed

    Mino, Takuya; Maekawa, Kenji; Ueda, Akihiro; Higuchi, Shizuo; Sejima, Junichi; Takeuchi, Tetsuo; Hara, Emilio Satoshi; Kimura-Ono, Aya; Sonoyama, Wataru; Kuboki, Takuo

    2015-04-01

    The aim of this article was to investigate the accuracy in the reproducibility of full-arch implant provisional restorations to final restorations between a 3D Scan/CAD/CAM technique and the conventional method. We fabricated two final restorations for rehabilitation of maxillary and mandibular complete edentulous area and performed a computer-based comparative analysis of the accuracy in the reproducibility of the provisional restoration to final restoration between a 3D scanning and CAD/CAM (Scan/CAD/CAM) technique and the conventional silicone-mold transfer technique. Final restorations fabricated either by the conventional or Scan/CAD/CAM method were successfully installed in the patient. The total concave/convex volume discrepancy observed with the Scan/CAD/CAM technique was 503.50mm(3) and 338.15 mm(3) for maxillary and mandibular implant-supported prostheses (ISPs), respectively. On the other hand, total concave/convex volume discrepancy observed with the conventional method was markedly high (1106.84 mm(3) and 771.23 mm(3) for maxillary and mandibular ISPs, respectively). The results of the present report suggest that Scan/CAD/CAM method enables a more precise and accurate transfer of provisional restorations to final restorations compared to the conventional method. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  9. A single-gradient junction technique to replace multiple-junction shifts for craniospinal irradiation treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hadley, Austin; Ding, George X., E-mail: george.ding@vanderbilt.edu

    2014-01-01

    Craniospinal irradiation (CSI) requires abutting fields at the cervical spine. Junction shifts are conventionally used to prevent setup error–induced overdosage/underdosage from occurring at the same location. This study compared the dosimetric differences at the cranial-spinal junction between a single-gradient junction technique and conventional multiple-junction shifts and evaluated the effect of setup errors on the dose distributions between both techniques for a treatment course and single fraction. Conventionally, 2 lateral brain fields and a posterior spine field(s) are used for CSI with weekly 1-cm junction shifts. We retrospectively replanned 4 CSI patients using a single-gradient junction between the lateral brain fieldsmore » and the posterior spine field. The fields were extended to allow a minimum 3-cm field overlap. The dose gradient at the junction was achieved using dose painting and intensity-modulated radiation therapy planning. The effect of positioning setup errors on the dose distributions for both techniques was simulated by applying shifts of ± 3 and 5 mm. The resulting cervical spine doses across the field junction for both techniques were calculated and compared. Dose profiles were obtained for both a single fraction and entire treatment course to include the effects of the conventional weekly junction shifts. Compared with the conventional technique, the gradient-dose technique resulted in higher dose uniformity and conformity to the target volumes, lower organ at risk (OAR) mean and maximum doses, and diminished hot spots from systematic positioning errors over the course of treatment. Single-fraction hot and cold spots were improved for the gradient-dose technique. The single-gradient junction technique provides improved conformity, dose uniformity, diminished hot spots, lower OAR mean and maximum dose, and one plan for the entire treatment course, which reduces the potential human error associated with conventional 4-shifted plans.« less

  10. Piezosurgery or conventional rotatory instruments for inferior third molar extractions?

    PubMed

    Piersanti, Luigi; Dilorenzo, Matteo; Monaco, Giuseppe; Marchetti, Claudio

    2014-09-01

    The purpose of this study was to compare the discomfort and surgical outcomes of a piezosurgery device with those of rotatory instruments in lower third molar extraction. A split-mouth, randomized, unblinded clinical study was designed; the 2 molars had to have the same extraction difficulty score. The test side was extracted using a piezosurgery technique and the control side was extracted using a conventional handpiece. The primary endpoint was patient discomfort evaluated with the Postoperative Symptom Severity (PoSSe) scale, which was administered to each patient; secondary endpoints were pain, trismus, swelling, and surgical time evaluation. Paired-samples t test and repeated-measures analysis of variance were used to compare outcomes within patients. Ten consecutive patients (6 female, 4 male; mean age, 22.4 ± 2.3 yr) were recruited. The total score on the PoSSe scale was significantly lower for piezosurgery compared with the conventional rotating handpiece (24.7 ± 10.3 vs 36.0 ± 7.6; t = -4.27; P = .002). Moreover, postoperative swelling 1 week after surgery was significantly lower for piezosurgery than for the conventional rotating handpiece (2.75 ± 0.23 vs 3.1 ± 0.39 cm; t = -2.63; P = .027). Piezosurgery was associated with less postoperative discomfort and yielded better results for swelling. Piezosurgery seems to be a good technique in daily surgical practice, especially if applied in the critical steps in which safety and respect for soft tissue, bone, and nerves are necessary. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  11. A Novel In-Beam Delayed Neutron Counting Technique for Characterization of Special Nuclear Materials

    NASA Astrophysics Data System (ADS)

    Bentoumi, G.; Rogge, R. B.; Andrews, M. T.; Corcoran, E. C.; Dimayuga, I.; Kelly, D. G.; Li, L.; Sur, B.

    2016-12-01

    A delayed neutron counting (DNC) system, where the sample to be analyzed remains stationary in a thermal neutron beam outside of the reactor, has been developed at the National Research Universal (NRU) reactor of the Canadian Nuclear Laboratories (CNL) at Chalk River. The new in-beam DNC is a novel approach for non-destructive characterization of special nuclear materials (SNM) that could enable identification and quantification of fissile isotopes within a large and shielded sample. Despite the orders of magnitude reduction in neutron flux, the in-beam DNC method can be as informative as the conventional in-core DNC for most cases while offering practical advantages and mitigated risk when dealing with large radioactive samples of unknown origin. This paper addresses (1) the qualification of in-beam DNC using a monochromatic thermal neutron beam in conjunction with a proven counting apparatus designed originally for in-core DNC, and (2) application of in-beam DNC to an examination of large sealed capsules containing unknown radioactive materials. Initial results showed that the in-beam DNC setup permits non-destructive analysis of bulky and gamma shielded samples. The method does not lend itself to trace analysis, and at best could only reveal the presence of a few milligrams of 235U via the assay of in-beam DNC total counts. Through analysis of DNC count rates, the technique could be used in combination with other neutron or gamma techniques to quantify isotopes present within samples.

  12. Human varicella zoster virus is not present in the semen of a man affected by chickenpox during the in vitro fertilisation of his wife.

    PubMed

    Chan, D Y L; Lam, K K W; Lau, E Y L; Yeung, W S B; Ng, E H Y

    2017-12-01

    Human varicella zoster virus (VZV) is a member of the herpes virus family and affects humans only. Information about the presence of the virus in the semen samples of men affected by chickenpox is rather limited in the literature. Here, we reported a husband was affected by VZV during in vitro fertilisation treatment of his wife treated in our centre. The semen sample was checked for the presence of VZV by the PCR technique. The PCR result found no detectable viral DNA in the semen sample. The semen sample was then used for conventional IVF insemination and subsequently a healthy baby boy was born. This single case report suggests that the semen sample of men affected by chickenpox may be safe to use for assisted reproduction methods during the VZV infective period. © 2017 Blackwell Verlag GmbH.

  13. Evaluation of the laser-induced breakdown spectroscopy technique for determination of the chemical composition of copper concentrates

    NASA Astrophysics Data System (ADS)

    Łazarek, Łukasz; Antończak, Arkadiusz J.; Wójcik, Michał R.; Drzymała, Jan; Abramski, Krzysztof M.

    2014-07-01

    Laser-induced breakdown spectroscopy (LIBS), like many other spectroscopic techniques, is a comparative method. Typically, in qualitative analysis, synthetic certified standard with a well-known elemental composition is used to calibrate the system. Nevertheless, in all laser-induced techniques, such calibration can affect the accuracy through differences in the overall composition of the chosen standard. There are also some intermediate factors, which can cause imprecision in measurements, such as optical absorption, surface structure and thermal conductivity. In this work the calibration performed for the LIBS technique utilizes pellets made directly from the tested materials (old well-characterized samples). This choice produces a considerable improvement in the accuracy of the method. This technique was adopted for the determination of trace elements in industrial copper concentrates, standardized by conventional atomic absorption spectroscopy with a flame atomizer. A series of copper flotation concentrate samples was analyzed for three elements: silver, cobalt and vanadium. We also proposed a method of post-processing the measurement data to minimize matrix effects and permit reliable analysis. It has been shown that the described technique can be used in qualitative and quantitative analyses of complex inorganic materials, such as copper flotation concentrates. It was noted that the final validation of such methodology is limited mainly by the accuracy of the characterization of the standards.

  14. Comparison of Para-Selles Bailenger/Kop-Color Fumouze, Para-Selles-Iodésine/Kop-Color II Fumouze diagnostic kits with conventional microscopic methods in identifying intestinal parasitic diseases in Senegal.

    PubMed

    Sow, Doudou; Dieng, Yémou; Haouchine, Djamal; Niang, Khadim; Niang, Thiane; Sylla, Khadime; Tine, Roger Clément; Ndiaye, Magatte; Ndiaye, Jean Louis; Faye, Babacar; Faye, Omar; Gaye, Oumar; Dieng, Thérèse; Izri, Arezki

    2017-09-01

    In the context of controlling intestinal parasites, accurate diagnosis is essential. Our objective was to evaluate the performance of new diagnostic kits compared to conventional microscopic methods in identifying intestinal parasites. Faeces collected in rural area in Senegal were subjected to several detection techniques. Thus, the sensitivity, specificity, positive and negative predictive values of new diagnostic techniques were compared to conventional merthiolate-iodine-formalin, conventional Bailenger and modified Ritchie. Furthermore, the kappa coefficient was calculated to evaluate the correlation between the new kit and those of modified Ritchie. Out of the 117 patients examined, 102 presented with a parasite, or prevalence of 87.1%. The Fumouze techniques proved to be as effective as the conventional methods in detecting flagellates and helminths with sensitivities ranging from 97 to 100%. However, conventional techniques were slightly more sensitive in identifying Endolimax nana and Blastocystis hominis . The correlation was nearly perfect (k = 0.83 and 1), respectively between Bailenger Fumouze, Iodesine Fumouze and modified Ritchie in identifying helminths while it was just acceptable (k = 0.27 and 0.28) in identifying B. hominis . The modified Ritchie technique routinely used in our laboratory remains a good diagnostic tool. However, the use of kit techniques was interesting when reading the pellet after concentration and the Colour KOP staining was a considerable contribution to the diagnosis of the vegetative forms. Therefore, it would be interesting to determine the cost of a stool test using Fumouze kit techniques to provide the most cost effective way.

  15. Single-incision Laparoscopic Surgery (SILS) in general surgery: a review of current practice.

    PubMed

    Froghi, Farid; Sodergren, Mikael Hans; Darzi, Ara; Paraskeva, Paraskevas

    2010-08-01

    Single-incision laparoscopic surgery (SILS) aims to eliminate multiple port incisions. Although general operative principles of SILS are similar to conventional laparoscopic surgery, operative techniques are not standardized. This review aims to evaluate the current use of SILS published in the literature by examining the types of operations performed, techniques employed, and relevant complications and morbidity. This review considered a total of 94 studies reporting 1889 patients evaluating 17 different general surgical operations. There were 8 different access techniques reported using conventional laparoscopic instruments and specifically designed SILS ports. There is extensive heterogeneity associated with operating methods and in particular ways of overcoming problems with retraction and instrumentation. Published complications, morbidity, and hospital length of stay are comparable to conventional laparoscopy. Although SILS provides excellent cosmetic results and morbidity seems similar to conventional laparoscopy, larger randomized controlled trials are needed to assess the safety and efficacy of this novel technique.

  16. Analysis of model Titan atmospheric components using ion mobility spectrometry

    NASA Technical Reports Server (NTRS)

    Kojiro, D. R.; Cohen, M. J.; Wernlund, R. F.; Stimac, R. M.; Humphry, D. E.; Takeuchi, N.

    1991-01-01

    The Gas Chromatograph-Ion Mobility Spectrometer (GC-IMS) was proposed as an analytical technique for the analysis of Titan's atmosphere during the Cassini Mission. The IMS is an atmospheric pressure, chemical detector that produces an identifying spectrum of each chemical species measured. When the IMS is combined with a GC as a GC-IMS, the GC is used to separate the sample into its individual components, or perhaps small groups of components. The IMS is then used to detect, quantify, and identify each sample component. Conventional IMS detection and identification of sample components depends upon a source of energetic radiation, such as beta radiation, which ionizes the atmospheric pressure host gas. This primary ionization initiates a sequence of ion-molecule reactions leading to the formation of sufficiently energetic positive or negative ions, which in turn ionize most constituents in the sample. In conventional IMS, this reaction sequence is dominated by the water cluster ion. However, many of the light hydrocarbons expected in Titan's atmosphere cannot be analyzed by IMS using this mechanism at the concentrations expected. Research at NASA Ames and PCP Inc., has demonstrated IMS analysis of expected Titan atmospheric components, including saturated aliphatic hydrocarbons, using two alternate sample ionizations mechanisms. The sensitivity of the IMS to hydrocarbons such as propane and butane was increased by several orders of magnitude. Both ultra dry (waterless) IMS sample ionization and metastable ionization were successfully used to analyze a model Titan atmospheric gas mixture.

  17. Non-Conventional Techniques for the Study of Phase Transitions in NiTi-Based Alloys

    NASA Astrophysics Data System (ADS)

    Nespoli, Adelaide; Villa, Elena; Passaretti, Francesca; Albertini, Franca; Cabassi, Riccardo; Pasquale, Massimo; Sasso, Carlo Paolo; Coïsson, Marco

    2014-07-01

    Differential scanning calorimetry and electrical resistance measurements are the two most common techniques for the study of the phase transition path and temperatures of shape memory alloys (SMA) in stress-free condition. Besides, it is well known that internal friction measurements are also useful for this purpose. There are indeed some further techniques which are seldom used for the basic characterization of SMA transition: dilatometric analysis, magnetic measurements, and Seebeck coefficient study. In this work, we discuss the attitude of these techniques for the study of NiTi-based phase transition. Measurements were conducted on several fully annealed Ni50- x Ti50Cu x samples ranging from 3 to 10 at.% in Cu content, fully annealed at 850 °C for 1 h in vacuum and quenched in water at room temperature. Results show that all these techniques are sensitive to phase transition, and they provide significant information about the existence of intermediate phases.

  18. Detection of clonal evolution in hematopoietic malignancies by combining comparative genomic hybridization and single nucleotide polymorphism arrays.

    PubMed

    Hartmann, Luise; Stephenson, Christine F; Verkamp, Stephanie R; Johnson, Krystal R; Burnworth, Bettina; Hammock, Kelle; Brodersen, Lisa Eidenschink; de Baca, Monica E; Wells, Denise A; Loken, Michael R; Zehentner, Barbara K

    2014-12-01

    Array comparative genomic hybridization (aCGH) has become a powerful tool for analyzing hematopoietic neoplasms and identifying genome-wide copy number changes in a single assay. aCGH also has superior resolution compared with fluorescence in situ hybridization (FISH) or conventional cytogenetics. Integration of single nucleotide polymorphism (SNP) probes with microarray analysis allows additional identification of acquired uniparental disomy, a copy neutral aberration with known potential to contribute to tumor pathogenesis. However, a limitation of microarray analysis has been the inability to detect clonal heterogeneity in a sample. This study comprised 16 samples (acute myeloid leukemia, myelodysplastic syndrome, chronic lymphocytic leukemia, plasma cell neoplasm) with complex cytogenetic features and evidence of clonal evolution. We used an integrated manual peak reassignment approach combining analysis of aCGH and SNP microarray data for characterization of subclonal abnormalities. We compared array findings with results obtained from conventional cytogenetic and FISH studies. Clonal heterogeneity was detected in 13 of 16 samples by microarray on the basis of log2 values. Use of the manual peak reassignment analysis approach improved resolution of the sample's clonal composition and genetic heterogeneity in 10 of 13 (77%) patients. Moreover, in 3 patients, clonal disease progression was revealed by array analysis that was not evident by cytogenetic or FISH studies. Genetic abnormalities originating from separate clonal subpopulations can be identified and further characterized by combining aCGH and SNP hybridization results from 1 integrated microarray chip by use of the manual peak reassignment technique. Its clinical utility in comparison to conventional cytogenetic or FISH studies is demonstrated. © 2014 American Association for Clinical Chemistry.

  19. Strain gage measurement errors in the transient heating of structural components

    NASA Technical Reports Server (NTRS)

    Richards, W. Lance

    1993-01-01

    Significant strain-gage errors may exist in measurements acquired in transient thermal environments if conventional correction methods are applied. Conventional correction theory was modified and a new experimental method was developed to correct indicated strain data for errors created in radiant heating environments ranging from 0.6 C/sec (1 F/sec) to over 56 C/sec (100 F/sec). In some cases the new and conventional methods differed by as much as 30 percent. Experimental and analytical results were compared to demonstrate the new technique. For heating conditions greater than 6 C/sec (10 F/sec), the indicated strain data corrected with the developed technique compared much better to analysis than the same data corrected with the conventional technique.

  20. Identification of exhumed remains of fire tragedy victims using conventional methods and autosomal/Y-chromosomal short tandem repeat DNA profiling.

    PubMed

    Calacal, Gayvelline C; Delfin, Frederick C; Tan, Michelle Music M; Roewer, Lutz; Magtanong, Danilo L; Lara, Myra C; Fortun, Raquel dR; De Ungria, Maria Corazon A

    2005-09-01

    In a fire tragedy in Manila in December 1998, one of the worst tragic incidents which resulted in the reported death of 23 children, identity could not be established initially resulting in the burial of still unidentified bodies. Underscoring the importance of identifying each of the human remains, the bodies were exhumed 3 months after the tragedy. We describe here our work, which was the first national case handled by local laboratories wherein conventional and molecular-based techniques were successfully applied in forensic identification. The study reports analysis of DNA obtained from skeletal remains exposed to conditions of burning, burial, and exhumation. DNA typing methods using autosomal and Y-chromosomal short tandem repeat (Y-STR) markers reinforced postmortem examinations using conventional identification techniques. The strategy resulted in the identification of 18 out of the 21 human remains analyzed, overcoming challenges encountered due to the absence of established procedures for the recovery of mass disaster remains. There was incomplete antemortem information to match the postmortem data obtained from the remains of 3 female child victims. Two victims were readily identified due to the availability of antemortem tissues. In the absence of this biologic material, parentage testing was performed using reference blood samples collected from parents and relatives. Data on patrilineal lineage based on common Y-STR haplotypes augmented autosomal DNA typing, particularly in deficiency cases.

  1. Simple and Fast Sample Preparation Followed by Gas Chromatography-Tandem Mass Spectrometry (GC-MS/MS) for the Analysis of 2- and 4-Methylimidazole in Cola and Dark Beer.

    PubMed

    Choi, Sol Ji; Jung, Mun Yhung

    2017-04-01

    We have developed a simple and fast sample preparation technique in combination with a gas chromatography-tandem mass spectrometry (GC-MS/MS) for the quantification of 2-methylimidazole (2-MeI) and 4-methylimidazole (4-MeI) in colas and dark beers. Conventional sample preparation technique for GC-MS requires laborious and time-consuming steps consisting of sample concentration, pH adjustment, ion pair extraction, centrifugation, back-extraction, centrifugation, derivatization, and extraction. Our sample preparation technique consists of only 2 steps (in situ derivation and extraction) which requires less than 3 min. This method provided high linearity, low limit of detection and limit of quantification, high recovery, and high intra- and interday repeatability. It was found that internal standard method with diluted stable isotope (4-MeI-d 6 ) and 2-ethylimidazole (2-EI) could not correctly compensate the matrix effects. Thus, standard addition technique was used for the quantification of 2- and 4-MeI. The established method was successfully applied to colas and dark beers for the determination of 2-MeI and 4-MeI. The 4-MeI contents in colas and dark beers ranged from 8 to 319 μg/L and from trace to 417 μg/L, respectively. Small quantity (0 to 8 μg/L) of 2-MeI was found only in dark beers. The contents of 4-MeI (22 μg/L) in colas obtained from fast food restaurants were significantly lower than those (177 μg/L) in canned or bottled colas. © 2017 Institute of Food Technologists®.

  2. Feasibility of ballistic strengthening exercises in neurologic rehabilitation.

    PubMed

    Williams, Gavin; Clark, Ross A; Hansson, Jessica; Paterson, Kade

    2014-09-01

    Conventional methods for strength training in neurologic rehabilitation are not task specific for walking. Ballistic strength training was developed to improve the functional transfer of strength training; however, no research has investigated this in neurologic populations. The aim of this pilot study was to evaluate the feasibility of applying ballistic principles to conventional leg strengthening exercises in individuals with mobility limitations as a result of neurologic injuries. Eleven individuals with neurologic injuries completed seated and reclined leg press using conventional and ballistic techniques. A 2 × 2 repeated-measures analysis of variance was used to compare power measures (peak movement height and peak velocity) between exercises and conditions. Peak jump velocity and peak jump height were greater when using the ballistic jump technique rather than the conventional concentric technique (P < 0.01). These findings suggest that when compared with conventional strengthening exercises, the incorporation of ballistic principles was associated with increased peak height and peak velocities.

  3. Semiautomated confocal imaging of fungal pathogenesis on plants: Microscopic analysis of macroscopic specimens.

    PubMed

    Minker, Katharine R; Biedrzycki, Meredith L; Kolagunda, Abhishek; Rhein, Stephen; Perina, Fabiano J; Jacobs, Samuel S; Moore, Michael; Jamann, Tiffany M; Yang, Qin; Nelson, Rebecca; Balint-Kurti, Peter; Kambhamettu, Chandra; Wisser, Randall J; Caplan, Jeffrey L

    2018-02-01

    The study of phenotypic variation in plant pathogenesis provides fundamental information about the nature of disease resistance. Cellular mechanisms that alter pathogenesis can be elucidated with confocal microscopy; however, systematic phenotyping platforms-from sample processing to image analysis-to investigate this do not exist. We have developed a platform for 3D phenotyping of cellular features underlying variation in disease development by fluorescence-specific resolution of host and pathogen interactions across time (4D). A confocal microscopy phenotyping platform compatible with different maize-fungal pathosystems (fungi: Setosphaeria turcica, Cochliobolus heterostrophus, and Cercospora zeae-maydis) was developed. Protocols and techniques were standardized for sample fixation, optical clearing, species-specific combinatorial fluorescence staining, multisample imaging, and image processing for investigation at the macroscale. The sample preparation methods presented here overcome challenges to fluorescence imaging such as specimen thickness and topography as well as physiological characteristics of the samples such as tissue autofluorescence and presence of cuticle. The resulting imaging techniques provide interesting qualitative and quantitative information not possible with conventional light or electron 2D imaging. Microsc. Res. Tech., 81:141-152, 2018. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  4. Reinforcing the role of the conventional C-arm--a novel method for simplified distal interlocking.

    PubMed

    Windolf, Markus; Schroeder, Josh; Fliri, Ladina; Dicht, Benno; Liebergall, Meir; Richards, R Geoff

    2012-01-25

    The common practice for insertion of distal locking screws of intramedullary nails is a freehand technique under fluoroscopic control. The process is technically demanding, time-consuming and afflicted to considerable radiation exposure of the patient and the surgical personnel. A new concept is introduced utilizing information from within conventional radiographic images to help accurately guide the surgeon to place the interlocking bolt into the interlocking hole. The newly developed technique was compared to conventional freehand in an operating room (OR) like setting on human cadaveric lower legs in terms of operating time and radiation exposure. The proposed concept (guided freehand), generally based on the freehand gold standard, additionally guides the surgeon by means of visible landmarks projected into the C-arm image. A computer program plans the correct drilling trajectory by processing the lens-shaped hole projections of the interlocking holes from a single image. Holes can be drilled by visually aligning the drill to the planned trajectory. Besides a conventional C-arm, no additional tracking or navigation equipment is required.Ten fresh frozen human below-knee specimens were instrumented with an Expert Tibial Nail (Synthes GmbH, Switzerland). The implants were distally locked by performing the newly proposed technique as well as the conventional freehand technique on each specimen. An orthopedic resident surgeon inserted four distal screws per procedure. Operating time, number of images and radiation time were recorded and statistically compared between interlocking techniques using non-parametric tests. A 58% reduction in number of taken images per screw was found for the guided freehand technique (7.4 ± 3.4) (mean ± SD) compared to the freehand technique (17.6 ± 10.3) (p < 0.001). Total radiation time (all 4 screws) was 55% lower for the guided freehand technique compared to conventional freehand (p = 0.001). Operating time per screw (from first shot to screw tightened) was on average 22% reduced by guided freehand (p = 0.018). In an experimental setting, the newly developed guided freehand technique for distal interlocking has proven to markedly reduce radiation exposure when compared to the conventional freehand technique. The method utilizes established clinical workflows and does not require cost intensive add-on devices or extensive training. The underlying principle carries potential to assist implant positioning in numerous other applications within orthopedics and trauma from screw insertions to placement of plates, nails or prostheses.

  5. Manufacturing implant supported auricular prostheses by rapid prototyping techniques.

    PubMed

    Karatas, Meltem Ozdemir; Cifter, Ebru Demet; Ozenen, Didem Ozdemir; Balik, Ali; Tuncer, Erman Bulent

    2011-08-01

    Maxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to. Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid prototyping techniques have been developed for extraoral prosthesis in order to reduce these disadvantages of conventional methods. Rapid prototyping technique has the potential to simplify the procedure and decrease the laboratory work required. It eliminates the need for measurement impression procedures and preparation of wax model to be performed by prosthodontists themselves In the near future this technology will become a standard for fabricating maxillofacial prostheses.

  6. Simulation of a compact analyzer-based imaging system with a regular x-ray source

    NASA Astrophysics Data System (ADS)

    Caudevilla, Oriol; Zhou, Wei; Stoupin, Stanislav; Verman, Boris; Brankov, J. G.

    2017-03-01

    Analyzer-based Imaging (ABI) belongs to a broader family of phase-contrast (PC) X-ray techniques. PC measures X-ray deflection phenomena when interacting with a sample, which is known to provide higher contrast images of soft tissue than other X-ray methods. This is of high interest in the medical field, in particular for mammogram applications. This paper presents a simulation tool for table-top ABI systems using a conventional polychromatic X-ray source.

  7. Tomographic diffractive microscopy with agile illuminations for imaging targets in a noisy background.

    PubMed

    Zhang, T; Godavarthi, C; Chaumet, P C; Maire, G; Giovannini, H; Talneau, A; Prada, C; Sentenac, A; Belkebir, K

    2015-02-15

    Tomographic diffractive microscopy is a marker-free optical digital imaging technique in which three-dimensional samples are reconstructed from a set of holograms recorded under different angles of incidence. We show experimentally that, by processing the holograms with singular value decomposition, it is possible to image objects in a noisy background that are invisible with classical wide-field microscopy and conventional tomographic reconstruction procedure. The targets can be further characterized with a selective quantitative inversion.

  8. Applications of synchrotron μ-XRF to study the distribution of biologically important elements in different environmental matrices: a review.

    PubMed

    Majumdar, Sanghamitra; Peralta-Videa, Jose R; Castillo-Michel, Hiram; Hong, Jie; Rico, Cyren M; Gardea-Torresdey, Jorge L

    2012-11-28

    Environmental matrices including soils, sediments, and living organisms are reservoirs of several essential as well as non-essential elements. Accurate qualitative and quantitative information on the distribution and interaction of biologically significant elements is vital to understand the role of these elements in environmental and biological samples. Synchrotron micro-X-ray fluorescence (μ-SXRF) allows in situ mapping of biologically important elements at nanometer to sub-micrometer scale with high sensitivity, negligible sample damage and enable tuning of the incident energy as desired. Beamlines in the synchrotron facilities are rapidly increasing their analytical versatility in terms of focusing optics, detector technologies, incident energy, and sample environment. Although extremely competitive, it is now feasible to find stations offering complimentary techniques like micro-X-ray diffraction (μ-XRD) and micro-X-ray absorption spectroscopy (μ-XAS) that will allow a more complete characterization of complex matrices. This review includes the most recent literature on the emerging applications and challenges of μ-SXRF in studying the distribution of biologically important elements and manufactured nanoparticles in soils, sediments, plants, and microbes. The advantages of using μ-SXRF and complimentary techniques in contrast to conventional techniques used for the respective studies are discussed. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Accurate Quantitation and Analysis of Nitrofuran Metabolites, Chloramphenicol, and Florfenicol in Seafood by Ultrahigh-Performance Liquid Chromatography-Tandem Mass Spectrometry: Method Validation and Regulatory Samples.

    PubMed

    Aldeek, Fadi; Hsieh, Kevin C; Ugochukwu, Obiadada N; Gerard, Ghislain; Hammack, Walter

    2018-05-23

    We developed and validated a method for the extraction, identification, and quantitation of four nitrofuran metabolites, 3-amino-2-oxazolidinone (AOZ), 3-amino-5-morpholinomethyl-2-oxazolidinone (AMOZ), semicarbazide (SC), and 1-aminohydantoin (AHD), as well as chloramphenicol and florfenicol in a variety of seafood commodities. Samples were extracted by liquid-liquid extraction techniques, analyzed by ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), and quantitated using commercially sourced, derivatized nitrofuran metabolites, with their isotopically labeled internal standards in-solvent. We obtained recoveries of 90-100% at various fortification levels. The limit of detection (LOD) was set at 0.25 ng/g for AMOZ and AOZ, 1 ng/g for AHD and SC, and 0.1 ng/g for the phenicols. Various extraction methods, standard stability, derivatization efficiency, and improvements to conventional quantitation techniques were also investigated. We successfully applied this method to the identification and quantitation of nitrofuran metabolites and phenicols in 102 imported seafood products. Our results revealed that four of the samples contained residues from banned veterinary drugs.

  10. A Review of Current Methods for Analysis of Mycotoxins in Herbal Medicines

    PubMed Central

    Zhang, Lei; Dou, Xiao-Wen; Zhang, Cheng; Logrieco, Antonio F.; Yang, Mei-Hua

    2018-01-01

    The presence of mycotoxins in herbal medicines is an established problem throughout the entire world. The sensitive and accurate analysis of mycotoxin in complicated matrices (e.g., herbs) typically involves challenging sample pretreatment procedures and an efficient detection instrument. However, although numerous reviews have been published regarding the occurrence of mycotoxins in herbal medicines, few of them provided a detailed summary of related analytical methods for mycotoxin determination. This review focuses on analytical techniques including sampling, extraction, cleanup, and detection for mycotoxin determination in herbal medicines established within the past ten years. Dedicated sections of this article address the significant developments in sample preparation, and highlight the importance of this procedure in the analytical technology. This review also summarizes conventional chromatographic techniques for mycotoxin qualification or quantitation, as well as recent studies regarding the development and application of screening assays such as enzyme-linked immunosorbent assays, lateral flow immunoassays, aptamer-based lateral flow assays, and cytometric bead arrays. The present work provides a good insight regarding the advanced research that has been done and closes with an indication of future demand for the emerging technologies. PMID:29393905

  11. Determination of Coreceptor Usage of Human Immunodeficiency Virus Type 1 from Patient Plasma Samples by Using a Recombinant Phenotypic Assay

    PubMed Central

    Trouplin, Virginie; Salvatori, Francesca; Cappello, Fanny; Obry, Veronique; Brelot, Anne; Heveker, Nikolaus; Alizon, Marc; Scarlatti, Gabriella; Clavel, François; Mammano, Fabrizio

    2001-01-01

    We developed a recombinant virus technique to determine the coreceptor usage of human immunodeficiency virus type 1 (HIV-1) from plasma samples, the source expected to represent the most actively replicating virus population in infected subjects. This method is not subject to selective bias associated with virus isolation in culture, a step required for conventional tropism determination procedures. The addition of a simple subcloning step allowed semiquantitative evaluation of virus populations with a different coreceptor (CCR5 or CXCR4) usage specificity present in each plasma sample. This procedure detected mixtures of CCR5- and CXCR4-exclusive virus populations as well as dualtropic viral variants, in variable proportions. Sequence analysis of dualtropic clones indicated that changes in the V3 loop are necessary for the use of CXCR4 as a coreceptor, but the overall context of the V1-V3 region is important to preserve the capacity to use CCR5. This convenient technique can greatly assist the study of virus evolution and compartmentalization in infected individuals. PMID:11119595

  12. Determination of ABO blood grouping from human oral squamous epithelium by the highly sensitive immunohistochemical staining method EnVision+.

    PubMed

    Noda, Hiroshi; Yokota, Makoto; Tatsumi, Shinji; Sugiyama, Shizuyuki

    2002-03-01

    Using the highly sensitive immunohistochemical staining method EnVision+, which employs a dextran polymer reagent for the secondary antibody, the detection of the ABH antigens was attempted in the oral squamous epithelium. This new technique uses monoclonal antibody as a primary antibody and it takes about three hours for staining. The time is much shorter than conventional absorption-elution testing or absorption-inhibition testing for the determination of ABO blood grouping. Secretor saliva samples were stained at strong intensity by the antibody, which corresponded to its blood group and anti-H. On the one hand, nonsecretor saliva samples were stained at strong intensity only by the antibody that corresponded to its blood group, and at weak intensity only by anti-H. Since human oral squamous epithelium antigens were stained specifically by this method, we can examine the ABO blood group of saliva samples and perform cytodiagnosis at the same time. Our research suggested that the EnVision+ Method is a useful technique for ABO blood grouping of saliva in forensic cases.

  13. A Review of Mid-Infrared and Near-Infrared Imaging: Principles, Concepts and Applications in Plant Tissue Analysis.

    PubMed

    Türker-Kaya, Sevgi; Huck, Christian W

    2017-01-20

    Plant cells, tissues and organs are composed of various biomolecules arranged as structurally diverse units, which represent heterogeneity at microscopic levels. Molecular knowledge about those constituents with their localization in such complexity is very crucial for both basic and applied plant sciences. In this context, infrared imaging techniques have advantages over conventional methods to investigate heterogeneous plant structures in providing quantitative and qualitative analyses with spatial distribution of the components. Thus, particularly, with the use of proper analytical approaches and sampling methods, these technologies offer significant information for the studies on plant classification, physiology, ecology, genetics, pathology and other related disciplines. This review aims to present a general perspective about near-infrared and mid-infrared imaging/microspectroscopy in plant research. It is addressed to compare potentialities of these methodologies with their advantages and limitations. With regard to the organization of the document, the first section will introduce the respective underlying principles followed by instrumentation, sampling techniques, sample preparations, measurement, and an overview of spectral pre-processing and multivariate analysis. The last section will review selected applications in the literature.

  14. Comparison of Kato-Katz, ethyl-acetate sedimentation, and Midi Parasep® in the diagnosis of hookworm, Ascaris and Trichuris infections in the context of an evaluation of rural sanitation in India.

    PubMed

    Funk, Anna L; Boisson, Sophie; Clasen, Thomas; Ensink, Jeroen H J

    2013-06-01

    The Kato-Katz, conventional ethyl-acetate sedimentation, and Midi Parasep(®) methods for diagnosing infection with soil-transmitted helminths were compared. The Kato-Katz technique gave the best overall diagnostic performance with the highest results in all measures (prevalence, faecal egg count, sensitivity) followed by the conventional ethyl-acetate and then the Midi Parasep(®) technique. The Kato-Katz technique showed a significantly higher faecal egg count and sensitivity for both hookworm and Trichuris as compared to the Midi Parasep(®) technique. The conventional ethyl-acetate technique produced smaller pellets and showed lower pellet mobility as compared to the Midi Parasep(®). Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Advances in photo-thermal infrared imaging microspectroscopy

    NASA Astrophysics Data System (ADS)

    Furstenberg, Robert; Kendziora, Chris; Papantonakis, Michael; Nguyen, Viet; McGill, Andrew

    2013-05-01

    There is a growing need for chemical imaging techniques in many fields of science and technology: forensics, materials science, pharmaceutical and chemical industries, just to name a few. While FTIR micro-spectroscopy is commonly used, its practical resolution limit of about 20 microns or more is often insufficient. Raman micro-spectroscopy provides better spatial resolution (~1 micron), but is not always practical because of samples exhibiting fluorescence or low Raman scattering efficiency. We are developing a non-contact and non-destructive technique we call photo-thermal infrared imaging spectroscopy (PT-IRIS). It involves photo-thermal heating of the sample with a tunable quantum cascade laser and measuring the resulting increase in thermal emission with an infrared detector. Photo-thermal emission spectra resemble FTIR absorbance spectra and can be acquired in both stand-off and microscopy configurations. Furthermore, PT-IRIS allows the acquisition of absorbance-like photo-thermal spectra in a reflected geometry, suitable for field applications and for in-situ study of samples on optically IR-opaque substrates (metals, fabrics, paint, glass etc.). Conventional FTIR microscopes in reflection mode measure the reflectance spectra which are different from absorbance spectra and are usually not catalogued in FTIR spectral libraries. In this paper, we continue developing this new technique. We perform a series of numerical simulations of the laser heating of samples during photo-thermal microscopy. We develop parameterized formulas to help the user pick the appropriate laser illumination power. We also examine the influence of sample geometry on spectral signatures. Finally, we measure and compare photo-thermal and reflectance spectra for two test samples.

  16. Headspace solid-phase microextraction for the determination of volatile and semi-volatile pollutants in water and air.

    PubMed

    Llompart, M; Li, K; Fingas, M

    1998-10-16

    In this work we report the use of solid-phase microextraction (SPME) to extract and concentrate water-soluble volatile as well as semi-volatile pollutants. Both methods of exposing the SPME fibre were utilised: immersion in the aqueous solution (SPME) and in the headspace over the solution (HSSPME). The proposed HSSPME procedure was compared to conventional static headspace (HS) analysis for artificially spiked water as well as real water samples, which had been, equilibrated with various oil and petroleum products. Both techniques gave similar results but HSSPME was much more sensitive and exhibited better precision. Detection limits were found to be in the sub-ng/ml level, with precision better than 5% R.S.D. in most cases. To evaluate the suitability of SPME for relatively high contamination level analysis, the proposed HSSPME method was applied to the screening of run-off water samples that had heavy oil suspended in them from a tire fire incident. HSSPME results were compared with liquid--liquid extraction. Library searches were conducted on the resulting GC-MS total ion chromatograms to determine the types of compounds found in such samples. Both techniques found similar composition in the water samples with the exception of alkylnaphthalenes that were detected only by HSSPME. A brief study was carried out to assess using SPME for air monitoring. By sampling and concentrating the volatile organic compounds in the coating of the SPME fibre without any other equipment, this new technique is useful as an alternative to active air monitoring by means of sampling pumps and sorbent tubes.

  17. Occlusal contact of fixed implant prostheses using functional bite impression technique.

    PubMed

    Suzuki, Yasunori; Shimpo, Hidemasa; Ohkubo, Chikahiro

    2015-02-01

    Functional bite impression (FBI) has been described as a definitive impression made under occlusal force after functional generated path (FGP) recording. This study compared the accuracy of occlusal contact of implant-fixed prostheses using the FBI technique and the conventional impression technique. Twelve subjects, each missing a single premolar or molar, were selected for this study. The conditions of the occlusal contacts were identified by the modified transillumination method. The occlusal contact condition was determined by comparing the rate of change in the occlusal contact area of the implant-fixed prostheses and both adjacent teeth before and after occlusal adjustment. The rate of change in the occlusal contact area using the FBI technique was 96%, and the rate using the conventional technique was 54%. The occlusal contact of implant prostheses using the FBI technique revealed better accuracy than that of the conventional technique. Regarding the FBI technique, a precise and functional prosthesis could be produced by completing the maxillomandibular registration, impression, and FGP at the same time.

  18. Software breadboard study

    NASA Technical Reports Server (NTRS)

    Nuckolls, C.; Frank, Mark

    1990-01-01

    The overall goal of this study was to develop new concepts and technology for the Comet Rendezvous Asteroid Flyby (CRAF), Cassini, and other future deep space missions which maximally conform to the Functional Specification for the NASA X-Band Transponder (NXT), FM513778 (preliminary, revised July 26, 1988). The study is composed of two tasks. The first task was to investigate a new digital signal processing technique which involves the processing of 1-bit samples and has the potential for significant size, mass, power, and electrical performance improvements over conventional analog approaches. The entire X-band receiver tracking loop was simulated on a digital computer using a high-level programming language. Simulations on this 'software breadboard' showed the technique to be well-behaved and a good approximation to its analog predecessor from threshold to strong signal levels in terms of tracking-loop performance, command signal-to-noise ratio and ranging signal-to-noise ratio. The successful completion of this task paves the way for building a hardware breadboard, the recommended next step in confirming this approach is ready for incorporation into flight hardware. The second task in this study was to investigate another technique which provides considerable simplification in the synthesis of the receiver first LO over conventional phase-locked multiplier schemes and in this approach, provides down-conversion for an S-band emergency receive mode without the need of an additional LO. The objective of this study was to develop methodology and models to predict the conversion loss, input RF bandwidth, and output RF bandwidth of a series GaAs FET sampling mixer and to breadboard and test a circuit design suitable for the X and S-band down-conversion applications.

  19. Immuno Nanosensor for the Ultrasensitive Naked Eye Detection of Tuberculosis.

    PubMed

    Mohd Bakhori, Noremylia; Yusof, Nor Azah; Abdullah, Jaafar; Wasoh, Helmi; Md Noor, Siti Suraiya; Ahmad Raston, Nurul Hanun; Mohammad, Faruq

    2018-06-14

    In the present study, a beneficial approach for the ultrasensitive and affordable naked eye detection and diagnosis of tuberculosis (TB) by utilizing plasmonic enzyme-linked immunosorbent assay (ELISA) via antibody-antigen interaction was studied. Here, the biocatalytic cycle of the intracellular enzymes links to the formation and successive growth of the gold nanoparticles (GNPs) for ultrasensitive detection. The formation of different colored solutions by the plasmonic nanoparticles in the presence of enzyme labels links directly to the existence or non-existence of the TB analytes in the sample solutions. For disease detection, the adapted protocol is based mainly on the conventional ELISA procedure that involves catalase-labeled antibodies, i.e., the enzymes consume hydrogen peroxide and further produce GNPs with the addition of gold (III) chloride. The amount of hydrogen peroxide remaining in the solution determines whether the GNPs solution is to be formed in the color blue or the color red, as it serves as a confirmation for the naked eye detection of TB analytes. However, the conventional ELISA method only shows tonal colors that need a high concentration of analyte to achieve high confidence levels for naked eye detection. Also, in this research, we proposed the incorporation of protein biomarker, Mycobacterium tuberculosis ESAT-6-like protein esxB (CFP-10), as a means of TB detection using plasmonic ELISA. With the use of this technique, the CFP-10 detection limit can be lowered to 0.01 µg/mL by the naked eye. Further, our developed technique was successfully tested and confirmed with sputum samples from patients diagnosed with positive TB, thereby providing enough evidence for the utilization of our technique in the early diagnosis of TB disease.

  20. Ultrathin Silicon Sheet in the Management of Unilateral Post-traumatic Temporo-Mandibuar Joint Ankylosis in Children: A Good Alternative to Conventional Techniques.

    PubMed

    Aggarwal, Sushil Kumar; Ankur, Bhatnagar; Jain, R K

    2015-09-01

    We have described a new technique of using ultra-thin silicon sheet (0.2 mm) between two transected bony ends for temporo-mandibular joint (TMJ) ankylosis in children with advantages of short operative time, minimal foreign material insertion and faster recovery time post-operatively which makes our technique a good alternative to conventional techniques. Our study is a non-randomized prospective study conducted on 10 children aged between 4 and 15 years who presented to our tertiary care institute with severe trismus after traumatic injury and were willing to undergo this new technique. The main outcome measure taken into consideration was difference between pre-operative, intra-operative (on table) and post-operative mouth opening (minimum 2 years follow-up). The pre-operative mouth opening in our cases varied from 1 to 5 mm. The intra-operative mouth opening achieved ranged from 2.8 to 3.2 cm. The mouth opening was about more than 2.7 cm in all our cases at 2 years of follow-up. Our technique is a good alternative to conventional techniques used for TMJ ankylosis in children but few more randomized controlled trials are required to assess its effectiveness in comparison to conventional techniques and for universal adoption of this technique.

Top