Sample records for conventional sterilization methods

  1. Selection of biological indicator for validating microwave heating sterilization.

    PubMed

    Sasaki, K; Mori, Y; Honda, W; Miyake, Y

    1998-01-01

    For the purpose of selecting an appropriate biological indicator for evaluation of the effects of microwave heating sterilization, we examined aerobic bacterial spores to determine whether microwaves have non-thermal sterilization effects. After microwave irradiation on dry bacterial spores (three species), none of the bacterial spores were killed. The survival rate of the spores after microwave irradiation of spore suspensions (twelve species) was compared with that after heating by a conventional method. The order of heat resistance in the bacterial species was similar between the two heating methods. Bacillus stearothermophilus spores were the most heat-resistant. These results suggest that microwaves have no non-thermal sterilization effects on bacterial spores, the specific resistant spores to microwave heating, and microwave heating sterilization can be evaluated in the same way as for conventional heating sterilization. As a biological indicator for evaluation of overkill sterilization, B. stearothermophilus spores may be appropriate for microwave heating sterilization as well as steam sterilization.

  2. Application of a Dense Gas Technique for Sterilizing Soft Biomaterials

    PubMed Central

    Karajanagi, Sandeep S.; Yoganathan, Roshan; Mammucari, Raffaella; Park, Hyoungshin; Cox, Julian; Zeitels, Steven M.; Langer, Robert; Foster, Neil R.

    2017-01-01

    Sterilization of soft biomaterials such as hydrogels is challenging because existing methods such as gamma irradiation, steam sterilization, or ethylene oxide sterilization, while effective at achieving high sterility assurance levels (SAL), may compromise their physicochemical properties and biocompatibility. New methods that effectively sterilize soft biomaterials without compromising their properties are therefore required. In this report, a dense-carbon dioxide (CO2)-based technique was used to sterilize soft polyethylene glycol (PEG)-based hydrogels while retaining their structure and physicochemical properties. Conventional sterilization methods such as gamma irradiation and steam sterilization severely compromised the structure of the hydrogels. PEG hydrogels with high water content and low elastic shear modulus (a measure of stiffness) were deliberately inoculated with bacteria and spores and then subjected to dense CO2. The dense CO2-based methods effectively sterilized the hydrogels achieving a SAL of 10−7 without compromising the viscoelastic properties, pH, water-content, and structure of the gels. Furthermore, dense CO2-treated gels were biocompatible and non-toxic when implanted subcutaneously in ferrets. The application of novel dense CO2-based methods to sterilize soft biomaterials has implications in developing safe sterilization methods for soft biomedical implants such as dermal fillers and viscosupplements. PMID:21337339

  3. The challenges of heat sterilization of peritoneal dialysis solutions: is there an alternative?

    PubMed

    Hanrahan, Conor T; Himmele, Rainer; Diaz-Buxo, Jose A

    2012-01-01

    Peritoneal dialysis (PD) solutions are currently sterilized in an autoclave using high-temperature saturated steam. Although thermal methods are an effective means of sterilization, the heating of PD solutions results in the formation of toxic glucose degradation products (GDPs). Here, we review basic concepts in the sterilization of PD solutions and discuss possible alternatives to steam sterilization, including filtration, ohmic heat, ionizing radiation, and pulsed ultraviolet light. Although the latter methods have several advantages, many also have prohibitive limitations or have not been adequately studied for use on PD solutions. Thus, in the absence of suitable alternatives, conventional heat sterilization, in combination with low-GDP manufacturing practices, remains the best option at the present time.

  4. Sterilization of silicone-based hydrogels for biomedical application using ozone gas: Comparison with conventional techniques.

    PubMed

    Galante, Raquel; Ghisleni, Daniela; Paradiso, Patrizia; Alves, Vitor D; Pinto, Terezinha J A; Colaço, Rogério; Serro, Ana Paula

    2017-09-01

    Sterilization of hydrogels is challenging due to their often reported sensitivity to conventional methods involving heat or radiation. Although aseptic manufacturing is a possibility, terminal sterilization is safer in biological terms, leading to a higher overall efficiency, and thus should be used whenever it is possible. The main goal of this work was to study the applicability of an innovative ozone gas terminal sterilization method for silicone-based hydrogels and compare its efficacy and effects with those of traditional sterilization methods: steam heat and gamma irradiation. Ozone gas sterilization is a method with potential interest since it is reported as a low cost green method, does not leave toxic residues and can be applied to thermosensitive materials. A hydrogel intended for ophthalmological applications, based on tris(trimethylsiloxy)silyl] propyl methacrylate, was prepared and extensively characterized before and after the sterilization procedures. Alterations regarding transparency, swelling, wettability, ionic permeability, friction coefficient, mechanical properties, topography and morphology and chemical composition were monitored. Efficacy of the ozonation was accessed by performing controlled contaminations and sterility tests. In vitro cytotoxicity testes were also performed. The results show that ozonation may be applied to sterilize the studied material. A treatment with 8 pulses allowed sterilizing the material with bioburdens≤10 3 CFU/mL, preserving all the studied properties within the required known values for contact lenses materials. However, a higher exposure (10 pulses) led to some degradation of the material and induced mild cytotoxicity. Steam heat sterilization led to an increase of swelling capacity and a decrease of the water contact angle. Regarding gamma irradiation, the increase of irradiation dose led to an increase of the friction coefficient. The higher dose (25kGy) originated surface degradation and affected the mechanical properties of the hydrogel by inducing a significant increase of the Young's modulus. Overall, the results show that ozonation may be considered as a valid and promising alternative for the sterilization of silicon-based hydrogels for biomedical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. A sterilization system using ultraviolet photochemical reactions based on nitrous oxide and oxygen gases.

    PubMed

    Ohnishi, Yasutaka; Matsumoto, Hiroyuki; Iwamori, Satoru

    2016-03-01

    Active oxygen species (AOS) generated under ultraviolet (UV) lamps can be applied for various industrial processes owing to extremely strong oxidative abilities. We have already reported on an application of the AOS for a sterilization process of microorganisms. Here, a sterilization method using active oxygen generated under ultraviolet (UV) lamps introducing nitrous oxide (N2O) and oxygen gases into a vacuum chamber was investigated. Nitrogen dioxide (NO2) gas was readily produced from N2O by UV photochemical reactions under the low-pressure mercury lamp and then used to sterilize medical devices. We compared the ability of the N2O gas to sterilize Geobacillus stearothermophilus spores with those of conventional methods. Successful sterilization of spores on various biological indicators was achieved within 60 min, not only in sterilization bags but also in a lumen device. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. A quick and effective method of limb preparation with health, safety and efficiency benefits.

    PubMed

    Naderi, N; Maw, K; Thomas, M; Boyce, D E; Shokrollahi, K

    2012-03-01

    Pre-operative limb preparation (PLP) usually involves lifting the limb and holding it in a fixed 'static' posture for several minutes. This is hazardous to theatre staff. Furthermore, 'painting' the limb can be time consuming and difficult areas such as between toes and fingers may remain unsterile. We demonstrate the time efficiency and asepsis achieved using the 'sterile bag' preparation technique. An additional advantage is the ability to prepare and anaesthetise a limb prior to theatre, increasing efficiency substantially for units with a large throughput of cases, such as day-case hand surgery lists. We monitored the duration of PLP in 20 patients using the 'sterile bag' technique compared to 20 patients using a conventional 'painting' method. Additionally, microbiology samples acquired from prepared upper limbs of 27 sequential patients operated on by a single surgeon over a two-month period were sent for culture immediately prior to commencement of surgery. The mean duration of the 'sterile bag' PLP was significantly lower than that of the conventional method (24 seconds vs 85 seconds, p=0.045). The technique can take as little as ten seconds (n=1). Final microbiology reports showed no growth for any of the 27 patients from whom a culture sample was taken. The sterile bag technique is effective in achieving asepsis, has the potential to increase theatre efficiency and reduces manual handling hazards compared to the conventional method. It is now taught to all theatre staff in our hospital during manual handling training. It can be undertaken in approximately ten seconds with practice for the upper limb.

  7. Mechanical properties of acellular mouse lungs after sterilization by gamma irradiation.

    PubMed

    Uriarte, Juan J; Nonaka, Paula N; Campillo, Noelia; Palma, Renata K; Melo, Esther; de Oliveira, Luis V F; Navajas, Daniel; Farré, Ramon

    2014-12-01

    Lung bioengineering using decellularized organ scaffolds is a potential alternative for lung transplantation. Clinical application will require donor scaffold sterilization. As gamma-irradiation is a conventional method for sterilizing tissue preparations for clinical application, the aim of this study was to evaluate the effects of lung scaffold sterilization by gamma irradiation on the mechanical properties of the acellular lung when subjected to the artificial ventilation maneuvers typical within bioreactors. Twenty-six mouse lungs were decellularized by a sodium dodecyl sulfate detergent protocol. Eight lungs were used as controls and 18 of them were submitted to a 31kGy gamma irradiation sterilization process (9 kept frozen in dry ice and 9 at room temperature). Mechanical properties of acellular lungs were measured before and after irradiation. Lung resistance (RL) and elastance (EL) were computed by linear regression fitting of recorded signals during mechanical ventilation (tracheal pressure, flow and volume). Static (Est) and dynamic (Edyn) elastances were obtained by the end-inspiratory occlusion method. After irradiation lungs presented higher values of resistance and elastance than before irradiation: RL increased by 41.1% (room temperature irradiation) and 32.8% (frozen irradiation) and EL increased by 41.8% (room temperature irradiation) and 31.8% (frozen irradiation). Similar increases were induced by irradiation in Est and Edyn. Scanning electron microscopy showed slight structural changes after irradiation, particularly those kept frozen. Sterilization by gamma irradiation at a conventional dose to ensure sterilization modifies acellular lung mechanics, with potential implications for lung bioengineering. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. The use of spore strips for monitoring the sterilization of bottled fluids.

    PubMed Central

    Selkon, J. B.; Sisson, P. R.; Ingham, H. R.

    1979-01-01

    A bacterial spore test has been developed which enables the efficacy of the sterilizing cycle recommended by the British Pharmaceutical Codex (1973) for bottled fluids to be accurately monitored. During a 14-month period this test detected faults in 3.3% of the sterilizing cycles, representing five distinct episodes of sterilization failure that passed unnoticed by the conventional controls of physical measurements and sterility testing. There were no failures of sterilization as detected by conventional techniques which were not indicated by the spore test. PMID:458140

  9. Evaluation of Penicillium digitatum sterilization using non-equilibrium atmospheric pressure plasma by terahertz time-domain spectroscopy

    NASA Astrophysics Data System (ADS)

    Hiraoka, Takehiro; Ebizuka, Noboru; Takeda, Keigo; Ohta, Takayuki; Kondo, Hiroki; Ishikawa, Kenji; Kawase, Kodo; Ito, Masafumi; Sekine, Makoto; Hori, Masaru

    2011-10-01

    Recently, the plasma sterilization has attracted much attention as a new sterilization technique that takes the place of spraying agricultural chemicals. The conventional methods for sterilization evaluation, was demanded to culture the samples for several days after plasma treatment. Then, we focused on Terahertz time-domain spectroscopy (THz-TDS). At the THz region, vibrational modes of biological molecules and fingerprint spectra of biologically-relevant molecules were also observed. In this study, our purpose was measurement of the fingerprint spectrum of the Penicillium digitatum (PD) spore and establishment of sterilization method by THz-TDS. The sample was 40mg/ml PD spore suspensions which dropped on cover glass. The atmospheric pressure plasma generated under the conditions which Ar gas flow was 3slm, and alternating voltage of 6kV was applied. The samples were exposed the plasma from 10mm distance for 10 minutes. We could obtain the fingerprint spectrum of the PD spore from 0.5 to 0.9THz. This result indicated the possibility of in-situ evaluation for PD sterilization using THz-TDS.

  10. A novel steam explosion sterilization improving solid-state fermentation performance.

    PubMed

    Zhao, Zhi-Min; Wang, Lan; Chen, Hong-Zhang

    2015-09-01

    Traditional sterilization of solid medium (SM) requires lengthy time, degrades nutrients, and even sterilizes inadequately compared with that of liquid medium due to its low thermal conductivity. A novel sterilization strategy, high-temperature and short-time steam explosion (SE), was exploited for SM sterilization in this study. Results showed that SE conditions for complete sterilization were 172 °C for 2 min and 128 °C for 5 min. Glucose and xylose contents in medium after SE sterilization increased by 157% and 93% respectively compared with those after conventional sterilization (121 °C, 20 min) while fermentation inhibitors were not detected. FTIR spectra revealed that the mild SE conditions helped to release monosaccharides from the polysaccharides. Bacillus subtilis fermentation productivity on medium after SE sterilization was 3.83 times of that after conventional sterilization. Therefore, SE shortened sterilization time and improved SM nutrition, which facilitated fermentability of SM and should promote economy of solid-state fermentation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Effects of sterilization treatments on the analysis of TOC in water samples.

    PubMed

    Shi, Yiming; Xu, Lingfeng; Gong, Dongqin; Lu, Jun

    2010-01-01

    Decomposition experiments conducted with and without microbial processes are commonly used to study the effects of environmental microorganisms on the degradation of organic pollutants. However, the effects of biological pretreatment (sterilization) on organic matter often have a negative impact on such experiments. Based on the principle of water total organic carbon (TOC) analysis, the effects of physical sterilization treatments on determination of TOC and other water quality parameters were investigated. The results revealed that two conventional physical sterilization treatments, autoclaving and 60Co gamma-radiation sterilization, led to the direct decomposition of some organic pollutants, resulting in remarkable errors in the analysis of TOC in water samples. Furthermore, the extent of the errors varied with the intensity and the duration of sterilization treatments. Accordingly, a novel sterilization method for water samples, 0.45 microm micro-filtration coupled with ultraviolet radiation (MCUR), was developed in the present study. The results indicated that the MCUR method was capable of exerting a high bactericidal effect on the water sample while significantly decreasing the negative impact on the analysis of TOC and other water quality parameters. Before and after sterilization treatments, the relative errors of TOC determination could be controlled to lower than 3% for water samples with different categories and concentrations of organic pollutants by using MCUR.

  12. Recent development in the application of alternative sterilization technologies to prepared dishes: A review.

    PubMed

    Huang, Mengsha; Zhang, Min; Bhandari, Bhesh

    2018-01-23

    Sterilization is one of the most effective food preservation methods. Conventional thermal sterilization commonly used in food industry usually causes the deterioration of food quality. Flavor, aroma, and texture, among other attributes, are significantly affected by thermal sterilization. However, demands of consumers for nutritious and safe dishes with a minimum change in their original textural and sensory properties are growing rapidly. In order to meet these demands, new approaches have been explored in the last few years to extend the shelf-life of dishes. This review discusses advantages and disadvantages of currently available physical sterilization technologies, including irradiation (eg. Gamma rays, X-rays, e-beams), microwave and radio frequency when used in prepared dishes. The preservation effect of these technologies on prepared dishes are normally evaluated by microbiological and sensory analyses.

  13. Gamma inert sterilization: a solution to polyethylene oxidation?

    PubMed

    Medel, Francisco J; Kurtz, Steven M; Hozack, William J; Parvizi, Javad; Purtill, James J; Sharkey, Peter F; MacDonald, Daniel; Kraay, Matthew J; Goldberg, Victor; Rimnac, Clare M

    2009-04-01

    In the 1990s, oxidation was found to occur in ultra-high molecular weight polyethylene total joint replacement components following gamma irradiation and prolonged shelf aging in air. Orthopaedic manufacturers developed barrier packaging to reduce oxidation during and after radiation sterilization. The present study explores the hypothesis that polyethylene components sterilized in a low-oxygen environment undergo similar in vivo oxidative mechanisms as inserts sterilized in air. In addition, the potential influence of the different sterilization processes on the wear performance of the polyethylene components was examined. An analysis of oxidation, wear, and surface damage was performed for forty-eight acetabular liners and 123 tibial inserts. The mean implantation time was 12.3+/-3.7 years for thirty-one acetabular liners that had been gamma sterilized in air and 4.0+/-2.5 years for the seventeen acetabular liners that had been gamma sterilized in inert gas. The mean implantation time was 11.0+/-3.2 years for the twenty-six tibial inserts that had been sterilized in air and 2.8+/-2.2 years for the ninety-seven tibial inserts that had been gamma sterilized in inert gas. Oxidation and hydroperoxide levels were characterized in loaded and unloaded regions of the inserts. Measurable oxidation and oxidation potential were observed in all cohorts. The oxidation and hydroperoxide levels were regional. Surfaces with access to body fluids were more heavily oxidized than protected bearing surfaces were. This variation appeared to be greater in historical (gamma-in-air-sterilized) components. Regarding wear performance, historical and conventional acetabular liners showed similar wear penetration rates, whereas a low incidence of delamination was confirmed for the conventional tibial inserts in the first decade of implantation. The present study explores the impact of industry-wide changes in sterilization practices for polyethylene. We found lower oxidation and oxidation potential in the conventional acetabular liners and tibial inserts that had been gamma sterilized in inert gas as compared with the historical components that had been gamma sterilized in air. However, we also found strong evidence that conventional components undergo mechanisms of in vivo oxidation similar to those observed following gamma irradiation in air. In addition, gamma sterilization in inert gas did not provide polyethylene with a significant improvement in terms of wear resistance as compared with gamma sterilization in air, except for a lower incidence of delamination in the first decade of implantation for tibial inserts.

  14. Quality comparison of continuous steam sterilization segmented-flow aseptic processing versus conventional canning of whole and sliced mushrooms.

    PubMed

    Anderson, N M; Walker, P N

    2011-08-01

    This study was carried out to investigate segmented-flow aseptic processing of particle foods. A pilot-scale continuous steam sterilization unit capable of producing shelf stable aseptically processed whole and sliced mushrooms was developed. The system utilized pressurized steam as the heating medium to achieve high temperature-short time processing conditions with high and uniform heat transfer that will enable static temperature penetration studies for process development. Segmented-flow technology produced a narrower residence time distribution than pipe-flow aseptic processing; thus, whole and sliced mushrooms were processed only as long as needed to achieve the target F₀  = 7.0 min and were not overcooked. Continuous steam sterilization segmented-flow aseptic processing produced shelf stable aseptically processed mushrooms of superior quality to conventionally canned mushrooms. When compared to conventionally canned mushrooms, aseptically processed yield (weight basis) increased 6.1% (SD = 2.9%) and 6.6% (SD = 2.2%), whiteness (L) improved 3.1% (SD = 1.9%) and 4.7% (SD = 0.7%), color difference (ΔE) improved 6.0% (SD = 1.3%) and 8.5% (SD = 1.5%), and texture improved 3.9% (SD = 1.7%) and 4.6% (SD = 4.2%), for whole and sliced mushrooms, respectively. Segmented-flow aseptic processing eliminated a separate blanching step, eliminated the unnecessary packaging of water and promoted the use of bag-in-box and other versatile aseptic packaging methods. Segmented-flow aseptic processing is capable of producing shelf stable aseptically processed particle foods of superior quality to a conventionally canned product. This unique continuous steam sterilization process eliminates the need for a separate blanching step, reduces or eliminates the need for a liquid carrier, and promotes the use of bag-in-box and other versatile aseptic packaging methods. © 2011 Institute of Food Technologists®

  15. Improved Sterilization of Sensitive Biomaterials with Supercritical Carbon Dioxide at Low Temperature

    PubMed Central

    Bernhardt, Anne; Wehrl, Markus; Paul, Birgit; Hochmuth, Thomas; Schumacher, Matthias; Schütz, Kathleen; Gelinsky, Michael

    2015-01-01

    The development of bio-resorbable implant materials is rapidly going on. Sterilization of those materials is inevitable to assure the hygienic requirements for critical medical devices according to the medical device directive (MDD, 93/42/EG). Biopolymer-containing biomaterials are often highly sensitive towards classical sterilization procedures like steam, ethylene oxide treatment or gamma irradiation. Supercritical CO2 (scCO2) treatment is a promising strategy for the terminal sterilization of sensitive biomaterials at low temperature. In combination with low amounts of additives scCO2 treatment effectively inactivates microorganisms including bacterial spores. We established a scCO2 sterilization procedure under addition of 0.25% water, 0.15% hydrogen peroxide and 0.5% acetic anhydride. The procedure was successfully tested for the inactivation of a wide panel of microorganisms including endospores of different bacterial species, vegetative cells of gram positive and negative bacteria including mycobacteria, fungi including yeast, and bacteriophages. For robust testing of the sterilization effect with regard to later application of implant materials sterilization all microorganisms were embedded in alginate/agarose cylinders that were used as Process Challenge Devices (PCD). These PCD served as surrogate models for bioresorbable 3D scaffolds. Furthermore, the impact of scCO2 sterilization on mechanical properties of polysaccharide-based hydrogels and collagen-based scaffolds was analyzed. The procedure was shown to be less compromising on mechanical and rheological properties compared to established low-temperature sterilization methods like gamma irradiation and ethylene oxide exposure as well as conventional steam sterilization. Cytocompatibility of alginate gels and scaffolds from mineralized collagen was compared after sterilization with ethylene oxide, gamma irradiation, steam sterilization and scCO2 treatment. Human mesenchymal stem cell viability and proliferation were not compromised by scCO2 treatment of these materials and scaffolds. We conclude that scCO2 sterilization under addition of water, hydrogen peroxide and acetic anhydride is a very effective, gentle, non-cytotoxic and thus a promising alternative sterilization method especially for biomaterials. PMID:26067982

  16. Investigating the Detrimental Effects of Low Pressure Plasma Sterilization on the Survival of Bacillus subtilis Spores Using Live Cell Microscopy.

    PubMed

    Fuchs, Felix M; Raguse, Marina; Fiebrandt, Marcel; Madela, Kazimierz; Awakowicz, Peter; Laue, Michael; Stapelmann, Katharina; Moeller, Ralf

    2017-11-30

    Plasma sterilization is a promising alternative to conventional sterilization methods for industrial, clinical, and spaceflight purposes. Low pressure plasma (LPP) discharges contain a broad spectrum of active species, which lead to rapid microbial inactivation. To study the efficiency and mechanisms of sterilization by LPP, we use spores of the test organism Bacillus subtilis because of their extraordinary resistance against conventional sterilization procedures. We describe the production of B. subtilis spore monolayers, the sterilization process by low pressure plasma in a double inductively coupled plasma reactor, the characterization of spore morphology using scanning electron microscopy (SEM), and the analysis of germination and outgrowth of spores by live cell microscopy. A major target of plasma species is genomic material (DNA) and repair of plasma-induced DNA lesions upon spore revival is crucial for survival of the organism. Here, we study the germination capacity of spores and the role of DNA repair during spore germination and outgrowth after treatment with LPP by tracking fluorescently-labelled DNA repair proteins (RecA) with time-resolved confocal fluorescence microscopy. Treated and untreated spore monolayers are activated for germination and visualized with an inverted confocal live cell microscope over time to follow the reaction of individual spores. Our observations reveal that the fraction of germinating and outgrowing spores is dependent on the duration of LPP-treatment reaching a minimum after 120 s. RecA-YFP (yellow fluorescence protein) fluorescence was detected only in few spores and developed in all outgrowing cells with a slight elevation in LPP-treated spores. Moreover, some of the vegetative bacteria derived from LPP-treated spores showed an increase in cytoplasm and tended to lyse. The described methods for analysis of individual spores could be exemplary for the study of other aspects of spore germination and outgrowth.

  17. Evaluation of high-temperature and short-time sterilization of injection ampules by microwave heating.

    PubMed

    Sasaki, K; Honda, W; Miyake, Y

    1998-01-01

    The high-temperature and short-time sterilization by microwave heating with a continuous microwave sterilizer (MWS) was evaluated. The evaluation were performed with respect to: [1] lethal effect against microorganisms corresponding to F-value, and [2] reliability of MWS sterilization process. Bacillus stearothermophilus ATCC 7953 spores were used as the biological indicator and the heat-resistance of spores was evaluated with conventional heating method (121-129 degrees C). In MWS sterilization (125-135 degrees C), the actual lethal effect against B. stearothermophilus spores was almost in agreement with the F-value and the survival curve against the F-value was quite consistent with that for the autoclave. These results suggest that the actual lethal effect could be estimated by the F-value with heat-resistance parameters of spores from lower than actual temperatures and that there was no nonthermal effect of the microwave on B. stearothermophilus spores. The reliability of sterilization with the MWS was confirmed using more than 25,000 test ampules containing biological indicators. All biological indicators were killed, thus the present study shows that the MWS was completely reliable for all ampules.

  18. About the Sterilization of Chitosan Hydrogel Nanoparticles

    PubMed Central

    Galante, Raquel; Rediguieri, Carolina F.; Kikuchi, Irene Satiko; Vasquez, Pablo A. S.; Colaço, Rogério; Pinto, Terezinha J. A.

    2016-01-01

    In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP) associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility) with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS) hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation), a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP) hydrogel nanoparticles (CS-HNP), with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol). Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles. PMID:28002493

  19. Peracetic Acid: A Practical Agent for Sterilizing Heat-Labile Polymeric Tissue-Engineering Scaffolds

    PubMed Central

    Yoganarasimha, Suyog; Trahan, William R.; Best, Al M.; Bowlin, Gary L.; Kitten, Todd O.; Moon, Peter C.

    2014-01-01

    Advanced biomaterials and sophisticated processing technologies aim at fabricating tissue-engineering scaffolds that can predictably interact within a biological environment at the cellular level. Sterilization of such scaffolds is at the core of patient safety and is an important regulatory issue that needs to be addressed before clinical translation. In addition, it is crucial that meticulously engineered micro- and nano- structures are preserved after sterilization. Conventional sterilization methods involving heat, steam, and radiation are not compatible with engineered polymeric systems because of scaffold degradation and loss of architecture. Using electrospun scaffolds made from polycaprolactone, a low melting polymer, and employing spores of Bacillus atrophaeus as biological indicators, we compared ethylene oxide, autoclaving and 80% ethanol to a known chemical sterilant, peracetic acid (PAA), for their ability to sterilize as well as their effects on scaffold properties. PAA diluted in 20% ethanol to 1000 ppm or above sterilized electrospun scaffolds in 15 min at room temperature while maintaining nano-architecture and mechanical properties. Scaffolds treated with PAA at 5000 ppm were rendered hydrophilic, with contact angles reduced to 0°. Therefore, PAA can provide economical, rapid, and effective sterilization of heat-sensitive polymeric electrospun scaffolds that are used in tissue engineering. PMID:24341350

  20. Affinity adsorption of glucose degradation products improves the biocompatibility of conventional peritoneal dialysis fluid.

    PubMed

    Ishikawa, Naoyoshi; Miyata, Toshio; Ueda, Yasuhiko; Inagi, Reiko; Izuhara, Yuko; Yuzawa, Hiroko; Onogi, Hiroshi; Nishina, Makoto; Nangaku, Masaomi; Van Ypersele De Strihou, Charles; Kurokawa, Kiyoshi

    2003-01-01

    Reactive carbonyl compounds (RCOs) present in peritoneal dialysis (PD) fluid have been incriminated in the progressive deterioration of the peritoneal membrane in long-term PD patients. They are initially present in fresh conventional heat-sterilized glucose PD fluid and are supplemented during dwell time by the diffusion of blood RCOs within the peritoneal cavity. In the present study, RCO entrapping agents were immobilized on affinity beads to adsorb RCOs both in fresh PD fluid and in PD effluent. The RCO trapping potential of various compounds was assessed in vitro first by dissolving them in the tested fluid and subsequently after coupling with either epoxy- or amino-beads. The tested fluids include fresh heat-sterilized glucose and non-glucose PD fluids, and PD effluent. Their RCOs contents, that is, glyoxal (GO), methylglyoxal (MGO), 3-deoxyglucosone (3-DG), formaldehyde, 5-hydroxymethylfuraldehyde, acetaldehyde, and 2-furaldehyde were monitored by reverse-phase high-pressure liquid chromatography. The biocompatibility of PD fluid was assessed by a cytotoxic assay with either human epidermoid cell line A431 cells or with primary cultured human peritoneal mesothelial cells. Among the tested RCO entrapping agents, hydrazine coupled to epoxy-beads proved the most efficient. It lowered the concentrations of three dicarbonyl compounds (GO, MGO, and 3-DG) and those of aldehydes present in fresh heat-sterilized glucose PD fluid toward the low levels observed in filter-sterilized glucose PD fluid. It did not change the glucose and electrolytes concentration of the PD fluid but raised its pH from 5.2 to 5.9. Hydrazine-coupled epoxy-bead also lowered the PD effluent content of total RCOs, measured by the 2,4-dinitrophenylhydrazone (DNPH) method. The cytotoxicity of heat-sterilized PD fluid incubated with hydrazine-coupled epoxy-beads was decreased to the level observed in filter-sterilized PD fluid as the result of the raised pH and the lowered RCOs levels. Hydrazine-coupled epoxy-beads reduce the levels of a variety of dicarbonyls and aldehydes present in heat-sterilized glucose PD fluid to those in filter-sterilized PD fluid, without altering glucose, lactate, and electrolytes contents but with a rise in pH. Incubated with PD effluents, it is equally effective in reducing the levels of serum-derived RCOs. RCO entrapping agents immobilized on affinity beads improve in vitro the biocompatibility of conventional heat-sterilized glucose PD fluid. Their clinical applicability requires further studies.

  1. Shelf-stable egg-based products processed by high pressure thermal sterilization

    USDA-ARS?s Scientific Manuscript database

    Producing a thermally sterilized egg-based product with increased shelf life without losing the sensory and nutritional properties of the freshly prepared product is challenging. Until recently, all commercial shelf-stable egg-based products were sterilized using conventional thermal processing; how...

  2. Family Planning Practices, Programmes and Policies in India Including Implants and Injectables with a Special Focus on Jharkhand, India: A Brief Review

    PubMed Central

    Dehury, Ranjit Kumar

    2015-01-01

    The National Family Health Survey (NFHS)-3 clearly delineates that the usage of contraceptive practices has increased considerably but is more inclined toward terminal methods of contraception especially the female sterilization. The fact is also evident from various studies carried out from time to time in different Indian states. Given the context we carried out a short review to understand the family planning practices, programs and policies in India including implants and injectable contraceptives with a special focus on the state of Jharkhand. We found that among the reversible methods IUCD (intra uterine contraceptive devices), OC (oral contraceptive) pills and condoms are the most commonly used methods. In this review, in addition to national picture, we specially focused on the state of Jharkhand owing to its very gloomy picture of family planning practices as per NFHS -3 reports. The current usage of any methods of contraception in Jharkhand is only 35.7% out of which terminal methods especially female sterilization accounts to 23.4% and male sterilization being only 0.4%. Similar picture is also reflected in the conventional methods such as; IUCD-0.6%, oral pill -3.8% and condom-2.7%. Compared to the national figure the unmet need for family planning in Jharkhand is also relatively high for the conventional reversible methods than that of terminal methods which is 11.9 and 11.3 respectively. Injectable contraceptives are available only through private or social marketing channels, because of which their use is limited. The studies carried out in different Indian states show improvement in contraceptive prevalence but the same needs further improvement. PMID:26674943

  3. Family Planning Practices, Programmes and Policies in India Including Implants and Injectables with a Special Focus on Jharkhand, India: A Brief Review.

    PubMed

    Samal, Janmejaya; Dehury, Ranjit Kumar

    2015-11-01

    The National Family Health Survey (NFHS)-3 clearly delineates that the usage of contraceptive practices has increased considerably but is more inclined toward terminal methods of contraception especially the female sterilization. The fact is also evident from various studies carried out from time to time in different Indian states. Given the context we carried out a short review to understand the family planning practices, programs and policies in India including implants and injectable contraceptives with a special focus on the state of Jharkhand. We found that among the reversible methods IUCD (intra uterine contraceptive devices), OC (oral contraceptive) pills and condoms are the most commonly used methods. In this review, in addition to national picture, we specially focused on the state of Jharkhand owing to its very gloomy picture of family planning practices as per NFHS -3 reports. The current usage of any methods of contraception in Jharkhand is only 35.7% out of which terminal methods especially female sterilization accounts to 23.4% and male sterilization being only 0.4%. Similar picture is also reflected in the conventional methods such as; IUCD-0.6%, oral pill -3.8% and condom-2.7%. Compared to the national figure the unmet need for family planning in Jharkhand is also relatively high for the conventional reversible methods than that of terminal methods which is 11.9 and 11.3 respectively. Injectable contraceptives are available only through private or social marketing channels, because of which their use is limited. The studies carried out in different Indian states show improvement in contraceptive prevalence but the same needs further improvement.

  4. Retransformation of a male sterile barnase line with the barstar gene as an efficient alternative method to identify male sterile-restorer combinations for heterosis breeding.

    PubMed

    Bisht, Naveen C; Jagannath, Arun; Burma, Pradeep K; Pradhan, Akshay K; Pental, Deepak

    2007-06-01

    We report in this study, an improved method for identifying male sterile-restorer combinations using the barnase-barstar system of pollination control for heterosis breeding in crop plants, as an alternative to the conventional line x tester cross method. In this strategy, a transgenic male sterile barnase line was retransformed with appropriate barstar constructs. Double transformants carrying both the barnase and barstar genes were identified and screened for their male fertility status. Using this strategy, 66-90% of fertile retransformants (restored events) were obtained in Brassica juncea using two different barstar constructs. Restored events were analysed for their pollen viability and copy number of the barstar gene. Around 90% of the restored events showed high pollen viability and approximately 30% contained single copy integrations of the barstar gene. These observations were significantly different from those made in our earlier studies using line (barnase) x tester (barstar) crosses, wherein only two viable male sterile-restorer combinations were identified by screening 88 different cross-combinations. The retransformation strategy not only generated several independent restorers for a given male sterile line from a single transformation experiment but also identified potential restorers in the T(0) generation itself leading to significant savings in time, cost and labour. Single copy restored plants with high pollen viability were selfed to segregate male sterile (barnase) and restorer (barstar) lines in the T(1) progeny which could subsequently be diversified into appropriate combiners for heterosis breeding. This strategy will be particularly useful for crop plants where poor transformation frequencies and/or lengthy transformation protocols are a major limitation.

  5. Application effect of sterile normal saline ice for post-partum hemorrhage at the time of cesarean delivery: A retrospective review.

    PubMed

    Cheng, Wenjing; Wang, Qiushi; Zhang, Zhenyu

    2016-10-01

    Post-partum hemorrhage (PPH) is a common complication of cesarean sections (CS) and affects maternal and newborn health. We used a new method to control bleeding and compared its efficacy with conventional methods. Eighty-six women who experienced PPH with volume of bleeding over 1000 mL in CS between January 2008 and January 2012 were chosen as samples. Thirty-three underwent the new method in which normal saline ice blocks are placed in the uterus, and 53 underwent the conventional method. We evaluated blood loss, volume of transfusion and complications. Patients who were treated with ice blocks had better hemostatic efficacy than those who underwent the conventional method (1450 ± 251.9 mL vs 1800 ± 278.9 mL; P < 0.001); they also had less blood transfusion (806.1 ± 242.3 mL vs 1222.6 ± 308.0 mL; P < 0.001), lower rate of hysterectomy and infection (3.03% vs 5.66%; P = 0.971; 0% vs 7.55%; P = 0.276), and shorter duration of hospital stay (5.3 ± 0.5 days vs 7.6 ± 3.0 days; P < 0.001). PPH in CS can be treated with peeled sterile normal saline ice blocks, a simple and reliable method for stopping bleeding. Nonetheless, there needs to be a large randomized control trial for confirmation. © 2016 Japan Society of Obstetrics and Gynecology.

  6. Gnotobiotic pigs-derivation and rearing.

    PubMed

    Miniats, O P; Jol, D

    1978-10-01

    The procurement, rearing, nutrition and microbiological monitoring of gnotobiotic pigs and a method for conditioning of primary, colostrum-deprived, specific pathogen free pigs is described. As compared to the established hysterectomy and closed hysterotomy methods for the derivation of gnotobiotic piglets an alternative approach, open caesarian section with the sow maintained under general halothane-nitrous oxide anaesthesia and the introduction of each fetus into the sterile isolator via a liquid germicidal trap, was found to be more efficient and equally successful in providing viable and microbiologically sterile piglets. Two sterile commercially available milk diets, a special formula for orphan animals and condensed cow's milk, when the latter was supplemented with injectable vitamin E, selenium and iron, proved adequate for satisfactory health of the animals. Two types of pelleted starter rations, sterilized by 4.5 megarads of gamma irradiation, provided adequately for the nutritional needs of older gnotobiotic pigs. Results of microbiological monitoring indicated that the surgical and rearing methods employed were capable of preventing contamination of the animals with bacteria, mycoplasma, yeasts, molds, protozoa and helminths but probably could not exclude occasional vertically transmitted viral infections. Exposure of the animals for four weeks to selected strains of lactobacilli, fecal streptococci and Escherichia coli did not result in visible disease while they were maintained in isolators and conditioned them for transfer into a conventional microbial environment.

  7. A novel herbicide-inducible male sterility system.

    PubMed

    Zhang, Jinhui; Zhang, Wenlu; Yen, Yang; Long, Hai; Deng, Guangbing; Pan, Zhifen; Yu, Maoqun

    2010-11-01

    Heterosis is a phenomenon that first-generation offspring perform better than their parents. Conventional breeding methods have their shortcomings. It would be optimal to construct inducible male sterile plants. We developed a novel system for creating male sterile transgenic plants by downregulating the specific expression of the glyphosate tolerance CP4 EPSPS gene in male reproductive tissues. Transcriptional repression was achieved by manipulating DNA binding proteins with their specific corresponding sites. We transferred the CP4 EPSPS gene driven by a modified CaMV 35S promoter with three tetracycline operator copies in the vicinity of the TATA box and tetracycline repressor gene under the control of an anther-specific promoter Osg6B to Arabidopsis thaliana. As a result, we successfully obtained controllable transgenic plants: the whole plant could tolerate exposure of glyphosate but the male tissue was sensitive. The novel inducible male sterility system is applied and easy to handle, so it might be applicable to a wide range of crop plants. 2010 Society of Chemical Industry

  8. Antibacterial activities of amorphous cefuroxime axetil ultrafine particles prepared by high gravity antisolvent precipitation (HGAP).

    PubMed

    Zhao, Hong; Kang, Xu-liang; Chen, Xuan-li; Wang, Jie-xin; Le, Yuan; Shen, Zhi-gang; Chen, Jian-feng

    2009-01-01

    In vitro and in vivo antibacterial activities on the Staphylococcus aureus and Escherichia coli of the amorphous cefuroxime axetil (CFA) ultrafine particles prepared by HGAP method were investigated in this paper. The conventional sprayed CFA particles were studied as the control group. XRD, SEM, BET tests were performed to investigate the morphology changes of the samples before and after sterile. The in vitro dissolution test, minimal inhibitory concentrations (MIC) and the in vivo experiment on mice were explored. The results demonstrated that: (i) The structure, morphology and amorphous form of the particles could be affected during steam sterile process; (ii) CFA particles with different morphologies showed varied antibacterial activities; and (iii) the in vitro and in vivo antibacterial activities of the ultrafine particles prepared by HGAP is markedly stronger than that of the conventional sprayed amorphous particles.

  9. Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test.

    PubMed

    Freitas, Raphael Ribeiro de Aquino; Tardelli, Maria Angela

    2016-05-24

    To compare sterility and microbial (bacteria and fungi) load in the outer part of hyperbaric bupivacaine (Neocaína®) in ampoule and bupivacaine in vial, in conventional and sterile pack formulations. The sterile packs were divided into two groups: G1 (n=16) with ampoules and G2 (n=16) with vials. Conventional formulations were divided into two groups, being G3 (n=16) with ampoules and G4 (n=16) with vials. The ampoules and vials were opened and had their content drawn. The empty bottles were then placed in sterile plastic bags and sent for analysis of microbial load (bacteria and fungi) and sterility testing. Data were analyzed using the χ2 test with Yates correction, and 95% confidence interval. G1 and G2 showed no bacterial growth when compared to conventional groups (p<0.001). The most common agent in conventional microbiological samples was Staphylococcus aureus. There was no fungal growth in both groups. The use of (sterile pack) reduces the microbial load of bottles, and would decrease the chance of exposure to potential contamination of the anesthetic solution. Comparar a esterilidade e a carga microbiana (bactérias e fungos) da parte externa dos frascos de envasamento de bupivacaína hiperbárica (Neocaína®) em ampola e bupivacaína em frasco-ampola das apresentações convencional e estéril (sterile pack). As apresentações estéreis (sterile pack) foram distribuídas em dois grupos, sendo que o G1 (n=16) continha as ampolas e o G2 (n=16), os frascos-ampola. As apresentações convencionais foram distribuídas em dois grupos, a saber G3 (n=16) com as ampolas e G4 (n=16) com os frascos-ampola. As ampolas e os frascos-ampolas eram abertos e tinham seu conteúdo aspirado. Os frascos vazios eram, então, acondicionados em sacos plásticos estéreis e enviados para análise quanto à carga microbiana (bactérias e fungos), bem como para o teste de esterilidade. Os dados foram analisados por meio do teste χ2 com correção Yates com intervalo de confiança de 95%. Os grupos G1 e G2 não apresentaram crescimento bacteriano quando comparado aos grupos convencionais (p<0,001). O microbiano mais comum nas amostras convencionais foi o Staphylococcus aureus. Não houve crescimento de fungos em nenhum dos grupos. O uso de embalagens estéreis (sterile pack) diminui a carga microbiana dos frascos de envasamentos, o que diminuiria a chance de exposição a uma potencial contaminação da solução anestésica.

  10. Culture dependent and independent analysis of bacterial communities associated with commercial salad leaf vegetables.

    PubMed

    Jackson, Colin R; Randolph, Kevin C; Osborn, Shelly L; Tyler, Heather L

    2013-12-01

    Plants harbor a diverse bacterial community, both as epiphytes on the plant surface and as endophytes within plant tissue. While some plant-associated bacteria act as plant pathogens or promote plant growth, others may be human pathogens. The aim of the current study was to determine the bacterial community composition of organic and conventionally grown leafy salad vegetables at the point of consumption using both culture-dependent and culture-independent methods. Total culturable bacteria on salad vegetables ranged from 8.0 × 10(3) to 5.5 × 10(8) CFU g(-1). The number of culturable endophytic bacteria from surface sterilized plants was significantly lower, ranging from 2.2 × 10(3) to 5.8 × 10(5) CFU g(-1). Cultured isolates belonged to six major bacterial phyla, and included representatives of Pseudomonas, Pantoea, Chryseobacterium, and Flavobacterium. Eleven different phyla and subphyla were identified by culture-independent pyrosequencing, with Gammaproteobacteria, Betaproteobacteria, and Bacteroidetes being the most dominant lineages. Other bacterial lineages identified (e.g. Firmicutes, Alphaproteobacteria, Acidobacteria, and Actinobacteria) typically represented less than 1% of sequences obtained. At the genus level, sequences classified as Pseudomonas were identified in all samples and this was often the most prevalent genus. Ralstonia sequences made up a greater portion of the community in surface sterilized than non-surface sterilized samples, indicating that it was largely endophytic, while Acinetobacter sequences appeared to be primarily associated with the leaf surface. Analysis of molecular variance indicated there were no significant differences in bacterial community composition between organic versus conventionally grown, or surface-sterilized versus non-sterilized leaf vegetables. While culture-independent pyrosequencing identified significantly more bacterial taxa, the dominant taxa from pyrosequence data were also detected by traditional culture-dependent methods. The use of pyrosequencing allowed for the identification of low abundance bacteria in leaf salad vegetables not detected by culture-dependent methods. The presence of a range of bacterial populations as endophytes presents an interesting phenomenon as these microorganisms cannot be removed by washing and are thus ingested during salad consumption.

  11. Culture dependent and independent analysis of bacterial communities associated with commercial salad leaf vegetables

    PubMed Central

    2013-01-01

    Background Plants harbor a diverse bacterial community, both as epiphytes on the plant surface and as endophytes within plant tissue. While some plant-associated bacteria act as plant pathogens or promote plant growth, others may be human pathogens. The aim of the current study was to determine the bacterial community composition of organic and conventionally grown leafy salad vegetables at the point of consumption using both culture-dependent and culture-independent methods. Results Total culturable bacteria on salad vegetables ranged from 8.0 × 103 to 5.5 × 108 CFU g-1. The number of culturable endophytic bacteria from surface sterilized plants was significantly lower, ranging from 2.2 × 103 to 5.8 × 105 CFU g-1. Cultured isolates belonged to six major bacterial phyla, and included representatives of Pseudomonas, Pantoea, Chryseobacterium, and Flavobacterium. Eleven different phyla and subphyla were identified by culture-independent pyrosequencing, with Gammaproteobacteria, Betaproteobacteria, and Bacteroidetes being the most dominant lineages. Other bacterial lineages identified (e.g. Firmicutes, Alphaproteobacteria, Acidobacteria, and Actinobacteria) typically represented less than 1% of sequences obtained. At the genus level, sequences classified as Pseudomonas were identified in all samples and this was often the most prevalent genus. Ralstonia sequences made up a greater portion of the community in surface sterilized than non-surface sterilized samples, indicating that it was largely endophytic, while Acinetobacter sequences appeared to be primarily associated with the leaf surface. Analysis of molecular variance indicated there were no significant differences in bacterial community composition between organic versus conventionally grown, or surface-sterilized versus non-sterilized leaf vegetables. While culture-independent pyrosequencing identified significantly more bacterial taxa, the dominant taxa from pyrosequence data were also detected by traditional culture-dependent methods. Conclusions The use of pyrosequencing allowed for the identification of low abundance bacteria in leaf salad vegetables not detected by culture-dependent methods. The presence of a range of bacterial populations as endophytes presents an interesting phenomenon as these microorganisms cannot be removed by washing and are thus ingested during salad consumption. PMID:24289725

  12. Histological changes induced by 15 F CO2 laser microprobe especially designed for root canal sterilization: an in-vivo study

    NASA Astrophysics Data System (ADS)

    Kesler, Gavriel; Koren, Rumelia; Gal, Rivka

    1998-04-01

    Until now, no suitable delivery fiber existed for CO2 laser endodontic radiation in the apical region where it is most difficult to eliminate the pulp tissue using conventional methods. To overcome this problem, we designed a microprobe that reaches closer to the apex, distributing the energy density to a smaller area of the root canal, thus favorably increasing the thermal effects. The 15 F CO2 microprobe is a flexible, hollow, metal fiber, 300 micrometer in diameter and 20 mm in length, coupled onto a handpiece, with the following radiation parameters: wavelength -- 10.6 micrometer; pulse duration -- 50m/sec; energy per pulse 0.25 joule; energy density -- 353.7J/cm2 per pulse; power on tissue -- 5 W. The study was conducted on 30 vital maxillary or mandibulary; central, lateral, or premolar teeth destined for extraction due to periodontal problems. Twenty were experimentally treated with pulsed CO2 laser delivered by this newly developed fiber after conventional root canal preparation. Temperature measured at three points on the root surface during laser treatment did not exceed 38 degrees Celsius. Ten teeth represented the control group in which only root canal preparation was performed in the conventional method. Histological examination of the laser treated teeth showed coagulation necrosis and vacuolization of remaining pulp tissue in the root canal periphery. Primary and secondary dentin appeared normal, in all cases treated with 15 F CO2 laser. Gramm stain and bacteriologic examination revealed complete sterilization. These results demonstrate the unique capabilities of this special microprobe in sterilization of the root canal, and no thermal damage to the surrounding tissue.

  13. Histological changes induced by CO2 laser microprobe specially designed for root canal sterilization: in vivo study.

    PubMed

    Kesler, G; Koren, R; Kesler, A; Hay, N; Gal, R

    1998-10-01

    Until now, no suitable delivery fiber has existed for CO2 laser endodontic radiation in the apical region, where it is most difficult to eliminate the pulp tissue using conventional methods. To overcome this problem, we have designed a microprobe that reaches closer to the apex, distributing the energy density to a smaller area of the root canal and thus favorably increasing the thermal effects. A CO2 laser microprobe coupled onto a special hand piece was attached to the delivery fiber of a Sharplan 15-F CO2 laser. The study was conducted on 30 vital maxillary or mandibulary, central, lateral, or premolar teeth destined for extraction due to periodontal problems. Twenty were experimentally treated with pulsed CO2 laser delivered by this newly developed fiber after conventional root canal preparation. Temperature measured at three points on the root surface during laser treatment did not exceed 38 degrees C. Ten teeth represented the control group, in which only root canal preparation was performed in the conventional method. Histological examination of the laser-treated teeth showed coagulation necrosis and vacuolization of the remaining pulp tissue in the root canal periphery. Primary and secondary dentin appeared normal in all cases treated with 15-F CO2 laser. Gram stain and bacteriologic examination revealed complete sterilization. These results demonstrate the unique capabilities of this special microprobe in sterilization of the root canal, with no thermal damage to the surrounding tissue. The combination of classical root canal preparation with CO2 laser irradiation using this special microprobe before closing the canal can drastically change the quality of root canal fillings.

  14. Development of a novel controllable, multidirectional, reusable metallic port with a wide working space.

    PubMed

    Hosaka, Seiji; Ohdaira, Takeshi; Umemoto, Satoshi; Hashizume, Makoto; Kawamoto, Shunji

    2013-12-01

    Endoscopic surgery is currently a standard procedure in many countries. Furthermore, conventional four-port laparoscopic cholecystectomy is developing into a single-port procedure. However, in many developing countries, disposable medical products are expensive and adequate medical waste disposable facilities are absent. Advanced medical treatments such as laparoscopic or single-port surgeries are not readily available in many areas of developing countries, and there are often no other sterilization methods besides autoclaving. Moreover, existing reusable metallic ports are impractical and are thus not widely used. We developed a novel controllable, multidirectional single-port device that can be autoclaved, and with a wide working space, which was employed in five patients. In all patients, laparoscopic cholecystectomy was accomplished without complications. Our device facilitates single-port surgery in areas of the world with limited sterilization methods and offers a novel alternative to conventional tools for creating a smaller incision, decrease postoperative pain, and improve cosmesis. This novel device can also lower the cost of medical treatment and offers a promising tool for major surgeries requiring a wide working space.

  15. Solar Disinfection of MODS Mycobacterial Cultures in Resource-Poor Settings

    PubMed Central

    Nathavitharana, Ruvandhi; Coronel, Jorge; Moore, David A. J.

    2007-01-01

    Introduction Safe disposal of TB culture material in which the infectious burden of clinical samples has been greatly amplified is an important challenge in resource-limited settings. The bactericidal capacity of solar cookers has been demonstrated previously for conventional bacteria and contaminated clinical waste. We investigated the use of a simple solar cooker for the sterilization of mycobacterial broth cultures from the microscopic observation drug susceptibility assay (MODS). Methods Simulated TB culture materials were prepared by inoculating 24-well MODS plates with 500 µL of a known concentration of Mycobacterium bovis BCG. In a series of experiments, samples were simultaneously placed inside a box-type solar cooker and control box and removed at timepoints between 15 minutes and 6 hours. Quantitative cultures were performed using retrieved samples to determine sterilization effect. Results All cultures from the control box were positive at or within 1–4 logs of inoculation concentration. Simulated culture plates at concentrations from 103colony-forming-units (CFU)/ml to 107 CFU/ml were completely sterilized after only one hour of cooker exposure, at temperatures between 50–102°C. At 109 CFU/ml (far in excess of diagnostic cultures), it was only possible to recover mycobacterial growth in plates removed after 15 minutes. By 30 minutes all plates were effectively sterilized. Discussion Solar disinfection provides a very effective, safe and low-cost alternative to conventional equipment used for disposal of mycobacterial culture material. Effect of climatic conditions and optimal operating procedure remain to be defined. PMID:17971863

  16. Effects of Processing Conditions During Manufacture on Retronasal-Aroma Compounds from a Milk Coffee Drink.

    PubMed

    Ikeda, Michio; Akiyama, Masayuki; Hirano, Yuta; Miyazi, Kazuhiro; Kono, Masaya; Imayoshi, Yuriko; Iwabuchi, Hisakatsu; Onodera, Takeshi; Toko, Kiyoshi

    2018-03-01

    To develop a ready-to-drink (RTD) milk coffee retaining the original coffee flavor, the effects of processing conditions during manufacture on retronasal-arma (RA) compounds from the milk coffee were investigated by gas chromatography-mass spectrometry using an RA simulator (RAS). Thirteen of 46 detected compounds in the RAS effluent (RAS compounds) decreased significantly following pH adjustment of coffee (from pH 5.1 to 6.8) and 5 compounds increased. RAS compounds from coffee tended to decrease through the pH adjustment and subsequent sterilization. Significantly higher amounts of 13 RAS compounds were released from the milk coffee produced using a blending-after-sterilization (BAS) process without the pH adjustment than from that using a blending-before-sterilization (BBS) process with the pH adjustment. In BAS-processed milk coffee, significantly lower amounts of 8 high-volatility compounds and 1H-pyrrole were released from coffee containing infusion-sterilized (INF) milk than from coffee containing plate-sterilized (PLT) milk, whereas 3 low-volatility compounds were released significantly more from coffee using PLT milk. Principal component analysis revealed that the effect of the manufacturing process (BAS, BBS, or homemade (blending unsterilized coffee without pH adjustment with sterilized milk)) on milk coffee volatiles was larger than that of the sterilization method (INF or PLT) for milk, and that the sterilization method could result in different RAS volatile characteristics in BAS and homemade processes. In conclusion, a BAS process was found to be superior to a BBS process for the manufacture of an RTD milk coffee that retains volatile characteristics similar to that of a homemade milk coffee. Ready-to-drink (RTD) milk coffee manufactured using the conventional blending-before-sterilization process does not retain its original coffee flavor due to pH adjustment of the coffee during the process. The new blending-after-sterilization (BAS) process enabled the production of RTD milk coffee whose volatiles are closer to that of homemade milk coffee, as demonstrated by the results of RAS-GC-MS analysis. The BAS process has already been applied to the manufacture of RTD milk coffees in Japan. © 2018 Institute of Food Technologists®.

  17. Fungal genomes that influence basic physiological processes of black grama and fourwing saltbush in arid southwestern rangelands

    Treesearch

    J.R. Barrow; M. Lucero; P. Osuna-Avila; I. Reyes-Vera; R.E. Aaltonen

    2007-01-01

    Symbiotic fungi confer multiple benefits such as enhanced photosynthetic rates and drought tolerance in host plants. Shrubs and grasses of southwestern deserts are colonized by symbiotic fungi that cannot be removed by conventional sterilization methods. These fungi were extensively studied in Bouteloua eriopoda (Torr.) Torr. and Atriplex...

  18. Effects of sterilization treatments on bulk and surface properties of nanocomposite biomaterials

    PubMed Central

    Ahmed, Maqsood; Punshon, Geoffrey; Darbyshire, Arnold; Seifalian, Alexander M

    2013-01-01

    With the continuous and expanding use of implantable biomaterials in a clinical setting, this study aims to elucidate the influence of sterilization techniques on the material surface and bulk properties of two polyurethane nanocomposite biomaterials. Both solid samples and porous membranes of nondegradable polyhedral oligomeric silsesquioxane poly(carbonate-urea) urethane (POSS-PCU) and a biodegradable poly(caprolactone-urea) urethane (POSS-PCL) were examined. Sterilization techniques included conventional steam sterilization (autoclaving), gamma irradiation, and disinfection via incubating with ethanol (EtOH) for 10 min or 24 h. After treatment, the samples were examined using gel permeation chromatography (GPC), attenuated total reflectance Fourier transform infrared spectroscopy, and tensiometry. Cytotoxicity was evaluated through the culture of endothelial progenitor cells and the efficacy of sterilization method was determined by incubating each sample in tryptone soya broth and fluid thioglycollate medium for cultivation of microorganisms. Although EtOH did not affect the material properties in any form, the samples were found to be nonsterile with microbial growth detected on each of the samples. Gamma irradiation was not only effective in sterilizing both POSS-PCU and POSS-PCL but also led to minor material degradation and displayed a cytotoxic effect on the cultured cells. Autoclaving was found to be the optimal sterilization technique for both solid and porous membranes of the nondegradable POSS-PCU samples as it was successful in sterilizing the samples, displayed no cytotoxic side effects and did not degrade the material. However, the biodegradable POSS-PCL was not able to withstand the harsh environment during autoclaving, resulting in it losing all structural integrity. PMID:24039066

  19. Impact of Cropping Systems, Soil Inoculum, and Plant Species Identity on Soil Bacterial Community Structure.

    PubMed

    Ishaq, Suzanne L; Johnson, Stephen P; Miller, Zach J; Lehnhoff, Erik A; Olivo, Sarah; Yeoman, Carl J; Menalled, Fabian D

    2017-02-01

    Farming practices affect the soil microbial community, which in turn impacts crop growth and crop-weed interactions. This study assessed the modification of soil bacterial community structure by organic or conventional cropping systems, weed species identity [Amaranthus retroflexus L. (redroot pigweed) or Avena fatua L. (wild oat)], and living or sterilized inoculum. Soil from eight paired USDA-certified organic and conventional farms in north-central Montana was used as living or autoclave-sterilized inoculant into steam-pasteurized potting soil, planted with Am. retroflexus or Av. fatua and grown for two consecutive 8-week periods to condition soil nutrients and biota. Subsequently, the V3-V4 regions of the microbial 16S rRNA gene were sequenced by Illumina MiSeq. Treatments clustered significantly, with living or sterilized inoculum being the strongest delineating factor, followed by organic or conventional cropping system, then individual farm. Living inoculum-treated soil had greater species richness and was more diverse than sterile inoculum-treated soil (observed OTUs, Chao, inverse Simpson, Shannon, P < 0.001) and had more discriminant taxa delineating groups (linear discriminant analysis). Living inoculum soil contained more Chloroflexi and Acidobacteria, while the sterile inoculum soil had more Bacteroidetes, Firmicutes, Gemmatimonadetes, and Verrucomicrobia. Organically farmed inoculum-treated soil had greater species richness, more diversity (observed OTUs, Chao, Shannon, P < 0.05), and more discriminant taxa than conventionally farmed inoculum-treated soil. Cyanobacteria were higher in pots growing Am. retroflexus, regardless of inoculum type, for three of the four organic farms. Results highlight the potential of cropping systems and species identity to modify soil bacterial communities, subsequently modifying plant growth and crop-weed competition.

  20. A combination of subcuticular suture and sterile Micropore tape compared with conventional interrupted sutures for skin closure. A controlled trial.

    PubMed Central

    Taube, M.; Porter, R. J.; Lord, P. H.

    1983-01-01

    We have conducted a controlled trial to compare skin closure using conventional interrupted sutures with a combination of subcuticular suture and sterile Micropore tape in 169 patients undergoing appendicectomy, inguinal herniorrhaphy, or saphenofemoral ligation. We have found that the combination technique consistently gives a better cosmetic result and that the tape acts well as a dressing, is convenient, and is well tolerated by patients. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:6344732

  1. Adventures in the Environmental World and Environmental Microbiology Sampling of Air for Pharmaceutical Sterile Compounding.

    PubMed

    Ligugnana, Roberto

    2017-01-01

    Chapter <797> issued by the United States Pharmacopeial Convention, Inc. is the standard for sterile compounding. It is designed to reduce the number of patient infections due to contaminated pharmaceutical preparation. This regulation applies to all staff who prepare compounded sterile preparations and all places where they are produced, including hospitals, clinics, pharmacies, and physician's offices. This article provides the history of environmental microbiology and provides a discussion on environmental microbiology sampling of air for pharmaceutical sterile compounding. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  2. Ecology and thermal inactivation of microbes in and on interplanetary space vehicle components

    NASA Technical Reports Server (NTRS)

    Campbell, J. E.; Reyes, A. L.; Wehby, A. J.; Crawford, R. G.; Wimsatt, J. C.; Peeler, J. T.

    1974-01-01

    Dry heat sterilization of spacecraft was investigated by studying the production of spore crops, and thermal inactivation of the spores, and bacillus subtillus. Spore assays were made by conventional plate count methods, and survival curves for the spores are presented. The results indicate that the inherent resistance of spores from a parent cell can be maintained.

  3. Comparison of the effectiveness of sterilizing endodontic files by 4 different methods: an in vitro study.

    PubMed

    Venkatasubramanian, R; Das, U M; Bhatnagar, S

    2010-01-01

    Sterilization is the best method to counter the threats of microorganisms. The purpose of sterilization in the field of health care is to prevent the spread of infectious diseases. In dentistry, it primarily relates to processing reusable instruments to prevent cross-infection. The aim of this study was to investigate the efficacy of 4 methods of sterilizing endodontic instruments: Autoclaving, carbon dioxide laser sterilization, chemical sterilization (with glutaraldehyde) and glass-bead sterilization. The endodontic file was sterilized by 4 different methods after contaminating it with bacillus stearothermophillus and then checked for sterility by incubating after putting it in test tubes containing thioglycollate medium. The study showed that the files sterilized by autoclave and lasers were completely sterile. Those sterilized by glass bead were 90% sterile and those with glutaraldehyde were 80% sterile. The study concluded that autoclave or laser could be used as a method of sterilization in clinical practice and in advanced clinics; laser can be used also as a chair side method of sterilization.

  4. Complementary and Alternative Approaches to Pain Relief During Labor

    PubMed Central

    Theau-Yonneau, Anne

    2007-01-01

    This review evaluated the effect of complementary and alternative medicine on pain during labor with conventional scientific methods using electronic data bases through 2006 were used. Only randomized controlled trials with outcome measures for labor pain were kept for the conclusions. Many studies did not meet the scientific inclusion criteria. According to the randomized control trials, we conclude that for the decrease of labor pain and/or reduction of the need for conventional analgesic methods: (i) There is an efficacy found for acupressure and sterile water blocks. (ii) Most results favored some efficacy for acupuncture and hydrotherapy. (iii) Studies for other complementary or alternative therapies for labor pain control have not shown their effectiveness. PMID:18227907

  5. NxStage dialysis system-associated thrombocytopenia: a report of two cases.

    PubMed

    Sekkarie, Mohamed; Waldron, Michelle; Reynolds, Texas

    2016-01-01

    Thrombocytopenia in hemodialysis patients has recently been reported to be commonly caused by electron-beam sterilization of dialysis filters. We report the occurrence of thrombocytopenia in the first two patients of a newly established home hemodialysis program. The 2 patients switched from conventional hemodialysis using polysulfone electron-beam sterilized dialyzers to a NxStage system, which uses gamma sterilized polyehersulfone dialyzers incorporated into a drop-in cartridge. The thrombocytopenia resolved after return to conventional dialysis in both patients and recurred upon rechallenge in the patient who opted to retry NxStage. This is the first report of thrombocytopenia with the NxStage system according to the authors’ knowledge. Dialysis-associated thrombocytopenia pathophysiology and clinical significance are not well understood and warrant additional investigations.

  6. Effect of e-beam sterilization on the in vivo performance of conventional UHMWPE tibial plates for total knee arthroplasty.

    PubMed

    Tone, Shine; Hasegawa, Masahiro; Pezzotti, Giuseppe; Puppulin, Leonardo; Sudo, Akihiro

    2017-06-01

    Although the introduction of highly cross-linked polyethylene is effective in reducing the amount of wear, there are still major concerns regarding the use of this material in total knee arthroplasty (TKA), essentially due to the reduction of fatigue resistance and toughness. Monitoring the in vivo performance of different types of UHMWPE is a much needed task to tackle the lack of information on which should be the most reliable choice for TKA. The present study was aimed at investigating the mid-term degradation of electron beam sterilized conventional UHMWPE tibial plates. Visual inspection enabled to grade the surface damage of 12 retrievals according to the Hood's score: the total wear damage correlates to the in vivo time (Spearman's ρ=0.681, p<0.05) and BMI (ρ=0.834, p<0.001). Surface degradation was less severe than that quantified in similar studies on γ-sterilized UHMWPE. Raman and infra-red spectroscopies were utilized to unfold the microstructural modifications. In the load zone, polyethylene whitened damage regions were noticed in the inserts implanted longer than 1year, in which oxidation index (OI) is clearly higher than 1 (max 8). The maximum OI (ρ=0.802, p<0.005) and α c (ρ=0.816, p<0.005) correlate to the implantation time in the load zone. The crystallinity increased along with the extent of oxidation. Concentration of absorbed species from synovial fluid is higher in the contact zone and correlates to maximum OI (Spearman's ρ=0.699, p=0.011). Absorption was promoted in the contact area by the mechanical action of the femoral counterpart and it exacerbated the oxidative degradation in retrievals with high concentration of absorbed species. In the non-load zone, mild but detectable oxidation was observed, probably due to free radicals trapped after sterilization. Although several clinical studies on retrieved tibial bearings have been published so far, monitoring and comparing the in vivo performance of different types of UHMWPE is still a much needed task. The present study reports for the first time results on the effect of sterilization by electron beam on the mid-term in vivo performance of conventional UHMWPE tibial plates. In the present investigation, visual inspection of wear damage based on the Hood's scoring method, Raman micro-spectroscopy and Fourier-transformed infrared spectroscopy were utilized to unveil the damage, the microstructural modifications and the oxidation occurred during implantation. The findings of this investigation have been discussed and compared to previous clinical studies on γ-air sterilized, γ-inert sterilized tibial bearings. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  7. Effects of sterilization treatments on bulk and surface properties of nanocomposite biomaterials.

    PubMed

    Ahmed, Maqsood; Punshon, Geoffrey; Darbyshire, Arnold; Seifalian, Alexander M

    2013-10-01

    With the continuous and expanding use of implantable biomaterials in a clinical setting, this study aims to elucidate the influence of sterilization techniques on the material surface and bulk properties of two polyurethane nanocomposite biomaterials. Both solid samples and porous membranes of nondegradable polyhedral oligomeric silsesquioxane poly(carbonate-urea) urethane (POSS-PCU) and a biodegradable poly(caprolactone-urea) urethane (POSS-PCL) were examined. Sterilization techniques included conventional steam sterilization (autoclaving), gamma irradiation, and disinfection via incubating with ethanol (EtOH) for 10 min or 24 h. After treatment, the samples were examined using gel permeation chromatography (GPC), attenuated total reflectance Fourier transform infrared spectroscopy, and tensiometry. Cytotoxicity was evaluated through the culture of endothelial progenitor cells and the efficacy of sterilization method was determined by incubating each sample in tryptone soya broth and fluid thioglycollate medium for cultivation of microorganisms. Although EtOH did not affect the material properties in any form, the samples were found to be nonsterile with microbial growth detected on each of the samples. Gamma irradiation was not only effective in sterilizing both POSS-PCU and POSS-PCL but also led to minor material degradation and displayed a cytotoxic effect on the cultured cells. Autoclaving was found to be the optimal sterilization technique for both solid and porous membranes of the nondegradable POSS-PCU samples as it was successful in sterilizing the samples, displayed no cytotoxic side effects and did not degrade the material. However, the biodegradable POSS-PCL was not able to withstand the harsh environment during autoclaving, resulting in it losing all structural integrity. Copyright © 2013 Wiley Periodicals, Inc., a Wiley Company.

  8. Infrared processing of foods

    USDA-ARS?s Scientific Manuscript database

    Infrared (IR) processing of foods has been gaining popularity over conventional processing in several unit operations, including drying, peeling, baking, roasting, blanching, pasteurization, sterilization, disinfection, disinfestation, cooking, and popping . It has shown advantages over conventional...

  9. A simple method for decomposition of peracetic acid in a microalgal cultivation system.

    PubMed

    Sung, Min-Gyu; Lee, Hansol; Nam, Kibok; Rexroth, Sascha; Rögner, Matthias; Kwon, Jong-Hee; Yang, Ji-Won

    2015-03-01

    A cost-efficient process devoid of several washing steps was developed, which is related to direct cultivation following the decomposition of the sterilizer. Peracetic acid (PAA) is known to be an efficient antimicrobial agent due to its high oxidizing potential. Sterilization by 2 mM PAA demands at least 1 h incubation time for an effective disinfection. Direct degradation of PAA was demonstrated by utilizing components in conventional algal medium. Consequently, ferric ion and pH buffer (HEPES) showed a synergetic effect for the decomposition of PAA within 6 h. On the contrary, NaNO3, one of the main components in algal media, inhibits the decomposition of PAA. The improved growth of Chlorella vulgaris and Synechocystis PCC6803 was observed in the prepared BG11 by decomposition of PAA. This process involving sterilization and decomposition of PAA should help cost-efficient management of photobioreactors in a large scale for the production of value-added products and biofuels from microalgal biomass.

  10. Evaluation of MALDI-TOF mass spectrometry and Sepsityper Kit™ for the direct identification of organisms from sterile body fluids in a Canadian pediatric hospital.

    PubMed

    Tadros, Manal; Petrich, Astrid

    2013-01-01

    Matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) can be used to identify bacteria directly from positive blood and sterile fluid cultures. The authors evaluated a commercially available kit - the Sepsityper Kit (Bruker Daltonik, Germany) - and MALDI-TOF MS for the rapid identification of organisms from 80 flagged positive blood culture broths, of which 73 (91.2%) were blood culture specimens and seven (8.7%) were cerebrospinal fluid specimens, in comparison with conventional identification methods. Correct identification to the genus and species levels was obtained in 75 of 80 (93.8%) and 39 of 50 (78%) blood culture broths, respectively. Applying the blood culture analysis module, a newly developed software tool, improved the species identification of Gram-negative organisms from 94.7% to 100% and of Gram-positive organisms from 66.7% to 70%. MALDI-TOF MS is a promising tool for the direct identification of organisms cultured from sterile sites.

  11. Effective Thermal Inactivation of the Spores of Bacillus cereus Biofilms Using Microwave.

    PubMed

    Park, Hyong Seok; Yang, Jungwoo; Choi, Hee Jung; Kim, Kyoung Heon

    2017-07-28

    Microwave sterilization was performed to inactivate the spores of biofilms of Bacillus cereus involved in foodborne illness. The sterilization conditions, such as the amount of water and the operating temperature and treatment time, were optimized using statistical analysis based on 15 runs of experimental results designed by the Box-Behnken method. Statistical analysis showed that the optimal conditions for the inactivation of B. cereus biofilms were 14 ml of water, 108°C of temperature, and 15 min of treatment time. Interestingly, response surface plots showed that the amount of water is the most important factor for microwave sterilization under the present conditions. Complete inactivation by microwaves was achieved in 5 min, and the inactivation efficiency by microwave was obviously higher than that by conventional steam autoclave. Finally, confocal laser scanning microscopy images showed that the principal effect of microwave treatment was cell membrane disruption. Thus, this study can contribute to the development of a process to control food-associated pathogens.

  12. Floating rGO-based black membranes for solar driven sterilization.

    PubMed

    Zhang, Yao; Zhao, Dengwu; Yu, Fan; Yang, Chao; Lou, Jinwei; Liu, Yanming; Chen, Yingying; Wang, Zhongyong; Tao, Peng; Shang, Wen; Wu, Jianbo; Song, Chengyi; Deng, Tao

    2017-12-14

    This paper presents a new steam sterilization approach that uses a solar-driven evaporation system at the water/air interface. Compared to the conventional solar autoclave, this new steam sterilization approach via interfacial evaporation requires no complex system design to bear high steam pressure. In such a system, a reduced graphene oxide/polytetrafluoroethylene composite membrane floating at the water/air interface serves as a light-to-heat conversion medium to harvest and convert incident solar light into localized heat. Such localized heat raises the temperature of the membrane substantially and helps generate steam with a temperature higher than 120 °C. A sterilization device that takes advantage of the interfacial solar-driven evaporation system was built and its successful sterilization capability was demonstrated through both chemical and biological sterilization tests. The interfacial evaporation-based solar driven sterilization approach offers a potential low cost solution to meet the need for sterilization in undeveloped areas that lack electrical power but have ample solar radiation.

  13. Cold atmospheric air plasma sterilization against spores and other microorganisms of clinical interest.

    PubMed

    Klämpfl, Tobias G; Isbary, Georg; Shimizu, Tetsuji; Li, Yang-Fang; Zimmermann, Julia L; Stolz, Wilhelm; Schlegel, Jürgen; Morfill, Gregor E; Schmidt, Hans-Ulrich

    2012-08-01

    Physical cold atmospheric surface microdischarge (SMD) plasma operating in ambient air has promising properties for the sterilization of sensitive medical devices where conventional methods are not applicable. Furthermore, SMD plasma could revolutionize the field of disinfection at health care facilities. The antimicrobial effects on Gram-negative and Gram-positive bacteria of clinical relevance, as well as the fungus Candida albicans, were tested. Thirty seconds of plasma treatment led to a 4 to 6 log(10) CFU reduction on agar plates. C. albicans was the hardest to inactivate. The sterilizing effect on standard bioindicators (bacterial endospores) was evaluated on dry test specimens that were wrapped in Tyvek coupons. The experimental D(23)(°)(C) values for Bacillus subtilis, Bacillus pumilus, Bacillus atrophaeus, and Geobacillus stearothermophilus were determined as 0.3 min, 0.5 min, 0.6 min, and 0.9 min, respectively. These decimal reduction times (D values) are distinctly lower than D values obtained with other reference methods. Importantly, the high inactivation rate was independent of the material of the test specimen. Possible inactivation mechanisms for relevant microorganisms are briefly discussed, emphasizing the important role of neutral reactive plasma species and pointing to recent diagnostic methods that will contribute to a better understanding of the strong biocidal effect of SMD air plasma.

  14. Cold Atmospheric Air Plasma Sterilization against Spores and Other Microorganisms of Clinical Interest

    PubMed Central

    Isbary, Georg; Shimizu, Tetsuji; Li, Yang-Fang; Zimmermann, Julia L.; Stolz, Wilhelm; Schlegel, Jürgen; Morfill, Gregor E.; Schmidt, Hans-Ulrich

    2012-01-01

    Physical cold atmospheric surface microdischarge (SMD) plasma operating in ambient air has promising properties for the sterilization of sensitive medical devices where conventional methods are not applicable. Furthermore, SMD plasma could revolutionize the field of disinfection at health care facilities. The antimicrobial effects on Gram-negative and Gram-positive bacteria of clinical relevance, as well as the fungus Candida albicans, were tested. Thirty seconds of plasma treatment led to a 4 to 6 log10 CFU reduction on agar plates. C. albicans was the hardest to inactivate. The sterilizing effect on standard bioindicators (bacterial endospores) was evaluated on dry test specimens that were wrapped in Tyvek coupons. The experimental D23°C values for Bacillus subtilis, Bacillus pumilus, Bacillus atrophaeus, and Geobacillus stearothermophilus were determined as 0.3 min, 0.5 min, 0.6 min, and 0.9 min, respectively. These decimal reduction times (D values) are distinctly lower than D values obtained with other reference methods. Importantly, the high inactivation rate was independent of the material of the test specimen. Possible inactivation mechanisms for relevant microorganisms are briefly discussed, emphasizing the important role of neutral reactive plasma species and pointing to recent diagnostic methods that will contribute to a better understanding of the strong biocidal effect of SMD air plasma. PMID:22582068

  15. Determination of fatty acid composition and quality characteristics of oils from palm fruits using solvent extraction

    NASA Astrophysics Data System (ADS)

    Kasmin, Hasimah; Lazim, Azwan Mat; Awang, Roila

    2015-09-01

    Palm oil contains about 45% of saturated palmitic acid and 39% of mono-unsaturated oleic acid. Investigations made in the past to trace the fatty acid composition in palm revealed that ripeness of fresh fruit bunch (FFB) affect oil composition. However, there is no evidence that processing operations affect oil composition, although different stage of processing does affect the quality of oil extracted. An improved method for sterilizing the oil palm fruits by dry heating, followed by oil extraction has been studied. This method eliminates the use of water, thus, increasing the extraction of lipid soluble. The objective of this study is to determine the possibility production of palm oil with different fatty acid composition (FAC) as well as the changes in quality from conventional milling. The unripe and ripe FFB were collected, sterilized and extracted using different method of solvent extraction. Preliminary data have shown that variation in FAC will also alter the physical and chemical properties of the oil extracted.

  16. The sterilization of endodontic hand files.

    PubMed

    Hurtt, C A; Rossman, L E

    1996-06-01

    Several different methods of file sterilization were analyzed to determine the best method of providing complete file sterility, including the metal shaft and plastic handle. Six test groups of 15 files were studied using Bacillus stearothermophilus as the test organism. Groups were "sterilized" by glutaraldehyde immersion, steam autoclaving, and various techniques of salt sterilization. Only proper steam autoclaving reliably produced completely sterile instruments. Salt sterilization and glutaraldehyde solutions may not be adequate sterilization methods for endodontic hand files and should not be relied on to provide completely sterile instruments.

  17. Comparison of Candida Albicans Adherence to Conventional Acrylic Denture Base Materials and Injection Molding Acrylic Materials

    PubMed Central

    Aslanimehr, Masoomeh; Rezvani, Shirin; Mahmoudi, Ali; Moosavi, Najmeh

    2017-01-01

    Statement of the Problem: Candida species are believed to play an important role in initiation and progression of denture stomatitis. The type of the denture material also influences the adhesion of candida and development of stomatitis. Purpose: The aim of this study was comparing the adherence of candida albicans to the conventional and injection molding acrylic denture base materials. Materials and Method: Twenty injection molding and 20 conventional pressure pack acrylic discs (10×10×2 mm) were prepared according to their manufacturer’s instructions. Immediately before the study, samples were placed in sterile water for 3 days to remove residual monomers. The samples were then sterilized using an ultraviolet light unit for 10 minutes. 1×108 Cfu/ml suspension of candida albicans ATCC-10231 was prepared from 48 h cultured organism on sabouraud dextrose agar plates incubated at 37oC. 100 μL of this suspension was placed on the surface of each disk. After being incubated at 37oC for 1 hour, the samples were washed with normal saline to remove non-adherent cells. Attached cells were counted using the colony count method after shaking at 3000 rmp for 20 seconds. Finally, each group was tested for 108 times and the data were statistically analyzed by t-test. Results: Quantitative analysis revealed that differences in colony count average of candida albicans adherence to conventional acrylic materials (8.3×103) comparing to injection molding acrylic resins (6×103) were statistically significant (p<0.001). Conclusion: Significant reduction of candida albicans adherence to the injection acrylic resin materials makes them valuable for patients with high risk of denture stomatitis. PMID:28280761

  18. Effect of Dielectric and Liquid on Plasma Sterilization Using Dielectric Barrier Discharge Plasma

    PubMed Central

    Mastanaiah, Navya; Johnson, Judith A.; Roy, Subrata

    2013-01-01

    Plasma sterilization offers a faster, less toxic and versatile alternative to conventional sterilization methods. Using a relatively small, low temperature, atmospheric, dielectric barrier discharge surface plasma generator, we achieved ≥6 log reduction in concentration of vegetative bacterial and yeast cells within 4 minutes and ≥6 log reduction of Geobacillus stearothermophilus spores within 20 minutes. Plasma sterilization is influenced by a wide variety of factors. Two factors studied in this particular paper are the effect of using different dielectric substrates and the significance of the amount of liquid on the dielectric surface. Of the two dielectric substrates tested (FR4 and semi-ceramic (SC)), it is noted that the FR4 is more efficient in terms of time taken for complete inactivation. FR4 is more efficient at generating plasma as shown by the intensity of spectral peaks, amount of ozone generated, the power used and the speed of killing vegetative cells. The surface temperature during plasma generation is also higher in the case of FR4. An inoculated FR4 or SC device produces less ozone than the respective clean devices. Temperature studies show that the surface temperatures reached during plasma generation are in the range of 30°C–66°C (for FR4) and 20°C–49°C (for SC). Surface temperatures during plasma generation of inoculated devices are lower than the corresponding temperatures of clean devices. pH studies indicate a slight reduction in pH value due to plasma generation, which implies that while temperature and acidification may play a minor role in DBD plasma sterilization, the presence of the liquid on the dielectric surface hampers sterilization and as the liquid evaporates, sterilization improves. PMID:23951023

  19. Effect of dielectric and liquid on plasma sterilization using dielectric barrier discharge plasma.

    PubMed

    Mastanaiah, Navya; Johnson, Judith A; Roy, Subrata

    2013-01-01

    Plasma sterilization offers a faster, less toxic and versatile alternative to conventional sterilization methods. Using a relatively small, low temperature, atmospheric, dielectric barrier discharge surface plasma generator, we achieved ≥ 6 log reduction in concentration of vegetative bacterial and yeast cells within 4 minutes and ≥ 6 log reduction of Geobacillus stearothermophilus spores within 20 minutes. Plasma sterilization is influenced by a wide variety of factors. Two factors studied in this particular paper are the effect of using different dielectric substrates and the significance of the amount of liquid on the dielectric surface. Of the two dielectric substrates tested (FR4 and semi-ceramic (SC)), it is noted that the FR4 is more efficient in terms of time taken for complete inactivation. FR4 is more efficient at generating plasma as shown by the intensity of spectral peaks, amount of ozone generated, the power used and the speed of killing vegetative cells. The surface temperature during plasma generation is also higher in the case of FR4. An inoculated FR4 or SC device produces less ozone than the respective clean devices. Temperature studies show that the surface temperatures reached during plasma generation are in the range of 30°C-66 °C (for FR4) and 20 °C-49 °C (for SC). Surface temperatures during plasma generation of inoculated devices are lower than the corresponding temperatures of clean devices. pH studies indicate a slight reduction in pH value due to plasma generation, which implies that while temperature and acidification may play a minor role in DBD plasma sterilization, the presence of the liquid on the dielectric surface hampers sterilization and as the liquid evaporates, sterilization improves.

  20. Laser assisted irrigation and hand irrigation for root canal decontamination: a comparison

    NASA Astrophysics Data System (ADS)

    Olivi, M.; Stefanucci, M.; Todea, C.

    2014-01-01

    Aim: to compare the bactericidal efficiency of conventional method and LAI for root canal decontamination. Material and method: 22 human single root teeth, extracted for periodontal problems, mechanically prepared up to ISO 25 at the working lenght were divided in 2 groups: after sterilization, the teeth were infected with enterococcus faecalis and incubated for 4 weeks. Group A: 10 teeth were irrigated with conventional hand technique (CI): 3ml of 5% NaClO were used for two times of 30s each and after washing with sterile bi-distilled water for 20s, a final irrigation was performed with 3ml of 17% EDTA. Group B: 10 teeth were irrigated with 3ml of NaClO and activated by erbium laser, two cycles of 30s; also the final irrigation with 3ml of 17% EDTA was activated by erbium laser. In both the groups a resting time of 30s was used between the two sessions to allow the reaction rate of NaClO. The Erbium laser 2940 nm (LightWalker AT, Fotona; Lublijana, Slovenia) was used with 50microsecond pulse duration, at 15Hz, 20mJ, with a 600micron PIPS tip. Two samples were used as positive and negative control.

  1. Sterilization of endoscopic instruments.

    PubMed

    Sabnis, Ravindra B; Bhattu, Amit; Vijaykumar, Mohankumar

    2014-03-01

    Sterilization of endoscopic instruments is an important but often ignored topic. The purpose of this article is to review the current literature on the sterilization of endoscopic instruments and elaborate on the appropriate sterilization practices. Autoclaving is an economic and excellent method of sterilizing the instruments that are not heat sensitive. Heat sensitive instruments may get damaged with hot sterilization methods. Several new endoscopic instruments such as flexible ureteroscopes, chip on tip endoscopes, are added in urologists armamentarium. Many of these instruments are heat sensitive and hence alternative efficacious methods of sterilization are necessary. Although ethylene oxide and hydrogen peroxide are excellent methods of sterilization, they have some drawbacks. Gamma irradiation is mainly for disposable items. Various chemical agents are widely used even though they achieve high-level disinfection rather than sterilization. This article reviews various methods of endoscopic instrument sterilization with their advantages and drawbacks. If appropriate sterilization methods are adopted, then it not only will protect patients from procedure-related infections but prevent hypersensitive allergic reactions. It will also protect instruments from damage and increase its longevity.

  2. Effect of autoclaving on the surfaces of TiN -coated and conventional nickel-titanium rotary instruments.

    PubMed

    Spagnuolo, G; Ametrano, G; D'Antò, V; Rengo, C; Simeone, M; Riccitiello, F; Amato, M

    2012-12-01

    To evaluate the effects of repeated autoclave sterilization cycles on surface topography of conventional nickel-titanium ( NiTi ) and titanium nitride ( TiN )-coated rotary instruments. A total of 60 NiTi rotary instruments, 30 ProTaper (Dentsply Maillefer) and 30 TiN -coated AlphaKite (Komet/Gebr. Brasseler), were analysed. Instruments were evaluated in the as-received condition and after 1, 5 and 10 sterilization cycles. After sterilization, the samples were observed using scanning electron microscope (SEM), and surface chemical analysis was performed on each instrument with energy dispersive X-ray spectroscopy (EDS). Moreover, the samples were analysed by atomic force microscopy (AFM), and roughness average (Ra) and the root mean square value (RMS) of the scanned surface profiles were recorded. Data were analysed by means of anova followed by Tukey's test. Scanning electron microscope observations revealed the presence of pitting and deep milling marks in all instruments. EDS analysis confirmed that both types of instruments were composed mainly of nickel and titanium, whilst AlphaKite had additional nitride. After multiple autoclave sterilization cycles, SEM examinations revealed an increase in surface alterations, and EDS values indicated changes in chemical surface composition in all instruments. Ra and RMS values of ProTaper significantly increased after 5 (P = 0.006) and 10 cycles (P = 0.002) with respect to the as-received instruments, whilst AlphaKite showed significant differences compared with the controls after 10 cycles (P = 0.03). Multiple autoclave sterilization cycles modified the surface topography and chemical composition of conventional and TiN -coated NiTi rotary instruments. © 2012 International Endodontic Journal.

  3. Non-destructive vacuum decay method for pre-filled syringe closure integrity testing compared with dye ingress testing and high-voltage leak detection.

    PubMed

    Simonetti, Andrea; Amari, Filippo

    2015-01-01

    In reaction to the limitations of the traditional sterility test methods, in 2008, the U.S. Food and Drug Administration issued the guidance "Container and Closure System Integrity Testing in Lieu of Sterility Testing as a Component of the Stability Protocol for Sterile Products" encouraging sterile drug manufacturers to use properly validated physical methods, apart from conventional microbial challenge testing, to confirm container closure integrity as part of the stability protocol. The case study presented in this article investigated the capability of four container closure integrity testing methods to detect simulated defects of different sizes and types on glass syringes, prefilled both with drug product intended for parenteral administration and sterile water. The drug product was a flu vaccine (Agrippal, Novartis Vaccines, Siena, Italy). Vacuum decay, pharmacopoeial dye ingress test, Novartis specific dye ingress test, and high-voltage leak detection were, in succession, the methods involved in the comparative studies. The case study execution was preceded by the preparation of two independent sets of reference prefilled syringes, classified, respectively, as examples of conforming to closure integrity requirements (negative controls) and as defective (positive controls). Positive controls were, in turn, split in six groups, three of with holes laser-drilled through the prefilled syringe glass barrel, while the other three with capillary tubes embedded in the prefilled syringe plunger. These reference populations were then investigated by means of validated equipment used for container closure integrity testing of prefilled syringe commercial production; data were collected and analyzed to determine the detection rate and the percentage of false results. Results showed that the vacuum decay method had the highest performance in terms of detection sensitivity and also ensured the best reliability and repeatability of measurements. An innovative technical solution, preventing possible prefilled syringe plunger movement during container closure integrity testing execution, is presented as well. The growing need to meet sterile drug products' regulatory, quality, and safety expectations has progressively driven new developments and improvements both in container closure integrity testing methods and in the respective equipment, over the last years. Indeed, container closure integrity testing establishes the container closure system capability to provide required protection to the drug product and to demonstrate maintenance of product sterility over its shelf life. This article describes the development of four container closure integrity testing approaches for the evaluation of glass prefilled syringe closure integrity, including two destructive (pharmacopoeial and Novartis specific dye ingress test) and two non-destructive (vacuum decay and high-voltage leak detection) methods. The important finding from the validation of comparative studies was that the vacuum decay method resulted in the most effective, reliable and repeatable detection of defective samples, whether the defect was exposed to sterile water, to drug product, or to air. Complete sets of known defects were created for this purpose (5 μm, 10 μm, 20 μm certified leakages by laser drilled holes and capillary tubes). All investigations and studies were conducted at Bonfiglioli Engineering S.r.l. (Vigarano Pieve, Ferrara, Italy) and at Novartis Vaccines (Sovicille, Siena, Italy). © PDA, Inc. 2015.

  4. [Sterilization effect analysis of B-class pulsation table top vacuum sterilizer to dental handpieces].

    PubMed

    Zeng, Shu-Rong; Jiang, Bo; Xiao, Xiao-Rong

    2007-06-01

    Discuss sterilization effect of B-class pulsation table top vacuum pressure steam sterilizer for dental handpiece. Analysis selection of sterilizer for dental handpiece and sterilization management processes and sterilization effect monitoring, evaluation of monitoring result and effective sterilization method. The B-class pulsation table top vacuum pressure steam sterilizer to dental handpiece in West China Stomatological Hospital of Sichuan University met the requirement of the chemical and biological monitoring. Its efficiency of sterilization was 100%. The results of aerobic culture, anaerobic culture, B-type hepatitis mark monitoring to sterilized dental handpiece were negative. It is effective method for dental handpiece sterilization to use B-class pulsation table top vacuum pressure steam sterilizer.

  5. Chapter 17 Sterile Plate-Based Vitrification of Adherent Human Pluripotent Stem Cells and Their Derivatives Using the TWIST Method.

    PubMed

    Neubauer, Julia C; Stracke, Frank; Zimmermann, Heiko

    2017-01-01

    Due to their high biological complexity, e.g., their close cell-to-cell contacts, cryopreservation of human pluripotent stem cells with standard slow-rate protocols often is inefficient and can hardly be standardized. Vitrification that means ultrafast freezing already showed very good viability and recovery rates for this sensitive cell system, but is only applicable for low cell numbers, bears a high risk of contamination, and can hardly be implemented under GxP regulations. In this chapter, a sterile plate-based vitrification method for adherent pluripotent stem cells and their derivatives is presented based on a procedure and device for human embryonic stem cells developed by Beier et al. (Cryobiology 66:8-16, 2013). This protocol overcomes the limitations of conventional vitrification procedures resulting in the highly efficient preservation of ready-to-use adherent pluripotent stem cells with the possibility of vitrifying cells in multi-well formats for direct application in high-throughput screenings.

  6. Sterilization: A Review and Update.

    PubMed

    Moss, Chailee; Isley, Michelle M

    2015-12-01

    Sterilization is a frequently used method of contraception. Female sterilization is performed 3 times more frequently than male sterilization, and it can be performed immediately postpartum or as an interval procedure. Methods include mechanical occlusion, coagulation, or tubal excision. Female sterilization can be performed using an abdominal approach, or via laparoscopy or hysteroscopy. When an abdominal approach or laparoscopy is used, sterilization occurs immediately. When hysteroscopy is used, tubal occlusion occurs over time, and additional testing is needed to confirm tubal occlusion. Comprehensive counseling about sterilization should include discussion about male sterilization (vasectomy) and long-acting reversible contraceptive methods. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Sterilization/disinfection using reduced-pressure plasmas: some differences between direct exposure of bacterial spores to a discharge and their exposure to a flowing afterglow

    NASA Astrophysics Data System (ADS)

    Moisan, M.; Levif, P.; Séguin, J.; Barbeau, J.

    2014-07-01

    The use of plasma for sterilization or disinfection offers a promising alternative to conventional steam or chemical approaches. Plasma can operate at temperatures less damaging to some heat-sensitive medical devices and, in contrast to chemicals, can be non-toxic and non-polluting for the operator and the environment, respectively. Direct exposure to the gaseous discharge (comprising an electric field and ions/electrons) or exposure to its afterglow (no E-field) can both be envisaged a priori, since these two methods can achieve sterility. However, important issues must be considered besides the sterility goal. Direct exposure to the discharge, although yielding a faster inactivation of microorganisms, is shown to be potentially more aggressive to materials and sometimes subjected to the shadowing effect that precludes the sterilization of complex-form items. These two drawbacks can be successfully minimized with an adequate flowing-afterglow exposure. Most importantly, the current paper shows that direct exposure to the discharge can lead to the dislodgment and release of viable microorganisms from their substratum. Such a phenomenon could be responsible for the recontamination of sterilized devices as well as possible contamination of the ambient surroundings, additionally yielding an erroneous over-appreciation of the inactivation efficiency. The operation of the N2-O2 flowing afterglow system being developed in our group is such that there are no ions and electrons left in the process chamber (late-afterglow regime) in full contrast with their presence in the discharge. The dislodgment and release of spores could be attributed, based on the literature, to their electrostatic charging by electrons, leading to an (outward) electrostatic stress that exceeds the adhesion of the spores on their substrate.

  8. A Bayesian Approach to Determination of F, D, and Z Values Used in Steam Sterilization Validation.

    PubMed

    Faya, Paul; Stamey, James D; Seaman, John W

    2017-01-01

    For manufacturers of sterile drug products, steam sterilization is a common method used to provide assurance of the sterility of manufacturing equipment and products. The validation of sterilization processes is a regulatory requirement and relies upon the estimation of key resistance parameters of microorganisms. Traditional methods have relied upon point estimates for the resistance parameters. In this paper, we propose a Bayesian method for estimation of the well-known D T , z , and F o values that are used in the development and validation of sterilization processes. A Bayesian approach allows the uncertainty about these values to be modeled using probability distributions, thereby providing a fully risk-based approach to measures of sterility assurance. An example is given using the survivor curve and fraction negative methods for estimation of resistance parameters, and we present a means by which a probabilistic conclusion can be made regarding the ability of a process to achieve a specified sterility criterion. LAY ABSTRACT: For manufacturers of sterile drug products, steam sterilization is a common method used to provide assurance of the sterility of manufacturing equipment and products. The validation of sterilization processes is a regulatory requirement and relies upon the estimation of key resistance parameters of microorganisms. Traditional methods have relied upon point estimates for the resistance parameters. In this paper, we propose a Bayesian method for estimation of the critical process parameters that are evaluated in the development and validation of sterilization processes. A Bayesian approach allows the uncertainty about these parameters to be modeled using probability distributions, thereby providing a fully risk-based approach to measures of sterility assurance. An example is given using the survivor curve and fraction negative methods for estimation of resistance parameters, and we present a means by which a probabilistic conclusion can be made regarding the ability of a process to achieve a specified sterility criterion. © PDA, Inc. 2017.

  9. Patient-provider conversations about sterilization: A qualitative analysis.

    PubMed

    Kimport, Katrina; Dehlendorf, Christine; Borrero, Sonya

    2017-03-01

    Although female sterilization is the second most commonly used contraceptive method in the US, research suggests that providers may serve as barriers to desired sterilization. We conducted a modified grounded theory analysis of audio-recorded contraceptive counseling visits with 52 women who specified on a previsit survey that they wanted no future children and a supplemental analysis of visits with 14 women who wanted or were unsure about future children in which sterilization was mentioned. Sterilization was discussed in only 19 of the 52 visits, primarily with patients who were older women with children. Although some framed sterilization positively, many clinicians discouraged patients from pursuing sterilization, encouraging them instead to use long-acting reversible methods and framing the permanence of sterilization as undesirable. In the 33 remaining sessions, sterilization was not mentioned, and clinicians largely failed to solicit patients' future reproductive intentions. We found no clear patterns regarding discussion of sterilization in the 14 supplemental cases. Clinicians did not discuss sterilization with all patients for whom it might have been appropriate and thus missed opportunities to discuss sterilization as part of the full range of appropriate methods. When they did discuss sterilization, they only infrequently presented the method in positive ways and more commonly encouraged patients to choose a long-acting reversible method instead. Clinicians may want to reflect on their counseling practices around sterilization to ensure that counseling is centered on patient preferences, rather than driven by their own assumptions about the desirability of reversibility. Clinicians often fail to discuss sterilization as a contraceptive option with potentially appropriate candidates and, when they do, often discourage its selection. Clinicians should consider assessing reproductive intentions to ensure that potentially relevant methods are included in counseling. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Hysteroscopic Tubal Sterilization

    PubMed Central

    McMartin, K

    2013-01-01

    Background Hysteroscopic tubal sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. The procedures involves non-surgical placement of permanent microinserts into both fallopian tubes. Patients must use alternative contraception for at least 3 months postprocedure until tubal occlusion is confirmed. Compared to tubal ligation, potential advantages of the hysteroscopic procedure are that it can be performed in 10 minutes in an office setting without the use of general or even local anesthesia. Objective The objective of this analysis was to determine the effectiveness and safety of hysteroscopic tubal sterilization compared with tubal ligation for permanent female sterilization. Data Sources A standard systematic literature search was conducted for studies published from January 1, 2008, until December 11, 2012. Review Methods Observational studies, randomized controlled trials (RCTs), systematic reviews and meta-analyses with 1 month or more of follow-up were examined. Outcomes included failure/pregnancy rates, adverse events, and patient satisfaction. Results No RCTs were identified. Two systematic reviews covered 22 observational studies of hysteroscopic sterilization. Only 1 (N = 93) of these 22 studies compared hysteroscopic sterilization to laparoscopic tubal ligation. Two other noncomparative case series not included in the systematic reviews were also identified. In the absence of comparative studies, data on tubal ligation were derived for this analysis from the CREST study, a large, multicentre, prospective, noncomparative observational study in the United States (GRADE low). Overall, hysteroscopic sterilization is associated with lower pregnancy rates and lower complication rates compared to tubal ligation. No deaths have been reported for hysteroscopic sterilization. Limitations A lack of long-term follow-up for hysteroscopic sterilization and a paucity of studies that directly compare the two procedures limit this assessment. In addition, optimal placement of the microinsert at the time of hysteroscopy varied among studies. Conclusions Hysteroscopic sterilization is associated with: lower pregnancy rates compared to tubal ligation (GRADE very low) lower complication rates compared to tubal ligation (GRADE very low) no significant improvement in patient satisfaction compared to tubal ligation (GRADE very low) Plain Language Summary Hysteroscopic tubal sterilization is a minimally invasive alternative to conventional tubal ligation for women who want a permanent method of contraception. Both approaches involve closing off the fallopian tubes, preventing the egg from moving down the tube and the sperm from reaching the egg. Tubal ligation is a surgical procedure to tie or seal the fallopian tubes, and it usually requires general anesthesia. In contrast, hysteroscopic tubal sterilization can be performed in 10 minutes in an office setting without general or even local anesthesia. A tiny device called a microinsert is inserted into each fallopian tube through the vagina, cervix, and uterus without surgery. An instrument called a hysteroscope allows the doctor to see inside the body for the procedure. Once the microinserts are in place, scar tissue forms around them and blocks the fallopian tubes. Health Quality Ontario conducted a review of the effectiveness and safety of hysteroscopic tubal sterilization compared to tubal ligation. This review indicates that hysteroscopic tubal sterilization is associated with: lower pregnancy rates compared to tubal ligation lower complication rates compared to tubal ligation no significant improvement in patient satisfaction compared to tubal ligation However, we found a number of limitations to the studies available on hysteroscopic tubal sterilization. Among other concerns, most studies did not include long-term follow-up and only 1 study directly compared hysteroscopic tubal sterilization to tubal ligation. PMID:24228084

  11. Stuffed Animals in the Operating Room: A Reservoir of Bacteria With a Simple Solution.

    PubMed

    Held, Michael; Mignemi, Megan; O'Rear, Lynda; Wise, Michelle; Zane, Gabriella; Murphy Zane, M Siobhan; Schoenecker, Jonathan G

    2015-12-01

    Despite hand washing and other protocols surgical-site infections (SSIs) have not been eliminated. This implies that either current measures are not effective or there are alternative sources of bacterial exposure to the surgical wound. In this study we tested the hypothesis that stuffed animals or other items allowed to accompany pediatric patients to the operating room as a way to ease anxiety may represent a reservoir of bacteria. Stuffed animals brought into the operating room and stuffed animals that were washed and dried in a conventional washer/dryer and placed in clean sealable plastic bags were swabbed and bacterial colonies were quantified. Results were reported as no growth, light growth, moderate growth, and heavy growth. All stuffed animals showed bacterial growth. A total of 79% of stuffed animals were effectively "sterilized" by a single wash and dry cycle in a conventional home washer/dryer. Sterilized stuffed animals remained sterile after being packed in a sealed bag for 24 hours. These results indicate that items of comfort, such as stuffed animals, brought into the operating room with a benevolent purpose may represent a reservoir of bacteria that could lead to unwanted SSI. Washing an item of comfort 1 day before surgery effectively sterilizes that item of comfort. Future studies will be needed to determine a correlation between "culture positive" stuffed animals and SSI or if providing a child with a "sterile" stuffed animal reduces SSI.

  12. Review of surface steam sterilization for validation purposes.

    PubMed

    van Doornmalen, Joost; Kopinga, Klaas

    2008-03-01

    Sterilization is an essential step in the process of producing sterile medical devices. To guarantee sterility, the process of sterilization must be validated. Because there is no direct way to measure sterility, the techniques applied to validate the sterilization process are based on statistical principles. Steam sterilization is the most frequently applied sterilization method worldwide and can be validated either by indicators (chemical or biological) or physical measurements. The steam sterilization conditions are described in the literature. Starting from these conditions, criteria for the validation of steam sterilization are derived and can be described in terms of physical parameters. Physical validation of steam sterilization appears to be an adequate and efficient validation method that could be considered as an alternative for indicator validation. Moreover, physical validation can be used for effective troubleshooting in steam sterilizing processes.

  13. Comparison of liquid chemical sterilization with peracetic acid and ethylene oxide sterilization for long narrow lumens.

    PubMed

    Alfa, M J; DeGagne, P; Olson, N; Hizon, R

    1998-10-01

    The aim of this study was to determine how well peracetic acid liquid chemical sterilization (LCPAS) killed test organisms in the presence of 10% fetal bovine serum and 0.65% salt challenge (RPMI-S) compared with a 100% ethylene oxide (ETO) sterilizer and an ETO hydrochlorofluorocarbon (ETO-HCFC) sterilization method with long (125 cm), narrow (3-mm internal diameter) flexible lumens as the test carrier. The inoculated lumens were dried overnight before processing. The test organisms included Mycobacterium chelonei, Enterococcus faecalis, and Bacillus subtilis. For all 3 organisms tested, the LCPAS process resulted in a 6 log10 reduction in bacterial load compared with a 2.5 log10 to 6 log10 reduction for the 100% ETO and ETO-HCFC sterilizers. Sterilization was achieved for 100%, 61%, and 67% of the lumen test carriers for the LCPAS, 100% ETO, and ETO-HCFC sterilizers, respectively. The data indicate that of the sterilization methods evaluated, LCPAS was the most effective for sterilizing narrow flexible lumens in the presence of residual inorganic and organic soil. This effectiveness was achieved through a combination of organism wash-off and peracetic acid sterilant killing of organisms. Salt was the major compounding factor for effective ETO gas sterilization, because carriers inoculated with organisms in 10% fetal bovine serum alone all were sterilized by both 100% ETO and ETO-HCFC sterilization methods. Our data support the critical need to ensure adequate precleaning of narrow flexible lumen endoscopes before any sterilization method.

  14. Influence of microwave sterilization on the cutting capacity of carbide burs.

    PubMed

    Fais, Laiza Maria Grassi; Pinelli, Lígia Antunes Pereira; Adabo, Gelson Luis; Silva, Regina Helena Barbosa Tavares da; Marcelo, Caroline Canhizares; Guaglianoni, Dalton Geraldo

    2009-01-01

    This study compared the cutting capacity of carbide burs sterilized with microwaves and traditional sterilization methods. Sixty burs were divided into 5 groups according to the sterilization methods: dry heat (G1), autoclave (G2), microwave irradiation (G3), glutaraldehyde (G4) or control - no sterilization (G5). The burs were used to cut glass plates in a cutting machine set for twelve 2.5-min periods and, after each period, they were sterilized (except G5) following the protocol established for each group. The cutting capacity of the burs was determined by a weight-loss method. Data were analyzed statistically by Kruskal-Wallis and Dunn's test. The means of the cutting amount performed by each group after the 12 periods were G1 = 0.2167 +/- 0.0627 g; G2 = 0.2077 +/- 0.0231 g; G3 = 0.1980 +/- 0.0326 g; G4 = 0.1203 +/- 0.0459 g; G5 = 0.2642 +/- 0.0359 g. There were statistically significant differences among the groups (p<0.05); only dry heat sterilization was similar to the control. Sterilization by dry heat was the method that least affected the cutting capacity of the carbide burs and microwave sterilization was not better than traditional sterilization methods.

  15. INFLUENCE OF MICROWAVE STERILIZATION ON THE CUTTING CAPACITY OF CARBIDE BURS

    PubMed Central

    Fais, Laiza Maria Grassi; Pinelli, Lígia Antunes Pereira; Adabo, Gelson Luis; da Silva, Regina Helena Barbosa Tavares; Marcelo, Caroline Canhizares; Guaglianoni, Dalton Geraldo

    2009-01-01

    Objective: This study compared the cutting capacity of carbide burs sterilized with microwaves and traditional sterilization methods. Material and Methods: Sixty burs were divided into 5 groups according to the sterilization methods: dry heat (G1), autoclave (G2), microwave irradiation (G3), glutaraldehyde (G4) or control – no sterilization (G5). The burs were used to cut glass plates in a cutting machine set for twelve 2.5-min periods and, after each period, they were sterilized (except G5) following the protocol established for each group. The cutting capacity of the burs was determined by a weight-loss method. Data were analyzed statistically by Kruskal-Wallis and Dunn's test. Results: The means of the cutting amount performed by each group after the 12 periods were G1 = 0.2167 ± 0.0627 g; G2 = 0.2077 ± 0.0231 g; G3 = 0.1980 ± 0.0326 g; G4 = 0.1203 ± 0.0459 g; G5 = 0.2642 ± 0.0359 g. There were statistically significant differences among the groups (p<0.05); only dry heat sterilization was similar to the control. Conclusion: Sterilization by dry heat was the method that least affected the cutting capacity of the carbide burs and microwave sterilization was not better than traditional sterilization methods. PMID:20027431

  16. Fluorimetric Detection of a Bacillus stearothermophilus Spore-Bound Enzyme, α-d-Glucosidase, for Rapid Indication of Flash Sterilization Failure

    PubMed Central

    Vesley, Donald; Langholz, Ann C.; Rohlfing, Stephen R.; Foltz, William E.

    1992-01-01

    A biological indicator based on fluorimetric detection within 60 min of a Bacillus stearothermophilus spore-bound enzyme, α-d-glucosidase, has been developed. Results indicate that the enzyme survived slightly longer than spores observed after 24 h of incubation. The new system shows promise for evaluating flash sterilization cycles within 60 min compared with conventional 24-h systems. PMID:16348654

  17. A system for the rapid detection of bacterial contamination in cell-based therapeutica

    NASA Astrophysics Data System (ADS)

    Bolwien, Carsten; Erhardt, Christian; Sulz, Gerd; Thielecke, Hagen; Johann, Robert; Pudlas, Marieke; Mertsching, Heike; Koch, Steffen

    2010-02-01

    Monitoring the sterility of cell or tissue cultures is of major concern, particularly in the fields of regenerative medicine and tissue engineering when implanting cells into the human body. Our sterility-control system is based on a Raman micro-spectrometer and is able to perform fast sterility testing on microliters of liquid samples. In conventional sterility control, samples are incubated for weeks to proliferate the contaminants to concentrations above the detection limit of conventional analysis. By contrast, our system filters particles from the liquid sample. The filter chip fabricated in microsystem technology comprises a silicon nitride membrane with millions of sub-micrometer holes to retain particles of critical sizes and is embedded in a microfluidic cell specially suited for concomitant microscopic observation. After filtration, identification is carried out on the single particle level: image processing detects possible contaminants and prepares them for Raman spectroscopic analysis. A custom-built Raman-spectrometer-attachment coupled to the commercial microscope uses 532nm or 785nm Raman excitation and records spectra up to 3400cm-1. In the final step, the recorded spectrum of a single particle is compared to an extensive library of GMP-relevant organisms, and classification is carried out based on a support vector machine.

  18. Trends of Various Techniques of Tubectomy: A Five Year Study in a Tertiary Institute

    PubMed Central

    Prasanna, Naveen; Channabasappa, Ramalingappa Antartani

    2016-01-01

    Introduction Female sterilization is one of the best and effective methods of contraception for women who have completed their family. Tubectomy during caesarean operation and minilaparotomy are popular methods in developing countries whereas laparoscopic sterilization and hysteroscopic tubal occlusion are the preferred methods in developed countries. Aim To know the trends, incidence and immediate complications of methods of female sterilizations performed at our institute. Materials and Methods This is a retrospective analytical study conducted at our tertiary care centre from January 2010 to December 2014 in Karnataka Institute of Medical Sciences, Hubli, Karnataka. The case files of all the patients who underwent sterilization were taken from the medical records section and reviewed in detail. The cases were grouped as caesarean tubectomy, minilaparotomy and laparoscopic sterilization, based on the abdominal entry. For minilaparotomy and during caesarean tubectomy, modified pomeroy’s technique was used. For laparoscopic sterilization, falope rings were used. Data was analysed by Karl Pearson’s correlation co-efficient method and Chi-Square test. The p-value < 0.05 was considered significant. Results Out of 5442 cases of female sterilization, 2872 underwent caesarean tubectomy, remaining half underwent minilaparotomy (1306) and laparoscopic sterilization (1264). Sterilizations were significantly more during puerperal period (caesarean tubectomy + post abortal + postpartum) compared to interval period. There was an increasing trend in caesarean tubectomy and laparoscopic sterilization. There were 11 procedure related complications in the laparoscopic sterilization, one in caesarean tubectomy and none in minilaparotomy. Two deaths were reported in minilaparotomy, one in laparoscopic sterilization and four in the caesarean tubectomy, which were due to septicaemia. Conclusion An increasing trend in caesarean tubectomy and laparoscopic sterilization is seen in this study. Female sterilization should be individualized based on the timing, place and surgeons experience. Sepsis is a major cause of death and asepsis could be compromised when female sterilization is done in large numbers in camps. Hence target related approach towards female sterilization should be avoided. Laparoscopic sterilization has more procedure related complications, which can be better handled in tertiary care centres. PMID:26894125

  19. Sterilization in Finland: from eugenics to contraception.

    PubMed

    Hemminki, E; Rasimus, A; Forssas, E

    1997-12-01

    The purpose of this paper was to describe the transition of sterilization in Finland from an eugenic tool to a contraceptive. Historical data were drawn from earlier reports in Finnish. Numbers of and reasons for sterilizations since 1950 were collected from nationwide sterilization statistics. Prevalence, characteristics of sterilized women, and women's satisfaction with sterilizations were studied from a 1994 nationwide survey (74% response rate). Logistic regression was used for adjustments. In the first half of the 20th century, eugenic ideology had influence in Finland as in other parts of Europe, and the 1935 and 1950 sterilization laws had an eugenic spirit. Regardless of this, the numbers of eugenic sterilizations remained low, and in practice, family planning was the main reason for sterilization. Nonetheless, prior to 1970 not all sterilizations were freely chosen, because sterilizations were sometimes used as a precondition for abortion. Female sterilizations showed remarkable fluctuation over time. Male sterilizations have been rare. The reasons stipulated by the law did not explain the numbers of sterilizations. In a 1994 survey, 9% of Finnish women reported they were using sterilization as their current contraceptive method (n = 189). Compared to women using other contraceptive methods, sterilized women were older, had had more births and pregnancies, and came from lower social classes. Sterilized women were satisfied with their sterilization, but there were women (8.5%) who regretted it. In conclusion, sterilizations have been and are likely to continue to be an important family planning method in Finland. The extreme gender ratio suggests a need for promoting male sterilizations, and women's expressed regrets suggest consideration of a higher age limit.

  20. Toward Higher QA: From Parametric Release of Sterile Parenteral Products to PAT for Other Pharmaceutical Dosage Forms.

    PubMed

    Hock, Sia Chong; Constance, Neo Xue Rui; Wah, Chan Lai

    2012-01-01

    Pharmaceutical products are generally subjected to end-product batch testing as a means of quality control. Due to the inherent limitations of conventional batch testing, this is not the most ideal approach for determining the pharmaceutical quality of the finished dosage form. In the case of terminally sterilized parenteral products, the limitations of conventional batch testing have been successfully addressed with the application of parametric release (the release of a product based on control of process parameters instead of batch sterility testing at the end of the manufacturing process). Consequently, there has been an increasing interest in applying parametric release to other pharmaceutical dosage forms, beyond terminally sterilized parenteral products. For parametric release to be possible, manufacturers must be capable of designing quality into the product, monitoring the manufacturing processes, and controlling the quality of intermediates and finished products in real-time. Process analytical technology (PAT) has been thought to be capable of contributing to these prerequisites. It is believed that the appropriate use of PAT tools can eventually lead to the possibility of real-time release of other pharmaceutical dosage forms, by-passing the need for end-product batch testing. Hence, this literature review attempts to present the basic principles of PAT, introduce the various PAT tools that are currently available, present their recent applications to pharmaceutical processing, and explain the potential benefits that PAT can bring to conventional ways of processing and quality assurance of pharmaceutical products. Last but not least, current regulations governing the use of PAT and the manufacturing challenges associated with PAT implementation are also discussed. Pharmaceutical products are generally subjected to end-product batch testing as a means of quality control. Due to the inherent limitations of conventional batch testing, this is not the most ideal approach. In the case of terminally sterilized parenteral products, these limitations have been successfully addressed with the application of parametric release (the release of a product based on control of process parameters instead of batch sterility testing at the end of the manufacturing process). Consequently, there has been an increasing interest in applying parametric release to other pharmaceutical dosage forms. With the advancement of process analytical technology (PAT), it is possible to monitor the manufacturing processes closely. This will eventually enable quality control of the intermediates and finished products, and thus their release in real-time. Hence, this literature review attempts to present the basic principles of PAT, introduce the various PAT tools that are currently available, present their recent applications to pharmaceutical processing, and explain the potential benefits that PAT can bring to conventional ways of processing and quality assurance of pharmaceutical products. It will also discuss the current regulations governing the use of PAT and the manufacturing challenges associated with the implementation of PAT.

  1. New disinfection and sterilization methods.

    PubMed Central

    Rutala, W. A.; Weber, D. J.

    2001-01-01

    New disinfection methods include a persistent antimicrobial coating that can be applied to inanimate and animate objects (Surfacine), a high-level disinfectant with reduced exposure time (ortho-phthalaldehyde), and an antimicrobial agent that can be applied to animate and inanimate objects (superoxidized water). New sterilization methods include a chemical sterilization process for endoscopes that integrates cleaning (Endoclens), a rapid (4-hour) readout biological indicator for ethylene oxide sterilization (Attest), and a hydrogen peroxide plasma sterilizer that has a shorter cycle time and improved efficacy (Sterrad 50). PMID:11294738

  2. Enhancing Patient Safety through the Use of a Pharmaceutical Glass Designed To Prevent Cracked Containers.

    PubMed

    Schaut, Robert A; Hoff, Kyle C; Demartino, Steven E; Denson, William K; Verkleeren, Ronald L

    2017-01-01

    An essential role of packaging material for the storage and delivery of drug products is to provide adequate protection against contamination and loss of sterility. This is especially important for parenteral containers, as lack of sterility or contamination can result in serious adverse events including death. Nonetheless, cracked parenteral containers are an important source of container integrity failures for injectable drugs and pose a serious risk for patients. Despite significant investments in inspection technology, each year many injectable drugs are investigated and recalled for sterility risks associated with cracked borosilicate containers. Multiple studies and the many difficulties in detection of cracked containers suggest that the magnitude of the public health risk is even larger than the recall rate would suggest. Here we show that the root cause of cracked parenteral containers (low internal energy following annealing) is inherent to the glasses currently used for primary packaging of the majority of injectable drugs. We also describe a strengthened aluminosilicate glass that has been designed to prevent cracks in parenteral containers through the use of an engineered stress profile in the glass. Laboratory tests that simulate common filling line damage events show that the strengthened aluminosilicate glass is highly effective at preventing cracks. Significant safety benefits have been demonstrated in other industries from the use of special stress profiles in glass components to mitigate failure modes that may result in harm to humans. Those examples combined with the results described here suggest that a significant improvement in patient safety can be achieved through the use of strengthened aluminosilicate glass for parenteral containers. LAY ABSTRACT: Cracks are small cuts or gaps in a container which provide a pathway for liquid, gas, or microbes through a glass container. When these defects are introduced to conventional glass containers holding injectable medicines, the affected drug can pose serious risks to the patient receiving that medication. Specifically, the drug product may become less effective or even non-sterile, which could lead to bloodstream infections and, in some cases, death. This article presents a review of some previously documented cases of cracked glass containers that led to patient infections and deaths. Following a survey of common crack locations in glass vials, lab-based methods for replicating these cracks are presented. These methods are then used to compare the fracture response of vials made from conventional borosilicate glass and strengthened aluminosilicate glass. The results show that stable cracks are essentially prevented (at least 31 times less likely to occur) in the strengthened aluminosilicate glass containers (relative to conventional borosilicate glass). This improvement in safety is similar to improvements already engineered into other glass product designs by utilizing stored strain energy to mitigate certain failure modes. © PDA, Inc. 2017.

  3. Standardized Method for High-throughput Sterilization of Arabidopsis Seeds.

    PubMed

    Lindsey, Benson E; Rivero, Luz; Calhoun, Chistopher S; Grotewold, Erich; Brkljacic, Jelena

    2017-10-17

    Arabidopsis thaliana (Arabidopsis) seedlings often need to be grown on sterile media. This requires prior seed sterilization to prevent the growth of microbial contaminants present on the seed surface. Currently, Arabidopsis seeds are sterilized using two distinct sterilization techniques in conditions that differ slightly between labs and have not been standardized, often resulting in only partially effective sterilization or in excessive seed mortality. Most of these methods are also not easily scalable to a large number of seed lines of diverse genotypes. As technologies for high-throughput analysis of Arabidopsis continue to proliferate, standardized techniques for sterilizing large numbers of seeds of different genotypes are becoming essential for conducting these types of experiments. The response of a number of Arabidopsis lines to two different sterilization techniques was evaluated based on seed germination rate and the level of seed contamination with microbes and other pathogens. The treatments included different concentrations of sterilizing agents and times of exposure, combined to determine optimal conditions for Arabidopsis seed sterilization. Optimized protocols have been developed for two different sterilization methods: bleach (liquid-phase) and chlorine (Cl2) gas (vapor-phase), both resulting in high seed germination rates and minimal microbial contamination. The utility of these protocols was illustrated through the testing of both wild type and mutant seeds with a range of germination potentials. Our results show that seeds can be effectively sterilized using either method without excessive seed mortality, although detrimental effects of sterilization were observed for seeds with lower than optimal germination potential. In addition, an equation was developed to enable researchers to apply the standardized chlorine gas sterilization conditions to airtight containers of different sizes. The protocols described here allow easy, efficient, and inexpensive seed sterilization for a large number of Arabidopsis lines.

  4. Standardized Method for High-throughput Sterilization of Arabidopsis Seeds

    PubMed Central

    Calhoun, Chistopher S.; Grotewold, Erich; Brkljacic, Jelena

    2017-01-01

    Arabidopsis thaliana (Arabidopsis) seedlings often need to be grown on sterile media. This requires prior seed sterilization to prevent the growth of microbial contaminants present on the seed surface. Currently, Arabidopsis seeds are sterilized using two distinct sterilization techniques in conditions that differ slightly between labs and have not been standardized, often resulting in only partially effective sterilization or in excessive seed mortality. Most of these methods are also not easily scalable to a large number of seed lines of diverse genotypes. As technologies for high-throughput analysis of Arabidopsis continue to proliferate, standardized techniques for sterilizing large numbers of seeds of different genotypes are becoming essential for conducting these types of experiments. The response of a number of Arabidopsis lines to two different sterilization techniques was evaluated based on seed germination rate and the level of seed contamination with microbes and other pathogens. The treatments included different concentrations of sterilizing agents and times of exposure, combined to determine optimal conditions for Arabidopsis seed sterilization. Optimized protocols have been developed for two different sterilization methods: bleach (liquid-phase) and chlorine (Cl2) gas (vapor-phase), both resulting in high seed germination rates and minimal microbial contamination. The utility of these protocols was illustrated through the testing of both wild type and mutant seeds with a range of germination potentials. Our results show that seeds can be effectively sterilized using either method without excessive seed mortality, although detrimental effects of sterilization were observed for seeds with lower than optimal germination potential. In addition, an equation was developed to enable researchers to apply the standardized chlorine gas sterilization conditions to airtight containers of different sizes. The protocols described here allow easy, efficient, and inexpensive seed sterilization for a large number of Arabidopsis lines. PMID:29155739

  5. Comparison of Candida Albicans Adherence to Conventional Acrylic Denture Base Materials and Injection Molding Acrylic Materials.

    PubMed

    Aslanimehr, Masoomeh; Rezvani, Shirin; Mahmoudi, Ali; Moosavi, Najmeh

    2017-03-01

    Candida species are believed to play an important role in initiation and progression of denture stomatitis. The type of the denture material also influences the adhesion of candida and development of stomatitis. The aim of this study was comparing the adherence of candida albicans to the conventional and injection molding acrylic denture base materials. Twenty injection molding and 20 conventional pressure pack acrylic discs (10×10×2 mm) were prepared according to their manufacturer's instructions. Immediately before the study, samples were placed in sterile water for 3 days to remove residual monomers. The samples were then sterilized using an ultraviolet light unit for 10 minutes. 1×10 8 Cfu/ml suspension of candida albicans ATCC-10231 was prepared from 48 h cultured organism on sabouraud dextrose agar plates incubated at 37oC. 100 μL of this suspension was placed on the surface of each disk. After being incubated at 37oC for 1 hour, the samples were washed with normal saline to remove non-adherent cells. Attached cells were counted using the colony count method after shaking at 3000 rmp for 20 seconds. Finally, each group was tested for 108 times and the data were statistically analyzed by t-test. Quantitative analysis revealed that differences in colony count average of candida albicans adherence to conventional acrylic materials (8.3×10 3 ) comparing to injection molding acrylic resins (6×10 3 ) were statistically significant ( p <0.001). Significant reduction of candida albicans adherence to the injection acrylic resin materials makes them valuable for patients with high risk of denture stomatitis.

  6. Evaluation of conventional therapeutic methods versus maggot therapy in the evolution of healing of tegumental injuries in Wistar rats with and without diabetes mellitus.

    PubMed

    Masiero, Franciéle Souza; Thyssen, Patricia Jacqueline

    2016-06-01

    Larval therapy consists on the application of sterilized carrion flies larvae, reared in laboratory, on acute, chronic, and/or infected wounds in order to promote healing. Conventional methods for treating injuries include mechanical debridement or silver-based dressings; however, they are not always effective for wound healing. Larval therapy is a feasible and safe treatment for therapeutic application and, in many cases, the only and the most recommended alternative for difficult healing injuries. Thus, this study aimed to evaluate the competence of Cochliomyia macellaria F. (Diptera: Calliphoridae) as a suitable species for therapeutic application and evaluate time and effectiveness of the types of treatments most commonly used to treat integumental injuries. C. macellaria eggs were obtained from colonies established in laboratory and sterilized prior to application. Twenty-five larvae were applied for each centimeter squared of lesion. Lesions were induced in 24 Wistar rats; type 1 diabetes mellitus was induced in 12 of them. Animals were divided in four groups with three individuals each, being denominated: larval therapy, larval therapy associated with foam dressing with silver release, mechanical debridement with foam dressing silver and control group, without treatment. All treatments were applied once and held for 24 h. Medical application of larvae was found to be safe, as only dead tissue was removed, and efficient to accelerate healing process when compared to other treatments.

  7. Committee Opinion No. 695: Sterilization of Women: Ethical Issues and Considerations.

    PubMed

    2017-04-01

    Sterilization is the most common method of contraception among married couples, with nearly twice as many couples choosing female partner sterilization over male sterilization. Although sterilization is among the most straightforward surgical procedures an obstetrician-gynecologist performs, it is enormously complex when considered from a historical, sociological, or ethical perspective. Sterilization practices have embodied a problematic tension, in which some women who desired fertility were sterilized without their knowledge or consent, and other women who wanted sterilization to limit their family size lacked access to it. An ethical approach to the provision of sterilization must, therefore, promote access for women who wish to use sterilization as a method of contraception, but at the same time safeguard against coercive or otherwise unjust uses. This Committee Opinion reviews ethical issues related to the sterilization of women and outlines an approach to providing permanent sterilization within a reproductive justice framework that recognizes that all women have a right to pursue and to prevent pregnancy.

  8. Committee Opinion No 695 Summary: Sterilization of Women: Ethical Issues and Considerations.

    PubMed

    2017-04-01

    Sterilization is the most common method of contraception among married couples, with nearly twice as many couples choosing female partner sterilization over male sterilization. Although sterilization is among the most straightforward surgical procedures an obstetrician-gynecologist performs, it is enormously complex when considered from a historical, sociological, or ethical perspective. Sterilization practices have embodied a problematic tension, in which some women who desired fertility were sterilized without their knowledge or consent, and other women who wanted sterilization to limit their family size lacked access to it. An ethical approach to the provision of sterilization must, therefore, promote access for women who wish to use sterilization as a method of contraception, but at the same time safeguard against coercive or otherwise unjust uses. This Committee Opinion reviews ethical issues related to the sterilization of women and outlines an approach to providing permanent sterilization within a reproductive justice framework that recognizes that all women have a right to pursue and to prevent pregnancy.

  9. [Evaluation of the influence of sterilization method on the stability of carboxymethyl cellulose wound dressing].

    PubMed

    Muselík, Jan; Wojnarová, Lenka; Masteiková, Ruta; Sopuch, Tomáš

    2013-04-01

    Carboxymethyl cellulose, especially its sodium salt, is a versatile pharmaceutical excipient. From a therapeutic point of view, sodium salt of carboxymethyl cellulose is used in the production of modern wound dressings to allow moist wound healing. Wound dressings must be sterile and stable throughout their shelf life and have to be able to withstand different temperature conditions. At the present time, a number of sterilization methods are available. In the case of polymeric materials, the selected sterilization process must not induce any changes in the polymer structure, such as polymer chains cleavage, changes in cross-linking, etc. This paper evaluates the influence of different sterilization methods (γ-radiation, β-radiation, ethylene oxide) on the stability of carboxymethyl cellulose and the results of long-term and accelerated stability testing. Evaluation of samples was performed using size-exclusion chromatography. The obtained results showed that ethylene oxide sterilization was the least aggressive variant of the sterilization methods tested. When the γ-radiation sterilization was used, the changes in the size of the carboxymethyl cellulose molecule occurred. In the course of accelerated and long term stability studies, no further degradation changes were observed, and thus sterilized samples are suitable for long term storage.

  10. Human pathogens, nosocomial infections, heat-sensitive textile implants, and an innovative approach to deal with them.

    PubMed

    Cinquemani, Claudio

    2011-01-01

    Implantable polymers, as used for biomedical applications, inherently have to be sterile. Nonetheless, most implants, particularly those comprised of biomaterials developed in recent years for tissue engineering, are heat sensitive. Therefore, use of hazardous (radio)chemicals--due to lack of alternative methods--is still state of the art for sterilization processes. The drawbacks of these techniques, both drastic and well known, lead to the demand for an alternative sterilization method, which is equally obvious and urgent. High-pressure fluid treatment is a low-temperature technique that is already in use for pasteurization of liquid food products. This paper explores inactivation of vegetative microorganisms, spores, and endotoxins adherent to solid surfaces using compressed CO(2). Pressures ranging from 50 to 100 bar and temperatures from 25 °C to 50 °C were explored to investigate liquid, gaseous or supercritical state. Analysis of variance (ANOVA) and statistical modeling were used to identify the optimum parameter settings for inactivation of pathogenic bacteria and fungi (Candida albicans, Staphylococcus aureus). The addition of small amounts of ozone ensures inactivation of persistent spores (Bacillus stearothermophilus, B. subtilis) up to 10(6) cfu/ml, while endotoxins remain in practically unchanged concentration on the polymer surface. We then discuss environmental issues of the process and inactivation mechanisms. The replacement of conventional chemicals with nonpersistent ones resolves organizational and safety-related issues and protects natural resources as well as handling staff. The pressurized-fluid-based method exhibits mild treatment parameters, thus protecting sensitive textures. Finally, an outlook on possible applications of this innovative technique is presented.

  11. Sterilization processes. Meeting the demands of today's health care technology.

    PubMed

    Crow, S

    1993-09-01

    Universal Precautions dictate sterilization for all invasive equipment that break the blood barrier; however, current methods of sterilization, such as steam and ethylene oxide gas (ETO), are not compatible with many of the delicate, heat-sensitive surgical instruments used in modern health care. In addition, traditional sterilization methods are often too time consuming for practical use in the operating room. Clearly, new sterilization processes need to be developed. In this article, the criteria modern sterilization processes must meet and how some manufacturers plan to meet this challenge are discussed. In addition, the pros and cons of using peracetic acid (the newest sterilization process currently available) are examined.

  12. A reaction-diffusion model of the Darien Gap Sterile Insect Release Method

    NASA Astrophysics Data System (ADS)

    Alford, John G.

    2015-05-01

    The Sterile Insect Release Method (SIRM) is used as a biological control for invasive insect species. SIRM involves introducing large quantities of sterilized male insects into a wild population of invading insects. A fertile/sterile mating produces offspring that are not viable and the wild insect population will eventually be eradicated. A U.S. government program maintains a permanent sterile fly barrier zone in the Darien Gap between Panama and Columbia to control the screwworm fly (Cochliomyia Hominivorax), an insect that feeds off of living tissue in mammals and has devastating effects on livestock. This barrier zone is maintained by regular releases of massive quantities of sterilized male screwworm flies from aircraft. We analyze a reaction-diffusion model of the Darien Gap barrier zone. Simulations of the model equations yield two types of spatially inhomogeneous steady-state solutions representing a sterile fly barrier that does not prevent invasion and a barrier that does prevent invasion. We investigate steady-state solutions using both phase plane methods and monotone iteration methods and describe how barrier width and the sterile fly release rate affects steady-state behavior.

  13. Reliability of Laparoscopic Compared With Hysteroscopic Sterilization at One Year: A Decision Analysis

    PubMed Central

    Gariepy, Aileen M.; Creinin, Mitchell D.; Schwarz, Eleanor B.; Smith, Kenneth J.

    2011-01-01

    OBJECTIVE To estimate the probability of successful sterilization after hysteroscopic or laparoscopic sterilization procedure. METHODS An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. RESULTS In the base case analysis, the proportion of women having a successful sterilization procedure on first attempt is 99% for laparoscopic, 88% for hysteroscopic in the operating room and 87% for hysteroscopic in the office. The probability of having a successful sterilization procedure within one year is 99% with laparoscopic, 95% for hysteroscopic in the operating room, and 94% for hysteroscopic in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. CONCLUSIONS Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within one year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization. PMID:21775842

  14. Failure of non-vacuum steam sterilization processes for dental handpieces.

    PubMed

    Winter, S; Smith, A; Lappin, D; McDonagh, G; Kirk, B

    2017-12-01

    Dental handpieces are used in critical and semi-critical operative interventions. Although some dental professional bodies recommend that dental handpieces are sterilized between patient use there is a lack of clarity and understanding of the effectiveness of different steam sterilization processes. The internal mechanisms of dental handpieces contain narrow lumens (0.8-2.3 mm) which can impede the removal of air and ingress of saturated steam required to achieve sterilization conditions. To identify the extent of sterilization failure in dental handpieces using a non-vacuum process. In-vitro and in-vivo investigations were conducted on widely used UK bench-top steam sterilizers and three different types of dental handpieces. The sterilization process was monitored inside the lumens of dental handpieces using thermometric (TM; dataloggers), chemical indicator (CI), and biological indicator (BI) methods. All three methods of assessing achievement of sterility within dental handpieces that had been exposed to non-vacuum sterilization conditions demonstrated a significant number of failures [CI: 8/3024 (fails/no. of tests); BI: 15/3024; TM: 56/56] compared to vacuum sterilization conditions (CI: 2/1944; BI: 0/1944; TM: 0/36). The dental handpiece most likely to fail sterilization in the non-vacuum process was the surgical handpiece. Non-vacuum sterilizers located in general dental practice had a higher rate of sterilization failure (CI: 25/1620; BI: 32/1620; TM: 56/56) with no failures in vacuum process. Non-vacuum downward/gravity displacement, type N steam sterilizers are an unreliable method for sterilization of dental handpieces in general dental practice. The handpiece most likely to fail sterilization is the type most frequently used for surgical interventions. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  15. Factors associated with sterilization use among women leaving a U.S. jail: a mixed methods study.

    PubMed

    Ramaswamy, Megha; Kelly, Patricia J

    2014-07-31

    Despite the high rates of reported sterilization use among women who have spent time in correctional facilities, little is known about the context in which women in this population choose this option. The objective of our study was to use both quantitative and qualitative methods to understand factors associated with sterilization use among women leaving a U.S. jail. We administered a cross-sectional survey with 102 jailed women who were participating in a study about contraceptive use after release from jail, and then conducted semi-structured interviews with 29 of those women after their release from jail. We used logistic regression and analytic induction to assess factors associated with self-reported sterilization use. In our cross-sectional survey, one-third of our sample reported a history of sterilization use. Controlling for age and past pregnancies, the only factor associated with sterilization use was physical abuse history before age 16. In semi-structured interviews, we found that women's primary motivation for sterilization was the desire to limit childbearing permanently, in some cases where other contraceptive methods had failed them. The decision for sterilization was generally supported by family, partners, and providers. Many women who opted for sterilization expressed financial concern about supporting children and/or reported family histories of sterilization. The decision to use the permanent method of sterilization as a contraceptive method is a complex one. Results from this study suggest that while explicit coercion may not be a factor in women's choice for sterilization, interpersonal relationship histories, negative experiences with contraceptives, and structural constraints, such as financial concerns and ongoing criminal justice involvement, seem to influence sterilization use among the vulnerable group of women with criminal justice histories. Public health programs that connect women to reproductive health services should acknowledge constraints on contraceptive decision-making in vulnerable populations.

  16. Effect of repeated sterilization by different methods on strength of carbon fiber rods used in external fixator systems.

    PubMed

    Unal, Omer Kays; Poyanli, Oguz Sukru; Unal, Ulku Sur; Mutlu, Hasan Huseyin; Ozkut, Afsar Timucin; Esenkaya, Irfan

    2018-05-16

    We set out to reveal the effects of repeated sterilization, using different methods, on the carbon fiber rods of external fixator systems. We used a randomized set of forty-four unused, unsterilized, and identical carbon fiber rods (11 × 200 mm), randomly assigned to two groups: unsterilized (US) (4 rods) and sterilized (40 rods). The sterilized rods were divided into two groups, those sterilized in an autoclave (AC) and by hydrogen peroxide (HP). These were further divided into five subgroups based on the number of sterilization repetition to which the fibers were subjected (25-50-75-100-200). A bending test was conducted to measure the maximum bending force (MBF), maximum deflection (MD), flexural strength (FS), maximum bending moment (MBM) and bending rigidity (BR). We also measured the surface roughness of the rods. An increase in the number of sterilization repetition led to a decrease in MBF, MBM, FS, BR, but increased MD and surface roughness (p < 0.01). The effect of the number of sterilization repetition was more prominent in the HP group. This study revealed that the sterilization method and number of sterilization repetition influence the strength of the carbon fiber rods. Increasing the number of sterilization repetition degrades the strength and roughness of the rods.

  17. Effect of three ophthalmic solutions on chemical conjunctivitis in the neonate.

    PubMed

    Yasunaga, S

    1977-02-01

    In an attempt to reduce chemical conjunctivitis after silver nitrate prophylaxis, three different ophthalmic solutions (sodium chloride, sterile water, and a boric acid-sodium borate solution) were used to irrigate the eyes immediately after prophylaxis in 450 neonates. Sterile water significantly reduced (P less than .02) the prevalence of chemical conjunctivitis when compared to the conventional sodium chloride rinse. A significantly greater prevalence of chemical irritation in low-birth-weight infants was also noted (P less than .02).

  18. A Model Framework to Estimate Impact and Cost of Genetics-Based Sterile Insect Methods for Dengue Vector Control

    PubMed Central

    Alphey, Nina; Alphey, Luke; Bonsall, Michael B.

    2011-01-01

    Vector-borne diseases impose enormous health and economic burdens and additional methods to control vector populations are clearly needed. The Sterile Insect Technique (SIT) has been successful against agricultural pests, but is not in large-scale use for suppressing or eliminating mosquito populations. Genetic RIDL technology (Release of Insects carrying a Dominant Lethal) is a proposed modification that involves releasing insects that are homozygous for a repressible dominant lethal genetic construct rather than being sterilized by irradiation, and could potentially overcome some technical difficulties with the conventional SIT technology. Using the arboviral disease dengue as an example, we combine vector population dynamics and epidemiological models to explore the effect of a program of RIDL releases on disease transmission. We use these to derive a preliminary estimate of the potential cost-effectiveness of vector control by applying estimates of the costs of SIT. We predict that this genetic control strategy could eliminate dengue rapidly from a human community, and at lower expense (approximately US$ 2∼30 per case averted) than the direct and indirect costs of disease (mean US$ 86–190 per case of dengue). The theoretical framework has wider potential use; by appropriately adapting or replacing each component of the framework (entomological, epidemiological, vector control bio-economics and health economics), it could be applied to other vector-borne diseases or vector control strategies and extended to include other health interventions. PMID:21998654

  19. Evaluation of user input methods for manipulating a tablet personal computer in sterile techniques.

    PubMed

    Yamada, Akira; Komatsu, Daisuke; Suzuki, Takeshi; Kurozumi, Masahiro; Fujinaga, Yasunari; Ueda, Kazuhiko; Kadoya, Masumi

    2017-02-01

    To determine a quick and accurate user input method for manipulating tablet personal computers (PCs) in sterile techniques. We evaluated three different manipulation methods, (1) Computer mouse and sterile system drape, (2) Fingers and sterile system drape, and (3) Digitizer stylus and sterile ultrasound probe cover with a pinhole, in terms of the central processing unit (CPU) performance, manipulation performance, and contactlessness. A significant decrease in CPU score ([Formula: see text]) and an increase in CPU temperature ([Formula: see text]) were observed when a system drape was used. The respective mean times taken to select a target image from an image series (ST) and the mean times for measuring points on an image (MT) were [Formula: see text] and [Formula: see text] s for the computer mouse method, [Formula: see text] and [Formula: see text] s for the finger method, and [Formula: see text] and [Formula: see text] s for the digitizer stylus method, respectively. The ST for the finger method was significantly longer than for the digitizer stylus method ([Formula: see text]). The MT for the computer mouse method was significantly longer than for the digitizer stylus method ([Formula: see text]). The mean success rate for measuring points on an image was significantly lower for the finger method when the diameter of the target was equal to or smaller than 8 mm than for the other methods. No significant difference in the adenosine triphosphate amount at the surface of the tablet PC was observed before, during, or after manipulation via the digitizer stylus method while wearing starch-powdered sterile gloves ([Formula: see text]). Quick and accurate manipulation of tablet PCs in sterile techniques without CPU load is feasible using a digitizer stylus and sterile ultrasound probe cover with a pinhole.

  20. Sterility and Safety Validation for Transport Packaging of Organs and Tissues.

    PubMed

    Cobos, M; Trunzo, L; Vogt, M V; Romero, O; Anessi, C; Pachado, J; Ciávaro, M N; Horak, C; Bacqué, M C

    2018-03-01

    The bags used in the transport of organs and tissues must be sterile, nontoxic, pyrogen free, and must serve as a barrier throughout their useful life. The goal of this study was to show the sterility, safety, and functionality of the bags subjected to irradiation, through validated procedures and techniques. The selected sterilization method was the use of gamma radiation. The sterilization dose was determined based on validated standards for the sterilization of medical products, ISO 11137-2: 2013 and ISO/TS 13004: 2013, using the Verification Dose Maximum method on samples belonging to 3 manufacturing lots. The ISO 10993-5: 2009 standard was used in the cytotoxicity tests, by means of extracts test and quantitative technique of MTT, 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide. The tests to determine the expiration date of the kit were performed by ASTM F1980, accelerated aging, and ASTM D3078 to evaluate hermeticity. The irradiation dose validated to reach the required sterility safety level was 22.5 kGy. The constituent materials and the sterilization method do not generated cellular toxicity, and the product was not modified during the simulated time of 5 years. Sterilization by irradiation is a method that leaves no residue, does not harm the properties of the material because it is conducted in cold, and as the sterilizing agent, the energy absorbed by the product is highly penetrating and can be treated in its final packaging, with no risk of postcontamination. It is for this reason that it is prioritized over other methods of sterilization. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Sterile neutrinos and flavor ratios in IceCube

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brdar, Vedran; Kopp, Joachim; Wang, Xiao-Ping, E-mail: vbrdar@uni-mainz.de, E-mail: jkopp@uni-mainz.de, E-mail: xiaowang@uni-mainz.de

    2017-01-01

    The flavor composition of astrophysical neutrinos observed in neutrino telescopes is a powerful discriminator between different astrophysical neutrino production mechanisms and can also teach us about the particle physics properties of neutrinos. In this paper, we investigate how the possible existence of light sterile neutrinos can affect these flavor ratios. We consider two scenarios: (i) neutrino production in conventional astrophysical sources, followed by partial oscillation into sterile states; (ii) neutrinos from dark matter decay with a primary flavor composition enhanced in tau neutrinos or sterile neutrinos. Throughout the paper, we constrain the sterile neutrino mixing parameters from a full globalmore » fit to short and long baseline data. We present our results in the form of flavor triangles and, for scenario (ii), as exclusion limits on the dark matter mass and lifetime, derived from a fit to IceCube high energy starting events and through-going muons. We argue that identifying a possible flux of neutrinos from dark matter decay may require analyzing the flavor composition as a function of neutrino energy.« less

  2. History of sterile compounding in U.S. hospitals: learning from the tragic lessons of the past.

    PubMed

    Myers, Charles E

    2013-08-15

    The evolution of sterile compounding in the context of hospital patient care, the evolution of related technology, past incidents of morbidity and mortality associated with preparations compounded in various settings, and efforts over the years to improve compounding practices are reviewed. Tightened United States Pharmacopeial Convention standards (since 2004) for sterile compounding made it difficult for hospitals to achieve all of the sterile compounding necessary for patient care. Shortages of manufactured injections added to the need for compounding. Non-hospital-based compounding pharmacies increased sterile compounding to meet the needs. Gaps in federal and state laws and regulations about compounding pharmacies led to deficiencies in their regulation. Lapses in sterility led to injuries and deaths. Perspectives offered include potential actions, including changes in practitioner education, better surveillance of sterile compounding, regulatory reforms, reexamination of the causes of drug shortages, and the development of new technologies. Over the years, there have been numerous exhortations for voluntary better performance in sterile compounding. In addition, professional leadership has been vigorous and extensive in the form of guidance, publications, education, enforceable standards, and development of various associations and organizations dealing with safe compounding practices. Yet problems continue to occur. We must engage in diligent learning from the injuries and tragedies that have occurred. Assuming that we are already doing all we can to avoid problems would be an abdication of the professional mission of pharmacists. It would be wrong thinking to assume that the recent problems in large-scale compounding pharmacies are the only problems that warrant attention. It is time for a systematic assessment of the nature and the dimensions of the problems in every type of setting where sterile compounding occurs. It also is time for some innovative thinking about ensuring safety in sterile compounding.

  3. Dominance of Sterilization and Alternative Choices of Contraception in India: An Appraisal of the Socioeconomic Impact

    PubMed Central

    de Oliveira, Isabel Tiago; Dias, José G.; Padmadas, Sabu S.

    2014-01-01

    Background The recent decline in fertility in India has been unprecedented especially in southern India, where fertility is almost exclusively controlled by means of permanent contraceptive methods, mainly female sterilization, which constitutes about two-thirds of overall contraceptive use. Many Indian women undergo sterilization at relatively young ages as a consequence of early marriage and childbearing in short birth intervals. This research aims to investigate the socioeconomic factors determining the choices for alternative contraceptive choices against the dominant preference for sterilization among married women in India. Methods Data for this study are drawn from the 2005–06 National Family Health Surveys focusing on a sample of married women who reported having used a method of contraception in the five years preceding the survey. A multilevel multinomial logit regression is used to estimate the impact of socioeconomic factors on contraceptive choices, differentiating temporary modern or traditional methods versus sterilization. Findings Religious affiliation, women's education and occupation had overarching influence on method choices amongst recent users. Muslim women were at higher odds of choosing a traditional or modern temporary method than sterilization. Higher level of women's education increased the odds of modern temporary method choices but the education effect on traditional method choices was only marginally significant. Recent users belonging to wealthier households had higher odds of choosing modern methods over sterilization. Exposure to family planning messages through radio had a positive effect on modern and traditional method choices. Community variations in method choices were highly significant. Conclusion The persistent dominance of sterilization in the Indian family planning programme is largely determined by socioeconomic conditions. Reproductive health programmes should address the socioeconomic barriers and consider multiple cost-effective strategies such as mass media to promote awareness of modern temporary methods. PMID:24489759

  4. Quarter of a century of female sterilization in Jos, Central Nigeria.

    PubMed

    Mutihir, Josiah T; Nyango, D D

    2011-03-01

    The study was to assess the types and trend of female sterilization between January 1985 and December 2009 (25 years) in Jos, Central Nigeria. There were 25,313 new acceptors of modern contraceptive methods out of which 4,951 (19.6%) were female sterilizations. Minilaparotomy was the commonest method of female sterilization. Local anaesthesia was the commonest anaesthetic utilized. The women were mostly women of relatively older age, grandmultiparous and with large family size. The women were of mean of 38.4 years, and 60% had more than 5 children at the time of sterilization. Interval sterilization constituted 78.5% of the female sterilizations. The acceptance of female sterilization, however, has declined over the years, as acceptance of the long acting contraceptive implants increases. Female sterilization by minilaparotomy under local anaesthesia was found to be feasible, cost effective and acceptable by majority of clients, and recommended for integration into minor gynaecological procedures in our institutions.

  5. [Sterilization and eugenics].

    PubMed

    Shasha, Shaul M

    2011-04-01

    The term "eugenics" was coined by Francis Galton in 1883 and was defined as the science of the improvement of the human race by better breeding. "Positive eugenics" referred to methods of encouraging the "most fit" to reproduce more often, while "negative eugenics" was related to ways of discouraging or preventing the "less fit" from reproducing by birth control and sterilization. Many western countries adopted eugenics programs including Britain, Canada, Norway, Australia, Switzerland and others. In Sweden more then 62,000 "unfits" were forcibly sterilized. Many states in the U.S.A. had adopted marriage laws with eugenics criteria including forced sterilization. Approximately 64,000 individuals were sterilized. Eugenics considerations also lay behind the adoption of the Immigration Restriction Act of 1924. The Largest plan on eugenics was adopted by the Nazi regime in Germany. Hundreds of thousands of people, who were viewed as being "unfit", were forcibly sterilized by different methods: Surgical sterilization or castration with severe complications and high mortality rates. X-ray irradiation. The method was suggested by Brack, and tested by Schuman using prisoners in Block No. 10 in Auschwitz and Birkenau. Experiments were also performed by Brack on prisoners using the "window method". "Klauberg method"--injection of irritating materials into the uterus. Experiments were conducted using the plant Caladium Seguinum which was believed to have sterilization and castration properties.

  6. Effects of supercritical carbon dioxide sterilization on polysaccharidic membranes for surgical applications.

    PubMed

    Scognamiglio, F; Blanchy, M; Borgogna, M; Travan, A; Donati, I; Bosmans, J W A M; Foulc, M P; Bouvy, N D; Paoletti, S; Marsich, E

    2017-10-01

    Sterilization methods such as ɣ-irradiation, steam sterilization and ethylene oxide gas treatment can have negative effects on molecular structure and properties of polysaccharide-based biomaterials. In this perspective, the use of supercritical carbon dioxide (scCO 2 ) has been proposed as an alternative method for biomaterial sterilization. In this work, chemical, mechanical and biological properties of polysaccharidic membranes for surgical applications were investigated after sterilization by scCO 2 . Four sets of sterilizing conditions were considered and SEC analyses were performed in order to identify the one with lower impact on the polysaccharidic matrix of membranes (alginate). Mechanical tests showed that the resistance of membranes was slightly affected after sterilization. Biological analyses proved the biocompatibility of the sterilized membranes both in vitro and in a preliminary in vivo test. Overall, this study points out that this sterilization technique can be successfully employed to achieve an effective and safe sterilization of polysaccharidic membranes for surgical use. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Sterilization of microorganisms by the supercritical carbon dioxide micro-bubble method.

    PubMed

    Ishikawa, H; Shimoda, M; Shiratsuchi, H; Osajima, Y

    1995-10-01

    Lactobacillus brevis and Saccharomyces cerevisiae were completely sterilized by the supercritical (SC) CO2 micro-bubble method. Gaseous (G) and liquid (LQ) CO2 were used in a similar manner to compare the sterilizing effect. Among the three treatments, the microorganisms were only effectively sterilized by the SC CO2 treatment at 25 MPa and 35 degrees C.

  8. Ozone Gas as a Benign Sterilization Treatment for PLGA Nanofiber Scaffolds

    PubMed Central

    de Jesus Andreoli Pinto, Terezinha; Bou-Chacra, Nadia Araci; Galante, Raquel; de Araújo, Gabriel Lima Barros; do Nascimento Pedrosa, Tatiana; Maria-Engler, Silvya Stuchi

    2016-01-01

    The use of electrospun nanofibers for tissue engineering and regenerative medicine applications is a growing trend as they provide improved support for cell proliferation and survival due, in part, to their morphology mimicking that of the extracellular matrix. Sterilization is a critical step in the fabrication process of implantable biomaterial scaffolds for clinical use, but many of the existing methods used to date can negatively affect scaffold properties and performance. Poly(lactic-co-glycolic acid) (PLGA) has been widely used as a biodegradable polymer for 3D scaffolds and can be significantly affected by current sterilization techniques. The aim of this study was to investigate pulsed ozone gas as an alternative method for sterilizing PLGA nanofibers. The morphology, mechanical properties, physicochemical properties, and response of cells to PLGA nanofiber scaffolds were assessed following different degrees of ozone gas sterilization. This treatment killed Geobacillus stearothermophilus spores, the most common biological indicator used for validation of sterilization processes. In addition, the method preserved all of the characteristics of nonsterilized PLGA nanofibers at all degrees of sterilization tested. These findings suggest that ozone gas can be applied as an alternative method for sterilizing electrospun PLGA nanofiber scaffolds without detrimental effects. PMID:26757850

  9. Ozone Gas as a Benign Sterilization Treatment for PLGA Nanofiber Scaffolds.

    PubMed

    Rediguieri, Carolina Fracalossi; Pinto, Terezinha de Jesus Andreoli; Bou-Chacra, Nadia Araci; Galante, Raquel; de Araújo, Gabriel Lima Barros; Pedrosa, Tatiana do Nascimento; Maria-Engler, Silvya Stuchi; De Bank, Paul A

    2016-04-01

    The use of electrospun nanofibers for tissue engineering and regenerative medicine applications is a growing trend as they provide improved support for cell proliferation and survival due, in part, to their morphology mimicking that of the extracellular matrix. Sterilization is a critical step in the fabrication process of implantable biomaterial scaffolds for clinical use, but many of the existing methods used to date can negatively affect scaffold properties and performance. Poly(lactic-co-glycolic acid) (PLGA) has been widely used as a biodegradable polymer for 3D scaffolds and can be significantly affected by current sterilization techniques. The aim of this study was to investigate pulsed ozone gas as an alternative method for sterilizing PLGA nanofibers. The morphology, mechanical properties, physicochemical properties, and response of cells to PLGA nanofiber scaffolds were assessed following different degrees of ozone gas sterilization. This treatment killed Geobacillus stearothermophilus spores, the most common biological indicator used for validation of sterilization processes. In addition, the method preserved all of the characteristics of nonsterilized PLGA nanofibers at all degrees of sterilization tested. These findings suggest that ozone gas can be applied as an alternative method for sterilizing electrospun PLGA nanofiber scaffolds without detrimental effects.

  10. Dominance of sterilization and alternative choices of contraception in India: an appraisal of the socioeconomic impact.

    PubMed

    de Oliveira, Isabel Tiago; Dias, José G; Padmadas, Sabu S

    2014-01-01

    The recent decline in fertility in India has been unprecedented especially in southern India, where fertility is almost exclusively controlled by means of permanent contraceptive methods, mainly female sterilization, which constitutes about two-thirds of overall contraceptive use. Many Indian women undergo sterilization at relatively young ages as a consequence of early marriage and childbearing in short birth intervals. This research aims to investigate the socioeconomic factors determining the choices for alternative contraceptive choices against the dominant preference for sterilization among married women in India. Data for this study are drawn from the 2005-06 National Family Health Surveys focusing on a sample of married women who reported having used a method of contraception in the five years preceding the survey. A multilevel multinomial logit regression is used to estimate the impact of socioeconomic factors on contraceptive choices, differentiating temporary modern or traditional methods versus sterilization. Religious affiliation, women's education and occupation had overarching influence on method choices amongst recent users. Muslim women were at higher odds of choosing a traditional or modern temporary method than sterilization. Higher level of women's education increased the odds of modern temporary method choices but the education effect on traditional method choices was only marginally significant. Recent users belonging to wealthier households had higher odds of choosing modern methods over sterilization. Exposure to family planning messages through radio had a positive effect on modern and traditional method choices. Community variations in method choices were highly significant. The persistent dominance of sterilization in the Indian family planning programme is largely determined by socioeconomic conditions. Reproductive health programmes should address the socioeconomic barriers and consider multiple cost-effective strategies such as mass media to promote awareness of modern temporary methods.

  11. Spacecraft sterilization.

    NASA Technical Reports Server (NTRS)

    Kalfayan, S. H.

    1972-01-01

    Spacecraft sterilization is a vital factor in projects for the successful biological exploration of other planets. The microorganisms of major concern are the fungi and bacteria. Sterilization procedures are oriented toward the destruction of bacterial spores. Gaseous sterilants are examined, giving attention to formaldehyde, beta-propiolactone, ethylene oxide, and the chemistry of the bactericidal action of sterilants. Radiation has been seriously considered as another method for spacecraft sterilization. Dry heat sterilization is discussed together with the effects of ethylene oxide decontamination and dry heat sterilization on materials.

  12. Which is the best method of sterilization of tumour bone for reimplantation? a biomechanical and histopathological study

    PubMed Central

    2010-01-01

    Introduction Sterilization and re-usage of tumour bone for reconstruction after tumour resection is now gaining popularity in the East. This recycle tumour bone needs to be sterilized in order to eradicate the tumour cells before re-implantation for limb salvage procedures. The effect of some of these treatments on the integrity and sterility of the bone after treatment has been published but there has yet been a direct comparison between the various methods of sterilization to determine the one method that gives the best tumour kill without compromising the bone's structural integrity. Method This study was performed to evaluate the effect of several sterilization methods on the mechanical behavior of human cortical bone graft and histopathology evaluation of tumour bone samples after being processed with 4 different methods of sterilization. Fresh human cortical tumour bone is harvested from the diaphyseal region of the tumour bone were sterilized by autoclave (n =10); boiling (n =10); pasteurization (n =10); and irradiation (n =10). There were also 10 control specimens that did not receive any form of sterilization treatment. The biomechanical test conducted were stress to failure, modulus and strain to failure, which were determined from axial compression testing. Statistical analysis (ANOVA) was performed on these results. Significance level (α) and power (β) were set to 0.05 and 0.90, respectively. Results ANOVA analysis of 'failure stress', 'modulus' and 'strain to failure' demonstrated significant differences (p < 0.05) between treated cortical bone and untreated specimens under mechanical loading. 'Stress to failure' was significantly reduced in boiled, autoclaved and irradiated cortical bone samples (p < 0.05). 'Modulus' detected significant differences in the boiled, autoclaved and pasteurization specimens compared to controls (p < 0.05). 'Strain to failure' was reduced by irradiation (p < 0.05) but not by the other three methods of treatments. Histopathology study revealed no viable tumour cell in any of four types of treatment group compared to the untreated control group. Conclusions Sterilization of cortical bone sample by pasteurization and to a lesser extent, irradiation does not significantly alter the mechanical properties when compared with untreated samples. Mechanical properties degrade with the use of high temperature for sterilization (boiling). All methods of sterilization gave rise to 100 percent tumour kill. PMID:20831801

  13. Attitude toward, acceptance of and knowledge about female sterilization as a method of contraception.

    PubMed

    Erlenwein, J; Kundu, S; Schippert, C; Soergel, P; Hillemanns, P; Staboulidou, I

    2015-02-01

    Surgical sterilization via tubal ligation or the disconnection of the tubes is a method of permanent contraception. The aim of this study was to evaluate the attitude, acceptance and knowledge of women about female sterilization as a method of contraception in terms of the social and cultural backgrounds of those women. Prospective study based on an anonymous questionnaire that analyzed background knowledge, attitude, influence factors and motivation regarding sterilization, as well as the reasons for declining. The questionnaire also attempted to evaluate the effects on the self-esteem of the women, as well as the impact of religious dogma and the related beliefs. One thousand, eight hundred questionnaires were distributed, and 1247 women completed the questionnaire—a response rate of 69.3%. There were mainly positive attitudes toward sterilization as a contraceptive method. Cultural background, including religion and faith; the mother's experiences and point of view; knowledge; family planning and the actual life situation have an influence on the attitudes toward and acceptance of sterilization as a contraceptive method and on the final choice of a contraceptive method. Cultural background and present life situation have a great impact on the attitude toward and acceptance of sterilization as a method of contraception, thus influencing the final choice of a contraceptive method. Detailed counselling about this topic is essential and should be improved. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. Review and state of the art on radiation sterilization of medical devices

    NASA Astrophysics Data System (ADS)

    Dorpema, J. W.

    Review and state of art of radiation sterilization Radiation as a sterilization method was designed in the years 1950-1960. The decade afterwards the application for sterilization of medical products and devices was developped. Extensive studies performed on both the physical, chemical and (micro) biological aspects revealed the requirements for safety and efficacy. These efforts were highly stimulated by the IAEA and resulted in a elegant sterilization method. In product manufacturing, where sterilization represents a final step in the production sequence, radiation has eversince reached its widest application in the field of medical devices. As a spin off it initiated new ideas and approaches towards sterilization in general. Consequently sterility was redefined in terms of a probabilistic concept (10-6) and the bioburden determination method was introduced as a tool for both quality control and potential instrument for dose setting. However these refinements also created controversies, whereby the dose requirements became divided for Europe and North America. Moreover studies recently performed in Europe suggest even a further extension of this opinion gap. Detailed studies, on the clinical effects of low dose treated products (12.5 - 17.5 kGy) are needed to counterbalance the dose suggestions extracted from statistically based dose determinations (> 28 kGy ) and the microbiological resistance determinations ( > 28 - 30 kGy). Dose setting based on risk classification could be considered for distinct product categories. In the mean time a general acceptance of the originally, in the early seventhies, established minimum dose of 25 kGy would seem a reasonable compromise. As the interest for radiation sterilization as the favourable, non polluting and simple method is increasing rapidly over the last five years, both gamma- and beta driven sterilization plants will be needed. Harmonization on sterilization dose therfore requires high priority.

  15. Sterile Product Packaging and Delivery Systems.

    PubMed

    Akers, Michael J

    2015-01-01

    Both conventional and more advanced product container and delivery systems are the focus of this brief article. Six different product container systems will be discussed, plus advances in primary packaging for special delivery systems and needle technology.

  16. A general method for identifying major hybrid male sterility genes in Drosophila.

    PubMed

    Zeng, L W; Singh, R S

    1995-10-01

    The genes responsible for hybrid male sterility in species crosses are usually identified by introgressing chromosome segments, monitored by visible markers, between closely related species by continuous backcrosses. This commonly used method, however, suffers from two problems. First, it relies on the availability of markers to monitor the introgressed regions and so the portion of the genome examined is limited to the marked regions. Secondly, the introgressed regions are usually large and it is impossible to tell if the effects of the introgressed regions are the result of single (or few) major genes or many minor genes (polygenes). Here we introduce a simple and general method for identifying putative major hybrid male sterility genes which is free of these problems. In this method, the actual hybrid male sterility genes (rather than markers), or tightly linked gene complexes with large effects, are selectively introgressed from one species into the background of another species by repeated backcrosses. This is performed by selectively backcrossing heterozygous (for hybrid male sterility gene or genes) females producing fertile and sterile sons in roughly equal proportions to males of either parental species. As no marker gene is required for this procedure, this method can be used with any species pairs that produce unisexual sterility. With the application of this method, a small X chromosome region of Drosophila mauritiana which produces complete hybrid male sterility (aspermic testes) in the background of D. simulans was identified. Recombination analysis reveals that this region contains a second major hybrid male sterility gene linked to the forked locus located at either 62.7 +/- 0.66 map units or at the centromere region of the X chromosome of D. mauritiana.

  17. Application of 265-nm UVC LED Lighting to Sterilization of Typical Gram Negative and Positive Bacteria

    NASA Astrophysics Data System (ADS)

    Lee, Yong Wook; Yoon, Hyung Do; Park, Jae-Hyoun; Ryu, Uh-Chan

    2018-05-01

    UV LED lightings have been displacing conventional UV lamps due to their high efficiency, long lifetime, etc. A sterilizing lighting was prepared by assembling a UV LED module composed of 265-nm UVC LEDs and a silica lens array with a driver module comprised of a driver IC controlling pulse width modulation and constant current. The silica lens array was designed and fabricated to focus UV beam and simultaneously to give a uniform light distribution over specimens. Then pasteurizing effect of the lighting was analyzed for four kinds of bacteria and one yeast which are dangerous to people with low immunity. Sterilizing tests on these germs were carried out at the both exposure distances of 10 and 100 mm for various exposure durations up to 600 s.

  18. [Proposal of a costing method for the provision of sterilization in a public hospital].

    PubMed

    Bauler, S; Combe, C; Piallat, M; Laurencin, C; Hida, H

    2011-07-01

    To refine the billing to institutions whose operations of sterilization are outsourced, a sterilization cost approach was developed. The aim of the study is to determine the value of a sterilization unit (one point "S") evolving according to investments, quantities processed, types of instrumentation or packaging. The time of preparation has been selected from all sub-processes of sterilization to determine the value of one point S. The time of preparation of sterilized large and small containers and pouches were raised. The reference time corresponds to one bag (equal to one point S). Simultaneously, the annual operating cost of sterilization was defined and divided into several areas of expenditure: employees, equipments and building depreciation, supplies, and maintenance. A total of 136 crossing times of containers were measured. Time to prepare a pouch has been estimated at one minute (one S). A small container represents four S and a large container represents 10S. By dividing the operating cost of sterilization by the total number of points of sterilization over a given period, the cost of one S can be determined. This method differs from traditional costing method in sterilizing services, considering each item of expenditure. This point S will be the base for billing of subcontracts to other institutions. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  19. Sterilization validation for medical devices at IRASM microbiological laboratory—Practical approaches

    NASA Astrophysics Data System (ADS)

    Trandafir, Laura; Alexandru, Mioara; Constantin, Mihai; Ioniţă, Anca; Zorilă, Florina; Moise, Valentin

    2012-09-01

    EN ISO 11137 established regulations for setting or substantiating the dose for achieving the desired sterility assurance level. The validation studies can be designed in particular for different types of products. Each product needs distinct protocols for bioburden determination and sterility testing. The Microbiological Laboratory from Irradiation Processing Center (IRASM) deals with different types of products, mainly for the VDmax25 method. When it comes to microbiological evaluation the most challenging was cotton gauze. A special situation for establishing the sterilization validation method appears in cases of cotton packed in large quantities. The VDmax25 method cannot be applied for items with average bioburden more than 1000 CFU/pack, irrespective of the weight of the package. This is a method limitation and implies increased costs for the manufacturer when choosing other methods. For microbiological tests, culture condition should be selected in both cases of the bioburden and sterility testing. Details about choosing criteria are given.

  20. [Depyrogenation test regarding inox and glass containers in the preparation of parenteral nutrition mixtures].

    PubMed

    Lajoinie, A; Vasselon, P; Tall, M-L; Salmon, D; Bréant, V; Diouf, E; Pivot, C; Pirot, F

    2012-09-01

    The preparation of parenteral nutrition mixture (PNM) in an open chamber requires the use of intermediate containers sterile and non-pyrogenic. A sterilization of containers by moist heat in large autoclaves is the suitable method. However, sterilization by moist heat is not a depyrogenation method. In our study, we report the validation of a sterilization and depyrogenation method for containers by dry heat using a convection oven. Sterilization and depyrogenation of material by dry heat have been audited by the reduction of at least three logarithms of original endotoxin rate. The containers were initially artificially contaminated with a suspension of endotoxin for 16 hours. Contaminated containers were placed in an oven with revolving heat at 250 °C for 1 hour. After treatment with dry heat, the residual endotoxin levels in the containers were determined by a kinetic chromogenic method. After treatment with dry heat, the average log reductions of endotoxin levels were respectively, for glass and steel containers, 4.78 ± 0.07 and 4.87 ± 0.03. The present validation study confirms the effectiveness of treatment with dry heat for sterilization and depyrogenation of glass and steel containers. This method of sterilization and depyrogenation meets the microbiological quality requirements for the preparation of MNP. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  1. A NEW AUTOCLAVE SYSTEM FOR STERILIZING VITAMIN-FORTIFIED, COMMERCIAL RODENT DIETS WITH LOWER NUTRIENT LOSS.

    DTIC Science & Technology

    would (a) require less time and (b) not destroy vitamins. Feed contaminated with Bacillus stearothermophilus and B. subtilis was sterilized in high...The study was designed to develop a method for sterilizing vitamin-fortified commercial diets for feeding germ-free and defined-flora rodents that...high-prevacuum autoclaves makes possible a reduction in the time required to sterilize autoclavable, commercial diets. Previous methods have required

  2. Cleaning, disinfection and sterilization of surface prion contamination.

    PubMed

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  3. ACOG Practice bulletin no. 133: benefits and risks of sterilization.

    PubMed

    2013-02-01

    Female and male sterilization are both safe and effective methods of permanent contraception used by more than 220 million couples worldwide . Approximately 600,000 tubal occlusions and 200,000 vasectomies are performed in the United States annually . For women seeking permanent contraception, sterilization obviates the need for user-dependent contraception throughout their reproductive years and provides an excellent alternative for those with medical contraindications to reversible methods. The purpose of this document is to review the evidence for the safety and effectiveness of female sterilization in comparison with male sterilization and other forms of contraception.

  4. Evaluation of two disinfection/sterilization methods on silicon rubber-based composite finishing instruments.

    PubMed

    Lacerda, Vánia A; Pereira, Leandro O; Hirata JUNIOR, Raphael; Perez, Cesar R

    2015-12-01

    To evaluate the effectiveness of disinfection/sterilization methods and their effects on polishing capacity, micomorphology, and composition of two different composite fiishing and polishing instruments. Two brands of finishing and polishing instruments (Jiffy and Optimize), were analyzed. For the antimicrobial test, 60 points (30 of each brand) were used for polishing composite restorations and submitted to three different groups of disinfection/sterilization methods: none (control), autoclaving, and immersion in peracetic acid for 60 minutes. The in vitro tests were performed to evaluate the polishing performance on resin composite disks (Amelogen) using a 3D scanner (Talyscan) and to evaluate the effects on the points' surface composition (XRF) and micromorphology (MEV) after completing a polishing and sterilizing routine five times. Both sterilization/disinfection methods were efficient against oral cultivable organisms and no deleterious modification was observed to point surface.

  5. “Everything I Know I Learned from My Mother...or Not”: Perspectives of African-American and White Women on Decisions About Tubal Sterilization

    PubMed Central

    Nikolajski, Cara; Rodriguez, Keri L.; Creinin, Mitchell D.; Arnold, Robert M.; Ibrahim, Said A.

    2008-01-01

    BACKGROUND African-American women have had higher rates of female sterilization compared to white women since its emergence as a contraceptive method. The reasons underlying this observed racial difference are unknown. OBJECTIVES The goals of this study were to (1) explore what factors shape black and white women’s decisions about tubal sterilization as a contraceptive method and (2) generate hypotheses about the relationship of race to the decision-making process. DESIGN We conducted six focus groups stratified by tubal sterilization status and race. During each of the audio-recorded sessions, participants were asked to discuss reasons that women choose sterilization as a contraceptive method. PARTICIPANTS The participants of the study were 24 African-American women and 14 white women. APPROACH Transcripts of the sessions were qualitatively analyzed with particular attention to factors that might be unique to each of the two racial groups. RESULTS Personal factors shaped black and white women’s decisions regarding tubal sterilization. Preference for a convenient, highly effective contraceptive method was the main reason to get a tubal sterilization for women of both racial groups. We also identified socio-cultural differences that might explain why black women are more likely than white women to choose tubal sterilization over other contraceptive methods. An unanticipated, but clinically important, finding was that women often reported feeling that their doctors and the health-care system served as barriers to obtaining the desired procedure. CONCLUSION Socio-cultural differences may help explain why black and white women choose different contraceptive methods. PMID:19107540

  6. How to avoid glucose degradation products in peritoneal dialysis fluids.

    PubMed

    Erixon, Martin; Wieslander, Anders; Lindén, Torbjörn; Carlsson, Ola; Forsbäck, Gunita; Svensson, Eva; Jönsson, Jan Ake; Kjellstrand, Per

    2006-01-01

    The formation of glucose degradation products (GDPs) during sterilization of peritoneal dialysis fluids (PDFs) is one of the most important aspects of biocompatibility of glucose-containing PDFs. Producers of PDFs are thus trying to minimize the level of GDPs in their products. 3,4-Dideoxyglucosone-3-ene (3,4-DGE) has been identified as the most bioreactive GDP in PDFs. It exists in a temperature-dependent equilibrium with a pool of 3-deoxyglucosone (3-DG) and is a precursor in the irreversible formation of 5-hydroxymethyl furaldehyde (5-HMF). The aim of the present study was to investigate how to minimize GDPs in PDFs and how different manufacturers have succeeded in doing so. Glucose solutions at different pHs and concentrations were heat sterilized and 3-DG, 3,4-DGE, 5-HMF, formaldehyde, and acetaldehyde were analyzed. Conventional as well as biocompatible fluids from different manufacturers were analyzed in parallel for GDP concentrations. The concentrations of 3-DG and 3,4-DGE produced during heat sterilization decreased when pH was reduced to about 2. Concentration of 5-HMF decreased when pH was reduced to 2.6. After further decrease to a pH of 2.0, concentration of 5-HMF increased slightly, and below a pH of 2.0 it increased considerably, together with formaldehyde; 3-DG continued to drop and 3,4-DGE remained constant. Inhibition of cell growth was paralleled by 3,4-DGE concentration at pH 2.0 - 6.0. A high glucose concentration lowered concentrations of 3,4-DGE and 3-DG at pH 5.5 and of 5-HMF at pH 1. At pH 2.2 and 3.2, glucose concentration had a minor effect on the formation of GDPs. All conventional PDFs contained high levels of 3,4-DGE and 3-DG. Concentrations were considerably lower in the biocompatible fluids. However, the concentration of 5-H M F was slightly higher in all the biocompatible fluids. The best way to avoid reactive GDPs is to have a pH between 2.0 and 2.6 during sterilization. If pHs outside this range are used, it becomes more important to have high glucose concentration during the sterilization process. There are large variations in GDPs, both within and between biocompatible and conventionally manufactured PDFs.

  7. Sterilization Efficiency of Spore forming Bacteria in Powdery Food by Atmospheric Pressure Plasmas Sterilizer

    NASA Astrophysics Data System (ADS)

    Nagata, Masayoshi; Tanaka, Masashi; Kikuchi, Yusuke

    2015-09-01

    To provide food sterilization method capable of killing highly heat resistant spore forming bacteria, we have studied effects of plasma treatment method at atmospheric pressure in order to develop a new high speed plasma sterilization apparatus with a low cost and a high efficiency. It is also difficult even for the plasma treatment to sterilize powdery food including spices such as soybean, basil and turmeric. This paper describes that an introduction of mechanical rotation of a treatment space increases the efficiency so that perfect inactivation of spore forming bacteria in these materials by a short treatment time has been demonstrated in our experiments. We also will discuss the sterilization mechanism by dielectric barrier discharge.

  8. Sterilization of Exopolysaccharides Produced by Deep-Sea Bacteria: Impact on Their Stability and Degradation

    PubMed Central

    Rederstorff, Emilie; Fatimi, Ahmed; Sinquin, Corinne; Ratiskol, Jacqueline; Merceron, Christophe; Vinatier, Claire; Weiss, Pierre; Colliec-Jouault, Sylvia

    2011-01-01

    Polysaccharides are highly heat-sensitive macromolecules, so high temperature treatments are greatly destructive and cause considerable damage, such as a great decrease in both viscosity and molecular weight of the polymer. The technical feasibility of the production of exopolysaccharides by deep-sea bacteria Vibrio diabolicus and Alteromonas infernus was previously demonstrated using a bioproduct manufacturing process. The objective of this study was to determine which sterilization method, other than heat sterilization, was the most appropriate for these marine exopolysaccharides and was in accordance with bioprocess engineering requirements. Chemical sterilization using low-temperature ethylene oxide and a mixture of ionized gases (plasmas) was compared to the sterilization methods using gamma and beta radiations. The changes to both the physical and chemical properties of the sterilized exopolysaccharides were analyzed. The use of ethylene oxide can be recommended for the sterilization of polysaccharides as a weak effect on both rheological and structural properties was observed. This low-temperature gas sterilizing process is very efficient, giving a good Sterility Assurance Level (SAL), and is also well suited to large-scale compound manufacturing in the pharmaceutical industry. PMID:21566796

  9. Breeding of fragrant cyclamen by interspecific hybridization and ion-beam irradiation.

    PubMed

    Ishizaka, Hiroshi

    2018-01-01

    Conventional breeding of cyclamen has relied on crossings among Cyclamen persicum cultivars without consideration of the scent of the flowers. Cyclamen purpurascens is a wild species with the most fragrant flowers in the genus Cyclamen. Allodiploid (2 n = 2 x = 41, AB) and allotriploid (2 n = 3 x = 65, AAB) plants have been produced from crosses of diploid and autotetraploid cultivars of C. persicum (2 n = 2 x = 48, AA; 4 x = 96, AAAA) × diploid wild C. purpurascens (2 n = 2 x = 34, BB) by embryo rescue, but are sterile. Fertile allotetraploid (2 n = 4 x = 82, AABB) plants have been produced by chromosome doubling of the sterile allodiploids in vitro . Autotetraploid C. purpurascens (2 n = 4 x = 68, BBBB) has been produced by chromosome doubling of diploid C. purpurascens , and other fertile allotetraploids (2 n = 4 x = 82, AABB) have been produced from crosses of autotetraploid cultivars of C. persicum × autotetraploid C. purpurascens by embryo rescue. Commercial cultivars of fragrant cyclamen have been bred by conventional crosses among the allotetraploids. Mutation breeding using ion-beam irradiation combined with plant tissue culture has resulted in fragrant cyclamens with novel flower colors and pigments. In contrast, allotriploids (AAB) have not been commercialized because of seed sterility and poor ornamental value. The flower colors are determined by anthocyanins and flavonol glycosides or chalcone glucoside, and the fragrances are determined by monoterpenes, sesquiterpenes, phenylpropanoids, or aliphatics. Techniques for the production of fragrant cyclamen and knowledge of flower pigments and volatiles will allow innovation in conventional cyclamen breeding.

  10. Reliability of laparoscopic compared with hysteroscopic sterilization at 1 year: a decision analysis.

    PubMed

    Gariepy, Aileen M; Creinin, Mitchell D; Schwarz, Eleanor B; Smith, Kenneth J

    2011-08-01

    To estimate the probability of successful sterilization after an hysteroscopic or laparoscopic sterilization procedure. An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. In the base case analysis, the proportion of women having a successful sterilization procedure on the first attempt is 99% for laparoscopic sterilization, 88% for hysteroscopic sterilization in the operating room, and 87% for hysteroscopic sterilization in the office. The probability of having a successful sterilization procedure within 1 year is 99% with laparoscopic sterilization, 95% for hysteroscopic sterilization in the operating room, and 94% for hysteroscopic sterilization in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within 1 year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization.

  11. Reversibility of female sterilization.

    PubMed

    Siegler, A M; Hulka, J; Peretz, A

    1985-04-01

    The discussion considers the current status of reversibility of sterilization in the US and describes clinical and experimental efforts for developing techniques designed for reversibility. It focuses on regret following sterilization, reversal potential of current sterilization techniques, patient selection, current reversal techniques, results of sterilization procedures, experimental approaches to reversal of current techniques of sterilization, and sterilization procedures devised for reversibility, in humans and in animals. Request is the 1st stage of reversal, but a request for sterilization reversal (SR) does not always mean regret for a decision made at the time. Frequently it is a wish to restore fertility because life circumstances have changed after a sterilization that was ppropriate at the time it was performed. Schwyhart and Kutner reviewed 22 studies published between 1949-69 in which they found that the percentage of patients regretting the procedure ranged from 1.3-15%. Requests for reversal remain low in most countries, but if sterilization becomes a more popular method of contraception, requests will also increase. The ideal operation considered as a reversaible method of sterilization should include an easy, reliable outpatient method of tubal occlusion with miniml risk or patient discomfort that subsequently could be reversed without the need for a major surgical intervention. Endoscopic methods have progressed toward the 1st objective. A recent search of the literature uncovered few series of SR of more than 50 cases. The 767 operations found were analyzed with regard to pregnancy outcome. The precent of live births varied from 74-78.8%, and the occurance of tubal pregnancies ranged from 1.7-6.5%. All of the confounding variables in patient selection and small numbers of reported procedures preclude any conclusion about the different techniques or the number of operations that give a surgeon a level of expertise. Few authors classify their results of SR according to the original sterilization procedure. The most commonly performed sterilization (Pomeroy) was the most frequently reported to have undergone a reversal attempt, with a 50% success rate based on term or intrauterine pregnancies. Electrocoagulation was the next most frequent technique for reversal, with a 41% success rate. The less destrictive mechanical tehcniques, clip and band, had a reversal rate of 84% and 72%, respectively. A table summarizes sterilization procedures devised for reversibility in women. A women seeking sterilization should be advised that sterilization is permanent if no further tubal surgery is performed and that reversal is possible but involves a major and expensive operation.

  12. Investigation of methods for sterilization of potting compounds and mated surfaces

    NASA Technical Reports Server (NTRS)

    Tulius, J. J.; Daley, D. J.; Phillips, G. B.

    1972-01-01

    The feasibility of using formaldehyde-liberating synthetic resins or polymers for the sterilization of potting compounds, mated and occluded areas, and spacecraft surfaces was demonstrated. The detailed study of interrelated parameters of formaldehyde gas sterilization revealed that efficient cycle conditions can be developed for the sterilization of spacecraft components. It was determined that certain parameters were more important than others in the development of cycles for specific applications. The use of formaldehyde gas for the sterilization of spacecraft components provides NASA with a highly efficient method which is inexpensive, reproducible, easily quantitated, materials compatible, operationally simple, generally non-hazardous and not thermally destructive.

  13. Sterilization in the United States

    PubMed Central

    Bartz, Deborah; Greenberg, James A

    2008-01-01

    Unintended pregnancies are expensive for patients and for society in terms of medical costs, the cost of caring for more children, and the cost to personal and professional goals. Sterilization is the most common contraceptive method utilized by couples in the United States. Given technological advances over the past few decades, male and female surgical sterilization has become a safe, convenient, easy, and highly effective birth control method for the long term. This article reviews current male and female sterilization options. PMID:18701927

  14. Effect of two-chambered bicarbonate lactate-buffered peritoneal dialysis fluids on peripheral blood mononuclear cell and polymorphonuclear cell function in vitro.

    PubMed

    Sundaram, S; Cendoroglo, M; Cooker, L A; Jaber, B L; Faict, D; Holmes, C J; Pereira, B J

    1997-11-01

    Low pH, high osmolality, increasing glucose concentration, and glucose degradation products (GDP) formed during heat sterilization of conventional peritoneal dialysis (PD) fluids have been shown to have a detrimental effect on cells involved in peritoneal host defense. The two-chambered PD fluid bag in which glucose at pH approximately 3 is separated from a bicarbonate (25 mmol/L)-lactate (15 mmol/L) buffer during heat sterilization permits PD fluids with lower GDP to be delivered to the patient at neutral pH. To establish the possible benefit of two-chambered bag PD fluids on peripheral blood mononuclear cell (PBMC) and polymorphonuclear (PMN) cell function, we compared conventional 1.5% Dianeal (1.5%D) with 1.5% two-chambered bag bicarbonate-lactate (1.5%D-B), and conventional 4.25% Dianeal (4.25%D) with 4.25% two-chambered bag bicarbonate-lactate (4.25%D-B). Furthermore, to study the effect of the sterilization process on PBMC and PMN function, we compared filter-sterilized 4.25%D (4.25%D-F) with 4.25%D and 4.25%D-B. PBMC were harvested by Ficoll-Hypaque separation, and 2.5 x 10(6) cells in RPMI were incubated with an equal volume of the test fluids for 4 hours, pelleted, and resuspended in RPMI containing 10 ng endotoxin for a further 20 hours. Tumor necrosis factor alpha (TNF-alpha) production by endotoxin-stimulated PBMC was not significantly different (P = 0.10) between 1.5%D-B and 1.5%D, but was significantly higher (P = 0.01) with 4.25%D-B compared with 4.25%D. PBMC exposed to filter-sterilized fluid (4.25%D-F) showed significantly higher endotoxin-stimulated TNF-alpha production compared with 4.25%D (P = 0.02), but was not significantly different from 4.25%D-B (P = 0.40). PMN were harvested by Ficoll-Hypaque separation and 10 x 10(6) cells incubated with test fluids for 30 minutes. After incubation, phagocytosis (phagocytosis index) was determined by the uptake of 14C-labeled Staphylococcus aureus, oxidative burst by reduction of ferricytochrome C to ferrocytochrome C on stimulation with PMA, and enzyme release by measurement of endotoxin-stimulated bactericidal/permeability increasing protein (BPI). Bicarbonate-lactate two-chambered fluids of similar osmolality and glucose concentration conferred a significant improvement in phagocytosis (P = 0.02 for 1.5%D-B and P < 0.001 for 4.25%D-B). Oxidative burst and BPI release were significantly higher in 4.25%D-B compared with 4.25%D (P < 0.001). Filter-sterilized 4.25%D-F conferred a significant improvement in phagocytosis and oxidative burst compared with 4.25%D (P < 0.001) or 4.25%D-B (P < 0.001). Furthermore, conventional 4.25%D was associated with significantly lower BPI release compared with 4.25%D-F (P = 0.01). GDP's acetaldehyde and 5-HMF were analyzed in 4.25%D-B, 4.25%D, and 4.25%D-F. Acetaldehyde was below the lower limit (0.79 ppm) of the standard curve in 4.25%D-B and 4.25%D-F fluids but was detected (3.76 to 5.12 ppm) in all of the 4.25%D fluids. Relative levels of 5-HMF in the 4.25%D-B (0.032 to 0.041 Abs @ 284 nm) and 4.25%D (0.031 to 0.036 Abs @ 284 nm) were similar. The lowest levels (0.001 Abs @ 284 nm) were observed in the filter-sterilized 4.25%D-F. The beneficial effects of two-chambered bicarbonate lactate-buffered PD fluids on PBMC and PMN function are probably related to reduction of GDP from heat sterilization of glucose in a separate chamber at a lower pH. This improvement in biocompatibility could have a beneficial affect on peritoneal defenses.

  15. The Use of Long Acting Reversible Contraceptives and the Relationship between Discontinuation Rates due to Menopause and to Female and Male Sterilizations.

    PubMed

    Ferreira, Jessica Mayra; Monteiro, Ilza; Castro, Sara; Villarroel, Marina; Silveira, Carolina; Bahamondes, Luis

    2016-05-01

    Introduction Women require effective contraception until they reach menopause. The long acting reversible contraceptives (LARC) and the depot-medroxyprogesterone acetate (DMPA, Depo-Provera®, Pfizer, Puurs, Belgium) are great options and can replace possible sterilizations. Purpose To assess the relationship between the use of LARCs and DMPA and terminations ascribed to menopause and sterilizations in a Brazilian clinic. Methods We reviewed the records of women between 12 and 50 years of age attending the clinic that chose to use a LARC method or DMPA. Cumulative termination rates due to sterilization or because the woman had reached menopause were computed using single decrement life-table analysis over 32 years. We also examined all records of surgical sterilization at our hospital between the years 1980-2012. Results Three hundred thirty-two women had continuously used the same contraceptive until menopause, and 555 women had discontinued the method because they or their partners underwent sterilization. From year 20 to year 30 of use, levonorgestrel intrauterine-releasing system (LNG-IUS - Mirena®, Bayer Oy, Turku, Finland; available since 1980), copper intrauterine device (IUD - available since 1980) and DMPA users showed a trend of cumulative higher discontinuation rates due to menopause when compared with the discontinuation rates due to sterilization. Over the study period, a steep decline in the use of sterilization occurred. Conclusion Over the past 15 years of research we have observed a trend: women usually preferred to continue using LARC methods or DMPA until menopause rather than decide for sterilization, be it their own, or their partners'. The annual number of sterilizations dropped in the same period. The use of LARC methods and DMPA until menopause is an important option to avoid sterilization, which requires a surgical procedure with potential complications. Thieme Publicações Ltda Rio de Janeiro, Brazil.

  16. Contraceptive use and preferences of young married women in Kerala, India.

    PubMed

    Thulaseedharan, Jissa Vinoda

    2018-01-01

    As in other states of India, female sterilization is the most widely used contraceptive method in Kerala where women have higher levels of education compared to most other states in India. This paper describes the use and preferences of contraceptive methods among young married women in Trivandrum district, Kerala, India. A community-based cross-sectional survey was carried out among 203 young married women (18-28 years) during January-March 2015 using multistage cluster sampling method. Statistical analysis was mainly descriptive, and chi-squared test was used to test the statistical significance of the relationship between sociodemographic factors and contraceptive use. The average age at marriage for women was 21.3 years, and 23% of women had more than one child. Current use of any contraceptive methods was 58%. Female sterilization was preferred by 13% and it was significantly higher among women aged 25-28 years than in those aged 18-24 years (20% vs 2.6%, p <0.001). Female sterilization was significantly lower among women with higher levels of education than in women with an education level of plus two or below (5.8% vs 19%, p =0.006). Women were mostly in favor of female sterilization (91%), and a significantly lower proportion of highly educated women preferred female sterilization than women with an education of 12 years or below (85% vs 95.7%, p =0.008). A considerable number of females in the age group 25-28-years opting for sterilization and the unique preference for female sterilization when the family size is complete show the predominant reliance on female sterilization among young women. Higher education delays sterilization in young women due to delayed marriage and childbirth. Women empowerment, proper information and assuring availability and accessibility to different methods can gradually change the dominant preference for female-oriented permanent method of contraception.

  17. Simplified method for preparation of concentrated exoproteins produced by Staphylococcus aureus grown on surface of cellophane bag containing liquid medium.

    PubMed

    Ikigai, H; Seki, K; Nishihara, S; Masuda, S

    1988-01-01

    A simplified method for preparation of concentrated exoproteins including protein A and alpha-toxin produced by Staphylococcus aureus was successfully devised. The concentrated proteins were obtained by cultivating S. aureus organisms on the surface of a liquid medium-containing cellophane bag enclosed in a sterilized glass flask. With the same amount of medium, the total amount of proteins obtained by the method presented here was identical with that obtained by conventional liquid culture. The concentration of proteins obtained by the method, however, was high enough to observe their distinct bands stained on polyacrylamide gel electrophoresis. This method was considered quite useful not only for large-scale cultivation for the purification of staphylococcal proteins but also for small-scale study using the proteins. The precise description of the method was presented and its possible usefulness was discussed.

  18. Investigating steam penetration using thermometric methods in dental handpieces with narrow internal lumens during sterilizing processes with non-vacuum or vacuum processes.

    PubMed

    Winter, S; Smith, A; Lappin, D; McDonagh, G; Kirk, B

    2017-12-01

    Dental handpieces are required to be sterilized between patient use. Vacuum steam sterilization processes with fractionated pre/post-vacuum phases or unique cycles for specified medical devices are required for hollow instruments with internal lumens to assure successful air removal. Entrapped air will compromise achievement of required sterilization conditions. Many countries and professional organizations still advocate non-vacuum sterilization processes for these devices. To investigate non-vacuum downward/gravity displacement, type-N steam sterilization of dental handpieces, using thermometric methods to measure time to achieve sterilization temperature at different handpiece locations. Measurements at different positions within air turbines were undertaken with thermocouples and data loggers. Two examples of widely used UK benchtop steam sterilizers were tested: a non-vacuum benchtop sterilizer (Little Sister 3; Eschmann, Lancing, UK) and a vacuum benchtop sterilizer (Lisa; W&H, Bürmoos, Austria). Each sterilizer cycle was completed with three handpieces and each cycle in triplicate. A total of 140 measurements inside dental handpiece lumens were recorded. The non-vacuum process failed (time range: 0-150 s) to reliably achieve sterilization temperatures within the time limit specified by the international standard (15 s equilibration time). The measurement point at the base of the handpiece failed in all test runs (N = 9) to meet the standard. No failures were detected with the vacuum steam sterilization type B process with fractionated pre-vacuum and post-vacuum phases. Non-vacuum downward/gravity displacement, type-N steam sterilization processes are unreliable in achieving sterilization conditions inside dental handpieces, and the base of the handpiece is the site most likely to fail. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  19. Feasibility study of the sterilization of pigskin used as wound dressings by neutral electrolyzed water.

    PubMed

    Ge, Liangpeng; Zhang, Xiaochun; Cao, Chuan; Gu, Zhaobin; Liu, Zuohua; Liu, Lubin; Lin, Baozhong

    2012-06-01

    Neutral electrolyzed water (NEW) is considered to be a high-level biodegradable disinfectant with sporicidal, bactericidal, and virucidal activity. It has also been reported to accelerate wound healing; thus, it is particularly attractive for the elimination or minimization of the microbial population of skin grafts to be used as wound dressings. Pigskins were sterilized with different concentrations of NEW and with different methods. The feasibility of pigskin sterilization by NEW was evaluated through microbiological analyses, viability assays, histologic assessments, contact cytotoxicity assays, and extract cytotoxicity assays. NEW has strong bactericidal effects on pigskin microorganisms, does not change skin graft histologic properties, and has no cytotoxicity; however, skin viability was significantly reduced after NEW treatment. Although NEW treatment is a very safe and effective method for nonviable pigskin dressing sterilization, to obtain a complete sterilization of pigskin grafts, available chlorine concentration of NEW as well as sterilization time and methods should be optimized. Copyright © 2012 by Lippincott Williams & Wilkins.

  20. Disinfection and Sterilization in Health Care Facilities: An Overview and Current Issues.

    PubMed

    Rutala, William A; Weber, David J

    2016-09-01

    When properly used, disinfection and sterilization can ensure the safe use of invasive and noninvasive medical devices. The method of disinfection and sterilization depends on the intended use of the medical device: critical items (contact sterile tissue) must be sterilized before use; semicritical items (contact mucous membranes or nonintact skin) must be high-level disinfected; and noncritical items (contact intact skin) should receive low-level disinfection. Cleaning should always precede high-level disinfection and sterilization. Current disinfection and sterilization guidelines must be strictly followed. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Effect of Tubal Sterilization Technique on Risk of Serous Ovarian and Primary Peritoneal Carcinoma

    PubMed Central

    LESSARD-ANDERSON, Collette R.; HANDLOGTEN, Kathryn S.; MOLITOR, Rochelle J.; DOWDY, Sean C.; CLIBY, William A.; WEAVER, Amy L.; SAUVER, Jennifer ST.; BAKKUM-GAMEZ, Jamie N.

    2014-01-01

    Objective To determine the effect of excisional tubal sterilization on subsequent development of serous epithelial ovarian cancer (EOC) or primary peritoneal cancer (PPC). Methods We performed a population-based, nested case-control study using the Rochester Epidemiology Project. We identified all patients with a diagnosis of serous EOC or PPC from 1966 through 2009. Each case was age-matched to 2 controls without either diagnosis. Odds ratios (ORs) and corresponding 95% CIs were estimated from conditional logistic regression models. Models were adjusted for prior hysterectomy, prior salpingo-oophorectomy, oral contraceptive use, endometriosis, infertility, gravidity, and parity. Results In total, we identified 194 cases of serous EOC and PPC during the study period and matched them with 388 controls (mean [SD] age, 61.4 [15.2] years). Fourteen cases (7.2%) and 46 controls (11.9%) had undergone tubal sterilization. Adjusted risk of serous EOC or PPC was slightly lower after any tubal sterilization (OR, 0.59 [95% CI, 0.29–1.17]; P=.13). The rate of excisional tubal sterilization was lower in cases than controls (2.6% vs 6.4%). Adjusted risk of serous EOC and PPC was decreased by 64% after excisional tubal sterilization (OR, 0.36 [95% CI, 0.13–1.02]; P=.054) compared with those without sterilization or with nonexcisional tubal sterilization. Conclusions We present a population-based investigation of the effects of excisional tubal sterilization on the risk of serous EOC and PPC. Excisional methods may confer greater risk reduction than other sterilization methods. PMID:25316178

  2. Training of residents in laparoscopic tubal sterilization: Long-term failure rates

    PubMed Central

    Rackow, Beth W.; Rhee, Maria C.; Taylor, Hugh S.

    2011-01-01

    Objectives Laparoscopic tubal sterilization with bipolar coagulation is a common and effective method of contraception, and a procedure much used to teach laparoscopic surgical skills to Obstetrics and Gynaecology residents (trainees); but it has an inherent risk of failure. This study investigated the long-term failure rate of this procedure when performed by Obstetrics and Gynaecology residents on women treated in their teaching clinics. Methods From 1991 to 1994, Obstetrics and Gynaecology residents carried out 386 laparoscopic tubal sterilizations with bipolar coagulation at Yale-New Haven Hospital. Six to nine years after the procedure, the women concerned were contacted by telephone and data were collected about sterilization failure. Results Two failures of laparoscopic tubal sterilization with bipolar coagulation were identified: an ectopic pregnancy and a spontaneous abortion. For this time period, the long-term sterilization failure rate was 1.9% (0–4.4%). Conclusions The long-term sterilization failure rate for laparoscopic tubal sterilization with bipolar coagulation performed by residents is comparable to the results of prior studies. These findings can be used to properly counsel women at a teaching clinic about the risks of sterilization failure with this procedure, and attest to the adequacy of residents’ training and supervision. PMID:18465476

  3. Use of containers with sterilizing filter in autologous serum eyedrops.

    PubMed

    López-García, José S; García-Lozano, Isabel

    2012-11-01

    To assess the effect of the use of containers with an adapted sterilizing filter on the contamination of autologous serum eyedrops. Prospective, consecutive, comparative, and randomized study. Thirty patients with Sjögren syndrome. One hundred seventy-six autologous serum containers used in home therapy were studied; 48 of them included an adapted filter (Hyabak; Thea, Clermont-Ferrand, France), and the other 128 were conventional containers. Containers equipped with a filter were tested at 7, 14, 21, and 28 days of use, whereas conventional containers were studied after 7 days of use. In addition, testing for contamination was carried out in 14 conventional containers used during in-patient therapy every week for 4 weeks. In all cases, the preparation of the autologous serum was similar. Blood agar and chocolate agar were used as regular culture media for the microbiologic studies, whereas Sabouraud agar with chloramphenicol was the medium for fungal studies. Microbiologic contamination of containers with autologous serum eyedrops. Only one of the containers with an adapted sterilizing filter (2.1%) became contaminated with Staphylococcus epidermidis after 1 month of treatment, whereas the contamination rate among conventional containers reached 28.9% after 7 days of treatment. The most frequent germs found in the samples were coagulase-negative Staphylococcus (48.6%). With regard the containers used in the in-patient setting, 2 (14.3%) became contaminated after 2 weeks, 5 (35.7%) became contaminated after 3 weeks, and 5 (50%) became contaminated after 4 weeks, leaving 7 (50%) that did not become contaminated after 1 month of treatment. Using containers with an adapted filter significantly reduces the contamination rates in autologous serum eyedrops, thus extending the use of such container by the patients for up to 4 weeks with virtually no contamination risks. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  4. Observation of Effectiveness of Clinical Sterilization by CASP-80A Low-Temperature Plasma Sterilizer

    NASA Astrophysics Data System (ADS)

    Li, Si; Zhang, Yangde; Liu, Weidong

    2006-09-01

    The influence on the effectiveness of sterilization by low-temperature plasma sterilizer CASP-80A was investigated so as to provide a theoretical basis for reducing medical costs and achieving ideal sterilization effectiveness. To conduct the on-site simulation test, a clinical material sterilization test and a test of the influence of organic substance were conducted, the former by using the representative of Bacillus Stearothermophilus, preparing the bacteria-contaminated carrier through polytetrafluoroethylene (PTFE) simulated hose endoscopes, and the latter by using calf serum as the influence factor of the organic substance. The results show that the CASP-80A low-temperature plasma sterilizer could achieve effective sterilization by either the short-cycle or the long-cycle sterilization method depending on different materials, apparatus, and extent of contamination. The organic substances could influence the effectiveness of sterilization by the low-temperature plasma (H2O2) sterilizer.

  5. System and method of applying energetic ions for sterilization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmidt, John A.

    2003-12-23

    A method of sterilization of a container is provided whereby a cold plasma is caused to be disposed near a surface to be sterilized, and the cold plasma is then subjected to a pulsed voltage differential for producing energized ions in the plasma. Those energized ions then operate to achieve spore destruction on the surface to be sterilized. Further, a system for sterilization of a container which includes a conductive or non-conductive container, a cold plasma in proximity to the container, and a high voltage source for delivering a pulsed voltage differential between an electrode and the container and acrossmore » the cold plasma, is provided.« less

  6. Women's Awareness of, Interest in, and Experiences with Long-acting Reversible and Permanent Contraception.

    PubMed

    Burns, Bridgit; Grindlay, Kate; Dennis, Amanda

    2015-01-01

    Long-acting reversible contraception (LARC) and sterilization are popular contraceptive methods. However, they have been associated with safety concerns and coercive practices. We aimed to understand women's opinions and experiences related to these methods, including whether the methods' fraught histories influence use or interest. Between May and July 2013, we conducted an online survey with a convenience sample of 520 women aged 14 to 45. We used quota sampling to ensure women of color were at least 60% of our sample. Descriptive statistics, χ(2) tests, and multivariable logistic regression were used to estimate participants' awareness of, interest in, and experiences with LARCs and sterilization. Overall, 30% of women reported current LARC use and 67% interest in future LARC use. Four percent reported sterilization use and 48% interest in future sterilization. In multivariate analyses, current LARC use was lower among Asian women versus White women (odds ratio [OR], 0.24), and interest in future use was higher among women aged 14 to 24 versus 35 to 45 (OR, 5.49). Interest in sterilization was higher among women aged 14 to 24 and 25 to 34 versus 35 to 45 (ORs, 3.29-3.66) and women with disabilities (OR, 1.64), and lower among Black compared with White women (OR, 0.41). Method misperceptions were evident, and concerns about contraceptive coercion were reported. Concerns about contraceptive coercion were not predominant reasons for noninterest in LARCs and sterilization, but were reported by some participants. Lower sterilization interest among Black women and higher sterilization interest among women with disabilities warrant further research. Efforts to address misperceptions about LARCs and sterilization, including their safety and efficacy, are needed. Copyright © 2015 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  7. [Use of and verification with biological indicators in sterilizers belonging to dentistry surgeons from San Luis Potosi, Mexico].

    PubMed

    Patiño-Marín, N; Loyola-Rodríguez, J P; Tovar-Reyes, L F

    2001-01-01

    To assess the utilization of sterilizing equipment used by dentists, and verification of sterilization using biological indicators. A cross-sectional study was conducted in 1999-2000, among 130 (65%) dentists having sterilizing equipment, at Facultad de Estomatología, Universidad Autónoma de San Luis Potosí and Colegio Dental Potosino. Biological indicators for sterilization containing Bacillus subtilis and Bacillus stearothermophilus were used. Thirty autoclaves and 100 dry-heat sterilizers were evaluated: 23 (17.7%) of them showed bacterial growth. Twenty-one (16.1%) dentists already were using biological indicators to verify their sterilizing equipment. Both sterilization methods were found to allow bacterial growth with similar frequencies (p = > 0.66). Few dentists verify the quality of sterilization process through biological indicators; bacterial growth and failure of sterilization were evidenced.

  8. Impact of autoclave sterilization on the activity and structure of formulated heparin.

    PubMed

    Beaudet, Julie M; Weyers, Amanda; Solakyildirim, Kemal; Yang, Bo; Takieddin, Majde; Mousa, Shaker; Zhang, Fuming; Linhardt, Robert J

    2011-08-01

    The stability of a formulated heparin was examined during its sterilization by autoclaving. A new method to follow loss in heparin binding to the serine protease inhibitor, antithrombin III, and the serine protease, thrombin, was developed using a surface plasmon resonance competitive binding assay. This loss in binding affinity correlated well with loss in antifactor IIa (thrombin) activity as well as antifactor Xa activity as measured using conventional amidolytic assays. Autoclaving also resulted in a modest breakdown of the heparin backbone as confirmed by a slight reduction in number-averaged and weight-averaged molecular weight and an increase in polydispersity. Although no clear changes were observed by nuclear magnetic resonance spectroscopy, disaccharide composition analysis using high-performance liquid chromatography-electrospray ionization-mass spectrometry suggested that loss of selected sulfo groups had taken place. It is this sulfo group loss that probably accounts for a decrease in the binding of autoclaved heparin to antithrombin III and thrombin as well as the observed decrease in its amidolytic activity. Copyright © 2011 Wiley-Liss, Inc.

  9. Research progress on the effect of microwave sterilization on agricultural products quality

    NASA Astrophysics Data System (ADS)

    Zhu, Xiang-hao; Yang, Yu-xia; Duan, Zhen-hua

    2018-02-01

    Different sterilization methods have different effects on the quality of agricultural products, microwave sterilization inhibited or eliminated microorganism by the use of microwave thermal effects and non-thermal. In this paper, the effects of microwave sterilization on the quality of fruits and vegetables, dairy, meat, grain, aquatic products and other agricultural products were introduced, and the possible development trends of microwave sterilization in agricultural products processing application were put forward.

  10. System for creating at a site, remote from a sterile environment, a parenteral solution

    NASA Technical Reports Server (NTRS)

    Scharf, Mike (Inventor); Finley, Mike (Inventor); Veillon, Joe (Inventor); Kipp, Jim (Inventor); Dudar, Tom (Inventor); Owens, Jim (Inventor); Ogle, Jim (Inventor)

    1996-01-01

    The present invention relates to a container, system, and method for creating parenteral solutions at a site, remote from sterile environments. The system includes a flexible container that is empty except for a prepackaged amount of a solute that is housed in the interior of the container. The container includes at least one port and a sterilizing filter in communication with an interior of the port. The container is so constructed and arranged that a fluid flow path is created from the port through the filter and into the interior of the container. A sterile water source including means for establishing fluid flow from the sterile water source into the port is provided. Accordingly, sterile water can flow from the sterile water source through the filter into the container where it is mixed with the solute to create a parenteral solution that can then be infused into a patient. A method and container are also provided.

  11. The possible contamination of Jupiter

    NASA Technical Reports Server (NTRS)

    Garcia, Joe

    1988-01-01

    The Galileo probe, though at present its future is uncertain, would, if not sterilized, represent a good chance of contaminating Jupiter. Most scientists opposed to sterilizing the probe argue that to order the probe sterilized would be the death of the project, since sterilization would entail a reconstruction of the probe, and there are not enough funds to accomplish this. These scientists, however, are ignoring a relatively simple and inexpensive alternative to the traditional heat sterilization method. The main threat of contamination comes from Galileo's exterior surfaces: the shell of the probe and its parachute. The probe innermost components would not represent a threat since the probe is sealed. In light of the fact that only the exterior of Galileo would have to be sterilized, heat would not have to be used as a method of sterilization. Instead, various gas mixtures could be sprayed entirely over the probe and its parachute, gases which would kill any and all bacteria. This idea is more thoroughly examined.

  12. Reusable autoclavable silicone rubber dish for insect dissection

    Treesearch

    J.D. Podgwaite; R.D. Neely; R.T. Zerillo

    1974-01-01

    During a disease-diagnosis study which involved a large number of gypsy moth larvae, Porthetria dispar (L.),it became necessary to develop a dissecting dish that, while possessing the positive attributes of conventional wax and paraffin dishes, also could be sterilized and reused.

  13. Sterilization by pure oxygen plasma and by oxygen-hydrogen peroxide plasma: an efficacy study.

    PubMed

    Boscariol, M R; Moreira, A J; Mansano, R D; Kikuchi, I S; Pinto, T J A

    2008-04-02

    Plasma is an innovative sterilization method characterized by a low toxicity to operators and patients, and also by its operation at temperatures close to room temperatures. The use of different parameters for this method of sterilization and the corresponding results were analyzed in this study. A low-pressure inductive discharge was used to study the plasma sterilization processes. Oxygen and a mixture of oxygen and hydrogen peroxide were used as plasma source gases. The efficacy of the processes using different combinations of parameters such as plasma-generation method, type of gas, pressure, gas flow rate, temperature, power, and exposure time was evaluated. Two phases were developed for the processes, one using pure oxygen and the other a mixture of gases. Bacillus subtilis var. niger ATCC 9372 (Bacillus atrophaeus) spores inoculated on glass coverslips were used as biological indicators to evaluate the efficacy of the processes. All cycles were carried out in triplicate for different sublethal exposure times to calculate the D value by the enumeration method. The pour-plate technique was used to quantify the spores. D values of between 8 and 3 min were obtained. Best results were achieved at high power levels (350 and 400 W) using pure oxygen, showing that plasma sterilization is a promising alternative to other sterilization methods.

  14. Comparison of three different sterilization and disinfection methods on orthodontic markers

    PubMed Central

    Omidkhoda, Maryam; Rashed, Roozbeh; Bagheri, Zahra; Ghazvini, Kiarash; Shafaee, Hooman

    2016-01-01

    Background: Marking pencils which are frequently used in orthodontics may cause microbial contamination. The purpose of this study was to evaluate and compare the effectiveness of three disinfection and sterilization methods (autoclave, glutaraldehyde solution, and Deconex spray) on orthodontic markers. Materials and Methods: One hundred and twenty orthodontic markers were divided into four groups each 30 pencils: One control group and three groups for three different disinfection/sterilization methods. To evaluate the effectiveness of these methods, pencils were initially contaminated by common pathogen by immersing the pencils in a suspension containing 1.5 × 108 CFU/ml organisms. Then, the pencils were subjected to corresponding disinfection/sterilization methods, and the number of remaining microorganisms was calculated and compared with control group. Results: In the control group, the mean number of Escherichia coli was significantly higher than the other two microorganisms (P = 0.01, P = 0.031). However, the mean numbers of Staphylococcus aureus and Candida albicans were not significantly different (P = 0.1). After sterilization with autoclave and glutaraldehyde, no microbial growth was observed, whereas after disinfection with Deconx spray some colonies of microorganisms still could be observed. Conclusion: Autoclaving and glutaraldehyde solution are the best methods for disinfecting orthodontic markers. PMID:26998472

  15. Rapid inactivation of Penicillium digitatum spores using high-density nonequilibrium atmospheric pressure plasma

    NASA Astrophysics Data System (ADS)

    Iseki, Sachiko; Ohta, Takayuki; Aomatsu, Akiyoshi; Ito, Masafumi; Kano, Hiroyuki; Higashijima, Yasuhiro; Hori, Masaru

    2010-04-01

    A promising, environmentally safe method for inactivating fungal spores of Penicillium digitatum, a difficult-to-inactivate food spoilage microorganism, was developed using a high-density nonequilibrium atmospheric pressure plasma (NEAPP). The NEAPP employing Ar gas had a high electron density on the order of 1015 cm-3. The spores were successfully and rapidly inactivated using the NEAPP, with a decimal reduction time in spores (D value) of 1.7 min. The contributions of ozone and UV radiation on the inactivation of the spores were evaluated and concluded to be not dominant, which was fundamentally different from the conventional sterilizations.

  16. Rapid inactivation of Penicillium digitatum spores using high-density nonequilibrium atmospheric pressure plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iseki, Sachiko; Hori, Masaru; Ohta, Takayuki

    2010-04-12

    A promising, environmentally safe method for inactivating fungal spores of Penicillium digitatum, a difficult-to-inactivate food spoilage microorganism, was developed using a high-density nonequilibrium atmospheric pressure plasma (NEAPP). The NEAPP employing Ar gas had a high electron density on the order of 10{sup 15} cm{sup -3}. The spores were successfully and rapidly inactivated using the NEAPP, with a decimal reduction time in spores (D value) of 1.7 min. The contributions of ozone and UV radiation on the inactivation of the spores were evaluated and concluded to be not dominant, which was fundamentally different from the conventional sterilizations.

  17. Supercritical carbon dioxide-based sterilization of decellularized heart valves

    PubMed Central

    Hennessy, Ryan S.; Jana, Soumen; Tefft, Brandon J.; Helder, Meghana R.; Young, Melissa D.; Hennessy, Rebecca R.; Stoyles, Nicholas J.; Lerman, Amir

    2017-01-01

    Objective The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Background Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Methods Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Results Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Conclusions Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Summary Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile using histology, microbe culture and electron microscopy assays. The cusp tensile properties of supercritical carbon dioxide treated valves were higher compared to valves treated with other techniques. Superior sterility and integrity was found in the decellularized valves treated with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. PMID:28337488

  18. Irradiation biology of male brown marmorated stink bugs: is there scope for the sterile insect technique?

    PubMed

    Welsh, T J; Stringer, L D; Caldwell, R; Carpenter, J E; Suckling, D M

    2017-12-01

    Brown marmorated stink bugs, Halyomorpha halys Stål (Hemiptera: Pentatomidae), are regularly intercepted, but there are few eradication tools. Currently, no sterile insect technique program exists for Hemiptera. Adult males were irradiated at 4-60 Gy, mated and their progeny reared for two generations, with mortality assessed at F 1 egg, F 1 adult and F 2 egg stages. The F 1 eggs showed a dose response to irradiation between 4 and 36 Gy, with 97% sterility at 16 Gy, and higher doses producing complete egg mortality. Only rare F 1 survivors had progeny, but the F 2 generation showed identical responses between maternal and paternal lines; most egg batches showed either very low or very high mortality. Irradiation with 16 Gy resulted in 98.5% sterility, cumulative over F 1 and F 2 . Lack of a dose response at the F 2 generation precludes the use of irradiation-induced inherited sterility. The conventional sterile insect technique appears possible by irradiation of males from ∼12 to 16 Gy. The effect of radiation dose on females is not known, thus we cannot conclude whether bi-sex release is feasible so for now the release of males only is recommended. More work is needed on the competitive fitness of irradiated males, and logistics such as mass rearing or field collection, in order to determine the feasibility of the approach.

  19. The effect of sterilization methods on the physical properties of silk sericin scaffolds.

    PubMed

    Siritientong, Tippawan; Srichana, Teerapol; Aramwit, Pornanong

    2011-06-01

    Protein-based biomaterials respond differently to sterilization methods. Since protein is a complex structure, heat, or irradiation may result in the loss of its physical or biological properties. Recent investigations have shown that sericin, a degumming silk protein, can be successfully formed into a 3-D scaffolds after mixing with other polymers which can be applied in skin tissue engineering. The objective of this study was to investigate the effectiveness of ethanol, ethylene oxide (EtO) and gamma irradiation on the sterilization of sericin scaffolds. The influence of these sterilization methods on the physical properties such as pore size, scaffold dimensions, swelling and mechanical properties, as well as the amount of sericin released from sericin/polyvinyl alcohol/glycerin scaffolds, were also investigated. Ethanol treatment was ineffective for sericin scaffold sterilization whereas gamma irradiation was the most effective technique for scaffold sterilization. Moreover, ethanol also caused significant changes in pore size resulting from shrinkage of the scaffold. Gamma-irradiated samples exhibited the highest swelling property, but they also lost the greatest amount of weight after immersion for 24 h compared with scaffolds obtained from other sterilization methods. The results of the maximum stress test and Young's modulus showed that gamma-irradiated and ethanol-treated scaffolds are more flexible than the EtO-treated and untreated scaffolds. The amount of sericin released, which was related to its collagen promoting effect, was highest from the gamma-irradiated scaffold. The results of this study indicate that gamma irradiation should have the greatest potential for sterilizing sericin scaffolds for skin tissue engineering.

  20. Evaluation of new technique of sterilization using biological indicator

    PubMed Central

    Sheth, Nomal Chintan; Rathod, Yogesh V.; Shenoi, Pratima R.; Shori, Deepa D.; Khode, Rajiv T.; Khadse, Amruta P.

    2017-01-01

    Background: A novel technique of sterilization of endodontic files is introduced in this article. Aims: Newly introduced sterilization unit, named “SteriFast” is compared with autoclave and glass bead sterilizer using biological indicator. Materials and Methods: Spore strips of Bacillus pumilus were cultured in nutrient broth. This cultured media was used to contaminate the experimental samples of endodontic files. These contaminated files were sterilized using three different techniques. The sterilized files were transferred into nutrient medium under aseptic condition. The results were observed after 24 h, 48 h, and 7 days. Results: The results showed that autoclave and new sterilization device (SteriFast) showed complete sterilization. The files sterilized using glass bead sterilizer showed bacterial growth (80%). Conclusions: Thus, it proves that autoclave and SteriFast are ideal techniques of sterilization of endodontic files. Glass bead sterilizer does not completely sterilize the files. The article also compares SteriFast and autoclave in other aspects such as its design, basic principle, advantages, and disadvantages. The article also describes features and design of SteriFast, used for all kind of small dental instruments. PMID:29386784

  1. The effect of a cannula milk sampling technique on the microbiological diagnosis of bovine mastitis.

    PubMed

    Friman, M; Hiitiö, H; Niemi, M; Holopainen, J; Pyörälä, S; Simojoki, H

    2017-08-01

    Two methods of collecting milk samples from mastitic bovine mammary quarters were compared. Samples were taken in a consistent order in which standard aseptic technique sampling was done first, followed by insertion of a sterile cannula through the teat canal and collection of a second sample. Microbiological results of those two sampling techniques were compared. Milk samples were analysed using multiplex real-time polymerase chain reaction (PCR). The cannula technique produced a reduced number of microbial species or groups of species per sample compared with conventional sampling. Staphylococcus spp. were the most common species identified and were detected more often during conventional sampling than with cannula sampling. Staphylococcus spp. identified in milk samples could also have originated from the teat canal without being present in the milk. The number of samples positive for Trueperella pyogenes or yeasts in the conventional samples was twice as high as in the cannula samples, indicating that the presence of Trueperella pyogenes and yeast species should not necessarily be interpreted as being the causative agents of bovine intra-mammary infections (IMI). Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Surface roughness of polyvinyl siloxane impression materials following chemical disinfection, autoclave and microwave sterilization.

    PubMed

    Al Kheraif, Abdulaziz Abdullah

    2013-05-01

    Autoclave sterilization and microwave sterilization has been suggested as the effective methods for the disinfection of elastomeric impressions, but subjecting elastomeric impressions to extreme temperature may have adverse effects on critical properties of the elastomers. To evaluate the effect of chemical disinfection as well as autoclave and microwave sterilization on the surface roughness of elastomeric impression materials. The surface roughness of five commercially available polyvinyl siloxane impression materials (Coltene President, Affinis Perfect impression, Aquasil, 3M ESPE Express and GC Exafast) were evaluated after subjecting them to chemical disinfection, autoclaving and microwave sterilization using a Talysurf Intra 50 instrument. Twenty specimens from each material were fabricated and divided into four equal groups, three experimental and one control (n=25). The differences in the mean surface roughness between the treatment groups were recorded and statistically analyzed. No statistically significant increase in the surface roughness was observed when the specimens were subjected to chemical disinfection and autoclave sterilization, increase in roughness and discoloration was observed in all the materials when specimens were subjected to microwave sterilization. Chemical disinfection did not have a significant effect but, since it is less effective, autoclave sterilization can be considered effective and autoclaving did not show any specimen discoloration as in microwave sterilization. Microwave sterilization may be considered when impressions are used to make diagnostic casts. A significant increase in surface roughness may produce rougher casts, resulting in rougher tissue surfaces for denture and cast restorations. Autoclave sterilization of vinyl polysiloxane elastomeric impressions for 5 minutes at 134°C at 20 psi may be considered an effective method over chemical disinfection and microwave sterilization, because chemical disinfection does not eliminate all disease-causing microorganisms and microwave sterilization leads to a rougher impression surface.

  3. Sterility method of pest control and its potential role in an integrated sea lamprey (Petromyzon marinus) control program

    USGS Publications Warehouse

    Hanson, Lee H.; Manion, Patrick J.

    1980-01-01

    The sterility method of pest control could be an effective tool in the sea lamprey (Petromyzon marinus) control program in the Great Lakes. Some of the requirements for its successful application have been met. A field study demonstrated that the release of male sea lampreys, sterilized by the injection of 100 mg/kg of P,P-bis(1-aziridinyl)-N-methylphosphinothioic amide (bisazir), will reduce the number of viable larvae produced. The actual reduction in reproductive success that occurred was directly related to the ratio of sterile to normal males in the population. The technique can be used in many ways in an integrated control program and has considerable potential for the more effective control of the sea lamprey. Eradication is a distinct possibility.Key words: sea lamprey, Petromyzon marinus; pest control, fish control, sterile-male technique, sterilization, chemosterilants, bisazir, Great Lakes

  4. Lessons from the recent rise in use of female sterilization in Malawi.

    PubMed

    Jacobstein, Roy

    2013-03-01

    Although female sterilization is the most widely used modern contraceptive method in the world, most family planning programs in Africa have had difficulty providing it. Malawi, however, despite daunting constraints, has made female sterilization widely and equitably accessible, thereby increasing method choice and helping its citizens better meet their reproductive intentions. Ten percent of currently married Malawian women of reproductive age rely on female sterilization for contraceptive protection, compared with less than 2 percent across Africa, and demand to limit births now exceeds demand to space births. Malawi's female sterilization prevalence surpasses that of some high-resource countries. Key service-delivery factors enabling this achievement include supportive policies, strong public-private partnerships, and mobile services delivered at no cost by dedicated providers. Challenges remain, but Malawi's achievement offers lessons for other countries with low availability of female sterilization and similar resource constraints. © 2013 The Population Council, Inc.

  5. Sterilization of instruments in solar ovens.

    PubMed

    Jørgensen, A F; Nøhr, K; Boisen, F; Nøhr, J

    2002-01-01

    The sterilization of instruments in rural health clinics in less developed countries is an increasing problem as chemical methods can no longer be recommended and fuel wood is becoming increasingly scarce. It seems obvious, therefore, to utilize solar energy for sterilization purposes. A solar oven was designed and manufactured using local materials and simple tools. It was tested by physical, chemical and microbiological methods and, after successful testing, installed in a rural clinic. The oven was able to generate temperatures above 180 degrees C. On days with direct sunlight the oven fulfilled the international recommendations for hot air sterilization. The chemical indicators, Browne's tubes type 3 and 5, also changed colour. It was difficult to reach the right value for the sterilization effect during months with a low sun position. A moveable oven, or two ovens, must be installed to solve this problem. The solar oven has proven to be a realistic method for the sterilization of instruments. The solar oven is easy to make and use. It saves fuel and can be used in most tropical areas.

  6. The effect of radiation on a variety of pharmaceuticals and materials containing polymers.

    PubMed

    Silindir, Mine; Ozer, Yekta

    2012-01-01

    The interaction of radiation, whether it has natural or artificial, electromagnetic or particle-type characterizations, with materials causes different effects depending on the dose and type of radiation and physicochemical properties of the material. In the medical field, understanding the effect of radiation on a variety of materials including pharmaceuticals, medical devices, polymers as biomaterials, and packaging is crucial. Although there are many kinds of sterilization methods, the use of radiation in sterilization has many advantages such as being a substantially less toxic, safer terminal sterilization method. Radiosterilization is sterilization with an ionizing radiation such as gamma rays or electron beam (e-beam), the latter being a newer but less-frequently used technique. However, the need for large facilities with proper radiation protections for personnel and the environment from the effects of radiation and radioactive wastes makes this procedure highly costly. The effects of radiation on materials, especially pharmaceuticals and polymer-containing medical devices, cause degradation or chemical changes. The effects of radiation on a variety of different materials is a growing research area that can create safer techniques that reduce radiation damage and increase cost-effectiveness in the future. Radiation can be used for positive purposes such as medical applications and the sterilization of pharmaceutical products, medical devices, and food and agricultural products as well as clinical applications such as diagnosis and/or therapy of a variety of diseases. The dose rate, time, type and emitted energy of the radiation are critical issues for determining its benefit/damage ratio. The sterilization of pharmaceuticals and medical devices that contain polymers can be achieved safely and effectively by irradiation. The sterilization of materials at the terminal phase-that is, in its final packaging materials-and its suitability to a variety of different kinds of packaging materials have brought additional value to radiosterilization. However, radiation sterilization is more expensive than the other sterilization methods that require large facilities. Although this method is safe in application, the effects of radiation on drugs and polymers must be evaluated by various analytical methods. In the nuclear chemistry and radiochemistry field, more effective and novel methods are being developed to decrease the harmful effects of radiation on materials.

  7. Sterilization and its consequences.

    PubMed

    Hendrix, N W; Chauhan, S P; Morrison, J C

    1999-12-01

    The purpose of this review is to analyze critically the two techniques of sterilization (bilateral tubal ligation [BTL] and vasectomy) so that a physician may provide informed consent about methods of sterilization. A MEDLINE search and extensive review of published literature dating back to 1966 was undertaken to compare preoperative counseling, operative procedures, postoperative complications, procedure-related costs, psychosocial consequences, and feasibility of reversal between BTL and a vasectomy. Compared with a vasectomy, BTL is 20 times more likely to have major complications, 10 to 37 times more likely to fail, and cost three times as much. Moreover, the procedure-related mortality, although rare, is 12 times higher with sterilization of the woman than of the man. Despite these advantages, 300,000 more BTLs were done in 1987 than vasectomies. In 1987, there were 976,000 sterilizations (65 percent BTLs and 35 percent vasectomies) with an overall cost of $1.8 billion. Over $260 million could have been saved if equal numbers of vasectomies and BTLs had been performed, or more than $800 million if 80 percent had been vasectomies, as was the case in 1971. The safest, most efficacious, and least expensive method of sterilization is vasectomy. For these reasons, physicians should recommend vasectomy when providing counseling on sterilization, despite the popularity of BTL. Obstetricians & Gynecologists, Family Physicians After completion of this article, the reader will be able to predict the failure rates and likelihood of successful reversal of tubal ligation and vasectomy; to recall the difference in cost between the two sterilization procedures, and to describe the short-term and long-term complications associated with each of the two methods of sterilization.

  8. "We never thought of a vasectomy": a qualitative study of men and women's counseling around sterilization.

    PubMed

    Shih, Grace; Dubé, Kate; Dehlendorf, Christine

    2013-09-01

    Sterilization is the most commonly used method of contraception in the United States; however, little is known about how providers counsel about these procedures or the information patients desire. In this study, we explore male and female experiences of sterilization counseling and their perspectives on ideal sterilization counseling. In-depth individual and group interviews were conducted with 37 heterosexual couples between the ages of 25 and 55 years. Each couple had reached their desired family size. Interviews were recorded and transcribed using NVivo software and analyzed using modified grounded theory. Men and women differed in their experiences of sterilization counseling. Women commonly received counseling on female sterilization but not vasectomy, while men rarely discussed either form of sterilization with their providers. Both men and women desired more information about sterilization. Contraceptive counseling of couples who have completed childbearing does not routinely include men or the option of vasectomy, despite the advantages of this method with respect to safety, efficacy and cost. Family planning and primary care providers have an important role in ensuring that couples are aware of all their options and can make an informed decision about their contraception. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Development of a sterilizing in-place application for a production machine using Vaporized Hydrogen Peroxide.

    PubMed

    Mau, T; Hartmann, V; Burmeister, J; Langguth, P; Häusler, H

    2004-01-01

    The use of steam in sterilization processes is limited by the implementation of heat-sensitive components inside the machines to be sterilized. Alternative low-temperature sterilization methods need to be found and their suitability evaluated. Vaporized Hydrogen Peroxide (VHP) technology was adapted for a production machine consisting of highly sensitive pressure sensors and thermo-labile air tube systems. This new kind of "cold" surface sterilization, known from the Barrier Isolator Technology, is based on the controlled release of hydrogen peroxide vapour into sealed enclosures. A mobile VHP generator was used to generate the hydrogen peroxide vapour. The unit was combined with the air conduction system of the production machine. Terminal vacuum pumps were installed to distribute the gas within the production machine and for its elimination. In order to control the sterilization process, different physical process monitors were incorporated. The validation of the process was based on biological indicators (Geobacillus stearothermophilus). The Limited Spearman Karber Method (LSKM) was used to statistically evaluate the sterilization process. The results show that it is possible to sterilize surfaces in a complex tube system with the use of gaseous hydrogen peroxide. A total microbial reduction of 6 log units was reached.

  10. The promotion of family planning by financial payments: the case of Bangladesh.

    PubMed

    Cleland, J; Mauldin, W P

    1991-01-01

    The government of Bangladesh and the World Bank commissioned a Compensation Payments Study, carried out in 1987, to assess the merits and demerits of payments for sterilizations to clients, medical personnel, and intermediaries who motivate and refer clients. The study conclusively shows that the decision of Bangladeshi men and women to undergo sterilization is a considered and voluntary act, taken in knowledge of the nature and implications of the procedure, and in knowledge of alternative methods of regulating fertility. There is a high degree of client satisfaction among those who have been sterilized, although among clients who had fewer than three children, 25 percent expressed regret that they had been sterilized. Money may be a contributing factor to the decision to become sterilized in a large majority of cases, but a dominant motive for only a very small minority. Payments to referrers have fostered a large number of unofficial, self-employed agents--particularly men who recruit vasectomy cases. These agents provide information about the procedures for being sterilized, particularly to the poor. They also concentrate on sterilizations to the exclusion of other methods, and are prone to minimize the disadvantages and exaggerate the attractions of sterilization.

  11. Molecular mechanism of plasma sterilization in solution with the reduced pH method: importance of permeation of HOO radicals into the cell membrane

    NASA Astrophysics Data System (ADS)

    Takai, Eisuke; Ikawa, Satoshi; Kitano, Katsuhisa; Kuwabara, Junpei; Shiraki, Kentaro

    2013-07-01

    Sterilization of certain infected areas of the human body surface is necessary for dental and surgical therapies. Because the blood is filled with body fluid, sterilization in solution is essential. In vitro solution sterilization has been successively carried out using a combination of low-temperature atmospheric-pressure plasma and the reduced pH method, where the solution is sufficiently acidic. Here, we show the molecular mechanism of such plasma sterilization in solution based on microbiology. Three kinds of bacteria were inactivated by plasma treatment under various pH conditions. The theoretical and experimental models revealed that the sterilization was characterized by the concentration of hydroperoxy radicals (HOO·), which were dependent on the pH value. Bacterial inactivation rates were proportional to the HOO· concentrations calculated by the theoretical model. To evaluate the penetration of radicals into the cell membrane, a bacterial model using dye-included micelles was used. Decolouration rates of the model were also in proportion with the calculated HOO· concentrations. These results indicate that the key species for plasma sterilization were hydroperoxy radicals. More importantly, the high permeation of hydroperoxy radicals into the cell membrane plays a key role for efficient bactericidal inactivation using the reduced pH method.

  12. Observations on female sterilization in Chile.

    PubMed

    Menanteau-Horta, D

    1982-01-01

    Prior to 1976, voluntary female sterilization was 1 of the regular family planning services offered in Chile. After that the Ministry of Public Health declared that it could not be considered a fertility regulation activity and could thus be performed only for health reasons. Between 1971-75, there was almost a 6-fold increase in the number of sterilizations performed at the Valdivia Regional Hospital, with a rise to 2400 procedures. Such an unprecedented increase in voluntary sterilization prompted this study. The results are based on a 1976 survey of women sterilized between 1971-75 at the Valdivia Regional Hospital. Personal interviews were conducted. The number of voluntary sterilizations there during the aforementioned period showed a sustained upward trend; the number of births increased only moderately during that time. The data on sterilization in the Valdivia area is compared to that collected by the Santiago study. Age, marital status, place of origin or residence, education, and religion were compared. Socioeconomic and occupational data were also examined. 9 of 10 women in Valdivia were from low-income families. This agrees closely with the Santiago data. About 1/4 of the women in both samples were employed outside the home. Also in both samples, about 1/2 of the spouses of sterilized women were blue collar workers; only 1/5 or less were white collar, and very few were professionals. About 52% in Valdivia and 45% in Santiago had borne 7 or more viable offspring. The average number of spontaneous abortions was also similar. A significantly higher percentage (P0.01) of Valdivia women used contraceptives. There are some general trends apparent in both groups as to the reasons for sterilization; most were prompted by difficult socioeconomic conditions. 37.9% of the Santiago women felt their families were complete and 27.3% of the other group cited the same reason. Other reasons were medical, failure of contraception, problems with spouse, and other. Medical and paramedical health services personnel played a significant role in patients' decision to request sterilization. Few women cited mass media as playing a part. Pomeroy and laparoscopic methods were the most popular methods used in Valdivia, 53.8% of the Santiago women were sterilized by the Pomeroy method and the others by Madlener or other methods. Postoperative results of sterilization are divided into clinical problems, postoperative attitude of spouse, and sexual relations. Results indicate that there are no substantial differences between the contraceptive behavior of Catholics and non-Catholics. There is an apparent need for more family planning education in Chile as is evidenced by complications of contraceptive method use. The postoperative consequences of sterilization suggest the need for research and analysis.

  13. Use of gamma radiation for preparation of nutrient culture media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Speranskaya, I.D.; Tumanyan, M.A.; Mironova, L.L.

    1977-01-01

    A technique was developed for sterilization of nutrient culture media using ..gamma..-radiation. For this purpose, dry preparations were exposed to 3 to 6 Mrad radiation, then dissolved in sterile distilled water. The quality of media and solutions thus obtained is as good as that of preparations sterilized by filtration. The advantage of the proposed sterilization method is that liquid media can be rapidly prepared and dry sterile media can be stored at room temperature for long periods of time.

  14. Thermoradiation inactivation of naturally occurring organisms in soil

    NASA Technical Reports Server (NTRS)

    Reynolds, M. C.; Lindell, K. F.; David, T. J.

    1973-01-01

    Samples of soil collected from Kennedy Space Center near spacecraft assembly facilities were found to contain microorganisms very resistant to conventional sterilization techniques. The inactivation behavior of the naturally occurring spores in soil was investigated using dry heat and ionizing radiation, first separately, then in combination. Dry heat inactivation rates of spores were determined for 105 and 125 C. Radiation inactivation rates were determined for dose rates of 660 and 76 krad/hr at 25 C. Simultaneous combinations of heat and radiation were then investigated at 105, 110, 115, 120, and 125 C. Combined treatment was found to be highly synergistic requiring greatly reduced radiation doses to accomplish sterilization.

  15. Surgical wound management made easier and more cost-effective.

    PubMed

    Akagi, Ichiro; Furukawa, Kiyonori; Miyashita, Masao; Kiyama, Teruo; Matsuda, Akihisa; Nomura, Tsutomu; Makino, Hiroshi; Hagiwara, Nobutoshi; Takahashi, Ken; Uchida, Eiji

    2012-07-01

    Evidence-based guidelines for the prevention of surgical site infection (SSI) have been published by the U.S. Centers for Disease Control and Prevention (CDC). According to these guidelines, a wound should usually be covered with a sterile dressing for 24 to 48 h when a surgical incision is closed primarily. However, it is not recommended that an incision be covered by a dressing beyond 48 h. In this study, patients were stratified into two groups for analysis: patients whose surgical wound was sterilized and whose gauze was changed once daily until postoperative day 7 (7POD; group A); and patients whose surgical wound was sterilized and whose gauze was changed once daily until 2POD (group B). We evaluated the incidence of SSI, nursing hours and cost implications. The results showed that there was no significant difference in SSI occurrence between the two groups (group A, 10% vs. group B, 7.3%). By contrast, the average nursing time differed by 2.8 min (group A, 3.8 min vs. group B, 0.9 min). The material costs per patient were also reduced by $14.70 (group A, $61.80 vs. group B, $47.10). In conclusion, we applied our knowledge of the evidence-based CDC guidelines to determine whether 48-h wound management can be made easier, more uniform and more cost-effective compared to conventional wound management. The results of the present study showed that surgical wound management methods can be more convenient and inexpensive.

  16. Laparoscopic Filshie clip sterilization and selective use of the methylene blue dye test.

    PubMed

    Karoshi, Mahantesh; Yoong, Wai

    2004-01-01

    In laparoscopic Filshie clip sterilization, difficulties may arise in identifying the length of the fallopian tube, with the possibility of failure of sterilization. This article describes a novel intraoperative method of demonstrating adequate tubal closure.

  17. Health technology assessment: Off-site sterilization

    PubMed Central

    Dehnavieh, Reza; Mirshekari, Nadia; Ghasemi, Sara; Goudarzi, Reza; Haghdoost, AliAkbar; Mehrolhassani, Mohammad Hossain; Moshkani, Zahra; Noori Hekmat, Somayeh

    2016-01-01

    Background: Every year millions of dollars are expended to equip and maintain the hospital sterilization centers, and our country is not an exception of this matter. According to this, it is important to use more effective technologies and methods in health system in order to reach more effectiveness and saving in costs. This study was conducted with the aim of evaluating the technology of regional sterilization centers. Methods: This study was done in four steps. At the first step, safety and effectiveness of technology was studied via systematic study of evidence. The next step was done to evaluate the economical aspect of off-site sterilization technology using gathered data from systematic review of the texts which were related to the technology and costs of off-site and in-site hospital sterilization. Third step was conducted to collect experiences of using technology in some selected hospitals around the world. And in the last step different aspects of acceptance and use of this technology in Iran were evaluated. Results: Review of the selected articles indicated that efficacy and effectiveness of this technology is Confirmed. The results also showed that using this method is not economical in Iran. Conclusion: According to the revealed evidences and also cost analysis, due to shortage of necessary substructures and economical aspect, installing the off-site sterilization health technology in hospitals is not possible currently. But this method can be used to provide sterilization services for clinics and outpatients centers. PMID:27390714

  18. Effect of a novel sterilization method on biomechanical properties of soft tissue allografts.

    PubMed

    Baldini, T; Caperton, K; Hawkins, M; McCarty, E

    2016-12-01

    Evaluate allograft tissue commonly used in soft tissue reconstruction to determine whether stiffness and strength were significantly altered after grafts were treated with different sterilization methods. Unprocessed, irradiated, and grafts treated with supercritical CO 2 were compared. Thirty-eight anterior or posterior tibialis tendons were obtained from a tissue bank (Allograft Innovations, Gainesville, FL). Group I was unprocessed, group II was sterilized with gamma irradiation (20-28 kGy), and group III was sterilized with supercritical CO 2 . The grafts were pretensioned to 89 N for 300 s. Specimens were then loaded from 50 to 300 N at 0.5 Hz for 250 cycles before being loaded to failure at 50 mm/min. Dependent variables were compared between sterilization groups with one-way ANOVA (P < 0.05) and equivalence trial. There was no significant difference in load to failure or failure stress among groups I, II, and III. Group III resulted in 27-36 % lower stiffness than group I and II. This difference was significant at 1, 10, 50, 100, and 250 cycles. There was no significant difference in stiffness between group I and group II. The two sterilization methods tested in this study do not affect allograft strength. The supercritical CO 2 sterilization method resulted in significantly lower stiffness than unprocessed and irradiated allografts. However, the stiffness and strength of all groups tested were greater than that of published values of the native intact anterior cruciate ligament (ACL). This study provides previously unpublished mechanical test data on a new sterilization technique that will assist surgeons to decide which allograft to use in ACL reconstruction surgery. III.

  19. Detection of fungi from rice black bug Paraeucosmetus pallicornis Dallas (Hemiptera: Lygaeidae) and inhibition with crude extract of Calatropis gigantea (Asclepiadaceae)

    NASA Astrophysics Data System (ADS)

    Sjam, S.; Surapati, U.; Adiwena; Syatri, A.; Dewi, V. S.; Rosmana, A.

    2018-05-01

    Rice black bug (P. palicornis) is one of the pests that attack the rice plants in the generative phase that causes the rice easily destroyed when milled and tasted bitter after cooking hence reduces the quality and quantity of rice. The bitter taste in rice may be due to the fungus associated with rice black bug. The aimed of this research was to detect the associated fungi with rice black bug P. pallicornis using some sterilization methods and inhibition with of leaf crude extract of C. gigatea. Detection of fungi from P. pallicornis was conducted using three sterilization methods and control (without sterilization) namely: (1) sterilization with aquades + alcohol 70% (5, 10, 15 and 20 times dipping) + aquades; (2) aquades + alcohol 70% (10 and 20 times dipping); (3) Aquades + alcohol 90 %+ NaCl 0.5 % +alcohol 90 % + aquades. Inhibition of fungi from P. pallicornis with crude extract of C. gigantea obtained by maceration method and then made some concentration to see the effect of its inhibition on the fungi associated with the P. pallicornis. The results showed that without sterilization, four microbe were obtained: Gliocladium sp., Aspergillus sp., black hyphae fungus and white hyphae fungus, sterilization method of Aquades + alcohol 70% with 5 times dipping in alcohol obtained Gliocladium sp., 10 and 20 times dipping found Aspergillus sp. and Gliocladium sp and 15 times dipping found Aspergillus sp. Sterilization with 10 and 20 times dipping in alcohol 70% then washing 2 times with aquades found Gliogladium sp. and Aspergillus sp. Sterilization with Aquades + alcohol 90 % + NaCl 0.5% + alcohol 90% + aquades found Gliocladium sp. Crude extract of C. gigantea had the potential to inhibit fungi Aspergillus sp. and Gliocladium sp. from rice black bug.

  20. Factors associated with sterilization among HIV-positive US women in an urban outpatient clinic.

    PubMed

    Raziano, V T; Smoots, A N; Haddad, L B; Wall, K M

    2017-05-01

    This cross-sectional study sought to determine factors associated with sterilization among HIV-positive US women. HIV-positive women aged 18-45 completed an Audio Computer Assisted Self Interview (ACASI) questionnaire. Chi-square tests and multivariable logistic regression evaluated factors associated with sterilization. The median age of the 187 participants was 37, the majority had at least a high school education, and 88% were African American. Nearly a quarter (22%) of women had undergone sterilization at an average age of 25; of these women, 71% cited their HIV-positive status as an important factor in deciding to have a tubal ligation, 22% expressed desire for future children, 32% reported sterilization regret, and 20% reported feeling pressure to undergo sterilization. In multivariable analysis, factors significantly associated with sterilization included non-African American race, no desire for future pregnancy, having heard of any birth control methods making it harder to get pregnant in the future, belief that women should take a break from hormonal methods every few years, and having had a child born with HIV. While almost a quarter of this HIV-positive group was sterilized, many during the height of the early HIV epidemic, a large proportion of sterilized women expressed sterilization regret. Counseling messages for sterilized HIV-positive women should be sensitive to the fact that women may have regret regarding a decision that, in some cases, may historically have been part of provider recommendations to prevent vertical transmission of HIV. Improved knowledge about contraceptive options such as the IUD and implant is needed among HIV-positive women.

  1. Sterilization Effect of Wet Oxygen Plasma in the Bubbling Method.

    PubMed

    Tamazawa, Kaoru; Shintani, Hideharu; Tamazawa, Yoshinori; Shimauchi, Hidetoshi

    2015-01-01

    A new low-temperature sterilization method to replace the ethylene oxide gas sterilization is needed. Strong bactericidal effects of OH and O2H radicals are well known. The purpose of this study was to evaluate the sterilization effect of wet oxygen ("O2+H2O") plasma in the bubbling method, confirming the effect of humidity. Sterility assurance was confirmed by using a biological indicator (Geobacillus stearothermophilus ATCC7953, Namsa, USA). One hundred and eight samples (10(5) spores/carrier) were divided into three groups of 36 in each for treatment with a different type of gas (O2, O2+H2O, Air+H2O). Plasma processing was conducted using a plasma ashing apparatus (13.56 MHz, PACK-3(®), Y. A. C., Japan) under various gas pressures (13, 25, 50 Pa) and gas flows (50, 100, 200 sccm). Fixed plasma treatment parameters were power at 150 W, temperature of 60 ℃, treatment time of 10 min. The samples after treatment were incubated in trypticase soy broth at 58 ℃ for 72 h. The negative culture rate in the "O2+H2O" group was significantly (Mantel-Haenszel procedure, p<0.001) higher than in the other gas groups. It is suggested that the significant sterilization effect of the "O2+H2O" group depends on the bubbling method which is the method of introducing vapor into the chamber. The bubbling method seems able to generate OH and O2H radicals in a stable way.

  2. ISO radiation sterilization standards

    NASA Astrophysics Data System (ADS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-06-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, "Radiation Sterilization Material Qualification" 2. ISO TR 13409-1996, "Sterilization of health care products — Radiation sterilization — Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches" 3. ISO Draft TR, "Sterilization of health care products — Radiation sterilization Selection of a sterilization dose for a single production batch" li]4. ISO Draft TR, "Sterilization of health care products — Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits."

  3. Implementing AORN recommended practices for sterilization.

    PubMed

    Graybill-D'Ercole, Patricia

    2013-05-01

    Any hospital or facility in which surgery and other invasive procedures are performed should have accommodations for cleaning, decontaminating, disinfecting, and sterilizing instruments, equipment, and other essential supplies that are used for patient procedures. Sterilization is essential to reducing or preventing the risk of surgical site infections. This is a collaborative process and should include all health care providers who handle these instruments, including perioperative nurses. The revised AORN "Recommended practices for sterilization," which became effective June 15, 2012, includes updates on sterilizing single-use items, inspecting critical items before sterilization, using low-temperature hydrogen peroxide vapor sterilization methods, and immediate use steam sterilization. This RP document is the first AORN document to be evidence rated and accepted for inclusion in the Agency for Healthcare Research and Quality National Guideline Clearinghouse. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  4. System And Method Of Applying Energetic Ions For Sterlization

    DOEpatents

    Schmidt, John A.

    2002-06-11

    A method of sterilization of a container is provided whereby a cold plasma is caused to be disposed near a surface to be sterilized, and the cold plasma is then subjected to a pulsed voltage differential for producing energized ions in the plasma. Those energized ions then operate to achieve spore destruction on the surface to be sterilized. Further, a system for sterilization of a container which includes a conductive or non-conductive container, a cold plasma in proximity to the container, and a high voltage source for delivering a pulsed voltage differential between an electrode and the container and across the cold plasma, is provided.

  5. Influence of gamma radiation onto polymeric matrix with papain

    NASA Astrophysics Data System (ADS)

    Zulli, Gislaine; Lopes, Patrícia Santos; Velasco, Maria Valéria Robles; Alcântara, Mara Tânia Silva; Rogero, Sizue Ota; Lugao, Ademar Benévolo; Mathor, Monica Beatriz

    2010-03-01

    Papain is a proteolytic enzyme that has been widely used as debridement agent for scars and wound healing treatment. However, papain presents low stability, which limits its use to extemporaneous or short shelf-life formulations. The purpose of this study was to entrap papain into a polymeric matrix in order to obtain a drug delivery system that could be used as medical device. Since these systems must be sterile, gamma radiation is an interesting option and presents advantages in relation to conventional agents: no radioactive residues are formed; the product can be sterilized inside the final packaging and has an excellent reliability. The normative reference for the establishment of the sterilizing dose determines 25 kGy as the inactivation dose for viable microorganisms. A silicone dispersion was selected to prepare membranes containing 2% (w/w) papain. Irradiated and non-irradiated membranes were simultaneously assessed in order to verify whether gamma radiation interferes with the drug-releasing profile. Results showed that irradiation does not affect significantly papain release and its activity. Therefore papain shows radioresistance in the irradiation conditions applied. In conclusion, gamma radiation can be easily used as sterilizing agent without affecting the papain release profile and its activity onto the biocompatible device is studied.

  6. Degradation of pharmaceuticals in non-sterile urban wastewater by Trametes versicolor in a fluidized bed bioreactor.

    PubMed

    Cruz-Morató, Carles; Ferrando-Climent, Laura; Rodriguez-Mozaz, Sara; Barceló, Damià; Marco-Urrea, Ernest; Vicent, Teresa; Sarrà, Montserrat

    2013-09-15

    The constant detection of pharmaceuticals (PhACs) in the environment demonstrates the inefficiency of conventional wastewater treatment plants to completely remove them from wastewaters. So far, many studies have shown the feasibility of using white rot fungi to remove these contaminants. However, none of them have studied the degradation of several PhACs in real urban wastewater under non-sterile conditions, where mixtures of contaminants presents at low concentrations (ng L(-1) to μg L(-1)) as well as other active microorganisms are present. In this work, a batch fluidized bed bioreactor was used to study, for the first time, the degradation of PhACs present in urban wastewaters at their pre-existent concentrations under non-sterile conditions. Glucose and ammonium tartrate were continuously supplied as carbon and nitrogen source, respectively, and pH was maintained at 4.5. Complete removal of 7 out of the 10 initially detected PhACs was achieved in non-sterile treatment, while only 2 were partially removed and 1 of the PhACs analyzed increased its concentration. In addition, Microtox test showed an important reduction of toxicity in the wastewater after the treatment. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Comparison of two radio-frequency plasma sterilization processes using microspot evaluation of microbial inactivation.

    PubMed

    Lassen, Klaus S; Johansen, Jens E; Grün, Reinar

    2006-07-01

    In this study, we evaluated gas plasma surface sterilization methods in a specific sterilizer. We have introduced a new monitoring method using 0.4 microm pore size membranes, which in this study gave the information corresponding to 3000 exposed biological indicators per treatment cycle. This enabled us to compare the fraction of inoculates that showed no growth after exposure for 30 different locations in the chamber, and hereby identify weak and strong spots in the chamber with regard to sporicidal effect. Membranes were also used to expose a broad spectrum of soil bacteria for plasma treatment at four different conditions. The organisms were identified using PCR and sequencing. The test showed that Bacillus stearothermophilus spores were inactivated at the slowest rate among the tested microorganisms. Further alpha-proteobacteria (Gram negative) seemed more sensitive than the rest of the tested organisms. The microspot evaluation approach has been a most useful tool in the assessment of sterilization performance in sterilizers that do not have clear measurable parameters related to the sterilization.

  8. The research of using Co-60 γ ray to sterilize different mediums for edible fungus

    NASA Astrophysics Data System (ADS)

    Guozhu, Li; Zhenqian, Guan; Hengshou, Zhao

    1993-10-01

    The present experiment has been carried out by using different dosage of Co—60 γ ray for radiation sterilization of five kinds of cultural materials of edible fungus, The results indicated that sterilization dosage of sawdust is 22 kGy. that of cotton—seed shell and the rest are 26 kGy. We conclude that using Co-60 γ ray to sterilize the cultura 1 materials of edible fungus is a secure and saving labor and energy new method which could sterilize thoroughly.

  9. Influence of ∼7 keV sterile neutrino dark matter on the process of reionization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudakovskyi, Anton; Iakubovskyi, Dmytro, E-mail: rudakovskyi@gmail.com, E-mail: iakubovskyi@nbi.ku.dk

    2016-06-01

    Recent reports of a weak unidentified emission line at ∼3.5 keV found in spectra of several matter-dominated objects may give a clue to resolve the long-standing problem of dark matter. One of the best physically motivated particle candidate able to produce such an extra line is sterile neutrino with the mass of ∼7 keV . Previous works show that sterile neutrino dark matter with parameters consistent with the new line measurement modestly affects structure formation compared to conventional cold dark matter scenario. In this work, we concentrate for the first time on contribution of the sterile neutrino dark matter ablemore » to produce the observed line at ∼3.5 keV, to the process of reionization. By incorporating dark matter power spectra for ∼7 keV sterile neutrinos into extended semi-analytical 'bubble' model of reionization we obtain that such sterile neutrino dark matter would produce significantly sharper reionization compared to widely used cold dark matter models, impossible to 'imitate' within the cold dark matter scenario under any reasonable choice of our model parameters, and would have a clear tendency of lowering both the redshift of reionization and the electron scattering optical depth (although the difference is still below the existing model uncertainties). Further dedicated studies of reionization (such as 21 cm measurements or studies of kinetic Sunyaev-Zeldovich effect) will thus be essential for reconstruction of particle candidate responsible the ∼3.5 keV line.« less

  10. Device and Container for Reheating and Sterilization

    NASA Technical Reports Server (NTRS)

    Sastry, Sudhir K.; Heskitt, Brian F.; Jun, Soojin; Marcy, Joseph E.; Mahna, Ritesh

    2012-01-01

    Long-duration space missions require the development of improved foods and novel packages that do not represent a significant disposal issue. In addition, it would also be desirable if rapid heating technologies could be used on Earth as well, to improve food quality during a sterilization process. For this purpose, a package equipped with electrodes was developed that will enable rapid reheating of contents via ohmic heating to serving temperature during space vehicle transit. Further, the package is designed with a resealing feature, which enables the package, once used, to contain and sterilize waste, including human waste for storage prior to jettison during a long-duration mission. Ohmic heating is a technology that has been investigated on and off for over a century. Literature indicates that foods processed by ohmic heating are of superior quality to their conventionally processed counterparts. This is due to the speed and uniformity of ohmic heating, which minimizes exposure of sensitive materials to high temperatures. In principle, the material may be heated rapidly to sterilization conditions, cooled rapidly, and stored. The ohmic heating device herein is incorporated within a package. While this by itself is not novel, a reusable feature also was developed with the intent that waste may be stored and re-sterilized within the packages. These would then serve a useful function after their use in food processing and storage. The enclosure should be designed to minimize mass (and for NASA's purposes, Equivalent System Mass, or ESM), while enabling the sterilization function. It should also be electrically insulating. For this reason, Ultem high-strength, machinable electrical insulator was used.

  11. Contraceptive prevalence, reproductive health and our common future. The C. Donald Christian Memorial Lecture.

    PubMed

    Diczfalusy, E

    1993-05-01

    Worldwide, female sterilization is the most common contraceptive method, followed by IUDs and oral contraceptives. As unwanted pregnancy for women in developing countries can mean life or death, which may explain why modern contraceptive methods with low failure rates (e.g., sterilization, IUDs. and hormonal methods) predominate in developing countries. Conventional methods with relatively high failure rates (e.g., natural family planning, barrier methods, and withdrawal) predominate in developed countries. Developing-country governments first supported family planning programs for demographic reasons. They now embrace them because they save the lives of women and children. The four fundamental pillars of reproductive health policy are family planning, maternal care, infant and child care, and control of sexually transmitted diseases (STDs). Indicators of reproductive health include, rates of maternal mortality and morbidity; induced abortion; infertility; perinatal, infant, and child mortality; and STDs (including AIDS). Governments in the poorest countries invest only US$5 per capita for health, compared to US$400 per capita for developed countries. If the poorest countries increased that $5 figure by just $2 per capita, they could immunize all children, eradicate polio, and provide the drugs to cure the most common diseases. Further, if humans were to use resources more reasonably, we could greatly decrease the number of people living in poverty. Three UN population projections show that the population will continue to grow well within the next century. With strong commitment from governments and individuals, we can increase contraceptive use and reduce total fertility rates. Barriers to achieving those goals are few funds allocated to family planning methods and services; politicians; religious and community leaders; culture; low women's status; limited accessibility to information, methods, and quality services; and limited contraceptive choice.

  12. Characteristics of Surface Sterilization using ECR Plasma

    NASA Astrophysics Data System (ADS)

    Yonesu, Akira; Hara, Kazufumi; Nishikawa, Tatsuya; Hayashi, Nobuya

    2015-09-01

    Plasma sterilization techniques have superior characteristics such as a short treatment times, non-toxicity and low thermal damages on the sterilized materials. In plasma sterilization, microorganisms can be sterilized by active radicals, energetic charged particles, and vacuum UV radiation. The influence of each factor depends on the plasma operating parameters. Microwave discharges under the electron cyclotron resonance (ECR) condition produce higher electron temperature and density plasma as compared with other plasma generation techniques. In the present study, characteristics of surface sterilization using ECR plasma have been investigated.The experiment was performed in the vacuum chamber which contains a magnet holder. A pair of rectangular Sm-Co permanent magnets is aligned parallel to each other within the magnet holder. The region of the magnetic field for ECR exists near the magnet holder surface. When the microwave is introduced into the vacuum chamber, a ECR plasma is produced around surface of the magnet holder. High energy electrons and oxygen radicals were observed at ECR zone by electric probe method and optical spectroscopic method. Biological indicators (B.I.) having spore of 106 was sterilized in 2min for oxygen discharge. The temperature of the B.I. installation position was about 55°. The sterilization was achieved by the effect of oxygen radicals and high energy electrons.

  13. [Cost management: the implementation of the activity-based costing method in sterile processing department].

    PubMed

    Jericó, Marli de Carvalho; Castilho, Valéria

    2010-09-01

    This exploratory case study was performed aiming at implementing the Activity-based Costing (ABC) method in a sterile processing department (SPD) of a major teaching hospital. Data collection was performed throughout 2006. Documentary research techniques and non participant closed observation were used. The ABC implementation allowed for learning the activity-based costing of both the chemical and physical disinfection cycle/load: (dollar 9.95) and (dollar 12.63), respectively; as well as the cost for sterilization by steam under pressure (autoclave) (dollar 31.37) and low temperature steam and gaseous formaldehyde sterilization (LTSF) (dollar 255.28). The information provided by the ABC method has optimized the overall understanding of the cost driver process and provided the foundation for assessing performance and improvement in the SPD processes.

  14. Splint sterilization--a potential registration hazard in computer-assisted surgery.

    PubMed

    Figl, Michael; Weber, Christoph; Assadian, Ojan; Toma, Cyril D; Traxler, Hannes; Seemann, Rudolf; Guevara-Rojas, Godoberto; Pöschl, Wolfgang P; Ewers, Rolf; Schicho, Kurt

    2012-04-01

    Registration of preoperative targeting information for the intraoperative situation is a crucial step in computer-assisted surgical interventions. Point-to-point registration using acrylic splints is among the most frequently used procedures. There are, however, no generally accepted recommendations for sterilization of the splint. An appropriate method for the thermolabile splint would be hydrogen peroxide-based plasma sterilization. This study evaluated the potential deformation of the splint undergoing such sterilization. Deformation was quantified using image-processing methods applied to computed tomographic (CT) volumes before and after sterilization. An acrylic navigation splint was used as the study object. Eight metallic markers placed in the splint were used for registration. Six steel spheres in the mouthpiece were used as targets. Two CT volumes of the splint were acquired before and after 5 sterilization cycles using a hydrogen peroxide sterilizer. Point-to-point registration was applied, and fiducial and target registration errors were computed. Surfaces were extracted from CT scans and Hausdorff distances were derived. Effectiveness of sterilization was determined using Geobacillus stearothermophilus. Fiducial-based registration of CT scans before and after sterilization resulted in a mean fiducial registration error of 0.74 mm; the target registration error in the mouthpiece was 0.15 mm. The Hausdorff distance, describing the maximal deformation of the splint, was 2.51 mm. Ninety percent of point-surface distances were shorter than 0.61 mm, and 95% were shorter than 0.73 mm. No bacterial growth was found after the sterilization process. Hydrogen peroxide-based low-temperature plasma sterilization does not deform the splint, which is the base for correct computer-navigated surgery. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Evaluation of different sterilization and disinfection methods on commercially made preformed crowns.

    PubMed

    Yilmaz, Y; Guler, C

    2008-12-01

    The aim of this study was to evaluate the changes caused by different sterilization or disinfection methods on the vestibular surface of four commercially made preformed crowns using stereomicroscopy and scanning electron microscopy (SEM). Preformed crowns (NuSmile Primary Anterior Crown (NSC), Kinder Krowns (KK), Pedo Pearls (PP) and polycarbonate crowns (PC)) were sterilized and/or disinfected by one of the following techniques: no sterilization or disinfection (G1 control group); steam autoclaving at 134 degrees C (30 psi) for 4 min (G2); steam autoclaving at 134 degrees C (30 psi) for 12 min (G3); steam autoclaving at 121 degrees C (15 psi) for 30 min (G4); and ultrasonication in a bath containing 4% Lysetol AF for 5 min at room temperature (chemical disinfection) (G5). Scanning electron micrographs of the crowns were taken before and after their sterilization or disinfection. The changes on the vestibular surface were then scored for the presence or absence of crazing, contour alteration, fracturing, and vestibular surface changes. The data were analyzed statistically using the chi-square test. No changes were observed before and after sterilization or disinfection in the stereomicroscopic evaluation of the vestibular surface of the crowns. However, all methods in which steam autoclaving was used to sterilize the crowns caused significant (P < 0.05) crazing and contour alterations of the vestibular surface of the crowns when they were examined by SEM. Chemical disinfection using an aldehyde-free disinfectant is the preferred method of disinfection for crowns that have been used previously in other dental patients.

  16. Differences in the Access to Sterilization between Women Living and Not Living with HIV: Results from the GENIH Study, Brazil

    PubMed Central

    Cabral, Cristiane da Silva; do Lago, Tania di Giacomo; Pinho, Adriana de Araujo

    2016-01-01

    Background In many countries, young women of reproductive age have been especially affected by the HIV epidemic, which have fostered research to better understand how HIV infection influences and shapes women´s fertility and reproductive and sexual decisions. In Brazil, few studies have focused on the impact of the HIV epidemic on contraceptive choices among women living with HIV (WLHIV). Objective This study evaluates the impact HIV infection may have in the access to female sterilization in Brazil, using a time-to-event analysis. Methods A cross-sectional quantitative study (GENIH study) was conducted between February 2013 and April 2014 in the city of São Paulo, comparing two probabilistic samples of 975 WLHIV and 1,003 women not living with HIV (WNLHIV) aged 18 to 49. Sexual and reproductive data was collected retrospectively in order to reconstruct women's reproductive trajectories. Given the objectives of this study, the analysis was restricted to women with parity one or more and, in case of WLHIV, to those sterilized after HIV diagnosis and not infected through vertical transmission. The final sample analysis included 683 WNLHIV and 690 WLHIV. A series of multivariable-adjusted Cox models estimated the probability of being sterilized after HIV diagnosis, compared with WNLHIV. Models were adjusted for schooling, race/color, and stratified by parity at last delivery (1–2, 3+). Hazard ratios were calculated for female sterilization, and separately for interval and postpartum procedures (performed in conjunction with caesarean section or immediately after vaginal delivery). Additionally, information regarding unmet demand for female sterilization was also explored. Findings No statistical difference in the overall risk of sterilization between WLHIV and WNLHIV in the two parity-related groups is observed: HR = 0.88 (0.54–1.43) and 0.94 (0.69–1.29), respectively, among women with 1–2 children and those with three and more. However, significant differences regarding the impact of HIV infection at sterilization are observed depending on the timing and the type of sterilization procedure. The probability of obtaining an interval sterilization is significantly lower for WLHIV compared to those not living with HIV. The reverse occurs regarding postpartum sterilization. Although sterilization is mainly performed in conjunction with caesarean section in Brazil, it is evident that caesarean sections are not the sole factor increasing the risk of sterilization among WLHIV. Conclusion The results indicate barriers in the access to services offering interval sterilization for WLHIV and certain facilitation in obtaining the procedure in conjunction with caesarean section. Health policy makers at local and national levels should promote institutional changes in order to facilitate access to interval sterilization and to confront the sensitive discussion of WLHIV’s eligibility for postpartum sterilization. It is also urgent to increase access to a wider range of contraceptive methods for WLHIV and promote dual method protection strategies. Moreover, since condom use may decrease in the future in the context of the preventive effect of antiretroviral therapy, promoting dual methods will expand the choices regarding the reproductive rights of women living with HIV. PMID:27812146

  17. Power Ultrasound to Process Dairy Products

    NASA Astrophysics Data System (ADS)

    Bermúdez-Aguirre, Daniela; Barbosa-Cánovas, Gustavo V.

    Conventional methods of pasteurizing milk involve the use of heat regardless of treatment (batch, high temperature short time - HTST or ultra high temperature - UHT sterilization), and the quality of the milk is affected because of the use of high temperatures. Consequences of thermal treatment are a decrease in nutritional properties through the destruction of vitamins or denaturation of proteins, and sometimes the flavor of milk is undesirably changed. These changes are produced at the same time that the goal of the pasteurization process is achieved, which is to have a microbiological safe product, free of pathogenic bacteria, and to reduce the load of deteriorative microorganisms and enzymes, resulting in a product with a longer storage life.

  18. Surgical bedside master console for neurosurgical robotic system.

    PubMed

    Arata, Jumpei; Kenmotsu, Hajime; Takagi, Motoki; Hori, Tatsuya; Miyagi, Takahiro; Fujimoto, Hideo; Kajita, Yasukazu; Hayashi, Yuichiro; Chinzei, Kiyoyuki; Hashizume, Makoto

    2013-01-01

    We are currently developing a neurosurgical robotic system that facilitates access to residual tumors and improves brain tumor removal surgical outcomes. The system combines conventional and robotic surgery allowing for a quick conversion between the procedures. This concept requires a new master console that can be positioned at the surgical bedside and be sterilized. The master console was developed using new technologies, such as a parallel mechanism and pneumatic sensors. The parallel mechanism is a purely passive 5-DOF (degrees of freedom) joystick based on the author's haptic research. The parallel mechanism enables motion input of conventional brain tumor removal surgery with a compact, intuitive interface that can be used in a conventional surgical environment. In addition, the pneumatic sensors implemented on the mechanism provide an intuitive interface and electrically isolate the tool parts from the mechanism so they can be easily sterilized. The 5-DOF parallel mechanism is compact (17 cm width, 19cm depth, and 15cm height), provides a 505,050 mm and 90° workspace and is highly backdrivable (0.27N of resistance force representing the surgical motion). The evaluation tests revealed that the pneumatic sensors can properly measure the suction strength, grasping force, and hand contact. In addition, an installability test showed that the master console can be used in a conventional surgical environment. The proposed master console design was shown to be feasible for operative neurosurgery based on comprehensive testing. This master console is currently being tested for master-slave control with a surgical robotic system.

  19. The effect of endoscopic sterilization on reproductive behavior and pair bond maintenance of feral pigeons (Columba livia).

    PubMed

    Heiderich, E; Failing, K; Lierz, M; Schildger, B

    2016-01-01

    Problems related to feral pigeons (Columba livia) in cities mainly result from their large numbers due to uncontrolled population growth. The aim of this study was to evaluate whether endoscopic guided sterilization affects the reproductive behavior of feral pigeons under experimental conditions, with the intention of assessing this technique as a potential method for feral pigeon population control. Five groups of four pairs of feral pigeons each were studied from 8 weeks before, to 7 weeks after sterilization. Both the male and female of the first pair of each group were sterilized, in the second pair only the female and in the third pair only the male was sterilized. The fourth pair acted as a control. All eggs laid were candled to assess fertility. Surgical sterilization had minimal effects on behavior and therefore seems not to have impact on possible field application for population control. All pairs maintained their pair bonds and continued to defend their nesting sites against other pigeons. Only one female copulated with a foreign fertile male while her primary partner was debilitated due to surgery, but returned to him as soon as he recovered. All eggs laid more than 5 days after male sterilization were infertile, whereas all control pairs had fertile eggs. Only one fertile clutch was produced, 5 days after the male's sterilization. Therefore it is assumed that males remain fertile for a limited period of time. Endoscopic sterilization seems to be a promising method for field control of feral pigeon populations and sterilization of the male only seems sufficient.

  20. Product sterilization. Why industry uses radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sparks, B.J.

    1984-09-01

    Industry uses gamma radiation sterilization because of its superior reliability, safety, and cost savings over the EO fumigation method. EO has many processing variables and is toxic and expensive. The Environmental Protection Agency has recently declared EO to be both mutagenic and carcinogenic. The residual EO in hospital products has been reported to adversely affect hospital workers. Unlike EO fumigation, radiation sterilization imparts no toxic residuals. The coloration and embrittlement problems experienced earlier with some products sterilized by gamma radiation are being overcome with the introduction of new manufacturing materials and lower radiation dosages. Other benefits of radiation sterilization includemore » the option of sterilizing some materials that could not otherwise be sterilized and using new types of packaging to better protect the products and increase shelf-life. The emphasis now being placed on cost containment for health care products will be another significant part of the answer to why industry uses gamma radiation sterilization.« less

  1. Research progress on the brewing techniques of new-type rice wine.

    PubMed

    Jiao, Aiquan; Xu, Xueming; Jin, Zhengyu

    2017-01-15

    As a traditional alcoholic beverage, Chinese rice wine (CRW) with high nutritional value and unique flavor has been popular in China for thousands of years. Although traditional production methods had been used without change for centuries, numerous technological innovations in the last decades have greatly impacted on the CRW industry. However, reviews related to the technology research progress in this field are relatively few. This article aimed at providing a brief summary of the recent developments in the new brewing technologies for making CRW. Based on the comparison between the conventional methods and the innovative technologies of CRW brewing, three principal aspects were summarized and sorted, including the innovation of raw material pretreatment, the optimization of fermentation and the reform of sterilization technology. Furthermore, by comparing the advantages and disadvantages of these methods, various issues are addressed related to the prospect of the CRW industry. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. "Forgotten" Chapters in the History of Transcervical Sterilization: Carl Clauberg and Hans-Joachim Lindemann.

    PubMed

    Hildebrandt, Sabine; Benedict, Susan; Miller, Erin; Gaffney, Michael; Grodin, Michael A

    2017-07-01

    Transcervical sterilization is a non-surgical method of permanent female sterilization that is widely used and critically discussed. A review of the historiography of the method reveals that instances of its coercive use are not included in the historical account. This study offers a reexamination of the work of Carl Clauberg and Hans-Joachim Lindemann, to more deeply contextualize within the framework of current usage the coercive use of transcervical sterilization during the Third Reich and in postwar Germany. This inquiry is based on postwar criminal trial records on Clauberg, and on archival documents detailing Lindemann's activities in 1979. A comparative analysis examines arguments by medical historian Karl-Heinz Roth, and identifies shared characteristics and differences between Clauberg and Lindemann, their methods and scientific connections. The results demonstrate that the technique of transcervical sterilization has an abusive potential that may be explained as a function of the person of the physician, of the scientific method itself, and of societal and political influences. The analysis supports the argument that insights from the cases of Clauberg and Lindemann are transferrable geographically and over time, and have the potential to inform current medical practice, such as transcervical sterilization with the Essure device, whose historiographic exploration remains a desideratum. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Effects of steam sterilization on thermogelling chitosan-based gels.

    PubMed

    Jarry, C; Chaput, C; Chenite, A; Renaud, M A; Buschmann, M; Leroux, J C

    2001-01-01

    A new thermogelling chitosan-glycerophosphate system has been recently proposed for biomedical applications such as drug and cell delivery. The objectives of this work were to characterize the effect of steam sterilization on the in vitro and in vivo end performances of the gel and to develop a filtration-based method to assess its sterility. Autoclaving 2% (w/v) chitosan solutions for as short as 10 min resulted in a 30% decrease in molecular weight, 3-5-fold decrease in dynamic viscosity, and substantial loss of mechanical properties of the resulting gel. However, sterilization did not impair the ability of the system to form a gel at 37 degrees C. The antimicrobial activity of chitosan against several microorganisms was evaluated after inoculation of chitosan solutions and removal of the cells by filtration. It was found that, although chitosan was bacteriostatic against the heat sterilization bioindicator Bacillus stearothermophilus, the bacteria could rapidly grow after separation from the chitosan solution by filtration. This indicated that B. stearothermophilus is an adequate strain to validate a heat sterilization method on chitosan preparations, and accordingly this strain was used to assess the sterility of chitosan solution following a 10 min autoclaving time. Copyright 2001 John Wiley & Sons, Inc.

  4. Gas plasma sterilization of microorganisms and mechanisms of action

    PubMed Central

    SHINTANI, HIDEHARU; SAKUDO, AKIKAZU; BURKE, PETER; McDONNELL, GERALD

    2010-01-01

    The use of true gas plasmas for the inactivation of microorganisms is an area of dynamic research. Many types of gases are used as a source of plasma, and different plasma production methods have been applied. The antimicrobial mechanisms of oxygen-based gas plasmas may be due to an etching effect on microbial structures, particularly bacterial endospores resulting in shrinkage. By contrast, the definite mechanisms of actions of other gas plasma sources, such as N2, He, Ne, Ar and Xe gases, have not been clearly defined and indeed may be distinct. The speculated mechanisms of these gas plasmas involve the direct attack of metastable (excited molecular), UV and/or VUV to microbial structures, specifically the inner membrane and DNA in the core of bacterial endospores. According to this speculation, sterilized spore figures would remain unchanged. However, these mechanisms remain to be clarified. Future perspectives on the use of gas plasma for sterilization are of interest, as it is possible that appropriate sterility assurance levels can be obtained in parallel with material and functional compatibility. Traditional sterilization methods are often limited in these requirements. Therefore, gas plasma sterilization may prove to be an appropriate alternative sterilization procedure. PMID:22993596

  5. Implementing AORN recommended practices for sterile technique.

    PubMed

    Kennedy, Lynne

    2013-07-01

    Using sterile technique helps prevent the surgical environment from becoming contaminated and thus can help reduce the incidence of surgical site infection. The AORN "Recommended practices for sterile technique" provides guidance for setting up, maintaining, and monitoring a sterile field. Topics include the use of surgical attire and personal protective equipment; appropriate selection and evaluation of surgical gowns, gloves, and drape products for each procedure; use of sterile technique to don sterile gowns and gloves; appropriate methods for establishing and monitoring a sterile field; and techniques to ensure that items such as surgical instruments that may be contaminated are not used. Breaks in sterile technique should be corrected immediately unless the actions necessary would endanger the patient. If remedial actions must be delayed, they should be undertaken as soon as possible. Adhering to best practices for sterile technique requires remaining up to date with new approaches and incorporating these into quality initiatives. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  6. Sterilization failures in Singapore: an examination of ligation techniques and failure rates.

    PubMed

    Cheng, M C; Wong, Y M; Rochat, R W; Ratnam, S S

    1977-04-01

    The University Department of Obstetrics and Gynecology, Kandang Kerbau Hospital in Singapore, initiated a study in early 1974 of failure rates for various methods of sterilization and the factors responsible for the failures. During the period January 1974 to March 1976, 51 cases of first pregnancy following ligation were discovered. Cumulative failure rates at 24 months were 0.34 per 100 women for abdominal sterilization, 1.67 for culdoscopic, 3.12 for vaginal, and 4.49 for laparoscopic procedures. Findings for 35 patients who underwent religation showed that recanalization and the establishment of a fistulous opening caused the majority of failures. Clearly, more effective methods of tubal occlusion in sterilization are needed.

  7. IPPF re-affirms its policy on sterilization: a free, informed and unpressured choice.

    PubMed

    1977-01-01

    The IPPF has re-affirmed its policy on sterilization that individuals have the right to voluntarily choose a contraceptive method. A sterilization acceptor should understand all the implications and that the procedure should be considered irreversible, although medical techniques should be used to give the greatest chance of reversibility. An individual should know of alternative contraceptive methods and the risks and benefits involved with each. Incentives for family planning programs should ensure that benefits be in addition to the benefits and services which are entitled to everyone; likewise, any disincentives should not conflict with basic human rights. Family planning education should promote informed decisions on contraceptive use including sterilization procedures.

  8. Experiences of coercion to sterilize and forced sterilization among women living with HIV in Latin America

    PubMed Central

    Kendall, Tamil; Albert, Claire

    2015-01-01

    Introduction Forced and coerced sterilization is an internationally recognized human rights violation reported by women living with HIV (WLHIV) around the globe. Forced sterilization occurs when a person is sterilized without her knowledge or informed consent. Coerced sterilization occurs when misinformation, intimidation tactics, financial incentives or access to health services or employment are used to compel individuals to accept the procedure. Methods Drawing on community-based research with 285 WLHIV from four Latin American countries (El Salvador, Honduras, Mexico and Nicaragua), we conduct thematic qualitative analysis of reports of how and when healthcare providers pressured women to sterilize and multivariate logistic regression to assess whether social and economic characteristics and fertility history were associated with pressure to sterilize. Results A quarter (23%) of the participant WLHIV experienced pressure to sterilize post-diagnosis. WLHIV who had a pregnancy during which they (and their healthcare providers) knew their HIV diagnosis were almost six times more likely to experience coercive or forced sterilization than WLHIV who did not have a pregnancy with a known diagnosis (OR 5.66 CI 95% 2.35–13.58 p≤0.001). WLHIV reported that healthcare providers told them that living with HIV annulled their right to choose the number and spacing of their children and their contraceptive method, employed misinformation about the consequences of a subsequent pregnancy for women's and children's health, and denied medical services needed to prevent vertical (mother-to-child) HIV transmission to coerce women into accepting sterilization. Forced sterilization was practiced during caesarean delivery. Conclusions The experiences of WLHIV indicate that HIV-related stigma and discrimination by healthcare providers is a primary driver of coercive and forced sterilization. WLHIV are particularly vulnerable when seeking maternal health services. Health worker training on HIV and reproductive rights, improving counselling on HIV and sexual and reproductive health for WLHIV, providing State mechanisms to investigate and sanction coercive and forced sterilization, and strengthening civil society to increase WLHIV's capacity to resist coercion to sterilize can contribute to preventing coercive and forced sterilization. Improved access to judicial and non-judicial mechanisms to procure justice for women who have experienced reproductive rights violations is also needed. PMID:25808633

  9. Factors Related to Intention to Undergo Female Sterilization Among Married Women in Rural Kathmandu, Nepal

    PubMed Central

    Nanthamongkolchai, Sutham; Pitikultang, Supachai

    2016-01-01

    Background: Sterilization is most widely used fertility regulation method in Nepal. However, prevalence of uptake of female sterilization in central hilly region is less than the national average. The objective of the study was to explore the number and factors related to intention of married women to undergo female sterilization in rural Kathmandu which lies within central hilly region. Materials and Methods: This is a community based cross-sectional survey research conducted in rural area of Kathmandu valley. Two hundred and forty currently married women with at least one child of any age were interviewed using a structured pre-tested questionnaire. Results: More than four-fifth of the respondents intended to undergo sterilization. Almost two-third of them wanted to limit their family size by taking this option. More than one-third of women not-intending to undergo sterilization feared weakness after sterilization. Age of the respondents, duration of marriage, and number of living children were significantly associated with intention to undergo sterilization. 15-24 years age group were six times more likely to have the intention for sterilization (OR 6.79, CI 2.28-20.19) compared to age 35 years and above group. Mothers with less than 3 living children are about three times more likely to have the intention to undergo sterilization (OR 2.87, CI 1.3-6.33) compared to women with more than 2 living children. Women married for 6 to 10 years were three times more likely to have the intention (OR 3.0, CI 1.09-8.27). However, gender of the living children was not associated with intention to undergo sterilization. Conclusion: There were significant numbers of women intending to undergo sterilization. Age of the mother, number of living children and the duration of marriage were found to be significantly influencing the intention to undergo sterilization. However, as intention refers to future plan, the respondents’ intention may change over time. The national family planning program also needs to identify the key factors in accepting the sterilization and target these women to increase utilization. PMID:27152235

  10. Radiation-treated ready-to-eat (RTE) chicken breast Adobo for immuno-compromised patients.

    PubMed

    Feliciano, Chitho P; De Guzman, Zenaida M; Tolentino, Levelyn Mitos M; Cobar, Maria Lucia C; Abrera, Gina B

    2014-11-15

    Usually in hospitals low-bacterial diets are served to immuno-compromised patients (ICPs). However, low-bacterial diets still pose a high risk of microbial infections and limit the food selection of the patients. Thus, pathogen-free dishes must be made available. This study presents the development of pathogen-free ready-to-eat (RTE) Filipino ethnic food chicken breast Adobo, sterilized by exposure to high-dose gamma rays (25 kGy) in combination with conventional treatments. Frozen vacuum-packed samples artificially inoculated with Escherichia coli, Listeria monocytogenes, Bacillus cereus, Staphylococcus aureus and Salmonella enterica subsp. enterica serovar Typhimurium, were exposed to 25 kGy gamma radiation for complete sterilization. Microbial quality and sterility of the samples were analysed following 15, 30, and 60 days of storage at -4°C. The effects of high-dose gamma irradiation on the nutritional quality and sensory characteristics of RTE chicken breast Adobo were also evaluated. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Implications of Higgs’ universality for physics beyond the Standard Model

    NASA Astrophysics Data System (ADS)

    Goldman, T.; Stephenson, G. J.

    2017-06-01

    We emulate Cabibbo by assuming a kind of universality for fermion mass terms in the Standard Model. We show that this is consistent with all current data and with the concept that deviations from what we term Higgs’ universality are due to corrections from currently unknown physics of nonetheless conventional form. The application to quarks is straightforward, while the application to leptons makes use of the recognition that Dark Matter can provide the “sterile” neutrinos needed for the seesaw mechanism. Requiring agreement with neutrino oscillation results leads to the prediction that the mass eigenstates of the sterile neutrinos are separated by quadratically larger ratios than for the charged fermions. Using consistency with the global fit to LSND-like, short-baseline oscillations to determine the scale of the lowest mass sterile neutrino strongly suggests that the recently observed astrophysical 3.55 keV γ-ray line is also consistent with the mass expected for the second most massive sterile neutrino in our analysis.

  12. [Biocompatibility of peritoneal dialysis fluids].

    PubMed

    Boulanger, Eric; Moranne, Olivier; Wautier, Marie-Paule; Rougier, Jean-Phillipe; Ronco, Pierre; Pagniez, Dominique; Wautier, Jean-Luc

    2005-03-01

    Repeated and long-term exposure to conventional glucose-based peritoneal dialysis fluids (PDFs) with poor biocompatibility plays a central role in the pathogenesis of the functional and structural changes of the peritoneal membrane. We have used immortalized human peritoneal mesothelial cells in culture to assess in vitro the biocompatibility of PDFs. Low pH, high glucose concentration and heat sterilization represent major factors of low biocompatibility. Two recent groups of glucose derivatives have been described. Glucose degradation products (GDPs) are formed during heat sterilization (glycoxidation) and storage. GDPs can bind protein and form AGEs (Advanced Glycation End-products), which can also result from the binding of glucose to free NH2 residues of proteins (glycation). The physiological pH, and the separation of glucose during heat sterilization (low GDP content) in the most recent PDFs dramatically increase the biocompatibility. The choice of PD programs with high biocompatibility PDFs allows preserving the function of the peritoneal membrane. Improvement of PDF biocompatibility may limit the occurrence of chronic chemical peritonitis and may allow long-term PD treatment.

  13. Female sterilization: update on clinical efficacy, side effects and contraindications.

    PubMed

    Gizzo, Salvatore; Bertocco, Anna; Saccardi, Carlo; Di Gangi, Stefania; Litta, Pietro Salvatore; D'antona, Donato; Nardelli, Giovanni Battista

    2014-10-01

    The aim of this review is to compare studies concerning female sterilization in order to define the most suitable approach and device for each patient considering timing, safety, cost-effectiveness, failure rate, complication rate and patient satisfaction. A systematic literature search was conducted in electronic databases MEDLINE-EMBASE-Sciencedirect and Cochrane Library between 2000 and 2012. All original descriptions, case reports, retrospective and review articles on tubal sterilization methods have been considered. Outcome measures were effectiveness, tolerability, procedure complications and female satisfaction. The ideal female sterilization system should be a simple, safe, highly efficient, easily learned, inexpensive, one-time procedure without negative side-effects. Nowadays, the trans-cervical approach is associated with minimal postoperative pain, allowing short hospitalization and fast resumption of daily activities. Laparoscopic and laparotomic approaches are considered second choices, since, particularly in developing countries, the transcervical hysteroscopic methods will increasingly spread within gynaecological clinical practice. Safety issues, hospital stay, costs and surgeons' experience are important factors in decision-making of the method for female sterilization. Hysteroscopic devices should be preferred when possible. The counselling time remains a fundamental step in choice. The decision concerning method depends on the setting, the surgeon's experience, the country's economical development and the woman's preference.

  14. Contraception Update: Sterilization.

    PubMed

    Antell, Karen; Deshmukh, Prium; Brown, Elizabeth J

    2017-11-01

    Female sterilization procedures include postpartum partial salpingectomy via cesarean or minilaparotomy incision, interval laparoscopic procedures, or hysteroscopic placement of microinserts. Rates of failure and serious complications are low and comparable among the various methods. A hysteroscopic procedure requires a 3-month confirmatory hysterosalpingogram before it is considered effective for contraception. Hysteroscopic sterilization has been shown to be associated with a higher reoperation rate than laparoscopic procedures. For male sterilization, vasectomy is a noninvasive and highly effective method. Vasectomy is an outpatient procedure performed under local anesthesia. The procedure requires confirmation of azoospermia with a semen analysis 8 to 16 weeks after the procedure. Patients who are considering sterilization should be counseled about all the available options and the permanent nature of such procedures. Written permission from the American Academy of Family Physicians is required for reproduction of this material in whole or in part in any form or medium.

  15. Spray method for recovery of heat-injured Salmonella Typhimurium and Listeria monocytogenes.

    PubMed

    Back, Kyeong-Hwan; Kim, Sang-Oh; Park, Ki-Hwan; Chung, Myung-Sub; Kang, Dong-Hyun

    2012-10-01

    Selective agar is inadequate for supporting recovery of injured cells. During risk assessment of certain foods, both injured and noninjured cells must be enumerated. In this study, a new method (agar spray method) for recovering sublethally heat-injured microorganisms was developed and used for recovery of heat-injured Salmonella Typhimurium and Listeria monocytogenes. Molten selective agar was applied as an overlay to presolidified nonselective tryptic soy agar (TSA) by spray application. Heat-injured cells (55°C for 10 min in 0.1% peptone water or 55°C for 15 min in sterilized skim milk) were inoculated directly onto solidified TSA. After a 2-h incubation period for cell repair, selective agar was applied to the TSA surface with a sprayer, and the plates were incubated. The recovery rate for heat-injured Salmonella Typhimurium and L. monocytogenes with the spray method was compared with the corresponding rates associated with TSA alone, selective media alone, and the conventional overlay method (selective agar poured on top of resuscitated cells grown on TSA and incubated for 2 h). No significant differences (P > 0.05) were found in pathogen recovery obtained with TSA, the overlay method, and the spray method. However, a lower recovery rate (P < 0.05) was obtained for isolation of injured cells on selective media. Overall, these results indicate that the agar spray method is an acceptable alternative to the conventional overlay method and is a simpler and more convenient approach to recovery and detection of injured cells.

  16. Hysteroscopic Sterilization: History and Current Methods

    PubMed Central

    Greenberg, James A

    2008-01-01

    For many practicing obstetrician-gynecologists, tubal ligation was the gold standard by which female sterilization techniques were measured. Yet gynecologic surgeons have simultaneously sought to occlude the fallopian tubes transcervically to avoid discomfort and complications associated with transabdominal approaches. In this review, the history of transcervical sterilization is discussed. Past, current, and upcoming techniques are reviewed. This article focuses on interval sterilization techniques, thus removing post-vaginal and post-cesarean delivery tubal ligations from the discussion. PMID:19015762

  17. Physician opinions regarding elective bilateral salpingectomy with hysterectomy and for sterilization.

    PubMed

    Gill, Sarah E; Mills, Benjie B

    2013-01-01

    To gather opinions about the benefits and concerns of performing bilateral salpingectomy without oophorectomy during hysterectomy for benign indications and as a sterilization procedure. Survey study (Canadian Task Force classification III). Practicing physicians in US institutions that have obstetrics and gynecology residency programs listed on the FREIDA website were surveyed electronically. A validated, standardized questionnaire designed to gather opinions about bilateral salpingectomy performed during hysterectomy or for sterilization was administered via SurveyMonkey to practitioners of obstetrics and gynecology. Results were compiled and presented as percentages of total responders. A total of 234 surveys were returned. Fifty-four percent of physicians perform bilateral salpingectomy during hysterectomy, most commonly to reduce the risks of cancer (75%) and repeat operation (49.1%). Of the 45.5% of physicians who do not perform bilateral salpingectomy during hysterectomy, most (69.4%) believe there is no benefit. Fifty-eight percent of practitioners believe that bilateral salpingectomy is the most effective method of sterilization after age 35 years but choose this method only in patients in whom one sterilization procedure has failed or because of tubal disease. Only 7.2% of surgeons prefer it as an interval sterilization procedure. Most practitioners believe that bilateral salpingectomy is beneficial. Most also believe that bilateral salpingectomy is the most effective sterilization procedure; however, only 7.2% use this method as an interval procedure. More data are needed to evaluate the prophylactic effect of bilateral salpingectomy against postoperative sequelae. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.

  18. Managing feral cats on a university's campuses: how many are there and is sterilization having an effect?

    PubMed

    Jones, Amanda L; Downs, Colleen T

    2011-01-01

    Worldwide domestic and feral cat (Felis catus) numbers have increased. Concerns regarding high populations of feral cats in urban areas include wildlife predation, public nuisance, and disease. This study aimed to estimate the size of the feral cat population on 5 campuses of the University of KwaZulu-Natal, South Africa, to determine whether sterilization has an effect and to make management recommendations. The study used both the total count and mark-recapture methods to estimate the feral cat population on each campus. The study chose a noninvasive method of taking photographs to "mark" individuals and record those who were sterilized. The study estimated a total of 186 cats on all campuses and density at 161 cats km(-2). There was a negative relationship between sterilization and numbers. Sites with higher sterilization showed a lower proportion of younger cats. At the average sterilization of 55%, the population, according to predictions, would remain stable at fecundity, survival, and immigration rates reported by cat caretakers. However, caretakers underestimated cat abundance by 7 ± 37 SD%. Caretakers' feral cat sterilization and feeding programs appear to provide a service to the university community. Key management recommendations were to increase sterilization to 90% to reduce the population over the long term and to raise funds to support the costs incurred by voluntary cat caretakers.

  19. Does a History of Unintended Pregnancy Lessen the Likelihood of Desire for Sterilization Reversal?

    PubMed Central

    Grady, Cynthia D.; Schwarz, Eleanor Bimla; Emeremni, Chetachi A.; Yabes, Jonathan; Akers, Aletha; Zite, Nikki

    2013-01-01

    Abstract Background Unintended pregnancy has been significantly associated with subsequent female sterilization. Whether women who are sterilized after experiencing an unintended pregnancy are less likely to express desire for sterilization reversal is unknown. Methods This study used national, cross-sectional data collected by the 2006–2010 National Survey of Family Growth. The study sample included women ages 15–44 who were surgically sterile from a tubal sterilization at the time of interview. Multivariable logistic regression was used to examine the relationship between a history of unintended pregnancy and desire for sterilization reversal while controlling for potential confounders. Results In this nationally representative sample of 1,418 women who were sterile from a tubal sterilization, 78% had a history of at least one unintended pregnancy and 28% expressed a desire to have their sterilization reversed. In unadjusted analysis, having a prior unintended pregnancy was associated with higher odds of expressing desire for sterilization reversal (odds ratio [OR]: 1.80; 95% confidence interval [CI]: 1.15–2.79). In adjusted analysis controlling for sociodemographic factors, unintended pregnancy was no longer significantly associated with desire for reversal (OR: 1.46; 95% CI: 0.91–2.34). Conclusion Among women who had undergone tubal sterilization, a prior history of unintended pregnancy did not decrease desire for sterilization reversal. PMID:23621776

  20. Effectiveness of Rack Sanitation Procedures for Elimination of Bacteria from Automatic Watering Manifolds.

    PubMed

    Costello, Terry; Watkins, Linda; Straign, Mike; Bean, William; Toth, Linda; Rehg, Jerold

    1998-03-01

    An important responsibility of animal care programs is to protect research animals from exposure to potentially pathogenic microorganisms. To validate the need for steam sterilization of rodent automatic watering racks, we evaluate the post-sanitation microbial contamination of experimentally inoculated racks and of racks that had been used to house conventional mice. We tested three sanitation protocols: rack-washer sanitation without manifold flush, sanitation that included manifold flush, and sanitation that included manifold flush followed by autoclaving. Rack sanitation, with or without manifold flush, did not reliably eliminate microbial flora from the lixits or manifold drainage water. A total of 43% of all non-autoclaved racks were positive for bacterial contamination after sanitation, and racks that had been used for conventional animal housing were more frequently positive than were experimentally inoculated racks (79% vs 18%). These data indicate that steam sterilization is necessary for eliminating bacteria from automatic watering systems. These observations are particularly important in light of increasing numbers of immune-impaired rodents that may be inadvertently and unnecessarily exposed to microbial pathogens via the automatic watering system.

  1. Proposal for a new categorization of aseptic processing facilities based on risk assessment scores.

    PubMed

    Katayama, Hirohito; Toda, Atsushi; Tokunaga, Yuji; Katoh, Shigeo

    2008-01-01

    Risk assessment of aseptic processing facilities was performed using two published risk assessment tools. Calculated risk scores were compared with experimental test results, including environmental monitoring and media fill run results, in three different types of facilities. The two risk assessment tools used gave a generally similar outcome. However, depending on the tool used, variations were observed in the relative scores between the facilities. For the facility yielding the lowest risk scores, the corresponding experimental test results showed no contamination, indicating that these ordinal testing methods are insufficient to evaluate this kind of facility. A conventional facility having acceptable aseptic processing lines gave relatively high risk scores. The facility showing a rather high risk score demonstrated the usefulness of conventional microbiological test methods. Considering the significant gaps observed in calculated risk scores and in the ordinal microbiological test results between advanced and conventional facilities, we propose a facility categorization based on risk assessment. The most important risk factor in aseptic processing is human intervention. When human intervention is eliminated from the process by advanced hardware design, the aseptic processing facility can be classified into a new risk category that is better suited for assuring sterility based on a new set of criteria rather than on currently used microbiological analysis. To fully benefit from advanced technologies, we propose three risk categories for these aseptic facilities.

  2. A review of sterilization, packaging and storage considerations for orthodontic pliers.

    PubMed

    Papaioannou, Angeliki

    2013-01-01

    Wrapping dental instruments along with a chemical indicator is considered an essential step of a reliable infection control protocol. Hinged instruments, such as orthodontic pliers, are particular because they must be sterilized in an open position. Different methods to sterilize, package and store orthodontic pliers are reviewed and discussed.

  3. Sterilization of fermentation vessels by ethanol/water mixtures

    DOEpatents

    Wyman, Charles E.

    1999-02-09

    A method for sterilizing process fermentation vessels with a concentrated alcohol and water mixture integrated in a fuel alcohol or other alcohol production facility. Hot, concentrated alcohol is drawn from a distillation or other purification stage and sprayed into the empty fermentation vessels. This sterilizing alcohol/water mixture should be of a sufficient concentration, preferably higher than 12% alcohol by volume, to be toxic to undesirable microorganisms. Following sterilization, this sterilizing alcohol/water mixture can be recovered back into the same distillation or other purification stage from which it was withdrawn. The process of this invention has its best application in, but is not limited to, batch fermentation processes, wherein the fermentation vessels must be emptied, cleaned, and sterilized following completion of each batch fermentation process.

  4. Geographic variation in characteristics of postpartum women using female sterilization

    PubMed Central

    White, Kari; Potter, Joseph E.; Zite, Nikki

    2015-01-01

    Background Southern states have higher rates of female sterilization compared to other areas of the United States, and the reasons for this are not well understood. We examined whether low-income and racial/ethnic minority women, who were previous targets of coercive practices, disproportionately report using sterilization in the South. Methods We used data from 12 states participating in the Pregnancy Risk Assessment Monitoring System that collected information on women’s contraceptive method use between 2006–2009. We categorized states according to geographic region: South, Midwest/West and Northeast. Within each region, we computed the percentage of women using sterilization according to their demographic and obstetric characteristics and estimated multivariable-adjusted prevalence ratios to evaluate whether the same characteristics were associated with sterilization use. Findings The percentage of postpartum women using sterilization ranged from 5.0–9.9% in the Northeast, 8.9–10.6% in the Midwest/West and 11.6–22.4% in the South. Women in nearly all sub-groups in Southern states were more likely to use sterilization than women in the Northeast. After multivariable adjustment, there were no significant differences in the prevalence of sterilization for Blacks compared to Whites in the Northeast (0.76 [95% CI: 0.55–1.06]), Midwest/West (0.91 [95%CI: 0.80–1.04]) and South (0.96 [95%CI: 0.85–1.07]). Women with Medicaid-paid deliveries (versus private insurance) had a higher prevalence of sterilization in all regions (p<0.05). Conclusions These findings do not indicate that low-income and racial/ethnic minority women in the South use sterilization at disproportionately higher rates compared to other regions, and suggest that other differences, such as social norms and family planning policies, may contribute to this geographic variation. PMID:26232310

  5. Effects of gamma irradiation dose-rate on sterile male Aedesaegypti

    NASA Astrophysics Data System (ADS)

    Ernawan, Beni; Tambunan, Usman Sumo Friend; Sugoro, Irawan; Sasmita, Hadian Iman

    2017-06-01

    Aedesaegypti is the most important vector for dengue, yellow fever and Zika viruses. Considering its medical importance, vector population control program utilizing radiation-based sterile insect technique (SIT) is one of the potential methods for preventing and limiting the dispersal of these viruses. The present study was undertaken to evaluate the dose-rates effects of γ-sterilization on quality parameters of sterile males. Males Ae.aegypti at the pupal stage were sterilized by applying 70 Gyγ-rays in varies dose-rates, i.e. 0 (control), 300, 600, 900, 1200 and 1500Gy/h utilizing panoramic irradiator. Adult males that emerged from the pupal stage were assessed for their quality parameters, which are the percentage of emergence, longevity, sterility and mating competitiveness. The results herein indicate that there was no major effect of dose-rate on the percentage of emergence, the data showedthat there were no differences between irradiated males compared with control. Generally, the longevity of irradiated males was lower compared to control. The data also demonstrated that longevity was significantly increased at the dose-rate from 300 to 900Gy/h, then decreased at the dose-rate 900 to 1500 Gy/h. Sterility of irradiated maleswas significantly different compared to control, while there was no significantly different at dose rate 300 to 1500 Gy/h. Mating competitiveness of irradiated males was increased at the dose rate from 300 to 1200 Gy/h, then the value was decreased significantly at the dose rate 1500 Gy/h. The dose-rate effects of γ-sterilization were discussed in the context genetic vector control, in particular, the SIT. The results give information and contribute to better understanding towards γ-sterilization optimization and quality parameters of sterile male Ae. aegypti on SIT methods.

  6. Supercritical CO2 assisted process for the production of high-purity and sterile nano-hydroxyapatite/chitosan hybrid scaffolds.

    PubMed

    Ruphuy, G; Souto-Lopes, M; Paiva, D; Costa, P; Rodrigues, A E; Monteiro, F J; Salgado, C L; Fernandes, M H; Lopes, J C; Dias, M M; Barreiro, M F

    2018-04-01

    Hybrid scaffolds composed of hydroxyapatite (HAp), in particular in its nanometric form (n-HAp), and chitosan (CS) are promising materials for non-load-bearing bone graft applications. The main constraints of their production concern the successful implementation of the final purification/neutralization and sterilization steps. Often, the used purification strategies can compromise scaffold structural features, and conventional sterilization techniques can result in material's thermal degradation and/or contamination with toxic residues. In this context, this work presents a process to produce n-HAp/CS scaffolds mimicking bone composition and structure, where an innovative single step based on supercritical CO 2 extraction was used for both purification and sterilization. A removal of 80% of the residual acetic acid was obtained (T = 75°C, p = 8.0 MPa, 2 extraction cycles of 2 h) giving rise to scaffolds exhibiting adequate interconnected porous structure, fast swelling and storage modulus compatible with non-load-bearing applications. Moreover, the obtained scaffolds showed cytocompatibility and osteoconductivity without further need of disinfection/sterilization procedures. Among the main advantages, the proposed process comprises only three steps (n-HAp/CS dispersion preparation; freeze-drying; and supercritical CO 2 extraction), and the supercritical CO 2 extraction show clear advantages over currently used procedures based on neutralization steps. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 965-975, 2018. © 2017 Wiley Periodicals, Inc.

  7. Tubal anastomosis after previous sterilization: a systematic review.

    PubMed

    van Seeters, Jacoba A H; Chua, Su Jen; Mol, Ben W J; Koks, Carolien A M

    2017-05-01

    Female sterilization is one of the most common contraceptive methods. A small number of women, however, opt for reversal of sterilization procedures after they experience regret. Procedures can be performed by laparotomy or laparoscopy, with or without robotic assistance. Another commonly utilized alternative is IVF. The choice between surgery and IVF is often influenced by reimbursement politics for that particular geographic location. We evaluated the fertility outcomes of different surgical methods available for the reversal of female sterilization, compared these to IVF and assessed the prognostic factors for success. Two search strategies were employed. Firstly, we searched for randomized and non-randomized clinical studies presenting fertility outcomes of sterilization reversal up to July 2016. Data on the following outcomes were collected: pregnancy rate, ectopic pregnancy rate, cost of the procedure and operative time. Eligible study designs included prospective or retrospective studies, randomized controlled trials, cohort studies, case-control studies and case series. No age restriction was applied. Exclusion criteria were patients suffering from tubal infertility from any other reason (e.g. infection, endometriosis and adhesions from previous surgery) and studies including <10 participants. The following factors likely to influence the success of sterilization reversal procedures were then evaluated: female age, BMI and duration and method of sterilization. Secondly, we searched for randomized and non-randomized clinical studies that compared reversal of sterilization to IVF and evaluated them for pregnancy outcomes and cost effectiveness. We included 37 studies that investigated a total of 10 689 women. No randomized controlled trials were found. Most studies were retrospective cohort studies of a moderate quality. The pooled pregnancy rate after sterilization reversal was 42-69%, with heterogeneity seen from the different methods utilized. The reported ectopic pregnancy rate was 4-8%. The only prognostic factor affecting the chance of conception was female age. The surgical approach (i.e. laparotomy [microscopic], laparoscopy or robotic) had no impact on the outcome, with the exception of the macroscopic laparotomic technique, which had inferior results and is not currently utilized. For older women, IVF could be a more cost-effective alternative for the reversal of sterilization. However, direct comparative data are lacking and a cut-off age cannot be stated. In sterilized women who suffer regret, surgical tubal re-anastomosis is an effective treatment, especially in younger women. However, there is a need for randomized controlled trials comparing the success rates and costs of surgical reversal with IVF. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  8. High Temperature Induced Glume Closure Resulted in Lower Fertility in Hybrid Rice Seed Production.

    PubMed

    Yan, Haoliang; Zhang, Binglin; Zhang, Yunbo; Chen, Xinlan; Xiong, Hui; Matsui, Tsutomu; Tian, Xiaohai

    2016-01-01

    Predicted climate changes, in particular, the increased dimension and frequency of heat waves, are expected to affect crop growth in the future seriously. Hybrid rice relies on seed production from male sterile and restorer lines. Experiments were conducted over two consecutive years to compare the high temperature tolerance of parents of different hybrid rice combinations, in terms of fertility rate, flowering pattern, pollination and physiological parameters of the lodicule. Three male sterile lines and a broad compatibility restorer line (as pollen donor and conventional variety as well) were grown to heading stage and then treated with average daily temperatures of 26°C (range 23-30°C), 28°C (25-32°C), and 30°C (26-34°C), respectively, continued for 5-7 days each in a natural light phytotron which simulated the local typical high temperature weather in the field. The results indicated that male sterile lines were more sensitive to high temperature than the restorer line for fertility rate, and the sensitivity varied between varieties. The fertility rate of the restorer line was maintained at about 90% under the high temperature treatments, while it decreased in the male sterile lines by 23.3 and 48.1% at 28 and 30°C, respectively. The fertility rate of the most sensitive line declined by 70%, and the tolerant line declined by 34% at 30°C. Glume closure in the male sterile lines was a major reason for the reduced fertility rate under high temperature, which is closely correlated with carbohydrates content and the vascular bundle pattern in the lodicule. The present study identified a useful trait to select male sterile lines with high temperature tolerance for seed production.

  9. Analysis of severely fractured glenoid components: clinical consequences of biomechanics, design, and materials selection on implant performance.

    PubMed

    Ansari, Farzana; Lee, Taylor; Malito, Louis; Martin, Audrey; Gunther, Stephen B; Harmsen, Samuel; Norris, Tom R; Ries, Mike; Van Citters, Douglas; Pruitt, Lisa

    2016-07-01

    The longevity of total shoulder replacement is primarily limited by the performance of the ultrahigh-molecular-weight polyethylene (UHMWPE) glenoid component in vivo. Variations in glenoid design (conformity, thickness), biomechanics (joint kinematics), and UHMWPE material selection (sterilization, cross-linking) distinguish total shoulder replacements from hip and knee arthroplasty devices. These variables can lead to severe mechanical failures, including gross fracture. Sixteen retrieved glenoids with severe fracture were analyzed. The explant cohort included 3 material groups (gamma-sterilized Hylamer; gamma-sterilized UHMWPE; and gas plasma-sterilized, remelted, highly cross-linked UHMWPE [HXL]) and a range of conformities (0- to 10-mm radial mismatch). Analysis included fractography (optical and scanning electron microscopy) and Fourier transform infrared spectroscopy for oxidative analysis. Fracture primarily occurred along the exterior rim for all 16 explants. Fourier transform infrared analysis and fractography revealed significant oxidative embrittlement for all gamma-sterilized glenoids. Fatigue striations and internal flaws were evident on the fracture surface of the HXL glenoid, with little oxidation detected. Fracture initiated at the external rim of all devices. Elevated oxidation levels and visible material distortion for representative gamma-sterilized conventional and Hylamer devices suggest oxidative embrittlement as a driving force for crack inception and subsequent fracture. Brittle fracture of theHXL glenoid resulted from a combination of elevated contact stress due to a nonconforming surface, an internal flaw, and reduced resistance to fatigue crack growth. This demonstrates that glenoid fracture associated with oxidation has not been eliminated with the advent of modern materials (HXL) in the shoulder domain. Basic Science Study; Implant Retrieval Study. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  10. Effects of sterilization methods on key properties of specialty optical fibers used in medical devices

    NASA Astrophysics Data System (ADS)

    Stolov, Andrei A.; Slyman, Brian E.; Burgess, David T.; Hokansson, Adam S.; Li, Jie; Allen, R. Steve

    2013-03-01

    Optical fibers with different types of polymer coatings were exposed to three sterilization conditions: multiple autoclaving, treatment with ethylene oxide and treatment with gamma rays. Effects of different sterilization techniques on key optical and mechanical properties of the fibers are reported. The primary attention is given to behavior of the coatings in harsh sterilization environments. The following four coating/buffer types were investigated: (i) dual acrylate, (ii) polyimide, (iii) silicone/PEEK and (iv) fluoroacrylate hard cladding/ETFE.

  11. Evaluation of sterilization of dental handpieces by heating in synthetic compressor lubricant.

    PubMed

    Silverstone, S E; Hill, D E

    1999-01-01

    The Centers for Disease Control and Prevention and the American Dental Association guidelines recommend sterilization of dental handpieces after each use. Steam autoclaving is the most commonly used sterilization method. However, pressurized steam causes corrosion and partial combustion of the handpiece lubricant, leaving a sticky carbon residue on the turbine which must then be replaced after several usages. Replacement of autoclave-damaged dental handpieces represents a major expense for dentists that may be avoided through the use of less destructive sterilization techniques.

  12. Radiation sterilization of tissue allografts: A review.

    PubMed

    Singh, Rita; Singh, Durgeshwer; Singh, Antaryami

    2016-04-28

    Tissue substitutes are required in a number of clinical conditions for treatment of injured and diseased tissues. Tissues like bone, skin, amniotic membrane and soft tissues obtained from human donor can be used for repair or reconstruction of the injured part of the body. Allograft tissues from human donor provide an excellent alternative to autografts. However, major concern with the use of allografts is the risk of infectious disease transmission. Therefore, tissue allografts should be sterilized to make them safe for clinical use. Gamma radiation has several advantages and is the most suitable method for sterilization of biological tissues. This review summarizes the use of gamma irradiation technology as an effective method for sterilization of biological tissues and ensuring safety of tissue allografts.

  13. Radiation sterilization of tissue allografts: A review

    PubMed Central

    Singh, Rita; Singh, Durgeshwer; Singh, Antaryami

    2016-01-01

    Tissue substitutes are required in a number of clinical conditions for treatment of injured and diseased tissues. Tissues like bone, skin, amniotic membrane and soft tissues obtained from human donor can be used for repair or reconstruction of the injured part of the body. Allograft tissues from human donor provide an excellent alternative to autografts. However, major concern with the use of allografts is the risk of infectious disease transmission. Therefore, tissue allografts should be sterilized to make them safe for clinical use. Gamma radiation has several advantages and is the most suitable method for sterilization of biological tissues. This review summarizes the use of gamma irradiation technology as an effective method for sterilization of biological tissues and ensuring safety of tissue allografts. PMID:27158422

  14. Manipulation of the microbiota of mass-reared Mediterranean fruit flies Ceratitis capitata (Diptera: Tephritidae) improves sterile male sexual performance.

    PubMed

    Ben Ami, Eyal; Yuval, Boaz; Jurkevitch, Edouard

    2010-01-01

    The sterile insect technique (SIT) is a method of biological control whereby millions of factory reared sterile male insects are released into the field. This technique is commonly used to combat the Mediterranean fruit fly (Ceratitis capitata, Diptera: Tephritidae). Sterile medfly males are less competent in attracting and mating with wild females, a property commonly linked to the irradiation process responsible for the sterilization. As bacteria are important partners in the fly's life cycle, we used molecular analytical methods to study the community structure of the gut microbiota in irradiated male medflies. We find that the sterilizing irradiation procedure affects the gut bacterial community structure of the Mediterranean fruit fly. Although the Enterobacteriaceae family remains the dominant bacterial group present in the gut, the levels of Klebsiella species decreases significantly in the days after sterilization. In addition, we detected substantial differences in some bacterial species between the mass rearing strain Vienna 8 and the wild strain. Most notable among these are the increased levels of the potentially pathogenic species Pseudomonas in the industrial strain. Testing the hypothesis that regenerating the original microbiota community could result in enhanced competitiveness of the sterile flies, we found that the addition of the bacterial species Klebsiella oxytoca to the postirradiation diet enables colonization of these bacteria in the gut while resulting in decreased levels of the Pseudomonas sp. Feeding on diets containing bacteria significantly improved sterile male performance in copulatory tests. Further studies will determine the feasibility of bacterial amelioration in SIT operations.

  15. Public Law 100-461, Foreign Operations, Export Financing and Related Programs Appropriations Act, 1989, 1 October 1988.

    PubMed

    1988-01-01

    This Act does the following among other things: 1) prohibits using funds appropriated under the Act to lobby for abortion and 2) prohibits making development assistance funds available 1) to pay for abortions as a method of family planning (FP) or to motivate or coerce any person to perform abortions; 2) to pay for involuntary sterilization as a method of FP or to coerce or provide any financial incentive to any person to undergo sterilization; 3) to pay for biomedical research that relates to the methods of, or performance of, abortions or involuntary sterilization as a means of FP; or 4) to any country or organization if the use of such funds by such country or organization would violate any of the abortion or involuntary sterilization provisions. It also reaffirms the commitment of the US Congress to population, development assistance, and the need for informed voluntary FP. full text

  16. Multilevel Perspectives on Female Sterilization in Low-Income Communities in Mumbai, India.

    PubMed

    Brault, Marie A; Schensul, Stephen L; Singh, Rajendra; Verma, Ravi K; Jadhav, Kalpita

    2016-09-01

    Surgical sterilization is the primary method of contraception among low-income women in India. This article, using qualitative analysis of key informant, in-depth interviews, and quantitative analyses, examines the antecedents, process, and outcomes of sterilization for women in a low-income area in Mumbai, India. Family planning policies, socioeconomic factors, and gender roles constrain women's reproductive choices. Procedures for sterilization rarely follow protocol, particularly during pre-procedure counseling and consent. Women who choose sterilization often marry early, begin conceiving soon after marriage, and reach or exceed ideal family size early due to problems in accessing reversible contraceptives. Despite these constraints, this study indicates that from the perspective of women, the decision to undergo sterilization is empowering, as they have fulfilled their reproductive duties and can effectively exercise control over their fertility and sexuality. This empowerment results in little post-sterilization regret, improved emotional health, and improved sexual relationships following sterilization. © The Author(s) 2015.

  17. System for creating on site, remote from a sterile environment, parenteral solutions

    NASA Technical Reports Server (NTRS)

    Finley, Mike (Inventor); Scharf, Mike (Inventor); Packard, Jeff (Inventor); Kipp, Jim (Inventor); Dudar, Tom (Inventor); Owens, Jim (Inventor); Bindokas, Al (Inventor)

    1996-01-01

    The present invention provides a system and method for creating on site, remote from a sterile environment, parenteral solutions in large volume parenteral containers for intravenous administration to a patient. In an embodiment, this system comprises an empty large volume container including at least one port for accessing an interior of the container. The port includes a sterilizing filter for sterilizing a fluid fed through the port into the container. A second container is provided including a solute and having means for coupling the second container to the large volume container and thereby providing fluid communication therebetween allowing the solute to be received within the interior of the container. A sterile water source is also provided including means for placing the sterile water source in fluid communication with the port and allowing water to flow from the sterile water source into the interior of the container. This allows the solute, and sterile water that has been fed through the filter, to create a parenteral solution in the large volume parenteral container.

  18. The development of new radiation protocols for insect sterilization using long wavelength x-rays

    NASA Astrophysics Data System (ADS)

    Urquidi, Jacob; Brar, Ramaninder K.; Rodriguez, Stacy; Hansen, Immo

    2015-07-01

    Control of insect species for the protection of crops, livestock, and prevention of disease such as dengue fever and malaria is a high priority in today's global economy. Traditional methods such as pesticides have fallen out of favor because its effects are indiscriminate as well as adverse and unpredictable impacts on the environment. Modern novel techniques such as genetic modification have had trouble gaining traction due to ethics concerns and the potential for unforeseen side effects. One approach that has gained traction and has proven its efficacy is the use of ionizing radiation to affect sterility in insect species in order to scale back their population. Known as Sterile Insect Technique (SIT), it has proven very effective in eradicating certain dipteran insect populations. However, when standard sterilization methods developed for dipertans are applied to mosquito populations significant complications arise, such as an inability to compete with non-irradiated males and high mortality rates. We have investigated the effect of treatment with x-rays of different wavelengths on x-ray sterilized mosquito males. Our results have demonstrated that longer wavelength x-rays have a significant effect on the outcome of the sterile males' longevity as well as an increase on the efficacy of sterilization while employing a substantially lower dose.

  19. The development of new radiation protocols for insect sterilization using long wavelength x-rays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Urquidi, Jacob, E-mail: jurquidi@nmsu.edu; Brar, Ramaninder K.; Rodriguez, Stacy

    Control of insect species for the protection of crops, livestock, and prevention of disease such as dengue fever and malaria is a high priority in today’s global economy. Traditional methods such as pesticides have fallen out of favor because its effects are indiscriminate as well as adverse and unpredictable impacts on the environment. Modern novel techniques such as genetic modification have had trouble gaining traction due to ethics concerns and the potential for unforeseen side effects. One approach that has gained traction and has proven its efficacy is the use of ionizing radiation to affect sterility in insect species inmore » order to scale back their population. Known as Sterile Insect Technique (SIT), it has proven very effective in eradicating certain dipteran insect populations. However, when standard sterilization methods developed for dipertans are applied to mosquito populations significant complications arise, such as an inability to compete with non-irradiated males and high mortality rates. We have investigated the effect of treatment with x-rays of different wavelengths on x-ray sterilized mosquito males. Our results have demonstrated that longer wavelength x-rays have a significant effect on the outcome of the sterile males’ longevity as well as an increase on the efficacy of sterilization while employing a substantially lower dose.« less

  20. Gamma sterilization of pharmaceuticals--a review of the irradiation of excipients, active pharmaceutical ingredients, and final drug product formulations.

    PubMed

    Hasanain, Fatima; Guenther, Katharina; Mullett, Wayne M; Craven, Emily

    2014-01-01

    Sterilization by gamma irradiation has shown a strong applicability for a wide range of pharmaceutical products. Due to the requirement for terminal sterilization where possible in the pharmaceutical industry, gamma sterilization has proven itself to be an effective method as indicated by its acceptance in the European Pharmacopeia and the United States Pharmacopeia ( ). Some of the advantages of gamma over competitive procedures include high penetration power, isothermal character (small temperature rise), and no residues. It also provides a better assurance of product sterility than aseptic processing, as well as lower validation demands. Gamma irradiation is capable of killing microorganisms by breaking their chemical bonds, producing free radicals that attack the nucleic acid of the microorganism. Sterility by gamma irradiation is achieved mainly by the alteration of nucleic acid and preventing the cellular division. This review focuses on the extensive application of gamma sterilization to a wide range of pharmaceutical components including active pharmaceutical ingredients, excipients, final drug products, and combination drug-medical devices. A summary of the published literature for each class of pharmaceutical compound or product is presented. The irradiation conditions and various quality control characterization methodologies that were used to determine final product quality are included, in addition to a summary of the investigational outcomes. Based on this extensive literature review and in combination with regulatory guidelines and other published best practices, a decision tree for implementation of gamma irradiation for pharmaceutical products is established. This flow chart further facilitates the implementation of gamma irradiation in the pharmaceutical development process. The summary therefore provides a useful reference to the application and versatility of gamma irradiation for pharmaceutical sterilization. Many pharmaceutical products require sterilization to ensure their safe and effective use. Sterility is therefore a critical quality attribute and is essential for direct injection products. Due to the requirement for terminal sterilization, where possible in the pharmaceutical industry sterilization by gamma irradiation has been commonly used as an effective method to sterilize pharmaceutical products as indicated by its acceptance in the European Pharmacopeia. Gamma sterilization is a very attractive terminal sterilization method in view of its ability to attain 10(-6) probability of microbial survival without excessive heating of the product or exposure to toxic chemicals. However, radiation compatibility of a product is one of the first aspects to evaluate when considering gamma sterilization. Gamma radiation consists of high-energy photons that result in the generation of free radicals and the subsequent ionization of chemical bonds, leading to cleavage of DNA in microorganisms and their subsequent inactivation. This can result in a loss of active pharmaceutical ingredient potency, the creation of radiolysis by-products, a reduction of the molecular weight of polymer excipients, and influence drug release from the final product. There are several strategies for mitigating degradation effects, including optimization of the irradiation dose and conditions. This review will serve to highlight the extensive application of gamma sterilization to a broad spectrum of pharmaceutical components including active pharmaceutical ingredients, excipients, final drug products, and combination drug-medical devices.

  1. Investigation of a sterilization system using active oxygen species generated by ultraviolet irradiation.

    PubMed

    Yoshino, Kiyoshi; Matsumoto, Hiroyuki; Iwasaki, Tatsuyuki; Kinoshita, Shinobu; Noda, Kazutoshi; Oya, Kei; Iwamori, Satoru

    2015-01-01

    We have been investigating an advanced sterilization system that employs active oxygen species (AOS). We designed the sterilization equipment, including an evacuation system, which generates AOS from pure oxygen gas using ultraviolet irradiation, in order to study the conditions necessary for sterilization in the system's chamber. Using Geobachillus stearothermophilus spores (10(6) CFU) in a sterile bag as a biological indicator (BI) in the chamber of the AOS sterilization apparatus, we examined the viability of the BI as a function of exposure time, assessing the role of the decompression level in the sterilization performance. We found that the survival curves showed exponential reduction, and that the decompression level did not exert a significant influence on the survival curve. Subsequently, we investigated the sterilization effect as influenced by the spatial and environmental temperature variation throughout the chamber, and found that the sterilization effect varied with position, due to the varying environmental temperature in the respective areas. We confirmed that temperature is one of the most important factors influencing sterilization in the chamber, and estimated the temperature effect on the distribution of atomic oxygen concentration, using the quartz crystal microbalance (QCM) method with fluorocarbon thin film prepared by radio frequency sputtering.

  2. Numerical approach to reference identification of Staphylococcus, Stomatococcus, and Micrococcus spp.

    PubMed

    Rhoden, D L; Hancock, G A; Miller, J M

    1993-03-01

    A numerical-code system for the reference identification of Staphylococcus species, Stomatococcus mucilaginosus, and Micrococcus species was established by using a selected panel of conventional biochemicals. Results from 824 cultures (289 eye isolate cultures, 147 reference strains, and 388 known control strains) were used to generate a list of 354 identification code numbers. Each six-digit code number was based on results from 18 conventional biochemical reactions. Seven milliliters of purple agar base with 1% sterile carbohydrate solution added was poured into 60-mm-diameter agar plates. All biochemical tests were inoculated with 1 drop of a heavy broth suspension, incubated at 35 degrees C, and read daily for 3 days. All reactions were read and interpreted by the method of Kloos et al. (G. A. Hebert, C. G. Crowder, G. A. Hancock, W. R. Jarvis, and C. Thornsberry, J. Clin. Microbiol. 26:1939-1949, 1988; W. E. Kloos and D. W. Lambe, Jr., P. 222-237, in A. Balows, W. J. Hansler, Jr., K. L. Herrmann, H. D. Isenberg, and H. J. Shadomy, ed., Manual of Clinical Microbiology, 5th ed., 1991). This modified reference identification method was 96 to 98% accurate and could have value in reference and public health laboratory settings.

  3. Reduction of antigenic protein levels in latex gloves after gamma irradiation.

    PubMed

    Zehr, B D; Gromelski, S; Beezhold, D

    1994-01-01

    Gamma irradiation is currently the method most commonly used to sterilize surgical gloves. In this study, the effect of gamma irradiation on antigenic proteins in latex gloves was examined. Protein extraction and quantitation were carried out using latex gloves before and after sterilization. Antigenic protein levels were determined by an ELISA assay specific for latex proteins (LEAP). LEAP analysis revealed a significant decrease after gamma-irradiation sterilization. This observation may partially explain the lower levels of extractable antigenic proteins found in sterile surgical gloves compared with nonsterile examination gloves. However, gamma irradiation was less effective than autoclave sterilization in reducing protein levels.

  4. STUDIES ON HOUSEFLIES, STERILIZED WITH X RAYS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sacca, G.

    1961-01-01

    Experiments were conducted on radiosterilization of male houseflies (Musca domestica). The females are monogamous, so that all the females mating with sterile males lay sterile eggs. Tests with 24-kv x rays showed that the most satisfactory method of sterilizing male houseflies consists of irradiating the pupa with 3000 r 2 to 3 days before emergence. The mortality of the irradiated pupae was not appreciably increased and the flies emerging from them were normal in appearance, viability, longevity, and sexual activity. When the irradiated males were mated with normal females, sterility was 100% complete. However, there was a slight tendency formore » females mated with irradiated males to remate with normal males. Sterile males successfully competed with normal males in search of females, and when they were present in overwhelming numbers succeeded in mating with most of the females, leaving them sterile. (H.H.D.)« less

  5. Racial variation in tubal sterilization rates: The role of patient-level factors

    PubMed Central

    Borrero, Sonya; Abebe, Kaleab; Dehlendorf, Christine; Schwarz, Eleanor Bimla; Creinin, Mitchell D.; Nikolajski, Cara; Ibrahim, Said

    2010-01-01

    Objective To assess racial differences in attitudes and knowledge about sterilization. Design Cross-sectional survey Setting Questionnaires were mailed to participants’ home addresses Patients 193 women aged 18–45 who had undergone tubal sterilization. Intervention(s) None Main Outcome Measure Attitudes and knowledge about tubal sterilization and awareness of contraceptive alternatives Results We received 193 completed surveys (64% response rate). AA woman were more likely to have a family member who had undergone tubal sterilization, to report that their mothers influenced their sterilization decisions, and to report that prior unintended pregnancy and desire to avoid insertion of a foreign object were very important factors in their decision to choose sterilization over other methods. Compared to white women, AA women more often thought that sterilization reversal could easily restore fertility (62 % vs 36%); that a woman’s sterilization would reverse itself after 5 years (60% vs 23%); and that a man cannot ejaculate after vasectomy (38% vs 13%). Fewer AA women had ever heard of intrauterine contraception (90% vs 98%). Racial differences in knowledge remained statistically significant after adjusting for socioeconomic confounders. Conclusions Misinformation about sterilization and limited awareness of contraceptive alternatives among AA women may contribute to racial disparities in tubal sterilization rates. PMID:20579640

  6. Plasma Sterilization: New Epoch in Medical Textiles

    NASA Astrophysics Data System (ADS)

    Senthilkumar, P.; Arun, N.; Vigneswaran, C.

    2015-04-01

    Clothing is perceived to be second skin to the human body since it is in close contact with the human skin most of the times. In hospitals, use of textile materials in different forms and sterilization of these materials is an essential requirement for preventing spread of germs. The need for appropriate disinfection and sterilization techniques is of paramount importance. There has been a continuous demand for novel sterilization techniques appropriate for use on various textile materials as the existing sterilization techniques suffer from various technical and economical drawbacks. Plasma sterilization is the alternative method, which is friendlier and more effective on the wide spectrum of prokaryotic and eukaryotic microorganisms. Basically, the main inactivation factors for cells exposed to plasma are heat, UV radiation and various reactive species. Plasma exposure can kill micro-organisms on a surface in addition to removing adsorbed monolayer of surface contaminants. Advantages of plasma surface treatment are removal of contaminants from the surface, change in the surface energy and sterilization of the surface. Plasma sterilization aims to kill and/or remove all micro-organisms which may cause infection of humans or animals, or which can cause spoilage of foods or other goods. This review paper emphasizes necessity for sterilization, essentials of sterilization, mechanism of plasma sterilization and the parameters influencing it.

  7. [The comparison of efficacy of female sterilization by modified Uchida technique and silver clips in China].

    PubMed

    Qiu, Hong-yan; Zou, Yan; Li, Li; Liang, Hong; Zhang, Hong-yan; Wu, Shang-chun

    2011-02-01

    To compare efficacy of female sterilization by modified Uchida technique and silver clips and to evaluate the influence on operation procedure and clinical effect with or without surgery training of service providers. A comparative, multicenter clinical trial was performed in 18 county and township-level service centers. Totally 2198 women underwent sterilization from these 18 study center were divided into 1116 women sterilized by modified Uchida technique and 1082 women by silver clips. Those 18 centers were classified into 9 training groups which provide surgical skills of sterilization and other contents and 9 non training groups. Clinical documents of sterilization were recorded. All women were follow-up at 3, 6 and 12 months after surgery. There were no complications during surgery by both sterilization. The failure rate was 2.03% (22/1082) in silver clip method and the mean operative time were (12.4 ± 6.4) minutes in training group and (14.4 ± 8.1) minutes in non training group. In modified Uchida method, the failure rate was 0.18% (2/1116) and the mean operative time were (16.2 ± 4.9) minutes in training group and (19.0 ± 8.6) minutes in non training group. The mean operative time between two groups reached statistical difference (all P < 0.05). Total ended rate in modified Uchida technique were 2.2/hundred women year in training group and 2.5/hundred women year in non training group, and the rate of silver slips were 3.9/hundred women year and 4.8/hundred women year, which did not show significant difference (all P > 0.05). There was no significant difference in acceptability and side effects of all women between two methods (P > 0.05). The training of service providers could influence acceptability of women (P < 0.05). Clinical efficacy was not influenced by those two methods. The operative time and acceptability were improved by training surgeons in silver clips method.

  8. Comparison of effectiveness of wood decay fungi maintained by annual subculture on agar and stored in sterile water for 18 years.

    PubMed

    Richter, Dana L; Kangas, Laura C; Smith, Jill K; Laks, Peter E

    2010-03-01

    Fourteen isolates of basidiomycete decay fungi (12 species) were maintained for 18 years on agar slants transferred annually and also stored as mycelium-agar cores under cold sterile water without subculture. Isolates stored by each method were evaluated for decay effectiveness using a standard laboratory accelerated soil-block decay test. Effectiveness was measured by mean percent mass loss of wood blocks. There was no significant difference (p < or = 0.05) in decay effectiveness between storage methods for 12 of the fungus isolates tested. For the 2 fungi that showed a significant difference in the amount of decay with respect to storage method, 1 fungus (Fomitopsis lilacinogilva) produced more decay by the strain maintained as an agar slant, while the other fungus (Trametes versicolor) produced more decay by the strain stored in sterile water. Results suggested that storage under sterile water is an easy and effective method to store isolates of decay fungi for long periods, but as with any microbial storage method, careful monitoring of isolates upon revival is necessary.

  9. Sterilization of fermentation vessels by ethanol/water mixtures

    DOEpatents

    Wyman, C.E.

    1999-02-09

    A method is described for sterilizing process fermentation vessels with a concentrated alcohol and water mixture integrated in a fuel alcohol or other alcohol production facility. Hot, concentrated alcohol is drawn from a distillation or other purification stage and sprayed into the empty fermentation vessels. This sterilizing alcohol/water mixture should be of a sufficient concentration, preferably higher than 12% alcohol by volume, to be toxic to undesirable microorganisms. Following sterilization, this sterilizing alcohol/water mixture can be recovered back into the same distillation or other purification stage from which it was withdrawn. The process of this invention has its best application in, but is not limited to, batch fermentation processes, wherein the fermentation vessels must be emptied, cleaned, and sterilized following completion of each batch fermentation process. 2 figs.

  10. [Possible Instrument Contamination in the Operating Room During Implantation of Knee and Hip Arthroplasty].

    PubMed

    Quint, U; Benen, T

    2016-04-01

    Integrated ventilation systems with low turbulence displacement flow (TAV) are generally legally required in the architectural structure of operating theatres. However, it seems that the instruments laid out on sterile covered tables do not have the best possible protection from bacteria. Within an operating theatre, different bacteria counts are possible on the instruments. This prospective controlled study was conducted to demonstrate the influence of instrument tables with integrated horizontal flow on contamination with pathogens in comparison with conventional tables. In an operating theatre (OT) with a ceiling legally appropriate for TAV (2.40 m × 1.20 m), microbiological samples were placed on a table with integrated TAV flow (n = 100) and on a conventional instrument table (n = 100). The routine qualification of the OT was on an ongoing basis and was in accordance with DIN 1946-4: 1999 standards (in accordance with DIN measurement of recovery time 1946-4: 12-2008). This corresponds to the OT of the room class Ib. The results show significant differences between the two tables. The bacteria count and the percentage of contamination were many times higher on the conventional table. It is important to understand that the instruments are not completely protected against contamination after opening the pack and during the operation. Remedial measures are possible to optimise the sterility the instrument table. Georg Thieme Verlag KG Stuttgart · New York.

  11. Supercritical carbon dioxide-based sterilization of decellularized heart valves.

    PubMed

    Hennessy, Ryan S; Jana, Soumen; Tefft, Brandon J; Helder, Meghana R; Young, Melissa D; Hennessy, Rebecca R; Stoyles, Nicholas J; Lerman, Amir

    2017-02-01

    The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile using histology, microbe culture and electron microscopy assays. The cusp tensile properties of supercritical carbon dioxide treated valves were higher compared to valves treated with other techniques. Superior sterility and integrity was found in the decellularized valves treated with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues.

  12. Soft-tissue allografts terminally sterilized with an electron beam are biomechanically equivalent to aseptic, nonsterilized tendons.

    PubMed

    Elenes, Egleide Y; Hunter, Shawn A

    2014-08-20

    Allograft safety is contingent on effective sterilization. However, current sterilization methods have been associated with decreased biomechanical strength and higher failure rates of soft-tissue allografts. In this study, electron beam (e-beam) sterilization was explored as an alternative sterilization method to preserve biomechanical integrity. We hypothesized that e-beam sterilization would not significantly alter the biomechanical properties of tendon allograft compared with aseptic, nonsterilized controls and gamma-irradiated grafts. Separate sets of forty fresh-frozen tibialis tendon allografts (four from each of ten donors) and forty bisected bone-patellar tendon-bone (BTB) allografts (four from each of ten donors) were randomly assigned to four study groups. One group received a 17.1 to 21.0-kGy gamma radiation dose; two other groups were sterilized with an e-beam at either a high (17.1 to 21.0-kGy) or low (9.2 to 12.2-kGy) dose. A fourth group served as nonsterilized controls. Each graft was cyclically loaded to 200 N of tension for 2000 cycles at a frequency of 2 Hz, allowed to relax for five minutes, and then tested in tension until failure at a 100%/sec strain rate. One-way analysis of variance testing was used to identify significant differences. Tibialis tendons sterilized with both e-beam treatments and with gamma irradiation exhibited values for cyclic tendon elongation, maximum load, maximum displacement, stiffness, maximum stress, maximum strain, and elastic modulus that were not significantly different from those of nonsterilized controls. BTB allografts sterilized with the high e-beam dose and with gamma irradiation were not significantly different in cyclic tendon elongation, maximum load, maximum displacement, stiffness, maximum stress, maximum strain, and elastic modulus from nonsterilized controls. BTB allografts sterilized with the e-beam at the lower dose were significantly less stiff than nonsterilized controls (p = 0.014) but did not differ from controls in any other properties. The difference in stiffness likely resulted from variations in tendon size rather than the treatments, as the elastic moduli of the groups were similar. The biomechanical properties of tibialis and BTB allografts sterilized with use of an e-beam at a dose range of 17.1 to 21.0 kGy were not different from those of aseptic, nonsterilized controls or gamma-irradiated allografts. E-beam sterilization can be a viable method to produce safe and biomechanically uncompromised soft-tissue allografts. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  13. A comparative study of female sterilization via modified Uchida and silver clip techniques in rural China.

    PubMed

    Qiu, Hongyan; Li, Li; Wu, Shangchun; Liang, Hong; Yuan, Wei; He, Yingqin

    2011-03-01

    To compare the specific effects of 2 female sterilization methods: the modified Uchida technique and the application of silver clips. A total of 2198 women living in rural areas who were still of reproductive age but opting for sterilization were enrolled. The participants were randomly divided into 2 groups, and underwent sterilization by either modified Uchida technique or silver clips. Information on acceptability, operation conditions, effectiveness, adverse effects, and complaints was collected 3, 6, and 12 months after the procedure. No significant difference in effectiveness, adverse effects or chief complaints between the 2 procedures was found. Differences in operative outcome, bleeding volume during the procedure, and operation time were found. A shorter operation time and less bleeding for the silver clip method indicated that female sterilization by this technique was as safe as that by modified Uchida technique. Copyright © 2010 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  14. A case of refractory chronic neutrophilic pustular folliculitis treated with adalimumab.

    PubMed

    Sand, Freja Laerke; Thomsen, Simon Francis

    2015-01-01

    Neutrophilic folliculitis is an often overlooked chronic condition characterized by a monomorphic eruption of "sterile" papulopustules. Neutrophilic folliculitis is often refractory to conventional treatment with topical and systemic antibiotics or isotretinoin. We report a case of severe pustular neutrophilic folliculitis successfully treated with the tumor necrosis factor-alpha inhibitor adalimumab. © 2014 Wiley Periodicals, Inc.

  15. Differences in the Access to Sterilization between Women Living and Not Living with HIV: Results from the GENIH Study, Brazil.

    PubMed

    Barbosa, Regina Maria; Cabral, Cristiane da Silva; do Lago, Tania di Giacomo; Pinho, Adriana de Araujo

    2016-01-01

    In many countries, young women of reproductive age have been especially affected by the HIV epidemic, which have fostered research to better understand how HIV infection influences and shapes women´s fertility and reproductive and sexual decisions. In Brazil, few studies have focused on the impact of the HIV epidemic on contraceptive choices among women living with HIV (WLHIV). This study evaluates the impact HIV infection may have in the access to female sterilization in Brazil, using a time-to-event analysis. A cross-sectional quantitative study (GENIH study) was conducted between February 2013 and April 2014 in the city of São Paulo, comparing two probabilistic samples of 975 WLHIV and 1,003 women not living with HIV (WNLHIV) aged 18 to 49. Sexual and reproductive data was collected retrospectively in order to reconstruct women's reproductive trajectories. Given the objectives of this study, the analysis was restricted to women with parity one or more and, in case of WLHIV, to those sterilized after HIV diagnosis and not infected through vertical transmission. The final sample analysis included 683 WNLHIV and 690 WLHIV. A series of multivariable-adjusted Cox models estimated the probability of being sterilized after HIV diagnosis, compared with WNLHIV. Models were adjusted for schooling, race/color, and stratified by parity at last delivery (1-2, 3+). Hazard ratios were calculated for female sterilization, and separately for interval and postpartum procedures (performed in conjunction with caesarean section or immediately after vaginal delivery). Additionally, information regarding unmet demand for female sterilization was also explored. No statistical difference in the overall risk of sterilization between WLHIV and WNLHIV in the two parity-related groups is observed: HR = 0.88 (0.54-1.43) and 0.94 (0.69-1.29), respectively, among women with 1-2 children and those with three and more. However, significant differences regarding the impact of HIV infection at sterilization are observed depending on the timing and the type of sterilization procedure. The probability of obtaining an interval sterilization is significantly lower for WLHIV compared to those not living with HIV. The reverse occurs regarding postpartum sterilization. Although sterilization is mainly performed in conjunction with caesarean section in Brazil, it is evident that caesarean sections are not the sole factor increasing the risk of sterilization among WLHIV. The results indicate barriers in the access to services offering interval sterilization for WLHIV and certain facilitation in obtaining the procedure in conjunction with caesarean section. Health policy makers at local and national levels should promote institutional changes in order to facilitate access to interval sterilization and to confront the sensitive discussion of WLHIV's eligibility for postpartum sterilization. It is also urgent to increase access to a wider range of contraceptive methods for WLHIV and promote dual method protection strategies. Moreover, since condom use may decrease in the future in the context of the preventive effect of antiretroviral therapy, promoting dual methods will expand the choices regarding the reproductive rights of women living with HIV.

  16. Far-UVC light applications: sterilization of MRSA on a surface and inactivation of aerosolized influenza virus

    NASA Astrophysics Data System (ADS)

    Welch, David; Buonanno, Manuela; Shuryak, Igor; Randers-Pehrson, Gerhard; Spotnitz, Henry M.; Brenner, David J.

    2018-02-01

    Methicillin-resistant Staphylococcus aureus (MRSA) and influenza A virus are two of the major targets for new antimicrobial technologies. In contrast to conventional germicidal lamps emitting primarily at 254 nm, which are both carcinogenic and cataractogenic, recent work has shown the potential of far-UVC technology, mainly between 207 and 222 nm, to be an effective means of sterilization of pathogens without apparent harm to mammalian cells. This is because, due to its strong absorbance in biological materials, far-UVC light cannot penetrate even the outer (non living) layers of human skin or eye; however, because bacteria and viruses are of micrometer or smaller dimensions, far-UVC can penetrate and inactivate them. With this report, we present progress on in vitro tests to inactivate MRSA on a surface using far-UVC light from a laser delivered using an optical diffuser. Qualitative and quantitative results show that this means of far-UVC exposure is adequate to inactivate MRSA with a dose comparable to that which would be required using a conventional germicidal lamp. Also included is a report on progress on inactivation of aerosolized influenza A virus. A custom benchtop aerosol exposure chamber was constructed and used to determine the effectiveness of far- UVC. Results indicate that far-UVC efficiently inactivates airborne aerosolized viruses, with a very low dose of 2 mJ/cm2 of 222-nm light inactivating >95% of aerosolized H1N1 influenza virus. Together these studies help to further establish far-UVC technology as a promising, safe and inexpensive tool for sterilization in many environments.

  17. Method of sterilization using ozone

    NASA Technical Reports Server (NTRS)

    Murphy, Oliver J. (Inventor); Hitchens, G. Duncan (Inventor)

    2002-01-01

    Methods of using ozone have been developed which sterilize instruments and medical wastes, oxidize, organics found in wastewater, clean laundry, break down contaminants in soil into a form more readily digested by microbes, kill microorganisms present in food products, and destroy toxins present in food products. The preferred methods for killing microorganism and destroying toxins use pressurized, humidified, and concentrated ozone produced by an electrochemical cell.

  18. Female sterilization is more common among women with physical and/or sensory disabilities than women without disabilities in the United States.

    PubMed

    Wu, Justine P; McKee, Michael M; Mckee, Kimberly S; Meade, Michelle A; Plegue, Melissa; Sen, Ananda

    2017-07-01

    Female sterilization accounts for 50% of all contraceptive use in the U.S. The extent to which U.S. women with physical and/or sensory disabilities have undergone female sterilization is unknown. Our primary objective was to determine the prevalence of sterilization for women with physical/sensory disabilities, and compare this to the prevalence for women without disabilities. We also compared use of long-acting reversible contraceptive (LARC) methods between women with and without disabilities. We conducted a secondary analysis of data from the National Survey of Family Growth 2011-2013, a population-based survey of U.S. women aged 15-44. Bivariate comparisons between women with and without disabilities by female sterilization and LARC use were conducted using chi-square tests. Using logistic regression, we estimated the odds of female sterilization based upon disability status. Women with physical/sensory disabilities accounted for 9.3% of the total sample (N = 4966). Among women with disabilities only, 28.2% had undergone female sterilization, representing 1.2 million women nationally. LARC use was lower among women with disabilities than those without disabilities (5.4%, 9.3%, respectively, p < 0.01). After adjusting for age, race/ethnicity, education, insurance, marital status, parity, and self-reported health, women with disabilities had higher odds of sterilization (OR 1.36, 95% CI 1.03, 1.79). The odds of female sterilization is higher among women with physical/sensory disabilities than those without disabilities. Future research is necessary to understand factors contributing to this finding, including possible underutilization of LARC methods. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. [Is female sterilization voluntary in El Salvador]?].

    PubMed

    Bertrand, J T; Landry, E G; Araya Zelaya, J D

    1986-01-01

    Sexual sterilization has become an increasingly important family planning method in developing countries, and notably so in Latin America, but some controversy has surrounded the practice because of the suggestion that individuals are coerced into undergoing sterilization. With the goal of examining allegations that low-income women in El Salvador are sterilized without their full knowledge or consent in family planning programs financed by the US, researchers interviewed 648 women who had received the operation in one of 7 facilities in El Salvador. In general, women were interviewed 1 month after their operation, by 6 trained female interviewers, with the assurance that the follow-up effort was not in any way connected with the facility performing the operation. An effort to sample approximately the same number of women from each facility was not entirely successful because of access difficulties. Most interviewees had been sterilized at below 30 years of age (average age at sterilization was 28 years), had begun having children in adolescence, and had not received more than a primary education. They had an average of 3.4 children and 1/3 had experienced the death of at least 1 child. The response to the survey indicated that female sterilization in El Salvador is voluntary. Women were shown to be aware of other contraception options. They had found out about sterilization and had become further informed about the method through providers and through communications with other women who had known about the operation at least 3 years before making a decision to submit to it, and many had waited between 1 month and 1 year before/between the decision and the actual operation. Only 1 women claimed to have felt pressured to be sterilized, identifying her mother as the source of the pressure.

  20. Cleaning of endodontic files, Part I: The effect of bioburden on the sterilization of endodontic files.

    PubMed

    Johnson, M A; Primack, P D; Loushine, R J; Craft, D W

    1997-01-01

    Ninety-two new endodontic files were randomly assigned to five groups with varying parameters of contamination, cleaning method, and sterilization (steam or chemical). Files were instrumented in bovine teeth to accumulate debris and a known contaminant, Bacillus stearothermophilus. Positive controls produced growth on both T-soy agar plates and in T-soy broth. Negative controls and experimental files (some with heavy debris) failed to produce growth. The results showed that there was no significant difference between contaminated files that were not cleaned before sterilization and contaminated files that were cleaned before sterilization. Bioburden present on endodontic files does not appear to affect the sterilization process.

  1. How and why women choose sterilization: results from six follow-up surveys.

    PubMed

    Landry, E

    1990-01-01

    Follow-up surveys were carried out in six countries (Bangladesh, Columbia, El Salvador, Guatemala, Indonesia, and Tunisia) between 1984 and 1986 to assess client decision-making regarding sterilization. The results revealed that women made well-informed, voluntary decisions to be sterilized. They were knowledgeable about other family planning methods and made the decision to be sterilized after consulting their partners, friends, relatives, or other sterilized women. Although their decisions were voluntary, other findings revealed areas for improvement such as client information and education about the risks of the procedure. These data were used to improve program services by emphasizing the need for better information, education, and counseling programs.

  2. Effectiveness of bilateral tubotubal anastomosis in a large outpatient population

    PubMed Central

    Berger, Gary S.; Thorp, John M.; Weaver, Mark A.

    2016-01-01

    STUDY QUESTION Is bilateral tubotubal anastomosis a successful treatment in an outpatient patient population? SUMMARY ANSWER For women wanting children after tubal sterilization, bilateral tubotubal anastomosis is an effective outpatient treatment. WHAT IS KNOWN ALREADY With the current emphasis in reproductive medicine on high technology procedures, the effectiveness of female surgical sterilization reversal is often overlooked. Previous clinical studies of tubal sterilization reversal have been mostly retrospective analyses of small patient populations. STUDY DESIGN, SIZE, DURATION A cohort of women who underwent outpatient bilateral tubotubal anastomosis from January 2000 to June 2013 was followed prospectively until December 2014 to determine the proportions of women undergoing the procedure who became pregnant and who had live births. Data were collected at the time of pregnancy. Differences in pregnancy rates and live birth rates associated with age, race and sterilization method were evaluated. PARTICIPANTS/MATERIALS, SETTING, METHODS A total of 6692 women, aged 20–51 years, underwent outpatient bilateral tubotubal anastomosis. MAIN RESULTS AND THE ROLE OF CHANCE The crude overall pregnancy rate was 69%. The crude overall birth rate was 35%. Results varied according to age at sterilization reversal and the method of sterilization. Women under 30 years of age at reversal of ring/clip sterilizations had an 88% pregnancy rate and 62% birth rate. Pregnancy and birth rates declined as age increased at sterilization reversal. Coagulation sterilization reversals resulted in the lowest rates of pregnancies and births. Ligation/resection reversals had intermediate success rates. LIMITATIONS, REASONS FOR CAUTION Limitations of our study include probable underreporting of pregnancies based on patient-initiated reports; possible errors in the reporting of pregnancies or early miscarriages that may have been based solely on home pregnancy tests; and probable over-reporting of the diagnosis of ectopic pregnancies. We identified age and sterilization method as being associated with subsequent pregnancy, however, in order to be considered predictive, the associations would need to be validated in an independent second prospectively studied group of representative patients. Finally, we also included patients in the study population who had additional surgical procedures performed at the time of tubotubal anastomosis (e.g. uterine myomectomy, fimbrioplasty, ovarian cystectomy and adhesiolysis), factors that could result in differences in pregnancy statistics in our study versus other patient populations. WIDER IMPLICATIONS OF THE FINDINGS The results of this study can help inform patients and clinicians about this low technology alternative to IVF. STUDY FUNDING/COMPETING INTEREST(S) None. TRIAL REGISTRATION NUMBER N/A. PMID:26980770

  3. Genetic basis of hybrid male sterility among three closely related species of Drosophila.

    PubMed

    Mishra, Paras Kumar; Singh, B N

    2005-05-01

    The genetic basis of hybrid male sterility among three closely related species, Drosophila bipectinata, D. parabipectinata and D. malerkotliana has been investigated by using backcross analysis methods. The role of Y chromosome, major hybrid sterility (MHS) genes (genetic factors) and cytoplasm (non-genetic factor) have been studied in the hybrids of these three species. In the species pair, bipectinata--parabipectinata, Y chromosome introgression of parabipectinata in the genomic background of bipectinata and the reciprocal Y chromosome introgression were unsuccessful as all males in second backcross generation were sterile. Neither MHS genes nor cytoplasm was found important for sterility. This suggests the involvement of X-Y, X-autosomes or polygenic interactions in hybrid male sterility. In bipectinata--malerkotliana and parabipectinata--malerkotliana species pairs, Y chromosome substitution in reciprocal crosses did not affect male fertility. Backcross analyses also show no involvement of MHS genes or cytoplasm in hybrid male sterility in these two species pairs. Therefore, X- autosome interaction or polygenic interaction is supposed to be involved in hybrid male sterility in these two species pairs. These findings also provide evidence that even in closely related species, genetic interactions underlying hybrid male sterility may vary.

  4. Heat-sterilized PD fluid blocks leukocyte adhesion and increases flow velocity in rat peritoneal venules.

    PubMed

    Jonasson, P; Bagge, U; Wieslander, A; Braide, M

    1996-01-01

    Data from cell culture experiments indicate that heat sterilization of peritoneal dialysis (PD) fluids produces cytotoxic glucose degradation products. The present vital microscopic study investigated the effects of different sterilization methods on the biocompatibility of PD fluids. Thus, heat-sterilized (commercially obtained and experimentally produced) and filter-sterilized PD fluids (pH = 5.30-5.40; 1.5% glucose) were compared with Tyrode buffer, with respect to the effects on microvascular blood flow velocity and leukocyte adhesion in the rat mesentery. Exteriorization of the mesentery produced a mild inflammation, known from the literature and characterized by the adhesive rolling of leukocytes along venular walls. Superfusion of the mesentery with filter-sterilized PD fluid had no significant effects on leukocyte rolling or flow velocity in venules 25-40 microns in diameter compared with buffer superfusion. Heat-sterilized PD fluid decreased the concentration of rolling leukocytes and increased flow velocity significantly, as compared with buffer and filter-sterilized PD fluid. The results indicate that heat sterilization of PD fluids produces substances that interact with microvascular tone and leukocyte-endothelial adhesion, which hypothetically could impair the acute, granulocyte-mediated defense against bacterial infections.

  5. Reason behind wet pack after steam sterilization and its consequences: An overview from Central Sterile Supply Department of a cancer center in eastern India.

    PubMed

    Basu, Debabrata

    Wet pack after steam sterilization process that means there are surely obtain millions of microorganisms that can breed and multiply rapidly and objects are unsterile and can never be used for further procedure. There are many reasons behind the wet pack occurrences after autoclaving like poor quality of wrapping materials, faulty valves of rigid container, faulty loading and packaging technique, poor steam quality, sterilizer malfunction and may be design related problems in CSSD sterile storage area. Cause of wet pack after steam sterilization processes may occur severe problems because of wasted time and effort, increased work load, increased cost, potentially contaminated instruments, infection risk to the patient, poor patient outcomes and delayed or cancellation of procedures. But such wet pack scenario can be avoided by various methods by using good steam (water) quality, performing periodic maintenance of the Autoclaves, avoidance of sterilizer overloading, allowing adequate post sterilization time to cool down the materials to room temperature, using good quality wrapping materials, properly maintain temperature and humidity of sterile storage area etc. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  6. Effect of Abiotic Factors on Degradation of Imidacloprid.

    PubMed

    Mahapatra, Bibhab; Adak, Totan; Patil, Naveen K B; Pandi, G Guru P; Gowda, G Basana; Yadav, Manoj Kumar; Mohapatra, S D; Rath, P C; Munda, Sushmita; Jena, Mayabini

    2017-10-01

    The role of soil moisture, light and pH on imidacloprid dissipation was investigated. A high performance liquid chromatography (HPLC) based method was developed to quantify imidacloprid present in soil with a recovery of more than 82%. Rate of dissipation of imidacloprid from soil was faster in submerged condition compared to field capacity and air dried condition. Imidacloprid dissipated non-significantly between sterile and non-sterile soils, but at field capacity, the dissipation was faster in non-sterile soil compared to sterile soil after 60 days of incubation. Similarly, under submergence, the dissipation of imidacloprid was 66.2% and 79.8% of the initial in sterile and non-sterile soils, respectively. Imidacloprid was rather stable in acidic and neutral water but was prone to photo-degradation. Therefore, imidacloprid degradation will be faster under direct sunlight and at higher soil moisture.

  7. Application of Extended Kalman Filter in Persistant Scatterer Interferometry to Enhace the Accuracy of Unwrapping Process

    NASA Astrophysics Data System (ADS)

    Tavakkoli Estahbanat, A.; Dehghani, M.

    2017-09-01

    In interferometry technique, phases have been modulated between 0-2π. Finding the number of integer phases missed when they were wrapped is the main goal of unwrapping algorithms. Although the density of points in conventional interferometry is high, this is not effective in some cases such as large temporal baselines or noisy interferograms. Due to existing noisy pixels, not only it does not improve results, but also it leads to some unwrapping errors during interferogram unwrapping. In PS technique, because of the sparse PS pixels, scientists are confronted with a problem to unwrap phases. Due to the irregular data separation, conventional methods are sterile. Unwrapping techniques are divided in to path-independent and path-dependent in the case of unwrapping paths. A region-growing method which is a path-dependent technique has been used to unwrap PS data. In this paper an idea of EKF has been generalized on PS data. This algorithm is applied to consider the nonlinearity of PS unwrapping problem as well as conventional unwrapping problem. A pulse-pair method enhanced with singular value decomposition (SVD) has been used to estimate spectral shift from interferometric power spectral density in 7*7 local windows. Furthermore, a hybrid cost-map is used to manage the unwrapping path. This algorithm has been implemented on simulated PS data. To form a sparse dataset, A few points from regular grid are randomly selected and the RMSE of results and true unambiguous phases in presented to validate presented approach. The results of this algorithm and true unwrapped phases were completely identical.

  8. A comparative study of ethylene oxide gas, hydrogen peroxide gas plasma, and low-temperature steam formaldehyde sterilization.

    PubMed

    Kanemitsu, Keiji; Imasaka, Takayuki; Ishikawa, Shiho; Kunishima, Hiroyuki; Harigae, Hideo; Ueno, Kumi; Takemura, Hiromu; Hirayama, Yoshihiro; Kaku, Mitsuo

    2005-05-01

    To compare the efficacies of ethylene oxide gas (EOG), hydrogen peroxide gas plasma (PLASMA), and low-temperature steam formaldehyde (LTSF) sterilization methods. The efficacies of EOG, PLASMA, and LTSF sterilization were tested using metal and plastic plates, common medical instruments, and three process challenge devices with narrow lumens. All items were contaminated with Bacillus stearothermophilus spores or used a standard biological indicator. EOG and LTSF demonstrated effective killing of B. stearothermophilus spores, with or without serum, on plates, on instruments, and in process challenge devices. PLASMA failed to adequately sterilize materials on multiple trials in several experiments, including two of three plates, two of three instruments, and all process challenge devices. Our results suggest that PLASMA sterilization may be unsuccessful under certain conditions, particularly when used for items with complex shapes and narrow lumens. Alternatively, LTSF sterilization demonstrates excellent efficacy and is comparable to EOG sterilization. LTSF could potentially act as a substitute if EOG becomes unavailable due to environmental concerns.

  9. On the difficulties of discriminating between major and minor hybrid male sterility factors in Drosophila by examining the segregation ratio of sterile and fertile sons in backcrossing experiments.

    PubMed

    Maside, X R; Naveira, H F

    1996-10-01

    The observation of segregation ratios of sterile and fertile males in offspring samples from backcrossed hybrid females is, in principle, a valid method to unveil the genetic basis of hybrid male sterility in Drosophila. When the female parent is heterozygous (hybrid) for a sterility factor with major effects, equal proportions of fertile and sterile sons are expected in her offspring. However, intact (not recombined) chromosome segments of considerable length are expected to give segregation ratios that can not be easily differentiated from the 1:1 ratio expected from a single factor. When the phenotypic character under analysis can be determined by combinations of minor factors from the donor species spanning a certain chromosome length, very large offspring samples may be needed to test this alternative hypothesis against the null hypothesis of a single major factor. This is particularly the case of hybrid male sterility determinants in Drosophila.

  10. The Rise of Female Sterilization: A Closer Look at Colombia.

    PubMed

    Folch, Beatriz M; Betstadt, Sarah; Li, Dongmei; Whaley, Natalie

    2017-09-01

    Objective In the 1970s, OCPs and IUDs were the most popular contraceptive methods in Colombia. According to data from the most recent Demographic and Health Survey (DHS), sterilization has become the most common form of birth control in Colombia. This study aims to examine the characteristics of Colombian women desiring long-acting contraception. Methods This study uses the 2005 and 2010 Colombian DHS dataset. Women who choose long-acting contraception were divided into those using female sterilization and those using long-acting reversible contraception (LARC). A multivariate logistic regression model was used to compare demographic and social determinants of contraceptive choice among reproductive age women seeking long-acting contraception between the years 2005 and 2010. Results Among women using a long-acting contraceptive method in 2010, compared to 2005, women were significantly more likely to be sterilized (1.14 OR, 95% CI 1.09-1.18) and less likely to use LARC (0.88 OR, 95% CI 0.85-0.92). Of women seeking long-acting contraception, those exposed to a family planning provider were less likely to undergo sterilization (0.54 OR, 95% CI 0.51-0.58) and more likely to use LARC (1.84 OR, 95% CI 1.73-1.96). When compared to all contraceptive users, younger women and women with less than two children were more likely to use LARC than sterilization. Conclusion Between 2005 and 2010, an increase in the proportion of contracepting women being sterilized in Colombia occurred. Our findings suggest that exposure to a family planning provider and appropriate contraceptive counseling appears to be key determinants of long-acting contraceptive choice. To improve use of long-acting, effective contraception, efforts should be made to increase access to family planning providers.

  11. Vaporous Decontamination Methods: Potential Uses and Research Priorities for Chemical and Biological Contamination Control

    DTIC Science & Technology

    2006-06-01

    Decontamination assessment of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surfaces using a hydrogen...resistant to commonly used disinfectants and require the use of chemical sterilants † to effectively decontaminate exposed areas. Since anthrax...spores can aerosolise the use of vaporous sterilants in the remediation of contaminated areas is desirable. A number of vaporous sterilants exist which

  12. Rugged Ozone Sterilization System Model M1 (ROSS M1)

    DTIC Science & Technology

    2017-07-13

    water consumption , power requirements, and reliability). Special Forces personnel would benefit from the advantages of modern technology with the...chemical, heat, and radiation sterilization methods. At the end of the sterilization cycle, ozone and VHP are converted into oxygen and water vapor...chamber (Figure 7) was built to evaluate device operation over a range of environmental conditions ( temperature , humidity, pressure). Each component

  13. Japan Report, Science and Technology.

    DTIC Science & Technology

    1987-04-28

    manufacture liquid hydrogen domestically because "a method to manufacture hydrogen by decomposing methanol is in commercial use and if we neglect this area...system or element, and how safety is related to materials, production methods , and sterilization. The environment where the materials are used...be essential to produce them in a clean environment. For instance, the dialyzer-sterilizing method is changing. Initially, it was sold in

  14. Experiences using IAEA Code of practice for radiation sterilization of tissue allografts: Validation and routine control

    NASA Astrophysics Data System (ADS)

    Hilmy, N.; Febrida, A.; Basril, A.

    2007-11-01

    Problems of tissue allografts in using International Standard (ISO) 11137 for validation of radiation sterilization dose (RSD) are limited and low numbers of uniform samples per production batch, those are products obtained from one donor. Allograft is a graft transplanted between two different individuals of the same species. The minimum number of uniform samples needed for verification dose (VD) experiment at the selected sterility assurance level (SAL) per production batch according to the IAEA Code is 20, i.e., 10 for bio-burden determination and the remaining 10 for sterilization test. Three methods of the IAEA Code have been used for validation of RSD, i.e., method A1 that is a modification of method 1 of ISO 11137:1995, method B (ISO 13409:1996), and method C (AAMI TIR 27:2001). This paper describes VD experiments using uniform products obtained from one cadaver donor, i.e., cancellous bones, demineralized bone powders and amnion grafts from one life donor. Results of the verification dose experiments show that RSD is 15.4 kGy for cancellous and demineralized bone grafts and 19.2 kGy for amnion grafts according to method A1 and 25 kGy according to methods B and C.

  15. Sanitizer Efficacy against Murine Norovirus, a Surrogate for Human Norovirus, on Stainless Steel Surfaces when Using Three Application Methods

    PubMed Central

    Kotwal, Grishma; Harrison, Mark A.; Law, S. Edward; Harrison, Judy A.

    2013-01-01

    Human noroviruses are major etiologic agents of epidemic gastroenteritis. Outbreaks are often accompanied by contamination of environmental surfaces, but since these viruses cannot be routinely propagated in laboratory cultures, their response to surface disinfectants is predicted by using surrogates, such as murine norovirus 1 (MNV-1). This study compared the virucidal efficacies of various liquid treatments (three sanitizer liquids, 5% levulinic acid plus 2% SDS [LEV/SDS], 200 ppm chlorine, and an isopropanol-based quaternary ammonium compound [Alpet D2], and two control liquids, sterile tap water and sterile tap water plus 2% SDS) when delivered to MNV-1-inoculated stainless steel surfaces by conventional hydraulic or air-assisted, induction-charged (AAIC) electrostatic spraying or by wiping with impregnated towelettes. For the spray treatments, LEV/SDS proved effective when applied with hydraulic and AAIC electrostatic spraying, providing virus reductions of 2.71 and 1.66 log PFU/ml, respectively. Alpet D2 provided a 2.23-log PFU/ml reduction with hydraulic spraying, outperforming chlorine (1.16-log PFU/ml reduction). Chlorine and LEV/SDS were equally effective as wipes, reducing the viral load by 7.05 log PFU/ml. Controls reduced the viral load by <1 log with spraying applications and by >3 log PFU/ml with wiping. Results indicated that both sanitizer type and application methods should be carefully considered when choosing a surface disinfectant to best prevent and control environmental contamination by noroviruses. PMID:23263949

  16. Production of recombinant adeno-associated vectors using two bioreactor configurations at different scales

    PubMed Central

    Negrete, Alejandro; Kotin, Robert M.

    2007-01-01

    The conventional methods for producing recombinant adeno-associated virus (rAAV) rely on transient transfection of adherent mammalian cells. To gain acceptance and achieve current good manufacturing process (cGMP) compliance, clinical grade rAAV production process should have the following qualities: simplicity, consistency, cost effectiveness, and scalability. Currently, the only viable method for producing rAAV in large-scale, e.g.≥1016 particles per production run, utilizes Baculovirus Expression Vectors (BEVs) and insect cells suspension cultures. The previously described rAAV production in 40 L culture using a stirred tank bioreactor requires special conditions for implementation and operation not available in all laboratories. Alternatives to producing rAAV in stirred-tank bioreactors are single-use, disposable bioreactors, e.g. Wave™. The disposable bags are purchased pre-sterilized thereby eliminating the need for end-user sterilization and also avoiding cleaning steps between production runs thus facilitating the production process. In this study, rAAV production in stirred tank and Wave™ bioreactors was compared. The working volumes were 10 L and 40 L for the stirred tank bioreactors and 5 L and 20 L for the Wave™ bioreactors. Comparable yields of rAAV, ~2e+13 particles per liter of cell culture were obtained in all volumes and configurations. These results demonstrate that producing rAAV in large scale using BEVs is reproducible, scalable, and independent of the bioreactor configuration. Keywords: adeno-associated vectors; large-scale production; stirred tank bioreactor; wave bioreactor; gene therapy. PMID:17606302

  17. Survey of Sterile Admixture Practices in Canadian Hospital Pharmacies: Part 1. Methods and Results

    PubMed Central

    Warner, Travis; Nishi, Cesilia; Checkowski, Ryan; Hall, Kevin W.

    2009-01-01

    Background: The 1996 Guidelines for Preparation of Sterile Products in Pharmacies of the Canadian Society of Hospital Pharmacists (CSHP) represent the current standard of practice for sterile compounding in Canada. However, these guidelines are practice recommendations, not enforceable standards. Previous surveys of sterile compounding practices have shown that actual practice deviates markedly from voluntary practice recommendations. In 2004, the United States Pharmacopeia (USP) published its “General Chapter <797> Pharmaceutical Compounding—Sterile Preparations”, which set a more rigorous and enforceable standard for sterile compounding in the United States. Objectives: To assess sterile compounding practices in Canadian hospital pharmacies and to compare them with current CSHP recommendations and USP chapter <797> standards. Methods: An online survey, based on previous studies of sterile compounding practices, the CSHP guidelines, and the chapter <797> standards, was created and distributed to 193 Canadian hospital pharmacies. Results: A total of 133 pharmacies completed at least part of the survey, for a response rate of 68.9%. All respondents reported the preparation of sterile products. Various degrees of deviation from the practice recommendations were noted for virtually all areas of the CSHP guidelines and the USP standards. Low levels of compliance were most notable in the areas of facilities and equipment, process validation, and product testing. Availability in the central pharmacy of a clean room facility meeting or exceeding the criteria of International Organization for Standardization (ISO) class 8 is a requirement of the chapter <797> standards, but more than 40% of responding pharmacies reported that they did not have such a facility. Higher levels of compliance were noted for policies and procedures, garbing requirements, aseptic technique, and handling of hazardous products. Part 1 of this series reports the survey methods and results relating to policies, personnel, raw materials, storage and handling, facilities and equipment, and garments. Part 2 will report results relating to preparation of aseptic products, expiry dating, labelling, process validation, product testing and release, documentation, records, and disposal of hazardous pharmaceuticals. It will also highlight some of the key areas where there is considerable opportunity for improvement. Conclusion: This survey identified numerous deficiences in sterile compounding practices in Canadian hospital pharmacies. Awareness of these deficiencies may create an impetus for critical assessment and improvements in practice. PMID:22478875

  18. 9 CFR 109.1 - Equipment and the like.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AGRICULTURE VIRUSES, SERUMS, TOXINS, AND ANALOGOUS PRODUCTS; ORGANISMS AND VECTORS STERILIZATION AND... temperature of at least 160 °C. for not less than one hour. If for any reason such methods of sterilization...

  19. General Theories of Chemical Disinfection and Sterilization of Sludge--Part 3.

    ERIC Educational Resources Information Center

    Wang, Mu Hao; And Others

    1978-01-01

    A general discussion of sewage sterilization methods, including techniques using pH, Chlorine, Chlorine Dioxide, Ozone, Iodine and Bromine, metal ions, and cationic surface active agents is presented. (MDR)

  20. Public Law No. 101-167 of 21 November 1989, Foreign Operations, Export Financing, and Related Programs Appropriations Act, 1990.

    PubMed

    1989-01-01

    Among other things, this US Act makes appropriations for foreign operations, export financing, and related programs. With respect to these appropriations, it does the following: 1) prohibits funding for coercive abortion or forced sterilization as part of bilateral development and population planning assistance; 2) prohibits the use of funds appropriated under the Act to lobby for abortion; and 3) prohibits the use of development assistance funds to pay for abortions or involuntary sterilizations as a method of family planning or to motivate or coerce any persons to practice abortions or undergo sterilization, or any biomedical research concerning abortions or involuntary sterilization as a method of family planning. The Act also reaffirms the congressional commitment to population planning, development assistance, and the need for informed voluntary family planning.

  1. Search for heavy sterile neutrinos in trileptons at the LHC

    NASA Astrophysics Data System (ADS)

    Dib, Claudio O.; Kim, C. S.; Wang, Kechen

    2017-10-01

    We present a search strategy for both Dirac and Majorana sterile neutrinos from the purely leptonic decays of W± → e± e± μ∓ ν and μ± μ± e∓ ν at the 14 TeV LHC. The discovery and exclusion limits for sterile neutrinos are shown using both the Cut-and-Count (CC) and Multi-Variate Analysis (MVA) methods. We also discriminate between Dirac and Majorana sterile neutrinos by exploiting a set of kinematic observables which differ between the Dirac and Majorana cases. We find that the MVA method, compared to the more common CC method, can greatly enhance the discovery and discrimination limits. Two benchmark points with sterile neutrino mass m N = 20 GeV and 50 GeV are tested. For an integrated luminosity of 3000 fb-1, sterile neutrinos can be found with 5σ significance if heavy-to-light neutrino mixings |U Ne |2 ˜ |U Nμ |2˜ 10-6, while Majorana vs. Dirac discrimination can be reached if at least one of the mixings is of order 10-5. K. W. was Supported by the International Postdoctoral Exchange Fellowship Program (No.90 Document of OCPC, 2015); C. S. K. by the NRF grant funded by the Korean government of the MEST (No. 2016R1D1A1A02936965); and C. D. by Chile grants Fondecyt No. 1130617, Conicyt ACT 1406 and PIA/Basal FB0821

  2. CURRENT STATUS OF APPLICATIONS IN THE PASTEURIZATION OF STERILIZATION OF FOODS BY IONIZING RADIATIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kraybill, H.F.

    1960-04-01

    A comprehensive research and development program on radiation preservation of foods has revealed some products having potential for early commercialization. Radiation sterilization of some meats, especially beef, has been somewhat disappointing. Other items such as chicken, fish, and pork products show promise as completely sterile products. Surveys of the food industry have been made on these items but lack of a competitive position. radiation processing costs higher than thermal processing, and lack of Food & Drug clearance at this time have held up an immediate commercial advance in this area. Radiopasteurization currently, however, offers raore promise since effect on qualitymore » (flavor, texture. and color) is not encountered and processing cost now approaches that of conventional processing methods. Extension of shelf life, by radiopasteurization of fish, chicken, pork, and beef, is ready for industry- wide exploitation when Food & Drug clearance is provided. Elimination of parasites in meat by very-low dose treatment such as trichina in perk and tapeworm in beef has current interest in industry and may be the first industrial application. The wholesomeness clearance studies are progressing successfully with no evidence that would indicate any toxicity prevailing from eating irradiated foods in tests on animals and man. The ultimate development of " ionizing radiation centers" will advance radiation applications in the food industry since appraisal of performance and costs can be more satisfactorily made than in laboratory projects. Reduction in costs of gamma radiation sources should also hold much promise for a preferential competitive position for low- dose radiation treatment of meats, fruits, and vegetables. The unique opportunities afforded by radiation processing of foods in underdeveloped countries for reduction in food spoilage and waste and elimination of food poisoning are of current and immediate importance. (auth)« less

  3. Improvement of Biological Indicators by Uniformly Distributing Bacillus subtilis Spores in Monolayers To Evaluate Enhanced Spore Decontamination Technologies

    PubMed Central

    Raguse, Marina; Fiebrandt, Marcel; Stapelmann, Katharina; Madela, Kazimierz; Laue, Michael; Lackmann, Jan-Wilm; Thwaite, Joanne E.; Setlow, Peter; Awakowicz, Peter

    2016-01-01

    Novel decontamination technologies, including cold low-pressure plasma and blue light (400 nm), are promising alternatives to conventional surface decontamination methods. However, the standardization of the assessment of such sterilization processes remains to be accomplished. Bacterial endospores of the genera Bacillus and Geobacillus are frequently used as biological indicators (BIs) of sterility. Ensuring standardized and reproducible BIs for reliable testing procedures is a significant problem in industrial settings. In this study, an electrically driven spray deposition device was developed, allowing fast, reproducible, and homogeneous preparation of Bacillus subtilis 168 spore monolayers on glass surfaces. A detailed description of the structural design as well as the operating principle of the spraying device is given. The reproducible formation of spore monolayers of up to 5 × 107 spores per sample was verified by scanning electron microscopy. Surface inactivation studies revealed that monolayered spores were inactivated by UV-C (254 nm), low-pressure argon plasma (500 W, 10 Pa, 100 standard cubic cm per min), and blue light (400 nm) significantly faster than multilayered spores were. We have thus succeeded in the uniform preparation of reproducible, highly concentrated spore monolayers with the potential to generate BIs for a variety of nonpenetrating surface decontamination techniques. PMID:26801572

  4. THE POSSIBLE USE OF IONIZING RADIATION FOR THE STERILIZATION OF CERTAIN BIOLOGICAL PREPARATIONS. I. THE INFLUENCE OF IONIZING RADIATION UPON GAS-GANGRENE AND TETANUS ANTI-SERUM (SEROLOGICAL AND ELECTROPHORETIC INVESTIGATION)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goncharenko, I.M.

    1961-12-01

    The antltoxic properties and the relative proportion of the protein fractions of gas-gangrene and tetanus antisera were studied. The results show that the sterilization of dried antisera with gamma rays caused no marked decrease in the antitoxin titre. Similar results were obtained with liquid antisera containing 0.3% mercamine. However, crude and concentrated liquid antisera after sterilization by radiation showed a marked decrease in antitoxin titre. Under the usual conditions, sterilization of liquid antisera appears to be inadvsable, not-withstanding the simpliclty, convenience, and reliabillty of the method; sterilization of dried antisera, however, offers better prospects. (P. C.H.)

  5. Characteristics of surface sterilization using electron cyclotron resonance plasma

    NASA Astrophysics Data System (ADS)

    Yonesu, Akira; Hara, Kazufumi; Nishikawa, Tatsuya; Hayashi, Nobuya

    2016-07-01

    The characteristics of surface sterilization using electron cyclotron resonance (ECR) plasma were investigated. High-energy electrons and oxygen radicals were observed in the ECR zone using electric probe and optical emission spectroscopic methods. A biological indicator (BI), Geobacillus stearothermophilus, containing 1 × 106 spores was sterilized in 120 s by exposure to oxygen discharges while maintaining a temperature of approximately 55 °C at the BI installation position. Oxygen radicals and high-energy electrons were found to be the sterilizing species in the ECR region. It was demonstrated that the ECR plasma could be produced in narrow tubes with an inner diameter of 5 mm. Moreover, sterilization tests confirmed that the spores present inside the narrow tube were successfully inactivated by ECR plasma irradiation.

  6. Research to support sterile-male-release and genetic alteration techniques for sea lamprey control

    USGS Publications Warehouse

    Bergstedt, Roger A.; Twohey, Michael B.

    2007-01-01

    Integrated pest management of sea lampreys in the Laurentian Great Lakes has recently been enhanced by addition of a sterile-male-release program, and future developments in genetic approaches may lead to additional methods for reducing sea lamprey reproduction. We review the development, implementation, and evaluation of the sterile-male-release technique (SMRT) as it is being applied against sea lampreys in the Great Lakes, review the current understanding of SMRT efficacy, and identify additional research areas and topics that would increase either the efficacy of the SMRT or expand its geographic potential for application. Key areas for additional research are in the sterilization process, effects of skewed sex ratios on mating behavior, enhancing attractiveness of sterilized males, techniques for genetic alteration of sea lampreys, and sources of animals to enhance or expand the use of sterile lampreys.

  7. Post-sterilization autonomy among young mothers in South India.

    PubMed

    Pallikadavath, Saseendran; Rajan, Irudaya; Singh, Abhishek; Ogollah, Reuben; Page, Samantha

    2015-01-01

    This study examined the post-sterilization autonomy of women in south India in the context of early sterilization and low fertility. Quantitative data were taken from the third round of the National Family Health Survey (NFHS-3) carried out in 2005-06, and qualitative data from one village each in Kerala and Tamil Nadu during 2010-11. The incident rate ratios and thematic analysis showed that among currently married women under the age of 30 years, those who had been sterilized had significantly higher autonomy in household decision-making and freedom of mobility compared with women who had never used any modern family planning method. Early age at sterilization and low fertility enables women to achieve the social status that is generally attained at later stages in the life-cycle. Policies to capitalize on women's autonomy and free time resulting from early sterilization and low fertility should be adopted in south India.

  8. Pest persistence and eradication conditions in a deterministic model for sterile insect release.

    PubMed

    Gordillo, Luis F

    2015-01-01

    The release of sterile insects is an environment friendly pest control method used in integrated pest management programmes. Difference or differential equations based on Knipling's model often provide satisfactory qualitative descriptions of pest populations subject to sterile release at relatively high densities with large mating encounter rates, but fail otherwise. In this paper, I derive and explore numerically deterministic population models that include sterile release together with scarce mating encounters in the particular case of species with long lifespan and multiple matings. The differential equations account separately the effects of mating failure due to sterile male release and the frequency of mating encounters. When insects spatial spread is incorporated through diffusion terms, computations reveal the possibility of steady pest persistence in finite size patches. In the presence of density dependence regulation, it is observed that sterile release might contribute to induce sudden suppression of the pest population.

  9. Autoclave sterilization of instruments used on women with cervical neoplasia is an effective method of eradicating residual human papillomavirus DNA: a polymerase chain reaction-based evaluation.

    PubMed

    Estes, Jacob M; Kirby, Tyler O; Huh, Warner K

    2007-01-01

    To determine whether autoclave sterilization eradicates human papillomavirus (HPV) DNA on specula and instruments used to treat women with cervical neoplasia. Specula and instruments used in two referral colposcopy clinics were evaluated to determine the PGMY9/11 primer system's ability to amplify residual HPV DNA. Each speculum and instrument was sampled with a Dacron swab and stored in PreservCyt solution (Cytyc Corporation, Marlborough, MA) at 4 degrees C. DNA amplification was performed under standard conditions with appropriate controls followed by HPV typing using the reverse line blot test (Roche Molecular Systems, Alameda, CA). Once validated, the same polymerase chain reaction method was used on autoclave-sterilized specula and biopsy instruments and heated glass bead- and Cidex bath (Johnson & Johnson, New Brunswick, NJ)-sterilized instruments. All results, with appropriate positive and negative controls, were confirmed in triplicate. A total of 140 instruments (70 used and 70 autoclaved) were sampled for residual HPV DNA. Five samples in the contaminated specula arm were excluded from analysis secondary to insufficient sampling. Of the remaining samples, 52.3% (34/65) of contaminated instruments-both specula and biopsy instruments-had detectable HPV DNA. Fifty-five percent of contaminated biopsy instruments (11/20) were positive and 51.1% of contaminated specula (23/45) were positive. All 70 autoclaved samples (50 specula and 20 biopsy instruments) were negative for residual HPV DNA or beta-globin. One instrument in the glass bead and Cidex group that was presumed sterile was positive for HPV 16 DNA. The PGMY9/11 primer system is an effective method to detect residual HPV DNA. Autoclave sterilization appears to eradicate HPV DNA to levels undetectable with this sensitive assay, whereas heated glass beads followed by Cidex bath appears to be inadequate methods. These results suggest that autoclave sterilization is effective when using nondisposable instruments and should be the method of choice in studies using polymerase chain reaction-based amplification of HPV DNA.

  10. Effects of Sterilization on the Physico-Chemical Properties of Natural Sediments From the Oak Ridge Reservation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bank, T.L.; Kukkadapu, R.K.; Madden, A.S.

    2009-04-29

    Batch U(VI) sorption/reduction experiments were completed on sterilized and non-sterilized sediment samples to elucidate biological and geochemical reduction mechanisms. Results from X-ray absorption near-edge structure (XANES) spectroscopy revealed that {gamma}-sterilized sediments were actually better sorbents of U(VI), despite the absence of any measurable biological activity. These results indicate that {gamma}-irradiation induced significant physico-chemical changes in the sediment which is contrary to numerous other studies identifying {gamma}-sterilization as an effective and minimally invasive technique. To identify the extent and method of alteration of the soil as a result of {gamma}-sterilization, untreated soil samples, physically separated size fractions, and chemically extracted fractionsmore » of the soil were analyzed pre- and post-sterilization. The effects of sterilization on mineralogy, pH, natural organic matter (NOM), cation exchange capacity (CEC), and iron oxidation state were determined. Results indicated that major mineralogy of the clay and whole sediment samples was unchanged. Sediment pH decreased only slightly with {gamma}-irradiation; however, irradiation produced a significant decrease in CEC of the untreated sediments and affected both the organic and inorganic fractions. Moessbauer spectra of non-sterile and {gamma}-sterilized sediments measured more reduced iron present in {gamma}-sterilized sediments compared to non-sterile samples. Our results suggest that sterilization by {gamma}-irradiation induced iron reduction that may have increased the sorption and/or reduction of U(VI) onto these sediments. However, Moessbauer and batch sorption data are somewhat contradictory, the former indicates that the iron oxide or iron hydroxide minerals are more significantly reduced while the later indicates that reduced clay minerals account for greater sorption of U(VI).« less

  11. Effects of gamma-sterilization on the physicochemical properties of natural sediments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bank, Tracy L; Madden, Andrew; Baldwin, Mark E

    2008-06-01

    Batch U(VI) sorption/reduction experiments were completed on sterilized and non-sterilized sediment samples to elucidate biological and geochemical reduction mechanisms. Results from X-ray absorption near-edge structure (XANES) spectroscopy revealed that {gamma}-sterilized sediments were actually better sorbents of U(VI), despite the absence of any measurable biological activity. These results indicate that {gamma}-irradiation induced significant physico-chemical changes in the sediment which is contrary to numerous other studies identifying {gamma}-sterilization as an effective and minimally invasive technique. To identify the extent and method of alteration of the soil as a result of {gamma}-sterilization, untreated soil samples, physically separated size fractions, and chemically extracted fractionsmore » of the soil were analyzed pre- and post-sterilization. The effects of sterilization on mineralogy, pH, natural organic matter (NOM), cation exchange capacity (CEC), and iron oxidation state were determined. Results indicated that major mineralogy of the clay and whole sediment samples was unchanged. Sediment pH decreased only slightly with {gamma}-irradiation; however, irradiation produced a significant decrease in CEC of the untreated sediments and affected both the organic and inorganic fractions. Moessbauer spectra of non-sterile and {gamma}-sterilized sediments measured more reduced iron present in {gamma}-sterilized sediments compared to non-sterile samples. Our results suggest that sterilization by {gamma}-irradiation induced iron reduction that may have increased the sorption and/or reduction of U(VI) onto these sediments. However, Moessbauer and batch sorption data are somewhat contradictory, the former indicates that the iron oxide or iron hydroxide minerals are more significantly reduced while the later indicates that reduced clay minerals account for greater sorption of U(VI).« less

  12. Hysteroscopic tubal sterilization: a health economic literature review.

    PubMed

    2013-01-01

    Hysteroscopic sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. In contrast to the laparoscopic technique, a hysteroscope is used to pass permanent microinserts through the cervix and place them in the fallopian tubes. This procedure does not require local or general anesthesia and can be performed in an office setting. The objective of this analysis was to determine, based on published literature, the cost-effectiveness of hysteroscopic tubal sterilization (HS) compared with laparoscopic tubal ligation (LS) for permanent female sterilization. A systematic literature search was conducted for studies published between January 1, 2008, and December 11, 2012. Potentially relevant studies were identified based on the title and abstract. Cost-utility analyses (studies that report outcomes in terms of costs and quality-adjusted life-years) were prioritized for inclusion. When not available, cost-effectiveness, cost-benefit, and cost-consequence analyses were considered. Costing studies were considered in the absence of all other analyses. A total of 33 abstracts were identified. Three cost analyses were included. A retrospective chart review from Canada found that HS was $111 less costly than LS; a prospective activity-based cost management study from Italy reported that it was €337 less costly than LS; and the results of an American decision model showed that HS was $1,178 less costly than LS. All studies had limited applicability to the Ontario health care system due to differences in setting, resource use, and costs. Three cost analyses found that, although the HS procedure was more expensive due to the cost of the microinserts, HS was less costly than LS overall due to the shorter recovery time required. Hysteroscopic sterilization is a minimally invasive alternative to conventional tubal ligation for women who want a permanent method of contraception. Both approaches involve closing off the fallopian tubes, preventing the egg from moving down the tube and the sperm from reaching the egg. Tubal ligation is a surgical procedure to tie or seal the fallopian tubes, and it usually requires general anesthesia. In contrast, hysteroscopic tubal sterilization can be performed in 10 minutes in an office setting without general or even local anesthesia. A tiny device called a microinsert is inserted into each fallopian tube through the vagina, cervix, and uterus without surgery. An instrument called a hysteroscope allows the doctor to see inside the body for the procedure. Once the microinserts are in place, scar tissue forms around them and blocks the fallopian tubes. Health Quality Ontario commissioned a systematic review of published economic literature to determine whether hysteroscopic sterilization is cost-effective compared to tubal ligation. This review did not find any studies that reported results in terms of both costs and effectiveness or costs and quality-adjusted life-years. We did find 3 costing studies and included them in our review. All of these studies found that when hysteroscopic sterilization was performed as an outpatient procedure, it was less expensive than tubal ligation due to a shorter recovery time. However, none of the studies apply directly to Ontario because of differences in our health care system compared to those in the studies.

  13. Apparatus and method for preparing oxygen-15 labeled water H.sub.2 [.sup.15 O] in an injectable form for use in positron emission tomography

    DOEpatents

    Ferrieri, Richard A.; Schlyer, David J.; Alexoff, David

    1996-01-09

    A handling and processing apparatus for preparing Oxygen-15 labeled water (H.sub.2 [.sup.15 O]) in injectable form for use in Positron Emission Tomography from preferably H.sub.2 [.sup.15 O] produced by irradiating a flowing gas target of nitrogen and hydrogen. The apparatus includes a collector for receiving and directing a gas containing H.sub.2 [.sup.15 O] gas and impurities, mainly ammonia (NH.sub.3) gas into sterile water to trap the H.sub.2 [.sup.15 O] and form ammonium (NH.sub.4.sup.+) in the sterile water. A device for displacing the sterile water containing H.sub.2 [.sup.15 O] and NH.sub.4.sup.+ through a cation resin removes NH.sub.4.sup.+ from the sterile water. A device for combining the sterile water containing H.sub.2 [.sup.15 O] with a saline solution produces an injectable solution. Preferably, the apparatus includes a device for delivering the solution to a syringe for injection into a patient. Also, disclosed is a method for preparing H.sub.2 [.sup.15 O] in injectable form for use in Positron Emission Tomography in which the method neither requires isotopic exchange reaction nor application of high temperature.

  14. Biocompatibility differences with respect to the dialyzer sterilization method.

    PubMed

    Müller, T F; Seitz, M; Eckle, I; Lange, H; Kolb, G

    1998-01-01

    The impact of the method of sterilization (steam vs. ethylene oxide, ETO) on indices of biocompatibility is investigated using polysulfone membranes. Eight patients were treated with a random choice of the high-flux membranes F60S (steam) and F60 (ETO) and the low-flux membrane F6 (ETO). Blood samples were taken prior to and 5, 15, 30, 60, and 180 min after the start of hemodialysis. White blood cell count, platelet count, and plasma concentrations of polymorphonuclear neutrophil elastase, complements C3a and C5a, and beta2-microglobulin were determined. The dialysis procedure was associated with a significant decrease in white blood cell count and beta2-microglobulin level and a significant increase in polymorphonuclear neutrophil elastase and complement C3a and C5a levels. However, the steam-sterilized F60S membrane had a significantly lower impact on the biocompatibility indices than the ETO-sterilized F60 and F6 membranes (p < 0.05 or p < 0.001 for the individual markers). We conclude that using steam instead of ETO for sterilization may improve the biocompatibility of membranes.

  15. The influence of sterilization processes on the micromechanical properties of carbon fiber-reinforced PEEK composites for bone implant applications.

    PubMed

    Godara, A; Raabe, D; Green, S

    2007-03-01

    The effect of sterilization on the structural integrity of the thermoplastic matrix composite polyetheretherketone (PEEK) reinforced with carbon fibers (CF) is investigated by nanoindentation and nanoscratch tests. The use of the material as a medical implant grade requires a detailed understanding of the micromechanical properties which primarily define its in vivo behavior. Sterilization is a mandatory process for such materials used in medical applications like bone implants. The steam and gamma radiation sterilization processes employed in this study are at sufficient levels to affect the micromechanical properties of some polymer materials, particularly in the interphase region between the polymer matrix and the reinforcing fibers. Nanoindentation and nanoscratch tests are used in this work to reveal local gradients in the hardness and the elastic properties of the interphase regions. Both methods help to explore microscopic changes in the hardness, reduced stiffness and scratch resistance in the interphase region and in the bulk polymer matrix due to the different sterilization processes employed. The results reveal that neither steam nor gamma radiation sterilization entails significant changes of the reduced elastic modulus, hardness or coefficient of friction in the bulk polymer matrix. However, minor material changes of the PEEK matrix were observed in the interphase region. Of the two sterilization methods used, the steam treatment has a more significant influence on these small changes in this region and appears to increase slightly the thickness of the interphase zone.

  16. Evaluation of growth based rapid microbiological methods for sterility testing of vaccines and other biological products.

    PubMed

    Parveen, Seema; Kaur, Simleen; David, Selwyn A Wilson; Kenney, James L; McCormick, William M; Gupta, Rajesh K

    2011-10-19

    Most biological products, including vaccines, administered by the parenteral route are required to be tested for sterility at the final container and also at various stages during manufacture. The sterility testing method described in the Code of Federal Regulations (21 CFR 610.12) and the United States Pharmacopoeia (USP, Chapter <71>) is based on the observation of turbidity in liquid culture media due to growth of potential contaminants. We evaluated rapid microbiological methods (RMM) based on detection of growth 1) by adenosine triphosphate (ATP) bioluminescence technology (Rapid Milliflex(®) Detection System [RMDS]), and 2) by CO(2) monitoring technologies (BacT/Alert and the BACTEC systems), as alternate sterility methods. Microorganisms representing Gram negative, Gram positive, aerobic, anaerobic, spore forming, slow growing bacteria, yeast, and fungi were prepared in aliquots of Fluid A or a biological matrix (including inactivated influenza vaccines) to contain approximately 0.1, 1, 10 and 100 colony forming units (CFU) in an inoculum of 10 ml. These preparations were inoculated to the specific media required for the various methods: 1) fluid thioglycollate medium (FTM) and tryptic soy broth (TSB) of the compendial sterility method (both membrane filtration and direct inoculation); 2) tryptic soy agar (TSA), Sabouraud dextrose agar (SDA) and Schaedler blood agar (SBA) of the RMDS; 3) iAST and iNST media of the BacT/Alert system and 4) Standard 10 Aerobic/F and Standard Anaerobic/F media of the BACTEC system. RMDS was significantly more sensitive in detecting various microorganisms at 0.1CFU than the compendial methods (p<0.05), whereas the compendial membrane filtration method was significantly more sensitive than the BACTEC and BacT/Alert methods (p<0.05). RMDS detected all microorganisms significantly faster than the compendial method (p<0.05). BacT/Alert and BACTEC methods detected most microorganisms significantly faster than the compendial method (p<0.05), but took almost the same time to detect the slow growing microorganism P. acnes, compared to the compendial method. RMDS using SBA detected all test microorganisms in the presence of a matrix containing preservative 0.01% thimerosal, whereas the BacT/Alert and BACTEC systems did not consistently detect all the test microorganisms in the presence of 0.01% thimerosal. RMDS was compatible with inactivated influenza vaccines and aluminum phosphate or aluminum hydroxide adjuvants at up to 8 mg/ml without any interference in bioluminescence. RMDS was shown to be acceptable as an alternate sterility method taking 5 days as compared to the 14 days required of the compendial method. Isolation of microorganisms from the RMDS was accomplished by re-incubation of membranes with fresh SBA medium and microbial identification was confirmed using the MicroSEQ Identification System. BacT/Alert and BACTEC systems may be applicable as alternate methods to the compendial direct inoculation sterility method for products that do not contain preservatives or anti-microbial agents. Published by Elsevier Ltd.

  17. Evaluation of tensile strength and surface topography of orthodontic wires after infection control procedures: An in vitro study

    PubMed Central

    Brindha, M.; Kumaran, N. Kurunji; Rajasigamani, K.

    2014-01-01

    Aim: The aim of this study is to evaluate, the influence of four types of sterilization/disinfection procedures (autoclave, hot air oven, glutaraldehyde, and ultraviolet [UV] light) on the tensile strength and surface topography of three orthodontic wires (stainless steel (SS), titanium - molybdenum alloy [TMA], and cobalt chromium (CoCr)). Materials and Methods: Sample comprised of three types of 8 inches straight length segments of orthodontic wires. They were divided into three groups according to wire composition comprising of 50 samples each. Totally 50 samples of each group were then equally divided into five subgroups according to sterilization method. After sterilization and disinfection of the experimental group, surface topography was examined with scanning electron microscope (SEM) and tensile strength was tested using universal testing machine. Result: The results of this study show that the mean ultimate tensile strength (UTS) of SS wire after four sterilization procedures were similar to the control group (1845.815 ± 142.29 MPa). The mean UTS of TMA wire increases after four sterilization procedures when compared with the control group (874.107 ± 275.939 MPa). The mean UTS of CoCr wire remains same after UV light disinfection, but increases after other three sterilization procedures when compared with the control group (1449.759 ± 156.586 MPa). SEM photographs of the present study shows gross increase in pitting roughness of the surface topography of all the three types of wires after four types of sterilization. Conclusion: Orthodontists who want to offer maximum safety for their patients can sterilize orthodontic wires before placement, as it does not deteriorate the tensile strength and surface roughness of the alloys. PMID:25210383

  18. Baby bottle steam sterilizers disinfect home nebulizers inoculated with bacterial respiratory pathogens.

    PubMed

    Towle, Dana; Callan, Deborah A; Farrel, Patricia A; Egan, Marie E; Murray, Thomas S

    2013-09-01

    Contaminated nebulizers are a potential source of bacterial infection but no single method is universally accepted for disinfection. We hypothesized that baby-bottle steam sterilizers effectively disinfect home nebulizers. Home nebulizers were inoculated with the common CF respiratory pathogens methicillin resistant Staphylococcus aureus, Burkholderia cepacia, Haemophilus influenzae, mucoid and non mucoid Pseudomonas aeruginosa, and Stenotrophomonas maltophilia. The nebulizers were swabbed for bacterial growth, treated with either the AVENT (Philips), the NUK Quick & Ready (Gerber) or DRY-POD (Camera Baby) baby bottle steam sterilizer and reswabbed for bacterial growth. All steam sterilizers were effective at disinfecting all home nebulizers. Viable bacteria were not recovered from any inoculated site after steam treatment, under any conditions tested. Steam treatment is an effective disinfection method. Additional studies are needed to confirm whether these results are applicable to the clinical setting. Copyright © 2012 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  19. Material conformity and bactericidal properties of high-frequency-pulse-modulated and low-frequency-pulse-excited plasmas

    NASA Astrophysics Data System (ADS)

    Okawa, H.; Akitsu, T.

    2018-05-01

    Plasma sterilization attracts an increasing attention as an alternative method for chemical sterilization. In this study, we investigate plasma sterilization for practical applications, particularly in dentistry and oral surgery [1]. Helium-diluted oxygen was excited by a dielectric barrier electrode at normal atmospheric pressure. Control of the neutral gas temperature was performed under the plasma sterilization. The relation between the intensity of the spectral emission from the excited oxygen atoms and bactericidal effect was investigated using Bacillus stearothermophilus and opportunistic infection bacterium. A comparison is performed with a low-frequency wide-gap discharge. Degradation and material conformity were investigated using the Tyvek unwoven fabric for the sterile package and soft-silicone resin, methyl-methacrylate powder filler used in the dental surgery.

  20. Qualification of a rapid readout biological indicator with moist heat sterilization.

    PubMed

    McCormick, Patrick; Finocchario, Catherine; Manchester, Robert; Glasgow, Louis; Costanzo, Stephen

    2003-01-01

    Biological indicators are recognized as an important component in the validation and routine monitoring of moist heat (steam) sterilization processes. Due to the need to allow for the recovery and outgrowth of test organisms that may have been sub-lethally injured, between 2-5 days of incubation are typically required before the outcome of sterilization processing can be reliably interpreted. Rapid readout biological indicators that incorporate the response of a heat resistant enzyme provide a means for assessing the efficacy of moist heat sterilization within hours of processing. This study describes the qualification of the 3M Attest 1292 Rapid Readout Biological Indicator with moist heat sterilization according to the procedures described in the PDA Technical Report No. 33, "Evaluation, Validation and Implementation of New Microbiological Testing Methods".

  1. Food irradiation development in Pakistan

    NASA Astrophysics Data System (ADS)

    Khan, I.

    The large scale trials were held to extend the storage life of potatoes, onions and dry fruits by gamma radiation. It was concluded that radiation preservation of potatoes and onions was much cheaper as compared to conventional methods. A dose of 1 kGy can control the insects in dry fruits and nuts. The consumers' acceptability and market testing performed during the last four years are also conducive to the commercialization of the technology in this country. The Government of Pakistan has accorded clearance for the irradiation of some food items like potatoes, onions, garlic and spices for human consumption. The Pakistan Radiation Services (PARAS), the commercial irradiator (200 Kci) at Lahore, has already started functioning in April, 1987. It is planned to start large scale sterilization of spices by gamma radiation in PARAS shortly.

  2. Family planning and maternal and child health services.

    PubMed

    Singh, A

    1975-12-01

    Considerable effort has been made in the area of family planning in the State of Punjab. Family planning personnel has been recruited and trained at the State Family Planning Training and Research Center in Kharar; supplies of Nirodh, IUDs, oral contraceptives, and hospital equipment along with transportation facilities have been made available; and there has been some building construction. The State Health Education Bureau has worked to produce publicity material and has also used the mass media to create awareness of family planning among the people. As many as 120 rural and 49 urban Family Welfare Planning Centers are providing family planning services along with 856 subcenters in rural areas. 1123 other institutions are also doing family planning work in addition to the efforts of 34 mobile sterilization and IUD units attached to the District Family Planning Bureau and the contributions of some voluntary organizations. Although the state has adopted the cafeteria approach to family planning and the focus is on provision of family planning services on routine days in the various institutions to well-motivated couples, mass family planning camps for vasectomy, tubal ligations, and IUD insertions have been held with considerable success. Additionally, the State has integrated family planning programs with maternal and child health care in order to provide a totality of service. This precedes the total integration of this national program w ith general health services. Punjab has done well in achieving its targets for 1974-1975. Sterilization targets were set at 38,300 and 36,460 sterilizations, 95.2% of the target, were performed. IUD targets were 27,000, and the number achieved was 39,637 or 109.4%. The conventional contraceptive user target was 99,800, and 151,976 or 152.3% of the target figure became conventional contraceptive users.

  3. Field evaluations of the VD max approach for substantiation of a 25 kGy sterilization dose and its application to other preselected doses

    NASA Astrophysics Data System (ADS)

    Kowalski, John B.; Herring, Craig; Baryschpolec, Lisa; Reger, John; Patel, Jay; Feeney, Mary; Tallentire, Alan

    2002-08-01

    The International and European standards for radiation sterilization require evidence of the effectiveness of a minimum sterilization dose of 25 kGy but do not provide detailed guidance on how this evidence can be generated. An approach, designated VD max, has recently been described and computer evaluated to provide safe and unambiguous substantiation of a 25 kGy sterilization dose. The approach has been further developed into a practical method, which has been subjected to field evaluations at three manufacturing facilities which produce different types of medical devices. The three facilities each used a different overall evaluation strategy: Facility A used VD max for quarterly dose audits; Facility B compared VD max and Method 1 in side-by-side parallel experiments; and Facility C, a new facility at start-up, used VD max for initial substantiation of 25 kGy and subsequent quarterly dose audits. A common element at all three facilities was the use of 10 product units for irradiation in the verification dose experiment. The field evaluations of the VD max method were successful at all three facilities; they included many different types of medical devices/product families with a wide range of average bioburden and sample item portion values used in the verification dose experiments. Overall, around 500 verification dose experiments were performed and no failures were observed. In the side-by-side parallel experiments, the outcomes of the VD max experiments were consistent with the outcomes observed with Method 1. The VD max approach has been extended to sterilization doses >25 and <25 kGy; verification doses have been derived for sterilization doses of 15, 20, 30, and 35 kGy. Widespread application of the VD max method for doses other than 25 kGy must await controlled field evaluations and the development of appropriate specifications/standards.

  4. Analysis of pain and satisfaction with office-based hysteroscopic sterilization.

    PubMed

    Levie, Mark; Weiss, Gil; Kaiser, Bente; Daif, Jennifer; Chudnoff, Scott G

    2010-09-01

    To assess pain and patient satisfaction with office-based hysteroscopic sterilization. This prospective, observational study was designed to assess patient pain perception and satisfaction with office-based hysteroscopic sterilization using the Essure device (Conceptus, Mountain View, CA). Faculty practice office at an inner-city urban medical center. Women seeking hysteroscopic sterilization. Office hysteroscopic sterilization under local anesthesia. Pain assessed at the time of the procedure by a 0-10 visual scale and satisfaction by a 1-5 scale. From June 2003 to June 2006, 209 patients were recruited. The mean scores for average procedural pain, most procedural pain, and average menstrual pain were 2.6+/-2.1, 3.3+/-2.5, and 3.6+/-2.6, respectively. Standardized pain scores revealed that 149 subjects (70%) experienced average pain that was less than or equal to the pain experienced with their menses. Mean satisfaction rating for the procedure was 4.7+/-0.71. Office-based hysteroscopic sterilization performed with local anesthesia alone is well tolerated, and patients are satisfied with this method for permanent sterilization. Copyright (c) 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  5. Surgical sterilization: an underutilized procedure for evaluating the merits of induced sterility

    USGS Publications Warehouse

    Kennelly, James J.; Converse, Kathryn A.

    1993-01-01

    Despite more than 4 decades of effort, development of effective wildlife damage control programs based on sterilization of target species has met with limited success. This is partly due to the fact that investigators have assumed, rather than empirically tested, whether the reproductive strategies of the target populations were vulnerable to the planned treatment. Equally important, methods selected to include sterility usually involve a chemical agent that can affect sociosexual behaviors of the nuisance population. In this report, we illustrate how surgically induced sterility circumvents both problems--how the concept without the potentially confounding secondary effects of a chemical. We assessed the merits of initiating research to develop a male chemosterilant for Norway rats, red-winged blackbirds, beaver, and Canada geese by inducing sterility surgically. The infidelity of many red-winged females to their polygynous territorial male was surprising and argued against searching for a male sterilant. On the other hand, beaver and Canada goose studies confirmed previous reports that both form par-bonds and are monogamous. Both should be vulnerable to a male chemosterilant approach, and research toward this goal is justified.

  6. Male perceptions on female sterilization: a community-based study in rural Central India.

    PubMed

    Char, Arundhati; Saavala, Minna; Kulmala, Teija

    2009-09-01

    Use of modern contraceptive methods has increased fourfold in India since the 1970s, characterized by a predominance of female sterilization. There has been considerable investigation about women's choice of female sterilization, but little from the male perspective. Seven focus group discussions were conducted among 58 men currently married to women aged 15-45, followed by a cross-sectional survey among 793 men currently married to same-aged women. Bivariate analysis was used for the survey data, and content analysis was used for the qualitative data. Men's primary source of reproductive health information was mass media, although they expressed interest in getting information through discussion with knowledgeable sources. Men understood family planning and contraception to be two separate issues: Men viewed "family planning" as synonymous with female sterilization, whereas they saw "contraception" as referring to spacing methods, knowledge of which was limited. Thirty-four percent of men reported that their wives had been sterilized; 79% of men who did not rely on any permanent method said they wanted their wives to be sterilized. In focus group discussions, most men reported themselves as their family's sole decision maker about reproductive health; however, only one-third of survey respondents did so. Men are interested in acquiring family planning information, but lack knowledge about available information sources, which hampers their ability to make informed family planning choices. Family planning service providers and program planners need to be aware of males' knowledge and perceptions pertaining to family planning, and make appropriate modifications to communication strategies.

  7. Experiences of coercion to sterilize and forced sterilization among women living with HIV in Latin America.

    PubMed

    Kendall, Tamil; Albert, Claire

    2015-01-01

    Forced and coerced sterilization is an internationally recognized human rights violation reported by women living with HIV (WLHIV) around the globe. Forced sterilization occurs when a person is sterilized without her knowledge or informed consent. Coerced sterilization occurs when misinformation, intimidation tactics, financial incentives or access to health services or employment are used to compel individuals to accept the procedure. Drawing on community-based research with 285 WLHIV from four Latin American countries (El Salvador, Honduras, Mexico and Nicaragua), we conduct thematic qualitative analysis of reports of how and when healthcare providers pressured women to sterilize and multivariate logistic regression to assess whether social and economic characteristics and fertility history were associated with pressure to sterilize. A quarter (23%) of the participant WLHIV experienced pressure to sterilize post-diagnosis. WLHIV who had a pregnancy during which they (and their healthcare providers) knew their HIV diagnosis were almost six times more likely to experience coercive or forced sterilization than WLHIV who did not have a pregnancy with a known diagnosis (OR 5.66 CI 95% 2.35-13.58 p≤0.001). WLHIV reported that healthcare providers told them that living with HIV annulled their right to choose the number and spacing of their children and their contraceptive method, employed misinformation about the consequences of a subsequent pregnancy for women's and children's health, and denied medical services needed to prevent vertical (mother-to-child) HIV transmission to coerce women into accepting sterilization. Forced sterilization was practiced during caesarean delivery. The experiences of WLHIV indicate that HIV-related stigma and discrimination by healthcare providers is a primary driver of coercive and forced sterilization. WLHIV are particularly vulnerable when seeking maternal health services. Health worker training on HIV and reproductive rights, improving counselling on HIV and sexual and reproductive health for WLHIV, providing State mechanisms to investigate and sanction coercive and forced sterilization, and strengthening civil society to increase WLHIV's capacity to resist coercion to sterilize can contribute to preventing coercive and forced sterilization. Improved access to judicial and non-judicial mechanisms to procure justice for women who have experienced reproductive rights violations is also needed.

  8. Preliminary evaluation of several disinfection/sterilization techniques for use with microdialysis probes.

    PubMed

    Huff, Jacquelyn K; Bresnahan, James F; Davies, Malonne I

    2003-06-06

    This study evaluated the suitability of some disinfection and sterilization methods for use with microdialysis probes. Disinfection or sterilization should minimize the tissue inflammatory reaction and improve the long-term health of rats on study and ensure the quality of data obtained by microdialysis sampling. Furthermore, the treatment should not negatively impact probe integrity or sampling performance. The techniques chosen for evaluation included two disinfection methods (70% ethanol and a commercial contact lens solution) and two sterilization methods (hydrogen peroxide plasma, and e-beam radiation). Linear microdialysis probes treated by these processes were compared to untreated probes removed from the manufacturer's packaging as if sterile (the control group). The probes were aseptically implanted in the livers of rats and monitored for 72 hours. The parameters chosen to evaluate probe performance were relative sample mass recovery and the relative in vivo extraction efficiency of the probe for caffeine. Post mortem bacterial counts and histopathology examination of liver tissue were also conducted. The probes remained intact and functional for the entire study period. The methods tested did not acutely alter the probes although hydrogen peroxide plasma and contact lens solution groups showed reduced extraction efficiencies. Minimal tissue damage was observed surrounding the probes and acute inflammatory reaction was mild to moderate. Low numbers of bacterial colonies from the implantation sites indicates that the health of animals in this study was not impaired. This was also true for the control group (untreated probe).

  9. Nitrogen Dioxide Sterilization in Low-Resource Environments: A Feasibility Study

    PubMed Central

    Avasthi, Trisha; Trilling, Ariel

    2015-01-01

    Access to sterilization is a critical need for global healthcare, as it is one of the prerequisites for safe surgical care. Lack of sterilization capability has driven up healthcare infection rates as well as limited access to healthcare, especially in low-resource environments. Sterilization technology has for the most part been static and none of the established sterilization methods has been so far successfully adapted for use in low-resource environments on a large scale. It is evident that healthcare facilities in low-resource settings require reliable, deployable, durable, affordable, easily operable sterilization equipment that can operate independently of scarce resources. Recently commercialized nitrogen dioxide (NO2) sterilization technology was analyzed and adapted into a form factor suitable for use in low-resource environments. Lab testing was conducted in microbiological testing facilities simulating low-resource environments and in accordance with the requirements of the international sterilization standard ANSI/AAMI/ISO 14937 to assess effectiveness of the device and process. The feasibility of a portable sterilizer based on nitrogen dioxide has been demonstrated, showing that sterilization of medical instruments can occur in a form factor suitable for use in low-resource environments. If developed and deployed, NO2 sterilization technology will have the twin benefits of reducing healthcare acquired infections and limiting a major constraint for access to surgical care on a global scale. Additional benefits are achieved in reducing costs and biohazard waste generated by current health care initiatives that rely primarily on disposable kits, increasing the effectiveness and outreach of these initiatives. PMID:26098905

  10. Preparation of sterile xenon-133 in saline for tissue perfusion studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DiPiazza, H.J.; Harbert, J.C.

    1983-11-01

    A simple, inexpensive method of obtaining Xe-133 in sterile saline is presented. The method uses commercial xenon ampules supplied for pulmonary ventilation studies. As much as 10% of the gas activity can be recovered per aliquot by cooling the saline to 4/sup 0/C. The specific activities obtained are adequate for most tissue perfusion studies.

  11. Cartographie de corps stériles sous couverture quaternaire par méthode de résistivités électriques dans le gisement phosphaté de Sidi Chennane (Maroc)Sterile bodies mapping under Quaternary cover using resistivity-sounding method in the phosphatic bearing of Sidi Chennane (Morocco)

    NASA Astrophysics Data System (ADS)

    Kchikach, Azzouz; Jaffal, Mohammed; Aı̈fa, Tahar; Bahi, Lahcen

    In the Ouled Abdoun sedimentary basin (Morocco), the phosphatic series is composed of regular interbedded phosphatic and marly limestone layers. Some phosphatic deposits in this basin show sterile bodies causing two kinds of problems: (1) as they are hard, compact and masked by a Quaternary cover, they disturb the exploitation in some yards and give bad reserve calculations; (2) even the use of wells and mechanical boreholes did not evidence their delimitation. Therefore, electric prospecting method has been used to evidence their geometrical shape. Petrographical and geometrical studies on these sterile bodies allowed us to choose the appropriate geophysical method to map them. The electrical resistivity survey that we used in the Sidi Chennane area shows that this technique is a good tool to contour these sterile bodies. This method is now considered as useful to the mining engineers to get round them during the exploitation. To cite this article: A. Kchikach et al., C. R. Geoscience 334 (2002) 379-386.

  12. In vivo degradation of polyethylene liners after gamma sterilization in air.

    PubMed

    Kurtz, Steven M; Rimnac, Clare M; Hozack, William J; Turner, Joseph; Marcolongo, Michele; Goldberg, Victor M; Kraay, Matthew J; Edidin, Avram A

    2005-04-01

    Ultra-high molecular weight polyethylene degrades during storage in air following gamma sterilization, but the extent of in vivo degradation remains unclear. The purpose of this study was to quantify the extent to which the mechanical properties and oxidation of conventional polyethylene acetabular liners treated with gamma sterilization in air change in vivo. Fourteen modular cementless acetabular liners were revised at an average of 10.3 years (range, 5.9 to 13.5 years) after implantation. All liners, which had been machined from GUR 415 resin, had been gamma-sterilized in air; the average shelf life was 0.3 year (range, 0.0 to 0.8 year). After removal, the components were expeditiously frozen to minimize ex vivo changes to the polyethylene prior to characterization. The average duration between freezing and testing was 0.6 year. Mechanical properties and oxidation were measured with use of the small-punch test and Fourier transform infrared spectroscopy, respectively, in the loaded and unloaded regions of the liners. There was substantial regional variation in the mechanical properties and oxidation of the retrieved liners. The ultimate load was observed to vary by >90% near the surface. On the average, the rim and the unloaded bearing showed evidence of severe oxidation near the surface after long-term in vivo aging, but these trends were not typically observed on the loaded bearing surface or near the backside of the liners. The mechanical properties of polyethylene that has been gamma-sterilized in air may decrease substantially in vivo, depending on the location in the liner. The most severe oxidation was observed at the rim, suggesting that the femoral head inhibits access of oxygen-containing body fluids to the bearing surface. This is perhaps why in vivo oxidation has not been associated with clinical performance to date.

  13. Sterilization of root canal spaces using an Nd:YAG laser, in vitro

    NASA Astrophysics Data System (ADS)

    Goodis, Harold E.; White, Joel M.; Yee, Barbara; Marshall, Sally J.; Marshall, Grayson W.

    1995-05-01

    A smear layer is created during the cleaning and shaping of root canal systems. The Nd:YAG laser has been shown to be effective in removing that smear layer and any tissue remnants from prepared root canal systems suggesting that it may aid in root canal sterilization without detrimental thermal effects to adjacent tissues. The root canal system of 72 single-rooted teeth was conventionally prepared and sterilized using gamma radiation. The teeth were divided into three groups of 24 each, 8 of which were inoculated only with sterile broth and remained as negative controls. Sixteen teeth of each group were inoculated with one of three organisms of 106 to 1010 CFU/(mu) l: B subtilis (BS), E. coli (EC) and S. marcescens (SM) (10 (mu) l). Eight in each group were not treated further and served as positive controls. Sixteen test teeth were treated with the laser three times using each exposure parameter: 1 W, 10 Hz pulses per second (pps); 2 W, 20 Hz; and 3 W, 30 Hz inserted to the radiographic apex. Laser exposures were completed while withdrawing the fiber from the root canal system. At completion of laser exposure, all teeth were cultured, using sterile paper points and plated on brain heat infusion agar. Three cultures were taken for each tooth, the plates incubated for 72 hours, and read for the presence of growth of colony-forming units. The laser was able to reduce the number of organisms placed in root canal systems, and suggests that the laser may be used in root canal therapy for bacterial reduction and cleaning of the root canal space.

  14. Can oil lubricated dental handpieces be sterilized?: part 1. The problem.

    PubMed

    Kudhail, Ravinder

    2013-09-01

    HTM 01-05 guidelines state that decontamination of handpieces remains a challenge, in particular the lumen, due to oil impeding access for steam sterilization. This paper discusses important aspects of cleaning and sterilization of the handpiece lumen and critically appraises the literature found on this topic. The paper is not intended to cover precleaning methods in detail. The complex structure of handpiece lumens makes them difficult to sterilize. Current knowledge of this subject is necessary for general dental practitioners to decide on investment in new equipment correctly, which has been validated by the manufacturer, in order to comply with HTM 01-05 guidelines.

  15. Sterile Neutrino Search with the Double Chooz Experiment

    NASA Astrophysics Data System (ADS)

    Hellwig, D.; Matsubara, T.; Double Chooz Collaboration

    2017-09-01

    Double Chooz is a reactor antineutrino disappearance experiment located in Chooz, France. A far detector at a distance of about 1 km from reactor cores is operating since 2011; a near detector of identical design at a distance of about 400 m is operating since begin 2015. Beyond the precise measurement of θ 13, Double Chooz has a strong sensitivity to so called light sterile neutrinos. Sterile neutrinos are neutrino mass states not taking part in weak interactions, but may mix with known neutrino states. In this paper, we present an analysis method to search for sterile neutrinos and the expected sensitivity with the baselines of our detectors.

  16. Component Selection for Sterile Compounding.

    PubMed

    Dilzer, Richard H

    2017-01-01

    This article describes the factors to consider, as well as the process of proper component selection, for use in preparing compounded sterile preparations. Special emphasis is placed on individual chemical factors that may impact a preparation's accuracy and potency. Values reported in a typical certificate of analysis are discussed, including methods of identifying any required adjustments to a master formulation or compounding record during the compounding of sterile preparations. Proper screening of the certificate of analysis, the Safety Data Sheet, procedural documentation, and the filing of all certificates of conformance are crucial to the operation of a sterile compounding facility. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  17. Low-temperature sterilization of wrapped materials using flexible sheet-type dielectric barrier discharge

    NASA Astrophysics Data System (ADS)

    Eto, Hiroyuki; Ono, Yoshihito; Ogino, Akihisa; Nagatsu, Masaaki

    2008-12-01

    A flexible sheet-type dielectric barrier discharge (DBD) was studied for the low-temperature sterilization of medical instruments wrapped with Tyvek packaging. Sterilization experiments using Geobacillus stearothermophilus spores with a population of 106 were carried out with various mixtures of nitrogen and oxygen. We confirmed the inactivation of spores after 4.5 min of DBD irradiation at a temperature of 28.4 °C and relative humidity of 64.4%. The main sterilizing factors of this method are the ozone and UV emissions generated by DBD in dry air and synergistic OH radicals generated by DBD in moist air.

  18. [Legal statutes on sterilization].

    PubMed

    Zupancic, K

    1980-01-01

    Sterilization in Yugoslavia is no population policy measure. Decision about the birth of children is free, a private problem of any individual, a basic right guaranteed by the Constitution. However, according to certain laws in Slovenia and Croatia, sterilization is allowed as a family planning method in persons over 35 year old. Only exceptionally can sterilization be applied in persons younger than 35 years: according to the Slovenian law, in cases when a person lacks the capacity of reasoning and also when there are medical indications, and according to the Croatian law, when there are medical and eugenic reasons (if the child is supposed to be born with negative congenital properties).

  19. Cryoradiation sterilization—Contemporary state and outlook

    NASA Astrophysics Data System (ADS)

    Talrose, V. L.; Trofimov, V. I.

    1995-02-01

    The new approach of radiation sterilization — cryoradiosterilization with programmed freezing — was developed for pharmaceutical solutions. Both scientific and technical problems are solved, the results are discussed. Programmed freezing of vials with the drug's solutions provides the high stability of soluted components with biological activity at sterilizing irradiation without significant change of sterilization doses. Physical, chemical, biological and pharmacological properties of a lot of drug solutions for injection satisfy official requirements after cryoradiation sterilization treatment. This method seems to be especially important for the protein systems which could be infected by dangerous viruses (VIH, hepatitis B): blood plasma, diagnostic sera, protein preparations manufactured from donor's blood, etc.

  20. Risks and Benefits of Salpingectomy at the Time of Sterilization.

    PubMed

    Castellano, Tara; Zerden, Matthew; Marsh, Laura; Boggess, Kim

    2017-11-01

    Bilateral salpingectomy reduces the risk ovarian cancer. The Society of Gynecologic Oncology has recommended surgeons discuss salpingectomy with patients desiring sterilization. This review summarizes current literature on the benefits and risks of bilateral salpingectomy to reduce ovarian cancer risk. Areas of insufficient evidence and directions for further research are discussed. We examined the benefits and risks of bilateral salpingectomy for female surgical sterilization, using a PubMed and EMBASE literature review. Search parameters included articles in English language and keywords "salpingectomy" or "ovarian cancer" combined with "contraception," "sterilization," or "tubal ligation." We reviewed 4 high-quality studies that investigated the increased risk reduction of bilateral salpingectomy compared with traditional sterilization. Overall, evidence shows that salpingectomy moderately decreases the risk of ovarian cancer compared with traditional sterilization. An additional 4 studies, including a meta-analysis, showed salpingectomy likely does not have significant long-term impact on ovarian reserve. Additional benefits include improved contraceptive efficacy and elimination of subsequent ectopic pregnancies. Risks include need for in vitro fertilization for patients experiencing sterilization regret, increases in operative time, and potential increases in surgical risks. Bilateral salpingectomy can reduce ovarian cancer risk compared with traditional sterilization; however, research regarding other outcomes is limited. Challenges to implementation include physician concern regarding surgical risks and patient education. Studies investigating patient-based outcomes are lacking. Bilateral salpingectomy for surgical sterilization is a reasonable option when patients are appropriately informed. Ovarian cancer risk reduction should be one of several factors considered when patients choose a surgical sterilization method.

  1. [Influence of sterilization treatments on continuous carbon-fiber reinforced polyolefin composite].

    PubMed

    Guan, Shi-bing; Hou, Chun-lin; Chen, Ai-min; Zhang, Wei; Wang, Ji-e

    2007-08-21

    To evaluate the influence of sterilization treatment on continuous carbon-fiber reinforced polyolefin composite (CFRP) so as to provide experimental reference for selection of sterilization method for CFRP. Seventy bars of CFRP were divided into 7 equal groups to undergo sterilization by autoclave, 2% glutaraldehyde soaking, 75% alcohol soaking, ethylene oxide sterilization, and Co-60 gamma ray irradiation of the dosages 11 kGy, 25 kGy, and 18 kGy respectively, and another 10 bars were used as blank controls. Then the bars underwent three-point bending test and longitudinal compression test so as to measure the biomechanical changes after sterilization treatment, including the maximum load, ultimate strength, and elastic modulus. Three-point bending test showed that the levels of maximum load of the all experimental groups were lower than that of the control group, however, only those of the 3 Co-60 irradiation groups were significantly lower than that of the control group and that Co-60 radiation lowered the level of maximum load dose-dependently; and that the levels of ultimate strength of all the all experimental groups were lower than that of the control group, however, only those of the 3 Co-60 groups were significantly lower than that of the control group and that the higher the dosage of Co-60 radiation the lower the level of ultimate strength, however, not dose-dependently. The elastic modulus of the Co-60 25 KGy group was significantly higher than that of the control group, and there was no significant difference in the level of ultimate strength among the other groups. Longitudinal compression test showed that the levels of maximum load and ultimate strength of the 3 Co-60 irradiation groups, autoclave group, and circular ethylene groups were significantly lower than that of the control group, and there was no significant difference in elastic modulus among different groups. During sterilized package of CFRP products produced in quantity autoclave sterilization and Co-60 gamma ray irradiation sterilization should be avoided. Ethylene oxide is proposed as the best sterilization method. If gamma ray irradiation is to be used further technology improvement is necessary.

  2. Sterilization: women fit to be tied.

    PubMed

    Caress, B

    1975-01-01

    Sterilization abuse is both systematic and widespread. Frequently, women are misled about the dangers of surgery, misinformed about its permanence, and coerced while under the stress of labor or abortion. Generally, instances of abuses in the health system are treated as illegitimate, illegal aberations of an otherwise decent health care system. Careful examination of these so called abuses would reveal that each can be causally connected to particular aspects of the care of America's health system. Sterilization abuse stems from a combination of factors inherent in the health system plus 1 critical additional factor. Besides resulting from teaching and research imperatives, profit making, and the fee for service systems, such abuse is the most widespread example of medicine as an instrument of social control. Sterilization is the most extreme form of birth control and birth control is official US government policy. There were about 500,000 sterilizations performed on American women in 1973. None of the sterilization methods is innocuous, and each is associated with some physical and psychological side effects. General agreement exists in the medical literature that some risk is attendant to each procedure. Sterilization is the most dangerous and the fastest growing method of birth control. Since 1970 the figures show an almost 3-fold increase in the incidence of female sterilization, from 192,000 in 1970 to 548,000 in 1974. Much evidence exists to suggest that the increase in the number of sterilizations has fueled a trend toward the sterilization of younger women with fewer children. Official accommodation to liberalization of sterilization practices in the US came in 1969, when the American College of Obstetricians and Gynecologists (ACOG) withdrew its age parity formula. This liberalization of sterilization guidelines opened the floodgates to abuse. Some of the increase in the number of operations performed is due to increased demand, some of it is the result of misinformation and coercion. Training imperatives and political attitudes account for some of the increase in hysterectomies. Many young gynecologists in training have united their professional needs for training and their political ideas. Another reason for an increase in operations is greed. Doctors' attitudes toward sterilization and the misinformation about its impact stem from the same source: a change in government attitude toward population control. Although budget tightening is the byword for most government financed health care at this time, this is not the case for contraceptive services. Between 1967 and 1973 federal support for family planning services increased more than 1300%, from $11 million to $149 million. The growth of US spending for its birth control program abroad has been just as spectacular. Providing birth control services is population control. The line between voluntary and involuntary sterilization becomes thinner all the time.

  3. Soft electron processor for surface sterilization of food material

    NASA Astrophysics Data System (ADS)

    Baba, Takashi; Kaneko, Hiromi; Taniguchi, Shuichi

    2004-09-01

    As frozen or chilled foods have become popular nowadays, it has become very important to provide raw materials with lower level microbial contamination to food processing companies. Consequently, the sterilization of food material is one of the major topics for food processing. Dried materials like grains, beans and spices, etc., are not typically deeply contaminated by microorganisms, which reside on the surfaces of materials, so it is very useful to take low energetic, lower than 300 keV, electrons with small penetration power (Soft-Electrons), as a sterilization method for such materials. Soft-Electrons is researched and named by Dr. Hayashi et al. This is a non-thermal method, so one can keep foods hygienic without serious deterioration. It is also a physical method, so is free from residues of chemicals in foods. Recently, Nissin-High Voltage Co., Ltd. have developed and manufactured equipment for commercial use of Soft-Electrons (Soft Electron Processor), which can process 500 kg/h of grains. This report introduces the Soft Electron Processor and shows the results of sterilization of wheat and brown rice by the equipment.

  4. A strategy for the prevention of protein oxidation by drug product in polymer-based syringes.

    PubMed

    Nakamura, Koji; Abe, Yoshihiko; Kiminami, Hideaki; Yamashita, Arisa; Iwasaki, Kazuhiro; Suzuki, Shigeru; Yoshino, Keisuke; Dierick, William; Constable, Kevin

    2015-01-01

    Recently, new and advanced ideas have been presented on the value of polymer-based syringes for improved safety, better strength, reduced aggregation, and the prevention of drug degradation. In this report, our findings on drug degradation from protein oxidation will be presented and discussed. Commonly, dissolved oxygen is one of the factors for causing protein degradation. Due to the nature of higher gas permeability in polymer-based syringes, it was thought to be difficult to control the oxygen level during storage. However, this report demonstrates the appropriateness of combining the use of an oxygen absorber within the secondary packaging as a deoxygenated packaging system. In addition, this report suggests that another factor to enhance protein oxidization is related to radicals on the syringe barrel from sterilization by irradiation. We demonstrate that steam sterilization can minimize protein oxidization, as the protein filled in steam sterilized syringe is much more stable. In conclusion, the main oxidation pathway of a protein has been identified as dissolved oxygen and radical generation within a polymer container. Possible solutions are herewith presented for controlling oxidation by means of applying a deoxygenated packaging system as well as utilizing steam sterilization as a method of sterilization for prefillable polymer syringes. There have been many presentations and discussions about the risks associated with glass prefilled syringes. Advanced ideas are being presented on the value of polymer-based syringes for improved safety, better strength, reduced protein aggregation, and the prevention of drug degradation. Drug degradation based on protein oxidation is discussed in this report. Identification of the main factors causing this degradation and possible solutions available by using polymer-based syringes will be presented. The causes of protein oxidation have been identified as dissolved oxygen and radicals generated by the applied method of sterilization. The oxidation reaction created by dissolved oxygen within the drug product can be effectively inhibited by controlling the removal of the oxygen through the use of a deoxygenated packaging system. This packaging system can control the level or complete removal of oxygen from the primary container and the secondary packaging system. Protein oxidation induced by the formation of radicals from sterilization by irradiation is another critical aspect where it was thought that various sterilization methods were acceptable without loosing drug product quality. However, this report is first to demonstrate that gamma sterilized polymer-based syringes accelerated protein oxidation by radical generation; this effect can be prevented by means of steam sterilization. © PDA, Inc. 2015.

  5. Microbiological Sampling Methods and Sanitation of Edible Plants Grown on ISS

    NASA Technical Reports Server (NTRS)

    Parrish, Charles H. II; Khodadad, Christina L.; Garland, Nathaniel T.; Larson, Brian D.; Hummreick, Mary E.

    2013-01-01

    Pathogenic microbes on the surfaces of salad crops and growth chambers pose a threat to the health of crew on International Space Station. For astronauts to safely consume spacegrown vegetables produced in NASA's new vegetable production unit, VEGGIE, three technical challenges must be overcome: real-time sampling, microbiological analysis, and sanitation. Raphanus sativus cultivar Cherry Bomb II and Latuca sativa cultivar Outredgeous, two saled crops to be grown in VEGGIE, were inoculated with Salmonella enterica serovar Typhimurium (S. Typhimurium), a bacterium known to cause food-borne illness Tape- and swab-based sampling techniques were optimized for use in microgravity and assessed for effectiveness in recovery of bacteria from crop surfaces: Rapid pathogen detection and molecular analyses were performed via quantitative real-time polymerase chain reactiop using LightCycler® 480 and RAZOR® EX, a scaled-down instrument that is undergoing evaluation and testing for future flight hardware. These methods were compared with conventional, culture-based methods for the recovery of S. Typhimurium colonies. A sterile wipe saturated with a citric acid-based, food-grade sanitizer was applied to two different surface materials used in VEGGIE flight hardware that had been contaminated with the bacterium Pseudomonas aeruginosa,. another known human pathogen. To sanitize surfaces, wipes were saturated with either the sanitizer or sterile deionized water and applied to each surface. Colony forming units of P. aeruginosa grown on tryptic soy agar plates were enumerated from surface samples after sanitization treatments. Depending on the VEGGIE hardware material, 2- to 4.5-log10 reductions in colony-forming units were observed after sanitization. The difference in recovery of S. Typhimurium between tape- and swab- based sampling techniques was insignificant. RAZOR® EX rapidly detected S. Typhimurium present in both raw culture and extracted DNA samples.

  6. Genetic interactions underlying hybrid male sterility in the Drosophila bipectinata species complex.

    PubMed

    Mishra, Paras Kumar; Singh, Bashisth Narayan

    2006-06-01

    Understanding genetic mechanisms underlying hybrid male sterility is one of the most challenging problems in evolutionary biology especially speciation. By using the interspecific hybridization method roles of Y chromosome, Major Hybrid Sterility (MHS) genes and cytoplasm in sterility of hybrid males have been investigated in a promising group, the Drosophila bipectinata species complex that consists of four closely related species: D. pseudoananassae, D. bipectinata, D. parabipectinata and D. malerkotliana. The interspecific introgression analyses show that neither cytoplasm nor MHS genes are involved but X-Y interactions may be playing major role in hybrid male sterility between D. pseudoananassae and the other three species. The results of interspecific introgression analyses also show considerable decrease in the number of males in the backcross offspring and all males have atrophied testes. There is a significant positive correlation between sex - ratio distortion and severity of sterility in backcross males. These findings provide evidence that D. pseudoananassae is remotely related with other three species of the D. bipectinata species complex.

  7. Methods of dental instrument processing, sterilization, and storage--a review.

    PubMed

    Thomas, Lisa P; Bebermeyer, Richard D; Dickinson, Sharon K

    2005-10-01

    A comprehensive instrument processing and sterilization program in the dental office is essential to ensure that the DHCP and the public are protected from disease transmission due to contaminated instruments/ devices. The Centers for Disease Control and Prevention and other organizations have made recommendations to help dental personnel with this aspect of patient care. By following the CDC's latest guidelines, the DHCP can develop an optimal program of dental instrument processing, sterilization and storage.

  8. A novel method to scale up fungal endophyte isolations

    USDA-ARS?s Scientific Manuscript database

    Estimations of species diversity are influenced by sampling intensity which in turn is influenced by methodology. For fungal endophyte diversity studies, the methodology includes surface-sterilization prior to isolation of endophytes. Surface-sterilization is an essential component of fungal endophy...

  9. Female sterilization using an elasticated silicone ring.

    PubMed

    Cave, D G

    1979-06-16

    This paper presents the experience, in a District General Hospital, of using an elasticated silicone ring applied to the Fallopian tubes by the laparoscope. It is concluded that this is a safe and effective method of female sterilization, with good patient acceptance.

  10. Biological Sterilization of Returned Mars Samples

    NASA Technical Reports Server (NTRS)

    Allen, C. C.; Albert, F. G.; Combie, J.; Bodnar, R. J.; Hamilton, V. E.; Jolliff, B. L.; Kuebler, K.; Wang, A.; Lindstrom, D. J.; Morris, P. A.

    1999-01-01

    Martian rock and soil, collected by robotic spacecraft, will be returned to terrestrial laboratories early in the next century. Current plans call for the samples to be immediately placed into biological containment and tested for signs of present or past life and biological hazards. It is recommended that "Controlled distribution of unsterilized materials from Mars should occur only if rigorous analyses determine that the materials do not constitute a biological hazard. If any portion of the sample is removed from containment prior to completion of these analyses it should first be sterilized." While sterilization of Mars samples may not be required, an acceptable method must be available before the samples are returned to Earth. The sterilization method should be capable of destroying a wide range of organisms with minimal effects on the geologic samples. A variety of biological sterilization techniques and materials are currently in use, including dry heat, high pressure steam, gases, plasmas and ionizing radiation. Gamma radiation is routinely used to inactivate viruses and destroy bacteria in medical research. Many commercial sterilizers use Co-60 , which emits gamma photons of 1.17 and 1.33 MeV. Absorbed doses of approximately 1 Mrad (10(exp 8) ergs/g) destroy most bacteria. This study investigates the effects of lethal doses of Co-60 gamma radiation on materials similar to those anticipated to be returned from Mars. The goals are to determine the gamma dose required to kill microorganisms in rock and soil samples and to determine the effects of gamma sterilization on the samples' isotopic, chemical and physical properties. Additional information is contained in the original extended abstract.

  11. [Hysteroscopic tubal sterilization with Essure® devices: a retrospective descriptive study and evaluation of hypnosis].

    PubMed

    Gauchotte, E; Masias, C; Bogusz, N; Koebele, A

    2011-06-01

    The Essure(®) system is a hysteroscopic sterilization method. The aim of our study is to retrospectively evaluate the sterilization procedure with Essure(®) devices, with and without anesthesia, and in particular with hypnosis. The descriptive study includes all tubal sterilization with Essure(®) performed during the year 2009 at the Maternité régionale de Nancy. Hypnosis efficiency is retrospectively evaluated with Verbal Numeric Rating Scale (VNRS) for peroperative pain, and analgesic medication use for postoperative pain. Ninety-four sterilizations are performed, 85% (85/94) of them without anesthesia. The mean VNRS is 3.0. The mean operative time is 8.7 minutes, positively correlated with the VNRS (P=0.0005). The rate of successful insertion is 94%. At 3 months, 91% of the implants have a correct location. Inadequate locations are more frequent when anesthesia have been performed (37% vs 4%, P=0.016). There is no significant difference between groups with and without hypnosis for the VNRS, the failure rate and the use of analgesic medication. Tubal sterilization with the Essure(®) system is a quick and efficient method. Our study does not demonstrate efficiency of hypnosis in pain control. This remains to be explored with a prospective study, including others parameters, such as anxiety. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  12. Effect of Sterilization Methods on Electrospun Poly(lactic acid) (PLA) Fiber Alignment for Biomedical Applications.

    PubMed

    Valente, T A M; Silva, D M; Gomes, P S; Fernandes, M H; Santos, J D; Sencadas, V

    2016-02-10

    Medically approved sterility methods should be a major concern when developing a polymeric scaffold, mainly when commercialization is envisaged. In the present work, poly(lactic acid) (PLA) fiber membranes were processed by electrospinning with random and aligned fiber alignment and sterilized under UV, ethylene oxide (EO), and γ-radiation, the most common ones for clinical applications. It was observed that UV light and γ-radiation do not influence fiber morphology or alignment, while electrospun samples treated with EO lead to fiber orientation loss and morphology changing from cylindrical fibers to ribbon-like structures, accompanied to an increase of polymer crystallinity up to 28%. UV light and γ-radiation sterilization methods showed to be less harmful to polymer morphology, without significant changes in polymer thermal and mechanical properties, but a slight increase of polymer wettability was detected, especially for the samples treated with UV radiation. In vitro results indicate that both UV and γ-radiation treatments of PLA membranes allow the adhesion and proliferation of MG 63 osteoblastic cells in a close interaction with the fiber meshes and with a growth pattern highly sensitive to the underlying random or aligned fiber orientation. These results are suggestive of the potential of both γ-radiation sterilized PLA membranes for clinical applications in regenerative medicine, especially those where customized membrane morphology and fiber alignment is an important issue.

  13. Apparatus and method for preparing oxygen-15 labeled water H{sub 2}[{sup 15}O] in an injectable form for use in positron emission tomography

    DOEpatents

    Ferrieri, R.A.; Schlyer, D.J.; Alexoff, D.

    1996-01-09

    A handling and processing apparatus is revealed for preparing Oxygen-15 labeled water (H{sub 2}[{sup 15}O]) in injectable form for use in Positron Emission Tomography from preferably H{sub 2}[{sup 15}O] produced by irradiating a flowing gas target of nitrogen and hydrogen. The apparatus includes a collector for receiving and directing a gas containing H{sub 2}[{sup 15}O] gas and impurities, mainly ammonia (NH{sub 3}) gas into sterile water to trap the H{sub 2}[{sup 15}O] and form ammonium (NH{sub 4}{sup +}) in the sterile water. A device for displacing the sterile water containing H{sub 2}[{sup 15}O] and NH{sub 4}{sup +} through a cation resin removes NH{sub 4}{sup +} from the sterile water. A device for combining the sterile water containing H{sub 2}[{sup 15}O] with a saline solution produces an injectable solution. Preferably, the apparatus includes a device for delivering the solution to a syringe for injection into a patient. Also, disclosed is a method for preparing H{sub 2}[{sup 15}O] in injectable form for use in Positron Emission Tomography in which the method neither requires isotopic exchange reaction nor application of high temperature. 7 figs.

  14. Sterile-Insect Methods for Control of Mosquito-Borne Diseases: An Analysis

    PubMed Central

    Benedict, Mark; Bellini, Romeo; Clark, Gary G.; Dame, David A.; Service, Mike W.; Dobson, Stephen L.

    2010-01-01

    Abstract Effective vector control, and more specifically mosquito control, is a complex and difficult problem, as illustrated by the continuing prevalence (and spread) of mosquito-transmitted diseases. The sterile insect technique and similar methods control certain agricultural insect pest populations in a species-specific, environmentally sound, and effective manner; there is increased interest in applying this approach to vector control. Such an approach, like all others in use and development, is not a one-size-fits-all solution, and will be more appropriate in some situations than others. In addition, the proposed release of pest insects, and more so genetically modified pest insects, is bound to raise questions in the general public and the scientific community as to such a method's efficacy, safety, and sustainability. This article attempts to address these concerns and indicate where sterile-insect methods are likely to be useful for vector control. PMID:19725763

  15. Sterilization of Fusarium oxysporum by treatment of non-thermalequilibrium plasma in nutrient solution

    NASA Astrophysics Data System (ADS)

    Yasui, Shinji; Seki, Satoshi; Yoshida, Ryohei; Shoji, Kazuhiro; Terazoe, Hitoshi

    2016-01-01

    Fusarium wilt of spinach due to F. oxysporum infection is one of the most destructive root diseases in hydroponics in factories using the nutrient film technique. We investigated new technologies for the sterilization of microconidia of F. oxysporum by using a non-thermalequilibrium plasma treatment method in nutrient solution. Specifically, we investigated the sterilization capabilities of five types of gas (air, O2, N2, He, and Ar) used for plasma generation. The highest sterilization capability was achieved by using O2 plasma. However, ozone, which causes growth inhibition, was then generated and released into the atmosphere. The sterilization capability was lower when N2 or air plasma was used in the nutrient solution. It was confirmed that sterilization can be achieved by plasma treatment using inert gases that do not generate ozone; therefore, we determined that Ar plasma is the most preferable. In addition, we investigated the sterilization capabilities of other factors associated with Ar plasma generation, without direct plasma treatment. However, none of these other factors, which included Ar bubbling, pH reduction, increased temperature, hydrogen peroxide concentration, and UV radiation, could completely reproduce the results of direct plasma treatment. We assume that radicals such as O or OH may contribute significantly to the sterilization of microconidia of F. oxysporum in a nutrient solution.

  16. EPR STUDIES OF THERMALLY STERILIZED VASELINUM ALBUM.

    PubMed

    Ramos, Paweł; Pilawa, Barbara

    2015-01-01

    Electron paramagnetic resonance (EPR) spectroscopy was used for examination of free radicals in thermally treated vaselinum album (VA). Thermal treatment in hot air as sterilization process was tested. Conditions of thermal sterilization were chosen according to the pharmaceutical norms. Vaselinum album was heated at the following conditions (T--temperature, t--time): T = 160°C and t = 120 min, T = 170°C and t = 60 min and T = 180°C and t = 30 min. The aim of this work was to determine concentration and free radical properties of thermally sterilized VA. EPR analysis for VA was done 15 min after sterilization. EPR measurements were done at room temperature. EPR spectra were recorded in the range of microwave power of 2.2-70 mW. g-Factor, amplitudes (A) and line width (ΔBpp) of the spectra were determined. The shape of the EPR spectra was analyzed. Free radical concentration (N) in the heated samples was determined. EPR spectra were not obtained for the non heated VA. EPR spectra were detected for all thermally sterilized samples. The spectra revealed complex character, their asymmetry depends on microwave power. The lowest free radicals concentration was found for the VA sterilized at 180°C during 30 min. EPR spectroscopy is proposed as the method useful for optimization of sterilization process of drugs.

  17. Pain Associated With Hysteroscopic Sterilization

    PubMed Central

    Levy, Jenna; Childers, Meredith E.

    2007-01-01

    Background and Objectives: The safety and efficacy of female hysteroscopic sterilization using the Essure system has been well documented. Given the marked differences in the execution of hysteroscopic and laparoscopic sterilization, the objective of this study was to assess the experience of pain postprocedure between the 2. Secondary end-points included postoperative pain medication, time to return to normal activities, postprocedure bleeding, and patient satisfaction. Methods: Twenty cases each of laparoscopic sterilization (LS) and hysteroscopic sterilization (HS) were performed. Patients were surveyed regarding their experience of pain immediately postoperatively, 1 week, and 4 weeks post-procedure. Results: The average pain score immediately postprocedure was significantly lower among HS patients than among LS patients (t=−8.17, P<.0001). One-week post-procedure, none of the patients in the HS group reported any pain, while the average pain score among the LS patients was 2.65 (t =−9.67, P<.0001). Four weeks post-procedure, women in the HS group continued to report no pain, 35% of the LS group continued to report some pain (t=−3.04, P=.004). Conclusions: Hysteroscopic sterilization offers a minimally invasive, less painful, equally efficacious modality for sterilization than laparoscopic sterilization and should be available to all women seeking permanent birth control. PMID:17651558

  18. Using high-temperature formaldehyde sterilization as a model for studying gaseous sterilization.

    PubMed

    Mosley, Gregg A

    2008-01-01

    This study uses the high-temperature formaldehyde sterilization system provided by the Harvey Chemiclave, manufactured by Barnstead Thermolyne Corporation (Dubuque, IA), as a model to investigate certain phenomena associated with gaseous chemical sterilization systems. Although formaldehyde sterilization presents some unique and complex system attributes, the current studies provide helpful insights into general sterilization methods by chemicals in the gaseous state. Both population recovery and fraction negative (FN) techniques were used to assay surviving populations from biological indicators of the organism Geobacillus stearothermophilus following exposure to incremental Chemiclave cycles. Models 5500 and 6000 of the Barnstead/Thermolyne Chemiclave were used in the study. Reusable instruments such as scalers, explorers, and various hinged pieces were tested in minimum versus maximum load studies. Population recovery study results demonstrated that lethality rates increase with time throughout the Chemiclave sterilization process and that there are significant variations in lethality according to load location. The population recovery data in conjunction with the FN studies and temperature data confirm that one-half the full-cycle time is not a good estimator of one-half the full-cycle lethality because lethality curves are concave downward and lethality varies by load location. This conclusion can also be applied to other types of gaseous, chemical sterilization such as ethylene oxide. The work outlined in this study was a result of investigations into the parameters affecting formaldehyde chemical vapor sterilization with the Harvey Chemiclave sterilizer. During these studies, it became apparent that results clearly depicted the effects of continued acceleration of the rate of microbial lethality, as well as variations in delivered lethality as a function of position in the sterilizer load. This publication focuses on these observations because they are important considerations for understanding general concepts of sterilization efficacy in process applications. Erroneous conclusions can be drawn when one evaluates sterilization without a thorough understanding of affecting variables.

  19. Study of the desorption of ethylene oxide fixed on various materials during sterilization by a new procedure

    NASA Technical Reports Server (NTRS)

    Lacomme, M.; Chaigneau, M.; Lemoan, G.

    1977-01-01

    A continuous sterilization process using ethylene oxide was studied in comparison with a classical method in order to evaluate gas retention as a function of time and temperature on polyethylene, PVC, and rubber materials.

  20. Ethylene oxide sterilization: how hospitals can adapt to the changes.

    PubMed

    1994-12-01

    Ethylene oxide (EtO) gas sterilizers have been used by hospitals for over 40 years to sterilize surgical equipment and supplies that are heat sensitive or that cannot tolerate excessive moisture. However, in recent decades, EtO has been recognized as a potential mutagenic, reproductive, neurologic, and fire and explosion hazard to workers, and one agency has reportedly voted to classify EtO as carcinogenic to humans. Strict regulations concerning EtO exposure have been imposed by the Occupational Safety and Health Administration (OSHA), and the use of EtO, along with other toxic pollutants, is also being monitored by the Environmental Protection Agency (EPA) under the Clean Air Act. In addition, the use of chlorofluorocarbons (CFCs) as EtO diluents has focused attention on the EtO-CFC mixtures used in many sterilizers because CFCs have been linked to destruction of the ozone layer. Concerns about restrictive regulations related to these issues have prompted many hospitals to examine their use of EtO sterilization and propagated the misinformation that EtO sterilization is being phased out. In this article, we address some commonly asked questions regarding the use and regulation of EtO mixtures, as well as alternative sterilization agents and methods; provide two case studies illustrating how hospitals can evaluate various sterilization options; and summarize our conclusions and recommendations for hospitals facing decisions about sterilization techniques. For related topics, also see our Evaluation Update on endoscope reprocessors and our Hazard Report on improperly connected EtO-CFC cylinders to EtO sterilizers in this issue.

  1. One-step formation and sterilization of gellan and hyaluronan nanohydrogels using autoclave.

    PubMed

    Montanari, Elita; De Rugeriis, Maria Cristina; Di Meo, Chiara; Censi, Roberta; Coviello, Tommasina; Alhaique, Franco; Matricardi, Pietro

    2015-01-01

    The sterilization of nanoparticles for biomedical applications is one of the challenges that must be faced in the development of nanoparticulate systems. Usually, autoclave sterilization cannot be applied because of stability concerns when polymeric nanoparticles are involved. This paper describes an innovative method which allows to obtain, using a single step autoclave procedure, the preparation and, at the same time, the sterilization of self-assembling nanohydrogels (NHs) obtained with cholesterol-derivatized gellan and hyaluronic acid. Moreover, by using this approach, NHs, while formed in the autoclave, can be easily loaded with drugs. The obtained NHs dispersion can be lyophilized in the presence of a cryoprotectant, leading to the original NHs after re-dispersion in water.

  2. Hemodialysis-associated neutropenia and hypoxemia: the effect of dialyzer membrane materials.

    PubMed

    Hakim, R M; Lowrie, E G

    1982-01-01

    The fall in white blood cells (WBC) and arterial oxygen pressure that occurs during hemodialysis was investigated as a function of different dialysis membranes and different sterilization methods. 8 chronic hemodialysis patients were studied and each was dialyzed with three different membranes: cellulosic hollow fiber, polyacrylonitrile flat sheet and polymethylmethacrylate hollow fiber. Each dialyzer was studied with a dry sterilization method and after formalin treatment. Arterialized blood gas, bicarbonate and WBC were drawn at various intervals throughout dialysis. The effect of the sterilization method was minimal. Cellulosic membranes were shown to cause significantly more neutropenia (p less than 0.001) and hypoxemia (p less than 0.01) than the other two membranes. No significant differences was seen in pH, PCO2 and bicarbonate. The results indicate differences in biocompatibility between different membranes. Clinical implications are discussed.

  3. Protein sterilization method of firefly luciferase using reduced pressure and molecular sieves

    NASA Technical Reports Server (NTRS)

    Chappelle, E. W.; Rich, E., Jr. (Inventor)

    1973-01-01

    The sterilization of the protein fruitfly luciferase under conditions that prevent denaturation is examined. Denaturation is prevented by heating the protein in contact with molecular seives and under a reduced pressure of the order of 0.00005 millimeters of mercury.

  4. Effects of Terminal Sterilization on PEG-Based Bioresorbable Polymers Used in Biomedical Applications.

    PubMed

    Bhatnagar, Divya; Dube, Koustubh; Damodaran, Vinod B; Subramanian, Ganesan; Aston, Kenneth; Halperin, Frederick; Mao, Meiyu; Pricer, Kurt; Murthy, N Sanjeeva; Kohn, Joachim

    2016-10-01

    The effects of ethylene oxide (EO), vaporized hydrogen peroxide (VHP), gamma (γ) radiation, and electron-beam (E-beam) on the physiochemical and morphological properties of medical device polymers are investigated. Polymers with ether, carbonate, carboxylic acid, amide and ester functionalities are selected from a family of poly(ethylene glycol) (PEG) containing tyrosine-derived polycarbonates (TyrPCs) to include slow, medium, fast, and ultrafast degrading polymers. Poly(lactic acid) (PLA) is used for comparison. Molecular weight ( M w ) of all tested polymers decreases upon gamma and E-beam, and this effect becomes more pronounced at higher PEG content. Gamma sterilization increases the glass transition temperature of polymers with high PEG content. EO esterifies the carboxylic acid groups in desaminotyrosol-tyrosine (DT) and causes significant degradation. VHP causes hydroxylation of the phenyl ring, and hydrolytic degradation. This study signifies the importance of the chemical composition when selecting a sterilization method, and provides suggested conditions for each of the sterilization methods.

  5. Sterile working in ultrasonography: the use of dedicated ultrasound covers and sterile ultrasound gel.

    PubMed

    Marhofer, Peter; Fritsch, Gerhard

    2015-01-01

    Ultrasound is currently an important tool for diagnostic and interventional procedures. Ultrasound imaging provides significant advantages as compared to other imaging methods. The widespread use of ultrasound also carries the risk of drawbacks such as cross-infections. A large body of literature reports this possibly life-threatening side effect and specific patient populations are particularly at risk (e.g., neonates). Various methods of ultrasound probe disinfection are described; however, none of the mechanical or chemical probe disinfection procedures is optimal and, in particular, disinfection with high concentration of alcohol might be associated with ultrasound probe damage. The preparation of ultrasound probes with dedicated probe covers is a useful alternative for sterile working conditions. One ultrasound probe cover discussed in this paper is directly glued on to the ultrasound probe without the use of ultrasound coupling gel. By the use of sterile ultrasound coupling gel at the outer surface, additional effects on aseptic working conditions can be obtained.

  6. The context and limitations of female sterilization services in Pakistan.

    PubMed

    Khan, Adnan Ahmad; Khan, Ayesha; Abbas, Khadija; Tirmizi, Syed Farhan Ali; ul Islam, Zia

    2013-04-01

    Female sterilization has long been the most popular method of family planning (FP) in Pakistan, and yet most public health experts feel it contributes little to controlling family size or to population welfare. We used Pakistan Demographic Health Survey (PDHS) data to understand the role female sterilization plays in the overall context of FP in Pakistan. We performed a secondary analysis of data from the PDHS 1990-1 and 2006-7 to study factors that lead to sterilization and trends in the use of the procedure. In addition, census data were multiplied by proportions from PDHS data to estimate the number of women availing sterilization services. Around 1.9 million women in Pakistan are currently sterilized--up from 0.55 million in 1990-1, and around 173,867 undergo the procedure, annually. Women usually receive sterilization after 30 years of age (mean = 39) and after six children. The probability of sterilization increases with age, family size, and urban residence, and is unaffected by poverty, province of residence, or the woman or her husband's education. Most sterilizationis conducted in public sector facilities. Sterilization in Pakistan may be common, but occurs too late to have any significant effect on family size or benefit public health. Future avenues to make this option more useful to women and society would be to improve the repertoire and access and quality of FP services that are available, and to address governance issues that limit the performance and utility of government facilities.

  7. Sterilization of sea lampreys (Petromyzon marinus) by immersion in an aqueous solution of bisazir

    USGS Publications Warehouse

    Hanson, Lee H.

    1981-01-01

    Groups of sea lamprey (Petromyzon marinus) eggs fertilized by males previously immersed in an aqueous solution of p,p-bis(1-aziridinyl)-N-methylphosphinothioic amide (bisazir) at concentrations of 10–100 mg/L produced fewer normal, live prolarvae after 15–17 d of incubation than did groups of eggs fertilized by normal males. Mortality of embryos or prolarvae was nearly 100% in groups of eggs fertilized by males that had been immersed in a 50 mg/L solution of bisazir for 4 h or in a 100 mg/L solution for 2 h. The immersion technique appears to be an efficient method of sterilizing large numbers of male sea lampreys for use in a proposed sterile-male-release program.Key words: sea lamprey, Petromyzon marinus; pest control, fish control, sterile-male technique, sterilization, chemosterilants, bisazir, Great Lakes

  8. Medicalization, reproductive agency, and the desire for surgical sterilization among low-income women in urban Brazil.

    PubMed

    de Bessa, Gina Hunter

    2006-01-01

    This article draws on data from ethnographic fieldwork in an urban housing project to examine the social context and meanings of surgical sterilization for low-income women in Brazil. Low-income women resort to sterilization because they distrust or are unsatisfied with alternative methods and because it helps them to fulfill the requirements of modern, responsible motherhood. Although sterilization is an option among few alternatives, and one that has subjected women to greater medical management and intervention, I argue that sterilization also represents poor women's active struggle to improve their lives and to resist the burdens placed on them by unequal gender relations. This article contributes to a growing anthropological literature that demonstrates how reproduction has become a central site where social values are constituted and contested, and it details women's diverse responses to the process of medicalization.

  9. Rearing the Fruit Fly Drosophila melanogaster Under Axenic and Gnotobiotic Conditions.

    PubMed

    Koyle, Melinda L; Veloz, Madeline; Judd, Alec M; Wong, Adam C-N; Newell, Peter D; Douglas, Angela E; Chaston, John M

    2016-07-30

    The influence of microbes on myriad animal traits and behaviors has been increasingly recognized in recent years. The fruit fly Drosophila melanogaster is a model for understanding microbial interactions with animal hosts, facilitated by approaches to rear large sample sizes of Drosophila under microorganism-free (axenic) conditions, or with defined microbial communities (gnotobiotic). This work outlines a method for collection of Drosophila embryos, hypochlorite dechorionation and sterilization, and transfer to sterile diet. Sterilized embryos are transferred to sterile diet in 50 ml centrifuge tubes, and developing larvae and adults remain free of any exogenous microbes until the vials are opened. Alternatively, flies with a defined microbiota can be reared by inoculating sterile diet and embryos with microbial species of interest. We describe the introduction of 4 bacterial species to establish a representative gnotobiotic microbiota in Drosophila. Finally, we describe approaches for confirming bacterial community composition, including testing if axenic Drosophila remain bacteria-free into adulthood.

  10. Effects of Irradiation Dose on Sterility Induction and Quality Parameters of Drosophila suzukii (Diptera: Drosophilidae).

    PubMed

    Krüger, Alexandra Peter; Schlesener, Daniele Cristine Hoffmann; Martins, Liliane Nachtigall; Wollmann, Jutiane; Deprá, Maríndia; Garcia, Flávio Roberto Mello

    2018-04-02

    Drosophila suzukii (Matsumura, 1931) (Diptera: Drosophilidae) is a widely distributed pest of soft-skinned and stone fruits that is controlled mainly with pesticides. An alternative to the chemical control is the sterile insect technique (SIT), an ecologically friendly method of pest management that could be used against D. suzukii. The objective of the present study was to evaluate the effects of gamma radiation on reproductive sterility, ovarian morphometry, and quality parameters of D. suzukii. Full female sterility was achieved at 75 Gy, while an adequate level of male sterility (99.67%) was obtained at 200 Gy. The ovarian size showed an exponential decay in function of irradiation dose increase. There was no significant influence of irradiation dose on the quality parameters evaluated. Our data suggest that gamma radiation can be recommended to be used in an SIT program for D. suzukii.

  11. Sterilization validation for medical compresses at IRASM multipurpose irradiation facility

    NASA Astrophysics Data System (ADS)

    Alexandru, Mioara; Ene, Mihaela

    2007-08-01

    In Romania, IRASM Radiation Processing Center is the unique supplier of radiation sterilization services—industrial scale (ISO 9001:2000 and ISO 13485:2003 certified). Its Laboratory of Microbiological Testing is the sole third party competent laboratory (GLPractice License, ISO 17025 certification in progress) for pharmaceutics and medical devices as well. We here refer to medical compresses as a distinct category of sterile products, made from different kind of hydrophilic materials (cotton, non-woven, polyurethane foam) with or without an impregnated ointment base (paraffin, plant extracts). These products are included in the class of medical devices, but for the sterilization validation, from microbiological point of view, there are important differences in testing method compared to the common medical devices (syringes, catheters, etc). In this paper, we present some results and practical solutions chosen to perform a sterilization validation, compliant with ISO 11137: 2006.

  12. Study on a New Ultraviolet Sterilizer to the Surface Disinfection of the Ultrasound Probe.

    PubMed

    Chen, Gui Qiu; Chen, Yu Hao; Yi, Liang; Yin, Jin; Gao, Qiong; Song, Jiang Nan; Li, Shi Kang; Chen, Pei Hou; Guo, Gui Ping

    2018-02-01

    We studied the disinfection effect of a new ultraviolet (UV) sterilizer and its utilization on ultrasound probe surfaces. Carrier quantitative germicidal tests, simulated on-the-spot trials, and organic substance influence tests were used to carry out experimental observation. Artificially infected probes were disinfected using the sterilizer or a germicidal lamp for comparison. The total number and types of bacteria were determined and identified. Our results demonstrated the sterilizer had the best disinfection effect among three different disinfection methods in hospital. The sterilizer has been used in a hospital setting for 2 years with no notable damage to the ultrasound probe instrument. It has the advantages of fast disinfection, high disinfection effect, and good compatibility with the ultrasound instrument, worthy of being a promoted application in medical institutions. Copyright © 2018 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  13. Modelling Aedes aegypti mosquito control via transgenic and sterile insect techniques: endemics and emerging outbreaks.

    PubMed

    Seirin Lee, S; Baker, R E; Gaffney, E A; White, S M

    2013-08-21

    The invasion of pest insects often changes or destroys a native ecosystem, and can result in food shortages and disease endemics. Issues such as the environmental effects of chemical control methods, the economic burden of maintaining control strategies and the risk of pest resistance still remain, and mosquito-borne diseases such as malaria and dengue fever prevail in many countries, infecting over 100 million worldwide in 2010. One environmentally friendly method for mosquito control is the Sterile Insect Technique (SIT). This species-specific method of insect control relies on the mass rearing, sterilization and release of large numbers of sterile insects. An alternative transgenic method is the Release of Insects carrying a Dominant Lethal (RIDL). Our objective is to consider contrasting control strategies for two invasive scenarios via SIT and RIDL: an endemic case and an emerging outbreak. We investigate how the release rate and size of release region influence both the potential for control success and the resources needed to achieve it, under a range of conditions and control strategies, and we discuss advantageous strategies with respect to reducing the release resources and strategy costs (in terms of control mosquito numbers) required to achieve complete eradication of wild-type mosquitoes. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Liquid chromatographic method for determining the concentration of bisazir in water

    USGS Publications Warehouse

    Scholefield, Ronald J.; Slaght, Karen S.; Allen, John L.

    1997-01-01

    Barrier dams, traps, and lampricides are the techniques currently used by the Great Lakes Fishery Commission to control sea lampreys (Petromyzon marinus) in the Great Lakes. To augment these control techniques, a sterile-male-release research program was initiated at the Lake Huron Biological Station. Male sea lampreys were sterilized by intraperitoneal injection of the chemical sterilant P,P-bis(1-aziridinyl)-N-methylphosphinothioic amide (bisazir). An analytical method was needed to quantitate the concentration of bisazir in water and to routinely verify that bisazir (>25 μg/L) does not persist in the treated effluent discharged from the sterilization facility to Lake Huron. A rapid, accurate, and sensitive liquid chromatographic (LC) method was developed for determining bisazir in water. Bisazir was dissolved in Lake Huron water; extracted and concentrated on a C18 solid-phase extraction column; eluted with methanol; and quantitated by reversed-phase LC using a C18 column, a mobile phase of 70% water and 30% methanol (v/v), and UV detection (205 nm). Bisazir retention time was 7-8 min; total run time was about 20 min. Method detection limit for bisazir dissolved in Lake Huron water was about 15 μg/L. Recovery from Lake Huron water fortified with bisazir at 100 μg/L was 94% (95% confidence interval, 90.2-98.2%).

  15. Solid lipid nanoparticles for ocular drug delivery.

    PubMed

    Seyfoddin, Ali; Shaw, John; Al-Kassas, Raida

    2010-01-01

    Ocular drug delivery remains challenging because of the complex nature and structure of the eye. Conventional systems, such as eye drops and ointments, are inefficient, whereas systemic administration requires high doses resulting in significant toxicity. There is a need to develop novel drug delivery carriers capable of increasing ocular bioavailability and decreasing both local and systemic cytotoxicity. Nanotechnology is expected to revolutionize ocular drug delivery. Many nano-structured systems have been employed for ocular drug delivery and yielded some promising results. Solid lipid nanoparticles (SLNs) have been looked at as a potential drug carrier system since the 1990s. SLNs do not show biotoxicity as they are prepared from physiological lipids. SLNs are especially useful in ocular drug delivery as they can enhance the corneal absorption of drugs and improve the ocular bioavailability of both hydrophilic and lipophilic drugs. SLNs have another advantage of allowing autoclave sterilization, a necessary step towards formulation of ocular preparations. This review outlines in detail the various production, characterization, sterilization, and stabilization techniques for SLNs. In-vitro and in-vivo methods to study the drug release profile of SLNs have been explained. Special attention has been given to the nature of lipids and surfactants commonly used for SLN production. A summary of previous studies involving the use of SLNs in ocular drug delivery is provided, along with a critical evaluation of SLNs as a potential ocular delivery system.

  16. Effect of high pressure-high temperature process on meat product quality

    NASA Astrophysics Data System (ADS)

    Duranton, Frédérique; Marée, Elvire; Simonin, Hélène; Chéret, Romuald; de Lamballerie, Marie

    2011-03-01

    High pressure/high temperature (HPHT) processing is an innovative way to sterilize food and has been proposed as an alternative to conventional retorting. By using elevated temperatures and adiabatic compression, it allows the inactivation of vegetative microorganisms and pathogen spores. Even though the microbial inactivation has been widely studied, the effect of such process on sensorial attributes of food products, especially meat products, remains rare. The aim of this study was to investigate the potential of using HPHT process (500 MPa/115 °C) instead of conventional retorting to stabilize Toulouse sausages while retaining high organoleptic quality. The measurements of texture, color, water-holding capacity and microbial stability were investigated. It was possible to manufacture stable products at 500 MPa/115 °C/30 min. However, in these conditions, no improvement of the quality was found compared with conventional retorting.

  17. Optimizing novel penetration enhancing hybridized vesicles for augmenting the in-vivo effect of an anti-glaucoma drug.

    PubMed

    Naguib, Sarah S; Hathout, Rania M; Mansour, Samar

    2017-11-01

    Usually the topical delivery of ocular drugs poses a great challenge. Accordingly, the work in this study comprised the use of different hybrids of generally regarded as safe (GRAS) oils and surfactants in order to develop and optimize novel acetazolamide (AZD) entrapped-vesicular systems aiming at improving its ocular delivery and reaching better therapeutic outcomes in the treatment of glaucoma. The phospholipid/cholesterol bilayer of the vesicles was enriched with hybrids of Tween 80, Labrasol, Transcutol and Labrafac lipophile WL in different masses and proportions according to a mixture design viz. D-optimal mixture design. Three models were generated comprising three responses: particles size, percentage of entrapment efficiency and amount of drug released after 24 hours (Q24h). The results demonstrated the ability of the penetration enhancing hybrids in modulating the three responses compared to the conventional liposomes. Transmission electron microscope was used to characterize the selected formulations. Sterilization of selected formulations was carried out using gamma radiation and the effect of gamma radiations on entrapment, particle size and in vitro release were studied. The selected sterilized formulations were tested in-vivo on the eyes of albino rabbits in order to evaluate the efficiency of the novel delivery systems on the intra-ocular pressure reduction (IOP) compared to drug solution and the conventional liposomes. The novel formulations proved their efficiency in reducing the IOP to lower values compared to the conventional liposomes, which pose new successful platform for ocular delivery of AZD and other anti-glaucoma drug analogs.

  18. [Effects on performance of high-speed dental handpieces subjected to autoclaving].

    PubMed

    Deng, Xiao-hong; Sun, Zheng; Su, Jing; Qiao, Hong; Xiao, Xiao

    2006-07-01

    To investigate the effects on performances of high-speed dental handpieces subjected to autoclaving. The method of trial used to evaluate the effect of autoclaving included that ten chemical and ten biological indicators were arranged in each trial group being set by one sort of temperature and sterilization time. The range of temperature was from 100 degrees C to 134 degrees C and the sterilization time was from 1 to 45 minutes. The reliability of autoclaving was evaluated by the result of chemical indicator and the endospores of Bacillus stearothermophilus subjected to autoclaving. Ten newly imported and ten new domestic dental handpieces in two different brands were used to carry out this trial. The effects produced by autoclaving on performances of dental handpieces subjected to different type autoclaves were evaluated by some parameters. The eligible outcome in killing test of the 221 sterilized dental handpieces proved that the sterilization effect of autoclaving on dental handpieces was reliable. The chemical indicators showed that under the condition of 121 degrees C it needed 20 minutes to reach sterilization standard in the inner package and only 15 minutes on the outer package, and under the condition of 134 degrees C it took 4 minutes to reach sterilization standard in the inner package while only 2 minutes on the outer package. This outcome proved that material with package was more time-consuming than that without package during autoclaving. Autoclaving has positive effects on the performance of dental handpieces, while the autoclave with less-time full sterilization cycle has less effect on it. The performance of dental handpieces sterilized by the autoclave with 6-minute full sterilization cycle might be restorable within certain times of sterilization cycle. The sterilization effect of autoclaving is reliable. In order to reduce the influence on the performance of dental handpieces subjected to autoclaving, it should be reasonable to use the autoclave by which a full sterilization cycle might take less time and no use of package.

  19. Engineered selective plant male sterility through pollen-specific expression of the EcoRI restriction endonuclease.

    PubMed

    Millwood, Reginald J; Moon, Hong S; Poovaiah, Charleson R; Muthukumar, Balasubramaniam; Rice, John Hollis; Abercrombie, Jason M; Abercrombie, Laura L; Green, William Derek; Stewart, Charles Neal

    2016-05-01

    Unintended gene flow from transgenic plants via pollen, seed and vegetative propagation is a regulatory concern because of potential admixture in food and crop systems, as well as hybridization and introgression to wild and weedy relatives. Bioconfinement of transgenic pollen would help address some of these concerns and enable transgenic plant production for several crops where gene flow is an issue. Here, we demonstrate the expression of the restriction endonuclease EcoRI under the control of the tomato pollen-specific LAT52 promoter is an effective method for generating selective male sterility in Nicotiana tabacum (tobacco). Of nine transgenic events recovered, four events had very high bioconfinement with tightly controlled EcoRI expression in pollen and negligible-to-no expression other plant tissues. Transgenic plants had normal morphology wherein vegetative growth and reproductivity were similar to nontransgenic controls. In glasshouse experiments, transgenic lines were hand-crossed to both male-sterile and emasculated nontransgenic tobacco varieties. Progeny analysis of 16 000-40 000 seeds per transgenic line demonstrated five lines approached (>99.7%) or attained 100% bioconfinement for one or more generations. Bioconfinement was again demonstrated at or near 100% under field conditions where four transgenic lines were grown in close proximity to male-sterile tobacco, and 900-2100 seeds per male-sterile line were analysed for transgenes. Based upon these results, we conclude EcoRI-driven selective male sterility holds practical potential as a safe and reliable transgene bioconfinement strategy. Given the mechanism of male sterility, this method could be applicable to any plant species. © 2015 Society for Experimental Biology, Association of Applied Biologists and John Wiley & Sons Ltd.

  20. Conceptual framework and rationale

    PubMed Central

    Robinson, Alan S; Knols, Bart GJ; Voigt, Gabriella; Hendrichs, Jorge

    2009-01-01

    The sterile insect technique (SIT) has been shown to be an effective and sustainable genetic approach to control populations of selected major pest insects, when part of area-wide integrated pest management (AW-IPM) programmes. The technique introduces genetic sterility in females of the target population in the field following their mating with released sterile males. This process results in population reduction or elimination via embryo lethality caused by dominant lethal mutations induced in sperm of the released males. In the past, several field trials have been carried out for mosquitoes with varying degrees of success. New technology and experience gained with other species of insect pests has encouraged a reassessment of the use of the sterility principle as part of integrated control of malaria vectors. Significant technical and logistic hurdles will need to be overcome to develop the technology and make it effective to suppress selected vector populations, and its application will probably be limited to specific ecological situations. Using sterile males to control mosquito vector populations can only be effective as part of an AW-IPM programme. The area-wide concept entails the targeting of the total mosquito population within a defined area. It requires, therefore, a thorough understanding of the target pest population biology especially as regards mating behaviour, population dynamics, dispersal and level of reproductive isolation. The key challenges for success are: 1) devising methods to monitor vector populations and measuring competitiveness of sterile males in the field, 2) designing mass rearing, sterilization and release strategies that maintain competitiveness of the sterile male mosquitoes, 3) developing methods to separate sexes in order to release only male mosquitoes and 4) adapting suppression measures and release rates to take into account the high reproductive rate of mosquitoes. Finally, success in area-wide implementation in the field can only be achieved if close attention is paid to political, socio-economic and environmental sensitivities and an efficient management organization is established taking into account the interests of all potential stakeholders of an AW-IPM programme. PMID:19917070

  1. Vasectomy--an international appraisal.

    PubMed

    Johnson, J H

    1983-01-01

    Although an estimated 100 million couples who practice contraception have chosen sterilization as their accepted method, the overwhelming majority of the sterilizations were obtained by women even though vasectomy is known to be simpler, safer and cheaper than tubal ligation. In an effort to stimulate new interest in male sterilization an international meeting was held in Sri Lanka in 1982. 66 participants from 25 countries discussed problems related to the acceptance of vasectomy and the delivery of sterilization services. Yearly vasectomy figures have fluctuated widely and are attributed to new simplified female procedures, fluctuating government policies, erratic funding and male chauvinism. Machismo in Central and South America were of particular concern. The use of paramedics to perform vasectomies in areas where there are few overworked doctors was debated. It was concluded that quality services were essential and both physicians and paramedics may have to be used. In Africa neither the population nor the government is interested in male sterilization and contraception is considered woman's business. Several gynecologists are just beginning to introduce the male role in contraception. In Thailand, vasectomy is widely promoted and rewarded, and additional mass market techniques were suggested. Some countries have given cash payments for the procedure, but the conference participants were in favor of more indirect motivational methods. The conference concluded that promoting vasectomy will require more information, education and effort than female sterilization. In particular erroneous fears of castration and impotence must be overcome. Word of mouth communication was judged to be the best way of promoting the success of the procedure.

  2. Compulsory Birth Control and Fertility Measures in India.

    ERIC Educational Resources Information Center

    Halli, S. S.

    1983-01-01

    Discussion of possible applications of the microsimulation approach to analysis of population policy proposes compulsory sterilization policy for all of India. Topics covered include India's population problem, methods for generating a distribution of couples to be sterilized, model validation, data utilized, data analysis, program limitations,…

  3. 40 CFR 63.365 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES Ethylene Oxide... amount of ethylene oxide, for the duration of the first evacuation under normal operating conditions (i.e., sterilization pressure and temperature). (i) The amount of ethylene oxide loaded into the sterilizer (Wc) shall...

  4. Effects of sterilization processes on NiTi alloy: surface characterization.

    PubMed

    Thierry, B; Tabrizian, M; Savadogo, O; Yahia, L

    2000-01-01

    Sterilization is required for using any device in contact with the human body. Numerous authors have studied device properties after sterilization and reported on bulk and surface modifications of many materials after processing. These surface modifications may in turn influence device biocompatibility. Still, data are missing on the effect of sterilization procedures on new biomaterials such as nickel-titanium (NiTi). Herein we report on the effect of dry heat, steam autoclaving, ethylene oxide, peracetic acid, and plasma-based sterilization techniques on the surface properties of NiTi. After processing electropolished NiTi disks with these techniques, surface analyses were performed by Auger electron spectroscopy (AES), atomic force microscopy (AFM), and contact angle measurements. AES analyses revealed a higher Ni concentration (6-7 vs. 1%) and a slightly thicker oxide layer on the surface for heat and ethylene oxide processed materials. Studies of surface topography by AFM showed up to a threefold increase of the surface roughness when disks were dry heat sterilized. An increase of the surface energy of up to 100% was calculated for plasma treated surfaces. Our results point out that some surface modifications are induced by sterilization procedures. Further work is required to assess the effect of these modifications on biocompatibility, and to determine the most appropriate methods to sterilize NiTi. Copyright 2000 John Wiley & Sons, Inc.

  5. The Effect of Autoclave Sterilization on Resistance to Cyclic Fatigue of Hero Endodontic File #642 (6%) at Two Artificial Curvature

    PubMed Central

    Khabiri, Masoud; Ebrahimi, Maziar; Saei, Mohammad Reza

    2017-01-01

    Statement of the Problem: File fracture can interfere with cleaning and shaping of the canal and compromise periradicular healing. Autoclave sterilization may prone the files to fracture. Purpose: The purpose of the present study was to determine the effect of autoclave sterilization on the cyclic fatigue resistance of Hero642 rotary instrument in two curvatures of 45 and 60 degrees. Materials and Method: For this experimental in-vitro study, 90 Nickel-Titanium HERO 642 rotary files #30 with 0.06 taper were selected. They were divided into two groups (curvature of 45 and 60 degree) of 45 files. Each group was then subdivided into 3 subgroups; group I: no sterilization, group II: 5 cycles of sterilization and group III: 10 cycles of sterilization. Files were used in artificial canals until fracture. The cyclic fatigue was measured as the number of cycles before fracture. The data was statically analyzed by Student’s t-test and two-way analysis of variance. Results: There was a significant difference in cyclic fatigue of two curvature of 45 and 60 degrees (p= 0.001). However, sterilization process has no significant effect on cyclic fatigue of HERO files (p= 0.557). Conclusion: Sterilization had no effect on the cyclic fatigue of HERO 642 files when used in curvature of 45 or 60 degrees. PMID:29201971

  6. Differences in fate, behavior and uptake of conventional- and nano-pesticides

    NASA Astrophysics Data System (ADS)

    Anuar, M. Firdaus Mohd; E Hodson, Mark; Boxall, Alistair BA

    2017-04-01

    Nanopesticides, in which conventional pesticides are designed into nanoparticles, are now available and are marketed as having improved longevity and efficacy in the environment. Nanoparticles are known to have different properties to dissolved chemicals and as such it is possible that the fate and behaviour of nanopesticides differs from conventional pesticides. We present work on the synthetic pyrethroid bifenthrin to explore the implications of nanoencapsulation for the sorption, persistence and uptake of the active ingredient in soil-earthworm systems. Studies were done using the active ingredient, a traditional formulation and two nanoformulations. In adsorption experiments conducted using five soils with a range of properties (pH 4.7 - 7.7; % organic carbon 1.2 - 5.2; texture silt loam to loamy sand), adsorption was well described by linear isotherms. Adsorption of analytical grade bifenthrin (Kd = 1800 - 7200 mL / g) was greater than that of a commercial formulation (Kd = 190 - 470 mL / g) which in turn was greater than that of nanoformulations (Kd = 52 - 150 mL / g). For all bifenthrin types adsorption increased with increasing soil organic matter content. Degradation rates of the analytical grade bifenthrin and commercial formulation were similar and faster than those of nanoformulations. Degradation rates were faster in non-sterile compared to sterile conditions. These results suggest that nano-encapsulation could lead to increased mobility and persistence of bifenthrin in the environment and therefore potentially increased exposure and bioavailability. To investigate the effects of nanoencapsulation on uptake we carried out a series of uptake and excretion experiments using the earthworms Eisenia fetida and Lumbricus terrestris. Over the exposure period the concentration of bifenthrin in the soil decreased and increased in the earthworms. Rates of accumulation and excretion were greater for the nanobifenthrin than the non-nanoformulation and active ingredient. Dissection and analysis of earthworm tissues indicated that the accumulated bifenthrin from the nano exposure was concentrated in the earthworm gut whereas the accumulated bifenthrin in the conventional exposure was concentrated in the earthworm tissues. We used kinetic modelling to determine bioconcentration factors. The higher accumulation and excretion rates result in predicted lower bioconcentration factors for the nanobofenthrin compared to the conventional and analytical grade forms. Our experiments demonstrate the differing behaviours of a conventional and nano-formluated pesticide therefore suggesting that current environmental risk assessment methodologies for conventional pesticides may not be appropriate for nanoformulations.

  7. Contraceptive practice in China: 1970-2004.

    PubMed

    Wang, Cuntong

    2015-03-01

    Using large-scale data from the national conventional statistics and nationally representative sample surveys, the current study aims to assess the level, mode, and determinants of modern contraceptive use from 1970 to 2004 among married couples aged 20 to 49 years in China. A relatively stable Chinese mode of contraception has been established and maintained since the 1980s, characterized by prominent, long-acting contraceptive use and the highest overall prevalence in the world during the past 3 decades. In recent years, the composition of contraceptive use has changed, characterized by the increasing use of the intrauterine device and short-acting methods and a drastic decrease in male and female sterilization. However, the dominance of the long-acting methods has not undergone substantial change. The results from a multinomial logit model employed in this study indicate that family planning policy and socioeconomic and demographic factors jointly influence contraceptive choice. In particular, contraceptive choice is closely associated with the strength of family planning policy in China. © 2011 APJPH.

  8. Survey of Sterile Admixture Practices in Canadian Hospital Pharmacies: Part 2. More Results and Discussion

    PubMed Central

    Warner, Travis; Nishi, Cesilia; Checkowski, Ryan; Hall, Kevin W

    2009-01-01

    Background: The 1996 Guidelines for Preparation of Sterile Products in Pharmacies of the Canadian Society of Hospital Pharmacists (CSHP) represent the current standard of practice for sterile compounding in Canada. However, these guidelines are practice recommendations, not enforceable standards. Previous surveys of sterile compounding practices have shown that actual practice deviates markedly from voluntary practice recommendations. In 2004, the United States Pharmacopeia (USP) published its “General Chapter <797> Pharmaceutical Compounding—Sterile Preparations”, which set a more rigorous and enforceable standard for sterile compounding in the United States. Objectives: To assess sterile compounding practices in Canadian hospital pharmacies and to compare them with current CSHP recommendations and USP chapter <797> standards. Methods: An online survey, based on previous studies of sterile compounding practices, the CSHP guidelines, and the chapter <797> standards, was created and distributed to 193 Canadian hospital pharmacies. Results: A total of 133 pharmacies completed at least part of the survey, for a response rate of 68.9%. All respondents reported the preparation of sterile products. Various degrees of deviation from the practice recommendations were noted for virtually all areas of the CSHP guidelines and the USP standards. Low levels of compliance were most notable in the areas of facilities and equipment, process validation, and product testing. Availability in the central pharmacy of a clean room facility meeting or exceeding the criteria of International Organization for Standardization (ISO) class 8 is a requirement of the chapter <797> standards, but more than 40% of responding pharmacies reported that they did not have such a facility. Higher levels of compliance were noted for policies and procedures, garbing requirements, aseptic technique, and handling of hazardous products. The survey methods for this study and results relating to policies, personnel, raw materials, storage and handling, facilities and equipment, and garments were reported in Part 1. Part 2 reports results relating to preparation of aseptic products, expiry dating, labelling, process validation, product testing and release, documentation, records, and disposal of hazardous pharmaceuticals. It also highlights some of the key areas where there is considerable opportunity for improvement. Conclusion: This survey identified numerous deficiencies in sterile compounding practices in Canadian hospital pharmacies. Awareness of these deficiencies may create an impetus for critical assessment and improvements in practice. PMID:22478890

  9. Survey of sterile admixture practices in canadian hospital pharmacies: part 1. Methods and results.

    PubMed

    Warner, Travis; Nishi, Cesilia; Checkowski, Ryan; Hall, Kevin W

    2009-03-01

    The 1996 Guidelines for Preparation of Sterile Products in Pharmacies of the Canadian Society of Hospital Pharmacists (CSHP) represent the current standard of practice for sterile compounding in Canada. However, these guidelines are practice recommendations, not enforceable standards. Previous surveys of sterile compounding practices have shown that actual practice deviates markedly from voluntary practice recommendations. In 2004, the United States Pharmacopeia (USP) published its "General Chapter <797> Pharmaceutical Compounding-Sterile Preparations", which set a more rigorous and enforceable standard for sterile compounding in the United States. To assess sterile compounding practices in Canadian hospital pharmacies and to compare them with current CSHP recommendations and USP chapter <797> standards. An online survey, based on previous studies of sterile compounding practices, the CSHP guidelines, and the chapter <797> standards, was created and distributed to 193 Canadian hospital pharmacies. A total of 133 pharmacies completed at least part of the survey, for a response rate of 68.9%. All respondents reported the preparation of sterile products. Various degrees of deviation from the practice recommendations were noted for virtually all areas of the CSHP guidelines and the USP standards. Low levels of compliance were most notable in the areas of facilities and equipment, process validation, and product testing. Availability in the central pharmacy of a clean room facility meeting or exceeding the criteria of International Organization for Standardization (ISO) class 8 is a requirement of the chapter <797> standards, but more than 40% of responding pharmacies reported that they did not have such a facility. Higher levels of compliance were noted for policies and procedures, garbing requirements, aseptic technique, and handling of hazardous products. Part 1 of this series reports the survey methods and results relating to policies, personnel, raw materials, storage and handling, facilities and equipment, and garments. Part 2 will report results relating to preparation of aseptic products, expiry dating, labelling, process validation, product testing and release, documentation, records, and disposal of hazardous pharmaceuticals. It will also highlight some of the key areas where there is considerable opportunity for improvement. This survey identified numerous deficiences in sterile compounding practices in Canadian hospital pharmacies. Awareness of these deficiencies may create an impetus for critical assessment and improvements in practice.

  10. Knowledge and attitudes about long-acting reversible contraception among Latina women who desire sterilization

    PubMed Central

    White, Kari; Hopkins, Kristine; Potter, Joseph E.; Grossman, Daniel

    2013-01-01

    Background There is growing interest in increasing the use of long-acting reversible contraception (LARC), and suggestions that such methods may serve as an alternative to sterilization. However, there is little information about whether women who do not want more children would be interested in using LARC methods. Methods We conducted semi-structured interviews with 120 parous Latina women in El Paso, Texas who wanted a sterilization but had not obtained one. We assessed women’s awareness of and interest in using the copper intrauterine device (IUD), levonorgestrel intrauterine system (LNG-IUS), and etonogestrel implant. Findings Overall, 51%, 23% and 47% of women reported they had heard of the copper IUD, LNG-IUS and implant, respectively. More women stated they would use the copper IUD (24%) than the LNG-IUS (14%) or implant (9%). Among women interested in LARC, the most common reasons were that, relative to their current method, LARC methods were more convenient, effective, and provided longer-term protection against pregnancy. Those who had reservations about LARC were primarily concerned with menstrual changes. Women also had concerns about side effects and the methods' effectiveness in preventing pregnancy, preferring to use a familiar method. Conclusions Although these findings indicate many Latina women in this setting do not consider LARC an alternative to sterilization, they point to an existing demand among some who wish to end childbearing. Efforts are needed to improve women’s knowledge and access to a range of methods so they can achieve their childbearing goals. PMID:23816156

  11. Current techniques and outcomes in hysteroscopic sterilization: current evidence, considerations, and complications with hysteroscopic sterilization micro inserts.

    PubMed

    Casey, James; Cedo-Cintron, Laura; Pearce, Jessica; Yunker, Amanda

    2017-08-01

    To describe the current data regarding effectiveness, complications, postoperative evaluation, and surgical interventions associated with Essure hysteroscopic sterilization. Hysteroscopic sterilization is a commonly performed procedure that is offered as a well tolerated, effective, outpatient method of permanent sterilization. Over the past several years, concerns have been raised regarding correct placement and postoperative complications. This has led to statements by both the Food and Drug Administration (FDA) in October, 2016 and American Association of Gynecologic Laparoscopists in February, 2017, as a significant portion of women seek removal of these devices. A current black-box warning issued by the FDA in 2016 recommends discussion of 'the probabilities of rates or events' of adverse outcomes associated with Essure placement. Although hysteroscopic sterilization is usually a safe, effective option for permanent contraception, new evidence regarding complications has emphasized the need for proper education and counseling. Appropriate patient selection and knowledge of potential complications is paramount to ensuring patients, and medical providers are well informed and have realistic expectations regarding potential placement and postoperative issues.

  12. Allograft update: the current status of tissue regulation, procurement, processing, and sterilization.

    PubMed

    McAllister, David R; Joyce, Michael J; Mann, Barton J; Vangsness, C Thomas

    2007-12-01

    Allografts are commonly used during sports medicine surgical procedures in the United States, and their frequency of use is increasing. Based on surgeon reports, it is estimated that more than 60 000 allografts were used in knee surgeries by members of the American Orthopaedic Society for Sports Medicine in 2005. In the United States, there are governmental agencies and other regulatory bodies involved in the oversight of tissue banks. In 2005, the Food and Drug Administration finalized its requirements for current good tissue practice and has mandated new rules regarding the "manufacture" of allogenic tissue. In response to well-publicized infections associated with the implantation of allograft tissue, some tissue banks have developed methods to sterilize allograft tissue. Although many surgeons have significant concerns about the safety of allografts, the majority believe that sterilized allografts are safe but that the sterilization process negatively affects tissue biology and biomechanics. However, most know very little about the principles of sterilization and the proprietary processes currently used in tissue banking. This article will review the current status of allograft tissue regulation, procurement, processing, and sterilization in the United States.

  13. Evaluation of Ophthalmic Surgical Instrument Sterility Using Short-Cycle Sterilization for Sequential Same-Day Use.

    PubMed

    Chang, David F; Hurley, Nikki; Mamalis, Nick; Whitman, Jeffrey

    2018-03-27

    The common practice of short-cycle sterilization for ophthalmic surgical instrumentation has come under increased regulatory scrutiny. This study was undertaken to evaluate the efficacy of short-cycle sterilization processing for consecutive same-day cataract procedures. Testing of specific sterilization processing methods by an independent medical device validation testing laboratory. Phaco handpieces from 3 separate manufacturers were tested along with appropriate biologic indicators and controls using 2 common steam sterilizers. A STATIM 2000 sterilizer (SciCan, Canonsburg, PA) with the STATIM metal cassette, and an AMSCO Century V116 pre-vacuum sterilizer (STERIS, Mentor, OH) using a Case Medical SteriTite container (Case Medical, South Hackensack, NJ) rigid container were tested using phaco tips and handpieces from 3 different manufacturers. Biological indicators were inoculated with highly resistant Geobacillus stearothermophilus, and each sterility verification test was performed in triplicate. Both wrapped and contained loads were tested with full dry cycles and a 7-day storage time to simulate prolonged storage. In adherence with the manufacturers' instructions for use (IFU), short cycles (3.0-3.5-minute exposure times) for unwrapped and contained loads were also tested after only 1 minute of dry time to simulate use on a consecutive case. Additional studies were performed to demonstrate whether any moisture present in the load containing phaco handpieces postprocessing was sterile and would affect the sterility of the contents after a 3-minute transit/storage time. This approximated the upper limit of time needed to transfer a containment device to the operating room. Presence or absence of microbial growth from cultured test samples. All inoculated test samples from both sterilizers were negative for growth of the target organism whether the full dry phase was interrupted or not. Pipetted postprocessing moisture samples and swabs of the handpieces were also negative for growth after a 3-minute transit/storage time. These studies support the use of unwrapped, short-cycle sterilization that adheres to the IFU of these 2 popular Food and Drug Administration-cleared sterilizers for sequential same-day cataract surgeries. A full drying phase is not necessary when the instruments are kept within the covered sterilizer containment device for prompt use on a sequential case. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  14. Evaluation of microbial contamination associated with different preparation methods for neonatal intravenous fat emulsion infusion.

    PubMed

    Crill, Catherine M; Hak, Emily B; Robinson, Lawrence A; Helms, Richard A

    2010-06-01

    Microbial contamination associated with different methods of neonatal intravenous fat emulsion (IVFE) preparation and delivery was evaluated. Sterility testing was performed on IVFE dispensed via three different methods: (1) in the original container (n = 60), (2) repackaged into a syringe (n = 90), and (3) drawdown of the original container (n = 60). At the end of each infusion (24 hours for methods 1 and 3, 12 hours for method 2), a sample of the IVFE was withdrawn from the container using a sterile syringe in an International Organization for Standardization class 5 hood and sent to the hospital microbiology laboratory, where the samples were introduced into blood culture bottles and incubated for five days. Each sample was then subcultured on a blood agar plate with olive oil and left for an additional two days in a carbon dioxide incubator to assess for Malassezia furfur. None of the samples from the original containers showed bacterial or fungal growth. Three of the samples from syringes had bacterial growth (two samples contained coagulase-negative staphylococcus and one contained both Klebsiella oxytoca and Citrobacter freundii), yielding a contamination rate of 3.3%. The number of contaminated samples did not significantly differ among the three preparation methods (p = 0.13). Repackaging IVFE into sterile syringes resulted in bacterial contamination and should be avoided in clinical practice. IVFE samples obtained using the drawdown procedure under sterile conditions for infusion over 24 hours revealed no microbial contamination.

  15. Baby bottle steam sterilizers for disinfecting home nebulizers inoculated with non-tuberculous mycobacteria.

    PubMed

    Towle, D; Callan, D A; Lamprea, C; Murray, T S

    2016-03-01

    Non-tuberculous mycobacteria (NTMb), present in environmental water sources, can contribute to respiratory infection in patients with chronic pulmonary disease. Contaminated nebulizers are a potential source of respiratory infection. Treatment with baby bottle steam sterilizers disinfects home nebulizers inoculated with bacterial pathogens but whether this method works for disinfection of NTMb is unclear. Baby bottle steam sterilization was compared with vigorous water washing for disinfecting home nebulizers inoculated with NTMb mixed with cystic fibrosis sputum. No NTMb was recovered from any nebulizers after steam treatment whereas viable NTMb grew after water washing, demonstrating that steam sterilization effectively disinfects NTMb-inoculated nebulizers. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  16. The role of the gastrointestinal microbiome in Helicobacter pylori pathogenesis

    PubMed Central

    Sheh, Alexander; Fox, James G

    2013-01-01

    The discovery of Helicobacter pylori overturned the conventional dogma that the stomach was a sterile organ and that pH values < 4 were capable of sterilizing the stomach. H. pylori are an etiological agent associated with gastritis, hypochlorhydria, duodenal ulcers, and gastric cancer. It is now appreciated that the human stomach supports a bacterial community with possibly 100s of bacterial species that influence stomach homeostasis. Other bacteria colonizing the stomach may also influence H. pylori-associated gastric pathogenesis by creating reactive oxygen and nitrogen species and modulating inflammatory responses. In this review, we summarize the available literature concerning the gastric microbiota in humans, mice, and Mongolian gerbils. We also discuss the gastric perturbations, many involving H. pylori, that facilitate the colonization by bacteria from other compartments of the gastrointestinal tract, and identify risk factors known to affect gastric homeostasis that contribute to changes in the microbiota. PMID:23962822

  17. Consolidation of degraded ornamental porous limestone stone by calcium carbonate precipitation induced by the microbiota inhabiting the stone.

    PubMed

    Jimenez-Lopez, C; Rodriguez-Navarro, C; Piñar, G; Carrillo-Rosúa, F J; Rodriguez-Gallego, M; Gonzalez-Muñoz, M T

    2007-08-01

    Although it has already been shown that calcareous stone can be consolidated by using a bacterially inoculated culture medium, a more user-friendly method is the in situ application of a sterile culture medium that is able to activate, among the microbial community of the stone, those bacteria with a potential for calcium carbonate precipitation. In order to test this new method for stone consolidation, non-sterilized decayed porous limestone was immersed in sterile nutritional media. Results were compared to those of the runs in which stone sterilized prior to the treatment was used. The effects of the microbial community on stone consolidation were determined by recording the evolution of the culture media chemistry. The treated stone was tested for mechanical resistance and porosity. Results demonstrate that the tested media were able to activate bacteria from the microbial community of the stone. As a consequence of the growth of these bacteria, an alkalinization occurred that resulted in calcium carbonate precipitation. The new precipitate was compatible with the substrate and consolidated the stone without pore plugging. Therefore, a good candidate to in situ consolidate decayed porous limestone is the application of a sterile culture medium with the characteristics specified in the present study.

  18. CASE STUDY 6.26: UNSUCCESSFUL TOXICITY IDENTIFICATION AND EVALUATIONS MANIPULATIONS: SEAWATER BUFFERS AND STERILIZATION METHODS

    EPA Science Inventory

    This paper summarizes several unsuccessful attempts to develop Toxicity Identification and Evaluation (TIE) manipulations for aqueous samples during the first 5 years of our research. The first part of the paper explores irradiation as a sterilization technique to discern if sam...

  19. Agrobacterium rhizogenes - based transformation of soybean roots to form composite plants

    USDA-ARS?s Scientific Manuscript database

    Composite plants are a powerful tool to rapidly analyze the effects of gene overexpression, gene silencing, and examine test promoter expression in transgenic roots. No sterile tissue culture is needed. This avoids loss of valuable material due to contamination of sterile cultures. This method uses ...

  20. Gender Differences in Perception of Contraception Alternatives by Never-Married College Students.

    ERIC Educational Resources Information Center

    McDermott, Robert J.; Gold, Robert S.

    A study examined the perceptions of college students regarding 10 contraceptive methods, including the condom, douche, oral contraceptive, withdrawal, diaphragm, female sterilization, spermicidal foam, rhythm, male sterilization, and intrauterine device. A total of 285 females and 316 males responded to a questionnaire which had students rank each…

  1. Production of a maternal-zygotic medaka mutant using hybrid sterility.

    PubMed

    Shimada, Atsuko; Takeda, Hiroyuki

    2008-08-01

    Taking advantage of the characteristics that make hybrids between Japanese and Chinese medaka grow well, albeit sterile, we have developed a method of germ-line replacement in which these hybrids are used as hosts for the production of a maternal-zygotic mutant. The protocol is described herein.

  2. Evaluation of Various Cleaning Methods to Remove Bacillus Spores from Spacecraft Hardware Materials

    NASA Technical Reports Server (NTRS)

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-01-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.

  3. Prevalence and Clinical Significance of Sterile Intra-amniotic Inflammation in Patients with Preterm Labor and Intact Membranes

    PubMed Central

    Romero, Roberto; Miranda, Jezid; Chaiworapongsa, Tinnakorn; Korzeniewski, Steven J.; Chaemsaithong, Piya; Gotsch, Francesca; Dong, Zhong; Ahmed, Ahmed I.; Yoon, Bo Hyun; Hassan, Sonia S.; Kim, Chong J.; Yeo, Lami

    2014-01-01

    Problem Inflammation and infection play a major role in preterm birth. The purpose of this study was to: 1) determine the prevalence and clinical significance of sterile intra-amniotic inflammation; and 2) examine the relationship between amniotic fluid (AF) concentrations of high mobility group box-1 (HMGB1) and the interval from amniocentesis-to-delivery in patients with sterile intra-amniotic inflammation. Method of Study AF samples obtained from 135 women with preterm labor and intact membranes were analyzed using cultivation techniques as well as broad-range PCR and mass spectrometry (PCR/ESI-MS). Sterile intra-amniotic inflammation was defined when patients with negative AF cultures and without evidence of microbial footprints had intra-amniotic inflammation (AF interleukin-6 ≥ 2.6 ng/mL). Results 1) The frequency of sterile intra-amniotic inflammation was significantly greater than that of microbial-associated intra-amniotic inflammation [26% (35/135) vs. 11% (15/135); (p=0.005)]; 2) patients with sterile intra-amniotic inflammation delivered at comparable gestational ages, had similar rates of acute placental inflammation and adverse neonatal outcomes as patients with microbial-associated intra-amniotic inflammation; and 3) patients with sterile intra-amniotic inflammation and high AF concentrations of HMGB1 (≥ 8.55 ng/mL) delivered earlier than those with low AF concentrations of HMGB1 (p=0.02). Conclusions 1) sterile intra-amniotic inflammation is more frequent than microbial-associated intra-amniotic inflammation; and 2) we propose that danger signals participate in sterile intra-amniotic inflammation in the setting of preterm labor. PMID:25078709

  4. Effect of fermentation and sterilization on anthocyanins in blueberry.

    PubMed

    Nie, Qixing; Feng, Lei; Hu, Jielun; Wang, Sunan; Chen, Haihong; Huang, Xiaojun; Nie, Shaoping; Xiong, Tao; Xie, Mingyong

    2017-03-01

    Blueberry products have various health benefits due to their high content of dietary anthocyanins. The aim of this study was to investigate the impact of fermentation and sterilization on total anthocyanin content, composition and some quality attributes of blueberry puree. The blueberry puree used here was fermented for 40 h at 37 °C by Lactobacillus after sterilization. The method of ultra-performance liquid chromatography-mass spectrometry was optimized for the rapid analysis of anthocyanins. Quality attributes including pH, color, total soluble solids and viscosity were measured. A total of 21 anthocyanins and five anthocyanidins were quantified by ultra-performance liquid chromatography. Fermented blueberry had reduced total anthocyanin content (29%) and levels of individual anthocyanins compared with fresh blueberry. Total anthocyanin content was decreased 46% by sterilization, and different degradation behavior of individual anthocyanin was appeared between fermented and sterilized-fermented blueberry puree. Fermentation and sterilization decreased the total soluble solids and pH and changed color parameters, while minimally influencing viscosity. The loss of total anthocyanin content by fermentation was related to the unstable structure of blueberry anthocyanins. Anthocyanins are sensitive to temperature (>80 °C), and degradation of anthocyanins by sterilization in blueberry should be considered in the fermentation procedure. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  5. Development and characterization of transgenic dominant male sterile rice toward an outcross-based breeding system.

    PubMed

    Abe, Kiyomi; Oshima, Masao; Akasaka, Maiko; Konagaya, Ken-Ichi; Nanasato, Yoshihiko; Okuzaki, Ayako; Taniguchi, Yojiro; Tanaka, Junichi; Tabei, Yutaka

    2018-03-01

    Genomic selection is attracting attention in the field of crop breeding. To apply genomic selection effectively for autogamous (self-pollinating) crops, an efficient outcross system is desired. Since dominant male sterility is a powerful tool for easy and successive outcross of autogamous crops, we developed transgenic dominant male sterile rice ( Oryza sativa L.) using the barnase gene that is expressed by the tapetum-specific promoter BoA9 . Barnase -induced male sterile rice No. 10 (BMS10) was selected for its stable male sterility and normal growth characteristics. The BMS10 flowering habits, including heading date, flowering date, and daily flowering time of BMS10 tended to be delayed compared to wild type. When BMS10 and wild type were placed side-by-side and crossed under an open-pollinating condition, the seed-setting rate was <1.5%. When the clipping method was used to avoid the influence of late flowering habits, the seed-setting rate of BMS10 increased to a maximum of 86.4%. Although flowering synchronicity should be improved to increase the seed-setting rate, our results showed that this system can produce stable transgenic male sterility with normal female fertility in rice. The transgenic male sterile rice would promote a genomic selection-based breeding system in rice.

  6. Sterile flowers increase pollinator attraction and promote female success in the Mediterranean herb Leopoldia comosa

    PubMed Central

    Morales, Carolina L.; Traveset, Anna; Harder, Lawrence D.

    2013-01-01

    Background and Aims Large floral displays have opposing consequences for animal-pollinated angiosperms: they attract more pollinators but also enable elevated among-flower self-pollination (geitonogamy). The presence of sterile flowers as pollinator signals may enhance attraction while allowing displays of fewer open fertile flowers, limiting geitonogamy. The simultaneous contributions of fertile and non-fertile display components to pollinator attraction and reproductive output remain undetermined. Methods The simultaneous effects of the presence of sterile flowers and fertile-flower display size in two populations of Leopoldia comosa were experimentally assessed. Pollinator behaviour, pollen removal and deposition, and fruit and seed production were compared between intact plants and plants with sterile flowers removed. Key Results The presence of sterile flowers almost tripled pollinator attraction, supplementing the positive effect of the number of fertile flowers on the number of bees approaching inflorescences. Although attracted bees visited more flowers on larger inflorescences, the number visited did not additionally depend on the presence of sterile flowers. The presence of sterile flowers improved all aspects of plant performance, the magnitude of plant benefit being context dependent. During weather favourable to pollinators, the presence of sterile flowers increased pollen deposition on stigmas of young flowers, but this difference was not evident in older flowers, probably because of autonomous self-pollination in poorly visited flowers. Total pollen receipt per stigma decreased with increasing fertile display size. In the population with more pollinators, the presence of sterile flowers increased fruit number but not seed set or mass, whereas in the other population sterile flowers enhanced seeds per fruit, but not fruit production. These contrasts are consistent with dissimilar cross-pollination and autonomous self-pollination, coupled with the strong predispersal inbreeding depression exhibited by L. comosa populations. Conclusions Sterile flowers enrich pollination quality by promoting pollen export and import, while limiting the mating costs of geitonogamy associated with large fertile displays. PMID:23131298

  7. Construction of a multicontrol sterility system for a maize male-sterile line and hybrid seed production based on the ZmMs7 gene encoding a PHD-finger transcription factor.

    PubMed

    Zhang, Danfeng; Wu, Suowei; An, Xueli; Xie, Ke; Dong, Zhenying; Zhou, Yan; Xu, Liwen; Fang, Wen; Liu, Shensi; Liu, Shuangshuang; Zhu, Taotao; Li, Jinping; Rao, Liqun; Zhao, Jiuran; Wan, Xiangyuan

    2018-02-01

    Although hundreds of genetic male sterility (GMS) mutants have been identified in maize, few are commercially used due to a lack of effective methods to produce large quantities of pure male-sterile seeds. Here, we develop a multicontrol sterility (MCS) system based on the maize male sterility 7 (ms7) mutant and its wild-type Zea mays Male sterility 7 (ZmMs7) gene via a transgenic strategy, leading to the utilization of GMS in hybrid seed production. ZmMs7 is isolated by a map-based cloning approach and encodes a PHD-finger transcription factor orthologous to rice PTC1 and Arabidopsis MS1. The MCS transgenic maintainer lines are developed based on the ms7-6007 mutant transformed with MCS constructs containing the (i) ZmMs7 gene to restore fertility, (ii) α-amylase gene ZmAA and/or (iii) DNA adenine methylase gene Dam to devitalize transgenic pollen, (iv) red fluorescence protein gene DsRed2 or mCherry to mark transgenic seeds and (v) herbicide-resistant gene Bar for transgenic seed selection. Self-pollination of the MCS transgenic maintainer line produces transgenic red fluorescent seeds and nontransgenic normal colour seeds at a 1:1 ratio. Among them, all the fluorescent seeds are male fertile, but the seeds with a normal colour are male sterile. Cross-pollination of the transgenic plants to male-sterile plants propagates male-sterile seeds with high purity. Moreover, the transgene transmission rate through pollen of transgenic plants harbouring two pollen-disrupted genes is lower than that containing one pollen-disrupted gene. The MCS system has great potential to enhance the efficiency of maize male-sterile line propagation and commercial hybrid seed production. © 2017 The Authors. Plant Biotechnology Journal published by Society for Experimental Biology and The Association of Applied Biologists and John Wiley & Sons Ltd.

  8. Lack of insurance and parity influence choice between long-acting reversible contraception and sterilization in women postpregnancy.

    PubMed

    Baldwin, Maureen K; Rodriguez, Maria I; Edelman, Alison B

    2012-07-01

    Disparities in postpregnancy contraception utilization exist, with low-income women disproportionately undergoing sterilization. We assessed the impact of increased intrauterine device (IUD) availability on rates of female sterilization. Hospital billing records were used to identify women with an IUD placement or sterilization within 1 year of a pregnancy at a university hospital between Oct 2005 and Jun 2007. Demographic data were compared between women receiving either an IUD or sterilization. There were 365 sterilizations and 223 IUD placements during the study period. IUD placements doubled over the study period from 6% to 12% of all deliveries, while sterilizations remained stable at 11% (p<.001). Demographic variables were examined for women with either public or private insurance who had financial access to both sterilization (n=253) and IUD (n=223). Women receiving sterilization were slightly older (mean age 31 years versus 30 years, p=.03), of higher parity (median three versus two, p<.01), more likely to have had cesarean delivery (69% versus 31%, p<.001) and more likely to have public insurance (77% versus 23%, p<.001) than women who received IUD. Approximately 45% of women delivering in Oregon in 2007 were publicly insured (2010 Maternal and Child Health Update: States Make Progress Towards Improving Systems of Care. National Governor's Association, Table 6. Available at http://www.nga.org/files/live/sites/NGA/files/pdf/MCHUPDATE2010.PDF, accessed Nov 2011). After adjusting for age, parity and type of delivery, women choosing sterilization were more likely to have public insurance than women choosing IUD (odds ratio 8.4, 95% confidence interval 4.7-14.9, p<.0001). Women choosing sterilization are more likely to have public insurance than women choosing IUD and may represent a continued trend toward nonreversible contraception among women of lower socioeconomic status despite available long-acting reversible methods. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Proteomic analysis reveals strong mitochondrial involvement in cytoplasmic male sterility of pepper (Capsicum annuum L.).

    PubMed

    Guo, Jinju; Wang, Peng; Cheng, Qing; Sun, Limin; Wang, Hongyu; Wang, Yutong; Kao, Lina; Li, Yanan; Qiu, Tuoyu; Yang, Wencai; Shen, Huolin

    2017-09-25

    Although cytoplasmic male sterility (CMS) is widely used for developing pepper hybrids, its molecular mechanism remains unclear. In this study, we used a high-throughput proteomics method called label-free to compare protein abundance across a pepper CMS line (A-line) and its isogenic maintainer line (B-line). Data are available via ProteomeXchange with identifier PXD006104. Approximately 324 differentially abundant protein species were identified and quantified; among which, 47 were up-accumulated and 140 were down-accumulated in the A-line; additionally, 75 and 62 protein species were specifically accumulated in the A-line and B-line, respectively. Protein species involved in pollen exine formation, pyruvate metabolic processes, the tricarboxylic acid cycle, the mitochondrial electron transport chain, and oxidative stress response were observed to be differentially accumulated between A-line and B-line, suggesting their potential roles in the regulation of pepper pollen abortion. Based on our data, we proposed a potential regulatory network for pepper CMS that unifies these processes. Artificial emasculation is a major obstacle in pepper hybrid breeding for its high labor cost and poor seed purity. While the use of cytoplasmic male sterility (CMS) in hybrid system is seriously frustrated because a long time is needed to cultivate male sterility line and its isogenic restore line. Transgenic technology is an effective and rapid method to obtain male sterility lines and its widely application has very important significance in speeding up breeding process in pepper. Although numerous studies have been conducted to select the genes related to male sterility, the molecular mechanism of cytoplasmic male sterility in pepper remains unknown. In this study, we used the high-throughput proteomic method called "label-free", coupled with liquid chromatography-quadrupole mass spectrometry (LC-MS/MS), to perform a novel comparison of expression profiles in a CMS pepper line and its maintainer line. Based on our results, we proposed a potential regulated protein network involved in pollen development as a novel mechanism of pepper CMS. Copyright © 2017. Published by Elsevier B.V.

  10. High-pressure destruction kinetics of Clostridium sporogenes spores in ground beef at elevated temperatures.

    PubMed

    Zhu, Songming; Naim, Fadia; Marcotte, Michèle; Ramaswamy, Hosahalli; Shao, Yanwen

    2008-08-15

    High pressure (HP) is an alternative technique for thermal sterilization of foods with minimum quality loss. HP destruction kinetics of bacterial spores is essential to establishing sterilization process, but knowledge in this field is still very limited. In this study, destruction kinetics was investigated using Clostridium sporogenes PA 3679 (ATCC7955) spores in extra-lean ground beef (5 g each sealed in a sterile plastic bag). Duplicated samples were subjected to HP treatments at 700, 800 and 900 MPa in a HP system equipped with a Polyoxymethylene insulator to maintain constant temperatures at 80, 90 and 100 degrees C during pressure-holding time. The kinetic parameters of the spores (D- and Z-values) were evaluated at these pressures and temperatures. For the pressure from 700 to 900 MPa, D-values ranged from 15.8 to 7.0 and 1.5 to 0.63 min at 80 and 100 degrees C, respectively. The pressure resistance of Z(T)(P) value was 520-563 MPa at 80-100 degrees C. The temperature resistance of Z(P)(T) value was 19.1-19.7 degrees C at 700-900 MPa, much higher than that at atmospheric condition (12.4 degrees C). A regression model was generated which can be used to predict D-value or the death time of a minimum process under given pressure and temperature conditions. HP treatment with elevated temperatures can destroy bacterial spores with a shorter time or lower temperature than conventional thermal processing. This study provides useful information for the achievement of a safe HP sterilization process.

  11. Material and method for promoting the growth of anaerobic bacteria

    DOEpatents

    Adler, H.I.

    1984-10-09

    A material and method is disclosed for promoting the growth of anaerobic bacteria which includes a nutrient media containing a hydrogen donor and sterile membrane fragments of bacteria having an electron transfer system which reduces oxygen to water. Dissolved oxygen in the medium is removed by adding the sterile membrane fragments to the nutrient medium and holding the medium at a temperature of about 10 to about 60 C until the dissolved oxygen is removed. No Drawings

  12. Material and method for promoting the growth of anaerobic bacteria

    DOEpatents

    Adler, Howard I.

    1984-01-01

    A material and method for promoting the growth of anaerobic bacteria which includes a nutrient media containing a hydrogen donor and sterile membrane fragments of bacteria having an electron transfer system which reduces oxygen to water. Dissolved oxygen in the medium is removed by adding the sterile membrane fragments to the nutrient medium and holding the medium at a temperature of about 10.degree. to about 60.degree. C. until the dissolved oxygen is removed.

  13. Effect of Repeated Sterilization Cycles on the Physical Properties of Scaling Instruments: A Scanning Electron Microscopy Study

    PubMed Central

    Porto, Alessandra Nogueira; Borges, Álvaro Henrique; Semenoff-Segundo, Alex; Raslan, Suzane A; Pedro, Fábio Luis Miranda; Jorge, Antônio Olavo Cardoso; Bandeca, Matheus Coelho

    2015-01-01

    Background: Repeated sterilizations cycles cause undesirable alterations in the material properties of the instruments, such as corrosion, alterations in the hardness of the metal and the loss of the cutting sharpness of the instrument. This research examined the effect of repeated dry heat sterilization and autoclaves cycles on carbon steel (CS) and stainless steel (SS) curettes during the scaling and root planning. Materials and Methods: A total of 77 Gracey curettes were used in this study. Of these, 35 were SS and 42 were CS curettes submitted in different process: Dry heat, autoclave, inhibition of corrosion and autoclave, scaling, root planning and dry heat, scaling, root planning, inhibition of corrosion and autoclave. The inhibition of corrosion used on the carbon curettes (prior to sterilization in the autoclave) was sodium nitrite at 2%. The curettes received 10 consecutive cycles of sterilization and after that the cutting edges were examined in the electronic microscope, at 60 and 100 magnification times. Results: The images were evaluated by three independent examiners, who compared the photographs of each group with the control group. Conclusion: The surface corrosion products and a deterioration of the edges were observed and the results showed that the SS curettes suffered little alteration with sterilization, scaling, root planning whereas the CS curettes were visibly affected by sterilization in the autoclave, but when the inhibition of corrosion was used prior to the sterilization, the oxidation was considerably reduced. PMID:26028893

  14. Nanoparticles as potential new generation broad spectrum antimicrobial agents.

    PubMed

    Yah, Clarence S; Simate, Geoffrey S

    2015-09-02

    The rapid emergence of antimicrobial resistant strains to conventional antimicrobial agents has complicated and prolonged infection treatment and increased mortality risk globally. Furthermore, some of the conventional antimicrobial agents are unable to cross certain cell membranes thus, restricting treatment of intracellular pathogens. Therefore, the disease-causing-organisms tend to persist in these cells. However, the emergence of nanoparticle (NP) technology has come with the promising broad spectrum NP-antimicrobial agents due to their vast physiochemical and functionalization properties. In fact, NP-antimicrobial agents are able to unlock the restrictions experienced by conventional antimicrobial agents. This review discusses the status quo of NP-antimicrobial agents as potent broad spectrum antimicrobial agents, sterilization and wound healing agents, and sustained inhibitors of intracellular pathogens. Indeed, the perspective of developing potent NP-antimicrobial agents that carry multiple-functionality will revolutionize clinical medicine and play a significant role in alleviating disease burden.

  15. Attitudes on the Population Crisis at a Small Liberal-Arts College

    ERIC Educational Resources Information Center

    Jenkins, John B.; Mitchell, Robert C.

    1973-01-01

    A survey of attitudes of college students indicated they desired few children, were more receptive to sterilization, and had a general ignorance about methods of birth control and possible side effects of sterilization. These results are in contradiction with another, similar study. Replication of the study is suggested. (PS)

  16. Microwave powered sterile access port

    NASA Technical Reports Server (NTRS)

    Sauer, Richard L. (Inventor); Atwater, James E. (Inventor); Dahl, Roger W. (Inventor); Garmon, Frank C. (Inventor); Lunsford, Teddie D. (Inventor); Michalek, William F. (Inventor); Wheeler, Jr., Richard R. (Inventor)

    2000-01-01

    A device and method for elimination of contamination during transfer of materials either into or from bioreactors, food containers, or other microbially vulnerable systems. Using microwave power, thermal sterilizations of mating fixtures are achieved simply, reliably, and quickly by the volatilization of small quantities of water to produce superheated steam which contacts all exposed surfaces.

  17. Stability of aspartame and neotame in pasteurized and in-bottle sterilized flavoured milk.

    PubMed

    Kumari, Anuradha; Choudhary, Sonika; Arora, Sumit; Sharma, Vivek

    2016-04-01

    Analytical high performance liquid chromatography (HPLC) conditions were standardized along with the isolation procedure for separation of aspartame and neotame in flavoured milk (pasteurized and in-bottle sterilized flavoured milk). The recovery of the method was approximately 98% for both aspartame and neotame. The proposed HPLC method can be successfully used for the routine determination of aspartame and neotame in flavoured milk. Pasteurization (90 °C/20 min) resulted in approximately 40% loss of aspartame and only 8% of neotame was degraded. On storage (4-7°C/7 days) aspartame and neotame content decreased significantly (P<0.05) from 59.70% to 44.61% and 91.78% to 87.18%, respectively. Sterilization (121 °C/15 min) resulted in complete degradation of aspartame; however, 50.50% of neotame remained intact. During storage (30 °C/60 days) neotame content decreased significantly (P<0.05) from 50.36% to 8.67%. Results indicated that neotame exhibited better stability than aspartame in both pasteurized and in-bottle sterilized flavoured milk. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Evaluation and quantification of reprocessing modification in single-use devices in interventional cardiology

    NASA Astrophysics Data System (ADS)

    Tessarolo, Francesco; Ferrari, Paolo; Silvia, Bortoluzzi; Motta, Antonella; Migliaresi, Claudio; Zennaro, Lucio; Rigo, Adelio; Guarrera, Giovanni Maria; Nollo, Giandomenico

    2004-11-01

    The increasing demand in interventional cardiology urges for reprocessing of single-use-labelled medical devices. To fulfil this aim, accurate and validated regeneration protocols are mandatory to guarantee sterility, functionality and safeness. The reprocessing protocol was realized by decontamination with chloro-donors, cleaning with enzymatic solutions and hydrogen peroxide gas plasma sterilization. Reprocessing effects on ablation and electrophysiology catheters were evaluated by assessing physical-chemical changes on surfaces and bulks, as a function of the reprocessing cycles number. Conventional optical microscopy and environmental scanning electron microscopy (ESEM) underlined the presence of micro-scratches on the polyurethane shaft surface. A clear correlation was found between surface damages and number of reprocessing cycles. Atomic force microscopy (AFM) confirmed the occurrence of physical-chemical etching of the polyurethane shaft caused by the hydrogen peroxide plasma sterilization, with increasing of nano-roughness at increasing number of the reprocessing cycles. UV-Vis spectra performed on the incubation solution of polymeric shaft sample, showed an absorbance increase at about 208 nm. This fact could be attributed to the water elution from the polymer of low molecular weight oligomers. The presence of hydrolysis products of the polymeric shaft after incubation demands both the characterization of the products released in the solution and the chemical characterization of the water exposed surface.

  19. Preliminary thermoluminescence and optically stimulated luminescence investigation of commercial pharmaceutical preparations towards the drug sterilization dosimetry.

    PubMed

    Kazakis, Nikolaos A; Tsirliganis, Nestor C; Kitis, George

    2014-09-01

    Drug sterilization with ionizing radiation is a well-established technology and is gaining ground the last decades due to its numerous advantages. Identification of irradiated drugs would be interesting and, in this respect, the present work aims, for the first time to the authors' best knowledge, to explore whether OSL and TL can be employed as methods for post-sterilization dosimetry on commercial drugs, i.e., as tools for the detection of irradiated drugs. Five widely used drugs, i.e., Daktarin(®), Aspirin(®), Panadol(®), Brufen(®) and Procef(®), are used for this purpose. Preliminary findings are very promising towards the post-sterilization dosimetry and the use of commercial drugs for normal and/or accidental dosimetry. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Accuracy Considerations in Sterile Compounding.

    PubMed

    Akers, Michael J

    2017-01-01

    Published information about the accuracy of filling and closing operations of sterile products is limited and guidelines on the topic are very general. This article highlights the basic principles in sterile-product filling of syringes and vials. Also covered in this article are descriptions of some of the available devices for filling containers, a brief discussion of the advances in vial and syringe filling, a discussion on the advantages and disadvantages of sterile product filling methods, and a discussion on possible problems encountered during filling operations. Because of the extremely high costs of some new drugs, especially biopharmaceuticals, compounding pharmacies may prefer to fill small batches to reduce the risk of unacceptable monetary losses in the event of a manufacturing deviation that results in batch rejection. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  1. Astrophysical constraints on resonantly produced sterile neutrino dark matter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schneider, Aurel, E-mail: aurel@physik.uzh.ch

    2016-04-01

    Resonantly produced sterile neutrinos are considered an attractive dark matter (DM) candidate only requiring a minimal, well motivated extension to the standard model of particle physics. With a particle mass restricted to the keV range, sterile neutrinos are furthermore a prime candidate for warm DM, characterised by suppressed matter perturbations at the smallest observable scales. In this paper we take a critical look at the validity of the resonant scenario in the context of constraints from structure formation. We compare predicted and observed number of Milky-Way satellites and we introduce a new method to generalise existing Lyman-α limits based onmore » thermal relic warm DM to the case of resonant sterile neutrino DM . The tightest limits come from the Lyman-α analysis, excluding the entire parameter space (at 2-σ confidence level) still allowed by X-ray observations. Constraints from Milky-Way satellite counts are less stringent, leaving room for resonant sterile neutrino DM most notably around the suggested line signal at 7.1 keV.« less

  2. [Preliminary Study of Lonicera hypoglauca on Germination Conditions of Sand Culture Seeds and Sterilization Method of Sand Culture Seedling Sterilization].

    PubMed

    Tan, Mu-xiu; Zeng, Wen-wen; Wei, Peng-xiao; Mo, Qiao-cheng; Pu, Zu-ning; Cen, Xiu-fen; Shi, Feng-hua

    2015-05-01

    To explore the germination conditions of Lonicera hypoglauca sand culture seeds and the effects of sand culture seedlings sterilization. 0.1% HgCl2 with different sterilization time, different illumination time and temperature culture condition were adopted to study the germination conditions of sand culture seeds. Different sterilization treatments and different hardening-seedling days were used to test the sterilization effect of sand culture seedlings. The sterilization effect of the combination of 75% ethanol 30 s + 0.1% HgCl2 5 min on Lonicera hypoglauca seeds was the optimum,with the average pollution rate of 15.56%, and the average germination rate reached 51.11%. The combination of varied temperature-room temperature under light for 12 h/d was the best, with the average germination rate peaked at 75.49%, and the average germination potential reached 68.36%. The treatment of detergent liquor scrub-tap water wash on the part above the hypocotyl, which was sand cultured under the opening condition and had no root, showed the best sterilization effect, with the average pollution rate was zero, and the average survival rate peaked at 100.00%. The sterilization effect of sand culture seedlings, which was disinfected after cleaning by detergent liquor scrub-tap water wash after hardening-seeding for 30 days, was the best, with the average pollution rate of 50.00%, and the average survival rate of 100.00%. The best sterilization effect is the combination of 75% ethanol 30 s + 0.1% HgCl2 5 min; Lighting for 12 h/d of varied temperature-room temperature is regarded as the optimum culture condition. The treatment of detergent liquor scrub-tap water wash treatment on the part above the hypocotyl,which is sand cultured under the opening condition and had no root, shows the best sterilization effect. For the sand culture seedlings, before inoculated in subculture medium, should be hardening-seedling for some days and sterilized after detergent liquor scrub-tap water wash.

  3. A randomized, controlled, multicenter contraceptive efficacy clinical trial of the intravas device, a nonocclusive surgical male sterilization.

    PubMed

    Lu, Wen-Hong; Liang, Xiao-Wei; Gu, Yi-Qun; Wu, Wei-Xiong; Bo, Li-Wei; Zheng, Tian-Gui; Chen, Zhen-Wen

    2014-01-01

    Because of unavoidable complications of vasectomy, this study was undertaken to assess the efficacy and safety of male sterilization with a nonobstructive intravas device (IVD) implanted into the vas lumen by a mini-surgical method compared with no-scalpel vasectomy (NSV). IVDs were categorized into two types: IVD-B has a tail used for fixing to the vas deferens (fixed wing) whereas IVD-A does not. A multicenter prospective randomized controlled clinical trial was conducted in China. The study was comprised of 1459 male volunteers seeking vasectomy who were randomly assigned to the IVD-A (n = 487), IVD-B (n = 485) or NSV (n = 487) groups and underwent operation. Follow-up included visits at the 3 rd -6 th and 12 th postoperative months. The assessments of the subjects involved regular physical examinations (including general and andrological examinations) and semen analysis. The subjects' partners also underwent monitoring for pregnancy by monthly interviews regarding menstruation and if necessary, urine tests. There were no significant differences in pregnancy rates (0.65% for IVD-A, 0 for IVD-B and 0.21% for NSV) among the three groups (P > 0.05). The cumulative rates of complications at the 12 th postoperative month were zero, 0.9% and 1.7% in the three groups, respectively. In conclusion, IVD male sterilization exhibits a low risk of long-term adverse events and was found to be effective as a male sterilization method, similar to the NSV technique. IVD male sterilization is expected to be a novel contraceptive method.

  4. Searches for sterile neutrinos with NOvA

    DOE PAGES

    Davies, Gavin S.; Aurisano, Adam; Kafka, Gareth K.; ...

    2016-11-15

    Contradictory evidence has been presented on the issue of neutrino mixing between the three known active neutrinos and light sterile neutrino species. Apparent short-baseline neutrino oscillations observed by the LSND and MiniBooNE experiments, the collective evidence of the reactor neutrino anomaly, and the gallium anomaly all point towards sterile neutrinos with mass at the 1 eV level. While these results are tantalizing, they are not conclusive as they are in tension with null results from other short-baseline experiments, and with disappearance searches in longbaseline and atmospheric experiments. The NOvA (NuMI Off-Axis v e Appearance) experiment may help clarify the situationmore » by searching for disappearance of active neutrinos from the NuMI (Neutrinos from the Main Injector) beam over a baseline of 810 km. We describe the method used by NOvA to look for oscillations into sterile neutrinos at the Far Detector (FD) through the disappearance of neutral-current (NC) neutrino events, including preliminary results of this search. In addition, the Near Detector (ND) is well suited for searching for anomalous short-baseline oscillations and probing the LSND and MiniBooNE sterile neutrino allowed regions using a variety of final states. We also present a novel method for selecting samples with high purity at the ND using convolutional neural networks. Furthermore, based on this method, the sensitivity to anomalous short-baseline nt appearance are shown, and searches for anomalous v e appearance and v μ disappearance at the NOvA ND are presented.« less

  5. Characterizing Effects of Nitric Oxide Sterilization on tert-Butyl Acrylate Shape Memory Polymers

    NASA Astrophysics Data System (ADS)

    Phillippi, Ben

    As research into the potential uses of shape memory polymers (SMPs) as implantable medical devices continues to grow and expand, so does the need for an accurate and reliable sterilization mechanism. The ability of an SMP to precisely undergo a programmed shape change will define its ability to accomplish a therapeutic task. To ensure proper execution of the in vivo shape change, the sterilization process must not negatively affect the shape memory behavior of the material. To address this need, this thesis investigates the effectiveness of a benchtop nitric oxide (NOx) sterilization process and the extent to which the process affects the shape memory behavior of a well-studied tert-Butyl Acrylate (tBA) SMP. Quantifying the effects on shape memory behavior was performed using a two-tiered analysis. A two-tiered study design was used to determine if the sterilization process induced any premature shape recovery and to identify any effects that NOx has on the overall shape memory behavior of the foams. Determining the effectiveness of the NOx system--specially, whether the treated samples are more sterile/less contaminated than untreated--was also performed with a two-tiered analysis. In this case, the two-tiered analysis was employed to have a secondary check for contamination. To elaborate, all of the samples that were deemed not contaminated from the initial test were put through a second sterility test to check for contamination a second time. The results of these tests indicated the NOx system is an effective sterilization mechanism and the current protocol does not negatively impact the shape memory behavior of the tBA SMP. The samples held their compressed shape throughout the entirety of the sterilization process. Additionally, there were no observable impacts on the shape memory behavior induced by NOx. Lastly, the treated samples demonstrated lower contamination than the untreated. This thesis demonstrates the effectiveness of NOx as a laboratory scale sterilization mechanism for heat triggered shape memory polymers. The shape memory analysis indicated that the magnitude of the length changes induced by NOx is small enough that it does not make a statistically significant impact on the shape memory behavior of the foams. Additionally, there were no observable effects on the shape memory behavior induced by NOx. The results further indicated the NOx system is effective at sterilizing porous scaffolds, as none of the sterilized samples showed contamination. Testing methods proved to be effective because the initial sterility test was able to identify all of the contaminated samples and preliminary results indicated that NOx sterilization improves the sterility of the foams.

  6. Disinfection/sterilization of extracted teeth for dental student use.

    PubMed

    Dominici, J T; Eleazer, P D; Clark, S J; Staat, R H; Scheetz, J P

    2001-11-01

    Extracted human teeth are used in many preclinical courses. While there has been no report of disease transmission with extracted teeth, sterilization of teeth used in the teaching laboratory should be a concern. The purpose of this study was to determine the effectiveness of different sterilization/disinfection methods of extracted human teeth using Bacillus stearothermophilus, a bacteria resistant to heat and frequently used to test sterilizers. In this study, 110 extracted molars with no carious lesions were collected and stored in buffered saline. An endodontic occlusal access preparation was cut into the pulp chamber of each tooth. Pulp tissue in the chamber was removed with a broach. Approximately 1 x 10(5) B. stearothermophilus endospores in culture medium were injected into the pulp chamber, sealed with Cavit G, and then placed in sterile saline for twelve hours. Ten teeth were placed into each of eleven groups. Seven groups were immersed for one week in one of the following solutions: a) sterile saline (control group), b) 5.25% NaOCl, c) 2.6% NaOCl, d) 1% NaOCl, e) 10% buffered formalin, f) 2% gluteraldehyde, g) 0.28% quaternary ammonium. Four additional groups were treated by h) 10% formalin for two days, i) 10% formalin for four days, j) autoclaving at 240 degrees F and 20 psi for twenty minutes, and k) autoclaving at 240 degrees F and twenty psi for forty minutes. Each tooth was then aseptically split and placed in an individual test tube with growth medium. Samples were examined for evidence of growth (turbidity) at forty-eight hours. Only autoclaving for forty minutes at 240 degrees F and 20 psi or soaking in 10 percent formalin for one week were 100 percent effective in preventing growth. A chi-square analysis of the data indicates these two methods were significantly better than all other methods (p<0.001).

  7. Development of a new water sterilization device with a 365 nm UV-LED.

    PubMed

    Mori, Mirei; Hamamoto, Akiko; Takahashi, Akira; Nakano, Masayuki; Wakikawa, Noriko; Tachibana, Satoko; Ikehara, Toshitaka; Nakaya, Yutaka; Akutagawa, Masatake; Kinouchi, Yohsuke

    2007-12-01

    Ultraviolet (UV) irradiation is an effective disinfection method. In sterilization equipment, a low-pressure mercury lamp emitting an effective germicidal UVC (254 nm) is used as the light source. However, the lamp, which contains mercury, must be disposed of at the end of its lifetime or following damage due to physical shock or vibration. We investigated the suitability of an ultraviolet light-emitting diode at an output wavelength of 365 nm (UVA-LED) as a sterilization device, comparing with the other wavelength irradiation such as 254 nm (a low-pressure mercury lam) and 405 nm (LED). We used a commercially available UVA-LED that emitted light at the shortest wavelength and at the highest output energy. The new sterilization system using the UVA-LED was able to inactivate bacteria, such as Escherichia coli DH5 alpha, Enteropathogenic E. coli, Vibrio parahaemolyticus, Staphylococcus aureus, and Salmonella enterica serovar Enteritidis. The inactivations of the bacteria were dependent on the accumulation of UVA irradiation. Taking advantage of the safety and compact size of LED devices, we expect that the UVA-LED sterilization device can be developed as a new type of water sterilization device.

  8. Which is the best method of sterilization for recycled bone autograft in limb salvage surgery: a radiological, biomechanical and histopathological study in rabbit.

    PubMed

    Yasin, Nor Faissal; Ajit Singh, Vivek; Saad, Marniza; Omar, Effat

    2015-04-15

    Limb salvage surgery is a treatment of choice for sarcomas of the extremities. One of the options in skeletal reconstruction after tumour resection is by using a recycled bone autograft. The present accepted methods of recycling bone autografts include autoclaving, pasteurization and irradiation. At the moment there is lack of studies that compare the effectiveness of various sterilization methods used for recycling bone autografts and their effects in terms of bone incorporation. This study was performed to determine the effects of different methods of sterilization on bone autografts in rabbit by radiological, biomechanical and histopathological evaluations. Fresh rabbit cortical bone is harvested from the tibial diaphysis and sterilized extracorporeally by pasteurization (n = 6), autoclaving (n = 6), irradiation (n = 6) and normal saline as control group (n = 6). The cortical bones were immediately reimplanted after the sterilization process. The subsequent process of graft incorporation was examined over a period of 12 weeks by serial radiographs, biomechanical and histopathological evaluations. Statistical analysis (ANOVA) was performed on these results. Significance level (α) and power (β) were set to 0.05 and 0.90, respectively. Radiographic analysis showed that irradiation group has higher score in bony union compared to other sterilization groups (p = 0.041). ANOVA analysis of 'failure stress', 'modulus' and 'strain to failure' demonstrated no significant differences (p = 0.389) between treated and untreated specimens under mechanical loading. In macroscopic histopathological analysis, the irradiated group has the highest percentage of bony union (91.7 percent). However in microscopic analysis of union, the pasteurization group has significantly higher score (p = 0.041) in callus formation, osteocytes percentage and bone marrow cellularity at the end of the study indicating good union potential. This experimental study shown that both irradiation and pasteurization techniques have more favourable outcome in terms of bony union based on radiographic and histopathological evaluations. Autoclaving has the worst outcome. These results indicate that extracorporeal irradiation or pasteurization of bone autografts, are viable option for recycling bone autografts. However, pasteurization has the best overall outcomes because of its osteocytes preservation and bone marrow cellularity.

  9. Marital Status and Female and Male Contraceptive Sterilization in the United States

    PubMed Central

    Eeckhaut, Mieke Carine Wim

    2015-01-01

    Objective To examine female and male sterilization patterns in the United States based on marital status, and to determine if sociodemographic characteristics explain these sterilization patterns. Design Survival analysis of cross-sectional data from the female and male samples of the 2006–2010 National Survey of Family Growth (NSFG). Setting A trained female interviewer conducted in-home interviews. Patient(s) The 2006–2010 NSFG is designed to be representative of the U.S. civilian non-institutionalized population ages 15–44. Intervention(s) None. Main outcome measure(s) Vasectomy and tubal sterilization. Result(s) In the United States, vasectomy is the near exclusive domain of married men. Never- and ever-married single men and never-married cohabiting men had a low relative risk of vasectomy (RRs=0.1, 0.3, and 0.0, respectively) when compared to men in first marriages. Tubal sterilization was not limited to currently married, or even to ever-married women, though it was less common among never-married single women (RR=0.2) and more common among women in higher-order marriages (RR=1.8), as compared to women in first marriages. In contrast to vasectomy, differential use of tubal sterilization by marital status was driven in large part by differences in parity. Conclusion(s) This study shows that being unmarried at sterilization—an important risk factor for post-sterilization regret—was much more common among women than men. In addition to contributing to the predominance of female versus male sterilization, this pattern highlights the importance of educating women on the permanency of sterilization, as well as an opportunity to increase reliance on long-acting reversible contraceptive methods. PMID:25881875

  10. The effects of gamma irradiation on diclofenac sodium, liposome and niosome ingredients for rheumatoid arthritis

    PubMed Central

    Turker, Selcan; Çolak, Seyda; Korkmaz, Mustafa; Kiliç, Ekrem; Özalp, Meral

    2013-01-01

    The use of gamma rays for the sterilization of pharmaceutical raw materials and dosage forms is an alternative method for sterilization. However, one of the major problems of the radiosterilization is the production of new radiolytic products during the irradiation process. Therefore, the principal problem in radiosterilization is to determine and to characterize these physical and chemical changes originating from high-energy radiation. Parenteral drug delivery systems were prepared and in vitro characterization, biodistribution and treatment studies were done in our previous studies. Drug delivery systems (liposomes, niosomes, lipogelosomes and niogelosomes) encapsulating diclofenac sodium (DFNa) were prepared for the treatment of rheumatoid arthritis (RA). This work complies information about the studies developed in order to find out if gamma radiation could be applied as a sterilization method to DFNa, and the raw materials as dimyristoyl phosphatidylcholine (DMPC), surfactant I [polyglyceryl-3-cethyl ether (SUR I)], dicethyl phosphate (DCP) and cholesterol (CHOL) that are used to prepare those systems. The raw materials were irradiated with different radiation doses (5, 10, 25 and 50 kGy) and physicochemical changes (organoleptic properties pH, UV and melting point), microbiological evaluation [sterility assurance level (SAL), sterility and pyrogen test] and electron spin resonance (ESR) characteristics were studied at normal (25 °C, 60% relative humidity) and accelerated (40 °C, 75% relative humidity) stability test conditions. PMID:24265902

  11. Saline as the Sole Contrast Agent for Successful MRI-guided Epidural Injections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deli, Martin, E-mail: martin.deli@web.de; Fritz, Jan, E-mail: jfritz9@jhmi.edu; Mateiescu, Serban, E-mail: mateiescu@microtherapy.de

    Purpose. To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. Methods. A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications. Results. 105 MRI-guided epidural injections (12 of 105 withmore » gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 {+-} 9 min in the gadolinium-enhanced saline solution group and 22 {+-} 8 min in the saline solution group (p = 0.75). Conclusion. Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.« less

  12. Incidence of opioid-managed pelvic pain after hysteroscopic sterilization versus laparoscopic sterilization, U.S. 2005-2012

    PubMed Central

    Conover, Mitchell M.; Howell, Jennifer O.; Wu, Jennifer M.; Kinlaw, Alan C.; Dasgupta, Nabarun; Funk, Michele Jonsson

    2015-01-01

    Objective Compare incidence of opioid-managed pelvic pain within 12-months after hysteroscopic and laparoscopic sterilization. Methods Using administrative claims, we identified women age 18-49 without recent history of childbirth who underwent hysteroscopic or laparoscopic sterilization between 2005-2012. We defined the outcome as ≥2 diagnoses for pelvic pain and ≥2 prescription fills for opioids. We calculated adjusted hazard ratios (HR) using Cox models and propensity score methods (matching and inverse-probability-of-treatment-weighting [IPTW]). Results We identified 71,875 eligible women (hysteroscopic n=26,927 [37.5%], laparoscopic n=44,948 [62.5%]). Of those, 236 (0.88%) hysteroscopic patients and 420 (0.93%) laparoscopic patients experienced the outcome (crude HR=0.97, [95%CI: 0.83, 1.14]). Adjusted analyses also yielded near-null results (matched HR=1.08 [95%CI: 0.90, 1.31]; IPTW HR=0.97 [95%CI: 0.80, 1.18]). While most sensitivity analyses generated results close to the null, hazard ratios estimated using propensity score matching ranged from 0.65 to 1.53. Conclusions Among women without recent history of childbirth, we did not find compelling evidence of a clinically meaningful increase in the incidence of pelvic pain requiring opioids during the year after hysteroscopic sterilization. However, effects observed in sensitivity analyses may merit further investigation. PMID:25832014

  13. Investigation on physicochemical properties of plasma-activated water for the application of medical device sterilization

    NASA Astrophysics Data System (ADS)

    Abuzairi, Tomy; Ramadhanty, Savira; Puspohadiningrum, Dini Fithriaty; Ratnasari, Anita; Poespawati, Nji Raden; Purnamaningsih, Retno Wigajatri

    2018-02-01

    Plasma activated water (PAW) is a new approach to bacterial inactivation while ensuring safety and maintaining the properties of the material sterilized. Reported research imply that PAW has been effective for inactivation of bacteria. In this paper, plasma treatment using atmospheric pressure plasma was demonstrated. Physicochemical properties such as pH, temperature, ORP, and nitrite concentration were assessed. The results suggest that plasma treatment causes acidification on water and generate reactive species, creating an environment suitable for killing bacteria. Therefore, plasma activated water is an assuring method for medical devices sterilization.

  14. The effects of nutrient solution sterilization on the growth and yield of hydroponically grown lettuce

    NASA Technical Reports Server (NTRS)

    Schwartzkopf, S. H.; Dudzinski, D.; Minners, R. S.

    1987-01-01

    Two methods of removing bacteria from hydroponic nutrient solution [ultraviolet (UV) radiation and submicronic filter] were evaluated for efficiency and for their effects on lettuce (Lactuca sativa L.) production. Both methods were effective in removing bacteria; but, at high intensity, the ultraviolet sterilizer significantly inhibited the production of plants grown in the treated solution. Bacterial removal by lower intensity UV or a submicronic filter seemed to promote plant growth slightly, but showed no consistent, statistically significant effect.

  15. Pulsed Nd-YAG laser in endodontics

    NASA Astrophysics Data System (ADS)

    Ragot-Roy, Brigitte; Severin, Claude; Maquin, Michel

    1994-12-01

    The purpose of this study was to establish an operative method in endodontics. The effect of a pulsed Nd:YAG laser on root canal dentin has been examined with a scanning electron microscope. Our first experimentation was to observe the impacts carried out perpendicularly to root canal surface with a 200 micrometers fiber optic in the presence of dye. Secondarily, the optical fiber was used as an endodontic instrument with black dye. The irradiation was performed after root canal preparation (15/100 file or 40/100 file) or directly into the canal. Adverse effects are observed. The results show that laser irradiation on root canal dentin surfaces induces a nonhomogeneous modified dentin layer, melted and resolidified dentin closed partially dentinal tubules. The removal of debris is not efficient enough. The laser treatment seems to be indicated only for endodontic and periapical spaces sterilization after conventional root canal preparation.

  16. Design and Analysis of a Two-Stage Adsorption Air Chiller

    NASA Astrophysics Data System (ADS)

    Benrajesh, P.; Rajan, A. John

    2017-05-01

    The objective of this article is to design and build a bio-friendly air-conditioner, by using adsorption method in the presence of 15% of calcium carbide in water. Aluminum sheet metals are used to form three identical tunnels, to pass the air for processing. Exhaust heat generated from the dairy sterilizing unit process is reutilized, for cooling the environment through this equipment. This equipment is designed, and the analysis is carried out to quantify the COP, SCP, and cooling power. Heat exchangers are designed; its Performance Parameters are quantified and correlated with the conventional designs. It is observed that the new adsorption chiller can produce the coefficient of performance of chiller as 1.068; the Specific cooling power of 10.66 (W/Kg); and the Cooling power of 4.2 KW. This equipment needs 0 to 15 minutes to reach the desired cool breeze (24°c) from the existing room temperature (29°c).

  17. Radiation sterilization of skin allograft

    NASA Astrophysics Data System (ADS)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-07-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6. The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2. The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  18. The Effect of Sterile Acellular Dermal Matrix Use on Complication Rates in Implant-Based Immediate Breast Reconstructions

    PubMed Central

    Park, Youngsoo; Choi, Kyoung Wook; Chung, Kyu-Jin; Kim, Tae Gon; Kim, Yong-Ha

    2016-01-01

    Background The use of acellular dermal matrix (ADM) in implant-based immediate breast reconstruction has been increasing. The current ADMs available for breast reconstruction are offered as aseptic or sterile. No published studies have compared aseptic and sterile ADM in implant-based immediate breast reconstruction. The authors performed a retrospective study to evaluate the outcomes of aseptic versus sterile ADM in implant-based immediate breast reconstruction. Methods Implant-based immediate breast reconstructions with ADM conducted between April 2013 and January 2016 were included. The patients were divided into 2 groups: the aseptic ADM (AlloDerm) group and the sterile ADM (MegaDerm) group. Archived records were reviewed for demographic data and postoperative complication types and frequencies. The complications included were infection, flap necrosis, capsular contracture, seroma, hematoma, and explantation for any cause. Results Twenty patients were reconstructed with aseptic ADM, and 68 patients with sterile ADM. Rates of infection (15.0% vs. 10.3%), flap necrosis (5.0% vs. 7.4%), capsular contracture (20.0% vs. 14.7%), seroma (10.0% vs. 14.7%), hematoma (0% vs. 1.5%), and explantation (10.0% vs. 8.8%) were not significantly different in the 2 groups. Conclusions Sterile ADM did not provide better results regarding infectious complications than aseptic ADM in implant-based immediate breast reconstruction. PMID:27896182

  19. Production of a sterile species: Quantum kinetics

    NASA Astrophysics Data System (ADS)

    Boyanovsky, D.; Ho, C. M.

    2007-10-01

    Production of a sterile species is studied within an effective model of active-sterile neutrino mixing in a medium in thermal equilibrium. The quantum kinetic equations for the distribution functions and coherences are obtained from two independent methods: the effective action and the quantum master equation. The decoherence time scale for active-sterile oscillations is τdec=2/Γaa, but the evolution of the distribution functions is determined by the two different time scales associated with the damping rates of the quasiparticle modes in the medium: Γ1=Γaacos⁡2θm; Γ2=Γaasin⁡2θm where Γaa is the interaction rate of the active species in the absence of mixing and θm the mixing angle in the medium. These two time scales are widely different away from Mikheyev-Smirnov-Wolfenstein resonances and preclude the kinetic description of active-sterile production in terms of a simple rate equation. We give the complete set of quantum kinetic equations for the active and sterile populations and coherences and discuss in detail the various approximations. A generalization of the active-sterile transition probability in a medium is provided via the quantum master equation. We derive explicitly the usual quantum kinetic equations in terms of the “polarization vector” and show their equivalence to those obtained from the quantum master equation and effective action.

  20. COHERENT constraints to conventional and exotic neutrino physics

    NASA Astrophysics Data System (ADS)

    Papoulias, D. K.; Kosmas, T. S.

    2018-02-01

    The process of neutral-current coherent elastic neutrino-nucleus scattering, consistent with the Standard Model (SM) expectation, has been recently measured by the COHERENT experiment at the Spallation Neutron Source. On the basis of the observed signal and our nuclear calculations for the relevant Cs and I isotopes, the extracted constraints on both conventional and exotic neutrino physics are updated. The present study concentrates on various SM extensions involving vector and tensor nonstandard interactions as well as neutrino electromagnetic properties, with an emphasis on the neutrino magnetic moment and the neutrino charge radius. Furthermore, models addressing a light sterile neutrino state and scenarios with new propagator fields—such as vector Z' and scalar bosons—are examined, and the corresponding regions excluded by the COHERENT experiment are presented.

  1. Geographic Variation in Characteristics of Postpartum Women Using Female Sterilization.

    PubMed

    White, Kari; Potter, Joseph E; Zite, Nikki

    2015-01-01

    Southern states have higher rates of female sterilization compared with other areas of the United States, and the reasons for this are not well understood. We examined whether low-income and racial/ethnic minority women, who were previous targets of coercive practices, disproportionately report using sterilization in the South. We used data from 12 states participating in the Pregnancy Risk Assessment Monitoring System that collected information on women's contraceptive method use between 2006 and 2009. We categorized states according to geographic region: South, Midwest/West, and Northeast. Within each region, we computed the percentage of women using sterilization according to their demographic and obstetric characteristics and estimated multivariable-adjusted prevalence ratios to evaluate whether the same characteristics were associated with sterilization use. The percentage of postpartum women using sterilization ranged from 5.0% to 9.9% in the Northeast, 8.9% to 10.6% in the Midwest/West, and 11.6% to 22.4% in the South. Women in nearly all subgroups in Southern states were more likely to use sterilization than women in the Northeast. After multivariable adjustment, there were no differences in the prevalence of sterilization for Blacks compared with Whites in the Northeast (0.76; 95% CI, 0.55-1.06), Midwest/West (0.91; 95% CI, 0.80-1.04), and South (0.96; 95% CI, 0.85-1.07). Women with Medicaid-paid deliveries (vs. private insurance) had a higher prevalence of sterilization in all regions (p < .05). These findings do not indicate that low-income and racial/ethnic minority women in the South use sterilization at disproportionately higher rates compared with other regions, and suggest that other differences, such as social norms and family planning policies, may contribute to this geographic variation. Copyright © 2015 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  2. Effects of different sterilization methods on the physico-chemical and bioresponsive properties of plasma-treated polycaprolactone films.

    PubMed

    Ghobeira, Rouba; Philips, Charlot; Declercq, Heidi; Cools, Pieter; De Geyter, Nathalie; Cornelissen, Ria; Morent, Rino

    2017-01-24

    For most tissue engineering applications, surface modification and sterilization of polymers are critical aspects determining the implant success. The first part of this study is thus dedicated to modifying polycaprolactone (PCL) surfaces via plasma treatment using a medium pressure dielectric barrier discharge, while the second part focuses on the sterilization of plasma-modified PCL. Chemical and physical surface changes are examined making use of water contact angle goniometry (WCA), x-ray photoelectron spectroscopy and atomic force microscopy. Bioresponsive properties are evaluated by performing cell culture tests. The results show that air and argon plasmas decrease the WCA significantly due to the incorporation of oxygen-containing functionalities onto the PCL surface, without modifying its morphology. Extended treatment times lead to PCL degradation, especially in the case of air plasma. In addition to surface modification, the plasma potential to sterilize PCL is studied with appropriate treatment times, but sterility has not been achieved so far. Therefore, plasma-modified films are subjected to UV, H 2 O 2 plasma (HP) and ethylene oxide (EtO) sterilizations. UV exposure of 3 h does not alter the PCL physico-chemical properties. A decreased wettability is observed after EtO sterilization, attributable to the modification of PCL chain ends reacting with EtO molecules. HP sterilization increases the WCA of the plasma-treated samples, presumably due to the scission of the hydrophilic bonds generated during the prior plasma treatments. Moreover, HP modifies the PCL surface morphology. For all the sterilizations, an improved cell adhesion and proliferation is observed on plasma-treated films compared to untreated ones. EtO shows the lowest proliferation rate compared to HP and UV. Overall, of the three sterilizations, UV is the most effective, since the physical alterations provoked by HP might interfere with the structural integrity when it comes to 3D scaffolds, and the chemical modifications caused by EtO, in addition to its toxicity, interfere with PCL bioactivity.

  3. Planning, evaluation and analytical studies in planetary quarantine and spacecraft sterilization

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The technical and analytical support used to aid in developing requirements for planetary quarantine are presented. The investigation was divided into 8 work tasks which are presented in tabular form. Data include methods of sterilization, safety margins for quarantine, revision of contamination logs for Mars and Venus, and estimates of encapsulated and 'free' microbial burden.

  4. Developing Sterile Insect Technique (SIT) as a tool Mosquito Control Districts can use for integrated Aedes aegypti control

    USDA-ARS?s Scientific Manuscript database

    New tools are clearly needed for integrated mosquito management of Ae. aegypti. We describe the sterile insect technique (SIT) that we are developing as a method to control Ae. aegypti by partnering with two prominent Florida mosquito control districts (MCD) and the FAO/IAEA Insect Pest Control Sub...

  5. Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization

    PubMed Central

    BULEM, Üreyen Kaya; KECECI, Ayse Diljin; GULDAS, Hilmi Egemen

    2013-01-01

    NiTi instruments have a high risk of separation due to torsional or flexural fatigue (cyclic fatigue). Chemomechanical preparation, cleaning procedures, chemical disinfection and sterilization cause the corrosion of endodontic instruments that may weaken the fracture resistance of the instruments. Objective To assess the effects of NaOCl immersion and autoclave sterilization on the cyclic fatigue resistance of ProFile, FlexMaster, Mtwo and TwistedFiles NiTi instruments (tip size 25, 0.06 taper, n=160). Material and Methods The instruments (n=10 for each subgroup) were dynamically immersed in NaOCl; immersed in NaOCl and sterilized in one autoclave cycle; 5 cycles immersed in NaOCl and sterilized in autoclave and not immersed in NaOCl and not sterilized (control group). Dynamic cyclic fatigue resistance was tested. The number of cycles to failure (NCF) were statistically analyzed (P<0.05). Results Kruskall-Wallis test indicated significant differences among the tested instruments in terms of NCF (P=0.000). The mean NCF of Mtwo (556.75) was higher than that of the Twisted File, Flexmaster and ProFile, 483.1, 376.12, 365.25, respectively. NaOCl immersion and autoclave sterilization have no effect on the NCF values of the tested instruments (P>.05). Conclusions Cyclic fatigue resistance of the tested NiTi instruments cannot be adversely affected by NaOCl immersion and autoclave sterilization. Production process (TwistedFiles) or design (Twisted Files, FlexMaster, Mtwo and ProFile) of the instruments can influence their cyclic fatigue resistance. PMID:24473715

  6. Marital status and female and male contraceptive sterilization in the United States.

    PubMed

    Eeckhaut, Mieke Carine Wim

    2015-06-01

    To examine female and male sterilization patterns in the United States based on marital status, and to determine if sociodemographic characteristics explain these patterns. Survival analysis of cross-sectional data from the female and male samples from the 2006-2010 National Survey of Family Growth. Not applicable. The survey is designed to be representative of the US civilian noninstitutionalized population, ages 15-44 years. None. Vasectomy and tubal sterilization. In the United States, vasectomy is the near-exclusive domain of married men. Never-married and ever-married single men, and never-married cohabiting men, had a low relative risk (RR) of vasectomy (RR = 0.1, 0.3, and 0.0, respectively), compared with men in first marriages. Tubal sterilization was not limited to currently married, or even to ever-married women, although it was less common among never-married single women (RR = 0.2) and more common among women in higher-order marriages (RR = 1.8), compared with women in first marriages. In contrast to vasectomy, differential use of tubal sterilization by marital status was driven in large part by differences in parity. This study shows that being unmarried at the time of sterilization--an important risk factor for poststerilization regret--was much more common among women than men. In addition to contributing to the predominance of female, vs. male, sterilization, this pattern highlights the importance of educating women on the permanency of sterilization, and the opportunity to increase reliance on long-acting reversible contraceptive methods. Copyright © 2015 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  7. Comparison of sterilization of reusable endoscopic biopsy forceps by autoclaving and ethylene oxide gas.

    PubMed

    Yoon, Jai Hoon; Yoon, Byung Chul; Lee, Hang Lak; Lee, Jun Kyu; Kim, Yong-Tae; Lee, Dong Ho; Choi, Il Ju; Lee, Don Haeng; Kim, Dong Hee

    2012-02-01

    Every country has standardized reprocessing guidelines for reducing the risk of microorganism transmission via reusable biopsy forceps. Sterilization is performed either by autoclaving or with the use of ethylene oxide (EO) gas. However, there are no clear standard global recommendations. The aim of this study was to determine whether EO gas or autoclaving is a safer and more effective method for the sterilization of reusable forceps. This was a prospective study conducted at multiple tertiary referral centers. Seventy reusable biopsy forceps that had been reused at least 20 times each were collected from six endoscopy centers. In all, 61 forceps from five centers were sterilized using EO gas, and the nine forceps from the remaining center were placed in an autoclave. We performed real-time polymerase chain reaction (RT-PCR) for Mycobacterium tuberculosis and hepatitis B virus and performed bacterial cultures on the reusable forceps, which were cut into 2- to 3-cm sections. The forceps were also scanned with an electron microscope (EM) to detect surface damage and contamination. Escherichia coli bacteria were cultured from 2 of the 61 (3.3%) reusable biopsy forceps sterilized with EO gas. On EM scanning, abundant debris and tissue materials remained on the cup surfaces of the reused biopsy forceps and on their inner wires. No microorganisms were found on the autoclaved forceps. Sterilization with EO gas may be inadequate because the complicated structure of the forceps may interfere with sterilization. Therefore, for optimum safety, reusable biopsy forceps should be sterilized by autoclaving.

  8. A microwave-powered sterilizable interface for aseptic access to bioreactors that are vulnerable to microbial contamination

    NASA Technical Reports Server (NTRS)

    Atwater, J. E.; Michalek, W. F.; Wheeler, R. R. Jr; Dahl, R.; Lunsford, T. D.; Garmon, F. C.; Sauer, R. L.

    2001-01-01

    Novel methods and apparatus that employ the rapid heating characteristics of microwave irradiation to facilitate the aseptic transfer of nutrients, products, and other materials between microbially sensitive systems and the external environment are described. The microwave-sterilizable access port (MSAP) consists of a 600-W magnetron emitting at a frequency of 2.45 GHz, a sterilization chamber with inlet and outlet flow lines, and a specimen transfer interface. Energy is routed to the sterilization chamber via a coaxial transmission line where small quantities of water couple strongly with the incident radiation to produce a superheated vapor phase. The efficiency of energy transfer is enhanced through the use of microwave susceptors within the sterilization chamber. Mating surfaces are thermally sterilized through direct contact with the hot gas. Efficacy has been demonstrated using the thermophile Bacillus stearothermophilus.

  9. Effect of low dose and moderate dose gamma irradiation on the mechanical properties of bone and soft tissue allografts.

    PubMed

    Balsly, Colleen R; Cotter, Andrew T; Williams, Lisa A; Gaskins, Barton D; Moore, Mark A; Wolfinbarger, Lloyd

    2008-12-01

    The increased use of allograft tissue for musculoskeletal repair has brought more focus to the safety of allogenic tissue and the efficacy of various sterilization techniques. Gamma irradiation is an effective method for providing terminal sterilization to biological tissue, but it is also reported to have deleterious effects on tissue mechanics in a dose-dependent manner. At irradiation ranges up to 25 kGy, a clear relationship between mechanical strength and dose has yet to be established. The aim of this study was to investigate the mechanical properties of bone and soft tissue allografts, irradiated on dry ice at a low absorbed dose (18.3-21.8 kGy) and a moderate absorbed dose (24.0-28.5 kGy), using conventional compressive and tensile testing, respectively. Bone grafts consisted of Cloward dowels and iliac crest wedges, while soft tissue grafts consisted of patellar tendons, anterior tibialis tendons, semitendinosus tendons, and fascia lata. There were no statistical differences in mechanical strength or modulus of elasticity for any graft irradiated at a low absorbed dose, compared to control groups. Also, bone allografts and two soft tissue allografts (anterior tibialis and semitendinosus tendon) that were irradiated at a moderate dose demonstrated similar strength and modulus of elasticity values to control groups. The results of this study support the use of low dose and moderate dose gamma irradiation of bone grafts. For soft tissue grafts, the results support the use of low dose irradiation.

  10. Prevalence, assessment, and antimicrobial resistance patterns of Salmonella from raw chicken eggs in Haramaya, Ethiopia.

    PubMed

    Kemal, Jelalu; Sibhat, Berhanu; Menkir, Sissay; Beyene, Desta

    2016-11-24

    The presence of antimicrobial-resistant Salmonella in poultry and poultry products, including eggs, is a global public health concern. This study aimed to estimate the levels and patterns of antimicrobial resistance of Salmonella from chicken eggs and assess consumers' raw egg consumption and farmers' handling practices. A total of 300 egg samples were collected from Haramaya open market (n = 150) and Haramaya University poultry farm (n = 150) in Ethiopia. Questionnaires were administered to egg sellers and buyers. A sterile cotton swab was used to sample the surface of eggs. The shells were sterilized and the egg content sampled. Isolation was done using the conventional methods for the detection of Salmonella, following the standard guidelines from ISO 6579. Sensitivity to 12 selected antibiotics was tested following the procedure of the Clinical and Laboratory Standards Institute. A level of 5.3% was observed among eggs shells from the open market and 0% among egg shells from the poultry farm, for an overall level of 2.7%. There was a significant difference (p = 0.004) between the prevalence of Salmonella spp. in sample site and sample type. Of the antimicrobials tested, Salmonella isolates were all resistant to erythromycin and clindamycin. Isolates were sensitive to ciprofloxacin (100%) and chloramphenicol (87.5%). All isolates were resistant to multiple antibiotics. One-third of the consumers were found to have eaten raw eggs for perceived medicinal values. To minimize the potential contamination of eggs by pathogens, the eggs should be properly handled, transported, and stored.

  11. Comparison of lignocaine gel-soaked Falope rings vs rectal diclofenac suppository for pain relief in laparoscopic sterilization.

    PubMed

    Sharma, Jai Bhagwan; Ghosh, Bhaswati; Kumar, Praveen; Mittal, Suneeta; Kumar, Sunesh; Roy, Kallol Kumar

    2011-01-01

    To compare the analgesic efficacy of lignocaine gel-soaked Silastic bands compared with rectal diclofenac suppositories in patients undergoing interval laparoscopic sterilization under conscious sedation. Prospective, randomized, controlled, single-blinded, clinical trial. Day-case center in a tertiary care hospital in India. Ninety-six women undergoing interval laparoscopic sterilization using Silastic bands (Yoon rings) randomly allocated by computer-generated random numbers into 3 groups. All women received intravenous sedation with injection diazepam and pentazocine along with local infiltration lignocaine injected at the site of the incision meant for insertion of the single site laparocator. In group 1 (n = 32), the Silastic bands (Falope rings) were presoaked in 2% sterile lignocaine gel; in group 2 (n = 32), women received a 100-mg rectal diclofenac suppository while on the operating table; and women in group 3 received only conventional analgesic. Pain perception was assessed using an 11-point visual analog score just after the procedure while still on the table (zero minutes), at 30 minutes and 1 hour after the procedure, and at discharge. The women in all 3 groups were comparable insofar as age and parity. At zero minutes (while on the operating table), the pain score in all 3 groups was similar. However, the pain scores at 30 and 60 minutes, and at discharge were significantly lower in groups 1 and group 2 compared with group 3. However, 2 women (6.25%) in group 2 and 6 (18.75%) in group 3 required supplemental analgesia within 1 hour, and were administered a 500-mg oral dose of mefenamic acid. The need for further analgesia was significantly lower in groups 1 and 2 compared with group 3 (p = .02). Comparison of groups 1 and 3 revealed that in group 1, the pain scores were significantly lower at 30 minutes (p = .02), 1 hour (p = .005), and at discharge (p = .004). No patients in group 1 requested analgesia, whereas 6 women in group 3 asked for further analgesia within an hour postoperatively (p = .01). Similarly in groups 2 and 3, women who received diclofenac suppositories had significantly lower pain scores at the specified intervals (p = 0.02, 0.002, and 0.02, respectively). Application of lignocaine gel to Falope rings and preoperative insertion of a rectal diclofenac suppository are simple and effective measures for pain control in the early postoperative period in patients undergoing day-case laparoscopic sterilization under conscious sedation. Either method could be incorporated into routine practice, depending on patient and physician choice. Copyright © 2010 AAGL. Published by Elsevier Inc. All rights reserved.

  12. Combining the Sterile Insect Technique with Wolbachia-Based Approaches: II- A Safer Approach to Aedes albopictus Population Suppression Programmes, Designed to Minimize the Consequences of Inadvertent Female Release

    PubMed Central

    Zhang, Dongjing; Lees, Rosemary Susan; Xi, Zhiyong; Gilles, Jeremie R. L.; Bourtzis, Kostas

    2015-01-01

    Due to the absence of a perfect method for mosquito sex separation, the combination of the sterile insect technique and the incompatible insect technique is now being considered as a potentially effective method to control Aedes albopictus. In this present study first we examine the minimum pupal irradiation dose required to induce complete sterility in Wolbachia triple-infected (HC), double-infected (GUA) and uninfected (GT) female Ae. albopictus. The HC line is a candidate for Ae. albopictus population suppression programmes, but due to the risk of population replacement which characterizes this triple infected line, the individuals to be released need to be additionally irradiated. After determining the minimum irradiation dose required for complete female sterility, we test whether sterilization is sufficient to prevent invasion of the triple infection from the HC females into double-infected (GUA) populations. Our results indicate that irradiated Ae. albopictus HC, GUA and GT strain females have decreased fecundity and egg hatch rate when irradiated, inversely proportional to the dose, and the complete sterilization of females can be acquired by pupal irradiation with doses above 28 Gy. PCR-based analysis of F1 and F2 progeny indicate that the irradiated HC females, cannot spread the new Wolbachia wPip strain into a small cage GUA population, released at a 1:5 ratio. Considering the above results, we conclude that irradiation can be used to reduce the risk of population replacement caused by an unintentional release of Wolbachia triple-infected Ae. albopictus HC strain females during male release for population suppression. PMID:26252474

  13. Shell-vial culture, coupled with real-time PCR, applied to Rickettsia conorii and Rickettsia massiliae-Bar29 detection, improving the diagnosis of the Mediterranean spotted fever.

    PubMed

    Segura, Ferran; Pons, Immaculada; Sanfeliu, Isabel; Nogueras, María-Mercedes

    2016-04-01

    Rickettsia conorii and Rickettsia massiliae-Bar29 are related to Mediterranean spotted fever (MSF). They are intracellular microorganisms. The Shell-vial culture assay (SV) improved Rickettsia culture but it still has some limitations: blood usually contains low amount of microorganisms and the samples that contain the highest amount of them are non-sterile. The objectives of this study were to optimize SV culture conditions and monitoring methods and to establish antibiotic concentrations useful for non-sterile samples. 12 SVs were inoculated with each microorganism, incubated at different temperatures and monitored by classical methods and real-time PCR. R. conorii was detected by all methods at all temperatures since 7th day of incubation. R. massiliae-Bar29 was firstly observed at 28°C. Real-time PCR allowed to detected it 2-7 days earlier (depend on temperature) than classical methods. Antibiotics concentration needed for the isolation of these Rickettsia species from non-sterile samples was determined inoculating SV with R. conorii, R. massiliae-Bar29, biopsy or tick, incubating them with different dilutions of antibiotics and monitoring them weekly. To sum up, if a MSF diagnosis is suspected, SV should be incubated at both 28°C and 32°C for 1-3 weeks and monitored by a sensitive real-time PCR. If the sample is non-sterile the panel of antibiotics tested can be added. Copyright © 2016 Elsevier GmbH. All rights reserved.

  14. Optimization of the magnetic horn for the nuSTORM non-conventional neutrino beam using the genetic algorithm

    DOE PAGES

    Liu, A.; Bross, A.; Neuffer, D.

    2015-05-28

    This paper describes the strategy for optimizing the magnetic horn for the neutrinos from STORed Muons (nuSTORM) facility. The nuSTORM magnetic horn is the primary collection device for the secondary particles generated by bombarding a solid target with 120 GeV protons. As a consequence of the non-conventional beamline designed for nuSTORM, the requirements on the horn are different from those for a conventional neutrino beamline. At nuSTORM, muons decay while circulating in the storage ring, and the detectors are placed downstream of the production straight so as to be exposed to the neutrinos from muon decay. nuSTORM aims at preciselymore » measuring the neutrino cross sections, and providing a definitive statement about the existence of sterile neutrinos. The nuSTORM horn aims at focusing the pions into a certain phase space so that more muons from pion decay can be accepted by the decay ring. The paper demonstrates a numerical method that was developed to optimize the horn design to gain higher neutrino flux from the circulating muons. A Genetic Algorithm (GA) was applied to the simultaneous optimization of the two objectives in this study. In conclusion, the application of the technique discussed in this paper is not limited to either the nuSTORM facility or muon based facilities, but can be used for other neutrino facilities that use magnetic horns as collection devices.« less

  15. Production of engineered long-life and male sterile Pelargonium plants

    PubMed Central

    2012-01-01

    Background Pelargonium is one of the most popular garden plants in the world. Moreover, it has a considerable economic importance in the ornamental plant market. Conventional cross-breeding strategies have generated a range of cultivars with excellent traits. However, gene transfer via Agrobacterium tumefaciens could be a helpful tool to further improve Pelargonium by enabling the introduction of new genes/traits. We report a simple and reliable protocol for the genetic transformation of Pelargonium spp. and the production of engineered long-life and male sterile Pelargonium zonale plants, using the pSAG12::ipt and PsEND1::barnase chimaeric genes respectively. Results The pSAG12::ipt transgenic plants showed delayed leaf senescence, increased branching and reduced internodal length, as compared to control plants. Leaves and flowers of the pSAG12::ipt plants were reduced in size and displayed a more intense coloration. In the transgenic lines carrying the PsEND1::barnase construct no pollen grains were observed in the modified anther structures, which developed instead of normal anthers. The locules of sterile anthers collapsed 3–4 days prior to floral anthesis and, in most cases, the undeveloped anther tissues underwent necrosis. Conclusion The chimaeric construct pSAG12::ipt can be useful in Pelargonium spp. to delay the senescence process and to modify plant architecture. In addition, the use of engineered male sterile plants would be especially useful to produce environmentally friendly transgenic plants carrying new traits by preventing gene flow between the genetically modified ornamentals and related plant species. These characteristics could be of interest, from a commercial point of view, both for pelargonium producers and consumers. PMID:22935247

  16. Production of engineered long-life and male sterile Pelargonium plants.

    PubMed

    García-Sogo, Begoña; Pineda, Benito; Roque, Edelín; Antón, Teresa; Atarés, Alejandro; Borja, Marisé; Beltrán, José Pío; Moreno, Vicente; Cañas, Luis Antonio

    2012-08-31

    Pelargonium is one of the most popular garden plants in the world. Moreover, it has a considerable economic importance in the ornamental plant market. Conventional cross-breeding strategies have generated a range of cultivars with excellent traits. However, gene transfer via Agrobacterium tumefaciens could be a helpful tool to further improve Pelargonium by enabling the introduction of new genes/traits. We report a simple and reliable protocol for the genetic transformation of Pelargonium spp. and the production of engineered long-life and male sterile Pelargonium zonale plants, using the pSAG12::ipt and PsEND1::barnase chimaeric genes respectively. The pSAG12::ipt transgenic plants showed delayed leaf senescence, increased branching and reduced internodal length, as compared to control plants. Leaves and flowers of the pSAG12::ipt plants were reduced in size and displayed a more intense coloration. In the transgenic lines carrying the PsEND1::barnase construct no pollen grains were observed in the modified anther structures, which developed instead of normal anthers. The locules of sterile anthers collapsed 3-4 days prior to floral anthesis and, in most cases, the undeveloped anther tissues underwent necrosis. The chimaeric construct pSAG12::ipt can be useful in Pelargonium spp. to delay the senescence process and to modify plant architecture. In addition, the use of engineered male sterile plants would be especially useful to produce environmentally friendly transgenic plants carrying new traits by preventing gene flow between the genetically modified ornamentals and related plant species. These characteristics could be of interest, from a commercial point of view, both for pelargonium producers and consumers.

  17. Real-time evaluation of two light delivery systems for photodynamic disinfection of Candida albicans biofilm in curved root canals.

    PubMed

    Sabino, C P; Garcez, A S; Núñez, S C; Ribeiro, M S; Hamblin, M R

    2015-08-01

    Antimicrobial photodynamic therapy (APDT) combined with endodontic treatment has been recognized as an alternative approach to complement conventional root canal disinfection methods on bacterial biofilms. We developed an in  vitro model of bioluminescent Candida albicans biofilm inside curved dental root canals and investigated the microbial reduction produced when different light delivery methods are employed. Each light delivery method was evaluated in respect to the light distribution provided inside curved root canals. After conventional endodontic preparation, teeth were sterilized before canals were contaminated by a bioluminescent strain of C. albicans (CEC789). Methylene blue (90 μM) was introduced into the canals and then irradiated (λ = 660 nm, P = 100 mW, beam diameter = 2 mm) with laser tip either in contact with pulp chamber or within the canal using an optical diffuser fiber. Light distribution was evaluated by CCD camera, and microbial reduction was monitored through bioluminescence imaging. Our findings demonstrated that the bioluminescent C. albicans biofilm model had good reproducibility and uniformity. Light distribution in dental tissue was markedly dependent on the light delivery system, and this strategy was directly related to microbial destruction. Both light delivery systems performed significant fungal inactivation. However, when irradiation was performed with optical diffuser fiber, microbial burden reduction was nearly 100 times more effective. Bioluminescence is an interesting real-time analysis to endodontic C. albicans biofilm inactivation. APDT showed to be an effective way to inactivate C. albicans biofilms. Diffuser fibers provided optimized light distribution inside curved root canals and significantly increased APDT efficiency.

  18. Real-time evaluation of two light delivery systems for photodynamic disinfection of Candida albicans biofilm in curved root canals

    PubMed Central

    Sabino, C. P.; Garcez, A. S.; Núñez, S. C.; Ribeiro, M. S.; Hamblin, M. R.

    2014-01-01

    Antimicrobial photodynamic therapy (APDT) combined with endodontic treatment has been recognized as an alternative approach to complement conventional root canal disinfection methods on bacterial biofilms. We developed an in vitro model of bioluminescent Candida albicans biofilm inside curved dental root canals and investigated the microbial reduction produced when different light delivery methods are employed. Each light delivery method was evaluated in respect to the light distribution provided inside curved root canals. After conventional endodontic preparation, teeth were sterilized before canals were contaminated by a bioluminescent strain of C. albicans (CEC789). Methylene blue (90 µM) was introduced into the canals and then irradiated (λ=660 nm, P=100 mW, beam diameter=2 mm) with laser tip either in contact with pulp chamber or within the canal using an optical diffuser fiber. Light distribution was evaluated by CCD camera, and microbial reduction was monitored through bioluminescence imaging. Our findings demonstrated that the bioluminescent C. albicans biofilm model had good reproducibility and uniformity. Light distribution in dental tissue was markedly dependent on the light delivery system, and this strategy was directly related to microbial destruction. Both light delivery systems performed significant fungal inactivation. However, when irradiation was performed with optical diffuser fiber, microbial burden reduction was nearly 100 times more effective. Bioluminescence is an interesting real-time analysis to endodontic C. albicans biofilm inactivation. APDT showed to be an effective way to inactivate C. albicans biofilms. Diffuser fibers provided optimized light distribution inside curved root canals and significantly increased APDT efficiency. PMID:25060900

  19. Spacecraft Sterilization Using Non-Equilibrium Atmospheric Pressure Plasma

    NASA Technical Reports Server (NTRS)

    Cooper, Moogega; Vaze, Nachiket; Anderson, Shawn; Fridman, Gregory; Vasilets, Victor N.; Gutsol, Alexander; Tsapin, Alexander; Fridman, Alexander

    2007-01-01

    As a solution to chemically and thermally destructive sterilization methods currently used for spacecraft, non-equilibrium atmospheric pressure plasmas are used to treat surfaces inoculated with Bacillus subtilis and Deinococcus radiodurans. Evidence of significant morphological changes and reduction in viability due to plasma exposure will be presented, including a 4-log reduction of B. subtilis after 2 minutes of dielectric barrier discharge treatment.

  20. Comparison of the effects of gamma irradiation and steam sterilization on Southern pine sapwood

    Treesearch

    Simon Curling; Jerrold E. Winandy

    2008-01-01

    Gamma irradiation is a commonly used method of sterilization of wood specimens prior to decay testing. As part of a larger series of studies, an investigation was made into the effects of gamma irradiation on flexural bending strength properties and its corresponding relationship to changes in lignin and hemicellulosic contents of wood after exposure to various dose...

  1. Insulin compatibility with polymer materials used in external pump infusion systems.

    PubMed

    Melberg, S G; Havelund, S; Villumsen, J; Brange, J

    1988-04-01

    In a study designed to mimic actual user conditions for external insulin pump infusion, the insulin quality after passage through the infusion set was assessed by various analytical methods, including high performance liquid chromatography. The two infusion sets tested consisted of, firstly, a polyvinylchloride/rubber syringe and a polyvinylchloride catheter sterilized by gamma irradiation and, secondly, a polyethylene/polypropylene syringe connected to a polyethylene catheter and sterilized by ethylene oxide. The insulin solution delivered through the PVC infusion set showed a reduction of preservative to less than 30% of the initial content and increased formation of chemical transformation products of insulin varying from twice the reference level during the first day to more than three times on the third day. By contrast, the polyethylene/polypropylene infusion system showed only a minor decrease in preservative content and no increase in chemical transformation. These effects were observed irrespective of the brand of insulin and were not affected by increase of the zinc content of the insulin solution. Investigation of the influence of the sterilization methods performed on polyvinylchloride and polyethylene catheters revealed that gamma irradiated polyvinylchloride catheters were markedly harmful to the insulin solution, whereas ethylene oxide sterilization did not influence the chemical stability of insulin.

  2. Looking for Sterile Neutrinos via Neutral-Current Disappearance with NOvA

    NASA Astrophysics Data System (ADS)

    Yang, Shaokai; NOvA Collaboration

    2017-01-01

    Contradictory evidence has been presented on the issue of neutrino mixing between the three known active neutrinos and light sterile neutrinos. The excess of events as seen by the LSND and MiniBooNE experiments interpreted as short-baseline neutrino oscillations, the collective evidence of the reactor neutrino anomaly, and the gallium anomaly all point towards sterile neutrinos with mass at the 1 eV level. While these results are tantalizing, they are not conclusive as they are in tension with null results from other short-baseline experiments, and with disappearance searches in long-baseline and atmospheric experiments. Resolving the issue of the existence of light sterile neutrinos has profound implications for both particle physics and cosmology. The NOvA (NuMI Off-Axis νe Appearance) experiment may help clarify the situation by searching for disappearance of active neutrinos from the NuMI (Neutrinos from the Main Injector) beam over a baseline of 810 km. In this talk, we will describe a method of how NOvA can look for oscillations into sterile neutrinos, with focus on disappearance of neutral current (NC) neutrino events, will present the first analysis result of this search, discuss their implications in constraining the existence of light sterile neutrinos, and the planned updates to this analysis.

  3. Cytological characterization of a thermo-sensitive cytoplasmic male-sterile wheat line having K-type cytoplasm of Aegilops kotschyi.

    PubMed

    Meng, Liying; Liu, Zihan; Zhang, Lingli; Hu, Gan; Song, Xiyue

    2016-12-01

    Male sterility is an important tool for obtaining crop heterosis. A thermo-sensitive cytoplasmic male-sterile (TCMS) line was developed recently using a new method based on tiller regeneration. In the present study, we explored the critical growth stages required to maintain thermo-sensitive male sterility in TCMS lines and found that fertility is associated with abnormal tapetal and microspore development. We investigated the fertility and cytology of temperature-treated plant anthers at various developmental stages. TCMS line KTM3315A exhibited thermo-sensitive male sterility in Zadoks growth stages 41-49 and 58-59. Morphologically, the line exhibited thermo-sensitive male sterility at 3-9 days before heading and at 3-6 days before flowering, and it was partially restored in three locations during spring and summer. TCMS line KTM3315A plants exhibited premature tapetal programmed cell death (PCD) from the early uninucleate stage of microspore development until the tapetal cells degraded completely. Microspore development was then blocked and the pollen abortion type was stainable abortion. Thus, male fertility in the line KTM3315A is sensitive to temperature and premature tapetal PCD is the main cause of pollen abortion, where it determines the starting period and affects male fertility conversion in K-type TCMS lines at certain temperatures.

  4. On the 100th anniversary of sterile catgut kuhn: Franz Kuhn (1866-1929) and the epistemology of catgut sterilization.

    PubMed

    Dietz, Ulrich A; Kehl, Franz; Hamelmann, Wulf; Weisser, Christoph

    2007-12-01

    The long road to effective catgut sterilization began with the work of Lord Joseph Lister (1867) and did not end until 40 years later. At the end of the nineteenth century dozens of different techniques were used to "sterilize" catgut, by immersing the cord in a cold chemical solution, by exposing it to steam, or by a combination of the two techniques, yet none of these approaches offered the ultimate solution. One of the many physicians working on the catgut problem at that time was the German surgeon Franz Kuhn (1866-1929), best known as a pioneer of intubation anesthesia. This review offers a brief biographical sketch of Kuhn's life and career on the occasion of the centenary of Sterile Catgut Kuhn. The goal of the present study is to describe several landmarks in the development of the catgut sterilization method. To explain this process, two approaches are taken: first, an analysis to see whether the character traits of the typical surgeon at that time provided the soil in which innovation could thrive, and second, an epistemological examination of the conceptual models for the attainment of knowledge current at that time. Perspectives for the future are explored in light of the "imperative of responsibility" of Hans Jonas.

  5. Microbiological evaluation of the steam sterilization of assembled laparoscopic instruments 1

    PubMed Central

    de Camargo, Tamara Carolina; Graziano, Kazuko Uchikawa; Almeida, Alda Graciele Claudio dos Santos; Suzuki, Karina; da Silva, Cely Barreto; Pinto, Flávia Morais Gomes

    2016-01-01

    ABSTRACT Objective: assess the safety of steam sterilization of assembled laparoscopic instruments with challenge contamination. Method: a laboratory experimental study, using as test samples trocars and laparoscopic graspers. Geobacillus stearothermophillus ATCC-7953 was used, with a microbial population of 106UFC/Filter paper substrate, removed from the biological indicator. Three of them were introduced into each instrument at the time of assembly, and sterilized at pressurized saturated steam, 134oC for 5 minutes. After sterilization, the instrument was disassembled and each filter paper substrate was inoculated in soybean casein culture and incubated at 56oC for 21 days. In case of absence of growth, they were subjected to heat shock of 80oC, for 20 minutes and re-incubated for 72 hours. Sample size: 185 graspers and 185 trocars, with 95% power. We paired the experiments with comparative negative control groups (5 graspers and 5 trocars with challenge contamination, sterilized disassembled) and positive control (30 filter paper supports, unsterilized), subject to the same incubation procedures. Results: there was no microbial growth in experimental and negative control. The results of the positive control were satisfactory. Conclusion: this study provided strong scientific evidence to support the safety of steam sterilizing of the assembled laparoscopic instrument. PMID:27878222

  6. Sterilization for family planning in a Third World country.

    PubMed

    Reichert, J A; Nagel, L W; Solberg, N S

    1997-07-01

    Outpatient laparoscopy procedures have made sterilization possible for millions of women in developing countries. This report describes the experience of a team of doctors, nurses, and support staff that performed 107 laparoscopic tubal sterilizations during on eight-day sojourn in a remote north-central area of Nicaragua. Minimal analgesia (oral ibuprofen) and anesthesia (1% lidocaine) were used since most of the patients walked to and from the hospital-some up to 15 miles. Because the Nicaraguan government's support for birth-control programs is unreliable and because illegal abortion is the leading cause of maternal mortality in Nicaragua, this safe, minimally invasive surgical method is the favored means of birth control.

  7. Low temperature gamma sterilization of a bioresorbable polymer, PLGA

    NASA Astrophysics Data System (ADS)

    Davison, Lisa; Themistou, Efrosyni; Buchanan, Fraser; Cunningham, Eoin

    2018-02-01

    Medical devices destined for insertion into the body must be sterilised before implantation to prevent infection or other complications. Emerging biomaterials, for example bioresorbable polymers, can experience changes in their properties due to standard industrial sterilization processes. Gamma irradiation is one of the most reliable, large scale sterilization methods, however it can induce chain scission, cross-linking or oxidation reactions in polymers. sterilization at low temperature or in an inert atmosphere has been reported to reduce the negative effects of gamma irradiation. The aim of this study was to investigate the impact of low temperature sterilization (at -80 °C) when compared to sterilization at ambient temperature (25 °C) both in inert atmospheric conditions of nitrogen gas, on poly(lactide co-glycolide) (PLGA). PLGA was irradiated at -80 and 25 °C at 40 kGy in a nitrogen atmosphere. Samples were characterised using differential scanning calorimetry (DSC), tensile test, Fourier transform infrared (FTIR) spectroscopy, proton nuclear magnetic resonance (1H NMR) spectroscopy and gel permeation chromatography (GPC). The results showed that the molecular weight was significantly reduced as was the glass transition temperature, an indication of chain scission. FTIR showed small changes in chemical structure in the methyl and carbonyl groups after irradiation. Glass transition temperature was significantly different between irradiation at -80 °C and irradiation at 25 °C, however this was a difference of only 1 °C. Ultimately, the results indicate that the sterilization temperature used does not affect PLGA when carried out in a nitrogen atmosphere.

  8. The Validation of Vapor Phase Hydrogen Peroxide Microbial Reduction for Planetary Protection and a Proposed Vacuum Process Specification

    NASA Technical Reports Server (NTRS)

    Chung, Shirley; Barengoltz, Jack; Kern, Roger; Koukol, Robert; Cash, Howard

    2006-01-01

    The Jet Propulsion Laboratory, in conjunction with the NASA Planetary Protection Officer, has selected the vapor phase hydrogen peroxide sterilization process for continued development as a NASA approved sterilization technique for spacecraft subsystems and systems. The goal is to include this technique, with an appropriate specification, in NPR 8020.12C as a low temperature complementary technique to the dry heat sterilization process.To meet microbial reduction requirements for all Mars in-situ life detection and sample return missions, various planetary spacecraft subsystems will have to be exposed to a qualified sterilization process. This process could be the elevated temperature dry heat sterilization process (115 C for 40 hours) which was used to sterilize the Viking lander spacecraft. However, with utilization of such elements as highly sophisticated electronics and sensors in modern spacecraft, this process presents significant materials challenges and is thus an undesirable bioburden reduction method to design engineers. The objective of this work is to introduce vapor hydrogen peroxide (VHP) as an alternative to dry heat microbial reduction to meet planetary protection requirements.The VHP process is widely used by the medical industry to sterilize surgical instruments and biomedical devices, but high doses of VHP may degrade the performance of flight hardware, or compromise material properties. Our goal for this study was to determine the minimum VHP process conditions to achieve microbial reduction levels acceptable for planetary protection.

  9. Effects of Processing and Medical Sterilization Techniques on 3D-Printed and Molded Polylactic Acid

    NASA Astrophysics Data System (ADS)

    Geritano, Mariah Nicole

    Manufacturing industries have evolved tremendously in the past decade with the introduction of Additive Manufacturing (AM), also known as 3D Printing. The medical device industry has been a leader in adapting this new technology into research and development. 3D printing enables medical devices and implants to become more customizable, patient specific, and allows for low production numbers. This study compares the mechanical and thermal properties of traditionally manufactured parts versus parts manufactured through 3D printing before and after sterilization, and the ability of an FDM printer to produce reliable, identical samples. It was found that molded samples and 100% infill high-resolution samples have almost identical changes in properties when exposed to different sterilization methods, and similar cooling rates. The data shown throughout this investigation confirms that manipulation of printing parameters can result in an object with comparable material properties to that created through traditional manufacturing methods.

  10. A comprehensive and efficient process for counseling patients desiring sterilization.

    PubMed

    Haws, J M; Butta, P G; Girvin, S

    1997-06-01

    To optimize the time spent counseling a sterilization patient, this article presents a 10-step process that includes all steps necessary to ensure a comprehensive counseling session: (1) Discuss current contraception use and all available methods; (2) assess the client's interest in/readiness for sterilization; (3) emphasize that the procedure is meant to be permanent, but there is a possibility of failure; (4) explain the surgical procedure using visuals, and include a discussion of benefits and risks; (5) explain privately to the client the need to use condoms if engaging in risky sexual activity; (6) have the client read and sign an informed consent form; (7) schedule an appointment for the procedure and provide the patient with a copy of all necessary paperwork; (8) discuss cost and payment method; (9) provide written preoperative and postoperative instructions; and (10) schedule a postoperation visit, or a postoperation semen analysis.

  11. Determination of Root Exudates in a Steril Continuous Flow Culture. I. The Culture Method

    PubMed Central

    Richter, Martin; Wilms, Werner; Scheffer, Fritz

    1968-01-01

    A sterile plant culture consisting of culture vessels, culture solution container, collecting flasks for percolating nutrient solution, illumination and aeration systems and a suitable pump is described. Its difference with other culture methods is a very slow, continuous percolation of the nutrient solution through the rooting medium. Well defined and controllable conditions can thus be established in the rhizosphere over long culture periods. Samples can be collected at short intervals without disturbing the rhizosphere in any way nor endangering the sterility of the culture. One of the fundamental factors determining the special ecological characteristics of the plant rhizosphere is the liberation of organic and inorganic substances by the plant root. During the study of this phenomenon it became evident that the amount of substances liberated varies within wide limits (factors 100 to 1000) according to the conditions in which the root is developing. PMID:16656966

  12. Inhaled medicinal cannabis and the immunocompromised patient.

    PubMed

    Ruchlemer, Rosa; Amit-Kohn, Michal; Raveh, David; Hanuš, Lumír

    2015-03-01

    Medicinal cannabis is an invaluable adjunct therapy for pain relief, nausea, anorexia, and mood modification in cancer patients and is available as cookies or cakes, as sublingual drops, as a vaporized mist, or for smoking. However, as with every herb, various microorganisms are carried on its leaves and flowers which when inhaled could expose the user, in particular immunocompromised patients, to the risk of opportunistic lung infections, primarily from inhaled molds. The objective of this study was to identify the safest way of using medicinal cannabis in immunosuppressed patients by finding the optimal method of sterilization with minimal loss of activity of cannabis. We describe the results of culturing the cannabis herb, three methods of sterilization, and the measured loss of a main cannabinoid compound activity. Systematic sterilization of medicinal cannabis can eliminate the risk of fatal opportunistic infections associated with cannabis among patients at risk.

  13. Effects of Low-Temperature Plasma-Sterilization on Mars Analog Soil Samples Mixed with Deinococcus radiodurans.

    PubMed

    Schirmack, Janosch; Fiebrandt, Marcel; Stapelmann, Katharina; Schulze-Makuch, Dirk

    2016-05-26

    We used Ar plasma-sterilization at a temperature below 80 °C to examine its effects on the viability of microorganisms when intermixed with tested soil. Due to a relatively low temperature, this method is not thought to affect the properties of a soil, particularly its organic component, to a significant degree. The method has previously been shown to work well on spacecraft parts. The selected microorganism for this test was Deinococcus radiodurans R1, which is known for its remarkable resistance to radiation effects. Our results showed a reduction in microbial counts after applying a low temperature plasma, but not to a degree suitable for a sterilization of the soil. Even an increase of the treatment duration from 1.5 to 45 min did not achieve satisfying results, but only resulted in in a mean cell reduction rate of 75% compared to the untreated control samples.

  14. A New Diagnostic Resource for Ceratitis capitata Strain Identification Based on QTL Mapping

    PubMed Central

    Sim, Sheina B.; Ruiz-Arce, Raul; Barr, Norman B.; Geib, Scott M.

    2017-01-01

    The Mediterranean fruit fly Ceratitis capitata (Wiedemann) is a destructive agricultural pest and the subject of exclusion efforts in many countries. Suppression and eradication of invasive populations to prevent its establishment is facilitated by the release of sterile males using the sterile insect technique (SIT). In SIT release areas, it is critical to accurately discriminate between released sterile males and wild individuals to detect extremely rare invasive individuals in areas inundated with millions of sterile male flies. Current methods for discrimination exist but are not always definitive, and a more reliable method is necessary. To address this, we developed a genotyping assay that can be used to discriminate between sterile males from the SIT strain and wild individuals. This was achieved by identifying single nucleotide polymorphisms (SNPs) linked to the maintained traits that facilitate male-only releases, white pupae (wp) and temperature-sensitive lethal (tsl), via QTL mapping. This resulted in the identification of one SNP that was in near-perfect linkage disequilibrium between genotype at this locus and the pupal color phenotype. Medfly from many SIT colonies and wild individuals from across its geographic range were genotyped for this locus, and results show its consistency in identifying SIT flies. In addition, linkage and QTL mapping of wp and tsl have larger impacts as they can serve as foundational tools to identify the genetic basis of traits that facilitate the separation of males from female flies, which can be used to develop SIT programs in related species. PMID:28889103

  15. Fracture resistance behaviour of gamma-irradiation sterilized cortical bone protected with a ribose pre-treatment

    NASA Astrophysics Data System (ADS)

    Woodside, Carman Mitchell

    Structural bone allograft reconstructions are often implemented to repair large skeletal defects. To ensure the biological safety of the patient, allograft material is routinely sterilized with gamma-irradiation prior to implantation. The sterilization process damages the tissue, specifically the collagen protein network, leading to severe losses in the mechanical properties of the bone. Our lab has begun developing a ribose pre-treatment that can protect bone from these harmful effects. The goals of the present study were to develop a method to measure the fracture toughness of bone, an important clinical failure mode, and implement it to determine the effectiveness of the ribose pre-treatment on fracture toughness. We have shown that the ribose pre-treatment is successful at protecting some of the original fracture toughness of sterilized bone, and that the connectivity of the collagen network is an important contributor to the fracture resistance of bone.

  16. Plant development in the absence of epiphytic microorganisms

    NASA Astrophysics Data System (ADS)

    Kutschera, U.; Koopmann, V.; Grotha, R.

    2002-05-01

    Microorganisms (bacteria, fungi) are common residents of the roots, stems and leaves of higher plants. In order to explore the dependency of plant development on the presence of epiphytic microorganisms, the achenes (seeds) of sunflower (Helianthus annuus L.) were sterilized and germinated under aseptic conditions. The sterility of the seedlings was determined with the agar impression method. In seedlings from non-sterile seeds (control) that were likewise raised in a germ-free environment, all plant organs investigated (stem, cotyledons and primary leaves) were contaminated with bacteria. Hypocotyl elongation was not affected by epiphytic microorganisms. However, the growth rates of the cotyledons and primary leaves were higher in sterile seedlings compared with the control. The implications of this differential inhibition of organ development by epiphytic bacteria that are transmitted via the outer surface of the seed coat are discussed. We conclude that epiphytes in the above-ground phytosphere are not necessary for the development of the sunflower seedling.

  17. Acquisition and Retention of Sterile Compounding Accuracy Skills

    PubMed Central

    Brown, Michael C.; Valdovinos, Katie; Zavala, Pedro J.

    2017-01-01

    Objective. To determine the accuracy of dose of pharmacy students’ parenteral sterile preparation skills and to measure pharmacy students’ skill retention 1.5 years later. Methods. An exercise was designed to assess each student’s accuracy in compounding a sterile preparation with the correct potency during a second and then third year course. Results. Initially, the mean (standard deviation) of 141 students’ compounded preparation dose was not significantly different than the desired dose. Additionally, 91.5% of products were within 10% of the desired dose. In the follow-up activity the next academic year, the mean dose was not significantly different than the original compounded dose. Similarly 92.9% were within 10% of the desired dose. Conclusion. Students’ overall accuracy of sterile compounding was good initially and well-retained more than a year later, with more than 90% of students being within 10% of the desired dose in both courses. PMID:28970616

  18. Sealing and External Sterilization of a Sample Container

    NASA Technical Reports Server (NTRS)

    Bar-Cohen, Yoseph; Badescu, Mircea; Bao, Xiaoqi; Sherrit, Stewart; Olorunsola, Ayoola

    2008-01-01

    A method of (1) sealing a sample of material acquired in a possibly b iologically contaminated ("dirty") environment into a hermetic conta iner, (2) sterilizing the outer surface of the container, then (3) d elivering the sealed container to a clean environment has been propos ed. The method now proposed was originally intended to be used to ret urn samples from Mars to Earth, but could also be used on Earth to t ransport material samples acquired in environments that contain biol ogical hazards and/or, in some cases, chemical hazards.

  19. U.S. Compounding Pharmacy-related Outbreaks, 2001–2013—Public Health and Patient Safety Lessons Learned

    PubMed Central

    Shehab, Nadine; Brown, Megan N.; Kallen, Alexander J.; Perz, Joseph F.

    2015-01-01

    Objectives Pharmacy-compounded sterile preparations (P-CSPs) are frequently relied upon in U.S. healthcare, but are increasingly being linked to outbreaks of infections. We provide an updated overview of outbreak burden and characteristics, identify drivers of P-CSP demand, and discuss public health and patient safety lessons learned to help inform prevention. Methods Outbreaks of infections linked to contaminated P-CSPs that occurred between January 1, 2001 and December 31, 2013 were identified from internal Centers for Disease Control and Prevention reports, Food and Drug Administration drug safety communications, and published literature. Results We identified 19 outbreaks linked to P-CSPs, resulting in at least 1000 cases, including deaths. Outbreaks were reported across two-thirds of states, with almost one-half (8/19) involving cases in more than one state. Almost one-half of outbreaks were linked to injectable steroids (5/19) and intraocular bevacizumab (3/19). Non-patient-specific compounding originating from non-sterile ingredients and re-packaging of already sterile products were the most common practices associated with P-CSP contamination. Breaches in aseptic processing and deficiencies in sterilization procedures or in sterility/endotoxin testing were consistent findings. Hospital outsourcing, preference for variations of commercially available products, commercial drug shortages, and lower prices were drivers of P-CSP demand. Conclusions Recognized outbreaks linked to P-CSPs have been most commonly associated with non-patient-specific re-packaging and non-sterile to sterile compounding, and linked to lack of adherence to sterile compounding standards. Recently-enhanced regulatory oversight of compounding may improve adherence to such standards. Additional measures to limit and control these outbreaks include vigilance when outsourcing P-CSPs, scrutiny of drivers for P-CSP demand, and early recognition and notification of possible outbreaks. PMID:26001553

  20. Effects of autoclave sterilization on properties of dental rubber dam as related to its use as barrier membrane in guided tissue regeneration.

    PubMed

    Apinhasmit, Wandee; Limsombutanon, Somchai; Swasdison, Somporn; Suppipat, Nophadol

    2003-10-01

    Dental rubber dams (RDs) were used as barrier membranes in guided tissue regeneration for the treatment of periodontal intraosseous defects with acceptable clinical results. The aim of the present study was to investigate the effects of autoclave sterilization on properties of RD as related to its use as a barrier membrane in guided tissue regeneration. RDs were sterilized by either an autoclave, gamma irradiation, or chemical agents and then co-cultured with human gingival fibroblasts. The cell responses to sterilized RDs were investigated by inverted phase contrast microscopy, scanning electron microscopy (SEM) and 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) technique. The surface alterations of the autoclaved RDs were observed under SEM. The tensile strength, tear strength and elongation at break of the autoclaved RDs were tested by a universal testing machine. The results from cell culture, microscopic and MTT studies showed that RDs sterilized by autoclave and gamma irradiation did not deteriorate gingival fibroblasts and provided surfaces suitable for cell attachment, whereas chemical-sterilized RDs were toxic to these cells. Ultrastructurally, surface changes from the non-autoclaved RDs, including some melted areas, small pores and folds were observed on the autoclaved RD surface. The tensile strength and tear strength of the autoclaved RDs were significantly lower than those of the non-autoclaved RDs (p = 0.042, p < 0.001, respectively). In contrast, the elongation at break of the autoclaved RDs was higher than that of the non-autoclaved RDs (p < 0.001). These results suggest that the autoclave sterilization deteriorated the physical properties of RDs even though they seemed to be compatible to the cultured human cells. Therefore, the sterilization method should be taken into consideration when RDs are utilized as barrier membranes.

  1. Effect of dry heat and steam sterilization on load-deflection characteristics of β-titanium wires: An in vitro study

    PubMed Central

    Alavi, Shiva; Sinaee, Neda

    2012-01-01

    Background: Sterilization techniques could affect the characteristics of orthodontic wires. The aim of the present study was to evaluate the effect of steam and dry heat sterilization techniques on load-deflection behavior of five types of β-titanium alloy wires. Materials and Methods: The samples consisted of 30 straight lengths of five types of β-titanium alloy wires: Titanium Molybdenum Alloy (TMA) Low Friction (TMAL), TMA Low Friction Colored (HONE), Resolve (RES), BetaForce (BETA), and BETA CNA (CNA). Thirty wire segments were divided into three groups of 10. Group 1 was the control group and the group 2 samples were sterilized by dry heat in an oven (60 minutes at 160°C) and group 3 by steam in an autoclave (15 minutes at 121°C). Then all the wire samples underwent a three-point bending test in a testing machine to evaluate load-deflection properties. Data was analyzed by repeated measures ANOVA and Scheffé's test (α = 0.05). Results: The results showed that dry heat sterilization significantly increased force levels during both loading and unloading of CNA, BETA and RES and during loading of HONE (P < 0.05). Steam sterilization significantly increased force levels during both loading and unloading of BETA and during unloading of HONE (P < 0.05), with no effects on the load-deflection characteristics of TMAL, CNA and RES (P > 0.05). Conclusion: It appears dry heat sterilization increases stiffness of RES, BETA, CNA and HONE but autoclave sterilization did not have any effect on load-deflection characteristics of most of the β-titanium wires tested, indicating that clinicians who want to provide maximum safety for their patients can autoclave TMAL, RES and CNA before applying them. PMID:23559917

  2. Evaluation of tensile strength and surface topography of orthodontic wires after infection control procedures: An in vitro study.

    PubMed

    Brindha, M; Kumaran, N Kurunji; Rajasigamani, K

    2014-07-01

    The aim of this study is to evaluate, the influence of four types of sterilization/disinfection procedures (autoclave, hot air oven, glutaraldehyde, and ultraviolet [UV] light) on the tensile strength and surface topography of three orthodontic wires (stainless steel (SS), titanium - molybdenum alloy [TMA], and cobalt chromium (CoCr)). Sample comprised of three types of 8 inches straight length segments of orthodontic wires. They were divided into three groups according to wire composition comprising of 50 samples each. Totally 50 samples of each group were then equally divided into five subgroups according to sterilization method. After sterilization and disinfection of the experimental group, surface topography was examined with scanning electron microscope (SEM) and tensile strength was tested using universal testing machine. The results of this study show that the mean ultimate tensile strength (UTS) of SS wire after four sterilization procedures were similar to the control group (1845.815 ± 142.29 MPa). The mean UTS of TMA wire increases after four sterilization procedures when compared with the control group (874.107 ± 275.939 MPa). The mean UTS of CoCr wire remains same after UV light disinfection, but increases after other three sterilization procedures when compared with the control group (1449.759 ± 156.586 MPa). SEM photographs of the present study shows gross increase in pitting roughness of the surface topography of all the three types of wires after four types of sterilization. Orthodontists who want to offer maximum safety for their patients can sterilize orthodontic wires before placement, as it does not deteriorate the tensile strength and surface roughness of the alloys.

  3. Low-energy electron-beam treatment as alternative for on-site sterilization of highly functionalized medical products - A feasibility study

    NASA Astrophysics Data System (ADS)

    Gotzmann, G.; Portillo, J.; Wronski, S.; Kohl, Y.; Gorjup, E.; Schuck, H.; Rögner, F. H.; Müller, M.; Chaberny, I. F.; Schönfelder, J.; Wetzel, C.

    2018-09-01

    Over the last decades, the medical device industry has grown significantly. Complex and highly functionalized medical devices and implants are being developed to improve patient treatment and to enhance their health-related quality of life. However, medical devices from this new generation often cannot be sterilized by standard methods such as autoclaving or sterilizing gases, as they are temperature sensitive, containing electronic components like sensors and microchips, or consist of polymers. Gamma irradiation for sterilization of such products is also problematic due to long processing times under highly reactive conditions resulting in material degradation or loss of functionality. Low-energy electron-beam treatment could enable irradiation sterilization of medical surfaces within seconds. This method is very fast in comparison to gamma irradiation because of its high dose rate and therefore degradation processes of polymers can be reduced or even prevented. Additionally, electron penetration depth can be precisely controlled to prevent damage of sensitive components like electronics and semiconductors. The presented study focuses on two key aspects: 1.) Can new and highly functionalized medical products in future be sterilized using low-energy electron-beam irradiation; and 2.) Is the low-energy electron-beam technology suitable to be set up on-site to speed up sterilization processing or make it available "just-in-time". To address these questions, different test specimens were chosen with complex geometry or electronic functional parts to gather information about the limitations and chances for this new approach. The test specimens were inoculated with clinical relevant test organisms (Pseudomonas aeruginosa) as well as with approved radiation resistant organisms (Deinococcus radiodurans and Bacillus pumilus) to prove the suitability of low-energy electron-beam treatment for the above-mentioned medical products. The calculation of the D10 value for B. pumilus revealed equal efficacy when compared to standard high-energy irradiation sterilization. All of the above-mentioned germs were successfully inactivated by low-energy electron-beam treatment when test specimens were inoculated with a germ load > 10^6 CFU and treated with doses ≥ 10 kGy (for B. pumilus and P. aeruginosa) and > 300 kGy (for D. radiodurans) respectively. As an example, for specialized electronic components to be sterilized, an impedance sensor for cell culture applications was sterilized and unimpaired functionality was demonstrated even after five repeated sterilization cycles to a total dose of 50 kGy. To address the second aspect of on-site suitability of this technology, the product handling for low-energy electron-beam treatment had to be adapted to minimize the size of the electron-beam facility. Therefore, a mini electron-beam source was used and a specialized sample holder and 3D-handling regime were developed to allow reproducible surface treatment for complex product geometries. Inactivation of B. pumilus inoculated medical screws (> 10^6 CFU) was successful using the developed handling procedure. In addition, a packaging material (PET12/PE50) for medical products was investigated for its suitability for low-energy irradiation sterilization. Biocompatibility assessment revealed the material to be eligible for this application as even overdoses did not impair the biocompatibility of the material. With these results, the principal suitability of low-energy electron-beam treatment for sterilization of medical products containing electronics like sensors is demonstrated. The low-energy technology and the specialized 3D-handling regime allow the on-site setup of the technology in hospitals, medical practices or any other point of care.

  4. Microbiological testing of pharmaceuticals and cosmetics in Egypt.

    PubMed

    Zeitoun, Hend; Kassem, Mervat; Raafat, Dina; AbouShlieb, Hamida; Fanaki, Nourhan

    2015-12-09

    Microbial contamination of pharmaceuticals poses a great problem to the pharmaceutical manufacturing process, especially from a medical as well as an economic point of view. Depending upon the product and its intended use, the identification of isolates should not merely be limited to the United States Pharmacopeia (USP) indicator organisms. Eighty-five pre-used non-sterile pharmaceuticals collected from random consumers in Egypt were examined for the eventual presence of bacterial contaminants. Forty-one bacterial contaminants were isolated from 31 of the tested preparations. These isolates were subjected to biochemical identification by both conventional tests as well as API kits, which were sufficient for the accurate identification of only 11 out of the 41 bacterial contaminants (26.8%) to the species level. The remaining isolates were inconclusively identified or showed contradictory results after using both biochemical methods. Using molecular methods, 24 isolates (58.5%) were successfully identified to the species level. Moreover, polymerase chain reaction (PCR) assays were compared to standard biochemical methods in the detection of pharmacopoeial bacterial indicators in artificially-contaminated pharmaceutical samples. PCR-based methods proved to be superior regarding speed, cost-effectiveness and sensitivity. Therefore, pharmaceutical manufacturers would be advised to adopt PCR-based methods in the microbiological quality testing of pharmaceuticals in the future.

  5. Chitosan-Based Matrices Prepared by Gamma Irradiation for Tissue Regeneration: Structural Properties vs. Preparation Method.

    PubMed

    Casimiro, Maria Helena; Lancastre, Joana J H; Rodrigues, Alexandra P; Gomes, Susana R; Rodrigues, Gabriela; Ferreira, Luís M

    2017-02-01

    In the last decade, new generations of biopolymer-based materials have attracted attention, aiming its application as scaffolds for tissue engineering. These engineered three-dimensional scaffolds are designed to improve or replace damaged, missing, or otherwise compromised tissues or organs. Despite the number of promising methods that can be used to generate 3D cell-instructive matrices, the innovative nature of the present work relies on the application of ionizing radiation technology to form and modify surfaces and matrices with advantage over more conventional technologies (room temperature reaction, absence of harmful initiators or solvents, high penetration through the bulk materials, etc.), and the possibility of preparation and sterilization in one single step. The current chapter summarizes the work done by the authors in the gamma radiation processing of biocompatible and biodegradable chitosan-based matrices for skin regeneration. Particular attention is given to the correlation between the different preparation conditions and the final polymeric matrices' properties. We therefore expect to demonstrate that instructive matrices produced and improved by radiation technology bring to the field of skin regenerative medicine a supplemental advantage over more conservative techniques.

  6. Enhancing Food Processing by Pulsed and High Voltage Electric Fields: Principles and Applications.

    PubMed

    Wang, Qijun; Li, Yifei; Sun, Da-Wen; Zhu, Zhiwei

    2018-02-02

    Improvements in living standards result in a growing demand for food with high quality attributes including freshness, nutrition and safety. However, current industrial processing methods rely on traditional thermal and chemical methods, such as sterilization and solvent extraction, which could induce negative effects on food quality and safety. The electric fields (EFs) involving pulsed electric fields (PEFs) and high voltage electric fields (HVEFs) have been studied and developed for assisting and enhancing various food processes. In this review, the principles and applications of pulsed and high voltage electric fields are described in details for a range of food processes, including microbial inactivation, component extraction, and winemaking, thawing and drying, freezing and enzymatic inactivation. Moreover, the advantages and limitations of electric field related technologies are discussed to foresee future developments in the food industry. This review demonstrates that electric field technology has a great potential to enhance food processing by supplementing or replacing the conventional methods employed in different food manufacturing processes. Successful industrial applications of electric field treatments have been achieved in some areas such as microbial inactivation and extraction. However, investigations of HVEFs are still in an early stage and translating the technology into industrial applications need further research efforts.

  7. The Efficacy of Ultraviolet Radiation for Sterilizing Tools Used for Surgically Implanting Transmitters into Fish

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Ricardo W.; Markillie, Lye Meng; Colotelo, Alison HA

    Telemetry is frequently used to examine the behavior of fish, and the transmitters used are normally surgically implanted into the coelom of fish. Implantation requires the use of surgical tools such as scalpels, forceps, needle holders, and sutures. When several fish are implanted consecutively for large telemetry studies, it is common for surgical tools to be sterilized or, at minimum, disinfected between each use so that pathogens that may be present are not spread among fish. However, autoclaving tools can take a long period of time, and chemical sterilants or disinfectants can be harmful to both humans and fish andmore » have varied effectiveness. Ultraviolet (UV) radiation is commonly used to disinfect water in aquaculture facilities. However, this technology has not been widely used to sterilize tools for surgical implantation of transmitters in fish. To determine its efficacy for this application, Pacific Northwest National Laboratory researchers used UV radiation to disinfect surgical tools (i.e., forceps, needle holder, stab scalpel, and suture) that were exposed to one of four aquatic organisms that typically lead to negative health issues for salmonids. These organisms included Aeromonas salmonicida, Flavobacterium psychrophilum, Renibacterium salmoninarum, and Saprolegnia parasitica. Surgical tools were exposed to the bacteria by dipping them into a confluent suspension of three varying concentrations (i.e., low, medium, high). After exposure to the bacterial culture, tools were placed into a mobile Millipore UV sterilization apparatus. The tools were then exposed for three different time periods—2, 5, or 15 min. S. parasitica, a water mold, was tested using an agar plate method and forceps-pinch method. UV light exposures of 5 and 15 min were effective at killing all four organisms. UV light was also effective at killing Geobacillus stearothermophilus, the organism used as a biological indicator to verify effectiveness of steam sterilizers. These techniques appear to provide a quick alternative disinfection technique for some surgical tools that is less harmful to both humans and fish while not producing chemical waste. However, we do not recommend using these methods with tools that have overlapping parts or other structures that cannot be directly exposed to UV light such as needle holders.« less

  8. Mass extraction container closure integrity physical testing method development for parenteral container closure systems.

    PubMed

    Yoon, Seung-Yil; Sagi, Hemi; Goldhammer, Craig; Li, Lei

    2012-01-01

    Container closure integrity (CCI) is a critical factor to ensure that product sterility is maintained over its entire shelf life. Assuring the CCI during container closure (C/C) system qualification, routine manufacturing and stability is important. FDA guidance also encourages industry to develop a CCI physical testing method in lieu of sterility testing in a stability program. A mass extraction system has been developed to check CCI for a variety of container closure systems such as vials, syringes, and cartridges. Various types of defects (e.g., glass micropipette, laser drill, wire) were created and used to demonstrate a detection limit. Leakage, detected as mass flow in this study, changes as a function of defect length and diameter. Therefore, the morphology of defects has been examined in detail with fluid theories. This study demonstrated that a mass extraction system was able to distinguish between intact samples and samples with 2 μm defects reliably when the defect was exposed to air, water, placebo, or drug product (3 mg/mL concentration) solution. Also, it has been verified that the method was robust, and capable of determining the acceptance limit using 3σ for syringes and 6σ for vials. Sterile products must maintain their sterility over their entire shelf life. Container closure systems such as those found in syringes and vials provide a seal between rubber and glass containers. This seal must be ensured to maintain product sterility. A mass extraction system has been developed to check container closure integrity for a variety of container closure systems such as vials, syringes, and cartridges. In order to demonstrate the method's capability, various types of defects (e.g., glass micropipette, laser drill, wire) were created in syringes and vials and were tested. This study demonstrated that a mass extraction system was able to distinguish between intact samples and samples with 2 μm defects reliably when the defect was exposed to air, water, placebo, or drug product (3 mg/mL concentration) solution. Also, it was verified that the method showed consistent results, and was able to determine the acceptance limit using 3σ for syringes and 6σ for vials.

  9. Management of long-term and reversible hysteroscopic sterilization: a novel device with nickel-titanium shape memory alloy

    PubMed Central

    2014-01-01

    Background Female sterilization is the second most commonly used method of contraception in the United States. Female sterilization can now be performed through laparoscopic, abdominal, or hysteroscopic approaches. The hysteroscopic sterilization may be a safer option than sterilization through laparoscopy or laparotomy because it avoids invading the abdominal cavity and undergoing general anaesthesia. Hysteroscopic sterilization mainly includes chemical agents and mechanical devices. Common issues related to the toxicity of the chemical agents used have raised concerns regarding this kind of contraception. The difficulty of the transcervical insertion of such mechanical devices into the fallopian tubes has increased the high incidence of device displacement or dislodgment. At present, Essure® is the only commercially available hysteroscopic sterilization device being used clinically. The system is irreversible and is not effective immediately. Presentation of the hypothesis Our new hysteroscopic sterility system consists of nickel-titanium (NiTi) shape memory alloy and a waterproof membrane. The NiTi alloy is covered with two coatings to avoid toxic Ni release and to prevent stimulation of epithelial tissue growth around the oviducts. Because of the shape memory effect of the NiTi alloy, the device works like an umbrella: it stays collapsed at low temperature before placement and opens by the force of shape memory activated by the body temperature after it is inserted hysteroscopically into the interstitial tubal lumen. The rim of the open device will incise into interstitial myometrium during the process of unfolding. Once the device is fixed, it blocks the tube completely. When the patient no longer wishes for sterilization, the device can be closed by perfusing liquid with low temperature into the uterine cavity, followed by prospective hysteroscopic removal. After the device removal, the fallopian tube will revert to its physiological functions. Testing the hypothesis Currently, experimental and clinical studies are needed to attest the safety, efficiency and reversibility of the novel sterilization device. Implications of the hypothesis If our hypothesis is confirmed, appropriate and reversible contraceptive can be achieved with the device we have designed, which may have significant repercussions for numerous women worldwide. PMID:24999021

  10. Metabolite profiling of non-sterile rhizosphere soil.

    PubMed

    Pétriacq, Pierre; Williams, Alex; Cotton, Anne; McFarlane, Alexander E; Rolfe, Stephen A; Ton, Jurriaan

    2017-10-01

    Rhizosphere chemistry is the sum of root exudation chemicals, their breakdown products and the microbial products of soil-derived chemicals. To date, most studies about root exudation chemistry are based on sterile cultivation systems, which limits the discovery of microbial breakdown products that act as semiochemicals and shape microbial rhizosphere communities. Here, we present a method for untargeted metabolic profiling of non-sterile rhizosphere soil. We have developed an experimental growth system that enables the collection and analysis of rhizosphere chemicals from different plant species. High-throughput sequencing of 16SrRNA genes demonstrated that plants in the growth system support a microbial rhizosphere effect. To collect a range of (a)polar chemicals from the system, we developed extraction methods that do not cause detectable damage to root cells or soil-inhabiting microbes, thus preventing contamination with cellular metabolites. Untargeted metabolite profiling by UPLC-Q-TOF mass spectrometry, followed by uni- and multivariate statistical analyses, identified a wide range of secondary metabolites that are enriched in plant-containing soil, compared with control soil without roots. We show that the method is suitable for profiling the rhizosphere chemistry of Zea mays (maize) in agricultural soil, thereby demonstrating the applicability to different plant-soil combinations. Our study provides a robust method for the comprehensive metabolite profiling of non-sterile rhizosphere soil, which represents a technical advance towards the establishment of causal relationships between the chemistry and microbial composition of the rhizosphere. © 2017 The Authors The Plant Journal published by John Wiley & Sons Ltd and Society for Experimental Biology.

  11. Bolstering Skin Grafts With a Surgical Scrub Brush: A Cost-effective Solution.

    PubMed

    Buller, Mitchell; Lee, Thomas J; Davis, Jared; Wilhelmi, Bradon J

    2017-01-01

    Objective: The objective of this article is to review the methods currently used for the bolstering of skin grafts and compare their advantages and disadvantages with those of the dry, sterile surgical scrub brush. We report a series of cases performed at a single institution and compare the cost-effectiveness, application, and limitations of this method with other options for skin graft bolstering. Methods: A PubMed search using the parameters "(bolster) AND skin graft" was conducted, yielding 85 results. A total of 40 publications met the criteria for our literature review. The costs of the foam bolsters utilized as stents for skin grafts were obtained from the Central Supply and Resource Division of the University of Louisville Hospital for a cost analysis. The cost per square centimeter of each bolster material was calculated. Results: At $0.003/cm 2 , the 3M Reston foam is the most inexpensive of the 3 bolster materials analyzed. The dry, sterile surgical scrub brush has a similar cost at $0.006/cm 2 but carries the advantage of sterility. The material cost of negative pressure wound therapy is $0.47/cm 2 , and the cost of the system as a whole makes it a much more expensive alternative. In 6 patients with defects of varying size and location, the scrub brush bolster showed a near 100% graft take and no complications. Conclusions: The dry, sterile surgical scrub brush presents a readily available and low-cost option for the stenting of small skin grafts and should be considered a viable method in the armamentarium of available skin graft bolsters.

  12. Applicability of bacterial cellulose as an alternative to paper points in endodontic treatment.

    PubMed

    Yoshino, Aya; Tabuchi, Mari; Uo, Motohiro; Tatsumi, Hiroto; Hideshima, Katsumi; Kondo, Seiji; Sekine, Joji

    2013-04-01

    Dental root canal treatment is required when dental caries progress to infection of the dental pulp. A major goal of this treatment is to provide complete decontamination of the dental root canal system. However, the morphology of dental root canal systems is complex, and many human dental roots have inaccessible areas. In addition, dental reinfection is fairly common. In conventional treatment, a cotton pellet and paper point made from plant cellulose is used to dry and sterilize the dental root canal. Such sterilization requires a treatment material with high absorbency to remove any residue, the ability to improve the efficacy of intracanal medication and high biocompatibility. Bacterial cellulose (BC) is produced by certain strains of bacteria. In this study, we developed BC in a pointed form and evaluated its applicability as a novel material for dental canal treatment with regard to solution absorption, expansion, tensile strength, drug release and biocompatibility. We found that BC has excellent material and biological characteristics compared with conventional materials, such as paper points (plant cellulose). BC showed noticeably higher absorption and expansion than paper points, and maintained a high tensile strength even when wet. The cumulative release of a model drug was significantly greater from BC than from paper points, and BC showed greater compatibility than paper points. Taken together, BC has great potential for use in dental root canal treatment. Copyright © 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  13. A novel alphavirus replicon-vectored vaccine delivered by adenovirus induces sterile immunity against classical swine fever.

    PubMed

    Sun, Yuan; Li, Hong-Yu; Tian, Da-Yong; Han, Qiu-Ying; Zhang, Xin; Li, Na; Qiu, Hua-Ji

    2011-10-26

    Low efficacy of gene-based vaccines due to inefficient gene delivery and expression has been major bottleneck of their applications. Efforts have been made to improve the efficacy, such as gene gun and electroporation, but the strategies are difficult to put into practical use. In this study, we developed and evaluated an adenovirus-delivered, alphavirus replicon-vectored vaccine (chimeric vector-based vaccine) expressing the E2 gene of classical swine fever virus (CSFV) (rAdV-SFV-E2). Rabbits immunized with rAdV-SFV-E2 developed CSFV-specific antibodies as early as 9 days and as long as 189 days and completely protected from challenge with C-strain. Pigs immunized with rAdV-SFV-E2 (n=5) developed robust humoral and cell-mediated responses to CSFV and were completely protected from subsequent lethal CSFV infection clinically and virologically. The level of immunity and protection induced by rAdV-SFV-E2 was comparable to that provided by the currently used live attenuated vaccine, C-strain. In contrast, both the conventional alphavirus replicon-vectored vaccine pSFV1CS-E2 and conventional adenovirus-vectored vaccine rAdV-E2 provided incomplete protection. The chimeric vector-based vaccine represents the first gene-based vaccine that is able to confer sterile immunity and complete protection against CSFV. The new-concept vaccination strategy may also be valuable in vaccine development against other pathogens. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strauss, Steve; Shevchenko, Olga; Ma, Caiping

    The overall goal of this project was to develop and validate sterility systems in poplar with the ultimate goal of fulfilling the basic requirements for commercial use. For this, sterility must be complete and stable over multiple growing seasons, cause no detrimental effects on vegetative growth, and successful transformation events must be identifiable via molecular tests when trees are still juvenile. Because of the inherent difficulties in achieving and demonstrating complete sterility in trees, our approach was to study alternate sterility systems in Arabidopsis and/or early-flowering tree systems. The public benefit from this work is the capacity for containment ofmore » genes or exotic forms of trees so they can be of benefit for industry for production of wood, energy, and renewable products, while having minimal impact on wild populations of trees. We tested three methods for engineering sterility: dominant negative mutant (DNM) proteins, floral tissue ablation, and RNA interference (RNAi) to suppress the expression of several floral regulatory genes. The ultimate goal of this work was to produce a number of transgenic poplars that could be outplanted to enable future assessments of the effectiveness of these transgenic sterility methods. Our attempts to produce ablation constructs that did not interfere with tree health were partially successful. Using the poplar LEAFY gene promoter and the barnase/barstar system, we were able to regenerate plants that grew well in the greenhouse, but they showed poor health in the field. Four of seven DNM genes tested were considered promising enough, based on results in Arabidopsis, to produce transgenic poplars. Single, double, and triple RNAi genes were produced and transformed into poplar. Over all, we produced 1,964 PCR-confirmed transgenic events with 19 different kinds of sterility genes and several kinds of control genes. We propagated 5,640, 6,820, and 7,055 trees for each of three test poplar genotypes, and field plantings were begun in Spring of 2003 and will be finished in Spring 2007. Continued field studies and monitoring will be required to establish if any of the approaches we have taken will prove to be safe for tree health, stable, and provide reliable containment.« less

  15. Cleaning and disinfection of patient care items, in relation to small animals.

    PubMed

    Weese, J Scott

    2015-03-01

    Patient care involves several medical and surgical items, including those that come into contact with sterile or other high-risk body sites and items that have been used on other patients. These situations create a risk for infection if items are contaminated, and the implications can range from single infections to large outbreaks. To minimize the risk, proper equipment cleaning, disinfection/sterilization, storage, and monitoring practices are required. Risks posed by different items; the required level of cleaning, disinfection, or sterilization; the methods that are available and appropriate; and how to ensure efficacy, must be considered when designing and implementing an infection control program. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Sterilization of rural and urban women in the United States.

    PubMed

    Lunde, Britt; Rankin, Kristin; Harwood, Bryna; Chavez, Noel

    2013-08-01

    To examine the prevalence of sterilization among women aged 20-34 years in rural and urban areas in the United States. Data were obtained from the 2006-2010 National Survey of Family Growth, a cross-sectional survey conducted by the Centers for Disease Control and Prevention. The study population included the 4,685 female respondents who did not want to become pregnant at the time of the survey. Women who were not sexually active with men or were infertile for reasons other than contraception were excluded. We performed bivariate and stratified analysis and multivariable logistic regression modeling to determine the associations between place of residence and sterilization after considering other demographic characteristics. Rural women were at increased odds of undergoing sterilization compared with urban and suburban women (22.75% compared with 12.69%, respectively; crude odds ratio [OR] 2.03, 95% confidence interval [CI] 1.44-2.86; risk difference 0.10, 95% CI 0.05-0.16). Education level was found to be a significant effect modifier of the relationship between location of residence and sterilization. In adjusted analysis, controlling for age, parity, race and ethnicity, income, insurance status, history of unintended pregnancy, and relationship status, rural women without a high school degree were more likely to have undergone sterilization compared with urban and rural women with greater than a high school education (OR 8.34, 95% CI 4.45-15.61). Rural women with low education levels have a high prevalence of sterilization. Future studies need to address the reasons for this interaction between education and geography and its influence on contraceptive method choice. II.

  17. Sterilization of allograft bone: is 25 kGy the gold standard for gamma irradiation?

    PubMed

    Nguyen, Huynh; Morgan, David A F; Forwood, Mark R

    2007-01-01

    For several decades, a dose of 25 kGy of gamma irradiation has been recommended for terminal sterilization of medical products, including bone allografts. Practically, the application of a given gamma dose varies from tissue bank to tissue bank. While many banks use 25 kGy, some have adopted a higher dose, while some choose lower doses, and others do not use irradiation for terminal sterilization. A revolution in quality control in the tissue banking industry has occurred in line with development of quality assurance standards. These have resulted in significant reductions in the risk of contamination by microorganisms of final graft products. In light of these developments, there is sufficient rationale to re-establish a new standard dose, sufficient enough to sterilize allograft bone, while minimizing the adverse effects of gamma radiation on tissue properties. Using valid modifications, several authors have applied ISO standards to establish a radiation dose for bone allografts that is specific to systems employed in bone banking. These standards, and their verification, suggest that the actual dose could be significantly reduced from 25 kGy, while maintaining a valid sterility assurance level (SAL) of 10(-6). The current paper reviews the methods that have been used to develop radiation doses for terminal sterilization of medical products, and the current trend for selection of a specific dose for tissue banks.

  18. In vitro sterilization technique on embryo of black Toraja rice

    NASA Astrophysics Data System (ADS)

    Haring, F.; Riadi, M.; Rafiuddin; Sjahril, R.; Muchlis, A. R.

    2018-05-01

    Toraja black rice has a high anthocyanin content, a water-soluble pigments, with antioxidant activity. Toraja black rice has a variety of seeds colour in one panicles such as full black (the outside and inside the rice), medium black (the outside and slightly inside rice) and a little black (only the outside of rice). Embryo culture in vitro is one way to grow plants in sterile conditions. The presence of contamination and the death of the embryo require in vitro embryo culture. The sterilization technique is a very important first step to eliminate contamination and the death of embryos. This research aims to determine the right material composition for sterilization of black rice’s embryo. The experiment was done by growing black rice on half strength MS media with the treatment of three method of sterilization, i.e.: S1 (70% alcohol for 5 minutes, 3% and 2% Chlorox each for 10 minutes,), S2 (70% alcohol for 3 minutes, 2% Clorox for 10 minutes) and S3 (70% alcohol for 3 minutes and 1% Clorox for 15 minutes). The materials used are rice seedlings that have been cut in two and opened the pericarp of paddy grain, leaving a piece of rice that has a complete embryo. The best sterilization for Toraja black rice embryo culture was using the S3 composition. Best germination was seen on the seeds with full and medium black color.

  19. Effect of different sterilization modes on the surface morphology, ion release, and bone reaction of retrieved micro-implants.

    PubMed

    El-Wassefy, Noha; El-Fallal, Abeer; Taha, Mahasen

    2015-01-01

    To compare as-received and sterilized micro-implants in order to assess the prospects of reusing them. Forty micro-implants from a single manufacturing lot were used in the study. Thirty were retrieved from patients after successful service in their mouth and with no signs of failure. The retrieved micro-implants were divided into three groups, according to method of sterilization: autoclave, gamma radiation, or ultraviolet radiation. All groups were subjected to scanning electron microscope analysis for surface morphology assessment. The specimens were immersed in a standard simulated body-fluid solution kept at 37°C in an incubator; the solution was then withdrawn at 24 hours and 30 days to evaluate aluminum and vanadium ion release by atomic absorption spectrophotometer in parts per billion. The micro-implants were then surgically implanted into the tibia of rabbits for a 1-month healing period, and the bone-implant blocks were processed for routine histologic examination. This study revealed that sterilized micro-implants had altered surface topography, different ion release values, and different histologic cell reactions than the as-received micro-implants. Within the limitations of this study, it can be concluded that retrieved self-drilling micro-implants have tip sharpness variations that require correction before insertion by bone drilling. The autoclave-sterilized micro-implants showed better histologic results than micro-implants sterilized by gamma or ultraviolet rays.

  20. Cytological characterization of a thermo-sensitive cytoplasmic male-sterile wheat line having K-type cytoplasm of Aegilops kotschyi

    PubMed Central

    Meng, Liying; Liu, Zihan; Zhang, Lingli; Hu, Gan; Song, Xiyue

    2016-01-01

    Male sterility is an important tool for obtaining crop heterosis. A thermo-sensitive cytoplasmic male-sterile (TCMS) line was developed recently using a new method based on tiller regeneration. In the present study, we explored the critical growth stages required to maintain thermo-sensitive male sterility in TCMS lines and found that fertility is associated with abnormal tapetal and microspore development. We investigated the fertility and cytology of temperature-treated plant anthers at various developmental stages. TCMS line KTM3315A exhibited thermo-sensitive male sterility in Zadoks growth stages 41–49 and 58–59. Morphologically, the line exhibited thermo-sensitive male sterility at 3–9 days before heading and at 3–6 days before flowering, and it was partially restored in three locations during spring and summer. TCMS line KTM3315A plants exhibited premature tapetal programmed cell death (PCD) from the early uninucleate stage of microspore development until the tapetal cells degraded completely. Microspore development was then blocked and the pollen abortion type was stainable abortion. Thus, male fertility in the line KTM3315A is sensitive to temperature and premature tapetal PCD is the main cause of pollen abortion, where it determines the starting period and affects male fertility conversion in K-type TCMS lines at certain temperatures. PMID:28163591

  1. Aseptic laboratory techniques: plating methods.

    PubMed

    Sanders, Erin R

    2012-05-11

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: Perform plating procedures without contaminating media. Isolate single bacterial colonies by the streak-plating method. Use pour-plating and spread-plating methods to determine the concentration of bacteria. Perform soft agar overlays when working with phage. Transfer bacterial cells from one plate to another using the replica-plating procedure. Given an experimental task, select the appropriate plating method.

  2. Effectiveness of Family Planning Methods

    MedlinePlus

    ... women in a year Effectiveness of Family Planning Methods Implant Reversible Intrauterine Device (IUD) Permanent Male Sterilization ... 0.5 % Diaphragm 12 % How to make your method most effective After procedure, little or nothing to ...

  3. Preliminary thermoluminescence investigation of commercial pharmaceutical glass containers towards the sterilization dosimetry of liquid drugs.

    PubMed

    Kazakis, Nikolaos A; Tsirliganis, Nestor C; Kitis, George

    2015-11-01

    Drug sterilization with ionizing radiation is a well-established technology, which is constantly extending to several products due to its numerous advantages, since it allows the heat-free sterilization of heat-sensitive pharmaceutical preparations. In a previous study, the possibility to identify irradiated solid-state drugs by means of OSL and TL was examined with very promising findings. In the same respect, the present work aims, for the first time to the authors' best knowledge, to explore whether TL can be employed as a method for post-sterilization dosimetry on commercial liquid-state drugs, by studying the properties of their glass containers. Two different types of glass containers (bottle and ampoule) of two widely used liquid drugs, i.e., Hexalen® and Voltaren®, are used for this purpose. Both glass containers exhibit a linear TL dose response for doses up to 6kGy with a stable behavior through time, while no significant sensitization of the main peaks is observed. Thus, preliminary findings are very promising towards the post-sterilization dosimetry of liquid drugs and the use of the containers of commercial liquid drugs for normal and/or accidental dosimetry. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Risk of Contamination in Assembled vs Disassembled Instruments in Hip Arthroplasty Surgery

    PubMed Central

    Mayer, Ryan R.; Bederman, S. Samuel; Colin, Vincent M.; Berger, Martina M.; Cesario, Thomas C.; Schwarzkopf, Ran

    2018-01-01

    Background Periprosthetic joint infection (PJI) is one of the most common causes of revision total hip arthroplasty (THA) and associated with higher costs, prolonged pain, and worse clinical outcomes. Many factors have been linked to increased infection rates, one being the operative equipment and instrumentation used during the surgical procedure. With few arthroplasty instruments designed for complete disassembly and increasingly complex instrument designs, this study seeks to understand the effect that instrument disassembly plays on infection using disassembled and assembled standard femoral broach handles (BHs). Methods Two BHs, not designed for disassembly, were modified and then contaminated in the disassembled state with Geobacillus stearothermophilus vegetative-form bacteria and spores. Using both flash and standard sterilization cycles, the BHs were steam sterilized in the disassembled or assembled state and then analyzed for remaining bacteria and spores. Results At all target locations after either a flash sterilization cycle or a standard sterilization cycle, complete eradication of both the vegetative-form and spore-form of G stearothermophilus was achieved. Conclusion This study demonstrates that adequate decontamination of the tested BHs can be achieved after steam sterilization in either the disassembled or assembled state, without an increased risk of infection transmission. PMID:26948131

  5. Nano drug delivery systems and gamma radiation sterilization.

    PubMed

    Sakar, F; Özer, A Y; Erdogan, S; Ekizoglu, M; Kart, D; Özalp, M; Colak, S; Zencir, Y

    2017-09-01

    In recent years, drug delivery systems such as liposomes and microparticles have been used in clinic for the treatment of different diseases and from a regulatory point of view, a parenterally applied drug and drug delivery systems must be sterile and pyrogen free. Radiation sterilization is a method recognized by pharmacopoeias to achieve sterility criteria of parenterals. It has the ability to kill microorganisms in therapeutic products. The ability of, however, irradiation might also affect the performance of drug delivery systems. One of the most critical points is irradiation dose, because certain undesirable chemical and physical changes may accompany with the irradiation, especially with the traditionally applied dose of 25 kGy. Its ionizing property may cause fragmentation of covalent bond. The care must be paid to the applied dose. In this research, the effects of gamma irradiation on different drug delivery systems such as chitosan microparticles, liposomes, niosomes and sphingosomes were investigated. According to the experimental data, it can be concluded that gamma irradiation can be a suitable sterilization technique for liposome, niosome and sphingosome dispersions. When all irradiated drug carrier systems were taken into consideration, chitosan glutamate microparticles were found as the most radioresistant drug delivery system among the others.

  6. Sterilization of Microorganisms by Ozone and Ultrasound

    NASA Astrophysics Data System (ADS)

    Krasnyj, V. V.; Klosovskij, A. V.; Panasko, T. A.; Shvets, O. M.; Semenova, O. T.; Taran, V. S.; Tereshin, V. I.

    2008-03-01

    The results of recent experimental methods of sterilization of microorganisms with the use of ozone and ultrasound are presented. The main aim was to optimize the process of sterilization in water solution taking into account the ozone concentration, the power of ultrasonic emitter and the temperature of water. In the present work, the ultrasonic cavitation with simultaneous ozone generation has been used. The high ozone concentration in water solution was achieved by two-barrier glow discharge generated at atmospheric pressure and a cooling thermo-electric module. Such a sterilizer consists of ozone generator in a shape of flat electrodes covered with dielectric material and a high-voltage pulsed power supply of 250 W. The sterilization camera was equipped with ultrasonic source operated at 100 W. The experiments on the inactivation of bacteria of the Bacillus Cereus type were carried out in the distilled water saturated by ozone. The ozone concentration in the aqueous solution was 10 mg/1, whereas the ozone concentration at the output of ozone generator was 30 mg/1. The complete inactivation of spores took 15 min. Selection of the temperature of water, the ozone concentrations and ultrasonic power allowed to determine the time necessary for destroying the row of microorganisms.

  7. Autoclave Sterilization of PEDOT:PSS Electrophysiology Devices.

    PubMed

    Uguz, Ilke; Ganji, Mehran; Hama, Adel; Tanaka, Atsunori; Inal, Sahika; Youssef, Ahmed; Owens, Roisin M; Quilichini, Pascale P; Ghestem, Antoine; Bernard, Christophe; Dayeh, Shadi A; Malliaras, George G

    2016-12-01

    Autoclaving, the most widely available sterilization method, is applied to poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate (PEDOT:PSS) electrophysiology devices. The process does not harm morphology or electrical properties, while it effectively kills E. coli intentionally cultured on the devices. This finding paves the way to widespread introduction of PEDOT:PSS electrophysiology devices to the clinic. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Search for neutrino transitions to sterile states using an intense beta source

    NASA Astrophysics Data System (ADS)

    Oralbaev, A. Yu.; Skorokhvatov, M. D.; Titov, O. A.

    2017-11-01

    The results of beta spectrum calculations for two 144Pr decay branches are presented, which are of interest for reconstructing the spectrum of antineutrinos from the 144Ce-144Pr source to be used in the SOX experiment on the search for sterile neutrinos. The main factors affecting the beta spectrum are analyzed, their calculation methods are given, and calculations are compared with experiment.

  9. A Risk-Based Approach to Variable Load Configuration Validation in Steam Sterilization: Application of PDA Technical Report 1 Load Equivalence Topic.

    PubMed

    Pavell, Anthony; Hughes, Keith A

    2010-01-01

    This article describes a method for achieving the load equivalence model, described in Parenteral Drug Association Technical Report 1, using a mass-based approach. The item and load bracketing approach allows for mixed equipment load size variation for operational flexibility along with decreased time to introduce new items to the operation. The article discusses the utilization of approximately 67 items/components (Table IV) identified for routine sterilization with varying quantities required weekly. The items were assessed for worst-case identification using four temperature-related criteria. The criteria were used to provide a data-based identification of worst-case items, and/or item equivalence, to carry forward into cycle validation using a variable load pattern. The mass approach to maximum load determination was used to bracket routine production use and allows for variable loading patterns. The result of the item mapping and load bracketing data is "a proven acceptable range" of sterilizing conditions including loading configuration and location. The application of these approaches, while initially more time/test-intensive than alternate approaches, provides a method of cycle validation with long-term benefit of ease of ongoing qualification, minimizing time and requirements for new equipment qualification for similar loads/use, and for rapid and rigorous assessment of new items for sterilization.

  10. Reformulating Polycaprolactone Fumarate to Eliminate Toxic Diethylene Glycol: Effects of Polymeric Branching and Autoclave Sterilization on Material Properties

    PubMed Central

    Runge, M. Brett; Wang, Huan; Spinner, Robert J; Windebank, Anthony J; Yaszemski, Michael J.

    2011-01-01

    Polycaprolactone fumarate (PCLF) is a cross-linkable derivate of polycaprolactone diol that has been shown to be an effective nerve conduit material that supports regeneration across segmental nerve defects and has warranted future clinical trials. Degradation of the previously studied PCLF (PCLFDEG) releases toxic small molecules of diethylene glycol used as the initiator for the synthesis of polycaprolactone diol. In an effort to eliminate this toxic degradation product we present a strategy for the synthesis of PCLF from either propylene glycol (PCLFPPD) or glycerol (PCLFGLY). PCLFPPD is linear and resembles the previously studied PCLFDEG, while PCLFGLY is branched and exhibits dramatically different material properties. The synthesis and characterization of their thermal, rheological, and mechanical properties are reported. The results show that the linear PCLFPPD has material properties similar to the previously studied PCLFDEG. The branched PCLFGLY exhibits dramatically lower crystalline properties resulting in lower rheological and mechanical moduli, and is therefore a more compliant material. In addition, the question of an appropriate FDA approvable sterilization method is addressed. This study shows that autoclave sterilization on PCLF materials is an acceptable sterilization method for cross-linked PCLF and has minimal effect on the PCLF thermal and mechanical properties. PMID:21911087

  11. Electron Beam Sterilization Does Not Have a Detrimental Effect on the Ability of Extracellular Matrix Scaffolds to Support In Vivo Ligament Healing

    PubMed Central

    Proffen, Benedikt L.; Perrone, Gabriel S.; Fleming, Braden C.; Sieker, Jakob T.; Kramer, Joshua; Hawes, Michael L.; Badger, Gary J.; Murray, Martha M.

    2015-01-01

    Purpose Extra-cellular matrix (ECM) scaffolds have been used to enhance anterior cruciate ligament (ACL) repair in large animal models. To translate this technology to clinical care, identifying a method, which effectively sterilizes the material without significantly impairing in vivo function, is desirable. Methods 16 Yorkshire pigs underwent ACL transection and were randomly assigned to bridge-enhanced ACL repair – primary suture repair of the ACL with addition of autologous blood soaked ECM scaffold - with either 1) an aseptically processed ECM scaffold, or 2) an electron beam irradiated ECM scaffold. Primary outcome measures included sterility of the scaffold and biomechanical properties of the scaffold itself and the repaired ligament at eight weeks after surgery. Results Scaffolds treated with 15kGy electron beam irradiation had no bacterial or fungal growth noted, while aseptically processed scaffolds had bacterial growth in all tested samples. The mean biomechanical properties of the scaffold and healing ligament were lower in the electron beam group; however, differences were not statistically significant. Conclusions Electron beam irradiation was able to effectively sterilize the scaffolds. In addition, this technique had only a minimal impact on the in vivo function of the scaffolds when used for ligament healing in the porcine model. PMID:25676876

  12. Distribution of Malassezia species in patients with pityriasis versicolor in Turkey.

    PubMed

    Rodoplu, G; Saracli, M A; Gümral, R; Taner Yildiran, S

    2014-06-01

    Pityriasis versicolor is a common superficial mycotic disease of the skin which is caused by different species of Malassezia genus. The aim of this study was to contribute to the knowledge of the aetiology of pityriasis versicolor (PV) with a mycological study made according to the new species and additionally, the success of the different sampling techniques, duration and recurrence history of the disease, distribution of infecting strains according to the affected body sites were also investigated. In total, 146 patients with pityriasis versicolor were included in this study. Fungal elements could only be visualized by potassium hydroxide examination in 36.4% of the samples. Specimens obtained by scraping skin surface by a sterile scalpel and/or sterile sticky plaster (OpSite) were inoculated in plates containing modified Dixon's medium. Out of 146 samples, 109 (74.7%) yielded a growth which was considered to be Malassezia spp. in culture. Species level identification of suspicious Malassezia yeasts was made according to their macroscopic and microscopic features, and their physiological characteristics. Among the identified species, Malassezia globosa (65.1%) was the most commonly isolated species, followed by Malassezia obtusa (17.4%). However, four Malassezia isolates could not be identified at species level with conventional methods. While most of the patients suffered their first episode of pityriasis versicolor (76%), back of the trunk was the mostly affected body site (39%). In conclusion, Malassezia globosa was found to be the predominant species in pityriasis versicolor patients in our region, and culture of the specimen is necessary for the epidemiologic purposes. Copyright © 2014. Published by Elsevier Masson SAS.

  13. Majorana vs. Dirac sterile neutrinos lighter than MW at the LHC

    NASA Astrophysics Data System (ADS)

    Dib, C. O.; Kim, C. S.; Wang, K.; Zhang, J.

    2017-09-01

    We propose to study the leptonic decays W± → e±e±µ ∓ ν and W± → µ±µ±e ∓ ν at the LHC to discover sterile neutrinos with masses below MW , and discriminate their Majorana or Dirac character. These decays are induced by a sterile neutrino N that goes on mass shell in the intermediate state. We find that, even though the final (anti-)neutrino goes undetected and thus lepton number is unchecked, one can distinguish between the Majorana vs. Dirac character of the intermediate sterile neutrino by comparing the production of e±e±µ ∓ vs. µ±µ±e ∓, provided the N-e and N-µ mixings are different enough. Alternatively, one can also distinguish the Majorana vs. Dirac character by studying the energy spectra of the opposite charge lepton, a method that works even if the N-e and N-µ mixings are equal.

  14. EFFECTS OF CHEMICAL PROCESSING AND OXIDE ETHYLENE STERILIZATION ON CORTICAL AND CANCELLOUS RAT BONE: A LIGHT AND ELECTRON SCANNING MICROSCOPY STUDY

    PubMed Central

    Castiglia, Marcello Teixeira; da Silva, Juliano Voltarelli F.; Frezarim Thomazini, José Armendir; Volpon, José Batista

    2015-01-01

    To evaluate, under microscopic examination, the structural changes displayed by the trabecular and cortical bones after being processed chemically and sterilized by ethylene oxide. Methods: Samples of cancellous and cortical bones obtained from young female albinus rats (Wistar) were assigned to four groups according to the type of treatment: Group I- drying; Group II- drying and ethylene oxide sterilization; III- chemical treatment; IV- chemical treatment and ethylene oxide sterilization. Half of this material was analyzed under ordinary light microscope and the other half using scanning electron microscopy. Results: In all the samples, regardless the group, there was good preservation of the general morphology. For samples submitted to the chemical processing there was better preservation of the cellular content, whereas there was amalgamation of the fibres when ethylene oxide was used. Conclusion: Treatment with ethylene oxide caused amalgamation of the fibers, possibly because of heating and the chemical treatment contributed to a better cellular preservation of the osseous structure. PMID:26998450

  15. Ancient microbes from halite fluid inclusions: optimized surface sterilization and DNA extraction.

    PubMed

    Sankaranarayanan, Krithivasan; Timofeeff, Michael N; Spathis, Rita; Lowenstein, Tim K; Lum, J Koji

    2011-01-01

    Fluid inclusions in evaporite minerals (halite, gypsum, etc.) potentially preserve genetic records of microbial diversity and changing environmental conditions of Earth's hydrosphere for nearly one billion years. Here we describe a robust protocol for surface sterilization and retrieval of DNA from fluid inclusions in halite that, unlike previously published methods, guarantees removal of potentially contaminating surface-bound DNA. The protocol involves microscopic visualization of cell structures, deliberate surface contamination followed by surface sterilization with acid and bleach washes, and DNA extraction using Amicon centrifugal filters. Methods were verified on halite crystals of four different ages from Saline Valley, California (modern, 36 ka, 64 ka, and 150 ka), with retrieval of algal and archaeal DNA, and characterization of the algal community using ITS1 sequences. The protocol we developed opens up new avenues for study of ancient microbial ecosystems in fluid inclusions, understanding microbial evolution across geological time, and investigating the antiquity of life on earth and other parts of the solar system.

  16. Principles of Sterilization of Mars Descent Vehicle Elements

    NASA Astrophysics Data System (ADS)

    Trofimov, Vladislav; Deshevaya, Elena; Khamidullina, N.; Kalashnikov, Viktor

    Due to COSPAR severe requirements to permissible microbiological contamination of elements of down-to-Mars S/C as well as complexity of their chemical composition and structure the exposure of such S/C elements to antimicrobial treatment (sterilization) at their integration requires application of a wide set of methods: chemical, ultraviolet, radiation. The report describes the analysis of all the aspects of applicable methods of treatment for cleaning of elements’ surfaces and inner contents from microbiota. The analysis showed that the most important, predictable and controllable method is radiation processing (of the elements which don’t change their properties after effective treatment). The experience of ionizing radiation application for sterilization of products for medicine, etc. shows that, depending on initial microbial contamination of lander elements, the required absorbed dose can be within the range 12 ÷ 35 kGr. The analysis of the effect of irregularity of radiation absorption in complex structure elements to the choice of radiation methodology was made and the algorithm of the choice of effective conditions of radiation treatment and control of sterilization efficiency was suggested. The important phase of establishing of the effective condition of each structure element treatment is experimental verification of real microbiological contamination in terms of S/C integration, contamination maximum decrease using another cleaning procedures (mechanical, chemical, ultraviolet) and determination of radiation resistance of spore microorganisms typical for the shops of space technology manufacturing and assembling. Proceeding from three parameters (irregularity of radiation absorption in a concrete element, its initial microbial contamination and resistance of microorganisms to the effect of radiation) the condition of the packed object sterilization is chosen, the condition that prevents secondary contamination, ensures given reliability of the treatment without final experimental microbiological verification only by simple control of the absorbed dose at critical points. All the process phases (from the choice of treatment conditions to provision of the procedure safety) are strictly regulated by Russian legislation in accordance with international standards.

  17. Improvements in the simulation code of the SOX experiment

    NASA Astrophysics Data System (ADS)

    Caminata, A.; Agostini, M.; Altenmüeller, K.; Appel, S.; Atroshchenko, V.; Bellini, G.; Benziger, J.; Bick, D.; Bonfini, G.; Bravo, D.; Caccianiga, B.; Calaprice, F.; Carlini, M.; Cavalcante, P.; Chepurnov, A.; Choi, K.; Cribier, M.; D'Angelo, D.; Davini, S.; Derbin, A.; Di Noto, L.; Drachnev, I.; Durero, M.; Etenko, A.; Farinon, S.; Fischer, V.; Fomenko, K.; Franco, D.; Gabriele, F.; Gaffiot, J.; Galbiati, C.; Gschwender, M.; Ghiano, C.; Giammarchi, M.; Goeger-Neff, M.; Goretti, A.; Gromov, M.; Hagner, C.; Houdy, Th.; Hungerford, E.; Ianni, Aldo; Ianni, Andrea; Jonquères, N.; Jany, A.; Jedrzejczak, K.; Jeschke, D.; Kobychev, V.; Korablev, D.; Korga, G.; Kornoukhov, V.; Kryn, D.; Lachenmaier, T.; Lasserre, T.; Laubenstein, M.; Lehnert, B.; Link, J.; Litvinovich, E.; Lombardi, F.; Lombardi, P.; Ludhova, L.; Lukyanchenko, G.; Machulin, I.; Manecki, S.; Maneschg, W.; Manuzio, G.; Marcocci, S.; Maricic, J.; Mention, G.; Meroni, E.; Meyer, M.; Miramonti, L.; Misiaszek, M.; Montuschi, M.; Mosteiro, P.; Muratova, V.; Musenich, R.; Neumair, B.; Oberauer, L.; Obolensky, M.; Ortica, F.; Pallavicini, M.; Papp, L.; Pocar, A.; Ranucci, G.; Razeto, A.; Re, A.; Romani, A.; Roncin, R.; Rossi, N.; Schönert, S.; Scola, L.; Semenov, D.; Skorokhvatov, M.; Smirnov, O.; Sotnikov, A.; Sukhotin, S.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Thurn, J.; Toropova, M.; Unzhakov, E.; Veyssiére, C.; Vishneva, A.; Vivier, M.; Vogelaar, R. B.; von Feilitzsch, F.; Wang, H.; Weinz, S.; Winter, J.; Wojcik, M.; Wurm, M.; Yokley, Z.; Zaimidoroga, O.; Zavatarelli, S.; Zuber, K.; Zuzel, G.

    2017-09-01

    The aim of the SOX experiment is to test the hypothesis of existence of light sterile neutrinos trough a short baseline experiment. Electron antineutrinos will be produced by an high activity source and detected in the Borexino experiment. Both an oscillometry approach and a conventional disappearance analysis will be performed and, if combined, SOX will be able to investigate most of the anomaly region at 95% c.l. This paper focuses on the improvements performed on the simulation code and on the techniques (calibrations) used to validate the results.

  18. Comparison of PCR, culturing and Pap smear microscopy for accurate diagnosis of genital Actinomyces.

    PubMed

    Kaya, Dilek; Demirezen, Şayeste; Hasçelik, Gülşen; Gülmez Kivanç, Dolunay; Beksaç, Mehmet Sinan

    2013-05-01

    Members of the genus Actinomyces, Gram-positive, non-spore-forming anaerobic bacteria, are normal inhabitants of the mucosal surfaces of the oral, gastrointestinal and genital tracts. Identification of these bacteria using conventional methods is generally difficult because of their complex transport and growth requirements and their fastidious and slow-growing nature. However, in recent years, the advancement of molecular techniques has provided much improved identification and differentiation of closely related Actinomyces species. The aim of the present study was to evaluate the efficacy of the PCR technique in the diagnosis of genital Actinomyces in comparison with culturing and Papanicolaou (Pap) smear microscopy. Multiple sampling was conducted from 200 women using smear microscopy, culturing and PCR. Cyto-brushes were smeared on glass slides and stained using the routine Pap technique. Culturing was performed from a sterile swab, and Actinomyces were determined using the BBL Crystal ANR ID kit. PCR was performed from a second swab, and the Actinomyces type was determined using type-specific primers designed in our laboratory. Only one vaginal fluid sample (0.5%) revealed Actinomyces-like organisms on Pap smear examination. Actinomyces were detected in nine samples (4.5%) using the BBL Crystal ANR ID kit. Using PCR, eight samples (4%) were found positive for Actinomyces. No specimens that gave positive results by Pap smear microscopy and culturing could be confirmed by PCR. Pap smear microscopy and culturing were both found to have zero sensitivity for Actinomyces. PCR appears to be a sensitive and reliable diagnostic method for the detection of Actinomyces, which are difficult to cultivate from genital samples. PCR can be used for diagnostic confirmation in cases diagnosed by conventional methods, to prevent false-positive results.

  19. Microbial consortia in meat processing environments

    NASA Astrophysics Data System (ADS)

    Alessandria, V.; Rantsiou, K.; Cavallero, M. C.; Riva, S.; Cocolin, L.

    2017-09-01

    Microbial contamination in food processing plants can play a fundamental role in food quality and safety. The description of the microbial consortia in the meat processing environment is important since it is a first step in understanding possible routes of product contamination. Furthermore, it may contribute in the development of sanitation programs for effective pathogen removal. The purpose of this study was to characterize the type of microbiota in the environment of meat processing plants: the microbiota of three different meat plants was studied by both traditional and molecular methods (PCR-DGGE) in two different periods. Different levels of contamination emerged between the three plants as well as between the two sampling periods. Conventional methods of killing free-living bacteria through antimicrobial agents and disinfection are often ineffective against bacteria within a biofilm. The use of gas-discharge plasmas potentially can offer a good alternative to conventional sterilization methods. The purpose of this study was to measure the effectiveness of Atmospheric Pressure Plasma (APP) surface treatments against bacteria in biofilms. Biofilms produced by three different L. monocytogenes strains on stainless steel surface were subjected to three different conditions (power, exposure time) of APP. Our results showed how most of the culturable cells are inactivated after the Plasma exposure but the RNA analysis by qPCR highlighted the entrance of the cells in the viable-but non culturable (VBNC) state, confirming the hypothesis that cells are damaged after plasma treatment, but in a first step, still remain alive. The understanding of the effects of APP on the L. monocytogenes biofilm can improve the development of sanitation programs with the use of APP for effective pathogen removal.

  20. Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials

    NASA Technical Reports Server (NTRS)

    Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger

    2004-01-01

    A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.