Performance of conventionally powered vehicles tested to an electric vehicle test procedure
NASA Technical Reports Server (NTRS)
Slavik, R. J.; Dustin, M. O.; Lumannick, S.
1977-01-01
A conventional Volkswagen transporter, a Renault 5, a Pacer, and a U. S. Postal Service general DJ-5 delivery van were treated to an electric vehicle test procedure in order to allow direct comparison of conventional and electric vehicles. Performance test results for the four vehicles are presented.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-23
... Conservation Program: Test Procedures for Residential Dishwashers, Dehumidifiers, and Conventional Cooking... conventional cooking products under the Energy Policy and Conservation Act. DATES: The effective date of this...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-31
...The U.S. Department of Energy (DOE) establishes new test procedures for residential dishwashers and dehumidifiers, and amends the currently applicable test procedure for conventional cooking products under the Energy Policy and Conservation Act. The new test procedures include provisions for measuring standby mode and off mode energy consumption, and update the provisions for measuring active mode energy consumption and, for dishwashers, water consumption. This final rule also amends the certification, compliance, and enforcement requirements for dishwashers, dehumidifiers and conventional cooking products, amends certain provisions in the currently applicable dishwasher test procedure, and eliminates an obsolete energy efficiency metric in the dishwasher test procedure and provisions in the cooking products test procedure that have become obsolete due to the elimination of standing pilot lights.
NASA Astrophysics Data System (ADS)
1984-09-01
This Test Operations Procedure (TOP) provides conventional test methods employing conventional test instrumentation for testing conventional radars. Single tests and subtests designed to test radar components, transmitters, receivers, antennas, etc., and system performance are conducted with single item instruments such as meters, generators, attenuators, counters, oscillators, plotters, etc., and with adequate land areas for conducting field tests.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-10
... to amend the test procedures for residential dishwashers, dehumidifiers, and conventional cooking... procedures for residential dishwashers, dehumidifiers, and conventional cooking products, go to the Federal e..., dehumidifiers, and conventional cooking products (77 FR 65942, Oct. 31, 2012) and its direct final rule to amend...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harry, T; Yaddanapudi, S; Mutic, S
Purpose: New techniques and materials have recently been developed to expedite the conventional Linac Acceptance Testing Procedure (ATP). The new ATP method uses the Electronic Portal Imaging Device (EPID) for data collection and is presented separately. This new procedure is meant to be more efficient then conventional methods. While not clinically implemented yet, a prospective risk assessment is warranted for any new techniques. The purpose of this work is to investigate the risks and establish the pros and cons between the conventional approach and the new ATP method. Methods: ATP tests that were modified and performed with the EPID weremore » analyzed. Five domain experts (Medical Physicists) comprised the core analysis team. Ranking scales were adopted from previous publications related to TG 100. The number of failure pathways for each ATP test procedure were compared as well as the number of risk priority numbers (RPN’s) greater than 100 were compared. Results: There were fewer failure pathways with the new ATP compared to the conventional, 262 and 556, respectively. There were fewer RPN’s > 100 in the new ATP compared to the conventional, 41 and 115. Failure pathways and RPN’s > 100 for individual ATP tests on average were 2 and 3.5 times higher in the conventional ATP compared to the new, respectively. The pixel sensitivity map of the EPID was identified as a key hazard to the new ATP procedure with an RPN of 288 for verifying beam parameters. Conclusion: The significant decrease in failure pathways and RPN’s >100 for the new ATP mitigates the possibilities of a catastrophic error occurring. The Pixel Sensitivity Map determining the response and inherent characteristics of the EPID is crucial as all data and hence results are dependent on that process. Grant from Varian Medical Systems Inc.« less
Using Interactive Computing to Expand Intelligence Testing: A Critique and Prospectus.
ERIC Educational Resources Information Center
Hunt, Earl; Pellegrino, James
1985-01-01
There are economic advantages in using microcomputers as automated testing stations for measuring aptitude and intelligence. Microcomputers also make it possible to expand and modify testing procedures for psychological functions included in conventional tests and to test psychological functions not generally assessed by conventional tests, such…
Are minimally invasive procedures harder to acquire than conventional surgical procedures?
Hiemstra, Ellen; Kolkman, Wendela; le Cessie, Saskia; Jansen, Frank Willem
2011-01-01
It is frequently suggested that minimally invasive surgery (MIS) is harder to acquire than conventional surgery. To test this hypothesis, residents' learning curves of both surgical skills are compared. Residents had to be assessed using a general global rating scale of the OSATS (Objective Structured Assessment of Technical Skills) for every procedure they performed as primary surgeon during a 3-month clinical rotation in gynecological surgery. Nine postgraduate-year-4 residents collected a total of 319 OSATS during the 2 years and 3 months investigation period. These assessments concerned 129 MIS (laparoscopic and hysteroscopic) and 190 conventional (open abdominal and vaginal) procedures. Learning curves (in this study defined as OSATS score plotted against procedure-specific caseload) for MIS and conventional surgery were compared using a linear mixed model. The MIS curve revealed to be steeper than the conventional curve (1.77 vs. 0.75 OSATS points per assessed procedure; 95% CI 1.19-2.35 vs. 0.15-1.35, p < 0.01). Basic MIS procedures do not seem harder to acquire during residency than conventional surgical procedures. This may have resulted from the incorporation of structured MIS training programs in residency. Hopefully, this will lead to a more successful implementation of the advanced MIS procedures. Copyright © 2010 S. Karger AG, Basel.
Precision of guided scanning procedures for full-arch digital impressions in vivo.
Zimmermann, Moritz; Koller, Christina; Rumetsch, Moritz; Ender, Andreas; Mehl, Albert
2017-11-01
System-specific scanning strategies have been shown to influence the accuracy of full-arch digital impressions. Special guided scanning procedures have been implemented for specific intraoral scanning systems with special regard to the digital orthodontic workflow. The aim of this study was to evaluate the precision of guided scanning procedures compared to conventional impression techniques in vivo. Two intraoral scanning systems with implemented full-arch guided scanning procedures (Cerec Omnicam Ortho; Ormco Lythos) were included along with one conventional impression technique with irreversible hydrocolloid material (alginate). Full-arch impressions were taken three times each from 5 participants (n = 15). Impressions were then compared within the test groups using a point-to-surface distance method after best-fit model matching (OraCheck). Precision was calculated using the (90-10%)/2 quantile and statistical analysis with one-way repeated measures ANOVA and post hoc Bonferroni test was performed. The conventional impression technique with alginate showed the lowest precision for full-arch impressions with 162.2 ± 71.3 µm. Both guided scanning procedures performed statistically significantly better than the conventional impression technique (p < 0.05). Mean values for group Cerec Omnicam Ortho were 74.5 ± 39.2 µm and for group Ormco Lythos 91.4 ± 48.8 µm. The in vivo precision of guided scanning procedures exceeds conventional impression techniques with the irreversible hydrocolloid material alginate. Guided scanning procedures may be highly promising for clinical applications, especially for digital orthodontic workflows.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-15
...The U.S. Department of Energy (DOE) proposes to amend its test procedures for residential dishwashers to update certain obsolete dishware, flatware and food items, make minor amendments to the definition of the normal cycle, and update the ambient temperature and preconditioning requirements as well as the industry test method referenced in DOE's test procedure. DOE also proposes to add water pressure, drain height, rack position, loading, rinse aid container, and soil preparation specifications to the dishwasher test procedure. DOE additionally proposes to amend the test procedures for both dishwashers and conventional cooking products for the measurement of energy use in fan-only mode.
The Effects of Item by Item Feedback Given during an Ability Test.
ERIC Educational Resources Information Center
Whetton, C.; Childs, R.
1981-01-01
Answer-until-correct (AUC) is a procedure for providing feedback during a multiple-choice test, giving an increased range of scores. The performance of secondary students on a verbal ability test using AUC procedures was compared with a group using conventional instructions. AUC scores considerably enhanced reliability but not validity.…
Ronco, Guglielmo; Giorgi-Rossi, Paolo; Carozzi, Francesca; Dalla Palma, Paolo; Del Mistro, Annarosa; De Marco, Laura; De Lillo, Margherita; Naldoni, Carlo; Pierotti, Paola; Rizzolo, Raffaella; Segnan, Nereo; Schincaglia, Patrizia; Zorzi, Manuel; Confortini, Massimo; Cuzick, Jack
2006-07-01
Testing for human papillomavirus (HPV) DNA is more sensitive but less specific than cytological analysis. Loss in specificity is most relevant in women younger than 35 years because of increased HPV prevalence. We aimed to compare conventional screening with an experimental strategy in women aged 25-34 years, and investigate the effect of different criteria of referral to define the best methods of HPV screening. Women were randomly assigned to the conventional procedure (standard cytology, with referral to colposcopy if cytology showed atypical squamous cells of undetermined significance or more [ASCUS+]) or an experimental procedure (liquid-based cytology and testing for high-risk HPV types, with referral to colposcopy with ASCUS+ cytology). Women positive for HPV (cutoff > or = 1 pg/mL) but with normal cytology were retested after 1 year. The main endpoint was the presence of cervical intraepithelial neoplasia at grade 2 or more (CIN2+) in reviewed histology. The main analysis was by intention to screen. This trial is registered as an International Standard Randomised Controlled Trial, number ISRCTN81678807. We randomly assigned 5808 women aged 25-34 years to the conventional group and 6002 to the experimental group. The experimental procedure was significantly more sensitive than the conventional procedure (55 vs 33 CIN2+ lesions detected; relative sensitivity 1.61 [95% CI 1.05-2.48]), but had a lower positive predictive value (PPV; relative PPV 0.55 [0.37-0.82]). HPV testing (> or = 1 pg/mL) with cytology triage was also more sensitive than conventional cytology (relative sensitivity 1.58 [1.03-2.44], relative PPV 0.78 [0.52-1.16]). Relative PPV could be improved, with minimum loss in sensitivity, by use of a 2 pg/mL cutoff for HPV testing. Compared with conventional cytology, liquid-based cytology had a relative sensitivity of 1.32 (0.84-2.06), relative PPV 0.58 [0.38-0.89]). HPV testing alone with cytology triage could be a feasible alternative to conventional cytology for screening women younger than 35 years. Follow-up will provide data on possible overdiagnosis and on the feasibility of extended intervals.
Walpita, P; Darougar, S
1989-07-01
The development and application of a double-label immunofluorescence method which has the potential to screen for single or dual infections from any site, in single shell vial cultures, is described. In this study, a total of 1,141 ocular specimens were inoculated in shell vials, centrifuged at 15,000 X g for 1 h, incubated at 37 degrees C for 48 h, and fixed in methanol at room temperature for 15 min. The virus inclusions were detected by staining with a double-label indirect immunofluorescence procedure using mixtures of appropriate first antibodies, followed by fluorescein- and rhodamine-conjugated second antibodies. Each specimen was also inoculated in parallel by the conventional virus isolation method. The sensitivity and specificity of the double-label shell vial procedure were comparable to those with the conventional method, and the former test took only 48 h to complete. The test offers a rapid and simple single-vial procedure which allows for individual or simultaneous detection of multiple pathogens. It results in savings in time and cost over the conventional virus isolation method and other shell vial procedures.
Joda, Tim; Brägger, Urs
2016-12-01
The aim of this randomized controlled trial was to compare patient-centered outcomes during digital and conventional implant impressions. In a crossover study design, intraoral scanning (IOS) [test] as well as classical polyether impressions [control] were both performed on 20 patients for single-tooth replacement with implant-supported crowns. The sequential distribution of either starting with the test or the control procedure was randomly selected. Patients' perception and satisfaction on the level of convenience-related factors were assessed with visual analogue scale (VAS) questionnaires. In addition, clinical work time was separately recorded for test and control procedures. Statistical analyses were performed with Wilcoxon signed-rank tests and corrected for multiple testing by the method of Holm. On VAS ranging from 0 to 100, patients scored a mean convenience level of 78.6 (SD ± 14.0) in favor of IOS compared to conventional impressions with 53.6 (SD ± 15.4) [P = 0.0001]. All included patients would prefer the digital workflow if in the future they could choose between the two techniques. Secondary, IOS was significantly faster with 14.8 min (SD ± 2.2) compared to the conventional approach with 17.9 min (SD ± 1.1) [P = 0.0001]. Based on the findings of this investigation, both impression protocols worked successfully for all study participants capturing the 3D implant positions. However, the digital technique emerges as the most preferred one according to patient-centered outcomes and was more time-effective compared to conventional impressions. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Stargel, D; Thompson, F S; Phillips, S E; Lombard, G L; Dowell, V R
1976-01-01
The Minitek Miniaturized System (BBL) was modified for characterization of anaerobic bacteria. The modified system and the conventional Center for Disease Control method were used to test a variety of anaerobic bacteria, and results were compared. Tests performed by both techniques were indole and H2S production, esculin hydrolysis, nitrate reduction, and fermentation of glucose, mannitol, lactose, sucrose, maltose, salicin, glycerol, xylose, arabinose, mannose, rhamnose, and trehalose. The manufacturer's recommended procedure for the Minitek system was modified by using a new suspension medium (Lombard-Dowell broth) and an inoculum equivalent to the density of a McFarland no. 5 nephelometer standard. The Minitek results, recorded after 48 h, agreed satisfactorily with the conventional test results, usually recorded after 5 to 7 days of incubation. In the examination of 80 strains representing 22 different species or subspecies of anaerobic bacteria, with 16 biochemical tests performed in triplicate, 93.8% of the Minitek test results agreed with those of the corresponding conventional tests. Only tests for indole, H2S, and nitrate reduction gave less than 90% agreement. It was concluded that the modified Minitek system is a suitable substitute for the more expensive and time-consuming conventional procedure for determining carbohydrate fermentation and esculin hydrolysis by anaerobes. This system, when used in conjunction with other tests, can effectively aid in the definitive identification of commonly isolated anaerobes. Images PMID:773959
Shokry, Mohamed; Aboelsaad, Nayer
2016-01-01
The purpose of this study was to test the effect of the surgical removal of impacted mandibular third molars using piezosurgery versus the conventional surgical technique on postoperative sequelae and bone healing. Material and Methods. This study was carried out as a randomized controlled clinical trial: split mouth design. Twenty patients with bilateral mandibular third molar mesioangular impaction class II position B indicated for surgical extraction were treated randomly using either the piezosurgery or the conventional bur technique on each site. Duration of the procedure, postoperative edema, trismus, pain, healing, and bone density and quantity were evaluated up to 6 months postoperatively. Results. Test and control sites were compared using paired t-test. There was statistical significance in reduction of pain and swelling in test sites, where the time of the procedure was statistically increased in test site. For bone quantity and quality, statistical difference was found where test site showed better results. Conclusion. Piezosurgery technique improves quality of patient's life in form of decrease of postoperative pain, trismus, and swelling. Furthermore, it enhances bone quality within the extraction socket and bone quantity along the distal aspect of the mandibular second molar. PMID:27597866
Screening tests for pathogenic corynebacteria.
Colman, G; Weaver, E; Efstratiou, A
1992-01-01
AIM: To provide simple tests that would help in the identification of corynebacteria that produce diphtheria toxin. METHODS: A collection of 99 freshly isolated corynebacteria was assembled and the cultures identified by conventional tests confirmed by an identification kit. Modifications were made to procedures for preparation of the culture medium for the Elek test and to the test for detection of pyrazinamidase (pyrazine carboxylamidase) activity. These two together with an indicator medium for cystinase activity were applied to the collection of organisms. RESULTS: Cystinase was detected in all 61 members of the toxigenic species and none produced pyrazinamidase. In contrast, all but two of the 38 representatives of non-toxigenic species yielded pyrazinamidase and none formed cystinase. Of the 61 cystinase producing cultures (which were also pyrazinamidase negative), 21 gave a positive Elek test with the modified culture medium. A total of 30 of these 61 were tested for toxigenicity in guinea pigs and the results of the animal and plate tests concorded. At least seven cultures could have been reported as non-toxigenic if Elek tests based on media prepared in the conventional way had been the only test available. CONCLUSION: The three procedures described go some way towards meeting the needs of diagnostic laboratories for efficient procedures for distinguishing pathogenic corynebacteria. PMID:1740514
ERIC Educational Resources Information Center
Campos, Heloisa Cursi; Debert, Paula; Barros, Romariz da Silva; McIlvane, William J.
2011-01-01
A go/no-go procedure with compound stimuli typically establishes emergent behavior that parallels in structure and typical outcome that of conventional tests for symmetric, transitive, and equivalence relations in normally capable adults. The present study employed a go/no-go compound stimulus procedure with pigeons. During training, pecks to…
Polyzois, Ioannis; Claffey, Noel; McDonald, Albhe; Hussey, David; Quinn, Frank
2011-05-01
The purpose of this study was to examine the effectiveness of conventional pre-clinical training in dentistry and to determine if evaluation of a dental procedure at the beginning of dental training can be a predictor for future performance. A group of second year dental students with no previous experience in operative dentistry were asked to prepare a conventional class I cavity on a lower first molar typodont. Their first preparation was carried out after an introductory lecture and a demonstration and their second at the end of conventional training. The prepared typodonts were coded and blindly scored for the traditional assessment criteria of outline form, retention form, smoothness, cavity depth and cavity margin angulation. Once the codes were broken, a paired t-test was used to compare the difference between the means of before and after scores (P<0.0001) and a Pearson's linear correlation to test the association (r=0.4). From the results of this study, we could conclude that conventional preclinical training results in a significant improvement in the manual skills of the dental students and that the dental procedure used had only a limited predictive value for later performance at the preclinical level. © 2011 John Wiley & Sons A/S.
APEX/SPIN: a free test platform to measure speech intelligibility.
Francart, Tom; Hofmann, Michael; Vanthornhout, Jonas; Van Deun, Lieselot; van Wieringen, Astrid; Wouters, Jan
2017-02-01
Measuring speech intelligibility in quiet and noise is important in clinical practice and research. An easy-to-use free software platform for conducting speech tests is presented, called APEX/SPIN. The APEX/SPIN platform allows the use of any speech material in combination with any noise. A graphical user interface provides control over a large range of parameters, such as number of loudspeakers, signal-to-noise ratio and parameters of the procedure. An easy-to-use graphical interface is provided for calibration and storage of calibration values. To validate the platform, perception of words in quiet and sentences in noise were measured both with APEX/SPIN and with an audiometer and CD player, which is a conventional setup in current clinical practice. Five normal-hearing listeners participated in the experimental evaluation. Speech perception results were similar for the APEX/SPIN platform and conventional procedures. APEX/SPIN is a freely available and open source platform that allows the administration of all kinds of custom speech perception tests and procedures.
40 CFR 1066.415 - Vehicle operation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Vehicle operation. 1066.415 Section... VEHICLE-TESTING PROCEDURES Preparing Vehicles and Running an Exhaust Emission Test § 1066.415 Vehicle operation. This section describes how to test a conventionally configured vehicle (vehicles with...
Dynamic Testing and Test Anxiety amongst Gifted and Average-Ability Children
ERIC Educational Resources Information Center
Vogelaar, Bart; Bakker, Merel; Elliott, Julian G.; Resing, Wilma C. M.
2017-01-01
Background: Dynamic testing has been proposed as a testing approach that is less disadvantageous for children who may be potentially subject to bias when undertaking conventional assessments. For example, those who encounter high levels of test anxiety, or who are unfamiliar with standardized test procedures, may fail to demonstrate their true…
Ganier, Franck; Hoareau, Charlotte; Tisseau, Jacques
2014-01-01
Virtual reality opens new opportunities for operator training in complex tasks. It lowers costs and has fewer constraints than traditional training. The ultimate goal of virtual training is to transfer knowledge gained in a virtual environment to an actual real-world setting. This study tested whether a maintenance procedure could be learnt equally well by virtual-environment and conventional training. Forty-two adults were divided into three equally sized groups: virtual training (GVT® [generic virtual training]), conventional training (using a real tank suspension and preparation station) and control (no training). Participants then performed the procedure individually in the real environment. Both training types (conventional and virtual) produced similar levels of performance when the procedure was carried out in real conditions. Performance level for the two trained groups was better in terms of success and time taken to complete the task, time spent consulting job instructions and number of times the instructor provided guidance.
Validation of a New Procedure for Impedance Eduction in Flow
NASA Technical Reports Server (NTRS)
Watson, W. R.; Jones, M. G.
2010-01-01
A new impedance eduction procedure is validated by comparing the educed impedance spectrum to that of an older but well-tested eduction procedure. The older procedure requires the installation of a microphone array in the liner test section but the new procedure removes this requirement. A 12.7-mm stainless steel plate and a conventional liner consisting of a perforated plate bonded to a honeycomb core are tested. Test data is acquired from a grazing flow, impedance tube facility for a range of source frequencies and mean flow Mach numbers for which only plane waves are cut on. For the stainless steel plate, the educed admittance spectrum using the new procedure shows an improvement over that of the old procedure. This improvement shows up primarily in the educed conductance spectrum. Both eduction procedures show discrepancies in educed admittance in the mid-frequency range. Indications are that this discrepancy is triggered by an inconsistency between the measured eduction data (that contains boundary layer effects) and the two eduction models (for which the boundary layer is neglected). For the conventional liner, both eduction procedures are in very good agreement with each other. Small discrepancies occur for one or two frequencies in the mid-frequency range and for frequencies beyond the cut on frequency of higher-order duct modes. This discrepancy in the midfrequency range occurs because an automated optimizer is used to educe the impedance and the objective function used by the optimizer is extremely flat and therefore sensitive to initial starting values. The discrepancies at frequencies beyond the cut on frequency of higher order duct modes are due to the assumption of only plane waves in the impedance eduction model, although higher order modes are propagating in the impedance tube facility.
A New Comparison Between Conventional Indexing (MEDLARS) and Automatic Text Processing (SMART)
ERIC Educational Resources Information Center
Salton, G.
1972-01-01
A new testing process is described. The design of the test procedure is covered in detail, and the several language processing features incorporated into the SMART system are individually evaluated. (20 references) (Author)
Pre-Then-Post Testing: A Tool To Improve the Accuracy of Management Training Program Evaluation.
ERIC Educational Resources Information Center
Mezoff, Bob
1981-01-01
Explains a procedure to avoid the detrimental biases of conventional self-reports of training outcomes. The evaluation format provided is a method for using statistical procedures to increase the accuracy of self-reports by overcoming response-shift-bias. (Author/MER)
Crew Procedures for Continuous Descent Arrivals Using Conventional Guidance
NASA Technical Reports Server (NTRS)
Oseguera-Lohr, Rosa M.; Williams, David H.; Lewis, Elliot T,
2007-01-01
This paper presents results from a simulation study which investigated the use of Continuous Descent Arrival (CDA) procedures for conducting a descent through a busy terminal area, using conventional transport-category automation. This research was part of the Low Noise Flight Procedures (LNFP) element within the Quiet Aircraft Technology (QAT) Project, that addressed development of flight guidance, and supporting pilot and Air Traffic Control (ATC) procedures for low noise operations. The procedures and chart were designed to be easy to understand, and to make it easy for the crew to make changes via the Flight Management Computer Control-Display Unit (FMC-CDU) to accommodate changes from ATC. The test runs were intended to represent situations typical of what exists in many of today's terminal areas, including interruptions to the descent in the form of clearances issued by ATC.
Comparing the 810nm diode laser with conventional surgery in orthodontic soft tissue procedures.
Ize-Iyamu, I N; Saheeb, B D; Edetanlen, B E
2013-09-01
To compare the use of the 810nm diode laser with conventional surgery in the management of soft tissue mucogingival problems associated with orthodontic treatment. Orthodontic patients requiring different soft tissue surgical procedures were randomly assigned to receive conventional surgery or soft tissue diode laser, (wavelength 810 nm). Parameters documented include the type of anaesthesia used, intra and post operative pain, bleeding, the use of scalpel and sutures. The chi-squared test was used to test for significance at 95% confidence level. Probability values (p-values) less than 0.05 were regarded as significant. Only 2(16.7%) of the procedures carried out with the soft tissue laser required infiltration anaesthesia compared to 10 (90.9%) with conventional surgery and this was significant (P<0.001). Post operative pain was significantly reduced in all cases treated with the diode laser (P<0.001). There was also a significant difference (P<0.05) in post operative bleeding in all cases treated with the diode laser. No sutures were used in all soft tissue cases managed with the diode laser and this was significant (P<0.001). There was no statistically significant difference in treatment time in the use of the laser compared with conventional surgery. Orthodontic patients treated with the diode laser required less infiltration anaesthesia, had reduced bleeding during and after surgery, rapid postoperative haemostasis, elimination of the need for sutures and an improved postoperative comfort and healing.
19 CFR 115.31 - Examination, inspection, and testing.
Code of Federal Regulations, 2010 CFR
2010-04-01
...; DEPARTMENT OF THE TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS Procedures for Approval of Containers by Design Type § 115.31 Examination, inspection, and testing... Authority shall conduct such examinations, inspections, and tests of the production run containers as it...
19 CFR 115.31 - Examination, inspection, and testing.
Code of Federal Regulations, 2012 CFR
2012-04-01
...; DEPARTMENT OF THE TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS Procedures for Approval of Containers by Design Type § 115.31 Examination, inspection, and testing... Authority shall conduct such examinations, inspections, and tests of the production run containers as it...
19 CFR 115.31 - Examination, inspection, and testing.
Code of Federal Regulations, 2011 CFR
2011-04-01
...; DEPARTMENT OF THE TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS Procedures for Approval of Containers by Design Type § 115.31 Examination, inspection, and testing... Authority shall conduct such examinations, inspections, and tests of the production run containers as it...
19 CFR 115.31 - Examination, inspection, and testing.
Code of Federal Regulations, 2014 CFR
2014-04-01
...; DEPARTMENT OF THE TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS Procedures for Approval of Containers by Design Type § 115.31 Examination, inspection, and testing... Authority shall conduct such examinations, inspections, and tests of the production run containers as it...
19 CFR 115.31 - Examination, inspection, and testing.
Code of Federal Regulations, 2013 CFR
2013-04-01
...; DEPARTMENT OF THE TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS Procedures for Approval of Containers by Design Type § 115.31 Examination, inspection, and testing... Authority shall conduct such examinations, inspections, and tests of the production run containers as it...
40 CFR 53.21 - Test conditions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Test conditions. 53.21 Section 53.21... Methods for SO2, CO, O3, and NO2 § 53.21 Test conditions. (a) Set-up and start-up of the test analyzer... before beginning the tests. The test procedures assume that the test analyzer has a conventional analog...
Soluble Antigen Fluorescent-Antibody Technique
Toussaint, Andre J.; Anderson, Robert I.
1965-01-01
An indirect fluorescent-antibody (FA) procedure employing soluble antigen fixed onto an artificial matrix was developed, and a mechanical means for reading of test results was devised. The method employs two small cellulose acetate paper discs for each test. One disc contains soluble antigen diluted in 1% bovine serum albumin (BSA); the other contains only 1% BSA and serves as a control. After testing by the indirect FA procedure, the results of the tests are read on a fluorometer fitted with a paper chromatogram door. The instrument is set at zero with the control disc as a blank, and the specific fluorescence of the antigen disc is determined. Findings obtained with homologous and heterologous antisera indicated that the method yields excellent results. The soluble antigen fluorescent-antibody technique has definite advantages over the conventional indirect FA procedures. (i) The investigator may objectively select the antigen to be employed. (ii) It is possible to obtain objective mechanical reading of test results rather than the highly subjective readings required by conventional methods. (iii) The system compensates for any nonspecific fluorescence contributed either by the serum (e.g., drugs) or by free fluorescein in the conjugated antiserum. Images Fig. 1 PMID:14339261
Analysis of fracture in sheet bending and roll forming
NASA Astrophysics Data System (ADS)
Deole, Aditya D.; Barnett, Matthew; Weiss, Matthias
2018-05-01
The bending limit or minimum bending radius of sheet metal is conventionally measured in a wiping (swing arm) or in a vee bend test and reported as the minimum radius of the tool over which the sheet can be bent without fracture. Frequently the material kinks while bending so that the actual inner bend radius of the sheet metal is smaller than the tool radius giving rise to inaccuracy in these methods. It has been shown in the previous studies that conventional bend test methods may under-estimate formability in bending dominated processes such as roll forming. A new test procedure is proposed here to improve understanding and measurement of fracture in bending and roll forming. In this study, conventional wiping test and vee bend test have been performed on martensitic steel to determine the minimum bend radius. In addition, the vee bend test is performed in an Erichsen sheet metal tester equipped with the GOM Aramis system to enable strain measurement on the outer surface during bending. The strain measurement before the onset of fracture is then used to determine the minimum bend radius. To compare this result with a technological process, a vee channel is roll formed and in-situ strain measurement carried out with the Vialux Autogrid system. The strain distribution at fracture in the roll forming process is compared with that predicted by the conventional bending tests and by the improved process. It is shown that for this forming operation and material, the improved procedure gives a more accurate prediction of fracture.
Improved Tensile Test for Ceramics
NASA Technical Reports Server (NTRS)
Osiecki, R. A.
1982-01-01
For almost-nondestructive tensile testing of ceramics, steel rod is bonded to sample of ceramic. Assembly is then pulled apart in conventional tensile-test machine. Test destroys only shallow surface layer which can be machined away making specimen ready for other uses. Method should be useful as manufacturing inspection procedure for low-strength brittle materials.
What Happened to the Streptococci: Overview of Taxonomic and Nomenclature Changes
Facklam, Richard
2002-01-01
Since the division of the Streptococcus genus into enterococci, lactococci, and streptococci in 1984, many changes in the nomenclature and taxonomy of the Streptococcus genus have taken place. The application of genetic comparisons has improved the proper classification of the different species. The Lancefield system of serogrouping the streptococci by the expression of beta-hemolysis on blood agar plates is still very useful for the identification of streptococci for patient management. The Lancefield grouping system cannot be used in itself for accurate identification of specific beta-hemolytic species, but it can be a useful part of the identification procedure. Except for identification of the “Streptococcus bovis group” of species and Streptococcus suis, Lancefield grouping is of little value in identification of the non-beta-hemolytic streptococci and related genera. In fact, identification of the non-beta-hemolytic species is problematic for conventional as well as commercially available identification procedures. A combination of conventional tests and specific chromogenic tests suggested by several investigators is presented and discussed. Tables are included that suggest tests and procedures to guide investigators attempting to identify all the species. PMID:12364372
Gaensslen, R E; Lee, H C; Carroll, J E
1984-01-01
Two different monoclonal anti-A and anti-B and several different affinity purified Ulex europaeus lectin I reagents were evaluated and compared with conventional anti-A and anti-B sera and Ulex anti-H for serologic properties, in inhibition tests with secretor salivas, and in elution tests with bloodstains. The monoclonal and purified reagents were found to be comparable to conventional ones, and accordingly suitable for forensic inhibition and elution procedures.
Jung, Gyu-Un; Kim, Jun Hwan; Lim, Nam Hun; Yoon, Gil Ho; Han, Ji-Young
2017-06-01
Ridge splitting techniques are used for horizontal ridge augmentation in implant dentistry. Recently, a novel engine-driven ridge splitting technique was introduced. This study compared the mechanical forces produced by conventional and engine-driven ridge splitting techniques in porcine mandibles. In 33 pigs, mandibular premolar areas were selected for the ridge splitting procedures, designed as a randomized split-mouth study. The conventional group underwent a chisel-and-mallet procedure (control group, n = 20), and percussive impulse (Newton second, Ns) was measured using a sensor attached to the mallet. In the engine-driven ridge spreader group (test group, n = 23), a load cell was used to measure torque values (Newton centimeter, Ncm). Horizontal acceleration generated during procedures (control group, n = 10 and test group, n = 10) was compared between the groups. After ridge splitting, the alveolar crest width was significantly increased both in the control (1.23 ± 0.45 mm) and test (0.98 ± 0.41 mm) groups with no significant differences between the groups. The average impulse of the control group was 4.74 ± 1.05 Ns. Torque generated by rotation in the test group was 9.07 ± 2.15 Ncm. Horizontal acceleration was significantly less in the test group (0.82 ± 1.05 g) than the control group (64.07 ± 42.62 g) (P < 0.001). Narrow edentulous ridges can be expanded by novel engine-driven ridge spreaders. Within the limits of this study, the results suggested that an engine-driven ridge splitting technique may be less traumatic and less invasive than a conventional ridge splitting technique. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Sibbitt, Wilmer; Sibbitt, Randy R; Michael, Adrian A; Fu, Druce I; Draeger, Hilda T; Twining, Jon M; Bankhurst, Arthur D
2006-04-01
To evaluate physician control of needle and syringe during aspiration-injection syringe procedures by comparing the new reciprocating procedure syringe to a traditional conventional syringe. Twenty-six physicians were tested for their individual ability to control the reciprocating and conventional syringes in typical aspiration-injection procedures using a novel quantitative needle-based displacement procedure model. Subsequently, the physicians performed 48 clinical aspiration-injection (arthrocentesis) procedures on 32 subjects randomized to the reciprocating or conventional syringes. Clinical outcomes included procedure time, patient pain, and operator satisfaction. Multivariate modeling methods were used to determine the experimental variables in the syringe control model most predictive of clinical outcome measures. In the model system, the reciprocating syringe significantly improved physician control of the syringe and needle, with a 66% reduction in unintended forward penetration (p < 0.001) and a 68% reduction in unintended retraction (p < 0.001). In clinical arthrocentesis, improvements were also noted: 30% reduction in procedure time (p < 0.03), 57% reduction in patient pain (p < 0.001), and a 79% increase in physician satisfaction (p < 0.001). The variables in the experimental system--unintended forward penetration, unintended retraction, and operator satisfaction--independently predicted the outcomes of procedure time, patient pain, and physician satisfaction in the clinical study (p < or = 0.001). The reciprocating syringe reduces procedure time and patient pain and improves operator satisfaction with the procedure syringe. The reciprocating syringe improves physician performance in both the validated quantitative needle-based displacement model and in real aspiration-injection syringe procedures, including arthrocentesis.
Some ideas and opportunities concerning three-dimensional wind-tunnel wall corrections
NASA Technical Reports Server (NTRS)
Rubbert, P. E.
1982-01-01
Opportunities for improving the accuracy and reliability of wall corrections in conventional ventilated test sections are presented. The approach encompasses state-of-the-art technology in transonic computational methods combined with the measurement of tunnel-wall pressures. The objective is to arrive at correction procedures of known, verifiable accuracy that are practical within a production testing environment. It is concluded that: accurate and reliable correction procedures can be developed for cruise-type aerodynamic testing for any wall configuration; passive walls can be optimized for minimal interference for cruise-type aerodynamic testing (tailored slots, variable open area ratio, etc.); monitoring and assessment of noncorrectable interference (buoyancy and curvature in a transonic stream) can be an integral part of a correction procedure; and reasonably good correction procedures can probably be developd for complex flows involving extensive separation and other unpredictable phenomena.
UV disinfection in drinking water supplies.
Hoyer, O
2000-01-01
UV disinfection has become a practical and safely validatable disinfection procedure by specifying the requirements for testing and monitoring in DVGW standard W 294. A standardized biodosimetric testing procedure and monitoring with standardized UV sensors is introduced and successfully applied. On-line monitoring of irradiance can be counterchecked with handheld reference sensors and makes it possible that UV systems can be used for drinking water disinfection with the same level of confidence and safety as is conventional chemical disinfection.
NASA Astrophysics Data System (ADS)
Kramer, Hendrik; Klein, Marcus; Eifler, Dietmar
Conventional methods to characterize the fatigue behavior of metallic materials are very time and cost consuming. That is why the new short-time procedure PHYBALCHT was developed at the Institute of Materials Science and Engineering at the University of Kaiserslautern. This innovative method requires only a planar material surface to perform cyclic force-controlled hardness indentation tests. To characterize the cyclic elastic-plastic behavior of the test material the change of the force-indentation-depth-hysteresis is plotted versus the number of indentation cycles. In accordance to the plastic strain amplitude the indentation-depth width of the hysteresis loop is measured at half minimum force and is called plastic indentation-depth amplitude. Its change as a function of the number of cycles of indentation can be described by power-laws. One of these power-laws contains the hardening-exponentCHT e II , which correlates very well with the amount of cyclic hardening in conventional constant amplitude fatigue tests.
Evaluation of the pathotec Rapid I-D system for identification of Enterobacteriaceae.
Smith, P B; Rhoden, D L; Tomfohrde, K M
1975-01-01
The PathoTec Rapid I-D System for identifying Enterobacteriaceae was evaluated with 471 cultures. In 4,910 individual test comparisons, 95.5% of the results agreed, with results of only two test strips, those for esculin hydrolysis and urease production, agreeing with conventional tests in less than 94% of the trials. The PathoTec system exhibited 94.3% accuracy in identifying these cultures in a double-blind study with conventional media and procedures as the alternate system. Two newly developed test strips, for 0-nitrophenyl-beta-D-galactopyranoside and ornithine decarboxylase, were found to be highly reliable. PMID:1041590
False Discovery Control in Large-Scale Spatial Multiple Testing
Sun, Wenguang; Reich, Brian J.; Cai, T. Tony; Guindani, Michele; Schwartzman, Armin
2014-01-01
Summary This article develops a unified theoretical and computational framework for false discovery control in multiple testing of spatial signals. We consider both point-wise and cluster-wise spatial analyses, and derive oracle procedures which optimally control the false discovery rate, false discovery exceedance and false cluster rate, respectively. A data-driven finite approximation strategy is developed to mimic the oracle procedures on a continuous spatial domain. Our multiple testing procedures are asymptotically valid and can be effectively implemented using Bayesian computational algorithms for analysis of large spatial data sets. Numerical results show that the proposed procedures lead to more accurate error control and better power performance than conventional methods. We demonstrate our methods for analyzing the time trends in tropospheric ozone in eastern US. PMID:25642138
Correcting for Indirect Range Restriction in Meta-Analysis: Testing a New Meta-Analytic Procedure
ERIC Educational Resources Information Center
Le, Huy; Schmidt, Frank L.
2006-01-01
Using computer simulation, the authors assessed the accuracy of J. E. Hunter, F. L. Schmidt, and H. Le's (2006) procedure for correcting for indirect range restriction, the most common type of range restriction, in comparison with the conventional practice of applying the Thorndike Case II correction for direct range restriction. Hunter et…
19 CFR 115.66 - Examination, inspection, and testing.
Code of Federal Regulations, 2010 CFR
2010-04-01
...; DEPARTMENT OF THE TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS Procedures for Approval of Road Vehicles by Design Type § 115.66 Examination, inspection, and... 19 Customs Duties 1 2010-04-01 2010-04-01 false Examination, inspection, and testing. 115.66...
19 CFR 115.66 - Examination, inspection, and testing.
Code of Federal Regulations, 2012 CFR
2012-04-01
...; DEPARTMENT OF THE TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS Procedures for Approval of Road Vehicles by Design Type § 115.66 Examination, inspection, and... 19 Customs Duties 1 2012-04-01 2012-04-01 false Examination, inspection, and testing. 115.66...
19 CFR 115.66 - Examination, inspection, and testing.
Code of Federal Regulations, 2014 CFR
2014-04-01
...; DEPARTMENT OF THE TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS Procedures for Approval of Road Vehicles by Design Type § 115.66 Examination, inspection, and... 19 Customs Duties 1 2014-04-01 2014-04-01 false Examination, inspection, and testing. 115.66...
19 CFR 115.66 - Examination, inspection, and testing.
Code of Federal Regulations, 2013 CFR
2013-04-01
...; DEPARTMENT OF THE TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS Procedures for Approval of Road Vehicles by Design Type § 115.66 Examination, inspection, and... 19 Customs Duties 1 2013-04-01 2013-04-01 false Examination, inspection, and testing. 115.66...
19 CFR 115.66 - Examination, inspection, and testing.
Code of Federal Regulations, 2011 CFR
2011-04-01
...; DEPARTMENT OF THE TREASURY CARGO CONTAINER AND ROAD VEHICLE CERTIFICATION PURSUANT TO INTERNATIONAL CUSTOMS CONVENTIONS Procedures for Approval of Road Vehicles by Design Type § 115.66 Examination, inspection, and... 19 Customs Duties 1 2011-04-01 2011-04-01 false Examination, inspection, and testing. 115.66...
Cost effectiveness of conventional versus LANDSAT use data for hydrologic modeling
NASA Technical Reports Server (NTRS)
George, T. S.; Taylor, R. S.
1982-01-01
Six case studies were analyzed to investigate the cost effectiveness of using land use data obtained from LANDSAT as opposed to conventionally obtained data. A procedure was developed to determine the relative effectiveness of the two alternative means of acquiring data for hydrological modelling. The cost of conventionally acquired data ranged between $3,000 and $16,000 for the six test basins. Information based on LANDSAT imagery cost between $2,000 and $5,000. Results of the effectiveness analysis shows the differences between the two methods are insignificant. From the cost comparison and the act that each method, conventional and LANDSAT, is shown to be equally effective in developing land use data for hydrologic studies, the cost effectiveness of the conventional or LANDSAT method is found to be a function of basin size for the six test watersheds analyzed. The LANDSAT approach is cost effective for areas containing more than 10 square miles.
New heterogeneous test statistics for the unbalanced fixed-effect nested design.
Guo, Jiin-Huarng; Billard, L; Luh, Wei-Ming
2011-05-01
When the underlying variances are unknown or/and unequal, using the conventional F test is problematic in the two-factor hierarchical data structure. Prompted by the approximate test statistics (Welch and Alexander-Govern methods), the authors develop four new heterogeneous test statistics to test factor A and factor B nested within A for the unbalanced fixed-effect two-stage nested design under variance heterogeneity. The actual significance levels and statistical power of the test statistics were compared in a simulation study. The results show that the proposed procedures maintain better Type I error rate control and have greater statistical power than those obtained by the conventional F test in various conditions. Therefore, the proposed test statistics are recommended in terms of robustness and easy implementation. ©2010 The British Psychological Society.
Revised Robertson's test theory of special relativity
NASA Astrophysics Data System (ADS)
Vargas, José G.
1984-07-01
The only test theory used by workers in the field of testing special relativity to analyze the significance of their experiments is the proof by H. P. Robertson [ Rev. Mod. Phys. 21, 378 (1949)] of the Lorentz transformations from the results of the experimental evidence. Some researchers would argue that the proof contains an unwarranted assumption disguised as a convention about synchronization procedures. Others would say that alternative conventions are possible. In the present paper, no convention is used, but the Lorentz transformations are still obtained using only the results of the experiments in Robertson's proof, namely the Michelson-Morley, Kennedy-Thorndike, and Ives-Stilwell experiments. Thus the revised proof is a valid test theory which is independent of any conventions, since one appeals only to the experimental evidence. The analysis of that evidence shows the directions in which efforts to test special relativity should go. Finally it is shown how the resulting test theory still has to be improved for consistency in the analysis of experiments with complicated experimental setups, how it can be simplified for expediency as to what should be tested, and how it should be completed for a missing step not considered by Robertson.
Relative toxicity of pyrolysis products of some foams and fabrics
NASA Technical Reports Server (NTRS)
Hilado, C. J.
1976-01-01
A limited number of foams and fabrics was evaluated in the course of developing test procedures for determining the relative toxicity of materials. The principal variable studied, heating rate, did not affect the relative ranking of the materials tested. Two pyrolysis test procedures using the same basic approach but employing different sample weights, chamber volumes, laboratory animals, heating rates, and upper temperature limits, resulted in identical rankings of relative toxicity. The data obtained show that modification of conventional flexible polyurethane foams with flame retardants to comply with California upholstered furniture flammability regulations seems to consistently reduce toxicity under pyrolysis conditions.
NASA Technical Reports Server (NTRS)
Horvath, R. (Principal Investigator); Cicone, R.; Crist, E.; Kauth, R. J.; Lambeck, P.; Malila, W. A.; Richardson, W.
1979-01-01
The author has identified the following significant results. An outgrowth of research and development activities in support of LACIE was a multicrop area estimation procedure, Procedure M. This procedure was a flexible, modular system that could be operated within the LACIE framework. Its distinctive features were refined preprocessing (including spatially varying correction for atmospheric haze), definition of field like spatial features for labeling, spectral stratification, and unbiased selection of samples to label and crop area estimation without conventional maximum likelihood classification.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-20
...Where appropriate, the U.S. Department of Energy (DOE) has proposed to amend its test procedures for residential dishwashers, dehumidifiers, and conventional cooking products (which includes cooktops, ovens, and ranges) to include provisions for measuring standby mode and off mode energy consumption, as required by the Energy Independence and Security Act of 2007 (EISA 2007). These test procedure amendments would incorporate by reference certain provisions of the International Electrotechnical Commission (IEC) Standard 62301, ``Household electrical appliances--Measurement of standby power.'' Since publication of DOE's initial proposal in December 2010, the IEC has replaced the First Edition of this standard with the current Second Edition. This supplemental notice of proposed rulemaking proposes to incorporate the latest edition of IEC Standard 62301.
NASA Technical Reports Server (NTRS)
Parrish, R. V.; Mckissick, B. T.; Steinmetz, G. G.
1979-01-01
A recent modification of the methodology of profile analysis, which allows the testing for differences between two functions as a whole with a single test, rather than point by point with multiple tests is discussed. The modification is applied to the examination of the issue of motion/no motion conditions as shown by the lateral deviation curve as a function of engine cut speed of a piloted 737-100 simulator. The results of this application are presented along with those of more conventional statistical test procedures on the same simulator data.
El-Kholey, Khalid E; Ramasamy, Saravanan; Kumar R, Sheetal; Elkomy, Aamna
2017-12-01
To test the hypothesis that there would be no difference in heat production by reducing the number of drills during the implant site preparation relative to conventional drilling sequence. A total of 120 implant site preparations with 3 different diameters (3.6, 4.3, and 4.6 mm) were performed on bovine ribs. Within the same diameter group, half of the preparations were performed by a simplified drilling procedure (pilot drill + final diameter drill) and other half using the conventional drilling protocol (pilot drill followed by graduated series of drills to widen the site). Heat production by different drilling techniques was evaluated by measuring the bone temperature using k-type thermocouple and a sensitive thermometer before and after each drill. Mean for maximum temperature increase during site preparation of the 3.6, 4.3, and 4.6-mm implants was 2.45, 2.60, and 2.95° when the site was prepared by the simplified procedure, whereas it was 2.85, 3.10, and 3.60° for the sites prepared by the conventional technique, respectively. No significant difference in temperature increase was found when implants of the 3 different diameters were prepared either by the conventional or simplified drilling procedure. The simplified drilling technique produced similar amount of heat comparable to the conventional technique that proved the initial hypothesis.
El-Kholey, Khalid E; Elkomy, Aamna
2016-12-01
To test the hypothesis that there would be no difference in heat generation by reducing the number of drills during the implant site preparation relative to conventional drilling sequence. A total of 80 implant site preparations with 2 different diameters (5.6 and 6.2 mm) were performed on bovine ribs. Within the same diameter group, half of the preparations were performed by a simplified drilling procedure (pilot drill + final diameter drill) and the other half using the conventional drilling protocol, where multiple drills of increasing diameter were utilized. Heat production by different drilling techniques was evaluated by measuring the bone temperature using K-type thermocouple and a sensitive thermometer before and after each drill. Mean for maximum temperature increase during site preparation of the 5.6- and 6.2-mm implants was 2.20°C, and it was 2.55°C when the site was prepared by the simplified procedure, whereas it was 2.80°C and 2.95°C for the sites prepared by the conventional technique, respectively. No significant difference in temperature increase was found when implants of the 2 chosen diameters were prepared either by the conventional or simplified drilling procedure. The simplified drilling protocol produces similar amount of heat comparable to the conventional technique, which proved the initial hypothesis.
NASA Astrophysics Data System (ADS)
Kusumo, B. H.; Sukartono, S.; Bustan, B.
2018-02-01
Measuring soil organic carbon (C) using conventional analysis is tedious procedure, time consuming and expensive. It is needed simple procedure which is cheap and saves time. Near infrared technology offers rapid procedure as it works based on the soil spectral reflectance and without any chemicals. The aim of this research is to test whether this technology able to rapidly measure soil organic C in rice paddy field. Soil samples were collected from rice paddy field of Lombok Island Indonesia, and the coordinates of the samples were recorded. Parts of the samples were analysed using conventional analysis (Walkley and Black) and some other parts were scanned using near infrared spectroscopy (NIRS) for soil spectral collection. Partial Least Square Regression (PLSR) Models were developed using data of soil C analysed using conventional analysis and data from soil spectral reflectance. The models were moderately successful to measure soil C in rice paddy field of Lombok Island. This shows that the NIR technology can be further used to monitor the C change in rice paddy soil.
Nojavan, Saeed; Sirani, Mahsa; Asadi, Sakine
2017-10-01
In this study, electromembrane extraction from a flowing sample solution, termed as continuous-flow electromembrane extraction, was developed and compared with conventional procedures for the determination of four basic drugs in real samples. Experimental parameters affecting the extraction efficiency were further studied and optimized. Under optimum conditions, linearity of continuous-flow procedure was within 8.0-500 ng/mL, while it was wider for conventional procedures (2.0-500 ng/mL). Moreover, repeatability (percentage relative standard deviation) was found to range between 5.6 and 10.4% (n = 3) for the continuous-flow procedure, with a better repeatability than that of conventional procedures (2.3-5.5% (n = 3)). Also, for the continuous-flow procedure, the estimated detection limit (signal-to-noise ratio = 3) was less than 2.4 ng/mL and extraction recoveries were within 8-10%, while the corresponding figures for conventional procedures were less than 0.6 ng/mL and 42-60%, respectively. Thus, the results showed that both continuous flow and conventional procedures were applicable for the extraction of model compounds. However, the conventional procedure was more convenient to use, and thus it was applied to determine sample drugs in real urine and wastewater samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A new tensile impact test for the toughness characterization of sheet material
NASA Astrophysics Data System (ADS)
Könemann, Markus; Lenz, David; Brinnel, Victoria; Münstermann, Sebastian
2018-05-01
In the past, the selection of suitable steels has been carried out primarily based on the mechanical properties of different steels. One of these properties is the resistance against crack propagation. For many constructions, this value plays an important role, because it can compare the impact toughness of different steel grades easily and gives information about the loading capacity of the specific materials. For thin sheets, impact toughness properties were usually not considered. One of the reasons for this is that the Charpy-impact test is not applicable for sheets with thicknesses below 2 mm. For a long time, this was not relevant because conventional steels had a sufficient impact toughness in a wide temperature range. However, since new multiphase steel grades with improved mechanical property exploitations are available, it turned out that impact toughness properties need to be considered during the component design phase, as the activation of the cleavage fracture mechanism is observed under challenging loading conditions. Therefore, this work aims to provide a new and practical testing procedure for sheet material or thin walled structures. The new testing procedure is based on tensile tests conducted in an impact pendulum similar to the Charpy impact hammer. A new standard geometry is provided, which enables a comparison between different steels or steel grades. A connection to the conventional Charpy test is presented using a damage mechanics model, which predicts material failure with consideration of to the stress state at various temperatures. Different specimen geometries are analysed to cover manifold stress states. A special advantage of the damage mechanics model is also the possibility to predict the materials behaviour in the transition area. To verify the method a conventional steel was tested in Charpy tests as well as in the new tensile impact test.
Development and evaluation of the impulse transfer function technique
NASA Technical Reports Server (NTRS)
Mantus, M.
1972-01-01
The development of the test/analysis technique known as the impulse transfer function (ITF) method is discussed. This technique, when implemented with proper data processing systems, should become a valuable supplement to conventional dynamic testing and analysis procedures that will be used in the space shuttle development program. The method can relieve many of the problems associated with extensive and costly testing of the shuttle for transient loading conditions. In addition, the time history information derived from impulse testing has the potential for being used to determine modal data for the structure under investigation. The technique could be very useful in determining the time-varying modal characteristics of structures subjected to thermal transients, where conventional mode surveys are difficult to perform.
Holzhütter, H G; Genschow, E; Diener, W; Schlede, E
2003-05-01
The acute toxic class (ATC) methods were developed for determining LD(50)/LC(50) estimates of chemical substances with significantly fewer animals than needed when applying conventional LD(50)/LC(50) tests. The ATC methods are sequential stepwise procedures with fixed starting doses/concentrations and a maximum of six animals used per dose/concentration. The numbers of dead/moribund animals determine whether further testing is necessary or whether the test is terminated. In recent years we have developed classification procedures for the oral, dermal and inhalation routes of administration by using biometric methods. The biometric approach assumes a probit model for the mortality probability of a single animal and assigns the chemical to that toxicity class for which the best concordance is achieved between the statistically expected and the observed numbers of dead/moribund animals at the various steps of the test procedure. In previous publications we have demonstrated the validity of the biometric ATC methods on the basis of data obtained for the oral ATC method in two-animal ring studies with 15 participants from six countries. Although the test procedures and biometric evaluations for the dermal and inhalation ATC methods have already been published, there was a need for an adaptation of the classification schemes to the starting doses/concentrations of the Globally Harmonized Classification System (GHS) recently adopted by the Organization for Economic Co-operation and Development (OECD). Here we present the biometric evaluation of the dermal and inhalation ATC methods for the starting doses/concentrations of the GHS and of some other international classification systems still in use. We have developed new test procedures and decision rules for the dermal and inhalation ATC methods, which require significantly fewer animals to provide predictions of toxicity classes, that are equally good or even better than those achieved by using the conventional LD(50)/LC(50) methods. In order to cope with rather narrow dose/concentration classes of the GHS we have, as in our previous publications, combined the outcome of all results that can be obtained during testing for the allocation to one of the defined toxicity classes of the GHS. Our results strongly recommend the deletion of the dermal LD(50) and the inhalation LC(50) test as regulatory tests and the adoption of the dermal and inhalation ATC methods as internationally accepted alternatives.
Two diesel trucks equipped with a particulate filter (DPF) were tested at two ambient temperatures (70oF and 20oF), fuels (ultra low sulfur diesel (ULSD) and biodiesel (B20)) and operating loads (a heavy and light weight). The test procedure included three driving cycles, a cold ...
Sikiric, P; Separovic, J; Buljat, G; Anic, T; Stancic-Rokotov, D; Mikus, D; Marovic, A; Prkacin, I; Duplancic, B; Zoricic, I; Aralica, G; Lovric-Bencic, M; Ziger, T; Perovic, D; Rotkvic, I; Mise, S; Hanzevacki, M; Hahn, V; Seiwerth, S; Turkovic, B; Grabarevic, Z; Petek, M; Rucman, R
2000-01-01
Various antidepressants have antiulcer activity. Likewise, the models currently used in ulcers and depression disorders research have a considerable degree of similarity. Therefore, the possibility that depression disorders could be effectively influenced by a primary antiulcer agent with a cyto/organoprotective activity, such as the novel stomach pentadecapeptide BPC 157, was investigated in two rat depression assays. First, a forced swimming test (a Porsolt's procedure) was used. As a more severe procedure, chronic unpredictable stress (after 5 d of unpredictable stress protocol, once daily drug application during stress procedure, open field-immobility test assessment at fourth or sixth day of medication) was used. In a forced swimming test, a reduction of the immobility time in BPC 157 (10 microg, 10 ng x kg(-1) i.p.) treated rats corresponds to the activity of the 15 mg or 40 mg (i.p.) of conventional antidepressants, imipramine or nialamide, respectively, given according to the original Porsolt's protocol. In chronic unpredictable stress procedure, particular aggravation of experimental conditions markedly affected the conventional antidepressant activity, whereas BPC 157 effectiveness was continuously present. The effect of daily imipramine (30 mg) medication could be seen only after a more prolonged period, but not after a shorter period (i.e., 4-d protocol). In these conditions, no delay in the effectiveness was noted in BPC 157 medication and a reduction of the immobility of chronically stressed rats was noted after both 4 and 6 d of BPC 157 (10 microg, 10 ng) medication.
Laparoendoscopic single-site Heller myotomy with anterior fundoplication for achalasia.
Barry, Linda; Ross, Sharona; Dahal, Sujat; Morton, Connor; Okpaleke, Chinyere; Rosas, Melissa; Rosemurgy, Alexander S
2011-06-01
Laparoendoscopic single-site (LESS) surgery is beginning to include advanced laparoscopic operations such as Heller myotomy with anterior fundoplication. However, the efficacy of LESS Heller myotomy has not been established. This study aimed to evaluate the authors' initial experience with LESS Heller myotomy for achalasia. Transumbilical LESS Heller myotomy with concomitant anterior fundoplication for achalasia was undertaken for 66 patients after October 2007. Outcomes including operative time, complications, and length of hospital stay were recorded and compared with those for an earlier contiguous group of 66 consecutive patients undergoing conventional multi-incision laparoscopic Heller myotomy with anterior fundoplication. Symptoms before and after myotomy were scored by the patients using a Likert scale ranging from 0 (never/not severe) to 10 (always/very severe). Data were analyzed using the Mann-Whitney U test, the Wilcoxon matched-pairs test, and Fisher's exact test where appropriate. Patients undergoing LESS Heller myotomy were similar to those undergoing conventional laparoscopic Heller myotomy in gender, age, body mass index (BMI), blood loss, and length of hospital stay. However, the patients undergoing LESS Heller myotomies had operations of significantly longer duration (median, 117 vs. 93 min with the conventional laparoscopic approach) (p<0.003). For 11 patients (16%) undergoing LESS Heller myotomy, additional ports/incisions were required. No patients were converted to "open" operations, and no patients had procedure-specific complications. Symptom reduction was dramatic and satisfying after both LESS and conventional laparoscopic myotomy with fundoplication. The symptom reduction was similar with the two procedures. The LESS approach left no apparent umbilical scar. Heller myotomy with anterior fundoplication effectively treats achalasia. The findings showed LESS Heller myotomy with anterior fundoplication to be feasible, safe, and efficacious. Although the LESS approach increases operative time, it does not increase procedure-related morbidity or hospital length of stay and avoids apparent umbilical scarring. Laparoendoscopic single-site surgery represents a paradigm shift to more minimally invasive surgery and is applicable to advanced laparoscopic operations such as Heller myotomy and anterior fundoplication.
In situ impulse test: an experimental and analytical evaluation of data interpretation procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1975-08-01
Special experimental field testing and analytical studies were undertaken at Fort Lawton in Seattle, Washington, to study ''close-in'' wave propagation and evaluate data interpretation procedures for a new in situ impulse test. This test was developed to determine the shear wave velocity and dynamic modulus of soils underlying potential nuclear power plant sites. The test is different from conventional geophysical testing in that the velocity variation with strain is determined for each test. In general, strains between 10/sup -1/ and 10/sup -3/ percent are achieved. The experimental field work consisted of performing special tests in a large test sand fillmore » to obtain detailed ''close-in'' data. Six recording transducers were placed at various points on the energy source, while approximately 37 different transducers were installed within the soil fill, all within 7 feet of the energy source. Velocity measurements were then taken simultaneously under controlled test conditions to study shear wave propagation phenomenology and help evaluate data interpretation procedures. Typical test data are presented along with detailed descriptions of the results.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
..., certain conventional gasoline imported by truck, previously certified gasoline used to produce gasoline... Agreed upon procedures for GTAB, certain conventional gasoline imported by truck, previously certified gasoline used to produce gasoline, and butane blenders. (a) Attest procedures for GTAB. The following are...
Code of Federal Regulations, 2011 CFR
2011-07-01
..., certain conventional gasoline imported by truck, previously certified gasoline used to produce gasoline... Agreed upon procedures for GTAB, certain conventional gasoline imported by truck, previously certified gasoline used to produce gasoline, and butane blenders. (a) Attest procedures for GTAB. The following are...
Code of Federal Regulations, 2013 CFR
2013-07-01
..., certain conventional gasoline imported by truck, previously certified gasoline used to produce gasoline... Agreed upon procedures for GTAB, certain conventional gasoline imported by truck, previously certified gasoline used to produce gasoline, and butane blenders. (a) Attest procedures for GTAB. The following are...
Code of Federal Regulations, 2012 CFR
2012-07-01
..., certain conventional gasoline imported by truck, previously certified gasoline used to produce gasoline... Agreed upon procedures for GTAB, certain conventional gasoline imported by truck, previously certified gasoline used to produce gasoline, and butane blenders. (a) Attest procedures for GTAB. The following are...
Code of Federal Regulations, 2014 CFR
2014-07-01
..., certain conventional gasoline imported by truck, previously certified gasoline used to produce gasoline... Agreed upon procedures for GTAB, certain conventional gasoline imported by truck, previously certified gasoline used to produce gasoline, and butane blenders. (a) Attest procedures for GTAB. The following are...
Evaluation of mix designs and test procedures for pervious concrete.
DOT National Transportation Integrated Search
2014-10-01
Pervious concrete is mixture of cement, aggregate, and water that provide a level of porosity which allows : water to percolate into the sub-grade. It differs from the conventional concrete since it usually contains a : smaller amount of fine aggrega...
A simple, less invasive stripper micropipetter-based technique for day 3 embryo biopsy.
Cedillo, Luciano; Ocampo-Bárcenas, Azucena; Maldonado, Israel; Valdez-Morales, Francisco J; Camargo, Felipe; López-Bayghen, Esther
2016-01-01
Preimplantation genetic screening (PGS) is an important procedure for in vitro fertilization (IVF). A key step of PGS, blastomere removal, is abundant with many technical issues. The aim of this study was to compare a more simple procedure based on the Stipper Micropipetter, named S-biopsy, to the conventional aspiration method. On Day 3, 368 high-quality embryos (>7 cells on Day3 with <10% fragmentation) were collected from 38 women. For each patient, their embryos were equally separated between the conventional method ( n = 188) and S-biopsy method ( n = 180). The conventional method was performed using a standardized protocol. For the S-biopsy method, a laser was used to remove a significantly smaller portion of the zona pellucida. Afterwards, the complete embryo was aspirated with a Stripper Micropipetter, forcing the removal of the blastomere. Selected blastomeres went to PGS using CGH microarrays. Embryo integrity and blastocyst formation were assessed on Day 5. Differences between groups were assessed by either the Mann-Whitney test or Fisher Exact test. Both methods resulted in the removal of only one blastomere. The S-biopsy and the conventional method did not differ in terms of affecting embryo integrity (95.0% vs. 95.7%) or blastocyst formation (72.7% vs. 70.7%). PGS analysis indicated that aneuploidy rate were similar between the two methods (63.1% vs. 65.2%). However, the time required to perform the S-biopsy method (179.2 ± 17.5 s) was significantly shorter (5-fold) than the conventional method. The S-biopsy method is comparable to the conventional method that is used to remove a blastomere for PGS, but requires less time. Furthermore, due to the simplicity of the S-biopsy technique, this method is more ideal for IVF laboratories.
1992-10-01
intelligence developed an authentic European conflict scenario based on WINTEX- CIMEX , a detailed European command post exercise. One of the primary...them. The only exercises in which we effectively train from start to finish are the large CPXs like WINTEX/ CIMEX . This exercise is a procedural...general war CPX, sponsored by the Joint Chiefs of Staff. WINTEX/ CIMEX exercises. tests, and evaluates command and control procedures. planning. and
An elutriation apparatus for assessing settleability of combined sewer overflows (CSOs).
Marsalek, J; Krishnappan, B G; Exall, K; Rochfort, Q; Stephens, R P
2006-01-01
An elutriation apparatus was proposed for testing the settleability of combined sewer outflows (CSOs) and applied to 12 CSO samples. In this apparatus, solids settling is measured under dynamic conditions created by flow through a series of settling chambers of varying diameters and upward flow velocities. Such a procedure reproduces better turbulent settling in CSO tanks than the conventional settling columns, and facilitates testing coagulant additions under dynamic conditions. Among the limitations, one could name the relatively large size of the apparatus and samples (60 L), and inadequate handling of floatables. Settleability results obtained for the elutriation apparatus and a conventional settling column indicate large inter-event variation in CSO settleability. Under such circumstances, settling tanks need to be designed for "average" conditions and, within some limits, the differences in test results produced by various settleability testing apparatuses and procedures may be acceptable. Further development of the elutriation apparatus is under way, focusing on reducing flow velocities in the tubing connecting settling chambers and reducing the number of settling chambers employed. The first measure would reduce the risk of floc breakage in the connecting tubing and the second one would reduce the required sample size.
Stübig, Timo; Petri, Maximilian; Zeckey, Christian; Hawi, Nael; Krettek, Christian; Citak, Musa; Meller, Rupert
2013-12-01
Reversed shoulder arthroplasty is an alternative to total shoulder arthroplasty for various indications. The long-term results depend on stable bone fixation, and correct positioning of the glenoid component. The potential contribution of image guidance for reversed shoulder arthroplasty procedures was tested in vitro. 27 positioning procedures (15 navigated, 12 non-navigated) of the glenoid baseplate in reverse shoulder arthroplasty were performed by a single experienced orthopaedic surgeon. A Kirschner wire was placed freehand or with the use of a navigated drill guide. For the navigated procedures, a flat detector 3D C-arm with navigation system was used. The Kirschner wire was to be inserted 12 mm from the inferior glenoid, with an inferior tilt of 10° and centrally in the axial scapular axis. The insertion point in the glenoid as well as the position of the K-wire in the axial and sagittal planes were measured. For statistical analysis, t-tests were performed with a significance level of 0.05. The inferior glenoid drilling distance was 14.1 ± 3.4 mm for conventional placement and 15.1 ± 3.4 mm for the navigated procedure (P = 0.19). The inferior tilt showed no significant difference between the two methods (conventional 7.4 ± 5.2°, navigated 7.7 ± 4.9°, P = 0.63). The glenoid version in the axial plane showed significantly higher accuracy for the navigated procedure, with a mean deviation of 1.6 ±4.5° for the navigated procedure compared with 11.5 ± 6.5° for the conventional procedure(P = 0.004). Accurate positioning of the glenoidal baseplate in the axial scapular plane can be improved using 3D C-arm navigation for reversed shoulder arthroplasty. However, computer navigation may not improve the inferior tilt of the component or the position in the inferior glenoid to avoid scapular notching. Nevertheless, further studies are required to confirm these findings in the clinical setup. Copyright © 2013 John Wiley & Sons, Ltd.
Accelerated Testing of Polymeric Composites Using the Dynamic Mechanical Analyzer
NASA Technical Reports Server (NTRS)
Abdel-Magid, Becky M.; Gates, Thomas S.
2000-01-01
Creep properties of IM7/K3B composite material were obtained using three accelerated test methods at elevated temperatures. Results of flexural creep tests using the dynamic mechanical analyzer (DMA) were compared with results of conventional tensile and compression creep tests. The procedures of the three test methods are described and the results are presented. Despite minor differences in the time shift factor of the creep compliance curves, the DMA results compared favorably with the results from the tensile and compressive creep tests. Some insight is given into establishing correlations between creep compliance in flexure and creep compliance in tension and compression. It is shown that with careful consideration of the limitations of flexure creep, a viable and reliable accelerated test procedure can be developed using the DMA to obtain the viscoelastic properties of composites in extreme environments.
Rose, A; Suttor, S; Goebell, P J; Rossi, R; Rübben, H
2007-09-01
Transurethral resection in a conductive irrigant medium is a new procedure in the surgical therapy of bladder tumors and prostate enlargement. In this prospective randomized trial we compared conventional TUR with TUR in saline regarding safety and efficiency. Between November 2004 and February 2005 a total number of 128 patients were included in this study. After randomization 58 patients were treated by conventional TUR and 70 patients by TURIS (Olympus, SurgMasterSystem). We evaluated resection time, weight of resected tissue, complications, blood loss, changes in serum sodium, and duration of catheterization. Among the tested procedures no statistically significant difference could be observed concerning blood loss, change of serum sodium, and complications. The mean weight of resected tissue of the prostate per time was 0.9 g/min with the TUR procedure and 0.8 g/min with the TURIS procedure. Severe complications like TUR syndrome or perforation of the bladder were not observed at all. In the TURIS group time until catheter removal was longer but also the mean weight of resected tissue of the prostate was higher in the TURIS group (42 g) than in the conventional TUR group (31 g). Transurethral resection in a conductive irrigant medium (TURIS) can be considered as a safe and effective surgical procedure in the treatment of BPH and superficial urothelial carcinoma. Moreover the risk of TUR syndrome and perforation of the bladder due to nerve stimulation is reduced.
National Centers for Environmental Prediction
different sites - Examples of the testing on different sites - Computing Environment NCEPLIBS Documentation - Procedures and conventions for NCEPLIBS use - Tutorials of NCEPLIBS use. Examples - Applications and ) 5830 University Research Court College Park, MD 20740 Page Author: EMC Webmaster Page generated:Sunday
Alternative Strategies in Assessing Special Education Needs
ERIC Educational Resources Information Center
Dykeman, Bruce F.
2006-01-01
The conventional use of standardized testing within a discrepancy analysis model is reviewed. The Response-to-Intervention (RTI) process is explained, along with descriptions of assessment procedures within RTI: functional assessment, authentic assessment, curriculum-based measurement, and play-based assessment. Psychometric issues relevant to RTI…
Flow Cytometry Data Preparation Guidelines for Improved Automated Phenotypic Analysis.
Jimenez-Carretero, Daniel; Ligos, José M; Martínez-López, María; Sancho, David; Montoya, María C
2018-05-15
Advances in flow cytometry (FCM) increasingly demand adoption of computational analysis tools to tackle the ever-growing data dimensionality. In this study, we tested different data input modes to evaluate how cytometry acquisition configuration and data compensation procedures affect the performance of unsupervised phenotyping tools. An analysis workflow was set up and tested for the detection of changes in reference bead subsets and in a rare subpopulation of murine lymph node CD103 + dendritic cells acquired by conventional or spectral cytometry. Raw spectral data or pseudospectral data acquired with the full set of available detectors by conventional cytometry consistently outperformed datasets acquired and compensated according to FCM standards. Our results thus challenge the paradigm of one-fluorochrome/one-parameter acquisition in FCM for unsupervised cluster-based analysis. Instead, we propose to configure instrument acquisition to use all available fluorescence detectors and to avoid integration and compensation procedures, thereby using raw spectral or pseudospectral data for improved automated phenotypic analysis. Copyright © 2018 by The American Association of Immunologists, Inc.
SSME environment database development
NASA Technical Reports Server (NTRS)
Reardon, John
1987-01-01
The internal environment of the Space Shuttle Main Engine (SSME) is being determined from hot firings of the prototype engines and from model tests using either air or water as the test fluid. The objectives are to develop a database system to facilitate management and analysis of test measurements and results, to enter available data into the the database, and to analyze available data to establish conventions and procedures to provide consistency in data normalization and configuration geometry references.
Vexler, Albert; Yu, Jihnhee
2018-04-13
A common statistical doctrine supported by many introductory courses and textbooks is that t-test type procedures based on normally distributed data points are anticipated to provide a standard in decision-making. In order to motivate scholars to examine this convention, we introduce a simple approach based on graphical tools of receiver operating characteristic (ROC) curve analysis, a well-established biostatistical methodology. In this context, we propose employing a p-values-based method, taking into account the stochastic nature of p-values. We focus on the modern statistical literature to address the expected p-value (EPV) as a measure of the performance of decision-making rules. During the course of our study, we extend the EPV concept to be considered in terms of the ROC curve technique. This provides expressive evaluations and visualizations of a wide spectrum of testing mechanisms' properties. We show that the conventional power characterization of tests is a partial aspect of the presented EPV/ROC technique. We desire that this explanation of the EPV/ROC approach convinces researchers of the usefulness of the EPV/ROC approach for depicting different characteristics of decision-making procedures, in light of the growing interest regarding correct p-values-based applications.
Ramilo, Andrea; Navas, J Ignacio; Villalba, Antonio; Abollo, Elvira
2013-05-27
Bonamia ostreae and B. exitiosa have caused mass mortalities of various oyster species around the world and co-occur in some European areas. The World Organisation for Animal Health (OIE) has included infections with both species in the list of notifiable diseases. However, official methods for species-specific diagnosis of either parasite have certain limitations. In this study, new species-specific conventional PCR (cPCR) and real-time PCR techniques were developed to diagnose each parasite species. Moreover, a multiplex PCR method was designed to detect both parasites in a single assay. The analytical sensitivity and specificity of each new method were evaluated. These new procedures were compared with 2 OIE-recommended methods, viz. standard histology and PCR-RFLP. The new procedures showed higher sensitivity than the OIE recommended ones for the diagnosis of both species. The sensitivity of tests with the new primers was higher using oyster gills and gonad tissue, rather than gills alone. The lack of a 'gold standard' prevented accurate estimation of sensitivity and specificity of the new methods. The implementation of statistical tools (maximum likelihood method) for the comparison of the diagnostic tests showed the possibility of false positives with the new procedures, although the absence of a gold standard precluded certainty. Nevertheless, all procedures showed negative results when used for the analysis of oysters from a Bonamia-free area.
Sahm, Maik; Otto, Ronny; Pross, Matthias; Mantke, Rene
2018-06-25
Approximately 90,000 thyroid operations are performed in Germany each year. Minimally invasive video-assisted thyroidectomy (MIVAT) accounts for 5 - 10% of these operations. There are few data that compare long-term cosmetic results after MIVAT to those after conventional surgery. Current systematic reviews show no advantage for MIVAT. The goal of this study was to analyse the long-term postoperative results in both procedures and the evaluation of relevant factors. The analysis of the long-term results is based on follow-up examinations using a validated method for scar appraisal (POSAS). Cohort analysis was performed on MIVAT operations in our hospital between 2004 and 2011 and conventional thyroid operations in 2011. Follow-up examination data were analysed from 117 patients from the MIVAT group and 102 patients from the conventional group. The follow-up examination was performed with a mean of 23.1 vs. 23.6 months postoperatively (MIVAT vs. conventional). The Friedman Test showed that scar pigmentation (mean rank 4.79) and scar surface structure (mean rank 3.62) were the deciding factors influencing the long-term cosmetic results. Both MIVAT and conventional surgery gave very good long-term cosmetic results. From the patient's perspective, there is no significant advantage with conventional surgery. The evaluation of the long-term results largely depends on factors such as scar pigmentation and surface structure that can only be influenced to a limited extent by the surgical procedure. Georg Thieme Verlag KG Stuttgart · New York.
Vaidya, Sharad; Parkash, Hari; Bhargava, Akshay; Gupta, Sharad
2014-01-01
Abundant resources and techniques have been used for complete coverage crown fabrication. Conventional investing and casting procedures for phosphate-bonded investments require a 2- to 4-h procedure before completion. Accelerated casting techniques have been used, but may not result in castings with matching marginal accuracy. The study measured the marginal gap and determined the clinical acceptability of single cast copings invested in a phosphate-bonded investment with the use of conventional and accelerated methods. One hundred and twenty cast coping samples were fabricated using conventional and accelerated methods, with three finish lines: Chamfer, shoulder and shoulder with bevel. Sixty copings were prepared with each technique. Each coping was examined with a stereomicroscope at four predetermined sites and measurements of marginal gaps were documented for each. A master chart was prepared for all the data and was analyzed using Statistical Package for the Social Sciences version. Evidence of marginal gap was then evaluated by t-test. Analysis of variance and Post-hoc analysis were used to compare two groups as well as to make comparisons between three subgroups . Measurements recorded showed no statistically significant difference between conventional and accelerated groups. Among the three marginal designs studied, shoulder with bevel showed the best marginal fit with conventional as well as accelerated casting techniques. Accelerated casting technique could be a vital alternative to the time-consuming conventional casting technique. The marginal fit between the two casting techniques showed no statistical difference.
Dog EEG for wake-promotion studies.
Parmentier, Régis; Bricout, Denis; Brousseau, Emmanuel; Giboulot, Thierry
2006-10-01
Described in this unit is a protocol for investigating the wake-promoting activity of new chemical entities (NCEs) in dog. The experimental approach is based on scoring of sleep/wake stages in animals implanted with a telemetry device for recording EMG and cortical EEG signals. A major advantage of this procedure is that it is conducted in nontethered animals, limiting possible bias and complications encountered with conventional recording systems. In this procedure, polygraphic recording is conducted using four implanted beagles. Results of studies with modafinil, a wake-promoting agent, are described to demonstrate the utility of this test procedure.
Recommended procedures for measuring aircraft noise and associated parameters
NASA Technical Reports Server (NTRS)
Marsh, A. H.
1977-01-01
Procedures are recommended for obtaining experimental values of aircraft flyover noise levels (and associated parameters). Specific recommendations are made for test criteria, instrumentation performance requirements, data-acquisition procedures, and test operations. The recommendations are based on state-of-the-art measurement capabilities available in 1976 and are consistent with the measurement objectives of the NASA Aircraft Noise Prediction Program. The recommendations are applicable to measurements of the noise produced by an airplane flying subsonically over (or past) microphones located near the surface of the ground. Aircraft types covered by the recommendations are fixed-wing airplanes powered by turbojet or turbofan engines and using conventional aerodynamic means for takeoff and landing. Various assumptions with respect to subsequent data processing and analysis were made (and are described) and the recommended measurement procedures are compatible with the assumptions. Some areas where additional research is needed relative to aircraft flyover noise measurement techniques are also discussed.
Tsang, C.F.; Doughty, C.A.
1984-02-24
A well-test method involving injection of hot (or cold) water into a groundwater aquifer, or injecting cold water into a geothermal reservoir is disclosed. By making temperature measurements at various depths in one or more observation wells, certain properties of the aquifer are determined. These properties, not obtainable from conventional well test procedures, include the permeability anisotropy, and layering in the aquifer, and in-situ thermal properties. The temperature measurements at various depths are obtained from thermistors mounted in the observation wells.
Tsang, Chin-Fu; Doughty, Christine A.
1985-01-01
A well-test method involving injection of hot (or cold) water into a groundwater aquifer, or injecting cold water into a geothermal reservoir. By making temperature measurements at various depths in one or more observation wells, certain properties of the aquifer are determined. These properties, not obtainable from conventional well test procedures, include the permeability anisotropy, and layering in the aquifer, and in-situ thermal properties. The temperature measurements at various depths are obtained from thermistors mounted in the observation wells.
The Biological and Clinical Significance of Androgen Receptor Variants
2014-04-01
immunohistochemistry. We tested two antibodies purportedly specific for AR-V7: 1) a mouse monoclonal antibody available from A&G Precision Antibody...a gift from Dr. Luo and tested on AR-V7- high and -low cases from the mixed-grade cohort in our lab. We used a monoclonal antibody against AR as a...fold, as compared with conventional avidin- biotinylated enzyme complex (ABC) procedures. We tested this protocol on four cases of the mixed-grade
Degenerative lumbosacral stenosis in working dogs: current concepts and review.
Worth, A J; Thompson, D J; Hartman, A C
2009-12-01
Degenerative lumbosacral stenosis (DLSS) is characterised by intervertebral disc degeneration, with secondary bony and soft-tissue changes leading to compression of the cauda equina. Large-breed, active and working dogs are the most commonly affected by DLSS. Specific manipulative tests allow the clinician to form a high suspicion of DLSS, and initiate investigation. Changes seen using conventional radiography are unreliable, and although contrast radiography represents an improvement, advanced imaging is accepted as the diagnostic method of choice. Treatment involves decompression and/or stabilisation procedures in working dogs, although conservative management may be acceptable in pet dogs with mild signs. Prognosis for return to work is only fair, and there is a high rate of recurrence following conventional surgery. Stabilisation procedures are associated with the potential for failure of the implant, and their use has not gained universal acceptance. A new surgical procedure, dorsolateral foramenotomy, offers a potential advance in the management of DLSS. everal aspects of the pathogenesis, heritability and optimal treatment approach remain uncertain.
Environmental and toxicological planning in polymer production and disposal.
Levinskas, G J
1975-01-01
There is neither a prescribed format nor a rigid sequence of testing to follow for the assessment of health and environmental effects of chemicals. Conventional animal toxicity tests plus medical surveillance and monitoring of exposed human populations will provide knowledge of the biological effects of chemicals and assurance that they can be handled safely. Useful information also can be derived from other test procedures. These include extraction studies to measure the amounts of additives which can leach from polymers, toxicity tests using aquatic organisms and birds, and determination of the biodegradability of materials and their potential for accumulation and magnification in biological systems. Current concern over pyrolysis products of polymers points up the need for defining the variables involved and development of test procedures by which meaningful evaluations of potential health hazards can be made. PMID:1175554
Alejo, L; Corredoira, E; Sánchez-Muñoz, F; Huerga, C; Aza, Z; Plaza-Núñez, R; Serrada, A; Bret-Zurita, M; Parrón, M; Prieto-Areyano, C; Garzón-Moll, G; Madero, R; Guibelalde, E
2018-04-09
Objective: The new 2013/59 EURATOM Directive (ED) demands dosimetric optimisation procedures without undue delay. The aim of this study was to optimise paediatric conventional radiology examinations applying the ED without compromising the clinical diagnosis. Automatic dose management software (ADMS) was used to analyse 2678 studies of children from birth to 5 years of age, obtaining local diagnostic reference levels (DRLs) in terms of entrance surface air kerma. Given local DRL for infants and chest examinations exceeded the European Commission (EC) DRL, an optimisation was performed decreasing the kVp and applying the automatic control exposure. To assess the image quality, an analysis of high-contrast resolution (HCSR), signal-to-noise ratio (SNR) and figure of merit (FOM) was performed, as well as a blind test based on the generalised estimating equations method. For newborns and chest examinations, the local DRL exceeded the EC DRL by 113%. After the optimisation, a reduction of 54% was obtained. No significant differences were found in the image quality blind test. A decrease in SNR (-37%) and HCSR (-68%), and an increase in FOM (42%), was observed. ADMS allows the fast calculation of local DRLs and the performance of optimisation procedures in babies without delay. However, physical and clinical analyses of image quality remain to be needed to ensure the diagnostic integrity after the optimisation process. Advances in knowledge: ADMS are useful to detect radiation protection problems and to perform optimisation procedures in paediatric conventional imaging without undue delay, as ED requires.
78 FR 7939 - Energy Conservation Program: Test Procedures for Microwave Ovens (Active Mode)
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-04
...The U.S. Department of Energy (DOE) proposes to revise its test procedures for microwave ovens established under the Energy Policy and Conservation Act. The proposed amendments would add provisions for measuring the active mode energy use for microwave ovens, including both microwave-only ovens and convection microwave ovens. Specifically, DOE is proposing provisions for measuring the energy use of the microwave-only cooking mode for both microwave-only ovens and convection microwave ovens based on the testing methods in the latest draft version of the International Electrotechnical Commission Standard 60705, ``Household microwave ovens--Methods for measuring performance.'' DOE is proposing provisions for measuring the energy use of the convection-only cooking mode for convection microwave ovens based on the DOE test procedure for conventional ovens in our regulations. DOE is also proposing to calculate the energy use of the convection-microwave cooking mode for convection microwave ovens by apportioning the microwave-only mode and convection-only mode energy consumption measurements based on typical consumer use.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Clarification procedures; challenge... COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS CWC CLARIFICATION PROCEDURES (CONSULTATIONS AND CHALLENGE INSPECTIONS) § 717.1 Clarification procedures; challenge inspection requests pursuant to Article IX of the...
Al-mejrad, Lamya A.; Albarrag, Ahmed M.
2017-01-01
PURPOSE The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. MATERIALS AND METHODS Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. RESULTS There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure (P<.05). CONCLUSION The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures. PMID:29142649
Al-Fouzan, Afnan F; Al-Mejrad, Lamya A; Albarrag, Ahmed M
2017-10-01
The goal of this study was to compare the adhesion of Candida albicans to the surfaces of CAD/CAM and conventionally fabricated complete denture bases. Twenty discs of acrylic resin poly (methyl methacrylate) were fabricated with CAD/CAM and conventional procedures (heat-polymerized acrylic resin). The specimens were divided into two groups: 10 discs were fabricated using the CAD/CAM procedure (Wieland Digital Denture Ivoclar Vivadent), and 10 discs were fabricated using a conventional flasking and pressure-pack technique. Candida colonization was performed on all the specimens using four Candida albicans isolates. The difference in Candida albicans adhesion on the discs was evaluated. The number of adherent yeast cells was calculated by the colony-forming units (CFU) and by Fluorescence microscopy. There was a significant difference in the adhesion of Candida albicans to the complete denture bases created with CAD/CAM and the adhesion to those created with the conventional procedure. The CAD/CAM denture bases exhibited less adhesion of Candida albicans than did the denture bases created with the conventional procedure ( P <.05). The CAD/CAM procedure for fabricating complete dentures showed promising potential for reducing the adherence of Candida to the denture base surface. Clinical Implications. Complete dentures made with the CAD/CAM procedure might decrease the incidence of denture stomatitis compared with conventional dentures.
Ozawa, Daisuke; Suzuki, Yasunori; Kawamura, Noboru; Ohkubo, Chikahiro
2015-04-01
A crown restoration engaged by a clasp as an abutment tooth for a removable partial denture (RPD) occasionally might be removed and eliminated due to secondary caries or apical lesions. However, if the RPD is clinically acceptable without any problems and refabricating the RPD is not recommended, the new crown must be made to retrofit to the existing clasp of the RPD. This in vitro study evaluated the conventional and CAD/CAM procedures for retrofitting crown restorations to the existing clasps by measuring the fitness accuracy and the retentive forces. The crown restoration on #44 was fabricated with CP titanium and zirconium on the plaster model with #45 and #46 teeth missing to retrofit to the existing clasp using conventional thin coping and CAD/CAM procedures. The gap distance between the clasp (tip, shoulder, and rest regions) and the fabricated crown was measured using silicone impression material. The retentive force of the clasp was also measured, using an autograph at a crosshead speed of 50mm/min. The obtained data were analyzed by one-way ANOVA/Tukey's multiple comparison test (α=0.05). The CAD/CAM procedure caused significantly smaller gap distances in all of the clasp regions, as compared to the conventional procedure (p<0.05). The retentive force of the CAD/CAM crown was significantly higher than for the conventional one (p<0.05). When a crown restoration must be remade to retrofit an existing clasp, CAD/CAM fabrication can be recommended so that both appropriate fitness and retentive force are obtained. Copyright © 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Advantages and challenges in automated apatite fission track counting
NASA Astrophysics Data System (ADS)
Enkelmann, E.; Ehlers, T. A.
2012-04-01
Fission track thermochronometer data are often a core element of modern tectonic and denudation studies. Soon after the development of the fission track methods interest emerged for the developed an automated counting procedure to replace the time consuming labor of counting fission tracks under the microscope. Automated track counting became feasible in recent years with increasing improvements in computer software and hardware. One such example used in this study is the commercial automated fission track counting procedure from Autoscan Systems Pty that has been highlighted through several venues. We conducted experiments that are designed to reliably and consistently test the ability of this fully automated counting system to recognize fission tracks in apatite and a muscovite external detector. Fission tracks were analyzed in samples with a step-wise increase in sample complexity. The first set of experiments used a large (mm-size) slice of Durango apatite cut parallel to the prism plane. Second, samples with 80-200 μm large apatite grains of Fish Canyon Tuff were analyzed. This second sample set is characterized by complexities often found in apatites in different rock types. In addition to the automated counting procedure, the same samples were also analyzed using conventional counting procedures. We found for all samples that the fully automated fission track counting procedure using the Autoscan System yields a larger scatter in the fission track densities measured compared to conventional (manual) track counting. This scatter typically resulted from the false identification of tracks due surface and mineralogical defects, regardless of the image filtering procedure used. Large differences between track densities analyzed with the automated counting persisted between different grains analyzed in one sample as well as between different samples. As a result of these differences a manual correction of the fully automated fission track counts is necessary for each individual surface area and grain counted. This manual correction procedure significantly increases (up to four times) the time required to analyze a sample with the automated counting procedure compared to the conventional approach.
NASA Technical Reports Server (NTRS)
Sprowls, D. O.; Bucci, R. J.; Ponchel, B. M.; Brazill, R. L.; Bretz, P. E.
1984-01-01
A technique is demonstrated for accelerated stress corrosion testing of high strength aluminum alloys. The method offers better precision and shorter exposure times than traditional pass fail procedures. The approach uses data from tension tests performed on replicate groups of smooth specimens after various lengths of exposure to static stress. The breaking strength measures degradation in the test specimen load carrying ability due to the environmental attack. Analysis of breaking load data by extreme value statistics enables the calculation of survival probabilities and a statistically defined threshold stress applicable to the specific test conditions. A fracture mechanics model is given which quantifies depth of attack in the stress corroded specimen by an effective flaw size calculated from the breaking stress and the material strength and fracture toughness properties. Comparisons are made with experimental results from three tempers of 7075 alloy plate tested by the breaking load method and by traditional tests of statistically loaded smooth tension bars and conventional precracked specimens.
Proppant flowback control additives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nguyen, P.D.; Weaver, J.D.; Parker, M.A.
1996-12-31
This paper describes the laboratory and field development of thermoplastic film materials used to reduce proppant flowback that can occur after fracturing treatments. The paper provides a summary of flowback mechanism theories and laboratory tests comparing flowback tendency for various types of treating procedures and materials. Some of these materials include angular proppant, proppant/fiber mixtures, and proppant with film strips tested over a wide range of temperature, closure stress, and flow-rate conditions. Field treatment procedures are discussed, and several case histories are presented. All of the methods evaluated were effective in reducing proppant flowback under certain conditions. Heat-shrink film cutmore » into thin slivers proved to provide flowback reduction over broad temperature and closure stress ranges and was found to cause little impairment to fracture conductivity with some dependency on use concentration, temperature, and closure stress. The film materials were more resistant to damage caused by blending and pumping than all other materials evaluated. In addition, proppant packs, including consolidated packs, were significantly more tolerant of large, repeated stress changes. Field results indicate that the use of the heat-shrink film material as a flowback control agent permits more aggressive bean-up procedures following conventional fracturing treatments. Conventional dry-additive metering systems were used to add the film material to the fracturing fluid proppant slurry.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jalaeian, Hamed, E-mail: hjalaeia@umn.edu; Talaie, Reza; D’Souza, Donna
PurposeThis study was performed to compare the intrahepatic shunt function outcome and procedural complications of minilaparotomy-assisted transmesenteric (MAT)-transjugular intrahepatic portosystemic shunt (TIPS) placement with the conventional transjugular method.MethodsThis is a retrospective review of all patients who had a MAT or conventional TIPS procedure over a 6-year period at our institute. The primary patency rate, fluoroscopy time, technical success, major procedure-related complications, and mortality data were compared between two treatment groups.ResultsWe included 49 patients with MAT-TIPS, and 63 with conventional TIPS, with an average follow-up of 21.43 months. The primary patency rates at 6 and 12 months were 82.9 and 66.7 % in themore » conventional TIPS group, and 81.0 and 76.5 % in the MAT-TIPS group (p = 1.000, and 0.529), respectively. There was no significant difference in technical success rate, post-procedure portosystemic pressure gradient, fluoroscopy time, and peri-procedural mortality rate between treatment groups. Major procedural-related complications were seen more frequently among MAT-TIPS patients (p = 0.012). In the MAT-TIPS group, 5 (10.2 %) patients developed post-procedure minilaparotomy, wound-related complications, and 5 (10.2 %) developed bacterial peritonitis; whereas, none of patients with conventional TIPS had either of these complications (p = 0.014).ConclusionWhile both MAT-TIPS and conventional TIPS had similar shunt primary patency rate and technical success rate, the MAT approach was associated with a significantly higher rate of minilaparotomy-related wound complications or infectious complications. These complications maybe prevented by a change in post-procedure monitoring and therapy.« less
Barros, Raquel R M; Novaes, Arthur B Júnior; Grisi, Márcio F M; Souza, Sérgio L S; Taba, Mário Júnior; Palioto, Daniela B
2004-10-01
The acellular dermal matrix graft (ADMG) has become widely used in periodontal surgeries as a substitute for the subepithelial connective tissue graft (SCTG). These grafts exhibit different healing processes due to their distinct cellular and vascular structures. Therefore the surgical technique primarily developed for the autograft may not be adequate for the allograft. This study compared the clinical results of two surgical techniques--the "conventional" and a modified procedure--for the treatment of localized gingival recessions with the ADMG. A total of 32 bilateral Miller Class I or II gingival recessions were selected and randomly assigned to test and control groups. The control group received the SCTG and the test group the modified surgical technique. Probing depth (PD), relative clinical attachment level (RCAL), gingival recession (GR), and width of keratinized tissue (KT) were measured 2 weeks prior to surgery and 6 months post-surgery. Both procedures improved all the evaluated parameters after 6 months. Comparisons between the groups by Mann-Whitney rank sum test revealed no statistically significant differences in terms of CAL gain, PD reduction, and increase in KT from baseline to 6-month evaluation. However, there was a statistically significant greater reduction of GR favoring the modified technique (P = 0.002). The percentage of root coverage was 79% for the test group and 63.9% for the control group. We conclude that the modified technique is more suitable for root coverage procedures with the ADMG since it had statistically significant better clinical results compared to the traditional technique.
Effects of Mid-Level Ethanol Blends on Conventional Vehicle Emissions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knoll, K.; West, B.; Huff, S.
2010-06-01
Tests were conducted in 2008 on 16 late-model conventional vehicles (1999-2007) to determine short-term effects of mid-level ethanol blends on performance and emissions. Vehicle odometer readings ranged from 10,000 to 100,000 miles, and all vehicles conformed to federal emissions requirements for their federal certification level. The LA92 drive cycle, also known as the Unified Cycle, was used for testing because it more accurately represents real-world acceleration rates and speeds than the Federal Test Procedure. Test fuels were splash-blends of up to 20 volume percent ethanol with federal certification gasoline. Both regulated and unregulated air-toxic emissions were measured. For the 16-vehiclemore » fleet, increasing ethanol content resulted in reductions in average composite emissions of both nonmethane hydrocarbons and carbon monoxide and increases in average emissions of ethanol and aldehydes.« less
Galvín, Adela P; Ayuso, Jesús; Barbudo, Auxi; Cabrera, Manuel; López-Uceda, Antonio; Rosales, Julia
2017-12-27
In general terms, plant managers of sites producing construction wastes assess materials according to concise, legally recommended leaching tests that do not consider the compaction stage of the materials when they are applied on-site. Thus, the tests do not account for the real on-site physical conditions of the recycled aggregates used in civil works (e.g., roads or embankments). This leads to errors in estimating the pollutant potential of these materials. For that reason, in the present research, an experimental procedure is designed as a leaching test for construction materials under compaction. The aim of this laboratory test (designed specifically for the granular materials used in civil engineering infrastructures) is to evaluate the release of pollutant elements when the recycled aggregate is tested at its commercial grain-size distribution and when the material is compacted under on-site conditions. Two recycled aggregates with different gypsum contents (0.95 and 2.57%) were used in this study. In addition to the designed leaching laboratory test, the conventional compliance leaching test and the Dutch percolation test were performed. The results of the new leaching method were compared with the conventional leaching test results. After analysis, the chromium and sulphate levels obtained from the newly designed test were lower than those obtained from the conventional leaching test, and these were considered more seriously pollutant elements. This result confirms that when the leaching behaviour is evaluated for construction aggregates without density alteration, crushing the aggregate and using only the finest fraction, as is done in the conventional test (which is an unrealistic situation for aggregates that are applied under on-site conditions), the leaching behaviour is not accurately assessed.
Modified Brown-Forsythe Procedure for Testing Interaction Effects in Split-Plot Designs
ERIC Educational Resources Information Center
Vallejo, Guillermo; Ato, Manuel
2006-01-01
The standard univariate and multivariate methods are conventionally used to analyze continuous data from groups by trials repeated measures designs, in spite of being extremely sensitive to departures from the multisample sphericity assumption when group sizes are unequal. However, in the last 10 years several authors have offered alternative…
A Critical Comparison of Psychometric Models for Measuring Achievement. Methodology Project.
ERIC Educational Resources Information Center
Choppin, Bruce; And Others
A detailed description of five latent structure models of achievement measurement is presented. The first project paper, by David L. McArthur, analyzes the history of mental testing to show how conventional item analysis procedures were developed, and how dissatisfaction with them has led to fragmentation. The range of distinct conceptual and…
10 CFR 430.23 - Test procedures for the measurement of energy and water consumption.
Code of Federal Regulations, 2010 CFR
2010-01-01
... nearest dollar per year. (2) The energy efficiency ratio for room air conditioners, expressed in Btu's per... one-quarter of a dollar per year. (2) The cooking efficiency for conventional cooking tops... appendix I to this subpart. The final cooking efficiency values shall be rounded off to three significant...
Niro, A; Sborgia, G; Sborgia, A; Alessio, G
2018-01-17
The incidence of anterior ischemic optic neuropathy after coronary artery bypass graft procedures ranges from 1.3 to 0.25%. The mechanisms of anterior ischemic optic neuropathy after cardiovascular procedures remain undefined but many systemic and related-to-surgery risk factors could underlie anterior ischemic optic neuropathy. In this case, we report a rare presentation of a bilateral anterior ischemic optic neuropathy after coronary artery bypass graft and speculate on the preoperative hyperhomocysteinemia as an independent risk factor for anterior ischemic optic neuropathy. A 56-year-old white man, a tobacco smoker with type 2 diabetes and coronary artery disease, underwent a conventional coronary artery bypass graft with extracorporeal circulation. In spite of ongoing anti-aggregation, antithrombotic, and vasodilator therapy, 10 days after the surgery he complained of severe bilateral visual loss. Funduscopy and fluorescein angiography revealed a bilateral anterior ischemic optic neuropathy. Analysis of preoperative laboratory tests revealed hyperhomocysteinemia. Hyperhomocysteinemia could increase the risk of ocular vascular damage and bilateral ocular involvement in patients who have undergone conventional coronary artery bypass graft.
Rapid Detection and Identification of Respiratory Viruses by Direct Immunofluorescence
D'Alessio, Donn; Williams, Stanley; Dick, Elliot C.
1970-01-01
The use of fluorescein-conjugated antiserum against respiratory syncytial (RS) and parainfluenza 1 and 3 viruses was compared with conventional techniques in the rapid detection of virus in tissue cultures inoculated with pharyngeal specimens known to contain these viruses. Twenty-three specimens were tested: 9 RS, 8 parainfluenza 1, and 6 parainfluenza 3. The fluorescent-antibody technique (FA) detected virus in 52% of the tissue cultures in 24 hr, and, by 72 hr, 22 of the 23 cultures were FA-positive whereas only 5 were positive by conventional techniques. Additionally, conjugated antisera were prepared against herpes simplex, influenza A2, and adenovirus type 5. All conjugates stained only the homologous virus and were 100- to 10,000-fold more sensitive than conventional techniques in detecting descending dilutions of virus inocula by 24 hr. With the procedures described, several antisera could be conjugated and ready for use within 24 hr. Serum fractionation was by ammonium sulfate precipitation, and with the procedure outlined virtually complete recovery of the globulin fraction and elimination of all of the albumin were accomplished. Images PMID:4098101
Safety syringes and anti-needlestick devices in orthopaedic surgery.
Sibbitt, Wilmer L; Band, Philip A; Kettwich, Lawrence G; Sibbitt, Cristina R; Sibbitt, Lori J; Bankhurst, Arthur D
2011-09-07
The American Academy of Orthopaedic Surgery (AAOS), The Joint Commission, the Occupational Safety and Health Administration (OSHA), and the Needlestick Safety and Prevention Act encourage the integration of safety-engineered devices to prevent needlestick injuries to health-care workers and patients. We hypothesized that safety syringes and needles could be used in outpatient orthopaedic injection and aspiration procedures. The study investigated the orthopaedic uses and procedural idiosyncrasies of safety-engineered devices, including (1) four safety needles (Eclipse, SafetyGlide, SurGuard, and Magellan), (2) a mechanical safety syringe (RPD), (3) two automatic retractable syringes (Integra, VanishPoint), (4) three manual retractable syringes (Procedur-SF, Baksnap, Invirosnap), and (5) three shielded syringes (Safety-Lok, Monoject, and Digitally Activated Shielded [DAS] Syringe). The devices were first tested ex vivo, and then 1300 devices were used for 425 subjects undergoing outpatient arthrocentesis, intra-articular injections, local anesthesia, aspiration biopsy, and ultrasound-guided procedures. During the clinical observation, there were no accidental needlesticks (0 needlesticks per 1300 devices). Safety needles could be successfully used on a Luer syringe but were limited to ≤1.5 in (≤3.81 cm) in length and the shield could interfere with sonography. The mechanical safety syringes functioned well in all orthopaedic procedures. Automatic retractable syringes were too small for arthrocentesis of the knee, and the plunger blew out and prematurely collapsed with high-pressure injections. The manual retractable syringes and shielded syringes could be used with conventional needles for most orthopaedic procedures. The most effective and reliable safety devices for orthopaedic syringe procedures are shielded safety needles, mechanical syringes, manual retractable syringes, and shielded syringes, but not automatic retractable syringes. Even when adopting safety-engineered devices for an orthopaedic clinic, conventional syringes larger than 20 mL and conventional needles longer than 1.5 in (3.8 cm) are necessary.
Automated Smartphone Threshold Audiometry: Validity and Time Efficiency.
van Tonder, Jessica; Swanepoel, De Wet; Mahomed-Asmail, Faheema; Myburgh, Hermanus; Eikelboom, Robert H
2017-03-01
Smartphone-based threshold audiometry with automated testing has the potential to provide affordable access to audiometry in underserved contexts. To validate the threshold version (hearTest) of the validated hearScreen™ smartphone-based application using inexpensive smartphones (Android operating system) and calibrated supra-aural headphones. A repeated measures within-participant study design was employed to compare air-conduction thresholds (0.5-8 kHz) obtained through automated smartphone audiometry to thresholds obtained through conventional audiometry. A total of 95 participants were included in the study. Of these, 30 were adults, who had known bilateral hearing losses of varying degrees (mean age = 59 yr, standard deviation [SD] = 21.8; 56.7% female), and 65 were adolescents (mean age = 16.5 yr, SD = 1.2; 70.8% female), of which 61 had normal hearing and the remaining 4 had mild hearing losses. Threshold comparisons were made between the two test procedures. The Wilcoxon signed-ranked test was used for comparison of threshold correspondence between manual and smartphone thresholds and the paired samples t test was used to compare test time. Within the adult sample, 94.4% of thresholds obtained through smartphone and conventional audiometry corresponded within 10 dB or less. There was no significant difference between smartphone (6.75-min average, SD = 1.5) and conventional audiometry test duration (6.65-min average, SD = 2.5). Within the adolescent sample, 84.7% of thresholds obtained at 0.5, 2, and 4 kHz with hearTest and conventional audiometry corresponded within ≤5 dB. At 1 kHz, 79.3% of the thresholds differed by ≤10 dB. There was a significant difference (p < 0.01) between smartphone (7.09 min, SD = 1.2) and conventional audiometry test duration (3.23 min, SD = 0.6). The hearTest application with calibrated supra-aural headphones provides a cost-effective option to determine valid air-conduction hearing thresholds. American Academy of Audiology
Geminiani, Alessandro; Weitz, Daniel S; Ercoli, Carlo; Feng, Changyong; Caton, Jack G; Papadimitriou, Dimitrios E V
2015-04-01
Sonic instruments may reduce perforation rates of the schneiderian membrane during lateral window sinus augmentation procedures. This study compares the incidence of membrane perforations using a sonic handpiece with an oscillating diamond insert versus a turbine handpiece with a conventional rotary diamond stone during lateral window sinus augmentation procedures. A retrospective chart analysis identified all lateral window sinus augmentation procedures done during a defined period. Among these procedures, those performed with a sonic handpiece and an oscillating diamond insert (experimental) and those performed with a conventional turbine and rotary diamond stone (conventional) were selected for this study. Reported occurrences of sinus membrane perforations during preparation of the osteotomy and elevation of the sinus membrane, as well as postoperative complications, were recorded and compared between treatment groups. Ninety-three consecutive patients were identified for a total of 130 sinus augmentation procedures (51 conventional, 79 experimental). Schneiderian membrane perforations were noted during preparation of the lateral window osteotomy in 27.5% of the sinuses in the conventional group and 12.7% of sinuses in the experimental group. During membrane elevation, perforations were noted in 43.1% of the sinuses in the conventional group and 25.3% of sinuses in the experimental group. Both differences in perforation rates were statistically significant (p < .05). There was no statistically significant difference in postoperative complications. In this study, the use of a sonic instrument to prepare the lateral window osteotomy during sinus elevation procedures resulted in a reduced perforation rate of the Schneiderian membrane compared with the conventional turbine instrument. © 2013 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Sprowls, D. O.
1984-01-01
A review of the literature is presented with the objectives of identifying relationships between various accelerated stress corrosion testing techniques, and for determining the combination of test methods best suited to selection and design of high strength aluminum alloys. The following areas are reviewed: status of stress-corrosion test standards, the influence of mechanical and environmental factors on stress corrosion testing, correlation of accelerated test data with in-service experience, and procedures used to avoid stress corrosion problems in service. Promising areas for further work are identified.
Engelen, Bert; Meinken, Kristin; von Wintzingerode, Friedrich; Heuer, Holger; Malkomes, Hans-Peter; Backhaus, Horst
1998-01-01
Herbogil (dinoterb), a reference herbicide, the mineral oil Oleo (paraffin oil used as an additive to herbicides), and Goltix (metamitron) were taken as model compounds for the study of impacts on microbial soil communities. After the treatment of soil samples, effects on metabolic sum parameters were determined by monitoring substrate-induced respiration (SIR) and dehydrogenase activity, as well as carbon and nitrogen mineralization. These conventional ecotoxicological testing procedures are used in pesticide registration. Inhibition of biomass-related activities and stimulation of nitrogen mineralization were the most significant effects caused by the application of Herbogil. Even though Goltix and Oleo were used at a higher dosage (10 times higher), the application of Goltix resulted in smaller effects and the additive Oleo was the least-active compound, with minor stimulation of test parameters at later observation times. The results served as a background for investigation of the power of “fingerprinting” methods in microbial ecology. Changes in catabolic activities induced by treatments were analyzed by using the 95 carbon sources provided by the BIOLOG system. Variations in the complex metabolic fingerprints demonstrated inhibition of many catabolic pathways after the application of Herbogil. Again, the effects of the other compounds were expressed at much lower levels and comprised stimulations as well as inhibitions. Testing for significance by a multivariate t test indicated that the sensitivity of this method was similar to the sensitivities of the conventional testing procedures. The variation of sensitive carbon sources, as determined by factor weights at different observation times, indicated the dynamics of the community shift induced by the Herbogil treatment in more detail. DNA extractions from soil resulted in a collection of molecules representing the genetic composition of total bacterial communities. Distinct and highly reproducible community patterns, or genetic fingerprints, resulting from application of the different herbicides were obtained by the sequence-specific separation of partial 16S rDNA amplification products in temperature gradient gel electrophoresis. Significant pattern variations were quantified. For detailed analysis, application-responsive bands from the Herbogil and Oleo treatments were sequenced and their tentative phylogenetic positions were identified. Data interpretation and the potentials and biases of the additional observation windows on microbial communities are discussed. PMID:9687435
Arnold, Heino; Stukenborg-Colsman, Christina; Hurschler, Christof; Seehaus, Frank; Bobrowitsch, Evgenij; Waizy, Hazibullah
2012-01-01
The aim of this study was to examine resistance to angulation and displacement of the internal fixation of a proximal first metatarsal lateral displacement osteotomy, using a locking plate system compared with a conventional crossed screw fixation. Seven anatomical human specimens were tested. Each specimen was tested with a locking screw plate as well as a crossed cancellous srew fixation. The statistical analysis was performed by the Friedman test. The level of significance was p = 0.05. We found larger stability about all three axes of movement analyzed for the PLATE than the crossed screws osteosynthesis (CSO). The Friedman test showed statistical significance at a level of p = 0.05 for all groups and both translational and rotational movements. The results of our study confirm that the fixation of the lateral proximal first metatarsal displacement osteotomy with a locking plate fixation is a technically simple procedure of superior stability.
Arnold, Heino; Stukenborg-Colsman, Christina; Hurschler, Christof; Seehaus, Frank; Bobrowitsch, Evgenij; Waizy, Hazibullah
2012-01-01
Introduction: The aim of this study was to examine resistance to angulation and displacement of the internal fixation of a proximal first metatarsal lateral displacement osteotomy, using a locking plate system compared with a conventional crossed screw fixation. Materials and Methodology: Seven anatomical human specimens were tested. Each specimen was tested with a locking screw plate as well as a crossed cancellous srew fixation. The statistical analysis was performed by the Friedman test. The level of significance was p = 0.05. Results: We found larger stability about all three axes of movement analyzed for the PLATE than the crossed screws osteosynthesis (CSO). The Friedman test showed statistical significance at a level of p = 0.05 for all groups and both translational and rotational movements. Conclusion: The results of our study confirm that the fixation of the lateral proximal first metatarsal displacement osteotomy with a locking plate fixation is a technically simple procedure of superior stability. PMID:22675409
Strain controlled cyclic tests on miniaturized specimens
NASA Astrophysics Data System (ADS)
Procházka, R.; Džugan, J.
2017-02-01
The paper is dealing with strain controlled cyclic tests using a non-contact strain measurement based on digital image correlation techniques on proportional sizes of conventional specimens. The cyclic behaviour of 34CrNiMo6 high-strength steel was investigated on miniaturized round specimens with diameter of 2mm that were compared with specimens in accordance with ASTM E606 standards. The cycle asymmetry coefficient was R= -1. This application is intended to be used for life time assessment of in service components in future work which enables to carried out a group of mechanical tests from a limited amount of the experimental material. The attention was paid to confirm the suitability of the proposed size miniaturization geometry, testing set up and procedure. The test results obtained enabled to construct Manson-Coffin curves and assess fatigue parameters. The purpose of this study is to present differences between cyclic curves and cyclic parameters which have been evaluated based on conventional and miniaturized specimens.
Enhancing lineup identification accuracy: two codes are better than one.
Melara, R D; DeWitt-Rickards, T S; O'Brien, T P
1989-10-01
Ways of improving identification accuracy were explored by comparing the conventional visual lineup with an auditory/visual lineup, one that paired color photographs with voice recordings. This bimodal lineup necessitated sequential presentation of lineup members; Experiment 1 showed that performance in sequential lineups was better than performance in traditional simultaneous lineups. In Experiments 2A and 2B unimodal and bimodal lineups were compared by using a multiple-lineup paradigm: Ss viewed 3 videotaped episodes depicting standard police procedures and were tested in 4 sequential lineups. Bimodal lineups were more diagnostic than either visual or auditory lineups alone. The bimodal lineup led to a 126% improvement in number of correct identifications over the conventional visual lineup, with no concomitant increase in number of false identifications. These results imply strongly that bimodal procedures should be adopted in real-world lineups. The nature of memorial processes underlying this bimodal advantage is discussed.
NASA Technical Reports Server (NTRS)
Edwardo, H. A.; Moulis, F. R.; Merry, C. J.; Mckim, H. L.; Kerber, A. G.; Miller, M. A.
1985-01-01
The Pittsburgh District, Corps of Engineers, has conducted feasibility analyses of various procedures for performing flood damage assessments along the main stem of the Ohio River. Procedures using traditional, although highly automated, techniques and those based on geographic information systems have been evaluated at a test site, the City of New Martinsville, Wetzel County, WV. The flood damage assessments of the test site developed from an automated, conventional structure-by-structure appraisal served as the ground truth data set. A geographic information system was developed for the test site which includes data on hydraulic reach, ground and reference flood elevations, and land use/cover. Damage assessments were made using land use mapping developed from an exhaustive field inspection of each tax parcel. This ground truth condition was considered to provide the best comparison of flood damages to the conventional approach. Also, four land use/cover data sets were developed from Thematic Mapper Simulator (TMS) and Landsat-4 Thematic Mapper (TM) data. One of these was also used to develop a damage assessment of the test site. This paper presents the comparative absolute and relative accuracies of land use/cover mapping and flood damage assessments, and the recommended role of geographic information systems aided by remote sensing for conducting flood damage assessments and updates along the main stem of the Ohio River.
Gattol, Valentin; Sääksjärvi, Maria; Carbon, Claus-Christian
2011-01-01
Background The authors present a procedural extension of the popular Implicit Association Test (IAT; [1]) that allows for indirect measurement of attitudes on multiple dimensions (e.g., safe–unsafe; young–old; innovative–conventional, etc.) rather than on a single evaluative dimension only (e.g., good–bad). Methodology/Principal Findings In two within-subjects studies, attitudes toward three automobile brands were measured on six attribute dimensions. Emphasis was placed on evaluating the methodological appropriateness of the new procedure, providing strong evidence for its reliability, validity, and sensitivity. Conclusions/Significance This new procedure yields detailed information on the multifaceted nature of brand associations that can add up to a more abstract overall attitude. Just as the IAT, its multi-dimensional extension/application (dubbed md-IAT) is suited for reliably measuring attitudes consumers may not be consciously aware of, able to express, or willing to share with the researcher [2], [3]. PMID:21246037
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Xiang; Sokolov, Mikhail A; Nanstad, Randy K
Material fracture toughness in the fully ductile region can be described by a J-integral vs. crack growth resistance curve (J-R curve). As a conventional J-R curve measurement method, the elastic unloading compliance (EUC) method becomes impractical for elevated temperature testing due to relaxation of the material and friction induced back-up shape of the J-R curve. One alternative solution of J-R curve testing applies the Direct Current Potential Drop (DCPD) technique for measuring crack extension. However, besides crack growth, potential drop can also be influenced by plastic deformation, crack tip blunting, etc., and uncertainties exist in the current DCPD methodology especiallymore » in differentiating potential drop due to stable crack growth and due to material deformation. Thus, using DCPD for J-R curve determination remains a challenging task. In this study, a new adjustment procedure for applying DCPD to derive the J-R curve has been developed for conventional fracture toughness specimens, including compact tension, three-point bend, and disk-shaped compact specimens. Data analysis has been performed on Oak Ridge National Laboratory (ORNL) and American Society for Testing and Materials (ASTM) interlaboratory results covering different specimen thicknesses, test temperatures, and materials, to evaluate the applicability of the new DCPD adjustment procedure for J-R curve characterization. After applying the newly-developed procedure, direct comparison between the DCPD method and the normalization method on the same specimens indicated close agreement for the overall J-R curves, as well as the provisional values of fracture toughness near the onset of ductile crack extension, Jq, and of tearing modulus.« less
Development of subminiature multi-sensor hot-wire probes
NASA Technical Reports Server (NTRS)
Westphal, Russell V.; Ligrani, Phillip M.; Lemos, Fred R.
1988-01-01
Limitations on the spatial resolution of multisensor hot wire probes have precluded accurate measurements of Reynolds stresses very near solid surfaces in wind tunnels and in many practical aerodynamic flows. The fabrication, calibration and qualification testing of very small single horizontal and X-array hot-wire probes which are intended to be used near solid boundaries in turbulent flows where length scales are particularly small, is described. Details of the sensor fabrication procedure are reported, along with information needed to successfully operate the probes. As compared with conventional probes, manufacture of the subminiature probes is more complex, requiring special equipment and careful handling. The subminiature probes tested were more fragile and shorter lived than conventional probes; they obeyed the same calibration laws but with slightly larger experimental uncertainty. In spite of these disadvantages, measurements of mean statistical quantities and spectra demonstrate the ability of the subminiature sensors to provide the measurements in the near wall region of turbulent boundary layers that are more accurate than conventional sized probes.
Lakshmi, Rajagopalan; Ramachandran, Ranjani; Kumar, D Ravi; Sundar, A Syam; Radhika, G; Rahman, Fathima; Selvakumar, N; Kumar, Vanaja
2015-11-01
Increase in the isolation of drug resistant phenotypes of Mycobacterium tuberculosis necessitates accuracy in the testing methodology. Critical concentration defining resistance for ethionamide (ETO), needs re-evaluation in accordance with the current scenario. Thus, re-evaluation of conventional minimum inhibitory concentration (MIC) and proportion sensitivity testing (PST) methods for ETO was done to identify the ideal breakpoint concentration defining resistance. Isolates of M. tuberculosis (n=235) from new and treated patients were subjected to conventional MIC and PST methods for ETO following standard operating procedures. With breakpoint concentration set at 114 and 156 µg/ml, an increase in specificity was observed whereas sensitivity was high with 80 µg/ml as breakpoint concentration. Errors due to false resistant and susceptible isolates were least at 80 µg/ml concentration. Performance parameters at 80 µg/ml breakpoint concentration indicated significant association between PST and MIC methods.
Delayed flap approach procedures for noise abatement and fuel conservation
NASA Technical Reports Server (NTRS)
Edwards, F. G.; Bull, J. S.; Foster, J. D.; Hegarty, D. M.; Drinkwater, F. J., III
1976-01-01
The NASA/Ames Research Center is currently investigating the delayed flap approach during which pilot actions are determined and prescribed by an onboard digital computer. The onboard digital computer determines the proper timing for the deployment of the landing gear and flaps based on the existing winds and airplane gross weight. Advisory commands are displayed to the pilot. The approach is flown along the conventional ILS glide slope but is initiated at a higher airspeed and in a clean aircraft configuration that allows for low thrust and results in reduced noise and fuel consumption. Topics discussed include operational procedures, pilot acceptability of these procedures, and fuel/noise benefits resulting from flight tests and simulation.
Artificial intelligence and expert systems in-flight software testing
NASA Technical Reports Server (NTRS)
Demasie, M. P.; Muratore, J. F.
1991-01-01
The authors discuss the introduction of advanced information systems technologies such as artificial intelligence, expert systems, and advanced human-computer interfaces directly into Space Shuttle software engineering. The reconfiguration automation project (RAP) was initiated to coordinate this move towards 1990s software technology. The idea behind RAP is to automate several phases of the flight software testing procedure and to introduce AI and ES into space shuttle flight software testing. In the first phase of RAP, conventional tools to automate regression testing have already been developed or acquired. There are currently three tools in use.
Enhancement of Aviation Fuel Thermal Stability Characterization Through Application of Ellipsometry
NASA Technical Reports Server (NTRS)
Browne, Samuel Tucker; Wong, Hubert; Hinderer, Cameron Branch; Klettlinger, Jennifer
2012-01-01
ASTM D3241/Jet Fuel Thermal Oxidation Tester (JFTOT) procedure, the standard method for testing thermal stability of conventional aviation turbine fuels is inherently limited due to the subjectivity in the color standard for tube deposit rating. Quantitative assessment of the physical characteristics of oxidative fuel deposits provides a more powerful method for comparing the thermal oxidation stability characteristics of fuels, especially in a research setting. We propose employing a Spectroscopic Ellipsometer to determine the film thickness and profile of oxidative fuel deposits on JFTOT heater tubes. Using JP-8 aviation fuel and following a modified ASTM D3241 testing procedure, the capabilities of the Ellipsometer will be demonstrated by measuring oxidative fuel deposit profiles for a range of different deposit characteristics. The testing completed in this report was supported by the NASA Fundamental Aeronautics Subsonics Fixed Wing Project
QUEST+: A general multidimensional Bayesian adaptive psychometric method.
Watson, Andrew B
2017-03-01
QUEST+ is a Bayesian adaptive psychometric testing method that allows an arbitrary number of stimulus dimensions, psychometric function parameters, and trial outcomes. It is a generalization and extension of the original QUEST procedure and incorporates many subsequent developments in the area of parametric adaptive testing. With a single procedure, it is possible to implement a wide variety of experimental designs, including conventional threshold measurement; measurement of psychometric function parameters, such as slope and lapse; estimation of the contrast sensitivity function; measurement of increment threshold functions; measurement of noise-masking functions; Thurstone scale estimation using pair comparisons; and categorical ratings on linear and circular stimulus dimensions. QUEST+ provides a general method to accelerate data collection in many areas of cognitive and perceptual science.
Energy management - The delayed flap approach
NASA Technical Reports Server (NTRS)
Bull, J. S.
1976-01-01
Flight test evaluation of a Delayed Flap approach procedure intended to provide reductions in noise and fuel consumption is underway using the NASA CV-990 test aircraft. Approach is initiated at a high airspeed (240 kt) and in a drag configuration that allows for low thrust. The aircraft is flown along the conventional ILS glide slope. A Fast/Slow message display signals the pilot when to extend approach flaps, landing gear, and land flaps. Implementation of the procedure in commercial service may require the addition of a DME navigation aid co-located with the ILS glide slope transmitter. The Delayed Flap approach saves 250 lb of fuel over the Reduced Flap approach, with a 95 EPNdB noise contour only 43% as large.
Martini, Giorgio; Paffumi, Elena; De Gennaro, Michele; Mellios, Giorgos
2014-07-15
This paper presents an evaluation of the European type-approval test procedure for evaporative emissions from passenger cars based on real-world mobility data. The study relies on two large databases of driving patterns from conventional fuel vehicles collected by means of on-board GPS systems in the Italian provinces of Modena and Firenze. Approximately 28,000 vehicles were monitored, corresponding to approximately 36 million kilometres over a period of one month. The driving pattern of each vehicle was processed to derive the relation between trip length and parking duration, and the rate of occurrence of parking events against multiple evaporative cycles, defined on the basis of the type-approval test procedure as 12-hour diurnal time windows. These results are used as input for an emission simulation model, which calculates the total evaporative emissions given the characteristics of the evaporative emission control system of the vehicle and the ambient temperature conditions. The results suggest that the evaporative emission control system, fitted to the vehicles from Euro 3 step and optimised for the current type-approval test procedure, could not efficiently work under real-world conditions, resulting in evaporative emissions well above the type-approval limit, especially for small size vehicles and warm climate conditions. This calls for a revision of the type-approval test procedure in order to address real-world evaporative emissions. Copyright © 2014. Published by Elsevier B.V.
Schuller, P; Walling, D E; Sepúlveda, A; Trumper, R E; Rouanet, J L; Pino, I; Castillo, A
2004-05-01
Intensification of agricultural production in south-central Chile since the 1970s has caused problems of increased soil erosion and associated soil degradation. These problems have prompted a shift from conventional tillage to no-till management practices. Faced with the need to establish the impact of this shift in soil management on rates of soil loss, the use of caesium-137 (137Cs) measurements has been explored. A novel procedure for using measurements of the 137Cs depth distribution to estimate rates of soil loss at a sampling point under the original conventional tillage and after the shift to no-till management has been developed. This procedure has been successfully applied to a study site at Buenos Aires farm near Carahue in the 9th region of Chile. The results obtained indicate that the shift from conventional tillage to no-till management has caused net rates of soil loss to decrease to about 40% of those existing under conventional tillage. This assessment of the impact of introducing no-till management at the study site must, however, be seen as provisional, since only a limited number of sampling points were used. A simplified procedure aimed at documenting the reduction in erosion rates at additional sampling points, based solely on measurements of the 137Cs inventory of bulk cores and the 137Cs activity in the upper part of the soil has been developed and successfully tested at the study site. Previous application of 137Cs measurements to estimate erosion rates has been limited to estimation of medium-term erosion rates during the period extending from the beginning of fallout receipt to the time of sampling. The procedures described in this paper, which permits estimation of the change in erosion rates associated with a shift in land management practices, must be seen as representing a novel application of 137Cs measurements in soil erosion investigations.
Development of an integrated electrochemical system for in vitro yeast viability testing.
Adami, Andrea; Ress, Cristina; Collini, Cristian; Pedrotti, Severino; Lorenzelli, Leandro
2013-02-15
This work describes the development and testing of a microfabricated sensor for rapid cell growth monitoring, especially focused on yeast quality assessment for wine applications. The device consists of a NMOS ISFET sensor with Si(3)N(4) gate, able to indirectly monitor extracellular metabolism through pH variation of the medium, and a solid-state reference electrode implemented with PVC membranes doped with lipophilic salts (tetrabutylammonium-tetrabutylborate (TBA-TBB) and Potassium tetrakis(4-chlorphenyl)borate (KTClpB)). The use of a solid state reference electrode enables the implementation of a large number of cell assays in parallel, without the need of external conventional reference electrodes. Microbial growth testing has been performed both in standard culture conditions and on chip at different concentrations of ethanol in order to carry out a commonly used screening of wine yeast strains. Cell growth tests can be performed in few hours, providing a fast, sensitive and low cost analysis with respect to the conventional procedures. Copyright © 2012 Elsevier B.V. All rights reserved.
A Procedure to Detect Item Bias Present Simultaneously in Several Items
1991-04-25
exhibit a coherent and major biasing influence at the test level. In partic- ular, this can be true even if each individual item displays only a minor...response functions (IRFs) without the use of item parameter estimation algorithms when the sample size is too small for their use. Thissen, Steinberg...convention). A random sample of examinees is drawn from each group, and a test of N items is administered to them. Typically it is suspected that a
Alex, Deepa; Shetty, Y Bharath; Miranda, Glynis Anita; Prabhu, M Bharath; Karkera, Reshma
2015-01-01
Conventional investing and casting techniques are time-consuming and usually requires 2-4 h for completion. Accelerated nonstandard, casting techniques have been reported to achieve similar quality results in significantly less time, namely, in 30-40 min. During casting, it is essential to achieve compensation for the shrinkage of solidifying alloy by investment expansion. The metal casting ring restricts the thermal expansion of investment because the thermal expansion of the ring is lesser than that of the investment. The use of casting ring was challenged with the introduction of the ringless technique. A total of 40 test samples of nickel chromium (Ni-Cr) cast copings were obtained from the patterns fabricated using inlay casting wax. The 20 wax patterns were invested using metal ring and 20 wax patterns were invested using the ringless investment system. Of both the groups, 10 samples underwent conventional casting, and the other 10 underwent accelerated casting. The patterns were casted using the induction casting technique. All the test samples of cast copings were evaluated for vertical marginal gaps at four points on the die employing a stereo optical microscope. The vertical marginal discrepancy data obtained were tabulated. Mean and standard deviations were obtained. Vertical discrepancies were analyzed using analysis of variance and Tukey honestly significantly different. The data obtained were found to be very highly significant (P < 0.001). Mean vertical gap was the maximum for Group II (53.64 μm) followed by Group IV (47.62 μm), Group I (44.83 μm) and Group III (35.35 μm). The Ni-Cr cast copings fabricated with the conventional casting using ringless investment system showed significantly better marginal fit than that of cast copings fabricated from conventional and accelerated casting with metal ring investment and accelerated casting using ringless investment since those copings had shown the least vertical marginal discrepancies among the four methods evaluated in this study.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-30
... Surface efficiency deviation interval technology unit % % ( ) % Large A Electric Coil... 1 69.79 1.59 1.97... Surface efficiency deviation interval technology unit % % ( ) % Large A Electric Coil... 1 64.52 0.87 1.08... technology unit % % ( ) % Large A Electric Coil... 1 79.81 1.66 2.06 B Electric........ 1 61.81 2.83 3.52...
ERIC Educational Resources Information Center
Roberts, Laura; Mancuso, Steven V.
2014-01-01
This mixed-methods study of 84 job advertisements for international school leaders on six continents from 2006 to 2012 entailed both qualitative and quantitative research methods. Job advertisements were obtained from the most active recruiting agency for school leaders worldwide. Conventional and summative content analysis procedures were used to…
Realistic Vascular Replicator for TAVR Procedures.
Rotman, Oren M; Kovarovic, Brandon; Sadasivan, Chander; Gruberg, Luis; Lieber, Baruch B; Bluestein, Danny
2018-04-13
Transcatheter aortic valve replacement (TAVR) is an over-the-wire procedure for treatment of severe aortic stenosis (AS). TAVR valves are conventionally tested using simplified left heart simulators (LHS). While those provide baseline performance reliably, their aortic root geometries are far from the anatomical in situ configuration, often overestimating the valves' performance. We report on a novel benchtop patient-specific arterial replicator designed for testing TAVR and training interventional cardiologists in the procedure. The Replicator is an accurate model of the human upper body vasculature for training physicians in percutaneous interventions. It comprises of fully-automated Windkessel mechanism to recreate physiological flow conditions. Calcified aortic valve models were fabricated and incorporated into the Replicator, then tested for performing TAVR procedure by an experienced cardiologist using the Inovare valve. EOA, pressures, and angiograms were monitored pre- and post-TAVR. A St. Jude mechanical valve was tested as a reference that is less affected by the AS anatomy. Results in the Replicator of both valves were compared to the performance in a commercial ISO-compliant LHS. The AS anatomy in the Replicator resulted in a significant decrease of the TAVR valve performance relative to the simplified LHS, with EOA and transvalvular pressures comparable to clinical data. Minor change was seen in the mechanical valve performance. The Replicator showed to be an effective platform for TAVR testing. Unlike a simplified geometric anatomy LHS, it conservatively provides clinically-relevant outcomes and complement it. The Replicator can be most valuable for testing new valves under challenging patient anatomies, physicians training, and procedural planning.
Kashif, Muhammad; Andersson, Claes; Åberg, Magnus; Nygren, Peter; Sjöblom, Tobias; Hammerling, Ulf; Larsson, Rolf; Gustafsson, Mats G
2014-07-01
For decades, the standard procedure when screening for candidate anticancer drug combinations has been to search for synergy, defined as any positive deviation from trivial cases like when the drugs are regarded as diluted versions of each other (Loewe additivity), independent actions (Bliss independence), or no interaction terms in a response surface model (no interaction). Here, we show that this kind of conventional synergy analysis may be completely misleading when the goal is to detect if there is a promising in vitro therapeutic window. Motivated by this result, and the fact that a drug combination offering a promising therapeutic window seldom is interesting if one of its constituent drugs can provide the same window alone, the largely overlooked concept of therapeutic synergy (TS) is reintroduced. In vitro TS is said to occur when the largest therapeutic window obtained by the best drug combination cannot be achieved by any single drug within the concentration range studied. Using this definition of TS, we introduce a procedure that enables its use in modern massively parallel experiments supported by a statistical omnibus test for TS designed to avoid the multiple testing problem. Finally, we suggest how one may perform TS analysis, via computational predictions of the reference cell responses, when only the target cell responses are available. In conclusion, the conventional error-prone search for promising drug combinations may be improved by replacing conventional (toxicology-rooted) synergy analysis with an analysis focused on (clinically motivated) TS. ©2014 American Association for Cancer Research.
NASA Technical Reports Server (NTRS)
Sprowls, D. O.; Shumaker, M. B.; Walsh, J. D.; Coursen, J. W.
1973-01-01
Stress corrosion cracking (SSC) tests were performed on 13 aluminum alloys, 13 precipitation hardening stainless steels, and two titanium 6Al-4V alloy forgings to compare fracture mechanics techniques with the conventional smooth specimen procedures. Commercially fabricated plate and rolled or forged bars 2 to 2.5-in. thick were tested. Exposures were conducted outdoors in a seacoast atmosphere and in an inland industrial atmosphere to relate the accelerated tests with service type environments. With the fracture mechanics technique tests were made chiefly on bolt loaded fatigue precracked compact tension specimens of the type used for plane-strain fracture toughness tests. Additional tests of the aluminum alloy were performed on ring loaded compact tension specimens and on bolt loaded double cantilever beams. For the smooth specimen procedure 0.125-in. dia. tensile specimens were loaded axially in constant deformation type frames. For both aluminum and steel alloys comparative SCC growth rates obtained from tests of precracked specimens provide an additional useful characterization of the SCC behavior of an alloy.
Surgical bedside master console for neurosurgical robotic system.
Arata, Jumpei; Kenmotsu, Hajime; Takagi, Motoki; Hori, Tatsuya; Miyagi, Takahiro; Fujimoto, Hideo; Kajita, Yasukazu; Hayashi, Yuichiro; Chinzei, Kiyoyuki; Hashizume, Makoto
2013-01-01
We are currently developing a neurosurgical robotic system that facilitates access to residual tumors and improves brain tumor removal surgical outcomes. The system combines conventional and robotic surgery allowing for a quick conversion between the procedures. This concept requires a new master console that can be positioned at the surgical bedside and be sterilized. The master console was developed using new technologies, such as a parallel mechanism and pneumatic sensors. The parallel mechanism is a purely passive 5-DOF (degrees of freedom) joystick based on the author's haptic research. The parallel mechanism enables motion input of conventional brain tumor removal surgery with a compact, intuitive interface that can be used in a conventional surgical environment. In addition, the pneumatic sensors implemented on the mechanism provide an intuitive interface and electrically isolate the tool parts from the mechanism so they can be easily sterilized. The 5-DOF parallel mechanism is compact (17 cm width, 19cm depth, and 15cm height), provides a 505,050 mm and 90° workspace and is highly backdrivable (0.27N of resistance force representing the surgical motion). The evaluation tests revealed that the pneumatic sensors can properly measure the suction strength, grasping force, and hand contact. In addition, an installability test showed that the master console can be used in a conventional surgical environment. The proposed master console design was shown to be feasible for operative neurosurgery based on comprehensive testing. This master console is currently being tested for master-slave control with a surgical robotic system.
Schulman, K A; Stadtmauer, E A; Reed, S D; Glick, H A; Goldstein, L J; Pines, J M; Jackman, J A; Suzuki, S; Styler, M J; Crilley, P A; Klumpp, T R; Mangan, K F; Glick, J H
2003-02-01
We performed an economic analysis of data from 180 women in a clinical trial of conventional-dose chemotherapy vs high-dose chemotherapy plus stem-cell transplantation for metastatic breast cancer responding to first-line chemotherapy. Data on resource use, including hospitalizations, medical procedures, medications, and diagnostic tests, were abstracted from subjects' clinical trial records. Resources were valued using the Medicare Fee Schedule for inpatient costs at one academic medical center and average wholesale prices for medications. Monthly costs were calculated and stratified by treatment group and clinical phase. Mean follow-up was 690 days in the transplantation group and 758 days in the conventional-dose chemotherapy group. Subjects in the transplantation group were hospitalized for more days (28.6 vs 17.8, P=0.0041) and incurred higher costs (US dollars 84055 vs US dollars 28169) than subjects receiving conventional-dose chemotherapy, with a mean difference of US dollars 55886 (95% CI, US dollars 47298-US dollars 63666). Sensitivity analyses resulted in cost differences between the treatment groups from US dollars 36528 to US dollars 75531. High-dose chemotherapy plus stem-cell transplantation resulted in substantial additional morbidity and costs at no improvement in survival. Neither the survival results nor the economic findings support the use of this procedure outside of the clinical trial setting.
An empirical Bayes approach for the Poisson life distribution.
NASA Technical Reports Server (NTRS)
Canavos, G. C.
1973-01-01
A smooth empirical Bayes estimator is derived for the intensity parameter (hazard rate) in the Poisson distribution as used in life testing. The reliability function is also estimated either by using the empirical Bayes estimate of the parameter, or by obtaining the expectation of the reliability function. The behavior of the empirical Bayes procedure is studied through Monte Carlo simulation in which estimates of mean-squared errors of the empirical Bayes estimators are compared with those of conventional estimators such as minimum variance unbiased or maximum likelihood. Results indicate a significant reduction in mean-squared error of the empirical Bayes estimators over the conventional variety.
Global harmonization of quality assurance naming conventions in radiation therapy clinical trials.
Melidis, Christos; Bosch, Walther R; Izewska, Joanna; Fidarova, Elena; Zubizarreta, Eduardo; Ulin, Kenneth; Ishikura, Satoshi; Followill, David; Galvin, James; Haworth, Annette; Besuijen, Deidre; Clark, Catharine H; Clark, Clark H; Miles, Elizabeth; Aird, Edwin; Weber, Damien C; Hurkmans, Coen W; Verellen, Dirk
2014-12-01
To review the various radiation therapy quality assurance (RTQA) procedures used by the Global Clinical Trials RTQA Harmonization Group (GHG) steering committee members and present the harmonized RTQA naming conventions by amalgamating procedures with similar objectives. A survey of the GHG steering committee members' RTQA procedures, their goals, and naming conventions was conducted. The RTQA procedures were classified as baseline, preaccrual, and prospective/retrospective data capture and analysis. After all the procedures were accumulated and described, extensive discussions took place to come to harmonized RTQA procedures and names. The RTQA procedures implemented within a trial by the GHG steering committee members vary in quantity, timing, name, and compliance criteria. The procedures of each member are based on perceived chances of noncompliance, so that the quality of radiation therapy planning and treatment does not negatively influence the trial measured outcomes. A comparison of these procedures demonstrated similarities among the goals of the various methods, but the naming given to each differed. After thorough discussions, the GHG steering committee members amalgamated the 27 RTQA procedures to 10 harmonized ones with corresponding names: facility questionnaire, beam output audit, benchmark case, dummy run, complex treatment dosimetry check, virtual phantom, individual case review, review of patients' treatment records, and protocol compliance and dosimetry site visit. Harmonized RTQA harmonized naming conventions, which can be used in all future clinical trials involving radiation therapy, have been established. Harmonized procedures will facilitate future intergroup trial collaboration and help to ensure comparable RTQA between international trials, which enables meta-analyses and reduces RTQA workload for intergroup studies. Copyright © 2014 Elsevier Inc. All rights reserved.
Higa, Rodrigo Hitoshi; Semenara, Nayara Thiago; Henriques, José Fernando Castanha; Janson, Guilherme; Sathler, Renata; Fernandes, Thais Maria Freire
2016-01-01
The aim of the study was to evaluate deflection forces of rectangular orthodontic wires in conventional (MorelliTM), active (In-Ovation RTM) and passive (Damon 3MXTM) self-ligating brackets. Two brands of stainless steel and nickel-titanium (NiTi) wires (MorelliTM and GACTM), in addition to OrmcoTM copper-nickel-titanium wires were used. Specimens were assembled in a clinical simulation device especially designed for this study and tested in an Instron universal testing machine. For the testing procedures, an acrylic structure representative of the maxillary right central incisor was lingually moved in activations of 0 to 1 mm, with readings of the force released by deflection in unloading of 0.5, 0.8 and 1 mm at a constant speed of 2 mm/min. Inter-bracket forces with stainless steel, NiTi and CuNiTi were individually compared by two-way ANOVA, followed by Tukey's tests. Results showed that there were lower forces in conventional brackets, followed by active and passive self-ligating brackets. Within the brands, only for NiTi wires, the MorelliTM brand presented higher forces than GACTM wires. Bracket systems provide different degrees of deflection force, with self-ligating brackets showing the highest forces.
Radiosurgical fistulotomy; an alternative to conventional procedure in fistula in ano.
Gupta, Pravin J
2003-01-01
Most surgeons continue to prefer the classic lay open technique [fistulotomy] as the gold standard of treatment in anal fistula. In this randomized study, a comparison is made between conventional fistulotomy and fistulotomy performed by a radio frequency device. One hundred patients of low anal fistula posted for fistulotomy were randomized prospectively to either a conventional or radio frequency technique. Parameters measured included time taken for the procedure, amount of blood loss, postoperative pain, return to work, and recurrence rate. The patient demographic was comparable in 2 groups. The radio frequency fistulotomy was quicker as compared to a conventional one [22 versus 37 minutes, p = 0.001], amount of bleeding was significantly less [47 ml versus 134 ml, p = 0.002], and hospital stay was less when patient was operated by radio frequency method [37 hours versus 56 hours in conventional method, p = 0.001]. The postoperative pain in the first 24 hours was more in conventional group [2 to 5 versus 0 to 3 on visual analogue scale]. The patients from radio frequency group resumed their duties early with a reduced healing period of the wounds [47 versus 64 days, p = 0.01]. The recurrence or failure rates were comparable in the radio frequency and conventional groups [2% versus 6%]. Fistulotomy procedure using a radio frequency technique has significant advantages over a conventional procedure with regard to operation time, blood loss, return to normal activity, and healing time of the wound.
Supercritical tests of a self-optimizing, variable-Camber wind tunnel model
NASA Technical Reports Server (NTRS)
Levinsky, E. S.; Palko, R. L.
1979-01-01
A testing procedure was used in a 16-foot Transonic Propulsion Wind Tunnel which leads to optimum wing airfoil sections without stopping the tunnel for model changes. Being experimental, the optimum shapes obtained incorporate various three-dimensional and nonlinear viscous and transonic effects not included in analytical optimization methods. The method is a closed-loop, computer-controlled, interactive procedure and employs a Self-Optimizing Flexible Technology wing semispan model that conformally adapts the airfoil section at two spanwise control stations to maximize or minimize various prescribed merit functions subject to both equality and inequality constraints. The model, which employed twelve independent hydraulic actuator systems and flexible skins, was also used for conventional testing. Although six of seven optimizations attempted were at least partially convergent, further improvements in model skin smoothness and hydraulic reliability are required to make the technique fully operational.
Identifying fMRI Model Violations with Lagrange Multiplier Tests
Cassidy, Ben; Long, Christopher J; Rae, Caroline; Solo, Victor
2013-01-01
The standard modeling framework in Functional Magnetic Resonance Imaging (fMRI) is predicated on assumptions of linearity, time invariance and stationarity. These assumptions are rarely checked because doing so requires specialised software, although failure to do so can lead to bias and mistaken inference. Identifying model violations is an essential but largely neglected step in standard fMRI data analysis. Using Lagrange Multiplier testing methods we have developed simple and efficient procedures for detecting model violations such as non-linearity, non-stationarity and validity of the common Double Gamma specification for hemodynamic response. These procedures are computationally cheap and can easily be added to a conventional analysis. The test statistic is calculated at each voxel and displayed as a spatial anomaly map which shows regions where a model is violated. The methodology is illustrated with a large number of real data examples. PMID:22542665
Shade matching assisted by digital photography and computer software.
Schropp, Lars
2009-04-01
To evaluate the efficacy of digital photographs and graphic computer software for color matching compared to conventional visual matching. The shade of a tab from a shade guide (Vita 3D-Master Guide) placed in a phantom head was matched to a second guide of the same type by nine observers. This was done for twelve selected shade tabs (tests). The shade-matching procedure was performed visually in a simulated clinic environment and with digital photographs, and the time spent for both procedures was recorded. An alternative arrangement of the shade tabs was used in the digital photographs. In addition, a graphic software program was used for color analysis. Hue, chroma, and lightness values of the test tab and all tabs of the second guide were derived from the digital photographs. According to the CIE L*C*h* color system, the color differences between the test tab and tabs of the second guide were calculated. The shade guide tab that deviated least from the test tab was determined to be the match. Shade matching performance by means of graphic software was compared with the two visual methods and tested by Chi-square tests (alpha= 0.05). Eight of twelve test tabs (67%) were matched correctly by the computer software method. This was significantly better (p < 0.02) than the performance of the visual shade matching methods conducted in the simulated clinic (32% correct match) and with photographs (28% correct match). No correlation between time consumption for the visual shade matching methods and frequency of correct match was observed. Shade matching assisted by digital photographs and computer software was significantly more reliable than by conventional visual methods.
Bhat, Pragathi Raghavendra; Acharya, Anirudh Balakrishna; Thakur, Srinath Lakshman
2016-01-01
The palatal approach of anterior superior alveolar (P-ASA) using WAND injection was reported to effectively provide a profound bilateral maxillary anesthesia of the soft tissue of anterior one-third of the palate and facial gingivae extending from canine to canine which lasted for more than an hour thus making it ideal for scaling root planing and minor periodontal procedures in the anterior maxilla. Our study suggests that the conventional P-ASA injection is of very short duration and the extent of anesthesia was not profound and consistent. This has not been reported earlier in the literature. Thirty-five cases (20 males and 15 females), who underwent scaling, root planing and minor periodontal surgical procedures such as abscess drainage, gingivectomy, and frenectomy in the maxillary anterior region in the age range of 19-45 years was assessed for the efficacy of the P-ASA injection. After the administration of the P-ASA injection, the subjective and the objective symptoms were used to evaluate the extent and duration of the anesthesia at 10, 15, and 20 min. This study suggests that the conventional P-ASA injection technique does not provide anesthesia for more than 20 min. Wilcoxon matched pairs test was used to compare the effect of anesthesia at the different time intervals and the results were found to be statistically significant ( P < 0.05). The conventional P-ASA injection technique is of very short duration and does not demonstrate effectiveness in periodontal surgery of the anterior maxilla.
5-inch-size liquid crystal flat panel display evaluation test by flight simulator
NASA Astrophysics Data System (ADS)
Kawahara, Hiroyasu; Watanabe, Akira; Wakairo, Kaoru; Udagawa, Tomoyuki; Kurihara, Yoichiro
An evaluation test is conducted on the function, performance, and display format of a 5x5 inch flat panel display (FPD) in a flight simulator. The FPD utilizes a color liquid crystal panel that is compact and lightweight and has excellent visibility. The simulator evaluation test is carried out in sequence with the conventional takeoff and landing to altitude, and then conversion to STOL procedures for flight path and subsequent approach and landing. It is shown that the liquid crystal display could be employed as a satisfactory indicator for aircraft instrumentation.
Clinical Applications of Gastrointestinal Manometry in Children
2014-01-01
Manometry is a noninvasive diagnostic tool for identifying motility dysfunction of the gastrointestinal tract. Despite the great technical advances in monitoring motility, performance of the study in pediatric patients has several limitations that should be considered during the procedure and interpretation of the test results. This article reviews the clinical applications of conventional esophageal and anorectal manometries in children by describing a technique for performing the test. This review will develop the uniformity required for the methods of performance, the parameters for measurement, and interpretation of test results that could be applied in pediatric clinical practice. PMID:24749084
Traceable measurements of the electrical parameters of solid-state lighting products
NASA Astrophysics Data System (ADS)
Zhao, D.; Rietveld, G.; Braun, J.-P.; Overney, F.; Lippert, T.; Christensen, A.
2016-12-01
In order to perform traceable measurements of the electrical parameters of solid-state lighting (SSL) products, it is necessary to technically adequately define the measurement procedures and to identify the relevant uncertainty sources. The present published written standard for SSL products specifies test conditions, but it lacks an explanation of how adequate these test conditions are. More specifically, both an identification of uncertainty sources and a quantitative uncertainty analysis are absent. This paper fills the related gap in the present written standard. New uncertainty sources with respect to conventional lighting sources are determined and their effects are quantified. It shows that for power measurements, the main uncertainty sources are temperature deviation, power supply voltage distortion, and instability of the SSL product. For current RMS measurements, the influence of bandwidth, shunt resistor, power supply source impedance and ac frequency flatness are significant as well. The measurement uncertainty depends not only on the test equipment but is also a function of the characteristics of the device under test (DUT), for example, current harmonics spectrum and input impedance. Therefore, an online calculation tool is provided to help non-electrical experts. Following our procedures, unrealistic uncertainty estimations, unnecessary procedures and expensive equipment can be prevented.
Development of Inspection for Friction Stir Welds for Rocket Fuel Tanks
NASA Technical Reports Server (NTRS)
Russell, Samuel S.
2012-01-01
During development of the Ares I weld processes nondestructive and destructive testing were used to identify and characterize defects that occurred. These defects were named and character noted. This catalogue of defects and characteristics was then used to develop inspection methods for Self Reacting Friction Stir Welds (SR ]FSW) and Conventional Friction Stir Welds (C ]FSW). Dye penetrant, eddy current, x ]radiography, single element ultrasonic, and phased array ultrasonic (PAUT) inspection procedures were developed to target the expected defects. Once the method procedure was developed a comparison was performed to allow for selection of the best inspection method. Tests of the effectiveness of the inspection were performed on purposely fabricated flawed specimens and electrodischarge machined notches. The initial test results prompted a revisit of the PAUT procedure and a redesign of the inspection. Subsequent testing showed that a multi ]angle PAUT inspection resulted in better detection capability. A discussion of the most effective orientations of the PAUT transducer will be presented. Also, the implementation of the inspection on production hardware will be presented. In some cases the weld tool is used as the transducer manipulator and in some cases a portable scanner is used
Radiologic evaluation of acute chest pain--suspected myocardial ischemia.
Stanford, William
2007-08-15
The American College of Radiology has developed appropriateness criteria for a number of clinical conditions and procedures. Criteria are available on imaging tests used in the evaluation of acute chest pain--suspected myocardial ischemia. Imaging tests for a suspected cardiac etiology include transthoracic echocardiography, transesophageal echocardiography, radionuclide perfusion imaging, radionuclide ventriculography, radionuclide infarct avid imaging, and positron emission tomography. If the cardiac ischemic work-up is negative or indeterminate, applicable tests include chest radiography; conventional, multidetector, and electron beam computed tomography; and magnetic resonance imaging. A summary of the criteria, with the advantages and limitations of each test, is presented in this article.
NASA Astrophysics Data System (ADS)
Zenkov, E. V.
2018-01-01
Two methods are given in the article by considering the type of stressed-Deformed state (SDS) based on equations limit condition and analyzing the results of laboratory tests of special specimens for mechanical testing, focus having destruction thereof in the same view of SDS as in focus possible destruction of the structural member. The considered limited use of these methods in terms of considering physically consistent strength criterion type Pisarenko-Lebedev. A revised design-experimental procedure for determining the strength of the material of the structure, combining therein the elements of these two methods, consisting in determining the strength parameters of construction material, entering criterion equation Pisarenko-Lebedev, considering the actual appearance of the region-of-interest SDS structure. The implementation of the procedure is performed on the basis of the selection of the respective experimental laboratory specimens for mechanical testing, plan SDS in working zone coinciding with a SDS: structure whose strength is evaluated. The refinement process limit state equations demonstrated in determining 50CrV4 steel strength parameters, being in a state of biaxial stretching. Design-experimentally determined by, that steel for a given voltage limit value is almost a quarter of its value is reduced compared to the conventional tensile strength. value is reduced compared to the conventional tensile strength.
Köhnke, Robert; Kolk, Andreas; Kluwe, Lan; Ploder, Oliver
2017-09-01
To evaluate piezosurgery for bilateral sagittal split osteotomy (BSSO) for its duration and inferior alveolar nerve (IAN) perturbation. In this prospective randomized study, the authors evaluated 100 BSSO procedures in 50 patients. Piezoelectric (group I) and conventional (group II) osteotomies were carried out on each side of the mandible of a patient by 2 specialists. The surgeons had at least 1 year of experience using piezosurgery. The period from incision to complete splitting of the mandibular bone was recorded (ie, procedure duration). The intraoperative status (visibility and relocation) of the IAN also was recorded. The neurosensory function of the IAN was measured by the 2-point discrimination threshold and static light touch methods before surgery and postoperatively (1, 3, and 6 weeks and 6 and 12 months). Parameters were compared between the test groups by the paired t, nonparametric Wilcoxon, or χ 2 test. Intergroup comparison showed the mean duration of osteotomy was significantly shorter for group I (17 ± 6 vs 25 ± 9 minutes; P < .001). The rate of intraoperative exposures of the IAN was slightly lower for group I (68%) compared with group II (81%). However, the difference was not relevant. Neurosensory disturbance and recovery of the IAN did not differ between groups. Piezoelectric osteotomy requires considerably less time than conventional mechanical approaches, but shows no advantage in preventing neurosensory perturbation. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Diagnostic Assessment of Troubleshooting Skill in an Intelligent Tutoring System
1994-03-01
the information that can be provided from studying gauges and indicators and conventional test equipment procedures. Experts are particularly adept at...uses the results of the strategy and action evaluator to update the student profile, represented as a network, using the ERGO ( Noetic Systems, 1993...1990). Individualized tutoring using an intelligent fuzzy temporal relational database. International Tournal of Man-Machine Studies . & 409-429. . 34
The Comprehension of Familiar and Novel Metaphoric Meanings in Schizophrenia: A Pilot Study.
Rapp, Alexander M; Felsenheimer, Anne K; Langohr, Karin; Klupp, Magdalena
2017-01-01
Miscomprehension of nonliteral ("figurative") language like metaphors, proverbs, idioms, and ironic expressions by patients with schizophrenia is a phenomenon mentioned already in historical psychiatric descriptions. However, it was only recently that studies did differentiate between novel and conventional metaphors, a factor that is known to influence the difficulty of comprehension in healthy subjects. Further, familiarity with stimuli is an important factor for comprehension, which was not recommended in utmost previous studies. In this study, 23 patients with DSM IV schizophrenia and 19 healthy control subjects performed a newly-developed German metaphor comprehension test with three types of stimuli: novel metaphors, conventional German metaphors, and meaningless statements. During the test procedure, participants indicated familiarity with the stimulus and then matched the meaning with one out of four given alternatives. Familiarity rankings did not significantly differ between patients and control subjects. However, on descriptive level, there was a tendency for healthy controls to be more familiar with conventional metaphors than schizophrenic patients. Further, comprehension of conventional and novel metaphors differed significantly between the groups, with higher performance in healthy controls. Considering only those metaphors that had been ranked as familiar, patients only revealed significant lower performance opposed to controls regarding novel metaphors, while they did not differ in conventional metaphors. Taken together, the results indicate that patients with schizophrenia might show an altered way of comprehension in novel metaphors, leading to more misunderstandings. However, their previously reported impairments in conventional metaphors might rather be due to a lack of familiarity with the stimuli-making conventional metaphors to novel metaphors in the individual case.
The Comprehension of Familiar and Novel Metaphoric Meanings in Schizophrenia: A Pilot Study
Rapp, Alexander M.; Felsenheimer, Anne K.; Langohr, Karin; Klupp, Magdalena
2018-01-01
Miscomprehension of nonliteral (“figurative”) language like metaphors, proverbs, idioms, and ironic expressions by patients with schizophrenia is a phenomenon mentioned already in historical psychiatric descriptions. However, it was only recently that studies did differentiate between novel and conventional metaphors, a factor that is known to influence the difficulty of comprehension in healthy subjects. Further, familiarity with stimuli is an important factor for comprehension, which was not recommended in utmost previous studies. In this study, 23 patients with DSM IV schizophrenia and 19 healthy control subjects performed a newly-developed German metaphor comprehension test with three types of stimuli: novel metaphors, conventional German metaphors, and meaningless statements. During the test procedure, participants indicated familiarity with the stimulus and then matched the meaning with one out of four given alternatives. Familiarity rankings did not significantly differ between patients and control subjects. However, on descriptive level, there was a tendency for healthy controls to be more familiar with conventional metaphors than schizophrenic patients. Further, comprehension of conventional and novel metaphors differed significantly between the groups, with higher performance in healthy controls. Considering only those metaphors that had been ranked as familiar, patients only revealed significant lower performance opposed to controls regarding novel metaphors, while they did not differ in conventional metaphors. Taken together, the results indicate that patients with schizophrenia might show an altered way of comprehension in novel metaphors, leading to more misunderstandings. However, their previously reported impairments in conventional metaphors might rather be due to a lack of familiarity with the stimuli—making conventional metaphors to novel metaphors in the individual case. PMID:29354082
Designing the microturbine engine for waste-derived fuels.
Seljak, Tine; Katrašnik, Tomaž
2016-01-01
Presented paper deals with adaptation procedure of a microturbine (MGT) for exploitation of refuse derived fuels (RDF). RDF often possess significantly different properties than conventional fuels and usually require at least some adaptations of internal combustion systems to obtain full functionality. With the methodology, developed in the paper it is possible to evaluate the extent of required adaptations by performing a thorough analysis of fuel combustion properties in a dedicated experimental rig suitable for testing of wide-variety of waste and biomass derived fuels. In the first part key turbine components are analyzed followed by cause and effect analysis of interaction between different fuel properties and design parameters of the components. The data are then used to build a dedicated test system where two fuels with diametric physical and chemical properties are tested - liquefied biomass waste (LW) and waste tire pyrolysis oil (TPO). The analysis suggests that exploitation of LW requires higher complexity of target MGT system as stable combustion can be achieved only with regenerative thermodynamic cycle, high fuel preheat temperatures and optimized fuel injection nozzle. Contrary, TPO requires less complex MGT design and sufficient operational stability is achieved already with simple cycle MGT and conventional fuel system. The presented approach of testing can significantly reduce the extent and cost of required adaptations of commercial system as pre-selection procedure of suitable MGT is done in developed test system. The obtained data can at the same time serve as an input for fine-tuning the processes for RDF production. Copyright © 2015. Published by Elsevier Ltd.
Extraction of kiwi seed oil: Soxhlet versus four different non-conventional techniques.
Cravotto, Giancarlo; Bicchi, Carlo; Mantegna, Stefano; Binello, Arianna; Tomao, Valerie; Chemat, Farid
2011-06-01
Kiwi seed oil has a nutritionally interesting fatty acid profile, but a rather low oxidative stability, which requires careful extraction procedures and adequate packaging and storage. For these reasons and with the aim to achieve process intensification with shorter extraction time, lower energy consumption and higher yields, four different non-conventional techniques were experimented. Kiwi seeds were extracted in hexane using classic Soxhlet as well as under power ultrasound (US), microwaves (MWs; closed vessel) and MW-integrated Soxhlet. Supercritical CO₂ was also employed and compared to the other techniques in term of yield, extraction time, fatty acid profiles and organoleptic properties. All these non-conventional techniques are fast, effective and safe. A sensory evaluation test showed the presence of off-flavours in oil samples extracted by Soxhlet and US, an indicator of partial degradation.
Martin, F N; Coffey, M D; Zeller, K; Hamelin, R C; Tooley, P; Garbelotto, M; Hughes, K J D; Kubisiak, T; Bilodeau, G J; Levy, L; Blomquist, C; Berger, P H
2009-04-01
Given the importance of Phytophthora ramorum from a regulatory standpoint, it is imperative that molecular markers for pathogen detection are fully tested to evaluate their specificity in detection of the pathogen. In an effort to evaluate 11 reported diagnostic techniques, we assembled a standardized DNA library using accessions from the World Phytophthora Genetic Resource Collection for 315 isolates representing 60 described Phytophthora spp. as well as 11 taxonomically unclassified isolates. These were sent blind to collaborators in seven laboratories to evaluate published diagnostic procedures using conventional (based on internal transcribed spacer [ITS] and cytochrome oxidase gene [cox]1 and 2 spacer regions) and real-time polymerase chain reaction (based on ITS and cox1 and 2 spacer regions as well as beta-tubulin and elicitin genes). Single-strand conformation polymorphism (SSCP) analysis using an automated sequencer for data collection was also evaluated for identification of all species tested. In general, the procedures worked well, with varying levels of specificity observed among the different techniques. With few exceptions, all assays correctly identified all isolates of P. ramorum and low levels of false positives were observed for the mitochondrial cox spacer markers and most of the real-time assays based on nuclear markers (diagnostic specificity between 96.9 and 100%). The highest level of false positives was obtained with the conventional nested ITS procedure; however, this technique is not stand-alone and is used in conjunction with two other assays for diagnostic purposes. The results indicated that using multiple assays improved the accuracy of the results compared with looking at a single assay alone, in particular when the markers represented different genetic loci. The SSCP procedure accurately identified P. ramorum and was helpful in classification of a number of isolates to a species level. With one exception, all procedures accurately identified P. ramorum in blind evaluations of 60 field samples that included examples of plant infection by 11 other Phytophthora spp. The SSCP analysis identified eight of these species, with three identified to a species group.
Global Harmonization of Quality Assurance Naming Conventions in Radiation Therapy Clinical Trials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Melidis, Christos, E-mail: christos.melidis@eortc.be; Bosch, Walther R.; Izewska, Joanna
2014-12-01
Purpose: To review the various radiation therapy quality assurance (RTQA) procedures used by the Global Clinical Trials RTQA Harmonization Group (GHG) steering committee members and present the harmonized RTQA naming conventions by amalgamating procedures with similar objectives. Methods and Materials: A survey of the GHG steering committee members' RTQA procedures, their goals, and naming conventions was conducted. The RTQA procedures were classified as baseline, preaccrual, and prospective/retrospective data capture and analysis. After all the procedures were accumulated and described, extensive discussions took place to come to harmonized RTQA procedures and names. Results: The RTQA procedures implemented within a trial by themore » GHG steering committee members vary in quantity, timing, name, and compliance criteria. The procedures of each member are based on perceived chances of noncompliance, so that the quality of radiation therapy planning and treatment does not negatively influence the trial measured outcomes. A comparison of these procedures demonstrated similarities among the goals of the various methods, but the naming given to each differed. After thorough discussions, the GHG steering committee members amalgamated the 27 RTQA procedures to 10 harmonized ones with corresponding names: facility questionnaire, beam output audit, benchmark case, dummy run, complex treatment dosimetry check, virtual phantom, individual case review, review of patients' treatment records, and protocol compliance and dosimetry site visit. Conclusions: Harmonized RTQA harmonized naming conventions, which can be used in all future clinical trials involving radiation therapy, have been established. Harmonized procedures will facilitate future intergroup trial collaboration and help to ensure comparable RTQA between international trials, which enables meta-analyses and reduces RTQA workload for intergroup studies.« less
Long memory and multifractality: A joint test
NASA Astrophysics Data System (ADS)
Goddard, John; Onali, Enrico
2016-06-01
The properties of statistical tests for hypotheses concerning the parameters of the multifractal model of asset returns (MMAR) are investigated, using Monte Carlo techniques. We show that, in the presence of multifractality, conventional tests of long memory tend to over-reject the null hypothesis of no long memory. Our test addresses this issue by jointly estimating long memory and multifractality. The estimation and test procedures are applied to exchange rate data for 12 currencies. Among the nested model specifications that are investigated, in 11 out of 12 cases, daily returns are most appropriately characterized by a variant of the MMAR that applies a multifractal time-deformation process to NIID returns. There is no evidence of long memory.
Pressure-Sensitive Paint Measurements on Surfaces with Non-Uniform Temperature
NASA Technical Reports Server (NTRS)
Bencic, Timothy J.
1999-01-01
Pressure-sensitive paint (PSP) has become a useful tool to augment conventional pressure taps in measuring the surface pressure distribution of aerodynamic components in wind tunnel testing. While the PSP offers the advantage of a non-intrusive global mapping of the surface pressure, one prominent drawback to the accuracy of this technique is the inherent temperature sensitivity of the coating's luminescent intensity. A typical aerodynamic surface PSP test has relied on the coated surface to be both spatially and temporally isothermal, along with conventional instrumentation for an in situ calibration to generate the highest accuracy pressure mappings. In some tests however, spatial and temporal thermal gradients are generated by the nature of the test as in a blowing jet impinging on a surface. In these cases, the temperature variations on the painted surface must be accounted for in order to yield high accuracy and reliable data. A new temperature correction technique was developed at NASA Lewis to collapse a "family" of PSP calibration curves to a single intensity ratio versus pressure curve. This correction allows a streamlined procedure to be followed whether or not temperature information is used in the data reduction of the PSP. This paper explores the use of conventional instrumentation such as thermocouples and pressure taps along with temperature-sensitive paint (TSP) to correct for the thermal gradients that exist in aeropropulsion PSP tests. Temperature corrected PSP measurements for both a supersonic mixer ejector and jet cavity interaction tests are presented.
NASA Technical Reports Server (NTRS)
Phillips, G. B.; Pace, V. A., Jr.
1972-01-01
The sampler utilizes permanent magnets and soft metal pole pieces to connect the cone/filter assembly to the sampling head and vacuum supply. The cone/filter assembly is packaged in a plastic container and presterilized so that the need for any human contact during the sampling procedure is completely eliminated. Microbiological tests have demonstrated that the sampling efficiency is not affected by the magnetic coupling apparatus and that the probe appears to function as efficiently as the conventional plastic and Sandia vacuum probes.
Production scheduling and rescheduling with genetic algorithms.
Bierwirth, C; Mattfeld, D C
1999-01-01
A general model for job shop scheduling is described which applies to static, dynamic and non-deterministic production environments. Next, a Genetic Algorithm is presented which solves the job shop scheduling problem. This algorithm is tested in a dynamic environment under different workload situations. Thereby, a highly efficient decoding procedure is proposed which strongly improves the quality of schedules. Finally, this technique is tested for scheduling and rescheduling in a non-deterministic environment. It is shown by experiment that conventional methods of production control are clearly outperformed at reasonable run-time costs.
Design and Testing of a Low Noise Flight Guidance Concept
NASA Technical Reports Server (NTRS)
Williams, David H.; Oseguera-Lohr, Rosa M.; Lewis, Elliot T.
2004-01-01
A flight guidance concept was developed to assist in flying continuous descent approach (CDA) procedures designed to lower the noise under the flight path of jet transport aircraft during arrival operations at an airport. The guidance consists of a trajectory prediction algorithm that was tuned to produce a high-efficiency, low noise flight profile with accompanying autopilot and flight display elements needed by the flight control system and pilot to fly the approach. A key component of the flight guidance was a real-time display of energy error relative to the predicted flight path. The guidance was integrated with the conventional Flight Management System (FMS) guidance of a modern jet transport airplane and tested in a high fidelity flight simulation. A charted arrival procedure, which allowed flying conventional arrivals, CDA arrivals with standard guidance, and CDA arrivals with the new low noise guidance, was developed to assist in the testing and evaluation of the low noise guidance concept. Results of the simulation testing showed the low noise guidance was easy to use by airline pilot test subjects and effective in achieving the desired noise reduction. Noise under the flight path was reduced by at least 2 decibels in Sound Exposure Level (SEL) at distances from about 3 nautical miles out to about 17.5 nautical miles from the runway, with a peak reduction of 8.5 decibels at about 10.5 nautical miles. Fuel consumption was also reduced by about 17% for the LNG conditions compared to baseline runs for the same flight distance. Pilot acceptance and understanding of the guidance was quite high with favorable comments and ratings received from all test subjects.
Dijkman, A B; Mol, B W; van der Veen, F; Bossuyt, P M; Hogerzeil, H V
2000-07-01
Hysterosalpingo-contrastsonography (HyCoSy) is a new method for assessing tubal patency using transvaginal ultrasound. It is thought to have several advantages over conventional hysterosalpingography (HSG). We prospectively evaluated the performance of HyCoSy and HSG in the diagnosis of tubal pathology. One-hundred consecutive subfertile women underwent both HyCoSy and HSG in randomised order. Results of both tests were related to findings at laparoscopy with dye, which was used as the reference test. Each woman was asked to score the pain exsperienced at both procedures on a visual analogue scale. When laparoscopy with dye was used as reference test, the likelihood ratios of HyCoSy were slightly inferior to those obtained for HSG. Since the performance of HyCoSy was dependent on experience, the results were recalculated omitting the 50 initial procedures from the analysis. In that calculation, results of HyCoSy and HSG were comparable. There were no differences in pain experienced during the procedure, as there appeared also to be no differences in patient preferences. There appear to be no strong arguments either to replace HSG by HyCoSy, or to reject the use of HyCoSy. Both procedures can be used in the evaluation of tubal pathology.
Development of a needle driver with multiple degrees of freedom for neonatal laparoscopic surgery.
Ishimaru, Tetsuya; Takazawa, Shinya; Uchida, Hiroo; Kawashima, Hiroshi; Fujii, Masahiro; Harada, Kanako; Sugita, Naohiko; Mitsuishi, Mamoru; Iwanaka, Tadashi
2013-07-01
The aims of this study were to develop a thin needle driver with multiple degrees of freedom and to evaluate its efficacy in multidirectional suturing compared with a conventional needle driver. The tip (15 mm) of the novel user-friendly needle driver (3.5 mm in diameter) has three degrees of freedom for grasping, rotation, and deflection. Six pediatric surgeons performed two kinds of suturing tasks in a dry box: three stitches in continuous suturing that were perpendicular or parallel to the insertion direction of the instrument, first using the novel instrument, then using a conventional instrument, and finally using the novel instrument again. The accuracy of insertion and exit compared with the target points and the procedure time were measured. In the conventional and novel procedures the mean gaps from the insertion point to the target in perpendicular suturing were 0.8 mm and 0.7 mm, respectively; in parallel suturing they were 0.8 mm and 0.6 mm, respectively. The mean gaps from the exit point to the target in perpendicular suturing were 0.6 mm and 0.6 mm for conventional and novel procedures, respectively; in parallel suturing they were 0.6 mm and 0.8 mm, respectively. The procedure time for perpendicular suturing was 33 seconds and 64 seconds for conventional and novel procedures, respectively (P=.02); for parallel suturing it was 114 seconds and 91 seconds, respectively. Our novel needle driver maintained accuracy of suturing; parallel suturing with the novel driver may be easier than with the conventional one.
NASA Technical Reports Server (NTRS)
Stein, M.; Housner, J. D.
1978-01-01
A numerical analysis developed for the buckling of rectangular orthotropic layered panels under combined shear and compression is described. This analysis uses a central finite difference procedure based on trigonometric functions instead of using the conventional finite differences which are based on polynomial functions. Inasmuch as the buckle mode shape is usually trigonometric in nature, the analysis using trigonometric finite differences can be made to exhibit a much faster convergence rate than that using conventional differences. Also, the trigonometric finite difference procedure leads to difference equations having the same form as conventional finite differences; thereby allowing available conventional finite difference formulations to be converted readily to trigonometric form. For two-dimensional problems, the procedure introduces two numerical parameters into the analysis. Engineering approaches for the selection of these parameters are presented and the analysis procedure is demonstrated by application to several isotropic and orthotropic panel buckling problems. Among these problems is the shear buckling of stiffened isotropic and filamentary composite panels in which the stiffener is broken. Results indicate that a break may degrade the effect of the stiffener to the extent that the panel will not carry much more load than if the stiffener were absent.
Engineering analysis of shortfall for new technologies. Analysis memorandum
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1981-03-11
The engineering principles that govern the mpg performance of alternative technologies on the EPA test procedure and under in-use conditions are examined. The results can be used to interpret the shortfall of alternative technologies derived from statistical analyses. The analysis examines each of the four technologies in comparison to the conventional technology counterpart. Manual transmissions are compared to automatics, fuel injected S.I. engines to carburetted S.I. engines, front-wheel drive vehicles to rear-wheel drive vehicles and diesel engines to carburetted S.I. engines. The changes in shortfall of the four technologies in comparison to conventional technologies are explained through differences in responsesmore » to the factors.« less
Code of Federal Regulations, 2011 CFR
2011-01-01
... COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS CWC CLARIFICATION PROCEDURES (CONSULTATIONS AND CHALLENGE... through consultation between themselves or through the Organization for the Prohibition of Chemical Weapons (OPCW). A State Party may also request the OPCW to conduct an on-site challenge inspection of any...
Report on the study of the tax and rate treatment of renewable energy projects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hadley, S.W.; Hill, L.J.; Perlack, R.D.
1993-12-01
This study was conducted in response to the requirements of Section 1205 of the Energy Policy Act of 1992 (EPACT), which states: The Secretary (of Energy), in conjunction with State regulatory commissions, shall undertake a study to determine if conventional taxation and ratemaking procedures result in economic barriers to or incentives for renewable energy power plants compared to conventional power plants. The purpose of the study, therefore, is not to compare the cost-effectiveness of different types of renewable and conventional electric generating plants. Rather, it is to determine the relative impact of conventional ratemaking and taxation procedures on the selectionmore » of renewable power plants compared to conventional ones. To make this determination, we quantify the technical and financial parameters of renewable and conventional electric generating technologies, and hold them fixed throughout the study. Then, we vary taxation and ratemaking procedures to determine their effects on the financial criteria that investor-owned electric utilities (IOUs) and nonutility electricity generators (NUGs) use to make technology-adoption decisions. In the planning process of a typical utility, the opposite is usually the case. That is, utilities typically hold ratemaking and taxation procedures constant and look for the least-cost mix of resources, varying the values of engineering and financial parameters of generating plants in the process.« less
Determination of Material Strengths by Hydraulic Bulge Test.
Wang, Hankui; Xu, Tong; Shou, Binan
2016-12-30
The hydraulic bulge test (HBT) method is proposed to determine material tensile strengths. The basic idea of HBT is similar to the small punch test (SPT), but inspired by the manufacturing process of rupture discs-high-pressure hydraulic oil is used instead of punch to cause specimen deformation. Compared with SPT method, the HBT method can avoid some of influence factors, such as punch dimension, punch material, and the friction between punch and specimen. A calculation procedure that is entirely based on theoretical derivation is proposed for estimate yield strength and ultimate tensile strength. Both conventional tensile tests and hydraulic bulge tests were carried out for several ferrous alloys, and the results showed that hydraulic bulge test results are reliable and accurate.
Defense Small Business Innovation Research Program (SBIR) FY 1984.
1984-01-12
nuclear submarine non-metallic, light weight, high strength piping . Includes the development of adequate fabrication procedures for attaching pipe ...waste heat economizer methods, require development. Improved conventional and hybrid heat pipes and/or two phase transport devices 149 IF are required...DESCRIPTION: A need exists to conceive, design, fabricate and test a method of adjusting the length of the individual legs of nylon or Kevlar rope sling
Giro, Gabriela; Tovar, Nick; Marin, Charles; Bonfante, Estevam A.; Jimbo, Ryo; Suzuki, Marcelo; Janal, Malvin N.; Coelho, Paulo G.
2013-01-01
Objectives. To test the hypothesis that there would be no differences in osseointegration by reducing the number of drills for site preparation relative to conventional drilling sequence. Methods. Seventy-two implants were bilaterally placed in the tibia of 18 beagle dogs and remained for 1, 3, and 5 weeks. Thirty-six implants were 3.75 mm in diameter and the other 36 were 4.2 mm. Half of the implants of each diameter were placed under a simplified technique (pilot drill + final diameter drill) and the other half were placed under conventional drilling where multiple drills of increasing diameter were utilized. After euthanisation, the bone-implant samples were processed and referred to histological analysis. Bone-to-implant contact (BIC) and bone-area-fraction occupancy (BAFO) were assessed. Statistical analyses were performed by GLM ANOVA at 95% level of significance considering implant diameter, time in vivo, and drilling procedure as independent variables and BIC and BAFO as the dependent variables. Results. Both techniques led to implant integration. No differences in BIC and BAFO were observed between drilling procedures as time elapsed in vivo. Conclusions. The simplified drilling protocol presented comparable osseointegration outcomes to the conventional protocol, which proved the initial hypothesis. PMID:23431303
The rapid measurement of soil carbon stock using near-infrared technology
NASA Astrophysics Data System (ADS)
Kusumo, B. H.; Sukartono; Bustan
2018-03-01
As a soil pool stores carbon (C) three times higher than an atmospheric pool, the depletion of C stock in the soil will significantly increase the concentration of CO2 in the atmosphere, causing global warming. However, the monitoring or measurement of soil C stock using conventional procedures is time-consuming and expensive. So it requires a rapid and non-destructive technique that is simple and does not need chemical substances. This research is aimed at testing whether near-infrared (NIR) technology is able to rapidly measure C stock in the soil. Soil samples were collected from an agricultural land at the sub-district of Kayangan, North Lombok, Indonesia. The coordinates of the samples were recorded. Parts of the samples were analyzed using conventional procedure (Walkley and Black) and some other parts were scanned using near-infrared spectroscopy (NIRS) for soil spectral collection. Partial Least Square Regression (PLSR) was used to develop models from soil C data measured by conventional analysis and from spectral data scanned by NIRS. The best model was moderately successful to measure soil C stock in the study area in North Lombok. This indicates that the NIR technology can be further used to monitor the change of soil C stock in the soil.
Evaluation of deflection forces of orthodontic wires with different ligation types.
Henriques, José Fernando Castanha; Higa, Rodrigo Hitoshi; Semenara, Nayara Thiago; Janson, Guilherme; Fernandes, Thais Maria Freire; Sathler, Renata
2017-07-03
The aim of this study was to evaluate deflection forces of orthodontic wires of different alloys engaged into conventional brackets using several ligation types. Stainless steel, conventional superelastic nickel-titanium and thermally activated nickel-titanium archwires tied into conventional brackets by a ring-shaped elastomeric ligature (RSEL), a 8-shaped elastomeric ligature (8SEL) and a metal ligature (ML) were tested. A clinical simulation device was created especially for this study and forces were measured with an Instron Universal Testing Machine. For the testing procedure, the block representing the maxillary right central incisor was moved 0.5 and 1 mm bucco-lingually at a constant speed of 2 mm/min, and the forces released by the wires were recorded, in accordance with the ISO 15841 guidelines. In general, the RSEL showed lighter forces, while 8SEL and ML showed higher values. At the 0.5 mm deflection, the 8SEL presented the greatest force, but at the 1.0 mm deflection the ML had a statistically similar force. Based on our evaluations, to obtain lighter forces, the thermally activated nickel-titanium wire with the RSEL are recommended, while the steel wire with the 8SEL or the ML are recommended when larger forces are desired. The ML exhibited the highest force increase with increased deflections, compared with the elastomeric ligatures.
Fractography used with lifetime prediction tests on commercial grades of alumina and silicon carbide
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuebler, J.; Woodtli, J.; Berroth, K.
1996-12-31
Fractographic investigations were conducted on alumina and {alpha}-SSiC bend bars from a round robin test comparing a static and a dynamic lifetime test method. The investigations revealed that not all fracture origins found on {alpha}-SSiC specimens had contact with the ambient medium and therefore the dynamic lifetime tests did not measure the materials` behaviour under stress in water. In addition to the conventional SEM fractography an alternate technique, using an auto focus scanning laser profilometer was applied for characterizing the fractures. This tool is very promising for fractography because of the ability to handle topographic data by imaging procedures andmore » fractal analysis.« less
Development of a Free-to-Roll Transonic Test Capability (Invited)
NASA Technical Reports Server (NTRS)
Capone, F. J.; Owens, D. B.; Hall, R. M.
2003-01-01
As part of the NASA/Navy Abrupt Wing Stall Program, a relatively low-cost, rapid-access wind-tunnel free-to-roll rig was developed. This rig combines the use of conventional models and test apparatuses to evaluate both transonic performance and wing-drop/rock tendencies in a single tunnel entry. A description of the test hardware as well as a description of the experimental procedures is given. The free-to-roll test rig has been used successfully to assess the static and dynamic characteristics of three different configurations--two configurations that exhibit uncommanded lateral motions, (pre-production F/A-18E and AV-8B), and one that did not (F/A-18C).
Manufacturing implant supported auricular prostheses by rapid prototyping techniques.
Karatas, Meltem Ozdemir; Cifter, Ebru Demet; Ozenen, Didem Ozdemir; Balik, Ali; Tuncer, Erman Bulent
2011-08-01
Maxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to. Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid prototyping techniques have been developed for extraoral prosthesis in order to reduce these disadvantages of conventional methods. Rapid prototyping technique has the potential to simplify the procedure and decrease the laboratory work required. It eliminates the need for measurement impression procedures and preparation of wax model to be performed by prosthodontists themselves In the near future this technology will become a standard for fabricating maxillofacial prostheses.
Assessment of Conventional Teaching Procedures: Implications for Gifted Learners
ERIC Educational Resources Information Center
Alenizi, Mogbel Aid K.
2016-01-01
The present research aims to assess the conventional teaching procedures in the development of mathematical skills of the students with learning difficulties. The study group was made up of all the children with academic learning disorders in KSA. The research questions have been scrutinized from the averages and the standard deviation of the…
Lima, G P P; Teixeira da Silva, Jaime A; Bernhard, A B; Pirozzi, D C Z; Fleuri, L F; Vianello, F
2012-01-01
Different parts of plant foods are generally discarded by consumers such as peel, stalk and leaves, which could however possess a nutritional value. However, few studies have analysed the composition of these marginal foods. The phenolic compound, flavonoid, polyamine, nitrate and pesticide contents of parts of vegetables that are usually discarded--but which were cultivated according to conventional and non-conventional procedures--were analysed to provide suggestions on how to improve the consumption of these parts and to reduce the production of urban solid waste. Few, but significant, differences between the two manuring procedures were observed. Higher nitrate content and the presence of organochlorine pesticides were found in conventional cultivated papaya peel, lemon balm leaves, jack fruit pulp, and beet stalk and peel. Discarded parts of plant foods such as stalk, leaves and peels can be used as a source of antioxidant compounds, such as phenolic compounds.
Alex, Deepa; Shetty, Y. Bharath; Miranda, Glynis Anita; Prabhu, M. Bharath; Karkera, Reshma
2015-01-01
Background: Conventional investing and casting techniques are time-consuming and usually requires 2–4 h for completion. Accelerated nonstandard, casting techniques have been reported to achieve similar quality results in significantly less time, namely, in 30–40 min. During casting, it is essential to achieve compensation for the shrinkage of solidifying alloy by investment expansion. The metal casting ring restricts the thermal expansion of investment because the thermal expansion of the ring is lesser than that of the investment. The use of casting ring was challenged with the introduction of the ringless technique. Materials and Methods: A total of 40 test samples of nickel chromium (Ni-Cr) cast copings were obtained from the patterns fabricated using inlay casting wax. The 20 wax patterns were invested using metal ring and 20 wax patterns were invested using the ringless investment system. Of both the groups, 10 samples underwent conventional casting, and the other 10 underwent accelerated casting. The patterns were casted using the induction casting technique. All the test samples of cast copings were evaluated for vertical marginal gaps at four points on the die employing a stereo optical microscope. Results: The vertical marginal discrepancy data obtained were tabulated. Mean and standard deviations were obtained. Vertical discrepancies were analyzed using analysis of variance and Tukey honestly significantly different. The data obtained were found to be very highly significant (P < 0.001). Mean vertical gap was the maximum for Group II (53.64 μm) followed by Group IV (47.62 μm), Group I (44.83 μm) and Group III (35.35 μm). Conclusion: The Ni-Cr cast copings fabricated with the conventional casting using ringless investment system showed significantly better marginal fit than that of cast copings fabricated from conventional and accelerated casting with metal ring investment and accelerated casting using ringless investment since those copings had shown the least vertical marginal discrepancies among the four methods evaluated in this study. PMID:26929488
A new method for assessing the accuracy of full arch impressions in patients.
Kuhr, F; Schmidt, A; Rehmann, P; Wöstmann, B
2016-12-01
To evaluate a new method of measuring the real deviation (trueness) of full arch impressions intraorally and to investigate the trueness of digital full arch impressions in comparison to a conventional impression procedure in clinical use. Four metal spheres were fixed with composite using a metal application aid to the lower teeth of 50 test subjects as reference structures. One conventional impression (Impregum Penta Soft) with subsequent type-IV gypsum model casting (CI) and three different digital impressions were performed in the lower jaw of each test person with the following intraoral scanners: Sirona CEREC Omnicam (OC), 3M True Definition (TD), Heraeus Cara TRIOS (cT). The digital and conventional (gypsum) models were analyzed relative to the spheres. Linear distance and angle measurements between the spheres, as well as digital superimpositions of the spheres with the reference data set were executed. With regard to the distance measurements, CI showed the smallest deviations followed by intraoral scanners TD, cT and OC. A digital superimposition procedure yielded the same order for the outcomes: CI (15±4μm), TD (23±9μm), cT (37±14μm), OC (214±38μm). Angle measurements revealed the smallest deviation for TD (0.06°±0,07°) followed by CI (0.07°±0.07°), cT (0.13°±0.15°) and OC (0.28°±0.21°). The new measuring method is suitable for measuring the dimensional accuracy of full arch impressions intraorally. CI is still significantly more accurate than full arch scans with intraoral scanners in clinical use. Conventional full arch impressions with polyether impression materials are still more accurate than full arch digital impressions. Digital impression systems using powder application and active wavefront sampling technology achieve the most accurate results in comparison to other intraoral scanning systems (DRKS-ID: DRKS00009360, German Clinical Trials Register). Copyright © 2016 Elsevier Ltd. All rights reserved.
Reliability analysis applied to structural tests
NASA Technical Reports Server (NTRS)
Diamond, P.; Payne, A. O.
1972-01-01
The application of reliability theory to predict, from structural fatigue test data, the risk of failure of a structure under service conditions because its load-carrying capability is progressively reduced by the extension of a fatigue crack, is considered. The procedure is applicable to both safe-life and fail-safe structures and, for a prescribed safety level, it will enable an inspection procedure to be planned or, if inspection is not feasible, it will evaluate the life to replacement. The theory has been further developed to cope with the case of structures with initial cracks, such as can occur in modern high-strength materials which are susceptible to the formation of small flaws during the production process. The method has been applied to a structure of high-strength steel and the results are compared with those obtained by the current life estimation procedures. This has shown that the conventional methods can be unconservative in certain cases, depending on the characteristics of the structure and the design operating conditions. The suitability of the probabilistic approach to the interpretation of the results from full-scale fatigue testing of aircraft structures is discussed and the assumptions involved are examined.
Predictors of early stent occlusion among plastic biliary stents.
Khashab, Mouen A; Kim, Katherine; Hutfless, Susan; Lennon, Anne Marie; Kalloo, Anthony N; Singh, Vikesh K
2012-09-01
A major disadvantage of plastic biliary stents is their short patency rates. The aim of this study was to identify predictors of early stent occlusion among patients receiving conventional plastic biliary stents. Early stent occlusion was defined as worsening cholestatic liver test results of a severity sufficiently significant to warrant ERCP with stent exchange prior to the planned stent exchange, or as symptoms of cholangitis. The association of cumulative stent diameter, demographics, stricture location, procedure indication, Charlson comorbidity index, history of prior early stent occlusion, presence of gallbladder, and performance of sphincteromy with the occurrence of early stent occlusion was studied using logistic regression and multivariate analysis. Our patient cohort comprised 343 patients (mean age 59.3 years) who underwent 561 ERCP procedures with the placement of one or more plastic biliary stents (mean number of stents per procedure 1.2, mean total diameter of stents per procedure 12 Fr). Early stent occlusion occurred in 73 (13 %) procedures. Female gender was protective against early stent occlusion (adjusted OR 0.54, 95 % CI 0.32-0.90, p = 0.02), while hilar stricture location was independently associated with a significantly increased risk of early stent occlusion (adjusted OR 3.41, 95 % CI 1.68-6.90, p = 0.0007). Early occlusion of conventional biliary stents occurred in 13 % of cases. While female gender decreased the risk of early stent occlusion, hilar stricture location was a significant predictor of early stent occlusion. Our results suggest that physicians should consider early elective stent exchange in patients with hilar strictures.
Activity-based costing in radiology. Application in a pediatric radiological unit.
Laurila, J; Suramo, I; Brommels, M; Tolppanen, E M; Koivukangas, P; Lanning, P; Standertskjöld-Nordenstam, G
2000-03-01
To get an informative and detailed picture of the resource utilization in a radiology department in order to support its pricing and management. A system based mainly on the theoretical foundations of activity-based costing (ABC) was designed, tested and compared with conventional costing. The study was performed at the Pediatric Unit of the Department of Radiology, Oulu University Hospital. The material consisted of all the 7,452 radiological procedures done in the unit during the first half of 1994, when both methods of costing where in use. Detailed cost data were obtained from the hospital financial and personnel systems and then related to activity data captured in the radiology information system. The allocation of overhead costs was greatly reduced by the introduction of ABC compared to conventional costing. The overhead cost as a percentage of total costs dropped to one-fourth of total costs, from 57% to 16%. The change of unit costs of radiological procedures varied from -42% to +82%. Costing is much more detailed and precise, and the percentage of unspecified allocated overhead costs diminishes drastically when ABC is used. The new information enhances effective departmental management, as the whole process of radiological procedures is identifiable by single activities, amenable to corrective actions and process improvement.
B-737 flight test of curved-path and steep-angle approaches using MLS guidance
NASA Technical Reports Server (NTRS)
Branstetter, J. R.; White, W. F.
1989-01-01
A series of flight tests were conducted to collect data for jet transport aircraft flying curved-path and steep-angle approaches using Microwave Landing System (MLS) guidance. During the test, 432 approaches comprising seven different curved-paths and four glidepath angles varying from 3 to 4 degrees were flown in NASA Langley's Boeing 737 aircraft (Transport Systems Research Vehicle) using an MLS ground station at the NASA Wallops Flight Facility. Subject pilots from Piedmont Airlines flew the approaches using conventional cockpit instrumentation (flight director and Horizontal Situation Indicator (HSI). The data collected will be used by FAA procedures specialists to develop standards and criteria for designing MLS terminal approach procedures (TERPS). The use of flight simulation techniques greatly aided the preliminary stages of approach development work and saved a significant amount of costly flight time. This report is intended to complement a data report to be issued by the FAA Office of Aviation Standards which will contain all detailed data analysis and statistics.
A study of the high-frequency hearing thresholds of dentistry professionals
Lopes, Andréa Cintra; de Melo, Ana Dolores Passarelli; Santos, Cibele Carmelo
2012-01-01
Summary Introduction: In the dentistry practice, dentists are exposed to harmful effects caused by several factors, such as the noise produced by their work instruments. In 1959, the American Dental Association recommended periodical hearing assessments and the use of ear protectors. Aquiring more information regarding dentists', dental nurses', and prosthodontists' hearing abilities is necessary to propose prevention measures and early treatment strategies. Objective: To investigate the auditory thresholds of dentists, dental nurses, and prosthodontists. Method: In this clinical and experimental study, 44 dentists (Group I; GI), 36 dental nurses (Group II; GII), and 28 prosthodontists (Group III; GIII) were included, , with a total of 108 professionals. The procedures that were performed included a specific interview, ear canal inspection, conventional and high-frequency threshold audiometry, a speech reception threshold test, and an acoustic impedance test. Results: In the 3 groups that were tested, the comparison between the mean hearing thresholds provided evidence of worsened hearing ability relative to the increase in frequency. For the tritonal mean at 500 to 2,000 Hz and 3,000 to 6,000 Hz, GIII presented the worst thresholds. For the mean of the high frequencies (9,000 and 16,000 Hz), GII presented the worst thresholds. Conclusion: The conventional hearing threshold evaluation did not demonstrate alterations in the 3 groups that were tested; however, the complementary tests such as high-frequency audiometry provided greater efficacy in the early detection of hearing problems, since this population's hearing loss impaired hearing ability at frequencies that are not tested by the conventional tests. Therefore, we emphasize the need of utilizing high-frequency threshold audiometry in the hearing assessment routine in combination with other audiological tests. PMID:25991940
Manufacturing Implant Supported Auricular Prostheses by Rapid Prototyping Techniques
Karatas, Meltem Ozdemir; Cifter, Ebru Demet; Ozenen, Didem Ozdemir; Balik, Ali; Tuncer, Erman Bulent
2011-01-01
Maxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to. Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid prototyping techniques have been developed for extraoral prosthesis in order to reduce these disadvantages of conventional methods. Rapid prototyping technique has the potential to simplify the procedure and decrease the laboratory work required. It eliminates the need for measurement impression procedures and preparation of wax model to be performed by prosthodontists themselves In the near future this technology will become a standard for fabricating maxillofacial prostheses. PMID:21912504
Acoustic emission strand burning technique for motor burning rate prediction
NASA Technical Reports Server (NTRS)
Christensen, W. N.
1978-01-01
An acoustic emission (AE) method is being used to measure the burning rate of solid propellant strands. This method has a precision of 0.5% and excellent burning rate correlation with both subscale and large rocket motors. The AE procedure burns the sample under water and measures the burning rate from the acoustic output. The acoustic signal provides a continuous readout during testing, which allows complete data analysis rather than the start-stop clockwires used by the conventional method. The AE method helps eliminate such problems as inhibiting the sample, pressure increase and temperature rise, during testing.
Preparation of graphene thin films for radioactive samples.
Roteta, Miguel; Fernández-Martínez, Rodolfo; Mejuto, Marcos; Rucandio, Isabel
2016-03-01
A new method for the preparation of conductive thin films is presented. The metallization of VYNS films guarantees the electrical conductivity but it results in the breaking of a high proportion of them. Graphene, a two-dimensional nanostructure of monolayer or few layers graphite has attracted a great deal of attention because of its excellent properties such as a good chemical stability, mechanical resistance and extraordinary electronic transport properties. In this work, the possibilities of graphene have been explored as a way to produce electrical conductive thin films without an extra metallization process. The procedure starts with preparing homogenous suspensions of reduced graphene oxide (rGO) in conventional VYNS solutions. Ultra-sonication is used to ensure a good dispersibility of rGO. Graphene oxide (GO) is prepared via oxidation of graphite and subsequent exfoliation by sonication. Different chemically rGO were obtained by reaction with hydrazine sulfate, sodium borohydride, ascorbic acid and hydroiodic acid as reducing agents. The preparation of the thin graphene films is done in a similar way as the conventional VYNS foil preparation procedure. Drops of the solution are deposited onto water. The graphene films have been used to prepare sources containing some electron capture radionuclides ((109)Cd, (55)Fe, (139)Ce) with an activity in the order of 3kBq. The samples have been measured to test the attainable low energy electron efficiency and the energy resolution of Auger and conversion electrons by 4π (electron capture)-γ coincidence measurements. The 4π (electron capture)-γ coincidence setup includes a pressurized proportional counter and a NaI(Tl) detector. Tests with different pressures up to 1000kPa were carried out. All these tests show similar values in both parameters (efficiency and resolution) as those obtained by using the conventional metallized films without the drawback of the high percentage of broken films. Copyright © 2015 Elsevier Ltd. All rights reserved.
Matsushita, Taku; Sakuma, Miki; Tazawa, Shiori; Hatase, Taiki; Shirasaki, Nobutaka; Matsui, Yoshihiko
2017-11-15
Off-flavor in drinking water can be caused by transformation products (TPs) generated from organic compounds, such as amino acids, present during chlorination. However, the contributions of many of these TPs to overall off-flavor have not been quantified, mainly because the lack of appropriate chemical standards prevents sensory evaluation by means of a conventional flask test. In the present study, we used gas chromatography-mass spectrometry-olfactometry (GC-MS-O) to identify compounds responsible for the off-flavor generated by chlorination of an aqueous solution of the amino acid phenylalanine, and we propose a sensory evaluation procedure for quantification of the contributions of the identified TPs to the overall off-flavor, regardless of the availability of chemical standards of the TPs. GC-MS-O revealed that two TPs, N-chlorophenylacetaldimine and 2-chloro-2-phenylacetaldehyde, for which chemical standards are not commercially available, were the main components responsible for the off-flavor of the chlorinated solution. By using a sensory evaluation procedure involving a combination of GC-MS-O and a conventional flask test, we quantified the contributions of TPs to the overall off-flavor of the chlorinated solution. Approximately 60% of the off-flavor was attributable to free chlorine (13%), 2-chloro-2-phenylacetaldehyde (13%), trichloramine (12%) phenylacetaldehyde (11%) phenylacetonitrile (8%), and N-chlorophenylacetaldimine (2%). Treatment with powdered activated carbon (PAC) removed the off-flavor. Experiments with chlorination of 15 N-labeled phenylalanine suggested that PAC reductively decomposed trichloramine into N 2 gas and adsorbed all of the other identified TPs. Superfine PAC (median diameter, 0.7 μm) removed the off-flavor more rapidly than normal-size PAC (median diameter, 8.0 μm). Copyright © 2017 Elsevier Ltd. All rights reserved.
The detection and analysis of point processes in biological signals
NASA Technical Reports Server (NTRS)
Anderson, D. J.; Correia, M. J.
1977-01-01
A pragmatic approach to the detection and analysis of discrete events in biomedical signals is taken. Examples from both clinical and basic research are provided. Introductory sections discuss not only discrete events which are easily extracted from recordings by conventional threshold detectors but also events embedded in other information carrying signals. The primary considerations are factors governing event-time resolution and the effects limits to this resolution have on the subsequent analysis of the underlying process. The analysis portion describes tests for qualifying the records as stationary point processes and procedures for providing meaningful information about the biological signals under investigation. All of these procedures are designed to be implemented on laboratory computers of modest computational capacity.
Incorporating Data Link Messaging into a Multi-function Display for General Aviation Aircraft
NASA Technical Reports Server (NTRS)
Adams, Catherine A.; Murdoch, Jennifer L.
2006-01-01
One objective of the Small Aircraft Transportation System (SATS) Project is to increase the capacity and utilization of small non-towered, non-radar equipped airports by transferring traffic management activities to an automated system and separation responsibilities to general aviation (GA) pilots. This paper describes the development of a research multi-function display (MFD) to support the interaction between pilots and an automated Airport Management Module (AMM). Preliminary results of simulation and flight tests indicate that adding the responsibility of monitoring other traffic for self-separation does not increase pilots subjective workload levels. Pilots preferred using the enhanced MFD to execute flight procedures, reporting improved situation awareness over conventional instrument flight rules (IFR) procedures.
Ductility normalized-strainrange partitioning life relations for creep-fatigue life predictions
NASA Technical Reports Server (NTRS)
Halford, G. R.; Saltsman, J. F.; Hirschberg, M. H.
1977-01-01
Procedures based on Strainrange Partitioning (SRP) are presented for estimating the effects of environment and other influences on the high temperature, low cycle, creep fatigue resistance of alloys. It is proposed that the plastic and creep, ductilities determined from conventional tensile and creep rupture tests conducted in the environment of interest be used in a set of ductility normalized equations for making a first order approximation of the four SRP inelastic strainrange life relations. Different levels of sophistication in the application of the procedures are presented by means of illustrative examples with several high temperature alloys. Predictions of cyclic lives generally agree with observed lives within factors of three.
Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Masaoka, Yoshihisa; Tanaka, Takashi; Sato, Takuya; Gobara, Hideo; Toyooka, Shinichi; Kanazawa, Susumu
2018-05-01
To retrospectively evaluate the technical success of computed tomography fluoroscopy-guided short hookwire placement before video-assisted thoracoscopic surgery and to identify the risk factors for initial placement failure. In total, 401 short hookwire placements for 401 lesions (mean diameter 9.3 mm) were reviewed. Technical success was defined as correct positioning of the hookwire. Possible risk factors for initial placement failure (i.e., requirement for placement of an additional hookwire or to abort the attempt) were evaluated using logistic regression analysis for all procedures, and for procedures performed via the conventional route separately. Of the 401 initial placements, 383 were successful and 18 failed. Short hookwires were finally placed for 399 of 401 lesions (99.5%). Univariate logistic regression analyses revealed that in all 401 procedures only the transfissural approach was a significant independent predictor of initial placement failure (odds ratio, OR, 15.326; 95% confidence interval, CI, 5.429-43.267; p < 0.001) and for the 374 procedures performed via the conventional route only lesion size was a significant independent predictor of failure (OR 0.793, 95% CI 0.631-0.996; p = 0.046). The technical success of preoperative short hookwire placement was extremely high. The transfissural approach was a predictor initial placement failure for all procedures and small lesion size was a predictor of initial placement failure for procedures performed via the conventional route. • Technical success of preoperative short hookwire placement was extremely high. • The transfissural approach was a significant independent predictor of initial placement failure for all procedures. • Small lesion size was a significant independent predictor of initial placement failure for procedures performed via the conventional route.
Wilkinson, A E; Scrimgeour, G; Rodin, P
1972-05-01
Screening tests-absorbed fluorescent treponemal (FTA-ABS), the Reiter protein complement-fixation (RPCFT), VDRL slide test, automated reagin-and cardiolipin Wassermann reaction-were carried out on 1922 consecutive new patients attending the Whitechapel Clinic over a three-month period.Taking the FTA-ABS test results as an index, the most efficient combination of conventional tests was found to be the RPCFT and automated reagin test. The cardiolipin WR proved to be under-sensitive and of little value compared with the other tests.Forty-two per cent of the 107 sera reactive in the FTA-ABS test were not detected by the RPCFT or ART tests. An assessment based on the TPI test results and clinical findings in these patients is presented. The scope and limitations of the FTA-ABS test as a screening procedure are discussed.
Ichise, Yasuyuki; Horiuchi, Akira; Nakayama, Yoshiko; Tanaka, Naoki
2011-01-01
The ideal method to remove small colorectal polyps is unknown. We compared removal by colon snare transection without electrocautery (cold snare polypectomy) with conventional electrocautery snare polypectomy (hot polypectomy) in terms of procedure duration, difficulty in retrieving polyps, bleeding, and post-polypectomy symptoms. Patients with colorectal polyps up to 8 mm in diameter were randomized to polypectomy by cold snare technique (cold group) or conventional polypectomy (conventional group). The principal outcome measures were abdominal symptoms within 2 weeks after polypectomy. Secondary outcome measures were the rates of retrieval of colorectal polyps and bleeding. Eighty patients were randomized: cold group, n = 40 (101 polyps) and conventional group, n = 40 (104 polyps). The patients' demographic characteristics and the number and size of polyps removed were similar between the two techniques. Procedure time was significantly shorter with cold polypectomy vs. conventional polypectomy (18 vs. 25 min, p < 0.0001). Complete polyp retrieval rates were identical [96% (97/101) vs. 96% (100/104)]. No bleeding requiring hemostasis occurred in either group. Abdominal symptoms shortly after polypectomy were more common with conventional polypectomy (i.e. 20%; 8/40) than with cold polypectomy (i.e. 2.5%; 1/40; p = 0.029). Cold polypectomy was superior to conventional polypectomy in terms of procedure time and post-polypectomy abdominal symptoms. The two methods were otherwise essentially identical in terms of bleeding risk and complete polyp retrieval. Cold polypectomy is therefore the preferred method for removal of small colorectal polyps. Copyright © 2011 S. Karger AG, Basel.
Barros, Raquel R M; Novaes, Arthur B; Grisi, Márcio F M; Souza, Sérgio L S; Taba, Mário; Palioto, Daniela B
2005-01-01
Acellular dermal matrix graft (ADMG) has been used as an advantageous substitute for autogenous subepithelial connective tissue graft (SCTG). However, the surgical techniques used were primarily developed for the SCTG, and they may not be adequate for ADMG since it has a different healing process than SCTG owing to its different vascular and cellular structures. This study compared the 1-year clinical outcome of a new surgical approach with the outcome of a conventional procedure for the treatment of localized gingival recessions, both performed using the ADMG. The clinical parameters-probing depth, relative clinical attachment level, gingival recession (GR), and width of keratinized tissue-of 32 bilateral Miller Class I or II gingival recessions were assessed at baseline and 12 months postoperatively. Significant clinical changes for both surgical techniques were achieved after this period, including GR reduction from 3.4 mm presurgery to 1.2 mm at 1 year for the conventional technique and from 3.9 mm presurgery to 0.7 mm at 1 year for the new technique. The percentage of root coverage was 62.3% and 82.5% for the conventional and new techniques, respectively. Comparisons between the groups after this period by Mann-Whitney rank sum test revealed statistically significant greater reduction of GR favoring the new procedure (p = .000). Based on the results of this study, it can be concluded that a new surgical technique using an ADMG is more suitable for root coverage when compared with the conventional technique. The results revealed a statistically significant improvement in clinical performance with the ADMG approach.
Warren, R E; Zammitt, N N; Deary, I J; Frier, B M
2007-01-01
Global memory performance is impaired during acute hypoglycaemia. This study assessed whether moderate hypoglycaemia disrupts learning and recall in isolation, and utilised a novel test of prospective memory which may better reflect the role of memory in daily life than conventional tests. Thirty-six subjects with type 1 diabetes participated, 20 with normal hypoglycaemia awareness (NHA) and 16 with impaired hypoglycaemia awareness (IHA). Each underwent a hypoglycaemic clamp with target blood glucose 2.5 mmol/l. Prior to hypoglycaemia, subjects attempted to memorise instructions for a prospective memory task, and recall was assessed during hypoglycaemia. Subjects then completed the learning and immediate recall stages of three conventional memory tasks (word recall, story recall, visual recall) during hypoglycaemia. Euglycaemia was restored and delayed memory for the conventional tasks was tested. The same procedures were completed in euglycaemic control studies (blood glucose 4.5 mmol/l). Hypoglycaemia impaired performance significantly on the prospective memory task (p = 0.004). Hypoglycaemia also significantly impaired both immediate and delayed recall for the word and story recall tasks (p < 0.01 in each case). There was no significant deterioration of performance on the visual memory task. The effect of hypoglycaemia did not differ significantly between subjects with NHA and IHA. Impaired performance on the prospective memory task during hypoglycaemia demonstrates that recall is disrupted by hypoglycaemia. Impaired performance on the conventional memory tasks demonstrates that learning is also disrupted by hypoglycaemia. Results of the prospective memory task support the relevance of these findings to the everyday lives of people with diabetes.
Ishii, Kentaro; Itoi, Takao; Sofuni, Atsushi; Itokawa, Fumihide; Tsuchiya, Takayoshi; Kurihara, Toshio; Tsuji, Shujiro; Ikeuchi, Nobuhito; Umeda, Junko; Moriyasu, Fuminori
2012-01-01
Recently, controllable biopsy forceps (MTW, D°sseldorf, Germany) have been developed. This biopsy forceps were 90° adjustable. In the present study, the feasibility and efficacy of the controllable biopsy forceps were compared with those of conventional biopsy forceps in patients with biliary tract disease. A total of 27 patients with biliary tract lesions were enrolled. We evaluated the procedure time, the sample tissue size and the diagnostic accuracy. In addition, the physicians performing the procedure rated their impressions about operability into 3 classes: excellent, fair and poor. The sensitivity in distinguishing benign from malignant lesions was 71.4% (15/21) for the 90° adjustable type and 66.7% (14/21) for the conventional type. The accuracy rate was 77.8% (21/27) for the 90° adjustable type and 74.0% (20/27) for the conventional type. In terms of operability as rated by each physician, the 'excellent' rate was given more frequently to the 90° adjustable type 25.9% than for the conventional type 11.1% (p=0.047). This preliminary study showed that controllable biopsy forceps compared to conventional type biopsy forceps, despite a larger diameter, enables biopsy in a similar procedure time and its ease of use was rated better.
Gentili, Stefano; Mortali, Claudia; Mastrobattista, Luisa; Berretta, Paolo; Zaami, Simona
2016-09-10
A procedure based on headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography/mass spectrometry (GC/MS) has been developed for the determination of most commonly used drugs of abuse in sweat of drivers stopped during roadside controls. DrugWipe 5A sweat screening device was used to collect sweat by a specific pad rubbed gently over forehead skin surface. The procedure involved an acid hydrolysis, a HS-SPME extraction for drugs of abuse but Δ(9)-tetrahydrocannabinol, which was directly extracted in alkaline medium HS-SPME conditions, a GC separation of analytes by a capillary column and MS detection by electron impact ionisation. The method was linear from the limit of quantification (LOQ) to 50ng drug per pad (r(2)≥0.99), with an intra- and inter-assay precision and accuracy always less than 15% and an analytical recovery between 95.1% and 102.8%, depending on the considered analyte. Using the validated method, sweat from 60 apparently intoxicated drivers were found positive to one or more drugs of abuse, showing sweat patches testing as a viable economic and simple alternative to conventional (blood and/or urine) and non conventional (oral fluid) testing of drugs of abuse in drugged drivers. Copyright © 2016 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Duncan, William
1993-01-01
Reviews chapters of the Hague Convention on Intercountry Adoption which establish requirements for intercountry adoption, provide for a system of adoption authorities in contracting states, establish procedures to be adopted by the authorities, and provide for recognition of adoptions made under the convention. Notes that the convention guarantees…
Seol, Jung-Hwan; Cho, Byung-Hoon; Chung, Chong-Pyoung; Bae, Kwang-Shik
2006-02-01
The purpose of this study was to detect the presence of Porphyromonas endodontalis, P. gingivalis, Prevotella intermedia, P. nigrescens, and P. tannerae from clinical samples using multiplex polymerase chain reactions (PCR). Two different multiplex PCR protocols were used (one for the two Porphyromonas species and the other for the three Prevotella species), each one using a primer pair specific for each target species. The results were compared to those of the conventional culture procedures. Microbial samples were taken aseptically from 40 infected root canals and abscesses from patients. Samples were cultured in an anaerobic condition for conventional identification using a Rapid ID 32 A kit. Multiplex PCR was processed using the DNA extracted from each sample. At least one of the five species of black-pigmented bacteria (BPB) were detected in 65% (26 of 40) of the samples using multiplex PCR, and in 15% (6 of 40) using the conventional culture procedures. Multiplex PCR was more rapid, sensitive, specific, and effective in detecting BPB than the conventional culture procedures.
Reducing false negatives in clinical practice: the role of neural network technology.
Mango, L J
1996-10-01
The fact that some cervical smears result in false-negative findings is an unavoidable and unpredictable consequence of the conventional (manual microscopic) method of screening. Errors in the detection and interpretation of abnormality are cited as leading causes of false-negative cytology findings; these are random errors that are not known to correlate with any patient risk factor, which makes the false-negative findings a "silent" threat that is difficult to prevent. Described by many as a labor-intensive procedure, the microscopic evaluation of a cervical smear involves a detailed search among hundreds of thousands of cells on each smear for a possible few that may indicate abnormality. Investigations into causes of false-negative findings preceding the discovery of high-grade lesions found that many smears had very few diagnostic cells that were often very small in size. These small cells were initially overlooked or misinterpreted and repeatedly missed on rescreening. PAPNET testing is designed to supplement conventional screening by detecting abnormal cells that initially may have been missed by microscopic examination. This interactive system uses neural networks, a type of artificial intelligence well suited for pattern recognition, to automate the arduous search for abnormality. The instrument focuses the review of suspicious cells by a trained cytologist. Clinical studies indicate that PAPNET testing is sensitive to abnormality typically missed by conventional screening and that its use as a supplemental test improves the accuracy of screening.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morrow, A; Rangaraj, D; Perez-Andujar, A
2016-06-15
Purpose: This work’s objective is to determine the overlap of processes, in terms of sub-processes and time, between acceptance testing and commissioning of a conventional medical linear accelerator and to evaluate the time saved by consolidating the two processes. Method: A process map for acceptance testing for medical linear accelerators was created from vendor documentation (Varian and Elekta). Using AAPM TG-106 and inhouse commissioning procedures, a process map was created for commissioning of said accelerators. The time to complete each sub-process in each process map was evaluated. Redundancies in the processes were found and the time spent on each weremore » calculated. Results: Mechanical testing significantly overlaps between the two processes - redundant work here amounts to 9.5 hours. Many beam non-scanning dosimetry tests overlap resulting in another 6 hours of overlap. Beam scanning overlaps somewhat - acceptance tests include evaluating PDDs and multiple profiles but for only one field size while commissioning beam scanning includes multiple field sizes and depths of profiles. This overlap results in another 6 hours of rework. Absolute dosimetry, field outputs, and end to end tests are not done at all in acceptance testing. Finally, all imaging tests done in acceptance are repeated in commissioning, resulting in about 8 hours of rework. The total time overlap between the two processes is about 30 hours. Conclusion: The process mapping done in this study shows that there are no tests done in acceptance testing that are not also recommended to do for commissioning. This results in about 30 hours of redundant work when preparing a conventional linear accelerator for clinical use. Considering these findings in the context of the 5000 linacs in the United states, consolidating acceptance testing and commissioning would have allowed for the treatment of an additional 25000 patients using no additional resources.« less
Nousiainen, Markku T; Omoto, Daniel M; Zingg, Patrick O; Weil, Yoram A; Mardam-Bey, Sami W; Eward, William C
2013-02-01
: Femoral neck fractures are among the most common orthopaedic injuries impacting the health care system. Surgical management of such fractures with cannulated screws is a commonly performed procedure. The acquisition of surgical skills necessary to perform this procedure typically involves learning on real patients with fluoroscopic guidance. This study attempts to determine if a novel computer-navigated training model improves the learning of this basic surgical skill. A multicenter, prospective, randomized, and controlled study was conducted using surgical trainees with no prior experience in surgically managing femoral neck fractures. After a training session, participants underwent a pretest by performing the surgical task (screw placement) on a simulated hip fracture using fluoroscopic guidance. Immediately after, participants were randomized into either undergoing a training session using conventional fluoroscopy or computer-based navigation. Immediate posttest, retention (4 weeks later), and transfer tests were performed. Performance during the tests was determined by radiographic analysis of hardware placement. Screw placement by trainees was ultimately equal to the level of an expert surgeon with either training technique. Participants who trained with computer navigation took fewer attempts to position hardware and used less fluoroscopy time than those trained with fluoroscopy. When those trained with fluoroscopy used computer navigation at the transfer test, less fluoroscopy time and dosage was used. The concurrent augmented feedback provided by computer navigation did not affect the learning of this basic surgical skill in surgical novices. No compromise in learning occurred if the surgical novice trained with one type of technology and transferred to using the other. The findings of this study suggest that computer navigation may be safely used to train surgical novices in a basic procedure. This model avoids using both live patients and harmful radiation without a compromise in the acquisition of a 3-dimensional technical skill.
Michely, Julian A; Meyer, Markus R; Maurer, Hans H
2018-01-01
Reliable, sensitive, and comprehensive urine screening procedures by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS) with low or high resolution (HR) are of high importance for drug testing, adherence monitoring, or detection of toxic compounds. Besides conventional urine sampling, dried urine spots are of increasing interest. In the present study, the power of LC-HR-MS/MS was investigated for comprehensive drug testing in urine with or without conjugate cleavage or using dried urine spots after on-spot cleavage in comparison to established LC-MS n or GC-MS procedures. Authentic human urine samples (n = 103) were split in 4 parts. One aliquot was prepared by precipitation (UP), one by UP with conjugate cleavage (UglucP), one spot on filter paper cards and prepared by on-spot cleavage followed by liquid extraction (DUSglucE), and one worked-up by acid hydrolysis, liquid-liquid extraction, and acetylation for GC-MS analysis. The 3 series of LC-HR-MS/MS results were compared among themselves, to corresponding published LC-MS n data, and to screening results obtained by conventional GC-MS. The reference libraries used for the 3 techniques contained over 4500 spectra of parent compounds and their metabolites. The number of all detected hits (770 drug intakes) was set to 100%. The LC-HR-MS/MS approach detected 80% of the hits after UP, 89% after UglucP, and 77% after DUSglucE, which meant over one-third more hits in comparison to the corresponding published LC-MS n results with ≤49% detected hits. The GC-MS approach identified 56% of all detected hits. In conclusion, LC-HR-MS/MS provided the best screening results after conjugate cleavage and precipitation. Copyright © 2017 John Wiley & Sons, Ltd.
Ahmadi, Emad; Katnani, Husam A.; Daftari Besheli, Laleh; Gu, Qiang; Atefi, Reza; Villeneuve, Martin Y.; Eskandar, Emad; Lev, Michael H.; Golby, Alexandra J.; Gupta, Rajiv
2016-01-01
Purpose To develop an electrocorticography (ECoG) grid by using deposition of conductive nanoparticles in a polymer thick film on an organic substrate (PTFOS) that induces minimal, if any, artifacts on computed tomographic (CT) and magnetic resonance (MR) images and is safe in terms of tissue reactivity and MR heating. Materials and Methods All procedures were approved by the Animal Care and Use Committee and complied with the Public Health Services Guide for the Care and Use of Animals. Electrical functioning of PTFOS for cortical recording and stimulation was tested in two mice. PTFOS disks were implanted in two mice; after 30 days, the tissues surrounding the implants were harvested, and tissue injury was studied by using immunostaining. Five neurosurgeons rated mechanical properties of PTFOS compared with conventional grids by using a three-level Likert scale. Temperature increases during 30 minutes of 3-T MR imaging were measured in a head phantom with no grid, a conventional grid, and a PTFOS grid. Two neuroradiologists rated artifacts on CT and MR images of a cadaveric head specimen with no grid, a conventional grid, and a PTFOS grid by using a four-level Likert scale, and the mean ratings were compared between grids. Results Oscillatory local field potentials were captured with cortical recordings. Cortical stimulations in motor cortex elicited muscle contractions. PTFOS implants caused no adverse tissue reaction. Mechanical properties were rated superior to conventional grids (χ2 test, P < .05). The temperature increase during MR imaging for the three cases of no grid, PTFOS grid, and conventional grid was 3.84°C, 4.05°C, and 10.13°C, respectively. PTFOS induced no appreciable artifacts on CT and MR images, and PTFOS image quality was rated significantly higher than that with conventional grids (two-tailed t test, P < .05). Conclusion PTFOS grids may be an attractive alternative to conventional ECoG grids with regard to mechanical properties, 3-T MR heating profile, and CT and MR imaging artifacts. © RSNA, 2016 Online supplemental material is available for this article. PMID:26844363
NASA Astrophysics Data System (ADS)
Macias, F. J.; Dahl, F.; Bruland, A.
2016-05-01
The tunnel boring machine (TBM) method has become widely used and is currently an important presence within the tunnelling industry. Large investments and high geological risk are involved using TBMs, and disc cutter consumption has a great influence on performance and cost, especially in hard rock conditions. Furthermore, reliable cutter life assessments facilitate the control of risk as well as avoiding delays and budget overruns. Since abrasive wear is the most common process affecting cutter consumption, good laboratory tests for rock abrasivity assessments are needed. A new abrasivity test method by rolling disc named Rolling Indentation Abrasion Test (RIAT) has been developed. The goal of the new test design and procedure is to reproduce wear behaviour on hard rock tunnel boring in a more realistic way than the traditionally used methods. Wear by rolling contact on intact rock samples is introduced and several rock types, covering a wide rock abrasiveness range, have been tested by RIAT. The RIAT procedure indicates a great ability of the testing method to assess abrasive wear on rolling discs. In addition and to evaluate the newly developed RIAT test method, a comprehensive laboratory testing programme including the most commonly used abrasivity test methods and the mineral composition were carried out. Relationships between the achieved results from conventional testing and RIAT results have been analysed.
Measuring flood discharge in unstable stream channels using ground-penetrating radar
Spicer, K.R.; Costa, J.E.; Placzek, G.
1997-01-01
Field experiments were conducted to test the ability of ground-penetrating radar (GPR) to measure stream-channel cross sections at high flows without the necessity of placing instruments in the water. Experiments were conducted at four U.S. Geological Survey gaging stations in southwest Washington State. With the GPR antenna suspended above the water surface from a bridge or cableway, traverses were made across stream channels to collect radar profile plots of the streambed. Subsequent measurements of water depth were made using conventional depth-measuring equipment (weight and tape) and were used to calculate radar signal velocities. Other streamflow-parameter data were collected to examine their relation to radar signal velocity and to claritv of streambed definition. These initial tests indicate that GPR is capable of producing a reasonably accurate (??20%) stream-channel profile and discharge far more quickly than conventional stream-gaging procedures, while avoiding the problems and hazards associated with placing instruments in the water.
Goeree, Ron; Blackhouse, Gord; Bowen, James M; O'Reilly, Daria; Sutherland, Simone; Hopkins, Robert; Chow, Benjamin; Freeman, Michael; Provost, Yves; Dennie, Carole; Cohen, Eric; Marcuzzi, Dan; Iwanochko, Robert; Moody, Alan; Paul, Narinder; Parker, John D
2013-10-01
Conventional coronary angiography (CCA) is the standard diagnostic for coronary artery disease (CAD), but multi-detector computed tomography coronary angiography (CTCA) is a non-invasive alternative. A multi-center coverage with evidence development study was undertaken and combined with an economic model to estimate the cost-effectiveness of CTCA followed by CCA vs CCA alone. Alternative assumptions were tested in patient scenario and sensitivity analyses. CCA was found to dominate CTCA, however, CTCA was relatively more cost-effective in females, in advancing age, in patients with lower pre-test probabilities of CAD, the higher the sensitivity of CTCA and the lower the probability of undergoing a confirmatory CCA following a positive CTCA. RESULTS were very sensitive to alternative patient populations and modeling assumptions. Careful consideration of patient characteristics, procedures to improve the diagnostic yield of CTCA and selective use of CCA following CTCA will impact whether CTCA is cost-effective or dominates CCA.
High-level virtual reality simulator for endourologic procedures of lower urinary tract.
Reich, Oliver; Noll, Margarita; Gratzke, Christian; Bachmann, Alexander; Waidelich, Raphaela; Seitz, Michael; Schlenker, Boris; Baumgartner, Reinhold; Hofstetter, Alfons; Stief, Christian G
2006-06-01
To analyze the limitations of existing simulators for urologic techniques, and then test and evaluate a novel virtual reality (VR) simulator for endourologic procedures of the lower urinary tract. Surgical simulation using VR has the potential to have a tremendous impact on surgical training, testing, and certification. Endourologic procedures seem to be an ideal target for VR systems. The URO-Trainer features genuine VR, obtained from digital video footage of more than 400 endourologic diagnostic and therapeutic procedures, as well as data from cross-sectional imaging. The software offers infinite random variations of the anatomy and pathologic features for diagnosis and surgical intervention. An advanced haptic force feedback is incorporated. Virtual cystoscopy and resection of bladder tumors were evaluated by 24 medical students and 12 residents at our department. The system was assessed by more than 150 international urologists with varying experience at different conventions and workshops from March 2003 to September 2004. Because of these evaluations and constant evolutions, the final version provides a genuine representation of endourologic procedures. Objective data are generated by a tutoring system that has documented evident teaching benefits for medical students and residents in cystoscopy and treatment of bladder tumors. The URO-Trainer represents the latest generation of endoscopy simulators. Authentic visual and haptic sensations, unlimited virtual cases, and an intelligent tutoring system make this modular system an important improvement in computer-based training and quality control in urology.
Systemic inflammatory response after endoscopic (TEP) vs Shouldice groin hernia repair.
Schwab, R; Eissele, S; Brückner, U B; Gebhard, F; Becker, H P
2004-08-01
Endoscopic techniques are commonly used for many different types of surgery. It is claimed that videoendoscopic procedures have the advantage of being less traumatic and of offering higher postoperative patient comfort than conventional open techniques. The extent of tissue trauma can be evaluated on the basis of the inflammatory response observed in the wake of surgery. Available studies that have compared endoscopic and conventional techniques suggest that endoscopic cholecystectomy, laparoscopic colorectal resection, and thoracoscopic pulmonary resection have immunologic advantages over conventional approaches. The objective of this prospective study was to determine whether endoscopic hernia repair techniques are also preferable to conventional procedures and to what extent the anesthetic technique (local or general anesthesia) influences the postoperative inflammatory response. For this purpose, biochemical monitoring of cytokine activity [C-reactive protein (CRP), prostaglandin F1alpha (PGF1alpha), neopterin, interleukin-6 (IL-6)] was done prospectively in 101 patients [totally extraperitoneal approach (TEP) n=32, unilateral n=12, bilateral n=20; Shouldice n=69, local anesthesia (LA) n=23, general anesthesia (GA) n=46] before and until 3 days after surgery. The parameters IL-6 and PGF1alpha suggested that the immune trauma immediately after surgery was significantly higher in the group of patients with endoscopic hernia repair than in the group of patients who received a Shouldice repair. No significant differences were observed after the first postoperative day. A comparison between the TEP group and the patients who received conventional surgery under local anesthesia showed that the TEP approach was also associated with a higher postoperative neopterin level. Within the first 3 days after surgical intervention, bilateral endoscopic hernia repair induced no significantly higher inflammatory response than the surgical treatment of unilateral conditions. The anesthetic procedure that was used in the Shouldice operation had no significant effect on inflammatory response. Unlike other types of endoscopic surgery, the repair of groin hernias using an endoscopic technique cannot be regarded as a minimally invasive procedure that is less traumatic than conventional approaches. Instead, the conventional Shouldice procedure appears to cause the lowest inflammatory response and to be the least traumatic approach to hernia repair, especially when it is performed under local anesthesia.
Hao, Ruina; Zhang, Qiu; Xu, Zhuowen; Tang, Lijun; Yang, Zhijian; Cao, Kejiang; Li, Chunjian
2013-04-01
Computed tomography coronary angiography (CTCA) has been successfully integrated with the magnetic navigation system (MNS) to facilitate a roadmap-assisted percutaneous coronary intervention (PCI). The aim of this study was to compare this new approach of PCI versus conventional PCI regarding the difference of contrast usage, x-ray exposure, procedure success, and in-hospital expenses. Thirty-eight patients with stable coronary artery disease and coronary artery lesions of ≥70% diameter stenosis diagnosed by both pre-procedure CTCA and coronary angiography (CAG) were enrolled to receive the MNS and CT roadmap-assisted PCI. Another 38 patients were consecutively recruited to receive conventional PCI, matched with the MNS group by the vessel and lesion type base on American College of Cardiology/American Heart Association criteria. Regarding the process of the guidewire placement, wherein the technical difference of the two procedures exists, the median contrast usage for guidewire crossing was significantly lower in the MNS group than in the conventional group [0.0 mL (interquartile range [IQR], 0.0-3.0 mL) vs 5.0 mL (IQR, 3.1-6.8 mL); P<.001], with zero contrast usage in 25 of the 44 guidewire placements in the MNS group, but in none of the conventional group; the radiation dosage for guidewire crossing in the MNS group was also significantly lower than in the conventional group (235.8 μGym² [IQR, 134.9-455.1 μGym²] vs 364.4 μGym² [IQR, 223.4-547.2 μGym²]; P=.033). There were no significant differences between the two groups concerning the total contrast usage, total radiation dosage of the PCI, the procedural fees, or the overall in-hospital expenses. All of the enrolled vessels were successfully intervened in both groups. In PCI of simple lesions, the application of CT guidance and magnetic navigation had modest impacts on radiation dosage and contrast usage for wire crossing, but no impact on overall radiation dosage or contrast usage for the procedure. In addition, the use of CT roadmap and MNS was likely more expensive compared to PCI using conventional radiographic technique.
The minimal ice water caloric test compared with established vestibular caloric test procedures.
Schmäl, Frank; Lübben, Björn; Weiberg, Kerstin; Stoll, Wolfgang
2005-01-01
Caloric testing of the vestibular labyrinth is usually performed by classical caloric test procedures (CCTP) using water warmed to 30 degrees C and 44 degrees C. Ice water irrigation (4 degrees C) is usually not performed, although it might be useful as a bedside test. To verify the validity of the Minimal Ice Water Caloric Test (MIWCT), comparative video-oculographic investigations were performed in 22 healthy subjects using ice water (0.5 ml, 1.0 ml, 2 ml), CCTP, and cold air (27 degrees C). Frequency, amplitude, slow phase velocity (SPV), the onset, and the duration of nystagmus were documented. After addition of three ice cubes, the temperature of conventional tap water (16 degrees C) fell within 13 min to 4 degrees C. In pessimum position the subjects demonstrated no nystagmus response. Compared to CCTP, MIWCT was associated with a significantly later onset of nystagmus and a significant prolongation of the nystagmus reaction. In contrast to air stimulation (27 degrees C), a significant Spearman's correlation was noted between MIWCT (1 and 2 ml) and established CCTP in respect of essential nystagmus parameters (frequency, amplitude and SPV). Furthermore, MIWCT (0.5 and 1 ml) showed a higher sensitivity and specificity with regard to the detection of canal paresis based on Jongkees' formula compared to stimulation with air 27 degrees C. Thus, MIWCT appears to be a suitable procedure for bedside investigation of vestibular function outside the vestibular laboratory, e.g. in a hospital ward, where bedridden patients with vertigo occasionally require vestibular testing.
Malliet, Nicolas; Andrade, Jason G; Khairy, Paul; Thanh, Hien Kiem Nguyen; Venier, Sandrine; Dubuc, Marc; Dyrda, Katia; Guerra, Peter; Mondésert, Blandine; Rivard, Léna; Tadros, Rafik; Talajic, Mario; Thibault, Bernard; Roy, Denis; Macle, Laurent
2015-07-01
Fluoroscopic guidance is used to position catheters during cardiac ablation. We evaluated the impact of a novel nonfluoroscopic sensor-guided electromagnetic navigation system (MG) on radiation exposure during catheter ablation of atrial fibrillation (AF) or atrial flutter (AFL). A total of 134 consecutive patients referred for ablation of AF (n = 44) or AFL (n = 90) ablation were prospectively enrolled. In one group the MG system was used for nonfluoroscopic catheter positioning, whereas in the conventional group standard fluoroscopy was utilized. Fluoroscopy times were assessed for each stage of procedure and total radiation exposure was quantified. Patient characteristics were similar between the groups. The procedural end point was achieved in all. Median (interquartile range [IQR]) fluoroscopy times were 12.5 minutes (7.6, 17.4) MG group versus 21.5 minutes (15.3, 23.0) conventional group (P < 0.0001) for AF ablation, and 0.8 minutes (0.4, 2.5) MG group versus 9.9 minutes (5.1, 22.5) conventional group (P < 0.0001) for AFL ablation. Median (IQR) total radiation exposure (μGy·m(2)) was 1,107 (906, 2,033) MG group versus 2,835 (1,688, 3,855) conventional group (P = 0.0001) for AF ablation, and 161 (65, 537) MG group versus 1,651 (796, 4,569) conventional group (P < 0.0001) for AFL ablation. No difference in total procedural time was seen. The use of a novel nonfluoroscopic catheter tracking system is associated with a significant reduction in radiation exposure during AF and AFL ablation (61% and 90% reduction, respectively). In the era of heightened awareness of the importance of radiation reduction, this system represents a safe and efficient tool to decrease radiation exposure during electrophysiological ablation procedures. ©2015 Wiley Periodicals, Inc.
Alam, K; Mitrofanov, A V; Silberschmidt, V V
2011-03-01
Bone drilling is widely used in orthopaedics and surgery; it is a technically demanding surgical procedure. Recent technological improvements in this area are focused on efforts to reduce forces in bone drilling. This study focuses on forces and a torque required for conventional and ultrasonically-assisted tool penetration into fresh bovine cortical bone. Drilling tests were performed with two drilling techniques, and the influence of drilling speed, feed rate and parameters of ultrasonic vibration on the forces and torque was studied. Ultrasonically-assisted drilling (UAD) was found to reduce a drilling thrust force and torque compared to conventional drilling (CD). The mechanism behind lower levels of forces and torque was explored, using high-speed filming of a drill-bone interaction zone, and was linked to the chip shape and character of its formation. It is expected that UAD will produce holes with minimal effort and avoid unnecessary damage and accompanying pain during the incision. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
Feijó, Eduardo Damous; Caixeta, Juliana Alves; de Souza Nery, Ana Carla; Limongi, Roberto Murillo; Matayoshi, Suzana
2017-08-01
External dacryocystorhinostomy (DCR) is the gold standard surgical technique for the treatment of primary acquired nasolacrimal duct obstruction (PANDO). However, new techniques such as endoscopic DCR and transcanalicular dacryocystorhinostomy (T-DCR) are being studied in an attempt to reduce surgical time, avoid external scarring and preserve the lacrimal pump while achieving the same efficacy. The purpose of this study was to compare the efficacy between conventional T-DCR and modified transcanalicular dacryocystorhinostomy (MT-DCR) in patients with PANDO. MT-DCR is performed to remove nasal mucosa prior to laser osteotomy. This is a comparative, prospective, interventionist and randomized study. Patients with PANDO were selected to undergo MT-DCR or T-DCR by blocked randomization. PANDO was diagnosed based on clinical presentation, dye disappearance test and dacryocystography. All of the procedures were performed by the same surgery team members. Anatomical success outcome was defined as positive lacrimal syringing and functional success outcome was defined as the absence or improvement of epiphora. A total of 44 surgical procedures were performed (22 MT-DCR and 22 T-DCR). In the case of MT-DCR, the anatomical and functional success rates after 12 months were 90 and 86%, respectively. After T-DCR, these rates were 77 and 72%, respectively (p = 0.162). MT-DCR and T-DCR are both safe and fast procedures with low morbidity and well-tolerated.
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.
1988-01-01
Presented is a mathematical model derived from the Navier-Stokes equations of momentum and continuity, which may be accurately used to predict the behavior of conventionally mounted pneumatic sensing systems subject to arbitrary pressure inputs. Numerical techniques for solving the general model are developed. Both step and frequency response lab tests were performed. These data are compared with solutions of the mathematical model and show excellent agreement. The procedures used to obtain the lab data are described. In-flight step and frequency response data were obtained. Comparisons with numerical solutions of the math model show good agreement. Procedures used to obtain the flight data are described. Difficulties encountered with obtaining the flight data are discussed.
Application of MALDI-TOF mass spectrometry in clinical diagnostic microbiology.
De Carolis, Elena; Vella, Antonietta; Vaccaro, Luisa; Torelli, Riccardo; Spanu, Teresa; Fiori, Barbara; Posteraro, Brunella; Sanguinetti, Maurizio
2014-09-12
Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently emerged as a powerful technique for identification of microorganisms, changing the workflow of well-established laboratories so that its impact on microbiological diagnostics has been unparalleled. In comparison with conventional identification methods that rely on biochemical tests and require long incubation procedures, MALDI-TOF MS has the advantage of identifying bacteria and fungi directly from colonies grown on culture plates in a few minutes and with simple procedures. Numerous studies on different systems available demonstrate the reliability and accuracy of the method, and new frontiers have been explored besides microbial species level identification, such as direct identification of pathogens from positive blood cultures, subtyping, and drug susceptibility detection.
Chung, Tae Nyoung; Kim, Sun Wook; You, Je Sung; Chung, Hyun Soo
2016-01-01
Objective Tube thoracostomy (TT) is a commonly performed intensive care procedure. Simulator training may be a good alternative method for TT training, compared with conventional methods such as apprenticeship and animal skills laboratory. However, there is insufficient evidence supporting use of a simulator. The aim of this study is to determine whether training with medical simulator is associated with faster TT process, compared to conventional training without simulator. Methods This is a simulation study. Eligible participants were emergency medicine residents with very few (≤3 times) TT experience. Participants were randomized to two groups: the conventional training group, and the simulator training group. While the simulator training group used the simulator to train TT, the conventional training group watched the instructor performing TT on a cadaver. After training, all participants performed a TT on a cadaver. The performance quality was measured as correct placement and time delay. Subjects were graded if they had difficulty on process. Results Estimated median procedure time was 228 seconds in the conventional training group and 75 seconds in the simulator training group, with statistical significance (P=0.040). The difficulty grading did not show any significant difference among groups (overall performance scale, 2 vs. 3; P=0.094). Conclusion Tube thoracostomy training with a medical simulator, when compared to no simulator training, is associated with a significantly faster procedure, when performed on a human cadaver. PMID:27752610
Guipont, Vincent; Jeandin, Michel; Bansard, Sebastien; Khor, Khiam Aik; Nivard, Mariette; Berthe, Laurent; Cuq-Lelandais, Jean-Paul; Boustie, Michel
2010-12-15
An adhesion test procedure applied to plasma-sprayed hydroxyapatite (HA) coatings to measure the "LASAT threshold" (LAser Shock Adhesion test) is described. The good repeatability and minimal discrepancy of the laser-driven adhesion test data were ascertained for conventional plasma sprayed HA coatings. As a further demonstration, the procedure was applied to HA coatings with diverse characteristics on the ceramic/metal interface. Different preheating and grit blasting conditions and the presence of a thick plasma-sprayed Ti sublayer or a thin TiO(2) layer prepared by oxidation were investigated through LASAT. It was assessed that a rough surface can significantly improve the coating's bond strength. However, it was also demonstrated that a thin TiO(2) layer on a smooth Ti-6Al-4V substrate can have a major influence on adhesion as well. Preheating up to 270°C just prior to the first HA spraying pass had no effect on the adhesion strength. Further development of the procedure was done to achieve an in situ LASAT with in vitro conditions applied on HA coatings. To that end, different crystalline HA contents were soaked in simulated body fluid (SBF). Beyond the demonstration of the capability of this laser-driven adhesion test devoted to HA coatings in dry or liquid environment, the present study provided empirical information on pertinent processing characteristics that could strengthen or weaken the HA/Ti-6Al-4V bond. Copyright © 2010 Wiley Periodicals, Inc.
Mixed-Mode Decohesion Elements for Analyses of Progressive Delamination
NASA Technical Reports Server (NTRS)
Davila, Carlos G.; Camanho, Pedro P.; deMoura, Marcelo F.
2001-01-01
A new 8-node decohesion element with mixed mode capability is proposed and demonstrated. The element is used at the interface between solid finite elements to model the initiation and propagation of delamination. A single displacement-based damage parameter is used in a strain softening law to track the damage state of the interface. The method can be used in conjunction with conventional material degradation procedures to account for inplane and intra-laminar damage modes. The accuracy of the predictions is evaluated in single mode delamination tests, in the mixed-mode bending test, and in a structural configuration consisting of the debonding of a stiffener flange from its skin.
A Job-Oriented Reading Program for the Air Force: Development and Field Evaluation.
1977-05-01
spent in a conventional classroom setting, working on word power and phonics. At the end of the week, a diagnostic test is administered and the...and " soft " systems procedures in the Air Force. 3. The candidate career fields should have a large number of job incumbents, and be well represented...written information on page 47, where does the integral brake system obtain braking power ?". For an example of a complete Narrative worksheet, see Figure
Gottermeier, L; De Filippo, C L; Block, M G
1991-08-01
Hearing aid fitting involves a two-phase process of preselection and evaluation (Seewald RC and Ross M. Amplification for the Hearing Impaired 1988:213-271). The purpose of the present study was to examine alternative procedures that clinicians might use in the evaluation phase to verify the adequacy of hearing aid preselection decisions for severely and profoundly hearing-impaired listeners. Bekesy tracking, loudness rating, and conventional bracketing procedures were used to determine threshold, most comfortable listening level, and uncomfortable listening level for 10 hearing-impaired young adults. Stimuli were pulsed pure tones of 500, 1000, and 2000 Hz and filtered words. Means and standard deviations of most comfortable listening levels and uncomfortable listening levels derived from loudness judgments of the 10 subjects showed only nominal differences across procedures. However, correlation analysis (Pearson r) indicated that individuals responded to the three procedures in varying ways, producing different loudness judgments and overall dynamic ranges. Thus, test procedure may influence the clinician's final evaluation of a preselected hearing aid. Initial work suggests that closed-set response categories such as loudness rating can limit measurement variability and potentially guide the clinician's evaluation of hearing aid preselection decisions.
Morris, Paul D; Taylor, Jane; Boutong, Sara; Brett, Sarah; Louis, Amal; Heppenstall, James; Morton, Allison C; Gunn, Julian P
2016-03-01
To investigate the value of rotational coronary angiography (RoCA) in the context of percutaneous coronary intervention (PCI) planning. As a diagnostic tool, RoCA is associated with decreased patient irradiation and contrast use compared with conventional coronary angiography (CA) and provides superior appreciation of three-dimensional anatomy. However, its value in PCI remains unknown. We studied stable coronary artery disease assessment and PCI planning by interventional cardiologists. Patients underwent either RoCA or conventional CA pre-PCI for planning. These were compared with the referral CA (all conventional) in terms of quantitative lesion assessment and operator confidence. An independent panel reanalyzed all parameters. Six operators performed 127 procedures (60 RoCA, 60 conventional CA, and 7 crossed-over) and assessed 212 lesions. RoCA was associated with a reduction in the number of lesions judged to involve a bifurcation (23 vs. 30 lesions, P < 0.05) and a reduction in the assessment of vessel caliber (2.8 vs. 3.0 mm, P < 0.05). RoCA improved confidence assessing lesion length (P = 0.01), percentage stenosis (P = 0.02), tortuosity (P < 0.04), and proximity to a bifurcation (P = 0.03), particularly in left coronary artery cases. X-ray dose, contrast agent volume, and procedure duration were not significantly different. Compared with conventional CA, RoCA augments quantitative lesion assessment, enhances confidence in the assessment of coronary artery disease and the precise details of the proposed procedure, but does not affect X-ray dose, contrast agent volume, or procedure duration. © 2015 The Authors. Catheterization and Cardiovascular Interventions. Published by Wiley Periodicals, Inc.
Cost analysis of conventional facial reconstruction procedures followed by face transplantation.
Siemionow, M; Gatherwright, J; Djohan, R; Papay, F
2011-02-01
For the first time, this study analyzes the cost of multiple conventional reconstructions and face transplantation in a single patient. This patient is a 46-year-old female victim of a shotgun blast resulting in loss of multiple functional and aesthetic subunits. For over 5 years, she underwent multiple conventional reconstructions with suboptimal results. In December 2008, she became the recipient of the first U.S. face transplant. This has provided the unique opportunity to present the cost of 23 separate conventional reconstructive procedures and the first face transplant in the United States. The combined cost of conventional reconstructive procedures and the first U.S. face transplant was calculated to be $353 480 and $349 959, respectively. The combined cost posttransplant totaled $115 463. The direct cost pretransplant was $206 646, $232 893 peritransplant and $74 236 posttransplant. The two largest areas of cost utilization were surgical ($79 625; 38.5%) and nursing ($55 860; 27%), followed by anesthesia ($24 808; 12%) and pharmacy ($16 581; 8%). This study demonstrates that the cost of the first U.S. face transplant is similar to multiple conventional reconstructions. Although the cost of facial transplantation is considerable, the alleviation of psychological and physiological suffering, exceptional functional recovery and fulfillment of long-lasting hope for social reintegration may be priceless. ©2011 The Authors Journal compilation©2011 The American Society of Transplantation and the American Society of Transplant Surgeons.
Tang, Xiaowei; Gong, Wei; Deng, Zhiliang; Zhou, Jieqiong; Ren, Yutang; Zhang, Qiang; Chen, Zhenyu; Jiang, Bo
2016-01-01
Peroral endoscopic myotomy (POEM) has been developed to treat achalasia as a novel less invasive modality. We aimed to compare the efficacy and safety of conventional knife versus Hybrid knife (HK) during POEM procedure. Between June 2012 and July 2014, 31 patients underwent POEM using HK in our department (HK group), and 36 patients underwent POEM using conventional method (injection needle and triangular tip [TT] knife, TT group). Procedure-related parameters, symptom relief, adverse events were compared between two groups. There were no significant differences in the age, sex and other baseline characteristics between the two groups. The mean procedural time was significantly shorter in HK group than TT group (53.0 ± 17.2 vs. 67.6 ± 28.4 min, p = 0.015). The mean frequency of devices exchange was 4.7 ± 1.7 in HK group and 10.9 ± 1.8 in TT group (p = 0.000). No serious adverse events occurred postoperatively in both groups. At one-year follow-up, a total of 94% treatment success was achieved in all patients (93.5% in HK group and 94.4% in TT group, p = 0.877). HK in POEM can shorten the procedural time, and achieve similar treatment success compared to conventional TT knife.
Syringe size: does it matter in physician-performed procedures?
Michael, Adrian A; Moorjani, Gautam R; Peisajovich, Andres; Park, Kye S; Sibbitt, Wilmer L; Bankhurst, Arthur D
2009-03-01
We hypothesized that the size of syringe influenced needle control in physician-performed procedures. Operators were tested for their ability to control a 1-, 3-, 5-, 10-, and 20-mL syringe and equivalent sizes of the new safety device, the reciprocating procedure device (RPD), using the quantitative needle-based displacement method. Three hundred twenty clinical syringe procedures were then randomized to either a 3- or 10-mL conventional syringe or to a 3- or 10-mL RPD. Patient pain was measured with the Visual Analog Pain Scale (VAPS). Increasing syringe size was associated with the undesirable characteristic of unintended forward penetration (loss of control of the needle in the forward direction) (r(2) = 0.97, slope = 2.14, 95% CI: 1.54-2.76, P < 0.002), and unintended retraction (loss of control of the needle in the reverse direction) (r(2) = 0.97, slope 2.15, 95% CI: 1.54-2.76, P < 0.002). In addition, 2-handed operation of a syringe resulted in greater control than 1-handed operation of a syringe (P < 0.001). When 1-handed operation was required, the RPD control syringe reduced unintended penetration by 52.3% (P >or= 0.001), unintended retraction by 56.8% (P >or= 0.001), and patient pain by 54.7% (P >or= 0.001) at each device size. For greater safety and control when operating the conventional syringe, smaller syringe sizes and 2 hands instead of 1 hand should be used whenever possible. If 1-handed operation of a syringe is necessary, a safety technology like the RPD control syringe should be used.
Dimensional changes of acrylic resin denture bases: conventional versus injection-molding technique.
Gharechahi, Jafar; Asadzadeh, Nafiseh; Shahabian, Foad; Gharechahi, Maryam
2014-07-01
Acrylic resin denture bases undergo dimensional changes during polymerization. Injection molding techniques are reported to reduce these changes and thereby improve physical properties of denture bases. The aim of this study was to compare dimensional changes of specimens processed by conventional and injection-molding techniques. SR-Ivocap Triplex Hot resin was used for conventional pressure-packed and SR-Ivocap High Impact was used for injection-molding techniques. After processing, all the specimens were stored in distilled water at room temperature until measured. For dimensional accuracy evaluation, measurements were recorded at 24-hour, 48-hour and 12-day intervals using a digital caliper with an accuracy of 0.01 mm. Statistical analysis was carried out by SPSS (SPSS Inc., Chicago, IL, USA) using t-test and repeated-measures ANOVA. Statistical significance was defined at P<0.05. After each water storage period, the acrylic specimens produced by injection exhibited less dimensional changes compared to those produced by the conventional technique. Curing shrinkage was compensated by water sorption with an increase in water storage time decreasing dimensional changes. Within the limitations of this study, dimensional changes of acrylic resin specimens were influenced by the molding technique used and SR-Ivocap injection procedure exhibited higher dimensional accuracy compared to conventional molding.
Dimensional Changes of Acrylic Resin Denture Bases: Conventional Versus Injection-Molding Technique
Gharechahi, Jafar; Asadzadeh, Nafiseh; Shahabian, Foad; Gharechahi, Maryam
2014-01-01
Objective: Acrylic resin denture bases undergo dimensional changes during polymerization. Injection molding techniques are reported to reduce these changes and thereby improve physical properties of denture bases. The aim of this study was to compare dimensional changes of specimens processed by conventional and injection-molding techniques. Materials and Methods: SR-Ivocap Triplex Hot resin was used for conventional pressure-packed and SR-Ivocap High Impact was used for injection-molding techniques. After processing, all the specimens were stored in distilled water at room temperature until measured. For dimensional accuracy evaluation, measurements were recorded at 24-hour, 48-hour and 12-day intervals using a digital caliper with an accuracy of 0.01 mm. Statistical analysis was carried out by SPSS (SPSS Inc., Chicago, IL, USA) using t-test and repeated-measures ANOVA. Statistical significance was defined at P<0.05. Results: After each water storage period, the acrylic specimens produced by injection exhibited less dimensional changes compared to those produced by the conventional technique. Curing shrinkage was compensated by water sorption with an increase in water storage time decreasing dimensional changes. Conclusion: Within the limitations of this study, dimensional changes of acrylic resin specimens were influenced by the molding technique used and SR-Ivocap injection procedure exhibited higher dimensional accuracy compared to conventional molding. PMID:25584050
ERIC Educational Resources Information Center
Joint Center for Political Studies, Washington, DC.
This guide was designed to assist black delegates attending the 1976 Republican National Convention. The guide is divided into four main parts. The first part contains information on convention procedures, convention committees, and various aspects of black participation in politics. The second and third parts include the names of delegates to the…
Watterson, J.R.
1985-01-01
The presence of bacterial spores of the Bacillus cereus group in soils and stream sediments appears to be a sensitive indicator of several types of concealed mineral deposits, including vein-type gold deposits. The B. cereus assay is rapid, inexpensive, and inherently reproducible. The test, currently under investigation for its potential in mineral exploration, is recommended for use on a research basis. Among the aerobic spore-forming bacilli, only B. cereus and closely related strains produce an opaque zone in egg-yolk emulsion agar. This characteristic, also known as the Nagler of lecitho-vitellin reaction, has long been used to rapidly indentify and estimate presumptive B. cereus. The test is here adapted to permit rapid estimation of B. cereus spores in soil and stream-sediment samples. Relative standard deviation was 10.3% on counts obtained from two 40-replicate pour-plate determinations. As many as 40 samples per day can be processed. Enough procedural detail is included to permit investigation of the test in conventional geochemical laboratories using standard microbiological safety precautions. ?? 1985.
Bekas, Marcin; Pachocki, Krzysztof A; Waśniewska, Elżbieta; Bogucka, Dagmara; Magiera, Andrzej
2014-01-01
X-ray examination is associated with patient exposure to ionizing radiation. Dose values depend on the type of medical procedure used, the X-ray unit technical condition and exposure conditions selected. The aim of this study was to determine the dose value received by patients during certain conventional radiography X-ray examinations and to assess the technical condition of medical equipment used for this purpose. The study covered the total number of 118 conventional diagnostic X-ray units located in the Masovian Voivodeship. The methodology used to assess the conventional diagnostic X-ray unit technical condition and the measurement of the radiation dose rate received by patients are based on test procedures developed by the Department of Radiation Protection and Radiobiology of the National Institute of Public Health - National Institute of Hygiene (Warszawa, Poland) accredited for compliance with PN-EN 17025 standard by the Polish Centre for Accreditation. It was found that 84.7% of X-ray units fully meet the criteria set out in the Polish legislation regarding the safe use of ionizing radiation in medicine, while 15.3% of the units do not meet some of them. The broadest dose value range was recorded for adult patients. Particularly, during lateral (LATl) lumbar spine radiography the recorded entrance surface dose (ESD) values ranged from 283.5 to 7827 µGy (mean: 2183.3 µGy). It is absolutely necessary to constantly monitor the technical condition of all X-ray units, because it affects population exposure to ionizing radiation. Furthermore, it is essential to raise radiographers' awareness of the effects that ionizing radiation exposure can have on the human body.
NASA Technical Reports Server (NTRS)
Hamilton, H. B.; Strangas, E.
1980-01-01
The conventional series motor model is discussed as well as procedures for obtaining, by test, the parameters necessary for calculating performance and losses. The calculated results for operation from ripple free DC are compared with observed test results, indicating approximately 5% or less error. Experimental data indicating the influence of brush shift and chopper frequency are also presented. Both factors have a significant effect on the speed and torque relationships. The losses and loss mechanisms present in a DC series motor are examined and an attempt is made to evaluate the added losses due to harmonic currents and fluxes. Findings with respect to these losses is summarized.
Solid-state and fusion resistance spot welding of TD-NiCr sheet
NASA Technical Reports Server (NTRS)
Moore, T. J.
1973-01-01
By using specially processed TD-NiCr sheet in both 0.4-mm (0.015-in.) and 1.6-mm (0.062-in.) thicknesses and carefully selected welding procedures, solid state resistance spot welds were produced which, after postheating at 1200 C, were indistinguishable from the parent material. Stress-rupture shear tests of single-spot lap joints in 0.4-mm (0.015-in.) thick sheet showed that these welds were as strong as the parent material. Similar results were obtained in tensile-shear tests at room temperature and 1100 C and in fatigue tests. Conventional fusion spot welds in commercial sheet were unsatisfactory because of poor stress-rupture shear properties resulting from metallurgical damage to the parent material.
Gargis, Amy S; Kalman, Lisa; Lubin, Ira M
2016-12-01
Clinical microbiology and public health laboratories are beginning to utilize next-generation sequencing (NGS) for a range of applications. This technology has the potential to transform the field by providing approaches that will complement, or even replace, many conventional laboratory tests. While the benefits of NGS are significant, the complexities of these assays require an evolving set of standards to ensure testing quality. Regulatory and accreditation requirements, professional guidelines, and best practices that help ensure the quality of NGS-based tests are emerging. This review highlights currently available standards and guidelines for the implementation of NGS in the clinical and public health laboratory setting, and it includes considerations for NGS test validation, quality control procedures, proficiency testing, and reference materials. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
In vitro evaluation of an alternative method to bond molar tubes
PINZAN-VERCELINO, Célia Regina Maio; PINZAN, Arnaldo; GURGEL, Júlio de Araújo; BRAMANTE, Fausto Silva; PINZAN, Luciana Maio
2011-01-01
Despite the advances in bonding materials, many clinicians today still prefer to place bands on molar teeth. Molar bonding procedures need improvement to be widely accepted clinically. Objective The purpose of this study was to evaluate the shear bond strength when an additional adhesive layer was applied on the occlusal tooth/tube interface to provide reinforcement to molar tubes. Material and methods Sixty third molars were selected and allocated to the 3 groups: group 1 received a conventional direct bond followed by the application of an additional layer of adhesive on the occlusal tooth/tube interface, group 2 received a conventional direct bond, and group 3 received a conventional direct bond and an additional cure time of 10 s. The specimens were debonded in a universal testing machine. The results were analyzed statistically by ANOVA and Tukey’s test (α=0.05). Results Group 1 had a significantly higher (p<0.05) shear bond strength compared to groups 2 and 3. No difference was detected between groups 2 and 3 (p>0.05). Conclusions The present in vitro findings indicate that the application of an additional layer of adhesive on the tooth/tube interface increased the shear bond strength of the bonded molar tubes. PMID:21437468
Cracking of porcelain surfaces arising from abrasive grinding with a dental air turbine.
Chang, Chee W; Waddell, J Neil; Lyons, Karl M; Swain, Michael V
2011-12-01
The purpose of this in vitro study was to evaluate porcelain cracking induced by abrasive grinding with a conventional dental air turbine and abrasive diamond burs. Four commercially available porcelains were examined-Wieland ALLUX, Wieland ZIROX, IPS e.max Ceram, and IPS Empress Esthetic Veneering porcelain. Sixty discs of each porcelain type were fabricated according to manufacturer instructions, followed by an auto-glaze cycle. Abrasive grinding using fine, extra-fine, and ultra-fine diamond burs was carried out, using a conventional dental air turbine. The grinding parameters were standardized with regard to the magnitude of the force applied, rotational speed of the diamond bur, and flow rate of the water coolant. A testing apparatus was used to control the magnitude of force applied during the grinding procedure. The ground surfaces were then examined under scanning electron microscope. Cracking was seen for all porcelain types when ground with the fine bur. Cracking was not seen for specimens ground with the extra-fine or the ultra-fine bur. Wet abrasive grinding with a conventional dental air turbine and fine grit diamond burs has the potential to cause cracking in the four porcelain types tested. Similar abrasive grinding with smaller grit size particles does not cause similar observable cracking. © 2011 by the American College of Prosthodontists.
Porwal, Anand; Khandelwal, Meenakshi; Punia, Vikas; Sharma, Vivek
2017-01-01
Aim: The purpose of this study was to evaluate the effect of different denture cleansers on the color stability, surface hardness, and roughness of different denture base resins. Materials and Methods: Three denture base resin materials (conventional heat cure resin, high impact resin, and polyamide denture base resin) were immersed for 180 days in commercially available two denture cleansers (sodium perborate and sodium hypochlorite). Color, surface roughness, and hardness were measured for each sample before and after immersion procedure. Statistical Analysis: One-way analysis of variance and Tukey's post hoc honestly significant difference test were used to evaluate color, surface roughness, and hardness data before and after immersion in denture cleanser (α =0.05). Results: All denture base resins tested exhibited a change in color, surface roughness, and hardness to some degree in both denture cleansers. Polyamides resin immersed in sodium perborate showed a maximum change in color after immersion for 180 days. Conventional heat cure resin immersed in sodium hypochlorite showed a maximum change in surface roughness and conventional heat cure immersed in sodium perborate showed a maximum change in hardness. Conclusion: Color changes of all denture base resins were within the clinically accepted range for color difference. Surface roughness change of conventional heat cure resin was not within the clinically accepted range of surface roughness. The choice of denture cleanser for different denture base resins should be based on the chemistry of resin and cleanser, denture cleanser concentration, and duration of immersion. PMID:28216847
Determination of discharge during pulsating flow
Thompson, T.H.
1968-01-01
Pulsating flow in an open channel is a manifestation of unstable-flow conditions in which a series of translatory waves of perceptible magnitude develops and moves rapidly downstream. Pulsating flow is a matter of concern in the design and operation of steep-gradient channels. If it should occur at high stages in a channel designed for stable flow, the capacity of the channel may be inadequate at a discharge that is much smaller than that for which the channel was designed. If the overriding translatory wave carries an appreciable part of the total flow, conventional stream-gaging procedures cannot be used to determine the discharge; neither the conventional instrumentation nor conventional methodology is adequate. A method of determining the discharge during pulsating flow was tested in the Santa Anita Wash flood control channel in Arcadia, Calif., April 16, 1965. Observations of the dimensions and velocities of translatory waves were made during a period of controlled reservoir releases of about 100, 200, and 300 cfs (cubic feet per second). The method of computing discharge was based on (1) computation of the discharge in the overriding waves and (2) computation of the discharge in the shallow-depth, or overrun, part of the flow. Satisfactory results were obtained by this method. However, the procedure used-separating the flow into two components and then treating the shallow-depth component as though it were steady--has no theoretical basis. It is simply an expedient for use until laboratory investigation can provide a satisfactory analytical solution to the problem of computing discharge during pulsating flow. Sixteen months prior to the test in Santa Anita Wash, a robot camera had been designed .and programmed to obtain the data needed to compute discharge by the method described above. The photographic equipment had been installed in Haines Creek flood control channel in Los Angeles, Calif., but it had not been completely tested because of the infrequency of flow in that channel. Because the Santa Anita Wash tests afforded excellent data for analysis, further development of the photographic ,technique at Haines Creek was discontinued. Three methods for obtaining the data needed to compute discharge during pulsating flow are proposed. In two of the methods--the photographic method and the depth-recorder method--the dimensions and velocities of translatory waves are recorded, and discharge is then computed by the procedure developed in this report. The third method?the constant-rate-dye-dilution method--yields the discharge more directly. The discharge is computed from the dye-injection rate and the ratio of the concentration of dye in the injected solution to the concentration of dye in the water sampled at a site downstream. The three methods should be developed and tested in ,the Santa Anita Wash flood control channel under controlled conditions similar to those in the test of April 1965.
A harmonic pulse testing method for leakage detection in deep subsurface storage formations
NASA Astrophysics Data System (ADS)
Sun, Alexander Y.; Lu, Jiemin; Hovorka, Susan
2015-06-01
Detection of leakage in deep geologic storage formations (e.g., carbon sequestration sites) is a challenging problem. This study investigates an easy-to-implement frequency domain leakage detection technology based on harmonic pulse testing (HPT). Unlike conventional constant-rate pressure interference tests, HPT stimulates a reservoir using periodic injection rates. The fundamental principle underlying HPT-based leakage detection is that leakage modifies a storage system's frequency response function, thus providing clues of system malfunction. During operations, routine HPTs can be conducted at multiple pulsing frequencies to obtain experimental frequency response functions, using which the possible time-lapse changes are examined. In this work, a set of analytical frequency response solutions is derived for predicting system responses with and without leaks for single-phase flow systems. Sensitivity studies show that HPT can effectively reveal the presence of leaks. A search procedure is then prescribed for locating the actual leaks using amplitude and phase information obtained from HPT, and the resulting optimization problem is solved using the genetic algorithm. For multiphase flows, the applicability of HPT-based leakage detection procedure is exemplified numerically using a carbon sequestration problem. Results show that the detection procedure is applicable if the average reservoir conditions in the testing zone stay relatively constant during the tests, which is a working assumption under many other interpretation methods for pressure interference tests. HPT is a cost-effective tool that only requires periodic modification of the nominal injection rate. Thus it can be incorporated into existing monitoring plans with little additional investment.
Yoshida, Masao; Takizawa, Kohei; Suzuki, Sho; Koike, Yoshiki; Nonaka, Satoru; Yamasaki, Yasushi; Minagawa, Takeyoshi; Sato, Chiko; Takeuchi, Chihiro; Watanabe, Ko; Kanzaki, Hiromitsu; Morimoto, Hiroyuki; Yano, Takafumi; Sudo, Kosuke; Mori, Keita; Gotoda, Takuji; Ono, Hiroyuki
2018-05-01
The aim of this study was to clarify whether dental floss clip (DFC) traction improves the technical outcomes of endoscopic submucosal dissection (ESD). A superiority, randomized control trial was conducted at 14 institutions across Japan. Patients with single gastric neoplasm meeting the indications of the Japanese guidelines for gastric treatment were enrolled and assigned to receive conventional ESD or DFC traction-assisted ESD (DFC-ESD). Randomization was performed according to a computer-generated random sequence with stratification by institution, tumor location, tumor size, and operator experience. The primary endpoint was ESD procedure time, defined as the time from the start of the submucosal injection to the end of the tumor removal procedure. Between July 2015 and September 2016, 640 patients underwent randomization. Of these, 316 patients who underwent conventional ESD and 319 patients who underwent DFC-ESD were included in our analysis. The mean ESD procedure time was 60.7 and 58.1 minutes for conventional ESD and DFC-ESD, respectively (P = .45). Perforation was less frequent in the DFC-ESD group (2.2% vs .3%, P = .04). For lesions located in the greater curvature of the upper or middle stomach, the mean procedure time was significantly shorter in the DFC-ESD group (104.1 vs 57.2 minutes, P = .01). Our findings suggest that DFC-ESD does not result in shorter procedure time in the overall patient population, but it can reduce the risk of perforation. When selectively applied to lesions located in the greater curvature of the upper or middle stomach, DFC-ESD provides a remarkable reduction in procedure time. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Digital versus conventional techniques for pattern fabrication of implant-supported frameworks
Alikhasi, Marzieh; Rohanian, Ahmad; Ghodsi, Safoura; Kolde, Amin Mohammadpour
2018-01-01
Objective: The aim of this experimental study was to compare retention of frameworks cast from wax patterns fabricated by three different methods. Materials and Methods: Thirty-six implant analogs connected to one-piece abutments were divided randomly into three groups according to the wax pattern fabrication method (n = 12). Computer-aided design/computer-aided manufacturing (CAD/CAM) milling machine, three-dimensional printer, and conventional technique were used for fabrication of waxing patterns. All laboratory procedures were performed by an expert-reliable technician to eliminate intra-operator bias. The wax patterns were cast, finished, and seated on related abutment analogs. The number of adjustment times was recorded and analyzed by Kruskal–Wallis test. Frameworks were cemented on the corresponding analogs with zinc phosphate cement and tensile resistance test was used to measure retention value. Statistical Analysis Used: One-way analysis of variance (ANOVA) and post hoc Tukey tests were used for statistical analysis. Level of significance was set at P < 0.05. Results: The mean retentive values of 680.36 ± 21.93 N, 440.48 ± 85.98 N, and 407.23 ± 67.48 N were recorded for CAD/CAM, rapid prototyping, and conventional group, respectively. One-way ANOVA test revealed significant differences among the three groups (P < 0.001). The post hoc Tukey test showed significantly higher retention for CAD/CAM group (P < 0.001), while there was no significant difference between the two other groups (P = 0.54). CAD/CAM group required significantly more adjustments (P < 0.001). Conclusions: CAD/CAM-fabricated wax patterns showed significantly higher retention for implant-supported cement-retained frameworks; this could be a valuable help when there are limitations in the retention of single-unit implant restorations. PMID:29657528
Digital versus conventional techniques for pattern fabrication of implant-supported frameworks.
Alikhasi, Marzieh; Rohanian, Ahmad; Ghodsi, Safoura; Kolde, Amin Mohammadpour
2018-01-01
The aim of this experimental study was to compare retention of frameworks cast from wax patterns fabricated by three different methods. Thirty-six implant analogs connected to one-piece abutments were divided randomly into three groups according to the wax pattern fabrication method ( n = 12). Computer-aided design/computer-aided manufacturing (CAD/CAM) milling machine, three-dimensional printer, and conventional technique were used for fabrication of waxing patterns. All laboratory procedures were performed by an expert-reliable technician to eliminate intra-operator bias. The wax patterns were cast, finished, and seated on related abutment analogs. The number of adjustment times was recorded and analyzed by Kruskal-Wallis test. Frameworks were cemented on the corresponding analogs with zinc phosphate cement and tensile resistance test was used to measure retention value. One-way analysis of variance (ANOVA) and post hoc Tukey tests were used for statistical analysis. Level of significance was set at P < 0.05. The mean retentive values of 680.36 ± 21.93 N, 440.48 ± 85.98 N, and 407.23 ± 67.48 N were recorded for CAD/CAM, rapid prototyping, and conventional group, respectively. One-way ANOVA test revealed significant differences among the three groups ( P < 0.001). The post hoc Tukey test showed significantly higher retention for CAD/CAM group ( P < 0.001), while there was no significant difference between the two other groups ( P = 0.54). CAD/CAM group required significantly more adjustments ( P < 0.001). CAD/CAM-fabricated wax patterns showed significantly higher retention for implant-supported cement-retained frameworks; this could be a valuable help when there are limitations in the retention of single-unit implant restorations.
Arslan, Mustafa; Murat, Sema; Alp, Gulce; Zaimoglu, Ali
2018-01-01
The objectives of this in vitro study were to evaluate the flexural strength (FS), surface roughness (Ra), and hydrophobicity of polymethylmethacrylate (PMMA)-based computer-aided design/computer-aided manufacturing (CAD/CAM) polymers and to compare the properties of different CAD/CAM PMMA-based polymers with conventional heat-polymerized PMMA following thermal cycling. Twenty rectangular-shaped specimens (64 × 10 × 3.3 mm) were fabricated from three CAD/CAM PMMA-based polymers (M-PM Disc [M], AvaDent Puck Disc [A], and Pink CAD/CAM Disc Polident [P], and one conventional heat-polymerized PMMA (Promolux [C]), according to ISO 20795-1:2013 standards. The specimens were divided into two subgroups (n = 10), a control and a thermocycled group. The specimens in the thermocycled group were subjected to 5000 thermal cycling procedures (5 to 55°C; 30 s dwell times). The Ra value was measured using a profilometer. Contact angle (CA) was assessed using the sessile drop method to evaluate surface hydrophobicity. In addition, the FS of the specimens was tested in a universal testing machine at a crosshead speed of 1.0 mm/min. Surface texture of the materials was assessed using scanning electron microscope (SEM). The data were analyzed using two-way analysis of variance (ANOVA), followed by Tukey's HSD post-hoc test (α < 0.05). CAD/CAM PMMA-based polymers showed significantly higher FS than conventional heat-polymerized PMMA for each group (P < 0.001). CAD/CAM PMMA-based polymer [P] showed the highest FS, whereas conventional PMMA [C] showed the lowest FS before and after thermal cycling (P < 0.001). There were no significant differences among the Ra values of the tested denture base polymers in the control group (P > 0.05). In the thermocycled group, the lowest Ra value was observed for CAD/CAM PMMA-based polymer [M] (P < 0.001), whereas CAD/CAM PMMA-based polymers [A] and [P], and conventional PMMA [C] had similar Ra values (P > 0.05). Conventional PMMA [C] had a significantly lower CA and consequently lower hydrophobicity compared to the CAD/CAM polymers in the control group (P < 0.001). In the thermocycled group, CAD/CAM PMMA-based polymer [A] and conventional PMMA [C] had significantly higher CA, and consequently higher hydrophobicity when compared to CAD/CAM polymers [M] and [P] (P < 0.001). However, no significant differences were found among the other materials (P > 0.05). The FS and hydrophobicity of the CAD/CAM PMMA-based polymers were higher than the conventional heat-polymerized PMMA, whereas the CAD/CAM PMMA-based polymers had similar Ra values to the conventional PMMA. Thermocycling had a significant effect on FS and hydrophobicity except for the Ra of denture base materials.
Tuszynski, Tobias; Rullmann, Michael; Luthardt, Julia; Butzke, Daniel; Tiepolt, Solveig; Gertz, Hermann-Josef; Hesse, Swen; Seese, Anita; Lobsien, Donald; Sabri, Osama; Barthel, Henryk
2016-06-01
For regional quantification of nuclear brain imaging data, defining volumes of interest (VOIs) by hand is still the gold standard. As this procedure is time-consuming and operator-dependent, a variety of software tools for automated identification of neuroanatomical structures were developed. As the quality and performance of those tools are poorly investigated so far in analyzing amyloid PET data, we compared in this project four algorithms for automated VOI definition (HERMES Brass, two PMOD approaches, and FreeSurfer) against the conventional method. We systematically analyzed florbetaben brain PET and MRI data of ten patients with probable Alzheimer's dementia (AD) and ten age-matched healthy controls (HCs) collected in a previous clinical study. VOIs were manually defined on the data as well as through the four automated workflows. Standardized uptake value ratios (SUVRs) with the cerebellar cortex as a reference region were obtained for each VOI. SUVR comparisons between ADs and HCs were carried out using Mann-Whitney-U tests, and effect sizes (Cohen's d) were calculated. SUVRs of automatically generated VOIs were correlated with SUVRs of conventionally derived VOIs (Pearson's tests). The composite neocortex SUVRs obtained by manually defined VOIs were significantly higher for ADs vs. HCs (p=0.010, d=1.53). This was also the case for the four tested automated approaches which achieved effect sizes of d=1.38 to d=1.62. SUVRs of automatically generated VOIs correlated significantly with those of the hand-drawn VOIs in a number of brain regions, with regional differences in the degree of these correlations. Best overall correlation was observed in the lateral temporal VOI for all tested software tools (r=0.82 to r=0.95, p<0.001). Automated VOI definition by the software tools tested has a great potential to substitute for the current standard procedure to manually define VOIs in β-amyloid PET data analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winkler, Jon; Booten, Chuck
Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity.more » The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.« less
Ozemir, Ibrahim Ali; Bayraktar, Baris; Bayraktar, Onur; Tosun, Salih; Bilgic, Cagri; Demiral, Gokhan; Ozturk, Erman; Yigitbasi, Rafet; Alimoglu, Orhan
2015-01-01
Introduction Conventional laparoscopic procedures have been used for splenic diseases and concomitant gallbladder stones, frequently in patients with hereditary spherocytosis since 1990’s. The aim of this study is to evaluate the feasibility of single-site surgery with conventional instruments in combined procedures. Presentation of case series Six consecutive patients who scheduled for combined cholecystectomy and splenectomy because of hereditary spherocytosis or autoimmune hemolytic anemia were included this study. Both procedures were performed via trans-umbilical single-site multiport approach using conventional instruments. All procedures completed successfully without conversion to open surgery or conventional laparoscopic surgery. An additional trocar was required for only one patient. The mean operation time was 190 min (150–275 min). The mean blood loss was 185 ml (70–300 ml). Median postoperative hospital stay was two days. No perioperative mortality or major complications occurred in our series. Recurrent anemia, hernia formation or wound infection was not observed during the follow-up period. Discussion Nowadays, publications are arising about laparoscopic or single site surgery for combined diseases. Surgery for combined diseases has some difficulties owing to the placement of organs and position of the patient during laparoscopic surgery. Single site laparoscopic surgery has been proposed to have better cosmetic outcome, less postoperative pain, greater patient satisfaction and faster recovery compared to standard laparoscopy. Conclusion We consider that single-site multiport laparoscopic approach for combined splenectomy and cholecystectomy is a safe and feasible technique, after gaining enough experience on single site surgery. PMID:26708949
Moura, Renata Vasconcellos; Kojima, Alberto Noriyuki; Saraceni, Cintia Helena Coury; Bassolli, Lucas; Balducci, Ivan; Özcan, Mutlu; Mesquita, Alfredo Mikail Melo
2018-05-01
The increased use of CAD systems can generate doubt about the accuracy of digital impressions for angulated implants. The aim of this study was to evaluate the accuracy of different impression techniques, two conventional and one digital, for implants with and without angulation. We used a polyurethane cast that simulates the human maxilla according to ASTM F1839, and 6 tapered implants were installed with external hexagonal connections to simulate tooth positions 17, 15, 12, 23, 25, and 27. Implants 17 and 23 were placed with 15° of mesial angulation and distal angulation, respectively. Mini cone abutments were installed on these implants with a metal strap 1 mm in height. Conventional and digital impression procedures were performed on the maxillary master cast, and the implants were separated into 6 groups based on the technique used and measurement type: G1 - control, G2 - digital impression, G3 - conventional impression with an open tray, G4 - conventional impression with a closed tray, G5 - conventional impression with an open tray and a digital impression, and G6 - conventional impression with a closed tray and a digital impression. A statistical analysis was performed using two-way repeated measures ANOVA to compare the groups, and a Kruskal-Wallis test was conducted to analyze the accuracy of the techniques. No significant difference in the accuracy of the techniques was observed between the groups. Therefore, no differences were found among the conventional impression and the combination of conventional and digital impressions, and the angulation of the implants did not affect the accuracy of the techniques. All of the techniques exhibited trueness and had acceptable precision. The variation of the angle of the implants did not affect the accuracy of the techniques. © 2018 by the American College of Prosthodontists.
Virtual reality bronchoscopy simulation: a revolution in procedural training.
Colt, H G; Crawford, S W; Galbraith, O
2001-10-01
In the airline industry, training is costly and operator error must be avoided. Therefore, virtual reality (VR) is routinely used to learn manual and technical skills through simulation before pilots assume flight responsibilities. In the field of medicine, manual and technical skills must also be acquired to competently perform invasive procedures such as flexible fiberoptic bronchoscopy (FFB). Until recently, training in FFB and other endoscopic procedures has occurred on the job in real patients. We hypothesized that novice trainees using a VR skill center could rapidly acquire basic skills, and that results would compare favorably with those of senior trainees trained in the conventional manner. We prospectively studied five novice bronchoscopists entering a pulmonary and critical care medicine training program. They were taught to perform inspection flexible bronchoscopy using a VR bronchoscopy skill center; dexterity, speed, and accuracy were tested using the skill center and an inanimate airway model before and after 4 h of group instruction and 4 h of individual unsupervised practice. Results were compared to those of a control group of four skilled physicians who had performed at least 200 bronchoscopies during 2 years of training. Student's t tests were used to compare mean scores of study and control groups for the inanimate model and VR bronchoscopy simulator. Before-training and after-training test scores were compared using paired t tests. For comparisons between after-training novice and skilled physician scores, unpaired two-sample t tests were used. Novices significantly improved their dexterity and accuracy in both models. They missed fewer segments after training than before training, and had fewer contacts with the bronchial wall. There was no statistically significant improvement in speed or total time spent not visualizing airway anatomy. After training, novice performance equaled or surpassed that of the skilled physicians. Novices performed more thorough examinations and missed significantly fewer segments in both the inanimate and virtual simulation models. A short, focused course of instruction and unsupervised practice using a virtual bronchoscopy simulator enabled novice trainees to attain a level of manual and technical skill at performing diagnostic bronchoscopic inspection similar to those of colleagues with several years of experience. These skills were readily reproducible in a conventional inanimate airway-training model, suggesting they would also be translatable to direct patient care.
qPR: An adaptive partial-report procedure based on Bayesian inference.
Baek, Jongsoo; Lesmes, Luis Andres; Lu, Zhong-Lin
2016-08-01
Iconic memory is best assessed with the partial report procedure in which an array of letters appears briefly on the screen and a poststimulus cue directs the observer to report the identity of the cued letter(s). Typically, 6-8 cue delays or 600-800 trials are tested to measure the iconic memory decay function. Here we develop a quick partial report, or qPR, procedure based on a Bayesian adaptive framework to estimate the iconic memory decay function with much reduced testing time. The iconic memory decay function is characterized by an exponential function and a joint probability distribution of its three parameters. Starting with a prior of the parameters, the method selects the stimulus to maximize the expected information gain in the next test trial. It then updates the posterior probability distribution of the parameters based on the observer's response using Bayesian inference. The procedure is reiterated until either the total number of trials or the precision of the parameter estimates reaches a certain criterion. Simulation studies showed that only 100 trials were necessary to reach an average absolute bias of 0.026 and a precision of 0.070 (both in terms of probability correct). A psychophysical validation experiment showed that estimates of the iconic memory decay function obtained with 100 qPR trials exhibited good precision (the half width of the 68.2% credible interval = 0.055) and excellent agreement with those obtained with 1,600 trials of the conventional method of constant stimuli procedure (RMSE = 0.063). Quick partial-report relieves the data collection burden in characterizing iconic memory and makes it possible to assess iconic memory in clinical populations.
qPR: An adaptive partial-report procedure based on Bayesian inference
Baek, Jongsoo; Lesmes, Luis Andres; Lu, Zhong-Lin
2016-01-01
Iconic memory is best assessed with the partial report procedure in which an array of letters appears briefly on the screen and a poststimulus cue directs the observer to report the identity of the cued letter(s). Typically, 6–8 cue delays or 600–800 trials are tested to measure the iconic memory decay function. Here we develop a quick partial report, or qPR, procedure based on a Bayesian adaptive framework to estimate the iconic memory decay function with much reduced testing time. The iconic memory decay function is characterized by an exponential function and a joint probability distribution of its three parameters. Starting with a prior of the parameters, the method selects the stimulus to maximize the expected information gain in the next test trial. It then updates the posterior probability distribution of the parameters based on the observer's response using Bayesian inference. The procedure is reiterated until either the total number of trials or the precision of the parameter estimates reaches a certain criterion. Simulation studies showed that only 100 trials were necessary to reach an average absolute bias of 0.026 and a precision of 0.070 (both in terms of probability correct). A psychophysical validation experiment showed that estimates of the iconic memory decay function obtained with 100 qPR trials exhibited good precision (the half width of the 68.2% credible interval = 0.055) and excellent agreement with those obtained with 1,600 trials of the conventional method of constant stimuli procedure (RMSE = 0.063). Quick partial-report relieves the data collection burden in characterizing iconic memory and makes it possible to assess iconic memory in clinical populations. PMID:27580045
Nölker, Georg; Schwagten, Bruno; Deville, J Brian; Burkhardt, J David; Horton, Rodney P; Sha, Qun; Tomassoni, Gery
2016-03-01
Circular mapping catheters (CMC) are an essential tool in most atrial fibrillation ablation procedures. The Vdrive™ with V-Loop™ system enables a physician to remotely manipulate a CMC during electrophysiology studies. Our aim was to compare the clinical performance of the system to conventional CMC navigation according to efficiency and safety endpoints. A total of 120 patients scheduled to undergo a CMC study followed by pulmonary vein isolation (PVI) were included. Treatment allocation was randomized 2:1, remote navigation:manual navigation. The primary effectiveness endpoint was assessed based on both successful navigation to the targeted pulmonary vein (PV) and successful recording of PV electrograms. All PVs were treated independently within and between patients. The primary safety endpoint was assessed based on the occurrence of major adverse events (MAEs) through seven days after the study procedure. Primary effectiveness endpoints were achieved in 295/302 PVs in the Vdrive arm (97.7%) and 167/167 PVs in the manual arm (100%). Effectiveness analysis indicates Vdrive non-inferiority (pnon-inferiority = 0.0405; δ = -0.05) per the Cochran-Mantel-Haenszel test adjusted for PV correlation. Five MAEs related to the ablation procedure occurred (three in the Vdrive arm-3.9%; two in the manual arm-2.33%). No device-related MAEs were observed; safety analysis indicates Vdrive non-inferiority (pnon-inferiority = 0.0441; δ = 0.07) per the normal Z test. Remote navigation of a CMC is equivalent to manual in PVI in terms of safety and effectiveness. This allows for single-operator procedures in conjunction with a magnetically guided ablation catheter. © 2016 Wiley Periodicals, Inc.
[Percutaneously implantable aortic valve: the JenaValve concept evolution].
Figulla, Hans R; Ferrari, Markus
2006-10-01
Due to the increasing incidence of severe aortic stenosis in old and multimorbid patients, the percutaneous implantation of aortic valve-carrying stents has become an alternative to the surgical replacement of aortic valves. Starting in 1995, the authors developed a self-expanding stent which transferred the necessary forces for anchoring up to the aorta ascendens-a conception taken over from CoreValve. The further improvement of this idea over the past 11 years has led to a self-expanding, relatively short stent-valve system that is reliably positioned in the cusps of the old aortic valve and holds the old valve like a paper clip, thus transferring the holding forces physiologically. As compared to conventional systems, the sophisticated insertion catheter requires further chronic animal tests so as to represent a true alternative to the conventional surgical procedure.
Fetit, Ahmed E; Novak, Jan; Peet, Andrew C; Arvanitits, Theodoros N
2015-09-01
The aim of this study was to assess the efficacy of three-dimensional texture analysis (3D TA) of conventional MR images for the classification of childhood brain tumours in a quantitative manner. The dataset comprised pre-contrast T1 - and T2-weighted MRI series obtained from 48 children diagnosed with brain tumours (medulloblastoma, pilocytic astrocytoma and ependymoma). 3D and 2D TA were carried out on the images using first-, second- and higher order statistical methods. Six supervised classification algorithms were trained with the most influential 3D and 2D textural features, and their performances in the classification of tumour types, using the two feature sets, were compared. Model validation was carried out using the leave-one-out cross-validation (LOOCV) approach, as well as stratified 10-fold cross-validation, in order to provide additional reassurance. McNemar's test was used to test the statistical significance of any improvements demonstrated by 3D-trained classifiers. Supervised learning models trained with 3D textural features showed improved classification performances to those trained with conventional 2D features. For instance, a neural network classifier showed 12% improvement in area under the receiver operator characteristics curve (AUC) and 19% in overall classification accuracy. These improvements were statistically significant for four of the tested classifiers, as per McNemar's tests. This study shows that 3D textural features extracted from conventional T1 - and T2-weighted images can improve the diagnostic classification of childhood brain tumours. Long-term benefits of accurate, yet non-invasive, diagnostic aids include a reduction in surgical procedures, improvement in surgical and therapy planning, and support of discussions with patients' families. It remains necessary, however, to extend the analysis to a multicentre cohort in order to assess the scalability of the techniques used. Copyright © 2015 John Wiley & Sons, Ltd.
Kinoshita, Manabu; Taniguchi, Mai; Takagaki, Masatoshi; Seike, Nobuhisa; Hashimoto, Naoya; Yoshimine, Toshiki
2015-05-01
Neurosurgical patties are the most frequently used instruments during neurosurgical procedures, and their high performance is required to ensure safe operations. They must offer cushioning, water-absorbing, water-retaining, and non-tissue adherent characteristics. Here, the authors describe a revised neurosurgical patty that is superior in all respects to the conventional patty available in Japan. Patty characteristics were critically and scientifically evaluated using various in vitro assays. Moreover, a novel ex vivo evaluation system focusing on the adherent characteristics of the neurosurgical patty was developed. The proposed assay could provide benchmark data for comparing different neurosurgical patties, offering neurosurgeons objective data on the performance of patties. The newly developed patty was also evaluated in real neurosurgical settings and showed superb performance during various neurosurgical procedures.
NASA Technical Reports Server (NTRS)
Ward, J. F.
1981-01-01
Procedures were developed and tested for using KA-80A optical bar camera panoramic photography for timber typing forest land and classifying nonforest land. The study area was the south half of the Lake Tahoe Basin Management Unit. Final products from this study include four timber type map overlays on 1:24,000 orthophoto maps. The following conclusions can be drawn from this study: (1) established conventional timber typing procedures can be used on panoramic photography if the necessary equipment is available, (2) The classification and consistency results warrant further study in using panoramic photography for timber typing; and (3) timber type mapping can be done as fast or faster with panoramic photography than with resource photography while maintaining comparable accuracy.
Adams, Catherine A; Murdoch, Jennifer L; Consiglio, Maria C; Williams, Daniel M
2007-07-01
One objective of the Small Aircraft Transportation System (SATS) Project is to increase the capacity and utilization of small non-towered, non-radar equipped airports by transferring traffic management activities to an automated system and separation responsibilities to general aviation (GA) pilots. This paper describes the development of a research multi-function display (MFD) to support the interaction between pilots and an automated Airport Management Module (AMM). Preliminary results of simulation and flight tests indicate that adding the responsibility of monitoring other traffic for self-separation does not increase pilots' subjective workload levels. Pilots preferred using the enhanced MFD to execute flight procedures, reporting improved situation awareness (SA) over conventional instrument flight rules (IFR) procedures.
Piezosurgery versus conventional surgery in radicular cyst enucleation.
Kocyigit, Ismail Doruk; Atil, Fethi; Alp, Yunus Emre; Tekin, Umut; Tuz, Hakan H
2012-11-01
This study compared the use of piezosurgery and conventional surgery in radicular cyst enucleation. The study was conducted with 29 patients who were radiologically and cytologically prediagnosed with radicular cysts in the jaw region. Nineteen patients were treated using piezosurgery, and 10 were treated using conventional surgical procedures. Surgical procedures were evaluated according to the following criteria: hemorrhage, soft-tissue damage, manipulation complexity, major perforation areas on the enucleated cyst tissue, and approximate operation duration. Patients were monitored postoperatively and evaluated for hemorrhaging at 24, 48, and 72 hours following surgery. Follow-up was conducted to check for recurrences and ranged from 5 to 24 months. No complications were observed in any of the 20 patients treated using piezosurgery, although the duration of surgery was longer than expected. Of the 10 patients treated using conventional methods, hemorrhaging that affected the operation occurred in 3 cases, perforation of the cyst epithelium and difficulties in enucleation occurred in 5 cases, postoperative hemorrhage occurred in 2 cases, and recurrence was observed in 2 cases. Piezosurgery may be considered effective in procedures such as enucleation that require sensitive manipulation, despite the increase in the length of the overall surgical procedure. Given the results of the present study and the current lack of information in the literature regarding postoperative pain, infection, and long-term success rates associated with the use of piezosurgery in cyst enucleation, further study in this area is recommended.
Huang, Huajun; Xiang, Chunling; Zeng, Canjun; Ouyang, Hanbin; Wong, Kelvin Kian Loong; Huang, Wenhua
2015-12-01
We improved the geometrical modeling procedure for fast and accurate reconstruction of orthopedic structures. This procedure consists of medical image segmentation, three-dimensional geometrical reconstruction, and assignment of material properties. The patient-specific orthopedic structures reconstructed by this improved procedure can be used in the virtual surgical planning, 3D printing of real orthopedic structures and finite element analysis. A conventional modeling consists of: image segmentation, geometrical reconstruction, mesh generation, and assignment of material properties. The present study modified the conventional method to enhance software operating procedures. Patient's CT images of different bones were acquired and subsequently reconstructed to give models. The reconstruction procedures were three-dimensional image segmentation, modification of the edge length and quantity of meshes, and the assignment of material properties according to the intensity of gravy value. We compared the performance of our procedures to the conventional procedures modeling in terms of software operating time, success rate and mesh quality. Our proposed framework has the following improvements in the geometrical modeling: (1) processing time: (femur: 87.16 ± 5.90 %; pelvis: 80.16 ± 7.67 %; thoracic vertebra: 17.81 ± 4.36 %; P < 0.05); (2) least volume reduction (femur: 0.26 ± 0.06 %; pelvis: 0.70 ± 0.47, thoracic vertebra: 3.70 ± 1.75 %; P < 0.01) and (3) mesh quality in terms of aspect ratio (femur: 8.00 ± 7.38 %; pelvis: 17.70 ± 9.82 %; thoracic vertebra: 13.93 ± 9.79 %; P < 0.05) and maximum angle (femur: 4.90 ± 5.28 %; pelvis: 17.20 ± 19.29 %; thoracic vertebra: 3.86 ± 3.82 %; P < 0.05). Our proposed patient-specific geometrical modeling requires less operating time and workload, but the orthopedic structures were generated at a higher rate of success as compared with the conventional method. It is expected to benefit the surgical planning of orthopedic structures with less operating time and high accuracy of modeling.
Public participation in environmental impact assessment-implementing the Aarhus Convention
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hartley, Nicola; Wood, Christopher
This article explores the nature of public participation in the environmental impact assessment (EIA) process in the context of the potential integration of the Aarhus Convention principles into the UK EIA system. Although the Convention advocates 'early' and 'effective' participation, these terms remain undefined and questions persist about exactly how to implement the Aarhus principles. Ten practice evaluation criteria derived from the Aarhus Convention are used to analyse the public participation procedures used in four UK waste disposal EIA case studies. The paper reports the extent to which the practice evaluation criteria were fulfilled, explores the types and effectiveness ofmore » the participation methods used in the EIAs, and highlights some of the key barriers that appear to impede the execution of 'early' and 'effective' participation programmes. It concludes that the Aarhus Convention will undoubtedly lead to a strengthening of participation procedures but that the level of improvement secured will depend upon how its ideals are interpreted and incorporated into legislation and practice.« less
Ropkins, K; Beck, A J
2002-08-01
Hazard analysis by critical control points (HACCP) is a systematic approach to the identification, assessment and control of hazards. Effective HACCP requires the consideration of all hazards, i.e., chemical, microbiological and physical. However, to-date most 'in-place' HACCP procedures have tended to focus on the control of microbiological and physical food hazards. In general, the chemical component of HACCP procedures is either ignored or limited to applied chemicals, e.g., food additives and pesticides. In this paper we discuss the application of HACCP to a broader range of chemical hazards, using organic chemical contaminants as examples, and the problems that are likely to arise in the food manufacturing sector. Chemical HACCP procedures are likely to result in many of the advantages previously identified for microbiological HACCP procedures: more effective, efficient and economical than conventional end-point-testing methods. However, the high costs of analytical monitoring of chemical contaminants and a limited understanding of formulation and process optimisation as means of controlling chemical contamination of foods are likely to prevent chemical HACCP becoming as effective as microbiological HACCP.
NASA Technical Reports Server (NTRS)
Byrne, K. P.; Marshall, S. E.
1983-01-01
A procedure for experimentally determining, in terms of the particle motions, the shapes of the low order acoustic modes in enclosures is described. The procedure is based on finding differentiable functions which approximate the shape functions of the low order acoustic modes when these modes are defined in terms of the acoustic pressure. The differentiable approximating functions are formed from polynomials which are fitted by a least squares procedure to experimentally determined values which define the shapes of the low order acoustic modes in terms of the acoustic pressure. These experimentally determined values are found by a conventional technique in which the transfer functions, which relate the acoustic pressures at an array of points in the enclosure to the volume velocity of a fixed point source, are measured. The gradient of the function which approximates the shape of a particular mode in terms of the acoustic pressure is evaluated to give the mode shape in terms of the particle motion. The procedure was tested by using it to experimentally determine the shapes of the low order acoustic modes in a small rectangular enclosure.
An adaptive two-stage dose-response design method for establishing proof of concept.
Franchetti, Yoko; Anderson, Stewart J; Sampson, Allan R
2013-01-01
We propose an adaptive two-stage dose-response design where a prespecified adaptation rule is used to add and/or drop treatment arms between the stages. We extend the multiple comparison procedures-modeling (MCP-Mod) approach into a two-stage design. In each stage, we use the same set of candidate dose-response models and test for a dose-response relationship or proof of concept (PoC) via model-associated statistics. The stage-wise test results are then combined to establish "global" PoC using a conditional error function. Our simulation studies showed good and more robust power in our design method compared to conventional and fixed designs.
Ripabelli, G; Sammarco, M L; Ruberto, A; Iannitto, G; Grasso, G M
1997-06-01
The aim of the study was to compare immunomagnetic separation (IMS) and conventional selective enrichment procedures using selenite cystine broth (SC) and Rappaport-Vassiliadis broth (RV) in 137 naturally contaminated food samples (69 raw pork sausages and 68 chicken meat). The utilization of SC or IMS appeared to be the most appropriate enrichment procedure: 15 out of 18 Salmonella-positive samples (83.3%) were detected by SC and 12 (66.7%) by IMS; RV yielded only seven positive isolations (38.9%). However, RV yielded the highest count of Salmonella colonies per plate and the lowest interference by competing organisms. IMS could become a reliable alternative to standard enrichment procedures and a combined IMS and selective enrichment broth could increase the chance of Salmonella recovery.
Development of an Expert System for Representing Procedural Knowledge
NASA Technical Reports Server (NTRS)
Georgeff, Michael P.; Lansky, Amy L.
1985-01-01
A high level of automation is of paramount importance in most space operations. It is critical for unmanned missions and greatly increases the effectiveness of manned missions. However, although many functions can be automated by using advanced engineering techniques, others require complex reasoning, sensing, and manipulatory capabilities that go beyond this technology. Automation of fault diagnosis and malfunction handling is a case in point. The military have long been interested in this problem, and have developed automatic test equipment to aid in the maintenance of complex military hardware. These systems are all based on conventional software and engineering techniques. However, the effectiveness of such test equipment is severely limited. The equipment is inflexible and unresponsive to the skill level of the technicians using it. The diagnostic procedures cannot be matched to the exigencies of the current situation nor can they cope with reconfiguration or modification of the items under test. The diagnosis cannot be guided by useful advice from technicians and, when a fault cannot be isolated, no explanation is given as to the cause of failure. Because these systems perform a prescribed sequence of tests, they cannot utilize knowledge of a particular situation to focus attention on more likely trouble spots. Consequently, real-time performance is highly unsatisfactory. Furthermore, the cost of developing test software is substantial and time to maturation is excessive. Significant advances in artificial intelligence (AI) have recently led to the development of powerful and flexible reasoning systems, known as expert or knowledge-based systems. We have devised a powerful and theoretically sound scheme for representing and reasoning about procedural knowledge.
Ribas Antúnez, María de los Angeles; Girón, Blanca; Monsalvez, Iraima; Morier, Luis; Acosta, Gretel; Tejero, Yahisel; Cordero, Yanislet; Piedra, Dainelyd
2013-04-01
Rabies is a neurotropic disease that is often lethal. The early diagnosis of rabies infection is important and requires methods that allow for the isolation of the virus from animals and humans. The present study compared a modified shell vial (MSV) procedure using 24-well tissue culture plates with the mouse inoculation test (MIT), which is considered the gold standard for rabies virus isolation. Thirty brain samples (25 positive and 5 negative by the fluorescent antibody test) obtained from different animal species at the National Institute of Hygiene Rafael Rangel in Caracas, Venezuela, were studied by the MIT and MSV assays. Nine samples (36%) were positive at 24 h, 10 (40%) were positive at 48 h and six (24%) were positive at 72 h by the MSV assay. With the MIT assay, 76% were positive at six days post inoculation and 12% were positive at 12 and 18 days post inoculation. One sample that was negative according to the MSV assay was positive with MIT on the 12th day. The MSV procedure exhibited a sensitivity of 96.2%, a specificity of 100%, a positive predictive value of 100% and a negative predictive value 80%. This procedure allowed for rapid rabies virus detection. MIT can be employed as an alternative method in laboratories without tissue culture facilities.
[Sacrocolpopexy - pro laparoscopic].
Hatzinger, M; Sohn, M
2012-05-01
Innovative techniques have a really magical attraction for physicians as well as for patients. The number of robotic-assisted procedures worldwide has almost tripled from 80,000 procedures in the year 2007 to 205,000 procedures in 2010. In the same time the total number of Da Vinci surgery systems sold climbed from 800 to 1,400. Advantages, such as three-dimensional visualization, a tremor-filter, an excellent instrument handling with 6 degrees of freedom and better ergonomics, together with aggressive marketing led to a veritable flood of new Da Vinci acquisitions in the whole world. Many just took the opportunity to introduce a new instrument to save a long learning curve and start immediately in the surgical master class.If Da Vinci sacrocolpopexy is compared with the conventional laparoscopic approach, robotic-assisted sacrocolpopexy shows a significantly longer duration of the procedure, a higher need for postoperative analgesics, much higher costs and an identical functional outcome without any advantage over the conventional laparoscopic approach. Although the use of robotic-assisted systems shows a significantly lower learning curve for laparoscopic beginners, it only shows minimal advantages for the experienced laparoscopic surgeon. Therefore it remains uncertain whether robotic-assisted surgery shows a significant advantage compared to the conventional laparoscopic surgery, especially with small reconstructive laparoscopic procedures such as sacrocolpopexy.
NASA Astrophysics Data System (ADS)
Hester, David; Brownjohn, James; Bocian, Mateusz; Xu, Yan; Quattrone, Antonino
2018-05-01
This paper explores the use of wireless Inertial Measurement Units (IMU) originally developed for bio-mechanical research applications for modal testing of civil engineering infrastructure. Due to their biomechanics origin, these devices combine a triaxial accelerometer with gyroscopes and magnetometers for orientation, as well as on board data logging capability and wireless communication for optional data streaming and to coordinate synchronisation with other IMUs in a network. The motivation for application to civil structures is that their capabilities and simple operating procedures make them suitable for modal testing of many types of civil infrastructure of limited dimension including footbridges and floors while also enabling recovering of dynamic forces generated and applied to structures by moving humans. To explore their capabilities in civil applications, the IMUs are evaluated through modal tests on three different structures with increasing challenge of spatial and environmental complexity. These are, a full-scale floor mock-up in a laboratory, a short span road bridge and a seven story office tower. For each case, the results from the IMUs are compared with those from a conventional wired system to identify the limitations. The main conclusion is that the relatively high noise floor and limited communication range will not be a serious limitation in the great majority of typical civil modal test applications where convenient operation is a significant advantage over conventional wired systems.
Diagnosis of group A streptococcal infections directly from throat secretions.
Edwards, E A; Phillips, I A; Suiter, W C
1982-01-01
The diagnosis of group A streptococcal disease still relies on isolation of group A streptococcal strains on sheep blood agar followed by presumptive identification based on bacitracin sensitivity or the results of the more precise serogrouping methods such as the Lancefield precipitin test. A technique that would permit rapid identification of streptococcal infections directly from throat secretions would allow immediate appropriate antimicrobial therapy for the management of streptococcal infections to be started. We have been able to identify soluble group A antigen directly from throat secretions by using a latex agglutination test. In a clinical trial in which latex (Streptex group A) and conventional culturing techniques were used, 53 throat secretion cultures were tested: 26 were positive by both procedures, 5 were positive by culture only, 3 were positive by the latex agglutination test only, and 19 were negative by both tests. Images PMID:7042747
An alternative clinical routine for subjective refraction based on power vectors with trial frames.
María Revert, Antonia; Conversa, Maria Amparo; Albarrán Diego, César; Micó, Vicente
2017-01-01
Subjective refraction determines the final point of refractive error assessment in most clinical environments and its foundations have remained unchanged for decades. The purpose of this paper is to compare the results obtained when monocular subjective refraction is assessed in trial frames by a new clinical procedure based on a pure power vector interpretation with conventional clinical refraction procedures. An alternative clinical routine is described that uses power vector interpretation with implementation in trial frames. Refractive error is determined in terms of: (i) the spherical equivalent (M component), and (ii) a pair of Jackson Crossed Cylinder lenses oriented at 0°/90° (J 0 component) and 45°/135° (J 45 component) for determination of astigmatism. This vector subjective refraction result (VR) is compared separately for right and left eyes of 25 subjects (mean age, 35 ± 4 years) against conventional sphero-cylindrical subjective refraction (RX) using a phoropter. The VR procedure was applied with both conventional tumbling E optotypes (VR1) and modified optotypes with oblique orientation (VR2). Bland-Altman plots and intra-class correlation coefficient showed good agreement between VR, and RX (with coefficient values above 0.82) and anova showed no significant differences in any of the power vector components between RX and VR. VR1 and VR2 procedure results were similar (p ≥ 0.77). The proposed routine determines the three components of refractive error in power vector notation [M, J 0 , J 45 ], with a refraction time similar to the one used in conventional subjective procedures. The proposed routine could be helpful for inexperienced clinicians and for experienced clinicians in those cases where it is difficult to get a valid starting point for conventional RX (irregular corneas, media opacities, etc.) and for refractive situations/places with inadequate refractive facilities/equipment. © 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.
Qadri, S M; Johnson, S; Smith, J C; Zubairi, S; Gillum, R L
1981-01-01
The ability of several anaerobic bacteria to hydrolyze esculin to esculetin is used by clinical microbiologists and taxonomists in the differentiation and identification of both gram-positive and gram-negative microorganisms. Conventional methods used for determining esculin hydrolysis by anaerobic bacteria require 24 to 48 h for completion. In this paper we evaluate two procedures which yield rapid results. A total of 738 anaerobic bacteria were used in this study. A total of 99% of the esculin-hydrolyzing anaerobic bacteria gave positive results with the spot test in 1 h, whereas the other test method, the PathoTec strip test (General Diagnostics, Morris Plains, N.J.), required 4 h for 96% of the strains tested to yield positive reactions. Both tests showed a 100% specificity when compared with the standard broth test and are easy to perform, accurate, and economical. The spot test is superior to the PathoTec strip test in yielding results more rapidly. PMID:7016896
Hayashi, Nobuhide; Saegusa, Jun; Uto, Kenichi; Oyabu, Chinami; Saito, Toshiharu; Sato, Itsuko; Kawano, Seiji; Kumagai, Shunichi
2016-02-01
Antinuclear antibody (ANA) testing is indispensable for diagnosing and understanding clinical conditions of autoimmune diseases. The indirect immunofluorescence assay (IFA) is the gold standard for ANA screening, and it can detect more than 100 different antibodies, such as anti-PCNA as well as anti-cytoplasmic antibodies. However, complicated procedures of conventional IFA and visual interpretation require highly skilled laboratory staff. This study evaluates the capability, characteristics, and applicability of the recently developed ANA detection system (EUROPattern Cosmic IFA System, EPA) using HEp20-10 cells and the automated pattern recognition microscope. Findings using EPA and conventional methods were compared in 282 sera obtained from connective tissue disease patients and 250 sera from healthy individuals. The concordance of the positivity rate, antibody titer (within +/- 1 tube difference), and the accurate recognition rate of ANA patterns between the automated EPA method and the microscopic judgement of the EPA image by eye was 98.9, 97.4, and 55.3%, respectively. The EPA method showed concordance of the positivity rate as high as 93.3% and concordance of the antibody titer as high as 94.0% (within +/- 1 titer) compared with the conventional method. Regarding the four typical patterns of ANA (homogeneous, speckled, nucleolar, and centromere), large differences between the EPA and conventional methods were not observed, and the rate of concordance between the final EPA result and the conventional method was from 94.1 to 100%. The positivity rate of ANA using the EPA and conventional methods showed marked agreement among the six connective tissue diseases (SLE, MCTD, SSc, PM/DM, and SS) and healthy individuals. Although the EPA system is not considered a complete system and laboratory staff should verify the results, it is a useful system for routine ANA analysis because it contributes to ANA standardization and an efficient workflow.
Herath, Samantha; Yap, Elaine
2018-02-01
In diagnosing peripheral pulmonary lesions (PPL), radial endobronchial ultrasound (R-EBUS) is emerging as a safer method in comparison to CT-guided biopsy. Despite the better safety profile, the yield of R-EBUS remains lower (73%) than CT-guided biopsy (90%) due to the smaller size of samples. We adopted a hybrid method by adding cryobiopsy via the R-EBUS Guide Sheath (GS) to produce larger, non-crushed samples to improve diagnostic capability and enhance molecular testing. We report six prospective patients who underwent this procedure in our institution. R-EBUS samples were obtained via conventional sampling methods (needle aspiration, forceps biopsy, and cytology brush), followed by a cryobiopsy. An endobronchial blocker was placed near the planned area of biopsy in advance and inflated post-biopsy to minimize the risk of bleeding in all patients. A chest X-ray was performed 1 h post-procedure. All the PPLs were visualized with R-EBUS. The mean diameter of cryobiopsy samples was twice the size of forceps biopsy samples. In four patients, cryobiopsy samples were superior in size and the number of malignant cells per high power filed and was the preferred sample selected for mutation analysis and molecular testing. There was no pneumothorax or significant bleeding to report. Cryobiopsy samples were consistently larger and were the preferred samples for molecular testing, with an increase in the diagnostic yield and reduction in the need for repeat procedures, without hindering the marked safety profile of R-EBUS. Using an endobronchial blocker improves the safety of this procedure.
Mechanistic design concepts for conventional flexible pavements
NASA Astrophysics Data System (ADS)
Elliott, R. P.; Thompson, M. R.
1985-02-01
Mechanical design concepts for convetional flexible pavement (asphalt concrete (AC) surface plus granular base/subbase) for highways are proposed and validated. The procedure is based on ILLI-PAVE, a stress dependent finite element computer program, coupled with appropriate transfer functions. Two design criteria are considered: AC flexural fatigue cracking and subgrade rutting. Algorithms were developed relating pavement response parameters (stresses, strains, deflections) to AC thickness, AC moduli, granular layer thickness, and subgrade moduli. Extensive analyses of the AASHO Road Test flexible pavement data are presented supporting the validity of the proposed concepts.
Remote sensing of Myriophyllum spicatum L. in a shallow, eutrophic lake
NASA Technical Reports Server (NTRS)
Gustafson, T. D.; Adams, M. S.
1973-01-01
An aerial 35 mm system was used for the acquisition of vertical color and color infrared imagery of the submergent aquatic macrophytes of Lake Wingra, Wisconsin. A method of photographic interpretation of stem density classes is tested for its ability to make standing crop biomass estimates of Myriophyllum spicatum. The results of film image density analysis are significantly correlated with stem densities and standing crop biomass of Myriophyllum and with the biomass of Oedogonium mats. Photographic methods are contrasted with conventional harvest procedures for efficiency and accuracy.
Technique of the sural nerve biopsy.
Bevilacqua, Nicholas J; Rogers, Lee C; Malik, Rayaz A; Armstrong, David G
2007-01-01
A sural nerve biopsy may be useful to enable the clinician to diagnose the etiology and underlying pathology of patients presenting with symptoms of a peripheral neuropathy, when no clear underlying cause has been determined with conventional assessment such as electrophysiology or quantitative sensory testing. Given the prevalence of lower extremity neurological pathology, it is surprising that few descriptions in the peer-reviewed medical literature exist on the rationale and technique for biopsy of the sural nerve. We review the usefulness of this procedure, describe the technique, and discuss the potential complications.
Ultrasonic measurement of stress in 2219-T87 aluminum plate
NASA Technical Reports Server (NTRS)
Clotfelter, W. N.; Risch, E. R.
1976-01-01
The basic relationship of ultrasonic signal velocity to directional subsurface stress is reviewed. Inappropriateness of dependency on a single correlative value of constant for a three dimensional stress field in metallic materials is discussed. Implementation of conventional ultrasonic nondestructive testing capabilities integrated to provide a composite technique for the measurement of orthogonal stress components is described, and the procedures for performing the preparatory calibration and subsequent stress field measurements are presented. In conclusion, the prime effect of stress on ultrasonic signal velocity occurs only in the direction of material excitation or particle motion.
Advanced Gas Turbine (AGT) powertrain system development for automotive applications
NASA Technical Reports Server (NTRS)
1982-01-01
A gas turbine powertrain for automobiles with reduced fuel consumption and reduced environmental impact is investigated. The automotive gas turbine, when installed in an automobile (3000 pounds inertia weight), provides a CFDC fuel economy of 42.8 miles per gallon based on EPA test procedures and diesel No. 2 fuel. The AGT powered vehicle substantially gives the same overall vehicle driveability and performance as a comparable production vehicle powered by a conventional spark ignition powertrain system. The emissions are less than federal standards, and a variety of fuels can be used.
A novel directional asymmetric sampling search algorithm for fast block-matching motion estimation
NASA Astrophysics Data System (ADS)
Li, Yue-e.; Wang, Qiang
2011-11-01
This paper proposes a novel directional asymmetric sampling search (DASS) algorithm for video compression. Making full use of the error information (block distortions) of the search patterns, eight different direction search patterns are designed for various situations. The strategy of local sampling search is employed for the search of big-motion vector. In order to further speed up the search, early termination strategy is adopted in procedure of DASS. Compared to conventional fast algorithms, the proposed method has the most satisfactory PSNR values for all test sequences.
NASA Technical Reports Server (NTRS)
Hepner, George F.; Logan, Thomas; Ritter, Niles; Bryant, Nevin
1990-01-01
Recent research has shown an artificial neural network (ANN) to be capable of pattern recognition and the classification of image data. This paper examines the potential for the application of neural network computing to satellite image processing. A second objective is to provide a preliminary comparison and ANN classification. An artificial neural network can be trained to do land-cover classification of satellite imagery using selected sites representative of each class in a manner similar to conventional supervised classification. One of the major problems associated with recognition and classifications of pattern from remotely sensed data is the time and cost of developing a set of training sites. This reseach compares the use of an ANN back propagation classification procedure with a conventional supervised maximum likelihood classification procedure using a minimal training set. When using a minimal training set, the neural network is able to provide a land-cover classification superior to the classification derived from the conventional classification procedure. This research is the foundation for developing application parameters for further prototyping of software and hardware implementations for artificial neural networks in satellite image and geographic information processing.
Percutaneous dilatational versus conventional surgical tracheostomy in intensive care patients
Youssef, Tarek F.; Ahmed, Mohamed Rifaat; Saber, Aly
2011-01-01
Background: Tracheostomy is usually performed in patients with difficult weaning from mechanical ventilation or some catastrophic neurologic insult. Conventional tracheostomy involves dissection of the pretracheal tissues and insertion of the tracheostomy tube into the trachea under direct vision. Percutaneous dilatational tracheostomy is increasingly popular and has gained widespread acceptance in many intensive care unit and trauma centers. Aim: Aim of the study was to compare percutaneous dilatational tracheostomy versus conventional tracheostomy in intensive care patients. Patients and Methods: 64 critically ill patients admitted to intensive care unit subjected to tracheostomy and randomly divided into two groups; percutaneous dilatational tracheostomy and conventional tracheostomy. Results: Mean duration of the procedure was similar between the two procedures while the mean size of tracheostomy tube was smaller in percutaneous technique. In addition, the Lowest SpO2 during procedure, PaCO2 after operation and intra-operative bleeding for both groups were nearly similar without any statistically difference. Postoperative infection after 7 days seen to be statistically lowered and the length of scar tend to be smaller among PDT patients. Conclusion: PDT technique is effective and safe as CST with low incidence of post operative complication. PMID:22361497
USDA-ARS?s Scientific Manuscript database
Sire conception rate (SCR), a service-sire fertility evaluation implemented in August 2008, is based on up to 7 conventional-semen breedings for parities 1 through 5 (Ccow). The same procedure was used to derive SCR for other types of breedings: sexed semen for cows (Scow) and conventional semen and...
Alternative Refractive Surgery Procedures
... alternative refractive surgery procedures to LASIK . Wavefront-Guided LASIK Before surgery, the excimer laser is programmed with ... precise "sculpting" of each unique cornea. In conventional LASIK , this programming is based on the patient's vision ...
Edward, Joseph; Aziz, Mubarak A; Madhu Usha, Arjun; Narayanan, Jyothi K
2017-12-01
Extractions are routine procedures in dental surgery. Traditional extraction techniques use a combination of severing the periodontal attachment, luxation with an elevator, and removal with forceps. A new technique of extraction of maxillary third molar is introduced in this study-Joedds technique, which is compared with the conventional technique. One hundred people were included in the study, the people were divided into two groups by means of simple random sampling. In one group conventional technique of maxillary third molar extraction was used and on second Joedds technique was used. Statistical analysis was carried out with student's t test. Analysis of 100 patients based on parameters showed that the novel joedds technique had minimal trauma to surrounding tissues, less tuberosity and root fractures and the time taken for extraction was <2 min while compared to other group of patients. This novel technique has proved to be better than conventional third molar extraction technique, with minimal complications. If Proper selection of cases and right technique are used.
ICAP - An Interactive Cluster Analysis Procedure for analyzing remotely sensed data
NASA Technical Reports Server (NTRS)
Wharton, S. W.; Turner, B. J.
1981-01-01
An Interactive Cluster Analysis Procedure (ICAP) was developed to derive classifier training statistics from remotely sensed data. ICAP differs from conventional clustering algorithms by allowing the analyst to optimize the cluster configuration by inspection, rather than by manipulating process parameters. Control of the clustering process alternates between the algorithm, which creates new centroids and forms clusters, and the analyst, who can evaluate and elect to modify the cluster structure. Clusters can be deleted, or lumped together pairwise, or new centroids can be added. A summary of the cluster statistics can be requested to facilitate cluster manipulation. The principal advantage of this approach is that it allows prior information (when available) to be used directly in the analysis, since the analyst interacts with ICAP in a straightforward manner, using basic terms with which he is more likely to be familiar. Results from testing ICAP showed that an informed use of ICAP can improve classification, as compared to an existing cluster analysis procedure.
Automatic colonic lesion detection and tracking in endoscopic videos
NASA Astrophysics Data System (ADS)
Li, Wenjing; Gustafsson, Ulf; A-Rahim, Yoursif
2011-03-01
The biology of colorectal cancer offers an opportunity for both early detection and prevention. Compared with other imaging modalities, optical colonoscopy is the procedure of choice for simultaneous detection and removal of colonic polyps. Computer assisted screening makes it possible to assist physicians and potentially improve the accuracy of the diagnostic decision during the exam. This paper presents an unsupervised method to detect and track colonic lesions in endoscopic videos. The aim of the lesion screening and tracking is to facilitate detection of polyps and abnormal mucosa in real time as the physician is performing the procedure. For colonic lesion detection, the conventional marker controlled watershed based segmentation is used to segment the colonic lesions, followed by an adaptive ellipse fitting strategy to further validate the shape. For colonic lesion tracking, a mean shift tracker with background modeling is used to track the target region from the detection phase. The approach has been tested on colonoscopy videos acquired during regular colonoscopic procedures and demonstrated promising results.
Jung, Yunho; Kato, Masayuki; Lee, Jongchan; Gromski, Mark A; Chuttani, Ram; Matthes, Kai
2013-11-01
A prototype endoscope was designed to improve visualization and dissection of tissue with the use of 2 working channels with different deflections. To evaluate the efficacy and operability of a prototype endoscope in comparison with a conventional double-channel endoscope for rectal endoscopic submucosal dissection (ESD). Randomized, prospective, controlled, ex vivo study. Academic medical center. A total of 80 standardized artificial lesions measuring 3 × 3 cm were created approximately 5 cm from the anal verge in fresh ex vivo porcine colorectal specimens. Two endoscopists each completed 20 cases with the prototype endoscope and 20 cases with the conventional endoscope. An independent observer recorded procedure time, specimen size, en bloc resection, and perforation rate. For the ESD novice, the mean submucosal dissection time (10.5 ± 3.8 vs 14.9 ± 7.3 minutes; P = .024) and total procedure time (18.1 ± 5.2 vs 23.6 ± 8.2 minutes; P = .015) were significantly shorter in the prototype group in comparison with the conventional group. For the ESD expert, there was no significant difference between the mean circumferential resection, submucosal dissection, and total procedure time (prototype group 14.2 ± 6.0 minutes, conventional group 14.2 ± 8.8 minutes; P = .992). The overall perforation and en bloc resection rates were not significantly different between groups. Ex vivo study. In this ex vivo prospective comparison study, there was a technical advantage for the ESD novice with the prototype endoscope that resulted in a shorter procedure time, which was not observed for cases performed by the ESD expert. Copyright © 2013 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Phillips, E. P.
1974-01-01
Specimens of Ti-6Al-4V titanium alloy sheet in the annealed and the solution-treated and aged heat-treatment condition were exposed outdoors at ambient and 560 K (550 F) temperatures to determine the effect of outdoor exposure on fatigue life. Effects of exposure were determined by comparing fatigue lives of exposed specimens to those of unexpected specimens. Two procedures for fatigue testing the exposed specimens were evaluated: (1) fatigue tests conducted outdoors by applying 1200 load cycles per week until failure occurred and (2) conventional fatigue tests (continuous cycling until failure occurred) conducted indoors after outdoor exposure under static load. The exposure period ranged from 9 to 28 months for the outdoor fatigue-test group and was 24 months for the static-load group. All fatigue tests were constant-amplitude bending of specimens containing a drilled hole (stress concentration factor of 1.6). The results of the tests indicate that the fatigue lives of solution-treated and aged specimens were significantly reduced by the outdoor exposure at 560 K but not by the exposure at ambient temperature. Fatigue lives of the annealed specimens were essentially unaffected by the outdoor exposure at either temperature. The two test procedures - outdoor fatigue test and indoor fatigue test after outdoor exposure - led to the same conclusions about exposure effects.
Calvo-Guirado, José Luis; Delgado-Peña, Jorge; Maté-Sánchez, Jose E; Mareque Bueno, Javier; Delgado-Ruiz, Rafael Arcesio; Romanos, Georgios E
2015-07-01
To evaluate a new hybrid drilling protocol, by the analysis of thermal changes in vitro, and their effects in the crestal bone loss and bone-to-implant contact in vivo. Temperature changes during simulated osteotomies with a hybrid drilling technique (biologic plus simplified) (test) versus an incremental drilling technique (control) were investigated. One hundred and twenty random osteotomies were performed (60 by group) in pig ribs up to 3.75-mm-diameter drill to a depth of 10 mm. Thermal changes and time were recorded by paired thermocouples. In a parallel experiment, bilateral mandibular premolars P2, P3, P4, and first molar M1 were extracted from six dogs. After 2-month healing, implant sites were randomly prepared using either of the drilling techniques. Forty eight implants of 3.75 mm diameter and 10 mm length were inserted. The dogs were euthanized at 30 and 90 days, and crestal bone loss (CBL) and bone-to-implant contact (BIC) were evaluated. The control group showed maximum temperatures of 35.3 °C ± 1.8 °C, ΔT of 10.4 °C, and a mean time of 100 s/procedure; meanwhile, the test group showed maximum temperatures of 36.7 °C ± 1.2 °C, ΔT of 8.1 °C, and a mean time of 240 s/procedure. After 30 days, CBL values for both groups (test: 1.168 ± 0.194 mm; control: 1.181 ± 0.113 mm) and BIC values (test: 43 ± 2.8%; control: 45 ± 1.3%) were similar, without significant differences (P > 0.05). After 90 days, CBL (test: 1.173 ± 0.187 mm; control: 1.205 ± 0.122 mm) and BIC (test: 64 ± 3.3%; control: 64 ± 2.4%) values were similar, without significant differences (P > 0.05). The BIC values were increased at 90 days in both groups compared with the 30-day period (P < 0.05). Within the limitations of this study, the new hybrid protocol for the preparation of the implant bed without irrigation, increase the temperature similarly to the incremental conventional protocol, and requires twice the time for the completion of the drilling procedure in vitro. Crestal bone loss and bone-to-implant contact in the hybrid drilling protocol are comparable with the conventional drilling protocol and do not affect the osseointegration process in vivo. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Conventional and two step sintering of PZT-PCN ceramics
NASA Astrophysics Data System (ADS)
Keshavarzi, Mostafa; Rahmani, Hooman; Nemati, Ali; Hashemi, Mahdieh
2018-02-01
In this study, PZT-PCN ceramic was made via sol-gel seeding method and effects of conventional sintering (CS) as well as two-step sintering (TSS) were investigated on microstructure, phase formation, density, dielectric and piezoelectric properties. First, high quality powder was achieved by seeding method in which the mixture of Co3O4 and Nb2O5 powder was added to the prepared PZT sol to form PZT-PCN gel. After drying and calcination, pyrochlore free PZT-PCN powder was synthesized. Second, CS and TSS were applied to achieve dense ceramic. The optimum temperature used for 2 h of conventional sintering was obtained at 1150 °C; finally, undesired ZrO2 phase formed in CS procedure was removed successfully with TSS procedure and dielectric and piezoelectric properties were improved compared to the CS procedure. The best electrical properties obtained for the sample sintered by TSS in the initial temperature of T 1 = 1200 °C and secondary temperature of T 2 = 1000 °C for 12 h.
Lince-Deroche, Naomi; Phiri, Jane; Michelow, Pam; Smith, Jennifer S.; Firnhaber, Cindy
2015-01-01
Background South Africa has high rates of HIV and HPV and high incidence and mortality from cervical cancer. However, cervical cancer is largely preventable when early screening and treatment are available. We estimate the costs and cost-effectiveness of conventional cytology (Pap), visual inspection with acetic acid (VIA) and HPV DNA testing for detecting cases of CIN2+ among HIV-infected women currently taking antiretroviral treatment at a public HIV clinic in Johannesburg, South Africa. Methods Method effectiveness was derived from a validation study completed at the clinic. Costs were estimated from the provider perspective using micro-costing between June 2013-April 2014. Capital costs were annualized using a discount rate of 3%. Two different service volume scenarios were considered. Threshold analysis was used to explore the potential for reducing the cost of HPV DNA testing. Results VIA was least costly in both scenarios. In the higher volume scenario, the average cost per procedure was US$ 3.67 for VIA, US$ 8.17 for Pap and US$ 54.34 for HPV DNA. Colposcopic biopsies cost on average US$ 67.71 per procedure. VIA was least sensitive but most cost-effective at US$ 17.05 per true CIN2+ case detected. The cost per case detected for Pap testing was US$ 130.63 using a conventional definition for positive results and US$ 187.52 using a more conservative definition. HPV DNA testing was US$ 320.09 per case detected. Colposcopic biopsy costs largely drove the total and per case costs. A 71% reduction in HPV DNA screening costs would make it competitive with the conservative Pap definition. Conclusions Women need access to services which meet their needs and address the burden of cervical dysplasia and cancer in this region. Although most cost-effective, VIA may require more frequent screening due to low sensitivity, an important consideration for an HIV-positive population with increased risk for disease progression. PMID:26569487
Lince-Deroche, Naomi; Phiri, Jane; Michelow, Pam; Smith, Jennifer S; Firnhaber, Cindy
2015-01-01
South Africa has high rates of HIV and HPV and high incidence and mortality from cervical cancer. However, cervical cancer is largely preventable when early screening and treatment are available. We estimate the costs and cost-effectiveness of conventional cytology (Pap), visual inspection with acetic acid (VIA) and HPV DNA testing for detecting cases of CIN2+ among HIV-infected women currently taking antiretroviral treatment at a public HIV clinic in Johannesburg, South Africa. Method effectiveness was derived from a validation study completed at the clinic. Costs were estimated from the provider perspective using micro-costing between June 2013-April 2014. Capital costs were annualized using a discount rate of 3%. Two different service volume scenarios were considered. Threshold analysis was used to explore the potential for reducing the cost of HPV DNA testing. VIA was least costly in both scenarios. In the higher volume scenario, the average cost per procedure was US$ 3.67 for VIA, US$ 8.17 for Pap and US$ 54.34 for HPV DNA. Colposcopic biopsies cost on average US$ 67.71 per procedure. VIA was least sensitive but most cost-effective at US$ 17.05 per true CIN2+ case detected. The cost per case detected for Pap testing was US$ 130.63 using a conventional definition for positive results and US$ 187.52 using a more conservative definition. HPV DNA testing was US$ 320.09 per case detected. Colposcopic biopsy costs largely drove the total and per case costs. A 71% reduction in HPV DNA screening costs would make it competitive with the conservative Pap definition. Women need access to services which meet their needs and address the burden of cervical dysplasia and cancer in this region. Although most cost-effective, VIA may require more frequent screening due to low sensitivity, an important consideration for an HIV-positive population with increased risk for disease progression.
Malmström, Marlene; Ivarsson, Bodil; Klefsgård, Rosemarie; Persson, Kerstin; Jakobsson, Ulf; Johansson, Jan
2016-12-01
Following oesophagectomy, a major surgical procedure, it is known that patients suffer from severely reduced quality of life and have an unmet need for postoperative support. Still, there is a lack of research testing interventions aiming to enhance the patients' life situation after this surgical procedure. The aim of the study was to evaluate the effect of a nurse led telephone supportive care programme on quality of life (QOL), received information and the number of healthcare contacts compared to conventional care following oesophageal resection for cancer. The study was designed as a randomized controlled trial (RCT) aiming to test the effect of a nurse led telephone supportive care program compared to conventional care. Patient assessments were conducted at discharge, 2 weeks, 2, 4 and 6 months after discharge and comprised evaluation of QOL, received information and the number of health care contacts. Statistical testing were conducted with repeated measurements analysis of variance to test if there were differences between the groups during follow-up. The results show that the intervention group was significantly more satisfied with received information for items concerning the information they received about things to do to help yourself, written information and for the global information score. The control group scored significantly higher on the item regarding wishing to receive more information and wish to receive less information. No effect of the intervention was shown on QOL or number of health care contacts. Proactive nurse-led telephone follow-up has a significant positive impact on the patients' experience of received information. This is likely to have a positive effect on their ability to cope with a life that may include remaining side effects and adverse symptoms for a long time after surgery. Copyright © 2016 Elsevier Ltd. All rights reserved.
Comparative study between manual injection intraosseous anesthesia and conventional oral anesthesia.
Peñarrocha-Oltra, D; Ata-Ali, J; Oltra-Moscardó, M-J; Peñarrocha-Diago, M-A; Peñarrocha, M
2012-03-01
To compare intraosseous anesthesia (IA) with the conventional oral anesthesia techniques. A simple-blind, prospective clinical study was carried out. Each patient underwent two anesthetic techniques: conventional (local infiltration and locoregional anesthetic block) and intraosseous, for respective dental operations. In order to allow comparison of IA versus conventional anesthesia, the two operations were similar and affected the same two teeth in opposite quadrants. A total of 200 oral anesthetic procedures were carried out in 100 patients. The mean patient age was 28.6±9.92 years. Fifty-five vestibular infiltrations and 45 mandibular blocks were performed. All patients were also subjected to IA. The type of intervention (conservative or endodontic) exerted no significant influence (p=0.58 and p=0.62, respectively). The latency period was 8.52±2.44 minutes for the conventional techniques and 0.89±0.73 minutes for IA - the difference being statistically significant (p<0.05). Regarding patient anesthesia sensation, the infiltrative techniques lasted a maximum of one hour, the inferior alveolar nerve blocks lasted between 1-3 hours, and IA lasted only 2.5 minutes - the differences being statistically significant (p≤0.0000, Φ=0.29). Anesthetic success was recorded in 89% of the conventional procedures and in 78% of the IA. Most patients preferred IA (61%)(p=0.0032). The two anesthetic procedures have been compared for latency, duration of anesthetic effect, anesthetic success rate and patient preference. Intraosseous anesthesia has been shown to be a technique to be taken into account when planning conservative and endodontic treatments.
Baur, Heiner; Groppa, Alessia Severina; Limacher, Regula; Radlinger, Lorenz
2016-02-02
Maximum strength and rate of force development (RFD) are 2 important strength characteristics for everyday tasks and athletic performance. Measurements of both parameters must be reliable. Expensive isokinetic devices with isometric modes are often used. The possibility of cost-effective measurements in a practical setting would facilitate quality control. The purpose of this study was to assess the reliability of measurements of maximum isometric strength (Fmax) and RFD on a conventional leg press. Sixteen subjects (23 ± 2 y, 1.68 ± 0.05 m, 59 ± 5 kg) were tested twice within 1 session. After warm-up, subjects performed 2 times 5 trials eliciting maximum voluntary isometric contractions on an instrumented leg press (1- and 2-legged randomized). Fmax (N) and RFD (N/s) were extracted from force-time curves. Reliability was determined for Fmax and RFD by calculating the intraclass correlation coefficient (ICC), the test-retest variability (TRV), and the bias and limits of agreement. Reliability measures revealed good to excellent ICCs of .80-.93. TRV showed mean differences between measurement sessions of 0.4-6.9%. The systematic error was low compared with the absolute mean values (Fmax 5-6%, RFD 1-4%). The implementation of a force transducer into a conventional leg press provides a viable procedure to assess Fmax and RFD. Both performance parameters can be assessed with good to excellent reliability allowing quality control of interventions.
Complex task performance in Cyberspace. Surgical procedures in a telepresence environment.
Bowersox, J C; LaPorta, A J; Cordts, P R; Bhoyrul, S; Shah, A
1996-01-01
To assess the capabilities of our fully functional, prototype telepresence surgery system, experienced surgeons performed complete operative procedures on live, anesthetized pigs. Cholecystectomy, the prototypical procedure for evaluating the integration of surgical skills, was successfully performed in six animals. There were no aborted attempts or complications. Other procedures completed included gastrotomy and enterotomy closures, anastomosis of the small intestine, and nephrectomy. No specific training was required for using the telepresence surgery system, and the "feel" of the system was described as intuitive. Operative times were longer than required in conventional, open surgery, most likely the result of the four degrees of freedom available in the manipulators of the current-generation system. Force feedback and high-resolution, stereoscopic video input facilitated performance. Surgeons operating through a first-generation telepresence system can achieve technical results equivalent to those obtained in conventional surgery.
Code of Federal Regulations, 2013 CFR
2013-04-01
.... CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY CARGO CONTAINER.... This chapter establishes procedures for certifying containers and road vehicles in conformance with the Customs Convention on Containers (1956) (TIAS 6634), the Customs Convention on the International Transport...
Code of Federal Regulations, 2011 CFR
2011-04-01
.... CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY CARGO CONTAINER.... This chapter establishes procedures for certifying containers and road vehicles in conformance with the Customs Convention on Containers (1956) (TIAS 6634), the Customs Convention on the International Transport...
Code of Federal Regulations, 2010 CFR
2010-04-01
.... CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY CARGO CONTAINER.... This chapter establishes procedures for certifying containers and road vehicles in conformance with the Customs Convention on Containers (1956) (TIAS 6634), the Customs Convention on the International Transport...
Code of Federal Regulations, 2012 CFR
2012-04-01
.... CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY CARGO CONTAINER.... This chapter establishes procedures for certifying containers and road vehicles in conformance with the Customs Convention on Containers (1956) (TIAS 6634), the Customs Convention on the International Transport...
Code of Federal Regulations, 2014 CFR
2014-04-01
.... CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY CARGO CONTAINER.... This chapter establishes procedures for certifying containers and road vehicles in conformance with the Customs Convention on Containers (1956) (TIAS 6634), the Customs Convention on the International Transport...
Mori, Genki; Nonaka, Satoru; Oda, Ichiro; Abe, Seiichiro; Suzuki, Haruhisa; Yoshinaga, Shigetaka; Nakajima, Takeshi; Saito, Yutaka
2015-01-01
Background and study aims: Endoscopic submucosal dissection (ESD) using insulation-tipped knives (IT knives) to treat gastric lesions located on the greater curvature of the gastric body remains technically challenging because of the associated bleeding, control of which can be difficult and time consuming. To eliminate these difficulties, we developed a novel strategy which we have called the “near-side approach method” and assessed its utility. Patients and methods: We reviewed patients who underwent ESD for solitary early gastric cancer located on the greater curvature of the gastric body from January 2003 to September 2014. The technical results of ESD were compared between the group treated with the novel near-side approach method and the group treated with the conventional method. Results: This study included 238 patients with 238 lesions, 118 of which were removed using the near-side approach method and 120 of which were removed using the conventional method. The median procedure time was 92 minutes for the near-side approach method and 120 minutes for the conventional method. The procedure time was significantly shorter in the near-side approach method arm. Although, the procedure time required by an experienced endoscopist was not significantly different between the two groups (100 vs. 110 minutes), the near-side approach group showed significantly shorter procedure time for a less-experienced endoscopist (90 vs. 120 minutes). Conclusions: The near-side approach method appears to require less time to complete gastric ESD than the conventional method using IT knives for technically challenging lesions located on the greater curvature of the gastric body, especially if the procedure is performed by less-experienced endoscopists. PMID:26528496
Da Vinci Robotic Surgery in a Pediatric Hospital.
Mattioli, Girolamo; Pini Prato, Alessio; Razore, Barbara; Leonelli, Lorenzo; Pio, Luca; Avanzini, Stefano; Boscarelli, Alessandro; Barabino, Paola; Disma, Nicola Massimo; Zanaboni, Clelia; Garzi, Alfredo; Martigli, Sofia Paola; Buffi, Nicolò Maria; Rosati, Ubaldo; Petralia, Paolo
2017-05-01
Since the use of robotic surgery (RS) revolutionized some adult surgery procedures such as radical prostatectomy, it has been progressively and increasingly introduced in pediatric surgery. The aim of this study is to evaluate how the Da Vinci ® Si HD technology impacts a pediatric public hospital and to define the use of a robotic system in pediatric surgery. We prospectively included patients older than 6 months of age undergoing RS or conventional minimal access surgery (MAS): Study period ranges between February 2015 and April 2016. Surgical indications were defined after a detailed disease-specific diagnostic work-up. We analyzed surgical outcomes and the most relevant economic aspects. The 30-day postoperative complications were evaluated and retrospectively collected in an electronic database. From February 2015 to April 2016, we performed 77 procedures with RS and 84 with conventional MAS in patients with a median age of 77 and 98 months at surgery and a median weight of 20 and 23 kg, respectively. Median operative times were 130 and 109 minutes, respectively. We observed 9.1% of complications in the RS group and 6% in the MAS group and the difference was not statistically significant. Of note, 8 out of 77 RS procedures would have been performed with open classic surgery in case of conversion or failure of RS. This initial experience confirms that RS is as safe and effective as conventional MAS. A number of selected procedures performed with RS would only benefit from this approach, as it is not suitable for conventional MAS. Although economically demanding, in particular for a pediatric hospital, we firmly believe that centralization of care would allow pediatric surgeons adopting RS to perform complex reconstructive surgical procedures with great advantages for the patients and a minimal increase in overall costs for the health system.
Sasamori, Hitomi; Ohmura, Yu; Kubo, Takuya; Yoshida, Takayuki; Yoshioka, Mitsuhiro
2018-05-02
Immaturity in impulse control among adolescents could result in substance abuse, criminal involvement, and suicide. The brains of adolescents and adults are anatomically, neurophysiologically, and pharmacologically different. Therefore, preclinical models of adolescent impulsivity are required to screen drugs for adolescents and elucidate the neural mechanisms underlying age-related differences in impulsivity. The conventional 3- or 5-choice serial reaction time task, which is a widely used task to assess impulsivity in adult rodents, cannot be used for young mice because of two technical problems: impaired growth caused by food restriction and the very long training duration. To overcome these problems, we altered the conventional training process, optimizing the degree of food restriction for young animals and shortening the training duration. We found that almost all basal performance levels were similar between the novel and conventional procedures. We also confirmed the pharmacological validity of our results: the 5-hydroxytryptamine 2C (5-HT 2C ) receptor agonist Ro60-0175 (0.6 mg/kg, subcutaneous) reduced the occurrence of premature responses, whereas the 5-HT 2C receptor antagonist SB242084 (0.5 mg/kg intraperitoneal) increased their occurrence, consistent with results of previous studies using conventional procedures. Furthermore, we detected age-related differences in impulsivity using the novel procedure: adolescent mice were found to be more impulsive than adult mice, congruent with the results of human studies. Thus, the new procedure enables the assessment of impulsivity in adolescent mice and facilitates a better understanding of the neurophysiological/pharmacological properties of adolescents. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Modified Peritoneal Dialysis Catheter Insertion: Comparison with a Conventional Method.
Lee, Yong Kyu; Yang, Pil-Sung; Park, Kyoung Sook; Choi, Kyu Hun; Kim, Beom Seok
2015-07-01
The conventional trocar and cannula method in peritoneal dialysis (PD) catheter insertion has its limitation in clinical setting. The aim of this study was to compare a modified method for percutaneous PD catheter insertion with the conventional method, and demonstrate advantages of the modified method. Patients at a single center who had percutaneous PD catheters inserted by nephrologists from January 2006 until September 2012, using either a modified method (group M) or the conventional trocar and cannula method (group C), were retrospectively analyzed, in terms of baseline characteristics, complications experienced up to 3 months after the procedure, and the suitability of the procedure for patients. Group M included 82 subjects, while group C included 66 cases. The overall early complication rate in group M (1.2%) was significantly lower than that in group C (19.7%) (p<0.001). The catheter revision rate during timeframe for early complications was significantly lower in group M (0%) than in group C (6.1%) (p=0.024). When comparing Procedure time (1 h 3 min±16 min vs. 1 h 36 min±19 min, p<0.01), immediate post-procedural pain (2.43±1.80 vs. 3.14±2.07, p<0.05), and post-procedure days until ambulation (3.95±1.13 days vs. 6.17±1.34 days, p<0.01), group M was significantly lower than group C. There was no significant difference in total hospitalization period (14.71±7.05 days vs. 13.86±3.7 days). Our modified PD catheter insertion method shows its advantages in early complication rate, early complications revision rate, and the patients' conveniences.
Modified Peritoneal Dialysis Catheter Insertion: Comparison with a Conventional Method
Lee, Yong Kyu; Yang, Pil-Sung; Park, Kyoung Sook; Choi, Kyu Hun
2015-01-01
Purpose The conventional trocar and cannula method in peritoneal dialysis (PD) catheter insertion has its limitation in clinical setting. The aim of this study was to compare a modified method for percutaneous PD catheter insertion with the conventional method, and demonstrate advantages of the modified method. Materials and Methods Patients at a single center who had percutaneous PD catheters inserted by nephrologists from January 2006 until September 2012, using either a modified method (group M) or the conventional trocar and cannula method (group C), were retrospectively analyzed, in terms of baseline characteristics, complications experienced up to 3 months after the procedure, and the suitability of the procedure for patients. Results Group M included 82 subjects, while group C included 66 cases. The overall early complication rate in group M (1.2%) was significantly lower than that in group C (19.7%) (p<0.001). The catheter revision rate during timeframe for early complications was significantly lower in group M (0%) than in group C (6.1%) (p=0.024). When comparing Procedure time (1 h 3 min±16 min vs. 1 h 36 min±19 min, p<0.01), immediate post-procedural pain (2.43±1.80 vs. 3.14±2.07, p<0.05), and post-procedure days until ambulation (3.95±1.13 days vs. 6.17±1.34 days, p<0.01), group M was significantly lower than group C. There was no significant difference in total hospitalization period (14.71±7.05 days vs. 13.86±3.7 days). Conclusion Our modified PD catheter insertion method shows its advantages in early complication rate, early complications revision rate, and the patients' conveniences. PMID:26069120
Pelviureteric obstruction in children: conventional pyeloplasty is superior to endo-urology.
Ahmed, S; Crankson, S; Sripathi, V
1998-09-01
Hydronephrosis secondary to pelviureteric junction (PUJ) obstruction is common in infancy and childhood. Pyeloplasty has until recently been the accepted method of management, but alternative endo-urological techniques have evolved in the last decade. Published results of conventional pyeloplasty for primary PUJ obstruction in children were compared with published results of endo-urological procedures. Sixty-six pyeloplasties were performed in 61 children in a 6-year period. During a similar period, 63 primary endo-urological procedures were reported in the literature. The success rate after pyeloplasty was 95.5% compared with 65% after endo-urology. Conventional pyeloplasty is superior to endo-urology and should remain the gold standard for the treatment of primary PUJ obstruction in children.
Diode laser surgery. Ab interno and ab externo versus conventional surgery in rabbits.
Karp, C L; Higginbotham, E J; Edward, D P; Musch, D C
1993-10-01
Fibroblastic proliferation of subconjunctival tissues remains a primary mechanism of failure in filtration surgery. Minimizing the surgical manipulation of episcleral tissues may reduce scarring. Laser sclerostomy surgery involves minimal tissue dissection, and is gaining attention as a method of potentially improving filter duration in high-risk cases. Twenty-five New Zealand rabbits underwent filtration surgery in one eye, and the fellow eye remained as the unoperated control. Ten rabbits underwent ab externo diode laser sclerostomy surgery, ten underwent ab interno diode sclerostomy surgery, and five had posterior sclerostomy procedures. Filtration failure was defined as a less-than-4-mmHg intraocular pressure (IOP) difference between the operative and control eyes. The mean time to failure for the ab externo, ab interno, and conventional posterior sclerostomy techniques measured 17.4 +/- 11.5, 13.1 +/- 6.7, and 6.0 +/- 3.1 days, respectively. In a comparison of the laser-treated groups with the conventional procedure, the time to failure was significantly longer (P = 0.02) for the ab externo filter. The mean ab interno sclerostomy duration was longer than the posterior lip procedure, but this difference was not statistically significant (P = 0.15). The overall level of IOP reduction was similar in the three groups. These data suggest that diode laser sclerostomy is a feasible technique in rabbits, and the ab externo approach resulted in longer filter duration than the conventional posterior lip procedure in this model.
Body mass index is not associated with sperm-zona pellucida binding ability in subfertile males.
Sermondade, Nathalie; Dupont, Charlotte; Faure, Céline; Boubaya, Marouane; Cédrin-Durnerin, Isabelle; Chavatte-Palmer, Pascale; Sifer, Christophe; Lévy, Rachel
2013-09-01
Lifestyle factors, such as weight and nutritional status may affect male fertility, including sperm fertilization ability. The objective of this retrospective study was to evaluate the association between body mass index (BMI) and sperm-zona pellucida binding ability assessed according to the zona binding (ZB) test, which has been described to be a relevant diagnostic tool for the prediction of in vitro fertilization (IVF) ability. Three hundred and six male patients from couples diagnosed with primary idiopathic or mild male factor infertility were included. Correlations between BMI and semen parameters according to ZB test indices were assessed, together with frequencies of positive and negative tests across the BMI categories. In this selected population, BMI was not related to conventional semen parameters or sperm quality assessed according to the ability of spermatozoa to bind to the zona pellucida. The previously described poor outcomes of IVF procedures in cases of male obesity could be due to other sperm defects, such as alterations of sperm capacitation or acrosome reaction. The link between male BMI and biological outcomes during IVF procedures, such as fertilization rates, should be further evaluated.
Masjedi, Milad; Andrews, Barry; Cobb, Justin
2013-01-01
Robotic systems have been shown to improve unicompartmental knee arthroplasty (UKA) component placement accuracy compared to conventional methods when used by experienced surgeons. We aimed to determine whether inexperienced UKA surgeons can position components accurately using robotic assistance when compared to conventional methods and to demonstrate the effect repetition has on accuracy. Sixteen surgeons were randomised to an active constraint robot or conventional group performing three UKAs over three weeks. Implanted component positions and orientations were compared to planned component positions in six degrees of freedom for both femoral and tibial components. Mean procedure time decreased for both robot (37.5 mins to 25.7 mins) (P = 0.002) and conventional (33.8 mins to 21.0 mins) (P = 0.002) groups by attempt three indicating the presence of a learning curve; however, neither group demonstrated changes in accuracy. Mean compound rotational and translational errors were lower in the robot group compared to the conventional group for both components at all attempts for which rotational error differences were significant at every attempt. The conventional group's positioning remained inaccurate even with repeated attempts although procedure time improved. In comparison, by limiting inaccuracies inherent in conventional equipment, robotic assistance enabled surgeons to achieve precision and accuracy when positioning UKA components irrespective of their experience. PMID:23862069
Hybrid procedure in living donor liver transplantation.
Soyama, A; Takatsuki, M; Hidaka, M; Adachi, T; Kitasato, A; Kinoshita, A; Natsuda, K; Baimakhanov, Z; Kuroki, T; Eguchi, S
2015-04-01
We have previously reported a hybrid procedure that uses a combination of laparoscopic mobilization of the liver and subsequent hepatectomy under direct vision in living donor liver transplantation (LDLT). We present the details of this hybrid procedure and the outcomes of the procedure. Between January 1997 and August 2014, 204 LDLTs were performed at Nagasaki University Hospital. Among them, 67 recent donors underwent hybrid donor hepatectomy. Forty-one donors underwent left hemihepatectomy, 25 underwent right hemihepatectomy, and 1 underwent posterior sectionectomy. First, an 8-cm subxiphoid midline incision was made; laparoscopic mobilization of the liver was then achieved with a hand-assist through the midline incision under the pneumoperitoneum. Thereafter, the incision was extended up to 12 cm for the right lobe and posterior sector graft and 10 cm left lobe graft procurement. Under direct vision, parenchymal transection was performed by means of the liver-hanging maneuver. The hybrid procedure for LDLT recipients was indicated only for selected cases with atrophic liver cirrhosis without a history of upper abdominal surgery, significant retroperitoneal collateral vessels, or hypertrophic change of the liver (n = 29). For total hepatectomy and splenectomy, the midline incision was sufficiently extended. All of the hybrid donor hepatectomies were completed without an extra subcostal incision. No significant differences were observed in the blood loss or length of the operation compared with conventional open procedures. All of the donors have returned to their preoperative activity level, with fewer wound-related complaints compared with those treated with the use of the conventional open procedure. In recipients treated with the hybrid procedure, no clinically relevant drawbacks were observed compared with the recipients treated with a regular Mercedes-Benz-type incision. Our hybrid procedure was safely conducted with the same quality as the conventional open procedure in both LDLT donors and recipients. Copyright © 2015 Elsevier Inc. All rights reserved.
Human factors flight trial analysis for 3D SVS: part II
NASA Astrophysics Data System (ADS)
Schiefele, Jens; Howland, Duncan; Maris, John; Pschierer, Christian; Wipplinger, Patrick; Meuter, Michael
2005-05-01
This paper describes flight trials performed in Centennial, CO using a Piper Cheyenne owned and operated by Marinvent. The goal of the flight trial was to evaluate the objective performance of pilots using conventional paper charts or a 3D SVS display. Six pilots flew thirty-six approaches to the Colorado Springs airport to accomplish this goal. As dependent variables, positional accuracy and situational awareness probe (SAP) statistics were measured while analysis was conducted by an ANOVA test. In parallel, all pilots answered subjective Cooper-Harper, NASA TLX, situation awareness rating technique (SART), Display Readability Rating, Display Flyability Rating and debriefing questionnaires. Three different settings (paper chart, electronic navigation chart, 3D SVS display) were evaluated in a totally randomized manner. This paper describes the comparison between the conventional paper chart and the 3D SVS display. The 3D SVS primary flight display provides a depiction of primary flight data as well as a 3D depiction of airports, terrain and obstacles. In addition, a 3D dynamic channel visualizing the selected approach procedure can be displayed. The result shows that pilots flying the 3D SVS display perform no worse than pilots with the conventional paper chart. Flight technical error and workload are lower, situational awareness is equivalent with conventional paper charts.
Mokhtari, Negar; Shirazi, Alireza-Sarraf
2017-01-01
Background Techniques with adequate accuracy of working length determination along with shorter duration of treatment in pulpectomy procedure seems to be essential in pediatric dentistry. The aim of the present study was to evaluate the accuracy of root canal length measurement with Root ZX II apex locator and rotary system in pulpectomy of primary teeth. Material and Methods In this randomized control clinical trial complete pulpectomy was performed on 80 mandibular primary molars in 80, 4-6-year-old children. The study population was randomly divided into case and control groups. In control group conventional pulpectomy was performed and in the case group working length was determined by electronic apex locator Root ZXII and instrumented with Mtwo rotary files. Statistical evaluation was performed using Mann-Whitney and Chi-Square tests (P<0.05). Results There were no significant differences between electronic apex locator Root ZXII and conventional method in accuracy of root canal length determination. However significantly less time was needed for instrumenting with rotary files (P=0.000). Conclusions Considering the comparable results in accuracy of root canal length determination and the considerably shorter instrumentation time in Root ZXII apex locator and rotary system, it may be suggested for pulpectomy in primary molar teeth. Key words:Rotary technique, conventional technique, pulpectomy, primary teeth. PMID:29302280
Mokhtari, Negar; Shirazi, Alireza-Sarraf; Ebrahimi, Masoumeh
2017-11-01
Techniques with adequate accuracy of working length determination along with shorter duration of treatment in pulpectomy procedure seems to be essential in pediatric dentistry. The aim of the present study was to evaluate the accuracy of root canal length measurement with Root ZX II apex locator and rotary system in pulpectomy of primary teeth. In this randomized control clinical trial complete pulpectomy was performed on 80 mandibular primary molars in 80, 4-6-year-old children. The study population was randomly divided into case and control groups. In control group conventional pulpectomy was performed and in the case group working length was determined by electronic apex locator Root ZXII and instrumented with Mtwo rotary files. Statistical evaluation was performed using Mann-Whitney and Chi-Square tests ( P <0.05). There were no significant differences between electronic apex locator Root ZXII and conventional method in accuracy of root canal length determination. However significantly less time was needed for instrumenting with rotary files ( P =0.000). Considering the comparable results in accuracy of root canal length determination and the considerably shorter instrumentation time in Root ZXII apex locator and rotary system, it may be suggested for pulpectomy in primary molar teeth. Key words: Rotary technique, conventional technique, pulpectomy, primary teeth.
Non-invasive peripheral nerve stimulation via focused ultrasound in vivo
NASA Astrophysics Data System (ADS)
Downs, Matthew E.; Lee, Stephen A.; Yang, Georgiana; Kim, Seaok; Wang, Qi; Konofagou, Elisa E.
2018-02-01
Focused ultrasound (FUS) has been employed on a wide range of clinical applications to safely and non-invasively achieve desired effects that have previously required invasive and lengthy procedures with conventional methods. Conventional electrical neuromodulation therapies that are applied to the peripheral nervous system (PNS) are invasive and/or non-specific. Recently, focused ultrasound has demonstrated the ability to modulate the central nervous system and ex vivo peripheral neurons. Here, for the first time, noninvasive stimulation of the sciatic nerve eliciting a physiological response in vivo is demonstrated with FUS. FUS was applied on the sciatic nerve in mice with simultaneous electromyography (EMG) on the tibialis anterior muscle. EMG signals were detected during or directly after ultrasound stimulation along with observable muscle contraction of the hind limb. Transecting the sciatic nerve downstream of FUS stimulation eliminated EMG activity during FUS stimulation. Peak-to-peak EMG response amplitudes and latency were found to be comparable to conventional electrical stimulation methods. Histology along with behavioral and thermal testing did not indicate damage to the nerve or surrounding regions. The findings presented herein demonstrate that FUS can serve as a targeted, safe and non-invasive alternative to conventional peripheral nervous system stimulation to treat peripheral neuropathic diseases in the clinic.
Influence of pellet seating on the external ballistic parameters of spring-piston air guns.
Werner, Ronald; Schultz, Benno; Frank, Matthias
2016-09-01
In firearm examiners' and forensic specialists' casework as well as in air gun proof testing, reliable measurement of the weapon's muzzle velocity is indispensable. While there are standardized and generally accepted procedures for testing the performance of air guns, the method of seating the diabolo pellets deeper into the breech of break barrel spring-piston air guns has not found its way into standardized test procedures. The influence of pellet seating on the external ballistic parameters was investigated using ten different break barrel spring-piston air guns. Test shots were performed with the diabolo pellets seated 2 mm deeper into the breech using a pellet seater. The results were then compared to reference shots with conventionally loaded diabolo pellets. Projectile velocity was measured with a high-precision redundant ballistic speed measurement system. In eight out of ten weapons, the muzzle energy increased significantly when the pellet seater was used. The average increase in kinetic energy was 31 % (range 9-96 %). To conclude, seating the pellet even slightly deeper into the breech of spring-piston air guns might significantly alter the muzzle energy. Therefore, it is strongly recommended that this effect is taken into account when accurate and reliable measurements of air gun muzzle velocity are necessary.
Experimental high gradient testing of a 17.1 GHz photonic band-gap accelerator structure
Munroe, Brian J.; Zhang, JieXi; Xu, Haoran; ...
2016-03-29
In this paper, we report the design, fabrication, and high gradient testing of a 17.1 GHz photonic band-gap (PBG) accelerator structure. Photonic band-gap (PBG) structures are promising candidates for electron accelerators capable of high-gradient operation because they have the inherent damping of high order modes required to avoid beam breakup instabilities. The 17.1 GHz PBG structure tested was a single cell structure composed of a triangular array of round copper rods of radius 1.45 mm spaced by 8.05 mm. The test assembly consisted of the test PBG cell located between conventional (pillbox) input and output cells, with input power ofmore » up to 4 MW from a klystron supplied via a TM 01 mode launcher. Breakdown at high gradient was observed by diagnostics including reflected power, downstream and upstream current monitors and visible light emission. The testing procedure was first benchmarked with a conventional disc-loaded waveguide structure, which reached a gradient of 87 MV=m at a breakdown probability of 1.19 × 10 –1 per pulse per meter. The PBG structure was tested with 100 ns pulses at gradient levels of less than 90 MV=m in order to limit the surface temperature rise to 120 K. The PBG structure reached up to 89 MV=m at a breakdown probability of 1.09 × 10 –1 per pulse per meter. These test results show that a PBG structure can simultaneously operate at high gradients and low breakdown probability, while also providing wakefield damping.« less
Kalavathi, M; Sachin, Bhuvana; Prasanna, B G; Shreeharsha, T V; Praveen, B; Ragher, Mallikarjuna
2016-02-01
The thermal expansion of the investment can be restricted by the metal casting ring because the thermal expansion of the ring is less than that of the investment. The ringless casting procedure is in use in clinical dentistry, though there is little scientific data to support its use in fixed partial dentures. In this study, marginal discrepancy of castings produced with the ringless casting technique and the conventional technique using the metal rings were compared. A total of 30 wax patterns were fabricated directly on a metal die. Optical stereomicroscope was used to measure the marginal discrepancy between the metal die and wax patterns. A total of 15 castings were invested using Bellavest T phosphate-bonded investment with the ringless technique and 15 were invested with the same investment with a metal ring; 30 castings were produced using a nickel-chromium ceramo-metal alloy. The internal surface of the castings was not modified and seated with finger pressure. The vertical marginal discrepancy was measured using an optical stereomicroscope at a magnification of 100x. The data obtained were statistically analyzed using students t-test (paired t-test and unpaired t-test). The castings of the ringless technique provided less vertical marginal discrepancy (240.56 ± 45.81 μ) than the castings produced with the conventional metal ring technique (281.98± 53.05 μ). The difference was statistically significant. The ringless casting technique had produced better marginal accuracy compared with conventional casting technique. Ringless casting system can be used routinely for clinical purpose.
NASA Astrophysics Data System (ADS)
Romînu, Roxana Otilia; Sinescu, Cosmin; Romînu, Mihai; Negrutiu, Meda; Laissue, Philippe; Mihali, Sorin; Cuc, Lavinia; Hughes, Michael; Bradu, Adrian; Podoleanu, Adrian
2008-09-01
Bonding has become a routine procedure in several dental specialties - from prosthodontics to conservative dentistry and even orthodontics. In many of these fields it is important to be able to investigate the bonded interfaces to assess their quality. All currently employed investigative methods are invasive, meaning that samples are destroyed in the testing procedure and cannot be used again. We have investigated the interface between human enamel and bonded ceramic brackets non-invasively, introducing a combination of new investigative methods - optical coherence tomography (OCT) and confocal microscopy (CM). Brackets were conventionally bonded on conditioned buccal surfaces of teeth The bonding was assessed using these methods. Three dimensional reconstructions of the detected material defects were developed using manual and semi-automatic segmentation. The results clearly prove that OCT and CM are useful in orthodontic bonding investigations.
Development of a Test Facility for Air Revitalization Technology Evaluation
NASA Technical Reports Server (NTRS)
Lu, Sao-Dung; Lin, Amy; Campbell, Melissa; Smith, Frederick
2006-01-01
An active fault tolerant control (FTC) law is generally sensitive to false identification since the control gain is reconfigured for fault occurrence. In the conventional FTC law design procedure, dynamic variations due to false identification are not considered. In this paper, an FTC synthesis method is developed in order to consider possible variations of closed-loop dynamics under false identification into the control design procedure. An active FTC synthesis problem is formulated into an LMI optimization problem to minimize the upper bound of the induced-L2 norm which can represent the worst-case performance degradation due to false identification. The developed synthesis method is applied for control of the longitudinal motions of FASER (Free-flying Airplane for Subscale Experimental Research). The designed FTC law of the airplane is simulated for pitch angle command tracking under a false identification case.
Hydrostatic temperature calculations. [in synoptic meteorology
NASA Technical Reports Server (NTRS)
Raymond, William H.
1987-01-01
Comparisons are made between hydrostatically computed temperatures and ambient temperatures associated with nine different data sources, including analyses, forecasts and conventional observations. Five-day averages and the day-to-day variations in the root-mean-square temperature differences are presented. Several different numerical and interpolation procedures are examined. Error correction and a constrained optimum procedure that minimizes ambient minus calculated hydrostatic temperature differences are introduced. Systematic differences between ambient and hydrostatic temperatures are found to be associated with the sinoptic situation. When compared with ambient temperatures, hydrostatic temperatures at 500 mb tend to be too warm at or in front of a trough and too cold behind the trough. In the vertical direction, for the eight-level configuration tested, the average hydrostatic temperatures are too cold at low levels (850, 700 mb) and too warm at upper levels, (300, 250 mb).
Han, Peng; Niu, Chang-Ying; Lei, Chao-Liang; Cui, Jin-Jie; Desneux, Nicolas
2010-11-01
Transgenic Cry1Ac+CpTI cotton (CCRI41) is a promising cotton cultivar throughout China but side effects and especially sublethal effects of this transgenic cultivar on beneficial insects remain poorly studied. More specifically potential sublethal effects on behavioural traits of the honey bee Apis mellifera L. have not been formally assessed despite the importance of honey bees for pollination. The goal of our study was to assess potential effects of CCRI41 cotton pollen on visual and olfactory learning by honey bees. After a 7-day oral chronic exposure to honey mixed with either CCRI41 pollen, imidacloprid-treated conventional pollen (used as positive sublethal control) or conventional pollen (control), learning performance was evaluated by the classical proboscis extension reflex (PER) procedure as well as a T-tube maze test. The latter assay was designed as a new device to assess potential side effects of pesticides on visual associative learning of honey bees. These two procedures were complementary because the former focused on olfactory learning while the latter was involved in visual learning based on visual orientation ability. Oral exposure to CCRI41 pollen did not affect learning capacities of honey bees in both the T-tube maze and PER tests. However, exposure to imidacloprid resulted in reduced visual learning capacities in T-tube maze evaluation and decreased olfactory learning performances measured with PER. The implications of these results are discussed in terms of risks of transgenic CCRI41 cotton crops for honey bees.
Evaluation of the White Test for the Intraoperative Detection of Bile Leakage
Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-ad
2012-01-01
We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was compared between the conventional method and the White test. A bile leak was demonstrated in 8 patients (26.7%) by the conventional method and in 19 patients (63.3%) by the White test. In addition, the White test detected a significantly higher number of bile leakage sites compared with the conventional method (Wilcoxon signed-rank test; P < 0.001). The White test is better than the conventional test for the intraoperative detection of bile leakage. Based on our study, we recommend that surgeons investigating bile leakage sites during liver resections should use the White test instead of the conventional bile leakage test. PMID:22547901
Evaluation of the white test for the intraoperative detection of bile leakage.
Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-Ad
2012-01-01
We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was compared between the conventional method and the White test. A bile leak was demonstrated in 8 patients (26.7%) by the conventional method and in 19 patients (63.3%) by the White test. In addition, the White test detected a significantly higher number of bile leakage sites compared with the conventional method (Wilcoxon signed-rank test; P < 0.001). The White test is better than the conventional test for the intraoperative detection of bile leakage. Based on our study, we recommend that surgeons investigating bile leakage sites during liver resections should use the White test instead of the conventional bile leakage test.
A novel stereotactic frame for real PET-guided biopsies: A preclinical proof-of-concept.
Cortes-Rodicio, J; Sanchez-Merino, G; Garcia-Fidalgo, M A; Tobalina-Larrea, I
2017-09-01
To design, build and test a stereotactic device that allows PET image-guided biopsies to be performed. An initial prototype consisting of four main pieces, one of which contains radioactive markers to make it visible in the PET images, was built using a 3D printer. Once the device is mounted, a spherical coordinate system is built with the entrance needle point in the skin as the origin of coordinates. Two in-house software programs, namely getCoord.ijm, which obtains the spherical coordinates of the tumour tissue to be biopsied, and getNeedle.ijm, which virtualizes the inner needle tip once the puncture has taken place, were written. This prototype was tested on an FDG-doped phantom to characterize both the accuracy of the system and the procedure time. Up to 11 complete biopsy procedures were conducted. The mean total procedure time was less than 20min, which is less than the procedure time of conventional standard CT-guided biopsies. The overall accuracy of the system was found to be 5.0±1.3mm, which outperforms the criterion used in routine clinical practice when targeting tumours with a diameter of 10mm. A stereotactic frame to conduct real PET image-guided biopsies has been designed and built. A proof-of-concept was performed to characterize the system. The procedure time and accuracy of the system were found to meet the current needs of physicians performing biopsies. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Anderson, Dallas W.; Hsu, Tung M.; Halpern, Steven J.; Honaker, Arnold
1993-07-01
The ProClosureTM System (PCS) consists of a low power 1.32micrometers Nd:YAG laser coupled to a handheld disposable fiber optic device. The system has been designed to perform a wide range of tissue welding applications such as cosmetic skin closure,vascular surgery, and minimally invasive surgical procedures normally performed with sutures and staples. Utilizing a wavelength for tissue fusion that is least distracted by medium in the surgical field coupled with a computerized delivery system allows for a more precise application (+/- 5%) of laser energy to the tissue. The study design involved the micro-surgical anastomosis of twenty Sprague-Dawley rats (vas deferens) and twenty-one Sprague-Dawley rats (femoral arteries). Each rat is its own contralateral control. Laser repair time is approximately one-third that of conventional suturing. Postoperative dissection and burst strength testing was conducted at day 0, 1, 7, and 14. At each postoperative interval, the mean leak/burst strength for laser-assisted closure v. control, was markedly higher. The precise application of energy fluence resulting from ProClosure's computerized system yields an initial strength and a fluid static seal that is superior to conventional suture closure.
Applied high-speed imaging for the icing research program at NASA Lewis Research Center
NASA Technical Reports Server (NTRS)
Slater, Howard; Owens, Jay; Shin, Jaiwon
1992-01-01
The Icing Research Tunnel at NASA Lewis Research Center provides scientists a scaled, controlled environment to simulate natural icing events. The closed-loop, low speed, refrigerated wind tunnel offers the experimental capability to test for icing certification requirements, analytical model validation and calibration techniques, cloud physics instrumentation refinement, advanced ice protection systems, and rotorcraft icing methodology development. The test procedures for these objectives all require a high degree of visual documentation, both in real-time data acquisition and post-test image processing. Information is provided to scientific, technical, and industrial imaging specialists as well as to research personnel about the high-speed and conventional imaging systems will be on the recent ice protection technology program. Various imaging examples for some of the tests are presented. Additional imaging examples are available from the NASA Lewis Research Center's Photographic and Printing Branch.
Applied high-speed imaging for the icing research program at NASA Lewis Research Center
NASA Technical Reports Server (NTRS)
Slater, Howard; Owens, Jay; Shin, Jaiwon
1991-01-01
The Icing Research Tunnel at NASA Lewis Research Center provides scientists a scaled, controlled environment to simulate natural icing events. The closed-loop, low speed, refrigerated wind tunnel offers the experimental capability to test for icing certification requirements, analytical model validation and calibration techniques, cloud physics instrumentation refinement, advanced ice protection systems, and rotorcraft icing methodology development. The test procedures for these objectives all require a high degree of visual documentation, both in real-time data acquisition and post-test image processing. Information is provided to scientific, technical, and industrial imaging specialists as well as to research personnel about the high-speed and conventional imaging systems will be on the recent ice protection technology program. Various imaging examples for some of the tests are presented. Additional imaging examples are available from the NASA Lewis Research Center's Photographic and Printing Branch.
Rogers, C G; Tyson, J E; Kennedy, K A; Broyles, R S; Hickman, J F
1998-04-01
The objective of this study was to assess a modified consent procedure allowed under federal regulations and developed for studies, particularly clinical trials, that are judged by the Institutional Review Board to reduce or have no effect on patient risk. This was a randomized trial of a conventional consent procedure that required parental signature to give consent (opting in) after a comprehensive disclosure of the rights of participants in research versus a modified consent procedure that required parental signature to refuse consent (opting out) after specific disclosures appropriate when risk is not increased. Consent was sought for a trial of primary follow-up care for disadvantaged infants at high risk, a trial judged by our Institutional Review Board to increase access to care for both groups. A blinded assessor interviewed mothers within 24 hours of the consent decision. Among the 44 mothers interviewed, the modified consent group scored higher than the conventional consent group in recall and understanding of study purpose and methods (47% vs 30%; p < 0.02). Other comparisons provided no evidence that the modified consent procedure was less desirable. Virtually all mothers reported satisfaction. The modified approach may improve communication and facilitate studies judged by the Institutional Review Board to be risk-neutral or risk-reducing. Further evaluation of a modified consent procedure for such studies is warranted.
Assier, Haudrey; Valeyrie-Allanore, Laurence; Gener, Gwendeline; Verlinde Carvalh, Muriel; Chosidow, Olivier; Wolkenstein, Pierre
2017-11-01
Patch testing following a standardized protocol is reliable for identifying the culprit drug in cutaneous adverse drug reactions (CADRs). However, these patch tests (PTs) require pharmaceutical material and staff, which are not always easily available. To evaluate an extemporaneous PT method in CADRs. We retrospectively analysed data for all patients referred to our department between March 2009 and June 2013 for patch testing after a non-immediate CADR. The patients who supplied their own suspected drugs were tested both with extemporaneous PTs and with conventional PTs. Extemporaneous PTs involved a nurse crushing and diluting the drug in pet. in a ratio of approximately one-third to two-thirds. Standardized PTs were performed according to guidelines, with commercial drugs diluted to 30% or with active ingredients diluted to 10%. We analysed the data for the two PT methods in terms of the number of positive test reactions, drugs tested, and type of CADR for patients in whom the two PT methods were used. In total, 75 of 156 patients underwent the two PT procedures, including 91 double tests. Overall, 21 tests gave positive reactions with the two methods, and 69 other tests gave negative results with the two methods. Our series yielded results similar to those of published series concerning the types of CADR and the drugs responsible. Our results suggest that, for CADRs, if a patient supplies a suspected drug but if the pharmaceutical material and staff are not available for conventional PTs, extemporaneous PTs performed by the nurse with the commercial drug used by the patient can be useful and reliable. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Comparison of piezosurgery and conventional rotative instruments in direct sinus lifting.
Delilbasi, Cagri; Gurler, Gokhan
2013-12-01
The purpose of this study was to compare the intraoperative and postoperative effects of Piezosurgery and conventional rotative instruments in direct sinus lifting procedure. Twenty-three patients requiring direct sinus lifting were enrolled. The osteotomy and sinus membrane elevation were performed either with Piezosurgery tips or rotative diamond burs and manual membrane elevators. Time elapsed between bony window opening and completion of membrane elevation (duration), incidence of membrane perforation, visibility of the operation site, postoperative pain, swelling, sleeping, eating, phonetics, daily routine, and missed work as well as patient's expectation before and experience after the operation were evaluated. There was no significant difference between Piezosurgery and conventional groups regarding incidence of membrane perforation, duration, and operation site visibility as well as patient's expectation before and experience after the operation (P > 0.05). However, there were significantly more pain and swelling in the conventional group compared with the Piezosurgery group (P ≤ 0.05). Sinus lifting procedure performed with Piezosurgery causes less pain and swelling postoperatively compared with conventional technique. Patients' daily life activities and experience about the operation are not affected from the surgical technique.
Wu, John Z; Cutlip, Robert G; Welcome, Daniel; Dong, Ren G
2006-01-01
Knowledge of viscoelastic properties of soft tissues is essential for the finite element modelling of the stress/strain distributions in finger-pad during vibratory loading, which is important in exploring the mechanism of hand-arm vibration syndrome. In conventional procedures, skin and subcutaneous tissue have to be separated for testing the viscoelastic properties. In this study, a novel method has been proposed to simultaneously determine the viscoelastic properties of skin and subcutaneous tissue in uniaxial stress relaxation tests. A mathematical approach has been derived to obtain the creep and relaxation characteristics of skin and subcutaneous tissue using uniaxial stress relaxation data of skin/subcutaneous composite specimens. The micro-structures of collagen fiber networks in the soft tissue, which underline the tissue mechanical characteristics, will be intact in the proposed method. Therefore, the viscoelastic properties of soft tissues obtained using the proposed method would be more physiologically relevant than those obtained using the conventional method. The proposed approach has been utilized to measure the viscoelastic properties of soft tissues of pig. The relaxation curves of pig skin and subcutaneous tissue obtained in the current study agree well with those in literature. Using the proposed approach, reliable material properties of soft tissues can be obtained in a cost- and time-efficient manner, which simultaneously improves the physiological relevance.
NASA Technical Reports Server (NTRS)
Moore, N. R.; Ebbeler, D. H.; Newlin, L. E.; Sutharshana, S.; Creager, M.
1992-01-01
An improved methodology for quantitatively evaluating failure risk of spaceflight systems to assess flight readiness and identify risk control measures is presented. This methodology, called Probabilistic Failure Assessment (PFA), combines operating experience from tests and flights with engineering analysis to estimate failure risk. The PFA methodology is of particular value when information on which to base an assessment of failure risk, including test experience and knowledge of parameters used in engineering analyses of failure phenomena, is expensive or difficult to acquire. The PFA methodology is a prescribed statistical structure in which engineering analysis models that characterize failure phenomena are used conjointly with uncertainties about analysis parameters and/or modeling accuracy to estimate failure probability distributions for specific failure modes, These distributions can then be modified, by means of statistical procedures of the PFA methodology, to reflect any test or flight experience. Conventional engineering analysis models currently employed for design of failure prediction are used in this methodology. The PFA methodology is described and examples of its application are presented. Conventional approaches to failure risk evaluation for spaceflight systems are discussed, and the rationale for the approach taken in the PFA methodology is presented. The statistical methods, engineering models, and computer software used in fatigue failure mode applications are thoroughly documented.
NASA Technical Reports Server (NTRS)
Moore, N. R.; Ebbeler, D. H.; Newlin, L. E.; Sutharshana, S.; Creager, M.
1992-01-01
An improved methodology for quantitatively evaluating failure risk of spaceflight systems to assess flight readiness and identify risk control measures is presented. This methodology, called Probabilistic Failure Assessment (PFA), combines operating experience from tests and flights with engineering analysis to estimate failure risk. The PFA methodology is of particular value when information on which to base an assessment of failure risk, including test experience and knowledge of parameters used in engineering analyses of failure phenomena, is expensive or difficult to acquire. The PFA methodology is a prescribed statistical structure in which engineering analysis models that characterize failure phenomena are used conjointly with uncertainties about analysis parameters and/or modeling accuracy to estimate failure probability distributions for specific failure modes. These distributions can then be modified, by means of statistical procedures of the PFA methodology, to reflect any test or flight experience. Conventional engineering analysis models currently employed for design of failure prediction are used in this methodology. The PFA methodology is described and examples of its application are presented. Conventional approaches to failure risk evaluation for spaceflight systems are discussed, and the rationale for the approach taken in the PFA methodology is presented. The statistical methods, engineering models, and computer software used in fatigue failure mode applications are thoroughly documented.
Recommended Experimental Procedures for Evaluation of Abrupt Wing Stall Characteristics
NASA Technical Reports Server (NTRS)
Capone, F. J.; Hall, R. M.; Owens, D. B.; Lamar, J. E.; McMillin, S. N.
2003-01-01
This paper presents a review of the experimental program under the Abrupt Wing Stall (AWS) Program. Candidate figures of merit from conventional static tunnel tests are summarized and correlated with data obtained in unique free-to-roll tests. Where possible, free-to-roll results are also correlated with flight data. Based on extensive studies of static experimental figures of merit in the Abrupt Wing Stall Program for four different aircraft configurations, no one specific figure of merit consistently flagged a warning of potential lateral activity when actual activity was seen to occur in the free-to-roll experiments. However, these studies pointed out the importance of measuring and recording the root mean square signals of the force balance.
Adaptive laser conditioning of reflective thin film based on photo thermal lens probe
NASA Astrophysics Data System (ADS)
Liu, Zhichao; Zheng, Yi; Zhang, Qinghua; Pan, Feng; Wei, Yaowei; Wang, Jian; Xu, Qiao
2017-12-01
A novel laser conditioning (LC) concept that performs adaptive control of exposure fluence is proposed. As photo-thermal absorption effect can discover defects responsible for laser-induced damage of reflective thin film, in situ photo-thermal lens probe is introduced in conventional LC procedure to detect defects during raster-scanning. The absorptance signal is fed back to guide the adaptive control of exposure fluence. By this method, the damage risk accompanying with LC can be reduced to a rather low level. In order to test the performance of adaptive laser conditioning (ALC), an experimental setup has been built, and several film samples have been tested. The results show that ALC is effective at reducing laser damage risk.
22 CFR 94.6 - Procedures for children abducted to the United States.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Procedures for children abducted to the United... CHILD ABDUCTION § 94.6 Procedures for children abducted to the United States. The U.S. Central Authority... to all Hague Convention applications seeking the return of children wrongfully removed to or retained...
Hanedan, Muhammet Onur; Yuruk, Mehmet Ali; Parlar, Ali Ihsan; Ziyrek, Ugur; Arslan, Ali Kemal; Sayar, Ufuk; Mataraci, Ilker
2018-02-01
In elderly, high-risk surgical patients, sutureless aortic valve replacement (AVR) can often be an alternative to conventional AVR; shorter aortic cross-clamp and cardiopulmonary bypass times are the chief advantages. We compared the outcomes of sutureless AVR with those of conventional AVR in 70 elderly patients who underwent concomitant cardiac surgical procedures. We retrospectively analyzed the cases of 42 men and 28 women (mean age, 70.4 ± 10.3 yr; range, 34-93 yr) who underwent cardiac operations plus AVR with either a sutureless valve (group 1, n=38) or a conventional bioprosthetic or mechanical valve (group 2, n=32). Baseline patient characteristics were similar except for worse New York Heart Association functional status and the prevalence of diabetes mellitus in group 1. In group 1, the operative, cross-clamp, and cardiopulmonary bypass times were shorter (all P =0.001), postoperative drainage amounts were lower ( P =0.009), hospital stays were shorter ( P =0.004), and less red blood cell transfusion was needed ( P =0.037). Echocardiograms before patients' discharge from the hospital showed lower peak and mean aortic gradients in group 1 (mean transvalvular gradient, 8.4 ± 2.8 vs 12.2 ± 5.2 mmHg; P =0.012). We found that elderly, high-risk patients who underwent multiple cardiac surgical procedures and sutureless AVR had better hemodynamic outcomes and shorter ischemic times than did patients who underwent conventional AVR.
Evaluation and Analysis of F-16XL Wind Tunnel Data From Static and Dynamic Tests
NASA Technical Reports Server (NTRS)
Kim, Sungwan; Murphy, Patrick C.; Klein, Vladislav
2004-01-01
A series of wind tunnel tests were conducted in the NASA Langley Research Center as part of an ongoing effort to develop and test mathematical models for aircraft rigid-body aerodynamics in nonlinear unsteady flight regimes. Analysis of measurement accuracy, especially for nonlinear dynamic systems that may exhibit complicated behaviors, is an essential component of this ongoing effort. In this report, tools for harmonic analysis of dynamic data and assessing measurement accuracy are presented. A linear aerodynamic model is assumed that is appropriate for conventional forced-oscillation experiments, although more general models can be used with these tools. Application of the tools to experimental data is demonstrated and results indicate the levels of uncertainty in output measurements that can arise from experimental setup, calibration procedures, mechanical limitations, and input errors.
Improved Quality in Aerospace Testing Through the Modern Design of Experiments
NASA Technical Reports Server (NTRS)
DeLoach, R.
2000-01-01
This paper illustrates how, in the presence of systematic error, the quality of an experimental result can be influenced by the order in which the independent variables are set. It is suggested that in typical experimental circumstances in which systematic errors are significant, the common practice of organizing the set point order of independent variables to maximize data acquisition rate results in a test matrix that fails to produce the highest quality research result. With some care to match the volume of data required to satisfy inference error risk tolerances, it is possible to accept a lower rate of data acquisition and still produce results of higher technical quality (lower experimental error) with less cost and in less time than conventional test procedures, simply by optimizing the sequence in which independent variable levels are set.
Robotic bariatric surgery: A general review of the current status.
Jung, Minoa K; Hagen, Monika E; Buchs, Nicolas C; Buehler, Leo H; Morel, Philippe
2017-12-01
While conventional laparoscopy is the gold standard for almost all bariatric procedures, robotic assistance holds promise for facilitating complex surgeries and improving clinical outcomes. Since the report of the first robotic-assisted bariatric procedure in 1999, numerous publications, including those reporting comparative trials and meta-analyses across bariatric procedures with a focus on robotic assistance, can be found. This article reviews the current literature and portrays the perspectives of robotic bariatric surgery. While there are substantial reports on robotic bariatric surgery currently in publication, most studies suffer from low levels of evidence. As such, although robotics technology is without a doubt superior to conventional laparoscopy, the precise role of robotics in bariatric surgery is not yet clear. Copyright © 2017 John Wiley & Sons, Ltd.
ERIC Educational Resources Information Center
Joint Center for Political Studies, Washington, DC.
This guide was designed to assist black delegates attending the 1976 Democratic National Convention. The guide is divided into four main parts. The first part contains information on convention procedures, standing committees, and various aspects of black participation in politics. The second and third parts lists the names of alternates as well…
Descent advisor preliminary field test
NASA Technical Reports Server (NTRS)
Green, Steven M.; Vivona, Robert A.; Sanford, Beverly
1995-01-01
A field test of the Descent Advisor (DA) automation tool was conducted at the Denver Air Route Traffic Control Center in September 1994. DA is being developed to assist Center controllers in the efficient management and control of arrival traffic. DA generates advisories, based on trajectory predictions, to achieve accurate meter-fix arrival times in a fuel efficient manner while assisting the controller with the prediction and resolution of potential conflicts. The test objectives were to evaluate the accuracy of DA trajectory predictions for conventional- and flight-management-system-equipped jet transports, to identify significant sources of trajectory prediction error, and to investigate procedural and training issues (both air and ground) associated with DA operations. Various commercial aircraft (97 flights total) and a Boeing 737-100 research aircraft participated in the test. Preliminary results from the primary test set of 24 commercial flights indicate a mean DA arrival time prediction error of 2.4 sec late with a standard deviation of 13.1 sec. This paper describes the field test and presents preliminary results for the commercial flights.
Recent Improvements in Semi-Span Testing at the National Transonic Facility (Invited)
NASA Technical Reports Server (NTRS)
Gatlin, G. M.; Tomek, W. G.; Payne, F. M.; Griffiths, R. C.
2006-01-01
Three wind tunnel investigations of a commercial transport, high-lift, semi-span configuration have recently been conducted in the National Transonic Facility at the NASA Langley Research Center. Throughout the course of these investigations multiple improvements have been developed in the facility semi-span test capability. The primary purpose of the investigations was to assess Reynolds number scale effects on a modern commercial transport configuration up to full-scale flight test conditions (Reynolds numbers on the order of 27 million). The tests included longitudinal aerodynamic studies at subsonic takeoff and landing conditions across a range of Reynolds numbers from that available in conventional wind tunnels up to flight conditions. The purpose of this paper is to discuss lessons learned and improvements incorporated into the semi-span testing process. Topics addressed include enhanced thermal stabilization and moisture reduction procedures, assessments and improvements in model sealing techniques, compensation of model reference dimensions due to test temperature, significantly improved semi-span model access capability, and assessments of data repeatability.
Influence of mixing procedure on robustness of self-consolidating concrete.
DOT National Transportation Integrated Search
2014-08-01
Self-Consolidating Concrete is, in the fresh state, more sensitive to small variations in the constituent elements and the mixing : procedure compared to Conventional Vibrated Concrete. Several studies have been performed recently to identify robustn...
Buldur, Burak; Kapdan, Arife
The purpose of this study was to compare the antimicrobial efficacy of the EndoVac system and conventional needle irrigation to eliminate E faecalis in primary molar root canals. 60 extracted human primary second molar roots were instrumented up to an apical size .04/35 and randomly divided into two groups; Group 1: conventional needle (n=30) and Group 2: EndoVac (n=30), and four subgroups (two experimental subgroups; (a) 2.5% sodium hypochlorite (NaOCl) + ethylenediaminetetraacetic acid (EDTA) (n=20), (b) ozonated water (OW) + EDTA (n=20), and control groups (c) 5.25% NaOCl (n=10) and (d) saline (n=10). All roots were sterilized and then inoculated with E.faecalis. Before and after final irrigation procedures, root canals were sampled and the grown colony forming units (CFUs) were counted. Data were analyzed by Kruskall-Wallis and Mann-Whitney U tests using a 0.05 significance level. The EndoVac reduced more bacteria than the conventional needle did but it was not statistically significant (p>0.05). NaOCl alone or followed by EDTA totally eliminated bacteria. OW + EDTA showed higher reduction of bacteria but could not totally eliminate bacterias. In the context of bacterial elimination, the EndoVac was not significantly better than the conventional needle. Although, there were fewer CFU/mg when using EndoVac, there was not any statistically significant superiority to conventional needle irrigation. An OW+EDTA regimen showed antibacterial effect in the primary molar root canals but it was significantly less effective than NaOCl+EDTA.
Atrial Fibrillation Ablation Guided by a Novel Nonfluoroscopic Navigation System.
Ballesteros, Gabriel; Ramos, Pablo; Neglia, Renzo; Menéndez, Diego; García-Bolao, Ignacio
2017-09-01
Rhythmia is a new nonfluoroscopic navigation system that is able to create high-density electroanatomic maps. The aim of this study was to describe the acute outcomes of atrial fibrillation (AF) ablation guided by this system, to analyze the volume provided by its electroanatomic map, and to describe its ability to locate pulmonary vein (PV) reconnection gaps in redo procedures. This observational study included 62 patients who underwent AF ablation with Rhythmia compared with a retrospective cohort who underwent AF ablation with a conventional nonfluoroscopic navigation system (Ensite Velocity). The number of surface electrograms per map was significantly higher in Rhythmia procedures (12 125 ± 2826 vs 133 ± 21 with Velocity; P < .001), with no significant differences in the total procedure time. The Orion catheter was placed for mapping in 99.5% of PV (95.61% in the control group with a conventional circular mapping catheter; P = .04). There were no significant differences in the percentage of PV isolation between the 2 groups. In redo procedures, an ablation gap could be identified on the activation map in 67% of the reconnected PV (40% in the control group; P = .042). The measured left atrial volume was lower than that calculated by computed tomography (109.3 v 15.2 and 129.9 ± 13.2 mL, respectively; P < .001). There were no significant differences in the number of complications. The Rhythmia system is effective for AF ablation procedures, with procedure times and safety profiles similar to conventional nonfluoroscopic navigation systems. In redo procedures, it appears to be more effective in identifying reconnected PV conduction gaps. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Immunological strain specificity within type 1 poliovirus*
Gard, Sven
1960-01-01
The demonstration of immunological differences between poliovirus strains of any one type is a valuable procedure in epidemiological research as it may allow a virus strain to be identified as derived from or unrelated to a given possible source of infection. It is obviously of particular importance in connexion with live poliovirus vaccination campaigns. Both kinetic tests and conventional neutralization and complement-fixation techniques have been used to this end, the former involving a more complicated test procedure and the latter demanding greater nicety in the pre-standardization of reagents. The present paper reports on attempts to establish a simplified technique. Neutralization titres of sera obtained by immunization of guinea-pigs with three strains of type 1 poliovirus (including one isolated from a patient in the 1958-59 epidemic in Léopoldville described in the two preceding papers) indicated a degree of strain specificity sufficient to permit the design of a simple screening method for the purpose of a rough immunological classification. Preliminary observations on isolates from persons fed attenuated virus indicate that antigenic changes may occur in the course of multiplication of the virus in the human intestinal tract. PMID:13826481
Feature Vector Construction Method for IRIS Recognition
NASA Astrophysics Data System (ADS)
Odinokikh, G.; Fartukov, A.; Korobkin, M.; Yoo, J.
2017-05-01
One of the basic stages of iris recognition pipeline is iris feature vector construction procedure. The procedure represents the extraction of iris texture information relevant to its subsequent comparison. Thorough investigation of feature vectors obtained from iris showed that not all the vector elements are equally relevant. There are two characteristics which determine the vector element utility: fragility and discriminability. Conventional iris feature extraction methods consider the concept of fragility as the feature vector instability without respect to the nature of such instability appearance. This work separates sources of the instability into natural and encodinginduced which helps deeply investigate each source of instability independently. According to the separation concept, a novel approach of iris feature vector construction is proposed. The approach consists of two steps: iris feature extraction using Gabor filtering with optimal parameters and quantization with separated preliminary optimized fragility thresholds. The proposed method has been tested on two different datasets of iris images captured under changing environmental conditions. The testing results show that the proposed method surpasses all the methods considered as a prior art by recognition accuracy on both datasets.
An assembly-type master-slave catheter and guidewire driving system for vascular intervention.
Cha, Hyo-Jeong; Yi, Byung-Ju; Won, Jong Yun
2017-01-01
Current vascular intervention inevitably exposes a large amount of X-ray to both an operator and a patient during the procedure. The purpose of this study is to propose a new catheter driving system which assists the operator in aspects of less X-ray exposure and convenient user interface. For this, an assembly-type 4-degree-of-freedom master-slave system was designed and tested to verify the efficiency. First, current vascular intervention procedures are analyzed to develop a new robotic procedure that enables us to use conventional vascular intervention devices such as catheter and guidewire which are commercially available in the market. Some parts of the slave robot which contact the devices were designed to be easily assembled and dissembled from the main body of the slave robot for sterilization. A master robot is compactly designed to conduct insertion and rotational motion and is able to switch from the guidewire driving mode to the catheter driving mode or vice versa. A phantom resembling the human arteries was developed, and the master-slave robotic system is tested using the phantom. The contact force of the guidewire tip according to the shape of the arteries is measured and reflected to the user through the master robot during the phantom experiment. This system can drastically reduce radiation exposure by replacing human effort by a robotic system for high radiation exposure procedures. Also, benefits of the proposed robot system are low cost by employing currently available devices and easy human interface.
Comparative study between manual injection intraosseous anesthesia and conventional oral anesthesia
Ata-Ali, Javier; Oltra-Moscardó, María J.; Peñarrocha-Diago, María; Peñarrocha, Miguel
2012-01-01
Objective: To compare intraosseous anesthesia (IA) with the conventional oral anesthesia techniques. Materials and methods: A simple-blind, prospective clinical study was carried out. Each patient underwent two anesthetic techniques: conventional (local infiltration and locoregional anesthetic block) and intraosseous, for res-pective dental operations. In order to allow comparison of IA versus conventional anesthesia, the two operations were similar and affected the same two teeth in opposite quadrants. Results: A total of 200 oral anesthetic procedures were carried out in 100 patients. The mean patient age was 28.6±9.92 years. Fifty-five vestibular infiltrations and 45 mandibular blocks were performed. All patients were also subjected to IA. The type of intervention (conservative or endodontic) exerted no significant influence (p=0.58 and p=0.62, respectively). The latency period was 8.52±2.44 minutes for the conventional techniques and 0.89±0.73 minutes for IA – the difference being statistically significant (p<0.05). Regarding patient anesthesia sensation, the infiltrative techniques lasted a maximum of one hour, the inferior alveolar nerve blocks lasted between 1-3 hours, and IA lasted only 2.5 minutes – the differences being statistically significant (p≤0.0000, Φ=0.29). Anesthetic success was recorded in 89% of the conventional procedures and in 78% of the IA. Most patients preferred IA (61%) (p=0.0032). Conclusions: The two anesthetic procedures have been compared for latency, duration of anesthetic effect, anesthetic success rate and patient preference. Intraosseous anesthesia has been shown to be a technique to be taken into account when planning conservative and endodontic treatments. Key words: Anesthesia, intraosseous, oral anesthesia, Stabident®, infiltrative, mandibular block. PMID:22143700
Steinmetz, Michael P; Mroz, Thomas E; Krishnaney, Ajit; Modic, Michael
2009-12-01
In today's health-care environment, operational efficiency is intrinsic to balancing the need for increased productivity driven by rising costs and potentially decreasing reimbursement. Other operational factors kept constant, decreasing the time for a procedure can be viewed as one marker for increased efficiency. To prospectively evaluate the time and operating room efficiency differences between the two methods for intraoperative level localization. STYDY DESIGN: Prospective nonrandomized study. Prospective consecutive patients undergoing a single-level anterior cervical discectomy and fusion (ACDF) with plate and allograft. Time for performance and interpretation of intraoperative localization radiograph. This is a prospective nonrandomized study of patients treated consecutively with a single-level ACDF with allograft and plating. All the patients underwent a conventional approach to the cervical spine. After exposure, a spinal needle was placed in the exposed intervertebral disc and a radiography was performed. Either a conventional or a digital radiography was used in each case. Eighteen patients were enrolled in this study. Ten patients underwent localization with conventional radiography, whereas eight patients underwent localization with digital imaging. The mean time for conventional radiography was 823 seconds (standard deviation [SD], 159), and for digital, it was 100 seconds (SD, 34; p<.001). Current technology provides options for level localization. Digital imaging provides equally accurate information as conventional radiography in a significantly reduced amount of time. Image quality, ease or archival, and manipulation provided by digital radiography are superior to those by provided fluoroscopy. Keeping operational factors constant, decreasing the time for a procedure, and increasing the efficiency of the environment may be viewed as a surrogate for improving the cost basis for a procedure.
Virtual reality lead extraction as a method for training new physicians: a pilot study.
Maytin, Melanie; Daily, Thomas P; Carillo, Roger G
2015-03-01
It is estimated that the demand for transvenous lead extraction (TLE) has reached an annual extraction rate of nearly 24,000 patients worldwide. Despite technologic advances, TLE still has the potential for significant morbidity and mortality. Complication rates with TLE directly parallel operator experience. However, obtaining adequate training during and postfellowship can be difficult. Given the potential for catastrophic complications and the steep learning curve (up to 300 cases) associated with this procedure, we sought to validate a virtual reality (VR) lead extraction simulator as an innovative training and evaluation tool for physicians new to TLE. We randomized eight electrophysiology fellows to VR simulator versus conventional training. We compared procedural skill competency between the groups using simulator competency, tactile measurements, markers of proficiency and attitudes, and cognitive abilities battery. Practical skills and simulator complications differed significantly between the VR simulator and conventional training groups. The VR simulator group executed patient preparation and procedure performance better than the conventional group (P < 0.01). All four fellows randomized to conventional training experienced a simulator complication (two superior vena cava [SVC] tears, three right ventricle [RV] avulsions) versus one fellow in the VR simulator group (one SVC tear) (P = 0.02). Tactile measurements revealed a trend toward excess pushing versus pulling forces among the conventionally trained group. The time for lead removal was also significantly higher in the conventional training group (12.46 minutes vs 5.54 minutes, P = 0.02). There was no significant difference in baseline or posttraining cognitive ability. We contend that the implementation of alternative training tools such as a VR simulation model will improve physician training and allow for an innovative pathway to assess the achievement of competency. ©2014 Wiley Periodicals, Inc.
Yap, Elaine
2017-01-01
In diagnosing peripheral pulmonary lesions (PPL), radial endobronchial ultrasound (R‐EBUS) is emerging as a safer method in comparison to CT‐guided biopsy. Despite the better safety profile, the yield of R‐EBUS remains lower (73%) than CT‐guided biopsy (90%) due to the smaller size of samples. We adopted a hybrid method by adding cryobiopsy via the R‐EBUS Guide Sheath (GS) to produce larger, non‐crushed samples to improve diagnostic capability and enhance molecular testing. We report six prospective patients who underwent this procedure in our institution. R‐EBUS samples were obtained via conventional sampling methods (needle aspiration, forceps biopsy, and cytology brush), followed by a cryobiopsy. An endobronchial blocker was placed near the planned area of biopsy in advance and inflated post‐biopsy to minimize the risk of bleeding in all patients. A chest X‐ray was performed 1 h post‐procedure. All the PPLs were visualized with R‐EBUS. The mean diameter of cryobiopsy samples was twice the size of forceps biopsy samples. In four patients, cryobiopsy samples were superior in size and the number of malignant cells per high power filed and was the preferred sample selected for mutation analysis and molecular testing. There was no pneumothorax or significant bleeding to report. Cryobiopsy samples were consistently larger and were the preferred samples for molecular testing, with an increase in the diagnostic yield and reduction in the need for repeat procedures, without hindering the marked safety profile of R‐EBUS. Using an endobronchial blocker improves the safety of this procedure. PMID:29321931
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hakime, Antoine, E-mail: thakime@yahoo.com; Yevich, Steven; Tselikas, Lambros
PurposeTo assess whether fusion imaging-guided percutaneous microwave ablation (MWA) can improve visibility and targeting of liver metastasis that were deemed inconspicuous on ultrasound (US).Materials and MethodsMWA of liver metastasis not judged conspicuous enough on US was performed under CT/US fusion imaging guidance. The conspicuity before and after the fusion imaging was graded on a five-point scale, and significance was assessed by Wilcoxon test. Technical success, procedure time, and procedure-related complications were evaluated.ResultsA total of 35 patients with 40 liver metastases (mean size 1.3 ± 0.4 cm) were enrolled. Image fusion improved conspicuity sufficiently to allow fusion-targeted MWA in 33 patients. The time requiredmore » for image fusion processing and tumors’ identification averaged 10 ± 2.1 min (range 5–14). Initial conspicuity on US by inclusion criteria was 1.2 ± 0.4 (range 0–2), while conspicuity after localization on fusion imaging was 3.5 ± 1 (range 1–5, p < 0.001). Technical success rate was 83% (33/40) in intention-to-treat analysis and 100% in analysis of treated tumors. There were no major procedure-related complications.ConclusionsFusion imaging broadens the scope of US-guided MWA to metastasis lacking adequate conspicuity on conventional US. Fusion imaging is an effective tool to increase the conspicuity of liver metastases that were initially deemed non visualizable on conventional US imaging.« less
Fang, Tuan-Jen; Li, Hsueh-Yu; Liao, Chun-Ta; Chiang, Hui-Chen; Chen, I-How
2015-07-01
Narrow band imaging (NBI)-guided flexible laryngoscopy tissue sampling for laryngopharyngeal lesions is a novel technique. Patients underwent the procedure in an office-based setting without being sedated, which is different from the conventional technique performed using direct laryngoscopy. Although the feasibility and effects of this procedure were established, its financial impact on the institution and Taiwanese National Health Insurance program was not determined. This is a retrospective case-control study. From May 2010 to April 2011, 20 consecutive patients who underwent NBI flexible laryngoscopy tissue sampling were recruited. During the same period, another 20 age-, sex-, and lesion-matched cases were enrolled in the control group. The courses for procedures and financial status were analyzed and compared between groups. Office-based NBI flexible laryngoscopy tissue sampling procedure took 27 minutes to be completed, while 191 minutes were required for the conventional technique. Average reimbursement for each case was New Taiwan Dollar (NT$)1264 for patients undergoing office-based NBI flexible laryngoscopy tissue sampling, while NT$10,913 for those undergoing conventional direct laryngoscopy in the operation room (p < 0.001). The institution suffered a loss of at least NT$690 when performing NBI flexible laryngoscopy tissue sampling. Office-based NBI flexible laryngoscopy tissue sampling is a cost-saving procedure for patients and the Taiwanese National Health Insurance program. It also saves the procedure time. However, the net financial loss for the institution and physician would limit its popularization unless reimbursement patterns are changed. Copyright © 2013. Published by Elsevier B.V.
Sabur, Huri; Baykara, Mehmet; Can, Basak
2016-01-01
Purpose: To compare the results of conventional 1064 nm neodymium-doped yttrium-aluminum garnet laser goniopuncture (Nd:YAG-GP) and selective 532 nm Nd:YAG laser (selective laser trabeculoplasty [SLT]) gonioreconditioning (GR) on trabeculo-Descemet's membrane in eyes resistant to viscocanalostomy surgery. Methods: Thirty-eight eyes of 35 patients who underwent laser procedure after successful viscocanalostomy surgery were included in the study. When postoperative intraocular pressure (IOP) was above the individual target, the eyes were scheduled for laser procedure. Nineteen eyes underwent 532 nm SLT-GR (Group 1), and the remaining 19 eyes underwent conventional 1064 nm Nd:YAG-GP (Group 2). IOPs before and after laser (1 week, 1 month, 3 months, 6 months, 1 year, and last visit), follow-up periods, number of glaucoma medications, and complications were recorded for both groups. Results: Mean times from surgery to laser procedures were 17.3 ± 9.6 months in Group 1 and 13.0 ± 11.4 months in Group 2. Mean IOPs before laser procedures were 21.2 ± 1.7 mmHg in Group 1 and 22.8 ± 1.9 mmHg in Group 2 (P = 0.454). Postlaser IOP measurements of Group 1 were 12.1 ± 3.4 mmHg and 13.8 ± 1.7 mmHg in the 1st week and last visit, respectively; in Group 2, these measurements were 13.6 ± 3.7 mmHg and 14.9 ± 4.8 mmHg, respectively. There were statistically significant differences (P < 0.001) in IOP reduction at all visits in both groups; the results of the two groups were similar (P > 0.05). Mean follow-up was 16.6 ± 6.4 months after SLT-GR and 18.9 ± 11.2 months after Nd:YAG-GP. Conclusions: While conventional Nd:YAG-GP and SLT-GR, a novel procedure, are both effective choices in eyes resistant to viscocanalostomy, there are fewer complications with SLT-GR. SLT-GR can be an alternative to conventional Nd:YAG-GP. PMID:27688277
Weber, Uwe; Constantinescu, Mihai A; Woermann, Ulrich; Schmitz, Felix; Schnabel, Kai
2016-01-01
Various different learning methods are available for planning tuition regarding the introduction to surgical hand disinfection. These learning methods should help to organise and deal with this topic. The use of a video film is an alternative to conventional tuition due to the real presentation possibilities of practical demonstration. This study examines by way of comparison which form of communication is more effective for learning and applying surgical hand disinfection for medical students in their first year of studies: video-based instruction or conventional tuition. A total of 50 first-year medical students were randomly allocated either to the "Conventional Instruction" (CI) study group or to the "Video-based Instruction" (VI) study group. The conventional instruction was carried out by an experienced nurse preceptor/nurse educator for the operating theatre who taught the preparatory measures and the actual procedure in a two-minute lesson. The second group watched a two-minute video sequence with identical content. Afterwards, both groups demonstrated practically the knowledge they had acquired at an individual practical test station. The quality (a) of the preparation and (b) of the procedure as well as (c) the quality of the results was assessed by 6 blind experts using a check list. The acceptability of the respective teaching method was also asked about using a questionnaire. The group performance did not differ either in the preparation (t=-78, p<0.44) or in the quality (t=-99, p<0.34). With respect to performance, it was possible to demonstrate a strong treatment effect. In the practical (t=-3.33, p<0.002, d=0.943) and in the total score (t=-2.65, p<0.011, d=0.751), the group with video-based instruction achieved a significantly better result. In response to the question as to which of the two learning methods they would prefer, the significant majority (60.4%) of students stated video instruction. In this study, the use of the video-based instruction emerged as the more effective teaching method for learning surgical hand disinfection for medical students and is preferable to conventional instruction. The video instruction is associated with a higher learning effectiveness, efficiency and acceptability.
NASA Technical Reports Server (NTRS)
Atli, K. C.; Karaman, I.; Noebe, R. D.; Maier, H. J.
2010-01-01
We compare the effectiveness of a conventional thermomechanical training procedure and severe plastic deformation via equal channel angular extrusion to achieve improved functional stability in a Ti50.5Ni24.5Pd25 high-temperature shape memory alloy. Thermomechanical testing indicates that both methods result in enhanced shape memory characteristics, such as reduced irrecoverable strain and thermal hysteresis. The mechanisms responsible for the improvements are discussed in light of microstructural findings from transmission electron microscopy.
Dry coupling for whole-body small-animal photoacoustic computed tomography
NASA Astrophysics Data System (ADS)
Yeh, Chenghung; Li, Lei; Zhu, Liren; Xia, Jun; Li, Chiye; Chen, Wanyi; Garcia-Uribe, Alejandro; Maslov, Konstantin I.; Wang, Lihong V.
2017-04-01
We have enhanced photoacoustic computed tomography with dry acoustic coupling that eliminates water immersion anxiety and wrinkling of the animal and facilitates incorporating complementary modalities and procedures. The dry acoustic coupler is made of a tubular elastic membrane enclosed by a closed transparent water tank. The tubular membrane ensures water-free contact with the animal, and the closed water tank allows pressurization for animal stabilization. The dry coupler was tested using a whole-body small-animal ring-shaped photoacoustic computed tomography system. Dry coupling was found to provide image quality comparable to that of conventional water coupling.
Code of Federal Regulations, 2013 CFR
2013-04-01
... is used for the first time for transport under Customs seal. The TIR Convention, 1975, generally... that country is a contracting party to the Convention, may approve a series of road vehicles or containers presented for design type approval. The procedures for applying for certification are contained in...
Code of Federal Regulations, 2014 CFR
2014-04-01
... is used for the first time for transport under Customs seal. The TIR Convention, 1975, generally... that country is a contracting party to the Convention, may approve a series of road vehicles or containers presented for design type approval. The procedures for applying for certification are contained in...
Code of Federal Regulations, 2010 CFR
2010-04-01
... is used for the first time for transport under Customs seal. The TIR Convention, 1975, generally... that country is a contracting party to the Convention, may approve a series of road vehicles or containers presented for design type approval. The procedures for applying for certification are contained in...
Code of Federal Regulations, 2011 CFR
2011-04-01
... is used for the first time for transport under Customs seal. The TIR Convention, 1975, generally... that country is a contracting party to the Convention, may approve a series of road vehicles or containers presented for design type approval. The procedures for applying for certification are contained in...
Shahverdi, Abdolhossein; Movahedin, Mansoureh; Rezazadeh Valojerdi, Mojtaba; Kazemi Ashtiani, Saeid
2007-10-01
The purpose of this study was to evaluate the efficiency of intracytoplasmic sperm injection (ICSI) and Piezo-assisted sperm injection after pretreatment with calcium ionophore (CaI) on the mouse embryo development. In this study, the conventional ICSI and Piezo-ICSI procedures were used. The efficacy of the methods was examined after mouse matured oocytes were fertilized with or without CaI-treated sperms. Piezo-ICSI demonstrated significantly more favorable results, with a fertilization rate of 64% (conventional ICSI: 42%, P<0.001) and a cleavage rate of 73% (conventional ICSI: 58%, P<0.05). When the Piezo-ICSI procedure was performed with CaI-pretreated sperms, the cleavage rate significantly increased (92% vs. 73%, P<0.05). However, the fertilization rate did not change significantly (64% vs. 56%). The Piezo-ICSI accompanies with CaI-treated sperms is more efficient than the conventional ICSI method for fertilizing and thus obtaining more mouse embryos.
Lee, S H; Lee, N Y
2013-06-01
Pain control, which is necessary during most dental procedures, is administered by injecting a local anaesthetic. Because the injection itself can be painful, the procedure via which pain is reduced warrants continued investigation. Only a few studies regarding the reaction of children to dental needle insertion without the use of topical anaesthetics have been reported. This study was conducted to evaluate the efficacy of the local anaesthetic procedure without topical application as compared to the conventional insertion technique for alleviating pain in children receiving local anaesthesia injections. For the alternative injection procedure, the dentist quickly and gently pulled or pushed the clean and dried loose tissue at the injection site over the tip of the needle to a depth of 1 to 1.5 mm. When the end of the bevel of the needle tip entered the tissue, a few drops of solution were released, after which the needle was advanced to its proper and intended depth to continue anaesthetic release. There was a significant difference regarding the pain response between the alternative insertion technique (less painful) and the conventional one according to Sound, Eye, and Motor (SEM) scale ratings (P < 0.000). No significant difference was observed in the response between the maxilla and mandible, nor between boys and girls, between the conventional and alternative techniques. This alternative technique can reduce discomfort in paediatric dental patients and allow the clinician to administer a superficial local anaesthesia injection before the needle is advanced into deeper tissue. This technique is simple, quick, devoid of additional costs, and potentially more effective than the conventional needle insertion method.
Development of a digital impression procedure using photogrammetry for complete denture fabrication.
Matsuda, Takashi; Goto, Takaharu; Kurahashi, Kosuke; Kashiwabara, Toshiya; Ichikawa, Tetsuo
We developed an innovative procedure for digitizing maxillary edentulous residual ridges with a photogrammetric system capable of estimating three-dimensional (3D) digital forms from multiple two-dimensional (2D) digital images. The aim of this study was to validate the effectiveness of the photogrammetric system. Impressions of the maxillary residual ridges of five edentulous patients were taken with four kinds of procedures: three conventional impression procedures and the photogrammetric system. Plaster models were fabricated from conventional impressions and digitized with a 3D scanner. Two 3D forms out of four forms were superimposed with 3D inspection software, and differences were evaluated using a least squares best fit algorithm. The in vitro experiment suggested that better imaging conditions were in the horizontal range of ± 15 degrees and at a vertical angle of 45 degrees. The mean difference between the photogrammetric image (Form A) and the image taken from conventional preliminarily impression (Form C) was 0.52 ± 0.22 mm. The mean difference between the image taken of final impression through a special tray (Form B) and Form C was 0.26 ± 0.06 mm. The mean difference between the image taken from conventional final impression (Form D) and Form C was 0.25 ± 0.07 mm. The difference between Forms A and C was significantly larger than the differences between Forms B and C and between Forms D and C. The results of this study suggest that obtaining digital impressions of edentulous residual ridges using a photogrammetric system is feasible and available for clinical use.
DOT National Transportation Integrated Search
1966-04-01
A semiautomated technique is described for the estimation of total catecholamines in plasma by the trihydroxyindole procedure. The method utilizes conventional alumina-column chromatography for isolation of the amines. Catecholamine oxidation, tautom...
Results obtained with a low cost software-based audiometer for hearing screening.
Ferrari, Deborah Viviane; Lopez, Esteban Alejandro; Lopes, Andrea Cintra; Aiello, Camila Piccini; Jokura, Pricila Reis
2013-07-01
The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening. To evaluate the TS audiometer for conducting audiometric screening. A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated. For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively. The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening.
Lee, Hyoung Shin; Lee, Dongwon; Koo, Yong Cheol; Shin, Hyang Ae; Koh, Yoon Woo; Choi, Eun Chang
2013-03-01
In this study, the authors introduce and evaluate the feasibility of endoscopic resection using the retroauricular approach for various benign lesions of the upper neck. A retrospective comparative analysis was performed on the clinical outcomes of patients who underwent surgery for upper neck masses as endoscopic resection using the retroauricular approach or conventional transcervical resection at the authors' center from January 2010 through August 2011. The primary outcome was the cosmetic satisfaction of the patients in each group. In addition, the feasibility of the procedure was evaluated by comparing the operation time; hospital stay; amount and duration of drainage; complications such as marginal mandibular nerve, lingual, or hypoglossal nerve palsy; paresthesia of the ear lobe; and wound problems such as hematoma and skin necrosis. Statistical analysis was performed by independent-samples t test and the Fisher exact test, and a P value less than .05 was considered statistically significant. Thirty-six patients underwent endoscopic resection (endo group; 15 men, 21 women; mean age, 38.8 ± 15.0 years) and 40 patients underwent conventional transcervical resection (conventional group; 18 men, 22 women; mean age, 45.1 ± 14.1 years). The operating time in the endo group was longer than in the conventional group (P = .003). No significant difference was observed in the overall perioperative complications between the 2 groups. Cosmetic satisfaction evaluated with a graded scale showed much better results in the endo group (P < .001). Endoscopic resection using the retroauricular approach is feasible for various benign upper neck masses when conducted by an experienced endoscopic surgeon, with excellent cosmetic results. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Leadless Pacing: Current State and Future Direction.
Merkel, Matthias; Grotherr, Philipp; Radzewitz, Andrea; Schmitt, Claus
2017-12-01
Leadless pacing is now an established alternative to conventional pacing with subcutaneous pocket and transvenous lead for patients with class I or II single-chamber pacing indication. Available 12-month follow-up data shows a 48% fewer major complication rate in patients with Micra™ compared to a historical control group in a nonrandomized study [1]. There is one system with Food and Drug Administration (FDA) approval and two with the Communauté Européenne (CE) mark. The OPS code for the implantation is 8-83d.3 and the procedure has recently been rated as a "new Examination and Treatment Method (NUB)" in the German DRG system, meaning adequate reimbursement is negotiable with health insurance providers. The systems offer similar generator longevity and programming possibilities as conventional pacemaker systems, including rate response, remote monitoring, and MRI safety. The biggest downsides to date are limitations to single-chamber stimulation, lack of long-time data, and concerns of handling of the system at the end of its life span. However, implant procedure complication rates and procedure times do not exceed conventional pacemaker operations, and proper training and patient selection is provided.
Indocyanine green videoangiography methodological variations: review.
Simal-Julián, Juan A; Miranda-Lloret, Pablo; Evangelista-Zamora, Rocio; Sanromán-Álvarez, Pablo; Pérez de San Román, Laila; Pérez-Borredá, Pedro; Beltrán-Giner, Andrés; Botella-Asunción, Carlos
2015-01-01
Indocyanine green videoangiography (ICGVA) procedures have become widespread within the spectrum of microsurgical techniques for neurovascular pathologies. We have conducted a review to identify and assess the impact of all of the methodological variations of conventional ICGVA applied in the field of neurovascular pathology that have been published to date in the English literature. A total of 18 studies were included in this review, identifying four primary methodological variants compared to conventional ICGVA: techniques based on the transient occlusion, intra-arterial ICG administration via catheters, use of endoscope system with a filter to collect florescence of ICG, and quantitative fluorescence analysis. These variants offer some possibilities for resolving the limitations of the conventional technique (first, the vascular structure to be analyzed must be exposed and second, vascular filling with ICG follows an additive pattern) and allow qualitatively superior information to be obtained during surgery. Advantages and disadvantages of each procedure are discussed. More case studies with a greater number of patients are needed to compare the different procedures with their gold standard, in order to establish these results consistently.
Direct manipulation of physiological arousal in induced anxiety therapy - biofeedback approach.
Sappington, A A
1977-10-01
This study investigated the role of physiological arousal in the affect induction phase of Induced Anxiety therapy by using biofeedback to facilitate arousal. Twenty-one college students who were suffering from free-floating anxiety were assigned randomly to one of three groups: (1) a no-treatment control group simply completed the measures before and after therapy; (2) a conventional Induced Anxiety group went through five standard Induced Anxiety sessions; and (3) biofeedback Induced Anxiety group went through a similar procedure except that biofeedback was used in the affect induction phase to facilitate heart rate increase. It was found that the biofeedback procedure did result in a greater heart rate increase during the affect induction phase arousal than did the conventional procedure (.01 level of significance), but did not facilitate subjective emotional arousal. Biofeedback Induced Anxiety resulted in a greater reduction of trait anxiety as measured by the Multiple Affect Adjective Check List than did the no-treatment group or the conventonal Induced Anxiety group. The conventional Induced Anxiety group did not differ significantly from the no-treatment control group.
Han, Jubong; Lee, K B; Lee, Jong-Man; Park, Tae Soon; Oh, J S; Oh, Pil-Jei
2016-03-01
We discuss a new method to incorporate Type B uncertainty into least-squares procedures. The new method is based on an extension of the likelihood function from which a conventional least-squares function is derived. The extended likelihood function is the product of the original likelihood function with additional PDFs (Probability Density Functions) that characterize the Type B uncertainties. The PDFs are considered to describe one's incomplete knowledge on correction factors being called nuisance parameters. We use the extended likelihood function to make point and interval estimations of parameters in the basically same way as the least-squares function used in the conventional least-squares method is derived. Since the nuisance parameters are not of interest and should be prevented from appearing in the final result, we eliminate such nuisance parameters by using the profile likelihood. As an example, we present a case study for a linear regression analysis with a common component of Type B uncertainty. In this example we compare the analysis results obtained from using our procedure with those from conventional methods. Copyright © 2015. Published by Elsevier Ltd.
Yang, Yu-Chiao; Wei, Ming-Chi
2018-06-30
This study compared the use of ultrasound-assisted supercritical CO 2 (USC-CO 2 ) extraction to obtain apigenin-rich extracts from Scutellaria barbata D. Don with that of conventional supercritical CO 2 (SC-CO 2 ) extraction and heat-reflux extraction (HRE), conducted in parallel. This green procedure yielded 20.1% and 31.6% more apigenin than conventional SC-CO 2 extraction and HRE, respectively. Moreover, the extraction time required by the USC-CO 2 procedure, which used milder conditions, was approximately 1.9 times and 2.4 times shorter than that required by conventional SC-CO 2 extraction and HRE, respectively. Furthermore, the theoretical solubility of apigenin in the supercritical fluid system was obtained from the USC-CO 2 dynamic extraction curves and was in good agreement with the calculated values for the three empirical density-based models. The second-order kinetics model was further applied to evaluate the kinetics of USC-CO 2 extraction. The results demonstrated that the selected model allowed the evaluation of the extraction rate and extent of USC-CO 2 extraction. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ferreira, Mayra Soares; Mangussi-Gomes, João; Ximendes, Roberta; Evangelista, Anne Rosso; Miranda, Eloá Lumi; Garcia, Leonardo Bomediano; Stamm, Aldo C
2018-01-01
Pharyngeal tonsil hyperplasia is the most frequent cause of nasal obstruction and chronic mouth breathing during childhood. Adenoidectomy is the procedure of choice for the resolution of these symptoms. It is not yet known, however, whether the conventional technique ("blind curettage") has been surpassed by more modern adenoidectomy techniques (video-assisted, with the aid of instruments). This study aimed to compare the conventional adenoidectomy technique with two other emerging techniques, performed in a reference otorhinolaryngology center. This is a prospective and observational study of 33 children submitted to adenoidectomy using 3 different techniques that were followed up for a period of 3 months after surgery. The patients were divided into 3 different groups, according to the adenoidectomy technique: Group A (conventional technique - "blind curettage"); Group B (video-assisted adenoidectomy with microdebrider); Group C (video-assisted adenoidectomy with radiofrequency - Coblation ® ). The surgical time of each procedure was measured, being considered from the moment of insertion of the mouth gag until complete hemostasis was achieved. The questionnaire for quality of life OSA-18 was applied to all caregivers on the day of the surgery and 30-90 days after the procedure. Postoperative complications were also analyzed. For the entire patient sample, there was an improvement in quality of life after the surgery (p < 0.05). When analyzing the evolution of OSA-18 index, all groups showed statistically significant improvement, for all assessed domains. There were no statistically significant differences between the 3 techniques assessed for quality of life improvement after the surgery (p > 0.05). Regarding the duration of the procedure, the conventional technique showed the shortest surgical time when compared to the others (p < 0.05). No postoperative complications were noted, for any patient. The adenoidectomy resulted in improvement of quality of life, and there were no major postoperative complications, for all operated children, regardless of the technique used. The conventional technique was faster when compared to the more modern adenoidectomy techniques. Copyright © 2017 Elsevier B.V. All rights reserved.
Utility of Modified Ultrafast Papanicolaou Stain in Cytological Diagnosis
Arakeri, Surekha Ulhas
2017-01-01
Introduction Need for minimal turnaround time for assessing Fine Needle Aspiration Cytology (FNAC) has encouraged innovations in staining techniques that require lesser staining time with unequivocal cell morphology. The standard protocol for conventional Papanicolaou (PAP) stain requires about 40 minutes. To overcome this, Ultrafast Papanicolaou (UFP) stain was introduced which reduces staining time to 90 seconds and also enhances the quality. However, reagents required for this were not easily available hence, Modified Ultrafast Papanicolaou (MUFP) stain was introduced subsequently. Aim To assess the efficacy of MUFP staining by comparing the quality of MUFP stain with conventional PAP stain. Materials and Methods FNAC procedure was performed by using 10 ml disposable syringe and 22-23 G needle. Total 131 FNAC cases were studied which were lymph node (30), thyroid (38), breast (22), skin and soft tissue (24), salivary gland (11) and visceral organs (6). Two smears were prepared and stained by MUFP and conventional PAP stain. Scores were given on four parameters: background of smears, overall staining pattern, cell morphology and nuclear staining. Quality Index (QI) was calculated from ratio of total score achieved to maximum score possible. Statistical analysis using chi square test was applied to each of the four parameters before obtaining the QI in both stains. Students t-test was applied to evaluate the efficacy of MUFP in comparison with conventional PAP stain. Results The QI of MUFP for thyroid, breast, lymph node, skin and soft tissue, salivary gland and visceral organs was 0.89, 0.85, 0.89, 0.83, 0.92, and 0.78 respectively. Compared to conventional PAP stain QI of MUFP smears was better in all except visceral organ cases and was statistically significant. MUFP showed clear red blood cell background, transparent cytoplasm and crisp nuclear features. Conclusion MUFP is fast, reliable and can be done with locally available reagents with unequivocal morphology which is the need of the hour for a cytopathology set-up. PMID:28511391
Utility of Modified Ultrafast Papanicolaou Stain in Cytological Diagnosis.
Sinkar, Prachi; Arakeri, Surekha Ulhas
2017-03-01
Need for minimal turnaround time for assessing Fine Needle Aspiration Cytology (FNAC) has encouraged innovations in staining techniques that require lesser staining time with unequivocal cell morphology. The standard protocol for conventional Papanicolaou (PAP) stain requires about 40 minutes. To overcome this, Ultrafast Papanicolaou (UFP) stain was introduced which reduces staining time to 90 seconds and also enhances the quality. However, reagents required for this were not easily available hence, Modified Ultrafast Papanicolaou (MUFP) stain was introduced subsequently. To assess the efficacy of MUFP staining by comparing the quality of MUFP stain with conventional PAP stain. FNAC procedure was performed by using 10 ml disposable syringe and 22-23 G needle. Total 131 FNAC cases were studied which were lymph node (30), thyroid (38), breast (22), skin and soft tissue (24), salivary gland (11) and visceral organs (6). Two smears were prepared and stained by MUFP and conventional PAP stain. Scores were given on four parameters: background of smears, overall staining pattern, cell morphology and nuclear staining. Quality Index (QI) was calculated from ratio of total score achieved to maximum score possible. Statistical analysis using chi square test was applied to each of the four parameters before obtaining the QI in both stains. Students t-test was applied to evaluate the efficacy of MUFP in comparison with conventional PAP stain. The QI of MUFP for thyroid, breast, lymph node, skin and soft tissue, salivary gland and visceral organs was 0.89, 0.85, 0.89, 0.83, 0.92, and 0.78 respectively. Compared to conventional PAP stain QI of MUFP smears was better in all except visceral organ cases and was statistically significant. MUFP showed clear red blood cell background, transparent cytoplasm and crisp nuclear features. MUFP is fast, reliable and can be done with locally available reagents with unequivocal morphology which is the need of the hour for a cytopathology set-up.
Wang, Henry E; Donnelly, John P; Barton, Dustin; Jarvis, Jeffrey L
2018-05-01
Although often the focus of quality improvement efforts, emergency medical services (EMS) advanced airway management performance has few national comparisons, nor are there many assessments with benchmarks accounting for differences in agency volume or patient mix. We seek to assess variations in advanced airway management and conventional intubation performance in a national cohort of EMS agencies. We used EMS data from ESO Solutions, a national EMS electronic health record system. We identified EMS emergency responses with attempted advanced airway management (conventional intubation, rapid sequence intubation, sedation-assisted intubation, supraglottic airway insertion, and cricothyroidotomy). We also separately examined cases with initial conventional intubation. We determined EMS agency risk-standardized advanced airway management and initial conventional intubation success rates by using mixed-effects regression models, fitting agency as a random intercept, adjusting for patient age, sex, race, cardiac arrest, or trauma status, and use of rapid sequence or sedation-assisted intubation, and accounting for reliability variations from EMS agency airway volume. We assessed changes in agency advanced airway management and initial conventional intubation performance rank after risk and reliability adjustment. We also identified high and low performers (reliability-adjusted and risk-standardized success confidence intervals falling outside the mean). During 2011 to 2015, 550 EMS agencies performed 57,209 advanced airway management procedures. Among 401 EMS agencies with greater than or equal to 10 advanced airway management procedures, there were a total of 56,636 procedures. Median reliability-adjusted and risk-standardized EMS agency advanced airway management success was 92.9% (interquartile range 90.1% to 94.8%; minimum 58.2%; maximum 99.0%). There were 56 advanced airway management low-performing and 38 high-performing EMS agencies. Among 342 agencies with greater than or equal to 10 initial conventional intubations, there were a total of 37,360 initial conventional intubations. Median reliability-adjusted and risk-standardized EMS agency initial conventional intubation success was 77.3% (interquartile range 70.9% to 83.6%; minimum 47.1%; maximum 95.8%). There were 64 initial conventional intubation low-performing and 45 high-performing EMS agencies. In this national series, EMS advanced airway management and initial conventional intubation performance varied widely. Reliability adjustment and risk standardization may influence EMS airway management performance assessments. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Bayesian adaptive phase II screening design for combination trials.
Cai, Chunyan; Yuan, Ying; Johnson, Valen E
2013-01-01
Trials of combination therapies for the treatment of cancer are playing an increasingly important role in the battle against this disease. To more efficiently handle the large number of combination therapies that must be tested, we propose a novel Bayesian phase II adaptive screening design to simultaneously select among possible treatment combinations involving multiple agents. Our design is based on formulating the selection procedure as a Bayesian hypothesis testing problem in which the superiority of each treatment combination is equated to a single hypothesis. During the trial conduct, we use the current values of the posterior probabilities of all hypotheses to adaptively allocate patients to treatment combinations. Simulation studies show that the proposed design substantially outperforms the conventional multiarm balanced factorial trial design. The proposed design yields a significantly higher probability for selecting the best treatment while allocating substantially more patients to efficacious treatments. The proposed design is most appropriate for the trials combining multiple agents and screening out the efficacious combination to be further investigated. The proposed Bayesian adaptive phase II screening design substantially outperformed the conventional complete factorial design. Our design allocates more patients to better treatments while providing higher power to identify the best treatment at the end of the trial.
Vorpahl, Marc; Koehler, Till; Foerst, Jason; Panagiotopoulos, Spyridon; Schleiting, Heinrich; Koss, Klaus; Ziegler, Gunda; Brinkmann, Hilmar; Seyfarth, Melchior; Tiroch, Klaus
2015-01-01
Current guidelines favor the radial approach for coronary angiography. Therefore, specialty radial diagnostic catheters were designed to engage both coronary arteries with a single device. However, it is unclear if single catheters are superior to conventional catheters. A retrospective analysis was performed of consecutive right radial coronary angiographies to determine catheter use, fluoroscopy time, radiation dosage, and consumption of contrast. Procedures were performed with a single TIG catheter or conventional catheters (CONV). Procedures with coronary artery bypass grafts or ventricular angiographies were excluded. 273 transradial procedures were performed successfully. 95 procedures were performed with CONV and 178 procedures with a TIG. Crossover to additional catheters was higher in TIG (15.2%) compared to CONV (5.3%, p = 0.02). Fluoroscopy time was comparable between CONV and TIG, without crossover (2.2 ± 1.2 min versus 2.3 ± 1.2 min; n.s.), however, greater in the case of crossover for CONV (5.8 ± 0.7) and TIG (7.6 ± 3.0; p = 0.0001). Radiation dosage was similar in CONV and the TIG, without crossover (1419 ± 1075, cGy∗cm(2) versus 1690 ± 1138; n.s.), however, greater for CONV (2374 ± 620) and TIG (3733 ± 2281, p = 0.05) with crossover. Overall, the amount of contrast was greater in TIG (56 ± 13 mL) versus CONV (48 ± 3 mL; p = 0.0003). CONV femoral catheters may be the primary choice for radial approach.
On the comprehensibility and perceived privacy protection of indirect questioning techniques.
Hoffmann, Adrian; Waubert de Puiseau, Berenike; Schmidt, Alexander F; Musch, Jochen
2017-08-01
On surveys that assess sensitive personal attributes, indirect questioning aims at increasing respondents' willingness to answer truthfully by protecting confidentiality. However, the assumption that subjects understand questioning procedures fully and trust them to protect their privacy is rarely tested. In a scenario-based design, we compared four indirect questioning procedures in terms of their comprehensibility and perceived privacy protection. All indirect questioning techniques were found to be less comprehensible by respondents than a conventional direct question used for comparison. Less-educated respondents experienced more difficulties when confronted with any indirect questioning technique. Regardless of education, the crosswise model was found to be the most comprehensible among the four indirect methods. Indirect questioning in general was perceived to increase privacy protection in comparison to a direct question. Unexpectedly, comprehension and perceived privacy protection did not correlate. We recommend assessing these factors separately in future evaluations of indirect questioning.
Determination of molybenum in soils and rocks: A geochemical semimicro field method
Ward, F.N.
1951-01-01
Reconnaissance work in geochemical prospecting requires a simple, rapid, and moderately accurate method for the determination of small amounts of molybdenum in soils and rocks. The useful range of the suggested procedure is from 1 to 32 p.p.m. of molybdenum, but the upper limit can be extended. Duplicate determinations on eight soil samples containing less than 10 p.p.m. of molybdenum agree within 1 p.p.m., and a comparison of field results with those obtained by a conventional laboratory procedure shows that the method is sufficiently accurate for use in geochemical prospecting. The time required for analysis and the quantities of reagents needed have been decreased to provide essentially a "test tube" method for the determination of molybdenum in soils and rocks. With a minimum amount of skill, one analyst can make 30 molybdenum determinations in an 8-hour day.
Predicting hydration free energies of amphetamine-type stimulants with a customized molecular model
NASA Astrophysics Data System (ADS)
Li, Jipeng; Fu, Jia; Huang, Xing; Lu, Diannan; Wu, Jianzhong
2016-09-01
Amphetamine-type stimulants (ATS) are a group of incitation and psychedelic drugs affecting the central nervous system. Physicochemical data for these compounds are essential for understanding the stimulating mechanism, for assessing their environmental impacts, and for developing new drug detection methods. However, experimental data are scarce due to tight regulation of such illicit drugs, yet conventional methods to estimate their properties are often unreliable. Here we introduce a tailor-made multiscale procedure for predicting the hydration free energies and the solvation structures of ATS molecules by a combination of first principles calculations and the classical density functional theory. We demonstrate that the multiscale procedure performs well for a training set with similar molecular characteristics and yields good agreement with a testing set not used in the training. The theoretical predictions serve as a benchmark for the missing experimental data and, importantly, provide microscopic insights into manipulating the hydrophobicity of ATS compounds by chemical modifications.
Assessment of Pb, Cd, Cr and Ag leaching from electronics waste using four extraction methods.
Keith, Ashley; Keesling, Kara; Fitzwater, Kendra K; Pichtel, John; Houy, Denise
2008-12-01
Heavy metals present in electronic components may leach upon disposal and therefore pose significant environmental hazards. The potential leaching of Pb, Cd, Cr and Ag from PC cathode ray tubes, printed circuit boards (PCBs), PC mice, TV remote controls, and mobile phones was assessed. After controlled crushing, each component was extracted using the Toxicity Characteristic Leaching Procedure (TCLP), EPA Method 1312 (SPLP), NEN 7371 (Dutch Environmental Agency), and DIN S4 (Germany). The TCLP consistently leached the greatest amounts of Pb from all components. The SPLP, NEN 7371 and DIN S4 extracted relatively small amounts of metals compared with the TCLP and were not considered effective as leaching tests for e-waste. The smallest size fraction (< 2 mm) of CRT glass and PCBs leached significantly (p < 0.05) highest Pb via the TCLP. A modified TCLP removed 50.9% more extractable Pb compared with the conventional procedure.
Berger, C; Berger, B; Parson, W
2012-01-01
In recent years, evidence from domestic dogs has increasingly been analyzed by forensic DNA testing. Especially, canine hairs have proved most suitable and practical due to the high rate of hair transfer occurring between dogs and humans. Starting with the description of a contamination-free sample handling procedure, we give a detailed workflow for sequencing hypervariable segments (HVS) of the mtDNA control region from canine evidence. After the hair material is lysed and the DNA extracted by Phenol/Chloroform, the amplification and sequencing strategy comprises the HVS I and II of the canine control region and is optimized for DNA of medium-to-low quality and quantity. The sequencing procedure is based on the Sanger Big-dye deoxy-terminator method and the separation of the sequencing reaction products is performed on a conventional multicolor fluorescence detection capillary electrophoresis platform. Finally, software-aided base calling and sequence interpretation are addressed exemplarily.
Human factors research on performance-based navigation instrument procedures for NextGEN
DOT National Transportation Integrated Search
2012-10-14
Area navigation (RNAV) and required navigation performance (RNP) are key components of performance-based navigation (PBN). Instrument procedures that use RNAV and RNP can have more flexible and precise paths than conventional routes that are defined ...
Effectiveness of rapid prescreening and 10% rescreening in liquid-based Papanicolaou testing.
Currens, Heather S; Nejkauf, Katharine; Wagner, Lynn; Raab, Stephen S
2012-01-01
Although rapid prescreening (RPS) has been shown to be an effective quality control procedure for detecting false-negative conventional Papanicolaou (Pap) tests, RPS has not been widely implemented in the United States. In our laboratory, cytotechnologists performed RPS in 3,567 liquid-based Pap tests: 1,911 SurePath (BD Diagnostics-TriPath, Burlington, NC) preparations that were manually screened and 1,656 ThinPrep Pap tests (Hologic, Bedford, MA) that were imaged using the ThinPrep Imaging System (Hologic). We compared the sensitivity of RPS, 10% rescreening (R-10%), and routine screening (RS). In contrast with previously published findings, we found that RS + RPS did not improve screening sensitivity compared with RS + R-10%. These results support the following hypotheses: (1) Higher baseline RS sensitivity as a result of Pap test diagnoses standardization implemented for quality improvement purposes decreases the performance impact of RPS. (2) R-10% and RPS quality assurance methods detect diagnostic failures caused by different types of cognitive errors.
Ramcharitar, Steve; van der Giessen, Willem J; van der Ent, Martin; de Feyter, Pim; Serruys, Patrick W; van Geuns, Robert-Jan
2011-01-01
Applying the Magnetic Navigation System (MNS) to manage chronic total occlusions (CTOs). The MNS precisely directs a magnetised guidewire in vivo through two permanent external magnets. The first 43 consecutive MNS treated CTOs were retrospectively evaluated. Computed tomography coronary angiography (CTCA) co-integration with the MNS provided a virtual road map through the occlusion. Unsuccessful MNS cases were managed with bailout conventional guidewire techniques. Experienced CTO and MNS operators had unrestricted access to CTO devices and equipments. The MNS crossing success increased from 40% to 56% over 52 months and averaged 44.2% (19/43 patients). In 58.3% (14/24) of failed MNS cases the conventional wire approach was successful, giving an overall procedural success rate of 76.6%. Of those conventionally treated, two patients required pericardiocentesis. On average, 1.8 ± 0.9 stents (lengths 44.7 ± 21.4 mm and diameter 2.8 ± 0.4 mm) were implanted. Procedural times were lengthy (125.0 ± 35.3 min) requiring high fluoroscopy dosage (11980.2 ± 6457.9 Gy/cm2) and contrast media usage (388.8 ± 170.2 ml). Operators persevered less with magnetic wires (20.9 ± 12.4 min vs. 27.7 ± 24.4 min), and preferentially used the least stiff wire as first choice (53.5%). CTCA co-integration did not influence procedural outcome. As with conventional wires, higher magnetic wire successes occurred in low calcified lesions, those with a central stump and without bridging collaterals. In unselected CTOs, the magnetic wires are safe and feasible. Current modest success rates with a high procedural bailout rate implicate the need for improved magnetic guidewire technology comparable to available sophisticated conventional CTO wires. Randomised studies are needed to clarify the value of magnetic guided recanalisation.
Tooth-supported, magnet-retained overdentures: a review.
Vere, Joe; Deans, Robert F
2009-06-01
There has been an increase in the provision of implant-supported prostheses in patients unable to tolerate conventional dentures. Unfortunately, many patients are unable to benefit from this treatment option because of anatomical, medical or financial constraints. Magnet-retained overdentures represent a potential treatment option in many of these cases. This article describes the development, advantages, complications and clinical procedures associated with the provision of tooth-supported, magnet-retained overdentures. Conventional overdenture retention can be enhanced by the use of dental magnets. Clinical procedures are straightforward and magnets offer a number of advantages over other forms of precision attachment.
Animal models of 'anxiety': where next?
Rodgers, R J
1997-11-01
Numerous procedures have been developed to facilitate preclinical research on the behavioural pharmacology of anxiety and, as a result of this application, are often referred to as animal models of 'anxiety'. This is an unfortunate misnomer, not only because of the apparent inability of many tests to detect novel anxiolytics consistently, but also because the term implies that anxiety is a unitary emotion. Such difficulties have arisen largely as a consequence of test development strategies which, by emphasizing pharmacological (i.e. benzodiazepine) validation, have yielded models predictive of a specific type of anxiolytic activity. The present review argues that the refinement of existing tests as well as the development of new procedures requires urgent attention to the much neglected issue of behavioural validation. From an evolutionary perspective, normal human anxiety may be conceptualized as a repertoire of defence reactions tailored to meet different forms of threats, and disorders of anxiety as the inappropriate activation or exaggeration of these usually adaptive response patterns. In this context, consideration of the defensive reactions typically observed in our animal models reveals substantially greater commonality in the behavioural effects of benzodiazepine and 5-HT1A anxiolytics than would otherwise be apparent. Therefore, with the exception of the conventional plus-maze paradigm (discussed at some length), better correspondence is seen in tests involving unconditioned response to potential threat (e.g. social interaction, distress vocalizations and light/dark exploration) than in tests of conditioned fear reactions. Even within the latter grouping, however, greater commonality is seen in procedures based on reactions to proximal threat (e.g. freezing, startle, ultrasonic vocalizations, burying) than those involving reactions to distal threat (e.g. avoidance/flight). Significantly, very similar findings have been reported in tests specifically designed to study defensive reactions (e.g. rat and mouse defence test batteries) or which incorporate a more detailed knowledge of defence into established procedures (e.g. ethological plus-maze and defensive burying paradigms). Furthermore, recent evidence also suggests that drugs with proved clinical efficacy in panic attacks/panic disorder have reliably stronger effects on flight responses than other components of the defensive repertoire. It is concluded that a focus on defensive behaviour patterns improves test validity (predictive/face/construct), offers a more rational basis for test selection in drug development programmes, and provides a firmer theoretical framework for future methodological and therapeutic advance.
Outcomes of repeat catheter ablation using magnetic navigation or conventional ablation.
Akca, Ferdi; Theuns, Dominic A M J; Abkenari, Lara Dabiri; de Groot, Natasja M S; Jordaens, Luc; Szili-Torok, Tamas
2013-10-01
After initial catheter ablation, repeat procedures could be necessary. This study evaluates the efficacy of the magnetic navigation system (MNS) in repeat catheter ablation as compared with manual conventional techniques (MANs). The results of 163 repeat ablation procedures were analysed. Ablations were performed either using MNS (n = 84) or conventional manual ablation (n = 79). Procedures were divided into four groups based on the technique used during the initial and repeat ablation procedure: MAN-MAN (n = 66), MAN-MNS (n = 31), MNS-MNS (n = 53), and MNS-MAN (n = 13). Three subgroups were analysed: supraventricular tachycardias (SVTs, n = 68), atrial fibrillation (AF, n = 67), and ventricular tachycardias (VT, n = 28). Recurrences were assessed during 19 ± 11 months follow-up. Overall, repeat procedures using MNS were successful in 89.0% as compared with 96.2% in the MAN group (P = ns). The overall recurrence rate was significantly lower using MNS (25.0 vs. 41.4%, P = 0.045). Acute success and recurrence rates for the MAN-MAN, MAN-MNS, MNS-MNS, and MNS-MAN groups were comparable. For the SVT subgroup a higher acute success rate was achieved using MAN (87.9 vs. 100.0%, P = 0.049). The use of MNS for SVT is associated with longer procedure times (205 ± 82 vs. 172 ± 69 min, P = 0.040). For AF procedure and fluoroscopy times were longer (257 ± 72 vs. 185 ± 64, P = 0.001; 59.5 ± 19.3 vs. 41.1 ± 18.3 min, P < 0.001). Less fluoroscopy was used for MNS-guided VT procedures (22.8 ± 14.7 vs. 41.2 ± 10.9, P = 0.011). Our data suggest that overall MNS is comparable with MAN in acute success after repeat catheter ablation. However, MNS is related to fewer recurrences as compared with MAN.
Effect of curing mode on the micro-mechanical properties of dual-cured self-adhesive resin cements.
Ilie, Nicoleta; Simon, Alexander
2012-04-01
Light supplying to luting resin cements is impeded in several clinical situations, causing us to question whether materials can properly be cured to achieve adequately (or adequate) mechanical properties. The aim of this study was therefore to analyse the effect of light on the micro-mechanical properties of eight popular dual-cured self-adhesive resin cements by comparing them with two conventional, also dual-cured, resin cements. Four different curing procedures were applied: auto-polymerisation (dark curing) and light curing (LED unit, Freelight 2, 20 s) by applying the unit directly on the samples' surface, at a distance of 5 and 10 mm. Twenty minutes after curing, the samples were stored for 1 week at 37°C in a water-saturated atmosphere. The micro-mechanical properties-Vickers hardness, modulus of elasticity, creep and elastic/plastic deformation-were measured. Data were analysed with multivariate ANOVA followed by Tukey's test and partial eta-squared statistics (p < 0.05). A very strong influence of the material as well as filler volume and weight on the micro-mechanical properties was measured, whereas the influence of the curing procedure and type of cement-conventional or self-adhesive-was generally low. The influence of light on the polymerisation process was material dependent, with four different behaviour patterns to be distinguished. As a material category, significantly higher micro-mechanical properties were measured for the conventional compared to the self-adhesive resin cements, although this difference was low. Within the self-adhesive resin cements group, the variation in micro-mechanical properties was high. The selection of suitable resin cements should be done by considering, besides its adhesive properties, its micro-mechanical properties and curing behaviour also.
Marte, Antonio; Pintozzi, Lucia; Cavaiuolo, Silvia; Parmeggiani, Pio
2014-01-01
Single-incision laparoscopic surgery (SILS) has gained great popularity in paediatric surgery due to its minimally invasive approach and improved cosmetic results. Notwithstanding, reports describing its adoption in children are still fragmentary and some perplexities have been raised by some surgeons. We reviewed our experience with the SILS Palomo varicocelectomy procedure (SIL-V) in children and adolescents, comparing this group with a similar series operated using conventional laparoscopic varicocelectomy (CL-V). A total of 69 Palomo laparoscopic varicocelectomies were performed in patients aged 11-17 years from January 2011 to January 2013. Indications for surgery included grades II-III varicocele or ipsilateral testicular hypotrophy. The SIL-V procedure was performed in 44 patients with roticulating and conventional 5 mm instruments. Testicular vessels were isolated "en bloc," clipped and cut. Operating time, visual analogue scale and post-operative results were compared to a similar group of 25 patients operated with CL-V. No patient of the SIL-V group required conversion to conventional laparoscopy, none to open surgery. Mean operative time was 22 min (range: 19-28) in the SIL-V group, not significantly different compared with CL-V (mean 21 min, range: 18-25). All patients experienced a smooth recovery from surgery without any complications, and were discharged on day 1. No difficulties were found in the SIL-V group. The post-operative pain score was significantly better in SIL-V. The SIL-V procedure is safe and effective and allows a fast and efficient isolation of the vascular bundle. The use of conventional instruments is technically feasible in SIL-V.
Combined effect of gamma-irradiation and conventional cooking on Aeromonas hydrophila in meatball.
Ozbaş, Z Y; Vural, H; Aytaç, S A
1996-01-01
Irradiation combined with a conventional cooking procedure was applied to meatball and the effects on bacterial load and inoculated Aeromonas hydrophila were determined. Meatball samples were irradiated by using a 60Co source at the dose levels of 0, 0.30, 0.75, 1.50, 2.50 kGy and cold stored at 4 +/- 1 degrees C for 7 days. Bacterial load and the count of A. hydrophila decreased when the irradiation dose level increased. A minimum inhibition effect was found at the dose of 0.30 kGy. Irradiation in combination with a conventional cooking procedure was found to be more effective in reducing A. hydrophila and the bacterial load in meatball. This study indicated that a dose of 0.75 kGy was sufficient to destroy approximately 10(4) cfu/g of A. hydrophila in meatball.
Merchant, Roland C.; Clark, Melissa A.; Seage, George R.; Mayer, Kenneth H.; DeGruttola, Victor G.; Becker, Bruce M.
2011-01-01
The aim of this investigation was to assess emergency department (ED) patients’ perceptions and preferences about an opt-in, universal, rapid HIV screening program and identify patient groups who expressed stronger beliefs about components of the testing program. From July 2005 to July 2006, ED patients in the opt-in, universal, rapid HIV screening program were interviewed in person. Multivariable regression models were used to compare participants on their beliefs about the program components. Of the 561 participants, 62.0% had previously been tested for HIV. The majority of participants (58.8%) believed the rapid and standard/conventional HIV tests to be equally accurate, 27.7% believed the rapid test to be less or much less accurate, and 8.7% believed the rapid test to be more or much more accurate. Almost two-thirds (65.1%) favored having a rapid instead of a standard/conventional HIV test, 94.6% wanted the test results within one hour, and 61.3% would be likely or very likely to undergo testing in the ED if it prolonged their ED visit. Almost all (92.5%) believed that their medical care was “not at all” delayed because of being tested, 94.1% believed that testing did “not at all” divert attention from the reason for their ED visit, and 80.9% thought that testing in the ED was “not at all” stressful. In multivariable logistic regression models, males and those with more than 12 years of formal education showed greater concerns about the rapid HIV test’s accuracy. Hispanic/Latinos, participants with governmental insurance, and those previously HIV tested were more apt to be screened for HIV even if testing delayed their ED departure. Overall, participants were highly accepting of the components of this opt-in rapid HIV screening program. However, concerns regarding the accuracy of the rapid HIV test might limit test acceptance and should be addressed during pre-test information procedures. PMID:19283644
USDA-ARS?s Scientific Manuscript database
Service-sire conception rate (SCR), a phenotypic fertility evaluation based on conventional (nonsexed) inseminations from parities 1 through 5, was implemented by USDA in August 2008. Using insemination data from 2005 through 2009, the SCR procedure was applied separately for nulliparous heifer inse...
Benic, Goran I; Mühlemann, Sven; Fehmer, Vincent; Hämmerle, Christoph H F; Sailer, Irena
2016-11-01
Trials comparing the overall performance of fully digital and conventional workflows in reconstructive dentistry are needed. The purpose of the first part of this randomized controlled clinical trial was to determine whether optical impressions produce different results from conventional impressions with respect to time efficiency and patient and operator perceptions of the clinical workflow. Three digital impressions and 1 conventional impression were made in each of 10 participants according to a randomly generated sequence. The digital systems were Lava COS, iTero, and Cerec Bluecam. The conventional impression was made with the closed-mouth technique and polyvinyl siloxane material. The time needed for powdering, impressions, and interocclusal record was recorded. Patient and clinician perceptions of the procedures were rated by means of visual analog scales. The paired t test with Bonferroni correction was applied to detect differences (α=.05/6=.0083). The mean total working time ±standard deviation amounted to 260 ±66 seconds for the conventional impression, 493 ±193 seconds for Lava, 372 ±126 seconds for iTero, and 357 ±55 seconds for Cerec. The total working time for the conventional impression was significantly lower than that for Lava and Cerec. With regard to the working time without powdering, the differences between the methods were not statistically significant. The patient rating (very uncomfortable=0; comfortable=100) measured 61 ±34 for conventional impression, 71 ±18 for Lava, 66 ±20 for iTero, and 48 ±18 for Cerec. The differences were not statistically significant. The clinician rating (simple=0; very difficult=100) was 13 ±13 for the conventional impression, 54 ±27 for Lava, 22 ±11 for iTero, and 36 ±23 for Cerec. The differences between the conventional impression and Lava and between iTero and Lava were statistically significant. The conventional impression was more time-effective than the digital impressions. In terms of patient comfort, no differences were found between the conventional and the digital techniques. With respect to the clinician perception of difficulty, the conventional impression and the digital impression with iTero revealed more favorable outcomes than the digital impression with Lava. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Szep, Susanne; Schmid, Claudia; Weigl, Paul; Hahn, Lothar; Heidemann, Detlef
2003-01-01
There is no evidence-based information on how ceramic restorations with an adhesive bond between restoration material and composite cement may be influenced by a silicone disclosing agent. The aim of this study was to determine the effects of the silicone disclosing procedure on the shear bond strength of composite cements in the luting of industrial sintered and laboratory sintered ceramic restorations. Thirty standardized (15 x 10 x 9 mm) prefabricated ceramic specimens (Groups 1, 3, 5) and 30 standardized (15 x10 x 9 mm) conventionally sintered ceramic specimens (Groups 2, 4, 6) were roughened with sandpaper (800-grit). Each group contained 10 specimens. Groups 3 and 4 were conditioned with hydrofluoric acid and primed with silane solution after the use of a silicone disclosing procedure. Groups 1 and 2 served as the control groups, where no silicone disclosing procedure was performed. Groups 5 and 6 were insulated with glycerine before the silicone disclosing procedure. A glass tube (4.5 mm in diameter) was used to apply a cylinder of dual-polymerized composite cement to the conditioned surfaces. All specimens were submitted to 5000 thermocycles (5 degrees to 55 degrees C) to simulate the in vivo situation. The specimens were subjected to a shear-pull test at a constant crosshead speed of 5 mm/min with a universal testing machine. The comparative shear bond strengths were analyzed by use of Duncan's test (alpha=0.05). Shear bond strength values for Groups 1 (9.86 +/- 4.97 MPa) and 2 (9.56 +/- 4.47 Mpa) were obtained with no significant differences. Lower but significantly undifferent values were obtained for Groups 3 (7.49 +/- 4.67 MPa) and 4 (7.62 +/- 3.49 MPa) after the use of a silicone disclosing procedure. In Groups 5 (8.21 +/- 4.75 MPa) and 6 (8.22 +/- 3.59 MPa), including insulation with glycerine before the silicone disclosing procedure, no significant differences were obtained. Within the limitations of this study, the use of silicone disclosing procedures before conditioning the ceramic surface did not lead to a significant reduction of the shear bond strength between ceramic and composite cement. The ceramic materials used (industrial-sintered versus laboratory-sintered ceramic) had no significant influence on adhesion.
15 CFR 719.15 - Procedural stipulations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Procedural stipulations. 719.15 Section 719.15 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...
15 CFR 719.15 - Procedural stipulations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 15 Commerce and Foreign Trade 2 2011-01-01 2011-01-01 false Procedural stipulations. 719.15 Section 719.15 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) BUREAU OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS...
Pitarch, Elena; Hernandez, Felix; ten Hove, Jan; Meiring, Hugo; Niesing, Willem; Dijkman, Ellen; Stolker, Linda; Hogendoorn, Elbert
2004-03-26
We have investigated the potential of capillary-column-switching liquid chromatography coupled to tandem mass spectrometry (cLC-MS-MS) for the quantitative on-line trace analysis of target compounds in aqueous solutions. The technical design of the nano-scale cLC system developed at our Institute for peptide and protein identification has been tested and evaluated for the direct trace analysis of drugs in water samples. Sulphametoxazole, bezafibrate, metoprolol, carbamazepine and bisoprolol occurring frequently in Dutch waters, were selected as test compounds. Adequate conditions for trapping, elution and MS-MS detection were investigated by employing laboratory made 200 microm i.d. capillary columns packed with 5 microm aqua C18 material. In the final cLC-MS-MS conditions, a 1 cm length trapping column and a 4 cm length analytical column were selected. Under these conditions, the target compounds could be directly determined in water down to a level of around 50 ng/l employing only 25 microl of water sample. Validation was done by recovery experiments in ground-, surface- and drinking-water matrices as well as by the analysis of water samples with incurred residues and previously analyzed with a conventional procedure involving off-line solid-phase extraction and narrow-bore LC with MS-MS detection. The new methodology provided recoveries (50-500 ng/l level) between 50 and 114% with RSDs (n = 3, each level) below 20% for most of the compounds. Despite the somewhat less analytical performance in comparison to the conventional procedure, the on-line approach of the new methodology is very suitable for screening of drugs in aqueous samples.
Han, Peng; Lei, Chao-Liang; Cui, Jin-Jie; Desneux, Nicolas
2010-01-01
Transgenic Cry1Ac+CpTI cotton (CCRI41) is a promising cotton cultivar throughout China but side effects and especially sublethal effects of this transgenic cultivar on beneficial insects remain poorly studied. More specifically potential sublethal effects on behavioural traits of the honey bee Apis mellifera L. have not been formally assessed despite the importance of honey bees for pollination. The goal of our study was to assess potential effects of CCRI41 cotton pollen on visual and olfactory learning by honey bees. After a 7-day oral chronic exposure to honey mixed with either CCRI41 pollen, imidacloprid-treated conventional pollen (used as positive sublethal control) or conventional pollen (control), learning performance was evaluated by the classical proboscis extension reflex (PER) procedure as well as a T-tube maze test. The latter assay was designed as a new device to assess potential side effects of pesticides on visual associative learning of honey bees. These two procedures were complementary because the former focused on olfactory learning while the latter was involved in visual learning based on visual orientation ability. Oral exposure to CCRI41 pollen did not affect learning capacities of honey bees in both the T-tube maze and PER tests. However, exposure to imidacloprid resulted in reduced visual learning capacities in T-tube maze evaluation and decreased olfactory learning performances measured with PER. The implications of these results are discussed in terms of risks of transgenic CCRI41 cotton crops for honey bees. PMID:20872243
Aluminum alloy AA-6061 and RSA-6061 heat treatment for large mirror applications
NASA Astrophysics Data System (ADS)
Newswander, T.; Crowther, B.; Gubbels, G.; Senden, R.
2013-09-01
Aluminum mirrors and telescopes can be built to perform well if the material is processed correctly and can be relatively low cost and short schedule. However, the difficulty of making high quality aluminum telescopes increases as the size increases, starting with uniform heat treatment through the thickness of large mirror substrates. A risk reduction effort was started to build and test a ½ meter diameter super polished aluminum mirror. Material selection, the heat treatment process and stabilization are the first critical steps to building a successful mirror. In this study, large aluminum blanks of both conventional AA-6061 per AMS-A-22771 and RSA AA-6061 were built, heat treated and stress relieved. Both blanks were destructively tested with a cut through the thickness. Hardness measurements and tensile tests were completed. We present our results in this paper and make suggestions for modification of procedures and future work.
Computer-aided analysis for the Mechanics of Granular Materials (MGM) experiment, part 2
NASA Technical Reports Server (NTRS)
Parker, Joey K.
1987-01-01
Computer vision based analysis for the MGM experiment is continued and expanded into new areas. Volumetric strains of granular material triaxial test specimens have been measured from digitized images. A computer-assisted procedure is used to identify the edges of the specimen, and the edges are used in a 3-D model to estimate specimen volume. The results of this technique compare favorably to conventional measurements. A simplified model of the magnification caused by diffraction of light within the water of the test apparatus was also developed. This model yields good results when the distance between the camera and the test specimen is large compared to the specimen height. An algorithm for a more accurate 3-D magnification correction is also presented. The use of composite and RGB (red-green-blue) color cameras is discussed and potentially significant benefits from using an RGB camera are presented.
Fabrication of VB2/Air Cells for Electrochemical Testing
Stuart, Jessica; Lopez, Ruben; Lau, Jason; Li, Xuguang; Waje, Mahesh; Mullings, Matthew; Rhodes, Christopher; Licht, Stuart
2013-01-01
A technique to investigate the properties and performance of new multi-electron metal/air battery systems is proposed and presented. A method for synthesizing nanoscopic VB2 is presented as well as step-by-step procedure for applying a zirconium oxide coating to the VB2 particles for stabilization upon discharge. The process for disassembling existing zinc/air cells is shown, in addition construction of the new working electrode to replace the conventional zinc/air cell anode with a the nanoscopic VB2 anode. Finally, discharge of the completed VB2/air battery is reported. We show that using the zinc/air cell as a test bed is useful to provide a consistent configuration to study the performance of the high-energy high capacity nanoscopic VB2 anode. PMID:23962835
Note: Tesla based pulse generator for electrical breakdown study of liquid dielectrics
NASA Astrophysics Data System (ADS)
Veda Prakash, G.; Kumar, R.; Patel, J.; Saurabh, K.; Shyam, A.
2013-12-01
In the process of studying charge holding capability and delay time for breakdown in liquids under nanosecond (ns) time scales, a Tesla based pulse generator has been developed. Pulse generator is a combination of Tesla transformer, pulse forming line, a fast closing switch, and test chamber. Use of Tesla transformer over conventional Marx generators makes the pulse generator very compact, cost effective, and requires less maintenance. The system has been designed and developed to deliver maximum output voltage of 300 kV and rise time of the order of tens of nanoseconds. The paper deals with the system design parameters, breakdown test procedure, and various experimental results. To validate the pulse generator performance, experimental results have been compared with PSPICE simulation software and are in good agreement with simulation results.
Flight Test Results: CTAS Cruise/Descent Trajectory Prediction Accuracy for En route ATC Advisories
NASA Technical Reports Server (NTRS)
Green, S.; Grace, M.; Williams, D.
1999-01-01
The Center/TRACON Automation System (CTAS), under development at NASA Ames Research Center, is designed to assist controllers with the management and control of air traffic transitioning to/from congested airspace. This paper focuses on the transition from the en route environment, to high-density terminal airspace, under a time-based arrival-metering constraint. Two flight tests were conducted at the Denver Air Route Traffic Control Center (ARTCC) to study trajectory-prediction accuracy, the key to accurate Decision Support Tool advisories such as conflict detection/resolution and fuel-efficient metering conformance. In collaboration with NASA Langley Research Center, these test were part of an overall effort to research systems and procedures for the integration of CTAS and flight management systems (FMS). The Langley Transport Systems Research Vehicle Boeing 737 airplane flew a combined total of 58 cruise-arrival trajectory runs while following CTAS clearance advisories. Actual trajectories of the airplane were compared to CTAS and FMS predictions to measure trajectory-prediction accuracy and identify the primary sources of error for both. The research airplane was used to evaluate several levels of cockpit automation ranging from conventional avionics to a performance-based vertical navigation (VNAV) FMS. Trajectory prediction accuracy was analyzed with respect to both ARTCC radar tracking and GPS-based aircraft measurements. This paper presents detailed results describing the trajectory accuracy and error sources. Although differences were found in both accuracy and error sources, CTAS accuracy was comparable to the FMS in terms of both meter-fix arrival-time performance (in support of metering) and 4D-trajectory prediction (key to conflict prediction). Overall arrival time errors (mean plus standard deviation) were measured to be approximately 24 seconds during the first flight test (23 runs) and 15 seconds during the second flight test (25 runs). The major source of error during these tests was found to be the predicted winds aloft used by CTAS. Position and velocity estimates of the airplane provided to CTAS by the ATC Host radar tracker were found to be a relatively insignificant error source for the trajectory conditions evaluated. Airplane performance modeling errors within CTAS were found to not significantly affect arrival time errors when the constrained descent procedures were used. The most significant effect related to the flight guidance was observed to be the cross-track and turn-overshoot errors associated with conventional VOR guidance. Lateral navigation (LNAV) guidance significantly reduced both the cross-track and turn-overshoot error. Pilot procedures and VNAV guidance were found to significantly reduce the vertical profile errors associated with atmospheric and aircraft performance model errors.
Assessment of tear osmolarity and other dry eye parameters in post-LASIK eyes.
Hassan, Ziad; Szalai, Eszter; Berta, Andras; Modis, Laszlo; Nemeth, Gabor
2013-07-01
To assess the tear osmolarity using the TearLab device after laser in situ keratomileusis (LASIK) and to compare the values with those obtained by traditional tear film tests before and after the procedure. Thirty eyes of 15 refractive surgery candidates (5 men and 10 women of mean age: 30.55 ± 11.79 years) were examined. Using a special questionnaire (Ocular Surface Disease Index), subjective dry eye complaints were evaluated, and then, the tear osmolarity was measured with the TearLab system (TearLab Corporation) and conventional dry eye tests were carried out. Examinations were performed preoperatively and at 1, 30, and 60 days after the surgery. The mean value of tear osmolarity was 303.62 ± 12.29 mOsm/L before the surgery and 303.58 ± 20.14 mOsm/L at 60 days after the treatment (P = 0.69). Mean lid parallel conjunctival folds value was 0.68 ± 0.68 before the procedure and 0.58 ± 0.65 subsequent to surgery (P = 0.25). Meibomian gland dysfunction was not detected. No significant deviation was observed in the values of Schirmer test, corneal staining, tear break-up time, and lid parallel conjunctival folds when compared with postoperatively obtained values during the follow-up period (P > 0.05). During LASIK flap creation, intact corneal innervation is damaged, and the ocular surface lacrimal functional unit can be impaired. In our study, no abnormal dry eye test results were observed before or after the procedure. Based on our results, LASIK treatment is safe for dry eye involving the administration of adequate artificial tears for a minimum of 3 months.
Renz, Nora; Cabric, Sabrina; Morgenstern, Christian; Schuetz, Michael A; Trampuz, Andrej
2018-04-01
Bone healing disturbance following fracture fixation represents a continuing challenge. We evaluated a novel fully automated polymerase chain reaction (PCR) assay using sonication fluid from retrieved orthopedic hardware to diagnose infection. In this prospective diagnostic cohort study, explanted orthopedic hardware materials from consecutive patients were investigated by sonication and the resulting sonication fluid was analyzed by culture (standard procedure) and multiplex PCR (investigational procedure). Hardware-associated infection was defined as visible purulence, presence of a sinus tract, implant on view, inflammation in peri-implant tissue or positive culture. McNemar's chi-squared test was used to compare the performance of diagnostic tests. For the clinical performance all pathogens were considered, whereas for analytical performance only microorganisms were considered for which primers are included in the PCR assay. Among 51 patients, hardware-associated infection was diagnosed in 38 cases (75%) and non-infectious causes in 13 patients (25%). The sensitivity for diagnosing infection was 66% for peri-implant tissue culture, 84% for sonication fluid culture, 71% (clinical performance) and 77% (analytical performance) for sonication fluid PCR, the specificity of all tests was >90%. The analytical sensitivity of PCR was higher for gram-negative bacilli (100%), coagulase-negative staphylococci (89%) and Staphylococcus aureus (75%) than for Cutibacterium (formerly Propionibacterium) acnes (57%), enterococci (50%) and Candida spp. (25%). The performance of sonication fluid PCR for diagnosis of orthopedic hardware-associated infection was comparable to culture tests. The additional advantage of PCR was short processing time (<5 h) and fully automated procedure. With further improvement of the performance, PCR has the potential to complement conventional cultures. Copyright © 2018 Elsevier Ltd. All rights reserved.
Magnetic navigation in ultrasound-guided interventional radiology procedures.
Xu, H-X; Lu, M-D; Liu, L-N; Guo, L-H
2012-05-01
To evaluate the usefulness of magnetic navigation in ultrasound (US)-guided interventional procedures. Thirty-seven patients who were scheduled for US-guided interventional procedures (20 liver cancer ablation procedures and 17 other procedures) were included. Magnetic navigation with three-dimensional (3D) computed tomography (CT), magnetic resonance imaging (MRI), 3D US, and position-marking magnetic navigation were used for guidance. The influence on clinical outcome was also evaluated. Magnetic navigation facilitated applicator placement in 15 of 20 ablation procedures for liver cancer in which multiple ablations were performed; enhanced guidance in two small liver cancers invisible on conventional US but visible at CT or MRI; and depicted the residual viable tumour after transcatheter arterial chemoembolization for liver cancer in one procedure. In four of 17 other interventional procedures, position-marking magnetic navigation increased the visualization of the needle tip. Magnetic navigation was beneficial in 11 (55%) of 20 ablation procedures; increased confidence but did not change management in five (25%); added some information but did not change management in two (10%); and made no change in two (10%). In the other 17 interventional procedures, the corresponding numbers were 1 (5.9%), 2 (11.7%), 7 (41.2%), and 7 (41.2%), respectively (p=0.002). Magnetic navigation in US-guided interventional procedure provides solutions in some difficult cases in which conventional US guidance is not suitable. It is especially useful in complicated interventional procedures such as ablation for liver cancer. Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramanna, L.; Tashkin, D.P.; Taplin, G.V.
1975-11-01
Seventy subjects with either no, mild, or definite evidence of pulmonary abnormality on screening studies volunteered to have detailed pulmonary function tests (PFTs), respiratory questionnaires, physical examinations, and /sup 113m/indium aerosol-inhalation lung imaging performed. Also, 22 and 52 of these subjects underwent /sup 133/xenon ventilation and lung perfusion imaging with /sup 99m/technetium-labelled macroaggregated albumin, and 56 had chest x-ray examinations performed. Results of the radionuclide lung-imaging procedures were compared with those of conventional PFTs and other clinical diagnostic procedures used to identify chronic obstructive pulmonary disease (COPD). Abnormal radioaerosol patterns were found in 32 of 33 subjects with abnormal findingsmore » on PFTs, whereas results of PFTs were abnormal in only 32 of 46 subjects with abnormal aerosol deposition. Aerosol lung images were abnormal more frequently than respiratory questionnaire responses, findings on physical examination, chest x-ray films, and perfusion lung images and with approximately the same frequency as /sup 133/xenon ventilation scintiscans. These results suggest that radioaerosol lung imaging may be a more sensitive indicator of early COPD than other diagnostic procedures, including maximal midexpiratory flow rates, single-breath nitrogen washout, and closing volume. Further studies are required to determine the physiologic and pathologic significance of isolated aerosol lung-imaging abnormalities.« less
Spitzer, Stefan Georg; Károlyi, László; Rämmler, Carola; Scharfe, Frank; Weinmann, Thomas; Zieschank, Mirko; Langbein, Anke
2017-01-01
A patient-tailored ablation approach focused on the elimination of both pulmonary vein triggers as well as substrate drivers may result in favorable outcomes in recurrent persistent AF patients. We evaluated the long-term outcomes of rotor ablation combined with conventional pulmonary vein isolation (PVI) in patients with recurrent nonparoxysmal AF. Fifty-eight consecutive patients underwent FIRM-guided rotor ablation followed by conventional PVI for the treatment of recurrent nonparoxysmal AF. A software algorithm was used to display rotational activity at rotor sites by creating propagation maps from unipolar electrograms recorded using a 64-electrode basket catheter. These rotor sites were targeted for ablation, followed by conventional PVI. All patients had nonparoxysmal AF (83% longstanding persistent) and a previously failed conventional ablation procedure. Stable rotors were identified in all patients (mean of 3.0 ± 1.6 per patient), with 55.2% having right atrial rotors and 96.6% left atrial rotors, respectively. Complications occurred in 5.2% of patients, none related to the FIRM procedure. The median follow-up was 12 months. At 6 and 12 months of follow-up, 73.2% and 76.9% of patients remained free from AF/AT, respectively. Excluding 2 patients who underwent a successful redo ablation procedure/electrical cardioversion, at 12 months of follow-up, 69.2% were free from any AF/AT and 73.1% were free from AF after a single FIRM-guided ablation procedure. A high degree of success was observed in this cohort of primarily longstanding persistent AF patients treated for recurrent AF with FIRM-guided rotor ablation. Prospective randomized controlled trials are needed. © 2016 Wiley Periodicals, Inc.
Yamaguchi, Akemi; Matsuda, Kazuyuki; Uehara, Masayuki; Honda, Takayuki; Saito, Yasunori
2016-02-04
We report a novel automated device for nucleic acid extraction, which consists of a mechanical control system and a disposable cassette. The cassette is composed of a bottle, a capillary tube, and a chamber. After sample injection in the bottle, the sample is lysed, and nucleic acids are adsorbed on the surface of magnetic silica beads. These magnetic beads are transported and are vibrated through the washing reagents in the capillary tube under the control of the mechanical control system, and thus, the nucleic acid is purified without centrifugation. The purified nucleic acid is automatically extracted in 3 min for the polymerase chain reaction (PCR). The nucleic acid extraction is dependent on the transport speed and the vibration frequency of the magnetic beads, and optimizing these two parameters provided better PCR efficiency than the conventional manual procedure. There was no difference between the detection limits of our novel device and that of the conventional manual procedure. We have already developed the droplet-PCR machine, which can amplify and detect specific nucleic acids rapidly and automatically. Connecting the droplet-PCR machine to our novel automated extraction device enables PCR analysis within 15 min, and this system can be made available as a point-of-care testing in clinics as well as general hospitals. Copyright © 2015 Elsevier B.V. All rights reserved.
Yamada, Keiko; Wanchun, Jin; Ohkura, Teruko; Murai, Atsushi; Hayakawa, Reina; Kinoshita, Keiji; Mizutani, Makoto; Okamoto, Akira; Namikawa, Takao; Ohta, Michio
2013-01-01
Immunodetection of methicillin-resistant Staphylococcus aureus (MRSA) by conventional methods employing mammalian immunoglobulins has unknown detection limits, and often yields false-positive results because of the presence of S. aureus protein A, which binds the Fc region of mammalian IgG. In this study, a new PBP2a-specific chicken IgY antibody was developed in inbred and conventional chickens, and used for the detection of MRSA using whole cell lysate samples. Our results showed that this chicken IgY antibody minimized the side effects of protein A. Moreover, enzyme-linked immunosorbent assay and immunochromatography systems were used with a monoclonal and polyclonal anti-PBP2a IgY antibody, clearly differentiating MRSA from methicillin-sensitive S. aureus and other methicillin-sensitive Staphylococcus spp. The detection limit of the immunochromatography was 10(8) colony-forming units; therefore, 1 colony on an agar plate was adequate to distinguish MRSA from non-MRSA. The specificity and sensitivity of this assay were almost similar to that of a commercially available latex agglutination test; however, the procedure used in this study was less complicated. The entire detection procedure, including sample preparation, takes only 20 min and does not require special equipment. Therefore, the use of this IgY antibody as a new tool for the detection of MRSA is highly recommended.
Bialek, Ralf; Kern, Jan; Herrmann, Tanja; Tijerina, Rolando; Ceceñas, Luis; Reischl, Udo; González, Gloria M.
2004-01-01
A conventional nested PCR and a real-time LightCycler PCR assay for detection of Coccidioides posadasii DNA were designed and tested in 120 clinical strains. These had been isolated from 114 patients within 10 years in Monterrey, Nuevo Leon, Mexico, known to be endemic for coccidioidomycosis. The gene encoding the specific antigen 2/proline-rich antigen (Ag2/PRA) was used as a target. All strains were correctly identified, whereas DNA from related members of the family Onygenaceae remained negative. Melting curve analysis by LightCycler and sequencing of the 526-bp product of the first PCR demonstrated either 100% identity to the GenBank sequence of the Silveira strain, now known to be C. posadasii (accession number AF013256), or a single silent mutation at position 1228. Length determination of two microsatellite-containing loci (GAC and 621) identified all 120 isolates as C. posadasii. Specific DNA was amplified by conventional nested PCR from three microscopically spherule-positive paraffin-embedded tissue samples, whereas 20 human tissue samples positive for other dimorphic fungi remained negative. Additionally, the safety of each step of a modified commercially available DNA extraction procedure was evaluated by using 10 strains. At least three steps of the protocol were demonstrated to sufficiently kill arthroconidia. This safe procedure is applicable to cultures and to clinical specimens. PMID:14766853
NASA Astrophysics Data System (ADS)
Firrao, D.; Begley, J. A.; Silva, G.; Roberti, R.; de Benedetti, B.
1982-06-01
Charpy-V type samples either step-quenched from 1200 °C or directly quenched from the usual 870 °C temperature, fractured by a slow bend test procedure, have been fractographically examined. Their notch root radius, ρ, ranged from almost zero (fatigue precrack) up to 2.0 mm. The fracture initiation process at the notch differs according to root radius and heat treatment. Conventionally austenitized samples with ρ values larger than 0.07 mm approximately ( ρ eff) always display a continuous shear lip formation along the notch surface, whereas specimens with smaller notches do not exhibit a similar feature. Moreover, shear lip width in specimens with ρ > ρ eff is linearly related to the applied J-integral at fracture. In high temperature austenitized samples similar shear lips are almost nonexistent. The above findings, as well as overall fractographic features, are combined to explain why blunt notch AISI 4340 steel specimens display a better fracture resistance if they are conventionally heat treated, whereas fatigue precracked samples show a superior fracture toughness when they are step-quenched from 1200 °C. Variations of fracture morphologies with the notch root radius and heat treating procedures are associated with a shift toward higher Charpy transition temperatures under the combined influence of decreasing root radii and coarsening of the prior austenitic grain size at high austenitizing temperatures.
NASA Astrophysics Data System (ADS)
Tichý, Ondřej; Šmídl, Václav; Hofman, Radek; Stohl, Andreas
2016-11-01
Estimation of pollutant releases into the atmosphere is an important problem in the environmental sciences. It is typically formalized as an inverse problem using a linear model that can explain observable quantities (e.g., concentrations or deposition values) as a product of the source-receptor sensitivity (SRS) matrix obtained from an atmospheric transport model multiplied by the unknown source-term vector. Since this problem is typically ill-posed, current state-of-the-art methods are based on regularization of the problem and solution of a formulated optimization problem. This procedure depends on manual settings of uncertainties that are often very poorly quantified, effectively making them tuning parameters. We formulate a probabilistic model, that has the same maximum likelihood solution as the conventional method using pre-specified uncertainties. Replacement of the maximum likelihood solution by full Bayesian estimation also allows estimation of all tuning parameters from the measurements. The estimation procedure is based on the variational Bayes approximation which is evaluated by an iterative algorithm. The resulting method is thus very similar to the conventional approach, but with the possibility to also estimate all tuning parameters from the observations. The proposed algorithm is tested and compared with the standard methods on data from the European Tracer Experiment (ETEX) where advantages of the new method are demonstrated. A MATLAB implementation of the proposed algorithm is available for download.
Langlois, Sylvie; Johnson, JoAnn; Audibert, François; Gekas, Jean; Forest, Jean-Claude; Caron, André; Harrington, Keli; Pastuck, Melanie; Meddour, Hasna; Tétu, Amélie; Little, Julian; Rousseau, François
2017-12-01
This study evaluates the impact of offering cell-free DNA (cfDNA) screening as a first-tier test for trisomies 21 and 18. This is a prospective study of pregnant women undergoing conventional prenatal screening who were offered cfDNA screening in the first trimester with clinical outcomes obtained on all pregnancies. A total of 1198 pregnant women were recruited. The detection rate of trisomy 21 with standard screening was 83% with a false positive rate (FPR) of 5.5% compared with 100% detection and 0% FPR for cfDNA screening. The FPR of cfDNA screening for trisomies 18 and 13 was 0.09% for each. Two percent of women underwent an invasive diagnostic procedure based on screening or ultrasound findings; without the cfDNA screening, it could have been as high as 6.8%. Amongst the 640 women with negative cfDNA results and a nuchal translucency (NT) ultrasound, only 3 had an NT greater or equal to 3.5 mm: one had a normal outcome and two lost their pregnancy before 20 weeks. cfDNA screening has the potential to be a highly effective first-tier screening approach leading to a significant reduction of invasive diagnostic procedures. For women with a negative cfDNA screening result, NT measurement has limited clinical utility. © 2017 John Wiley & Sons, Ltd.
The German Aortic Valve Registry (GARY): in-hospital outcome
Hamm, Christian W.; Möllmann, Helge; Holzhey, David; Beckmann, Andreas; Veit, Christof; Figulla, Hans-Reiner; Cremer, J.; Kuck, Karl-Heinz; Lange, Rüdiger; Zahn, Ralf; Sack, Stefan; Schuler, Gerhard; Walther, Thomas; Beyersdorf, Friedhelm; Böhm, Michael; Heusch, Gerd; Funkat, Anne-Kathrin; Meinertz, Thomas; Neumann, Till; Papoutsis, Konstantinos; Schneider, Steffen; Welz, Armin; Mohr, Friedrich W.
2014-01-01
Background Aortic stenosis is a frequent valvular disease especially in elderly patients. Catheter-based valve implantation has emerged as a valuable treatment approach for these patients being either at very high risk for conventional surgery or even deemed inoperable. The German Aortic Valve Registry (GARY) provides data on conventional and catheter-based aortic procedures on an all-comers basis. Methods and results A total of 13 860 consecutive patients undergoing repair for aortic valve disease [conventional surgery and transvascular (TV) or transapical (TA) catheter-based techniques] have been enrolled in this registry during 2011 and baseline, procedural, and outcome data have been acquired. The registry summarizes the results of 6523 conventional aortic valve replacements without (AVR) and 3464 with concomitant coronary bypass surgery (AVR + CABG) as well as 2695 TV AVI and 1181 TA interventions (TA AVI). Patients undergoing catheter-based techniques were significantly older and had higher risk profiles. The stroke rate was low in all groups with 1.3% (AVR), 1.9% (AVR + CABG), 1.7% (TV AVI), and 2.3% (TA AVI). The in-hospital mortality was 2.1% (AVR) and 4.5% (AVR + CABG) for patients undergoing conventional surgery, and 5.1% (TV AVI) and AVI 7.7% (TA AVI). Conclusion The in-hospital outcome results of this registry show that conventional surgery yields excellent results in all risk groups and that catheter-based aortic valve replacements is an alternative to conventional surgery in high risk and elderly patients. PMID:24022003
Rouchy, R C; Moreau-Gaudry, A; Chipon, E; Aubry, S; Pazart, L; Lapuyade, B; Durand, M; Hajjam, M; Pottier, S; Renard, B; Logier, R; Orry, X; Cherifi, A; Quehen, E; Kervio, G; Favelle, O; Patat, F; De Kerviler, E; Hughes, C; Medici, M; Ghelfi, J; Mounier, A; Bricault, I
2017-07-06
Interventional radiology includes a range of minimally invasive image-guided diagnostic and therapeutic procedures that have become routine clinical practice. Each procedure involves a percutaneous needle insertion, often guided using computed tomography (CT) because of its availability and usability. However, procedures remain complicated, in particular when an obstacle must be avoided, meaning that an oblique trajectory is required. Navigation systems track the operator's instruments, meaning the position and progression of the instruments are visualised in real time on the patient's images. A novel electromagnetic navigation system for CT-guided interventional procedures (IMACTIS-CT®) has been developed, and a previous clinical trial demonstrated improved needle placement accuracy in navigation-assisted procedures. In the present trial, we are evaluating the clinical benefit of the navigation system during the needle insertion step of CT-guided procedures in the thoraco-abdominal region. This study is designed as an open, multicentre, prospective, randomised, controlled interventional clinical trial and is structured as a standard two-arm, parallel-design, individually randomised trial. A maximum of 500 patients will be enrolled. In the experimental arm (navigation system), the procedures are carried out using navigation assistance, and in the active comparator arm (CT), the procedures are carried out with conventional CT guidance. The randomisation is stratified by centre and by the expected difficulty of the procedure. The primary outcome of the trial is a combined criterion to assess the safety (number of serious adverse events), efficacy (number of targets reached) and performance (number of control scans acquired) of navigation-assisted, CT-guided procedures as evaluated by a blinded radiologist and confirmed by an expert committee in case of discordance. The secondary outcomes are (1) the duration of the procedure, (2) the satisfaction of the operator and (3) the irradiation dose delivered, with (4) subgroup analysis according to the expected difficulty of the procedure, as well as an evaluation of (5) the usability of the device. This trial addresses the lack of published high-level evidence studies in which navigation-assisted CT-guided interventional procedures are evaluated. This trial is important because it addresses the problems associated with conventional CT guidance and is particularly relevant because the number of interventional radiology procedures carried out in routine clinical practice is increasing. ClinicalTrials.gov identifier: NCT01896219 . Registered on 5 July 2013.
Research Of Airborne Precision Spacing to Improve Airport Arrival Operations
NASA Technical Reports Server (NTRS)
Barmore, Bryan E.; Baxley, Brian T.; Murdoch, Jennifer L.
2011-01-01
In September 2004, the European Organization for the Safety of Air Navigation (EUROCONTROL) and the United States Federal Aviation Administration (FAA) signed a Memorandum of Cooperation to mutually develop, modify, test, and evaluate systems, procedures, facilities, and devices to meet the need for safe and efficient air navigation and air traffic control in the future. In the United States and Europe, these efforts are defined within the architectures of the Next Generation Air Transportation System (NextGen) Program and Single European Sky Air Traffic Management Research (SESAR) Program respectively. Both programs have identified Airborne Spacing as a critical component, with Automatic Dependent Surveillance Broadcast (ADS-B) as a key enabler. Increased interest in reducing airport community noise and the escalating cost of aviation fuel has led to the use of Continuous Descent Arrival (CDA) procedures to reduce noise, emissions, and fuel usage compared to current procedures. To provide these operational enhancements, arrival flight paths into terminal areas are planned around continuous vertical descents that are closer to an optimum trajectory than those in use today. The profiles are designed to be near-idle descents from cruise altitude to the Final Approach Fix (FAF) and are typically without any level segments. By staying higher and faster than conventional arrivals, CDAs also save flight time for the aircraft operator. The drawback is that the variation of optimized trajectories for different types and weights of aircraft requires the Air Traffic Controller to provide more airspace around an aircraft on a CDA than on a conventional arrival procedure. This additional space decreases the throughput rate of the destination airport. Airborne self-spacing concepts have been developed to increase the throughput at high-demand airports by managing the inter-arrival spacing to be more precise and consistent using on-board guidance. It has been proposed that the additional space needed around an aircraft performing a CDA could be reduced or eliminated when using airborne spacing techniques.
Simulation of time-control procedures for terminal area flow management
NASA Technical Reports Server (NTRS)
Alcabin, M.; Erzberger, H.; Tobias, L.; Obrien, P. J.
1985-01-01
Simulations of a terminal area traffic-management system incorporating automated scheduling and time-control (four-dimensional) techniques conducted at NASA Ames Research Center jointly with the Federal Aviation Administration, have shown that efficient procedures can be developed for handling a mix of 4D-equipped and conventionally equipped aircraft. A crucial role in this system is played by an ATC host computer algorithm, referred to as a speed advisory, that allows controllers to maintain accurate time schedules of the conventionally equipped aircraft in the traffic mix. Results are of the most recent simulations in which two important special cases were investigated. First, the effects of a speed advisory on touchdown time scheduling are examined, when unequipped aircraft are constrained to follow fuel-optimized profiles in the near-terminal area, and rescheduling procedures are developed to handle missed approaches of 4D-equipped aircraft. Various performance measures, including controller opinion, are used to evaluate the effectiveness of the procedures.
Fukuda, Haruhisa; Kuroki, Manabu
2016-03-01
To develop and internally validate a surgical site infection (SSI) prediction model for Japan. Retrospective observational cohort study. We analyzed surveillance data submitted to the Japan Nosocomial Infections Surveillance system for patients who had undergone target surgical procedures from January 1, 2010, through December 31, 2012. Logistic regression analyses were used to develop statistical models for predicting SSIs. An SSI prediction model was constructed for each of the procedure categories by statistically selecting the appropriate risk factors from among the collected surveillance data and determining their optimal categorization. Standard bootstrapping techniques were applied to assess potential overfitting. The C-index was used to compare the predictive performances of the new statistical models with those of models based on conventional risk index variables. The study sample comprised 349,987 cases from 428 participant hospitals throughout Japan, and the overall SSI incidence was 7.0%. The C-indices of the new statistical models were significantly higher than those of the conventional risk index models in 21 (67.7%) of the 31 procedure categories (P<.05). No significant overfitting was detected. Japan-specific SSI prediction models were shown to generally have higher accuracy than conventional risk index models. These new models may have applications in assessing hospital performance and identifying high-risk patients in specific procedure categories.
Khedun, S M; Naicker, T; Moodley, J
2000-05-01
To improve the diagnostic accuracy of concurrent renal disease in hypertension of pregnancy, biopsy evaluation is essential. In addition, establishing underlying renal disease is important for prognosis on future pregnancies. We therefore designed a study to determine the diagnostic yield of postpartum renal biopsy and the nature and frequency of complications associated with this procedure. Also, to determine relationships, if any, between renal function tests and ultrastructural and histopathological findings. Fifty renal biopsies were performed in the immediate postpartum period in black African women with early onset pre-eclampsia. Each biopsy specimen was placed in a separate container and coded so that sampling was unknown to the electron microscopist. Each biopsy specimen was divided into three parts, and processed and stained for light, fluorescent and transmission electron microscopy using conventional techniques. Renal tissue biopsies were adequate for diagnostic purposes in all cases. There were no complications in any of the 50 patients studied. Ultrastructural examination confirmed the light microscopy findings. In addition the ultrastructural findings showed intramembranous deposits, foot process fusion and mesangial deposits. In 16 patients with normal renal function tests; the biopsies evaluation from these patients showed ultrastructural changes. In the remaining 34 patients with abnormal renal function tests of varying severity; biopsy evaluation from these patients showed both ultrastructural and histopathological changes. Renal biopsy procedure is safe, and ultrastructural and histological findings obtained from postpartum renal biopsies are more informative than the routine renal function tests.
Secco, Gioel Gabrio; Rittger, Harald; Hoffmann, Stefan; Richardt, Gert; Abdel-Wahab, Mohamed; Reinecke, Holger; Lotan, Chaim; Werner, Gerald; Sievert, Horst; Foin, Nicolas; Di Mario, Carlo
2017-01-01
Provisional stenting of the side-branch (SB) is the universally accepted gold standard while there is still controversy on the usefulness of routine dilatation of the SB ostium. Recrossing the struts of a previously deployed stent with a wire and a balloon can prove challenging and is occasionally unsuccessful, mainly because the balloon tip hits a stent strut. This prospective multicenter international registry tested the crossing ability procedural results of a new-dedicated ultrashort balloon specifically designed for side branch dilatation (Glider, TriReme Medical, Pleasanton, CA, USA). One hundred and twenty five patients (for a total of 131 bifurcation lesions) were enrolled in the registry between January 2009 and May 2012. The Glider was used as first choice in alternative to conventional balloon (group I, 72%) or as bail-out after unsuccessful previous attempt at crossing with small conventional low-profile balloons (group II, 28%). Postprocedural coronary artery dissections and in-hospital MACE (death, myocardial infarction and repeat revascularization) were assessed. Technical success was defined as the ability of the Glider to recross the struts of a previously deployed stent while procedural success was defined as less of residual 50% diameter stenosis at the origin of the SB with a final TIMI 3 and/or freedom from in-hospital MACE. Technical success was achieved, respectively, in 92% (group I), and 83% (group II). Clinical and angiographic procedural success was achieved in 98% of the lesions. In Group II, no other balloon of the same size could cross in cases where Glider could not. A total of 13 complications were observed, including nine ostial SB dissection four of which needed a second stent on the SB, one stent loss, two severe coronary spasms, and two by thrombus formation. The unique possibility offered by this short dedicated balloon to orientate its beveled tip provides an effective strategy for recrossing stent struts when conventional low profile balloons fail achieving greater SB ostial expansion thus reducing the incidence of strut malapposition during provisional treatment of bifurcational lesions. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Moore, N. R.; Ebbeler, D. H.; Newlin, L. E.; Sutharshana, S.; Creager, M.
1992-01-01
An improved methodology for quantitatively evaluating failure risk of spaceflight systems to assess flight readiness and identify risk control measures is presented. This methodology, called Probabilistic Failure Assessment (PFA), combines operating experience from tests and flights with engineering analysis to estimate failure risk. The PFA methodology is of particular value when information on which to base an assessment of failure risk, including test experience and knowledge of parameters used in engineering analyses of failure phenomena, is expensive or difficult to acquire. The PFA methodology is a prescribed statistical structure in which engineering analysis models that characterize failure phenomena are used conjointly with uncertainties about analysis parameters and/or modeling accuracy to estimate failure probability distributions for specific failure modes. These distributions can then be modified, by means of statistical procedures of the PFA methodology, to reflect any test or flight experience. Conventional engineering analysis models currently employed for design of failure prediction are used in this methodology. The PFA methodology is described and examples of its application are presented. Conventional approaches to failure risk evaluation for spaceflight systems are discussed, and the rationale for the approach taken in the PFA methodology is presented. The statistical methods, engineering models, and computer software used in fatigue failure mode applications are thoroughly documented.
[Renal Replacement Procedure: Information, Education, Documentation].
Galle, Jan; Reitlinger, Jana
2018-06-01
In renal replacement therapy, different methods are available: hemodialysis (HD), peritoneal dialysis (PD), and kidney transplantation (KTx). In addition, variants can be used: HD as a home HD or center HD, PD as a conventional PD or automated (cycler) PD, KTx as a potentially short-term predictable living donation or conventional donor kidney donation. The patient and his familiar or caring environment must be informed accordingly. This means first of all: information about which procedures of kidney replacement therapy are possible and can be offered. Then the specific risks associated with each procedure should be elucidated (e. g. HD and shunt bleeding, PD and peritonitis, KTx and infections/neoplasias). This necessarily includes a structured documentation of the educating center/doctor about the communicated information and decisions taken. © Georg Thieme Verlag KG Stuttgart · New York.
Comparing solar energy alternatives
NASA Astrophysics Data System (ADS)
White, J. R.
1984-03-01
This paper outlines a computational procedure for comparing the merits of alternative processes to convert solar radiation to heat, electrical power, or chemical energy. The procedure uses the ratio of equipment investment to useful work as an index. Comparisons with conversion counterparts based on conventional fuels are also facilitated by examining this index. The procedure is illustrated by comparisons of (1) photovoltaic converters of differing efficiencies; (2) photovoltaic converters with and without focusing concentrators; (3) photovoltaic conversion plus electrolysis vs photocatalysis for the production of hydrogen; (4) photovoltaic conversion plus plasma arcs vs photocatalysis for nitrogen fixation. Estimates for conventionally-fuelled processes are included for comparison. The reasons why solar-based concepts fare poorly in such comparisons are traced to the low energy density of solar radiation and its low stream time factor resulting from the limited number of daylight hours available and clouds obscuring the sun.
Gehrke, Sergio Alexandre; Bettach, Raphaél; Taschieri, Silvio; Boukhris, Gilles; Corbella, Stefano; Del Fabbro, Massimo
2015-08-01
The study aims to test the hypothesis of no differences in temperature variation by using a single bur for implant site preparation as compared with conventional drilling sequence using multiple burs with incremental diameter. Synthetic blocks of bone (type I density) were used for drilling procedures. Group 1 and Group 2 - drilling with three consecutive burs for a 4.1 mm cylindrical implant and for a 4.3 mm conical implant, respectively; Group 3 - drilling with a single bur for a 4.2 mm conical implant. For each group, 20 drilling procedures were performed without irrigation and 20 with external irrigation. The temperature in the cortical bone during osteotomy for implant site preparation was measured through a thermocouple. The mean temperatures and standard deviations for the drilling without irrigation were: 25.5 ± 1.24°C for Group 1; 28.1 ± 1.76°C for Group 2; 26.5 ± 1.79°C for Group 3. Considering the drilling with irrigation, the mean values and standard deviations were: 20.4 ± 1.17°C for Group 1; 22.2 ± 1.38°C for Group 2; 20.2 ± 0.83°C for Group 3. Groups 1 and 3 yielded similar results, while Group 2 displayed significantly higher temperature increase than the other two groups. The single bur drilling protocol did not produce greater bone heating than the conventional protocol and may be considered a safe procedure. © 2013 Wiley Periodicals, Inc.
Van Bruwaene, Siska; Schijven, Marlies P; Napolitano, Daniel; De Win, Gunter; Miserez, Marc
2015-01-01
As conventional laparoscopic procedural training requires live animals or cadaver organs, virtual simulation seems an attractive alternative. Therefore, we compared the transfer of training for the laparoscopic cholecystectomy from porcine cadaver organs vs virtual simulation to surgery in a live animal model in a prospective randomized trial. After completing an intensive training in basic laparoscopic skills, 3 groups of 10 participants proceeded with no additional training (control group), 5 hours of cholecystectomy training on cadaver organs (= organ training) or proficiency-based cholecystectomy training on the LapMentor (= virtual-reality training). Participants were evaluated on time and quality during a laparoscopic cholecystectomy on a live anaesthetized pig at baseline, 1 week (= post) and 4 months (= retention) after training. All research was performed in the Center for Surgical Technologies, Leuven, Belgium. In total, 30 volunteering medical students without prior experience in laparoscopy or minimally invasive surgery from the University of Leuven (Belgium). The organ training group performed the procedure significantly faster than the virtual trainer and borderline significantly faster than control group at posttesting. Only 1 of 3 expert raters suggested significantly better quality of performance of the organ training group compared with both the other groups at posttesting (p < 0.01). There were no significant differences between groups at retention testing. The virtual trainer group did not outperform the control group at any time. For trainees who are proficient in basic laparoscopic skills, the long-term advantage of additional procedural training, especially on a virtual but also on the conventional organ training model, remains to be proven. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Dionysopoulos, Dimitrios; Strakas, Dimitrios; Koliniotou-Koumpia, Eugenia; Koumpia, Effimia
2017-07-01
The aim of this in vitro study was to evaluate the effect of using Er,Cr:YSGG laser during in-office tooth bleaching on bovine enamel surface to evaluate the safety of this therapy on tooth tissues. Thirty-six enamel specimens were prepared from bovine incisors and divided into three groups: Group 1 specimens (control) received no bleaching treatment; Group 2 received a conventional in-office bleaching treatment (40 % H 2 O 2 ); Group 3 received laser-assisted bleaching procedure (40 % H 2 O 2 ) utilizing an Er,Cr:YSGG laser. The specimens were stored for 10 days after the bleaching treatment in artificial saliva. Vickers hardness was determined using a microhardness tester, and measurements for surface roughness were done using a VSI microscope. Three specimens for each experimental group were examined under SEM and mineral composition of the specimens was evaluated using EDS. Data were statistically analyzed using one-way ANOVA, Tukey's post hoc, Wilcoxon signed rank and Kruskal-Wallis tests (a = 0.05). The Vickers hardness of the enamel was reduced after in-office bleaching procedures (p < 0.05), and changes in surface morphology of the enamel were observed. However, the surface roughness of the enamel was not influenced (p > 0.05), and no changes in mineral composition of the enamel were detected after in-office bleaching procedures (p > 0.05). The laser-assisted bleaching treatment with Er,Cr:YSGG laser did not influence the enamel surface compared to the conventional bleaching technique. The safety of the use of Er,Cr:YSGG laser during in-office tooth bleaching regarding the surface properties of the enamel was confirmed under in vitro conditions.
Vassiliou, K; Scholes, S C; Unsworth, A
2007-01-01
Total hip replacements offer relief to a great many patients every year around the world. With an expected service life of around 25 years on most devices, and with younger and younger patients undergoing this surgery, it is of great importance to understand the mechanisms of their function. Tribological testing of both conventional and hard bearing joint combinations have been conducted in many centres throughout the world, and, after being initially abandoned owing to premature failures, hard bearing combinations have been revisited as viable options for joint replacements. Improved design, manufacturing procedures, and material compositions have led to improved performance over first-generation designs in both metal-on-metal and ceramic-on-ceramic hip prostheses. This paper offers a review of the work conducted in an attempt to highlight the most important factors affecting joint performance and tribology of hard bearing combinations. The tribological performance of these joints is superior to that of conventional metal- or ceramic-on-polymer designs.
Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments.
Alapati, Satish B; Brantley, William A; Iijima, Masahiro; Clark, William A T; Kovarik, Libor; Buie, Caesar; Liu, Jie; Ben Johnson, William
2009-11-01
A novel thermomechanical processing procedure has been developed that yields a superelastic (SE) nickel-titanium (NiTi) wire (M-Wire) that laboratory testing shows has improved mechanical properties compared with conventional SE austenitic NiTi wires used for manufacture of rotary instruments. The objective of this study was to determine the origin of the improved mechanical properties. Specimens from 2 batches of M-Wire prepared under different processing conditions and from 1 batch of standard-processed SE wire for rotary instruments were examined by scanning transmission electron microscopy, temperature-modulated differential scanning calorimetry, micro-x-ray diffraction, and scanning electron microscopy with x-ray energy-dispersive spectrometric analyses. The processing for M-Wire yields a microstructure containing martensite, that the proportions of NiTi phases depend on processing conditions, and that the microstructure exhibits pronounced evidence of alloy strengthening. The presence of Ti(2)Ni precipitates in both microstructures indicates that M-Wire and the conventional SE wire for rotary instruments are titanium-rich.
Fujikawa, Takashi; Miyata, Shin-Ichi; Iwanami, Toru
2013-01-01
A phloem-limited bacterium, ‘Candidatus Liberibacter asiaticus’ (Las) is a major pathogen of citrus greening (huanglongbing), one of the most destructive citrus diseases worldwide. The rapid identification and culling of infected trees and budwoods in quarantine are the most important control measures. DNA amplification including conventional polymerase chain reaction (PCR) has commonly been used for rapid detection and identification. However, long and laborious procedures for DNA extraction have greatly reduced the applicability of this method. In this study, we found that the Las bacterial cells in the midribs of infected leaves were extracted rapidly and easily by pulverization and centrifugation with mini homogenization tubes. We also found that the Las bacterial cells in the midrib extract were suitable for highly sensitive direct PCR. The performance of direct PCR using this extraction method was not inferior to that of conventional PCR. Thus, the direct PCR method described herein is characterized by its simplicity, sensitivity, and robustness, and is applicable to quarantine testing. PMID:23437295
Mobasheri, Nasrin; Karimi, Mehrdad; Hamedi, Javad
2018-06-05
New methods to determine antimicrobial susceptibility of bacterial pathogens especially the minimum inhibitory concentration (MIC) of antibiotics have great importance in pharmaceutical industry and treatment procedures. In the present study, the MIC of several antibiotics was determined against some pathogenic bacteria using macrodilution test. In order to accelerate and increase the efficiency of culture-based method to determine antimicrobial susceptibility, the possible relationship between the changes in some physico-chemical parameters including conductivity, electrical potential difference (EPD), pH and total number of test strains was investigated during the logarithmic phase of bacterial growth in presence of antibiotics. The correlation between changes in these physico-chemical parameters and growth of bacteria was statistically evaluated using linear and non-linear regression models. Finally, the calculated MIC values in new proposed method were compared with the MIC derived from macrodilution test. The results represent significant association between the changes in EPD and pH values and growth of the tested bacteria during the exponential phase of bacterial growth. It has been assumed that the proliferation of bacteria can cause the significant changes in EPD values. The MIC values in both conventional and new method were consistent to each other. In conclusion, cost and time effective antimicrobial susceptibility test can be developed based on monitoring the changes in EPD values. The new proposed strategy also can be used in high throughput screening of biocompounds for their antimicrobial activity in a relatively shorter time (6-8 h) in comparison with the conventional methods.
Garlapati, Tejesh Gupta; Krithikadatta, Jogikalmat; Natanasabapathy, Velmurugan
2017-10-01
This in-vitro study tested the fracture resistance of endodontically treated molars with Mesial-Occluso-Distal (MOD) cavities restored with fibre reinforced composite material everX posterior in comparision with hybrid composite and ribbond fiber composite. Fifty intact freshly extracted human mandibular first molars were collected and were randomly divided into five groups (n=10). Group 1: positive control (PC) intact teeth without any endodontic preparation. In groups 2 through 6 after endodontic procedure standard MOD cavities were prepared and restored with their respective core materials as follows: group 2, negative control (NC) left unrestored or temporary flling was applied. Group 3, Hybrid composite (HC) as a core material (Te-Econom Plus Ivoclar Vivadent Asia) group 4, Ribbond (Ribbond; Seattle, WA, USA)+conventional composite resin (RCR) group 5, everX posterior (everX Posterior GC EUROPE)+conventional composite resin (EXP) after thermocycling fracture resistance for the samples were tested using universal testing machine. The results were analysed using ANOVA and Tukey's HSD post hoc tests. Mean fracture resistance (in Newton, N) was group 1: 1568.4±221.71N, group 2: 891.0±50.107N, group 3: 1418.3±168.71N, group 4:1716.7±199.51N and group 5: 1994.8±254.195N. Among the materials tested, endodontically treated teeth restored with everX posterior fiber reinforced composite showed superior fracture resistance. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Leonard, William H.
1989-01-01
Examines college students' perception of an interactive videodisc learning system as an alternative to the conventional laboratory for learning biology skills and concepts taught under classroom laboratory conditions. Reports that the videodisc instruction gave more experimental and procedural options and more efficient use of time than the…
Dong, L-R; Zhu, Y-M; Xu, Q; Cao, C-X; Zhang, B-Z
2012-01-01
This study investigated whether extraperitoneal colostomy without damaging the muscle layer of the abdominal wall is an improved surgical procedure compared with conventional sigmoid colostomy in patients undergoing abdominoperineal resection. Patients with rectal cancer undergoing abdominoperineal resection were selected and randomly divided into two groups: the study group received extraperitoneal colostomy without damaging the muscle layer of the abdominal wall and the control group received conventional colostomy. Clinical data from both groups were analysed. A total of 128 patients were included: 66 received extraperitoneal colostomy without damaging the muscle layer of the abdominal wall and 62 received conventional colostomy. Significant differences between the two groups were found in relation to colostomy operating time, defaecation sensation, bowel control and overall stoma-related complications. Duration of postoperative hospital stay was also significantly different between the study groups. Extraperitoneal colostomy without damaging the muscle layer of the abdominal wall was found to be an improved procedure compared with conventional sigmoid colostomy in abdominoperineal resection, and may reduce colostomy-related complications, shorten operating time and postoperative hospital stay, and potentially improve patients' quality of life.
Sun, F; Chen, J; Tong, Q; Zeng, S
2007-01-01
Management of drinking water safety is changing towards an integrated risk assessment and risk management approach that includes all processes in a water supply system from catchment to consumers. However, given the large number of water supply systems in China and the cost of implementing such a risk assessment procedure, there is a necessity to first conduct a strategic screening analysis at a national level. An integrated methodology of risk assessment and screening analysis is thus proposed to evaluate drinking water safety of a conventional water supply system. The violation probability, indicating drinking water safety, is estimated at different locations of a water supply system in terms of permanganate index, ammonia nitrogen, turbidity, residual chlorine and trihalomethanes. Critical parameters with respect to drinking water safety are then identified, based on which an index system is developed to prioritize conventional water supply systems in implementing a detailed risk assessment procedure. The evaluation results are represented as graphic check matrices for the concerned hazards in drinking water, from which the vulnerability of a conventional water supply system is characterized.
NASA Astrophysics Data System (ADS)
Johnson, Michael D.
1994-09-01
The impact of using the 2.1 micrometers Ho:YAG laser in orthopaedic surgery has not been fully investigated, especially as to what affect it may have on an employee's return to work and normal activities. In this retrospective review of 140 patients who underwent arthroscopic surgery at our facility, there were found to be significant decreases in time on crutches and time off from work when laser-assisted knee arthroscopies were compared to procedures where conventional mechanical or motorized instruments were used. The patients who had laser-assisted knee arthroscopies discontinued use of crutches 5 days earlier than the conventional group and returned to work 10 days earlier than their counterparts who had undergone conventional arthroscopic surgery. The ability to return to work more quickly translates into significant cost savings for employers who otherwise would have to replace the worker with temporary help, pay overtime, or face lost productivity due to an employee's absence following arthroscopic knee surgery.
NASA Astrophysics Data System (ADS)
Han, Taehee
A new technology to perform a minimally invasive cornea reshaping procedure has been developed. This can eliminate the incidence of the flap-related complications of the conventional eye refractive procedures by multiphoton processes using a very high-intensity (I ≥ 1013 W/cm 2), but low energy (Ep ˜ 100-200 microJ) femtosecond laser pulses. Due to much lower energy than that of the nanosecond laser pulses for the thermal photoablation, the multiphoton processes cause almost no collateral damage by heat and shock wave generation. In this method, a series of femtosecond laser pulses is used to create very narrow (< 30 microm) and sufficiently long (≥ 2.5 mm) micro-channels in the cornea. The micro-channels are oriented almost perpendicular to the eye's optical axis. Once the micro-channel reaches a desired length, another series of femtosecond pulses with higher intensity is efficiently delivered through the micro-channel to the endpoint where a certain amount of the stromal tissue is disintegrated by the multiphoton processes. The disintegrated fragments are ejected out of the cornea via the same micro-channel, allowing the corneal surface to collapse, and changing its refractive power. This new corneal reshaping method obviates any process of damaging the corneal surface layer, while retaining the advantages of the conventional refractive procedures such as Laser in situ keratomileusis (LASIK) and Photorefractive keratectomy (PRK). In order to demonstrate the flapless cornea reshaping procedure, we have conducted ex-vivo experiments on fresh porcine eyes. The reshaped corneas were evaluated by using optical coherence tomography (OCT). The test results have shown that this flapless intrastromal procedure can reshape the cornea as intended with almost no surface damage. We have also performed a series of experiments to demonstrate the multiphoton processes in the corneal tissue by very high-intensity femtosecond laser pulses. Through the optical emission spectroscopy, we investigated the spectral lines of calcium atom and ions from the femtosecond laser-induced plasma from the porcine corneal tissue. The experimental results have shown the intensity-dependence of ablation rate, which qualitatively verifies the characteristics of the multiphoton processes.
A computational procedure for large rotational motions in multibody dynamics
NASA Technical Reports Server (NTRS)
Park, K. C.; Chiou, J. C.
1987-01-01
A computational procedure suitable for the solution of equations of motion for multibody systems is presented. The present procedure adopts a differential partitioning of the translational motions and the rotational motions. The translational equations of motion are then treated by either a conventional explicit or an implicit direct integration method. A principle feature of this procedure is a nonlinearly implicit algorithm for updating rotations via the Euler four-parameter representation. This procedure is applied to the rolling of a sphere through a specific trajectory, which shows that it yields robust solutions.
da Costa, Márcia Gisele Santos; Santos, Marisa da Silva; Sarti, Flávia Mori; Senna, Kátia Marie Simões e.; Tura, Bernardo Rangel; Goulart, Marcelo Correia
2014-01-01
Objectives The study performs a cost-effectiveness analysis of procedures for atrial septal defects occlusion, comparing conventional surgery to septal percutaneous implant. Methods A model of analytical decision was structured with symmetric branches to estimate cost-effectiveness ratio between the procedures. The decision tree model was based on evidences gathered through meta-analysis of literature, and validated by a panel of specialists. The lower number of surgical procedures performed for atrial septal defects occlusion at each branch was considered as the effectiveness outcome. Direct medical costs and probabilities for each event were inserted in the model using data available from Brazilian public sector database system and information extracted from the literature review, using micro-costing technique. Sensitivity analysis included price variations of percutaneous implant. Results The results obtained from the decision model demonstrated that the percutaneous implant was more cost effective in cost-effectiveness analysis at a cost of US$8,936.34 with a reduction in the probability of surgery occurrence in 93% of the cases. Probability of atrial septal communication occlusion and cost of the implant are the determinant factors of cost-effectiveness ratio. Conclusions The proposal of a decision model seeks to fill a void in the academic literature. The decision model proposed includes the outcomes that present major impact in relation to the overall costs of the procedure. The atrial septal defects occlusion using percutaneous implant reduces the physical and psychological distress to the patients in relation to the conventional surgery, which represent intangible costs in the context of economic evaluation. PMID:25302806
da Costa, Márcia Gisele Santos; Santos, Marisa da Silva; Sarti, Flávia Mori; Simões e Senna, Kátia Marie; Tura, Bernardo Rangel; Correia, Marcelo Goulart; Goulart, Marcelo Correia
2014-01-01
The study performs a cost-effectiveness analysis of procedures for atrial septal defects occlusion, comparing conventional surgery to septal percutaneous implant. A model of analytical decision was structured with symmetric branches to estimate cost-effectiveness ratio between the procedures. The decision tree model was based on evidences gathered through meta-analysis of literature, and validated by a panel of specialists. The lower number of surgical procedures performed for atrial septal defects occlusion at each branch was considered as the effectiveness outcome. Direct medical costs and probabilities for each event were inserted in the model using data available from Brazilian public sector database system and information extracted from the literature review, using micro-costing technique. Sensitivity analysis included price variations of percutaneous implant. The results obtained from the decision model demonstrated that the percutaneous implant was more cost effective in cost-effectiveness analysis at a cost of US$8,936.34 with a reduction in the probability of surgery occurrence in 93% of the cases. Probability of atrial septal communication occlusion and cost of the implant are the determinant factors of cost-effectiveness ratio. The proposal of a decision model seeks to fill a void in the academic literature. The decision model proposed includes the outcomes that present major impact in relation to the overall costs of the procedure. The atrial septal defects occlusion using percutaneous implant reduces the physical and psychological distress to the patients in relation to the conventional surgery, which represent intangible costs in the context of economic evaluation.
Vorpahl, Marc; Koehler, Till; Foerst, Jason; Panagiotopoulos, Spyridon; Schleiting, Heinrich; Koss, Klaus; Ziegler, Gunda; Brinkmann, Hilmar; Seyfarth, Melchior; Tiroch, Klaus
2015-01-01
Current guidelines favor the radial approach for coronary angiography. Therefore, specialty radial diagnostic catheters were designed to engage both coronary arteries with a single device. However, it is unclear if single catheters are superior to conventional catheters. A retrospective analysis was performed of consecutive right radial coronary angiographies to determine catheter use, fluoroscopy time, radiation dosage, and consumption of contrast. Procedures were performed with a single TIG catheter or conventional catheters (CONV). Procedures with coronary artery bypass grafts or ventricular angiographies were excluded. 273 transradial procedures were performed successfully. 95 procedures were performed with CONV and 178 procedures with a TIG. Crossover to additional catheters was higher in TIG (15.2%) compared to CONV (5.3%, p = 0.02). Fluoroscopy time was comparable between CONV and TIG, without crossover (2.2 ± 1.2 min versus 2.3 ± 1.2 min; n.s.), however, greater in the case of crossover for CONV (5.8 ± 0.7) and TIG (7.6 ± 3.0; p = 0.0001). Radiation dosage was similar in CONV and the TIG, without crossover (1419 ± 1075, cGy∗cm2 versus 1690 ± 1138; n.s.), however, greater for CONV (2374 ± 620) and TIG (3733 ± 2281, p = 0.05) with crossover. Overall, the amount of contrast was greater in TIG (56 ± 13 mL) versus CONV (48 ± 3 mL; p = 0.0003). CONV femoral catheters may be the primary choice for radial approach. PMID:26435876
Hydraulic tests with direct-push equipment
Butler, J.J.; Healey, J.M.; McCall, G.W.; Garnett, E.J.; Loheide, Steven P.
2002-01-01
The potential of direct-push technology for hydraulic characterization of saturated flow systems was investigated at a field site with a considerable degree of subsurface control. Direct-push installations were emplaced by attaching short lengths of screen (shielded and unshielded) to the bottom end of a tool string that was then advanced into the unconsolidated sediments. A series of constant-rate pumping tests were performed in a coarse sand and gravel aquifer using direct-push tool strings as observation wells. Very good agreement (within 4%) was found between hydraulic conductivity (K) estimates from direct-push installations and those from conventional wells. A program of slug tests was performed in direct-push installations using small-diameter adaptations of solid-slug and pneumatic methods. In a sandy silt interval of moderate hydraulic conductivity, K values from tests in a shielded screen tool were in excellent agreement (within 2%) with those from tests in a nearby well. In the coarse sand and gravel aquifer, K values were within 12% of those from multilevel slug tests at a nearby well. However, in the more permeable portions of the aquifer (K > 70 m/day), the smaller-diameter direct-push rods (0.016 m inner diameter [I.D.]) attenuated test responses, leading to an underprediction of K. In those conditions, use of larger-diameter rods (e.g., 0.038 m I.D.) is necessary to obtain K values representative of the formation. This investigation demonstrates that much valuable information can be obtained from hydraulic tests in direct-push installations. As with any type of hydraulic test, K estimates are critically dependent on use of appropriate emplacement and development procedures. In particular, driving an unshielded screen through a heterogeneous sequence will often lead to a buildup of low-K material that can be difficult to remove with standard development procedures.
Lin, Tseng-Kai; Su, Jin-Tsung; Lee, Fa-Kung; Lin, Yu-Ru; Lo, Hsiao-Ching
2010-09-01
This study was conducted to compare the efficacy of cryotop vitrification of human cleavage-stage embryos to that of conventional slow freezing of these embryos with respect to survival. A second objective was to compare the two cryopreservation techniques with respect to outcomes for a cohort of women. Cleavage-stage embryos from 102 patients were cryopreserved either by vitrification (57 patients) or by traditional slow freezing (45 patients). After thawing, rates of embryo survival, implantation, and clinical pregnancy were determined. Survival of embryos was significantly higher with the vitrification procedure as compared to traditional slow freezing [287/298 (96.3%) vs. 294/446 (65.9%); p < 0.05). Rates of implantation and clinical pregnancy were also significantly higher using vitrification procedure as compared to the slow freezing procedure (24.3% vs. 7.1% and 35.6% vs. 15.6% respectively, p < 0.05). As compared to conventional slow freezing, cryopreservation of human cleavage-stage embryo using vitrification results in higher rates of embryo survival, implantation, and clinical pregnancy. Vitrification therefore represents the superior cryopreservation technique for cleavage-stage embryos. Copyright © 2010 Taiwan Association of Obstetric & Gynecology. Published by Elsevier B.V. All rights reserved.
The Design and its Verification of the Double Rotor Double Cage Induction Motor
NASA Astrophysics Data System (ADS)
Sinha, Sumita; Deb, Nirmal K.; Biswas, Sujit K.
2017-02-01
The concept of a double rotor motor presented earlier and its equivalent circuit has been developed, showing a non-linear parameter content. The two rotors (which are recommended to be double cage type for development of high starting torque) can run with equal or unequal speed independently, depending on their individual loading. This paper presents the elaborate design procedure, step-by-step, for the double rotor double cage motor and verifies the designed data with that obtained from three separate tests (compared to two for conventional motor) on a prototype, such that optimum performance can be obtained from the motor.
de Araújo, Felipe Brandão Corrêa; Starling, Eduardo Simão; Maricevich, Marco; Tobias-Machado, Marcos
2014-10-01
To demonstrate the feasibility of endoscopic extraperitoneal single site (EESS) inguinal hernia repair and compare it outcomes with the conventional totally extraperitoneal (TEP) technique. TEP inguinal hernia repair is a widely accepted alternative to conventional open technique with several perioperative advantages. Transumbilical laparoendoscopic singlesite surgery (LESS) is an emerging approach and has been reported for a number of surgical procedures with superior aesthetic results but other advantages need to be proven. Thirty-eight uncomplicated inguinal hernias were repaired by EESS approach between January 2010 and January 2011. All procedures were performed through a 25 cm infraumbilical incision using the Alexis wound retractor attached to a surgical glove and three trocars. Body mass index, age, operative time, blood loss, complications, conversion rate, analgesia requirement, hospital stay, return to normal activities and patient satisfaction with aesthetic results were analysed and compared with the last 38 matched-pair group of patients who underwent a conventional TEP inguinal hernia repair by the same surgeon. All procedures were performed successfully with no conversion. In both unilateral and bilateral EESS inguinal repairs, the mean operative time was longer than conventional TEP (55± 20 vs. 40± 15 min, P = 0.049 and 70± 15 vs. 55± 10 min, P = 0.014). Aesthetic result was superior in the EESS group (2.88± 0.43 vs. 2.79± 0.51, P = 0.042). There was no difference between the two approaches regarding blood loss, complications, hospital stay, time until returns to normal activities and analgesic requirement. EESS inguinal hernia repair is safe and effective, with superior cosmetic results in the treatment of uncomplicated inguinal hernias. Other advantages of this new technique still need to be proven.
Donor cross-linking for keratoplasty: a laboratory evaluation.
Mukherjee, Achyut; Hayes, Sally; Aslanides, Ioannis; Lanchares, Elena; Meek, Keith M
2015-12-01
This laboratory-based investigation compares the topographic outcomes of conventional penetrating keratoplasty with that of a novel procedure in which donor corneas are cross-linked prior to keratoplasty. Penetrating keratoplasty procedures with continuous running sutures were carried out in a porcine whole globe model. Sixty eyes were randomly paired as 'donor' and 'host' tissue before being assigned to one of two groups. In the cross-linked group, donor corneas underwent riboflavin/UVA cross-linking prior to being trephined and sutured to untreated hosts. In the conventional keratoplasty group, both host and donor corneas remained untreated prior to keratoplasty. Topographic and corneal wavefront measurements were performed following surgery, and technical aspects of the procedure evaluated. Mean keratometric astigmatism was significantly lower in the cross-linked donor group at 3.67D (SD 1.8 D), vs. 8.43 D (SD 2.4 D) in the conventional keratoplasty group (p < 0.005). Mean wavefront astigmatism was also significantly reduced in the cross-linked donor group 4.71 D (SD 2.1) vs. 8.29D (SD 3.6) in the conventional keratoplasty group (p < 0.005). Mean RMS higher order aberration was significantly lower in the cross-linked donor group at 1.79 um (SD 0.98), vs. 3.05 um (SD 1.9) in the conventional keratoplasty group (P = 0.02). Qualitative analysis revealed less tissue distortion at the graft-host junction in the cross-linked group. Cross-linking of donor corneas prior to keratoplasty reduces intraoperative induced astigmatism and aberrations in an animal model. Further studies are indicated to evaluate the implications of this potential modification of keratoplasty surgery.
Ship recycling and marine pollution.
Chang, Yen-Chiang; Wang, Nannan; Durak, Onur Sabri
2010-09-01
This paper discusses the historical background, structure and enforcement of the '2009 Hong Kong International Convention on the Safe and Environmentally Sound Recycling of Ships.' the 2009 Hong Kong Convention establishes control and enforcement instruments related to ship recycling, determining the control rights of Port States and the obligations of Flag States, Parties and recycling facilities under its jurisdiction. The Convention also controls the communication and exchange of information procedures, establishes a reporting system to be used upon the completion of recycling, and outlines an auditing system for detecting violations. The Convention, however, also contains some deficiencies. This paper concludes these deficiencies will eventually influence the final acceptance of this Convention by the international community. Copyright 2010 Elsevier Ltd. All rights reserved.
Huo, Yan; Hindricks, Gerhard; Piorkowski, Christopher; Bollmann, Andreas; Wetzel, Ulrike; Sommer, Phillip; Gaspar, Thomas; Kottkamp, Hans; Arya, Arash
2010-06-01
The objective of this study was to compare results between the magnetic navigation system (MNS) and conventional catheter ablation of cavo-tricuspid isthmus (CTI)-dependent right atrial flutter (AFL) in a case control study. A remote MNS has been used for ablation of various arrhythmias including CTI-dependent AFL but comparative results between MNS and conventional ablation are not available. Between May and September 2007, a total of 51 consecutive patients (45 men, mean age 65.4 +/- 9.4 years) had undergone catheter ablation for CTI-dependent AFL. The catheter ablation (70 degrees C, 70 W, 90 s) was performed with either an 8-mm-tip magnetic catheter using MNS (case group, n = 26, 23 men, mean age 64.6 +/- 9.6 y) or a conventional 8-mm catheter (case group, n = 25, 22 men, mean age 65.4 +/- 9.1 y). Acute procedural success was defined as complete bidirectional isthmus block and success at six months was defined as absence of AFL during the six months follow-up. With respect to baseline characteristics there were no differences between the two groups. The procedure time in MNS and conventional group was [median (range)] 53 (30-130) min and 45 (30-100) min, respectively (P = 0.12). Acute success was achieved by MNS and conventional ablation in 25/26 (96.2%) and 25/25 (100%) of patients, respectively (P = 0.53). During the six months of follow-up 4 patients, 2 in each group, experienced recurrence (P = 0.90). No major complication occurred during the procedure. Charring on the catheter tip occurred in 5 patients (19.2%) in MNS and none of the patients in the control group (P <0.05). This case-control study demonstrated the acute and mid-term efficacy and safety of catheter ablation by MNS for CTI-dependent AFL, similar to rates achieved by conventional radiofrequency catheter ablation.
Descent Advisor Preliminary Field Test
NASA Technical Reports Server (NTRS)
Green, Steven M.; Vivona, Robert A.; Sanford, Beverly
1995-01-01
A field test of the Descent Advisor (DA) automation tool was conducted at the Denver Air Route Traffic Control Center in September 1994. DA is being developed to assist Center controllers in the efficient management and control of arrival traffic. DA generates advisories, based on trajectory predictions, to achieve accurate meter-fix arrival times in a fuel efficient manner while assisting the controller with the prediction and resolution of potential conflicts. The test objectives were: (1) to evaluate the accuracy of DA trajectory predictions for conventional and flight-management system equipped jet transports, (2) to identify significant sources of trajectory prediction error, and (3) to investigate procedural and training issues (both air and ground) associated with DA operations. Various commercial aircraft (97 flights total) and a Boeing 737-100 research aircraft participated in the test. Preliminary results from the primary test set of 24 commercial flights indicate a mean DA arrival time prediction error of 2.4 seconds late with a standard deviation of 13.1 seconds. This paper describes the field test and presents preliminary results for the commercial flights.
NASA Technical Reports Server (NTRS)
Strout, F. G.
1976-01-01
A JT8D-17 turbofan engine was tested in the NASA-Ames 40- by 80-foot wind tunnel to determine flight effects on jet and fan noise. Baseline, quiet nacelle with 20-lobe ejector/suppressor, and internal mixer configurations were tested over a range of engine power settings and tunnel velocities. Flight effects derived from the 40- by 80-foot wind tunnel test are compared with 727/JT8D flight test data and with model data obtained in a smaller wind tunnel. Procedures are defined for measuring noise data in a wind tunnel relatively near the sources and analyzing the results to obtain far-field flight effects. Wind tunnel and 727 flight test noise results compare favorably for both the baseline and quiet nacelle configurations. Two reports are provided, including a comprehensive version with extensive test results and analysis and the subject summary version that emphasizes data analysis and program finding.
Multipath interference test method for distributed amplifiers
NASA Astrophysics Data System (ADS)
Okada, Takahiro; Aida, Kazuo
2005-12-01
A method for testing distributed amplifiers is presented; the multipath interference (MPI) is detected as a beat spectrum between the multipath signal and the direct signal using a binary frequency shifted keying (FSK) test signal. The lightwave source is composed of a DFB-LD that is directly modulated by a pulse stream passing through an equalizer, and emits the FSK signal of the frequency deviation of about 430MHz at repetition rate of 80-100 kHz. The receiver consists of a photo-diode and an electrical spectrum analyzer (ESA). The base-band power spectrum peak appeared at the frequency of the FSK frequency deviation can be converted to amount of MPI using a calibration chart. The test method has improved the minimum detectable MPI as low as -70 dB, compared to that of -50 dB of the conventional test method. The detailed design and performance of the proposed method are discussed, including the MPI simulator for calibration procedure, computer simulations for evaluating the error caused by the FSK repetition rate and the fiber length under test and experiments on singlemode fibers and distributed Raman amplifier.
Early diagnostic of concurrent gear degradation processes progressing under time-varying loads
NASA Astrophysics Data System (ADS)
Guilbault, Raynald; Lalonde, Sébastien
2016-08-01
This study develops a gear diagnostic procedure for the detection of multi- and concurrent degradation processes evolving under time-varying loads. Instead of a conventional comparison between a descriptor and an alarm level, this procedure bases its detection strategy on a descriptor evolution tracking; a lasting descriptor increase denotes the presence of ongoing degradation mechanisms. The procedure works from time domain residual signals prepared in the frequency domain, and accepts any gear conditions as reference signature. To extract the load fluctuation repercussions, the procedure integrates a scaling factor. The investigation first examines a simplification assuming a linear connection between the load and the dynamic response amplitudes. However, while generally valuable, the precision losses associated with large load variations may mask the contribution of tiny flaws. To better reflect the real non-linear relation, the paper reformulates the scaling factor; a power law with an exponent value of 0.85 produces noticeable improvements of the load effect extraction. To reduce the consequences of remaining oscillations, the procedure also includes a filtering phase. During the validation program, a synthetic wear progression assuming a commensurate relation between the wear depth and friction assured controlled evolutions of the surface degradation influence, whereas the fillet crack growth remained entirely determined by the operation conditions. Globally, the tested conditions attest that the final strategy provides accurate monitoring of coexisting isolated damages and general surface deterioration, and that its tracking-detection capacities are unaffected by severe time variations of external loads. The procedure promptly detects the presence of evolving abnormal phenomena. The tests show that the descriptor curve shapes virtually describe the constant wear progression superimposed on the crack length evolution. At the tooth fracture, the mean values of the residual signal evince strong perturbations, while after this episode, the monitoring curves continue signaling the ongoing wear process.
Evans, Heather L; O'Shea, Dylan J; Morris, Amy E; Keys, Kari A; Wright, Andrew S; Schaad, Douglas C; Ilgen, Jonathan S
2016-02-01
This pilot study assessed the feasibility of using first person (1P) video recording with Google Glass (GG) to assess procedural skills, as compared with traditional third person (3P) video. We hypothesized that raters reviewing 1P videos would visualize more procedural steps with greater inter-rater reliability than 3P rating vantages. Seven subjects performed simulated internal jugular catheter insertions. Procedures were recorded by both Google Glass and an observer's head-mounted camera. Videos were assessed by 3 expert raters using a task-specific checklist (CL) and both an additive- and summative-global rating scale (GRS). Mean scores were compared by t-tests. Inter-rater reliabilities were calculated using intraclass correlation coefficients. The 1P vantage was associated with a significantly higher mean CL score than the 3P vantage (7.9 vs 6.9, P = .02). Mean GRS scores were not significantly different. Mean inter-rater reliabilities for the CL, additive-GRS, and summative-GRS were similar between vantages. 1P vantage recordings may improve visualization of tasks for behaviorally anchored instruments (eg, CLs), whereas maintaining similar global ratings and inter-rater reliability when compared with conventional 3P vantage recordings. Copyright © 2016 Elsevier Inc. All rights reserved.
Hernán Ocaña, Pablo
2018-04-01
Currently, sedation in endoscopic procedures is considered a necessary condition and a criterion of quality in digestive endoscopy. The role of SAE in conventional endoscopic procedures is clearly established in clinical guidelines, but this is not so clear in complex endoscopic procedures, such as ERCP. In recent years, numerous studies have been published, with results similar to those noticed in this article, endorsing the safety, efficacy and efficiency of SAE, when performed by properly trained staff.
Permanent Leadless Cardiac Pacemaker Therapy: A Comprehensive Review.
Tjong, Fleur V Y; Reddy, Vivek Y
2017-04-11
A new technology, leadless pacemaker therapy, was recently introduced clinically to address lead- and pocket-related complications in conventional transvenous pacemaker therapy. These leadless devices are self-contained right ventricular single-chamber pacemakers implanted by using a femoral percutaneous approach. In this review of available clinical data on leadless pacemakers, early results with leadless devices are compared with historical results with conventional single-chamber pacing. Both presently manufactured leadless pacemakers show similar complications, which are mostly related to the implant procedure: cardiac perforation, device dislocation, and femoral vascular access site complications. In comparison with conventional transvenous single-chamber pacemakers, slightly higher short-term complication rates have been observed: 4.8% for leadless pacemakers versus 4.1% for conventional pacemakers. The complication rate of the leadless pacemakers is influenced by the implanter learning curve for this new procedure. No long-term outcome data are yet available for the leadless pacemakers. Larger leadless pacing trials, with long-term follow-up and direct randomized comparison with conventional pacing systems, will be required to define the proper clinical role of these leadless systems. Although current leadless pacemakers are limited to right ventricular pacing, future advanced, communicating, multicomponent systems are expected to expand the potential benefits of leadless therapy to a larger patient population. © 2017 American Heart Association, Inc.
Class Identification Efficacy in Piecewise GMM with Unknown Turning Points
ERIC Educational Resources Information Center
Ning, Ling; Luo, Wen
2018-01-01
Piecewise GMM with unknown turning points is a new procedure to investigate heterogeneous subpopulations' growth trajectories consisting of distinct developmental phases. Unlike the conventional PGMM, which relies on theory or experiment design to specify turning points a priori, the new procedure allows for an optimal location of turning points…
24 CFR 51.206 - Implementation.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Conventional Fuels or Chemicals of an Explosive or Flammable Nature § 51.206 Implementation. This subpart C... entity responsible for review of the project. The implementation procedure will be part of the environmental review process in accordance with the procedures set forth in 24 CFR parts 50 and 58. [61 FR 13334...
24 CFR 51.206 - Implementation.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Conventional Fuels or Chemicals of an Explosive or Flammable Nature § 51.206 Implementation. This subpart C... entity responsible for review of the project. The implementation procedure will be part of the environmental review process in accordance with the procedures set forth in 24 CFR parts 50 and 58. [61 FR 13334...
24 CFR 51.206 - Implementation.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Conventional Fuels or Chemicals of an Explosive or Flammable Nature § 51.206 Implementation. This subpart C... entity responsible for review of the project. The implementation procedure will be part of the environmental review process in accordance with the procedures set forth in 24 CFR parts 50 and 58. [61 FR 13334...
24 CFR 51.206 - Implementation.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Conventional Fuels or Chemicals of an Explosive or Flammable Nature § 51.206 Implementation. This subpart C... entity responsible for review of the project. The implementation procedure will be part of the environmental review process in accordance with the procedures set forth in 24 CFR parts 50 and 58. [61 FR 13334...
24 CFR 51.206 - Implementation.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Conventional Fuels or Chemicals of an Explosive or Flammable Nature § 51.206 Implementation. This subpart C... entity responsible for review of the project. The implementation procedure will be part of the environmental review process in accordance with the procedures set forth in 24 CFR parts 50 and 58. [61 FR 13334...
Novel Hybrid Operating Table for Neuroendovascular Treatment.
Jong-Hyun, Park; Jonghyeon, Mun; Dong-Seung, Shin; Bum-Tae, Kim
2017-03-25
The integration of interventional and surgical techniques is requiring the development of a new working environment equipped for the needs of an interdisciplinary neurovascular team. However, conventional surgical and interventional tables have only a limited ability to provide for these needs. We have developed a concept mobile hybrid operating table that provides the ability for such a team to conduct both endovascular and surgical procedures in a single session. We developed methods that provide surgeons with angiography-guided surgery techniques for use in a conventional operating room environment. In order to design a convenient device ideal for practical use, we consulted with mechanical engineers. The mobile hybrid operating table consists of two modules: a floating tabletop and a mobile module. In brief, the basic principle of the mobile hybrid operating table is as follows: firstly, the length of the mobile hybrid operating table is longer than that of a conventional surgical table and yet shorter than a conventional interventional table. It was designed with the goal of exhaustively meeting the intensive requirements of both endovascular and surgical procedures. Its mobile module allows for the floating tabletop to be moved quickly and precisely. It is important that during a procedure, a patient can be moved without being repositioned, particularly with a catheter in situ. Secondly, a slim-profile headrest facilitates the mounting of a radiolucent head cramp system for cranial stabilization and fixation. We have introduced a novel invention, a mobile hybrid operating table for use in an operating suite.
Males, J J; Viswanathan, D
2018-01-01
PurposeTo compare the long-term outcomes of accelerated corneal collagen crosslinking (CXL) to conventional CXL for progressive keratoconus.Patients and methodsComparative clinical study of consecutive progressive keratoconic eyes that underwent either accelerated CXL (9 mW/cm 2 ultraviolet A (UVA) light irradiance for 10 min) or conventional CXL (3 mW/cm 2 UVA light irradiance for 30 min). Eyes with minimum 12 months' follow-up were included. Post-procedure changes in keratometry readings (Flat meridian: K1; steep meridian: K2), central corneal thickness (CCT), best spectacle-corrected visual acuity (BSCVA), and manifest refraction spherical equivalent (MRSE) were analysed.ResultsA total of 42 eyes were included. In all, 21 eyes had accelerated CXL (20.5±5.5 months' follow-up) and 21 eyes had conventional CXL group (20.2±5.6 months' follow-up). In the accelerated CXL group, a significant reduction in K2 (P=0.02), however no significant change in K1 (P=0.35) and CCT (P=0.62) was noted. In the conventional CXL group, a significant reduction was seen in K1 (P=0.01) and K2 (P=0.04), but not in CCT (P=0.95). Although both groups exhibited significant reductions in K2 readings, no noteworthy differences were noted between them (P=0.36). Improvements in BSCVA (accelerated CXL; P=0.22 and conventional CXL; P=0.20) and MRSE (accelerated CXL; P=0.97 and conventional CXL; P=0.54) were noted, however were not significant in either group.ConclusionAccelerated and conventional CXL appear to be effective procedures for stabilising progressive keratoconus in the long-term.
Conradi, Lenard; Kloth, Benjamin; Seiffert, Moritz; Schirmer, Johannes; Koschyk, Dietmar; Blankenberg, Stefan; Reichenspurner, Hermann; Diemert, Patrick; Treede, Hendrik
2014-12-01
Recently, the feasibility of valve-in-valve procedures using current first-generation transcatheter heart valves (THV) in cases of structural valve degeneration has been reported as an alternative to conventional open repeat valve replacement. By design, certain biological valve xenografts carry a high risk of coronary ostia occlusion due to lateral displacement of leaflets after valve-in-valve procedures. In the present report we aimed to prove feasibility and safety of transapical valve-in-valve implantation of the JenaValve THV in two cases of degenerated Mitroflow bioprostheses. We herein report two cases of successful transapical valve-in-valve procedures using a JenaValve THV implanted in Sorin Mitroflow bioprostheses for structural valve degeneration. Both patients were alive and in good clinical condition at 30 days from the procedure. However, increased transvalvular gradients were noted in both cases. Transcatheter valve-in-valve implantation of a JenaValve THV is a valid alternative for patients with degenerated Mitroflow bioprostheses of sufficient size and in the presence of short distances to the coronary ostia who are too ill for conventional repeat open heart surgery. Increased pressure gradients have to be expected and weighed against the disadvantages of other treatment options when planning such a procedure.
Introducing genetic testing for cardiovascular disease in primary care: a qualitative study.
Middlemass, Jo B; Yazdani, Momina F; Kai, Joe; Standen, Penelope J; Qureshi, Nadeem
2014-05-01
While primary care systematically offers conventional cardiovascular risk assessment, genetic tests for coronary heart disease (CHD) are increasingly commercially available to patients. It is unclear how individuals may respond to these new sources of risk information. To explore how patients who have had a recent conventional cardiovascular risk assessment, perceive additional information from genetic testing for CHD. Qualitative interview study in 12 practices in Nottinghamshire from both urban and rural settings. Interviews were conducted with 29 adults, who consented to genetic testing after having had a conventional cardiovascular risk assessment. Individuals' principal motivation for genetic testing was their family history of CHD and a desire to convey the results to their children. After testing, however, there was limited recall of genetic test results and scepticism about the value of informing their children. Participants dealt with conflicting findings from the genetic test, family history, and conventional assessment by either focusing on genetic risk or environmental lifestyle factors. In some participants, genetic test results appeared to reinforce healthy behaviour but others were falsely reassured, despite having an 'above-average' conventional cardiovascular risk score. Although genetic testing was acceptable, participants were unclear how to interpret genetic risk results. To facilitate healthy behaviour, health professionals should explore patients' understanding of genetic test results in light of their family history and conventional risk assessment.
Bansal, Neha; Saha, Sonali; Jaiswal, Jn; Samadi, Firoza
2014-05-01
The present study was taken up to clinically evaluate and compare effectiveness of transcutaneous electrical nerve stimulator (TENS) and comfort control syringe (CCS) in various pediatric dental procedures as an alternative to the conventional method of local anesthesia (LA) administration. Ninety healthy children having at least one deciduous molar tooth indicated for extraction in either maxillary right or left quadrant in age group of 6 to 10 years were randomly divided into three equal groups having 30 subjects each. Group I: LA administration using conventional syringe, group II: LA administration using TENS along with the conventional syringe, group III: LA administration using CCS. After LA by the three techniques, pain, anxiety and heart rate were measured. The observations, thus, obtained were subjected to statistical analysis using analysis of variance (ANOVA), student t-test and paired t-test. The mean pain score was maximum in group I followed by group II, while group III revealed the minimum pain, where LA was administered using CCS. Mean anxiety score was maximum in group I followed by group II, while group III revealed the minimum score. Mean heart rate was maximum in group I followed in descending order by groups II and III. The study supports the belief that CCS could be a viable alternative in comparison to the other two methods of LA delivery in children. How to cite this article: Bansal N, Saha S, Jaiswal JN, Samadi F. Pain Elimination during Injection with Newer Electronic Devices: A Comparative Evaluation in Children. Int J Clin Pediatr Dent 2014;7(2):71-76.
Lifting and protecting residential structures from subsidence damage using airbags
DOE Office of Scientific and Technical Information (OSTI.GOV)
Triplett, T.L.; Bennett, R.M.
1998-12-31
Conventional practice in protecting residential structures from subsidence damage concentrates on saving the superstructure. The foundation is sacrificed, even though it represents the structural component with the greatest replacement cost. In this study, airbags were used to lift a 20 ft x 30 ft structure to test their ability to protect both the foundation and superstructure from ground settlement. Two contiguous sides of the test foundation were unreinforced, and the other two contiguous sides incorporated footing and wall reinforcement. The airbags successfully lifted the structure without causing damage, even on the unreinforced sides. This paper gives a procedure for determiningmore » airbag spacing, and describes installation and operation techniques of the airbags. The paper then focuses on the performance of the airbags in lifting the structure, and shows that airbags can preserve existing foundations during subsidence movements.« less
Badalament, R A; Fair, W R; Whitmore, W F; Melamed, M R
1988-02-01
The flow cytometric studies presented herein are based almost entirely on DNA measurements and represent an early application of this diagnostic test. Nevertheless, the MSKCC experience with FCM has demonstrated that it is technically feasible and clinically useful. The sensitivity of FCM is in the range of 80% to 85% overall, and is superior to that of conventional voided or bladder wash cytology. In the absence of inflammation secondary to infection, calculi, or intravesical agents such as BCG, the specificity is greater than 90%. In the presence of inflammation, FCM appears to be less specific than conventional cytology. A potential advantage of FCM over cytology is the quantitative nature of the examination permitting comparisons of sequential examinations. Also, there are refinements in technique that hold promise of increasing the accuracy or clinical usefulness of FCM, eg, the joint measurements of DNA and differentiation antigens defined by monoclonal antibodies. Yet, despite the current and potential advantages of FCM, voided urinary cytology continues to be the procedure of choice for detection and monitoring urothelial carcinoma, not only because of our long experience and better understanding of this test, but because of its proven high specificity, because it is noninvasive, widely available, and may help to detect upper tract or urethral tumors.
NDE of hybrid armor structures using acoustography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandhu, Jaswinder S.; Pergantis, Charles G.
2011-06-23
The US Army is investigating the use of composite materials to deliver lightweight and more effective armor protection systems to soldiers and other army assets. However, widespread use of such hybrid armor will require a reliable but fast NDE methodology to ensure integrity of these components during manufacturing and while in service. Traditional ultrasonic inspection of such hybrid armor structures may prove to be very effective, but point-by-point ultrasonic scanning is inherently time-consuming and manufacturing slowdowns could develop in high-volume production of such armor systems. In this paper, we report on the application of acoustography for the NDE of hybridmore » armor structures. Acoustography differs from conventional ultrasonic testing in that test objects are inspected in full field, analogously to real time x-ray imaging. The approach uses a novel, super high resolution large area acousto-optic (AO) sensor, which allows image formation through simple ultrasound shadow casting, analogous to x-ray image formation. This NDE approach offers significant inspection speed advantage over conventional point-by-point ultrasonic scanning procedures and is well-suited for high volume production. We will report initial results on a number of hybrid armor plate specimens employing composite materials that are being investigated by the US Army. Acoustography NDE results will also be verified using other complimentary NDE methods.« less
Bayesian adaptive phase II screening design for combination trials
Cai, Chunyan; Yuan, Ying; Johnson, Valen E
2013-01-01
Background Trials of combination therapies for the treatment of cancer are playing an increasingly important role in the battle against this disease. To more efficiently handle the large number of combination therapies that must be tested, we propose a novel Bayesian phase II adaptive screening design to simultaneously select among possible treatment combinations involving multiple agents. Methods Our design is based on formulating the selection procedure as a Bayesian hypothesis testing problem in which the superiority of each treatment combination is equated to a single hypothesis. During the trial conduct, we use the current values of the posterior probabilities of all hypotheses to adaptively allocate patients to treatment combinations. Results Simulation studies show that the proposed design substantially outperforms the conventional multiarm balanced factorial trial design. The proposed design yields a significantly higher probability for selecting the best treatment while allocating substantially more patients to efficacious treatments. Limitations The proposed design is most appropriate for the trials combining multiple agents and screening out the efficacious combination to be further investigated. Conclusions The proposed Bayesian adaptive phase II screening design substantially outperformed the conventional complete factorial design. Our design allocates more patients to better treatments while providing higher power to identify the best treatment at the end of the trial. PMID:23359875
Yuenyongviwat, Varah; Tuntarattanapong, Pakjai; Tangtrakulwanich, Boonsin
2016-01-11
Internal fixation is one treatment for femoral neck fracture. Some devices and techniques reported improved accuracy and decreased fluoroscopic time. However, these are not widely used nowadays due to the lack of available special instruments and techniques. To improve the surgical procedure, the authors designed a new adjustable drill guide and tested the efficacy of the device. The authors developed a new adjustable drill guide for cannulated screw guide wire insertion for multiple screw fixation. Eight orthopaedic surgeons performed the experimental study to evaluate the efficacy of this device. Each surgeon performed guide wire insertion for multiple screw fixation in six synthetic femurs: three times with the new device and three times with the conventional technique. The fluoroscopic time, operative time and surgeon satisfaction were evaluated. In the operations with the new adjustable drill guide, the fluoroscopic and operative times were significantly lower than the operations with the conventional technique (p < 0.05). The mean score for the level of satisfaction of this device was also statistically significantly better (p = 0.02) than the conventional technique. The fluoroscopic and operative times with the new adjustable drill guide were reduced for multiple screw fixation of femoral neck fracture and the satisfaction of the surgeons was good.
Payne, Gemma; Reedy, Brian; Lennard, Chris; Comber, Bruce; Exline, David; Roux, Claude
2005-05-28
This study investigated the application of chemical imaging to the detection of latent fingerprints using the Condor macroscopic chemical imaging system (ChemImage Corp., Pittsburgh, USA). Methods were developed and optimised for the visualisation of untreated latent fingerprints and fingerprints processed with DFO, ninhydrin, cyanoacrylate, and cyanoacrylate plus rhodamine 6G stain. The results obtained with chemical imaging were compared to the detection achieved using conventional imaging techniques. The Condor significantly improved the detection of many prints, especially those that might be considered poor quality or borderline prints. Prints on newspaper treated with ninhydrin and DFO, and prints on white and yellow paper treated with ninhydrin, benefited the most from chemical imaging detection. In many cases, fingerprints undetectable using conventional imaging techniques could be visualised with chemical imaging. Ridge detail from untreated prints on yellow paper was also detected using the Condor. When prints of high quality were examined, both detection techniques produced quality results. The results of this project demonstrate that chemical imaging offers advantages over conventional visualisation techniques when examining latent fingerprints, especially those that would be considered difficult, such as weak prints or prints on surfaces that produce highly luminescent backgrounds. Standard testing procedures for the detection and enhancement of fingerprints by chemical imaging are presented and discussed.
Pappalardo, Sabrina; Guarnieri, Renzo
2014-07-01
The aim of the present study is to compare piezoelectric surgery to the conventional rotatory surgery in mandibular cyst enucleation, and to determine the 2 method's suitability and the postoperative outcomes. Eighty patients were included in the study. 35 male and 45 female, which showed cystic mandibular lesions, compared with the inferior alveolar nerve or the mental nerve. The patients were randomly divided into two groups. In the test group, cystectomy was performed using conventional rotatory instrumentation (rotatory-group), and in the other one piezoelectric surgery (piezo-group). The swelling was documented 24/48/72 h and 1 week post-surgery and the patients recorded their subjective postoperative pain daily for 7 days using a Visual Analog Scale (VAS). Patients treated with piezoelectric technique have presented a lower VAS, minor swelling and less recovery time compared to the rotatory-group. No lesions of the mandible nerve were detected with piezosurgery whereas surgery with rotary instruments resulted in 8% hypesthesia at least up to one week. The results of this study suggest that piezosurgery may be considered effective in cyst enucleation compared to traditional procedures with burs, since it grants the patients significantly less post-surgical pain and swelling. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Sagheb, Keyvan; Kumar, Vinay V; Azaripour, Adriano; Walter, Christian; Al-Nawas, Bilal; Kämmerer, Peer W
2017-02-01
The aim of this ex vivo study was to compare implant insertion procedures using piezosurgery and conventional drilling in different qualities of bone. Implant bed preparation time, generated heat, and primary implant stability were analyzed. Fresh ex vivo porcine bone block samples (cancellous, mixed, and cortical bone) were obtained. The bone quality was quantified by ultrasound transmission velocity (UTV). Each bone sample received three implants of the same diameter using each of the techniques of piezosurgery and conventional twist drills. Time for preparation was taken and the temperature while performing the osteotomy was measured using infrared spectroscopy. The primary implant stability after osteotomy was measured using resonance frequency analysis (RFA) and extrusion torque (ET). ANOVA with post hoc Tukey test was carried out to compare the values for the three different groups. The UTV values strongly correlated with the density of the bone samples. There was a significant increase in time (threefold, P < 0.05 [302 s vs. 122 s in cortical bone]) but no difference in the temperature for the piezo group (~37°C in cortical bone). Regardless of the osteotomy technique, there was a statistically significant increase in RFA and ET values in implants inserted in cancellous bone (RFA: piezo 77, drill 76; ET: piezo 22, drill 21), mixed bone (RFA: piezo 85, drill 86; ET: piezo 105, drill 61), and cortical bone (RFA: piezo 90, drill 87; ET piezo 184, drill 79) samples, respectively (P < 0.05). In between the different osteotomy groups, there was no difference in the RFA values but significant higher ET values in mixed/cortical bone samples in favor for the piezosurgery group. Piezosurgery and conventional implant bed drilling procedure do have similar mechanical outcomes regarding primary stability with high RFA values, but the preparation does need more time for piezosurgery group, so that piezosurgery might be a valuable tool in only very specific cases for implant bed preparation. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Toomarian, Lida; Rikhtegaran, Sahand; Sadighi, Mehrnoosh; Savadi Oskoee, Siavash; Alizadeh Oskoee, Parnian
2007-01-01
Dental handpiece is a source of contamination because it is in constant touch with the oral cavity. Sterilization does not seem to be sufficient to prevent penetration of microorganisms into air and water lines of the unit, because negative pressure developed by valves (which are placed in water outlets) and post shut-off inertial rotation of handpiece result in water and debris being sucked into air and water outlets of dental unit. The aim of this study was to compare dental unit contamination following use of clean head system handpieces and conventional handpieces. Twenty-two dental units in the Department of Pediatric Dentistry in Shahid Beheshti Faculty of Dentistry were used for the purpose of this study. A 1.5×108 cfu/mm3 concentration of Staphylococcus epidermis (SE) was used to contaminate the air and water outlets of dental units. Ten clean head system handpieces and 10 conventional handpieces were used for 30 seconds in the above-mentioned suspension. Microbial samples were collected from the air and water lines. Culturing and colony counting procedures were carried out. Data was analyzed by t-test; a value of p<0.01 was considered significant. Results demonstrated a significantly lower SE contamination in water outlets following the use of clean head system (p<0.01). A lower tendency of clean head system handpieces to transmit SE compared to conventional system makes them a better choice for infection control.
The Effect of Instruction on Conventional Expressions in L2 Pragmatics
ERIC Educational Resources Information Center
Bardovi-Harlig, Kathleen; Vellenga, Heidi E.
2012-01-01
This study investigates the effects of instruction (input plus focused metapragmatic noticing) on the oral production of conventional expressions, particularly those conventional expressions which perform specific pragmatic functions in English. Using a pre-test-instruction-post-test design we tested 36 university-level students in six intact…
Highly controlled vascular syringes for pericardiocentesis.
Ricciardi, Mark; Roldan, Carlos; Sibbitt, Randy; Sibbitt, Wilmer; Michael, Adrian; Palmer, Dennis
2010-12-01
The present study determined the utility and needle control characteristics of highly controlled vascular syringes for image-guided pericardiocentesis. Vascular syringes have been integrated into invasive cardiovascular procedures with improved patient safety, but to date have not been used in pericardiocentesis. To address this issue, we determined the method of use of vascular syringes for pericardiocentesis. A vascular syringe with reciprocating plungers, the reciprocating procedure device (RPD syringe), replaced the corresponding 10 ml and 20 ml conventional syringes in a standard pericardiocentesis tray. The vascular syringe is controlled with one hand, and can either aspirate or inject by pushing the corresponding aspiration or injection plunger. Four hundred and thirty seven subjects underwent vascular syringe procedures. The linear displacement method was used to precisely measure control of the needle tip in millimeters (mm) in vascular syringes compared to conventional syringes in 20 individual operators. Relative to the corresponding 10 ml and 20 ml conventional syringes, vascular syringes significantly reduced unintended forward penetration of the needle tip by 44% (7.0 ± 4.3 mm; p < 0.0001) and 53% (10.1 ± 5.5 mm; p < 0.0001), respectively, and reduced unintended retraction of the needle by 56% (2.7 ± 2.2 mm; p < 0.001) and 60% (3.5 ± 2.5 mm; p < 0.001), respectively. During pericardiocentesis, the mechanical syringe permitted facile one-handed aspiration and maintained the operator's ability to clear the needle. In the 437 vascular syringe procedures, there were no complications, with an estimated cost savings of $10-65 per procedure. Vascular syringes improve needle control in pericardiocentesis, promote patient safety and permit one-handed aspiration and injection.
A method of setting limits for the purpose of quality assurance
NASA Astrophysics Data System (ADS)
Sanghangthum, Taweap; Suriyapee, Sivalee; Kim, Gwe-Ya; Pawlicki, Todd
2013-10-01
The result from any assurance measurement needs to be checked against some limits for acceptability. There are two types of limits; those that define clinical acceptability (action limits) and those that are meant to serve as a warning that the measurement is close to the action limits (tolerance limits). Currently, there is no standard procedure to set these limits. In this work, we propose an operational procedure to set tolerance limits and action limits. The approach to establish the limits is based on techniques of quality engineering using control charts and a process capability index. The method is different for tolerance limits and action limits with action limits being categorized into those that are specified and unspecified. The procedure is to first ensure process control using the I-MR control charts. Then, the tolerance limits are set equal to the control chart limits on the I chart. Action limits are determined using the Cpm process capability index with the requirements that the process must be in-control. The limits from the proposed procedure are compared to an existing or conventional method. Four examples are investigated: two of volumetric modulated arc therapy (VMAT) point dose quality assurance (QA) and two of routine linear accelerator output QA. The tolerance limits range from about 6% larger to 9% smaller than conventional action limits for VMAT QA cases. For the linac output QA, tolerance limits are about 60% smaller than conventional action limits. The operational procedure describe in this work is based on established quality management tools and will provide a systematic guide to set up tolerance and action limits for different equipment and processes.
Friedmacher, Florian; Till, Holger
2015-11-01
In recent years, the use of robotic-assisted surgery (RAS) has expanded within pediatric surgery. Although increasing numbers of pediatric RAS case-series have been published, the level of evidence remains unclear, with authors mainly focusing on the comparison with open surgery rather than the corresponding laparoscopic approach. The aim of this study was to critically appraise the published literature comparing pediatric RAS with conventional minimally invasive surgery (MIS) in order to evaluate the current best level of evidence. A systematic literature-based search for studies comparing pediatric RAS with corresponding MIS procedures was performed using multiple electronic databases and sources. The level of evidence was determined using the Oxford Centre for Evidence-based Medicine (OCEBM) criteria. A total of 20 studies met defined inclusion criteria, reporting on five different procedures: fundoplication (n=8), pyeloplasty (n=8), nephrectomy (n=2), gastric banding (n=1), and sleeve gastrectomy (n=1). Included publications comprised 5 systematic reviews and 15 cohort/case-control studies (OCEBM Level 3 and 4, respectively). No studies of OCEBM Level 1 or 2 were identified. Limited evidence indicated reduced operative time (pyeloplasty) and shorter hospital stay (fundoplication) for pediatric RAS, whereas disadvantages were longer operative time (fundoplication, nephrectomy, gastric banding, and sleeve gastrectomy) and higher total costs (fundoplication and sleeve gastrectomy). There were no differences reported for complications, success rates, or short-term outcomes between pediatric RAS and conventional MIS in these procedures. Inconsistency was found in study design and follow-up with large clinical heterogeneity. The best available evidence for pediatric RAS is currently OCEBM Level 3, relating only to fundoplication and pyeloplasty. Therefore, higher-quality studies and comparative data for other RAS procedures in pediatric surgery are required.
A computer-controlled apparatus for Seebeck inhomogeneity testing of sheathed thermocouples
NASA Technical Reports Server (NTRS)
Burkett, Cecil G., Jr.; Bauserman, Willard A., Jr.
1993-01-01
Mineral-insulated metal-sheathed (MIMS) thermocouple assemblies are used throughout industry and research facilities as a method of temperature measurement where requirements for either harsh environmental conditions exist, or where rigidity of the measurement probe is required. Seebeck inhomogeneity is the abnormal variation of the Seebeck coefficient from point to point in a material. It is not disclosed in conventional calibration. A standardized method of measuring thermoelectric inhomogeneity along the thermocouple probe length is not available. Therefore, calibration for sheathed probes normally does not include testing of probe inhomogeneity. The measurement accuracy would be severely impacted if significant inhomogeneity and a temperature gradient were present in the same region of the probe. A computer-controlled system for determining inhomogeneities was designed, fabricated, and tested. This system provides an accurate method for the identification of the location of inhomogeneity along the length of a sheathed thermocouple and for the quantification of the inhomogeneity. This paper will discuss the apparatus and procedure used to perform these tests and will present data showing tests performed on sheathed thermocouple probes.
Wei, Ming-Li; Du, Yan-Jun; Reddy, Krishna R; Wu, Hao-Liang
2015-12-01
For viable and sustainable reuse of solidified/stabilized heavy metal-contaminated soils as roadway subgrade materials, long-term durability of these soils should be ensured. A new binder, KMP, has been developed for solidifying/stabilizing soils contaminated with high concentrations of heavy metals. However, the effects of long-term extreme weather conditions including freeze and thaw on the leachability and strength of the KMP stabilized contaminated soils have not been investigated. This study presents a systematic investigation on the impacts of freeze-thaw cycle on leachability, strength, and microstructural characteristics of the KMP stabilized soils spiked with Zn and Pb individually and together. For comparison purpose, Portland cement is also tested as a conventional binder. Several series of tests are conducted including the toxicity characteristic leaching procedure (TCLP), modified European Community Bureau of Reference (BCR) sequential extraction procedure, unconfined compression test (UCT), and mercury intrusion porosimetry (MIP). The results demonstrate that the freeze-thaw cycles have much less impact on the leachability and strength of the KMP stabilized soils as compared to the PC stabilized soils. After the freeze-thaw cycle tests, the KMP stabilized soils display much lower leachability, mass loss, and strength loss. These results are assessed based on the chemical speciation of Zn and Pb, and pore size distribution of the soils. Overall, this study demonstrates that the KMP stabilized heavy metal-contaminated soils perform well under the freeze-thaw conditions.
Volokhov, Dmitriy V; Graham, Laurie J; Brorson, Kurt A; Chizhikov, Vladimir E
2011-01-01
Mycoplasmas, particularly species of the genera Mycoplasma and Acholeplasma, are known to be occasional microbial contaminants of cell cultures that produce biologics. This presents a serious concern regarding the risk of mycoplasma contamination for research laboratories and commercial facilities developing and manufacturing cell-derived biological and biopharmaceutical products for therapeutic use. Potential undetected contamination of these products or process intermediates with mycoplasmas represents a potential safety risk for patients and a business risk for producers of biopharmaceuticals. To minimize these risks, monitoring for adventitious agents, such as viruses and mycoplasmas, is performed during the manufacture of biologics produced in cell culture substrates. The "gold standard" microbiological assay, currently recommended by the USP, EP, JP and the US FDA, for the mycoplasma testing of biologics, involves the culture of viable mycoplasmas in broth, agar plates and indicator cells. Although the procedure enables highly efficient mycoplasma detection in cell substrates and cell-derived products, the overall testing strategy is time consuming (a minimum of 28 days) and requires skilled interpretation of the results. The long time period required for these conventional assays does not permit their use for products with short shelf-lives or for timely 'go/no-go' decisions during routine in-process testing. PCR methodology has existed for decades, however PCR based and other alternative methods for mycoplasma detection have only recently been considered for application to biologics manufacture. The application of alternative nucleic acid-based, enzyme-based and/or recombinant cell-culture methods, particularly in combination with efficient sample preparation procedures, could provide advantages over conventional microbiological methods in terms of analytical throughput, simplicity, and turnaround time. However, a challenge to the application of alternative methods for detection of mycoplasmas remains whether these alternative methods can provide a limit of detection comparable or superior to those of the culture methods. An additional challenge is that nucleic acid amplification technique (NAT) methods do not allow for accurate discrimination between viable and non-viable mycoplasma contaminants, which might lead to false-positive results (e.g. from inactivated raw materials, etc.). Our review provides an overview of these alternative methods and discusses the pros and cons of their application for the testing of mycoplasmas in biologics and cell substrates. Published by Elsevier Ltd.
Strategies for Implementing Cell-Free DNA Testing.
Cuckle, Howard
2016-06-01
Maternal plasma cell-free (cf) DNA testing has higher discriminatory power for aneuploidy than any conventional multi-marker screening test. Several strategies have been suggested for introducing it into clinical practice. Secondary cfDNA, restricted only to women with positive conventional screening test, is generally cost saving and minimizes the need for invasive prenatal diagnosis but leads to a small loss in detection. Primary cfDNA, replacing conventional screening or retaining the nuchal translucency scan, is not currently cost-effective for third-party payers. Contingent cfDNA, testing about 20% of women with the highest risks based on a conventional test, is the preferred approach. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Farhat, C.; Park, K. C.; Dubois-Pelerin, Y.
1991-01-01
An unconditionally stable second order accurate implicit-implicit staggered procedure for the finite element solution of fully coupled thermoelasticity transient problems is proposed. The procedure is stabilized with a semi-algebraic augmentation technique. A comparative cost analysis reveals the superiority of the proposed computational strategy to other conventional staggered procedures. Numerical examples of one and two-dimensional thermomechanical coupled problems demonstrate the accuracy of the proposed numerical solution algorithm.