Linke, Axel; Walther, Thomas; Schuler, Gerhard
2010-03-01
Treatment of aortic stenosis remains challenging in older individuals, as their perioperative mortality for open heart surgery is increased due to comorbidities. Transcatheter aortic valve implantation using the CoreValve ReValving System (Medtronic, Minneapolis, USA) and the Edwards SAPIEN transcatheter heart valve (THV; Edwards Lifescience, Irvine, California, USA) represents an alternative to conventional valve replacement in elderly patients that have a high risk for conventional surgery. This article summarizes the evidence-base from recent clinical trials. The early results of these landmark studies suggest that transcatheter aortic valve implantation with either one of the prosthesis is feasible, safe, improves hemodynamics and, therefore, might be an alternative to conventional aortic valve replacement in very high-risk patients. However, all of the available transcatheter heart valves have certain disadvantages, limiting their use in daily clinical practice. The process of decision making, which valve to use and which access route to choose is illustrated in this article through clinical case scenarios. Additionally, the lessons learned thus far from the European perspective and the potential impact on the future use in the US are discussed. Despite of the progress in this field, we are still lacking an optimal transcatheter heart valve. Once it is available, we can take the plunge to compare transcatheter valve implantation with convention surgery in severe aortic stenosis!
[Percutaneously implantable aortic valve: the JenaValve concept evolution].
Figulla, Hans R; Ferrari, Markus
2006-10-01
Due to the increasing incidence of severe aortic stenosis in old and multimorbid patients, the percutaneous implantation of aortic valve-carrying stents has become an alternative to the surgical replacement of aortic valves. Starting in 1995, the authors developed a self-expanding stent which transferred the necessary forces for anchoring up to the aorta ascendens-a conception taken over from CoreValve. The further improvement of this idea over the past 11 years has led to a self-expanding, relatively short stent-valve system that is reliably positioned in the cusps of the old aortic valve and holds the old valve like a paper clip, thus transferring the holding forces physiologically. As compared to conventional systems, the sophisticated insertion catheter requires further chronic animal tests so as to represent a true alternative to the conventional surgical procedure.
Hurley, Eoghan T; O'Sullivan, Katie E; Segurado, Ricardo; Hurley, John P
2015-01-01
Sutureless aortic valve prostheses are anchored by radial force in a mechanism similar to that of transcatheter aortic valve implantation. Transcatheter aortic valve implantation is associated with an increased permanent pacemaker (PPM) requirement in a significant proportion of patients. We undertook a meta-analysis to examine the incidence of PPM insertion associated with sutureless compared with conventional surgical aortic valve replacement. A systematic review was conducted in accordance with the Prisma guidelines. All searches were performed on August 10, 2014. Studies between 2007 and 2014 were included in the search. A total of 832 patients were included in the sutureless group and 3,740 in the conventional group. Aortic cross-clamp (39.8 vs 62.4 minutes; P < 0.001) and cardiopulmonary bypass (64.9 vs 86.7 minutes; P = 0.002) times were shorter in the sutureless group. Permanent pacemaker implantation rate was higher in the sutureless cohort (9.1% vs 2.4%; P = 0.025). Sutureless aortic valve prostheses are associated with significantly shorter cardiopulmonary bypass and aortic cross-clamp times and a higher incidence of PPM insertion than conventional. Further investigation of the prognostic significance is required.
Centerless grinding of TiAl using conventional grinding wheels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, P.E.; Smits, D.; Eylon, D.
1995-12-31
Ordered gamma titanium aluminide (TiAl) based alloys are now under consideration for automotive valves because of their light weight and high strength at temperatures up to 850 C. Finishing comprises as much as 70% of the cost of an automotive valve, therefore the grindability of TiAl valves will influence their commercial viability. This study compared the grindability of the TiAl alloy Ti-47Al-2Nb-1.75Cr (at%) to standard valve steels, nickel base superalloys, and conventional titanium alloys using the centerless grinding process. Three grinding conditions simulating stem grinding were selected. The power requirements, grinding time, and grinding wheel consumption were used to estimatemore » the cost to grind TiAl on conventional centerless grinding equipment using vitrified bonded silicon carbide wheels. The metallurgical effects of rough and finish stem grinding cycles on the surface were determined. The grindability factor of TiAl, a measure of grinding cost, was slightly inferior to conventional valve steels, but much better than conventional titanium alloys. The high work hardening rate of the TiAl resulted in much better surface finish at high metal removal rates than that achieved in steels. No grinding cracks were observed, even under the rough grinding conditions. Microhardness profiles indicated significant work hardening of the surface under all three grinding conditions.« less
Pressure model of a four-way spool valve for simulating electrohydraulic control systems
NASA Technical Reports Server (NTRS)
Gebben, V. D.
1976-01-01
An equation that relates the pressure flow characteristics of hydraulic spool valves was developed. The dependent variable is valve output pressure, and the independent variables are spool position and flow. This causal form of equation is preferred in applications that simulate the effects of hydraulic line dynamics. Results from this equation are compared with those from the conventional valve equation, whose dependent variable is flow. A computer program of the valve equations includes spool stops, leakage spool clearances, and dead-zone characteristics of overlap spools.
The economic value of rapid deployment aortic valve replacement via full sternotomy.
Moore, Matt; Barnhart, Glenn R; Chitwood, W Randolph; Rizzo, John A; Gunnarsson, Candace; Palli, Swetha R; Grossi, Eugene A
2017-06-01
To compare the economic value of EDWARDS INTUITY Elite™ (EIE) valve system for rapid-deployment aortic valve replacement (RDAVR) in a full sternotomy (FS) approach (EIE-FS-RDAVR) versus FS-AVR using conventional stented bioprosthesis. A simulation model to compare each treatment's 30-day inpatient utilization and complication rates utilized: clinical end points obtained from the TRANSFORM trial patient subset (EIE-FS-RDAVR) and a best evidence review of the published literature (FS-AVR); and costs from the Premier database and published literature. EIE-FS-RDAVR costs $800 less than FS-AVR per surgery episode attributable to lowered complication rates and utilization. Combined with the lower mortality, EIE-FS-RDAVR was a superior (dominant) technology versus FS-AVR. This preliminary investigation of EIE-FS-RDAVR versus conventional FS-AVR found the EIE valve offered superior economic value over a 30-day period. Real-world analyses with additional long-term follow-up are needed to evaluate if this result can be replicated over a longer timeframe.
Miniature piezo electric vacuum inlet valve
Keville, Robert F.; Dietrich, Daniel D.
1998-03-24
A miniature piezo electric vacuum inlet valve having a fast pulse rate and is battery operated with variable flow capability. The low power (<1.6 watts), high pulse rate (<2 milliseconds), variable flow inlet valve is utilized for mass spectroscopic applications or other applications where pulsed or continuous flow conditions are needed. The inlet valve also has a very minimal dead volume of less than 0.01 std/cc. The valve can utilize, for example, a 12 Vdc input/750 Vdc, 3 mA output power supply compared to conventional piezo electric valves which require preloading of the crystal drive mechanism and 120 Vac, thus the valve of the present invention is smaller by a factor of three.
Properties of frozen dairy desserts processed by microfluidization of their mixes.
Olson, D W; White, C H; Watson, C E
2003-04-01
Sensory properties and rate of meltdown of nonfat (0% fat) and low-fat (2% fat) vanilla ice creams processed either by conventional valve homogenization or microfluidization of their mixes were compared with each other and to ice cream (10% fat) processed by conventional valve homogenization. Mixes for frozen dairy desserts containing 0, 2, and 10% fat were manufactured. Some of the nonfat and low-fat ice cream mixes were processed by microfluidization at 50, 100, 150, and 200 MPa, and the remaining nonfat and low-fat ice cream mixes and all of the ice cream mix were processed by conventional valve homogenization at 13.8 MPa, first stage, and 3.4 MPa, second stage. The finished frozen and hardened products were evaluated at d 1 and 45 for meltdown rate and for flavor and body and texture by preference testing. Nonfat and low-fat ice creams that usually had a slower meltdown were produced when processing their mixes by microfluidization instead of by conventional valve homogenization. Sensory scores for the ice cream were significantly higher than sensory scores for the nonfat and low-fat ice creams, but the sensory scores for the conventional valve homogenized controls for the nonfat ice cream and low-fat ice cream were not significantly different from the sensory scores for the nonfat ice cream and low-fat ice cream processed by microfluidization of the mixes, respectively. Microfluidization produced nonfat and low-fat ice creams that usually had a slower meltdown without affecting sensory properties.
Mixed mode fuel injector with individually moveable needle valve members
Stewart, Chris; Chockley, Scott A.; Ibrahim, Daniel R.; Lawrence, Keith; Tomaseki, Jay; Azam, Junru H.; Tian, Steven Ye; Shafer, Scott F.
2004-08-03
A fuel injector includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set controlled respectively, by first and second needle valve members. One of the needle valve members moves to an open position while the other needle valve member remains stationary for a homogeneous charge injection event. The former needle valve member stays stationary while the other needle valve member moves to an open position for a conventional injection event. One of the needle valve members is at least partially positioned in the other needle valve member. Thus, the injector can perform homogeneous charge injection events, conventional injection events, or even a mixed mode having both types of injection events in a single engine cycle.
Miniature piezo electric vacuum inlet valve
Keville, R.F.; Dietrich, D.D.
1998-03-24
A miniature piezo electric vacuum inlet valve having a fast pulse rate and is battery operated with variable flow capability is disclosed. The low power (<1.6 watts), high pulse rate (<2 milliseconds), variable flow inlet valve is utilized for mass spectroscopic applications or other applications where pulsed or continuous flow conditions are needed. The inlet valve also has a very minimal dead volume of less than 0.01 std/cc. The valve can utilize, for example, a 12 Vdc input/750 Vdc, 3 mA output power supply compared to conventional piezo electric valves which require preloading of the crystal drive mechanism and 120 Vac, thus the valve of the present invention is smaller by a factor of three. 6 figs.
Surgery for Young Adults With Aortic Valve Disease not Amenable to Repair.
Zakkar, Mustafa; Bruno, Vito Domanico; Visan, Alexandru Ciprian; Curtis, Stephanie; Angelini, Gianni; Lansac, Emmanuel; Stoica, Serban
2018-01-01
Aortic valve replacement is the gold standard for the management of patients with severe aortic stenosis or mixed pathology that is not amenable to repair according to currently available guidelines. Such a simplified approach may be suitable for many patients, but it is far from ideal for young adults considering emerging evidence demonstrating that conventional valve replacement in this cohort of patients is associated with inferior long-term survival when compared to the general population. Moreover; the utilisation of mechanical and bioprosthetic valves can significantly impact on quality and is linked to increased rates of morbidities. Other available options such as stentless valve, homografts, valve reconstruction and Ross operation can be an appealing alternative to conventional valve replacement. Young patients should be fully informed about all the options available - shared decision making is now part of modern informed consent. This can be achieved when referring physicians have a better understanding of the short and long term outcomes associated with every intervention, in terms of survival and quality of life. This review presents up to date evidence for available surgical options for young adults with aortic stenosis and mixed disease not amenable to repair.
Large Magnetoresistance at High Bias Voltage in Double-layer Organic Spin Valves
NASA Astrophysics Data System (ADS)
Subedi, R. C.; Liang, S. H.; Geng, R.; Zhang, Q. T.; Lou, L.; Wang, J.; Han, X. F.; Nguyen, T. D.
We report studies of magnetoresistance (MR) in double-layer organic spin valves (DOSV) using tris (8-hydroxyquinolinato) aluminum (Alq3) spacers. The device exhibits three distinct resistance levels depending on the relative magnetizations of the ferromagnetic electrodes. We observed a much weaker bias voltage dependence of MR in the device compared to that in the conventional organic spin valve (OSV). The MR magnitude reduces by the factor of two at 0.7 V bias voltage in the DOSV compared to 0.02 V in the conventional OSV. Remarkably, the MR magnitude reaches 0.3% at 6 V bias in the DOSVs, the largest MR response ever reported in OSVs at this bias. Our finding may have a significant impact on achieving high efficient bipolar OSVs strictly performed at high voltages. University of Georgia start-up fund, Ministry of Education, Singapore, National Natural Science Foundation of China.
NASA Astrophysics Data System (ADS)
Kamili Zahidi, M.; Razali Hanipah, M.
2017-10-01
A two-stroke poppet valve engine is developed to overcome the common problems in conventional two-stroke engine designs. However, replacing piston control port with poppet valve will resulted different flow behaviour. This paper presents the model and simulation result of three-dimensional (3D) port flow investigation of a two-stroke poppet valve engine. The objective of the investigation is to conduct a numerical investigation on port flow performance of two-stroke poppet valve engine and compare the results obtained from the experimental investigation. The model is to be used for the future numerical study of the engine. The volume flow rate results have been compared with the results obtained experimentally as presented in first part of this paper. The model has shown good agreement in terms of the flow rate at initial and final valve lifts but reduced by about 50% during half-lift region.
Simulation of Blood flow in Different Configurations Design of Bi-leaflet Mechanical Heart Valve
NASA Astrophysics Data System (ADS)
Hafizah Mokhtar, N.; Abas, Aizat
2018-05-01
In this work, two different designs of artificial heart valve were devised and then compared by considering the thrombosis, wear and valve orifice to anatomical orifice ratio of each mechanical heart valve. These different design configurations of bi-leaflet mechanical heart valves model are created through the use of Computer-aided design (CAD) modelling and simulated using Computational fluid dynamic (CFD) software. Design 1 is based on existing conventional bi-leaflet valve and design 2 based on modified bi-leaflet respectively. The flow pattern, velocity, vorticity and stress analysis have been done to justify the best design. Based on results, both of the designs show a Doppler velocity index of less than the allowable standard of 2.2 which is safe to be used as replacement of the human heart valve. However, design 2 shows that it has a lower possibility of cavitation issue which will lead to lower thrombosis and provide good central flow area of blood as compared to design 1.
Del Giglio, Mauro; Mikus, Elisa; Micari, Antonio; Calvi, Simone; Tripodi, Alberto; Campo, Gianluca; Maietti, Elisa; Castriota, Fausto; Cremonesi, Alberto
2018-01-01
Background Right anterior mini-thoracotomy (MIAVR) is a promising technique for aortic valve replacement. We aimed at comparing its outcomes with those obtained in a propensity-matched group of patients undergoing sternotomy at our two high-volume centers. Methods Main clinical and operative data of patients undergoing aortic valve replacement between January 2010 and May 2016 were retrospectively collected. A total of 678 patients were treated with a standard full sternotomy approach, while MIAVR was performed in 502. Propensity score matching identified 363 patients per each group. Results In-hospital mortality was not significantly different between the propensity-matched groups (1.7% in MIAVR patients vs. 2.2% in conventional sternotomy patients; P=0.79). No significant difference in the incidence of major post-operative complications was observed. Post-operative ventilation times (median 7, range 5–12 hours in MIAVR patients vs. median 7, range 5–12 in conventional sternotomy patients; P=0.72) were not significantly different between the two groups. Cardiopulmonary bypass time (61.0±21.0 vs. 65.9±24.7 min in conventional sternotomy group; P<0.01) and aortic cross-clamping time (48.3±16.7 vs. 53.2±19.6 min in full sternotomy group; P<0.01) were shorter in MIAVR group. EuroSCORE (OR 1.52, 95% CI, 1.12–2.06; P<0.01) was found to be the only independent predictor of intra-hospital mortality in the whole propensity-matched population. Conclusions Our experience shows that mini-access isolated aortic valve surgery is a reproducible, safe and effective procedure with similar outcomes and no longer operative times compared to conventional sternotomy. PMID:29707310
Mixed Mode Fuel Injector And Injection System
Stewart, Chris Lee; Tian, Ye; Wang, Lifeng; Shafer, Scott F.
2005-12-27
A fuel injector includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set that are controlled respectively by first and second three way needle control valves. Each fuel injector includes first and second concentric needle valve members. One of the needle valve members moves to an open position for a homogenous charge injection event, while the other needle valve member moves to an open position for a conventional injection event. The fuel injector has the ability to operate in a homogenous charge mode with a homogenous charge spray pattern, a conventional mode with a conventional spray pattern or a mixed mode.
Muneretto, Claudio; Alfieri, Ottavio; Cesana, Bruno Mario; Bisleri, Gianluigi; De Bonis, Michele; Di Bartolomeo, Roberto; Savini, Carlo; Folesani, Gianluca; Di Bacco, Lorenzo; Rambaldini, Manfredo; Maureira, Juan Pablo; Laborde, Francois; Tespili, Maurizio; Repossini, Alberto; Folliguet, Thierry
2015-12-01
We sought to investigate the clinical outcomes of patients with isolated severe aortic stenosis and an intermediate- to high-risk profile treated by means of conventional surgery (surgical aortic valve replacement), sutureless valve implantation, or transcatheter aortic valve replacement in a multicenter evaluation. Among 991 consecutive patients with isolated severe aortic stenosis and an intermediate- to high-risk profile (Society of Thoracic Surgeons score >4 and logistic European System for Cardiac Operative Risk Evaluation I >10), a propensity score analysis was performed on the basis of the therapeutic strategy: surgical aortic valve replacement (n = 204), sutureless valve implantation (n = 204), and transcatheter aortic valve replacement (n = 204). Primary end points were 30-day mortality and overall survival at 24-month follow-up; the secondary end point was survival free from a composite end point of major adverse cardiac events (defined as cardiac-related mortality, myocardial infarction, cerebrovascular accidents, and major hemorrhagic events) and periprosthetic regurgitation greater than 2. Thirty-day mortality was significantly higher in the transcatheter aortic valve replacement group (surgical aortic valve replacement = 3.4% vs sutureless = 5.8% vs transcatheter aortic valve replacement = 9.8%; P = .005). The incidence of postprocedural was 3.9% in asurgical aortic valve replacement vs 9.8% in sutureless vs 14.7% in transcatheter aortic valve replacement (P< .001) and peripheral vascular complications occurred in 0% of surgicalaortic valve replacement vs 0% of sutureless vs 9.8% transcatheter aortic valve replacement (P< .001). At 24-month follow-up, overall survival (surgical aortic valve replacement = 91.3% ± 2.4% vs sutureless = 94.9% ± 2.1% vs transcatheter aortic valve replacement = 79.5% ± 4.3%; P < .001) and survival free from the composite end point of major adverse cardiovascular events and periprosthetic regurgitation were significantly better in patients undergoing surgical aortic valve replacement and sutureless valve implantation than in patients undergoing transcatheter aortic valve replacement (surgical aortic valve replacement = 92.6% ± 2.3% vs sutureless = 96% ± 1.8% vs transcatheter aortic valve replacement = 77.1% ± 4.2%; P < .001). Multivariate Cox regression analysis identified transcatheter aortic valve replacement as an independent risk factor for overall mortality hazard ratio (hazard ratio, 2.5; confidence interval, 1.1-4.2; P = .018). The use of transcatheter aortic valve replacement in patients with an intermediate- to high-risk profile was associated with a significantly higher incidence of perioperative complications and decreased survival at short- and mid-term when compared with conventional surgery and sutureless valve implantation. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Physical and mental recovery after conventional aortic valve surgery.
Petersen, Johannes; Vettorazzi, Eik; Winter, Lena; Schmied, Wolfram; Kindermann, Ingrid; Schäfers, Hans-Joachim
2016-12-01
Physical and mental recovery are important factors to consider in the treatment of aortic valve disease, and the process of recovery is not well known. We investigated the course of physical and mental recovery directly after conventional aortic valve surgery. In a longitudinal study, 60 patients undergoing elective aortic valve surgery were studied preoperatively and at intervals of 4 weeks after aortic valve surgery. The last measurement was taken 6 months postoperatively. Measurements included the 6-minute walk test and N-terminal pro-B-type natriuretic peptide. Mental recovery was assessed by the Short Form Health Survey and the Hospital Anxiety and Depression Scale. All parameters were compared with published healthy norms. All parameters except for the anxiety score showed a significant decline after the first postoperative measurement at 1 week after aortic valve surgery. The baseline level was restored at 1 to 3 weeks (anxiety, depression, mental quality of life, Borg scale), 4 to 6 weeks (6-minute walk test, physical quality of life), and 9 weeks (N-terminal pro-B-type natriuretic peptide) after the first postoperative week. Significantly better values than preoperatively for the first time were reached at 2 to 3 weeks (anxiety, depression, mental quality of life), 5 weeks (6-minute walk test), 8 weeks (physical quality of life), and 12 weeks (N-terminal pro-B-type natriuretic peptide) after the first postoperative week. At 3 months postoperatively, significant improvements (P < .001) were seen in walk distance (+212 m), dyspnea (-1.11), physical (+12.38) and mental quality of life (+7.71), anxiety (-3.74), and depression (-3.62) compared with the first week postoperatively. At 6 months postoperatively, all parameters were significantly improved compared with preoperative data and, except for the N-terminal pro-B-type natriuretic peptide value, significantly better or equal compared with published healthy norms. After conventional aortic valve surgery, the most pronounced recovery was seen in the first 6 weeks postoperatively. Physical quality of life and N-terminal pro-B-type natriuretic peptide required a prolonged time for a complete recovery. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Hanedan, Muhammet Onur; Yuruk, Mehmet Ali; Parlar, Ali Ihsan; Ziyrek, Ugur; Arslan, Ali Kemal; Sayar, Ufuk; Mataraci, Ilker
2018-02-01
In elderly, high-risk surgical patients, sutureless aortic valve replacement (AVR) can often be an alternative to conventional AVR; shorter aortic cross-clamp and cardiopulmonary bypass times are the chief advantages. We compared the outcomes of sutureless AVR with those of conventional AVR in 70 elderly patients who underwent concomitant cardiac surgical procedures. We retrospectively analyzed the cases of 42 men and 28 women (mean age, 70.4 ± 10.3 yr; range, 34-93 yr) who underwent cardiac operations plus AVR with either a sutureless valve (group 1, n=38) or a conventional bioprosthetic or mechanical valve (group 2, n=32). Baseline patient characteristics were similar except for worse New York Heart Association functional status and the prevalence of diabetes mellitus in group 1. In group 1, the operative, cross-clamp, and cardiopulmonary bypass times were shorter (all P =0.001), postoperative drainage amounts were lower ( P =0.009), hospital stays were shorter ( P =0.004), and less red blood cell transfusion was needed ( P =0.037). Echocardiograms before patients' discharge from the hospital showed lower peak and mean aortic gradients in group 1 (mean transvalvular gradient, 8.4 ± 2.8 vs 12.2 ± 5.2 mmHg; P =0.012). We found that elderly, high-risk patients who underwent multiple cardiac surgical procedures and sutureless AVR had better hemodynamic outcomes and shorter ischemic times than did patients who underwent conventional AVR.
Aortic valve calcifications on chest films: how much calcium do I need?
Mahnken, Andreas H; Dohmen, Guido; Koos, Ralf
2011-08-01
Aortic valve calcifications (AVC) as seen on conventional chest films or on CT are associated with aortic valve stenosis (AVS). The absence of AVC on chest films does not exclude high grade AVS. The aim of this study was to analyse if there is a threshold for the detection of AVC from conventional chest films in patients suffering from high grade AVS. The explanted aortic valves of 29 patients (16 male, mean age 72.3 +/- 11.5 years) with high grade AVS were examined by dual-source CT. AVC were quantified using the Agatston AVC score. In all patients conventional chest films obtained the day before surgery were evaluated for the presence of AVC. Results were analysed with students t-test, Spearman's rank correlation and ROC analysis. On conventional chest films AVC were visible in 18 patients. On CT all specimen presented with AVC with an Agatston AVC score ranging from 40.7 to 1870 (mean 991.3 +/- 463.1). In patients with AVC visible on chest films the AVC score was significantly higher (1264.0 +/- 318.2) when compared with patients without visible calcifications (544.9 +/- 274.4; P < 0.0001). There was a strong correlation between the AVC score and the visibility of AVC on chest films (r = 0.781). ROC analysis identified an ideal threshold of 718 for AVC score to separate conventional chest films with and without visible AVC. Unlike in coronary calcifications, there is a threshold for identifying AVC from conventional chest films. This finding may be of diagnostic value, as conventional chest films may be used to semiquantitatively evaluate the extent of AVC.
The two-stroke poppet valve engine. Part 1: Intake and exhaust ports flow experimental assessments
NASA Astrophysics Data System (ADS)
Kamili Zahidi, M.; Razali Hanipah, M.; Ramasamy, D.; Noor, M. M.; Kadirgama, K.; Rahman, M. M.
2017-10-01
A two-stroke poppet valve engine is developed to overcome the common problems in conventional two-stroke engine designs. However, replacing piston control port with poppet valve will resulted different flow behaviour. This paper is looking at experimental assessment on a two-stroke poppet valve engine configuration to investigate the port flow performance. The aims are to evaluate the intake and exhaust coefficient of discharge and assess the twostroke capability of the cylinder head. The results has shown comparable coefficient of discharge values as production engine for the intake while the exhaust has higher values which is favourable for the two-stroke cycle operation.
Minimally invasive aortic valve replacement – pros and cons of keyhole aortic surgery
Szałański, Przemysław; Zembala, Michał; Filipiak, Krzysztof; Karolak, Wojciech; Wojarski, Jacek; Garbacz, Marcin; Kaczmarczyk, Aleksandra; Kwiecień, Anna; Zembala, Marian
2015-01-01
Over the last twenty years, minimally invasive aortic valve replacement (MIAVR) has evolved into a safe, well-tolerated and efficient surgical treatment option for aortic valve disease. It has been shown to reduce postoperative morbidity, providing faster recovery and rehabilitation, shorter hospital stay and better cosmetic results compared with conventional surgery. A variety of minimally invasive accesses have been developed and utilized to date. This concise review demonstrates and discusses surgical techniques used in contemporary approaches to MIAVR and presents the most important results of MIAVR procedures. PMID:26336491
A pulse-tube refrigerator using variable-resistance orifice
NASA Astrophysics Data System (ADS)
Huang, B. J.; Sun, B. W.
2003-01-01
In the present study, we propose a new design of orifice pulse-tube refrigerator (VROPT) using a variable-resistance valve to replace the conventional orifice. The variable-resistance orifice (VRO) is basically a high-speed solenoidal valve similar to the fuel jet device widely used in automobile engines. By changing the frequency and periods of ON and OFF of the valve through an electronic device, we can change the flow resistance of the VRO. This thus provides a possibility for an OPT to be controlled on-line during operation. From the results obtained in the present study, we have shown that VROPT is able to achieve on-line control by regulating the duty cycle d or frequency fv of the VRO. We also show that VROPT will not loss its thermal performance as compared to conventional OPT.
Comparison of superior septal approach with left atriotomy in mitral valve surgery
Aydin, Ebuzer; Arslan, Akin; Ozkokeli, Mehmet
2014-01-01
Objective In this study, we aimed to compare clinical outcomes of superior transseptal approach with the conventional left atriotomy in patients undergoing mitral valve surgery. Methods Between January 2010 and November 2012, a total of 91 consecutive adult patients (39 males, 52 females; mean age: 54.0±15.4 years; range, 16 to 82 years) who underwent mitral valve surgery in the Division of Cardiovascular Surgery at Koşuyolu Training Hospital were included. The patients were randomized to either superior transseptal approach (n=47) or conventional left atriotomy (n=44). Demographic characteristics of the patients, comorbidities, additional interventions, intraoperational data, pre- and postoperative electrophysiological study findings, and postoperative complications were recorded. Results Of all patients, 86.7% (n=79) were in New York Heart Association Class III, while 12 were in New York Heart Association Class IV. All patients underwent annuloplasty (42.9%) or valve replacement surgery (57.1%). There was no significant difference in pre- and postoperative electrocardiogram findings between the groups. Change from baseline in the cardiac rhythm was statistically significant in superior transseptal approach group alone (P<0.001). There was no statistically significant difference in mortality rate between the groups. Permanent pacemaker implantation was performed in 10.6% of the patients in superior transseptal approach group and 4.5% in the conventional left atriotomy group. No statistically significant difference in bleeding, total length of hospital and intensive care unit stay, the presence of low cardiac output syndrome was observed between the groups. Conclusion Our study results suggest that superior transseptal approach does not lead to serious or fatal adverse effects on sinus node function or atrial vulnerability, compared to conventional approach. PMID:25372911
Thermal stability of Mn-Ir-based specular spin valve structure
NASA Astrophysics Data System (ADS)
Yoon, S. Y.; Lee, D. H.; Jeon, D. M.; Kim, J. H.; Yoon, D. H.; Suh, S. J.
2004-05-01
We studied the thermal properties of specular and conventional spin valves. The specular spin valve showed better thermal properties (e.g. slow MR degradation and sheet resistance increment) than those of conventional spin valve. It is considered that the Mn-Co-Fe-O is formed in the NOL at 543-578 K and this acts as a diffusion barrier for Mn during high-temperature annealing process.
Dual mode fuel injector with one piece needle valve member
Lawrence, Keith E.; Hinrichsen, Michael H.; Buckman, Colby
2005-01-18
A fuel injector includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set controlled respectively by inner and outer needle value members. The homogenous charged nozzle outlet set is defined by an outer needle value member that is moveably positioned in an injector body, which defines the conventional nozzle outlet set. The inner needle valve member is positioned in the outer needle valve member. The outer needle valve member is a piece component that includes at least one external guide surface, an external value surface and an internal valve seat.
The German Aortic Valve Registry (GARY): in-hospital outcome
Hamm, Christian W.; Möllmann, Helge; Holzhey, David; Beckmann, Andreas; Veit, Christof; Figulla, Hans-Reiner; Cremer, J.; Kuck, Karl-Heinz; Lange, Rüdiger; Zahn, Ralf; Sack, Stefan; Schuler, Gerhard; Walther, Thomas; Beyersdorf, Friedhelm; Böhm, Michael; Heusch, Gerd; Funkat, Anne-Kathrin; Meinertz, Thomas; Neumann, Till; Papoutsis, Konstantinos; Schneider, Steffen; Welz, Armin; Mohr, Friedrich W.
2014-01-01
Background Aortic stenosis is a frequent valvular disease especially in elderly patients. Catheter-based valve implantation has emerged as a valuable treatment approach for these patients being either at very high risk for conventional surgery or even deemed inoperable. The German Aortic Valve Registry (GARY) provides data on conventional and catheter-based aortic procedures on an all-comers basis. Methods and results A total of 13 860 consecutive patients undergoing repair for aortic valve disease [conventional surgery and transvascular (TV) or transapical (TA) catheter-based techniques] have been enrolled in this registry during 2011 and baseline, procedural, and outcome data have been acquired. The registry summarizes the results of 6523 conventional aortic valve replacements without (AVR) and 3464 with concomitant coronary bypass surgery (AVR + CABG) as well as 2695 TV AVI and 1181 TA interventions (TA AVI). Patients undergoing catheter-based techniques were significantly older and had higher risk profiles. The stroke rate was low in all groups with 1.3% (AVR), 1.9% (AVR + CABG), 1.7% (TV AVI), and 2.3% (TA AVI). The in-hospital mortality was 2.1% (AVR) and 4.5% (AVR + CABG) for patients undergoing conventional surgery, and 5.1% (TV AVI) and AVI 7.7% (TA AVI). Conclusion The in-hospital outcome results of this registry show that conventional surgery yields excellent results in all risk groups and that catheter-based aortic valve replacements is an alternative to conventional surgery in high risk and elderly patients. PMID:24022003
Conradi, Lenard; Kloth, Benjamin; Seiffert, Moritz; Schirmer, Johannes; Koschyk, Dietmar; Blankenberg, Stefan; Reichenspurner, Hermann; Diemert, Patrick; Treede, Hendrik
2014-12-01
Recently, the feasibility of valve-in-valve procedures using current first-generation transcatheter heart valves (THV) in cases of structural valve degeneration has been reported as an alternative to conventional open repeat valve replacement. By design, certain biological valve xenografts carry a high risk of coronary ostia occlusion due to lateral displacement of leaflets after valve-in-valve procedures. In the present report we aimed to prove feasibility and safety of transapical valve-in-valve implantation of the JenaValve THV in two cases of degenerated Mitroflow bioprostheses. We herein report two cases of successful transapical valve-in-valve procedures using a JenaValve THV implanted in Sorin Mitroflow bioprostheses for structural valve degeneration. Both patients were alive and in good clinical condition at 30 days from the procedure. However, increased transvalvular gradients were noted in both cases. Transcatheter valve-in-valve implantation of a JenaValve THV is a valid alternative for patients with degenerated Mitroflow bioprostheses of sufficient size and in the presence of short distances to the coronary ostia who are too ill for conventional repeat open heart surgery. Increased pressure gradients have to be expected and weighed against the disadvantages of other treatment options when planning such a procedure.
Bardakci, Hasmet; Altıntaş, Garip; Çiçek, Omer Faruk; Kervan, Umit; Yilmaz, Sevinc; Kaplan, Sadi; Birincioglu, Cemal Levent
2013-05-01
To compare the international normalised ratio (INR) value of patients evaluated using the CoaguChek XS versus conventional laboratory methods, in the period after open-heart surgery for mechanical valve replacement until a therapeutic range is achieved using vitamin K antagonists (VKA) together with low molecular weight heparin (LMWH). One hundred and five patients undergoing open-heart surgery for mechanical valve replacement were enrolled. Blood samples were collected from patients before surgery, and on the second and fifth postoperative days, simultaneously for both the point of care device and conventional laboratory techniques. Patients were administered VKA together with LMWH at therapeutic doses (enoxaparin 100 IU/kg twice daily) subcutaneously, until an effective range was achieved on approximately the fifth day after surgery. The mean INR values using the CoaguChek XS preoperatively and on the second and fifth days postoperatively were 1.20 (SD ± 0.09), 1.82 (SD ± 0.45), and 2.55 (SD ± 0.55), respectively. Corresponding results obtained using conventional laboratory techniques were 1.18 (SD ± 0.1), 1.81 (SD ± 0.43), and 2.51 (SD ± 0.58). The correlation coefficient was r = 0.77 preoperatively, r = 0.981 on postoperative day 2, and r = 0.983 on postoperative day 5. Results using the CoaguChek XS Handheld Coagulation Analyzer correlated strongly with conventional laboratory methods, in the bridging period between open-heart surgery for mechanical valve replacement and the achievement of a therapeutic range on warfarin and LMWH. © 2013 Wiley Periodicals, Inc.
Evaluation of mitral valve replacement anchoring in a phantom
NASA Astrophysics Data System (ADS)
McLeod, A. Jonathan; Moore, John; Lang, Pencilla; Bainbridge, Dan; Campbell, Gordon; Jones, Doug L.; Guiraudon, Gerard M.; Peters, Terry M.
2012-02-01
Conventional mitral valve replacement requires a median sternotomy and cardio-pulmonary bypass with aortic crossclamping and is associated with significant mortality and morbidity which could be reduced by performing the procedure off-pump. Replacing the mitral valve in the closed, off-pump, beating heart requires extensive development and validation of surgical and imaging techniques. Image guidance systems and surgical access for off-pump mitral valve replacement have been previously developed, allowing the prosthetic valve to be safely introduced into the left atrium and inserted into the mitral annulus. The major remaining challenge is to design a method of securely anchoring the prosthetic valve inside the beating heart. The development of anchoring techniques has been hampered by the expense and difficulty in conducting large animal studies. In this paper, we demonstrate how prosthetic valve anchoring may be evaluated in a dynamic phantom. The phantom provides a consistent testing environment where pressure measurements and Doppler ultrasound can be used to monitor and assess the valve anchoring procedures, detecting pararvalvular leak when valve anchoring is inadequate. Minimally invasive anchoring techniques may be directly compared to the current gold standard of valves sutured under direct vision, providing a useful tool for the validation of new surgical instruments.
Three-dimensional echocardiographic assessment of the repaired mitral valve.
Maslow, Andrew; Mahmood, Feroze; Poppas, Athena; Singh, Arun
2014-02-01
This study examined the geometric changes of the mitral valve (MV) after repair using conventional and three-dimensional echocardiography. Prospective evaluation of consecutive patients undergoing mitral valve repair. Tertiary care university hospital. Fifty consecutive patients scheduled for elective repair of the mitral valve for regurgitant disease. Intraoperative transesophageal echocardiography. Assessments of valve area (MVA) were performed using two-dimensional planimetry (2D-Plan), pressure half-time (PHT), and three-dimensional planimetry (3D-Plan). In addition, the direction of ventricular inflow was assessed from the three-dimensional imaging. Good correlations (r = 0.83) and agreement (-0.08 +/- 0.43 cm(2)) were seen between the MVA measured with 3D-Plan and PHT, and were better than either compared to 2D-Plan. MVAs were smaller after repair of functional disease repaired with an annuloplasty ring. After repair, ventricular inflow was directed toward the lateral ventricular wall. Subgroup analysis showed that the change in inflow angle was not different after repair of functional disease (168 to 171 degrees) as compared to those presenting with degenerative disease (168 to 148 degrees; p<0.0001). Three-dimensional imaging provides caregivers with a unique ability to assess changes in valve function after mitral valve repair. Copyright © 2014 Elsevier Inc. All rights reserved.
Kim, Joon Bum; Ejiofor, Julius I; Yammine, Maroun; Camuso, Janice M; Walsh, Conor W; Ando, Masahiko; Melnitchouk, Serguei I; Rawn, James D; Leacche, Marzia; MacGillivray, Thomas E; Cohn, Lawrence H; Byrne, John G; Sundt, Thoralf M
2016-05-01
Surgical dogma suggests that homografts should be used preferentially, compared with conventional xenograft or mechanical prostheses, in the setting of infective endocarditis (IE), because they have greater resistance to infection. However, comparative data that support this notion are limited. From the prospective databases of 2 tertiary academic centers, we identified 304 consecutive adult patients (age ≥17 years) who underwent surgery for active IE involving the aortic valve (AV), in the period 2002 to 2014. Short- and long-term outcomes were evaluated using propensity scores and inverse-probability weighting to adjust for selection bias. Homografts, and xenograft and mechanical prostheses, were used in 86 (28.3%), 139 (45.7%), and 79 (26.0%) patients, respectively. Homografts were more often used in the setting of prosthetic valve endocarditis (58.1% vs 28.8%, P = .002) and methicillin-resistant Staphylococcus (25.6% vs 12.1%, P = .002), compared with conventional prostheses. Early mortality occurred in 17 (19.8%) in the homograft group, and 20 (9.2%) in the conventional group (P = .019). During follow-up (median: 29.4 months; interquartile-range: 4.7-72.6 months), 60 (19.7%) patients died, and 23 (7.7%) experienced reinfection, with no significant differences in survival (P = .23) or freedom from reinfection rates (P = .65) according to the types of prostheses implanted. After adjustments for baseline characteristics, using propensity-score analyses, use of a homograft did not significantly affect early death (odds ratio 1.61; 95% confidence interval [CI], 0.73-3.40, P = .23), overall death (hazard ratio 1.10; 95% CI, 0.62-1.94, P = .75), or reinfection (hazard ratio 1.04; 95% CI, 0.49-2.18, P = .93). No significant benefit to use of homografts was demonstrable with regard to resistance to reinfection in the setting of IE. The choice among prosthetic options should be based on technical and patient-specific factors. Lack of availability of homografts should not impede appropriate surgical intervention. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Parihar, Jitendra Kumar Singh; Jain, Vaibhav Kumar; Kaushik, Jaya; Mishra, Avinash
2017-03-01
To compare the outcome of pars-plana-modified Ahmed glaucoma valve (AGV) versus limbal-based conventional AGV into the anterior chamber, in patients undergoing penetrating keratoplasty (PK) for glaucoma with coexisting corneal diseases. In this prospective randomized clinical trial, 58 eyes of 58 patients with glaucoma and coexisting corneal disease were divided into two groups. Group 1 (29 eyes of 29 patients) included patients undergoing limbal-based conventional AGV into the anterior chamber (AC) along-with PK and group 2 (29 eyes of 29 patients) included those undergoing pars-plana-modified AGV along-with PK. Outcome measures included corneal graft clarity, intraocular pressure (IOP), number of antiglaucoma medications, and postoperative complications. Patients were followed up for a minimum period of 2 years. Out of 58 eyes (58 patients), 50 eyes (50 patients: 25 eyes of 25 patients each in group 1 and group 2) completed the study and were analyzed. Complete success rate for AGV (group 1: 76%; group 2: 72%; p = 0.842) and corneal graft clarity (group 1: 68%; group 2: 76%; p = 0.081) were comparable between the two groups at 2 years. Graft failure was more in conventional AGV (32%) as compared to pars plana-modified AGV (24%) but not statistically significant (p = 0.078) at 2 years. Though both procedures were comparable in various outcome measures, pars-plana-modified AGV is a viable option for patients undergoing PK, as it provides a relatively better corneal graft survival rate and lesser complications that were associated with conventional AGV.
Direct Comparison of the Edwards Intuity Elite and Sorin Perceval S Rapid Deployment Aortic Valves.
Liakopoulos, Oliver J; Gerfer, Stephen; Weider, Simone; Rahmanian, Parwis; Zeriouh, Mohamed; Eghbalzadeh, Kaveh; Sabashnikov, Anton; Choi, Yeong-Hoon; Wippermann, Jens; Wahlers, Thorsten
2018-01-01
Rapid deployment aortic valve replacement (RDAVR) has emerged as an attractive alternative to conventional aortic valve replacement. This single-center study directly compared two commercially available rapid deployment valves with regard to clinical outcomes, valve-related complications, and hemodynamic performance. A total of consecutive 156 patients underwent RDAVR with the Intuity Elite (Edwards Lifesciences, Irvine, CA [Intuity group, n = 117] or the Perceval S (Sorin Group Italia Srl, Saluggia, Italy [Perceval group, n = 39]) between September 2012 and March 2016 at our institution. Perioperative data, including 30-day all-cause mortality, and echocardiographic measurements were assessed and retrospectively analyzed from our institutional database. Preoperative variables, including mean age (77 ± 5 years), European System for Cardiac Operative Risk Evaluation (6.8 ± 2.1), and body mass index (27 ± 5 kg/m 2 ), did not differ between groups. More male patients (60% versus 15%) with a higher body surface area (1.9 ± 0.2 m 2 versus 1.7 ± 0.2 m 2 ) and body weight (78 ± 13 kg versus 71 ± 15 kg) were in the Intuity group compared with the Perceval group, respectively (p < 0.05). Implanted RDAVR size (23.3 ± 1.8 mm versus 23.4 ± 1.5 mm), concomitant coronary artery bypass graft surgery (48% versus 33%), number of grafts, cardiopulmonary bypass, and aortic clamp time were comparable between the Intuity group and the Perceval group. Thirty-day mortality (Intuity 2.6% versus Perceval 5.1%) and valve-related complications (Intuity 12.0% versus Perceval 20.5%), including postoperative pacemaker implantation (Intuity 8.5% versus Perceval 12.8%), did not differ between groups. At discharge echocardiography, indexed effective orifice area was higher in the Intuity group, but peak or mean pressure gradients were comparable between groups. Performing RDAVR with the Intuity and Perceval rapid deployment valves provides comparable good clinical outcomes and valve hemodynamics, with low valve-related complication rates. The rate of pacemaker implantation was comparable for both rapid deployment valves, ranging from 8% to 13%. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Realistic Vascular Replicator for TAVR Procedures.
Rotman, Oren M; Kovarovic, Brandon; Sadasivan, Chander; Gruberg, Luis; Lieber, Baruch B; Bluestein, Danny
2018-04-13
Transcatheter aortic valve replacement (TAVR) is an over-the-wire procedure for treatment of severe aortic stenosis (AS). TAVR valves are conventionally tested using simplified left heart simulators (LHS). While those provide baseline performance reliably, their aortic root geometries are far from the anatomical in situ configuration, often overestimating the valves' performance. We report on a novel benchtop patient-specific arterial replicator designed for testing TAVR and training interventional cardiologists in the procedure. The Replicator is an accurate model of the human upper body vasculature for training physicians in percutaneous interventions. It comprises of fully-automated Windkessel mechanism to recreate physiological flow conditions. Calcified aortic valve models were fabricated and incorporated into the Replicator, then tested for performing TAVR procedure by an experienced cardiologist using the Inovare valve. EOA, pressures, and angiograms were monitored pre- and post-TAVR. A St. Jude mechanical valve was tested as a reference that is less affected by the AS anatomy. Results in the Replicator of both valves were compared to the performance in a commercial ISO-compliant LHS. The AS anatomy in the Replicator resulted in a significant decrease of the TAVR valve performance relative to the simplified LHS, with EOA and transvalvular pressures comparable to clinical data. Minor change was seen in the mechanical valve performance. The Replicator showed to be an effective platform for TAVR testing. Unlike a simplified geometric anatomy LHS, it conservatively provides clinically-relevant outcomes and complement it. The Replicator can be most valuable for testing new valves under challenging patient anatomies, physicians training, and procedural planning.
Intake flow modeling in a four stroke diesel using KIVA3
NASA Technical Reports Server (NTRS)
Hessel, R. P.; Rutland, C. J.
1993-01-01
Intake flow for a dual intake valved diesel engine is modeled using moving valves and realistic geometries. The objectives are to obtain accurate initial conditions for combustion calculations and to provide a tool for studying intake processes. Global simulation parameters are compared with experimental results and show good agreement. The intake process shows a 30 percent difference in mass flows and average swirl in opposite directions across the two intake valves. The effect of the intake process on the flow field at the end of compression is examined. Modeling the intake flow results in swirl and turbulence characteristics that are quite different from those obtained by conventional methods in which compression stroke initial conditions are assumed.
Katada, Y; Nakagawa, S; Minakata, K; Odaka, M; Taue, H; Sato, Y; Yonezawa, A; Kayano, Y; Yano, I; Nakatsu, T; Sakamoto, K; Uehara, K; Sakaguchi, H; Yamazaki, K; Minatoya, K; Sakata, R; Matsubara, K
2017-10-01
Anticoagulation therapy with warfarin requires periodic monitoring of prothrombin time-international normalized ratio (PT-INR) and adequate dose adjustments based on the data to minimize the risk of bleeding and thromboembolic events. In our hospital, we have developed protocol-based pharmaceutical care, which we called protocol-based pharmacotherapy management (PBPM), for warfarin therapy. The protocol requires pharmacists to manage timing of blood sampling for measuring PT-INR and warfarin dosage determination based on an algorithm. This study evaluated the efficacy of PBPM in warfarin therapy by comparing to conventional pharmaceutical care. From October 2013 to June 2015, a total of 134 hospitalized patients who underwent cardiovascular surgeries received post-operative warfarin therapy. The early series of patients received warfarin therapy as the conventional care (control group, n=77), whereas the latter received warfarin therapy based on the PBPM (PBPM group, n=68). These patients formed the cohort of the present study and were retrospectively analysed. The indications for warfarin included aortic valve replacement (n=56), mitral valve replacement (n=4), mitral valve plasty (n=22) and atrial fibrillation (n=29). There were no differences in patients' characteristics between both groups. The percentage time in therapeutic range in the first 10 days was significantly higher in the PBPM group (47.1%) than that in the control group (34.4%, P<.005). The average time to reach the steady state was significantly (P<.005) shorter in the PBPM group compared to the control group (7.3 vs 8.6 days). Warfarin therapy based on our novel PBPM was clinically safe and resulted in significantly better anticoagulation control compared to conventional care. © 2017 John Wiley & Sons Ltd.
Aydin, Unal; Gul, Mehmet; Aslan, Serkan; Akkaya, Emre; Yildirim, Aydin
2015-04-28
Transcatheter valve implantation is a novel interventional technique, which was developed as an alternative therapy for surgical aortic valve replacement in inoperable patients with severe aortic stenosis. Despite limited experience in using transcatheter valve implantation for mitral and aortic regurgitation, transapical transcatheter aortic valve implantation and valve-in-valve implantation for degenerated mitral valve bioprosthesis can be performed in high-risk patients who are not candidates for conventional replacement surgery. In this case, we present the simultaneous transcatheter valve implantation via transapical approach for both degenerated bioprosthetic mitral valve with severe regurgitation and pure severe aortic regurgitation.
Oborny, Michael C.; Paul, Phillip H.; Hencken, Kenneth R.; Frye-Mason, Gregory C.; Manginell, Ronald P.
2001-01-01
A valve for controlling fluid flows. This valve, which includes both an actuation device and a valve body provides: the ability to incorporate both the actuation device and valve into a unitary structure that can be placed onto a microchip, the ability to generate higher actuation pressures and thus control higher fluid pressures than conventional microvalves, and a device that draws only microwatts of power. An electrokinetic pump that converts electric potential to hydraulic force is used to operate, or actuate, the valve.
Sun, Xuefei; Kelly, Ryan T.; Danielson, William F.; Agrawal, Nitin; Tang, Keqi; Smith, Richard D.
2011-01-01
A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersection geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, little sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed. PMID:21520147
Currie, Maria E; Trejos, Ana Luisa; Rayman, Reiza; Chu, Michael W A; Patel, Rajni; Peters, Terry; Kiaii, Bob B
2013-01-01
The purpose of this study was to determine the effect of three-dimensional (3D) binocular, stereoscopic, and two-dimensional (2D) monocular visualization on robotics-assisted mitral valve annuloplasty versus conventional techniques in an ex vivo animal model. In addition, we sought to determine whether these effects were consistent between novices and experts in robotics-assisted cardiac surgery. A cardiac surgery test-bed was constructed to measure forces applied during mitral valve annuloplasty. Sutures were passed through the porcine mitral valve annulus by the participants with different levels of experience in robotics-assisted surgery and tied in place using both robotics-assisted and conventional surgery techniques. The mean time for both the experts and the novices using 3D visualization was significantly less than that required using 2D vision (P < 0.001). However, there was no significant difference in the maximum force applied by the novices to the mitral valve during suturing (P = 0.7) and suture tying (P = 0.6) using either 2D or 3D visualization. The mean time required and forces applied by both the experts and the novices were significantly less using the conventional surgical technique than when using the robotic system with either 2D or 3D vision (P < 0.001). Despite high-quality binocular images, both the experts and the novices applied significantly more force to the cardiac tissue during 3D robotics-assisted mitral valve annuloplasty than during conventional open mitral valve annuloplasty. This finding suggests that 3D visualization does not fully compensate for the absence of haptic feedback in robotics-assisted cardiac surgery.
Lightweight Valve Closes Duct Quickly
NASA Technical Reports Server (NTRS)
Fournier, Walter L.; Burgy, N. Frank
1991-01-01
Expanding balloon serves as lightweight emergency valve to close wide duct. Uninflated balloon stored in housing of duct. Pad resting on burst diaphragm protects balloon from hot gases in duct. Once control system triggers valve, balloon inflates rapidly to block duct. Weighs much less than does conventional butterfly, hot-gas, or poppet valve capable of closing duct of equal diameter.
Heuts, Samuel; Maessen, Jos G; Sardari Nia, Peyman
2016-05-01
With the emergence of a new concept aimed at individualization of patient care, the focus will shift from whether a minimally invasive procedure is better than conventional treatment, to the question of which patients will benefit most from which technique? The superiority of minimally invasive valve surgery (MIVS) has not yet been proved. We believe that through better patient selection advantages of this technique can become more pronounced. In our current study, we evaluate the feasibility of 3D computed tomography (CT) imaging reconstruction in the preoperative planning of patients referred for MIVS. We retrospectively analysed all consecutive patients who were referred for minimally invasive mitral valve surgery (MIMVS) and minimally invasive aortic valve replacement (MIAVR) to a single surgeon in a tertiary referral centre for MIVS between March 2014 and 2015. Prospective preoperative planning was done for all patients and was based on evaluations by a multidisciplinary heart-team, an echocardiography, conventional CT images and 3D CT reconstruction models. A total of 39 patients were included in our study; 16 for mitral valve surgery (MVS) and 23 patients for aortic valve replacement (AVR). Eleven patients (69%) within the MVS group underwent MIMVS. Five patients (31%) underwent conventional MVS. Findings leading to exclusion for MIMVS were a tortuous or slender femoro-iliac tract, calcification of the aortic bifurcation, aortic elongation and pericardial calcifications. Furthermore, 2 patients had a change of operative strategy based on preoperative planning. Seventeen (74%) patients in the AVR group underwent MIAVR. Six patients (26%) underwent conventional AVR. Indications for conventional AVR instead of MIAVR were an elongated ascending aorta, ascending aortic calcification and ascending aortic dilatation. One patient (6%) in the MIAVR group was converted to a sternotomy due to excessive intraoperative bleeding. Two mortalities were reported during conventional MVS. There were no mortalities reported in the MIMVS, MIAVR or conventional AVR group. Preoperative planning of minimally invasive left-sided valve surgery with 3D CT reconstruction models is a useful and feasible method to determine operative strategy and exclude patients ineligible for a minimally invasive approach, thus potentially preventing complications. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
NASA Technical Reports Server (NTRS)
Casabianca, C. C.
1978-01-01
Device requires no moving parts and has less stringent tolerances. Device uses magnetostrictive powdered metal and electromagnets, rather than solenoid. Device is more reliable than conventional valves.
Brun, Klaus; Gernentz, Ryan S.
2010-07-27
A method and system for fine-tuning the motion of suction or discharge valves associated with cylinders of a reciprocating gas compressor, such as the large compressors used for natural gas transmission. The valve's primary driving force is conventional, but the valve also uses an electromagnetic coil to sense position of the plate (or other plugging element) and to provide an opposing force prior to impact.
Visualizing anatomical evidences on atrioventricular conduction system for TAVI.
Kawashima, Tomokazu; Sato, Fumi
2014-06-01
Visualizing the anatomy of the atrioventricular (AV) conduction axis substantiates that there is remarkable inter-individual variation at the macro- and microscopic levels, and that the atrioventricular bundle and left bundle branch are located more anteriorly, distally, and cranially and much closer to the aortic root complex than previously thought. The AV conduction system may therefore be compromised during implantation of a transcatheter aortic valve prosthesis, which may account for the relatively high incidence of new cardiac conduction abnormalities when conventional prosthetic valves are used. The design of the newer JenaValve® may afford advantages over more conventional valves by avoiding the high-risk implantation area and the potential for coronary ostia obstruction. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
[Extracorporeal ventriculoatrial shunt with the use of one-way ball valve].
Kubo, Shigeki; Takimoto, Hiroshi; Hosoi, Kazuki; Toyota, Shingo; Takakura, Shuji; Hayashi, Yasuhiro; Ueno, Masato; Morisako, Toshitaka; Karasawa, Jun; Ninaga, Hideo; Yoshimine, Toshiki
2002-04-01
We developed a simple system of an "extracorporeal" ventriculoatrial (VA) shunt using a one-way ball valve (Acty valve II, Kaneka Medix) to release the patient from postoperative constraint during the ventricular drainage. The system is constructed in such a way that the ventricular drainage tube is connected to the central venous catheter via a one-way valve. The CSF is regulated by using the valve and is diverted into the systemic circulation as in the conventional ventriculoatrial shunt. After 2 or 3 weeks of CSF diversion through the extracorporeal VA shunt, a ventriculoperitoneal shunt is placed if hydrocephalus is apparent by temporary occlusion of the system. We applied this system to 4 patients with hydrocephalus, and we found it useful and free from adverse effects. The patient was freed from physical constraint involved in conventional ventricular drainage and an effective program of early rehabilitation was able to be started.
Thermally Generated Spin Signals in a Nondegenerate Silicon Spin Valve
NASA Astrophysics Data System (ADS)
Yamashita, Naoto; Ando, Yuichiro; Koike, Hayato; Miwa, Shinji; Suzuki, Yoshishige; Shiraishi, Masashi
2018-05-01
Thermally generated spin signals are observed in a nondegenerate Si spin valve. The spin-dependent Seebeck effect is used for thermal spin-signal generation. A thermal gradient of about 200 mK at the interface of Fe and Si enables the generation of a spin voltage of 8 μ V at room temperature. A simple expansion of the conventional spin-drift-diffusion model that takes into account the spin-dependent Seebeck effect shows that semiconductor materials are more promising for thermal spin-signal generation comparing than metallic materials, and thus enable efficient heat recycling in semiconductor spin devices.
Fernández, Angel L; Varela, Eduardo; Martínez, Lucía; Martínez, Amparo; Sierra, Juan; González-Juanatey, José R; Regueiro, Benito
2010-10-01
With a novel real-time multiplex polymerase chain reaction test, the LightCycler SeptiFast® test, 25 bacterial and fungal species can be identified directly in blood. The SeptiFast® test has been used for rapid etiologic diagnosis in infectious endocarditis using blood samples but has not been evaluated directly on cardiac vegetations in patients being treated for infectious endocarditis. We prospectively analyzed 15 samples of heart valve tissue with active infectious endocarditis using the SeptiFast® test and compared the test's sensitivity with that of blood culture, valve tissue culture, and the SeptiFast® test in blood. The sensitivity of the SeptiFast test in heart valve tissue was 100%. The test results confirmed the diagnosis obtained using blood culture in 13 cases and identified the pathogen in 2 cases where blood culture tested negative. The sensitivity of the SeptiFast® test in heart valve tissue was greater than that obtained with conventional culture of vegetations or with the SeptiFast test in blood.
The Leipzig experience with robotic valve surgery.
Autschbach, R; Onnasch, J F; Falk, V; Walther, T; Krüger, M; Schilling, L O; Mohr, F W
2000-01-01
The study describes the single-center experience using robot-assisted videoscopic mitral valve surgery and the early results with a remote telemanipulator-assisted approach for mitral valve repair. Out of a series of 230 patients who underwent minimally invasive mitral valve surgery, in 167 patients surgery was performed with the use of robotic assistance. A voice-controlled robotic arm was used for videoscopic guidance in 152 cases. Most recently, a computer-enhanced telemanipulator was used in 15 patients to perform the operation remotely. The mitral valve was repaired in 117 and replaced in all other patients. The voice-controlled robotic arm (AESOP 3000) facilitated videoscopic-assisted mitral valve surgery. The procedure was completed without the need for an additional assistant as "solo surgery." Additional procedures like radiofrequency ablation and tricuspid valve repair were performed in 21 and 4 patients, respectively. Duration of bypass and clamp time was comparable to conventional procedures (107 A 34 and 50 A 16 min, respectively). Hospital mortality was 1.2%. Using the da Vinci telemanipulation system, remote mitral valve repair was successfully performed in 13 of 15 patients. Robotic-assisted less invasive mitral valve surgery has evolved to a reliable technique with reproducible results for primary operations and for reoperations. Robotic assistance has enabled a solo surgery approach. The combination with radiofrequency ablation (Mini Maze) in patients with chronic atrial fibrillation has proven to be beneficial. The use of telemanipulation systems for remote mitral valve surgery is promising, but a number of problems have to be solved before the introduction of a closed chest mitral valve procedure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Xuefei; Kelly, Ryan T.; Danielson, William F.
2011-04-26
A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersectionmore » geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, no sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed.« less
NASA Astrophysics Data System (ADS)
Stefanski, Frederik; Minorowicz, Bartosz; Persson, Johan; Plummer, Andrew; Bowen, Chris
2017-01-01
The potential to actuate proportional flow control valves using piezoelectric ceramics or other smart materials has been investigated for a number of years. Although performance advantages compared to electromagnetic actuation have been demonstrated, a major obstacle has proven to be ferroelectric hysteresis, which is typically 20% for a piezoelectric actuator. In this paper, a detailed study of valve control methods incorporating hysteresis compensation is made for the first time. Experimental results are obtained from a novel spool valve actuated by a multi-layer piezoelectric ring bender. A generalised Prandtl-Ishlinskii model, fitted to experimental training data from the prototype valve, is used to model hysteresis empirically. This form of model is analytically invertible and is used to compensate for hysteresis in the prototype valve both open loop, and in several configurations of closed loop real time control system. The closed loop control configurations use PID (Proportional Integral Derivative) control with either the inverse hysteresis model in the forward path or in a command feedforward path. Performance is compared to both open and closed loop control without hysteresis compensation via step and frequency response results. Results show a significant improvement in accuracy and dynamic performance using hysteresis compensation in open loop, but where valve position feedback is available for closed loop control the improvements are smaller, and so conventional PID control may well be sufficient. It is concluded that the ability to combine state-of-the-art multi-layer piezoelectric bending actuators with either sophisticated hysteresis compensation or closed loop control provides a route for the creation of a new generation of high performance piezoelectric valves.
Development of myoelectric control type speaking valve with low flow resistance
NASA Astrophysics Data System (ADS)
Ooe, Katsutoshi; Sakurai, Kohei; Mimaki, Shinya
2015-12-01
We aimed to develop welfare devices for patients with phonation disorder. One of these devices is the electrical controltype speaking valve system. The conventional speaking valves have one-way valve architecture, they open when the user breathes in, and they close when user breathes out and produce voices. This type is very simple and tough, but some users feel closeness in case of exhalation without phonation. This problem is caused by its mechanism what can not be controlled by user's will. Therefore, we proposed an electrical control-type speaking valve system to resolve this problem. This valve is controlled by neck myoelectric signal of sternohyoid muscle. From our previous report, it was clarified that this valve had better performance about easy-to-breath. Furthermore, we proposed the compact myoelectric control-type speaking valve system. The new-type speaking valve was enough small to attach the human body, and its opening area is larger than that of conventional one. Additionally, we described the improvement of flow channel shape by using of FEM analysis. According to the result of the analysis, it was clarified that the shape-improved speaking valve gets the low flow resistance channel in case of inspiration. In this report, we tried to make the flow resistance lower by the shape of current plates, in case of both inspiration and exhalation. From the result of FEM analysis, our speaking valve could get better flow channel than older one.
Effect of the sinus of valsalva on the closing motion of bileaflet prosthetic heart valves.
Ohta, Y; Kikuta, Y; Shimooka, T; Mitamura, Y; Yuhta, T; Dohi, T
2000-04-01
Conventional bileaflet prosthetic mechanical heart valves close passively with backflow. Naturally, the valve has problems associated with closure, such as backflow, water hammer effect, and fracture of the leaflet. On the other hand, in the case of the natural aortic valve, the vortex flow in the sinus of Valsalva pushes the leaflet to close, and the valve starts the closing motion earlier than the prosthetic valve as the forward flow decelerates. This closing mechanism is thought to decrease backflow at valve closure. In this study, we propose a new bileaflet mechanical valve resembling a drawbridge in shape, and the prototype valve was designed so that the leaflet closes with the help of the vortex flow in the sinus. The test valve was made of aluminum alloy, and its closing motion was compared to that of the CarboMedics (CM) valve. Both valves were driven by a computer controlled hydraulic mock circulator and were photographed at 648 frames/s by a high speed charge-coupled device (CCD) camera. Each frame of the valve motion image was analyzed with a personal computer, and the opening angles were measured. The flow rate was set as 5.0 L/min. The system was pulsed with 70 bpm, and the systolic/diastolic ratio was 0.3. Glycerin water was used as the circulation fluid at room temperature, and polystyrene particles were used to visualize the streamline. The model of the sinus of Valsalva was made of transparent silicone rubber. As a result, high speed video analysis showed that the test valve started the closing motion 41 ms earlier than the CM valve, and streamline analysis showed that the test valve had a closing mechanism similar to the natural one with the effect of vortex flow. The structure of the test valve was thought to be effective for soft closure and could solve problems associated with closure.
Jahandardoost, Mehdi; Fradet, Guy; Mohammadi, Hadi
2016-03-01
To date, to the best of the authors' knowledge, in almost all of the studies performed around the hemodynamics of bileaflet mechanical heart valves, a heart rate of 70-72 beats/min has been considered. In fact, the heart rate of ~72 beats/min does not represent the entire normal physiological conditions under which the aortic or prosthetic valves function. The heart rates of 120 or 50 beats/min may lead to hemodynamic complications, such as plaque formation and/or thromboembolism in patients. In this study, the hemodynamic performance of the bileaflet mechanical heart valves in a wide range of normal and physiological heart rates, that is, 60-150 beats/min, was studied in the opening phase. The model considered in this study was a St. Jude Medical bileaflet mechanical heart valve with the inner diameter of 27 mm in the aortic position. The hemodynamics of the native valve and the St. Jude Medical valve were studied in a variety of heart rates in the opening phase and the results were carefully compared. The results indicate that peak values of the velocity profile downstream of the valve increase as heart rate increases, as well as the location of the maximum velocity changes with heart rate in the St. Jude Medical valve model. Also, the maximum values of shear stress and wall shear stresses downstream of the valve are proportional to heart rate in both models. Interestingly, the maximum shear stress and wall shear stress values in both models are in the same range when heart rate is <90 beats/min; however, these values significantly increase in the St. Jude Medical valve model when heart rate is >90 beats/min (up to ~40% growth compared to that of the native valve). The findings of this study may be of importance in the hemodynamic performance of bileaflet mechanical heart valves. They may also play an important role in design improvement of conventional prosthetic heart valves and the design of the next generation of prosthetic valves, such as percutaneous valves. © IMechE 2016.
NASA Technical Reports Server (NTRS)
Friedell, M. V.
1980-01-01
Wrench converts gripping action of hand to rotary motion without imparting reactive moments or forces on part being turned or on operator. Wrench should be useful in undersea operations and other delicate work where reactive forces and torques have to be controlled. In design for valve tightening, tool resembles cross between conventional spanner wrench and pilers. One handle engages valve body; second handle has ratchet pawl that engages toothed coupling ring on perimeter of valve handle. When operator squeezes wrench handles, valve handle rotates with respect to valve body.
A microfluidic multi-injector for gradient generation.
Chung, Bong Geun; Lin, Francis; Jeon, Noo Li
2006-06-01
This paper describes a microfluidic multi-injector (MMI) that can generate temporal and spatial concentration gradients of soluble molecules. Compared to conventional glass micropipette-based methods that generate a single gradient, the MMI exploits microfluidic integration and actuation of multiple pulsatile injectors to generate arbitrary overlapping gradients that have not previously been possible. The MMI device is fabricated in poly(dimethylsiloxane) (PDMS) using multi-layer soft lithography and consists of fluidic channels and control channels with pneumatically actuated on-chip barrier valves. Repetitive actuation of on-chip valves control pulsatile release of solution that establishes microscopic chemical gradients around the orifice. The volume of solution released per actuation cycle ranged from 30 picolitres to several hundred picolitres and increased linearly with the duration of valve opening. The shape of the measured gradient profile agreed closely with the simulated diffusion profile from a point source. Steady state gradient profiles could be attained within 10 minutes, or less with an optimized pulse sequence. Overlapping gradients from 2 injectors were generated and characterized to highlight the advantages of MMI over conventional micropipette assays. The MMI platform should be useful for a wide range of basic and applied studies on chemotaxis and axon guidance.
Complementary role of cardiac CT in the assessment of aortic valve replacement dysfunction
Moss, Alastair J; Dweck, Marc R; Dreisbach, John G; Williams, Michelle C; Mak, Sze Mun; Cartlidge, Timothy; Nicol, Edward D; Morgan-Hughes, Gareth J
2016-01-01
Aortic valve replacement is the second most common cardiothoracic procedure in the UK. With an ageing population, there are an increasing number of patients with prosthetic valves that require follow-up. Imaging of prosthetic valves is challenging with conventional echocardiographic techniques making early detection of valve dysfunction or complications difficult. CT has recently emerged as a complementary approach offering excellent spatial resolution and the ability to identify a range of aortic valve replacement complications including structural valve dysfunction, thrombus development, pannus formation and prosthetic valve infective endocarditis. This review discusses each and how CT might be incorporated into a multimodal cardiovascular imaging pathway for the assessment of aortic valve replacements and in guiding clinical management. PMID:27843568
Value of Robotically Assisted Surgery for Mitral Valve Disease
Mihaljevic, Tomislav; Koprivanac, Marijan; Kelava, Marta; Goodman, Avi; Jarrett, Craig; Williams, Sarah J.; Gillinov, A. Marc; Bajwa, Gurjyot; Mick, Stephanie L.; Bonatti, Johannes; Blackstone, Eugene H.
2014-01-01
Importance The value of robotically assisted surgery for mitral valve disease is questioned because the high cost of care associated with robotic technology may outweigh its clinical benefits. Objective To investigate conditions under which benefits of robotic surgery mitigate high technology costs. Design Clinical cohort study comparing costs of robotic vs. three contemporaneous conventional surgical approaches for degenerative mitral disease. Surgery was performed from 2006–2011, and comparisons were based on intent-to-treat, with propensity-matching used to reduce selection bias. Setting Large multi-specialty academic medical center. Participants 1,290 patients aged 57±11 years, 27% women, underwent mitral repair for regurgitation from posterior leaflet prolapse. Robotic surgery was used in 473, complete sternotomy in 227, partial sternotomy in 349, and anterolateral thoracotomy in 241. Three propensity-matched groups were formed based on demographics, symptoms, cardiac and noncardiac comorbidities, valve pathophysiology, and echocardiographic measurements: robotic vs. sternotomy (n=198 pairs) vs. partial sternotomy (n=293 pairs) vs. thoracotomy (n=224 pairs). Interventions Mitral valve repair. Main Outcome Measures Cost of care, expressed as robotic capital investment, maintenance, and direct technical hospital cost, and benefit of care, based on differences in recovery time. Results Median cost of care for robotically assisted surgery exceeded the cost of alternative approaches by 27% (−5%, 68%), 32% (−6%, 70%), and 21% (−2%, 54%) (median [15th, 85th percentiles]) for complete sternotomy, partial sternotomy, and anterolateral thoracotomy, respectively. Higher operative costs were partially offset by lower postoperative costs and earlier return to work: median 35 days for robotic surgery, 49 for complete sternotomy, 56 for partial sternotomy, and 42 for anterolateral thoracotomy. Resulting net differences in cost of robotic surgery vs. the three alternatives were 16% (−15%, 55%), 16% (−19%, 51%), and 15% (−7%, 49%), respectively. Beyond a volume threshold of 55–100 robotic cases per year, confidence limits for the cost of robotic surgery broadly overlapped those of conventional approaches. Conclusions In exchange for higher procedural costs, robotically assisted mitral valve surgery offers the clinical benefit of least invasive surgery, lowest postoperative cost, and fastest return to work. The value of robotically assisted surgery comparable to conventional approaches can only be realized in high-volume centers. PMID:24848944
NASA Technical Reports Server (NTRS)
Wojciechowski, Bogdan V. (Inventor); Pegg, Robert J. (Inventor)
2003-01-01
A fast-acting valve includes an annular valve seat that defines an annular valve orifice between the edges of the annular valve seat, an annular valve plug sized to cover the valve orifice when the valve is closed, and a valve-plug holder for moving the annular valve plug on and off the annular valve seat. The use of an annular orifice reduces the characteristic distance between the edges of the valve seat. Rather than this distance being equal to the diameter of the orifice, as it is for a conventional circular orifice, the characteristic distance equals the distance between the inner and outer radii (for a circular annulus). The reduced characteristic distance greatly reduces the gap required between the annular valve plug and the annular valve seat for the valve to be fully open, thereby greatly reducing the required stroke and corresponding speed and acceleration of the annular valve plug. The use of a valve-plug holder that is under independent control to move the annular valve plug between its open and closed positions is important for achieving controllable fast operation of the valve.
Minimally invasive aortic valve replacement in high risk patient groups
Lewis, Harriet; Benedetto, Umberto; Caputo, Massimo; Angelini, Gianni; Vohra, Hunaid A.
2017-01-01
Minimally invasive aortic valve replacement (AVR) aims to preserve the sternal integrity and improve postoperative outcomes. In low risk patients, this technique can be achieved with comparable mortality to the conventional approach and there is evidence of possible reduction in intensive care and hospital length of stay, transfusion requirement, renal dysfunction, improved respiratory function and increased patient satisfaction. In this review, we aim to asses if these benefits can be transferred to the high risk patient groups. We therefore, discuss the available evidence for the following high risk groups: elderly patients, re-operative surgery, poor lung function, pulmonary hypertension, obesity, concomitant procedures and high risk score cohorts. PMID:28740685
Eitz, Thomas; Schenk, Soren; Fritzsche, Dirk; Bairaktaris, Andreas; Wagner, Otto; Koertke, Heinrich; Koerfer, Reiner
2008-03-01
Although prosthetic valves are durable and easy to implant, the need for lifetime warfarin-based anticoagulation restricts their exclusive usage. We investigated if anticoagulation self-management improves outcome in a single-center series. Between 1994 and 1998, 765 patients with prosthetic valve replacements were prospectively enrolled and randomized to receive conventional anticoagulation management by their primary physician (group 1, n = 295) or to pursue anticoagulation self-management (group 2, n = 470). A study head office was implemented to coordinate and monitor anticoagulation protocols, international normalized ratios (INR), and adverse events. Patients were instructed on how to obtain and test their own blood samples and to adjust warfarin dosages according to the measured INR (target range, 2.5 to 4). Mean INR values were slightly yet significantly smaller in group 1 than in group 2 (2.8 +/- 0.7 vs 3.0 +/- .6, p < 0.001). Moreover, INR values of patients with conventional INR management were frequently measured outside the INR target range, whereas those with anticoagulation self-management mostly remained within the range (35% vs 21%, p < 0.001). In addition, the scatter of INR values was smaller if self-managed. Freedom from thromboembolism at 3, 12, and 24 months, respectively, was 99%, 95%, and 91% in group 1 compared with 99%, 98%, and 96% in group 2 (p = 0.008). Bleeding events were similar in both groups. Time-related multivariate analysis identified INR self-management and higher INR as independent predictors for better outcome. Anticoagulation self-management can improve INR profiles up to 2 years after prosthetic valve replacement and reduce adverse events. Current indications of prosthetic rather than biologic valve implantations may be extended if the benefit of INR self-management is shown by future studies with longer follow-up.
Magnetostrictive GMR spin valves with composite FeGa/FeCo free layers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Luping; Institute of Materials Science, School of Materials Science and Engineering, Shanghai University, Shanghai 200072; Zhan, Qingfeng, E-mail: zhanqf@nimte.ac.cn, E-mail: runweili@nimte.ac.cn
2016-03-15
We have fabricated strain-sensitive spin valves on flexible substrates by utilizing the large magnetostrictive FeGa alloy to promote the strain sensitivity and the composite free layer of FeGa/FeCo to avoid the drastic reduction of giant magnetoresistance (GMR) ratio. This kind of spin valve (SV-FeGa/FeCo) displays a MR ratio about 5.9%, which is comparable to that of the conventional spin valve (SV-FeCo) with a single FeCo free layer. Different from the previously reported works on magnetostrictive spin valves, the SV-FeGa/FeCo displays an asymmetric strain dependent GMR behavior. Upon increasing the lateral strain, the MR ratio for the ascending branch decreases moremore » quickly than that for the descending branch, which is ascribed to the formation of a spiraling spin structure around the FeGa/FeCo interface under the combined influences of both magnetic field and mechanical strain. A strain sensitivity of GF = 7.2 was achieved at a magnetic bias field of -30 Oe in flexible SV-FeGa/FeCo, which is significantly larger than that of SV-FeCo.« less
Profile of Heart Donors from the Human Valve Bank of the Santa Casa de Misericórdia de Curitiba.
Ferreira, Renata Maria; da Costa, Marise Teresinha Brenner Affonso; Canciglieri Junior, Osiris; Sant'Anna, Ângelo Márcio Oliveira
2016-04-01
Human heart valves are used as replacement valves and have satisfactory functional results compared with conventional prostheses. Characterize the profile of effective heart donors from the human valve bank of the santa casa de misericórdia de curitiba and analyze the association between the profile variables. It consists of a retrospective and quantitative study of electronic medical records from heart donors for heart valves. every heart donation made to the bank between january 2004 and december 2014 was studied. 2,149 donations were analyzed, from donors aged 0 to 71 years old, with an average of 34.9 ± 15.03 years old. most donors were male 65.7% (n=1,411) and 34.3% (n=738) were female. among the most frequent causes of the donors' death are trauma at 53% (n=1,139) and cerebral vascular accident at 34.2% (n=735). there was significant statistical association between the analyzed variables. There has been an improvement in brazil's donation rate, being essential that the tissue banks work together with the state and federal district centers for notification, procurement and distribution of organs in order to increase the number of donors.
Moreno, Sandra; Parra, Beatriz; Botero, Javier E; Moreno, Freddy; Vásquez, Daniel; Fernández, Hugo; Alba, Sandra; Gallego, Sara; Castillo, Gilberto; Contreras, Adolfo
2017-12-01
Periodontitis is an infectious disease that affects the support tissue of the teeth and it is associated with different systemic diseases, including cardiovascular disease. Microbiological studies facilitate the detection of microorganisms from subgingival and cardiovascular samples. To describe the cultivable periodontal microbiota and the presence of microorganisms in heart valves from patients undergoing valve replacement surgery in a clinic in Cali. We analyzed 30 subgingival and valvular tissue samples by means of two-phase culture medium, supplemented blood agar and trypticase soy agar with antibiotics. Conventional PCR was performed on samples of valve tissue. The periodontal pathogens isolated from periodontal pockets were: Fusobacterium nucleatum (50%), Prevotella intermedia/ nigrescens (40%), Campylobacter rectus (40%), Eikenella corrodens (36.7%), Gram negative enteric bacilli (36.7%), Porphyromonas gingivalis (33.3%), and Eubacterium spp. (33.3%). The pathogens isolated from the aortic valve were Propionibacterium acnes (12%), Gram negative enteric bacilli (8%), Bacteroides merdae (4%), and Clostridium bifermentans (4%), and from the mitral valve we isolated P. acnes and Clostridium beijerinckii. Conventional PCR did not return positive results for oral pathogens and bacterial DNA was detected only in two samples. Periodontal microbiota of patients undergoing surgery for heart valve replacement consisted of species of Gram-negative bacteria that have been associated with infections in extraoral tissues. However, there is no evidence of the presence of periodontal pathogens in valve tissue, because even though there were valve and subgingival samples positive for Gram-negative enteric bacilli, it is not possible to maintain they corresponded to the same phylogenetic origin.
Simple Check Valves for Microfluidic Devices
NASA Technical Reports Server (NTRS)
Willis, Peter A.; Greer, Harold F.; Smith, J. Anthony
2010-01-01
A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.
Development of Long-Lifetime Pulsed Gas Valves for Pulsed Electric Thrusters
NASA Technical Reports Server (NTRS)
Burkhardt, Wendel M.; Crapuchettes, John M.; Addona, Brad M.; Polzin, Kurt A.
2015-01-01
It is advantageous for gas-fed pulsed electric thrusters to employ pulsed valves so propellant is only flowing to the device during operation. The propellant utilization of the thruster will be maximized when all the gas injected into the thruster is acted upon by the fields produced by the electrical pulse. Gas that is injected too early will diffuse away from the thruster before the electrical pulse can act to accelerate the propellant. Gas that is injected too late will miss being accelerated by the already-completed electrical pulse. As a consequence, the valve must open quickly and close equally quickly, only remaining open for a short duration. In addition, the valve must have only a small amount of volume between the sealing body and the thruster so the front and back ends of the pulse are as coincident as possible with the valve cycling, with very little latent propellant remaining in the feed lines after the valve is closed. For a real mission of interest, a pulsed thruster can be expected to pulse at least 10(exp 10) - 10(exp 11) times, setting the range for the number of times a valve must open and close. The valves described in this paper have been fabricated and tested for operation in an inductive pulsed plasma thruster (IPPT) for in-space propulsion. In general, an IPPT is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged, producing a high-current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed, it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. The valve characteristics needed for the IPPT application require a fast-acting valve capable of a minimum of 10(exp 10) valve actuation cycles. Since even 10(exp 9) cycles is well above anything demonstrated, this lower value was selected as the design point for the present work. The valve seal must remain leak-tight throughout operation, and the body must maintain a low internal leakage at relatively high operating temperatures. The full set of design requirements used for this program are summarized in Table 1. In this work, we describe two pulsed gas valves that have been fabricated to have long lifetime and demonstrate the characteristics listed above. The first is a miniaturized, conventional electromagnet-based valve while the second is a piezoelectric-based valve design. The conventional valve, shown in Fig. 1, is opened by use of a solenoid electromagnetic actuator. When current is applied to the solenoid coil, magnetic forces pull the plunger away from the valve seat, allowing fluid to flow through the valve. Removal of electrical current permits the spring and fluid pressure to seat the plunger, halting the flow of fluid. The valve body is fabricated from 304L corrosion resistant steel (CRES) and while the parts that form the magnetic circuit are fabricated from 430 CRES. This material does not have optimum magnetic properties, but its corrosion resistance permits incorporation into a design without requiring an additional plating process. A viton O-ring compound (Parker V0884-75), selected for its mechanical strength at elevated temperatures, was used for the valve seat seal. The design was based solely on the use of analytical sizing calculations, as opposed to a more rigorous finite element analysis. While this valve is small and relatively lightweight, it does not represent a design that is optimized for mass and/or a given volume envelope. The piezoelectric valve is a "puller" valve design. Applying a voltage to the piezo crystal causes it to elongate and pull a pintle off the seat, opening the valve. The valve seal consists of the pintle with an external, spherically-formed tip fabricated from Inconel 625 and the seat fabricated from Inconel 718 and possessing a spherical surface that permits the pintle to align with the valve body centerline after each cycle, maintaining the circumferential metal-on-metal seal. The contact stress on the valve pintle is expected in the worst case to be 96.5 MPa (14 ksi), which is well below the work hardening value of 413.7 MPa (60 ksi) for Inconel 615. Results presented in this work will compare the performance of each valve, both to each other and to the valve design requirements given in Table 1. In general, both valves meet all the performance envelope requirements, but the piezoelectric valve consumes considerably less power and has a faster response time over the conventional solenoid-driven valves.
Longitudinal On-Column Thermal Modulation for Comprehensive Two-Dimensional Liquid Chromatography.
Creese, Mari E; Creese, Mathew J; Foley, Joe P; Cortes, Hernan J; Hilder, Emily F; Shellie, Robert A; Breadmore, Michael C
2017-01-17
Longitudinal on-column thermal modulation for comprehensive two-dimensional liquid chromatography is introduced. Modulation optimization involved a systematic investigation of heat transfer, analyte retention, and migration velocity at a range of temperatures. Longitudinal on-column thermal modulation was realized using a set of alkylphenones and compared to a conventional valve-modulator employing sample loops. The thermal modulator showed a reduced modulation-induced pressure impact than valve modulation, resulting in reduced baseline perturbation by a factor of 6; yielding a 6-14-fold improvement in signal-to-noise. A red wine sample was analyzed to demonstrate the potential of the longitudinal on-column thermal modulator for separation of a complex sample. Discrete peaks in the second dimension using the thermal modulator were 30-55% narrower than with the valve modulator. The results shown herein demonstrate the benefits of an active focusing modulator, such as reduced detection limits and increased total peak capacity.
Bilge, Mehmet; Alsancak, Yakup; Ali, Sina; Yasar, Ayse Saatci
2015-05-01
Transcatheter aortic valve implantation (TAVI) is a new promising therapeutic option for patients with symptomatic severe calcific aortic valve stenosis (AS) who are inoperable or at high risk for conventional cardiac surgery. Percutaneous transvenous mitral commissurotomy (PTMC) is performed routinely in patients with severe mitral stenosis (MS) having a favorable anatomy. Although concurrent TAVI and PTMC is a theoretically possible approach in the treatment of patients with severe AS and MS who are unsuitable for conventional surgery, no cases have yet been reported in which this combined technique is used. For patients with severe AS and MS, the standard therapy is replacement of both the mitral and aortic valves. Herein are presented the details of a 52-year-old woman with urethral carcinoma, in whom simultaneous TAVI and PTMC was the chosen technique to treat combined severe rheumatic AS and MS in a single procedure.
NASA Technical Reports Server (NTRS)
Farner, Bruce
2013-01-01
A moveable valve for controlling flow of a pressurized working fluid was designed. This valve consists of a hollow, moveable floating piston pressed against a stationary solid seat, and can use the working fluid to seal the valve. This open/closed, novel valve is able to use metal-to-metal seats, without requiring seat sliding action; therefore there are no associated damaging effects. During use, existing standard high-pressure ball valve seats tend to become damaged during rotation of the ball. Additionally, forces acting on the ball and stem create large amounts of friction. The combination of these effects can lead to system failure. In an attempt to reduce damaging effects and seat failures, soft seats in the ball valve have been eliminated; however, the sliding action of the ball across the highly loaded seat still tends to scratch the seat, causing failure. Also, in order to operate, ball valves require the use of large actuators. Positioning the metal-to-metal seats requires more loading, which tends to increase the size of the required actuator, and can also lead to other failures in other areas such as the stem and bearing mechanisms, thus increasing cost and maintenance. This novel non-sliding seat surface valve allows metal-to-metal seats without the damaging effects that can lead to failure, and enables large seating forces without damaging the valve. Additionally, this valve design, even when used with large, high-pressure applications, does not require large conventional valve actuators and the valve stem itself is eliminated. Actuation is achieved with the use of a small, simple solenoid valve. This design also eliminates the need for many seals used with existing ball valve and globe valve designs, which commonly cause failure, too. This, coupled with the elimination of the valve stem and conventional valve actuator, improves valve reliability and seat life. Other mechanical liftoff seats have been designed; however, they have only resulted in increased cost, and incurred other reliability issues. With this novel design, the seat is lifted by simply removing the working fluid pressure that presses it against the seat and no external force is required. By eliminating variables associated with existing ball and globe configurations that can have damaging effects upon a valve, this novel design reduces downtime in rocket engine test schedules and maintenance costs.
Comparative study of oxihydrogen injection in turbocharged compression ignition engines
NASA Astrophysics Data System (ADS)
Barna, L.; Lelea, D.
2018-01-01
This document proposes for analysis, comparative study of the turbocharged, compression-ignition engine, equipped with EGR valve, operation in case the injection in intake manifold thereof a maximum flow rate of 1l/min oxyhydrogen resulted of water electrolysis, at two different injection pressures, namely 100 Pa and 3000 Pa, from the point of view of flue gas opacity. We found a substantial reduction of flue gas opacity in both cases compared to conventional diesel operation, but in different proportions.
SLM Produced Hermetically Sealed Isolation Valve
NASA Technical Reports Server (NTRS)
Richard, James
2014-01-01
Marshall Space Flight Center (MSFC) has developed a valve concept to replace traditional pyrotechnic-driven isolation valves. This paper will describe the valve design and development process. The valve design uses a stem/wedge to support a disk inside the valve. That disk hermetically seals the pressurized fluids. A release mechanism holds the stem/wedge and a large spring in place. When required to open, a solenoid is energized and pulls the release mechanism allowing the spring to pull the stem/wedge away from the disk. Now the disk is unsupported and the pressure ruptures the disk allowing flow to the outlet of the valve. This paper will provide details of this design, describe the development testing, and show the results from the valve level tests performed. Also, a trade study is presented to show the advantages of this design to a conventional pyrotechnic-based valve.
SLM Produced Hermetically Sealed Isolation Valve
NASA Technical Reports Server (NTRS)
Richard, James A.
2014-01-01
Marshall Space Flight Center (MSFC) has developed a valve concept to replace traditional pyrotechnic driven isolation valves. This paper will describe the valve design and development process. The valve design uses a stem/wedge to support a disk inside the valve. That disk hermetically seals the pressurized fluids. A release mechanism holds the stem/wedge and a large spring in place. When required to open, a solenoid is energized and pulls the release mechanism allowing the spring to pull the stem/wedge away from the disk. Now the disk is unsupported and the pressure ruptures the disk allowing flow to the outlet of the valve. This paper will provide details of this design, describe the development testing, and show the results from the valve level tests performed. Also, a trade study is presented to show the advantages of this design to a conventional pyrotechnic based valve.
Alkherayf, Fahad; Abou Al-Shaar, Hussam; Awad, Michael
2015-09-01
To evaluate the clinical outcomes and complications rate among idiopathic intracranial hypertension (IIH) patients who underwent lumboperitoneal (LP) shunt insertion with a programmable Strata valve. We retrospectively evaluated patients who underwent LP shunt with a programmable Strata valve insertion at the University of Ottawa Civic Hospital from November 2012 to June 2013. The demographic data, clinical symptoms, opening pressure, pre-operative and post-operative visual fields, neuroimaging, visual acuity, disc status, and complications were recorded and analyzed. Seven female patients with IIH underwent insertion of an LP shunt with a programmable Strata valve. The mean opening pressure was 35.8 cm H2O. The initial valve setting was 1.5, and four patients required post-operative valve pressure adjustment. All patients showed significant improvement in objective visual testing at follow-up as well as less frequent headaches. None of the patients developed intra- or post-operative complications. LP shunts with programmable Strata valve systems are a potential alternative to conventional LP and programmable ventriculoperitoneal shunt systems as well as optic nerve sheath fenestration, due to their potential in avoiding brain injury, lower failure and complication rates, lower intracranial hypotension incidence, and flexibility in adjusting valve pressure settings post-operatively evading under- and overdrainage complications. They should be considered for the management of IIH instead of early design LP systems and VP shunts. A randomized multi-center trial should be conducted to compare the efficacy of these surgical techniques. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Takizawa, Kuniharu
A novel three-dimensional (3-D) projection display used with polarized eyeglasses is proposed. It consists of polymer-dispersed liquid crystal-light valves that modulate the illuminated light based on light scattering, a polarization beam splitter, and a Schlieren projection system. The features of the proposed display include a 3-D image display with a single projector, half size and half power consumption compared with a conventional 3-D projector with polarized glasses. Measured electro-optic characteristics of a polymer-dispersed liquid-crystal cell inserted between crossed polarizers suggests that the proposed display achieves small cross talk and high-extinction ratio.
Vafaee, Tayyebeh; Thomas, Daniel; Desai, Amisha; Jennings, Louise M.; Berry, Helen; Rooney, Paul; Kearney, John; Fisher, John
2017-01-01
Abstract The clinical use of decellularized cardiac valve allografts is increasing. Long‐term data will be required to determine whether they outperform conventional cryopreserved allografts. Valves decellularized using different processes may show varied long‐term outcomes. It is therefore important to understand the effects of specific decellularization technologies on the characteristics of donor heart valves. Human cryopreserved aortic and pulmonary valved conduits were decellularized using hypotonic buffer, 0.1% (w/v) sodium dodecyl sulfate and nuclease digestion. The decellularized tissues were compared to cellular cryopreserved valve tissues using histology, immunohistochemistry, quantitation of total deoxyribose nucleic acid, collagen and glycosaminoglycan content, in vitro cytotoxicity assays, uniaxial tensile testing and subcutaneous implantation in mice. The decellularized tissues showed no histological evidence of cells or cell remnants and >97% deoxyribose nucleic acid removal in all regions (arterial wall, muscle, leaflet and junction). The decellularized tissues retained collagen IV and von Willebrand factor staining with some loss of fibronectin, laminin and chondroitin sulfate staining. There was an absence of major histocompatibility complex Class I staining in decellularized pulmonary valve tissues, with only residual staining in isolated areas of decellularized aortic valve tissues. The collagen content of the tissues was not decreased following decellularization however the glycosaminoglycan content was reduced. Only moderate changes in the maximum load to failure of the tissues were recorded postdecellularization. The decellularized tissues were noncytotoxic in vitro, and were biocompatible in vivo in a mouse subcutaneous implant model. The decellularization process will now be translated into a good manufacturing practices‐compatible process for donor cryopreserved valves with a view to future clinical use. Copyright © 2016 The Authors Tissue Engineering and Regenerative Medicine published by John Wiley & Sons, Ltd. PMID:27943656
Boudjemline, Younes
2018-01-01
To describe a new modification, the one-step procedure, that allows interventionists to pre-stent and implant a Melody valve simultaneously. Percutaneous pulmonary valve implantation (PPVI) is the standard of care for managing patients with dysfunctional right ventricular outflow tract, and the approach is standardized. Patients undergoing PPVI using the one-step procedure were identified in our database. Procedural data and radiation exposure were compared to those in a matched group of patients who underwent PPVI using the conventional two-step procedure. Between January 2016 and January 2017, PPVI was performed in 27 patients (median age/range, 19.1/10-55 years) using the one-step procedure involving manual crimping of one to three bare metal stents over the Melody valve. The stent and Melody valve were delivered successfully using the Ensemble delivery system. No complications occurred. All patients had excellent hemodynamic results (median/range post-PPVI right ventricular to pulmonary artery gradient, 9/0-20 mmHg). Valve function was excellent. Median procedural and fluoroscopic times were 56 and 10.2 min, respectively, which significantly differed from those of the two-step procedure group. Similarly, the dose area product (DAP), and radiation time were statistically lower in the one-step group than in the two-step group (P < 0.001 for all variables). After a median follow-up of 8 months (range, 3-14.7), no patient underwent reintervention, and no device dysfunction was observed. The one-step procedure is a safe modification that allows interventionists to prestent and implants the Melody valve simultaneously. It significantly reduces procedural and fluoroscopic times, and radiation exposure. © 2017 Wiley Periodicals, Inc.
Microfluidic valve array control system integrating a fluid demultiplexer circuit
NASA Astrophysics Data System (ADS)
Kawai, Kentaro; Arima, Kenta; Morita, Mizuho; Shoji, Shuichi
2015-06-01
This paper proposes an efficient control method for the large-scale integration of microvalves in microfluidic systems. The proposed method can control 2n individual microvalves with 2n + 2 control lines (where n is an integer). The on-chip valves are closed by applying pressure to a control line, similar to conventional pneumatic microvalves. Another control line closes gate valves between the control line to the on-chip valves and the on-chip valves themselves, to preserve the state of the on-chip valves. The remaining control lines select an activated gate valve. While the addressed gate valve is selected by the other control lines, the corresponding on-chip valve is actuated by applying input pressure to the control line to the on-chip valves. Using this method would substantially reduce the number of world-to-chip connectors and off-chip valve controllers. Experiments conducted using a fabricated 28 microvalve array device, comprising 256 individual on-chip valves controlled with 18 (2 × 8 + 2) control lines, yielded switching speeds for the selected on-chip valve under 90 ms.
Percutaneous repair or surgery for mitral regurgitation.
Feldman, Ted; Foster, Elyse; Glower, Donald D; Glower, Donald G; Kar, Saibal; Rinaldi, Michael J; Fail, Peter S; Smalling, Richard W; Siegel, Robert; Rose, Geoffrey A; Engeron, Eric; Loghin, Catalin; Trento, Alfredo; Skipper, Eric R; Fudge, Tommy; Letsou, George V; Massaro, Joseph M; Mauri, Laura
2011-04-14
Mitral-valve repair can be accomplished with an investigational procedure that involves the percutaneous implantation of a clip that grasps and approximates the edges of the mitral leaflets at the origin of the regurgitant jet. We randomly assigned 279 patients with moderately severe or severe (grade 3+ or 4+) mitral regurgitation in a 2:1 ratio to undergo either percutaneous repair or conventional surgery for repair or replacement of the mitral valve. The primary composite end point for efficacy was freedom from death, from surgery for mitral-valve dysfunction, and from grade 3+ or 4+ mitral regurgitation at 12 months. The primary safety end point was a composite of major adverse events within 30 days. At 12 months, the rates of the primary end point for efficacy were 55% in the percutaneous-repair group and 73% in the surgery group (P=0.007). The respective rates of the components of the primary end point were as follows: death, 6% in each group; surgery for mitral-valve dysfunction, 20% versus 2%; and grade 3+ or 4+ mitral regurgitation, 21% versus 20%. Major adverse events occurred in 15% of patients in the percutaneous-repair group and 48% of patients in the surgery group at 30 days (P<0.001). At 12 months, both groups had improved left ventricular size, New York Heart Association functional class, and quality-of-life measures, as compared with baseline. Although percutaneous repair was less effective at reducing mitral regurgitation than conventional surgery, the procedure was associated with superior safety and similar improvements in clinical outcomes. (Funded by Abbott Vascular; EVEREST II ClinicalTrials.gov number, NCT00209274.).
Dual mode fuel injection system and fuel injector for same
Lawrence, Keith E.; Tian, Ye
2005-09-20
A fuel injection system has the ability to produce two different spray patterns depending on the positioning of a needle control valve member. Positioning of the needle control valve member determines which of the two needle control chambers are placed in a low pressure condition. First and second needle valve members have closing hydraulic surfaces exposed to fluid pressure in the two needle control chambers. The injector preferably includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set controlled respectively, by the first and second needle valve members.
Profile of Heart Donors from the Human Valve Bank of the Santa Casa de Misericórdia de Curitiba
Ferreira, Renata Maria; da Costa, Marise Teresinha Brenner Affonso; Canciglieri Junior, Osiris; Sant'Anna, Ângelo Márcio Oliveira
2016-01-01
Introduction Human heart valves are used as replacement valves and have satisfactory functional results compared with conventional prostheses. Objective Characterize the profile of effective heart donors from the human valve bank of the santa casa de misericórdia de curitiba and analyze the association between the profile variables. Methods It consists of a retrospective and quantitative study of electronic medical records from heart donors for heart valves. every heart donation made to the bank between january 2004 and december 2014 was studied. Results 2,149 donations were analyzed, from donors aged 0 to 71 years old, with an average of 34.9 ± 15.03 years old. most donors were male 65.7% (n=1,411) and 34.3% (n=738) were female. among the most frequent causes of the donors' death are trauma at 53% (n=1,139) and cerebral vascular accident at 34.2% (n=735). there was significant statistical association between the analyzed variables. Conclusion There has been an improvement in brazil's donation rate, being essential that the tissue banks work together with the state and federal district centers for notification, procurement and distribution of organs in order to increase the number of donors. PMID:27556322
Malekzadeh-Milani, Sophie; Ladouceur, Magalie; Cohen, Sarah; Iserin, Laurence; Boudjemline, Younes
2014-11-01
Although widely accepted worldwide, indications for percutaneous valve replacement are limited to treatment of dysfunction of prosthetic conduits inserted in the right ventricular outflow tract (RVOT). There has been little evaluation of the use of the Melody(®) valve for patched non-circular pulmonary pathways. To evaluate the outcomes of Melody valve insertion in patients with a patched non-circular RVOT. We analysed procedural and outcomes data from 34 patients who underwent Melody valve implantation for a non-circular RVOT. RVOT preparation was done in all patients, using different techniques (conventional, Russian doll and/or PA jailing). Melody valve insertion was performed concomitantly in most patients. All procedures were successful. Sixteen patients had complex additional procedures, including the jailing technique (n=5), the Russian doll technique (n=6) and multiple stent implantations (Russian jailing; n=5). The remaining patients were treated using the conventional technique with systematic prestenting. Three early complications occurred: one haemoptysis; one residual RVOT obstruction needing recatheterization 48 hours after percutaneous pulmonary valve implantation; and one stent embolization during advancement of the Ensemble(®) delivery system. The mean follow-up period was 2.6 years postprocedure. There was no stent fracture, migration or embolization. Two patients developed a significant paraprosthetic leak and one received a second Melody valve. Careful patient selection, balloon sizing and RVOT preparation with prestenting are required to create a safe landing zone for the Melody valve. Short-term follow-up shows excellent results with no stent fracture or migration and appears promising. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Evolving Techniques for Mitral Valve Reconstruction
Galloway, Aubrey C.; Grossi, Eugene A.; Bizekis, Costas S.; Ribakove, Greg; Ursomanno, Patricia; Delianides, Julie; Baumann, F. Gregory; Spencer, Frank C.; Colvin, Stephen B.
2002-01-01
Objective To analyze the effectiveness of new techniques of mitral valve reconstruction (MVR) that have evolved over the last decade, such as aggressive anterior leaflet repair and minimally invasive surgery using an endoaortic balloon occluder. Summary Background Data MVR via conventional sternotomy has been an established treatment for mitral insufficiency for over 20 years, primarily for the treatment of patients with posterior leaflet prolapse. Methods Between June 1980 and June 2001, 1,195 consecutive patients had MVR with ring annuloplasty. Conventional sternotomy was used in 843 patients, minimally invasive surgery in 352 (since June 1996). Anterior leaflet repair was performed in 374 patients, with increasing use over the last 10 years. Follow-up was 100% complete (mean 4.6 years, range 0.5–20.5). Results Hospital mortality was 4.7% overall and 1.4% for isolated MVR (1.1% for minimally invasive surgery vs. 1.6% for conventional sternotomy;P = .4). Multivariate analysis showed the factors predictive of increased operative risk to be age, NYHA functional class, concomitant procedures, and previous cardiac surgery. The 5-year results for freedom from cardiac death, reoperation, and valve-related complications among the 782 patients with degenerative etiology are, respectively, as follows (P > .05 for all end points): for anterior leaflet repair, 93%, 94%, 90%; for no anterior leaflet repair, 91%, 92%, 91%; for minimally invasive surgery, 97%, 89%, 93%; and for conventional sternotomy, 93%, 94%, 90%. Conclusions These findings indicate that late results of MVR after minimally invasive surgery and after anterior leaflet repair are equivalent to those achievable with conventional sternotomy and posterior leaflet repair. These options significantly expand the range of patients suitable for mitral valve repair surgery and give further evidence to support wider use of minimally invasive techniques. PMID:12192315
Ariyaratnam, Priyadharshanan; Mclean, Lindsay A; Cale, Alexander; Chaudhry, Mubarak A; Vijayan, Ajith; Richards, Neil; Jarvis, Martin A; Haqzad, Yama; Ngaage, Dumbor; Cowen, Michael E; Loubani, Mahmoud
2018-02-14
Conventional cardiopulmonary bypass is the most commonly used means of artificial circulation in cardiac surgery. However, it suffers from the effects of haemodilution and activation of inflammatory/coagulation cascades. Prime displacement (PD) can offset haemodilution and Mini-Extracorporeal Technology (MIECT) can offset both. So far, no study has compared all of these modalities together; hence, we compared the outcomes of these 3 modalities at our institution. This was a retrospective analysis of our cardiac surgical database. A total of 9626 patients underwent conventional bypass (CB), 3125 patients underwent a modification of CB, called PD, and 904 underwent MIECT. A 1:1 propensity-matching algorithm was employed using IBM SPSS 24 to match (i) 813 MIECT patients with 813 CB patients and (ii) 717 MIECT patients with 717 PD patients. The patients included coronary artery bypass grafting and valve surgery. MIECT had significantly (P < 0.05) longer bypass and cross-clamp times compared to CB and PD. MIECT had significantly higher rates of postoperative atrial fibrillation associated with it compared to CB. The mean red cell blood transfusion was significantly lower in the MIECT group compared to the CB group as was the mean platelet transfusion and fresh frozen plasma transfusion. The overall 5-year survival was higher in the MIECT group compared to the CB group (log-rank, P = 0.018). Between the MIECT and the PD groups, we found the incidence of renal failure and gastrointestinal complications to be significantly higher in the PD group compared to the MIECT group. MIECT has short-term advantages over CB and PD. However, due to the retrospective limitations of the study, including calendar time bias, a multicentre randomized controlled trial comparing all 3 modalities will be beneficial for the larger cardiac community. © The Author(s) 2018. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Umakanthan, Ramanan; Petracek, Michael R; Leacche, Marzia; Solenkova, Nataliya V; Eagle, Susan S; Thompson, Annemarie; Ahmad, Rashid M; Greelish, James P; Ball, Stephen K; Hoff, Steven J; Absi, Tarek S; Balaguer, Jorge M; Byrne, John G
2010-03-01
The study aim was to determine the safety and benefits of minimally invasive mitral valve surgery without aortic cross-clamping for mitral valve surgery after previous cardiac surgery. Between January 2006 and August 2008, a total of 90 consecutive patients (38 females, 52 males; mean age 66 +/- 9 years) underwent minimally invasive mitral valve surgery after having undergone previous cardiac surgery. Of these patients, 80 (89%) underwent mitral valve replacement and 10 (11%) mitral valve repair utilizing a small (5 cm) right lateral thoracotomy along the 4th or 5th intercostal space under fibrillatory arrest (mean temperature 28 +/- 2 degrees C). The predicted mortality, calculated using the Society of Thoracic Surgeons (STS) algorithm, was compared to the observed mortality. The mean ejection fraction was 45 +/- 13%, mean NYHA class 3 +/- 1, while 66 patients (73%) had previous coronary artery bypass grafting and 37 (41%) had previous valve surgery. Twenty-six patients (29%) underwent non-elective surgery. Cardiopulmonary bypass was instituted through axillary (n = 19), femoral (n = 70) or direct use aortic (n = 1) cannulation. Operative mortality was 2% (2/90), lower than the STS-predicted mortality of 7%. Three patients (3%) developed acute renal failure postoperatively, one patient (1%) required new-onset hemodialysis, and one (1%) developed postoperative stroke. No patients developed postoperative myocardial infarction. The mean postoperative packed red blood cell transfusion requirement at 48 h was 2 +/- 3 units. Minimally invasive right thoracotomy without aortic cross-clamping is an excellent alternative to conventional redo-sternotomy for reoperative mitral valve surgery. The present study confirmed that this technique is safe and effective in reducing operative mortality in high-risk patients undergoing reoperative cardiac surgery.
Chen, C Y; Yu, D L; Feng, B B; Yao, L H; Song, X M; Zang, L G; Gao, X Y; Yang, Q W; Duan, X R
2016-09-01
On HL-2A tokamak, supersonic molecular beam injection (SMBI) has been developed as a routine refueling method. The key components of the system are an electromagnetic valve and a conic nozzle. The valve and conic nozzle are assembled to compose the simplified Laval nozzle for generating the pulsed beam. The appurtenance of the system includes the cooling system serving the cooled SMBI generation and the in situ calibration component for quantitative injection. Compared with the conventional gas puffing, the SMBI features prompt response and larger fueling flux. These merits devote the SMBI a good fueling method, an excellent plasma density feedback control tool, and an edge localized mode mitigation resource.
Jana, Soumen; Lerman, Amir
2015-12-01
Heart valve tissue engineering could be a possible solution for the limitations of mechanical and biological prostheses, which are commonly used for heart valve replacement. In tissue engineering, cells are seeded into a 3-dimensional platform, termed the scaffold, to make the engineered tissue construct. However, mimicking the mechanical and spatial heterogeneity of a heart valve structure in a fabricated scaffold with uniform cell distribution is daunting when approached conventionally. Bioprinting is an emerging technique that can produce biological products containing matrix and cells, together or separately with morphological, structural and mechanical diversity. This advance increases the possibility of fabricating the structure of a heart valve in vitro and using it as a functional tissue construct for implantation. This review describes the use of bioprinting technology in heart valve tissue engineering. Copyright © 2015 Elsevier Inc. All rights reserved.
Vacuum-assisted venous return reduces blood usage.
Banbury, Michael K; White, Jennifer A; Blackstone, Eugene H; Cosgrove, Delos M
2003-09-01
To determine whether vacuum-assisted venous return has clinical advantages over conventional gravity drainage apart from allowing the use of smaller cannulas and shorter tubing. A total of 150 valve operations were performed at our institution between February and July 1999 using vacuum-assisted venous return with small venous cannulas connected to short tubing. These were compared with (1) 83 valve operations performed between April 1997 and January 1998 using the initial version of vacuum-assisted venous return, and (2) 124 valve operations performed between January and April of 1997 using conventional gravity drainage. Priming volume, hematocrit value, red blood cell usage, and total blood product usage were compared multivariably. These comparisons were covariate and propensity adjusted for dissimilarities between the groups and confirmed by propensity-matched pairs analysis. Priming volume was 1.4 +/- 0.4 L for small-cannula vacuum-assisted venous return, 1.7 +/- 0.4 L for initial vacuum-assisted venous return, and 2.0 +/- 0.4 L for gravity drainage (P <.0001). Smaller priming resulted in higher hematocrit values both at the beginning of cardiopulmonary bypass (27% +/- 5% compared with 26% +/- 4% and 25% +/- 4%, respectively, P <.0001) and at the end (30% +/- 4% compared with 28% +/- 4% and 27% +/- 4%, respectively, P <.0001). Red cell transfusions were used in 17% of the patients having small-cannula vacuum-assisted venous return, 27% of the initial patients having vacuum-assisted venous return, and 37% of the patients having gravity drainage (P =.001); total blood product usage was 19%, 27%, and 39%, respectively (P =.002). Although ministernotomy also was associated with reduced blood product usage (P <.004), propensity matching on type of sternotomy confirmed the association of vacuum-assisted venous return with lowered blood product usage. Vacuum-assisted venous return results in (1) higher hematocrit values during cardiopulmonary bypass and (2) decreased red cell and total blood product usage.
Nonlinear dynamic modeling for smart material electro-hydraulic actuator development
NASA Astrophysics Data System (ADS)
Larson, John P.; Dapino, Marcelo J.
2013-03-01
Smart material electro-hydraulic actuators use hydraulic rectification by one-way check valves to amplify the motion of smart materials, such as magnetostrictives and piezoelectrics, in order to create compact, lightweight actuators. A piston pump driven by a smart material is combined with a hydraulic cylinder to form a self-contained, power-by-wire actuator that can be used in place of a conventional hydraulic system without the need for hydraulic lines and a centralized pump. The performance of an experimental actuator driven by a 12.7 mm diameter, 114 mm length Terfenol-D rod is evaluated over a range of applied input frequencies, loads, and currents. The peak performance achieved is 37 W, moving a 220 N load at a rate of 17 cm/s and producing a blocked pressure of 12.5 MPa. Additional tests are conducted to quantify the dynamic behavior of the one-way reed valves using a scanning laser vibrometer to identify the frequency response of the reeds and the effect of the valve seat and fluid mass loading. A lumped-parameter model is developed for the system that includes valve inertia and fluid response nonlinearities, and the model results are compared with the experimental data.
Simple repair approach for mitral regurgitation in Barlow disease.
Ben Zekry, Sagit; Spiegelstein, Dan; Sternik, Leonid; Lev, Innon; Kogan, Alexander; Kuperstein, Rafael; Raanani, Ehud
2015-11-01
Mitral valve repair for myxomatous Barlow disease is a challenging procedure requiring complex surgery with less than optimal results. The use of ring-only repair has been previously reported but never analyzed or followed-up. We investigated this simple valve repair approach for patients with Barlow disease and multisegment involvement causing mainly central jet. Of 572 patients who underwent mitral valve repair for mitral regurgitation at our medical center, 24 with Barlow disease (aged 47 ± 14 years; 46% male) underwent ring-only repair. Patients were characterized by severely enlarged mitral valve annulus, multisegment prolapse involving both leaflets, and demonstrated mainly a central wide regurgitant jet. Surgical technique included only the implantation of a large mitral annuloplasty ring. Early and late outcome results were compared with those of the remaining patients who underwent conventional mitral valve repair for degenerative disease (controls). All ring-only patients presented with moderate-severe/severe mitral regurgitation (vena contracta, 0.6 ± 0.1 cm; regurgitation volume, 52 ± 17 mL), with mainly a central jet and almost preserved ejection fraction (59% ± 6%). Cardiopulmonary bypass and crossclamp times were significantly shorter compared with controls (P < .0001). At follow-up (ring-only, 38 ± 36 months and controls, 36 ± 29 months), there were no late deaths in the ring-only group compared with 19 (4%) in the controls. Late follow-up revealed New York Heart Association functional class I or II in 95% of ring-only patients, compared with 90% of controls. Freedom from recurrent moderate or severe mitral regurgitation was 100% and 89% in the ring-only and control groups, respectively. Mitral annuloplasty for Barlow disease patients with multisegment involvement and mainly central regurgitant jet is both simple and reproducible with excellent late outcomes. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
How to Perform Transcaval Access and Closure for Transcatheter Aortic Valve Implantation
Lederman, Robert J.; Babaliaros, Vasilis C.; Greenbaum, Adam B.
2016-01-01
Transcaval, or caval-aortic, access is a promising approach for fully percutaneous trans-catheter aortic valve implantation in patients without good conventional access options. This tutorial review provides step-by-step guidance to planning and executing the procedure, along with approaches to remedy complications. PMID:26356244
Thermal and mechanical analysis of major components for the advanced adiabatic diesel engine
NASA Technical Reports Server (NTRS)
1983-01-01
The proposed design for the light duty diesel is an in-line four cylinder spark assisted diesel engine mounted transversely in the front of the vehicle. The engine has a one piece cylinder head, with one intake valve and one exhaust valve per cylinder. A flat topped piston is used with a cylindrical combustion chamber recessed into the cylinder head directly under the exhaust valve. A single ceramic insert is cast into the cylinder head to insulate both the combustion chamber and the exhaust port. A similar ceramic insert is cast into the head to insulate the intake port. A ceramic faceplate is pressed into the combustion face of the head to insulate the face of the head from hot combustion gas. The valve seats are machined directly into the ceramic faceplate for the intake valve and into the ceramic exhaust pot insert for the exhaust valve. Additional ceramic applications in the head are the use of ceramic valve guides and ceramic insulated valves. The ceramic valve guides are press fit into the head and are used for increased wear resistance. The ceramic insulated valves are conventional valves with the valve faces plasma spray coated with ceramic for insulation.
Modelling and study of active vibration control for off-road vehicle
NASA Astrophysics Data System (ADS)
Zhang, Junwei; Chen, Sizhong
2014-05-01
In view of special working characteristics and structure, engineering machineries do not have conventional suspension system typically. Consequently, operators have to endure severe vibrations which are detrimental both to their health and to the productivity of the loader. Based on displacement control, a kind of active damping method is developed for a skid-steer loader. In this paper, the whole hydraulic system for active damping method is modelled which include swash plate dynamics model, proportional valve model, piston accumulator model, pilot-operated check valve model, relief valve model, pump loss model, and cylinder model. A new road excitation model is developed for the skid-steer loader specially. The response of chassis vibration acceleration to road excitation is verified through simulation. The simulation result of passive accumulator damping is compared with measurements and the comparison shows that they are close. Based on this, parallel PID controller and track PID controller with acceleration feedback are brought into the simulation model, and the simulation results are compared with passive accumulator damping. It shows that the active damping methods with PID controllers are better in reducing chassis vibration acceleration and pitch movement. In the end, the test work for active damping method is proposed for the future work.
Lemcke, J; Meier, U; Müller, C; Fritsch, M; Eymann, R; Kiefer, M; Kehler, U; Langer, N; Rohde, V; Ludwig, H-Ch; Weber, F; Remenez, V; Schuhmann, M; Stengel, D
2010-01-01
Overdrainage is a common complication observed after shunting patients with idiopathic normal-pressure hydrocephalus (iNPH), with an estimated incidence up to 25%. Gravitational units that counterbalance intracranial pressure changes were developed to overcome this problem. We will set out to investigate whether the combination of a programmable valve and a gravitational unit (proGAV, Aesculap/Miethke, Germany) is capable of reducing the incidence of overdrainage and improving patient-centered outcomes compared to a conventional programmable valve (Medos-Codman, Johnson & Johnson, Germany). SVASONA is a pragmatic randomized controlled trial conducted at seven centers in Germany. Patients with a high probability of iNPH (based on clinical signs and symptoms, lumbar infusion and/or tap test, cranial computed tomography [CCT]) and no contraindications for surgical drainage will randomly be assigned to receive (1) a shunt assistant valve (proGAV) or (2) a conventional, programmable shunt valve (programmable Medos-Codman).We will test the primary hypothesis that the experimental device reduces the rate of overdrainage from 25% to 10%. As secondary analyses, we will measure iNPH-specific outcomes (i.e., the Black grading scale and the NPH Recovery Rate), generic quality of life (Short Form 36), and complications and serious adverse events (SAE). One planned interim analysis for safety and efficacy will be performed halfway through the study. To detect the hypothesized difference in the incidence of overdrainage with a type I error of 5% and a type II error of 20%, correcting for multiple testing and an anticipated dropout rate of 10%, 200 patients will be enrolled.The presented trial is currently recruiting patients, with the first results predicted to be available in late 2008.
Dugernier, Jonathan; Hesse, Michel; Vanbever, Rita; Depoortere, Virginie; Roeseler, Jean; Michotte, Jean-Bernard; Laterre, Pierre-François; Jamar, François; Reychler, Gregory
2017-02-01
To compare in vivo the total and regional pulmonary deposition of aerosol particles generated by a new system combining a vibrating-mesh nebulizer with a specific valved holding chamber and constant-output jet nebulizer connected to a corrugated tube. Cross-over study comparing aerosol delivery to the lungs using two nebulizers in 6 healthy male subjects: a vibrating-mesh nebulizer combined with a valved holding chamber (Aerogen Ultra®, Aerogen Ltd., Galway, Ireland) and a jet nebulizer connected to a corrugated tube (Opti-Mist Plus Nebulizer®, ConvaTec, Bridgewater, NJ). Nebulizers were filled with diethylenetriaminepentaacetic acid labelled with technetium-99 m ( 99m Tc-DTPA, 2 mCi/4 mL). Pulmonary deposition of 99m Tc-DTPA was measured by single-photon emission computed tomography combined with a low dose CT-scan (SPECT-CT). Pulmonary aerosol deposition from SPECT-CT analysis was six times increased with the vibrating-mesh nebulizer as compared to the jet nebulizer (34.1 ± 6.0% versus 5.2 ± 1.1%, p < 0.001). However, aerosol penetration expressed as the three-dimensional normalized ratio of the outer and the inner regions of the lungs was similar between both nebulizers. This study demonstrated the high superiority of the new system combining a vibrating-mesh nebulizer with a valved holding chamber to deliver nebulized particles into the lungs as comparted to a constant-output jet nebulizer with a corrugated tube.
Development of Overflow-Prevention Valve with Trigger Mechanism.
NASA Astrophysics Data System (ADS)
Ishino, Yuji; Mizuno, Takeshi; Takasaki, Masaya
2016-09-01
A new overflow-prevention valve for combustible fluid is developed which uses a trigger mechanism. Loading arms for combustible fluid are used for transferring oil from a tanker to tanks and vice versa. The loading arm has a valve for preventing overflow. Overflow- prevention valves cannot use any electric component to avoid combustion. Therefore, the valve must be constructed only by mechanical parts. The conventional overflow-prevention valve uses fluid and pneumatic forces. It consists of a sensor probe, a cylinder, a main valve for shutting off the fluid and a locking mechanism for holding an open state of the main valve. The proposed overflow-prevention valve uses the pressure due to the height difference between the fluid level of the tank and the sensor probe. However, the force of the cylinder produced by the pressure is too small to release the locking mechanism. Therefore, a trigger mechanism is introduced between the cylinder and the locking mechanism. The trigger mechanism produces sufficient force to release the locking mechanism and close the main valve when the height of fluid exceeds a threshold value. A trigger mechanism is designed and fabricated. The operation necessary for closing the main valve is conformed experimentally.
NASA Technical Reports Server (NTRS)
Tucker, Curtis E., Jr.; Sherrit, Stewart
2011-01-01
For commercial, military, and aerospace applications, low-cost, small, reliable, and lightweight gas and liquid hermetically sealed valves with post initiation on/off capability are highly desirable for pressurized systems. Applications include remote fire suppression, single-use system-pressurization systems, spacecraft propellant systems, and in situ instruments. Current pyrotechnic- activated rupture disk hermetic valves were designed for physically larger systems and are heavy and integrate poorly with portable equipment, aircraft, and small spacecraft and instrument systems. Additionally, current pyrotechnically activated systems impart high g-force shock loads to surrounding components and structures, which increase the risk of damage and can require additional mitigation. The disclosed mechanism addresses the need for producing a hermetically sealed micro-isolation valve for low and high pressure for commercial, aerospace, and spacecraft applications. High-precision electrical discharge machining (EDM) parts allow for the machining of mated parts with gaps less than a thousandth of an inch. These high-precision parts are used to support against pressure and extrusion, a thin hermetically welded diaphragm. This diaphragm ruptures from a pressure differential when the support is removed and/or when the plunger is forced against the diaphragm. With the addition of conventional seals to the plunger and a two-way actuator, a derivative of this design would allow nonhermetic use as an on/off or metering valve after the initial rupturing of the hermetic sealing disk. In addition, in a single-use hermetically sealed isolation valve, the valve can be activated without the use of potential leak-inducing valve body penetrations. One implementation of this technology is a high-pressure, high-flow-rate rupture valve that is self-rupturing, which is advantageous for high-pressure applications such as gas isolation valves. Once initiated, this technology is self-energizing and requires low force compared to current pyrotechnic-based burst disk hermetic valves. This is a novel design for producing a single-use, self-rupturing, hermetically sealed valve for isolation of pressurized gas and/or liquids. This design can also be applied for single-use disposable valves for chemical instruments. A welded foil diaphragm is fully supported by two mated surfaces that are machined to micron accuracies using EDM. To open the valve, one of the surfaces is moved relative to the other to (a) remove the support creating an unsupported diaphragm that ruptures due to over pressure, and/or (b) produce tension in the diaphragm and rupture it.
Numerical Simulation of Flow in Fluidic Valves in Rotating Detonation Engines
NASA Astrophysics Data System (ADS)
Gopalakrishnan, Nandini
Rotating detonation engines (RDE) have received considerable research attention in recent times for use in propulsion systems. The cycle frequency of operation of an RDE can be as high as 10,000 Hz. Conventional mechanical valves cannot operate at such high frequencies, leading to the need for propellant injectors or valves with no moving parts. A fluidic valve is such a valve and is the focus of this study. The valve consists of an orifice connected to a constant area plenum cavity which operates at constant pressure. The fluidic valve supplies propellants to the detonation tube through the orifice. Hydrogen - oxygen detonation is studied in a tube with fluidic valves. A detailed 19-step chemical reaction mechanism has been used to model detonation and the flow simulated in ANSYS Fluent. This research aims to determine the location of contact surface in the cavity and the time taken for the contact surface to leave the valve after a shock wave has passed through it. This will help us understand if the steady-state flow in the cavity is comprised of detonation products or fresh propellants.
Intracardiac echocardiography to diagnose pannus formation after aortic valve replacement.
Yamamoto, Yoshiya; Ohara, Takahiro; Funada, Akira; Takahama, Hiroyuki; Amaki, Makoto; Hasegawa, Takuya; Sugano, Yasuo; Kanzaki, Hideaki; Anzai, Toshihisa
2016-03-01
A 66-year-old female, under regular follow-up for 20 years after aortic valve replacement (19-mm Carbomedics), presented dyspnea on effort and hypotension during hemodialysis. A transthoracic echocardiogram showed elevation of transvalvular velocity up to 4 m/s, but the structure around the aortic prosthesis was difficult to observe due to artifacts. Fluoroscopy revealed normal motion of the leaflets of the mechanical valve. Intracardiac echocardiography (ICE) revealed a pannus-like structure in the left ventricular outflow tract. Transesophageal echocardiogram also revealed this structure. ICE can visualize structural abnormalities around a prosthetic valve after cardiac surgery even in patients in whom conventional imaging modalities failed.
Krackhardt, Florian; Kherad, Behrouz; Krisper, Maximilian; Pieske, Burkert; Laule, Michael; Tschöpe, Carsten
2017-01-01
Conduction disturbances requiring permanent pacemaker implantation following transcatheter aortic valve replacement (TAVR) are a common problem. Pacemaker implantation rates after TAVR appear to be higher compared to conventional aortic valve replacement. The aim of this study was to analyze whether a high annulus implantation conveys the benefit of a decreased rate of permanent pacemaker implantation while being safe and successful according to Valve Academic Research Consortium 2 (VARC2)-criteria. A total of 23 patients with symptomatic severe aortic valve stenosis, an aortic annulus of 19-27 mm and at high risk for surgery were treated with the Lotus valve. In all patients the valve was implanted in a high annulus position via femoral access. The primary device performance endpoint was VARC2-defined device success after 30 days and the primary safety endpoint was the need for permanent pacemaker implantation. The mean age was 73.23 ± 7.65 years, 46% were female, 38% were New York Heart Association class III/IV at baseline. Thirty-day follow-up data were available for all patients. The VARC2-defined device success rate after 30 days was 22/23 (96%). 2/21 (10%) patients required a newly implanted pacemaker due to 3rd degree atrioventricular block. 25% of the patients developed a new left bundle branch block after valvuloplasty or device implantation. 21 of the 23 patients (96%) had no other signs of conduction disturbances after 30 days. The approach of the modified implantation technique of Lotus TAVR device was safe and effective. The incidence of need for a permanent pacemaker following TAVR could be significantly reduced due to adopted implantation protocol.
Wijeysundera, Harindra C; Wong, William W L; Bennell, Maria C; Fremes, Stephen E; Radhakrishnan, Sam; Peterson, Mark; Ko, Dennis T
2014-10-01
There is increasing demand for transcatheter aortic valve replacement (TAVR) as the primary treatment option for patients with severe aortic stenosis who are high-risk surgical candidates or inoperable. We used mathematical simulation models to estimate the hypothetical effectiveness of TAVR with increasing wait times. We applied discrete event modelling, using data from the Placement of Aortic Transcatheter Valves (PARTNER) trials. We compared TAVR with medical therapy in the inoperable cohort, and compared TAVR to conventional aortic valve surgery in the high-risk cohort. One-year mortality and wait-time deaths were calculated in different scenarios by varying TAVR wait times from 10 days to 180 days, while maintaining a constant wait time for surgery at a mean of 15.6 days. In the inoperable cohort, the 1-year mortality for medical therapy was 50%. When the TAVR wait time was 10 days, the TAVR wait-time mortality was 1.9% with a 1-year mortality of 31.5%. TAVR wait-time deaths increased to 28.9% with a 180-day wait, with a 1-year mortality of 41.4%. In the high-risk cohort, the wait-time deaths and 1-year mortality for the surgical patients were 2.5% and 27%, respectively. The TAVR wait-time deaths increased from 2.2% with a 10-day wait to 22.4% with a 180-day wait, and a corresponding increase in 1-year mortality from 24.5% to 32.6%. Mortality with TAVR exceeded surgery when TAVR wait times exceeded 60 days. Modest increases in TAVR wait times have a substantial effect on the effectiveness of TAVR in inoperable patients and high-risk surgical candidates. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Beating heart mitral valve repair with integrated ultrasound imaging
NASA Astrophysics Data System (ADS)
McLeod, A. Jonathan; Moore, John T.; Peters, Terry M.
2015-03-01
Beating heart valve therapies rely extensively on image guidance to treat patients who would be considered inoperable with conventional surgery. Mitral valve repair techniques including the MitrClip, NeoChord, and emerging transcatheter mitral valve replacement techniques rely on transesophageal echocardiography for guidance. These images are often difficult to interpret as the tool will cause shadowing artifacts that occlude tissue near the target site. Here, we integrate ultrasound imaging directly into the NeoChord device. This provides an unobstructed imaging plane that can visualize the valve lea ets as they are engaged by the device and can aid in achieving both a proper bite and spacing between the neochordae implants. A proof of concept user study in a phantom environment is performed to provide a proof of concept for this device.
Fabricating microfluidic valve master molds in SU-8 photoresist
NASA Astrophysics Data System (ADS)
Dy, Aaron J.; Cosmanescu, Alin; Sluka, James; Glazier, James A.; Stupack, Dwayne; Amarie, Dragos
2014-05-01
Multilayer soft lithography has become a powerful tool in analytical chemistry, biochemistry, material and life sciences, and medical research. Complex fluidic micro-circuits require reliable components that integrate easily into microchips. We introduce two novel approaches to master mold fabrication for constructing in-line micro-valves using SU-8. Our fabrication techniques enable robust and versatile integration of many lab-on-a-chip functions including filters, mixers, pumps, stream focusing and cell-culture chambers, with in-line valves. SU-8 created more robust valve master molds than the conventional positive photoresists used in multilayer soft lithography, but maintained the advantages of biocompatibility and rapid prototyping. As an example, we used valve master molds made of SU-8 to fabricate PDMS chips capable of precisely controlling beads or cells in solution.
Nano-fabricated size exclusion chromatograph
NASA Technical Reports Server (NTRS)
Svehla, D.; Feldman, S.; Feldman, J.; Grunthaner, F.; Shakkottai, P.; Castillo, L. del; White, V.
2002-01-01
This paper describes the development of a nano-fabricated size exclusion chromatograph (nSEC) based on the principle that molecules traveling through amicrocolumn containing nano-fabricated features will have characteristic elution times that directly correlate to molecular weight. Compared to conventional size exclusion chromatography, the nSEC offers greater control over the size exclusion process; mass fabrication; integration of the separation column with associated valves, pumps, and detectors; and dramatic reductions in instrument mass and power requirements.
Starinieri, Pascal; Declercq, Peter E; Robic, Boris; Yilmaz, Alaaddin; Van Tornout, Michiel; Dubois, Jasperina; Mees, Urbain; Hendrikx, Marc
2017-07-01
Even though results have been encouraging, an unequivocal conclusion on the beneficial effect of minimally invasive extracorporeal circulation (MiECC) in patients undergoing aortic valve surgery cannot be derived from previous publications. Long-term outcomes are rarely reported and a significant decrease in operative mortality has not been shown. Most studies have a limited number of patients and are underpowered. They merely report on short-term results of a heterogeneous intraoperative group using different types of ECC system in aortic valve surgery. The aim of the present study was to determine whether MiECC systems are more beneficial than conventional extracorporeal systems (CECC) with regard to mortality, hospital stay and inflammation and with only haemodilution and blood-air interface as differences. We retrospectively analysed data regarding mortality, hospital stay and inflammation in patients undergoing isolated aortic valve surgery. Forty patients were divided into two groups based on the type of extracorporeal system used; conventional (n=20) or MiECC (n=20). Perioperative blood product requirements were significantly lower in the MiECC group (MiECC: 0.2±0.5 units vs CECC: 0.9±1.2 units, p=0.004). No differences were seen postoperatively regarding mortality (5% vs 5%, p=0.99), total length of hospital stay (10.6±7.2 days (MiECC) vs 12.1±5.9 days (CECC), p=0.39) or inflammation markers (CRP: MiECC: 7.09±13.62 mg/L vs CECC: 3.4±3.2 mg/L, p=0.89). MiECC provides circulatory support that is equally safe and feasible as conventional extracorporeal circuits. No differences in mortality, hospital stay or inflammation markers were observed.
Anterolateral minithoracotomy versus median sternotomy for mitral valve disease: a meta-analysis.
Ding, Chao; Jiang, Da-ming; Tao, Kai-yu; Duan, Qun-jun; Li, Jie; Kong, Min-jian; Shen, Zhong-hua; Dong, Ai-qiang
2014-06-01
Mitral valve disease tends to be treated with anterolateral minithoracotomy (ALMT) rather than median sternotomy (MS), as ALMT uses progressively smaller incisions to promote better cosmetic outcomes. This meta-analysis quantifies the effects of ALMT on surgical parameters and post-operative outcomes compared with MS. One randomized controlled study and four case-control studies, published in English from January 1996 to January 2013, were identified and evaluated. ALMT showed a significantly longer cardiopulmonary bypass time (P=0.001) and aortic cross-clamp time (P=0.05) compared with MS. However, the benefits of ALMT were evident as demonstrated by a shorter length of hospital stay (P<0.00001). According to operative complications, the onset of new arrhythmias following ALMT decreased significantly as compared with MS (P=0.05); however, the incidence of peri-operative mortality (P=0.62), re-operation for bleeding (P=0.37), neurologic events (P=0.77), myocardial infarction (P=0.84), gastrointestinal complications (P=0.89), and renal insufficiency (P=0.67) were similar to these of MS. Long-term follow-up data were also examined, and revealed equivalent survival and freedom from mitral valve events. Current clinical data suggest that ALMT is a safe and effective alternative to the conventional approach and is associated with better short-term outcomes and a trend towards longer survival.
Anterolateral minithoracotomy versus median sternotomy for mitral valve disease: a meta-analysis
Ding, Chao; Jiang, Da-ming; Tao, Kai-yu; Duan, Qun-jun; Li, Jie; Kong, Min-jian; Shen, Zhong-hua; Dong, Ai-qiang
2014-01-01
Objective: Mitral valve disease tends to be treated with anterolateral minithoracotomy (ALMT) rather than median sternotomy (MS), as ALMT uses progressively smaller incisions to promote better cosmetic outcomes. This meta-analysis quantifies the effects of ALMT on surgical parameters and post-operative outcomes compared with MS. Methods: One randomized controlled study and four case-control studies, published in English from January 1996 to January 2013, were identified and evaluated. Results: ALMT showed a significantly longer cardiopulmonary bypass time (P=0.001) and aortic cross-clamp time (P=0.05) compared with MS. However, the benefits of ALMT were evident as demonstrated by a shorter length of hospital stay (P<0.00001). According to operative complications, the onset of new arrhythmias following ALMT decreased significantly as compared with MS (P=0.05); however, the incidence of peri-operative mortality (P=0.62), re-operation for bleeding (P=0.37), neurologic events (P=0.77), myocardial infarction (P=0.84), gastrointestinal complications (P=0.89), and renal insufficiency (P=0.67) were similar to these of MS. Long-term follow-up data were also examined, and revealed equivalent survival and freedom from mitral valve events. Conclusions: Current clinical data suggest that ALMT is a safe and effective alternative to the conventional approach and is associated with better short-term outcomes and a trend towards longer survival. PMID:24903989
Magnon Valve Effect between Two Magnetic Insulators.
Wu, H; Huang, L; Fang, C; Yang, B S; Wan, C H; Yu, G Q; Feng, J F; Wei, H X; Han, X F
2018-03-02
The key physics of the spin valve involves spin-polarized conduction electrons propagating between two magnetic layers such that the device conductance is controlled by the relative magnetization orientation of two magnetic layers. Here, we report the effect of a magnon valve which is made of two ferromagnetic insulators (YIG) separated by a nonmagnetic spacer layer (Au). When a thermal gradient is applied perpendicular to the layers, the inverse spin Hall voltage output detected by a Pt bar placed on top of the magnon valve depends on the relative orientation of the magnetization of two YIG layers, indicating the magnon current induced by the spin Seebeck effect at one layer affects the magnon current in the other layer separated by Au. We interpret the magnon valve effect by the angular momentum conversion and propagation between magnons in two YIG layers and conduction electrons in the Au layer. The temperature dependence of the magnon valve ratio shows approximately a power law, supporting the above magnon-electron spin conversion mechanism. This work opens a new class of valve structures beyond the conventional spin valves.
Magnon Valve Effect between Two Magnetic Insulators
NASA Astrophysics Data System (ADS)
Wu, H.; Huang, L.; Fang, C.; Yang, B. S.; Wan, C. H.; Yu, G. Q.; Feng, J. F.; Wei, H. X.; Han, X. F.
2018-03-01
The key physics of the spin valve involves spin-polarized conduction electrons propagating between two magnetic layers such that the device conductance is controlled by the relative magnetization orientation of two magnetic layers. Here, we report the effect of a magnon valve which is made of two ferromagnetic insulators (YIG) separated by a nonmagnetic spacer layer (Au). When a thermal gradient is applied perpendicular to the layers, the inverse spin Hall voltage output detected by a Pt bar placed on top of the magnon valve depends on the relative orientation of the magnetization of two YIG layers, indicating the magnon current induced by the spin Seebeck effect at one layer affects the magnon current in the other layer separated by Au. We interpret the magnon valve effect by the angular momentum conversion and propagation between magnons in two YIG layers and conduction electrons in the Au layer. The temperature dependence of the magnon valve ratio shows approximately a power law, supporting the above magnon-electron spin conversion mechanism. This work opens a new class of valve structures beyond the conventional spin valves.
First-principles study of spin-transfer torque in Co{sub 2}MnSi/Al/Co{sub 2}MnSi spin-valve
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tang, Ling, E-mail: lingtang@zjut.edu.cn; Yang, Zejin, E-mail: zejinyang@zjut.edu.cn
The spin-transfer torque (STT) in Co{sub 2}MnSi(CMS)/Al/Co{sub 2}MnSi spin-valve system with and without interfacial disorder is studied by a first-principles noncollinear wave-function-matching method. It is shown that in the case of clean interface the angular dependence of STT for CoCo/Al (the asymmetry parameter Λ≈4.5) is more skewed than that for MnSi/Al (Λ≈2.9), which suggests the clean CoCo/Al architecture is much more efficient for the application on radio frequency oscillation. We also find that even with interfacial disorder the spin-valve of half-metallic CMS still has a relatively large parameter Λ compared to that of conventional ferromagnet. In addition, for clean interfacemore » the in-plane torkance of MnSi/Al is about twice as large as that of CoCo/Al. However, as long as the degree of interfacial disorder is sufficiently large, the CoCo/Al and MnSi/Al will show approximately the same magnitude of in-plane torkance. Furthermore, our results demonstrate that CMS/Al/CMS system has very high efficiency of STT to switch the magnetic layer of spin-valve.« less
Garg, Aatish; Parashar, Akhil; Agarwal, Shikhar; Aksoy, Olcay; Hammadah, Muhammad; Poddar, Kanhaiya Lal; Puri, Rishi; Svensson, Lars G; Krishnaswamy, Amar; Tuzcu, E Murat; Kapadia, Samir R
2015-02-15
The SAPIEN-XT is a newer generation balloon-expandable valve created of cobalt chromium frame, as opposed to the stainless steel frame used in the older generation SAPIEN valve. We sought to determine if there was difference in acute recoil between the two valves. All patients who underwent transfemoral-transcatheter aortic valve replacement using the SAPIEN-XT valve at the Cleveland Clinic were included. Recoil was measured using biplane cine-angiographic image analysis of valve deployment. Acute recoil was defined as [(valve diameter at maximal balloon inflation) - (valve diameter after deflation)]/valve diameter at maximal balloon inflation (reported as percentage). Patients undergoing SAPIEN valve implantation were used as the comparison group. Among the 23 mm valves, the mean (standard deviation-SD) acute recoil was 2.77% (1.14) for the SAPIEN valve as compared to 3.75% (1.52) for the SAPIEN XT valve (P = 0.04). Among the 26 mm valves, the mean (SD) acute recoil was 2.85% (1.4) for the SAPIEN valve as compared to 4.32% (1.63) for the SAPIEN XT valve (P = 0.01). Multivariable linear regression analysis demonstrated significantly greater adjusted recoil in the SAPIEN XT valves as compared to the SAPIEN valves by 1.43% [(95% CI: 0.69-2.17), P < 0.001]. However, the residual peak gradient was less for SAPIEN XT compared to SAPIEN valves [18.86 mm Hg versus 23.53 mm Hg (P = 0.01)]. Additionally, no difference in paravalvular leak was noted between the two valve types (P = 0.78). The SAPIEN XT valves had significantly greater acute recoil after deployment compared to the SAPIEN valves. Implications of this difference in acute recoil on valve performance need to be investigated in future studies. © 2014 Wiley Periodicals, Inc.
Hasegawa, Kohei; Hiraide, Atsushi; Chang, Yuchiao; Brown, David F M
2013-01-16
It is unclear whether advanced airway management such as endotracheal intubation or use of supraglottic airway devices in the prehospital setting improves outcomes following out-of-hospital cardiac arrest (OHCA) compared with conventional bag-valve-mask ventilation. To test the hypothesis that prehospital advanced airway management is associated with favorable outcome after adult OHCA. Prospective, nationwide, population-based study (All-Japan Utstein Registry) involving 649,654 consecutive adult patients in Japan who had an OHCA and in whom resuscitation was attempted by emergency responders with subsequent transport to medical institutions from January 2005 through December 2010. Favorable neurological outcome 1 month after an OHCA, defined as cerebral performance category 1 or 2. Of the eligible 649,359 patients with OHCA, 367,837 (57%) underwent bag-valve-mask ventilation and 281,522 (43%) advanced airway management, including 41,972 (6%) with endotracheal intubation and 239,550 (37%) with use of supraglottic airways. In the full cohort, the advanced airway group incurred a lower rate of favorable neurological outcome compared with the bag-valve-mask group (1.1% vs 2.9%; odds ratio [OR], 0.38; 95% CI, 0.36-0.39). In multivariable logistic regression, advanced airway management had an OR for favorable neurological outcome of 0.38 (95% CI, 0.37-0.40) after adjusting for age, sex, etiology of arrest, first documented rhythm, witnessed status, type of bystander cardiopulmonary resuscitation, use of public access automated external defibrillator, epinephrine administration, and time intervals. Similarly, the odds of neurologically favorable survival were significantly lower both for endotracheal intubation (adjusted OR, 0.41; 95% CI, 0.37-0.45) and for supraglottic airways (adjusted OR, 0.38; 95% CI, 0.36-0.40). In a propensity score-matched cohort (357,228 patients), the adjusted odds of neurologically favorable survival were significantly lower both for endotracheal intubation (adjusted OR, 0.45; 95% CI, 0.37-0.55) and for use of supraglottic airways (adjusted OR, 0.36; 95% CI, 0.33-0.39). Both endotracheal intubation and use of supraglottic airways were similarly associated with decreased odds of neurologically favorable survival. Among adult patients with OHCA, any type of advanced airway management was independently associated with decreased odds of neurologically favorable survival compared with conventional bag-valve-mask ventilation.
Nozzle insert for mixed mode fuel injector
Lawrence, Keith E [Peoria, IL
2006-11-21
A fuel injector includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set controlled respectively, by first and second needle valve members. The homogeneous charged nozzle outlet set is defined by a nozzle insert that is attached to an injector body, which defines the conventional nozzle outlet set. The nozzle insert is a one piece metallic component with a large diameter segment separated from a small diameter segment by an annular engagement surface. One of the needle valve members is guided on an outer surface of the nozzle insert, and the nozzle insert has an interference fit attachment to the injector body.
Application of several variable-valve-timing concepts to an LHR engine
NASA Technical Reports Server (NTRS)
Morel, T.; Keribar, R.; Sawlivala, M.; Hakim, N.
1987-01-01
The paper discusses advantages provided by electronically controlled hydraulically activated valves (ECVs) when applied to low heat rejection (LHR) engines. The ECV concept provides additional engine control flexibility by allowing for a variable valve timing as a function of speed and load, or for a given transient condition. The results of a study carried out to assess the benefits that this flexibility can offer to an LHR engine indicated that, when judged on the benefits to BSFC, volumetric efficiency, and peak firing pressure, ECVs would provide only modest benefits in comparison to conventional valve profiles. It is noted, however, that once installed on the engine, the ECVs would permit a whole range of certain more sophisticated variable valve timing strategies not otherwise possible, such as high compression cranking, engine braking, cylinder cutouts, and volumetric efficiency timing with engine speed.
NASA Technical Reports Server (NTRS)
Schey, Oscar W; Wilson, Ernest E
1929-01-01
This report presents the results of an analytical investigation on the practicability of using mechanically operated discharge valves in conjunction with a manually operated intake control for improving the performance of N. A. C. A. Roots type superchargers. These valves, which may be either of the oscillating or rotating type, are placed in the discharge opening of the supercharger and are so shaped and synchronized with the supercharger impellers that they do not open until the air has been compressed to the delivery pressure. The intake control limits the quantity of air compressed to engine requirements by permitting the excess air to escape from the compression chamber before compression begins. The percentage power saving and the actual horsepower saved were computed for altitudes from 0 to 20,000 feet. These computations are based on the pressure-volume cards for the conventional and the modified roots type superchargers and on the results of laboratory tests of the conventional type. The use of discharge valves shows a power saving of approximately 26 per cent at a critical altitude of 20,000 feet. In addition, these valves reduce the amplitude of the discharge pulsations and increase the volumetric efficiency. With slow-speed roots blowers operating at high-pressure differences even better results would be expected. For aircraft engine superchargers operating at high speeds these discharge valves increase the performance as above, but have the disadvantages of increasing the weight and of adding a high-speed mechanism to a simple machine. (author)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weller, C.L.; Rodda, E.D.; Steinberg, M.P.
Crude amylase preparations were produced by growing Aspergillus awamori and A. niger on raw ground whole corn. These Koji preparations were used to hydrolyze the starch of raw ground whole corn to sugars during simultaneous fermentation of the sugars to ethanol by distillers active dry yeast. Ethanol concentrations of the fermentation beers were determined with gas-chromatography. These fermentations yielded an average of 89.6% theoretical ethanol compared to control, conventional, fermentations that had an average of 89.8%. Carbon dioxide evolutions were determined with use of Alwood valves. Both the Koji and conventional fermentations produced an average of 0.48 gram of carbonmore » dioxide per gram of dry substrate starch within 72 hours. However, initially the conventional fermentation rate was greater. Koji dehydrated at 41 degrees C had no apparent detrimental effects on theoretical ethanol yield.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weller, C.L.; Rodda, E.D.; Steinberg, M.P.
Crude amylase preparations were produced by growing Aspergillus awamori and A. niger on raw ground whole corn. These Koji preparations were used to hydrolyze the starch of raw ground whole corn to sugars during simultaneous fermentation of the sugars to ethanol by distillers active dry yeast. Ethanol concentrations of the fermentation beers were determined with gas-chromatography. These fermentations yielded an average of 89.6% theoretical ethanol compared to control, conventional, fermentations that had an average of 89.8%. Carbon dioxide evolutions were determined with use of Alwood valves. Both the Koji and conventional fermentations produced an average of 0.48 gram of carbonmore » dioxide per gram of dry substrate starch within 72 hours. However, initially the conventional fermentation rate was greater. Koji dehydrated at 41/sup 0/C had no apparent detrimental effects on theoretical ethanol yield.« less
Tamcelik, Nevbahar; Ozkok, Ahmet; Sarıcı, Ahmet Murat; Atalay, Eray; Yetik, Huseyin; Gungor, Kivanc
2013-07-01
To present and compare the long-term results of Dr. Tamcelik's previously described technique of Tenon advancement and duplication with the conventional Ahmed glaucoma valve (AGV) implantation technique in patients with refractory glaucoma. This study was a multicenter, retrospective case series that included 303 eyes of 276 patients with refractory glaucoma who underwent glaucoma valve implantation surgery. The patients were divided into three groups according to the surgical technique applied and the outcomes compared. In group 1, 96 eyes of 86 patients underwent AGV implant surgery without patch graft; in group 2, 78 eyes of 72 patients underwent AGV implant surgery with donor scleral patch; in group 3, 129 eyes of 118 patients underwent Ahmed valve implant surgery with "combined short scleral tunnel with Tenon advancement and duplication technique". The endpoint assessed was tube exposure through the conjunctiva. In group 1, conjunctival tube exposure was seen in 11 eyes (12.9 %) after a mean 9.2 ± 3.7 years of follow-up. In group 2, conjunctival tube exposure was seen in six eyes (2.2 %) after a mean 8.9 ± 3.3 years of follow-up. In group 3, there was no conjunctival exposure after a mean 7.8 ± 2.8 years of follow-up. The difference between the groups was statistically significant. (P = 0.0001, Chi-square test). This novel surgical technique combining a short scleral tunnel with Tenon advancement and duplication was found to be effective and safe to prevent conjunctival tube exposure after AGV implantation surgery in patients with refractory glaucoma.
The Mars Development of a Micro-Isolation Valve
NASA Technical Reports Server (NTRS)
Mueller, Juergen; Vargo, Steven; Forgrave, John; Bame, David; Chakraborty, Indrani; Tang, William
1999-01-01
A feasibility investigation for a newly proposed microfabricated, normally-closed isolation valve was initiated. The micro-isolation valve is silicon based and relies on the principle of melting a silicon plug, opening an otherwise sealed flow passage. This valve may thus serve a similar role as a conventional pyrovalve and is intended for use in micropropulsion systems onboard future microspacecraft, having wet masses of no more than 10-20 kg, as well as in larger scale propulsion systems having only low flow rate requirements, such as ion propulsion or Hall thruster systems. Two key feasibility issues - melting of the plug and pressure handling capability - were addressed. Thermal finite element modeling showed that valves with plugs having widths between 10 and 50 gm have power requirements of only 10 . 30 Watts to open over a duration of 0.5 ms or less. Valve chips featuring 5 0 micron plugs were burst pressure tested and reached maximum pressure values o f 2900 psig (19.7 Mpa).
Investigation of a rotary valving system with variable valve timing for internal combustion engines
NASA Astrophysics Data System (ADS)
Cross, Paul C.; Hansen, Craig N.
1994-11-01
The objective of the program was to provide a functional demonstration of the Hansen Rotary Valving System with Variable Valve Timing (HRVS/VVT), capable of throttleless inlet charge control, as an alternative to conventional poppet-valves for use in spark ignited internal combustion engines. The goal of this new technology is to secure benefits in fuel economy, broadened torque band, vibration reduction, and overhaul accessibility. Additionally, use of the variable valve timing capability to vary the effective compression ratio is expected to improve multifuel tolerance and efficiency. Efforts directed at the design of HRVS components proved to be far more extensive than had been anticipated, ultimately requiring that proof-trial design/development work be performed. Although both time and funds were exhausted before optical or ion-probe types of in-cylinder investigation could be undertaken, a great deal of laboratory data was acquired during the course of the design/development work. This laboratory data is the basis for the information presented in this final report.
Magnon detection using a ferroic collinear multilayer spin valve.
Cramer, Joel; Fuhrmann, Felix; Ritzmann, Ulrike; Gall, Vanessa; Niizeki, Tomohiko; Ramos, Rafael; Qiu, Zhiyong; Hou, Dazhi; Kikkawa, Takashi; Sinova, Jairo; Nowak, Ulrich; Saitoh, Eiji; Kläui, Mathias
2018-03-14
Information transport and processing by pure magnonic spin currents in insulators is a promising alternative to conventional charge-current-driven spintronic devices. The absence of Joule heating and reduced spin wave damping in insulating ferromagnets have been suggested for implementing efficient logic devices. After the successful demonstration of a majority gate based on the superposition of spin waves, further components are required to perform complex logic operations. Here, we report on magnetization orientation-dependent spin current detection signals in collinear magnetic multilayers inspired by the functionality of a conventional spin valve. In Y 3 Fe 5 O 12 |CoO|Co, we find that the detection amplitude of spin currents emitted by ferromagnetic resonance spin pumping depends on the relative alignment of the Y 3 Fe 5 O 12 and Co magnetization. This yields a spin valve-like behavior with an amplitude change of 120% in our systems. We demonstrate the reliability of the effect and identify its origin by both temperature-dependent and power-dependent measurements.
NASA Technical Reports Server (NTRS)
Cole, G. L.; Dustin, M. O.; Neiner, G. H.
1975-01-01
Results of a wind tunnel investigation are presented. The inlet was modified so that airflow can be removed through a porous cowl-bleed region in the vicinity of the throat. Bleed plenum exit flow area is controlled by relief type mechanical valves. Unlike valves in previous systems, these are made for use in a high Mach flight environment and include refinements so that the system could be tested on a NASA YF-12 aircraft. The valves were designed to provide their own reference pressure. The results show that the system can absorb internal-airflow-transients that are too fast for a conventional bypass door control system and that the two systems complement each other quite well. Increased tolerance to angle of attack and Mach number changes is indicated. The valves should provide sufficient time for the inlet control system to make geometry changes required to keep the inlet started.
Off-design analysis of a gas turbine powerplant augmented by steam injection using various fuels
NASA Technical Reports Server (NTRS)
Stochl, R. J.
1980-01-01
Results are compared using coal derived low and intermediate heating valve fuel gases and a conventional distillate. The results indicate that steam injection provides substantial increases in both power and efficiency within the available compressor surge margin. The results also indicate that these performance gains are relatively insensitive as to the type of fuel. Also, in a cogeneration application, steam injection could provide some degree of flexibility by varying the split between power and process steam.
Dilip, D; Chandra, A; Rajashekhar, D; Padmanabhan, M
2001-05-01
Impairment of left ventricular (LV) function after mitral valve replacement (MVR) has been the most important factor to determine morbidity and mortality. With this in mind, LV performance in the postoperative period was assessed with and without preservation of papillo-annular continuity in MVR. Between March 1994 and August 1998, a total of 383 valve prostheses (202 MVR, 65 AVR, 58 MVR+AVR) were implanted in 325 patients, 177 of whom underwent MVR with Starr Edwards ball cage prostheses (the study group). Of these 177 patients, 105 had MVR with preservation of the posterior mitral leaflet (group I), and 72 had conventional MVR (group II). Predominant lesions were mitral stenosis in 81, mitral regurgitation in 42, and mixed mitral lesion (MS/MR) in 54. Concomitant tricuspid valve annuloplasty was performed in 13, and atrial septal defect repair in five. Sixteen patients underwent MVR for mitral restenosis. In-vivo performance of the prostheses and LV function was evaluated by M-mode and Doppler echocardiography. At 3-6 months clinical improvement was seen in NYHA class, with reduction in cardiothoracic ratio among patients with preserved papillo-annular continuity, irrespective of lesion type. Significant reductions (p <0.05) were seen in left atrial dimensions (54.10 +/- 8.79 preop. versus 44.64 +/- 8.54 postop.; p <0.05), left ventricular end-diastolic dimensions (LVEDD) (50.84 +/- 10.42 preop. versus 41.21 +/- 7.16 postop.; p <0.05) and end-systolic dimensions (LVESD) (34.76 +/- 7.94 preop. versus 28.81 +/- 5.79 postop.; p <0.05) in patients who had their posterior mitral leaflet preserved with significant improvement in ejection fraction (60.31 +/- 8.22 versus 64.47 +/- 7.93; p <0.05). Further analysis of data in group I patients showed significant reductions in left atrial dimensions, LVESD and peak gradient, along with improved ejection fraction compared with conventional (group II) patients. Deterioration in LV function in patients undergoing conventional MVR indicates chordal resection as a putative mechanism. This study supports the concept that maintenance of continuity between the mitral annulus and papillary muscles has a beneficial effect on postoperative LV function, and is particularly important in patients with mitral stenosis with depressed preoperative LV systolic function.
Sawa, Yoshiki; Takayama, Morimasa; Mitsudo, Kazuaki; Nanto, Shinsuke; Takanashi, Shuichiro; Komiya, Tatsuhiko; Kuratani, Toru; Tobaru, Tetsuya; Goto, Tsuyoshi
2015-01-01
Transcatheter aortic valve replacement (TAVR) is suggested to be less invasive and/or equally effective in comparison to conventional aortic valve replacement for high-risk symptomatic aortic stenosis patients. We herein report the initial results of a pivotal clinical trial of TAVR in Japan (the PREVAIL JAPAN). Sixty-four aortic stenosis patients (mean age 84.3 ± 6.1 years) not suitable for surgery were enrolled at three centers in Japan, with a primary composite endpoint of the 6-month post-procedure improvements in the aortic valve area and New York Heart Association (NYHA) functional classification. A transfemoral approach was used in 37 patients and a transapical approach was used in 27. The device success rate was 91.9 %. After 30 days and 6 months, the rates of mortality from any cause were 8.1 and 11.3 %, respectively. At 6 months, symptomatic stroke was found in 3.1 % of the patients, and silent infarction in 7.8 %. The aortic valve area and mean pressure gradient were significantly improved over time with both approaches (p < 0.001). At 6 months, the NYHA functional classification based on a conventional physician's assessment was improved in 87.9 % of the patients. We found results that were equivalent to those in other major TAVR trials, such as an acceptable 30-day survival (91.9 %), suggesting that balloon-expandable TAVR is effective for small Japanese AS patients classified as high-risk or inoperable.
NASA Astrophysics Data System (ADS)
Kadem, L.; Knapp, Y.; Pibarot, P.; Bertrand, E.; Garcia, D.; Durand, L. G.; Rieu, R.
2005-12-01
The effective orifice area (EOA) is the most commonly used parameter to assess the severity of aortic valve stenosis as well as the performance of valve substitutes. Particle image velocimetry (PIV) may be used for in vitro estimation of valve EOA. In the present study, we propose a new and simple method based on Howe’s developments of Lighthill’s aero-acoustic theory. This method is based on an acoustical source term (AST) to estimate the EOA from the transvalvular flow velocity measurements obtained by PIV. The EOAs measured by the AST method downstream of three sharp-edged orifices were in excellent agreement with the EOAs predicted from the potential flow theory used as the reference method in this study. Moreover, the AST method was more accurate than other conventional PIV methods based on streamlines, inflexion point or vorticity to predict the theoretical EOAs. The superiority of the AST method is likely due to the nonlinear form of the AST. There was also an excellent agreement between the EOAs measured by the AST method downstream of the three sharp-edged orifices as well as downstream of a bioprosthetic valve with those obtained by the conventional clinical method based on Doppler-echocardiographic measurements of transvalvular velocity. The results of this study suggest that this new simple PIV method provides an accurate estimation of the aortic valve flow EOA. This new method may thus be used as a reference method to estimate the EOA in experimental investigation of the performance of valve substitutes and to validate Doppler-echocardiographic measurements under various physiologic and pathologic flow conditions.
Subsurface safety valves: safety asset or safety liability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Busch, J.M.; Llewelyn, D.C.G.; Policky, B.J.
1983-10-01
This paper summarizes the methods used to compare the risk of a blowout for a well completed with a subsurface safety valve (SSSV) vs. a completion without an SSSV. These methods, which could be applied to any field, include a combination of SSSV reliability and conventional risk analyses. The Kuparuk River Unit Working Interest Owners recently formed a group to examine the risks associated with installing and maintaining SSSV's in the Kuparuk field. The group was charged with answering the question: ''Assuming Kuparuk field operating conditions, are SSSV's a safety asset, or do numerous operating and maintenance procedures make themmore » a safety liability.'' The results indicate that for the Kuparuk River Unit, an SSSV becomes a safety liability when the mean time between SSSV failures is less than one year. Since current SSSV mean time to failure (MTTF) at Kuparuk is approximately 1000 days, they are considered a safety asset.« less
Fast-responding liquid crystal light-valve technology for color-sequential display applications
NASA Astrophysics Data System (ADS)
Janssen, Peter J.; Konovalov, Victor A.; Muravski, Anatoli A.; Yakovenko, Sergei Y.
1996-04-01
A color sequential projection system has some distinct advantages over conventional systems which make it uniquely suitable for consumer TV as well as high performance professional applications such as computer monitors and electronic cinema. A fast responding light-valve is, clearly, essential for a good performing system. Response speed of transmissive LC lightvalves has been marginal thus far for good color rendition. Recently, Sevchenko Institute has made some very fast reflective LC cells which were evaluated at Philips Labs. These devices showed sub millisecond-large signal-response times, even at room temperature, and produced good color in a projector emulation testbed. In our presentation we describe our highly efficient color sequential projector and demonstrate its operation on video tape. Next we discuss light-valve requirements and reflective light-valve test results.
Modification and performance evaluation of a mono-valve engine
NASA Astrophysics Data System (ADS)
Behrens, Justin W.
A four-stroke engine utilizing one tappet valve for both the intake and exhaust gas exchange processes has been built and evaluated. The engine operates under its own power, but has a reduced power capacity than the conventional 2-valve engine. The reduction in power is traced to higher than expected amounts of exhaust gases flowing back into the intake system. Design changes to the cylinder head will fix the back flow problems, but the future capacity of mono-valve engine technology cannot be estimated. The back flow of exhaust gases increases the exhaust gas recirculation (EGR) rate and deteriorates combustion. Intake pressure data shows the mono-valve engine requires an advanced intake valve closing (IVC) time to prevent back flow of charge air. A single actuation camshaft with advanced IVC was tested in the mono-valve engine, and was found to improve exhaust scavenging at TDC and nearly eliminated all charge air back flow at IVC. The optimum IVC timing is shown to be approximately 30 crank angle degrees after BDC. The mono-valve cylinder head utilizes a rotary valve positioned above the tappet valve. The open spaces inside the rotary valveand between the rotary valve and tappet valve represent a common volume that needs to be reduced in order to reduce the base EGR rate. Multiple rotary valve configurations were tested, and the size of the common volume was found to have no effect on back flow but a direct effect on the EGR rate and engine performance. The position of the rotary valve with respect to crank angle has a direct effect on the scavenging process. Optimum scavenging occurs when the intake port is opened just after TDC.
Fault Study of Valve Based on Test Analysis and Comparison
NASA Astrophysics Data System (ADS)
Cheng, Li; Yang, Wukui; Liang, Tao; Xu, Yu; Chen, Chao
2017-10-01
The valve of a certain type of small engine often has the fault phenomenon of abnormal vibration noise and can’t close under the specified pressure, which may cause the engine automatic stop because of valve incomplete close leading to fuel leakage during test and startup on the bench. By test study compared to imported valve with the same use function and test condition valve, and put forward the thinking of improving valve structure, compared no-improved valve to improved valve by adopting Fluent field simulation software. As a result, improved valve can restore close pressure of valve, restrain abnormal vibration noise phenomenon, and effectively compensate compression value of spring because of steel ball contacting position downward with valve casing.
Fuel ethanol from raw corn by Aspergilli hydrolysis with concurrent yeast fermentation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weller, C.L.; Steinberg, M.P.; Rodda, E.D.
Crude amylase preparations were produced by growing Aspergillus awamori and A. niger on raw ground whole corn. These Koji preparations were used to hydrolyze the starch of raw ground whole corn to sugars during simultaneous fermentation of the sugars to ethanol by distillers active dry yeast. Ethanol concentrations of the fermentation beers were determined with gas chromatography. These fermentations yielded an average of 89.6% theoretical ethanol compared to control, conventional, fermentations that had an average of 89.9%. Carbon dioxide evolutions were determined with use of Alwood valves. Both the Koji and conventional fermentations produced an average of 0.48 g ofmore » carbon dioxide per gram of dry substrate starch within 72 h. However, initially the conventional fermentation rate was greater. Koji dehydrated at 41/sup 0/C had no apparent detrimental effects on theoretical ethanol yield. 41 references, 1 figure, 2 tables.« less
NASA Astrophysics Data System (ADS)
Sidhu, J. S.; Lathkar, G. S.; Sharma, S. B.
2018-01-01
The present attempt in this project is to reduce the vibrations, temperature due to friction, noise and weight of I C engine valve guide by replacing conventional metal valve guide with composite valve guide. Composite materials have been used in automotive components because of their properties such as low weight, high specific stiffness, corrosion resistance, ability to produce complex shapes, high specific strength and good impact energy absorption etc. The Internal combustion engine valve guides are the parts that support the valves in the cylinder head, besides this it keeps lubricating oil from getting sucked into the combustion chamber past the intake valve stem, it keeps exhaust gases from getting into the crankcase past the exhaust valve stem and it also keeps the valve face in perfect alignment with the valve seat. A valve guide test rig is indigenously fabricated. Valve guides are manufactured using the developed composite material (Resin ARL-136, Hardener AH-126 and 4 vol% WS2), on a CNC lathe. The performance of the developed composite guide under varied conditions of speeds, that is, fixed change in rpm and modulated changes in rpm is assessed. Noise, temperature and vibrations are measured. The experimental data revealed that contribution of composite guide in respect of acceleration, velocity and displacement components of vibration is not substantial. A substantial reduction in noise levels is seen. As far as temperature rise due to friction is concerned maximum components fail at elevated temperatures, with composite guides the temperature generated due to friction at higher speeds is less, a considerable weight reduction is also observed.
Cevasco, Marisa; Mick, Stephanie L; Kwon, Michael; Lee, Lawrence S; Chen, Edward P; Chen, Frederick Y
2013-05-01
Currently, there is no universal standard for sizing bioprosthetic aortic valves. Hence, a standardized comparison was performed to clarify this issue. Every size of four commercially available bioprosthetic aortic valves marketed in the United States (Biocor Supra; Mosaic Ultra; Magna Ease; Mitroflow) was obtained. Subsequently, custom sizers were created that were accurate to 0.0025 mm to represent aortic roots 18 mm through 32 mm, and these were used to measure the external diameter of each valve. Using the effective orifice area (EOA) and transvalvular pressure gradient (TPG) data submitted to the FDA, a comparison was made between the hemodynamic properties of valves with equivalent manufacturer stated sizes and valves with equivalent measured external diameters. Based on manufacturer size alone, the valves at first seemed to be hemodynamically different from each other, with Mitroflow valves appearing to be hemodynamically superior, having a large EOA and equivalent or superior TPG (p < 0.05). However, Mitroflow valves had a larger measured external diameter than the other valves of a given numerical manufacturer size. Valves with equivalent external diameters were then compared, regardless of the stated manufacturer sizes. For truly equivalently sized valves (i.e., by measured external diameter) there was no clear hemodynamic difference. There was no statistical difference in the EOAs between the Biocor Supra, Mosaic Ultra, and Mitroflow valves, and the Magna Ease valve had a statistically smaller EOA (p < 0.05). On comparing the mean TPG, the Biocor Supra and Mitroflow valves had statistically equivalent gradients to each other, as did the Mosaic Ultra and Magna Ease valves. When comparing valves of the same numerical manufacturer size, there appears to be a difference in hemodynamic performance across different manufacturers' valves according to FDA data. However, comparing equivalently measured valves eliminates the differences between valves produced by different manufacturers.
Ussia, Gian Paolo; Quadri, Arshad; Cammalleri, Valeria; De Vico, Pasquale; Muscoli, Saverio; Marchei, Massimo; Ruvolo, Giovanni; Sondergaard, Lars; Romeo, Francesco
2016-02-01
Transcatheter mitral valve implantation for mitral valve regurgitation is in the very early phase of development because of challenging anatomy and device dimensions. We describe the procedure of a transfemoral-transseptal implantation of the second-generation CardiAQ mitral valve bioprosthesis and 30-day follow-up. The procedure was performed percutaneously, without any left extracorporeal circulatory support. The patient had severe mitral regurgitation with severely depressed ventricular function and other comorbidities. The patient was deemed extreme high risk for conventional cardiac surgery by a multidisciplinary team. The main procedural steps were the creation of an arteriovenous loop with an exchange nitinol wire, and the use of a customised "steerable snare system" to facilitate the catheter delivery system into the mitral annulus. Transoesophageal echocardiography and fluoroscopy were utilised for device positioning and deployment. The mitral valve prosthesis was implanted with mild mitral regurgitation. The postoperative course was uneventful and at 30-day follow-up the patient is in NYHA Class I, with good function of the mitral valve bioprosthesis. This procedure shows that percutaneous transfemoral transcatheter mitral valve implantation is feasible, safe and successful. Further experience is needed to render this procedure clinically available.
Bernay, F; Bland, J M; Häggström, J; Baduel, L; Combes, B; Lopez, A; Kaltsatos, V
2010-01-01
Spironolactone, an aldosterone antagonist, has been demonstrated to decrease mortality in human patients when added to other cardiac therapies. Spironolactone in addition to conventional therapy increases survival compared with conventional therapy in dogs with naturally occurring myxomatous mitral valve disease (MMVD). Between February 2003 and March 2005, 221 dogs were recruited in Europe. Nine dogs were excluded from analysis, leaving 212 dogs with moderate to severe mitral regurgitation (MR) caused by MMVD (International Small Animal Cardiac Health Council classification classes II [n = 190] and III [n = 21]). Double-blinded, field study conducted with dogs randomized to receive either spironolactone (2 mg/kg once a day) or placebo in addition to conventional therapy (angiotensin converting enzyme inhibitor, plus furosemide and digoxin if needed). Primary endpoint was a composite of cardiac-related death, euthanasia, or severe worsening of MR. Primary endpoint reached by 11/102 dogs (10.8%) in the spironolactone group (6 deaths, 5 worsening) versus 28/110 (25.5%) in control group (14 deaths, 8 euthanasia, 6 worsening). Risk of reaching the composite endpoint significantly decreased by 55% (hazard ratio [HR] = 0.45; 95% confidence limits [CL], 0.22-0.90; log rank test, P = .017). Risk of cardiac-related death or euthanasia significantly reduced by 69% (HR = 0.31; 95% CL, 0.13-0.76; P = .0071). Number of dogs not completing the study for cardiac and other miscellaneous reasons similar in spironolactone (67/102) and control groups (66/110). Spironolactone added to conventional cardiac therapy decreases the risk of reaching the primary endpoint (ie, cardiac-related death, euthanasia, or severe worsening) in dogs with moderate to severe MR caused by MMVD.
Penna, Frank J; Bowlin, Paul; Alyami, Fahad; Bägli, Darius J; Koyle, Martin A; Lorenzo, Armando J
2015-10-01
In children with congenital obstructive uropathy, including posterior urethral valves, lower urinary tract decompression is recommended pending definitive surgical intervention. Current options, which are limited to a feeding tube or Foley catheter, pose unappreciated constraints in luminal diameter and are associated with potential problems. We assess the impact of luminal diameter on the current draining options and present a novel alternative method, repurposing a widely available stent that optimizes drainage. We retrospectively reviewed patients diagnosed with posterior urethral valves between January 2013 and December 2014. In all patients a 6Fr 12 cm Double-J ureteral stent was advanced over a guidewire in a retrograde fashion into the bladder. Luminal flow and cross-sectional areas were also assessed for each of 3 tubes for urinary drainage, ie 6Fr Double-J stent, 5Fr feeding tube and 6Fr Foley catheter. A total of 30 patients underwent uneventful bedside Double-J stent placement. Mean ± SD age at valve ablation was 28.5 ± 16.6 days. Mean ± SD peak serum creatinine was 2.23 ± 0.97 mg/dl after birth and 0.56 ± 0.22 mg/dl at the procedure. Urine output after stent placement was excellent in all patients. The Foley catheter and feeding tube drained approximately 18 and 6 times more slowly, respectively, and exhibited half the calculated cross-sectional luminal area compared to the Double-J stent. Use of Double-J stents in neonates with posterior urethral valves is a safe and effective alternative method for lower urinary tract decompression that optimizes the flow/lumen relationship compared to conventional drainage options. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Trans-catheter aortic valve implantation after previous aortic homograft surgery.
Drews, Thorsten; Pasic, Miralem; Buz, Semih; Unbehaun, Axel
2011-12-01
In patients with previous heart surgery, the operative risk is elevated during conventional aortic valve re-operations. Trans-catheter aortic valve implantation is a new method for the treatment of high-risk patients. Nevertheless, this new procedure carries potential risks in patients with previous homograft implantation in aortic position. Between April 2008 and February 2011, 345 consecutive patients (mean EuroSCORE (European System for Cardiac Operative Risk Evaluation): 38 ± 20%; mean Society of Thoracic Surgeons (STS) Mortality Score: 19 ± 16%; mean age: 80 ± 8 years; 111 men and 234 women) underwent trans-apical aortic valve implantation. In three patients, previous aortic homograft implantation had been performed. Homograft degeneration causing combined valve stenosis and incompetence made re-operation necessary. In all three patients, the aortic valve could be implanted using the trans-apical approach, and the procedure was successful. In two patients, there was slight paravalvular leakage of the aortic prosthesis and the other patient had slight central leakage. Neither ostium obstruction nor mitral valve damage was observed. Trans-catheter valve implantation can be performed successfully after previous homograft implantation. Particular care should be taken to achieve optimal valve positioning, not to obstruct the ostium of the coronary vessels due to the changed anatomic situation and not to cause annulus rupture. Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
The Value of Circulating Biomarkers in Bicuspid Aortic Valve-Associated Aortopathy.
Naito, Shiho; Hillebrand, Mathias; Bernhardt, Alexander Martin Justus; Jagodzinski, Annika; Conradi, Lenard; Detter, Christian; Sydow, Karsten; Reichenspurner, Hermann; Kodolitsch, Yskert von; Girdauskas, Evaldas
2018-06-01
Traditional risk stratification model of bicuspid aortic valve (BAV) aortopathy is based on measurement of maximal cross-sectional aortic diameter, definition of proximal aortic shape, and aortic stiffness/elasticity parameters. However, conventional imaging-based criteria are unable to provide reliable information regarding the risk stratification in BAV aortopathy, especially considering the heterogeneous nature of BAV disease. Given those limitations of conventional imaging, there is a growing clinical interest to use circulating biomarkers in the screening process for thoracic aortic aneurysms as well as in the risk-assessment algorithms. We aimed to systematically review currently available biomarkers, which may be of value to predict the natural evolution of aortopathy in individuals with BAV. Georg Thieme Verlag KG Stuttgart · New York.
Large Scale Magnetostrictive Valve Actuator
NASA Technical Reports Server (NTRS)
Richard, James A.; Holleman, Elizabeth; Eddleman, David
2008-01-01
Marshall Space Flight Center's Valves, Actuators and Ducts Design and Development Branch developed a large scale magnetostrictive valve actuator. The potential advantages of this technology are faster, more efficient valve actuators that consume less power and provide precise position control and deliver higher flow rates than conventional solenoid valves. Magnetostrictive materials change dimensions when a magnetic field is applied; this property is referred to as magnetostriction. Magnetostriction is caused by the alignment of the magnetic domains in the material s crystalline structure and the applied magnetic field lines. Typically, the material changes shape by elongating in the axial direction and constricting in the radial direction, resulting in no net change in volume. All hardware and testing is complete. This paper will discuss: the potential applications of the technology; overview of the as built actuator design; discuss problems that were uncovered during the development testing; review test data and evaluate weaknesses of the design; and discuss areas for improvement for future work. This actuator holds promises of a low power, high load, proportionally controlled actuator for valves requiring 440 to 1500 newtons load.
2007-11-01
or other pesticides, or as fumigants for rodent extermination. Additionally, they all are used as a raw material for the synthesis of other chemicals...pressure/ vacuum valve NMR sample tubes (Catalog number 528- PV-9), were purchased from Wilmad-Labglass (Buena, NJ). 2.2 Sample Preparation Hydrogen...cyanide, cyanogen chloride, and phosgene were prepared for NMR spectroscopy by condensing their respective gases into pressure/ vacuum valve NMR sample
Trans-apical aortic valve implantation in patients with severe calcification of the ascending aorta.
Buz, Semih; Pasic, Miralem; Unbehaun, Axel; Drews, Thorsten; Dreysse, Stephan; Kukucka, Marian; Mladenow, Alexander; Hetzer, Roland
2011-08-01
In patients with calcification of the ascending aorta, postoperative stroke and mortality rates remain high after conventional aortic valve replacement, but the results of trans-apical aortic valve implantation in these patients are not known. We evaluate the outcome of trans-apical aortic valve implantation in patients with severely calcified ascending aorta in a single center with expanded procedural experience. Between April 2008 and July 2010, 258 patients underwent trans-apical aortic valve implantation using Edwards Sapien valve. By computed tomography (CT) scan, we identified 46 (18%) patients with severe calcification of the ascending aorta (16 with porcelain aorta and 30 with severe, but not complete, calcification). Of 46 patients (mean age 77 ± 10 years, range 63-90 years; EuroSCORE (European System for Cardiac Operative Risk Evaluation) 45 ± 22%; STS (Society of Thoracic Surgeons) score 23 ± 13) with calcified aorta, 15 received 23-mm valves and 31 patients 26-mm valves. Primary valve implantation was successful in 44 patients and a second valve was implanted (valve-in-valve) in two. Six patients underwent concomitant interventions (three elective percutaneous coronary intervention (PCI), one off-pump coronary artery bypass (OPCAB), one tricuspid valve reconstruction, and one left-ventricular (LV) aneurysmectomy). The final procedural results showed valve incompetence (trace or grade 1) in 17 (37%) patients and paravalvular leak in 15 (32.6%) (trace in 10 and grade 1 in five). There was no 30-day mortality. Postoperatively, cranial CT showed new cerebral ischemia areas in three patients (6.2%), but only one patient (2.1%) experienced postoperative neurological deficit (temporary aphasia). Survival at 6 and 12 months was 88% and 85.2%, respectively. Trans-apical aortic valve implantation can be performed safely in patients with aortic valve stenosis and severe calcification of the ascending aorta. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Rho, Seungsoo; Sung, Youngje; Ma, Kyoung Tak; Rho, Sae Heun; Kim, Chan Yun
2015-09-01
To evaluate the short-term efficacy of a biodegradable collagen matrix (BCM) as an adjuvant for Ahmed valve implantation surgery to prevent the hypertensive phase. This prospective study included 43 refractory glaucoma eyes, all followed for 6 months. Refractory glaucoma was defined as an IOP higher than 20 mm Hg with antiglaucoma eye drops without previous glaucoma surgery. Conventional method was performed in 21 eyes and BCM-augmented Ahmed valve implantation (BAAVI) in 22 eyes. In the BAAVI group, a 10 × 10 × 2-mm BCM was sutured on an Ahmed glaucoma valve FP7 model. Complete success was defined as an IOP of 21 mm Hg or lower (target IOP 1) or 17 mm Hg or lower (target IOP 2) without antiglaucoma medications and qualified success as an IOP of 21 mm Hg or lower with or without medications. Maximal bleb thickness was measured using anterior segment optical coherence tomography images. The preoperative IOPs and numbers of preoperative antiglaucoma medications were similar for both groups. Complete target IOP 1 success rates were 38.1% and 86.4%, complete target IOP 2 success rates were 19.0% and 59.1%, and qualified success rates were 52.4% and 90.9% in the conventional and BAAVI groups, respectively (P < 0.05). The hypertensive phase rate was lower in the BAAVI group (4.5% vs. 47.6%, P = 0.002). Maximal bleb thickness was increased in the BAAVI group on postoperative days 30 and 180 (P < 0.05). Success rates were higher in the BAAVI group than in the conventional group with the change of bleb morphology. Furthermore, use of BCM significantly decreased the need for antiglaucoma medications for at least 6 months postoperatively.
Vent-induced prosthetic leaflet thrombosis treated by open-heart valve-in-valve implantation.
Stamm, Christof; Pasic, Miralem; Buz, Semih; Hetzer, Roland
2015-09-01
A patient required emergency mitral valve replacement and extracorporeal membrane oxygenation (ECMO) support for acute biventricular failure. The left ventricular (LV) vent inserted via the left upper pulmonary vein induced thrombotic immobilization of a prosthetic valve leaflet, with significant intra-prosthesis regurgitation after ECMO explantation. Therefore, the left atrium was opened on the beating heart during conventional extracorporeal circulation, all prosthesis leaflets were excised and a 29-mm expandable Edwards Sapien prosthesis was inserted within the scaffold of the original prosthesis under direct vision. This case illustrates the benefits and potential problems of LV venting on ECMO support, and a rapid and safe way of replacing the prosthesis leaflets in a critical situation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Aortic annulus sizing using watershed transform and morphological approach for CT images
NASA Astrophysics Data System (ADS)
Mohammad, Norhasmira; Omar, Zaid; Sahrim, Mus'ab
2018-02-01
Aortic valve disease occurs due to calcification deposits on the area of leaflets within the human heart. It is progressive over time where it can affect the mechanism of the heart valve. To avoid the risk of surgery for vulnerable patients especially senior citizens, a new method has been introduced: Transcatheter Aortic Valve Implantation (TAVI), which places a synthetic catheter within the patient's valve. This entails a procedure of aortic annulus sizing, which requires manual measurement of the scanned images acquired from Computed Tomographic (CT) by experts. The step requires intensive efforts, though human error may still eventually lead to false measurement. In this research, image processing techniques are implemented onto cardiac CT images to achieve an automated and accurate measurement of the heart annulus. The image is first put through pre-processing for noise filtration and image enhancement. Then, a marker image is computed using the combination of opening and closing operations where the foreground image is marked as a feature while the background image is set to zero. Marker image is used to control the watershed transformation and also to prevent oversegmentation. This transformation has the advantage of fast computational and oversegmentation problems, which usually appear with the watershed transform can be solved with the introduction of marker image. Finally, the measurement of aortic annulus from the image data is obtained through morphological operations. Results affirm the approach's ability to achieve accurate annulus measurements compared to conventional techniques.
Thomas, W P; Gaber, C E; Jacobs, G J; Kaplan, P M; Lombard, C W; Moise, N S; Moses, B L
1993-01-01
Recommendations are presented for standardized imaging planes and display conventions for two-dimensional echocardiography in the dog and cat. Three transducer locations ("windows") provide access to consistent imaging planes: the right parasternal location, the left caudal (apical) parasternal location, and the left cranial parasternal location. Recommendations for image display orientations are very similar to those for comparable human cardiac images, with the heart base or cranial aspect of the heart displayed to the examiner's right on the video display. From the right parasternal location, standard views include a long-axis four-chamber view and a long-axis left ventricular outflow view, and short-axis views at the levels of the left ventricular apex, papillary muscles, chordae tendineae, mitral valve, aortic valve, and pulmonary arteries. From the left caudal (apical) location, standard views include long-axis two-chamber and four-chamber views. From the left cranial parasternal location, standard views include a long-axis view of the left ventricular outflow tract and ascending aorta (with variations to image the right atrium and tricuspid valve, and the pulmonary valve and pulmonary artery), and a short-axis view of the aortic root encircled by the right heart. These images are presented by means of idealized line drawings. Adoption of these standards should facilitate consistent performance, recording, teaching, and communicating results of studies obtained by two-dimensional echocardiography.
Taramasso, Maurizio; Inderbitzin, Devdas T; Guidotti, Andrea; Nietlispach, Fabian; Gaemperli, Oliver; Zuber, Michel; Maisano, Francesco
2016-01-01
Direct mitral valve annuloplasty is a transcatheter mitral valve repair approach that mimics the conventional surgical approach to treat functional mitral regurgitation. The Cardioband system (Valtech Cardio, Inc., Or-Yehuda, Israel) is delivered by a trans-septal approach and the implant is performed on the atrial side of the mitral annulus, under live echo and fluoroscopic guidance using multiple anchor elements. The Cardioband system obtained CE mark approval in October 2015, and initial clinical experiences are promising with regard to feasibility, safety and efficacy. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Fuel injection of coal slurry using vortex nozzles and valves
Holmes, Allen B.
1989-01-01
Injection of atomized coal slurry fuel into an engine combustion chamber is achieved at relatively low pressures by means of a vortex swirl nozzle. The outlet opening of the vortex nozzle is considerably larger than conventional nozzle outlets, thereby eliminating major sources of failure due to clogging by contaminants in the fuel. Control fluid, such as air, may be used to impart vorticity to the slurry and/or purge the nozzle of contaminants during the times between measured slurry charges. The measured slurry charges may be produced by a diaphragm pump or by vortex valves controlled by a separate control fluid. Fluidic circuitry, employing vortex valves to alternatively block and pass cool slurry fuel flow, is disclosed.
Sharma, Ashutosh; Cote, Anita T; Hosking, Martin C K; Harris, Kevin C
2017-07-24
The aim of this study was to systematically evaluate the incidence of infective endocarditis (IE) in right ventricle-to-pulmonary artery conduits and valves, comparing bovine jugular vein (BJV) valves with all others. Recent evidence suggests that the incidence of IE is higher in patients with congenital heart disease who have undergone implantation of BJV valves in the pulmonary position compared with other valves. Systematic searches of published research were conducted using electronic databases (MEDLINE, Embase, and CINAHL) and citations cross-referenced current to April 2016. Included studies met the following criteria: patients had undergone right ventricle-to-pulmonary artery conduit or percutaneous pulmonary valve implantation, and investigators reported on the type of conduit or valve implanted, method of intervention (surgery or catheter based), IE incidence, and follow-up time. Fifty studies (Levels of Evidence: 2 to 4) were identified involving 7,063 patients. The median cumulative incidence of IE was higher for BJV compared with other valves (5.4% vs. 1.2%; p < 0.0001) during a median follow-up period of 24.0 and 35.5 months, respectively (p = 0.03). For patients with BJV valves, the incidence of IE was not different between surgical and catheter-based valve implantation (p = 0.83). There was a higher incidence of endocarditis with BJV valves than other types of right ventricle-to-pulmonary artery conduits. There was no difference in the incidence of endocarditis between catheter-based bovine valves and surgically implanted bovine valves, suggesting that the substrate for future infection is related to the tissue rather than the method of implantation. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Microfluidic droplet sorting using integrated bilayer micro-valves
NASA Astrophysics Data System (ADS)
Chen, Yuncong; Tian, Yang; Xu, Zhen; Wang, Xinran; Yu, Sicong; Dong, Liang
2016-10-01
This paper reports on a microfluidic device capable of sorting microfluidic droplets utilizing conventional bilayer pneumatic micro-valves as sorting controllers. The device consists of two micro-valves placed symmetrically on two sides of a sorting area, each on top of a branching channel at an inclined angle with respect to the main channel. Changes in transmitted light intensity, induced by varying light absorbance by each droplet, are used to divert the droplet from the sorting area into one of the three outlet channels. When no valve is activated, the droplet flows into the outlet channel in the direction of the main channel. When one of the valves is triggered, the flexible membrane of valve will first be deflected. Once the droplet leaves the detection point, the deflected membrane will immediately return to its default flattened position, thereby exerting a drawing pressure on the droplet and deviating it from its original streamline to the outlet on the same side as the valve. This sorting method will be particularly suitable for numerous large-scale integrated microfluidic systems, where pneumatic micro-valves are already used. Only few structural modifications are needed to achieve droplet sorting capabilities in these systems. Due to the mechanical nature of diverting energy applied to droplets, the proposed sorting method may induce only minimal interference to biological species or microorganisms encapsulated inside the droplets that may accompany electrical, optical and magnetic-based techniques.
García-Bengochea, José; Sierra, Juan; González-Juanatey, José R; Rubio, José; Vega, Marino; Fernández, Angel L; Sánchez, Daniel
2006-05-01
The study aim was to evaluate the durability of the new Mitroflow 12A pericardial bioprosthesis and to assess ventricular mass regression after aortic valve replacement (AVR) in patients with small valves. A total of 326 Mitroflow 12A pericardial bioprostheses was implanted without any other associated valve procedure. The mean patient age was 73.5 +/- 6.1 years; 252 patients (78.0%) were in NYHA class III/IV. Small valves (19 and 21 mm) were implanted in 212 patients (65.6%). The total follow up period was 837.1 patient-years (pt-yr). A subset of 61 patients with preoperative stenosis was selected and submitted to conventional echo-Doppler assessment at a mean period of 11.1 months after surgery. Hospital mortality was 8.6%. At eight years of follow up, survival was 57.1%. Freedom from structural valve deterioration (SVD) was 86.5% per pt-yr. Mean gradients were significantly reduced postoperatively for each valve size (to 18 +/- 8 mmHg for 19-mm valves and 12 +/- 4 mmHg for 25-mm valves). The effective orifice area (EOA) was also increased significantly for all valve sizes (to 1.1 +/- 0.1 cm2 for 19-mm valves and 1.8 +/- 0.2 cm2 for 25-mm valves). The left ventricular mass index (LVMI) decreased significantly, from 177 +/- 29 to 136 +/- 22 g/m2 for the 19-mm valve, and from 200 +/- 42 to 132 +/- 22 g/m2 for the 25-mm valve. The EOA index (EOAI) showed mismatch for the 19- and 21-mm valves (0.74 and 0.82 cm2/m2, respectively). The diagrammatic calculation between LVMI and relative wall thickness after surgery showed that 29.7% of patients achieved a normal pattern of remodeling (including 19- and 21-mm valves), despite various degrees of mismatch. The new Mitroflow 12A pericardial bioprosthesis showed an absence of mechanical failure after an eight-year follow up, with a satisfactory rate of SVD. Significant reductions in LVMI and improved ventricular geometry were observed, despite the small valve sizes implanted.
Late complications in patients with Björk-Shiley and St. Jude Medical heart valve replacement.
Horstkotte, D; Körfer, R; Seipel, L; Bircks, W; Loogen, F
1983-09-01
Valve-related complications after Björk-Shiley mitral valve implantation (n = 475), aortic valve implantation (n = 424), or mitral-aortic valve implantation (n = 119) were compared with those after St. Jude Medical mitral valve replacement (n = 173), aortic valve replacement (n = 152), or mitral-aortic valve replacement (n = 69). All patients were placed on anticoagulant therapy with phenprocoumon early after operation. All patients had a comparable follow-up time of approximately 23 months, which showed that cumulative thromboembolic rates were significantly higher after St. Jude valve implantation than after Björk-Shiley valve implantation. Reoperations were necessary because of valve thrombosis (0.46%), perivalvular leakage (2.2%), or prosthetic valve endocarditis with perivalvular regurgitation (0.46%). One Björk-Shiley mitral valve prosthesis had to be replaced because of fracture of the outlet strut. Without significant intergroup differences, hemorrhage due to anticoagulant treatment was the most frequent complication. Thromboembolic complications were significantly more frequent after Björk-Shiley mitral, aortic, and double valve replacements than after St. Jude valve implantation. This may lead to consideration of changes in the prophylaxis of thrombus formations in the St. Jude valve, especially in aortic valve replacements, in patients with sinus rhythm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soleimanikahnoj, S.; Knezevic, I.
Zigzag phosphorene nanoribbons are metallic owing to the edge states, whose energies are inside the gap and far from the bulk bands. We show that -- through electrical manipulation of edge states -- electron propagation can be restricted to one of the ribbon edges or, in case of bilayer phosphorene nanoribbons, to one of the layers. This finding implies that edge and layer can be regarded as tunable equivalents of the spin-one-half degree of freedom, i.e., the pseudospin. In both layer- and edge-pseudospin schemes, we propose and characterize a pseudospin field-effect transistor, which can generate pseudospin-polarized current. Also, we proposemore » edge- and layer-pseudospin valves that operate analogously to conventional spin valves. The performance of valves in each pseudospin scheme is benchmarked by the pseudomagnetoresistance (PMR) ratio. The edge-pseudospin valve shows a nearly perfect PMR, with remarkable robustness against device parameters and disorder. Furthermore, these results may initiate new developments in pseudospin electronics.« less
[TAVI in 2018 : new indications and open questions].
Fournier, Stephane; Roguelov, Christan; Monney, Pierre; Kirsch, Mathias; Eeckhout, Eric; Antiochos, Panagiotis; Lamsidri, Sabine; Muller, Olivier
2018-05-23
The last years, various large randomized studies have demonstrated the benefit of TAVI (transcatheter aortic valve implantation) over medical therapy or over conventional surgical treatment in inoperable or very high risk patients with symptomatic severe aortic stenosis. More recently, new data has also shown that among patients at intermediate risk, TAVI is at least as beneficial as surgical valve replacement. In this article, we will focus on the new recommendations of the European society of cardiology but also on issues that remain open.
Endothelial Progenitor Cells as a Sole Source for Ex Vivo Seeding of Tissue-Engineered Heart Valves
Mettler, Bret A.; Engelmayr, George C.; Aikawa, Elena; Bischoff, Joyce; Martin, David P.; Exarhopoulos, Alexis; Moses, Marsha A.; Schoen, Frederick J.; Sacks, Michael S.
2010-01-01
Purposes: We investigated whether circulating endothelial progenitor cells (EPCs) can be used as a cell source for the creation of a tissue-engineered heart valve (TEHV). Methods: Trileaflet valved conduits were fabricated using nonwoven polyglycolic acid/poly-4-hydroxybutyrate polymer. Ovine peripheral blood EPCs were dynamically seeded onto a valved conduit and incubated for 7, 14, and 21 days. Results: Before seeding, EPCs were shown to express CD31+, eNOS+, and VE-Cadherin+ but not α-smooth muscle actin. Histological analysis demonstrated relatively homogenous cellular ingrowth throughout the valved conduit. TEHV constructs revealed the presence of endothelial cell (EC) markers and α-smooth muscle actin+ cells comparable with native valves. Protein levels were comparable with native valves and exceeded those in unseeded controls. EPC-TEHV demonstrated a temporal pattern of matrix metalloproteinases-2/9 expression and tissue inhibitors of metalloproteinase activities comparable to that of native valves. Mechanical properties of EPC-TEHV demonstrated significantly greater stiffness than that of the unseeded scaffolds and native valves. Conclusions: Circulating EPC appears to have the potential to provide both interstitial and endothelial functions and could potentially serve as a single-cell source for construction of autologous heart valves. PMID:19698056
Itagaki, Shinobu; Chikwe, Joanna P; Chiang, Yuting P; Egorova, Natalia N; Adams, David H
2015-06-09
Bicuspid aortic valves are associated with valve dysfunction, ascending aortic aneurysm and dissection. Management of the ascending aorta at the time of aortic valve replacement (AVR) in these patients is controversial and has been extrapolated from experience with Marfan syndrome, despite the absence of comparative long-term outcome data. This study sought to assess whether the natural history of thoracic aortopathy after AVR in patients with bicuspid aortic valve disease is substantially different from that seen in patients with Marfan syndrome. In this retrospective comparison, outcomes of 13,205 adults (2,079 with bicuspid aortic valves, 73 with Marfan syndrome, and 11,053 control patients with acquired aortic valve disease) who underwent primary AVR without replacement of the ascending aorta in New York State between 1995 and 2010 were compared. The median follow-up time was 6.6 years. The long-term incidence of thoracic aortic dissection was significantly higher in patients with Marfan syndrome (5.5 ± 2.7%) compared with those with bicuspid valves (0.55 ± 0.21%) and control group patients (0.41 ± 0.08%, p < 0.001). Thoracic aortic aneurysms were significantly more likely to be diagnosed in late follow-up in patients with Marfan syndrome (10.8 ± 4.4%) compared with those with bicuspid valves (4.8 ± 0.8%) and control group patients (1.4 ± 0.2%) (p < 0.001). Patients with Marfan syndrome were significantly more likely to undergo thoracic aortic surgery in late follow-up (10.4 ± 4.3%) compared with those with bicuspid valves (2.5 ± 0.6%) and control group patients (0.50 ± 0.09%) (p < 0.001). The much higher long-term rates of aortic complications after AVR observed in patients with Marfan syndrome compared with those with bicuspid aortic valves confirm that operative management of patients with bicuspid aortic valves should not be extrapolated from Marfan syndrome and support discrete treatment algorithms for these different clinical entities. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Gil-Carrasco, F; Jiménez-Román, J; Turati-Acosta, M; Bello-López Portillo, H; Isida-Llerandi, C G
2016-09-01
To prospectively evaluate the safety and efficacy of the Ahmed glaucoma valve model M4 (High density porous polyethylene plate; Medpor) compared with the model S2 (polypropylene plate). Mexican patients with neovascular glaucoma were randomly included for each group (M4 and S2). They were operated on using conventional techniques and creating a sub-episcleral tunnel to place the valve tube in the anterior chamber. After one year of follow-up, the results were evaluated with respect to a post-operative reduction in pressure, changes in visual acuity, the need for drugs, and complications, as well as the demographic characteristics of each group. Each operation using the M4 valve was performed by a single surgeon (FGC). Those operated on using the S2 model had their surgery performed by the staff surgeons at the Glaucoma Department of the Mexican Association to Prevent Blindness (APEC). Each group (M4 and S2) contained 21 eyes of 21 Mexican patients with a diagnosis of neovascular glaucoma, leading to a total of 42 patients undergoing surgery. The mean preoperative intraocular pressure (IOP) was 43.5 (±11.8), and 42.24 (±12.84) mmHg for the M4 and S2 groups, respectively. After one year of follow-up, the IOP reported was 18.9 (±9.7) mmHg for the final 18 patients in the M4 group, and 16.38 (±9.76) mmHg for the 21 patients in the S2 group. The design of a drainage valve device such as that of Ahmed has characteristics such as moderate control of IOP, thanks to the valve component in the immediate post-operative period, which makes them safer than other non-valve devices. This avoids an excess of flat chambers and the presence of low IOPs, which can lead to bleeding in the early post-operative period due to the weak desmosomal junctions of the newly formed vessels, with the advantage of maintaining suitable control of IOP from the first day after surgery. Further studies with longer follow-up with a larger number of patients are needed to evaluate the effectiveness of this porous coating in the control of neovascular glaucoma. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.
Improvement of a Pneumatic Control Valve with Self-Holding Function
NASA Astrophysics Data System (ADS)
Dohta, Shujiro; Akagi, Tetsuya; Kobayashi, Wataru; Shimooka, So; Masago, Yusuke
2017-10-01
The purpose of this study is to develop a small-sized, lightweight and low-cost control valve with low energy consumption and to apply it to the assistive system. We have developed some control valves; a tiny on/off valve using a vibration motor, and an on/off valve with self-holding function. We have also proposed and tested the digital servo valve with self-holding function using permanent magnets and a small-sized servo motor. In this paper, in order to improve the valve, an analytical model of the digital servo valve is proposed. And the simulated results by using the analytical model and identified parameters were compared with the experimental results. Then, the improved digital servo valve was designed based on the calculated results and tested. As a result, we realized the digital servo valve that can control the flow rate more precisely while maintaining its volume and weight compared with the previous valve. As an application of the improved valve, a position control system of rubber artificial muscle was built and the position control was performed successfully.
Continent cecostomy. An account of 30 patients.
Kock, N G; Myrvold, H E; Philipson, B M; Svaninger, G; Ojerskog, B
1985-10-01
In this paper, an account is given of our experience with continent colostomy in man. In five patients, the end-sigmoidostomy was provided with an intussusception valve. Evacuation of the bowel by irrigation through a catheter was laborious and time-consuming and this method was abandoned. In another group of 30 patients, the cecum was isolated from the rest of the colon and its distal end was provided with an intussusception valve. Of the 30 patients, eight were later given continent ileostomies, two were converted to conventional sigmoidostomies, and one patient with fecal incontinence preferred to have intestinal continuity reestablished. Thus, 19 patients still have continent cecostomies and are satisfied with their function. When comparing the function of the continent cecostomy with that of the continent ileostomy, however, it is obvious that the ileostomy function is superior. The experience obtained with this group of patients has resulted in a widening of the indications for constructing a continent ileostomy, including selected patients with various anorectal disorders.
The double switch for atrioventricular discordance.
Brawn, William J
2005-01-01
Conventional surgery for atrioventricular discordance usually associated with ventricular arterial discordance leaves the morphologic right ventricle in the systemic circulation. Long-term follow-up results with this approach reveal a high incidence of right ventricular failure. The double switch procedure was introduced to restore the morphologic left ventricle to the systemic circulation. This operation is performed in two main ways: the atrial-arterial switch and the atrial switch plus Rastelli procedure. This double switch approach has been successful at least in the medium term in abolishing morphologic right ventricular failure and its associated tricuspid valve regurgitation. In the atrial-arterial switch group, there is an incidence of morphologic left ventricular dysfunction, sometimes associated with neoaortic valve regurgitation, and the minority of cases need aortic valve replacement. The long-term function of the morphologic left ventricle and the aortic valve need careful surveillance in the future. The atrial-Rastelli group of patients has not in the medium term shown evidence of ventricular dysfunction but will require change on a regular basis of their ventricular to pulmonary artery valved conduits.
[Results of fistulizing and Ahmed valve surgery for treatment of refractory glaucoma].
Bikbov, M M; Babushkin, A E; Chaĭka, O V; Orenburkina, O I; Matiukhina, E N
2014-01-01
Surgical results of 76 patients (76 eyes) aged 25-79 years with secondary refractory glaucoma were analyzed. The best hypotensive effect and visual functions integrity were achieved with Ahmed valve implantation (86.7% and 83.3% of cases respectively); after conventional fistulizing surgery the hypotensive effect was observed in 45.5%, noncompromised vision--in 54.5% of cases. Tunnel trabeculectomy with iridocycloretraction led to normalization of intraocular pressure and stabilization of visual functions in 81.3% and 68.8% of cases respectively and thus can be considered as an alternative to fistulizing surgery in patients with secondary refractory glaucoma. Uveal glaucoma is a relative contraindication to Ahmed valve implantation, while neovascular glaucoma is that to tunnel trabeculectomy with iridocycloretraction.
The role of TTE in assessment of the patient before and following TAVI for AS
Edwards, Nicola C; Doshi, Sagar N; Steeds, Richard P
2016-01-01
Transcatheter aortic valve implantation is now accepted as a standard mode of treatment for an increasingly large population of patients with severe aortic stenosis. With the availability of this technique, echocardiographers need to be familiar with the imaging characteristics that can help to identify which patients are best suited to conventional surgery or transcatheter aortic valve implantation, and what parameters need to be measured. This review highlights the major features that should be assessed during transthoracic echocardiography before presentation of the patient to the ‘Heart Team’. In addition, this review summarises the aspects to be considered on echocardiography during follow-up assessment after successful implantation of a transcatheter aortic valve. PMID:27249549
Exhaust gas bypass valve control for thermoelectric generator
Reynolds, Michael G; Yang, Jihui; Meisner, Greogry P.; Stabler, Francis R.; De Bock, Hendrik Pieter Jacobus; Anderson, Todd Alan
2012-09-04
A method of controlling engine exhaust flow through at least one of an exhaust bypass and a thermoelectric device via a bypass valve is provided. The method includes: determining a mass flow of exhaust exiting an engine; determining a desired exhaust pressure based on the mass flow of exhaust; comparing the desired exhaust pressure to a determined exhaust pressure; and determining a bypass valve control value based on the comparing, wherein the bypass valve control value is used to control the bypass valve.
In Vitro Hydrodynamic Assessment of a New Transcatheter Heart Valve Concept (the TRISKELE).
Rahmani, Benyamin; Tzamtzis, Spyros; Sheridan, Rose; Mullen, Michael J; Yap, John; Seifalian, Alexander M; Burriesci, Gaetano
2017-04-01
This study presents the in vitro hydrodynamic assessment of the TRISKELE, a new system suitable for transcatheter aortic valve implantation (TAVI), aiming to mitigate the procedural challenges experienced with current technologies. The TRISKELE valve comprises three polymeric leaflet and an adaptive sealing cuff, supported by a novel fully retrievable self-expanding nitinol wire frame. Valve prototypes were manufactured in three sizes of 23, 26, and 29 mm by automated dip-coating of a biostable polymer, and tested in a hydrodynamic bench setup in mock aortic roots of 21, 23, 25, and 27 mm annulus, and compared to two reference valves suitable for equivalent implantation ranges: Edwards SAPIEN XT and Medtronic CoreValve. The TRISKELE valves demonstrated a global hydrodynamic performance comparable or superior to the controls with significant reduction in paravalvular leakage. The TRISKELE valve exhibits enhanced anchoring and improved sealing. The valve is currently under preclinical investigation.
Weiner, H L; Constantini, S; Cohen, H; Wisoff, J H
1995-11-01
FROM THE RECORDS of approximately 1500 shunt operations performed between 1987 and 1992, we identified 37 adults between ages 38 and 86 years (mean, 70 yr) with the normal-pressure hydrocephalus (NPH) syndrome who underwent surgery by a single surgeon. Since 1990, we have routinely used a flow-regulated shunt system (Orbis-Sigma valve [OSV]; Cordis Corporation, Miami, FL) in these patients. In this study, we compared the OSV system with conventional differential-pressure (DP) shunt systems uniformly used before 1990. This series (n = 37) consisted of 62% men (n = 23) and 38% women (n = 14). We excluded all patients with hydrocephalus associated with central nervous system neoplasms, intracerebral hemorrhage, or trauma as well those with radiographically documented late-onset aqueductal stenosis. All patients presented with the NPH clinical syndrome, chiefly with magnetic gait. In addition, 75% of patients experienced cognitive loss and 59% experienced urinary incontinence. The mean duration of preoperative symptoms was 35 months (range, 7-120 mo). Eight patients (22%) had undergone previous shunting procedures before referral to our service. A total of 89 shunt operations were performed in the 37 patients. Using actuarial methods and controlling for a history of prior shunt surgery, we found no significant difference in the time to initial malfunction (shunt survival) between the OSV and the DP shunts. There were three subdural hematomas and one infection in the OSV group compared with no complications in the DP valve group (P = 0.11). Thirty-six patients were available for follow-up, at a mean of 14 months after surgery. Nearly 90% of all patients experienced improvement in gait after shunting, regardless of the valve system that was used. There was one unrelated death. Realizing the limitations of a retrospective analysis and on the basis of the limited number of patients in this study, we conclude that using actuarial methods, we found no significant difference in shunt survival when comparing the OSV with the standard DP valve shunt systems with antisiphon devices in patients with NPH. Contrary to previous reports, the OSV is not free of overdrainage complications. Most patients (89%) with the NPH syndrome who primarily presented with gait disorder experienced significant improvement in gait after either OSV or DP shunting procedures when selected for surgery on the basis of the clinical syndrome and confirmatory radiographic data.
Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link
NASA Technical Reports Server (NTRS)
Hartenstine, John; Anderson, William G.; Walker, Kara; Dussinger, Pete
2012-01-01
Future lunar landers and rovers will require variable thermal links that allow for heat rejection during the lunar daytime and passively prevent heat rejection during the lunar night. During the lunar day, the thermal management system must reject the waste heat from the electronics and batteries to maintain them below the maximum acceptable temperature. During the lunar night, the heat rejection system must either be shut down or significant amounts of guard heat must be added to keep the electronics and batteries above the minimum acceptable temperature. Since guard heater power is unfavorable because it adds to system size and complexity, a variable thermal link is preferred to limit heat removal from the electronics and batteries during the long lunar night. Conventional loop heat pipes (LHPs) can provide the required variable thermal conductance, but they still consume electrical power to shut down the heat transfer. This innovation adds a thermal control valve (TCV) and a bypass line to a conventional LHP that proportionally allows vapor to flow back into the compensation chamber of the LHP. The addition of this valve can achieve completely passive thermal control of the LHP, eliminating the need for guard heaters and complex controls.
Kiefer, Philipp; Noack, Thilo; Seeburger, Joerg; Hoyer, Alexandro; Linke, Axel; Mangner, Norman; Lehmkuhl, Lukas; Mohr, Friedrich Wilhelm; Holzhey, David
2017-12-01
Transcatheter mitral valve implantation (TMVI) is still in its infancy and is mainly limited to valve-in-valve or valve-in-ring implantations. We present the early experience with TMVI for severe calcified native MV stenosis. Between January 2014 and June 2015, 6 of 11 patients screened (mean age, 77.4 ± 6.3 years; 66% men) with severe native mitral valve (MV) stenosis (mean gradient [Pmean], 11.1 ± 2.1 mm Hg; mean effective orifice area [EOA], 0.9 ± 0.12 cm 2 ) underwent transcatheter MV replacement at our institution as a bailout procedure. Conventional surgical procedures were denied in all patients because of severe annular calcification and extensive comorbidities (mean logistic EuroScore, 31.4% ± 8.3%). The Edwards SAPIEN 3 (29 mm) (Edwards Lifesciences, Irvine, CA) was used in all cases. Procedural access was transapical in 5 cases and concomitant to aortic valve replacement through the left atrium through a sternotomy in 1 case. Initial implantation was successful in 100% of the cases. Because of early migration, 1 patient needed a valve-in-valve procedure. Postoperative echocardiography showed no residual mitral regurgitation in 4 cases (66%) and mild regurgitation in 2 cases (34%). Mean gradients were reduced to 4.2 ± 0.6 mm Hg (mean EOA, 2.8 ± 0.4 cm 2) . No patient had a stroke during hospitalization, and 30-day mortality was seen in 1 patient (17%) resulting from pneumonia. TMV implantation using the SAPIEN 3 aortic prosthesis in patients with heavy annular calcification is feasible and represents a reasonable bailout option for inoperable patients. However, several limitations need to be considered in this special patient population. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Valve repair in aortic regurgitation without root dilatation--aortic valve repair.
Lausberg, H F; Aicher, D; Kissinger, A; Langer, F; Fries, R; Schäfers, H-J
2006-02-01
Aortic valve repair was established in the context of aortic root remodeling. Variable results have been reported for isolated valve repair. We analyzed our experience with isolated valve repair and compared the results with those of aortic root remodeling. Between October 1995 and August 2003, isolated repair of the aortic valve was performed in 83 patients (REP), remodeling of the aortic valve in 175 patients (REMO). The demographics of the two groups were comparable (REP: mean age 54.4 +/- 20.7 yrs, male-female ratio 2.1 : 1; REMO: mean age 60.8 +/- 13.6 yrs, male-female ratio 2.4 : 1; p = ns). In both groups the number of bicuspid valves was comparable (REP: 41 %, REMO: 32 %; p = ns). All patients were followed by echocardiography for a cumulative follow-up of 8204 patient months (mean 32 +/- 23 months). Overall in-hospital mortality was 2.4 % in REP and 4.6 % in REMO ( p = 0.62). Systolic gradients were comparable in both groups (REP: 5.8 +/- 2.2, REMO: 6.5 +/- 3.1 mm Hg, p = 0.09). The mean degree of aortic regurgitation 12 months postoperatively was 0.8 +/- 0.7 after REP and 0.7 +/- 0.7 after REMO ( p = 0.29). Freedom from significant regurgitation (> or = II degrees ) after 5 years was 86 % in REP and 89 % in REMO ( p = 0.17). Freedom from re-operation after 5 years was 94.4 % in REP and 98.2 % in REMO ( p = 0.33). Aortic regurgitation without concomitant root dilatation can be treated effectively by aortic valve repair. The functional results are equivalent to those obtained with valve-preserving root replacement. Aortic valve repair appears to be an alternative to valve replacement in aortic regurgitation.
Lab-on-a-Disc Platform for Automated Chemical Cell Lysis.
Seo, Moo-Jung; Yoo, Jae-Chern
2018-02-26
Chemical cell lysis is an interesting topic in the research to Lab-on-a-Disc (LOD) platforms on account of its perfect compatibility with the centrifugal spin column format. However, standard procedures followed in chemical cell lysis require sophisticated non-contact temperature control as well as the use of pressure resistant valves. These requirements pose a significant challenge thereby making the automation of chemical cell lysis on an LOD extremely difficult to achieve. In this study, an LOD capable of performing fully automated chemical cell lysis is proposed, where a combination of chemical and thermal methods has been used. It comprises a sample inlet, phase change material sheet (PCMS)-based temperature sensor, heating chamber, and pressure resistant valves. The PCMS melts and solidifies at a certain temperature and thus is capable of indicating whether the heating chamber has reached a specific temperature. Compared to conventional cell lysis systems, the proposed system offers advantages of reduced manual labor and a compact structure that can be readily integrated onto an LOD. Experiments using Salmonella typhimurium strains were conducted to confirm the performance of the proposed cell lysis system. The experimental results demonstrate that the proposed system has great potential in realizing chemical cell lysis on an LOD whilst achieving higher throughput in terms of purity and yield of DNA thereby providing a good alternative to conventional cell lysis systems.
Trabeculectomy With Mitomycin C or Ahmed Valve Implantation in Eyes With Uveitic Glaucoma.
Bettis, Daniel I; Morshedi, Richard G; Chaya, Craig; Goldsmith, Jason; Crandall, Alan; Zabriskie, Norm
2015-01-01
To report and compare the results of trabeculectomy with mitomycin C (MMC) and Ahmed valve implantation in the management of uveitic glaucoma. The records of 41 eyes of 29 patients who underwent trabeculectomy with MMC or Ahmed valve implantation for uveitic glaucoma were retrospectively reviewed. Seventeen eyes underwent trabeculectomy with MMC, and 24 eyes underwent Ahmed valve implantation. Outcomes included postoperative intraocular pressure (IOP), percent reduction from preoperative IOP, postoperative number of medications, time to failure, and complications. Mean follow-up was 21.2 months in the trabeculectomy group and 23.8 months in the valve group (P=0.06). Mean IOP was reduced from 29.2 to 18.4 mm Hg in the trabeculectomy group (31.3%), compared with a reduction from 33.4 to 15.5 mm Hg in the Ahmed valve group (42.7%, P=0.53). Postoperatively, 1.76 medications were used in the trabeculectomy group, compared with 1.83 medications in the Ahmed valve group (P=0.89). Cumulative success at 1 year was 66.7% in the trabeculectomy group, compared with 100% in the Ahmed valve group (P=0.02). Mean time to failure was 8.36 months with trabeculectomy, and 21.8 months with Ahmed valve (P=0.02). Complications in both groups were typically rare and self-limited, with recurrent inflammation being most common. Although both trabeculectomy with MMC and Ahmed valve implantation are reasonable surgical options in the management of uncontrolled uveitic glaucoma, Ahmed valve implantation was associated with higher cumulative success rate at 1 year and a longer mean time to failure.
Nuclear radiation actuated valve
Christiansen, David W.; Schively, Dixon P.
1985-01-01
A nuclear radiation actuated valve for a nuclear reactor. The valve has a valve first part (such as a valve rod with piston) and a valve second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics. The valve's first part is positioned to receive nuclear radiation from the nuclear reactor's fuel region. The valve's second part is positioned so that its nuclear radiation induced swelling is different from that of the valve's first part. The valve's second part also is positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system.
Neethling, W M; Papadimitriou, J M; Swarts, E; Hodge, A J
2000-06-01
Valve related factors and patient related factors are responsible for calcification of valvular bioprostheses. Recent studies showed different donor and recipient species have different influences on the total calcification rate of bioprostheses. This study was performed to evaluate and compare Kangaroo aortic valve leaflets with porcine aortic valve leaflets. Experimental design. Prospective study. Setting. Cardio-thoracic experimental research of a university department. Glutaraldehyde-fixed Kangaroo and porcine valve leaflets were evaluated in vitro according to valve geometry (internal diameter and leaflet thickness), morphology (light and electron microscopy) and tensile strength. In vivo evaluation consisted of implantation in a rat model for 8 weeks, Von Kossa stain for calcium and atomic absorption spectrophotometry for total extractable calcium content. Kangaroo valves indicated a smaller internal valve diameter as well as a thinner valve leaflet (p<0.01, ANOVA) at corresponding body weight, less proteoglycan spicules in the fibrosa, increased elasticity (p<0.05) and low calcification potential (p<0.01, confidence interval 95%). Kangaroo aortic valve leaflets have different valvular qualities compared to porcine valve tissue. Kangaroo valve leaflets are significantly superior to porcine valve leaflets as far as calcification is concerned. These results are encouraging and suggest further in vivo evaluation in a larger animal model before clinical application can be considered.
Faraji, Reza; Behjati-Ardakani, Mostafa; Moshtaghioun, Seyed Mohammad; Kalantar, Seyed Mehdi; Namayandeh, Seyedeh Mahdieh; Soltani, Mohammadhossien; Emami, Mahmood; Zandi, Hengameh; Firoozabadi, Ali Dehghani; Kazeminasab, Mahmood; Ahmadi, Nastaran; Sarebanhassanabadi, Mohammadtaghi
2018-02-01
Broad-range bacterial rDNA polymerase chain reaction (PCR) followed by sequencing may be identified as the etiology of infective endocarditis (IE) from surgically removed valve tissue; therefore, we reviewed the value of molecular testing in identifying organisms' DNA in the studies conducted until 2016. We searched Google Scholar, Scopus, ScienceDirect, Cochrane, PubMed, and Medline electronic databases without any time limitations up to December 2016 for English studies reporting microorganisms involved in infective endocarditis microbiology using PCR and real-time PCR. Most studies were prospective. Eleven out of 12 studies used valve tissue samples and blood cultures while only 1 study used whole blood. Also, 10 studies used the molecular method of PCR while 2 studies used real-time PCR. Most studies used 16S rDNA gene as the target gene. The bacteria were identified as the most common microorganisms involved in infective endocarditis. Streptococcus spp. and Staphylococcus spp. were, by far, the most predominant bacteria detected. In all studies, PCR and real-time PCR identified more pathogens than blood and tissue cultures; moreover, the sensitivity and specificity of PCR and real-time PCR were more than cultures in most of the studies. The highest sensitivity and specificity were 96% and 100%, respectively. The gram positive bacteria were the most frequent cause of infective endocarditis. The molecular methods enjoy a greater sensitivity compared to the conventional blood culture methods; yet, they are applicable only to the valve tissue of the patients undergoing cardiac valve surgery. Copyright © 2017. Published by Elsevier Taiwan.
Scanlan, Adam B; Nguyen, Alex V; Ilina, Anna; Lasso, Andras; Cripe, Linnea; Jegatheeswaran, Anusha; Silvestro, Elizabeth; McGowan, Francis X; Mascio, Christopher E; Fuller, Stephanie; Spray, Thomas L; Cohen, Meryl S; Fichtinger, Gabor; Jolley, Matthew A
2018-03-01
Mastering the technical skills required to perform pediatric cardiac valve surgery is challenging in part due to limited opportunity for practice. Transformation of 3D echocardiographic (echo) images of congenitally abnormal heart valves to realistic physical models could allow patient-specific simulation of surgical valve repair. We compared materials, processes, and costs for 3D printing and molding of patient-specific models for visualization and surgical simulation of congenitally abnormal heart valves. Pediatric atrioventricular valves (mitral, tricuspid, and common atrioventricular valve) were modeled from transthoracic 3D echo images using semi-automated methods implemented as custom modules in 3D Slicer. Valve models were then both 3D printed in soft materials and molded in silicone using 3D printed "negative" molds. Using pre-defined assessment criteria, valve models were evaluated by congenital cardiac surgeons to determine suitability for simulation. Surgeon assessment indicated that the molded valves had superior material properties for the purposes of simulation compared to directly printed valves (p < 0.01). Patient-specific, 3D echo-derived molded valves are a step toward realistic simulation of complex valve repairs but require more time and labor to create than directly printed models. Patient-specific simulation of valve repair in children using such models may be useful for surgical training and simulation of complex congenital cases.
Exploratory assessment of left ventricular strain–volume loops in severe aortic valve diseases
Hulshof, Hugo G.; van Dijk, Arie P.; George, Keith P.; Hopman, Maria T. E.; Thijssen, Dick H. J.
2017-01-01
Key points Severe aortic valve diseases are common cardiac abnormalities that are associated with poor long‐term survival.Before any reduction in left ventricular (LV) function, the left ventricle undergoes structural remodelling under the influence of changing haemodynamic conditions.In this study, we combined temporal changes in LV structure (volume) with alterations in LV functional characteristics (strain, ԑ) into a ԑ–volume loop, in order to provide novel insight into the haemodynamic cardiac consequences of aortic valve diseases in those with preserved LV ejection fraction.We showed that our novel ԑ–volume loop and the specific loop characteristics provide additional insight into the functional and mechanical haemodynamic consequences of severe aortic valve diseases (with preserved LV ejection fraction).Finally, we showed that the ԑ–volume loop characteristics provide discriminative capacity compared with conventional measures of LV function. Abstract The purpose of this study was to examine left ventricular (LV) strain (ԑ)–volume loops to provide novel insight into the haemodynamic cardiac consequences of aortic valve stenosis (AS) and aortic valve regurgitation (AR). Twenty‐seven participants were retrospectively recruited: AR (n = 7), AS (n = 10) and control subjects (n = 10). Standard transthoracic echocardiography was used to obtain apical four‐chamber images to construct ԑ–volume relationships, which were assessed using the following parameters: early systolic ԑ (ԑ_ES); slope of ԑ–volume relationship during systole (Sslope); end‐systolic peak ԑ (peak ԑ); and diastolic uncoupling (systolic ԑ–diastolic ԑ at same volume) during early diastole (UNCOUP_ED) and late diastole (UNCOUP_LD). Receiver operating characteristic curves were used to determine the ability to detect impaired LV function. Although LV ejection fraction was comparable between groups, longitudinal peak ԑ was reduced compared with control subjects. In contrast, ԑ_ES and Sslope were lower in both pathologies compared with control subejcts (P < 0.01), but also different between AS and AR (P < 0.05). UNCOUP_ED and UNCOUP_LD were significantly higher in both patient groups compared with control subjects (P < 0.05). Receiver operating characteristic curves revealed that loop characteristics (AUC = 0.99, 1.00 and 1.00; all P < 0.01) were better able then peak ԑ (AUC = 0.75, 0.89 and 0.76; P = 0.06, <0.01 and 0.08, respectively) and LV ejection fraction (AUC = 0.56, 0.69 and 0.69; all P > 0.05) to distinguish AS vs control, AR vs control and AS vs AR groups, respectively. Temporal changes in ԑ–volume characteristics provide novel insight into the haemodynamic cardiac impact of AS and AR. Contrary to traditional measures (i.e. ejection fraction, peak ԑ), these novel measures successfully distinguish between the haemodynamic cardiac impact of AS and AR. PMID:28117492
Exploratory assessment of left ventricular strain-volume loops in severe aortic valve diseases.
Hulshof, Hugo G; van Dijk, Arie P; George, Keith P; Hopman, Maria T E; Thijssen, Dick H J; Oxborough, David L
2017-06-15
Severe aortic valve diseases are common cardiac abnormalities that are associated with poor long-term survival. Before any reduction in left ventricular (LV) function, the left ventricle undergoes structural remodelling under the influence of changing haemodynamic conditions. In this study, we combined temporal changes in LV structure (volume) with alterations in LV functional characteristics (strain, ԑ) into a ԑ-volume loop, in order to provide novel insight into the haemodynamic cardiac consequences of aortic valve diseases in those with preserved LV ejection fraction. We showed that our novel ԑ-volume loop and the specific loop characteristics provide additional insight into the functional and mechanical haemodynamic consequences of severe aortic valve diseases (with preserved LV ejection fraction). Finally, we showed that the ԑ-volume loop characteristics provide discriminative capacity compared with conventional measures of LV function. The purpose of this study was to examine left ventricular (LV) strain (ԑ)-volume loops to provide novel insight into the haemodynamic cardiac consequences of aortic valve stenosis (AS) and aortic valve regurgitation (AR). Twenty-seven participants were retrospectively recruited: AR (n = 7), AS (n = 10) and control subjects (n = 10). Standard transthoracic echocardiography was used to obtain apical four-chamber images to construct ԑ-volume relationships, which were assessed using the following parameters: early systolic ԑ (ԑ_ES); slope of ԑ-volume relationship during systole (Sslope); end-systolic peak ԑ (peak ԑ); and diastolic uncoupling (systolic ԑ-diastolic ԑ at same volume) during early diastole (UNCOUP_ED) and late diastole (UNCOUP_LD). Receiver operating characteristic curves were used to determine the ability to detect impaired LV function. Although LV ejection fraction was comparable between groups, longitudinal peak ԑ was reduced compared with control subjects. In contrast, ԑ_ES and Sslope were lower in both pathologies compared with control subejcts (P < 0.01), but also different between AS and AR (P < 0.05). UNCOUP_ED and UNCOUP_LD were significantly higher in both patient groups compared with control subjects (P < 0.05). Receiver operating characteristic curves revealed that loop characteristics (AUC = 0.99, 1.00 and 1.00; all P < 0.01) were better able then peak ԑ (AUC = 0.75, 0.89 and 0.76; P = 0.06, <0.01 and 0.08, respectively) and LV ejection fraction (AUC = 0.56, 0.69 and 0.69; all P > 0.05) to distinguish AS vs control, AR vs control and AS vs AR groups, respectively. Temporal changes in ԑ-volume characteristics provide novel insight into the haemodynamic cardiac impact of AS and AR. Contrary to traditional measures (i.e. ejection fraction, peak ԑ), these novel measures successfully distinguish between the haemodynamic cardiac impact of AS and AR. © 2017 The Authors. The Journal of Physiology © 2017 The Physiological Society.
Obstructive Thebesian valve: anatomical study and implications for invasive cardiologic procedures.
Ghosh, Sanjib Kumar; Raheja, Shashi; Tuli, Anita
2014-03-01
Thebesian valve is the embryological remnant of the right sinoatrial valve, guarding the coronary sinus (CS) ostium. Advanced invasive and interventional cardiac diagnostic and management tools involve cannulation of the CS ostium. The presence of obstructive Thebesian valves has been reported to lead to unsuccessful cannulation of the CS. We studied the morphology of the Thebesian valve and CS ostium to assess the possible impact of these structures on invasive cardiological procedures. One hundred fifty randomly selected human cadaveric heart specimens fixed in 10% formalin were dissected in the customary routine manner. The Thebesian valves were classified according to their shape as semilunar/fenestrated/biconcave band like and according to their composition as membranous/fibromuscular/fibrous/muscular, and the extent to which the valve covered the CS ostium was also noted. An obstructive Thebesian valve that could interfere with the cannulation of the CS was defined as non-fenestrated (semilunar/biconcave band like) and non-membranous (fibromuscular/fibrous/muscular) valves covering >75% of the CS ostium. Thebesian valves were present in 118 (79%) heart specimens, of which 27 (18%) met the criteria of being obstructive. Semilunar was the most common type of Thebesian valve in terms of shape and was observed in 65 (65/118; 55%) hearts. This type was associated with the least mean craniocaudal (7.9±0.6 mm) and mean transverse (6.25±0.6 mm) diameters of the CS ostium. The mean craniocaudal diameter of the CS ostium (9.4±2.1 mm) was significantly larger (p=0.004) than the mean transverse diameter (7.15±1.5 mm) in specimens with Thebesian valves, and the cranial margin of the CS ostium was free from any attachment of the Thebesian valve in all the types observed (in terms of shape). Hence, attempts to direct the tip of the catheter toward the cranial margin of the CS ostium under direct vision may lead to successful cannulation of the same when conventional techniques have been unsuccessful because of the presence of an obstructive Thebesian valve.
Kochhar, Puneet K; Zutshi, V; Shamsunder, S; Batra, S; Ghosh, P
2011-01-01
Congenital bicuspid aortic valve with severe aortic stenosis (AS) is a rare condition (3-6% of patients with congenital heart disease). Pregnancy in these patients carries a high risk of maternal and fetal mortality. With advancing gestational age, these women may develop cardiac failure due to increased cardiorespiratory requirements. When medical therapy proves insufficient, cardiac surgery becomes mandatory to save the patient's life. Balloon valvuloplasty is only palliative treatment, the duration of benefit being only 6 months. Valve replacement is thus recommended. Cardiopulmonary bypass (CPB) surgery with valve replacement has been reported to carry a lower risk of maternal mortality (1.5-13%) but a very high fetal risk (16-40%). This paper reports the case of a 30-year-old primigravida with severe AS with bicuspid aortic valve and pulmonary congestion clinically uncontrolled, in whom CPB surgery and aortic valve replacement was performed as an emergency procedure, along with a lower segment Caesarian section. The outcome of unrelieved severe symptomatic AS in pregnancy is poor. Multidisciplinary management is important to avoid deterioration in cardiac performance in parturients with severe AS. CPB during pregnancy carries a high risk to the fetus. Therefore, open heart surgery during pregnancy should be advised only in extreme emergencies (ie, heart failure refractory to conventional therapy).
Barbero, Cristina; Ricci, Davide; Cura Stura, Erik; Pellegrini, Augusto; Marchetto, Giovanni; ElQarra, Suad; Boffini, Massimo; Passera, Roberto; Valentini, Maria Consuelo; Rinaldi, Mauro
2017-02-21
Recent data have highlighted a higher rate of neurological injuries in minimal invasive mitral valve surgery (MIMVS) compared with the standard sternotomy approach; therefore, the role of specific clamping techniques and perfusion strategies on the occurrence of this complication is a matter of discussion in the medical literature. The purpose of this trial is to prospectively evaluate major, minor and silent neurological events in patients undergoing right mini-thoracotomy mitral valve surgery using retrograde perfusion and an endoaortic clamp or a transthoracic clamp. A prospective, blinded, randomized controlled study on the rate of neurological embolizations during MIMVS started at the University of Turin in June 2014. Major, minor and silent neurological events are being investigated through standard neurological evaluation and magnetic resonance imaging assessment. The magnetic resonance imaging protocol includes conventional sequences for the morphological and quantitative assessment and nonconventional sequences for the white matter microstructural evaluation. Imaging studies are performed before surgery as baseline assessment and on the third postoperative day and, in patients who develop postoperative ischemic lesions, after 6 months. Despite recent concerns raised about the endoaortic setting with retrograde perfusion, we expect to show equivalence in terms of neurological events of this technique compared with the transthoracic clamp in a selected cohort of patients. With the first results expected in December 2016 the findings would be of help in confirming the efficacy and safety of MIMVS. ClinicalTrials.gov, Identifier: NCT02818166 . Registered on 8 February 2016 - trial retrospectively registered.
Adjustable shunt valve-induced magnetic resonance imaging artifact: a comparative study.
Toma, Ahmed K; Tarnaris, Andrew; Grieve, Joan P; Watkins, Laurence D; Kitchen, Neil D
2010-07-01
In this paper, the authors' goal was to compare the artifact induced by implanted (in vivo) adjustable shunt valves in spin echo, diffusion weighted (DW), and gradient echo MR imaging pulse sequences. The MR images obtained in 8 patients with proGAV and 6 patients with Strata II adjustable shunt valves were assessed for artifact areas in different planes as well as the total volume for different pulse sequences. Artifacts induced by the Strata II valve were significantly larger than those induced by proGAV valve in spin echo MR imaging pulse sequence (29,761 vs 2450 mm(3) on T2-weighted fast spin echo, p = 0.003) and DW images (100,138 vs 38,955 mm(3), p = 0.025). Artifacts were more marked on DW MR images than on spin echo pulse sequence for both valve types. Adjustable valve-induced artifacts can conceal brain pathology on MR images. This should influence the choice of valve implantation site and the type of valve used. The effect of artifacts on DW images should be highlighted pending the development of less MR imaging artifact-inducing adjustable shunt valves.
Pseudospin Electronics in Phosphorene Nanoribbons
Soleimanikahnoj, S.; Knezevic, I.
2017-12-19
Zigzag phosphorene nanoribbons are metallic owing to the edge states, whose energies are inside the gap and far from the bulk bands. We show that -- through electrical manipulation of edge states -- electron propagation can be restricted to one of the ribbon edges or, in case of bilayer phosphorene nanoribbons, to one of the layers. This finding implies that edge and layer can be regarded as tunable equivalents of the spin-one-half degree of freedom, i.e., the pseudospin. In both layer- and edge-pseudospin schemes, we propose and characterize a pseudospin field-effect transistor, which can generate pseudospin-polarized current. Also, we proposemore » edge- and layer-pseudospin valves that operate analogously to conventional spin valves. The performance of valves in each pseudospin scheme is benchmarked by the pseudomagnetoresistance (PMR) ratio. The edge-pseudospin valve shows a nearly perfect PMR, with remarkable robustness against device parameters and disorder. Furthermore, these results may initiate new developments in pseudospin electronics.« less
Spin valves with spin-engineered domain-biasing scheme
NASA Astrophysics Data System (ADS)
Lu, Z. Q.; Pan, G.
2003-06-01
Synthetic spin-filter spin valves with spin-engineered biasing scheme "sub/Ta/NiFe/IrMn/NiFe/NOL/Cu1/CoFe/Cu2/CoFe/Ru/CoFe/IrMn/Ta" were developed. In the structure, the orthogonal magnetic configuration for biasing and pinning field was obtained by one-step magnetic annealing process by means of spin flop, which eliminated the need for two antiferromagnetic materials with distinctively different blocking temperatures and two-step magnetic annealing as in conventional exchange biasing scheme. The longitudinal domain biasing of spin valves was achieved by using interlayer coupling field through Cu1 spacer. By adjusting the thickness of the Cu1 layer, the interlayer coupling biasing field can provide domain stabilization and was sufficiently strong to constrain the magnetization in coherent rotation. This can prevent Barkhausen noises associated with magnetization reversal. We report here a proof of concept study of such a domain-biasing scheme, which has its important technological applications in nanoscale spin valve and magnetic tunneling junction read heads and other spintronic devices.
Moreira, Ricardo; Velz, Thaddaeus; Alves, Nuno; Gesche, Valentine N.; Malischewski, Axel; Schmitz-Rode, Thomas; Frese, Julia
2015-01-01
Transcatheter aortic valve implantation of (nonviable) bioprosthetic valves has been proven a valid alternative to conventional surgical implantation in patients at high or prohibitive mortality risk. In this study we present the in vitro proof-of-principle of a newly developed tissue-engineered heart valve for minimally invasive implantation, with the ultimate aim of adding the unique advantages of a living tissue with regeneration capabilities to the continuously developing transcatheter technologies. The tube-in-stent is a fibrin-based tissue-engineered valve with a tubular leaflet design. It consists of a tubular construct sewn into a self-expandable nitinol stent at three commissural attachment points and along a circumferential line so that it forms three coaptating leaflets by collapsing under diastolic back pressure. The tubular constructs were molded with fibrin and human umbilical vein cells. After 3 weeks of conditioning in a bioreactor, the valves were fully functional with unobstructed opening (systolic phase) and complete closure (diastolic phase). Tissue analysis showed a homogeneous cell distribution throughout the valve's thickness and deposition of collagen types I and III oriented along the longitudinal direction. Immunohistochemical staining against CD31 and scanning electron microscopy revealed a confluent endothelial cell layer on the surface of the valves. After harvesting, the valves underwent crimping for 20 min to simulate the catheter-based delivery. This procedure did not affect the valvular functionality in terms of orifice area during systole and complete closure during diastole. No influence on the extracellular matrix organization, as assessed by immunohistochemistry, nor on the mechanical properties was observed. These results show the potential of combining tissue engineering and minimally invasive implantation technology to obtain a living heart valve with a simple and robust tubular design for transcatheter delivery. The effect of the in vivo remodeling on the functionality of the tube-in-stent valve remains to be tested. PMID:25380414
Schuhbaeck, Annika; Weingartner, Christina; Arnold, Martin; Schmid, Jasmin; Pflederer, Tobias; Marwan, Mohamed; Rixe, Johannes; Nef, Holger; Schneider, Christian; Lell, Michael; Uder, Michael; Ensminger, Stephan; Feyrer, Richard; Weyand, Michael; Achenbach, Stephan
2015-07-01
The geometry of the aortic annulus and implanted transcatheter aortic valve prosthesis might influence valve function. We investigated the influence of valve type and aortic valve calcification on post-implant geometry of catheter-based aortic valve prostheses. Eighty consecutive patients with severe aortic valve stenosis (mean age 82 ± 6 years) underwent computed tomography before and after TAVI. Aortic annulus diameters were determined. Influence of prosthesis type and degree of aortic valve calcification on post-implant eccentricity were analysed. Aortic annulus eccentricity was reduced in patients after TAVI (0.21 ± 0.06 vs. 0.08 ± 0.06, p<0.0001). Post-TAVI eccentricity was significantly lower in 65 patients following implantation of a balloon-expandable prosthesis as compared to 15 patients who received a self-expanding prosthesis (0.06 ± 0.05 vs. 0.15 ± 0.07, p<0.0001), even though the extent of aortic valve calcification was not different. After TAVI, patients with a higher calcium amount retained a significantly higher eccentricity compared to patients with lower amounts of calcium. Patients undergoing TAVI with a balloon-expandable prosthesis show a more circular shape of the implanted prosthesis as compared to patients with a self-expanding prosthesis. Eccentricity of the deployed prosthesis is affected by the extent of aortic valve calcification. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Toma, Milan; Einstein, Daniel R.; Bloodworth, Charles H.; Cochran, Richard P.; Yoganathan, Ajit P.; Kunzelman, Karyn S.
2016-01-01
Over the years, three-dimensional models of the mitral valve have generally been organized around a simplified anatomy. Leaflets have been typically modeled as membranes, tethered to discrete chordae typically modeled as one-dimensional, non-linear cables. Yet, recent, high-resolution medical images have revealed that there is no clear boundary between the chordae and the leaflets. In fact, the mitral valve has been revealed to be more of a webbed structure whose architecture is continuous with the chordae and their extensions into the leaflets. Such detailed images can serve as the basis of anatomically accurate, subject-specific models, wherein the entire valve is modeled with solid elements that more faithfully represent the chordae, the leaflets, and the transition between the two. These models have the potential to enhance our understanding of mitral valve mechanics, and to re-examine the role of the mitral valve chordae, which heretofore have been considered to be “invisible” to the fluid and to be of secondary importance to the leaflets. However, these new models also require a rethinking of modeling assumptions. In this study, we examine the conventional practice of loading the leaflets only and not the chordae in order to study the structural response of the mitral valve apparatus. Specifically, we demonstrate that fully resolved 3D models of the mitral valve require a fluid-structure interaction analysis to correctly load the valve even in the case of quasi-static mechanics. While a fluid-structure interaction mode is still more computationally expensive than a structural-only model, we also show that advances in GPU computing have made such models tractable. PMID:27342229
Toma, Milan; Einstein, Daniel R; Bloodworth, Charles H; Cochran, Richard P; Yoganathan, Ajit P; Kunzelman, Karyn S
2017-04-01
Over the years, three-dimensional models of the mitral valve have generally been organized around a simplified anatomy. Leaflets have been typically modeled as membranes, tethered to discrete chordae typically modeled as one-dimensional, non-linear cables. Yet, recent, high-resolution medical images have revealed that there is no clear boundary between the chordae and the leaflets. In fact, the mitral valve has been revealed to be more of a webbed structure whose architecture is continuous with the chordae and their extensions into the leaflets. Such detailed images can serve as the basis of anatomically accurate, subject-specific models, wherein the entire valve is modeled with solid elements that more faithfully represent the chordae, the leaflets, and the transition between the two. These models have the potential to enhance our understanding of mitral valve mechanics and to re-examine the role of the mitral valve chordae, which heretofore have been considered to be 'invisible' to the fluid and to be of secondary importance to the leaflets. However, these new models also require a rethinking of modeling assumptions. In this study, we examine the conventional practice of loading the leaflets only and not the chordae in order to study the structural response of the mitral valve apparatus. Specifically, we demonstrate that fully resolved 3D models of the mitral valve require a fluid-structure interaction analysis to correctly load the valve even in the case of quasi-static mechanics. While a fluid-structure interaction mode is still more computationally expensive than a structural-only model, we also show that advances in GPU computing have made such models tractable. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia
2017-01-01
Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in the clinical features of patients receiving a biological valve compared to patients receiving a mechanical valve. A large, multicenter retrospective study included in our meta-analysis suggested that any mortality risk of the biological valve group was significant higher than that of the mechanical valve group. However, the risk was no different after risk was adjusted. So, we thought the reason for this result may be related to the characteristics of the patient rather than valve dysfunction. It is still necessary to future randomized studies to verify this conclusion.
Pseudo 1-D Micro/Nanofluidic Device for Exact Electrokinetic Responses.
Kim, Junsuk; Kim, Ho-Young; Lee, Hyomin; Kim, Sung Jae
2016-06-28
Conventionally, a 1-D micro/nanofluidic device, whose nanochannel bridged two microchannels, was widely chosen in the fundamental electrokinetic studies; however, the configuration had intrinsic limitations of the time-consuming and labor intensive tasks of filling and flushing the microchannel due to the high fluidic resistance of the nanochannel bridge. In this work, a pseudo 1-D micro/nanofluidic device incorporating air valves at each microchannel was proposed for mitigating these limitations. High Laplace pressure formed at liquid/air interface inside the microchannels played as a virtual valve only when the electrokinetic operations were conducted. The identical electrokinetic behaviors of the propagation of ion concentration polarization layer and current-voltage responses were obtained in comparison with the conventional 1-D micro/nanofluidic device by both experiments and numerical simulations. Therefore, the suggested pseudo 1-D micro/nanofluidic device owned not only experimental conveniences but also exact electrokinetic responses.
Murphy, David J; McEvoy, Sinead H; Iyengar, Sri; Feuchtner, Gudrun; Cury, Ricardo C; Roobottom, Carl; Baumueller, Stephan; Alkadhi, Hatem; Dodd, Jonathan D
2014-08-01
To assess the diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT for bicuspid aortic valves. The standard axial chest CT scans of 20 patients with known bicuspid aortic valves were blindly, randomly analyzed for (i) the appearance of the valve cusps, (ii) the largest aortic sinus area, (iii) the longest aortic cusp length, (iv) the thickest aortic valve cusp and (v) valve calcification. A second blinded reader independently analyzed the appearance of the valve cusps. Forty-two age- and sex-matched patients with known tricuspid aortic valves were used as controls. Retrospectively ECG-gated cardiac CT multiphase reconstructions of the aortic valve were used as the gold-standard. Fourteen (21%) scans were scored as unevaluable (7 bicuspid, 7 tricuspid). Of the remainder, there were 13 evaluable bicuspid valves, ten of which showed an aortic valve line sign, while the remaining three showed a normal Mercedes-Benz appearance owing to fused valve cusps. The 35 evaluable tricuspid aortic valves all showed a normal Mercedes-Benz appearance (P=0.001). Kappa analysis=0.62 indicating good interobserver agreement for the aortic valve cusp appearance. Aortic sinus areas, aortic cusp lengths and aortic cusp thicknesses of ≥ 3.8 cm(2), 3.2 cm and 1.6mm respectively on standard axial chest CT best distinguished bicuspid from tricuspid aortic valves (P<0.0001 for all). Of evaluable scans, the sensitivity, specificity, positive and negative predictive values of standard axial chest CT in diagnosing bicuspid aortic valves was 77% (CI 0.54-1.0), 100%, 100% and 70% respectively. The aortic valve is evaluable in approximately 80% of standard chest 64-slice CT scans. Bicuspid aortic valves may be diagnosed on evaluable scans with good diagnostic accuracy. An aortic valve line sign, enlarged aortic sinuses and elongated, thickened valve cusps are specific CT features. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Valve assembly for internal combustion engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wakeman, R.J.; Shea, S.F.
1989-09-05
This patent describes an improvement in a valve assembly for an internal combustion engine of the type including a valve having a valve stem, a valve guideway for mounting this valve for reciprocal strokes between opened and seated position, and spring means for biasing the valve into the seated position. The improvement comprising a valve spool of greater cross-sectional diameter as compared to the valve stem, and a valve spool guideway within which the valve spool is movable during the strokes of the valve, an upper surface of the valve spool and a portion of the spool guideway collectively establishingmore » a damper chamber which varies in volume during the valve strokes. a feed passage for introducing oil into the damper chamber, and a bleed passage for discharging oil from the damper chamber. The bleed passages each laterally opening into the valve spool guideway.« less
Um, Kevin J; Mcclure, Graham R; Belley-Cote, Emilie P; Gupta, Saurabh; Bouhout, Ismail; Lortie, Hugo; Alraddadi, Hatim; Alsagheir, Ali; Bossard, Matthias; Mcintyre, William F; Lengyel, Alexandra; Eikelboom, John W; Ouzounian, Maral; Chu, Michael W; Parry, Dominic; El-Hamamsy, Ismail; Whitlock, Richard P
2018-06-01
Life expectancy in young adults undergoing mechanical or bioprosthetic aortic valve replacement (AVR) may be reduced by up to 20 years compared to age matched controls. The Ross procedure is a durable, anticoagulation-sparing alternative. We performed a systematic review and meta-analysis to compare the valve hemodynamics of the Ross procedure versus other AVR. We searched Cochrane CENTRAL, MEDLINE and EMBASE from inception to February 2017 for randomized controlled trials (RCTs) and observational studies (n≥10 Ross). Independently and in duplicate, we performed title and abstract screening, full-text eligibility assessment, and data collection. We evaluated the risk of bias with the Cochrane and CLARITY tools, and the quality of evidence with the GRADE framework. We identified 2 RCTs and 13 observational studies that met eligibility criteria (N.=1412). In observational studies, the Ross procedure was associated with a lower mean aortic gradient at discharge (MD -9 mmHg, 95% CI: -13 to -5, P<0.0001, I2=97%) and latest follow-up (MD -5 mmHg, 95% CI: -7 to -3, P<0.0001, I2=92%). There was no significant difference in the incidence of severe aortic regurgitation at latest follow-up (RR 1.3, 95% CI: 0.3 to 5.8, P=0.70, I2=30%). In RCTs, the Ross procedure was associated with a lower mean gradient at latest follow-up (MD -15 mmHg, 95% CI: -32 to 2, P=0.08, I2=99%). The mean pulmonic gradient for the Ross procedure was 18.0 mmHg (95% CI: 16 to 20, P<0.0001) at latest follow-up. The evidence for all outcomes from observational studies was deemed to be of very low quality, while the evidence from RCTs was downgraded for imprecision and moderately serious risk of bias. Compared to conventional AVR, the Ross procedure was associated with better aortic valve hemodynamics. Future studies should evaluate the impact of the Ross procedure on exercise capacity and quality of life.
Interventional valve surgery: building a team and working together.
Ruel, Marc; Dickie, Sean; Chow, Benjamin J W; Labinaz, Marino
2010-01-01
Transcatheter aortic valve implantation (TAVI) is a new modality that may change the therapeutic landscape in the management of aortic valve stenosis. Despite the excellent results of surgical aortic valve replacement, TAVI has the potential to revolutionize the treatment of elderly and high-risk patients with aortic stenosis. It therefore constitutes a new reality that cardiac surgeons have to acknowledge. As TAVI indications and techniques become better defined, the importance of a team approach to the implementation and performance of TAVI is becoming increasingly evident. The surgeon has a crucial role to play in the introduction, development, and sustainability of TAVI at any institution. In this article, we discuss the procedural technique involved in TAVI, as well as the cardiologist and heart surgeon individualities and team dynamics. We make a case for judicious team-based adoption of TAVI technologies, considering that evidence-based and health economics data are not yet available. We also illustrate how a team approach may lead to improved outcomes, better patient and institutional acceptance, and a better definition of the therapeutic niche of TAVI modalities, amid the excellent results of conventional aortic valve replacement surgery. Copyright © 2010 Elsevier Inc. All rights reserved.
A nonintrusive method for measuring the operating temperature of a solenoid-operated valve
NASA Astrophysics Data System (ADS)
Kryter, Robert C.
Experimental data are presented to show that the in-service operating temperature of a solenoid operated valve (SOV) can be inferred simply and nondisruptively by using the copper winding of the solenoid coil as a self-indicating, permanently available resistance thermometer. The principal merits of this approach include: (1) there is no need for an add-on temperature sensor, (2) the true temperature of a critical and likely the hottest, part of the SOV (namely, the electrical coil) is measured directly, (3) temperature readout can be provided at any location at which the SOV electrical lead wires are accessible (even though remote from the valve), (4) the SOV need not be disturbed (whether normally energized or deenergized) to measure its temperature in situ, and (5) the method is applicable to all types of SOVs, large and small, ac- and dc-powered. Laboratory tests comparing temperatures measured both by coil resistance and by a conventional thermometer placed in contact with the external surface of the potted solenoid coil indicate that temperature within the coil may be on the order of 40 C higher than that measured externally, a fact that is important to life-expectancy calculations made on the basis of Arrhenius theory. Field practicality is illustrated with temperature measurements made using this method on a SOV controlling the flow of refrigerant in a large chilled-water air-conditioning system.
Turbulence downstream of subcoronary stentless and stented aortic valves.
Funder, Jonas Amstrup; Frost, Markus Winther; Wierup, Per; Klaaborg, Kaj-Erik; Hjortdal, Vibeke; Nygaard, Hans; Hasenkam, J Michael
2011-08-11
Regions of turbulence downstream of bioprosthetic heart valves may cause damage to blood components, vessel wall as well as to aortic valve leaflets. Stentless aortic heart valves are known to posses several hemodynamic benefits such as larger effective orifice areas, lower aortic transvalvular pressure difference and faster left ventricular mass regression compared with their stented counterpart. Whether this is reflected by diminished turbulence formation, remains to be shown. We implanted either stented pericardial valve prostheses (Mitroflow), stentless valve prostheses (Solo or Toronto SPV) in pigs or they preserved their native valves. Following surgery, blood velocity was measured in the cross sectional area downstream of the valves using 10MHz ultrasonic probes connected to a dedicated pulsed Doppler equipment. As a measure of turbulence, Reynolds normal stress (RNS) was calculated at two different blood pressures (baseline and 50% increase). We found no difference in maximum RNS measurements between any of the investigated valve groups. The native valve had significantly lower mean RNS values than the Mitroflow (p=0.004), Toronto SPV (p=0.008) and Solo valve (p=0.02). There were no statistically significant differences between the artificial valve groups (p=0.3). The mean RNS was significantly larger when increasing blood pressure (p=0.0006). We, thus, found no advantages for the stentless aortic valves compared with stented prosthesis in terms of lower maximum or mean RNS values. Native valves have a significantly lower mean RNS value than all investigated bioprostheses. Copyright © 2011 Elsevier Ltd. All rights reserved.
Nuclear-radiation-actuated valve. [Patent application; for increasing coolant flow to blanket
Christiansen, D.W.; Schively, D.P.
1982-01-19
The present invention relates to a breeder reactor blanket fuel assembly coolant system valve which increases coolant flow to the blanket fuel assembly to minimize long-term temperature increases caused by fission of fissile fuel created from fertile fuel through operation of the breeder reactor. The valve has a valve first part (such as a valve rod with piston) and a valve second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics. The valve's first part is positioned to receive nuclear radiation from the nuclear reactor's fuel region. The valve's second part is positioned so that its nuclear radiation induced swelling is different from that of the valve's first part. The valve's second part also is positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system.
Supercritical carbon dioxide-based sterilization of decellularized heart valves.
Hennessy, Ryan S; Jana, Soumen; Tefft, Brandon J; Helder, Meghana R; Young, Melissa D; Hennessy, Rebecca R; Stoyles, Nicholas J; Lerman, Amir
2017-02-01
The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile using histology, microbe culture and electron microscopy assays. The cusp tensile properties of supercritical carbon dioxide treated valves were higher compared to valves treated with other techniques. Superior sterility and integrity was found in the decellularized valves treated with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues.
An Inexpensive, Foolproof Apparatus for Flash Chromatography.
ERIC Educational Resources Information Center
Thompson, Wayne J.; Hanson, Bryan A.
1984-01-01
Describes a new, modified "flash chromatography" apparatus which overcomes difficulties found in conventional apparatus. For example, an expensive teflon pressure valve is not necessary in the modified version. The apparatus is suitable as an instructional tool in undergraduate courses. (JN)
Maltais, Simon; Tchantchaleishvili, Vahtang; Schaff, Hartzell V; Daly, Richard C; Suri, Rakesh M; Dearani, Joseph A; Topilsky, Yan; Stulak, John M; Joyce, Lyle D; Park, Soon J
2014-04-01
Patients with severe ischemic cardiomyopathy (left ventricular ejection fraction <25%) and severe ischemic mitral regurgitation have a poor survival with medical therapy alone. Left ventricular assist device as destination therapy is reserved for patients who are too high risk for conventional surgery. We evaluated our outcomes with conventional surgery within this population and the comparative effectiveness of these 2 therapies. We identified patients who underwent conventional surgery or left ventricular assist device as destination therapy for severe ischemic cardiomyopathy (left ventricular ejection fraction <25%) and severe mitral regurgitation. The era for conventional surgery spanned from 1993 to 2009 and from 2007 to 2011 for left ventricular assist device as destination therapy. We compared baseline patient characteristics and outcomes in terms of end-organ function and survival. A total of 88 patients were identified; 55 patients underwent conventional surgery (63%), and 33 patients (37%) received a left ventricular assist device as destination therapy. Patients who received left ventricular assist device as destination therapy had the increased prevalence of renal failure, inotrope dependency, and intra-aortic balloon support. Patients undergoing conventional surgery required longer ventilatory support, and patients receiving a left ventricular assist device required more reoperation for bleeding. Mortality rates were similar between the 2 groups at 30 days (7% in the conventional surgery group vs 3% in the left ventricular assist device as destination therapy group, P = .65) and at 1 year (22% in the conventional surgery group vs 15% in the left ventricular assist device as destination therapy group, P = .58). There was a trend toward improved survival in patients receiving a left ventricular assist device compared with the propensity-matched groups at 1 year (94% vs 71%, P = .171). The operative mortality and early survival after conventional surgery seem to be acceptable. For inoperable or prohibitive-risk patients, left ventricular assist device as destination therapy can be offered with similar outcomes. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia
2017-01-01
Objective Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Methods Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. Results A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). Conclusion The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in the clinical features of patients receiving a biological valve compared to patients receiving a mechanical valve. A large, multicenter retrospective study included in our meta-analysis suggested that any mortality risk of the biological valve group was significant higher than that of the mechanical valve group. However, the risk was no different after risk was adjusted. So, we thought the reason for this result may be related to the characteristics of the patient rather than valve dysfunction. It is still necessary to future randomized studies to verify this conclusion. PMID:28407024
Technical pitfalls and tips for the valve-in-valve procedure
2017-01-01
Transcatheter aortic valve implantation (TAVI) has emerged as a viable treatment modality for patients with severe aortic valve stenosis and multiple co-morbidities. More recent indications include the use of transcatheter heart valves (THV) to treat degenerated bioprosthetic surgical heart valves (SHV), which are failing due to stenosis or regurgitation. Valve-in-valve (VIV) procedures in the aortic position have been performed with a variety of THV devices, although the balloon-expandable SAPIEN valve platform (Edwards Lifesciences Ltd, Irvine, CA, USA) and self-expandable CoreValve platform (Medtronic Inc., MN, USA) have been used in majority of the patients. VIV treatment is appealing as it is less invasive than conventional surgery but optimal patient selection is vital to avoid complications such as malposition, residual high gradients and coronary obstruction. To minimize the risk of complications, thorough procedural planning is critical. The first step is identification of the degenerated SHV, including its model, size, fluoroscopic appearance. Although label size and stent internal diameter (ID) are provided by the manufacturer, it is important to note the true ID. The true ID is the ID of a SHV after the leaflets are mounted and helps determine the optimal size of THV. The second step is to determine the type and size of the THV. Although this is determined in the majority of the cases by user preference, in certain situations one THV may be more suitable than another. As the procedure is performed under fluoroscopy, the third step is to become familiarized with the fluoroscopic appearance of both the SHV and THV. This helps to determine the landmarks for optimal positioning, which in turn determines the gradients and fixation. The fourth step is to assess the risk of coronary obstruction. This is performed with either aortic root angiography or ECG-gated computerised tomography (CT). Finally, the route of approach must be carefully planned. Once these aspects are addressed, the procedure can be performed efficiently with a low risk of complications. PMID:29062752
Baumbach, Hardy; Rustenbach, Christian; Michaelsen, Jens; Hipp, Gernot; Pressmar, Markus; Leinweber, Marco; Franke, Ulrich Friedrich Wilhelm
2014-02-01
Minimally invasive extracorporeal circulation (MECC) technology was applied predominantly in coronary surgery. Data regarding the application of MECC in minimally invasive valve surgery are missing largely. Patients undergoing isolated minimally invasive mitral or aortic valve procedures were allocated either to conventional extracorporeal circulation (CECC) group (n = 63) or MECC group (n = 105), and their prospectively generated data were analyzed. Demographic data were comparable between the groups regarding age (CECC vs. MECC: 71.0 ± 7.5 vs. 66.2 ± 10.1 years, p = 0.091) and logistic EuroSCORE I (6.2 ± 2.5 vs. 5.4 ± 3.0, p = 0.707). Hospital mortality was one patient in each group (1.6 vs. 1.0%, p = 0.688). The levels of leukocytes were lower in the MECC group (11.6 ± 3.2 vs. 9.4 ± 4.3 109/L, p = 0.040). Levels of platelets (137.2 ± 45.5 vs. 152.4 ± 50.3 109/L, p = 0.015) and hemoglobin (103.3 ± 11.3 vs. 107.3 ± 14.7 g/L, p = 0.017) were higher in the MECC group. Renal function was better preserved (creatinine: 1.1 ± 0.4 vs. 0.9 ± 0.2 mg/dL, p = 0.019). We were able to validate shorter time of postoperative ventilation (9.5 ± 15.1 vs. 6.3 ± 3.4 h, p = 0.054) as well as significantly shorter intensive care unit (ICU) stay (1.8 ± 1.3 vs. 1.2 ± 1.0 d, p = 0.005) for MECC patients. The course of C-reactive protein did not differ between the groups. We were able to prove the feasibility of MECC even in minimally invasive performed mitral and aortic valve procedures. In addition, the use of MECC provides decreased platelet consumption and less hemodilution. The use of MECC in these selected patients lead to a shorter ventilation time and ICU stay. Georg Thieme Verlag KG Stuttgart · New York.
Aortic valve replacement using continuous suture technique in patients with aortic valve disease.
Choi, Jong Bum; Kim, Jong Hun; Park, Hyun Kyu; Kim, Kyung Hwa; Kim, Min Ho; Kuh, Ja Hong; Jo, Jung Ku
2013-08-01
The continuous suture (CS) technique has several advantages as a method for simple, fast, and secure aortic valve replacement (AVR). We used a simple CS technique without the use of a pledget for AVR and evaluated the surgical outcomes. Between October 2007 and 2012, 123 patients with aortic valve disease underwent AVR alone (n=28) or with other concomitant cardiac procedures (n=95), such as mitral, tricuspid, or aortic surgery. The patients were divided into two groups: the interrupted suture (IS) group (n=47), in which the conventional IS technique was used, and the CS group (n=76), in which the simple CS technique was used. There were two hospital deaths (1.6%), which were not related to the suture technique. There were no significant differences in cardiopulmonary bypass time or aortic cross-clamp time between the two groups for AVR alone or AVR with concomitant cardiac procedures. In the IS group, two patients had prosthetic endocarditis and one patient experienced significant perivalvular leak. These patients underwent reoperations. In the CS group, there were no complications related to the surgery. Postoperatively, the two groups had similar aortic valve gradients. The simple CS method is useful and secure for AVR in patients with aortic valve disease, and it may minimize surgical complications, as neither pledgets nor braided sutures are used.
Minimally invasive mitral valve surgery expands the surgical options for high-risks patients.
Petracek, Michael R; Leacche, Marzia; Solenkova, Natalia; Umakanthan, Ramanan; Ahmad, Rashid M; Ball, Stephen K; Hoff, Steven J; Absi, Tarek S; Balaguer, Jorge M; Byrne, John G
2011-10-01
A simplified minimally invasive mitral valve surgery (MIMVS) approach avoiding cross-clamping and cardioplegic myocardial arrest using a small (5 cm) right antero-lateral incision was developed. We hypothesized that, in high-risk patients and in patients with prior sternotomy, this approach would yield superior results compared to those predicted by the Society of Thoracic Surgeons (STS) algorithm for standard median sternotomy mitral valve surgery. Five hundred and four consecutive patients (249 males/255 females), median age 65 years (range 20-92 years) underwent MIMVS between 1/06 and 8/09. Median preoperative New York Heart Association function class was 3 (range 1-4). Eighty-two (16%) patients had an ejection fraction ≤35%. Forty-seven (9%) had a STS predicted mortality ≥10%. Under cold fibrillatory arrest (median temperature 28°C) without aortic cross-clamp, mitral valve repair (224/504, 44%) or replacement (280/504, 56%) was performed. Thirty-day mortality for the entire cohort was 2.2% (11/504). In patients with a STS predicted mortality ≥ 10% (range 10%-67%), the observed 30-day mortality was 4% (2/47), lower than the mean STS predicted mortality of 20%. Morbidity in this high-risk group was equally low: 1 of 47 (2%) patients underwent reexploration for bleeding, 1 of 47 (2%) patients suffered a permanent neurologic deficit, none had wound infection. The median length of stay was 8 days (range 1-68 days). This study demonstrates that MIMVS without aortic cross-clamp is reproducible with low mortality and morbidity rates. This approach expands the surgical options for high-risk patients and yields to superior results than the conventional median sternotomy approach.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalaskar, Vickey B; Szybist, James P; Splitter, Derek A
In recent years a number of studies have demonstrated that boosted operation combined with external EGR is a path forward for expanding the high load limit of homogeneous charge compression ignition (HCCI) operation with the negative valve overlap (NVO) valve strategy. However, the effects of fuel composition with this strategy have not been fully explored. In this study boosted HCCI combustion is investigated in a single-cylinder research engine equipped with direct injection (DI) fueling, cooled external exhaust gas recirculation (EGR), laboratory pressurized intake air, and a fully-variable hydraulic valve actuation (HVA) valve train. Three fuels with significant compositional differences aremore » investigated: regular grade gasoline (RON = 90.2), 30% ethanol-gasoline blend (E30, RON = 100.3), and 24% iso-butanol-gasoline blend (IB24, RON = 96.6). Results include engine loads from 350 to 800 kPa IMEPg for all fuels at three engine speeds 1600, 2000, and 2500 rpm. All operating conditions achieved thermal efficiency (gross indicated efficiency) between 38 and 47%, low NOX emissions ( 0.1 g/kWh), and high combustion efficiency ( 96.5%). Detailed sweeps of intake manifold pressure (atmospheric to 250 kPaa), EGR (0 25% EGR), and injection timing are conducted to identify fuel-specific effects. The major finding of this study is that while significant fuel compositional differences exist, in boosted HCCI operation only minor changes in operational conditions are required to achieve comparable operation for all fuels. In boosted HCCI operation all fuels were able to achieve matched load-speed operation, whereas in conventional SI operation the fuel-specific knock differences resulted in significant differences in the operable load-speed space. Although all fuels were operable in boosted HCCI, the respective air handling requirements are also discussed, including an analysis of the demanded turbocharger efficiency.« less
Roshdy, Hisham S; Meshrif, Amir M; El-Dosouky, Ibtesam I
2014-03-01
Conventional stenosis indexes poorly reflect the major hemodynamic consequence of mitral stenosis (MS). Valve resistance (VR) is a physiologic expression of stenosis. This study aimed to demonstrate whether the mitral valve resistance (MVR) and its changes, relate to restricted exercise capacity in patients with mild and moderate mitral stenosis. Twenty-four patients with rheumatic mild-to-moderate MS underwent transthoracic echocardiographic study (resting and dobutamine stress echocardiography [DSE]), divided into two groups; group I: symptomatic (12 patients) and group II: asymptomatic (12 patients). Mitral valve area (MVA), mean transmitral diastolic pressure gradient (TMPG), cardiac output (CO), and MVR were measured in all patients at rest and at peak DSE. Changes (∆) in MVA, TMPG, CO, and MVR were calculated. Data underwent statistical analysis. From resting to peak dobutamine infusion, the MVR significantly decreased from 111.4 ± 28.2 to 83.6 ± 27.0 dynes sec/cm(5) in group II (P < 0.001). The increase in MVR in group I (13.8 ± 10.3 dynes sec/cm(5)) compared with its reduction (-27.8 ± 15.6 dynes sec/cm(5)) in group II were highly significant different (P < 0.001). A reduction in MVR by less than 21.5 dynes sec/cm(5) at peak dobutamine infusion reflect a cutoff value considered to detect the hemodynamic significance of mild-to-moderate MS with a sensitivity of 92% and a specificity of 73%. The changes in the MVR can be used as a DSE parameter for expression of stenosis severity and to describe discrepancy in symptom status in patients with mild-to-moderate mitral stenosis. © 2013, Wiley Periodicals, Inc.
Belanger, Catherine; Gunther-Harrington, Catherine T; Nishimura, Satoko; Oldach, Maureen S; Fousse, Samantha L; Visser, Lance C; Stern, Joshua A
2018-04-01
We aimed to evaluate safety and efficacy of high-pressure balloon valvuloplasty (HPBVP) for treatment of canine severe pulmonary valve stenosis (PS). A secondary aim was to provide pre-procedure predictors of success. Twenty-five dogs. Prospective observational study. Dogs with severe PS (echocardiographically derived trans-pulmonary peak/maximum pressure gradient (EDPG) ≥80 mmHg) were recruited. All dogs underwent echocardiography before and 20-24hrs after HPBVP using a high-pressure balloon with rated burst pressures ranging from 12 to 18 ATM. Procedural success was defined as a post-HPBVP EDPG reduction of ≥50% or reduction into at least the moderate category of PS (50-79 mmHg). Optimal result was defined as a post-procedural EDPG ≤30 mmHg. Initial median (IQR) EDPG for all dogs was 96 (88, 127) mmHg with a post-operative median of 48 (36, 65) mmHg. The median EDPG reduction provided by HPBVP was 63% (39, 68); procedural success rate was 92% (23 dogs). Optimal results were achieved in 56% (14 dogs). There were no significant correlations between EDPG reduction and valve morphology (Type A and Type B) or severity of right ventricular hypertrophy. Pulmonary valve annulus diameter was the only echocardiographic variable that was significantly correlated to EDPG reduction (p = 0.02; r = -0.46). No dog experienced any anesthetic or surgical complications, and all patients survived the procedure. In this cohort of 25 dogs with severe PS, HPBVP was safe and effective. The procedural success rate and high number of optimal results achieved with HPBVP suggest future randomized controlled trials comparing HPBVP to conventional valvuloplasty are warranted. Copyright © 2018 Elsevier B.V. All rights reserved.
Kippenhan, D.O.
1962-09-25
An accurately controlled, pulse gas valve is designed capable of delivering output pulses which vary in length from one-tenth millisecond to one second or more, repeated at intervals of a few milliseconds or- more. The pulsed gas valve comprises a column formed of barium titanate discs mounted in stacked relation and electrically connected in parallel, with means for applying voltage across the discs to cause them to expand and effect a mechanical elongation axially of the column. The column is mounted within an enclosure having an inlet port and an outlet port with an internal seat in communication with the outlet port, such that a plug secured to the end of the column will engage the seat of the outlet port to close the outlet port in response to the application of voltage is regulated by a conventional electronic timing circuit connected to the column. (AEC)
Microfluidic liquid chromatography system for proteomic applications and biomarker screening.
Lazar, Iulia M; Trisiripisal, Phichet; Sarvaiya, Hetal A
2006-08-01
A microfluidic liquid chromatography (LC) system for proteomic investigations that integrates all the necessary components for stand-alone operation, i.e., pump, valve, separation column, and electrospray interface, is described in this paper. The overall size of the LC device is small enough to enable the integration of two fully functional separation systems on a 3 in. x 1 in. glass microchip. A multichannel architecture that uses electroosmotic pumping principles provides the necessary functionality for eluent propulsion and sample valving. The flow rates generated within these chips are fully consistent with the requirements of nano-LC platforms that are routinely used in proteomic applications. The microfluidic device was evaluated for the analysis of a protein digest obtained from the MCF7 breast cancer cell line. The cytosolic protein extract was processed according to a shotgun protocol, and after tryptic digestion and prefractionation using strong cation exchange chromatography (SCX), selected sample subfractions were analyzed with conventional and microfluidic LC platforms. Using similar experimental conditions, the performance of the microchip LC was comparable to that obtained with benchtop instrumentation, providing an overlap of 75% in proteins that were identified by more than two unique peptides. The microfluidic LC analysis of a protein-rich SCX fraction enabled the confident identification of 77 proteins by using conventional data filtering parameters, of 39 proteins with p < 0.001, and of 5 proteins that are known to be cancer-specific biomarkers, demonstrating thus the potential applicability of these chips for future high-throughput biomarker screening applications.
Moche, Jason A; Cohen, Justin C; Pearlman, Steven J
2013-07-01
The objective of this work was to explore the utility of axial computed tomography (CT) imaging to objectively define a narrow internal nasal valve, and compare those findings with clinical examination and patient complaint. Retrospective review from a single facial plastic surgery center. We reviewed 40 consecutive patients evaluated for either sinusitis or nasal airway obstruction for which a CT scan was obtained at a single radiology institution. Thirty-six complete office records were examined for the presence of clinical internal valve narrowing and complaints of nasal obstruction. In total, 72 internal nasal valves were analyzed using axial plane CT and measurements were compared to clinical findings and presence of airway obstruction. Measured valve areas for clinically normal internal nasal valves averaged 0.47 cm(2) vs 0.28 cm(2) for clinically narrow valves, a decrease of 40.4%. In unobstructed nasal airways the valve area averaged 0.51 cm(2) vs 0.38 cm(2) in obstructed airways, a difference of 25.5%. A radiographically measured valve area of <0.30 cm(2) suggests clinical narrowing with a sensitivity of 71.4%, specificity of 88.9%, positive predictive value of 62.5%, and negative predictive value of 92.3%. Using standard axial CT imaging we describe an objective method of radiographically evaluating the nasal valve, demonstrating strong correlation with physical examination and patient complaint. Additionally, radiographic valve areas can be used to screen for clinically narrow nasal valves with good sensitivity and specificity, providing a novel straightforward method for nasal valve assessment. © 2012 ARS-AAOA, LLC.
Two stroke homogenous charge compression ignition engine with pulsed air supplier
Clarke, John M.
2003-08-05
A two stroke homogenous charge compression ignition engine includes a volume pulsed air supplier, such as a piston driven pump, for efficient scavenging. The usage of a homogenous charge tends to decrease emissions. The use of a volume pulsed air supplier in conjunction with conventional poppet type intake and exhaust valves results in a relatively efficient scavenging mode for the engine. The engine preferably includes features that permit valving event timing, air pulse event timing and injection event timing to be varied relative to engine crankshaft angle. The principle use of the invention lies in improving diesel engines.
NASA Technical Reports Server (NTRS)
Webb, J. A., Jr.; Mehmed, O.; Lorenzo, C. F.
1980-01-01
An airflow valve and its electrohydraulic actuation servosystem are described. The servosystem uses a high-power, single-stage servovalve to obtain a dynamic response beyond that of systems designed with conventional two-stage servovalves. The electrohydraulic servosystem is analyzed and the limitations imposed on system performance by such nonlinearities as signal saturations and power limitations are discussed. Descriptions of the mechanical design concepts and developmental considerations are included. Dynamic data, in the form of sweep-frequency test results, are presented and comparison with analytical results obtained with an analog computer model is made.
Leong, Paul; Le Roux, Pierre-Yves; Callahan, Jason; Siva, Shankar; Hofman, Michael S; Steinfort, Daniel P
2017-09-01
Endobronchial valves (EBVs) are increasingly deployed in the management of severe emphysema. Initial studies focussed on volume reduction as the mechanism, with subsequent improvement in forced expiratory volume in 1 s (FEV 1 ). More recent studies have emphasized importance of perfusion on predicting outcomes, though findings have been inconsistent. Gallium-68 ventilation-perfusion (V/Q) photon emission tomography (PET)/computed tomography (CT) is a novel imaging modality with advantages in spatial resolution, quantitation, and speed over conventional V/Q scintigraphy. We report a pilot case in which V/Q-PET/CT demonstrated discordant findings compared with quantitative CT analysis, and directed left lower lobe EBV placement. The patient experienced a significant improvement in 6-min walk distance (6MWD) without change in spirometry. Post-EBV V/Q-PET/CT demonstrated a marked decrease in unmatched (detrimental) V/Q areas and improvement in overall V/Q matching on post-EBV V/Q-PET/CT. These preliminary novel findings suggest that EBVs improve V/Q matching and may explain the observed functional improvements.
Spin-dependent transport in antiferromagnetic tunnel junctions
NASA Astrophysics Data System (ADS)
Merodio, P.; Kalitsov, A.; Béa, H.; Baltz, V.; Chshiev, M.
2014-09-01
We investigate the behaviour of spin transfer torque (STT) and tunnelling magnetoresistance (TMR) in epitaxial antiferromagnetic-based tunnel junctions using tight binding calculations in the framework of the Keldysh formalism. We find that the STT out-of-plane component exhibits a staggered spatial distribution similar to its in-plane component. This behaviour is specific to the use of a tunnel barrier and significantly differs from the out-of-plane torques reported in previous works using a metallic spacer. Additionally, we show that unlike conventional ferromagnetic-based tunnel junctions, the TMR can increase with applied bias and reach values comparable to typical magnetoresistances found for usual spin valves.
Wottke, Michael; Deutsch, Marcus-André; Krane, Markus; Piazza, Nicolo; Lange, Ruediger; Bleiziffer, Sabine
2015-01-01
Background Due to a considerable rise in bioprosthetic as opposed to mechanical valve implantations, an increase of patients presenting with failing bioprosthetic surgical valves in need of a reoperation is to be expected. Redo surgery may pose a high-risk procedure. Transcatheter aortic valve-in-valve implantation is an innovative, less-invasive treatment alternative for these patients. However, a comprehensive evaluation of the outcome of consecutive patients after a valve-in-valve TAVI [transcatheter aortic valve-in-surgical aortic valve (TAV-in-SAV)] as compared to a standard reoperation [surgical aortic valve redo-operation (SAV-in-SAV)] has not yet been performed. The goal of this study was to compare postoperative outcomes after TAV-in-SAV and SAV-in-SAV in a single center setting. Methods All SAV-in-SAV and TAV-in-SAV patients from January 2001 to October 2014 were retrospectively reviewed. Patients with previous mechanical or transcatheter valves, active endocarditis and concomitant cardiac procedures were excluded. Patient characteristics, preoperative data, post-procedural complications, and 30-day mortality were collected from a designated database. Mean values ± SD were calculated for all continuous variables. Counts and percentages were calculated for categorical variables. The Chi-square and Fisher exact tests were used to compare categorical variables. Continuous variables were compared using the t-test for independent samples. A 2-sided P value <0.05 was considered statistically significant. Results A total of 102 patients fulfilled the inclusion criteria, 50 patients (49%) underwent a transcatheter valve-in-valve procedure, while 52 patients (51%) underwent redo-surgery. Patients in the TAV-in-SAV group were significantly older, had a higher mean logistic EuroSCORE and exhibited a lower mean left ventricular ejection fraction than patients in the SAV-in-SAV group (78.1±6.7 vs. 66.2±13.1, P<0.001; 27.4±18.7 vs. 14.4±10, P<0.001; and 49.8±13.1 vs. 56.7±15.8, P=0.019 respectively). Postoperative pacemaker implantation and chest tube output were higher in the SAV-in-SAV group compared to the TAV-in-SAV group [11 (21%) vs. 3 (6%), P=0.042 and 0.9±1.0 vs. 0.6±0.9, P=0.047, respectively]. There was no significant difference in myocardial infarction, stroke or dialysis postoperatively. Thirty-day mortality was not significantly different between the two groups [TAV-in-SAV2 (4%) vs. SAV-in-SAV0, P=0.238]. Kaplan-Meier (KM) 1-year survival was significantly lower in the TAV-in-SAV group than in the SAV-in-SAV group (83% vs. 96%, P<0.001). Conclusions The present investigation shows that both groups, irrespective of different baseline comorbidities, show very good early clinical outcomes. While redo surgery is still the standard of care, a subgroup of patients may profit from the transcatheter valve-in-valve procedure. PMID:26543594
Tsai, I-Chen; Lin, Yung-Kai; Chang, Yen; Fu, Yun-Ching; Wang, Chung-Chi; Hsieh, Shih-Rong; Wei, Hao-Ji; Tsai, Hung-Wen; Jan, Sheng-Ling; Wang, Kuo-Yang; Chen, Min-Chi; Chen, Clayton Chi-Chang
2009-04-01
The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Björk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a mitral paravalvular leak. The concordance of MDCT for diagnosing and localizing prosthetic valve disorders and the surgical findings was 100%. Except for images impaired by severe beam-hardening artifacts, MDCT provides excellent delineation of prosthetic valve disorders.
Combined PCI and minimally invasive heart valve surgery for high-risk patients.
Umakanthan, Ramanan; Leacche, Marzia; Petracek, Michael R; Zhao, David X; Byrne, John G
2009-12-01
Combined coronary artery valvular heart disease is a major cause of morbidity and mortality in the adult patient population. The standard treatment for such disease has been open heart surgery in which coronary artery bypass grafting (CABG) is performed concurrently with valve surgery using a median sternotomy and cardiopulmonary bypass. With the increasing complexity of patients referred to surgery, some patients may prove to be poor surgical candidates for combined valve and CABG surgery. In certain selected patients who fall into this category, valve surgery and percutaneous coronary intervention (PCI) have been considered a feasible alternative. Conventionally, valve surgery is performed in the cardiac surgical operating room, whereas PCI is carried out in the cardiac catheterization laboratory. Separation of these two procedural suites has presented a logistic limitation because it impedes the concomitant performance of both procedures in one setting. Hence, PCI and valve surgery usually have been performed as a "two-stage" procedure in two different operative suites, with the procedures being separated by hours, days, or weeks. Technologic advancements have made possible the construction of a "hybrid" procedural suite that combines the facilities of a cardiac surgical operating room with those of a cardiac catheterization laboratory. This design has enabled the concept of "one-stage" or "one-stop" PCI and valve surgery, allowing both procedures to be performed in a hybrid suite in one setting, separated by minutes. The advantages of such a method could prove to be multifold by enabling a less invasive surgical approach and improving logistics, patient satisfaction, and outcomes in selected patients.
NASA Astrophysics Data System (ADS)
Nam, Chunghee; Lee, Ki-Su; Cho, B. K.
2005-05-01
We studied the interlayer coupling strength (Hin) and GMR ratio of a spin-valve with the top free layer, separated by a nano-oxide layer (NOL). With the total thickness of the top free layer being fixed at 60Å, the physical properties of the NOL spin-valve were studied with the thickness (tf) of the free layer under the inserted NOL and compared with those of the normal spin-valve with the same thickness as tf. It was found that the spin-valve with NOL has a higher GMR ratio than that of the normal spin-valve at the optimal condition (tf=40Å) after thermal annealing at T =250°C. The NOL spin-valve also shows a lower Hin than that of the optimal normal spin-valve with tf=40Å, which is comparable to that of the normal spin-valve with tf=60Å. This indicates that the enhancement of GMR, while keeping the Hin to be low, can be achieved by inserting a NOL into the top free layer.
Supercritical carbon dioxide-based sterilization of decellularized heart valves
Hennessy, Ryan S.; Jana, Soumen; Tefft, Brandon J.; Helder, Meghana R.; Young, Melissa D.; Hennessy, Rebecca R.; Stoyles, Nicholas J.; Lerman, Amir
2017-01-01
Objective The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Background Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Methods Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Results Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Conclusions Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Summary Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile using histology, microbe culture and electron microscopy assays. The cusp tensile properties of supercritical carbon dioxide treated valves were higher compared to valves treated with other techniques. Superior sterility and integrity was found in the decellularized valves treated with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. PMID:28337488
Aschoff, A; Kremer, P; Benesch, C; Fruh, K; Klank, A; Kunze, S
1995-04-01
When vertical body position is simulated, conventional differential pressure valves show an absolutely unphysiological flow, which is 2-170 times the normal liquor production rate. Although this is compensated in part by the resistance of the silicon tubes, which may produce up to 94% of the resistance of the complete shunt system, a negative intracranial pressure (ICP) of up to 30-44 cmH2O is an unavoidable consequence, which can be followed by subdural hematomas, slit ventricles, and other well-known complications. Modern shunt technology offers programmable, hydrostatic, and "flow-controlled" valves and anti-siphon devices; we have tested 13 different designs from 7 manufacturers (56 specimens), using the "Heidelberg Valve Test Inventory" with 16 subtests. "Programmable" valves reduce, but cannot exclude, unphysiological flow rates: even in the highest position and in combination with a standard catheter typical programmable Medos-Hakim valves allow a flow of 93-232 ml/h, Sophy SU-8-valves 86-168 ml/h with 30 cmH2O. The effect of hydrostatic valves (Hakim-Lumbar, Chhabra) can be inactivated by movements of daily life. The weight of the metal balls in most valves was too low for adequate flow reduction. Antisiphon devices are highly dependent on external, i.e. subcutaneous, pressure which has unpredictable influences on shunt function, and clinically is sometimes followed by shunt insufficiency. Two new Orbis-Sigma valves showed relatively physiological flow rates even when the vertical position (30 cmH2O) was simulated. One showed an insufficient flow (5.7 ml/h), and one was primarily obstructed. These have by far the smallest outlet of all valves. Additionally, the ruby pin tends to stick. Therefore, a high susceptibility to obliterations and blockade is unavoidable. Encouraging results obtained in pediatric patients contrast with disappointing experiences in some German and Swedish hospitals, which suggests that our laboratory findings are confirmed by clinical results. The concept of strict flow limitation seems to be inadaequate for adult patients, who need a relatively high flow during (nocturnal) ICP crises. The problem of shunt overdrainage remains unsolved.
The role of annular dimension and annuloplasty in tricuspid aortic valve repair.
de Kerchove, Laurent; Mastrobuoni, Stefano; Boodhwani, Munir; Astarci, Parla; Rubay, Jean; Poncelet, Alain; Vanoverschelde, Jean-Louis; Noirhomme, Philippe; El Khoury, Gebrine
2016-02-01
Valve sparing reimplantation can improve the durability of bicuspid aortic valve repair compared with subcommissural annuloplasty, especially in patients with a large basal ring. This study analyses the effect of basal ring size and annuloplasty on valve repair in the setting of a tricuspid aortic valve. From 1995 to 2013, 382 patients underwent elective tricuspid aortic valve repair. We included only those undergoing subcommissural annuloplasty, valve sparing reimplantation or no annuloplasty and in whom intraoperative transoesophageal echocardiography images were available for retrospective pre- and post-repair basal ring measurements (n = 323, subcommissural annuloplasty: 146, valve sparing reimplantation: 154, no annuloplasty: 23). In a subgroup of patients with available echocardiographic images, basal ring was retrospectively measured at the latest follow-up or prior to reoperation. subcommissural annuloplasty and valve sparing reimplantation were compared after matching for degree of aortic regurgitation and root size. All three groups differed significantly for most of preoperative characteristics. Hospital mortality was 0.9%. The median follow-up was 4.7 years. At 8 years, overall survival was 80 ± 5%. Freedom from reoperation and freedom from aortic regurgitation >1+ were 92 ± 5% and 71 ± 8%, respectively. In multivariate analysis, predictors of aortic regurgitation >1+ were left ventricular end-diastolic diameter (P = 0.003), cusp repair (P = 0.006), body surface area (P = 0.01) and subcommissural annuloplasty (P = 0.05). In subcommissural annuloplasty, freedom from aortic regurgitation >1+ was lower for patients with basal ring ≥28 mm compared with patients with basal ring <28 mm (P = 0.0001). In valve sparing reimplantation, freedom from aortic regurgitation >1+ was independent of basal ring size (P = 0.38). In matched comparison between subcommissural annuloplasty and valve sparing reimplantation, freedom from aortic regurgitation >1+ was not significantly different (P = 0.06), but in patients with basal ring ≥28 mm, valve sparing reimplantation was superior to subcommissural annuloplasty (P = 0.04). Despite similar intraoperative reduction in basal ring size in subcommissural annuloplasty and valve sparing reimplantation, patients with subcommissural annuloplasty exhibited greater increase in basal ring size during the follow-up compared with the valve sparing reimplantation group (P < 0.001). As with a bicuspid aortic valve, a large basal ring predicts recurrence of aortic regurgitation in patients with tricuspid aortic valve undergoing repair with the subcommissural annuloplasty technique. This recurrence is caused by basal ring dilatation over time after subcommissural annuloplasty. With the valve sparing reimplantation technique, large basal ring did not predict aortic regurgitation recurrence, as prosthetic-based circumferential annuloplasty displayed better stability over time. Stable circumferential annuloplasty is recommended in tricuspid aortic valve repair whenever the basal ring size is ≥28 mm. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conklin, Jim; Szybist, James P
2010-01-01
A concept is presented here that adds two additional strokes to the four-stroke Otto or Diesel cycle that has the potential to increase fuel efficiency of the basic cycle. The engine cycle can be thought of as a 4 stroke Otto or Diesel cycle followed by a 2-stroke heat recovery steam cycle. Early exhaust valve closing during the exhaust stroke coupled with water injection are employed to add an additional power stroke at the end of the conventional four-stroke Otto or Diesel cycle. An ideal thermodynamics model of the exhaust gas compression, water injection at top center, and expansion wasmore » used to investigate this modification that effectively recovers waste heat from both the engine coolant and combustion exhaust gas. Thus, this concept recovers energy from two waste heat sources of current engine designs and converts heat normally discarded to useable power and work. This concept has the potential of a substantial increase in fuel efficiency over existing conventional internal combustion engines, and under appropriate injected water conditions, increase the fuel efficiency without incurring a decrease in power density. By changing the exhaust valve closing angle during the exhaust stroke, the ideal amount of exhaust can be recompressed for the amount of water injected, thereby minimizing the work input and maximizing the mean effective pressure of the steam expansion stroke (MEPsteam). The value of this exhaust valve closing for maximum MEPsteam depends on the limiting conditions of either one bar or the dew point temperature of the expansion gas/moisture mixture when the exhaust valve opens to discard the spent gas mixture in the sixth stroke. The range of MEPsteam calculated for the geometry of a conventional gasoline spark-ignited internal combustion engine and for plausible water injection parameters is from 0.75 to 2.5 bars. Typical combustion mean effective pressures (MEPcombustion) of naturally aspirated gasoline engines are up to 10 bar, thus this concept has the potential to significantly increase the engine efficiency and fuel economy while not resulting in a decrease in power density.« less
Alozie, Anthony; Westphal, Bernd; Kische, Stephan; Kaminski, Alexander; Paranskaya, Liliya; Bozdag-Turan, Ilkay; Ortak, Jasmin; Schubert, Jochen; Steinhoff, Gustav; Ince, Hüseyin
2014-07-01
Percutaneous edge-to-edge devices for non-surgical repair of mitral valve regurgitation are under clinical evaluation in high-risk patients deemed not suitable for conventional surgery. To address guidelines for initial therapy decision, we here report on 13 cases of surgery after failed percutaneous edge-to-edge mitral valve repair or attempted repair, and discuss methodology and prognostic factors for operative outcome in this high-risk situation. Thirteen patients referred to our cardiothoracic unit after failed percutaneous mitral valve repair or attempted repair using the edge-to-edge technique, were treated surgically for mitral valve failure between June 2010 and December 2012. Pathology of mitral valve before and after interventional mitral valve repair (especially prevalent mode of failure) was evaluated and classified for each individual patient by echocardiography and intraoperative direct visualization. Number of implanted edge-to-edge devices were identified. Preoperative risk scores were matched with intraoperative observations and histopathological findings of valve tissue. Postoperative morbidity and mortality were analysed with respect to mitral valve and patient-related data. Three of 10 patients were referred with severe mitral valve regurgitation/stenosis after initially successful percutaneous edge-to-edge therapy or attempted therapy. In 3 patients, ≥ 2 edge-to-edge devices were implanted leading to very tight edge-to-edge leaflet connection and fibrosis. All patients underwent successful surgical mitral valve replacement and concomitant complete cardiac surgery (CABG, aortic or tricuspid valve surgery, ASD closure and pulmonary vein isolation for atrial fibrillation). The likelihood of repair was reduced with respect to multiple edge-to-edge technology. One device could not be harvested surgically because of embolization. One patient died on the second postoperative day due to sepsis with multiple organ failure. The remaining 12 patients were discharged with excellent valve prosthesis function and followed up to 2 years post-surgery. The current long-term survival rate is 77%. Our series demonstrate that highest risk patients can survive mitral valve surgery after failed multiple edge-to-edge interventional mitral valve repair. As long-term results of the MitraClip therapy are pending, we recommend close meshed follow-up of patients treated with the MitraClip device, especially within the first year of the index procedure as delays in salvage management, interventional or surgical, when the index procedure fails may increase morbidity and mortality. © The Author 2013. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Quantification and comparison of the mechanical properties of four human cardiac valves.
Pham, Thuy; Sulejmani, Fatiesa; Shin, Erica; Wang, Di; Sun, Wei
2017-05-01
Although having the same ability to permit unidirectional flow within the heart, the four main valves-the mitral valve (MV), aortic (AV), tricuspid (TV) and pulmonary (PV) valves-experience different loading conditions; thus, they exhibit different structural integrity from one another. Most research on heart valve mechanics have been conducted mainly on MV and AV or an individual valve, but none quantify and compare the mechanical and structural properties among the four valves from the same aged patient population whose death was unrelated to cardiovascular disease. A total of 114 valve leaflet samples were excised from 12 human cadavers whose death was unrelated to cardiovascular disease (70.1±3.7years old). Tissue mechanical and structural properties were characterized by planar biaxial mechanical testing and histological methods. The experimental data were then fitted with a Fung-type constitutive model. The four valves differed substantially in thickness, degree of anisotropy, and stiffness. The leaflets of the left heart (the AV leaflets and the anterior mitral leaflets, AML) were significantly stiffer and less compliant than their counterparts in the right heart. TV leaflets were the most extensible and isotropic, while AML and AV leaflets were the least extensible and the most anisotropic. Age plays a significant role in the reduction of leaflet stiffness and extensibility with nearly straightened collagen fibers observed in the leaflet samples from elderly groups (65years and older). Results from 114 human leaflet samples not only provided a baseline quantification of the mechanical properties of aged human cardiac valves, but also offered a better understanding of the age-dependent differences among the four valves. It is hoped that the experimental data collected and the associated constitutive models in this study can facilitate future studies of valve diseases, treatments and the development of interventional devices. Most research on heart valve mechanics have been conducted mainly on mitral and aortic valves or an individual valve, but none quantify and compare the mechanical and structural properties among the four valves from the same relatively healthy elderly patient population. In this study, the mechanical and microstructural properties of 114 leaflets of aortic, mitral, pulmonary and tricuspid valves from 12 human cadaver hearts were mechanically tested, analyzed and compared. Our results not only provided a baseline quantification of the mechanical properties of aged human valves, but a age range between patients (51-87years) also offers a better understanding of the age-dependent differences among the four valves. It is hoped that the obtained experimental data and associated constitutive parameters can facilitate studies of valve diseases, treatments and the development of interventional devices. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Reul, Ross M.; Ramchandani, Mahesh K.; Reardon, Michael J.
2017-01-01
Surgical aortic valve replacement is the gold standard procedure to treat patients with severe, symptomatic aortic valve stenosis or insufficiency. Bioprosthetic valves are used for surgical aortic valve replacement with a much greater prevalence than mechanical valves. However, bioprosthetic valves may fail over time because of structural valve deterioration; this often requires intervention due to severe bioprosthetic valve stenosis or regurgitation or a combination of both. In select patients, transcatheter aortic valve replacement is an alternative to surgical aortic valve replacement. Transcatheter valve-in-valve (ViV) replacement is performed by implanting a transcatheter heart valve within a failing bioprosthetic valve. The transcatheter ViV operation is a less invasive procedure compared with reoperative surgical aortic valve replacement, but it has been associated with specific complications and requires extensive preoperative work-up and planning by the heart team. Data from experimental studies and analyses of results from clinical procedures have led to strategies to improve outcomes of these procedures. The type, size, and implant position of the transcatheter valve can be optimized for individual patients with knowledge of detailed dimensions of the surgical valve and radiographic and echocardiographic measurements of the patient's anatomy. Understanding the complexities of the ViV procedure can lead surgeons to make choices during the original surgical valve implantation that can make a future ViV operation more technically feasible years before it is required. PMID:29743998
Valve exploiting the principle of a side channel turbine
NASA Astrophysics Data System (ADS)
Jandourek, Pavel; Habán, Vladimír; Pochylý, František; Fic, Miloslav
The article deals with a side channel turbine, which can be used as a suitable substitute for a pressure reducing valve. Reducing valves are a source of hydraulic losses. The aim is to replace them by a side channel turbine. With that in mind, hydraulic losses can be replaced by a production of electrical energy at comparable characteristics of the valve and the turbine. The basis for the design is the loss characteristics of the valve. Thereby creating a kind of turbine valve with speed-controlled flow in dependence of runner revolution.
Lee, Naeun; Ma, Kyoung Tak; Bae, Hyoung Won; Hong, Samin; Seong, Gong Je; Hong, Young Jae; Kim, Chan Yun
2015-04-01
To compare the surgical results of trabeculectomy and Ahmed glaucoma valve implantation after a previous failed trabeculectomy. A retrospective comparative case series review was performed on 31 eye surgeries in 20 patients with primary congenital glaucoma who underwent trabeculectomy or Ahmed glaucoma valve implantation after a previous failed trabeculectomy with mitomycin C. The preoperative mean intraocular pressure was 25.5 mmHg in the trabeculectomy group and 26.9 mmHg in the Ahmed glaucoma valve implantation group (p = 0.73). The 48-month postoperative mean intraocular pressure was 19.6 mmHg in the trabeculectomy group and 20.2 mmHg in the Ahmed glaucoma valve implantation group (p = 0.95). The 12-month trabeculectomy success rate was 69%, compared with 64% for Ahmed glaucoma valve implantation, and the 48-month success rates were 42% and 36% for trabeculectomy and valve implantation, respectively. The success rates following the entire follow-up period were not significantly different between the two groups (p > 0.05 by log rank test). Postoperative complications occurred in 25% of the trabeculectomy-operated eyes and 9% of the Ahmed-implanted eyes (p = 0.38). There was no significant difference in surgical outcome between the trabeculectomy and Ahmed glaucoma valve implantation groups, neither of which had favorable results. However, the trabeculectomy group demonstrated a higher prevalence of adverse complications such as post-operative endophthalmitis.
Giant magneto-spin-Seebeck effect and magnon transfer torques in insulating spin valves
NASA Astrophysics Data System (ADS)
Cheng, Yihong; Chen, Kai; Zhang, Shufeng
2018-01-01
We theoretically study magnon transport in an insulating spin valve (ISV) made of an antiferromagnetic insulator sandwiched between two ferromagnetic insulator (FI) layers. In the conventional metal-based spin valve, the electron spins propagate between two metallic ferromagnetic layers, giving rise to giant magnetoresistance and spin transfer torque. Here, the incoherent magnons in the ISV serve as angular momentum carriers and are responsible for the angular momentum transport between two FI layers across the antiferromagnetic spacer. We predict two transport phenomena in the presence of the temperature gradient: a giant magneto-spin-Seebeck effect in which the output voltage signal is controlled by the relative orientation of the two FI layers and magnon transfer torque that can be used for switching the magnetization of the FI layers with a temperature gradient of the order of 0.1 Kelvin per nanometer.
Value contamination avoidance devices
NASA Technical Reports Server (NTRS)
Endicott, D. L.
1975-01-01
Mechanical redesign methods were used to minimize contamination damage of conventional fluid components and a contamination separator device was developed for long term reusable space vehicles. These were incorporated into an existing 50.8 mm poppet valve and tested for damage tolerance in a full size open loop flow system with gaseous and liquid nitrogen. Cyclic and steady flow conditions were tested with particles of 125 to 420 micrometers aluminum oxide dispersed in the test fluids. Nonflow life tests (100,000 cycles) were made with two valve configurations in gaseous hydrogen. The redesigned valve had an acceptable cycle life and improved tolerance to contamination damage when the primary sealing surfaces were coated with thin coatings of hard plastic (Teflon S and Kynar). Analytical studies and flow testing were completed of four different versions of the separator. overall separation efficiencies in the 55-90% range were measured with these non-optimum configurations.
In Vitro Evaluation of a Novel Hemodynamically Optimized Trileaflet Polymeric Prosthetic Heart Valve
Claiborne, Thomas E.; Sheriff, Jawaad; Kuetting, Maximilian; Steinseifer, Ulrich; Slepian, Marvin J.; Bluestein, Danny
2013-01-01
Calcific aortic valve disease is the most common and life threatening form of valvular heart disease, characterized by stenosis and regurgitation, which is currently treated at the symptomatic end-stages via open-heart surgical replacement of the diseased valve with, typically, either a xenograft tissue valve or a pyrolytic carbon mechanical heart valve. These options offer the clinician a choice between structural valve deterioration and chronic anticoagulant therapy, respectively, effectively replacing one disease with another. Polymeric prosthetic heart valves (PHV) offer the promise of reducing or eliminating these complications, and they may be better suited for the new transcatheter aortic valve replacement (TAVR) procedure, which currently utilizes tissue valves. New evidence indicates that the latter may incur damage during implantation. Polymer PHVs may also be incorporated into pulsatile circulatory support devices such as total artificial heart and ventricular assist devices that currently employ mechanical PHVs. Development of polymer PHVs, however, has been slow due to the lack of sufficiently durable and biocompatible polymers. We have designed a new trileaflet polymer PHV for surgical implantation employing a novel polymer—xSIBS—that offers superior bio-stability and durability. The design of this polymer PHV was optimized for reduced stresses, improved hemodynamic performance, and reduced thrombogenicity using our device thrombogenicity emulation (DTE) methodology, the results of which have been published separately. Here we present our new design, prototype fabrication methods, hydrodynamics performance testing, and platelet activation measurements performed in the optimized valve prototype and compare it to the performance of a gold standard tissue valve. The hydrodynamic performance of the two valves was comparable in all measures, with a certain advantage to our valve during regurgitation. There was no significant difference between the platelet activation rates of our polymer valve and the tissue valve, indicating that similar to the latter, its recipients may not require anticoagulation. This work proves the feasibility of our optimized polymer PHV design and brings polymeric valves closer to clinical viability. PMID:23445066
A new design of groundwater sampling device and its application.
Tsai, Yih-jin; Kuo, Ming-ching T
2005-01-01
Compounds in the atmosphere contaminate samples of groundwater. An inexpensive and simple method for collecting groundwater samples is developed to prevent contamination when the background concentration of contaminants is high. This new design of groundwater sampling device involves a glass sampling bottle with a Teflon-lined valve at each end. A cleaned and dried sampling bottle was connected to a low flow-rate peristaltic pump with Teflon tubing and was filled with water. No headspace volume was remained in the sampling bottle. The sample bottle was then packed in a PVC bag to prevent the target component from infiltrating into the water sample through the valves. In this study, groundwater was sampled at six wells using both the conventional method and the improved method. The analysis of trichlorofluoromethane (CFC-11) concentrations at these six wells indicates that all the groundwater samples obtained by the conventional sampling method were contaminated by CFC-11 from the atmosphere. The improved sampling method greatly eliminated the problems of contamination, preservation and quantitative analysis of natural water.
Modified Lipoprotein-Derived Lipid Particles Accumulate in Human Stenotic Aortic Valves
Lehti, Satu; Käkelä, Reijo; Hörkkö, Sohvi; Kummu, Outi; Helske-Suihko, Satu; Kupari, Markku; Werkkala, Kalervo; Kovanen, Petri T.; Öörni, Katariina
2013-01-01
In aortic stenosis plasma lipoprotein-derived lipids accumulate in aortic valves. Here, we first compared the lipid compositions of stenotic aortic valves and atherosclerotic plaque cores. Both pathological tissues were found to be enriched in cholesteryl linoleate, a marker of extracellularly accumulated lipoproteins. In addition, a large proportion of the phospholipids were found to contain arachidonic acid, the common precursor of a number of proinflammatory lipid mediators. Next, we isolated and characterized extracellular lipid particles from human stenotic and non-stenotic control valves, and compared them to plasma lipoproteins from the same subjects. The extracellular valvular lipid particles were isolated from 15 stenotic and 14 non-stenotic aortic valves. Significantly more apoB-100-containing lipid particles were found in the stenotic than in the non-stenotic valves. The majority of the lipid particles isolated from the non-stenotic valves had sizes (23±6.2 nm in diameter) similar to those of plasma low density lipoprotein (LDL) (22±1.5 nm), while the lipid particles from stenotic valves were not of uniform size, their sizes ranging from 18 to more than 500 nm. The lipid particles showed signs of oxidative modifications, and when compared to isolated plasma LDL particles, the lipid particles isolated from the stenotic valves had a higher sphingomyelin/phosphatidylcholine –ratio, and also higher contents of lysophosphatidylcholine and unesterified cholesterol. The findings of the present study reveal, for the first time, that in stenotic human aortic valves, infiltrated plasma lipoproteins have undergone oxidative and lipolytic modifications, and become fused and aggregated. The generated large lipid particles may contribute to the pathogenesis of human aortic stenosis. PMID:23762432
Thrombocytopenia following implantation of the stentless biological sorin freedom SOLO valve.
Gersak, Borut; Gartner, Urska; Antonic, Miha
2011-07-01
Stentless biological valves have proven advantages in hemodynamic performance and left ventricular function compared to stented biological valves. Following a marked postoperative fall in the platelet count of patients after implantation of the Freedom SOLO valve, the study aim was to confirm clinical observations that this effect was more severe in patients receiving Freedom SOLO valves than in those receiving St. Jude Medical (SJM) mechanical aortic valves. Preoperative and postoperative platelet counts were compared in two groups of patients who underwent aortic valve replacement (AVR) without any concomitant procedures between January and December 2007. Patients received either a Freedom SOLO valve (n = 28) or a SJM mechanical valve (n = 41). Mean values of platelet counts were compared using three multiple linear regression models. Platelet counts were significantly lower in the Freedom SOLO group than in the SJM group from the first postoperative day (POD 1) up to POD 6 (p <0.001). In three patients of the Freedom SOLO group the platelet count fell below 30x10(9)/l, while the lowest level in the SJM group was 75x10(9)/l. Based on multiple linear regression models, the type of valve implanted had a statistically significant influence on postoperative platelet counts on POD 1, POD 3, and POD 5 (p <0.001). Whilst the reason for this phenomenon is unknown, the use of consistent monitoring should prevent severe falls in platelet count from becoming dangerous for the patient. Further studies are required to investigate the phenomenon since, despite a shorter cardiopulmonary bypass time, the fall in platelet count was more profound in the Freedom SOLO group.
Toomarian, Lida; Rikhtegaran, Sahand; Sadighi, Mehrnoosh; Savadi Oskoee, Siavash; Alizadeh Oskoee, Parnian
2007-01-01
Dental handpiece is a source of contamination because it is in constant touch with the oral cavity. Sterilization does not seem to be sufficient to prevent penetration of microorganisms into air and water lines of the unit, because negative pressure developed by valves (which are placed in water outlets) and post shut-off inertial rotation of handpiece result in water and debris being sucked into air and water outlets of dental unit. The aim of this study was to compare dental unit contamination following use of clean head system handpieces and conventional handpieces. Twenty-two dental units in the Department of Pediatric Dentistry in Shahid Beheshti Faculty of Dentistry were used for the purpose of this study. A 1.5×108 cfu/mm3 concentration of Staphylococcus epidermis (SE) was used to contaminate the air and water outlets of dental units. Ten clean head system handpieces and 10 conventional handpieces were used for 30 seconds in the above-mentioned suspension. Microbial samples were collected from the air and water lines. Culturing and colony counting procedures were carried out. Data was analyzed by t-test; a value of p<0.01 was considered significant. Results demonstrated a significantly lower SE contamination in water outlets following the use of clean head system (p<0.01). A lower tendency of clean head system handpieces to transmit SE compared to conventional system makes them a better choice for infection control.
Tissue-Engineered Fibrin-Based Heart Valve with a Tubular Leaflet Design
Weber, Miriam; Heta, Eriona; Moreira, Ricardo; Gesche, Valentine N.; Schermer, Thomas; Frese, Julia
2014-01-01
The general approach in heart valve tissue engineering is to mimic the shape of the native valve in the attempt to recreate the natural haemodynamics. In this article, we report the fabrication of the first tissue-engineered heart valve (TEHV) based on a tubular leaflet design, where the function of the leaflets of semilunar heart valves is performed by a simple tubular construct sutured along a circumferential line at the root and at three single points at the sinotubular junction. The tubular design is a recent development in pericardial (nonviable) bioprostheses, which has attracted interest because of the simplicity of the construction and the reliability of the implantation technique. Here we push the potential of the concept further from the fabrication and material point of view to realize the tube-in-tube valve: an autologous, living HV with remodelling and growing capability, physiological haemocompatibility, simple to construct and fast to implant. We developed two different fabrication/conditioning procedures and produced fibrin-based constructs embedding cells from the ovine umbilical cord artery according to the two different approaches. Tissue formation was confirmed by histology and immunohistology. The design of the tube-in-tube foresees the possibility of using a textile coscaffold (here demonstrated with a warp-knitted mesh) to achieve enhanced mechanical properties in vision of implantation in the aortic position. The tube-in-tube represents an attractive alternative to the conventional design of TEHVs aiming at reproducing the valvular geometry. PMID:23829551
System for detecting operating errors in a variable valve timing engine using pressure sensors
Wiles, Matthew A.; Marriot, Craig D
2013-07-02
A method and control module includes a pressure sensor data comparison module that compares measured pressure volume signal segments to ideal pressure volume segments. A valve actuation hardware remedy module performs a hardware remedy in response to comparing the measured pressure volume signal segments to the ideal pressure volume segments when a valve actuation hardware failure is detected.
Force measuring valve assemblies, systems including such valve assemblies and related methods
DeWall, Kevin George [Pocatello, ID; Garcia, Humberto Enrique [Idaho Falls, ID; McKellar, Michael George [Idaho Falls, ID
2012-04-17
Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.
Simulation of proportional control of hydraulic actuator using digital hydraulic valves
NASA Astrophysics Data System (ADS)
Raghuraman, D. R. S.; Senthil Kumar, S.; Kalaiarasan, G.
2017-11-01
Fluid power systems using oil hydraulics in earth moving and construction equipment have been using proportional and servo control valves for a long time to achieve precise and accurate position control backed by system performance. Such valves are having feedback control in them and exhibit good response, sensitivity and fine control of the actuators. Servo valves and proportional valves are possessing less hysteresis when compared to on-off type valves, but when the servo valve spools get stuck in one position, a high frequency called as jitter is employed to bring the spool back, whereas in on-off type valves it requires lesser technology to retract the spool. Hence on-off type valves are used in a technology known as digital valve technology, which caters to precise control on slow moving loads with fast switching times and with good flow and pressure control mimicking the performance of an equivalent “proportional valve” or “servo valve”.
Valve-sparing aortic root replacement in bicuspid aortic valves: a reasonable option?
Aicher, Diana; Langer, Frank; Kissinger, Anke; Lausberg, Henning; Fries, Roland; Schäfers, Hans-Joachim
2004-11-01
Aortic dilatation occurs in many patients with bicuspid aortic valves. We have added root replacement using the remodeling technique originally designed for tricuspid aortic valves to bicuspid aortic valve repair for treatment of the dilated root. We compared the results of remodeling in bicuspid aortic valves with those in tricuspid aortic valves. From October 1995 through January 2004, 60 patients underwent root remodeling for bicuspid aortic valves (group A), and 130 patients underwent root remodeling for tricuspid aortic valves (group B). Correction of cusp prolapse was more often performed in group A (group A, 50/60; group B, 47/130; P < .0001). Transthoracic echocardiography was performed at 1 week, 6 and 12 months, and every year thereafter. Cumulative follow-up was 527 patient-years (mean, 2.9 +/- 2 years). No patient died in group A. Hospital mortality in group B was 5% (5/100; 95% confidence interval,1.6%-11.3%) after elective operations and 10% (3/30; 95% confidence interval, 2.1%-26.5%) after emergency operations. Mean systolic gradients were identical at 1 year (group A, 4.8 +/- 2.1 mm Hg; group B, 4.0 +/- 2 mm Hg) and 5 years (group A, 4.5 +/- 2.3 mm Hg; group B, 3.9 +/- 2.2 mm Hg). Freedom from aortic regurgitation of grade 2 or higher at 5 years was 96% in group A and 83% in group B ( P = .07), and freedom from reoperation at 5 years was 98% in group A and 98% in group B ( P = .73). Valve-sparing aortic replacement with root remodeling can be applied to aortic dilatation and a regurgitant bicuspid aortic valve. Hemodynamic function and valve stability of a repaired bicuspid aortic valve are comparable with those seen in cases of tricuspid anatomy.
Waziri, Farhad; Lyager Nielsen, Sten; Michael Hasenkam, John
2016-09-01
Tricuspid regurgitation may be a precursor for heart failure, reduced functional capacity, and poor survival. A human compatible experimental model is required to understand the pathophysiology of the tricuspid valve disease as a basis for validating novel tricuspid valve interventions before clinical use. The study aim was to evaluate and compare the tricuspid valve anatomy of porcine and human hearts. The anatomy of the tricuspid valve and the surrounding structures that affect the valve during a cardiac cycle were examined in detail in 100 fresh and 19 formalin-fixed porcine hearts obtained from Danish Landrace pigs (body weight 80 kg). All valvular dimensions were compared with human data acquired from literature sources. No difference was seen in the tricuspid annulus circumference between porcine and human hearts (13.0 ± 1.2 cm versus 13.5 ± 1.5 cm; p = NS), or in valve area (5.7 ± 1.6 cm2 versus 5.6 ± 1.0 cm2; p = NS). The majority of chordae types exhibited a larger chordal length and thickness in human hearts compared to porcine hearts. In both species, the anterior papillary muscle (PM) was larger than other PMs in the right ventricle, but muscle length varied greatly (range: 5.2-40.3 mm) and was significantly different in pigs and in humans (12.2 ± 3.2 mm versus 19.2 mm; p <0.001). The porcine tricuspid valve was determined to be a valid model for preclinical animal studies, despite various anatomic differences being noted between porcine and human hearts.
Hummel, Brian W; Buss, Randall W; DiGiorgi, Paul L; Laviano, Brittany N; Yaeger, Nalani A; Lucas, M Lee; Comas, George M
Single-dose antegrade crystalloid cardioplegia with Custodiol-HTK (histidine-tryptophan-ketoglutarate) has been used for many years. Its safety and efficacy were established in experimental and clinical studies. It is beneficial in complex valve surgery because it provides a long period of myocardial protection with a single dose. Thus, valve procedures (minimally invasive or open) can be performed with limited interruption. The aim of this study is to compare the use of Custodiol-HTK cardioplegia with traditional blood cardioplegia in patients undergoing minimally invasive and open valve surgery. A single-institution, retrospective case-control review was performed on patients who underwent valve surgery in Lee Memorial Health System at either HealthPark Medical Center or Gulf Coast Medical Center from July 1, 2011, through March 7, 2015. A total of 181 valve cases (aortic or mitral) performed using Custodiol-HTK cardioplegia were compared with 181 cases performed with traditional blood cardioplegia. Each group had an equal distribution of minimally invasive and open valve cases. Right chest thoracotomy or partial sternotomy was performed on minimally invasive valve cases. Demographics, perioperative data, clinical outcomes, and financial data were collected and analyzed. Patient outcomes were superior in the Custodiol-HTK cardioplegia group for blood transfusion, stroke, and hospital readmission within 30 days (P < 0.05). No statistical differences were observed in the other outcomes categories. Hospital charges were reduced on average by $3013 per patient when using Custodiol-HTK cardioplegia. Use of Custodiol-HTK cardioplegia is safe and cost-effective when compared with traditional repetitive blood cardioplegia in patients undergoing minimally invasive and open valve surgery.
NASA Astrophysics Data System (ADS)
Jung, Wooseok; Barrett, Matthew; Brooks, Carla; Rivera, Andrew; Birdsell, Dawn N.; Wagner, David M.; Zenhausern, Frederic
2015-12-01
We present a new elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis. The valve functions include metering to capture a designated volume of biological sample into a polymerase chain reaction (PCR) chamber, sealing to preserve the sample during PCR cycling, and transfer of the PCR-products and on-chip formamide post-processing for the analysis of DNA fragments by capillary gel electrophoresis. This new valve differs from prior art polydimethylsiloxane (PDMS) valves in that the valve is not actuated externally by air-pressure or vacuum so that it simplifies a DNA analysis system by eliminating the need for an air-pressure or vacuum source, and off-cartridge solenoid valves, control circuit boards and software. Instead, the new valve is actuated by a thermal cycling peltier assembly integrated within the hardware instrument that tightly comes in contact with a microfluidic cartridge for thermal activation during PCR, so that it spontaneously closes the valve without an additional actuator system. The valve has bumps in the designated locations so that it has a self-alignment that does not require precise alignment of a valve actuator. Moreover, the thickness of the new valve is around 600 μm with an additional bump height of 400 μm so that it is easy to handle and very feasible to fabricate by injection molding compared to other PDMS valves whose thicknesses are around 30-100 μm. The new valve provided over 95% of metering performance in filling the fixed volume of the PCR chamber, preserved over 97% of the sample volume during PCR, and showed very comparable capillary electrophoresis peak heights to the benchtop assay tube controls with very consistent transfer volume of the PCR-product and on-chip formamide. The new valve can perform a core function for integrated nucleic acid analysis by capillary electrophoresis.
Hermetic compressor and block expansion valve in refrigeration performance
NASA Astrophysics Data System (ADS)
Santoso, Budi; Susilo, Didik Djoko; Tjahjana, D. D. D. P.
2016-03-01
Vehicle cabin in tropical countries requires the cooling during the day for comfort of passengers. Air conditioning machine is commonly driven by an internal combustion engine having a great power, which the conventional compressor is connected to crank shaft. The stage of research done is driving the hermetic compressor with an electric motor, and using block expansion valve. The HFC-134a was used as refrigerant working. The primary parameters observed during the experiment are pressure, temperature, and power consumption for different cooling capacities. The results show that the highest coefficient of performance (COP) and the electric power of system are 6.3 and 638 Watt, respectively.
Highly Efficient Spin-Current Operation in a Cu Nano-Ring
NASA Astrophysics Data System (ADS)
Murphy, Benedict A.; Vick, Andrew J.; Samiepour, Marjan; Hirohata, Atsufumi
2016-11-01
An all-metal lateral spin-valve structure has been fabricated with a medial Copper nano-ring to split the diffusive spin-current path. We have demonstrated significant modulation of the non-local signal by the application of a magnetic field gradient across the nano-ring, which is up to 30% more efficient than the conventional Hanle configuration at room temperature. This was achieved by passing a dc current through a current-carrying bar to provide a locally induced Ampère field. We have shown that in this manner a lateral spin-valve gains an additional functionality in the form of three-terminal gate operation for future spintronic logic.
Microbial Check Valve for Shuttle
NASA Technical Reports Server (NTRS)
Colombo, G. V.; Putnam, D. F.; Sauer, R. L.
1978-01-01
The Microbial Check Valve (MCV) is a device developed for the Space Shuttle that prevents the transfer of viable microorganisms within water systems. The device is essentially a bed of resin material, impregnated with iodine, that kills microorganisms on contact. It prevents the cross-contamination of microorganisms from a nonpotable system into the potable water system when these systems are interconnected. In this regard, the function of the device is similar to that of the 'air gap' found in conventional one-gravity systems. Basic design data are presented including pressure drop, scaling factors, sizing criteria, and the results of challenging the device with suspensions of seven microorganisms including aerobes, anaerobes and spore formers.
Bioprosthetic Aortic Valve Durability: A Meta-Regression of Published Studies.
Wang, Mansen; Furnary, Anthony P; Li, Hsin-Fang; Grunkemeier, Gary L
2017-09-01
To compare structural valve deterioration (SVD) among bioprosthetic aortic valve types, a PubMed search found 54 papers containing SVD-free curves extending to at least 10 years. The curves were digitized and fit to Weibull distributions, and the mean times to valve failure (MTTF) were calculated. Twelve valve models were collapsed into four valve types: Medtronic (Medtronic, Minneapolis, MN) and Edwards (Edwards Lifesciences, Irvine, CA) porcine; and Sorin (Sorin Group [now LivaNova], London, United Kingdom) and Edwards pericardial. Meta-regression found MTTF was associated with the patient's age, publication year, SVD definition, and valve type. Sorin pericardial valves had significantly lower risk-adjusted MTTF (higher SVD risk), and there were no significant differences in MTTF among the other three valve types. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Heart valves from polyester fibers: a preliminary 6-month in vivo study.
Vaesken, Antoine; Pelle, Anne; Pavon-Djavid, Graciela; Rancic, Jeanne; Chakfe, Nabil; Heim, Frederic
2018-06-27
Transcatheter aortic valve implantation (TAVI) has become a popular alternative technique to surgical valve replacement for critical patients. Biological valve tissue has been used in TAVI procedures for over a decade, with over 150,000 implantations to date. However, with only 6 years of follow up, little is known about the long-term durability of biological tissue. Moreover, the high cost of tissue harvesting and chemical treatment procedures favor the development of alternative synthetic valve leaflet materials. In that context, textile polyester [polyethylene terephthalate (PET)] could be considered as an interesting candidate to replace the biological valve leaflets in TAVI procedures. However, no result is available in the literature about the behavior of textile once in contact with biological tissue in the valve position. The interaction of synthetic textile material with living tissues should be comparable to biological tissue. The purpose of this preliminary work is to compare the in vivo performances of various woven textile PET valves over a 6-month period in order to identify favorable textile construction features. In vivo results indicate that fibrosis as well as calcium deposit can be limited with an appropriate material design.
Weitsman, Tatyana; Weisz, Giora; Farkash, Rivka; Klutstein, Marc; Butnaru, Adi; Rosenmann, David; Hasin, Tal
2017-11-01
Pulmonary hypertension has many causes. While it is conventionally thought that the most prevalent is left heart disease, little information about its proportion, causes, and implications on outcome is available. Between 1993 and 2015, 12,115 of 66,949 (18%) first adult transthoracic echocardiograms were found to have tricuspid incompetence gradient ≥40 mm Hg, a pulmonary hypertension surrogate. Left heart disease was identified in 8306 (69%) and included valve malfunction in 4115 (49%), left ventricular systolic dysfunction in 2557 (31%), and diastolic dysfunction in 1776 (21%). Patients with left heart disease, as compared with those without left heart disease, were of similar age, fewer were females (50% vs 63% P <.0001), and they had higher tricuspid incompetence gradient (median 48 mm Hg [interquartile range 43, 55] vs 46 mm Hg [42, 54] P <.0001). In reviewing trends over 20 years, the relative proportions of systolic dysfunction decreased and diastolic dysfunction increased (P for trend <.001), while valve malfunction remained the most prevalent cause of pulmonary hypertension with left heart disease. Independent predictors of mortality were age (hazard ratio [HR] 1.05; 95% CI, 1.04-1.05; P <.0001), tricuspid incompetence gradient (HR 1.02; 95% CI, 1.01-1.02, P <.0001 per mm Hg increase), and female sex (HR 0.87; 95% CI, 0.83-0.91, P <.0001). Overall, left heart disease was not an independent risk factor for mortality (HR 1.04; 95% CI, 0.99-1.09; P = .110), but patients with left ventricular systolic dysfunction and with combined systolic dysfunction and valve malfunction had increased mortality compared with patients with pulmonary hypertension but without left heart disease (HR 1.30; 95% CI, 1.20-1.42 and HR 1.44; 95% CI, 1.33-1.55, respectively; P <.0001 for both). Pulmonary hypertension was found to be associated with left heart disease in 69% of patients. Among these patients, valve malfunction and diastolic dysfunction emerged as prominent causes. Left ventricular dysfunction carries additional risk to patients with pulmonary hypertension. Copyright © 2017 Elsevier Inc. All rights reserved.
Yazdani, Shahin; Mahboobipour, Hassan; Pakravan, Mohammad; Doozandeh, Azadeh; Ghahari, Elham
2016-05-01
To determine whether adjunctive mitomycin C (MMC) or amniotic membrane transplantation (AMT) improve the outcomes of Ahmed glaucoma valve (AGV) implantation. This double-blind, stratified, 3-armed randomized clinical trial includes 75 eyes of 75 patients aged 7 to 75 years with refractory glaucoma. Eligible subjects underwent stratified block randomization; eyes were first stratified to surgery in the superior or inferior quadrants based on feasibility; in each subgroup, eyes were randomly assigned to the study arms using random blocks: conventional AGV implantation (group A, 25 eyes), AGV with MMC (group B, 25 eyes), and AGV with AMT (group C, 25 eyes). The 3 study groups were comparable regarding baseline characteristics and mean follow-up (P=0.288). A total of 68 patients including 23 eyes in group A, 25 eyes in group B, and 20 eyes group C completed the follow-up period and were analyzed. Intraocular pressure was lower in the MMC group only 3 weeks postoperatively (P=0.04) but comparable at other time intervals. Overall success rate was comparable in the 3 groups at 12 months (P=0.217). The number of eyes requiring medications (P=0.30), time to initiation of medications (P=0.13), and number of medications (P=0.22) were comparable. Hypertensive phase was slightly but insignificantly more common with standard surgery (82%) as compared with MMC-augmented (60%) and AMT-augmented (70%) procedures (P=0.23). Complications were comparable over 1 year (P=0.28). Although adjunctive MMC and AMT were safe during AGV implantation, they did not influence success rates or intraocular pressure outcomes. Complications, including hypertensive phase, were also comparable.
Recellularization of decellularized heart valves: Progress toward the tissue-engineered heart valve
VeDepo, Mitchell C; Detamore, Michael S; Hopkins, Richard A; Converse, Gabriel L
2017-01-01
The tissue-engineered heart valve portends a new era in the field of valve replacement. Decellularized heart valves are of great interest as a scaffold for the tissue-engineered heart valve due to their naturally bioactive composition, clinical relevance as a stand-alone implant, and partial recellularization in vivo. However, a significant challenge remains in realizing the tissue-engineered heart valve: assuring consistent recellularization of the entire valve leaflets by phenotypically appropriate cells. Many creative strategies have pursued complete biological valve recellularization; however, identifying the optimal recellularization method, including in situ or in vitro recellularization and chemical and/or mechanical conditioning, has proven difficult. Furthermore, while many studies have focused on individual parameters for increasing valve interstitial recellularization, a general understanding of the interacting dynamics is likely necessary to achieve success. Therefore, the purpose of this review is to explore and compare the various processing strategies used for the decellularization and subsequent recellularization of tissue-engineered heart valves. PMID:28890780
Alozie, Anthony; Paranskaya, Liliya; Westphal, Bernd; Kaminski, Alexander; Steinhoff, Gustav; Sherif, Mohammad; Ince, Hüseyin; Öner, Alper
2017-12-01
Surgical mitral valve repair is the gold standard for treatment of mitral regurgitation. Recently, the transcatheter treatment of mitral regurgitation with the MitraClip ® device (Abbot Vascular Structural Heart, Menlo Park, CA) has demonstrated promising results in treating patients not amenable for surgical correction of mitral valve regurgitation. Most patients reported in the literature requiring surgical bailout after MitraClip treatment presented with residual or recurrent mitral valve regurgitation. Mitral valve stenosis after MitraClip treatment has been rarely reported. From February 2010 to December 2014, four patients out of 165 patients who underwent MitraClip therapy developed symptomatic mitral valve stenosis (2.4%) and needed surgical correction. Data of the four patients were reviewed retrospectively. Follow-up data were obtained from each patient's general practitioner/cardiologist by phone calls and facsimile and were complete in all patients. All four patients were treated with ≥ 2 MitraClip (MC) devices during their initial presentation. All four patients underwent MV replacement with a tissue valve. The postoperative course was uneventful and there was no 30-day mortality. At 6-month follow-up, all patients were alive and in NYHA class I-III. Placement of multiple clip devices may lead to slightly elevated transmitral gradients. This may not necessarily interpret into symptomatic mitral stenosis. However, in some cases this is possible. Caution should be exercised at this phase of the learning curve of the percutaneous MC treatment, especially in use of multiple MC devices. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Air flow through poppet valves
NASA Technical Reports Server (NTRS)
Lewis, G W; Nutting, E M
1920-01-01
Report discusses the comparative continuous flow characteristics of single and double poppet valves. The experimental data presented affords a direct comparison of valves, single and in pairs of different sizes, tested in a cylinder designed in accordance with current practice in aviation engines.
Lee, Naeun; Ma, Kyoung Tak; Bae, Hyoung Won; Hong, Samin; Seong, Gong Je; Hong, Young Jae
2015-01-01
Purpose To compare the surgical results of trabeculectomy and Ahmed glaucoma valve implantation after a previous failed trabeculectomy. Methods A retrospective comparative case series review was performed on 31 eye surgeries in 20 patients with primary congenital glaucoma who underwent trabeculectomy or Ahmed glaucoma valve implantation after a previous failed trabeculectomy with mitomycin C. Results The preoperative mean intraocular pressure was 25.5 mmHg in the trabeculectomy group and 26.9 mmHg in the Ahmed glaucoma valve implantation group (p = 0.73). The 48-month postoperative mean intraocular pressure was 19.6 mmHg in the trabeculectomy group and 20.2 mmHg in the Ahmed glaucoma valve implantation group (p = 0.95). The 12-month trabeculectomy success rate was 69%, compared with 64% for Ahmed glaucoma valve implantation, and the 48-month success rates were 42% and 36% for trabeculectomy and valve implantation, respectively. The success rates following the entire follow-up period were not significantly different between the two groups (p > 0.05 by log rank test). Postoperative complications occurred in 25% of the trabeculectomy-operated eyes and 9% of the Ahmed-implanted eyes (p = 0.38). Conclusions There was no significant difference in surgical outcome between the trabeculectomy and Ahmed glaucoma valve implantation groups, neither of which had favorable results. However, the trabeculectomy group demonstrated a higher prevalence of adverse complications such as post-operative endophthalmitis. PMID:25829827
Water hammer caused by closure of turbine safety spherical valves
NASA Astrophysics Data System (ADS)
Karadžić, U.; Bergant, A.; Vukoslavčević, P.
2010-08-01
This paper investigates water hammer effects caused by closure of spherical valves against the discharge. During the first phase of modernisation of Perućica high-head hydropower plant (HPP), Montenegro, safety spherical valves (inlet turbine valves) have been refurbished on the first two Pelton turbine units. The valve closure is controlled by the valve actuator (hydraulic servomotor). Because the torque acting on the valve body is dependent on flow conditions the valve closing time may vary significantly for different flow velocities (passive valve). For the passive valve the torques acting on the valve body should be considered in the valve model. The valve closing time results from numerical simulation. On the contrary, for the active valve the valve closing time is assumed prior to simulation. The spherical valve boundary condition is incorporated into the method of characteristics (MOC) algorithm. The staggered (diamond) grid in applying the MOC is used in this paper. The passive valve boundary condition is described by the water hammer equations, the valve equation that relates discharge to pressure head drop and the dynamic equation of the valve body motion (torque equation). The active valve boundary condition is described by the first two equations, respectively. Standard quasi-steady friction model is used for estimating friction losses in plant's tunnel and penstocks. Numerical results using both the active and the passive spherical valve models are compared with results of measurements. It has been found that the influence of flow conditions on the spherical valve closing time is minor for the cases considered. Computed and measured results agree reasonably well.
Xuan, Yue; Wang, Zhongjie; Liu, Raymond; Haraldsson, Henrik; Hope, Michael D; Saloner, David A; Guccione, Julius M; Ge, Liang; Tseng, Elaine
2018-03-08
Guidelines for repair of bicuspid aortic valve-associated ascending thoracic aortic aneurysms have been changing, most recently to the same criteria as tricuspid aortic valve-ascending thoracic aortic aneurysms. Rupture/dissection occurs when wall stress exceeds wall strength. Recent studies suggest similar strength of bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms; thus, comparative wall stress may better predict dissection in bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms. Our aim was to determine whether bicuspid aortic valve-ascending thoracic aortic aneurysms had higher wall stresses than their tricuspid aortic valve counterparts. Patients with bicuspid aortic valve- and tricuspid aortic valve-ascending thoracic aortic aneurysms (bicuspid aortic valve = 17, tricuspid aortic valve = 19) greater than 4.5 cm underwent electrocardiogram-gated computed tomography angiography. Patient-specific 3-dimensional geometry was reconstructed and loaded to systemic pressure after accounting for prestress geometry. Finite element analyses were performed using the LS-DYNA solver (LSTC Inc, Livermore, Calif) with user-defined fiber-embedded material model to determine ascending thoracic aortic aneurysm wall stress. Bicuspid aortic valve-ascending thoracic aortic aneurysms 99th-percentile longitudinal stresses were 280 kPa versus 242 kPa (P = .028) for tricuspid aortic valve-ascending thoracic aortic aneurysms in systole. These stresses did not correlate to diameter for bicuspid aortic valve-ascending thoracic aortic aneurysms (r = -0.004) but had better correlation to tricuspid aortic valve-ascending thoracic aortic aneurysms diameter (r = 0.677). Longitudinal stresses on sinotubular junction were significantly higher in bicuspid aortic valve-ascending thoracic aortic aneurysms than in tricuspid aortic valve-ascending thoracic aortic aneurysms (405 vs 329 kPa, P = .023). Bicuspid aortic valve-ascending thoracic aortic aneurysm 99th-percentile circumferential stresses were 548 kPa versus 462 kPa (P = .033) for tricuspid aortic valve-ascending thoracic aortic aneurysms, which also did not correlate to bicuspid aortic valve-ascending thoracic aortic aneurysm diameter (r = 0.007). Circumferential and longitudinal stresses were greater in bicuspid aortic valve- than tricuspid aortic valve-ascending thoracic aortic aneurysms and were more pronounced in the sinotubular junction. Peak wall stress did not correlate with bicuspid aortic valve-ascending thoracic aortic aneurysm diameter, suggesting diameter alone in this population may be a poor predictor of dissection risk. Our results highlight the need for patient-specific aneurysm wall stress analysis for accurate dissection risk prediction. Copyright © 2018 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
AB0 blood types: impact on development of prosthetic mechanical valve thrombosis
Astarcıoğlu, Mehmet Ali; Kalçık, Macit; Yesin, Mahmut; Gürsoy, Mustafa Ozan; Şen, Taner; Karakoyun, Süleyman; Gündüz, Sabahattin; Özkan, Mehmet
2016-01-01
Objective: The non-O alleles of the ABO genotype have been associated with an increased risk of thrombosis. We aimed to assess the association between blood group status and prosthetic valve thrombosis. Methods: The association between AB0 blood group status and prosthetic valve thrombosis was assessed in this retrospective study. Transesophageal echocardiography was performed in 149 patients with a diagnosis of prosthetic valve thrombosis and in 192 control subjects. Results: Non-0 blood group type (p<0.001), presence of NYHA class III-IV status (p<0.001), and central nervous system (p<0.001) and non-central nervous system (p<0.001) emboli were significantly more prevalent in prosthetic valve thrombosis patients than in the control subjects. The incidence of ineffective anticoagulation was higher in patients with prosthetic valve thrombosis than in controls (p<0.001), as was the presence of moderate to severe left atrial spontaneous echo contrast (p<0.001). The non-0 blood prosthetic valve thrombosis subgroup had a higher incidence of obstructive thrombi and central nervous system thrombotic events than having 0 blood prosthetic valve thrombosis subgroup. Non-0 blood group, ineffective anticoagulation, left atrial spontaneous echo contrast, and a poor NYHA functional capacity were identified to be the predictors of prosthetic valve thrombosis. Conclusion: Our data demonstrate that patients with non-0 compared with 0 blood groups have higher incidence of prosthetic valve thrombosis and central nervous system embolism and similar rates of non-central nervous system embolism at presentation compared with 0 blood group type. Thus, non-O blood group may be a risk factor that may be prone to the development of prosthetic valve thrombosis in patients with prosthetic heart valves. PMID:27488753
Koos, Ralf; Brandenburg, Vincent; Mahnken, Andreas Horst; Schneider, Rebekka; Dohmen, Guido; Autschbach, Rüdiger; Marx, Nikolaus; Kramann, Rafael
2013-05-01
Sclerostin is a key negative regulator of bone formation. It was hypothesized that sclerostin might also play a potential role in the development of aortic valve calcification (AVC). The study aim was to evaluate serum sclerostin levels in patients with different degrees of AVC compared to a healthy control group, and to investigate local sclerostin expression in explanted calcified and non-calcified aortic valves. A prospective cross-sectional study was performed in 115 patients (mean age 74 +/- 7 years) with echocardiographically proven AVC. Sclerostin serum levels were measured using ELISA and compared to values obtained from a healthy control population. For quantification of AVC, all patients of the study cohort underwent non-contrast-enhanced dual-source computed tomography (DSCT). Immunohistochemistry (IHC) staining for sclerostin and mRNA sclerostin expression was analyzed in 10 calcified aortic valves and 10 non-calcified age-matched control valves. Patients with AVC showed significantly higher sclerostin serum levels as compared to healthy controls (0.94 +/- 0.45 versus 0.58 +/- 0.26 ng/ml, p < 0.001). A significant correlation between sclerostin serum levels and Agatston AVC scores as assessed by DSCT was observed (r = 0.62, p < 0.001) in the study cohort. IHC revealed positive sclerostin staining in nine calcified valves, in contrast to negative staining for sclerostin in all non-calcified valves. Quantitative real-time PCR confirmed the increased sclerostin expression on mRNA level, with a significant up-regulation of sclerostin mRNA (fold change 150 +/- 52, p < 0.001) expression being shown in calcified aortic valves compared to non-calcified control valves. Co-staining experiments revealed that sclerostin-expressing cells co-express the major osteogenic transcription factor Runx2 and the extracellular matrix protein osteocalcin. Patients with AVC showed increased sclerostin serum levels compared to a healthy reference population, and it was revealed that the severity of AVC may be linked to increased sclerostin serum levels. Moreover, the PCR and staining data demonstrated an increased sclerostin expression in parallel to prototypic markers of osteogenic transdifferentiation, indicating a role of sclerostin in the valvular calcification process.
Glaser, Natalie; Jackson, Veronica; Franco-Cereceda, Anders; Sartipy, Ulrik
2018-05-17
Bovine and porcine bioprostheses are commonly used for surgical aortic valve replacement. It is unknown if the long-term survival differs between the two valve types.We performed a systematic review and meta-analysis to compare survival in patients who underwent aortic valve replacement and received a bovine or a porcine prosthesis. We performed a systematic search of Medline, Embase, Web of Science, and the Cochrane Library. Cohort studies that compared survival between patients who underwent aortic valve replacement and received either a bovine or a porcine bioprosthesis and that reported overall long-term survival with hazard ratio (HR) and 95% confidence interval (CI) were included. Two authors independently reviewed articles considered for inclusion, extracted the information from each study, and performed the quality assessment. We performed a meta-analysis using a random effects model to calculate the pooled HR (95% CI) for all-cause mortality. We did sensitivity analyses to assess the robustness of our findings. Seven studies published between 2010 and 2015 were included, and the combined study population was 49,190 patients. Of these, 32,235 (66%) received a bovine, and 16,955 (34%) received a porcine bioprosthesis. There was no significant difference in all-cause mortality between patients who received a bovine compared with a porcine bioprosthesis (pooled HR 1.00, 95% CI: 0.92-1.09). Heterogeneity between studies was moderate (55.8%, p = 0.04). This systematic review and meta-analysis suggest no difference in survival between patients who received a bovine versus a porcine bioprosthesis after aortic valve replacement. Our study provides valuable evidence for the continuing use of both bovine and porcine bioprosthetic valves for surgical aortic valve replacement. Georg Thieme Verlag KG Stuttgart · New York.
Suh, Young Joo; Kim, Young Jin; Kim, Jin Young; Chang, Suyon; Im, Dong Jin; Hong, Yoo Jin; Choi, Byoung Wook
2017-11-01
We aimed to determine the effect of a whole-heart motion-correction algorithm (new-generation snapshot freeze, NG SSF) on the image quality of cardiac computed tomography (CT) images in patients with mechanical valve prostheses compared to standard images without motion correction and to compare the diagnostic accuracy of NG SSF and standard CT image sets for the detection of prosthetic valve abnormalities. A total of 20 patients with 32 mechanical valves who underwent wide-coverage detector cardiac CT with single-heartbeat acquisition were included. The CT image quality for subvalvular (below the prosthesis) and valvular regions (valve leaflets) of mechanical valves was assessed by two observers on a four-point scale (1 = poor, 2 = fair, 3 = good, and 4 = excellent). Paired t-tests or Wilcoxon signed rank tests were used to compare image quality scores and the number of diagnostic phases (image quality score≥3) between the standard image sets and NG SSF image sets. Diagnostic performance for detection of prosthetic valve abnormalities was compared between two image sets with the final diagnosis set by re-operation or clinical findings as the standard reference. NG SSF image sets had better image quality scores than standard image sets for both valvular and subvalvular regions (P < 0.05 for both). The number of phases that were of diagnostic image quality per patient was significantly greater in the NG SSF image set than standard image set for both valvular and subvalvular regions (P < 0.0001). Diagnostic performance of NG SSF image sets for the detection of prosthetic abnormalities (20 pannus and two paravalvular leaks) was greater than that of standard image sets (P < 0.05). Application of NG SSF can improve CT image quality and diagnostic accuracy in patients with mechanical valves compared to standard images. Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Suchorska, B; Kunz, M; Schniepp, R; Jahn, K; Goetz, C; Tonn, J C; Peraud, A
2015-04-01
In idiopathic normal pressure hydrocephalus (NPH) ventriculoperitoneal (VP) shunt insertion is the method of choice to improve cardinal symptoms such as gait disturbance, urge incontinence and/or dementia. With reduced compliance, the brain of the elderly is prone for overdrainage complications. This was especially true with the use of differential pressure valve implantation. The present study compares clinical outcome and complication rates after VP shunt insertion with differential pressure valves in the early years and gravitational valves since 2005. The authors reviewed patients treated at our institution for NPH since 1995. Differential pressure valves were solely used in the initial years, while the treatment regimen changed to gravitational valves in 2005. Clinical improvement/surgical success rates as well as complications were compared between the two groups. Eighty-nine patients were enrolled for the present study. Mean age at the time of surgery was 73.5 ± 6.3 years. Male patients predominated with 73, compared with 16 female patients. Median follow-up time was 28 ± 26 months. Date of last follow-up was 1st October 2013. Forty-nine patients received a gravitational valve, while 40 were treated with differential pressure valves. In the gravitational group a significant improvement was observed after shunt insertion for gait disorder, cognitive impairment and urge incontinence (p < 0.0001, resp. p = 0.004), while a significant change in the differential pressure group was only seen for gait disorder (p = 0.03) but not for cognition or urinary incontinency (p > 0.05). The risk of hygroma as a sign of shunt overdrainage requiring surgical intervention was significantly higher in the differential pressure group (5 versus 0 in the gravitational group). Patients with NPH treated with gravitational valves in the present cohort showed a more profound improvement in their initial symptoms, including gait disorder, cognitive impairment and urinary incontinency without the risk of overdrainage complications requiring surgical intervention when compared with patients who received differential pressure valves in previous years.
Advanced diesel engine component development program, tasks 4-14
NASA Astrophysics Data System (ADS)
Kaushal, Tony S.; Weber, Karen E.
1994-11-01
This report summarizes the Advanced Diesel Engine Component Development (ADECD) Program to develop and demonstrate critical technology needed to advance the heavy-duty low heat rejection engine concept. Major development activities reported are the design, analysis, and fabrication of monolithic ceramic components; vapor phase and solid film lubrication; electrohydraulic valve actuation; and high pressure common rail injection. An advanced single cylinder test bed was fabricated as a laboratory tool in studying these advanced technologies. This test bed simulates the reciprocator for a system having no cooling system, turbo compounding, Rankine bottoming cycle, common rail injection, and variable valve actuation to achieve fuel consumption of 160 g/kW-hr (.26 lb/hp-hr). The advanced concepts were successfully integrated into the test engine. All ceramic components met their functional and reliability requirements. The firedeck, cast-in-place ports, valves, valve guides, piston cap, and piston ring were made from silicon nitride. Breakthroughs required to implement a 'ceramic' engine included the fabrication of air-gap cylinder heads, elimination of compression gaskets, machining of ceramic valve seats within the ceramic firedeck, fabrication of cast-in-place ceramic port liners, implementation of vapor phase lubrication, and elimination of the engine coolant system. Silicon nitride valves were successfully developed to meet several production abuse test requirements and incorporated into the test bed with a ceramic valve guide and solid film lubrication. The ADECD cylinder head features ceramic port shields to increase insulation and exhaust energy recovery. The combustion chamber includes a ceramic firedeck and piston cap. The tribological challenge posed by top ring reversal temperatures of 550 C was met through the development of vapor phase lubrication using tricresyl phosphate at the ring-liner interface. A solenoid-controlled, variable valve actuation system that eliminated the conventional camshaft was demonstrated on the test bed. High pressure fuel injection via a common rail system was also developed to reduce particulate emissions.
Advanced diesel engine component development program, tasks 4-14
NASA Technical Reports Server (NTRS)
Kaushal, Tony S.; Weber, Karen E.
1994-01-01
This report summarizes the Advanced Diesel Engine Component Development (ADECD) Program to develop and demonstrate critical technology needed to advance the heavy-duty low heat rejection engine concept. Major development activities reported are the design, analysis, and fabrication of monolithic ceramic components; vapor phase and solid film lubrication; electrohydraulic valve actuation; and high pressure common rail injection. An advanced single cylinder test bed was fabricated as a laboratory tool in studying these advanced technologies. This test bed simulates the reciprocator for a system having no cooling system, turbo compounding, Rankine bottoming cycle, common rail injection, and variable valve actuation to achieve fuel consumption of 160 g/kW-hr (.26 lb/hp-hr). The advanced concepts were successfully integrated into the test engine. All ceramic components met their functional and reliability requirements. The firedeck, cast-in-place ports, valves, valve guides, piston cap, and piston ring were made from silicon nitride. Breakthroughs required to implement a 'ceramic' engine included the fabrication of air-gap cylinder heads, elimination of compression gaskets, machining of ceramic valve seats within the ceramic firedeck, fabrication of cast-in-place ceramic port liners, implementation of vapor phase lubrication, and elimination of the engine coolant system. Silicon nitride valves were successfully developed to meet several production abuse test requirements and incorporated into the test bed with a ceramic valve guide and solid film lubrication. The ADECD cylinder head features ceramic port shields to increase insulation and exhaust energy recovery. The combustion chamber includes a ceramic firedeck and piston cap. The tribological challenge posed by top ring reversal temperatures of 550 C was met through the development of vapor phase lubrication using tricresyl phosphate at the ring-liner interface. A solenoid-controlled, variable valve actuation system that eliminated the conventional camshaft was demonstrated on the test bed. High pressure fuel injection via a common rail system was also developed to reduce particulate emissions.
Dual-Use Partnership Addresses Performance Problems with "Y" Pattern Control Valves
NASA Technical Reports Server (NTRS)
Bailey, John W.
2004-01-01
A Dual-Use Cooperative Agreement between the Propulsion Test Directorate (PTD) at Stennis Space Center (SSC) and Oceaneering Reflange, Inc. of Houston, TX has produced an improved 'Y' pattern split-body control valve for use in the propulsion test facilities at Stennis Space Center. The split-body, or clamped bonnet technology, provides for a 'cleaner' valve design featuring enhanced performance and increased flow capacity with extended life expectancy. Other points addressed by the partnership include size, weight and costs. Overall size and weight of each valve will be reduced by 50% compared to valves currently in use at SSC. An initial procurement of two 10 inch valves will result in an overall cost reduction of 15% or approximately $50,000 per valve.
Recent progress in heart valve surgery: innovation or evolution?
Lausberg, H; Schäfers, H J
2004-08-01
Although heart valve surgery continues to evolve in a dynamic fashion, there is still no optimal solution for all patients. Minimally invasive surgery currently receives considerable attention but its value still needs to be determined. Progress has been made in valve repair, which now allows reconstruction in most patients with mitral valve disease. Reconstruction of the aortic valve is now also possible with results that are now comparable to those of mitral repair. In the future a wider application of repair procedures and further improvements of biologic valves can be anticipated not only to influence long-term results, but also the decision making process for conservative or surgical treatment.
Visser, Lance C; Scansen, Brian A; Schober, Karsten E
2013-06-01
A coronary artery anomaly characterized by the presence of a single left coronary ostium with absence of the right coronary ostium and an anomalous prepulmonic right coronary artery course was observed in two dogs with concurrent congenital pulmonary valve stenosis. This unique coronary artery anatomy is similar to the previously described single right coronary ostium with anomalous prepulmonic left coronary artery, the so-called type R2A anomaly, in that an anomalous coronary artery encircles the pulmonary valve annulus. Both dogs of this report, a boxer and an English bulldog, were of breeds known to be at risk for the type R2A anomaly. As such, veterinarians should be aware that the echocardiographic presence of a left coronary ostium in a dog with pulmonary valve stenosis does not exclude the possibility of a prepulmonic coronary artery anomaly that may enhance the risk of complications during balloon pulmonary valvuloplasty. A descriptive naming convention for coronary artery anomalies in dogs is also presented, which may be preferable to the older coding classification scheme. Copyright © 2013 Elsevier B.V. All rights reserved.
De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D.; Costantino, Maria Laura
2016-01-01
Introduction Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy, the latter display better fluid dynamic behaviour but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the haemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of two groups of newly developed supra-annular tri-leaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. Methods Two types of Poli-Valves made of SBC differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. An ad - hoc designed pulse duplicator allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the valve’s behaviour. Results Both types Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by ISO 5840 Standard. Results were compared with five mechanical heart valves (MHVs) and five tissue heart valves (THVs), currently available on the market. Conclusion Based on these results, polymeric heart valves based on styrenic block copolymers, as Poli-Valves are, can be considered as promising alternative for heart valve replacement in near future. PMID:26689146
De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D; Costantino, Maria Laura
2015-11-01
Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy; the latter display better fluid dynamic behavior but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the hemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of 2 groups of newly developed supra-annular, trileaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. 2 types of Poli-Valves made of SBC and differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. A pulse duplicator designed ad hoc allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the behavior of the valve. Both types of Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by the ISO 5840 Standard. Results were compared with 5 mechanical heart valves (MHVs) and 5 tissue heart valves (THVs), currently available on the market. Based on these results, PHVs based on styrenic block copolymers, as are Poli-Valves, can be considered a promising alternative for heart valve replacement in the near future.
Computational Modeling of Liquid and Gaseous Control Valves
NASA Technical Reports Server (NTRS)
Daines, Russell; Ahuja, Vineet; Hosangadi, Ashvin; Shipman, Jeremy; Moore, Arden; Sulyma, Peter
2005-01-01
In this paper computational modeling efforts undertaken at NASA Stennis Space Center in support of rocket engine component testing are discussed. Such analyses include structurally complex cryogenic liquid valves and gas valves operating at high pressures and flow rates. Basic modeling and initial successes are documented, and other issues that make valve modeling at SSC somewhat unique are also addressed. These include transient behavior, valve stall, and the determination of flow patterns in LOX valves. Hexahedral structured grids are used for valves that can be simplifies through the use of axisymmetric approximation. Hybrid unstructured methodology is used for structurally complex valves that have disparate length scales and complex flow paths that include strong swirl, local recirculation zones/secondary flow effects. Hexahedral (structured), unstructured, and hybrid meshes are compared for accuracy and computational efficiency. Accuracy is determined using verification and validation techniques.
Deep wells integrated with microfluidic valves for stable docking and storage of cells.
Jang, Yun-Ho; Kwon, Cheong Hoon; Kim, Sang Bok; Selimović, Seila; Sim, Woo Young; Bae, Hojae; Khademhosseini, Ali
2011-02-01
In this paper, we describe a microfluidic mechanism that combines microfluidic valves and deep wells for cell localization and storage. Cells are first introduced into the device via externally controlled flow. Activating on-chip valves was used to interrupt the flow and to sediment the cells floating above the wells. Thus, valves could be used to localize the cells in the desired locations. We quantified the effect of valves in the cell storage process by comparing the total number of cells stored with and without valve activation. We hypothesized that in deep wells external flows generate low shear stress regions that enable stable, long-term docking of cells. To assess this hypothesis we conducted numerical calculations to understand the influence of well depth on the forces acting on cells. We verified those predictions experimentally by comparing the fraction of stored cells as a function of the well depth and input flow rate upon activation of the valves. As expected, upon reintroduction of the flow the cells in the deep wells were not moved whereas those in shallow wells were washed away. Taken together, our paper demonstrates that deep wells and valves can be combined to enable a broad range of cell studies. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Gao, Leyi; Patterson, Eric E; Shippy, Scott A
2006-02-01
A simple automated nanoliter scale injection device which allows for reproducible 5 nL sample injections from samples with a volume of <1 microL is successfully used for conventional capillary electrophoresis (CE) and Hadamard transform (HT) CE detection. Two standard fused silica capillaries are assembled axially through the device to function as an injection and a separation capillary. Sample solution is supplied to the injection capillary using pressure controlled with a solenoid valve. Buffer solution flows gravimetrically by the junction of the injection and separation capillaries and is also gated with a solenoid valve. Plugs of sample are pushed into the space between the injection and separation capillaries for electrokinectic injection. To evaluate the performance of the injection device, several optimizations are performed including the influence of flow rates, the injected sample volume and the control of the buffer transverse flow on the overall sensitivity. The system was then applied to HT-CE-UV detection for the signal-to-noise ratio (S/N) improvement of the nitric oxide (NO) metabolites, nitrite and nitrate. In addition, signal averaging was performed to explore the possibility of greater sensitivity enhancements compared to single injections.
Zhang, Xiaoming; Zeraati, Mohammad; Kinnick, Randall R; Greenleaf, James F; Fatemi, Mostafa
2007-06-01
A new method for imaging the vibration mode of an object is investigated. The radiation force of ultrasound is used to scan the object at a resonant frequency of the object. The vibration of the object is measured by laser and the resulting acoustic emission from the object is measured by a hydrophone. It is shown that the measured signal is proportional to the value of the mode shape at the focal point of the ultrasound beam. Experimental studies are carried out on a mechanical heart valve and arterial phantoms. The mode images on the valve are made by the hydrophone measurement and confirmed by finite-element method simulations. Compared with conventional B-scan imaging on arterial phantoms, the mode imaging can show not only the interface of the artery and the gelatin, but also the vibration modes of the artery. The images taken on the phantom surface suggest that an image of an interior artery can be made by vibration measurements on the surface of the body. However, the image of the artery can be improved if the vibration of the artery is measured directly. Imaging of the structure in the gelatin or tissue can be enhanced by small bubbles and contrast agents.
Network Flow Simulation of Fluid Transients in Rocket Propulsion Systems
NASA Technical Reports Server (NTRS)
Bandyopadhyay, Alak; Hamill, Brian; Ramachandran, Narayanan; Majumdar, Alok
2011-01-01
Fluid transients, also known as water hammer, can have a significant impact on the design and operation of both spacecraft and launch vehicle propulsion systems. These transients often occur at system activation and shutdown. The pressure rise due to sudden opening and closing of valves of propulsion feed lines can cause serious damage during activation and shutdown of propulsion systems. During activation (valve opening) and shutdown (valve closing), pressure surges must be predicted accurately to ensure structural integrity of the propulsion system fluid network. In the current work, a network flow simulation software (Generalized Fluid System Simulation Program) based on Finite Volume Method has been used to predict the pressure surges in the feed line due to both valve closing and valve opening using two separate geometrical configurations. The valve opening pressure surge results are compared with experimental data available in the literature and the numerical results compared very well within reasonable accuracy (< 5%) for a wide range of inlet-to-initial pressure ratios. A Fast Fourier Transform is preformed on the pressure oscillations to predict the various modal frequencies of the pressure wave. The shutdown problem, i.e. valve closing problem, the simulation results are compared with the results of Method of Characteristics. Most rocket engines experience a longitudinal acceleration, known as "pogo" during the later stage of engine burn. In the shutdown example problem, an accumulator has been used in the feed system to demonstrate the "pogo" mitigation effects in the feed system of propellant. The simulation results using GFSSP compared very well with the results of Method of Characteristics.
Low pacemaker incidence with continuous-sutured valves: a retrospective analysis.
Niclauss, Lars; Delay, Dominique; Pfister, Raymond; Colombier, Sebastien; Kirsch, Matthias; Prêtre, René
2017-06-01
Background Permanent pacemaker implantation after surgical aortic valve replacement depends on patient selection and risk factors for conduction disorders. We aimed to identify risk criteria and obtain a selected group comparable to patients assigned to transcatheter aortic valve implantation. Methods Isolated sutured aortic valve replacements in 994 patients treated from 2007 to 2015 were reviewed. Demographics, hospital stay, preexisting conduction disorders, surgical technique, and etiology in patients with and without permanent pacemaker implantation were compared. Reported outcomes after transcatheter aortic valve implantation were compared with those of a subgroup including only degenerative valve disease and first redo. Results The incidence of permanent pacemaker implantation was 2.9%. Longer hospital stay ( p = 0.01), preexisting rhythm disorders ( p < 0.001), complex prosthetic endocarditis ( p = 0.01), and complex redo ( p < 0.001) were associated with permanent pacemaker implantation. Although prostheses were sutured with continuous monofilament in the majority of cases (86%), interrupted pledgetted sutures were used more often in the pacemaker group ( p = 0.002). In the subgroup analysis, the incidence of permanent pacemaker implantation was 2%; preexisting rhythm disorders and the suture technique were still major risk factors. Conclusion Permanent pacemaker implantation depends on etiology, preexisting rhythm disorders, and suture technique, and the 2% incidence compares favorably with the reported 5- to 10-fold higher incidence after transcatheter aortic valve implantation. Cost analysis should take this into account. Often dismissed as minor complication, permanent pacemaker implantation increases the risks of endocarditis, impaired myocardial recovery, and higher mortality if associated with prosthesis regurgitation.
Nitric Oxide Synthase-3 Promotes Embryonic Development of Atrioventricular Valves
Liu, Yin; Lu, Xiangru; Xiang, Fu-Li; Lu, Man; Feng, Qingping
2013-01-01
Nitric oxide synthase-3 (NOS3) has recently been shown to promote endothelial-to-mesenchymal transition (EndMT) in the developing atrioventricular (AV) canal. The present study was aimed to investigate the role of NOS3 in embryonic development of AV valves. We hypothesized that NOS3 promotes embryonic development of AV valves via EndMT. To test this hypothesis, morphological and functional analysis of AV valves were performed in wild-type (WT) and NOS3−/− mice at postnatal day 0. Our data show that the overall size and length of mitral and tricuspid valves were decreased in NOS3−/− compared with WT mice. Echocardiographic assessment showed significant regurgitation of mitral and tricuspid valves during systole in NOS3−/− mice. These phenotypes were all rescued by cardiac specific NOS3 overexpression. To assess EndMT, immunostaining of Snail1 was performed in the embryonic heart. Both total mesenchymal and Snail1+ cells in the AV cushion were decreased in NOS3−/− compared with WT mice at E10.5 and E12.5, which was completely restored by cardiac specific NOS3 overexpression. In cultured embryonic hearts, NOS3 promoted transforming growth factor (TGFβ), bone morphogenetic protein (BMP2) and Snail1expression through cGMP. Furthermore, mesenchymal cell formation and migration from cultured AV cushion explants were decreased in the NOS3−/− compared with WT mice. We conclude that NOS3 promotes AV valve formation during embryonic heart development and deficiency in NOS3 results in AV valve insufficiency. PMID:24204893
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nagy, Edit, E-mail: edit.nagy@karolinska.se; Department of Cardiology, Karolinska University Hospital, Stockholm; Caidahl, Kenneth
Highlights: Black-Right-Pointing-Pointer Oxidative stress has been implicated in the pathomechanism of calcific aortic valve stenosis. Black-Right-Pointing-Pointer We assessed the transcript levels for PARP-1 (poly(ADP-ribose) polymerase), acts as a DNA damage nick sensor in stenotic valves. Black-Right-Pointing-Pointer Early stage of diseased tricuspid valves exhibited higher mRNA levels for PARP-1 compared to bicuspid valves. Black-Right-Pointing-Pointer The mRNA levels for PARP-1 inversely correlated with the clinical stenosis severity in tricuspid valves. Black-Right-Pointing-Pointer Our data demonstrated that DNA damage pathways might be associated with stenosis severity only in tricuspid valves. -- Abstract: Oxidative stress may contribute to the hemodynamic progression of aortic valve stenosis,more » and is associated with activation of the nuclear enzyme poly(ADP-ribose) polymerase (PARP) 1. The aim of the present study was to assess the transcriptional profile and the topological distribution of PARP-1 in human aortic valves, and its relation to the stenosis severity. Human stenotic aortic valves were obtained from 46 patients undergoing aortic valve replacement surgery and used for mRNA extraction followed by quantitative real-time PCR to correlate the PARP-1 expression levels with the non invasive hemodynamic parameters quantifying the stenosis severity. Primary isolated valvular interstitial cells (VICs) were used to explore the effects of cytokines and leukotriene C{sub 4} (LTC{sub 4}) on valvular PARP-1 expression. The thickened areas of stenotic valves with tricuspid morphology expressed significantly higher levels of PARP-1 mRNA compared with the corresponding part of bicuspid valves (0.501 vs 0.243, P = 0.01). Furthermore, the quantitative gene expression levels of PARP-1 were inversely correlated with the aortic valve area (AVA) (r = -0.46, P = 0.0469) and AVA indexed for body surface area (BSA) (r = -0.498; P = 0.0298) only in tricuspid aortic valves. LTC{sub 4} (1 nM) significantly elevated the mRNA levels of PARP-1 by 2.38-fold in VICs. Taken together, these data suggest that valvular DNA-damage pathways may be associated with inflammation and the stenosis severity in tricuspid aortic valves.« less
Wang, Yin; Chen, Si; Shi, Jiawei; Li, Geng; Dong, Nianguo
2016-03-01
This study aims to compare mid-long-term clinical outcomes between patients younger than 60 years of age undergoing bioprosthetic and mechanical aortic valve replacement. From January 2002 to December 2009, patients younger than 60 years of age who received Medtronic Hancock II porcine bioprostheses were selected and compared with those who received mechanical bi-leaflet valves in the aortic position. A stepwise logistic regression propensity score identified a subset of 112 evenly matched patient-pairs. Mid-long-term outcomes of survival, valve-related reoperations, thromboembolic events and bleeding events were assessed. The follow-up was only 95.1% complete. Fourteen measurable variables were statistically similar for the matched cohort. Postoperative in-hospital mortality was 3.6% (bioprosthetic valves) and 2.7% (mechanical valves) (P = 0.700). Survival at 5 and 10 years was 96.3 and 88.7% for patients receiving bioprosthetic valve replacement versus 96.3 and 87.9% for patients receiving mechanical valve replacement (P = 0.860), respectively. At 5 and 10 years after operations, freedom from valve-related reoperation was 97.2 and 94.8% for patients receiving mechanical valve replacement, and 96.3 and 90.2% for patients receiving bioprosthetic valve replacement (P = 0.296), respectively. There was no difference between freedom from thromboembolic events (P = 0.528) and bleeding events (P = 0.128) between the matched groups during the postoperative 10 years. In patients younger than 60 years of age undergoing aortic valve replacement, mid-long-term survival rate was similar for patients receiving bioprosthetic versus mechanical valve replacement. Bioprosthetic valves were associated with a trend for a lower risk of anticoagulation treatment and did not have significantly greater likelihood of a reoperation. These findings suggest that a bioprosthetic valve may be a reasonable choice for AVR in patients younger than 60 years of age. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Gunning, Paul S.; Saikrishnan, Neelakantan; Yoganathan, Ajit P.; McNamara, Laoise M.
2015-01-01
Transcatheter aortic valve replacements (TAVRs) are a percutaneous alternative to surgical aortic valve replacements and are used to treat patients with aortic valve stenosis. This minimally invasive procedure relies on expansion of the TAVR stent to radially displace calcified aortic valve leaflets against the aortic root wall. However, these calcium deposits can impede the expansion of the device causing distortion of the valve stent and pericardial tissue leaflets. The objective of this study was to elucidate the impact of eccentric TAVR stent distortion on the dynamic deformation of the tissue leaflets of the prosthesis in vitro. Dual-camera stereophotogrammetry was used to measure the regional variation in strain in a leaflet of a TAVR deployed in nominal circular and eccentric (eccentricity index = 28%) orifices, representative of deployed TAVRs in vivo. It was observed that (i) eccentric stent distortion caused incorrect coaptation of the leaflets at peak diastole resulting in a ‘peel-back’ leaflet geometry that was not present in the circular valve and (ii) adverse bending of the leaflet, arising in the eccentric valve at peak diastole, caused significantly higher commissure strains compared with the circular valve in both normotensive and hypertensive pressure conditions (normotension: eccentric = 13.76 ± 2.04% versus circular = 11.77 ± 1.61%, p = 0.0014, hypertension: eccentric = 15.07 ± 1.13% versus circular = 13.56 ± 0.87%, p = 0.0042). This study reveals that eccentric distortion of a TAVR stent can have a considerable impact on dynamic leaflet deformation, inducing deleterious bending of the leaflet and increasing commissures strains, which might expedite leaflet structural failure compared to leaflets in a circular deployed valve. PMID:26674192
Water system microbial check valve development
NASA Technical Reports Server (NTRS)
Colombo, G. V.; Greenley, D. R.; Putnam, D. F.
1978-01-01
Development work on a device for the Space Shuttle that will prevent the transfer of viable microorganisms within water systems is described. The device serves as a check valve in that it prevents the transfer or cross-contamination of microorganisms from a nonpotable system into a potable water system when these systems are interconnected. In this regard, the function of the device is similar to that of the air gap found in conventional one gravity systems. The device is essentially a bed of resin material impregnated with iodine. Basic design data for a variety of flow and temperature conditions are presented, together with results of challenging the beds with suspensions of seven microorganisms including aerobes, anaerobes, and spore formers.
[The continent ileostomy--indication and results].
Säuberli, H; Akovbiantz, A; Hahnloser, P
1982-01-01
Proctocolectomy with conventional ileostomy cures patients with severe ulcerative colitis, however ileostomy appliances had to be worn for the rest of their lives. The continent ileostomy as devised by Kock provides the patient with an intraabdominal ileal reservoir and a valve constructed by invaginating the efferent ileal segment into the reservoir. The patient empties his reservoir 2 to 3 times a day by inserting a catheter through the valve. Our experience with 45 patients is reported. In most cases the continent ileostomy was constructed as a second procedure after proctocolectomy. The construction of a continent ileostomy as a secondary procedure can be recommended in patients with proctocolectomy. It offers patients a life situation differing only insignificantly from that of normal persons.
Atluri, Pavan; Stetson, Robert L; Hung, George; Gaffey, Ann C; Szeto, Wilson Y; Acker, Michael A; Hargrove, W Clark
2016-02-01
Mitral valve surgery is increasingly performed through minimally invasive approaches. There are limited data regarding the cost of minimally invasive mitral valve surgery. Moreover, there are no data on the specific costs associated with mitral valve surgery. We undertook this study to compare the costs (total and subcomponent) of minimally invasive mitral valve surgery relative to traditional sternotomy. All isolated mitral valve repairs performed in our health system from March 2012 through September 2013 were analyzed. To ensure like sets of patients, only those patients who underwent isolated mitral valve repairs with preoperative Society of Thoracic Surgeons scores of less than 4 were included in this study. A total of 159 patients were identified (sternotomy, 68; mini, 91). Total incurred direct cost was obtained from hospital financial records. Analysis demonstrated no difference in total cost (operative and postoperative) of mitral valve repair between mini and sternotomy ($25,515 ± $7598 vs $26,049 ± $11,737; P = .74). Operative costs were higher for the mini cohort, whereas postoperative costs were significantly lower. Postoperative intensive care unit and total hospital stays were both significantly shorter for the mini cohort. There were no differences in postoperative complications or survival between groups. Minimally invasive mitral valve surgery can be performed with overall equivalent cost and shorter hospital stay relative to traditional sternotomy. There is greater operative cost associated with minimally invasive mitral valve surgery that is offset by shorter intensive care unit and hospital stays. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
3D Printed Multimaterial Microfluidic Valve.
Keating, Steven J; Gariboldi, Maria Isabella; Patrick, William G; Sharma, Sunanda; Kong, David S; Oxman, Neri
2016-01-01
We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics.
The power of disruptive technological innovation: Transcatheter aortic valve implantation.
Berlin, David B; Davidson, Michael J; Schoen, Frederick J
2015-11-01
We sought to evaluate the principles of disruptive innovation, defined as technology innovation that fundamentally shifts performance and utility metrics, as applied to transcatheter aortic valve implantation (TAVI). In particular, we considered implantation procedure, device design, cost, and patient population. Generally cheaper and lower performing, classical disruptive innovations are first commercialized in insignificant markets, promise lower margins, and often parasitize existing usage, representing unattractive investments for established market participants. However, despite presently high unit cost, TAVI is less invasive, treats a "new," generally high risk, patient population, and is generally done by a multidisciplinary integrated heart team. Moreover, at least in the short-term TAVI has not been lower-performing than open surgical aortic valve replacement in high-risk patients. We conclude that TAVI extends the paradigm of disruptive innovation and represents an attractive commercial opportunity space. Moreover, should the long-term performance and durability of TAVI approach that of conventional prostheses, TAVI will be an increasingly attractive commercial opportunity. © 2014 Wiley Periodicals, Inc.
New valve and bonding designs for microfluidic biochips containing proteins.
Lu, Chunmeng; Xie, Yubing; Yang, Yong; Cheng, Mark M-C; Koh, Chee-Guan; Bai, Yunling; Lee, L James; Juang, Yi-Je
2007-02-01
Two major concerns in the design and fabrication of microfluidic biochips are protein binding on the channel surface and protein denaturing during device assembly. In this paper, we describe new methods to solve these problems. A "fishbone" microvalve design based on the concept of superhydrophobicity was developed to replace the capillary valve in applications where the chip surface requires protein blocking to prevent nonspecific binding. Our experimental results show that the valve functions well in a CD-like ELISA device. The packaging of biochips containing pre-loaded proteins is also a challenging task since conventional sealing methods often require the use of high temperatures, electric voltages, or organic solvents that are detrimental to the protein activity. Using CO2 gas to enhance the diffusion of polymer molecules near the device surface can result in good bonding at low temperatures and low pressure. This bonding method has little influence on the activity of the pre-loaded proteins after bonding.
Strong Ferromagnetically-Coupled Spin Valve Sensor Devices for Droplet Magnetofluidics
Lin, Gungun; Makarov, Denys; Schmidt, Oliver G.
2015-01-01
We report a magnetofluidic device with integrated strong ferromagnetically-coupled and hysteresis-free spin valve sensors for dynamic monitoring of ferrofluid droplets in microfluidics. The strong ferromagnetic coupling between the free layer and the pinned layer of spin valve sensors is achieved by reducing the spacer thickness, while the hysteresis of the free layer is eliminated by the interplay between shape anisotropy and the strength of coupling. The increased ferromagnetic coupling field up to the remarkable 70 Oe, which is five-times larger than conventional solutions, brings key advantages for dynamic sensing, e.g., a larger biasing field giving rise to larger detection signals, facilitating the operation of devices without saturation of the sensors. Studies on the fundamental effects of an external magnetic field on the evolution of the shape of droplets, as enabled by the non-visual monitoring capability of the device, provides crucial information for future development of a magnetofluidic device for multiplexed assays. PMID:26024419
[Continent ileostomy--indication and possibilities].
Hahnloser, P; Säuberli, H; Geroulanos, S; Schauwecker, H H; Kock, N G
1975-06-21
Proctocolectomy with conventional ileostomy cures patients with severe ulcerative colitis but ileostomy appliances must be worn for the rest of their lives. The continent ileostomy, as devised by Kock, provides the patient with an intraabdominal ileal reservoir and a valve constructed by invaginating the efferent ileal segment into the reservoir. The patient empties his reservoir 2-3 times a day by inserting a catheter through the valve. Our experience with 14 patients is reported. The continent ileostomy was in most cases constructed as a second procedure after proctocolectomy. Minor postoperative complications, such as abscess, fistula or partial luxation of the valve were easily corrected. One patient who underwent proctocolectomy and simultaneous construction of a continent ileostomy died in acute liver failure due to a severe preexisting cirrhosis. All the other patients are continent for feces and gas and do not need external appliances. The construction of a continent ileostomy as a secondary procedure can be recommended in patients with proctocolectomy. It offers patients a life situation with differs only insignificantly from that of normal persons.
Balmforth, Damian; Chacko, Jacob; Uppal, Rakesh
2016-10-01
A best evidence topic was constructed according to a structured protocol. The question addressed was whether (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) aids the diagnosis of prosthetic valve endocarditis (PVE)? A total of 107 publications were found using the reported search, of which 6 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. The reported outcome of all studies was a final diagnosis of confirmed endocarditis on follow-up. All the six studies were non-randomized, single-centre, observational studies and thus represented level 3 evidence. The diagnostic capability of PET/CT for PVE was compared with that of the modified Duke Criteria and echocardiography, and reported in terms of sensitivity, specificity and positive and negative predictive values. All studies demonstrated an increased sensitivity for the diagnosis of PVE when PET/CT was combined with the modified Duke Criteria on admission. A higher SUVmax on PET was found to be significantly associated with a confirmed diagnosis of endocarditis and an additional diagnostic benefit of PET/CT angiography over conventional PET/non-enhanced CT is reported due to improved anatomical resolution. However, PET/CT was found to be unreliable in the early postoperative period due to its inability to distinguish between infection and residual postoperative inflammatory changes. PET/CT was also found to be poor at diagnosing cases of native valve endocarditis. We conclude that PET/CT aids in the diagnosis of PVE when combined with the modified Duke Criteria on admission by increasing the diagnostic sensitivity. The diagnostic ability of PET/CT can be potentiated by the use of PET/CTA; however, its use may be unreliable in the early postoperative period or in native valve endocarditis. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Treatment of Post-Stent Gastroesophageal Reflux by Anti-Reflux Z-Stent
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davies, Roger Philip; Kew, Jacqueline; Byrne, Peter D.
2000-11-15
Severe symptoms of heartburn and retrosternal pain consistent with gastro-esophageal reflux (GER) developed in a patient following placement of a conventional self-expanding 16-24-mm-diameter x 12-cm-long esophageal stent across the gastroesophageal junction to treat an obstructing esophageal carcinoma. A second 18-mm-diameter x 10-cm-long esophageal stent with anti-reflux valve was deployed coaxially and reduced symptomatic GER immediately. Improvement was sustained at 4-month follow-up. An anti-reflux stent can be successfully used to treat significant symptomatic GER after conventional stenting.
Yin, Hongfeng; Killeen, Kevin; Brennen, Reid; Sobek, Dan; Werlich, Mark; van de Goor, Tom
2005-01-15
Current nano-LC/MS systems require the use of an enrichment column, a separation column, a nanospray tip, and the fittings needed to connect these parts together. In this paper, we present a microfabricated approach to nano-LC, which integrates these components on a single LC chip, eliminating the need for conventional LC connections. The chip was fabricated by laminating polyimide films with laser-ablated channels, ports, and frit structures. The enrichment and separation columns were packed using conventional reversed-phase chromatography particles. A face-seal rotary valve provided a means for switching between sample loading and separation configurations with minimum dead and delay volumes while allowing high-pressure operation. The LC chip and valve assembly were mounted within a custom electrospray source on an ion-trap mass spectrometer. The overall system performance was demonstrated through reversed-phase gradient separations of tryptic protein digests at flow rates between 100 and 400 nL/min. Microfluidic integration of the nano-LC components enabled separations with subfemtomole detection sensitivity, minimal carryover, and robust and stable electrospray throughout the LC solvent gradient.
Stähli, Barbara E.; Nguyen-Kim, Thi Dan Linh; Gebhard, Cathérine; Frauenfelder, Thomas; Tanner, Felix C.; Nietlispach, Fabian; Maisano, Francesco; Falk, Volkmar; Lüscher, Thomas F.; Maier, Willibald; Binder, Ronald K.
2015-01-01
Low-flow low-gradient severe aortic stenosis (LFLGAS) is associated with worse outcomes. Aortic valve calcification patterns of LFLGAS as compared to non-LFLGAS have not yet been thoroughly assessed. 137 patients undergoing transcatheter aortic valve replacement (TAVR) with preprocedural multidetector computed tomography (MDCT) and postprocedural transthoracic echocardiography were enrolled. Calcification characteristics were assessed by MDCT both for the total aortic valve and separately for each leaflet. 34 patients had LFLGAS and 103 non-LFLGAS. Total aortic valve calcification volume (p < 0.001), mass (p < 0.001), and density (p = 0.004) were lower in LFLGAS as compared to non-LFLGAS patients. At 30-day follow-up, mean transaortic pressure gradients and more than mild paravalvular regurgitation did not differ between groups. In conclusion, LFLGAS and non-LFLGAS express different calcification patterns which, however, did not impact on device success after TAVR. PMID:26435875
Patient-specific pediatric silicone heart valve models based on 3D ultrasound
NASA Astrophysics Data System (ADS)
Ilina, Anna; Lasso, Andras; Jolley, Matthew A.; Wohler, Brittany; Nguyen, Alex; Scanlan, Adam; Baum, Zachary; McGowan, Frank; Fichtinger, Gabor
2017-03-01
PURPOSE: Patient-specific heart and valve models have shown promise as training and planning tools for heart surgery, but physically realistic valve models remain elusive. Available proprietary, simulation-focused heart valve models are generic adult mitral valves and do not allow for patient-specific modeling as may be needed for rare diseases such as congenitally abnormal valves. We propose creating silicone valve models from a 3D-printed plastic mold as a solution that can be adapted to any individual patient and heart valve at a fraction of the cost of direct 3D-printing using soft materials. METHODS: Leaflets of a pediatric mitral valve, a tricuspid valve in a patient with hypoplastic left heart syndrome, and a complete atrioventricular canal valve were segmented from ultrasound images. A custom software was developed to automatically generate molds for each valve based on the segmentation. These molds were 3D-printed and used to make silicone valve models. The models were designed with cylindrical rims of different sizes surrounding the leaflets, to show the outline of the valve and add rigidity. Pediatric cardiac surgeons practiced suturing on the models and evaluated them for use as surgical planning and training tools. RESULTS: Five out of six surgeons reported that the valve models would be very useful as training tools for cardiac surgery. In this first iteration of valve models, leaflets were felt to be unrealistically thick or stiff compared to real pediatric leaflets. A thin tube rim was preferred for valve flexibility. CONCLUSION: The valve models were well received and considered to be valuable and accessible tools for heart valve surgery training. Further improvements will be made based on surgeons' feedback.
Trauzeddel, Ralf Felix; Löbe, Ulrike; Barker, Alex J; Gelsinger, Carmen; Butter, Christian; Markl, Michael; Schulz-Menger, Jeanette; von Knobelsdorff-Brenkenhoff, Florian
2016-03-01
Ascending aortic blood flow characteristics are altered after aortic valve surgery, but the effect of transcatheter aortic valve implantation (TAVI) is unknown. Abnormal flow may be associated with aortic and cardiac remodeling. We analyzed blood flow characteristics in the ascending aorta after TAVI in comparison to conventional stented aortic bioprostheses (AVR) and healthy subjects using time-resolved three-dimensional flow-sensitive cardiovascular magnetic resonance imaging (4D-flow MRI). Seventeen patients with TAVI (Edwards Sapien XT), 12 with AVR and 9 healthy controls underwent 4D-flow MRI of the ascending aorta. Target parameters were: severity of vortical and helical flow pattern (semiquantitative grading from 0 = none to 3 = severe) and the local distribution of systolic wall shear stress (WSSsystole). AVR revealed significantly more extensive vortical and helical flow pattern than TAVI (p = 0.042 and p = 0.002) and controls (p < 0.001 and p = 0.001). TAVI showed significantly more extensive vortical flow than controls (p < 0.001). Both TAVI and AVR revealed marked blood flow eccentricity (64.7 and 66.7%, respectively), whereas controls showed central blood flow (88.9%). TAVI and AVR exhibited an asymmetric distribution of WSSsystole in the mid-ascending aorta with local maxima at the right anterior aortic wall and local minima at the left posterior wall. In contrast, controls showed a symmetric distribution of WSSsystole along the aortic circumference. Blood flow was significantly altered in the ascending aorta after TAVI and AVR. Changes were similar regarding WSSsystole distribution, while TAVI resulted in less helical and vortical blood flow.
Shakil, S S; Ahmed, C M; Khaled, F I; Nahar, S; Perveen, R; Pandit, H; Osmani, D M
2017-10-01
Mitral valve is the most involved valve in rheumatic heart disease especially in the form of mitral stenosis. Treatment options of mitral stenosis depend upon pattern, extent & the severity of disease and echocardiography has the key role in this area. Severity of involvement of subvalvular apparatus (SVA) is an important factor for determining the treatment option. 2D echocardiography (2DE) is conventionally used. With the advancement of echocardiographic technology 3D echocardiography (3DE) would offer better assessment of subvalvular apparatus. This study compared transthoracic 2D versus 3D echocardiography for assessment of SVA in chronic rheumatic mitral valve disease. This cross sectional observational study was done in University cardiac centre, Bangabandhu Sheikh Mujib Medical University, Dhaka, Bangladesh from May 2012 to October 2012. In this study, considering all ethical issues, data were collected from 50 subjects who underwent transthoracic 2D and 3D echocardiography for the assessment of extent and severity of mitral stenosis. Accurate measurement of Mitral valvular area is very important in assessment of severity, which is found similar by both 2DE (0.98±0.24cm²) and 3DE (0.92 ±0.23cm²). But assessment of subvalvular involvement especially chordal adhesion can be done better by 3DE (p<0.001). This observation suggests superiority of 3DE for assessment of SVA in chronic rheumatic mitral stenosis. The result of the study demonstrates that 3DE is superior to 2DE for the assessment of SVA in chronic rheumatic mitral stenosis.
Loger, K; Engel, A; Haupt, J; Lima de Miranda, R; Lutter, G; Quandt, E
2016-03-01
Heart valves are constantly exposed to high dynamic loading and are prone to degeneration. Therefore, it is a challenge to develop a durable heart valve substitute. A promising approach in heart valve engineering is the development of hybrid scaffolds which are composed of a mechanically strong inorganic mesh enclosed by valvular tissue. In order to engineer an efficient, durable and very thin heart valve for transcatheter implantations, we developed a fabrication process for microstructured heart valve leaflets made from a nickel-titanium (NiTi) thin film shape memory alloy. To examine the capability of microstructured NiTi thin film as a matrix scaffold for tissue engineered hybrid heart valves, leaflets were successfully seeded with smooth muscle cells (SMCs). In vitro pulsatile hydrodynamic testing of the NiTi thin film valve leaflets demonstrated that the SMC layer significantly improved the diastolic sufficiency of the microstructured leaflets, without affecting the systolic efficiency. Compared to an established porcine reference valve model, magnetron sputtered NiTi thin film material demonstrated its suitability for hybrid tissue engineered heart valves.
Mvondo, Charles Mve; Pugliese, Marta; Giamberti, Alessandro; Chelo, David; Kuate, Liliane Mfeukeu; Boombhi, Jerome; Dailor, Ellen Marie
2016-01-01
Rheumatic valve disease, a consequence of acute rheumatic fever, remains endemic in developing countries in the sub-Saharan region where it is the leading cause of heart failure and cardiovascular death, involving predominantly a young population. The involvement of the mitral valve is pathognomonic and mitral surgery has become the lone therapeutic option for the majority of these patients. However, controversies exist on the choice between valve repair or prosthetic valve replacement. Although the advantages of mitral valve repair over prosthetic valve replacement in degenerative mitral disease are well established, this has not been the case for rheumatic lesions, where the use of prosthetic valves, specifically mechanical devices, even in poorly compliant populations remains very common. These patients deserve more accurate evaluation in the choice of the surgical strategy which strongly impacts the post-operative outcomes. This report discusses the factors supporting mitral repair surgery in rheumatic disease, according to the patients' characteristics and the effectiveness of the current repair techniques compared to prosthetic valve replacement in developing countries.
Ischemic Stroke in a Patient With Quadricuspid Aortic Valve and Patent Foramen Ovale
Spartalis, Michael; Tzatzaki, Eleni; Spartalis, Eleftherios; Damaskos, Christos; Moris, Demetrios; Tsiapras, Dimitrios; Voudris, Vassilis
2017-01-01
Quadricuspid aortic valve (QAV) is a rare congenital aortic valve abnormality. It is less common as compared to bicuspid or unicuspid aortic valve abnormality. QAV causes aortic regurgitation usually in the fifth to sixth decade of life. We present a rare case of a female patient with cryptogenic stroke due to a QAV and a patent foramen ovale (PFO). The patient underwent transcatheter closure of PFO, as there was no clear indication for surgery for her valve. Surgical removal remains the method of choice for the treatment of the QAV before left ventricular decompensation occurs. PMID:28868103
Ischemic Stroke in a Patient With Quadricuspid Aortic Valve and Patent Foramen Ovale.
Spartalis, Michael; Tzatzaki, Eleni; Spartalis, Eleftherios; Damaskos, Christos; Moris, Demetrios; Tsiapras, Dimitrios; Voudris, Vassilis
2017-08-01
Quadricuspid aortic valve (QAV) is a rare congenital aortic valve abnormality. It is less common as compared to bicuspid or unicuspid aortic valve abnormality. QAV causes aortic regurgitation usually in the fifth to sixth decade of life. We present a rare case of a female patient with cryptogenic stroke due to a QAV and a patent foramen ovale (PFO). The patient underwent transcatheter closure of PFO, as there was no clear indication for surgery for her valve. Surgical removal remains the method of choice for the treatment of the QAV before left ventricular decompensation occurs.
Heart valve replacement with the Sorin tilting-disc prosthesis. A 10-year experience.
Milano, A; Bortolotti, U; Mazzucco, A; Mossuto, E; Testolin, L; Thiene, G; Gallucci, V
1992-02-01
From 1978 to 1988, 697 patients with a mean age of 48 +/- 11 years (range 5 to 75 years) received a Sorin tilting-disc prosthesis; 358 had had aortic valve replacement, 247 mitral valve replacement, and 92 mitral and aortic valve replacement. Operative mortality rates were 7.8%, 11.3%, and 10.8%, respectively, in the three groups. Cumulative duration of follow-up is 1650 patient-years for aortic valve replacement (maximum follow-up 11.4 years), 963 patient-years for mitral valve replacement (maximum follow-up 9.9 years) and 328 patient-years for mitral and aortic valve replacement (maximum follow-up 9.4 years). Actuarial survival at 9 years is 72% +/- 4% after mitral valve replacement, 70% +/- 3% after aortic valve replacement, and 50% +/- 12% after mitral and aortic valve replacement, and actuarial freedom from valve-related deaths is 97% +/- 2% after mitral valve replacement, 92% +/- 2% after aortic valve replacement, and 62% +/- 15% after mitral and aortic valve replacement. Thromboembolic events occurred in 21 patients with aortic valve replacement (1.3% +/- 0.2%/pt-yr), in 12 with mitral valve replacement (1.2% +/- 0.3% pt-yr), and in seven with mitral and aortic valve replacement (2.1% +/- 0.8%), with one case of prosthetic thrombosis in each group; actuarial freedom from thromboembolism at 9 years is 92% +/- 3% after mitral valve replacement, 91% +/- 3% after aortic valve replacement, and 74% +/- 16% after mitral and aortic valve replacement. Anticoagulant-related hemorrhage was observed in 15 patients after aortic valve replacement (0.9% +/- 0.2%/pt-yr), in 9 after mitral valve replacement (0.9% +/- 0.3%/pt-yr), and in 6 with mitral and aortic valve replacement (0.9% +/- 0.5%/pt-yr); actuarial freedom from this complication at 9 years is 94% +/- 2% after aortic valve replacement, 91% +/- 4% after mitral valve replacement, and 68% +/- 16% after mitral and aortic valve replacement. Actuarial freedom from reoperation at 9 years is 97% +/- 2% after mitral and aortic valve replacement, 92% +/- 4% after mitral valve replacement, and 89% +/- 3% after aortic valve replacement, with no cases of mechanical fracture. The Sorin valve has shown a satisfactory long-term overall performance, comparable with other mechanical prostheses, and an excellent durability that renders it a reliable heart valve substitute for the mitral and aortic positions.
Static Flow Characteristics of a Mass Flow Injecting Valve
NASA Technical Reports Server (NTRS)
Mattern, Duane; Paxson, Dan
1995-01-01
A sleeve valve is under development for ground-based forced response testing of air compression systems. This valve will be used to inject air and to impart momentum to the flow inside the first stage of a multi-stage compressor. The valve was designed to deliver a maximum mass flow of 0.22 lbm/s (0.1 kg/s) with a maximum valve throat area of 0.12 sq. in (80 sq. mm), a 100 psid (689 KPA) pressure difference across the valve and a 68 F, (20 C) air supply. It was assumed that the valve mass flow rate would be proportional to the valve orifice area. A static flow calibration revealed a nonlinear valve orifice area to mass flow relationship which limits the maximum flow rate that the valve can deliver. This nonlinearity was found to be caused by multiple choking points in the flow path. A simple model was used to explain this nonlinearity and the model was compared to the static flow calibration data. Only steady flow data is presented here. In this report, the static flow characteristics of a proportionally controlled sleeve valve are modelled and validated against experimental data.
Mitral Valve Clip for Treatment of Mitral Regurgitation: An Evidence-Based Analysis
Ansari, Mohammed T.; Ahmadzai, Nadera; Coyle, Kathryn; Coyle, Doug; Moher, David
2015-01-01
Background Many of the 500,000 North American patients with chronic mitral regurgitation may be poor candidates for mitral valve surgery. Objective The objective of this study was to investigate the comparative effectiveness, harms, and cost-effectiveness of percutaneous mitral valve repair using mitral valve clips in candidates at prohibitive risk for surgery. Data Sources We searched articles in MEDLINE, Embase, and the Cochrane Library published from 1994 to February 2014 for evidence of effectiveness and harms; for economic literature we also searched NHS EED and Tufts CEA registry. Grey literature was also searched. Review Methods Primary studies were sought from existing systematic reviews that had employed reliable search and screening methods. Newer studies were sought by searching the period subsequent to the last search date of the review. Two reviewers screened records and assessed study validity. We used the Cochrane risk of bias tool for randomized, generic assessment for non-randomized studies, and the Phillips checklist for economic studies. Results Ten studies including 1 randomized trial were included. The majority of the direct comparative evidence compared the mitral valve clip repair with surgery in patients not particularly at prohibitive surgical risk. Irrespective of degenerative or functional chronic mitral regurgitation etiology, evidence of effectiveness and harms is inconclusive and of very low quality. Very-low-quality evidence indicates that percutaneous mitral valve clip repair may provide a survival advantage, at least during the first 1 to 2 years, particularly in medically managed chronic functional mitral regurgitation. Because of limitations in the design of studies, the cost-effectiveness of mitral valve clips in patients at prohibitive risk for surgery also could not be established. Limitations Because of serious concerns of risk of bias, indirectness, and imprecision, evidence is of very low quality. Conclusions No meaningful conclusions can be drawn about the comparative effectiveness, harms, and cost-effectiveness of mitral valve clips in the population with chronic mitral regurgitation who are at prohibitive risk for surgery. PMID:26379810
Kretzschmar, Daniel; Lauten, Alexander; Goebel, Bjoern; Doenst, Torsten; Poerner, Tudor C; Ferrari, Markus; Figulla, Hans R; Hamadanchi, Ali
2016-03-01
The assessment of aortic annular size is critical, and inappropriate sizing is thought to be a main reason of paravalvular aortic regurgitation. Multidetector computed tomograph is associated with the risk of contrast nephropathy. For optimal evaluation of the complex structure of the aortic annulus, three-dimensional (3D)-methods should be used. We therefore sought to determine the value of 3D-transoesophageal echocardiography (3D-TEE) for appropriate sizing. Hundred and one patients (mean age 81·4 years) with symptomatic aortic valve stenosis (AS) and high surgical risk profile (mean log. EuroScore 28·8%) being scheduled for transcatheter aortic valve implantation (TAVI) were included. 2D- and 3D-TEE were performed before the procedure to evaluate the aortic annulus diameter. Maximum, minimum and mean (max diameter + min diameter/2) annulus diameters were 24·7, 23·1 and 23. 9 mm in 3D-TEE and compared to 22·6 mm in 2D-TEE (P<0·001; 0·07; <0·001). The interobserver variability for 3D-TEE was low with a mean difference of 0·18 mm compared to 2D-TEE with 0·59 mm. The application of 3D-TEE caused a change of prosthesis size selection in 40% of patients compared to 2D-TEE. In this study, we implanted three different types of catheter-mounted valves (Edwards-SAPIEN(™) XT valve, CoreValve(™) and JenaValve(™) ). Final angiography confirmed valve competence (mild insufficiency) in 91%, and there was no aortic regurgitation greater than moderate in the follow-up echocardiographic evaluation. Assessment of aortic annulus dimensions for TAVI size selection can safely be performed with 3D-TEE only. Based on our results with significantly higher annulus diameter compared to 2D-TEE, we recommend 3D-TEE to reduce prosthesis undersizing. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Analysis of hydrodynamic losses for various types of aortic valves
NASA Astrophysics Data System (ADS)
Starobin, I. M.; Lupachev, S. P.; Dolgopolov, R. V.; Zaiko, V. M.; Kas'yanov, V. A.; Mungalov, D. D.; Morov, G. V.
1985-05-01
The creation of an automated computer-controlled hydraulic stand made it possible to measure the main hydrodynamic parameters of the flow through the investigated HVP and to determine the coefficients of Eq. (2) of fluid flow in the test chamber of the stand. The coefficients found can serve as a criterion of a comparative assessment of the hydrodynamics of HVPs. An analysis of the coefficients showed that the main contribution to pressure losses across ball and disc valves is made by viscous and convective effects. An analysis of inertial losses confirmed the presence of oscillations of the ball closing elements of the AKCh-3-06 valve around the props of the stroke limiters and made it possible to assess them quantitatively. For leaflet valves the contribution of inertial losses to the total pressure losses is more considerable than in the case of disc and ball valves both in the regime of an increase of power of the output and in the regime of a constant power. The mechanical properties of the material of leaflet valves have an effect on the hydrodynamic characteristics. The advantage of the investigated leaflet valves consists not only in that they have smaller total hydraulic losses compared with the other valves, but also in that they provide a high amplitude of pulsations of the blood stream in the case of insufficient contractility of the heart.
Hamatani, Yasuhiro; Ishibashi-Ueda, Hatsue; Nagai, Toshiyuki; Sugano, Yasuo; Kanzaki, Hideaki; Yasuda, Satoshi; Fujita, Tomoyuki; Kobayashi, Junjiro; Anzai, Toshihisa
2016-01-01
Background Congenital bicuspid aortic valve (CBAV) is the main cause of aortic stenosis (AS) in young adults. However, the histopathological features of AS in patients with CBAV have not been fully investigated. Methods and Results We examined specimens of aortic valve leaflets obtained from patients who had undergone aortic valve re/placement at our institution for severe AS with CBAV (n = 24, CBAV-AS group), severe AS with tricuspid aortic valve (n = 24, TAV-AS group), and severe aortic regurgitation (AR) with CBAV (n = 24, CBAV-AR group). We compared the histopathological features among the three groups. Pathological features were classified using semi-quantitative methods (graded on a scale 0 to 3) by experienced pathologists without knowledge of the patients’ backgrounds. The severity of inflammation, neovascularization, and calcium and cholesterol deposition did not differ between the CBAV-AS and TAV-AS groups, and these four parameters were less marked in the CBAV-AR group than in the CBAV-AS (all p<0.01). Meanwhile, the grade of valvular fibrosis was greater in the CBAV-AS group, compared with the TAV-AS and CBAV-AR groups (both p<0.01). In AS patients, thickness of fibrotic lesions was greater on the aortic side than on the ventricular side (both p<0.01). Meanwhile, thickness of fibrotic lesions was comparable between the aortic and ventricular sides in CBAV-AR patients (p = 0.35). Conclusions Valvular fibrosis, especially on the aortic side, was greater in patients with CBAV-AS than in those without, suggesting a difference in the pathogenesis of AS between CBAV and TAV. PMID:27479126
Sugeng, Lissa; Shernan, Stanton K; Weinert, Lynn; Shook, Doug; Raman, Jai; Jeevanandam, Valluvan; DuPont, Frank; Fox, John; Mor-Avi, Victor; Lang, Roberto M
2008-12-01
Recently, a novel real-time 3-dimensional (3D) matrix-array transesophageal echocardiographic (3D-MTEE) probe was found to be highly effective in the evaluation of native mitral valves (MVs) and other intracardiac structures, including the interatrial septum and left atrial appendage. However, the ability to visualize prosthetic valves using this transducer has not been evaluated. Moreover, the diagnostic accuracy of this new technology has never been validated against surgical findings. This study was designed to (1) assess the quality of 3D-MTEE images of prosthetic valves and (2) determine the potential value of 3D-MTEE imaging in the preoperative assessment of valvular pathology by comparing images with surgical findings. Eighty-seven patients undergoing clinically indicated transesophageal echocardiography were studied. In 40 patients, 3D-MTEE images of prosthetic MVs, aortic valves (AVs), and tricuspid valves (TVs) were scored for the quality of visualization. For both MVs and AVs, mechanical and bioprosthetic valves, the rings and leaflets were scored individually. In 47 additional patients, intraoperative 3D-MTEE diagnoses of MV pathology obtained before initiating cardiopulmonary bypass were compared with surgical findings. For the visualization of prosthetic MVs and annuloplasty rings, quality was superior compared with AV and TV prostheses. In addition, 3D-MTEE imaging had 96% agreement with surgical findings. Three-dimensional matrix-array transesophageal echocardiographic imaging provides superb imaging and accurate presurgical evaluation of native MV pathology and prostheses. However, the current technology is less accurate for the clinical assessment of AVs and TVs. Fast acquisition and immediate online display will make this the modality of choice for MV surgical planning and postsurgical follow-up.
Cardiac findings in Quarter Horses with heritable equine regional dermal asthenia.
Brinkman, Erin L; Weed, Benjamin C; Patnaik, Sourav S; Brazile, Bryn L; Centini, Ryan M; Wills, Robert W; Olivier, Bari; Sledge, Dodd G; Cooley, Jim; Liao, Jun; Rashmir-Raven, Ann M
2017-03-01
OBJECTIVE To compare biomechanical and histologic features of heart valves and echocardiographic findings between Quarter Horses with and without heritable equine regional dermal asthenia (HERDA). DESIGN Prospective case-control study. ANIMALS 41 Quarter Horses. PROCEDURES Ultimate tensile strength (UTS) of aortic and mitral valve leaflets was assessed by biomechanical testing in 5 horses with HERDA and 5 horses without HERDA (controls). Histologic evaluation of aortic and mitral valves was performed for 6 HERDA-affected and 3 control horses. Echocardiography was performed in 14 HERDA-affected and 11 control horses. Biomechanical data and echocardiographic variables of interest were compared between groups by statistical analyses, RESULTS Mean values for mean and maximum UTS of heart valves were significantly lower in HERDA-affected horses than in controls. Blood vessels were identified in aortic valve leaflets of HERDA-affected but not control horses. Most echocardiographic data did not differ between groups. When the statistical model for echocardiographic measures was controlled for body weight, mean and maximum height and width of the aorta at the valve annulus in short-axis images were significantly associated with HERDA status and were smaller for affected horses. CONCLUSIONS AND CLINICAL RELEVANCE Lower UTS of heart valves in HERDA-affected horses, compared with those of control horses, supported that tissues other than skin with high fibrillar collagen content are abnormal in horses with HERDA. Lack of significant differences in most echocardiographic variables between affected and control horses suggested that echocardiography may not be useful to detect a substantial loss of heart valve tensile strength. Further investigation is warranted to confirm these findings. Studies in horses with HERDA may provide insight into cardiac abnormalities in people with collagen disorders.
Lester, Patrick A; Coleman, Dawn M; Diaz, Jose A; Jackson, Tatum O; Hawley, Angela E; Mathues, Angela R; Grant, Brandon T; Knabb, Robert M; Ramacciotti, Eduardo; Frost, Charles E; Song, Yan; Wakefield, Thomas W; Myers, Daniel D
2017-05-01
Warfarin is the current standard for oral anticoagulation therapy in patients with mechanical heart valves, yet optimal therapy to maximize anticoagulation and minimize bleeding complications requires routine coagulation monitoring, possible dietary restrictions, and drug interaction monitoring. As alternatives to warfarin, oral direct acting factor Xa inhibitors are currently approved for the prophylaxis and treatment of venous thromboembolism and reduction of stroke and systemic embolization. However, no in vivo preclinical or clinical studies have been performed directly comparing oral factor Xa inhibitors such as apixaban to warfarin, the current standard of therapy. A well-documented heterotopic aortic valve porcine model was used to test the hypothesis that apixaban has comparable efficacy to warfarin for thromboprophylaxis of mechanical heart valves. Sixteen swine were implanted with a bileaflet mechanical aortic valve that bypassed the ligated descending thoracic aorta. Animals were randomized to 4 groups: control (no anticoagulation; n=4), apixaban oral 1 mg/kg twice a day (n=5), warfarin oral 0.04 to 0.08 mg/kg daily (international normalized ratio 2-3; n=3), and apixaban infusion (n=4). Postmortem valve thrombus was measured 30 days post-surgery for control-oral groups and 14 days post-surgery for the apixaban infusion group. Control thrombus weight (mean) was significantly different (1422.9 mg) compared with apixaban oral (357.5 mg), warfarin (247.1 mg), and apixiban 14-day infusion (61.1 mg; P <0.05). Apixaban is a promising candidate and may be a useful alternative to warfarin for thromboprophylaxis of mechanical heart valves. Unlike warfarin, no adverse bleeding events were observed in any apixaban groups. © 2017 American Heart Association, Inc.
Giese, Daniel; Weiss, Kilian; Baeßler, Bettina; Madershahian, Navid; Choi, Yeong-Hoon; Maintz, David; Bunck, Alexander C
2018-02-01
The objective of the current work was to evaluate flow and turbulent kinetic energy in different transcatheter aortic valve implants using highly undersampled time-resolved multi-point 3-directional phase-contrast measurements (4D Flow MRI) in an in vitro setup. A pulsatile flow setup was used with a compliant tubing mimicking a stiff left ventricular outflow tract and ascending aorta. Five different implants were measured using a highly undersampled multi-point 4D Flow MRI sequence. Velocities and turbulent kinetic energy values were analysed and compared. Strong variations of turbulent kinetic energy distributions between the valves were observed. Maximum turbulent kinetic energy values ranged from 100 to over 500 J/m 3 while through-plane velocities were similar between all valves. Highly accelerated 4D Flow MRI for the measurement of velocities and turbulent kinetic energy values allowed for the assessment of hemodynamic parameters in five different implant models. The presented setup, measurement protocol and analysis methods provides an efficient approach to compare different valve implants and could aid future novel valve designs.
Diagnostic for two-mode variable valve activation device
Fedewa, Andrew M
2014-01-07
A method is provided for diagnosing a multi-mode valve train device which selectively provides high lift and low lift to a combustion valve of an internal combustion engine having a camshaft phaser actuated by an electric motor. The method includes applying a variable electric current to the electric motor to achieve a desired camshaft phaser operational mode and commanding the multi-mode valve train device to a desired valve train device operational mode selected from a high lift mode and a low lift mode. The method also includes monitoring the variable electric current and calculating a first characteristic of the parameter. The method also includes comparing the calculated first characteristic against a predetermined value of the first characteristic measured when the multi-mode valve train device is known to be in the desired valve train device operational mode.
3D Printed Multimaterial Microfluidic Valve
Patrick, William G.; Sharma, Sunanda; Kong, David S.; Oxman, Neri
2016-01-01
We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics. PMID:27525809
Study of fuel systems for LH2-fueled subsonic transport aircraft, volume 1
NASA Technical Reports Server (NTRS)
Brewer, G. D.; Morris, R. E.; Davis, G. W.; Versaw, E. F.; Cunnington, G. R., Jr.; Riple, J. C.; Baerst, C. F.; Garmong, G.
1978-01-01
Several engine concepts examined to determine a preferred design which most effectively exploits the characteristics of hydrogen fuel in aircraft tanks received major emphasis. Many candidate designs of tank structure and cryogenic insulation systems were evaluated. Designs of all major elements of the aircraft fuel system including pumps, lines, valves, regulators, and heat exchangers received attention. Selected designs of boost pumps to be mounted in the LH2 tanks, and of a high pressure pump to be mounted on the engine were defined. A final design of LH2-fueled transport aircraft was established which incorporates a preferred design of fuel system. That aircraft was then compared with a conventionally fueled counterpart designed to equivalent technology standards.
2010-01-01
Background This study was undertaken to compare mitral valve repair and replacement as treatments for ischemic mitral regurgitation (IMR) with left ventricular dysfunction (LVD). Specifically, we sought to determine whether the choice of mitral valve procedure affected survival, and discover which patients were predicted to benefit from mitral valve repair and which from replacement. Methods A total of 218 consecutive patients underwent either mitral valve repair (MVP, n = 112) or mitral valve replacement (MVR, n = 106). We retrospectively reviewed the clinical material, operation methods, echocardiography check during operation and follow-up. Patients details and follow-up outcomes were compared using multivariate and Kaplan-Meier analyses. Results No statistical difference was found between the two groups in term of intraoperative data. Early mortality was 3.2% (MVP 2.7% and MVR 3.8%). At discharge, Left ventricular end-systolic and end-diastolic diameter and left ventricular ejection fraction (LVEF) were improved more in the MVP group than MVR group (P < 0.05), however, in follow-up no statistically significant difference was observed between the MVR and MVP group (P > 0.05). Follow-up mitral regurgitation grade was significantly improved in the MVR group compared with the MVP group (P < 0.05). The Kaplan-Meier survival estimates at 1, 3, and 5 years were simlar between MVP and MVR group. Logistic regression revealed poor survival was associated with old age(#75), preoperative renal insufficiency and low left ventricular ejection fraction (< 30%). Conclusion Mitral valve repair is the procedure of choice in the majority of patients having surgery for severe ischemic mitral regurgitation with left ventricular dysfunction. Early results of MVP treatment seem to be satisfactory, but several lines of data indicate that mitral valve repair provided less long-term benefit than mitral valve replacement in the LVD patients. PMID:21059216
[Plastic repair of tricuspid valve: Carpentier's ring annuloplasty versus De VEGA technique].
Charfeddine, Salma; Hammami, Rania; Triki, Faten; Abid, Leila; Hentati, Mourad; Frikha, Imed; Kammoun, Samir
2017-01-01
Tricuspid valve disease has been neglected for a long time by cardiologists and surgeons, but for some years now leakage of tricuspid valve has been demonstrated as a prognostic factor in the evolution of patients with left heart valve disease undergoing surgery. Several techniques for plastic repair of tricuspid valve have been developed and the published studies differ on the results of these techniques; we conducted this study to assess the results of plastic repair of tricuspid valve in a population of patients with a high prevalence of rheumatic disease and to compare Carpentier's ring annuloplasty techniques with DEVEGA plasty. We conducted a retrospective study of patients undergoing plastic repair of tricuspid valve in the Department of Cardiology at the Medicine University of Sfax over a period of 25 years. We compared the results from the Group 1 (Carpentier's ring annuloplasty) with Group 2 (DeVEGA plasty). 91 patients were included in our study, 45 patients in the Group 1 and 46 patients in the Group 2. Most patients had mean or severe TI (83%) before surgery, ring dilation was observed in 90% of patients with no significant difference between the two groups. Immediate results were comparable between the two techniques but during monitoring recurrent, at least mean, insufficiency was significantly more frequent in the DeVEGA plasty Group. The predictive factors for significant recurring long term TI were DeVEGA technique (OR=3.26[1.12-9.28]) in multivariate study and preoperative pulmonary artery systolic pressure (OR=1.06 (1.01-1.12)). Plastic repair of tricuspid valve using Carpentier's ring seems to guarantee better results than DeVEGA plasty. On the other hand, preoperative high PASP is predictive of recurrent leakage of tricuspid valve even after plasty; hence the importance of surgery in the treatment of patients at an early stage of the disease.
Minakata, Kenji; Tanaka, Shiro; Tamura, Nobushige; Yanagi, Shigeki; Ohkawa, Yohei; Okonogi, Shuichi; Kaneko, Tatsuo; Usui, Akihiko; Abe, Tomonobu; Shimamoto, Mitsuomi; Takahara, Yoshiharu; Yamanaka, Kazuo; Yaku, Hitoshi; Sakata, Ryuzo
2017-07-25
The aim of this study was to assess the long-term outcomes of aortic valve replacement (AVR) with either mechanical or bioprosthetic valves according to age at operation.Methods and Results:A total of 1,002 patients (527 mechanical valves and 475 bioprosthetic valves) undergoing first-time AVR were categorized according to age at operation: group Y, age <60 years; group M, age 60-69 years; and group O, age ≥70 years). Outcomes were compared on propensity score analysis (adjusted for 28 variables). Hazard ratio (HR) was calculated using the Cox regression model with adjustment for propensity score with bioprosthetic valve as a reference (HR=1). There were no significant differences in overall mortality between mechanical and bioprosthetic valves for all age groups. Valve-related mortality was significantly higher for mechanical valves in group O (HR, 2.53; P=0.02). Reoperation rate was significantly lower for mechanical valves in group Y (HR, 0.16; P<0.01) and group M (no events for mechanical valves). Although the rate of thromboembolic events was higher in mechanical valves in group Y (no events for tissue valves) and group M (HR, 9.05; P=0.03), there were no significant differences in bleeding events between all age groups. The type of prosthetic valve used in AVR does not significantly influence overall mortality.
A New, Highly Improved Two-Cycle Engine
NASA Technical Reports Server (NTRS)
Wiesen, Bernard
2008-01-01
The figure presents a cross-sectional view of a supercharged, variable-compression, two-cycle, internal-combustion engine that offers significant advantages over prior such engines. The improvements are embodied in a combination of design changes that contribute synergistically to improvements in performance and economy. Although the combination of design changes and the principles underlying them are complex, one of the main effects of the changes on the overall engine design is reduced (relative to prior two-cycle designs) mechanical complexity, which translates directly to reduced manufacturing cost and increased reliability. Other benefits include increases in the efficiency of both scavenging and supercharging. The improvements retain the simplicity and other advantages of two-cycle engines while affording increases in volumetric efficiency and performance across a wide range of operating conditions that, heretofore have been accessible to four-cycle engines but not to conventionally scavenged two-cycle ones, thereby increasing the range of usefulness of the two-cycle engine into all areas now dominated by the four-cycle engine. The design changes and benefits are too numerous to describe here in detail, but it is possible to summarize the major improvements: Reciprocating Shuttle Inlet Valve The entire reciprocating shuttle inlet valve and its operating gear is constructed as a single member. The shuttle valve is actuated in a lost-motion arrangement in which, at the ends of its stroke, projections on the shuttle valve come to rest against abutments at the ends of grooves in a piston skirt. This shuttle-valve design obviates the customary complex valve mechanism, actuated from an engine crankshaft or camshaft, yet it is effective with every type of two-cycle engine, from small high-speed single cylinder model engines, to large low-speed multiple cylinder engines.
Ouzounian, Maral; Rao, Vivek; Manlhiot, Cedric; Abraham, Nachum; David, Carolyn; Feindel, Christopher M; David, Tirone E
2016-10-25
Although aortic valve-sparing (AVS) operations are established alternatives to composite valve graft (CVG) procedures for patients with aortic root aneurysms, comparative long-term outcomes are lacking. This study sought to compare the results of patients undergoing AVS procedures with those undergoing CVG operations. From 1990 to 2010, a total of 616 patients age <70 years and without aortic stenosis underwent elective aortic root surgery (AVS, n = 253; CVG with a bioprosthesis [bio-CVG], n = 180; CVG with a mechanical prosthesis [m-CVG], n = 183). A propensity score was used as a covariate to adjust for unbalanced variables in group comparisons. Mean age was 46 ± 14 years, 83.3% were male, and mean follow-up was 9.8 ± 5.3 years. Patients undergoing AVS had higher rates of Marfan syndrome and lower rates of bicuspid aortic valve than those undergoing bio-CVG or m-CVG procedures. In-hospital mortality (0.3%) and stroke rate (1.3%) were similar among groups. After adjusting for clinical covariates, both bio-CVG and m-CVG procedures were associated with increased long-term major adverse valve-related events compared with patients undergoing AVS (hazard ratio [HR]: 3.4, p = 0.005; and HR: 5.2, p < 0.001, respectively). They were also associated with increased cardiac mortality (HR: 7.0, p = 0.001; and HR: 6.4, p = 0.003). Furthermore, bio-CVG procedures were associated with increased risk of reoperations (HR: 6.9; p = 0.003), and m-CVG procedures were associated with increased risk of anticoagulant-related hemorrhage (HR: 5.6; p = 0.008) compared with AVS procedures. This comparative study showed that AVS procedures were associated with reduced cardiac mortality and valve-related complications when compared with bio-CVG and m-CVG. AVS is the treatment of choice for young patients with aortic root aneurysm and normal or near-normal aortic cusps. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Patzelt, Johannes; Zhang, Yingying; Magunia, Harry; Jorbenadze, Rezo; Droppa, Michal; Ulrich, Miriam; Cai, Shanglang; Lausberg, Henning; Walker, Tobias; Wengenmayer, Tobias; Rosenberger, Peter; Schreieck, Juergen; Seizer, Peter; Gawaz, Meinrad; Langer, Harald F
2017-06-01
Successful percutaneous mitral valve repair (PMVR) in patients with severe mitral regurgitation (MR) causes changes in hemodynamics. Echocardiographic calculation of cardiac output (CO) has not been evaluated in the setting of PMVR, so far. Here we evaluated hemodynamics before and after PMVR with the MitraClip system using pulmonary artery catheterization, transthoracic (TTE) and transesophageal (TEE) echocardiography. 101 patients with severe MR not eligible for conventional surgery underwent PMVR. Hemodynamic parameters were determined during and after the intervention. We evaluated changes in CO and pulmonary artery systolic pressure before and after PMVR. CO was determined with invasive parameters using the Fick method (COi) and by a combination of TTE and TEE (COe). All patients had successful clip implantation, which was associated with increased COi (from 4.6±1.4l/min to 5.4±1.6l/min, p<0.001). Furthermore, pulmonary artery systolic pressure (PASP) showed a significant decrease after PMVR (47.6±16.1 before, 44.7±15.5mmHg after, p=0.01). In accordance with invasive measurements, COe increased significantly (COe from 4.3±1.7l/min to 4.8±1.7l/min, p=0.003). Comparing both methods to calculate CO, we observed good agreement between COi and COe using Bland Altman plots. CO increased significantly after PMVR as determined by echocardiography based and invasive calculation of hemodynamics during PMVR. COe shows good agreement with COi before and after the intervention and, thus, represents a potential non-invasive method to determine CO in patients with MR not accessible by conventional surgery. Copyright © 2017 Elsevier B.V. All rights reserved.
[Late complications following Björk-Shiley and St. Jude Medical heart valve replacement].
Horstkotte, D; Körfer, R; Budde, T; Haerten, K; Schulte, H D; Bircks, W; Loogen, F
1983-05-01
Valve-related complications after Björk-Shiley mitral (n = 475), aortic (n = 424), or mitral-aortic implantation (n = 119) were compared to complications after St. Jude mitral (n = 173), aortic (n = 152), and St. Jude mitral and aortic (n = 63) replacements. The 1,018 consecutive patients with Björk-Shiley valves had been operated upon between 1974 and 1982, those with St. Jude valves between 1978 and 1982. All patients were placed on anticoagulant therapy with phenprocoumon early after operation and no significant intergroup differences in the effectiveness of the anticoagulant therapy were found. At a comparable follow-up time of approximately 23 months, 24 major thromboembolic episodes were observed after Björk-Shiley mitral (BSM) and 3 after St. Jude mitral valve implantation (SJM), corresponding to a thromboembolic rate of 2.82/100 patient years with BSM and 0.93/100 patient years with SJM. After aortic valve replacements, 1.93 events in 100 patient years occurred after Björk-Shiley aortic (BSA) and 0.73 after St. Jude aortic implantation (SJA). In patients with double valve replacements, these rates were 3.2 (BSM + BSA) and 0.88 (SJM + SJA), respectively. The cerebral vessels were involved in 52% and the arteries of the extremities in 22% of these major events. Six Björk-Shiley prostheses had to be replaced because of valve thrombosis. The overall incidence of severe hemorrhagic complications was 2.94/100 patient years in BSM and 1.79 in SJM. After aortic valve replacement, we found rates of 1.80/100 patient years (BSA) and 2.57/100 patient years (SJA), respectively. Intravascular hemolysis no longer seems to be a significant clinical problem. However, indications of red cell damage after heart valve replacement were significantly greater in patients with perivalvular leakage, valve thrombosis, or dysfunction than in those with normally functioning prostheses. Reoperations were necessary because of valve thrombosis (0.46%), perivalvular leakage (2.2%), or prosthetic valve endocarditis with concomitant perivalvular regurgitation (0.46%). One valve had to be replaced because of fracture of the outlet strut of a BSM prosthesis. Hemorrhage due to the anticoagulant treatment was thus the most frequent complication, without significant intergroup differences, while thromboembolic complications were significantly more frequent after Björk-Shiley mitral, aortic, and double valve replacements than after St. Jude implantation. This may lead to the consideration of a change in the prophylaxis of thrombus formations with the St. Jude valve, especially in aortic valve replacements with sinus rhythm.
Single-site ventricular pacing via the coronary sinus in patients with tricuspid valve disease.
Noheria, Amit; van Zyl, Martin; Scott, Luis R; Srivathsan, Komandoor; Madhavan, Malini; Asirvatham, Samuel J; McLeod, Christopher J
2018-04-01
To evaluate coronary sinus single-site (CSSS) left ventricular pacing in adult patients with normal left ventricular ejection fraction (LVEF) when traditional right ventricular lead implantation is not feasible or is contraindicated. We performed a retrospective analysis of 23 patients with tricuspid valve surgery/disease who received a CSSS ventricular pacing lead to avoid crossing the tricuspid valve. Two matched control populations were obtained from patients receiving (i) conventional right ventricular single-site (RVSS) leads and (ii) coronary sinus leads for cardiac resynchronization therapy (CSCRT). Main outcomes of interest were lead stability, electrical lead parameters and change in LVEF during long-term follow-up. Successful CSSS pacing was accomplished in all 23 patients without any procedural complications. During the 5.3 ± 2.8-year follow-up 22/23 (95.7%) leads were functional with stable pacing and sensing parameters, and 1/23 (4.3%) was extracted for unrelated reasons. Compared to CSSS leads, the lead revision/abandonment was similar with RVSS leads (Hazard ratio (HR) 0.87, 95% confidence interval (CI) 0.03, 22.0), but was higher with CSCRT leads (HR 7.41, 95% CI 1.30, 139.0). There was no difference in change in LVEF between CSSS and RVSS groups (-2.4 ± 11.0 vs. 1.5 ± 12.8, P = 0.76), but LVEF improved in CSCRT group (11.2 ± 16.5%, P = 0.002). Fluoroscopy times were longer during implantation of CSSS compared to RVSS leads (25.6 ± 24.6 min vs. 12.3 ± 18.6 min, P = 0.049). In patients with normal LVEF, single-site ventricular pacing via the coronary sinus is a feasible, safe and reliable alternative to right ventricular pacing.
Schwencke, Carsten; Bijuklic, Klaudija; Ouarrak, Taoufik; Lubos, Edith; Schillinger, Wolfgang; Plicht, Björn; Eggebrecht, Holger; Baldus, Stephan; Schymik, Gerhard; Boekstegers, Peter; Hoffmann, Rainer; Senges, Jochen; Schofer, Joachim
2017-04-01
The use of the MitraClip system has gained widespread acceptance for the treatment of patients with mitral regurgitation (MR) who are not suitable for the conventional surgery. This study sought to investigate the early and 1-year outcome after MitraClip therapy of patients with MR and cardiac comorbidities. Outcomes through 12-month follow-up of patients (n = 528) who underwent MitraClip implantation were obtained from the German transcatheter mitral valve interventions (TRAMI) registry. The majority of these patients (n = 409, 77.5 %) also suffered from coronary artery disease (CAD). Patients with a dilated cardiomyopathy (DCM, n = 65, 12.3 %) or concomitant valvular aortic disease (AV, n = 54, 10.2 %) were less frequent. Although the prevalent pathogenesis was functional MR, patients with DCM had significantly more frequent a functional MR (96.9 %) compared to patients with CAD (74.9 %) or AV (62.5 %, p < 0.001). Technical success was achieved in 97.5 % of patients. Procedural echocardiograms demonstrated in the vast majority of patients a reduction from severe MR III to mild MR I with no difference between the groups (p = 0.83). The peri-procedural complication rate was very low. At 30-day and 12-month follow-up, the majority of patients were in NYHA functional class II or lower. The rate of death, stroke, and myocardial infarction (MACCE) was comparable in the three patient groups during 12-month follow-up (DCM 26.9 %, CAD 30.3 % and AV 27.5 %, p = 0.85). The MitraClip implantation is feasible and safe even in high-risk patients with MR and cardiac comorbidities.
Combined effects of hydrazine exposure and endurance testing on solenoid-actuated valve performance
NASA Technical Reports Server (NTRS)
Hagler, R., Jr.
1974-01-01
Results are presented from a test program which was conducted to assess the capability of various solenoid-actuated valve design concepts to provide performance characteristics commensurate with long-duration (ten-year) missions to explore the outer planets. The valves were installed in a hydrazine flow test setup and periodically cycled during a nine-month test period under test conditions comparable to anticipated mission operating conditions. In situ valve performance was periodically determined, and leakage was continuously monitored.
Globe stability during simulated vitrectomy with valved and non-valved trocar cannulas
Abulon, Dina Joy; Charles, Martin; Charles, Daniel E
2015-01-01
Purpose To compare the effects of valved and non-valved cannulas on intraocular pressure (IOP), fluid leakage, and vitreous incarceration during simulated vitrectomy. Methods Three-port pars plana incisions were generated in six rubber eyes using 23-, 25-, and 27-gauge valved and non-valved trocar cannulas. The models were filled with air and IOP was measured. Similar procedures were followed for 36 acrylic eyes filled with saline solution. Vitreous incarceration was analyzed in eleven rabbit and twelve porcine cadaver eyes. Results In the air-filled model, IOP loss was 89%–94% when two non-valved cannulas were unoccupied versus 1%–5% when two valved cannulas were unoccupied. In the fluid-filled model, with non-valved cannulas, IOP dropped while fluid leaked from the open ports. With two open ports, the IOP dropped to 20%–30% of set infusion pressure, regardless of infusion pressure and IOP compensation. The IOP was maintained in valved cannulas when one or two ports were left open, regardless of IOP compensation settings. There was no or minimal fluid leakage through open ports at any infusion pressure. Direct microscopic analysis of rabbit eyes showed that vitreous incarceration was significantly greater with 23-gauge non-valved than valved cannulas (P<0.005), and endoscopy of porcine eyes showed that vitreous incarceration was significantly greater with 23-gauge (P<0.05) and 27-gauge (P<0.05) non-valved cannulas. External observation of rabbit eyes showed vitreous prolapse through non-valved, but not valved, cannulas. Conclusion Valved cannulas surpassed non-valved cannulas in maintaining IOP, preventing fluid leakage, and reducing vitreous incarceration during simulated vitrectomy. PMID:26445520
Ailawadi, Gorav; LaPar, Damien J; Speir, Alan M; Ghanta, Ravi K; Yarboro, Leora T; Crosby, Ivan K; Lim, D Scott; Quader, Mohammed A; Rich, Jeffrey B
2016-01-01
The Placement of Aortic Transcatheter Valve (PARTNER) trial suggested an economic advantage for transcatheter aortic valve replacement (TAVR) for high-risk patients. The purpose of this study was to evaluate the cost effectiveness of TAVR in the "real world" by comparing TAVR with surgical aortic valve replacement (SAVR) in intermediate-risk and high-risk patients. A multiinstitutional database of The Society of Thoracic Surgeons (STS) (2011 to 2013) linked with estimated cost data was evaluated for isolated TAVR and SAVR operations (n = 5,578). TAVR-treated patients (n = 340) were 1:1 propensity matched with SAVR-treated patients (n = 340). Patients undergoing SAVR were further stratified into intermediate-risk (SAVR-IR: predicted risk of mortality [PROM] 4% to 8%) and high-risk (SAVR-HR: PROM >8%) cohorts. Median STS PROM for TAVR was 6.32% compared with 6.30% for SAVR (SAVR-IR 4.6% and SAVR-HR 12.4%). A transfemoral TAVR approach was most common (61%). Mortality was higher for TAVR (10%) compared with SAVR (6%, p < 0.047), whereas the SAVR group accrued higher major morbidity (27% vs 14%, p < 0.001) and longer postoperative hospital duration (7 days vs 6 days, p < 0.001). Importantly, TAVR incurred twice the median total costs compared with SAVR ($69,921 vs $33,598, p < 0.001). The increased cost of TAVR was largely driven by the cost of the valve (all p < 0.001). Intermediate-risk patients undergoing SAVR demonstrated the most exaggerated cost savings versus TAVR. TAVR was associated with greater total costs and mortality compared with SAVR in intermediate-risk and high-risk patients while conferring lower major morbidity and improved resource use. Increased cost of TAVR appears largely related to the cost of the valve. Until the price of TAVR valves decreases, these data suggest that TAVR may not provide the most cost-effective strategy, particularly for intermediate-risk patients. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Luong, Quang Minh; Shang, Lei; Ang, Marcus; Kong, Jen Fong; Peng, Yan; Wong, Tina T; Venkatraman, Subbu S
2014-02-01
Glaucoma drainage device (GDD) implantation is an effective method of lowering the intraocular pressure (IOP). Commonly used GDDs can be classified into nonvalved and valved. Although a stable IOP is critical, currently available devices often cause extreme IOP fluctuations: nonvalved GDDs suffer from a risk of hypotony (IOP<5 mmHg), whereas valved GDDs have a higher risk ocular hypertensive (IOP>22 mmHg). It is hypothesized that a GDD with a valve designed to open around the time of onset of the hypertensive phase, would minimize IOP fluctuation. Accordingly, a valve fabricated from a biodegradable polymer poly(L-lactide-co-ϵ-caprolactone) (PLC 70/30) is evaluated in vitro and in vivo. The pressure response is compared with its non-degradable counterpart in in vitro studies of IOP. It is also established that in vitro, the biodegradability of the valve is programmed to occur over 12 weeks. In vivo, a steady and low IOP is achieved with the biodegradable valve and the hypertensive phase is significantly attenuated compared with the commercial device. Fibrotic encapsulation of the device is also minimized with the biodegradable valve in vivo. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Behr, Luc; Chetboul, Valérie; Sampedrano, Carolina Carlos; Vassiliki, Gouni; Pouchelon, Jean-Louis; Laborde, François; Borenstein, Nicolas
2007-04-01
To describe an open, beating heart surgical technique and use of a bovine pericardial prosthetic valve for mitral valve replacement (MVR) in the dog. Clinical case report. Male Bull Terrier (17-month-old, 26 kg) with mitral valve dysplasia and severe regurgitation. A bovine pericardial bioprosthesis was used to replace the mitral valve using an open beating heart surgical technique and cardiopulmonary bypass. Successful MVR was achieved using a beating heart technique. Mitral regurgitation resolved and cardiac performances improved (left ventricular end-diastolic diameter decreased from 57.6 to 48.7 mm, and left atrium/aorta ratio returned to almost normal, from 1.62 to 1.19). Cardiopulmonary by-pass time and total surgical duration were decreased compared with standard cardioplegic techniques. Surgical recovery was uneventful and on echocardiography 6 months later valve function was excellent. Considering the technique advantages (no cardiac arrest, ischemic reperfusion injury, and hypothermia, or the need for aortic dissection and cannulation for administration of cardioplegic solution), short-term mortality and morbidity may be reduced compared with standard cardioplegic techniques. Based on experience in this dog, beating heart mitral valvular replacement is a seemingly safe and viable option for the dog and bovine pericardial prosthesis may provide better long-term survival than mechanical prostheses.
Programmable shunt valves for the treatment of hydrocephalus: a systematic review.
Xu, H; Wang, Z X; Liu, F; Tan, G W; Zhu, H W; Chen, D H
2013-09-01
To evaluate the clinical effectiveness of programmable valves compared with non-programmable valves of hydrocephalus. In this paper, the authors report a systematic review and meta-analysis of complications and revision rate for programmable valves and non-programmable implantation. Randomized or non-randomized controlled trials of hydrocephalus treated by programmable and non-programmable valves were considered for inclusion. Seven published reports of eligible studies involving 1702 participants meet the inclusion criteria. Compared with non-programmable, programmable valves had no significant difference in catheter-related complications [RR = 0.88, 95%CI (0.66,1.19), p = 0.10] and infection rate [RR = 1.25, 95%CI (0.92,1.69), p = 1.00]. There were significant differences in overall complications [RR = 0.80, 95%CI (0.67,0.96), p < 0.01], over-drainage or under-drainage complications [RR = 0.44, 95%CI (0.31,0.63), p < 0.01] and revision rate [RR = 0.56, 95%CI (0.45,0.69), p < 0.01] in favor of programmable valves. Although the studies seem to demonstrate a small advantage for the programmable shunts, the probable bias and the difficulties in patient selection are too important to make a general conclusion. Copyright © 2013. Published by Elsevier Ltd.
Mourino-Alvarez, Laura; Iloro, Ibon; de la Cuesta, Fernando; Azkargorta, Mikel; Sastre-Oliva, Tamara; Escobes, Iraide; Lopez-Almodovar, Luis F; Sanchez, Pedro L; Urreta, Harkaitz; Fernandez-Aviles, Francisco; Pinto, Angel; Padial, Luis R; Akerström, Finn; Elortza, Felix; Barderas, Maria G
2016-06-03
Aortic stenosis (AS) is the most common form of valve disease. Once symptoms develop, there is an inexorable deterioration with a poor prognosis; currently there are no therapies capable of modifying disease progression, and aortic valve replacement is the only available treatment. Our goal is to study the progression of calcification by matrix-assisted laser desorption ionization imaging mass spectrometry (MALDI-IMS) and get new insights at molecular level that could help in the understanding of this disease. In this work, we analyzed consecutive slices from aortic valve tissue by MALDI-IMS, to establish the spatial distribution of proteins and peptides directly from the surface of the histological sections. The analysis showed different structures corresponding to regions observed in conventional histology, including large calcification areas and zones rich in collagen and elastic fibers. Peptide extraction from the tissue, followed by liquid chromatography mass spectrometry analysis, provided the identification of collagen VI α-3 and NDRG2 proteins which correlated with the masses obtained by MALDI-IMS and were confirmed by immunohistochemistry. These results highlighted the molecular mechanism implied in AS using MALDI-IMS, a novel technique never used before in this pathology. In addition, we can define specific regions proving a complementary resolution of the molecular histology.
Gössl, Mario; Johnson, Jonathan N; Hagler, Donald J
2014-04-01
We present the case of a 36-year-old woman with increasing shortness of breath, a new 3/4 diastolic murmur, and a complex history of LV outflow tract obstruction. She has undergone multiple surgeries including the replacement of her old LV apex to ascending aorta conduit with a 20-mm Gore-Tex tube graft, addition of a 24-mm homograft sutured between the conduit and the LV apex, and insertion of a 21-mm Freestyle porcine valve conduit between the Gore-Tex tube graft and allograft at age 23. The current assessment showed a failing Freestyle conduit prosthesis leading to left heart decompensation. Due to substantial surgical risk, the patient underwent successful implantation of a Melody valve into the Gore-Tex tube and exclusion of the failing Freestyle bioprosthesis with a NuMed CP stent in a hybrid procedure. The case nicely illustrates the collaborative potential of cardiovascular surgeons and interventional cardiologists in the new arena of a hybrid operating room. Complex hybrid procedures like the current one, especially those including percutaneous placements of valves, offer therapeutic options for patients that are otherwise too high risk for conventional open heart surgery. Copyright © 2013 Wiley Periodicals, Inc.
A Lifting Ball Valve for cryogenic fluid applications
NASA Astrophysics Data System (ADS)
Cardin, Joseph M.; Reinicke, Robert H.; Bruneau, Stephen D.
1993-11-01
Marotta Scientific Controls, Inc. has designed a Lifting Ball Valve (LBV) capable of both flow modulation and tight shutoff for cryogenic and other applications. The LBV features a thin-walled visor valving element that lifts off the seal with near axial motion before rotating completely out of the flow path. This is accomplished with a simple, robust mechanism that minimizes cost and weight. Conventional spherical rotating seats ar plagued by leakage due to 'scuffing' as the seal and seat slide against one another while opening. Cryogenic valves, which typically utilize plastic seals, are particularly susceptible to this type of damage. The seat in the LBV lifts off the seal without 'scuffing' making it immune to this failure mode. In addition, the LBV lifting mechanism is capable of applying the very high seating loads required to seal at cryogenic temperatures. These features make the LBV ideally suited for cryogenic valve applications. Another major feature of the LBV is the fact that the visor rotates completely out of the flow path. This allows for a smaller, lighter valve for a given flow capacity, especially for line sizes above one inch. The LBV is operated by a highly integrated 'wetted' DC brushless motor. The motor rotor is 'wetted' ion that it is immersed in the fluid. To ensure compatibility, the motor rotor is encased in a thin-walled CRES weldment. The motor stator is outside the fluid containment weldment and therefore is not in direct contact with the fluid. To preclude the potential for external leakage there are no static or dynamic seals or bellows across the pressure boundary. The power required to do the work of operating the valving mechanism is transmitted across the pressure boundary by electromagnetic interaction between the motor rotor and the stator. Commutation of the motor is accomplished using the output of a special 'wetted' resolver. This paper describes the design, operation, and element testing of the LBV.
Lee, Ji Won; Kim, Chang Won; Lee, Geewon; Lee, Han Cheol; Kim, Sang-Pil; Choi, Bum Sung; Jeong, Yeon Joo
2018-02-01
Background Using the hybrid electrocardiogram (ECG)-gated computed tomography (CT) technique, assessment of entire aorta, coronary arteries, and aortic valve can be possible using single-bolus contrast administration within a single acquisition. Purpose To compare the image quality of hybrid ECG-gated and non-gated CT angiography of the aorta and evaluate the effect of a motion correction algorithm (MCA) on coronary artery image quality in a hybrid ECG-gated aorta CT group. Material and Methods In total, 104 patients (76 men; mean age = 65.8 years) prospectively randomized into two groups (Group 1 = hybrid ECG-gated CT; Group 2 = non-gated CT) underwent wide-detector array aorta CT. Image quality, assessed using a four-point scale, was compared between the groups. Coronary artery image quality was compared between the conventional reconstruction and motion correction reconstruction subgroups in Group 1. Results Group 1 showed significant advantages over Group 2 in aortic wall, cardiac chamber, aortic valve, coronary ostia, and main coronary arteries image quality (all P < 0.001). All Group 1 patients had diagnostic image quality of the aortic wall and left ostium. The MCA significantly improved the image quality of the three main coronary arteries ( P < 0.05). Moreover, per-vessel interpretability improved from 92.3% to 97.1% with the MCA ( P = 0.013). Conclusion Hybrid ECG-gated CT significantly improved the heart and aortic wall image quality and the MCA can further improve the image quality and interpretability of coronary arteries.
Echocardiographic Assessment of Heart Valve Prostheses
Sordelli, Chiara; Severino, Sergio; Ascione, Luigi; Coppolino, Pasquale; Caso, Pio
2014-01-01
Patients submitted to valve replacement with mechanical or biological prosthesis, may present symptoms related either to valvular malfunction or ventricular dysfunction from other causes. Because a clinical examination is not sufficient to evaluate a prosthetic valve, several diagnostic methods have been proposed to assess the functional status of a prosthetic valve. This review provides an overview of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. Compared to native valves, echocardiographic evaluation of prosthetic valves is certainly more complex, both for the examination and the interpretation. Echocardiography also allows discriminating between intra- and/or peri-prosthetic regurgitation, present in the majority of mechanical valves. Transthoracic echocardiography (TTE) requires different angles of the probe with unconventional views. Transesophageal echocardiography (TEE) is the method of choice in presence of technical difficulties. Three-dimensional (3D)-TEE seems to be superior to 2D-TEE, especially in the assessment of paravalvular leak regurgitation (PVL) that it provides improved localization and analysis of the PVL size and shape. PMID:28465917
Kutryb-Zajac, Barbara; Yuen, Ada H Y; Khalpey, Zain; Zukowska, Paulina; Slominska, Ewa M; Taylor, Patricia M; Goldstein, Steven; Heacox, Albert E; Lavitrano, Marialuisa; Chester, Adrian H; Yacoub, Magdi H; Smolenski, Ryszard T
2016-04-01
Extracellular nucleotide metabolism controls thrombosis and inflammation and may affect degeneration and calcification of aortic valve prostheses. We evaluated the effect of different decellularization strategies on enzyme activities involved in extracellular nucleotide metabolism. Porcine valves were tested intact or decellularized either by detergent treatment or hypotonic lysis and nuclease digestion. The rates of ATP hydrolysis, AMP hydrolysis, and adenosine deamination were estimated by incubation of aorta or valve leaflet sections with substrates followed by HPLC analysis. We demonstrated relatively high activities of ecto-enzymes on porcine valve as compared to the aortic wall. Hypotonic lysis/nuclease digestion preserved >80 % of ATP and AMP hydrolytic activity but reduced adenosine deamination to <10 %. Detergent decellularization completely removed (<5 %) all these activities. These results demonstrate high intensity of extracellular nucleotide metabolism on valve surface and indicate that various valve decellularization techniques differently affect ecto-enzyme activities that could be important in the development of improved valve prostheses.
Micro system comprising 96 micro valves on a titer plate
NASA Astrophysics Data System (ADS)
Krabbe, S.; Flitsch, D.; Büchs, J.; Schomburg, W. K.
2016-10-01
A system of 96 micro valves has been developed and mounted on top of a 48-well micro titer plate providing two valves for each well controlling its air inlet and outlet. Testing of the valve system showed that all valves are working and are opened and closed reliably. A pneumatic system is switching inlet and outlet valves independently of each other. The geometry of the feed channels ensures an equal air flow through all wells, when the valves are open. Between the micro valves, one optical fibre was inserted through the lid of each well allowing measuring the oxygen partial pressure in the enclosed air volume by fluorescence sensor spots. Escherichia coli bacteria were grown inside the wells and their metabolism was observed by the oxygen partial pressure change due to respiration. In all 48 wells, the same oxygen transfer rate was observed within an averaged standard deviation of 1 mmol/L/h. The oxygen transfer rate differences compared to a macroscopic standard shake flask system were overall compatible within their uncertainties.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1982-04-30
The work done to extend the existing drain-down valve technology to provide passive drain-down freeze protection for thermosyphon-based solar water heaters is described. The basic design of the existing valve model is that of a spool valve, employing a cylindrical spool which moves axially in a mating cartridge to open and close o-rings at the two operating extremes (drain and operate) to perform the valving function. Three passive actuators to drive the basic valving mechanism were designed, fabricated, and tested. Two piping configurations used to integrate the spool valve with the thermosyphon system are described, as are the passive actuators.more » The three actuator designs are: photovoltaic driven, refrigerant-based bellows, and heat motor cable-drive designs. Costs are compared for the alternative actuator designs, and operating characteristics were examined for the thermosyphon system, including field tests. The market for the valve for thermosyphon systems is then assessed. (LEW)« less
Hahs, Charles A.; Burbage, Charles H.
1984-01-01
The invention is a pneumatically operated valve assembly for simultaneously (1) closing gas-transfer lines connected to a gas centrifuge or the like and (2) establishing a recycle path between two of the lines so closed. The valve assembly is especially designed to be compact, fast-acting, reliable, and comparatively inexpensive. It provides large reductions in capital costs for gas-centrifuge cascades.
Three-dimentional simulation of flow-induced platelet activation in artificial heart valves
NASA Astrophysics Data System (ADS)
Hedayat, Mohammadali; Asgharzadeh, Hafez; Borazjani, Iman
2015-11-01
Since the advent of heart valve, several valve types such as mechanical and bio-prosthetic valves have been designed. Mechanical Heart Valves (MHV) are durable but suffer from thromboembolic complications that caused by shear-induced platelet activation near the valve region. Bio-prosthetic Heart Valves (BHV) are known for better hemodynamics. However, they usually have a short average life time. Realistic simulations of heart valves in combination with platelet activation models can lead to a better understanding of the potential risk of thrombus formation in such devices. In this study, an Eulerian approach is developed to calculate the platelet activation in three-dimensional simulations of flow through MHV and BHV using a parallel overset-curvilinear immersed boundary technique. A curvilinear body-fitted grid is used for the flow simulation through the anatomic aorta, while the sharp-interface immersed boundary method is used for simulation of the Left Ventricle (LV) with prescribed motion. In addition, dynamics of valves were calculated numerically using under-relaxed strong-coupling algorithm. Finally, the platelet activation results for BMV and MHV are compared with each other.
Thrombogenic potential of transcatheter aortic valve implantation with trivial paravalvular leakage
Siegel, Rolland
2014-01-01
Background Significant paravalvular leakage after transcatheter aortic valve implantation (TAVI) correlates with increased morbidity and mortality, but adverse consequences of trivial paravalvular leakage have stimulated few investigations. Using a unique method distinctly different from other diagnostic approaches, we previously reported elevated backflow velocities of short duration (transients) in mechanical valve closure. In this study, similar transients were found in a transcatheter valve paravalvular leakage avatar. Methods Paravalvular leakage rate (zero to 58 mL/second) and aortic valve incompetence (volumetric back flow/forward flow; zero to 32%) were made adjustable using a mock transcatheter aortic valve device and tested in quasi-steady and pulsatile flow test systems. Projected dynamic valve area (PDVA) from the back illuminated mock transcatheter aortic valve device was measured and regional backflow velocities were derived by dividing volumetric flow rate by the PDVA over the open and closing valve phase and the total closed valve area derived from backflow leakage. Results Aortic incompetence from 1-32% generated negative backflow transients from 8 to 267 meters/second, a range not dissimilar to that measured in mechanical valves with zero paravalvular leakage. Optimal paravalvular leakage was identified; not too small generating high backflow transients, not too large considering volume overload and cardiac energy loss caused by defective valve behavior and fluid motion. Conclusions Thrombogenic potential of transcatheter aortic valves with trivial aortic incompetence and high magnitude regional backflow velocity transients was comparable to mechanical valves. This may have relevance to stroke rate, asymptomatic microembolic episodes and indications for anticoagulation therapy after transcatheter valve insertion. PMID:25333018
Fault detection and diagnosis of diesel engine valve trains
NASA Astrophysics Data System (ADS)
Flett, Justin; Bone, Gary M.
2016-05-01
This paper presents the development of a fault detection and diagnosis (FDD) system for use with a diesel internal combustion engine (ICE) valve train. A novel feature is generated for each of the valve closing and combustion impacts. Deformed valve spring faults and abnormal valve clearance faults were seeded on a diesel engine instrumented with one accelerometer. Five classification methods were implemented experimentally and compared. The FDD system using the Naïve-Bayes classification method produced the best overall performance, with a lowest detection accuracy (DA) of 99.95% and a lowest classification accuracy (CA) of 99.95% for the spring faults occurring on individual valves. The lowest DA and CA values for multiple faults occurring simultaneously were 99.95% and 92.45%, respectively. The DA and CA results demonstrate the accuracy of our FDD system for diesel ICE valve train fault scenarios not previously addressed in the literature.
Measurement and reconstruction of the leaflet geometry for a pericardial artificial heart valve.
Jiang, Hongjun; Campbell, Gord; Xi, Fengfeng
2005-03-01
This paper describes the measurement and reconstruction of the leaflet geometry for a pericardial heart valve. Tasks involved include mapping the leaflet geometries by laser digitizing and reconstructing the 3D freeform leaflet surface based on a laser scanned profile. The challenge is to design a prosthetic valve that maximizes the benefits offered to the recipient as compared to the normally operating naturally-occurring valve. This research was prompted by the fact that artificial heart valve bioprostheses do not provide long life durability comparable to the natural heart valve, together with the anticipated benefits associated with defining the valve geometries, especially the leaflet geometries for the bioprosthetic and human valves, in order to create a replicate valve fabricated from synthetic materials. Our method applies the concept of reverse engineering in order to reconstruct the freeform surface geometry. A Brown & Shape coordinate measuring machine (CMM) equipped with a HyMARC laser-digitizing system was used to measure the leaflet profiles of a Baxter Carpentier-Edwards pericardial heart valve. The computer software, Polyworks was used to pre-process the raw data obtained from the scanning, which included merging images, eliminating duplicate points, and adding interpolated points. Three methods, creating a mesh model from cloud points, creating a freeform surface from cloud points, and generating a freeform surface by B-splines are presented in this paper to reconstruct the freeform leaflet surface. The mesh model created using Polyworks can be used for rapid prototyping and visualization. To fit a freeform surface to cloud points is straightforward but the rendering of a smooth surface is usually unpredictable. A surface fitted by a group of B-splines fitted to cloud points was found to be much smoother. This method offers the possibility of manually adjusting the surface curvature, locally. However, the process is complex and requires additional manipulation. Finally, this paper presents a reverse engineered design for the pericardial heart valve which contains three identical leaflets with reconstructed geometry.
NASA Astrophysics Data System (ADS)
Wijaya Sunu, Putu; Made Rasta, I.; Anakottapary, Daud Simon; Made Suarta, I.; Cipta Santosa, I. D. M.
2018-01-01
The aims of this study to compares the performance characteristics of a water chiller air conditioning simulation equipped with thermostatic expansion valve (TEV) with those of a capillary tube. Water chiller system filled with the same charge of refrigerant. Comparative analyses were performed based on coefficient of performance (COP) and performance parameter of the refrigeration system, carried out at medium cooling load level with the ambient temperature of 29-31°C, constant compressor speed and fixed chilled water volume flowrate at 15 lpm. It was shown that the TEV system showed better energy consumption compared to that of capillary tube. From the coefficient of performance perspective, the thermostatic expansion valve system showed higher COP (± 21.4%) compared to that of capillary tube system.
Mitral valve prolapse and hyperthyroidism: effect of patient selection.
Zullo, M A; Devereux, R B; Kramer-Fox, R; Lutas, E M; Brown, W T
1985-11-01
Patients with mitral valve prolapse and hyperthyroidism have common symptoms; the most outstanding symptom is palpitation. To determine whether or not common symptoms contributed to the reported association of these conditions, we evaluated 220 patients with symptomatic mitral valve prolapse and 216 first-degree relatives in 72 families; 65 relatives with mitral valve prolapse and 151 relatives without mitral valve prolapse, all greater than or equal to 16 years of age. Thirty subjects, aged 49 +/- 13 years (p less than 0.025 vs entire study group), had thyroid disease (23 subjects had definite thyroid disease, seven subjects had probable); 27 of 30 subjects with thyroid disease (90%) were female (p less than 0.005). The age- and sex-adjusted prevalence of hyperthyroidism was significantly higher in probands with mitral valve prolapse than in family members without mitral valve prolapse (3.5% vs 0%, p = 0.03), while an intermediate prevalence of hyperthyroidism (2.2%) was observed in family members with mitral valve prolapse. Thus, the prevalence of hyperthyroidism is increased among symptomatic patients with mitral valve prolapse as compared to family members without mitral valve prolapse, but the prevalence of thyroid conditions is similar among family members with or without this condition. These findings are explained by the effect of common symptoms on clinical detection of both mitral valve prolapse and hyperthyroidism.
Trabeculectomy versus Ahmed Glaucoma Valve implantation in neovascular glaucoma
Shen, Christopher C; Salim, Sarwat; Du, Haiming; Netland, Peter A
2011-01-01
Purpose: To compare surgical outcomes in neovascular glaucoma patients who underwent trabeculectomy with mitomycin C versus Ahmed Glaucoma Valve implantation. Patients and methods: This was a retrospective comparative case series. We reviewed 40 eyes of 39 patients with underlying diagnosis of neovascular glaucoma, divided into two groups: Ahmed Glaucoma Valve (N = 20) and trabeculectomy with mitomycin C (N = 20). Surgical success was defined as 6 mm Hg ≤ intraocular pressure ≤21 mm Hg, with or without the use of glaucoma medications, with no further glaucoma surgery, and light perception or better vision. Early postoperative hypotony was defined as intraocular pressure <5 mm Hg during the first postoperative week. Results: The average follow-up was 31 months (range 6–87 months) for the Ahmed Glaucoma Valve group and 25 months (6–77 months) for the trabeculectomy group. Although the mean number of postoperative intraocular pressure-lowering medications was significantly higher in the trabeculectomy group compared with the Ahmed Glaucoma Valve group at 3 and 6 month time points, there was no statistically significant difference at any other time point. There was no statistically significant difference between both groups in postoperative visual acuity and intraocular pressure. Success was 70% and 65% at 1 year and 60% and 55% at 2 years after Ahmed Glaucoma Valve and trabeculectomy, respectively. Kaplan–Meier survival curve analysis showed no significant difference in success between the two groups (P = 0.815). Hyphema was the most common complication in both groups. Conclusion: We found similar results after trabeculectomy with mitomycin C and Ahmed Glaucoma Valve implantation in eyes with neovascular glaucoma. PMID:21468334
Comparing Usual Care With a Warfarin Initiation Protocol After Mechanical Heart Valve Replacement.
Roberts, Gregory; Razooqi, Rasha; Quinn, Stephen
2017-03-01
The immediate postoperative warfarin sensitivity for patients receiving heart valve prostheses is increased. Established warfarin initiation protocols may lack clinical applicability, resulting in dosing based on clinical judgment. To compare current practice for warfarin initiation with a known warfarin initiation protocol, with doses proportionally reduced to account for the increased postoperative sensitivity. We compared the Mechanical Heart Valve Warfarin Initiation Protocol (Protocol group) with current practice (clinical judgment-Empirical group) for patients receiving mechanical heart valves in an observational before-and-after format. End points were the time to achieve a stable therapeutic international normalized ratio (INR), doses held in the first 6 days, and overanticoagulation in the first 6 days. The Protocol group (n = 37) achieved a stable INR more rapidly than the Empirical group (n = 77; median times 5.1 and 8.7 days, respectively; P = 0.002). Multivariable analysis indicated that the Protocol group (hazard ratio [HR] = 2.22; P = 0.005) and men (HR = 1.76; P = 0.043) more rapidly achieved a stable therapeutic INR. Age, serum albumin, amiodarone, presence of severe heart failure, and surgery type had no impact. Protocol patients had fewer doses held (1.1% vs 10.1%, P < 0.001) and no difference in overanticoagulation (2.7% vs 9.1%, P = 0.27). The Mechanical Heart Valve Warfarin Initiation Protocol provided a reliable approach to initiating warfarin in patients receiving mechanical aortic or mitral valves.
El Sayed, Y; Awadein, A
2013-01-01
Purpose To compare the results of silicone and polypropylene Ahmed glaucoma valves (AGV) implanted during the first 10 years of life. Methods A prospective study was performed on 50 eyes of 33 patients with paediatric glaucoma. Eyes were matched to either polypropylene or silicone AGV. In eyes with bilateral glaucoma, one eye was implanted with polypropylene and the other eye was implanted with silicone AGV. Results Fifty eyes of 33 children were reviewed. Twenty five eyes received a polypropylene valve, and 25 eyes received a silicone valve. Eyes implanted with silicone valves achieved a significantly lower intraocular pressure (IOP) compared with the polypropylene group at 6 months, 1 year, and 2 years postoperatively. The average survival time was significantly longer (P=0.001 by the log-rank test) for the silicone group than for the polypropylene group and the cumulative probability of survival by the log-rank test at the end of the second year was 80% (SE: 8.0, 95% confidence interval (CI): 64–96%) in the silicone group and 56% (SE: 9.8, 95% CI: 40–90%) in the polypropylene group. The difference in the number of postoperative interventions and complications between both groups was statistically insignificant. Conclusion Silicone AGVs can achieve better IOP control, and longer survival with less antiglaucoma drops compared with polypropylene valves in children younger than 10 years. PMID:23579403
Aortic valve repair leads to a low incidence of valve-related complications.
Aicher, Diana; Fries, Roland; Rodionycheva, Svetlana; Schmidt, Kathrin; Langer, Frank; Schäfers, Hans-Joachim
2010-01-01
Aortic valve replacement for aortic regurgitation (AR) has been established as a standard treatment but implies prosthesis-related complications. Aortic valve repair is an alternative approach, but its mid- to long-term results still need to be defined. Over a 12-year period, 640 patients underwent aortic valve repair for regurgitation of a unicuspid (n=21), bicuspid (n=205), tricuspid (n=411) or quadricuspid (n=3) aortic valve. The mechanism of regurgitation involved prolapse (n=469) or retraction (n=20) of the cusps, and dilatation of the root (n=323) or combined pathologies. Treatment consisted of cusp repair (n=529), root repair (n=323) or a combination of both (n=208). The patients were followed clinically and echocardiographically; follow-up was complete in 98.5% (cumulative follow-up: 3035 patient years). Hospital mortality was 3.4% in the total patient cohort and 0.8% for isolated aortic valve repair. The incidences of thrombo-embolism (0.2% per patient per year) and endocarditis (0.16%per patient per year) were low. Freedom from re-operation at 5 and 10 years was 88% and 81% in bicuspid and 97% and 93% in tricuspid aortic valves (p=0.0013). At re-operation, 13 out of 36 valves could be re-repaired. Freedom from valve replacement was 95% and 90% in bicuspid and 97% and 94% in tricuspid aortic valves (p=0.36). Freedom from all valve-related complications at 10 years was 88%. Reconstructive surgery of the aortic valve is feasible with low mortality in many individuals with aortic regurgitation. Freedom from valve-related complications after valve repair seems superior compared to available data on standard aortic valve replacement. Copyright 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Bae, Kunho; Suh, Wool; Kee, Changwon
2012-08-01
To compare the histopathologic and morphologic findings of encapsulated blebs following Ahmed glaucoma valve implantation and primary standard trabeculectomy with mitomycin-C. We reviewed the records of patients with otherwise uncontrollable glaucoma who had undergone Ahmed glaucoma valve implantation or trabeculectomy with mitomycin-C. Five eyes that underwent Ahmed valve implantation and three eyes that underwent trabeculectomy needed surgical revision of the initial surgery due to encapsulated bleb development with total loss of function. The surgically removed encapsulated blebs were analyzed macroscopically and microscopically. Removal of the encapsulated bleb was performed at a mean follow-up time of 26.6 ± 19.4 weeks in the Ahmed valve implantation group and 12.0 ± 11.4 weeks in the trabeculectomy group. The fibrotic wall of the encapsulated blebs had an overall thickness of 2.48 ± 0.42 mm in the Ahmed valve implantation group and 1.62 ± 0.37 mm in the trabeculectomy group. Macroscopically, the coconut flesh-like smooth surface was split into two layers, and the wall of the capsule was thicker in the Ahmed valve implantation group than in the trabeculectomy group. Histopathologically, the fibrotic capsule was composed of an inner fibrodegenerative layer and an outer fibrovascular layer, and there were no histopathological differences between the two groups. The fibrotic capsule wall was thicker in the Ahmed valve group, but there were no differences in histological findings between the two groups.
Hybrid textile heart valve prosthesis: preliminary in vitro evaluation.
Vaesken, Antoine; Pidancier, Christian; Chakfe, Nabil; Heim, Frederic
2016-09-22
Transcatheter aortic valve implantation (TAVI) is nowadays a popular alternative technique to surgical valve replacement for critical patients. Biological valve tissue has been used in these devices for over a decade now with over 100,000 implantations. However, material degradations due to crimping for catheter insertion purpose have been reported, and with only 6-year follow-up, no information is available about the long-term durability of biological tissue. Moreover, expensive biological tissue harvesting and chemical treatment procedures tend to promote the development of synthetic valve leaflet materials. Textile polyester (PET) material is characterized by outstanding folding and strength properties combined with proven biocompatibility and could therefore be considered as a candidate to replace biological valve leaflets in TAVI devices. Nevertheless, the material should be preferentially partly elastic in order to limit water hammer effects at valve closing time and prevent exaggerated stress from occurring into the stent and the valve. The purpose of the present work is to study in vitro the mechanical as well as the hydrodynamic behavior of a hybrid elastic textile valve device combining non-deformable PET yarn and elastic polyurethane (PU) yarn. The hybrid valve properties are compared with those of a non-elastic textile valve. Testing results show improved hydrodynamic properties with the elastic construction. However, under fatigue conditions, the interaction between PU and PET yarns tends to limit the valve durability.
Trans-apical aortic valve implantation using a new self-expandable bioprosthesis: initial outcomes.
Kempfert, Jörg; Rastan, Ardawan J; Beyersdorf, Friedhelm; Schönburg, Markus; Schuler, Gerhard; Sorg, Stefan; Mohr, Friedrich-W; Walther, Thomas
2011-11-01
Trans-apical aortic valve implantation (TA-AVI) has evolved into a standard approach for high-risk, elderly patients using the balloon-expandable Edwards SAPIEN™ prosthesis. As an alternative device, a self-expanding sub-coronary trans-apical bioprosthesis was evaluated. The Symetis Acurate™ trans-catheter heart valve is composed of a porcine biologic valve attached to a self-expandable nitinol stent. It allows for anatomical orientation, and facilitates intuitive implantation providing tactile feedback. Three valves sizes were available to treat patients with an annular diameter between 21 and 27mm. Since November 2009, a total of 40 patients have been treated at three sites. Patient age was 82.8±4 years, 60% were female, logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 21.5±10.9% and Society of Thoracic Surgeons (STS) Score was 9.0±4.6%. All implants were delivered successfully in the intra-annular and sub-coronary position off pump. One patient was converted to conventional surgery due to coronary impingement; post-dilatation was performed in 45% of patients; and two patients required the SAPIEN™ valve in valve implantation. Echocardiographic and angiographic control revealed no/trivial aortic incompetence (AI) in 59%, mild AI in 33.3%, and moderate AI in 7.7% of the patients. Three patients died within 30 days from a non-valve-related cause (respiratory), the patient converted did not recover from right-heart failure, and one patient died on day 19 due to unclear reasons. There was one incidence of new-onset atrioventricular (AV) block requiring pacemaker implantation. Two patients suffered a stroke (one secondary and the other intraprocedural). Transvalvular gradients were maximum 29.4±10.7mmHg and mean 14.3±6.8mmHg. The initial clinical results indicate a relatively straightforward implantation procedure and good functional results after trans-apical implantation of the Symetis Acurate™ device. Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Dongyang; Ba, Dechun; Hao, Ming; Duan, Qihui; Liu, Kun; Mei, Qi
2018-05-01
Pneumatic NC (normally closed) valves are widely used in high density microfluidics systems. To improve actuation reliability, the actuation pressure needs to be reduced. In this work, we utilize 3D FEM (finite element method) modelling to get an insight into the valve actuation process numerically. Specifically, the progressive debonding process at the elastomer interface is simulated with CZM (cohesive zone model) method. To minimize the actuation pressure, the V-shape design has been investigated and compared with a normal straight design. The geometrical effects of valve shape has been elaborated, in terms of valve actuation pressure. Based on our simulated results, we formulate the main concerns for micro valve design and fabrication, which is significant for minimizing actuation pressures and ensuring reliable operation.
NASA Astrophysics Data System (ADS)
Meng, Fei; Shi, Peng; Karimi, Hamid Reza; Zhang, Hui
2016-02-01
The main objective of this paper is to investigate the sensitivity analysis and optimal design of a proportional solenoid valve (PSV) operated pressure reducing valve (PRV) for heavy-duty automatic transmission clutch actuators. The nonlinear electro-hydraulic valve model is developed based on fluid dynamics. In order to implement the sensitivity analysis and optimization for the PRV, the PSV model is validated by comparing the results with data obtained from a real test-bench. The sensitivity of the PSV pressure response with regard to the structural parameters is investigated by using Sobol's method. Finally, simulations and experimental investigations are performed on the optimized prototype and the results reveal that the dynamical characteristics of the valve have been improved in comparison with the original valve.
Litzler, Pierre-Yves; Borz, Bogdan; Smail, Hassiba; Baste, Jean-Marc; Nafeh-Bizet, Catherine; Gay, Arnaud; Tron, Christophe; Godin, Matthieu; Caudron, Jerome; Hauville, Camille; Dacher, Jean-Nicolas; Cribier, Alain; Eltchaninoff, Hélène; Bessou, Jean-Paul
2012-03-01
The first French transapical transcatheter aortic valve implantation (TAVI) was performed in July 2007 in our department. To report 4-year outcomes of transapical implantation with the Edwards transcatheter bioprosthesis. We prospectively evaluated consecutive patients who underwent transapical implantation with an Edwards transcatheter bioprosthesis between July 2007 and October 2011. Patients were not suitable for conventional surgery (due to severe comorbidities) or transfemoral implantation (due to poor femoral access). Among 61 patients (59.0% men), mean logistic EuroSCORE was 27.5 ± 14.9% and mean age was 81.0 ± 6.8 years. Successful valve implantation was achieved in 59/61 patients (96.7%) of patients. The other two patients required conversion to conventional surgery due to prosthesis embolization and died. Six additional patients died in the postoperative period. Causes of perioperative death were two septic shocks (one of peritonitis), two multi-organ failure, one ventricular fibrillation and one respiratory insufficiency. Intraprocedural stroke was not observed in any patient. The actuarial survival rates at 1, 2 and 4 years were 73.8%, 67.2% and 41.0%. During this 4-year period, four patients died of cardiovascular events, but no impairment of transprosthesis gradient was observed. Our series of 61 patients who underwent transapical implantation of the Edwards transcatheter bioprosthesis shows satisfactory results, similar to other reports, considering the high level of severity of patients referred for this method. Transapical access is a reliable alternative method for patients that cannot benefit from a transfemoral approach. Copyright © 2012. Published by Elsevier Masson SAS.
Blot, William J; Ibrahim, Michel A; Ivey, Tom D; Acheson, Donald E; Brookmeyer, Ron; Weyman, Arthur; Defauw, Joseph; Smith, J Kermit; Harrison, Donald
2005-05-31
The first Björk-Shiley convexoconcave (BSCC) prosthetic heart valves were implanted in 1978. The 25th anniversary provided a stimulus to summarize the research data relevant to BSCC valve fracture, patient management, and current clinical options. Published and unpublished data on the risks of BSCC valve fracture and replacement were compiled, and strategies for identifying candidates for prophylactic valve reoperation were summarized. By December 2003, outlet strut fractures (OSFs), often with fatal outcomes, had been reported in 633 BSCC valves (0.7% of 86,000 valves implanted). Fractures still continue to occur, but average rates of OSFs in 60 degrees valves are now <0.1% per year. OSF risk varies markedly by valve characteristics, especially valve angle and size, with weaker effects associated with other manufacturing variables. OSF risks are mildly lower among women than men but decline sharply with advancing age. The risks of valve replacement typically greatly exceed those of OSF. By comparing individualized estimated risks of OSF versus valve replacement, guidelines have been developed to identify the small percentage of BSCC patients (mostly younger men) who would be expected to have a gain in life expectancy should reoperative surgery be performed. Twenty-five years after the initial BSCC valve implants, fractures continue to occur. Continued monitoring of BSCC patients is needed to track and quantify risks and enable periodic updating of guidelines for patients and their physicians.
Fixation and mounting of porcine aortic valves for use in mock circuits.
Schlöglhofer, Thomas; Aigner, Philipp; Stoiber, Martin; Schima, Heinrich
2013-10-01
Investigations of the circulatory system in vitro use mock circuits that require valves to mimic the cardiac situation. Whereas mechanical valves increase water hammer effects due to inherent stiffness and do not allow the use of pressure lines or catheters, bioprosthetic valves are expensive and of limited durability in test fluids. Therefore, we developed a cheap, fast, alternative method to mount valves obtained from the slaughterhouse in mock circuits. Porcine aortic roots were obtained from the abattoir and used either in native condition or after fixation. Fixation was performed at a constant retrograde pressure to ensure closed valve position. Fixation time was 4 h in a 0.5%-glutaraldehyde phosphate buffer. The fixed valves were molded into a modular mock circulation connector using a fast curing silicone. Valve functionality was evaluated in a pulsatile setting (cardiac output = 4.7 l/min, heart rate = 80 beats/min) and compared before and after fixation. Leaflet motion was recorded with a high-speed camera and valve insufficiency was quantified by leakage flow under steady pressure application (80 mmHg). Under physiological conditions the aortic valves showed almost equal leaflet motion in native and fixed conditions. However, the leaflets of the native valves showed lower stiffness and more fluttering during systole than the fixed specimens. Under retrograde pressure, fresh and fixed valves showed small leakage flows of <30 ml/min. The new mounting and fixation procedure is a fast method to fabricate low cost biologic valves for the use in mock circuits.
Lymphangiogenesis is increased in heart valve endocarditis.
Niinimäki, Eetu; Mennander, Ari A; Paavonen, Timo; Kholová, Ivana
2016-09-15
Inflammation-associated lymphangiogenesis (IAL) has been identified as part of several acute and chronic inflammation. Sparse data exist on lymphatics during endocarditis. Fifty-two patients with surgically resected valves were included. Endocarditis was present in 18 aortic and 10 mitral valves. Controls consisted of 15 degenerative aortic and 9 degenerative mitral valves. There were 22 males with endocarditis and 17 males in controls. The mean age was 58 (SD 15) years with endocarditis vs. 62 (SD 13) years for controls. Lymphatics were detected by podoplanin antibody immunohistochemistry and morphometrical analysis was performed. The lymphatic density in endocarditis was 833 (SD 529) vessels/mm(2) (range 0-1707) as compared with 39 (SD 60) vessels/mm(2) (range 0-250) in controls (p=0.000). In endocarditis, the mean lymphatic size was 153 (SD 372) μm(2) ranging from 1 to 2034μm(2), whereas it was 30 (SD 29) μm(2), with maximum 90μm(2) and minimum 2μm(2) in controls (p=0.000). IAL is increased in valves with endocarditis as compared with controls. Lymphatics in heart valves may provide a novel means for treatment strategies against endocarditis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Guteta, Senbeta; Yadeta, Dejuma; Azazh, Aklilu; Mekonnen, Dufera
2016-04-01
Valvular heart disease has been a significant cause of heart disease worldwide. In Ethiopia, it particularly affects young individuals and constitutes the major cause of cardiovascular disease. Factors associated with choice of treatment for advanced valvular heart disease are variable. The objective of this study is to review surgery done for Ethiopian patients with valvular heart disease. We analyzed data on patients who had valve surgery and follow-up at the Tikur Anbessa Specialized Hospital cardiology unit. We collected data on sociodemographic characteristics, the pre-operative status of effected valves and co-morbidities, and assessed their associations with patient management options. A total of 157 valve surgeries were done from 1983 to 2013. Mean age at time of surgery was 26.7 years and females constituted 66% of the cases. Patients with rheumatic heart disease were younger, more likely to be female and have atrial fibrillation, but less likely to have impaired left ventricular systolic function when compared to patients with non-rheumatic heart disease. More than 75% of the surgical procedures done were mechanical valve replacement. Mechanical valves, compared with bioprosthetic valves, were more likely to be used in patients with rheumatic heart disease. The median age of those receiving mechanical valves, 24 (IQR 22-28) years, was lower than those receiving bioprosthetic valves, 31.5 (IQR 29.9-37.9) years. Mechanical valve replacement was significantly higher in those under the age of 20 years (Adjusted Odds Ratio 41.0, 95% CI: 3.0-557.2) and in those between 20 and 29 years of age (Adjusted Odds Ratio 14.3, 95% CI: 2.3-88.6). Valve surgery for valvular heart diseases has been more common performed for young and female patients. A great majority of the replacements done have been with mechanical valves. As many of the patients have been younger and female, the choice of valve surgery and the need for anticoagulation impacts subsequent management of rheumatic heart disease and associated morbidities, lifestyle plans and pregnancy.
Infective endocarditis following Melody valve implantation: comparison with a surgical cohort.
O'Donnell, Clare; Holloway, Rhonda; Tilton, Elizabeth; Stirling, John; Finucane, Kirsten; Wilson, Nigel
2017-03-01
Infective endocarditis has been reported post Melody percutaneous pulmonary valve implant; the incidence and risk factors, however, remain poorly defined. We identified four cases of endocarditis from our first 25 Melody implants. Our aim was to examine these cases in the context of postulated risk factors and directly compare endocarditis rates with local surgical valves. We conducted a retrospective review of patients post Melody percutaneous pulmonary valve implant in New Zealand (October, 2009-May, 2015) and also reviewed the incidence of endocarditis in New Zealand among patients who have undergone surgical pulmonary valve implants. In total, 25 patients underwent Melody implantation at a median age of 18 years. At a median follow-up of 2.9 years, most were well with low valve gradient (median 27 mmHg) and only mild regurgitation. Two patients presented with life-threatening endocarditis and obstructive vegetations at 14 and 26 months post implant, respectively. Two additional patients presented with subacute endocarditis at 5.5 years post implant. From 2009 to May, 2015, 178 surgical pulmonic bioprostheses, largely Hancock valves and homografts, were used at our institution. At a median follow-up of 2.9 years, four patients (2%) had developed endocarditis in this group compared with 4/25 (16%) in the Melody group (p=0.0089). Three surgical valves have been replaced. The Melody valve offers a good alternative to surgical conduit replacement in selected patients. Many patients have excellent outcomes in the medium term. Endocarditis, however, can occur and if associated with obstruction can be life threatening. The risk for endocarditis in the Melody group was higher in comparison with that in a contemporaneous surgical pulmonary implant cohort.
NASA Astrophysics Data System (ADS)
Kim, Soo Jeong; Lee, Dong Hyuk; Song, Inchang; Kim, Nam Gook; Park, Jae-Hyeung; Kim, JongHyo; Han, Man Chung; Min, Byong Goo
1998-07-01
Phase-contrast (PC) method of magnetic resonance imaging (MRI) has bee used for quantitative measurements of flow velocity and volume flow rate. It is a noninvasive technique which provides an accurate two-dimensional velocity image. Moreover, Phase Contrast Cine magnetic resonance imaging combines the flow dependent contrast of PC-MRI with the ability of cardiac cine imaging to produce images throughout the cardiac cycle. However, the accuracy of the data acquired from the single through-plane velocity encoding can be reduced by the effect of flow direction, because in many practical cases flow directions are not uniform throughout the whole region of interest. In this study, we present dynamic three-dimensional velocity vector mapping method using PC-MRI which can visualize the complex flow pattern through 3D volume rendered images displayed dynamically. The direction of velocity mapping can be selected along any three orthogonal axes. By vector summation, the three maps can be combined to form a velocity vector map that determines the velocity regardless of the flow direction. At the same time, Cine method is used to observe the dynamic change of flow. We performed a phantom study to evaluate the accuracy of the suggested PC-MRI in continuous and pulsatile flow measurement. Pulsatile flow wave form is generated by the ventricular assistant device (VAD), HEMO-PULSA (Biomedlab, Seoul, Korea). We varied flow velocity, pulsatile flow wave form, and pulsing rate. The PC-MRI-derived velocities were compared with Doppler-derived results. The velocities of the two measurements showed a significant linear correlation. Dynamic three-dimensional velocity vector mapping was carried out for two cases. First, we applied to the flow analysis around the artificial heart valve in a flat phantom. We could observe the flow pattern around the valve through the 3-dimensional cine image. Next, it is applied to the complex flow inside the polymer sac that is used as ventricle in totally implantable artificial heart (TAH). As a result we could observe the flow pattern around the valves of the sac, though complex flow can not be detected correctly in the conventional phase contrast method. In addition, we could calculate the cardiac output from TAH sac by quantitative measurement of the volume of flow across the outlet valve.
Fischer, Harry C.
1977-01-01
This invention is a reversing valve having an inlet, an outlet, and an inlet-outlet port. The valve is designed to respond to the introduction of relatively high-pressure fluid at its inlet or, alternatively, of lower-pressure fluid at its inlet-outlet port. The valve includes an axially slidable assembly which is spring-biased to a position where it isolates the inlet and connects the inlet-outlet port to the outlet. The admission of high-pressure fluid to the inlet displaces the slidable assembly to a position where the outlet is isolated and the inlet is connected to the inlet-outlet port. The valve is designed to minimize pressure drops and leakage. It is of a reliable and comparatively simple design.
TAVR and SAVR: Current Treatment of Aortic Stenosis.
Hu, Patrick P
2012-01-01
Transcatheter aortic valve replacement (TAVR) was approved in the United States in late 2011, providing a critically needed alternative therapy for patients with severe aortic stenosis previously refused surgical aortic valve replacement (SAVR). Over 20,000 TAVR have been performed in patients worldwide since 2002 when Alain Cribier performed the first-in-man TAVR. This paper reviews the data from balloon expandable and self-expanding aortic stent valves as well as data comparing them with traditional surgical aortic valve replacement (SAVR). Complications using criteria established by the Valve Academic Research Consortium (VARC) are reviewed. Future challenges and possibilities are discussed and will make optimizing TAVR an important goal in the years to come.
TAVR and SAVR: Current Treatment of Aortic Stenosis
Hu, Patrick P.
2012-01-01
Transcatheter aortic valve replacement (TAVR) was approved in the United States in late 2011, providing a critically needed alternative therapy for patients with severe aortic stenosis previously refused surgical aortic valve replacement (SAVR). Over 20,000 TAVR have been performed in patients worldwide since 2002 when Alain Cribier performed the first-in-man TAVR. This paper reviews the data from balloon expandable and self-expanding aortic stent valves as well as data comparing them with traditional surgical aortic valve replacement (SAVR). Complications using criteria established by the Valve Academic Research Consortium (VARC) are reviewed. Future challenges and possibilities are discussed and will make optimizing TAVR an important goal in the years to come. PMID:22952419
Markus, Marcello Ricardo Paulista; Baumeister, Sebastian Edgar; Stritzke, Jan; Dörr, Marcus; Wallaschofski, Henri; Völzke, Henry; Lieb, Wolfgang
2013-07-01
We aimed to analyze the association between hepatic steatosis and aortic valve sclerosis in the general population. Cross-sectional data of 2212 men and women, aged 45 to 81 years, from the baseline examination of the population-based Study of Health in Pomerania (SHIP-0) were analyzed. Hepatic steatosis was primarily defined as the presence of a hyperechogenic ultrasound pattern of the liver. Aortic valve sclerosis was determined by echocardiography. In our sample, hepatic steatosis was present in 877 (39.7%) individuals. Among participants with hepatic steatosis, aortic valve sclerosis was more common (n=323; 36.8%) compared with participants without hepatic steatosis (n=379; 28.4%; P<0.001). After adjustment for potential confounders, individuals with hepatic steatosis had 33% higher odds of aortic valve sclerosis compared with those without hepatic steatosis (95% confidence interval, 6%-66%; P=0.014). Additional adjustment for high-sensitive C-reactive protein, serum ferritin levels, and white blood cells slightly reduced the association to 32% (95% confidence interval, 4%-66%; P=0.021). Our findings add evidence that hepatic steatosis and aortic valve sclerosis are interrelated after adjustment for major confounders. The release of proatherogenic substances by the steatotic liver or its contribution to insulin resistance and dyslipidemia may contribute to the development of calcification and sclerosis of the aortic valve.
High cleanliness globe valve with sine mechanism drive
NASA Astrophysics Data System (ADS)
Luo, Hu
2018-06-01
This paper gives a new type of quick-opening globe valve for life support pneumatic control system of the safety cabin at underground coal mine. The valve adopts the sine mechanism to transmit the rotating of the handle in the range of 90° to the reciprocating motion of the spool. The mechanism implements the quick-opening function of the valve through controlling the contact and separation between the O-ring and the end face of the valve. Since there is no relative sliding between the sealing interfaces, the valve solute uncontrollable disadvantage wear particles which produced by package ball valve, to ensure high cleanliness in flow path. Traditional transmission mechanism has a reinforcement effect and reduce handle open torque. By the finite element method, the relationship between the contact force and the compression of O-ring is analyzed to provide the boundary condition for the calculation of the rotational torque. Meanwhile the velocity field and pressure field along the flow path are simulated. The caliber size of the valve and the flow resistance coefficient are obtained. There is higher cleanliness, more reliable sealing, smaller handle open torque advantage compared with existing packing ball valve. The above work presents a new technical approach for the design of pneumatic control valve of the safety cabin.
Valve exploiting the principle of a side channel turbine
NASA Astrophysics Data System (ADS)
Jandourek, Pavel; Pochylý, František; Haban, Vladimír
2017-04-01
The presented article deals with a side channel turbine, which can be used as a suitable substitute for a pressure reducing valve. Pressure reducing valves are a source of high hydraulic losses. The aim is to replace them by a side channel turbine. With that in mind, hydraulic losses can be replaced by a production of electrical energy at comparable characteristics of the reducing valve and the side channel turbine. The basis for the design is the loss characteristics of the pressure reducing valve. Thereby create a new kind of turbine valve with speed-controlled flow in dependence of the runner revolution. It is technical innovation and new renewable source of energy, which can be in future used in rehabilitation or projecting of pumped-storage power plants. It also increases the power of the power plant.
Enhanced rhamnolipids production via efficient foam-control using stop valve as a foam breaker.
Long, Xuwei; Shen, Chong; He, Ni; Zhang, Guoliang; Meng, Qin
2017-01-01
In this study, a stop valve was used as a foam breaker for dealing with the massive overflowing foam in rhamnolipid fermentation. As found, a stop valve at its tiny opening could break over 90% of the extremely stable rhamnolipid foam into enriched liquid when foam flows through the sharp gap in valve. The efficient foam-control by the stop valve considerably improved the rhamnolipid fermentation and significantly enhanced the rhamnolipid productivity by 83% compared to the regular fermentation. This efficient foam breaking was mainly achieved by a high shear rate in combination with fast separation of air from the collapsed foam. Altogether, the stop valve possessed a great activity in breaking rhamnolipid foam, and the involving mechanism holds the potential for developing efficient foam breakers for industrial rhamnolipid fermentation. Copyright © 2016. Published by Elsevier Ltd.
Stoliński, Jarosław; Musiał, Robert; Plicner, Dariusz; Andres, Janusz
The aim of the study was to comparatively analyze respiratory system function after minimally invasive, through right minithoracotomy aortic valve replacement (RT-AVR) to conventional AVR. Analysis of 201 patients scheduled for RT-AVR and 316 for AVR between January 2010 and November 2013. Complications of the respiratory system and pulmonary functional status are presented. Complications of the respiratory system occurred in 16.8% of AVR and 11.0% of RT-AVR patients (P = 0.067). The rate of pleural effusions, thoracenteses, pneumonias, or phrenic nerve dysfunctions was not significantly different between groups. Perioperative mortality was 1.9% in AVR and 1.0% in RT-AVR (P = 0.417). Mechanical ventilation time after surgery was 9.7 ± 5.9 hours for AVR and 7.2 ± 3.2 hours for RT-AVR patients (P < 0.001). Stroke (odds ratio [OR] = 13.4, P = 0.008), increased postoperative blood loss (OR = 9.6, P < 0.001), and chronic obstructive pulmonary disease (OR = 7.7, P < 0.001) were risk factors of prolonged mechanical lung ventilation. A week after surgery, the results of most pulmonary function tests were lower in the AVR than in the RT-AVR group (P < 0.001 was seen for forced expiratory volume in the first second, vital capacity, total lung capacity, maximum inspiratory pressure and maximum expiratory pressure, P = 0.377 was seen for residual volume). Right anterior aortic valve replacement minithoracotomy surgery with single-lung ventilation did not result in increased rate of respiratory system complications. Spirometry examinations revealed that pulmonary functional status was more impaired after AVR in comparison with RT-AVR surgery.
van den Hoven, Allard T; Mc-Ghie, Jackie S; Chelu, Raluca G; Duijnhouwer, Anthonie L; Baggen, Vivan J M; Coenen, Adriaan; Vletter, Wim B; Dijkshoorn, Marcel L; van den Bosch, Annemien E; Roos-Hesselink, Jolien W
2017-12-01
Integration of volumetric heart chamber quantification by 3D echocardiography into clinical practice has been hampered by several factors which a new fully automated algorithm (Left Heart Model, (LHM)) may help overcome. This study therefore aims to evaluate the feasibility and accuracy of the LHM software in quantifying left atrial and left ventricular volumes and left ventricular ejection fraction in a cohort of patients with a bicuspid aortic valve. Patients with a bicuspid aortic valve were prospectively included. All patients underwent 2D and 3D transthoracic echocardiography and computed tomography. Left atrial and ventricular volumes were obtained using the automated program, which did not require manual contour detection. For comparison manual and semi-automated measurements were performed using conventional 2D and 3D datasets. 53 patients were included, in four of those patients no 3D dataset could be acquired. Additionally, 12 patients were excluded based on poor imaging quality. Left ventricular end-diastolic and end-systolic volumes and ejection fraction calculated by the LHM correlated well with manual 2D and 3D measurements (Pearson's r between 0.43 and 0.97, p < 0.05). Left atrial volume (LAV) also correlated significantly although LHM did estimate larger LAV compared to both 2DE and 3DE (Pearson's r between 0.61 and 0.81, p < 0.01). The fully automated software works well in a real-world setting and helps to overcome some of the major hurdles in integrating 3D analysis into daily practice, as it is user-independent and highly reproducible in a group of patients with a clearly defined and well-studied valvular abnormality.
NASA Astrophysics Data System (ADS)
Jeon, Juncheol; Han, Chulhee; Chung, Jye Ung; Choi, Seung-Bok
2015-01-01
In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains.
NASA Astrophysics Data System (ADS)
Hill, Marc; Rizzello, Gianluca; Seelecke, Stefan
2017-08-01
Due to their many features including lightweight and low energy consumption, dielectric elastomer (DE) membrane actuators are of interest for a number of industrial applications, such as pumping systems or valve control units. In particular, the use of DEs in valve control units offers advantages over traditional solenoid valves, including lower power requirements and relative simplicity in achieving proportional control. Additionally, DEs generate low thermal dissipation and are capable of virtually silent operation. The contribution of this work is the development of a new valve system based on a circular DE membrane pre-loaded with a linear spring. The valve is designed for pressurized air and operates by actuating a lever mechanism that opens and closes an outlet port. After presenting the operating principle and system design, several experiments are presented to compare actuator force, stroke, and dissipated energy for several pressure differentials and associated volume flows. It is observed that the DE-driven valve achieves a performance similar to a solenoid-based valve, while requiring a significantly lower amount of input energy. In addition, it is shown that DE-membrane valves can be controlled proportionally by simply adjusting the actuator voltage.
Apico-Aortic Conduit for severe aortic stenosis: Technique, applications, and systematic review
Elmistekawy, Elsayed; Lapierre, Harry; Mesana, Thierry; Ruel, Marc
2010-01-01
Patients referred for aortic valve replacement are often elderly and may have increased surgical risk associated with ascending aortic calcification, left ventricular dysfunction, presence of coronary artery disease, previous surgery, and/or presence of several co-morbidities. Some of these patients may not be considered candidates for conventional surgery because of their high risk profile. While transcatheter aortic valve replacement constitutes a widely accepted alternative, some patients may not be eligible for this modality due to anatomic factors. Apico-Aortic Conduit (AAC) insertion (aortic valve bypass surgery) constitutes a possible option in those patients. Apico-Aortic Conduit is not a new technique, as it has been used for decades in both pediatric and adult populations. However, there is a resurging interest in this technique due to the expanding scope of elderly patients being considered for the treatment of aortic stenosis. Herein, we describe our surgical technique and provide a systematic review of recent publications on AAC insertion, reporting that there is continued use and several modifications of this technique, such as performing it through a small thoracotomy without the use of the cardiopulmonary bypass. PMID:23960619
Gerson, Cindy J; Goldstein, Steven; Heacox, Albert E
2009-10-01
Cryopreservation is commonly used for the long-term storage of heart valve allografts. Despite the excellent hemodynamic performance and durability of cryopreserved allografts, reports have questioned whether cryopreservation affects the valvular structural proteins, collagen and elastin. This study uses two-photon laser scanning confocal microscopy (LSCM) to evaluate the effect of cryopreservation on collagen and elastin integrity within the leaflet and conduit of aortic and pulmonary human heart valves. To permit pairwise comparisons of fresh and cryopreserved tissue, test valves were bisected longitudinally with one segment imaged fresh and the other imaged after cryopreservation and brief storage in liquid nitrogen. Collagen was detected by second harmonic generation (SHG) stimulation and elastin by autofluorescence excitation. Qualitative analysis of all resultant images indicated the maintenance of collagen and elastin structure within leaflet and conduit post-cryopreservation. Analysis of the optimized percent laser transmission (OPLT) required for full dynamic range imaging of collagen and elastin showed that OPLT observations were highly variable among both fresh and cryopreserved samples. Changes in donor-specific average OPLT in response to cryopreservation exhibited no consistent directional trend. The donor-aggregated results predominantly showed no statistically significant change in collagen and elastin average OPLT due to cryopreservation. Since OPLT has an inverse relationship with structural signal intensity, these results indicate that there was largely no statistical difference in collagen and elastin signal strength between fresh and cryopreserved tissue. Overall, this study indicates that the conventional cryopreservation of human heart valve allografts does not detrimentally affect their collagen and elastin structural integrity.
A D-Shaped Bileaflet Bioprosthesis which Replicates Physiological Left Ventricular Flow Patterns
Tan, Sean Guo-Dong; Kim, Sangho; Hon, Jimmy Kim Fatt; Leo, Hwa Liang
2016-01-01
Prior studies have shown that in a healthy heart, there exist a large asymmetric vortex structure that aids in establishing a steady flow field in the left ventricle. However, the implantation of existing artificial heart valves at the mitral position is found to have a negative effect on this physiological flow pattern. In light of this, a novel D-shaped bileaflet porcine bioprosthesis (GD valve) has been designed based on the native geometry mitral valve, with the hypothesis that biomimicry in valve design can restore physiological left ventricle flow patterns after valve implantation. An in-vitro experiment using two dimensional particle velocimetry imaging was carried out to determine the hemodynamic performance of the new bileaflet design and then compared to that of the well-established St. Jude Epic valve which functioned as a control in the experiment. Although both valves were found to have similar Reynolds shear stress and Turbulent Kinetic Energy levels, the novel D-shape valve was found to have lower turbulence intensity and greater mean kinetic energy conservation. PMID:27258099
Rarity of invasiveness in right-sided infective endocarditis.
Hussain, Syed T; Shrestha, Nabin K; Witten, James; Gordon, Steven M; Houghtaling, Penny L; Tingleff, Jens; Navia, José L; Blackstone, Eugene H; Pettersson, Gösta B
2018-01-01
The rarity of invasiveness of right-sided infective endocarditis (IE) compared with left-sided has not been well recognized and evaluated. Thus, we compared invasiveness of right- versus left-sided IE in surgically treated patients. From January 2002 to January 2015, 1292 patients underwent surgery for active IE, 138 right-sided and 1224 left-sided. Among patients with right-sided IE, 131 had tricuspid and 7 pulmonary valve IE; 12% had prosthetic valve endocarditis. Endocarditis-related invasiveness was based on echocardiographic and operative findings. Invasive disease was rare on the right side, occurring in 1 patient (0.72%; 95% confidence interval 0.02%-4.0%); rather, it was limited to valve cusps/leaflets or was superficial. In contrast, IE was invasive in 408 of 633 patients with aortic valve (AV) IE (65%), 113 of 369 with mitral valve (MV) IE (31%), and 148 of 222 with AV and MV IE (67%). Staphylococcus aureus was a more predominant organism in right-sided than left-sided IE (right 40%, AV 19%, MV 29%), yet invasion was observed almost exclusively on the left side of the heart, which was more common and more severe with AV than MV IE and more common with prosthetic valve endocarditis than native valve IE. Rarity of right-sided invasion even when caused by S aureus suggests that invasion and development of cavities/"abscesses" in patients with IE may be driven more by chamber pressure than organism, along with other reported host-microbial interactions. The lesser invasiveness of MV compared with AV IE suggests a similar mechanism: decompression of MV annulus invasion site(s) toward the left atrium. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Deletion of CD73 in mice leads to aortic valve dysfunction.
Zukowska, P; Kutryb-Zajac, B; Jasztal, A; Toczek, M; Zabielska, M; Borkowski, T; Khalpey, Z; Smolenski, R T; Slominska, E M
2017-06-01
Aortic stenosis is known to involve inflammation and thrombosis. Changes in activity of extracellular enzyme - ecto-5'-nucleotidase (referred also as CD73) can alter inflammatory and thrombotic responses. This study aimed to evaluate the effect of CD73 deletion in mice on development of aortic valve dysfunction and to compare it to the effect of high-fat diet. Four groups of mice (normal-diet Wild Type (WT), high-fat diet WT, normal diet CD73-/-, high-fat diet CD73-/-) were maintained for 15weeks followed by echocardiographic analysis of aortic valve function, measurement of aortic surface activities of nucleotide catabolism enzymes as well as alkaline phosphatase activity, mineral composition and histology of aortic valve leaflets. CD73-/- knock out led to an increase in peak aortic flow (1.06±0.26m/s) compared to WT (0.79±0.26m/s) indicating obstruction. Highest values of peak aortic flow (1.26±0.31m/s) were observed in high-fat diet CD73-/- mice. Histological analysis showed morphological changes in CD73-/- including thickening and accumulation of dark deposits, proved to be melanin. Concentrations of Ca 2+ , Mg 2+ and PO 4 3- in valve leaflets were elevated in CD73-/- mice. Alkaline phosphatase (ALP) activity was enhanced after ATP treatment and reduced after adenosine treatment in aortas incubated in osteogenic medium. AMP hydrolysis in CD73-/- was below 10% of WT. Activity of ecto-adenosine deaminase (eADA), responsible for adenosine deamination, in the CD73-/- was 40% lower when compared to WT. Deletion of CD73 in mice leads to aortic valve dysfunction similar to that induced by high-fat diet suggesting important role of this surface protein in maintaining heart valve integrity. Copyright © 2017 Elsevier B.V. All rights reserved.
Theodoridis, Karolina; Müller, Janina; Ramm, Robert; Findeisen, Katja; Andrée, Birgit; Korossis, Sotirios; Haverich, Axel; Hilfiker, Andres
2016-10-01
Non-fixed, decellularized allogeneic heart valve scaffolds seem to be the best choice for heart valve replacement, their availability, however, is quite limited. Cryopreservation could prolong their shelf-life, allowing for their ideal match to a recipient. In this study, porcine pulmonary valves were decellularized using detergents, either prior or after cryopreservation, and analyzed. Mechanical integrity was analyzed by uniaxial tensile testing, histoarchitecture by histological staining, and composition by DNA, collagen (hydroxyproline) and GAG (chondroitin sulfate) quantification. Residual sodium dodecyl sulfate (SDS) in the scaffold was quantified by applying a methylene blue activation assay (MBAS). Cryopreserved decellularized scaffolds (DC) and scaffolds that were decellularized after cryopreservation (CD) were compared to fresh valves (F), cryopreserved native valves (C), and decellularized only scaffolds (D). The E-modulus and tensile strength of decellularized (D) tissue showed no significant difference compared to DC and CD. The decellularization resulted in an overall reduction of DNA and GAG, with DC containing the lowest amount of GAGs. The DNA content in the valvular wall of the CD group was higher than in the D and DC groups. CD valves showed slightly more residual SDS than DC valves, which might be harmful to recipient cells. In conclusion, cryopreservation after decellularization was shown to be preferable over cryopreservation before decellularization. However, in vivo testing would be necessary to determine whether these differences are significant in biocompatibility or immunogenicity of the scaffolds. Absence of adverse effects on biomechanical stability of acellular heart valve grafts by cryopreservation, neither before nor after decellularization, allows the identification of best matching patients in a less time pressure dictated process, and therefore to an optimized use of a very limited, but best-suited heart valve prosthesis. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Assessment of Parylene C Thin Films for Heart Valve Tissue Engineering
Marei, Isra; Chester, Adrian; Carubelli, Ivan; Prodromakis, Themistoklis; Trantidou, Tatiana
2015-01-01
Background: Scaffolds are a key component of tissue-engineered heart valves (TEHVs). Several approaches had been adopted in the design of scaffolds using both natural and synthetic resources. We have investigated the suitability of parylene C (PC), a vapor deposited polymeric material, for the use as a scaffold in TEHV. Aims: To evaluate the adsorption of extracellular matrix components onto plasma-activated PC and study the biocompatibility of PC by measuring cellular adhesion, viability, apoptosis, and phenotypic expression of valve endothelial and interstitial cells. Finally, the mechanical properties of PC were compared with those of native aortic valve cusp tissue. Methods: PC slides were plasma activated and then coated with gelatin, type I collagen, or fibronectin. Porcine pulmonary valve endothelial and interstitial cells were then grown on plasma oxidized PC with different types of coatings and their adhesion was observed after 20 h of incubation. Cell viability was tested using the MTS assay, and apoptosis was estimated using TUNEL staining. The mechanical properties of PC and valve tissue were measured using a Bose Mechanical Tester. Finally, cell-seeded PC films were exposed to pulsatile pressure and aortic shear stress, respectively, to test their durability in a dynamic environment. Results: Our findings show that collagen and fibronectin could bind to plasma oxidized PC. Both valve endothelial and interstitial cells adhered to protein-coated ECM. PC had a profile of mechanical stiffness and ultimate tensile strength that were comparable with or in excess of those seen in porcine aortic valve cusps. Cells were still attached to PC films after 3 days of exposure to up to 50 mmHg pulsatile pressure or aortic levels of shear stress. Conclusion: PC is a promising candidate for use as a scaffold in tissue engineering heart valves. Additional studies are required to determine both the durability and long-term performance of cell-seeded PC when in a similar hemodynamic environment to that of the aortic valve. PMID:26101808
Yamaki, F; Nakano, K; Endo, M; Hashimoto, A; Koyanagi, H
1994-02-01
Although a high incidence of strut fracture of the Björk-Shiley convexo-concave (C-C) valve prosthesis has been reported, it is still controversial whether the prosthesis functioning normally should be replaced electively. To clarify our policy for this issue, we reviewed 28 patients who had undergone mitral valve replacement with a C-C valve prosthesis, and evaluated long-term results according to STS guidelines. The incidence of valve-related complications expressed as % patient-year were; structural deterioration 0.30, nonstructural dysfunction 0.30, thromboembolism 1.20. There were no thrombosed valves, anticoagulant-related hemorrhage or prosthetic valve endocarditis. The actuarial free rate after valve replacement with the C-C at 10 years, constructed by the Kaplan-Meier method, were compared with those with St. Jude Medical (SJM) valve prosthesis. (1) Actuarial survival: 77.9 vs 87.3 (NS), (2) Reoperation-free: 91.6 vs 98.0 (p < 0.05), (3) thromboembolism-free: 83.7 vs 83.9 (NS), (4) Event-free (hospital death+reoperation+valve-related complications: 71.2 vs 77.7 (NS). The long-term results with the C-C were compatible to those with a SJM valve prosthesis. However, if a strut fracture occurs, it is very difficult to save the patient's life. The hospital mortality of re-replacement of valve prosthesis during the last 10 years, at our institute, was 2.6%, which is almost equal to the cumulative risk of strut fracture of the C-C valve after 10 years (3.0%).(ABSTRACT TRUNCATED AT 250 WORDS)
Vamvakidou, Anastasia; Jin, Wenying; Danylenko, Oleksandr; Chahal, Navtej; Khattar, Rajdeep; Senior, Roxy
2018-03-09
This study aimed to assess the value of low transvalvular flow rate (FR) for the prediction of mortality compared with low stroke volume index (SVi) in patients with low-gradient (mean gradient: <40 mm Hg), low aortic valve area (<1 cm 2 ) aortic stenosis (AS) following aortic valve intervention. Transaortic FR defined as stroke volume/left ventricular ejection time is also a marker of flow; however, no data exist comparing the relative prognostic value of these 2 transvalvular flow markers in patients with low-gradient AS who had undergone valve intervention. We retrospectively followed prospectively assessed consecutive patients with low-gradient, low aortic valve area AS who underwent aortic valve intervention between 2010 and 2014 for all-cause mortality. Of the 218 patients with mean age 75 ± 12 years, 102 (46.8%) had low stroke volume index (SVi) (<35 ml/m 2 ), 95 (43.6%) had low FR (<200 ml/s), and 58 (26.6%) had low left ventricular ejection fraction <50%. The concordance between FR and SVi was 78.8% (p < 0.005). Over a median follow-up of 46.8 ± 21 months, 52 (23.9%) deaths occurred. Patients with low FR had significantly worse outcome compared with those with normal FR (p < 0.005). In patients with low SVi, a low FR conferred a worse outcome than a normal FR (p = 0.005), but FR status did not discriminate outcome in patients with normal SVi. By contrast, SVi did not discriminate survival either in patients with normal or low FR. Low FR was an independent predictor of mortality (p = 0.013) after adjusting for age, clinical prognostic factors, European System for Cardiac Operative Risk Evaluation II, dimensionless velocity index, left ventricular mass index, left ventricular ejection fraction, heart rate, time, type of aortic valve intervention, and SVi (p = 0.59). In patients with low-gradient, low valve area aortic stenosis undergoing aortic valve intervention, low FR, not low SVi, was an independent predictor of medium-term mortality. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Del Trigo, María; Dahou, Abdellaziz; Webb, John G; Dvir, Danny; Puri, Rishi; Abdul-Jawad Altisent, Omar; Campelo-Parada, Francisco; Thompson, Chris; Leipsic, Jonathon; Stub, Dion; DeLarochellière, Robert; Paradis, Jean-Michel; Dumont, Eric; Doyle, Daniel; Mohammadi, Siamak; Pasian, Sergio; Côté, Melanie; Pibarot, Philippe; Rodés-Cabau, Josep
2016-05-01
The self-expanding Portico valve is a new transcatheter aortic valve system yielding promising preliminary results, yet there are no comparative data against earlier generation transcatheter aortic valve systems. The aim of this study was to compare the hemodynamic performance of the Portico and balloon-expandable SAPIEN XT valves in a case-matched study with echocardiographic core laboratory analysis. Twenty-two patients underwent transcatheter aortic valve implantation with the Portico 23-mm valve and were matched for aortic annulus area and mean diameter measured by multidetector computed tomography, left ventricular ejection fraction, body surface area, and body mass index with 40 patients treated with the 23-mm SAPIEN XT. Mean aortic annulus diameters were 19.6±1.3mm by transthoracic echocardiography and 21.4±1.2mm by computed tomography, with no significant between-group differences. Doppler echocardiographic images were collected at baseline and at 1-month of follow-up and were analyzed in a central echocardiography core laboratory. There were no significant between-group differences in residual mean transaortic gradients (SAPIEN XT: 10.4±3.7mmHg; Portico: 9.8±1.1mmHg; P=.49) and effective orifice areas (SAPIEN XT: 1.36±0.27cm(2); Portico, 1.37±.29cm(2); P=.54). Rates of severe prosthesis-patient mismatch (effective orifice area<0.65cm(2)/m(2)) were similar (SAPIEN XT: 13.5%; Portico: 10.0%; P=.56). No between-group differences were found in the occurrence of moderate-severe paravalvular leaks (5.0% vs 4.8% of SAPIEN XT and Portico respectively; P=.90). Transcatheter aortic valve implantation with the self-expanding Portico system yielded similar short-term hemodynamic performance compared with the balloon-expandable SAPIEN XT system for treating patients with severe aortic stenosis and small annuli. Further prospective studies with longer-term follow-up and in patients with larger aortic annuli are required. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Fiorina, Claudia; Maffeo, Diego; Curello, Salvatore; Lipartiti, Felicia; Chizzola, Giuliano; D'Aloia, Antonio; Adamo, Marianna; Mastropierro, Rosy; Gavazzi, Emanuele; Ciccarese, Camilla; Chiari, Ermanna; Ettori, Federica
2014-06-01
Balloon valvuloplasty has been considered a mandatory step of the transcatheter aortic valve implantation (TAVI), although it is not without risk. The aim of this work was to evaluate the feasibility and safety of TAVI performed without pre-dilation (direct TAVI) of the stenosed aortic valve. Between June 2012 and June 2013, 55 consecutive TAVI performed without pre-dilation at our institution using the self-expandable CoreValve prosthesis (Medtronic, Minneapolis, MN) were analyzed and compared with 45 pre-dilated TAVI performed the previous year. Inclusion criteria were a symptomatic and severe aortic stenosis. Exclusion criteria were defined as presence of pure aortic regurgitation, degenerated surgical bioprosthesis or bicuspid aortic valve and prior procedure of balloon aortic valvuloplasty performed as a bridge to TAVI. High-burden calcification in the device landing zone, assessed by CT scan, was found in most of the patients. The valve size implanted was similar in both groups. Device success was higher in direct TAVI (85%vs.64%,p=0.014), mostly driven by a significant lower incidence of paravalvular leak (PVL≥2;9%vs.33%,p=0.02). Safety combined end point at 30 days was similar in both groups. Compared to TAVI with pre-dilation, direct TAVI is feasible regardless of the presence of bulky calcified aortic valve and the valve size implanted. Device success was higher in direct TAVI, mostly driven by a lower incidence of paravalvular leak. Safety at 30 days was similar in two groups. Copyright © 2014 Elsevier Inc. All rights reserved.
Holinski, Sebastian; Zhigalov, Konstantin; Zielinski, Christina Barbara; Grubitzsch, Herko
2017-01-01
Purpose: Hemodynamic performance of aortic valve bioprostheses is essential for reliable function and durability. So far, the supra-annularly implanted stentless Sorin Freedom Solo (SFS) demonstrated unsurpassed hemodynamic properties. As contemporary stented and externally mounted pericardial bioprostheses, like the Labcor Dokimos Plus (LDP), also improve hemodynamic performance, these types of valves were compared in this study. Methods: A total of 218 patients, who underwent aortic valve replacement with the LDP or the SFS, were matched retrospectively 1:1 on variables affecting hemodynamic measurements: implanted valve size, age, sex, and body surface area (BSA). With matching tolerance for valve size and gender of 0%, for age and BSA of 5%, 57 patient-pairs were yielded. Operative data, clinical, and hemodynamic outcome were analyzed. Results: Except for slightly higher left ventricular function and lower procedural times in the SFS group, preoperative, operative, and postoperative characteristics of patient-pairs did not differ significantly. Mean pressure gradients, effective orifice areas (EOAs), and indexed EOAs were comparable. Corresponding to valve sizes of 21, 23, 25, and 27 mm, the indexed EOAs of the LDP and SFS prostheses were 1.08 ± 0.33, 0.92 ± 0.19, 0.93 ± 0.24, 0.99 ± 0.13 cm2/m2 and 0.81 ± 0.13, 0.92 ± 0.28, 0.95 ± 0.20, 1.04 ± 0.27 cm2/m2, respectively. Conclusion: Contemporary stented and stentless pericardial bioprostheses showed excellent hemodynamic properties without significant differences in EOAs and indexed EOAs. PMID:28890465
Coronary flow reserve is impaired in patients with aortic valve calcification.
Bozbas, Huseyin; Pirat, Bahar; Yildirir, Aylin; Simşek, Vahide; Sade, Elif; Eroglu, Serpil; Atar, Ilyas; Altin, Cihan; Demirtas, Saadet; Ozin, Bulent; Muderrisoglu, Haldun
2008-04-01
Calcific aortic valve disease is an active and progressive condition. Data indicate that aortic valve calcification (AVC) is associated with endothelial dysfunction and accepted as a manifestation of atherosclerosis. Coronary flow reserve (CFR) determined by transthoracic echocardiography has been introduced as a reliable indicator for coronary microvascular function. In this study we aimed to evaluate CFR in patients with AVC. Eighty patients, aged more than 60 years, without coronary heart disease or diabetes mellitus were included: 40 had AVC without significant stenosis (peak gradient across the valve <25 mm Hg) and 40 had normal aortic valves (controls). Using transthoracic Doppler echocardiography, we measured coronary diastolic peak flow velocities (PFV) at baseline and after dipyridamole infusion. CFR was calculated as the ratio of hyperemic to baseline diastolic PFV and was compared between groups. Mean ages for patients with AVC and controls were 68.9+/-6.2 and 67.6+/-5.9 years (P=.3). There were no significant differences regarding clinical characteristics, laboratory findings, ejection fraction, or peak aortic valve gradients. Mean diastolic PFV at baseline and during hyperemia were 28.4+/-4.2 and 59.2+/-7.8 cm/s for AVC and 27.7+/-3.9 and 68.5+/-10.5 cm/s for controls. Compared with controls, patients with AVC had significantly lower CFR values (2.12+/-0.41 versus 2.51+/-0.51; P<.0001). CFR is impaired in patients with AVC before valve stenosis develops, suggesting that microvascular-endothelial dysfunction is present during the early stages of the calcific aortic valve disease.
The Economics of Transcatheter Valve Interventions.
Sud, Maneesh; Tam, Derrick Y; Wijeysundera, Harindra C
2017-09-01
A subset of patients who require correction of a stenotic or incompetent valve are deemed to be at excessive surgical risk, which precludes surgical repair or replacement. Transcatheter valve interventions are viable alternatives in these patients. However, these technologies are costly, and in the setting of a constrained Canadian health care budget, economic value is an important consideration to allow for fair allocation of scarce resources. Accordingly, we review the economic literature on transcatheter valve interventions, targeting a general audience. Our specific goals are highlighting how best to interpret these studies and discuss the implications of these technologies on the Canadian health care system. Transcatheter aortic valve replacement (TAVR) is a cost-effective alternative for inoperable patients who otherwise would receive medical therapy. When compared with surgical aortic valve replacement (SAVR), TAVR is associated with significant reductions in postprocedure hospital resource use, which offsets the substantially higher cost of the TAVR valve system relative to SAVR valves. Although cost-effectiveness estimates for TAVR in high-risk operable candidates vary widely across studies, based on contemporary data from the perspective of the Canadian health care system, TAVR is likely to provide economic value. Recent studies suggest that when compared with medical therapy for severe degenerative mitral regurgitation, the MitraClip (Abbott, Abbott Park, IL) may offer economic value in high-risk patients; however, in the absence of randomized controlled trials, this is speculative. Nonetheless, these transcatheter technologies represent a paradigm shift in the management of valvular disease; their dissemination will have substantial impact in cardiovascular care delivery. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Electrodynamic actuators for rocket engine valves
NASA Technical Reports Server (NTRS)
Fiet, O.; Doshi, D.
1972-01-01
Actuators, employed in acoustic loudspeakers, operate liquid rocket engine valves by replacing light paper cones with flexible metal diaphragms. Comparative analysis indicates better response time than solenoid actuators, and improved service life and reliability.
Cicekcioglu, Ferit; Ozen, Anil; Tuluce, Hicran; Tutun, Ufuk; Parlar, Ali Ihsan; Kervan, Umit; Karakas, Sirel; Katircioglu, Salih Fehmi
2008-01-01
Although neurologic outcome after cardiac surgery is well-established, neurocognitive functions after beating heart mitral valve replacement still needs to be elucidated. The aim of this study was to compare preoperative and postoperative neurocognitive functions in patients who underwent beating heart mitral valve replacement on cardiopulmonary bypass without cross-clamping the aorta. The prospective study included 25 consecutive patients who underwent mitral valve replacement. The operations were carried out on a beating heart method using normothermic cardiopulmonary bypass without cross-clamping the aorta. All patients were evaluated preoperatively (E1) and postoperatively (at sixth day [E2] and second month [E3]) for neurocognitive functions. Neurologic deficit was not observed in the postoperative period. Comparison of the neurocognitive test results, between the preoperative and postoperative assessment for both hemispheric cognitive functions, demonstrated that no deterioration occurred. In the three subsets of left hemispheric cognitive function test evaluation, total verbal learning, delayed recall, and recognition, significant improvements were detected at the postoperative second month (E3) compared to the preoperative results (p = 0.005, 0.01, and 0.047, respectively). Immediate recall and retention were significantly improved within the first postoperative week (E2) when compared to the preoperative results (p = 0.05 and 0.05, respectively). The technique of mitral valve replacement with normothermic cardiopulmonary bypass without cross-clamping of the aorta may be safely used for majority of patients requiring mitral valve replacement without causing deterioration in neurocognitive functions.
Cost-effectiveness of homograft heart valve replacement surgery: an introductory study.
Yaghoubi, Mohsen; Aghayan, Hamid Reza; Arjmand, Babak; Emami-Razavi, Seyed Hassan
2011-05-01
The clinical effectiveness of heart valve replacement surgery has been well documented. Mechanical and homograft valves are used routinely for replacement of damaged heart valves. Homograft valves are produced in our country but we import the mechanical valves. To our knowledge the cost-effectiveness of homograft valve has not been assessed. The objective of the present study was to compare the cost-effectiveness of homograft valve replacement with mechanical valve replacement surgery. Our samples were selected from 200 patients that underwent homograft and mechanical heart valve replacement surgery in Imam-Khomeini hospital (2000-2005). In each group we enrolled 30 patients. Quality of life was measured using the SF-36 questionnaire and utility was measured in quality-adjusted life years (QALYs). For each group we calculated the price of heart valve and hospitalization charges. Finally the cost-effectiveness of each treatment modalities were summarized as costs per QALYs gained. Forty male and twenty female participated in the study. The mean score of quality of life was 66.06 (SD = 9.22) in homograft group and 57.85 (SD = 11.30) in mechanical group (P < 0.05). The mean QALYs gained in homograft group was 0.67 more than mechanical group. The incremental cost-effectiveness ratio (ICER) revealed a cost savings of 1,067 US$ for each QALY gained in homograft group. Despite limitation of this introductory study, we concluded that homograft valve replacement was more effective and less expensive than mechanical valve. These findings can encourage healthcare managers and policy makers to support the production of homograft valves and allocate more recourse for developing such activities.
Benito, Natividad; Miró, José M.; de Lazzari, Elisa; Cabell, Christopher H; del Río, Ana; Altclas, Javier; Commerford, Patrick; Delahaye, Francois; Dragulescu, Stefan; Giamarellou, Helen; Habib, Gilbert; Kamarulzaman, Adeeba; Kumar, A. Sampath; Nacinovich, Francisco M.; Suter, Fredy; Tribouilloy, Christophe; Venugopal, K; Moreno, Asuncion; Fowler, Vance G.
2013-01-01
Background The clinical profile and outcome of nosocomial and non-nosocomial health care–associated native valve endocarditis are not well defined. Objective To describe the prevalence, clinical characteristics, and outcomes of nosocomial and non-nosocomial health care–associated native valve endocarditis. Design Prospective observational study. Setting 61 hospitals in 28 countries. Patients Patients with definite native valve endocarditis and no history of injection drug use who were enrolled in the International Collaboration on Endocarditis–Prospective Cohort Study from June 2000 to August 2005. Measurements Characteristics of nosocomial and non-nosocomial health care–associated native valve endocarditis cases were described and compared with those cases acquired in the community. Results Health care–associated native valve endocarditis was present in 557 (34%) of 1622 patients with native valve endocarditis and no history of injection drug use (nosocomial native valve endocarditis 303 patients [54%]; non-nosocomial health care–associated native valve endocarditis 254 patients [46%]). Staphylococcus aureus was the most common cause of health care-associated native valve endocarditis (nosocomial native valve endocarditis, 47%; non-nosocomial health care–associated native valve endocarditis, 42%; p=0.3), with a notable proportion of methicillin-resistant S. aureus (nosocomial native valve endocarditis, 57%; non-nosocomial health care–associated native valve endocarditis, 41%; p=0.014). Patients with health care–associated native valve endocarditis had lower rates of cardiac surgery (41% health care–associated native valve endocarditis vs 51% community-acquired native valve endocarditis, p<0.001) and higher in-hospital mortality rates than patients with community-acquired native valve endocarditis (25% health care–associated native valve endocarditis vs. 13% community-acquired native valve endocarditis vs., p<0.001). Multivariable analysis confirmed a higher mortality associated with health care–associated native valve endocarditis (incidence risk ratio=1.20 (CI 95%, 1.03–1.61). Limitations This study involves tertiary hospitals with cardiac surgery programs. The results may not be generalized to patient populations receiving care in other types of facility. Conclusions More than one-third of all cases of native valve endocarditis in non-drug users involve contact with health care. S. aureus is the leading cause of health care–associated native valve endocarditis. Non-nosocomial health care–associated native valve endocarditis is common, especially in the US. Patients with health care-associated and community-acquired native valve endocarditis differ in their presentation, microbiology, and outcome. By contrast, patients with nosocomial and non-nosocomial healthcare-associated endocarditis are similar. PMID:19414837
Geometrical dependence of spin current absorption into a ferromagnetic nanodot
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nomura, Tatsuya; Ohnishi, Kohei; Kimura, Takashi, E-mail: t-kimu@phys.kyushu-u.ac.jp
We have investigated the absorption property of the diffusive pure spin current due to a ferromagnetic nanodot in a laterally configured ferromagnetic/nonmagnetic hybrid nanostructure. The spin absorption in a nano-pillar-based lateral-spin-valve structure was confirmed to increase with increasing the lateral dimension of the ferromagnetic dot. However, the absorption efficiency was smaller than that in a conventional lateral spin valve based on nanowire junctions because the large effective cross section of the two dimensional nonmagnetic film reduces the spin absorption selectivity. We also found that the absorption efficiency of the spin current is significantly enhanced by using a thick ferromagnetic nanodot.more » This can be understood by taking into account the spin absorption through the side surface of the ferromagnetic dot quantitatively.« less
NASA Technical Reports Server (NTRS)
Sanders, B. W.
1980-01-01
The throat of a Mach 2.5 inlet that was attached to a turbojet engine was fitted with a poppet-valve-controlled stability bypass system that was designed to provide a large, stable airflow range. Propulsion system response and stability bypass performance were determined for several transient airflow disturbances, both internal and external. Internal airflow disturbances included reductions in overboard bypass airflow, power lever angle, and primary-nozzle area as well as compressor stall. For reference, data are also included for a conventional, fixed-exit bleed system. The poppet valves greatly increased inlet stability and had no adverse effects on propulsion system performance. Limited unstarted-inlet bleed performance data are presented.
Real-time 3D transesophageal echocardiography for the evaluation of rheumatic mitral stenosis.
Schlosshan, Dominik; Aggarwal, Gunjan; Mathur, Gita; Allan, Roger; Cranney, Greg
2011-06-01
The aims of this study were: 1) to assess the feasibility and reliability of performing mitral valve area (MVA) measurements in patients with rheumatic mitral valve stenosis (RhMS) using real-time 3-dimensional transesophageal echocardiography (3DTEE) planimetry (MVA(3D)); 2) to compare MVA(3D) with conventional techniques: 2-dimensional (2D) planimetry (MVA(2D)), pressure half-time (MVA(PHT)), and continuity equation (MVA(CON)); and 3) to evaluate the degree of mitral commissural fusion. 3DTEE is a novel technique that provides excellent image quality of the mitral valve. Real-time 3DTEE is a relatively recent enhancement of this technique. To date, there have been no feasibility studies investigating the utility of real-time 3DTEE in the assessment of RhMS. Forty-three consecutive patients referred for echocardiographic evaluation of RhMS and suitability for percutaneous mitral valvuloplasty were assessed using 2D transthoracic echocardiography and real-time 3DTEE. MVA(3D), MVA(2D), MVA(PHT), MVA(CON), and the degree of commissural fusion were evaluated. MVA(3D) assessment was possible in 41 patients (95%). MVA(3D) measurements were significantly lower compared with MVA(2D) (mean difference: -0.16 ± 0.22; n=25, p<0.005) and MVA(PHT) (mean difference: -0.23 ± 0.28 cm(2); n=39, p<0.0001) but marginally greater than MVA(CON) (mean difference: 0.05 ± 0.22 cm(2); n=24, p=0.82). MVA(3D) demonstrated best agreement with MVA(CON) (intraclass correlation coefficient [ICC] 0.83), followed by MVA(2D) (ICC 0.79) and MVA(PHT) (ICC 0.58). Interobserver and intraobserver agreement was excellent for MVA(3D), with ICCs of 0.93 and 0.96, respectively. Excellent commissural evaluation was possible in all patients using 3DTEE. Compared with 3DTEE, underestimation of the degree of commissural fusion using 2D transthoracic echocardiography was observed in 19%, with weak agreement between methods (κ<0.4). MVA planimetry is feasible in the majority of patients with RhMS using 3DTEE, with excellent reproducibility, and compares favorably with established methods. Three-dimensional transesophageal echocardiography allows excellent assessment of commissural fusion. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
O'Sullivan, Katie E; Gough, Aideen; Segurado, Ricardo; Barry, Mitchel; Sugrue, Declan; Hurley, John
2014-05-01
Paravalvular regurgitation (PVR) following transcatheter aortic valve implantation (TAVI) is associated with poor survival. The two main valve delivery systems used to date differ significantly in both structure and deployment technique. The primary objective of this study was to perform a systematic review and meta-analysis of studies identifying PVR in patients post-TAVI using Medtronic CoreValve (MCV) and Edward Sapien (ES) valves in order to identify whether a significant difference exists between valve types. The secondary objective was to identify additional factors predisposing to PVR to provide an overview of the other associated considerations. A systematic review and meta-analysis of the current literature to identify PVR rate in patients with MCV and ES valves was performed. We also sought to examine other factors predisposing to PVR. A total of 5910 patients were identified from 9 studies. PVR rates for MCV and ES were analysed. MCV was associated with a higher PVR rate of 15.75% [95% confidence interval (CI) 12.48-19.32] compared with ES 3.93% [95% CI 1.05-8.38]. We separately reviewed predisposing factors associated with PVR. A formal comparison of the MCV and ES valve leakage rates by mixed-effects meta-regression with a fixed-effect moderator variable for valve type (MCV or ES) suggested a statistically significant difference in leakage rate between the two valve types (P = 0.0002). Unfavourable anatomical and pathological factors as well as valve choice have an impact on rates of PVR. Additionally, certain anatomical features dictate valve choice. A direct comparison of all the predisposing factors at this time is not possible and will require prospective multivariate analysis. There is, however, a significant difference in the PVR rates between valves based on the published observational data available to date. The ES valve associated with a lower incidence of PVR overall; therefore, we conclude that valve choice is indeed a significant determinant of PVR post-TAVI.
Sritharan, Deepa; Fathi, Parinaz; Weaver, Jason D; Retta, Stephen M; Wu, Changfu; Duraiswamy, Nandini
2018-06-12
After implantation of a transcatheter bioprosthetic heart valve its original circular circumference may become distorted, which can lead to changes in leaflet coaptation and leaflets that are stretched or sagging. This may lead to early structural deterioration of the valve as seen in some explanted transcatheter heart valves. Our in vitro study evaluates the effect of leaflet deformations seen in elliptical configurations on the damage patterns of the leaflets, with circular valve deformation as the control. Bovine pericardial tissue heart valves were subjected to accelerated wear testing under both circular (N = 2) and elliptical (N = 4) configurations. The elliptical configurations were created by placing the valve inside custom-made elliptical holders, which caused the leaflets to sag or stretch. The hydrodynamic performance of the valves was monitored and high resolution images were acquired to evaluate leaflet damage patterns over time. In the elliptically deformed valves, sagging leaflets experienced more damage from wear compared to stretched leaflets; the undistorted leaflets of the circular valves experienced the least leaflet damage. Free-edge thinning and tearing were the primary modes of damage in the sagging leaflets. Belly region thinning was seen in the undistorted and stretched leaflets. Leaflet and fabric tears at the commissures were seen in all valve configurations. Free-edge tearing and commissure tears were the leading cause of valve hydrodynamic incompetence. Our study shows that mechanical wear affects heart valve pericardial leaflets differently based on whether they are undistorted, stretched, or sagging in a valve configuration. Sagging leaflets are more likely to be subjected to free-edge tear than stretched or undistorted leaflets. Reducing leaflet stress at the free edge of non-circular valve configurations should be an important factor to consider in the design and/or deployment of transcatheter bioprosthetic heart valves to improve their long-term performance.
Diaphragmless shock wave generators for industrial applications of shock waves
NASA Astrophysics Data System (ADS)
Hariharan, M. S.; Janardhanraj, S.; Saravanan, S.; Jagadeesh, G.
2011-06-01
The prime focus of this study is to design a 50 mm internal diameter diaphragmless shock tube that can be used in an industrial facility for repeated loading of shock waves. The instantaneous rise in pressure and temperature of a medium can be used in a variety of industrial applications. We designed, fabricated and tested three different shock wave generators of which one system employs a highly elastic rubber membrane and the other systems use a fast acting pneumatic valve instead of conventional metal diaphragms. The valve opening speed is obtained with the help of a high speed camera. For shock generation systems with a pneumatic cylinder, it ranges from 0.325 to 1.15 m/s while it is around 8.3 m/s for the rubber membrane. Experiments are conducted using the three diaphragmless systems and the results obtained are analyzed carefully to obtain a relation between the opening speed of the valve and the amount of gas that is actually utilized in the generation of the shock wave for each system. The rubber membrane is not suitable for industrial applications because it needs to be replaced regularly and cannot withstand high driver pressures. The maximum shock Mach number obtained using the new diaphragmless system that uses the pneumatic valve is 2.125 ± 0.2%. This system shows much promise for automation in an industrial environment.
NASA Technical Reports Server (NTRS)
Wichmann, Horst; Marquardt, Kaiser; Goforth, Alyssa
1993-01-01
Design of a direct-acting valve (DAV) for a primary thruster which is fully interchangeable with a thruster equipped with pilot-operated valves is described. The DAV is based on a bellows to isolate propellants form the actuator for maximum resistance to iron nitrate and other contamination and to select optimum materials for the actuator. It provides improved seal performance under all operating conditions and insensitivity to pressure transients. As compared with the existing pilot-operated valve, the DAV design is much simpler, consists of fewer parts, and will be lower in cost.
Si, Chaorun; Hu, Songtao; Cao, Xiaobao; Wu, Weichao
2017-01-01
Due to their ease of fabrication, facile use and low cost, ice valves have great potential for use in microfluidic platforms. For this to be possible, a rapid response speed is key and hence there is still much scope for improvement in current ice valve technology. Therefore, in this study, an ice valve with enhanced thermal conductivity and a movable refrigeration source has been developed. An embedded aluminium cylinder is used to dramatically enhance the heat conduction performance of the microfluidic platform and a movable thermoelectric unit eliminates the thermal inertia, resulting in a faster cooling process. The proposed ice valve achieves very short closing times (0.37 s at 10 μL/min) and also operates at high flow rates (1150 μL/min). Furthermore, the response time of the valve decreased by a factor of 8 when compared to current state of the art technology. PMID:28084447
NASA Astrophysics Data System (ADS)
Si, Chaorun; Hu, Songtao; Cao, Xiaobao; Wu, Weichao
2017-01-01
Due to their ease of fabrication, facile use and low cost, ice valves have great potential for use in microfluidic platforms. For this to be possible, a rapid response speed is key and hence there is still much scope for improvement in current ice valve technology. Therefore, in this study, an ice valve with enhanced thermal conductivity and a movable refrigeration source has been developed. An embedded aluminium cylinder is used to dramatically enhance the heat conduction performance of the microfluidic platform and a movable thermoelectric unit eliminates the thermal inertia, resulting in a faster cooling process. The proposed ice valve achieves very short closing times (0.37 s at 10 μL/min) and also operates at high flow rates (1150 μL/min). Furthermore, the response time of the valve decreased by a factor of 8 when compared to current state of the art technology.
Actuation and system design and evaluation OMS engine shutoff valve, Volume 1. [space shuttles
NASA Technical Reports Server (NTRS)
Dunn, V. B.
1975-01-01
A technology program was conducted to identify and verify the optimum valve and actuation system concept for the Space Shuttle Orbit Maneuvering System engine. Of major importance to the valve and actuation system selection was the ten-year, 100-mission, 10,000-cycle life requirement, while maintaining high reliability, low leakage, and low weight. Valve and actuation system concepts were comparatively evaluated against past valve failure reports and potential failure modes due to the shuttle mission profile to aid in the selection of the most optimum concept for design, manufacture and verification testing. Two valve concepts were considered during the preliminary design stage; i.e., the moving seat and lifting ball. Two actuation systems were manufactured and tested. Test results demonstrate the viability of a lifting ball concept as well as the applicability of an ac motor actuation system to best meet the requirements of the shuttle mission.
System and method for damping vibration in a drill string using a magnetorheological damper
Wassell, Mark Ellsworth; Burgess, Daniel E.; Barbely, Jason R.; Thompson, Fred Lamar
2018-05-22
A system for damping vibration in a drill string can include a magnetorheological fluid valve assembly having a supply of a magnetorheological fluid. A remanent magnetic field is induced in the valve during operation that can be used to provide the magnetic field for operating the valve so as to eliminate the need to energize the coils except temporarily when changing the amount of damping required. The current to be supplied to the coil for inducing a desired magnetic field in the valve is determined based on the limiting hysteresis curve of the valve and the history of the magnetization of the value using a binary search methodology. The history of the magnetization of the valve is expressed as a series of sets of current and it resulting magnetization at which the current experienced a reversal compared to prior values of the current.
A high-frequency servosystem for fuel control in hypersonic engines
NASA Technical Reports Server (NTRS)
Simon, Donald L.
1991-01-01
A hydrogen fuel-flow valve with an electrohydraulic servosystem is described. An analysis of the servosystem is presented along with a discussion of the limitations imposed on system performance by nonlinearities. The response of the valve to swept-frequency inputs is experimentally determined and compared with analytical results obtained from a computer model. The valve is found to perform favorably for frequencies up to 200 Hz.
NASA Astrophysics Data System (ADS)
Barakat, Mohammed; Lengsfeld, Corinne; Dvir, Danny; Azadani, Ali
2017-11-01
Transcatheter aortic valves provide superior systolic hemodynamic performance in terms of valvular pressure gradient and effective orifice area compared with equivalent size surgical bioprostheses. However, in depth investigation of the flow field structures is of interest to examine the flow field characteristics and provide experimental evidence necessary for validation of computational models. The goal of this study was to compare flow field characteristics of the three most commonly used transcatheter and surgical valves using phase-locked particle image velocimetry (PIV). 26mm SAPIEN 3, 26mm CoreValve, and 25mm PERIMOUNT Magna were examined in a pulse duplicator with input parameters matching ISO-5840. A 2D PIV system was used to obtain the velocity fields. Flow velocity and shear stress were obtained during the entire cardiac cycle. In-vitro testing showed that mean gradient was lowest for SAPIEN 3, followed by CoreValve and PERIMOUNT Magna. In all the valves, the peak jet velocity and maximum viscous shear stress were 2 m/s and 2 MPa, respectively. In conclusion, PIV was used to investigate flow field downstream of the three bioprostheses. Viscous shear stress was low and consequently shear-induced thrombotic trauma or shear-induced damage to red blood cells is unlikely.
NASA Astrophysics Data System (ADS)
Zhou, Changjiang; Hu, Bo; Chen, Siyu; He, Liping
2017-12-01
An enhanced flexible dynamic model for a valve train with clearance and multi-directional deformations is proposed based on finite element method (FEM), and verified by experiment. According to the measured cam profile, the available internal excitations in numerical solution to the model are achieved by using piecewise cubic Hermite interpolating polynomial. The comparative analysis demonstrates that the bending deformation of the rocker arm is much larger than the radial deformation, signifying the necessities of multi-directional deformations in dynamic analysis for the valve train. The effects of valve clearance and cam rotation speed on contact force, acceleration and dynamic transmission error (DTE) are investigated. Both theoretical predictions and experimental measurements show that the amplitudes and fluctuations of contact force, acceleration and DTE become larger, when the valve clearance or cam speed increases. It is found that including the elasticity and the damping will weaken the impact between the rocker arm and the valve on the components (not adjacent to the valve) at either unseating or seating scenario. Additionally, as valve clearance or cam rotation speed becomes larger, the valve lift and the working phase decrease, which eventually leads to inlet air reduction. Furthermore, our study shows that the combustion rate improvement, input torque, and components durability can be improved by tuning valve clearance or adjustment the cam profile.
Early Identification of Aortic Valve Sclerosis Using Iron Oxide Enhanced MRI
Hamilton, Amanda M.; Rogers, Kem A.; Belisle, Andre J.L.; Ronald, John A.; Rutt, Brian K.; Weissleder, Ralph; Boughner, Derek R.
2017-01-01
Purpose To test the ability of MION-47 enhanced MRI to identify tissue macrophage infiltration in a rabbit model of aortic valve sclerosis (AVS). Materials and Methods The aortic valves of control and cholesterol-fed New Zealand White rabbits were imaged in vivo pre- and 48 h post-intravenous administration of MION-47 using a 1.5 Tesla (T) MR clinical scanner and a CINE fSPGR sequence. MION-47 aortic valve cusps were imaged ex vivo on a 3.0T whole-body MR system with a custom gradient insert coil and a three-dimensional (3D) FIESTA sequence and compared with aortic valve cusps from control and cholesterol-fed contrast-free rabbits. Histopathological analysis was performed to determine the site of iron oxide uptake. Results MION-47 enhanced the visibility of both control and cholesterol-fed rabbit valves in in vivo images. Ex vivo image analysis confirmed the presence of significant signal voids in contrast-administered aortic valves. Signal voids were not observed in contrast-free valve cusps. In MION-47 administered rabbits, histopathological analysis revealed iron staining not only in fibrosal macrophages of cholesterol-fed valves but also in myofibroblasts from control and cholesterol-fed valves. Conclusion Although iron oxide labeling of macrophage infiltration in AVS has the potential to detect the disease process early, a macrophage-specific iron compound rather than passive targeting may be required. PMID:20027578
Laser Doppler anemometry measurements of steady flow through two bi-leaflet prosthetic heart valves
Bazan, Ovandir; Ortiz, Jayme Pinto; Vieira Junior, Francisco Ubaldo; Vieira, Reinaldo Wilson; Antunes, Nilson; Tabacow, Fabio Bittencourt Dutra; Costa, Eduardo Tavares; Petrucci Junior, Orlando
2013-01-01
Introduction In vitro hydrodynamic characterization of prosthetic heart valves provides important information regarding their operation, especially if performed by noninvasive techniques of anemometry. Once velocity profiles for each valve are provided, it is possible to compare them in terms of hydrodynamic performance. In this first experimental study using laser doppler anemometry with mechanical valves, the simulations were performed at a steady flow workbench. Objective To compare unidimensional velocity profiles at the central plane of two bi-leaflet aortic prosthesis from St. Jude (AGN 21 - 751 and 21 AJ - 501 models) exposed to a steady flow regime, on four distinct sections, three downstream and one upstream. Methods To provide similar conditions for the flow through each prosthesis by a steady flow workbench (water, flow rate of 17L/min. ) and, for the same sections and sweeps, to obtain the velocity profiles of each heart valve by unidimensional measurements. Results It was found that higher velocities correspond to the prosthesis with smaller inner diameter and instabilities of flow are larger as the section of interest is closer to the valve. Regions of recirculation, stagnation of flow, low pressure, and flow peak velocities were also found. Conclusions Considering the hydrodynamic aspect and for every section measured, it could be concluded that the prosthesis model AGN 21 - 751 (RegentTM) is superior to the 21 AJ - 501 model (Master Series). Based on the results, future studies can choose to focus on specific regions of the these valves. PMID:24598950
Kangaroo vs. porcine aortic valves: calcification potential after glutaraldehyde fixation.
Narine, K; Chéry, Cyrille C; Goetghebeur, Els; Forsyth, R; Claeys, E; Cornelissen, Maria; Moens, L; Van Nooten, G
2005-01-01
The aim of this study was to evaluate and compare the calcification potential of kangaroo and porcine aortic valves after glutaraldehyde fixation at both low (0.6%) and high (2.0%) concentrations of glutaraldehyde in the rat subcutaneous model. To our knowledge this is the first report comparing the time-related, progressive calcification of these two species in the rat subcutaneous model. Twenty-two Sprague-Dawley rats were each implanted with two aortic valve leaflets (porcine and kangaroo) after fixation in 0.6% glutaraldehyde and two aortic valve leaflets (porcine and kangaroo) after fixation in 2% glutaraldehyde respectively. Animals were sacrificed after 24 h and thereafter weekly for up to 10 weeks after implantation. Calcium content was determined using inductively coupled plasma-mass spectrometry and confirmed histologically. Mean calcium content per milligram of tissue (dry weight) treated with 0.6 and 2% glutaraldehyde was 116.2 and 110.4 microg/mg tissue for kangaroo and 95.0 and 106.8 microg/mg tissue for porcine valves. Calcium content increased significantly over time (8.8 microg/mg tissue per week) and was not significantly different between groups. Regression analysis of calcification over time showed no significant difference in calcification of valves treated with 0.6 or 2% glutaraldehyde within and between the two species. Using the subcutaneous model, we did not detect a difference in calcification potential between kangaroo and porcine aortic valves treated with either high or low concentrations of glutaraldehyde. Copyright 2005 S. Karger AG, Basel.
Nalluri, Nikhil; Atti, Varunsiri; Munir, Abdullah B; Karam, Boutros; Patel, Nileshkumar J; Kumar, Varun; Vemula, Praveen; Edla, Sushruth; Asti, Deepak; Paturu, Amrutha; Gayam, Sriramya; Spagnola, Jonathan; Barsoum, Emad; Maniatis, Gregory A; Tamburrino, Frank; Kandov, Ruben; Lafferty, James; Kliger, Chad
2018-05-20
Bioprosthetic (BP) valves have been increasingly used for aortic valve replacement over the last decade. Due to their limited durability, patients presenting with failed BP valves are rising. Valve in Valve - Transcatheter Aortic Valve Implantation (ViV-TAVI) emerged as an alternative to the gold standard redo-Surgical Aortic Valve Replacement (redo-SAVR). However, the utility of ViV-TAVI is poorly understood. A systematic electronic search of the scientific literature was done in PubMed, EMBASE, SCOPUS, Google Scholar, and ClinicalTrials.gov. Only studies which compared the safety and efficacy of ViV-TAVI and redo-SAVR head to head in failed BP valves were included. Six observational studies were eligible and included 594 patients, of whom 255 underwent ViV- TAVI and 339 underwent redo-SAVR. There was no significant difference between ViV-TAVI and redo- SAVR for procedural, 30 day and 1 year mortality rates. ViV-TAVI was associated with lower risk of permanent pacemaker implantation (PPI) (OR: 0.43, CI: 0.21-0.89; P = 0.02) and a trend toward increased risk of paravalvular leak (PVL) (OR: 5.45, CI: 0.94-31.58; P = 0.06). There was no significant difference for stroke, major bleeding, vascular complications and postprocedural aortic valvular gradients more than 20 mm-hg. Our results reiterate the safety and feasibility of ViV-TAVI for failed aortic BP valves in patients deemed to be at high risk for surgery. VIV-TAVI was associated with lower risk of permanent pacemaker implantation with a trend toward increased risk of paravalvular leak. © 2018, Wiley Periodicals, Inc.
Dauskardt, R H; Ritchie, R O; Takemoto, J K; Brendzel, A M
1994-07-01
A fracture-mechanics based study has performed to characterize the fracture toughness and rates of cyclic fatigue-crack growth of incipient flaws in prosthetic heart-valve components made of pyrolytic carbon-coated graphite. Such data are required to predict the safe structural lifetime of mechanical heart-valve prostheses using damage-tolerant analysis. Unlike previous studies where fatigue-crack propagation data were obtained using through-thickness, long cracks (approximately 2-20 mm long), growing in conventional (e.g., compact-tension) samples, experiments were performed on physically small cracks (approximately 100-600 microns long), initiated on the surface of the pyrolytic-carbon coating to simulate reality. Small-crack toughness results were found to agree closely with those measured conventionally with long cracks. However, similar to well-known observations in metal fatigue, it was found that based on the usual computations of the applied (far-field) driving force in terms of the maximum stress intensity, Kmax, small fatigue cracks grew at rates that exceeded those of long cracks at the same applied stress intensity, and displayed a negative dependency on Kmax; moreover, they grew at applied stress intensities less than the fatigue threshold value, below which long cracks are presumed dormant. To resolve this apparent discrepancy, it is shown that long and small crack results can be normalized, provided growth rates are characterized in terms of the total (near-tip) stress intensity (incorporating, for example, the effect of residual stress); with this achieved, in principle, either form of data can be used for life prediction of implant devices. Inspection of the long and small crack results reveals extensive scatter inherent in both forms of growth-rate data for the pyrolytic-carbon material.
Comparison of Outcomes of Resident-performed Ahmed Valve Implantation vs Trabeculectomy
Kammerdiener, Leah L; Wannamaker, Kendall W; Fan, Jie; Sharpe, Elizabeth D
2016-01-01
ABSTRACT Aims: To compare outcomes of resident-performed Ahmed valve surgery vs trabeculectomy in a Veteran Affairs medical facility. Materials and methods: A retrospective cohort of 103 eyes in 91 patients receiving Ahmed valve (valve) or trabeculectomy (trab) performed at a Veterans Administration Medical Center by residents in their third year of training. The primary outcomes included intraocular pressure (IOP), treatment failure, and complications over 1 year. Results: Of 103 eyes, 44 received valve and 59 received trab. Primary open-angle glaucoma was primary diagnosis more often in trab, while neovascular glaucoma predominated in the valve group (p < 0.001). Preoperative mean IOP was 35.1 ± 11.8 and 24.5 ± 7.1 mm Hg for valve and trabeculectomy respectively (p < 0.001), but at 1 year the IOP difference between groups was not statistically significant (p = 0.064). Overall, 11 (25.0%) and 11 (18.6%) eyes met any criteria for failure for valve and trab respectively. At 1 year, 22.5% of valves had IOP > 21 mm Hg vs only 4.3% of trab (p = 0.02). Complications were infrequent. There were no intraoperative complications for valve, whereas five for trab. Most common immediate complication for valve was hyphema. Both groups had low rates of choroidal effusions and reoperation. Conclusion: Ahmed valve implantation and trabeculectomy produce significant reductions in IOP when performed by residents-in-training. Valves tend to be used more frequently in patients with secondary glaucoma. Although complication profiles differ between procedures, both are safe and well tolerated when performed by resident physicians. Clinical significance: This study provides support for evidence-based patient counseling that supervised, resident-performed Ahmed valve implantation and trabeculectomy are indeed safe and effective. How to cite this article: Sharpe RA, Kammerdiener LL, Wannamaker KW, Fan J, Sharpe ED. Comparison of Outcomes of Resident-performed Ahmed Valve Implantation vs Trabeculectomy. J Curr Glaucoma Pract 2016;10(2):60-67. PMID:27536049
Fazal, Iftikhar A; Alfakih, Khaled; Wilcox, Robert G; Walsh, John T
2009-05-01
Aortic stenosis (AS) is the most common indication for valve surgery. Recent data suggested an increased risk of cerebral emboli when the aortic valve is crossed to obtain 'pull-back' gradient. We conducted a large questionnaire based study to evaluate current practice in the assessment of aortic valve gradient amongst cardiologists and the preferences of cardiac surgeons in the UK. E-mail questionnaires were sent to 645 (72%) UK consultant cardiologists and to 198 (92%) UK consultant cardiac surgeons. 232 cardiologists and 52 cardiac surgeons responded. 53% of cardiologists routinely attempt to cross the valve in moderate AS while only 23% do so in severe AS. 38% of cardiologists in the age group '50+ years' cross the valve in severe AS compared to 13% in the age group '30-40 years'. Common reasons given for crossing a stenosed valve included 'to verify the echocardiographic gradient' (85%) and 'maintaining skill' (24%). 64% of cardiologists have changed their views on the necessity of crossing the valve in the last ten years. Although the majority appreciate the increased risk of crossing the valve only 18% of patients are consented differently if crossing the valve is planned. 26% of cardiac surgeons prefer the valve to be crossed to provide information on 'pull-back' gradient, 32% for LV function assessment and 14% to confirm MV competence. 92% would accept echocardiographic data alone if both the gradient and aortic valve area were available and considered correct. Our survey found that the practice of crossing the aortic valve has changed in the last 10 years and that younger consultant cardiologists are less likely to cross the aortic valve. Increasing confidence in echocardiographic data and potential complications of crossing the valve are implicated. 92% of cardiac surgeons do not require the valve to be crossed if the echo data is considered accurate.
Sierad, Leslie Neil; Shaw, Eliza Laine; Bina, Alexander; Brazile, Bryn; Rierson, Nicholas; Patnaik, Sourav S.; Kennamer, Allison; Odum, Rebekah; Cotoi, Ovidiu; Terezia, Preda; Branzaniuc, Klara; Smallwood, Harrison; Deac, Radu; Egyed, Imre; Pavai, Zoltan; Szanto, Annamaria; Harceaga, Lucian; Suciu, Horatiu; Raicea, Victor; Olah, Peter; Simionescu, Agneta; Liao, Jun; Movileanu, Ionela
2015-01-01
There is a great need for living valve replacements for patients of all ages. Such constructs could be built by tissue engineering, with perspective of the unique structure and biology of the aortic root. The aortic valve root is composed of several different tissues, and careful structural and functional consideration has to be given to each segment and component. Previous work has shown that immersion techniques are inadequate for whole-root decellularization, with the aortic wall segment being particularly resistant to decellularization. The aim of this study was to develop a differential pressure gradient perfusion system capable of being rigorous enough to decellularize the aortic root wall while gentle enough to preserve the integrity of the cusps. Fresh porcine aortic roots have been subjected to various regimens of perfusion decellularization using detergents and enzymes and results compared to immersion decellularized roots. Success criteria for evaluation of each root segment (cusp, muscle, sinus, wall) for decellularization completeness, tissue integrity, and valve functionality were defined using complementary methods of cell analysis (histology with nuclear and matrix stains and DNA analysis), biomechanics (biaxial and bending tests), and physiologic heart valve bioreactor testing (with advanced image analysis of open–close cycles and geometric orifice area measurement). Fully acellular porcine roots treated with the optimized method exhibited preserved macroscopic structures and microscopic matrix components, which translated into conserved anisotropic mechanical properties, including bending and excellent valve functionality when tested in aortic flow and pressure conditions. This study highlighted the importance of (1) adapting decellularization methods to specific target tissues, (2) combining several methods of cell analysis compared to relying solely on histology, (3) developing relevant valve-specific mechanical tests, and (4) in vitro testing of valve functionality. PMID:26467108
Earlier Pulmonary Valve Replacement in Down Syndrome Patients Following Tetralogy of Fallot Repair.
Sullivan, Rachel T; Frommelt, Peter C; Hill, Garick D
2017-08-01
The association between Down syndrome and pulmonary hypertension could contribute to more severe pulmonary regurgitation after tetralogy of Fallot repair and possibly earlier pulmonary valve replacement. We compared cardiac magnetic resonance measures of pulmonary regurgitation and right ventricular dilation as well as timing of pulmonary valve replacement between those with and without Down syndrome after tetralogy of Fallot repair. Review of our surgical database from 2000 to 2015 identified patients with tetralogy of Fallot with pulmonary stenosis. Those with Down syndrome were compared to those without. The primary outcome of interest was time from repair to pulmonary valve replacement. Secondary outcomes included pulmonary regurgitation and indexed right ventricular volume on cardiac magnetic resonance imaging. The cohort of 284 patients included 35 (12%) with Down syndrome. Transannular patch repair was performed in 210 (74%). Down syndrome showed greater degree of pulmonary regurgitation (55 ± 14 vs. 37 ± 16%, p = 0.01) without a significantly greater rate of right ventricular dilation (p = 0.09). In multivariable analysis, Down syndrome (HR 2.3, 95% CI 1.2-4.5, p = 0.02) and transannular patch repair (HR 5.5, 95% CI 1.7-17.6, p = 0.004) were significant risk factors for valve replacement. Those with Down syndrome had significantly lower freedom from valve replacement (p = 0.03). Down syndrome is associated with an increased degree of pulmonary regurgitation and earlier pulmonary valve replacement after tetralogy of Fallot repair. These patients require earlier assessment by cardiac magnetic resonance imaging to determine timing of pulmonary valve replacement and evaluation for and treatment of preventable causes of pulmonary hypertension.
Bozbas, Huseyin; Yildirir, Aylin; Demir, Ozlem; Cakmak, Abdulkadir; Karacaglar, Emir; Yilmaz, Mustafa; Eroglu, Serpil; Pirat, Bahar; Ozin, Bulent; Muderrisoglu, Haldun
2008-07-01
A growing body of data indicates an independent association between serum gamma-glutamyltransferase (GGT) activity, a marker of increased oxidative stress, and cardiovascular diseases. The process of calcific aortic valve disease has been shown to present characteristics of atherosclerosis. The study aim was to evaluate the possible role of serum GGT in patients with calcific aortic valve disease. The results of patients' echocardiography studies from 2005 for the presence of calcific aortic valve disease in the forms of aortic stenosis (AS) and aortic valve calcification (AVC) without significant valve stenosis, were retrospectively evaluated. Age-and gender-matched patients with normal aortic valve morphology were selected at random as a control group. A total of 383 patients was enrolled into the study (126 with AS, 133 with AVC, 124 controls). Serum GGT activity, along with other liver enzyme analyses and laboratory results, were determined and compared among the groups. Age, gender and clinical and laboratory results were similar among the three groups. Median serum GGT levels in the AS, AVC and control groups were 23.0 U/1 (mean 31.5 +/- 24.9 U/1), 22.0 U/1 (mean 27.6 +/- 18.6 U/) and 18.0 U/l (mean 22.4 +/- 16.4 U/l), respectively. Compared to controls, AS patients had significantly higher serum GGT and C-reactive protein levels, while the differences between AVC patients and controls for these parameters were not significant. The study results suggest that serum GGT activity is increased in patients with calcific AS. These increases seem to occur in advanced rather than milder forms of calcific aortic valve disease.
A thin film nitinol heart valve.
Stepan, Lenka L; Levi, Daniel S; Carman, Gregory P
2005-11-01
In order to create a less thrombogenic heart valve with improved longevity, a prosthetic heart valve was developed using thin film nitinol (NiTi). A "butterfly" valve was constructed using a single, elliptical piece of thin film NiTi and a scaffold made from Teflon tubing and NiTi wire. Flow tests and pressure readings across the valve were performed in vitro in a pulsatile flow loop. Bio-corrosion experiments were conducted on untreated and passivated thin film nitinol. To determine the material's in vivo biocompatibility, thin film nitinol was implanted in pigs using stents covered with thin film NiTi. Flow rates and pressure tracings across the valve were comparable to those through a commercially available 19 mm Perimount Edwards tissue valve. No signs of corrosion were present on thin film nitinol samples after immersion in Hank's solution for one month. Finally, organ and tissue samples explanted from four pigs at 2, 3, 4, and 6 weeks after thin film NiTi implantation appeared without disease, and the thin film nitinol itself was without thrombus formation. Although long term testing is still necessary, thin film NiTi may be very well suited for use in artificial heart valves.
Intraoperative echocardiographic detection of regurgitant jets after valve replacement
NASA Technical Reports Server (NTRS)
Morehead, A. J.; Firstenberg, M. S.; Shiota, T.; Qin, J.; Armstrong, G.; Cosgrove, D. M. 3rd; Thomas, J. D.
2000-01-01
BACKGROUND: Paravalvular jets, documented by intraoperative transesophageal echocardiography, have prompted immediate valve explantation by others, yet the significance of these jets is unknown. METHODS: Twenty-seven patients had intraoperative transesophageal two-dimensional color Doppler echocardiography, performed to assess the number and area of regurgitant jets after valve replacement, before and after protamine. Patients were grouped by first time versus redo operation, valve position and type. RESULTS: Before protamine, 55 jets were identified (2.04+/-1.4 per patient) versus 29 jets after (1.07+/-1.2 per patient, p = 0.0002). Total jet area improved from 2.0+/-2.2 cm2 to 0.86+/-1.7 cm2 with protamine (p<0.0001). In all patients jet area decreased (average decrease, 70.7%+/-27.0%). First time and redo operations had similar improvements in jet number and area (both p>0.6). Furthermore, mitral and mechanical valves each had more jets and overall greater jet area when compared to aortic and tissue valves, respectively. CONCLUSIONS: Following valve replacement, multiple jets are detected by intraoperative transesophageal echocardiography. They are more common and larger in the mitral position and with mechanical valves. Improvement occurs with reversal of anticoagulation.
Reversible thermo-pneumatic valves on centrifugal microfluidic platforms.
Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Harun, Sulaiman Wadi; Kazemzadeh, Amin; Rothan, Hussin A; Yusof, Rohana; Madou, Marc
2015-08-21
Centrifugal microfluidic systems utilize a conventional spindle motor to automate parallel biochemical assays on a single microfluidic disk. The integration of complex, sequential microfluidic procedures on these platforms relies on robust valving techniques that allow for the precise control and manipulation of fluid flow. The ability of valves to consistently return to their former conditions after each actuation plays a significant role in the real-time manipulation of fluidic operations. In this paper, we introduce an active valving technique that operates based on the deflection of a latex film with the potential for real-time flow manipulation in a wide range of operational spinning speeds. The reversible thermo-pneumatic valve (RTPV) seals or reopens an inlet when a trapped air volume is heated or cooled, respectively. The RTPV is a gas-impermeable valve composed of an air chamber enclosed by a latex membrane and a specially designed liquid transition chamber that enables the efficient usage of the applied thermal energy. Inputting thermo-pneumatic (TP) energy into the air chamber deflects the membrane into the liquid transition chamber against an inlet, sealing it and thus preventing fluid flow. From this point, a centrifugal pressure higher than the induced TP pressure in the air chamber reopens the fluid pathway. The behaviour of this newly introduced reversible valving system on a microfluidic disk is studied experimentally and theoretically over a range of rotational frequencies from 700 RPM to 2500 RPM. Furthermore, adding a physical component (e.g., a hemispherical rubber element) to induce initial flow resistance shifts the operational range of rotational frequencies of the RTPV to more than 6000 RPM. An analytical solution for the cooling of a heated RTPV on a spinning disk is also presented, which highlights the need for the future development of time-programmable RTPVs. Moreover, the reversibility and gas impermeability of the RTPV in the microfluidic networks are validated on a microfluidic disk designed for performing liquid circulation. Finally, an array of RTPVs is integrated into a microfluidic cartridge to enable sequential aliquoting for the conversion of dengue virus RNA to cDNA and the preparation of PCR reaction mixtures.
Capitanio, Jody Filippo; Venier, Alice; Mazzeo, Lucio Aniello; Barzaghi, Lina Raffaella; Acerno, Stefania; Mortini, Pietro
2016-04-01
Exposure to magnetic fields may alter the settings of programmable ventriculoperitoneal shunt valves or even cause permanent damages to these devices. There is little information about this topic, none on live patients. To investigate the effects of 1.5-tesla magnetic resonance imaging (MRI) on Hakim-Codman (HC) pressure programmable valves implanted in our hospital. A single-center prospective study to assess the rate of perturbations of HC programmable valve implanted. One hundred consecutive patients implanted for different clinical reasons between 2008 and 2012 were examined. A conventional skull x-ray before and after a standard MRI on 1.5 tesla. We evaluated before and after results, analyzed modification rate, and verified eventual damages to the implanted devices. Implanted HC valves are extremely handy and durable, even if they are likely to change often due to the exposure to magnetic fields. None of the patients complained of heating effects. Oscillations range from 10-30 mm H2O with a patient who reached 50 mm H2O and 1 who reached 60 mm H2O. Global alteration rate was 40%: 10 patients (10%) experienced a 10 mm H2O change; 14 patients (14%) had a 20 mm H2O change; 6 patients (6%) had a 30 mm H2O change; 8 patients (8%) had a 40 mm H2O change; 1 patient had a 50 mm H2O change; and 1 patient had a 60 mm H2O change. HC valves presented a variable perturbation rate, with an alteration rate of 40% with 1.5-telsa MRI. We have not observed malfunctioning hardware as a result of magnetic influence. We claim a cranial x-ray immediately after the MRI because of a high risk (40%) of decalibration, especially in patients with low ventricles compliance. Copyright © 2016 Elsevier Inc. All rights reserved.
Hemodynamics of physiological blood flow in the aorta with nonlinear anisotropic heart valve
NASA Astrophysics Data System (ADS)
Sotiropoulos, Fotis; Gilmanov, Anvar; Stolarski, Henryk
2016-11-01
The hemodynamic blood flow in cardiovascular system is one of the most important factor, which causing several vascular diseases. We developed a new Curvilinear Immersed Boundary - Finite Element - Fluid Structure Interaction (CURVIB-FE-FSI) method to analyze hemodynamic of pulsatile blood flow in a real aorta with nonlinear anisotropic aortic valve at physiological conditions. Hyperelastic material model, which is more realistic for describing heart valve have been incorporated in the CURVIB-FE-FSI code to simulate interaction of aortic heart valve with pulsatile blood flow. Comparative studies of hemodynamics for linear and nonlinear models of heart valve show drastic differences in blood flow patterns and hence differences of stresses causing impact at leaflets and aortic wall. This work is supported by the Lillehei Heart Institute at the University of Minnesota.
Heart sounds as a result of acoustic dipole radiation of heart valves
NASA Astrophysics Data System (ADS)
Kasoev, S. G.
2005-11-01
Heart sounds are associated with impulses of force acting on heart valves at the moment they close under the action of blood-pressure difference. A unified model for all the valves represents this impulse as an acoustic dipole. The near pressure field of this dipole creates a distribution of the normal velocity on the breast surface with features typical of auscultation practice: a pronounced localization of heart sound audibility areas, an individual area for each of the valves, and a noncoincidence of these areas with the projections of the valves onto the breast surface. In the framework of the dipole theory, the optimum size of the stethoscope’s bell is found and the spectrum of the heart sounds is estimated. The estimates are compared with the measured spectrum.
Contamination avoidance devices for poppettype shutoff valves
NASA Technical Reports Server (NTRS)
Endicott, D. L.
1973-01-01
The determination of the cycle life is reported of the scal closure of a typical poppet-type shutoff valve in an uncontaminated GH2 environment and then compared this component performance with simulated operation with GN2 and LN2 containing controlled amounts of AL2O3 contaminant particles. The original valve design was tested for contamination damage tolerance characteristics under full-flow and cyclic-operating conditions, redesigned to improve the damage tolerance to contaminants, and then retested. The redesigned valve was found to have acceptable tolerance characteristics under all full-flow conditions and cyclic operation with small (25-75 microns) particulate contamination. The tolerance characteristics of the valve under cyclic conditions with large (75-250 microns) particulate contamination was improved but was not found to be completely satisfactory.
Comparative durability and costs analysis of ventricular shunts.
Agarwal, Nitin; Kashkoush, Ahmed; McDowell, Michael M; Lariviere, William R; Ismail, Naveed; Friedlander, Robert M
2018-05-11
OBJECTIVE Ventricular shunt (VS) durability has been well studied in the pediatric population and in patients with normal pressure hydrocephalus; however, further evaluation in a more heterogeneous adult population is needed. This study aims to evaluate the effect of diagnosis and valve type-fixed versus programmable-on shunt durability and cost for placement of shunts in adult patients. METHODS The authors retrospectively reviewed the medical records of all patients who underwent implantation of a VS for hydrocephalus at their institution over a 3-year period between August 2013 and October 2016 with a minimum postoperative follow-up of 6 months. The primary outcome was shunt revision, which was defined as reoperation for any indication after the initial procedure. Supply costs, shunt durability, and hydrocephalus etiologies were compared between fixed and programmable valves. RESULTS A total of 417 patients underwent shunt placement during the index time frame, consisting of 62 fixed shunts (15%) and 355 programmable shunts (85%). The mean follow-up was 30 ± 12 (SD) months. The shunt revision rate was 22% for programmable pressure valves and 21% for fixed pressure valves (HR 1.1 [95% CI 0.6-1.8]). Shunt complications, such as valve failure, infection, and overdrainage, occurred with similar frequency across valve types. Kaplan-Meier survival curve analysis showed no difference in durability between fixed (mean 39 months) and programmable (mean 40 months) shunts (p = 0.980, log-rank test). The median shunt supply cost per index case and accounting for subsequent revisions was $3438 (interquartile range $2938-$3876) and $1504 (interquartile range $753-$1584) for programmable and fixed shunts, respectively (p < 0.001, Wilcoxon rank-sum test). Of all hydrocephalus etiologies, pseudotumor cerebri (HR 1.9 [95% CI 1.2-3.1]) and previous shunt malfunction (HR 1.8 [95% CI 1.2-2.7]) were found to significantly increase the risk of shunt revision. Within each diagnosis, there were no significant differences in revision rates between shunts with a fixed valve and shunts with a programmable valve. CONCLUSIONS Long-term shunt revision rates are similar for fixed and programmable shunt pressure valves in adult patients. Hydrocephalus etiology may play a significant role in predicting shunt revision, although programmable valves incur higher supply costs regardless of initial diagnosis. Utilization of fixed pressure valves versus programmable pressure valves may reduce supply costs while maintaining similar revision rates. Given the importance of developing cost-effective management protocols, this study highlights the critical need for large-scale prospective observational studies and randomized clinical trials of ventricular shunt valve revisions and additional patient-centered outcomes.
Fairbairn, Timothy A; Steadman, Christopher D; Mather, Adam N; Motwani, Manish; Blackman, Daniel J; Plein, Sven; McCann, Gerry P; Greenwood, John P
2013-01-01
Objective To compare the effects of transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) on aortic valve haemodynamics, ventricular reverse remodelling and myocardial fibrosis (MF) by cardiovascular magnetic resonance (CMR) imaging. Design A 1.5 T CMR scan was performed preoperatively and 6 months postoperatively. Setting University hospitals of Leeds and Leicester, UK. Patients 50 (25 TAVI, 25 SAVR; age 77±8 years) high-risk severe symptomatic aortic stenosis (AS) patients. Main outcome measures Valve haemodynamics, ventricular volumes, ejection fraction (EF), mass and MF. Results Patients were matched for gender and AS severity but not for age (80±6 vs 73±7 years, p=0.001) or EuroSCORE (22±14 vs 7±3, p<0.001). Aortic valve mean pressure gradient decreased to a greater degree post-TAVI compared to SAVR (21±8 mm Hg vs 35±13 mm Hg, p=0.017). Aortic regurgitation reduced by 8% in both groups, only reaching statistical significance for TAVI (p=0.003). TAVI and SAVR improved (p<0.05) left ventricular (LV) end-systolic volumes (46±18 ml/m2 vs 41±17 ml/m2; 44±22 ml/m2 vs32±6 ml/m2) and mass (83±20 g/m2 vs 65±15 g/m2; 74±11 g/m2 vs 59±8 g/m2). SAVR reduced end-diastolic volumes (92±19 ml/m2 vs 74±12 ml/m2, p<0.001) and TAVI increased EF (52±12% vs 56±10%, p=0.01). MF reduced post-TAVI (10.9±6% vs 8.5±5%, p=0.03) but not post-SAVR (4.2±2% vs 4.1±2%, p=0.98). Myocardial scar (p≤0.01) and baseline ventricular volumes (p<0.001) were the major predictors of reverse remodelling. Conclusions TAVI was comparable to SAVR at LV reverse remodelling and superior at reducing the valvular pressure gradient and MF. Future work should assess the prognostic importance of reverse remodelling and fibrosis post-TAVI to aid patient selection. PMID:23749779
An in vitro experimental study of flow past aortic valve under varied pulsatile conditions
NASA Astrophysics Data System (ADS)
Zhang, Ruihang; Zhang, Yan
2017-11-01
Flow past aortic valve represents a complex fluid-structure interaction phenomenon that involves pulsatile, vortical, and turbulent conditions. The flow characteristics immediately downstream of the valve, such as the variation of pulsatile flow velocity, formation of vortices, distribution of shear stresses, are of particular interest to further elucidate the role of hemodynamics in various aortic diseases. However, the fluid dynamics of a realistic aortic valve is not fully understood. Particularly, it is unclear how the flow fields downstream of the aortic valve would change under varied pulsatile inlet boundary conditions. In this study, an in vitro experiment has been conducted to investigate the flow fields downstream of a silicone aortic valve model within a cardiovascular flow simulator. Phased-locked Particle Image Velocimetry measurements were performed to map the velocity fields and Reynolds normal and shear stresses at different phases in a cardiac cycle. Temporal variations of pressure across the valve model were measured using high frequency transducers. Results have been compared for different pulsatile inlet conditions, including varied frequencies (heart rates), magnitudes (stroke volumes), and cardiac contractile functions (shapes of waveforms).
Unsteady Analyses of Valve Systems in Rocket Engine Testing Environments
NASA Technical Reports Server (NTRS)
Shipman, Jeremy; Hosangadi, Ashvin; Ahuja, Vineet
2004-01-01
This paper discusses simulation technology used to support the testing of rocket propulsion systems by performing high fidelity analyses of feed system components. A generalized multi-element framework has been used to perform simulations of control valve systems. This framework provides the flexibility to resolve the structural and functional complexities typically associated with valve-based high pressure feed systems that are difficult to deal with using traditional Computational Fluid Dynamics (CFD) methods. In order to validate this framework for control valve systems, results are presented for simulations of a cryogenic control valve at various plug settings and compared to both experimental data and simulation results obtained at NASA Stennis Space Center. A detailed unsteady analysis has also been performed for a pressure regulator type control valve used to support rocket engine and component testing at Stennis Space Center. The transient simulation captures the onset of a modal instability that has been observed in the operation of the valve. A discussion of the flow physics responsible for the instability and a prediction of the dominant modes associated with the fluctuations is presented.
Pressure Regulators as Valves for Saving Compressed Air and their Influence on System Dynamics
NASA Astrophysics Data System (ADS)
Dvořák, Lukáš; Fojtášek, Kamil
2015-05-01
Pressure regulators in the field of pneumatic mechanisms can be used as valves for saving compressed air. For example it can be used to reduce the pressure when the piston rod is retracting unloaded and thus it is possible to save some energy. However the problem is that saving valve can significantly affect the dynamics of the pneumatic system. The lower pressure in the piston rod chamber causes extension of time for retraction of the piston rod. This article compare the air consumption experimentally determined and calculated, measured curves of pressure in cylinder chambers and piston speed when saving valve is set up differently.
Analysis of pressure losses in the diffuser of a control valve
NASA Astrophysics Data System (ADS)
Turecký, Petr; Mrózek, Lukáš; Tajč, Ladislav; Kolovratník, Michal
The pressure loss in the diffuser of a control valve is evaluated by using CFD computations. Pressure ratios and lifts of a cone for the recommended flow characteristics of an experimental turbine are considered. The pressure loss in a valve is compared with the pressure loss in a nozzle, i.e. the embodiment of the valve without a cone. Computations are carried out for the same mass flow. Velocity profiles are evaluated in both versions of computations. Comparison of computed pressure losses, with the loss evaluated by using relations for diffusers with the ideal velocity conditions in the input cross-section, is carried out.
Rosa, Benoit; Machaidze, Zurab; Shin, Borami; Manjila, Sunil; Brown, David W; Baird, Christopher W; Mayer, John E; Dupont, Pierre E
2017-11-01
This paper provides detailed instructions for constructing low-cost bioprosthetic semilunar valves for animal research and clinical training. This work fills an important gap between existing simulator training valves and clinical valves by providing fully functioning designs that can be employed in ex vivo and in vivo experiments and can also be modified to model valvular disease. Valves are constructed in 4 steps consisting of creating a metal frame, covering it with fabric and attaching a suture ring and leaflets. Computer-aided design files are provided for making the frame from wire or by metal 3D printing. The covering fabric and suturing ring are made from materials readily available in a surgical lab, while the leaflets are made from pericardium. The entire fabrication process is described in figures and in a video. To demonstrate disease modelling, design modifications are described for producing paravalvular leaks, and these valves were evaluated in porcine ex vivo (n = 3) and in vivo (n = 6) experiments. Porcine ex vivo and acute in vivo experiments demonstrate that the valves can replicate the performance of clinical valves for research and training purposes. Surgical implantation is similar, and echocardiograms are comparable to clinical valves. Furthermore, valve leaflet function was satisfactory during acute in vivo tests with little central regurgitation, while the paravalvular leak modifications consistently produced leaks in the desired locations. The detailed design procedure presented here, which includes a tutorial video and computer-aided design files, should be of substantial benefit to researchers developing valve disease models and to clinicians developing realistic valve training systems. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
2011-01-01
Background Valve dysfunction is a common cardiovascular pathology. Despite significant clinical research, there is little formal study of how valve dysfunction affects overall circulatory dynamics. Validated models would offer the ability to better understand these dynamics and thus optimize diagnosis, as well as surgical and other interventions. Methods A cardiovascular and circulatory system (CVS) model has already been validated in silico, and in several animal model studies. It accounts for valve dynamics using Heaviside functions to simulate a physiologically accurate "open on pressure, close on flow" law. However, it does not consider real-time valve opening dynamics and therefore does not fully capture valve dysfunction, particularly where the dysfunction involves partial closure. This research describes an updated version of this previous closed-loop CVS model that includes the progressive opening of the mitral valve, and is defined over the full cardiac cycle. Results Simulations of the cardiovascular system with healthy mitral valve are performed, and, the global hemodynamic behaviour is studied compared with previously validated results. The error between resulting pressure-volume (PV) loops of already validated CVS model and the new CVS model that includes the progressive opening of the mitral valve is assessed and remains within typical measurement error and variability. Simulations of ischemic mitral insufficiency are also performed. Pressure-Volume loops, transmitral flow evolution and mitral valve aperture area evolution follow reported measurements in shape, amplitude and trends. Conclusions The resulting cardiovascular system model including mitral valve dynamics provides a foundation for clinical validation and the study of valvular dysfunction in vivo. The overall models and results could readily be generalised to other cardiac valves. PMID:21942971
Yu, Pey-Jen; Mattia, Allan; Cassiere, Hugh A; Esposito, Rick; Manetta, Frank; Kohn, Nina; Hartman, Alan R
2017-12-29
Significant mitral regurgitation in patients undergoing transcatheter aortic valve replacement (TAVR) is associated with increased mortality. The aim of this study is to determine if surgical correction of both aortic and mitral valves in high risk patients with concomitant valvular disease would offer patients better outcomes than TAVR alone. A retrospective analysis of 43 high-risk patients who underwent concomitant surgical aortic valve replacement and mitral valve surgery from 2008 to 2012 was performed. Immediate and long term survival were assessed. There were 43 high-risk patients with severe aortic stenosis undergoing concomitant surgical aortic valve replacement and mitral valve surgery. The average age was 80 ± 6 years old. Nineteen (44%) patients had prior cardiac surgery, 15 (34.9%) patients had chronic obstructive lung disease, and 39 (91%) patients were in congestive heart failure. The mean Society of Thoracic Surgeons Predicted Risk of Mortality for isolated surgical aortic valve replacement for the cohort was 10.1% ± 6.4%. Five patients (11.6%) died during the index admission and/or within thirty days of surgery. Mortality rate was 25% at six months, 35% at 1 year and 45% at 2 years. There was no correlation between individual preoperative risk factors and mortality. High-risk patients with severe aortic stenosis and mitral valve disease undergoing concomitant surgical aortic valve replacement and mitral valve surgery may have similar long term survival as that described for such patients undergoing TAVR. Surgical correction of double valvular disease in this patient population may not confer mortality benefit compared to TAVR alone.
NASA Astrophysics Data System (ADS)
Rahbar, Mona; Shannon, Lesley; Gray, Bonnie L.
2016-05-01
We present a new magnetically actuated microfluidic valve that employs a highly magnetic composite polymer (M-CP) containing rare-earth hard-magnetic powder for its actuating element and for its valve seat. The M-CP offers much higher magnetization compared to the soft-magnetic, ferrite-based composite polymers typically used in microfluidic applications. Each valve consists of a permanently magnetized M-CP flap and valve seat mounted on a microfluidic channel system fabricated in poly(dimethylsiloxane) (PDMS). Each valve is actuated under a relatively small external magnetic field of 80 mT provided by a small permanent magnet mounted on a miniature linear actuator. The performance of the valve with different flap thicknesses is characterized. In addition, the effect of the magnetic valve seat on the valve’s performance is also characterized. It is experimentally shown that a valve with a 2.3 mm flap thickness, actuated under an 80 mT magnetic field, is capable of completely blocking liquid flow at a flow rate of 1 ml min-1 for pressures up to 9.65 kPa in microfluidic channels 200 μm wide and 200 μm deep. The valve can also be fabricated into an array for flow switching between multiple microfluidic channels under continuous flow conditions. The performance of arrays of valves for flow routing is demonstrated for flow rates up to 5 ml min-1 with larger microfluidic channels of up to 1 mm wide and 500 μm deep. The design of the valves is compatible with other commonly used polymeric microfluidic components, as well as other components that use the same novel permanently magnetic composite polymer, such as our previously reported cilia-based mixing devices.
Broad-Range 16S rDNA PCR on Heart Valves in Infective Endocarditis.
Müller Premru, Manica; Lejko Zupanc, Tatjana; Klokočovnik, Tomislav; Ruzić Sabljić, Eva; Cerar, Tjaša
2016-03-01
Infective endocarditis (IE) is diagnosed by blood and/or resected valve cultivation and echocardiographic findings, as defined by the Duke criteria. Unfortunately, cultures may be negative due to prior antibiotic therapy or fastidious or slow-growing microorganisms. The study aim was to investigate the value of the broad-range polymerase chain reaction (PCR) in addition to blood and valve culture for the detection of causative microorganisms. Between February 2012 and March 2015, valve samples from 36 patients undergoing cardiac surgery were analyzed; of these patients, 26 had a preoperative diagnosis of IE and 10 served as controls. Multiple blood cultures were obtained from 34 patients before antibiotic therapy was commenced. Valve samples were inoculated on bacteriological media and underwent analysis using broad-range PCR (16S rDNA). IE was confirmed microbiologically in 21 of the 26 patients (80.7%); in 20 cases (76.9%) this was by positive blood cultures and in 16 (61.5%) by positive valves. Valves were positive in 15 blood culturepositive patients, and in one blood-culture negative patient. Broad-range PCR detected a microorganism in valves significantly more frequently (n = 14; 53.8%) compared to valve culture (n = 8; 30.7%) (chisquare 11.5, p <0.001). The predominant microorganisms were Staphylococcus aureus, Streptococcus of the viridans group, coagulasenegative staphylococci and Enterococcus faecalis. Blood, valve cultures and broad-range PCR were negative in five patients (19.3%) with IE, and in all 10 subjects of the control group. Broad-range PCR on valves was more sensitive than valve culture. However, blood culture, if taken before the start of antibiotic therapy, was the best method for detecting IE.
Desai, Ravi R; Vargas Abello, Lina Maria; Klein, Allan L; Marwick, Thomas H; Krasuski, Richard A; Ye, Ying; Nowicki, Edward R; Rajeswaran, Jeevanantham; Blackstone, Eugene H; Pettersson, Gösta B
2013-11-01
To study the effect of mitral valve repair with or without concomitant tricuspid valve repair on functional tricuspid regurgitation and right ventricular function. From 2001 to 2007, 1833 patients with degenerative mitral valve disease, a structurally normal tricuspid valve, and no coronary artery disease underwent mitral valve repair, and 67 underwent concomitant tricuspid valve repair. Right ventricular function (myocardial performance index and tricuspid annular plane systolic excursion) was measured before and after surgery using transthoracic echocardiography for randomly selected patients with tricuspid regurgitation grade 0, 1+, and 2+ (100 patients for each grade) and 93 with grade 3+/4+, 393 patients in total. In patients with mild (<3+) preoperative tricuspid regurgitation, mitral valve repair alone was associated with reduced tricuspid regurgitation and mild worsening of right ventricular function. Tricuspid regurgitation of 2+ or greater developed in fewer than 20%, and right ventricular function had improved, but not to preoperative levels, at 3 years. In patients with severe (3+/4+) preoperative tricuspid regurgitation, mitral valve repair alone reduced tricuspid regurgitation and improved right ventricular function; however, tricuspid regurgitation of 2+ or greater returned and right ventricular function worsened toward preoperative levels within 3 years. Concomitant tricuspid valve repair effectively eliminated severe tricuspid regurgitation and improved right ventricular function. Also, over time, tricuspid regurgitation did not return and right ventricular function continued to improve to levels comparable to that of patients with lower grades of preoperative tricuspid regurgitation. In patients with mitral valve disease and severe tricuspid regurgitation, mitral valve repair alone was associated with improved tricuspid regurgitation and right ventricular function. However, the improvements were incomplete and temporary. In contrast, concomitant tricuspid valve repair effectively and durably eliminated severe tricuspid regurgitation and improved right ventricular function toward normal, supporting an aggressive approach to important functional tricuspid regurgitation. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Desai, Ravi R.; Vargas Abello, Lina Maria; Klein, Allan L.; Marwick, Thomas H.; Krasuski, Richard A.; Ye, Ying; Nowicki, Edward R.; Rajeswaran, Jeevanantham; Blackstone, Eugene H.; Pettersson, Gösta B.
2014-01-01
Objectives To study the effect of mitral valve repair with or without concomitant tricuspid valve repair on functional tricuspid regurgitation and right ventricular function. Methods From 2001 to 2007, 1833 patients with degenerative mitral valve disease, a structurally normal tricuspid valve, and no coronary artery disease underwent mitral valve repair, and 67 underwent concomitant tricuspid valve repair. Right ventricular function (myocardial performance index and tricuspid annular plane systolic excursion) was measured before and after surgery using transthoracic echocardiography for randomly selected patients with tricuspid regurgitation grade 0, 1+, and 2+(100 patients for each grade) and 93 with grade 3+/4+, 393 patients in total. Results In patients with mild (<3+) preoperative tricuspid regurgitation, mitral valve repair alone was associated with reduced tricuspid regurgitation and mild worsening of right ventricular function. Tricuspid regurgitation of 2+or greater developed in fewer than 20%, and right ventricular function had improved, but not to preoperative levels, at 3 years. In patients with severe (3+/4+) preoperative tricuspid regurgitation, mitral valve repair alone reduced tricuspid regurgitation and improved right ventricular function; however, tricuspid regurgitation of 2+ or greater returned and right ventricular function worsened toward preoperative levels within 3 years. Concomitant tricuspid valve repair effectively eliminated severe tricuspid regurgitation and improved right ventricular function. Also, over time, tricuspid regurgitation did not return and right ventricular function continued to improve to levels comparable to that of patients with lower grades of preoperative tricuspid regurgitation. Conclusions In patients with mitral valve disease and severe tricuspid regurgitation, mitral valve repair alone was associated with improved tricuspid regurgitation and right ventricular function. However, the improvements were incomplete and temporary. In contrast, concomitant tricuspid valve repair effectively and durably eliminated severe tricuspid regurgitation and improved right ventricular function toward normal, supporting an aggressive approach to important functional tricuspid regurgitation. PMID:23010580
Hockaday, L A; Kang, K H; Colangelo, N W; Cheung, P Y C; Duan, B; Malone, E; Wu, J; Girardi, L N; Bonassar, L J; Lipson, H; Chu, C C; Butcher, J T
2013-01-01
The aortic valve exhibits complex three-dimensional (3D) anatomy and heterogeneity essential for long-term efficient biomechanical function. These are, however, challenging to mimic in de novo engineered living tissue valve strategies. We present a novel simultaneous 3D-printing/photocrosslinking technique for rapidly engineering complex, heterogeneous aortic valve scaffolds. Native anatomic and axisymmetric aortic valve geometries (root wall and tri-leaflets) with 12 to 22 mm inner diameters (ID) were 3D printed with poly-ethylene glycol-diacrylate (PEG-DA) hydrogels (700 or 8000 MW) supplemented with alginate. 3D printing geometric accuracy was quantified and compared using Micro-CT. Porcine aortic valve interstitial cells (PAVIC) seeded scaffolds were cultured for up to 21 days. Results showed that blended PEG-DA scaffolds could achieve over 10-fold range in elastic modulus (5.3±0.9 to 74.6±1.5 kPa). 3D printing times for valve conduits with mechanically contrasting hydrogels were optimized to 14 to 45 minutes, increasing linearly with conduit diameter. Larger printed valves had greater shape fidelity (93.3±2.6, 85.1±2.0, and 73.3±5.2% for 22, 17, and 12 mm ID porcine valves; 89.1±4.0, 84.1±5.6, and 66.6±5.2% for simplified valves). PAVIC seeded scaffolds maintained near 100% viability over 21 days. These results demonstrate that 3D hydrogel printing with controlled photocrosslinking can rapidly fabricate anatomical heterogeneous valve conduits that support cell engraftment. PMID:22914604
Lubiński, Wojciech; Krzystolik, Karol; Gosławski, Wojciech; Kuprjanowicz, Leszek; Mularczyk, Maciej
2018-01-01
Inflammation associated with biomaterials of Ahmed® glaucoma drainage devices may cause the formation of a capsule around the device and can thus have a significant influence on the level of intraocular pressure reduction. The objective of this study was to compare the clinical outcomes after the implantation of a polypropylene or silicone Ahmed® glaucoma valve in patients with neovascular glaucoma. In the study, 27 eyes with neovascular glaucoma (group 1) received silicon Ahmed® valves and 23 eyes (group 2) received polypropylene valves. The best corrected distance visual acuity (BCDVA), intraocular pressure (IOP) and number of anti-glaucomatous drugs were recorded preoperatively and during a follow-up period of 24 months after surgery. Success was defined by the following criteria: 1) intraocular pressure in the rage of 6-21 mm Hg; 2) IOP reduction of at least 30% relative to preoperative values. All complications were registered. One month postoperatively, the mean BCDVA increased significantly in both groups compared to preoperative values (p < 0.001). These values did not change during the 24 months of follow-up examinations. The probability of success defined by criterion 1 at 24 months of observation was 66.7% for silicone and 27.3% for propylene valves group (p < 0.007). According to criterion 2, the difference in success between the groups was not statistically significant. The total number of complications that occurred in both groups during the 24 months of follow-up examinations was similar, except for a higher occurrence of Tenon's cyst formation in the group with a polypropylene valve (18% vs 35%; p < 0.04). In patients with neovascular glaucoma, the implantation of a silicone valve is associated with a significantly higher probability of long-term reduction of IOP below 21 mm Hg and with a lower risk of valve encapsulation in comparison to polypropylene valves. The obtained results suggest that silicone Ahmed® valves are more effective in the treatment of patients with neovascular glaucoma.
Pendyala, Lakshmana K; Minha, Sa'ar; Barbash, Israel M; Torguson, Rebecca; Magalhaes, Marco A; Okubagzi, Petros; Loh, Joshua P; Chen, Fang; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron
2014-01-15
In patients with aortic stenosis who cannot have surgery, transcatheter aortic valve replacement using the Edwards SAPIEN valve has been shown to improve survival rate and is approved for commercial use in the United States. This study aims to assess the clinical profile, procedural characteristics, and in-hospital complications in patients treated with a commercial SAPIEN valve outside the clinical trial context. We retrospectively analyzed 69 consecutive patients who underwent transcatheter aortic valve replacement with a commercial SAPIEN valve compared with 55 Placement of AoRTic traNscathetER valves (PARTNER) trial patients from cohort B enrolled in the same institution by the same Heart Team. Compared with the commercial group, patients in the PARTNER cohort B had higher mean Society of Thoracic Surgeons score (10 ± 5 vs 9 ± 4, p = 0.04) and a lower rate of peripheral arterial disease (19% vs 44%, p = 0.004). Most patients in the commercial group had the procedure under conscious sedation (83% vs 66%, p = 0.03). Planned surgical cut down for vascular access was rare in the commercial group (1.4% vs 46%, p <0.001). The overall rates of major vascular complications, life-threatening or major bleeding, and blood transfusions were lower in commercial group (7.2% vs 27%, p = 0.003; 2.9% vs 16%, p = 0.01; and 28% vs 60%, p <0.001, respectively). In-hospital all-cause mortality (5.8% vs 9.1%, p = 0.51) and stroke rates (7.2% vs 14.5%, p = 0.19) were not statistically different between groups. The median length of hospitalization (p <0.001) and postprocedural length of stay (p = 0.01) was shorter in the commercial group. In conclusion, transfemoral commercial use of the Edwards SAPIEN valve for inoperable patients shows similar in-hospital mortality and stroke rates compared with PARTNER cohort B. The refinements in the procedure such as more conscious sedation, experience of the operators, and careful vascular planning in the commercial group led to lesser vascular and bleeding complications and shorter length of stay. Copyright © 2014 Elsevier Inc. All rights reserved.
Echocardiographic versus histologic findings in Marfan syndrome.
Gu, Xiaoyan; He, Yihua; Li, Zhian; Han, Jiancheng; Chen, Jian; Nixon, J V Ian
2015-02-01
This retrospective study attempted to establish the prevalence of multiple-valve involvement in Marfan syndrome and to compare echocardiographic with histopathologic findings in Marfan patients undergoing valvular or aortic surgery. We reviewed echocardiograms of 73 Marfan patients who underwent cardiovascular surgery from January 2004 through October 2009. Tissue histology was available for comparison in 29 patients. Among the 73 patients, 66 underwent aortic valve replacement or the Bentall procedure. Histologic findings were available in 29 patients, all of whom had myxomatous degeneration. Of 63 patients with moderate or severe aortic regurgitation as determined by echocardiography, 4 had thickened aortic valves. The echocardiographic findings in 18 patients with mitral involvement included mitral prolapse in 15. Of 11 patients with moderate or severe mitral regurgitation as determined by echocardiography, 4 underwent mitral valve repair and 7 mitral valve replacement. Histologic findings among mitral valve replacement patients showed thickened valve tissue and myxomatous degeneration. Tricuspid involvement was seen echocardiographically in 8 patients, all of whom had tricuspid prolapse. Two patients had severe tricuspid regurgitation, and both underwent repair. Both mitral and tricuspid involvement were seen echocardiographically in 7 patients. Among the 73 patients undergoing cardiac surgery for Marfan syndrome, 66 had moderate or severe aortic regurgitation, although their valves manifested few histologic changes. Eighteen patients had mitral involvement (moderate or severe mitral regurgitation, prolapse, or both), and 8 had tricuspid involvement. Mitral valves were most frequently found to have histologic changes, but the tricuspid valve was invariably involved.
Fujii, Yoko; Orito, Kensuke; Muto, Makoto; Wakao, Yoshito
2007-10-01
To investigate whether the tissue and plasma renin-angiotensin-aldosterone system (RAAS) is activated in dogs with mild regurgitation through the mitral valve and determine the contribution of chymase and angiotensin-converting enzyme (ACE) to the activation of the RAAS and potential production of angiotensin II during the chronic stage of mild mitral valve regurgitation. 5 Beagles with experimentally induced mild mitral valve regurgitation and 6 clinically normal (control) Beagles. Tissue ACE and chymase-like activities and plasma RAAS were measured and the RAAS evaluated approximately 1,000 days after experimental induction of mitral valve regurgitation in the 5 dogs. Dogs with experimentally induced mitral valve regurgitation did not have clinical signs of the condition, although echocardiography revealed substantial eccentric hyper- trophy. On the basis of these findings, dogs with mitral valve regurgitation were classified as International Small Animal Cardiac Health Council class Ib. Plasma activity of renin and plasma concentrations of angiotensin I, angiotensin II, and aldosterone were not significantly different between dogs with mitral valve regurgitation and clinically normal dogs. Tissue ACE activity was significantly increased and chymase-like activity significantly decreased in dogs with mitral valve regurgitation, compared with values in clinically normal dogs. The tissue RAAS was modulated without changes in the plasma RAAS in dogs with mild mitral valve regurgitation during the chronic stage of the condition. An ACE-dependent pathway may be a major route for production of angiotensin II during this stage of the condition.
Sakamoto, Yoshimasa; Hashimoto, Kazuhiro; Okuyama, Hiroshi; Ishii, Shinichi; Shingo, Taguchi; Kagawa, Hiroshi
2006-01-01
Pannus formation after aortic valve replacement is not common, but obstruction due to chronic pannus is one of the most serious complications of valve replacement. The causes of pannus formation are still unknown and effective preventive methods have not been fully elucidated. We reviewed our clinical experience of all patients who underwent reoperation for prosthetic aortic valve obstruction due to pannus formation between 1973 and 2004. We compared the initial 18-year period of surgery, when the Björk-Shiley tilting-disk valve was used, and the subsequent 13-year period of surgery, when the St. Jude Medical valve was used. Seven of a total of 390 patients (1.8%) required reoperation for prosthetic aortic valve obstruction due to pannus formation. All seven patients were women; four patients underwent resection of the pannus and three patients needed replacement of the valve. The frequency of pannus formation in the early group was 2.4% (6/253), whereas it was 0.73% (1/137) in the late group (P < 0.05). Pannus was localized at the minor orifice of the Björk-Shiley valve in the early group and turbulent transvalvular blood flow was considered to be one of the important factors triggering its growth. We also consider that small bileaflet valves have the possibility of promoting pannus formation and that the implantation of a larger prosthesis can contribute to reducing the occurrence of pannus.
Rocha, Natalia P; Bastos, Fernando M; Vieira, Érica L M; Prestes, Thiago R R; Silveira, Katia D da; Teixeira, Mauro M; Simões E Silva, Ana Cristina
2018-03-11
Posterior urethral valve is the most common lower urinary tract obstruction in male children. A high percentage of patients with posterior urethral valve evolve to end-stage renal disease. Previous studies showed that cytokines, chemokines, and components of the renin-angiotensin system contribute to the renal damage in obstructive uropathies. The authors recently found that urine samples from fetuses with posterior urethral valve have increased levels of inflammatory molecules. The aim of this study was to measure renin-angiotensin system molecules and to investigate their correlation with previously detected inflammatory markers in the same urine samples of fetuses with posterior urethral valve. Urine samples from 24 fetuses with posterior urethral valve were collected and compared to those from 22 healthy male newborns at the same gestational age (controls). Renin-angiotensin system components levels were measured by enzyme-linked immunosorbent assay. Fetuses with posterior urethral valve presented increased urinary levels of angiotensin (Ang) I, Ang-(1-7) and angiotensin-converting enzyme 2 in comparison with controls. ACE levels were significantly reduced and Ang II levels were similar in fetuses with posterior urethral valve in comparison with controls. Increased urinary levels of angiotensin-converting enzyme 2 and of Ang-(1-7) in fetuses with posterior urethral valve could represent a regulatory response to the intense inflammatory process triggered by posterior urethral valve. Copyright © 2018 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.
Farmer, Joseph C.
2015-07-28
A solar-powered adsorption-desorption refrigeration and air conditioning system that uses nanostructural materials such as aerogels, zeolites, and sol gels as the adsorptive media. Refrigerant molecules are adsorbed on the high surface area of the nanostructural material while the material is at a relatively low temperature, perhaps at night. During daylight hours, when the nanostructural materials is heated by the sun, the refrigerant are thermally desorbed from the surface of the aerogel, thereby creating a pressurized gas phase in the vessel that contains the aerogel. This solar-driven pressurization forces the heated gaseous refrigerant through a condenser, followed by an expansion valve. In the condenser, heat is removed from the refrigerant, first by circulating air or water. Eventually, the cooled gaseous refrigerant expands isenthalpically through a throttle valve into an evaporator, in a fashion similar to that in more conventional vapor recompression systems.
Nonreciprocity of electrically excited thermal spin signals in CoFeAl-Cu-Py lateral spin valves
NASA Astrophysics Data System (ADS)
Hu, Shaojie; Cui, Xiaomin; Nomura, Tatsuya; Min, Tai; Kimura, Takashi
2017-03-01
Electrical and thermal spin currents excited by an electric current have been systematically investigated in lateral spin valves consisting of CoFeAl and Ni80Fe20 (Py) wires bridged by a Cu strip. In the electrical spin signal, the reciprocity between the current and voltage probes was clearly confirmed. However, a significant nonreciprocity was observed in the thermal spin signal. This provides clear evidence that a large spin-dependent Seebeck coefficient is more important than the spin polarization for efficient thermal spin injection and detection. We demonstrate that the spin-dependent Seebeck coefficient can be simply evaluated from the thermal spin signals for two configurations. Our experimental description paves a way for evaluating a small spin-dependent Seebeck coefficient for conventional ferromagnets without using complicated parameters.
Durability of hand-sewn valves in the right ventricular outlet.
Nunn, Graham R; Bennetts, Jayme; Onikul, Ella
2008-08-01
The objective was to compare the medium- and long-term outcomes for pericardial monocusp valves, polytetrafluoroethylene (Gore-Tex, WL Gore and Associates Inc, Flagstaff, Ariz) 0.1-mm monocusp valves, and bileaflet 0.l-mm polytetrafluoroethylene valves and their efficiency in the right ventricular outlet. We reviewed all hand-sewn right ventricular outlet valves created by the author (Graham R. Nunn) in the setting of repaired tetralogy of Fallot or equivalent right ventricular outlet pathology when the native pulmonary valve could not be preserved. The valves were assessed by serial transthoracic echocardiography and more recently by magnetic resonance imaging angiography for late valve function. The bileaflet polytetrafluoroethylene valves were constructed in a standardized fashion from a semicircle of 0.1-mm polytetrafluoroethylene (the radius of which equaled the length of the outflow tract incision) that gave a lengthened free edge to the leaflets, central fixation of the free edge posteriorly just proximal to the branch pulmonary arteries, and generous augmentation of the outflow tract with polytetrafluoroethylene patch-plasty. The bileaflet configuration shortens the closing time against the posterior wall, and the leaflets are forced to maintain their configuration without prolapse into the right ventricular outlet. The valve can be generously oversized in young children to try to avoid the need for replacement. A total of 54 patients met the selection criteria--22 patients received fresh autologous pericardial monocusps, 7 patients received polytetrafluoroethylene (0.1-mm) monocusps, and 25 patients received bileaflet polytetrafluoroethylene (0.1-mm) outlet valves. The pericardial valves have the longest follow-up, and all valves developed free pulmonary incompetence. Polytetrafluoroethylene monocusps had reliable competence early after surgery but progressed to pulmonary incompetence. The bileaflet polytetrafluoroethylene (0.1-mm) valves have remained competent with regurgitant fractions of only 5% to 30% (magnetic resonance imaging angiography), and this has remained stable with time. The maximum follow-up for these valves is 5 years. No stenosis or peripheral emboli have been recognized, and no valves have been replaced to date. Hand-sewn bileaflet polytetrafluoroethylene valves in the right ventricular outlet can reliably provide competence and maintain function in the medium term. Their shape and size allow placement in young children with a reasonable expectation that they will remain competent with growth of the native annulus and not require replacement. Their durability is superior to the pericardial and polytetrafluoroethylene monocusp valves in this series.
Apparatus and method for non-invasive diagnosis and control of motor operated valve condition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lyon, R.H.; Chai, J.; Lang, J.H.
1997-01-14
An apparatus compares the torque from an MOV motor with the valve displacement, and from the comparison assesses MOV operating condition. A transducer measures the vibration of the housing of an MOV. The vibrations are due to the motions of the rotating elements within the housing, which motions are directly related to the motion of the valve relative to its seat. Signal processing apparatus analyzes the vibrations to recover the rotations of the rotating elements and thus the motion of the valve plug. Lost motion can also be determined (if a lost motion connection exists) by demodulating the vibration signalmore » and thus taking into account also the lost motion. Simultaneously, the forces applied to the valve are estimated by estimating the torque between the stator and the rotor of the motor. Such torque can be estimated from measuring the input current and voltage alone, using a forgetting factor and a correction for the forgetting factor. A signature derived from relating the torque to the valve position can be used to assess the condition of the MOV, by comparing the signature to signatures for MOVs of known conditions. The vibration analysis components generate signals that relate to the position of elements in the operator. Similarly, the torque estimator estimates the torque output by any type of electric motor, whether or not part of an MOV analysis unit. 28 figs.« less
Apparatus and method for non-invasive diagnosis and control of motor operated valve condition
Lyon, R.H.; Chai, J.; Lang, J.H.; Hagman, W.H.; Umans, S.D.; Saarela, O.J.
1997-01-14
An apparatus compares the torque from an MOV motor with the valve displacement, and from the comparison assesses MOV operating condition. A transducer measures the vibration of the housing of an MOV. The vibrations are due to the motions of the rotating elements within the housing, which motions are directly related to the motion of the valve relative to its seat. Signal processing apparatus analyzes the vibrations to recover the rotations of the rotating elements and thus the motion of the valve plug. Lost motion can also be determined (if a lost motion connection exists) by demodulating the vibration signal and thus taking into account also the lost motion. Simultaneously, the forces applied to the valve are estimated by estimating the torque between the stator and the rotor of the motor. Such torque can be estimated from measuring the input current and voltage alone, using a forgetting factor and a correction for the forgetting factor. A signature derived from relating the torque to the valve position can be used to assess the condition of the MOV, by comparing the signature to signatures for MOVs of known conditions. The vibration analysis components generate signals that relate to the position of elements in the operator. Similarly, the torque estimator estimates the torque output by any type of electric motor, whether or not part of an MOV analysis unit. 28 figs.
Apparatus and method for non-invasive diagnosis and control of motor operated valve condition
Lyon, Richard H.; Chai, Jangbom; Lang, Jeffrey H.; Hagman, Wayne H.; Umans, Stephen D.; Saarela, Olli J.
1997-01-01
An apparatus compares the torque from an MOV motor with the valve displacement, and from the comparison assesses MOV operating condition. A transducer measures the vibration of the housing of an MOV. The vibrations are due to the motions of the rotating elements within the housing, which motions are directly related to the motion of the valve relative to its seat. Signal processing apparatus analyzes the vibrations to recover the rotations of the rotating elements and thus the motion of the valve plug. Lost motion can also be determined (if a lost motion connection exists) by demodulating the vibration signal and thus taking into account also the lost motion. Simultaneously, the forces applied to the valve are estimated by estimating the torque between the stator and the rotor of the motor. Such torque can be estimated from measuring the input current and voltage alone, using a forgetting factor and a correction for the forgetting factor. A signature derived from relating the torque to the valve position can be used to assess the condition of the MOV, by comparing the signature to signatures for MOVs of known conditions. The vibration analysis components generate signals that relate to the position of elements in the operator. Similarly, the torque estimator estimates the torque output by any type of electric motor, whether or not part of an MOV analysis unit.
Kang, Jung Youb; Nam, Ki Yup; Lee, Sang Joon; Lee, Seung Uk
2014-08-01
To evaluate the effect of intravitreal bevacizumab (IVB) before Ahmed valve implantation for treatment of neovascular glaucoma (NVG). This study is a retrospective, comparative, consecutive case series. The study group consisted of 27 eyes of 26 patients with NVG who underwent an Ahmed valve implantation. Thirteen eyes were treated with Ahmed valve implantation alone (control group), and 14 eyes were treated with a combination of preoperative IVB injection and Ahmed valve implantation (IVB group). Visual acuity, intraocular pressure (IOP), number of anti-glaucoma medications, surgical complications, and success rate were compared between the two groups. There were no significant differences in preoperative characteristics between the two groups. Visual acuity at 1, 2 weeks, and 1 month after surgery were significantly better in the IVB group (p = 0.038, 0.034, and 0.032, respectively). Hyphema associated with Ahmed valve implantation occurred significantly less in the IVB group (p = 0.016). On the other hand, the mean IOP and number of anti-glaucoma medications at all follow-up periods were similar between the two groups. Kaplan-Meier survival analysis showed the probability of success 6 months after surgery as 71.4 % in the IVB group and 84.6 % in the control group. No significant difference in success rate was found between the groups (p = 0.422). IVB before Ahmed valve implantation for treatment of NVG reduced the incidence of hyphema. In this retrospective study, IVB provided better visual outcome in the early postoperative periods but did not significantly improve mean IOP, number of anti-glaucoma medications, or success rate.
Nasal valve evaluation in the Mexican-Hispanic (mestizo) nose.
Jasso-Ramírez, Elizabeth; Sánchez Y Béjar, Fernando; Arcaute Aizpuru, Fernando; Maulen Radován, Irene E; de la Garza Hesles, Héctor
2018-04-01
Our aim in this study was to determine the angle of the internal nasal valve in Mexican patients with the "mestizo nose" feature and without nasal obstructive symptoms. The work was prospective, comparative, and observational in nature and included patients >14 years of age who were seen in the Otolaryngology Department at the Los Angeles Lomas Hospital between April and May 2016. The angle of the internal nasal valve was measured in 30 patients without obstructive symptoms. Endoscopic examination was performed with a 0° endoscope framed with tape at a 13-mm distance from the endoscope's tip, and digital photographs of the internal nasal valve were taken. The measurement of the angle of the internal nasal valve was made in sexagesimal degrees using Golden Ratio v3.1 (2012) software. Statistical analysis was performed using Excel v15.13.3. The angles of the internal nasal valve of the patients were (mean ± standard deviation) 24.07 ± 4.8° for the right nasal cavity and 25.07 ± 5.0° for the left nasal cavity, wider than the angle reported in the normal Caucasian nose established in the literature. According to our results, the Mexican-Hispanic mestizo nose has a wider angle in the internal nasal valve than that considered normal in the literature (10°-15°). We believe it is necessary to undertake a second study and add an airflow resistance measurement with a rhinomanometry procedure so we can compare the results with those in the Caucasian population. © 2018 ARS-AAOA, LLC.
Farag, Mina; Arif, Rawa; Sabashnikov, Anton; Zeriouh, Mohamed; Popov, Aron-Frederik; Ruhparwar, Arjang; Schmack, Bastian; Dohmen, Pascal M.; Szabó, Gábor; Karck, Matthias; Weymann, Alexander
2017-01-01
Background Long-term follow-up data concerning isolated tricuspid valve pathology after replacement or reconstruction is limited. Current American Heart Association guidelines equally recommend repair and replacement when surgical intervention is indicated. Our aim was to investigate and compare operative mortality and long-term survival in patients undergoing isolated tricuspid valve repair surgery versus replacement. Material/Methods Between 1995 and 2011, 109 consecutive patients underwent surgical correction of tricuspid valve pathology at our institution for varying structural pathologies. A total of 41 (37.6%) patients underwent tricuspid annuloplasty/repair (TAP) with or without ring implantation, while 68 (62.3%) patients received tricuspid valve replacement (TVR) of whom 36 (53%) were mechanical and 32 (47%) were biological prostheses. Results Early survival at 30 days after surgery was 97.6% in the TAP group and 91.1% in the TVR group. After 6 months, 89.1% in the TAP group and 87.8% in the TVR group were alive. In terms of long-term survival, there was no further mortality observed after one year post surgery in both groups (Log Rank p=0.919, Breslow p=0.834, Tarone-Ware p=0.880) in the Kaplan-Meier Survival analysis. The 1-, 5-, and 8-year survival rates were 85.8% for TAP and 87.8% for TVR group. Conclusions Surgical repair of the tricuspid valve does not show survival benefit when compared to replacement. Hence valve replacement should be considered generously in patients with reasonable suspicion that regurgitation after repair will reoccur. PMID:28236633
Mao, Wenbin; Li, Kewei; Sun, Wei
2016-01-01
Computational modeling of heart valve dynamics incorporating both fluid dynamics and valve structural responses has been challenging. In this study, we developed a novel fully-coupled fluid-structure interaction (FSI) model using smoothed particle hydrodynamics (SPH). A previously developed nonlinear finite element (FE) model of transcatheter aortic valves (TAV) was utilized to couple with SPH to simulate valve leaflet dynamics throughout the entire cardiac cycle. Comparative simulations were performed to investigate the impact of using FE-only models versus FSI models, as well as an isotropic versus an anisotropic leaflet material model in TAV simulations. From the results, substantial differences in leaflet kinematics between FE-only and FSI models were observed, and the FSI model could capture the realistic leaflet dynamic deformation due to its more accurate spatial and temporal loading conditions imposed on the leaflets. The stress and the strain distributions were similar between the FE and FSI simulations. However, the peak stresses were different due to the water hammer effect induced by the flow inertia in the FSI model during the closing phase, which led to 13%–28% lower peak stresses in the FE-only model compared to that of the FSI model. The simulation results also indicated that tissue anisotropy had a minor impact on hemodynamics of the valve. However, a lower tissue stiffness in the radial direction of the leaflets could reduce the leaflet peak stress caused by the water hammer effect. It is hoped that the developed FSI models can serve as an effective tool to better assess valve dynamics and optimize next generation TAV designs. PMID:27844463
Mao, Wenbin; Li, Kewei; Sun, Wei
2016-12-01
Computational modeling of heart valve dynamics incorporating both fluid dynamics and valve structural responses has been challenging. In this study, we developed a novel fully-coupled fluid-structure interaction (FSI) model using smoothed particle hydrodynamics (SPH). A previously developed nonlinear finite element (FE) model of transcatheter aortic valves (TAV) was utilized to couple with SPH to simulate valve leaflet dynamics throughout the entire cardiac cycle. Comparative simulations were performed to investigate the impact of using FE-only models vs. FSI models, as well as an isotropic vs. an anisotropic leaflet material model in TAV simulations. From the results, substantial differences in leaflet kinematics between FE-only and FSI models were observed, and the FSI model could capture the realistic leaflet dynamic deformation due to its more accurate spatial and temporal loading conditions imposed on the leaflets. The stress and the strain distributions were similar between the FE and FSI simulations. However, the peak stresses were different due to the water hammer effect induced by the fluid inertia in the FSI model during the closing phase, which led to 13-28% lower peak stresses in the FE-only model compared to that of the FSI model. The simulation results also indicated that tissue anisotropy had a minor impact on hemodynamics of the valve. However, a lower tissue stiffness in the radial direction of the leaflets could reduce the leaflet peak stress caused by the water hammer effect. It is hoped that the developed FSI models can serve as an effective tool to better assess valve dynamics and optimize next generation TAV designs.
Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients.
Reardon, Michael J; Van Mieghem, Nicolas M; Popma, Jeffrey J; Kleiman, Neal S; Søndergaard, Lars; Mumtaz, Mubashir; Adams, David H; Deeb, G Michael; Maini, Brijeshwar; Gada, Hemal; Chetcuti, Stanley; Gleason, Thomas; Heiser, John; Lange, Rüdiger; Merhi, William; Oh, Jae K; Olsen, Peter S; Piazza, Nicolo; Williams, Mathew; Windecker, Stephan; Yakubov, Steven J; Grube, Eberhard; Makkar, Raj; Lee, Joon S; Conte, John; Vang, Eric; Nguyen, Hang; Chang, Yanping; Mugglin, Andrew S; Serruys, Patrick W J C; Kappetein, Arie P
2017-04-06
Although transcatheter aortic-valve replacement (TAVR) is an accepted alternative to surgery in patients with severe aortic stenosis who are at high surgical risk, less is known about comparative outcomes among patients with aortic stenosis who are at intermediate surgical risk. We evaluated the clinical outcomes in intermediate-risk patients with severe, symptomatic aortic stenosis in a randomized trial comparing TAVR (performed with the use of a self-expanding prosthesis) with surgical aortic-valve replacement. The primary end point was a composite of death from any cause or disabling stroke at 24 months in patients undergoing attempted aortic-valve replacement. We used Bayesian analytical methods (with a margin of 0.07) to evaluate the noninferiority of TAVR as compared with surgical valve replacement. A total of 1746 patients underwent randomization at 87 centers. Of these patients, 1660 underwent an attempted TAVR or surgical procedure. The mean (±SD) age of the patients was 79.8±6.2 years, and all were at intermediate risk for surgery (Society of Thoracic Surgeons Predicted Risk of Mortality, 4.5±1.6%). At 24 months, the estimated incidence of the primary end point was 12.6% in the TAVR group and 14.0% in the surgery group (95% credible interval [Bayesian analysis] for difference, -5.2 to 2.3%; posterior probability of noninferiority, >0.999). Surgery was associated with higher rates of acute kidney injury, atrial fibrillation, and transfusion requirements, whereas TAVR had higher rates of residual aortic regurgitation and need for pacemaker implantation. TAVR resulted in lower mean gradients and larger aortic-valve areas than surgery. Structural valve deterioration at 24 months did not occur in either group. TAVR was a noninferior alternative to surgery in patients with severe aortic stenosis at intermediate surgical risk, with a different pattern of adverse events associated with each procedure. (Funded by Medtronic; SURTAVI ClinicalTrials.gov number, NCT01586910 .).
Gosev, Igor; Yammine, Maroun; McGurk, Siobhan; Ejiofor, Julius I; Norman, Anthony; Ivkovic, Vladimir; Cohn, Lawrence H
The risks vs benefits of tricuspid valve (TV) surgery in reoperative patients requiring left-sided valve surgery and moderate-to-severe tricuspid regurgitation is unclear. We compared patients with and without concomitant TV surgery. A total of 200 patients with moderate-to-severe TV regurgitation had reoperative left-sided valve procedures from January 2002 to April 2014; 75 with TV intervention (TVI) and 125 with no tricuspid intervention (TVN). Propensity-matched cohorts of 60 TVI and 60 TVN patients were compared. Outcomes included New York Heart Association class, TV regurgitation and survival. TVI patients were younger (66 ± 15 vs 72 ± 13 years, P < 0.001), had more cardiogenic shock (6 of 75, vs 0 of 125, P < 0.001) and mitral valve surgery (60 of 75 vs 69 of 125, P < 0.001). Propensity matching yielded 60 pairs of TVI cases and TVN controls. Matched groups were comparable in age (TVI = 67 ± 13 vs TVN 68 ± 14 years, P = 0.67), cardiogenic shock (2 vs 0, P = 0.50), and mitral valve surgery (15 each, P = 1.0). Operative mortality was 2 of 60 in TVI vs 10 of 60 TVN (P = 0.27). Median follow-up was 4.4 years. Follow-up rates of New York Heart Association class III-IV were similar (12 of 60 for TVI vs 16 of 60 TVN, P = 0.52). Kaplan-Meier analysis indicated improved event-free survival for TVI patients (6 years, 95% CI: 4.8-7.2 years vs 8 years, 95% CI: 6.7-9.3 years for TVN, P = 0.030). There was a trend towards increased TR at follow-up in patients with valve repair alone vs annuloplasty (P = 0.15). TV surgery was performed more often in higher-risk patients. Matched case-control analyses showed TVI was associated with improved midterm outcomes. Our data suggest that annuloplasty was preferable to TV repair alone. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Yu, Y. H.; Liu, D.; Yang, X. F.; Si, J.
2017-08-01
To analyse the flow characteristics of leakage as well as the mechanism of selfexcited vibration in valves, the method of characteristics was used to assess the effect of flexible valve leakage on the self-excited vibration in water-supply pump system. Piezometric head in upstream of the valve as a function of time was obtained. Two comparative schemes were proposed to simulate the process of self-excited vibration by changing the length, the material of the pipeline and the leakage of valves in the above pump system. It is shown that the length and material of the pipe significantly affect the amplitude and cycle of self-excited vibration as well as the increasing rate of the vibration amplitude. In addition, the leakage of the valve has little influence on the amplitude and cycle of self-excited vibration, but has a significant effect on the increasing rate of vibration amplitude. A pipe explosion accident may occur without the inhibiting of self-excited vibration.
Thavendiranathan, Paaladinesh; Verhaert, David; Walls, Michael C.; Bender, Jacob A.; Rajagopalan, Sanjay; Chung, Yiu-Cho; Simonetti, Orlando P.; Raman, Subha V.
2015-01-01
OBJECTIVES The purpose of this study was to evaluate the ability of a novel cardiac magnetic resonance (CMR) real-time phase contrast (RT-PC) flow measurement technique to reveal the discordant respirophasic changes in mitral and tricuspid valve in flow indicative of the abnormal hemodynamics seen in constrictive pericarditis (CP). BACKGROUND Definitive diagnosis of CP requires identification of constrictive hemodynamics with or without pericardial thickening. CMR to date has primarily provided morphological assessment of the pericardium. METHODS Sixteen patients (age 57 ± 13 years) undergoing CMR to assess known or suspected CP and 10 controls underwent RT-PC that acquired simultaneous mitral valve and tricuspid valve inflow velocities over 10 s of unrestricted breathing. The diagnosis of CP was confirmed via clinical history, diagnostic imaging, cardiac catheterization, intraoperative findings, and histopathology. RESULTS Ten patients had CP, all with increased pericardial thickness (6.2 ± 1.0 mm). RT-PC imaging demonstrated discordant respirophasic changes in atrioventricular valve inflow velocities in all CP patients, with mean ± SD mitral valve and tricuspid valve inflow velocity variation of 46 ± 20% and 60 ± 15%, respectively, compared with 16 ± 8% and 24 ± 11% in patients without CP (p < 0.004 vs. patients with CP for both) and 17 ± 5% and 31 ± 13% in controls (p < 0.001 vs. patients with CP for both). There was no difference in atrioventricular valve inflow velocity variation between patients without CP compared with controls (p > 0.3 for both). Respiratory variation exceeding 25% across the mitral valve yielded a sensitivity of 100%, a specificity of 100%, and an area under the receiver-operating characteristic curve of 1.0 to detect CP physiology. Using a cutoff of 45%, variation of transtricuspid valve velocity had a sensitivity of 90%, a specificity of 88%, and an area under the receiver-operating characteristic curve of 0.98. CONCLUSIONS Accentuated and discordant respirophasic changes in mitral valve and tricuspid valve inflow velocities characteristic of CP can be identified noninvasively with RT-PC CMR. When incorporated into existing CMR protocols for imaging pericardial morphology, RT-PC CMR provides important hemodynamic evidence with which to make a definite diagnosis of CP. PMID:22239888
Collagen organization in canine myxomatous mitral valve disease: an x-ray diffraction study.
Hadian, Mojtaba; Corcoran, Brendan M; Han, Richard I; Grossmann, J Günter; Bradshaw, Jeremy P
2007-10-01
Collagen fibrils, a major component of mitral valve leaflets, play an important role in defining shape and providing mechanical strength and flexibility. Histopathological studies show that collagen fibrils undergo dramatic changes in the course of myxomatous mitral valve disease in both dogs and humans. However, little is known about the detailed organization of collagen in this disease. This study was designed to analyze and compare collagen fibril organization in healthy and lesional areas of myxomatous mitral valves of dogs, using synchrotron small-angle x-ray diffraction. The orientation, density, and alignment of collagen fibrils were mapped across six different valves. The findings reveal a preferred collagen alignment in the main body of the leaflets between two commissures. Qualitative and quantitative analysis of the data showed significant differences between affected and lesion-free areas in terms of collagen content, fibril alignment, and total tissue volume. Regression analysis of the amount of collagen compared to the total tissue content at each point revealed a significant relationship between these two parameters in lesion-free but not in affected areas. This is the first time this technique has been used to map collagen fibrils in cardiac tissue; the findings have important applications to human cardiology.
NASA Astrophysics Data System (ADS)
Ventura, J.; Sousa, J. B.; Veloso, A.; Freitas, P. P.
2007-05-01
Specular spin valves show enhanced giant magnetoresistive ratio when compared to other simpler, spin valve structures as a result of specular reflection in nano-oxide layers (NOLs) formed by the partial oxidation of the CoFe pinned and free layers. The oxides forming the NOL were recently shown to order antiferromagnetically below T ˜175K. Here we study the training effect in MnIr /CoFe/NOL/CoFe/Cu/CoFe/NOL specular spin valves at low temperatures (15K). We observed that the training effect is related to the nano-oxide layer antiferromagnet ordering and to the evolution of the corresponding domain structure with the number of cycles performed. This allowed us to study the influence of the NOL domain structure on the magnetotransport of specular spin valves.
Engine control system having pressure-based timing
Willi, Martin L [Dunlap, IL; Fiveland, Scott B [Metamora, IL; Montgomery, David T [Edelstein, IL; Gong, Weidong [Dunlap, IL
2011-10-04
A control system for an engine having a first cylinder and a second cylinder is disclosed having a first engine valve movable to regulate a fluid flow of the first cylinder and a first actuator associated with the first engine valve. The control system also has a second engine valve movable to regulate a fluid flow of the second cylinder and a sensor configured to generate a signal indicative of a pressure within the first cylinder. The control system also has a controller that is in communication with the first actuator and the sensor. The controller is configured to compare the pressure within the first cylinder with a desired pressure and selectively regulate the first actuator to adjust a timing of the first engine valve independently of the timing of the second engine valve based on the comparison.
Pros and cons of transcatheter aortic valve implantation (TAVI).
Terré, Juan A; George, Isaac; Smith, Craig R
2017-09-01
Transcatheter aortic valve implantation (TAVI) or replacement (TAVR) was recently approved by the FDA for intermediate risk patients with severe aortic stenosis (AS). This technique was already worldwide adopted for inoperable and high-risk patients. Improved device technology, imaging analysis and operator expertise has reduced the initial worrisome higher complications rate associated with TAVR, making it comparable to surgical aortic valve replacement (SAVR). However, many answers need to be addressed before adoption in lower risk patients. This paper highlights the pros and cons of TAVI based mostly on randomized clinical trials involving the two device platforms approved in the United States. We focused our analysis on metrics that will play a key role in expanding TAVR indication in healthier individuals. We review the significance and gave a perspective on paravalvular leak (PVL), valve performance, valve durability, leaflet thrombosis, stroke and pacemaker requirement.
NASA Astrophysics Data System (ADS)
Abbas, S. S.; Nasif, M. S.; Said, M. A. M.; Kadhim, S. K.
2017-10-01
Structural stresses developed in an artificial bileaflet mechanical heart valve (BMHV) due to pulsed blood flow may cause valve failure due to yielding. In this paper, von-Mises stresses are computed and compared for BMHV placed in two types of aortic root geometries that are aortic root with axisymmetric sinuses and with axisymmetric bulb, at different physiological blood flow rates. With BMHV placed in an aortic root with axisymmetric sinuses, the von-Mises stresses developed in the valve were found to be up to 47% higher than BMHV placed in aortic root with axisymmetric bulb under similar physiological conditions. High velocity vectors and therefore high von-Mises stresses have been observed for BMHV placed in aortic root with axisymmetric sinuses, that can lead to valve failure.
TAVR vs SAVR: Rising Expectations and Changing Indications for Surgery in Response to PARTNER II.
Spadaccio, Cristiano; Nappi, Francesco; Sablayrolles, Jean-Louis; Sutherland, Fraser W H
2017-01-01
Despite the criticisms and concerns raised on the data published in the PARTNER II trial and related analyses, we are undeniably witnessing a revolution in the management of aortic valve disease, in which conventional full sternotomy surgical aortic valve replacement (SAVR), with all related complications and clinical burden, will soon become a nonviable option. Several of the findings described in the PARTNER II trial, although considerable as points of incongruence and study biases in comparison with SAVR, could be taken as lessons to found a new course in SAVR and redesign the respective roles of surgery and interventional procedures in aortic disease. In particular, the results of these trials can actually be considered as a stimulus to invest more effort to improve the current surgical practice that should embrace alternative solutions and least invasive approaches to provide a competitive advantage over percutaneous procedures. An analysis of these points in light of the more recent findings on transcatheter valve durability, thrombosis, and postprocedural complications is provided. Considerations on the parallel progress of SAVR and on the need for a behavioral change in the surgical community are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.
Tissier, R; Chetboul, V; Moraillon, R; Nicolle, A; Carlos, C; Enriquez, B; Pouchelon, J-L
2005-01-01
The aim of this article is to describe original adverse effects in two dogs chronically treated with the inodilator pimobendan. We report a German shepherd (i.e., dog 1) and a poodle (i.e., dog 2) that were referred to our cardiology unit after receiving pimobendan for 10 and 5 mo, respectively. In both dogs, conventional echo-Doppler examination demonstrated mitral valve regurgitation and myocardial hypertrophy. Tissue Doppler imaging (TDI) was performed in the first case and revealed an abnormal relaxation phase. After the first examination, pimobendan administration was stopped in both cases and dogs were re-examined 3 and 1 mo later, respectively. Mitral valve regurgitation assessed by echocardiography decreased in both dogs, and the systolic heart murmur disappeared in dog 1. Importantly, most echocardiographic and TDI parameters tended to normalize in dog 1, suggesting, at least partial reversal of both myocardial hypertrophy and relaxation abnormality produced during inodilator therapy. This is the first report to describe an increase in mitral regurgitation under clinical conditions in dogs treated with pimobendan. We also suggest that pimobendan may induce ventricular hypertrophy. However, prospective studies are needed to confirm this observation.
High Frequency of Tropheryma whipplei in Culture-Negative Endocarditis
Geißdörfer, Walter; Moter, Annette; Loddenkemper, Christoph; Jansen, Andreas; Tandler, René; Morguet, Andreas J.; Fenollar, Florence; Raoult, Didier; Bogdan, Christian
2012-01-01
“Classical” Whipple's disease (cWD) is caused by Tropheryma whipplei and is characterized by arthropathy, weight loss, and diarrhea. T. whipplei infectious endocarditis (TWIE) is rarely reported, either in the context of cWD or as isolated TWIE without signs of systemic infection. The frequency of TWIE is unknown, and systematic studies are lacking. Here, we performed an observational cohort study on the incidence of T. whipplei infection in explanted heart valves in two German university centers. Cardiac valves from 1,135 patients were analyzed for bacterial infection using conventional culture techniques, PCR amplification of the bacterial 16S rRNA gene, and subsequent sequencing. T. whipplei-positive heart valves were confirmed by specific PCR, fluorescence in situ hybridization, immunohistochemistry, histological examination, and culture for T. whipplei. Bacterial endocarditis was diagnosed in 255 patients, with streptococci, staphylococci, and enterococci being the main pathogens. T. whipplei was the fourth most frequent pathogen, found in 16 (6.3%) cases, and clearly outnumbered Bartonella quintana, Coxiella burnetii, and members of the HACEK group (Haemophilus species, Actinobacillus actinomycetemcomitans, Cardiobacterium hominis, Eikenella corrodens, and Kingella kingae). In this cohort, T. whipplei was the most commonly found pathogen associated with culture-negative infective endocarditis. PMID:22135251
Application of Hydrodynamic Cavitation for Food and Bioprocessing
NASA Astrophysics Data System (ADS)
Gogate, Parag R.
Hydrodynamic cavitation can be simply generated by the alterations in the flow field in high speed/high pressure devices and also by passage of the liquid through a constriction such as orifice plate, venturi, or throttling valve. Hydrodynamic cavitation results in the formation of local hot spots, release of highly reactive free radicals, and enhanced mass transfer rates due to turbulence generated as a result of liquid circulation currents. These conditions can be suitably applied for intensification of different bioprocessing applications in an energy-efficient manner as compared to conventionally used ultrasound-based reactors. The current chapter aims at highlighting different aspects related to hydrodynamic cavitation, including the theoretical aspects for optimization of operating parameters, reactor designs, and overview of applications relevant to food and bioprocessing. Some case studies highlighting the comparison of hydrodynamic cavitation and acoustic cavitation reactors will also be discussed.
Cui, Qi N; Hsia, Yen C; Lin, Shan C; Stamper, Robert L; Rose-Nussbaumer, Jennifer; Mehta, Nitisha; Porco, Travis C; Naseri, Ayman; Han, Ying
2017-03-01
To examine the effect of mitomycin c and 5-flurouracil on treatment outcomes following Ahmed glaucoma valve implantation. Retrospective consecutive case series. Fifty patients who received Ahmed glaucoma valve implantation from 1999 to 2013 in the San Francisco Veterans Administration Hospital. The +INJECTION group received intraoperative mitomycin c followed by postoperative mitomycin c and/or 5-flurouracil, whereas the -INJECTION group did not. Primary outcome was treatment success at 1 year post-implantation. Intraocular pressure, hypertensive phase, and the number of glaucoma medications were also examined. Twenty-six patients/eyes in the +INJECTION group and 24 patients/eyes in the -INJECTION group were included. Treatment success was higher in the +INJECTION compared with the -INJECTION group (86 vs. 58%; P = 0.04). Intraocular pressure was lower in the +INJECTION compared with the -INJECTION group at 1, 3, 6 and 12 months (P ≪ 0.00001, P = 0.00003, 0.0008 and 0.024). Hypertensive phase occurred less often in the +INJECTION compared with the -INJECTION group (3.8 vs. 54%; P = 0.021). The +INJECTION group required fewer medications compared with the -INJECTION group (P = 0.02, 0.002, 0.003 and 0.008 at 1, 3, 6 and 12 months). Complication rates were comparable between groups (46.2 and 54.2%; P = 0.63). Adjuvant treatment with antifibrotics following Ahmed glaucoma valve implantation decreased the hypertensive phase and improved surgical outcomes without impacting complication rates at 1 year. This study postulates a role for antifibrotics in the postoperative management of Ahmed glaucoma valves. © 2016 Royal Australian and New Zealand College of Ophthalmologists.
Coronary flow characteristics after a Bentall procedure with or without sinuses of Valsalva.
de Paulis, Ruggero; Tomai, Fabrizio; Bertoldo, Fabio; Ghini, Anna S; Scaffa, Raffaele; Nardi, Paolo; Chiariello, Luigi
2004-07-01
The sinuses of Valsalva are known to contribute to the normal function of the aortic valve. Little is known about their role in promoting coronary artery blood flow. The aim of this study was to compare coronary artery flow characteristics among patients undergoing a Bentall operation by means of a conventional cylindrical Dacron conduit or with a new conduit with pseudosinuses of Valsalva or in patients retaining their natural sinuses of Valsalva after aortic valve and supracoronary ascending aorta replacement. One year after a Bentall procedure with a standard cylindrical Dacron conduit (7 patients, group A) or with the new conduit (7 patients, group B), or after aortic valve and ascending aortic replacement (control group, 7 patients, group C) coronary flow velocity reserve and diastolic to systolic time integral ratio at baseline and after maximal hyperemia (with 40 microg of adenosine) were assessed by using a 0.014-in. Doppler guidewire positioned in the middle portion of the left anterior descending coronary artery. All patients were in NYHA class I, sinus rhythm and free of coronary disease. Arterial blood pressures and heart rate were comparable among groups. Intracoronary Doppler measurements did not show any significant difference in coronary vascular reserve between the three groups (3.6+/-0.4 vs 3.1+/-0.7 vs 3.7+/-0.5, P = 0.2). A greater diastolic component at baseline was present in group B patients (5.5+/-1.9 vs 3.5+/-0.9 in group A and 3.7+/-0.9 in group C, P = 0.024). After maximal hyperemia the diastolic component increased slightly in group A patients (8%) while both in groups B and C significantly decreased (-15 and -20%, respectively) (P = 0.017). The presence of pseudosinuses of Valsalva does not influence coronary flow reserve. After maximal coronary vasodilation the increase in the systolic component of coronary flow is more evident in the presence of sinuses or pseudosinuses of Valsalva, thus suggesting that coronary flow pattern may be affected by the presence of sinuses.
Determination of oxidation state of iron in normal and pathologically altered human aortic valves
NASA Astrophysics Data System (ADS)
Czapla-Masztafiak, J.; Lis, G. J.; Gajda, M.; Jasek, E.; Czubek, U.; Bolechała, F.; Borca, C.; Kwiatek, W. M.
2015-12-01
In order to investigate changes in chemical state of iron in normal and pathologically altered human aortic valves X-ray absorption spectroscopy was applied. Since Fe is suspected to play detrimental role in aortic valve stenosis pathogenesis the oxidation state of this element has been determined. The experimental material consisted of 10 μm sections of valves excised during routine surgery and from autopsies. The experiment was performed at the MicroXAS beamline of the SLS synchrotron facility in Villigen (Switzerland). The Fe K-edge XANES spectra obtained from tissue samples were carefully analyzed and compared with the spectra of reference compounds containing iron in various chemical structures. The analysis of absorption edge position and shape of the spectra revealed that both chemical forms of iron are presented in valve tissue but Fe3+ is the predominant form. Small shift of the absorption edge toward higher energy in the spectra from stenotic valve samples indicates higher content of the Fe3+ form in pathological tissue. Such a phenomenon suggests the role of Fenton reaction and reactive oxygen species in the etiology of aortic valve stenosis. The comparison of pre-edge regions of XANES spectra for control and stenotic valve tissue confirmed no differences in local symmetry or spin state of iron in analyzed samples.
Carrion, Katrina; Dyo, Jeffrey; Patel, Vishal; Sasik, Roman; Mohamed, Salah A; Hardiman, Gary; Nigam, Vishal
2014-01-01
Aortic valve calcification is a significant and serious clinical problem for which there are no effective medical treatments. Individuals born with bicuspid aortic valves, 1-2% of the population, are at the highest risk of developing aortic valve calcification. Aortic valve calcification involves increased expression of calcification and inflammatory genes. Bicuspid aortic valve leaflets experience increased biomechanical strain as compared to normal tricuspid aortic valves. The molecular pathogenesis involved in the calcification of BAVs are not well understood, especially the molecular response to mechanical stretch. HOTAIR is a long non-coding RNA (lncRNA) that has been implicated with cancer but has not been studied in cardiac disease. We have found that HOTAIR levels are decreased in BAVs and in human aortic interstitial cells (AVICs) exposed to cyclic stretch. Reducing HOTAIR levels via siRNA in AVICs results in increased expression of calcification genes. Our data suggest that β-catenin is a stretch responsive signaling pathway that represses HOTAIR. This is the first report demonstrating that HOTAIR is mechanoresponsive and repressed by WNT β-catenin signaling. These findings provide novel evidence that HOTAIR is involved in aortic valve calcification.
Gas absorption/desorption temperature-differential engine
NASA Technical Reports Server (NTRS)
Miller, C. G.
1981-01-01
Continuously operating compressor system converts 90 percent of gas-turbine plant energy to electricity. Conventional plants work in batch mode, operating at 40 percent efficiency. Compressor uses metal hydride matrix on outside of rotating drum to generate working gas, hydrogen. Rolling valve seals allow continuous work. During operation, gas is absorbed, releasing heat, and desorbed with heat gain. System conserves nuclear and fossil fuels, reducing powerplant capital and operating costs.
Echocardiography in mitral stenosis
Omran, A.S.; Arifi, Ahmed A.; Mohamed, A.A.
2010-01-01
Echocardiography plays a major role in diagnosis, etiology and severity of Mitral Stenosis (MS), analysis of valve anatomy and decision-making for intervention. This technique has also a crucial role to assess consequences of MS and follow up of patients after medical or surgical intervention. In this article we review the role of conventional echocardiography in assessment of mitral stenosis and future direction of this modality using 3D echocardiography. PMID:23960637
NASA Astrophysics Data System (ADS)
Gurram, M.; Omar, S.; van Wees, B. J.
2018-07-01
The current research in graphene spintronics strives for achieving a long spin lifetime, and efficient spin injection and detection in graphene. In this article, we review how hexagonal boron nitride (hBN) has evolved as a crucial substrate, as an encapsulation layer, and as a tunnel barrier for manipulation and control of spin lifetimes and spin injection/detection polarizations in graphene spin valve devices. First, we give an overview of the challenges due to conventional SiO2/Si substrate for spin transport in graphene followed by the progress made in hBN based graphene heterostructures. Then we discuss in detail the shortcomings and developments in using conventional oxide tunnel barriers for spin injection into graphene followed by introducing the recent advancements in using the crystalline single/bi/tri-layer hBN tunnel barriers for an improved spin injection and detection which also can facilitate two-terminal spin valve and Hanle measurements at room temperature, and are of technological importance. A special case of bias induced spin polarization of contacts with exfoliated and chemical vapour deposition (CVD) grown hBN tunnel barriers is also discussed. Further, we give our perspectives on utilizing graphene-hBN heterostructures for future developments in graphene spintronics.
Ouweneel, Dagmar M; Sjauw, Krischan D; Wiegerinck, Esther M A; Hirsch, Alexander; Baan, Jan; de Mol, Bas A J M; Lagrand, Wim K; Planken, R Nils; Henriques, José P S
2016-10-01
The use of intracardiac assist devices is expanding, and correct position of these devices is required for optimal functioning. The aortic valve is an important landmark for positioning of those devices. It would be of great value if the device position could be easily monitored on plain supine chest radiograph in the ICU. We introduce a ratio-based tool for determination of the aortic valve location on plain supine chest radiograph images, which can be used to evaluate intracardiac device position. Retrospective observational study. Large academic medical center. Patients admitted to the ICU and supported by an intracardiac assist device. We developed a ratio to determine the aortic valve location on supine chest radiograph images. This ratio is used to assess the position of a cardiac assist device and is compared with echocardiographic findings. Supine anterior-posterior chest radiographs of patients with an aortic valve prosthesis (n = 473) were analyzed to determine the location of the aortic valve. We calculated several ratios with the potential to determine the position of the aortic valve. The aortic valve location ratio, defined as the distance between the carina and the aortic valve, divided by the thoracic width, was found to be the best performing ratio. The aortic valve location ratio determines the location of the aortic valve caudal to the carina, at a distance of 0.25 ± 0.05 times the thoracic width for male patients and 0.28 ± 0.05 times the thoracic width for female patients. The aortic valve location ratio was validated using CT images of patients with angina pectoris without known valvular disease (n = 95). There was a good correlation between cardiac device position (Impella) assessed with the aortic valve location ratio and with echocardiography (n = 53). The aortic valve location ratio enables accurate and reproducible localization of the aortic valve on supine chest radiograph. This tool is easily applicable and can be used for assessment of cardiac device position in patients on the ICU.
The importance of echocardiography in transcatheter aortic valve implantation.
Bilen, Emine; Sari, Cenk; Durmaz, Tahir; Keleş, Telat; Bayram, Nihal A; Akçay, Murat; Ayhan, Hüseyin M; Bozkurt, Engin
2014-01-01
Valvular heart diseases cause serious health problems in Turkey as well as in Western countries. According to a study conducted in Turkey, aortic stenosis (AS) is second after mitral valve disease among all valvular heart diseases. AS is frequently observed in elderly patients who have several cardiovascular risk factors and comorbidities. In symptomatic severe AS, surgical aortic valve replacement (AVR) is a definitive treatment. However, in elderly patients with left ventricular dysfunction and comorbidities, the risk of operative morbidity and mortality increases and outweighs the gain obtained from AVR surgery. As a result, almost one-third of the patients with serious AS are considered ineligible for surgery. Transcatheter aortic valve implantation (TAVI) is an effective treatment in patients with symptomatic severe AS who have high risk for conventional surgery. Since being performed for the first time in 2002, with a procedure success rate reported as 95% and a mortality rate of 5%, TAVI has become a promising method. Assessment of vascular anatomy, aortic annular diameter, and left ventricular function may be useful for the appropriate selection of patients and may reduce the risk of complications. Cardiac imaging methods including 2D and 3D echocardiography and multidetector computed tomography are critical during the evaluation of suitable patients for TAVI as well as during and after the procedure. In this review, we describe the role of echocardiography methods in clinical practice for TAVI procedure in its entirety, i.e. from patient selection to guidance during the procedure, and subsequent monitoring. © 2013, Wiley Periodicals, Inc.
Lauten, Alexander; Laube, Adrian; Schubert, Harald; Bischoff, Sabine; Nietzsche, Sandor; Horstkötter, Kim; Poudel-Bochmann, Bhawana; Franz, Marcus; Lichtenberg, Artur; Figulla, Hans R; Akhyari, Payam
2015-01-01
Caval valve implantation has been suggested for transcatheter treatment of severe tricuspid regurgitation (TR). Combining the interventional technique with the promising surgical experience with decellularized valves, we sought to evaluate the functional and structural outcome of decellularized pericardial tissue valves (dTVs) in the low-pressure venous circulation in a chronic model of TR. Sixteen pericardial tissue valves were heterotopically implanted in the inferior and superior vena cava in a sheep model (54-98 kg; median 74.5 kg, n = 8) of severe TR. The devices were assembled using self-expanding nitinol stents and bovine pericardia decellularized by a detergent-based protocol (group dTV; n = 8). Glutaraldehyde-fixed pericardial tissue valves served as control (GaTV, n = 8). After 6 months, device function and structural maturation were analyzed using echocardiographic, histologic, immunohistologic, and electron microscopic approaches. After implantation, cardiac output increased significantly from 3.7 ± 1.1 l/min to 4.8 ± 1.1 l/min (P < 0.05) and competent valve function was verified by angiography. At 6 months, angiographic and echocardiographic evaluation revealed moderate to severe regurgitation in all GaTV. In contrast, five of the eight dTVs functioned well with only minor regurgitation. In these animals, autopsy revealed preserved valve structure with tender leaflets without signs of thrombosis or calcification. Conversely, GaTV showed severe degeneration with large calcification areas. Microscopic and histologic analysis confirmed endothelial repopulation in both valve types. However, additional interstitial reseeding was observed in decellularized valves. In the venous circulation in severe TR, decellularized valves show superior functional performance compared to Ga-fixed tissue valves. Macroscopic and microscopic analyses suggest preserved structural integrity and advanced endothelial and interstitial repopulation with evidence of less degradation in dTV. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.
Characterization of small microfluidic valves for studies of mechanical properties of bacteria
Yang, Da; Greer, Clayton M.; Jones, Branndon P.; ...
2015-09-02
Lab-on-a-chip platforms present many new opportunities to study bacterial cells and cellular assemblies. Here, the authors describe a new platform that allows us to apply uniaxial stress to individual bacterial cells while observing the cell and its subcellular assemblies using a high resolution optical microscope. The microfluidic chip consists of arrays of miniature pressure actuated valves. By placing a bacterium under one of such valves and partially closing the valve by externally applied pressure, the cell can be deformed. Although large pressure actuated valves used in integrated fluidic circuits have been extensively studied previously, here the authors downsize those microfluidicmore » valves and use flow channels with rectangular cross-sections to maintain the bacteria in contact with cell culture medium during the experiments. The closure of these valves has not been characterized before. First, these valves are modeled using finite element analysis, and then compared the modeling results with the actual closing profiles of the valves, which is determined from absorption measurements. The measurements and modeling show with good agreement that the deflection of valves is a linear function of externally applied pressure and the deflection scales proportionally to the width of the flow channel. In addition to characterizing the valve, the authors show at a proof-of-principle level that it can be used to deform a bacterial cell at considerable magnitude. They found the largest deformations in 5 μm wide channels where the bacterial width and length increase by 1.6 and 1.25 times, respectively. Narrower and broader channels are less optimal for these studies. Finally, the platform presents a promising approach to probe, in a quantitative and systematic way, the mechanical properties of not only bacterial cells but possibly also yeast and other single-celled organisms.« less
Disentangling diatom species complexes: does morphometry suffice?
Borrego-Ramos, María; Olenici, Adriana
2017-01-01
Accurate taxonomic resolution in light microscopy analyses of microalgae is essential to achieve high quality, comparable results in both floristic analyses and biomonitoring studies. A number of closely related diatom taxa have been detected to date co-occurring within benthic diatom assemblages, sharing many morphological, morphometrical and ecological characteristics. In this contribution, we analysed the hypothesis that, where a large sample size (number of individuals) is available, common morphometrical parameters (valve length, width and stria density) are sufficient to achieve a correct identification to the species level. We focused on some common diatom taxa belonging to the genus Gomphonema. More than 400 valves and frustules were photographed in valve view and measured using Fiji software. Several statistical tools (mixture and discriminant analysis, k-means clustering, classification trees, etc.) were explored to test whether mere morphometry, independently of other valve features, leads to correct identifications, when compared to identifications made by experts. In view of the results obtained, morphometry-based determination in diatom taxonomy is discouraged. PMID:29250472
Baron Toaldo, M; Romito, G; Guglielmini, C; Diana, A; Pelle, N G; Contiero, B; Cipone, M
2017-05-01
The assessment of left atrial (LA) function by 2-dimensional speckle tracking echocardiography (STE) holds important clinical implications in human medicine. Few similar data are available in dogs. To assess LA function by STE in dogs with and without myxomatous mitral valve disease (MMVD), analyzing LA areas, systolic function, and strain. One hundred and fifty dogs were divided according to the American College of Veterinary Internal Medicine classification of heart failure: 23 dogs in class A, 52 in class B1, 36 in class B2, and 39 in class C + D. Prospective observational study. Conventional morphologic and Doppler variables, LA areas, and STE-based LA strain analysis were performed in all dogs and results were compared among groups. Correlation analysis was carried out between LA STE variables and other echocardiographic variables. Variability study showed good reproducibility for all the tested variables (coefficient of variation <16%). Left atrial areas, fractional area change, peak atrial longitudinal strain (PALS), peak atrial contraction strain, and contraction strain index (CSI) differed significantly between groups B2 and C + D and all the other groups (overall P < .001), whereas only PALS differed between groups B1 and A (P = .01). Left atrial areas increased with progression of the disease, whereas LA functional parameters decreased. Only CSI increased nonsignificantly from group A to group B1 and then progressively decreased. Thirty-one significant correlations (P < .001, r > .3) were found between conventional left heart echocardiographic variables and LA areas and strain variables. Left atrial STE analysis provides useful information on atrial function in the dog, highlighting a progressive decline in atrial function with worsening of MMVD. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Basel, Halil; Aydin, Unal; Kutlu, Hakan; Dostbil, Aysenur; Karadag, Melike; Odabasi, Dolunay; Aydin, Cemalettin
2010-08-01
The aim of this study was to compare De Vega semicircular annuloplasty and a new biodegradable ring annuloplasty technique in patients requiring surgical intervention for tricuspid valve disease with concomitant disease of the mitral valve. Between January 2004 and May 2008, 129 consecutive patients underwent annuloplasty procedures to correct tricuspid valve regurgitation during a concomitant mitral valve operation requiring replacement. Additionally, 24 patients underwent aortic valve replacement (AVR), 11 underwent coronary artery bypass grafting (CABG), 5 underwent AVR plus CABG, 3 underwent mitral valve replacement plus atrial septal defect (ASD) closure, and 2 underwent ASD closure. The patients in this study were assigned to 2 groups: Kalangos ring annuloplasty was performed in 67 patients (group 1), and De Vega semicircular annuloplasty was performed in the remaining 62 patients (group 2). Both tricuspid valve repair techniques produced a low rate of complications; however, the number of patients who developed residual tricuspid regurgitation was significantly lower in group 1. The biodegradable ring annuloplasty technique may be used easily and safely in moderate and severe cases of tricuspid regurgitation; however, larger clinical series are necessary to confirm our promising results.
Mechanics of cryopreserved aortic and pulmonary homografts.
Vesely, I; Casarotto, D C; Gerosa, G
2000-01-01
The surgical placement of pulmonary valve grafts into the aortic position (the Ross procedure) has been performed for three decades. Cryopreserved pulmonary valves have had mixed clinical results, however. The objectives of this study were to compare the mechanics of cryopreserved human aortic and pulmonary valve cusps and roots to determine if the pulmonary root can withstand the greater pressures of the aortic position. Six aortic and six pulmonary valve roots were obtained from the Oxford Valve Bank. They were harvested during cardiac transplantation from hearts explanted for dilated cardiomyopathy (mean patient age 68 years). The whole roots were initially stored frozen at -186 degrees C, then shipped packed on dry ice. After complete thawing, the roots were pressurized whole; test strips were then cut from the valve cusps, roots and sinuses and tested for stress/strain, stress relaxation, and ultimate failure strength. The pulmonary roots were more distensible (30% versus 20% strain to lock-up) and less compliant when loaded to aortic pressures. The pulmonary valve cusp and root tissue also showed greater extensibility and greater stiffness (lower compliance) when subjected to the same loads. We conclude that mechanical differences between aortic and pulmonary valve tissues are minimal. The pulmonary root should withstand the forces imposed on it when placed in the aortic position. However, if implanted whole, the pulmonary root will distend about 30% more than the aortic root when subjected to aortic pressures. These geometric changes may affect valve function in the long term and should be appreciated when implanting a pulmonary valve graft.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Toma, Milan; Jensen, Morten Ø.; Einstein, Daniel R.
2015-07-17
Numerical models of native heart valves are being used to study valve biomechanics to aid design and development of repair procedures and replacement devices. These models have evolved from simple two-dimensional approximations to complex three-dimensional, fully coupled fluid-structure interaction (FSI) systems. Such simulations are useful for predicting the mechanical and hemodynamic loading on implanted valve devices. A current challenge for improving the accuracy of these predictions is choosing and implementing modeling boundary conditions. In order to address this challenge, we are utilizing an advanced in-vitro system to validate FSI conditions for the mitral valve system. Explanted ovine mitral valves weremore » mounted in an in vitro setup, and structural data for the mitral valve was acquired with *CT. Experimental data from the in-vitro ovine mitral valve system were used to validate the computational model. As the valve closes, the hemodynamic data, high speed lea et dynamics, and force vectors from the in-vitro system were compared to the results of the FSI simulation computational model. The total force of 2.6 N per papillary muscle is matched by the computational model. In vitro and in vivo force measurements are important in validating and adjusting material parameters in computational models. The simulations can then be used to answer questions that are otherwise not possible to investigate experimentally. This work is important to maximize the validity of computational models of not just the mitral valve, but any biomechanical aspect using computational simulation in designing medical devices.« less
Toma, Milan; Jensen, Morten Ø; Einstein, Daniel R; Yoganathan, Ajit P; Cochran, Richard P; Kunzelman, Karyn S
2016-04-01
Numerical models of native heart valves are being used to study valve biomechanics to aid design and development of repair procedures and replacement devices. These models have evolved from simple two-dimensional approximations to complex three-dimensional, fully coupled fluid-structure interaction (FSI) systems. Such simulations are useful for predicting the mechanical and hemodynamic loading on implanted valve devices. A current challenge for improving the accuracy of these predictions is choosing and implementing modeling boundary conditions. In order to address this challenge, we are utilizing an advanced in vitro system to validate FSI conditions for the mitral valve system. Explanted ovine mitral valves were mounted in an in vitro setup, and structural data for the mitral valve was acquired with [Formula: see text]CT. Experimental data from the in vitro ovine mitral valve system were used to validate the computational model. As the valve closes, the hemodynamic data, high speed leaflet dynamics, and force vectors from the in vitro system were compared to the results of the FSI simulation computational model. The total force of 2.6 N per papillary muscle is matched by the computational model. In vitro and in vivo force measurements enable validating and adjusting material parameters to improve the accuracy of computational models. The simulations can then be used to answer questions that are otherwise not possible to investigate experimentally. This work is important to maximize the validity of computational models of not just the mitral valve, but any biomechanical aspect using computational simulation in designing medical devices.
Brandão, Tatiana J D; Januario-da-Silva, Carolina A; Correia, Marcelo G; Zappa, Monica; Abrantes, Jaime A; Dantas, Angela M R; Golebiovski, Wilma; Barbosa, Giovanna Ianini F; Weksler, Clara; Lamas, Cristiane C
2017-04-01
Infective endocarditis (IE) is a severe disease. Pathogen isolation is fundamental so as to treat effectively and reduce morbidity and mortality. Blood and valve culture and histopathology (HP) are routinely employed for this purpose. Valve HP is the gold standard for diagnosis. To determine the sensitivity and specificity of clinical criteria for IE (the modified Duke and the St Thomas' minor modifications, STH) of blood and valve culture compared to valve HP, and to evaluate antibiotic treatment duration. Prospective case series of patients, from 2006 to 2014 with surgically treated IE. Statistical analysis was done by the R software. There were 136 clinically definite episodes of IE in 133 patients. Mean age ± SD was 43 ± 15.6 years and IE was left sided in 81.6 %. HP was definite in 96 valves examined, which were used as gold standard. Sensitivity of blood culture was 61 % (CI 0.51, 0.71) and of valve culture 15 % (CI 0.07, 0.26). The modified Duke criteria were 65 % (CI 0.55, 0.75) sensitive and 33 % specific, while the STH's sensitivity was 72 % (CI 0.61, 0.80) with similar specificity. In multivariate analysis and logistic regression, the only variable with statistical significance was duration of antibiotic therapy postoperatively. Valve HP had high sensitivity and valve culture low sensitivity in the diagnosis of IE. The STH's criteria were more sensitive than the modified Duke criteria. Valve HP should guide duration of postoperative antibiotic treatment.
Pros and cons of transcatheter aortic valve implantation (TAVI)
Terré, Juan A.; George, Isaac
2017-01-01
Transcatheter aortic valve implantation (TAVI) or replacement (TAVR) was recently approved by the FDA for intermediate risk patients with severe aortic stenosis (AS). This technique was already worldwide adopted for inoperable and high-risk patients. Improved device technology, imaging analysis and operator expertise has reduced the initial worrisome higher complications rate associated with TAVR, making it comparable to surgical aortic valve replacement (SAVR). However, many answers need to be addressed before adoption in lower risk patients. This paper highlights the pros and cons of TAVI based mostly on randomized clinical trials involving the two device platforms approved in the United States. We focused our analysis on metrics that will play a key role in expanding TAVR indication in healthier individuals. We review the significance and gave a perspective on paravalvular leak (PVL), valve performance, valve durability, leaflet thrombosis, stroke and pacemaker requirement. PMID:29062739
Fuel cell system shutdown with anode pressure control
Clingerman, Bruce J.; Doan, Tien M.; Keskula, Donald H.
2002-01-01
A venting methodology and pressure sensing and vent valving arrangement for monitoring anode bypass valve operating during the normal shutdown of a fuel cell apparatus of the type used in vehicle propulsion systems. During a normal shutdown routine, the pressure differential between the anode inlet and anode outlet is monitored in real time in a period corresponding to the normal closing speed of the anode bypass valve and the pressure differential at the end of the closing cycle of the anode bypass valve is compared to the pressure differential at the beginning of the closing cycle. If the difference in pressure differential at the beginning and end of the anode bypass closing cycle indicates that the anode bypass valve has not properly closed, a system controller switches from a normal shutdown mode to a rapid shutdown mode in which the anode inlet is instantaneously vented by rapid vents.
Bekeredjian, Raffi; Bodingbauer, Dorothea; Hofmann, Nina P; Greiner, Sebastian; Schuetz, Moritz; Geis, Nicolas A; Kauczor, Hans U; Bryant, Mark; Chorianopoulos, Emmanuel; Pleger, Sven T; Mereles, Derliz; Katus, Hugo A; Korosoglou, Grigorios
2015-03-01
To investigate if the extent of aortic valve calcification is associated with postprocedural prosthesis eccentricity and paravalvular regurgitation (PAR) in patients undergoing transcatheter aortic valve implantation (TAVI). Cardiac computed tomography angiography (CCTA) was performed before and 3 months after TAVI in 46 patients who received the self-expanding CoreValve and in 22 patients who underwent balloon-expandable Edwards Sapien XT implantation. Aortic annulus calcification was measured with CCTA prior to TAVI and prosthesis eccentricity was assessed with post-TAVI CCTA. Standard echocardiography was also performed in all patients at 3-month follow-up exam. Annulus eccentricity was reduced during TAVI using both implantation systems (from 0.23 ± 0.06 to 0.18 ± 0.07 using CoreValve and from 0.20 ± 0.07 to 0.05 ± 0.03 using Edwards Sapien XT; P<.001 for both). With Edwards Sapien XT, eccentricity reduction at the level of the aortic annulus was significantly higher compared with CoreValve (P<.001). Annulus eccentricity after CoreValve use was significantly related to absolute valve calcification and to valve calcification indexed to body surface area (BSA) (r = 0.48 and 0.50, respectively; P<.001 for both). Furthermore, a significant association was observed between aortic valve calcification and PAR (P<.01 by ANOVA) in patients who received CoreValve. Using ROC analysis, a cut-off value over 913 mm² aortic valve calcification predicted the occurrence of moderate or severe PAR with a sensitivity of 92% and a specificity of 63% (area under the curve = 0.75). Furthermore, multivariable analysis showed that aortic valve calcification was a robust predictor of postprocedural eccentricity and PAR, independent of the aortic annulus size and native valve eccentricity and of CoreValve prosthesis size (adjusted r = 0.46 and 0.50, respectively; P<.01 for both). Such associations were not present with the Edwards Sapien XT system. The extent of native aortic annulus calcification is predictive for postprocedural prosthesis eccentricity and PAR, which is an important marker for long-term mortality in patients undergoing TAVI. This observation applies for the CoreValve, but not for the Edwards Sapien XT valve.
Functional Changes of Diaphragm Type Shunt Valves Induced by Pressure Pulsation
NASA Astrophysics Data System (ADS)
Lee, Chong-Sun; Suh, Chang-Min; Ra, Young-Shin
Shunt valves used to treat patients with hydrocephalus were tested to investigate influence of pressure pulsation on their flow control characteristics. Our focus was on flow dynamic and functional changes of the small and thin diaphragms in the valves that serve as the main flow control mechanism and are made from silicone elastomer. Firstly, pressure-flow control curves were compared under pulsed and steady flow (without pulsation) conditions. Secondly, functional changes of the valves were tested after a long-term continuous pulsation with a peristaltic pump. Thirdly, flushing procedures selectively conducted by neurosurgeons were simulated with a fingertip pressed on the dome of the valves. As 20cc/hr of flow rate was adjusted at a constant pressure, application of 40mmH2O of pressure pulse increased flow rate through shunt valves more than 60%. As a 90cm length silicone catheter was connected to the valve outlet, increase in the flow rate was substantially reduced to 17.5%. Pressure-flow control characteristics of some valves showed significant changes after twenty-eight days of pressure pulsation at 1.0 Hz under 50.0cc/hr of flow rate. Flushing simulation resulted in temporary decrease in the pressure level. It took three hours to fully recover the normal pressure-flow control characteristics after the flushing. Our results suggest that shunt valves with a thin elastic diaphragm as the main flow control mechanism are sensitive to intracranial pressure pulsation or pressure spikes enough to change their pressure-flow control characteristics.
Helder, Meghana R K; Schaff, Hartzell V; Dearani, Joseph A; Li, Zhuo; Stulak, John M; Suri, Rakesh M; Connolly, Heidi M
2014-09-01
The study objective was to evaluate patients with Marfan syndrome and mitral valve regurgitation undergoing valve repair or replacement and to compare them with patients undergoing repair for myxomatous mitral valve disease. We reviewed the medical records of consecutive patients with Marfan syndrome treated surgically between March 17, 1960, and September 12, 2011, for mitral regurgitation and performed a subanalysis of those with repairs compared with case-matched patients with myxomatous mitral valve disease who had repairs (March 14, 1995, to July 5, 2013). Of 61 consecutive patients, 40 underwent mitral repair and 21 underwent mitral replacement (mean [standard deviation] age, 40 [18] vs 31 [19] years; P = .09). Concomitant aortic surgery was performed to a similar extent (repair, 45% [18/40] vs replacement, 43% [9/21]; P = .87). Ten-year survival was significantly better in patients with Marfan syndrome with mitral repair than in those with replacement (80% vs 41%; P = .01). Mitral reintervention did not differ between mitral repair and replacement (cumulative risk of reoperation, 27% vs 15%; P = .64). In the matched cohort, 10-year survival after repair was similar for patients with Marfan syndrome and myxomatous mitral disease (84% vs 78%; P = .63), as was cumulative risk of reoperation (17% vs 12%; P = .61). Patients with Marfan syndrome and mitral regurgitation have better survival with repair than with replacement. Survival and risk of reoperation for patients with Marfan syndrome were similar to those for patients with myxomatous mitral disease. These results support the use of mitral valve repair in patients with Marfan syndrome and moderate or more mitral regurgitation, including those having composite replacement of the aortic root. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Trapeaux, J; Busseuil, D; Shi, Y; Nobari, S; Shustik, D; Mecteau, M; El-Hamamsy, I; Lebel, M; Mongrain, R; Rhéaume, E; Tardif, J-C
2013-01-01
Background and Purpose We have shown that infusions of apolipoprotein A-I (ApoA-I) mimetic peptide induced regression of aortic valve stenosis (AVS) in rabbits. This study aimed at determining the effects of ApoA-I mimetic therapy in mice with calcific or fibrotic AVS. Experimental Approach Apolipoprotein E-deficient (ApoE−/−) mice and mice with Werner progeria gene deletion (WrnΔhel/Δhel) received high-fat diets for 20 weeks. After developing AVS, mice were randomized to receive saline (placebo group) or ApoA-I mimetic peptide infusions (ApoA-I treated groups, 100 mg·kg−1 for ApoE−/− mice; 50 mg·kg−1 for Wrn mice), three times per week for 4 weeks. We evaluated effects on AVS using serial echocardiograms and valve histology. Key Results Aortic valve area (AVA) increased in both ApoE−/− and Wrn mice treated with the ApoA-I mimetic compared with placebo. Maximal sinus wall thickness was lower in ApoA-I treated ApoE−/− mice. The type I/III collagen ratio was lower in the sinus wall of ApoA-I treated ApoE−/− mice compared with placebo. Total collagen content was reduced in aortic valves of ApoA-I treated Wrn mice. Our 3D computer model and numerical simulations confirmed that the reduction in aortic root wall thickness resulted in improved AVA. Conclusions and Implications ApoA-I mimetic treatment reduced AVS by decreasing remodelling and fibrosis of the aortic root and valve in mice. PMID:23638718
Côté, Nancy; Simard, Louis; Zenses, Anne-Sophie; Tastet, Lionel; Shen, Mylène; Clisson, Marine; Clavel, Marie-Annick
2017-07-07
About 50% of normal-flow/low-gradient patients (ie, low mean gradient [MG] or peak aortic jet velocity and small aortic valve area) have severe aortic valve calcification as measured by computed tomography. However, they are considered to have moderate aortic stenosis (AS) in current American College of Cardiology/American Heart Association guidelines. The objective was thus to evaluate the effect of hypertension and reduced arterial compliance (rAC) on MG and V peak measurements. Doppler-echocardiography was performed in 4 sheep with experimentally induced severe and critical AS at: (1) normal aortic pressure, (2) during hypertension, and (3) with rAC. Hypertension and rAC induced a substantial decrease in MG/V peak compared with normal stage (both P ≤0.03) despite a stable transvalvular flow ( P >0.16). Hypertension and rAC resulted in a greater reduction of MG in critical (-42%) compared with severe (-35%) AS ( P ˂0.0001). Comprehensive Doppler-echocardiography and computed tomography were performed in 220 AS patients (mean age: 69±13 years; MG 29±18 mm Hg) with normal flow. The population was divided in 3 groups according to the presence of hypertension and rAC. The slope of the linear association between MG/V peak and aortic valve calcification divided by the cross-sectional area of the aortic annulus was significantly reduced in patients with hypertension and/or rAC compared with normotensive/normal AC patients ( P <0.01). Accordingly, patients with normal-flow/low-gradient and severe aortic valve calcification density were more frequent in hypertension and rAC groups compared with the normotensive/normal-AC group (16% and 12% compared with 2%; P =0.03). Hypertension and rAC are associated with a substantial reduction in MG/V peak for similar aortic valve calcification (ie, similar AS anatomic severity), which may lead to underestimation of AS hemodynamic severity. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Roos, Carolyn M.; Hagler, Michael; Zhang, Bin; Oehler, Elise A.; Arghami, Arman
2013-01-01
The purpose of this study was to characterize changes in antioxidant and age-related gene expression in aorta and aortic valve with aging, and test the hypothesis that increased mitochondrial oxidative stress accelerates age-related endothelial and aortic valve dysfunction. Wild-type (MnSOD+/+) and manganese SOD heterozygous haploinsufficient (MnSOD+/−) mice were studied at 3 and 18 mo of age. In aorta from wild-type mice, antioxidant expression was preserved, although there were age-associated increases in Nox2 expression. Haploinsufficiency of MnSOD did not alter antioxidant expression in aorta, but increased expression of Nox2. When compared with that of aorta, age-associated reductions in antioxidant expression were larger in aortic valves from wild-type and MnSOD haploinsufficient mice, although Nox2 expression was unchanged. Similarly, sirtuin expression was relatively well-preserved in aorta from both genotypes, whereas expression of SIRT1, SIRT2, SIRT3, SIRT4, and SIRT6 were significantly reduced in the aortic valve. Expression of p16ink4a, a marker of cellular senescence, was profoundly increased in both aorta and aortic valve from MnSOD+/+ and MnSOD+/− mice. Functionally, we observed comparable age-associated reductions in endothelial function in aorta from both MnSOD+/+ and MnSOD+/− mice. Interestingly, inhibition of NAD(P)H oxidase with apocynin or gp91ds-tat improved endothelial function in MnSOD+/+ mice but significantly impaired endothelial function in MnSOD+/− mice at both ages. Aortic valve function was not impaired by aging or MnSOD haploinsufficiency. Changes in antioxidant and sirtuin gene expression with aging differ dramatically between aorta and aortic valve. Furthermore, although MnSOD does not result in overt cardiovascular dysfunction with aging, compensatory transcriptional responses to MnSOD deficiency appear to be tissue specific. PMID:23997094
Aortic valve function after bicuspidization of the unicuspid aortic valve.
Aicher, Diana; Bewarder, Moritz; Kindermann, Michael; Abdul-Khalique, Hashim; Schäfers, Hans-Joachim
2013-05-01
Unicuspid aortic valve (UAV) anatomy leads to dysfunction of the valve in young individuals. We introduced a reconstructive technique of bicuspidizing the UAV. Initially we copied the typical asymmetry of a normal bicuspid aortic valve (BAV) (I), later we created a symmetric BAV (II). This study compared the hemodynamic function of the two designs of a bicuspidized UAV. Aortic valve function was studied at rest and during exercise in 28 patients after repair of UAV (group I, n = 8; group II, n = 20). There were no differences among the groups I and II with respect to gender, age, body size, or weight. All patients were in New York Heart Association class I. Six healthy adults served as control individuals. All patients were studied with transthoracic echocardiography between 4 and 65 months postoperatively. Systolic gradients were assessed by continuous wave Doppler while patients were at rest and exercising on a bicycle ergometer. Aortic regurgitation was grade I or less in all patients. Resting gradients were significantly elevated in group I compared with group II and control individuals (group I, peak 33.8 ± 7.8 mm Hg; mean 19.1 ± 5.4 mm Hg; group II, peak 15.8 ± 5.4, mean 8.2 ± 2.8 mm Hg; control individuals, peak 6.0 ± 1.6, mean 3.2 ± 0.8 mm Hg; p < 0.001). At 100 W peak gradients were highest in group I (group I, 62.7 ± 16.7 mm Hg; group II, 28.1 ± 7.6 mm Hg; control individuals, 15.4 ± 4.6 mm Hg; p < 0.001). Converting a UAV into a symmetric bicuspid design results in adequate valve competence. A symmetric repair design leads to improved systolic aortic valve function at rest and during exercise. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
2013-01-01
Background Sclerostin is a Wnt pathway antagonist regulating osteoblast activity and bone turnover. Here, we assessed the potential association of sclerostin with the development of coronary artery (CAC) and aortic valve calcifications (AVC) in haemodialysis (HD) patients. Methods We conducted a cross-sectional multi-slice computed tomography (MS-CT) scanning study in 67 chronic HD patients (59.4 ± 14.8 yrs) for measurement of CAC and AVC. We tested established biomarkers as well as serum sclerostin (ELISA) regarding their association to the presence of calcification. Fifty-four adults without relevant renal disease served as controls for serum sclerostin levels. Additionally, sclerostin expression in explanted aortic valves from 15 dialysis patients was analysed ex vivo by immunohistochemistry and mRNA quantification (Qt-RT-PCR). Results CAC (Agatston score > 100) and any AVC were present in 65% and in 40% of the MS-CT patient group, respectively. Serum sclerostin levels (1.53 ± 0.81 vs 0.76 ± 0.31 ng/mL, p < 0.001) were significantly elevated in HD compared to controls and more so in HD patients with AVC versus those without AVC (1.78 ± 0.84 vs 1.35 ± 0.73 ng/mL, p = 0.02). Multivariable regression analysis for AVC revealed significant associations with higher serum sclerostin. Ex vivo analysis of uraemic calcified aortic valves (n = 10) revealed a strong sclerostin expression very close to calcified regions (no sclerostin staining in non-calcified valves). Correspondingly, we observed a highly significant upregulation of sclerostin mRNA in calcified valves compared to non-calcified control valves. Conclusion We found a strong association of sclerostin with calcifying aortic heart valve disease in haemodialysis patients. Sclerostin is locally produced in aortic valve tissue adjacent to areas of calcification. PMID:24112318
Shuvy, Mony; Abedat, Suzan; Beeri, Ronen; Danenberg, Haim D.; Planer, David; Ben-Dov, Iddo Z.; Meir, Karen; Sosna, Jacob; Lotan, Chaim
2008-01-01
Aims Renal failure is associated with aortic valve calcification (AVC). Our aim was to develop an animal model for exploring the pathophysiology and reversibility of AVC, utilizing rats with diet-induced kidney disease. Methods and results Sprague–Dawley rats (n = 23) were fed a phosphate-enriched, uraemia-inducing diet for 7 weeks followed by a normal diet for 2 weeks (‘diet group’). These rats were compared with normal controls (n = 10) and with uraemic controls fed with phosphate-depleted diet (‘low-phosphate group’, n = 10). Clinical investigations included serum creatinine, phosphate and parathyroid hormone (PTH) levels, echocardiography, and multislice computed tomography. Pathological examinations of the valves included histological characterization, Von Kossa staining, and antigen and gene expression analyses. Eight diet group rats were further assessed for reversibility of valve calcification following normalization of their kidney function. At 4 weeks, all diet group rats developed renal failure and hyperparathyroidism. At week 9, renal failure resolved with improvement in the hyperparathyroid state. Echocardiography demonstrated valve calcifications only in diet group rats. Tomographic calcium scores were significantly higher in the diet group compared with controls. Von Kossa stain in diet group valves revealed calcium deposits, positive staining for osteopontin, and CD68. Gene expression analyses revealed overexpression of osteoblast genes and nuclear factor κB activation. Valve calcification resolved after diet cessation in parallel with normalization of PTH levels. Resolution was associated with down-regulation of inflammation and osteoblastic features. Low-phosphate group rats developed kidney dysfunction similar to that of the diet group but with normal levels of PTH. Calcium scores and histology showed only minimal valve calcification. Conclusion We developed an animal model for AVC. The process is related to disturbed mineral metabolism. It is associated with inflammation and osteoblastic features. Furthermore, the process is reversible upon normalization of the mineral homeostasis. Thus, our model constitutes a convenient platform for studying AVC and potential remedies. PMID:18390899
Shuvy, Mony; Abedat, Suzan; Beeri, Ronen; Danenberg, Haim D; Planer, David; Ben-Dov, Iddo Z; Meir, Karen; Sosna, Jacob; Lotan, Chaim
2008-08-01
Renal failure is associated with aortic valve calcification (AVC). Our aim was to develop an animal model for exploring the pathophysiology and reversibility of AVC, utilizing rats with diet-induced kidney disease. Sprague-Dawley rats (n = 23) were fed a phosphate-enriched, uraemia-inducing diet for 7 weeks followed by a normal diet for 2 weeks ('diet group'). These rats were compared with normal controls (n = 10) and with uraemic controls fed with phosphate-depleted diet ('low-phosphate group', n = 10). Clinical investigations included serum creatinine, phosphate and parathyroid hormone (PTH) levels, echocardiography, and multislice computed tomography. Pathological examinations of the valves included histological characterization, Von Kossa staining, and antigen and gene expression analyses. Eight diet group rats were further assessed for reversibility of valve calcification following normalization of their kidney function. At 4 weeks, all diet group rats developed renal failure and hyperparathyroidism. At week 9, renal failure resolved with improvement in the hyperparathyroid state. Echocardiography demonstrated valve calcifications only in diet group rats. Tomographic calcium scores were significantly higher in the diet group compared with controls. Von Kossa stain in diet group valves revealed calcium deposits, positive staining for osteopontin, and CD68. Gene expression analyses revealed overexpression of osteoblast genes and nuclear factor kappaB activation. Valve calcification resolved after diet cessation in parallel with normalization of PTH levels. Resolution was associated with down-regulation of inflammation and osteoblastic features. Low-phosphate group rats developed kidney dysfunction similar to that of the diet group but with normal levels of PTH. Calcium scores and histology showed only minimal valve calcification. We developed an animal model for AVC. The process is related to disturbed mineral metabolism. It is associated with inflammation and osteoblastic features. Furthermore, the process is reversible upon normalization of the mineral homeostasis. Thus, our model constitutes a convenient platform for studying AVC and potential remedies.
Semi-automation of Doppler Spectrum Image Analysis for Grading Aortic Valve Stenosis Severity.
Niakšu, O; Balčiunaitė, G; Kizlaitis, R J; Treigys, P
2016-01-01
Doppler echocardiography analysis has become a golden standard in the modern diagnosis of heart diseases. In this paper, we propose a set of techniques for semi-automated parameter extraction for aortic valve stenosis severity grading. The main objectives of the study is to create echocardiography image processing techniques, which minimize manual image processing work of clinicians and leads to reduced human error rates. Aortic valve and left ventricle output tract spectrogram images have been processed and analyzed. A novel method was developed to trace systoles and to extract diagnostic relevant features. The results of the introduced method have been compared to the findings of the participating cardiologists. The experimental results showed the accuracy of the proposed method is comparable to the manual measurement performed by medical professionals. Linear regression analysis of the calculated parameters and the measurements manually obtained by the cardiologists resulted in the strongly correlated values: peak systolic velocity's and mean pressure gradient's R2 both equal to 0.99, their means' differences equal to 0.02 m/s and 4.09 mmHg, respectively, and aortic valve area's R2 of 0.89 with the two methods means' difference of 0.19 mm. The introduced Doppler echocardiography images processing method can be used as a computer-aided assistance in the aortic valve stenosis diagnostics. In our future work, we intend to improve precision of left ventricular outflow tract spectrogram measurements and apply data mining methods to propose a clinical decision support system for diagnosing aortic valve stenosis.
Saida, Yuuto; Tanaka, Ryou; Fukushima, Ryuji; Hoshi, Katsuichiro; Hira, Satoshi; Soda, Aiko; Iizuka, Tomoya; Ishikawa, Taisuke; Nishimura, Taiki; Yamane, Yoshihisa
2009-04-01
Right ventricle (RV)-pulmonary artery (PA) valved conduit (RPVC) implantation decreases RV systolic pressure in pulmonic stenosis (PS) by forming a bypass route between the RV and the PA. The present study evaluates valved conduits derived from canine aortae in a canine model of PS produced by pulmonary artery banding (PAB). Pulmonary stenosis was elicited using PAB in 10 conditioned beagles aged 8 months. Twelve weeks after PAB, the dogs were assigned to one group that did not undergo surgical intervention and another that underwent RPVC using denacol-treated canine aortic valved grafts (PAB+RPVC). Twelve weeks later, the rate of change in the RV-PA systolic pressure gradient was significantly decreased in the PAB+RPVC, compared with the PAB group (60.5 +/- 16.7% vs. 108.9 +/- 22.9%; p<0.01). In addition, the end-diastolic RV free wall thickness (RVFWd) was significantly reduced in the PAB+RPVC, compared with the PAB group (8.2 +/- 0.2 vs. 9.4 +/- 0.7 mm; p<0.05). Thereafter, regurgitation was not evident beyond the conduit valve and the decrease in RV pressure overload induced by RPVC was confirmed. The present results indicate that RPVC can be performed under a beating heart without cardiopulmonary bypass and adapted to dogs with various types of PS, including "supra valvular" PS or PS accompanied by dysplasia of the pulmonary valve. Therefore, we consider that this method is useful for treating PS in small animals.
Monolithic Teflon membrane valves and pumps for harsh chemical and low-temperature use.
Willis, Peter A; Hunt, Brian D; White, Victor E; Lee, Michael C; Ikeda, Michael; Bae, Sam; Pelletier, Michael J; Grunthaner, Frank J
2007-11-01
Microfluidic diaphragm valves and pumps capable of surviving conditions required for unmanned spaceflight applications have been developed. The Pasteur payload of the European ExoMars Rover is expected to experience temperatures ranging between -100 degrees C and +50 degrees C during its transit to Mars and on the Martian surface. As such, the Urey instrument package, which contains at its core a lab-on-a-chip capillary electrophoresis analysis system first demonstrated by Mathies et al., requires valving and pumping systems that are robust under these conditions before and after exposure to liquid samples, which are to be analyzed for chemical signatures of past or present living processes. The microfluidic system developed to meet this requirement uses membranes consisting of Teflon and Teflon AF as a deformable material in the valve seat region between etched Borofloat glass wafers. Pneumatic pressure and vacuum, delivered via off-chip solenoid valves, are used to actuate individual on-chip valves. Valve sealing properties of Teflon diaphragm valves, as well as pumping properties from collections of valves, are characterized. Secondary processing for embossing the membrane against the valve seats after fabrication is performed to optimize single valve sealing characteristics. A variety of different material solutions are found to produce robust devices. The optimal valve system utilizes a membrane of mechanically cut Teflon sandwiched between two thin spun films of Teflon AF-1600 as a composite "laminated" diaphragm. Pump rates up to 1600 nL s(-1) are achieved with pumps of this kind. These high pumping rates are possible because of the very fast response of the membranes to applied pressure, enabling extremely fast pump cycling with relatively small liquid volumes, compared to analogous diaphragm pumps. The developed technologies are robust over extremes of temperature cycling and are applicable in a wide range of chemical environments.
Ugur, Murat; Byrne, John G; Bavaria, Joseph E; Cheung, Anson; Petracek, Michael; Groh, Mark A; Suri, Rakesh M; Borger, Michael A; Schaff, Hartzell V
2014-10-01
The study objective was to evaluate whether aortic valve replacement with the Trifecta valve (St Jude Medical Inc, St Paul, Minn) using simple sutures produces better hemodynamic performance than valve replacement with noneverting pledget-reinforced sutures. We analyzed prospectively acquired 1-year hemodynamic data of patients with small aortic annulus sizes who were enrolled in a multicenter trial of the Trifecta aortic valve bioprosthesis and underwent aortic valve replacement with a 19-mm or 21-mm bioprosthesis between August 2007 and November 2009. We compared preoperative clinical information and 1-year postoperative hemodynamic data for noneverting pledget-reinforced sutures (group 1) versus everting mattress sutures or simple sutures (group 2). A total of 346 patients underwent aortic valve replacement: 269 in group 1 and 77 in group 2. Preoperative demographic characteristics for the 2 groups were similar. For groups 1 and 2, the mean gradient was 10.4±4.7 mm Hg and 11.1±4.4 mm Hg for 19-mm valves, respectively, and 8.4±3.5 mm Hg and 8.8±3.6 mm Hg for 21-mm valves, respectively; the effective orifice area was 1.40 cm2 and 1.25 cm2 for 19-mm valves, respectively, and 1.57 cm2 and 1.50 cm2 for 21-mm valves, respectively. The rate of severe prosthesis-patient mismatch (indexed effective orifice area≤0.65 cm2/m2) was 18.6% (n=11) and 25% (n=6) for 19-mm valves, respectively, and 10.9% (n=20) and 16.3% (n=8) for 21-mm valves, respectively. The suture method did not affect hemodynamic performance of supra-annular bioprostheses in patients with small aortic annulus sizes. Choice of suture technique should be determined by surgeon experience and local anatomic features. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
High Temperature Solid Lubricant Materials for Heavy Duty and Advanced Heat Engines
NASA Technical Reports Server (NTRS)
Dellacorte, C.; Wood, J. C.
1994-01-01
Advanced engine designs incorporate higher mechanical and thermal loading to achieve efficiency improvements. This approach often leads to higher operating temperatures of critical sliding elements (e.g. piston ring/cylinder wall contacts and valve guides) which compromise the use of conventional and even advanced synthetic liquid lubricants. For these applications solid lubricants must be considered. Several novel solid lubricant composites and coatings designated PS/PM200 have been employed to dry and marginally oil lubricated contacts in advanced heat engines. These applications include cylinder kits of heavy duty diesels, and high temperature Stirling engines, sidewall seals of rotary engines, and various exhaust valve and exhaust component applications. This paper describes the tribological and thermophysical properties of these tribomaterials and reviews the results of applying them to engine applications. Other potential tribological materials and applications are also discussed with particular emphasis on heavy duty and advanced heat engines.
Mean flow and noise measurements in a Mach 3.5 pilot quiet tunnel
NASA Technical Reports Server (NTRS)
Beckwith, I. E.; Moore, W. O., III
1982-01-01
The use of Mach 3.5 two-dimensional rapid expansion nozzle for wind tunnel testing at supersonic speeds and low noise conditions encountered in high altitude flights is described. The supersonic pilot quiet tunnel is located at the NASA Langley Research Center and a description of the facility is provided, along with instrumentation and noise measurement test data at 30, 50, and 75 psia. The mean pitot pressure distributions, rms noise levels, the effect of unit Reynolds number, wall waviness, wall contaminants, and the effects of closing the bleed valve are analyzed. Typical laminar and turbulent spectra are presented, along with a summary of the effect of slot throat adjustment on the power spectra. Comparisons are made of the power spectra with the bleed valve open and closed, and of the rms fluctuating pressures with levels from conventional nozzles, and the performance capabilities are evaluated for use in transition studies.
Sabbuba, N A; Stickler, D J; Long, M J; Dong, Z; Short, T D; Feneley, R J C
2005-01-01
We tested whether valve regulated, intermittent flow of urine from catheterized bladders decreases catheter encrustation. Laboratory models of the catheterized bladder were infected with Proteus mirabilis. Urine was allowed to drain continuously through the catheters or regulated by valves to drain intermittently at predetermined intervals. The time that catheters required to become blocked was recorded and encrustation was visualized by scanning electron microscopy. When a manual valve was used to drain urine from the bladder at 2-hour intervals 4 times during the day, catheters required significantly longer to become blocked than those on continuous drainage (mean 62.6 vs 35.9 hours, p = 0.039). A similar 1.7-fold increase occurred when urine was drained at 4-hour intervals 3 times daily. Experiments with an automatic valve in which urine was released at 2 or 4-hour intervals through the day and night also showed a significant increase in mean time to blockage compared with continuous drainage (p = 0.001). Scanning electron microscopy confirmed that crystalline biofilm was less extensive on valve regulated catheters. Valve regulated, intermittent flow of urine through catheters increases the time that catheters require to become blocked with crystalline biofilm. The most beneficial effect was recorded when urine was released from the bladder at 4-hour intervals throughout the day and night by an automatic valve.
Fluid-structure interaction analysis of the flow through a stenotic aortic valve
NASA Astrophysics Data System (ADS)
Maleki, Hoda; Labrosse, Michel R.; Durand, Louis-Gilles; Kadem, Lyes
2009-11-01
In Europe and North America, aortic stenosis (AS) is the most frequent valvular heart disease and cardiovascular disease after systemic hypertension and coronary artery disease. Understanding blood flow through an aortic stenosis and developing new accurate non-invasive diagnostic parameters is, therefore, of primarily importance. However, simulating such flows is highly challenging. In this study, we considered the interaction between blood flow and the valve leaflets and compared the results obtained in healthy valves with stenotic ones. One effective method to model the interaction between the fluid and the structure is to use Arbitrary Lagrangian-Eulerian (ALE) approach. Our two-dimensional model includes appropriate nonlinear and anisotropic materials. It is loaded during the systolic phase by applying pressure curves to the fluid domain at the inflow. For modeling the calcified stenotic valve, calcium will be added on the aortic side of valve leaflets. Such simulations allow us to determine the effective orifice area of the valve, one of the main parameters used clinically to evaluate the severity of an AS, and to correlate it with changes in the structure of the leaflets.
The role of visual and direct force feedback in robotics-assisted mitral valve annuloplasty.
Currie, Maria E; Talasaz, Ali; Rayman, Reiza; Chu, Michael W A; Kiaii, Bob; Peters, Terry; Trejos, Ana Luisa; Patel, Rajni
2017-09-01
The objective of this work was to determine the effect of both direct force feedback and visual force feedback on the amount of force applied to mitral valve tissue during ex vivo robotics-assisted mitral valve annuloplasty. A force feedback-enabled master-slave surgical system was developed to provide both visual and direct force feedback during robotics-assisted cardiac surgery. This system measured the amount of force applied by novice and expert surgeons to cardiac tissue during ex vivo mitral valve annuloplasty repair. The addition of visual (2.16 ± 1.67), direct (1.62 ± 0.86), or both visual and direct force feedback (2.15 ± 1.08) resulted in lower mean maximum force applied to mitral valve tissue while suturing compared with no force feedback (3.34 ± 1.93 N; P < 0.05). To achieve better control of interaction forces on cardiac tissue during robotics-assisted mitral valve annuloplasty suturing, force feedback may be required. Copyright © 2016 John Wiley & Sons, Ltd.
In vivo canine studies of a Sinkhole valve and vascular graft coated with biocompatible PU-PEO-SO3.
Han, D K; Lee, K B; Park, K D; Kim, C S; Jeong, S Y; Kim, Y H; Kim, H M; Min, B G
1993-01-01
PU-PEO-SO3 was applied as a coating material over a newly designed Sinkhole bileaflet PU heart valve and a porous PU vascular graft. Performance and biocompatibility were evaluated using an in vivo canine shunt system between the right ventricle and pulmonary artery. The survival periods in three implantations were 14, 24, and 39 days, during which no mechanical failure occurred in any Sinkhole valve or vascular graft. Scanning electron microscopy (SEM) studies demonstrated much less platelet adhesion and thrombus formation on PU-PEO-SO3 grafts than on PU vascular grafts. Cracks in the valve leaflet were occasionally observed on PU surfaces, but not on PU-PEO-SO3. After a 39 day implantation, calcium deposition on vascular grafts was decreased as compared with valve leaflets, and calcification on PU-PEO-SO3 was much lower than on PU. These results suggest that Sinkhole valves and vascular grafts are promising, and PU-PEO-SO3 as a coating material is more blood compatible, biostable, and calcification resistant in vivo than in untreated PU.
Shirokawa, Yuka; Shimada, Masakazu
2016-11-16
In cytoplasmic inheritance, structural states of a parent cell could be transmitted to offspring cells via two mechanisms. The first is referred to as the hangover of parent structure, where the structure itself remains and faithfully transmits within offspring cells; the second is structural inheritance, wherein the parent structure functions as a template for development of new offspring structure. We estimated to what extent the parent structure affects the development of offspring structure by structural inheritance, using a clone of the diatom Cyclotella meneghiniana The cell has two siliceous valves (a cell wall part at both cell poles): one is inherited from the parent and the other is newly formed. We estimated cytoplasmic heritability by comparing valve traits (central fultoportulae (CTFP), striae, central area, and cell diameter) of parent and new offspring valves, using single-cell isolation and valve labelling. Parent-offspring valve trait regressions showed that all traits, except CTFP, were significantly correlated. We formulated a quantitative genetic model considering the diatom inheritance system and revealed short-term rapid evolution compared with other inheritance systems. Diatom structural inheritance will have evolved to enable clonal populations to rapidly acquire and maintain suitable structures for temporal changes in environments and life-cycle stages. © 2016 The Author(s).
Exercise-based cardiac rehabilitation for adults after heart valve surgery.
Sibilitz, Kirstine L; Berg, Selina K; Tang, Lars H; Risom, Signe S; Gluud, Christian; Lindschou, Jane; Kober, Lars; Hassager, Christian; Taylor, Rod S; Zwisler, Ann-Dorthe
2016-03-21
Exercise-based cardiac rehabilitation may benefit heart valve surgery patients. We conducted a systematic review to assess the evidence for the use of exercise-based intervention programmes following heart valve surgery. To assess the benefits and harms of exercise-based cardiac rehabilitation compared with no exercise training intervention, or treatment as usual, in adults following heart valve surgery. We considered programmes including exercise training with or without another intervention (such as a psycho-educational component). We searched: the Cochrane Central Register of Controlled Trials (CENTRAL); the Database of Abstracts of Reviews of Effects (DARE); MEDLINE (Ovid); EMBASE (Ovid); CINAHL (EBSCO); PsycINFO (Ovid); LILACS (Bireme); and Conference Proceedings Citation Index-S (CPCI-S) on Web of Science (Thomson Reuters) on 23 March 2015. We handsearched Web of Science, bibliographies of systematic reviews and trial registers (ClinicalTrials.gov, Controlled-trials.com, and The World Health Organization International Clinical Trials Registry Platform). We included randomised clinical trials that investigated exercise-based interventions compared with no exercise intervention control. The trial participants comprised adults aged 18 years or older who had undergone heart valve surgery for heart valve disease (from any cause) and received either heart valve replacement, or heart valve repair. Two authors independently extracted data. We assessed the risk of systematic errors ('bias') by evaluation of bias risk domains. Clinical and statistical heterogeneity were assessed. Meta-analyses were undertaken using both fixed-effect and random-effects models. We used the GRADE approach to assess the quality of evidence. We sought to assess the risk of random errors with trial sequential analysis. We included two trials from 1987 and 2004 with a total 148 participants who have had heart valve surgery. Both trials had a high risk of bias.There was insufficient evidence at 3 to 6 months follow-up to judge the effect of exercise-based cardiac rehabilitation compared to no exercise on mortality (RR 4.46 (95% confidence interval (CI) 0.22 to 90.78); participants = 104; studies = 1; quality of evidence: very low) and on serious adverse events (RR 1.15 (95% CI 0.37 to 3.62); participants = 148; studies = 2; quality of evidence: very low). Included trials did not report on health-related quality of life (HRQoL), and the secondary outcomes of New York Heart Association class, left ventricular ejection fraction and cost. We did find that, compared with control (no exercise), exercise-based rehabilitation may increase exercise capacity (SMD -0.47, 95% CI -0.81 to -0.13; participants = 140; studies = 2, quality of evidence: moderate). There was insufficient evidence at 12 months follow-up for the return to work outcome (RR 0.55 (95% CI 0.19 to 1.56); participants = 44; studies = 1; quality of evidence: low). Due to limited information, trial sequential analysis could not be performed as planned. Our findings suggest that exercise-based rehabilitation for adults after heart valve surgery, compared with no exercise, may improve exercise capacity. Due to a lack of evidence, we cannot evaluate the impact on other outcomes. Further high-quality randomised clinical trials are needed in order to assess the impact of exercise-based rehabilitation on patient-relevant outcomes, including mortality and quality of life.
Reynolds, Matthew R; Lei, Yang; Wang, Kaijun; Chinnakondepalli, Khaja; Vilain, Katherine A; Magnuson, Elizabeth A; Galper, Benjamin Z; Meduri, Christopher U; Arnold, Suzanne V; Baron, Suzanne J; Reardon, Michael J; Adams, David H; Popma, Jeffrey J; Cohen, David J
2016-01-05
Previous studies of the cost-effectiveness of transcatheter aortic valve replacement (TAVR) have been based primarily on a single balloon-expandable system. The goal of this study was to evaluate the cost-effectiveness of TAVR with a self-expanding prosthesis compared with surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis and high surgical risk. We performed a formal economic analysis on the basis of individual, patient-level data from the CoreValve U.S. High Risk Pivotal Trial. Empirical data regarding survival and quality of life over 2 years, and medical resource use and hospital costs through 12 months were used to project life expectancy, quality-adjusted life expectancy, and lifetime medical costs in order to estimate the incremental cost-effectiveness of TAVR versus SAVR from a U.S. Relative to SAVR, TAVR reduced initial length of stay an average of 4.4 days, decreased the need for rehabilitation services at discharge, and resulted in superior 1-month quality of life. Index admission and projected lifetime costs were higher with TAVR than with SAVR (differences $11,260 and $17,849 per patient, respectively), whereas TAVR was projected to provide a lifetime gain of 0.32 quality-adjusted life-years ([QALY]; 0.41 LY) with 3% discounting. Lifetime incremental cost-effectiveness ratios were $55,090 per QALY gained and $43,114 per LY gained. Sensitivity analyses indicated that a reduction in the initial cost of TAVR by ∼$1,650 would lead to an incremental cost-effectiveness ratio <$50,000/QALY gained. In a high-risk clinical trial population, TAVR with a self-expanding prosthesis provided meaningful clinical benefits compared with SAVR, with incremental costs considered acceptable by current U.S. With expected modest reductions in the cost of index TAVR admissions, the value of TAVR compared with SAVR in this patient population would become high. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement [Medtronic CoreValve U.S. Pivotal Trial]; NCT01240902). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.