A white dwarf cooling age of 8 Gyr for NGC 6791 from physical separation processes.
García-Berro, Enrique; Torres, Santiago; Althaus, Leandro G; Renedo, Isabel; Lorén-Aguilar, Pablo; Córsico, Alejandro H; Rohrmann, René D; Salaris, Maurizio; Isern, Jordi
2010-05-13
NGC 6791 is a well studied open cluster that it is so close to us that can be imaged down to very faint luminosities. The main-sequence turn-off age ( approximately 8 Gyr) and the age derived from the termination of the white dwarf cooling sequence ( approximately 6 Gyr) are very different. One possible explanation is that as white dwarfs cool, one of the ashes of helium burning, (22)Ne, sinks in the deep interior of these stars. At lower temperatures, white dwarfs are expected to crystallize and phase separation of the main constituents of the core of a typical white dwarf ((12)C and (16)O) is expected to occur. This sequence of events is expected to introduce long delays in the cooling times, but has not hitherto been proven. Here we report that, as theoretically anticipated, physical separation processes occur in the cores of white dwarfs, resolving the age discrepancy for NGC 6791.
Cool circumstellar matter around nearby main-sequence stars
NASA Technical Reports Server (NTRS)
Walker, H. J.; Wolstencroft, R. D.
1988-01-01
Stars are presented which have characteristics similar to Vega and other main-sequence stars with cool dust disks, based on the IRAS Point Source Catalog fluxes. The objects are selected to have a 60-micron/100-micron ratio similar to Vega, Beta Pic, Alpha PsA, and Epsilon Eri, and they are also required to show evidence of extension in the IRAS Working Survey Database. The fluxes are modeled using a blackbody energy distribution. The temperatures derived range from 50 to 650 K. The diameters of the dust disks observed by IRAS are estimated.
Nearly simultaneous observations of chromospheric and coronal radiative losses of cool stars
NASA Technical Reports Server (NTRS)
Schrijver, C. J.; Dobson, A. K.; Radick, R. R.
1992-01-01
The flux-flux relationships of cool stars are studied on the basis of nearly simultaneous measurements of Ca II H+K, Mg II h+k, and soft X-ray fluxes. A linear relationship is derived between IUE Mg II h+k fluxes and Mount Wilson Ca II H+K fluxes which were obtained within 36 hr of each other for a sample of 26 F5-K3 main-sequence stars. Nearly simultaneous EXOSAT soft X-ray fluxes are compared with Ca II H+K fluxes for a sample of 20 dwarfs and gaints with spectral types ranging from F6 to K2, and 72 additional cool stars for which noncontemporaneous Ca II H+K and EINSTEIN soft X-ray fluxes are available are compared. It is confirmed that a nonradiatively heated chromosphere exists on even the least active main-sequence stars. This basal chromosphere is probably independent of stellar magnetic activity.
Theory of winds in late-type evolved and pre-main-sequence stars
NASA Technical Reports Server (NTRS)
Macgregor, K. B.
1983-01-01
Recent observational results confirm that many of the physical processes which are known to occur in the Sun also occur among late-type stars in general. One such process is the continuous loss of mass from a star in the form of a wind. There now exists an abundance of either direct or circumstantial evidence which suggests that most (if not all) stars in the cool portion of the HR diagram possess winds. An attempt is made to assess the current state of theoretical understanding of mass loss from two distinctly different classes of late-type stars: the post-main-sequence giant/supergiant stars and the pre-main-sequence T Tauri stars. Toward this end, the observationally inferred properties of the wind associated with each of the two stellar classes under consideration are summarized and compared against the predictions of existing theoretical models. Although considerable progress has been made in attempting to identify the mechanisms responsible for mass loss from cool stars, many fundamental problems remain to be solved.
Microstructural Indicators Of Convection In Sills And Dykes
NASA Astrophysics Data System (ADS)
Holness, M. B.; Neufeld, J. A.; Gilbert, A. J.; Macdonald, R.
2016-12-01
The question of whether or not convection occurs in crustal magma chambers is a vexed one, with some advocating vigorous convection while others argue that convection is weak and short-lived. We argue that microstructural analysis is key to determining whether crystallization took place in solidification fronts or whether crystals grew suspended in a convecting magma before settling. The 168m, composite, Shiant Isles Main Sill is dominated by a 140m unit, of which the lower 45m contains olivine phenocrysts. The phenocrysts first fine upwards, then coarsen upwards. The coarsening-upwards sequence contains clustered olivines. Both the extent of sintering and average cluster size increase upwards. The coarsening-upwards sequence is mirrored at the roof. The fining-upwards sequence formed by rapid settling of incoming cargo crystals, while the coarsening-upwards sequence represents post-emplacement growth and clustering of grains suspended in a convecting magma. Convection is also recorded by plagioclase grain shape. Well-facetted and compact plagioclase grains are platy in rapidly-cooled rocks and blocky in slowly-cooled rocks. Plagioclase grain shape varies smoothly across mafic sills, consistent with growth in solidification fronts. In contrast, grain shape is invariant across mafic dykes, consistent with growth as individual grains and clusters suspended in a convecting magma. Convection in sills occurs when the critical Rayleigh number is exceeded, but cooling at vertical walls always results in convective instabilities. That the Shiant Isles Main Sill records prolonged and vigorous convection, while other sills of comparable thickness record grain growth predominantly in solidification fronts, is most likely due to the composite nature of the Shiant. The 140m unit is underlain by 23m of picrite which intruded shortly before - the strongly asymmetric cooling and absence of a cold, stagnant basal thermal boundary layer make convection throughout the sill more likely.
The population of single and binary white dwarfs of the Galactic bulge
NASA Astrophysics Data System (ADS)
Torres, S.; García-Berro, E.; Cojocaru, R.; Calamida, A.
2018-05-01
Recent Hubble Space Telescope observations have unveiled the white dwarf cooling sequence of the Galactic bulge. Although the degenerate sequence can be well fitted employing the most up-to-date theoretical cooling sequences, observations show a systematic excess of red objects that cannot be explained by the theoretical models of single carbon-oxygen white dwarfs of the appropriate masses. Here, we present a population synthesis study of the white dwarf cooling sequence of the Galactic bulge that takes into account the populations of both single white dwarfs and binary systems containing at least one white dwarf. These calculations incorporate state-of-the-art cooling sequences for white dwarfs with hydrogen-rich and hydrogen-deficient atmospheres, for both white dwarfs with carbon-oxygen and helium cores, and also take into account detailed prescriptions of the evolutionary history of binary systems. Our Monte Carlo simulator also incorporates all the known observational biases. This allows us to model with a high degree of realism the white dwarf population of the Galactic bulge. We find that the observed excess of red stars can be partially attributed to white dwarf plus main sequence binaries, and to cataclysmic variables or dwarf novae. Our best fit is obtained with a higher binary fraction and an initial mass function slope steeper than standard values, as well as with the inclusion of differential reddening and blending. Our results also show that the possible contribution of double degenerate systems or young and thick-discbulge stars is negligible.
NASA Astrophysics Data System (ADS)
Olree, E.; Robinson, D. M.; McQuarrie, N.; Ghoshal, S.; Olsen, J.
2016-12-01
Using balanced cross sections, one can visualize a valid and admissible interpretation of the surface and subsurface data. Khanal (2014) and Cross (2014) produced two valid and admissible cross sections along the Marsyandi River in central Nepal. However, thermochronologic data adds another dimension that must be adhered to when producing valid and admissible balanced cross sections. Since the previous cross sections were produced, additional zircon-helium (ZHe) cooling ages along the Marsyandi River show ages of 1 Ma near the Main Central thrust in the hinterland to 4 Ma near the Main Boundary thrust closer to the foreland. This distribution of cooling ages requires recent uplift in the hinterland, which is not present in the cross sections. Although a restored version of the Khanal (2014) cross section is sequentially deformed using 2D Move, the kinematic sequence implied in the cross section is inconsistent with the ZHe age distribution. The hinterland dipping duplex proposed by Khanal would require cooling ages that are oldest near the Main Central thrust and young southwards toward the active ramp located 80 km north of the Main Frontal thrust. Instead, the 4 Ma age near the Main Boundary thrust and the increasingly younger ages to the north could be produced by either a foreland-dipping Lesser Himalayan duplex, which would keep active uplift in the north, or by translation of the hinterland dipping duplex southward over the ramp, moving the active thrust ramp northward. To address this problem, a new balanced cross section was produced using both new mapping through the region and the ZHe age distribution as additional constraints. The section was then restored and sequentially deformed in 2D Move. This study illustrates that multiple cross sections can be viable and admissible; however, they can still be incorrect. Thermochronology places additional constraints on the permissible geometries, and thus increases our ability to predict subsurface geometries. The next step of this project is to link the uplift and erosion implied by the kinematic sequence of the new cross section to the measured cooling history by importing the cross section kinematics into advection diffusion modeling software that predicts cooling ages.
A possible brown dwarf companion to Gliese 569
NASA Technical Reports Server (NTRS)
Forrest, W. J.; Shure, Mark; Skrutskie, M. F.
1988-01-01
A faint cool companion to Gliese 569, discovered during an IR imaging survey of nearby stars, may be the lowest-mass stellar object yet found. The companion is somewhat cooler in its 1.65-3.75-micron energy distribution than the coolest known main-sequence stars, indicating a low mass. Despite its lower temperature, it is more luminous than similar extremely low-mass stars, suggesting that it is either a young low-mass star evolving toward the main sequence or a cooling substellar brown dwarf. The primary star has emission lines and a low space velocity and exhibits flaring, all of which imply youth for this system. Observations of Gliese 569 and its companion over a period of 2 yr confirm the common proper motion expected of a true binary. The 5-arcsec apparent separation (50 AU) implies an orbital period of roughly 500 yr, which will permit an eventual direct determination of the mass of the companion.
Lithium in lower-main-sequence stars of the Alpha Persei cluster
NASA Technical Reports Server (NTRS)
Balachandran, Suchitra; Lambert, David L.; Stauffer, John R.
1988-01-01
Lithium abundances are presented for main-sequence stars of spectral types F, G, and K in the young open cluster Alpha Per. For 46 cluster members, a correlation between Li abundance and projected rotational velocity v sin i is found: all of the Li-poor stars are slow rotators. Two explanations are proposed to account for the correlation: (1) that the Li depletion is introduced following a rapid spin-down phase experienced by young low-mass stars, and that this episode of Li depletion may be the dominant one determining the spread of Li abundances among young low-mass main-sequence stars, and (2) that star formation has occurred over a finite period such that the older stars have undergone a spin-down and depletion of Li by a means that may or may not depend on rotation. The Li abundance in the warm and rapidly rotating stars appears to be undepleted, as is predicted by recent models of pre-main-sequence stars. The depletion observed in the cool stars exceeds the level predicted by these models.
NASA Technical Reports Server (NTRS)
Hobbs, L. M.; Pilachowski, Catherine
1986-01-01
Echelle spectra recorded at the Li I 6707-A line are reported for seven main-sequence members and one cool subgiant in M67. The spectral types of the seven dwarfs studied range from about F8 at the turnoff point to about G5. The principal result is that the average lithium abundance in the three hottest main-sequence stars is 0.45 x 10 to the -9th. Any enrichment of lithium in the gas of the Galactic disk in the last 5 Gyr therefore has not exceeded a factor of about two and probably is entirely negligible, when the corresponding results for NGC 752 and the Hyades are taken into account.
USDA-ARS?s Scientific Manuscript database
Sclerotinia sclerotiorum and S. trifoliorum cause Sclerotinia stem and crown rot of chickpea and white mold on many economically important crops. The host range of S. trifoliorum is mainly on cool season forage and grain legumes of about 40 plant species, whereas the host range of S. sclerotiorum ...
Searching for Partners of Cool Senior Citizens
NASA Astrophysics Data System (ADS)
Jao, Wei-Chun; Henry, T. J.
2012-01-01
Mass is one of the most fundamental parameters in stellar astronomy. In order to measure dynamical masses, one needs to find nearby binary systems that can be resolved and monitored, ideally with orbital periods that completely wrap in a reasonable amount of time. Many surveys have been made of nearby main sequence dwarfs, and their mass-luminosity relation is well established. As part of our Cool Subdwarf Investigations (CSI) program, we are searching for subdwarf binaries of spectral types K and M within 60 parsecs to measure their multiplicity rate and to reveal binaries appropriate for mass determinations. Here we present results of our CSI work using HST's Fine Guidance Sensors. When combined with previous CSI work and results in the literature, we find the multiplicity rate of subdwarfs, 21%, to be surprisingly low compared to that of similar main sequence K and M stars, 37%. This work has several implications, including that the star formation and/or evolution history of subdwarfs is different than for dwarfs, and that ideal systems for subdwarf mass determinations are difficult to find. This work is supported by HST grant GO-11943.
Phase-difference and spectroscopic imaging for monitoring of human brain temperature during cooling.
Weis, Jan; Covaciu, Lucian; Rubertsson, Sten; Allers, Mats; Lunderquist, Anders; Ortiz-Nieto, Francisco; Ahlström, Håkan
2012-12-01
Decrease of the human brain temperature was induced by intranasal cooling. The main purpose of this study was to compare the two magnetic resonance methods for monitoring brain temperature changes during cooling: phase-difference and magnetic resonance spectroscopic imaging (MRSI) with high spatial resolution. Ten healthy volunteers were measured. Selective brain cooling was performed through nasal cavities using saline-cooled balloon catheters. MRSI was based on a radiofrequency spoiled gradient echo sequence. The spectral information was encoded by incrementing the echo time of the subsequent eight image records. Reconstructed voxel size was 1×1×5 mm(3). Relative brain temperature was computed from the positions of water spectral lines. Phase maps were obtained from the first image record of the MRSI sequence. Mild hypothermia was achieved in 15-20 min. Mean brain temperature reduction varied in the interval <-3.0; -0.6>°C and <-2.7; -0.7>°C as measured by the MRSI and phase-difference methods, respectively. Very good correlation was found in all locations between the temperatures measured by both techniques except in the frontal lobe. Measurements in the transversal slices were more robust to the movement artifacts than those in the sagittal planes. Good agreement was found between the MRSI and phase-difference techniques. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramirez, Ramses M.; Kaltenegger, Lisa
We calculate the pre-main-sequence habitable zone (HZ) for stars of spectral classes F-M. The spatial distribution of liquid water and its change during the pre-main-sequence phase of protoplanetary systems is important for understanding how planets become habitable. Such worlds are interesting targets for future missions because the coolest stars could provide habitable conditions for up to 2.5 billion years post-accretion. Moreover, for a given star type, planetary systems are more easily resolved because of higher pre-main-sequence stellar luminosities, resulting in larger planet-star separation for cool stars than is the case for the traditional main-sequence (MS) HZ. We use one-dimensional radiative-convectivemore » climate and stellar evolutionary models to calculate pre-main-sequence HZ distances for F1-M8 stellar types. We also show that accreting planets that are later located in the traditional MS HZ orbiting stars cooler than a K5 (including the full range of M stars) receive stellar fluxes that exceed the runaway greenhouse threshold, and thus may lose substantial amounts of water initially delivered to them. We predict that M-star planets need to initially accrete more water than Earth did, or, alternatively, have additional water delivered later during the long pre-MS phase to remain habitable. Our findings are also consistent with recent claims that Venus lost its water during accretion.« less
Debris Disks Among the Shell Stars: Insights from Spitzer
NASA Technical Reports Server (NTRS)
Roberge, Aki; Weinberger, Alycia; Teske, Johanna
2008-01-01
Shell stars are a class of early-type stars that show narrow absorption lines in their spectra that appear to arise from circumstellar class. This observationally defined class contains a variety of objects, including evolved stars and classical Be stars. However, some of the main sequence shell stars harbor debris disks and younger protoplanetary disks, though this aspect of the class has been largely overlooked. We surveyed a set of main sequence stars for cool dust using Spitzer MIPS and found four additional systems with IR excesses at both 24 and 70 microns. This indicates that the stars have both circumstellar gas and dust, and are likely to be edge-on debris disks. Our estimate of the disk fraction among nearby main sequence shell stars is 48% +/- 14%. We discuss here the nature of the shell stars and present preliminary results from ground-based optical spectra of the survey target stars. We will also outline our planned studies aimed at further characterization of the shell star class.
Multiplicity of the Galactic Senior Citizens: A high-resolution search for cool subdwarf companions
NASA Astrophysics Data System (ADS)
Ziegler, Carl; Law, Nicholas M.
2015-01-01
Cool subdwarfs, with spectral types late K and M, are the oldest members of the low-mass stellar population. Mostly present in the galactic halo, subdwarfs are characterized by their low metallicity and high proper-motions. Understanding their binary fraction could give key insights into the star formation process early in the Milky Way's history. However, because of their low luminosity and relative rarity in the solar neighborhood, binary surveys of cool subdwarfs have suffered from small sample sizes and large incompleteness gaps. It appears, however, that the binary fraction of red subdwarfs is much lower than for their main-sequence cousins. Using the highly efficient Robo-AO system, we present the largest high-resolution survey of subdwarfs yet. We find from 349 target cool subdwarfs, 39 are in multiple systems, 13 newly discovered, for a binary fraction of 11 ± 1.8%.
NASA Astrophysics Data System (ADS)
Jao, Wei-Chun; Henry, Todd J.; Winters, Jennifer G.; Subasavage, John P.; Riedel, Adric R.; Silverstein, Michele L.; Ianna, Philip A.
2017-11-01
Parallaxes, proper motions, and optical photometry are presented for 51 systems consisting of 37 cool subdwarf and 14 additional high proper motion systems. Thirty-seven systems have parallaxes reported for the first time, 15 of which have proper motions of at least 1″ yr‑1. The sample includes 22 newly identified cool subdwarfs within 100 pc, of which three are within 25 pc, and an additional five subdwarfs from 100 to 160 pc. Two systems—LSR 1610-0040 AB and LHS 440 AB—are close binaries exhibiting clear astrometric perturbations that will ultimately provide important masses for cool subdwarfs. We use the accurate parallaxes and proper motions provided here, combined with additional data from our program and others, to determine that effectively all nearby stars with tangential velocities greater than 200 km s‑1 are subdwarfs. We compare a sample of 167 confirmed cool subdwarfs to nearby main sequence dwarfs and Pleiades members on an observational Hertzsprung–Russell diagram using M V versus (V ‑ K s ) to map trends of age and metallicity. We find that subdwarfs are clearly separated for spectral types K5–M5, indicating that the low metallicities of subdwarfs set them apart in the H–R diagram for (V ‑ K s ) = 3–6. We then apply the tangential velocity cutoff and the subdwarf region of the H–R diagram to stars with parallaxes from Gaia Data Release 1 and the MEarth Project to identify a total of 29 new nearby subdwarf candidates that fall clearly below the main sequence.
Comparing the white dwarf cooling sequences in 47 Tuc and NGC 6397
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richer, Harvey B.; Goldsbury, Ryan; Heyl, Jeremy
2013-12-01
Using deep Hubble Space Telescope imaging, color-magnitude diagrams are constructed for the globular clusters 47 Tuc and NGC 6397. As expected, because of its lower metal abundance, the main sequence of NGC 6397 lies well to the blue of that of 47 Tuc. A comparison of the white dwarf cooling sequences of the two clusters, however, demonstrates that these sequences are indistinguishable over most of their loci—a consequence of the settling out of heavy elements in the dense white dwarf atmosphere and the near equality of their masses. Lower quality data on M4 continues this trend to a third clustermore » whose metallicity is intermediate between these two. While the path of the white dwarfs in the color-magnitude diagram is nearly identical in 47 Tuc and NGC 6397, the numbers of white dwarfs along the path are not. This results from the relatively rapid relaxation in NGC 6397 compared to 47 Tuc and provides a cautionary note that simply counting objects in star clusters in random locations as a method of testing stellar evolutionary theory is likely dangerous unless dynamical considerations are included.« less
NASA Technical Reports Server (NTRS)
Melcher, J. C.; Morehead, Robert L.
2014-01-01
The Project Morpheus liquid oxygen (LOX) / liquid methane rocket engines demonstrated acousticcoupled combustion instabilities during sea-level ground-based testing at the NASA Johnson Space Center (JSC) and Stennis Space Center (SSC). High-amplitude, 1T, 1R, 1T1R (and higher order) modes appear to be triggered by injector conditions. The instability occurred during the Morpheus-specific engine ignition/start sequence, and did demonstrate the capability to propagate into mainstage. However, the instability was never observed to initiate during mainstage, even at low power levels. The Morpheus main engine is a JSC-designed 5,000 lbf-thrust, 4:1 throttling, pressure-fed cryogenic engine using an impinging element injector design. Two different engine designs, named HD4 and HD5, and two different builds of the HD4 engine all demonstrated similar instability characteristics. Through the analysis of more than 200 hot fire tests on the Morpheus vehicle and SSC test stand, a relationship between ignition stability and injector/chamber pressure was developed. The instability has the distinct characteristic of initiating at high relative injection pressure drop (dP) at low chamber pressure (Pc); i.e., instabilities initiated at high dP/Pc at low Pc during the start sequence. The high dP/Pc during start results during the injector /chamber chill-in, and is enhanced by hydraulic flip in the injector orifice elements. Because of the fixed mixture ratio of the existing engine design (the main valves share a common actuator), it is not currently possible to determine if LOX or methane injector dP/Pc were individual contributors (i.e., LOX and methane dP/Pc typically trend in the same direction within a given test). The instability demonstrated initiation characteristic of starting at or shortly after methane injector chillin. Colder methane (e.g., sub-cooled) at the injector inlet prior to engine start was much more likely to result in an instability. A secondary effect of LOX sub-cooling was also possibly observed; greater LOX sub- cooling improved stability. Some tests demonstrated a low-amplitude 1L-1T instability prior to LOX injector chill-in. The Morpheus main engine also demonstrated chug instabilities during some engine shutdown sequences on the flight vehicle and SSC test stand. The chug instability was also infrequently observed during the startup sequence. The chug instabilities predictably initiated at low dP/Pc at low Pc. The chug instabilities were always self-limiting; startup chug instabilities terminated during throttle-up and shutdown chug instabilities decayed by shutdown termination.
Detectable close-in planets around white dwarfs through late unpacking
NASA Astrophysics Data System (ADS)
Veras, Dimitri; Gänsicke, Boris T.
2015-02-01
Although 25-50 per cent of white dwarfs (WDs) display evidence for remnant planetary systems, their orbital architectures and overall sizes remain unknown. Vibrant close-in (≃1 R⊙) circumstellar activity is detected at WDs spanning many Gyr in age, suggestive of planets further away. Here we demonstrate how systems with 4 and 10 closely packed planets that remain stable and ordered on the main sequence can become unpacked when the star evolves into a WD and experience pervasive inward planetary incursions throughout WD cooling. Our full-lifetime simulations run for the age of the Universe and adopt main-sequence stellar masses of 1.5, 2.0 and 2.5 M⊙, which correspond to the mass range occupied by the progenitors of typical present-day WDs. These results provide (i) a natural way to generate an ever-changing dynamical architecture in post-main-sequence planetary systems, (ii) an avenue for planets to achieve temporary close-in orbits that are potentially detectable by transit photometry and (iii) a dynamical explanation for how residual asteroids might pollute particularly old WDs.
NASA Astrophysics Data System (ADS)
Ambruster, Carol W.
Most of the cool dwarfs in the interesting age range 10^7-10^8 yr are too faint for IUE, yet such stars are critically important from the viewpoint of stellar evolution. Among stars of this age are the Pleiades K dwarfs, some of which appear to be on the main sequence, and some of which are still arriving there. Up until last year, only 2 stars in this age range had been observed by IUE, both recently: HD 36705 (AB Dor) and HD 17433. Three more stars were identified by the present investigators and observed with IUE during the past (11th) year: HD 129333, a single, nearby solar-type GOV star; HD 82558, a rapidly rotating, single, K2V star; and Ross 137B, the M dwarf common proper motion companion to AB Dor. We have since identified 5 more stars between 10^7 and 10^8 years old that are bright enough to be observed by IUE. They are physically associated, but distant, companions to main sequence O and B stars, identified in the survey of Lindroos (1986). Their ages are thus determined by the short main sequence lifetimes of the hot primaries. Rotational velocities are not yet known for our 5 proposed targets; we will be obtaining these and other data in the coming year. We therefore request time for basic IUE observations of these stars, an LWP-lo, LWP-hi and SWP-lo, for each star. This will ensure that crucial basic fluxes are in the IUE archives, should the satellite die in the coming year. Furthermore these data are immediately useful in filling the gap in the exhaustive study by Simon, Herbig and Boesgaard (1985) of the evolution of TR and chromospheric activity with age. More in-depth coverage will be proposed next year.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Somers, Garrett; Pinsonneault, Marc H., E-mail: somers@astronomy.ohio-state.edu, E-mail: pinsono@astronomy.ohio-state.edu
2014-07-20
We investigate lithium depletion in standard stellar models (SSMs) and main sequence (MS) open clusters, and explore the origin of the Li dispersion in young, cool stars of equal mass, age, and composition. We first demonstrate that SSMs accurately predict the Li abundances of solar analogs at the zero-age main sequence (ZAMS) within theoretical uncertainties. We then measure the rate of MS Li depletion by removing the [Fe/H]-dependent ZAMS Li pattern from three well-studied clusters, and comparing the detrended data. MS depletion is found to be mass-dependent, in the sense of more depletion at low mass. A dispersion in Limore » abundance at fixed T{sub eff} is nearly universal, and sets in by ∼200 Myr. We discuss mass and age dispersion trends, and the pattern is mixed. We argue that metallicity impacts the ZAMS Li pattern, in agreement with theoretical expectations but contrary to the findings of some previous studies, and suggest Li as a test of cluster metallicity. Finally, we argue that a radius dispersion in stars of fixed mass and age, during the epoch of pre-MS Li destruction, is responsible for the spread in Li abundances and the correlation between rotation and Li in young cool stars, most well known in the Pleiades. We calculate stellar models, inflated to match observed radius anomalies in magnetically active systems, and the resulting range of Li abundances reproduces the observed patterns of young clusters. We discuss ramifications for pre-MS evolutionary tracks and age measurements of young clusters, and suggest an observational test.« less
Chromospherically Active Stars in the RAVE Survey. II. Young Dwarfs in the Solar Neighborhood
NASA Astrophysics Data System (ADS)
Žerjal, M.; Zwitter, T.; Matijevič, G.; Grebel, E. K.; Kordopatis, G.; Munari, U.; Seabroke, G.; Steinmetz, M.; Wojno, J.; Bienaymé, O.; Bland-Hawthorn, J.; Conrad, C.; Freeman, K. C.; Gibson, B. K.; Gilmore, G.; Kunder, A.; Navarro, J.; Parker, Q. A.; Reid, W.; Siviero, A.; Watson, F. G.; Wyse, R. F. G.
2017-01-01
A large sample of over 38,000 chromospherically active candidate solar-like stars and cooler dwarfs from the RAVE survey is addressed in this paper. An improved activity identification with respect to the previous study was introduced to build a catalog of field stars in the solar neighborhood with an excess emission flux in the calcium infrared triplet wavelength region. The central result of this work is the calibration of the age-activity relation for main-sequence dwarfs in a range from a few 10 {Myr} up to a few Gyr. It enabled an order of magnitude age estimation of the entire active sample. Almost 15,000 stars are shown to be younger than 1 {Gyr} and ˜2000 younger than 100 {Myr}. The young age of the most active stars is confirmed by their position off the main sequence in the J - K versus {N}{UV}-V diagram showing strong ultraviolet excess, mid-infrared excess in the J - K versus {W}1-{W}2 diagram, and very cool temperatures (J-K> 0.7). They overlap with the reference pre-main-sequence RAVE stars often displaying X-ray emission. The activity level increasing with the color reveals their different nature from the solar-like stars and probably represents an underlying dynamo-generating magnetic fields in cool stars. Of the RAVE objects from DR5, 50% are found in the TGAS catalog and supplemented with accurate parallaxes and proper motions by Gaia. This makes the database of a large number of young stars in a combination with RAVE’s radial velocities directly useful as a tracer of the very recent large-scale star formation history in the solar neighborhood. The data are available online in the Vizier database.
NASA Astrophysics Data System (ADS)
Dieterich, Sergio; Henry, Todd; Jao, W.-C.; Washington, Robert; Silverstein, Michele; Winters, J.; RECONS
2018-01-01
We present a detailed comparison of atmospheric model predictions and photometric observations for late M and L dwarfs. We discuss which wavelength regions are best for determining the fundamental properties of these cool stellar and substellar atmospheres and use this analysis to refine the HR diagram for the hydrogen burning limit first presented in 2014. We also add several new objects to the HR diagram and find little qualitative difference in the HR diagram's overall morphology when compared to our 2014 results. The L2 dwarf 2MASS 0523-1403 remains the smallest hydrogen burning star for which we calculated a radius, thus likely indicating the end of the stellar main sequence. This work is supported by the NSF Astronomy and Astrophysics Postdoctoral Fellowship program through grant AST-1400680.
THE DISCOVERY OF SOLAR-LIKE ACTIVITY CYCLES BEYOND THE END OF THE MAIN SEQUENCE?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Route, Matthew, E-mail: mroute@purdue.edu
2016-10-20
The long-term magnetic behavior of objects near the cooler end of the stellar main sequence is poorly understood. Most theoretical work on the generation of magnetism in these ultracool dwarfs (spectral type ≥M7 stars and brown dwarfs) suggests that their magnetic fields should not change in strength and direction. Using polarized radio emission measurements of their magnetic field orientations, I demonstrate that these cool, low-mass, fully convective objects appear to undergo magnetic polarity reversals analogous to those that occur on the Sun. This powerful new technique potentially indicates that the patterns of magnetic activity displayed by the Sun continue tomore » exist, despite the fully convective interiors of these objects, in contravention of several leading theories of the generation of magnetic fields by internal dynamos.« less
Liang, George
2010-10-26
A blade is provided for a gas turbine. The blade comprises a main body comprising a cooling fluid entrance channel; a cooling fluid collector in communication with the cooling fluid entrance channel; a plurality of side channels extending through an outer wall of the main body and communicating with the cooling fluid collector and a cooling fluid cavity; a cooling fluid exit channel communicating with the cooling fluid cavity; and a plurality of exit bores extending from the cooling fluid exit channel through the main body outer wall.
Some aspects of cool main sequence star ages derived from stellar rotation (gyrochronology)
NASA Astrophysics Data System (ADS)
Barnes, S. A.; Spada, F.; Weingrill, J.
2016-09-01
Rotation periods for cool stars can be measured with good precision by monitoring starspot light modulation. Observations have shown that the rotation periods of dwarf stars of roughly solar metallicity have such systematic dependencies on stellar age and mass that they can be used to derive reliable ages, a procedure called gyrochronology. We review the method and show illustrative cases, including recent ground- and space-based data. The age uncertainties approach 10 % in the best cases, making them a valuable complement to, and constraint on, asteroseismic or other ages. Edited, updated, and refereed version of a presentation at the WE-Heraeus-Seminar in Bad Honnef, Germany: Reconstructing the Milky Way's History: Spectroscopic Surveys, Asteroseismology and Chemodynamical Models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnes, Sydney A.; Weingrill, Joerg; Fritzewski, Dario
We report rotation periods for 20 cool (FGK) main sequence member stars of the 4 Gyr-old open cluster M67 (=NGC 2682), obtained by analyzing data from Campaign 5 of the K2 mission with the Kepler Space Telescope . The rotation periods delineate a sequence in the color–period diagram (CPD) of increasing period with redder color. This sequence represents a cross-section at the cluster age of the surface P = P ( t , M ), suggested in prior work to extend to at least solar age. The current Sun is located marginally (approximately 1 σ ) above M67 in themore » CPD, as its relative age leads us to expect, and lies on the P = P ( t , M ) surface to within measurement precision. We therefore conclude that the solar rotation rate is normal as compared with cluster stars, a fact that strengthens the solar–stellar connection. The agreement between the M67 rotation period measurements and prior predictions further implies that rotation periods, especially when coupled with appropriate supporting work such as spectroscopy, can provide reliable ages via gyrochronology for other similar FGK dwarfs from the early main sequence to solar age and likely until the main sequence turnoff. The M67 rotators have a rotational age of 4.2 Gyr with a standard deviation of 0.7 Gyr, implying that similar field stars can be age-dated to precisions of ∼17%. The rotational age of the M67 cluster as a whole is therefore 4.2 Gyr, but with a lower (averaged) uncertainty of 0.2 Gyr.« less
The coolest extremely low-mass white dwarfs
NASA Astrophysics Data System (ADS)
Calcaferro, Leila M.; Althaus, Leandro G.; Córsico, Alejandro H.
2018-06-01
Context. Extremely low-mass white dwarf (ELM WD; M⋆ ≲ 0.18-0.20 M⊙) stars are thought to be formed in binary systems via stable or unstable mass transfer. Although stable mass transfer predicts the formation of ELM WDs with thick hydrogen (H) envelopes that are characterized by dominant residual nuclear burning along the cooling branch, the formation of ELM WDs with thinner H envelopes from unstable mass loss cannot be discarded. Aims: We compute new evolutionary sequences for helium (He) core WD stars with thin H envelopes with the main aim of assessing the lowest Teff that could be reached by this type of stars. Methods: We generate a new grid of evolutionary sequences of He-core WD stars with thin H envelopes in the mass range from 0.1554 to 0.2025 M⊙, and assess the changes in both the cooling times and surface gravity induced by a reduction of the H envelope. We also determine, taking into account the predictions of progenitor evolution, the lowest Teff reached by the resulting ELM WDs. Results: We find that a slight reduction in the H envelope yields a significant increase in the cooling rate of ELM WDs. Because of this, ELM WDs with thin H envelopes could cool down to 2500 K, in contrast to their canonical counterparts that cool down to 7000 K. In addition, we find that a reduction of the thickness of the H envelope markedly increases the surface gravity (g) of these stars. Conclusions: If ELM WDs are formed with thin H envelopes, they could be detected at very low Teff. The detection of such cool ELM WDs would be indicative that they were formed with thin H envelopes, thus opening the possibility of placing constraints on the possible mechanisms of formation of this type of star. Last but not least, the increase in g due to the reduction of the H envelope leads to consequences in the spectroscopic determinations of these stars.
NASA Technical Reports Server (NTRS)
Linsky, J. L.
1986-01-01
Major advances in our understanding of non-radiative heating and other activity in stars cooler than T sub eff = 10,000K has occured in the last few years. This observational evidence is reviewed and the trends that are now becoming apparent are discussed. The evidence for non-radiatively heated outer atmospheric layers (chromospheres, transition regions, and coronae) in dwarf stars cooler than spectral type A7, in F and G giants, pre-main sequence stars, and close bindary systems is unambiguous, as is the evidence for chromospheres in the K and M giants and supergiants. The existence of non-radiative heating in the outer layers of the A stars remains undetermined despite repeated searches at all wavelengths. Two important trends in the data are the decrease in plasma emission measure with age on the main sequence and decreasing rotational velocity. Variability and atmospheric inhomogeneity are commonly seen, and there is considerable evidence that magnetic fields define the geometry and control the energy balance in the outer atmospheric layers. In addition, the microwave observations imply that non-thermal electrons are confined in coronal magnetic flux tubes in at least the cool dwarfs and RS CVn systems. The chromospheres in the K and M giants and supergiants are geometrically extended, as are the coronae in the RS CVn systems and probably also in other stars.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finley, Adam J.; Matt, Sean P., E-mail: af472@exeter.ac.uk
Cool stars with outer convective envelopes are observed to have magnetic fields with a variety of geometries, which on large scales are dominated by a combination of the lowest-order fields such as the dipole, quadrupole, and octupole modes. Magnetized stellar wind outflows are primarily responsible for the loss of angular momentum from these objects during the main sequence. Previous works have shown the reduced effectiveness of the stellar wind braking mechanism with increasingly complex but singular magnetic field geometries. In this paper, we quantify the impact of mixed dipolar and quadrupolar fields on the spin-down torque using 50 MHD simulationsmore » with mixed fields, along with 10 each of the pure geometries. The simulated winds include a wide range of magnetic field strength and reside in the slow-rotator regime. We find that the stellar wind braking torque from our combined geometry cases is well described by a broken power-law behavior, where the torque scaling with field strength can be predicted by the dipole component alone or the quadrupolar scaling utilizing the total field strength. The simulation results can be scaled and apply to all main-sequence cool stars. For solar parameters, the lowest-order component of the field (dipole in this paper) is the most significant in determining the angular momentum loss.« less
Momentum and energy balance in late-type stellar winds
NASA Technical Reports Server (NTRS)
Macgregor, K. B.
1981-01-01
Observations at ultraviolet and X-ray wavelengths indicate that the classical picture of a static stellar atmosphere containing a radiative equilibrium temperature distribution is inapplicable to the majority of late type stars. Mass loss and the presence of atmospheric regions characterized by gas temperatures in excess of the stellar effective temperature appear to be almost ubiquitous throughout the HR diagram. Evidence pertaining to the thermal and dynamical structure of the outer envelopes of cool stars is summarized. These results are compared with the predictions of several theoretical models which were proposed to account for mass loss from latetype stars. Models in which the outflow is thermally radiatively, or wave driven are considered for identification of the physical processes responsible for the observed wind properties. The observed variation of both the wind, thermal and dynamical structure as one proceeds from the supergiant branch toward the main sequence in the cool portion of the HR diagram give consideration to potential mechanisms for heating and cooling the flow from low gravity stars.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cadelano, M.; Pallanca, C.; Ferraro, F. R.
2015-10-10
We used ultra-deep UV observations obtained with the Hubble Space Telescope to search for optical companions to binary millisecond pulsars (MSPs) in the globular cluster 47 Tucanae. We identified four new counterparts (to MSPs 47TucQ, 47TucS, 47TucT, and 47TucY) and confirmed those already known (to MSPs 47TucU and 47TucW). In the color–magnitude diagram, the detected companions are located in a region between the main sequence and the CO white dwarf (WD) cooling sequences, consistent with the cooling tracks of He WDs with masses between 0.15 M{sub ⊙} and 0.20 M{sub ⊙}. For each identified companion, mass, cooling age, temperature, andmore » pulsar mass (as a function of the inclination angle) have been derived and discussed. For 47TucU we also found that the past accretion history likely proceeded at a sub-Eddington rate. The companion to the redback 47TucW is confirmed to be a non-degenerate star, with properties particularly similar to those observed for black widow systems. Two stars have been identified within the 2σ astrometric uncertainty from the radio positions of 47TucH and 47TucI, but the available data prevent us from firmly assessing whether they are the true companions of these two MSPs.« less
First detection of the white dwarf cooling sequence of the galactic bulge
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calamida, A.; Sahu, K. C.; Anderson, J.
2014-08-01
We present Hubble Space Telescope data of the low-reddening Sagittarius window in the Galactic bulge. The Sagittarius Window Eclipsing Extrasolar Planet Search field (∼3'× 3'), together with three more Advanced Camera for Surveys and eight Wide-Field Camera 3 fields, were observed in the F606W and F814W filters, approximately every two weeks for 2 yr, with the principal aim of detecting a hidden population of isolated black holes and neutron stars through astrometric microlensing. Proper motions were measured with an accuracy of ≈0.1 mas yr{sup –1} (≈4 km s{sup –1}) at F606W ≈ 25.5 mag, and better than ≈0.5 mas yr{supmore » –1} (≈20 km s{sup –1}) at F606W ≈ 28 mag, in both axes. Proper-motion measurements allowed us to separate disk and bulge stars and obtain a clean bulge color-magnitude diagram. We then identified for the first time a white dwarf (WD) cooling sequence in the Galactic bulge, together with a dozen candidate extreme horizontal branch stars. The comparison between theory and observations shows that a substantial fraction of the WDs (≈30%) are systematically redder than the cooling tracks for CO-core H-rich and He-rich envelope WDs. This evidence would suggest the presence of a significant number of low-mass WDs and WD-main-sequence binaries in the bulge. This hypothesis is further supported by the finding of two dwarf novae in outburst, two short-period (P ≲ 1 day) ellipsoidal variables, and a few candidate cataclysmic variables in the same field.« less
Farhat, Maha; Shaheed, Raja A; Al-Ali, Haider H; Al-Ghamdi, Abdullah S; Al-Hamaqi, Ghadeer M; Maan, Hawraa S; Al-Mahfoodh, Zainab A; Al-Seba, Hussain Z
2018-02-01
To investigate the presence of Legionella spp in cooling tower water. Legionella proliferation in cooling tower water has serious public health implications as it can be transmitted to humans via aerosols and cause Legionnaires' disease. Samples of cooling tower water were collected from King Fahd Hospital of the University (KFHU) (Imam Abdulrahman Bin Faisal University, 2015/2016). The water samples were analyzed by a standard Legionella culture method, real-time polymerase chain reaction (RT-PCR), and 16S rRNA next-generation sequencing. In addition, the bacterial community composition was evaluated. All samples were negative by conventional Legionella culture. In contrast, all water samples yielded positive results by real-time PCR (105 to 106 GU/L). The results of 16S rRNA next generation sequencing showed high similarity and reproducibility among the water samples. The majority of sequences were Alpha-, Beta-, and Gamma-proteobacteria, and Legionella was the predominant genus. The hydrogen-oxidizing gram-negative bacterium Hydrogenophaga was present at high abundance, indicating high metabolic activity. Sphingopyxis, which is known for its resistance to antimicrobials and as a pioneer in biofilm formation, was also detected. Our findings indicate that monitoring of Legionella in cooling tower water would be enhanced by use of both conventional culturing and molecular methods.
X-ray Emission from Pre-Main-Sequence Stars - Testing the Solar Analogy
NASA Technical Reports Server (NTRS)
Skinner, Stephen L.
2000-01-01
This LTSA award funded my research on the origin of stellar X-ray emission and the validity of the solar-stellar analogy. This research broadly addresses the relevance of our current understanding of solar X-ray physics to the interpretation of X-ray emission from stars in general. During the past five years the emphasis has been on space-based X-ray observations of very young stars in star-forming regions (T Tauri stars and protostars), cool solar-like G stars, and evolved high-mass Wolf-Rayet (WR) stars. These observations were carried out primarily with the ASCA and ROSAT space-based observatories (and most recently with Chandra), supplemented by ground-based observations. This research has focused on the identification of physical processes that are responsible for the high levels of X-ray emission seen in pre-main-sequence (PMS) stars, active cool stars, and WR stars. A related issue is how the X-ray emission of such stars changes over time, both on short timescales of days to years and on evolutionary timescales of millions of years. In the case of the Sun it is known that magnetic fields play a key role in the production of X-rays by confining the coronal plasma in loop-like structures where it is heated to temperatures of several million K. The extent to which the magnetically-confined corona interpretation can be applied to other X-ray emitting stars is the key issue that drives the research summarized here.
Stellar Magnetism, Winds and their Effects on Planetary Environments
NASA Astrophysics Data System (ADS)
Vidotto, A. A.
2016-08-01
Here, I review some recent works on magnetism of cool, main-sequence stars, their winds and potential impact on surrounding exoplanets. The winds of these stars are very tenuous and persist during their lifetime. Although carrying just a small fraction of the stellar mass, these magnetic winds carry away angular momentum, thus regulating the rotation of the star. Since cool stars are likely to be surrounded by planets, understanding the host star winds and magnetism is a key step towards characterisation of exoplanetary environments. As rotation and activity are intimately related, the spin down of stars leads to a decrease in stellar activity with age. As a consequence, as stars age, a decrease in high-energy (X-ray, extreme ultraviolet) irradiation is observed, which can a ect the evaporation of exoplanetary atmospheres and, thus, also altering exoplanetary evolution.
A surprise at the bottom of the main sequence: Rapid rotation and NO H-alpha emission
NASA Technical Reports Server (NTRS)
Basri, Gibor; Marcy, Geoffrey W.
1995-01-01
We report Kech Observatory high-resolution echelle spectra from 640-850 nm for eight stars near the faint end of the main sequence. These spectra are the highest resolution spectra of such late-type stars, and clearly resolve the TiO, VO, and atomic lines. The sample includes the field brown-dwarf candidate, BRI 0021-0214 (M9.5+). Very unexpectedly, it shows the most rapid rotation in the entire samples, v sin i approximately 40 km/s, which is 20x faster than typical field nonemission M stars. Equally surprising is that BRI 0021 exhibits no emission or absorptionat H-alpha. We argue that this absence is not simply due to its cool photosphere, but that stellar activity declines in a fundamental way at the end of the main sequence. As it is the first very late M dwarf observed at high spectral resolution, BRI 0021 may be signaling a qualitative change in the angular momentum loss rate among the lowest mass stars. Conventionally, its rapid rotation would have marked BRI 0021 as very young, consistent with the selection effect which arises if the latest-type dwarfs are really brown dwarfs on cooling curves. In any case, it is unprecedented to find no sign of stellar activity in such a rapidly rotating convective star. We also discuss the possible conflict between this observation and the extremely strong H-alpha seen in another very cool star, PC 0025+0447. Extrapolation of M-L relations for BRI 0021 yields M approximately 0.065 solar mass, and the other sample objects have expected masses near the H-burning limit. These include two Pleiades brown-dwarf candidates, four field M6 dwarfs and one late-type T Tauri star. The two Pleiades M6 dwarfs have v sin i of 26 and 37 km/s, H-alpha in emission, and radial velocities consistent with Pleiades M6 dwarfs have v sin i of 26 and 37 km/s, H-alpha in emission, and radial velocities consistent with Pleiades membership. Similarly, the late-type T Tauri star has v sin i approximately 30 km/s and H alpha emission indicate of its youth. Two of the four late-type field dMe star also exhibit rotation above 5 km/s, consistent with expectations. BRI 0021 has no measurable absoprtion due to lithium, indicating that it is likely to be more massive than 0.065 solar mass.
Air film cooling in a nonadiabatic wall conical nozzle.
NASA Technical Reports Server (NTRS)
Boldman, D. R.; Papell, S. S.; Ehlers, R. C.
1972-01-01
Experimental data for an air-film cooled conical nozzle operating with a heated-air main stream and a water-cooled wall confirm the validity of Lieu's (1964) method for correlating film cooling data in the accelerated flow of a nonadiabatic-wall nozzle. The film cooling effectiveness modified for nonadiabatic walls by Lieu can be used to correlate film cooling under the condition that the main-stream to coolant velocity ratio at the slot is about 1. Such a ratio provides the optimum cooling effectiveness.
Evidence that the X-Ray Plasma in Microflares is in a Sequence of Subresolution Magnetic Tubes
NASA Technical Reports Server (NTRS)
Moore, Ronald L.; Falconer, D. A.; Porter, Jason G.
1998-01-01
We analyze the cooling of the X-ray emitting thermal plasma in microflares observed in active regions by the Yohkoh Soft X-ray Telescope. A typical microflare appears to be a transient brightening of an entire small magnetic loop, often having a diameter near the limit of resolution (approximately 2 x 10(exp 8) cm) (Shimizu 1995, PASJ, 47, 251). The X-ray plasma in the loop cools by emission of XUV radiation and by heat conduction to the cooler plasma at the feet of the loop. The cooling rate is determined by the plasma temperature and density and the loop length. The plasma density is determined from the observed X-ray brightness of the loop in combination with the temperature, the loop diameter, and the filling factor. The filling factor is the volume fraction of the loop occupied by the subset of magnetic tubes that is filled by the X-ray plasma and that contains practically all of the X-ray plasma present in the microflare loop. Taking typical values from the hundreds of microflares measured by Shimizu (1995) (X-ray brightness through the thin aluminum filter approximately 4 x 10(exp 3) DN/s/pixel, lifetime approximately 5 min, temperature approximately 6 x 10(exp 6) K, loop length approximately 10(exp 9) cm, loop diameter approximately 3 x 10(exp 8) cm), we find that for filling factors greater than approximately 1% (1) the cooling time is much shorter than the duration of the microflare, and (2) conductive cooling strongly dominates over radiative cooling. Because the cooling time is so short and because the conductive heat flux goes mainly into increasing the plasma density via chromospheric evaporation, we are compelled to conclude that (1) heating to X-ray temperatures continues through nearly the entire life of a microflare, (2) the heating keeps changing to different field lines, so that any one magnetic tube in the sequence of heated tubes emits X-rays only briefly in the life of the microflare, and (3) at any instant during the microflare the tubes filled with X-ray plasma occupy only a small fraction (less than approximately 10%) of the microflare loop. Hence, we expect that coronal X-ray images with spatial resolution 2-3 times better than from Yohkoh will show plenty of rapidly changing filamentary substructure in microflares.
White dwarf-main sequence binaries from LAMOST: the DR5 catalogue
NASA Astrophysics Data System (ADS)
Ren, J.-J.; Rebassa-Mansergas, A.; Parsons, S. G.; Liu, X.-W.; Luo, A.-L.; Kong, X.; Zhang, H.-T.
2018-07-01
We present the data release (DR) 5 catalogue of white dwarf-main sequence (WDMS) binaries from the Large sky Area Multi-Object fibre Spectroscopic Telescope (LAMOST). The catalogue contains 876 WDMS binaries, of which 757 are additions to our previous LAMOST DR1 sample and 357 are systems that have not been published before. We also describe a LAMOST-dedicated survey that aims at obtaining spectra of photometrically selected WDMS binaries from the Sloan Digital Sky Survey (SDSS) that are expected to contain cool white dwarfs and/or early-type M dwarf companions. This is a population under-represented in previous SDSS WDMS binary catalogues. We determine the stellar parameters (white dwarf effective temperatures, surface gravities and masses, and M dwarf spectral types) of the LAMOST DR5 WDMS binaries and make use of the parameter distributions to analyse the properties of the sample. We find that, despite our efforts, systems containing cool white dwarfs remain under-represented. Moreover, we make use of LAMOST DR5 and SDSS DR14 (when available) spectra to measure the Na I λλ 8183.27, 8194.81 absorption doublet and/or Hα emission radial velocities of our systems. This allows identifying 128 binaries displaying significant radial velocity variations, 76 of which are new. Finally, we cross-match our catalogue with the Catalina Surveys and identify 57 systems displaying light-curve variations. These include 16 eclipsing systems, two of which are new, and nine binaries that are new eclipsing candidates. We calculate periodograms from the photometric data and measure (estimate) the orbital periods of 30 (15) WDMS binaries.
White dwarf-main sequence binaries from LAMOST: the DR5 catalogue
NASA Astrophysics Data System (ADS)
Ren, J.-J.; Rebassa-Mansergas, A.; Parsons, S. G.; Liu, X.-W.; Luo, A.-L.; Kong, X.; Zhang, H.-T.
2018-03-01
We present the data release (DR) 5 catalogue of white dwarf-main sequence (WDMS) binaries from the Large Area Multi-Object fiber Spectroscopic Telescope (LAMOST). The catalogue contains 876 WDMS binaries, of which 757 are additions to our previous LAMOST DR1 sample and 357 are systems that have not been published before. We also describe a LAMOST-dedicated survey that aims at obtaining spectra of photometrically-selected WDMS binaries from the Sloan Digital Sky Survey (SDSS) that are expected to contain cool white dwarfs and/or early type M dwarf companions. This is a population under-represented in previous SDSS WDMS binary catalogues. We determine the stellar parameters (white dwarf effective temperatures, surface gravities and masses, and M dwarf spectral types) of the LAMOST DR5 WDMS binaries and make use of the parameter distributions to analyse the properties of the sample. We find that, despite our efforts, systems containing cool white dwarfs remain under-represented. Moreover, we make use of LAMOST DR5 and SDSS DR14 (when available) spectra to measure the Na I λλ 8183.27, 8194.81 absorption doublet and/or Hα emission radial velocities of our systems. This allows identifying 128 binaries displaying significant radial velocity variations, 76 of which are new. Finally, we cross-match our catalogue with the Catalina Surveys and identify 57 systems displaying light curve variations. These include 16 eclipsing systems, two of which are new, and nine binaries that are new eclipsing candidates. We calculate periodograms from the photometric data and measure (estimate) the orbital periods of 30 (15) WDMS binaries.
Loss of DHR sequences at Browns Ferry Unit One - accident-sequence analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, D.H.; Grene, S.R.; Harrington, R.M.
1983-05-01
This study describes the predicted response of Unit One at the Browns Ferry Nuclear Plant to a postulated loss of decay heat removal (DHR) capability following scram from full power with the power conversion system unavailable. In accident sequences without DHR capability, the residual heat removal (RHR) system functions of pressure suppression pool cooling and reactor vessel shutdown cooling are unavailable. Consequently, all decay heat energy is stored in the pressure suppression pool with a concomitant increase in pool temperature and primary containment pressure. With the assumption that DHR capability is not regained during the lengthy course of this accidentmore » sequence, the containment ultimately fails by overpressurization. Although unlikely, this catastrophic failure might lead to loss of the ability to inject cooling water into the reactor vessel, causing subsequent core uncovery and meltdown. The timing of these events and the effective mitigating actions that might be taken by the operator are discussed in this report.« less
Qin, Tian; Zhou, Haijian; Ren, Hongyu; Guan, Hong; Li, Machao; Zhu, Bingqing; Shao, Zhujun
2014-04-01
Legionella pneumophila serogroup 1 causes Legionnaires' disease. Water systems contaminated with Legionella are the implicated sources of Legionnaires' disease. This study analyzed L. pneumophila serogroup 1 strains in China using sequence-based typing. Strains were isolated from cooling towers (n = 96), hot springs (n = 42), and potable water systems (n = 26). Isolates from cooling towers, hot springs, and potable water systems were divided into 25 sequence types (STs; index of discrimination [IOD], 0.711), 19 STs (IOD, 0.934), and 3 STs (IOD, 0.151), respectively. The genetic variation among the potable water isolates was lower than that among cooling tower and hot spring isolates. ST1 was the predominant type, accounting for 49.4% of analyzed strains (n = 81), followed by ST154. With the exception of two strains, all potable water isolates (92.3%) belonged to ST1. In contrast, 53.1% (51/96) and only 14.3% (6/42) of cooling tower and hot spring, respectively, isolates belonged to ST1. There were differences in the distributions of clone groups among the water sources. The comparisons among L. pneumophila strains isolated in China, Japan, and South Korea revealed that similar clones (ST1 complex and ST154 complex) exist in these countries. In conclusion, in China, STs had several unique allelic profiles, and ST1 was the most prevalent sequence type of environmental L. pneumophila serogroup 1 isolates, similar to its prevalence in Japan and South Korea.
Genome Sequence of Legionella massiliensis, Isolated from a Cooling Tower Water Sample.
Pagnier, Isabelle; Croce, Olivier; Robert, Catherine; Raoult, Didier; La Scola, Bernard
2014-10-16
We present the draft genome sequence of Legionella massiliensis strain LegA(T), recovered from a cooling tower water sample, using an amoebal coculture procedure. The strain described here is composed of 4,387,007 bp, with a G+C content of 41.19%, and its genome has 3,767 protein-coding genes and 60 predicted RNA genes. Copyright © 2014 Pagnier et al.
NASA Technical Reports Server (NTRS)
Moore, Judith G.
1992-01-01
NMSB Movie computer program displays large sets of data (more than million individual values). Presentation dynamic, rapidly displaying sequential image "frames" in main "movie" window. Any sequence of two-dimensional sets of data scaled between 0 and 255 (1-byte resolution) displayed as movie. Time- or slice-wise progression of data illustrated. Originally written to present data from three-dimensional ultrasonic scans of damaged aerospace composite materials, illustrates data acquired by thermal-analysis systems measuring rates of heating and cooling of various materials. Developed on Macintosh IIx computer with 8-bit color display adapter and 8 megabytes of memory using Symantec Corporation's Think C, version 4.0.
Spectroscopy of hot subdwarf binaries
NASA Astrophysics Data System (ADS)
Kreuzer, Simon; Irrgang, Andreas; Heber, Ulrich
2018-06-01
We present a status report of our spectroscopic analysis of subdwarf binaries consisting of a subdwarf and a F/G/K-type main-sequence companion. These systems selected from SDSS photometry show significant excess in the (infra-)red which can not be explained by interstellar reddening. Inspection of SDSS spectra revealed that most of them are composite spectrum sdB binaries. Once their spectra are disentangled, a detailed spectral analysis can be carried out. It reveals Teff, log g and the metal abundance of each individual star. The cool companion is of particular interest, because its spectrum reveals the original chemical composition of the binary.
2008-09-20
surface gravity . With ourL-band spectra in order 25 (3.0450Y3.0865m;Fig. 1e), we detect strong HCN absorption (10% deep) and weaker C2H2 absorption in...Doppmann et al. 2005). The absorption lines of Na i and Mg i are particularly gravity and temperature sensitive, but in the opposite sense from each...other. For example, at cool effective temperatures (3200Y4500 K) and subdwarf surface gravities (3:5 log g 4:5) Na andMg lines both grow stronger as
Time-dependent corona models - Scaling laws
NASA Technical Reports Server (NTRS)
Korevaar, P.; Martens, P. C. H.
1989-01-01
Scaling laws are derived for the one-dimensional time-dependent Euler equations that describe the evolution of a spherically symmetric stellar atmosphere. With these scaling laws the results of the time-dependent calculations by Korevaar (1989) obtained for one star are applicable over the whole Hertzsprung-Russell diagram and even to elliptic galaxies. The scaling is exact for stars with the same M/R-ratio and a good approximation for stars with a different M/R-ratio. The global relaxation oscillation found by Korevaar (1989) is scaled to main sequence stars, a solar coronal hole, cool giants and elliptic galaxies.
Solidification Sequence of Spray-Formed Steels
NASA Astrophysics Data System (ADS)
Zepon, Guilherme; Ellendt, Nils; Uhlenwinkel, Volker; Bolfarini, Claudemiro
2016-02-01
Solidification in spray-forming is still an open discussion in the atomization and deposition area. This paper proposes a solidification model based on the equilibrium solidification path of alloys. The main assumptions of the model are that the deposition zone temperature must be above the alloy's solidus temperature and that the equilibrium liquid fraction at this temperature is reached, which involves partial remelting and/or redissolution of completely solidified droplets. When the deposition zone is cooled, solidification of the remaining liquid takes place under near equilibrium conditions. Scanning electron microscopy (SEM) and optical microscopy (OM) were used to analyze the microstructures of two different spray-formed steel grades: (1) boron modified supermartensitic stainless steel (SMSS) and (2) D2 tool steel. The microstructures were analyzed to determine the sequence of phase formation during solidification. In both cases, the solidification model proposed was validated.
Legionella confirmation in cooling tower water
Farhat, Maha; Shaheed, Raja A.; Al-Ali, Haidar H.; Al-Ghamdi, Abdullah S.; Al-Hamaqi, Ghadeer M.; Maan, Hawraa S.; Al-Mahfoodh, Zainab A.; Al-Seba, Hussain Z.
2018-01-01
Objectives: To investigate the presence of Legionella spp in cooling tower water. Legionella proliferation in cooling tower water has serious public health implications as it can be transmitted to humans via aerosols and cause Legionnaires’ disease. Methods: Samples of cooling tower water were collected from King Fahd Hospital of the University (KFHU) (Imam Abdulrahman Bin Faisal University, 2015/2016). The water samples were analyzed by a standard Legionella culture method, real-time polymerase chain reaction (RT-PCR), and 16S rRNA next-generation sequencing. In addition, the bacterial community composition was evaluated. Results: All samples were negative by conventional Legionella culture. In contrast, all water samples yielded positive results by real-time PCR (105 to 106 GU/L). The results of 16S rRNA next generation sequencing showed high similarity and reproducibility among the water samples. The majority of sequences were Alpha-, Beta-, and Gamma-proteobacteria, and Legionella was the predominant genus. The hydrogen-oxidizing gram-negative bacterium Hydrogenophaga was present at high abundance, indicating high metabolic activity. Sphingopyxis, which is known for its resistance to antimicrobials and as a pioneer in biofilm formation, was also detected. Conclusion: Our findings indicate that monitoring of Legionella in cooling tower water would be enhanced by use of both conventional culturing and molecular methods. PMID:29436561
Evidence of the evolved nature of the B[e] star MWC 137
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muratore, M. F.; Arias, M. L.; Cidale, L.
2015-01-01
The evolutionary phase of B[e] stars is difficult to establish due to the uncertainties in their fundamental parameters. For instance, possible classifications for the Galactic B[e] star MWC 137 include pre-main-sequence and post-main-sequence phases, with a large range in luminosity. Our goal is to clarify the evolutionary stage of this peculiar object, and to study the CO molecular component of its circumstellar medium. To this purpose, we modeled the CO molecular bands using high-resolution K-band spectra. We find that MWC 137 is surrounded by a detached cool (T=1900±100 K) and dense (N=(3±1)×10{sup 21} cm{sup −2}) ring of CO gas orbitingmore » the star with a rotational velocity, projected to the line of sight, of 84 ± 2 km s{sup −1}. We also find that the molecular gas is enriched in the isotope {sup 13}C, excluding the classification of the star as a Herbig Be. The observed isotopic abundance ratio ({sup 12}C/{sup 13}C = 25 ± 2) derived from our modeling is compatible with a proto-planetary nebula, main-sequence, or supergiant evolutionary phase. However, based on some observable characteristics of MWC 137, we propose that the supergiant scenario seems to be the most plausible. Hence, we suggest that MWC 137 could be in an extremely short-lived phase, evolving from a B[e] supergiant to a blue supergiant with a bipolar ring nebula.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huber, D.; Bedding, T. R.; Stello, D.
2011-12-20
We have analyzed solar-like oscillations in {approx}1700 stars observed by the Kepler Mission, spanning from the main sequence to the red clump. Using evolutionary models, we test asteroseismic scaling relations for the frequency of maximum power ({nu}{sub max}), the large frequency separation ({Delta}{nu}), and oscillation amplitudes. We show that the difference of the {Delta}{nu}-{nu}{sub max} relation for unevolved and evolved stars can be explained by different distributions in effective temperature and stellar mass, in agreement with what is expected from scaling relations. For oscillation amplitudes, we show that neither (L/M){sup s} scaling nor the revised scaling relation by Kjeldsen andmore » Bedding is accurate for red-giant stars, and demonstrate that a revised scaling relation with a separate luminosity-mass dependence can be used to calculate amplitudes from the main sequence to red giants to a precision of {approx}25%. The residuals show an offset particularly for unevolved stars, suggesting that an additional physical dependency is necessary to fully reproduce the observed amplitudes. We investigate correlations between amplitudes and stellar activity, and find evidence that the effect of amplitude suppression is most pronounced for subgiant stars. Finally, we test the location of the cool edge of the instability strip in the Hertzsprung-Russell diagram using solar-like oscillations and find the detections in the hottest stars compatible with a domain of hybrid stochastically excited and opacity driven pulsation.« less
Morohoshi, Tomohiro; Sato, Niina; Iizumi, Taro; Tanaka, Airi; Ikeda, Tsukasa
2017-05-01
Biofilm formation by bacteria is one of the main causes of fouling in industrial cooling water systems. In many gram-negative bacteria, biofilm formation is regulated by N-acyl-homoserine lactone (AHL)-mediated quorum sensing. In this study, we isolated three AHL-degrading bacteria from cooling water systems and identified them as Sphingomonas ursincola. The draft genome sequence of S. ursincola A1 revealed the presence of an AHL-degrading gene homolog, designated qsdS. The qsdS region was also amplified by PCR from the genomes of the other two S. ursincola strains, SF1 and SF8. Escherichia coli DH5α harboring a QsdS-expressing plasmid showed high degradative activity against AHLs with short and 3-oxo-substituted acyl chains. High-performance liquid chromatography analysis revealed that QsdS is an AHL lactonase, an enzyme that catalyzes AHL ring opening. Furthermore, heterologous expression of QsdS in Pseudomonas aeruginosa PAO1 resulted in degradation of endogenous AHLs and interfered with the quorum-sensing-regulated phenotype. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Yao, Jianjun; Cao, Hu; Ge, Wenwei; Li, Jiefang; Viehland, D.
2009-08-01
We report the finding of a monoclinic MB phase in Pb(Zn1/3Nb2/3)O3-4.5%PbTiO3 single crystals. High precision x-ray diffraction investigations of [110] field cooled crystals have shown a transformation sequence of cubic(C)→tetragonal(T)→orthorhombic(O)→monoclinic(MB), which is different from that previously reported [A.-E. Renault et al., J. Appl. Phys. 97, 044105 (2005)]. Beginning in the zero-field-cooled condition at 383 K, a rhombohedral (R)→MB→O sequence was observed with increasing field. Coexisting MB and O phases were then found upon removal of field, which fully transformed to MB on cooling to room temperature.
Multiplicity of the Galactic Senior Citizens: A High-resolution Search for Cool Subdwarf Companions
NASA Astrophysics Data System (ADS)
Ziegler, Carl; Law, Nicholas M.; Baranec, Christoph; Riddle, Reed L.; Fuchs, Joshua T.
2015-05-01
Cool subdwarfs are the oldest members of the low-mass stellar population. Mostly present in the galactic halo, subdwarfs are characterized by their low-metallicity. Measuring their binary fraction and comparing it to solar-metallicity stars could give key insights into the star formation process early in the Milky Way’s history. However, because of their low luminosity and relative rarity in the solar neighborhood, binarity surveys of cool subdwarfs have suffered from small sample sizes and incompleteness. Previous surveys have suggested that the binary fraction of red subdwarfs is much lower than for their main-sequence cousins. Using the highly efficient Robo-AO system, we present the largest high-resolution survey of subdwarfs, sensitive to angular separations (ρ ≥slant 0.″ 15) and contrast ratios ({Δ }{{m}i} ≤slant 6) invisible in past surveys. Of 344 target cool subdwarfs, 43 are in multiple systems, 19 of which are newly discovered, for a binary fraction of 12.5 ± 1.9%. We also discovered seven triple star systems for a triplet fraction of 2.0 ± 0.8%. Comparisons to similar surveys of solar-metallicity dwarf stars gives a ∼3σ disparity in luminosity between companion stars, with subdwarfs displaying a shortage of low-contrast companions. We also observe a lack of close subdwarf companions in comparison to similar-mass dwarf multiple systems.
Williams, R.A.; McCallister, N.S.; Dart, R.L.
2011-01-01
This poster summarizes a few of the more significant facts about the series of large earthquakes that struck the New Madrid seismic zone of southeastern Missouri, northeastern Arkansas, and adjacent parts of Tennessee and Kentucky from December 1811 to February 1812. Three earthquakes in this sequence had a magnitude (M) of 7.0 or greater. The first earthquake occurred on December 16, 1811, at 2:15 a.m.; the second on January 23, 1812, at 9 a.m.; and the third on February 7, 1812, at 3:45 a.m. These three earthquakes were among the largest to strike North America since European settlement. The mainshocks were followed by many hundreds of aftershocks that occurred over the next decade. Many of the aftershocks were major earthquakes themselves. The area that was strongly shaken by the three main shocks was 2-3 times as large as the strongly shaken area of the 1964 M9.2 Alaskan earthquake and 10 times as large as that of the 1906 M7.8 San Francisco earthquake. Geologic studies show that the 1811-1812 sequence was not an isolated event in the New Madrid region. The 1811-1812 New Madrid earthquake sequence was preceded by at least two other similar sequences in about A.D. 1450 and A.D. 900. Research also indicates that other large earthquakes have occurred in the region surrounding the main New Madrid seismicity trends in the past 5,000 years or so.
NASA Astrophysics Data System (ADS)
Gilmore, Michelle E.; McQuarrie, Nadine; Eizenhöfer, Paul R.; Ehlers, Todd A.
2018-05-01
In this study, reconstructions of a balanced geologic cross section in the Himalayan fold-thrust belt of eastern Bhutan are used in flexural-kinematic and thermokinematic models to understand the sensitivity of predicted cooling ages to changes in fault kinematics, geometry, topography, and radiogenic heat production. The kinematics for each scenario are created by sequentially deforming the cross section with ˜ 10 km deformation steps while applying flexural loading and erosional unloading at each step to develop a high-resolution evolution of deformation, erosion, and burial over time. By assigning ages to each increment of displacement, we create a suite of modeled scenarios that are input into a 2-D thermokinematic model to predict cooling ages. Comparison of model-predicted cooling ages to published thermochronometer data reveals that cooling ages are most sensitive to (1) the location and size of fault ramps, (2) the variable shortening rates between 68 and 6.4 mm yr-1, and (3) the timing and magnitude of out-of-sequence faulting. The predicted ages are less sensitive to (4) radiogenic heat production and (5) estimates of topographic evolution. We used the observed misfit of predicted to measured cooling ages to revise the cross section geometry and separate one large ramp previously proposed for the modern décollement into two smaller ramps. The revised geometry results in an improved fit to observed ages, particularly young AFT ages (2-6 Ma) located north of the Main Central Thrust. This study presents a successful approach for using thermochronometer data to test the viability of a proposed cross section geometry and kinematics and describes a viable approach to estimating the first-order topographic evolution of a compressional orogen.
Cooling towers--a potential environmental source of slow-growing mycobacterial species.
Black, Walter C; Berk, Sharon G
2003-01-01
Over the last decade a rise in the frequency of disease caused by nontuberculous mycobacteria (NTM) has occurred, especially among AIDS patients. The lack of evidence for person-to-person transmission indicates the environment is a source of infection. The ecology and environmental sources of NTMs are poorly understood, and many pathogenic strains have not been observed outside of clinical cases. Several species of NTMs have been reported from treated water distribution systems; however, one type of manmade environment that has not been examined for mycobacteria is that of cooling towers of air-conditioning systems. Such environments not only harbor a variety of microbial species, they also disseminate them in aerosols. The present investigation examined nine cooling towers from various locations in the United States. Cooling tower water was concentrated, treated with cetylpyridinium chloride, and plated onto Middlebrook 7H10 agar supplemented with OADC and cycloheximide. Colonies presumed to be mycobacterial species were isolated and acid-fast stained. Identification was made by amplifying and sequencing 1450 bp fragments of the 16S rRNA gene in both directions, and comparing resulting sequences with those in GenBank. Results showed that at least 75% of tower samples contained NTMs, and most of the isolates closely matched known mycobacterial pathogens. Isolates most closely matched the following GenBank sequences: Mycobacterium intracellulare, M. szulgai, M. bohemicum, M. gordonae, M. nonchromogenicum, and M. n. sp. "Fuerth 1999." This is the first report of specific NTMs in cooling tower water, and the first report of M. n. sp. "Fuerth 1999" from any environmental sample. Although cooling towers have a relatively high pH, they may favor the growth and dissemination of such potential pathogens, and future epidemiologic investigations should consider cooling towers as possible environmental sources of mycobacteria.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Teets, William K.; Weintraub, David A.; Kastner, Joel H.
2012-11-20
EX Lupi is the prototype for a class of young, pre-main-sequence stars which are observed to undergo irregular, presumably accretion-generated, optical outbursts that result in a several magnitude rise of the optical flux. EX Lupi was observed to optically erupt in 2008 January, triggering Chandra ACIS Target of Opportunity observations shortly thereafter. We find very strong evidence that most of the X-ray emission in the first few months after the optical outburst is generated by accretion of circumstellar material onto the stellar photosphere. Specifically, we find a strong correlation between the decreasing optical and X-ray fluxes following the peak ofmore » the outburst in the optical, which suggests that these observed declines in both the optical and X-ray fluxes are the result of declining accretion rate. In addition, in our models of the X-ray spectrum, we find strong evidence for a {approx}0.4 keV plasma component, as expected for accretion shocks on low-mass, pre-main-sequence stars. From 2008 March through October, this cool plasma component appeared to fade as EX Lupi returned to its quiescent level in the optical, consistent with a decrease in the overall emission measure of accretion-shock-generated plasma. The overall small increase of the X-ray flux during the optical outburst of EX Lupi is similar to what was observed in previous X-ray observations of the 2005 optical outburst of the EX Lupi-type star V1118 Ori but contrasts with the large increase of the X-ray flux from the erupting young star V1647 Ori during its 2003 and 2008 optical outbursts.« less
NASA Technical Reports Server (NTRS)
Teets, William K.; Weintraub, David A.; Kastner, Joel H.; Grosso, Nicholas; Hamaguchi, Kenji; Richmond, Michael
2012-01-01
EX Lupi is the prototype for a class of young, pre-main-sequence stars which are observed to undergo irregular, presumably accretion-generated, optical outbursts that result in a several magnitude rise of the optical flux. EX Lupi was observed to optically erupt in 2008 January, triggering Chandra ACIS Target of Opportunity observations shortly thereafter. We find very strong evidence that most of the X-ray emission in the first few months after the optical outburst is generated by accretion of circumstellar material onto the stellar photosphere. Specifically, we find a strong correlation between the decreasing optical and X-ray fluxes following the peak of the outburst in the optical, which suggests that these observed declines in both the optical and X-ray fluxes are the result of declining accretion rate. In addition, in our models of the X-ray spectrum, we find strong evidence for an approx 0.4 keV plasma component, as expected for accretion shocks on low-mass, pre-main-sequence stars. From 2008 March through October, this cool plasma component appeared to fade as EX Lupi returned to its quiescent level in the optical, consistent with a decrease in the overall emission measure of accretion-shock-generated plasma. The overall small increase of the X-ray flux during the optical outburst of EX Lupi is similar to what was observed in previous X-ray observations of the 2005 optical outburst of the EX Lupi-type star V1118 Ori but contrasts with the large increase of the X-ray flux from the erupting young star V1647 Ori during its 2003 and 2008 optical outbursts.
NASA Astrophysics Data System (ADS)
Sung, Hyo Kyung; Shin, Sang Yong; Hwang, Byoungchul; Lee, Chang Gil; Kim, Nack J.; Lee, Sunghak
2011-07-01
Six ultra-low-carbon high-strength bainitic steel plates were fabricated by controlling rolling and cooling conditions, and effects of bainitic microstructure on tensile and Charpy impact properties were investigated. The microstructural evolution was more critically affected by start cooling temperature and cooling rate than by finish rolling temperature. Bainitic microstructures such as granular bainites (GBs) and bainitic ferrites (BFs) were well developed as the start cooling temperature decreased or the cooling rate increased. When the steels cooled from 973 K or 873 K (700 °C or 600 °C) were compared under the same cooling rate of 10 K/s (10 °C/s), the steels cooled from 973 K (700 °C) consisted mainly of coarse GBs, while the steels cooled from 873 K (600 °C) contained a considerable amount of BFs having high strength, thereby resulting in the higher strength but the lower ductility and upper shelf energy (USE). When the steels cooled from 673 K (400 °C) at a cooling rate of 10 K/s (10 °C/s) or 0.1 K/s (0.1 °C/s) were compared under the same start cooling temperature of 873 K (600 °C), the fast cooled specimens were composed mainly of coarse GBs or BFs, while the slowly cooled specimens were composed mainly of acicular ferrites (AFs). Since AFs had small effective grain size and contained secondary phases finely distributed at grain boundaries, the slowly cooled specimens had a good combination of strength, ductility, and USE, together with very low energy transition temperature (ETT).
Cool DZ white dwarfs II: compositions and evolution of old remnant planetary systems
NASA Astrophysics Data System (ADS)
Hollands, M. A.; Gänsicke, B. T.; Koester, D.
2018-06-01
In a previous study, we analysed the spectra of 230 cool (Teff < 9000 K) white dwarfs exhibiting strong metal contamination, measuring abundances for Ca, Mg, Fe and in some cases Na, Cr, Ti, or Ni. Here, we interpret these abundances in terms of the accretion of debris from extrasolar planetesimals, and infer parent body compositions ranging from crust-like (rich in Ca and Ti) to core-like (rich in Fe and Ni). In particular, two white dwarfs, SDSS J0823+0546 and SDSS J0741+3146, which show log [Fe/Ca] > 1.9 dex, and Fe to Ni ratios similar to the bulk Earth, have accreted by far the most core-like exoplanetesimals discovered to date. With cooling ages in the range 1-8 Gyr, these white dwarfs are among the oldest stellar remnants in the Milky Way, making it possible to probe the long-term evolution of their ancient planetary systems. From the decrease in maximum abundances as a function of cooling age, we find evidence that the arrival rate of material on to the white dwarfs decreases by three orders of magnitude over a ≃ 6.5 Gyr span in white dwarf cooling ages, indicating that the mass-reservoirs of post-main sequence planetary systems are depleted on a ≃ 1 Gyr e-folding time-scale. Finally, we find that two white dwarfs in our sample are members of wide binaries, and both exhibit atypically high abundances, thus providing strong evidence that distant binary companions can dynamically perturb white dwarf planetary systems.
White Dwarfs in the GALEX Survey
NASA Technical Reports Server (NTRS)
Kawka, Adela; Vennes, Stephane
2007-01-01
We have cross-correlated the 2dF QSO Redshift Survey (2QZ) white dwarf catalog with the GALEX 2nd Data Release and the Sloan Digital Sky Survey (SDSS) data release 5 to obtain ultraviolet photometry (FUV, NUV) for approximately 700 objects and optical photometry (ugriz) for approximately 800 objects. We have compared the optical-ultraviolet colors to synthetic white dwarf colors to obtain temperature estimates for approximately 250 of these objects. These white dwarfs have effective temperatures ranging from 10 000 K (cooling age of about 1Gyr) up to about 40000 K (cooling age of about 3 Myrs), with a few that have even higher temperatures. We found that to distinguish white dwarfs from other stellar luminosity classes both optical and ultraviolet colors are necessary, in particular for the hotter objects where there is contamination from B and 0 main-sequence stars. Using this sample we build a luminosity function for the DA white dwarfs with Mv < 12 mag.
Photometric Calibrations of Gemini Images of NGC 6253
NASA Astrophysics Data System (ADS)
Pearce, Sean; Jeffery, Elizabeth
2017-01-01
We present preliminary results of our analysis of the metal-rich open cluster NGC 6253 using imaging data from GMOS on the Gemini-South Observatory. These data are part of a larger project to observe the effects of high metallicity on white dwarf cooling processes, especially the white dwarf cooling age, which have important implications on the processes of stellar evolution. To standardize the Gemini photometry, we have also secured imaging data of both the cluster and standard star fields using the 0.6-m SARA Observatory at CTIO. By analyzing and comparing the standard star fields of both the SARA data and the published Gemini zero-points of the standard star fields, we will calibrate the data obtained for the cluster. These calibrations are an important part of the project to obtain a standardized deep color-magnitude diagram to analyze the cluster. We present the process of verifying our standardization process. With a standardized CMD, we also present an analysis of the cluster's main sequence turn off age.
Hyperquenched hyaloclastites from Axial Seamount
NASA Astrophysics Data System (ADS)
Zezin, D.; Helo, C.; Richard, D.; Clague, D. A.; Dingwell, D. B.; Stix, J.
2009-12-01
We determined apparent cooling rates for basaltic hyaloclastites from Axial caldera, Juan de Fuca Ridge. Samples originate from different stratigraphic layers within the unconsolidated volcaniclastic sequences, on flanks of the volcanic edifice. Water depth is ~1400 m below sea level. The hyaloclastite glass fragments comprise two principal morphologies: (1) angular fragments, and (2) thin glassy melt films interpreted as bubble walls, called deep-sea limu o Pele. A natural cooling rate was estimated for each sample of ~50 carefully selected glass shards. The heat capacity was first measured with a differential scanning calorimeter in two heating scans with heating rates of 20 K/min, and a matching cooling rate between those scans. The fictive temperatures Tf were then determined from both heating cycles, and the natural cooling rate derived by the non-Arrhenian relationship between Tf and cooling rate. All samples display hyperquenched states, manifested in a strong exothermic energy release during the initial heating cycle before reaching the glass transition. Cooling rates range from 10 6.73 K/s to 10 3.94 K/s for the limu, and 10 4.92 K/s to 10 2.34 K/s for the angular fragments. Almost all samples of limu shards show elevated cooling rates compared to their angular counterparts of comparable grain mass. In addition, the exothermic part of the enthalpy curves reveal two superimposed relaxation domains, the main broad exothermal peak, ranging from ~350 K to the onset of the glass transition, and a small subordinate peak/shoulder occurring between 550 K and 700 K. The magnitude of the latter varies from clearly identifiable to nearly absent, and tends to be more pronounced in curves obtained from angular fragments. The main exothermal peak is related to the frozen-in structure of the glass and consequently to its thermal history when passing through the glass transition. The subordinate peak may represent strain rate-induced and tensile stress accumulation-induced excess enthalpy. It could reveal certain aspects of the mechanical history of the fragments, and may imply flow at the onset of the viscoelastic regime in order to allow for stress-accumulation. The quench rates of the investigated hyaloclastites slightly exceed the limits of hyperquenched glass documented form Loihi Seamount, and are significantly higher than those of glassy pillow or sheet lava rims. Such short cooling timescales may only be achieved by fragmentation-coupled quenching, which allows for efficient heat conduction. This range of cooling rates spanning several orders of magnitude points towards a dynamic eruption environment with the possibility of multiple processes influencing cooling rates. The two types of glass shards may have experienced slightly different mechanical histories prior to quenching. Based on an interpretation of stress accumulation, strain rates are close to those necessary for the onset of non-Newtonian behaviour. To match the requirements of a dynamic environment with efficient fragmentation, rapid cooling, and high strain rates, we propose that the hyaloclastites are products of an explosive eruption environment.
Toward Genomics-Based Breeding in C3 Cool-Season Perennial Grasses.
Talukder, Shyamal K; Saha, Malay C
2017-01-01
Most important food and feed crops in the world belong to the C3 grass family. The future of food security is highly reliant on achieving genetic gains of those grasses. Conventional breeding methods have already reached a plateau for improving major crops. Genomics tools and resources have opened an avenue to explore genome-wide variability and make use of the variation for enhancing genetic gains in breeding programs. Major C3 annual cereal breeding programs are well equipped with genomic tools; however, genomic research of C3 cool-season perennial grasses is lagging behind. In this review, we discuss the currently available genomics tools and approaches useful for C3 cool-season perennial grass breeding. Along with a general review, we emphasize the discussion focusing on forage grasses that were considered orphan and have little or no genetic information available. Transcriptome sequencing and genotype-by-sequencing technology for genome-wide marker detection using next-generation sequencing (NGS) are very promising as genomics tools. Most C3 cool-season perennial grass members have no prior genetic information; thus NGS technology will enhance collinear study with other C3 model grasses like Brachypodium and rice. Transcriptomics data can be used for identification of functional genes and molecular markers, i.e., polymorphism markers and simple sequence repeats (SSRs). Genome-wide association study with NGS-based markers will facilitate marker identification for marker-assisted selection. With limited genetic information, genomic selection holds great promise to breeders for attaining maximum genetic gain of the cool-season C3 perennial grasses. Application of all these tools can ensure better genetic gains, reduce length of selection cycles, and facilitate cultivar development to meet the future demand for food and fodder.
Age Spreads and the Temperature Dependence of Age Estimates in Upper Sco
NASA Astrophysics Data System (ADS)
Fang, Qiliang; Herczeg, Gregory J.; Rizzuto, Aaron
2017-06-01
Past estimates for the age of the Upper Sco Association are typically 11–13 Myr for intermediate-mass stars and 4–5 Myr for low-mass stars. In this study, we simulate populations of young stars to investigate whether this apparent dependence of estimated age on spectral type may be explained by the star formation history of the association. Solar and intermediate mass stars begin their pre-main sequence evolution on the Hayashi track, with fully convective interiors and cool photospheres. Intermediate-mass stars quickly heat up and transition onto the radiative Henyey track. As a consequence, for clusters in which star formation occurs on a timescale similar to that of the transition from a convective to a radiative interior, discrepancies in ages will arise when ages are calculated as a function of temperature instead of mass. Simple simulations of a cluster with constant star formation over several Myr may explain about half of the difference in inferred ages versus photospheric temperature; speculative constructions that consist of a constant star formation followed by a large supernova-driven burst could fully explain the differences, including those between F and G stars where evolutionary tracks may be more accurate. The age spreads of low-mass stars predicted from these prescriptions for star formation are consistent with the observed luminosity spread of Upper Sco. The conclusion that a lengthy star formation history will yield a temperature dependence in ages is expected from the basic physics of pre-main sequence evolution, and is qualitatively robust to the large uncertainties in pre-main sequence evolutionary models.
LITHIUM DEPLETION IS A STRONG TEST OF CORE-ENVELOPE RECOUPLING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Somers, Garrett; Pinsonneault, Marc H., E-mail: somers@astronomy.ohio-state.edu
2016-09-20
Rotational mixing is a prime candidate for explaining the gradual depletion of lithium from the photospheres of cool stars during the main sequence. However, previous mixing calculations have relied primarily on treatments of angular momentum transport in stellar interiors incompatible with solar and stellar data in the sense that they overestimate the internal differential rotation. Instead, recent studies suggest that stars are strongly differentially rotating at young ages but approach a solid body rotation during their lifetimes. We modify our rotating stellar evolution code to include an additional source of angular momentum transport, a necessary ingredient for explaining the openmore » cluster rotation pattern, and examine the consequences for mixing. We confirm that core-envelope recoupling with a ∼20 Myr timescale is required to explain the evolution of the mean rotation pattern along the main sequence, and demonstrate that it also provides a more accurate description of the Li depletion pattern seen in open clusters. Recoupling produces a characteristic pattern of efficient mixing at early ages and little mixing at late ages, thus predicting a flattening of Li depletion at a few Gyr, in agreement with the observed late-time evolution. Using Li abundances we argue that the timescale for core-envelope recoupling during the main sequence decreases sharply with increasing mass. We discuss the implications of this finding for stellar physics, including the viability of gravity waves and magnetic fields as agents of angular momentum transport. We also raise the possibility of intrinsic differences in initial conditions in star clusters using M67 as an example.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fang Qiliang; Herczeg, Gregory J.; Rizzuto, Aaron
Past estimates for the age of the Upper Sco Association are typically 11–13 Myr for intermediate-mass stars and 4–5 Myr for low-mass stars. In this study, we simulate populations of young stars to investigate whether this apparent dependence of estimated age on spectral type may be explained by the star formation history of the association. Solar and intermediate mass stars begin their pre-main sequence evolution on the Hayashi track, with fully convective interiors and cool photospheres. Intermediate-mass stars quickly heat up and transition onto the radiative Henyey track. As a consequence, for clusters in which star formation occurs on amore » timescale similar to that of the transition from a convective to a radiative interior, discrepancies in ages will arise when ages are calculated as a function of temperature instead of mass. Simple simulations of a cluster with constant star formation over several Myr may explain about half of the difference in inferred ages versus photospheric temperature; speculative constructions that consist of a constant star formation followed by a large supernova-driven burst could fully explain the differences, including those between F and G stars where evolutionary tracks may be more accurate. The age spreads of low-mass stars predicted from these prescriptions for star formation are consistent with the observed luminosity spread of Upper Sco. The conclusion that a lengthy star formation history will yield a temperature dependence in ages is expected from the basic physics of pre-main sequence evolution, and is qualitatively robust to the large uncertainties in pre-main sequence evolutionary models.« less
NASA Astrophysics Data System (ADS)
Péron, Mael; Jacquemin, Frédéric; Casari, Pascal; Orange, Gilles; Bailleul, Jean-Luc; Boyard, Nicolas
2017-10-01
The prediction of process induced stresses during the cooling of thermoplastic composites still represents a challenge for the scientific community. However, a precise determination of these stresses is necessary in order to optimize the process conditions and thus lower the stresses effects on the final part health. A model is presented here, that permits the estimation of residual stresses during cooling. It relies on the nonlinear laminate theory, which has been adapted to arbitrary layup sequences. The developed model takes into account the heat transfers through the thickness of the laminate, together with the crystallization kinetics. The development of the composite mechanical properties during cooling is addressed by an incremental linear elastic constitutive law, which also considers thermal and crystallization strains. In order to feed the aforementioned model, a glass fiber and PA6.6 matrix unidirectional (UD) composite has been characterized. This work finally focuses on the identification of the material and process related parameters that lower the residual stresses level, including the ply sequence, the fiber volume fraction and the cooling rate.
Cooling system for a nuclear reactor
Amtmann, Hans H.
1982-01-01
A cooling system for a gas-cooled nuclear reactor is disclosed which includes at least one primary cooling loop adapted to pass coolant gas from the reactor core and an associated steam generator through a duct system having a main circulator therein, and at least one auxiliary cooling loop having communication with the reactor core and adapted to selectively pass coolant gas through an auxiliary heat exchanger and circulator. The main and auxiliary circulators are installed in a common vertical cavity in the reactor vessel, and a common return duct communicates with the reactor core and intersects the common cavity at a junction at which is located a flow diverter valve operative to effect coolant flow through either the primary or auxiliary cooling loops.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malamud, Uri; Perets, Hagai B., E-mail: uri.mal@tx.technion.ac.il, E-mail: hperets@physics.technion.ac.il
Most studies suggest that the pollution of white dwarf (WD) atmospheres arises from the accretion of minor planets, but the exact properties of polluting material, and in particular the evidence for water in some cases, are not yet understood. Here we study the water retention of small icy bodies in exo-solar planetary systems, as their respective host stars evolve through and off the main sequence and eventually become WDs. We explore, for the first time, a wide range of star masses and metallicities. We find that the mass of the WD progenitor star is of crucial importance for the retentionmore » of water, while its metallicity is relatively unimportant. We predict that minor planets around lower-mass WD progenitors would generally retain more water and would do so at closer distances from the WD than compared with high-mass progenitors. The dependence of water retention on progenitor mass and other parameters has direct implications for the origin of observed WD pollution, and we discuss how our results and predictions might be tested in the future as more observations of WDs with long cooling ages become available.« less
The Missing Link: Early Methane ("T") Dwarfs in the Sloan Digital Sky Survey.
Leggett; Geballe; Fan; Schneider; Gunn; Lupton; Knapp; Strauss; McDaniel; Golimowski; Henry; Peng; Tsvetanov; Uomoto; Zheng; Hill; Ramsey; Anderson; Annis; Bahcall; Brinkmann; Chen; Csabai; Fukugita; Hennessy; Hindsley; Ivezic; Lamb; Munn; Pier; Schlegel; Smith; Stoughton; Thakar; York
2000-06-10
We report the discovery of three cool brown dwarfs that fall in the effective temperature gap between the latest L dwarfs currently known, with no methane absorption bands in the 1-2.5 µm range, and the previously known methane (T) dwarfs, whose spectra are dominated by methane and water. The newly discovered objects were detected as very red objects in the Sloan Digital Sky Survey imaging data and have JHK colors between the red L dwarfs and the blue Gl 229B-like T dwarfs. They show both CO and CH(4) absorption in their near-infrared spectra in addition to H(2)O, with weaker CH(4) absorption features in the H and K bands than those in all other methane dwarfs reported to date. Due to the presence of CH(4) in these bands, we propose that these objects are early T dwarfs. The three form part of the brown dwarf spectral sequence and fill in the large gap in the overall spectral sequence from the hottest main-sequence stars to the coolest methane dwarfs currently known.
Boa, Kristof; Varga, Endre; Pinter, Gabor; Csonka, Akos; Gargyan, Istvan; Varga, Endre
2015-12-01
The purpose of this study was to measure the rise in intraosseous temperature caused by drilling through a drilling guide system. We compared the rise in temperature generated, and the number of increases of more than 10 °C, between drills that had been cooled with saline at room temperature (25 °C) and those that had not been cooled, for every step of the drilling sequence. Cortical layers of bovine ribs were used as specimens, and they were drilled through 3-dimensional printed surgical guides. Heat was measured with an infrared thermometer. The significance of differences was assessed with either a two-sample t test or Welch's test, depending on the variances. The mean rises (number of times that the temperature rose above 10 °C) for each group of measurements were: for the 2mm drill, 4.8 °C (0/48) when cooled and 7.0 °C (8/48) when not cooled; with the 2.5mm drill, 5.2 °C (1/48) when cooled and 8.5 °C (17/48) when not cooled (2 mm canal); with the 3 mm drill, 3.3 °C when cooled (0/48) and 8.5 °C (18/24) when not cooled (2.5 mm canal); and with the 3.5 mm drill, 4.8 °C when cooled (0/24) and 9.4 °C when not cooled (10/23) (3 mm canal). The temperature rose significantly less with cooling at every step of the drilling sequence (p<0.001). We conclude that external cooling can maintain the intraosseous temperature within the safe range while drilling through an implant guide system, whereas drilling without irrigation can lead to temperatures that exceed the acceptable limit. Copyright © 2015 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
The white-dwarf cooling sequence of NGC 6791: a unique tool for stellar evolution
NASA Astrophysics Data System (ADS)
García-Berro, E.; Torres, S.; Renedo, I.; Camacho, J.; Althaus, L. G.; Córsico, A. H.; Salaris, M.; Isern, J.
2011-09-01
Context. NGC 6791 is a well-studied, metal-rich open cluster that is so close to us that it can be imaged down to luminosities fainter than that of the termination of its white-dwarf cooling sequence, thus allowing for an in-depth study of its white dwarf population. Aims: White dwarfs carry important information about the history of the cluster. We use observations of the white-dwarf cooling sequence to constrain important properties of the cluster stellar population, such as the existence of a putative population of massive helium-core white dwarfs, and the properties of a large population of unresolved binary white dwarfs. We also investigate the use of white dwarfs to disclose the presence of cluster subpopulations with a different initial chemical composition, and we obtain an upper bound to the fraction of hydrogen-deficient white dwarfs. Methods: We use a Monte Carlo simulator that employs up-to-date evolutionary cooling sequences for white dwarfs with hydrogen-rich and hydrogen-deficient atmospheres, with carbon-oxygen and helium cores. The cooling sequences for carbon-oxygen cores account for the delays introduced by both 22Ne sedimentation in the liquid phase and by carbon-oxygen phase separation upon crystallization. Results: We do not find evidence for a substantial fraction of helium-core white dwarfs, and hence our results support the suggestion that the origin of the bright peak of the white-dwarf luminosity function can only be attributed to a population of unresolved binary white dwarfs. Moreover, our results indicate that if this hypothesis is at the origin of the bright peak, the number distribution of secondary masses of the population of unresolved binaries has to increase with increasing mass ratio between the secondary and primary components of the progenitor system. We also find that the observed cooling sequence appears to be able to constrain the presence of progenitor subpopulations with different chemical compositions and the fraction of hydrogen-deficient white dwarfs. Conclusions: Our simulations place interesting constraints on important characteristics of the stellar populations of NGC 6791. In particular, we find that the fraction of single helium-core white dwarfs must be smaller than 5%, that a subpopulation of stars with zero metallicity must be ≲12%, while if the adopted metallicity of the subpopulation is solar the upper limit is ~8%. Finally, we also find that the fraction of hydrogen-deficient white dwarfs in this particular cluster is surprinsingly small (≲6%).
Mass loss from red giants - Results from ultraviolet spectroscopy
NASA Technical Reports Server (NTRS)
Linsky, J. L.
1985-01-01
New instrumentation in space, primarily the IUE spacecraft, has enabled the application of ultraviolet spectroscopic techniques to the determination of physical properties and reliable mass loss rates for red giant winds. One important result is the determination of where in the H-R diagram are found stars with hot outer atmospheres and with cool winds. So far it appears that single cool stars, except perhaps the so-called hybrid stars, have either hot outer atmospheres or cool winds but not both. The C II resonance (1335 A) and intersystem (2325 A) multiplets have been used to derive temperatures, densities, and geometrical extents for the chromospheric portions of red giant winds, with the result that the red giants and the earlier giants with hot coronae have qualitatively different chromospheres. Mass loss rates can now be derived accurately from the analysis of asymmetric emission lines, such as the Mg II resonance lines, and from P Cygni profile lines of atoms in the dominant ionization stage when a hot star is available to probe the wind of a red giant. The Zeta Aur systems, consisting of a K-M supergiant and a main sequence B star are important systems for reliable mass loss rates for the red supergiant components are becoming available.
Development of a feed monitor system for a helium-cooled Michelson intererometer for the Spacelab
NASA Technical Reports Server (NTRS)
Essenwanger, P.
1980-01-01
A Michelson interferometer feed monitor system developed for Spacelab is described. The device is helium cooled and is to be used to measure far infrared radiation sources in space. Performance data and development sequence are presented.
Microstructural indicators of convection in sills and dykes
NASA Astrophysics Data System (ADS)
Holness, Marian; Neufeld, Jerome; Gilbert, Andrew
2016-04-01
The question of whether or not magma convects is a vexed one, with some advocating vigorous convection in crustal magma chambers while others suggest that convection is weak and short-lived. From a detailed microstructural study of a range of tabular mafic intrusions, we argue that it is possible to determine whether crystallization took place predominantly in solidification fronts (i.e. the magma was essentially crystal-free) or whether crystals grew suspended in a convecting magma. The 168m thick Shiant Isles Main Sill is a composite body, dominated by a 140m thick unit with a 45m thick base rich in olivine phenocrysts (picrodolerite). The remainder of the unit contains only interstitial olivine. The average olivine grain size in the picrodolerite decreases upwards in the lowermost 10m, but then increases upwards. The coarsening-upwards sequence is marked by the onset of clustering of olivine grains. The extent to which these clusters are sintered, and the average cluster size, increase upwards. The coarsening-upwards sequence and the clustering are mirrored in a thinner (<10m) sequence at the roof. The fining-upwards sequence of non-clustered olivine formed by the rapid settling of incoming cargo crystals, while the coarsening-upwards sequence of clustered olivine represents post-emplacement growth of grains suspended in a convecting magma. The clusters grew by synneusis, with the extensive sintering pointing to the retention of the clusters in the convecting magma for a considerable time. The presence of large clusters at the intrusion roof can be reconciled with their high Stokes settling velocity if they were brought up in rapidly moving convective currents and entangled in the downwards-propagating solidification front. A further indication of convection is provided by plagioclase grain shape. During interface-controlled growth, plagioclase grows as well-facetted compact grains: these grains are platy in rapidly-cooled rocks and blocky in slowly-cooled rocks. In mafic sills, the average apparent aspect ratio (AR), as measured in thin-section, varies smoothly with model crystallization times (calculated assuming diffusive heat loss), consistent with in situ growth in solidification fronts. However, AR is invariant across individual mafic dykes, with decreasing values (i.e. more blocky grains) as the dyke width increases. This difference can be accounted for by the plagioclase in dykes growing as individual grains and clusters suspended in a convecting magma. Cooling at a vertical wall, as is the case for dykes, will always result in a gravitational convective instability, and therefore crystal-poor magma in dykes will always convect. As solidification proceeds, the increasing volume fraction of suspended crystals will eventually damp convection: the final stages of solidification occur in static crystal-rich magma, containing a well-mixed grain population. That the Shiant Isles Main Sill exhibits evidence for prolonged convection of sufficient vigour to suspend 5 mm olivine clusters, while other sills of comparable thickness contain plagioclase with grain shapes indicative of growth predominantly in solidification fronts, is most likely due to the composite nature of the Shiant. The 140m unit is underlain by 23m of picrite which intruded shortly before - this heat source would have acted as a strong driver for convection.
Thornley, C N; Harte, D J; Weir, R P; Allen, L J; Knightbridge, K J; Wood, P R T
2017-08-01
A legionellosis outbreak at an industrial site was investigated to identify and control the source. Cases were identified from disease notifications, workplace illness records, and from clinicians. Cases were interviewed for symptoms and risk factors and tested for legionellosis. Implicated environmental sources were sampled and tested for legionella. We identified six cases with Legionnaires' disease and seven with Pontiac fever; all had been exposed to aerosols from the cooling towers on the site. Nine cases had evidence of infection with either Legionella pneumophila serogroup (sg) 1 or Legionella longbeachae sg1; these organisms were also isolated from the cooling towers. There was 100% DNA sequence homology between cooling tower and clinical isolates of L. pneumophila sg1 using sequence-based typing analysis; no clinical L. longbeachae isolates were available to compare with environmental isolates. Routine monitoring of the towers prior to the outbreak failed to detect any legionella. Data from this outbreak indicate that L. pneumophila sg1 transmission occurred from the cooling towers; in addition, L. longbeachae transmission was suggested but remains unproven. L. longbeachae detection in cooling towers has not been previously reported in association with legionellosis outbreaks. Waterborne transmission should not be discounted in investigations for the source of L. longbeachae infection.
NASA Astrophysics Data System (ADS)
Dröske, Nils C.; Förster, Felix J.; Weigand, Bernhard; von Wolfersdorf, Jens
2017-03-01
In this paper, we present a combined experimental and numerical approach to assess the thermal loads and the cooling mechanism of an internally cooled strut injector for a supersonic combustion ramjet. Infrared measurements of the injector surface are conducted at a moderate external flow temperature. In addition, the main flow field is investigated with the LITA technique. Main features of the cooling mechanism are identified based on experimental data. However, a full evaluation can only be obtained using a complex, conjugate CFD simulation, which couples the external and internal flow fields to the heat conduction inside the injector body. Furthermore, numerical simulations are also presented for hot gas conditions corresponding to combustion experiments. Both hydrogen, which would be used as fuel for flight tests, and air are considered as coolants. While the main features of the cooling mechanism will be shown to remain unchanged, the combustor wall temperature is found to have a significant influence on the cooling. This emphasizes the importance and the usefulness of such complex conjugate numerical simulations.
System for tuning a combustor of a gas turbine
Hughes, Michael John
2016-12-27
A system for tuning a combustor of a gas turbine includes a flow sleeve having an annular main body. The main body includes an upstream end, a downstream end, an inner surface and an outer surface. A cooling channel extends along the inner surface of the main body. The cooling channel extends at least partially between the downstream end and the upstream end of the main body.
Yong, Stacey Foong Yee; Goh, Fen-Ning; Ngeow, Yun Fong
2010-03-01
In this study, we investigated the distribution of Legionella species in water cooling towers located in different parts of Malaysia to obtain information that may inform public health policies for the prevention of legionellosis. A total of 20 water samples were collected from 11 cooling towers located in three different states in east, west and south Malaysia. The samples were concentrated by filtration and treated with an acid buffer before plating on to BCYE agar. Legionella viable counts in these samples ranged from 100 to 2,000 CFU ml(-1); 28 isolates from the 24 samples were examined by latex agglutination as well as 16S rRNA and rpoB PCR-DNA sequencing. These isolates were identified as Legionella pneumophila serogroup 1 (35.7%), L. pneumophila serogroup 2-14 (39%), L. pneumophila non-groupable (10.7%), L. busanensis, L. gormanii, L. anisa and L. gresilensis. L. pneumophila was clearly the predominant species at all sampling sites. Repeat sampling from the same cooling tower and testing different colonies from the same water sample showed concurrent colonization by different serogroups and different species of Legionella in some of the cooling towers.
NASA Astrophysics Data System (ADS)
Tremblay, P.-E.; Gentile-Fusillo, N.; Cummings, J.; Jordan, S.; Gänsicke, B. T.; Kalirai, J. S.
2018-04-01
The vast majority of stars will become white dwarfs at the end of the stellar life cycle. These remnants are precise cosmic clocks owing to their well constrained cooling rates. Gaia Data Release 2 is expected to discover hundreds of thousands of white dwarfs, which can then be observed spectroscopically with WEAVE and 4MOST. By employing spectroscopically derived atmospheric parameters combined with Gaia parallaxes, white dwarfs can constrain the stellar formation history in the early developing phases of the Milky Way, the initial mass function in the 1.5 to 8 M ⊙ range, and the stellar mass loss as well as the state of planetary systems during the post main-sequence evolution.
NASA Technical Reports Server (NTRS)
Wade, Richard A.; Stark, M. A.; Green, Richard F.; Durrell, Patrick R.
2009-01-01
The hot subdwarf (sd) stars in the Palomar Green (PG) catalog of ultraviolet excess (UVX) objects play a key role in investigations of the frequency and types of binary companions and the distribution of orbital periods. These are important for establishing whether and by which channels the sd stars arise from interactions in close binary systems. It has been suggested that the list of PG sd stars is biased by the exclusion of many stars in binaries, whose spectra show the Ca I1 K line in absorption. A total of 1125 objects that were photometrically selected as candidates were ultimately rejected from the final PG catalog using this K-line criterion. We study 88 of these 'PG-Rejects' (PGRs), to assess whether there are significant numbers of unrecognized sd stars in binaries among the PGR objects. The presence of a sd should cause a large UVX, compared with the cool K-line star. We assemble GALEX, Johnson V, and 2MASS photometry and compare the colors of these PGR objects with those of known sd stars, cool single stars, and hot+cool binaries. Sixteen PGRs were detected in both the far- and near-ultraviolet GALEX passbands. Eleven of these, plus the 72 cases with only an upper limit in the far-ultraviolet band, are interpreted as single cool stars, appropriately rejected by the PG spectroscopy. Of the remaining five stars, three are consistent with being sd stars paired with a cool main sequence companion, while two may be single stars or composite systems of another type. We discuss the implications of these findings for the 1125 PGR objects as a whole. An enlarged study is desirable to increase confidence in these first results and to identify individual sd+cool binaries or other composites for follow-up study. The GALEX AIS data have sufficient sensitivity to carry out this larger study.
Large Eddy simulation of flat plate film cooling at high blowing ratio using open FOAM
NASA Astrophysics Data System (ADS)
Baagherzadeh Hushmandi, Narmin
2017-12-01
In this work, numerical analysis was performed to predict the behaviour of high Reynolds number turbulent cross-flows used in film cooling applications. The geometry included one row of three discrete coolant holes inclined at 30 degrees to the main flow. In the computational model, the width of the channel was cut into one sixth and symmetry boundaries were applied in the centreline of the coolant hole and along the line of symmetry between two adjacent holes. One of the main factors that affect the performance of film cooling is the blowing ratio of coolant to the main flow. A blowing ratio equal to two was chosen in this study. Analysis showed that the common practice CFD models that employ RANS equations together with turbulence modelling under predict the film cooling effectiveness up to a factor of four. However, LES method showed better agreement of film cooling effectiveness both in tendency and absolute values compared with experimental results.
Large Eddy simulation of flat plate film cooling at high blowing ratio using open FOAM
NASA Astrophysics Data System (ADS)
Baagherzadeh Hushmandi, Narmin
2018-06-01
In this work, numerical analysis was performed to predict the behaviour of high Reynolds number turbulent cross-flows used in film cooling applications. The geometry included one row of three discrete coolant holes inclined at 30 degrees to the main flow. In the computational model, the width of the channel was cut into one sixth and symmetry boundaries were applied in the centreline of the coolant hole and along the line of symmetry between two adjacent holes. One of the main factors that affect the performance of film cooling is the blowing ratio of coolant to the main flow. A blowing ratio equal to two was chosen in this study. Analysis showed that the common practice CFD models that employ RANS equations together with turbulence modelling under predict the film cooling effectiveness up to a factor of four. However, LES method showed better agreement of film cooling effectiveness both in tendency and absolute values compared with experimental results.
NASA Astrophysics Data System (ADS)
Meyer, D. M.-A.; Mackey, J.; Langer, N.; Gvaramadze, V. V.; Mignone, A.; Izzard, R. G.; Kaper, L.
2014-11-01
At least 5 per cent of the massive stars are moving supersonically through the interstellar medium (ISM) and are expected to produce a stellar wind bow shock. We explore how the mass-loss and space velocity of massive runaway stars affect the morphology of their bow shocks. We run two-dimensional axisymmetric hydrodynamical simulations following the evolution of the circumstellar medium of these stars in the Galactic plane from the main sequence to the red supergiant phase. We find that thermal conduction is an important process governing the shape, size and structure of the bow shocks around hot stars, and that they have an optical luminosity mainly produced by forbidden lines, e.g. [O III]. The Hα emission of the bow shocks around hot stars originates from near their contact discontinuity. The Hα emission of bow shocks around cool stars originates from their forward shock, and is too faint to be observed for the bow shocks that we simulate. The emission of optically thin radiation mainly comes from the shocked ISM material. All bow shock models are brighter in the infrared, i.e. the infrared is the most appropriate waveband to search for bow shocks. Our study suggests that the infrared emission comes from near the contact discontinuity for bow shocks of hot stars and from the inner region of shocked wind for bow shocks around cool stars. We predict that, in the Galactic plane, the brightest, i.e. the most easily detectable bow shocks are produced by high-mass stars moving with small space velocities.
Zhang, Leyi; Li, Yi; Wang, Xin; Shangguan, Zhihui; Zhou, Haijian; Wu, Yuejin; Wang, Lianghuai; Ren, Hongyu; Hu, Yun; Lin, Meifen; Qin, Tian
2017-02-24
Natural and engineered water systems are the main sources of Legionnaires' disease. It is essential from a public health perspective to survey water environments for the existence of Legionella . To analyze the main serogroups, genotypes and pathogenicity of the pathogen, a stratified sampling method was adopted to collect water samples randomly from shower water, cooling tower water, and local public hot springs in Wenzhou, China. Suspected strains were isolated from concentrated water samples. Serum agglutination assay and real-time PCR (Polymerase chain reaction) were used to identify L. pneumophila . Sequence-based typing (SBT) and pulsed-field gel electrophoresis (PFGE) were used to elucidate the genetic polymorphisms in the collected isolates. The intracellular growth ability of the isolates was determined through their interaction with J774 cells and plating them onto BCYE (Buffered Charcoal Yeast Extract) agar plates. Overall, 25.56% (46/180) of water samples were Legionella -positive; fifty-two strains were isolated and two kinds of serogroups were co-detected from six water samples from 2015 to 2016. Bacterial concentrations ranged from 20 CFU/100 mL to 10,720 CFU/100 mL. In detail, the Legionella -positive rates of shower water, cooling tower water and hot springs water were 15.45%, 13.33%, and 62.5%, respectively. The main serogroups were LP1 (30.69%) and LP3 (28.85%) and all strains carried the dot gene. Among them, 52 isolates and another 10 former isolates were analyzed by PFGE. Nineteen distinct patterns were observed in 52 strains isolated from 2015 to 2016 with three patterns being observed in 10 strains isolated from 2009 to 2014. Seventy-three strains containing 52 from this study and 21 former isolates were selected for SBT analysis and divided into 25 different sequence types in 4 main clonal groups belonging to 4 homomorphic types. Ten strains were chosen to show their abilities to grow and multiply in J744 cells. Taken together, our results demonstrate a high prevalence and genetic polymorphism of Legionella in Wenzhou's environmental water system. The investigated environmental water sources pose a potential threat to the public where intervention could help to prevent the occurrence of Legionnaires' disease.
Zhang, Leyi; Li, Yi; Wang, Xin; Shangguan, Zhihui; Zhou, Haijian; Wu, Yuejin; Wang, Lianghuai; Ren, Hongyu; Hu, Yun; Lin, Meifen; Qin, Tian
2017-01-01
Natural and engineered water systems are the main sources of Legionnaires’ disease. It is essential from a public health perspective to survey water environments for the existence of Legionella. To analyze the main serogroups, genotypes and pathogenicity of the pathogen, a stratified sampling method was adopted to collect water samples randomly from shower water, cooling tower water, and local public hot springs in Wenzhou, China. Suspected strains were isolated from concentrated water samples. Serum agglutination assay and real-time PCR (Polymerase chain reaction) were used to identify L. pneumophila. Sequence-based typing (SBT) and pulsed-field gel electrophoresis (PFGE) were used to elucidate the genetic polymorphisms in the collected isolates. The intracellular growth ability of the isolates was determined through their interaction with J774 cells and plating them onto BCYE (Buffered Charcoal Yeast Extract) agar plates. Overall, 25.56% (46/180) of water samples were Legionella-positive; fifty-two strains were isolated and two kinds of serogroups were co-detected from six water samples from 2015 to 2016. Bacterial concentrations ranged from 20 CFU/100 mL to 10,720 CFU/100 mL. In detail, the Legionella-positive rates of shower water, cooling tower water and hot springs water were 15.45%, 13.33%, and 62.5%, respectively. The main serogroups were LP1 (30.69%) and LP3 (28.85%) and all strains carried the dot gene. Among them, 52 isolates and another 10 former isolates were analyzed by PFGE. Nineteen distinct patterns were observed in 52 strains isolated from 2015 to 2016 with three patterns being observed in 10 strains isolated from 2009 to 2014. Seventy-three strains containing 52 from this study and 21 former isolates were selected for SBT analysis and divided into 25 different sequence types in 4 main clonal groups belonging to 4 homomorphic types. Ten strains were chosen to show their abilities to grow and multiply in J744 cells. Taken together, our results demonstrate a high prevalence and genetic polymorphism of Legionella in Wenzhou’s environmental water system. The investigated environmental water sources pose a potential threat to the public where intervention could help to prevent the occurrence of Legionnaires’ disease. PMID:28245548
ASCA Observations of the T Tauri Star SU Aurigae and the Surrounding L1517 Dark Cloud
NASA Technical Reports Server (NTRS)
Skinner, Stephen L.; Walter, Frederick M.
1998-01-01
We present the results of a approximately equals 40 ks pointed Advanced Satellite for Cosmology and Astrophysics (ASCA) observation of the L1517 star-forming region, centered on the X-ray-bright T Tauri star SU Aurigae. This star has the highest X-ray luminosity of any classical T Tauri star in the Taurus-Auriga region, and its optical spectra show evidence for both mass inflow and outflow. Strong X-ray emission was detected from SU Aur (L(sub x) = 10(exp 30.9) ergs s(exp -1)) as well as weaker emission from five other pre-main-sequence stars. Although no large-amplitude flares were detected, the X-ray emission of SU Aur showed clear variability in the form of a slow decline in count rate during the 1.3 day observation. We provide the first direct comparison of the coronal differential emission measure (DEM) distribution of a classical T Tauri star with that of a young main-sequence star of similar spectral type. The DEM distributions of SU Aur (G2; age 3 Myr) and the young solar-like star EK Draconis (GO V; age 70 Myr) are qualitatively similar, with both showing a bimodal temperature distribution characterized by a cool plasma component peaking at approximately 8-9 MK and a hot component peaking at approximately 20-21 MK. However, there is a striking difference in the relative proportion of plasma at high temperatures in the two stars, with hot plasma (>20 MK) accounting for approximately equals 80% of the volume emission measure of SU Aur, compared to only approximately equals 40% in EK Dra. These results provide new insight into the changes that will occur in the corona of a T Tauri star as it descends onto the main sequence. A sharp decline in the fraction of coronal plasma at flarelike temperatures will occur during the late-T Tauri and post-T Tauri phases, and other recent X-ray studies have shown that this decline will continue after the young solar-like star reaches the main sequence.
Amemura-Maekawa, Junko; Kura, Fumiaki; Chang, Bin; Suzuki-Hashimoto, Atsuko; Ichinose, Masayuki; Endo, Takuro; Watanabe, Haruo
2008-09-01
To investigate the genetic difference of Legionella pneumophila in human-made environments, we collected isolates of L. pneumophila from bath water (n = 167) and cooling tower water (n = 128) primarily in the Kanto region in 2001 and 2005. The environmental isolates were serogrouped and sequenced for a target region of flaA. A total of 14 types of flaA genotypes were found: 10 from cooling tower water and nine from bath water. The flaA genotypes of isolates from cooling tower water were quite different from those of bath water.
Cooling System: Automotive Mechanics Instructional Program. Block 6.
ERIC Educational Resources Information Center
O'Brien, Ralph D.
The last of six instructional blocks in automotive mechanics, the lessons and supportive information in the document provide a guide for teachers in planning an instructional program in the automotive cooling system at the secondary and post secondary level. The material, as organized, is a suggested sequence of instruction within each block. Each…
USDA-ARS?s Scientific Manuscript database
Rice drying with infrared (IR) radiation has been investigated during recent years and showed promising potential with improved quality and energy efficiency. The objective of this study was to further investigate the moisture removal characteristics of thin layer rough rice heated by IR and cooled ...
Wéry, Nathalie; Bru-Adan, Valérie; Minervini, Céline; Delgénes, Jean-Philippe; Garrelly, Laurent; Godon, Jean-Jacques
2008-05-01
The dynamics of Legionella spp. and of dominant bacteria were investigated in water from a cooling tower plant over a 9-month period which included several weeks when Legionella pneumophila proliferated. The structural diversity of both the bacteria and the Legionella spp. was monitored by a fingerprint technique, single-strand conformation polymorphism, and Legionella spp. and L. pneumophila were quantified by real-time quantitative PCR. The structure of the bacterial community did not change over time, but it was perturbed periodically by chemical treatment or biofilm detachment. In contrast, the structure of the Legionella sp. population changed in different periods, its dynamics at times showing stability but also a rapid major shift during the proliferation of L. pneumophila in July. The dynamics of the Legionella spp. and of dominant bacteria were not correlated. In particular, no change in the bacterial community structure was observed during the proliferation of L. pneumophila. Legionella spp. present in the cooling tower system were identified by cloning and sequencing of 16S rRNA genes. A high diversity of Legionella spp. was observed before proliferation, including L. lytica, L. fallonii, and other Legionella-like amoebal pathogen types, along with as-yet-undescribed species. During the proliferation of L. pneumophila, Legionella sp. diversity decreased significantly, L. fallonii and L. pneumophila being the main species recovered.
Wéry, Nathalie; Bru-Adan, Valérie; Minervini, Céline; Delgénes, Jean-Philippe; Garrelly, Laurent; Godon, Jean-Jacques
2008-01-01
The dynamics of Legionella spp. and of dominant bacteria were investigated in water from a cooling tower plant over a 9-month period which included several weeks when Legionella pneumophila proliferated. The structural diversity of both the bacteria and the Legionella spp. was monitored by a fingerprint technique, single-strand conformation polymorphism, and Legionella spp. and L. pneumophila were quantified by real-time quantitative PCR. The structure of the bacterial community did not change over time, but it was perturbed periodically by chemical treatment or biofilm detachment. In contrast, the structure of the Legionella sp. population changed in different periods, its dynamics at times showing stability but also a rapid major shift during the proliferation of L. pneumophila in July. The dynamics of the Legionella spp. and of dominant bacteria were not correlated. In particular, no change in the bacterial community structure was observed during the proliferation of L. pneumophila. Legionella spp. present in the cooling tower system were identified by cloning and sequencing of 16S rRNA genes. A high diversity of Legionella spp. was observed before proliferation, including L. lytica, L. fallonii, and other Legionella-like amoebal pathogen types, along with as-yet-undescribed species. During the proliferation of L. pneumophila, Legionella sp. diversity decreased significantly, L. fallonii and L. pneumophila being the main species recovered. PMID:18390683
Pereira, Rui P A; Peplies, Jörg; Höfle, Manfred G; Brettar, Ingrid
2017-10-01
Cooling towers are the major source of outbreaks of legionellosis in Europe and worldwide. These outbreaks are mostly associated with Legionella species, primarily L. pneumophila, and its surveillance in cooling tower environments is of high relevance to public health. In this study, a combined NGS-based approach was used to study the whole bacterial community, specific waterborne and water-based bacterial pathogens, especially Legionella species, targeting the 16S rRNA gene. This approach was applied to water from a cooling tower obtained by monthly sampling during two years. The studied cooling tower was an open circuit cooling tower with lamellar cooling situated in Braunschweig, Germany. A highly diverse bacterial community was observed with 808 genera including 25 potentially pathogenic taxa using universal 16S rRNA primers. Sphingomonas and Legionella were the most abundant pathogenic genera. By applying genus-specific primers for Legionella, a diverse community with 85 phylotypes, and a representative core community with substantial temporal heterogeneity was observed. A high percentage of sequences (65%) could not be affiliated to an acknowledged species. L. pneumophila was part of the core community and the most abundant Legionella species reinforcing the importance of cooling towers as its environmental reservoir. Major temperature shifts (>10 °C) were the key environmental factor triggering the reduction or dominance of the Legionella species in the Legionella community dynamics. In addition, interventions by chlorine dioxide had a strong impact on the Legionella community composition but not on the whole bacterial community. Overall, the presented results demonstrated the value of a combined NGS approach for the molecular monitoring and surveillance of health related pathogens in man-made freshwater systems. Copyright © 2017 Elsevier Ltd. All rights reserved.
Using White Dwarf Companions of Blue Stragglers to Constrain Mass Transfer Physics
NASA Astrophysics Data System (ADS)
Gosnell, Natalie M.; Leiner, Emily; Geller, Aaron M.; Knigge, Christian; Mathieu, Robert D.; Sills, Alison; Leigh, Nathan
2018-06-01
Complete membership studies of old open clusters reveal that 25% of the evolved stars follow pathways in stellar evolution that are impacted by binary evolution. Recent studies show that the majority of blue straggler stars, traditionally defined to be stars brighter and bluer than the corresponding main sequence turnoff, are formed through mass transfer from a giant star onto a main sequence companion, resulting in a white dwarf in a binary system with a blue straggler. We will present constraints on the histories and mass transfer efficiencies for two blue straggler-white dwarf binaries in open cluster NGC 188. The constraints are a result of measuring white dwarf cooling temperatures and surface gravities with HST COS far-ultraviolet spectroscopy. This information sets both the timeline for mass transfer and the stellar masses in the pre-mass transfer binary, allowing us to constrain aspects of the mass transfer physics. One system is formed through Case C mass transfer, leaving a CO-core white dwarf, and provides an interesting test case for mass transfer from an asymptotic giant branch star in an eccentric system. The other system formed through Case B mass transfer, leaving a He-core white dwarf, and challenges our current understanding of the expected regimes for stable mass transfer from red giant branch stars.
The energy balance in coronal holes and average quiet-sun regions
NASA Technical Reports Server (NTRS)
Raymond, J. C.; Doyle, J. G.
1981-01-01
Emission measure curves are presented for average coronal hole and quiet-sun spectra taken during the Skylab mission by Vernazza and Reeves (1978), and the curves are used to discuss the energy balance in each region. Close-coupling calculations are used for the Be sequence, assuming a 10 level ion; for B sequence ions mainly distorted wave calculations in an 11 level ion are used, but close-coupling cross sections are used for some ions; for C and Mg sequence ions, distorted wave calculations are used with 15 and 10 level ions, respectively, and close-coupling results are used for Li-like ions with two levels. Results are presented and include the following: the coronal hole spectrum shows a smaller slope in the emission measure distribution, consistent with the expected outflow effects. It is concluded that the simple constant pressure models of static coronal loops of constant cross section are basically able to match the observed emission measure distribution of the average quiet sun between 1,000,000 and 10,000,000 K. However, the cell center and network distributions are respectively steeper and shallower than predicted by the detailed cooling curve.
NASA Astrophysics Data System (ADS)
Mathew, George; De Sarkar, Sharmistha; Pande, Kanchan; Dutta, Suryendu; Ali, Shakir; Rai, Apritam; Netrawali, Shilpa
2013-09-01
Determination of the peak thermal condition is vital in order to understand tectono-thermal evolution of the Himalayan belt. The Lesser Himalayan Sequence (LHS) in the Western Arunachal Pradesh, being rich in carbonaceous material (CM), facilitates the determination of peak metamorphic temperature based on Raman spectroscopy of carbonaceous material (RSCM). In this study, we have used RSCM method of Beyssac et al. (J Metamorph Geol 20:859-871, 2002a) and Rahl et al. (Earth Planet Sci Lett 240:339-354, 2005) to estimate the thermal history of LHS and Siwalik foreland from the western Arunachal Pradesh. The study indicates that the temperature of 700-800 °C in the Greater Himalayan Sequence (GHS) decreases to 650-700 °C in the main central thrust zone (MCTZ) and decreases further to <200 °C in the Mio-Pliocene sequence of Siwaliks. The work demonstrates greater reliability of Rahl et al.'s (Earth Planet Sci Lett 240:339-354, 2005) RSCM method for temperatures >600 and <340 °C. We show that the higher and lower zones of Bomdila Gneiss (BG) experienced temperature of ~600 °C and exhumed at different stages along the Bomdila Thrust (BT) and Upper Main Boundary Thrust (U.MBT). Pyrolysis analysis of the CM together with the Fission Track ages from upper Siwaliks corroborates the RSCM thermometry estimate of ~240 °C. The results indicate that the Permian sequence north of Lower MBT was deposited at greater depths (>12 km) than the upper Siwalik sediments to its south at depths <8 km before they were exhumed. The 40Ar/39Ar ages suggest that the upper zones of Se La evolved ~13-15 Ma. The middle zone exhumed at ~11 Ma and lower zone close to ~8 Ma indicating erosional unroofing of the MCT sheet. The footwall of MCTZ cooled between 6 and 8 Ma. Analyses of P-T path imply that LHS between MCT and U.MBT zone falls within the kyanite stability field with near isobaric condition. At higher structural level, the temperatures increase gradually with P-T conditions in the sillimanite stability field. The near isothermal (700-800 °C) condition in the GHS, isobaric condition in the MCTZ together with T-t path evidence of GHS that experienced relatively longer duration of near peak temperatures and rapid cooling towards MCTZ, compares the evolution of GHS and inverted metamorphic gradient closely to channel flow predictions.
[Effectiveness of scalp cooling in chemotherapy].
Poder, Thomas G; He, Jie; Lemieux, Renald
2011-10-01
The main objectives of this literature review are to determine if scalp cooling is efficient and safe, if there are side effects and if the patients' quality of life improves. In terms of effectiveness, scalp cooling seems to get good performance in its aim to prevent hair loss in patients receiving chemotherapy. The weighted average results of all identified studies indicate that this technology allows for 63.5% of patients to have a good preservation of their hair. In studies with a group of control, the weighted rates of good preservation of the hair are 50.6% with scalp cooling and 16.3% without. From the standpoint of safety technology, the main risk is that of scalp metastases. However, no study has successfully demonstrated a statistically significant difference between groups of patients receiving chemotherapy with or without scalp cooling.
Tracing Low-Mass Star Formation in the Magellanic Clouds
NASA Astrophysics Data System (ADS)
Petr-Gotzens, Monika; Zivkov, V.; Oliveira, J.
2017-06-01
Star formation in low metallicity environments is evidently occurring under different conditions than in our Milky Way. Lower metallicity implies a lower dust to gas ratio, most likely leading to less cooling efficiency at high density molecular cores where low mass stars are expected to form. We outline a project that aims to identify the low mass pre-main sequence populations within the Large and Small Magellanic Cloud. We developed an automatic detection algorithm that systematically analyses near-infrared colour-magnitude diagrammes constructed from the VMC (VISTA Magellanic Clouds) public survey data. In this poster we present our first results that show that we are able to detect significant numbers of PMS stars with masses down to 1.5 solar mass.
The tidal disruption of a star by a massive black hole
NASA Technical Reports Server (NTRS)
Evans, Charles R.; Kochanek, Christopher S.
1989-01-01
Results are reported from a three-dimensional numerical calculation of the tidal disruption of a low-mass main-sequence star on a parabolic orbit around a massive black hole (Mh = 10 to the 6th stellar mass). The postdisruption evolution is followed until hydrodynamic forces becomes negligible and the liberated gas becomes ballistic. Also given is the rate at which bound mass returns to pericenter after orbiting the hole once. The processes that determine the time scale to circularize the debris orbits and allow an accretion torus to form are discussed. This time scale and the time scales for radiative cooling and accretion inflow determine the onset and duration of the subsequent flare in the AGN luminosity.
[A review on the urban green space cooling effect based on field measurement of air temperature].
Liu, Feng Feng; Yan, Wei Jiao; Kong, Fan Hua; Yin, Hai Wei; Ban, Yu Long; Xu, Wen Bin
2017-04-18
With the development of urbanization, the effect of urban heat island has become increasingly evident. As an essential component of the urban natural landscapes, urban green space plays an important role in mitigating the effect of urban heat island. However, facing the rapid urbanization and changing environment, how to rationally plan and design the green space and realize its best cooling effect which can improve the urban environment and microclimate is still an urgent problem to be solved. So there is a strong need for mulitiscale researches on the cooling effect of urban green space. This paper systematically gave a review on the cooling effect of urban green space based on field measurement of air temperature, the main factors that influenced the cooling effect of green space were explored from three aspects including the area and shape characteristics of urban green space, the structure characteristics of vegetation and the external factors which affected the cooling effect, and the characteristics of the cooling effect of the green space were summarized from the aspect of time variation and distance decay. Then, the main problems and future research prospects of urban green space cooling effect were put forward.
Cunningham, K.J.; Collins, Luke S.
2002-01-01
Upwelling of cool seawater, paleoceanographic circulation, paleoclimate, local tectonics and relative sea-level change controlled the lithofacies and sequence stratigraphy of a carbonate ramp and overlying platform that are part of a temporally well constrained carbonate complex in the Melilla basin, northeastern Morocco. At Melilla, from oldest to youngest, a third-order depositional sequence within the carbonate complex contains (1) a retrogradational, transgressive, warm temperate-type rhodalgal ramp; (2) an early highstand, progradational, bioclastic platform composed mainly of a temperate-type, bivalve-rich molechfor facies; and (3) late highstand, progradational to downstepping, subtropical/tropical-type chlorozoan fringing Porites reefs. The change from rhodalgal ramp to molechfor platform occurred at 7.0??0.14 Ma near the Tortonian/Messinian boundary. During a late stage in the development of the bioclastic platform a transition from temperate-type molechfor facies to subtropical/tropical-type chlorozoan facies occurred and is bracketed by chron 3An.2n (??? 6.3-6.6 Ma). Comparison to a well-dated carbonate complex in southeastern Spain at Cabo de Gata suggests that upwelling of cool seawater influenced production of temperate-type limestone within the ramp and platform at Melilla during postulated late Tortonian-early Messinian subtropical/tropical paleoclimatic conditions in the western Paleo-Mediterranean region. The upwelling of cool seawater across the bioclastic platform at Melilla could be related to the beginning of 'siphoning' of deep, cold Atlantic waters into the Paleo-Mediterranean Sea at 7.17 Ma. The facies change within the bioclastic platform from molechfor to chlorozoan facies may be coincident with a reduction of the siphoning of Atlantic waters and the end of upwelling at Melilla during chron 3An.2n. The ramp contains one retrogradational parasequence and the bioclastic platform three progradational parasequences. Minor erosional surfaces that bound the upper surface of the ramp and upper surface of the oldest platform parasequence are related to relative falls in sea level induced by local volcanism and associated tectonic uplift. These local relative falls had little influence on a broader-scale rise to stillstand in relative sea level that controlled development of the transgressive and early highstand systems tracts represented in the ramp and platform, respectively. ?? 2002 Elsevier Science B.V. All rights reserved.
Pretorius, Thea; Lix, Lisa; Giesbrecht, Gordon
2011-03-01
Previous studies showed that core cooling rates are similar when only the head or only the body is cooled. Structural equation modeling was used on data from two cold water studies involving body-only, or whole body (including head) cooling. Exposure of both the body and head increased core cooling, while only body cooling elicited shivering. Body fat attenuates shivering and core cooling. It is postulated that this protection occurs mainly during body cooling where fat acts as insulation against cold. This explains why head cooling increases surface heat loss with only 11% while increasing core cooling by 39%. Copyright © 2011 Elsevier Ltd. All rights reserved.
Cool transition region loops observed by the Interface Region Imaging Spectrograph
NASA Astrophysics Data System (ADS)
Huang, Z.; Xia, L.; Li, B.; Madjarska, M. S.
2015-12-01
An important class of loops in the solar atmosphere, cool transition region loops, have received little attention mainly due to instrumental limitations. We analyze a cluster of these loops in the on-disk active region NOAA 11934 recorded in a Si IV 1402.8 Å spectral raster and 1400Å slit-jaw (SJ) images taken by the Interface Region Imaging Spectrograph. We divide these loops into three groups and study their dynamics, evolution and interaction.The first group comprises geometrically relatively stable loops, which are finely scaled with 382~626 km cross-sections. Siphon flows in these loops are suggested by the Doppler velocities gradually changing from -10 km/s (blue-shifts) in one end to 20 km/s (red-shifts) in the other. Nonthermal velocities from 15 to 25 km/s were determined. The obtained physical properties suggest that these loops are impulsively heated by magnetic reconnection occurring at the blue-shifted footpoints where magnetic cancellation with a rate of 1015 Mx/s is found. The released magnetic energy is redistributed by the siphon flows. The second group corresponds to two active footpoints rooted in mixed-magnetic-polarity regions. Magnetic reconnection in both footpoints is suggested by explosive-event line profiles with enhanced wings up to 200 km/s and magnetic cancellation with a rate of ~1015 Mx/s. In the third group, an interaction between two cool loop systems is observed. Mixed-magnetic polarities are seen in their conjunction area where explosive-event line profiles and magnetic cancellation with a rate of 3×1015 Mx/s are found. This is a clear indication that magnetic reconnection occurs between these two loop systems. Our observations suggest that the cool transition region loops are heated impulsively most likely by sequences of magnetic reconnection events.
Engelhart, Steffen; Pleischl, Stefan; Lück, Christian; Marklein, Günter; Fischnaller, Edith; Martin, Sybille; Simon, Arne; Exner, Martin
2008-07-01
A case of hospital-acquired legionellosis occurred in a 75-year-old male patient who underwent surgery due to malignant melanoma. Legionellosis was proven by culture of Legionella pneumophila serogroup 1 from bronchoalveolar lavage (BAL) fluid. Being a chronic smoker the patient used to visit the sickroom balcony that was located about 90 m to the west of a hospital cooling tower. Routine cooling tower water samples drawn during the presumed incubation period revealed 1.0x10(4) CFU/100 ml (L. pneumophila serogroup 1). One of three isolates from the cooling tower water matched the patient's isolate by monoclonal antibody (mab)- and genotyping (sequence-based typing). Horizontal transport of cooling tower aerosols probably was favoured by meteorological conditions with thermal inversion. The case report stresses the importance of routine maintenance and microbiological control of hospital cooling towers.
Analysis and comparison of wall cooling schemes for advanced gas turbine applications
NASA Technical Reports Server (NTRS)
Colladay, R. S.
1972-01-01
The relative performance of (1) counterflow film cooling, (2) parallel-flow film cooling, (3) convection cooling, (4) adiabatic film cooling, (5) transpiration cooling, and (6) full-coverage film cooling was investigated for heat loading conditions expected in future gas turbine engines. Assumed in the analysis were hot-gas conditions of 2200 K (3500 F) recovery temperature, 5 to 40 atmospheres total pressure, and 0.6 gas Mach number and a cooling air supply temperature of 811 K (1000 F). The first three cooling methods involve film cooling from slots. Counterflow and parallel flow describe the direction of convection cooling air along the inside surface of the wall relative to the main gas flow direction. The importance of utilizing the heat sink available in the coolant for convection cooling prior to film injection is illustrated.
USDA-ARS?s Scientific Manuscript database
Grazing of cool-season grasses by beef calves before entry into the feedlot for finishing is an important component of the US beef production system. The length of time in the feedlot and the quantity of feed grain required to reach market BW would be reduced if more BW was gained during the grazing...
NASA Astrophysics Data System (ADS)
Fosdick, Julie C.; Carrapa, Barbara; Ortíz, Gustavo
2015-12-01
The Argentine Precordillera is an archetypal retroarc fold-and-thrust belt that records tectonics associated with changing subduction regimes. The interactions between exhumation and faulting in the Precordillera were investigated using apatite and zircon (U-Th-Sm)/He and apatite fission track thermochronometry from the Precordillera and adjacent geologic domains. Inverse modeling of thermal histories constrains eastward in-sequence rock cooling associated with deformation and erosion from 18 to 2 Ma across the Central Precordillera tracking thrusting during this time. The youngest AHe ages (5-2 Ma) and highest erosion rates are located in the eastern and western extremities of the Precordillera and indicate that recent denudation is concentrated at its structural boundaries. Moreover, synchronous rapid Pliocene cooling of the Frontal Cordillera, Eastern Precordillera, and Sierra del Valle Fértil was coeval with initiation of basement-involved faulting in the foreland. Detrital zircon U-Pb geochronology from the ca. 16-8.1 Ma Bermejo foreland basin strata suggests fluvial connectivity westward beyond the Frontal Cordillera to the Main Cordillera and Coast Range followed by an important shift in sediment provenance at ca. 10 Ma. At this time, we suggest that a substantial decrease in Permo-Triassic igneous sources in the Frontal Cordillera and concurrent increase in recycled zircons signatures of Paleozoic strata are best explained by uplift and erosion of the Precordillera during widening of the thrust-belt. Bedrock thermochronology and modeling indicate a 2-6 Myr lag time between faulting-related cooling in the hinterland and the detrital record of deformation in the foreland basin, suggesting that for tectonically active semi-arid settings, bedrock cooling may be more sensitive to onset of faulting. We suggest that high erosion rates in the Frontal Cordillera and Eastern Precordillera are associated with increased interplate coupling during shallowing of the subducting Nazca plate that may concentrate stress along weak structural boundaries of the Precordillera.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lan, Liangyun, E-mail: lanly@me.neu.edu.cn; State Key Laboratory of Rolling Technology and Automation, Northeastern University, Shenyang 110819; Kong, Xiangwei
2015-07-15
Coarse austenite to bainite transformation in low carbon steel under simulated welding thermal cycles was morphologically and crystallographically characterized by means of optical microscope, transmission electron microscope and electron backscattered diffraction technology. The results showed that the main microstructure changes from a mixture of lath martensite and bainitic ferrite to granular bainite with the increase in cooling time. The width of bainitic laths also increases gradually with the cooling time. For a welding thermal cycle with relatively short cooling time (e.g. t{sub 8/5} is 30 s), the main mode of variant grouping at the scale of individual prior austenite grainsmore » changes from Bain grouping to close-packed plane grouping with the progress of phase transformation, which results in inhomogeneous distribution of high angle boundaries. As the cooling time is increased, the Bain grouping of variants becomes predominant mode, which enlarges the effective grain size of product phase. - Highlights: • Main microstructure changes and the width of lath structure increases with cooling time. • Variant grouping changes from Bain zone to close-packed plane grouping with the transformation. • The change of variant grouping results in uneven distribution of high angle grain boundary. • Bain grouping is main mode for large heat input, which lowers the density of high angle boundary.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Curry, J J; Gallagher, D W; Modarres, M
Appendices are presented concerning isolation condenser makeup; vapor suppression system; station air system; reactor building closed cooling water system; turbine building secondary closed water system; service water system; emergency service water system; fire protection system; emergency ac power; dc power system; event probability estimation; methodology of accident sequence quantification; and assignment of dominant sequences to release categories.
NASA Astrophysics Data System (ADS)
Ghoshal, S.; McQuarrie, N.; Robinson, D. M.; Olree, E.; Valentino, C.; Olsen, J.
2017-12-01
Recent field mapping in the Central Himalaya revealed a marked change in the location and orientation of exposed Greater Himalayan rocks around the epicenter of the April 2015 Gorkha earthquake, arguing for a lateral structure in the Main Himalayan Thrust (MHT). The earthquake provided new insight into the geometry of the MHT, but left the position and depth of the mid-crustal ramp in dispute. Combining new field data with existing thermochronometric data from the region emphasizes that both the mapped geology and young cooling ages step abruptly southward from east to west, immediately adjacent to the earthquake epicenter. The distribution of cooling ages is strongly influenced by the location of ramps in the decollement surface, as the vertical component of uplift concentrates exhumation over the ramp, producing the youngest ages there. We propose that the existence and location of frontal and lateral ramps can be evaluated using the regional distribution of thermochronometric ages. Sequentially deformed cross-sections present a model of how structurally induced uplift varies in time and space, as well as a predicted geometry of the active, modern fault. We created new balanced cross-sections, constrained by surface geology and the proposed decollement geometries. For an accurate representation of the subsurface, the geometries must reproduce cooling ages measured at the surface. Each cross section was sequentially deformed, allowing for flexure and erosion. The resulting displacement field was used to predict cooling ages for muscovite 40Ar/39Ar, zircon (U-Th)/He, and apatite fission-track, using the thermokinematic model Pecube. The different closure temperatures for these systems allow them to represent different times and locations of exhumation driven by evolving fault geometries. The modeled cooling ages are the cumulative effect of the entire deformational sequence. However, the ages are particularly sensitive to the modern active decollement fault geometry, allowing us to evaluate the different proposed cross-section geometries, and identify the best match to the regional distribution of cooling ages. We argue that this final geometry is the most accurate representation of the subsurface, being constrained by surface geology, thermochronological ages, and data from the earthquake.
NASA Astrophysics Data System (ADS)
Zhai, Degao; Liu, Jiajun; Cook, Nigel J.; Wang, Xilong; Yang, Yongqiang; Zhang, Anli; Jiao, Yingchun
2018-04-01
The Bianjiadayuan Ag-Pb-Zn deposit (4.81 Mt. @157.4 g/t Ag and 3.94% Pb + Zn) is located in the Great Hinggan Range Pb-Zn-Ag-Cu-Mo-Sn-Fe polymetallic metallogenic belt, NE China. Vein type Pb-Zn-Ag ore bodies are primarily hosted by slate, adjacent to a Sn ± Cu ± Mo mineralized porphyry intrusion. The deposit is characterized by silver-rich ores with Ag grades up to 3000 g/t. Four primary paragenetic sequences are recognized: (I) arsenopyrite + pyrite + quartz, (II) main sulfide + quartz, (III) silver-bearing sulfosalt + quartz, and (IV) boulangerite + calcite. A subsequent supergene oxidation stage has also been identified. Hydrothermal alteration consists of an early episode of silicification, two intermediate episodes (propylitic and phyllic), and a late argillic episode. Silver mineralization primarily belongs to the late paragenetic sequence III. Freibergite is the dominant and most important Ag-mineral in the deposit. Detailed ore mineralogy of Bianjiadayuan freibergite reveals evidence of chemical heterogeneity down to the microscale. Silver-rich sulfosalts in the late paragenetic sequence III are largely derived from a series of retrograde and solid-state reactions that redistribute Ag via decomposition and exsolution during cooling, illustrating that documentation of post-mineralization processes is essential for understanding silver ore formation. Sulfur and lead isotope compositions of sulfides, and comparison with those of local various geological units, indicate that the ore-forming fluids, lead, and other metals have a magmatic origin, suggesting a close genetic association between the studied Ag-Pb-Zn veins and the local granitic intrusion. Fluid cooling coupled with decreases in fO2 and fS2 are the factors inferred to have led to a decrease of silver solubility in the hydrothermal fluid, and successively promoted extensive Ag deposition.
The intermediate-age pre-cataclysmic variables SDSS J172406+562003 and RE J2013+4002
NASA Astrophysics Data System (ADS)
Shimansky, V. V.; Borisov, N. V.; Nurtdinova, D. N.; Mitrofanova, A. A.; Vlasyuk, V. V.; Spiridonova, O. I.
2012-06-01
We have analyzed the physical status of the pre-cataclysmic variables SDSSJ172406+562003 and RE J2013+4002, which have evolved after their common-envelope stage a time t = 106-107 years. Spectroscopy and photometry of these systems were performed with the 6-m and 1-m telescopes of the Special Astrophysical Observatory. We demonstrate that emission lines in the spectra were formed solely by the reflection of radiation emitted by the white dwarfs on the surfaces of their cool companions, under conditions close to local thermodynamic equilibrium. These effects are also responsible for most of the objects' photometric variability amplitude. However, comparing the light curves of SDSS 172406 from different epochs, we find aperiodic brightness variations, probably due to spottedness of the surface of the secondary. Jointly analyzing the spectra, radial-velocity curves, and light curves of the pre-cataclysmic variables and modeling the reflection effects, we have derived their fundamental parameters. We demonstrate that the secondaries in these systems are consistent with evolutionary models for main-sequence stars and do not have the luminosity excesses characteristic of cool stars in young pre-cataclysmic variables.
Simulation of a 20-ton LiBr/H{sub 2}O absorption cooling system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wardono, B.; Nelson, R.M.
The possibility of using solar energy as the main heat input for cooling systems has led to several studies of available cooling technologies that use solar energy. The results show that double-effect absorption cooling systems give relatively high performance. To further study absorption cooling systems, a computer code was developed for a double-effect lithium bromide/water (LiBr/H{sub 2}O) absorption system. To evaluate the performance, two objective functions were developed including the coefficient of performance (COP) and the system cost. Based on the system cost, an optimization to find the minimum cost was performed to determine the nominal heat transfer areas ofmore » each heat exchanger. The nominal values of other system variables, such as the mass flow rates and inlet temperatures of the hot water, cooling water, and chilled water, are specified as commonly used values for commercial machines. The results of the optimization show that there are optimum heat transfer areas. In this study, hot water is used as the main energy input. Using a constant load of 20 tons cooling capacity, the effects of various variables including the heat transfer ares, mass flow rates, and inlet temperatures of hot water, cooling water, and chilled water are presented.« less
Qin, Lei; Bi, Jing-Ran; Li, Dong-Mei; Dong, Meng; Zhao, Zi-Yuan; Dong, Xiu-Ping; Zhou, Da-Yong; Zhu, Bei-Wei
2016-11-16
We aimed to explore the differences of thermal behaviors between insoluble collagen fibrils (ICFs) and pepsin-solubilized collagens (PSCs) from sea cucumber Stichopus japonicus . The unfolding/refolding sequences of secondary structures of ICFs and PSCs during the heating and cooling cycle (5 → 70 → 5 °C) were identified by Fourier transform infrared spectrometry combined with curve-fitting and 2D correlation techniques. ICFs showed a higher proportion of α-helical structures and higher thermostability than PSCs, and thus had more-stable triple helical structures. The sequences of changes affecting the secondary structures during heating were essentially the same between ICFs and PSCs. In all cases, α-helix structure was the most important conformation and it disappeared to form a β-sheet structure. In the cooling cycle, ICFs showed a partially refolding ability, and the proportion of β-sheet structure rose before the increasing proportion of α-helix structure. PSCs did not obviously refold during the cooling stage.
Variable X-ray Emission from FU Orionis
NASA Astrophysics Data System (ADS)
Skinner, Steve L.; Guedel, M.; Briggs, K. R.; Lamzin, S. A.; Sokal, K. R.
2009-05-01
FU Orionis is the prototype of a small but remarkable class of pre-main sequence stars ('FUors') that have undergone large optical outbursts thought to be linked to episodic accretion. FU Ori increased in optical brightness by about 6 mag in 1936-37 and is still in slow decline. Because of their high accretion rates, FUors are good candidates for exploring potential effects of accretion on X-ray emission. A recently completed survey of FUors with XMM-Newton detected X-rays from FU Ori and V1735 Cyg. We present new results from a sensitive 99 ksec (1.15 day) follow-up X-ray observation of FU Ori with Chandra. The Chandra ACIS-S CCD spectrum confirms the presence of a cool plasma component (kT < 1 keV) viewed under moderate absorption and a much hotter component (kT > 3 keV), viewed under high absorption, in accord with previous XMM results. The uninterrupted Chandra light curve shows that the hot component is slowly variable on a timescale of one day, but no variability is detected in the cool component. The slow variability and high plasma temperature point to a magnetic origin for the hot component, but other mechanisms (including accretion) may be responsible for the cool non-variable component. We will discuss these new results in the context of what is known about FU Ori from previous observations, including XMM (Skinner et al. 2006, ApJ, 643, 995) and HST (Kravtsova et al. 2007, Ast. Ltrs., 33, 755).
Population Synthesis Studies of the White Dwarfs of the Galactic Disk and Halo
NASA Astrophysics Data System (ADS)
Cojocaru, Elena-Ruxandra
2016-09-01
White dwarfs are fossil stars that can encode valuable information about the formation, evolution and other properties of the different Galactic stellar populations. They are the direct descendants of main-sequence stars with masses ranging from ∼0.8 M⊙ to ∼10 M⊙, which means that over 95% of the stars in our Galaxy will eventually become white dwarfs. This fact, correlated with the excellent quality of modern white dwarf cooling models, clearly marks their potential as cosmic clocks for estimating the ages of Galactic stellar populations, as well as place white dwarfs as privileged objects in understanding several actual astrophysical problems. Stellar population synthesis methods (Tinsley, 1968) use theoretical evolutionary sequences to reproduce luminosities, temperatures and other parameters building up to a synthetic population that can be readily compared to an observed sample of stars. Such techniques are perfect for the study of the different white dwarf populations in our Galaxy and their strength has only grown in recent years, fueled both by improved evolutionary sequences and detailed cooling tracks and also by the ever growing samples of white dwarfs identified through modern survey missions. In particular, the work presented in this thesis uses an updated population synthesis code based on previous versions of the code from our group (García-Berro et al., 1999; Torres et al., 2002; García-Berro et al., 2004; Torres et al., 2005; Camacho et al., 2014). Our synthetic population code, based on Monte Carlo statistical techniques, has been extensively used in the study of the disk (García-Berro et al., 1! 999; Torres et al., 2001; Torres & García-Berro, 2016) and halo (Torres et al., 2002; García-Berro et al., 2004) single white-dwarf population, white dwarf plus main sequence stars (Camacho et al., 2014), as well as open clusters such as NGC 6791 (García-Berro et al., 2010; García-Berro et al., 2011) or globular clusters, as 47 Tuc (García-Berro et al., 2014). In this thesis we investigate different properties of single and binary white dwarf populations in the Galactic disk and halo. We first study the effect of progenitor metallicity on the thin disk white dwarf luminosity function. Stellar metallicity is an important parameter in computing both main-sequence evolutionary sequences and white dwarf cooling tracks. At the same, studies of the metallicity distribution function for the Galactic disk have shown that both high and low-metallicity stars can be found throughout the entire mass range, although a clear dependence between age and metallicity has yet to be proven and more recent findings actually show little correlation. With this in mind, we test two different age-metallicity relations, one assuming a Gaussian distribution of metallicity around the Solar value, the other one a decreasing relation between age and metallicity. We take into account the influence of metallicity on both main sequence lifetimes and white dwarf s! tellar parameters. Finally, we compute the theoretical white dwarf luminosity function applying the observational selection criteria of two different surveys, the Sloan Digital Sky Survey (SDSS) and the Supercosmos Sky Survey (SSS). Next, we compute the white dwarf luminosity, mass and cumulative age functions derived from a sample of DA white dwarfs obtained from the LAMOST Spectroscopic Survey of the Galactic anti-center (LSS-GAC). We also derive the local space density and the formation rate for DA white dwarf. Given that both the observed mass distribution obtained from this sample and that derived from the local sample of white dwarfs present an apparent excess of massive white dwarfs, we investigate the possibility of accounting for this excess by reproducing the white dwarf population of the thin disk under different sets of initial assumptions, accounting also for selection criteria and observational biases. Another issue that we investigate is the robustness of the halo white dwarf luminosity function employing different models for the initial mass function, density profile and stellar formation history. We also analyze if the white dwarf luminosity function can be used as a means to discriminate the role played by residual hydrogen burning in the atmospheres of low-mass white dwarfs. This process is known to become a significant source of energy for white dwarfs descending from very low metallicity progenitors, such as those that characterize the Galactic halo population. Lastly, we simulate the white dwarf-main sequence (WD+MS) binary population of the Galactic disk and compare it to the parameter distributions from the largest and most recent WD+MS catalog derived from the SDSS (Rebassa-Mansergas et al., 2016b). We not only reproduce the selection criteria, but we also account for spectroscopic completeness, observational errors and other biases that affect the sample. We use the observed population as a benchmark for constraining several important physical quantities specific to binary evolution, such as the initial mass ratio distribution and also the common envelope parametrization. This thesis is based on three published papers, Cojocaru et al. (2014), Rebassa-Mansergas et al. (2015) and Cojocaru et al. (2015) and another work in preparation.
NASA Astrophysics Data System (ADS)
Coşar, Gökhan; Pooyanfar, Mirparham; Amirabedin, Ehsan; Topal, Hüseyin
2013-12-01
Recovering energy from municipal solid waste (MSW) is one of the most important issues of energy management in developed countries. This raises even more interest as world fossil fuel reserves diminish and fuel prices rise. Being one of main processes of waste disposal, anaerobic digestion can be used as a means to reduce fossil fuel and electricity consumption as well as reducing emissions. With growing demand for cooling in Turkey, especially during warm seasons and considering the energy costs, utilizing heat-driven absorption cooling systems coupled with an anaerobic digester for local cooling purposes is a potentially interesting alternative for electricity driven compression cooling. The aim of this article is to study the viability of utilizing biogas obtained from MSW anaerobic digestion as the main fuel for heating facilities of Gazi University, Turkey and also the energy source for an absorption cooling system designed for the central library of the aforementioned campus. The results prove that the suggested system is sustainably and financially appealing and has the potential to replace the conventional electricity driven cooling systems with a reasonable net present worth; moreover, it can notably reduce carbon dioxide emissions.
Guo, Yan; Zhang, Jinliang; Yan, Yongfeng; Wu, Jian; Zhu, Nengwu; Deng, Changyan
2015-01-01
Polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) and subsequent sub-cloning and sequencing were used in this study to analyze the molecular phylogenetic diversity and spatial distribution of bacterial communities in different spatial locations during the cooling stage of composted swine manure. Total microbial DNA was extracted, and bacterial near full-length 16S rRNA genes were subsequently amplified, cloned, RFLP-screened, and sequenced. A total of 420 positive clones were classified by RFLP and near-full-length 16S rDNA sequences. Approximately 48 operational taxonomic units (OTUs) were found among 139 positive clones from the superstratum sample; 26 among 149 were from the middle-level sample and 35 among 132 were from the substrate sample. Thermobifida fusca was common in the superstratum layer of the pile. Some Bacillus spp. were remarkable in the middle-level layer, and Clostridium sp. was dominant in the substrate layer. Among 109 OTUs, 99 displayed homology with those in the GenBank database. Ten OTUs were not closely related to any known species. The superstratum sample had the highest microbial diversity, and different and distinct bacterial communities were detected in the three different layers. This study demonstrated the spatial characteristics of the microbial community distribution in the cooling stage of swine manure compost. PMID:25925066
Quinn, Celia; Demirjian, Alicia; Watkins, Louise Francois; Tomczyk, Sara; Lucas, Claressa; Brown, Ellen; Kozak-Muiznieks, Natalia; Benitez, Alvaro; Garrison, Laurel E; Kunz, Jasen; Brewer, Scott; Eitniear, Samantha; DiOrio, Mary
2015-12-01
On July 9, 2013, an outbreak of Legionnaires' disease (LD) was identified at Long-Term Care Facility A in central Ohio. This article describes the investigation of the outbreak and identification of the outbreak source, a cooling tower using an automated biocide delivery system. In total, 39 outbreak LD cases were identified; among these, six patients died. Water samples from a cooling tower were positive for Legionella pneumophila serogroup 1, reactive to monoclonal antibody 2, with matching sequence type to a patient isolate. An electronic control system turned off cooling tower pumps during low-demand periods, preventing delivery of disinfectant by a timed-release system, and leading to amplification of Legionella in the cooling tower. Guidelines for tower maintenance should address optimal disinfection when using automated systems.
Film Cooling Flow Effects on Post-Combustor Trace Chemistry
NASA Technical Reports Server (NTRS)
Wey, Thomas; Liu, Nan-Suey
2003-01-01
Film cooling injection is widely applied in the thermal design of turbomachinery, as it contributes to achieve higher operating temperature conditions of modern gas turbines, and to meet the requirements for reliability and life cycles. It is a significant part of the high-pressure turbine system. The film cooling injection, however, interacts with the main flow and is susceptible to have an influence on the aerodynamic performance of the cooled components, and through that may cause a penalty on the overall efficiency of the gas turbine. The main reasons are the loss of total pressure resulting from mixing the cooling air with mainstream and the reduction of the gas stagnation temperature at the exit of the combustion chamber to a lower value at the exit of nozzle guide vane. In addition, the impact of the injected air on the evolution of the trace species of the hot gas is not yet quite clear. This work computationally investigates the film cooling influence on post-combustor trace chemistry, as trace species in aircraft exhaust affect climate and ozone.
ABSOLUTE PROPERTIES OF THE HIGHLY ECCENTRIC, SOLAR-TYPE ECLIPSING BINARY HD 74057
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sowell, James R.; Henry, Gregory W.; Fekel, Francis C., E-mail: jim.sowell@physics.gatech.edu, E-mail: gregory.w.henry@gmail.com, E-mail: fekel@evans.tsuniv.edu
2012-01-15
We have obtained Stroemgren b and y differential photometric observations of the solar-type eclipsing binary HD 74057 plus follow-up high-resolution, red wavelength spectroscopic observations. The system has an orbital period of 31.2198 days, a high eccentricity of 0.47, and is seen almost exactly edge on with an inclination of 89.{sup 0}8. The two main-sequence G0 stars are nearly identical in all physical characteristics. We used the Wilson-Devinney program to obtain a simultaneous solution of our photometric and spectroscopic observations. The resulting masses of the components are M{sub 1} = 1.138 {+-} 0.003 M{sub Sun} and M{sub 2} = 1.131 {+-}more » 0.003 M{sub Sun }, and the radii are R{sub 1} = 1.064 {+-} 0.002 R{sub Sun} and R{sub 2} = 1.049 {+-} 0.002 R{sub Sun }. The effective temperatures are 5900 K (fixed) and 5843 K, and the iron abundance, [Fe/H], is estimated to be +0.07. A comparison with evolutionary tracks suggests that the system may be even more metal rich. The components rotate with periods of 8.4 days, significantly faster than the predicted pseudosynchronous period of 12.7 days. We see evidence that one or both components have cool spots. Both stars are close to the zero-age main sequence and are about 1.0 Gyr old.« less
NASA Astrophysics Data System (ADS)
Baliunas, S. L.
2004-05-01
Is hope for understanding the solar magnetic cycle to be found in stars? Observations of stars with significant sub-surface convective zones -- masses smaller than about 1.5 solar masses on the lower main sequence and many types of cool, post-main-sequence stars -- indicate the presence of surface and atmospheric inhomogeneities analogous to solar magnetic features, making stellar magnetic activity a cosmically widespread phenomenon. Observations have been made primarily in visible wavelengths, and important information has also been derived from the ultraviolet and x-ray spectrum regions. Interannual to interdecadal variability of spectrum indicators of stellar magnetic features is common, and in some cases similar in appearance to the 11-year sunspot cycle. Successful models of the physical processes responsible for stellar magnetic cycles, typically cast as a magnetohydrodynamic dynamo, require advances in understanding not only convection but also the magnetic field's interaction with it. The observed facts that underpin the hope for models will be summarized. Properties of stellar magnetic cycles will be compared and contrasted with those of the sun, including inferences from paleo-environmental reservoirs that contain information on solar century- to millennial-scale magnetic variability. Partial support of this research came from NASA NAG5-7635, NRC COBASE, CRDF 322, MIT-MSG 5710001241, JPL 1236821, AF 49620-02-1-0194, Richard Lounsberry Foundation, Langley-Abbot, Rollins, Scholarly Studies and James Arthur Funds (Smithsonian Institution) and several generous individuals.
Analysis of fundamental parameters for V477 Lyr
NASA Astrophysics Data System (ADS)
Shimansky, V. V.; Pozdnyakova, S. A.; Borisov, N. V.; Bikmaev, I. F.; Galeev, A. I.; Sakhibullin, N. A.; Spiridonova, O. I.
2008-06-01
We analyze the photometric and spectroscopic observations of the young pre-cataclysmic variable (pre-CV) V477 Lyr. The masses of both binary components have been corrected by analyzing their radial velocity curves. We show that agreement between the theoretical and observed light curves of the object is possible for several sets of its physical parameters corresponding to the chosen temperature of the primary component. The final parameters of V477 Lyr have been established by comparing observational data with evolutionary tracks for planetary nebula nuclei. The derived effective temperature of the O subdwarf is higher than that estimated by analyzing the object’s ultraviolet spectra by more than 10000 K. This is in agreement with the analogous results obtained previously for the young pre-CVs V664 Cas and UU Sge. The secondary component of V477 Lyr has been proven to have a more than 25-fold luminosity excess compared to main-sequence stars of similar mass. Comparison of the physical parameters for the cool stars in young pre-CVs indicates that their luminosities do not correlate with the masses of the objects. The observed luminosity excesses in such stars show a close correlation with the post-common-envelope lifetime of the systems and should be investigated within the framework of the theory of their relaxation to the state of main-sequence stars.
On the Accuracy of Atmospheric Parameter Determination in BAFGK Stars
NASA Astrophysics Data System (ADS)
Ryabchikova, T.; Piskunov, N.; Shulyak, D.
2015-04-01
During the past few years, many papers determining the atmospheric parameters in FGK stars appeared in the literature where the accuracy of effective temperatures is given as 20-40 K. For main sequence stars within the 5 000-13 000 K temperature range, we have performed a comparative analysis of the parameters derived from the spectra by using the SME (Spectroscopy Made Easy) package and those found in the literature. Our sample includes standard stars Sirius, Procyon, δ Eri, and the Sun. Combining different spectral regions in the fitting procedure, we investigated an effect different atomic species have on the derived atmospheric parameters. The temperature difference may exceed 100 K depending on the spectral regions used in the SME procedure. It is shown that the atmospheric parameters derived with the SME procedure which includes wings of hydrogen lines in fitting agrees better with the results derived by the other methods and tools across a large part of the main sequence. For three stars—π Cet, 21 Peg, and Procyon—the atmospheric parameters were also derived by fitting a calculated energy distribution to the observed one. We found a substantial difference in the parameters inferred from different sets and combinations of spectrophotometric observations. An intercomparison of our results and literature data shows that the average accuracy of effective temperature determination for cool stars and for the early B-stars is 70-85 K and 170-200 K, respectively.
NASA Technical Reports Server (NTRS)
Kirkpatrick, J. Davy; Mcgraw, John T.; Hess, Thomas R.; Liebert, James; Mccarthy, Donald W., Jr.
1994-01-01
The luminosity function at the end of the main sequence is determined from V, R, and I data taken by the charge coupled devices (CCD)/Transit Instrument, a dedicated telescope surveying an 8.25 min wide strip of sky centered at delta = +28 deg, thus sampling Galactic latitudes of +90 deg down to -35 deg. A selection of 133 objects chosen via R - I and V - I colors has been observed spectroscopically at the 4.5 m Multiple Mirror Telescope to assess contributions by giants and subdwarfs and to verify that the reddest targets are objects of extremely late spectral class. Eighteen dwarfs of type M6 or later have been discovered, with the latest being of type M8.5. Data used for the determination of the luminosity function cover 27.3 sq. deg down to a completeness limit of R = 19.0. This luminosity function, computed at V, I, and bolometric magnitudes, shows an increase at the lowest luminosities, corresponding to spectral types later than M6- an effect suggested in earlier work by Reid & Gilmore and Legget & Hawkins. When the luminosity function is segregated into north Galactic and south Galactic portions, it is found that the upturn at faint magnitudes exists only in the southern sample. In fact, no dwarfs with M(sub I) is greater than or equal to 12.0 are found within the limiting volume of the 19.4 sq deg northern sample, in stark contrast to the smaller 7.9 sq deg area at southerly latitudes where seven such dwarfs are found. This fact, combined with the fact that the Sun is located approximately 10-40 pc north of the midplane, suggests that the latest dwarfs are part of a young population with a scale height much smaller than the 350 pc value generally adopted for other M dwarfs. These objects comprise a young population either because the lower metallicities prevelant at earlier epochs inhibited the formation of late M dwarfs or because the older counterparts of this population have cooled beyond current detection limits. The latter scenario would hold if these late-type M dwarfs are substellar. The luminosity function data together with an empirical derivation of the mass-luminosity relation (from Henry & McCarthy) are used to compute a mass function independent of theory. This mass function increases toward the end of the main sequence, but the observed density of M dwarfs is still insufficient to account for the missing mass. If the increases seen in the luminosity and mass functions are indicative of a large, unseen, substellar population, brown dwarfs may yet add significantly to the mass of the Galaxy.
Multifrequency observations of symbiotic stars
NASA Technical Reports Server (NTRS)
Kenyon, Scott J.
1988-01-01
The discovery of symbiotic stars is described, and the results of multifrequency observations made during the past two decades are presented. Observational data identify symbiotic stars as long-period binary systems that can be divided into two basic physical classes: detached symbiotics containing a red giant (or a Mira variable), and semidetached symbiotics containing a lobe-filling red giant and a solar-type main sequence star. Three components are typically observed: (1) the cool giant component with an effective temperature of 2500-4000 K, which can be divided by the IR spectral classification into normal M giants (S-types) and heavily reddened Mira variables (D-types); (2) the hot companion displaying a bright blue continuum at UV wavelengths, which is sometimes also an X-ray source; and (3) a gaseous nebula enveloping the binary.
Cool Companions of White Dwarfs from 2MASS
NASA Astrophysics Data System (ADS)
Hoard, D. W.; Wachter, S.; Sturch, L. K.; Widhalm, A. M.; Weiler, K. P.; Wellhouse, J. W.; Gibiansky, M.
2006-12-01
Detecting low mass stellar companions to white dwarfs (WDs) offers many advantages compared to main sequence primaries. In the latter case, faint low mass companions are often hidden in the glare of the more luminous main sequence primary, and radial velocity variations are small and, therefore, difficult to detect. Since WDs are less luminous than main sequence stars, the brightness contrast compared to a potential faint companion is significantly reduced. Most importantly, the markedly different spectral energy distributions of the WDs and their low mass companions makes the detection and separation of the two components relatively straightforward even with simple broad-band multi-color photometry. We have shown in Wachter et al. (2003) that the 2MASS near-IR color-color diagram can easily and efficiently identify candidates for unresolved WD + red dwarf binaries. Our follow-up observations (e.g., Farihi et al. 2006) have shown that a large fraction of these candidates are confirmed as previously unknown binary stars. Here, we present results from our full survey of the 2235 WDs from the McCook & Sion (1999) Catalog using the 2MASS All-Sky Data Release. We have identified an additional large sample of candidate WD + red dwarf binaries, as well as a number of systems that may contain extremely low mass stellar or substellar companions. Support for this work was provided by the National Aeronautics and Space Administration (NASA) under an Astrophysics Data Program grant issued through the Office of Space Science. This research made use of the NASA/Infrared Processing and Analysis Center (IPAC) Infrared Science Archive, which is operated by the Jet Propulsion Laboratory/California Institute of Technology (CIT), under contract with NASA, and data products from the Two Micron All Sky Survey, which is a joint project of the University of Massachusetts and IPAC/CIT, funded by NASA and the National Science Foundation.
Thinking of biology: asteroid impacts, microbes, and the cooling of the atmosphere
NASA Technical Reports Server (NTRS)
Oberbeck, V. R.; Mancinelli, R. L.
1994-01-01
The authors examine the cooling of the Earth's surface from 3.75 to 1 billion years ago. Three effects of the bombardment of Earth by asteroids and comets that may have delayed surface cooling include time to form continents, volatilization of carbonate rocks which released carbon dioxide into the atmosphere, and inability of microbes to inhabit land masses during large impact events. Continental microbes may have helped reduce high temperatures from 3.75 to 3.5 billion years ago. If so, the evolutionary sequence of microbes is proposed to be anaerobic heterotrophs, chemoautotrophs, and then photoautotrophs.
The Cool White Dwarf Luminosity Function and the Age of the Galactic Disk
NASA Astrophysics Data System (ADS)
Leggett, S. K.; Ruiz, Maria Teresa; Bergeron, P.
1998-04-01
We present new optical and infrared data for the cool white dwarfs in the proper motion sample of Liebert, Dahn, & Monet. Stellar properties--surface chemical composition, effective temperature, radius, surface gravity, mass, and luminosity--are determined from these data by using the model atmospheres of Bergeron, Saumon, & Wesemael. The space density contribution is calculated for each star and the luminosity function (LF) for cool white dwarfs is determined. Comparing the LF to the most recent cooling sequences by Wood implies that the age of the local region of the Galactic disk is 8 +/- 1.5 Gyr. This result is consistent with the younger ages now being derived for the globular clusters and the universe itself.
Film cooling: case of double rows of staggered jets.
Dorignac, E; Vullierme, J J; Noirault, P; Foucault, E; Bousgarbiès, J L
2001-05-01
An experimental investigation of film cooling of a wall in a case of double rows of staggered hot jets (65 degrees C) in an ambient air flow. The wall is heated at a temperature value between the one of the jets and the one of the main flow. Experiments have been carried out for different injection rates, the main flow velocity is maintained at 32 m/s. Association of the measures of temperature profiles by cold wire and the measures of wall temperature by infrared thermography allows us to describe the behaviour of the flows and to propose the best injection which assures a good cooling of the plate.
General view looking down the approximate centerline of the expansion ...
General view looking down the approximate centerline of the expansion nozzle of a Space Shuttle Main Engine (SSME) mounted on a SSME Engine Handler in the SSME Processing Facility at Kennedy Space Center. This view shows the 1080 cooling tubes used to regeneratively cool the Nozzle and Combustion Chamber by circulating relatively low temperature fuel through the tubes and manifolds before being ignited in the Main Combustion Chamber. - Space Transportation System, Space Shuttle Main Engine, Lyndon B. Johnson Space Center, 2101 NASA Parkway, Houston, Harris County, TX
Engine management during NTRE start up
NASA Technical Reports Server (NTRS)
Bulman, Mel; Saltzman, Dave
1993-01-01
The topics are presented in viewgraph form and include the following: total engine system management critical to successful nuclear thermal rocket engine (NTRE) start up; NERVA type engine start windows; reactor power control; heterogeneous reactor cooling; propellant feed system dynamics; integrated NTRE start sequence; moderator cooling loop and efficient NTRE starting; analytical simulation and low risk engine development; accurate simulation through dynamic coupling of physical processes; and integrated NTRE and mission performance.
Optimization of Turbine Rim Seals
NASA Technical Reports Server (NTRS)
Wagner, J. H.; Tew, D. E.; Stetson, G. M.; Sabnis, J. S.
2006-01-01
Experiments are being conducted to gain an understanding of the physics of rim scale cavity ingestion in a turbine stage with the high-work, single-stage characteristics envisioned for Advanced Subsonic Transport (AST) aircraft gas turbine engines fo the early 21st century. Initial experimental measurements to be presented include time-averaged turbine rim cavity and main gas path static pressure measurements for rim seal coolant to main gas path mass flow ratios between 0 and 0.02. The ultimate objective of this work is develop improved rim seal design concepts for use in modern high-work, single sage turbines n order to minimize the use of secondary coolant flow. Toward this objective the time averaged and unsteady data to be obtained in these experiments will be used to 1) Quantify the impact of the rim cavity cooling air on the ingestion process. 2) Quantify the film cooling benefits of the rim cavity purge flow in the main gas path. 3) Quantify the impact of the cooling air on turbine efficiency. 4) Develop/evaluate both 3D CFD and analytical models of the ingestion/cooling process.
NASA Astrophysics Data System (ADS)
Nemec, Patrik; Malcho, Milan
2018-06-01
This work deal with experimental measurement and calculation cooling efficiency of the cooling device working with a heat pipe technology. The referred device in the article is cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description, working principle and construction of cooling device. The main factor affected the dissipation of high heat flux from electronic elements through the cooling device to the surrounding is condenser construction, its capacity and option of heat removal. Experimental part describe the measuring method cooling efficiency of the cooling device depending on ambient temperature in range -20 to 40°C and at heat load of electronic components 750 W. Measured results are compared with results calculation based on physical phenomena of boiling, condensation and natural convection heat transfer.
Syed, Mudasir Ahmad; Bhat, Farooz Ahmad; Balkhi, Masood-ul Hassan; Bhat, Bilal Ahmad
2016-01-01
Schizothoracine fish commonly called snow trouts inhibit the entire network of snow and spring fed cool waters of Kashmir, India. Over 10 species reported earlier, only five species have been found, these include Schizothorax niger, Schizothorax esocinus, Schizothorax plagiostomus, Schizothorax curvifrons and Schizothorax labiatus. The relationship between these species is contradicting. To understand the evolutionary relation of these species, we examined the sequence information of mitochondrial D-loop of 25 individuals representing five species. Sequence alignment showed D-loop region highly variable and length variation was observed in di-nucleotide (TA)n microsatellite between and within species. Interestingly, all these species have (TA)n microsatellite not associated with longer tandem repeats at the 3' end of the mitochondrial control region and do not show heteroplasmy. Our analysis also indicates the presence of four conserved sequence blocks (CSB), CSB-D, CSB-1, CSB-II and CSB-III, four (Termination Associated Sequence) TAS motifs and 15bp pyrimidine block within the mitochondrial control region, that are highly conserved within genus Schizothorax when compared with other species. The phylogenetic analysis carried by Maximum likelihood (ML), Neighbor Joining (NJ) and Bayesian inference (BI) generated almost identical results. The resultant BI tree showed a close genetic relationship of all the five species and supports two distinct grouping of S. esocinus species. Besides the species relation, the presence of length variation in tandem repeats is attributed to differences in predicting the stability of secondary structures. The role of CSBs and TASs, reported so far as main regulatory signals, would explain the conservation of these elements in evolution.
Sideband cooling of small ion Coulomb crystals in a Penning trap
NASA Astrophysics Data System (ADS)
Stutter, G.; Hrmo, P.; Jarlaud, V.; Joshi, M. K.; Goodwin, J. F.; Thompson, R. C.
2018-03-01
We have recently demonstrated the laser cooling of a single ? ion to the motional ground state in a Penning trap using the resolved-sideband cooling technique on the electric quadrupole transition S? D?. Here we report on the extension of this technique to small ion Coulomb crystals made of two or three ? ions. Efficient cooling of the axial motion is achieved outside the Lamb-Dicke regime on a two-ion string along the magnetic field axis as well as on two- and three-ion planar crystals. Complex sideband cooling sequences are required in order to cool both axial degrees of freedom simultaneously. We measure a mean excitation after cooling of ? for the centre of mass (COM) mode and ? for the breathing mode of the two-ion string with corresponding heating rates of 11(2) ? and ? at a trap frequency of 162 kHz. The occupation of the ground state of the axial modes (?) is above 75% for the two-ion planar crystal and the associated heating rates 0.8(5) ? at a trap frequency of 355 kHz.
Occurrence of Infected Free-Living Amoebae in Cooling Towers of Southern Brazil.
Soares, Scheila S; Souza, Thamires K; Berté, Francisco K; Cantarelli, Vlademir V; Rott, Marilise B
2017-12-01
This study determined the occurrence of potentially pathogenic free-living amoebae (FLA) and bacteria associated with amoebae in air-conditioning cooling towers in southern Brazil. Water samples were collected from 36 cooling systems from air-conditioning in the state of Rio Grande do Sul, Brazil. The organisms were identified using polymerase chain reaction (PCR) and sequencing automated. The results showed that these aquatic environments, with variable temperature, are potential "hot spots" for emerging human pathogens like free-living amoebae and bacteria associated. In total, 92% of the cooling-tower samples analyzed were positive for FLA, and Acanthamoeba was the dominant genus by culture and PCR. Amoebal isolates revealed intracellular bacteria in 39.3% of them and all were confirmed as members of the genus Pseudomonas. The results obtained show the important role of cooling towers as a source of amoebae-associated pathogens.
Cooling rates of group IVA iron meteorites
NASA Technical Reports Server (NTRS)
Willis, J.; Wasson, J. T.
1978-01-01
Cooling rates of six group IVA iron meteorites were estimated by a taenite central Ni concentration-taenite half-width method. Calculated cooling rates range from 13 to 25 C/Myr, with an average of 20 C/Myr. No correlation between cooling rate and bulk Ni content is observed, and the data appear to be consistent with a uniform cooling rate as expected from an igneous core origin. This result differs from previous studies reporting a wide range in cooling rates that were strongly correlated with bulk Ni content. The differences result mainly from differences in the phase diagram and the selected diffusion coefficients. Cooling rates inferred from taenite Ni concentrations at the interface with kamacite are consistent with those based on taenite central Ni content.
NASA Astrophysics Data System (ADS)
Mottram, Catherine M.; Warren, Clare J.; Halton, Alison M.; Kelley, Simon P.; Harris, Nigel B. W.
2015-12-01
40Ar/39Ar dating of metamorphic rocks sometimes yields complicated datasets which are difficult to interpret in terms of timescales of the metamorphic cycle. Single-grain fusion and step-heating data were obtained for rocks sampled through a major thrust-sense shear zone (the Main Central Thrust) and the associated inverted metamorphic zone in the Sikkim region of the eastern Himalaya. This transect provides a natural laboratory to explore factors influencing apparent 40Ar/39Ar ages in similar lithologies at a variety of metamorphic pressure and temperature (P-T) conditions. The 40Ar/39Ar dataset records progressively younger apparent age populations and a decrease in within-sample dispersion with increasing temperature through the sequence. The white mica populations span 2-9 Ma within each sample in the structurally lower levels (garnet grade) but only 0-3 Ma at structurally higher levels (kyanite-sillimanite grade). Mean white mica single-grain fusion population ages vary from 16.2 ± 3.9 Ma (2σ) to 13.2 ± 1.3 Ma (2σ) from lowest to highest levels. White mica step-heating data from the same samples yields plateau ages from 14.27 ± 0.13 Ma to 12.96 ± 0.05 Ma. Biotite yield older apparent age populations with mean single-grain fusion dates varying from 74.7 ± 11.8 Ma (2σ) at the lowest structural levels to 18.6 ± 4.7 Ma (2σ) at the highest structural levels; the step-heating plateaux are commonly disturbed. Temperatures > 600 °C at pressures of 0.4-0.8 GPa sustained over > 5 Ma, appear to be required for white mica and biotite ages to be consistent with diffusive, open-system cooling. At lower temperatures, and/or over shorter metamorphic timescales, more 40Ar is retained than results from simple diffusion models suggest. Diffusion modelling of Ar in white mica from the highest structural levels suggests that the high-temperature rocks cooled at a rate of 50-80 °C Ma- 1, consistent with rapid thrusting, extrusion and exhumation along the Main Central Thrust during the mid-Miocene.
NASA Astrophysics Data System (ADS)
Bo, Yan; Bu, Wenhao; Chen, Tao; Lv, Guitao
2017-04-01
In this poster, we report our recently experimental progresses in laser cooling of BaF molecule. Our theoretic calculation shows BaF is a good candidate for laser cooling: quasi-cycling transitions, good wavelengths (around 900nm) for the main transitions. We have built a 4K cryogenic machine, laser ablate the target to make BaF molecules. The precise spectroscopy of BaF is measured and the laser cooling related transitions are identified. The collision between BaF and 4K He is carefully characterized. The quasi-cycling transition is demonstrated. And laser cooling experiment is going on.
Linking Dynamical and Stellar Evolution in the Metal-Poor Globular Cluster M92
NASA Astrophysics Data System (ADS)
Kalirai, Jason
2017-08-01
We propose a 5 orbit HST program to acquire UV imaging at the center of the ancient, metal-poor globular cluster NGC 6341 (M92). Our program is designed to achieve two science goals with a single data set, 1.) to directly measure the diffusion of stars through the massive cluster's core, 2.) to pinpoint the phase of post main-sequence evolution at which [Fe/H] = -2.3 stars lose their mass. Our novel technique will achieve these goals by using the full power of WFC3's exquisite UV sensitivity at <0.3 microns combined with its high spatial resolution. We will uncover 1000 newly-formed white dwarfs in the center of M92 and track how their spatial distribution changes as they get older on the cooling sequence. Having just experienced significant mass loss, the youngest remnants with ages <10s of Myr will still be moving slowly like their 0.8 Msun progenitors, whereas the older remnants with t_cool > 100s Myr will be fully relaxed. Using the methodology we developed and successfully applied to 47 Tuc (Heyl et al. 2015a; 2015b), we will watch this dynamical evolution to measure the diffusion coefficient due to gravitational relaxation in the cluster's core and the past timing of stellar mass loss that was responsible for the current cluster mass segregation profile. M92 is the ideal target for this study as it complements our existing study of the relatively metal-rich cluster 47 Tuc; it has an extremely low metallicity of [Fe/H] = -2.3, very low foreground reddening (E(B-V) = 0.02), moderate concentration index, and a theoretically-expected relaxation timescale in its core of 90 Myr, which nicely splits the young and old white dwarfs that can be observed with Hubble.
Low-energy Spectra of Gamma-Ray Bursts from Cooling Electrons
NASA Astrophysics Data System (ADS)
Geng, Jin-Jun; Huang, Yong-Feng; Wu, Xue-Feng; Zhang, Bing; Zong, Hong-Shi
2018-01-01
The low-energy spectra of gamma-ray bursts’ (GRBs) prompt emission are closely related to the energy distribution of electrons, which is further regulated by their cooling processes. We develop a numerical code to calculate the evolution of the electron distribution with given initial parameters, in which three cooling processes (i.e., adiabatic, synchrotron, and inverse Compton cooling) and the effect of a decaying magnetic field are coherently considered. A sequence of results is presented by exploring the plausible parameter space for both the fireball and the Poynting flux–dominated regime. Different cooling patterns for the electrons can be identified, and they are featured by a specific dominant cooling mechanism. Our results show that the hardening of the low-energy spectra can be attributed to the dominance of synchrotron self-Compton cooling within the internal shock model or to decaying synchrotron cooling within the Poynting flux–dominated jet scenario. These two mechanisms can be distinguished by observing the hard low-energy spectra of isolated short pulses in some GRBs. The dominance of adiabatic cooling can also lead to hard low-energy spectra when the ejecta is moving at an extreme relativistic speed. The information from the time-resolved low-energy spectra can help to probe the physical characteristics of the GRB ejecta via our numerical results.
NASA Astrophysics Data System (ADS)
Ma, Libin; Ren, Jianxing
2018-01-01
Large capacity and super large capacity thermal power is becoming the main force of energy and power industry in our country. The performance of cooling tower is related to the water temperature of circulating water, which has an important influence on the efficiency of power plant. The natural draft counter flow wet cooling tower is the most widely used cooling tower type at present, and the high cooling tower is a new cooling tower based on the natural ventilation counter flow wet cooling tower. In this paper, for high cooling tower, the application background of high cooling tower is briefly explained, and then the structure principle of conventional cooling tower and high cooling tower are introduced, and the difference between them is simply compared. Then, the influence of crosswind on cooling performance of high cooling tower under different wind speeds is introduced in detail. Through analysis and research, wind speed, wind cooling had little impact on the performance of high cooling tower; wind velocity, wind will destroy the tower inside and outside air flow, reducing the cooling performance of high cooling tower; Wind speed, high cooling performance of cooling tower has increased, but still lower than the wind speed.
Inoue, Hiroaki; Fujimura, Reiko; Agata, Kunio; Ohta, Hiroyuki
2015-01-01
Viable Legionella spp. in environmental water samples were characterized phylogenetically by a clone library analysis combining the use of ethidium monoazide and quantitative PCR. To examine the diversity of Legionella spp., six cooling tower water samples and three bath water samples were collected and analyzed. A total of 617 clones were analyzed for their 16S rRNA gene sequences and classified into 99 operational taxonomic units (OTUs). The majority of OTUs were not clustered with currently described Legionella spp., suggesting the wide diversity of not-yet-cultured Legionella groups harbored in cooling tower water environments.
Inoue, Hiroaki; Fujimura, Reiko; Agata, Kunio; Ohta, Hiroyuki
2015-01-01
Viable Legionella spp. in environmental water samples were characterized phylogenetically by a clone library analysis combining the use of ethidium monoazide and quantitative PCR. To examine the diversity of Legionella spp., six cooling tower water samples and three bath water samples were collected and analyzed. A total of 617 clones were analyzed for their 16S rRNA gene sequences and classified into 99 operational taxonomic units (OTUs). The majority of OTUs were not clustered with currently described Legionella spp., suggesting the wide diversity of not-yet-cultured Legionella groups harbored in cooling tower water environments. PMID:25736979
Influence of firebed temperature on inorganic particle emissions in a residential wood pellet boiler
NASA Astrophysics Data System (ADS)
Gehrig, Matthias; Jaeger, Dirk; Pelz, Stefan K.; Weissinger, Alexander; Groll, Andreas; Thorwarth, Harald; Haslinger, Walter
2016-07-01
The temperature-dependent release of inorganic elements is the first step of the main formation pathway of particle emissions in automatically fired biomass burners. To investigate this step, a residential pellet boiler with an underfeed-burner was equipped with a direct firebed cooling. This test setup enabled decreased firebed temperatures without affecting further parameters like air flow rates or oxygen content in the firebed. A reduction of particle emissions in PM1-fraction at activated firebed cooling was found by impactor measurement and by optical particle counter. The affected particles were found in the size range <0.3 μm and have been composed mainly of potassium chloride (KCl). The chemical analysis of PM1 and boiler ash showed no statistically significant differences due to the firebed cooling. Therefore, our results indicate that the direct firebed cooling influenced the release of potassium (K) without affecting other chemical reactions.
1990-02-28
include energy costs, time required for cooling, large volume changes, and degradation. For many high -temperature LCPs, the latter may be the most...LCPs)- high local (microscopic) orientational order, which is retained in the solid state-has significant implications in a range of DOD applications...that yield and maintain specific mer sequences. * Continue efforts to measure mer sequence distribution, e.g., by multinuclei NMR. 0 Develop high
Li, Lijie; Qin, Tian; Li, Yun; Zhou, Haijian; Song, Hongmei; Ren, Hongyu; Li, Liping; Li, Yongguang; Zhao, Dong
2015-01-01
Cooling towers are a source of Legionnaires’ disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella. Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 2011 and September 2012. Overall, 35.7% of 255 industrial cooling tower water samples showed Legionella-positive, and their concentrations ranged from 100 Colony-Forming Units (CFU)/liter to 88,000 CFU/liter, with an average concentration of 9100 CFU/liter. A total of 121 isolates were obtained. All isolates were L. pneumophila, and the isolated serogroups included serogroups 1 (68 isolates, 56.2%), 6 (25, 20.7%), 5 (12, 9.9%), 8 (8, 6.6%), 3 (6, 5.0%) and 9 (2, 1.6%). All 121 isolates were analyzed by pulsed-field gel electrophoresis (PFGE) and 64 different patterns were obtained. All 121 isolates were analyzed sequence-based typing (SBT), a full 7-allele profile was obtained from 117 isolates. One hundred and seventeen isolates were divided into 49 sequence types. Two virulence genes, lvh and rtxA, are analyzed by polymerase chain reaction (PCR). 92.6% (112/121) and 98.3% (119/121) isolates carried lvh and rtxA respectively and 90.9% (110/121) of tested isolates carried both genes. Our results demonstrated high prevalence and genetic polymorphism of L. pneumophila in industrial cooling tower environments in Shijiazhang, China, and the SBT and virulence gene PCR results suggested that the isolates were pathogenic. Improved control and prevention strategies are urgently needed. PMID:26473896
Li, Lijie; Qin, Tian; Li, Yun; Zhou, Haijian; Song, Hongmei; Ren, Hongyu; Li, Liping; Li, Yongguang; Zhao, Dong
2015-10-12
Cooling towers are a source of Legionnaires' disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella. Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 2011 and September 2012. Overall, 35.7% of 255 industrial cooling tower water samples showed Legionella-positive, and their concentrations ranged from 100 Colony-Forming Units (CFU)/liter to 88,000 CFU/liter, with an average concentration of 9100 CFU/liter. A total of 121 isolates were obtained. All isolates were L. pneumophila, and the isolated serogroups included serogroups 1 (68 isolates, 56.2%), 6 (25, 20.7%), 5 (12, 9.9%), 8 (8, 6.6%), 3 (6, 5.0%) and 9 (2, 1.6%). All 121 isolates were analyzed by pulsed-field gel electrophoresis (PFGE) and 64 different patterns were obtained. All 121 isolates were analyzed sequence-based typing (SBT), a full 7-allele profile was obtained from 117 isolates. One hundred and seventeen isolates were divided into 49 sequence types. Two virulence genes, lvh and rtxA, are analyzed by polymerase chain reaction (PCR). 92.6% (112/121) and 98.3% (119/121) isolates carried lvh and rtxA respectively and 90.9% (110/121) of tested isolates carried both genes. Our results demonstrated high prevalence and genetic polymorphism of L. pneumophila in industrial cooling tower environments in Shijiazhang, China, and the SBT and virulence gene PCR results suggested that the isolates were pathogenic. Improved control and prevention strategies are urgently needed.
Formation and evolution of coronal rain observed by SDO/AIA on February 22, 2012
NASA Astrophysics Data System (ADS)
Vashalomidze, Z.; Kukhianidze, V.; Zaqarashvili, T. V.; Oliver, R.; Shergelashvili, B.; Ramishvili, G.; Poedts, S.; De Causmaecker, P.
2015-05-01
Context. The formation and dynamics of coronal rain are currently not fully understood. Coronal rain is the fall of cool and dense blobs formed by thermal instability in the solar corona towards the solar surface with acceleration smaller than gravitational free fall. Aims: We aim to study the observational evidence of the formation of coronal rain and to trace the detailed dynamics of individual blobs. Methods: We used time series of the 171 Å and 304 Å spectral lines obtained by the Atmospheric Imaging Assembly (AIA) on board the Solar Dynamic Observatory (SDO) above active region AR 11420 on February 22, 2012. Results: Observations show that a coronal loop disappeared in the 171 Å channel and appeared in the 304 Å line more than one hour later, which indicates a rapid cooling of the coronal loop from 1 MK to 0.05 MK. An energy estimation shows that the radiation is higher than the heat input, which indicates so-called catastrophic cooling. The cooling was accompanied by the formation of coronal rain in the form of falling cold plasma. We studied two different sequences of falling blobs. The first sequence includes three different blobs. The mean velocities of the blobs were estimated to be 50 km s-1, 60 km s-1 and 40 km s-1. A polynomial fit shows the different values of the acceleration for different blobs, which are lower than free-fall in the solar corona. The first and second blob move along the same path, but with and without acceleration, respectively. We performed simple numerical simulations for two consecutive blobs, which show that the second blob moves in a medium that is modified by the passage of the first blob. Therefore, the second blob has a relatively high speed and no acceleration, as is shown by observations. The second sequence includes two different blobs with mean velocities of 100 km s-1 and 90 km s-1, respectively. Conclusions: The formation of coronal rain blobs is connected with the process of catastrophic cooling. The different acceleration of different coronal rain blobs might be due to the different values in the density ratio of blob to corona. All blobs leave trails, which might be a result of continuous cooling in their tails. Two movies attached to Fig. 1 are available in electronic form at http://www.aanda.org
Role of moisture and density of sand for microwave enhancement of thermal detection of buried mines
NASA Astrophysics Data System (ADS)
Swiderski, Waldemar; Hlosta, Pawel; Jarzemski, Jozef; Szugajew, Leszek; Usowicz, Jerzy
2012-06-01
The main disadvantage of applying the IRT method is presence of plenty false indications in thermograms. A simple use of IRT equipment with better temperature resolution would not help in distinguishing the mines, since noise comes not from a camera, but from soil surface. Recognizing the role of moisture and density of sand and possibilities to express it quantitatively plays an important role. In our model of thermal properties of the soil the volumetric unit of the soil consists of mineral and organic particles, as well as water and air. All needed parameters can be calculated. Calculations of thermal signatures of the underground objects were made basing on 3D-heat equation for the sinus type heating of 3D model and cooling by convection. Measurements were made for field and laboratory stand-ups, using methodologies typical for "single-shot" measurements as well as analyses of transient processes based on sequence of thermograms. Results of simulations and measurements confirm expectation tha that high level of "radiant noises" is caused mainly by differences in the moisture and sand density levels.
Physical installation of Pelletron and electron cooling system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurh, P.
1997-09-01
Bremsstrahlung of 5 MeV electrons at a loss current of 50 microamp in the acceleration region is estimated to produce X-ray intensities of 7 Rad/sec. Radiation losses due to a misteer or sudden obstruction will of course be much higher still (estimated at 87,500 Rad/hr for a 0.5 mA beam current). It is estimated that 1.8 meters of concrete will be necessary to adequately shield the surrounding building areas at any possible Pelletron installation site. To satisfy our present electron cooling development plan, two Pelletron installations are required, the first at our development lab in the Lab B/NEF Enclosure areamore » and the second at the operational Main Injector service building, MI-30, in the main Injector ring. The same actual Pelletron and electron beam-line components will be used at both locations. The Lab B installation will allow experimentation with actual high energy electron beam to develop the optics necessary for the cooling straight while Main Injector/Recycler commissioning is taking place. The MI-30 installation is obviously the permanent home for the Pelletron when electron cooling becomes operational. Construction plans for both installations will be discussed here.« less
Effects of disc mid-plane evolution on CO snowline location
NASA Astrophysics Data System (ADS)
Panić, O.; Min, M.
2017-05-01
Temperature changes in the planet forming disc mid-planes carry important physico-chemical consequences, such as the effect on the locations of the condensation fronts of molecules - the snowlines. Snowlines impose major chemical gradients and possibly foster grain growth. The aim of this paper is to understand how disc mid-plane temperature changes with gas and dust evolution, and identify trends that may influence planet formation or allow to constrain disc evolution observationally. We calculate disc temperature, hydrostatic equilibrium and dust settling in a mutually consistent way from a grid of disc models at different stages of gas loss, grain growth and hole opening. We find that the CO snowline location depends very strongly on disc properties. The CO snowline location migrates closer to the star for increasing degrees of gas dispersal and dust growth. Around a typical A-type star, the snowline can be anywhere between several tens and a few hundred au, depending on the disc properties such as gas mass and grain size. In fact, gas loss is as efficient as dust evolution in settling discs, and flat discs may be gas-poor counterparts of flared discs. Our results, in the context of different pre-main-sequence evolution of the luminosity in low- and intermediate-mass stars suggest very different thermal (and hence chemical) histories in these two types of discs. Discs of T Tauri stars settle and cool down, while discs of Herbig Ae stars may remain rather warm throughout the pre-main sequence.
Ginkgo biloba's footprint of dynamic Pleistocene history dates back only 390,000 years ago.
Hohmann, Nora; Wolf, Eva M; Rigault, Philippe; Zhou, Wenbin; Kiefer, Markus; Zhao, Yunpeng; Fu, Cheng-Xin; Koch, Marcus A
2018-04-27
At the end of the Pliocene and the beginning of Pleistocene glaciation and deglaciation cycles Ginkgo biloba went extinct all over the world, and only few populations remained in China in relict areas serving as sanctuary for Tertiary relict trees. Yet the status of these regions as refuge areas with naturally existing populations has been proven not earlier than one decade ago. Herein we elaborated the hypothesis that during the Pleistocene cooling periods G. biloba expanded its distribution range in China repeatedly. Whole plastid genomes were sequenced, assembled and annotated, and sequence data was analyzed in a phylogenetic framework of the entire gymnosperms to establish a robust spatio-temporal framework for gymnosperms and in particular for G. biloba Pleistocene evolutionary history. Using a phylogenetic approach, we identified that Ginkgoatae stem group age is about 325 million years, whereas crown group radiation of extant Ginkgo started not earlier than 390,000 years ago. During repeated warming phases, Gingko populations were separated and isolated by contraction of distribution range and retreated into mountainous regions serving as refuge for warm-temperate deciduous forests. Diversification and phylogenetic splits correlate with the onset of cooling phases when Ginkgo expanded its distribution range and gene pools merged. Analysis of whole plastid genome sequence data representing the entire spatio-temporal genetic variation of wild extant Ginkgo populations revealed the deepest temporal footprint dating back to approximately 390,000 years ago. Present-day directional West-East admixture of genetic diversity is shown to be the result of pronounced effects of the last cooling period. Our evolutionary framework will serve as a conceptual roadmap for forthcoming genomic sequence data, which can then provide deep insights into the demographic history of Ginkgo.
The influence of liquid-gas velocity ratio on the noise of the cooling tower
NASA Astrophysics Data System (ADS)
Yang, Bin; Liu, Xuanzuo; Chen, Chi; Zhao, Zhouli; Song, Jinchun
2018-05-01
The noise from the cooling tower has a great influence on psychological performance of human beings. The cooling tower noise mainly consists of fan noise, falling water noise and mechanical noise. This thesis used DES turbulence model with FH-W model to simulate the flow and sound pressure field in cooling tower based on CFD software FLUENT and analyzed the influence of different kinds noise, which affected by diverse factors, on the cooling tower noise. It can be concluded that the addition of cooling water can reduce the turbulence and vortex noise of the rotor fluid field in the cooling tower at some extent, but increase the impact noise of the liquid-gas two phase. In general, the cooling tower noise decreases with the velocity ratio of liquid to gas increasing, and reaches the lowest when the velocity ratio of liquid to gas is close to l.
On the Time Scale of Nocturnal Boundary Layer Cooling in Valleys and Basins and over Plains
NASA Astrophysics Data System (ADS)
de Wekker, Stephan F. J.; Whiteman, C. David
2006-06-01
Sequences of vertical temperature soundings over flat plains and in a variety of valleys and basins of different sizes and shapes were used to determine cooling-time-scale characteristics in the nocturnal stable boundary layer under clear, undisturbed weather conditions. An exponential function predicts the cumulative boundary layer cooling well. The fitting parameter or time constant in the exponential function characterizes the cooling of the valley atmosphere and is equal to the time required for the cumulative cooling to attain 63.2% of its total nighttime value. The exponential fit finds time constants varying between 3 and 8 h. Calculated time constants are smallest in basins, are largest over plains, and are intermediate in valleys. Time constants were also calculated from air temperature measurements made at various heights on the sidewalls of a small basin. The variation with height of the time constant exhibited a characteristic parabolic shape in which the smallest time constants occurred near the basin floor and on the upper sidewalls of the basin where cooling was governed by cold-air drainage and radiative heat loss, respectively.
NASA Astrophysics Data System (ADS)
Willcock, M. A. W.; Cas, R. A. F.
2014-06-01
Exceptional exposure through a Permian intra-caldera ignimbrite fill within the 42 × 40 km Ora caldera (>1,290 km3 erupted volume) provides an opportunity to study welding textures in a thick intra-caldera ignimbrite succession. The ignimbrite succession records primary dense welding, a simple cooling unit structure, common crystallisation zones, and remarkably preserves fresh to slightly hydrated glass in local vitrophyre zones. Evidence for primary syn- and post-emplacement welding consists of (a) viscously deformed and sintered juvenile glass and relict shard textures; (b) complete deposit welding; (c) subtle internal welding intensity variations; (d) vitrophyre preserved locally at the base of the ignimbrite succession; (e) persistent fiamme juvenile clast shapes throughout the succession at the macroscopic and microscopic scales, defining a moderate to well-developed eutaxitic texture; (f) common undulating juvenile clast (pumice) margins and feathery terminations; (g) a general loss of deposit porosity; and (h) perlitic fracturing. A low collapsing or fountaining explosive eruption column model is proposed to have facilitated the ubiquitous welding of the deposit, which in turn helped preserve original textures. The ignimbrite succession preserves no evidence of a time break through the sequence and columnar joints cross-gradational ignimbrite lithofacies boundaries, so the ignimbrite is interpreted to represent a simple cooling unit. Aspect ratio and anisotropy of magnetic susceptibility (AMS) analyses through stratigraphic sections within the thick intra-caldera succession and at the caldera margin reveal variable welding compaction and strain profiles. Significantly, these data show that welding degree/intensity may vary in an apparently simple cooling unit because of variations in eruption process recorded in differing lithofacies. These data imply complex eruption, emplacement, and cooling processes. Three main crystallisation textural zones are identified in the ignimbrite succession: localised vitrophyre zones, widespread microcrystalline to sparsely spherulitic pseudomorphed vitriclastic textural zones, and thick granophyric zones. These zones record a typical spectrum from rapid to prolonged cooling. The non-uniform crystallisation patterns reflect variations in deposit thickness, the relative position of deposits within the larger ignimbrite succession, the type of substrate material, and the degree of confinement in the intra-caldera setting. We support previous work suggesting that traditional welding classifications (e.g. Smith, US Geological Survey Professional Paper 354-F 1960b) are most appropriate for use within altered and/or ancient ignimbrite successions.
NASA Astrophysics Data System (ADS)
Repko, Timothy William
A novel film cooling hole geometry for use in gas turbine engines has been investigated numerically by solving the Reynolds Averaged Navier-Stokes equations in a commercial CFD code (STAR-CCM+) with varying turbulence intensity and length scale using the k-o SST turbulence model. Both steady and unsteady results were considered in order to investigate the effects of freestream turbulence intensity and length scale on this novel anti-vortex hole (AVH) concept. The AVH geometry utilizes two side holes, one on each side of the main hole, to attempt to mitigate the vorticity from the jet from the main hole. The AVH concept has been shown by past research to provide a substantial improvement over conventional film cooling hole designs. Past research has been limited to low turbulence intensity and small length scales that are not representative of the turbulent flow exiting the combustor. Three turbulence intensities (Tu = 5, 10 and 20%) and three length scales normalized by the main cooling hole diameter (Λ x/dm = 1, 3, 6) were considered in this study for a total of nine turbulence conditions. The highest intensity, largest length scale turbulence case (Tu = 20, Λx/dm = 6) is considered most representative of engine conditions and was shown to have the best cooling performance. Results show that the turbulence in the hot gases exiting the combustor can aid in the film cooling for the AVH geometry at high blowing ratios (BR = 2.0), where the blowing ratio is essentially the ratio of the jet-to-mainstream mass flux ratios. Length scale was shown to have an insignificant effect on the cooling performance at low turbulence intensity and a moderate effect at higher turbulence intensities. The adiabatic film cooling effectiveness was shown to increase as the turbulence intensity was elevated. The convective heat transfer coefficient was also shown to increase at the turbulence intensity was elevated. An increase in the heat transfer coefficient is a deleterious effect and must be weighed against the improvements in the adiabatic cooling effectiveness. The net heat flux reduction (NHFR) is the parameter used to quantify the net benefit of film cooling. As a general trend, the NHFR was shown to increase with the turbulence intensity in all cases.
SNS Resonance Control Cooling Systems and Quadrupole Magnet Cooling Systems DIW Chemistry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Magda, Karoly
This report focuses on control of the water chemistry for the Spallation Neutron Source (SNS) Resonance Control Cooling System (RCCS)/Quadrupole Magnet Cooling System (QMCS) deionized water (DIW) cooling loops. Data collected from spring 2013 through spring 2016 are discussed, and an operations regime is recommended.It was found that the RCCS operates with an average pH of 7.24 for all lines (from 7.0 to 7.5, slightly alkaline), the average low dissolved oxygen is in the area of < 36 ppb, and the main loop average resistivity of is > 14 MΩ-cm. The QMCS was found to be operating in a similarmore » regime, with a slightly alkaline pH of 7.5 , low dissolved oxygen in the area of < 45 ppb, and main loop resistivity of 10 to 15 MΩ-cm. During data reading, operational corrections were done on the polishing loops to improve the water chemistry regime. Therefore some trends changed over time.It is recommended that the cooling loops operate in a regime in which the water has a resistivity that is as high as achievable, a dissolved oxygen concentration that is as low as achievable, and a neutral or slightly alkaline pH.« less
Space station freedom resource nodes internal thermal control system
NASA Technical Reports Server (NTRS)
Merhoff, Paul; Dellinger, Brent; Taggert, Shawn; Cornwell, John
1993-01-01
This paper presents an overview of the design and operation of the internal thermal control system (ITCS) developed for Space Station Freedom by the NASA-Johnson Space Center and McDonnell Douglas Aerospace to provide cooling for the resource nodes, airlock, and pressurized logistics modules. The ITCS collects, transports and rejects waste heat from these modules by a dual-loop, single-phase water cooling system. ITCS performance, cooling, and flow rate requirements are presented. An ITCS fluid schematic is shown and an overview of the current baseline system design and its operation is presented. Assembly sequence of the ITCS is explained as its configuration develops from Man Tended Capability (MTC), for which node 2 alone is cooled, to Permanently Manned Capability (PMC) where the airlock, a pressurized logistics module, and node 1 are cooled, in addition to node 2. A SINDA/FLUINT math model of the ITCS is described, and results of analyses for an MTC and a PMC case are shown and discussed.
Subresolution Fibrillation in X-Ray Microflares Observed by Yohkoh SXT
NASA Technical Reports Server (NTRS)
Moore, Ron; Falconer, David; Porter, Jason
1999-01-01
We analyze the cooling of the X-ray plasma in microflares observed in active regions by the Yohkoh Soft X-ray Telescope (SXT). A typical microflare appears to be a transient brightening of an entire small magnetic loop, often having a diameter near the limit of resolution (approx. 2 x 10(exp 8) cm). The plasma heated to X-ray temperatures in the body of the loop cools by emission of XUV radiation and by heat conduction to the cooler plasma at the feet of the loop. The cooling rate is determined by the plasma temperature and density and the loop length. The plasma density is determined from the observed X-ray brightness of the loop in combination with the temperature, the loop diameter, and the filling factor. The filling factor is the volume fraction of the loop occupied by the subset of magnetic tubes that is fluid by the X-ray plasma and that contains practically all of the X-ray plasma present in the microflare loop. Taking typical values from the hundreds of microflares measured by Shimizu (X-ray brightness through the thin aluminum filter - 4 x 10(exp 3) DN/s/pixeL lifetime approx. 5 min, temperature approx. 6 x 10(exp 6) K, loop length approx. 10(exp 9) cm, loop diameter approx. 3 x 10(exp 8) cm), we find that for filling factors greater than approx. 1%: (1) the cooling time is much shorter than the duration of the microflare, and (2) conductive cooling strongly dominates over radiative cooling. Because the cooling time is so short and because the conductive heat flux goes mainly into increasing the plasma density via chromospheric evaporation, we are compelled to conclude that: (1) heating to X-ray temperatures continues through nearly the entire lifetime of the microflare, (2) die heating keeps changing to different field lines, so that any one magnetic tube in the sequence of heated tubes emits X-rays only briefly in the life of the microflare, and (3) at any instant during the microflare the tubes filled with X-ray plasma occupy only a small fraction (approx. 10%) of the microflare loop. Hence, we expect that coronal X-ray images with spatial resolution 2-3 times better than from the Yohkoh SXT will show plenty of rapidly changing filamentary substructure in microflares. Our results also suggest that the heating in microflares may result from progressive reconnection similar to that inferred in many larger flares.
NASA Astrophysics Data System (ADS)
Yang, Yang; Ren, R.-C.; Cai, Ming
2016-12-01
The stratosphere has been cooling under global warming, the causes of which are not yet well understood. This study applied a process-based decomposition method (CFRAM; Coupled Surface-Atmosphere Climate Feedback Response Analysis Method) to the simulation results of a Coupled Model Intercomparison Project, phase 5 (CMIP5) model (CCSM4; Community Climate System Model, version 4), to demonstrate the responsible radiative and non-radiative processes involved in the stratospheric cooling. By focusing on the long-term stratospheric temperature changes between the "historical run" and the 8.5 W m-2 Representative Concentration Pathway (RCP8.5) scenario, this study demonstrates that the changes of radiative radiation due to CO2, ozone and water vapor are the main divers of stratospheric cooling in both winter and summer. They contribute to the cooling changes by reducing the net radiative energy (mainly downward radiation) received by the stratospheric layer. In terms of the global average, their contributions are around -5, -1.5, and -1 K, respectively. However, the observed stratospheric cooling is much weaker than the cooling by radiative processes. It is because changes in atmospheric dynamic processes act to strongly mitigate the radiative cooling by yielding a roughly 4 K warming on the global average base. In particular, the much stronger/weaker dynamic warming in the northern/southern winter extratropics is associated with an increase of the planetary-wave activity in the northern winter, but a slight decrease in the southern winter hemisphere, under global warming. More importantly, although radiative processes dominate the stratospheric cooling, the spatial patterns are largely determined by the non-radiative effects of dynamic processes.
Mesa Isochrones and Stellar Tracks (MIST). I. Solar-scaled Models
NASA Astrophysics Data System (ADS)
Choi, Jieun; Dotter, Aaron; Conroy, Charlie; Cantiello, Matteo; Paxton, Bill; Johnson, Benjamin D.
2016-06-01
This is the first of a series of papers presenting the Modules for Experiments in Stellar Astrophysics (MESA) Isochrones and Stellar Tracks (MIST) project, a new comprehensive set of stellar evolutionary tracks and isochrones computed using MESA, a state-of-the-art open-source 1D stellar evolution package. In this work, we present models with solar-scaled abundance ratios covering a wide range of ages (5≤slant {log}({Age}) [{year}]≤slant 10.3), masses (0.1≤slant M/{M}⊙ ≤slant 300), and metallicities (-2.0≤slant [{{Z}}/{{H}}]≤slant 0.5). The models are self-consistently and continuously evolved from the pre-main sequence (PMS) to the end of hydrogen burning, the white dwarf cooling sequence, or the end of carbon burning, depending on the initial mass. We also provide a grid of models evolved from the PMS to the end of core helium burning for -4.0≤slant [{{Z}}/{{H}}]\\lt -2.0. We showcase extensive comparisons with observational constraints as well as with some of the most widely used existing models in the literature. The evolutionary tracks and isochrones can be downloaded from the project website at http://waps.cfa.harvard.edu/MIST/.
NASA Technical Reports Server (NTRS)
Sucec, J.
1975-01-01
Solutions for the surface temperature and surface heat flux are found for laminar, constant property, slug flow over a plate convectively cooled from below, when the temperature of the fluid over the plate varies arbitrarily with time at the plate leading edge. A simple technique is presented for handling arbitrary fluid temperature variation with time by approximating it by a sequence of ramps or steps for which exact analytical solutions are available.
NASA Astrophysics Data System (ADS)
Alekseev, V. A.; Krylova, D. D.
1996-02-01
The analytical investigation of Bloch equations is used to describe the main features of the 1D velocity selective coherent population trapping cooling scheme. For the initial stage of cooling the fraction of cooled atoms is derived in the case of a Gaussian initial velocity distribution. At very long times of interaction the fraction of cooled atoms and the velocity distribution function are described by simple analytical formulae and do not depend on the initial distribution. These results are in good agreement with those of Bardou, Bouchaud, Emile, Aspect and Cohen-Tannoudji based on statistical analysis in terms of Levy flights and with Monte-Carlo simulations of the process.
NASA Technical Reports Server (NTRS)
Chato, J. C.; Shitzer, A.
1971-01-01
An analytical method was developed to estimate the amount of heat extracted from an artery running close to the skin surface which is cooled in a symmetrical fashion by a cooling strip. The results indicate that the optimum width of a cooling strip is approximately three times the depth to the centerline of the artery. The heat extracted from an artery with such a strip is about 0.9 w/m-C which is too small to affect significantly the temperature of the blood flow through a main blood vessel, such as the carotid artery. The method is applicable to veins as well.
NASA Astrophysics Data System (ADS)
Wang, H. C.; Chen, G. F.; Gong, M. Q.; Li, X.
2017-12-01
Thermodynamic performance comparison of single-stage mixed-refrigerant Joule-Thomson cycle (MJTR) and pure refrigerant reverse Brayton cycle (RBC) for cooling 80 to 120 K temperature-distributed heat loads was conducted in this paper. Nitrogen under various liquefaction pressures was employed as the heat load. The research was conducted under nonideal conditions by exergy analysis methods. Exergy efficiency and volumetric cooling capacity are two main evaluation parameters. Exergy loss distribution in each process of refrigeration cycle was also investigated. The exergy efficiency and volumetric cooling capacity of MJTR were obviously superior to RBC in 90 to 120 K temperature zone, but still inferior to RBC at 80 K. The performance degradation of MJTR was caused by two main reasons: The high fraction of neon resulted in large entropy generation and exergy loss in throttling process. Larger duty and WLMTD lead to larger exergy losses in recuperator.
Uncertainty in the delayed neutron fraction in fuel assembly depletion calculations
NASA Astrophysics Data System (ADS)
Aures, Alexander; Bostelmann, Friederike; Kodeli, Ivan A.; Velkov, Kiril; Zwermann, Winfried
2017-09-01
This study presents uncertainty and sensitivity analyses of the delayed neutron fraction of light water reactor and sodium-cooled fast reactor fuel assemblies. For these analyses, the sampling-based XSUSA methodology is used to propagate cross section uncertainties in neutron transport and depletion calculations. Cross section data is varied according to the SCALE 6.1 covariance library. Since this library includes nu-bar uncertainties only for the total values, it has been supplemented by delayed nu-bar uncertainties from the covariance data of the JENDL-4.0 nuclear data library. The neutron transport and depletion calculations are performed with the TRITON/NEWT sequence of the SCALE 6.1 package. The evolution of the delayed neutron fraction uncertainty over burn-up is analysed without and with the consideration of delayed nu-bar uncertainties. Moreover, the main contributors to the result uncertainty are determined. In all cases, the delayed nu-bar uncertainties increase the delayed neutron fraction uncertainty. Depending on the fuel composition, the delayed nu-bar values of uranium and plutonium in fact give the main contributions to the delayed neutron fraction uncertainty for the LWR fuel assemblies. For the SFR case, the uncertainty of the scattering cross section of U-238 is the main contributor.
Berk, S G; Gunderson, J H; Newsome, A L; Farone, A L; Hayes, B J; Redding, K S; Uddin, N; Williams, E L; Johnson, R A; Farsian, M; Reid, A; Skimmyhorn, J; Farone, M B
2006-12-01
Many species of bacteria pathogenic to humans, such as Legionella, are thought to have evolved in association with amoebal hosts. Several novel unculturable bacteria related to Legionella have also been found in amoebae, a few of which have been thought to be causes of nosocomial infections in humans. Because amoebae can be found in cooling towers, we wanted to know whether cooling tower environments might enhance the association between amoebae and bacterial pathogens of amoebae in order to identify potential "hot spots" for emerging human pathogens. To compare occurrence of infected amoebae in natural environments with those in cooling towers, 40 natural aquatic environments and 40 cooling tower samples were examined. Logistic regression analysis determined variables that were significant predictors of the occurrence of infected amoebae, which were found in 22 of 40 cooling tower samples but in only 3 of the 40 natural samples. An odds ratio showed that it is over 16 times more likely to encounter infected amoebae in cooling towers than in natural environments. Environmental data from cooling towers and natural habitats combined revealed dissolved organic carbon (DOC) and pH were predictors of the occurrence of the pathogens, however, when cooling tower data alone were analyzed, no variables accounted for the occurrence. Several bacteria have novel rRNA sequences, and most strains were not culturable outside of amoebae. Such pathogens of amoebae may spread to the environment via aerosols from cooling towers. Studies of emerging infectious diseases should strongly consider cooling towers as a source of amoeba-associated pathogens.
NASA Astrophysics Data System (ADS)
Kubin, M.; Ofner, B.; Holzgruber, H.; Schneider, R.; Enzenhofer, D.; Filzwieser, A.; Konetschnik, S.
2016-07-01
One of the main benefits of the ESR process is to obtain an ingot surface which is smooth and allows a subsequent forging operation without any surface dressing. The main influencing factor on surface quality is the precise controlling of the process such as melt rate and electrode immersion depth. However, the relatively strong cooling effect of water as a cooling medium can result in the solidification of the meniscus of the liquid steel on the boundary liquid steel and slag which is most likely the origin of surface defects. The usage of different cooling media like ionic liquids, a salt solution which can be heated up to 250°C operating temperature might diminish the meniscus solidification phenomenon. This paper shows the first results of the usage of an ionic liquid as a mould cooling medium. In doing so, 210mm diameter ESR ingots were produced with the laboratory scale ESR furnace at the university of applied science using an ionic liquid cooling device developed by the company METTOP. For each trial melt different inlet and outlet temperatures of the ionic liquid were chosen and the impact on the surface appearance and internal quality were analyzed. Furthermore the influence on the energy balance is also briefly highlighted. Ultimately, an effect of the usage of ionic liquids as a cooling medium could be determined and these results will be described in detail within the scope of this paper.
Automated sample exchange and tracking system for neutron research at cryogenic temperatures
NASA Astrophysics Data System (ADS)
Rix, J. E.; Weber, J. K. R.; Santodonato, L. J.; Hill, B.; Walker, L. M.; McPherson, R.; Wenzel, J.; Hammons, S. E.; Hodges, J.; Rennich, M.; Volin, K. J.
2007-01-01
An automated system for sample exchange and tracking in a cryogenic environment and under remote computer control was developed. Up to 24 sample "cans" per cycle can be inserted and retrieved in a programed sequence. A video camera acquires a unique identification marked on the sample can to provide a record of the sequence. All operations are coordinated via a LABVIEW™ program that can be operated locally or over a network. The samples are contained in vanadium cans of 6-10mm in diameter and equipped with a hermetically sealed lid that interfaces with the sample handler. The system uses a closed-cycle refrigerator (CCR) for cooling. The sample was delivered to a precooling location that was at a temperature of ˜25K, after several minutes, it was moved onto a "landing pad" at ˜10K that locates the sample in the probe beam. After the sample was released onto the landing pad, the sample handler was retracted. Reading the sample identification and the exchange operation takes approximately 2min. The time to cool the sample from ambient temperature to ˜10K was approximately 7min including precooling time. The cooling time increases to approximately 12min if precooling is not used. Small differences in cooling rate were observed between sample materials and for different sample can sizes. Filling the sample well and the sample can with low pressure helium is essential to provide heat transfer and to achieve useful cooling rates. A resistive heating coil can be used to offset the refrigeration so that temperatures up to ˜350K can be accessed and controlled using a proportional-integral-derivative control loop. The time for the landing pad to cool to ˜10K after it has been heated to ˜240K was approximately 20min.
Fuel injector for use in a gas turbine engine
Wiebe, David J.
2012-10-09
A fuel injector in a combustor apparatus of a gas turbine engine. An outer wall of the injector defines an interior volume in which an intermediate wall is disposed. A first gap is formed between the outer wall and the intermediate wall. The intermediate wall defines an internal volume in which an inner wall is disposed. A second gap is formed between the intermediate wall and the inner wall. The second gap receives cooling fluid that cools the injector. The cooling fluid provides convective cooling to the intermediate wall as it flows within the second gap. The cooling fluid also flows through apertures in the intermediate wall into the first gap where it provides impingement cooling to the outer wall and provides convective cooling to the outer wall. The inner wall defines a passageway that delivers fuel into a liner downstream from a main combustion zone.
NASA Technical Reports Server (NTRS)
Koizumi, E.; Mikouchi, T.; McKay, G.; Schwandt, C.; Monkawa, A.; Miyamoto, M.
2002-01-01
Although many basaltic shergottites have been recently found in north African deserts, QUE94201 basaltic shergottite (QUE) is still important because of its particular mineralogical and petrological features. This meteorite is thought to represent its parent melt composition [1 -3] and to crystallize under most reduced condition in this group [1,4]. We performed experimental study by using the synthetic glass that has the same composition as the bulk of QUE. After homogenization for 48 hours at 1300 C, isothermal and cooling experiments were done under various conditions (e.g. temperature, cooling rates, and redox states). Our goals are (1) to verify that QUE really represents its parent melt composition, (2) to estimate a cooling rate of this meteorite, (3) to clarify the crystallization sequences of present minerals, and (4) to verity that this meteorite really crystallized under reduced condition.
Sequential cooling insert for turbine stator vane
Jones, Russell B.; Krueger, Judson J.; Plank, William L.
2014-04-01
A sequential impingement cooling insert for a turbine stator vane that forms a double impingement for the pressure and suction sides of the vane or a triple impingement. The insert is formed from a sheet metal formed in a zigzag shape that forms a series of alternating impingement cooling channels with return air channels, where pressure side and suction side impingement cooling plates are secured over the zigzag shaped main piece. Another embodiment includes the insert formed from one or two blocks of material in which the impingement channels and return air channels are machined into each block.
Sequential cooling insert for turbine stator vane
Jones, Russel B; Krueger, Judson J; Plank, William L
2014-11-04
A sequential impingement cooling insert for a turbine stator vane that forms a double impingement for the pressure and suction sides of the vane or a triple impingement. The insert is formed from a sheet metal formed in a zigzag shape that forms a series of alternating impingement cooling channels with return air channels, where pressure side and suction side impingement cooling plates are secured over the zigzag shaped main piece. Another embodiment includes the insert formed from one or two blocks of material in which the impingement channels and return air channels are machined into each block.
Influence of Chlorine Emissions on Ozone Levels in the Troposphere
Chlorine emissions from cooling towers are emitted mainly as hypochlous acid, not as molecular chlorine. Chlorine emissions from cooling towers in electric utilities in the U.S. are estimated to be 4,400 tons per year. Molecular chlorine increases more tropospheric ozone than hyp...
Skarecky, Douglas; Yu, Hon; Linehan, Jennifer; Morales, Blanca; Su, Min-Ying; Fwu, Peter; Ahlering, Thomas
2017-10-01
To study the combination of thermal magnetic resonance imaging (MRI) and novel hypothermic cooling, via an endorectal cooling balloon (ECB), to assess the effective dispersion and temperature drop in pelvic tissue to potentially reduce inflammatory cascade in surgical applications. Three male subjects, before undergoing robot-assisted radical prostatectomy, were cooled via an ECB, rendered MRI compatible for patient safety before ECB hypothermia. MRI studies were performed using a 3T scanner and included T2-weighted anatomic scan for the pelvic structures, followed by a temperature mapping scan. The sequence was performed repeatedly during the cooling experiment, whereas the phase data were collected using an integrated MR-high-intensity focused ultrasound workstation in real time. Pelvic cooling was instituted with a cooling console located outside the MRI magnet room. The feasibility of pelvic cooling measured a temperature drop of the ECB of 20-25 degrees in real time was achieved after an initial time delay of 10-15 seconds for the ECB to cool. The thermal MRI anatomic images of the prostate and neurovascular bundle demonstrate cooling at this interface to be 10-15 degrees, and also that cooling extends into the prostate itself ~5 degrees, and disperses into the pelvic region as well. An MRI-compatible ECB coupled with thermal MRI is a feasible method to assess effective hypothermic diffusion and saturation to pelvic structures. By inference, hypothermia-induced rectal cooling could potentially reduce inflammation, scarring, and fistula in radical prostatectomy, as well as other urologic tissue procedures of high-intensity focused ultrasound, external beam radiation therapy, radioactive seed implants, transurethral microwave therapy, and transurethral resection of the prostate. Copyright © 2017 Elsevier Inc. All rights reserved.
Design of energy efficient building with radiant slab cooling
NASA Astrophysics Data System (ADS)
Tian, Zhen
2007-12-01
Air-conditioning comprises a substantial fraction of commercial building energy use because of compressor-driven refrigeration and fan-driven air circulation. Core regions of large buildings require year-round cooling due to heat gains from people, lights and equipment. Negative environmental impacts include CO2 emissions from electric generation and leakage of ozone-depleting refrigerants. Some argue that radiant cooling simultaneously improves building efficiency and occupant thermal comfort, and that current thermal comfort models fail to reflect occupant experience with radiant thermal control systems. There is little field evidence to test these claims. The University of Calgary's Information and Communications Technology (ICT) Building, is a pioneering radiant slab cooling installation in North America. Thermal comfort and energy performance were evaluated. Measurements included: (1) heating and cooling energy use, (2) electrical energy use for lighting and equipment, and (3) indoor temperatures. Accuracy of a whole building energy simulation model was evaluated with these data. Simulation was then used to compare the radiant slab design with a conventional (variable air volume) system. The radiant system energy performance was found to be poorer mainly due to: (1) simultaneous cooling by the slab and heating by other systems, (2) omission of low-exergy (e.g., groundwater) cooling possible with the high cooling water temperatures possible with radiant slabs and (3) excessive solar gain and conductive heat loss due to the wall and fenestration design. Occupant thermal comfort was evaluated through questionnaires and concurrent measurement of workstation comfort parameters. Analysis of 116 sets of data from 82 occupants showed that occupant assessment was consistent with estimates based on current thermal comfort models. The main thermal comfort improvements were reductions in (1) local discomfort from draft and (2) vertical air temperature stratification. The analysis showed that integrated architectural and mechanical design is required to achieve the potential benefits of radiant slab cooling, including: (1) reduction of peak solar gain via windows through (a) avoiding large window-to-wall ratios and/or (b) exterior shading of windows, (2) use of low-quality cooling sources such as cooling towers and ground water, especially in cold, dry climates, and (3) coordination of system control to avoid simultaneous heating and cooling.
NASA Technical Reports Server (NTRS)
Lansing, F. L.; Chai, V. W.; Lascu, D.; Urbenajo, R.; Wong, P.
1978-01-01
The engineering manual provides a complete companion documentation about the structure of the main program and subroutines, the preparation of input data, the interpretation of output results, access and use of the program, and the detailed description of all the analytic, logical expressions and flow charts used in computations and program structure. A numerical example is provided and solved completely to show the sequence of computations followed. The program is carefully structured to reduce both user's time and costs without sacrificing accuracy. The user would expect a cost of CPU time of approximately $5.00 per building zone excluding printing costs. The accuracy, on the other hand, measured by deviation of simulated consumption from watt-hour meter readings, was found by many simulation tests not to exceed + or - 10 percent margin.
A new time tree reveals Earth history's imprint on the evolution of modern birds.
Claramunt, Santiago; Cracraft, Joel
2015-12-01
Determining the timing of diversification of modern birds has been difficult. We combined DNA sequences of clock-like genes for most avian families with 130 fossil birds to generate a new time tree for Neornithes and investigated their biogeographic and diversification dynamics. We found that the most recent common ancestor of modern birds inhabited South America around 95 million years ago, but it was not until the Cretaceous-Paleogene transition (66 million years ago) that Neornithes began to diversify rapidly around the world. Birds used two main dispersion routes: reaching the Old World through North America, and reaching Australia and Zealandia through Antarctica. Net diversification rates increased during periods of global cooling, suggesting that fragmentation of tropical biomes stimulated speciation. Thus, we found pervasive evidence that avian evolution has been influenced by plate tectonics and environmental change, two basic features of Earth's dynamics.
High-Payoff Space Transportation Design Approach with a Technology Integration Strategy
NASA Technical Reports Server (NTRS)
McCleskey, C. M.; Rhodes, R. E.; Chen, T.; Robinson, J.
2011-01-01
A general architectural design sequence is described to create a highly efficient, operable, and supportable design that achieves an affordable, repeatable, and sustainable transportation function. The paper covers the following aspects of this approach in more detail: (1) vehicle architectural concept considerations (including important strategies for greater reusability); (2) vehicle element propulsion system packaging considerations; (3) vehicle element functional definition; (4) external ground servicing and access considerations; and, (5) simplified guidance, navigation, flight control and avionics communications considerations. Additionally, a technology integration strategy is forwarded that includes: (a) ground and flight test prior to production commitments; (b) parallel stage propellant storage, such as concentric-nested tanks; (c) high thrust, LOX-rich, LOX-cooled first stage earth-to-orbit main engine; (d) non-toxic, day-of-launch-loaded propellants for upper stages and in-space propulsion; (e) electric propulsion and aero stage control.
NASA Astrophysics Data System (ADS)
Shokry, A.; Darwish, M. S.; Saad, S. M.; Eldepsy, M.; Zead, I.
2017-08-01
We present the first multicolor CCD photometry for the newly discovered binary system KAO-EGYPT J225702.44+523222.1. New times of light minimum and new ephemeris were obtained. The VR I light curves were analyzed using WD code, the difference in maximum light at phase 0.25 is modeled with a cool spot on the secondary component. The solution show that the system is A-subtype, overcontact binary with fill-out factor = 42% and low mass ratio, q = 0.275. The two components of spectral types K0 and K1 and the primary component is the massive one. The position of both components on the M-L and M-R relations revealed that the primary component is a main sequence star while the secondary is an evolved component.
Brunner, P C; Frey, J E
2010-04-01
Invasions by pest organisms are among the main challenges for sustainable crop protection. They pose a serious threat to crop production by introducing a highly unpredictable element to existing crop protection strategies. The western flower thrips Frankliniella occidentalis (Insecta, Thysanoptera) managed to invade ornamental greenhouses worldwide within < 25 years. To shed light on possible genetic and/or ecological factors that may have been responsible for this invasion success, we studied the population genetic structure of western flower thrips in its native range in western North America. Analysis of nucleotide sequence variation and variation at microsatellite loci revealed the existence of two habitat-specific phylogenetic lineages (ecotypes) with allopatric distribution. One lineage is associated with hot/dry climates, the second lineage is restricted to cool/moist climates. We speculate that the ecological niche segregation found in this study may be among the key factors determining the invasion potential of western flower thrips.
Time-scales of stellar rotational variability and starspot diagnostics
NASA Astrophysics Data System (ADS)
Arkhypov, Oleksiy V.; Khodachenko, Maxim L.; Lammer, Helmut; Güdel, Manuel; Lüftinger, Teresa; Johnstone, Colin P.
2018-01-01
The difference in stability of starspot distribution on the global and hemispherical scales is studied in the rotational spot variability of 1998 main-sequence stars observed by Kepler mission. It is found that the largest patterns are much more stable than smaller ones for cool, slow rotators, whereas the difference is less pronounced for hotter stars and/or faster rotators. This distinction is interpreted in terms of two mechanisms: (1) the diffusive decay of long-living spots in activity complexes of stars with saturated magnetic dynamos, and (2) the spot emergence, which is modulated by gigantic turbulent flows in convection zones of stars with a weaker magnetism. This opens a way for investigation of stellar deep convection, which is yet inaccessible for asteroseismology. Moreover, a subdiffusion in stellar photospheres was revealed from observations for the first time. A diagnostic diagram was proposed that allows differentiation and selection of stars for more detailed studies of these phenomena.
The lithium-rotation connection in the 125 Myr-old Pleiades cluster
NASA Astrophysics Data System (ADS)
Bouvier, J.; Barrado, D.; Moraux, E.; Stauffer, J.; Rebull, L.; Hillenbrand, L.; Bayo, A.; Boisse, I.; Bouy, H.; DiFolco, E.; Lillo-Box, J.; Calderón, M. Morales
2018-06-01
Context. The evolution of lithium abundance over a star's lifetime is indicative of transport processes operating in the stellar interior. Aims: We revisit the relationship between lithium content and rotation rate previously reported for cool dwarfs in the Pleiades cluster. Methods: We derive new LiI 670.8 nm equivalent width measurements from high-resolution spectra obtained for low-mass Pleiades members. We combine these new measurements with previously published ones, and use the Kepler K2 rotational periods recently derived for Pleiades cool dwarfs to investigate the lithium-rotation connection in this 125 Myr-old cluster. Results: The new data confirm the correlation between lithium equivalent width and stellar spin rate for a sample of 51 early K-type members of the cluster, where fast rotating stars are systematically lithium-rich compared to slowly rotating ones. The correlation is valid for all stars over the (J-Ks) color range 0.50-0.70 mag, corresponding to a mass range from about 0.75 to 0.90 M⊙, and may extend down to lower masses. Conclusions: We argue that the dispersion in lithium equivalent widths observed for cool dwarfs in the Pleiades cluster reflects an intrinsic scatter in lithium abundances, and suggest that the physical origin of the lithium dispersion pattern is to be found in the pre-main sequence rotational history of solar-type stars. Based on observations made at Observatoire de Haute Provence (CNRS), France, at the Nordic Optical Telescope (IAC), Spain, and at the W. M. Keck Observatory, Hawaii, USA.Full Table B.1 is only available at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (ftp://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/613/A63
NASA Astrophysics Data System (ADS)
Uysal, Selcuk Can
In this research, MATLAB SimulinkRTM was used to develop a cooled engine model for industrial gas turbines and aero-engines. The model consists of uncooled on-design, mean-line turbomachinery design and a cooled off-design analysis in order to evaluate the engine performance parameters by using operating conditions, polytropic efficiencies, material information and cooling system details. The cooling analysis algorithm involves a 2nd law analysis to calculate losses from the cooling technique applied. The model is used in a sensitivity analysis that evaluates the impacts of variations in metal Biot number, thermal barrier coating Biot number, film cooling effectiveness, internal cooling effectiveness and maximum allowable blade temperature on main engine performance parameters of aero and industrial gas turbine engines. The model is subsequently used to analyze the relative performance impact of employing Anti-Vortex Film Cooling holes (AVH) by means of data obtained for these holes by Detached Eddy Simulation-CFD Techniques that are valid for engine-like turbulence intensity conditions. Cooled blade configurations with AVH and other different external cooling techniques were used in a performance comparison study. (Abstract shortened by ProQuest.).
Ahmadrajabi, Roya; Shakibaie, Mohammad Reza; Iranmanesh, Zahra; Mollaei, Hamid Reza; Sobhanipoor, Mohammad Hossein
2016-07-03
Legionella pneumophila is the primary respiratory pathogen and mostly transmitted to human through water cooling systems and cause mild to severe pneumonia with high mortality rate especially in elderly both in hospitals and community. However, current Legionella risk assessments may be compromised by uncertainties in Legionella detection methods. Here, we investigated the presence of L. pneumophila mip gene in water samples collected from different hospitals cooling towers, nursing homes and building/hotels water coolants from two geographical locations of Iran (Kerman and Bam cities) during summer season of 2015 by both nested and real-time PCR methods. Analysis of the 128 water samples for presence of the mip gene by nested-PCR revealed, 18 (23%) positive cases in Kerman and 7(14%) in Bam. However, when samples were tested by real-time PCR, we identified 4 more new cases of L. pneumophila in the hospitals as well as nursing homes water systems that were missed by nested-PCR. The highest rate of contamination was detected in water obtained from hospitals cooling towers in both the cities (p≤0.05). Dendrogram analysis and clonal relationship by PCR-base sequence typing (SBT) of the L. pneumophila genomic DNAs in Kerman water samples showed close clonal similarities among the isolates, in contrast, isolates identified from Bam city demonstrated two fingerprint patterns. The clones from hospital water samples were more related to the L. pneumophila serogroup- 1.
Ahmadrajabi, Roya; Shakibaie, Mohammad Reza; Iranmanesh, Zahra; Mollaei, Hamid Reza; Sobhanipoor, Mohammad Hossein
2016-01-01
ABSTRACT Legionella pneumophila is the primary respiratory pathogen and mostly transmitted to human through water cooling systems and cause mild to severe pneumonia with high mortality rate especially in elderly both in hospitals and community. However, current Legionella risk assessments may be compromised by uncertainties in Legionella detection methods. Here, we investigated the presence of L. pneumophila mip gene in water samples collected from different hospitals cooling towers, nursing homes and building/hotels water coolants from two geographical locations of Iran (Kerman and Bam cities) during summer season of 2015 by both nested and real-time PCR methods. Analysis of the 128 water samples for presence of the mip gene by nested-PCR revealed, 18 (23%) positive cases in Kerman and 7(14%) in Bam. However, when samples were tested by real-time PCR, we identified 4 more new cases of L. pneumophila in the hospitals as well as nursing homes water systems that were missed by nested-PCR. The highest rate of contamination was detected in water obtained from hospitals cooling towers in both the cities (p≤0.05). Dendrogram analysis and clonal relationship by PCR-base sequence typing (SBT) of the L. pneumophila genomic DNAs in Kerman water samples showed close clonal similarities among the isolates, in contrast, isolates identified from Bam city demonstrated two fingerprint patterns. The clones from hospital water samples were more related to the L. pneumophila serogroup- 1. PMID:27028760
Microstructural and Mechanical Study of Press Hardening of Thick Boron Steel Sheet
NASA Astrophysics Data System (ADS)
Pujante, J.; Garcia-Llamas, E.; Golling, S.; Casellas, D.
2017-09-01
Press hardening has become a staple in the production of automotive safety components, due to the combination of high mechanical properties and form complexity it offers. However, the use of press hardened components has not spread to the truck industry despite the advantages it confers, namely affordable weight reduction without the use of exotic materials, would be extremely attractive for this sector. The main reason for this is that application of press hardened components in trucks implies adapting the process to the manufacture of thick sheet metal. This introduces an additional layer of complexity, mainly due to the thermal gradients inside the material resulting in though-thickness differences in austenitization and cooling, potentially resulting in complex microstructure and gradient of mechanical properties. This work presents a preliminary study on the press hardening of thick boron steel sheet. First of all, the evolution of the sheet metal during austenitization is studied by means of dilatometry tests and by analysing the effect of furnace dwell time on grain size. Afterwards, material cooled using different cooling strategies, and therefore different effective cooling rates, is studied in terms of microstructure and mechanical properties. Initial results from finite element simulation are compared to experimental results, focusing on the phase composition in through thickness direction. Results show that industrial-equivalent cooling conditions do not lead to gradient microstructures, even in extreme scenarios involving asymmetrical cooling.
A Numerical Study of Anti-Vortex Film Cooling Designs at High Blowing Ratio
NASA Technical Reports Server (NTRS)
Heidmann, James D.
2008-01-01
A concept for mitigating the adverse effects of jet vorticity and liftoff at high blowing ratios for turbine film cooling flows has been developed and studied at NASA Glenn Research Center. This "anti-vortex" film cooling concept proposes the addition of two branched holes from each primary hole in order to produce a vorticity counter to the detrimental kidney vortices from the main jet. These vortices typically entrain hot freestream gas and are associated with jet separation from the turbine blade surface. The anti-vortex design is unique in that it requires only easily machinable round holes, unlike shaped film cooling holes and other advanced concepts. The anti-vortex film cooling hole concept has been modeled computationally for a single row of 30deg angled holes on a flat surface using the 3D Navier-Stokes solver Glenn-HT. A modification of the anti-vortex concept whereby the branched holes exit adjacent to the main hole has been studied computationally for blowing ratios of 1.0 and 2.0 and at density ratios of 1.0 and 2.0. This modified concept was selected because it has shown the most promise in recent experimental studies. The computational results show that the modified design improves the film cooling effectiveness relative to the round hole baseline and previous anti-vortex cases, in confirmation of the experimental studies.
Rapid hydrothermal cooling above the axial melt lens at fast-spreading mid-ocean ridge
NASA Astrophysics Data System (ADS)
Zhang, Chao; Koepke, Juergen; Kirchner, Clemens; Götze, Niko; Behrens, Harald
2014-09-01
Axial melt lenses sandwiched between the lower oceanic crust and the sheeted dike sequences at fast-spreading mid-ocean ridges are assumed to be the major magma source of oceanic crust accretion. According to the widely discussed ``gabbro glacier'' model, the formation of the lower oceanic crust requires efficient cooling of the axial melt lens, leading to partial crystallization and crystal-melt mush subsiding down to lower crust. These processes are believed to be controlled by periodical magma replenishment and hydrothermal circulation above the melt lens. Here we quantify the cooling rate above melt lens using chemical zoning of plagioclase from hornfelsic recrystallized sheeted dikes drilled from the East Pacific at the Integrated Ocean Drilling Program Hole 1256D. We estimate the cooling rate using a forward modelling approach based on CaAl-NaSi interdiffusion in plagioclase. The results show that cooling from the peak thermal overprint at 1000-1050°C to 600°C are yielded within about 10-30 years as a result of hydrothermal circulation above melt lens during magma starvation. The estimated rapid hydrothermal cooling explains how the effective heat extraction from melt lens is achieved at fast-spreading mid-ocean ridges.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boegh, P.; Hopkirk, R.; Junod, A.
From international nuclear industries fair; Basel, Switzerland (16 Oct 1972). The extensive environmental studies performed in Switzerland for the cooling towers of the Kaiseraugst and Leibstadt Nuclear Power Plants are presented. The computer program SAUNA for the calculation of the cooling tower plume behavior is briefly described. The main results of the environmental studies are summarized. (8 references) (auth)
ELECTRON MICROSCOPY OF MITOSIS IN AMEBAE
Roth, L. E.
1967-01-01
The mitotic apparatus (MA) of the giant ameba, Chaos carolinensis, has characteristic sequences of microtubule arrays and deployment of nuclear envelope fragments. If mitotic organisms are subjected to 2°C for 5 min, the MA microtubules are completely degraded, and the envelope fragments are released from the chromosomes which remain condensed but lose their metaphase-plate orientation. On warming, microtubules reform but show partial loss of their parallel alignment; displacement of the envelope fragments persists or is increased by microtubule reformation. This study demonstrates that cooling causes destruction of microtubules and intermicrotubular cross-bonds and further shows that such controlled dissolution and reformation can provide an in vivo test sequence for studies on the effects of inhibitor-compounds on microtubule subunit aggregation. Urea, at the comparatively low concentration of 0.8 M, inhibited reformation following cooling and rewarming but was ineffective in altering microtubules that had formed before treatment. PMID:6040537
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Weihuan; France, David M.; Yu, Wenhua
At present, single-phase liquid, forced convection cooled heat sinks with fins are used to cool power electronics in hybrid electric vehicles (HEVs). Although use of fins in the cooling channels increases heat transfer rates considerably, a second low-temperature radiator and associated pumping system are still required in HEVs. This additional cooling system adds weight and cost while decreasing the efficiency of HEVs. With the objective of eliminating this additional low-temperature radiator and pumping system in HEVs, an alternative cooling technology, subcooled boiling in the cooling channels, was investigated in the present study. Numerical heat transfer simulations were performed using subcooledmore » boiling in the power electronics cooling channels with the coolant supplied from the existing main engine cooling system. Results show that this subcooled boiling system is capable of removing 25% more heat from the power electronics than the conventional forced convection cooling technology, or it can reduce the junction temperature of the power electronics at the current heat removal rate. With the 25% increased heat transfer option, high heat fluxes up to 250 W/cm(2) (typical for wideband-gap semiconductor applications) are possible by using the subcooled boiling system.« less
Hemodynamic and thermal responses to head and neck cooling in men and women
NASA Technical Reports Server (NTRS)
Ku, Y. T.; Montgomery, L. D.; Webbon, B. W.
1996-01-01
Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. The objective of this study was to determine the operating characteristics and the physiologic changes produced by short term use of one commercially available thermal control system. A Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used to cool the head and neck regions of 12 female and 12 male subjects (25-55 yr) in this study. The healthy subjects, seated in an upright position at normal room temperature (approximately 21 degrees C), were tested for 30 min with the liquid cooling garment operated at its maximum cooling capacity. Electrocardiograms and scalp and intracranial blood flows were recorded periodically during each test sequence. Scalp, right and left ear, and oral temperatures and cooling system parameters were logged every 5 min. Scalp, right and left ear canal, and oral temperatures were all significantly (P <0.05) reduced by 30 min of head and neck cooling. Oral temperatures decreased approximately 0.2-0.6 degrees C after 30 min and continued to decrease further (approximately 0.1-0.2 degrees C) for a period of approximately 10 min after removal of the cooling helmet. Intracranial blood flow decreased significantly (P < 0.05) during the first 10 min of the cooling period. Both right and left ear temperatures in the women were significantly lower than those of the men during the cooling period. These data indicate that head and neck cooling may be used to reduce core temperature to that needed for symptomatic relief of both male and female multiple sclerosis patients. This study quantifies the operating characteristics of one liquid cooling garment as an example of the information needed to compare the efficiency of other garments operated under different test conditions.
Cooling Models for Old White Dwarfs
NASA Astrophysics Data System (ADS)
Hansen, Brad M. S.
1999-08-01
We present new white dwarf cooling models that incorporate an accurate outer boundary condition based on new opacity and detailed radiative transfer calculations. We find that helium-atmosphere dwarfs cool considerably faster than has previously been claimed, while old hydrogen-atmosphere dwarfs will deviate significantly from blackbody appearance. We use our new models to derive age limits for the Galactic disk. We find that the Liebert, Dahn, & Monet luminosity function yields an age of only 6 Gyr if it is complete to stated limits. However, age estimates of individual dwarfs and the luminosity function of Oswalt et al. are both consistent with disk ages as large as ~11 Gyr. We have also used our models to place constraints on white dwarf dark matter in the Galactic halo. We find that previous attempts using inadequate cooling models were too severe and that direct detection limits allow a halo that is 11 Gyr old. If the halo is composed solely of helium-atmosphere dwarfs, the lower age limit is only 7.5 Gyr. We also demonstrate the importance of studying the cooling sequences of white dwarfs in globular clusters.
Radiative energy balance of the Venus mesosphere
NASA Astrophysics Data System (ADS)
Haus, R.; Goering, H.
1990-03-01
An accurate radiative transfer model for line-by-line gaseous absorption, as well as for cloud absorption and multiple scattering, is used in the present calculation of solar heating and thermal cooling rates for standard temperature profiles and temperatures yielded by the Venera 15 Fourier Spectrometer Experiment. A strong dependency is noted for heating and cooling rates on cloud-structure variations. The Venus mesosphere is characterized by main cloud-cover heating and overlying-haze cooling. These results are applicable to Venus atmosphere dynamical models.
rpiCOOL: A tool for In Silico RNA-protein interaction detection using random forest.
Akbaripour-Elahabad, Mohammad; Zahiri, Javad; Rafeh, Reza; Eslami, Morteza; Azari, Mahboobeh
2016-08-07
Understanding the principle of RNA-protein interactions (RPIs) is of critical importance to provide insights into post-transcriptional gene regulation and is useful to guide studies about many complex diseases. The limitations and difficulties associated with experimental determination of RPIs, call an urgent need to computational methods for RPI prediction. In this paper, we proposed a machine learning method to detect RNA-protein interactions based on sequence information. We used motif information and repetitive patterns, which have been extracted from experimentally validated RNA-protein interactions, in combination with sequence composition as descriptors to build a model to RPI prediction via a random forest classifier. About 20% of the "sequence motifs" and "nucleotide composition" features have been selected as the informative features with the feature selection methods. These results suggest that these two feature types contribute effectively in RPI detection. Results of 10-fold cross-validation experiments on three non-redundant benchmark datasets show a better performance of the proposed method in comparison with the current state-of-the-art methods in terms of various performance measures. In addition, the results revealed that the accuracy of the RPI prediction methods could vary considerably across different organisms. We have implemented the proposed method, namely rpiCOOL, as a stand-alone tool with a user friendly graphical user interface (GUI) that enables the researchers to predict RNA-protein interaction. The rpiCOOL is freely available at http://biocool.ir/rpicool.html for non-commercial uses. Copyright © 2016 Elsevier Ltd. All rights reserved.
A New Sample of Cool Subdwarfs from SDSS: Properties and Kinematics
NASA Astrophysics Data System (ADS)
Savcheva, Antonia; West, Andrew A.; Bochanski, John J.
2014-06-01
We present a new sample of M subdwarfs compiled from the 7th data re- lease of the Sloan Digital Sky Survey. With 3517 new subdwarfs, this new sample significantly increases the number the existing sample of low-mass subdwarfs. This catalog includes unprecedentedly large numbers of extreme and ultra sudwarfs. Here, we present the catalog and the statistical analysis we perform. Subdwarf template spectra are derived. We show color-color and reduced proper motion diagrams of the three metallicity classes, which are shown to separate from the disk dwarf population. The extreme and ultra subdwarfs are seen at larger values of reduced proper motion as expected for more dynamically heated populations. We determine 3D kinematics for all of the stars with proper motions. The color-magnitude diagrams show a clear separation of the three metallicity classes with the ultra and extreme subdwarfs being significantly closer to the main sequence than the ordinary subdwarfs. All subdwarfs lie below and to the blue of the main sequence. Based on the average (U, V, W ) velocities and their dispersions, the extreme and ultra subdwarfs likely belong to the Galactic halo, while the ordinary subdwarfs are likely part of the old Galactic (or thick) disk. An extensive activity analy- sis of subdwarfs is performed using chromospheric Hα emission and 208 active subdwarfs are found. We show that while the activity fraction of subdwarfs rises with spectral class and levels off at the latest spectral classes, consistent with the behavior of M dwarfs, the extreme and ultra subdwarfs are basically flat.
A New Sample of Cool Subdwarfs from SDSS: Properties and Kinematics
NASA Astrophysics Data System (ADS)
Savcheva, Antonia S.; West, Andrew A.; Bochanski, John J.
2014-10-01
We present a new sample of M subdwarfs compiled from the seventh data release of the Sloan Digital Sky Survey. With 3517 new subdwarfs, this new sample significantly increases the number of spectroscopically confirmed low-mass subdwarfs. This catalog also includes 905 extreme and 534 ultra sudwarfs. We present the entire catalog, including observed and derived quantities, and template spectra created from co-added subdwarf spectra. We show color-color and reduced proper motion diagrams of the three metallicity classes, which are shown to separate from the disk dwarf population. The extreme and ultra subdwarfs are seen at larger values of reduced proper motion, as expected for more dynamically heated populations. We determine 3D kinematics for all of the stars with proper motions. The color-magnitude diagrams show a clear separation of the three metallicity classes with the ultra and extreme subdwarfs being significantly closer to the main sequence than the ordinary subdwarfs. All subdwarfs lie below (fainter) and to the left (bluer) of the main sequence. Based on the average (U, V, W) velocities and their dispersions, the extreme and ultra subdwarfs likely belong to the Galactic halo, while the ordinary subdwarfs are likely part of the old Galactic (or thick) disk. An extensive activity analysis of subdwarfs is performed using Hα emission, and 208 active subdwarfs are found. We show that while the activity fraction of subdwarfs rises with spectral class and levels off at the latest spectral classes, consistent with the behavior of M dwarfs, the extreme and ultra subdwarfs are basically flat.
He, Yingdong; Li, Nianping; Wang, Xiang; He, Meiling; He, De
2017-11-17
It is well known that personal cooling improves thermal comfort and save energy. This study aims to: (1) compare different personal cooling systems and (2) understand what influences users' willingness to adopt them. A series of experiments on several types of personal cooling systems, which included physical measurements, questionnaires and feedback, was conducted in a real office environment. The obtained results showed that personal cooling improved comfort of participants in warm environments. Then an improved index was proposed and used to compare different types of personal cooling systems in terms of comfort and energy efficiency simultaneously. According to the improved index, desk fans were highly energy-efficient, while the hybrid personal cooling (the combination of radiant cooling desk and desk fan) consumed more energy but showed advantages of extending the comfortable temperature range. Moreover, if personal cooling was free, most participants were willing to adopt it and the effectiveness was the main factor influencing their willingness, whereas if participants had to pay, they probably refused to adopt it due to the cost and the availability of conventional air conditioners. Thus, providing effective and free personal cooling systems should be regarded as a better way for its wider application.
Spectroscopic investigation of stars on the lower main sequence
NASA Astrophysics Data System (ADS)
Mishenina, T. V.; Soubiran, C.; Bienaymé, O.; Korotin, S. A.; Belik, S. I.; Usenko, I. A.; Kovtyukh, V. V.
2008-10-01
Aims: The aim of this paper is to provide fundamental parameters and abundances with a high accuracy for a large sample of cool main sequence stars. This study is part of wider project, in which the metallicity distribution of the local thin disc is investigated from a complete sample of G and K dwarfs within 25 pc. Methods: The stars were observed at high resolution and a high signal-to-noise ratio with the ELODIE echelle spectrograph. The V sin i were obtained with a calibration of the cross-correlation function. Effective temperatures were estimated by the line depth ratio method. Surface gravities (log g) were determined by two methods: parallaxes and ionization balance of iron. The Mg and Na abundances were derived using a non-LTE approximation. Abundances of other elements were obtained by measuring equivalent widths. Results: Rotational velocities, atmospheric parameters (T_eff, log g, [Fe/H], V_t), and Li, O, Na, Mg, Al, Si, Ca, Sc, Ti, V, Cr, Co, Ni, and Zn abundances are provided for 131 stars. Among them, more than 30 stars are active stars with a fraction of BY Dra and RS CVn type stars for which spectral peculiarities were investigated. We find the mean abundances of the majority of elements in active and nonactive stars to be similar, except for Li, and possibly for Zn and Co. The lithium is reliably detected in 54% of active stars but only in 20% of nonactive stars. No correlation is found between Li abundances and rotational velocities. A possible anticorrelation of log A(Li) with the index of chromospheric activity GrandS is observed. Conclusions: Active and nonactive cool dwarfs show similar dependencies of most elemental ratios vs. [Fe/H]. This allows us to use such abundance ratios to study the chemical and dynamical evolution of the Galaxy. Among active stars, no clear correlation has been found between different indicators of activity for our sample stars. Based on spectra collected with the ELODIE spectrograph at the 1.93-m telescope of the Observatoire de Haute Provence (France). Tables A.1-A3 are only available in electronic form at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsweb.u-strasbg.fr/cgi-bin/qcat?J/A+A/489/923
VizieR Online Data Catalog: NGC 6802 dwarf cluster members and non-members (Tang+, 2017)
NASA Astrophysics Data System (ADS)
Tang, B.; Geisler, D.; Friel, E.; Villanova, S.; Smiljanic, R.; Casey, A. R.; Randich, S.; Magrini, L.; San, Roman I.; Munoz, C.; Cohen, R. E.; Mauro, F.; Bragaglia, A.; Donati, P.; Tautvaisiene, G.; Drazdauskas, A.; Zenoviene, R.; Snaith, O.; Sousa, S.; Adibekyan, V.; Costado, M. T.; Blanco-Cuaresma, S.; Jimenez-Esteban, F.; Carraro, G.; Zwitter, T.; Francois, P.; Jofre, P.; Sordo, R.; Gilmore, G.; Flaccomio, E.; Koposov, S.; Korn, A. J.; Lanzafame, A. C.; Pancino, E.; Bayo, A.; Damiani, F.; Franciosini, E.; Hourihane, A.; Lardo, C.; Lewis, J.; Monaco, L.; Morbidelli, L.; Prisinzano, L.; Sacco, G.; Worley, C. C.; Zaggia, S.
2016-11-01
The dwarf stars in NGC 6802 observed by GIRAFFE spectrograph are separated into four tables: 1. cluster members in the lower main sequence; 2. cluster members in the upper main sequence; 3. non-member dwarfs in the lower main sequence; 4. non-member dwarfs in the upper main sequence. The star coordinates, V band magnitude, V-I color, and radial velocity are given. (4 data files).
New Observational Evidence of Flash Mixing on the White Dwarf Cooling Curve
NASA Technical Reports Server (NTRS)
Brown, T. M.; Lanz, T.; Sweigart, A. V.; Cracraft, Misty; Hubeny, Ivan; Landsman, W. B.
2011-01-01
Blue hook stars are a class of subluminous extreme horizontal branch stars that were discovered in UV images of the massive globular clusters w Cen and NGC 2808. These stars occupy a region of the HR diagram that is unexplained by canonical stellar evolution theory. Using new theoretical evolutionary and atmospheric models, we have shown that the blue hook stars are very likely the progeny of stars that undergo extensive internal mixing during a late helium-core flash on the white dwarf cooling curve. This "flash mixing" produces hotter-than-normal EHB stars with atmospheres significantly enhanced in helium and carbon. The larger bolometric correction, combined with the decrease in hydrogen opacity, makes these stars appear sub luminous in the optical and UV. Flash mixing is more likely to occur in stars born with a high helium abundance, due to their lower mass at the main sequence turnoff. For this reason, the phenomenon is more common in those massive globular clusters that show evidence for secondary populations enhanced in helium. However, a high helium abundance does not, by itself, explain the presence of blue hook stars in massive globular clusters. Here, we present new observational evidence for flash mixing, using recent HST observations. These include UV color-magnitude diagrams of six massive globular clusters and far-UV spectroscopy of hot subdwarfs in one of these clusters (NGC 2808).
Site selection for MSFC operational tests of solar heating and cooling systems
NASA Technical Reports Server (NTRS)
1978-01-01
The criteria, methodology, and sequence aspects of the site selection process are presented. This report organized the logical thought process that should be applied to the site selection process, but final decisions are highly selective.
Challenges of using air conditioning in an increasingly hot climate
NASA Astrophysics Data System (ADS)
Lundgren-Kownacki, Karin; Hornyanszky, Elisabeth Dalholm; Chu, Tuan Anh; Olsson, Johanna Alkan; Becker, Per
2018-03-01
At present, air conditioning (AC) is the most effective means for the cooling of indoor space. However, its increased global use is problematic for various reasons. This paper explores the challenges linked to increased AC use and discusses more sustainable alternatives. A literature review was conducted applying a transdisciplinary approach. It was further complemented by examples from cities in hot climates. To analyse the findings, an analytical framework was developed which considers four societal levels—individual, community, city, and national. The main challenges identified from the literature review are as follows: environmental, organisational, socio-economical, biophysical and behavioural. The paper also identifies several measures that could be taken to reduce the fast growth of AC use. However, due to the complex nature of the problem, there is no single solution to provide sustainable cooling. Alternative solutions were categorised in three broad categories: climate-sensitive urban planning and building design, alternative cooling technologies, and climate-sensitive attitudes and behaviour. The main findings concern the problems arising from leaving the responsibility to come up with cooling solutions entirely to the individual, and how different societal levels can work towards more sustainable cooling options. It is concluded that there is a need for a more holistic view both when it comes to combining various solutions as well as involving various levels in society.
Local cooling and warming effects of forests based on satellite observations.
Li, Yan; Zhao, Maosheng; Motesharrei, Safa; Mu, Qiaozhen; Kalnay, Eugenia; Li, Shuangcheng
2015-03-31
The biophysical effects of forests on climate have been extensively studied with climate models. However, models cannot accurately reproduce local climate effects due to their coarse spatial resolution and uncertainties, and field observations are valuable but often insufficient due to their limited coverage. Here we present new evidence acquired from global satellite data to analyse the biophysical effects of forests on local climate. Results show that tropical forests have a strong cooling effect throughout the year; temperate forests show moderate cooling in summer and moderate warming in winter with net cooling annually; and boreal forests have strong warming in winter and moderate cooling in summer with net warming annually. The spatiotemporal cooling or warming effects are mainly driven by the two competing biophysical effects, evapotranspiration and albedo, which in turn are strongly influenced by rainfall and snow. Implications of our satellite-based study could be useful for informing local forestry policies.
Local cooling and warming effects of forests based on satellite observations
Li, Yan; Zhao, Maosheng; Motesharrei, Safa; Mu, Qiaozhen; Kalnay, Eugenia; Li, Shuangcheng
2015-01-01
The biophysical effects of forests on climate have been extensively studied with climate models. However, models cannot accurately reproduce local climate effects due to their coarse spatial resolution and uncertainties, and field observations are valuable but often insufficient due to their limited coverage. Here we present new evidence acquired from global satellite data to analyse the biophysical effects of forests on local climate. Results show that tropical forests have a strong cooling effect throughout the year; temperate forests show moderate cooling in summer and moderate warming in winter with net cooling annually; and boreal forests have strong warming in winter and moderate cooling in summer with net warming annually. The spatiotemporal cooling or warming effects are mainly driven by the two competing biophysical effects, evapotranspiration and albedo, which in turn are strongly influenced by rainfall and snow. Implications of our satellite-based study could be useful for informing local forestry policies. PMID:25824529
NASA Astrophysics Data System (ADS)
Mekanik, Abolghasem; Soleimani, Mohsen
2007-11-01
Wind effect on natural draught cooling towers has a very complex physics. The fluid flow and temperature distribution around and in a single and two adjacent (tandem and side by side) dry-cooling towers under cross wind are studied numerically in the present work. Cross-wind can significantly reduce cooling efficiency of natural-draft dry-cooling towers, and the adjacent towers can affect the cooling efficiency of both. In this paper we will present a complex computational model involving more than 750,000 finite volume cells under precisely defined boundary condition. Since the flow is turbulent, the standard k-ɛ turbulence model is used. The numerical results are used to estimate the heat transfer between radiators of the tower and air surrounding it. The numerical simulation explained the main reason for decline of the thermo-dynamical performance of dry-cooling tower under cross wind. In this paper, the incompressible fluid flow is simulated, and the flow is assumed steady and three-dimensional.
Plasma arc welding repair of space flight hardware
NASA Technical Reports Server (NTRS)
Hoffman, David S.
1993-01-01
A technique to weld repair the main combustion chamber of Space Shuttle Main Engines has been developed. The technique uses the plasma arc welding process and active cooling to seal cracks and pinholes in the hot-gas wall of the main combustion chamber liner. The liner hot-gas wall is made of NARloy-Z, a copper alloy previously thought to be unweldable using conventional arc welding processes. The process must provide extensive heat input to melt the high conductivity NARloy-Z while protecting the delicate structure of the surrounding material. The higher energy density of the plasma arc process provides the necessary heat input while active water cooling protects the surrounding structure. The welding process is precisely controlled using a computerized robotic welding system.
Film cooling effectiveness and heat transfer with injection through holes
NASA Technical Reports Server (NTRS)
Eriksen, V. L.
1971-01-01
An experimental investigation of the local film cooling effectiveness and heat transfer downstream of injection of air through discrete holes into a turbulent boundary layer of air on a flat plate is reported. Secondary air is injected through a single hole normal to the main flow and through both a single hole and a row of holes spaced at three diameter intervals with an injection angle of 35 deg to the main flow. Two values of the mainstream Reynolds number are used; the blowing rate is varied from 0.1 to 2.0. Photographs of a carbon dioxide-water fog injected into the main flow at an angle of 90 deg are also presented to show interaction between the jet and mainstream.
Effect of cooling rate during hot stamping on low cyclic fatigue of boron steel sheet
NASA Astrophysics Data System (ADS)
Suh, Chang Hee; Jang, Won Seok; Oh, Sang Kyun; Lee, Rac Gyu; Jung, Yun-Chul; Kim, Young Suk
2012-08-01
Boron steel is widely used throughout the automobile industry due to its high tensile strength and hardenability. When boron steel is used for body parts, only high strength is required for crashworthiness. However, when boron steel is used for chassis parts, a high fatigue life is needed. The microstructure of boron steel is mainly affected by the cooling rate during hot stamping. Therefore, this study investigated the low cyclic fatigue life according to the cooling rate. The fatigue life increased at a low strain amplitude when the cooling rate was fast. However, at a high strain amplitude, the fatigue life decreased, due to the low ductility and fracture toughness of the martensite formed by rapid cooling. Martensite formed by a fast cooling rate shows excellent fatigue life at a low total strain amplitude; however, a multiphase microstructure formed by a slow cooling rate is recommended if the parts experience high and low total strain amplitudes alternately. In addition, the cooling rate has little effect on the distribution of solute boron and boron precipitations, so it is expected that boron rarely affects low cyclic fatigue.
Amemura-Maekawa, Junko; Kikukawa, Kiyomi; Helbig, Jürgen H; Kaneko, Satoko; Suzuki-Hashimoto, Atsuko; Furuhata, Katsunori; Chang, Bin; Murai, Miyo; Ichinose, Masayuki; Ohnishi, Makoto; Kura, Fumiaki
2012-06-01
Legionella pneumophila serogroup (SG) 1 is the most frequent cause of legionellosis. This study analyzed environmental isolates of L. pneumophila SG 1 in Japan using monoclonal antibody (MAb) typing and sequence-based typing (SBT). Samples were analyzed from bathwater (BW; n = 50), cooling tower water (CT; n = 50), and soil (SO; n = 35). The distribution of MAb types varied by source, with the most prevalent types being Bellingham (42%), Oxford (72%), and OLDA (51%) in BW, CT, and SO, respectively. The ratios of MAb 3/1 positive isolates were 26, 2, and 14% from BW, CT, and SO, respectively. The environmental isolates from BW, CT, and SO were divided into 34 sequence types (STs; index of discrimination [IOD] = 0.973), 8 STs (IOD = 0.448), and 11 STs (IOD = 0.879), respectively. Genetic variation among CT isolates was smaller than seen in BW and SO. ST1 accounted for 74% of the CT isolates. The only common STs between (i) BW and CT, (ii) BW and SO, and (iii) CT and SO were ST1, ST129, and ST48, respectively, suggesting that each environment constitutes an independent habitat.
Did A Planet Survive A Post-Main Sequence Evolutionary Event?
NASA Astrophysics Data System (ADS)
Sorber, Rebecca; Jang-Condell, Hannah; Zimmerman, Mara
2018-06-01
The GL86 is star system approximately 10 pc away with a main sequence K- type ~ 0.77 M⊙ star (GL 86A) with a white dwarf ~0.49 M⊙ companion (GL86 B). The system has a ~ 18.4 AU semi-major axis, an orbital period of ~353 yrs, and an eccentricity of ~ 0.39. A 4.5 MJ planet orbits the main sequence star with a semi-major axis of 0.113 AU, an orbital period of 15.76 days, in a near circular orbit with an eccentricity of 0.046. If we assume that this planet was formed during the time when the white dwarf was a main sequence star, it would be difficult for the planet to have remained in a stable orbit during the post-main sequence evolution of GL86 B. The post-main sequence evolution with planet survival will be examined by modeling using the program Mercury (Chambers 1999). Using the model, we examine the origins of the planet: whether it formed before or after the post-main sequence evolution of GL86B. The modeling will give us insight into the dynamical evolution of, not only, the binary star system, but also the planet’s life cycle.
McQuarrie, Nadine; Tobgay, Tobgay; Long, Sean P.; Reiners, Peter W.; Cosca, Michael A.
2014-01-01
We link exhumational variability in space and time to the evolving geometry of the Himalayan fold–thrust belt in western Bhutan. By combining new and published geochronologic and thermochronologic data we document the burial age, peak temperatures and complete cooling history from 20 Ma to the present over an across-strike distance of ∼125 km. These integrated cooling curves highlight windows of fast exhumation that vary spatially and temporally. We propose that pulses of fast exhumation are a result of structures that facilitate the vertical motion of material, illustrated in sequentially-restored cross sections. Due to a range of permissible geometries at depth, we explore and evaluate the impact of geometry on kinematics and rates of deformation. The linked cooling history and cross sections provide estimates of both magnitude and timing of thrust sheet displacement and highlight temporal variability in potential shortening rates. Structural and chronologic data illustrate a general north to south progression of Himalayan deformation, with emplacement of the Main Central thrust (MCT), Paro thrust and Shumar thrust by 12 to no later than 9 Ma. Two different geometries and kinematic scenarios for the Lesser Himalayan duplex are proposed. A north to south propagating duplex system requires that the southern portion of that system, south of the MCT, deformed and cooled by 9 Ma, leaving only the southernmost thrust sheets, including the Main Boundary and Main Frontal thrusts, to deform between 9 and 0 Ma. This limited post 9 Ma shortening would necessitate a marked slowdown in convergence accommodated on the Main Himalayan thrust. A two-tiered duplex system, which allows for the Paro window duplex and the southern Baxa duplex to form simultaneously, permits duplex formation and accompanying exhumation until 6 Ma. Limited cooling from ∼200 °C to the surface post 6 Ma suggests either a decrease in shortening rates from 6 to 0 Ma or that duplex formation and exhumation are temporally decoupled. Our combined cooling curves highlight that the youngest cooling ages may not mark the fastest thrusting rates or the window of fastest exhumation. Instead, temporal variations in exhumation are best viewed through identifying transients in exhumation rate. We suggest that the strongest control on exhumation magnitude and variability is fold–thrust belt geometry, particularly the locations and magnitudes of footwall ramps, which can change over 10ʼs of km distance. Balanced cross sections predict the location and magnitude of these ramps and how they vary in space and time, providing an untapped potential for testing permissible cross-section geometries and kinematics against measured cooling histories.
The frequency of planetary debris around young white dwarfs
NASA Astrophysics Data System (ADS)
Koester, D.; Gänsicke, B. T.; Farihi, J.
2014-06-01
Context. Heavy metals in the atmospheres of white dwarfs are thought in many cases to be accreted from a circumstellar debris disk, which was formed by the tidal disruption of a rocky planetary body within the Roche radius of the star. The abundance analysis of photospheric elements and conclusions about the chemical composition of the accreted matter are a new and promising method of studying the composition of extrasolar planetary systems. However, ground-based searches for metal-polluted white dwarfs that rely primarily on the detection of the Ca ii K line become insensitive at Teff > 15 000 K because this ionization state depopulates. Aims: We present the results of the first unbiased survey for metal pollution among hydrogen-atmosphere (DA type) white dwarfs with cooling ages in the range 20-200 Myr and 17 000 K
NASA Astrophysics Data System (ADS)
Bornstein, R. D.; Lebassi, B.; Gonzalez, J.
2010-12-01
The study evaluated long-term (1948-2005) air temperatures at over 300 urban and rural sites in California (CA) during summer (June-August, JJA). The aggregate CA results showed asymmetric warming, as daily min temperatures increased faster than daily max temperatures. The spatial distributions of daily max temperatures in the heavily urbanized South Coast and San Francisco Bay Area air basins, however, exhibited a complex pattern, with cooling at low-elevation (mainly urban) coastal-areas and warming at (mainly rural) inland areas. Previous studies have suggested that cooling summer max temperatures in CA were due to increased irrigation, coastal upwelling, or cloud cover. The current hypothesis, however, is that this temperature pattern arises from a “reverse-reaction” to greenhouse gas (GHG) induced global-warming. In this hypothesis, the global warming of inland areas resulted in an increased (cooling) sea breeze activity in coastal areas. That daytime summer coastal cooling was seen in coastal urban areas implies that urban heat island (UHI) warming was weaker than the reverse-reaction sea breeze cooling; if there was no UHI effect, then the cooling would have been even stronger. Analysis of daytime summer max temperatures at four adjacent pairs of urban and rural sites near the inland cooling-warming boundary, however, showed that the rural sites experienced cooling, while the urban sites showed warming due to UHI development. The rate of heat island growth was estimated as the sum of each urban warming rate and the absolute magnitude of the concurrent adjacent rural cooling rate. Values ranged from 0.12 to 0.55 K decade-1, and were proportional to changes in urban population and urban extent. As Sacramento, Modesto, Stockton, and San José have grown in aerial extent (21 to 59%) and population (40 to 118%), part of the observed increased JJA max values could be due to increased daytime UHI-intensity. Without UHI effects, the currently observed JJA SFBA coastal-cooling area might have expanded to include these sites, as the first three are adjacent to rural airport sites that showed cooling max-values due to increased marine influences. In addition, all urbanized sites with decreasing max-values would probably show even larger cooling rates if UHI effects could be removed. Significant societal impacts may result from this observed reverse-reaction to GHG-warming. Possible beneficial effects (especially during periods of UHI growth) include decreased maximum: O3 levels, per-capita energy requirements for cooling, and human thermal-stress levels.
Legionella detection and subgrouping in water air-conditioning cooling tower systems in Kuwait.
Al-Matawah, Qadreyah; Al-Zenki, Sameer; Al-Azmi, Ahmad; Al-Waalan, Tahani; Al-Salameen, Fadila; Hejji, Ahmad Ben
2015-07-01
The main aim of the study was to test for the presence of Legionnaires' disease-causing microorganisms in air-conditioned buildings in Kuwait using molecular technologies. For this purpose, 547 samples were collected from 38 cooling towers for the analysis of Legionella pneumophila. These samples included those from water (n = 178), air (n = 231), and swabs (n = 138). Out of the 547 samples, 226 (41%) samples were presumptive positive for L. pneumophila, with L. pneumophila viable counts in the positive water samples ranging from 1 to 88 CFU/ml. Of the Legionella culture-positive samples, 204 isolates were examined by latex agglutination. These isolates were predominately identified as L. pneumophila serogroup (sg) 2-14. Using the Dresden panel of monoclonal antibodies, 74 representatives isolates were further serogrouped. Results showed that 51% of the isolates belonged to serogroup 7 followed by 1 (18%) and 3 (18%). Serogroups 4 (4%) and 10 (7%) were isolated at a lower frequency, and two isolates could not be assigned to a serogroup. These results indicate the wide prevalence of L. pneumophila serogroup 7 as the predominant serogroup at the selected sampling sites. Furthermore, the 74 L. pneumophila (sg1 = 13; sg3 = 13; sg4 = 3; sg7 = 38; sg10 = 5; sgX = 2) isolates were genotyped using the seven gene protocol sequence-based typing (SBT) scheme developed by the European Working Group for Legionella Infections (EWGLI). The results show that Legionella isolates were discriminated into nine distinct sequence typing (ST) profiles, five of which were new to the SBT database of EWGLI. Additionally, all of the ST1 serogroup 1 isolates were of the OLDA/Oxford subgroup. These baseline data will form the basis for the development of a Legionella environmental surveillance program and used for future epidemiological investigations.
Huttunen-Saarivirta, E; Rajala, P; Marja-Aho, M; Maukonen, J; Sohlberg, E; Carpén, L
2018-04-01
In this work, six common stainless steel grades were compared with respect to ennoblement characteristics, corrosion performance and tendency to biofouling in brackish sea water in a pilot-scale cooling water circuit. Two tests were performed, each employing three test materials, until differences between the materials were detected. Open circuit potential (OCP) was measured continuously in situ. Potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) measurements were conducted before and after the tests. Exposed specimens were further subjected to examinations by scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS), and the biofouling was studied using epifluorescence microscopy, quantitative polymerase chain reaction (qPCR) and high-throughput sequencing (HTP sequencing). The results revealed dissimilarities between the stainless steel grades in corrosion behaviour and biofouling tendency. The test material that differed from the most of the other studied alloys was grade EN 1.4162. It experienced fastest and most efficient ennoblement of OCP, its passive area shrank to the greatest extent and the cathodic reaction was accelerated to a significant degree by the development of biofilm. Furthermore, microbiological analyses revealed that bacterial community on EN 1.4162 was dominated by Actinobacteria, whereas on the other five test materials Proteobacteria was the main bacterial phylum. Copyright © 2017 Elsevier B.V. All rights reserved.
Vavilov, A Iu; Viter, V I
2007-01-01
Mathematical questions of data errors of modern thermometrical models of postmortem cooling of the human body are considered. The main diagnostic areas used for thermometry are analyzed to minimize these data errors. The authors propose practical recommendations to decrease data errors of determination of prescription of death coming.
The feasibility of solar energy usage on Red River Army Depot. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crowder, G.W.
This feasibility study considers the usage of solar energy to heat and cool the main office buildings on the Red River Army Depot, Texarkana Texas. Solar energy costs are compared with the present heating and cooling system costs with an economic analysis using the annual worth and present worth methods. (GRA)
He, Yingdong; Li, Nianping; Wang, Xiang; He, Meiling; He, De
2017-01-01
It is well known that personal cooling improves thermal comfort and save energy. This study aims to: (1) compare different personal cooling systems and (2) understand what influences users’ willingness to adopt them. A series of experiments on several types of personal cooling systems, which included physical measurements, questionnaires and feedback, was conducted in a real office environment. The obtained results showed that personal cooling improved comfort of participants in warm environments. Then an improved index was proposed and used to compare different types of personal cooling systems in terms of comfort and energy efficiency simultaneously. According to the improved index, desk fans were highly energy-efficient, while the hybrid personal cooling (the combination of radiant cooling desk and desk fan) consumed more energy but showed advantages of extending the comfortable temperature range. Moreover, if personal cooling was free, most participants were willing to adopt it and the effectiveness was the main factor influencing their willingness, whereas if participants had to pay, they probably refused to adopt it due to the cost and the availability of conventional air conditioners. Thus, providing effective and free personal cooling systems should be regarded as a better way for its wider application. PMID:29149078
South side. Also showing forebay, wing for the main control ...
South side. Also showing forebay, wing for the main control room, and evaporative cooling unit at left - Wellton-Mohawk Irrigation System, Pumping Plant No. 2, Bounded by Interstate 8 to south, Wellton, Yuma County, AZ
A Numerical Analysis of Heat Transfer and Effectiveness on Film Cooled Turbine Blade Tip Models
NASA Technical Reports Server (NTRS)
Ameri, A. A.; Rigby, D. L.
1999-01-01
A computational study has been performed to predict the distribution of convective heat transfer coefficient on a simulated blade tip with cooling holes. The purpose of the examination was to assess the ability of a three-dimensional Reynolds-averaged Navier-Stokes solver to predict the rate of tip heat transfer and the distribution of cooling effectiveness. To this end, the simulation of tip clearance flow with blowing of Kim and Metzger was used. The agreement of the computed effectiveness with the data was quite good. The agreement with the heat transfer coefficient was not as good but improved away from the cooling holes. Numerical flow visualization showed that the uniformity of wetting of the surface by the film cooling jet is helped by the reverse flow due to edge separation of the main flow.
NASA Astrophysics Data System (ADS)
Warren, Clare J.; Singh, Athokpam K.; Roberts, Nick M. W.; Regis, Daniele; Halton, Alison M.; Singh, Rajkumar B.
2014-07-01
The Zimithang Thrust juxtaposes two lithotectonic units of the Greater Himalayan Sequence in Arunachal Pradesh, NE India. Monazite U-Pb, muscovite 40Ar/39Ar and thermobarometric data from rocks in the hanging and footwall constrain the timing and conditions of their juxtaposition across the structure, and their subsequent cooling. Monazite grains in biotite-sillimanite gneiss in the hanging wall yield LA-ICP-MS U-Pb ages of 16 ± 0.2 to 12.7 ± 0.4 Ma. A schistose gneiss within the high strain zone yields overlapping-to-younger monazite ages of 14.9 ± 0.3 to 11.5 ± 0.3 Ma. Garnet-staurolite-mica schists in the immediate footwall yield older monazite ages of 27.3 ± 0.6 to 17.1 ± 0.2 Ma. Temperature estimates from Ti-in-biotite and garnet-biotite thermometry suggest similar peak temperatures were achieved in the hanging and footwalls (~ 525-650 °C). Elevated temperatures of ~ 700 °C appear to have been reached in the high strain zone itself and in the footwall further from the thrust. Single grain fusion 40Ar/39Ar muscovite data from samples either side of the thrust yield ages of ~ 7 Ma, suggesting that movement along the thrust juxtaposed the two units by the time the closure temperature of Ar diffusion in muscovite had been reached. These data confirm previous suggestions that major orogen-parallel out-of-sequence structures disrupt the Greater Himalayan Sequence at different times during Himalayan evolution, and highlight an eastwards-younging trend in 40Ar/39Ar muscovite cooling ages at equivalent structural levels along Himalayan strike.
Streakline flow visualization of discrete hole film cooling with holes inclined 30 deg to surface
NASA Technical Reports Server (NTRS)
Colladay, R. S.; Russell, L. M.; Lane, J. M.
1976-01-01
Film injection from three rows of discrete holes angled 30 deg to the surface in line with mainstream flow and spaced 5 diameters apart in a staggered array was visualized by using helium bubbles as tracer particles. Both the main stream and the film injectant were ambient air. Detailed streaklines showing the turbulent motion of the film mixing with the main stream were obtained by photographing small, neutrally buoyant helium-filled soap bubbles which followed the flow field. The ratio of boundary layer thickness to hole diameter and the Reynolds number were typical of gas turbine film cooling applications. The results showed the behavior of the film and its interaction with the main stream for a range of blowing rates and two initial boundary layer thicknesses.
Dry coolers and air-condensing units (Review)
NASA Astrophysics Data System (ADS)
Milman, O. O.; Anan'ev, P. A.
2016-03-01
The analysis of factors affecting the growth of shortage of freshwater is performed. The state and dynamics of the global market of dry coolers used at electric power plants are investigated. Substantial increase in number and maximum capacity of air-cooled condensers, which have been put into operation in the world in recent years, are noted. The key reasons facilitating the choice of developers of the dry coolers, in particular the independence of the location of thermal power plant from water sources, are enumerated. The main steam turbine heat removal schemes using air cooling are considered, their comparison of thermal efficiency is assessed, and the change of three important parameters, such as surface area of heat transfer, condensate pump flow, and pressure losses in the steam exhaust system, are estimated. It is shown that the most effective is the scheme of direct steam condensation in the heat-exchange tubes, but other schemes also have certain advantages. The air-cooling efficiency may be enhanced much more by using an air-cooling hybrid system: a combination of dry and wet cooling. The basic applied constructive solutions are shown: the arrangement of heat-exchange modules and the types of fans. The optimal mounting design of a fully shopassembled cooling system for heat-exchange modules is represented. Different types of heat-exchange tubes ribbing that take into account the operational features of cooling systems are shown. Heat transfer coefficients of the plants from different manufacturers are compared, and the main reasons for its decline are named. When using evaporative air cooling, it is possible to improve the efficiency of air-cooling units. The factors affecting the faultless performance of dry coolers (DC) and air-condensing units (ACU) and the ways of their elimination are described. A high velocity wind forcing reduces the efficiency of cooling systems and creates preconditions for the development of wind-driven devices. It is noted that global trends have a significant influence on the application of dry coolers in Russia, in view of the fact that some TPP have a surface condensers arrangement. The reasons that these systems are currently less efficient than the direct steam condensation in an air-cooled condenser are explained. It is shown that, in some cases, it is more reasonable to use mixing-type condensers in combination with a dry cooler. Measures for a full import substitution of steam exhaust heat removal systems are mentioned.
Closeup view looking into the nozzle of the Space Shuttle ...
Close-up view looking into the nozzle of the Space Shuttle Main Engine number 2061 looking at the cooling tubes along the nozzle wall and up towards the Main Combustion Chamber and Injector Plate - Space Transportation System, Space Shuttle Main Engine, Lyndon B. Johnson Space Center, 2101 NASA Parkway, Houston, Harris County, TX
Expert systems for fault diagnosis in nuclear reactor control
NASA Astrophysics Data System (ADS)
Jalel, N. A.; Nicholson, H.
1990-11-01
An expert system for accident analysis and fault diagnosis for the Loss Of Fluid Test (LOFT) reactor, a small scale pressurized water reactor, was developed for a personal computer. The knowledge of the system is presented using a production rule approach with a backward chaining inference engine. The data base of the system includes simulated dependent state variables of the LOFT reactor model. Another system is designed to assist the operator in choosing the appropriate cooling mode and to diagnose the fault in the selected cooling system. The response tree, which is used to provide the link between a list of very specific accident sequences and a set of generic emergency procedures which help the operator in monitoring system status, and to differentiate between different accident sequences and select the correct procedures, is used to build the system knowledge base. Both systems are written in TURBO PROLOG language and can be run on an IBM PC compatible with 640k RAM, 40 Mbyte hard disk and color graphics.
Main photoautotrophic components of biofilms in natural draft cooling towers.
Hauer, Tomáš; Čapek, Petr; Böhmová, Petra
2016-05-01
While photoautotrophic organisms are an important component of biofilms that live in certain regions of natural draft cooling towers, little is known about these communities. We therefore examined 18 towers at nine sites to identify the general patterns of community assembly in three distinct tower parts, and we examined how community structures differ depending on geography. We also compared the newly acquired data with previously published data. The bottom sections of draft cooling towers are mainly settled by large filamentous algae, primarily Cladophora glomerata. The central portions of towers host a small amount of planktic algae biomass originating in the cooling water. The upper fourths of towers are colonized by biofilms primarily dominated by cyanobacteria, e.g., members of the genera Gloeocapsa and Scytonema. A total of 41 taxa of phototrophic microorganisms were identified. Species composition of the upper fourth of all towers was significantly affected by cardinal position. There was different species composition at positions facing north compared to positions facing south. West- and east-facing positions were transitory and highly similar to each other in terms of species composition. Biofilms contribute to the degradation of paint coatings inside towers.
Thermosensory processing in the Drosophila brain
Liu, Wendy W.; Mazor, Ofer; Wilson, Rachel I.
2014-01-01
In Drosophila, just as in vertebrates, changes in external temperature are encoded by bidirectional opponent thermoreceptor cells: some cells are excited by warming and inhibited by cooling, whereas others are excited by cooling and inhibited by warming1,2. The central circuits that process these signals are not understood. In Drosophila, a specific brain region receives input from thermoreceptor cells2,3. Here we show that distinct genetically-identified projection neurons (PNs) in this brain region are excited by cooling, warming, or both. The PNs excited by cooling receive mainly feedforward excitation from cool thermoreceptors. In contrast, the PNs excited by warming (“warm-PNs”) receive both excitation from warm thermoreceptors and crossover inhibition from cool thermoreceptors via inhibitory interneurons. Notably, this crossover inhibition elicits warming-evoked excitation, because warming suppresses tonic activity in cool thermoreceptors. This in turn disinhibits warm-PNs and sums with feedforward excitation evoked by warming. Crossover inhibition could cancel non-thermal activity (noise) that is positively-correlated among warm and cool thermoreceptor cells, while reinforcing thermal activity which is anti-correlated. Our results show how central circuits can combine signals from bidirectional opponent neurons to construct sensitive and robust neural codes. PMID:25739502
Holocene climate dynamics in the central part of the East European plain (Russia)
NASA Astrophysics Data System (ADS)
Novenko, Elena
2013-04-01
The Holocene climate and vegetation dynamics in the broad-leaved forest zone of the central part of the East European plain have been reconstructed on the base of pollen, plant macrofossil, testate amoebae and radiocarbon data from the mire Klukva (N 53.834812, E 36.252488), located in the kast depression in the Upper Oka River basin (Tula region, European Russia). The reconstruction of main parameters of past climate (the mean annual temperature precipitation) was carried out by the "Best Modern Analog" approach. Reconstructions of vegetation show that in the early Holocene the territory was occupied mainly by birch and pine-birch forests. Significant changes in the plant cover of the Upper Oka River basin are attributed to the 7.5 cal kyr BP). The climatic conditions were favorable for development of the broad-leaved forests those persisted in this area up to industrial period. In the 17th century, when the population density greatly increased and watersheds were ploughed, natural vegetation communities were gradually destroyed and transformed into agricultural landscapes. According to obtained climatic reconstructions the period 10-8.5 cal kyr BP was relatively cold and wet, when the mean annual temperature was in 3°C lower and precipitation was in 50-100 mm higher then nowadays. The significant climate warming occurred in about 7.0-5.0 cal kyr BP (The Holocene thermal maximum): the mean annual temperature in 2°C exceeded the modern value and precipitation was close to that. The environment conditions were drier due to decrease of effective moisture. In the second part of the Holocene the sequence of second-, and even third-order climatic oscillations expressed against the background of the overall slight trend towards cooling have been determined. The most pronounced cool and wet intervals were reconstructed in 2.5-2.0 cal kyr BP and 1.5-1.3 cal kyr BP. The mean annual temperature decreased in 1.5-2 °C and precipitation rose in 200 mm in compare to modern ones. During the last millennium the warming of the Medieval Climatic Anomaly and cooling of the Little Ice Age were clearly determined. This work was supported by RFBR grant 11-05-00557.
ACCELERATORS: RF system design and measurement of HIRF-CSRe
NASA Astrophysics Data System (ADS)
Xu, Zhe; Zhao, Hong-Wei; Wang, Chun-Xiao; Xia, Jia-Wen; Zhan, Wen-Long; Bian, Zhi-Bin
2009-05-01
An RF system for the CSRe (cooling storage experimental ring) is designed and manufactured domestically. The present paper mainly describes the RF system design in five main sections: ferrite ring, RF cavity, RF generator, low level system and cavity cooling. The cavity is based on a type of coaxial resonator which is shorted at the end with one gap and loaded with domestic ferrite rings. The RF generator is designed in the push-pull mode and the low level control system is based on a DSP+FGPA+DDS+USB interface and has three feedback loops. Finally we give the results of the measurement on our system.
NASA Technical Reports Server (NTRS)
Colladay, R. S.; Russell, L. M.
1976-01-01
Film injection from discrete holes in a three-row, staggered array with five-diameter spacing was studied for three hole angles: (1) normal, (2) slanted 30 deg to the surface in the direction of the main stream, and (3) slanted 30 deg to the surface and 45 deg laterally to the main stream. The ratio of the boundary layer thickness-to-hole diameter and Reynolds number were typical of gas-turbine film-cooling applications. Detailed streaklines showing the turbulent motion of the injected air were obtained by photographing very small neutrally buoyant, helium-filled soap bubbles which follow the flow field.
EPA and USDA to Help Two Maine Communities with Economic Development Goals
The U.S. Environmental Protection Agency and the U.S. Department of Agriculture have selected Eastport & Millinocket, Maine, as partners in Cool & Connected, an innovative initiative that helps small towns use broadband service for economic development.
Time Variability of the Dust Sublimation Zones in Pre-Main Sequence Disk Systems
NASA Technical Reports Server (NTRS)
Sitko, Michael L.; Carpenter, W. J.; Grady, C. A.; Russel, R. W.; Lynch, D. K.; Rudy, R. J.; Mazuk, S. M.; Venturini, C. C.; Kimes, R. L.; Beerman, L. C.;
2007-01-01
The dust sublimation zone (DSZ) is the region of pre-main sequence (PMS) disks where dust grains most easily anneal, sublime, and condense out of the gas. Because of this, it is a location where crystalline material may be enhanced and redistributed throughout the rest of the disk. A decade-long program to monitor the thermal emission of the grains located in this region demonstrates that large changes in emitted flux occur in many systems. Changes in the thermal emission between 3 and 13.5 microns were observed in HD 31648 (MWC 480), HD 163296 (MWC 275), and DG Tau. This emission is consistent with it being produced at the DSZ, where the transition from a disk of gas to one of gas+dust occurs. In the case of DG Tau, the outbursts were accompanied by increased emission on the 10 micron silicate band on one occasion, while on another occasion it went into absorption. This requires lofting of the material above the disk into the line of sight. Such changes will affect the determination of the inner disk structure obtained through interferometry measurements, and this has been confirmed in the case of HD 163296. Cyclic variations in the heating of the DSZ will lead to the annealing of large grains, the sublimation of smaller grains, possibly followed by re-condensation as the zone enters a cooling phase. Lofting of dust above the disk plane, and outward acceleration by stellar winds and radiation pressure, can re-distribute the processed material to cooler regions of the disk, where cometesimals form. This processing is consistent with the detection of the preferential concentration of large crystalline grains in the inner few AU of PMS disks using interferometric spectroscopy with the VLTI.
Very Low Mass Stars with Extremely Low Metallicity in the Milky Way's Halo
NASA Astrophysics Data System (ADS)
Aoki, Wako; Beers, Timothy C.; Takuma, Suda; Honda, Satoshi; Lee, Young Sun
2015-08-01
Large surveys and follow-up spectroscopic studies in the past few decades have been providing chemical abundance data for a growing number of very metal-poor ([Fe/H] <-2) stars. Most of them are red giants or main-sequence turn-off stars having masses near 0.8 solar masses. Lower mass stars with extremely low metallicity ([Fe/H] <-3) have yet to be well explored. Our high-resolution spectroscopic study for very metal-poor stars found with SDSS has identified four cool main-sequence stars with [Fe/H] <-2.5 among 137 objects (Aoki et al. 2013, AJ, 145, 13). The effective temperatures of these stars are 4500--5000 K, corresponding to a mass of around 0.5 solar masses. Our standard analysis of the high-resolution spectra based on 1D-LTE model atmospheres have obtained self-consistent chemical abundances for these objects, assuming small values of micro-turbulent velocities compared with giants and turn-off stars. The low temperature of the atmospheres of these objects enables us to measure their detailed chemical abundances. Interestingly, two of the four stars have extreme chemical abundance patterns: one has the largest excesses of heavy neutron-capture elements associated with the r-process abundance pattern known to date (Aoki et al. 2010, ApJL 723, L201), and the other exhibits low abundances of the alpha-elements and odd-Z elements, suggested to be the signatures of the yields of very massive stars ( >100 solar masses; Aoki et al. 2014, Science 345, 912). Although the sample size is still small, these results indicate the potential of very low-mass stars as probes to study the early stages of the Milky Way's halo formation.
Very Low-Mass Stars with Extremely Low Metallicity in the Milky Way's Halo
NASA Astrophysics Data System (ADS)
Aoki, Wako; Beers, Timothy C.; Suda, Takuma; Honda, Satoshi; Lee, Young Sun
2016-08-01
Large surveys and follow-up spectroscopic studies in the past few decades have been providing chemical abundance data for a growing number of very metal-poor ([Fe/H] <-2) stars. Most of them are red giants or main-sequence turn-off stars having masses near 0.8 solar masses. Lower mass stars with extremely low metallicity ([Fe/H] <-3) are yet to be explored. Our high-resolution spectroscopic study for very metal-poor stars found with SDSS has identified four cool main-sequence stars with [Fe/H] <-2.5 among 137 objects (Aoki et al. 2013). The effective temperatures of these stars are 4500-5000 K, corresponding to a mass of around 0.5 solar masses. Our standard analysis of the high-resolution spectra based on 1D-LTE model atmospheres has obtained self-consistent chemical abundances for these objects, assuming small values of micro-turbulent velocities compared with giants and turn-off stars. The low temperature of the atmospheres of these objects enables us to measure their detailed chemical abundances. Interestingly, two of the four stars have extreme chemical-abundance patterns: one has the largest excesses of heavy neutron-capture elements associated with the r-process abundance pattern known to date (Aoki et al. 2010), and the other exhibits low abundances of the α-elements and odd-Z elements, suggested to be signatures of the yields of very massive stars (> 100 solar masses; Aoki et al. 2014). Although the sample size is still small, these results indicate the potential of very low-mass stars as probes to study the early stages of the Milky Way's halo formation.
NASA Astrophysics Data System (ADS)
Kotnig, C.; Tavian, L.; Brenn, G.
2017-12-01
The cooling of the superconducting magnet cold masses with superfluid helium (He II) is a well-established concept successfully in operation for years in the LHC. Consequently, its application for the cooling of FCC magnets is an obvious option. The 12-kW heat loads distributed over 10-km long sectors not only require an adaption of the magnet bayonet heat exchangers but also present new challenges to the cryogenic plants, the distribution system and the control strategy. This paper recalls the basic LHC cooling concept with superfluid helium and defines the main parameters for the adaption to the FCC requirements. Pressure drop and hydrostatic head are developed in the distribution and pumping systems; their impact on the magnet temperature profile and the corresponding cooling efficiency is presented and compared for different distribution and pumping schemes.
Two-stage crossed beam cooling with ⁶Li and ¹³³Cs atoms in microgravity.
Luan, Tian; Yao, Hepeng; Wang, Lu; Li, Chen; Yang, Shifeng; Chen, Xuzong; Ma, Zhaoyuan
2015-05-04
Applying the direct simulation Monte Carlo (DSMC) method developed for ultracold Bose-Fermi mixture gases research, we study the sympathetic cooling process of 6Li and 133Cs atoms in a crossed optical dipole trap. The obstacles to producing 6Li Fermi degenerate gas via direct sympathetic cooling with 133Cs are also analyzed, by which we find that the side-effect of the gravity is one of the main obstacles. Based on the dynamic nature of 6Li and 133Cs atoms, we suggest a two-stage cooling process with two pairs of crossed beams in microgravity environment. According to our simulations, the temperature of 6Li atoms can be cooled to T = 29.5 pK and T/TF = 0.59 with several thousand atoms, which propose a novel way to get ultracold fermion atoms with quantum degeneracy near pico-Kelvin.
Evaluation of two cooling systems under a firefighter coverall.
Teunissen, Lennart P J; Wang, Li-Chu; Chou, Shih-Nung; Huang, Chin-Hsien; Jou, Gwo-Tsuen; Daanen, Hein A M
2014-11-01
Firemen often suffer from heat strain. This study investigated two chest cooling systems for use under a firefighting suit. In nine male subjects, a vest with water soaked cooling pads and a vest with water perfused tubes were compared to a control condition. Subjects performed 30 min walking and 10 min recovery in hot conditions, while physiological and perceptual parameters were measured. No differences were observed in heart rate and rectal temperature, but scapular skin temperature and fluid loss were lower using the perfused vest. Thermal sensation was cooler for the perfused vest than for the other conditions, while the cool pad vest felt initially cooler than control. However, comfort and RPE scores were similar. We conclude that the cooling effect of both tested systems, mainly providing a (temporally) cooler thermal sensation, was limited and did not meet the expectations. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Simple sequence repeat markers for interspecific hybrid detections in Agrostis
USDA-ARS?s Scientific Manuscript database
Agrostis stolonifera L. (creeping bentgrass) and Agrostis capillaris (colonial bentgrass) are turfgrass species that are well adapted for golf course use in regions of the world where cool-season grasses are grown. Interspecific hybrids between the species do form and have the potential to incorpora...
Kikukawa, Kiyomi; Helbig, Jürgen H.; Kaneko, Satoko; Suzuki-Hashimoto, Atsuko; Furuhata, Katsunori; Chang, Bin; Murai, Miyo; Ichinose, Masayuki; Ohnishi, Makoto; Kura, Fumiaki
2012-01-01
Legionella pneumophila serogroup (SG) 1 is the most frequent cause of legionellosis. This study analyzed environmental isolates of L. pneumophila SG 1 in Japan using monoclonal antibody (MAb) typing and sequence-based typing (SBT). Samples were analyzed from bathwater (BW; n = 50), cooling tower water (CT; n = 50), and soil (SO; n = 35). The distribution of MAb types varied by source, with the most prevalent types being Bellingham (42%), Oxford (72%), and OLDA (51%) in BW, CT, and SO, respectively. The ratios of MAb 3/1 positive isolates were 26, 2, and 14% from BW, CT, and SO, respectively. The environmental isolates from BW, CT, and SO were divided into 34 sequence types (STs; index of discrimination [IOD] = 0.973), 8 STs (IOD = 0.448), and 11 STs (IOD = 0.879), respectively. Genetic variation among CT isolates was smaller than seen in BW and SO. ST1 accounted for 74% of the CT isolates. The only common STs between (i) BW and CT, (ii) BW and SO, and (iii) CT and SO were ST1, ST129, and ST48, respectively, suggesting that each environment constitutes an independent habitat. PMID:22492442
FUSE Cycle 3 Program CO22: Chromospheric Activity in Population II Giants
NASA Technical Reports Server (NTRS)
Harper, Graham M.
2004-01-01
One of the mysteries of Population II giants is that they still show chromospheric emission despite their great age. The global dynamo which was active during their main-sequence lifetimes is expected to become extremely weak through magnetic rotational braking. The nature of the observed emission is not understood; although acoustic shock waves might provide the heating, acoustic waves are not predicted to drive the observed mass loss - which in turn requires the dissipation of magneto-hydrodynamic waves. This program was designed to search for the faint stellar H Ly(beta) emission wings and the fluorescent Fe II and H2 emission from one of the brightest, metal poor, Population II stars. These FUSE diagnostics, when combined with existing UV and optical spectra, help determine the major radiative cooling channels for the chromosphere. This observation was to complement that previously planned for the mildly metal deficient giant alpha Boo (K2 III). However, a Boo has yet to be observed with FUSE.
Rotation Periods and Photometric Amplitudes for Cool Stars with TESS
NASA Astrophysics Data System (ADS)
Andrews, Hannah; Dominguez, Zechariah; Johnson, Sara; Buzasi, Derek L.
2018-06-01
The original Kepler mission observed 200000 stars in the same field nearly continuously for over four years, generating an unparalleled set of stellar rotation curves and new insights into the correlation between rotation periods and photometric variability on the lower main sequence. The continuation of Kepler in the guise of K2 has allowed us to examine a stellar sample comparable in size to that observed with Kepler, but drawn from new stellar populations. However, K2 observed each field for at most three months, limiting the inferences that can be drawn, particularly for older, slower-rotating stars. The upcoming TESS spacecraft will provide light curves for perhaps two orders of magnitude more stars, but with time windows as short as 27 days. In this work, we resample Kepler light curves using the TESS observing window, and study what can be learned from high-precision light curves of such short lengths, and how to compare those results to what we have learned from Kepler.
Chromospheric Activity in Population II Giants
NASA Technical Reports Server (NTRS)
Harper, Graham M.
2004-01-01
One of the mysteries of Population II giants is that they still show chromospheric emission despite their great age. The global dynamo which was active during their main-sequence lifetimes is expected to become extremely weak through magnetic rotational braking. The nature of the observed emission is not understood; although acoustic shock waves might provide the heating, acoustic waves are not predicted to drive the observed mass loss - which in turn requires the dissipation of magneto-hydrodynamic waves. This program was designed to search for the faint stellar H Ly beta emission wings and the fluorescent Fe II and H2 emission from one of the brightest, metal poor, Population II stars. These FUSE diagnostics, when combined with existing UV and optical spectra, help determine the major radiative cooling channels for the chromosphere. This observation was to complement that previously planned for the mildly metal deficient giant alpha Boo (K2 III). However, alpha Boo has yet to be observed with FUSE.
V380 Dra: New short-period totally eclipsing active binary
NASA Astrophysics Data System (ADS)
Özdarcan, O.
2014-02-01
In this study, first complete and standard BVR light curves and photometric analysis of the eclipsing binary system V380 Dra are presented. Photometric analysis result indicates that the system has components which are cool main sequence stars. In light and color curves, remarkable asymmetry is observed, especially after secondary minimum, which is believed to be a result of chromospheric activity in one or both components. O-C diagram of available small number of eclipse times, together with new eclipse timings in this work, exhibits no significant variation. Preliminary light curve solution shows that the secondary minimum is total eclipse. By using the advantage of total eclipse and mass-luminosity relation, it is found that the system has a possible mass ratio of q = 0.81. First estimation of masses and radii of primary and secondary components are M1 = 0.77 M⊙,M2 = 0.62 M⊙ and R1 = 0.93 R⊙,R2 = 0.77 R⊙, respectively.
Examining Cloud, Metallicity, and Gravity signatures in Brown Dwarfs
NASA Astrophysics Data System (ADS)
Gonzales, Eileen; Faherty, Jacqueline K.; Gagné, Jonathan; Artigau, Étienne; BDNYC
2018-01-01
The nearby solar neighborhood is littered with low mass, low temperature objects called brown dwarfs. This population of ultracool objects do not have enough mass to sustain stable hydrogen burning so they never enter the main sequence and simply cool through time. Brown dwarfs span effective temperatures in the range 250 to 3000K. They also have age dependent observable properties. Young brown dwarfs appear to have redder near infrared colors than field age sources, while old objects tend to have bluer colors. Over the past several years, the research group entitled “Brown Dwarfs in New York City” (BDNYC) has been collecting optical, near and mid-infrared spectra, as well as photometry for sources that have well defined distances. In this poster, I will compare the distance calibrated spectral energy distributions of a sample of old, young, and field age brown dwarfs of the same effective temperature. In so doing, I will discern observables linked to gravity, atmosphere, metallicity and age effects.
HUNTING THE COOLEST DWARFS: METHODS AND EARLY RESULTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schneider, A.; Song, Inseok; Melis, Carl
2011-12-20
We present the methods and first results of a survey of nearby high proper motion main-sequence stars to probe for cool companions with the Gemini camera at Lick Observatory. This survey uses a sample of old (age > 2 Gyr) stars as targets to probe for companions down to temperatures of 500 K. Multi-epoch observations allow us to discriminate comoving companions from background objects. So far, our survey has successfully rediscovered the wide T8.5 companion to GJ 1263 and has discovered a companion to the nearby M0V star GJ 660.1. The companion to GJ 660.1 (GJ 660.1B) is {approx}4 magmore » fainter than its host star in the J-band and is located at a projected separation of {approx}120 AU. Known trigonometric parallax and Two Micron All Sky Survey magnitudes for the GJ 660.1 system indicate a spectral type for the companion of M9 {+-} 2.« less
PG1258+593 and its common proper motion magnetic white dwarf counterpart
NASA Astrophysics Data System (ADS)
Girven, J.; Gänsicke, B. T.; Külebi, B.; Steeghs, D.; Jordan, S.; Marsh, T. R.; Koester, D.
2010-05-01
We confirm SDSSJ130033.48+590407.0 as a common proper motion companion to the well-studied hydrogen-atmosphere (DA) white dwarf PG1258+593 (GD322). The system lies at a distance of 68 +/- 3pc, where the angular separation of 16.1 +/- 0.1arcsec corresponds to a minimum binary separation of 1091 +/- 7au. SDSSJ1300+5904 is a cool (Teff = 6300 +/- 300K) magnetic white dwarf (B ~= 6mG). PG1258+593 is a DA white dwarf with Teff = 14790 +/- 77K and logg = 7.87 +/- 0.02. Using the white dwarf mass-radius relation implies the masses of SDSSJ1300+5904 and PG1258+593 are 0.54 +/- 0.06 and 0.54 +/- 0.01Msolar, respectively, and therefore a cooling age difference of 1.67 +/- 0.05Gyr. Adopting main-sequence lifetimes from stellar models, we derive an upper limit of 2.2Msolar for the mass of the progenitor of PG1258+593. A plausible range of initial masses is 1.4-1.8 Msolar for PG1258+593 and 2-3 Msolar for SDSSJ1300+5904. Our analysis shows that white dwarf common proper motion binaries can potentially constrain the white dwarf initial mass-final mass relation and the formation mechanism for magnetic white dwarfs. The magnetic field of SDSSJ1300+5904 is consistent with an Ap progenitor star. A common envelope origin of the system cannot be excluded, but requires a triple system as progenitor.
Wang, Kehua; Liu, Yanrong; Tian, Jinli; Huang, Kunyong; Shi, Tianran; Dai, Xiaoxia; Zhang, Wanjun
2017-01-01
Perennial ryegrass (Lolium perenne) is one of the most widely used forage and turf grasses in the world due to its desirable agronomic qualities. However, as a cool-season perennial grass species, high temperature is a major factor limiting its performance in warmer and transition regions. In this study, a de novo transcriptome was generated using a cDNA library constructed from perennial ryegrass leaves subjected to short-term heat stress treatment. Then the expression profiling and identification of perennial ryegrass heat response genes by digital gene expression analyses was performed. The goal of this work was to produce expression profiles of high temperature stress responsive genes in perennial ryegrass leaves and further identify the potentially important candidate genes with altered levels of transcript, such as those genes involved in transcriptional regulation, antioxidant responses, plant hormones and signal transduction, and cellular metabolism. The de novo assembly of perennial ryegrass transcriptome in this study obtained more total and annotated unigenes compared to previously published ones. Many DEGs identified were genes that are known to respond to heat stress in plants, including HSFs, HSPs, and antioxidant related genes. In the meanwhile, we also identified four gene candidates mainly involved in C4 carbon fixation, and one TOR gene. Their exact roles in plant heat stress response need to dissect further. This study would be important by providing the gene resources for improving heat stress tolerance in both perennial ryegrass and other cool-season perennial grass plants. PMID:28680431
Can Oort clouds pollute their parent stars after they become white dwarfs?
NASA Astrophysics Data System (ADS)
Veras, D.; Shannon, A.; Gänsicke, B. T.
2017-09-01
Comets impact the Sun frequently. In fact, coronographs like those which are part of Solar and Heliospheric Observatory (SOHO)/Large Angle and Spectrometric Coronagraph Experiment (LASCO) reveal that a comet grazes the Sun every few days, with a total of about 2400 grazers from 1996 to 2008. This frequency underscores an outstanding question in the quest to understand planetary systems: what types of small bodies - pebbles, asteroids, comets or moons - are the primary polluter of white dwarfs? We determine how often remnant exo-Oort clouds, freshly excited from post-main-sequence stellar mass loss, dynamically inject comets inside the white dwarf's Roche radius. We improve upon previous studies by considering a representative range of single white dwarf masses (0.52-1.00 M⊙) and incorporating different cloud architectures, giant branch stellar mass loss, stellar flybys, Galactic tides and a realistic escape ellipsoid in self-consistent numerical simulations that integrate beyond 8 Gyr ages of white dwarf cooling. We find that ˜10^(-5) of the material in an exo-Oort cloud is typically amassed onto the white dwarf, and that hydrogen deposits accumulate even as the cloud dissipates. This accumulation may account for the relatively large amount of trace hydrogen, 10^(22) -10^(25) g, that is determined frequently among white dwarfs with cooling ages ≥1 Gyr. Our results also reaffirm the notion that exo-Oort cloud comets are not the primary agents of the metal budgets observed in polluted white dwarf atmospheres.
Plasma arc welding repair of space flight hardware
NASA Technical Reports Server (NTRS)
Hoffman, David S.
1993-01-01
Repair and refurbishment of flight and test hardware can extend the useful life of very expensive components. A technique to weld repair the main combustion chamber of space shuttle main engines has been developed. The technique uses the plasma arc welding process and active cooling to seal cracks and pinholes in the hot-gas wall of the main combustion chamber liner. The liner hot-gas wall is made of NARloyZ, a copper alloy previously thought to be unweldable using conventional arc welding processes. The process must provide extensive heat input to melt the high conductivity NARloyZ while protecting the delicate structure of the surrounding material. The higher energy density of the plasma arc process provides the necessary heat input while active water cooling protects the surrounding structure. The welding process is precisely controlled using a computerized robotic welding system.
NASA Astrophysics Data System (ADS)
Stan, S.; Chisamera, M.; Riposan, I.; Neacsu, L.; Cojocaru, A. M.; Stan, I.
2017-06-01
With the more widespread adoption of thermal analysis testing, thermal analysis data have become an indicator of cast iron quality. The cooling curve and its first derivative display patterns that can be used to predict the characteristics of a cast iron. An experimental device was developed with a technique to simultaneously evaluate cooling curves and expansion or contraction of cast metals during solidification. Its application is illustrated with results on shrinkage tendency of ductile iron treated with FeSiMgRECa master alloy and inoculated with FeSi based alloys, as affected by mould rigidity (green sand and resin sand moulds). Undercooling at the end of solidification relative to the metastable (carbidic) equilibrium temperature and the expansion within the solidification sequence appear to have a strong influence on the susceptibility to macro - and micro - shrinkage in ductile iron castings. Green sand moulds, as less rigid moulds, encourage the formation of contraction defects, not only because of high initial expansion values, but also because of a higher cooling rate during solidification, and consequently, increased undercooling below the metastable equilibrium temperature up to the end of solidification.
The control system of a 2kW@20K helium refrigerator
NASA Astrophysics Data System (ADS)
Pan, W.; Wu, J. H.; Li, Qing; Liu, L. Q.; Li, Qiang
2017-12-01
The automatic control of a helium refrigerator includes three aspects, that is, one-button start and stop control, safety protection control, and cooling capacity control. The 2kW@20K helium refrigerator’s control system uses the SIEMENS PLC S7-300 and its related programming and configuration software Step7 and the industrial monitoring software WinCC, to realize the dynamic control of its process, the real-time monitoring of its data, the safety interlock control, and the optimal control of its cooling capacity. At first, this paper describes the control architecture of the whole system in detail, including communication configuration and equipment introduction; and then introduces the sequence control strategy of the dynamic processes, including the start and stop control mode of the machine and the safety interlock control strategy of the machine; finally tells the precise control strategy of the machine’s cooling capacity. Eventually, the whole system achieves the target of one-button starting and stopping, automatic fault protection and stable running to the target cooling capacity, and help finished the cold helium pressurization test of aerospace products.
Development and Experimental Evaluation of Passive Fuel Cell Thermal Control
NASA Technical Reports Server (NTRS)
Colozza, Anthony J.; Jakupca, Ian J.; Castle, Charles H.; Burke, Kenneth A.
2014-01-01
To provide uniform cooling for a fuel cell stack, a cooling plate concept was evaluated. This concept utilized thin cooling plates to extract heat from the interior of a fuel cell stack and move this heat to a cooling manifold where it can be transferred to an external cooling fluid. The advantages of this cooling approach include a reduced number of ancillary components and the ability to directly utilize an external cooling fluid loop for cooling the fuel cell stack. A number of different types of cooling plates and manifolds were developed. The cooling plates consisted of two main types; a plate based on thermopyrolytic graphite (TPG) and a planar (or flat plate) heat pipe. The plates, along with solid metal control samples, were tested for both thermal and electrical conductivity. To transfer heat from the cooling plates to the cooling fluid, a number of manifold designs utilizing various materials were devised, constructed, and tested. A key aspect of the manifold was that it had to be electrically nonconductive so it would not short out the fuel cell stack during operation. Different manifold and cooling plate configurations were tested in a vacuum chamber to minimize convective heat losses. Cooling plates were placed in the grooves within the manifolds and heated with surface-mounted electric pad heaters. The plate temperature and its thermal distribution were recorded for all tested combinations of manifold cooling flow rates and heater power loads. This testing simulated the performance of the cooling plates and manifold within an operational fuel cell stack. Different types of control valves and control schemes were tested and evaluated based on their ability to maintain a constant temperature of the cooling plates. The control valves regulated the cooling fluid flow through the manifold, thereby controlling the heat flow to the cooling fluid. Through this work, a cooling plate and manifold system was developed that could maintain the cooling plates within a minimal temperature band with negligible thermal gradients over power profiles that would be experienced within an operating fuel cell stack.
Native fat globules of different sizes selected from raw milk: thermal and structural behavior.
Michalski, Marie-Caroline; Ollivon, Michel; Briard, Valérie; Leconte, Nadine; Lopez, Christelle
2004-12-01
The aim of this study was to characterize differences in the thermal and structural behavior between different sized native milk fat globules. A novel microfiltration process permits the selection of native small fat globules (SFG, 1-3 microm) and large fat globules (LFG, >5 microm) in raw milk, that were analyzed by X-ray diffraction (XRD) coupled to differential scanning calorimetry (DSC). There were no major differences in triglyceride crystalline structures between SFG and LFG, after eliminating thermal history and the influence of cooling rates. The three main 3L and 2L crystalline structures appearing under slow cooling existed regardless of globule size. The supercooling increased for the SFG, mainly due to heterogeneous nucleation in winter milk, and also to compositional variations in spring milk. Differences appeared regarding stabilized crystalline forms at 20 degrees C and subsequent cooling: the SFG contained less 2L triglyceride structures than the LFG. These results can be important in dairy manufactures using tempering periods.
Pingali, Sai Venkatesh; O'Neill, Hugh Michael; Nishiyama, Yoshiharu; ...
2014-01-09
Morphological changes to the different components of lignocellulosic biomass were observed as they occurred during steam pretreatment by placing a pressure reaction cell in a neutron beam and collecting time-resolved neutron scattering data. Changes to cellulose morphology occurred mainly in the heating phase, whereas changes in lignin morphology occurred mainly in the holding and cooling phases. During the heating stage, water is irreversibly expelled from cellulose microfibrils as the elementary fibrils coalesce. During the holding phase lignin aggregates begin to appear and they increase in size most noticeably during the cooling phase. This experiment demonstrates the unique information that inmore » situ small angle neutron scattering studies of pretreatment can provide. This approach is potentially useful in optimizing the heating, holding and cooling stages of pretreatments to allow the exact size and nature of lignin aggregates to be controlled in order to enhance enzyme accessibility to cellulose and therefore the efficiency of biomass conversion.« less
NASA Technical Reports Server (NTRS)
Aquila, Valentina; Swartz, W.; Colarco, P.; Pawson, S.; Polvani, L.; Stolarski, R.; Waugh, D.
2015-01-01
Observations show that the cooling of global stratospheric temperatures from 1979 to 2015 took place in two major steps coincident with the 1982 El Chichon and 1991 Mount Pinatubo eruptions. In order to attribute the features of the global stratospheric temperature time series to the main forcing agents, we performed a set of simulations with the NASA Goddard Earth Observing System Chemistry Climate Model. Our results show that the characteristic step-like behavior is to be attributed to the effects of the solar cycle, except for the post-1995 flattening of the lower stratospheric temperatures, where the decrease in ozone depleting substances due to the Montreal Protocol slowed ozone depletion and therefore also the cooling of the stratosphere. Volcanic eruptions also caused a significant warming of the stratosphere after 1995. The observed general cooling is mainly caused by increasing ozone depleting substances in the lower stratosphere, and greenhouse gases in the middle and upper stratosphere.
Family ties of WR to LBV nebulae yielding clues for stellar evolution
NASA Astrophysics Data System (ADS)
Weis, K.
Luminous Blue Variables (LBVs) are stars is a transitional phase massive stars may enter while evolving from main-sequence to Wolf-Rayet stars. The to LBVs intrinsic photometric variability is based on the modulation of the stellar spectrum. Within a few years the spectrum shifts from OB to AF type and back. During their cool phase LBVs are close to the Humphreys-Davidson (equivalent to Eddington/Omega-Gamma) limit. LBVs have a rather high mass loss rate, with stellar winds that are fast in the hot and slower in the cool phase of an LBV. These alternating wind velocities lead to the formation of LBV nebulae by wind-wind interactions. A nebula can also be formed in a spontaneous giant eruption in which larger amounts of mass are ejected. LBV nebulae are generally small (< 5 pc) mainly gaseous circumstellar nebulae, with a rather large fraction of LBV nebulae being bipolar. After the LBV phase the star will turn into a Wolf-Rayet star, but note that not all WR stars need to have passed the LBV phase. Some follow from the RSG and the most massive directly from the MS phase. In general WRs have a large mass loss and really fast stellar winds. The WR wind may interact with winds of earlier phases (MS, RSG) to form WR nebulae. As for WR with LBV progenitors the scenario might be different, here no older wind is present but an LBV nebula! The nature of WR nebulae are therefore manifold and in particular the connection (or family ties) of WR to LBV nebulae is important to understand the transition between these two phases, the evolution of massive stars, their winds, wind-wind and wind-nebula interactions. Looking at the similarities and differences of LBV and WR nebula, figuring what is a genuine LBV and WR nebula are the basic question addressed in the analysis presented here.
Code of Federal Regulations, 2010 CFR
2010-07-01
... section as follows: Anode bake cycle means the period during which the regularly repeated sequence of loading, preheating, firing, cooling, and removing anodes from all sections within an anode bake furnace occurs one time. Anode bake furnace means an oven in which the formed green anodes are baked for use in a...
Code of Federal Regulations, 2013 CFR
2013-07-01
... section as follows: Anode bake cycle means the period during which the regularly repeated sequence of loading, preheating, firing, cooling, and removing anodes from all sections within an anode bake furnace occurs one time. Anode bake furnace means an oven in which the formed green anodes are baked for use in a...
Code of Federal Regulations, 2014 CFR
2014-07-01
... section as follows: Anode bake cycle means the period during which the regularly repeated sequence of loading, preheating, firing, cooling, and removing anodes from all sections within an anode bake furnace occurs one time. Anode bake furnace means an oven in which the formed green anodes are baked for use in a...
Code of Federal Regulations, 2011 CFR
2011-07-01
... section as follows: Anode bake cycle means the period during which the regularly repeated sequence of loading, preheating, firing, cooling, and removing anodes from all sections within an anode bake furnace occurs one time. Anode bake furnace means an oven in which the formed green anodes are baked for use in a...
Code of Federal Regulations, 2012 CFR
2012-07-01
... section as follows: Anode bake cycle means the period during which the regularly repeated sequence of loading, preheating, firing, cooling, and removing anodes from all sections within an anode bake furnace occurs one time. Anode bake furnace means an oven in which the formed green anodes are baked for use in a...
Two-phase flow in the cooling circuit of a cryogenic rocket engine
NASA Astrophysics Data System (ADS)
Preclik, D.
1992-07-01
Transient two-phase flow was investigated for the hydrogen cooling circuit of the HM7 rocket engine. The nuclear reactor code ATHLET/THESEUS was adapted to cryogenics and applied to both principal and prototype experiments for validation and simulation purposes. The cooling circuit two-phase flow simulation focused on the hydrogen prechilling and pump transient phase prior to ignition. Both a single- and a multichannel model were designed and employed for a valve leakage flow, a nominal prechilling flow, and a prechilling with a subsequent pump-transient flow. The latter case was performed in order to evaluate the difference between a nominal and a delayed turbo-pump start-up. It was found that an extension of the nominal prechilling sequence in the order of 1 second is sufficient to finally provide for liquid injection conditions of hydrogen which, as commonly known, is undesirable for smooth ignition and engine starting transients.
High energy bursts from a solid state laser operated in the heat capacity limited regime
Albrecht, G.; George, E.V.; Krupke, W.F.; Sooy, W.; Sutton, S.B.
1996-06-11
High energy bursts are produced from a solid state laser operated in a heat capacity limited regime. Instead of cooling the laser, the active medium is thermally well isolated. As a result, the active medium will heat up until it reaches some maximum acceptable temperature. The waste heat is stored in the active medium itself. Therefore, the amount of energy the laser can put out during operation is proportional to its mass, the heat capacity of the active medium, and the temperature difference over which it is being operated. The high energy burst capacity of a heat capacity operated solid state laser, together with the absence of a heavy, power consuming steady state cooling system for the active medium, will make a variety of applications possible. Alternately, cooling takes place during a separate sequence when the laser is not operating. Industrial applications include new material working processes. 5 figs.
High energy bursts from a solid state laser operated in the heat capacity limited regime
Albrecht, Georg; George, E. Victor; Krupke, William F.; Sooy, Walter; Sutton, Steven B.
1996-01-01
High energy bursts are produced from a solid state laser operated in a heat capacity limited regime. Instead of cooling the laser, the active medium is thermally well isolated. As a result, the active medium will heat up until it reaches some maximum acceptable temperature. The waste heat is stored in the active medium itself. Therefore, the amount of energy the laser can put out during operation is proportional to its mass, the heat capacity of the active medium, and the temperature difference over which it is being operated. The high energy burst capacity of a heat capacity operated solid state laser, together with the absence of a heavy, power consuming steady state cooling system for the active medium, will make a variety of applications possible. Alternately, cooling takes place during a separate sequence when the laser is not operating. Industrial applications include new material working processes.
NASA Astrophysics Data System (ADS)
Marziani, Paola; Sulentic, J. W.; Dultzin, D.; Negrete, A.; del Olmo, A.; Martínez-Carballo, M. A.; Stirpe, G. M.; D'Onofrio, M.; Perea, J.
2016-10-01
The 4D eigenvector 1 parameter space defined by Sulentic et al. may be seen as a surrogate H-R diagram for quasars. As in the stellar H-R diagram, a source sequence can be easily identified. In the case of quasars, the main sequence appears to be mainly driven by Eddington ratio. A transition Eddington ratio may in part explain the striking observational differences between quasars at opposite ends of the main sequence. The eigenvector-1 approach opens the door towards properly contextualized models of quasar physics, geometry and kinematics. We review some of the progress that has been made over the past 15 years, and point out still unsolved issues.
How the Plant Temperature Links to the Air Temperature in the Desert Plant Artemisia ordosica.
Yu, Ming-Han; Ding, Guo-Dong; Gao, Guang-Lei; Sun, Bao-Ping; Zhao, Yuan-Yuan; Wan, Li; Wang, De-Ying; Gui, Zi-Yang
2015-01-01
Plant temperature (Tp) is an important indicator of plant health. To determine the dynamics of plant temperature and self-cooling ability of the plant, we measured Tp in Artemisia ordosica in July, in the Mu Us Desert of Northwest China. Related factors were also monitored to investigate their effects on Tp, including environmental factors, such as air temperature (Ta), relative humidity, wind speed; and physiological factors, such as leaf water potential, sap flow, and water content. The results indicate that: 1) Tp generally changes in conjunction with Ta mainly, and varies with height and among the plant organs. Tp in the young branches is most constant, while it is the most sensitive in the leaves. 2) Correlations between Tp and environmental factors show that Tp is affected mainly by Ta. 3) The self-cooling ability of the plant was effective by midday, with Tp being lower than Ta. 4) Increasing sap flow and leaf water potential showed that transpiration formed part of the mechanism that supported self-cooling. Increased in water conductance and specific heat at midday may be additional factors that contribute to plant cooling ability. Therefore, our results confirmed plant self-cooling ability. The response to high temperatures is regulated by both transpiration speed and an increase in stem water conductance. This study provides quantitative data for plant management in terms of temperature control. Moreover, our findings will assist species selection with taking plant temperature as an index.
Dynamic modeling of temperature change in outdoor operated tubular photobioreactors.
Androga, Dominic Deo; Uyar, Basar; Koku, Harun; Eroglu, Inci
2017-07-01
In this study, a one-dimensional transient model was developed to analyze the temperature variation of tubular photobioreactors operated outdoors and the validity of the model was tested by comparing the predictions of the model with the experimental data. The model included the effects of convection and radiative heat exchange on the reactor temperature throughout the day. The temperatures in the reactors increased with increasing solar radiation and air temperatures, and the predicted reactor temperatures corresponded well to the measured experimental values. The heat transferred to the reactor was mainly through radiation: the radiative heat absorbed by the reactor medium, ground radiation, air radiation, and solar (direct and diffuse) radiation, while heat loss was mainly through the heat transfer to the cooling water and forced convection. The amount of heat transferred by reflected radiation and metabolic activities of the bacteria and pump work was negligible. Counter-current cooling was more effective in controlling reactor temperature than co-current cooling. The model developed identifies major heat transfer mechanisms in outdoor operated tubular photobioreactors, and accurately predicts temperature changes in these systems. This is useful in determining cooling duty under transient conditions and scaling up photobioreactors. The photobioreactor design and the thermal modeling were carried out and experimental results obtained for the case study of photofermentative hydrogen production by Rhodobacter capsulatus, but the approach is applicable to photobiological systems that are to be operated under outdoor conditions with significant cooling demands.
Glossary of terms and table of conversion factors used in design of chemical propulsion systems
NASA Technical Reports Server (NTRS)
Keller, R. B., Jr. (Compiler)
1979-01-01
The glossary presented is based entirely on terms used in the monographs on Chemical Propulsion. Significant terms relating to material properties and to material fabrication are presented. The terms are arranged in alphabetical order, with multiple word terms appearing in the normal sequence of usage; for example, ablative cooling appears as such, not as cooling, ablative, and lip seal appears as such, not as seal, lip. Conversion Factors for converting U.S. customary units to the International System of Units are presented in alphabetical order of the physical quantity (e.g., density, heat flux, specific impulse) involved.
Shaft seals with an easily removable cylinder holder for low-pressure steam turbines
NASA Astrophysics Data System (ADS)
Zakharov, A. E.; Rodionov, D. A.; Pimenov, E. V.; Sobolev, A. S.
2016-01-01
The article is devoted to the problems that occur at the operation of LPC shaft seals (SS) of turbines, particularly, their bearings. The problems arising from the deterioration of oil-protecting rings of SS and bearings and also the consequences in which they can result are considered. The existing SS housing construction types are considered. Their operational features are specified. A new SS construction type with an easily removable holder is presented. The construction of its main elements is described. The sequence of operations of the repair personnel at the restoration of the new SS type spacings is proposed. The comparative analysis of the new and the existing SS construction types is carried out. The assessment results of the efficiency, the operational convenience, and the economic effect after the installation of the new type seals are given. The conclusions about the offered construction prospects are made by results of the comparative analysis and the carried-out assessment. The main advantage of this design is the possibility of spacings restoration both in SS and in oil-protecting rings during a short-term stop of a turbine, even without its cooling. This construction was successfully tested on the working K-300-23.5 LMP turbine. However, its adaptation for other turbines is quite possible.
Performance analysis for minimally nonlinear irreversible refrigerators at finite cooling power
NASA Astrophysics Data System (ADS)
Long, Rui; Liu, Zhichun; Liu, Wei
2018-04-01
The coefficient of performance (COP) for general refrigerators at finite cooling power have been systematically researched through the minimally nonlinear irreversible model, and its lower and upper bounds in different operating regions have been proposed. Under the tight coupling conditions, we have calculated the universal COP bounds under the χ figure of merit in different operating regions. When the refrigerator operates in the region with lower external flux, we obtained the general bounds (0 < ε <(√{ 9 + 8εC } - 3) / 2) under the χ figure of merit. We have also calculated the universal bounds for maximum gain in COP under different operating regions to give a further insight into the COP gain with the cooling power away from the maximum one. When the refrigerator operates in the region located between maximum cooling power and maximum COP with lower external flux, the upper bound for COP and the lower bound for relative gain in COP present large values, compared to a relative small loss from the maximum cooling power. If the cooling power is the main objective, it is desirable to operate the refrigerator at a slightly lower cooling power than at the maximum one, where a small loss in the cooling power induces a much larger COP enhancement.
Electron cooling of a bunched ion beam in a storage ring
NASA Astrophysics Data System (ADS)
Zhao, He; Mao, Lijun; Yang, Jiancheng; Xia, Jiawen; Yang, Xiaodong; Li, Jie; Tang, Meitang; Shen, Guodong; Ma, Xiaoming; Wu, Bo; Wang, Geng; Ruan, Shuang; Wang, Kedong; Dong, Ziqiang
2018-02-01
A combination of electron cooling and rf system is an effective method to compress the beam bunch length in storage rings. A simulation code based on multiparticle tracking was developed to calculate the bunched ion beam cooling process, in which the electron cooling, intrabeam scattering (IBS), ion beam space-charge field, transverse and synchrotron motion are considered. Meanwhile, bunched ion beam cooling experiments have been carried out in the main cooling storage ring (CSRm) of the Heavy Ion Research Facility in Lanzhou, to investigate the minimum bunch length obtained by the cooling method, and study the dependence of the minimum bunch length on beam and machine parameters. The experiments show comparable results to those from simulation. Based on these simulations and experiments, we established an analytical model to describe the limitation of the bunch length of the cooled ion beam. It is observed that the IBS effect is dominant for low intensity beams, and the space-charge effect is much more important for high intensity beams. Moreover, the particles will not be bunched for much higher intensity beam. The experimental results in CSRm show a good agreement with the analytical model in the IBS dominated regime. The simulation work offers us comparable results to those from the analytical model both in IBS dominated and space-charge dominated regimes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, C.F.M.; Anderson, T.W.
A cool period from about 11000 to 10500 BP (11 to 10.5 ka) is recognized in pollen records from the southern Great Lakes area by the return of Picea and Abies dominance and by the persistence of herbs. The area of cooling appears centred on the Upper Great Lakes. A high-resolution record (ca. 9 mm/y) from a borehole in eastern Lake Erie reveals, in the same time interval, this pollen anomaly, isotope evidence of melt-water presence (a-3 per mil shift in {delta} {sup 18}O and a + 1.1 per mil shift in {delta}{sup 13}C), increased sand, and reduced detrital calcitemore » content, all suggesting concurrent cooling of Lake Erie. The onset of cooling is mainly attributed to the effect of enhanced meltwater inflow on the relatively large upstream Main Lake Agassiz. Termination of the cooling coincides with drainage of Lake Algonquin, and is attributed to loss of its cooling effectiveness associated with a substantial reduction in its surface area. It is hypothesized that that the cold extra in-flow effectively prolonged the seasonal presence of lake ice and the period of spring overturn in Lake Algonquin. The deep mixing would have greatly increased the thermal conductive capacity of this extensive lake, causing suppression of summer surface lakewater temperatures and reduction of onshore growing-degree days. Alternatively, a rapid flow of meltwater, buoyed on sediment-charged (denser) lakewater, may have kept the lake surface cold in summer. Other factors such as wind-shifted pollen deposition and possible effects from the Younger Dryas North Atlantic cooling could have contributed to the Great Lakes climatic reversal, but further studies are needed to resolve their relative significance. 51 refs., 5 figs.« less
Early Wuchiapingian cooling linked to Emeishan basaltic weathering?
NASA Astrophysics Data System (ADS)
Yang, Jianghai; Cawood, Peter A.; Du, Yuansheng; Condon, Daniel J.; Yan, Jiaxin; Liu, Jianzhong; Huang, Yan; Yuan, Dongxun
2018-06-01
The last glaciation during the late Paleozoic ice age commenced at around the Guadalupian-Lopingian (G-L) boundary and is synchronous with the emplacement of the Emeishan large igneous province. Using CA-TIMS zircon U-Pb dating, we obtained an age of 259.51 ± 0.21 Ma for the uppermost tuff from the Puan volcanic sequence in the eastern Emeishan large igneous province, constraining the timing of Emeishan volcanism and providing another candidate age for the G-L boundary. In addition, we determined an age of 259.69 ± 0.72 Ma for a basal claystone in the immediately overlying Longtan Formation from a drill core section in southwest South China. These ages, along with source weathering trends of mudstones from the lower Longtan Formation, and compiled paleotemperature records, indicate an earliest Wuchiapingian cooling coinciding with the onset of the last Permian glaciation. This global cooling is associated with positive shifts in both organic and carbonate carbon isotopic records and likely a decrease in atmospheric pCO2. A hypothesised causal linkage is proposed in which the rapid post-eruptive basaltic weathering of the Emeishan province in an equatorial humid belt may accelerate the atmospheric CO2 consumption and lead to climate cooling. Our work supports the long-term climate cooling effects of large igneous provinces.
Thermochronological Evidence for Cenozoic Segmentation of Transantarctic Mountains
NASA Astrophysics Data System (ADS)
Zattin, M.; Pace, D.; Andreucci, B.; Rossetti, F.; Talarico, F.
2013-12-01
The Transantarctic Mountains (TAM) represent the boundary between the cratonic East Antarctica and the West Antarctica and are thus related to formation of the Western Antarctic Rift system (WARS). However, temporal relationships between timing of TAM uplift and evolution of the WARS are not clear. The large amount of existing thermochronological data indicate that exhumation of the TAM occurred at different times and extents, with main cooling events in the Early Cretaceous, Late Cretaceous, and early Cenozoic. Uplift of the different segments of the TAM was not recorded according to regular trends along the mountain chain, but instead appears diachronous and without a recognizable spatial pattern. Here we present apatite fission-track (AFT) data from 20 samples, collected from metamorphic and intrusive rocks from the region comprised between the Blue Glacier and the Byrd Glacier. AFT data show a large variety of ages, ranging from 28.0 to 88.8 Ma and without a clear correlation between age and elevation. As a whole, spatial variations suggest a decrease of ages from S to the region of the Koettlitz Glacier, where ages suddenly raise up to Cretaceous values. A marked increase of ages has been detected also south of Darwin Glacier, that is in correspondence of the Britannia Range. Thermal modelling shows that cooling paths are usually composite, with a main cooling event followed by slower cooling to present day temperatures. Time of main cooling event is late Cretaceous for samples from the Britannia Range whereas it is Eocene-Oligocene for samples from Koettlitz and Mulock areas. In any case, cooling rates are always quite low also during periods of enhanced uplift, with values not exceeding 5°C/Ma. These data support the idea of tectonic block segmentation of the TAM during the last phases of exhumation. Most of vertical displacements occurred during the Oligocene across transverse fault zones such as the Discovery Accommodation Zone to the north and the Britannia Range to the south. The region comprised between these major tectonic structures represented probably a main source for the sediments that filled the Victoria Land basin during the Neogene. In fact bedrock AFT ages match well with detrital grain age distributions detected on sedimentary successions drilled by ANDRILL and CRP projects. Modelling of detrital AFT and apatite U-Th/He ages reveal that most of the source region was exhumed of about 5 km during Cenozoic. This value largely exceeds the estimated ice-related erosion which has been supposed to locally reach about 3 km along overdeepened pre-existing river valleys and in localized areas below sea level.
Application of cylindrical, triangular and hemispherical dimples in the film cooling technology
NASA Astrophysics Data System (ADS)
Khalatov, A. A.; Panchenko, N. A.; Severin, S. D.
2017-11-01
The results of film cooling numerical simulation over a flat plate with coolant supply through a single span-wise array of inclined (α = 30°) holes arranged inside cylindrical, triangular, and hemispherical dimples are represented in the paper. Such configurations are of a great practical interest for application in advanced blade cooling systems of high-performance gas turbines. The schemes with coolant supply into triangular and hemispherical dimples were first proposed and patented by the IET of the NAS of Ukraine. For numerical simulation the ANSYS CFX 14 commercial code was used. Numerical simulation were carried out in a wide range of the blowing ratio parameter varied from 0.5 to 2.0. For low blowing ratio parameter (m = 0.5) the laterally averaged film cooling efficiency is actually the same for all investigated schemes over the main film cooling area. In this area, the most simple in terms of the film cooling production technology configuration can be used. At the medium and high blowing ratios (m = 1.0 or higher) all investigated film cooling schemes allow to increase the laterally averaged film cooling efficiency in comparison with the traditional cooling scheme with single row of incline holes. In this case the configuration with coolant supply into triangular dimples of the «crater» type demonstrates the best film cooling efficiency due to significant reduction in the intensity and scale of the “kidney” vortex beyond configuration, as well as due to decrease in the coolant blowing non-uniformity factor.
ERIC Educational Resources Information Center
Kuhnle, Carl J., Jr.
The program proposal is designed to address the increasing demand for trained personnel to support the installation and maintenance of solar energy systems at residential and commercial sites. The three main objectives of the proposed program are: (1) to develop a flexible curricula to train a solar heating and cooling workforce; (2) to identify…
Effect of Cooling Rate on Microstructure of Two Kinds of High Nb Containing Tial Alloys
NASA Astrophysics Data System (ADS)
Chai, L. H.; Feng, Z. Y.; Xiang, Z. L.; Cui, Y. S.; Zhou, F.; Chen, Z. Y.
2017-09-01
In this paper, high Nb-TiAl alloys with Cr and W additions were prepared by Vacuum induction melting method, and then were heat treated under three different cooling rates of slow cooling, furnace cooling and air cooling. The phase composition of the alloy was analyzed by X ray diffraction, and the microstructure of the alloy was observed by optical microscope (OM), scanning electron microscope (SEM) and energy dispersive analyzer. The results show that the microstructure of Ti45Al8Nb0.2Cr and Ti45Al8Nb0.2W are fully lamellar structure with the main phase composition of α+γ after 3 different heat treatment conditions. The grain size of the two alloys decreases with decreasing of cooling rate, and the grain size of the alloyed with Cr alloy is smaller than that of the alloyed with W alloy. Most of the original massive β phase at grain boundaries and lamellar interfaces dissolved after heat treatment, and the transformation of β phase is easier for Ti45Al8Nb0.2Cr.
Properties of quasi-periodic oscillations in accreting magnetic white dwarfs
NASA Technical Reports Server (NTRS)
Wu, Kinwah; Chanmugam, G.; Shaviv, G.
1992-01-01
Previous studies of time-dependent accretion onto magnetic white dwarfs, in which the cooling was assumed to be due to bremsstrahlung emission, have shown that the accretion shock undergoes oscillations. However, when cyclotron cooling is also included, the oscillations are damped for sufficiently strong magnetic fields. Here we demonstrate that the oscillations can be sustained by accretion-fluctuation-induced excitations. The frequency of the QPOs are shown to increase quadratically with the magnetic field strength. We interpret the oscillations as a two-phase process in which bremsstrahlung cooling dominates in one half-cycle and cyclotron cooling in the other. Such a process may have very different consequences compared to a single-phase process where the functional form of the cooling is essentially the same throughout the cycle. If in the two-phase process damping occurs mainly in the cyclotron cooling half-cycle, there will be a universal effective damping factor which tends to suppress all oscillation modes indiscriminately. The oscillations of the accretion shock also could be a limit cycle process in which the system vacillates between two branches.
Superhumps and Repetitive Rebrightenings of the WZ Sge-Type Dwarf Nova, EG Cancri
NASA Astrophysics Data System (ADS)
Kato, Taichi; Nogami, Daisaku; Matsumoto, Katsura; Baba, Hajime
2004-03-01
We report on time-resolved photometric observations of the WZ Sge-type dwarf nova, EG Cnc (Huruhata's variable), during its superoutburst in 1996-1997. EG Cnc, after the main superoutburst accompanied by the development of superhumps typical of a WZ Sge-type dwarf nova, exhibited a series of six major rebrightenings. During these rebrightenings and the following long fading tail, EG Cnc persistently showed superhumps having a period equal to the superhump period observed during the main superoutburst. The persistent superhumps had a constant superhump flux with respect to the rebrightening phase. These findings suggest that the superhumps observed during the rebrightening stage and the fading tail are a ``remnant'' of the usual superhumps, and are not newly triggered by rebrightenings. By a comparison with the 1977 outburst of this object and outbursts of other WZ Sge-type dwarf novae, we propose an activity sequence of WZ Sge-type superoutbursts, in which the current outburst of EG Cnc is placed between a single-rebrightening event and distinct outbursts separated by a dip. The post-superoutburst behavior of WZ Sge-type dwarf novae can be understood in the presence of a considerable amount of remnant matter behind the cooling front in the outer accretion disk, even after the main superoutburst. We consider that a premature quenching of the hot state due to the weak tidal effect under the extreme mass ratio of the WZ Sge-type binary is responsible for the origin of the remnant mass.
Main processes of the Atlantic cold tongue interannual variability
NASA Astrophysics Data System (ADS)
Planton, Yann; Voldoire, Aurore; Giordani, Hervé; Caniaux, Guy
2018-03-01
The interannual variability of the Atlantic cold tongue (ACT) is studied by means of a mixed-layer heat budget analysis. A method to classify extreme cold and warm ACT events is proposed and applied to ten various analysis and reanalysis products. This classification allows 5 cold and 5 warm ACT events to be selected over the period 1982-2007. Cold (warm) ACT events are defined by the presence of negative (positive) sea surface temperature (SST) anomalies at the center of the equatorial Atlantic in late boreal spring, preceded by negative (positive) zonal wind stress anomalies in the western equatorial Atlantic. An ocean general circulation model capable of reconstructing the interannual variability of the ACT correctly is used to demonstrate that cold ACT events develop rapidly from May to June mainly due to intense cooling by vertical mixing and horizontal advection. The simulated cooling at the center of the basin is the result of the combined effects of non-local and local processes. The non-local process is an upwelling associated with an eastward-propagating Kelvin wave, which makes the mixed-layer more shallow and preconditions the upper layers to be cooled by an intense heat loss at the base of the mixed-layer, which is amplified by a stronger local injection of energy from the atmosphere. The early cooling by vertical mixing in March is also shown to be a good predictor of June cooling. In July, horizontal advection starts to warm the mixed-layer abnormally and damps SST anomalies. The advection anomalies, which result from changes in the horizontal temperature gradient, are associated in some cases with the propagation of Rossby waves along the equator. During warm ACT events, processes are reversed, generating positive SST anomalies: a downwelling Kelvin wave triggers stratification anomalies and mixed-layer depth anomalies, amplified by a weaker injection of energy from the atmosphere in May-June. In July, warm ACT events are abnormally cooled due to negative horizontal advection anomalies resulting from processes similar to those that occur during cold ACT events. This additional cooling process extends the period of cooling of the ACT, reducing SST anomalies.
Loss of control air at Browns Ferry Unit One: accident sequence analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrington, R.M.; Hodge, S.A.
1986-04-01
This study describes the predicted response of the Browns Ferry Nuclear Plant to a postulated complete failure of plant control air. The failure of plant control air cascades to include the loss of drywell control air at Units 1 and 2. Nevertheless, this is a benign accident unless compounded by simultaneous failures in the turbine-driven high pressure injection systems. Accident sequence calculations are presented for Loss of Control Air sequences with assumed failure upon demand of the Reactor Core Isolation Cooling (RCIC) and the High Pressure Coolant Injection (HPCI) at Unit 1. Sequences with and without operator action are considered.more » Results show that the operators can prevent core uncovery if they take action to utilize the Control Rod Drive Hydraulic System as a backup high pressure injection system.« less
On the Detection and Characterization of Polluted White Dwarfs
NASA Astrophysics Data System (ADS)
Steele, Amy; Debes, John H.; Deming, Drake
2017-06-01
There is evidence of circumstellar material around main sequence, giant, and white dwarf stars. What happens to this material after the main sequence? With this work, we focus on the characterization of the material around WD 1145+017. The goals are to monitor the white dwarf—which has a transiting, disintegrating planetesimal and determine the composition of the evaporated material for that same white dwarf by looking at high-resolution spectra. We also present preliminary results of follow-up photometric observations of known polluted WDs. If rocky bodies survive red giant branch evolution, then the material raining down on a WD atmosphere is a direct probe of main sequence cosmochemistry. If rocky bodies do not survive the evolution, then this informs the degree of post-main-sequence processing. These case studies will provide the community with further insight about debris disk modeling, the degree of post-main-sequence processing of circumstellar material, and the composition of a disintegrating planetesimal.
A catalog of aftershock sequences in Greece (1971 1997): Their spatial and temporal characteristics
NASA Astrophysics Data System (ADS)
Drakatos, George; Latoussakis, John
A complete catalog of aftershock sequences is provided for main earthquakes with ML 5.0, which occurred in the area of Greece and surrounding regions the last twenty-seven years. The Monthly Bulletins of the Institute of Geodynamics (National Observatory of Athens) have been used as data source. In order to get a homogeneous catalog, several selection criteria have been applied and hence a catalog of 44 aftershock sequences is compiled. The relations between the duration of the sequence, the number of aftershocks, the magnitude of the largest aftershock and its delay time from the main shock as well as the subsurface rupture length versus the magnitude of the main shock are calculated. The results show that linearity exists between the subsurface rupture length and the magnitude of the main shock independent of the slip type, as well as between the magnitude of the main shock (M) and its largest aftershock (Ma). The mean difference M-Ma is almost one unit. In the 40% of the analyzed sequences, the largest aftershock occurred within one day after the main shock.The fact that the aftershock sequences show the same behavior for earthquakes that occur in the same region supports the theory that the spatial and temporal characteristics are strongly related to the stress distribution of the fault area.
Weiss, Don; Boyd, Christopher; Rakeman, Jennifer L; Greene, Sharon K; Fitzhenry, Robert; McProud, Trevor; Musser, Kimberlee; Huang, Li; Kornblum, John; Nazarian, Elizabeth J; Fine, Annie D; Braunstein, Sarah L; Kass, Daniel; Landman, Keren; Lapierre, Pascal; Hughes, Scott; Tran, Anthony; Taylor, Jill; Baker, Deborah; Jones, Lucretia; Kornstein, Laura; Liu, Boning; Perez, Rodolfo; Lucero, David E; Peterson, Eric; Benowitz, Isaac; Lee, Kristen F; Ngai, Stephanie; Stripling, Mitch; Varma, Jay K
Infections caused by Legionella are the leading cause of waterborne disease outbreaks in the United States. We investigated a large outbreak of Legionnaires' disease in New York City in summer 2015 to characterize patients, risk factors for mortality, and environmental exposures. We defined cases as patients with pneumonia and laboratory evidence of Legionella infection from July 2 through August 3, 2015, and with a history of residing in or visiting 1 of several South Bronx neighborhoods of New York City. We describe the epidemiologic, environmental, and laboratory investigation that identified the source of the outbreak. We identified 138 patients with outbreak-related Legionnaires' disease, 16 of whom died. The median age of patients was 55. A total of 107 patients had a chronic health condition, including 43 with diabetes, 40 with alcoholism, and 24 with HIV infection. We tested 55 cooling towers for Legionella, and 2 had a strain indistinguishable by pulsed-field gel electrophoresis from 26 patient isolates. Whole-genome sequencing and epidemiologic evidence implicated 1 cooling tower as the source of the outbreak. A large outbreak of Legionnaires' disease caused by a cooling tower occurred in a medically vulnerable community. The outbreak prompted enactment of a new city law on the operation and maintenance of cooling towers. Ongoing surveillance and evaluation of cooling tower process controls will determine if the new law reduces the incidence of Legionnaires' disease in New York City.
A case of nosocomial Legionella pneumonia associated with a contaminated hospital cooling tower.
Osawa, Kayo; Shigemura, Katsumi; Abe, Yasuhisa; Jikimoto, Takumi; Yoshida, Hiroyuki; Fujisawa, Masato; Arakawa, Soichi
2014-01-01
We report the epidemiological investigation of a nosocomial pneumonia case due to Legionella pneumophila linked to a contaminated hospital cooling tower in an immune-compromised patient. A 73-year-old female patient was diagnosed with nosocomial Legionella pneumonia proven by a culture of L. pneumophila serogroup 1 from bronchoalveolar lavage fluid. Two strains isolated from the patient and two strains isolated from two cooling towers were found to be identical using repetitive-sequence-based-PCR with a 95% probability. This Legionella pneumonia case might be caused by aerosol from cooling towers on the roof of the hospital building which was contaminated by L. pneumophila. We increased up the temperature of hot water supply appropriately for prevention of Legionella breeding in an environment of patients' living. On the other hand, as the maintenance of cooling tower, we increased the frequency of Legionella culture tests from twice a year to three times a year. In addition, we introduced an automated disinfectants insertion machine and added one antiseptic reagent (BALSTER ST-40 N, Tohzai Chemical Industry Co., Ltd., Kawasaki, Japan) after this Legionella disease, and thereafter, we have no additional cases of Legionella disease or detection of Legionella spp. from the cooling tower or hot water supply. This case demonstrates the importance of detecting the infection source and carrying out environmental maintenance in cooperation with the infection control team. Copyright © 2013 Japanese Society of Chemotherapy and the Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Boyd, Christopher; Rakeman, Jennifer L.; Greene, Sharon K.; Fitzhenry, Robert; McProud, Trevor; Musser, Kimberlee; Huang, Li; Kornblum, John; Nazarian, Elizabeth J.; Fine, Annie D.; Braunstein, Sarah L.; Kass, Daniel; Landman, Keren; Lapierre, Pascal; Hughes, Scott; Tran, Anthony; Taylor, Jill; Baker, Deborah; Jones, Lucretia; Kornstein, Laura; Liu, Boning; Perez, Rodolfo; Lucero, David E.; Peterson, Eric; Benowitz, Isaac; Lee, Kristen F.; Ngai, Stephanie; Stripling, Mitch; Varma, Jay K.
2017-01-01
Objectives: Infections caused by Legionella are the leading cause of waterborne disease outbreaks in the United States. We investigated a large outbreak of Legionnaires’ disease in New York City in summer 2015 to characterize patients, risk factors for mortality, and environmental exposures. Methods: We defined cases as patients with pneumonia and laboratory evidence of Legionella infection from July 2 through August 3, 2015, and with a history of residing in or visiting 1 of several South Bronx neighborhoods of New York City. We describe the epidemiologic, environmental, and laboratory investigation that identified the source of the outbreak. Results: We identified 138 patients with outbreak-related Legionnaires’ disease, 16 of whom died. The median age of patients was 55. A total of 107 patients had a chronic health condition, including 43 with diabetes, 40 with alcoholism, and 24 with HIV infection. We tested 55 cooling towers for Legionella, and 2 had a strain indistinguishable by pulsed-field gel electrophoresis from 26 patient isolates. Whole-genome sequencing and epidemiologic evidence implicated 1 cooling tower as the source of the outbreak. Conclusions: A large outbreak of Legionnaires’ disease caused by a cooling tower occurred in a medically vulnerable community. The outbreak prompted enactment of a new city law on the operation and maintenance of cooling towers. Ongoing surveillance and evaluation of cooling tower process controls will determine if the new law reduces the incidence of Legionnaires’ disease in New York City. PMID:28141970
2017-01-12
J =0.13%, FFC Varies (b) J =0.13%, Main chamber Varies ( c ) J ...b) J =0.13%, Main Varies ( c ) J =1.23%, FFC Varies (d) J =1.18%, Main Varies (e) J =7.89%, FFC Varies (f) J =7.34%, Main Varies Figure 8. Power Spectral...Statement A: Approved for Public Release; Distribution Unlimited. PA Clearance #16569 (a) J =0.13%, FFC Varies (b) J =0.13%, Main Varies ( c ) J =2.79%,
NASA Astrophysics Data System (ADS)
Danise, Silvia; Holland, Steven
2017-04-01
Understanding how regional ecosystems respond to sea level and environmental perturbations is a main challenge in palaeoecology. Here we use quantitative abundance estimates, integrated within a sequence stratigraphic and environmental framework, to reconstruct benthic community changes through the 13 myr history of the Jurassic Sundance Seaway in the western United States. Faunal censuses of macroinvertebrates were obtained from marine rocks of the Gypsum Spring, Sundance and Twin Creek formations at 44 localities in Wyoming, Montana and South Dakota. Fossils were identified to species wherever possible. Ordination of samples shows a main turnover event at the Middle-Upper Jurassic transition, which coincided with the shift from carbonate to siliciclastic depositional systems in the Seaway. This shift was probably initiated by the northward migration of the North American Plate, which moved the study area from subtropical latitudes, fostering an arid climate, into progressively more humid conditions, and possibly also by global cooling at this time. Turnover was not uniform across the onshore-offshore gradient, but was higher in offshore environments, in both carbonate and siliciclastic settings. Both the Jaccard and the Bray-Curtis similarity measures indicate that taxonomic similarity decreases from onshore to offshore in successive third-order depositional sequences, although similarity values are low for both onshore and offshore environments The higher resilience of onshore communities to third-order sea-level fluctuations and to the change from a carbonate to a siliciclastic system was driven by a few abundant eurytopic species that persisted from the opening to the closing of the Seaway and that were not restricted to single depositional environments or sequences. Lower stability in offshore facies was instead controlled by the presence of more volatile stenotopic species. Such increased onshore stability in community composition contrasts with the well-documented onshore increase in taxonomic turnover rates, and indicates the need for ecological studies to complement taxonomic studies of macroevolutionary events. This study also shows how a stratigraphic palaeobiological approach is essential for understanding the link between environmental and faunal gradients, and for understanding the long-term changes in these gradients over time that produce the local stratigraphical pattern of changes in community composition.
Numerical study of a cryogen-free vuilleumier type pulse tube cryocooler operating below 10 K
NASA Astrophysics Data System (ADS)
Wang, Y. N.; Wang, X. T.; Dai, W.; Luo, E. C.
2017-12-01
This paper presents a numerical investigation on a Vuilleumier (VM) type pulse tube cooler. Different from previous systems that use liquid nitrogen, Stirling type pre-coolers are used to provide the cooling power for the thermal compressor, which leads to a convenient cryogen-free system and offers the flexibility of changing working temperature range of the thermal compressor to obtain an optimum efficiency. Firstly, main component dimensions were optimized with lowest no-load temperature as the target. Then the dependence of system performance on average pressure, frequency, displacer displacement amplitude and thermal compressor pre-cooling temperature were studied. Finally, the effect of pre-cooling temperature on overall cooling efficiency at 5 K was studied. A highest relative Carnot efficiency of 0.82 % was predicted with an average pressure of 2.5 MPa, a frequency of 3 Hz, a displacer displacement amplitude of 6.5 mm, ambient end temperature 300 K and pre-cooling temperature 65 K, respectively.
USDA-ARS?s Scientific Manuscript database
Predicted rising global temperatures due to climate change have generated a demand for crops that are resistant to yield and quality losses from heat stress. Broccoli (Brassica oleracea var. italica) is a cool weather crop with high temperatures during production decreasing both head quality and yie...
USDA-ARS?s Scientific Manuscript database
Broccoli is a cool weather vegetable crop with a vernalization requirement to initiate and maintain floral development. Breeding for heat tolerance in broccoli has the potential to both expand viable production areas and extend the growing season. A doubled haploid (DH) population of broccoli (Bras...
Legionella busanensis sp. nov., isolated from cooling tower water in Korea.
Park, Mi-Yeoun; Ko, Kwan Soo; Lee, Hae Kyung; Park, Man-Suk; Kook, Yoon-Hoh
2003-01-01
Three Legionella-like micro-organisms, isolated from cooling tower water of a building in Busan, Korea, were characterized by a variety of biochemical and molecular phylogenetic tests. Analyses of whole-cell fatty acids and results of biochemical tests revealed that these three isolates are distinct from previously described Legionella species. Furthermore, results of comparative analyses of 16S rDNA (1476-1488 bp), mip (408 bp) and rpoB (300 bp) sequences also confirmed that these strains represent a novel species within the genus Legionella. The 16S rDNA sequences of the three Korean isolates had similarities of less than 95.8% to other Legionella species. Phylogenetic trees formed by analysis of the 16S rRNA, rpoB and mip genes revealed that the isolates formed a distinct cluster within the genus Legionella. Based on the evaluated phenotypic and phylogenetic characteristics, it is proposed that these Korean isolates from water be classified as a novel species, Legionella busanensis sp. nov.; the type strain is strain K9951T (=KCTC 12084T =ATCC BAA-518T).
Furuhata, Katsunori; Ishizaki, Naoto; Edagawa, Akiko; Fukuyama, Masafumi
2013-01-01
Strain K-20(T), a Gram-negative, nonmotile, nonspore-forming and strictly aerobic coccobacillus, which produces a pale pink pigment (R2A agar medium, 30℃, seven days) was isolated from a sample of biofilm obtained from a cooling tower in Tokyo, Japan. A phylogenetic analysis of the 16S rRNA partial gene sequences (1,439 bp) showed that the strain (accession number: AB297501) was related to Roseomonas frigidaquae CW67(T) and Roseomonas stagni HS-69(T) with 97.4% and 96.9% sequence similarity, respectively. Strain K-20(T) formed a distinct cluster with Roseomonas frigidaquae CW67(T) in the phylogenetic tree at a high bootstrap value (93%); however, distance was recognized between the strains. In addition, the DNA-DNA hybridization level between strain K-20(T) and Roseomonas frigidaquae JCM 15073(T) was 33%. The taxonomic data indicate that K-20(T) (=JCM 14634(T) =KCTC 32152(T)) should be classified in the genus Roseomonas as the type strain of a novel species, Roseomonas tokyonensis sp. nov.
Columbia/Einstein observations of galactic X-ray sources
NASA Technical Reports Server (NTRS)
Long, K. S.
1979-01-01
The imaging observations of galactic clusters are presented. These fall into three categories: pre-main-sequence stars in the Orion nebulae, isolated-main-and-post main-sequence stars, and supernova remnants SNR. In addition to SNR, approximately 30 sources were detected.
Influence of coolant tube curvature on film cooling effectiveness as detected by infrared imagery
NASA Technical Reports Server (NTRS)
Papell, S. S.; Graham, R. W.; Cageao, R. P.
1979-01-01
Thermal film cooling footprints observed by infrared imagery from straight, curved, and looped coolant tube geometries are compared. It was hypothesized that the differences in secondary flow and in the turbulence structure of flow through these three tubes should influence the mixing properties between the coolant and the main stream. A flow visualization tunnel, an infrared camera and detector, and a Hilsch tube were employed to test the hypothesis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daling, P.M.; Marler, J.E.; Vo, T.V.
This study evaluates the values (benefits) and impacts (costs) associated with potential resolutions to Generic Issue 143, ``Availability of HVAC and Chilled Water Systems.`` The study identifies vulnerabilities related to failures of HVAC, chilled water, and room cooling systems; develops estimates of room heatup rates and safety-related equipment vulnerabilities following losses of HVAC/room cooler systems; develops estimates of the core damage frequencies and public risks associated with failures of these systems; develops three proposed resolution strategies to this generic issue; and performs a value/impact analysis of the proposed resolutions. Existing probabilistic risk assessments for four representative plants, including one plantmore » from each vendor, form the basis for the core damage frequency and public risk calculations. Both internal and external events were considered. It was concluded that all three proposed resolution strategies exceed the $1,000/person-rem cost-effectiveness ratio. Additional evaluations were performed to develop ``generic`` insights on potential design-related and configuration-related vulnerabilities and potential high-frequency ({approximately}1E-04/RY) accident sequences that involve failures of HVAC/room cooling functions. It was concluded that, although high-frequency accident sequences may exist at some plants, these high-frequency sequences are plant-specific in nature or have been resolved through hardware and/or operational changes. The plant-specific Individual Plant Examinations are an effective vehicle for identification and resolution of these plant-specific anomalies and hardware configurations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schultz, R.R.
1982-01-01
Operating plant transients are of great interest for many reasons, not the least of which is the potential for a mild transient to degenerate to a severe transient yielding core damage. Using the Browns Ferry (BF) Unit-1 plant as a basis of study, the station blackout sequence was investigated by the Severe Accident Sequence Analysis (SASA) Program in support of the Nuclear Regulatory Commission's Unresolved Safety Issue A-44: Station Blackout. A station blackout transient occurs when the plant's AC power from a comemrcial power grid is lost and cannot be restored by the diesel generators. Under normal operating conditions, fmore » a loss of offsite power (LOSP) occurs (i.e., a complete severance of the BF plants from the Tennessee Valley Authority (TVA) power grid), the eight diesel generators at the three BF units would quickly start and power the emergency AC buses. Of the eight diesel generators, only six are needed to safely shut down all three units. Examination of BF-specific data show that LOSP frequency is low at Unit 1. The station blackout frequency is even lower (5.7 x 10/sup -4/ events per year) and hinges on whether the diesel generators start. The frequency of diesel generator failure is dictated in large measure by the emergency equipment cooling water (EECW) system that cools the diesel generators.« less
Prof. Hayashi's work on the pre-main sequence evolution and brown dwarfs
NASA Astrophysics Data System (ADS)
Nakano, Takenori
2012-09-01
Prof. Hayashi's work on the evolution of stars in the pre-main sequence stage is reviewed. The historical background and the process of finding the Hayashi phase are mentioned. The work on the evolution of low-mass stars is also reviewed including the determination of the bottom of the main sequence and evolution of brown dwarfs, and comparison is made with the other works in the same period.
Renesting by American woodcocks (Scolopax minor) in Maine
McAuley, D.G.; Longcore, J.R.; Sepik, G.F.
1990-01-01
The American Woodcock (Scolopax minor) is one of the earliest ground-nesting birds in the northeastern United States. In Maine, nesting begins in early April when temperatures can drop below freezing and significant snowfall can accumulate. Nests are usually in open woods, where eggs are laid on the ground in a shallow depression (Pettingill 1936, Mendall and Aldous 1943, Sheldon 1967). Peak hatching occurs in early May (Dwyer et al. 1982), when temperatures are cool and precipitation is common. Woodcock chicks are dependent on the female for most of their food for at least seven days after hatching (Gregg 1984). During cool, wet weather, chicks require constant brooding by females; prolonged periods of inclement weather may lead to substantial mortality of chicks (Dwyer et al. 1988).
Cooling for SC devices of test cryomodule for ADS Injector II at IMP
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, L.; Wang, S. Y.; Sun, S.
2014-01-29
The superconducting half-wave resonance cavities connected in series with superconducting solenoids will be applied to the Injector II of the Accelerator Driven Sub-critical System (ADS) to be built at the Modern Physics Institute, China. A test system has been developed for the purpose of performance test of the HWR cavities as well as validating the relevant technique for cooling the cavity and the solenoids together. It mainly comprises a cryogenic valve box (TVB), a test cryomodule (TCM1) and transfer lines. The TCM1 includes one HWR cavity, two superconducting solenoids, one cold BPM and their cooling system. The design of themore » TCM1 cryostat was carried out by the Shanghai Institute of Applied Physics (SINAP), CAS. Both the cavity and the solenoids will work at 4.4 K by bath cooling. The fast cooling down for the cavity from around 100 K to 120 K is required to avoid degrading of the cavity performance. After cool down and before energization, the solenoids should be warmed up to above 10 K and re-cooled down for the purpose of degaussing. The TCM1 can not only be cooled by using the dewar-filling system, but also operated by the refrigerator system. For the purpose of reducing the heat loads to the cold mass at 4 K from room temperature, thermal radiation shields cooled by liquid nitrogen flowing in tubing were employed. This paper presents the design details of cooling circuits and thermal shields of the TCM1 as well as related calculations and analyses.« less
Cooling for SC devices of test cryomodule for ADS Injector II at IMP
NASA Astrophysics Data System (ADS)
Wang, L.; Wang, S. Y.; Sun, S.; Guo, X. L.; Wang, S. H.; Liu, Y. Y.
2014-01-01
The superconducting half-wave resonance cavities connected in series with superconducting solenoids will be applied to the Injector II of the Accelerator Driven Sub-critical System (ADS) to be built at the Modern Physics Institute, China. A test system has been developed for the purpose of performance test of the HWR cavities as well as validating the relevant technique for cooling the cavity and the solenoids together. It mainly comprises a cryogenic valve box (TVB), a test cryomodule (TCM1) and transfer lines. The TCM1 includes one HWR cavity, two superconducting solenoids, one cold BPM and their cooling system. The design of the TCM1 cryostat was carried out by the Shanghai Institute of Applied Physics (SINAP), CAS. Both the cavity and the solenoids will work at 4.4 K by bath cooling. The fast cooling down for the cavity from around 100 K to 120 K is required to avoid degrading of the cavity performance. After cool down and before energization, the solenoids should be warmed up to above 10 K and re-cooled down for the purpose of degaussing. The TCM1 can not only be cooled by using the dewar-filling system, but also operated by the refrigerator system. For the purpose of reducing the heat loads to the cold mass at 4 K from room temperature, thermal radiation shields cooled by liquid nitrogen flowing in tubing were employed. This paper presents the design details of cooling circuits and thermal shields of the TCM1 as well as related calculations and analyses.
NASA Astrophysics Data System (ADS)
Gómez, J. J.; Comas-Rengifo, M. J.; Goy, A.
2015-08-01
One of the main controversial items in palaeoclimatology is to elucidate if climate during the Jurassic was warmer than present day, with no ice caps, or if ice caps were present in some specific intervals. The Pliensbachian Cooling event (Lower Jurassic) has been pointed out as one of the main candidates to have developed ice caps on the poles. To constrain the timing of this cooling event, including the palaeoclimatic evolution before and after cooling, as well as the calculation of the seawater palaeotemperatures are of primary importance to find arguments on this subject. For this purpose, the Rodiles section of the Asturian Basin (Northern Spain), a well exposed succession of the uppermost Sinemurian, Pliensbachian and Lower Toarcian deposits, has been studied. A total of 562 beds were measured and sampled for ammonites, for biostratigraphical purposes and for belemnites, to determine the palaeoclimatic evolution through stable isotope studies. Comparison of the recorded uppermost Sinemurian, Pliensbachian and Lower Toarcian changes in seawater palaeotemperature with other European sections allows characterization of several climatic changes of probable global extent. A warming interval which partly coincides with a negative δ13Cbel excursion was recorded at the Upper Sinemurian. After a "normal" temperature interval, a new warming interval that contains a short lived positive δ13Cbel peak, was developed at the Lower-Upper Pliensbachian transition. The Upper Pliensbachian represents an outstanding cooling interval containing a positive δ13Cbel excursion interrupted by a small negative δ13Cbel peak. Finally, the Lower Toarcian represented an exceptional warming period pointed as the main responsible for the prominent Lower Toarcian mass extinction.
The size evolution of star-forming and quenched galaxies in the IllustrisTNG simulation
NASA Astrophysics Data System (ADS)
Genel, Shy; Nelson, Dylan; Pillepich, Annalisa; Springel, Volker; Pakmor, Rüdiger; Weinberger, Rainer; Hernquist, Lars; Naiman, Jill; Vogelsberger, Mark; Marinacci, Federico; Torrey, Paul
2018-03-01
We analyse scaling relations and evolution histories of galaxy sizes in TNG100, part of the IllustrisTNG simulation suite. Observational qualitative trends of size with stellar mass, star formation rate and redshift are reproduced, and a quantitative comparison of projected r band sizes at 0 ≲ z ≲ 2 shows agreement to much better than 0.25 dex. We follow populations of z = 0 galaxies with a range of masses backwards in time along their main progenitor branches, distinguishing between main-sequence and quenched galaxies. Our main findings are as follows. (i) At M*, z = 0 ≳ 109.5 M⊙, the evolution of the median main progenitor differs, with quenched galaxies hardly growing in median size before quenching, whereas main-sequence galaxies grow their median size continuously, thus opening a gap from the progenitors of quenched galaxies. This is partly because the main-sequence high-redshift progenitors of quenched z = 0 galaxies are drawn from the lower end of the size distribution of the overall population of main-sequence high-redshift galaxies. (ii) Quenched galaxies with M*, z = 0 ≳ 109.5 M⊙ experience a steep size growth on the size-mass plane after their quenching time, but with the exception of galaxies with M*, z = 0 ≳ 1011 M⊙, the size growth after quenching is small in absolute terms, such that most of the size (and mass) growth of quenched galaxies (and its variation among them) occurs while they are still on the main sequence. After they become quenched, the size growth rate of quenched galaxies as a function of time, as opposed to versus mass, is similar to that of main-sequence galaxies. Hence, the size gap is retained down to z = 0.
NASA Astrophysics Data System (ADS)
Guo, Yonghong; Du, Xiaoze; Yang, Lijun
2018-02-01
Air-cooled condenser is the main equipment of the direct dry cooling system in a power plant, which rejects heat of the exhaust steam with the finned tube bundles. Therefore, the thermo-flow performances of the finned tubes have an important effect on the optimal operation of the direct dry cooling system. In this paper, the flow and heat transfer characteristics of the single row finned tubes with the conventional flat fins and novel jagged fins are investigated by numerical method. The flow and temperature fields of cooling air for the finned tubes are obtained. Moreover, the variations of the flow resistance and average convection heat transfer coefficient under different frontal velocity of air and jag number are presented. Finally, the correlating equations of the friction factor and Nusselt number versus the Reynolds number are fitted. The results show that with increasing the frontal velocity of air, the heat transfer performances of the finned tubes are enhanced but the pressure drop will increase accordingly, resulting in the average convection heat transfer coefficient and friction factor increasing. Meanwhile, with increasing the number of fin jag, the heat transfer performance is intensified. The present studies provide a reference in optimal designing for the air-cooled condenser of direct air cooling system.
Modelling of temperature and perfusion during scalp cooling
NASA Astrophysics Data System (ADS)
Janssen, F. E. M.; Van Leeuwen, G. M. J.; Van Steenhoven, A. A.
2005-09-01
Hair loss is a feared side effect of chemotherapy treatment. It may be prevented by cooling the scalp during administration of cytostatics. The supposed mechanism is that by cooling the scalp, both temperature and perfusion are diminished, affecting drug supply and drug uptake in the hair follicle. However, the effect of scalp cooling varies strongly. To gain more insight into the effect of cooling, a computer model has been developed that describes heat transfer in the human head during scalp cooling. Of main interest in this study are the mutual influences of scalp temperature and perfusion during cooling. Results of the standard head model show that the temperature of the scalp skin is reduced from 34.4 °C to 18.3 °C, reducing tissue blood flow to 25%. Based upon variations in both thermal properties and head anatomies found in the literature, a parameter study was performed. The results of this parameter study show that the most important parameters affecting both temperature and perfusion are the perfusion coefficient Q10 and the thermal resistances of both the fat and the hair layer. The variations in the parameter study led to skin temperature ranging from 10.1 °C to 21.8 °C, which in turn reduced relative perfusion to 13% and 33%, respectively.
NASA Technical Reports Server (NTRS)
Walker, D.; Powell, M. A.; Hays, J. F.; Lofgren, G. E.
1978-01-01
The textural features produced in Stannern, a non-porpyritic representative of the eucrite basaltic achondrite class of meteorite, at differing cooling rates and various degrees of initial superheating were studied. Textures produced from mildly superheated melts were found to be fasciculate rather than porphyritic as the result of the cosaturated bulk chemistry of Stannern. The qualitative type of texture apparently depends mainly on the degree of initial superheating, whereas cooling rate exerts a strong influence on the coarseness of texture. Increasing the degree of superheating produces textures from intergranular/subophitic to fasciculate/porphyritic. With initial superheating to 1200 deg C the transition to quasi-porphyritic is controlled by cooling rate, but the development of phenocrysts is merely an overprint on the fasciculate background texture of the groundmass. The suppression of fasciculate texture is completed by a decrease of the degree of initial superheating below the plagioclast entry and suppression of quasi-porphyritic texture is completed by decrease of the degree of initial superheating below pyroxene entry; these qualitative changes do not seem to be produced by changes of cooling rate. A grain size/cooling rate dependence has been used to deduce the cooling rate of fasciculate-textured Stannern clasts (10.1 to 100 deg C/hr).
NASA Astrophysics Data System (ADS)
Davies, Ben; Crowther, Paul A.; Beasor, Emma R.
2018-05-01
The empirical upper luminosity boundary Lmax of cool supergiants, often referred to as the Humphreys-Davidson limit, is thought to encode information on the general mass-loss behaviour of massive stars. Further, it delineates the boundary at which single stars will end their lives stripped of their hydrogen-rich envelope, which in turn is a key factor in the relative rates of Type-II to Type-Ibc supernovae from single star channels. In this paper we have revisited the issue of Lmax by studying the luminosity distributions of cool supergiants (SGs) in the Large and Small Magellanic Clouds (LMC/SMC). We assemble samples of cool SGs in each galaxy which are highly-complete above log L/L⊙=5.0, and determine their spectral energy distributions from the optical to the mid-infrared using modern multi-wavelength survey data. We show that in both cases Lmax appears to be lower than previously quoted, and is in the region of log L/L⊙=5.5. There is no evidence for Lmax being higher in the SMC than in the LMC, as would be expected if metallicity-dependent winds were the dominant factor in the stripping of stellar envelopes. We also show that Lmax aligns with the lowest luminosity of single nitrogen-rich Wolf-Rayet stars, indicating of a change in evolutionary sequence for stars above a critical mass. From population synthesis analysis we show that the Geneva evolutionary models greatly over-predict the numbers of cool SGs in the SMC. We also argue that the trend of earlier average spectral types of cool SGs in lower metallicity environments represents a genuine shift to hotter temperatures. Finally, we use our new bolometric luminosity measurements to provide updated bolometric corrections for cool supergiants.
NASA Astrophysics Data System (ADS)
Ellison, Sara L.; Sánchez, Sebastian F.; Ibarra-Medel, Hector; Antonio, Braulio; Mendel, J. Trevor; Barrera-Ballesteros, Jorge
2018-02-01
The tight correlation between total galaxy stellar mass and star formation rate (SFR) has become known as the star-forming main sequence. Using ˜487 000 spaxels from galaxies observed as part of the Sloan Digital Sky Survey Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) survey, we confirm previous results that a correlation also exists between the surface densities of star formation (ΣSFR) and stellar mass (Σ⋆) on kpc scales, representing a `resolved' main sequence. Using a new metric (ΔΣSFR), which measures the relative enhancement or deficit of star formation on a spaxel-by-spaxel basis relative to the resolved main sequence, we investigate the SFR profiles of 864 galaxies as a function of their position relative to the global star-forming main sequence (ΔSFR). For galaxies above the global main sequence (positive ΔSFR) ΔΣSFR is elevated throughout the galaxy, but the greatest enhancement in star formation occurs at small radii (<3 kpc, or 0.5Re). Moreover, galaxies that are at least a factor of 3 above the main sequence show diluted gas phase metallicities out to 2Re, indicative of metal-poor gas inflows accompanying the starbursts. For quiescent/passive galaxies that lie at least a factor of 10 below the star-forming main sequence, there is an analogous deficit of star formation throughout the galaxy with the lowest values of ΔΣSFR in the central 3 kpc. Our results are in qualitative agreement with the `compaction' scenario in which a central starburst leads to mass growth in the bulge and may ultimately precede galactic quenching from the inside-out.
Heat control in opto-mechanical system using quantum non-classicality
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Sushamana, E-mail: sushmana.sharma@jietjodhpur.ac.in; Senwar, Subash, E-mail: subashsenwar30@gmail.com
2016-05-06
Cooling of matter to the quantum ground state is a primary directive of quantum control. In other words, to extract entropy from a quantum system, efficient indirect quantum measurements may be implemented. The main objective is the cooling of the oscillator either to its motional ground state or to non-classical states, such as low-number Fock states, squeezed states or entangled states. It is shown that the use of quantum control procedure is better choice for even experimental realizations because it leads to a squeezed steady state with less than one phonon on average. The steady state of system corresponds tomore » cooling of the system.« less
Airfoil for a turbine of a gas turbine engine
Liang, George
2010-12-21
An airfoil for a turbine of a gas turbine engine is provided. The airfoil comprises a main body comprising a wall structure defining an inner cavity adapted to receive a cooling air. The wall structure includes a first diffusion region and at least one first metering opening extending from the inner cavity to the first diffusion region. The wall structure further comprises at least one cooling circuit comprising a second diffusion region and at least one second metering opening extending from the first diffusion region to the second diffusion region. The at least one cooling circuit may further comprise at least one third metering opening, at least one third diffusion region and a fourth diffusion region.
NASA Astrophysics Data System (ADS)
Padrón, Eleazar; Padilla, Germán; Hernández, Pedro A.; Pérez, Nemesio M.; Calvo, David; Nolasco, Dácil; Barrancos, José; Melián, Gladys V.; Dionis, Samara; Rodríguez, Fátima
2013-01-01
We report herein the first results of an extensive soil gas survey performed on Timanfaya volcano on May 2011. Soil gas composition at Timanfaya volcano indicates a main atmospheric source, slightly enriched in CO2 and He. Soil CO2 concentration showed a very slight deep contribution of the Timanfaya volcanic system, with no clear relation to the main eruptive fissures of the studied area. The existence of soil helium enrichments in Timanfaya indicates a shallow degassing of crustal helium and other possible deeper sources probably form cooling magma bodies at depth. The main soil helium enrichments were observed in good agreement with the main eruptive fissures of the 1730-36 eruption, with the highest values located at those areas with a higher density of recent eruptive centers, indicating an important structural control for the leakage of helium at Timanfaya volcano. Atmospheric air slightly polluted by deep-seated helium emissions, CO2 degassed from a cooling magma body, and biogenic CO2, might be the most plausible explanation for the existence of soil gas. Helium is a deep-seated gas, exhibiting important emission rates along the main eruptive fissure of the 1730-36 eruption of Timanfaya volcano.
Begum, Shahanara; Kudo, Kayo; Matsuoka, Yugo; Nakaba, Satoshi; Yamagishi, Yusuke; Nabeshima, Eri; Rahman, Md Hasnat; Nugroho, Widyanto Dwi; Oribe, Yuichiro; Jin, Hyun-O; Funada, Ryo
2016-01-01
Background and Aims In temperate regions, trees undergo annual cycles of cambial growth, with periods of cambial activity and dormancy. Environmental factors might regulate the cambial growth, as well as the development of cambial derivatives. We investigated the effects of low temperature by localized cooling on cambial activity and latewood formation in two conifers, Chamaecyparis obtusa and Cryptomeria japonica. Methods A plastic rubber tube that contained cooled water was wrapped around a 30-cm-wide portion of the main stem of Chamaecyparis obtusa and Cryptomeria japonica trees during seasons of active cambium. Small blocks were collected from both cooled and non-cooled control portions of the stems for sequential observations of cambial activity and for anatomical measurements of cell morphology by light microscopy and image analysis. Key Results The effect of localized cooling was first observed on differentiating tracheids. Tracheids narrow in diameter and with significantly decreased cambial activity were evident 5 weeks after the start of cooling in these stems. Eight weeks after the start of cooling, tracheids with clearly diminished diameters and thickened cell walls were observed in these stems. Thus, localized low temperature induced narrow diameters and obvious thickening of secondary cell walls of tracheids, which were identified as latewood tracheids. Two months after the cessation of cooling, a false annual ring was observed and cambium became active again and produced new tracheids. In Cryptomeria japonica, cambial activity ceased earlier in locally cooled portions of stems than in non-cooled stems, indicating that the cambium had entered dormancy sooner in the cooled stems. Conclusions Artificial cooling of stems induced latewood formation and cessation of cambial activity, indicating that cambium and its derivatives can respond directly to changes in temperature. A decrease in the temperature of the stem is a critical factor in the control of cambial activity and xylem differentiation in trees. PMID:26703452
Begum, Shahanara; Kudo, Kayo; Matsuoka, Yugo; Nakaba, Satoshi; Yamagishi, Yusuke; Nabeshima, Eri; Rahman, Md Hasnat; Nugroho, Widyanto Dwi; Oribe, Yuichiro; Jin, Hyun-O; Funada, Ryo
2016-03-01
In temperate regions, trees undergo annual cycles of cambial growth, with periods of cambial activity and dormancy. Environmental factors might regulate the cambial growth, as well as the development of cambial derivatives. We investigated the effects of low temperature by localized cooling on cambial activity and latewood formation in two conifers, Chamaecyparis obtusa and Cryptomeria japonica. A plastic rubber tube that contained cooled water was wrapped around a 30-cm-wide portion of the main stem of Chamaecyparis obtusa and Cryptomeria japonica trees during seasons of active cambium. Small blocks were collected from both cooled and non-cooled control portions of the stems for sequential observations of cambial activity and for anatomical measurements of cell morphology by light microscopy and image analysis. The effect of localized cooling was first observed on differentiating tracheids. Tracheids narrow in diameter and with significantly decreased cambial activity were evident 5 weeks after the start of cooling in these stems. Eight weeks after the start of cooling, tracheids with clearly diminished diameters and thickened cell walls were observed in these stems. Thus, localized low temperature induced narrow diameters and obvious thickening of secondary cell walls of tracheids, which were identified as latewood tracheids. Two months after the cessation of cooling, a false annual ring was observed and cambium became active again and produced new tracheids. In Cryptomeria japonica, cambial activity ceased earlier in locally cooled portions of stems than in non-cooled stems, indicating that the cambium had entered dormancy sooner in the cooled stems. Artificial cooling of stems induced latewood formation and cessation of cambial activity, indicating that cambium and its derivatives can respond directly to changes in temperature. A decrease in the temperature of the stem is a critical factor in the control of cambial activity and xylem differentiation in trees. © The Author 2015. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Structural-Phase Transformations of CuZn Alloy Under Thermal-Impact Cycling
NASA Astrophysics Data System (ADS)
Potekaev, A. I.; Chaplygina, A. A.; Kulagina, V. V.; Chaplygin, P. A.; Starostenkov, M. D.; Grinkevich, L. S.
2017-02-01
Using the Monte Carlo method, special features of structural - phase transformations in β-brass are investigated during thermal impact using thermal cycling as an example (a number of successive order - disorder and disorder - order phase transitions in the course of several heating - cooling cycles). It is shown that a unique hysteresis is observed after every heating and cooling cycle, whose presence indicates irreversibility of the processes, which suggests a difference in the structural - phase states both in the heating and cooling stages. A conclusion is drawn that the structural - phase transformations in the heating and cooling stages occur within different temperature intervals, where the thermodynamic stimuli of one or the other structural - phase state are low. This is also demonstrated both in the plots of configurational energy, long- and short-range order parameter, atomic structure variations, and structural - phase state distributions. Simultaneously, there coexist ordered and disordered phases and a certain collection of superstructure domains. This implies the presence of low - stability states in the vicinity of the order - disorder phase transition. The results of investigations demonstrate that the structural - phase transitions within two successive heating and cooling cycles at the same temperature are different in both stages. These changes, though not revolutionary, occur in every cycle and decrease with the increasing cycle number. In fact, the system undergoes training with a tendency towards a certain sequence of structural - phase states.
Solid-state transformations in the β-form of chlorpropamide on cooling to 100 K.
Drebushchak, Tatiana N; Drebushchak, Valeri A; Boldyreva, Elena V
2011-04-01
A single-crystal X-ray diffraction study of the effect of cooling down to 100 K on the β-form of chlorpropamide, 4-chloro-N-(propylaminocarbonyl)benzenesulfonamide, has revealed reversible phase transitions at ∼257 K and between 150 and 125 K: β (Pbcn, Z' = 1) ⇔ β(II) (P2/c, Z' = 2) ⇔ β(III) (P2/n, a' = 2a, Z' = 4); the sequence corresponds to cooling. Despite changes in the space group and number of symmetry-independent molecules, the volume per molecule changes continuously in the temperature range 100-300 K. The phase transition at ∼257 K is accompanied by non-merohedral twinning, which is preserved on further cooling and through the second phase transition, but the original single crystal does not crack. DSC (differential scanning calorimetry) and X-ray powder diffraction investigations confirm the phase transitions. Twinning disappears on heating as the reverse transformations take place. The second phase transition is related to a change in conformation of the alkyl tail from trans to gauche in 1/4 of the molecules, regularly distributed in the space. Possible reasons for the increase in Z' upon cooling are discussed in comparison to other reported examples of processes (crystallization, phase transitions) in which organic crystals with Z' > 1 have been formed. Implications for pharmaceutical applications are discussed. © 2011 International Union of Crystallography
UV observations of blue stragglers and population 2 K dwarfs
NASA Technical Reports Server (NTRS)
Carney, B. W.; Bond, H. E.
1986-01-01
Blue stragglers are stars, found usually in either open or globular clusters, that appear to lie on the main sequence, but are brighter and bluer than the cluster turn-off. Currently, two rival models are invoked to explain this apparently pathological behavior: internal mixing (so that fresh fuel is brought into the stellar core); and mass transfer (by which a normal main sequence star acquires mass from an evolving nearby companion and so moves up the main sequence). The latter model predicts that in the absence of complete mass transfer (i.e., coalescence), blue stragglers should be binary systems with the fainter star in a post-main sequence evolutionary state. It is important to ascertain the cause of this phenomenon since stellar evolution models of main sequence stars play such a vital role in astronomy. If mass transfer is involved, one may easily exclude binaries from age determinations of clusters, but if mixing is the cause, our age determinations will be much less accurate unless we can determine whether all stars or only some mix, and what causes the mixing to occur at all.
The Role Of Rejuvenation In Shaping The High-Mass End Of The Main Sequence
NASA Astrophysics Data System (ADS)
Mancini, Chiara
2017-06-01
We investigate the nature of star forming galaxies with reduced specific SFRs and high stellar masses, those that seemingly cause the so-called bending of the main sequence. The fact that such objects host large bulges recently lead some to suggest that the internal formation of the bulges, via compaction or disk instabilities, was the late event that induced sSFRs of massive galaxies to drop in a slow downfall and thus the main sequence to bend. We have studied in detail a sample of 16 galaxies at 0.5
Pressure intelligent control strategy of Waste heat recovery system of converter vapors
NASA Astrophysics Data System (ADS)
Feng, Xugang; Wu, Zhiwei; Zhang, Jiayan; Qian, Hong
2013-01-01
The converter gas evaporative cooling system is mainly used for absorbing heat in the high temperature exhaust gas which produced by the oxygen blowing reaction. Vaporization cooling steam pressure control system of converter is a nonlinear, time-varying, lagging behind, close coupling of multivariable control object. This article based on the analysis of converter operation characteristics of evaporation cooling system, of vaporization in a production run of pipe pressure variation and disturbance factors.For the dynamic characteristics of the controlled objects,we have improved the conventional PID control scheme.In Oxygen blowing process, we make intelligent control by using fuzzy-PID cascade control method and adjusting the Lance,that it can realize the optimization of the boiler steam pressure control.By design simulation, results show that the design has a good control not only ensures drum steam pressure in the context of security, enabling efficient conversion of waste heat.And the converter of 1800 flue gas through pipes and cool and dust removal also can be cooled to about 800. Therefore the converter haze evaporative cooling system has achieved to the converter haze temperature decrease effect and enhanced to the coal gas returns-ratio.
Solar cooling - comparative study between thermal and electrical use in industrial buildings
NASA Astrophysics Data System (ADS)
Badea, N.; Badea, G. V.; Epureanu, A.; Frumuşanu, G.
2016-08-01
The increase in the share of renewable energy sources together with the emphasis on the need for energy security bring to a spotlight the field of trigeneration autonomous microsystems, as a solution to cover the energy consumptions, not only for isolated industrial buildings, but also for industrial buildings located in urban areas. The use of solar energy for cooling has been taken into account to offer a cooling comfort in the building. Cooling and air- conditioned production are current applications promoting the use of solar energy technologies. Solar cooling systems can be classified, depending on the used energy, in electrical systems using mechanical compression chillers and systems using thermal compression by absorption or adsorption. This comparative study presents the main strengths and weaknesses of solar cooling obtained: i) through the transformation of heat resulted from thermal solar panels combined with adsorption chillers, and ii) through the multiple conversion of electricity - photovoltaic panels - battery - inverter - combined with mechanical compression chillers. Both solutions are analyzed from the standpoints of energy efficiency, dynamic performances (demand response), and costs sizes. At the end of the paper, experimental results obtained in the climatic condition of Galafi city, Romania, are presented.
Analysis of film cooling in rocket nozzles
NASA Technical Reports Server (NTRS)
Woodbury, Keith A.; Karr, Gerald R.
1992-01-01
Progress during the reporting period is summarized. Analysis of film cooling in rocket nozzles by computational fluid dynamics (CFD) computer codes is desirable for two reasons. First, it allows prediction of resulting flow fields within the rocket nozzle, in particular the interaction of the coolant boundary layer with the main flow. This facilitates evaluation of potential cooling configurations with regard to total thrust, etc., before construction and testing of any prototype. Secondly, CFD simulation of film cooling allows for assessment of the effectiveness of the proposed cooling in limiting nozzle wall temperature rises. This latter objective is the focus of the current work. The desired objective is to use the Finite Difference Navier Stokes (FDNS) code to predict wall heat fluxes or wall temperatures in rocket nozzles. As prior work has revealed that the FDNS code is deficient in the thermal modeling of boundary conditions, the first step is to correct these deficiencies in the FDNS code. Next, these changes must be tested against available data. Finally, the code will be used to model film cooling of a particular rocket nozzle. The third task of this research, using the modified code to compute the flow of hot gases through a nozzle, is described.
Lobato, I; Rojas, J; Landauro, C V; Torres, J
2009-02-04
The structural evolution and dynamics of silver nanodrops Ag(2869) (4.4 nm in diameter) under rapid cooling conditions have been studied by means of molecular dynamics simulations and electronic density of state calculations. The interaction of silver atoms is modelled by a tight-binding semiempirical interatomic potential proposed by Cleri and Rosato. The pair correlation functions and the pair analysis technique are used to reveal the structural transition in the process of solidification. It is shown that Ag nanoparticles evolve into different nanostructures under different cooling processes. At a cooling rate of 1.5625 × 10(13) K s(-1) the nanoparticles preserve an amorphous-like structure containing a large amount of 1551 and 1541 pairs which correspond to icosahedral symmetry. For a lower cooling rate (1.5625 × 10(12) K s(-1)), the nanoparticles transform into a crystal-like structure consisting mainly of 1421 and 1422 pairs which correspond to the face centred cubic and hexagonal close packed structures, respectively. The variations of the electronic density of states for the differently cooled nanoparticles are small, but in correspondence with the structural changes.
Adiabatic cooling processes in frustrated magnetic systems with pyrochlore structure
NASA Astrophysics Data System (ADS)
Jurčišinová, E.; Jurčišin, M.
2017-11-01
We investigate in detail the process of adiabatic cooling in the framework of the exactly solvable antiferromagnetic spin-1/2 Ising model in the presence of the external magnetic field on an approximate lattice with pyrochlore structure. The behavior of the entropy of the model is studied and exact values of the residual entropies of all ground states are found. The temperature variation of the system under adiabatic (de)magnetization is investigated and the central role of the macroscopically degenerated ground states in cooling processes is explicitly demonstrated. It is shown that the model parameter space of the studied geometrically frustrated system is divided into five disjunct regions with qualitatively different processes of the adiabatic cooling. The effectiveness of the adiabatic (de)magnetization cooling in the studied model is compared to the corresponding processes in paramagnetic salts. It is shown that the processes of the adiabatic cooling in the antiferromagnetic frustrated systems are much more effective especially in nonzero external magnetic fields. It means that the frustrated magnetic materials with pyrochlore structure can be considered as very promising refrigerants mainly in the situations with nonzero final values of the magnetic field.
Adiabatic cooling processes in frustrated magnetic systems with pyrochlore structure.
Jurčišinová, E; Jurčišin, M
2017-11-01
We investigate in detail the process of adiabatic cooling in the framework of the exactly solvable antiferromagnetic spin-1/2 Ising model in the presence of the external magnetic field on an approximate lattice with pyrochlore structure. The behavior of the entropy of the model is studied and exact values of the residual entropies of all ground states are found. The temperature variation of the system under adiabatic (de)magnetization is investigated and the central role of the macroscopically degenerated ground states in cooling processes is explicitly demonstrated. It is shown that the model parameter space of the studied geometrically frustrated system is divided into five disjunct regions with qualitatively different processes of the adiabatic cooling. The effectiveness of the adiabatic (de)magnetization cooling in the studied model is compared to the corresponding processes in paramagnetic salts. It is shown that the processes of the adiabatic cooling in the antiferromagnetic frustrated systems are much more effective especially in nonzero external magnetic fields. It means that the frustrated magnetic materials with pyrochlore structure can be considered as very promising refrigerants mainly in the situations with nonzero final values of the magnetic field.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schulman, Al
2009-08-09
Three subfamilies of grasses, the Erhardtoideae (rice), the Panicoideae (maize, sorghum, sugar cane and millet), and the Pooideae (wheat, barley and cool season forage grasses) provide the basis of human nutrition and are poised to become major sources of renewable energy. Here we describe the complete genome sequence of the wild grass Brachypodium distachyon (Brachypodium), the first member of the Pooideae subfamily to be completely sequenced. Comparison of the Brachypodium, rice and sorghum genomes reveals a precise sequence- based history of genome evolution across a broad diversity of the grass family and identifies nested insertions of whole chromosomes into centromericmore » regions as a predominant mechanism driving chromosome evolution in the grasses. The relatively compact genome of Brachypodium is maintained by a balance of retroelement replication and loss. The complete genome sequence of Brachypodium, coupled to its exceptional promise as a model system for grass research, will support the development of new energy and food crops« less
Thermohydraulic behavior of the liquid metal target of a spallation neutron source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takeda, Y.
1996-06-01
The author presents work done on three main problems. (1) Natural circulation in double coaxial cylindircal container: The thermohydraulic behaviour of the liquid metal target of the spallation neutron source at PSI has been investigated. The configuration is a natural-circulation loop in a concentric double-tube-type container. The results show that the natural-circulation loop concept is valid for the design phase of the target construction, and the current specified design criteria will be fulfilled with the proposed parameter values. (2) Flow around the window: Water experiments were performed for geometry optimisation of the window shape of the SINQ container for avoidingmore » generating recirculation zones at peripheral area and the optimal cooling of the central part of the beam entrance window. Flow visualisation technique was mainly used for various window shapes, gap distance between the window and the guide tube edge. (3) Flow in window cooling channels: Flows in narrow gaps of cooling channels of two different types of windows were studied by flow visualisation techniques. One type is a slightly curved round cooling channel and the other is hemispherical shape, both of which have only 2 mm gap distance and the water inlet is located on one side and flows out from the opposite side. In both cases, the central part of the flow area has lower velocity than peripheral area.« less
Preburner of Staged Combustion Rocket Engine
NASA Technical Reports Server (NTRS)
Yost, M. C.
1978-01-01
A regeneratively cooled LOX/hydrogen staged combustion assembly system with a 400:1 expansion area ratio nozzle utilizing an 89,000 Newton (20,000 pound) thrust regeneratively cooled thrust chamber and 175:1 tubular nozzle was analyzed, assembled, and tested. The components for this assembly include two spark/torch oxygen-hydrogen igniters, two servo-controlled LOX valves, a preburner injector, a preburner combustor, a main propellant injector, a regeneratively cooled combustion chamber, a regeneratively cooled tubular nozzle with an expansion area ratio of 175:1, an uncooled heavy-wall steel nozzle with an expansion area ratio of 400:1, and interconnecting ducting. The analytical effort was performed to optimize the thermal and structural characteristics of each of the new components and the ducting, and to reverify the capabilities of the previously fabricated components. The testing effort provided a demonstration of the preburner/combustor chamber operation, chamber combustion efficiency and stability, and chamber and nozzle heat transfer.
Performance of a 10-kJ SMES model cooled by liquid hydrogen thermo-siphon flow for ASPCS study
NASA Astrophysics Data System (ADS)
Makida, Y.; Shintomi, T.; Hamajima, T.; Ota, N.; Katsura, M.; Ando, K.; Takao, T.; Tsuda, M.; Miyagi, D.; Tsujigami, H.; Fujikawa, S.; Hirose, J.; Iwaki, K.; Komagome, T.
2015-12-01
We propose a new electrical power storage and stabilization system, called an Advanced Superconducting Power Conditioning System (ASPCS), which consists of superconducting magnetic energy storage (SMES) and hydrogen energy storage, converged on a liquid hydrogen station for fuel cell vehicles. A small 10- kJ SMES system, in which a BSCCO coil cooled by liquid hydrogen was installed, was developed to create an experimental model of an ASPCS. The SMES coil is conductively cooled by liquid hydrogen flow through a thermo-siphon line under a liquid hydrogen buffer tank. After fabrication of the system, cooldown tests were carried out using liquid hydrogen. The SMES coil was successfully charged up to a nominal current of 200 A. An eddy current loss, which was mainly induced in pure aluminum plates pasted onto each pancake coils for conduction cooling, was also measured.
USDA-ARS?s Scientific Manuscript database
Basal stalk rot (BSR) caused by the ascomycete fungus Sclerotinia sclerotiorum (Lib.) de Bary is a serious disease of sunflower (Helianthus annuus L.) in the cool and humid production areas of the world. Quantitative trait loci (QTL) for BSR resistance were identified in a sunflower recombinant inbr...
Hot-Jupiter Breakfasts Realign Stars
NASA Astrophysics Data System (ADS)
Kohler, Susanna
2015-08-01
Two researchers at the University of Chicago have recently developed a new theory to explain an apparent dichotomy in the orbits of planets around cool vs. hot stars. Their model proposes that the spins of cool stars are affected when they ingest hot Jupiters (HJs) early in their stellar lifetimes. A Puzzling Dichotomy: In exoplanet studies, there is a puzzling difference observed between planet orbits around cool and hot (those with Teff ≥ 6250 K) stars: the orbital planes of planets around cool stars are primarily aligned with the host star's spin, whereas the orbital planes of planets around hot stars seem to be randomly distributed. Previous attempts to explain this dichotomy have focused on tidal interactions between the host star and the planets observed in the system. Now Titos Matsakos and Arieh Königl have taken these models a step further — by including in their calculations not only the effects of observed planets, but also those of HJs that may have been swallowed by the star long before we observed the systems. Modeling Meals: Plots of the distribution of the obliquity λ for hot Jupiters around cool hosts (upper plot) and hot hosts (lower plot). The dashed line shows the initial distribution, the bins show the model prediction for the final distribution after the systems evolve, and the black dots show the current observational data. [Matsakos & Königl, 2015]" class="size-thumbnail wp-image-223" height="386" src="http://aasnova.org/wp-content/uploads/2015/08/fig22-260x386.png" width="260" /> Plots of the distribution of the obliquity λ for hot Jupiters around cool hosts (upper plot) and hot hosts (lower plot). The dashed line shows the initial distribution, the bins show the model prediction for the final distribution after the systems evolve, and the black dots show the current observational data. [Matsakos & Königl, 2015] The authors' model assumes that as HJs are formed and migrate inward through the protoplanetary disk, they stall out near the star (where they have periods of ~2 days) and get stranded as the gas disk evaporates around them. Tidal interactions can cause these planets to become ingested by the host star within 1 Gyr. Using Monte Carlo simulations, the authors model these star-planet tidal interactions and evolve a total of 10^6 systems: half with hot (Teff = 6400 K), main-sequence hosts, and half with cool (Teff = 5500 K), solar-type hosts. The initial obliquities — the angle between the stellar spin and the planets' orbital angular momentum vectors — are randomly distributed between 0° and 180°. The authors find that early stellar ingestion of planets might be very common: to match observations, roughly half of all stellar hosts must ingest an HJ early in their lifetimes! This scenario results in a good match with observational data: about 50% of cool hosts' spins become roughly aligned with the orbital plane of their planets after they absorb the orbital angular momentum of the HJ they ingest. Hot stars, on the other hand, generally retain their random distributions of obliquity, because their angular momentum is typically higher than the orbital angular momentum of the ingested planet. Citation: Titos Matsakos and Arieh Königl 2015, ApJ, 809, L20. doi: 10.1088/2041-8205/809/2/L20
The Star-forming Main Sequence of Dwarf Low Surface Brightness Galaxies
NASA Astrophysics Data System (ADS)
McGaugh, Stacy S.; Schombert, James M.; Lelli, Federico
2017-12-01
We explore the star-forming properties of late-type, low surface brightness (LSB) galaxies. The star-forming main sequence ({SFR}-{M}* ) of LSB dwarfs has a steep slope, indistinguishable from unity (1.04 ± 0.06). They form a distinct sequence from more massive spirals, which exhibit a shallower slope. The break occurs around {M}* ≈ {10}10 {M}⊙ , and can also be seen in the gas mass—stellar mass plane. The global Kennicutt-Schmidt law ({SFR}-{M}g) has a slope of 1.47 ± 0.11 without the break seen in the main sequence. There is an ample supply of gas in LSB galaxies, which have gas depletion times well in excess of a Hubble time, and often tens of Hubble times. Only ˜ 3 % of this cold gas needs be in the form of molecular gas to sustain the observed star formation. In analogy with the faint, long-lived stars of the lower stellar main sequence, it may be appropriate to consider the main sequence of star-forming galaxies to be defined by thriving dwarfs (with {M}* < {10}10 {M}⊙ ), while massive spirals (with {M}* > {10}10 {M}⊙ ) are weary giants that constitute more of a turn-off population.
Okutsu, Noriya; Morohoshi, Tomohiro; Xie, Xiaonan; Kato, Norihiro; Ikeda, Tsukasa
2015-12-30
The cooling water systems are used to remove heat generated in the various industries. Biofouling of the cooling water systems causes blocking of condenser pipes and the heat exchanger tubes. In many Gram-negative bacteria, N-acylhomoserine lactone (AHL) are used as quorum-sensing signal molecule and associated with biofilm formation. To investigate the relationship between quorum sensing and biofouling in the cooling water system, we isolated a total of 192 bacterial strains from the five cooling water systems, and screened for AHL production. Seven isolates stimulated AHL-mediated purple pigment production in AHL reporter strain Chromobacterium violaceum CV026 or VIR07. Based on their 16S rRNA gene sequences, AHL-producing isolates were assigned to Aeromonas hydrophila, Lysobacter sp., Methylobacterium oryzae, and Bosea massiliensis. To the best of our knowledge, B. massiliensis and Lysobacter sp. have not been reported as AHL-producing species in the previous researches. AHLs extracted from the culture supernatants of B. massiliensis and Lysobacter sp. were identified by liquid chromatography-mass spectrometry. AHLs produced by B. massiliensis were assigned as N-hexanoyl-L-homoserine lactone (C6-HSL), N-(3-oxohexanoyl)-L-homoserine lactone (3-oxo-C6-HSL), and N-(3-oxooctanoyl)-L-homoserine lactone (3-oxo-C8-HSL). AHLs produced by Lysobacter sp. were assigned as N-decanoyl-L-homoserine lactone (C10-HSL) and N-(3-oxodecanoyl)-L-homoserine lactone (3-oxo-C10-HSL). This is the first report of identification of AHLs produced by B. massiliensis and Lysobacter sp. isolated from the cooling water system.
Naresh, Sai
2016-02-01
Semen cryopreservation is broadly utilized as a part of the bovine reproducing industry, a large portion of the spermatozoa does not survive and the majority of those that do survive experience various molecular and physiological changes that influence their fertilizing capacity. The main aim of this study is to determine the effect of cooling (4 °C) and cryopreservation on cytoskeleton actin, tyrosine phosphorylation and quality of buffalo spermatozoa, and to determine the similarity between in vitro capacitation and cryopreservation induced capacitation like changes. To achieve this, Western blot was used to examine the changes in actin expression and protein tyrosine phosphorylation, whereas changes in actin polymerization, localization of actin and protein tyrosine phosphorylation during capacitation and cryopreservation were evaluated by indirect immunofluorescence technique. Localization studies revealed that the actin localized to flagella and acrosome membrane regions and following, capacitation it migrated towards the acrosome region of sperm. Time dependent increase in actin polymerization and protein tyrosine phosphorylation was observed during in vitro capacitation. The cooling phase (4 °C) and cryopreservation processes resulted in the loss/damage of cytoskeleton actin. In addition, we performed the actin polymerization and protein tyrosine phosphorylation in cooled and cryopreserved buffalo spermatozoa. Interestingly, cooling and cryopreservation induces actin polymerization and protein tyrosine phosphorylation, which were similar to in vitro capacitation (cryo-capacitation). These changes showed 1.3 folds reduction in the sperm quality parameters which includes motility, viability and plasma membrane integrity. Furthermore, our findings indicate that cooling and cryopreservation damages the cytoskeleton actin and also induces capacitation like changes such as protein tyrosine phosphorylation and actin polymerization. This could be one of the main reasons for reduced sperm quality and fertility failure of cryopreserved spermatozoa. Copyright © 2015 Elsevier Inc. All rights reserved.
Photometric binary stars in Praesepe and the search for globular cluster binaries
NASA Technical Reports Server (NTRS)
Bolte, Michael
1991-01-01
A radial velocity study of the stars which are located on a second sequence above the single-star zero-age main sequence at a given color in the color-magnitude diagram of the open cluster Praesepe, (NGC 2632) shows that 10, and possibly 11, of 17 are binary systems. Of the binary systems, five have full amplitudes for their velocity variations that are greater than 50 km/s. To the extent that they can be applied to globular clusters, these results suggests that (1) observations of 'second-sequence' stars in globular clusters would be an efficient way of finding main-sequence binary systems in globulars, and (2) current instrumentation on large telescopes is sufficient for establishing unambiguously the existence of main-sequence binary systems in nearby globular clusters.
Heat transfer in rocket engine combustion chambers and regeneratively cooled nozzles
NASA Technical Reports Server (NTRS)
1993-01-01
A conjugate heat transfer computational fluid dynamics (CFD) model to describe regenerative cooling in the main combustion chamber and nozzle and in the injector faceplate region for a launch vehicle class liquid rocket engine was developed. An injector model for sprays which treats the fluid as a variable density, single-phase media was formulated, incorporated into a version of the FDNS code, and used to simulate the injector flow typical of that in the Space Shuttle Main Engine (SSME). Various chamber related heat transfer analyses were made to verify the predictive capability of the conjugate heat transfer analysis provided by the FDNS code. The density based version of the FDNS code with the real fluid property models developed was successful in predicting the streamtube combustion of individual injector elements.
Drivers of Antarctic sea-ice expansion and Southern Ocean surface cooling over the past four decades
NASA Astrophysics Data System (ADS)
Purich, Ariaan; England, Matthew
2017-04-01
Despite global warming, total Antarctic sea-ice coverage has increased overall during the past four decades. In contrast, the majority of CMIP5 models simulate a decline. In addition, Southern Ocean surface waters have largely cooled, in stark contrast to almost all historical CMIP5 simulations. Subantarctic Surface Waters have cooled and freshened while waters to the north of the Antarctic Circumpolar Current have warmed and increased in salinity. It remains unclear as to what extent the cooling and Antarctic sea-ice expansion is due to natural variability versus anthropogenic forcing; due for example to changes in the Southern Annular Mode (SAM). It is also unclear what the respective role of surface buoyancy fluxes is compared to internal ocean circulation changes, and what the implications are for longer-term climate change in the region. In this presentation we will outline three distinct drivers of recent Southern Ocean surface trends that have each made a significant contribution to regional cooling: (1) wind-driven surface cooling and sea-ice expansion due to shifted westerly winds, (2) teleconnections of decadal variability from the tropical Pacific, and (3) surface cooling and ice expansion due to large-scale Southern Ocean freshening, most likely driven by SAM-related precipitation trends over the open ocean. We will also outline the main reasons why climate models for the most part miss these Southern Ocean cooling trends, despite capturing overall trends in the SAM.
Film-cooling effectiveness with developing coolant flow through straight and curved tubular passages
NASA Technical Reports Server (NTRS)
Papell, S. S.; Wang, C. R.; Graham, R. W.
1982-01-01
The data were obtained with an apparatus designed to determine the influence of tubular coolant passage curvature on film-cooling performance while simulating the developing flow entrance conditions more representative of cooled turbine blade. Data comparisons were made between straight and curved single tubular passages embedded in the wall and discharging at 30 deg angle in line with the tunnel flow. The results showed an influence of curvature on film-cooling effectiveness that was inversely proportional to the blowing rate. At the lowest blowing rate of 0.18, curvature increased the effectiveness of film cooling by 35 percent; but at a blowing rate of 0.76, the improvement was only 10 percent. In addition, the increase in film-cooling area coverage ranged from 100 percent down to 25 percent over the same blowing rates. A data trend reversal at a blowing rate of 1.5 showed the straight tubular passage's film-cooling effectiveness to be 20 percent greater than that of the curved passage with about 80 percent more area coverage. An analysis of turbulence intensity detain the mixing layer in terms of the position of the mixing interface relative to the wall supported the concept that passage curvature tends to reduce the diffusion of the coolant jet into the main stream at blowing rates below about. Explanations for the film-cooling performance of both test sections were made in terms differences in turbulences structure and in secondary flow patterns within the coolant jets as influenced by flow passage geometry.
Film-cooling effectiveness with developing coolant flow through straight and curved tubular passages
NASA Astrophysics Data System (ADS)
Papell, S. S.; Wang, C. R.; Graham, R. W.
1982-11-01
The data were obtained with an apparatus designed to determine the influence of tubular coolant passage curvature on film-cooling performance while simulating the developing flow entrance conditions more representative of cooled turbine blade. Data comparisons were made between straight and curved single tubular passages embedded in the wall and discharging at 30 deg angle in line with the tunnel flow. The results showed an influence of curvature on film-cooling effectiveness that was inversely proportional to the blowing rate. At the lowest blowing rate of 0.18, curvature increased the effectiveness of film cooling by 35 percent; but at a blowing rate of 0.76, the improvement was only 10 percent. In addition, the increase in film-cooling area coverage ranged from 100 percent down to 25 percent over the same blowing rates. A data trend reversal at a blowing rate of 1.5 showed the straight tubular passage's film-cooling effectiveness to be 20 percent greater than that of the curved passage with about 80 percent more area coverage. An analysis of turbulence intensity detain the mixing layer in terms of the position of the mixing interface relative to the wall supported the concept that passage curvature tends to reduce the diffusion of the coolant jet into the main stream at blowing rates below about. Explanations for the film-cooling performance of both test sections were made in terms differences in turbulences structure and in secondary flow patterns within the coolant jets as influenced by flow passage geometry.
Large Eddy Simulation of a Film Cooling Technique with a Plenum
NASA Astrophysics Data System (ADS)
Dharmarathne, Suranga; Sridhar, Narendran; Araya, Guillermo; Castillo, Luciano; Parameswaran, Sivapathasund
2012-11-01
Factors that affect the film cooling performance have been categorized into three main groups: (i) coolant & mainstream conditions, (ii) hole geometry & configuration, and (iii) airfoil geometry Bogard et al. (2006). The present study focuses on the second group of factors, namely, the modeling of coolant hole and the plenum. It is required to simulate correct physics of the problem to achieve more realistic numerical results. In this regard, modeling of cooling jet hole and the plenum chamber is highly important Iourokina et al. (2006). Substitution of artificial boundary conditions instead of correct plenum design would yield unrealistic results Iourokina et al. (2006). This study attempts to model film cooling technique with a plenum using a Large Eddy Simulation.Incompressible coolant jet ejects to the surface of the plate at an angle of 30° where it meets compressible turbulent boundary layer which simulates the turbine inflow conditions. Dynamic multi-scale approach Araya (2011) is introduced to prescribe turbulent inflow conditions. Simulations are carried out for two different blowing ratios and film cooling effectiveness is calculated for both cases. Results obtained from LES will be compared with experimental results.
Counter-Flow Cooling Tower Test Cell
NASA Astrophysics Data System (ADS)
Dvořák, Lukáš; Nožička, Jiří
2014-03-01
The article contains a design of a functional experimental model of a cross-flow mechanical draft cooling tower and the results and outcomes of measurements. This device is primarily used for measuring performance characteristics of cooling fills, but with a simple rebuild, it can be used for measuring other thermodynamic processes that take part in so-called wet cooling. The main advantages of the particular test cell lie in the accuracy, size, and the possibility of changing the water distribution level. This feature is very useful for measurements of fills of different heights without the influence of the spray and rain zone. The functionality of this test cell has been verified experimentally during assembly, and data from the measurement of common film cooling fills have been compared against the results taken from another experimental line. For the purpose of evaluating the data gathered, computational scripts were created in the MATLAB numerical computing environment. The first script is for exact calculation of the thermal balance of the model, and the second is for determining Merkel's number via Chebyshev's method.
Effect of Fin Passage Length on Optimization of Cylinder Head Cooling Fins
NASA Technical Reports Server (NTRS)
Siegel, R.; Graham, R. W.
1977-01-01
The heat transfer performance of baffled cooling fins on cylinder heads of small, air-cooled, general-aviation aircraft engines was analyzed to determine the potential for improving cooling fin design. Flow baffles were assumed to be installed tightly against the fin end edges, an ideal baffle configuration for guiding all flow between the fins. A rectangular flow passage is thereby formed between each set of two adjacent fins, the fin base surface, and the baffle. These passages extend around each side of the cylinder head, and the cooling air absorbs heat as it flows within them. For each flow passage length, the analysis was concerned with optimizing fin spacing and thickness to achieve the best heat transfer for each fin width. Previous literature has been concerned mainly with maximizing the local fin conductance and has not considered the heating of the gas in the flow direction, which leads to higher wall temperatures at the fin passage exits. If the fins are close together, there is a large surface area, but the airflow is restricted.
Lu, W; Xiong, B; Zhang, X Z; Sun, L T; Feng, Y C; Ma, B H; Guo, S Q; Cao, R; Ruan, L; Zhao, H W
2014-02-01
A new room temperature ECR ion source, Lanzhou Electron Cyclotron Resonance ion source No. 4 (LECR4, previously named DRAGON), is under intense construction at Institute of Modern Physics. LECR4 is designed to operate with 18 GHz microwave frequency. The maximum axial magnetic fields are 2.3 T at injection and 1.3 T at extraction, and the radial field at the plasma chamber wall of 76 mm inner diameter is 1.0-1.2 T. One of the unique features for LECR4 is that its axial solenoids are winded with solid square copper wires which are immersed in a kind of special evaporative cooling medium for cooling purpose. Till now, a prototype of the cooling system has been successfully constructed and tested, which has demonstrated that the cooling efficiency of the designed system could meet the requirements of LECR4 under the routine operation conditions. All the main components of the ion source have been completed. Assembly and commissioning is ongoing. The latest developments and test results will be presented in this paper.
Laser cooling of nuclear spin 0 alkali 78Rb
NASA Astrophysics Data System (ADS)
Behr, J. A.; Gorelov, A.; Anholm, M.
2015-05-01
The textbook example for sub-Doppler cooling is a J = 1/2 I = 0 alkali atom in lin ⊥ lin molasses. In the σ+ σ- configuration of a standard MOT, the main sub-Doppler cooling mechanism relies on changing alignment (MF2 population) with the summed linear polarization orientation, but there is no such variation in AC Stark shift for F = 1/2. We have nevertheless looked for signs of sub-Doppler cooling by trapping I = 0 78Rb in a standard MOT and measuring the cloud size as a function of laser detuning and intensity. The 78Rb cloud size does not change significantly with lowered intensity, and expands slightly with detuning, consistent with minimal to no sub-Doppler cooling. Our geometry does show the well-known substantially smaller cloud size with detuning and intensity for I = 3/2 87Rb. Maintaining an I = 0 alkali cloud size with lowered intensity will help our planned β- ν correlation experiments in 38mK decay by suppressing possible production of photoassisted dimers. Supported by NSERC and NRC Canada through TRIUMF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, M.; Sullivan, M.; D’Andrea, C. B.
2016-02-03
We present DES14X3taz, a new hydrogen-poor superluminous supernova (SLSN-I) discovered by the Dark Energy Survey (DES) supernova program, with additional photometric data provided by the Survey Using DECam for Superluminous Supernovae. Spectra obtained using Optical System for Imaging and low-Intermediate-Resolution Integrated Spectroscopy on the Gran Telescopio CANARIAS show DES14X3taz is an SLSN-I at z = 0.608. Multi-color photometry reveals a double-peaked light curve: a blue and relatively bright initial peak that fades rapidly prior to the slower rise of the main light curve. Our multi-color photometry allows us, for the first time, to show that the initial peak cools frommore » 22,000 to 8000 K over 15 rest-frame days, and is faster and brighter than any published core-collapse supernova, reaching 30% of the bolometric luminosity of the main peak. No physical Ni-56-powered model can fit this initial peak. We show that a shock-cooling model followed by a magnetar driving the second phase of the light curve can adequately explain the entire light curve of DES14X3taz. Models involving the shock-cooling of extended circumstellar material at a distance of similar or equal to 400 R-circle dot are preferred over the cooling of shock-heated surface layers of a stellar envelope. We compare DES14X3taz to the few double-peaked SLSN-I events in the literature. Although the rise. times and characteristics of these initial peaks differ, there exists the tantalizing possibility that they can be explained by one physical interpretation« less
Smith, M.
2016-02-03
Here, we present DES14X3taz, a new hydrogen-poor superluminous supernova (SLSN-I) discovered by the Dark Energy Survey (DES) supernova program, with additional photometric data provided by the Survey Using DECam for Superluminous Supernovae. Spectra obtained using Optical System for Imaging and low-Intermediate-Resolution Integrated Spectroscopy on the Gran Telescopio CANARIAS show DES14X3taz is an SLSN-I at z = 0.608. Multi-color photometry reveals a double-peaked light curve: a blue and relatively bright initial peak that fades rapidly prior to the slower rise of the main light curve. Our multi-color photometry allows us, for the first time, to show that the initial peak cools from 22,000more » to 8000 K over 15 rest-frame days, and is faster and brighter than any published core-collapse supernova, reaching 30% of the bolometric luminosity of the main peak. No physical (56)Ni-powered model can fit this initial peak. We show that a shock-cooling model followed by a magnetar driving the second phase of the light curve can adequately explain the entire light curve of DES14X3taz. Models involving the shock-cooling of extended circumstellar material at a distance of ≃400 R ⊙ are preferred over the cooling of shock-heated surface layers of a stellar envelope. We compare DES14X3taz to the few double-peaked SLSN-I events in the literature. Although the rise times and characteristics of these initial peaks differ, there exists the tantalizing possibility that they can be explained by one physical interpretation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ricapito, I.; Calderoni, P.; Poitevin, Y.
2015-03-15
Tritium processing technologies of the two European Test Blanket Systems (TBS), HCLL (Helium Cooled Lithium Lead) and HCPB (Helium Cooled Pebble Bed), play an essential role in meeting the main objectives of the TBS experimental campaign in ITER. The compliancy with the ITER interface requirements, in terms of space availability, service fluids, limits on tritium release, constraints on maintenance, is driving the design of the TBS tritium processing systems. Other requirements come from the characteristics of the relevant test blanket module and the scientific programme that has to be developed and implemented. This paper identifies the main requirements for themore » design of the TBS tritium systems and equipment and, at the same time, provides an updated overview on the current design status, mainly focusing onto the tritium extractor from Pb-16Li and TBS tritium accountancy. Considerations are also given on the possible extrapolation to DEMO breeding blanket. (authors)« less
NASA Astrophysics Data System (ADS)
Tatsumoto, H.; Shirai, Y.; Shiotsu, M.; Hata, K.; Kobayashi, H.; Naruo, Y.; Inatani, Y.; Kato, T.; Futakawa, M.; Kinoshita, K.
2010-06-01
A thermal-hydraulics experimental system of liquid hydrogen was developed in order to investigate the forced flow heat transfer characteristics in the various cooling channels for wide ranges of subcoolings, flow velocities, and pressures up to supercritical. A main tank is connected to a sub tank through a hydrogen transfer line with a control valve. A channel heater is located at one end of the transfer line in the main tank. Forced flow through the channel is produced by adjusting the pressure difference between the tanks and the valve opening. The mass flow rate is measured from the weight change of the main tank. For the explosion protection, electrical equipments are covered with a nitrogen gas blanket layer and a remote control system was established. The first cryogenic performance tests confirmed that the experimental system had satisfied with the required performances. The forced convection heat transfer characteristics was successfully measured at the pressure of 0.7 MPa for various flow velocities.
PROBING TRAPPIST-1-LIKE SYSTEMS WITH K2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Demory, Brice-Olivier; Queloz, Didier; Gillen, Ed
2016-07-10
The search for small planets orbiting late M dwarfs holds the promise of detecting Earth-size planets for which their atmospheres could be characterized within the next decade. The recent discovery of TRAPPIST-1 entertains hope that these systems are common around hosts located at the bottom of the main sequence. In this Letter, we investigate the ability of the repurposed Kepler mission ( K2 ) to probe planetary systems similar to TRAPPIST-1. We perform a consistent data analysis of 189 spectroscopically confirmed M5.5 to M9 late M dwarfs from Campaigns 1–6 to search for planet candidates and inject transit signals withmore » properties matching TRAPPIST-1b and c. We find no transiting planet candidates across our K2 sample. Our injection tests show that K2 is able to recover both TRAPPIST-1 planets for 10% of the sample only, mainly because of the inefficient throughput at red wavelengths resulting in Poisson-limited performance for these targets. Increasing injected planetary radii to match GJ 1214b’s size yields a recovery rate of 70%. The strength of K2 is its ability to probe a large number of cool hosts across the different campaigns, out of which the recovery rate of 10% may turn into bona fide detections of TRAPPIST-1-like systems within the next two years.« less
Systems-Level Energy Audit for Main Complex, Construction Engineering Research Laboratory
2003-08-01
gas-fired boilers. Cooling is provided by two York electric chillers housed in the Utilities Building. Electric- ity and gas are metered by...small “instant recovery” electric water heater with a 20-gal size tank. Cooling In the spring of 1993, two R-22 (HCFC) York chiller units (rated at 180...tons each, but which can be peaked at 230 tons under favorable conditions) were in- stalled to replace the old chiller in the Utilities Building
Identification of parasitic losses in Yb:YLF and prospects for optical refrigeration down to 80K.
Melgaard, Seth; Seletskiy, Denis; Polyak, Victor; Asmerom, Yemane; Sheik-Bahae, Mansoor
2014-04-07
Systematic study of Yb doping concentration in the Yb:YLF cryocoolers by means of optical and mass spectroscopies has identified iron ions as the main source of the background absorption. Parasitic absorption was observed to decrease with Yb doping, resulting in optical cooling of a 10% Yb:YLF sample to 114K ± 1K, with room temperature cooling power of 750 mW and calculated minimum achievable temperature of 93 K.
A Possible Mechanism for Driving Oscillations in Hot Giant Planets
NASA Astrophysics Data System (ADS)
Dederick, Ethan; Jackiewicz, Jason
2017-03-01
The κ-mechanism has been successful in explaining the origin of observed oscillations of many types of “classical” pulsating variable stars. Here we examine quantitatively if that same process is prominent enough to excite the potential global oscillations within Jupiter, whose energy flux is powered by gravitational collapse rather than nuclear fusion. Additionally, we examine whether external radiative forcing, I.e., starlight, could be a driver for global oscillations in hot Jupiters orbiting various main-sequence stars at defined orbital semimajor axes. Using planetary models generated by the Modules for Experiments in Stellar Astrophysics and nonadiabatic oscillation calculations, we confirm that Jovian oscillations cannot be driven via the κ-mechanism. However, we do show that, in hot Jupiters, oscillations can likely be excited via the suppression of radiative cooling due to external radiation given a large enough stellar flux and the absence of a significant oscillatory damping zone within the planet. This trend does not seem to be dependent on the planetary mass. In future observations, we can thus expect that such planets may be pulsating, thereby giving greater insight into the internal structure of these bodies.
Climate model studies of synchronously rotating planets.
Joshi, Manoj
2003-01-01
M stars constitute 75% of main sequence stars though, until recently, their star systems have not been considered suitable places for habitable planets to exist. In this study the climate of a synchronously rotating planet around an M dwarf star is evaluated using a three-dimensional global atmospheric circulation model. The presence of clouds and evaporative cooling at the surface of the planet result in a cooler surface temperature at the subsolar point. Water ice forms at the polar regions and on the dark side, where the minimum temperature lies between -30 degrees C and 0 degrees C. As expected, rainfall is extremely high on the starlit side and extremely low on the dark side. The presence of a dry continent causes higher temperatures on the dayside, and allows accumulation of snow on the nightside. The absence of any oceans leads to higher day-night temperature differences, consistent with previous work. The present study reinforces recent conclusions that synchronously rotating planets within the circumstellar habitable zones of M dwarf stars should be habitable, and therefore M dwarf systems should not be excluded in future searches for exoplanets.
NASA Astrophysics Data System (ADS)
Tripathy, Haraprasanna; Subramanian, Raju; Hajra, Raj Narayan; Rai, Arun Kumar; Rengachari, Mythili; Saibaba, Saroja; Jayakumar, Tammana
2016-12-01
The sequence of phase instabilities that take place in a Fe-17.7Cr-9.3Ni-0.58Nb-2.95Cu-0.12N (wt pct) austenitic stainless steel (304H Cu grade) as a function of temperature has been investigated using dynamic calorimetry. The results obtained from this investigation are supplemented by Thermocalc-based equilibrium and Scheil-Gulliver nonequilibrium solidification simulation. The following phase transformation sequence is found upon slow cooling from liquid: L → L + γ → L + γ + MX → γ + MX + δ → γ +MX + M23C6 → γ + MX + M23C6 + Cu. Under slow cooling, the solidification follows austenite + ferrite (AF) mode, which is in accordance with Thermocalc prediction and Scheil-Gulliver simulation. However, higher cooling rates result in skeletal δ-ferrite formation, due to increased segregation tendency of Nb and Cr to segregate to interdendritic liquid. The solidification mode is found to depend on combined Nb + Cu content. Experimental estimates of enthalpy change associated with melting and secondary phase precipitation are also obtained. In addition a semi-quantitative study on the dissolution kinetics of M23C6 type carbides has also been investigated. The standard solution treatment at 1413 K (1140 °C) is found to be adequate to dissolve both Cu and M23C6 into γ-austenite; but the complete dissolution of MX type carbonitrides occurs near the melting region.
Towards the conceptual design of the cryogenic system of the Future Circular Collider (FCC)
NASA Astrophysics Data System (ADS)
Chorowski, M.; Correia Rodrigues, H.; Delikaris, D.; Duda, P.; Haberstroh, C.; Holdener, F.; Klöppel, S.; Kotnig, C.; Millet, F.; Polinski, J.; Quack, H.; Tavian, L.
2017-12-01
Following the update of the European strategy in particle physics, CERN has undertaken an international study of possible future circular colliders beyond the LHC. The study considers several options for very high-energy hadron-hadron, electron-positron and hadron-electron colliders. From the cryogenics point of view, the most challenging option is the hadron-hadron collider (FCC-hh) for which the conceptual design of the cryogenic system is progressing. The FCC-hh cryogenic system will have to produce up to 120 kW at 1.8 K for the superconducting magnet cooling, 6 MW between 40 and 60 K for the beam-screen and thermal-shield cooling as well as 850 g/s between 40 and 290 K for the HTS current-lead cooling. The corresponding total entropic load represents about 1 MW equivalent at 4.5 K and this cryogenic system will be by far the largest ever designed. In addition, the total mass to be cooled down is about 250’000 t and an innovative cool-down process must be proposed. This paper will present the proposed cryogenic layout and architecture, the cooling principles of the main components, the corresponding cooling schemes, as well as the cryogenic plant arrangement and proposed process cycles. The corresponding required development plan for such challenging cryogenic system will be highlighted.
The suitability of barium monofluoride for laser cooling from ab initio study
NASA Astrophysics Data System (ADS)
Kang, Shuying; Kuang, Fangguang; Jiang, Gang; Du, Jiguang
2016-03-01
The feasibility of laser cooling the 138Ba19F molecule is performed using ab initio quantum chemistry. Three low-lying doublet electronic states X 2Σ+, A' 2Δ and A 2Π are determined by the multireference configuration-interaction (MRCI) method, where the spin-orbit coupling (SOC) effect is also taken into account in the electronic structure calculations. The computed spectroscopic constants and permanent dipole moments agree well with the available experimental data. The Franck-Condon factors of the A 2П → X 2Σ+ transition show highly diagonal dominance (f00 = 0.981, f11 = 0.940, f22 = 0.896) and the A 2П state has a radiative lifetime of τ = 37.8 ns, allowing for rapid laser cooling. Our calculation indicates that the laser-cooling scheme require only three lasers at 822 nm, 855 nm and 856 nm proceeded on the A 2П (ν‧) ← X 2Σ+ (ν‧‧) transitions. The appeared intervening state A' 2Δ between the X 2Σ+ and A 2П states is the main challenge for laser cooling this molecule. In fact, the calculated vibrational branching loss ratio to the intermediate A' 2Δ state is almost negligible at a level of η < 4.5 × 10-9. Thus, BaF is a promising laser-cooling candidate with a relatively simple laser-cooling scheme.
Gamma prime precipitation modeling and strength responses in powder metallurgy superalloys
NASA Astrophysics Data System (ADS)
Mao, Jian
Precipitation-hardened nickel-based superalloys have been widely used as high temperature structural materials in gas turbine engine applications for more than 50 years. Powder metallurgy (P/M) technology was introduced as an innovative manufacturing process to overcome severe segregation and poor workability of alloys with high alloying contents. The excellent mechanical properties of P/M superalloys also depend upon the characteristic microstructures, including grain size and size distribution of gamma' precipitates. Heat treatment is the most critical processing step that has ultimate influences on the microstructure, and hence, on the mechanical properties of the materials. The main objective of this research was to study the gamma ' precipitation kinetics in various cooling circumstances and also study the strength response to the cooling history in two model alloys, Rne88DT and U720LI. The research is summarized below: (1) An experimental method was developed to allow accurate simulation and control of any desired cooling profile. Two novel cooling methods were introduced: continuous cooling and interrupt cooling. Isothermal aging was also carried out. (2) The growth and coarsening kinetics of the cooling gamma' precipitates were experimentally studied under different cooling and aging conditions, and the empirical equations were established. It was found that the cooling gamma' precipitate versus the cooling rate follows a power law. The gamma' precipitate size versus aging time obeys the LSW cube law for coarsening. (3) The strengthening of the material responses to the cooling rate and the decreasing temperature during cooling was investigated in both alloys. The tensile strength increases with the cooling rate. In addition, the non-monotonic response of strength versus interrupt temperature is of great interest. (4) An energy-driven model integrated with the classic growth and coarsen theories was successfully embedded in a computer program developed to simulate the cooling gamma ' precipitation based on the first principle of thermodynamics. The combination of the thermodynamic and the kinetic approaches provided a more practical method to determine the critical nucleation energy. (5) The simulation results proved the gamma' burst theory and the existence of the multi-stage burst of gamma' precipitates, which shows good agreement with the experimental data in a variety of aspects.
NASA Astrophysics Data System (ADS)
Różycka, Anna; Deptuch, Aleksandra; Jaworska-Gołąb, Teresa; Węgłowska, Dorota; Marzec, Monika
2018-02-01
Physical properties of a new ferroelectric liquid crystal have been studied by complementary methods: differential scanning calorimetry, polarizing optical microscopy, dielectric and X-ray diffraction. It was found that next to enantiotropic ferroelectric smectic C* phase, the monotropic smectic phase appears at cooling. X-ray diffraction measurements allowed to identify this phase as hexatic tilted smectic. Temperature dependence of spontaneous polarization, tilt angle of molecules and switching time were found in both liquid crystalline phases at cooling. Based on the dielectric results, the dielectric processes were identified as Goldstone mode in the smectic C* phase, whereas as the bond-orientation-like phason and the bulk domain mode in the monotropic hexatic tilted smectic phase.
Analysis of BF Hearth Reasonable Cooling System Based on the Water Dynamic Characteristics
NASA Astrophysics Data System (ADS)
Zuo, Haibin; Jiao, Kexin; Zhang, Jianliang; Li, Qian; Wang, Cui
A rational cooling water system is the assurance for long campaign life of blast furnace. In the paper, the heat transfer of different furnace period and different furnace condition based on the water quality characteristics were analysed, and the reason of the heat flux over the normal from the hydrodynamics was analysed. The results showed that, the vapour-film and scale existence significantly influenced the hearth heat transfer, which accelerated the brick lining erosion. The water dynamic characteristics of the parallel inner pipe or among the pipes were the main reason for the abnormal heat flux and film boiling. As to the reasonable cooling water flow, the gas film and the scale should be controlled and the energy saving should be considered.
ETR AND MTR COMPLEXES IN CONTEXT. CAMERA FACING NORTHERLY. FROM ...
ETR AND MTR COMPLEXES IN CONTEXT. CAMERA FACING NORTHERLY. FROM BOTTOM TO TOP: ETR COOLING TOWER, ELECTRICAL BUILDING AND LOW-BAY SECTION OF ETR BUILDING, HEAT EXCHANGER BUILDING (WITH U SHAPED YARD), COMPRESSOR BUILDING. MTR REACTOR SERVICES BUILDING IS ATTACHED TO SOUTH WALL OF MTR. WING A IS ATTACHED TO BALCONY FLOOR OF MTR. NEAR UPPER RIGHT CORNER OF VIEW IS MTR PROCESS WATER BUILDING. WING B IS AT FAR WEST END OF COMPLEX. NEAR MAIN GATE IS GAMMA FACILITY, WITH "COLD" BUILDINGS BEYOND: RAW WATER STORAGE TANKS, STEAM PLANT, MTR COOLING TOWER PUMP HOUSE AND COOLING TOWER. INL NEGATIVE NO. 56-4101. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Heat transfer and evaporative cooling in the function of pot-in-pot coolers
NASA Astrophysics Data System (ADS)
Chemin, Arsène; Levy Dit Vehel, Victor; Caussarieu, Aude; Plihon, Nicolas; Taberlet, Nicolas
2018-03-01
A pot-in-pot cooler is an affordable electricity-free refrigerator which uses the latent heat of vaporization of water to maintain a low temperature inside an inner compartment. In this article, we experimentally investigate the influence of the main physical parameters in model pot-in-pot coolers. The effect of the wind on the evaporation rate of the cooling fluid is studied in model experiments while the influence of the fluid properties (thermal conductivity, specific heat, and latent heat) is elucidated using a variety of cooling fluids (water, ethanol, and ether). A model based on a simplified heat conduction equation is proposed and is shown to be in good quantitative agreement with the experimental measurements.
NASA Astrophysics Data System (ADS)
Colleoni, Florence; Florindo, Fabio; McKay, Robert; Golledge, Nicholas; Sangiorgi, Francesca; Montoli, Enea; Masina, Simona; Cherchi, Annalisa; De Santis, Laura
2017-04-01
Sea Surface Temperatures (SST) reconstructions have shown that the Pliocene global zonal and meridional temperature gradients were different from today, implying changes of atmospheric and oceanic circulations, and thus of the main teleconnections. The impact of the main atmospheric teleconnections on the surface mass balance (SMB) of the Antarctic ice sheet (AIS) in the past has been seldom investigated. The ANDRILL marine record have shown that at the end of the Pliocene, the ice sheet expanded in the Ross Sea concomitantly with the expansion of the sea ice cover. This would have enhanced the formation of bottom waters that in turn, would have fostered upwelling along the West African coast and along the coast of Peru. The impact of Antarctica on the tropical climate dynamics has been shown by previous studies. To close the loop, this work investigates the impact of the tropical and high-latitude SST cooling on the main atmospheric teleconnections and then on the Antarctic SMB through the Plio/Pleistocene transition. Idealized Atmospheric General Circulation Model simulations are performed, in which high-latitude and tropical SST cooling are prescribed starting from the Pliocene SST. The atmospheric conditions obtained are then used to force an ice sheet model and a stand-alone energy balance model to investigate the impact on the SMB of the two main atmospheric teleconnections active in the Southern Hemisphere, namely the Southern Annular Mode (SAM) and the Pacific-South-American oscillation (PSA. In agreement with ANDRILL marine records, results show that the Easterlies strengthen along the Antarctic coasts during the Plio/Pleistocene transition. This, however, occurs only after cooling the tropical SSTs in the AGCM simulations. More importantly, the cooling of the tropical SST, through the strengthening of the PSA, has the largest influence on the spatial distribution of the climatic anomalies over Antarctica. This explains most of the SMB patterns simulated by the ice sheet model. In particular, the PSA fosters positive SMB over the Victoria Land, the Wilson Basin, the Aurora Basin and Prydz Bay that were partly deglaciated during the warm Pliocene. While the amplitude of the ice thickness changes due to the SAM and the PSA remains of the same order of today, i.e, few tens of meters, the main impact occurs in strategic areas of the AIS dynamics.
Planets, Planetary Nebulae, and Intermediate Luminosity Optical Transients (ILOTs)
NASA Astrophysics Data System (ADS)
Soker, Noam
2018-05-01
I review some aspects related to the influence of planets on the evolution of stars before and beyond the main sequence. Some processes include the tidal destruction of a planet on to a very young main sequence star, on to a low mass main sequence star, and on to a brown dwarf. This process releases gravitational energy that might be observed as a faint intermediate luminosity optical transient (ILOT) event. I then summarize the view that some elliptical planetary nebulae are shaped by planets. When the planet interacts with a low mass upper asymptotic giant branch (AGB) star it both enhances the mass loss rate and shapes the wind to form an elliptical planetary nebula, mainly by spinning up the envelope and by exciting waves in the envelope. If no interaction with a companion, stellar or sub-stellar, takes place beyond the main sequence, the star is termed a Jsolated star, and its mass loss rates on the giant branches are likely to be much lower than what is traditionally assumed.
Kiani, Hossein; Sun, Da-Wen; Zhang, Zhihang
2012-11-01
It has been proven that ultrasound irradiation can enhance the rate of heat transfer processes. The objective of this work was to study the heat transfer phenomenon, mainly the heat exchange at the surface, as affected by ultrasound irradiation around a stationary copper sphere (k=386W m(-1)K(-1), C(p)=384J kg(-1)K(-1), ρ=8660kg m(-3)) during cooling. The sphere (0.01m in diameter) was immersed in an ethylene glycol-water mixture (-10°C) in an ultrasonic cooling system that included a refrigerated circulator, a flow meter, an ultrasound generator and an ultrasonic bath. The temperature of the sphere was recorded using a data logger equipped with a T-type thermocouple in the center of the sphere. The temperature of the cooling medium was also monitored by four thermocouples situated at different places in the bath. The sphere was located at different positions (0.02, 0.04 and 0.06m) above the transducer surface of the bath calculated considering the center of the sphere as the center of the reference system and was exposed to different intensities of ultrasound (0, 120, 190, 450, 890, 1800, 2800, 3400 and 4100W m(-2)) during cooling. The frequency of the ultrasound was 25kHz. It was demonstrated that ultrasound irradiation can increase the rate of heat transfer significantly, resulting in considerably shorter cooling times. Higher intensities caused higher cooling rates, and Nu values were increased from about 23-27 to 25-108 depending on the intensity of ultrasound and the position of the sphere. However, high intensities of ultrasound led to the generation of heat at the surface of the sphere, thus limiting the lowest final temperature achieved. An analytical solution was developed considering the heat generation and was fitted to the experimental data with R(2) values in the range of 0.910-0.998. Visual observations revealed that both cavitation and acoustic streaming were important for heat transfer phenomenon. Cavitation clouds at the surface of the sphere were the main cause of heating effect. The results showed that closer distances to the transducer surface showed higher cooling rates. On the other hand, despite having a bigger distance from the transducer, when the sphere was located close to the gas-liquid interface the enhancement factor of heat transfer was higher. Ultrasound irradiation showed promising effect for the enhancement of convective heat transfer rate during immersion cooling. More investigations are required to demonstrate the behavior of ultrasound assisted heat transfer and resolve the proper way of the application of ultrasound to assist the cooling and/or freezing processes. Copyright © 2012 Elsevier B.V. All rights reserved.
Switching bonds in a DNA gel: an all-DNA vitrimer.
Romano, Flavio; Sciortino, Francesco
2015-02-20
We design an all-DNA system that behaves like vitrimers, innovative plastics with self-healing and stress-releasing properties. The DNA sequences are engineered to self-assemble first into tetra- and bifunctional units which, upon further cooling, bind to each other forming a fully bonded network gel. An innovative design of the binding regions of the DNA sequences, exploiting a double toehold-mediated strand displacement, generates a network gel which is able to reshuffle its bonds, retaining at all times full bonding. As in vitrimers, the rate of bond switching can be controlled via a thermally activated catalyst, which in the present design is very short DNA strands.
TIME-SERIES SPECTROSCOPY OF THE ECLIPSING BINARY Y CAM WITH A PULSATING COMPONENT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, Kyeongsoo; Lee, Jae Woo; Kim, Seung-Lee
We present the physical properties of the semi-detached Algol-type eclipsing binary Y Cam based on high resolution spectra obtained using the Bohyunsan Optical Echelle Spectrograph. This is the first spectroscopic monitoring data obtained for this interesting binary system, which has a δ Sct-type pulsating component. We obtained a total of 59 spectra over 14 nights from 2009 December to 2011 March. Double-lined spectral features from the hot primary and cool secondary components were well identified. We determined the effective temperatures of the two stars to be T{sub eff,1} = 8000 ± 250 K and T{sub eff,2} = 4629 ± 150more » K. The projected rotational velocities are v{sub 1}sin i{sub 1} = 51 ± 4 km s{sup −1} and v{sub 2}sin i{sub 2} = 50 ± 10 km s{sup −1}, which are very similar to a synchronous rotation with the orbital motion. Physical parameters of each component were derived by analyzing our radial velocity data together with previous photometric light curves from the literature. The masses and radii are M{sub 1} = 2.08 ± 0.09 M{sub ⊙}, M{sub 2} = 0.48 ± 0.03 M{sub ⊙}, R{sub 1} = 3.14 ± 0.05 R{sub ⊙}, and R{sub 2} = 3.33 ± 0.05 R{sub ⊙}, respectively. A comparison of these parameters with the theoretical evolution tracks showed that the primary component is located between the zero-age main sequence and the terminal-age main sequence, while the low-mass secondary is noticeably evolved. This indicates that the two components have experienced mass exchange with each other and the primary has undergone an evolution process different from that of single δ Sct-type pulsators.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hosokawa, Takashi; Offner, Stella S. R.; Krumholz, Mark R., E-mail: Takashi.Hosokawa@jpl.nasa.gov, E-mail: hosokwtk@gmail.com
2011-09-10
We revisit the problem of low-mass pre-main-sequence stellar evolution and its observational consequences for where stars fall on the Hertzsprung-Russell diagram (HRD). In contrast to most previous work, our models follow stars as they grow from small masses via accretion, and we perform a systematic study of how the stars' HRD evolution is influenced by their initial radius, by the radiative properties of the accretion flow, and by the accretion history, using both simple idealized accretion histories and histories taken from numerical simulations of star cluster formation. We compare our numerical results to both non-accreting isochrones and to the positionsmore » of observed stars in the HRD, with a goal of determining whether both the absolute ages and the age dispersions inferred from non-accreting isochrones are reliable. We show that non-accreting isochrones can sometimes overestimate stellar ages for more massive stars (those with effective temperatures above {approx}3500 K), thereby explaining why non-accreting isochrones often suggest a systematic age difference between more and less massive stars in the same cluster. However, we also find the only way to produce a similar overestimate for the ages of cooler stars is if these stars grow from {approx}0.01 M{sub sun} seed protostars that are an order of magnitude smaller than predicted by current theoretical models, and if the size of the seed protostar correlates systematically with the final stellar mass at the end of accretion. We therefore conclude that, unless both of these conditions are met, inferred ages and age spreads for cool stars are reliable, at least to the extent that the observed bolometric luminosities and temperatures are accurate. Finally, we note that the time dependence of the mass accretion rate has remarkably little effect on low-mass stars' evolution on the HRD, and that such time dependence may be neglected for all stars except those with effective temperatures above {approx}4000 K.« less
A generalized one-dimensional computer code for turbomachinery cooling passage flow calculations
NASA Technical Reports Server (NTRS)
Kumar, Ganesh N.; Roelke, Richard J.; Meitner, Peter L.
1989-01-01
A generalized one-dimensional computer code for analyzing the flow and heat transfer in the turbomachinery cooling passages was developed. This code is capable of handling rotating cooling passages with turbulators, 180 degree turns, pin fins, finned passages, by-pass flows, tip cap impingement flows, and flow branching. The code is an extension of a one-dimensional code developed by P. Meitner. In the subject code, correlations for both heat transfer coefficient and pressure loss computations were developed to model each of the above mentioned type of coolant passages. The code has the capability of independently computing the friction factor and heat transfer coefficient on each side of a rectangular passage. Either the mass flow at the inlet to the channel or the exit plane pressure can be specified. For a specified inlet total temperature, inlet total pressure, and exit static pressure, the code computers the flow rates through the main branch and the subbranches, flow through tip cap for impingement cooling, in addition to computing the coolant pressure, temperature, and heat transfer coefficient distribution in each coolant flow branch. Predictions from the subject code for both nonrotating and rotating passages agree well with experimental data. The code was used to analyze the cooling passage of a research cooled radial rotor.
On the non-existence of a sharp cooling break in gamma-ray burst afterglow spectra
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uhm, Z. Lucas; Zhang, Bing, E-mail: uhm@physics.unlv.edu, E-mail: zhang@physics.unlv.edu
Although the widely used analytical afterglow model of gamma-ray bursts (GRBs) predicts a sharp cooling break ν {sub c} in its afterglow spectrum, the GRB observations so far rarely show clear evidence for a cooling break in their spectra or a corresponding temporal break in their light curves. Employing a Lagrangian description of the blast wave, we conduct a sophisticated calculation of the afterglow emission. We precisely follow the cooling history of non-thermal electrons accelerated into each Lagrangian shell. We show that a detailed calculation of afterglow spectra does not in fact give rise to a sharp cooling break atmore » ν {sub c}. Instead, it displays a very mild and smooth transition, which occurs gradually over a few orders of magnitude in energy or frequency. The main source of this slow transition is that different mini shells have different evolutionary histories of the comoving magnetic field strength B, so that deriving the current value of ν {sub c} of each mini shell requires an integration of its cooling rate over the time elapsed since its creation. We present the time evolution of optical and X-ray spectral indices to demonstrate the slow transition of spectral regimes and discuss the implications of our result in interpreting GRB afterglow data.« less
Paleoclimatic analyses of middle Eocene through Oligocene planktic foraminiferal faunas
Keller, G.
1983-01-01
Quantitative faunal analyses and oxygen isotope ranking of individual planktic foraminiferal species from deep sea sequences of three oceans are used to make paleoceanographic and paleoclimatic inferences. Species grouped into surface, intermediate and deep water categories based on ??18O values provide evidence of major changes in water-mass stratification, and individual species abundances indicate low frequency cool-warm oscillations. These data suggest that relatively stable climatic phases with minor cool-warm oscillations of ???0.5 m.y. frequency are separated by rapid cooling events during middle Eocene to early Oligocene time. Five major climatic phases are evident in the water-mass stratification between middle Eocene through Oligocene time. Phase changes occur at P14/P15, P15/P16, P20/P21 and P21/P22 Zone boundaries and are marked by major faunal turnovers, rapid cooling in the isotope record, hiatuses and changes in the eustatic sea level. A general cooling trend between middle Eocene to early late Oligocene is indicated by the successive replacement of warm middle Eocene surface water species by cooler late Eocene intermediate water species and still cooler Oligocene intermediate and deep water species. Increased water-mass stratification in the latest Eocene (P17), indicated by the coexistence of surface, intermediate and deep dwelling species groups, suggest that increased thermal gradients developed between the equator and poles nearly coincident with the development of the psychrosphere. This pattern may be related to significant ice accumulation between late Eocene and early late Oligocene time. ?? 1983.
Groppe, Karoline; Elsner, Birgit
2015-04-01
Studies linking executive function (EF) and overweight suggest that a broad range of executive functions might influence weight via obesity-related behaviors, such as particular eating styles. Currently, however, longitudinal studies investigating this assumption in children are rare. We hypothesized that lower hot and cool EF predicts a stronger increase in eating styles related to greater weight gain (food approach) and a weaker increase in eating styles related to less weight gain (food avoidance) over a 1-year period. Hot (delay of gratification, affective decision-making) and cool (attention shifting, inhibition, working memory updating) EF was assessed experimentally in a sample of 1657 elementary-school children (German school classes 1-3) at two time points, approximately one year apart. The children's food-approach and food-avoidance behavior was rated mainly via parent questionnaires at both time points. As expected, lower levels of hot and cool EF predicted a stronger increase in several food-approach eating styles across a 1-year period, mainly in girls. Unexpectedly, poorer performance on the affective decision-making task also predicted an increase in certain food-avoidance styles, namely, slowness in eating and satiety responsiveness, in girls. Results implicate that lower EF is not only seen in eating-disordered or obese individuals but also acts as a risk factor for an increase in particular eating styles that play a role in the development of weight problems in children. Copyright © 2014 Elsevier Ltd. All rights reserved.
idRHa+ProMod - Rail Hardening Control System
NASA Astrophysics Data System (ADS)
Ferro, L.
2016-03-01
idRHa+ProMod is the process control system developed by Primetals Technologies to foresee the thermo-mechanical evolution and micro-structural composition of rail steels subjected to slack quenching into idRHa+ Rail Hardening equipments in a simulation environment. This tool can be used both off-line or in-line, giving the user the chance to test and study the best cooling strategies or letting the automatic control system free to adjust the proper cooling recipe. Optimization criteria have been tailored in order to determine the best cooling conditions according to the metallurgical requirements imposed by the main rail standards and also taking into account the elastoplastic bending phenomena occurring during all stages of the head hardening process. The computational core of idRHa+ProMod is a thermal finite element procedure coupled with special algorithms developed to work out the main thermo-physical properties of steel, to predict the non-isothermal austenite decomposition into all the relevant phases and subsequently to evaluate the amount of latent heat of transformation released, the compound thermal expansion coefficient and the amount of plastic deformation in the material. Air mist and air blades boundary conditions have been carefully investigated by means of pilot plant tests aimed to study the jet impingement on rail surfaces and the cooling efficiency at all working conditions. Heat transfer coefficients have been further checked and adjusted directly on field during commissioning. idRHa+ is a trademark of Primetals Technologies Italy Srl
NASA Astrophysics Data System (ADS)
Kashif, Ismail; Soliman, Ashia A.; Sakr, Elham M.; Ratep, Asmaa
2012-01-01
The glass system (45Li2O + 45B2O3 + 10Nb2O5) was fabricated by the conventional melt quenching technique poured in water, at air, between two hot plates and droplets at the cooled surface. The glass and glass ceramics were studied by differential thermal analysis (DTA) and X-ray diffraction (XRD). The as quenched samples poured in water and between two hot plates were amorphous. The samples poured at air and on cooled surface were crystalline as established via X-ray powder diffraction (XRD) studies. Differential thermal analysis was measured. The glass transition temperature (Tg) and the crystallization temperatures were calculated. Lithium niobate (LiNbO3) was the main phase in glass ceramic poured at air, droplets at the cooled surface and the heat treated glass sample at 500, 540 and 580 °C in addition to traces from LiNb3O8. Crystallite size of the main phases determined from the X-ray diffraction peaks is in the range of <100 nm. The fraction of crystalline (LiNbO3) phase decreases with increase in the heat treatment temperature.
Innovative discharge geometries for diffusion-cooled gas lasers
NASA Astrophysics Data System (ADS)
Lapucci, Antonio
2004-09-01
Large area, narrow discharge gap, diffusion cooled gas lasers are nowadays a well established technology for the construction of industrial laser sources. Successful examples exist both with the slab (Rofin-Sinar) or coaxial (Trumpf) geometry. The main physical properties and the associated technical problems of the transverse large area RF discharge, adopted for the excitation of high power diffusion cooled gas lasers, are reviewed here. The main problems of this technology are related to the maintenance of a uniform and stable plasma excitation between closely spaced large-area electrodes at high power-density loading. Some practical solutions such as distributed resonance of the discharge channel proved successful in the case of square or rectangular cross-sections but hardly applicable to geometries such as that of coaxial electrodes. In this paper we present some solutions, adopted by our group, for the development of slab and annular CO2 lasers and for CO2 laser arrays with linear or circular symmetry. We will also briefly mention the difficulties encountered in the extraction of a good quality beam from an active medium with such a cross section. A problem that has also seen some interesting solutions.
NASA Astrophysics Data System (ADS)
Woodward, C. A.; Shulmeister, J.
2007-01-01
We present chironomid-based temperature reconstructions from lake sediments deposited between ca 26,600 cal yr BP and 24,500 cal yr BP from Lyndon Stream, South Island, New Zealand. Summer (February mean) temperatures averaged 1 °C cooler, with a maximum inferred cooling of 3.7 °C. These estimates corroborate macrofossil and beetle-based temperature inferences from the same site and suggest climate amelioration (an interstadial) at this time. Other records from the New Zealand region also show a large degree of variability during the late Otiran glacial sequence (34,000-18,000 cal yr BP) including a phase of warming at the MIS 2/3 transition and a maximum cooling that did not occur until the global LGM (ca 20,000 cal yr BP). The very moderate cooling identified here at the MIS 2/3 transition confirms and enhances the long-standing discrepancy in New Zealand records between pollen and other proxies. Low abundances (<20%) of canopy tree pollen in records from late MIS 3 to the end of MIS 2 cannot be explained by the minor (<5 °C) cooling inferred from this and other studies unless other environmental parameters are considered. Further work is required to address this critical issue.
Modeling of steady-state convective cooling of cylindrical Li-ion cells
NASA Astrophysics Data System (ADS)
Shah, K.; Drake, S. J.; Wetz, D. A.; Ostanek, J. K.; Miller, S. P.; Heinzel, J. M.; Jain, A.
2014-07-01
While Lithium-ion batteries have the potential to serve as an excellent means of energy storage, they suffer from several operational safety concerns. Temperature excursion beyond a specified limit for a Lithium-ion battery triggers a sequence of decomposition and release, which can preclude thermal runaway events and catastrophic failure. To optimize liquid or air-based convective cooling approaches, it is important to accurately model the thermal response of Lithium-ion cells to convective cooling, particularly in high-rate discharge applications where significant heat generation is expected. This paper presents closed-form analytical solutions for the steady-state temperature profile in a convectively cooled cylindrical Lithium-ion cell. These models account for the strongly anisotropic thermal conductivity of cylindrical Lithium-ion batteries due to the spirally wound electrode assembly. Model results are in excellent agreement with experimentally measured temperature rise in a thermal test cell. Results indicate that improvements in radial thermal conductivity and axial convective heat transfer coefficient may result in significant peak temperature reduction. Battery sizing optimization using the analytical model is discussed, indicating the dependence of thermal performance of the cell on its size and aspect ratio. Results presented in this paper may aid in accurate thermal design and thermal management of Lithium-ion batteries.
A Compact, High-Performance Continuous Magnetic Refrigerator
NASA Technical Reports Server (NTRS)
Shirron, Peter; Canavan, Edgar; DiPirro, Michael; Jackson, Michael; King, Todd; Panek, John; Tuttle, James; Brodeur, Stephen J. (Technical Monitor)
2001-01-01
We present test results of the first adiabatic demagnetization refrigerator (ADR) that can produce continuous cooling at sub-kelvin temperatures. This system uses multiple stages that operate in sequence to cascade heat from a continuous stage up to a heat sink. Continuous operation aids the usual constraints of long hold times and short recycle times that lead to the generally large mass of single-shot ADRs, and allows us to achieve much higher cooling power per unit mass. Our design goal is 10 microW of cooling at 50 mK while rejecting heat to a 6-10 K heat sink. The total cold mass is estimated to be less than 10 kg, including magnetic shielding of each stage. These parameters envelop the requirements for currently planned astronomy missions. The relatively high heat rejection capability allows it to operate with a mechanical cryocooler as part of a cryogen-free, low temperature cooling system. This has the advantages of long, mission life and reduced complexity and cost. At present, we have assembled a three-stage ADR that operates with a superfluid helium bath. Additional work is underway to develop magnetocaloric materials that can extend its heat rejection capability up to 10 K. This paper discusses the design and operation of the ADR, as well as interface requirements for cryocooler-based operation.
Effects of some cryopreservation procedures on recalcitrant zygotic embryos of Ammocharis coranica.
Nomali, Z; Ngobese; Sershen; Berjak, P; Pammenter, N W
2014-01-01
Cryopreservation, the most promising method for the long-term conservation of recalcitrant (desiccation-sensitive) seed germplasm, is often associated with high viability losses. Cryo-procedures involve a sequence of steps which must be optimised to reduce the impact of the stresses. This study reports on the effects of some of the steps of cryopreservation on the recalcitrant zygotic embryos of the amaryllid, Ammocharis coranica. Embryos were subjected to cryoprotection with glycerol and/or DMSO, rapid (flash) drying, and rapid (>100 degree C s(-1)) or slow (1 degree C s(-1)) cooling. Rapid dehydration (from c. 2.7 to 0.9 g g(-1) over 60 min) and cooling had a detrimental effect on the viability of the embryos, which was exacerbated when these steps were applied sequentially. After cooling, seedling production (30%) was obtained only from embryos that had been cryoprotected with glycerol prior to drying and rapid cooling, while 30% of non-treated embryos and 70% of those that had undergone cathodic protection during flash drying produced callus. Noting that no post-cryo survival of A. coranica embryos had previously been obtained, this study identified cryoprotection with glycerol and the incorporation of cathodic protection during flash drying as promising intervention points for future studies.
Apparatus for cooling an electric machine
Palafox, Pepe; Gerstler, William Dwight; Shen, Xiaochun; El-Refaie, Ayman Mohamed Fawzi; Lokhandwalla, Murtuza; Salasoo, Lembit
2013-07-16
Provided is an apparatus, for example, for use with a rotating electric machine, that includes a housing. The housing can include a housing main portion and a housing end portion. The housing main portion can be configured to be disposed proximal to a body portion of a stator section of an electric machine. The housing main portion can define a main fluid channel that is configured to conduct fluid therethrough. The housing end portion can receive fluid from said main fluid channel and direct fluid into contact with a winding end portion of a conductive winding of the stator section.
Santos, M V; Sansinena, M; Zaritzky, N; Chirife, J
2012-01-01
In oocyte vitrification, plunging directly into liquid nitrogen favor film boiling and strong nitrogen vaporization. A survey of literature values of heat transfer coefficients (h) for film boiling of small metal objects with different geometries plunged in liquid nitrogen revealed values between 125 to 1000 W per per square m per K. These h values were used in a numerical simulation of cooling rates of two oocyte vitrification devices (open-pulled straw and Cryotop), plunged in liquid and slush nitrogen conditions. Heat conduction equation with convective boundary condition was considered a linear mathematical problem and was solved using the finite element method applying the variational formulation. COMSOL Multiphysics was used to simulate the cooling process of the systems. Predicted cooling rates for OPS and Cryotop when cooled at -196 degree C (liquid nitrogen) or -207 degree C (average for slush nitrogen) for heat transfer coefficients estimated to be representative of film boiling, indicated lowering the cooling temperature produces only a maximum 10 percent increase in cooling rates; confirming the main benefit of plunging in slush over liquid nitrogen does not arise from their temperature difference. Numerical simulations also demonstrated that a hypothetical four-fold increase in the cooling rate of vitrification devices when plunging in slush nitrogen would be explained by an increase in heat transfer coefficient. This improvement in heat transfer (i.e., high cooling rates) in slush nitrogen is attributed to less or null film boiling when a sample is placed in slush (mixture of liquid and solid nitrogen) because it first melts the solid nitrogen before causing the liquid to boil and form a film.
Buultjens, Andrew H.; Chua, Kyra Y. L.; Baines, Sarah L.; Kwong, Jason; Gao, Wei; Cutcher, Zoe; Adcock, Stuart; Ballard, Susan; Schultz, Mark B.; Tomita, Takehiro; Subasinghe, Nela; Carter, Glen P.; Pidot, Sacha J.; Franklin, Lucinda; Seemann, Torsten; Gonçalves Da Silva, Anders
2017-01-01
ABSTRACT Public health agencies are increasingly relying on genomics during Legionnaires' disease investigations. However, the causative bacterium (Legionella pneumophila) has an unusual population structure, with extreme temporal and spatial genome sequence conservation. Furthermore, Legionnaires' disease outbreaks can be caused by multiple L. pneumophila genotypes in a single source. These factors can confound cluster identification using standard phylogenomic methods. Here, we show that a statistical learning approach based on L. pneumophila core genome single nucleotide polymorphism (SNP) comparisons eliminates ambiguity for defining outbreak clusters and accurately predicts exposure sources for clinical cases. We illustrate the performance of our method by genome comparisons of 234 L. pneumophila isolates obtained from patients and cooling towers in Melbourne, Australia, between 1994 and 2014. This collection included one of the largest reported Legionnaires' disease outbreaks, which involved 125 cases at an aquarium. Using only sequence data from L. pneumophila cooling tower isolates and including all core genome variation, we built a multivariate model using discriminant analysis of principal components (DAPC) to find cooling tower-specific genomic signatures and then used it to predict the origin of clinical isolates. Model assignments were 93% congruent with epidemiological data, including the aquarium Legionnaires' disease outbreak and three other unrelated outbreak investigations. We applied the same approach to a recently described investigation of Legionnaires' disease within a UK hospital and observed a model predictive ability of 86%. We have developed a promising means to breach L. pneumophila genetic diversity extremes and provide objective source attribution data for outbreak investigations. IMPORTANCE Microbial outbreak investigations are moving to a paradigm where whole-genome sequencing and phylogenetic trees are used to support epidemiological investigations. It is critical that outbreak source predictions are accurate, particularly for pathogens, like Legionella pneumophila, which can spread widely and rapidly via cooling system aerosols, causing Legionnaires' disease. Here, by studying hundreds of Legionella pneumophila genomes collected over 21 years around a major Australian city, we uncovered limitations with the phylogenetic approach that could lead to a misidentification of outbreak sources. We implement instead a statistical learning technique that eliminates the ambiguity of inferring disease transmission from phylogenies. Our approach takes geolocation information and core genome variation from environmental L. pneumophila isolates to build statistical models that predict with high confidence the environmental source of clinical L. pneumophila during disease outbreaks. We show the versatility of the technique by applying it to unrelated Legionnaires' disease outbreaks in Australia and the UK. PMID:28821546
Analytical study of a microfludic DNA amplification chip using water cooling effect.
Chen, Jyh Jian; Shen, Chia Ming; Ko, Yu Wei
2013-04-01
A novel continuous-flow polymerase chain reaction (PCR) chip has been analyzed in our work. Two temperature zones are controlled by two external controllers and the other temperature zone at the chip center is controlled by the flow rate of the fluid inside a channel under the glass chip. By employing a water cooling channel at the chip center, the sequence of denaturation, annealing, and extension can be created due to the forced convection effect. The required annealing temperature of PCR less than 313 K can also be demonstrated in this chip. The Poly(methyl methacrylate) (PMMA) cooling channel with the thin aluminum cover is utilized to enhance the temperature uniformity. The size of this chip is 76 mm × 26 mm × 3 mm. This device represents the first demonstration of water cooling thermocycling within continuous-flow PCR microfluidics. The commercial software CFD-ACE+(TM) is utilized to determine the distances between the heating assemblies within the chip. We investigate the influences of various chip materials, operational parameters of the cooling channel and geometric parameters of the chip on the temperature uniformity on the chip surface. Concerning the temperature uniformity of the working zones and the lowest temperature at the annealing zone, the air gap spacing of 1 mm and the cooling channel thicknesses of 1 mm of the PMMA channel with an aluminum cover are recommended in our design. The hydrophobic surface of the PDMS channel was modified by filling it with 20 % Tween 20 solution and then adding bovine serum albumin (BSA) solution to the PCR mixture. DNA fragments with different lengths (372 bp and 478 bp) are successfully amplified with the device.
High Pressure Industrial Water Facility
NASA Technical Reports Server (NTRS)
1992-01-01
In conjunction with Space Shuttle Main Engine testing at Stennis, the Nordberg Water Pumps at the High Pressure Industrial Water Facility provide water for cooling the flame deflectors at the test stands during test firings.
NASA Astrophysics Data System (ADS)
Marzoli, A.; Davies, J.; Valeriani, L.; Preto, N.; Cirilli, S.; Panfili, G.; Dal Corso, J.; Vasconcellos, E.; Ernesto, M.; Youbi, N.; Callegaro, S.
2017-12-01
The end-Triassic global climate changes were probably triggered by the emplacement of the CAMP (Central Atlantic magmatic province). Here we explore the possibility that CAMP intrusions triggered global warming, while CAMP eruptions triggered short-lived cooling events. The main phase of the end-Triassic environmental changes and mass extinction was marked by two carbon isotopic excursions (CIEs). Based on stratigraphic and geochronologic data, we show that the earliest CAMP intrusions were emplaced at ca. 201.6 Ma prior to the first CIE (Davies et al., 2017). The main phase of CAMP magmatism started during the first CIE at ca. 201.5 Ma and continued until the second CIE and the Triassic-Jurassic boundary (at ca. 201.3 Ma). In particular, intrusion of the over 1 million cubic km of basaltic sills in Amazonia (Brazil) and of widespread sills from North America and Africa occurred within this interval. Multidisciplinary analyses show that organic matter rich sediments close to the sills from Brazil, Morocco, and the USA underwent contact metamorphism and organic carbon depletion. Such process may have released large amounts of thermogenic gases (CO2 and CH4) leading to global perturbation of the carbon cycle and to global warming. The timing of CAMP volcanic eruptions is well constrained by combined geochronologic, stratigraphic and palynologic data. In Morocco, newly observed palynological assemblages for sediments at the top of the lava piles are nearly identical to those found at the base of the volcanic sequences. These new data combined with carbon isotopic data indicate that over 95% of the CAMP lava flows in Morocco erupted during a short time interval at the very beginning of the end-Triassic extinction interval. A similar scenario applies possibly to the lava flows from North America. CAMP basalts are quite sulfur rich (up to 1800 ppm) suggesting that CAMP eruptions emitted large amounts of SO2. Such emissions lead possibly to short-lived cooling events. Davies J. et al. (2017). End-Triassic mass extinction started by intrusive CAMP activity. Nature Communications, doi: 10.1038/NCOMMS15596.
Recent advances in cooled-semen technology.
Aurich, Christine
2008-09-01
The majority of horse registries approve the use of artificial insemination, and horse breeding has widely taken benefit from the use of cooled-stored semen. New insights into cooled-semen technology open possibilities to reduce problems such as impaired semen quality after cooled-storage in individual stallions. The stallion itself has major impacts on quality and fertility of cooled-stored semen. Dietary supplementation of antioxidants and polyunsaturated fatty acids improves semen quality in a variety of species, but only few studies on this topic exist in the horse. Proper semen collection and handling is the main key to the maintenance of semen quality during cooled-storage. Semen collection should be achieved by minimal sexual stimulation with a single mount; this results in high sperm concentration, low content of seminal plasma and minimal contamination with bacteria. Milk-based semen extenders are most popular for semen processing and storage. The development of more defined extenders containing only the beneficial milk ingredients has made extender quality more constant and reliable. Semen is often centrifuged to decrease the seminal plasma content. Centrifugation results in a recovery rate of only 75% of spermatozoa in the semen pellet. Recovery rates after centrifugation may be improved with use of a "cushion technique" allowing higher centrifugation force and duration. However, this is not routinely used in cooled-semen technology. After slow-cooling, semen-storage and shipping is best performed at 5 degrees C, maintaining semen motility, membrane integrity and DNA integrity for up to 40 h after collection. Shipping containers created from Styrofoam boxes provide maintenance of semen quality at low cost.
An Aquifer Thermal Energy Storage (ATES) System for Continuous and Sustainable Cold Supply in Oman
NASA Astrophysics Data System (ADS)
Winterleitner, G.; Schütz, F.; Huenges, E.
2016-12-01
The aim of the GeoSolCool research programme between the German Research Centre for Geoscience (GFZ) and The Research Council of Oman (TRC) is the development of an innovative and sustainable cooling system in combination with an aquifer thermal energy storage system in northern Oman. An integral part of this project is the design of a subsurface aquifer reservoir system for storage of thermal energy through hot water injection. An accurate characterisation of potential storage horizons is thus essential to ensure optimal efficiency of the cooling system. The study area, 40 km west of Muscat is characterised by a thick Cenozoic mixed carbonate-siliciclastic sedimentary succession, containing at least 3 aquifer horizons. We used a multidisciplinary approach for the initial ATES development phase, including geological fieldwork dovetailed with remote sensing analyses, thin-section analyses, geological modelling and reservoir fluid flow forecasting. First results indicate two potential storage horizons: (1) a Miocene-aged clastic-dominated alluvial fan system and (2) an Eocene carbonate sequence. The alluvial fan system is a more than 300 m thick, coarse clastic (mainly gravels and sandstones) succession of coalesced individual fans. Thin-section analyses showed that hydraulic parameters are favourable for the gravel and sandstone intervals but reservoir architecture is complex due to multiple generations of interconnecting fans with highly heterogeneous facies distributions. The Eocene carbonates were deposited in a carbonate ramp setting, strongly influenced by currents and storm events. Individual facies belts extend over kilometres and thus horizontal reservoir connectivity is expected to be good with minor facies variability. Thin-section analyses showed that especially the fossil-rich sections show good storage qualities. Fluid flow forecasting indicate that both potential horizons have good to very good storage characteristics. However, intense diagenetic overprint of the succession and a complex reservoir architecture of the Miocene clastics might pose challenges for the ATES implementation. In order to decide which storage horizon will be developed as an ATES system, drilling of an exploration well and subsequent well-logging and hydraulic testing is underway.
Heavy nuclei as thermal insulation for protoneutron stars
NASA Astrophysics Data System (ADS)
Nakazato, Ken'ichiro; Suzuki, Hideyuki; Togashi, Hajime
2018-03-01
A protoneutron star (PNS) is a newly formed compact object in a core collapse supernova. In this paper, the neutrino emission from the cooling process of a PNS is investigated using two types of nuclear equation of state (EOS). It is found that the neutrino signal is mainly determined by the high-density EOS. The neutrino luminosity and mean energy are higher and the cooling time scale is longer for the softer EOS. Meanwhile, the neutrino mean energy and the cooling time scale are also affected by the low-density EOS because of the difference in the population of heavy nuclei. Heavy nuclei have a large scattering cross section with neutrinos owing to the coherent effects and act as thermal insulation near the surface of a PNS. The neutrino mean energy is higher and the cooling time scale is longer for an EOS with a large symmetry energy at low densities, namely a small density derivative coefficient of the symmetry energy, L .
Cooling Timescale of Dust Tori in Dying Active Galactic Nuclei
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ichikawa, Kohei; Tazaki, Ryo, E-mail: k.ichikawa@astro.columbia.edu
We estimate the dust torus cooling timescale once the active galactic nucleus (AGN) is quenched. In a clumpy torus system, once the incoming photons are suppressed, the cooling timescale of one clump from T {sub dust} = 1000 K to several 10 K is less than 10 years, indicating that the dust torus cooling time is mainly governed by the light crossing time of the torus from the central engine. After considering the light crossing time of the torus, the AGN torus emission at 12 μ m becomes over two orders of magnitude fainter within 100 years after the quenching.more » We also propose that those “dying” AGNs could be found using the AGN indicators with a different physical scale R such as 12 μ m band luminosity tracing AGN torus ( R ∼ 10 pc) and the optical [O iii] λ 5007 emission line tracing narrow line regions ( R = 10{sup 2–4} pc).« less
The Use of Infrared Thermography for Porosity Assessment of Intact Rock
NASA Astrophysics Data System (ADS)
Mineo, S.; Pappalardo, G.
2016-08-01
Preliminary results on a new test for the indirect assessment of porosity through infrared thermography are presented. The study of the cooling behavior of rock samples in laboratory, through the analysis of thermograms, proved an innovative tool for the estimation of such an important property, which is one of the main features affecting the mechanical behavior of rocks. A detailed experimentation was performed on artificially heated volcanic rock samples characterized by different porosity values. The cooling trend was described both graphically and numerically, with the help of cooling curves and Cooling Rate Index. The latter, which proved strictly linked to porosity, was employed to find reliable equations for its indirect estimation. Simple and multiple regression analyses returned satisfactory outcomes, highlighting the great match between predicted and measured porosity values, thus confirming the goodness of the proposed model. This study brings a novelty in rock mechanics, laying the foundation for future researches aimed at refining achieved results for the validation of the model in a larger scale.
Fournel, Sébastien; Ouellet, Véronique; Charbonneau, Édith
2017-05-02
Heat stress negatively affects the health and performance of dairy cows, resulting in considerable economic losses for the industry. In future years, climate change will exacerbate these losses by making the climate warmer. Physical modification of the environment is considered to be the primary means of reducing adverse effects of hot weather conditions. At present, to reduce stressful heat exposure and to cool cows, dairy farms rely on shade screens and various forms of forced convection and evaporative cooling that may include fans and misters, feed-line sprinklers, and tunnel- or cross-ventilated buildings. However, these systems have been mainly tested in subtropical areas and thus their efficiency in humid continental climates, such as in the province of Québec, Canada, is unclear. Therefore, this study reviewed the available cooling applications and assessed their potential for northern regions. Thermal stress indices such as the temperature-humidity index (THI) were used to evaluate the different cooling strategies.
Global thermal analysis of air-air cooled motor based on thermal network
NASA Astrophysics Data System (ADS)
Hu, Tian; Leng, Xue; Shen, Li; Liu, Haidong
2018-02-01
The air-air cooled motors with high efficiency, large starting torque, strong overload capacity, low noise, small vibration and other characteristics, are widely used in different department of national industry, but its cooling structure is complex, it requires the motor thermal management technology should be high. The thermal network method is a common method to calculate the temperature field of the motor, it has the advantages of small computation time and short time consuming, it can save a lot of time in the initial design phase of the motor. The domain analysis of air-air cooled motor and its cooler was based on thermal network method, the combined thermal network model was based, the main components of motor internal and external cooler temperature were calculated and analyzed, and the temperature rise test results were compared to verify the correctness of the combined thermal network model, the calculation method can satisfy the need of engineering design, and provide a reference for the initial and optimum design of the motor.
Numerical evaluation of single central jet for turbine disk cooling
NASA Astrophysics Data System (ADS)
Subbaraman, M. R.; Hadid, A. H.; McConnaughey, P. K.
The cooling arrangement of the Space Shuttle Main Engine High Pressure Oxidizer Turbopump (HPOTP) incorporates two jet rings, each of which produces 19 high-velocity coolant jets. At some operating conditions, the frequency of excitation associated with the 19 jets coincides with the natural frequency of the turbine blades, contributing to fatigue cracking of blade shanks. In this paper, an alternate turbine disk cooling arrangement, applicable to disk faces of zero hub radius, is evaluated, which consists of a single coolant jet impinging at the center of the turbine disk. Results of the CFD analysis show that replacing the jet ring with a single central coolant jet in the HPOTP leads to an acceptable thermal environment at the disk rim. Based on the predictions of flow and temperature fields for operating conditions, the single central jet cooling system was recommended for implementation into the development program of the Technology Test Bed Engine at NASA Marshall Space Flight Center.
Gomez-Smith, C Kimloi; LaPara, Timothy M; Hozalski, Raymond M
2015-07-21
The quantity and composition of bacterial biofilms growing on 10 water mains from a full-scale chloraminated water distribution system were analyzed using real-time PCR targeting the 16S rRNA gene and next-generation, high-throughput Illumina sequencing. Water mains with corrosion tubercles supported the greatest amount of bacterial biomass (n = 25; geometric mean = 2.5 × 10(7) copies cm(-2)), which was significantly higher (P = 0.04) than cement-lined cast-iron mains (n = 6; geometric mean = 2.0 × 10(6) copies cm(-2)). Despite spatial variation of community composition and bacterial abundance in water main biofilms, the communities on the interior main surfaces were surprisingly similar, containing a core group of operational taxonomic units (OTUs) assigned to only 17 different genera. Bacteria from the genus Mycobacterium dominated all communities at the main wall-bulk water interface (25-78% of the community), regardless of main age, estimated water age, main material, and the presence of corrosion products. Further sequencing of the mycobacterial heat shock protein gene (hsp65) provided species-level taxonomic resolution of mycobacteria. The two dominant Mycobacteria present, M. frederiksbergense (arithmetic mean = 85.7% of hsp65 sequences) and M. aurum (arithmetic mean = 6.5% of hsp65 sequences), are generally considered to be nonpathogenic. Two opportunistic pathogens, however, were detected at low numbers: M. hemophilum (arithmetic mean = 1.5% of hsp65 sequences) and M. abscessus (arithmetic mean = 0.006% of hsp65 sequences). Sulfate-reducing bacteria from the genus Desulfovibrio, which have been implicated in microbially influenced corrosion, dominated all communities located underneath corrosion tubercules (arithmetic mean = 67.5% of the community). This research provides novel insights into the quantity and composition of biofilms in full-scale drinking water distribution systems, which is critical for assessing the risks to public health and to the water supply infrastructure.
Note: control of liquid helium supply to cryopanels of Kolkata superconducting cyclotron.
Bhattacharyya, T K; Pal, G
2015-02-01
The Kolkata superconducting cyclotron utilises liquid helium to cool the main magnet niobium-titanium (NbTi) coil and the cryopanels. Three liquid helium cooled cryopanels, placed inside the dees of the radio-frequency system, maintain the high vacuum in the acceleration region of the superconducting cyclotron. The small cryostat placed inside the cryogenic distribution manifold located at the basement of the superconducting cyclotron building supplies liquid helium in parallel branches to three cold heads, used for cooling their associated cryopanels. The level in the cryostat has to be maintained at an optimum value to ensure uninterrupted flow of liquid helium to these three cold heads. This paper describes the transfer function of the overall system, its tuning parameters, and discusses the actual control of cryostat level by using these parameters.
Methane heat transfer investigation
NASA Technical Reports Server (NTRS)
1984-01-01
Future high chamber pressure LOX/hydrocarbon booster engines require copper base alloy main combustion chamber coolant channels similar to the SSME to provide adequate cooling and reusable engine life. Therefore, it is of vital importance to evaluate the heat transfer characteristics and coking thresholds for LNG (94% methane) cooling, with a copper base alloy material adjacent to he fuel coolant. High pressure methane cooling and coking characteristics recently evaluated at Rocketdyne using stainless steel heated tubes at methane bulk temperatures and coolant wall temperatures typical of advanced engine operation except at lower heat fluxes as limited by the tube material. As expected, there was no coking observed. However, coking evaluations need be conducted with a copper base surface exposed to the methane coolant at higher heat fluxes approaching those of future high chamber pressure engines.
NASA Astrophysics Data System (ADS)
Hofmeister, M.; Franke, M. M.; Koerner, C.; Singer, R. F.
2017-12-01
Superalloy gas turbine blades are being produced by investment casting and directional solidification. A new process, Fluidized Carbon Bed Cooling (FCBC), has been developed and is now being optimized in a prototype casting unit with 10 kg pouring weight. In early test runs with still rather simple mold cluster geometries, a reduction of the primary dendrite arm spacing of around 40 pct compared to the standard radiation cooling process (HRS) could be demonstrated. The improvement is mainly attributed to higher temperature gradients driving solidification, made possible by a functioning Dynamic Baffle. Compared to earlier development efforts in the literature, contamination of the melt and damage to the equipment are avoided using carbon-based fluidized bed materials and the so-called "counter pressure concept."
On-and-off chip cooling of a Coulomb blockade thermometer down to 2.8 mK
NASA Astrophysics Data System (ADS)
Palma, M.; Scheller, C. P.; Maradan, D.; Feshchenko, A. V.; Meschke, M.; Zumbühl, D. M.
2017-12-01
Cooling nanoelectronic devices below 10 mK is a great challenge since thermal conductivities become very small, thus creating a pronounced sensitivity to heat leaks. Here, we overcome these difficulties by using adiabatic demagnetization of both the electronic leads and the large metallic islands of a Coulomb blockade thermometer. This reduces the external heat leak through the leads and also provides on-chip refrigeration, together cooling the thermometer down to 2.8 ± 0.1 mK. We present a thermal model which gives a good qualitative account and suggests that the main limitation is heating due to pulse tube vibrations. With better decoupling, temperatures below 1 mK should be within reach, thus opening the door for μK nanoelectronics.
AK Sco: a tidally induced atmospheric dynamo in a pre-main sequence binary?
NASA Astrophysics Data System (ADS)
Gómez de Castro, A. I.
2009-02-01
AK Sco is a unique source: a 10-30 Myrs old pre-main sequence spectroscopic binary composed by two nearly equal F5 stars that at periastron are separated by barely eleven stellar radii so, the stellar magnetospheres fill the Roche lobe at periastron. The orbit is not yet circularized (e = 0.47) and very strong tides are expected. This makes of AK Sco, the ideal laboratory to study the effect of gravitational tides in the stellar magnetic field building up during pre-main sequence evolution. Evidence of this effect is reported in this contribution.
The Winds of Main Sequence B Stars in NGC 6231, Evidence for Shocks in Weak Winds.
NASA Astrophysics Data System (ADS)
Massa, Derck
1996-07-01
Because the main sequence B stars in NGC 6231 have abnormallystrong C iv wind lines, they are the only main sequence Bstars with distinct edge velocities. Although the underlyingcause for the strong lines remains unknown, these stars doprovide an opportunity to test two important ideas concerningB star winds: 1) that the driving ions in the winds of starswith low mass loss rates decouple from the general flow, and;2) that shocks deep in the winds of main sequence B stars areresponsible for their observed X-rays. In both of thesemodels, the wind accelerates toward a terminal velocity,v_infty, far greater than the observed value, shocking ordecoupling well before it can attain the high v_infty. As aresult, the observable wind accelerates very rapidly, leadingto wind flushing times less than 30 minutes. If theseconjectures are correct, then the winds of main sequence Bstars should be highly variable on time scales of minutes.Model fitting of available IUE data are consistant with thegeneral notion of a rapidly accelerating wind, shocking wellbefore its actual v_infty. However, these are 5 hourexposures, so the fits are to ill-defined mean wind flows.The new GHRS observations will provide adequate spectral andtemporal resolution to observe the expected variability and,thereby, verify the existance of two important astrophysicalprocesses.
Fournel, Sébastien; Ouellet, Véronique; Charbonneau, Édith
2017-01-01
Simple Summary The severity of heat stress issues on dairy cows will increase as global warming progresses. Fortunately, major advances in environmental management, including fans, misters, sprinklers, and cooled waterbeds, can attenuate the effects of thermal stress on cow health, production, and reproduction. These cooling systems were, however, tested in subtropical areas and their efficiency in northern regions is uncertain. This article assesses the potential of existing technologies to cool cows in humid continental climates through calculation of heat stress indices. Abstract Heat stress negatively affects the health and performance of dairy cows, resulting in considerable economic losses for the industry. In future years, climate change will exacerbate these losses by making the climate warmer. Physical modification of the environment is considered to be the primary means of reducing adverse effects of hot weather conditions. At present, to reduce stressful heat exposure and to cool cows, dairy farms rely on shade screens and various forms of forced convection and evaporative cooling that may include fans and misters, feed-line sprinklers, and tunnel- or cross-ventilated buildings. However, these systems have been mainly tested in subtropical areas and thus their efficiency in humid continental climates, such as in the province of Québec, Canada, is unclear. Therefore, this study reviewed the available cooling applications and assessed their potential for northern regions. Thermal stress indices such as the temperature-humidity index (THI) were used to evaluate the different cooling strategies. PMID:28468329
Response of upper ocean cooling off northeastern Taiwan to typhoon passages
NASA Astrophysics Data System (ADS)
Zheng, Zhe-Wen; Zheng, Quanan; Gopalakrishnan, Ganesh; Kuo, Yi-Chun; Yeh, Ting-Kuang
2017-07-01
A comprehensive investigation of the typhoon induced upper ocean processes and responses off northeastern Taiwan was conducted. Using the Regional Ocean Modeling System, the upper ocean responses of all typhoons striking Taiwan between 2005 and 2013 were simulated. In addition to Kuroshio intrusion, the present study demonstrates another important mechanism of typhoon induced near-inertial currents over the continental shelf of East China Sea, which can also trigger a distinct cooling (through entrainment mixing) within this region. Results indicate that the processes of typhoon inducing distinct cooling off northeastern Taiwan are conditional phenomena (only ∼12% of typhoons passing Taiwan triggered extreme cooling there). Subsequently, by executing a series of sensitivity experiments and systematic analyses on the behaviors and background conditions of all those typhoon cases, key criteria determining the occurrences of cooling through both mechanisms were elucidated. Occurrences of cooling through the Kuroshio intrusion mechanism are determined mainly by the strength of the local wind over northeastern Taiwan. A distinct cooling triggered by enhanced near-inertial currents is shown to be associated with the process of wind-current resonance. Both processes of Kuroshio intrusion and enhanced near-inertial currents are dominated by wind forcing rather than upper oceanic conditions. Based on the recent findings on the possible dynamic linkage between sea surface temperature near northeast Taiwan and local weather systems, the results elucidated in this study lay the foundation for further improvement in the regional weather prediction surrounding northeast Taiwan.
NASA Astrophysics Data System (ADS)
Pedersen, J. M.; Tegner, C.; Kent, A. J.; Ulrich, T.
2017-12-01
The opening of the North Atlantic Ocean between Greenland and Norway during the lower Tertiary led to intense flood basalt volcanism and the emplacement of the North Atlantic Igneous Province (NAIP). The volcanism is temporally overlapping with the Paleocene-Eocene Thermal Maximum (PETM), but ash stratigraphy and geochronology suggests that the main flood basalt sequence in East Greenland postdates the PETM. Significant environmental changes during the PETM have been attributed to the release of CO2 or methane gas due to either extensive melting of hydrates at the ocean floor or as a consequence of the interaction of mantle derived magmas with carbon rich sediments.Estimates suggest that a minimum of 1.8x106 km3 of basaltic lava erupted during North Atlantic flood basalt volcanism. Based on measurements of melt inclusions from the flood basalts our preliminary calculations suggest that approximately 2300 Gt of SO2 and 600 Gt of HCl were released into the atmosphere. Calculated yearly fluxes approach 23 Mt/y SO2 and 6 Mt/y HCl. These estimates are regarded as conservative.The S released into to the atmosphere during flood basalt volcanism can form acid aerosols that absorb and reflect solar radiation, causing an effective cooling effect. The climatic effects of the release of Cl into the atmosphere are not well constrained, but may be an important factor for extinction scenarios due to destruction of the ozone layer.The climatic changes due to the release of S and Cl in these amounts, and for periods extending for hundred thousand of years, although not yet fully constrained are likely to be significant. One consequence of the North Atlantic flood basalt volcanism may have been the initiation of global cooling to end the PETM.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kohutova, P.; Verwichte, E., E-mail: p.kohutova@warwick.ac.uk
Coronal rain composed of cool plasma condensations falling from coronal heights along magnetic field lines is a phenomenon occurring mainly in active region coronal loops. Recent high-resolution observations have shown that coronal rain is much more common than previously thought, suggesting its important role in the chromosphere-corona mass cycle. We present the analysis of MHD oscillations and kinematics of the coronal rain observed in chromospheric and transition region lines by the Interface Region Imaging Spectrograph (IRIS) , the Hinode Solar Optical Telescope (SOT), and the Solar Dynamics Observatory ( SDO) Atmospheric Imaging Assembly (AIA). Two different regimes of transverse oscillationsmore » traced by the rain are detected: small-scale persistent oscillations driven by a continuously operating process and localized large-scale oscillations excited by a transient mechanism. The plasma condensations are found to move with speeds ranging from few km s{sup −1} up to 180 km s{sup −1} and with accelerations largely below the free-fall rate, likely explained by pressure effects and the ponderomotive force resulting from the loop oscillations. The observed evolution of the emission in individual SDO /AIA bandpasses is found to exhibit clear signatures of a gradual cooling of the plasma at the loop top. We determine the temperature evolution of the coronal loop plasma using regularized inversion to recover the differential emission measure (DEM) and by forward modeling the emission intensities in the SDO /AIA bandpasses using a two-component synthetic DEM model. The inferred evolution of the temperature and density of the plasma near the apex is consistent with the limit cycle model and suggests the loop is going through a sequence of periodically repeating heating-condensation cycles.« less
Fundamental parameters of BE UMa revised
NASA Astrophysics Data System (ADS)
Shimanskii, V. V.; Borisov, N. V.; Pozdnyakova, S. A.; Bikmaev, I. F.; Vlasyuk, V. V.; Sakhibullin, N. A.; Spiridonova, O. I.
2008-07-01
We have determined a complete set of parameters for the young pre-cataclysmic variable BE UMa from a comprehensive photometric and spectroscopic analysis using model atmospheres. Our precise photometry and spectroscopy were acquired with the 6-m telescope and Zeiss-1000 telescope of the Special Astrophysical Observatory and the 1.5-m Russian-Turkish telescope at a wide range of orbital phases, including times of primary eclipses.We performed a detailed identification of emission lines of ten elements. At phases of minimum brightness, the spectra reveal absorption lines and molecular bands formed in the secondary’s atmosphere, whose effective temperature was determined to be T {/eff (2)} = 4750 ± 150 K. We have studied the radial-velocity curves of the cool star using lines of various elements. All the curves exhibit the previously predicted distortions due to reflection effects in the close binary. The derived component-mass ratio is q = 0.43 ± 0.09, and the component masses are M 1 = 0.59 ± 0.07 M ⊙ and M 2 = 0.25 ± 0.08 M ⊙. We analyzed the light curves using model atmospheres for irradiated stars; all the parameters of BE UMa were refined. We demonstrate the validity of our modeling of the binary’s spectra at phases of brightness maximum, which provides a good description of the observed intensities of most lines of heavy elements. The abundances of helium and several light elements (C, N, O, Ne, Mg) in the atmosphere of the cool star are probably higher than the solar values. We conclude that the physical characteristics of the primary are in good agreement with evolutionary tracks for planetary-nebula nuclei, and that the secondary is overluminous by a factor of 30 compared to main-sequence stars of the same mass.
Zhang, Jian-Kun; Wang, Zhen-Hua; Ye, Yun
2016-12-01
Three bacterial isolates, GT2, GT3, and GT7, were isolated from the sludge and water of a circulating cooling system of iron and steel plant by screening on Cr(VI)-containing plates. Three isolates were characterized as the members of the genus Pseudomonas on the basis of phenotypic characteristics and 16S rRNA sequence analysis. All isolates were capable of resisting multiple antibiotics and heavy metals. GT7 was most resistant to Cr(VI), with a minimum inhibitory concentration (MIC) of 6.5 mmol L -1 . GT7 displayed varied rates of Cr(VI) reduction in M2 broth, which was dependent on pH, initial Cr(VI) concentration, and inoculating dose. Total chromium analysis revealed that GT7 could remove a part of chromium from the media, and the maximum rate of chromium removal was up to 40.8 %. The Cr(VI) reductase activity of GT7 was mainly associated with the soluble fraction of cell-free extracts and reached optimum at pH 6.0∼8.0. The reductase activity was apparently enhanced by external electron donors and Cu(II), whereas it was seriously inhibited by Hg(II), Cd(II), and Zn(II). The reductase showed a K m of 74 μmol L -1 of Cr(VI) and a V max of 0.86 μmol of Cr(VI) min -1 mg -1 of protein. The results suggested that GT7 could be a promising candidate for in situ bioremediation of Cr(VI).
Electrophoretic mobility shift scanning using an automated infrared DNA sequencer.
Sano, M; Ohyama, A; Takase, K; Yamamoto, M; Machida, M
2001-11-01
Electrophoretic mobility shift assay (EMSA) is widely used in the study of sequence-specific DNA-binding proteins, including transcription factors and mismatch binding proteins. We have established a non-radioisotope-based protocol for EMSA that features an automated DNA sequencer with an infrared fluorescent dye (IRDye) detection unit. Our modification of the elec- trophoresis unit, which includes cooling the gel plates with a reduced well-to-read length, has made it possible to detect shifted bands within 1 h. Further, we have developed a rapid ligation-based method for generating IRDye-labeled probes with an approximately 60% cost reduction. This method has the advantages of real-time scanning, stability of labeled probes, and better safety associated with nonradioactive methods of detection. Analysis of a promoter from an industrially important filamentous fungus, Aspergillus oryzae, in a prototype experiment revealed that the method we describe has potential for use in systematic scanning and identification of the functionally important elements to which cellular factors bind in a sequence-specific manner.
Heat Recovery at Army Materiel Command (AMC) Facilities
1988-06-01
industrial complexes and somewhat smaller commercial/ HVAC ** systems, a portion of this waste heat can be recovered, improving energy efficiency. Heat...devices are used in sequence. Other shell-and-tube applications include heat transfer from process liquids, condensates, and cooling water. Two...pipe consists of a sealed element involving an annular capillary wick con- tained inside the full length of the tube, with an appropriate entrained
The Intelligent Management System: An Overview.
1982-12-07
comprises of hundreds of subprocesses concerned with bulb grasping, positioning, heating, cooling, etc. Each is sequentially related with others in time...activity. Activity schemata can be constructed into a network to define both parallel and sequential precedence, and hierarchical to describe...The flow of work is controlled by the "operation- lineup " associated with the product being manufactured. The operation- lineup specifies the sequence of
2015-07-16
0.02(λ/ n )3 modal volumes while preserving optical cavity Q up to5×106 [Fig. 4(f)-(i)]. The mechanical mode is modeled to have fundamental resonance Qm...addition, a 30.64-MHz resonance is observed and identified as one of the wineglass modes (circumferential number n = 4, “square” mode [40]) with a measured...main challenge is that mechanical resonators operating at high frequencies are extremely stiff, having spring constant on the order of 107 N /m. This
Flowing Air-Water Cooled Slab Nd: Glass Laser
NASA Astrophysics Data System (ADS)
Lu, Baida; Cai, Bangwei; Liao, Y.; Xu, Shifa; Xin, Z.
1989-03-01
A zig-zag optical path slab geometry Nd: glass laser cooled through flowing air-water is developed by us. Theoretical studies on temperature distribution of slab and rod configurations in the unsteady state clarify the advantages of the slab geometry laser. The slab design and processing are also reported. In our experiments main laser output characteristics, e. g. laser efficiency, polarization, far-field divergence angle as well as resonator misalignment are investigated. The slab phosphate glass laser in combination with a crossed Porro-prism resonator demonstrates a good laser performance.
Numerical Simulation of Film Cooling with a Coolant Supplied Through Holes in a Trench
NASA Astrophysics Data System (ADS)
Khalatov, A. A.; Panchenko, N. A.; Borisov, I. I.; Severina, V. V.
2017-05-01
The results of numerical simulation and experimental investigation of the efficiency of film cooling behind a row of holes in a trench in the range of blowing ratio variation 0.5 ≤ m ≤ 2.0 are presented. This scheme is of practical interest for use in the systems of cooling the blades of high-temperature gas turbines. Comparative analysis has shown that the efficiency of the trench scheme substantially exceeds the efficiency of the traditional scheme. The commercial package ANSYS CFX 14 was used in the Calculation Fluid Dynamics (CFD) modeling of film cooling. It is shown that the best agreement between predicted and experimental data is provided by the use of the SST model of turbulence. Analysis of the physical picture of flow has shown that the higher efficiency of film cooling with secondary air supply to the trench is mainly due to the preliminary spreading of a coolant in the trench, decrease in the intensity and scale of the vortex pair structure, absence of the coolant film departure from the plate surface, and to the more uniform transverse distribution of the coolant film.
Integration of active and passive cool roof system for attic temperature reduction
NASA Astrophysics Data System (ADS)
Yew, Ming Chian; Yew, Ming Kun; Saw, Lip Huat; Durairaj, Rajkumar
2017-04-01
The aim of this project is to study the capability of cool roof system in the reduction of heat transmission through metal roof into an attic. The cool roof system is designed in active and passive methods to reduce the thermal loads imposed to a building. Two main features are introduced to this cool roof system, which is thermal insulation coating (TIC) and moving air cavity (MAC) that served as active and passive manner, respectively. For MAC, two designs are introduced. Normal MAC is fabricated by six aluminium tubes whereby each aluminium tube is made up by sticking up of five aluminium cans. While improved MAC is also made by six aluminium tubes whereby each aluminium tube is custom made from steel rods and aluminium foils. MAC provides ventilation and heat reflection under the metal roof before the heat transfer into attic. It also coupled with three solar powered fans to increase heat flow inside the channel. The cool roof that incorporated TIC, MAC with solar powered fans and opened attic inlet showed a significant improvement with a reduction of up to 14 °C in the attic temperature compared to conventional roof system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, W., E-mail: luwang@impcas.ac.cn; University of Chinese Academy of Sciences, Beijing 100049; Xiong, B.
2014-02-15
A new room temperature ECR ion source, Lanzhou Electron Cyclotron Resonance ion source No. 4 (LECR4, previously named DRAGON), is under intense construction at Institute of Modern Physics. LECR4 is designed to operate with 18 GHz microwave frequency. The maximum axial magnetic fields are 2.3 T at injection and 1.3 T at extraction, and the radial field at the plasma chamber wall of 76 mm inner diameter is 1.0–1.2 T. One of the unique features for LECR4 is that its axial solenoids are winded with solid square copper wires which are immersed in a kind of special evaporative cooling mediummore » for cooling purpose. Till now, a prototype of the cooling system has been successfully constructed and tested, which has demonstrated that the cooling efficiency of the designed system could meet the requirements of LECR4 under the routine operation conditions. All the main components of the ion source have been completed. Assembly and commissioning is ongoing. The latest developments and test results will be presented in this paper.« less
Reducing Heat Gains and Cooling Loads Through Roof Structure Configurations of A House in Medan
NASA Astrophysics Data System (ADS)
Handayani Lubis, Irma; Donny Koerniawan, Mochamad
2018-05-01
Heat gains and heat losses through building surfaces are the main factors that determine the building’s cooling and heating loads. Roof as a building surface that has the most exposed area to the sun, contribute most of heat gains in the building. Therefore, the amount of solar heat gains on the roofs need to be minimized by roof structure configurations. This research aims to discover the optimization of roof structure configurations (coating material, structure material, inclination, overhang, and insulation) as one of passive design strategies that reduce heat gains and cooling loads of a house in Medan. The result showed that case four, white-painted metal roof combined with 45° roof pitched, 1.5m overhang, and addition of insulation, indicates the minimum heat gains production and the less cooling loads during clear sky day but not in the overcast sky condition. In conclusion, heat gains and cooling loads of a house in Medan could be diminished during clear sky day by the addition of roof coating with high reflectance low solar absorbtance, the slope roof, the extension of wider veranda, and the addition of insulation in the roof structure.
Regulation and Measurement of the Heat Generated by Automatic Tooth Preparation in a Confined Space.
Yuan, Fusong; Zheng, Jianqiao; Sun, Yuchun; Wang, Yong; Lyu, Peijun
2017-06-01
The aim of this study was to assess and regulate heat generation in the dental pulp cavity and circumambient temperature around a tooth during laser ablation with a femtosecond laser in a confined space. The automatic tooth preparing technique is one of the traditional oral clinical technology innovations. In this technique, a robot controlled an ultrashort pulse laser to automatically complete the three-dimensional teeth preparing in a confined space. The temperature control is the main measure for protecting the tooth nerve. Ten tooth specimens were irradiated with a femtosecond laser controlled by a robot in a confined space to generate 10 teeth preparation. During the process, four thermocouple sensors were used to record the pulp cavity and circumambient environment temperatures with or without air cooling. A statistical analysis of the temperatures was performed between the conditions with and without air cooling (p < 0.05). The recordings showed that the temperature with air cooling was lower than that without air cooling and that the heat generated in the pulp cavity was lower than the threshold for dental pulp damage. These results indicate that femtosecond laser ablation with air cooling might be an appropriate method for automatic tooth preparing.
Human heart conjugate cooling simulation: Unsteady thermo-fluid-stress analysis
Abdoli, Abas; Dulikravich, George S.; Bajaj, Chandrajit; Stowe, David F.; Jahania, M. Salik
2015-01-01
The main objective of this work was to demonstrate computationally that realistic human hearts can be cooled much faster by performing conjugate heat transfer consisting of pumping a cold liquid through the cardiac chambers and major veins while keeping the heart submerged in cold gelatin filling a cooling container. The human heart geometry used for simulations was obtained from three-dimensional, high resolution MRI scans. Two fluid flow domains for the right (pulmonic) and left (systemic) heart circulations, and two solid domains for the heart tissue and gelatin solution were defined for multi-domain numerical simulation. Detailed unsteady temperature fields within the heart tissue were calculated during the conjugate cooling process. A linear thermoelasticity analysis was performed to assess the stresses applied on the heart due to the coolant fluid shear and normal forces and to examine the thermal stress caused by temperature variation inside the heart. It was demonstrated that a conjugate cooling effort with coolant temperature at +4°C is capable of reducing the average heart temperature from +37°C to +8°C in 25 minutes for cases in which the coolant was steadily pumped only through major heart inlet veins and cavities. PMID:25045006
Sweat is a clear, salty liquid produced by glands in your skin. Sweating is how your body cools itself. You sweat mainly under your arms and on your feet and palms. When sweat mixes with bacteria on your skin, it can ...
NASA Technical Reports Server (NTRS)
Hintzen, Paul; Oswalt, Terry D.; Liebert, James; Sion, Edward M.
1989-01-01
During the course of a spectroscopic study of Luyten common proper motion (CPM) stars, spectrophotometric observations have been obtained of three binaries containing degenerate stars with estimated absolute magnitudes M(V) of about 16. Each of the three pairs consists of a yellow degenerate star primary and a DC 13 + secondary 1.4-2.3 mag fainter. One of the primary stars is spectral class DC 7, another is a sharp-lined DA 8, and the third shows peculiar broad absorption features which we interpret as pressure-shifted C2 Swan bands. The LP 701 - 69/70 system has survived for over 8 billion years without disruption by passing stars, despite its 1500 a.u. orbital major axis. The three cool degenerate companions nearly double the available sample of stars at the low-luminosity terminus of the white dwarf cooling sequence. These findings appear consistent with the conclusion that degenerate stars in the old disk population have not had time to evolve to a luminosity fainter than M(V) about 16.2.
NASA Astrophysics Data System (ADS)
Marx-Zimmer, M.; Herbstmeier, U.; Dickey, J. M.; Zimmer, F.; Staveley-Smith, L.; Mebold, U.
2000-02-01
The cool atomic interstellar medium of the Large Magellanic Cloud (LMC) seems to be quite different from that in the Milky Way. In a series of three papers we study the properties of the cool atomic hydrogen in the LMC (Paper I), its relation to molecular clouds using SEST-CO-observations (Paper II) and the cooling mechanism of the atomic gas based on ISO-[\\CII]-investigations (Paper III). In this paper we present the results of a third 21 cm absorption line survey toward the LMC carried out with the Australia Telescope Compact Array (ATCA). 20 compact continuum sources, which are mainly in the direction of the supergiant shell LMC 4, toward the surroundings of 30 Doradus and toward the eastern steep \\HI\\ boundary, have been chosen from the 1.4 GHz snapshot continuum survey of Marx et al. We have identified 20 absorption features toward nine of the 20 sources. The properties of the cool \\HI\\ clouds are investigated and are compared for the different regions of the LMC taking the results of Dickey et al. (survey 2) into account. We find that the cool \\HI\\ gas in the LMC is either unusually abundant compared to the cool atomic phase of the Milky Way or the gas is clearly colder (\\Tc\\ ~ 30 K) than that in our Galaxy (\\Tc\\ ~ 60 K). The properties of atomic clouds toward 30 Doradus and LMC 4 suggest a higher cooling rate in these regions compared to other parts of the LMC, probably due to an enhanced pressure near the shock fronts of LMC 4 and 30 Doradus. The detected cool atomic gas toward the eastern steep \\HI\\ boundary might be the result of a high compression of gas at the leading edge. The Australia Telescope is funded by the Commonwealth of Australia for operation as a National Facility managed by CSIRO.
Paleoenvironment of the Lowest Hominid-bearing Bed in the Sangiran Area, Indonesia
NASA Astrophysics Data System (ADS)
Kitaba, I.; Hyodo, M.; Matsu'ura, S.; Kondo, M.; Takeshita, Y.; Aziz, F.; Kumai, H.
2012-12-01
The first hominid migration out of Africa and dispersion to the eastern Asia are one of the main anthropological issues. However, we do not have consensus on their ages and pathway. The Sangiran area, Indonesia, has yielded more than 80 Homo erectus fossils. The mandibular bone, Pithecanthropus B (Sangiran 1b), has been found around the T11 volcanic ash layer in the upper part of the Sangiran Formation (the Lower Pleistocene). This specimen is one of the oldest Sangiran hominid fossils. Magnetostratigraphy shows that the T11 lies around the lower boundary of the Jaramillo subchronozone (1.07 Ma). We carried out pollen analysis of the sequence across T11 to reveal paleoenvironment when the possible first hominid arrival occurred in the Sangiran area, and discuss the causes of the emigration and settlement. In the layer from 1.0 m below to 0.5 m above T11, herbaceous taxa including Gramineae (> 50%) is dominant. They are accompanied by the aquatic taxa Typha and freshwater algae Pediastrum. The abundance of Gramineae shows dry environment. This sequence is also characterized by occurrences of Casuarinaga and Lagerstroemia, Salix, Corylus and Myrica, all living in dry lowlands. These features show that there was an open forest near freshwater. Around 0.5 m above T11, a big change in environment occurred. In the sequence above it, Gramineae (30-50%) decreased and Casuarinaga almost disappeared. Additionally, an increase in spores (10-40%) preferring a wet land shows an occurrence of wetting. At the same time, Manilkara (20-50%) increased sharply and became a main component of vegetation. The percentages of Psidium and Musa rose slightly. These taxa consist of many edible fruits. The lowland taxa like Lagerstroemia or Salix disappeared, which might show an occurrence of cooling. These environmental changes are consistent with the previous study based on diatom analysis. The result shows that around T11 there was a transgression, which may be correlated with marine oxygen isotope stage (MIS) 31. In summary, the early Indonesian hominids possibly migrated before the warm period of MIS 31. In a short time, the climate in this region became humid and they had plenty of edible fruits, which may have caused the settlement of the Sangiran hominids.
U-Pb Data On Apatites With Common Lead Correction : Exemples From The Scottish Caledonides
NASA Astrophysics Data System (ADS)
Jewison, E.; Deloule, E.; Villeneuve, J.; Bellahsen, N.; Labrousse, L.; Rosenberg, C.; Pik, R.; Chew, D.
2017-12-01
Apatite is a widely used mineral in low-temperature thermochronology (U-Th/He and AFT). The use of apatite in U-Pb geochronology has a great potential, given its closure temperature around 450°C, for orogen thermostructural evolution studies. However, since apatite can accumulate significant amount of initial Pb in its structure, its use can be hindered by the lack of 204 Pb estimations. To work around this, two options are commonly used : either use a ploting sytem that does not require corrected ratios, or use a proxy to estimate 204Pb and use it to correct the ratios. In this study we use a SIMS to mesure 204Pb in order to compare Tera-Wasserburg diagram and corrected ages to examine the cooling pattern in the northern Highlands of Scotland. The Highlands is an extensively studied caledonian collision wedge which results from the closure of the Iapétus Ocean during the Orodivician-Silurian. Two orogenic events are related to this closing, the grampian event (480-460Ma) and the scandian event (435-415 Ma) that culminated in the stacking of major ductile thrusts. The thermal history of thoses nappes are hence complex and the cooling pattern poorly constrained. Corrected apatite U-Pb ages provide new constrains on ductile wedge building and improve our understanding of mid to lower-crustal deformation and orogenic exhumation. Thoses corrected ages yield equivalent errors and mean ages from the classic method. Those data suggest a global cooling younger than previously thought and a sequence departing from a simple forward sequence. We thus present a refined thermal evolution and conceptualize a model of ductile wedge evolution.
Origin of ultramafic xenoliths containing exsolved pyroxenes from Hualalai Volcano, Hawaii
Bohrson, W.A.; Clague, D.A.
1988-01-01
Hualalai Volcano, Hawaii, is best known for the abundant and varied xenoliths included in the historic 1800 Kaupulehu alkalic basalt flow. Xenoliths, which range in composition from dunite to anorthosite, are concentrated at 915-m elevation in the flow. Rare cumulate ultramafic xenoliths, which include websterite, olivine websterite, wehrlite, and clinopyroxenite, display complex pyroxene exsolution textures that indicate slow cooling. Websterite, olivine websterite, and one wehrlite are spinel-bearing orthopyroxene +olivine cumulates with intercumulus clinopyroxene +plagioclase. Two wehrlite samples and clinopyroxenite are spinel-bearing olivine cumulates with intercumulus clinopyroxene+orthopyroxene + plagioclase. Two-pyroxene geothermometry calculations, based on reconstructed pyroxene compositions, indicate that crystallization temperatures range from 1225?? to 1350?? C. Migration or unmixing of clinopyroxene and orthopyroxene stopped between 1045?? and 1090?? C. Comparisons of the abundance of K2O in plagioclase and the abundances of TiO2 and Fe2O3in spinel of xenoliths and mid-ocean ridge basalt, and a single 87Sr/ 86Sr determination, indicate that these Hualalai xenoliths are unrelated to mid-ocean ridge basalt. Similarity between the crystallization sequence of these xenoliths and the experimental crystallization sequence of a Hawaiian olivine tholeiite suggest that the parental magma of the xenoliths is Hualalai tholeiitic basalt. Xenoliths probably crystallized between about 4.5 and 9 kb. The 155??-230?? C of cooling which took place over about 120 ka - the age of the youngest Hualalai tholeiitic basalt - yield maximum cooling rates of 1.3??10-3-1.91??10-3 ??C/yr. Hualalai ultramafic xenoliths with exsolved pyroxenes crystallized from Hualalai tholeiitic basalt and accumulated in a magma reservoir located between 13 and 28 km below sealevel. We suspect that this reservoir occurs just below the base of the oceanic crust at about 19 km below sealevel. ?? 1988 Springer-Verlag.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davidge, T. J.
2012-12-20
The stellar contents of the open clusters King 12, NGC 7788, and NGC 7790 are investigated using MegaCam images. Comparisons with isochrones yield an age <20 Myr for King 12, 20-40 Myr for NGC 7788, and 60-80 Myr for NGC 7790 based on the properties of stars near the main-sequence turnoff (MSTO) in each cluster. The reddening of NGC 7788 is much larger than previously estimated. The luminosity functions (LFs) of King 12 and NGC 7788 show breaks that are attributed to the onset of pre-main-sequence (PMS) objects, and comparisons with models of PMS evolution yield ages that are consistentmore » with those measured from stars near the MSTO. In contrast, the r' LF of main-sequence stars in NGC 7790 is matched to r' = 20 by a model that is based on the solar neighborhood mass function. The structural properties of all three clusters are investigated by examining the two-point angular correlation function of blue main-sequence stars. King 12 and NGC 7788 are each surrounded by a stellar halo that extends out to a radius of 5 arcmin ({approx}3.4 pc). It is suggested that these halos form in response to large-scale mass ejection early in the evolution of the clusters, as predicted by models. In contrast, blue main-sequence stars in NGC 7790 are traced out to a radius of {approx}7.5 arcmin ({approx}5.5 pc), with no evidence of a halo. It is suggested that all three clusters may have originated in the same star-forming complex, but not in the same giant molecular cloud.« less
Pre-main-sequence isochrones - II. Revising star and planet formation time-scales
NASA Astrophysics Data System (ADS)
Bell, Cameron P. M.; Naylor, Tim; Mayne, N. J.; Jeffries, R. D.; Littlefair, S. P.
2013-09-01
We have derived ages for 13 young (<30 Myr) star-forming regions and find that they are up to a factor of 2 older than the ages typically adopted in the literature. This result has wide-ranging implications, including that circumstellar discs survive longer (≃ 10-12 Myr) and that the average Class I lifetime is greater (≃1 Myr) than currently believed. For each star-forming region, we derived two ages from colour-magnitude diagrams. First, we fitted models of the evolution between the zero-age main sequence and terminal-age main sequence to derive a homogeneous set of main-sequence ages, distances and reddenings with statistically meaningful uncertainties. Our second age for each star-forming region was derived by fitting pre-main-sequence stars to new semi-empirical model isochrones. For the first time (for a set of clusters younger than 50 Myr), we find broad agreement between these two ages, and since these are derived from two distinct mass regimes that rely on different aspects of stellar physics, it gives us confidence in the new age scale. This agreement is largely due to our adoption of empirical colour-Teff relations and bolometric corrections for pre-main-sequence stars cooler than 4000 K. The revised ages for the star-forming regions in our sample are: ˜2 Myr for NGC 6611 (Eagle Nebula; M 16), IC 5146 (Cocoon Nebula), NGC 6530 (Lagoon Nebula; M 8) and NGC 2244 (Rosette Nebula); ˜6 Myr for σ Ori, Cep OB3b and IC 348; ≃10 Myr for λ Ori (Collinder 69); ≃11 Myr for NGC 2169; ≃12 Myr for NGC 2362; ≃13 Myr for NGC 7160; ≃14 Myr for χ Per (NGC 884); and ≃20 Myr for NGC 1960 (M 36).
NASA Technical Reports Server (NTRS)
Schreiber, Will
1986-01-01
Two sets of ball bearings support the main shaft within the High Pressure Oxygen Turbopump (HPOTP) in the Space Shuttle Main Engine (SSME). In operation, these bearings are cooled and lubricated with high pressure liquid oxygen (LOX) flowing axially through the bearing assembly. Currently, modifications in the assembly design are being contemplated in order to enhance the lifetime of the bearings and to allow the HPOTP to operate under larger loads. An understanding of the fluid dynamics and heat transfer characteristics of the flowing LOX is necessary for the implementation of these design changes. The proposed computational model of the LOX fluid dynamics, in addition to dealing with a turbulent flow in a complex geometry, must address the complication associated with boiling and two-phase flow. The feasibility of and possible methods for modeling boiling heat transfer are considered. The theory of boiling as pertains to this particular problem is reviewed. Recommendations are given for experiments which would be necessary to establish validity for correlations needed to model boiling.
Structural Design and Thermal Analysis for Thermal Shields of the MICE Coupling Magnets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Green, Michael A.; Pan, Heng; Liu, X. K.
2009-07-01
A superconducting coupling magnet made from copper matrix NbTi conductors operating at 4 K will be used in the Muon Ionization Cooling Experiment (MICE) to produce up to 2.6 T on the magnet centerline to keep the muon beam within the thin RF cavity indows. The coupling magnet is to be cooled by two cryocoolers with a total cooling capacity of 3 W at 4.2 K. In order to keep a certain operating temperature margin, the most important is to reduce the heat leakage imposed on cold surfaces of coil cold mass assembly. An ntermediate temperature shield system placed betweenmore » the coupling coil and warm vacuum chamber is adopted. The shield system consists of upper neck shield, main shields, flexible connections and eight supports, which is to be cooled by the first stage cold heads of two ryocoolers with cooling capacity of 55 W at 60 K each. The maximum temperature difference on the shields should be less than 20 K, so the thermal analyses for the shields with different thicknesses, materials, flexible connections for shields' cooling and structure design for heir supports were carried out. 1100 Al is finally adopted and the maximum temperature difference is around 15 K with 4 mm shield thickness. The paper is to present detailed analyses on the shield system design.« less
Sansinena, M; Santos, M V; Zaritzky, N; Chirife, J
2012-05-01
Slush nitrogen (SN(2)) is a mixture of solid nitrogen and liquid nitrogen, with an average temperature of -207 °C. To investigate whether plunging a French plastic straw (commonly used for sperm cryopreservation) in SN(2) substantially increases cooling rates with respect to liquid nitrogen (LN(2)), a numerical simulation of the heat conduction equation with convective boundary condition was used to predict cooling rates. Calculations performed using heat transfer coefficients in the range of film boiling confirmed the main benefit of plunging a straw in slush over LN(2) did not arise from their temperature difference (-207 vs. -196 °C), but rather from an increase in the external heat transfer coefficient. Numerical simulations using high heat transfer (h) coefficients (assumed to prevail in SN(2)) suggested that plunging in SN(2) would increase cooling rates of French straw. This increase of cooling rates was attributed to a less or null film boiling responsible for low heat transfer coefficients in liquid nitrogen when the straw is placed in the solid-liquid mixture or slush. In addition, predicted cooling rates of French straws in SN(2) tended to level-off for high h values, suggesting heat transfer was dictated by heat conduction within the liquid filled plastic straw. Copyright © 2012 Elsevier Inc. All rights reserved.
W134: A new pre-main-sequence double-lined spectroscopic binary
NASA Technical Reports Server (NTRS)
Padgett, Deborah L.; Stapelfeldt, Karl R.
1994-01-01
We report the discovery that the pre-main-sequence star Walker 134 in the young cluster NGC 2264 is a double-lined spectroscopic binary. Both components are G stars with strong Li I 6708 A absorption lines. Twenty radial velocity measurements have been used to determined the orbital elements of this system. The orbit has a period of 6.3532 +/- 0.0012 days and is circular within the limits of our velocity resolution; e less than 0.01. The total system mass is stellar mass sin(exp 3) i = 3.16 solar mass with a mass ratio of 1.04. Estimates for the orbit inclination angle and stellar radii place the system near the threshold for eclipse observability; howerver, no decrease in brightness was seen during two attempts at photometric monitoring. The circular orbit of W 134 fills an important gap in the period distribution of pre-main-sequence binaries and thereby constrains the effectiveness of tidal orbital circularization during the pre-main sequence.
A DYNAMICAL SIGNATURE OF MULTIPLE STELLAR POPULATIONS IN 47 TUCANAE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richer, Harvey B.; Heyl, Jeremy; Anderson, Jay
2013-07-01
Based on the width of its main sequence, and an actual observed split when viewed through particular filters, it is widely accepted that 47 Tucanae contains multiple stellar populations. In this contribution, we divide the main sequence of 47 Tuc into four color groups, which presumably represent stars of various chemical compositions. The kinematic properties of each of these groups are explored via proper motions, and a strong signal emerges of differing proper-motion anisotropies with differing main-sequence color; the bluest main-sequence stars exhibit the largest proper-motion anisotropy which becomes undetectable for the reddest stars. In addition, the bluest stars aremore » also the most centrally concentrated. A similar analysis for Small Magellanic Cloud stars, which are located in the background of 47 Tuc on our frames, yields none of the anisotropy exhibited by the 47 Tuc stars. We discuss implications of these results for possible formation scenarios of the various populations.« less
McGarr, Arthur F.; Barbour, Andrew
2017-01-01
Each of the three earthquake sequences in Oklahoma in 2016—Fairview, Pawnee, and Cushing—appears to have been induced by high-volume wastewater disposal within 10 km. The Fairview M5.1 main shock was part of a 2 year sequence of more than 150 events of M3, or greater; the main shock accounted for about half of the total moment. The foreshocks and aftershocks of the M5.8 Pawnee earthquake were too small and too few to contribute significantly to the cumulative moment; instead, nearly all of the moment induced by wastewater injection was focused on the main shock. The M5.0 Cushing event is part of a sequence that includes 48 earthquakes of M3, or greater, that are mostly foreshocks. The cumulative moment for each of the three sequences during 2016, as well as that for the 2011 Prague, Oklahoma, and nine other sequences representing a broad range of injected volume, are all limited by the total volumes of wastewater injected locally.
Dai, Steve Xunhu; Rodriguez, Mark A.; Griego, James M.
2016-06-01
Here, the sequence of crystallization in a re-crystallizable lithium silicate sealing glass-ceramic Li 2O-SiO 2-Al 2O 3-K 2O-B 2O 3-P 2O 5-ZnO was analyzed by in situ high temperature X-ray diffraction (HTXRD). Glass-ceramic specimens have been subjected to a 2-stage heat treatment schedule, including rapid cooling from sealing temperature to a 1st hold temperature 650 °C, following by heating to a 2nd hold temperature of 810 °C. Notable growth and saturation of Quartz was observed at 650 °C (1st hold).
The heat removal capability of actively cooled plasma-facing components for the ITER divertor
NASA Astrophysics Data System (ADS)
Missirlian, M.; Richou, M.; Riccardi, B.; Gavila, P.; Loarer, T.; Constans, S.
2011-12-01
Non-destructive examination followed by high-heat-flux testing was performed for different small- and medium-scale mock-ups; this included the most recent developments related to actively cooled tungsten (W) or carbon fibre composite (CFC) armoured plasma-facing components. In particular, the heat-removal capability of these mock-ups manufactured by European companies with all the main features of the ITER divertor design was investigated both after manufacturing and after thermal cycling up to 20 MW m-2. Compliance with ITER requirements was explored in terms of bonding quality, heat flux performances and operational compatibility. The main results show an overall good heat-removal capability after the manufacturing process independent of the armour-to-heat sink bonding technology and promising behaviour with respect to thermal fatigue lifetime under heat flux up to 20 MW m-2 for the CFC-armoured tiles and 15 MW m-2 for the W-armoured tiles, respectively.
Kono, H; Saven, J G
2001-02-23
Combinatorial experiments provide new ways to probe the determinants of protein folding and to identify novel folding amino acid sequences. These types of experiments, however, are complicated both by enormous conformational complexity and by large numbers of possible sequences. Therefore, a quantitative computational theory would be helpful in designing and interpreting these types of experiment. Here, we present and apply a statistically based, computational approach for identifying the properties of sequences compatible with a given main-chain structure. Protein side-chain conformations are included in an atom-based fashion. Calculations are performed for a variety of similar backbone structures to identify sequence properties that are robust with respect to minor changes in main-chain structure. Rather than specific sequences, the method yields the likelihood of each of the amino acids at preselected positions in a given protein structure. The theory may be used to quantify the characteristics of sequence space for a chosen structure without explicitly tabulating sequences. To account for hydrophobic effects, we introduce an environmental energy that it is consistent with other simple hydrophobicity scales and show that it is effective for side-chain modeling. We apply the method to calculate the identity probabilities of selected positions of the immunoglobulin light chain-binding domain of protein L, for which many variant folding sequences are available. The calculations compare favorably with the experimentally observed identity probabilities.
NASA Astrophysics Data System (ADS)
Shu, Gequn; Pan, Jiaying; Wei, Haiqiao; Shi, Ning
2013-03-01
Knock in spark-ignition(SI) engines severely limits engine performance and thermal efficiency. The researches on knock of downsized SI engine have mainly focused on structural design, performance optimization and advanced combustion modes, however there is little for simulation study on the effect of cooled exhaust gas recirculation(EGR) combined with downsizing technologies on SI engine performance. On the basis of mean pressure and oscillating pressure during combustion process, the effect of different levels of cooled EGR ratio, supercharging and compression ratio on engine dynamic and knock characteristic is researched with three-dimensional KIVA-3V program coupled with pressure wave equation. The cylinder pressure, combustion temperature, ignition delay timing, combustion duration, maximum mean pressure, and maximum oscillating pressure at different initial conditions are discussed and analyzed to investigate potential approaches to inhibiting engine knock while improving power output. The calculation results of the effect of just cooled EGR on knock characteristic show that appropriate levels of cooled EGR ratio can effectively suppress cylinder high-frequency pressure oscillations without obvious decrease in mean pressure. Analysis of the synergistic effect of cooled EGR, supercharging and compression ratio on knock characteristic indicates that under the condition of high supercharging and compression ratio, several times more cooled EGR ratio than that under the original condition is necessarily utilized to suppress knock occurrence effectively. The proposed method of synergistic effect of cooled EGR and downsizing technologies on knock characteristic, analyzed from the aspects of mean pressure and oscillating pressure, is an effective way to study downsized SI engine knock and provides knock inhibition approaches in practical engineering.
Cooling-induced contraction in ovine airways smooth muscle.
Mustafa, S M; Pilcher, C W; Williams, K I
1999-02-01
The mechanism of cold-induced bronchoconstriction is poorly understood. This prompted the present study whose aim was to determine the step-wise direct effect of cooling on smooth muscle of isolated ovine airways and analyse the role of calcium in the mechanisms involved. Isolated tracheal strips and bronchial segments were suspended in organ baths containing Krebs' solution for isometric tension recording. Tissue responses during stepwise cooling from 37 to 5 degrees C were examined. Cooling induced a rapid and reproducible contraction proportional to cooling temperature in ovine tracheal and bronchial preparations which was epithelium-independent. On readjustment to 37 degrees C the tone returned rapidly to basal level. Maximum contraction was achieved at a temperature of 5 degrees C for trachea and 15 degrees C for bronchiole. Cooling-induced contractions (CIC) was resistant to tetrodotoxin (1; 10 micrometer), and not affected by the muscarinic antagonist atropine (1 micrometer) or the alpha-adrenergic antagonist phentolamine (1 micrometer), or the histamine H1-antagonist mepyramine (1 micrometer) or indomethacin (1 micrometer). Ca2+ antagonists (nifedipine and verapamil) and Mn2+ raised tracheal but not bronchiolar tone and augmented CIC. Incubation in Ca2+-free, EGTA-containing Krebs' solution for 5 min had no effect on CIC, although it significantly reduced KCl-induced contraction by up to 75%. Cooling inhibited Ca2+ influx measured using 45Ca2+ uptake. Caffeine (100 micrometer) significantly inhibited CIC. The results show that cooling-induced contractions do not appear to involve activation of nerve endings, all surface reception systems or Ca2+ influx. However, CIC is mainly dependent on release of intracellular Ca2+. Copyright 1999 The Italian Pharmacological Society.
NASA Astrophysics Data System (ADS)
Dai, Yu; Ding, Mingde
2018-04-01
Recent observations in extreme-ultraviolet (EUV) wavelengths reveal an EUV late phase in some solar flares that is characterized by a second peak in warm coronal emissions (∼3 MK) several tens of minutes to a few hours after the soft X-ray (SXR) peak. Using the model enthalpy-based thermal evolution of loops (EBTEL), we numerically probe the production of EUV late-phase solar flares. Starting from two main mechanisms of producing the EUV late phase, i.e., long-lasting cooling and secondary heating, we carry out two groups of numerical experiments to study the effects of these two processes on the emission characteristics in late-phase loops. In either of the two processes an EUV late-phase solar flare that conforms to the observational criteria can be numerically synthesized. However, the underlying hydrodynamic and thermodynamic evolutions in late-phase loops are different between the two synthetic flare cases. The late-phase peak due to a long-lasting cooling process always occurs during the radiative cooling phase, while that powered by a secondary heating is more likely to take place in the conductive cooling phase. We then propose a new method for diagnosing the two mechanisms based on the shape of EUV late-phase light curves. Moreover, from the partition of energy input, we discuss why most solar flares are not EUV late flares. Finally, by addressing some other factors that may potentially affect the loop emissions, we also discuss why the EUV late phase is mainly observed in warm coronal emissions.
Operation of a pond-cooler: the case of Berezovskaya GRES-1
NASA Astrophysics Data System (ADS)
Morozova, O. G.; Kamoza, T. L.; Koyupchenko, I. N.; Savelyev, A. S.; Pen, R. Z.; Veselkova, N. S.; Kudryavtsev, M. D.
2017-08-01
Pond-coolers at heat and nuclear power stations are natural-technological systems, so the program of their monitoring should include the effect made by the SRPS (state regional power station) on the pond ecosystem, including thermal discharge of cooling water. The objectives of this study were development and implementation of a monitoring program for the cooling pond of Berezovskaya SRPS-1 on the chemical and biological water quality indicators and identification of patterns of the thermal and hydrochemical regime when operating the progressive power plant (from 1996 to 2015). The quality of the cooling water of the pond-cooler BGRES-1 was studied under full-scale conditions by selecting and analyzing the water samples of the pond in accordance with the principles of complexity, systematic observation, and consistency of timing their conduct with the characteristic hydrological phases. Processing of the obtained array of monitoring data by methods of mathematical statistics makes it possible to identify the main factors affecting the water quality of the pond. The data on water quality obtained during their monitoring and mathematical processing over a long time interval are the scientific basis for forecasting the ecological state of the pond, which is necessary to economically ensure the efficient energy production and safety of water use. Recommendations proposed by these authors, including those partially already implemented, have been to prevent the development of eutrophication processes in the pond-cooler: the construction of a dam that cuts off the main peat massif and cleaning the river banks forming the cooling pond.
Process design of press hardening with gradient material property influence
NASA Astrophysics Data System (ADS)
Neugebauer, R.; Schieck, F.; Rautenstrauch, A.
2011-05-01
Press hardening is currently used in the production of automotive structures that require very high strength and controlled deformation during crash tests. Press hardening can achieve significant reductions of sheet thickness at constant strength and is therefore a promising technology for the production of lightweight and energy-efficient automobiles. The manganese-boron steel 22MnB5 have been implemented in sheet press hardening owing to their excellent hot formability, high hardenability, and good temperability even at low cooling rates. However, press-hardened components have shown poor ductility and cracking at relatively small strains. A possible solution to this problem is a selective increase of steel sheet ductility by press hardening process design in areas where the component is required to deform plastically during crash tests. To this end, process designers require information about microstructure and mechanical properties as a function of the wide spectrum of cooling rates and sequences and austenitizing treatment conditions that can be encountered in production environments. In the present work, a Continuous Cooling Transformation (CCT) diagram with corresponding material properties of sheet steel 22MnB5 was determined for a wide spectrum of cooling rates. Heating and cooling programs were conducted in a quenching dilatometer. Motivated by the importance of residual elasticity in crash test performance, this property was measured using a micro-bending test and the results were integrated into the CCT diagrams to complement the hardness testing results. This information is essential for the process design of press hardening of sheet components with gradient material properties.
Process design of press hardening with gradient material property influence
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neugebauer, R.; Professorship for Machine Tools and Forming Technology, TU Chemnitz; Schieck, F.
Press hardening is currently used in the production of automotive structures that require very high strength and controlled deformation during crash tests. Press hardening can achieve significant reductions of sheet thickness at constant strength and is therefore a promising technology for the production of lightweight and energy-efficient automobiles. The manganese-boron steel 22MnB5 have been implemented in sheet press hardening owing to their excellent hot formability, high hardenability, and good temperability even at low cooling rates. However, press-hardened components have shown poor ductility and cracking at relatively small strains. A possible solution to this problem is a selective increase of steelmore » sheet ductility by press hardening process design in areas where the component is required to deform plastically during crash tests. To this end, process designers require information about microstructure and mechanical properties as a function of the wide spectrum of cooling rates and sequences and austenitizing treatment conditions that can be encountered in production environments. In the present work, a Continuous Cooling Transformation (CCT) diagram with corresponding material properties of sheet steel 22MnB5 was determined for a wide spectrum of cooling rates. Heating and cooling programs were conducted in a quenching dilatometer. Motivated by the importance of residual elasticity in crash test performance, this property was measured using a micro-bending test and the results were integrated into the CCT diagrams to complement the hardness testing results. This information is essential for the process design of press hardening of sheet components with gradient material properties.« less
NASA Astrophysics Data System (ADS)
Wobrauschek, P.; Prost, J.; Ingerle, D.; Kregsamer, P.; Misra, N. L.; Streli, C.
2015-08-01
The extension of the detectable elemental range with Total Reflection X-ray Fluorescence (TXRF) analysis is a challenging task. In this paper, it is demonstrated how a TXRF spectrometer is modified to analyze elements from carbon to uranium. Based on the existing design of a vacuum TXRF spectrometer with a 12 specimen sample changer, the following components were renewed: the silicon drift detector with 20 mm2 active area and having a special ultra-thin polymer window allowing the detection of elements from carbon upwards. Two exchangeable X-ray sources guarantee the efficient excitation of both low and high Z elements. These X-ray sources were two light-weighted easily mountable 35 W air-cooled low-power tubes with Cr and Rh anodes, respectively. The air cooled tubes and the Peltier-cooled detector allowed to construct a transportable tabletop spectrometer with compact dimensions, as neither liquid nitrogen cooling for the detector nor a water cooling circuit and a bulky high voltage generator for the X-ray tubes are required. Due to the excellent background conditions as a result of the TXRF geometry, detection limits of 150 ng for C, 12 ng for F, and 3.3 ng for Na have been obtained using Cr excitation in vacuum. For Rh excitation, the detection limits of 90 pg could be achieved for Sr. Taking 10 to 20 μl of sample volume, extrapolated detection limits in the ng/g (ppb) range are resulting in terms of concentration.
NASA Astrophysics Data System (ADS)
Liu, Wei; Berger, Thomas; Antolin, Patrick; Schrijver, Karel
2014-06-01
It has recently been recognized that a mass cycle (e.g., Berger et al. 2011; McIntosh et al. 2012) between the hot, tenuous solar corona and the cool, dense chromosphere underneath it plays an important role in the mass budget and dynamic evolution of the solar atmosphere. Although the corona ultimately loses mass through the solar wind and coronal mass ejections, a fraction of its mass returns to the chromosphere in coronal rain, downflows of prominences, and other as-yet unidentified processes. We present here analysis of joint observations of IRIS, SDO/AIA, and Hinode/SOT of such phenomena. By utilizing the wide temperature coverage (logT: 4 - 7) provided by these instruments combined, we track the coronal cooling sequence (e.g., Schrijver 2001; Liu et al. 2012; Berger et al. 2012) leading to the formation of such material at transition region or chromospheric temperatures (logT: 4 - 5) in the million-degree corona. We compare the cooling times with those expected from the radiative cooling instability. We also measure the kinematics and densities of such downflows and infer their mass fluxes, which are compared to the upward mass fluxes into the corona, e.g., those associated with spicules and flux emergence. Special attention is paid to coronal rain formed near cusp-shaped portions of coronal loops, funnel-shaped prominences at dips of coronal loops, and their respective magnetic environments. With the information about where and when such catastrophic cooling events take place, we discuss the implications for the enigmatic coronal heating mechanisms (e.g., Antolin et al. 2010).
NASA Astrophysics Data System (ADS)
Smellie, J. L.; Rocchi, S.; Armienti, P.
2011-01-01
Late Miocene (c. 13-5 Ma) volcanic sequences of the Hallett Volcanic Province (HVP) crop out along >250 km of western Ross Sea coast in northern Victoria Land. Eight primary volcanic and six sedimentary lithofacies have been identified, and they are organised into at least five different sequence architectures as a consequence of different combinations of eruptive and/or depositional conditions. The volcanoes were erupted in association with a Miocene glacial cover and the sequences are overwhelmingly glaciovolcanic. The commonest and most representative are products of mafic aa lava-fed deltas, a type of glaciovolcanic sequence that has not been described before. It is distinguished by (1) a subaerially emplaced relatively thin caprock of aa lavas lying on and passing down-dip into (2) a thicker association of chaotic to crudely bedded hyaloclastite breccias, water-chilled lava sheets and irregular lava masses, collectively called lobe-hyaloclastite. A second distinctive sequence type present is characterised by water-cooled lavas and associated sedimentary lithofacies (diamictite (probably glacigenic) and fluvial sands and gravels) similar to some mafic glaciovolcanic sheet-like sequences (see Smellie, Earth-Science Reviews, 74, 241-268, 2008), but including (for the first time) examples of likely sheet-like sequences with felsic compositions. Other sequence types in the HVP are minor and include tuff cones, cinder cones and a single ice-marginal lacustrine sequence. The glacial thermal regime varied from polar, characterised by sequences lacking glacial erosion, glacigenic sediments or evidence for free water, to temperate or sub-polar for sequences in which all of these features are conspicuously developed.
Pre-main Sequence Evolution and the Hydrogen-Burning Minimum Mass
NASA Astrophysics Data System (ADS)
Nakano, Takenori
There is a lower limit to the mass of the main-sequence stars (the hydrogen-burning minimum mass) below which the stars cannot replenish the energy lost from their surfaces with the energy released by the hydrogen burning in their cores. This is caused by the electron degeneracy in the stars which suppresses the increase of the central temperature with contraction. To find out the lower limit we need the accurate knowledge of the pre-main sequence evolution of very low-mass stars in which the effect of electron degeneracy is important. We review how Hayashi and Nakano (1963) carried out the first determination of this limit.
Reconciling mass functions with the star-forming main sequence via mergers
NASA Astrophysics Data System (ADS)
Steinhardt, Charles L.; Yurk, Dominic; Capak, Peter
2017-06-01
We combine star formation along the 'main sequence', quiescence and clustering and merging to produce an empirical model for the evolution of individual galaxies. Main-sequence star formation alone would significantly steepen the stellar mass function towards low redshift, in sharp conflict with observation. However, a combination of star formation and merging produces a consistent result for correct choice of the merger rate function. As a result, we are motivated to propose a model in which hierarchical merging is disconnected from environmentally independent star formation. This model can be tested via correlation functions and would produce new constraints on clustering and merging.
Well sealing via thermite reactions
Lowry, William Edward; Dunn, Sandra Dalvit
2016-11-15
A platform is formed in a well below a target plug zone by lowering a thermite reaction charge into the well and igniting it, whereby the products of the reaction are allowed to cool and expand to form a platform or support in the well. A main thermite reaction charge is placed above the platform and ignited to form a main sealing plug for the well. In some embodiments an upper plug is formed by igniting an upper thermite reaction charge above the main thermite reaction charge. The upper plug confines the products of ignition of the main thermite reaction charge.
Jet pump-drive system for heat removal
NASA Technical Reports Server (NTRS)
French, James R. (Inventor)
1987-01-01
The invention does away with the necessity of moving parts such as a check valve in a nuclear reactor cooling system. Instead, a jet pump, in combination with a TEMP, is employed to assure safe cooling of a nuclear reactor after shutdown. A main flow exists for a reactor coolant. A point of withdrawal is provided for a secondary flow. A TEMP, responsive to the heat from said coolant in the secondary flow path, automatically pumps said withdrawn coolant to a higher pressure and thus higher velocity compared to the main flow. The high velocity coolant is applied as a driver flow for the jet pump which has a main flow chamber located in the main flow circulation pump. Upon nuclear shutdown and loss of power for the main reactor pumping system, the TEMP/jet pump combination continues to boost the coolant flow in the direction it is already circulating. During the decay time for the nuclear reactor, the jet pump keeps running until the coolant temperature drops to a lower and safe temperature where the heat is no longer a problem. At this lower temperature, the TEMP/jet pump combination ceases its circulation boosting operation. When the nuclear reactor is restarted and the coolant again exceeds the lower temperature setting, the TEMP/jet pump automatically resumes operation. The TEMP/jet pump combination is thus automatic, self-regulating and provides an emergency pumping system free of moving parts.
NASA Technical Reports Server (NTRS)
Strom, Stephen E.; Edwards, Suzan; Strom, Karen M.
1991-01-01
The following topics were discussed: (1) current observation evidence for the presence of circumstellar disks associated with solar type pre-main sequence (PMS) stars; (2) the properties of such disks; and (3) the disk environment.
NASA Astrophysics Data System (ADS)
Zhang, C.; Koepke, J.; Kirchner, C.; Götze, N.; Behrens, H.
2014-12-01
At fast-spreading mid-ocean ridges the axial melt lenses sandwiched between the lower oceanic crust and the sheeted dike sequences are assumed to be the major magma source of oceanic crust accretion. According to the widely discussed "gabbro glacier" model, the formation of the lower oceanic crust requires efficient cooling of the axial melt lens, resulting in partly crystallization and leading to crystal-melt mush which may subside down to form the lower crust. These processes are believed to be controlled dominantly by periodical magma supply and hydrothermal circulation above melt lens. Here we quantify the cooling rate above melt lens using chemical zoning of plagioclase from hornfelsic recrystallized sheeted dikes overlying the uppermost gabbros, which are part of the dike-gabbro transition zone drilled in Hole 1256D in the Eastern equatorial Pacific by the Integrated Ocean Drilling Program, where for the first time the dike-gabbro transition zone of an intact oceanic crust was penetrated and sampled. The measured zoning patterns are supposed to be a combined result of diffusion during both on-ridge and off-ridge cooling. We estimate the on-ridge cooling rate using a forward modelling approach based on CaAl-NaSi interdiffusion in plagioclase. The results show that the recrystallized sheeted dikes have been cooled from the peak thermal overprint at 1000-1050 °C to 600 °C within about 5-30 years as a result of hydrothermal circulation above a melt lens during a period of magma starvation, corresponding to a cooling rate of 30±15 °C/yr. Heat balance calculation also approves that in order to balance the heat output of a melt lens at a fast-spreading mid-ocean ridge similar to the case of IODP Hole 1256D, the cooling rate above the melt lens is required to be around 30 °C/yr. The estimated rapid hydrothermal cooling rate coincides with the observed annual to decal episodes of melt lens fluctuation and lava eruption, which favors the "gabbro glacier" model and explains how the effective heat extraction from melt lens is achieved at fast-spreading mid-ocean ridges.
Postexercise Cooling Rates in 2 Cooling Jackets
Brade, Carly; Dawson, Brian; Wallman, Karen; Polglaze, Ted
2010-01-01
Abstract Context: Cooling jackets are a common method for removing stored heat accumulated during exercise. To date, the efficiency and practicality of different types of cooling jackets have received minimal investigation. Objective: To examine whether a cooling jacket containing a phase-change material (PC17) results in more rapid postexercise cooling than a gel cooling jacket and a no-jacket (control) condition. Design: Randomized, counterbalanced design with 3 experimental conditions. Setting: Participants exercised at 75% V̇o2max workload in a hot climate chamber (temperature = 35.0 ± 1.4°C, relative humidity = 52 ± 4%) for 30 minutes, followed by postexercise cooling for 30 minutes in cool laboratory conditions (ambient temperature = 24.9 ± 1.8°C, relative humidity = 39% ± 10%). Patients or Other Participants: Twelve physically active men (age = 21.3 ± 1.1 years, height = 182.7 ± 7.1 cm, body mass = 76.2 ± 9.5 kg, sum of 6 skinfolds = 50.5 ± 6.9 mm, body surface area = 1.98 ± 0.14 m2, V̇o2max = 49.0 ± 7.0 mL·kg−1·min−1) participated. Intervention(s): Three experimental conditions, consisting of a PC17 jacket, a gel jacket, and no jacket. Main Outcome Measure(s): Core temperature (TC), mean skin temperature (TSk), and TC cooling rate (°C/min). Results: Mean peak TC postexercise was 38.49 ± 0.42°C, 38.57 ± 0.41°C, and 38.55 ± 0.40°C for the PC17 jacket, gel jacket, and control conditions, respectively. No differences were observed in peak TC cooling rates among the PC17 jacket (0.038 ± 0.007°C/min), gel jacket (0.040 ± 0.009°C/min), and control (0.034 ± 0.010°C/min, P > .05) conditions. Between trials, no differences were calculated for mean TSk cooling. Conclusions: Similar cooling rates for all 3 conditions indicate that there is no benefit associated with wearing the PC17 or gel jacket. PMID:20210620
NASA Astrophysics Data System (ADS)
Alam, Md. Ferdous; Sazidy, Ahmad Sharif; Kabir, Asif; Mridha, Gowtam; Litu, Nazmul Alam; Rahman, Md. Ashiqur
2017-06-01
The present study aimed to evaluate the feasibility of coconut coir pads, jute fiber pads and sackcloth pads as alternative pad materials. Experimental measurements were conducted and the experimental data were quantitative. The experimental work mainly focused on the effects of different types and thicknesses of evaporative cooling pads by using forced draft fan while changing the environmental conditions. Experiments are conducted in a specifically constructed test chamber having dimensions of 12'X8'X8', using a number of cooling pads (36"X26") with a variable thickness parameters of the evaporative cooling pads i.e., 50, 75 and 100 mm. Moreover, the experimental work involved the measurement of environmental parameters such as temperature, relative humidity, air velocity, water mass flow rate and pressure drops at different times during the day. Experiments were conducted at three different water mass flow rates (0.25 kgs-1, 0.40 kgs-1 & 0.55 kgs-1) and three different air velocities (3.6 ms-1, 4.6 ms-1& 5.6 ms-1). There was a significant difference between evaporative cooling pad types and cooling efficiency. The coconut coir pads yielded maximum cooling efficiency of 85%, whereas other pads yielded the following maximum cooling efficiency: jute fiber pads 78% and sackcloth 69% for higher air velocity and minimum mass flow rate. It is found that the maximum reduction in temperature between cooling pad inlet and outlet is 4°C with a considerable increase in humidity. With the increase of pad thickness there was an increment of cooling efficiency. The results obtained for environmental factors, indicated that there was a significant difference between environmental factors and cooling efficiency. In terms of the effect of air velocity on saturation efficiency and pressure drop, higher air velocity decreases saturation efficiency and increases pressure drop across the wetted pad for maximum flow rate. Convective heat transfer co-efficient has an almost linear relationship with air Velocity. Water consumption or evaporation rate increases with the increase in air velocity. Finally, the present study indicated that the coconut coir pads perform better than the other evaporative cooling pads and have higher potential as wetted-pad material. The outcomes of this study can provide an effective and low-cost solution in the form of evaporative cooling system, especially in an agricultural country like Bangladesh.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Chih-Yuan, E-mail: chen6563@gmail.com; Department of Materials Science and Engineering, National Taiwan University, Taipei 10617, Taiwan; Yang, Jer-Ren, E-mail: jryang@ntu.edu.tw
Nanometer-sized carbides that precipitated in a Ti–Mo bearing steel after interrupted continuous cooling in a temperature range of 620–700 °C with or without hot deformation were investigated by field-emission-gun transmission electron microscopy. The nanometer-sized carbides were identified as randomly homogeneous precipitation carbides and interphase precipitation carbides coexisting in the ferrite matrix. It is found that this dual precipitation morphology of carbides in the steel leads to the non-uniform mechanical properties of individual ferrite grains. Vickers hardness data mainly revealed that, in the specimens cooled at a rate of 0.5 °C/s without hot deformation, the range of Vickers hardness distribution wasmore » 230–340 HV 0.1 when cooling was interrupted at 680 °C, and 220–360 HV 0.1 when cooling was interrupted at 650 °C. For the specimens cooled at a rate of 0.5 °C/s with hot deformation, the range of Vickers hardness distribution was 290–360 HV 0.1 when cooling was interrupted at 680 °C, and 280–340 HV 0.1 when cooling was interrupted at 650 °C. Therefore, a narrower range of hardness distribution occurred in the specimens that underwent hot deformation and were then cooled with a lower interrupted cooling temperature. The uniform precipitation status in each ferrite grain can lead to ferrite grains with a narrower Vickers hardness distribution. On the other hand, interrupted cooling produced a maximum Vickers hardness of 320–330 HV 0.1 for the hot deformed specimens and 290–310 HV 0.1 for the non-deformed specimens with cooling interrupted in the temperature range of 660–670 °C. The maximum Vickers hardness obtained in such a temperature range can be ascribed to the full precipitation of the microalloying elements in the supersaturated ferrite matrix with a tiny size (~ 4–7 nm). - Highlight: • The interrupted continuous cooling temperatures were 620 °C to 700 °C. • Precipitation carbides with dual dispersed morphology coexisted in the matrix. • Heavy hot deformation narrowed the range of hardness distribution. • Full precipitation of nano-sized carbides achieved maximum hardening.« less
The evolution of the lithium abundances of solar-type stars. II - The Ursa Major Group
NASA Technical Reports Server (NTRS)
Soderblom, David R.; Pilachowski, Catherine A.; Fedele, Stephen B.; Jones, Burton F.
1993-01-01
We draw upon a recent study of the membership of the Ursa Major Group (UMaG) to examine lithium among 0.3 Gyr old solar-type stars. For most G and K dwarfs, Li confirms the conclusions about membership in UMaG reached on the basis of kinematics and chromospheric activity. G and K dwarfs in UMaG have less Li than comparable stars in the Pleiades. This indicates that G and K dwarfs undergo Li depletion while they are on the main sequence, in addition to any pre-main-sequence depletion they may have experienced. Moreover, the Li abundances of the Pleiades K dwarfs cannot be attributed to main-sequence depletion alone, demonstrating that pre-main-sequence depletion of Li also takes place. The sun's Li abundance implies that the main-sequence mechanism becomes less effective with age. The hottest stars in UMaG have Li abundances like those of hot stars in the Pleiades and Hyades and in T Tauris, and the two genuine UMaG members with temperatures near Boesgaard's Li chasm have Li abundances consistent with that chasm developing fully by 0.3 Gyr for stars with UMaG's metallicity. We see differences in the abundance of Li between UMaG members of the same spectral types, indicating that a real spread in the lithium abundance exists within this group.
Large Eddy Simulation of complex sidearms subject to solar radiation and surface cooling.
Dittko, Karl A; Kirkpatrick, Michael P; Armfield, Steven W
2013-09-15
Large Eddy Simulation (LES) is used to model two lake sidearms subject to heating from solar radiation and cooling from a surface flux. The sidearms are part of Lake Audrey, NJ, USA and Lake Alexandrina, SA, Australia. The simulation domains are created using bathymetry data and the boundary is modelled with an Immersed Boundary Method. We investigate the cooling and heating phases with separate quasi-steady state simulations. Differential heating occurs in the cavity due to the changing depth. The resulting temperature gradients drive lateral flows. These flows are the dominant transport process in the absence of wind. Study in this area is important in water quality management as the lateral circulation can carry particles and various pollutants, transporting them to and mixing them with the main lake body. Copyright © 2013 Elsevier Ltd. All rights reserved.
Note: Control of liquid helium supply to cryopanels of Kolkata superconducting cyclotron
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhattacharyya, T. K., E-mail: tamal@vecc.gov.in; Pal, G.
2015-02-15
The Kolkata superconducting cyclotron utilises liquid helium to cool the main magnet niobium-titanium (NbTi) coil and the cryopanels. Three liquid helium cooled cryopanels, placed inside the dees of the radio-frequency system, maintain the high vacuum in the acceleration region of the superconducting cyclotron. The small cryostat placed inside the cryogenic distribution manifold located at the basement of the superconducting cyclotron building supplies liquid helium in parallel branches to three cold heads, used for cooling their associated cryopanels. The level in the cryostat has to be maintained at an optimum value to ensure uninterrupted flow of liquid helium to these threemore » cold heads. This paper describes the transfer function of the overall system, its tuning parameters, and discusses the actual control of cryostat level by using these parameters.« less
NASA Astrophysics Data System (ADS)
Yan, Zhenrong; Si, Jun
2017-09-01
The spiral coil waterwall is the main pressure parts and the core functional components of Ultra Supercritical Boiler. In the process of operation, the spiral coil waterwall is under the combined action of welding residual stress, installation defects stress and working fluid stress, Cracks and crack propagation are easy to occur in butt welds with defects. In view of the early cracks in the butt welds of more T23 water cooled walls, in this paper, the influence of various stresses on the crack propagation in the butt welds of spiral coil waterwall was studied by numerical simulation. Firstly, the welding process of T23 water cooled wall tube was simulated, and the welding residual stress field was obtained. Then,on the basis, put the working medium load on the spiral coil waterwall, the supercoated stress distribution of the welding residual stress and the stress of the working medium is obtained. Considering the bending moment formed by stagger joint which is the most common installation defects, the stress field distribution of butt welds in T23 water-cooled wall tubes was obtained by applying bending moment on the basis of the stress field of the welding residual stress and the working medium stress. The results show that, the welding residual stress is small, the effect of T23 heat treatment after welding to improve the weld quality is not obvious; The working medium load plays a great role in the hoop stress of the water cooled wall tube, and promotes the cracks in the butt welds; The axial stress on the water cooled wall tube produced by the installation defect stress is obvious, the stagger joint, and other installation defects are the main reason of crack propagation of spiral coil waterwall. It is recommended that the control the bending moment resulting from the stagger joint not exceed 756.5 NM.
NASA Astrophysics Data System (ADS)
Leloup, P. H.; Arnaud, N.; Lacassin, R.; Kienast, J. R.; Harrison, T. M.; Trong, T. T. Phan; Replumaz, A.; Tapponnier, P.
2001-04-01
New structural, petrographic, and 40Ar/39Ar data constrain the kinematics of the ASRR (Ailao Shan-Red River shear zone). In the XueLong Shan (XLS), geochronological data reveal Triassic, Early Tertiary, and Oligo-Miocene thermal events. The latter event (33-26 Ma) corresponds to cooling during left-lateral shear. In the FanSiPan (FSP) range, thrusting of the SaPa nappe, linked to left-lateral deformation, and cooling of the FSP granite occurred at ≈35 Ma. Rapid cooling resumed at 25-29 Ma as a result of uplift within the transtensive ASRR. In the DayNuiConVoi (DNCV), foliation trends NW-SE, but is deflected near large-scale shear planes. Stretching lineation is nearly horizontal. On steep foliations, shear criteria indicate left-lateral shear sense. Zones with flatter foliations show compatible shear senses. Petrographic data indicate decompression from ≈6.5 kbar during left-lateral shear (temperatures >700°C). 40Ar/39Ar data imply rapid cooling from above 350°C to below 150°C between 25 and 22 Ma without diachronism along strike. Along the whole ASRR cooling histories show two main episodes: (1) rapid cooling from peak metamorphism during left-lateral shear; (2) rapid cooling from greenschist conditions during right-lateral reactivation of the ASRR. In the NW part of the ASRR (XLS, Diancang Shan), we link rapid cooling 1 to local denudations in a transpressive environment. In the SW part (Ailao Shan and DNCV), cooling 1 resulted from regional denudation by zipper-like tectonics in a transtensive regime. The induced cooling diachronism observed in the Ailao Shan suggests left-lateral rates of 4 to 5 cm/yr from 27 Ma until ≈17 Ma. DNCV rocks always stayed in a transtensive regime and do not show cooling diachronism. The similarities of deformation kinematics along the ASRR and in the South China Sea confirms the causal link between continental strike-slip faulting and marginal basin opening.
Furuhata, Katsunori; Goto, Keiichi; Kato, Yuko; Saitou, Keiko; Sugiyama, Jun-ichi; Hara, Motonobu; Yoshida, Shin-ichi; Fukuyama, Masafumi
2007-01-01
Strain K-20, a Gram-negative, non-motile, non-spore-forming and strictly aerobic rod, which produces a pale pink pigment, was isolated from biofilm in a cooling tower in Tokyo, Japan. The taxonomic feature of the strain was studied using phenotypic tests and phylogenetic analysis. Phylogenetic analysis of 16S rRNA gene sequences showed that the strain was related to Roseomonas gilardii subsp. rosea, Roseomonas gilardii subsp. gilardii, Roseomonas cervicalis and Roseomonas mucosa at 94.3-94.6 sequence similarities. Growth occurred at 25-40 C and pH 5.0-10.0, optimal at 35 C and pH 7.0. Growth did not occur in the presence of >or=2% NaCl. The API 20NE identification system gave a positive result for urease, L-arabinose, potassium gluconate, adipic acid, malic acid and trisodium citrate (API code number 0201465). The predominant fatty acids of strain K-20 were C18:1Delta11 (50.8%) and C16:1 (17.2%). Cells contained ubiquinone 10 (Q-10) as the major quinone and the G+C content was 72.0 mol%. Based on phenotypic, chemotaxonomic and phylogenetic data, it was assumed that strain K-20 (=JCM 14634) is a novel species of the genus Roseomonas.
Shinozuka, Hiroshi; Hettiarachchige, Inoka K; Shinozuka, Maiko; Cogan, Noel O I; Spangenberg, German C; Cocks, Benjamin G; Forster, John W; Sawbridge, Timothy I
2017-08-22
Molecular characterisation has convincingly demonstrated some types of horizontal gene transfer in eukaryotes, but nuclear gene transfer between distantly related eukaryotic groups appears to have been rare. For angiosperms (flowering plants), nuclear gene transfer events identified to date have been confined to genes originating from prokaryotes or other plant species. In this report, evidence for ancient horizontal transfer of a fungal nuclear gene, encoding a ß-1,6-glucanase enzyme for fungal cell wall degradation, into an angiosperm lineage is presented for the first time. The gene was identified from de novo sequencing and assembly of the genome and transcriptome of perennial ryegrass, a cool-season grass species. Molecular analysis confirmed the presence of the complete gene in the genome of perennial ryegrass. No corresponding sequence was found in other plant species, apart from members of the Poeae sub-tribes Loliinae and Dactylidinae. Evidence suggests that a common ancestor of the two sub-tribes acquired the gene from a species ancestral to contemporary grass-associated fungal endophytes around 9-13 million years ago. This first report of horizontal transfer of a nuclear gene from a taxonomically distant eukaryote to modern flowering plants provides evidence for a novel adaptation mechanism in angiosperms.
Pleistocene climate change inferred from multi-proxy analyses of a loess-paleosol sequence in China
NASA Astrophysics Data System (ADS)
Wu, Yi; Qiu, Shifan; Fu, Shuqing; Rao, Zhiguo; Zhu, Zhaoyu
2018-04-01
The aeolian loess blanketing the Chinese Loess Plateau (CLP) is sensitive to climate change in monsoonal East Asia. Here, we present a multi-proxy climatic record from a Pleistocene loess-paleosol sequence from the Lantian Basin on the southern margin of the CLP. The measurements include magnetic susceptibility and related magnetic properties, bulk median grain-size, color reflectance, and the color-inferred hematite versus goethite ratio (Hm/Gt). A long-term aridification and cooling trend during the interval from ca 2.22-0.43 Ma is indicated by two magnetic grain-size proxies, corresponding to the global climatic cooling of the late Cenozoic. In addition, at least four intervals of climatic extremes are evident in the record of Hm/Gt ratio: at 1.71-1.65 Ma, 1.26-1.24 Ma, 0.94-0.86 Ma, and 0.62-0.48 Ma. These intervals are characterized by distinct regional climates, which contrast with the global climatic conditions represented in marine sediments. For example, a relatively arid climate is documented from 1.71 to 1.65 Ma, which was rapidly succeeded by a relatively humid climate which is associated with the earliest hominin (with an age of ca 1.63 Ma) in the Lantian Basin.
Design of refrigeration system using refrigerant R134a for macro compartment
NASA Astrophysics Data System (ADS)
Rani, M. F. H.; Razlan, Z. M.; Shahriman, A. B.; Yong, C. K.; Harun, A.; Hashim, M. S. M.; Faizi, M. K.; Ibrahim, I.; Kamarrudin, N. S.; Saad, M. A. M.; Zunaidi, I.; Wan, W. K.; Desa, H.
2017-10-01
The main objective of this study is to analyse and design an optimum cooling system for macro compartment. Current product of the refrigerator is not specified for single function and not compact in size. Hence, a refrigeration system using refrigerant R134a is aimed to provide instant cooling in a macro compartment with sizing about 150 × 150 × 250 mm. The macro compartment is purposely designed to fit a bottle or drink can, which is then cooled to a desired drinking temperature of about 8°C within a period of 1 minute. The study is not only concerned with analysing of heat load of the macro compartment containing drink can, but also focused on determining suitable heat exchanger volume for both evaporator and condenser, calculating compressor displacement value and computing suitable resistance value of the expansion valve. Method of optimization is used to obtain the best solution of the problem. Mollier diagram is necessary in the process of developing the refrigeration system. Selection of blower is made properly to allow air circulation and to increase the flow rate for higher heat transfer rate. Property data are taken precisely from thermodynamic property tables. As the main four components, namely condenser, compressor, evaporator and expansion valve are fully developed, the refrigeration system is complete.
ON THE EVOLUTION OF MAGNETIC WHITE DWARFS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tremblay, P.-E.; Fontaine, G.; Brassard, P.
We present the first radiation magnetohydrodynamic simulations of the atmosphere of white dwarf stars. We demonstrate that convective energy transfer is seriously impeded by magnetic fields when the plasma-β parameter, the thermal-to-magnetic-pressure ratio, becomes smaller than unity. The critical field strength that inhibits convection in the photosphere of white dwarfs is in the range B = 1–50 kG, which is much smaller than the typical 1–1000 MG field strengths observed in magnetic white dwarfs, implying that these objects have radiative atmospheres. We have employed evolutionary models to study the cooling process of high-field magnetic white dwarfs, where convection is entirelymore » suppressed during the full evolution (B ≳ 10 MG). We find that the inhibition of convection has no effect on cooling rates until the effective temperature (T{sub eff}) reaches a value of around 5500 K. In this regime, the standard convective sequences start to deviate from the ones without convection due to the convective coupling between the outer layers and the degenerate reservoir of thermal energy. Since no magnetic white dwarfs are currently known at the low temperatures where this coupling significantly changes the evolution, the effects of magnetism on cooling rates are not expected to be observed. This result contrasts with a recent suggestion that magnetic white dwarfs with T{sub eff} ≲ 10,000 K cool significantly slower than non-magnetic degenerates.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobsen, A. J.
In a method of the type where petrol is recovered from a mixture of petrol vapor and air by absorption of the petrol in a cooled petroleum distillate, a petroleum distillate having a boiling point range higher than that of the petrol is used, and this petroleum distillate is in sequence cooled by heat exchange with a cold reservoir, brought into direct contact with the petrol/air mixture to absorb petrol, transferred to a buffer tank and transferred from the buffer tank to a stripping means which may be a distillation column. By combining cooling condensation and absorption of the petrolmore » vapor and controlling the amount of cooled petroleum distillate brought into contact with the petrol/air mixture so that the petrol concentration in the petroleum distillate transferred to the buffer tank is substantially constant, an unprecedented optimum control of the petrol absorbing process can be obtained both in peak load and in average load operations. A system for carrying out the method is advantageous in that only the absorption means need be dimensioned for peak load operation, while the other components, such as the distillation column or a heat exchanger with associated conduits can be dimensioned for average loads, a buffer tank being provided to temporarily receive the petroleum distillate which owing to the above-mentioned control has a substantially constant, maximum petrol concentration so that the system can cope with peak loads with a surprisingly small buffer tank.« less
Latent cooling and microphysics effects in deep convection
NASA Astrophysics Data System (ADS)
Fernández-González, S.; Wang, P. K.; Gascón, E.; Valero, F.; Sánchez, J. L.
2016-11-01
Water phase changes within a storm are responsible for the enhancement of convection and therefore the elongation of its lifespan. Specifically, latent cooling absorbed during evaporation, melting and sublimation is considered the main cause of the intensification of downdrafts. In order to know more accurately the consequences of latent cooling caused by each of these processes (together with microphysical effects that they induce), four simulations were developed with the Wisconsin Dynamical and Microphysical Model (WISCDYMM): one with all the microphysical processes; other without sublimation; melting was suppressed in the third simulation; and evaporation was disabled in the fourth. The results show that sublimation cooling is not essential to maintain the vertical currents of the storm. This is demonstrated by the fact that in the simulation without sublimation, maximum updrafts are in the same range as in the control simulation, and the storm lifespan is similar or even longer. However, melting was of vital importance. The storm in the simulation without melting dissipated prematurely, demonstrating that melting is indispensable to the enhancement of downdrafts below the freezing level and for avoiding the collapse of low level updrafts. Perhaps the most important finding is the crucial influence of evaporative cooling above the freezing level that maintains and enhances mid-level downdrafts in the storm. It is believed that this latent cooling comes from the evaporation of supercooled liquid water connected with the Bergeron-Findeisen process. Therefore, besides its influence at low levels (which was already well known), this evaporative cooling is essential to strengthen mid-level downdrafts and ultimately achieve a quasi-steady state.
Two-Band, Low-Loss Microwave Window
NASA Technical Reports Server (NTRS)
Britcliffe, Michael; Franco, Manuel
2007-01-01
A window for a high-sensitivity microwave receiving system allows microwave radiation to pass through to a cryogenically cooled microwave feed system in a vacuum chamber, while keeping ambient air out of the chamber and helping to keep the interior of the chamber cold. The microwave feed system comprises a feed horn and a low-noise amplifier, both of which are required to be cooled to a temperature of 15 K during operation. The window is designed to exhibit very little microwave attenuation in two frequency bands: 8 to 9 GHz and 30 to 40 GHz. The window is 15 cm in diameter. It includes three layers (see figure): 1) The outer layer is made of a poly(tetrafluoroethylene) film 0.025 mm thick. This layer serves primarily to reflect and absorb solar ultraviolet radiation to prolong the life of the underlying main window layer, which is made of a polyimide that becomes weakened when exposed to ultraviolet. The poly(tetrafluoroethylene) layer also protects the main window layer against abrasion. Moreover, the inherent hydrophobicity of poly(tetrafluoroethylene) helps to prevent the highly undesirable accumulation of water on the outer surface. 2) The polyimide main window layer is 0.08 mm thick. This layer provides the vacuum seal for the window. 3) A 20-mm-thick layer of ethylene/ propylene copolymer foam underlies the main polyimide window layer. This foam layer acts partly as a thermal insulator: it limits radiational heating of the microwave feed horn and, concomitantly, limits radiational cooling of the window. This layer has high compressive strength and provides some mechanical support for the main window layer, reducing the strength required of the main window layer. The ethylene/propylene copolymer foam layer is attached to an aluminum window ring by means of epoxy. The outer poly(tetrafluoroethylene) film and the main polyimide window layer are sandwiched together and pressed against the window ring by use of a bolted clamp ring. The window has been found to introduce a microwave loss of only about 0.4 percent. The contribution of the window to the noise temperature of the microwave feed system has been found to be less than 1 K at 32 GHz and 0.2 K at 8.4 GHz.
Small hydraulic turbine drives
NASA Technical Reports Server (NTRS)
Rostafinski, W. A.
1970-01-01
Turbine, driven by the fluid being pumped, requires no external controls, is completely integrated into the flow system, and has bearings which utilize the main fluid for lubrication and cooling. Torque capabilities compare favorably with those developed by positive displacement hydraulic motors.
Evaluation of renewable energy alternatives for highway maintenance facilities.
DOT National Transportation Integrated Search
2013-12-01
A considerable annual energy budget is used for heating, lighting, cooling and operating ODOT : maintenance facilities. Such facilities contain vehicle repair and garage bays, which are large open : spaces with high heating demand in winter. The main...
Application of screened Coulomb potential in fitting DBV star PG 0112+104
NASA Astrophysics Data System (ADS)
Chen, Y. H.
2018-03-01
With 78.7 d of observations for PG 0112+104, a pulsating DB star, from Campaign 8 of Kepler 2 mission, Hermes et al. made a detailed mode identification. A reliable mode identification, with 5 l = 1 modes, 3 l = 2 modes, and 3 l = 1 or 2 modes, was identified. Grids of DBV star models are evolved by WDEC with element diffusion effect of pure Coulomb potential and screened Coulomb potential. Fitting the identified modes of PG 0112+104 by the calculated ones, we studied the difference of element diffusion effect between adopting pure Coulomb potential and screened Coulomb potential. Our aim is to reduce the fitting error by studying new input physics. The starting models including their chemical composition profile are from white dwarf models evolved by MESA. They were calculated following the stellar evolution from the main sequence to the start of the white dwarf cooling sequences. The optimal parameters are basically consistent with that of previous spectroscopic and asteroseismological studies. The pure and screened Coulomb potential lead to different composition profiles of the C/O-He interface area. High k modes are very sensitive to the area. However, most of the observed modes for PG 0112+104 are low k modes. The σRMS taking the screened Coulomb potential is reduced by 4 per cent compared with taking the pure Coulomb potential when fitting the identified low k modes of PG 0112+104. Fitting the Kepler 2 data with our models improved the σRMS of the fit by 27 per cent.
NASA Astrophysics Data System (ADS)
Roberts, Nicholas J.; Barendregt, René W.; Clague, John J.
2018-06-01
Continental sediments underlying the Altiplano plateau provide insight into the late Cenozoic evolution of the Central Andes. We characterize the magnetostratigraphy and lithostratigraphy of the upper part of this fill sequence along a transect extending southwestward from the Cordillera Real at La Paz, Bolivia, where it is best exposed. Multiple polarity reversals and the locally extensive, 2.74-Ma Chijini Tuff enable correlation between our six sections and three previously reported sections. The tuff ties the composite polarity sequence to the geomagnetic polarity time scale, demonstrating that the stratigraphic record extends from the latest Gilbert Chron (ca. 3.8 Ma) to the late Olduvai subchron (ca. 1.8 Ma), or possibly Jaramillo subchron (ca. 1.0 Ma). The sequence provides Earth's longest known record of low-latitude glaciation and the only record of Pliocene tropical glaciation. It includes evidence for 16 late Pliocene and Early Pleistocene glaciations, separated by interglacials of sufficient length (>103-104 a) to produce mature soil profiles. Successively larger ice caps formed directly before, during, and after the globally warm mid-Piacenzian (3.265-3.025 Ma), and throughout Plio-Pleistocene climate deterioration. The late Pliocene glacial units predate the onset of widespread Northern Hemisphere continental glaciation and in most cases unambiguously correspond to specific cool peaks of the astronomically tuned, benthic oxygen isotope (δ18O) record, including marine isotope stages MG2, M2, KM2, and G10. The glacial events broadly coincide with those nearer both poles, suggesting inter-hemispheric climate linkages. The early formation and subsequent expansion of ice caps beyond glacier margins of the Last Glacial Maximum suggest that the Cordillera Real likely attained its modern height before ca. 3.4 Ma. The number and timing of glaciations, and long-term sediment accumulation and incision rates suggest that the local Altiplano surface formed by ca. 1.8 Ma, after which headwaters of the Amazon River system breached the Cordillera Real and began to incise the fill sequence. The sequence spans at least 2 Ma before and during the first main pulses of the Great American Biotic Interchange, providing an important record of faunal migration. The arrival of savanna-adapted North American mammals in the Central Andes during this period points to the influence of glaciation on faunal migration in the southern tropics, similar to influences proposed in North and Central America.
The 2016 Mihoub (north-central Algeria) earthquake sequence: Seismological and tectonic aspects
NASA Astrophysics Data System (ADS)
Khelif, M. F.; Yelles-Chaouche, A.; Benaissa, Z.; Semmane, F.; Beldjoudi, H.; Haned, A.; Issaadi, A.; Chami, A.; Chimouni, R.; Harbi, A.; Maouche, S.; Dabbouz, G.; Aidi, C.; Kherroubi, A.
2018-06-01
On 28 May 2016 at 23:54 (UTC), an Mw5.4 earthquake occurred in Mihoub village, Algeria, 60 km southeast of Algiers. This earthquake was the largest event in a sequence recorded from 10 April to 15 July 2016. In addition to the permanent national network, a temporary network was installed in the epicentral region after this shock. Recorded event locations allow us to give a general overview of the sequence and reveal the existence of two main fault segments. The first segment, on which the first event in the sequence was located, is near-vertical and trends E-W. The second fault plane, on which the largest event of the sequence was located, dips to the southeast and strikes NE-SW. A total of 46 well-constrained focal mechanisms were calculated. The events located on the E-W-striking fault segment show mainly right-lateral strike-slip (strike N70°E, dip 77° to the SSE, rake 150°). The events located on the NE-SW-striking segment show mainly reverse faulting (strike N60°E, dip 70° to the SE, rake 130°). We calculated the static stress change caused by the first event (Md4.9) of the sequence; the result shows that the fault plane of the largest event in the sequence (Mw5.4) and most of the aftershocks occurred within an area of increased Coulomb stress. Moreover, using the focal mechanisms calculated in this work, we estimated the orientations of the main axes of the local stress tensor ellipsoid. The results confirm previous findings that the general stress field in this area shows orientations aligned NNW-SSE to NW-SE. The 2016 Mihoub earthquake sequence study thus improves our understanding of seismic hazard in north-central Algeria.
Coupled reactor kinetics and heat transfer model for heat pipe cooled reactors
NASA Astrophysics Data System (ADS)
Wright, Steven A.; Houts, Michael
2001-02-01
Heat pipes are often proposed as cooling system components for small fission reactors. SAFE-300 and STAR-C are two reactor concepts that use heat pipes as an integral part of the cooling system. Heat pipes have been used in reactors to cool components within radiation tests (Deverall, 1973); however, no reactor has been built or tested that uses heat pipes solely as the primary cooling system. Heat pipe cooled reactors will likely require the development of a test reactor to determine the main differences in operational behavior from forced cooled reactors. The purpose of this paper is to describe the results of a systems code capable of modeling the coupling between the reactor kinetics and heat pipe controlled heat transport. Heat transport in heat pipe reactors is complex and highly system dependent. Nevertheless, in general terms it relies on heat flowing from the fuel pins through the heat pipe, to the heat exchanger, and then ultimately into the power conversion system and heat sink. A system model is described that is capable of modeling coupled reactor kinetics phenomena, heat transfer dynamics within the fuel pins, and the transient behavior of heat pipes (including the melting of the working fluid). This paper focuses primarily on the coupling effects caused by reactor feedback and compares the observations with forced cooled reactors. A number of reactor startup transients have been modeled, and issues such as power peaking, and power-to-flow mismatches, and loading transients were examined, including the possibility of heat flow from the heat exchanger back into the reactor. This system model is envisioned as a tool to be used for screening various heat pipe cooled reactor concepts, for designing and developing test facility requirements, for use in safety evaluations, and for developing test criteria for in-pile and out-of-pile test facilities. .
Induction Hardening of External Gear
NASA Astrophysics Data System (ADS)
Bukanin, V. A.; Ivanov, A. N.; Zenkov, A. E.; Vologdin, V. V.; Vologdin, V. V., Jr.
2018-03-01
Problems and solution of gear induction hardening are described. Main attention is paid to the parameters of heating and cooling systems. ELTA 7.0 program has been used to obtain the required electrical parameters of inductor, power sources, resonant circuits, as well as to choose the quenching media. Comparison of experimental and calculated results of investigation is provided. In order to compare advantages and disadvantages of single- and dual-frequency heating processes, many variants of these technologies were simulated. The predicted structure and hardness of steel gears are obtained by use of the ELTA data base taken into account the Continuous Cooling Transformation diagrams.
Computer Simulation Performed for Columbia Project Cooling System
NASA Technical Reports Server (NTRS)
Ahmad, Jasim
2005-01-01
This demo shows a high-fidelity simulation of the air flow in the main computer room housing the Columbia (10,024 intel titanium processors) system. The simulation asseses the performance of the cooling system and identified deficiencies, and recommended modifications to eliminate them. It used two in house software packages on NAS supercomputers: Chimera Grid tools to generate a geometric model of the computer room, OVERFLOW-2 code for fluid and thermal simulation. This state-of-the-art technology can be easily extended to provide a general capability for air flow analyses on any modern computer room. Columbia_CFD_black.tiff
MHD thermal instabilities in cool inhomogeneous atmospheres
NASA Technical Reports Server (NTRS)
Bodo, G.; Ferrari, A.; Massaglia, S.; Rosner, R.
1983-01-01
The formation of a coronal state in a stellar atmosphere is investigated. A numerical code is used to study the effects of atmospheric gradients and finite loop dimension on the scale of unstable perturbations, solving for oscillatory perturbations as eigenfunctions of a boundary value problem. The atmosphere is considered as initially isothermal, with density and pressure having scale heights fixed by the hydrostatic equations. Joule mode instability is found to be an efficient mechanism for current filamentation and subsequent heating in initially cool atmospheres. This instability is mainly effective at the top of magnetic loops and is not suppressed by thermal conduction.
On the morphological and chemical stability of vitamin C crystals
NASA Astrophysics Data System (ADS)
Halász, Susan; Bodor, Beáta
1993-03-01
Mass cooling crystallization of aqueous vitamin C solution was studied by applying different cooling rates, initial supersaturations and mixing intensity. The morphology of the products (size, habit and colour) well followed the changes of process parameters. Comparing a high purity (99.9%) standard with a yellow coloured heterodisperse product and a slowly grown single crystal, HPLC chromatography detected decreasing purity of the bigger single crystals, while X-ray and NMR analysis did not show any perceptible difference. It has been concluded that not the surface oxidation (chemical degredation), but rather the inclusions are the main sources of impurities within the crystals.
NASA Astrophysics Data System (ADS)
Schemmer, M.; Johnson, A.; Photopoulos, R.; Bouchoule, I.
2017-04-01
The effect of atom losses on a homogeneous one-dimensional Bose gas lying within the quasicondensate regime is investigated using a Monte Carlo wave-function approach. The evolution of the system is calculated, conditioned by the loss sequence, namely, the times of individual losses and the position of the removed atoms. We describe the gas within the linearized Bogoliubov approach. For each mode, we find that, for a given quantum trajectory, the state of the system converges towards a coherent state, i.e., the ground state, displaced in phase space. We show that, provided losses are recorded with a temporal and spatially resolved detector, quantum feedback can be implemented and cooling to the ground state of one or several modes can be realized.
Melo-Ferreira, J; Boursot, P; Randi, E; Kryukov, A; Suchentrunk, F; Ferrand, N; Alves, P C
2007-02-01
The climatic fluctuations during glaciations have affected differently arctic and temperate species. In the northern hemisphere, cooling periods induced the expansion of many arctic species to the south, while temperate species were forced to retract in southern refugia. Consequently, in some areas the alternation of these species set the conditions for competition and eventually hybridization. Hares in the Iberian Peninsula appear to illustrate this phenomenon. Populations of Iberian hare (Lepus granatensis), brown hare (Lepus europaeus) and broom hare (Lepus castroviejoi) in Northern Iberia harbour mitochondrial haplotypes from the mountain hare (Lepus timidus), a mainly boreal and arctic species presently absent from the peninsula. To understand the history of this past introgression we analysed sequence variation and geographical distribution of mitochondrial control region and cytochrome b haplotypes of L. timidus origin found in 378 specimens of these four species. Among 124 L. timidus from the Northern Palaearctic and the Alps we found substantial nucleotide diversity (2.3%) but little differentiation between populations. Based on the mismatch distribution of the L. timidus sequences, this could result from an expansion at a time of temperature decrease favourable to this arctic species. The nucleotide diversity of L. timidus mtDNA found in Iberian L. granatensis, L. europaeus and L. castroviejoi (183, 70 and 1 specimens, respectively) was of the same order as that in L. timidus over its range (1.9%), suggesting repeated introgression of multiple lineages. The structure of the coalescent of L. granatensis sequences indicates that hybridization with L. timidus was followed by expansion of the introgressed haplotypes, as expected during a replacement with competition, and occurred when temperatures started to rise, favouring the temperate species. Whether a similar scenario explains the introgression into Iberian L. europaeus remains unclear but it is possible that it hybridized with already introgressed L. granatensis.
[Molecular evolution of the tick-borne encephalitis and Powassan viruses].
Subbotina, E L; Loktev, V B
2012-01-01
The problem of emerging viruses, their genetic diversity and viral evolution in nature are attracting more attention. The phylogenetic analysis and evaluationary rate estimation were made for pathogenic flaviviruses such as tick-borne encephalitis virus (TBEV) and Powassan (PV) circulated in natural foci in Russia. 47 nucleotide sequences of encoded protein E of the TBEV and 17 sequences of NS5 genome region of the PV have been used. It was found that the rate of accumulation of nucleotide substitutions for E genome region of TBEV was approximately 1.4 x 10(-4) and 5.4 x 10(-5) substitutions per site per year for NS5 genome region of PV. The ratio of non-synonymous nucleotide substitutions to synonymous substitution (dN/dS) for viral sequences were estimated of 0.049 for TBEV and 0.098 for PV. Maximum value dN/dS was 0.201-0.220 for sub-cluster of Russian and Canadian strains of PV and the minimum - 0.024 for cluster of Russian and Chinese strains of Far Eastern genotype TBEV. Evaluation of time intervals of evolutionary events associated with these viruses showed that European subtype TBEV are diverged from all-TBEV ancestor within approximately 2750 years and the Siberian and Far Eastern subtypes are emerged about 2250 years ago. The PV was introduced into natural foci of the Primorsky Krai of Russia only about 70 years ago and PV is a very close to Canadian strains of PV. Evolutionary picture for PV in North America is similar to evolution of Siberian and Far Eastern subtypes TBEV in Asia. The divergence time for main genetic groups of TBEV and PV are correlated with historical periods of warming and cooling. These allow to propose a hypothesis that climate changes were essential to the evolution of the flaviviruses in the past millenniums.
Comparative analysis of heat dissipation panels for a hybrid cooling system integrated in buildings
NASA Astrophysics Data System (ADS)
Zuazua-Ros, A.; Ramos, JC; Martín-Gómez, C.; Gómez-Acebo, Tomás; Pisano, A.
2018-05-01
The use of cooling panels as heat dissipation elements integrated in buildings has been previously investigated by the authors. Those elements would be connected to the condenser and would dissipate the heat in a passive form. Following the research, this study analyses and compares the thermal performance of two heat dissipation panels as part of a hybrid cooling system. Both panels were experimentally tested under different variables, thus having nine scenarios for each panel. Additionally, an already validated model was applied. The empirical results show a considerable difference between the cooling capacity among them, doubling the daily average ratio in one scenario. The heat dissipation ratios vary between 106 and 227 W/m2 in the first case and 140 and 413 W/m2 in the second. Regarding the model applicability, the average error for each panel was 4.0% and 8.5%. The bond between the metal sheet and the pipes of the panels has proven to be the main parameter to assure the highest heat dissipation potential of each panel.
The rapid cooling of the Nansha Block, southern South China Sea
NASA Astrophysics Data System (ADS)
Dong, M.; Zhang, J.
2017-12-01
Since the Late Cretaceous and Cenozoic, the Nansha Block has experienced a series of tectonic process and separated from South China continent to the south. As an exotic micro-continental, Nansha Block has an obvious different lithospheric rheology property from surrounding region. The lithosphere and mantle dynamic and rheology are mainly controlled by temperature. Therefore, we calculated the 3D temperature field and geothermal gradient of Nansha Block's upper mantle by using the S-wave velocity structure from surface wave tomography. The results show that the depth where temperature of 1300° as the lithospheric thickness is in close correspondence with the top of the seismic low velocity zone. The temperature of the upper mantle in Nansha Block is significantly lower than that of surrounding. It implies that Nansha Block experienced a rapid cooling event. We propose that the rapid cooling can be partly attributed to three reasons: 1) Nansha Block is a relatively stable block with no interior geothermal activity. 2) No external heat source to provide energy. 3) Abnormal mantle convection under Nansha Block accelerated the cooling.
NASA Astrophysics Data System (ADS)
Haug, M.; Haussmann, F.; Kellner, S.; Kern, L.; Eisenhauer, F.; Lizon, J.-L.; Dietrich, M.; Thummes, G.
2014-07-01
GRAVITY is a second generation VLTI instrument for high-precision narrow-angle astrometry and phase-referenced interferometric imaging in the astronomical K-band. The cryostat of the beam combiner instrument provides the required temperatures for the various subunits ranging from 40K to 290K with a milli-Kelvin temperature stability for some selected units. The bath cryostat is cooled with liquid nitrogen and makes use of the exhaust gas to cool the main optical bench to an intermediate temperature of 240K. The fringe tracking detector will be cooled separately by a single-stage pulse tube cooler to a temperature of 40K. The pulse tube cooler is optimized for minimum vibrations. In particular its warm side is connected to the 80K reservoir of the LN2 cryostat to minimize the required input power. All temperature levels are actively stabilized by electric heaters. The cold bench is supported separately from the vacuum vessel and the liquid nitrogen reservoir to minimize the transfer of acoustic noise onto the instrument.
NASA Astrophysics Data System (ADS)
Chlachula, Jiri; Krupyanko, Alexander A.
2016-06-01
The paper presents the results of Quaternary palaeoecology and geoarchaeology studies in the Zerkal'naya Basin, with new insights about sequenced natural shifts during the prehistoric occupation of this marginally explored NE Asian maritime territory. The Basin is part of the continental drainage system and the main physiographic and biotic corridor for peopling of the transitive coastal interior SE Primor'ye Region. The Final Pleistocene and Holocene environmental (biotic and abiotic) proxy records from the Upper/Final Palaeolithic to early historical sites document a dynamic climate change with vegetation cover transformations within riverine and mountain valley ecosystems of the Russian Far East. Most of the archaeological sites located on the low terraces and bedrock promontories along the main river channel and its tributary streams suggest traditional hunter gathered lifestyles based on seasonal salmon-fishing supplemented by pastoral economy. Tundra-forests with larch trees, dwarf birch thickets and polypod ferns from the basal stratigraphic units of the late Last Glacial occupation sites associated with the Upper Palaeolithic micro-blade and bifacial stone tool traditions (14C-dated to 19,000-12,000 cal yrs BP) indicate rather pronounced conditions and much lower MAT comparing today. Following a final Pleistocene cooling event, a major climate warming marked the onset of Holocene accompanied by a regional humidity increase promoting the formation of a mixed broadleaved-coniferous oak-dominant taiga, and culminating in the mid-Holocene Climatic Optimum. The appearance of mosaic parklands ca. 5,000-4,000 cal yrs BP. may be partly attributed to the expansion of the Far Eastern Neolithic cultures practicing forest clearance for pastures and dwellings. A progressing landscape opening indicated by the spread of light-demanding thickets and birch-dominated riverine biotopes with Artemisia suggests a further vegetation cover transformation during the late Neolithic and the early Palaeo-Metal (Bronze Age) periods. This trend corroborates the documented climate deterioration between 3,400 and 2,600 cal yrs BP, causing a regional aridification with a parkland-steppe broadening in the main SE Primor'ye river valleys. The late Holocene climate development persisted until the Little Ice Age which led to formation of the present settlement ecosystems with mixed (oak/cedar/fir-dominated) temperate maritime woodlands.
NASA Astrophysics Data System (ADS)
Lossada, A. C.; Mardónez, D.; Suriano, J.; Hoke, G. D.; Fitzgerald, P. G.; Mahoney, J. B.; Giambiagi, L.; Aragon, E.
2015-12-01
The South Central Andes at 30°S represent a key area to understand the Andes geodynamics as it corresponds to the flat slab segment, characterized by a subhorizontal subduction angle, absence of Neogene magmatism and a highly compressive tectonic regime. Under these settings, crustal shortening is believed to be the principal mechanism responsible for the rise of the Andes. However, the sequence of uplift of the different morphoestructural units composing the orogen is not fully understood; neither do the location and time of activity of intracrustal detachments and their connection with shallower structures. We attempt to develop a multidisciplinary analysis that allow us to characterize the timing, magnitude and activity of the principal structures involved in the construction of the Andes at 30°S trough the Coastal Range, the Frontal Cordillera and the Precordillera. The main phase of deformation in the Coastal Range occurred between 60 and 40Ma, based on published thermochronological and structural data. Our structural analyses constrain the Frontal Cordillera uplift between 18 and 13Ma. In the Precordillera area, in turn, we carried out structural, sedimentological and U-Pb provenience studies. Provenience studies and the 12 and 9Ma ages obtained for the youngest zircons indicated that the main thrusts uplifting the western sector of the Precordillera thrust system were activated since 13Ma at this latitude, and not before that time as it was previously suggested. In order to better constrain the exhumation and thermal history of Frontal Cordillera, a thermochronological study is being conducted. Twenty samples for apatite fission tracks (AFT) and apatite (U-Th)/He (AHe) were collected from two vertical profiles located at western sector (Guanta granitoid) and eastern sector (Colanguil granitoid) of the Frontal Cordillera system. Samples are currently being processed, and they are partially reseted, which will allow us to obtain a cooling age. The aim is to combine this new thermochronologic data with field observations of the geological structures and kinematic analysis of the principal features, and develop an exhumation/uplift model for the Frontal Cordillera at 30°S, which will improve our understanding of the structural evolution of this area.
Mitchell, D A; von Meien, O F
2000-04-20
Zymotis bioreactors for solid-state fermentation (SSF) are packed-bed bioreactors with internal cooling plates. This design has potential to overcome the problem of heat removal, which is one of the main challenges in SSF. In ordinary packed-bed bioreactors, which lack internal plates, large axial temperature gradients arise, leading to poor microbial growth in the end of the bed near the air outlet. The Zymotis design is suitable for SSF processes in which the substrate bed must be maintained static, but little is known about how to design and operate Zymotis bioreactors. We use a two-dimensional heat transfer model, describing the growth of Aspergillus niger on a starchy substrate, to provide guidelines for the optimum design and operation of Zymotis bioreactors. As for ordinary packed-beds, the superficial velocity of the process air is a key variable. However, the Zymotis design introduces other important variables, namely, the spacing between the internal cooling plates and the temperature of the cooling water. High productivities can be achieved at large scale, but only if small spacings between the cooling plates are used, and if the cooling water temperature is varied during the fermentation in response to bed temperatures. Copyright 2000 John Wiley & Sons, Inc.
Simulation of cooling efficiency via miniaturised channels in multilayer LTCC for power electronics
NASA Astrophysics Data System (ADS)
Pietrikova, Alena; Girasek, Tomas; Lukacs, Peter; Welker, Tilo; Müller, Jens
2017-03-01
The aim of this paper is detailed investigation of thermal resistance, flow analysis and distribution of coolant as well as thermal distribution inside multilayer LTCC substrates with embedded channels for power electronic devices by simulation software. For this reason four various structures of internal channels in the multilayer LTCC substrates were designed and simulated. The impact of the volume flow, structures of channels, and power loss of chip was simulated, calculated and analyzed by using the simulation software Mentor Graphics FloEFDTM. The structure, size and location of channels have the significant impact on thermal resistance, pressure of coolant as well as the effectivity of cooling power components (chips) that can be placed on the top of LTCC substrate. The main contribution of this paper is thermal analyze, optimization and impact of 4 various cooling channels embedded in LTCC multilayer structure. Paper investigate, the effect of volume flow in cooling channels for achieving the least thermal resistance of LTCC substrate that is loaded by power thermal chips. Paper shows on the impact of the first chips thermal load on the second chip as well as. This possible new technology could ensure in the case of practical realization effective cooling and increasing reliability of high power modules.
NASA Astrophysics Data System (ADS)
Arth, G.; Taferner, M.; Bernhard, C.; Michelic, S.
2016-07-01
Cooling strategies in continuous casting of steel can vary from rapid cooling to slow cooling, mainly controlled by adjusting the amount of water sprayed onto the surface of the product. Inadequate adjustment however can lead to local surface undercooling or reheating, leading to surface and inner defects. This paper focuses on cooling efficiency of Air-Mist nozzles on casted steel and the experimental and numerical prediction of surface temperature distributions over the product width. The first part explains the determination of heat transfer coefficients (HTC) on laboratory scale, using a so called nozzle measuring stand (NMS). Based on measured water distributions and determined HTC's for air-mist nozzles using the NMS, surface temperatures are calculated by a transient 2D-model on a simple steel plate, explained in the second part of this paper. Simulations are carried out varying water impact density and spray water distribution, consequently influencing the local HTC distribution over the plate width. Furthermore, these results will be interpreted with regard to their consequence for surface and internal quality of the cast product. The results reveal the difficulty of correct adjustment of the amount of sprayed water, concurrent influencing water distribution and thus changing HTC distribution and surface temperature.
The Production of Cold Gas Within Galaxy Outflows
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scannapieco, Evan
2017-03-01
I present a suite of three-dimensional simulations of the evolution of initially hot material ejected by starburst-driven galaxy outflows. The simulations are conducted in a comoving frame that moves with the material, tracking atomic/ionic cooling, Compton cooling, and dust cooling and destruction. Compton cooling is the most efficient of these processes, while the main role of atomic/ionic cooling is to enhance density inhomogeneities. Dust, on the other hand, has little effect on the outflow evolution, and is rapidly destroyed in all the simulations except for the case with the smallest mass flux. I use the results to construct a simplemore » steady-state model of the observed UV/optical emission from each outflow. The velocity profiles in this case are dominated by geometric effects, and the overall luminosities are extremely strong functions of the properties of the host system, as observed in ultra-luminous infrared galaxies (ULIRGs). Furthermore the luminosities and maximum velocities in several models are consistent with emission-line observations of ULIRGs, although the velocities are significantly greater than observed in absorption-line studies. It may be that absorption line observations of galaxy outflows probe entrained cold material at small radii, while emission-line observations probe cold material condensing from the initially hot medium at larger distances.« less
Shape-optimization of round-to-slot holes for improving film cooling effectiveness on a flat surface
NASA Astrophysics Data System (ADS)
Huang, Ying; Zhang, Jing-zhou; Wang, Chun-hua
2018-01-01
Single-objective optimization for improving adiabatic film cooling effectiveness is performed for single row of round-to-slot film cooling holes on a flat surface by using CFD analysis and surrogate approximation methods. Among the main geometric parameters, dimensionless hole-to-hole pitch (P/d) and slot length-to-diameter (l/d) are fixed as 2.4 and 2 respectively, and the other parameters (hole height-to-diameter ratio, slot width-to-diameter and inclination angle) are chosen as the design variables. Given a wide range of possible geometric variables, the geometric optimization of round-to-slot holes is carried out under two typical blowing ratios of M = 0.5 and M = 1.5 by selecting a spatially-averaged adiabatic film cooling effectiveness between x/d = 2 and x/d = 12 as the objective function to be maximized. Radial basis function neural network is applied for constructing the surrogate model and then the optimal design point is searched by a genetic algorithm. It is revealed that the optimal round-to-slot hole is of converging feature under a low blowing ratio but of diffusing feature under a high blowing ratio. Further, the influence principle of optimal round-to-slot geometry on film cooling performance is illustrated according to the detailed flow and thermal behaviors.
Shape-optimization of round-to-slot holes for improving film cooling effectiveness on a flat surface
NASA Astrophysics Data System (ADS)
Huang, Ying; Zhang, Jing-zhou; Wang, Chun-hua
2018-06-01
Single-objective optimization for improving adiabatic film cooling effectiveness is performed for single row of round-to-slot film cooling holes on a flat surface by using CFD analysis and surrogate approximation methods. Among the main geometric parameters, dimensionless hole-to-hole pitch ( P/ d) and slot length-to-diameter ( l/ d) are fixed as 2.4 and 2 respectively, and the other parameters (hole height-to-diameter ratio, slot width-to-diameter and inclination angle) are chosen as the design variables. Given a wide range of possible geometric variables, the geometric optimization of round-to-slot holes is carried out under two typical blowing ratios of M = 0.5 and M = 1.5 by selecting a spatially-averaged adiabatic film cooling effectiveness between x/ d = 2 and x/ d = 12 as the objective function to be maximized. Radial basis function neural network is applied for constructing the surrogate model and then the optimal design point is searched by a genetic algorithm. It is revealed that the optimal round-to-slot hole is of converging feature under a low blowing ratio but of diffusing feature under a high blowing ratio. Further, the influence principle of optimal round-to-slot geometry on film cooling performance is illustrated according to the detailed flow and thermal behaviors.
Evaporative CO2 microchannel cooling for the LHCb VELO pixel upgrade
NASA Astrophysics Data System (ADS)
de Aguiar Francisco, O. A.; Buytaert, J.; Collins, P.; Dumps, R.; John, M.; Mapelli, A.; Romagnoli, G.
2015-05-01
The LHCb Vertex Detector (VELO) will be upgraded in 2018 to a lightweight pixel detector capable of 40 MHz readout and operation in very close proximity to the LHC beams. The thermal management of the system will be provided by evaporative CO2 circulating in microchannels embedded within thin silicon plates. This solution has been selected due to the excellent thermal efficiency, the absence of thermal expansion mismatch with silicon ASICs and sensors, the radiation hardness of CO2, and very low contribution to the material budget. Although microchannel cooling is gaining considerable attention for applications related to microelectronics, it is still a novel technology for particle physics experiments, in particular when combined with evaporative CO2 cooling. The R&D effort for LHCb is focused on the design and layout of the channels together with a fluidic connector and its attachment which must withstand pressures up to 170 bar. Even distribution of the coolant is ensured by means of the use of restrictions implemented before the entrance to a race track like layout of the main cooling channels. The coolant flow and pressure drop have been simulated as well as the thermal performance of the device. This proceeding describes the design and optimization of the cooling system for LHCb and the latest prototyping results.
A Possible Mechanism for Driving Oscillations in Hot Giant Planets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dederick, Ethan; Jackiewicz, Jason, E-mail: dederiej@nmsu.edu, E-mail: jasonj@nmsu.edu
The κ -mechanism has been successful in explaining the origin of observed oscillations of many types of “classical” pulsating variable stars. Here we examine quantitatively if that same process is prominent enough to excite the potential global oscillations within Jupiter, whose energy flux is powered by gravitational collapse rather than nuclear fusion. Additionally, we examine whether external radiative forcing, i.e., starlight, could be a driver for global oscillations in hot Jupiters orbiting various main-sequence stars at defined orbital semimajor axes. Using planetary models generated by the Modules for Experiments in Stellar Astrophysics and nonadiabatic oscillation calculations, we confirm that Jovianmore » oscillations cannot be driven via the κ -mechanism. However, we do show that, in hot Jupiters, oscillations can likely be excited via the suppression of radiative cooling due to external radiation given a large enough stellar flux and the absence of a significant oscillatory damping zone within the planet. This trend does not seem to be dependent on the planetary mass. In future observations, we can thus expect that such planets may be pulsating, thereby giving greater insight into the internal structure of these bodies.« less
Race to the Top: Transiting Brown Dwarfs and Hot Jupiters
NASA Astrophysics Data System (ADS)
Beatty, Thomas G.
2015-12-01
There are currently twelve known transiting brown dwarfs, nine of which orbit single main-sequence stars. These systems give us one of the only ways in which we may directly measure the masses and radii brown dwarfs, which in turn provides strong constraints on theoretical models of brown dwarf interiors and atmospheres. In addition, the transiting brown dwarfs allow us to forge a link between our understanding of transiting hot Jupiters, and our understanding of the field brown dwarf population. Comparing the two gives us a unique avenue to explore the role and interaction of surface gravity and stellar irradiation in the atmospheres of sub-stellar objects. It also allows us to leverage the detailed spectroscopic information we have for field brown dwarfs to interpret the broadband colors of hot Jupiters. This provides us with insight into the L/T transition in brown dwarfs, and the atmospheric chemistry changes that occur in hot Jupiter atmospheres as they cool. I will discuss recent observational results, with a particular focus on the transiting brown dwarf KELT-1b, and suggest how more of these important systems may be discovered in the future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roehler, H.W.
1993-12-31
The climates, depositional environments, and geography of Eocene rocks in the greater Green River basin are investigated to determine the origin, mode of deposition, and areal distribution of the Wasatch, Green River, Bridger, and Washakie Formations. The data indicate that Eocene climates ranged from cool temperature to tropical and were affected by both terrestrial and astronomical factors. The terrestrial factors were mainly latitude, altitude, regional geography, tectonism, and volcanism. The astronomical factors are interpreted from reptitious rock sequences in the Wilkins Peak Member of the Green River Formation that record seasonal changes, 21,000 year precession of the equinox cycles, 100,000more » year eccentricity cycles, and an undetermined cycle of 727,000 years. Eight depositional environments are identified, discussed, and illustrated by diagrams, columnar sections, and photographs. They are: (1) fluvial, (2) paludal, (3) freshwater lacustrine, (4) saltwater lacustrine, (5) pond and playa lake, (6) evaporite (salt pan), (7) mudflat, and (8) volcanic and fluviovolcanic. The areal distribution of the eight depositional environments in the Wasatch, Green River, Bridger, and Washakie Formations is illustrated by photographs and 13 paleogeographic maps. 76 refs., 90 figs.« less
Finding the Onset of Convection in Main Sequence Stars
NASA Technical Reports Server (NTRS)
Simon, Theodore
2003-01-01
The primary goal of the work performed under this grant was to locate, if possible, the onset of subphotospheric convection zones in normal main sequence stars by using the presence of emission in high temperature lines in far ultraviolet spectra from the FUSE spacecraft as a proxy for convection. The change in stellar structure represented by this boundary between radiative and convective stars has always been difficult to find by other empirical means. A search was conducted through observations of a sample of A-type stars, which were somewhat hotter and more massive than the Sun, and which were carefully chosen to bridge the theoretically expected radiative/convective boundary line along the main sequence.
Lithium abundances among solar-type pre-main-sequence stars
NASA Technical Reports Server (NTRS)
Strom, Karen M.; Wilkin, Francis P.; Strom, Stephen E.; Seaman, Robert L.
1989-01-01
Measurements of Li I 6707 A line strengths were carried out for two samples of pre-main-sequence (PMS) stars (L 1641 and Taurus-Auriga), and the Li abundances estimated for PMS stars are compared with those deduced from observations of Li line strengths for main-sequence stars in the Alpha Persei cluster. It was found that the maximum Li abundances among the PMS stars with solar mass values greater than 1.0 exceed the maximum abundances for Alpha Per stars by at least 0.3 dex. Some PMS stars, including few apparently young stars, showed large (greater than 1.0 dex) Li depletion, and some apparently old PMS stars showed little or no depletion.