The Neural Network In Coordinate Transformation
NASA Astrophysics Data System (ADS)
Urusan, Ahmet Yucel
2011-12-01
In international literature, Coordinate operations is divided into two categories. They are coordinate conversion and coordinate transformation. Coordinates converted from coordinate system A to coordinate system B in the same datum (mean origine, scale and axis directions are same) by coordinate conversion. There are two different datum in coordinate transformation. The basis of each datum to a different coordinate reference system. In Coordinate transformation, coordinates are transformed from coordinate reference system A to coordinate referance system B. Geodetic studies based on physical measurements. Coordinate transformation needs identical points which were measured in each coordinate reference system (A and B). However it is difficult (and need a big reserved budget) to measure in some places like as top of mountain, boundry of countries and seaside. In this study, this sample problem solution was researched. The method of learning which is one of the neural network methods, was used for solution of this problem.
Impact and Estimation of Balance Coordinate System Rotations and Translations in Wind-Tunnel Testing
NASA Technical Reports Server (NTRS)
Toro, Kenneth G.; Parker, Peter A.
2017-01-01
Discrepancies between the model and balance coordinate systems lead to biases in the aerodynamic measurements during wind-tunnel testing. The reference coordinate system relative to the calibration coordinate system at which the forces and moments are resolved is crucial to the overall accuracy of force measurements. This paper discusses sources of discrepancies and estimates of coordinate system rotation and translation due to machining and assembly differences. A methodology for numerically estimating the coordinate system biases will be discussed and developed. Two case studies are presented using this methodology to estimate the model alignment. Examples span from angle measurement system shifts on the calibration system to discrepancies in actual wind-tunnel data. The results from these case-studies will help aerodynamic researchers and force balance engineers to better the understand and identify potential differences in calibration systems due to coordinate system rotation and translation.
Geometric calibration of a coordinate measuring machine using a laser tracking system
NASA Astrophysics Data System (ADS)
Umetsu, Kenta; Furutnani, Ryosyu; Osawa, Sonko; Takatsuji, Toshiyuki; Kurosawa, Tomizo
2005-12-01
This paper proposes a calibration method for a coordinate measuring machine (CMM) using a laser tracking system. The laser tracking system can measure three-dimensional coordinates based on the principle of trilateration with high accuracy and is easy to set up. The accuracy of length measurement of a single laser tracking interferometer (laser tracker) is about 0.3 µm over a length of 600 mm. In this study, we first measured 3D coordinates using the laser tracking system. Secondly, 21 geometric errors, namely, parametric errors of the CMM, were estimated by the comparison of the coordinates obtained by the laser tracking system and those obtained by the CMM. As a result, the estimated parametric errors agreed with those estimated by a ball plate measurement, which demonstrates the validity of the proposed calibration system.
NASA Astrophysics Data System (ADS)
LIM, M.; PARK, Y.; Jung, H.; SHIN, Y.; Rim, H.; PARK, C.
2017-12-01
To measure all components of a physical property, for example the magnetic field, is more useful than to measure its magnitude only in interpretation and application thereafter. To convert the physical property measured in 3 components on a random coordinate system, for example on moving magnetic sensor body's coordinate system, into 3 components on a fixed coordinate system, for example on geographical coordinate system, by the rotations of coordinate system around Euler angles for example, we should have the attitude values of the sensor body in time series, which could be acquired by an INS-GNSS system of which the axes are installed coincident with those of the sensor body. But if we want to install some magnetic sensors in array at sea floor but without attitude acquisition facility of the magnetic sensors and to monitor the variation of magnetic fields in time, we should have also some way to estimate the relation between the geographical coordinate system and each sensor body's coordinate system by comparison of the vectors only measured on both coordinate systems on the assumption that the directions of the measured magnetic field on both coordinate systems are the same. For that estimation, we have at least 3 ways. The first one is to calculate 3 Euler angles phi, theta, psi from the equation Vgeograph = Rx(phi) Ry(theta) Rz(psi) Vrandom, where Vgeograph is the vector on geographical coordinate system etc. and Rx(phi) is the rotation matrix around the x axis by the angle phi etc. The second one is to calculate the difference of inclination and declination between the 2 vectors on spherical coordinate system. The third one, used by us for this study, is to calculate the angle of rotation along a great circle around the rotation axis, and the direction of the rotation axis. We installed no. 1 and no. 2 FVM-400 fluxgate magnetometers in array near Cheongyang Geomagnetic Observatory (IAGA code CYG) and acquired time series of magnetic fields for CYG and for the two magnetometers. Once the angle of rotation and the direction of the rotation axis for each couple of CYG and no. 1 and of CYG and no. 2 estimated, we rotated the measured time series of vectors using quaternion rotation to get 3 time series of magnetic fields all on geographical coordinate system, which were used for tracing the moving magnetic bodies along time in that area.
Quinn, Martha; Robinson, Claire; Forman, Jane; Krein, Sarah L; Rosland, Ann-Marie
2017-07-01
Improving access can increase the providers a patient sees, and cause coordination challenges. For initiatives that increase care across health care settings, measuring patient experiences with access and care coordination will be crucial. Map existing survey measures of patient experiences with access and care coordination expected to be relevant to patients accessing care across settings. Preliminarily examine whether aspects of access and care coordination important to patients are represented by existing measures. Structured literature review of domains and existing survey measures related to access and care coordination across settings. Survey measures, and preliminary themes from semistructured interviews of 10 patients offered VA-purchased Community Care, were mapped to identified domains. We identified 31 existing survey instruments with 279 items representing 6 access and 5 care coordination domains relevant to cross-system care. Domains frequently assessed by existing measures included follow-up coordination, primary care access, cross-setting coordination, and continuity. Preliminary issues identified in interviews, but not commonly assessed by existing measures included: (1) acceptability of distance to care site given patient's clinical situation; (2) burden on patients to access and coordinate care and billing; (3) provider familiarity with Veteran culture and VA processes. Existing survey instruments assess many aspects of patient experiences with access and care coordination in cross-system care. Systems assessing cross-system care should consider whether patient surveys accurately reflect the level of patients' concerns with burden to access and coordinate care, and adequately reflect the impact of clinical severity and cultural familiarity on patient preferences.
NASA Astrophysics Data System (ADS)
Zlatkina, O. Yu
2018-04-01
There is a relationship between the service properties of component parts and their geometry; therefore, to predict and control the operational characteristics of parts and machines, it is necessary to measure their geometrical specifications. In modern production, a coordinate measuring machine is the advanced measuring instrument of the products geometrical specifications. The analysis of publications has shown that during the coordinate measurements the problems of choosing locating chart of parts and coordination have not been sufficiently studied. A special role in the coordination of the part is played by the coordinate axes informational content. Informational content is the sum of the degrees of freedom limited by the elementary item of a part. The coordinate planes of a rectangular coordinate system have different informational content (three, two, and one). The coordinate axes have informational content of four, two and zero. The higher the informational content of the coordinate plane or axis, the higher its priority for reading angular and linear coordinates is. The geometrical model production of the coordinate measurements object taking into account the information content of coordinate planes and coordinate axes allows us to clearly reveal the interrelationship of the coordinates of the deviations in location, sizes and deviations of their surfaces shape. The geometrical model helps to select the optimal locating chart of parts for bringing the machine coordinate system to the part coordinate system. The article presents an algorithm the model production of geometrical specifications using the example of the piston rod of a compressor.
Measurement system for 3-D foot coordinates and parameters
NASA Astrophysics Data System (ADS)
Liu, Guozhong; Li, Yunhui; Wang, Boxiong; Shi, Hui; Luo, Xiuzhi
2008-12-01
The 3-D foot-shape measurement system based on laser-line-scanning principle and the model of the measurement system were presented. Errors caused by nonlinearity of CCD cameras and caused by installation can be eliminated by using the global calibration method for CCD cameras, which based on nonlinear coordinate mapping function and the optimized method. A local foot coordinate system is defined with the Pternion and the Acropodion extracted from the boundaries of foot projections. The characteristic points can thus be located and foot parameters be extracted automatically by the local foot coordinate system and the related sections. Foot measurements for about 200 participants were conducted and the measurement results for male and female participants were presented. 3-D foot coordinates and parameters measurement makes it possible to realize custom-made shoe-making and shows great prosperity in shoe design, foot orthopaedic treatment, shoe size standardization, and establishment of a feet database for consumers.
A novel method of robot location using RFID and stereo vision
NASA Astrophysics Data System (ADS)
Chen, Diansheng; Zhang, Guanxin; Li, Zhen
2012-04-01
This paper proposed a new global localization method for mobile robot based on RFID (Radio Frequency Identification Devices) and stereo vision, which makes the robot obtain global coordinates with good accuracy when quickly adapting to unfamiliar and new environment. This method uses RFID tags as artificial landmarks, the 3D coordinate of the tags under the global coordinate system is written in the IC memory. The robot can read it through RFID reader; meanwhile, using stereo vision, the 3D coordinate of the tags under the robot coordinate system is measured. Combined with the robot's attitude coordinate system transformation matrix from the pose measuring system, the translation of the robot coordinate system to the global coordinate system is obtained, which is also the coordinate of the robot's current location under the global coordinate system. The average error of our method is 0.11m in experience conducted in a 7m×7m lobby, the result is much more accurate than other location method.
Study on portable optical 3D coordinate measuring system
NASA Astrophysics Data System (ADS)
Ren, Tongqun; Zhu, Jigui; Guo, Yinbiao
2009-05-01
A portable optical 3D coordinate measuring system based on digital Close Range Photogrammetry (CRP) technology and binocular stereo vision theory is researched. Three ultra-red LED with high stability is set on a hand-hold target to provide measuring feature and establish target coordinate system. Ray intersection based field directional calibrating is done for the intersectant binocular measurement system composed of two cameras by a reference ruler. The hand-hold target controlled by Bluetooth wireless communication is free moved to implement contact measurement. The position of ceramic contact ball is pre-calibrated accurately. The coordinates of target feature points are obtained by binocular stereo vision model from the stereo images pair taken by cameras. Combining radius compensation for contact ball and residual error correction, object point can be resolved by transfer of axes using target coordinate system as intermediary. This system is suitable for on-field large-scale measurement because of its excellent portability, high precision, wide measuring volume, great adaptability and satisfying automatization. It is tested that the measuring precision is near to +/-0.1mm/m.
Application of coordinate transform on ball plate calibration
NASA Astrophysics Data System (ADS)
Wei, Hengzheng; Wang, Weinong; Ren, Guoying; Pei, Limei
2015-02-01
For the ball plate calibration method with coordinate measurement machine (CMM) equipped with laser interferometer, it is essential to adjust the ball plate parallel to the direction of laser beam. It is very time-consuming. To solve this problem, a method based on coordinate transformation between machine system and object system is presented. With the fixed points' coordinates of the ball plate measured in the object system and machine system, the transformation matrix between the coordinate systems is calculated. The laser interferometer measurement data error due to the placement of ball plate can be corrected with this transformation matrix. Experimental results indicate that this method is consistent with the handy adjustment method. It avoids the complexity of ball plate adjustment. It also can be applied to the ball beam calibration.
Baumer, Timothy G; Giles, Joshua W; Drake, Anne; Zauel, Roger; Bey, Michael J
2016-01-01
Measures of scapulothoracic motion are dependent on accurate imaging of the scapula and thorax. Advanced radiographic techniques can provide accurate measures of scapular motion, but the limited 3D imaging volume of these techniques often precludes measurement of thorax motion. To overcome this, a thorax coordinate system was defined based on the position of rib pairs and then compared to a conventional sternum/spine-based thorax coordinate system. Alignment of the rib-based coordinate system was dependent on the rib pairs used, with the rib3:rib4 pairing aligned to within 4.4 ± 2.1 deg of the conventional thorax coordinate system.
A systematic review of the care coordination measurement landscape
2013-01-01
Background Care coordination has increasingly been recognized as an important aspect of high-quality health care delivery. Robust measures of coordination processes will be essential tools to evaluate, guide and support efforts to understand and improve coordination, yet little agreement exists among stakeholders about how to best measure care coordination. We aimed to review and characterize existing measures of care coordination processes and identify areas of high and low density to guide future measure development. Methods We conducted a systematic review of measures published in MEDLINE through April 2012 and identified from additional key sources and informants. We characterized included measures with respect to the aspects of coordination measured (domain), measurement perspective (patient/family, health care professional, system representative), applicable settings and patient populations (by age and condition), and data used (survey, chart review, administrative claims). Results Among the 96 included measure instruments, most relied on survey methods (88%) and measured aspects of communication (93%), in particular the transfer of information (81%). Few measured changing coordination needs (11%). Nearly half (49%) of instruments mapped to the patient/family perspective; 29% to the system representative and 27% to the health care professionals perspective. Few instruments were applicable to settings other than primary care (58%), inpatient facilities (25%), and outpatient specialty care (22%). Conclusions New measures are needed that evaluate changing coordination needs, coordination as perceived by health care professionals, coordination in the home health setting, and for patients at the end of life. PMID:23537350
Optical 3D-coordinate measuring system using structured light
NASA Astrophysics Data System (ADS)
Schreiber, Wolfgang; Notni, Gunther; Kuehmstedt, Peter; Gerber, Joerg; Kowarschik, Richard M.
1996-09-01
The paper is aimed at the description of an optical shape measuring technique based on a consistent principle using fringe projection technique. We demonstrate a real 3D- coordinate measuring system where the sale of coordinates is given only by the illumination-structures. This method has the advantages that the aberration of the observing system and the depth-dependent imaging scale have no influence on the measuring accuracy and, moreover, the measurements are independent of the position of the camera with respect to the object under test. Furthermore, it is shown that the influence of specular effects of the surface on the measuring result can be eliminated. Moreover, we developed a very simple algorithm to calibrate the measuring system. The measuring examples show that a measuring accuracy of 10-4 (i.e. 10 micrometers ) within an object volume of 100 X 100 X 70 mm3 is achievable. Furthermore, it is demonstrated that the set of coordinate values can be processed in CNC- and CAD-systems.
Coordinate alignment of combined measurement systems using a modified common points method
NASA Astrophysics Data System (ADS)
Zhao, G.; Zhang, P.; Xiao, W.
2018-03-01
The co-ordinate metrology has been extensively researched for its outstanding advantages in measurement range and accuracy. The alignment of different measurement systems is usually achieved by integrating local coordinates via common points before measurement. The alignment errors would accumulate and significantly reduce the global accuracy, thus need to be minimized. In this thesis, a modified common points method (MCPM) is proposed to combine different traceable system errors of the cooperating machines, and optimize the global accuracy by introducing mutual geometric constraints. The geometric constraints, obtained by measuring the common points in individual local coordinate systems, provide the possibility to reduce the local measuring uncertainty whereby enhance the global measuring certainty. A simulation system is developed in Matlab to analyze the feature of MCPM using the Monto-Carlo method. An exemplary setup is constructed to verify the feasibility and efficiency of the proposed method associated with laser tracker and indoor iGPS systems. Experimental results show that MCPM could significantly improve the alignment accuracy.
Huang, B Y; Durrant, C J; Johnson, C W L; Murray, G M
2002-06-30
Previous studies have indicated that the location of a condylar point can significantly influence its trajectory. The aim of this investigation was to develop a method of registering the location of radiographically defined condylar points in the coordinate system of a six-degree-of-freedom jaw-tracking device and to determine the accuracy of this method by using a perspex model in one experiment and a dry skull in another. A direct measurement ('the gold standard') of condylar point coordinates in the coordinate system of JAWS3D was done using a three-dimensional (3D) digitizer (MicroScribe-3DX). The indirect measurement used a distributed fiducial marker as the interface between the coordinate system of MicroScribe-3DX (which was used to register the fiducial marker and the JAWS3D coordinate system) and the coordinate system of the CT scans (used to define condyle anatomy and the relation with the fiducial marker). The coordinates of condylar points could then be calculated in the coordinate system of JAWS3D. The results showed that the indirect method could register condylar point coordinates on either side to an accuracy of approximately 0.5 mm.
Dong, Ren G; Sinsel, Erik W; Welcome, Daniel E; Warren, Christopher; Xu, Xueyan S; McDowell, Thomas W; Wu, John Z
2015-09-01
The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study.
Dong, Ren G.; Sinsel, Erik W.; Welcome, Daniel E.; Warren, Christopher; Xu, Xueyan S.; McDowell, Thomas W.; Wu, John Z.
2015-01-01
The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study. PMID:26929824
A three dimensional point cloud registration method based on rotation matrix eigenvalue
NASA Astrophysics Data System (ADS)
Wang, Chao; Zhou, Xiang; Fei, Zixuan; Gao, Xiaofei; Jin, Rui
2017-09-01
We usually need to measure an object at multiple angles in the traditional optical three-dimensional measurement method, due to the reasons for the block, and then use point cloud registration methods to obtain a complete threedimensional shape of the object. The point cloud registration based on a turntable is essential to calculate the coordinate transformation matrix between the camera coordinate system and the turntable coordinate system. We usually calculate the transformation matrix by fitting the rotation center and the rotation axis normal of the turntable in the traditional method, which is limited by measuring the field of view. The range of exact feature points used for fitting the rotation center and the rotation axis normal is approximately distributed within an arc less than 120 degrees, resulting in a low fit accuracy. In this paper, we proposes a better method, based on the invariant eigenvalue principle of rotation matrix in the turntable coordinate system and the coordinate transformation matrix of the corresponding coordinate points. First of all, we control the rotation angle of the calibration plate with the turntable to calibrate the coordinate transformation matrix of the corresponding coordinate points by using the least squares method. And then we use the feature decomposition to calculate the coordinate transformation matrix of the camera coordinate system and the turntable coordinate system. Compared with the traditional previous method, it has a higher accuracy, better robustness and it is not affected by the camera field of view. In this method, the coincidence error of the corresponding points on the calibration plate after registration is less than 0.1mm.
NASA Astrophysics Data System (ADS)
Liu, W. L.; Li, Y. W.
2017-09-01
Large-scale dimensional metrology usually requires a combination of multiple measurement systems, such as laser tracking, total station, laser scanning, coordinate measuring arm and video photogrammetry, etc. Often, the results from different measurement systems must be combined to provide useful results. The coordinate transformation is used to unify coordinate frames in combination; however, coordinate transformation uncertainties directly affect the accuracy of the final measurement results. In this paper, a novel method is proposed for improving the accuracy of coordinate transformation, combining the advantages of the best-fit least-square and radial basis function (RBF) neural networks. First of all, the configuration of coordinate transformation is introduced and a transformation matrix containing seven variables is obtained. Second, the 3D uncertainty of the transformation model and the residual error variable vector are established based on the best-fit least-square. Finally, in order to optimize the uncertainty of the developed seven-variable transformation model, we used the RBF neural network to identify the uncertainty of the dynamic, and unstructured, owing to its great ability to approximate any nonlinear function to the designed accuracy. Intensive experimental studies were conducted to check the validity of the theoretical results. The results show that the mean error of coordinate transformation decreased from 0.078 mm to 0.054 mm after using this method in contrast with the GUM method.
NASA Astrophysics Data System (ADS)
Shirenin, A. M.; Mazurova, E. M.; Bagrov, A. V.
2016-11-01
The paper presents a mathematical algorithm for processing an array of angular measurements of light beacons on images of the lunar surface onboard a polar artificial lunar satellite (PALS) during the Luna-Glob mission and coordinate-time referencing of the PALS for the development of reference selenocentric coordinate systems. The algorithm makes it possible to obtain angular positions of point light beacons located on the surface of the Moon in selenocentric celestial coordinates. The operation of measurement systems that determine the position and orientation of the PALS during its active existence have been numerically simulated. Recommendations have been made for the optimal use of different types of measurements, including ground radio trajectory measurements, navigational star sensors based on the onboard star catalog, gyroscopic orientation systems, and space videos of the lunar surface.
NASA Technical Reports Server (NTRS)
Britt, C. L., Jr.
1975-01-01
The development of an RF Multilateration system to provide accurate position and velocity measurements during the approach and landing phase of Vertical Takeoff Aircraft operation is discussed. The system uses an angle-modulated ranging signal to provide both range and range rate measurements between an aircraft transponder and multiple ground stations. Range and range rate measurements are converted to coordinate measurements and the coordinate and coordinate rate information is transmitted by an integral data link to the aircraft. Data processing techniques are analyzed to show advantages and disadvantages. Error analyses are provided to permit a comparison of the various techniques.
Photogrammetry Tool for Forensic Analysis
NASA Technical Reports Server (NTRS)
Lane, John
2012-01-01
A system allows crime scene and accident scene investigators the ability to acquire visual scene data using cameras for processing at a later time. This system uses a COTS digital camera, a photogrammetry calibration cube, and 3D photogrammetry processing software. In a previous instrument developed by NASA, the laser scaling device made use of parallel laser beams to provide a photogrammetry solution in 2D. This device and associated software work well under certain conditions. In order to make use of a full 3D photogrammetry system, a different approach was needed. When using multiple cubes, whose locations relative to each other are unknown, a procedure that would merge the data from each cube would be as follows: 1. One marks a reference point on cube 1, then marks points on cube 2 as unknowns. This locates cube 2 in cube 1 s coordinate system. 2. One marks reference points on cube 2, then marks points on cube 1 as unknowns. This locates cube 1 in cube 2 s coordinate system. 3. This procedure is continued for all combinations of cubes. 4. The coordinate of all of the found coordinate systems is then merged into a single global coordinate system. In order to achieve maximum accuracy, measurements are done in one of two ways, depending on scale: when measuring the size of objects, the coordinate system corresponding to the nearest cube is used, or when measuring the location of objects relative to a global coordinate system, a merged coordinate system is used. Presently, traffic accident analysis is time-consuming and not very accurate. Using cubes with differential GPS would give absolute positions of cubes in the accident area, so that individual cubes would provide local photogrammetry calibration to objects near a cube.
Free-form surface measuring method based on optical theodolite measuring system
NASA Astrophysics Data System (ADS)
Yu, Caili
2012-10-01
The measurement for single-point coordinate, length and large-dimension curved surface in industrial measurement can be achieved through forward intersection measurement by the theodolite measuring system composed of several optical theodolites and one computer. The measuring principle of flexible large-dimension three-coordinate measuring system made up of multiple (above two) optical theodolites and composition and functions of the system have been introduced in this paper. Especially for measurement of curved surface, 3D measured data of spatial free-form surface is acquired through the theodolite measuring system and the CAD model is formed through surface fitting to directly generate CAM processing data.
Parsimonious description for predicting high-dimensional dynamics
Hirata, Yoshito; Takeuchi, Tomoya; Horai, Shunsuke; Suzuki, Hideyuki; Aihara, Kazuyuki
2015-01-01
When we observe a system, we often cannot observe all its variables and may have some of its limited measurements. Under such a circumstance, delay coordinates, vectors made of successive measurements, are useful to reconstruct the states of the whole system. Although the method of delay coordinates is theoretically supported for high-dimensional dynamical systems, practically there is a limitation because the calculation for higher-dimensional delay coordinates becomes more expensive. Here, we propose a parsimonious description of virtually infinite-dimensional delay coordinates by evaluating their distances with exponentially decaying weights. This description enables us to predict the future values of the measurements faster because we can reuse the calculated distances, and more accurately because the description naturally reduces the bias of the classical delay coordinates toward the stable directions. We demonstrate the proposed method with toy models of the atmosphere and real datasets related to renewable energy. PMID:26510518
Huang, Junhui; Xue, Qi; Wang, Zhao; Gao, Jianmin
2016-09-03
While color-coding methods have improved the measuring efficiency of a structured light three-dimensional (3D) measurement system, they decreased the measuring accuracy significantly due to lateral chromatic aberration (LCA). In this study, the LCA in a structured light measurement system is analyzed, and a method is proposed to compensate the error caused by the LCA. Firstly, based on the projective transformation, a 3D error map of LCA is constructed in the projector images by using a flat board and comparing the image coordinates of red, green and blue circles with the coordinates of white circles at preselected sample points within the measurement volume. The 3D map consists of the errors, which are the equivalent errors caused by LCA of the camera and projector. Then in measurements, error values of LCA are calculated and compensated to correct the projector image coordinates through the 3D error map and a tri-linear interpolation method. Eventually, 3D coordinates with higher accuracy are re-calculated according to the compensated image coordinates. The effectiveness of the proposed method is verified in the following experiments.
Huang, Junhui; Xue, Qi; Wang, Zhao; Gao, Jianmin
2016-01-01
While color-coding methods have improved the measuring efficiency of a structured light three-dimensional (3D) measurement system, they decreased the measuring accuracy significantly due to lateral chromatic aberration (LCA). In this study, the LCA in a structured light measurement system is analyzed, and a method is proposed to compensate the error caused by the LCA. Firstly, based on the projective transformation, a 3D error map of LCA is constructed in the projector images by using a flat board and comparing the image coordinates of red, green and blue circles with the coordinates of white circles at preselected sample points within the measurement volume. The 3D map consists of the errors, which are the equivalent errors caused by LCA of the camera and projector. Then in measurements, error values of LCA are calculated and compensated to correct the projector image coordinates through the 3D error map and a tri-linear interpolation method. Eventually, 3D coordinates with higher accuracy are re-calculated according to the compensated image coordinates. The effectiveness of the proposed method is verified in the following experiments. PMID:27598174
Using the auxiliary camera for system calibration of 3D measurement by digital speckle
NASA Astrophysics Data System (ADS)
Xue, Junpeng; Su, Xianyu; Zhang, Qican
2014-06-01
The study of 3D shape measurement by digital speckle temporal sequence correlation have drawn a lot of attention by its own advantages, however, the measurement mainly for depth z-coordinate, horizontal physical coordinate (x, y) are usually marked as image pixel coordinate. In this paper, a new approach for the system calibration is proposed. With an auxiliary camera, we made up the temporary binocular vision system, which are used for the calibration of horizontal coordinates (mm) while the temporal sequence reference-speckle-sets are calibrated. First, the binocular vision system has been calibrated using the traditional method. Then, the digital speckles are projected on the reference plane, which is moved by equal distance in the direction of depth, temporal sequence speckle images are acquired with camera as reference sets. When the reference plane is in the first position and final position, crossed fringe pattern are projected to the plane respectively. The control points of pixel coordinates are extracted by Fourier analysis from the images, and the physical coordinates are calculated by the binocular vision. The physical coordinates corresponding to each pixel of the images are calculated by interpolation algorithm. Finally, the x and y corresponding to arbitrary depth value z are obtained by the geometric formula. Experiments prove that our method can fast and flexibly measure the 3D shape of an object as point cloud.
DuGoff, Eva H; Dy, Sydney; Giovannetti, Erin R; Leff, Bruce; Boyd, Cynthia M
2013-01-01
The primary study objective is to assess how three major health reform care coordination initiatives (Accountable Care Organizations, Independence at Home, and Community-Based Care Transitions) measure concepts critical to care coordination for people with multiple chronic conditions. We find that there are major differences in quality measurement across these three large and politically important programs. Quality measures currently used or proposed for these new health reform-related programs addressing care coordination primarily capture continuity of care. Other key areas of care coordination, such as care transitions, patient-centeredness, and cross-cutting care across multiple conditions are infrequently addressed. The lack of a comprehensive and consistent measure set for care coordination will pose challenges for healthcare providers and policy makers who seek, respectively, to provide and reward well-coordinated care. In addition, this heterogeneity in measuring care coordination quality will generate new information, but will inhibit comparisons between these care coordination programs. © 2013 National Association for Healthcare Quality.
DuGoff, Eva H.; Dy, Sydney; Giovannetti, Erin R.; Leff, Bruce; Boyd, Cynthia M.
2015-01-01
The primary study objective is to assess how three major health reform care coordination initiatives (Accountable Care Organizations, Independence at Home, and Community-based Care Transitions) measure concepts critical to care coordination for people with multiple chronic conditions. We find that there are major differences in quality measurement across these three large and politically important programs. Quality measures currently used or proposed for these new health reform-related programs addressing care coordination primarily capture continuity of care. Other key areas of care coordination, such as care transitions, patient-centeredness, and cross-cutting care across multiple conditions are infrequently addressed. The lack of a comprehensive and consistent measure set for care coordination will pose challenges for health care providers and policymakers who seek, respectively, to provide and reward well-coordinated care. In addition, this heterogeneity in measuring care coordination quality will generate new information, but will inhibit comparisons between these care coordination programs. PMID:24004040
Flexible coordinate measurement system based on robot for industries
NASA Astrophysics Data System (ADS)
Guo, Yin; Yang, Xue-you; Liu, Chang-jie; Ye, Sheng-hua
2010-10-01
The flexible coordinate measurement system based on robot which is applicable to multi-model vehicle is designed to meet the needs of online measurement for current mainstream mixed body-in-white(BIW) production line. The moderate precision, good flexibility and no blind angle are the benefits of this measurement system. According to the measurement system, a monocular structured light vision sensor has been designed, which can measure not only edges, but also planes, apertures and other features. And a effective way to fast on-site calibration of the whole system using the laser tracker has also been proposed, which achieves the unity of various coordinate systems in industrial fields. The experimental results show satisfactory precision of +/-0.30mm of this measurement system, which is sufficient for the needs of online measurement for body-in-white(BIW) in the auto production line. The system achieves real-time detection and monitoring of the whole process of the car body's manufacture, and provides a complete data support in purpose of overcoming the manufacturing error immediately and accurately and improving the manufacturing precision.
Quantifying alignment effects in 3D coordinate measurement.
DOT National Transportation Integrated Search
2009-10-01
The use of fixtureless, non-contact coordinate measurement has become increasingly prevalent in manufacturing : problem solving. Manufacturers now routinely use measurement systems such as white light area scanners, photogrammetry, : laser trackers, ...
Krzysztof, Naus; Aleksander, Nowak
2016-01-01
The article presents a study of the accuracy of estimating the position coordinates of BAUV (Biomimetic Autonomous Underwater Vehicle) by the extended Kalman filter (EKF) method. The fusion of movement parameters measurements and position coordinates fixes was applied. The movement parameters measurements are carried out by on-board navigation devices, while the position coordinates fixes are done by the USBL (Ultra Short Base Line) system. The problem of underwater positioning and the conceptual design of the BAUV navigation system constructed at the Naval Academy (Polish Naval Academy—PNA) are presented in the first part of the paper. The second part consists of description of the evaluation results of positioning accuracy, the genesis of the problem of selecting method for underwater positioning, and the mathematical description of the method of estimating the position coordinates using the EKF method by the fusion of measurements with on-board navigation and measurements obtained with the USBL system. The main part contains a description of experimental research. It consists of a simulation program of navigational parameter measurements carried out during the BAUV passage along the test section. Next, the article covers the determination of position coordinates on the basis of simulated parameters, using EKF and DR methods and the USBL system, which are then subjected to a comparative analysis of accuracy. The final part contains systemic conclusions justifying the desirability of applying the proposed fusion method of navigation parameters for the BAUV positioning. PMID:27537884
Krzysztof, Naus; Aleksander, Nowak
2016-08-15
The article presents a study of the accuracy of estimating the position coordinates of BAUV (Biomimetic Autonomous Underwater Vehicle) by the extended Kalman filter (EKF) method. The fusion of movement parameters measurements and position coordinates fixes was applied. The movement parameters measurements are carried out by on-board navigation devices, while the position coordinates fixes are done by the USBL (Ultra Short Base Line) system. The problem of underwater positioning and the conceptual design of the BAUV navigation system constructed at the Naval Academy (Polish Naval Academy-PNA) are presented in the first part of the paper. The second part consists of description of the evaluation results of positioning accuracy, the genesis of the problem of selecting method for underwater positioning, and the mathematical description of the method of estimating the position coordinates using the EKF method by the fusion of measurements with on-board navigation and measurements obtained with the USBL system. The main part contains a description of experimental research. It consists of a simulation program of navigational parameter measurements carried out during the BAUV passage along the test section. Next, the article covers the determination of position coordinates on the basis of simulated parameters, using EKF and DR methods and the USBL system, which are then subjected to a comparative analysis of accuracy. The final part contains systemic conclusions justifying the desirability of applying the proposed fusion method of navigation parameters for the BAUV positioning.
NASA Astrophysics Data System (ADS)
Deng, Zhengping; Li, Shuanggao; Huang, Xiang
2018-06-01
In the assembly process of large-size aerospace products, the leveling and horizontal alignment of large components are essential prior to the installation of an inertial navigation system (INS) and the final quality inspection. In general, the inherent coordinate systems of large-scale coordinate measuring devices are not coincident with the geodetic horizontal system, and a dual-axis compensation system is commonly required for the measurement of difference in heights. These compensation systems are expensive and dedicated designs for different devices at present. Considering that a large-size assembly site usually needs more than one measuring device, a compensation approach which is versatile for different devices would be a more convenient and economic choice for manufacturers. In this paper, a flexible and cost-effective compensation method is proposed. Firstly, an auxiliary measuring device called a versatile compensation fixture (VCF) is designed, which mainly comprises reference points for coordinate transformation and a dual-axis inclinometer, and a kind of network tighten points (NTPs) are introduced and temporarily deployed in the large measuring space to further reduce transformation error. Secondly, the measuring principle of height difference is studied, based on coordinate transformation theory and trigonometry while considering the effects of earth curvature, and the coordinate transformation parameters are derived by least squares adjustment. Thirdly, the analytical solution of leveling uncertainty is analyzed, based on which the key parameters of the VCF and the proper deployment of NTPs are determined according to the leveling accuracy requirement. Furthermore, the proposed method is practically applied to the assembly of a large helicopter by developing an automatic leveling and alignment system. By measuring four NTPs, the leveling uncertainty (2σ) is reduced by 29.4% to about 0.12 mm, compared with that without NTPs.
Weaver, Brian T; Braman, Jerrod E; Haut, Roger C
2016-06-01
A direct method to express the center of pressure (CoP) measured by an insole pressure sensor system (IPSS) into a known coordinate system measured by motion tracking equipment is presented. A custom probe was constructed with reflective markers to allow its tip to be precisely tracked with motion tracking equipment. This probe was utilized to activate individual sensors on an IPSS that was placed in a shoe fitted with reflective markers used to establish a local shoe coordinate system. When pressed onto the IPSS the location of the probe's tip was coincident with the CoP measured by the IPSS (IPSS-CoP). Two separate pushes (i.e., data points) were used to develop vectors in each respective coordinate system. Simple vector mathematics determined the rotational and translational components of the transformation matrix needed to express the IPSS-CoP into the local shoe coordinate system. Validation was performed by comparing IPSS-CoP with an embedded force plate measured CoP (FP-CoP) from data gathered during kinematic trials. Six male subjects stood on an embedded FP and performed anterior/posterior (AP) sway, internal rotation, and external rotation of the body relative to a firmly planted foot. The IPSS-CoP was highly correlated with the FP-CoP for all motions, root mean square errors (RMSRRs) were comparable to other research, and there were no statistical differences between the displacement of the IPSS-CoP and FP-CoP for both the AP and medial/lateral (ML) axes, respectively. The results demonstrated that this methodology could be utilized to determine the transformation variables need to express IPSS-CoP into a known coordinate system measured by motion tracking equipment and that these variables can be determined outside the laboratory anywhere motion tracking equipment is available.
D Coordinate Transformation Using Artificial Neural Networks
NASA Astrophysics Data System (ADS)
Konakoglu, B.; Cakır, L.; Gökalp, E.
2016-10-01
Two coordinate systems used in Turkey, namely the ED50 (European Datum 1950) and ITRF96 (International Terrestrial Reference Frame 1996) coordinate systems. In most cases, it is necessary to conduct transformation from one coordinate system to another. The artificial neural network (ANN) is a new method for coordinate transformation. One of the biggest advantages of the ANN is that it can determine the relationship between two coordinate systems without a mathematical model. The aim of this study was to investigate the performances of three different ANN models (Feed Forward Back Propagation (FFBP), Cascade Forward Back Propagation (CFBP) and Radial Basis Function Neural Network (RBFNN)) with regard to 2D coordinate transformation. To do this, three data sets were used for the same study area, the city of Trabzon. The coordinates of data sets were measured in the ED50 and ITRF96 coordinate systems by using RTK-GPS technique. Performance of each transformation method was investigated by using the coordinate differences between the known and estimated coordinates. The results showed that the ANN algorithms can be used for 2D coordinate transformation in cases where optimum model parameters are selected.
Applications of laser ranging and VLBI observations for selenodetic control
NASA Technical Reports Server (NTRS)
Fajemirokun, F. A.
1971-01-01
The observation equations necessary to utilize lunar laser ranging and very long baseline interferometry measurements were developed for the establishment of a primary control network on the moon. The network consists of coordinates of moon points in the selenodetic Cartesian coordinate system, which is fixed to the lunar body, oriented along the three principal axes of inertia of the moon, and centered at the lunar center of mass. The observation equations derived are based on a general model in which the unknown parameters included: the selenodetic Cartesian coordinates, the geocentric coordinates of earth stations, parameters of the orientation of the selenodetic coordinate system with respect to a fixed celestial system, the parameters of the orientation of the average terrestrial coordinate system with respect to a fixed celestial coordinate system, and the geocentric coordinates of the center of mass of the moon, given by a lunar ephemeris.
NASA Astrophysics Data System (ADS)
Carmignato, Simone
2009-01-01
Optical sensors are increasingly used for dimensional and geometrical metrology. However, the lack of international standards for testing optical coordinate measuring systems is currently limiting the traceability of measurements and the easy comparison of different optical systems. This paper presents an experimental investigation on artefacts and procedures for testing coordinate measuring systems equipped with optical distance sensors. The work is aimed at contributing to the standardization of testing methods. The VDI/VDE 2617-6.2:2005 guideline, which is probably the most complete document available at the state of the art for testing systems with optical distance sensors, is examined with specific experiments. Results from the experiments are discussed, with particular reference to the tests used for determining the following characteristics: error of indication for size measurement, probing error and structural resolution. Particular attention is given to the use of artefacts alternative to gauge blocks for determining the error of indication for size measurement.
NASA Technical Reports Server (NTRS)
Poehler, H. A.
1977-01-01
For a summer thunderstorm, for which simultaneous, airborne electric field measurements and Lightning Detection and Ranging (LDAR) System data was available, measurements were coordinated to present a picture of the electric field intensity near cloud electrical discharges detected by the LDAR System. Radar precipitation echos from NOAA's 10 cm weather radar and measured airborne electric field intensities were superimposed on LDAR PPI plots to present a coordinated data picture of thunderstorm activity.
NASA Astrophysics Data System (ADS)
Xie, Hongbo; Mao, Chensheng; Ren, Yongjie; Zhu, Jigui; Wang, Chao; Yang, Lei
2017-10-01
In high precision and large-scale coordinate measurement, one commonly used approach to determine the coordinate of a target point is utilizing the spatial trigonometric relationships between multiple laser transmitter stations and the target point. A light receiving device at the target point is the key element in large-scale coordinate measurement systems. To ensure high-resolution and highly sensitive spatial coordinate measurement, a high-performance and miniaturized omnidirectional single-point photodetector (OSPD) is greatly desired. We report one design of OSPD using an aspheric lens, which achieves an enhanced reception angle of -5 deg to 45 deg in vertical and 360 deg in horizontal. As the heart of our OSPD, the aspheric lens is designed in a geometric model and optimized by LightTools Software, which enables the reflection of a wide-angle incident light beam into the single-point photodiode. The performance of home-made OSPD is characterized with working distances from 1 to 13 m and further analyzed utilizing developed a geometric model. The experimental and analytic results verify that our device is highly suitable for large-scale coordinate metrology. The developed device also holds great potential in various applications such as omnidirectional vision sensor, indoor global positioning system, and optical wireless communication systems.
Secure alignment of coordinate systems using quantum correlation
NASA Astrophysics Data System (ADS)
Rezazadeh, F.; Mani, A.; Karimipour, V.
2017-08-01
We show that two parties far apart can use shared entangled states and classical communication to align their coordinate systems with a very high fidelity. Moreover, compared with previous methods proposed for such a task, i.e., sending parallel or antiparallel pairs or groups of spin states, our method has the extra advantages of using single-qubit measurements and also being secure, so that third parties do not extract any information about the aligned coordinate system established between the two parties. The latter property is important in many other quantum information protocols in which measurements inevitably play a significant role.
Inertia Compensation While Scanning Screw Threads on Coordinate Measuring Machines
NASA Astrophysics Data System (ADS)
Kosarevsky, Sergey; Latypov, Viktor
2010-01-01
Usage of scanning coordinate-measuring machines for inspection of screw threads has become a common practice nowadays. Compared to touch trigger probing, scanning capabilities allow to speed up the measuring process while still maintaining high accuracy. However, in some cases accuracy drastically depends on the scanning speed. In this paper a compensation method is proposed allowing to reduce the influence of inertia of the probing system while scanning screw threads on coordinate-measuring machines.
Research on large spatial coordinate automatic measuring system based on multilateral method
NASA Astrophysics Data System (ADS)
Miao, Dongjing; Li, Jianshuan; Li, Lianfu; Jiang, Yuanlin; Kang, Yao; He, Mingzhao; Deng, Xiangrui
2015-10-01
To measure the spatial coordinate accurately and efficiently in large size range, a manipulator automatic measurement system which based on multilateral method is developed. This system is divided into two parts: The coordinate measurement subsystem is consists of four laser tracers, and the trajectory generation subsystem is composed by a manipulator and a rail. To ensure that there is no laser beam break during the measurement process, an optimization function is constructed by using the vectors between the laser tracers measuring center and the cat's eye reflector measuring center, then an orientation automatically adjust algorithm for the reflector is proposed, with this algorithm, the laser tracers are always been able to track the reflector during the entire measurement process. Finally, the proposed algorithm is validated by taking the calibration of laser tracker for instance: the actual experiment is conducted in 5m × 3m × 3.2m range, the algorithm is used to plan the orientations of the reflector corresponding to the given 24 points automatically. After improving orientations of some minority points with adverse angles, the final results are used to control the manipulator's motion. During the actual movement, there are no beam break occurs. The result shows that the proposed algorithm help the developed system to measure the spatial coordinates over a large range with efficiency.
NASA Astrophysics Data System (ADS)
Guo, Siyang; Lin, Jiarui; Yang, Linghui; Ren, Yongjie; Guo, Yin
2017-07-01
The workshop Measurement Position System (wMPS) is a distributed measurement system which is suitable for the large-scale metrology. However, there are some inevitable measurement problems in the shipbuilding industry, such as the restriction by obstacles and limited measurement range. To deal with these factors, this paper presents a method of reconstructing the spatial measurement network by mobile transmitter. A high-precision coordinate control network with more than six target points is established. The mobile measuring transmitter can be added into the measurement network using this coordinate control network with the spatial resection method. This method reconstructs the measurement network and broadens the measurement scope efficiently. To verify this method, two comparison experiments are designed with the laser tracker as the reference. The results demonstrate that the accuracy of point-to-point length is better than 0.4mm and the accuracy of coordinate measurement is better than 0.6mm.
Measurement of micro gears with a touch-trigger probe
NASA Astrophysics Data System (ADS)
Liu, YenChih; Chang, Kai-Hsiung; An, Nia-Chun; Yan, Sheng-Zhan; Tsai, Hsiu-An
2013-01-01
The measurement of micro gears with a touch-trigger probe will be introduced in this paper. Due to the small size and complex geometry of micro gears, it is difficult to measure them by traditional instruments like coordinate measuring machines (CMM) or laser displacement sensors. This study focuses on this topic and proposes an approach to measure the three dimensional profile of micro gears. The methodology is based on coordinate measurement. A special touch-trigger probe which detects the moment of contact is employed in the measuring system. The diameter of the probe tip is smaller than 2µm and therefore small enough for measuring micro structures. All the calibration and error compensation for the measuring system are discussed in the view of micro metrology. The comparison of measured profiles from both coordinate and image measurement is discussed. Results of experiments show that the proposed approach is worth of further development in the future.
NASA Astrophysics Data System (ADS)
Dong, Shuai; Yu, Shanshan; Huang, Zheng; Song, Shoutan; Shao, Xinxing; Kang, Xin; He, Xiaoyuan
2017-12-01
Multiple digital image correlation (DIC) systems can enlarge the measurement field without losing effective resolution in the area of interest (AOI). However, the results calculated in substereo DIC systems are located in its local coordinate system in most cases. To stitch the data obtained by each individual system, a data merging algorithm is presented in this paper for global measurement of multiple stereo DIC systems. A set of encoded targets is employed to assist the extrinsic calibration, of which the three-dimensional (3-D) coordinates are reconstructed via digital close range photogrammetry. Combining the 3-D targets with precalibrated intrinsic parameters of all cameras, the extrinsic calibration is significantly simplified. After calculating in substereo DIC systems, all data can be merged into a universal coordinate system based on the extrinsic calibration. Four stereo DIC systems are applied to a four point bending experiment of a steel reinforced concrete beam structure. Results demonstrate high accuracy for the displacement data merging in the overlapping field of views (FOVs) and show feasibility for the distributed FOVs measurement.
REQUEST: A Recursive QUEST Algorithm for Sequential Attitude Determination
NASA Technical Reports Server (NTRS)
Bar-Itzhack, Itzhack Y.
1996-01-01
In order to find the attitude of a spacecraft with respect to a reference coordinate system, vector measurements are taken. The vectors are pairs of measurements of the same generalized vector, taken in the spacecraft body coordinates, as well as in the reference coordinate system. We are interested in finding the best estimate of the transformation between these coordinate system.s The algorithm called QUEST yields that estimate where attitude is expressed by a quarternion. Quest is an efficient algorithm which provides a least squares fit of the quaternion of rotation to the vector measurements. Quest however, is a single time point (single frame) batch algorithm, thus measurements that were taken at previous time points are discarded. The algorithm presented in this work provides a recursive routine which considers all past measurements. The algorithm is based on on the fact that the, so called, K matrix, one of whose eigenvectors is the sought quaternion, is linerly related to the measured pairs, and on the ability to propagate K. The extraction of the appropriate eigenvector is done according to the classical QUEST algorithm. This stage, however, can be eliminated, and the computation simplified, if a standard eigenvalue-eigenvector solver algorithm is used. The development of the recursive algorithm is presented and illustrated via a numerical example.
Lublóy, Ágnes; Keresztúri, Judit Lilla; Benedek, Gábor
2017-10-01
Improving patient care coordination is critical for achieving better health outcome measures at reduced cost. However, assessing the results of patient care coordination at system level is lacking. In this report, based on administrative healthcare data, a provider-level care coordination measure is developed to assess the function of primary care at system level. In a sample of 31 070 patients with diabetes we find that the type of collaborative relationship general practitioners build up with specialists is associated with prescription drug costs. Regulating access to secondary care might result in cost savings through improved care coordination. © The Author 2017. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.
Field Mapping System for Solenoid Magnet
NASA Astrophysics Data System (ADS)
Park, K. H.; Jung, Y. K.; Kim, D. E.; Lee, H. G.; Park, S. J.; Chung, C. W.; Kang, B. K.
2007-01-01
A three-dimensional Hall probe mapping system for measuring the solenoid magnet of PLS photo-cathode RF e-gun has been developed. It can map the solenoid field either in Cartesian or in cylindrical coordinate system with a measurement reproducibility better than 5 × 10-5 T. The system has three axis motors: one for the azimuthal direction and the other two for the x and z direction. This architecture makes the measuring system simple in fabrication. The magnetic center was calculated using the measured axial component of magnetic field Bz in Cartesian coordinate system because the accuracy of magnetic axis measurement could be improved significantly by using Bz, instead of the radial component of magnetic field Br. This paper describes the measurement system and summarizes the measurement results for the solenoid magnetic of PLS photo-cathode RF e-gun.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cornwell, Paris A; Bunn, Jeffrey R; Schmidlin, Joshua E
The December 2010 version of the guide, ORNL/TM-2008/159, by Jeff Bunn, Josh Schmidlin, Camden Hubbard, and Paris Cornwell, has been further revised due to a major change in the GeoMagic Studio software for constructing a surface model. The Studio software update also includes a plug-in module to operate the FARO Scan Arm. Other revisions for clarity were also made. The purpose of this revision document is to guide the reader through the process of laser alignment used by NRSF2 at HFIR and VULCAN at SNS. This system was created to increase the spatial accuracy of the measurement points in amore » sample, reduce the use of neutron time used for alignment, improve experiment planning, and reduce operator error. The need for spatial resolution has been driven by the reduction in gauge volumes to the sub-millimeter level, steep strain gradients in some samples, and requests to mount multiple samples within a few days for relating data from each sample to a common sample coordinate system. The first step in this process involves mounting the sample on an indexer table in a laboratory set up for offline sample mounting and alignment in the same manner it would be mounted at either instrument. In the shared laboratory, a FARO ScanArm is used to measure the coordinates of points on the sample surface ('point cloud'), specific features and fiducial points. A Sample Coordinate System (SCS) needs to be established first. This is an advantage of the technique because the SCS can be defined in such a way to facilitate simple definition of measurement points within the sample. Next, samples are typically mounted to a frame of 80/20 and fiducial points are attached to the sample or frame then measured in the established sample coordinate system. The laser scan probe on the ScanArm can then be used to scan in an 'as-is' model of the sample as well as mounting hardware. GeoMagic Studio 12 is the software package used to construct the model from the point cloud the scan arm creates. Once a model, fiducial, and measurement files are created, a special program, called SScanSS combines the information and by simulation of the sample on the diffractometer can help plan the experiment before using neutron time. Finally, the sample is mounted on the relevant stress measurement instrument and the fiducial points are measured again. In the HFIR beam room, a laser tracker is used in conjunction with a program called CAM2 to measure the fiducial points in the NRSF2 instrument's sample positioner coordinate system. SScanSS is then used again to perform a coordinate system transformation of the measurement file locations to the sample positioner coordinate system. A procedure file is then written with the coordinates in the sample positioner coordinate system for the desired measurement locations. This file is often called a script or command file and can be further modified using excel. It is very important to note that this process is not a linear one, but rather, it often is iterative. Many of the steps in this guide are interdependent on one another. It is very important to discuss the process as it pertains to the specific sample being measured. What works with one sample may not necessarily work for another. This guide attempts to provide a typical work flow that has been successful in most cases.« less
Coordinate transformations and gauges in the relativistic astronomical reference systems
NASA Astrophysics Data System (ADS)
Tao, J.-H.; Huang, T.-Y.; Han, C.-H.
2000-11-01
This paper applies a fully post-Newtonian theory (Damour et al. 1991, 1992, 1993, 1994) to the problem of gauge in relativistic reference systems. Gauge fixing is necessary when the precision of time measurement and application reaches 10-16 or better. We give a general procedure for fixing the gauges of gravitational potentials in both the global and local coordinate systems, and for determining the gauge functions in all the coordinate transformations. We demonstrate that gauge fixing in a gravitational N-body problem can be solved by fixing the gauge of the self-gravitational potential of each body and the gauge function in the coordinate transformation between the global and local coordinate systems. We also show that these gauge functions can be chosen to make all the coordinate systems harmonic or any as required, no matter what gauge is chosen for the self-gravitational potential of each body.
Positioning sensor by combining optical projection and photogrammetry
NASA Astrophysics Data System (ADS)
Zheng, Benrui
Six spatial parameters, (x, y, z) for translation, and pitch, roll, and yaw for rotation, are used to describe the 3-dimensional position and orientation of a rigid body---the 6 degrees of freedom (DOF). The ability to measure these parameters is required in a diverse range of applications including machine tool metrology, robot calibration, motion control, motion analysis, and reconstructive surgery. However, there are limitations associated with the currently available measurement systems. Shortcomings include some of the following: short dynamic range, limited accuracy, line of sight restrictions, and capital cost. The objective of this dissertation was to develop a new metrology system that overcomes line of sight restrictions, reduces system costs, allows large dynamic range and has the potential to provide high measurement accuracy. The new metrology system proposed in this dissertation is based on a combination of photogrammetry and optical pattern projection. This system has the potential to enable real-time measurement of a small lightweight module's location. The module generates an optical pattern that is observable on the surrounding walls, and photogrammetry is used to measure the absolute coordinates of features in the projected optical pattern with respect to a defined global coordinate system. By combining these absolute coordinates with the known angular information of the optical projection beams, a minimization algorithm can be used to extract the absolute coordinates and angular orientation of the module itself. The feasibility of the proposed metrology system was first proved through preliminary experimental tests. By using a module with a 7x7 dot matrix pattern, experimental agreement of 1 to 5 parts in 103 was obtained by translating the module over 0.9 m and by rotating it through 60°. The proposed metrology system was modeled through numerical simulations and factors affecting the uncertainty of the measurement were investigated. The simulation results demonstrate that optimum design of the projected pattern gives a lower associated measurement uncertainty than is possible by direct photogrammetric measurement with traditional tie points alone. Based on the simulation results, a few improvements have been made to the proposed metrology systems. These improvements include using a module with larger full view angle and larger number of dots, performing angle calibration for the module, using a virtual camera approach to determine the module location and employing multiple coordinates system for large range rotation measurement. With the new proposed virtual camera approach, experimental agreement at the level of 3 parts in 104 was observed for the one dimension translation test. The virtual camera approach is faster than the algorithm and an additional minimization analysis is no longer needed. In addition, the virtual camera approach offers an additional benefit that it is no longer necessary to identify all dots in the pattern and so is more amenable to use in realistic and usually complicated environments. A preliminary rotation test over 120° was conducted by tying three coordinate systems together. It was observed that the absolute values of the angle differences between the measured angle and the encoder reading are smaller than 0.23° for all measurements. It is found that this proposed metrology system has the ability to measure larger angle range (up to 360°) by using multiple coordinate systems. The uncertainty analysis of the proposed system was performed through Monte Carlo simulation and it was demonstrated that the experimental results are consistent with the analysis.
Position feedback control system
Bieg, Lothar F.; Jokiel, Jr., Bernhard; Ensz, Mark T.; Watson, Robert D.
2003-01-01
Disclosed is a system and method for independently evaluating the spatial positional performance of a machine having a movable member, comprising an articulated coordinate measuring machine comprising: a first revolute joint; a probe arm, having a proximal end rigidly attached to the first joint, and having a distal end with a probe tip attached thereto, wherein the probe tip is pivotally mounted to the movable machine member; a second revolute joint; a first support arm serially connecting the first joint to the second joint; and coordinate processing means, operatively connected to the first and second revolute joints, for calculating the spatial coordinates of the probe tip; means for kinematically constraining the articulated coordinate measuring machine to a working surface; and comparator means, in operative association with the coordinate processing means and with the movable machine, for comparing the true position of the movable machine member, as measured by the true position of the probe tip, with the desired position of the movable machine member.
NASA Astrophysics Data System (ADS)
Mi, Yuhe; Huang, Yifan; Li, Lin
2015-08-01
Based on the location technique of beacon photogrammetry, Dual Camera Photogrammetry (DCP) algorithm was used to assist helicopters landing on the ship. In this paper, ZEMAX was used to simulate the two Charge Coupled Device (CCD) cameras imaging four beacons on both sides of the helicopter and output the image to MATLAB. Target coordinate systems, image pixel coordinate systems, world coordinate systems and camera coordinate systems were established respectively. According to the ideal pin-hole imaging model, the rotation matrix and translation vector of the target coordinate systems and the camera coordinate systems could be obtained by using MATLAB to process the image information and calculate the linear equations. On the basis mentioned above, ambient temperature and the positions of the beacons and cameras were changed in ZEMAX to test the accuracy of the DCP algorithm in complex sea status. The numerical simulation shows that in complex sea status, the position measurement accuracy can meet the requirements of the project.
Alignment of angular velocity sensors for a vestibular prosthesis.
Digiovanna, Jack; Carpaneto, Jacopo; Micera, Silvestro; Merfeld, Daniel M
2012-02-13
Vestibular prosthetics transmit angular velocities to the nervous system via electrical stimulation. Head-fixed gyroscopes measure angular motion, but the gyroscope coordinate system will not be coincident with the sensory organs the prosthetic replaces. Here we show a simple calibration method to align gyroscope measurements with the anatomical coordinate system. We benchmarked the method with simulated movements and obtain proof-of-concept with one healthy subject. The method was robust to misalignment, required little data, and minimal processing.
The guidance methodology of a new automatic guided laser theodolite system
NASA Astrophysics Data System (ADS)
Zhang, Zili; Zhu, Jigui; Zhou, Hu; Ye, Shenghua
2008-12-01
Spatial coordinate measurement systems such as theodolites, laser trackers and total stations have wide application in manufacturing and certification processes. The traditional operation of theodolites is manual and time-consuming which does not meet the need of online industrial measurement, also laser trackers and total stations need reflective targets which can not realize noncontact and automatic measurement. A new automatic guided laser theodolite system is presented to achieve automatic and noncontact measurement with high precision and efficiency which is comprised of two sub-systems: the basic measurement system and the control and guidance system. The former system is formed by two laser motorized theodolites to accomplish the fundamental measurement tasks while the latter one consists of a camera and vision system unit mounted on a mechanical displacement unit to provide azimuth information of the measured points. The mechanical displacement unit can rotate horizontally and vertically to direct the camera to the desired orientation so that the camera can scan every measured point in the measuring field, then the azimuth of the corresponding point is calculated for the laser motorized theodolites to move accordingly to aim at it. In this paper the whole system composition and measuring principle are analyzed, and then the emphasis is laid on the guidance methodology for the laser points from the theodolites to move towards the measured points. The guidance process is implemented based on the coordinate transformation between the basic measurement system and the control and guidance system. With the view field angle of the vision system unit and the world coordinate of the control and guidance system through coordinate transformation, the azimuth information of the measurement area that the camera points at can be attained. The momentary horizontal and vertical changes of the mechanical displacement movement are also considered and calculated to provide real time azimuth information of the pointed measurement area by which the motorized theodolite will move accordingly. This methodology realizes the predetermined location of the laser points which is within the camera-pointed scope so that it accelerates the measuring process and implements the approximate guidance instead of manual operations. The simulation results show that the proposed method of automatic guidance is effective and feasible which provides good tracking performance of the predetermined location of laser points.
NASA Astrophysics Data System (ADS)
Avanesov, G. A.; Bessonov, R. V.; Kurkina, A. N.; Nikitin, A. V.; Sazonov, V. V.
2018-01-01
The BOKZ-M60 star sensor (Unit for Measuring Star Coordinates) is intended for determining the parameters of the orientation of the axes of the intrinsic coordinate system relative to the axes of the inertial system by observations of the regions of the stellar sky. It is convenient to characterize an error of the single determination of the orientation of the intrinsic coordinate system of the sensor by the vector of an infinitesimal turn of this system relative to its found position. Full-scale ground-based tests have shown that, for a resting sensor the root-mean-square values of the components of this vector along the axes of the intrinsic coordinate system lying in the plane of the sensor CCD matrix are less than 2″ and the component along the axis perpendicular to the matrix plane is characterized by the root-mean-square value of 15″. The joint processing of one-stage readings of several sensors installed on the same platform allows us to improve the indicated accuracy characteristics. In this paper, estimates of the accuracy of systems from BOKZ-M60 with two and four sensors performed from measurements carried out during the normal operation of these sensors on the Resurs-P satellite are given. Processing the measurements of the sensor system allowed us to increase the accuracy of determining the each of their orientations and to study random and systematic errors in these measurements.
Compensation for positioning error of industrial robot for flexible vision measuring system
NASA Astrophysics Data System (ADS)
Guo, Lei; Liang, Yajun; Song, Jincheng; Sun, Zengyu; Zhu, Jigui
2013-01-01
Positioning error of robot is a main factor of accuracy of flexible coordinate measuring system which consists of universal industrial robot and visual sensor. Present compensation methods for positioning error based on kinematic model of robot have a significant limitation that it isn't effective in the whole measuring space. A new compensation method for positioning error of robot based on vision measuring technique is presented. One approach is setting global control points in measured field and attaching an orientation camera to vision sensor. Then global control points are measured by orientation camera to calculate the transformation relation from the current position of sensor system to global coordinate system and positioning error of robot is compensated. Another approach is setting control points on vision sensor and two large field cameras behind the sensor. Then the three dimensional coordinates of control points are measured and the pose and position of sensor is calculated real-timely. Experiment result shows the RMS of spatial positioning is 3.422mm by single camera and 0.031mm by dual cameras. Conclusion is arithmetic of single camera method needs to be improved for higher accuracy and accuracy of dual cameras method is applicable.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gladstone, D. J.; Li, S.; Jarvis, L. A.
2011-07-15
Purpose: The authors hereby notify the Radiation Oncology community of a potentially lethal error due to improper implementation of linear units of measure in a treatment planning system. The authors report an incident in which a patient was nearly mistreated during a stereotactic radiotherapy procedure due to inappropriate reporting of stereotactic coordinates by the radiation therapy treatment planning system in units of centimeter rather than in millimeter. The authors suggest a method to detect such errors during treatment planning so they are caught and corrected prior to the patient positioning for treatment on the treatment machine. Methods: Using pretreatment imaging,more » the authors found that stereotactic coordinates are reported with improper linear units by a treatment planning system. The authors have implemented a redundant, independent method of stereotactic coordinate calculation. Results: Implementation of a double check of stereotactic coordinates via redundant, independent calculation is simple and accurate. Use of this technique will avoid any future error in stereotactic treatment coordinates due to improper linear units, transcription, or other similar errors. Conclusions: The authors recommend an independent double check of stereotactic treatment coordinates during the treatment planning process in order to avoid potential mistreatment of patients.« less
Multiple Coordination Patterns in Infant and Adult Vocalizations
Abney, Drew H.; Warlaumont, Anne S.; Oller, D. Kimbrough; Wallot, Sebastian; Kello, Christopher T.
2017-01-01
The study of vocal coordination between infants and adults has led to important insights into the development of social, cognitive, emotional and linguistic abilities. We used an automatic system to identify vocalizations produced by infants and adults over the course of the day for fifteen infants studied longitudinally during the first two years of life. We measured three different types of vocal coordination: coincidence-based, rate-based, and cluster-based. Coincidence-based and rate-based coordination are established measures in the developmental literature. Cluster-based coordination is new and measures the strength of matching in the degree to which vocalization events occur in hierarchically nested clusters. We investigated whether various coordination patterns differ as a function of vocalization type, whether different coordination patterns provide unique information about the dynamics of vocal interaction, and how the various coordination patterns each relate to infant age. All vocal coordination patterns displayed greater coordination for infant speech-related vocalizations, adults adapted the hierarchical clustering of their vocalizations to match that of infants, and each of the three coordination patterns had unique associations with infant age. Altogether, our results indicate that vocal coordination between infants and adults is multifaceted, suggesting a complex relationship between vocal coordination and the development of vocal communication. PMID:29375276
Franck, J.V.; Broadhead, P.S.; Skiff, E.W.
1959-07-14
A semiautomatic measuring projector particularly adapted for measurement of the coordinates of photographic images of particle tracks as prcduced in a bubble or cloud chamber is presented. A viewing screen aids the operator in selecting a particle track for measurement. After approximate manual alignment, an image scanning system coupled to a servo control provides automatic exact alignment of a track image with a reference point. The apparatus can follow along a track with a continuous motion while recording coordinate data at various selected points along the track. The coordinate data is recorded on punched cards for subsequent computer calculation of particle trajectory, momentum, etc.
Correlation between three color coordinates of human teeth.
Lee, Yong-Keun
2014-11-01
The objective was to determine whether there were significant correlations in the three color coordinates within each of two color coordinate systems, such as the Commission Internationale de l’Eclairage (CIE) L*a*b* system, and the lightness, chroma, and hue angle system, of human vital teeth. The color of six maxillary and six mandibular anterior teeth was measured by the Shade Vision System. Pearson correlations between each pair of the color coordinates were determined (α=0.01 ). The influence of two color coordinates on the other color coordinate was determined with a multiple regression analysis (α=0.01 ). Based on correlation analyses, all the color coordinate pairs showed significant correlations except for the chroma and hue angle pair. The CIE L* was negatively correlated with the CIE a*,b*, and chroma, but positively correlated with the hue angle. The CIE a* was positively correlated with the CIE b* and chroma. Tooth color coordinates were correlated each other. Lighter teeth were less chromatic both in the CIE a* and b* coordinates. Therefore, it was postulated that the three color coordinates of human teeth were harmonized within certain color attribute ranges, and a lack of correlations in these coordinates might indicate external/internal discolorations and/or anomalies of teeth.
Correlation between three color coordinates of human teeth
NASA Astrophysics Data System (ADS)
Lee, Yong-Keun
2014-11-01
The objective was to determine whether there were significant correlations in the three color coordinates within each of two color coordinate systems, such as the Commission Internationale de l'Eclairage (CIE) L*a*b* system, and the lightness, chroma, and hue angle system, of human vital teeth. The color of six maxillary and six mandibular anterior teeth was measured by the Shade Vision System. Pearson correlations between each pair of the color coordinates were determined (α=0.01). The influence of two color coordinates on the other color coordinate was determined with a multiple regression analysis (α=0.01). Based on correlation analyses, all the color coordinate pairs showed significant correlations except for the chroma and hue angle pair. The CIE L* was negatively correlated with the CIE a*, b*, and chroma, but positively correlated with the hue angle. The CIE a* was positively correlated with the CIE b* and chroma. Tooth color coordinates were correlated each other. Lighter teeth were less chromatic both in the CIE a* and b* coordinates. Therefore, it was postulated that the three color coordinates of human teeth were harmonized within certain color attribute ranges, and a lack of correlations in these coordinates might indicate external/internal discolorations and/or anomalies of teeth.
Precise Selenodetic Coordinate System on Artificial Light Refers
NASA Astrophysics Data System (ADS)
Bagrov, Alexander; Pichkhadze, Konstantin M.; Sysoev, Valentin
Historically a coordinate system for the Moon was established on the base of telescopic observations from the Earth. As the angular resolution of Earth-to-Space telescopic observations is limited by Earth atmosphere, and is ordinary worse then 1 ang. second, the mean accuracy of selenodetic coordinates is some angular minutes, which corresponds to errors about 900 meters for positions of lunar objects near center of visible lunar disk, and at least twice more when objects are near lunar poles. As there are no Global Positioning System nor any astronomical observation instruments on the Moon, we proposed to use an autonomous light beacon on the Luna-Globe landing module to fix its position on the surface of the moon ant to use it as refer point for fixation of spherical coordinates system for the Moon. The light beacon is designed to be surely visible by orbiting probe TV-camera. As any space probe has its own stars-orientation system, there is not a problem to calculate a set of directions to the beacon and to the referent stars in probe-centered coordinate system during flight over the beacon. Large number of measured angular positions and time of each observation will be enough to calculate both orbital parameters of the probe and selenodetic coordinates of the beacon by methods of geodesy. All this will allow fixing angular coordinates of any feature of lunar surface in one global coordinate system, referred to the beacon. The satellite’s orbit plane contains ever the center mass of main body, so if the beacon will be placed closely to a lunar pole, we shall determine pole point position of the Moon with accuracy tens times better then it is known now. When angular accuracy of self-orientation by stars of the orbital module of Luna-Glob mission will be 6 angular seconds, then being in circular orbit with height of 200 km the on-board TV-camera will allow calculation of the beacon position as well as 6" corresponding to spatial resolution of the camera. It mean that coordinates of the beacon will be determined with accuracy not worse then 6 meters on the lunar surface. Much more accuracy can be achieved if orbital probe will use as precise angular measurer as optical interferometer. The limiting accuracy of proposed method is far above any reasonable level, because it may be sub-millimeter one. Theoretical analysis shows that for achievement of 1-meter accuracy of coordinate measuring over lunar globe it will be enough to disperse over it surface some 60 light beacons. Designed by Lavochkin Association light beacon is autonomous one, and it will work at least 10 years, so coordinate frame of any other lunar mission could use established selenodetic coordinates during this period. The same approach may be used for establishing Martial coordinates system.
Upper Limb Coordination in Individuals With Stroke: Poorly Defined and Poorly Quantified.
Tomita, Yosuke; Rodrigues, Marcos R M; Levin, Mindy F
2017-01-01
The identification of deficits in interjoint coordination is important in order to better focus upper limb rehabilitative treatment after stroke. The majority of standardized clinical measures characterize endpoint performance, such as accuracy, speed, and smoothness, based on the assumption that endpoint performance reflects interjoint coordination, without measuring the underlying temporal and spatial sequences of joint recruitment directly. However, this assumption is questioned since improvements of endpoint performance can be achieved through different degrees of restitution or compensation of upper limb motor impairments based on the available kinematic redundancy of the system. Confusion about adequate measurement may stem from a lack a definition of interjoint coordination during reaching. We suggest an operational definition of interjoint coordination during reaching as a goal-oriented process in which joint degrees of freedom are organized in both spatial and temporal domains such that the endpoint reaches a desired location in a context-dependent manner. In this point-of-view article, we consider how current approaches to laboratory and clinical measures of coordination comply with our definition. We propose future study directions and specific research strategies to develop clinical measures of interjoint coordination with better construct and content validity than those currently in use.
The Unifying Principle of Coordinated Measurements in Geospace Science
NASA Astrophysics Data System (ADS)
Lotko, William
2017-04-01
Space scientists recognize geospace as a coupled dynamical system extending from the Earth's upper atmosphere, ionosphere, and magnetosphere, through interplanetary space to the Sun. The weather in geospace describes variability in the electromagnetic fields, particle radiation, plasmas, and gases permeating it, usually in response to solar disturbances. Severe space weather poses a significant threat to human activities in space and to modern technological systems deployed both in space and at Earth. The challenge of characterizing and predicting space weather requires widely distributed, coordinated observations. Partnerships among government agencies, international consortia, and the private sector are developing creative solutions to address this challenge. This brief commentary highlights some of the coordinated measurements and data systems that are unifying knowledge of the geospace environment.
Xie, Mingxia; Wang, Jiayao; Chen, Ke
2017-01-01
This study investigates the basic characteristics and proposes a concept for the complex system of geographical conditions (CSGC). By analyzing the DPSIR model and its correlation with the index system, we selected indexes for geographical conditions according to the resources, ecology, environment, economy and society parameters to build a system. This system consists of four hierarchies: index, classification, element and target levels. We evaluated the elements or indexes of the complex system using the TOPSIS method and a general model coordinating multiple complex systems. On this basis, the coordination analysis experiment of geographical conditions is applied to cities in the Henan province in China. The following conclusions were reached: ①According to the pressure, state and impact of geographical conditions, relatively consistent measures are taken around the city, but with conflicting results. ②The coordination degree of geographical conditions is small among regions showing large differences in classification index value. The degree of coordination of such regions is prone to extreme values; however, the smaller the difference the larger the coordination degree. ③The coordinated development of geographical conditions in the Henan province is at the stage of the point axis.
A method for remote sounding of a bottom relief of water objects with using GPS
NASA Astrophysics Data System (ADS)
Mamontova, L. S.
2014-12-01
The no-fly automated system of small rivers' depth's measurement which is based on a combination of a differential method GPS-definition of the pro-measured vessel's coordinates both the method of depth's measurement with sonic depth finder and the method of the vessel's management was examined in this article.On the central station the digital card with a relief for a pro-measured zone of the reservoir is formed and the position of a pro-measured vessel on the tacks is controlled thanks to the coordinates of a pro-measured vessel and depth's measurements with sonic depth finder.The offered system allows to raise the level of depth's pro-measured works.
Specimen coordinate automated measuring machine/fiducial automated measuring machine
Hedglen, Robert E.; Jacket, Howard S.; Schwartz, Allan I.
1991-01-01
The Specimen coordinate Automated Measuring Machine (SCAMM) and the Fiducial Automated Measuring Machine (FAMM) is a computer controlled metrology system capable of measuring length, width, and thickness, and of locating fiducial marks. SCAMM and FAMM have many similarities in their designs, and they can be converted from one to the other without taking them out of the hot cell. Both have means for: supporting a plurality of samples and a standard; controlling the movement of the samples in the +/- X and Y directions; determining the coordinates of the sample; compensating for temperature effects; and verifying the accuracy of the measurements and repeating as necessary. SCAMM and FAMM are designed to be used in hot cells.
Phase difference of arrival geolocation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mason, John J.; Romero, Louis
2017-05-16
Geolocation is performed by receiving, at a plurality of non-earthbound platforms each moving in a known manner within a spatial coordinate system, a radio frequency (RF) signal transmitted from a transmitter at an unknown location on earth within the spatial coordinate system. For each of the platforms, a phase change of the received frequency carrier is measured over the same duration of time. The measured phase changes are combined to determine the transmitter location.
Coordinate metrology using scanning probe microscopes
NASA Astrophysics Data System (ADS)
Marinello, F.; Savio, E.; Bariani, P.; Carmignato, S.
2009-08-01
New positioning, probing and measuring strategies in coordinate metrology are needed for the accomplishment of true three-dimensional characterization of microstructures, with uncertainties in the nanometre range. In the present work, the implementation of scanning probe microscopes (SPMs) as systems for coordinate metrology is discussed. A new non-raster measurement approach is proposed, where the probe is moved to sense points along free paths on the sample surface, with no loss of accuracy with respect to traditional raster scanning and scan time reduction. Furthermore, new probes featuring long tips with innovative geometries suitable for coordinate metrology through SPMs are examined and reported.
Techniques for Generating Objects in a Three-Dimensional CAD System.
ERIC Educational Resources Information Center
Goss, Larry D.
1987-01-01
Discusses coordinate systems, units of measure, scaling and levels as they relate to a database generated by a computer in a spatial rather than planer location. Describes geometric-oriented input, direct coordinates, transformations, annotation, editing and patterns. Stresses that hand drafting emulation is a short-sighted approach to…
Xu, Guan; Yuan, Jing; Li, Xiaotao; Su, Jian
2017-08-01
Vision measurement on the basis of structured light plays a significant role in the optical inspection research. The 2D target fixed with a line laser projector is designed to realize the transformations among the world coordinate system, the camera coordinate system and the image coordinate system. The laser projective point and five non-collinear points that are randomly selected from the target are adopted to construct a projection invariant. The closed form solutions of the 3D laser points are solved by the homogeneous linear equations generated from the projection invariants. The optimization function is created by the parameterized re-projection errors of the laser points and the target points in the image coordinate system. Furthermore, the nonlinear optimization solutions of the world coordinates of the projection points, the camera parameters and the lens distortion coefficients are contributed by minimizing the optimization function. The accuracy of the 3D reconstruction is evaluated by comparing the displacements of the reconstructed laser points with the actual displacements. The effects of the image quantity, the lens distortion and the noises are investigated in the experiments, which demonstrate that the reconstruction approach is effective to contribute the accurate test in the measurement system.
Measurement of whole tire profile
NASA Astrophysics Data System (ADS)
Yang, Yongyue; Jiao, Wenguang
2010-08-01
In this paper, a precision measuring device is developed for obtaining characteristic curve of tire profile and its geometric parameters. It consists of a laser displacement measurement unit, a closed-loop precision two-dimensional coordinate table, a step motor control system and a fast data acquisition and analysis system. Based on the laser trigonometry, a data map of tire profile and coordinate values of all points can be obtained through corresponding data transformation. This device has a compact structure, a convenient control, a simple hardware circuit design and a high measurement precision. Experimental results indicate that measurement precision can meet the customer accuracy requirement of +/-0.02 mm.
Video-Camera-Based Position-Measuring System
NASA Technical Reports Server (NTRS)
Lane, John; Immer, Christopher; Brink, Jeffrey; Youngquist, Robert
2005-01-01
A prototype optoelectronic system measures the three-dimensional relative coordinates of objects of interest or of targets affixed to objects of interest in a workspace. The system includes a charge-coupled-device video camera mounted in a known position and orientation in the workspace, a frame grabber, and a personal computer running image-data-processing software. Relative to conventional optical surveying equipment, this system can be built and operated at much lower cost; however, it is less accurate. It is also much easier to operate than are conventional instrumentation systems. In addition, there is no need to establish a coordinate system through cooperative action by a team of surveyors. The system operates in real time at around 30 frames per second (limited mostly by the frame rate of the camera). It continuously tracks targets as long as they remain in the field of the camera. In this respect, it emulates more expensive, elaborate laser tracking equipment that costs of the order of 100 times as much. Unlike laser tracking equipment, this system does not pose a hazard of laser exposure. Images acquired by the camera are digitized and processed to extract all valid targets in the field of view. The three-dimensional coordinates (x, y, and z) of each target are computed from the pixel coordinates of the targets in the images to accuracy of the order of millimeters over distances of the orders of meters. The system was originally intended specifically for real-time position measurement of payload transfers from payload canisters into the payload bay of the Space Shuttle Orbiters (see Figure 1). The system may be easily adapted to other applications that involve similar coordinate-measuring requirements. Examples of such applications include manufacturing, construction, preliminary approximate land surveying, and aerial surveying. For some applications with rectangular symmetry, it is feasible and desirable to attach a target composed of black and white squares to an object of interest (see Figure 2). For other situations, where circular symmetry is more desirable, circular targets also can be created. Such a target can readily be generated and modified by use of commercially available software and printed by use of a standard office printer. All three relative coordinates (x, y, and z) of each target can be determined by processing the video image of the target. Because of the unique design of corresponding image-processing filters and targets, the vision-based position- measurement system is extremely robust and tolerant of widely varying fields of view, lighting conditions, and varying background imagery.
NASA Technical Reports Server (NTRS)
Malla, R. P.; Wu, S.-C.; Lichten, S. M.
1993-01-01
Geocentric tracking station coordinates and short-period Earth-orientation variations can be measured with Global Positioning System (GPS) measurements. Unless calibrated, geocentric coordinate errors and changes in Earth orientation can lead to significant deep-space tracking errors. Ground-based GPS estimates of daily and subdaily changes in Earth orientation presently show centimeter-level precision. Comparison between GPS-estimated Earth-rotation variations, which are the differences between Universal Time 1 and Universal Coordinated Time (UT1-UTC), and those calculated from ocean tide models suggests that observed subdaily variations in Earth rotation are dominated by oceanic tidal effects. Preliminary GPS estimates for the geocenter location (from a 3-week experiment) agree with independent satellite laser-ranging estimates to better than 10 cm. Covariance analysis predicts that temporal resolution of GPS estimates for Earth orientation and geocenter improves significantly when data collected from low Earth-orbiting satellites as well as from ground sites are combined. The low Earth GPS tracking data enhance the accuracy and resolution for measuring high-frequency global geodynamical signals over time scales of less than 1 day.
Guo, Yue-Ting; Xu, Jian-Gang
2013-05-01
Based on the statistical data of urbanization and eco-environment of 35 cities in the Huaihe River Basin of China in 2010, an index system of urbanization-eco-environment system was established by using fuzzy matter element theory, and the weight of each indicator was calculated by entropy method. The improved function of the coupling coordination degree of urbanization and eco-environment was constructed to measure this coupling coordination degree in the Huaihe River Basin. In 2010, the development level of urbanization subsystem in the Basin was lower than that of the eco-environment subsystem, and the integrated coordination index of urbanization and eco-environment was 0.186, indicating that there was a gap between the two types of indicators. The average coupling degree of urbanization and eco-environment was 0.475, indicating that the urbanization-eco-environment system was at antagonistic stage. There was a greater difference in the development level of urbanization subsystem, but a smaller difference in the development level of eco-environment subsystem among the cities. The average value of the coordination degree of all the cities was 0.706, indicating that the Huaihe River Basin was at high coordination coupling stage, and the integrated coherence and synergistic effect of urbanization and eco-environment construction in the Huaihe River Basin was higher.
Videogrammetric Model Deformation Measurement System User's Manual
NASA Technical Reports Server (NTRS)
Dismond, Harriett R.
2002-01-01
The purpose of this manual is to provide the user of the NASA VMD system, running the MDef software, Version 1.10, all information required to operate the system. The NASA Videogrammetric Model Deformation system consists of an automated videogrammetric technique used to measure the change in wing twist and bending under aerodynamic load in a wind tunnel. The basic instrumentation consists of a single CCD video camera and a frame grabber interfaced to a computer. The technique is based upon a single view photogrammetric determination of two-dimensional coordinates of wing targets with fixed (and known) third dimensional coordinate, namely the span-wise location. The major consideration in the development of the measurement system was that productivity must not be appreciably reduced.
Rail inspection system based on iGPS
NASA Astrophysics Data System (ADS)
Fu, Xiaoyan; Wang, Mulan; Wen, Xiuping
2018-05-01
Track parameters include gauge, super elevation, cross level and so on, which could be calculated through the three-dimensional coordinates of the track. The rail inspection system based on iGPS (indoor/infrared GPS) was composed of base station, receiver, rail inspection frame, wireless communication unit, display and control unit and data processing unit. With the continuous movement of the inspection frame, the system could accurately inspect the coordinates of rail; realize the intelligent detection and precision measurement. According to principle of angle intersection measurement, the inspection model was structured, and detection process was given.
Liu, Hesen; Zhu, Lin; Pan, Zhuohong; ...
2015-09-14
One of the main drawbacks of the existing oscillation damping controllers that are designed based on offline dynamic models is adaptivity to the power system operating condition. With the increasing availability of wide-area measurements and the rapid development of system identification techniques, it is possible to identify a measurement-based transfer function model online that can be used to tune the oscillation damping controller. Such a model could capture all dominant oscillation modes for adaptive and coordinated oscillation damping control. our paper describes a comprehensive approach to identify a low-order transfer function model of a power system using a multi-input multi-outputmore » (MIMO) autoregressive moving average exogenous (ARMAX) model. This methodology consists of five steps: 1) input selection; 2) output selection; 3) identification trigger; 4) model estimation; and 5) model validation. The proposed method is validated by using ambient data and ring-down data in the 16-machine 68-bus Northeast Power Coordinating Council system. Our results demonstrate that the measurement-based model using MIMO ARMAX can capture all the dominant oscillation modes. Compared with the MIMO subspace state space model, the MIMO ARMAX model has equivalent accuracy but lower order and improved computational efficiency. The proposed model can be applied for adaptive and coordinated oscillation damping control.« less
NASA Astrophysics Data System (ADS)
Andrae, Peter; Beeck, Manfred-Andreas; Jueptner, Werner P. O.; Nadeborn, Werner; Osten, Wolfgang
1996-09-01
Holographic interferometry makes it possible to measure high precision displacement data in the range of the wavelength of the used laser light. However, the determination of 3D- displacement vectors of objects with complex surfaces requires the measurement of 3D-object coordinates not only to consider local sensitivities but to distinguish between in-plane deformation, i.e. strains, and out-of-plane components, i.e. shears, too. To this purpose both the surface displacement and coordinates have to be combined and it is advantageous to make the data available for CAE- systems. The object surface has to be approximated analytically from the measured point cloud to generate a surface mesh. The displacement vectors can be assigned to the nodes of this surface mesh for visualization of the deformation of the object under test. They also can be compared to the results of FEM-calculations or can be used as boundary conditions for further numerical investigations. Here the 3D-object coordinates are measured in a separate topometric set-up using a modified fringe projection technique to acquire absolute phase values and a sophisticated geometrical model to map these phase data onto coordinates precisely. The determination of 3D-displacement vectors requires the measurement of several interference phase distributions for at least three independent sensitivity directions depending on the observation and illumination directions as well as the 3D-position of each measuring point. These geometric quantities have to be transformed into a reference coordinate system of the interferometric set-up in order to calculate the geometric matrix. The necessary transformation can be realized by means of a detection of object features in both data sets and a subsequent determination of the external camera orientation. This paper presents a consistent solution for the measurement and combination of shape and displacement data including their transformation into simulation systems. The described procedure will be demonstrated on an automotive component. Thus more accurate and effective measurement techniques make it possible to bring experimental and numerical displacement analysis closer.
Integrated fringe projection 3D scanning system for large-scale metrology based on laser tracker
NASA Astrophysics Data System (ADS)
Du, Hui; Chen, Xiaobo; Zhou, Dan; Guo, Gen; Xi, Juntong
2017-10-01
Large scale components exist widely in advance manufacturing industry,3D profilometry plays a pivotal role for the quality control. This paper proposes a flexible, robust large-scale 3D scanning system by integrating a robot with a binocular structured light scanner and a laser tracker. The measurement principle and system construction of the integrated system are introduced. And a mathematical model is established for the global data fusion. Subsequently, a flexible and robust method and mechanism is introduced for the establishment of the end coordination system. Based on this method, a virtual robot noumenon is constructed for hand-eye calibration. And then the transformation matrix between end coordination system and world coordination system is solved. Validation experiment is implemented for verifying the proposed algorithms. Firstly, hand-eye transformation matrix is solved. Then a car body rear is measured for 16 times for the global data fusion algorithm verification. And the 3D shape of the rear is reconstructed successfully.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schiefer, H., E-mail: johann.schiefer@kssg.ch; Peters, S.; Plasswilm, L.
Purpose: For stereotactic radiosurgery, the AAPM Report No. 54 [AAPM Task Group 42 (AAPM, 1995)] requires the overall stability of the isocenter (couch, gantry, and collimator) to be within a 1 mm radius. In reality, a rotating system has no rigid axis and thus no isocenter point which is fixed in space. As a consequence, the isocenter concept is reviewed here. It is the aim to develop a measurement method following the revised definitions. Methods: The mechanical isocenter is defined here by the point which rotates on the shortest path in the room coordinate system. The path is labeled asmore » “isocenter path.” Its center of gravity is assumed to be the mechanical isocenter. Following this definition, an image-based and radiation-free measurement method was developed. Multiple marker pairs in a plane perpendicular to the assumed gantry rotation axis of a linear accelerator are imaged with a smartphone application from several rotation angles. Each marker pair represents an independent measuring system. The room coordinates of the isocenter path and the mechanical isocenter are calculated based on the marker coordinates. The presented measurement method is by this means strictly focused on the mechanical isocenter. Results: The measurement result is available virtually immediately following completion of measurement. When 12 independent measurement systems are evaluated, the standard deviations of the isocenter path points and mechanical isocenter coordinates are 0.02 and 0.002 mm, respectively. Conclusions: The measurement is highly accurate, time efficient, and simple to adapt. It is therefore suitable for regular checks of the mechanical isocenter characteristics of the gantry and collimator rotation axis. When the isocenter path is reproducible and its extent is in the range of the needed geometrical accuracy, it should be taken into account in the planning process. This is especially true for stereotactic treatments and radiosurgery.« less
Deriving a geocentric reference frame for satellite positioning and navigation
NASA Technical Reports Server (NTRS)
Malla, R. P.; Wu, S.-C.
1988-01-01
With the advent of Earth-orbiting geodetic satellites, nongeocentric datums or reference frames have become things of the past. Accurate geocentric three-dimensional positioning is now possible and is of great importance for various geodetic and oceanographic applications. While relative positioning accuracy of a few centimeters has become a reality using very long baseline interferometry (VLBI), the uncertainty in the offset of the adopted coordinate system origin from the geocenter is still believed to be on the order of 1 meter. Satellite laser ranging (SLR), however, is capable of determining this offset to better than 10 cm, but this is possible only after years of measurements. Global Positioning System (GPS) measurements provide a powerful tool for an accurate determination of this origin offset. Two strategies are discussed. The first strategy utilizes the precise relative positions that were predetermined by VLBI to fix the frame orientation and the absolute scaling, while the offset from the geocenter is determined from GPS measurements. Three different cases are presented under this strategy. The reference frame thus adopted will be consistent with the VLBI coordinate system. The second strategy establishes a reference frame by holding only the longitude of one of the tracking sites fixed. The absolute scaling is determined by the adopted gravitational constant (GM) of the Earth; and the latitude is inferred from the time signature of the Earth rotation in the GPS measurements. The coordinate system thus defined will be a geocentric Earth-fixed coordinate system.
NASA Astrophysics Data System (ADS)
Repin, Vladislav A.; Gorbunova, Elena V.; Chertov, Aleksandr N.; Korotaev, Valery V.
2017-06-01
For many applied problems it is necessary to obtain information about the situation in a wide angular field in order to measure various parameters of objects: their spatial coordinates, instantaneous velocities, and so on. In this case, one interesting bionic approach can be used - a mosaic (or discrete, otherwise, facet) angular field. Such electro-optical system constructively imitates the visual apparatus of insects: many photodetectors like ommatidia (elements of the facet eye structure) are located on a non-planar surface. Such devices can be used in photogrammetry and aerial photography systems (if the space is sufficient), in the transport sector as vehicle orientation organs, as systems for monitoring in unmanned aerial vehicles, in endoscopy for obtaining comprehensive information on the state of various cavities, in intelligent robotic systems. In this manuscript discusses the advantages and disadvantages of multi-channeled optoelectronic systems with a mosaic angular field, presents possible options for their use, and discusses some of the design procedures performed when developing a layout of a coordinate measuring device.
Liu, Bailing; Zhang, Fumin; Qu, Xinghua; Shi, Xiaojia
2016-02-18
Coordinate transformation plays an indispensable role in industrial measurements, including photogrammetry, geodesy, laser 3-D measurement and robotics. The widely applied methods of coordinate transformation are generally based on solving the equations of point clouds. Despite the high accuracy, this might result in no solution due to the use of ill conditioned matrices. In this paper, a novel coordinate transformation method is proposed, not based on the equation solution but based on the geometric transformation. We construct characteristic lines to represent the coordinate systems. According to the space geometry relation, the characteristic line scan is made to coincide by a series of rotations and translations. The transformation matrix can be obtained using matrix transformation theory. Experiments are designed to compare the proposed method with other methods. The results show that the proposed method has the same high accuracy, but the operation is more convenient and flexible. A multi-sensor combined measurement system is also presented to improve the position accuracy of a robot with the calibration of the robot kinematic parameters. Experimental verification shows that the position accuracy of robot manipulator is improved by 45.8% with the proposed method and robot calibration.
Liu, Bailing; Zhang, Fumin; Qu, Xinghua; Shi, Xiaojia
2016-01-01
Coordinate transformation plays an indispensable role in industrial measurements, including photogrammetry, geodesy, laser 3-D measurement and robotics. The widely applied methods of coordinate transformation are generally based on solving the equations of point clouds. Despite the high accuracy, this might result in no solution due to the use of ill conditioned matrices. In this paper, a novel coordinate transformation method is proposed, not based on the equation solution but based on the geometric transformation. We construct characteristic lines to represent the coordinate systems. According to the space geometry relation, the characteristic line scan is made to coincide by a series of rotations and translations. The transformation matrix can be obtained using matrix transformation theory. Experiments are designed to compare the proposed method with other methods. The results show that the proposed method has the same high accuracy, but the operation is more convenient and flexible. A multi-sensor combined measurement system is also presented to improve the position accuracy of a robot with the calibration of the robot kinematic parameters. Experimental verification shows that the position accuracy of robot manipulator is improved by 45.8% with the proposed method and robot calibration. PMID:26901203
Improvement of Simulation Method in Validation of Software of the Coordinate Measuring Systems
NASA Astrophysics Data System (ADS)
Nieciąg, Halina
2015-10-01
Software is used in order to accomplish various tasks at each stage of the functioning of modern measuring systems. Before metrological confirmation of measuring equipment, the system has to be validated. This paper discusses the method for conducting validation studies of a fragment of software to calculate the values of measurands. Due to the number and nature of the variables affecting the coordinate measurement results and the complex character and multi-dimensionality of measurands, the study used the Monte Carlo method of numerical simulation. The article presents an attempt of possible improvement of results obtained by classic Monte Carlo tools. The algorithm LHS (Latin Hypercube Sampling) was implemented as alternative to the simple sampling schema of classic algorithm.
Mathematical calibration procedure of a capacitive sensor-based indexed metrology platform
NASA Astrophysics Data System (ADS)
Brau-Avila, A.; Santolaria, J.; Acero, R.; Valenzuela-Galvan, M.; Herrera-Jimenez, V. M.; Aguilar, J. J.
2017-03-01
The demand for faster and more reliable measuring tasks for the control and quality assurance of modern production systems has created new challenges for the field of coordinate metrology. Thus, the search for new solutions in coordinate metrology systems and the need for the development of existing ones still persists. One example of such a system is the portable coordinate measuring machine (PCMM), the use of which in industry has considerably increased in recent years, mostly due to its flexibility for accomplishing in-line measuring tasks as well as its reduced cost and operational advantages compared to traditional coordinate measuring machines. Nevertheless, PCMMs have a significant drawback derived from the techniques applied in the verification and optimization procedures of their kinematic parameters. These techniques are based on the capture of data with the measuring instrument from a calibrated gauge object, fixed successively in various positions so that most of the instrument measuring volume is covered, which results in time-consuming, tedious and expensive verification and optimization procedures. In this work the mathematical calibration procedure of a capacitive sensor-based indexed metrology platform (IMP) is presented. This calibration procedure is based on the readings and geometric features of six capacitive sensors and their targets with nanometer resolution. The final goal of the IMP calibration procedure is to optimize the geometric features of the capacitive sensors and their targets in order to use the optimized data in the verification procedures of PCMMs.
A new type industrial total station based on target automatic collimation
NASA Astrophysics Data System (ADS)
Lao, Dabao; Zhou, Weihu; Ji, Rongyi; Dong, Dengfeng; Xiong, Zhi; Wei, Jiang
2018-01-01
In the case of industrial field measurement, the present measuring instruments work with manual operation and collimation, which give rise to low efficiency for field measurement. In order to solve the problem, a new type industrial total station is presented in this paper. The new instrument can identify and trace cooperative target automatically, in the mean time, coordinate of the target is measured in real time. For realizing the system, key technology including high precision absolutely distance measurement, small high accuracy angle measurement, target automatic collimation with vision, and quick precise controlling should be worked out. After customized system assemblage and adjustment, the new type industrial total station will be established. As the experiments demonstrated, the coordinate accuracy of the instrument is under 15ppm in the distance of 60m, which proved that the measuring system is feasible. The result showed that the total station can satisfy most industrial field measurement requirements.
Assimilation of temperature and salinity profile data in the Norwegian Climate Prediction Model
NASA Astrophysics Data System (ADS)
Wang, Yiguo; Counillon, Francois; Bertino, Laurent; Bethke, Ingo; Keenlyside, Noel
2016-04-01
Assimilating temperature and salinity profile data is promising to constrain the ocean component of Earth system models for the purpose of seasonal-to-dedacal climate predictions. However, assimilating temperature and salinity profiles that are measured in standard depth coordinate (z-coordinate) into isopycnic coordinate ocean models that are discretised by water densities is challenging. Prior studies (Thacker and Esenkov, 2002; Xie and Zhu, 2010) suggested that converting observations to the model coordinate (i.e. innovations in isopycnic coordinate) performs better than interpolating model state to observation coordinate (i.e. innovations in z-coordinate). This problem is revisited here with the Norwegian Climate Prediction Model, which applies the ensemble Kalman filter (EnKF) into the ocean isopycnic model (MICOM) of the Norwegian Earth System Model. We perform Observing System Simulation Experiments (OSSEs) to compare two schemes (the EnKF-z and EnKF-ρ). In OSSEs, the truth is set to the EN4 objective analyses and observations are perturbations of the truth with white noises. Unlike in previous studies, it is found that EnKF-z outperforms EnKF-ρ for different observed vertical resolution, inhomogeneous sampling (e.g. upper 1000 meter observations only), or lack of salinity measurements. That is mostly because the operator converting observations into isopycnic coordinate is strongly non-linear. We also study the horizontal localisation radius at certain arbitrary grid points. Finally, we perform the EnKF-z with the chosen localisation radius in a realistic framework with NorCPM over a 5-year analysis period. The analysis is validated by different independent datasets.
AXAF Coordinate Transformation at XRCF
NASA Technical Reports Server (NTRS)
He, Helen; McDowell, Jonathan; Conroy, Maureen
1997-01-01
Coordinate transformation between focal plane and detector pixel systems must be handled carefully at the X-ray Calibration Facility (XRCF) as it will be during flight. The High Resolution Mirror Assembly (HRMA) X-ray Detection System (HXDS) stage dithers, and the five-axis mount (FAM) attachment points underwent various types of motion during testing. At the XRCF when the FAM moved, the Science Instrument Module (SIM) travel direction was not necessarily aligned with the mirror axis motion, and, in addition, an arbitrary position offset had to be calibrated. Misalignment from the mirror axis was assessed by measuring its displacement from the boresight configuration of the default FAM frame, and the HXDS stage was monitored for motion from the default FAM reference point. Mirror position, prescribed in a mirror modal coordinate system, was measured in HRMA pitch and yaw axes. Prior to corrections for dithering and FAM movement, the coordinate data at XRCF also had to be corrected for possible misalignments of the mirror mount relative to XRCF and the default FAM axes due to the movement of the FAM feet. Those misalignments were processed in terms of yaw-pitch-roll Euler angles in the mirror nodal coordinate, and in the default FAM frame, respectively. An AXAF Science Center (ASC) coordinate library, pixlib, has been built to support these coordinate transformations and was used during x-ray calibration at the George C. Marshall Space Flight Center, Huntsville, AL. The design and implementation of this library will be discussed.
Research on the aircraft level measurement by laser tracker
NASA Astrophysics Data System (ADS)
Ye, Xiaowen; Tang, Wuzhong; Cao, Chun
2014-09-01
The measuring principle of laser tracking system was introduced. The aircraft level measurement was completed by establish the measurement datum mark, select public sites, set up the aircraft coordinate system and transfer stations. Laser tracking measurement technology improved the work efficiency and ensured the installation precision of key components.
NASA Technical Reports Server (NTRS)
McDowell, Mark (Inventor); Glasgow, Thomas K. (Inventor)
1999-01-01
A system and a method for measuring three-dimensional velocities at a plurality of points in a fluid employing at least two cameras positioned approximately perpendicular to one another. The cameras are calibrated to accurately represent image coordinates in world coordinate system. The two-dimensional views of the cameras are recorded for image processing and centroid coordinate determination. Any overlapping particle clusters are decomposed into constituent centroids. The tracer particles are tracked on a two-dimensional basis and then stereo matched to obtain three-dimensional locations of the particles as a function of time so that velocities can be measured therefrom The stereo imaging velocimetry technique of the present invention provides a full-field. quantitative, three-dimensional map of any optically transparent fluid which is seeded with tracer particles.
Minimization of deviations of gear real tooth surfaces determined by coordinate measurements
NASA Technical Reports Server (NTRS)
Litvin, F. L.; Kuan, C.; Wang, J.-C.; Handschuh, R. F.; Masseth, J.; Maruyama, N.
1992-01-01
The deviations of a gear's real tooth surface from the theoretical surface are determined by coordinate measurements at the grid of the surface. A method was developed to transform the deviations from Cartesian coordinates to those along the normal at the measurement locations. Equations are derived that relate the first order deviations with the adjustment to the manufacturing machine-tool settings. The deviations of the entire surface are minimized. The minimization is achieved by application of the least-square method for an overdetermined system of linear equations. The proposed method is illustrated with a numerical example for hypoid gear and pinion.
Close range fault tolerant noncontacting position sensor
Bingham, D.N.; Anderson, A.A.
1996-02-20
A method and system are disclosed for locating the three dimensional coordinates of a moving or stationary object in real time. The three dimensional coordinates of an object in half space or full space are determined based upon the time of arrival or phase of the wave front measured by a plurality of receiver elements and an established vector magnitudes proportional to the measured time of arrival or phase at each receiver element. The coordinates of the object are calculated by solving a matrix equation or a set of closed form algebraic equations. 3 figs.
Imperfection and Thickness Measurement of Panels Using a Coordinate Measurement Machine
NASA Technical Reports Server (NTRS)
Thornburgh, Robert P.
2006-01-01
This paper summarizes the methodology used to measure imperfection and thickness variation for flat and curved panels using a Coordinate Measurement Machine (CMM) and the software program MeasPanel. The objective is to provide a reference document so that someone with a basic understanding of CMM operation can measure a panel with minimal training. Detailed information about both the measurement system setup and computer software is provided. Information is also provided about the format of the raw data, as well as how it is post-processed for use in finite-element analysis.
NASA Technical Reports Server (NTRS)
Jex, H. R.
1971-01-01
System measures intersection of line of sight and eye point of regard /EPR/ for a human operator in visual scanning system. Device measures two head to reference angles with EPR system and adds them with eye to head angles, yielding a dc signal proportional to picture plane coordinates.
NASA Astrophysics Data System (ADS)
Al-Durgham, Kaleel; Lichti, Derek D.; Kuntze, Gregor; Ronsky, Janet
2017-06-01
High-speed biplanar videoradiography, or clinically referred to as dual fluoroscopy (DF), imaging systems are being used increasingly for skeletal kinematics analysis. Typically, a DF system comprises two X-ray sources, two image intensifiers and two high-speed video cameras. The combination of these elements provides time-series image pairs of articulating bones of a joint, which permits the measurement of bony rotation and translation in 3D at high temporal resolution (e.g., 120-250 Hz). Assessment of the accuracy of 3D measurements derived from DF imaging has been the subject of recent research efforts by several groups, however with methodological limitations. This paper presents a novel and simple accuracy assessment procedure based on using precise photogrammetric tools. We address the fundamental photogrammetry principles for the accuracy evaluation of an imaging system. Bundle adjustment with selfcalibration is used for the estimation of the system parameters. The bundle adjustment calibration uses an appropriate sensor model and applies free-network constraints and relative orientation stability constraints for a precise estimation of the system parameters. A photogrammetric intersection of time-series image pairs is used for the 3D reconstruction of a rotating planar object. A point-based registration method is used to combine the 3D coordinates from the intersection and independently surveyed coordinates. The final DF accuracy measure is reported as the distance between 3D coordinates from image intersection and the independently surveyed coordinates. The accuracy assessment procedure is designed to evaluate the accuracy over the full DF image format and a wide range of object rotation. Experiment of reconstruction of a rotating planar object reported an average positional error of 0.44 +/- 0.2 mm in the derived 3D coordinates (minimum 0.05 and maximum 1.2 mm).
Configuration Analysis of the ERS Points in Large-Volume Metrology System
Jin, Zhangjun; Yu, Cijun; Li, Jiangxiong; Ke, Yinglin
2015-01-01
In aircraft assembly, multiple laser trackers are used simultaneously to measure large-scale aircraft components. To combine the independent measurements, the transformation matrices between the laser trackers’ coordinate systems and the assembly coordinate system are calculated, by measuring the enhanced referring system (ERS) points. This article aims to understand the influence of the configuration of the ERS points that affect the transformation matrix errors, and then optimize the deployment of the ERS points to reduce the transformation matrix errors. To optimize the deployment of the ERS points, an explicit model is derived to estimate the transformation matrix errors. The estimation model is verified by the experiment implemented in the factory floor. Based on the proposed model, a group of sensitivity coefficients are derived to evaluate the quality of the configuration of the ERS points, and then several typical configurations of the ERS points are analyzed in detail with the sensitivity coefficients. Finally general guidance is established to instruct the deployment of the ERS points in the aspects of the layout, the volume size and the number of the ERS points, as well as the position and orientation of the assembly coordinate system. PMID:26402685
Particle tracking velocimetry in three-dimensional flows
NASA Astrophysics Data System (ADS)
Maas, H. G.; Gruen, A.; Papantoniou, D.
1993-07-01
Particle Tracking Velocimetry (PTV) is a well-known technique for the determination of velocity vectors within an observation volume. However, for a long time it has rarely been applied because of the intensive effort necessary to measure coordinates of a large number of flow marker particles in many images. With today's imaging hardware in combination with the methods of digital image processing and digital photogrammetry, however, new possibilities have arisen for the design of completely automatic PTV systems. A powerful 3 D PTV has been developed in a cooperation of the Institute of Geodesy and Photogrammetry with the Institute of Hydromechanics and Water Resources Management at the Swiss Federal Institute of Technology. In this paper hardware components for 3 D PTV systems wil be discussed, and a strict mathematical model of photogrammetric 3 D coordinate determination, taking into account the different refractive indices in the optical path, will be presented. The system described is capable of determining coordinate sets of some 1000 particles in a flow field at a time resolution of 25 datasets per second and almost arbitrary sequence length completely automatically after an initialization by an operator. The strict mathematical modelling of the measurement geometry, together with a thorough calibration of the system provide for a coordinate accuracy of typically 0.06 mm in X, Y and 0.18 mm in Z (depth coordinate) in a volume of 200 × 160 × 50 mm3.
NASA Astrophysics Data System (ADS)
Du, Jia-Wei; Wang, Xuan-Yin; Zhu, Shi-Qiang
2017-10-01
Based on the process by which the spatial depth clue is obtained by a single eye, a monocular stereo vision to measure the depth information of spatial objects was proposed in this paper and a humanoid monocular stereo measuring system with two degrees of freedom was demonstrated. The proposed system can effectively obtain the three-dimensional (3-D) structure of spatial objects of different distances without changing the position of the system and has the advantages of being exquisite, smart, and flexible. The bionic optical imaging system we proposed in a previous paper, named ZJU SY-I, was employed and its vision characteristic was just like the resolution decay of the eye's vision from center to periphery. We simplified the eye's rotation in the eye socket and the coordinated rotation of other organs of the body into two rotations in the orthogonal direction and employed a rotating platform with two rotation degrees of freedom to drive ZJU SY-I. The structure of the proposed system was described in detail. The depth of a single feature point on the spatial object was deduced, as well as its spatial coordination. With the focal length adjustment of ZJU SY-I and the rotation control of the rotation platform, the spatial coordinates of all feature points on the spatial object could be obtained and then the 3-D structure of the spatial object could be reconstructed. The 3-D structure measurement experiments of two spatial objects with different distances and sizes were conducted. Some main factors affecting the measurement accuracy of the proposed system were analyzed and discussed.
Study protocol: identifying and delivering point-of-care information to improve care coordination.
Hysong, Sylvia J; Che, Xinxuan; Weaver, Sallie J; Petersen, Laura A
2015-10-19
The need for deliberately coordinated care is noted by many national-level organizations. The Department of Veterans Affairs (VA) recently transitioned primary care clinics nationwide into Patient Aligned Care Teams (PACTs) to provide more accessible, coordinated, comprehensive, and patient-centered care. To better serve this purpose, PACTs must be able to successfully sequence and route interdependent tasks to appropriate team members while also maintaining collective situational awareness (coordination). Although conceptual frameworks of care coordination exist, few explicitly articulate core behavioral markers of coordination or the related information needs of team members attempting to synchronize complex care processes across time for a shared patient population. Given this gap, we partnered with a group of frontline primary care personnel at ambulatory care sites to identify the specific information needs of PACT members that will enable them to coordinate their efforts to provide effective, coordinated care. The study has three objectives: (1) development of measurable, prioritized point-of-care criteria for effective PACT coordination; (2) identifying the specific information needed at the point of care to optimize coordination; and (3) assessing the effect of adopting the aforementioned coordination standards on PACT clinicians' coordination behaviors. The study consists of three phases. In phase 1, we will employ the Productivity Measurement and Enhancement System (ProMES), a structured approach to performance measure creation from industrial/organizational psychology, to develop coordination measures with a design team of 6-10 primary care personnel; in phase 2, we will conduct focus groups with the phase 1 design team to identify point-of-care information needs. Phase 3 is a two-arm field experiment (n PACT = 28/arm); intervention arm PACTs will receive monthly feedback reports using the measures developed in phase 1 and attend brief monthly feedback sessions. Control arm PACTs will receive no intervention. PACTs will be followed prospectively for up to 1 year. This project combines both action research and implementation science methods to address important gaps in the existing care coordination literature using a partnership-based research design. It will provide an evidence-based framework for care coordination by employing a structured methodology for a systematic approach to care coordination in PACT settings and identifying the information needs that produce the most successful coordination of care. ISRCTN15412521.
Technical Note: Robust measurement of the slice-sensitivity profile in breast tomosynthesis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maki, Aili K., E-mail: aili.maki@sri.utoronto.ca
2016-08-15
Purpose: The purpose of this work is to improve the repeatability of the measurement of the slice-sensitivity profile (SSP) in reconstructed breast tomosynthesis volumes. Methods: A grid of aluminum ball-bearings (BBs) within a PMMA phantom was imaged on breast tomosynthesis systems from three different manufacturers. The full-width half-maximum (FWHM) values were measured for the SSPs of the BBs in the reconstructed volumes. The effect of transforming the volumes from a Cartesian coordinate system (CCS) to a cone-beam coordinate system (CBCS) on the variability in the FWHM values was assessed. Results: Transforming the volumes from a CCS to a CBCS beforemore » measuring the SSPs reduced the coefficient of variation (COV) in the measurements of FWHM in repeated measurements by 56% and reduced the dependence of the FWHM values on the location of the BBs within the reconstructed volume by 76%. Conclusions: Measuring the SSP in the volumes in a CBCS improves the robustness of the measurement.« less
Deflection of light to second order: A tool for illustrating principles of general relativity
NASA Astrophysics Data System (ADS)
Bodenner, Jeremiah; Will, Clifford M.
2003-08-01
We calculate the deflection of light by a spherically symmetric body in general relativity, to second order in the quantity GM/dc2, where M is the mass of the body and d is a measure of the distance of closest approach of the ray. Using three different coordinate systems for the Schwarzschild metric we show that the answers for the deflection, while the same at order GM/dc2, differ at order (GM/dc2)2. We demonstrate that all three expressions are really the same by expressing them in terms of measurable, coordinate-independent quantities. These results provide concrete illustrations of the meaning of coordinates and coordinate invariance, which may be useful in teaching general relativity.
Dai, Dongkai; Wang, Xingshu; Zhan, Dejun; Huang, Zongsheng
2014-01-01
A new method for dynamic measurement of deflections of the vertical (DOV) is proposed in this paper. The integration of an inertial navigation system (INS) and global navigation satellite system (GNSS) is constructed to measure the body's attitude with respect to the astronomical coordinates. Simultaneously, the attitude with respect to the geodetic coordinates is initially measured by a star sensor under quasi-static condition and then maintained by the laser gyroscope unit (LGU), which is composed of three gyroscopes in the INS, when the vehicle travels along survey lines. Deflections of the vertical are calculated by using the difference between the attitudes with respect to the geodetic coordinates and astronomical coordinates. Moreover, an algorithm for removing the trend error of the vertical deflections is developed with the aid of Earth Gravitational Model 2008 (EGM2008). In comparison with traditional methods, the new method required less accurate GNSS, because the dynamic acceleration calculation is avoided. The errors of inertial sensors are well resolved in the INS/GNSS integration, which is implemented by a Rauch–Tung–Striebel (RTS) smoother. In addition, a single-axis indexed INS is adopted to improve the observability of the system errors and to restrain the inertial sensor errors. The proposed method is validated by Monte Carlo simulations. The results show that deflections of the vertical can achieve a precision of better than 1″ for a single survey line. The proposed method can be applied to a gravimetry system based on a ground vehicle or ship with a speed lower than 25 m/s. PMID:25192311
Dai, Dongkai; Wang, Xingshu; Zhan, Dejun; Huang, Zongsheng
2014-09-03
A new method for dynamic measurement of deflections of the vertical (DOV) is proposed in this paper. The integration of an inertial navigation system (INS) and global navigation satellite system (GNSS) is constructed to measure the body's attitude with respect to the astronomical coordinates. Simultaneously, the attitude with respect to the geodetic coordinates is initially measured by a star sensor under quasi-static condition and then maintained by the laser gyroscope unit (LGU), which is composed of three gyroscopes in the INS, when the vehicle travels along survey lines. Deflections of the vertical are calculated by using the difference between the attitudes with respect to the geodetic coordinates and astronomical coordinates. Moreover, an algorithm for removing the trend error of the vertical deflections is developed with the aid of Earth Gravitational Model 2008 (EGM2008). In comparison with traditional methods, the new method required less accurate GNSS, because the dynamic acceleration calculation is avoided. The errors of inertial sensors are well resolved in the INS/GNSS integration, which is implemented by a Rauch-Tung-Striebel (RTS) smoother. In addition, a single-axis indexed INS is adopted to improve the observability of the system errors and to restrain the inertial sensor errors. The proposed method is validated by Monte Carlo simulations. The results show that deflections of the vertical can achieve a precision of better than 1″ for a single survey line. The proposed method can be applied to a gravimetry system based on a ground vehicle or ship with a speed lower than 25 m/s.
Qiao, Wei; Venayagamoorthy, Ganesh K; Harley, Ronald G
2008-01-01
Wide-area coordinating control is becoming an important issue and a challenging problem in the power industry. This paper proposes a novel optimal wide-area coordinating neurocontrol (WACNC), based on wide-area measurements, for a power system with power system stabilizers, a large wind farm and multiple flexible ac transmission system (FACTS) devices. An optimal wide-area monitor (OWAM), which is a radial basis function neural network (RBFNN), is designed to identify the input-output dynamics of the nonlinear power system. Its parameters are optimized through particle swarm optimization (PSO). Based on the OWAM, the WACNC is then designed by using the dual heuristic programming (DHP) method and RBFNNs, while considering the effect of signal transmission delays. The WACNC operates at a global level to coordinate the actions of local power system controllers. Each local controller communicates with the WACNC, receives remote control signals from the WACNC to enhance its dynamic performance and therefore helps improve system-wide dynamic and transient performance. The proposed control is verified by simulation studies on a multimachine power system.
Linear CCD attitude measurement system based on the identification of the auxiliary array CCD
NASA Astrophysics Data System (ADS)
Hu, Yinghui; Yuan, Feng; Li, Kai; Wang, Yan
2015-10-01
Object to the high precision flying target attitude measurement issues of a large space and large field of view, comparing existing measurement methods, the idea is proposed of using two array CCD to assist in identifying the three linear CCD with multi-cooperative target attitude measurement system, and to address the existing nonlinear system errors and calibration parameters and more problems with nine linear CCD spectroscopic test system of too complicated constraints among camera position caused by excessive. The mathematical model of binocular vision and three linear CCD test system are established, co-spot composition triangle utilize three red LED position light, three points' coordinates are given in advance by Cooperate Measuring Machine, the red LED in the composition of the three sides of a triangle adds three blue LED light points as an auxiliary, so that array CCD is easier to identify three red LED light points, and linear CCD camera is installed of a red filter to filter out the blue LED light points while reducing stray light. Using array CCD to measure the spot, identifying and calculating the spatial coordinates solutions of red LED light points, while utilizing linear CCD to measure three red LED spot for solving linear CCD test system, which can be drawn from 27 solution. Measured with array CCD coordinates auxiliary linear CCD has achieved spot identification, and has solved the difficult problems of multi-objective linear CCD identification. Unique combination of linear CCD imaging features, linear CCD special cylindrical lens system is developed using telecentric optical design, the energy center of the spot position in the depth range of convergence in the direction is perpendicular to the optical axis of the small changes ensuring highprecision image quality, and the entire test system improves spatial object attitude measurement speed and precision.
Measurement Model Nonlinearity in Estimation of Dynamical Systems
NASA Astrophysics Data System (ADS)
Majji, Manoranjan; Junkins, J. L.; Turner, J. D.
2012-06-01
The role of nonlinearity of the measurement model and its interactions with the uncertainty of measurements and geometry of the problem is studied in this paper. An examination of the transformations of the probability density function in various coordinate systems is presented for several astrodynamics applications. Smooth and analytic nonlinear functions are considered for the studies on the exact transformation of uncertainty. Special emphasis is given to understanding the role of change of variables in the calculus of random variables. The transformation of probability density functions through mappings is shown to provide insight in to understanding the evolution of uncertainty in nonlinear systems. Examples are presented to highlight salient aspects of the discussion. A sequential orbit determination problem is analyzed, where the transformation formula provides useful insights for making the choice of coordinates for estimation of dynamic systems.
NASA Astrophysics Data System (ADS)
Saini, Surender Singh; Sardana, Harish Kumar; Pattnaik, Shyam Sundar
2017-06-01
Conventional image editing software in combination with other techniques are not only difficult to apply to an image but also permits a user to perform some basic functions one at a time. However, image processing algorithms and photogrammetric systems are developed in the recent past for real-time pattern recognition applications. A graphical user interface (GUI) is developed which can perform multiple functions simultaneously for the analysis and estimation of geometric distortion in an image with reference to the corresponding distorted image. The GUI measure, record, and visualize the performance metric of X/Y coordinates of one image over the other. The various keys and icons provided in the utility extracts the coordinates of distortion free reference image and the image with geometric distortion. The error between these two corresponding points gives the measure of distortion and also used to evaluate the correction parameters for image distortion. As the GUI interface minimizes human interference in the process of geometric correction, its execution just requires use of icons and keys provided in the utility; this technique gives swift and accurate results as compared to other conventional methods for the measurement of the X/Y coordinates of an image.
Measurements of Aerodynamic Damping in the MIT Transonic Rotor
NASA Technical Reports Server (NTRS)
Crawley, E. F.
1981-01-01
A method was developed and demonstrated for the direct measurement of aerodynamic forcing and aerodynamic damping of a transonic compressor. The method is based on the inverse solution of the structural dynamic equations of motion of the blade disk system in order to determine the forces acting on the system. The disturbing and damping forces acting on a given blade are determined if the equations of motion are expressed in individual blade coordinates. If the structural dynamic equations are transformed to multiblade coordinates, the damping can be measured for blade disk modes, and related to a reduced frequency and interblade phase angle. In order to measure the aerodynamic damping in this way, the free response to a known excitation is studied.
Development of a coordinate measuring machine (CMM) touch probe using a multi-axis force sensor
NASA Astrophysics Data System (ADS)
Park, Jae-jun; Kwon, Kihwan; Cho, Nahmgyoo
2006-09-01
Traditional touch trigger probes are widely used on most commercial coordinate measuring machines (CMMs). However, the CMMs with these probes have a systematic error due to the shape of the probe tip and elastic deformation of the stylus resulting from contact pressure with the specimen. In this paper, a new touch probe with a three degrees-of-freedom force sensor is proposed. From relationships between an obtained contact force vector and the geometric shape of the probe, it is possible to calculate the coordinates of the exact probe-specimen contact points. An empirical model of the probe is applied to calculate the coordinates of the contact points and the amount of pretravel. With the proposed probing system, the measuring error induced by the indeterminateness of the probe-specimen contact point and the pretravel can be estimated and compensated for successfully.
SU-E-T-570: New Quality Assurance Method Using Motion Tracking for 6D Robotic Couches
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheon, W; Cho, J; Ahn, S
Purpose: To accommodate geometrically accurate patient positioning, a robotic couch that is capable of 6-degrees of freedom has been introduced. However, conventional couch QA methods are not sufficient to enable the necessary accuracy of tests. Therefore, we have developed a camera based motion detection and geometry calibration system for couch QA. Methods: Employing a Visual-Tracking System (VTS, BonitaB10, Vicon, UK) which tracks infrared reflective(IR) markers, camera calibration was conducted using a 5.7 × 5.7 × 5.7 cm{sup 3} cube attached with IR markers at each corner. After positioning a robotic-couch at the origin with the cube on the table top,more » 3D coordinates of the cube’s eight corners were acquired by VTS in the VTS coordinate system. Next, positions in reference coordinates (roomcoordinates) were assigned using the known relation between each point. Finally, camera calibration was completed by finding a transformation matrix between VTS and reference coordinate systems and by applying a pseudo inverse matrix method. After the calibration, the accuracy of linear and rotational motions as well as couch sagging could be measured by analyzing the continuously acquired data of the cube while the couch moves to a designated position. Accuracy of the developed software was verified through comparison with measurement data when using a Laser tracker (FARO, Lake Mary, USA) for a robotic-couch installed for proton therapy. Results: VTS system could track couch motion accurately and measured position in room-coordinates. The VTS measurements and Laser tracker data agreed within 1% of difference for linear and rotational motions. Also because the program analyzes motion in 3-Dimension, it can compute couch sagging. Conclusion: Developed QA system provides submillimeter/ degree accuracy which fulfills the high-end couch QA. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning. (2013M2A2A7043507 and 2012M3A9B6055201)« less
Development features in large-range nanoscale coordinate metrology
NASA Astrophysics Data System (ADS)
Gruhlke, Martin; Recknagel, Christian; Rothe, Hendrik
2008-04-01
The Nanometer-Coordinate-Measuring-Machine (NCMM) has the ability to scan large areas at nanometer resolution for the purpose of quality assurance of nanostructured products. The device combines a conventional atomic force microscope (AFM) with a precise positioning system. By locating the AFM at a fixed point and moving the sample with the positioning system a scan range of 2.5 x 2.5 x 0.5 cm 3 and a repeatability of 0.1 nm is achieved. Since all movements of the positioning system are measured via laser interferometers, the Abbe-principle is kept in every dimension, the use of materials with a low thermal expansion coefficient (like Zerodur and FeNi36) and an overall coordinate system the system provides unique measurement conditions (traceability to the meter definition; repeatable and fast scans of the region of interest). In the past the NCMM was used to make the first large area scan of a microelectronic sample. Our present work focuses on automating critical dimension measurement through the use of a-priori-knowledge of the sample and optical navigation. A-priori-knowledge can be generated by the use of CAD-Data of the sample or scans with white light interferometry. Another present objective is the optimization of the measurement parameters for specific sample topologies using simulation and also empirical methods like the Ziegler-Nichols method. The need of efficient data processing and handling is also part of our current research.
Highly accurate articulated coordinate measuring machine
Bieg, Lothar F.; Jokiel, Jr., Bernhard; Ensz, Mark T.; Watson, Robert D.
2003-12-30
Disclosed is a highly accurate articulated coordinate measuring machine, comprising a revolute joint, comprising a circular encoder wheel, having an axis of rotation; a plurality of marks disposed around at least a portion of the circumference of the encoder wheel; bearing means for supporting the encoder wheel, while permitting free rotation of the encoder wheel about the wheel's axis of rotation; and a sensor, rigidly attached to the bearing means, for detecting the motion of at least some of the marks as the encoder wheel rotates; a probe arm, having a proximal end rigidly attached to the encoder wheel, and having a distal end with a probe tip attached thereto; and coordinate processing means, operatively connected to the sensor, for converting the output of the sensor into a set of cylindrical coordinates representing the position of the probe tip relative to a reference cylindrical coordinate system.
Zhang, Zhi-Feng; Gao, Zhan; Liu, Yuan-Yuan; Jiang, Feng-Chun; Yang, Yan-Li; Ren, Yu-Fen; Yang, Hong-Jun; Yang, Kun; Zhang, Xiao-Dong
2012-01-01
Train wheel sets must be periodically inspected for possible or actual premature failures and it is very significant to record the wear history for the full life of utilization of wheel sets. This means that an online measuring system could be of great benefit to overall process control. An online non-contact method for measuring a wheel set's geometric parameters based on the opto-electronic measuring technique is presented in this paper. A charge coupled device (CCD) camera with a selected optical lens and a frame grabber was used to capture the image of the light profile of the wheel set illuminated by a linear laser. The analogue signals of the image were transformed into corresponding digital grey level values. The 'mapping function method' is used to transform an image pixel coordinate to a space coordinate. The images of wheel sets were captured when the train passed through the measuring system. The rim inside thickness and flange thickness were measured and analyzed. The spatial resolution of the whole image capturing system is about 0.33 mm. Theoretic and experimental results show that the online measurement system based on computer vision can meet wheel set measurement requirements.
Identification of Communication and Coordination Issues in the US Air Traffic Control System
NASA Technical Reports Server (NTRS)
Davison, Hayley J.; Hansman, R. John
2001-01-01
Today's air traffic control system is approaching the point of saturation, as evidenced by increasing delays across the National Airspace System (NAS). There exists an opportunity to enhance NAS efficiency and reduce delays by improving strategic communication throughout the ATC system. Although several measures have been taken to improve communication (e.g., Collaborative Decision Making tools), communication issues between ATC facilities remain. It is hypothesized that by identifying the key issues plaguing inter-facility strategic communication, steps can be taken to enhance these communications, and therefore ATC system efficiency. In this report, a series of site visits were performed at Boston and New York ATC facilities as well as at the Air Traffic Control System Command Center. The results from these site visits were used to determine the current communication and coordination structure of Traffic Management Coordinators, who hold a pivotal role in inter-facility communications. Several themes emerged from the study, including: ambiguity of organizational structure in the current ATC system, awkward coordination between ATC facilities, information flow issues, organizational culture issues, and negotiation behaviors used to cope with organizational culture issues.
Analysis of a new phase and height algorithm in phase measurement profilometry
NASA Astrophysics Data System (ADS)
Bian, Xintian; Zuo, Fen; Cheng, Ju
2018-04-01
Traditional phase measurement profilometry adopts divergent illumination to obtain the height distribution of a measured object accurately. However, the mapping relation between reference plane coordinates and phase distribution must be calculated before measurement. Data are then stored in a computer in the form of a data sheet for standby applications. This study improved the distribution of projected fringes and deducted the phase-height mapping algorithm when the two pupils of the projection and imaging systems are of unequal heights and when the projection and imaging axes are on different planes. With the algorithm, calculating the mapping relation between reference plane coordinates and phase distribution prior to measurement is unnecessary. Thus, the measurement process is simplified, and the construction of an experimental system is made easy. Computer simulation and experimental results confirm the effectiveness of the method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shchory, Tal; Schifter, Dan; Lichtman, Rinat
Purpose: In radiation therapy there is a need to accurately know the location of the target in real time. A novel radioactive tracking technology has been developed to answer this need. The technology consists of a radioactive implanted fiducial marker designed to minimize migration and a linac mounted tracking device. This study measured the static and dynamic accuracy of the new tracking technology in a clinical radiation therapy environment. Methods and Materials: The tracking device was installed on the linac gantry. The radioactive marker was located in a tissue equivalent phantom. Marker location was measured simultaneously by the radioactive trackingmore » system and by a Microscribe G2 coordinate measuring machine (certified spatial accuracy of 0.38 mm). Localization consistency throughout a volume and absolute accuracy in the Fixed coordinate system were measured at multiple gantry angles over volumes of at least 10 cm in diameter centered at isocenter. Dynamic accuracy was measured with the marker located inside a breathing phantom. Results: The mean consistency for the static source was 0.58 mm throughout the tested region at all measured gantry angles. The mean absolute position error in the Fixed coordinate system for all gantry angles was 0.97 mm. The mean real-time tracking error for the dynamic source within the breathing phantom was less than 1 mm. Conclusions: This novel radioactive tracking technology has the potential to be useful in accurate target localization and real-time monitoring for radiation therapy.« less
Shchory, Tal; Schifter, Dan; Lichtman, Rinat; Neustadter, David; Corn, Benjamin W
2010-11-15
In radiation therapy there is a need to accurately know the location of the target in real time. A novel radioactive tracking technology has been developed to answer this need. The technology consists of a radioactive implanted fiducial marker designed to minimize migration and a linac mounted tracking device. This study measured the static and dynamic accuracy of the new tracking technology in a clinical radiation therapy environment. The tracking device was installed on the linac gantry. The radioactive marker was located in a tissue equivalent phantom. Marker location was measured simultaneously by the radioactive tracking system and by a Microscribe G2 coordinate measuring machine (certified spatial accuracy of 0.38 mm). Localization consistency throughout a volume and absolute accuracy in the Fixed coordinate system were measured at multiple gantry angles over volumes of at least 10 cm in diameter centered at isocenter. Dynamic accuracy was measured with the marker located inside a breathing phantom. The mean consistency for the static source was 0.58 mm throughout the tested region at all measured gantry angles. The mean absolute position error in the Fixed coordinate system for all gantry angles was 0.97 mm. The mean real-time tracking error for the dynamic source within the breathing phantom was less than 1 mm. This novel radioactive tracking technology has the potential to be useful in accurate target localization and real-time monitoring for radiation therapy. Copyright © 2010 Elsevier Inc. All rights reserved.
Measuring public health practice and outcomes in chronic disease: a call for coordination.
Porterfield, Deborah S; Rogers, Todd; Glasgow, LaShawn M; Beitsch, Leslie M
2015-04-01
A strategic opportunity exists to coordinate public health systems and services researchers' efforts to develop local health department service delivery measures and the efforts of divisions within the Centers for Disease Control and Prevention's National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP) to establish outcome indicators for public health practice in chronic disease. Several sets of outcome indicators developed by divisions within NCCDPHP and intended for use by state programs can be tailored to assess outcomes of interventions within smaller geographic areas or intervention settings. Coordination of measurement efforts could potentially allow information to flow from the local to the state to the federal level, enhancing program planning, accountability, and even subsequent funding for public health practice.
An in-situ measuring method for planar straightness error
NASA Astrophysics Data System (ADS)
Chen, Xi; Fu, Luhua; Yang, Tongyu; Sun, Changku; Wang, Zhong; Zhao, Yan; Liu, Changjie
2018-01-01
According to some current problems in the course of measuring the plane shape error of workpiece, an in-situ measuring method based on laser triangulation is presented in this paper. The method avoids the inefficiency of traditional methods like knife straightedge as well as the time and cost requirements of coordinate measuring machine(CMM). A laser-based measuring head is designed and installed on the spindle of a numerical control(NC) machine. The measuring head moves in the path planning to measure measuring points. The spatial coordinates of the measuring points are obtained by the combination of the laser triangulation displacement sensor and the coordinate system of the NC machine, which could make the indicators of measurement come true. The method to evaluate planar straightness error adopts particle swarm optimization(PSO). To verify the feasibility and accuracy of the measuring method, simulation experiments were implemented with a CMM. Comparing the measurement results of measuring head with the corresponding measured values obtained by composite measuring machine, it is verified that the method can realize high-precise and automatic measurement of the planar straightness error of the workpiece.
Diffeomorphometry and geodesic positioning systems for human anatomy.
Miller, Michael I; Younes, Laurent; Trouvé, Alain
2014-03-01
The Computational Anatomy project has largely been a study of large deformations within a Riemannian framework as an efficient point of view for generating metrics between anatomical configurations. This approach turns D'Arcy Thompson's comparative morphology of human biological shape and form into a metrizable space. Since the metric is constructed based on the geodesic length of the flows of diffeomorphisms connecting the forms, we call it diffeomorphometry . Just as importantly, since the flows describe algebraic group action on anatomical submanifolds and associated functional measurements, they become the basis for positioning information, which we term geodesic positioning . As well the geodesic connections provide Riemannian coordinates for locating forms in the anatomical orbit, which we call geodesic coordinates . These three components taken together - the metric, geodesic positioning of information, and geodesic coordinates - we term the geodesic positioning system . We illustrate via several examples in human and biological coordinate systems and machine learning of the statistical representation of shape and form.
Optical Testing Using Portable Laser Coordinate Measuring Instruments
NASA Technical Reports Server (NTRS)
Khreishi, Manal; Ohl, Raymond G.; Mclean, Kyle F.; Hadjimichael, Theodore J.; Hayden, Joseph E.
2017-01-01
High precision, portable coordinate measuring instruments (CMI) such as laser radars (LR) and laser trackers (LT) have been used for optical system alignment and integration. The LR's ability to perform a non-contact scan of surfaces was previously utilized to characterize large spherical and aspheric mirrors. In this paper, we explore the use of a CMI as an accurate, fast, robust, and non-contact tool for prescription characterization of powered optical surfaces. Using Nikon's MV-224/350 LR and Leica's Absolute Tracker AT401/402 instruments, proof of concept measurements were performed to characterize a variety of optical components by measuring the actual and apparent, or equivalently the "direct and through" (D&T), coordinates of calibrated metrology targets. Custom macros in metrology software and other data reduction code were developed to compute surface-ray intercepts and surface slopes from the D&T shots. The calculated data is fit to an aspheric surface formula to obtain the optimum prescription. The results were compared to the nominal parameters and were crosschecked using LR scans or other approaches. We discuss potential applications across the fields of optical component fabrication and system alignment and testing.
Optical Testing Using Portable Laser Coordinate Measuring Instruments
NASA Technical Reports Server (NTRS)
Khreishi, M.; Ohl, R.; Mclean, K.; Hadjimichael, T.; Hayden, J.
2017-01-01
High precision, portable coordinate measuring instruments (CMI) such as laser radars (LR) and laser trackers (LT) have been used for optical system alignment and integration. The LRs ability to perform a non-contact scan of surfaces was previously utilized to characterize large spherical and aspheric mirrors. In this paper, we explore the use of a CMI as an accurate, fast, robust, and non-contact tool for prescription characterization of powered optical surfaces. Using Nikons MV-224350 LR and Leicas Absolute Tracker AT401402 instruments, proof of concept measurements were performed to characterize a variety of optical components by measuring the actual and apparent, or equivalently the direct and through (DT), coordinates of calibrated metrology targets. Custom macros in metrology software and other data reduction code were developed to compute surface-ray intercepts and surface slopes from the DT shots. The calculated data is fit to an aspheric surface formula to obtain the optimum prescription. The results were compared to the nominal parameters and were crosschecked using LR scans or other approaches. We discuss potential applications across the fields of optical component fabrication and system alignment and testing.
NASA Astrophysics Data System (ADS)
Ozer, Ekin; Feng, Maria Q.
2017-04-01
Mobile, heterogeneous, and smart sensor networks produce pervasive structural health monitoring (SHM) information. With various embedded sensors, smartphones have emerged to innovate SHM by empowering citizens to serve as sensors. By default, smartphones meet the fundamental smart sensor criteria, thanks to the built-in processor, memory, wireless communication units and mobile operating system. SHM using smartphones, however, faces technical challenges due to citizen-induced uncertainties, undesired sensor-structure integration, and lack of control over the sensing platform. Previously, the authors presented successful applications of smartphone accelerometers for structural vibration measurement and proposed a monitoring framework under citizen-induced spatiotemporal uncertainties. This study aims at extending the capabilities of smartphone-based SHM with a special focus on the lack of control over the sensor (i.e., the phone) positioning by citizens resulting in unknown sensor orientations. Using smartphone gyroscope, accelerometer, and magnetometer; instantaneous sensor orientation can be obtained with respect to gravitational and magnetic north directions. Using these sensor data, mobile operating system frameworks return processed features such as attitude and heading that can be used to correct misaligned sensor signals. For this purpose, a coordinate transformation procedure is proposed and illustrated on a two-story laboratory structural model and real-scale bridges with various sensor positioning examples. The proposed method corrects the sensor signals by tracking their orientations and improves measurement accuracy. Moreover, knowing structure’s coordinate system a priori, even the data from arbitrarily positioned sensors can automatically be transformed to the structural coordinates. In addition, this paper also touches some secondary mobile and heterogeneous data issues including imperfect sampling and geolocation services. The coordinate system transformation methods proposed in this study can be implemented in other non-smartphone-based SHM systems as long as similar instrumentation is available.
Castellini, Paolo; Di Giuseppe, Andrea
2008-06-01
This paper describes the development of a system for measuring surface coordinates (commonly known as "shape measurements") which is able to give the temporal evolution of the position of the tire sidewall in transient conditions (such as during braking, when there are potholes or when the road surface is uneven) which may or may not be reproducible. The system is based on the well-known technique of projecting and observing structured light using a digital camera with an optical axis which is slanted with respect to the axis of the projector. The transient nature of the phenomenon has led to the development of specific innovative solutions as regards image processing algorithms. This paper briefly describes the components which make up the measuring system and presents the results of the measurements carried out on the drum bench. It then analyses the performance of the measuring system and the sources of uncertainty which led to the development of the system for a specific dynamic application: impact with an obstacle (cleat test). The measuring system guaranteed a measurement uncertainty of 0.28 mm along the Z axis (the axial direction of the tire) with a measurement range of 250(X) x 80(Y) x 25(Z) mm(3), with the tire rolling at a speed of up to 30 km/h.
Applications of Differential Operators in Geodetic Coordinates
NASA Astrophysics Data System (ADS)
Hallam, K. A. T.; Oliveira, V. C., Jr.
2016-12-01
The definition of coordinate systems and frames is an essential step to even start a problem in physical geodesy and geophysics. The commonly used coordinate systems when dealing with problems on (or close to) the surface of the Earth are the geocentric Cartesian coordinates, geocentric spherical coordinates and geodetic coordinates. Transformations between Cartesian and spherical coordinates are widely known and used for several problems. More complex, but not less important, are the transformations between Cartesian and geodetic coordinates. Although most of them utilize an ellipsoidal frame in which the three coordinates are geodetic longitude (λ), geodetic latitude (φ) and the scale factor (u), the latter being a combination of X and Y, not the geometric height (h), the data sets measured on (or close to) the surface of the Earth are given in geodetic coordinates which are usually transformed into Cartesian or spherical coordinates for mathematical developments. It would be useful, however, to preclude coordinate transformations for the subsequent operations. Thus, we derived expressions for the gradient and Laplacian operators in geodetic coordinates in order to make further use on mathematical developments. Results obtained analitically and from numerical simulations validate our expressions. We applied our operators to derive the gravitational field produced by a point mass and used it for representing the regional gravity field in geodetic coordinates. The results obtained with the numerical simulations show that our approach is potentially useful in solving a wide range of problems in physical geodesy and geophysics.
Tutorial: Crystal orientations and EBSD — Or which way is up?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Britton, T.B., E-mail: b.britton@imperial.ac.uk; Jiang, J.; Guo, Y.
2016-07-15
Electron backscatter diffraction (EBSD) is an automated technique that can measure the orientation of crystals in a sample very rapidly. There are many sophisticated software packages that present measured data. Unfortunately, due to crystal symmetry and differences in the set-up of microscope and EBSD software, there may be accuracy issues when linking the crystal orientation to a particular microstructural feature. In this paper we outline a series of conventions used to describe crystal orientations and coordinate systems. These conventions have been used to successfully demonstrate that a consistent frame of reference is used in the sample, unit cell, pole figuremore » and diffraction pattern frames of reference. We establish a coordinate system rooted in measurement of the diffraction pattern and subsequently link this to all other coordinate systems. A fundamental outcome of this analysis is to note that the beamshift coordinate system needs to be precisely defined for consistent 3D microstructure analysis. This is supported through a series of case studies examining particular features of the microscope settings and/or unambiguous crystallographic features. These case studies can be generated easily in most laboratories and represent an opportunity to demonstrate confidence in use of recorded orientation data. Finally, we include a simple software tool, written in both MATLAB® and Python, which the reader can use to compare consistency with their own microscope set-up and which may act as a springboard for further offline analysis. - Highlights: • Presentation of conventions used to describe crystal orientations • Three case studies that outline how conventions are consistent • Demonstrates a pathway for calibration and validation of EBSD based orientation measurements • EBSD computer code supplied for validation by the reader.« less
Modification of LAMPF's magnet-mapping code for offsets of center coordinates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurd, J.W.; Gomulka, S.; Merrill, F.
1991-01-01
One of the magnet measurements performed at LAMPF is the determination of the cylindrical harmonics of a quadrupole magnet using a rotating coil. The data are analyzed with the code HARMAL to derive the amplitudes of the harmonics. Initially, the origin of the polar coordinate system is the axis of the rotating coil. A new coordinate system is found by a simple translation of the old system such that the dipole moment in the new system is zero. The origin of this translated system is referred to as the magnetic center. Given this translation, the code calculates the coefficients ofmore » the cylindrical harmonics in the new system. The code has been modified to use an analytical calculation to determine these new coefficients. The method of calculation is described and some implications of this formulation are presented. 8 refs., 2 figs.« less
Wu, Jun; Yu, Zhijing; Zhuge, Jingchang
2016-04-01
A rotating laser positioning system (RLPS) is an efficient measurement method for large-scale metrology. Due to multiple transmitter stations, which consist of a measurement network, the position relationship of these stations must be first calibrated. However, with such auxiliary devices such as a laser tracker, scale bar, and complex calibration process, the traditional calibration methods greatly reduce the measurement efficiency. This paper proposes a self-calibration method for RLPS, which can automatically obtain the position relationship. The method is implemented through interscanning technology by using a calibration bar mounted on the transmitter station. Each bar is composed of three RLPS receivers and one ultrasonic sensor whose coordinates are known in advance. The calibration algorithm is mainly based on multiplane and distance constraints and is introduced in detail through a two-station mathematical model. The repeated experiments demonstrate that the coordinate measurement uncertainty of spatial points by using this method is about 0.1 mm, and the accuracy experiments show that the average coordinate measurement deviation is about 0.3 mm compared with a laser tracker. The accuracy can meet the requirements of most applications, while the calibration efficiency is significantly improved.
NASA Astrophysics Data System (ADS)
Reed, Judd E.; Rumberger, John A.; Buithieu, Jean; Behrenbeck, Thomas; Breen, Jerome F.; Sheedy, Patrick F., II
1995-05-01
Following myocardial infarction, the size of the infarcted region and the systolic functioning of the noninfarcted region are commonly assessed by various cross- sectional imaging techniques. A series of images representing successive phases of the cardiac cycle can be acquired by several imaging modalities including electron beam computed tomography, magnetic resonance imaging, and echocardiography. For the assessment of patterns of ventricular contraction, images are commonly acquired of ventricular cross-sections normal to the 'long' axis of the heart and parallel to the mitral valve plane. The endocardial and epicardial surfaces of the myocardium are identified. Then the ventricle is divided into sectors and the volumes of blood and myocardium within each sector at multiple phases of the cardiac cycle are measured. Regional function parameters are derived from these measurements. This generally mandates the use of a polar or cylindrical coordinate system. Various algorithms have been used to select the origin of this coordinate system. These include the centroid of the endocardial surface, the epicardial surface, or of a polygon whose vertices lie midway between the epicardial and endocardial surfaces of the myocardium (centerline method). Another algorithm has been developed in our laboratory. This uses the centroid (or center of mass) of the myocardium exclusive of the ventricular cavity. Each of these choices for origin of coordinate system can be derived from the end- diastolic image or from the end-systolic image. Alternately, new coordinate systems can be selected for each phase of the cardiac cycle. These are referred to as 'floating' coordinate systems. A series of computer models have been developed in our laboratory to study the effects of each of these choices on the regional function parameters of normal ventricles and how these choices effect the quantification of regional abnormalities after myocardial infarction. The most sophisticated of these is an interactive program with a graphical user interface which facilitates the simulation of a wide variety of dynamic ventricular cross sections. Analysis of these simulations has led to a better understanding of how polar coordinate system placement influences the results of quantitative regional ventricular function assessment. It has also created new insight into how the appropriateness of the placement of such a polar coordinate systems can be objectively assessed. The validity of the conclusions drawn from the analysis of simulated ventricular shapes was validated through the analysis of outlines extracted from cine electron beam computed tomographic images. This was done using another interactive software tool developed specifically for this purpose. With this tool, the effects on regional function parameters of various choices for origin placement can be directly observed. This has proven to reinforce the conclusions drawn from the simulations and has led to the modification of the procedures used in our laboratory. Conclusions: The so-called floating coordinate systems are superior to fixed ones for quantification of regional left ventricular contraction in almost every respect. The use of regional ejection fractions with a coordinate system origin located at the centroid of the endocardial surface can lead to 180 degree errors in identifying the location of a myocardial infarction. This problem is less pronounced with midline and epicardium- based centroids and does not occur when the centroid of the myocardium is used. The quantified migration of myocardial mass across sector boundaries is a useful indicator of an inappropriate choice of coordinate system origin. When the centroid of the myocardium falls well within the ventricular cavity, as it usually does, it is a better location for the origin for regional analysis than any of the other centroids analyzed.
Yang, Zhongming; Wang, Kailiang; Cheng, Jinlong; Gao, Zhishan; Yuan, Qun
2016-06-10
We have proposed a virtual quadratic Newton rings phase-shifting moiré-fringes measurement method in a nonnull interferometer to measure the large radius of curvature for a spherical surface. In a quadratic polar coordinate system, linear carrier testing Newton rings interferogram and virtual Newton rings interferogram form the moiré fringes. It is possible to retrieve the wavefront difference data between the testing and standard spherical surface from the moiré fringes after low-pass filtering. Based on the wavefront difference data, we deduced a precise formula to calculate the radius of curvature in the quadratic polar coordinate system. We calculated the retrace error in the nonnull interferometer using the multi-configuration model of the nonnull interferometric system in ZEMAX. Our experimental results indicate that the measurement accuracy is better than 0.18% for a spherical mirror with a radius of curvature of 41,400 mm.
Photogrammetry for rapid prototyping: development of noncontact 3D reconstruction technologies
NASA Astrophysics Data System (ADS)
Knyaz, Vladimir A.
2002-04-01
An important stage of rapid prototyping technology is generating computer 3D model of an object to be reproduced. Wide variety of techniques for 3D model generation exists beginning with manual 3D models generation and finishing with full-automated reverse engineering system. The progress in CCD sensors and computers provides the background for integration of photogrammetry as an accurate 3D data source with CAD/CAM. The paper presents the results of developing photogrammetric methods for non-contact spatial coordinates measurements and generation of computer 3D model of real objects. The technology is based on object convergent images processing for calculating its 3D coordinates and surface reconstruction. The hardware used for spatial coordinates measurements is based on PC as central processing unit and video camera as image acquisition device. The original software for Windows 9X realizes the complete technology of 3D reconstruction for rapid input of geometry data in CAD/CAM systems. Technical characteristics of developed systems are given along with the results of applying for various tasks of 3D reconstruction. The paper describes the techniques used for non-contact measurements and the methods providing metric characteristics of reconstructed 3D model. Also the results of system application for 3D reconstruction of complex industrial objects are presented.
NASA Astrophysics Data System (ADS)
Kaburaki, Kaori; Mozumi, Michiya; Hasegawa, Hideyuki
2018-07-01
Methods for the estimation of two-dimensional (2D) velocity and displacement of physiological tissues are necessary for quantitative diagnosis. In echocardiography with a phased array probe, the accuracy in the estimation of the lateral motion is lower than that of the axial motion. To improve the accuracy in the estimation of the lateral motion, in the present study, the coordinate system for ultrasonic beamforming was changed from the conventional polar coordinate to the Cartesian coordinate. In a basic experiment, the motion velocity of a phantom, which was moved at a constant speed, was estimated by the conventional and proposed methods. The proposed method reduced the bias error and standard deviation in the estimated motion velocities. In an in vivo measurement, intracardiac blood flow was analyzed by the proposed method.
Barycentric parameterizations for isotropic BRDFs.
Stark, Michael M; Arvo, James; Smits, Brian
2005-01-01
A bidirectional reflectance distribution function (BRDF) is often expressed as a function of four real variables: two spherical coordinates in each of the the "incoming" and "outgoing" directions. However, many BRDFs reduce to functions of fewer variables. For example, isotropic reflection can be represented by a function of three variables. Some BRDF models can be reduced further. In this paper, we introduce new sets of coordinates which we use to reduce the dimensionality of several well-known analytic BRDFs as well as empirically measured BRDF data. The proposed coordinate systems are barycentric with respect to a triangular support with a direct physical interpretation. One coordinate set is based on the BRDF model proposed by Lafortune. Another set, based on a model of Ward, is associated with the "halfway" vector common in analytical BRDF formulas. Through these coordinate sets we establish lower bounds on the approximation error inherent in the models on which they are based. We present a third set of coordinates, not based on any analytical model, that performs well in approximating measured data. Finally, our proposed variables suggest novel ways of constructing and visualizing BRDFs.
Coordinated XTE/EUVE Observations of Algol
NASA Technical Reports Server (NTRS)
Stern, Robert A.
1997-01-01
EUVE, ASCA, and XTE observed the eclipsing binary Algol (Beta Per) from 1-7 Feb. 96. The coordinated observation covered approximately 2 binary orbits of the system, with a net exposure of approximately 160 ksec for EUVE, 40 ksec for ASCA (in 4 pointing), and 90 ksec for XTE (in 45 pointings). We discuss results of modeling the combined EUVE, ASCA, and XTE data using continuous differential emission measure distributions, and provide constraints on the Fe abundance in the Algol system.
Phase diagram of the Pr-Mn-O system in composition-temperature-oxygen pressure coordinates
NASA Astrophysics Data System (ADS)
Vedmid', L. B.; Yankin, A. M.; Fedorova, O. M.; Kozin, V. M.
2016-05-01
The phase relations in the Pr-Mn-O system were studied by the static method at lowered oxygen pressure in combination with thermal analysis and high-temperature X-ray diffraction. The equilibrium oxygen pressure in dissociation of PrMn2O5 and PrMnO3 was measured, and the thermodynamic characteristics of formation of these compounds from elements were calculated. The P- T- x phase diagram of the Pr-Mn-O system was constructed in the "composition-oxygen pressure-temperature" coordinates.
Du, Hui; Chen, Xiaobo; Xi, Juntong; Yu, Chengyi; Zhao, Bao
2017-12-12
Large-scale surfaces are prevalent in advanced manufacturing industries, and 3D profilometry of these surfaces plays a pivotal role for quality control. This paper proposes a novel and flexible large-scale 3D scanning system assembled by combining a robot, a binocular structured light scanner and a laser tracker. The measurement principle and system construction of the integrated system are introduced. A mathematical model is established for the global data fusion. Subsequently, a robust method is introduced for the establishment of the end coordinate system. As for hand-eye calibration, the calibration ball is observed by the scanner and the laser tracker simultaneously. With this data, the hand-eye relationship is solved, and then an algorithm is built to get the transformation matrix between the end coordinate system and the world coordinate system. A validation experiment is designed to verify the proposed algorithms. Firstly, a hand-eye calibration experiment is implemented and the computation of the transformation matrix is done. Then a car body rear is measured 22 times in order to verify the global data fusion algorithm. The 3D shape of the rear is reconstructed successfully. To evaluate the precision of the proposed method, a metric tool is built and the results are presented.
A new position measurement system using a motion-capture camera for wind tunnel tests.
Park, Hyo Seon; Kim, Ji Young; Kim, Jin Gi; Choi, Se Woon; Kim, Yousok
2013-09-13
Considering the characteristics of wind tunnel tests, a position measurement system that can minimize the effects on the flow of simulated wind must be established. In this study, a motion-capture camera was used to measure the displacement responses of structures in a wind tunnel test, and the applicability of the system was tested. A motion-capture system (MCS) could output 3D coordinates using two-dimensional image coordinates obtained from the camera. Furthermore, this remote sensing system had some flexibility regarding lab installation because of its ability to measure at relatively long distances from the target structures. In this study, we performed wind tunnel tests on a pylon specimen and compared the measured responses of the MCS with the displacements measured with a laser displacement sensor (LDS). The results of the comparison revealed that the time-history displacement measurements from the MCS slightly exceeded those of the LDS. In addition, we confirmed the measuring reliability of the MCS by identifying the dynamic properties (natural frequency, damping ratio, and mode shape) of the test specimen using system identification methods (frequency domain decomposition, FDD). By comparing the mode shape obtained using the aforementioned methods with that obtained using the LDS, we also confirmed that the MCS could construct a more accurate mode shape (bending-deflection mode shape) with the 3D measurements.
A New Position Measurement System Using a Motion-Capture Camera for Wind Tunnel Tests
Park, Hyo Seon; Kim, Ji Young; Kim, Jin Gi; Choi, Se Woon; Kim, Yousok
2013-01-01
Considering the characteristics of wind tunnel tests, a position measurement system that can minimize the effects on the flow of simulated wind must be established. In this study, a motion-capture camera was used to measure the displacement responses of structures in a wind tunnel test, and the applicability of the system was tested. A motion-capture system (MCS) could output 3D coordinates using two-dimensional image coordinates obtained from the camera. Furthermore, this remote sensing system had some flexibility regarding lab installation because of its ability to measure at relatively long distances from the target structures. In this study, we performed wind tunnel tests on a pylon specimen and compared the measured responses of the MCS with the displacements measured with a laser displacement sensor (LDS). The results of the comparison revealed that the time-history displacement measurements from the MCS slightly exceeded those of the LDS. In addition, we confirmed the measuring reliability of the MCS by identifying the dynamic properties (natural frequency, damping ratio, and mode shape) of the test specimen using system identification methods (frequency domain decomposition, FDD). By comparing the mode shape obtained using the aforementioned methods with that obtained using the LDS, we also confirmed that the MCS could construct a more accurate mode shape (bending-deflection mode shape) with the 3D measurements. PMID:24064600
Articulated Arm Coordinate Measuring Machine Calibration by Laser Tracker Multilateration
Majarena, Ana C.; Brau, Agustín; Velázquez, Jesús
2014-01-01
A new procedure for the calibration of an articulated arm coordinate measuring machine (AACMM) is presented in this paper. First, a self-calibration algorithm of four laser trackers (LTs) is developed. The spatial localization of a retroreflector target, placed in different positions within the workspace, is determined by means of a geometric multilateration system constructed from the four LTs. Next, a nonlinear optimization algorithm for the identification procedure of the AACMM is explained. An objective function based on Euclidean distances and standard deviations is developed. This function is obtained from the captured nominal data (given by the LTs used as a gauge instrument) and the data obtained by the AACMM and compares the measured and calculated coordinates of the target to obtain the identified model parameters that minimize this difference. Finally, results show that the procedure presented, using the measurements of the LTs as a gauge instrument, is very effective by improving the AACMM precision. PMID:24688418
A coordination theory for intelligent machines
NASA Technical Reports Server (NTRS)
Wang, Fei-Yue; Saridis, George N.
1990-01-01
A formal model for the coordination level of intelligent machines is established. The framework of the coordination level investigated consists of one dispatcher and a number of coordinators. The model called coordination structure has been used to describe analytically the information structure and information flow for the coordination activities in the coordination level. Specifically, the coordination structure offers a formalism to (1) describe the task translation of the dispatcher and coordinators; (2) represent the individual process within the dispatcher and coordinators; (3) specify the cooperation and connection among the dispatcher and coordinators; (4) perform the process analysis and evaluation; and (5) provide a control and communication mechanism for the real-time monitor or simulation of the coordination process. A simple procedure for the task scheduling in the coordination structure is presented. The task translation is achieved by a stochastic learning algorithm. The learning process is measured with entropy and its convergence is guaranteed. Finally, a case study of the coordination structure with three coordinators and one dispatcher for a simple intelligent manipulator system illustrates the proposed model and the simulation of the task processes performed on the model verifies the soundness of the theory.
Romero, Veronica; Amaral, Joseph; Fitzpatrick, Paula; Schmidt, R C; Duncan, Amie W; Richardson, Michael J
2017-04-01
Functionally stable and robust interpersonal motor coordination has been found to play an integral role in the effectiveness of social interactions. However, the motion-tracking equipment required to record and objectively measure the dynamic limb and body movements during social interaction has been very costly, cumbersome, and impractical within a non-clinical or non-laboratory setting. Here we examined whether three low-cost motion-tracking options (Microsoft Kinect skeletal tracking of either one limb or whole body and a video-based pixel change method) can be employed to investigate social motor coordination. Of particular interest was the degree to which these low-cost methods of motion tracking could be used to capture and index the coordination dynamics that occurred between a child and an experimenter for three simple social motor coordination tasks in comparison to a more expensive, laboratory-grade motion-tracking system (i.e., a Polhemus Latus system). Overall, the results demonstrated that these low-cost systems cannot substitute the Polhemus system in some tasks. However, the lower-cost Microsoft Kinect skeletal tracking and video pixel change methods were successfully able to index differences in social motor coordination in tasks that involved larger-scale, naturalistic whole body movements, which can be cumbersome and expensive to record with a Polhemus. However, we found the Kinect to be particularly vulnerable to occlusion and the pixel change method to movements that cross the video frame midline. Therefore, particular care needs to be taken in choosing the motion-tracking system that is best suited for the particular research.
ERIC Educational Resources Information Center
Shannon, Lisa M.; Walker, Robert; Blevins, Michele
2009-01-01
This paper presents information on re-developing an outcome evaluation for a state-funded program providing service coordination utilizing wraparound to youth with severe emotional disturbance (SED) and their families. Originally funded by the Robert Wood Johnson Foundation, the Kentucky IMPACT program has existed statewide since 1990. Changing…
Measuring levee elevation heights in North Louisiana.
DOT National Transportation Integrated Search
2010-01-01
The primary goals of this research are to measure the elevation and centerline coordinates of the top of federal and local levees and also to ensure that the resulting global positioning system (GPS) measurement data is within a precision interval of...
Aller, Marta-Beatriz; Vargas, Ingrid; Coderch, Jordi; Calero, Sebastià; Cots, Francesc; Abizanda, Mercè; Farré, Joan; Llopart, Josep Ramon; Colomés, Lluís; Vázquez, María Luisa
2015-08-13
Coordination across levels of care is becoming increasingly important due to rapid advances in technology, high specialisation and changes in the organization of healthcare services; to date, however, the development of indicators to evaluate coordination has been limited. The aim of this study is to develop and test a set of indicators to comprehensively evaluate clinical coordination across levels of care. A systematic review of literature was conducted to identify indicators of clinical coordination across levels of care. These indicators were analysed to identify attributes of coordination and classified accordingly. They were then discussed within an expert team and adapted or newly developed, and their relevance, scientific soundness and feasibility were examined. The indicators were tested in three healthcare areas of the Catalan health system. 52 indicators were identified addressing 11 attributes of clinical coordination across levels of care. The final set consisted of 21 output indicators. Clinical information transfer is evaluated based on information flow (4) and the adequacy of shared information (3). Clinical management coordination indicators evaluate care coherence through diagnostic testing (2) and medication (1), provision of care at the most appropriate level (2), completion of diagnostic process (1), follow-up after hospital discharge (4) and accessibility across levels of care (4). The application of indicators showed differences in the degree of clinical coordination depending on the attribute and area. A set of rigorous and scientifically sound measures of clinical coordination across levels of care were developed based on a literature review and discussion with experts. This set of indicators comprehensively address the different attributes of clinical coordination in main transitions across levels of care. It could be employed to identify areas in which health services can be improved, as well as to measure the effect of efforts to improve clinical coordination in healthcare organizations.
On a New Theory of the System of Reference
NASA Astrophysics Data System (ADS)
Kalanov, Temur Z.
2003-04-01
A new theory of the system of reference is suggested. It represents the new point of view which has arisen from the critical analysis of the foundations of physics (in particular, the theory of relativity and quantum mechanics), mathematics, cosmology and philosophy. The main idea following from the analysis is that the correct concept of system of reference represents a key to comprehension of many basic logic errors which are in modern physics. The starting point of the theory is represented by the philosophical (dialectical materialistic) principles, in particular, the gnosiological principle. (The gnosiological principle is briefly formulated as follows. The purpose of a science is to know the laws of the Nature. The law is a form of scientific knowledge of the essence and the phenomenon. The essence is the internal basis of the phenomenon, and the phenomenon is the manifestation of the essence. Human practice is a basis of knowledge and a criterion of truth). These principles lead to the following statements. (1) The reality is the dialectical unity of the opposites: the objective reality and the non-objective (subjective) reality. (2) The system mankind + means of knowledge belongs to the subjective reality and is called system of reference. In this wide sense, the system of reference is the universal informational gnostic basis (i.e. the system consisting of natural objects and processes, of constructed devices and instruments, of sum of human knowledge and skills) created and used by mankind for the purpose of knowledge of the world. (3) The opposites are bounds of each other. Hence, the principle of objectivity of the physical laws is formulated as follows: the objective physical laws must not contain mentions of system of reference (in particular, references to procedure of measurement or of calculation). (4) The main informational property of the unitary system set of researches physical objects + system of reference is that the system of reference determines (measures, calculates) the parameters of the subsystem set of researched physical objects (for example, the coordinates x_M, y_M, zM of the object M); the parameters characterize the system of reference (for example, the system of coordinates). (5) The main gnostic property of the unitary system set of researches physical objects + system of reference is that the system of reference defines (formulates) the physical laws (i.e. creates the theories); the physical laws characterize the system of reference. (6) The parameters which take on values independently of existence of the researched physical objects characterize the system of reference. For example, the clock C, a part of the system of reference S, determines (but it does not measure!) the time t_C; the time tC characterizes the clock C. If all clocks have been synchronized, the universal time tS characterizes the system of reference S. (7) Researched physical object M and a clock are mutually independent objects. Hence, the coordinates x_M, y_M, zM and the time tS are mutually independent parameters. (8) The informational one-to-one correspondence between motion of object M and physical clock-process in clock is established (is defined) by man. For example, it has a form: dx_M/dtS ≡ v_x_M. Consequences: (a) information about the world is an ordered information because the system of reference S is an ordered and universal system. This information is an objective one if it does not depend on a system of reference; (b) mathematical operations on physical quantities with the coordinates and with the time are allowed by the laws of logic because the set of researches physical objects + system of reference is a unitary system; (c) the principle of existence and of transformation of coordinates: there are no coordinates and no transformation of coordinates in general, and there exist the coordinates x_M, y_M, zM and transformation of the coordinates x_M, y_M, zM of the object M only; (d) the special and general theories of relativity are an erroneous theories because their foundations, firstly, do not satisfy the principle of objectivity of the physical laws, secondly, they contradict the principle of transformation of coordinates and, thirdly, they assume mutual dependence between the researched physical object and a clock (i.e. between coordinates and time); (e) quantum mechanics does not satisfy the principle of objectivity of the physical laws.
Space Station Application of Simulator-Developed Aircrew Coordination and Performance Measures
NASA Technical Reports Server (NTRS)
Murphy, Miles
1985-01-01
This paper summarizes a study in progress at NASA/Ames Research Center to develop measures of aircrew coordination and decision-making factors and to relate them to flight task performance, that is, to crew and system performance measures. The existence of some similar interpersonal process and task performance requirements suggests a potential application of these methods in space station crew research -- particularly research conducted in ground-based mock-ups. The secondary objective of this study should also be of interest: to develop information on crew process and performance for application in developing crew training programs.
Hu, Qinglei; Zhang, Jian
2015-01-01
This paper investigates finite-time relative position coordinated tracking problem by output feedback for spacecraft formation flying without velocity measurement. By employing homogeneous system theory, a finite-time relative position coordinated tracking controller by state feedback is firstly developed, where the desired time-varying trajectory given in advance can be tracked by the formation. Then, to address the problem of lack of velocity measurements, a finite-time output feedback controller is proposed by involving a novel filter to recover unknown velocity information in a finite time. Rigorous proof shows that the proposed control law ensures global stability and guarantees the position of spacecraft formation to track a time-varying reference in finite time. Finally, simulation results are presented to illustrate the performance of the proposed controller. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.
Reformulation of the relativistic conversion between coordinate time and atomic time
NASA Technical Reports Server (NTRS)
Thomas, J. B.
1975-01-01
The relativistic conversion between coordinate time and atomic time is reformulated to allow simpler time calculations relating analysis in solar system barycentric coordinates (using coordinate time) with earth-fixed observations (measuring 'earth-bound' proper time or atomic time). After an interpretation in terms of relatively well-known concepts, this simplified formulation, which has a rate accuracy of about 10 to the minus 15th, is used to explain the conventions required in the synchronization of a worldwide clock network and to analyze two synchronization techniques - portable clocks and radio interferometry. Finally, pertinent experimental tests of relativity are briefly discussed in terms of the reformulated time conversion.
Quantification and visualization of coordination during non-cyclic upper extremity motion.
Fineman, Richard A; Stirling, Leia A
2017-10-03
There are many design challenges in creating at-home tele-monitoring systems that enable quantification and visualization of complex biomechanical behavior. One such challenge is robustly quantifying joint coordination in a way that is intuitive and supports clinical decision-making. This work defines a new measure of coordination called the relative coordination metric (RCM) and its accompanying normalization schemes. RCM enables quantification of coordination during non-constrained discrete motions. Here RCM is applied to a grasping task. Fifteen healthy participants performed a reach, grasp, transport, and release task with a cup and a pen. The measured joint angles were then time-normalized and the RCM time-series were calculated between the shoulder-elbow, shoulder-wrist, and elbow-wrist. RCM was normalized using four differing criteria: the selected joint degree of freedom, angular velocity, angular magnitude, and range of motion. Percent time spent in specified RCM ranges was used asa composite metric and was evaluated for each trial. RCM was found to vary based on: (1) chosen normalization scheme, (2) the stage within the task, (3) the object grasped, and (4) the trajectory of the motion. The RCM addresses some of the limitations of current measures of coordination because it is applicable to discrete motions, does not rely on cyclic repetition, and uses velocity-based measures. Future work will explore clinically relevant differences in the RCM as it is expanded to evaluate different tasks and patient populations. Copyright © 2017. Published by Elsevier Ltd.
Graetz, Ilana; Reed, Mary; Shortell, Stephen M; Rundall, Thomas G; Bellows, Jim; Hsu, John
2014-12-01
Care for patients with chronic conditions often requires coordination between multiple physicians and delivery sites. Electronic Health Record (EHR) use could improve care quality and efficiency in part by facilitating care coordination. We examined the association between EHR use and clinician perceptions of care coordination for patients transferred across clinicians and delivery sites. Repeated surveys of primary care clinicians during the staggered implementation of an outpatient EHR (2005-2008), followed by an integrated inpatient EHR (2006-2010). We measured the association between EHR use stages (no use, outpatient EHR only, and integrated inpatient-outpatient EHR) and care coordination using logistic regression, adjusting for clinician characteristics, study year, and medical center. Adult primary care clinicians in a large Integrated Delivery System. Three measures of clinician-reported care coordination for patient care transferred across clinicians (eg, from specialist to primary care team) and across delivery sites (eg, from the hospital to outpatient care). Outpatient EHR use was associated with higher reports of access to complete and timely clinical information and higher agreement on clinician roles and responsibilities for patients transferred across clinicians, but not for patients transferred across delivery sites. Use of the integrated outpatient-inpatient EHR was associated with higher reports of access to timely and complete clinical information, clinician agreement on the patient's treatment plan for patients transferred across delivery sites, and with all coordination measures for patients transferred across clinicians. Use of an integrated EHR with health information exchange across delivery settings improved patient care coordination.
Bilateral assessment of functional tasks for robot-assisted therapy applications
Wang, Sarah; Bai, Ping; Strachota, Elaine; Tchekanov, Guennady; Melbye, Jeff; McGuire, John
2011-01-01
This article presents a novel evaluation system along with methods to evaluate bilateral coordination of arm function on activities of daily living tasks before and after robot-assisted therapy. An affordable bilateral assessment system (BiAS) consisting of two mini-passive measuring units modeled as three degree of freedom robots is described. The process for evaluating functional tasks using the BiAS is presented and we demonstrate its ability to measure wrist kinematic trajectories. Three metrics, phase difference, movement overlap, and task completion time, are used to evaluate the BiAS system on a bilateral symmetric (bi-drink) and a bilateral asymmetric (bi-pour) functional task. Wrist position and velocity trajectories are evaluated using these metrics to provide insight into temporal and spatial bilateral deficits after stroke. The BiAS system quantified movements of the wrists during functional tasks and detected differences in impaired and unimpaired arm movements. Case studies showed that stroke patients compared to healthy subjects move slower and are less likely to use their arm simultaneously even when the functional task requires simultaneous movement. After robot-assisted therapy, interlimb coordination spatial deficits moved toward normal coordination on functional tasks. PMID:21881901
NASA Astrophysics Data System (ADS)
Vershkov, A. N.; Petrovskaya, M. S.
2016-11-01
The series in ellipsoidal harmonics for derivatives of the Earth's gravity potential are used only on the reference ellipsoid enveloping the Earth due to their very complex mathematical structure. In the current study, the series in ellipsoidal harmonics are constructed for first- and second-order derivatives of the potential at satellite altitudes; their structure is similar to the series on the reference ellipsoid. The point P is chosen at a random satellite altitude; then, the ellipsoid of revolution is described, which passes through this point and is confocal to the reference ellipsoid. An object-centered coordinate system with the origin at the point P is considered. Using a sequence of transformations, the nonsingular series in ellipsoidal harmonics is constructed for first and second derivatives of the potential in the object-centered coordinate system. These series can be applied to develop a model of the Earth's potential, based on combined use of surface gravitational force measurements, data on the satellite orbital position, its acceleration, or measurements of the gravitational force gradients of the first and second order. The technique is applicable to any other planet of the Solar System.
[Coordination among healthcare levels: systematization of tools and measures].
Terraza Núñez, Rebeca; Vargas Lorenzo, Ingrid; Vázquez Navarrete, María Luisa
2006-01-01
Improving healthcare coordination is a priority in many healthcare systems, particularly in chronic health problems in which a number of professionals and services intervene. There is an abundance of coordination strategies and mechanisms that should be systematized so that they can be used in the most appropriate context. The present article aims to analyse healthcare coordination and its instruments using the organisational theory. Coordination mechanisms can be classified according to two basic processes used to coordinate activities: programming and feedback. The optimal combination of mechanisms will depend on three factors: the degree to which healthcare activities are differentiated, the volume and type of interdependencies, and the level of uncertainty. Historically, healthcare services have based coordination on skills standardization and, most recently, on processes standardization, through clinical guidelines, maps, and plans. Their utilisation is unsatisfactory in chronic diseases involving intervention by several professionals with reciprocal interdependencies, variability in patients' response to medical interventions, and a large volume of information to be processed. In this case, mechanisms based on feedback, such as working groups, linking professionals and vertical information systems, are more effective. To date, evaluation of healthcare coordination has not been conducted systematically, using structure, process and results indicators. The different strategies and instruments have been applied mainly to long-term care and mental health and one of the challenges to healthcare coordination is to extend and evaluate their use throughout the healthcare continuum.
A Rapid Method to Achieve Aero-Engine Blade Form Detection
Sun, Bin; Li, Bing
2015-01-01
This paper proposes a rapid method to detect aero-engine blade form, according to the characteristics of an aero-engine blade surface. This method first deduces an inclination error model in free-form surface measurements based on the non-contact laser triangulation principle. Then a four-coordinate measuring system was independently developed, a special fixture was designed according to the blade shape features, and a fast measurement of the blade features path was planned. Finally, by using the inclination error model for correction of acquired data, the measurement error that was caused by tilt form is compensated. As a result the measurement accuracy of the Laser Displacement Sensor was less than 10 μm. After the experimental verification, this method makes full use of optical non-contact measurement fast speed, high precision and wide measuring range of features. Using a standard gauge block as a measurement reference, the coordinate system conversion data is simple and practical. It not only improves the measurement accuracy of the blade surface, but also its measurement efficiency. Therefore, this method increases the value of the measurement of complex surfaces. PMID:26039420
A rapid method to achieve aero-engine blade form detection.
Sun, Bin; Li, Bing
2015-06-01
This paper proposes a rapid method to detect aero-engine blade form, according to the characteristics of an aero-engine blade surface. This method first deduces an inclination error model in free-form surface measurements based on the non-contact laser triangulation principle. Then a four-coordinate measuring system was independently developed, a special fixture was designed according to the blade shape features, and a fast measurement of the blade features path was planned. Finally, by using the inclination error model for correction of acquired data, the measurement error that was caused by tilt form is compensated. As a result the measurement accuracy of the Laser Displacement Sensor was less than 10 μm. After the experimental verification, this method makes full use of optical non-contact measurement fast speed, high precision and wide measuring range of features. Using a standard gauge block as a measurement reference, the coordinate system conversion data is simple and practical. It not only improves the measurement accuracy of the blade surface, but also its measurement efficiency. Therefore, this method increases the value of the measurement of complex surfaces.
Goddard trajectory determination subsystem: Mathematical specifications
NASA Technical Reports Server (NTRS)
Wagner, W. E. (Editor); Velez, C. E. (Editor)
1972-01-01
The mathematical specifications of the Goddard trajectory determination subsystem of the flight dynamics system are presented. These specifications include the mathematical description of the coordinate systems, dynamic and measurement model, numerical integration techniques, and statistical estimation concepts.
Coordinate metrology of a primary surface composite panel from the Large Millimeter Telescope
NASA Astrophysics Data System (ADS)
Gale, David M.; Lucero Álvarez, Maribel; Cabrera Cuevas, Lizeth; Leon-Huerta, Andrea; Arizmendi Reyes, Edgar; Icasio Hernández, Octavio; Castro Santos, David; Hernández Ríos, Emilio; Tecuapetla Sosa, Esteban; Tzile Torres, Carlos; Viliesid Alonso, Miguel
2016-07-01
The Large Millimeter Telescope (LMT) is a single-dish fully-steerable radio telescope presently operating with a 32.5 m parabolic primary reflector, in the process of extension to 50 m. The project is managed by the Instituto Nacional de Astrofísica, Óptica y Electrónica (INAOE) in México, and the University of Massachusetts Amherst, USA. A laminated surface panel from the LMT primary reflector has been subjected to a surface measurement assay at Mexico's National Metrology Center (CENAM). Data obtained using a coordinate measuring machine and laser tracker owned by CENAM is compared with measurements using an identical model laser tracker and the photogrammetry technique, the latter systems owned and operated by the LMT. All measurements were performed within the controlled metrology environment at CENAM. The measurement exercise is intended to prepare the groundwork for converting this spare surface panel into a calibrated work-piece. The establishment of a calibrated work-piece provides quality assurance for metrology through measurement traceability. It also simplifies the evaluation of measurement uncertainty for coordinate metrology procedures used by the LMT project during reflector surface qualification.
Carlisle, Keith [Discovery Bay, CA
2003-04-08
An apparatus and method is utilized to measure relative rigid body motion between two bodies by measuring linear motion in the principal axis and linear motion in an orthogonal axis. From such measurements it is possible to obtain displacement, departure from straightness, and angular displacement from the principal axis of a rigid body.
Linux OS Jitter Measurements at Large Node Counts using a BlueGene/L
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, Terry R; Tauferner, Mr. Andrew; Inglett, Mr. Todd
2010-01-01
We present experimental results for a coordinated scheduling implementation of the Linux operating system. Results were collected on an IBM Blue Gene/L machine at scales up to 16K nodes. Our results indicate coordinated scheduling was able to provide a dramatic improvement in scaling performance for two applications characterized as bulk synchronous parallel programs.
Liss, David T; Chubak, Jessica; Anderson, Melissa L; Saunders, Kathleen W; Tuzzio, Leah; Reid, Robert J
2011-01-01
Care coordination is increasingly recognized as a necessary element of high-quality, patient-centered care. This study investigated (1) the association between care coordination and continuity of primary care, and (2) differences in this association by level of specialty care use. We conducted a cross-sectional study of Medicare enrollees with select chronic conditions in an integrated health care delivery system in Washington State. We collected survey information on patient experiences and automated health care utilization data for 1 year preceding survey completion. Coordination was defined by the coordination measure from the short form of the Ambulatory Care Experiences Survey (ACES). Continuity was measured by primary care visit concentration. Patients who had 10 or more specialty care visits were classified as high users. Linear regression was used to estimate the association between coordination and continuity, controlling for potential confounders and clustering within clinicians. We used a continuity-by-specialty interaction term to determine whether the continuity-coordination association was modified by high specialty care use. Among low specialty care users, an increase of 1 standard deviation (SD) in continuity was associated with an increase of 2.71 in the ACES coordination scale (P <.001). In high specialty care users, we observed no association between continuity and reported coordination (P= .77). High use of specialty care may strain the ability of primary care clinicians to coordinate care effectively. Future studies should investigate care coordination interventions that allow for appropriate specialty care referrals without diminishing the ability of primary care physicians to manage overall patient care.
Object detection system using SPAD proximity detectors
NASA Astrophysics Data System (ADS)
Stark, Laurence; Raynor, Jeffrey M.; Henderson, Robert K.
2011-10-01
This paper presents an object detection system based upon the use of multiple single photon avalanche diode (SPAD) proximity sensors operating upon the time-of-flight (ToF) principle, whereby the co-ordinates of a target object in a coordinate system relative to the assembly are calculated. The system is similar to a touch screen system in form and operation except that the lack of requirement of a physical sensing surface provides a novel advantage over most existing touch screen technologies. The sensors are controlled by FPGA-based firmware and each proximity sensor in the system measures the range from the sensor to the target object. A software algorithm is implemented to calculate the x-y coordinates of the target object based on the distance measurements from at least two separate sensors and the known relative positions of these sensors. Existing proximity sensors were capable of determining the distance to an object with centimetric accuracy and were modified to obtain a wide field of view in the x-y axes with low beam angle in z in order to provide a detection area as large as possible. Design and implementation of the firmware, electronic hardware, mechanics and optics are covered in the paper. Possible future work would include characterisation with alternative designs of proximity sensors, as this is the component which determines the highest achievable accur1acy of the system.
Gómez-Polo, Cristina; Gómez-Polo, Miguel; Celemín Viñuela, Alicia; Martínez Vázquez de Parga, Juan Antonio
2015-03-01
The 3D-Master System comprises 26 physical shade tabs and intermediate shades. Determining the relationship among all the groups of lightness, chroma, and hue of the 3D-Master System (Vita Zahnfabrik) and the L*, C*, and h* coordinates is important, because according to the manufacturer, 2 Toothguide 3D-Master shades need to be mixed in a 50:50 ratio to create an intermediate shade. The purpose of the study was to relate the lightness, chroma, and hue groups of the 3D-Master System with the polar coordinates of the CIELAB chromatic space, L*, C*, and h*, and to quantify the shades tabs and intermediate shades of the 3D-Master System according to color coordinates. The middle third of the facial surface of a natural maxillary central incisor was measured with an Easyshade Compact spectrophotometer (Vita Zahnfabrik) in 1361 Spanish participants aged between 16 and 89 years. Natural tooth color was recorded in the 3D-Master nomenclature and in the CIE L*, C*, and h* coordinates system. The program used for the present descriptive statistical analysis of the results was SAS 9.1.3. In the L* variable, the minimum was found at 47.0 and the maximum at 91.3. In the C* variable, the minimum was found at 5.9 and the maximum at 49.8, while for h*, the minimum was 67.5 degrees and the maximum 112.0 degrees. Despite the limitations of this study, the 3D-Master System was found to be arranged according to L*, C*, and h* coordinates in groups of lightness, chroma, and hue. The corresponding groups of lightness, chroma, and hue can be estimated on the basis of L*, C*, and h* coordinates. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Method for measuring target rotation angle by theodolites
NASA Astrophysics Data System (ADS)
Sun, Zelin; Wang, Zhao; Zhai, Huanchun; Yang, Xiaoxu
2013-05-01
To overcome the disadvantage of the current measurement methods using theodolites in an environment with shock and long working hours and so on, this paper proposes a new method for 3D coordinate measurement that is based on an immovable measuring coordinate system. According to the measuring principle, the mathematics model is established and the measurement uncertainty is analysed. The measurement uncertainty of the new method is a function of the theodolite observation angles and their uncertainty, and can be reduced by optimizing the theodolites’ placement. Compared to other methods, this method allows the theodolite positions to be changed in the measuring process, and mutual collimation between the theodolites is not required. The experimental results show that the measurement model and the optimal placement principle are correct, and the measurement error is less than 0.01° after optimizing the theodolites’ placement.
Changes in measured vector magnetic fields when transformed into heliographic coordinates
NASA Technical Reports Server (NTRS)
Hagyard, M. J.
1987-01-01
The changes that occur in measured magnetic fields when they are transformed into a heliographic coordinate system are investigated. To carry out this investigation, measurements of the vector magnetic field of an active region that was observed at 1/3 the solar radius from disk center are taken, and the observed field is transformed into heliographic coordinates. Differences in the calculated potential field that occur when the heliographic normal component of the field is used as the boundary condition rather than the observed line-of-sight component are also examined. The results of this analysis show: (1) that the observed fields of sunspots more closely resemble the generally accepted picture of the distribution of umbral fields if they are displayed in heliographic coordinates; (2) that the differences in the potential calculations are less than 200 G in field strength and 20 deg in field azimuth outside sunspots; and (3) that differences in the two potential calculations in the sunspot areas are no more than 400 G in field strength but range from 60 to 80 deg in field azimuth in localized umbral areas.
Reorganization of the human central nervous system.
Schalow, G; Zäch, G A
2000-10-01
The key strategies on which the discovery of the functional organization of the central nervous system (CNS) under physiologic and pathophysiologic conditions have been based included (1) our measurements of phase and frequency coordination between the firings of alpha- and gamma-motoneurons and secondary muscle spindle afferents in the human spinal cord, (2) knowledge on CNS reorganization derived upon the improvement of the functions of the lesioned CNS in our patients in the short-term memory and the long-term memory (reorganization), and (3) the dynamic pattern approach for re-learning rhythmic coordinated behavior. The theory of self-organization and pattern formation in nonequilibrium systems is explicitly related to our measurements of the natural firing patterns of sets of identified single neurons in the human spinal premotor network and re-learned coordinated movements following spinal cord and brain lesions. Therapy induced cell proliferation, and maybe, neurogenesis seem to contribute to the host of structural changes during the process of re-learning of the lesioned CNS. So far, coordinated functions like movements could substantially be improved in every of the more than 100 patients with a CNS lesion by applying coordination dynamic therapy. As suggested by the data of our patients on re-learning, the human CNS seems to have a second integrative strategy for learning, re-learning, storing and recalling, which makes an essential contribution of the functional plasticity following a CNS lesion. A method has been developed by us for the simultaneous recording with wire electrodes of extracellular action potentials from single human afferent and efferent nerve fibres of undamaged sacral nerve roots. A classification scheme of the nerve fibres in the human peripheral nervous system (PNS) could be set up in which the individual classes of nerve fibres are characterized by group conduction velocities and group nerve fibre diameters. Natural impulse patterns of several identified single afferent and efferent nerve fibres (motoneuron axons) were extracted from multi-unit impulse patterns, and human CNS functions could be analyzed under physiologic and pathophysiologic conditions. With our discovery of premotor spinal oscillators it became possible to judge upon CNS neuronal network organization based on the firing patterns of these spinal oscillators and their driving afferents. Since motoneurons fire occasionally for low activation and oscillatory for high activation, the coherent organization of subnetworks to generate macroscopic function is very complex and for the time being, may be best described by the theory of coordination dynamics. Since oscillatory firing has also been observed by us in single motor unit firing patterns measured electromyographically, it seems possible to follow up therapeutic intervention in patients with spinal cord and brain lesions not only based on the activity levels and phases of motor programs during locomotion but also based on the physiologic and pathophysiologic firing patterns and recruitment of spinal oscillators. The improvement of the coordination dynamics of the CNS can be partly measured directly by rhythmicity upon the patient performing rhythmic movements coordinated up to milliseconds. Since rhythmic dynamic, coordinated, stereotyped movements are mainly located in the spinal cord and only little supraspinal drive is necessary to initiate, maintain, and terminate them, rhythmic, dynamic, coordinated movements were used in therapy to enforce reorganization of the lesioned CNS by improving the self-organization and relative coordination of spinal oscillators (and their interactions with occasionally firing motoneurons) which became pathologic in their firing following CNS lesion. Paraparetic, tetraparetic spinal cord and brain-lesioned patients re-learned running and other movements by an oscillator formation and coordination dynamic therapy. Our development in neurorehabilitation is in accordance with those of theoretical and computational neurosciences which deal with the self-organization of neuronal networks. In particular, jumping on a springboard 'in-phase' and in 'anti-phase' to re-learn phase relations of oscillator coupling can be understood in the framework of the Haken-Kelso-Bunz coordination dynamic model. By introducing broken symmetry, intention, learning and spasticity in the landscape of the potential function of the integrated CNS activity, the change in self-organization becomes understandable. Movement patterns re-learned by oscillator formation and coordination dynamic therapy evolve from reorganization and regeneration of the lesioned CNS by cooperative and competitive interplay between intrinsic coordination dynamics, extrinsic therapy related inputs with physiologic re-afferent input, including intention, motivation, supervised learning, interpersonal coordination, and genetic constraints including neurogenesis. (ABSTRACT TRUNCATED)
NASA Astrophysics Data System (ADS)
Feng, Shijie; Chen, Qian; Zuo, Chao; Sun, Jiasong; Yu, Shi Ling
2014-10-01
Optical three-dimensional (3-D) profilometry is gaining increasing attention for its simplicity, flexibility, high accuracy, and non-contact nature. Recent advances in imaging sensors and digital projection technology further its progress in high-speed, real-time applications, enabling 3-D shapes reconstruction of moving objects and dynamic scenes. However, the camera lens is never perfect and the lens distortion does influence the accuracy of the measurement result, which is often overlooked in the existing real-time 3-D shape measurement systems. To this end, here we present a novel high-speed real-time 3-D coordinates measuring technique based on fringe projection with the consideration of the camera lens distortion. A pixel mapping relation between a distorted image and a corrected one is pre-determined and stored in computer memory for real-time fringe correction. The out-of-plane height is obtained firstly and the acquisition for the two corresponding in-plane coordinates follows on the basis of the solved height. Besides, a method of lookup table (LUT) is introduced as well for fast data processing. Our experimental results reveal that the measurement error of the in-plane coordinates has been reduced by one order of magnitude and the accuracy of the out-plane coordinate been tripled after the distortions being eliminated. Moreover, owing to the generated LUTs, a 3-D reconstruction speed of 92.34 frames per second can be achieved.
Naval Biodynamics Laboratory 1993 Command History
1993-01-01
position and alignment, camera optical calibration, photo target position, and standard anatomical coordinate systems based upon X-rays of each HRV...safety range. Before, during, and after each sled run, a physiological data acquisition system is used to collect and analyze physiological measurements ...experimental devices. It is also responsible for the configuring of field data measuring and acquisition systems for use aboard ships or at other field
NASA Technical Reports Server (NTRS)
Deker, H.
1971-01-01
The West German tracking stations are equipped with ballistic cameras. Plate measurement and plate reduction must therefore follow photogrammetric methods. Approximately 100 star positions and 200 satellite positions are measured on each plate. The mathematical model for spatial rotation of the bundle of rays is extended by including terms for distortion and internal orientation of the camera as well as by providing terms for refraction which are computed for the measured coordinates of the star positions on the plate. From the measuring accuracy of the plate coordinates it follows that the timing accuracy for the exposures has to be about one millisecond, in order to obtain a homogeneous system.
A novel validation and calibration method for motion capture systems based on micro-triangulation.
Nagymáté, Gergely; Tuchband, Tamás; Kiss, Rita M
2018-06-06
Motion capture systems are widely used to measure human kinematics. Nevertheless, users must consider system errors when evaluating their results. Most validation techniques for these systems are based on relative distance and displacement measurements. In contrast, our study aimed to analyse the absolute volume accuracy of optical motion capture systems by means of engineering surveying reference measurement of the marker coordinates (uncertainty: 0.75 mm). The method is exemplified on an 18 camera OptiTrack Flex13 motion capture system. The absolute accuracy was defined by the root mean square error (RMSE) between the coordinates measured by the camera system and by engineering surveying (micro-triangulation). The original RMSE of 1.82 mm due to scaling error was managed to be reduced to 0.77 mm while the correlation of errors to their distance from the origin reduced from 0.855 to 0.209. A simply feasible but less accurate absolute accuracy compensation method using tape measure on large distances was also tested, which resulted in similar scaling compensation compared to the surveying method or direct wand size compensation by a high precision 3D scanner. The presented validation methods can be less precise in some respects as compared to previous techniques, but they address an error type, which has not been and cannot be studied with the previous validation methods. Copyright © 2018 Elsevier Ltd. All rights reserved.
Coordinated ASCA/EUVE/XTE Observations of Algol
NASA Technical Reports Server (NTRS)
Stern, Robert A.
1997-01-01
EUVE, Advanced Satellite for Cosmology and Astrophysics (ASCA), and X-ray Timing Explorer (XTE) observed the eclipsing binary Algol (Beta Per) from 1-7 Feb 1996. The coordinated observation covered approx. 2 binary orbits of the system, with a net exposure of approx. 160 ksec for EUVE, 40 ksec for ASCA (in 4 pointings), and 90 ksec for XTE (in 45 pointings). We discuss results of modeling the combined EUVE, ASCA, and XTE data using continuous differential emission measure distributions, and provide constraints on the abundance in the Algol system.
NASA Technical Reports Server (NTRS)
Tappa, M. J.; Mills, R. D.; Ware, B.; Simon, J. I.
2014-01-01
The isotopic compositions of elements are often used to characterize nucelosynthetic contributions in early Solar System objects. Coordinated multiple middle-mass elements with differing volatilities may provide information regarding the location of condensation of early Solar System solids. Here we detail new procedures that we have developed to make high-precision multi-isotope measurements of chromium and calcium using thermal ionization mass spectrometry, and characterize a suite of chondritic and terrestrial material including two fragments of the Chelyabinsk LL-chondrite.
Advantages of High Tolerance Measurements in Fusion Environments Applying Photogrammetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
T. Dodson, R. Ellis, C. Priniski, S. Raftopoulos, D. Stevens, M. Viola
2009-02-04
Photogrammetry, a state-of-the-art technique of metrology employing digital photographs as the vehicle for measurement, has been investigated in the fusion environment. Benefits of this high tolerance methodology include relatively easy deployment for multiple point measurements and deformation/distortion studies. Depending on the equipment used, photogrammetric systems can reach tolerances of 25 microns (0.001 in) to 100 microns (0.004 in) on a 3-meter object. During the fabrication and assembly of the National Compact Stellarator Experiment (NCSX) the primary measurement systems deployed were CAD coordinate-based computer metrology equipment and supporting algorithms such as both interferometer-aided (IFM) and absolute distance measurementbased (ADM) laser trackers,more » as well as portable Coordinate Measurement Machine (CMM) arms. Photogrammetry was employed at NCSX as a quick and easy tool to monitor coil distortions incurred during welding operations of the machine assembly process and as a way to reduce assembly downtime for metrology processes.« less
Local structural order and relaxation effects in metal-chalcogenide glasses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saleh, Z.M.
1990-01-01
Nuclear quadrupole resonance (NQR) and nuclear magnetic resonance (NMR) have been employed to study the local structural order and the relaxation mechanisms in metal-arsenic-chalcogenide glasses for metal concentrations within the glass forming region. The glass forming region in the Cu-As-S and Cu-As-se glassy systems extends approximately to 6 and 25 at. % copper, respectively. In the composition Cu[sub x](As[sub 2/5]Ch[sub 3/5])[sub 1[minus]x], where Ch = S or Se, there is evidence of dramatic changes in the local structure as copper is added to the system. One important change is the formation of As-As bonds which are absent in As[sub 2]Ch[submore » 3]. The [sup 75]As NQR measurements indicate that the density of these bonds increases with copper concentration x. These results are consistent with the predictions of a model proposed recently to explain the local structural order in glassy metal chalcogenides. While NQR data show that arsenic atoms are threefold coordinated, EXAFs measurements have shown that copper is fourfold coordinated within the glass forming ranges in both systems. The NMR measurements confirm this result and quantitatively determine the local environment around the copper nuclei. For the naturally occurring mineral luzonite (Cu[sub 3]AsS[sub 4]) copper is fourfold coordinated. The known structure of this mineral has been used as a guide to understanding the local structure in the glasses. Copper and arsenic nuclear relaxation measurements were used to study the dynamics of these systems. The temperature and frequency dependence of the spin-lattice and spin-spin relaxation times have been carefully measured to determine the relaxation mechanisms.« less
Model Deformation Measurements at NASA Langley Research Center
NASA Technical Reports Server (NTRS)
Burner, A. W.
1998-01-01
Only recently have large amounts of model deformation data been acquired in NASA wind tunnels. This acquisition of model deformation data was made possible by the development of an automated video photogrammetric system to measure the changes in wing twist and bending under aerodynamic load. The measurement technique is based upon a single view photogrammetric determination of two dimensional coordinates of wing targets with a fixed third dimensional coordinate, namely the spanwise location. A major consideration in the development of the measurement system was that use of the technique must not appreciably reduce wind tunnel productivity. The measurement technique has been used successfully for a number of tests at four large production wind tunnels at NASA and a dedicated system is nearing completion for a fifth facility. These facilities are the National Transonic Facility, the Transonic Dynamics Tunnel, and the Unitary Plan Wind Tunnel at NASA Langley, and the 12-FT Pressure Tunnel at NASA Ames. A dedicated system for the Langley 16-Foot Transonic Tunnel is scheduled to be used for the first time for a test in September. The advantages, limitations, and strategy of the technique as currently used in NASA wind tunnels are presented. Model deformation data are presented which illustrate the value of these measurements. Plans for further enhancements to the technique are presented.
Outline of a general theory of behavior and brain coordination.
Kelso, J A Scott; Dumas, Guillaume; Tognoli, Emmanuelle
2013-01-01
Much evidence suggests that dynamic laws of neurobehavioral coordination are sui generis: they deal with collective properties that are repeatable from one system to another and emerge from microscopic dynamics but may not (even in principle) be deducible from them. Nevertheless, it is useful to try to understand the relationship between different levels while all the time respecting the autonomy of each. We report a program of research that uses the theoretical concepts of coordination dynamics and quantitative measurements of simple, well-defined experimental model systems to explicitly relate neural and behavioral levels of description in human beings. Our approach is both top-down and bottom-up and aims at ending up in the same place: top-down to derive behavioral patterns from neural fields, and bottom-up to generate neural field patterns from bidirectional coupling between astrocytes and neurons. Much progress can be made by recognizing that the two approaches--reductionism and emergentism--are complementary. A key to understanding is to couch the coordination of very different things--from molecules to thoughts--in the common language of coordination dynamics. Copyright © 2012 Elsevier Ltd. All rights reserved.
Outline of a General Theory of Behavior and Brain Coordination
Kelso, J. A. Scott; Dumas, Guillaume; Tognoli, Emmanuelle
2012-01-01
Much evidence suggests that dynamic laws of neurobehavioral coordination are sui generis: they deal with collective properties that are repeatable from one system to another and emerge from microscopic dynamics but may not (even in principle) be deducible from them. Nevertheless, it is useful to try to understand the relationship between different levels while all the time respecting the autonomy of each. We report a program of research that uses the theoretical concepts of coordination dynamics and quantitative measurements of simple, well-defined experimental model systems to explicitly relate neural and behavioral levels of description in human beings. Our approach is both top-down and bottom-up and aims at ending up in the same place: top-down to derive behavioral patterns from neural fields, and bottom-up to generate neural field patterns from bidirectional coupling between astrocytes and neurons. Much progress can be made by recognizing that the two approaches —reductionism and emergentism— are complementary. A key to understanding is to couch the coordination of very different things —from molecules to thoughts— in the common language of coordination dynamics. PMID:23084845
Xu, Chang; Li, Siyi; Wang, Kui; Hou, Zengguang; Yu, Ningbo
2017-07-01
In neuro-rehabilitation after stroke, the conventional constrained induced movement therapy (CIMT) has been well-accepted. Existing bilateral trainings are mostly on mirrored symmetrical motion. However, complementary bilateral movements are dominantly involved in activities of daily living (ADLs), and functional bilateral therapies may bring better skill transfer from trainings to daily life. Neurophysiological evidence is also growing. In this work, we firstly introduce our bilateral arm training system realized with a haptic interface and a motion sensor, as well as the tasks that have been designed to train both the manipulation function of the paretic arm and coordination of bilateral upper limbs. Then, we propose quantitative measures for functional assessment of complementary bilateral training performance, including kinematic behavior indices, smoothness, submovement and bimanual coordination. After that, we describe the experiments with healthy subjects and the results with respect to these quantitative measures. Feasibility and sensitivity of the proposed indices were evaluated through comparison of unilateral and bilateral training outcomes. The proposed bilateral training system and tasks, as well as the quantitative measures, have been demonstrated effective for training and assessment of unilateral and bilateral arm functions.
[Raman spectroscopic study of binary PbO-TeO2 glasses].
Huang, Li; You, Jing-Lin; Chen, Hui; Jiang, Guo-Chang
2008-07-01
Raman spectra of lead tellurite glasses and their melts were measured. Results show that four coordinate tellurite units convert into three coordinate units with increasing the concentration of PbO, and the number of non-bridging oxygen bonds (NBO) increases accordingly in this system. Three spectral peaks in the high frequency range were assigned to stretching vibration of bridging oxygen in four coordinate tellurite units (Q(b)), stretching vibration of non-bridging oxygen in four coordinate tellurite units (Q(nb)) and in three coordinate tellurite units (T(nb)). The relative density of four coordinate structure units decreases and the three coordinate tellurite units considerably exist in tellurite glasses when the concentration of PbO > 50%. Besides, the Raman frequencies of the three species' peaks become blue-shifted because of the temperature induced crystallization at high temperature, and the peak intensities increase and the peaks sharpen. The peaks merge together and become much broader while the glass is heated above the melting point because of multiple microstructure units coexisting.
On-field mounting position estimation of a lidar sensor
NASA Astrophysics Data System (ADS)
Khan, Owes; Bergelt, René; Hardt, Wolfram
2017-10-01
In order to retrieve a highly accurate view of their environment, autonomous cars are often equipped with LiDAR sensors. These sensors deliver a three dimensional point cloud in their own co-ordinate frame, where the origin is the sensor itself. However, the common co-ordinate system required by HAD (Highly Autonomous Driving) software systems has its origin at the center of the vehicle's rear axle. Thus, a transformation of the acquired point clouds to car co-ordinates is necessary, and thereby the determination of the exact mounting position of the LiDAR system in car coordinates is required. Unfortunately, directly measuring this position is a time-consuming and error-prone task. Therefore, different approaches have been suggested for its estimation which mostly require an exhaustive test-setup and are again time-consuming to prepare. When preparing a high number of LiDAR mounted test vehicles for data acquisition, most approaches fall short due to time or money constraints. In this paper we propose an approach for mounting position estimation which features an easy execution and setup, thus making it feasible for on-field calibration.
Bischoff, Guido; Böröcz, Zoltan; Proll, Christian; Kleinheinz, Johannes; von Bally, Gert; Dirksen, Dieter
2007-08-01
Optical topometric 3D sensors such as laser scanners and fringe projection systems allow detailed digital acquisition of human body surfaces. For many medical applications, however, not only the current shape is important, but also its changes, e.g., in the course of surgical treatment. In such cases, time delays of several months between subsequent measurements frequently occur. A modular 3D coordinate measuring system based on the fringe projection technique is presented that allows 3D coordinate acquisition including calibrated color information, as well as the detection and visualization of deviations between subsequent measurements. In addition, parameters describing the symmetry of body structures are determined. The quantitative results of the analysis may be used as a basis for objective documentation of surgical therapy. The system is designed in a modular way, and thus, depending on the object of investigation, two or three cameras with different capabilities in terms of resolution and color reproduction can be utilized to optimize the set-up.
A feasibility study of hand kinematics for EVA analysis using magnetic resonance imaging
NASA Technical Reports Server (NTRS)
Dickenson, Reuben D.; Lorenz, Christine H.; Peterson, Steven W.; Strauss, Alvin M.; Main, John A.
1992-01-01
A new method for analyzing the kinematics of joint motion using magnetic resonance imaging (MRI) is described. The reconstruction of the metacarpalphalangeal joint of the left index finger into a 3D graphic display is shown. From the reconstructed volumetric images, measurements of the angles of movement of the applicable bones are obtained and processed by analyzing the screw motion of the joint. Landmark positions are chosen at distinctive locations of the joint at fixed image threshold intensity levels to ensure repeatability. The primarily 2D planar motion of this joint is then studied using a method of constructing coordinate systems using three or more points. A transformation matrix based on a world coordinate system describes the location and orientation of the local target coordinate system. The findings show the applicability of MRI to joint kinematics for gaining further knowledge of the hand-glove design for EVA.
Application of composite small calibration objects in traffic accident scene photogrammetry.
Chen, Qiang; Xu, Hongguo; Tan, Lidong
2015-01-01
In order to address the difficulty of arranging large calibration objects and the low measurement accuracy of small calibration objects in traffic accident scene photogrammetry, a photogrammetric method based on a composite of small calibration objects is proposed. Several small calibration objects are placed around the traffic accident scene, and the coordinate system of the composite calibration object is given based on one of them. By maintaining the relative position and coplanar relationship of the small calibration objects, the local coordinate system of each small calibration object is transformed into the coordinate system of the composite calibration object. The two-dimensional direct linear transformation method is improved based on minimizing the reprojection error of the calibration points of all objects. A rectified image is obtained using the nonlinear optimization method. The increased accuracy of traffic accident scene photogrammetry using a composite small calibration object is demonstrated through the analysis of field experiments and case studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schiller, Steven R.; Schwartz, Lisa C.
Demand-side energy efficiency (efficiency) represents a low-cost opportunity to reduce electricity consumption and demand and provide a wide range of non-energy benefits, including avoiding air pollution. Efficiency-related energy and non-energy impacts are determined and documented by implementing evaluation, measurement and verification (EM&V) systems. This technical brief describes efficiency EM&V coordination strategies that Western states can consider taking on together, outlines EM&V-related products that might be appropriate for multistate coordination, and identifies some implications of coordination. Coordinating efficiency EM&V activities can save both time and costs for state agencies and stakeholders engaged in efficiency activities and can be particularly beneficial formore » multiple states served by the same utility. First, the brief summarizes basic information on efficiency, its myriad potential benefits and EM&V for assessing those benefits. Second, the brief introduces the concept of multistate EM&V coordination in the context of assessing such benefits, including achievement of state and federal goals to reduce air pollutants.1 Next, the brief presents three coordination strategy options for efficiency EM&V: information clearinghouse/exchange, EM&V product development, and a regional energy efficiency tracking system platform. The brief then describes five regional EM&V products that could be developed on a multistate basis: EM&V reporting formats, database of consistent deemed electricity savings values, glossary of definitions and concepts, efficiency EM&V methodologies, and EM&V professional standards or accreditation processes. Finally, the brief discusses options for next steps that Western states can take to consider multistate coordination on efficiency EM&V. Appendices provide background information on efficiency and EM&V, as well as definitions and suggested resources on the covered topics. This brief is intended to inform state public utility commissions, boards for public and consumer-owned utilities, state energy offices and air agencies, and other organizations involved in discussions about the use of efficiency EM&V.« less
Functional connectivity in the neuromuscular system underlying bimanual coordination
de Vries, Ingmar E. J.; Daffertshofer, Andreas; Stegeman, Dick F.
2016-01-01
Neural synchrony has been suggested as a mechanism for integrating distributed sensorimotor systems involved in coordinated movement. To test the role of corticomuscular and intermuscular coherence in bimanual coordination, we experimentally manipulated the degree of coordination between hand muscles by varying the sensitivity of the visual feedback to differences in bilateral force. In 16 healthy participants, cortical activity was measured using EEG and muscle activity of the flexor pollicis brevis of both hands using high-density electromyography (HDsEMG). Using the uncontrolled manifold framework, coordination between bilateral forces was quantified by the synergy index RV in the time and frequency domain. Functional connectivity was assessed using corticomuscular coherence between muscle activity and cortical source activity and intermuscular coherence between bilateral EMG activity. The synergy index increased in the high coordination condition. RV was higher in the high coordination condition in frequencies between 0 and 0.5 Hz; for the 0.5- to 2-Hz frequency band, this pattern was inverted. Corticomuscular coherence in the beta band (16–30 Hz) was maximal in the contralateral motor cortex and was reduced in the high coordination condition. In contrast, intermuscular coherence was observed at 5–12 Hz and increased with bimanual coordination. Within-subject comparisons revealed a negative correlation between RV and corticomuscular coherence and a positive correlation between RV and intermuscular coherence. Our findings suggest two distinct neural pathways: 1) corticomuscular coherence reflects direct corticospinal projections involved in controlling individual muscles; and 2) intermuscular coherence reflects diverging pathways involved in the coordination of multiple muscles. PMID:27628205
Collection and processing of data from a phase-coherent meteor radar
NASA Technical Reports Server (NTRS)
Backof, C. A., Jr.; Bowhill, S. A.
1974-01-01
An analysis of the measurement accuracy requirement of a high resolution meteor radar for observing short period, atmospheric waves is presented, and a system which satisfies the requirements is described. A medium scale, real time computer is programmed to perform all echo recognition and coordinate measurement functions. The measurement algorithms are exercised on noisy data generated by a program which simulates the hardware system, in order to find the effects of noise on the measurement accuracies.
McConnell, K John; Renfro, Stephanie; Lindrooth, Richard C; Cohen, Deborah J; Wallace, Neal T; Chernew, Michael E
2017-03-01
In 2012 Oregon initiated an ambitious delivery system reform, moving the majority of its Medicaid enrollees into sixteen coordinated care organizations, a type of Medicaid accountable care organization. Using claims data, we assessed measures of access, appropriateness of care, utilization, and expenditures for five service areas (evaluation and management, imaging, procedures, tests, and inpatient facility care), comparing Oregon to the neighboring state of Washington. Overall, the transformation into coordinated care organizations was associated with a 7 percent relative reduction in expenditures across the sum of these services, attributable primarily to reductions in inpatient utilization. The change to coordinated care organizations also demonstrated reductions in avoidable emergency department visits and improvements in some measures of appropriateness of care, but also exhibited reductions in primary care visits, a potential area of concern. Oregon's coordinated care organizations could provide lessons for controlling health care spending for other state Medicaid programs. Project HOPE—The People-to-People Health Foundation, Inc.
A relativistic analysis of clock synchronization
NASA Technical Reports Server (NTRS)
Thomas, J. B.
1974-01-01
The relativistic conversion between coordinate time and atomic time is reformulated to allow simpler time calculations relating analysis in solar-system barycentric coordinates (using coordinate time) with earth-fixed observations (measuring earth-bound proper time or atomic time.) After an interpretation of terms, this simplified formulation, which has a rate accuracy of about 10 to the minus 15th power, is used to explain the conventions required in the synchronization of a world wide clock network and to analyze two synchronization techniques-portable clocks and radio interferometry. Finally, pertinent experiment tests of relativity are briefly discussed in terms of the reformulated time conversion.
Integrated calibration of multiview phase-measuring profilometry
NASA Astrophysics Data System (ADS)
Lee, Yeong Beum; Kim, Min H.
2017-11-01
Phase-measuring profilometry (PMP) measures per-pixel height information of a surface with high accuracy. Height information captured by a camera in PMP relies on its screen coordinates. Therefore, a PMP measurement from a view cannot be integrated directly to other measurements from different views due to the intrinsic difference of the screen coordinates. In order to integrate multiple PMP scans, an auxiliary calibration of each camera's intrinsic and extrinsic properties is required, in addition to principal PMP calibration. This is cumbersome and often requires physical constraints in the system setup, and multiview PMP is consequently rarely practiced. In this work, we present a novel multiview PMP method that yields three-dimensional global coordinates directly so that three-dimensional measurements can be integrated easily. Our PMP calibration parameterizes intrinsic and extrinsic properties of the configuration of both a camera and a projector simultaneously. It also does not require any geometric constraints on the setup. In addition, we propose a novel calibration target that can remain static without requiring any mechanical operation while conducting multiview calibrations, whereas existing calibration methods require manually changing the target's position and orientation. Our results validate the accuracy of measurements and demonstrate the advantages on our multiview PMP.
Pulsar timing and general relativity
NASA Technical Reports Server (NTRS)
Backer, D. C.; Hellings, R. W.
1986-01-01
Techniques are described for accounting for relativistic effects in the analysis of pulsar signals. Design features of instrumentation used to achieve millisecond accuracy in the signal measurements are discussed. The accuracy of the data permits modeling the pulsar physical characteristics from the natural glitches in the emissions. Relativistic corrections are defined for adjusting for differences between the pulsar motion in its spacetime coordinate system relative to the terrestrial coordinate system, the earth's motion, and the gravitational potentials of solar system bodies. Modifications of the model to allow for a binary pulsar system are outlined, including treatment of the system as a point mass. Finally, a quadrupole model is presented for gravitational radiation and techniques are defined for using pulsars in the search for gravitational waves.
A PLM-based automated inspection planning system for coordinate measuring machine
NASA Astrophysics Data System (ADS)
Zhao, Haibin; Wang, Junying; Wang, Boxiong; Wang, Jianmei; Chen, Huacheng
2006-11-01
With rapid progress of Product Lifecycle Management (PLM) in manufacturing industry, automatic generation of inspection planning of product and the integration with other activities in product lifecycle play important roles in quality control. But the techniques for these purposes are laggard comparing with techniques of CAD/CAM. Therefore, an automatic inspection planning system for Coordinate Measuring Machine (CMM) was developed to improve the automatization of measuring based on the integration of inspection system in PLM. Feature information representation is achieved based on a PLM canter database; measuring strategy is optimized through the integration of multi-sensors; reasonable number and distribution of inspection points are calculated and designed with the guidance of statistic theory and a synthesis distribution algorithm; a collision avoidance method is proposed to generate non-collision inspection path with high efficiency. Information mapping is performed between Neutral Interchange Files (NIFs), such as STEP, DML, DMIS, XML, etc., to realize information integration with other activities in the product lifecycle like design, manufacturing and inspection execution, etc. Simulation was carried out to demonstrate the feasibility of the proposed system. As a result, the inspection process is becoming simpler and good result can be got based on the integration in PLM.
Guiding Principles for Data Architecture to Support the Pathways Community HUB Model.
Zeigler, Bernard P; Redding, Sarah; Leath, Brenda A; Carter, Ernest L; Russell, Cynthia
2016-01-01
The Pathways Community HUB Model provides a unique strategy to effectively supplement health care services with social services needed to overcome barriers for those most at risk of poor health outcomes. Pathways are standardized measurement tools used to define and track health and social issues from identification through to a measurable completion point. The HUB use Pathways to coordinate agencies and service providers in the community to eliminate the inefficiencies and duplication that exist among them. Experience with the Model has brought out the need for better information technology solutions to support implementation of the Pathways themselves through decision-support tools for care coordinators and other users to track activities and outcomes, and to facilitate reporting. Here we provide a basis for discussing recommendations for such a data infrastructure by developing a conceptual model that formalizes the Pathway concept underlying current implementations. The main contribution is a set of core recommendations as a framework for developing and implementing a data architecture to support implementation of the Pathways Community HUB Model. The objective is to present a tool for communities interested in adopting the Model to learn from and to adapt in their own development and implementation efforts. Experience with the Community Health Access Project (CHAP) data base system (the core implementation of the Model) has identified several issues and remedies that have been developed to address these issues. Based on analysis of issues and remedies, we present several key features for a data architecture meeting the just mentioned recommendations. Presentation of features is followed by a practical guide to their implementation allowing an organization to consider either tailoring off-the-shelf generic systems to meet the requirements or offerings that are specialized for community-based care coordination. Looking to future extensions, we discuss the utility and prospects for an ontology to include care coordination in the Unified Medical Language System (UMLS) of the National Library of Medicine and other existing medical and nursing taxonomies. Pathways structures are an important principle, not only for organizing the care coordination activities, but also for structuring the data stored in electronic form in the conduct of such care. We showed how the proposed architecture encourages design of effective decision support systems for coordinated care and suggested how interested organizations can set about acquiring such systems. Although the presentation focuses on the Pathways Community HUB Model, the principles for data architecture are stated in generic form and are applicable to any health information system for improving care coordination services and population health.
Distributed sensor coordination for advanced energy systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tumer, Kagan
Motivation: The ability to collect key system level information is critical to the safe, efficient and reliable operation of advanced power systems. Recent advances in sensor technology have enabled some level of decision making directly at the sensor level. However, coordinating large numbers of sensors, particularly heterogeneous sensors, to achieve system level objectives such as predicting plant efficiency, reducing downtime or predicting outages requires sophisticated coordination algorithms. Indeed, a critical issue in such systems is how to ensure the interaction of a large number of heterogenous system components do not interfere with one another and lead to undesirable behavior. Objectivesmore » and Contributions: The long-term objective of this work is to provide sensor deployment, coordination and networking algorithms for large numbers of sensors to ensure the safe, reliable, and robust operation of advanced energy systems. Our two specific objectives are to: 1. Derive sensor performance metrics for heterogeneous sensor networks. 2. Demonstrate effectiveness, scalability and reconfigurability of heterogeneous sensor network in advanced power systems. The key technical contribution of this work is to push the coordination step to the design of the objective functions of the sensors, allowing networks of heterogeneous sensors to be controlled. By ensuring that the control and coordination is not specific to particular sensor hardware, this approach enables the design and operation of large heterogeneous sensor networks. In addition to the coordination coordination mechanism, this approach allows the system to be reconfigured in response to changing needs (e.g., sudden external events requiring new responses) or changing sensor network characteristics (e.g., sudden changes to plant condition). Impact: The impact of this work extends to a large class of problems relevant to the National Energy Technology Laboratory including sensor placement, heterogeneous sensor coordination, and sensor network control in advanced power systems. Each application has specific needs, but they all share the one crucial underlying problem: how to ensure that the interactions of a large number of heterogenous agents lead to coordinated system behavior. This proposal describes a new paradigm that addresses that very issue in a systematic way. Key Results and Findings: All milestones have been completed. Our results demonstrate that by properly shaping agent objective functions, we can develop large (up to 10,000 devices) heterogeneous sensor networks with key desirable properties. The first milestone shows that properly choosing agent-specific objective functions increases system performance by up to 99.9% compared to global evaluations. The second milestone shows evolutionary algorithms learn excellent sensor network coordination policies prior to network deployment, and these policies can be refined online once the network is deployed. The third milestone shows the resulting sensor networks networks are extremely robust to sensor noise, where networks with up to 25% sensor noise are capable of providing measurements with errors on the order of 10⁻³. The fourth milestone shows the resulting sensor networks are extremely robust to sensor failure, with 25% of the sensors in the system failing resulting in no significant performance losses after system reconfiguration.« less
A design of optical modulation system with pixel-level modulation accuracy
NASA Astrophysics Data System (ADS)
Zheng, Shiwei; Qu, Xinghua; Feng, Wei; Liang, Baoqiu
2018-01-01
Vision measurement has been widely used in the field of dimensional measurement and surface metrology. However, traditional methods of vision measurement have many limits such as low dynamic range and poor reconfigurability. The optical modulation system before image formation has the advantage of high dynamic range, high accuracy and more flexibility, and the modulation accuracy is the key parameter which determines the accuracy and effectiveness of optical modulation system. In this paper, an optical modulation system with pixel level accuracy is designed and built based on multi-points reflective imaging theory and digital micromirror device (DMD). The system consisted of digital micromirror device, CCD camera and lens. Firstly we achieved accurate pixel-to-pixel correspondence between the DMD mirrors and the CCD pixels by moire fringe and an image processing of sampling and interpolation. Then we built three coordinate systems and calculated the mathematic relationship between the coordinate of digital micro-mirror and CCD pixels using a checkerboard pattern. A verification experiment proves that the correspondence error is less than 0.5 pixel. The results show that the modulation accuracy of system meets the requirements of modulation. Furthermore, the high reflecting edge of a metal circular piece can be detected using the system, which proves the effectiveness of the optical modulation system.
Michinov, E; Olivier-Chiron, E; Rusch, E; Chiron, B
2008-03-01
There is an increasing awareness in the medical community that human factors are involved in effectiveness of anaesthesia teams. Communication and coordination between physicians and nurses seems to play a crucial role in maintaining a good level of performance under time pressure, particularly for anaesthesia teams, who are confronted with uncertainty, rapid changes in the environment, and multi-tasking. The aim of this study was to examine the relationship between a specific form of implicit coordination--the transactive memory system--and perceptions of team effectiveness and work attitudes such as job satisfaction and team identification. A cross-sectional study was conducted among 193 nurse and physician anaesthetists from eight French public hospitals. The questionnaire included some measures of transactive memory system (coordination, specialization, and credibility components), perception of team effectiveness, and work attitudes (Minnesota Job Satisfaction Questionnaire, team identification scale). The questionnaire was designed to be filled anonymously, asking only biographical data relating to sex, age, status, and tenure. Hierarchical multiple regression analyses revealed as predicted that transactive memory system predicted members' perceptions of team effectiveness, and also affective outcomes such as job satisfaction and team identification. Moreover, the results demonstrated that transactive memory processes, and especially the coordination component, were a better predictor of teamwork perceptions than socio-demographic (i.e. gender or status) or contextual variables (i.e. tenure and size of team). These findings provided empirical evidence of the existence of a transactive memory system among real anaesthesia teams, and highlight the need to investigate whether transactive memory is actually linked with objective measures of performance.
Ground mapping resolution accuracy of a scanning radiometer from a geostationary satellite.
Stremler, F G; Khalil, M A; Parent, R J
1977-06-01
Measures of the spatial and spatial rate (frequency) mapping of scanned visual imagery from an earth reference system to a spin-scan geostationary satellite are examined. Mapping distortions and coordinate inversions to correct for these distortions are formulated in terms of geometric transformations between earth and satellite frames of reference. Probabilistic methods are used to develop relations for obtainable mapping resolution when coordinate inversions are employed.
Effective Network Management via System-Wide Coordination and Optimization
2010-08-01
Srinath Sridhar, Matthew Streeter, Jimeng Sun, Michael Tschantz, Rangarajan Vasudevan, Vijay Vasude- van, Gaurav Veda, Shobha Venkataraman, Justin... Sharma and Byers [150] suggest the use of Bloom filters. While minimizing redundant measurements is a common high-level theme between cSamp and their...NSDI, 2004. [150] M. R. Sharma and J. W. Byers. Scalable Coordination Techniques for Distributed Network Monitoring. In Proc. of PAM, 2005. [151] S
The research on calibration methods of dual-CCD laser three-dimensional human face scanning system
NASA Astrophysics Data System (ADS)
Wang, Jinjiang; Chang, Tianyu; Ge, Baozhen; Tian, Qingguo; Yang, Fengting; Shi, Shendong
2013-09-01
In this paper, on the basis of considering the performance advantages of two-step method, we combines the stereo matching of binocular stereo vision with active laser scanning to calibrate the system. Above all, we select a reference camera coordinate system as the world coordinate system and unity the coordinates of two CCD cameras. And then obtain the new perspective projection matrix (PPM) of each camera after the epipolar rectification. By those, the corresponding epipolar equation of two cameras can be defined. So by utilizing the trigonometric parallax method, we can measure the space point position after distortion correction and achieve stereo matching calibration between two image points. Experiments verify that this method can improve accuracy and system stability is guaranteed. The stereo matching calibration has a simple process with low-cost, and simplifies regular maintenance work. It can acquire 3D coordinates only by planar checkerboard calibration without the need of designing specific standard target or using electronic theodolite. It is found that during the experiment two-step calibration error and lens distortion lead to the stratification of point cloud data. The proposed calibration method which combining active line laser scanning and binocular stereo vision has the both advantages of them. It has more flexible applicability. Theory analysis and experiment shows the method is reasonable.
Looman, Wendy S; Antolick, Megan; Cady, Rhonda G; Lunos, Scott A; Garwick, Ann E; Finkelstein, Stanley M
2015-01-01
The purpose of this study was to evaluate the effect of advanced practice registered nurse (APRN) telehealth care coordination for children with medical complexity (CMC) on family caregiver perceptions of health care. Families with CMC ages 2 to 15 years (N = 148) were enrolled in a three-armed, 30-month randomized controlled trial to test the effects of adding an APRN telehealth care coordination intervention to an existing specialized medical home for CMC. Satisfaction with health care was measured using items from the Consumer Assessment of Healthcare Providers and Systems survey at baseline and after 1 and 2 years. The intervention was associated with higher ratings on measures of the child's provider, provider communication, overall health care, and care coordination adequacy, compared with control subjects. Higher levels of condition complexity were associated with higher ratings of overall health care in some analyses. APRN telehealth care coordination for CMC was effective in improving ratings of caregiver experiences with health care and providers. Additional research with CMC is needed to determine which children benefit most from high-intensity care coordination. Copyright © 2015 National Association of Pediatric Nurse Practitioners. Published by Elsevier Inc. All rights reserved.
Scanning dimensional measurement using laser-trapped microsphere with optical standing-wave scale
NASA Astrophysics Data System (ADS)
Michihata, Masaki; Ueda, Shin-ichi; Takahashi, Satoru; Takamasu, Kiyoshi; Takaya, Yasuhiro
2017-06-01
We propose a laser trapping-based scanning dimensional measurement method for free-form surfaces. We previously developed a laser trapping-based microprobe for three-dimensional coordinate metrology. This probe performs two types of measurements: a tactile coordinate and a scanning measurement in the same coordinate system. The proposed scanning measurement exploits optical interference. A standing-wave field is generated between the laser-trapped microsphere and the measured surface because of the interference from the retroreflected light. The standing-wave field produces an effective length scale, and the trapped microsphere acts as a sensor to read this scale. A horizontal scan of the trapped microsphere produces a phase shift of the standing wave according to the surface topography. This shift can be measured from the change in the microsphere position. The dynamics of the trapped microsphere within the standing-wave field was estimated using a harmonic model, from which the measured surface can be reconstructed. A spherical lens was measured experimentally, yielding a radius of curvature of 2.59 mm, in agreement with the nominal specification (2.60 mm). The difference between the measured points and a spherical fitted curve was 96 nm, which demonstrates the scanning function of the laser trapping-based microprobe for free-form surfaces.
Automatic ball bar for a coordinate measuring machine
Jostlein, H.
1997-07-15
An automatic ball bar for a coordinate measuring machine determines the accuracy of a coordinate measuring machine having at least one servo drive. The apparatus comprises a first and second gauge ball connected by a telescoping rigid member. The rigid member includes a switch such that inward radial movement of the second gauge ball relative to the first gauge ball causes activation of the switch. The first gauge ball is secured in a first magnetic socket assembly in order to maintain the first gauge ball at a fixed location with respect to the coordinate measuring machine. A second magnetic socket assembly secures the second gauge ball to the arm or probe holder of the coordinate measuring machine. The second gauge ball is then directed by the coordinate measuring machine to move radially inward from a point just beyond the length of the ball bar until the switch is activated. Upon switch activation, the position of the coordinate measuring machine is determined and compared to known ball bar length such that the accuracy of the coordinate measuring machine can be determined. 5 figs.
Automatic ball bar for a coordinate measuring machine
Jostlein, Hans
1997-01-01
An automatic ball bar for a coordinate measuring machine determines the accuracy of a coordinate measuring machine having at least one servo drive. The apparatus comprises a first and second gauge ball connected by a telescoping rigid member. The rigid member includes a switch such that inward radial movement of the second gauge ball relative to the first gauge ball causes activation of the switch. The first gauge ball is secured in a first magnetic socket assembly in order to maintain the first gauge ball at a fixed location with respect to the coordinate measuring machine. A second magnetic socket assembly secures the second gauge ball to the arm or probe holder of the coordinate measuring machine. The second gauge ball is then directed by the coordinate measuring machine to move radially inward from a point just beyond the length of the ball bar until the switch is activated. Upon switch activation, the position of the coordinate measuring machine is determined and compared to known ball bar length such that the accuracy of the coordinate measuring machine can be determined.
NASA Astrophysics Data System (ADS)
Sorteberg, Hilleborg K.
2010-05-01
In the hydropower industry, it is important to have precise information about snow deposits at all times, to allow for effective planning and optimal use of the water. In Norway, it is common to measure snow density using a manual method, i.e. the depth and weight of the snow is measured. In recent years, radar measurements have been taken from snowmobiles; however, few energy supply companies use this method operatively - it has mostly been used in connection with research projects. Agder Energi is the first Norwegian power producer in using radar tecnology from helicopter in monitoring mountain snow levels. Measurement accuracy is crucial when obtaining input data for snow reservoir estimates. Radar screening by helicopter makes remote areas more easily accessible and provides larger quantities of data than traditional ground level measurement methods. In order to draw up a snow survey system, it is assumed as a basis that the snow distribution is influenced by vegetation, climate and topography. In order to take these factors into consideration, a snow survey system for fields in high mountain areas has been designed in which the data collection is carried out by following the lines of a grid system. The lines of this grid system is placed in order to effectively capture the distribution of elevation, x-coordinates, y-coordinates, aspect, slope and curvature in the field. Variation in climatic conditions are also captured better when using a grid, and dominant weather patterns will largely be captured in this measurement system.
The CEOS Atmospheric Composition Constellation: Enhancing the Value of Space-Based Observations
NASA Technical Reports Server (NTRS)
Eckman, Richard; Zehner, Claus; Al-Saadi, Jay
2015-01-01
The Committee on Earth Observation Satellites (CEOS) coordinates civil space-borne observations of the Earth. Participating agencies strive to enhance international coordination and data exchange and to optimize societal benefit. In recent years, CEOS has collaborated closely with the Group on Earth Observations (GEO) in implementing the Global Earth Observing System of Systems (GEOSS) space-based objectives. The goal of the CEOS Atmospheric Composition Constellation (ACC) is to collect and deliver data to improve monitoring, assessment and predictive capabilities for changes in the ozone layer, air quality and climate forcing associated with changes in the environment through coordination of existing and future international space assets. A project to coordinate and enhance the science value of a future constellation of geostationary sensors measuring parameters relevant to air quality supports the forthcoming European Sentinel-4, Korean GEMS, and US TEMPO missions. Recommendations have been developed for harmonization to mutually improve data quality and facilitate widespread use of the data products.
ERIC Educational Resources Information Center
Kirby, Edwena
2012-01-01
This book unveils "essential measures" that create a revitalized educational system of which educators and parents can use to promote student success. When these measures are applied properly, the benefits include, eradicating student fear, elevating student motivation, improving school attendance, and reducing student dropout rates. These…
Bonneville, Power Administration Timing System
NASA Technical Reports Server (NTRS)
Martin, Kenneth E.
1996-01-01
Time is an integral part of the Bonneville Power Administration's (BPA) operational systems. Generation and power transfers are planned in advance. Utilities coordinate with each other by making these adjustments on a timed schedule. Price varies with demand, so billing is based on time. Outages for maintenance are scheduled to assure they do not interrupt reliable power delivery. Disturbance records are aligned with recorded timetags for analysis and comparison with related information. Advanced applications like traveling wave fault location and real-time phase measurement require continuous timing with high precision. Most of BPA is served by a Central Time System (CTS) at the Dittmer Control Center near Portland, OR. This system keeps time locally and supplies time to both the control center systems and field locations via a microwave signal. It is kept synchronized to national standard time and coordinated with interconnected utilities. It is the official BPA time. Powwer system control and operation is described, followed by a description of BPA timing systems including CTS, the Fault Location Acquisition Reporter, time dissemination, and phasor measurements. References are provided for further reading.
Measurement of reach envelopes with a four-camera Selective Spot Recognition (SELSPOT) system
NASA Technical Reports Server (NTRS)
Stramler, J. H., Jr.; Woolford, B. J.
1983-01-01
The basic Selective Spot Recognition (SELSPOT) system is essentially a system which uses infrared LEDs and a 'camera' with an infrared-sensitive photodetector, a focusing lens, and some A/D electronics to produce a digital output representing an X and Y coordinate for each LED for each camera. When the data are synthesized across all cameras with appropriate calibrations, an XYZ set of coordinates is obtained for each LED at a given point in time. Attention is given to the operating modes, a system checkout, and reach envelopes and software. The Video Recording Adapter (VRA) represents the main addition to the basic SELSPOT system. The VRA contains a microprocessor and other electronics which permit user selection of several options and some interaction with the system.
HIFiRE-5 Flight Test Preliminary Results (Postprint)
2013-11-01
DMARS-R) IMU and Ashtech DG14 Global Positioning System receiver. Results show that a tripped transition occurred on the test article leading edge...Reference System (DMARS-R) IMU and Ashtech DG14 Global Positioning System receiver. Results show that a tripped transition occurred on the test...pitch angle relative to earth as measured by IMU , or flight-path elevation angle as measured by GPS or IMU , degrees = body-fixed angular coordinate
22 CFR 140.6 - Foreign government entities.
Code of Federal Regulations, 2010 CFR
2010-04-01
... measures taken. (6) A decision to withhold assistance or to take other measures based on information or... Coordinator shall be responsible for establishing a system for reviewing available information regarding... proposed recipient is located or, as appropriate, where assistance is to be provided, the information...
Draicchio, F; Silvetti, A; Ranavolo, A; Iavicoli, S
2008-01-01
We analyzed the coordination patterns between elbow, shoulder and trunk in a motor task consisting of reaching out, picking up a cylinder, and transporting it back by using the Dynamical Systems Theory and calculating the continuous relative phase (CRP), a continuous measure of the coupling between two interacting joints. We used an optoelectronic motion analysis system consisting of eight infra-red ray cameras to detect the movements of nine skin-mounted markers. We calculated the root square of the adjusted coefficient of determination, the coefficient of multiple correlation (CMC), in order to investigate the repeatability of the joints coordination. The data confirm that the CNS establishes both synergic (i.e. coupling between shoulder and trunk on the frontal plane) and hierarchical (i.e. coupling between elbow-shoulder-trunk on the horizontal plane) relationships among the available degrees of freedom to overcome the complexity due to motor redundancy. The present study describes a method to investigate the organization of the kinematic degrees of freedom during upper limb multi-joint motor tasks that can be useful to assess upper limb repetitive movements.
Hysong, Sylvia J; Thomas, Candice L; Spitzmüller, Christiane; Amspoker, Amber B; Woodard, LeChauncy; Modi, Varsha; Naik, Aanand D
2016-01-15
Team coordination within clinical care settings is a critical component of effective patient care. Less is known about the extent, effectiveness, and impact of coordination activities among professionals within VA Patient-Aligned Care Teams (PACTs). This study will address these gaps by describing the specific, fundamental tasks and practices involved in PACT coordination, their impact on performance measures, and the role of coordination task complexity. First, we will use a web-based survey of coordination practices among 1600 PACTs in the national VHA. Survey findings will characterize PACT coordination practices and assess their association with clinical performance measures. Functional job analysis, using 6-8 subject matter experts who are 3rd and 4th year residents in VA Primary Care rotations, will be utilized to identify the tasks involved in completing clinical performance measures to standard. From this, expert ratings of coordination complexity will be used to determine the level of coordinative complexity required for each of the clinical performance measures drawn from the VA External Peer Review Program (EPRP). For objective 3, data collected from the first two methods will evaluate the effect of clinical complexity on the relationships between measures of PACT coordination and their ratings on the clinical performance measures. Results from this study will support successful implementation of coordinated team-based work in clinical settings by providing knowledge regarding which aspects of care require the most complex levels of coordination and how specific coordination practices impact clinical performance.
Relativistic time transfer in the vicinity of the Earth and in the solar system
NASA Astrophysics Data System (ADS)
Nelson, Robert A.
2011-08-01
The algorithms for relativistic time transfer in the vicinity of the Earth and in the solar system are derived. The concepts of proper time and coordinate time are distinguished. The coordinate time elapsed during the transport of a clock and the propagation of an electromagnetic signal is analysed in three coordinate systems: an Earth-Centred Inertial (ECI) coordinate system, an Earth-Centred Earth-Fixed (ECEF) coordinate system and a barycentric coordinate system. The timescales of Geocentric Coordinate Time (TCG), Terrestrial Time (TT) and Barycentric Coordinate Time (TCB) are defined and their relationships are discussed. Some numerical examples are provided to illustrate the magnitudes of the effects.
The effect of implementing a care coordination program on team dynamics and the patient experience.
Di Capua, Paul; Clarke, Robin; Tseng, Chi-Hong; Wilhalme, Holly; Sednew, Renee; McDonald, Kathryn M; Skootsky, Samuel A; Wenger, Neil
2017-08-01
Care coordination programs are frequently implemented in the redesign of primary care systems, focused on improving patient outcomes and reducing utilization. However, redesign can be disruptive, affect patient experiences, and undermine elements in the patient-centered medical home, such as team-based care. Case-controlled study with difference-in-differences (DID) and cross-sectional analyses. The phased implementation of a care coordination program permitted evaluation of a natural experiment to compare measures of patient experience and teamwork in practices with and without care coordinators. Patient experience scores were compared before and after the introduction of care coordinators, using DID analyses. Cross-sectional data were used to compare teamwork, based on the relational coordination survey, and physician-perceived barriers to coordinated care between clinics with and without care coordinators. We evaluated survey responses from 459 staff and physicians and 13,441 patients in 26 primary care practices. Practices with care coordinators did not have significantly different relational coordination scores compared with practices without care coordinators, and physicians in these practices did not report reduced barriers to coordinated care. After implementation of the program, patients in practices with care coordinators reported a more positive experience with staff over time (DID, 2.6 percentage points; P = .0009). A flexible program that incorporates care coordinators into the existing care team was minimally disruptive to existing team dynamics, and the embedded care coordinators were associated with a small increase in patient ratings that reflected a more positive experience with staff.
Evaluation of arm-leg coordination in flat breaststroke.
Chollet, D; Seifert, L; Leblanc, H; Boulesteix, L; Carter, M
2004-10-01
This study proposes a new method to evaluate arm-leg coordination in flat breaststroke. Five arm and leg stroke phases were defined with a velocity-video system. Five time gaps quantified the time between arm and leg actions during three paces of a race (200 m, 100 m and 50 m) in 16 top level swimmers. Based on these time gaps, effective glide, effective propulsion, effective leg insweep and effective recovery were used to identify the different stroke phases of the body. A faster pace corresponded to increased stroke rate, decreased stroke length, increased propulsive phases, shorter glide phases, and a shorter T1 time gap, which measured the effective body glide. The top level swimmers showed short time gaps (T2, T3, T4, measuring the timing of arm-leg recoveries), which reflected the continuity in arm and leg actions. The measurement of these time gaps thus provides a pertinent evaluation of swimmers' skill in adapting their arm-leg coordination to biomechanical constraints.
NASA Technical Reports Server (NTRS)
Thompson, J. F.; Warsi, Z. U. A.; Mastin, C. W.
1982-01-01
A comprehensive review of methods of numerically generating curvilinear coordinate systems with coordinate lines coincident with all boundary segments is given. Some general mathematical framework and error analysis common to such coordinate systems is also included. The general categories of generating systems are those based on conformal mapping, orthogonal systems, nearly orthogonal systems, systems produced as the solution of elliptic and hyperbolic partial differential equations, and systems generated algebraically by interpolation among the boundaries. Also covered are the control of coordinate line spacing by functions embedded in the partial differential operators of the generating system and by subsequent stretching transformation. Dynamically adaptive coordinate systems, coupled with the physical solution, and time-dependent systems that follow moving boundaries are treated. References reporting experience using such coordinate systems are reviewed as well as those covering the system development.
Measuring the Attainment of Primary Care.
ERIC Educational Resources Information Center
Starfield, Barbara
1979-01-01
The definition of primary care is developed and a way is suggested to measure whether it is being achieved. Evaluative questions are identified that can determine whether a system of care is oriented toward primary care. They include assessing first-contact care, coordination of care, comprehensiveness, and longitudinality. (LBH)
In vivo wear. Part I: The Michigan computer-graphic measuring system.
McDowell, G C; Bloem, T J; Lang, B R; Asgar, K
1988-07-01
Three-dimensional coordinate measuring machines for examining the quality of industrial castings were reviewed. The concept was modified and successfully converted to examine the minute geometric configurations of the surfaces of dental materials. The wear of composites has undoubtedly precipitated this perceptive, thorough study.
Chen, Zhe; Zhang, Fumin; Qu, Xinghua; Liang, Baoqiu
2015-01-01
In this paper, we propose a new approach for the measurement and reconstruction of large workpieces with freeform surfaces. The system consists of a handheld laser scanning sensor and a position sensor. The laser scanning sensor is used to acquire the surface and geometry information, and the position sensor is utilized to unify the scanning sensors into a global coordinate system. The measurement process includes data collection, multi-sensor data fusion and surface reconstruction. With the multi-sensor data fusion, errors accumulated during the image alignment and registration process are minimized, and the measuring precision is significantly improved. After the dense accurate acquisition of the three-dimensional (3-D) coordinates, the surface is reconstructed using a commercial software piece, based on the Non-Uniform Rational B-Splines (NURBS) surface. The system has been evaluated, both qualitatively and quantitatively, using reference measurements provided by a commercial laser scanning sensor. The method has been applied for the reconstruction of a large gear rim and the accuracy is up to 0.0963 mm. The results prove that this new combined method is promising for measuring and reconstructing the large-scale objects with complex surface geometry. Compared with reported methods of large-scale shape measurement, it owns high freedom in motion, high precision and high measurement speed in a wide measurement range. PMID:26091396
Gamm, Larry; Bolin, Jane Nelson; Kash, Bita A
2005-01-01
Four large rural multispecialty group practice systems employ a mix of organizational technologies to provide chronic disease management with measurable impacts on their patient populations and costs. Four technologies-administrative, clinical, information, and social-are proposed as key dimensions for examining disease management programs. The benefits of disease management are recognized by these systems despite marked variability in the organization of the programs. Committees spanning health plans and clinics in the 4 systems and electronic medical records and/or other disease management information systems are important coordinating mechanisms. Increased reliance on nurses for patient education and care coordination in all 4 systems reflects significant extension of clinical and social technologies in the management of patient care. The promise of disease management as offered by these systems and other auspices are considered.
Patient population management: taking the leap from variance analysis to outcomes measurement.
Allen, K M
1998-01-01
Case managers today at BCHS have a somewhat different role than at the onset of the Collaborative Practice Model. They are seen throughout the organization as: Leaders/participants on cross-functional teams. Systems change agents. Integrating/merging with quality services and utilization management. Outcomes managers. One of the major cross-functional teams is in the process of designing a Care Coordinator role. These individuals will, as one of their functions, assume responsibility for daily patient care management activities. A variance tracking program has come into the Utilization Management (UM) department as part of a software package purchased to automate UM work activities. This variance program could potentially be used by the new care coordinators as the role develops. The case managers are beginning to use a Decision Support software, (Transition Systems Inc.) in the collection of data that is based on a cost accounting system and linked to clinical events. Other clinical outcomes data bases are now being used by the case manager to help with the collection and measurement of outcomes information. Hoshin planning will continue to be a framework for defining and setting the targets for clinical and financial improvements throughout the organization. Case managers will continue to be involved in many of these system-wide initiatives. In the words of Galileo, 1579, "You need to count what's countable, measure what's measurable, and what's not measurable, make measurable."
Integrating Multiple Space Ground Sensors to Track Volcanic Activity
NASA Technical Reports Server (NTRS)
Chien, Steve; Davies, Ashley; Doubleday, Joshua; Tran, Daniel; Jones, Samuel; Kjartansson, Einar; Thorsteinsson, Hrobjartur; Vogfjord, Kristin; Guomundsson, Magnus; Thordarson, Thor;
2011-01-01
Volcanic activity can occur with little or no warning. Increasing numbers of space borne assets can enable coordinated measurements of volcanic events to enhance both scientific study and hazard response. We describe the use of space and ground measurements to target further measurements as part of a worldwide volcano monitoring system. We utilize a number of alert systems including the MODVOLC, GOESVOLC, US Air Force Weather Advisory, and Volcanic Ash Advisory Center (VAAC) alert systems. Additionally we use in-situ data from ground instrumentation at a number of volcanic sites, including Iceland.
Analysis of measurement system as the mechatronics system
NASA Astrophysics Data System (ADS)
Giniotis, V.; Grattan, K. T. V.; Rybokas, M.; Bručas, D.
2010-07-01
The paper deals with the mechatronic arrangement for angle measuring system application. The objects to be measured are the circular raster scales, rotary encoders and coded scales. The task of the measuring system is to determine the bias of angle measuring standard as the circular scale and to use the results for the error correction and accuracy improvement of metal cutting machines, coordinate measuring machines, robots, etc. The technical solutions are given with the application of active materials for smart piezoactuators implemented into the several positions of angular measuring equipment. Mechatronic measuring system is analysed as complex integrated system and some of its elements can be used as separate units. All these functional elements are described and commented in the paper with the diagrams and graphs of errors and examples of microdisplacement devices using the mechatronic elements.
Coordination control of flexible manufacturing systems
NASA Astrophysics Data System (ADS)
Menon, Satheesh R.
One of the first attempts was made to develop a model driven system for coordination control of Flexible Manufacturing Systems (FMS). The structure and activities of the FMS are modeled using a colored Petri Net based system. This approach has the advantage of being able to model the concurrency inherent in the system. It provides a method for encoding the system state, state transitions and the feasible transitions at any given state. Further structural analysis (for detecting conflicting actions, deadlocks which might occur during operation, etc.) can be performed. The problem is also addressed of implementing and testing the behavior of existing dynamic scheduling approaches in simulations of realistic situations. A simulation architecture was proposed and performance evaluation was carried out for establishing the correctness of the model, stability of the system from a structural (deadlocks) and temporal (boundedness of backlogs) points of view, and for collection of statistics for performance measures such as machine and robot utilizations, average wait times and idle times of resources. A real-time implementation architecture for the coordination controller was also developed and implemented in a software simulated environment. Given the current technology of FMS control, the model-driven colored Petri net-based approach promises to develop a very flexible control environment.
A New Global Regression Analysis Method for the Prediction of Wind Tunnel Model Weight Corrections
NASA Technical Reports Server (NTRS)
Ulbrich, Norbert Manfred; Bridge, Thomas M.; Amaya, Max A.
2014-01-01
A new global regression analysis method is discussed that predicts wind tunnel model weight corrections for strain-gage balance loads during a wind tunnel test. The method determines corrections by combining "wind-on" model attitude measurements with least squares estimates of the model weight and center of gravity coordinates that are obtained from "wind-off" data points. The method treats the least squares fit of the model weight separate from the fit of the center of gravity coordinates. Therefore, it performs two fits of "wind- off" data points and uses the least squares estimator of the model weight as an input for the fit of the center of gravity coordinates. Explicit equations for the least squares estimators of the weight and center of gravity coordinates are derived that simplify the implementation of the method in the data system software of a wind tunnel. In addition, recommendations for sets of "wind-off" data points are made that take typical model support system constraints into account. Explicit equations of the confidence intervals on the model weight and center of gravity coordinates and two different error analyses of the model weight prediction are also discussed in the appendices of the paper.
Gorin, Sherri Sheinfeld; Haggstrom, David; Han, Paul K J; Fairfield, Kathleen M; Krebs, Paul; Clauser, Steven B
2017-08-01
According to a landmark study by the Institute of Medicine, patients with cancer often receive poorly coordinated care in multiple settings from many providers. Lack of coordination is associated with poor symptom control, medical errors, and higher costs. The aims of this systematic review and meta-analysis were to (1) synthesize the findings of studies addressing cancer care coordination, (2) describe study outcomes across the cancer continuum, and (3) obtain a quantitative estimate of the effect of interventions in cancer care coordination on service system processes and patient health outcomes. Of 1241 abstracts identified through MEDLINE, EMBASE, CINAHL, and the Cochrane Library, 52 studies met the inclusion criteria. Each study had US or Canadian participants, comparison or control groups, measures, times, samples, and/or interventions. Two researchers independently applied a standardized search strategy, coding scheme, and online coding program to each study. Eleven studies met the additional criteria for the meta-analysis; a random effects estimation model was used for data analysis. Cancer care coordination approaches led to improvements in 81 % of outcomes, including screening, measures of patient experience with care, and quality of end-of-life care. Across the continuum of cancer care, patient navigation was the most frequent care coordination intervention, followed by home telehealth; nurse case management was third in frequency. The meta-analysis of a subset of the reviewed studies showed that the odds of appropriate health care utilization in cancer care coordination interventions were almost twice (OR = 1.9, 95 % CI = 1.5-3.5) that of comparison interventions. This review offers promising findings on the impact of cancer care coordination on increasing value and reducing healthcare costs in the USA.
Normalized Index of Synergy for Evaluating the Coordination of Motor Commands
Togo, Shunta; Imamizu, Hiroshi
2015-01-01
Humans perform various motor tasks by coordinating the redundant motor elements in their bodies. The coordination of motor outputs is produced by motor commands, as well properties of the musculoskeletal system. The aim of this study was to dissociate the coordination of motor commands from motor outputs. First, we conducted simulation experiments where the total elbow torque was generated by a model of a simple human right and left elbow with redundant muscles. The results demonstrated that muscle tension with signal-dependent noise formed a coordinated structure of trial-to-trial variability of muscle tension. Therefore, the removal of signal-dependent noise effects was required to evaluate the coordination of motor commands. We proposed a method to evaluate the coordination of motor commands, which removed signal-dependent noise from the measured variability of muscle tension. We used uncontrolled manifold analysis to calculate a normalized index of synergy. Simulation experiments confirmed that the proposed method could appropriately represent the coordinated structure of the variability of motor commands. We also conducted experiments in which subjects performed the same task as in the simulation experiments. The normalized index of synergy revealed that the subjects coordinated their motor commands to achieve the task. Finally, the normalized index of synergy was applied to a motor learning task to determine the utility of the proposed method. We hypothesized that a large part of the change in the coordination of motor outputs through learning was because of changes in motor commands. In a motor learning task, subjects tracked a target trajectory of the total torque. The change in the coordination of muscle tension through learning was dominated by that of motor commands, which supported the hypothesis. We conclude that the normalized index of synergy can be used to evaluate the coordination of motor commands independently from the properties of the musculoskeletal system. PMID:26474043
Enhancing communication by using the Coordinated Care Classification System.
O'Neal, P V; Kozeny, D K; Garland, P P; Gaunt, S M; Gordon, S C
1998-07-01
Because of the changes in our healthcare system, some clinical nurse specialists (CNSs) are having to expand their traditional roles of clinician, educator, consultant, leader, and researcher to include case management activities. The CNSs at Promina Gwinnett Health System in Lawrenceville, Georgia, have combined CNS and case manager activities and have adopted the title "CNS/Outcomes Coordinator." The CNS/Outcomes Coordinator is responsible for coordinating patient care, promoting team collaboration, and facilitating communication. To inform the healthcare team of the CNS/Outcomes Coordinator's patient responsibilities, the CNS/Outcomes Coordinators developed a Coordinated Care Classification System. This article describes how coordinating patient care, promoting team collaboration, and facilitating communication can be enhanced by the use of a classification system.
... are recorded as warm and cool water or air are gently introduced into each ear canal. Since the eyes and ears work in coordination through the nervous system, measurement of eye movements can be used to test ...
Deviation rectification for dynamic measurement of rail wear based on coordinate sets projection
NASA Astrophysics Data System (ADS)
Wang, Chao; Ma, Ziji; Li, Yanfu; Zeng, Jiuzhen; Jin, Tan; Liu, Hongli
2017-10-01
Dynamic measurement of rail wear using a laser imaging system suffers from random vibrations in the laser-based imaging sensor which cause distorted rail profiles. In this paper, a simple and effective method for rectifying profile deviation is presented to address this issue. There are two main steps: profile recognition and distortion calibration. According to the constant camera and projector parameters, efficient recognition of measured profiles is achieved by analyzing the geometric difference between normal profiles and distorted ones. For a distorted profile, by constructing coordinate sets projecting from it to the standard one on triple projecting primitives, including the rail head inner line, rail waist curve and rail jaw, iterative extrinsic camera parameter self-compensation is implemented. The distortion is calibrated by projecting the distorted profile onto the x-y plane of a measuring coordinate frame, which is parallel to the rail cross section, to eliminate the influence of random vibrations in the laser-based imaging sensor. As well as evaluating the implementation with comprehensive experiments, we also compare our method with other published works. The results exhibit the effectiveness and superiority of our method for the dynamic measurement of rail wear.
Study on verifying the angle measurement performance of the rotary-laser system
NASA Astrophysics Data System (ADS)
Zhao, Jin; Ren, Yongjie; Lin, Jiarui; Yin, Shibin; Zhu, Jigui
2018-04-01
An angle verification method to verify the angle measurement performance of the rotary-laser system was developed. Angle measurement performance has a great impact on measuring accuracy. Although there is some previous research on the verification of angle measuring uncertainty for the rotary-laser system, there are still some limitations. High-precision reference angles are used in the study of the method, and an integrated verification platform is set up to evaluate the performance of the system. This paper also probes the error that has biggest influence on the verification system. Some errors of the verification system are avoided via the experimental method, and some are compensated through the computational formula and curve fitting. Experimental results show that the angle measurement performance meets the requirement for coordinate measurement. The verification platform can evaluate the uncertainty of angle measurement for the rotary-laser system efficiently.
Automated Wing Twist And Bending Measurements Under Aerodynamic Load
NASA Technical Reports Server (NTRS)
Burner, A. W.; Martinson, S. D.
1996-01-01
An automated system to measure the change in wing twist and bending under aerodynamic load in a wind tunnel is described. The basic instrumentation consists of a single CCD video camera and a frame grabber interfaced to a computer. The technique is based upon a single view photogrammetric determination of two dimensional coordinates of wing targets with a fixed (and known) third dimensional coordinate, namely the spanwise location. The measurement technique has been used successfully at the National Transonic Facility, the Transonic Dynamics Tunnel, and the Unitary Plan Wind Tunnel at NASA Langley Research Center. The advantages and limitations (including targeting) of the technique are discussed. A major consideration in the development was that use of the technique must not appreciably reduce wind tunnel productivity.
After Action Report: Idaho National Laboratory Annual Exercise June 10, 2015
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnes, Vernon Scott
On June 10, 2015, Idaho National Laboratory (INL), in coordination with the State of Idaho, local jurisdictions, Department of Energy Idaho Operations Office (DOE-ID), and DOE Headquarters (DOE HQ), conducted the annual emergency exercise to demonstrate the ability to implement the requirements of DOE O 151.1C, “Comprehensive Emergency Management System.” The INL contractor, Battelle Energy Alliance, LLC (BEA), in coordination with other INL contractors, conducted operations and demonstrated appropriate response measures to mitigate an event and protect the health and safety of personnel, the environment, and property. Offsite response organizations participated to demonstrate appropriate response measures.
Blakey, John D; Guy, Debbie; Simpson, Carl; Fearn, Andrew; Cannaby, Sharon; Wilson, Petra
2012-01-01
Objectives The authors investigated if a wireless system of call handling and task management for out of hours care could replace a standard pager-based system and improve markers of efficiency, patient safety and staff satisfaction. Design Prospective assessment using both quantitative and qualitative methods, including interviews with staff, a standard satisfaction questionnaire, independent observation, data extraction from work logs and incident reporting systems and analysis of hospital committee reports. Setting A large teaching hospital in the UK. Participants Hospital at night co-ordinators, clinical support workers and junior doctors handling approximately 10 000 tasks requested out of hours per month. Outcome measures Length of hospital stay, incidents reported, co-ordinator call logging activity, user satisfaction questionnaire, staff interviews. Results Users were more satisfied with the new system (satisfaction score 62/90 vs 82/90, p=0.0080). With the new system over 70 h/week of co-ordinator time was released, and there were fewer untoward incidents related to handover and medical response (OR=0.30, p=0.02). Broad clinical measures (cardiac arrest calls for peri-arrest situations and length of hospital stay) improved significantly in the areas covered by the new system. Conclusions The introduction of call handling software and mobile technology over a medical-grade wireless network improved staff satisfaction with the Hospital at Night system. Improvements in efficiency and information flow have been accompanied by a reduction in untoward incidents, length of stay and peri-arrest calls. PMID:22466035
Global Geodesy Using GPS Without Fiducial Sites
NASA Technical Reports Server (NTRS)
Heflin, Michael B.; Blewitt, Geoffrey
1994-01-01
Global Positioning System, GPS, used to make global geodetic measurements without use of fiducial site coordinates. Baseline lengths and geocentric radii for each site determined without having to fix any site coordinates. Given n globally distributed sites, n baseline lengths and n geocentric radii form polyhedron with each site at vertex and with geocenter at intersection of all radii. Geodetic information derived from structure of polyhedron and its change with time. Approach applied to any global geodetic technique.
Application of Composite Small Calibration Objects in Traffic Accident Scene Photogrammetry
Chen, Qiang; Xu, Hongguo; Tan, Lidong
2015-01-01
In order to address the difficulty of arranging large calibration objects and the low measurement accuracy of small calibration objects in traffic accident scene photogrammetry, a photogrammetric method based on a composite of small calibration objects is proposed. Several small calibration objects are placed around the traffic accident scene, and the coordinate system of the composite calibration object is given based on one of them. By maintaining the relative position and coplanar relationship of the small calibration objects, the local coordinate system of each small calibration object is transformed into the coordinate system of the composite calibration object. The two-dimensional direct linear transformation method is improved based on minimizing the reprojection error of the calibration points of all objects. A rectified image is obtained using the nonlinear optimization method. The increased accuracy of traffic accident scene photogrammetry using a composite small calibration object is demonstrated through the analysis of field experiments and case studies. PMID:26011052
Optoelectronic scanning system upgrade by energy center localization methods
NASA Astrophysics Data System (ADS)
Flores-Fuentes, W.; Sergiyenko, O.; Rodriguez-Quiñonez, J. C.; Rivas-López, M.; Hernández-Balbuena, D.; Básaca-Preciado, L. C.; Lindner, L.; González-Navarro, F. F.
2016-11-01
A problem of upgrading an optoelectronic scanning system with digital post-processing of the signal based on adequate methods of energy center localization is considered. An improved dynamic triangulation analysis technique is proposed by an example of industrial infrastructure damage detection. A modification of our previously published method aimed at searching for the energy center of an optoelectronic signal is described. Application of the artificial intelligence algorithm of compensation for the error of determining the angular coordinate in calculating the spatial coordinate through dynamic triangulation is demonstrated. Five energy center localization methods are developed and tested to select the best method. After implementation of these methods, digital compensation for the measurement error, and statistical data analysis, a non-parametric behavior of the data is identified. The Wilcoxon signed rank test is applied to improve the result further. For optical scanning systems, it is necessary to detect a light emitter mounted on the infrastructure being investigated to calculate its spatial coordinate by the energy center localization method.
78 FR 38981 - Statement of Organization Functions, and Delegations of Authority
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-28
... integration of the budget and planning processes. Manages evaluation and measurement activities for the Agency... financial accounting and reporting systems and coordinates responses on budget and accounting matters with...
An analysis of a discrete complex skill using Bernstein's stages of learning.
Smith, D R; McCabe, D R; Wilkerson, J D
2001-08-01
The purpose of this study was to provide quantitative data about changes in coordination after practicing a racquetball forehand drive serve. Novice women (N = 10) were videotaped before and after 10 min. of practicing a racquetball forehand drive serve on Day 1, and after 10-min. practice sessions on consecutive Days 2 through 5. The PEAK5 Motion Measurement System was used to evaluate the following dependent variables: (a) range of motion of the wrist, elbow, upper torso, and pelvis from backswing to ball contact: (b) racket head velocity at ball contact; and (c) coordination. Coordination was evaluated based on analysis of the angular velocity graphs of each performance to assess sequencing and timing of the segmental contributions. Shared positive contribution was assessed between adjacent 2-segment combinations: pelvis-torso and elbow-wrist. A repeated-measures analysis of variance indicated racket velocity, pelvic rotation, and upper torso rotation significantly increased over the 5 days of practice. Although participants increased their pelvic and torso ranges of motion and racket velocity, improvement in coordination was not documented.
Post-Flight Estimation of Motion of Space Structures: Part 2
NASA Technical Reports Server (NTRS)
Brugarolas, Paul; Breckenridge, William
2008-01-01
A computer program related to the one described in the immediately preceding article estimates the relative position of two space structures that are hinged to each other. The input to the program consists of time-series data on distances, measured by two range finders at different positions on one structure, to a corner-cube retroreflector on the other structure. Given a Cartesian (x,y,z) coordinate system and the known x coordinate of the retroreflector relative to the y,z plane that contains the range finders, the program estimates the y and z coordinates of the retroreflector. The estimation process involves solving for the y,z coordinates of the intersection between (1) the y,z plane that contains the retroreflector and (2) spheres, centered on the range finders, having radii equal to the measured distances. In general, there are two such solutions and the program chooses the one consistent with the design of the structures. The program implements a Kalman filter. The output of the program is a time series of estimates of the relative position of the structures.
Trute, B; Hiebert-Murphy, D; Wright, A
2008-05-01
Potential service outcome measures were tested for their utility in the assessment of the quality of 'family centred' service coordination in the provincial network of children's disability services in Manitoba, Canada. This study is based on in-home survey data provided by 103 mothers at 6 and 18 months following assignment of a 'dedicated' service coordinator. Service outcome indicators included measures of parent self-esteem, parenting stress, family functioning and the need for family support resources. Hierarchical regression analyses showed no relationship between level of quality of family-centred service coordination and standardized psychosocial measures of parent and family functioning. However, family centredness of service coordination was found to predict significant reduction in level of family need for psychosocial support resources after 18 months of contact with a service coordinator. Outcome measures that are focused on specific and tangible results of service coordination appear to be of higher utility in service quality assessment than are more global, standardized measures of parent and family functioning.
Inertial Pointing and Positioning System
NASA Technical Reports Server (NTRS)
Yee, Robert (Inventor); Robbins, Fred (Inventor)
1998-01-01
An inertial pointing and control system and method for pointing to a designated target with known coordinates from a platform to provide accurate position, steering, and command information. The system continuously receives GPS signals and corrects Inertial Navigation System (INS) dead reckoning or drift errors. An INS is mounted directly on a pointing instrument rather than in a remote location on the platform for-monitoring the terrestrial position and instrument attitude. and for pointing the instrument at designated celestial targets or ground based landmarks. As a result. the pointing instrument and die INS move independently in inertial space from the platform since the INS is decoupled from the platform. Another important characteristic of the present system is that selected INS measurements are combined with predefined coordinate transformation equations and control logic algorithms under computer control in order to generate inertial pointing commands to the pointing instrument. More specifically. the computer calculates the desired instrument angles (Phi, Theta. Psi). which are then compared to the Euler angles measured by the instrument- mounted INS. and forms the pointing command error angles as a result of the compared difference.
Guiding Principles for Data Architecture to Support the Pathways Community HUB Model
Zeigler, Bernard P.; Redding, Sarah; Leath, Brenda A.; Carter, Ernest L.; Russell, Cynthia
2016-01-01
Introduction: The Pathways Community HUB Model provides a unique strategy to effectively supplement health care services with social services needed to overcome barriers for those most at risk of poor health outcomes. Pathways are standardized measurement tools used to define and track health and social issues from identification through to a measurable completion point. The HUB use Pathways to coordinate agencies and service providers in the community to eliminate the inefficiencies and duplication that exist among them. Pathways Community HUB Model and Formalization: Experience with the Model has brought out the need for better information technology solutions to support implementation of the Pathways themselves through decision-support tools for care coordinators and other users to track activities and outcomes, and to facilitate reporting. Here we provide a basis for discussing recommendations for such a data infrastructure by developing a conceptual model that formalizes the Pathway concept underlying current implementations. Requirements for Data Architecture to Support the Pathways Community HUB Model: The main contribution is a set of core recommendations as a framework for developing and implementing a data architecture to support implementation of the Pathways Community HUB Model. The objective is to present a tool for communities interested in adopting the Model to learn from and to adapt in their own development and implementation efforts. Problems with Quality of Data Extracted from the CHAP Database: Experience with the Community Health Access Project (CHAP) data base system (the core implementation of the Model) has identified several issues and remedies that have been developed to address these issues. Based on analysis of issues and remedies, we present several key features for a data architecture meeting the just mentioned recommendations. Implementation of Features: Presentation of features is followed by a practical guide to their implementation allowing an organization to consider either tailoring off-the-shelf generic systems to meet the requirements or offerings that are specialized for community-based care coordination. Discussion: Looking to future extensions, we discuss the utility and prospects for an ontology to include care coordination in the Unified Medical Language System (UMLS) of the National Library of Medicine and other existing medical and nursing taxonomies. Conclusions and Recommendations: Pathways structures are an important principle, not only for organizing the care coordination activities, but also for structuring the data stored in electronic form in the conduct of such care. We showed how the proposed architecture encourages design of effective decision support systems for coordinated care and suggested how interested organizations can set about acquiring such systems. Although the presentation focuses on the Pathways Community HUB Model, the principles for data architecture are stated in generic form and are applicable to any health information system for improving care coordination services and population health. PMID:26870743
15 CFR 1170.3 - General policy.
Code of Federal Regulations, 2012 CFR
2012-01-01
... extent economically feasible by the end of the fiscal year 1992, use the metric system of measurement in...) Federal agencies shall coordinate and plan for the use of the metric system in their procurements, grants... ADMINISTRATION, DEPARTMENT OF COMMERCE METRIC CONVERSION POLICY FOR FEDERAL AGENCIES § 1170.3 General policy. The...
15 CFR 1170.3 - General policy.
Code of Federal Regulations, 2013 CFR
2013-01-01
... extent economically feasible by the end of the fiscal year 1992, use the metric system of measurement in...) Federal agencies shall coordinate and plan for the use of the metric system in their procurements, grants... ADMINISTRATION, DEPARTMENT OF COMMERCE METRIC CONVERSION POLICY FOR FEDERAL AGENCIES § 1170.3 General policy. The...
15 CFR 1170.3 - General policy.
Code of Federal Regulations, 2011 CFR
2011-01-01
... extent economically feasible by the end of the fiscal year 1992, use the metric system of measurement in...) Federal agencies shall coordinate and plan for the use of the metric system in their procurements, grants... ADMINISTRATION, DEPARTMENT OF COMMERCE METRIC CONVERSION POLICY FOR FEDERAL AGENCIES § 1170.3 General policy. The...
ERIC Educational Resources Information Center
Walsh, Patrick L.
1982-01-01
The Educational Quality Assessment and Assurance System for continuing education in health sciences includes three components to measure inputs, processes, and outcomes. They are (1) Program Coordinator Competency List, (2) Quality Assessment and Assurance Program, and (3) evaluation of educational programs. (SK)
Jankowski, Piotr; Gąsior, Mariusz; Gierlotka, Marek; Cegłowska, Urszula; Słomka, Marta; Eysymontt, Zbigniew; Gałaszek, Michał; Buszman, Piotr; Kalarus, Zbigniew; Kaźmierczak, Jarosław; Legutko, Jacek; Sujkowska, Gabriela; Matusewicz, Wojciech; Opolski, Grzegorz; Hoffman, Piotr
2016-01-01
The in-hospital mortality following myocardial infarction has decreased substantially over the last two decades in Poland. However, according to the available evidence approximately every 10th patient discharged after myocardial infarction (MI) dies during next 12 months. We identified the most important barriers (e.g. insufficient risk factors control, insufficient and delayed cardiac rehabilitation, suboptimal pharmacotherapy, delayed complete myocardial revascularisation) and proposed a new nation-wide system of coordinated care after MI. The system should consist of four modules: complete revascularisation, education and rehabilitation programme, electrotherapy (including ICDs and BiVs when appropriate) and periodical cardiac consultations. At first stage the coordinated care programme should last 12 months. The proposal contains also the quality of care assessment based on clinical measures (e.g. risk factors control, rate of complete myocardial revascularisation, etc.) as well as on the rate of cardiovascular events. The wide implementation of the proposed system is expected to decrease one year mortality after MI and allow for better financial resources allocation in Poland.
Overreaching in coordination dynamics therapy in an athlete with a spinal cord injury.
Schalow, G; Vaher, I; Jaigma, P
2008-03-01
A motocross athlete suffered a clinically complete spinal cord injury (SCI) during competition. Although MRIs (magnetic resonance imaging) showed a complete spinal cord injury at the Thoracic 11/12 levels, surface EMG recordings indicated the survival of few tract fibres across the injury site. Six weeks after the accident the subject began intensive Coordination Dynamics Therapy (CDT) at an up-to-date therapy centre. The subject trained at his physical limits to induce structural and functional repair. Exercising at variable loads between 20 and 200N (on a special CDT and recording device) generated periods of overreaching and super-compensation. By plotting coordination dynamics values (kinesiology), including high-load exertion (200N) and hysteresis curves, periods of overreaching and super-compensation were made graphically visible. It was found that symmetrical improvements of central nervous system (CNS) functioning occurred during overreaching. Improvements in spinal cord functioning were achieved throughout one year of CDT in this chronically injured subject with an almost anatomically complete SCI. It is discussed that the measuring of CNS functions by means of recording coordination dynamics is a powerful and non-invasive tool ideal for exact quantitative and qualitative measurements of improvement (or change) in CNS functioning. Such diagnostics may be of particular importance in sport during training and before competition. Also, coordination dynamics might be used to measure the effects of prolonged exposure to reduced gravitational conditions on CNS functions, such as faced by astronauts.
Berens, Angelique M; Harbison, Richard Alex; Li, Yangming; Bly, Randall A; Aghdasi, Nava; Ferreira, Manuel; Hannaford, Blake; Moe, Kris S
2017-08-01
To develop a method to measure intraoperative surgical instrument motion. This model will be applicable to the study of surgical instrument kinematics including surgical training, skill verification, and the development of surgical warning systems that detect aberrant instrument motion that may result in patient injury. We developed an algorithm to automate derivation of surgical instrument kinematics in an endoscopic endonasal skull base surgery model. Surgical instrument motion was recorded during a cadaveric endoscopic transnasal approach to the pituitary using a navigation system modified to record intraoperative time-stamped Euclidian coordinates and Euler angles. Microdebrider tip coordinates and angles were referenced to the cadaver's preoperative computed tomography scan allowing us to assess surgical instrument kinematics over time. A representative cadaveric endoscopic endonasal approach to the pituitary was performed to demonstrate feasibility of our algorithm for deriving surgical instrument kinematics. Technical feasibility of automatically measuring intraoperative surgical instrument motion and deriving kinematics measurements was demonstrated using standard navigation equipment.
ERIC Educational Resources Information Center
Kuhn, Robert H.
1981-01-01
Internal control comprises the plan of organization and all the coordinate methods and measures adopted within a school system to safeguard its assets, check the reliability of its accounting data, promote operational efficiency, and encourage adherence to prescribed policies. (Author)
Bias Reduction and Filter Convergence for Long Range Stereo
NASA Technical Reports Server (NTRS)
Sibley, Gabe; Matthies, Larry; Sukhatme, Gaurav
2005-01-01
We are concerned here with improving long range stereo by filtering image sequences. Traditionally, measurement errors from stereo camera systems have been approximated as 3-D Gaussians, where the mean is derived by triangulation and the covariance by linearized error propagation. However, there are two problems that arise when filtering such 3-D measurements. First, stereo triangulation suffers from a range dependent statistical bias; when filtering this leads to over-estimating the true range. Second, filtering 3-D measurements derived via linearized error propagation leads to apparent filter divergence; the estimator is biased to under-estimate range. To address the first issue, we examine the statistical behavior of stereo triangulation and show how to remove the bias by series expansion. The solution to the second problem is to filter with image coordinates as measurements instead of triangulated 3-D coordinates.
NASA Astrophysics Data System (ADS)
Sycheva, Elena A.; Vasilev, Aleksandr S.; Lashmanov, Oleg U.; Korotaev, Valery V.
2017-06-01
The article is devoted to the optimization of optoelectronic systems of the spatial position of objects. Probabilistic characteristics of the detection of an active structured mark on a random noisy background are investigated. The developed computer model and the results of the study allow us to estimate the probabilistic characteristics of detection of a complex structured mark on a random gradient background, and estimate the error of spatial coordinates. The results of the study make it possible to improve the accuracy of measuring the coordinates of the object. Based on the research recommendations are given on the choice of parameters of the optimal mark structure for use in opticalelectronic systems for monitoring the spatial position of large-sized structures.
The effect of transponder motion on the accuracy of the Calypso Electromagnetic localization system.
Murphy, Martin J; Eidens, Richard; Vertatschitsch, Edward; Wright, J Nelson
2008-09-01
To determine position and velocity-dependent effects in the overall accuracy of the Calypso Electromagnetic localization system, under conditions that emulate transponder motion during normal free breathing. Three localization transponders were mounted on a remote-controlled turntable that could move the transponders along a circular trajectory at speeds up to 3 cm/s. A stationary calibration established the coordinates of multiple points on each transponder's circular path. Position measurements taken while the transponders were in motion at a constant speed were then compared with the stationary coordinates. No statistically significant changes in the transponder positions in (x,y,z) were detected when the transponders were in motion. The accuracy of the localization system is unaffected by transponder motion.
NASA Astrophysics Data System (ADS)
Cong, Wang; Xu, Lingdi; Li, Ang
2017-10-01
Large aspheric surface which have the deviation with spherical surface are being used widely in various of optical systems. Compared with spherical surface, Large aspheric surfaces have lots of advantages, such as improving image quality, correcting aberration, expanding field of view, increasing the effective distance and make the optical system compact, lightweight. Especially, with the rapid development of space optics, space sensor resolution is required higher and viewing angle is requred larger. Aspheric surface will become one of the essential components in the optical system. After finishing Aspheric coarse Grinding surface profile error is about Tens of microns[1].In order to achieve the final requirement of surface accuracy,the aspheric surface must be quickly modified, high precision testing is the basement of rapid convergence of the surface error . There many methods on aspheric surface detection[2], Geometric ray detection, hartmann detection, ronchi text, knifeedge method, direct profile test, interferometry, while all of them have their disadvantage[6]. In recent years the measure of the aspheric surface become one of the import factors which are restricting the aspheric surface processing development. A two meter caliber industrial CMM coordinate measuring machine is avaiable, but it has many drawbacks such as large detection error and low repeatability precision in the measurement of aspheric surface coarse grinding , which seriously affects the convergence efficiency during the aspherical mirror processing. To solve those problems, this paper presents an effective error control, calibration and removal method by calibration mirror position of the real-time monitoring and other effective means of error control, calibration and removal by probe correction and the measurement mode selection method to measure the point distribution program development. This method verified by real engineer examples, this method increases the original industrial-grade coordinate system nominal measurement accuracy PV value of 7 microns to 4microns, Which effectively improves the grinding efficiency of aspheric mirrors and verifies the correctness of the method. This paper also investigates the error detection and operation control method, the error calibration of the CMM and the random error calibration of the CMM .
Dückers, Michel L A; Thormar, Sigridur B; Juen, Barbara; Ajdukovic, Dean; Newlove-Eriksson, Lindy; Olff, Miranda
2018-01-01
Disasters can have an enormous impact on the health and well-being of those affected. Internationally, governments and service providers are often challenged to address complex psychosocial problems. Ideally, the potentially broad range of support activities include a coherent, high-quality mental health and psychosocial support (MHPSS) programme. We present a theory-driven quantitative analysis of the quality of 40 MHPSS programmes, mostly implemented in European disaster settings. The objective is to measure quality domains recognized as relevant in the literature and to empirically test associations. During the EU project "Operationalizing Psychosocial Support in Crisis" (OPSIC) an evaluation survey was designed and developed for this purpose and completed by 40 MHPSS programme coordinators involved in different mass emergencies and disasters. We analysed the survey data in two steps. Firstly, we used the data to operationalize quality domains of a MHPSS programme, tested constructs and assessed their internal consistency reliability. A total of 26 out of 44 survey items clustered into three of the four domains identified within the theoretical framework: "planning and delivery system" (Cronbach's alpha 0.82); "general evaluation criteria" (Cronbach's alpha 0.82); and "essential psychosocial principles" (Cronbach's alpha 0.75). "Measures and interventions applied", theoretically a potential fourth domain, could not be confirmed to empirically cluster together. Secondly, several models with associations between domains and measures and interventions were tested and compared. The model with the best fit suggests that in MHPSS programmes with a higher planning and delivery systems score, a larger number of measures and interventions from evidence-informed guidelines are applied. In such programmes, coordinators are more positive about general evaluation criteria and the realization of essential psychosocial principles. Moreover, the analyses showed that some measures and interventions are more likely to be applied in programmes with more evolved planning and delivery systems, yet for most measures and interventions the likelihood of being applied is not linked to planning and delivery system status, nor to coordinator perceptions concerning psychosocial principles and evaluation criteria. Further research is necessary to validate and expand the findings and to learn more about success factors and obstacles for MHPSS programme implementation.
NASA Technical Reports Server (NTRS)
Kumar, D.
1980-01-01
The computer program AFTBDY generates a body fitted curvilinear coordinate system for a wedge curved after body. This wedge curved after body is being used in an experimental program. The coordinate system generated by AFTBDY is used to solve 3D compressible N.S. equations. The coordinate system in the physical plane is a cartesian x,y,z system, whereas, in the transformed plane a rectangular xi, eta, zeta system is used. The coordinate system generated is such that in the transformed plane coordinate spacing in the xi, eta, zeta direction is constant and equal to unity. The physical plane coordinate lines in the different regions are clustered heavily or sparsely depending on the regions where physical quantities to be solved for by the N.S. equations have high or low gradients. The coordinate distribution in the physical plane is such that x stays constant in eta and zeta direction, whereas, z stays constant in xi and eta direction. The desired distribution in x and z is input to the program. Consequently, only the y-coordinate is solved for by the program AFTBDY.
Estevan, Isaac; Freedman Silvernail, Julia; Jandacka, Daniel; Falco, Coral
2016-09-01
The initial stance position (ISP) has been observed as a factor affecting the execution technique during taekwondo kicks. In the present study, authors aimed to analyse a roundhouse kick to the chest by measuring movement coordination and the variability of coordination and comparing this across the different ISP (0°, 45° and 90°). Eight experienced taekwondo athletes performed consecutive kicking trials in random order from every of the three relative positions. The execution was divided into three phases (stance, first swing and second swing phase). A motion capture system was used to measure athletes' angular displacement of pelvis and thigh. A modified vector coding technique was used to quantify the coordination of the segments which contributed to the overall movement. The variability of this coordination (CV) for each ISP was also calculated. Comparative analysis showed that during the stance phase in the transverse plane, athletes coordinated movement of the trunk and thigh with a higher frequency of in-phase and lower frequency of exclusive thigh rotation in the 0° stance than the 90° stance position (P < 0.05). CV was also influenced by the different ISP. During the first swing and the majority of the second swing phase, predominant in-phase coordination of the pelvis and thigh was observed. Including exercises that require in-phase movement could not only help athletes to acquire coordination stability but also efficiency. The existence of a constraint such as ISP implies an increase of the variability when the athletes have to kick from ISP they are not used to adopt (i.e., 0° and 90° ISP) as an evidence of adaptability in the athletes' execution technique.
Image Tiling for Profiling Large Objects
NASA Technical Reports Server (NTRS)
Venkataraman, Ajit; Schock, Harold; Mercer, Carolyn R.
1992-01-01
Three dimensional surface measurements of large objects arc required in a variety of industrial processes. The nature of these measurements is changing as optical instruments arc beginning to replace conventional contact probes scanned over the objects. A common characteristic of the optical surface profilers is the trade off between measurement accuracy and field of view. In order to measure a large object with high accuracy, multiple views arc required. An accurate transformation between the different views is needed to bring about their registration. In this paper, we demonstrate how the transformation parameters can be obtained precisely by choosing control points which lie in the overlapping regions of the images. A good starting point for the transformation parameters is obtained by having a knowledge of the scanner position. The selection of the control points arc independent of the object geometry. By successively recording multiple views and obtaining transformation with respect to a single coordinate system, a complete physical model of an object can be obtained. Since all data arc in the same coordinate system, it can thus be used for building automatic models for free form surfaces.
3D space positioning and image feature extraction for workpiece
NASA Astrophysics Data System (ADS)
Ye, Bing; Hu, Yi
2008-03-01
An optical system of 3D parameters measurement for specific area of a workpiece has been presented and discussed in this paper. A number of the CCD image sensors are employed to construct the 3D coordinate system for the measured area. The CCD image sensor of the monitoring target is used to lock the measured workpiece when it enters the field of view. The other sensors, which are placed symmetrically beam scanners, measure the appearance of the workpiece and the characteristic parameters. The paper established target image segmentation and the image feature extraction algorithm to lock the target, based on the geometric similarity of objective characteristics, rapid locking the goal can be realized. When line laser beam scan the tested workpiece, a number of images are extracted equal time interval and the overlapping images are processed to complete image reconstruction, and achieve the 3D image information. From the 3D coordinate reconstruction model, the 3D characteristic parameters of the tested workpiece are gained. The experimental results are provided in the paper.
NASA Astrophysics Data System (ADS)
Rückwardt, M.; Göpfert, A.; Correns, M.; Schellhorn, M.; Linß, G.
2010-07-01
Coordinate measuring machines are high precession all-rounder in three dimensional measuring. Therefore the versatility of parameters and expandability of additionally hardware is very comprehensive. Consequently you need much expert knowledge of the user and mostly a lot of advanced information about the measuring object. In this paper a coordinate measuring machine and a specialized measuring machine are compared at the example of the measuring of eyeglass frames. For this case of three dimensional measuring challenges the main focus is divided into metrological and economical aspects. At first there is shown a fully automated method for tactile measuring of this abstract form. At second there is shown a comparison of the metrological characteristics of a coordinate measuring machine and a tracer for eyeglass frames. The result is in favour to the coordinate measuring machine. It was not surprising in these aspects. At last there is shown a comparison of the machine in front of the economical aspects.
Multipole Structure and Coordinate Systems
ERIC Educational Resources Information Center
Burko, Lior M.
2007-01-01
Multipole expansions depend on the coordinate system, so that coefficients of multipole moments can be set equal to zero by an appropriate choice of coordinates. Therefore, it is meaningless to say that a physical system has a nonvanishing quadrupole moment, say, without specifying which coordinate system is used. (Except if this moment is the…
A feasibility study of hand kinematics for EVA analysis using magnetic resonance imaging
NASA Technical Reports Server (NTRS)
Dickenson, Rueben D.; Lorenz, Christine H.; Peterson, Steven W.; Strauss, Alvin M.; Main, John A.
1992-01-01
A new method of analyzing the kinematics of joint motion is developed. Magnetic Resonance Imaging (MRI) offers several distinct advantages. Past methods of studying anatomic joint motion have usually centered on four approaches. These methods are x-ray projection, goniometric linkage analysis, sonic digitization, and landmark measurement of photogrammetry. Of these four, only x-ray is applicable for in vivo studies. The remaining three methods utilize other types of projections of inter-joint measurements, which can cause various types of error. MRI offers accuracy in measurement due to its tomographic nature (as opposed to projection) without the problems associated with x-ray dosage. Once the data acquisition of MR images was complete, the images were processed using a 3D volume rendering workstation. The metacarpalphalangeal (MCP) joint of the left index finger was selected and reconstructed into a three-dimensional graphic display. From the reconstructed volumetric images, measurements of the angles of movement of the applicable bones were obtained and processed by analyzing the screw motion of the MCP joint. Landmark positions were chosen at distinctive locations of the joint at fixed image threshold intensity levels to ensure repeatability. The primarily two dimensional planar motion of this joint was then studied using a method of constructing coordinate systems using three (or more) points. A transformation matrix based on a world coordinate system described the location and orientation of a local target coordinate system. Future research involving volume rendering of MRI data focusing on the internal kinematics of the hand's individual ligaments, cartilage, tendons, etc. will follow. Its findings will show the applicability of MRI to joint kinematics for gaining further knowledge of the hand-glove (power assisted) design for extravehicular activity (EVA).
Status of research and development in coordinate-measurement technology
NASA Astrophysics Data System (ADS)
Dich, L. Z.; Latyev, S. M.
1994-09-01
This paper discusses problems involved in developing and operating coordinate-measuring machines. The status of this area of precision instrumentation is analyzed. These problems are made critical not only by the requirements of the machine-tool industry but also by those of the microelectronics industry, both of which use coordinate tables, step-up gears, and other equipment in which precise coordinate measurements are necessary.
Lower-Limb Joint Coordination Pattern in Obese Subjects
Ranavolo, Alberto; Donini, Lorenzo M.; Mari, Silvia; Serrao, Mariano; Silvetti, Alessio; Iavicoli, Sergio; Cava, Edda; Asprino, Rosa; Pinto, Alessandro; Draicchio, Francesco
2013-01-01
The coordinative pattern is an important feature of locomotion that has been studied in a number of pathologies. It has been observed that adaptive changes in coordination patterns are due to both external and internal constraints. Obesity is characterized by the presence of excess mass at pelvis and lower-limb areas, causing mechanical constraints that central nervous system could manage modifying the physiological interjoint coupling relationships. Since an altered coordination pattern may induce joint diseases and falls risk, the aim of this study was to analyze whether and how coordination during walking is affected by obesity. We evaluated interjoint coordination during walking in 25 obese subjects as well as in a control group. The time-distance parameters and joint kinematics were also measured. When compared with the control group, obese people displayed a substantial similarity in joint kinematic parameters and some differences in the time-distance and in the coupling parameters. Obese subjects revealed higher values in stride-to-stride intrasubjects variability in interjoint coupling parameters, whereas the coordinative mean pattern was unaltered. The increased variability in the coupling parameters is associated with an increased risk of falls and thus should be taken into account when designing treatments aimed at restoring a normal locomotion pattern. PMID:23484078
Spatial correlation of the dynamic propensity of a glass-forming liquid
NASA Astrophysics Data System (ADS)
Razul, M. Shajahan G.; Matharoo, Gurpreet S.; Poole, Peter H.
2011-06-01
We present computer simulation results on the dynamic propensity (as defined by Widmer-Cooper et al 2004 Phys. Rev. Lett. 93 135701) in a Kob-Andersen binary Lennard-Jones liquid system consisting of 8788 particles. We compute the spatial correlation function for the dynamic propensity as a function of both the reduced temperature T, and the time scale on which the particle displacements are measured. For T <= 0.6, we find that non-zero correlations occur at the largest length scale accessible in our system. We also show that a cluster-size analysis of particles with extremal values of the dynamic propensity, as well as 3D visualizations, reveal spatially correlated regions that approach the size of our system as T decreases, consistently with the behavior of the spatial correlation function. Next, we define and examine the 'coordination propensity', the isoconfigurational average of the coordination number of the minority B particles around the majority A particles. We show that a significant correlation exists between the spatial fluctuations of the dynamic and coordination propensities. In addition, we find non-zero correlations of the coordination propensity occurring at the largest length scale accessible in our system for all T in the range 0.466 < T < 1.0. We discuss the implications of these results for understanding the length scales of dynamical heterogeneity in glass-forming liquids.
VRACK: measuring pedal kinematics during stationary bike cycling.
Farjadian, Amir B; Kong, Qingchao; Gade, Venkata K; Deutsch, Judith E; Mavroidis, Constantinos
2013-06-01
Ankle impairment and lower limb asymmetries in strength and coordination are common symptoms for individuals with selected musculoskeletal and neurological impairments. The virtual reality augmented cycling kit (VRACK) was designed as a compact mechatronics system for lower limb and mobility rehabilitation. The system measures interaction forces and cardiac activity during cycling in a virtual environment. The kinematics measurement was added to the system. Due to the constrained problem definition, the combination of inertial measurement unit (IMU) and Kalman filtering was recruited to compute the optimal pedal angular displacement during dynamic cycling exercise. Using a novel benchmarking method the accuracy of IMU-based kinematics measurement was evaluated. Relatively accurate angular measurements were achieved. The enhanced VRACK system can serve as a rehabilitation device to monitor biomechanical and physiological variables during cycling on a stationary bike.
NASA Technical Reports Server (NTRS)
Smith, G. A.
1975-01-01
The attitude of a spacecraft is determined by specifying independent parameters which relate the spacecraft axes to an inertial coordinate system. Sensors which measure angles between spin axis and other vectors directed to objects or fields external to the spacecraft are discussed. For the spin-stabilized spacecraft considered, the spin axis is constant over at least an orbit, but separate solutions based on sensor angle measurements are different due to propagation of errors. Sensor-angle solution methods are described which minimize the propagated errors by making use of least squares techniques over many sensor angle measurements and by solving explicitly (in closed form) for the spin axis coordinates. These methods are compared with star observation solutions to determine if satisfactory accuracy is obtained by each method.
Development of an S-band cavity Beam Position Monitor for ATF2
NASA Astrophysics Data System (ADS)
Heo, A.; Kim, E.-S.; Kim, H.; Son, D.; Honda, Y.; Tauchi, T.
2013-04-01
We have developed an S-band cavity Beam Position Monitor (BPM) in order to measure the position of an electron beam in the final focus area at ATF2, which is the test facility for the final focus design for the International Linear Collider (ILC). The lattice of the ILC Beam Delivery System (BDS) has been modified, requiring a larger physical aperture of 40 mm in the final focus area. The beam orbit measurement in this area is now covered with high resolution S-Band cavity BPMs. In this paper we summarize the design of the cavity BPM and the first experimental results. The calibration slopes were measured as 0.87 counts/μm in the x-coordinate direction and 1.16 counts/μm in the y-coordinate direction.
New installation for inclined EAS investigations
NASA Astrophysics Data System (ADS)
Zadeba, E. A.; Ampilogov, N. V.; Barbashina, N. S.; Bogdanov, A. G.; Borisov, A. A.; Chernov, D. V.; Dushkin, L. I.; Fakhrutdinov, R. M.; Kokoulin, R. P.; Kompaniets, K. G.; Kozhin, A. S.; Ovchinnikov, V. V.; Ovechkin, A. S.; Petrukhin, A. A.; Shutenko, V. V.; Volkov, N. S.; Vorobjev, V. S.; Yashin, I. I.
2017-06-01
The large-scale coordinate-tracking detector TREK for registration of inclined EAS is being developed in MEPhI. The detector is based on multiwire drift chambers from the neutrino experiment at the IHEP U-70 accelerator. Their key advantages are a large effective area (1.85 m2), a good coordinate and angular resolution with a small number of measuring channels. The detector will be operated as part of the experimental complex NEVOD, in particular, jointly with a Cherenkov water detector (CWD) with a volume of 2000 cubic meters and the coordinate detector DECOR. The first part of the detector named Coordinate-Tracking Unit based on the Drift Chambers (CTUDC), representing two coordinate planes of 8 drift chambers in each, has been developed and mounted on opposite sides of the CWD. It has the same principle of joint operation with the NEVOD-DECOR triggering system and the same drift chambers alignment, so the main features of the TREK detector will be examined. Results of the CTUDC development and a joint operation with NEVOD-DECOR complex are presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gary S. Groenewold; Jean-Jacques Gaumet
2011-12-01
Coordination complexes containing Ce(III) and tri-n-butyl phosphate (TBP) in the 1+, 2+ and 3+ charge states were generated using desorption electrospray ionization (DESI) mass spectrometry, in which the analyte solutions were supplied via a target capillary orthogonally situated with respect to the electrospray. Comparison with direct electrospray (ESI) showed that the same coordination complexes were produced in each experiment, and could be described by the general formula [Ce(NO3)m=0-2(TBP)n](3-m)+. This result indicates that DESI has utility for measuring metal speciation for metal ligand solutions where the gas-phase complexes generated by ESI have been correlated with solution speciation. Such an application wouldmore » be useful for analyses where it is desirable to limit the total amount of metal being handled, or that have solvent systems that are not readily amenable to ESI. Both the direct ESI and DESI mass spectra showed similar trends with respect to the TBP:Ce ratio, viz. high values tend to favor formation of a larger fraction of the 1+ species, and the 2+ and 3+ species become relatively more important as the ratio is decreased. Within individual charge state ion envelopes, lower TBP:Ce ratios produce coordination complexes with fewer ligands, a trend also seen using both approaches. These trends again point toward strong similarity between the direct ESI and DESI analyses of the metal-ligand solutions. The DESI experiments were less sensitive for measuring the coordination complexes compared to the direct ESI experiments, by a factor of 10 - 100 depending on whether minimum detectable concentration or absolute ion abundances were considered. Nevertheless, mid-picomolar quantities of coordination complexes were measured using the target capillary, indicating that sensitivity would be sufficient for measuring species in many industrial separations processes.« less
The Graphical Cadastre Problem in Turkey: The Case of Trabzon Province.
Demir, Osman; Çoruhlu, Yakup Emre
2008-09-11
Cadastral projects in Turkey have been accelerated in recent years by the involvement of the private sector. These projects aim at completing the country's cadastre, along with producing bases in standards that could be a foundation for Land Registry and Cadastre Information System (LRCIS). It is possible to produce cadastral data with today's technological means. In this context, three dimensional cadastre data can be properly produced, especially in digital cadastre projects with the required point accuracy. Nevertheless this is not enough for LRCIS. The cadastre bases that have been produced so far by different methods with different scales and bases, with or without coordinates, should also be converted into digital form based on National Basic GPS Network of Turkey (NBGN) in required point-location accuracy. As the result of evaluation of graphical cadastre bases produced without coordinates, actual land measurements, and information obtained from sheets and field book data together, it was found out that there are significant base problems in the graphical maps. These bases, comprising 20% of Turkey's cadastre constitutes the most important bottleneck of completing the country's cadastre. In the scope of this paper, the possibilities of converting the field book measurement values of graphic cadastre bases into digital forms in national coordinate system by comparing them with actual land measurements are investigated, along with Turkey's Cadastre and its problems.
The Graphical Cadastre Problem in Turkey: The Case of Trabzon Province
Demir, Osman; Çoruhlu, Yakup Emre
2008-01-01
Cadastral projects in Turkey have been accelerated in recent years by the involvement of the private sector. These projects aim at completing the country's cadastre, along with producing bases in standards that could be a foundation for Land Registry and Cadastre Information System (LRCIS). It is possible to produce cadastral data with today's technological means. In this context, three dimensional cadastre data can be properly produced, especially in digital cadastre projects with the required point accuracy. Nevertheless this is not enough for LRCIS. The cadastre bases that have been produced so far by different methods with different scales and bases, with or without coordinates, should also be converted into digital form based on National Basic GPS Network of Turkey (NBGN) in required point-location accuracy. As the result of evaluation of graphical cadastre bases produced without coordinates, actual land measurements, and information obtained from sheets and field book data together, it was found out that there are significant base problems in the graphical maps. These bases, comprising 20% of Turkey's cadastre constitutes the most important bottleneck of completing the country's cadastre. In the scope of this paper, the possibilities of converting the field book measurement values of graphic cadastre bases into digital forms in national coordinate system by comparing them with actual land measurements are investigated, along with Turkey's Cadastre and its problems. PMID:27873830
Tracking Objects with Networked Scattered Directional Sensors
NASA Astrophysics Data System (ADS)
Plarre, Kurt; Kumar, P. R.
2007-12-01
We study the problem of object tracking using highly directional sensors—sensors whose field of vision is a line or a line segment. A network of such sensors monitors a certain region of the plane. Sporadically, objects moving in straight lines and at a constant speed cross the region. A sensor detects an object when it crosses its line of sight, and records the time of the detection. No distance or angle measurements are available. The task of the sensors is to estimate the directions and speeds of the objects, and the sensor lines, which are unknown a priori. This estimation problem involves the minimization of a highly nonconvex cost function. To overcome this difficulty, we introduce an algorithm, which we call "adaptive basis algorithm." This algorithm is divided into three phases: in the first phase, the algorithm is initialized using data from six sensors and four objects; in the second phase, the estimates are updated as data from more sensors and objects are incorporated. The third phase is an optional coordinated transformation. The estimation is done in an "ad-hoc" coordinate system, which we call "adaptive coordinate system." When more information is available, for example, the location of six sensors, the estimates can be transformed to the "real-world" coordinate system. This constitutes the third phase.
Method of the Determination of Exterior Orientation of Sensors in Hilbert Type Space.
Stępień, Grzegorz
2018-03-17
The following article presents a new isometric transformation algorithm based on the transformation in the newly normed Hilbert type space. The presented method is based on so-called virtual translations, already known in advance, of two relative oblique orthogonal coordinate systems-interior and exterior orientation of sensors-to a common, known in both systems, point. Each of the systems is translated along its axis (the systems have common origins) and at the same time the angular relative orientation of both coordinate systems is constant. The translation of both coordinate systems is defined by the spatial norm determining the length of vectors in the new Hilbert type space. As such, the displacement of two relative oblique orthogonal systems is reduced to zero. This makes it possible to directly calculate the rotation matrix of the sensor. The next and final step is the return translation of the system along an already known track. The method can be used for big rotation angles. The method was verified in laboratory conditions for the test data set and measurement data (field data). The accuracy of the results in the laboratory test is on the level of 10 -6 of the input data. This confirmed the correctness of the assumed calculation method. The method is a further development of the author's 2017 Total Free Station (TFS) transformation to several centroids in Hilbert type space. This is the reason why the method is called Multi-Centroid Isometric Transformation-MCIT. MCIT is very fast and enables, by reducing to zero the translation of two relative oblique orthogonal coordinate systems, direct calculation of the exterior orientation of the sensors.
Recommended coordinate systems for thin spherocylindrical lenses.
Deal, F C; Toop, J
1993-05-01
Because the set of thin spherocylindrical lenses forms a vector space, any such lens can be expressed in terms of its cartesian coordinates with respect to whatever set of basis lenses we may choose. Two types of cartesian coordinate systems have become prominent, those having coordinates associated with the lens power matrix and those having coordinates associated with the Humphrey Vision Analyzer. This paper emphasizes the value of a particular cartesian coordinate system of the latter type, and the cylindrical coordinate system related to it, by showing how it can simplify the trigonometry of adding lenses and how it preserves symmetry in depicting the sets of all spherical lenses, all Jackson crossed-cylinders, and all cylindrical lenses. It also discusses appropriate coordinates for keeping statistics on lenses and shows that an easy extension of the lens vector space to include general optical systems is not possible.
Dimensional coordinate measurements: application in characterizing cervical spine motion
NASA Astrophysics Data System (ADS)
Zheng, Weilong; Li, Linan; Wang, Shibin; Wang, Zhiyong; Shi, Nianke; Xue, Yuan
2014-06-01
Cervical spine as a complicated part in the human body, the form of its movement is diverse. The movements of the segments of vertebrae are three-dimensional, and it is reflected in the changes of the angle between two joint and the displacement in different directions. Under normal conditions, cervical can flex, extend, lateral flex and rotate. For there is no relative motion between measuring marks fixed on one segment of cervical vertebra, the cervical vertebrae with three marked points can be seen as a body. Body's motion in space can be decomposed into translational movement and rotational movement around a base point .This study concerns the calculation of dimensional coordinate of the marked points pasted to the human body's cervical spine by an optical method. Afterward, these measures will allow the calculation of motion parameters for every spine segment. For this study, we choose a three-dimensional measurement method based on binocular stereo vision. The object with marked points is placed in front of the CCD camera. Through each shot, we will get there two parallax images taken from different cameras. According to the principle of binocular vision we can be realized three-dimensional measurements. Cameras are erected parallelly. This paper describes the layout of experimental system and a mathematical model to get the coordinates.
DC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dragicevic, Tomislav; Lu, Xiaonan; Vasquez, Juan
2015-01-01
This paper presents a review of control strategies, stability analysis, and stabilization techniques for dc microgrids (MGs). Overall control is systematically classified into local and coordinated control levels according to respective functionalities in each level. As opposed to local control, which relies only on local measurements, some line of communication between units needs to be made available in order to achieve the coordinated control. Depending on the communication method, three basic coordinated control strategies can be distinguished, i.e., decentralized, centralized, and distributed control. Decentralized control can be regarded as an extension of the local control since it is also basedmore » exclusively on local measurements. In contrast, centralized and distributed control strategies rely on digital communication technologies. A number of approaches using these three coordinated control strategies to achieve various control objectives are reviewed in this paper. Moreover, properties of dc MG dynamics and stability are discussed. This paper illustrates that tightly regulated point-of-load converters tend to reduce the stability margins of the system since they introduce negative impedances, which can potentially oscillate with lightly damped power supply input filters. It is also demonstrated that how the stability of the whole system is defined by the relationship of the source and load impedances, referred to as the minor loop gain. Several prominent specifications for the minor loop gain are reviewed. Finally, a number of active stabilization techniques are presented.« less
NASA Astrophysics Data System (ADS)
Chen, Chao; Gao, Nan; Wang, Xiangjun; Zhang, Zonghua
2018-05-01
Three-dimensional (3D) shape measurement based on fringe pattern projection techniques has been commonly used in various fields. One of the remaining challenges in fringe pattern projection is that camera sensor saturation may occur if there is a large range of reflectivity variation across the surface that causes measurement errors. To overcome this problem, a novel fringe pattern projection method is proposed to avoid image saturation and maintain high-intensity modulation for measuring shiny surfaces by adaptively adjusting the pixel-to-pixel projection intensity according to the surface reflectivity. First, three sets of orthogonal color fringe patterns and a sequence of uniform gray-level patterns with different gray levels are projected onto a measured surface by a projector. The patterns are deformed with respect to the object surface and captured by a camera from a different viewpoint. Subsequently, the optimal projection intensity at each pixel is determined by fusing different gray levels and transforming the camera pixel coordinate system into the projector pixel coordinate system. Finally, the adapted fringe patterns are created and used for 3D shape measurement. Experimental results on a flat checkerboard and shiny objects demonstrate that the proposed method can measure shiny surfaces with high accuracy.
[Financing, organization, costs and services performance of the Argentinean health sub-systems.
Yavich, Natalia; Báscolo, Ernesto Pablo; Haggerty, Jeannie
2016-01-01
To analyze the relationship between health system financing and services organization models with costs and health services performance in each of Rosario's health sub-systems. The financing and organization models were characterized using secondary data. Costs were calculated using the WHO/SHA methodology. Healthcare quality was measured by a household survey (n=822). Public subsystem:Vertically integrated funding and primary healthcare as a leading strategy to provide services produced low costs and individual-oriented healthcare but with weak accessibility conditions and comprehensiveness. Private subsystem: Contractual integration and weak regulatory and coordination mechanisms produced effects opposed to those of the public sub-system. Social security: Contractual integration and strong regulatory and coordination mechanisms contributed to intermediate costs and overall high performance. Each subsystem financing and services organization model had a strong and heterogeneous influence on costs and health services performance.
Research and design of photovoltaic power monitoring system based on Zig Bee
NASA Astrophysics Data System (ADS)
Zhu, Lijuan; Yun, Zhonghua; Bianbawangdui; Bianbaciren
2018-01-01
In order to monitor and study the impact of environmental parameters on photovoltaic cells, a photovoltaic cell monitoring system based on ZigBee is designed. The system uses ZigBee wireless communication technology to achieve real-time acquisition of P-I-V curves and environmental parameters of terminal nodes, and transfer the data to the coordinator, the coordinator communicates with the STM32 through the serial port. In addition, STM32 uses the serial port to transfer data to the host computer written by LabVIEW, and the collected data is displayed in real time, as well as stored in the background database. The experimental results show that the system has a stable performance, accurate measurement, high sensitivity, high reliability, can better realize real-time collection of photovoltaic cell characteristics and environmental parameters.
NASA Astrophysics Data System (ADS)
Bewley, Thomas
2015-11-01
Accurate long-term forecasts of the path and intensity of hurricanes are imperative to protect property and save lives. Accurate estimations and forecasts of the spread of large-scale contaminant plumes, such as those from Deepwater Horizon, Fukushima, and recent volcanic eruptions in Iceland, are essential for assessing environment impact, coordinating remediation efforts, and in certain cases moving folks out of harm's way. The challenges in estimating and forecasting such systems include: (a) environmental flow modeling, (b) high-performance real-time computing, (c) assimilating measured data into numerical simulations, and (d) acquiring in-situ data, beyond what can be measured from satellites, that is maximally relevant for reducing forecast uncertainty. This talk will focus on new techniques for addressing (c) and (d), namely, data assimilation and adaptive observation, in both hurricanes and large-scale environmental plumes. In particular, we will present a new technique for the energy-efficient coordination of swarms of sensor-laden balloons for persistent, in-situ, distributed, real-time measurement of developing hurricanes, leveraging buoyancy control only (coupled with the predictable and strongly stratified flowfield within the hurricane). Animations of these results are available at http://flowcontrol.ucsd.edu/3dhurricane.mp4 and http://flowcontrol.ucsd.edu/katrina.mp4. We also will survey our unique hybridization of the venerable Ensemble Kalman and Variational approaches to large-scale data assimilation in environmental flow systems, and how essentially the dual of this hybrid approach may be used to solve the adaptive observation problem in a uniquely effective and rigorous fashion.
Reference coordinate systems: An update. Supplement 11
NASA Technical Reports Server (NTRS)
Mueller, Ivan I.
1988-01-01
A common requirement for all geodetic investigations is a well-defined coordinate system attached to the earth in some prescribed way, as well as a well-defined inertial coordinate system in which the motions of the terrestrial frame can be monitored. The paper deals with the problems encountered when establishing such coordinate systems and the transformations between them. In addition, problems related to the modeling of the deformable earth are discussed. This paper is an updated version of the earlier work, Reference Coordinate Systems for Earth Dynamics: A Preview, by the author.
Femur-mounted navigation system for the arthroscopic treatment of femoroacetabular impingement
NASA Astrophysics Data System (ADS)
Park, S. H.; Hwang, D. S.; Yoon, Y. S.
2013-07-01
Femoroacetabular impingement stems from an abnormal shape of the acetabulum and proximal femur. It is treated by resection of damaged soft tissue and by the shaping of bone to resemble normal features. The arthroscopic treatment of femoroacetabular impingement has many advantages, including minimal incisions, rapid recovery, and less pain. However, in some cases, revision is needed owing to the insufficient resection of damaged bone from a misreading of the surgical site. The limited view of arthroscopy is the major reason for the complications. In this research, a navigation method for the arthroscopic treatment of femoroacetabular impingement is developed. The proposed navigation system consists of femur attachable measurement device and user interface. The bone mounted measurement devices measure points on head-neck junction for registration and position of surgical instrument. User interface shows the three-dimensional model of patient's femur and surgical instrument position that is tracked by measurement device. Surgeon can know the three-dimensional anatomical structure of hip joint and surgical instrument position on surgical site using navigation system. Surface registration was used to obtain relation between patient's coordinate at the surgical site and coordinate of three-dimensional model of femur. In this research, we evaluated the proposed navigation system using plastic model bone. It is expected that the surgical tool tracking position accuracy will be less than 1 mm.
Allsop, Matthew J; Kite, Suzanne; McDermott, Sarah; Penn, Naomi; Millares-Martin, Pablo; Bennett, Michael I
2016-01-01
Background: The need to improve coordination of care at end of life has driven electronic palliative care coordination systems implementation across the United Kingdom and internationally. No approaches for evaluating electronic palliative care coordination systems use in practice have been developed. Aim: This study outlines and applies an evaluation framework for examining how and when electronic documentation of advance care planning is occurring in end of life care services. Design: A pragmatic, formative process evaluation approach was adopted. The evaluation drew on the Project Review and Objective Evaluation methodology to guide the evaluation framework design, focusing on clinical processes. Setting/participants: Data were extracted from electronic palliative care coordination systems for 82 of 108 general practices across a large UK city. All deaths (n = 1229) recorded on electronic palliative care coordination systems between April 2014 and March 2015 were included to determine the proportion of all deaths recorded, median number of days prior to death that key information was recorded and observations about routine data use. Results: The evaluation identified 26.8% of all deaths recorded on electronic palliative care coordination systems. The median number of days to death was calculated for initiation of an electronic palliative care coordination systems record (31 days), recording a patient’s preferred place of death (8 days) and entry of Do Not Attempt Cardiopulmonary Resuscitation decisions (34 days). Where preferred and actual place of death was documented, these were matching for 75% of patients. Anomalies were identified in coding used during data entry on electronic palliative care coordination systems. Conclusion: This study reports the first methodology for evaluating how and when electronic palliative care coordination systems documentation is occurring. It raises questions about what can be drawn from routine data collected through electronic palliative care coordination systems and outlines considerations for future evaluation. Future evaluations should consider work processes of health professionals using electronic palliative care coordination systems. PMID:27507636
Allsop, Matthew J; Kite, Suzanne; McDermott, Sarah; Penn, Naomi; Millares-Martin, Pablo; Bennett, Michael I
2017-05-01
The need to improve coordination of care at end of life has driven electronic palliative care coordination systems implementation across the United Kingdom and internationally. No approaches for evaluating electronic palliative care coordination systems use in practice have been developed. This study outlines and applies an evaluation framework for examining how and when electronic documentation of advance care planning is occurring in end of life care services. A pragmatic, formative process evaluation approach was adopted. The evaluation drew on the Project Review and Objective Evaluation methodology to guide the evaluation framework design, focusing on clinical processes. Data were extracted from electronic palliative care coordination systems for 82 of 108 general practices across a large UK city. All deaths ( n = 1229) recorded on electronic palliative care coordination systems between April 2014 and March 2015 were included to determine the proportion of all deaths recorded, median number of days prior to death that key information was recorded and observations about routine data use. The evaluation identified 26.8% of all deaths recorded on electronic palliative care coordination systems. The median number of days to death was calculated for initiation of an electronic palliative care coordination systems record (31 days), recording a patient's preferred place of death (8 days) and entry of Do Not Attempt Cardiopulmonary Resuscitation decisions (34 days). Where preferred and actual place of death was documented, these were matching for 75% of patients. Anomalies were identified in coding used during data entry on electronic palliative care coordination systems. This study reports the first methodology for evaluating how and when electronic palliative care coordination systems documentation is occurring. It raises questions about what can be drawn from routine data collected through electronic palliative care coordination systems and outlines considerations for future evaluation. Future evaluations should consider work processes of health professionals using electronic palliative care coordination systems.
Weeks, Douglas L; Polello, Jennifer M; Hansen, Daniel T; Keeney, Benjamin J; Conrad, Douglas A
2014-01-01
Not all primary care clinics are prepared to implement care coordination services for chronic conditions, such as diabetes. Understanding true capacity to coordinate care is an important first-step toward establishing effective and efficient care coordination. Yet, we could identify no diabetes-specific instruments to systematically assess readiness and/or status of primary care clinics to engage in diabetes care coordination. This report describes the development and initial validation of the Diabetes Care Coordination Readiness Assessment (DCCRA), which is intended to measure primary care clinic readiness to coordinate care for adult patients with diabetes. The instrument was developed through iterative item generation within a framework of five domains of care coordination: Organizational Capacity, Care Coordination, Clinical Management, Quality Improvement, and Technical Infrastructure. Validation data was collected on 39 primary care clinics. Content validity, inter-rater reliability, internal consistency, and construct validity of the 49-item instrument were assessed. Inter-rater agreement indices per item ranged from 0.50 to 1.0. Cronbach's alpha of the entire instrument was 0.964, and for the five domain scales ranged from 0.688 to 0.961. Clinics with existing care coordinators were rated as more ready to support care coordination than clinics without care coordinators for the entire DCCRA and for each domain, supporting construct validity. As providers increasingly attempt to adopt patient-centered approaches, introduction of the DCCRA is timely and appropriate for assisting clinics with identifying gaps in provision of care coordination services. The DCCRA's strengths include promising psychometric properties. A valid measure of diabetes care coordination readiness should be useful in diabetes program evaluation, assistance with quality improvement initiatives, and measurement of patient-centered care in research.
75 FR 75532 - Shipping Coordinating Committee; Notice of Committee Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-03
...; --Validation of model training courses; --Unlawful practices associated with certificates of competency... Recommendations for entering enclosed spaces aboard ships; --Development of model procedures for executing shipboard emergency measures; --Development of training standards for recovery systems; --Development of...
[Coupling coordinated development of ecological-economic system in Loess Plateau].
Zhang, Qing-Feng; Wu, Fa-Qi; Wang, Li; Wang, Jian
2011-06-01
Based on system theory, a coupling coordinated development model of ecological-economic system in Loess Plateau was established, and the evaluation criteria and basic types of the coordinated development of the ecological-economic system were proposed. The county-level coupling coordinated development of the ecological-economic system was also discussed, based on the local characteristics. The interactions between the ecological and economic systems in Loess Plateau could be divided into four stages, i.e., seriously disordered development stage, mild-disordered development stage, low-level coordinated development stage, and high level well-coordinated development stage. At each stage, there existed a cyclic process of profit and loss-antagonist-running-dominant-synchronous development. The coupling development degree of the ecological-economic system in Loess Plateau was overall at a lower level, being about 62.7% of the counties at serious disorder, 30.1% of the counties at mild disorder, and 7.1% of the counties at low but coordinated level. The coupling development degree based on the model established in this study could better reflect the current social-economic and ecological environment situations, especially the status of coordination. To fully understand the coupling of ecological-economic system and to adopt appropriate development mode would be of significance to promote the county-level coordinated development in Loess Plateau.
A Model-Based Approach for the Measurement of Eye Movements Using Image Processing
NASA Technical Reports Server (NTRS)
Sung, Kwangjae; Reschke, Millard F.
1997-01-01
This paper describes a video eye-tracking algorithm which searches for the best fit of the pupil modeled as a circular disk. The algorithm is robust to common image artifacts such as the droopy eyelids and light reflections while maintaining the measurement resolution available by the centroid algorithm. The presented algorithm is used to derive the pupil size and center coordinates, and can be combined with iris-tracking techniques to measure ocular torsion. A comparison search method of pupil candidates using pixel coordinate reference lookup tables optimizes the processing requirements for a least square fit of the circular disk model. This paper includes quantitative analyses and simulation results for the resolution and the robustness of the algorithm. The algorithm presented in this paper provides a platform for a noninvasive, multidimensional eye measurement system which can be used for clinical and research applications requiring the precise recording of eye movements in three-dimensional space.
Concept of AHRS Algorithm Designed for Platform Independent Imu Attitude Alignment
NASA Astrophysics Data System (ADS)
Tomaszewski, Dariusz; Rapiński, Jacek; Pelc-Mieczkowska, Renata
2017-12-01
Nowadays, along with the advancement of technology one can notice the rapid development of various types of navigation systems. So far the most popular satellite navigation, is now supported by positioning results calculated with use of other measurement system. The method and manner of integration will depend directly on the destination of system being developed. To increase the frequency of readings and improve the operation of outdoor navigation systems, one will support satellite navigation systems (GPS, GLONASS ect.) with inertial navigation. Such method of navigation consists of several steps. The first stage is the determination of initial orientation of inertial measurement unit, called INS alignment. During this process, on the basis of acceleration and the angular velocity readings, values of Euler angles (pitch, roll, yaw) are calculated allowing for unambiguous orientation of the sensor coordinate system relative to external coordinate system. The following study presents the concept of AHRS (Attitude and heading reference system) algorithm, allowing to define the Euler angles.The study were conducted with the use of readings from low-cost MEMS cell phone sensors. Subsequently the results of the study were analyzed to determine the accuracy of featured algorithm. On the basis of performed experiments the legitimacy of developed algorithm was stated.
Rare earth niobate coordination polymers
NASA Astrophysics Data System (ADS)
Muniz, Collin N.; Patel, Hiral; Fast, Dylan B.; Rohwer, Lauren E. S.; Reinheimer, Eric W.; Dolgos, Michelle; Graham, Matt W.; Nyman, May
2018-03-01
Rare-earth (RE) coordination polymers are infinitely tailorable to yield luminescent materials for various applications. Here we described the synthesis of a heterometallic rare-earth coordination compound ((CH3)2SO)3(RE)NbO(C2O4)3((CH3)2SO) = dimethylsulfoxide, DMSO, (C2O2= oxalate), (RE=La, Ce, Pr, Nd, Sm, Eu, Gd, Tb). The structure was obtained from single crystal X-ray diffraction of the La analogue. The Nb˭O and DMSO terminal-bonding character guides assembly of an open framework structure with noncentrosymmetric RE-coordination geometry, and large spacing between the RE centers. A second structure was observed by PXRD for the smaller rare earths (Dy, Ho, Er, Yb); this structure has not yet been determined. The materials were further characterized using FTIR, and photoluminescence measurements. Characteristic excitation and emission transitions were observed for RE = Nd, Sm, Eu, and Tb. Quantum yield (QY) measurements were performed by exciting Eu and Tb analoges at 394 nm (QY 66%) and 464 nm (QY 71%) for Eu; and 370 nm (QY=40%) for Tb. We attribute the high QY and bright luminescence to two main structure-function properties of the system; namely the absence of water in the structure, and absence of concentration quenching.
Improved spatial calibration for the CXRS system on EAST
NASA Astrophysics Data System (ADS)
Yin, X. H.; Li, Y. Y.; Fu, J.; Jiang, D.; Feng, S. Y.; Gu, Y. Q.; Cheng, Y.; Lyu, B.; Shi, Y. J.; Ye, M. Y.; Wan, B. N.
2016-11-01
A Charge eXchange Recombination Spectroscopy (CXRS) diagnostic system has been developed to measure profiles of ion temperature and rotation since 2014 on EAST. Several techniques have been developed to improve the spatial calibration of the CXRS diagnostic. The sightline location was obtained by measuring the coordinates of three points on each sightline using an articulated flexible coordinate measuring arm when the vessel was accessible. After vacuum pumping, the effect of pressure change in the vacuum vessel was evaluated by observing the movement of the light spot from back-illuminated sightlines on the first wall using the newly developed articulated inspection arm. In addition, the rotation of the periscope after vacuum pumping was derived by using the Doppler shift of neutral beam emission spectra without magnetic field. Combining these techniques, improved spatial calibration was implemented to provide a complete and accurate description of the EAST CXRS system. Due to the effects of the change of air pressure, a ˜0.4° periscope rotation, yielding a ˜20 mm movement of the major radius of observation positions to the lower field side, was derived. Results of Zeeman splitting of neutral beam emission spectra with magnetic field also showed good agreement with the calibration results.
Beshears, David L.; Batsell, Stephen G.; Abercrombie, Robert K.; Scudiere, Matthew B.; White, Clifford P.
2007-12-04
An asset identification and information infrastructure management (AI3M) device having an automated identification technology system (AIT), a Transportation Coordinators' Automated Information for Movements System II (TC-AIMS II), a weigh-in-motion system (WIM-II), and an Automated Air Load Planning system (AALPS) all in electronic communication for measuring and calculating actual asset characteristics, either statically or in-motion, and further calculating an actual load plan.
Multistability and metastability: understanding dynamic coordination in the brain
Kelso, J. A. Scott
2012-01-01
Multistable coordination dynamics exists at many levels, from multifunctional neural circuits in vertebrates and invertebrates to large-scale neural circuitry in humans. Moreover, multistability spans (at least) the domains of action and perception, and has been found to place constraints upon, even dictating the nature of, intentional change and the skill-learning process. This paper reviews some of the key evidence for multistability in the aforementioned areas, and illustrates how it has been measured, modelled and theoretically understood. It then suggests how multistability—when combined with essential aspects of coordination dynamics such as instability, transitions and (especially) metastability—provides a platform for understanding coupling and the creative dynamics of complex goal-directed systems, including the brain and the brain–behaviour relation. PMID:22371613
Tsuneda, Masato; Nishio, Teiji; Saito, Akito; Tanaka, Sodai; Suzuki, Tatsuhiko; Kawahara, Daisuke; Matsushita, Keiichiro; Nishio, Aya; Ozawa, Shuichi; Karasawa, Kumiko; Nagata, Yasushi
2018-06-01
High accuracy of the beam-irradiated position is required for high-precision radiation therapy such as stereotactic body radiation therapy (SBRT), volumetric modulated arc therapy (VMAT), and intensity modulated radiation therapy (IMRT). Users generally perform the verification of the mechanical and radiation isocenters using the star shot test and the Winston Lutz test that allow evaluation of the displacement at the isocenter. However, these methods are unable to evaluate directly and quantitatively the sagging angle that is caused by the weight of the gantry itself along the gantry rotation axis. In addition, the verification of the central axis of the irradiated beam that is not dependent at the isocenter is needed for the mechanical quality assurance of a nonisocentric irradiation technique. In this study, we have developed a prototype system for the verification of three-dimensional (3D) beam alignment and we have verified the system concept for 3D isocentricity. Our system allows detection of the central axis in 3D coordinates and evaluation of the irradiated oblique angle to the gantry rotation axis, i.e., the sagging angle. In order to measure the central axis of the irradiated beam in 3D coordinates, we constructed the prototype verification system consisting of a column-shaped plastic scintillator (CoPS), a truncated cone-shaped mirror (TCsM), and a cooled charged-coupled device (CCD) camera. This verification system was irradiated with 6-MV photon beams and the scintillation light was measured using the CCD camera. The central axis on the axial plane (two-dimensional (2D) central axis) was acquired from the integration of the scintillation light along the major axis of the CoPS, and the central axis in 3D coordinates (3D central axis) was acquired from two curve-shaped profiles which were reflected by the TCsM. We verified the calculation accuracy of the gantry rotation axis, θ z . Additionally, we calculated the 3D central axis and the sagging angle at each gantry angle. We acquired the measurement images composed of the 2D central axis and the two curve-shaped profiles. The relationship between the irradiated and measured angles with respect to the gantry rotation axis had good linearity. The mean and standard deviation of the difference between the irradiated and measured angles were 0.012 and 0.078 degrees, respectively. The size of the 2D and 3D radiation isocenters were 0.470 and 0.652 mm on the axial plane and in 3D coordinates, respectively. The sagging angles were -0.31, 0.39, and 0.38 degrees at the gantry angles of 0, 180, and 180E degrees, respectively. We developed a novel verification system, designated as the "kompeito shot test system," to verify the 3D beam alignment. This system concept works for both verification of the 3D isocentricity and the direct evaluation of the sagging angle. Next, we want to improve the aspects of this system, such as the shape and the type of scintillator, to increase the system accuracy and nonisocentric beam alignment performance. © 2018 American Association of Physicists in Medicine.
TOPEX orbit determination using GPS signals plus a sidetone ranging system
NASA Technical Reports Server (NTRS)
Bender, P. L.; Larden, D. R.
1982-01-01
The GPS orbit determination was studied to see how well the radial coordinate for altimeter satellites such as TOPEX could be found by on board measurements of GPS signals, including the reconstructed carrier phase. The inclusion on altimeter satellites of an additional high accuracy tracking system is recommended. It is suggested that a sidetone ranging system is used in conjunction with TRANET 2 beacons.
Building Student and Family-Centered Care Coordination Through Ongoing Delivery System Design.
Baker, Dian; Anderson, Lori; Johnson, Jody
2017-01-01
In 2016 the National Association of School Nurses released an updated framework for school nurse practice. One highlight of the new framework is 21st century care coordination. That is, moving beyond basic case management to a systems-level approach for delivery of school health services. The framework broadly applies the term care coordination to include direct care and communication across systems. School nurses are often engaged in efforts to create school health care homes that serve as an axis of coordination for students and families between primary care offices and the schools. Effective care coordination requires that the school nurses not only know the principles of traditional case management but also understand complex systems that drive effective care coordination. The outcome of a system-level approach is enhanced access to services in an integrated health care delivery system that includes the school nurse as an integral member of the school's health care team. This article presents a comprehensive, system-level model of care coordination for school nurse leadership and practice.
NASA Technical Reports Server (NTRS)
Coulter, Phillip; Beaton, Alexander; Gum, Jeffrey S.; Hadjimichael, Theodore J.; Hayden, Joseph E.; Hummel, Susann; Hylan, Jason E.; Lee, David; Madison, Timothy J.; Maszkiewicz, Michael;
2014-01-01
The James Webb Space Telescope science instruments are in the final stages of being integrated into the Integrated Science Instrument Module (ISIM) element. Each instrument is tied into a common coordinate system through mechanical references that are used for optical alignment and metrology within ISIM after element-level assembly. In addition, a set of ground support equipment (GSE) consisting of large, precisely calibrated, ambient, and cryogenic structures are used as alignment references and gauges during various phases of integration and test (I&T). This GSE, the flight instruments, and ISIM structure feature different types of complimentary metrology targeting. These GSE targets are used to establish and track six degrees of freedom instrument alignment during I&T in the vehicle coordinate system (VCS). This paper describes the optomechanical metrology conducted during science instrument integration and alignment in the Spacecraft Systems Development and Integration Facility (SSDIF) cleanroom at NASA Goddard Space Flight Center (GSFC). The measurement of each instrument's ambient entrance pupil location in the telescope coordinate system is discussed. The construction of the database of target locations and the development of metrology uncertainties is also discussed.
A topological coordinate system for the diamond cubic grid.
Čomić, Lidija; Nagy, Benedek
2016-09-01
Topological coordinate systems are used to address all cells of abstract cell complexes. In this paper, a topological coordinate system for cells in the diamond cubic grid is presented and some of its properties are detailed. Four dependent coordinates are used to address the voxels (triakis truncated tetrahedra), their faces (hexagons and triangles), their edges and the points at their corners. Boundary and co-boundary relations, as well as adjacency relations between the cells, can easily be captured by the coordinate values. Thus, this coordinate system is apt for implementation in various applications, such as visualizations, morphological and topological operations and shape analysis.
Development of one-shot aspheric measurement system with a Shack-Hartmann sensor.
Furukawa, Yasunori; Takaie, Yuichi; Maeda, Yoshiki; Ohsaki, Yumiko; Takeuchi, Seiji; Hasegawa, Masanobu
2016-10-10
We present a measurement system for a rotationally symmetric aspheric surface that is designed for accurate and high-volume measurements. The system uses the Shack-Hartmann sensor and is capable of measuring aspheres with a maximum diameter of 90 mm in one shot. In our system, a reference surface, made with the same aspheric parameter as the test surface, is prepared. The test surface is recovered as the deviation from the reference surface using a figure-error reconstruction algorithm with a ray coordinate and angle variant table. In addition, we developed a method to calibrate the rotationally symmetric system error. These techniques produce stable measurements and high accuracy. For high-throughput measurements, a single measurement scheme and auto alignment are implemented; they produce a 4.5 min measurement time, including calibration and alignment. In this paper, we introduce the principle and calibration method of our system. We also demonstrate that our system achieved an accuracy better than 5.8 nm RMS and a repeatability of 0.75 nm RMS by comparing our system's aspheric measurement results with those of a probe measurement machine.
NASA Astrophysics Data System (ADS)
Habre, Samer
2017-01-01
Covariational reasoning has been the focus of many studies but only a few looked into this reasoning in the polar coordinate system. In fact, research on student's familiarity with polar coordinates and graphing in the polar coordinate system is scarce. This paper examines the challenges that students face when plotting polar curves using the corresponding plot in the Cartesian plane. In particular, it examines how students coordinate the covariation in the polar coordinate system with the covariation in the Cartesian one. The research, which was conducted in a sophomore level Calculus class at an American university operating in Lebanon, investigates in addition the challenges when students synchronize the reasoning between the two coordinate systems. For this, the mental actions that students engage in when performing covariational tasks are examined. Results show that coordinating the value of one polar variable with changes in the other was well achieved. Coordinating the direction of change of one variable with changes in the other variable was more challenging for students especially when the radial distance r is negative.
NASA Astrophysics Data System (ADS)
Mazurova, Elena; Mikhaylov, Aleksandr
2013-04-01
The selenocentric network of objects setting the coordinate system on the Moon, with the origin coinciding with the mass centre and axes directed along the inertia axes can become one of basic elements of the coordinate-time support for lunar navigation with use of cartographic materials and control objects. A powerful array of highly-precise and multiparameter information obtained by modern space vehicles allows one to establish Lunar Reference Frames (LRF) of an essentially another accuracy. Here, a special role is played by the results of scanning the lunar surface by the Lunar Reconnaissance Orbiter(LRO) American mission. The coordinates of points calculated only from the results of laser scanning have high enough accuracy of position definition with respect to each other, but it is possible to check up the real accuracy of spatial tie and improve the coordinates only by a network of points whose coordinates are computed both from laser scanning and other methods too, for example, by terrestrial laser location, space photogrammetry methods, and so on. The paper presents the algorithm for transforming selenocentric coordinate systems and the accuracy estimation of changing from one lunar coordinate system to another one. Keywords: selenocentric coordinate system, coordinate-time support.
Analysis on the dynamic error for optoelectronic scanning coordinate measurement network
NASA Astrophysics Data System (ADS)
Shi, Shendong; Yang, Linghui; Lin, Jiarui; Guo, Siyang; Ren, Yongjie
2018-01-01
Large-scale dynamic three-dimension coordinate measurement technique is eagerly demanded in equipment manufacturing. Noted for advantages of high accuracy, scale expandability and multitask parallel measurement, optoelectronic scanning measurement network has got close attention. It is widely used in large components jointing, spacecraft rendezvous and docking simulation, digital shipbuilding and automated guided vehicle navigation. At present, most research about optoelectronic scanning measurement network is focused on static measurement capacity and research about dynamic accuracy is insufficient. Limited by the measurement principle, the dynamic error is non-negligible and restricts the application. The workshop measurement and positioning system is a representative which can realize dynamic measurement function in theory. In this paper we conduct deep research on dynamic error resources and divide them two parts: phase error and synchronization error. Dynamic error model is constructed. Based on the theory above, simulation about dynamic error is carried out. Dynamic error is quantized and the rule of volatility and periodicity has been found. Dynamic error characteristics are shown in detail. The research result lays foundation for further accuracy improvement.
NASA Astrophysics Data System (ADS)
Wang, Pengyao; Chen, Xiangguang; Yang, Kai; Liu, Xuejiao
2017-01-01
To improve the measuring efficiency of width and thickness of tire tread in the process of automobile tire production, the actual condition for the tire production process is analyzed, and a fast online measurement system based on moving tire tread of tire specifications is established in this paper. The coordinate data of tire tread profile is acquired by 3D laser sensor, and we use C# language for programming which is an object-oriented programming language to complete the development of client program. The system with laser sensor can provide real-time display of tire tread profile and the data to require in the process of tire production. Experimental results demonstrate that the measuring precision of the system is <= 1mm, it can meet the measurement requirements of the production process, and the system has the characteristics of convenient installation and testing, system stable operation.
Fast mapping algorithm of lighting spectrum and GPS coordinates for a large area
NASA Astrophysics Data System (ADS)
Lin, Chih-Wei; Hsu, Ke-Fang; Hwang, Jung-Min
2016-09-01
In this study, we propose a fast rebuild technology for evaluating light quality in large areas. Outdoor light quality, which is measured by illuminance uniformity and the color rendering index, is difficult to conform after improvement. We develop an algorithm for a lighting quality mapping system and coordinates using a micro spectrometer and GPS tracker integrated with a quadcopter or unmanned aerial vehicle. After cruising at a constant altitude, lighting quality data is transmitted and immediately mapped to evaluate the light quality in a large area.
Local gravitational physics of the Hubble expansion. Einstein's equivalence principle in cosmology
NASA Astrophysics Data System (ADS)
Kopeikin, Sergei M.
2015-01-01
We study physical consequences of the Hubble expansion of Friedmann-Lemaıtre-Robertson-Walker (FLRW) manifold on measurement of space, time and light propagation in the local inertial frame. We use the results of this study to analyse the Solar System radar ranging and Doppler tracking experiments and time synchronization. FLRW manifold is covered by the coordinates ( t, y i ), where t is the cosmic time coinciding with the proper time of the Hubble observers and identified with the barycentric coordinate time (TCB) used in ephemeris astronomy. We introduce the local inertial coordinates x α = ( x 0, x i ) in the vicinity of a world line of a Hubble observer with the help of a special conformal transformation that respects the local equivalence between the tangent and FLRW manifold. The local inertial metric is Minkowski flat and is materialized by the congruence of time-like geodesics of static observers being at rest with respect to the local spatial coordinates x i . The static observers are equipped with the ideal clocks measuring their own proper time which is synchronized with the cosmic time t measured by the Hubble observer. We consider the geodesic motion of test particles and notice that the local coordinate time x 0 = x 0( t) taken as a parameter along the world line of the particle, is a function of Hubble's observer time t. This function changes smoothly from x 0 = t for a particle at rest (observer's clock), to x 0 = t + (1/2) Ht 2 for photons, where H is the Hubble constant. Thus, the motion of a test particle is non-uniform when its world line is parametrized by the cosmic time t. NASA JPL Orbit Determination Program operates under the assumption that the spacetime is asymptotically flat which presumes that the motion of light (after the Shapiro delay is excluded) is uniform with respect to the time t but it does not comply with the non-uniform motion of light on cosmological manifold. For this reason, the motion of light in the Solar System analysed with the Orbit Determination Program appears as having a systematic blue shift of frequency, of radio waves circulating in the Earth-spacecraft radio link. The magnitude of the anomalous blue shift of frequency is proportional to the Hubble constant H that may open an access to the measurement of this fundamental cosmological parameter in the Solar System radiowave experiments.
The Sensorimotor System Can Sculpt Behaviorally Relevant Representations for Motor Learning
2016-01-01
Abstract The coordinate system in which humans learn novel motor skills is controversial. The representation of sensorimotor skills has been extensively studied by examining generalization after learning perturbations specifically designed to be ambiguous as to their coordinate system. Recent studies have found that learning is not represented in any simple coordinate system and can potentially be accounted for by a mixed representation. Here, instead of probing generalization, which has led to conflicting results, we examine whether novel dynamics can be learned when explicitly and unambiguously presented in particular coordinate systems. Subjects performed center–out reaches to targets in the presence of a force field, while varying the orientation of their hand (i.e., the wrist angle) across trials. Different groups of subjects experienced force fields that were explicitly presented either in Cartesian coordinates (field independent of hand orientation), in object coordinates (field rotated with hand orientation), or in anti-object coordinates (field rotated counter to hand orientation). Subjects learned to represent the dynamics when presented in either Cartesian or object coordinates, learning these as well as an ambiguous force field. However, learning was slower for the object-based dynamics and substantially impaired for the anti-object presentation. Our results show that the motor system is able to tune its representation to at least two natural coordinate systems but is impaired when the representation of the task does not correspond to a behaviorally relevant coordinate system. Our results show that the motor system can sculpt its representation through experience to match those of natural tasks. PMID:27588304
ARCHAEO-SCAN: Portable 3D shape measurement system for archaeological field work
NASA Astrophysics Data System (ADS)
Knopf, George K.; Nelson, Andrew J.
2004-10-01
Accurate measurement and thorough documentation of excavated artifacts are the essential tasks of archaeological fieldwork. The on-site recording and long-term preservation of fragile evidence can be improved using 3D spatial data acquisition and computer-aided modeling technologies. Once the artifact is digitized and geometry created in a virtual environment, the scientist can manipulate the pieces in a virtual reality environment to develop a "realistic" reconstruction of the object without physically handling or gluing the fragments. The ARCHAEO-SCAN system is a flexible, affordable 3D coordinate data acquisition and geometric modeling system for acquiring surface and shape information of small to medium sized artifacts and bone fragments. The shape measurement system is being developed to enable the field archaeologist to manually sweep the non-contact sensor head across the relic or artifact surface. A series of unique data acquisition, processing, registration and surface reconstruction algorithms are then used to integrate 3D coordinate information from multiple views into a single reference frame. A novel technique for automatically creating a hexahedral mesh of the recovered fragments is presented. The 3D model acquisition system is designed to operate from a standard laptop with minimal additional hardware and proprietary software support. The captured shape data can be pre-processed and displayed on site, stored digitally on a CD, or transmitted via the Internet to the researcher's home institution.
Cephalometric landmark detection in dental x-ray images using convolutional neural networks
NASA Astrophysics Data System (ADS)
Lee, Hansang; Park, Minseok; Kim, Junmo
2017-03-01
In dental X-ray images, an accurate detection of cephalometric landmarks plays an important role in clinical diagnosis, treatment and surgical decisions for dental problems. In this work, we propose an end-to-end deep learning system for cephalometric landmark detection in dental X-ray images, using convolutional neural networks (CNN). For detecting 19 cephalometric landmarks in dental X-ray images, we develop a detection system using CNN-based coordinate-wise regression systems. By viewing x- and y-coordinates of all landmarks as 38 independent variables, multiple CNN-based regression systems are constructed to predict the coordinate variables from input X-ray images. First, each coordinate variable is normalized by the length of either height or width of an image. For each normalized coordinate variable, a CNN-based regression system is trained on training images and corresponding coordinate variable, which is a variable to be regressed. We train 38 regression systems with the same CNN structure on coordinate variables, respectively. Finally, we compute 38 coordinate variables with these trained systems from unseen images and extract 19 landmarks by pairing the regressed coordinates. In experiments, the public database from the Grand Challenges in Dental X-ray Image Analysis in ISBI 2015 was used and the proposed system showed promising performance by successfully locating the cephalometric landmarks within considerable margins from the ground truths.
Variations in data collection can influence outcome measures of BMI measuring programmes.
Townsend, Nick; Rutter, Harry; Foster, Charlie
2011-10-01
The World Health Organization (WHO) promotes the surveillance of obesity prevalence through standardized and harmonized surveillance systems. However, variations in data collection between countries, or between coordinating regions in countries can affect outcome measures. Multilevel analysis of 2007/08 National Child Measurement Programme (NCMP) data estimating the relationship between BMI z-score and data collection variations within coordinating regions whilst adjusting for individual-level and school-level variables. The 2007/08 NCMP collected height and weight measurements for 478,381 Reception year pupils (4-5-year-olds) and 496,297 year 6 pupils (10-11-year-olds) from 17,279 primary schools in 152 data collection coordinating regions in England. Data collection variables accounted for 29.7% of the regional variation in BMI z-score for Reception year pupils but only 5.3% for the older Year 6 pupils. Digit preference in the rounding of weight measurements had the greatest impact of all the data collection variables, explaining 26.4% of the regional variation in BMI z-score for Reception year pupils and 4.0% for Year 6 pupils. Although variations in data collection may have a small effect on individual measurements their impact can be magnified when scaled up to regional or national figures. All measurement programmes must regularly identify and minimize variations in data collection to improve accuracy of outcome measures. These factors include those identified within this study: participation and opt out rates, the time in the year the measurements are taken and the recording of measurements to the correct decimal place.
Time-Coordination Strategies and Control Laws for Multi-Agent Unmanned Systems
NASA Technical Reports Server (NTRS)
Puig-Navarro, Javier; Hovakimyan, Naira; Allen, B. Danette
2017-01-01
Time-critical coordination tools for unmanned systems can be employed to enforce the type of temporal constraints required in terminal control areas, ensure minimum distance requirements among vehicles are satisfied, and successfully perform coordinated missions. In comparison with previous literature, this paper presents an ampler spectrum of coordination and temporal specifications for unmanned systems, and proposes a general control law that can enforce this range of constraints. The constraint classification presented con- siders the nature of the desired arrival window and the permissible coordination errors to define six different types of time-coordination strategies. The resulting decentralized coordination control law allows the vehicles to negotiate their speeds along their paths in response to information exchanged over the communication network. This control law organizes the different members in the fleet hierarchically per their behavior and informational needs as reference agent, leaders, and followers. Examples and simulation results for all the coordination strategies presented demonstrate the applicability and efficacy of the coordination control law for multiple unmanned systems.
Assessment of Survivability against Laser Threats. The ASALT-I Computer Program
1981-09-01
NUM4ER OF PAGES WHICH DO NOT REPRODUCE LEGIBLY. I - f ~ ~ ’ECUftITt CL.inWCATOM Or TII PAGEL Cu18.. De 3Sawe no"___VISA__________1""I REPORT...subsection. COORDINATE SYSTEMS The four coordinate systems used in the ASALT-I Model are de -I picted in Figure 2-1, where the subscripts on each axis identify...centroid in the Enc,’, inter Coordinate System 2i z-coordinate of the component centroid in the Encounter Coordinate System gy width of the component
Long-term observations of tropospheric ozone: GAW Measurement Guidelines
NASA Astrophysics Data System (ADS)
Tarasova, Oksana; Galbally, Ian E.; Schultz, Martin G.
2013-04-01
The Global Atmosphere Watch (GAW) Programme of the World Meteorological Organization (WMO) coordinates long-term observations of the chemical composition and physical properties of the atmosphere which are relevant for understanding of atmospheric chemistry and climate change. Atmospheric observations of reactive gases (tropospheric ozone, carbon monoxide, volatile organic compounds and nitrogen oxides) coordinated by the GAW Programme complement local and regional scale air quality monitoring efforts. As part of the GAW quality assurance (QA) system detailed measurement guidelines for atmospheric trace species are developed by international expert teams at irregular intervals. The most recent report focuses on continuous in-situ measurements of ozone in the troposphere, performed in particular at continental or island sites with altitudes ranging from sea level to mountain tops. Data Quality Objectives (DQOs) are defined for different applications of the data (e.g. trend analysis and verification of global model forecasts). These DQOs include a thorough discussion of the tolerable level of measurement uncertainty and data completeness. The guidelines present the best practices and practical arrangements adopted by the GAW Programme in order to enable the GAW station network to approach or achieve the defined tropospheric ozone DQOs. The document includes information on the selection of station and measurement locations, required skills and training of staff, recommendations on the measurement technique and the necessary equipment to perform highest quality measurements, rules for conducting the measurements, preparing the data and archiving them, and more. Much emphasis is given to discussions about how to ensure the quality of the data through tracing calibrations back to primary standards, proper calibration and data analysis, etc. In the GAW Programme the QA system is implemented through Central Facilities (Central Calibration Laboratories, World and Regional Calibration Centers and World Data Centers), Scientific Advisory Groups and GAW Training and Education Center. These bodies support primary standards, provide calibration and data archiving facilities, coordinate comparison campaigns, perform stations audit, provide documentation and training of personnel.
Zlateva, Ianita; Anderson, Daren; Coman, Emil; Khatri, Khushbu; Tian, Terrence; Fifield, Judith
2015-06-07
Community health centers are increasingly embracing the Patient Centered Medical Home (PCMH) model to improve quality, access to care, and patient experience while reducing healthcare costs. Care coordination (CC) is an important element of the PCMH model, but implementation and measurability of CC remains a problem within the outpatient setting. Assessing CC is an integral component of quality monitoring in health care systems. This study developed and validated the Medical Home Care Coordination Survey (MHCCS), to fill the gap in assessing CC in primary care from the perspectives of patients and their primary healthcare teams. We conducted a review of relevant literature and existing care coordination instruments identified by bibliographic search and contact with experts. After identifying all care coordination domains that could be assessed by primary healthcare team members and patients, we developed a conceptual model. Potentially appropriate items from existing published CC measures, along with newly developed items, were matched to each domain for inclusion. A modified Delphi approach was used to establish content validity. Primary survey data was collected from 232 patients with care transition and/or complex chronic illness needs from the Community Health Center, Inc. and from 164 staff members from 12 community health centers across the country via mail, phone and online survey. The MHCCS was validated for internal consistency, reliability, discriminant and convergent validity. This study was conducted at the Community Health Center, Inc. from January 15, 2012 to July 15, 2014. The 13-item MHCCS - Patient and the 32-item MHCCS - Healthcare Team were developed and validated. Exploratory Structural Equation Modeling was used to test the hypothesized domain structure. Four CC domains were confirmed from the patient group and eight were confirmed from the primary healthcare team group. All domains had high reliability (Cronbach's α scores were above 0.8). Patients experience the ultimate output of care coordination services, but primary healthcare staff members are best primed to perceive many of the structural elements of care coordination. The proactive measurement and monitoring of the core domains from both perspectives provides a richer body of information for the continuous improvement of care coordination services. The MHCCS shows promise as a valid and reliable assessment of these CC efforts.
NASA Technical Reports Server (NTRS)
Lewandowski, Wlodzimierz W.; Petit, Gerard; Thomas, Claudine; Weiss, Marc A.
1990-01-01
Over intercontinental distances, the accuracy of The Global Positioning System (GPS) time transfers ranges from 10 to 20 ns. The principal error sources are the broadcast ionospheric model, the broadcast ephemerides and the local antenna coordinates. For the first time, the three major error sources for GPS time transfer can be reduced simultaneously for a particular time link. Ionospheric measurement systems of the National Institute of Standards and Technology (NIST) type are now operating on a regular basis at the National Institute of Standards and Technology in Boulder and at the Paris Observatory in Paris. Broadcast ephemerides are currently recorded for time-transfer tracks between these sites, this being necessary for using precise ephemerides. At last, corrected local GPS antenna coordinates are now introduced in GPS receivers at both sites. Shown here is the improvement in precision for this long-distance time comparison resulting from the reduction of these three error sources.
Asymmetric interlimb transfer of concurrent adaptation to opposing dynamic forces
Miall, R. C.; Woolley, D. G.
2007-01-01
Interlimb transfer of a novel dynamic force has been well documented. It has also been shown that unimanual adaptation to opposing novel environments is possible if they are associated with different workspaces. The main aim of this study was to test if adaptation to opposing velocity dependent viscous forces with one arm could improve the initial performance of the other arm. The study also examined whether this interlimb transfer occurred across an extrinsic, spatial, coordinative system or an intrinsic, joint based, coordinative system. Subjects initially adapted to opposing viscous forces separated by target location. Our measure of performance was the correlation between the speed profiles of each movement within a force condition and an ‘average’ trajectory within null force conditions. Adaptation to the opposing forces was seen during initial acquisition with a significantly improved coefficient in epoch eight compared to epoch one. We then tested interlimb transfer from the dominant to non-dominant arm (D → ND) and vice-versa (ND → D) across either an extrinsic or intrinsic coordinative system. Interlimb transfer was only seen from the dominant to the non-dominant limb across an intrinsic coordinative system. These results support previous studies involving adaptation to a single dynamic force but also indicate that interlimb transfer of multiple opposing states is possible. This suggests that the information available at the level of representation allowing interlimb transfer can be more intricate than a general movement goal or a single perceived directional error. PMID:17703286
Bala, Sukhen; Sen Bishwas, Mousumi; Pramanik, Bhaskar; Khanra, Sumit; Fromm, Katharina M; Poddar, Pankaj; Mondal, Raju
2015-09-08
Employment of two different pyridyl-pyrazolyl-based ligands afforded three octanuclear lanthanide(III) (Ln = Dy, Tb) cage compounds and one hexanuclear neodymium(III) coordination cage, exhibiting versatile molecular architectures including a butterfly core. Relatively less common semirigid pyridyl-pyrazolyl-based asymmetric ligand systems show an interesting trend of forming polynuclear lanthanide cage complexes with different coordination environments around the metal centers. It is noteworthy here that construction of lanthanide complex itself is a challenging task in a ligand system as soft N-donor rich as pyridyl-pyrazol. We report herein some lanthanide complexes using ligand containing only one or two O-donors compare to five N-coordinating sites. The resultant multinuclear lanthanide complexes show interesting magnetic and spectroscopic features originating from different spatial arrangements of the metal ions. Alternating current (ac) susceptibility measurements of the two dysprosium complexes display frequency- and temperature-dependent out-of-phase signals in zero and 0.5 T direct current field, a typical characteristic feature of single-molecule magnet (SMM) behavior, indicating different energy reversal barriers due to different molecular topologies. Another aspect of this work is the occurrence of the not-so-common SMM behavior of the terbium complex, further confirmed by ac susceptibility measurement.
NASA Astrophysics Data System (ADS)
Xia, Renbo; Hu, Maobang; Zhao, Jibin; Chen, Songlin; Chen, Yueling
2018-06-01
Multi-camera vision systems are often needed to achieve large-scale and high-precision measurement because these systems have larger fields of view (FOV) than a single camera. Multiple cameras may have no or narrow overlapping FOVs in many applications, which pose a huge challenge to global calibration. This paper presents a global calibration method for multi-cameras without overlapping FOVs based on photogrammetry technology and a reconfigurable target. Firstly, two planar targets are fixed together and made into a long target according to the distance between the two cameras to be calibrated. The relative positions of the two planar targets can be obtained by photogrammetric methods and used as invariant constraints in global calibration. Then, the reprojection errors of target feature points in the two cameras’ coordinate systems are calculated at the same time and optimized by the Levenberg–Marquardt algorithm to find the optimal solution of the transformation matrix between the two cameras. Finally, all the camera coordinate systems are converted to the reference coordinate system in order to achieve global calibration. Experiments show that the proposed method has the advantages of high accuracy (the RMS error is 0.04 mm) and low cost and is especially suitable for on-site calibration.
3D reconstruction of a tree stem using video images and pulse distances
N. E. Clark
2002-01-01
This paper demonstrates how a 3D tree stem model can be reconstructed using video imagery combined with laser pulse distance measurements. Perspective projection is used to place the data collected with the portable video laser-rangefinding device into a real world coordinate system. This hybrid methodology uses a relatively small number of range measurements (compared...
Clinical Study of the 3D-Master Color System among the Spanish Population.
Gómez-Polo, Cristina; Gómez-Polo, Miguel; Martínez Vázquez de Parga, Juan Antonio; Celemín-Viñuela, Alicia
2017-01-12
To study whether the shades of the 3D-Master System were grouped and represented in the chromatic space according to the three-color coordinates of value, chroma, and hue. Maxillary central incisor color was measured on tooth surfaces through the Easyshade Compact spectrophotometer using 1361 participants aged between 16 and 89. The natural (not bleached teeth) color of the middle thirds was registered in the 3D-Master System nomenclature and in the CIELCh system. Principal component analysis and cluster analysis were applied. 75 colors of the 3D-Master System were found. The statistical analysis revealed the existence of 5 cluster groups. The centroid, the average of the 75 samples, in relation to lightness (L*) was 74.64, 22.87 for chroma (C*), and 88.85 for hue (h*). All of the clusters, except cluster 3, showed significant statistical differences with the centroid for the three-color coordinates (p <0.001). The results of this study indicated that 75 shades in the 3D-Master System were grouped into 5 clusters following coordinates L*, C*, and h* resulting from the dental spectrophotometer Vita Easyshade compact. The shades that composed each cluster did not belong to the same lightness color dimension groups. There was no special uniform chromatic distribution among the colors of the 3D-Master System. © 2017 by the American College of Prosthodontists.
Measurement of M²-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor.
Du, Yongzhao
2016-11-29
For asymmetric laser beams, the values of beam quality factor M x 2 and M y 2 are inconsistent if one selects a different coordinate system or measures beam quality with different experimental conditionals, even when analyzing the same beam. To overcome this non-uniqueness, a new beam quality characterization method named as M²-curve is developed. The M²-curve not only contains the beam quality factor M x 2 and M y 2 in the x -direction and y -direction, respectively; but also introduces a curve of M x α 2 versus rotation angle α of coordinate axis. Moreover, we also present a real-time measurement method to demonstrate beam propagation factor M²-curve with a modified self-referencing Mach-Zehnder interferometer based-wavefront sensor (henceforth SRI-WFS). The feasibility of the proposed method is demonstrated with the theoretical analysis and experiment in multimode beams. The experimental results showed that the proposed measurement method is simple, fast, and a single-shot measurement procedure without movable parts.
Measurement of M2-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor
Du, Yongzhao
2016-01-01
For asymmetric laser beams, the values of beam quality factor Mx2 and My2 are inconsistent if one selects a different coordinate system or measures beam quality with different experimental conditionals, even when analyzing the same beam. To overcome this non-uniqueness, a new beam quality characterization method named as M2-curve is developed. The M2-curve not only contains the beam quality factor Mx2 and My2 in the x-direction and y-direction, respectively; but also introduces a curve of Mxα2 versus rotation angle α of coordinate axis. Moreover, we also present a real-time measurement method to demonstrate beam propagation factor M2-curve with a modified self-referencing Mach-Zehnder interferometer based-wavefront sensor (henceforth SRI-WFS). The feasibility of the proposed method is demonstrated with the theoretical analysis and experiment in multimode beams. The experimental results showed that the proposed measurement method is simple, fast, and a single-shot measurement procedure without movable parts. PMID:27916845
Multiple Sensory-Motor Pathways Lead to Coordinated Visual Attention
Yu, Chen; Smith, Linda B.
2016-01-01
Joint attention has been extensively studied in the developmental literature because of overwhelming evidence that the ability to socially coordinate visual attention to an object is essential to healthy developmental outcomes, including language learning. The goal of the present study is to understand the complex system of sensory-motor behaviors that may underlie the establishment of joint attention between parents and toddlers. In an experimental task, parents and toddlers played together with multiple toys. We objectively measured joint attention – and the sensory-motor behaviors that underlie it – using a dual head-mounted eye-tracking system and frame-by-frame coding of manual actions. By tracking the momentary visual fixations and hand actions of each participant, we precisely determined just how often they fixated on the same object at the same time, the visual behaviors that preceded joint attention, and manual behaviors that preceded and co-occurred with joint attention. We found that multiple sequential sensory-motor patterns lead to joint attention. In addition, there are developmental changes in this multi-pathway system evidenced as variations in strength among multiple routes. We propose that coordinated visual attention between parents and toddlers is primarily a sensory-motor behavior. Skill in achieving coordinated visual attention in social settings – like skills in other sensory-motor domains – emerges from multiple pathways to the same functional end. PMID:27016038
Multiple Sensory-Motor Pathways Lead to Coordinated Visual Attention.
Yu, Chen; Smith, Linda B
2017-02-01
Joint attention has been extensively studied in the developmental literature because of overwhelming evidence that the ability to socially coordinate visual attention to an object is essential to healthy developmental outcomes, including language learning. The goal of this study was to understand the complex system of sensory-motor behaviors that may underlie the establishment of joint attention between parents and toddlers. In an experimental task, parents and toddlers played together with multiple toys. We objectively measured joint attention-and the sensory-motor behaviors that underlie it-using a dual head-mounted eye-tracking system and frame-by-frame coding of manual actions. By tracking the momentary visual fixations and hand actions of each participant, we precisely determined just how often they fixated on the same object at the same time, the visual behaviors that preceded joint attention and manual behaviors that preceded and co-occurred with joint attention. We found that multiple sequential sensory-motor patterns lead to joint attention. In addition, there are developmental changes in this multi-pathway system evidenced as variations in strength among multiple routes. We propose that coordinated visual attention between parents and toddlers is primarily a sensory-motor behavior. Skill in achieving coordinated visual attention in social settings-like skills in other sensory-motor domains-emerges from multiple pathways to the same functional end. Copyright © 2016 Cognitive Science Society, Inc.
A robotic system for researching social integration in honeybees.
Griparić, Karlo; Haus, Tomislav; Miklić, Damjan; Polić, Marsela; Bogdan, Stjepan
2017-01-01
In this paper, we present a novel robotic system developed for researching collective social mechanisms in a biohybrid society of robots and honeybees. The potential for distributed coordination, as observed in nature in many different animal species, has caused an increased interest in collective behaviour research in recent years because of its applicability to a broad spectrum of technical systems requiring robust multi-agent control. One of the main problems is understanding the mechanisms driving the emergence of collective behaviour of social animals. With the aim of deepening the knowledge in this field, we have designed a multi-robot system capable of interacting with honeybees within an experimental arena. The final product, stationary autonomous robot units, designed by specificaly considering the physical, sensorimotor and behavioral characteristics of the honeybees (lat. Apis mallifera), are equipped with sensing, actuating, computation, and communication capabilities that enable the measurement of relevant environmental states, such as honeybee presence, and adequate response to the measurements by generating heat, vibration and airflow. The coordination among robots in the developed system is established using distributed controllers. The cooperation between the two different types of collective systems is realized by means of a consensus algorithm, enabling the honeybees and the robots to achieve a common objective. Presented results, obtained within ASSISIbf project, show successful cooperation indicating its potential for future applications.
NASA Astrophysics Data System (ADS)
Kawaguchi, S.; Takemoto, M.; Osaka, K.; Nishibori, E.; Moriyoshi, C.; Kubota, Y.; Kuroiwa, Y.; Sugimoto, K.
2017-08-01
In this study, we developed a user-friendly automatic powder diffraction measurement system for Debye-Scherrer geometry using a capillary sample at beamline BL02B2 of SPring-8. The measurement system consists of six one-dimensional solid-state (MYTHEN) detectors, a compact auto-sampler, wide-range temperature control systems, and a gas handling system. This system enables to do the automatic measurement of temperature dependence of the diffraction patterns for multiple samples. We introduced two measurement modes in the MYTHEN system and developed new attachments for the sample environment such as a gas handling system. The measurement modes and the attachments can offer in situ and/or time-resolved measurements in an extended temperature range between 25 K and 1473 K and various gas atmospheres and pressures. The results of the commissioning and performance measurements using reference materials (NIST CeO2 674b and Si 640c), V2O3 and Ti2O3, and a nanoporous coordination polymer are presented.
NASA Astrophysics Data System (ADS)
Pang, Hongfeng; Zhu, XueJun; Pan, Mengchun; Zhang, Qi; Wan, Chengbiao; Luo, Shitu; Chen, Dixiang; Chen, Jinfei; Li, Ji; Lv, Yunxiao
2016-12-01
Misalignment error is one key factor influencing the measurement accuracy of geomagnetic vector measurement system, which should be calibrated with the difficulties that sensors measure different physical information and coordinates are invisible. A new misalignment calibration method by rotating a parallelepiped frame is proposed. Simulation and experiment result show the effectiveness of calibration method. The experimental system mainly contains DM-050 three-axis fluxgate magnetometer, INS (inertia navigation system), aluminium parallelepiped frame, aluminium plane base. Misalignment angles are calculated by measured data of magnetometer and INS after rotating the aluminium parallelepiped frame on aluminium plane base. After calibration, RMS error of geomagnetic north, vertical and east are reduced from 349.441 nT, 392.530 nT and 562.316 nT to 40.130 nT, 91.586 nT and 141.989 nT respectively.
Optical Testing of Retroreflectors for Cryogenic Applications
NASA Technical Reports Server (NTRS)
Ohl, Raymond G.; Frey, Bradley J.; Stock, Joseph M.; McMann, Joseph C.; Zukowiski, Tmitri J.
2010-01-01
A laser tracker (LT) is an important coordinate metrology tool that uses laser interferometry to determine precise distances to objects, points, or surfaces defined by an optical reference, such as a retroreflector. A retroreflector is a precision optic consisting of three orthogonal faces that returns an incident laser beam nearly exactly parallel to the incident beam. Commercial retroreflectors are designed for operation at room temperature and are specified by the divergence, or beam deviation, of the returning laser beam, usually a few arcseconds or less. When a retroreflector goes to extreme cold (.35 K), however, it could be anticipated that the precision alignment between the three faces and the surface figure of each face would be compromised, resulting in wavefront errors and beam divergence, degrading the accuracy of the LT position determination. Controlled tests must be done beforehand to determine survivability and these LT coordinate errors. Since conventional interferometer systems and laser trackers do not operate in vacuum or at cold temperatures, measurements must be done through a vacuum window, and care must be taken to ensure window-induced errors are negligible, or can be subtracted out. Retroreflector holders must be carefully designed to minimize thermally induced stresses. Changes in the path length and refractive index of the retroreflector have to be considered. Cryogenic vacuum testing was done on commercial solid glass retroreflectors for use on cryogenic metrology tasks. The capabilities to measure wavefront errors, measure beam deviations, and acquire laser tracker coordinate data were demonstrated. Measurable but relatively small increases in beam deviation were shown, and further tests are planned to make an accurate determination of coordinate errors.
Saraswat, Prabhav; MacWilliams, Bruce A; Davis, Roy B
2012-04-01
Several multi-segment foot models to measure the motion of intrinsic joints of the foot have been reported. Use of these models in clinical decision making is limited due to lack of rigorous validation including inter-clinician, and inter-lab variability measures. A model with thoroughly quantified variability may significantly improve the confidence in the results of such foot models. This study proposes a new clinical foot model with the underlying strategy of using separate anatomic and technical marker configurations and coordinate systems. Anatomical landmark and coordinate system identification is determined during a static subject calibration. Technical markers are located at optimal sites for dynamic motion tracking. The model is comprised of the tibia and three foot segments (hindfoot, forefoot and hallux) and inter-segmental joint angles are computed in three planes. Data collection was carried out on pediatric subjects at two sites (Site 1: n=10 subjects by two clinicians and Site 2: five subjects by one clinician). A plaster mold method was used to quantify static intra-clinician and inter-clinician marker placement variability by allowing direct comparisons of marker data between sessions for each subject. Intra-clinician and inter-clinician joint angle variability were less than 4°. For dynamic walking kinematics, intra-clinician, inter-clinician and inter-laboratory variability were less than 6° for the ankle and forefoot, but slightly higher for the hallux. Inter-trial variability accounted for 2-4° of the total dynamic variability. Results indicate the proposed foot model reduces the effects of marker placement variability on computed foot kinematics during walking compared to similar measures in previous models. Copyright © 2011 Elsevier B.V. All rights reserved.
Mastmeyer, André; Engelke, Klaus; Fuchs, Christina; Kalender, Willi A
2006-08-01
We have developed a new hierarchical 3D technique to segment the vertebral bodies in order to measure bone mineral density (BMD) with high trueness and precision in volumetric CT datasets. The hierarchical approach starts with a coarse separation of the individual vertebrae, applies a variety of techniques to segment the vertebral bodies with increasing detail and ends with the definition of an anatomic coordinate system for each vertebral body, relative to which up to 41 trabecular and cortical volumes of interest are positioned. In a pre-segmentation step constraints consisting of Boolean combinations of simple geometric shapes are determined that enclose each individual vertebral body. Bound by these constraints viscous deformable models are used to segment the main shape of the vertebral bodies. Volume growing and morphological operations then capture the fine details of the bone-soft tissue interface. In the volumes of interest bone mineral density and content are determined. In addition, in the segmented vertebral bodies geometric parameters such as volume or the length of the main axes of inertia can be measured. Intra- and inter-operator precision errors of the segmentation procedure were analyzed using existing clinical patient datasets. Results for segmented volume, BMD, and coordinate system position were below 2.0%, 0.6%, and 0.7%, respectively. Trueness was analyzed using phantom scans. The bias of the segmented volume was below 4%; for BMD it was below 1.5%. The long-term goal of this work is improved fracture prediction and patient monitoring in the field of osteoporosis. A true 3D segmentation also enables an accurate measurement of geometrical parameters that may augment the clinical value of a pure BMD analysis.
NASA Astrophysics Data System (ADS)
Koychev Demirov, Encho
1994-12-01
The paper presents a numerical solution of barotropic and two-layer eigen-oscillation problems for the Black Sea on a boundary fitted coordinate system. This solution is compared with model and empirical data obtained by other workers. Frequencies of the eigen-oscillations found by the numerical solution of spectral problem are compared with the data obtained by spectral analysis of the sea-level oscillations measured near the town of Achtopol and Cape Irakli in stormy sea on 17-21 February 1979. Extreme oscillations of the sea-level result from resonant amplifications of three eigenmodes of the Black Sea of 68.3 -1, 36.6 -1 and 27.3 -1 cycles h -1 frequency.
Managing clinical integration in integrated delivery systems: a framework for action.
Young, D W; Barrett, D
1997-01-01
An integrated delivery system (IDS) in healthcare must coordinate patient care across multiple functions, activities, and operating units. To achieve this clinical integration, senior management confronts many challenges. This paper uses a cross-functional-process (CFP) framework to discuss these challenges. There are ten CFPs that fall into three categories: planning processes (strategy formulation, program adaptation, budget formulation), organizational processes (authority and influence, client management, conflict resolution, motivation, and cultural maintenance), and measurement and reporting processes (financial and programmatic). Each process typically spans several functional units. Senior management must consider how to improve both the functioning of each CFP, as well as its "fit" with the other nine. The result can be greater clinical integration, improved cost management, and more coordinated care for enrollees.
NASA Technical Reports Server (NTRS)
Mandy, Christophe P.; Sakamoto, Hiraku; Saenz-Otero, Alvar; Miller, David W.
2007-01-01
The MIT's Space Systems Laboratory developed the Synchronized Position Hold Engage and Reorient Experimental Satellites (SPHERES) as a risk-tolerant spaceborne facility to develop and mature control, estimation, and autonomy algorithms for distributed satellite systems for applications such as satellite formation flight. Tests performed study interferometric mission-type formation flight maneuvers in deep space. These tests consist of having the satellites trace a coordinated trajectory under tight control that would allow simulated apertures to constructively interfere observed light and measure the resulting increase in angular resolution. This paper focuses on formation initialization (establishment of a formation using limited field of view relative sensors), formation coordination (synchronization of the different satellite s motion) and fuel-balancing among the different satellites.
Rong, Wei; Li, Waiming; Pang, Mankit; Hu, Junyan; Wei, Xijun; Yang, Bibo; Wai, Honwah; Zheng, Xiaoxiang; Hu, Xiaoling
2017-04-26
It is a challenge to reduce the muscular discoordination in the paretic upper limb after stroke in the traditional rehabilitation programs. In this study, a neuromuscular electrical stimulation (NMES) and robot hybrid system was developed for multi-joint coordinated upper limb physical training. The system could assist the elbow, wrist and fingers to conduct arm reaching out, hand opening/grasping and arm withdrawing by tracking an indicative moving cursor on the screen of a computer, with the support from the joint motors and electrical stimulations on target muscles, under the voluntary intention control by electromyography (EMG). Subjects with chronic stroke (n = 11) were recruited for the investigation on the assistive capability of the NMES-robot and the evaluation of the rehabilitation effectiveness through a 20-session device assisted upper limb training. In the evaluation, the movement accuracy measured by the root mean squared error (RMSE) during the tracking was significantly improved with the support from both the robot and NMES, in comparison with those without the assistance from the system (P < 0.05). The intra-joint and inter-joint muscular co-contractions measured by EMG were significantly released when the NMES was applied to the agonist muscles in the different phases of the limb motion (P < 0.05). After the physical training, significant improvements (P < 0.05) were captured by the clinical scores, i.e., Modified Ashworth Score (MAS, the elbow and the wrist), Fugl-Meyer Assessment (FMA), Action Research Arm Test (ARAT), and Wolf Motor Function Test (WMFT). The EMG-driven NMES-robotic system could improve the muscular coordination at the elbow, wrist and fingers. ClinicalTrials.gov. NCT02117089 ; date of registration: April 10, 2014.
EuCARD2: enhanced accelerator research and development in Europe
NASA Astrophysics Data System (ADS)
Romaniuk, Ryszard S.
2013-10-01
Accelerator science and technology is one of a key enablers of the developments in the particle physic, photon physics and also applications in medicine and industry. EuCARD2 is an European research project which will be realized during 2013-2017 inside the EC FP7 framework. The project concerns the development and coordination of European Accelerator Research and Development. The project is particularly important, to a number of domestic laboratories, due to some plans to build large accelerator infrastructure in Poland. Large accelerator infrastructure of fundamental and applied research character stimulates around it the development and industrial applications as well as biomedical of advanced accelerators, material research and engineering, cryo-technology, mechatronics, robotics, and in particular electronics - like networked measurement and control systems, sensors, computer systems, automation and control systems. The paper presents a digest of the European project EuCARD2 which is Enhanced European Coordination for Accelerator Research and Development. The paper presents a digest of the research results and assumptions in the domain of accelerator science and technology in Europe, shown during the final fourth annual meeting of the EuCARD - European Coordination of Accelerator R&D, and the kick-off meeting of the EuCARD2. There are debated a few basic groups of accelerator systems components like: measurement - control networks of large geometrical extent, multichannel systems for large amounts of metrological data acquisition, precision photonic networks of reference time, frequency and phase distribution, high field magnets, superconducting cavities, novel beam collimators, etc. The paper bases on the following materials: Internet and Intranet documents combined with EuCARD2, Description of Work FP7 EuCARD-2 DoW-312453, 2013-02-13, and discussions and preparatory materials worked on by Eucard-2 initiators.
High accuracy step gauge interferometer
NASA Astrophysics Data System (ADS)
Byman, V.; Jaakkola, T.; Palosuo, I.; Lassila, A.
2018-05-01
Step gauges are convenient transfer standards for the calibration of coordinate measuring machines. A novel interferometer for step gauge calibrations implemented at VTT MIKES is described. The four-pass interferometer follows Abbe’s principle and measures the position of the inductive probe attached to a measuring head. The measuring head of the instrument is connected to a balanced boom above the carriage by a piezo translation stage. A key part of the measuring head is an invar structure on which the inductive probe and the corner cubes of the measuring arm of the interferometer are attached. The invar structure can be elevated so that the probe is raised without breaking the laser beam. During probing, the bending of the probe and the interferometer readings are recorded and the measurement face position is extrapolated to zero force. The measurement process is fully automated and the face positions of the steps can be measured up to a length of 2 m. Ambient conditions are measured continuously and the refractive index of air is compensated for. Before measurements the step gauge is aligned with an integrated 2D coordinate measuring system. The expanded uncertainty of step gauge calibration is U=\\sqrt{{{(64 nm)}2}+{{(88× {{10}-9}L)}2}} .
ERIC Educational Resources Information Center
Laurent, Heidemarie K.; Ablow, Jennifer C.; Measelle, Jeffrey
2012-01-01
This study investigated continuity and stability of hypothalamic-pituitary-adrenal (HPA) and sympathetic nervous system (SNS) response measures in mother-infant dyads across 2 different types of social stress sessions. Synchrony of response trajectories across systems (SNS-HPA coordination) and partners (mother-infant attunement) was addressed, as…
JPDO Portfolio Analysis of NextGen
2009-09-01
runways. C. Metrics The JPDO Interagency Portfolio & Systems Analysis ( IPSA ) division continues to coordinate, develop, and refine the metrics and...targets associated with the NextGen initiatives with the partner agencies & stakeholder communities. IPSA has formulated a set of top-level metrics as...metrics are calculated from system performance measures that constitute outputs of the American Institute of Aeronautics and Astronautics 8 IPSA
Boelen, Charles
2018-01-01
As the purpose of medical education is to produce graduates able to most effectively address people's health concerns, there is general agreement that coordination with the health care system is essential. For too long, coordination has been dealt with in a subjective manner with only few landmarks to ensure objective and measurable achievements. Over the last 30 years, since the Edinburgh Declaration on medical education, progress has been made, namely with the concept of social accountability. The social accountability approach provides a way to plan, deliver and assess medical education with the explicit aim to contribute to effective, equitable and sustainable health system development. It is based on a system-wide scope exploring issues from identification of people's and society's health needs to verification of the effects of medical education in meeting those needs. A wide international consultation among medical education leaders led to the adoption of the Global Consensus on Social Accountability of Medical Schools. Benchmarks of social accountability are in the process of being conceived and tested, enabling medical schools to steer medical education in a more purposeful way in relation to determinants of health. A sample of schools using the social accountability approach claims to have had a positive influence on health care system performance and people's health status. Improved coordination of medical education and other key stakeholders in the health system is an important challenge for medical schools as well as for countries confronted with an urgent need for optimal use of their health workforce. There is growing interest worldwide in defining policies and strategies and supporting experiences in this regard. © 2017 John Wiley & Sons Ltd and The Association for the Study of Medical Education.
Optical technologies for space sensor
NASA Astrophysics Data System (ADS)
Wang, Hu; Liu, Jie; Xue, Yaoke; Liu, Yang; Liu, Meiying; Wang, Lingguang; Yang, Shaodong; Lin, Shangmin; Chen, Su; Luo, Jianjun
2015-10-01
Space sensors are used in navigation sensor fields. The sun, the earth, the moon and other planets are used as frame of reference to obtain stellar position coordinates, and then to control the attitude of an aircraft. Being the "eyes" of the space sensors, Optical sensor system makes images of the infinite far stars and other celestial bodies. It directly affects measurement accuracy of the space sensor, indirectly affecting the data updating rate. Star sensor technology is the pilot for Space sensors. At present more and more attention is paid on all-day star sensor technology. By day and night measurements of the stars, the aircraft's attitude in the inertial coordinate system can be provided. Facing the requirements of ultra-high-precision, large field of view, wide spectral range, long life and high reliability, multi-functional optical system, we integration, integration optical sensors will be future space technology trends. In the meantime, optical technologies for space-sensitive research leads to the development of ultra-precision optical processing, optical and precision test machine alignment technology. It also promotes the development of long-life optical materials and applications. We have achieved such absolute distortion better than ±1um, Space life of at least 15years of space-sensitive optical system.
Algorithms used in the Airborne Lidar Processing System (ALPS)
Nagle, David B.; Wright, C. Wayne
2016-05-23
The Airborne Lidar Processing System (ALPS) analyzes Experimental Advanced Airborne Research Lidar (EAARL) data—digitized laser-return waveforms, position, and attitude data—to derive point clouds of target surfaces. A full-waveform airborne lidar system, the EAARL seamlessly and simultaneously collects mixed environment data, including submerged, sub-aerial bare earth, and vegetation-covered topographies.ALPS uses three waveform target-detection algorithms to determine target positions within a given waveform: centroid analysis, leading edge detection, and bottom detection using water-column backscatter modeling. The centroid analysis algorithm detects opaque hard surfaces. The leading edge algorithm detects topography beneath vegetation and shallow, submerged topography. The bottom detection algorithm uses water-column backscatter modeling for deeper submerged topography in turbid water.The report describes slant range calculations and explains how ALPS uses laser range and orientation measurements to project measurement points into the Universal Transverse Mercator coordinate system. Parameters used for coordinate transformations in ALPS are described, as are Interactive Data Language-based methods for gridding EAARL point cloud data to derive digital elevation models. Noise reduction in point clouds through use of a random consensus filter is explained, and detailed pseudocode, mathematical equations, and Yorick source code accompany the report.
ERIC Educational Resources Information Center
Habre, Samer
2017-01-01
Covariational reasoning has been the focus of many studies but only a few looked into this reasoning in the polar coordinate system. In fact, research on student's familiarity with polar coordinates and graphing in the polar coordinate system is scarce. This paper examines the challenges that students face when plotting polar curves using the…
Coordinate references for the indoor/outdoor seamless positioning
NASA Astrophysics Data System (ADS)
Ruan, Ling; Zhang, Ling; Long, Yi; Cheng, Fei
2018-05-01
Indoor positioning technologies are being developed rapidly, and seamless positioning which connected indoor and outdoor space is a new trend. The indoor and outdoor positioning are not applying the same coordinate system and different indoor positioning scenes uses different indoor local coordinate reference systems. A specific and unified coordinate reference frame is needed as the space basis and premise in seamless positioning application. Trajectory analysis of indoor and outdoor integration also requires a uniform coordinate reference. However, the coordinate reference frame in seamless positioning which can applied to various complex scenarios is lacking of research for a long time. In this paper, we proposed a universal coordinate reference frame in indoor/outdoor seamless positioning. The research focus on analysis and classify the indoor positioning scenes and put forward the coordinate reference system establishment and coordinate transformation methods in each scene. And, through some experiments, the calibration method feasibility was verified.
An examination of an adapter method for measuring the vibration transmitted to the human arms.
Xu, Xueyan S; Dong, Ren G; Welcome, Daniel E; Warren, Christopher; McDowell, Thomas W
2015-09-01
The objective of this study is to evaluate an adapter method for measuring the vibration on the human arms. Four instrumented adapters with different weights were used to measure the vibration transmitted to the wrist, forearm, and upper arm of each subject. Each adapter was attached at each location on the subjects using an elastic cloth wrap. Two laser vibrometers were also used to measure the transmitted vibration at each location to evaluate the validity of the adapter method. The apparent mass at the palm of the hand along the forearm direction was also measured to enhance the evaluation. This study found that the adapter and laser-measured transmissibility spectra were comparable with some systematic differences. While increasing the adapter mass reduced the resonant frequency at the measurement location, increasing the tightness of the adapter attachment increased the resonant frequency. However, the use of lightweight (≤15 g) adapters under medium attachment tightness did not change the basic trends of the transmissibility spectrum. The resonant features observed in the transmissibility spectra were also correlated with those observed in the apparent mass spectra. Because the local coordinate systems of the adapters may be significantly misaligned relative to the global coordinates of the vibration test systems, large errors were observed for the adapter-measured transmissibility in some individual orthogonal directions. This study, however, also demonstrated that the misalignment issue can be resolved by either using the total vibration transmissibility or by measuring the misalignment angles to correct the errors. Therefore, the adapter method is acceptable for understanding the basic characteristics of the vibration transmission in the human arms, and the adapter-measured data are acceptable for approximately modeling the system.
An examination of an adapter method for measuring the vibration transmitted to the human arms
Xu, Xueyan S.; Dong, Ren G.; Welcome, Daniel E.; Warren, Christopher; McDowell, Thomas W.
2016-01-01
The objective of this study is to evaluate an adapter method for measuring the vibration on the human arms. Four instrumented adapters with different weights were used to measure the vibration transmitted to the wrist, forearm, and upper arm of each subject. Each adapter was attached at each location on the subjects using an elastic cloth wrap. Two laser vibrometers were also used to measure the transmitted vibration at each location to evaluate the validity of the adapter method. The apparent mass at the palm of the hand along the forearm direction was also measured to enhance the evaluation. This study found that the adapter and laser-measured transmissibility spectra were comparable with some systematic differences. While increasing the adapter mass reduced the resonant frequency at the measurement location, increasing the tightness of the adapter attachment increased the resonant frequency. However, the use of lightweight (≤15 g) adapters under medium attachment tightness did not change the basic trends of the transmissibility spectrum. The resonant features observed in the transmissibility spectra were also correlated with those observed in the apparent mass spectra. Because the local coordinate systems of the adapters may be significantly misaligned relative to the global coordinates of the vibration test systems, large errors were observed for the adapter-measured transmissibility in some individual orthogonal directions. This study, however, also demonstrated that the misalignment issue can be resolved by either using the total vibration transmissibility or by measuring the misalignment angles to correct the errors. Therefore, the adapter method is acceptable for understanding the basic characteristics of the vibration transmission in the human arms, and the adapter-measured data are acceptable for approximately modeling the system. PMID:26834309
Thayer, Edward C.; Olson, Maynard V.; Karp, Richard M.
1999-01-01
Genetic and physical maps display the relative positions of objects or markers occurring within a target DNA molecule. In constructing maps, the primary objective is to determine the ordering of these objects. A further objective is to assign a coordinate to each object, indicating its distance from a reference end of the target molecule. This paper describes a computational method and a body of software for assigning coordinates to map objects, given a solution or partial solution to the ordering problem. We describe our method in the context of multiple–complete–digest (MCD) mapping, but it should be applicable to a variety of other mapping problems. Because of errors in the data or insufficient clone coverage to uniquely identify the true ordering of the map objects, a partial ordering is typically the best one can hope for. Once a partial ordering has been established, one often seeks to overlay a metric along the map to assess the distances between the map objects. This problem often proves intractable because of data errors such as erroneous local length measurements (e.g., large clone lengths on low-resolution physical maps). We present a solution to the coordinate assignment problem for MCD restriction-fragment mapping, in which a coordinated set of single-enzyme restriction maps are simultaneously constructed. We show that the coordinate assignment problem can be expressed as the solution of a system of linear constraints. If the linear system is free of inconsistencies, it can be solved using the standard Bellman–Ford algorithm. In the more typical case where the system is inconsistent, our program perturbs it to find a new consistent system of linear constraints, close to those of the given inconsistent system, using a modified Bellman–Ford algorithm. Examples are provided of simple map inconsistencies and the methods by which our program detects candidate data errors and directs the user to potential suspect regions of the map. PMID:9927487
Chaotic coordinates for the Large Helical Device
NASA Astrophysics Data System (ADS)
Hudson, Stuart; Suzuki, Yasuhiro
2014-10-01
The study of dynamical systems is facilitated by a coordinate framework with coordinate surfaces that coincide with invariant structures of the dynamical flow. For axisymmetric systems, a continuous family of invariant surfaces is guaranteed and straight-fieldline coordinates may be constructed. For non-integrable systems, e.g. stellarators, perturbed tokamaks, this continuous family is broken. Nevertheless, coordinates can still be constructed that simplify the description of the dynamics. The Poincare-Birkhoff theorem, the Aubry-Mather theorem, and the KAM theorem show that there are important structures that are invariant under the perturbed dynamics; namely the periodic orbits, the cantori, and the irrational flux surfaces. Coordinates adapted to these invariant sets, which we call chaotic coordinates, provide substantial advantages. The regular motion becomes straight, and the irregular motion is bounded by, and dissected by, coordinate surfaces that coincide with surfaces of locally-minimal magnetic-fieldline flux. The chaotic edge of the magnetic field, as calculated by HINT2 code, in the Large Helical Device (LHD) is examined, and a coordinate system is constructed so that the flux surfaces are ``straight'' and the islands become ``square.''
Kotte, Amelia; Hill, Kaitlin A; Mah, Albert C; Korathu-Larson, Priya A; Au, Janelle R; Izmirian, Sonia; Keir, Scott S; Nakamura, Brad J; Higa-McMillan, Charmaine K
2016-11-01
This study examines implementation facilitators and barriers of a statewide roll-out of a measurement feedback system (MFS) in a youth public mental health system. 76 % of all state care coordinators (N = 47) completed interviews, which were coded via content analysis until saturation. Facilitators (e.g., recognition of the MFS's clinical utility) and barriers (e.g., MFS's reliability and validity) emerged paralleling the Exploration, Adoption/Preparation, Implementation, and Sustainment framework outlined by Aarons et al. (Adm Policy Mental Health Mental Health Serv Res, 38:4-23, 2011). Sustainment efforts may leverage innovation fit, individual adopter, and system related facilitators.
Celestial Navigation with the Stereographic Projection
ERIC Educational Resources Information Center
Hutton, D. R.
1977-01-01
Presented is an exercise in the ability to navigate by the stars. It applies difficult concepts of positional astronomy concerning coordinate systems and time. Stereographic projection is utilized because it allows rapid completion of calculations and measurements and keeps the concepts clear to the students. (MA)
Impact of Math Snacks Games on Students' Conceptual Understanding
ERIC Educational Resources Information Center
Winburg, Karin; Chamberlain, Barbara; Valdez, Alfred; Trujillo, Karen; Stanford, Theodore B.
2016-01-01
This "Math Snacks" intervention measured 741 fifth grade students' gains in conceptual understanding of core math concepts after game-based learning activities. Teachers integrated four "Math Snacks" games and related activities into instruction on ratios, coordinate plane, number systems, fractions and decimals. Using a…
Single camera photogrammetry system for EEG electrode identification and localization.
Baysal, Uğur; Sengül, Gökhan
2010-04-01
In this study, photogrammetric coordinate measurement and color-based identification of EEG electrode positions on the human head are simultaneously implemented. A rotating, 2MP digital camera about 20 cm above the subject's head is used and the images are acquired at predefined stop points separated azimuthally at equal angular displacements. In order to realize full automation, the electrodes have been labeled by colored circular markers and an electrode recognition algorithm has been developed. The proposed method has been tested by using a plastic head phantom carrying 25 electrode markers. Electrode locations have been determined while incorporating three different methods: (i) the proposed photogrammetric method, (ii) conventional 3D radiofrequency (RF) digitizer, and (iii) coordinate measurement machine having about 6.5 mum accuracy. It is found that the proposed system automatically identifies electrodes and localizes them with a maximum error of 0.77 mm. It is suggested that this method may be used in EEG source localization applications in the human brain.
de Vries, W H K; Veeger, H E J; Cutti, A G; Baten, C; van der Helm, F C T
2010-07-20
Inertial Magnetic Measurement Systems (IMMS) are becoming increasingly popular by allowing for measurements outside the motion laboratory. The latest models enable long term, accurate measurement of segment motion in terms of joint angles, if initial segment orientations can accurately be determined. The standard procedure for definition of segmental orientation is based on the measurement of positions of bony landmarks (BLM). However, IMMS do not deliver position information, so an alternative method to establish IMMS based, anatomically understandable segment orientations is proposed. For five subjects, IMMS recordings were collected in a standard anatomical position for definition of static axes, and during a series of standardized motions for the estimation of kinematic axes of rotation. For all axes, the intra- and inter-individual dispersion was estimated. Subsequently, local coordinate systems (LCS) were constructed on the basis of the combination of IMMS axes with the lowest dispersion and compared with BLM based LCS. The repeatability of the method appeared to be high; for every segment at least two axes could be determined with a dispersion of at most 3.8 degrees. Comparison of IMMS based with BLM based LCS yielded compatible results for the thorax, but less compatible results for the humerus, forearm and hand, where differences in orientation rose to 17.2 degrees. Although different from the 'gold standard' BLM based LCS, IMMS based LCS can be constructed repeatable, enabling the estimation of segment orientations outside the laboratory. A procedure for the definition of local reference frames using IMMS is proposed. 2010 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Noe, Frank
To efficiently simulate and generate understanding from simulations of complex macromolecular systems, the concept of slow collective coordinates or reaction coordinates is of fundamental importance. Here we will introduce variational approaches to approximate the slow coordinates and the reaction coordinates between selected end-states given MD simulations of the macromolecular system and a (possibly large) basis set of candidate coordinates. We will then discuss how to select physically intuitive order paremeters that are good surrogates of this variationally optimal result. These result can be used in order to construct Markov state models or other models of the stationary and kinetics properties, in order to parametrize low-dimensional / coarse-grained model of the dynamics. Deutsche Forschungsgemeinschaft, European Research Council.
Rare earth niobate coordination polymers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muniz, Collin N.; Patel, Hiral; Fast, Dylan B.
Rare-earth (RE) coordination polymers are infinitely tailorable to yield luminescent materials for various applications. In this paper we described the synthesis of a heterometallic rare-earth coordination compound ((CH 3) 2SO) 3(RE)NbO(C 2O 4) 3 ((CH 3) 2SO) = dimethylsulfoxide, DMSO, (C 2O 2 = oxalate), (RE=La, Ce, Pr, Nd, Sm, Eu, Gd, Tb). The structure was obtained from single crystal X-ray diffraction of the La analogue. The Nb =O and DMSO terminal-bonding character guides assembly of an open framework structure with noncentrosymmetric RE-coordination geometry, and large spacing between the RE centers. A second structure was observed by PXRD for themore » smaller rare earths (Dy, Ho, Er, Yb); this structure has not yet been determined. The materials were further characterized using FTIR, and photoluminescence measurements. Characteristic excitation and emission transitions were observed for RE = Nd, Sm, Eu, and Tb. Quantum yield (QY) measurements were performed by exciting Eu and Tb analoges at 394 nm (QY 66%) and 464 nm (QY 71%) for Eu; and 370 nm (QY=40%) for Tb. Finally, we attribute the high QY and bright luminescence to two main structure-function properties of the system; namely the absence of water in the structure, and absence of concentration quenching.« less
Rare earth niobate coordination polymers
Muniz, Collin N.; Patel, Hiral; Fast, Dylan B.; ...
2018-01-03
Rare-earth (RE) coordination polymers are infinitely tailorable to yield luminescent materials for various applications. In this paper we described the synthesis of a heterometallic rare-earth coordination compound ((CH 3) 2SO) 3(RE)NbO(C 2O 4) 3 ((CH 3) 2SO) = dimethylsulfoxide, DMSO, (C 2O 2 = oxalate), (RE=La, Ce, Pr, Nd, Sm, Eu, Gd, Tb). The structure was obtained from single crystal X-ray diffraction of the La analogue. The Nb =O and DMSO terminal-bonding character guides assembly of an open framework structure with noncentrosymmetric RE-coordination geometry, and large spacing between the RE centers. A second structure was observed by PXRD for themore » smaller rare earths (Dy, Ho, Er, Yb); this structure has not yet been determined. The materials were further characterized using FTIR, and photoluminescence measurements. Characteristic excitation and emission transitions were observed for RE = Nd, Sm, Eu, and Tb. Quantum yield (QY) measurements were performed by exciting Eu and Tb analoges at 394 nm (QY 66%) and 464 nm (QY 71%) for Eu; and 370 nm (QY=40%) for Tb. Finally, we attribute the high QY and bright luminescence to two main structure-function properties of the system; namely the absence of water in the structure, and absence of concentration quenching.« less
Teamwork methods for accountable care: relational coordination and TeamSTEPPS®.
Gittell, Jody Hoffer; Beswick, Joanne; Goldmann, Don; Wallack, Stanley S
2015-01-01
To deliver greater value in the accountable care context, the Institute of Medicine argues for a culture of teamwork at multiple levels--across professional and organizational siloes and with patients and their families and communities. The logic of performance improvement is that data are needed to target interventions and to assess their impact. We argue that efforts to build teamwork will benefit from teamwork measures that provide diagnostic information regarding the current state and teamwork interventions that can respond to the opportunities identified in the current state. We identify teamwork measures and teamwork interventions that are validated and that can work across multiple levels of teamwork. We propose specific ways to combine them for optimal effectiveness. We review measures of teamwork documented by Valentine, Nembhard, and Edmondson and select those that they identified as satisfying the four criteria for psychometric validation and as being unbounded and therefore able to measure teamwork across multiple levels. We then consider teamwork interventions that are widely used in the U.S. health care context, are well validated based on their association with outcomes, and are capable of working at multiple levels of teamwork. We select the top candidate in each category and propose ways to combine them for optimal effectiveness. We find relational coordination is a validated multilevel teamwork measure and TeamSTEPPS® is a validated multilevel teamwork intervention and propose specific ways for the relational coordination measure to enhance the TeamSTEPPS intervention. Health care systems and change agents seeking to respond to the challenges of accountable care can use TeamSTEPPS as a validated multilevel teamwork intervention methodology, enhanced by relational coordination as a validated multilevel teamwork measure with diagnostic capacity to pinpoint opportunities for improving teamwork along specific dimensions (e.g., shared knowledge, timely communication) and in specific role relationships (e.g., nurse/medical assistant, emergency unit/medical unit, primary care/specialty care).
A versatile localization system for microscopic multiparametric analysis of cells.
Thaw, H H; Rundquist, I; Johansson, U; Svensson, I; Collins, V P
1983-03-01
A new, simple and relatively inexpensive electronic digital position readout (DPRO) system which can be applied to the rapid localization and recovery of microscopic material is described. It is based upon a commercially available digital position readout system which is routinely utilized by industry for small machine tools and measuring equipment. This has been mounted onto the stage of various microscopic instrumentation to provide X and Y coordinates relative to an arbitrary reference point. The integration of small computers interfaced to scanning interferometric, microdensitometric and fluorescence microscopes were used to demonstrate the reliability, versatility and ease of application of this system to problems of multiparametric measurements and analysis of cultured cells. The system may be expanded and applied to clinical material to obtain automatized, multiparametric measurements of cells in haematology and clinical cytology.
NASA Astrophysics Data System (ADS)
Li, Peng; Chong, Wenyan; Ma, Yongjun
2017-10-01
In order to avoid shortcomings of low efficiency and restricted measuring range exsited in traditional 3D on-line contact measurement method for workpiece size, the development of a novel 3D contact measurement system is introduced, which is designed for intelligent manufacturing based on stereo vision. The developed contact measurement system is characterized with an intergarted use of a handy probe, a binocular stereo vision system, and advanced measurement software.The handy probe consists of six track markers, a touch probe and the associated elcetronics. In the process of contact measurement, the hand probe can be located by the use of the stereo vision system and track markers, and 3D coordinates of a space point on the workpiece can be mearsured by calculating the tip position of a touch probe. With the flexibility of the hand probe, the orientation, range, density of the 3D contact measurenent can be adptable to different needs. Applications of the developed contact measurement system to high-precision measurement and rapid surface digitization are experimentally demonstrated.
Accuracy and Availability of Egnos - Results of Observations
NASA Astrophysics Data System (ADS)
Felski, Andrzej; Nowak, Aleksander; Woźniak, Tomasz
2011-01-01
According to SBAS concept the user should receive timely the correct information about the system integrity and corrections to the pseudoranges measurements, which leads to better accuracy of coordinates. In theory the whole system is permanently monitored by RIMS stations, so it is impossible to deliver the faulty information to the user. The quality of the system is guaranteed inside the border of the system coverage however in the east part of Poland lower accuracy and availability of the system is still observed. This was the impulse to start an observation and analysis of real accuracy and availability of EGNOS service in the context of support air-operations in local airports and as the supplementation in hydrographic operations on the Polish Exclusive Zone. A registration has been conducted on three PANSA stations situated on airports in Warsaw, Krakow and Rzeszow and on PNA station in Gdynia. Measurements on PANSA stations have been completed permanently during each whole month up to end of September 2011. These stations are established on Septentrio PolaRx2e receivers and have been engaged into EGNOS Data Collection Network performed by EUROCONTROL. The advantage of these registrations is the uniformity of receivers. Apart from these registrations additional measurements in Gdynia have been provided with different receivers, mainly dedicated sea-navigation: CSI Wireless 1, NOVATEL OEMV, Sperry Navistar, Crescent V-100 and R110 as well as Magellan FX420. The main object of analyses was the accuracy and availability of EGNOS service in each point and for different receivers. Accuracy has been analyzed separately for each coordinate. Finally the temporarily and spatial correlations of coordinates, its availability and accuracy has been investigated. The findings prove that present accuracy of EGNOS service is about 1,5m (95%), but availability of the service is controversial. The accuracy of present EGNOS service meets the parameters of APV I and even APV II requirements, as well as any maritime and hydrography needs. However introducing this service into the practice demands better availability, because the gaps in receiving the proper information from the system appear too often and are too long at the moment. Additionally it was noticed very random character of availability and no correlation of this parameter in the different point of observations. In spite the correct EGNOS work the accuracy of the coordinates is not predictable in the local conditions. So in authors' opinion Local Airport Monitoring should be deployed if EGNOS would have to serve to the local airport service.
Hand-Eye Calibration of Robonaut
NASA Technical Reports Server (NTRS)
Nickels, Kevin; Huber, Eric
2004-01-01
NASA's Human Space Flight program depends heavily on Extra-Vehicular Activities (EVA's) performed by human astronauts. EVA is a high risk environment that requires extensive training and ground support. In collaboration with the Defense Advanced Research Projects Agency (DARPA), NASA is conducting a ground development project to produce a robotic astronaut's assistant, called Robonaut, that could help reduce human EVA time and workload. The project described in this paper designed and implemented a hand-eye calibration scheme for Robonaut, Unit A. The intent of this calibration scheme is to improve hand-eye coordination of the robot. The basic approach is to use kinematic and stereo vision measurements, namely the joint angles self-reported by the right arm and 3-D positions of a calibration fixture as measured by vision, to estimate the transformation from Robonaut's base coordinate system to its hand coordinate system and to its vision coordinate system. Two methods of gathering data sets have been developed, along with software to support each. In the first, the system observes the robotic arm and neck angles as the robot is operated under external control, and measures the 3-D position of a calibration fixture using Robonaut's stereo cameras, and logs these data. In the second, the system drives the arm and neck through a set of pre-recorded configurations, and data are again logged. Two variants of the calibration scheme have been developed. The full calibration scheme is a batch procedure that estimates all relevant kinematic parameters of the arm and neck of the robot The daily calibration scheme estimates only joint offsets for each rotational joint on the arm and neck, which are assumed to change from day to day. The schemes have been designed to be automatic and easy to use so that the robot can be fully recalibrated when needed such as after repair, upgrade, etc, and can be partially recalibrated after each power cycle. The scheme has been implemented on Robonaut Unit A and has been shown to reduce mismatch between kinematically derived positions and visually derived positions from a mean of 13.75cm using the previous calibration to means of 1.85cm using a full calibration and 2.02cm using a suboptimal but faster daily calibration. This improved calibration has already enabled the robot to more accurately reach for and grasp objects that it sees within its workspace. The system has been used to support an autonomous wrench-grasping experiment and significantly improved the workspace positioning of the hand based on visually derived wrench position. estimates.
Results of the NIST National Ball Plate Round Robin.
Caskey, G W; Phillips, S D; Borchardt, B R
1997-01-01
This report examines the results of the ball plate round robin administered by NIST. The round robin was part of an effort to assess the current state of industry practices for measurements made using coordinate measuring machines. Measurements of a two-dimensional ball plate (240 mm by 240 mm) on 41 coordinate measuring machines were collected and analyzed. Typically, the deviations of the reported X and Y coordinates from the calibrated values were within ± 5 μm, with some coordinate deviations exceeding 20.0 μm. One of the most significant observations from these data was that over 75 % of the participants failed to correctly estimate their measurement error on one or more of the ball plate spheres.
On the Scene: Developing a Nurse Care Coordinator Role at City of Hope.
Johnson, Shirley A; Giesie, Pamela D; Ireland, Anne M; Rice, Robert David; Thomson, Brenda K
2016-01-01
We describe the development of an oncology solid tumor disease-focused care coordination model. Consistent with our strategic plan to provide patient- and family-centered care and to organize care around disease management teams, we developed the role of nurse care coordinator as an integral team member in our care delivery model. Managing a defined high-risk patient population across the care trajectory, these nurses provide stable points of contact and continuity for patients and families as they navigate the complex treatments and systems required to deliver cancer care. We describe role delineation and staffing models; role clarity between the role of the nurse care coordinator and the case manager; core curriculum development; the use of workflow management tools to support the touch points of the patient and members of the care team; and the incorporation of electronic medical records and data streams to inform the care delivery model. We identify measures that we will use to evaluate the success of our program.
The forward modelling and analysis of magnetic field on the East Asia area using tesseroids
NASA Astrophysics Data System (ADS)
Chen, Z.; Meng, X.; Xu, G.
2017-12-01
As the progress of airborne and satellite magnetic survey, high-resolution magnetic data could be measured at different scale. In order to test and improve the accuracy of the existing crustal model, the forward modeling method is usually used to simulate the magnetic field of the lithosphere. Traditional models to forward modelling the magnetic field are based on the Cartesian coordinate system, and are always used to calculate the magnetic field of the local and small area. However, the Cartesian coordinate system is not an ideal choice for calculating the magnetic field of the global or continental area at the height of the satellite and Earth's curvature cannot be ignored in this situation. The spherical element (called tesseroids) can be used as a model element in the spherical coordinate system to solve this problem. On the basis of studying the principle of this forward method, we focus the selection of data source and the mechanism of adaptive integration. Then we calculate the magnetic anomaly data of East Asia area based on the model Crust1.0. The results presented the crustal susceptibility distribution, which was well consistent with the basic tectonic features in the study area.
Geary, David C.; Hoard, Mary K.; Nugent, Lara; Rouder, Jeffrey N.
2015-01-01
The relation between performance on measures of algebraic cognition and acuity of the approximate number system (ANS) and memory for addition facts was assessed for 171 (92 girls) 9th graders, controlling parental education, sex, reading achievement, speed of numeral processing, fluency of symbolic number processing, intelligence, and the central executive component of working memory. The algebraic tasks assessed accuracy in placing x,y pairs in the coordinate plane, speed and accuracy of expression evaluation, and schema memory for algebra equations. ANS acuity was related to accuracy of placements in the coordinate plane and expression evaluation, but not schema memory. Frequency of fact-retrieval errors was related to schema memory but not coordinate plane or expression evaluation accuracy. The results suggest the ANS may contribute to or is influenced by spatial-numerical and numerical only quantity judgments in algebraic contexts, whereas difficulties in committing addition facts to long-term memory may presage slow formation of memories for the basic structure of algebra equations. More generally, the results suggest different brain and cognitive systems are engaged during the learning of different components of algebraic competence, controlling demographic and domain general abilities. PMID:26255604
Develop Direct Geo-referencing System Based on Open Source Software and Hardware Platform
NASA Astrophysics Data System (ADS)
Liu, H. S.; Liao, H. M.
2015-08-01
Direct geo-referencing system uses the technology of remote sensing to quickly grasp images, GPS tracks, and camera position. These data allows the construction of large volumes of images with geographic coordinates. So that users can be measured directly on the images. In order to properly calculate positioning, all the sensor signals must be synchronized. Traditional aerial photography use Position and Orientation System (POS) to integrate image, coordinates and camera position. However, it is very expensive. And users could not use the result immediately because the position information does not embed into image. To considerations of economy and efficiency, this study aims to develop a direct geo-referencing system based on open source software and hardware platform. After using Arduino microcontroller board to integrate the signals, we then can calculate positioning with open source software OpenCV. In the end, we use open source panorama browser, panini, and integrate all these to open source GIS software, Quantum GIS. A wholesome collection of data - a data processing system could be constructed.
NASA Technical Reports Server (NTRS)
Winn, C. B.; Huston, W.
1981-01-01
A geostationary reference satellite (REFSAT) that broadcasts every four seconds updated GPS satellite coordinates was developed. This procedure reduces the complexity of the GPS receiver. The economic and performance payoffs associated with replacing maritime stripborne navigation systems with NAVSTAR was quantified and the use of NAVSTAR for measurements of ocean currents in the broad ocean areas of the world was evaluated.
A Virtual Blind Cane Using a Line Laser-Based Vision System and an Inertial Measurement Unit
Dang, Quoc Khanh; Chee, Youngjoon; Pham, Duy Duong; Suh, Young Soo
2016-01-01
A virtual blind cane system for indoor application, including a camera, a line laser and an inertial measurement unit (IMU), is proposed in this paper. Working as a blind cane, the proposed system helps a blind person find the type of obstacle and the distance to it. The distance from the user to the obstacle is estimated by extracting the laser coordinate points on the obstacle, as well as tracking the system pointing angle. The paper provides a simple method to classify the obstacle’s type by analyzing the laser intersection histogram. Real experimental results are presented to show the validity and accuracy of the proposed system. PMID:26771618
Deblurring for spatial and temporal varying motion with optical computing
NASA Astrophysics Data System (ADS)
Xiao, Xiao; Xue, Dongfeng; Hui, Zhao
2016-05-01
A way to estimate and remove spatially and temporally varying motion blur is proposed, which is based on an optical computing system. The translation and rotation motion can be independently estimated from the joint transform correlator (JTC) system without iterative optimization. The inspiration comes from the fact that the JTC system is immune to rotation motion in a Cartesian coordinate system. The work scheme of the JTC system is designed to keep switching between the Cartesian coordinate system and polar coordinate system in different time intervals with the ping-pang handover. In the ping interval, the JTC system works in the Cartesian coordinate system to obtain a translation motion vector with optical computing speed. In the pang interval, the JTC system works in the polar coordinate system. The rotation motion is transformed to the translation motion through coordinate transformation. Then the rotation motion vector can also be obtained from JTC instantaneously. To deal with continuous spatially variant motion blur, submotion vectors based on the projective motion path blur model are proposed. The submotion vectors model is more effective and accurate at modeling spatially variant motion blur than conventional methods. The simulation and real experiment results demonstrate its overall effectiveness.
NASA Technical Reports Server (NTRS)
Kumar, D.
1980-01-01
The computer program COORDC generates a body fitted curvilinear coordinate system for corner geometry with or without corner fillets. It is assumed that at any given xi, x remains constant; consequently the only variation is in y and z. It is also assumed that for all xi's in the physical plane the coordinate system in y-z plane is similar. This enables solution of coordinate system for one particular xi = 1 (x for xi = 1 is arbitrarily chosen to be 0.0) and the solution for all other xi plane can be easily specified once the coordinates in the physical plane on the line 1 or = to xi or = to IMAX, eta = 1, zeta = 1 are specified.
Implementation and validation of an implant-based coordinate system for RSA migration calculation.
Laende, Elise K; Deluzio, Kevin J; Hennigar, Allan W; Dunbar, Michael J
2009-10-16
An in vitro radiostereometric analysis (RSA) phantom study of a total knee replacement was carried out to evaluate the effect of implementing two new modifications to the conventional RSA procedure: (i) adding a landmark of the tibial component as an implant marker and (ii) defining an implant-based coordinate system constructed from implant landmarks for the calculation of migration results. The motivation for these two modifications were (i) to improve the representation of the implant by the markers by including the stem tip marker which increases the marker distribution (ii) to recover clinical RSA study cases with insufficient numbers of markers visible in the implant polyethylene and (iii) to eliminate errors in migration calculations due to misalignment of the anatomical axes with the RSA global coordinate system. The translational and rotational phantom studies showed no loss of accuracy with the two new measurement methods. The RSA system employing these methods has a precision of better than 0.05 mm for translations and 0.03 degrees for rotations, and an accuracy of 0.05 mm for translations and 0.15 degrees for rotations. These results indicate that the new methods to improve the interpretability, relevance, and standardization of the results do not compromise precision and accuracy, and are suitable for application to clinical data.
The display of spatial information and visually guided behavior
NASA Technical Reports Server (NTRS)
Bennett, C. Thomas
1991-01-01
The basic informational elements of spatial orientation are attitude and position within a coordinate system. The problem that faces aeronautical designers is that a pilot must deal with several coordinate systems, sometimes simultaneously. The display must depict unambiguously not only position and attitude, but also designate the relevant coordinate system. If this is not done accurately, spatial disorientation can occur. The different coordinate systems used in aeronautical tasks and the problems that occur in the display of spatial information are explained.
Educational Goals and Results, 1982-83.
ERIC Educational Resources Information Center
Wilson, Morris D.; Baldwin, Robert
As a function of Des Moines, Iowa's, planning and management system for improving educational services through coordinated, continuous planning and evaluation at all levels from superintendent to classroom teacher, this report measures the success of district administration and individual schools in achieving stated objectives for 1982-83. Five…
Wave Making Resistance Characteristics of Trimaran Hulls
2003-12-01
to increased emphasis on warships that can neutralize anti-access measures such as minefields, quiet diesel- electric submarines and swarms of small...package licensed by AMTEC Engineering. The reference coordinate system illustrated in Figure 3 and used by SWAN-2 must be selected such that the 0z
NASA Technical Reports Server (NTRS)
Rismantab-Sany, J.; Chang, B.; Shabana, A. A.
1989-01-01
A total Lagrangian finite element formulation for the deformable bodies in multibody mechanical systems that undergo finite relative rotations is developed. The deformable bodies are discretized using finite element methods. The shape functions that are used to describe the displacement field are required to include the rigid body modes that describe only large translational displacements. This does not impose any limitations on the technique because most commonly used shape functions satisfy this requirement. The configuration of an element is defined using four sets of coordinate systems: Body, Element, Intermediate element, Global. The body coordinate system serves as a unique standard for the assembly of the elements forming the deformable body. The element coordinate system is rigidly attached to the element and therefore it translates and rotates with the element. The intermediate element coordinate system, whose axes are initially parallel to the element axes, has an origin which is rigidly attached to the origin of the body coordinate system and is used to conveniently describe the configuration of the element in undeformed state with respect to the body coordinate system.
Pilot-model measurements of pilot responses in a lateral-directional control task
NASA Technical Reports Server (NTRS)
Adams, J. J.
1976-01-01
Pilot response during an aircraft bank-angle compensatory control task was measured by using an adaptive modeling technique. In the main control loop, which is the bank angle to aileron command loop, the pilot response was the same as that measured previously in single-input, single-output systems. The pilot used a rudder to aileron control coordination that canceled up to 80 percent of the vehicle yawing moment due to aileron deflection.
Intelligent multiagent coordination based on reinforcement hierarchical neuro-fuzzy models.
Mendoza, Leonardo Forero; Vellasco, Marley; Figueiredo, Karla
2014-12-01
This paper presents the research and development of two hybrid neuro-fuzzy models for the hierarchical coordination of multiple intelligent agents. The main objective of the models is to have multiple agents interact intelligently with each other in complex systems. We developed two new models of coordination for intelligent multiagent systems, which integrates the Reinforcement Learning Hierarchical Neuro-Fuzzy model with two proposed coordination mechanisms: the MultiAgent Reinforcement Learning Hierarchical Neuro-Fuzzy with a market-driven coordination mechanism (MA-RL-HNFP-MD) and the MultiAgent Reinforcement Learning Hierarchical Neuro-Fuzzy with graph coordination (MA-RL-HNFP-CG). In order to evaluate the proposed models and verify the contribution of the proposed coordination mechanisms, two multiagent benchmark applications were developed: the pursuit game and the robot soccer simulation. The results obtained demonstrated that the proposed coordination mechanisms greatly improve the performance of the multiagent system when compared with other strategies.
NASA Astrophysics Data System (ADS)
Guo, X.; Lange, R. A.; Ai, Y.
2009-12-01
Iron is an important element in magmatic liquid, since its concentration can range up to 18% in some basaltic liquids, and it has two oxidation states. In order to model magmatic processes, thermodynamic descriptions of silicate melts must include precise information for both the FeO and Fe2O3 components. Currently, the partial molar volume of FeO is not as well known as that for Fe2O3 because of the difficulty of performing double-bob density measurements under reducing conditions. Yet these data are required in order to convert sound speed measurements on FeO-bearing liquids into compressibility data, which in turn are needed extend density models for magmatic liquids to elevated pressures. Moreover, there is growing evidence from the spectroscopic literature that Fe2+ occurs in 4, 5, and 6-fold coordination in silicate melts, and thus it is possible that the partial molar volume and compressibility of FeO may vary with Fe2+ coordination, and thus with melt composition. To explore these issues, we have conducted both density and relaxed sound speed measurements on liquids in the CaO-FeO-SiO2 system, where the CaO/SiO2 ratio was systematically varied at constant FeO concentration (40 mol%). Density was measured between 1594 and 1813K with the double-bob Archimedean method using molybdenum bobs and crucible in a reducing gas (1%CO-99%Ar) environment. The sounds speeds were measured under similar conditions with a frequency-sweep acoustic interferometer. The derived partial molar volume of FeO increases systematically from 13.7 to 15.2 cm3/mol at 1673 K as the CaO/SiO2 ratio increases and the Fe2+ coordination number decreases. From a comparison with the crystalline volume of FeO (halite structure; 12.06 cm3/mol), which serves as a lower limit for VFeO in silicate liquids when Fe2+ is in 6-fold coordination, we estimate that the average Fe2+ coordination in our experimental melts extends up to values between 5 and 4, consistent with the spectroscopic literature. The partial molar compressibility of FeO also increases systematically as Fe2+ coordination decreases, and its maximum measured value (7.01 x 10-2 GPa-1) is nearly identical to that for the SiO2 component in 4-fold coordination (7.14 x 10-2 GPa-1) and is considerably larger than that for the relatively incompressible component MgO (0.65 x 10-2 GPa-1). Thus, our data indicate that the volumetric properties of FeO component have more in common with those for SiO2 than for MgO.
NASA Astrophysics Data System (ADS)
Yamauchi, Makoto; Iwamoto, Kazuyo
2010-05-01
Line heating is a skilled task in shipbuilding to shape the outer plates of ship hulls. Real-time information on the deformation of the plates during the task would be helpful to workers performing this process. Therefore, we herein propose an interactive scheme for supporting workers performing line heating; the system provides such information through an optical shape measurement instrument combined with an augmented reality (AR) system. The instrument was designed and fabricated so that the measured data were represented using coordinates based on fiducial markers. Since the markers were simultaneously used in the AR system for the purpose of positioning, the data could then be displayed to the workers through a head-mounted display as a virtual image overlaid on the plates. Feedback of the shape measurement results was thus performed in real time using the proposed system.
Automatic concrete cracks detection and mapping of terrestrial laser scan data
NASA Astrophysics Data System (ADS)
Rabah, Mostafa; Elhattab, Ahmed; Fayad, Atef
2013-12-01
Terrestrial laser scanning has become one of the standard technologies for object acquisition in surveying engineering. The high spatial resolution of imaging and the excellent capability of measuring the 3D space by laser scanning bear a great potential if combined for both data acquisition and data compilation. Automatic crack detection from concrete surface images is very effective for nondestructive testing. The crack information can be used to decide the appropriate rehabilitation method to fix the cracked structures and prevent any catastrophic failure. In practice, cracks on concrete surfaces are traced manually for diagnosis. On the other hand, automatic crack detection is highly desirable for efficient and objective crack assessment. The current paper submits a method for automatic concrete cracks detection and mapping from the data that was obtained during laser scanning survey. The method of cracks detection and mapping is achieved by three steps, namely the step of shading correction in the original image, step of crack detection and finally step of crack mapping and processing steps. The detected crack is defined in a pixel coordinate system. To remap the crack into the referred coordinate system, a reverse engineering is used. This is achieved by a hybrid concept of terrestrial laser-scanner point clouds and the corresponding camera image, i.e. a conversion from the pixel coordinate system to the terrestrial laser-scanner or global coordinate system. The results of the experiment show that the mean differences between terrestrial laser scan and the total station are about 30.5, 16.4 and 14.3 mms in x, y and z direction, respectively.
56th Coloquium of the International Astronomical Union
NASA Astrophysics Data System (ADS)
Gaposchkin, E. M.
Geodesy, geophysics, astronomy, and astrophysics are all exploiting the unprecedented progress in the accuracy of metric measurements made from space and the earth's surface. Measurements of polar motion and earth rotation, crustal deformation and displacement, satellite and planetary motion, and the positions of stars and quasars are all being refined. These new measurements are providing information on plate tectonics and earth dynamics, the earth's variable rotation, the evolution of the moon and planets, the scale of the solar system and the universe, and the local space-time metric. A common requirement of all these investigations is the necessity of a well-defined coordinate system (or systems) to which all relevant observations, theories, and models can be referred and which can be used as a basis for discussion. In view of the widespread use and interdisciplinary implications of these observations, there is a need for the definition, practical realization, and international acceptance of a suitable coordinate system (or systems) to facilitate such work. The need, the scope of the issues, and the nontriviality of the problem is evidenced by the numerous specialized symposia organized during the past dozen years: Stressa [Markowitz and Guinot, 1968], Morioka [Melchior and Yumi, 1972; Yumi, 1971], Torun [Koaczek and Weiffenbach, 1974], Columbus [Mueller, 1975, 1978], Kiev [Federov et al, 1980], San Fernando [McCarthy and Pilkington, 1979], and recently, Warsaw [Gaposchkin and Ko/aczek, 1981]. The Warsaw meeting (September 8-12, 1980) is the subject of this review.
New measuring system for the distribution of a magnetic force by using an optical fiber
NASA Astrophysics Data System (ADS)
Ishigaki, H.; Oya, T.; Itoh, M.; Hida, A.; Iwata, K.
1993-01-01
A new measuring system using an optical fiber and a position sensing photodetector was developed to measure a three-dimensional distribution of a magnetic force. A steel ball attached to a cantilever made of an optical fiber generated force in a magnetic field. The displacement of the ball due to the force was detected by a position-sensing photodetector with the capability of detecting two-directional coordinates of the position. By scanning the sensing system in a magnetic field, we obtained distributions of two-directional component of the magnetic force vector. The component represents the gradient of a squared magnetic field. The usefulness of the system for measuring the magnetic field distribution in a narrow clearance and for evaluating superconducting machine components such as magnetic bearings was verified experimentally.
Stress Physiology in Infancy and Early Childhood: Cortisol Flexibility, Attunement and Coordination.
Atkinson, L; Jamieson, B; Khoury, J; Ludmer, J; Gonzalez, A
2016-08-01
Research on stress physiology in infancy has assumed increasing importance due to its lifelong implications. In this review, we focus on measurement of hypothalamic-pituitary-adrenal (HPA) function, in particular, and on complementary autonomic processes. We suggest that the measure of HPA function has been overly exclusive, focusing on individual reactivity to single, pragmatically selected laboratory challenges. We advocate use of multiple, strategically chosen challenges and within-subject designs. By administering one challenge that typically does not provoke reactivity and another that does, it is possible to represent allostatic load in terms of "flexibility," the capacity to titrate response to challenge. We also recommend assessing infant reactivity in the context of the primary caregiver's physiological function. Infant-mother "attunement" is central to developmental psychology, permeating diverse developmental domains with varied consequences. A review of adrenocortical attunement suggests that attunement is a reliable process, manifest across varied populations. However, attunement appears stronger in the context of more highly stressful circumstances, such that administration of multiple, selected challenges may help evaluate the degree to which individuals titrate attunement to challenge and determine the correlates of this differential attunement. Finally, we advocate studying the "coordination" of HPA function with other aspects of stress physiology and variation in the degree of this coordination. The use of multiple stressors is important here because each stress system is differentially sensitive to different types of challenge. Therefore, use of single stressors in between-subject designs impedes full recognition of the role played by each system. Overall, we recommend measure of flexibility, attunement, and coordination in the context of multiple challenges to capture allostasis in environmental and physiological context. The simultaneous use of such inclusive and integrative metrics may yield more reliable findings than has hitherto been the case. The interrelation of these metrics can be understood in the context of the adaptive calibration model.. © 2016 British Society for Neuroendocrinology.
Method of orthogonally splitting imaging pose measurement
NASA Astrophysics Data System (ADS)
Zhao, Na; Sun, Changku; Wang, Peng; Yang, Qian; Liu, Xintong
2018-01-01
In order to meet the aviation's and machinery manufacturing's pose measurement need of high precision, fast speed and wide measurement range, and to resolve the contradiction between measurement range and resolution of vision sensor, this paper proposes an orthogonally splitting imaging pose measurement method. This paper designs and realizes an orthogonally splitting imaging vision sensor and establishes a pose measurement system. The vision sensor consists of one imaging lens, a beam splitter prism, cylindrical lenses and dual linear CCD. Dual linear CCD respectively acquire one dimensional image coordinate data of the target point, and two data can restore the two dimensional image coordinates of the target point. According to the characteristics of imaging system, this paper establishes the nonlinear distortion model to correct distortion. Based on cross ratio invariability, polynomial equation is established and solved by the least square fitting method. After completing distortion correction, this paper establishes the measurement mathematical model of vision sensor, and determines intrinsic parameters to calibrate. An array of feature points for calibration is built by placing a planar target in any different positions for a few times. An terative optimization method is presented to solve the parameters of model. The experimental results show that the field angle is 52 °, the focus distance is 27.40 mm, image resolution is 5185×5117 pixels, displacement measurement error is less than 0.1mm, and rotation angle measurement error is less than 0.15°. The method of orthogonally splitting imaging pose measurement can satisfy the pose measurement requirement of high precision, fast speed and wide measurement range.
Vimalananda, Varsha G; Dvorin, Kelly; Fincke, B Graeme; Tardiff, Nicole; Bokhour, Barbara G
Successful coordination of specialty care requires understanding the perspectives of patients, primary care providers, and specialists-that is, the specialty care "triad." This study used qualitative methods to compare these perspectives in an integrated health care system, using diabetes specialty care as an exemplar. Primary care providers and endocrinologists relied on interclinician relationships to coordinate care. Clinicians rarely included patients or other staff in their conceptualization of specialty care coordination. Patients often assumed responsibility for specialty care coordination but struggled to succeed. We identified several opportunities to improve coordination across the triad. In an integrated medical system, the shared organizational structure can facilitate these efforts.
Pesyna, Colin; Pundi, Krishna; Flanders, Martha
2011-03-09
The neural control of hand movement involves coordination of the sensory, motor, and memory systems. Recent studies have documented the motor coordinates for hand shape, but less is known about the corresponding patterns of somatosensory activity. To initiate this line of investigation, the present study characterized the sense of hand shape by evaluating the influence of differences in the amount of grasping or twisting force, and differences in forearm orientation. Human subjects were asked to use the left hand to report the perceived shape of the right hand. In the first experiment, six commonly grasped items were arranged on the table in front of the subject: bottle, doorknob, egg, notebook, carton, and pan. With eyes closed, subjects used the right hand to lightly touch, forcefully support, or imagine holding each object, while 15 joint angles were measured in each hand with a pair of wired gloves. The forces introduced by supporting or twisting did not influence the perceptual report of hand shape, but for most objects, the report was distorted in a consistent manner by differences in forearm orientation. Subjects appeared to adjust the intrinsic joint angles of the left hand, as well as the left wrist posture, so as to maintain the imagined object in its proper spatial orientation. In a second experiment, this result was largely replicated with unfamiliar objects. Thus, somatosensory and motor information appear to be coordinated in an object-based, spatial-coordinate system, sensitive to orientation relative to gravitational forces, but invariant to grasp forcefulness.
New approach to isometric transformations in oblique local coordinate systems of reference
NASA Astrophysics Data System (ADS)
Stępień, Grzegorz; Zalas, Ewa; Ziębka, Tomasz
2017-12-01
The research article describes a method of isometric transformation and determining an exterior orientation of a measurement instrument. The method is based on a designation of a "virtual" translation of two relative oblique orthogonal systems to a common, known in the both systems, point. The relative angle orientation of the systems does not change as each of the systems is moved along its axis. The next step is the designation of the three rotation angles (e.g. Tait-Bryan or Euler angles), transformation of the system convoluted at the calculated angles and moving the system to the initial position where the primary coordinate system was. This way eliminates movements of the systems from the calculations and makes it possible to calculate angles of mutual rotation angles of two orthogonal systems primarily involved in the movement. The research article covers laboratory calculations for simulated data. The accuracy of the results is 10-6 m (10-3 regarding the accuracy of the input data). This confi rmed the correctness of the assumed calculation method. In the following step the method was verifi ed under fi eld conditions, where the accuracy of the method raised to 0.003 m. The proposed method enabled to make the measurements with the oblique and uncentered instrument, e.g. total station instrument set over an unknown point. This is the reason why the method was named by the authors as Total Free Station - TFS. The method may be also used for isometric transformations for photogrammetric purposes.
Analysis of Photogrammetry Data from ISIM Mockup, June 1, 2007
NASA Technical Reports Server (NTRS)
Nowak, Maria; Hill, Mike
2007-01-01
During ground testing of the Integrated Science Instrument Module (ISIM) for the James Webb Space Telescope (JWST), the ISIM Optics group plans to use a Photogrammetry Measurement System for cryogenic calibration of specific target points on the ISIM composite structure and Science Instrument optical benches and other GSE equipment. This testing will occur in the Space Environmental Systems (SES) chamber at Goddard Space Flight Center. Close range photogrammetry is a 3 dimensional metrology system using triangulation to locate custom targets in 3 coordinates via a collection of digital photographs taken from various locations and orientations. These photos are connected using coded targets, special targets that are recognized by the software and can thus correlate the images to provide a 3 dimensional map of the targets, and scaled via well calibrated scale bars. Photogrammetry solves for the camera location and coordinates of the targets simultaneously through the bundling procedure contained in the V-STARS software.
Framework for 2D-3D image fusion of infrared thermography with preoperative MRI.
Hoffmann, Nico; Weidner, Florian; Urban, Peter; Meyer, Tobias; Schnabel, Christian; Radev, Yordan; Schackert, Gabriele; Petersohn, Uwe; Koch, Edmund; Gumhold, Stefan; Steiner, Gerald; Kirsch, Matthias
2017-11-27
Multimodal medical image fusion combines information of one or more images in order to improve the diagnostic value. While previous applications mainly focus on merging images from computed tomography, magnetic resonance imaging (MRI), ultrasonic and single-photon emission computed tomography, we propose a novel approach for the registration and fusion of preoperative 3D MRI with intraoperative 2D infrared thermography. Image-guided neurosurgeries are based on neuronavigation systems, which further allow us track the position and orientation of arbitrary cameras. Hereby, we are able to relate the 2D coordinate system of the infrared camera with the 3D MRI coordinate system. The registered image data are now combined by calibration-based image fusion in order to map our intraoperative 2D thermographic images onto the respective brain surface recovered from preoperative MRI. In extensive accuracy measurements, we found that the proposed framework achieves a mean accuracy of 2.46 mm.
Asymmetric interjoint feedback contributes to postural control of redundant multi-link systems
NASA Astrophysics Data System (ADS)
Bunderson, Nathan E.; Ting, Lena H.; Burkholder, Thomas J.
2007-09-01
Maintaining the postural configuration of a limb such as an arm or leg is a fundamental neural control task that involves the coordination of multiple linked body segments. Biological systems are known to use a complex network of inter- and intra-joint feedback mechanisms arising from muscles, spinal reflexes and higher neuronal structures to stabilize the limbs. While previous work has shown that a small amount of asymmetric heterogenic feedback contributes to the behavior of these systems, a satisfactory functional explanation for this non-conservative feedback structure has not been put forth. We hypothesized that an asymmetric multi-joint control strategy would confer both an energetic and stability advantage in maintaining endpoint position of a kinematically redundant system. We tested this hypothesis by using optimal control models incorporating symmetric versus asymmetric feedback with the goal of maintaining the endpoint location of a kinematically redundant, planar limb. Asymmetric feedback improved endpoint control performance of the limb by 16%, reduced energetic cost by 21% and increased interjoint coordination by 40% compared to the symmetric feedback system. The overall effect of the asymmetry was that proximal joint motion resulted in greater torque generation at distal joints than vice versa. The asymmetric organization is consistent with heterogenic stretch reflex gains measured experimentally. We conclude that asymmetric feedback has a functionally relevant role in coordinating redundant degrees of freedom to maintain the position of the hand or foot.
Asymmetric interjoint feedback contributes to postural control of redundant multi-link systems
Bunderson, Nathan E.; Ting, Lena H.; Burkholder, Thomas J.
2008-01-01
Maintaining the postural configuration of a limb such as an arm or leg is a fundamental neural control task that involves the coordination of multiple linked body segments. Biological systems are known to use a complex network of inter- and intra-joint feedback mechanisms arising from muscles, spinal reflexes, and higher neuronal structures to stabilize the limbs. While previous work has shown that a small amount of asymmetric heterogenic feedback contributes to the behavior of these systems, a satisfactory functional explanation for this nonconservative feedback structure has not been put forth. We hypothesized that an asymmetric multi-joint control strategy would confer both an energetic and stability advantage in maintaining endpoint position of a kinematically redundant system. We tested this hypothesis by using optimal control models incorporating symmetric versus asymmetric feedback with the goal of maintaining the endpoint location of a kinematically redundant, planar limb. Asymmetric feedback improved endpoint control performance of the limb by 16%, reduced energetic cost by 21% and increased interjoint coordination by 40% compared to the symmetric feedback system. The overall effect of the asymmetry was that proximal joint motion resulted in greater torque generation at distal joints than vice versa. The asymmetric organization is consistent with heterogenic stretch reflex gains measured experimentally. We conclude that asymmetric feedback has a functionally relevant role in coordinating redundant degrees of freedom to maintain the position of the hand or foot. PMID:17873426
Free energy from molecular dynamics with multiple constraints
NASA Astrophysics Data System (ADS)
den Otter, W. K.; Briels, W. J.
In molecular dynamics simulations of reacting systems, the key step to determining the equilibrium constant and the reaction rate is the calculation of the free energy as a function of the reaction coordinate. Intuitively the derivative of the free energy is equal to the average force needed to constrain the reaction coordinate to a constant value, but the metric tensor effect of the constraint on the sampled phase space distribution complicates this relation. The appropriately corrected expression for the potential of mean constraint force method (PMCF) for systems in which only the reaction coordinate is constrained was published recently. Here we will consider the general case of a system with multiple constraints. This situation arises when both the reaction coordinate and the 'hard' coordinates are constrained, and also in systems with several reaction coordinates. The obvious advantage of this method over the established thermodynamic integration and free energy perturbation methods is that it avoids the cumbersome introduction of a full set of generalized coordinates complementing the constrained coordinates. Simulations of n -butane and n -pentane in vacuum illustrate the method.
3-D Deformation analysis via invariant geodetic obsevations.
NASA Astrophysics Data System (ADS)
Ardalan, A.; Esmaeili, R.
2003-04-01
In this paper a new method for 3-D deformation analysis based on invariant observations like distances and spatial angles is presented. Displacement field that is used in the classical deformation analysis is not reliable because the stability of the coordinate systems between successive epochs of observations cannot be guaranteed. On the contrary distances and spatial angles, i.e. measurements that are related to geometry between the constituent points of an object is independent of the definition of coordinate system. In this paper we have devised a new approach for the calculation of elements of the strain tensor directly from the geometrical observations such as angels and distances. This new method besides enjoys 3-D nature and as such guarantees the complete deformation study in 3-D space.
A proposal of an architecture for the coordination level of intelligent machines
NASA Technical Reports Server (NTRS)
Beard, Randall; Farah, Jeff; Lima, Pedro
1993-01-01
The issue of obtaining a practical, structured, and detailed description of an architecture for the Coordination Level of Center for Intelligent Robotic Systems for Sapce Exploration (CIRSSE) Testbed Intelligent Controller is addressed. Previous theoretical and implementation works were the departure point for the discussion. The document is organized as follows: after this introductory section, section 2 summarizes the overall view of the Intelligent Machine (IM) as a control system, proposing a performance measure on which to base its design. Section 3 addresses with some detail implementation issues. An hierarchic petri-net with feedback-based learning capabilities is proposed. Finally, section 4 is an attempt to address the feedback problem. Feedback is used for two functions: error recovery and reinforcement learning of the correct translations for the petri-net transitions.
Adaptive Control Strategies for Interlimb Coordination in Legged Robots: A Review
Aoi, Shinya; Manoonpong, Poramate; Ambe, Yuichi; Matsuno, Fumitoshi; Wörgötter, Florentin
2017-01-01
Walking animals produce adaptive interlimb coordination during locomotion in accordance with their situation. Interlimb coordination is generated through the dynamic interactions of the neural system, the musculoskeletal system, and the environment, although the underlying mechanisms remain unclear. Recently, investigations of the adaptation mechanisms of living beings have attracted attention, and bio-inspired control systems based on neurophysiological findings regarding sensorimotor interactions are being developed for legged robots. In this review, we introduce adaptive interlimb coordination for legged robots induced by various factors (locomotion speed, environmental situation, body properties, and task). In addition, we show characteristic properties of adaptive interlimb coordination, such as gait hysteresis and different time-scale adaptations. We also discuss the underlying mechanisms and control strategies to achieve adaptive interlimb coordination and the design principle for the control system of legged robots. PMID:28878645
Understanding Confounding Effects in Linguistic Coordination: An Information-Theoretic Approach
Gao, Shuyang; Ver Steeg, Greg; Galstyan, Aram
2015-01-01
We suggest an information-theoretic approach for measuring stylistic coordination in dialogues. The proposed measure has a simple predictive interpretation and can account for various confounding factors through proper conditioning. We revisit some of the previous studies that reported strong signatures of stylistic accommodation, and find that a significant part of the observed coordination can be attributed to a simple confounding effect—length coordination. Specifically, longer utterances tend to be followed by longer responses, which gives rise to spurious correlations in the other stylistic features. We propose a test to distinguish correlations in length due to contextual factors (topic of conversation, user verbosity, etc.) and turn-by-turn coordination. We also suggest a test to identify whether stylistic coordination persists even after accounting for length coordination and contextual factors. PMID:26115446
Interactive display of molecular models using a microcomputer system
NASA Technical Reports Server (NTRS)
Egan, J. T.; Macelroy, R. D.
1980-01-01
A simple, microcomputer-based, interactive graphics display system has been developed for the presentation of perspective views of wire frame molecular models. The display system is based on a TERAK 8510a graphics computer system with a display unit consisting of microprocessor, television display and keyboard subsystems. The operating system includes a screen editor, file manager, PASCAL and BASIC compilers and command options for linking and executing programs. The graphics program, written in USCD PASCAL, involves the centering of the coordinate system, the transformation of centered model coordinates into homogeneous coordinates, the construction of a viewing transformation matrix to operate on the coordinates, clipping invisible points, perspective transformation and scaling to screen coordinates; commands available include ZOOM, ROTATE, RESET, and CHANGEVIEW. Data file structure was chosen to minimize the amount of disk storage space. Despite the inherent slowness of the system, its low cost and flexibility suggests general applicability.
NASA Astrophysics Data System (ADS)
Krzan, Grzegorz; Stępniak, Katarzyna
2017-09-01
In high-accuracy positioning using GNSS, the most common solution is still relative positioning using double-difference observations of dual-frequency measurements. An increasingly popular alternative to relative positioning are undifferenced approaches, which are designed to make full use of modern satellite systems and signals. Positions referenced to global International Terrestrial Reference Frame (ITRF2008) obtained from Precise Point Positioning (PPP) or Undifferenced (UD) network solutions have to be transformed to national (regional) reference frame, which introduces additional bases related to the transformation process. In this paper, satellite observations from two test networks using different observation time series were processed. The first test concerns the positioning accuracy from processing one year of dual-frequency GPS observations from 14 EUREF Permanent Network (EPN) stations using NAPEOS 3.3.1 software. The results were transformed into a national reference frame (PL-ETRF2000) and compared to positions from an EPN cumulative solution, which was adopted as the true coordinates. Daily observations were processed using PPP and UD multi-station solutions to determine the final accuracy resulting from satellite positioning, the transformation to national coordinate systems and Eurasian intraplate plate velocities. The second numerical test involved similar processing strategies of post-processing carried out using different observation time series (30 min., 1 hour, 2 hours, daily) and different classes of GNSS receivers. The centimeter accuracy of results presented in the national coordinate system satisfies the requirements of many surveying and engineering applications.
NASA Astrophysics Data System (ADS)
Bushuev, F.; Kaliuzhnyi, M.; Sybiryakova, Y.; Shulga, O.; Moskalenko, S.; Balagura, O.; Kulishenko, V.
2016-10-01
The results of the ongoing monitoring of the position of geostationary telecommunication satellite Eutelsat-13B (13° East) are presented in the article. The results were obtained using a radio engineering complex (RC) of four stations receiving digital satellite television and a data processing centre. The stations are located in Kyiv, Mukachevo, Kharkiv and Mykolaiv. The equipment of each station allows synchronous recording (by the GPS) of fragments of DVB-S signal from the quadrature detector output of the satellite television receiver. Samples of the complex signal are archived and sent to the data processing center through the Internet. Here three linearly independent slant range differences (Δr) for three pairs of the stations are determined as a result of correlation processing of received signals. Every second measured values of Δr are used to calculate Cartesian coordinates (XYZ) of the satellite in the coordinate system WGS84 by multilateration method. The time series of Δr, X, Y and Z obtained during continuous observations from March to May 2015 are presented in the article. Single-measurement errors of Δr, X, Y and Z are equal to 2.6 m, 3540 m, 705 m and 455 m, respectively. The complex is compared with known analogues. Ways of reduction of measurement errors of satellite coordinates are considered. The radio engineering complex could be considered a prototype of a system of independent ongoing monitoring of the position of geostationary telecommunication satellites.
Medintz, I. L.; Konnert, J. H.; Clapp, A. R.; Stanish, I.; Twigg, M. E.; Mattoussi, H.; Mauro, J. M.; Deschamps, J. R.
2004-01-01
The first generation of luminescent semiconductor quantum dot (QD)-based hybrid inorganic biomaterials and sensors is now being developed. It is crucial to understand how bioreceptors, especially proteins, interact with these inorganic nanomaterials. As a model system for study, we use Rhodamine red-labeled engineered variants of Escherichia coli maltose-binding protein (MBP) coordinated to the surface of 555-nm emitting CdSe-ZnS core–shell QDs. Fluorescence resonance energy transfer studies were performed to determine the distance from each of six unique MBP-Rhodamine red dye-acceptor locations to the center of the energy-donating QD. In a strategy analogous to a nanoscale global positioning system determination, we use the intraassembly distances determined from the fluorescence resonance energy transfer measurements, the MBP crystallographic coordinates, and a least-squares approach to determine the orientation of the MBP relative to the QD surface. Results indicate that MBP has a preferred orientation on the QD surface. The refined model is in agreement with other evidence, which indicates coordination of the protein to the QD occurs by means of its C-terminal pentahistidine tail, and the size of the QD estimated from the model is in good agreement with physical measurements of QD size. The approach detailed here may be useful in determining the orientation of proteins in other hybrid protein–nanoparticle materials. To our knowledge, this is the first structural model of a hybrid luminescent QD-protein receptor assembly elucidated by using spectroscopic measurements in conjunction with crystallographic and other data. PMID:15210939
Combine harvester monitor system based on wireless sensor network
USDA-ARS?s Scientific Manuscript database
A measurement method based on Wireless Sensor Network (WSN) was developed to monitor the working condition of combine harvester for remote application. Three JN5139 modules were chosen for sensor data acquisition and another two as a router and a coordinator, which could create a tree topology netwo...
DOT National Transportation Integrated Search
2010-04-21
Terrorist attacks on surface transportation facilities in Moscow, Mumbai, London, and Madrid caused casualties and highlighted the vulnerability of such systems. The Transportation Security Administration (TSA), within the Department of Homeland Secu...
Real-time 3D measurement based on structured light illumination considering camera lens distortion
NASA Astrophysics Data System (ADS)
Feng, Shijie; Chen, Qian; Zuo, Chao; Sun, Jiasong; Yu, ShiLing
2014-12-01
Optical three-dimensional (3-D) profilometry is gaining increasing attention for its simplicity, flexibility, high accuracy, and non-contact nature. Recent advances in imaging sensors and digital projection technology further its progress in high-speed, real-time applications, enabling 3-D shapes reconstruction of moving objects and dynamic scenes. In traditional 3-D measurement system where the processing time is not a key factor, camera lens distortion correction is performed directly. However, for the time-critical high-speed applications, the time-consuming correction algorithm is inappropriate to be performed directly during the real-time process. To cope with this issue, here we present a novel high-speed real-time 3-D coordinates measuring technique based on fringe projection with the consideration of the camera lens distortion. A pixel mapping relation between a distorted image and a corrected one is pre-determined and stored in computer memory for real-time fringe correction. And a method of lookup table (LUT) is introduced as well for fast data processing. Our experimental results reveal that the measurement error of the in-plane coordinates has been reduced by one order of magnitude and the accuracy of the out-plane coordinate been tripled after the distortions being eliminated. Moreover, owing to the merit of the LUT, the 3-D reconstruction can be achieved at 92.34 frames per second.
One-shot exogenous interventions increase subsequent coordination in Denmark, Spain and Ghana
Thorsen, Bo Jellesmark
2017-01-01
Everyday, we are bombarded with periodic, exogenous appeals and instructions on how to behave. How do these appeals and instructions affect subsequent coordination? Using experimental methods, we investigate how a one-time exogenous instruction affects subsequent coordination among individuals in a lab. Participants play a minimum effort game repeated 5 times under fixed matching with a one-time behavioral instruction in either the first or second round. Since coordination behavior may vary across countries, we run experiments in Denmark, Spain and Ghana, and map cross-country rankings in coordination with known national measures of fractualization, uncertainty avoidance and long-term orientation. Our results show that exogenous interventions increase subsequent coordination, with earlier interventions yielding better coordination than later interventions. We also find that cross-country rankings in coordination map with published national measures of fractualization, uncertainty avoidance, and long-term orientation. PMID:29145411
One-shot exogenous interventions increase subsequent coordination in Denmark, Spain and Ghana.
Abatayo, Anna Lou; Thorsen, Bo Jellesmark
2017-01-01
Everyday, we are bombarded with periodic, exogenous appeals and instructions on how to behave. How do these appeals and instructions affect subsequent coordination? Using experimental methods, we investigate how a one-time exogenous instruction affects subsequent coordination among individuals in a lab. Participants play a minimum effort game repeated 5 times under fixed matching with a one-time behavioral instruction in either the first or second round. Since coordination behavior may vary across countries, we run experiments in Denmark, Spain and Ghana, and map cross-country rankings in coordination with known national measures of fractualization, uncertainty avoidance and long-term orientation. Our results show that exogenous interventions increase subsequent coordination, with earlier interventions yielding better coordination than later interventions. We also find that cross-country rankings in coordination map with published national measures of fractualization, uncertainty avoidance, and long-term orientation.
High precision applications of the global positioning system
NASA Technical Reports Server (NTRS)
Lichten, Stephen M.
1991-01-01
The Global Positioning System (GPS) is a constellation of U.S. defense navigation satellites which can be used for military and civilian positioning applications. A wide variety of GPS scientific applications were identified and precise positioning capabilities with GPS were already demonstrated with data available from the present partial satellite constellation. Expected applications include: measurements of Earth crustal motion, particularly in seismically active regions; measurements of the Earth's rotation rate and pole orientation; high-precision Earth orbiter tracking; surveying; measurements of media propagation delays for calibration of deep space radiometric data in support of NASA planetary missions; determination of precise ground station coordinates; and precise time transfer worldwide.
Bioluminescence Truth Data Measurement and Signature Detection
2006-01-01
bioluminescence activity and related forcing factors. Kilroy sensors are shown attached to pilings with the senor system below water and the cell phone based...communications module attached to the top of the piling. A cell phone tower represents communication of data to shore. Also shown are distributed...installation are located based on GPS coordinates telemetered by the cell phone module. Icons point in direction of most recently measured flow and
Wong, Janice L.; Higgins, Robert F.; Bhowmick, Indrani; Cao, David Xi; Szigethy, Géza; Ziller, Joseph W.
2016-01-01
A new bimetallic platform comprising a six-coordinate Fe(ONO)2 unit bound to an (ONO)M (M = Fe, Zn) has been discovered ((ONOcat)H3 = bis(3,5-di-tert-butyl-2-phenol)amine). Reaction of Fe(ONO)2 with either (ONOcat)Fe(py)3 or with (ONOq)FeCl2 under reducing conditions led to the formation of the bimetallic complex Fe2(ONO)3, which includes unique five- and six-coordinate iron centers. Similarly, the reaction of Fe(ONO)2 with the new synthon (ONOsq˙)Zn(py)2 led to the formation of the heterobimetallic complex FeZn(ONO)3, with a six-coordinate iron center and a five-coordinate zinc center. Both bimetallic complexes were characterized by single-crystal X-ray diffraction studies, solid-state magnetic measurements, and multiple spectroscopic techniques. The magnetic data for FeZn(ONO)3 are consistent with a ground state S = 3/2 spin system, generated from a high-spin iron(ii) center that is antiferromagnetically coupled to a single (ONOsq˙)2– radical ligand. In the case of Fe2(ONO)3, the magnetic data revealed a ground state S = 7/2 spin system arising from the interactions of one high-spin iron(ii) center, one high-spin iron(iii) center, and two (ONOsq˙)2– radical ligands. PMID:28808535
Terkildsen, Morten Deleuran; Wittrup, Inge; Burau, Viola
2015-01-01
Many highly formalised approaches to coordination poorly fit public health and recent studies call for coordination based on complex adaptive systems. Our contribution is two-fold. Empirically, we focus on public health, and theoretically we build on the patient perspective and treat coordination as a process of contingent, two-level negotiations of user needs. The paper draws on the concept of user needs-based coordination and sees coordination as a process, whereby needs emerging from the life world of the user are made amenable to the health system through negotiations. The analysis is based on an explorative case study of a health promotion initiative in Denmark. It adopts an anthropological qualitative approach and uses a range of qualitative data. The analysis identifies four strategies of coordination: the coordinator focusing on the individual user or on relations with other professionals; and the manager coaching the coordinator or providing structural support. Crucially, the coordination strategies by management remain weak as they do not directly relate to specific user needs. In process of bottom-up negotiations user needs become blurred and this is especially a challenge for management. The study therefore calls for an increased focus on the level nature of negotiations to bridge the gap that currently weakens coordination strategies by management.
The Geolocation model for lunar-based Earth observation
NASA Astrophysics Data System (ADS)
Ding, Yixing; Liu, Guang; Ren, Yuanzhen; Ye, Hanlin; Guo, Huadong; Lv, Mingyang
2016-07-01
In recent years, people are more and more aware of that the earth need to treated as an entirety, and consequently to be observed in a holistic, systematic and multi-scale view. However, the interaction mechanism between the Earth's inner layers and outer layers is still unclear. Therefore, we propose to observe the Earth's inner layers and outer layers instantaneously on the Moon which may be helpful to the studies in climatology, meteorology, seismology, etc. At present, the Moon has been proved to be an irreplaceable platform for Earth's outer layers observation. Meanwhile, some discussions have been made in lunar-based observation of the Earth's inner layers, but the geolocation model of lunar-based observation has not been specified yet. In this paper, we present a geolocation model based on transformation matrix. The model includes six coordinate systems: The telescope coordinate system, the lunar local coordinate system, the lunar-reference coordinate system, the selenocentric inertial coordinate system, the geocentric inertial coordinate system and the geo-reference coordinate system. The parameters, lncluding the position of the Sun, the Earth, the Moon, the libration and the attitude of the Earth, can be acquired from the Ephemeris. By giving an elevation angle and an azimuth angle of the lunar-based telescope, this model links the image pixel to the ground point uniquely.
Bergeron, Susie; Flint, Hilary; Hansen, Zeynep
2018-05-14
Concussion, or mild traumatic brain injury, especially among young children, teenagers, and young adults, is a significant problem in Ada County, Idaho, and the United States. Although much has been learned about concussion, considerable controversy and gaps in knowledge still exist in many areas of research, leading to variation in concussion assessment, treatment, and management protocols. Health systems can positively impact concussion outcomes through community education and outreach, and provision of timely, coordinated, evidence-based clinical care. Collectively, these measures serve to reduce concussion incidence (primary prevention), enable more timely recognition of concussion by parents, coaches, and teachers of youth athletes (secondary prevention), and improve treatment of concussion after it has occurred (tertiary prevention). Using the concussion prevention and clinical care coordination activities of St. Luke's Health System in Idaho as a benchmark, this analysis estimates the economic value of these preventive measures, in particular those preventive measures that target the pediatric population, for Ada County and the state of Idaho, and includes both year of injury and long-term costs of concussion. This study adopts a societal perspective, incorporating savings in direct medical, indirect, and quality of life costs.
The GMOS cyber(e)-infrastructure: advanced services for supporting science and policy.
Cinnirella, S; D'Amore, F; Bencardino, M; Sprovieri, F; Pirrone, N
2014-03-01
The need for coordinated, systematized and catalogued databases on mercury in the environment is of paramount importance as improved information can help the assessment of the effectiveness of measures established to phase out and ban mercury. Long-term monitoring sites have been established in a number of regions and countries for the measurement of mercury in ambient air and wet deposition. Long term measurements of mercury concentration in biota also produced a huge amount of information, but such initiatives are far from being within a global, systematic and interoperable approach. To address these weaknesses the on-going Global Mercury Observation System (GMOS) project ( www.gmos.eu ) established a coordinated global observation system for mercury as well it retrieved historical data ( www.gmos.eu/sdi ). To manage such large amount of information a technological infrastructure was planned. This high-performance back-end resource associated with sophisticated client applications enables data storage, computing services, telecommunications networks and all services necessary to support the activity. This paper reports the architecture definition of the GMOS Cyber(e)-Infrastructure and the services developed to support science and policy, including the United Nation Environmental Program. It finally describes new possibilities in data analysis and data management through client applications.
A Monocular Vision Measurement System of Three-Degree-of-Freedom Air-Bearing Test-Bed Based on FCCSP
NASA Astrophysics Data System (ADS)
Gao, Zhanyu; Gu, Yingying; Lv, Yaoyu; Xu, Zhenbang; Wu, Qingwen
2018-06-01
A monocular vision-based pose measurement system is provided for real-time measurement of a three-degree-of-freedom (3-DOF) air-bearing test-bed. Firstly, a circular plane cooperative target is designed. An image of a target fixed on the test-bed is then acquired. Blob analysis-based image processing is used to detect the object circles on the target. A fast algorithm (FCCSP) based on pixel statistics is proposed to extract the centers of object circles. Finally, pose measurements can be obtained when combined with the centers and the coordinate transformation relation. Experiments show that the proposed method is fast, accurate, and robust enough to satisfy the requirement of the pose measurement.
Novel Method for Vessel Cross-Sectional Shear Wave Imaging.
He, Qiong; Li, Guo-Yang; Lee, Fu-Feng; Zhang, Qihao; Cao, Yanping; Luo, Jianwen
2017-07-01
Many studies have investigated the applications of shear wave imaging (SWI) to vascular elastography, mainly on the longitudinal section of vessels. It is important to investigate SWI in the arterial cross section when evaluating anisotropy of the vessel wall or complete plaque composition. Here, we proposed a novel method based on the coordinate transformation and directional filter in the polar coordinate system to achieve vessel cross-sectional shear wave imaging. In particular, ultrasound radiofrequency data were transformed from the Cartesian to the polar coordinate system; the radial displacements were then estimated directly. Directional filtering was performed along the circumferential direction to filter out the reflected waves. The feasibility of the proposed vessel cross-sectional shear wave imaging method was investigated through phantom experiments and ex vivo and in vivo studies. Our results indicated that the dispersion relation of the shear wave (i.e., the guided circumferential wave) within the vessel can be measured via the present method, and the elastic modulus of the vessel can be determined. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Insulation co-ordination aspects for power stations with generator circuit-breakers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanders, M.; Koeppl, G.; Kreuzer, J.
1995-07-01
The generator circuit-breaker (gen. c.b.) located between the generator and the step-up transformer, is now being applied world-wide. It has become a recognized electrical component of power stations which is largely due to economical advantages and increased power station availability. Technical protection considerations for power stations have always been the reason for discussion and the object of improvement. With the use of a gen. c.b., some points of view need to be considered anew. Not only the protection system in case of fault conditions will be influenced, but also the insulation co-ordination philosophy. Below the results of some calculations concerningmore » expected overvoltages are presented. These calculations are based on a transformer rated 264/15.5kV, 220 MVA. But the results are transferable to other power plants. Some measurements carried out on a transformer of the same rating complement the calculations. The findings may contribute to an improvement in insulation co-ordination and protection of the electrical system generator--step-up transformer.« less
Adding signals to coordinated traffic signal systems.
DOT National Transportation Integrated Search
1983-08-01
The purpose of this research was to investigate the effect of adding or : removing traffic signals within a coordinated, signal-controlled street network. : The report includes a discussion of coordinated signal systems; arterial street : network con...
Eleventh international symposium on radiopharmaceutical chemistry
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This document contains abstracts of papers which were presented at the Eleventh International Symposium on Radiopharmaceutical Chemistry. Sessions included: radiopharmaceuticals for the dopaminergic system, strategies for the production and use of labelled reactive small molecules, radiopharmaceuticals for measuring metabolism, radiopharmaceuticals for the serotonin and sigma receptor systems, labelled probes for molecular biology applications, radiopharmaceuticals for receptor systems, radiopharmaceuticals utilizing coordination chemistry, radiolabelled antibodies, radiolabelling methods for small molecules, analytical techniques in radiopharmaceutical chemistry, and analytical techniques in radiopharmaceutical chemistry.
Robotic Assistance for Ultrasound-Guided Prostate Brachytherapy
Fichtinger, Gabor; Fiene, Jonathan P.; Kennedy, Christopher W.; Kronreif, Gernot; Iordachita, Iulian; Song, Danny Y.; Burdette, Everette C.; Kazanzides, Peter
2016-01-01
We present a robotically assisted prostate brachytherapy system and test results in training phantoms and Phase-I clinical trials. The system consists of a transrectal ultrasound (TRUS) and a spatially co-registered robot, fully integrated with an FDA-approved commercial treatment planning system. The salient feature of the system is a small parallel robot affixed to the mounting posts of the template. The robot replaces the template interchangeably, using the same coordinate system. Established clinical hardware, workflow and calibration remain intact. In all phantom experiments, we recorded the first insertion attempt without adjustment. All clinically relevant locations in the prostate were reached. Non-parallel needle trajectories were achieved. The pre-insertion transverse and rotational errors (measured with a Polaris optical tracker relative to the template’s coordinate frame) were 0.25mm (STD=0.17mm) and 0.75° (STD=0.37°). In phantoms, needle tip placement errors measured in TRUS were 1.04mm (STD=0.50mm). A Phase-I clinical feasibility and safety trial has been successfully completed with the system. We encountered needle tip positioning errors of a magnitude greater than 4mm in only 2 out of 179 robotically guided needles, in contrast to manual template guidance where errors of this magnitude are much more common. Further clinical trials are necessary to determine whether the apparent benefits of the robotic assistant will lead to improvements in clinical efficacy and outcomes. PMID:18650122
NASA Technical Reports Server (NTRS)
Deines, Steven D.
1992-01-01
Relativity compensations must be made in precise and accurate measurements whenever an observer is accelerated. Although many believe the Earth-centered frame is sufficiently inertial, accelerations of the Earth, as evidenced by the tides, prove that it is technically a noninertial system for even an Earth-based observer. Using the constant speed of light, a set of fixed remote clocks in an inertial frame can be synchronized to a fixed master clock transmitting its time in that frame. The time on the remote clock defines the coordinate time at that coordinate position. However, the synchronization procedure for an accelerated frame is affected, because the distance between the master and remote clocks is altered due to the acceleration of the remote clock toward or away from the master clock during the transmission interval. An exact metric that converts observations from noninertial frames to inertial frames was recently derived. Using this metric with other physical relationships, a new concept of noninertial coordinate time is defined. This noninertial coordinate time includes all relativity compensations. This new issue raises several timekeeping issues, such as proper time standards, time transfer process, and clock synchronization, all in a noninertial frame such as Earth.
NASA Astrophysics Data System (ADS)
Granet, Gérard; Chandezon, Jean
1997-11-01
The method of curvilinear coordinates is formulated using the coordinate transformations given by parametric equations. As an illustration, a translation coordinate system and a relaxation coordinate system are used to calculate the reflectivities of various cycloidal profiles. We show, with this example, that parametric coordinate systems permit one to handle profiles that previously had been out of reach owing to their sharpness.
The Spring 1985 high precision baseline test of the JPL GPS-based geodetic system
NASA Technical Reports Server (NTRS)
Davidson, John M.; Thornton, Catherine L.; Stephens, Scott A.; Blewitt, Geoffrey; Lichten, Stephen M.; Sovers, Ojars J.; Kroger, Peter M.; Skrumeda, Lisa L.; Border, James S.; Neilan, Ruth E.
1987-01-01
The Spring 1985 High Precision Baseline Test (HPBT) was conducted. The HPBT was designed to meet a number of objectives. Foremost among these was the demonstration of a level of accuracy of 1 to 2:10 to the 7th power, or better, for baselines ranging in length up to several hundred kilometers. These objectives were all met with a high degree of success, with respect to the demonstration of system accuracy in particular. The results from six baselines ranging in length from 70 to 729 km were examined for repeatability and, in the case of three baselines, were compared to results from colocated VLBI systems. Repeatability was found to be 5:10 to the 8th power (RMS) for the north baseline coordinate, independent of baseline length, while for the east coordinate RMS repeatability was found to be larger than this by factors of 2 to 4. The GPS-based results were found to be in agreement with those from colocated VLBI measurements, when corrected for the physical separations of the VLBI and CPG antennas, at the level of 1 to 2:10 to the 7th power in all coordinates, independent of baseline length. The results for baseline repeatability are consistent with the current GPA error budget, but the GPS-VLBI intercomparisons disagree at a somewhat larger level than expected. It is hypothesized that these differences may result from errors in the local survey measurements used to correct for the separations of the GPS and VLBI antenna reference centers.
2013-08-19
excellence in linear models , 2010. She successfully defended her dissertation, Linear System Design for Fusion and Compression, on Aug 13, 2013. Her work was...measurements into canonical coordinates, scaling, and rotation; there is a water-filling interpretation; (3) the optimum design of a linear secondary channel of...measurements to fuse with a primary linear channel of measurements maximizes a generalized Rayleigh quotient; (4) the asymptotically optimum
Improving care coordination in primary care.
Wagner, Edward H; Sandhu, Nirmala; Coleman, Katie; Phillips, Kathryn E; Sugarman, Jonathan R
2014-11-01
Although coordinating care is a defining characteristic of primary care, evidence suggests that both patients and providers perceive failures in communication and care when care is received from multiple sources. To examine the utility of a newly developed Care Coordination Model in improving care coordination among participating practices in the Safety Net Medical Home Initiative (SNMHI). In this paper, we used correlation analysis to evaluate whether application of the elements of the Care Coordination Model by SNMHI sites, as measured by the Key Activities Checklist (KAC), was associated with more effective care coordination as measured by another instrument, the PCMH-A. SNMHI measures are practice self-assessments based on the 8 change concepts that define a PCMH, one of which is Care Coordination. For this study, we correlated 12 KAC items that describe activities felt to improve coordination of care with 5 PCMH-A items that indicate the extent to which a practice has developed the capability to effectively coordinate care. Practice staff indicated whether any of the KAC activities were being test, implemented, sustained, or not on 4 occasions. The Care Coordination Model elements-assume accountability, build relationships with care partners, support patients through the referral or transition process, and create connections to support information exchange-were positively correlated with some PCMH-A care coordination items but not others. Activities related to the model were most strongly correlated with following up patients seen in the Emergency Department or discharged from hospital. The analysis provides suggestive evidence that activities consistent with the 4 elements of the Care Coordination Model may enable safety net primary care to better coordinate care for its patients, but further study is clearly needed.
Static Analysis of Large-Scale Multibody System Using Joint Coordinates and Spatial Algebra Operator
Omar, Mohamed A.
2014-01-01
Initial transient oscillations inhibited in the dynamic simulations responses of multibody systems can lead to inaccurate results, unrealistic load prediction, or simulation failure. These transients could result from incompatible initial conditions, initial constraints violation, and inadequate kinematic assembly. Performing static equilibrium analysis before the dynamic simulation can eliminate these transients and lead to stable simulation. Most exiting multibody formulations determine the static equilibrium position by minimizing the system potential energy. This paper presents a new general purpose approach for solving the static equilibrium in large-scale articulated multibody. The proposed approach introduces an energy drainage mechanism based on Baumgarte constraint stabilization approach to determine the static equilibrium position. The spatial algebra operator is used to express the kinematic and dynamic equations of the closed-loop multibody system. The proposed multibody system formulation utilizes the joint coordinates and modal elastic coordinates as the system generalized coordinates. The recursive nonlinear equations of motion are formulated using the Cartesian coordinates and the joint coordinates to form an augmented set of differential algebraic equations. Then system connectivity matrix is derived from the system topological relations and used to project the Cartesian quantities into the joint subspace leading to minimum set of differential equations. PMID:25045732
Omar, Mohamed A
2014-01-01
Initial transient oscillations inhibited in the dynamic simulations responses of multibody systems can lead to inaccurate results, unrealistic load prediction, or simulation failure. These transients could result from incompatible initial conditions, initial constraints violation, and inadequate kinematic assembly. Performing static equilibrium analysis before the dynamic simulation can eliminate these transients and lead to stable simulation. Most exiting multibody formulations determine the static equilibrium position by minimizing the system potential energy. This paper presents a new general purpose approach for solving the static equilibrium in large-scale articulated multibody. The proposed approach introduces an energy drainage mechanism based on Baumgarte constraint stabilization approach to determine the static equilibrium position. The spatial algebra operator is used to express the kinematic and dynamic equations of the closed-loop multibody system. The proposed multibody system formulation utilizes the joint coordinates and modal elastic coordinates as the system generalized coordinates. The recursive nonlinear equations of motion are formulated using the Cartesian coordinates and the joint coordinates to form an augmented set of differential algebraic equations. Then system connectivity matrix is derived from the system topological relations and used to project the Cartesian quantities into the joint subspace leading to minimum set of differential equations.
NASA Astrophysics Data System (ADS)
Qiao, Chuan; Ding, Yalin; Xu, Yongsen; Xiu, Jihong
2018-01-01
To obtain the geographical position of the ground target accurately, a geolocation algorithm based on the digital elevation model (DEM) is developed for an airborne wide-area reconnaissance system. According to the platform position and attitude information measured by the airborne position and orientation system and the gimbal angles information from the encoder, the line-of-sight pointing vector in the Earth-centered Earth-fixed coordinate frame is solved by the homogeneous coordinate transformation. The target longitude and latitude can be solved with the elliptical Earth model and the global DEM. The influences of the systematic error and measurement error on ground target geolocation calculation accuracy are analyzed by the Monte Carlo method. The simulation results show that this algorithm can improve the geolocation accuracy of ground target in rough terrain area obviously. The geolocation accuracy of moving ground target can be improved by moving average filtering (MAF). The validity of the geolocation algorithm is verified by the flight test in which the plane flies at a geodetic height of 15,000 m and the outer gimbal angle is <47°. The geolocation root mean square error of the target trajectory is <45 and <7 m after MAF.
Sensory Feedback Training for Improvement of Finger Perception in Cerebral Palsy
Alves-Pinto, Ana; Aschmann, Simon; Lützow, Ines; Lampe, Renée
2015-01-01
Purpose. To develop and to test a feedback training system for improvement of tactile perception and coordination of fingers in children and youth with cerebral palsy. Methods. The fingers of 7 probands with cerebral palsy of different types and severity were stimulated using small vibration motors integrated in the fingers of a hand glove. The vibration motors were connected through a microcontroller to a computer and to a response 5-button keyboard. By pressing an appropriate keyboard button, the proband must indicate in which finger the vibration was felt. The number of incorrect responses and the reaction time were measured for every finger. The perception and coordination of fingers were estimated before and after two-week training using both clinical tests and the measurements. Results. Proper functioning of the developed system in persons with cerebral palsy was confirmed. The tactile sensation of fingers was improved in five of seven subjects after two weeks of training. There was no clear tendency towards improvement of selective use of fingers. Conclusion. The designed feedback system could be used to train tactile perception of fingers in children and youth with cerebral palsy. An extensive study is required to confirm these findings. PMID:26124965
Sensory Feedback Training for Improvement of Finger Perception in Cerebral Palsy.
Blumenstein, Tobias; Alves-Pinto, Ana; Turova, Varvara; Aschmann, Simon; Lützow, Ines; Lampe, Renée
2015-01-01
Purpose. To develop and to test a feedback training system for improvement of tactile perception and coordination of fingers in children and youth with cerebral palsy. Methods. The fingers of 7 probands with cerebral palsy of different types and severity were stimulated using small vibration motors integrated in the fingers of a hand glove. The vibration motors were connected through a microcontroller to a computer and to a response 5-button keyboard. By pressing an appropriate keyboard button, the proband must indicate in which finger the vibration was felt. The number of incorrect responses and the reaction time were measured for every finger. The perception and coordination of fingers were estimated before and after two-week training using both clinical tests and the measurements. Results. Proper functioning of the developed system in persons with cerebral palsy was confirmed. The tactile sensation of fingers was improved in five of seven subjects after two weeks of training. There was no clear tendency towards improvement of selective use of fingers. Conclusion. The designed feedback system could be used to train tactile perception of fingers in children and youth with cerebral palsy. An extensive study is required to confirm these findings.
Sensitivity vector fields in time-delay coordinate embeddings: theory and experiment.
Sloboda, A R; Epureanu, B I
2013-02-01
Identifying changes in the parameters of a dynamical system can be vital in many diagnostic and sensing applications. Sensitivity vector fields (SVFs) are one way of identifying such parametric variations by quantifying their effects on the morphology of a dynamical system's attractor. In many cases, SVFs are a more effective means of identification than commonly employed modal methods. Previously, it has only been possible to construct SVFs for a given dynamical system when a full set of state variables is available. This severely restricts SVF applicability because it may be cost prohibitive, or even impossible, to measure the entire state in high-dimensional systems. Thus, the focus of this paper is constructing SVFs with only partial knowledge of the state by using time-delay coordinate embeddings. Local models are employed in which the embedded states of a neighborhood are weighted in a way referred to as embedded point cloud averaging. Application of the presented methodology to both simulated and experimental time series demonstrates its utility and reliability.
NASA Technical Reports Server (NTRS)
Thompson, J. F.; Thames, F. C.; Mastin, C. W.
1977-01-01
A method is presented for automatic numerical generation of a general curvilinear coordinate system with coordinate lines coincident with all boundaries of a general multi-connected two-dimensional region containing any number of arbitrarily shaped bodies. No restrictions are placed on the shape of the boundaries, which may even be time-dependent, and the approach is not restricted in principle to two dimensions. With this procedure the numerical solution of a partial differential system may be done on a fixed rectangular field with a square mesh with no interpolation required regardless of the shape of the physical boundaries, regardless of the spacing of the curvilinear coordinate lines in the physical field, and regardless of the movement of the coordinate system in the physical plane. A number of examples of coordinate systems and application thereof to the solution of partial differential equations are given. The FORTRAN computer program and instructions for use are included.
NASA Astrophysics Data System (ADS)
Prenger-Berninghoff, Kathrin; Cortes, V. Juliette; Aye, Zar Chi; Sprague, Teresa
2013-04-01
The management of natural hazards involves, as generally known, the four stages of the risk management cycle: Prevention, preparedness, response and recovery. Accordingly, the mitigation of disasters can be performed in terms of short-term and long-term purposes. Whereas emergency management or civil protection helps to strengthen a community's capacity to be better prepared for natural hazards and to better respond in case a disaster strikes, thus addressing the short-term perspective, spatial planning serves long-term planning goals and can therefore implement long-term prevention measures. A purposefully applied risk mitigation strategy requires coordination of short-term and long-term mitigation measures and thus an effective coordination of emergency management and spatial planning. Several actors are involved in risk management and should consequently be linked throughout the whole risk management cycle. However, these actors, partly because of a historically fragmented administrative system, are hardly connected to each other, with spatial planning only having a negligible role compared to other actors1, a problem to which Young (2002) referred to as the "problem of interplay". In contrast, information transfer and decision-taking happen at the same time and are not coordinated among different actors. This applies to the prevention and preparedness phase as well as to the recovery phase, which basically constitutes the prevention phase for the next disaster2. Since investments in both risk prevention and emergency preparedness and response are considered necessary, a better coordination of the two approaches is required. In this regard, Decision Support Systems (DSS) can be useful in order to provide support in the decision-making aspect of risk management. The research work currently undertaken examines the problem of interplay in the four case study areas of the Marie Curie ITN, CHANGES3. The link between different risk management actors will be explored by means of exploratory questionnaires and interviews with government agencies, local administrations, community and research organizations on each study site. First results provided will address the general role of spatial planning in risk management. Additionally, preliminary observations are made in regard to the coordination of emergency preparedness and long-term spatial planning activities. The observations consider that integration facilitates proactive strategies that aim at preventing disaster occurrence and promote interaction between involved parties. Finally, consideration is given to the potential use of a DSS tool to cover both aspects of spatial planning and emergency management in the risk management cycle.
Validation of instrumentation to monitor dynamic performance of olympic weightlifters.
Bruenger, Adam J; Smith, Sarah L; Sands, William A; Leigh, Michael R
2007-05-01
The purpose of this study was to validate the accuracy and reliability of the Weightlifting Video Overlay System (WVOS) used by coaches and sport biomechanists at the United States Olympic Training Center. Static trials with the bar set at specific positions and dynamic trials of a power snatch were performed. Static and dynamic values obtained by the WVOS were compared with values obtained by tape measure and standard video kinematic analysis. Coordinate positions (horizontal [X] and vertical [Y]) were compared on both ends (left and right) of the bar. Absolute technical error of measurement between WVOS and kinematic values were calculated (0.97 cm [left X], 0.98 cm [right X], 0.88 cm [left Y], and 0.53 cm [right Y]) for the static data. Pearson correlations for all dynamic trials exceeded r = 0.88. The greatest discrepancies between the 2 measuring systems were found to occur when there was twisting of the bar during the performance. This error was probably due to the location on the bar where the coordinates were measured. The WVOS appears to provide accurate position information when compared with standard kinematics; however, care must be taken in evaluating position measurements if there is a significant amount of twisting in the movement. The WVOS appears to be reliable and valid within reasonable error limits for the determination of weightlifting movement technique.
NASA Technical Reports Server (NTRS)
Casas, J. C.; Campbell, S. A.
1981-01-01
The applicability of the gas filter correlation radiometer (GFCR) to the measurement of tropospheric carbon monoxide gas was investigated. An assessment of the GFRC measurement system to a regional measurement program was conducted through extensive aircraft flight-testing of several versions of the GFRC. Investigative work in the following areas is described: flight test planning and coordination, acquisition of verifying CO measurements, determination and acquisition of supporting meteorological data requirements, and development of supporting computational software.
NASA Technical Reports Server (NTRS)
Avis, L. M.
1976-01-01
Tensor methods are used to express the continuum equations of motion in general curvilinear, moving, and deforming coordinate systems. The space-time tensor formulation is applicable to situations in which, for example, the boundaries move and deform. Placing a coordinate surface on such a boundary simplifies the boundary condition treatment. The space-time tensor formulation is also applicable to coordinate systems with coordinate surfaces defined as surfaces of constant pressure, density, temperature, or any other scalar continuum field function. The vanishing of the function gradient components along the coordinate surfaces may simplify the set of governing equations. In numerical integration of the equations of motion, the freedom of motion of the coordinate surfaces provides a potential for enhanced resolution of the continuum field function. An example problem of an incompressible, inviscid fluid with a top free surface is considered, where the surfaces of constant pressure (including the top free surface) are coordinate surfaces.
NASA Astrophysics Data System (ADS)
Nitschke, Naomi; Atkovska, Kalina; Hub, Jochen S.
2016-09-01
Molecular dynamics simulations are capable of predicting the permeability of lipid membranes for drug-like solutes, but the calculations have remained prohibitively expensive for high-throughput studies. Here, we analyze simple measures for accelerating potential of mean force (PMF) calculations of membrane permeation, namely, (i) using smaller simulation systems, (ii) simulating multiple solutes per system, and (iii) using shorter cutoffs for the Lennard-Jones interactions. We find that PMFs for membrane permeation are remarkably robust against alterations of such parameters, suggesting that accurate PMF calculations are possible at strongly reduced computational cost. In addition, we evaluated the influence of the definition of the membrane center of mass (COM), used to define the transmembrane reaction coordinate. Membrane-COM definitions based on all lipid atoms lead to artifacts due to undulations and, consequently, to PMFs dependent on membrane size. In contrast, COM definitions based on a cylinder around the solute lead to size-independent PMFs, down to systems of only 16 lipids per monolayer. In summary, compared to popular setups that simulate a single solute in a membrane of 128 lipids with a Lennard-Jones cutoff of 1.2 nm, the measures applied here yield a speedup in sampling by factor of ˜40, without reducing the accuracy of the calculated PMF.
ERIC Educational Resources Information Center
Kingsley, Chris
2012-01-01
This executive summary describes highlights from the report, "Building Management Information Systems to Coordinate Citywide Afterschool Programs: A Toolkit for Cities." City-led efforts to build coordinated systems of afterschool programming are an important strategy for improving the health, safety and academic preparedness of children…
ERIC Educational Resources Information Center
Braunstein, Jean; Janky, James M.
This paper describes the network coordination for the Health, Education, Telecommunications (HET) system. Specifically, it discusses HET network performance as a function of a specially-developed coordination system which was designed to link terrestrial equipment to satellite operations centers. Because all procedures and equipment developed for…
Ferrari, Lynne R; Ziniel, Sonja I; Antonelli, Richard C
2016-03-01
The relationship of care coordination activities and outcomes to resource utilization and personnel costs has been evaluated for a number of pediatric medical home practices. One of the first tools designed to evaluate the activities and outcomes for pediatric care coordination is the Care Coordination Measurement Tool (CCMT). It has become widely used as an instrument for health care providers in both primary and subspecialty care settings. This tool enables the user to stratify patients based on acuity and complexity while documenting the activities and outcomes of care coordination. We tested the feasibility of adapting the CCMT to a pediatric surgical population at Boston Children's Hospital. The tool was used to assess the preoperative care coordination activities. Care coordination activities were tracked during the interval from the date the patient was scheduled for a surgical or interventional procedure through the day of the procedure. A care coordination encounter was defined as any task, whether face to face or not, supporting the development or implementation of a plan of care. Data were collected to enable analysis of 5675 care coordination encounters supporting the care provided to 3406 individual surgical cases (patients). The outcomes of care coordination, as documented by the preoperative nursing staff, included the elaboration of the care plan through patient-focused communication among specialist, facilities, perioperative team, and primary care physicians in 80.5% of cases. The average time spent on care coordination activities increased incrementally by 30 minutes with each additional care coordination encounter for a surgical case. Surgical cases with 1 care coordination encounter took an average of 35.7 minutes of preoperative care coordination, whereas those with ≥4 care coordination encounters reported an average of 121.6 minutes. We successfully adapted and implemented the CCMT for a pediatric surgical population and measured nonface-to-face, nonbillable encounters performed by perioperative nursing staff. The care coordination activities integrated into the preoperative process include elaboration of care plans and identification and remediation of discrepancies. Capturing the activities and outcomes of care coordination for preoperative care provides a framework for quality improvement and enables documentation of the value of nonface-to-face perioperative nursing encounters that comprise care coordination.
Thormar, Sigridur B.; Juen, Barbara; Ajdukovic, Dean; Newlove-Eriksson, Lindy; Olff, Miranda
2018-01-01
Disasters can have an enormous impact on the health and well-being of those affected. Internationally, governments and service providers are often challenged to address complex psychosocial problems. Ideally, the potentially broad range of support activities include a coherent, high-quality mental health and psychosocial support (MHPSS) programme. We present a theory-driven quantitative analysis of the quality of 40 MHPSS programmes, mostly implemented in European disaster settings. The objective is to measure quality domains recognized as relevant in the literature and to empirically test associations. During the EU project “Operationalizing Psychosocial Support in Crisis” (OPSIC) an evaluation survey was designed and developed for this purpose and completed by 40 MHPSS programme coordinators involved in different mass emergencies and disasters. We analysed the survey data in two steps. Firstly, we used the data to operationalize quality domains of a MHPSS programme, tested constructs and assessed their internal consistency reliability. A total of 26 out of 44 survey items clustered into three of the four domains identified within the theoretical framework: “planning and delivery system” (Cronbach’s alpha 0.82); “general evaluation criteria” (Cronbach’s alpha 0.82); and “essential psychosocial principles” (Cronbach’s alpha 0.75). “Measures and interventions applied”, theoretically a potential fourth domain, could not be confirmed to empirically cluster together. Secondly, several models with associations between domains and measures and interventions were tested and compared. The model with the best fit suggests that in MHPSS programmes with a higher planning and delivery systems score, a larger number of measures and interventions from evidence-informed guidelines are applied. In such programmes, coordinators are more positive about general evaluation criteria and the realization of essential psychosocial principles. Moreover, the analyses showed that some measures and interventions are more likely to be applied in programmes with more evolved planning and delivery systems, yet for most measures and interventions the likelihood of being applied is not linked to planning and delivery system status, nor to coordinator perceptions concerning psychosocial principles and evaluation criteria. Further research is necessary to validate and expand the findings and to learn more about success factors and obstacles for MHPSS programme implementation. PMID:29489888
Medial orbital wall landmarks in three different North American populations.
Mehta, Milap P; Perry, Julian D
2015-04-01
We sought to measure the medial orbital wall foramina distances in two previously unstudied populations, to describe a new bony medial wall feature, and to validate the accuracy of a new coordinate measurement device within the orbit. Dried, well-preserved, complete human skulls without orbital defects were studied. Age, gender, birthplace, ethnicity, and laterality of the orbit were recorded for each skull. Supranumerary ethmoidal foramina were recorded, and the fronto-ethmoidal groove depth was measured. The distances between the anterior lacrimal crest (ALC) - anterior ethmoidal foramen (AEF), AEF - posterior ethmoidal foramen (PEF), and PEF - optic canal (OC) were measured first by surgical ruler and wire and then by the Microscribe coordinate measurement device. One hundred and forty-six orbits were studied. Fifty-seven orbits were of European or Caucasian descent, 68 orbits of African American descent, 2 orbits of West African descent, 11 orbits of Eskimo descent, and 8 orbits of unknown origin. No significant differences existed between the manual and Microscribe measurements for the ALC-AEF, AEF-PEF, and PEF-OF distances (p < 0.0001). A significant frontoethmoidal groove was observed in 27/146 (19%) orbits, in 6/57 (11%) Caucasian orbits, in 17/70 (24%) African American orbits, and in 4/11 (36%) Eskimo orbits. Supranumerary ethmoidal foramina were found in 50/146 orbits (34.2%) and in 17/27 (63%) orbits with a significant frontoethmoidal grooves. No significant differences in medial wall foramina distances exist between African American and Caucasian orbits; however, a frontoethmoidal groove occurs more commonly in African American orbits. This groove often occurs in the presence of supernumerary ethmoidal foramina. The Microscribe coordinate measurement system represents a valid tool to measure distances within the orbit.
A Trade Study of Thermosphere Empirical Neutral Density Models
2014-08-01
n,m = Degree and order, respectively ′ = Geocentric latitude Approved for public release; distribution is unlimited. 2 λ = Geocentric ...coordinate. The ECI coordinate system also known as the Approved for public release; distribution is unlimited. 3 geocentric equatorial system has...seconds for numerical integration. The EGM96 model specifies V in the Earth-Center, Earth-Fixed (ECEF) coordinate frame, a geocentric coordinate
Relation between coordinate systems describing the dynamics of a loaded Stewart platform
NASA Astrophysics Data System (ADS)
Petrova, V. I.
2018-05-01
The paper puts forward formulae for transformation of coordinates in three coordinate frames used for the study of motion of a loaded Stewart platform, which is the central mechanism of the dynamic bench. A new method for finding the law of variation of coordinates is proposed. This method depends on solving the problem-specific system of differential equations.
30 CFR 250.905 - How do I get approval for the installation, modification, or repair of my platform?
Code of Federal Regulations, 2011 CFR
2011-07-01
... four copies. (b) Location plat Latitude and longitude coordinates, Universal Mercator grid-system coordinates, state plane coordinates in the Lambert or Transverse Mercator Projection System, and distances in...
Lai, WeiJen; Midorikawa, Yoshiyuki; Kanno, Zuisei; Takemura, Hiroshi; Suga, Kazuhiro; Soga, Kohei; Ono, Takashi; Uo, Motohiro
2016-12-01
We developed a device to evaluate the orthodontic force applied by systems requiring high operability. A life-sized, two-tooth model was designed, and the measurements were performed using a custom-made jointed attachment, referred to as an "action stick", to allow clearance for the oversized six-axis sensors. This tooth-sensor apparatus was accurately calibrated, and the error was limited. Vector analysis and rotating coordinate transformation were required to derive the force and moment at the tooth from the sensor readings. The device was then used to obtain measurements of the force and moment generated by the V-bend system. Our device was effective, providing results that were consistent with those of previous studies. This measurement device can be manufactured with force sensors of any size, and it can also be expanded to models with any number of teeth.
Mapping gray-scale image to 3D surface scanning data by ray tracing
NASA Astrophysics Data System (ADS)
Li, Peng; Jones, Peter R. M.
1997-03-01
The extraction and location of feature points from range imaging is an important but difficult task in machine vision based measurement systems. There exist some feature points which are not able to be detected from pure geometric characteristics, particularly in those measurement tasks related to the human body. The Loughborough Anthropometric Shadow Scanner (LASS) is a whole body surface scanner based on structured light technique. Certain applications of LASS require accurate location of anthropometric landmarks from the scanned data. This is sometimes impossible from existing raw data because some landmarks do not appear in the scanned data. Identification of these landmarks has to resort to surface texture of the scanned object. Modifications to LASS were made to allow gray-scale images to be captured before or after the object was scanned. Two-dimensional gray-scale image must be mapped to the scanned data to acquire the 3D coordinates of a landmark. The method to map 2D images to the scanned data is based on the colinearity conditions and ray-tracing method. If the camera center and image coordinates are known, the corresponding object point must lie on a ray starting from the camera center and connecting to the image coordinate. By intersecting the ray with the scanned surface of the object, the 3D coordinates of a point can be solved. Experimentation has demonstrated the feasibility of the method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Zhenyu; Dagle, Jeffery E.
2008-07-31
The infrastructure of phasor measurements have evolved over the last two decades from isolated measurement units to networked measurement systems with footprints beyond individual utility companies. This is, to a great extent, a bottom-up self-evolving process except some local systems built by design. Given the number of phasor measurement units (PMUs) in the system is small (currently 70 each in western and eastern interconnections), current phasor network architecture works just fine. However, the architecture will become a bottleneck when large number of PMUs are installed (e.g. >1000~10000). The need for phasor architecture design has yet to be addressed. This papermore » reviews the current phasor networks and investigates future architectures, as related to the efforts undertaken by the North America SynchroPhasor Initiative (NASPI). Then it continues to present staged system tests to evaluate the performance of phasor networks, which is a common practice in the Western Electricity Coordinating Council (WECC) system. This is followed by field measurement evaluation and the implication of phasor quality issues on phasor applications.« less
NASA Astrophysics Data System (ADS)
Laundal, K. M.; Richmond, A. D.
2017-03-01
Geospace phenomena such as the aurora, plasma motion, ionospheric currents and associated magnetic field disturbances are highly organized by Earth's main magnetic field. This is due to the fact that the charged particles that comprise space plasma can move almost freely along magnetic field lines, but not across them. For this reason it is sensible to present such phenomena relative to Earth's magnetic field. A large variety of magnetic coordinate systems exist, designed for different purposes and regions, ranging from the magnetopause to the ionosphere. In this paper we review the most common magnetic coordinate systems and describe how they are defined, where they are used, and how to convert between them. The definitions are presented based on the spherical harmonic expansion coefficients of the International Geomagnetic Reference Field (IGRF) and, in some of the coordinate systems, the position of the Sun which we show how to calculate from the time and date. The most detailed coordinate systems take the full IGRF into account and define magnetic latitude and longitude such that they are constant along field lines. These coordinate systems, which are useful at ionospheric altitudes, are non-orthogonal. We show how to handle vectors and vector calculus in such coordinates, and discuss how systematic errors may appear if this is not done correctly.
Central tracker for BM@N experiment based on double side Si-microstrip detectors
NASA Astrophysics Data System (ADS)
Kovalev, Yu.; Kapishin, M.; Khabarov, S.; Shafronovskaia, A.; Tarasov, O.; Makankin, A.; Zamiatin, N.; Zubarev, E.
2017-07-01
Design of central tracker system based on Double-Sided Silicon Detectors (DSSD) for BM@N experiment is described. A coordinate plane with 10240 measuring channels, pitch adapter, reading electronics was developed. Each element was tested and assembled into a coordinate plane. The first tests of the plane with 106Ru source were carried out before installation for the BM@N experiment. The results of the study indicate that noisy channels and inefficient channels are less than 3%. In general, single clusters 87% (one group per module of consecutive strips) and 75% of clusters with a width equal to one strip.
NASA Astrophysics Data System (ADS)
Mei, F.; Dexheimer, D.; Hubbe, J. M.; deBoer, G.; Schmid, B.; Ivey, M.; Longbottom, C.; Carroll, P.
2017-12-01
The Inaugural Campaigns for ARM Research using Unmanned Systems (ICARUS) had been launched in 2016 and then the effort has been continued in 2017. ICARUS centered on Oliktok Point, Alaska focusses on developing routine operations of Unmanned Aerial Systems (UAS) and Tethered Balloon Systems (TBS). The operation routine practiced during ICARUS 2016 provided valuable guidance for the ICARUS 2017 deployment. During two intensive operation periods in 2017, a small DataHawk II UAS has been deployed to collect data for two weeks each in May and August. Coordinated with DataHawk flights, the TBS has been launched with meteorology sensors such as iMet and Tethersondes, therefore vertical profiles of the basic atmospheric state (temperature, humidity, and horizontal wind) were observed simultaneously by UAS and TBS. In addition, an aerosol payload was attached and launched with 2 TBS flights in April and 7 TBS flights in May, which include a condensation particle counter (CPC, TSI 3007) and two printed optical particle spectrometers (POPS, Handix TBS version). The two POPS were operated at different inlet temperatures. This approach provided potential measurements for aerosol optical closure in future. Measured aerosol properties include total particle number concentrations, particle size distribution, at different ambient temperature and relative humidity. Vertical profiles of atmospheric state and aerosol properties will be discussed based on the coordinated flights. Monthly variation will be assessed with data from the upcoming August flights.
48 CFR 1604.7001 - Coordination of benefits clause.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Coordination of benefits clause. 1604.7001 Section 1604.7001 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL ADMINISTRATIVE MATTERS Coordination of...
48 CFR 1604.7001 - Coordination of benefits clause.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Coordination of benefits clause. 1604.7001 Section 1604.7001 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL ADMINISTRATIVE MATTERS Coordination of...
48 CFR 1604.7001 - Coordination of benefits clause.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Coordination of benefits clause. 1604.7001 Section 1604.7001 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL ADMINISTRATIVE MATTERS Coordination of...
Fevre, Marie-Cécile; Vincent, Caroline; Picard, Julien; Vighetti, Arnaud; Chapuis, Claire; Detavernier, Maxime; Allenet, Benoît; Payen, Jean-François; Bosson, Jean-Luc; Albaladejo, Pierre
2018-02-01
Ultrasound (US) guided needle positioning is safer than anatomical landmark techniques for central venous access. Hand-eye coordination and execution time depend on the professional's ability, previous training and personal skills. Needle guidance positioning systems (GPS) may theoretically reduce execution time and facilitate needle positioning in specific targets, thus improving patient comfort and safety. Three groups of healthcare professionals (41 anaesthesiologists and intensivists, 41 residents in anaesthesiology and intensive care, 39 nurse anaesthetists) were included and required to perform 3 tasks (positioning the tip of a needle in three different targets in a silicon phantom) by using successively a conventional US-guided needle positioning and a needle GPS. We measured execution times to perform the tasks, hand-eye coordination and the number of repositioning occurrences or errors in handling the needle or the probe. Without the GPS system, we observed a significant inter-individual difference for execution time (P<0.05), hand-eye coordination and the number of errors/needle repositioning between physicians, residents and nurse anaesthetists. US training and video gaming were found to be independent factors associated with a shorter execution time. Use of GPS attenuated the inter-individual and group variability. We observed a reduced execution time and improved hand-eye coordination in all groups as compared to US without GPS. Neither US training, video gaming nor demographic personal or professional factors were found to be significantly associated with reduced execution time when GPS was used. US associated with GPS systems may improve safety and decrease execution time by reducing inter-individual variability between professionals for needle-handling procedures. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.
Annunziato, Rachel A; Baisley, Margaret C; Arrato, Nicole; Barton, Codette; Henderling, Fiona; Arnon, Ronen; Kerkar, Nanda
2013-12-01
To compare the impact of a transition coordinator on outcomes for pediatric liver transplant recipients vs a historical comparison group. To examine the utility of a transition coordinator, medication adherence, as measured by SDs of tacrolimus blood levels (Tacrolimus SD), was compared between the "transition coordinator group" (20 transplant recipients transferred between 2007 and 2012) and comparison group for 1 year before and after transfer. Measures of health care management, quality of life, and acceptability were administered to the transition coordinator group as well. A repeated measures ANOVA was used to compare adherence values between the transition coordinator group and the comparison group. During the year before transfer, for the transition coordinator group, Tacrolimus SD was 1.98 (SD = 1.05) vs 3.25 (SD = 1.19) for comparison patients, F(1,25) = 4.77, P = .04. After transfer, levels remained stable for the transition coordinator group, Tacrolimus SD = 1.88 (SD = 1.57), but increased for comparison patients, Tacrolimus SD = 4.36 (SD = 0.99), F(1,25) = 6.99, P = .01. Psychosocial outcomes remained stable during the transfer period and acceptability was high. Our findings, although limited by a small sample size, suggest that a transition coordinator is a promising method to improve this process. Copyright © 2013 Mosby, Inc. All rights reserved.
Transformation formulas relating geodetic coordinates to a tangent to Earth, plane coordinate system
NASA Technical Reports Server (NTRS)
Credeur, L.
1981-01-01
Formulas and their approximation were developed to map geodetic position to an Earth tangent plane with an airport centered rectangular coordinate system. The transformations were developed for use in a terminal area air traffic model with deterministic aircraft traffic. The exact configured vehicle's approximation equations used in their precision microwave landing system navigation experiments.
ERIC Educational Resources Information Center
Montiel, Mariana; Wilhelmi, Miguel R.; Vidakovic, Draga; Elstak, Iwan
2012-01-01
In a previous study, the onto-semiotic approach was employed to analyse the mathematical notion of different coordinate systems, as well as some situations and university students' actions related to these coordinate systems in the context of multivariate calculus. This study approaches different coordinate systems through the process of change of…
López, J M; Lombardi, M A
Time and its measurement belong to the most fundamental core of physics, and many scientific and technological advances are directly or indirectly related to time measurements. Timekeeping is essential to everyday life, and thus is the most measured physical quantity in modern societies. Time can also be measured with less uncertainty and more resolution than any other physical quantity. The measurement of time is of the utmost importance for many applications, including: global navigation satellite systems, communications networks, electric power generation, astronomy, electronic commerce, and national defense and security. This paper discusses how time is kept, coordinated, and disseminated in the Americas.
NASA Astrophysics Data System (ADS)
López, J. M.; Lombardi, M. A.
2015-10-01
Time and its measurement belong to the most fundamental core of physics, and many scientific and technological advances are directly or indirectly related to time measurements. Timekeeping is essential to everyday life, and thus is the most measured physical quantity in modern societies. Time can also be measured with less uncertainty and more resolution than any other physical quantity. The measurement of time is of the utmost importance for many applications, including: global navigation satellite systems, communications networks, electric power generation, astronomy, electronic commerce, and national defense and security. This paper discusses how time is kept, coordinated, and disseminated in the Americas.
López, J. M.; Lombardi, M. A.
2016-01-01
Time and its measurement belong to the most fundamental core of physics, and many scientific and technological advances are directly or indirectly related to time measurements. Timekeeping is essential to everyday life, and thus is the most measured physical quantity in modern societies. Time can also be measured with less uncertainty and more resolution than any other physical quantity. The measurement of time is of the utmost importance for many applications, including: global navigation satellite systems, communications networks, electric power generation, astronomy, electronic commerce, and national defense and security. This paper discusses how time is kept, coordinated, and disseminated in the Americas. PMID:26973371
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dorfman, M.H.; Morton, R.A.; Dunlap, H.F.
The following are included: objectives, overview, coordination assistance, compaction measurements on Texas Gulf Coast Sandstones and Shales; US Gulf Coast Geopressured-Geothermal Aquifer simulation, Preliminary Review of Subsidence Insurance Issues, Geopressured-Geothermal Information System, and Study of Log Derived Water Resistivity Values in Geopressured Geothermal Formations. (MHR)
Predictors of Supported Employment for Transitioning Youth with Developmental Disabilities
ERIC Educational Resources Information Center
Simonsen, Monica Lynn
2010-01-01
The Individuals with Disabilities Education Act of 2004 requires school systems to plan systematically for the transition from school to post-secondary education and/or employment and include measurable post-school goals in students' IEPs. Schools are required to coordinate activities, such as work experiences, to assist students in meeting their…
NASA Astrophysics Data System (ADS)
Prado, Yoann; Daffé, Niéli; Michel, Aude; Georgelin, Thomas; Yaacoub, Nader; Grenèche, Jean-Marc; Choueikani, Fadi; Otero, Edwige; Ohresser, Philippe; Arrio, Marie-Anne; Cartier-Dit-Moulin, Christophe; Sainctavit, Philippe; Fleury, Benoit; Dupuis, Vincent; Lisnard, Laurent; Fresnais, Jérôme
2015-12-01
Superparamagnetic nanoparticles are promising objects for data storage or medical applications. In the smallest--and more attractive--systems, the properties are governed by the magnetic anisotropy. Here we report a molecule-based synthetic strategy to enhance this anisotropy in sub-10-nm nanoparticles. It consists of the fabrication of composite materials where anisotropic molecular complexes are coordinated to the surface of the nanoparticles. Reacting 5 nm γ-Fe2O3 nanoparticles with the [CoII(TPMA)Cl2] complex (TPMA: tris(2-pyridylmethyl)amine) leads to the desired composite materials and the characterization of the functionalized nanoparticles evidences the successful coordination--without nanoparticle aggregation and without complex dissociation--of the molecular complexes to the nanoparticles surface. Magnetic measurements indicate the significant enhancement of the anisotropy in the final objects. Indeed, the functionalized nanoparticles show a threefold increase of the blocking temperature and a coercive field increased by one order of magnitude.
Silva, Pedro; Vilar, Luís; Davids, Keith; Araújo, Duarte; Garganta, Júlio
2016-01-01
Small-sided and conditioned games (SSCGs) in sport have been modelled as complex adaptive systems. Research has shown that the relative space per player (RSP) formulated in SSCGs can impact on emergent tactical behaviours. In this study we adopted a systems orientation to analyse how different RSP values, obtained through manipulations of player numbers, influenced four measures of interpersonal coordination observed during performance in SSCGs. For this purpose we calculated positional data (GPS 15 Hz) from ten U-15 football players performing in three SSCGs varying in player numbers (3v3, 4v4 and 5v5). Key measures of SSCG system behaviours included values of (1) players' dispersion, (2) teams' separateness, (3) coupling strength and time delays between participants' emerging movements, respectively. Results showed that values of participants' dispersion increased, but the teams' separateness remained identical across treatments. Coupling strength and time delay also showed consistent values across SSCGs. These results exemplified how complex adaptive systems, like football teams, can harness inherent degeneracy to maintain similar team spatial-temporal relations with opponents through changes in inter-individual coordination modes (i.e., players' dispersion). The results imply that different team behaviours might emerge at different ratios of field dimension/player numbers. Therefore, sport pedagogists should carefully evaluate the effects of changing RSP in SSCGs as a way of promoting increased or decreased pressure on players.
Rosenblum, Sara
2013-01-01
Planning ahead and organizational abilities in time and space are ingredients of high-level cognitive functions labeled as ‘Executive Functions’ (EF) required for daily activities such as writing or home management. EF deficits are considered a possible underlying brain mechanism involved in Developmental Coordination Disorders (DCD). The aim: of the study was to compare the handwriting process measures and the planning and organizational abilities in space and time of students with DCD with those of matched controls and to find whether handwriting measures can predict daily planning and organizational abilities among students with DCD. Method: 30 students diagnosed with DCD, between the ages of 24–41, and 30 age- and gender-matched controls participated in the study. They filled out the Handwriting Proficiency Screening Questionnaire (HPSQ) and the Adult Developmental Co-ordination Disorders Checklist (ADC). Furthermore, they copied a paragraph on a digitizer that is part of a computerized system Computerised Penmanship Evaluation Toll (ComPET). Results: Significant group differences were found for the HPSQ subscales scores as well as for the temporal and spatial measures of the paragraph copy task. Significant group differences were also found for the planning and organizational abilities in space and time as reflected through the ADC subscales. Significant medium correlations were found in both groups between the mean HPSQ time subscale and the ADC-B subscale mean score (r = 0.50/0.58, p < 0.05). Series of regression analyses indicated that two handwriting performance measures (mean HPSQ time subscale and mean stroke duration) predicted 19% of planning and organizational abilities as reflected through daily functions (ADC-B) [F(3, 54) = 38.37, β = 0.40, p < 0.0001]. Conclusion: The results support previous evidence about EF deficits as an underlying brain mechanism involved in motor coordination disorders, their significance as related to theoretical models of handwriting and daily function among DCD will be examined. PMID:23805113
Gietzelt, Matthias; Schnabel, Stephan; Wolf, Klaus-Hendrik; Büsching, Felix; Song, Bianying; Rust, Stefan; Marschollek, Michael
2012-05-01
One of the key problems in accelerometry based gait analyses is that it may not be possible to attach an accelerometer to the lower trunk so that its axes are perfectly aligned to the axes of the subject. In this paper we will present an algorithm that was designed to virtually align the axes of the accelerometer to the axes of the subject during walking sections. This algorithm is based on a physically reasonable approach and built for measurements in unsupervised settings, where the test persons are applying the sensors by themselves. For evaluation purposes we conducted a study with 6 healthy subjects and measured their gait with a manually aligned and a skewed accelerometer attached to the subject's lower trunk. After applying the algorithm the intra-axis correlation of both sensors was on average 0.89±0.1 with a mean absolute error of 0.05g. We concluded that the algorithm was able to adjust the skewed sensor node virtually to the coordinate system of the subject. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Station coordinates, baselines, and earth rotation from Lageos laser ranging - 1976-1984
NASA Technical Reports Server (NTRS)
Tapley, B. D.; Schultz, B. E.; Eanes, R. J.
1985-01-01
The orbit of the Lageos satellite is well suited as a reference frame for studying the rotation of the earth and the relative motion of points on the earth's crust. The satellite laser measurements can determine the location of a set of tracking stations in an appropriate terrestrial coordinate system. The motion of the earth's rotation axis relative to this system can be studied on the basis of the established tracking station locations. The present investigation is concerned with an analysis of 7.7 years of Lageos laser ranging data. In the first solution considered, the entire data span was used to adjust a single set of station positions simultaneously with orbit and earth rotation parameters. Attention is given to the accuracy of earth rotation parameters which are determined as an inherent part of the solution process.
2016-05-01
DOD ADVERTISING Better Coordination, Performance Measurement, and Oversight Needed to Help Meet Recruitment Goals...Accountability Office Highlights of GAO-16-396, a report to congressional committees May 2016 DOD ADVERTISING Better Coordination, Performance...the military, DOD requested almost $575 million in fiscal year 2017 to conduct advertising intended to increase awareness of military service and
Geary, David C; Hoard, Mary K; Nugent, Lara; Rouder, Jeffrey N
2015-12-01
The relation between performance on measures of algebraic cognition and acuity of the approximate number system (ANS) and memory for addition facts was assessed for 171 ninth graders (92 girls) while controlling for parental education, sex, reading achievement, speed of numeral processing, fluency of symbolic number processing, intelligence, and the central executive component of working memory. The algebraic tasks assessed accuracy in placing x,y pairs in the coordinate plane, speed and accuracy of expression evaluation, and schema memory for algebra equations. ANS acuity was related to accuracy of placements in the coordinate plane and expression evaluation but not to schema memory. Frequency of fact retrieval errors was related to schema memory but not to coordinate plane or expression evaluation accuracy. The results suggest that the ANS may contribute to or be influenced by spatial-numerical and numerical-only quantity judgments in algebraic contexts, whereas difficulties in committing addition facts to long-term memory may presage slow formation of memories for the basic structure of algebra equations. More generally, the results suggest that different brain and cognitive systems are engaged during the learning of different components of algebraic competence while controlling for demographic and domain general abilities. Copyright © 2015 Elsevier Inc. All rights reserved.
Guidi, G; Beraldin, J A; Ciofi, S; Atzeni, C
2003-01-01
The generation of three-dimensional (3-D) digital models produced by optical technologies in some cases involves metric errors. This happens when small high-resolution 3-D images are assembled together in order to model a large object. In some applications, as for example 3-D modeling of Cultural Heritage, the problem of metric accuracy is a major issue and no methods are currently available for enhancing it. The authors present a procedure by which the metric reliability of the 3-D model, obtained through iterative alignments of many range maps, can be guaranteed to a known acceptable level. The goal is the integration of the 3-D range camera system with a close range digital photogrammetry technique. The basic idea is to generate a global coordinate system determined by the digital photogrammetric procedure, measuring the spatial coordinates of optical targets placed around the object to be modeled. Such coordinates, set as reference points, allow the proper rigid motion of few key range maps, including a portion of the targets, in the global reference system defined by photogrammetry. The other 3-D images are normally aligned around these locked images with usual iterative algorithms. Experimental results on an anthropomorphic test object, comparing the conventional and the proposed alignment method, are finally reported.
Does it matter who organises your health care?
Dawda, Paresh; McRae, Ian S; Yen, Laurann; Islam, Md Mofizul; Bagheri, Nasser; Jowsey, Tanisha; Banfield, Michelle; Parkinson, Anne
2015-01-01
Background As the prevalence of long-term and multimorbid conditions is increasing, patients increasingly require consultations with multiple health care professionals and coordination of their care needs. Methods This study is based on a 2011 survey of older Australians which draws on sub-populations of people with diabetes aged 50 years or over, people with chronic obstructive pulmonary disease, and members of Nationals Seniors Australia. We develop a composite coordination measure and examine differences in the measure with different care coordination indicators using both descriptive and regression methods. Three categories of respondent-perceived care organisers are used: health care professionals; “no one”; and patients, their partner, relative or friend. Results Of the 2,540 survey respondents (an overall response rate of 24%), 1,865 provided information on who organised their health care, and composite coordination measures were calculated for 1,614. Multivariate analysis showed the composite score was highest where a health care professional coordinated care, followed by care organised by self or a carer, and then the group reporting no organiser. Conclusion In moving towards care coordination there are opportunities to improve the care coordination process itself, and the key enablers to improving care coordination appear to be the availability and communication of clinical information and the role of the clinical team. PMID:26150760
Spectral Rate Theory for Two-State Kinetics
NASA Astrophysics Data System (ADS)
Prinz, Jan-Hendrik; Chodera, John D.; Noé, Frank
2014-02-01
Classical rate theories often fail in cases where the observable(s) or order parameter(s) used is a poor reaction coordinate or the observed signal is deteriorated by noise, such that no clear separation between reactants and products is possible. Here, we present a general spectral two-state rate theory for ergodic dynamical systems in thermal equilibrium that explicitly takes into account how the system is observed. The theory allows the systematic estimation errors made by standard rate theories to be understood and quantified. We also elucidate the connection of spectral rate theory with the popular Markov state modeling approach for molecular simulation studies. An optimal rate estimator is formulated that gives robust and unbiased results even for poor reaction coordinates and can be applied to both computer simulations and single-molecule experiments. No definition of a dividing surface is required. Another result of the theory is a model-free definition of the reaction coordinate quality. The reaction coordinate quality can be bounded from below by the directly computable observation quality, thus providing a measure allowing the reaction coordinate quality to be optimized by tuning the experimental setup. Additionally, the respective partial probability distributions can be obtained for the reactant and product states along the observed order parameter, even when these strongly overlap. The effects of both filtering (averaging) and uncorrelated noise are also examined. The approach is demonstrated on numerical examples and experimental single-molecule force-probe data of the p5ab RNA hairpin and the apo-myoglobin protein at low pH, focusing here on the case of two-state kinetics.
NASA Technical Reports Server (NTRS)
Harm, Deborah L.; Taylor, L. C.; Bloomberg, J. J.
2007-01-01
Virtual environments (VE) offer unique training opportunities, particularly for training astronauts and preadapting them to the novel sensory conditions of microgravity. Sensorimotor aftereffects of VEs are often quite similar to adaptive sensorimotor responses observed in astronauts during and/or following space flight. The purpose of this research was to compare disturbances in sensorimotor coordination produced by dome virtual environment display and to examine the effects of exposure duration, and repeated exposures to VR systems. The current study examined disturbances in eye-head-hand (EHH) and eye-head coordination. Preliminary results will be presented. Eleven subjects have participated in the study to date. One training session was completed in order to achieve stable performance on the EHH coordination and VE tasks. Three experimental sessions were performed each separated by one day. Subjects performed a navigation and pick and place task in a dome immersive display VE for 30 or 60 min. The subjects were asked to move objects from one set of 15 pedestals to the other set across a virtual square room through a random pathway as quickly and accurately as possible. EHH coordination was measured before, immediately after, and at 1 hr, 2 hr, 4 hr and 6 hr following exposure to VR. EHH coordination was measured as position errors and reaction time in a pointing task that included multiple horizontal and vertical LED targets. Repeated measures ANOVAs were used to analyze the data. In general, we observed significant increases in position errors for both horizontal and vertical targets. The largest decrements were observed immediately following exposure to VR and showed a fairly rapid recovery across test sessions, but not across days. Subjects generally showed faster RTs across days. Individuals recovered from the detrimental effects of exposure to the VE on position errors within 1-2 hours. The fact that subjects did not significantly improve across days suggests that in order to achieve dual adaptation of EHH coordination may require more than three training sessions. These findings provide some direction for developing training schedules for VE users that facilitate adaptation, support the idea that preflight training of astronauts may serve as useful countermeasure for the sensorimotor effects of space flight, and support the idea that VEs may serve as an analog for sensorimotor effects of spaceflight.
Disease management and medication compliance.
Cohen, Joshua; Christensen, Kathyrn; Feldman, Lanna
2012-02-01
Lack of medication compliance is harmful to health care systems from both a clinical and economic perspective. This study examines the methods that disease management organizations employ to identify nonadherent patients and to measure effectiveness of compliance programs for patients with diabetes, hyperlipidemia, and cystic fibrosis. In addition, this study investigates the degree to which disease managers assume risk in their contracts, and whether compliance strategies are being coordinated with payers' use of value-based insurance design, in which patient cost sharing is a function of the relative value of pharmaceuticals. This study's findings suggest that disease management may be falling short in terms of: (a) comprehensive commitment to expert-recommended at-home devices used to self-diagnose and measure health indicators; (b) early adoption of expert-recommended new technologies to measure and improve compliance; (c) intensity of use of standard tests in outpatient clinics; (d) coordination of compliance strategies with payers' use of value-based insurance design; and (e) the proportion of risk assumed in disease management contracts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
SVIRIDOVA, V.V.; ERASTOV, V.V.; ISAEV, N.V.
2005-05-16
The MC&A Equipment and Methodological Support Strategic Plan (MEMS SP) for implementing modern MC&A equipment and methodologies at Rosatom facilities has been developed within the framework of the U.S.-Russian MPC&A Program. This plan developed by the Rosatom's Russian MC&A Equipment and Methodologies (MEM) Working Group and is coordinated by that group with support and coordination provided by the MC&A Measurements Project, Office of National Infrastructure and Sustainability, US DOE. Implementation of different tasks of the MEMS Strategic Plan is coordinated by Rosatom and US-DOE in cooperation with different U.S.-Russian MC&A-related working groups and joint site project teams. This cooperation allowsmore » to obtain and analyze information about problems, current needs and successes at Rosatom facilities and facilitates solution of the problems, satisfying the facilities' needs and effective exchange of expertise and lessons learned. The objective of the MEMS Strategic Plan is to enhance effectiveness of activities implementing modern equipment and methodologies in the Russian State MC&A system. These activities are conducted within the joint Russian-US MPC&A program aiming at reduction of possibility for theft or diversion of nuclear materials and enhancement of control of nuclear materials.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frank, R.N.
1990-02-28
The Inspection Shop at Lawrence Livermore Lab recently purchased a Sheffield Apollo RS50 Direct Computer Control Coordinate Measuring Machine. The performance of the machine was specified to conform to B89 standard which relies heavily upon using the measuring machine in its intended manner to verify its accuracy (rather than parametric tests). Although it would be possible to use the interactive measurement system to perform these tasks, a more thorough and efficient job can be done by creating Function Library programs for certain tasks which integrate Hewlett-Packard Basic 5.0 language and calls to proprietary analysis and machine control routines. This combinationmore » provides efficient use of the measuring machine with a minimum of keyboard input plus an analysis of the data with respect to the B89 Standard rather than a CMM analysis which would require subsequent interpretation. This paper discusses some characteristics of the Sheffield machine control and analysis software and my use of H-P Basic language to create automated measurement programs to support the B89 performance evaluation of the CMM. 1 ref.« less
Lemma, Habtamu Regassa; Singh, Rajwinder; Kaur, Navjot
2015-01-01
Coordination of different business activities among units becomes vital as organizations pay much attention to their core activities. Thus, their fruitfulness constantly relies on their capacity to coordinate their internal and external activities in the supply chain outside their own boundaries. Giving consideration to these obvious reasons, this paper aims to investigate the determinants of supply chain coordination of milk and dairy industries. The data were collected from 330 milk suppliers, processors, and retailers in the central part of Ethiopia. The structural equation modeling has been employed to develop the structural relationship between key constructs and measured variables. In total, 15 measured variables for coordination in the supply chain have been identified. These are further grouped into four factors namely, non-price coordination, price coordination, relationships and product development decision. It has been observed that the implementation of these factors could maximize the coordination linkage among supply chain members. Thus, dairy sectors should take the identified coordination factors into account in each of their business dealings.
Care Coordination for the Chronically Ill: Understanding the Patient's Perspective
Maeng, Daniel D; Martsolf, Grant R; Scanlon, Dennis P; Christianson, Jon B
2012-01-01
Objective To identify factors associated with perception of care coordination problems among chronically ill patients. Methods Patient-level data were obtained from a random-digit dial telephone survey of adults with chronic conditions. The survey measured respondents' self-report of care coordination problems and level of patient activation, using the Patient Activation Measure (PAM-13). Logistic regression was used to assess association between respondents' self-report of care coordination problems and a set of patient characteristics. Results Respondents in the highest activation stage had roughly 30–40 percent lower odds of reporting care coordination problems compared to those in the lowest stage (p < .01). Respondents with multiple chronic conditions were significantly more likely to report coordination problems than those with hypertension only. Respondents' race/ethnicity, employment, insurance status, income, and length of illness were not significantly associated with self-reported care coordination problems. Conclusion We conclude that patient activation and complexity of chronic illness are strongly associated with patients' self-report of care coordination problems. Developing targeted strategies to improve care coordination around these patient characteristics may be an effective way to address the issue. PMID:22985032
48 CFR 1604.7001 - Coordination of benefits clause.
Code of Federal Regulations, 2011 CFR
2011-10-01
... FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL ADMINISTRATIVE MATTERS Coordination of Benefits 1604.7001 Coordination of benefits clause. OPM expects all FEHBP plans to coordinate benefits... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Coordination of benefits...
48 CFR 1604.7001 - Coordination of benefits clause.
Code of Federal Regulations, 2012 CFR
2012-10-01
... FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL ADMINISTRATIVE MATTERS Coordination of Benefits 1604.7001 Coordination of benefits clause. OPM expects all FEHBP plans to coordinate benefits... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Coordination of benefits...
Users manual for coordinate generation code CRDSRA
NASA Technical Reports Server (NTRS)
Shamroth, S. J.
1985-01-01
Generation of a viable coordinate system represents an important component of an isolated airfoil Navier-Stokes calculation. The manual describes a computer code for generation of such a coordinate system. The coordinate system is a general nonorthogonal one in which high resolution normal to the airfoil is obtained in the vicinity of the airfoil surface, and high resolution along the airfoil surface is obtained in the vicinity of the airfoil leading edge. The method of generation is a constructive technique which leads to a C type coordinate grid. The method of construction as well as input and output definitions are contained herein. The computer code itself as well as a sample output is being submitted to COSMIC.
Leadership in multiteam systems.
DeChurch, Leslie A; Marks, Michelle A
2006-03-01
This study examined 2 leader functions likely to be instrumental in synchronizing large systems of teams (i.e., multiteam systems [MTSs]). Leader strategizing and coordinating were manipulated through training, and effects on functional leadership, interteam coordination, and MTS performance were examined. Three hundred eighty-four undergraduate students participated in a laboratory simulation modeling a 3-team MTS performing an F-22 battle simulation task (N = 64 MTSs). Results indicate that both leader training manipulations improved functional leadership and interteam coordination and that functional leader behavior was positively related to MTS-level performance. Functional leadership mediated the effects of both types of training on interteam coordination, and interteam coordination fully mediated the effect of MTS leadership on MTS performance.
A phantom evaluation of a stereo-vision surface imaging system for radiotherapy patient setup
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bert, Christoph; Metheany, Katherine G.; Doppke, Karen
2005-09-15
External beam irradiation requires precise positioning of the target relative to the treatment planning coordinate system. A three-dimensional (3D) surface imaging system for patient positioning has recently been installed in one of our linear accelerator (linac) rooms. The device utilizes close-range photogrammetry to generate a 3D model of the patient's surface. This geometric model can be made to look like a digital camera image if wrapped with a gray-level image (texture mapping) that shows surface coloration. The system is calibrated to the linac coordinate system and has been designed as a patient setup device. To reproduce patient position in fractionatedmore » radiotherapy, the daily patient surface model is registered to a previously recorded reference surface. Using surface registration, the system calculates the rigid-body transformation that minimizes the distance between the treatment and the reference surface models in a region-of-interest (ROI). This transformation is expressed as a set of new couch coordinates at which the patient position best matches with the reference data. If respiratory motion is a concern, the surface can be obtained with a gated acquisition at a specified phase of the respiratory cycle. To analyze the accuracy of the system, we performed several experiments with phantoms to assess stability, alignment accuracy, precision of the gating function, and surface topology. The reproducibility of surface measurements was tested for periods up to 57 h. Each recorded frame was registered to the reference surface to calculate the required couch adjustment. The system stability over this time period was better than 0.5 mm. To measure the accuracy of the system to detect and quantify patient shift relative to a reference image, we compared the shift detected by the surface imaging system with known couch transitions in a phantom study. The maximum standard deviation was 0.75 mm for the three translational degrees of freedom, and less than 0.1 deg. for each rotation. Surface model precision was tested against computed tomography (CT)-derived surface topology. The root-mean-square rms of the distance between the surfaces was 0.65 mm, excluding regions where beam hardening caused artifacts in the CT data. Measurements were made to test the gated acquisition mode. The time-dependent amplitude was measured with the surface imaging system and an established respiratory gating system based on infrared (IR)-marker detection. The measured motion trajectories from both systems were compared to the known trajectory of the stage. The standard deviations of the amplitude differences to the motor trajectory were 0.04 and 0.15 mm for the IR-marker system and the 3D surface imaging system, respectively. A limitation of the surface-imaging device is the frame rate of 6.5 Hz, because rapid changes of the motion trajectory cannot be detected. In conclusion, the system is accurate and sufficiently stable to be used in the clinic. The errors computed when comparing the surface model with CT geometry were submillimeter, and deviations in the alignment and gating-signal tests were of the same magnitude.« less
A computer system for the storage and retrieval of gravity data, Kingdom of Saudi Arabia
Godson, Richard H.; Andreasen, Gordon H.
1974-01-01
A computer system has been developed for the systematic storage and retrieval of gravity data. All pertinent facts relating to gravity station measurements and computed Bouguer values may be retrieved either by project name or by geographical coordinates. Features of the system include visual display in the form of printer listings of gravity data and printer plots of station locations. The retrieved data format interfaces with the format of GEOPAC, a system of computer programs designed for the analysis of geophysical data.
NASA Technical Reports Server (NTRS)
Kooi, Susan; Fenn, Marta; Ismail, Syed; Ferrare, Richard; Hair, John; Browell, Edward; Notari, Anthony; Butler, Carolyn; Burton, Sharon; Simpson, Steven
2008-01-01
Large scale distributions of ozone, water vapor, aerosols, and clouds were measured throughout the troposphere by two NASA Langley lidar systems on board the NASA DC-8 aircraft as part of the Tropical Composition, Cloud, and Climate Coupling Experiment (TC4) over Central and South America and adjacent oceans in the summer of 2007. Special emphasis was placed on the sampling of convective outflow and transport, sub-visible cirrus clouds, boundary layer aerosols, Saharan dust, volcanic emissions, and urban and biomass burning plumes. This paper presents preliminary results from this campaign, and demonstrates the value of coordinated measurements by the two lidar systems.
Aligning with physicians to regionalize services.
Fink, John
2014-11-01
When effectively designed and implemented, regionalization allows a health system to coordinate care, eliminate redundancies, reduce costs, optimize resource utilization, and improve outcomes. The preferred model to manage service lines regionally will depend on each facility's capabilities and the willingness of physicians to accept changes in clinical delivery. Health systems can overcome physicians' objections to regionalization by implementing a hospital-physician alignment structure that gives a measure of shared control in the management of the organization.
European Science Notes Information Bulletin Reports on Current European/ Middle Eastern Science
1991-12-01
50 m); innovative acoustic, substances laser, and biosensors; fluxes through the seabed, and . Biological processes real - time measurement of seabed...Woodhouse, Lowestoft, U.K. 4 r ESNIB 91-07 Title Coordinator and Partners FAX Number European River Ocean System (EROS 2000): J.M. Martin, tcole Normale...Athens, Greece; F. Voutsinou, Athens, Greece European River Ocean System (EROS 2000) - J.-M. Martin, Icole Normale Superierre, Montrouge, 33 1 46570497
Effect of Receiver Choosing on Point Positions Determination in Network RTK
NASA Astrophysics Data System (ADS)
Bulbul, Sercan; Inal, Cevat
2016-04-01
Nowadays, the developments in GNSS technique allow to determinate point positioning in real time. Initially, point positioning was determined by RTK (Real Time Kinematic) based on a reference station. But, to avoid systematic errors in this method, distance between the reference points and rover receiver must be shorter than10 km. To overcome this restriction in RTK method, the idea of setting more than one reference point had been suggested and, CORS (Continuously Operations Reference Systems) was put into practice. Today, countries like ABD, Germany, Japan etc. have set CORS network. CORS-TR network which has 146 reference points has also been established in 2009 in Turkey. In CORS-TR network, active CORS approach was adopted. In Turkey, CORS-TR reference stations covering whole country are interconnected and, the positions of these stations and atmospheric corrections are continuously calculated. In this study, in a selected point, RTK measurements based on CORS-TR, were made with different receivers (JAVAD TRIUMPH-1, TOPCON Hiper V, MAGELLAN PRoMark 500, PENTAX SMT888-3G, SATLAB SL-600) and with different correction techniques (VRS, FKP, MAC). In the measurements, epoch interval was taken as 5 seconds and measurement time as 1 hour. According to each receiver and each correction technique, means and differences between maximum and minimum values of measured coordinates, root mean squares in the directions of coordinate axis and 2D and 3D positioning precisions were calculated, the results were evaluated by statistical methods and the obtained graphics were interpreted. After evaluation of the measurements and calculations, for each receiver and each correction technique; the coordinate differences between maximum and minimum values were measured to be less than 8 cm, root mean squares in coordinate axis directions less than ±1.5 cm, 2D point positioning precisions less than ±1.5 cm and 3D point positioning precisions less than ±1.5 cm. In the measurement point, it has been concluded that VRS correction technique is generally better than other corrections techniques.
Tashman, Scott; Anderst, William
2003-04-01
Dynamic assessment of three-dimensional (3D) skeletal kinematics is essential for understanding normal joint function as well as the effects of injury or disease. This paper presents a novel technique for measuring in-vivo skeletal kinematics that combines data collected from high-speed biplane radiography and static computed tomography (CT). The goals of the present study were to demonstrate that highly precise measurements can be obtained during dynamic movement studies employing high frame-rate biplane video-radiography, to develop a method for expressing joint kinematics in an anatomically relevant coordinate system and to demonstrate the application of this technique by calculating canine tibio-femoral kinematics during dynamic motion. The method consists of four components: the generation and acquisition of high frame rate biplane radiographs, identification and 3D tracking of implanted bone markers, CT-based coordinate system determination, and kinematic analysis routines for determining joint motion in anatomically based coordinates. Results from dynamic tracking of markers inserted in a phantom object showed the system bias was insignificant (-0.02 mm). The average precision in tracking implanted markers in-vivo was 0.064 mm for the distance between markers and 0.31 degree for the angles between markers. Across-trial standard deviations for tibio-femoral translations were similar for all three motion directions, averaging 0.14 mm (range 0.08 to 0.20 mm). Variability in tibio-femoral rotations was more dependent on rotation axis, with across-trial standard deviations averaging 1.71 degrees for flexion/extension, 0.90 degree for internal/external rotation, and 0.40 degree for varus/valgus rotation. Advantages of this technique over traditional motion analysis methods include the elimination of skin motion artifacts, improved tracking precision and the ability to present results in a consistent anatomical reference frame.
NASA Technical Reports Server (NTRS)
Gnoffo, P. A.
1977-01-01
A generalized curvilinear orthogonal coordinate system is presented which can be used for approximating various axisymmetric and two-dimensional body shapes of interest to aerodynamicists. Such body shapes include spheres, ellipses, spherically capped cones, flat-faced cylinders with rounded corners, circular disks, and planetary probe vehicles. A set of transformation equations is also developed whereby a uniform velocity field approaching a body at any angle of attack can be resolved in the transformed coordinate system. The Navier-Stokes equations are written in terms of a generalized orthogonal coordinate system to show the resultant complexity of the governing equations.
Accuracy of GPS time transfer verified by closure around the world
NASA Technical Reports Server (NTRS)
Lewandowski, Wlodimierz W.; Petit, Gerard; Thomas, Claudine
1992-01-01
The precision of time transfer over intercontinental distances by the Global Positioning System common-view method, using measurements of ionospheric delays, precise ephemerides provided by the Defense Mapping Agency (DMA) and a consistent set of antenna coordinates, reaches 3 to 4 ns for a single 13-minute measurement, and decreases to 2 ns when averaging several measurements over the period of one day. It is thought that even this level of precision can be bettered by improving the ionospheric measurements, the ephemerides of satellites, and the antenna coordinates. In the same conditions, an estimation of the accuracy is attained by using three intercontinental links encircling the Earth to establish a closure condition; the three independent links should add to zero. We have computed such a closure condition over a period of 13 months using data recorded at the Paris Observatory, at the Communications Research Laboratory in Tokyo, and at the National Institute for Standards and Technology in Boulder, Colorado. The closure condition is verified to within a few nanoseconds, but a bias, varying with time, can be detected.
Protection coordination of the Kennedy Space Center electric distribution network
NASA Technical Reports Server (NTRS)
1976-01-01
A computer technique is described for visualizing the coordination and protection of any existing system of devices and settings by plotting the tripping characteristics of the involved devices on a common basis. The program determines the optimum settings of a given set of protective devices and configuration in the sense of the best expected coordinated operation of these devices. Subroutines are given for simulating time versus current characteristics of the different relays, circuit breakers, and fuses in the system; coordination index computation; protection checks; plotting; and coordination optimation.
An Analysis of the Accessibility of Earth-Approaching Asteroids.
1985-12-01
coordinate system. Outputs are the X,Y,Z coordinates of the sun in the geocentric-equatorial coordinate system. The obliquity of the ecliptic is a variable...All positions and velocities are calculated in heliocentric- ecliptic coordinates thus requiring no transformations into unusual frames of reference...tion vectors of the departure and arrival planets in the heliocentric- ecliptic reference frame. ,\\. , V I(W() - / n (16) %: ~22% .b The angle between
Measurement methods and accuracy analysis of Chang'E-5 Panoramic Camera installation parameters
NASA Astrophysics Data System (ADS)
Yan, Wei; Ren, Xin; Liu, Jianjun; Tan, Xu; Wang, Wenrui; Chen, Wangli; Zhang, Xiaoxia; Li, Chunlai
2016-04-01
Chang'E-5 (CE-5) is a lunar probe for the third phase of China Lunar Exploration Project (CLEP), whose main scientific objectives are to implement lunar surface sampling and to return the samples back to the Earth. To achieve these goals, investigation of lunar surface topography and geological structure within sampling area seems to be extremely important. The Panoramic Camera (PCAM) is one of the payloads mounted on CE-5 lander. It consists of two optical systems which installed on a camera rotating platform. Optical images of sampling area can be obtained by PCAM in the form of a two-dimensional image and a stereo images pair can be formed by left and right PCAM images. Then lunar terrain can be reconstructed based on photogrammetry. Installation parameters of PCAM with respect to CE-5 lander are critical for the calculation of exterior orientation elements (EO) of PCAM images, which is used for lunar terrain reconstruction. In this paper, types of PCAM installation parameters and coordinate systems involved are defined. Measurement methods combining camera images and optical coordinate observations are studied for this work. Then research contents such as observation program and specific solution methods of installation parameters are introduced. Parametric solution accuracy is analyzed according to observations obtained by PCAM scientifically validated experiment, which is used to test the authenticity of PCAM detection process, ground data processing methods, product quality and so on. Analysis results show that the accuracy of the installation parameters affects the positional accuracy of corresponding image points of PCAM stereo images within 1 pixel. So the measurement methods and parameter accuracy studied in this paper meet the needs of engineering and scientific applications. Keywords: Chang'E-5 Mission; Panoramic Camera; Installation Parameters; Total Station; Coordinate Conversion
Brain Interaction during Cooperation: Evaluating Local Properties of Multiple-Brain Network.
Sciaraffa, Nicolina; Borghini, Gianluca; Aricò, Pietro; Di Flumeri, Gianluca; Colosimo, Alfredo; Bezerianos, Anastasios; Thakor, Nitish V; Babiloni, Fabio
2017-07-21
Subjects' interaction is the core of most human activities. This is the reason why a lack of coordination is often the cause of missing goals, more than individual failure. While there are different subjective and objective measures to assess the level of mental effort required by subjects while facing a situation that is getting harder, that is, mental workload, to define an objective measure based on how and if team members are interacting is not so straightforward. In this study, behavioral, subjective and synchronized electroencephalographic data were collected from couples involved in a cooperative task to describe the relationship between task difficulty and team coordination, in the sense of interaction aimed at cooperatively performing the assignment. Multiple-brain connectivity analysis provided information about the whole interacting system. The results showed that averaged local properties of a brain network were affected by task difficulty. In particular, strength changed significantly with task difficulty and clustering coefficients strongly correlated with the workload itself. In particular, a higher workload corresponded to lower clustering values over the central and parietal brain areas. Such results has been interpreted as less efficient organization of the network when the subjects' activities, due to high workload tendencies, were less coordinated.
NASA Astrophysics Data System (ADS)
Leroux, B.; Cali, J.; Verdun, J.; Morel, L.; He, H.
2017-08-01
Airborne LiDAR systems require the use of Direct Georeferencing (DG) in order to compute the coordinates of the surveyed point in the mapping frame. An UAV platform does not derogate to this need, but its payload has to be lighter than this installed onboard so the manufacturer needs to find an alternative to heavy sensors and navigation systems. For the georeferencing of these data, a possible solution could be to replace the Inertial Measurement Unit (IMU) by a camera and record the optical flow. The different frames would then be processed thanks to photogrammetry so as to extract the External Orientation Parameters (EOP) and, therefore, the path of the camera. The major advantages of this method called Visual Odometry (VO) is low cost, no drifts IMU-induced, option for the use of Ground Control Points (GCPs) such as on airborne photogrammetry surveys. In this paper we shall present a test bench designed to assess the reliability and accuracy of the attitude estimated from VO outputs. The test bench consists of a trolley which embeds a GNSS receiver, an IMU sensor and a camera. The LiDAR is replaced by a tacheometer in order to survey the control points already known. We have also developped a methodology applied to this test bench for the calibration of the external parameters and the computation of the surveyed point coordinates. Several tests have revealed a difference about 2-3 centimeters between the control point coordinates measured and those already known.
Malec, J F; Buffington, A L; Moessner, A M; Degiorgio, L
2000-08-01
To evaluate initial placement and 1-year employment outcomes of a Medical/Vocational Case Coordination System (MVCCS) for persons with brain injury (BI) that provides: (1) early case identification and coordination, (2) appropriate medical and vocational rehabilitation interventions, (3) work trials, and (4) supported employment interventions including job coaching. One hundred fourteen Minnesota residents, ages 18 to 65 years, with acquired BI. Five levels of Vocational Independence Scale (VIS). Preinjury employment status (VIS) and years of education, severity of initial injury, time since injury, current impairment/disability as measured by the Rasch-analyzed Staff Mayo-Portland Adaptability Inventory (MPAI), and impaired self-awareness measured by staff rating and the difference between Staff MPAI and Survivor MPAI. At placement, 46% in independent work; 25% in transitional placements; 9% in long-term supported employment; 10% in sheltered work; and 10% not placed. At 1-year follow-up (n = 101), 53% in independent work; 19% in transitional placement; 9% in supported work; 6% in sheltered work; and 13% unemployed. Regression analyses showed time since injury and Rasch Staff MPAI predicted VIS at placement; only VIS at placement independently predicted VIS at 1-year follow-up; Rasch Staff MPAI and preinjury education level predicted time to placement. The MVCCS optimized vocational outcome after BI. Time since injury and impairment/disability best predicted vocational placement. Level of initial placement best predicted employment status at follow-up. Persons with greater disability required more extended time and more extensive rehabilitation services before placement.
Streamlining Collaborative Planning in Spacecraft Mission Architectures
NASA Technical Reports Server (NTRS)
Misra, Dhariti; Bopf, Michel; Fishman, Mark; Jones, Jeremy; Kerbel, Uri; Pell, Vince
2000-01-01
During the past two decades, the planning and scheduling community has substantially increased the capability and efficiency of individual planning and scheduling systems. Relatively recently, research work to streamline collaboration between planning systems is gaining attention. Spacecraft missions stand to benefit substantially from this work as they require the coordination of multiple planning organizations and planning systems. Up to the present time this coordination has demanded a great deal of human intervention and/or extensive custom software development efforts. This problem will become acute with increased requirements for cross-mission plan coordination and multi -spacecraft mission planning. The Advanced Architectures and Automation Branch of NASA's Goddard Space Flight Center is taking innovative steps to define collaborative planning architectures, and to identify coordinated planning tools for Cross-Mission Campaigns. Prototypes are being developed to validate these architectures and assess the usefulness of the coordination tools by the planning community. This presentation will focus on one such planning coordination too], named Visual Observation Layout Tool (VOLT), which is currently being developed to streamline the coordination between astronomical missions
Analysis of Photogrammetry Data from ISIM Mockup
NASA Technical Reports Server (NTRS)
Nowak, Maria; Hill, Mike
2007-01-01
During ground testing of the Integrated Science Instrument Module (ISIM) for the James Webb Space Telescope (JWST), the ISIM Optics group plans to use a Photogrammetry Measurement System for cryogenic calibration of specific target points on the ISIM composite structure and Science Instrument optical benches and other GSE equipment. This testing will occur in the Space Environmental Systems (SES) chamber at Goddard Space Flight Center. Close range photogrammetry is a 3 dimensional metrology system using triangulation to locate custom targets in 3 coordinates via a collection of digital photographs taken from various locations and orientations. These photos are connected using coded targets, special targets that are recognized by the software and can thus correlate the images to provide a 3 dimensional map of the targets, and scaled via well calibrated scale bars. Photogrammetry solves for the camera location and coordinates of the targets simultaneously through the bundling procedure contained in the V-STARS software, proprietary software owned by Geodetic Systems Inc. The primary objectives of the metrology performed on the ISIM mock-up were (1) to quantify the accuracy of the INCA3 photogrammetry camera on a representative full scale version of the ISIM structure at ambient temperature by comparing the measurements obtained with this camera to measurements using the Leica laser tracker system and (2), empirically determine the smallest increment of target position movement that can be resolved by the PG camera in the test setup, i.e., precision, or resolution. In addition, the geometrical details of the test setup defined during the mockup testing, such as target locations and camera positions, will contribute to the final design of the photogrammetry system to be used on the ISIM Flight Structure.